WorldWideScience

Sample records for gallium spect detection

  1. Gallium SPECT detection of neoplastic intravascular obstruction of the superior vena cava

    International Nuclear Information System (INIS)

    Swayne, L.C.; Kaplan, I.L.

    1989-01-01

    A rare case of an intravascular neoplastic obstruction of the superior vena cava is discussed. The lesion was detected with gallium single photon emission computed tomography (SPECT) despite a normal appearance on a concurrent radiographic CT study. A computer-generated composite SPECT-CT image confirmed the intravascular localization of the radioisotope, and a subsequent CT-guided transthoracic needle biopsy revealed a poorly differentiated adenocarcinoma

  2. Gallium-SPECT in the detection of prosthetic valve endocarditis and aortic ring abscess

    Energy Technology Data Exchange (ETDEWEB)

    O' Brien, K.; Barnes, D.; Martin, R.H.; Rae, J.R. (Department of Diagnostic Radiology, Victoria General Hospital Halifax, Nova Scotia (Canada))

    1991-09-01

    A 52-yr-old man who had a bioprosthetic aortic valve developed Staphylococcus aureus bacteremia. Despite antibiotic therapy he had persistent pyrexia and developed new conduction system disturbances. Echocardiography did not demonstrate vegetations on the valve or an abscess, but gallium scintigraphy using SPECT clearly identified a focus of intense activity in the region of the aortic valve. The presence of valvular vegetations and a septal abscess was confirmed at autopsy. Gallium scintigraphy, using SPECT, provided a useful noninvasive method for the demonstration of endocarditis and the associated valve ring abscess.

  3. Gallium-SPECT in the detection of prosthetic valve endocarditis and aortic ring abscess

    International Nuclear Information System (INIS)

    O'Brien, K.; Barnes, D.; Martin, R.H.; Rae, J.R.

    1991-01-01

    A 52-yr-old man who had a bioprosthetic aortic valve developed Staphylococcus aureus bacteremia. Despite antibiotic therapy he had persistent pyrexia and developed new conduction system disturbances. Echocardiography did not demonstrate vegetations on the valve or an abscess, but gallium scintigraphy using SPECT clearly identified a focus of intense activity in the region of the aortic valve. The presence of valvular vegetations and a septal abscess was confirmed at autopsy. Gallium scintigraphy, using SPECT, provided a useful noninvasive method for the demonstration of endocarditis and the associated valve ring abscess

  4. Radiopharmaceuticals for SPECT cancer detection

    Energy Technology Data Exchange (ETDEWEB)

    Chernov, V. I., E-mail: chernov@oncology.tomsk.ru; Medvedeva, A. A., E-mail: tickayaAA@oncology.tomsk.ru; Zelchan, R. V., E-mail: r.zelchan@yandex.ru; Sinilkin, I. G., E-mail: sinilkinig@oncology.tomsk.ru [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation); Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Stasyuk, E. S.; Larionova, L. A. [Tomsk Polytechnic University, Lenin Avenue 30, Tomsk, 634050 (Russian Federation); Slonimskaya, E. M.; Choynzonov, E. L. [Tomsk Cancer Research Institute, Kooperativny Street 5, Tomsk, 634050 (Russian Federation)

    2016-08-02

    The purpose of the study was to assess the efficacy of single photon emission computed tomography (SPECT) with {sup 199}Tl and {sup 99}mTc-MIBI in the detection of breast, laryngeal and hypopharyngeal cancers. A total of 220 patients were included into the study: 120 patients with breast lesions (100 patients with breast cancer and 20 patients with benign breast tumors) and 100 patients with laryngeal/hypopharyngeal diseases (80 patients with laryngeal/hypopharyngeal cancer and 20 patients with benign laryngeal/hypopharyngeal lesions). No abnormal {sup 199}Tl uptake was seen in all patients with benign breast and laryngeal lesions, indicating a 100% specificity of {sup 199}Tl SPECT. In the breast cancer patients, the increased {sup 199}Tl uptake in the breast was visualized in 94.8% patients, {sup 99m}Tc-MIBI—in 93.4% patients. The increased {sup 199}Tl uptake in axillary lymph nodes was detected in 60% patients, and {sup 99m}Tc-MIBI—in 93.1% patients. In patients with laryngeal/hypopharyngeal cancer, the sensitivity of SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI was 95%. The {sup 199}Tl SPECT sensitivity in identification of regional lymph node metastases in the patients with laryngeal/hypopharyngeal cancer was 75% and the {sup 99m}Tc-MIBI SPECT sensitivity was 17%. The data obtained showed that SPECT with {sup 199}Tl and {sup 99m}Tc-MIBI can be used as one of the additional imaging methods in detection of tumors.

  5. Gallium

    Science.gov (United States)

    Foley, Nora K.; Jaskula, Brian W.; Kimball, Bryn E.; Schulte, Ruth F.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Gallium is a soft, silvery metallic element with an atomic number of 31 and the chemical symbol Ga. Gallium is used in a wide variety of products that have microelectronic components containing either gallium arsenide (GaAs) or gallium nitride (GaN). GaAs is able to change electricity directly into laser light and is used in the manufacture of optoelectronic devices (laser diodes, light-emitting diodes [LEDs], photo detectors, and solar cells), which are important for aerospace and telecommunications applications and industrial and medical equipment. GaAs is also used in the production of highly specialized integrated circuits, semiconductors, and transistors; these are necessary for defense applications and high-performance computers. For example, cell phones with advanced personal computer-like functionality (smartphones) use GaAs-rich semiconductor components. GaN is used principally in the manufacture of LEDs and laser diodes, power electronics, and radio-frequency electronics. Because GaN power transistors operate at higher voltages and with a higher power density than GaAs devices, the uses for advanced GaN-based products are expected to increase in the future. Gallium technologies also have large power-handling capabilities and are used for cable television transmission, commercial wireless infrastructure, power electronics, and satellites. Gallium is also used for such familiar applications as screen backlighting for computer notebooks, flat-screen televisions, and desktop computer monitors.Gallium is dispersed in small amounts in many minerals and rocks where it substitutes for elements of similar size and charge, such as aluminum and zinc. For example, gallium is found in small amounts (about 50 parts per million) in such aluminum-bearing minerals as diaspore-boehmite and gibbsite, which form bauxite deposits, and in the zinc-sulfide mineral sphalerite, which is found in many mineral deposits. At the present time, gallium metal is derived mainly as a

  6. Neutron detection using boron gallium nitride semiconductor material

    Directory of Open Access Journals (Sweden)

    Katsuhiro Atsumi

    2014-03-01

    Full Text Available In this study, we developed a new neutron-detection device using a boron gallium nitride (BGaN semiconductor in which the B atom acts as a neutron converter. BGaN and gallium nitride (GaN samples were grown by metal organic vapor phase epitaxy, and their radiation detection properties were evaluated. GaN exhibited good sensitivity to α-rays but poor sensitivity to γ-rays. Moreover, we confirmed that electrons were generated in the depletion layer under neutron irradiation. This resulted in a neutron-detection signal after α-rays were generated by the capture of neutrons by the B atoms. These results prove that BGaN is useful as a neutron-detecting semiconductor material.

  7. Small hepatocellular carcinomas in chronic liver disease: Detection with SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kudo, M.; Hirasa, M.; Takakuwa, H.; Ibuki, Y.; Fujimi, K.; Miyamura, M.; Tomita, S.; Komori, H.; Todo, A.; Kitaura, Y.

    1986-06-01

    Single-photon emission computed tomography (SPECT) performed using a rotating gamma camera was compared with ..cap alpha../sub 1/-fetoprotein (AFP) assay, conventional liver scintigraphy, ultrasound (US) imaging, computed tomography (CT), and selective celiac angiography in 40 patients with a total of 50 small hepatocellular carcinomas (HCCs;<5 cm). The detection rates of US and CT were determined on an initial screening study and on a second, more precisely focused study. The detection rate of small HCCs by the various modalities was as follows: AFP, 13%; liver scintigraphy, 36%; SPECT, 72%; initial screening US, 80%; second, more precise US studies, 94%; initial screening CT, 64%; second, more precise CT study, 82%; angiography, 88%. Although SPECT was inferior to the initial screening US examination in detecting HCCs less than 2 cm in size, its sensitivity was identical to that of the initial screening US study for detecting HCCs of 2-5 cm. The combination of SPECT and US was an excellent method for the early detection of HCCs, yielding a detection rate of 94%.

  8. Ocular melanoma: Detection using iodine-123-iodoamphetamine and SPECT imaging

    International Nuclear Information System (INIS)

    Dewey, S.H.; Leonard, J.C.

    1990-01-01

    Uptake of iodine-123-iodoamphetamine has been demonstrated in malignant melanoma using planar imaging techniques and has been used to detect an ocular melanoma at 12 hr postinjection. Using SPECT technique, an ocular melanoma is identified in a 64-yr-old male at 1 hr postinjection

  9. 67Gallium • the D,etection and Localization

    African Journals Online (AJOL)

    1971-12-11

    Dec 11, 1971 ... gallium and its compounds was first aroused when it was noted that this element is contained .... MATERIALS AND METHODS. ;;'Gallium citrate was .... another in a patient with a pathological fracture of the right humerus that ...

  10. Infective endocarditis detection through SPECT/CT images digital processing

    Science.gov (United States)

    Moreno, Albino; Valdés, Raquel; Jiménez, Luis; Vallejo, Enrique; Hernández, Salvador; Soto, Gabriel

    2014-03-01

    Infective endocarditis (IE) is a difficult-to-diagnose pathology, since its manifestation in patients is highly variable. In this work, it was proposed a semiautomatic algorithm based on SPECT images digital processing for the detection of IE using a CT images volume as a spatial reference. The heart/lung rate was calculated using the SPECT images information. There were no statistically significant differences between the heart/lung rates values of a group of patients diagnosed with IE (2.62+/-0.47) and a group of healthy or control subjects (2.84+/-0.68). However, it is necessary to increase the study sample of both the individuals diagnosed with IE and the control group subjects, as well as to improve the images quality.

  11. Potentiometric end point detection in the EDTA titrimetric determination of gallium

    International Nuclear Information System (INIS)

    Gopinath, N.; Renuka, M.; Aggarwal, S.K.

    2001-01-01

    Gallium is titrated in presence of known amount of Fe (III) with EDTA in HNO 3 solution at pH 2 to 3. The end point is detected potentiometrically employing a bright platinum wire - saturated calomel (SCE) reference electrode system, the redox couple being Fe (III) / Fe (II). Since Fe (III) is also titrated by EDTA, it is, therefore, subtracted from titre value to get the EDTA equivalent to gallium only. Precision and accuracy 0.2 to 0.4% was obtained in the results of gallium in the range of 8 to 2 mg. (author)

  12. Concordance between myocardial perfusion scan assessed by SPECT and fractional flow reserve findings for detection of significant ischemia

    Directory of Open Access Journals (Sweden)

    Morteza Safi

    2016-09-01

    Conclusion: FFR and MPI with SPECT techniques showed significant concordance for detection of myocardial ischemia, regardless of the type of diseased coronary arteries. In this context, SPECT has high sensitivity and NPV for detection of ischemia compared with FFR.

  13. Myocardial scintigraphy with gallium-67 in the detection of cardiac acute rejection

    International Nuclear Information System (INIS)

    Meneguetti, J.C.

    1990-01-01

    In order to evaluate the myocardial scintigraphy with Gallium-67 potentiality in the detection of acute rejection phenomenon, 105 studies were performed in 20 patients after they had a heart transplantation. The scintigraphic images were obtained by a conventional camera-computer system. These images were acquired 48 hours after all the patients were given an intravenous injection of 111 MBq of Gallium-67 Citrate. The biopsies were done according to the Mason technique and the histological analysis followed the Billingham standards. (author)

  14. SPECT versus planar bone radionuclide imaging in the detection of spondylolysis

    International Nuclear Information System (INIS)

    Whitten, C.G.; El-Khoury, G.Y.; Chang, P.J.; Seabold, J.E.; Found, E.M.; Renfrew, D.L.

    1991-01-01

    This paper evaluates the relative performance and ease of interpretation of SPECT versus planar radionuclide bone imaging in the detection of spondylolysis. The authors studied all patients presenting with back pain suggestive of spondylolysis from November 1989 to January 1991 who underwent bone scanning; patients underwent both planar and SPECT imaging. The planar and SPECT images were randomly mixed and independently interpreted by four observers for presence or absence of spondylolysis and ease of interpretation for each scan. Receiver operating characteristic (ROC) and analysis of variance (ANOVA) were used. Of 72 patients, 19 had confirmed spondylolysis, and 53 did not. While ROC analysis showed that SPECT performed slightly better than planar imaging for all four observers, the difference was not statistically significant. ANOVA results suggest that planar imaging was significantly easier to use than SPECT and that ease of use was strongly correlated with the observer's confidence in the diagnosis

  15. Comparison of SPECT and CT in detecting skull base invasion in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zhang Li; Wang Jinchuan; Pu Nuo; Song Wenzhong; Chen Mingxi

    2002-01-01

    Objective: To investigate the detecting ability of single photon emission computed tomography (SPECT) and CT in skull base invasion in nasopharyngeal carcinoma. Methods: Sixty-three patients with nasopharyngeal carcinoma were examined by whole body and skull base SPECT and CT of nasopharynx and skull base before radiotherapy. The results were double-blind compared and evaluated. Results: The overall positive rates of skull base invasion detected by SPECT and CT were 63.5% and 25.4%. In patients with headache, cranial nerve palsy and both, they were 87.9%, 93.3%, 92.3% and 42.4%, 46.7%, 46.2%. In patients with T 1 + T 2 and T 3 + T 4 lesions, they were 37.5%, 90.3% and 0.0%, 51.6%. In patients with N 0 + N 1 and N 2 + N 3 lesions, they were 63.9%, 63.0% and 19.4%, 33.3%. The positive rates of SPECT were higher than those of CT (McNemar Test, P < 0.05). The conformation rate between SPECT and CT was 61.9% and the dissimilitude rate was 38.1%. Binary Logistic regression analysis showed that headache and T stages were risk factors of positive SPECT rate (ORheadache = 3.864, ORTstage= 6.422) while Tstage and Nstage were the risk factors for positive CT rate (ORTstage = 48.932, ORNstage = 2.860). Conclusions: The detection sensitivity of SPECT in skull base invasion in nasopharyngeal carcinoma is superior to that of CT. But its specificity is inferior to that of CT. The detecting results in SPECT are better related to symptoms, signs and stage. Combining headache and cranial nerve palsy with T and N stage, the authors may much improve the results of SPECT and CT in the detection of skull base invasion in nasopharyngeal carcinoma. Further study is warranted

  16. ATP-loading 201Tl myocardial SPECT for the detection of ischemic heart disease

    International Nuclear Information System (INIS)

    Fujinaga, Tsuyoshi; Yamazaki, Sayaka; Hara, Masatada; Umezawa, Chiaki; Okamura, Tetsuo; Murata, Hajime; Maruno, Hirotaka; Onoguchi, Masahisa.

    1993-01-01

    To evaluate the usefulness for the detection of ischemic heart disease, ATP myocrdial SPECT was performed in 35 patients (mean; 59±9.4 years) with angina pectoris or old myocardial infarction. Coronary angiography (CAG) was performed in all patients. The ultra-short half-life of ATP required a continuous infusion for its use. ATP was infused intravenously at a rate of 0.16 mg/kg/min for 5 min, with 201 Tl injection taking place at 3 min. Myocardial SPECT imaging was begun 5 min and 4 hr later after the end of ATP infusion. ATP caused a significant decrease in arterial blood pressure (p 201 Tl myocardial SPECT for the detection of coronary artery disease (CAD) was evaluated using CAG as a golden standard. The sensitivity and specificity for CAD detection were 82% and 90%, respectively. ATP myocardial SPECT is a promising new test for the detection of ischemic heart disease. (author)

  17. Gallium-67 myocardial imaging for the detection of bacterial endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Wiseman, J.; Rouleau, J.; Rigo, P.; Strauss, H.W.; Pitt, B.

    1976-07-01

    Eleven patients with a clinical diagnosis of bacterial endocarditis underwent scintillation scanning of the precordial region 2--7 days after the intravenous administration of 3 mCi of gallium-67 citrate. Seven had positive scans, 3 of which were confirmed by postmortem imaging at autopsy. Serial images revealed the scans to be frequently negative at 48 hours and positive from 3 to 8 days following injection. Uptake was not seen in the region of the myocardium 48 hours or longer after the injection of 15 patients without endocarditis used as controls.

  18. Gallium-67 myocardial imaging for the detection of bacterial endocarditis

    International Nuclear Information System (INIS)

    Wiseman, J.; Rouleau, J.; Rigo, P.; Strauss, H.W.; Pitt, B.

    1976-01-01

    Eleven patients with a clinical diagnosis of bacterial endocarditis underwent scintillation scanning of the precordial region 2--7 days after the intravenous administration of 3 mCi of gallium-67 citrate. Seven had positive scans, 3 of which were confirmed by postmortem imaging at autopsy. Serial images revealed the scans to be frequently negative at 48 hours and positive from 3 to 8 days following injection. Uptake was not seen in the region of the myocardium 48 hours or longer after the injection of 15 patients without endocarditis used as controls

  19. Utility of MDP bone SPECT in the detection of osseous invasion in craniofacial malignancies

    International Nuclear Information System (INIS)

    Saeed, S.; Haq, S.; Sohaib, M.; Khan, A.N.

    2002-01-01

    Aim: The study was designed to observe the role of SPECT imaging for the detection of osseous invasion in craniofacial malignancies. Material and Methods: Radionuclide bone imaging with Tc-99m MDP was done on 20 patients with different craniofacial malignancies. The planar imaging comprised of anterior, lateral and oblique lateral views of the skull. SPECT imaging was done taking 64 views of the skull in a 360 deg. circular path, each of 40 seconds with 128x128 matrix. Visual interpretation of the scans was done and a score of 0, 1, or 2 allocated, representing a lesion as definitely absent, doubtful or definitely present, respectively. SPECT images were compared with planar scans. Results: SPECT was proven superior to planar imaging and radiographs in detection as well as efficient demonstration of the extent of osseous invasion of a craniofacial cancer. The sensitivity was 100% for SPECT, 83.3% for planar and 33.3% for radiographs. Conclusion: SPECT imaging of the skull can serve as an extremely useful complementary investigation in the patients with craniofacial malignancies to assess them for osseous invasion, particularly in tumors likely to invade the skull base

  20. Kinase detection with gallium nitride based high electron mobility transistors.

    Science.gov (United States)

    Makowski, Matthew S; Bryan, Isaac; Sitar, Zlatko; Arellano, Consuelo; Xie, Jinqiao; Collazo, Ramon; Ivanisevic, Albena

    2013-07-01

    A label-free kinase detection system was fabricated by the adsorption of gold nanoparticles functionalized with kinase inhibitor onto AlGaN/GaN high electron mobility transistors (HEMTs). The HEMTs were operated near threshold voltage due to the greatest sensitivity in this operational region. The Au NP/HEMT biosensor system electrically detected 1 pM SRC kinase in ionic solutions. These results are pertinent to drug development applications associated with kinase sensing.

  1. Early detection of infantile endocarditis by gallium-67 scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Hardoff, R; Luder, A S; Lorber, A; Dembo, L

    1989-04-01

    An infant with suspected soft tissue infection of the knee was studied by /sup 67/Ga-scintigraphy. In addition to knee and hip joint increased activity, heart uptake was also demonstrated prior to the development of clinical signs of endocarditis. The early detection and treatment resulted in satisfactory clinical resolution.

  2. Early detection of infantile endocarditis by gallium-67 scintigraphy

    International Nuclear Information System (INIS)

    Hardoff, R.; Luder, A.S.; Lorber, A.; Dembo, L.; Technion-Israel Inst. of Tech., Haifa. Faculty of Medicine)

    1989-01-01

    An infant with suspected soft tissue infection of the knee was studied by 67 Ga-scintigraphy. In addition to knee and hip joint increased activity, heart uptake was also demonstrated prior to the development of clinical signs of endocarditis. The early detection and treatment resulted in satisfactory clinical resolution. (orig.)

  3. Semi-automatic detection and correction of body organ motion, particularly cardiac motion in SPECT studies

    International Nuclear Information System (INIS)

    Quintana, J.C.; Caceres, F.; Vargas, P.

    2002-01-01

    Aim: Detect patient motion during SPECT imaging. Material and Method: SPECT study is carried out on a patient's body organ, such as the heart, and frame of image data are thereby acquired. The image data in these frames are subjected to a series of mappings and computations, from which frame containing a significant quantity of organ motion can be identified. Quantification of motion occurs by shifting some of the mapped data within a predetermined range, and selecting that data shift which minimizes the magnitude of a motion sensitive mathematical function. The sensitive mathematical function is constructed from all set of image frames using the pixel data within a region covering the body organ. Using cine display of planar image data, the operator defines the working region by marking two points, which define two horizontal lines covering the area of the body organ. This is the only operator intervention. The mathematical function integrates pixel data from all set of image frames and therefore does not use derivatives which may cause distortion in noisy data. Moreover, as a global function, this method is superior than that using frame-to-frame cross-correlation function to identify motion between adjacent frames. Using standard image processing software, the method was implemented computationally. Ten SPECT studies with movement (Sestamibi cardiac studies and 99m-ECD brain SPECT studies) were selected plus two others with no movement. The acquisition SPECT protocol for the cardiac study was as follow: Step and shoot mode, non-circular orbit, 64 stops 20s each, 64x64x16 matrix and LEHR colimator. For the brain SPECT, 128 stops over 360 0 were used. Artificial vertical displacements (±1-2 pixels) over several frames were introduced in those studies with no movement to simulate patient motion. Results: The method was successfully tested in all cases and was capable to recognize SPECT studies with no body motion as well as those with body motion (both from the

  4. Detection of mediastinitis after heart transplantation by gallium-67 scintigraphy

    International Nuclear Information System (INIS)

    Quirce, R.; Serano, J.; Arnal, C.; Banzo, I.; Carril, J.M.

    1991-01-01

    We report the findings of a patient with post-cardiac transplant mediastinitis detected by 67 Ga-citrate imaging. Fever and leukocytosis were the first clinical signs suggesting infection. The usual diagnostic modalities, including CT and ultrasound, failed to identify the site of infection. A 67 Ga scan showed intense abnormal uptake behind the sternum. The site of uptake was shown by necropsy to be necrotic tissue involving cardiac sutures, pulmonary arteries, and the aorta due to infection with Haemophilus aphrophilus

  5. Optically detected magnetic resonance of sulfur doped gallium phosphide

    International Nuclear Information System (INIS)

    Brower, K.L.

    1990-01-01

    The authors have recently extended our magnetic resonance capabilities to include optically detected magnetic resonance (ODMR) for purposes of studying defects in III-V compound semiconductors systems. Some of the systems of particular interest with regard to defect studies are samples implanted with particular isotopes. For example, this technique may allow one to observe the hyperfine structure of impurity donors in GaP. Other interesting material systems are the strained layer superlattices and their interfaces. GaP is one of the III-V compound semiconductors of particular interest for ODMR studies. In this paper the authors report the results of preliminary ODMR observations on as-grown sulfur doped GaP

  6. A fully automated contour detection algorithm the preliminary step for scatter and attenuation compensation in SPECT

    International Nuclear Information System (INIS)

    Younes, R.B.; Mas, J.; Bidet, R.

    1988-01-01

    Contour detection is an important step in information extraction from nuclear medicine images. In order to perform accurate quantitative studies in single photon emission computed tomography (SPECT) a new procedure is described which can rapidly derive the best fit contour of an attenuated medium. Some authors evaluate the influence of the detected contour on the reconstructed images with various attenuation correction techniques. Most of the methods are strongly affected by inaccurately detected contours. This approach uses the Compton window to redetermine the convex contour: It seems to be simpler and more practical in clinical SPECT studies. The main advantages of this procedure are the high speed of computation, the accuracy of the contour found and the programme's automation. Results obtained using computer simulated and real phantoms or clinical studies demonstrate the reliability of the present algorithm. (orig.)

  7. Value of dipyridamole stress 201Tl myocardial SPECT in detecting dysfunction of coronary microcirculation

    International Nuclear Information System (INIS)

    Lou Ying; Jiang Jinqi; Xie Wenhui; Yuan Fang; Wang Tong; Yang Yiqing

    2012-01-01

    Objective: To evaluate the value of dipyridamole stress 201 Tl myocardial SPECT in detecting dysfunction of coronary microcirculation. Methods: Forty-eight patients diagnosed with cardiac syndrome X underwent dipyridamole stress 201 Tl myocardial SPECT. Dipyridamole (0.56 mg/kg) was intravenously injected over 4 min followed by 201 Tl (111 MBq) injection at 2 min after dipyridamole administration. Image was acquired at 10 min and 240 min post-injection and co-analyzed by over two experienced doctors in nuclear medicine after three-dimensional reconstruction. The patients with 'reverse redistribution' underwent repeated dipyridamole stress 201 Tl SPECT after medical therapy for 2 weeks. The clinical symptoms and results of the treadmill exercise test pre-and post-therapy were compared. Results: Forty two patients (42/48, 87.50%) showed segmental defects: 'reverse redistribution' on delayed (240 min) 201 Tl images. After medical treatment, 36 cases of the 42 'reverse redistribution' patients had improvement in both clinical symptoms and treadmill exercise test. Post-treatment 201 Tl imaging showed improvement in 45/49 (91.84%) defect segments. Six of the 42 patients had no improvement in clinical symptoms and/or treadmill exercise test. Post-treatment 201 Tl imaging showed no improvement in all the 7 defect segments on the first scan. Conclusion: Dipyridamole stress 201 Tl myocardial SPECT may be valuable in evaluation of impaired coronary microcirculation associated with cardiac syndrome X. (authors)

  8. [Freehand SPECT for navigation and sentinel node detection in breast cancer].

    Science.gov (United States)

    Gillard, C; Franken, P; Darcourt, J; Barranger, E

    2015-02-01

    The sentinel lymph node (SLN) is a standard for the surgical treatment of axillary localized breast cancer N0. It is based on a double isotopic and color detection. With a gamma detecting probe connected to an infrared camera, Déclipse SPECT system (Surgiceye(®)) is able to detect and locate any radioactive source in 3D. Mobile character for use in the operating room is particularly interesting for the intraoperative detection of SLN. We illustrate its usefulness in a clinical case where the preoperative identification of SLN by lymphoscintigraphy was not informative. Copyright © 2014. Published by Elsevier SAS.

  9. Comparison of hybrid {sup 68}Ga-PSMA-PET/CT and {sup 99m}Tc-DPD-SPECT/CT for the detection of bone metastases in prostate cancer patients. Additional value of morphologic information from low dose CT

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, Jan-Carlo; Meissner, Sebastian; Diederichs, Gerd; Hamm, Bernd; Makowski, Marcus R. [Charite, Department of Radiology, Berlin (Germany); Woythal, Nadine; Prasad, Vikas; Brenner, Winfried [Charite, Department of Nuclear Medicine, Berlin (Germany)

    2018-02-15

    This study compared {sup 68}Gallium-prostate-specific-membrane-antigen based Positron-emission-tomography ({sup 68}Ga-PSMA-PET) and {sup 99metastable}technetium-3,3-diphospho-1,2-propanedicarbonacid ({sup 99m}Tc-DPD-SPECT) in performing skeletal staging in prostate cancer (PC) patients and evaluated the additional value of the information from low-dose-computed tomography (CT). In this retrospective study, 54 patients who received {sup 68}Ga-PSMA-PET/CT and {sup 99m}Tc-DPD-SPECT/CT within 80 days were extracted from our database. Osseous lesions were classified as benign, malignant or equivocal. Lesion, region and patient based analysis was performed with and without CT fusion. The reference standard was generated by defining a best valuable comparator (BVC) containing information from all available data. In the patient based analysis, accuracies measured as ''area-under-the-curve'' (AUC) for {sup 68}Ga-PSMA-PET, {sup 99m}Tc-SPECT, {sup 68}Ga-PSMA-PET/CT and {sup 99m}Tc-SPECT/CT were 0.97-0.96, 0.86-0.83, 1.00 and 0.83, respectively (p<0.05) (ranges = optimistic vs. pessimistic view). Region based analysis resulted in the following sensitivities and specificities: 91.8-97.7%, 100-99.5% (PET); 61.2-70.6%, 99.8-98.3% (SPECT); 97.7%, 100% (PET/CT), 69.4% and 98.3% (SPECT/CT) (p<0.05). The amount of correct classifications of equivocal lesions by CT was significantly higher in PET (100%) compared to SPECT (52.4%) (p<0.05). {sup 68}Ga-PSMA-PET outperforms {sup 99m}Tc-DPD-SPECT in detecting bone metastases in PC patients. Additional information from low-dose-CT resulted in a significant reduction in equivocal lesions in both modalities, however {sup 68}Ga-PSMA-PET benefited most. (orig.)

  10. Machine-learning model observer for detection and localization tasks in clinical SPECT-MPI

    Science.gov (United States)

    Parages, Felipe M.; O'Connor, J. Michael; Pretorius, P. Hendrik; Brankov, Jovan G.

    2016-03-01

    In this work we propose a machine-learning MO based on Naive-Bayes classification (NB-MO) for the diagnostic tasks of detection, localization and assessment of perfusion defects in clinical SPECT Myocardial Perfusion Imaging (MPI), with the goal of evaluating several image reconstruction methods used in clinical practice. NB-MO uses image features extracted from polar-maps in order to predict lesion detection, localization and severity scores given by human readers in a series of 3D SPECT-MPI. The population used to tune (i.e. train) the NB-MO consisted of simulated SPECT-MPI cases - divided into normals or with lesions in variable sizes and locations - reconstructed using filtered backprojection (FBP) method. An ensemble of five human specialists (physicians) read a subset of simulated reconstructed images, and assigned a perfusion score for each region of the left-ventricle (LV). Polar-maps generated from the simulated volumes along with their corresponding human scores were used to train five NB-MOs (one per human reader), which are subsequently applied (i.e. tested) on three sets of clinical SPECT-MPI polar maps, in order to predict human detection and localization scores. The clinical "testing" population comprises healthy individuals and patients suffering from coronary artery disease (CAD) in three possible regions, namely: LAD, LcX and RCA. Each clinical case was reconstructed using three reconstruction strategies, namely: FBP with no SC (i.e. scatter compensation), OSEM with Triple Energy Window (TEW) SC method, and OSEM with Effective Source Scatter Estimation (ESSE) SC. Alternative Free-Response (AFROC) analysis of perfusion scores shows that NB-MO predicts a higher human performance for scatter-compensated reconstructions, in agreement with what has been reported in published literature. These results suggest that NB-MO has good potential to generalize well to reconstruction methods not used during training, even for reasonably dissimilar datasets (i

  11. A comparative study of planar, SPECT, x-ray CT and angiographic imaging in the detectability of space occupying lesion (SOL) of liver

    International Nuclear Information System (INIS)

    Manabe, Takao; Oda, Junro; Kamino, Toshio

    1986-01-01

    Planar, SPECT, X-CT, and angiography were compared in 47 patients with suspected SOL in the liver. SPECT had greater sensitivity and specificity in detecting SOLs than planar. Especially the detection of SOL less than 3 cm was improved, and the smallest SOL detected by SPECT was 1.0 cm in diameter. SPECT appears reliable procedure for screening SOLs in the liver. Compared with X-CT, SPECT had nearly equal sensitivity in detecting SOLs more than 3 cm, and X-CT had higher sensitivity in detecting SOLs less than 3 cm. But in some cases, for example isodensity SOL, SPECT could detect the SOL which was missed by X-CT. (author)

  12. MIBI-SPECT in hypofunctioning thyroid nodules for detection of thyroid carcinoma; MIBI-SPECT bei kalten Knoten zur Schilddruesenkarzinomdetektion

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, M.; Schicha, H. [Universitaetsklinikum Koeln (Germany). Klinik und Poliklinik fuer Nuklearmedizin

    2010-12-15

    The clinical usefulness of Tc-99m-MIBI in hypofunctioning thyroid nodules for detection of thyroid carcinoma is presented. Tc-99m-MIBI is a lipophilic cation and a non-specific radiopharmaceutical for tumour imaging. It has become an important imaging technique for the assessment of hypofunctioning thyroid nodules because of its high negative predictive value excluding malignant thyroid tumours. After injection of Tc-99m-MIBI either a single-phase protocol with late planar and SPECT images about 1-2 h post injection or a double-phase protocol with early (about 15-30 min p.i.) and late images (about 2 h p.i.) were reported. Findings include a reduced, an isointense or an increased Tc-99m-MIBI accumulation in the thyroid nodule in comparison to the paranodular thyroid tissue and in comparison to pertechnetate thyroid scintigraphy. A 'Match' between pertechnetate and Tc-99m-MIBI scintigraphy is a concordantly decreased uptake in the thyroid nodule in comparison to the normal thyroid gland. This finding has a negative predictive value of >97% to exclude differentiated thyroid cancer. A definite 'Mismatch' means a cold thyroid nodule on pertechnetate scintigraphy and an increased uptake of Tc-99m-MIBI in comparison to the MIBI-uptake of the paranodular thyroid tissue. The positive predictive value of this finding for malignancy varies between studies and is in the range of <10-65% (Cologne data: 19%) depending on the prevalence of malignant thyroid tumours in the patient population studied. An isointense uptake was not associated with thyroid malignancy according to 'Cologne' data. Further studies are desirable for better characterization of the method. (orig.)

  13. Detecting culprit vessel of coronary artery disease with SPECT 99Tcm-MIBI myocardial imaging

    International Nuclear Information System (INIS)

    Luan Zhaosheng; Zhou Wen; Peng Yong; Su Yuwen; Tian Jianhe; Gai lue; Sun Zhijun

    2002-01-01

    Objective: To assess the value of detecting culprit vessel of coronary artery disease (CAD) with SPECT 99 Tc m -MIBI myocardial imaging. Methods: Forty-six patients with CAD were studied. Every patients had multiple-vessel lesion showed by coronary arteriography and was treated by revascularization as percutaneous transluminal angioplasty (PTCA), coronary artery bypass graft (CABG) or laser holing. Exercise (EX), rest (RE) and intravenous infusion of nitroglycerine (NTG) SPECT 99 Tc m -MIBI myocardial imagings were performed before revascularization. Exercise and rest images revealed the myocardial ischemia. NTG images revealed myocardial viability. Culprit vessels were detected according to the defects showed by above mentioned images. The veracity of detected culprit vessels was tested with the outcome of the reperfusion therapy. Results: In this group, the coronary arteriography revealed 107 lesioned coronary arteries. Myocardial imaging detected 46 culprit vessels including 23 left anterior descending (LAD), 19 left circumflex coronary artery (LCX) and 4 right coronary artery (RCA). All 46 culprit vessels underwent revascularization and had nice outcome. The veracity of 99 Tc m -MIBI myocardial imaging detected culprit vessels was high according to patients' outcome. Conclusion: Exercise, rest and NTG 99 Tc m -MIBI myocardial imaging is a great method for detecting culprit vessels in multivessel coronary disease

  14. SPECT/CT imaging in general orthopedic practice.

    Science.gov (United States)

    Scharf, Stephen

    2009-09-01

    The availability of hybrid devices that combine the latest single-photon emission computed tomography (SPECT) imaging technology with multislice computed tomography (CT) scanning has allowed us to detect subtle, nonspecific abnormalities on bone scans and interpret them as specific focal areas of pathology. Abnormalities in the spine can be separated into those caused by pars fractures, facet joint arthritis, or osteophyte formation on vertebral bodies. Compression fractures can be distinguished from severe degenerative disease, both of which can cause intense activity across the spine on either planar or SPECT imaging. Localizing activity in patients who have had spinal fusion can provide tremendous insight into the causes of therapeutic failures. Infections of the spine now can be diagnosed with gallium SPECT/CT, despite the fact that gallium has long been abandoned because of its failure to detect spine infection on either planar or SPECT imaging. Small focal abnormalities in the feet and ankles can be localized well enough to make specific orthopedic diagnoses on the basis of their location. Moreover, when radiographic imaging provides equivocal or inadequate information, SPECT/CT can provide a road map for further diagnostic studies and has been invaluable in planning surgery. Our ability to localize activity within a bone or at an articular surface has allowed us to distinguish between fractures and joint disease. Increased activity associated with congenital anomalies, such as tarsal coalition and Bertolotti's syndrome have allowed us to understand the pathophysiology of these conditions, to confirm them as the cause of the patient's symptoms, and to provide information that is useful in determining appropriate clinical management. As our experience broadens, SPECT/CT will undoubtedly become an important tool in the evaluation and management of a wider variety of orthopedic patients.

  15. Detection of small size hepatic hemangioma with SPECT

    International Nuclear Information System (INIS)

    Mana, O.; Zatta, G.; Boccolari, S.; Gallazzi, M.; Tarolo, G.L.; Pisani, A.

    1985-01-01

    A case of a patient with hepatic hemangioma was studied by non-invasive methods. Ultrasonography (US) and computed tomography (CT) studies were able to detect some lesions, but not ascertain the diagnosis. Planar scintigraphy both with 99m Tc-sulfur colloid and with in vivo labelled RBC's did not show the lesions, while single-photon emission tomography (blood pool and sulfur colloid) pointed out their presence and allowed to achieve a correct diagnosis for the biggest lesion (2.5 cm in diameter)

  16. Computer-assisted detection of epileptiform focuses on SPECT images

    Science.gov (United States)

    Grzegorczyk, Dawid; Dunin-Wąsowicz, Dorota; Mulawka, Jan J.

    2010-09-01

    Epilepsy is a common nervous system disease often related to consciousness disturbances and muscular spasm which affects about 1% of the human population. Despite major technological advances done in medicine in the last years there was no sufficient progress towards overcoming it. Application of advanced statistical methods and computer image analysis offers the hope for accurate detection and later removal of an epileptiform focuses which are the cause of some types of epilepsy. The aim of this work was to create a computer system that would help to find and diagnose disorders of blood circulation in the brain This may be helpful for the diagnosis of the epileptic seizures onset in the brain.

  17. Gallium-67 detection of intramammary injection sites secondary to intravenous drug abuse

    International Nuclear Information System (INIS)

    Swayne, L.C.

    1989-01-01

    A case of gallium localization within the breast occurred secondary to intravenous drug abuse. In the appropriate clinical setting, prior self-administered injections should be considered as a cause of Ga-67 accumulation at unusual sites

  18. Heterotopic ossification (myositis ossificans) in acquired immune deficiency syndrome. Detection by gallium scintigraphy

    International Nuclear Information System (INIS)

    Drane, W.E.; Tipler, B.M.

    1987-01-01

    A case of heterotopic ossification (myositis ossificans) secondary to the central nervous system complications of acquired immune deficiency syndrome (AIDS) is reported. Because of the overwhelming suspicion of infection in this patient, this diagnosis was not considered until a gallium scan revealed the typical findings of heterotopic ossification. Because of the increasing utilization of gallium imaging in the AIDS population, every imaging specialist should be aware of this potential disorder

  19. Myocardial perfusion SPECT in diabetic patients for detection of coronary artery disease

    International Nuclear Information System (INIS)

    Saeed, M.A.; Fatima, S.; Fatmi, S.; Kureshi, S.

    2003-01-01

    The aim of this study was to evaluate the efficacy of myocardial SPECT perfusion scan in the diagnosis of coronary artery disease in diabetic patients. A total number of thirty diabetic patients (21 males, 9 females) were included in the study. All the patients had strong risk-factors for coronary artery disease (strong family history, chronic smokers, hyperlipidemia, history of chest pain). All patients underwent coronary angiography and stress/rest myocardial perfusion SPECT scans with Tc-99m MIBI (two days protocol). Twenty two patients had significant coronary artery stenosis and 8 had normal coronary arteries. Myocardial perfusion scintigraphy (MPS) was positive in 19 subjects out of the 22 patients with significant stenosis (Sensitivity 86.4%) and negative (false negative) in only three. Out of 8 patients with normal angiography 7 had normal MPS (Specificity 87.5%) whereas only one patient revealed abnormality in the myocardial perfusion study. When compared with coronary angiography the positive predictive value and negative predictive value for Tc-99m MIBI myocardial perfusion scan was 86.4% and 87.5% respectively. In conclusion, Tc-99m MIBI myocardial perfusion scintigraphy is a useful screening modality for the detection of coronary artery disease in diabetic patients. (author)

  20. Comparison of multi-slice CT (MSCT) and TI-201 myocardial SPECT in detection of coronary artery disease: relation to coronary arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S.; Kim, Y. K.; Shim, S. S. [College of Medicine, Univ. of Ewha Womens, Seoul (Korea, Republic of)

    2003-07-01

    To evaluate the diagnostic potentials of MSCT and TI-201 SPECT in the assessment of coronary artery disease. Twenty-four patients (15 men, 9 women, 42-79 years) with clinically suspected coronary artery disease were studied by TI-201 myocardial SPECT and MSCT. MSCT data were obtained with 12 x 0.75 mm, 420ms rotation, multi-slice CT scanner (SOMATOM Sensation, Siemens) using non-ionic contrast, 80ml, 4ml/sec. Multiplanar reconstruction techniques were used for evaluation of coronary arteries. TI-201 myocardial SPECT were performed at stress with adenosine and at rest. Data from MSCT and TI-201 SPECT were compared territory by territory (divided into two segments; LAD and RCA/LCx) and related to coronary arteriography, in which more than 60% stenoses are regarded as significant. MSCT and TI-201 SPECT showed agreement in 37 out of 48 segments (77.1%). Out of 11 disagreed segments (22.9), TI-201 SPECT was superior in 6 segments and MSCT was superior in 5 segments. Sensitivities and specificities of MSCT and TI-201 SPECT by coronary arteriography are 81.8%, 69.2% and 86.3%, 76.9%, respectively. Agreed 4 segments between MSCT and TI-201 SPECT exhibited results that differ from the results of coronary arteriography. Myocardial bridge in two cases were detected as significant stenoses by MSCT but showed normal perfusion in TI-201 SPECT. Agreement between MSCT and TI-201 SPECT in the assessment of coronary artery disease was good but TI-201 SPECT has higher sensitivity and specificity for the detection of jeopardized myocardium than MSCT. MSCT and TI-201 SPECT provide complementary information in the assessment of coronary artery disease and could help reduce probable mistake in the interpretation of hemo dynamically insignificant lesion in coronary arteriography.

  1. Validity of in vivo [123I]beta-CIT SPECT in detecting MDMA-induced neurotoxicity in rats

    NARCIS (Netherlands)

    de Win, Maartje M. L.; de Jeu, Rogier A. M.; de Bruin, Kora; Habraken, Jan B. A.; Reneman, Liesbeth; Booij, Jan; den Heeten, Gerard J.

    2004-01-01

    This study investigated the ability of a high-resolution pinhole single-photon emission computed tomography (SPECT) system, with [(123)I]beta-CIT as a radiotracer, to detect 3,4-methelenedioxymethamphetamine (MDMA, 'Ecstasy')-induced loss of serotonin transporters (SERTs) in the living rat brain. In

  2. Isthmocervical labelling and SPECT/CT for optimized sentinel detection in endometrial cancer: technique, experience and results.

    Science.gov (United States)

    Mücke, J; Klapdor, R; Schneider, M; Länger, F; Gratz, K F; Hillemanns, P; Hertel, H

    2014-08-01

    We evaluated the clinical feasibility of a new injection technique for sentinel detection in endometrial carcinoma (EC), transcervical subepithelial injection into the isthmocervical region of the myometrium. We compared detection of sentinel lymph nodes (SLN) by single photon emission computed tomography with CT (SPECT/CT) with planar lymphoscintigraphy. This is a unicentric prospective study. In all patients, transcervical injection of 10 MBq Technetium-99m-nanocolloid was performed into the isthmocervical myometrium without anaesthesia. After 40 (30-60) min, lymphoscintigraphy and SPECT/CT were performed. Patent blue was administered before surgery. The number and localisation of SLN detected in SPECT/CT and lymphoscintigraphy were recorded and compared to the SLN and non-SLN dissected intra-operatively. Between August 2008 and March 2012, 31 patients with EC were enrolled. The new transcervical injection of labelling substances led to high intra-operative (90.3%) detection rates, pelvic bilateral (57%), para-aortic (25%). SPECT/CT significantly identified more SLN than lymphoscintigraphy (mean 2.2 (1-8) to 1.3 (1-7)) in more patients (29/31 (93.5%) to 21/31 (68%), pnegative predictive value (NPV) 100%, and false negative results 0%. Transcervical SLN marking in combination with SPECT/CT is easily applicable and leads to high physiologic detection rates in pelvic and para-aortic lymphatic drainage areas. Non-affected SLN truly predicted a non-affected LN basin. Combining both methods SLN dissection may be a safe and feasible staging technique for clinical routine in EC. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Early and delayed pinhole MIBI SPECT in detecting hyperfunctioning parathyroid glands: a comparison with peroperative γ probe.

    Science.gov (United States)

    Gültekin, Salih Sinan; Kir, Metin; Tuğ, Tuğbay; Demirer, Seher; Genç, Yasemin

    2011-10-01

    This study was conducted to evaluate the early and delayed pinhole MIBI single photon emission computed tomography (pSPECT) images in detecting hyperfunctioning parathyroid glands, to make a comparison with peroperative γ probe (GP) findings. Planar, early, and delayed pSPECT scans and skin in-vivo and ex-vivo GP counts were obtained in 22 patients with hyperparathyroidism. All data were analyzed statistically on the basis of localization of the lesions, using the histopathological findings as the gold standard. Histopathological examinations revealed 18 of 44 adenomas, 18 of 44 hyperplasic glands, two of 44 lymph nodules, five of 44 thyroid nodules, and one of 44 normal parathyroid glands. Sensitivity and specificity were found to be 36 and 100% for planar, 69 and 75% for early pSPECT, 86 and 88% for delayed pSPECT scans, and similarly, 78 and 75% on skin, 92 and 75% in-vivo and 83 and 100% ex-vivo GP counts, respectively. For distinction ability of GP counts between three groups of lesions, there was a statistically significant difference among the three groups for ex-vivo GP counts but not between groups of adenomas and hyperplasic lesions for in-vivo GP counts. Early and delayed pSPECT scans play a complementary role on the planar scans. Delayed pSPECT scans and in-vivo GP counts are equally valuable to localize both single and multiple hyperfunctioning parathyroid glands. Ex-vivo GP counts seem to be better for making a distinction among types of lesions.

  4. Comparison of benzodiazepine receptor SPECT and 18F-FDG PET using a coincidence detection camera in patients with temporal lobe epilepsy: preliminary results

    International Nuclear Information System (INIS)

    Wissmeyer, M.; Geiger, L.; Luescher, D.; Krause, T.; Loevblad, K.; Donati, F.; Wielepp, J.P.

    2002-01-01

    Full text: The aim of this preliminary study was to compare the results of benzodiazepine receptor (BDR) SPECT using 123 I-Iomazenil with those of 18 F-FDG (FDG) PET obtained on a double-headed gamma camera with a coincidence detection system in patients with temporal lobe epilepsy (TLE). We evaluated 6 patients (4 female, 2 male; age range 26-54 years, average 43.5 years) with therapy-refractory TLE due to mesiotemporal sclerosis or other focal brain anomalies. To delineate the epileptogenic zone, clinical evaluation, ictal and interictal surface EEG using the international 10-20 system, brain MRI, interictal CBF SPECT using 99m Tc-ECD, BDR SPECT and FDG coincidence PET were performed. The CBF SPECT, BDR SPECT and coincidence PET scans were viewed independently by 2 observers considering the regional cerebral blood flow, BDR density and FDG uptake asymmetry in the temporal lobe visually as none (0), low (1), moderate (2) and high (3). Ictal and interictal EEG recordings located the epileptogenic focus in all patients in the temporal region. Both the BDR SPECT and the FDG coincidence PET located the epileptogenic focus correctly in circumscribed areas of the temporal lobe in all patients, whereas brain MRI revealed focal anomalies only in 5 of 6 cases . The lateralization to the right (n=4) and left hemisphere (n=2) by interictal CBF SPECT, BDR SPECT and FDG coincidence PET corresponded to the EEG findings in all patients. The visual consideration of the asymmetry revealed a slightly but not statistically significant higher value for the FDG coincidence PET (observer 1: mean 2.333, SD 0.516; observer 2: mean 2.000, SD 0.632) than for the BDR SPECT (observer 1: mean 1.667, SD 1.033; observer 2: mean 1.833, SD 0.753). Visual consideration of the interictal CBF SPECT revealed mean values of 2.000 for both observers. The inter-observer variability was higher in the BDR SPECT than in the FDG coincidence PET and the interictal CBF SPECT, but the difference was not

  5. Sentinel lymph node mapping using SPECT/CT and gamma probe in endometrial cancer: an analysis of parameters affecting detection rate

    Energy Technology Data Exchange (ETDEWEB)

    Sahbai, Samine; La Fougere, Christian; Dittmann, Helmut [University Hospital Tuebingen, Nuclear Medicine and Clinical Molecular Imaging, Tuebingen (Germany); Taran, Florin-Andrei; Wallwiener, Diethelm; Brucker, Sara [University Hospital Tuebingen, Gynecology and Obstetrics, Tuebingen (Germany); Staebler, Annette [University Hospital Tuebingen, Pathology, Tuebingen (Germany)

    2017-08-15

    SPECT/CT after pericervical injection of technetium-99 m-nanocolloid was shown to be suitable for sentinel lymph node (SLN) mapping in endometrial cancer (EC). The aim of this study was to analyze factors affecting successful SLN detection by means of SPECT/CT such as imaging findings, patient characteristics and tumor biology in a large cohort of patients. One hundred and forty-five consecutive patients suffering from EC who received pre-surgical SLN mapping at our institution between 2011 and 2016 were included in this analysis. SPECT/CT data of abdomen and pelvis (mean 4:20 ± 1:20 h p.i.) were acquired after pericervical injection of technetium-99 m-nanocolloid (mean 230 ± 45 MBq) in all patients. Surgical staging was performed on the day after. Acquisition parameters, patient characteristics, SPECT/CT findings as well as histopathological results were collected. A total of 282 SLNs were identified by means of SPECT/CT. Overall, preoperative and intraoperative SLN detection rates were 86%, 76% and 74% respectively. The most important factor associated with failure to detect SLNs was the presence of high bone marrow on SPECT/CT (p = 0.005). Peritoneal/abdominal radioactivity was also associated with missed SLN detection in SPECT/CT (p = 0.02). However, the presence of liver/spleen uptake on its own was not predictive for detection failure. Low numbers of detected SLNs in SPECT/CT were slightly related with older age and lower injected activity. No significant influence was found for the parameters of tumor histology and stage, lymph node involvement and the time gap between injection and imaging. Venous drainage as indicated by bone marrow uptake is the most important factor associated with scintigraphic SLN detection failure. Moreover, high peritoneal and abdominal activity was also associated with detection failure. Thus, meticulous application of the radiotracer is crucial in EC. (orig.)

  6. A very accurate method for sentinel lymph node investigation: Gamma detecting probe associated with SPECT examination for depth

    International Nuclear Information System (INIS)

    Ascoli, G.; Cinti, P.; Nonni, M.; Rossi, B.

    2002-01-01

    Aim: aim of this study is to magnify the lymphoscintigraphy examination by gamma probe with SPECT acquisition for very accurate detection of depth of axilla node in patients affected by melanoma. Methods: according to physiological peculiarities the lymphatic system plays a very important role and represents the most important barrier to neoplastic cells spreading. The 'sentinel node' is the first lymph node draining the affected area. The tendency for surgery is a 'preventive' axillary dissection, even in presence of a clinically negative examination. In fact a high percentage of clinically negative lymph node shows a positive histology (presence of metastatic cells). The nuclear medicine method for researching 'sentinel node' is represented by a regional lymphoscintigraphy with normal gamma camera with a large field of view followed by examination with gamma detecting probe and, in following day, controlled in operating room to confirm the presence of the node early identified. We have completed this protocol with SPECT examination of affected axilla by use of injected laboratory capillary around axilla to perform an exact investigation of node depth. Discussion: Our experience in 150 cases in 18 months shows 100% of axilla 'sentinel node' detection, 25 cases with positive histologic examination and subsequently axillary dissection. Conclusions: In conclusion the scintigraphic examination with lymphoscintigraphy represents a good tool for management of patient with melanoma and the use of ''targeting' with collimated SPECT represent a very aid for the surgeon in reduction time for detection and dissection of lymph node, with high reduction of anesthesia duration

  7. Detection of coronary artery disease with exercise 99Tcm-MIBI SPECT in patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Yang Minfu; Guo Xinhua; He Zuoxiang; Tou Kefei; Yang Yuejin

    2007-01-01

    Objective: To investigate the ability of exercise myocardial perfusion imaging (MPI) for detecting coronary artery disease (CAD) in patients with atrial fibrillation (AF). Methods: Fifty-eight consecutive patients with AF during symptom-limited exercise 99 Tc m -methoxyisobutylisonitrile (MIBI) SPECT imaging were retrospectively analyzed. All patients underwent coronary angiography within an interval of 90 d. Results: The overall diagnostic sensitivity, specificity and accuracy of exercise 99 Tc m -MIBI SPECT were 60% (9/15), 88% (38/43) and 81% (47/58), respectively. Among patients without valvular disease, the diagnostic sensitivity and specificity were 60% (9/15) and 96% (22/23). The diagnostic accuracy was 80% (16/20) in patients with valvular heart disease. Conclusion: In patients with AF during exercise test, exercise MPI has a moderate sensitivity and an excellent specificity in detection of CAD to those without valvular disease, and has a high diagnostic accuracy in patients with valvular heart disease. (authors)

  8. Early detection of femoral head avascular necrosis by bone SPECT compared to MRI in renal allograft recipients

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Do Young; Yang, Seoung Oh; Lee, Hee Kyung; Han, Duck Jong; Shin, Myung Jin [Asan Mecical Center, Seoul (Korea, Republic of)

    1997-07-01

    The prevalence of avascular necrosis (AVN) of femoral head in patients who receive immunosuppresive agents after renal transplantation is reported to be 4-29%. Among patients who develop AVN after renal transplantation, 80% become symptomatic within 2 years after transplantation. As the number of renal transplantation has been increased recently, early detection of femoral head AVN is very important because early surgical core decompression of femoral head can prevent collapse of the head. MRI is known to be very sensitive to diagnose femoral head AVN. However in three cases we report here, bone SPECT showed early changes of femoral head AVN, whereas MRI showed no specific abnormality. Case 1. A 53-year-old female received an allograft kidney transplantation in 1994. Preoperative bone scan was normal. She complained of both hip pain on Mar. 18 1997. Bone SPECT showed cold defect in both femoral heads but MRI showed no abnormality. After 3 months, bone SPECT and MRI showed AVN of both femoral heads. She underwent bilateral total hip replacement arthroplasty. AVN of femoral heads was confirmed by microscopic examination. Case 2. A 38-year-old female received an allograft kidney transplantation in Feb. 27 1997. Preoperative bone scan was normal. She ran a fever and creatinine was elevated from 1.2 to 2.8 mg/dL. She took high dose methylprednisolone therapy for acute reanl rejection. After two days, she complained pain in both hip joints and knee joints. Bone SPECT showed cold defects in both femoral heads but MRI showed no abnormality. A follow-up bone SPECT and MRI 20 days later revealed AVN of both femoral heads. Case 3. A 50-year-old male received an allograft kidney transplantation on Jul. 12 1995. Preoperative bone scan was normal. He complained of right hip pain on Jul, 26 1995. His bone SPECT showed cold defects in both femoral heads while MRI showed only minimal hip joint effusion. He also complained of left hip pain on Oct. 2 1995. He was admitted on Mar 17

  9. Early detection of femoral head avascular necrosis by bone SPECT compared to MRI in renal allograft recipients

    International Nuclear Information System (INIS)

    Kang, Do Young; Yang, Seoung Oh; Lee, Hee Kyung; Han, Duck Jong; Shin, Myung Jin

    1997-01-01

    The prevalence of avascular necrosis (AVN) of femoral head in patients who receive immunosuppresive agents after renal transplantation is reported to be 4-29%. Among patients who develop AVN after renal transplantation, 80% become symptomatic within 2 years after transplantation. As the number of renal transplantation has been increased recently, early detection of femoral head AVN is very important because early surgical core decompression of femoral head can prevent collapse of the head. MRI is known to be very sensitive to diagnose femoral head AVN. However in three cases we report here, bone SPECT showed early changes of femoral head AVN, whereas MRI showed no specific abnormality. Case 1. A 53-year-old female received an allograft kidney transplantation in 1994. Preoperative bone scan was normal. She complained of both hip pain on Mar. 18 1997. Bone SPECT showed cold defect in both femoral heads but MRI showed no abnormality. After 3 months, bone SPECT and MRI showed AVN of both femoral heads. She underwent bilateral total hip replacement arthroplasty. AVN of femoral heads was confirmed by microscopic examination. Case 2. A 38-year-old female received an allograft kidney transplantation in Feb. 27 1997. Preoperative bone scan was normal. She ran a fever and creatinine was elevated from 1.2 to 2.8 mg/dL. She took high dose methylprednisolone therapy for acute reanl rejection. After two days, she complained pain in both hip joints and knee joints. Bone SPECT showed cold defects in both femoral heads but MRI showed no abnormality. A follow-up bone SPECT and MRI 20 days later revealed AVN of both femoral heads. Case 3. A 50-year-old male received an allograft kidney transplantation on Jul. 12 1995. Preoperative bone scan was normal. He complained of right hip pain on Jul, 26 1995. His bone SPECT showed cold defects in both femoral heads while MRI showed only minimal hip joint effusion. He also complained of left hip pain on Oct. 2 1995. He was admitted on Mar 17

  10. Development of a high-resolution detection module for the INSERT SPECT/MRI system

    Energy Technology Data Exchange (ETDEWEB)

    Busca, Paolo; Fiorini, Carlo; Butt, Arslan D; Occhipinti, Michele; Quaglia, Riccardo; Trigilio, Paolo [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Via Golgi 40, 20133 Milano (Italy); Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Via Celoria 16, 20133 Milano (Italy); Nemeth, Gabor; Major, Peter; Bukki, Tamas; Nagy, Kalman [Mediso Medical Imaging Systems, Alsotorokvesz 14, H-1022 Budapest (Hungary); Piemonte, Claudio; Ferri, Alessandro; Gola, Alberto [Fondazione Bruno Kessler (FBK), Via Sommarive, 18, 38123 Trento (Italy); Rieger, Jan [MRI.TOOLS GmbH, Robert-Roessle-Str. 10, 13125 Berlin (Germany); Niendorf, Thoralf [MRI.TOOLS GmbH, Robert-Roessle-Str. 10, 13125 Berlin (Germany); Berlin Ultrahigh Field Facility (B.UniversityF.F.), Max-Delbrueck-Center for Molecular Medicine, Berlin (Germany)

    2014-07-29

    A new multi-modality imaging tool is under development in the framework of the INSERT (Integrated SPECT/MRI for Enhanced Stratification in Radio-chemo Therapy) project, supported by the European Community. The final goal is to develop a custom SPECT apparatus that can be used as an insert for commercially available MRI systems. INSERT is expected to offer more effective and earlier diagnosis with potentially better outcome in survival for the treatment of brain tumors, primarily glioma. Two SPECT prototypes are being developed, one dedicated to preclinical imaging (7 and 9.4 T), the second one dedicated to clinical imaging (3 T).

  11. Development of a high-resolution detection module for the INSERT SPECT/MRI system

    International Nuclear Information System (INIS)

    Busca, Paolo; Fiorini, Carlo; Butt, Arslan D; Occhipinti, Michele; Quaglia, Riccardo; Trigilio, Paolo; Nemeth, Gabor; Major, Peter; Bukki, Tamas; Nagy, Kalman; Piemonte, Claudio; Ferri, Alessandro; Gola, Alberto; Rieger, Jan; Niendorf, Thoralf

    2014-01-01

    A new multi-modality imaging tool is under development in the framework of the INSERT (Integrated SPECT/MRI for Enhanced Stratification in Radio-chemo Therapy) project, supported by the European Community. The final goal is to develop a custom SPECT apparatus that can be used as an insert for commercially available MRI systems. INSERT is expected to offer more effective and earlier diagnosis with potentially better outcome in survival for the treatment of brain tumors, primarily glioma. Two SPECT prototypes are being developed, one dedicated to preclinical imaging (7 and 9.4 T), the second one dedicated to clinical imaging (3 T).

  12. Detection of spin-states in Mn-doped gallium arsenide films

    International Nuclear Information System (INIS)

    Hofer, Werner A; Palotas, Krisztian; Teobaldi, Gilberto; Sadowski, Janusz; Mikkelsen, Anders; Lundgren, Edvin

    2007-01-01

    We show that isolated magnetic dipoles centred at the position of manganese impurities in a gallium arsenide lattice lead to spin polarized states in the bandgap of the III-V semiconductor. Spectroscopy simulations with a tungsten tip agree well with experimental data; in this case, no difference can be observed for the two magnetic groundstates. But if the signal is read with a magnetic iron tip, it changes by a factor of up to 20, depending on the magnetic orientation of the Mn atom

  13. Comparison of Tc-99m HM-PAO SPECT brain scan and x-ray CT in the detection of brain metastases

    International Nuclear Information System (INIS)

    Abdel-Dayem, H.M.; Sadek, S.; Sahwell, A.; Kubasek, H.; El-Sayed, M.; Ziada, G.; Mobarak, L.; Al-Huda, F.; Omar, Y.T.

    1986-01-01

    Tc-99m HM-PAO imaging was compared with x-ray CT in 14 patients with known or suspected brain metastases. Both studies were done within 3 days of each other. Static and single photon emission CT (SPECT) images were acquired after intravenous injection of 13 mCi of Tc-99m HM-PAO. All 14 patients underwent static and SPECT Tc-99m HM-PAO imaging and x-ray CT. Studies were positive in 7, 12, and 10 patients, respectively, by static, SPECT, and x-ray CT imaging, and negative in 7, 2, and 2. The number of lesions identified was 0 (static imaging), 32 (SPECT), and 26(x-ray CT). There were no ''suspicious'' studies by any modality. This study indicates that Tc-99m HM-PAO SPECT cerebral blood flow imaging is more sensitive than x-ray CT for detecting brain metastases, that biplane imaging is not sensitive and SPECT is essential, and that for Tc-99m HM-PAO SPECT brain imaging to regain its importance with respect to x-ray CT, acquisition time must be 10 minutes or less and determination of percentage brain uptake of the injected dose, and of regional distribution, is necessary

  14. Quantitation of myocardial blood flow and myocardial flow reserve with {sup 99m}Tc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, Bailing [University of Missouri-Columbia, Nuclear Science and Engineering Institute, Columbia, MO (United States); Chen, Fu-Chung; Chen, Chien-Cheng [Show Chwan Memorial Hospital, Section of Cardiology, Department of Internal Medicine, Changhua (China); Wu, Tao-Cheng [Taipei Veterans General Hospital, Section of Cardiology, Department of Internal Medicine, Taipei (China); Huang, Wen-Sheng [Changhua Christian Hospital, Department of Medical Research and Department of Nuclear Medicine, Changhua (China); Hou, Po-Nien [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Hung, Guang-Uei [Chang Bing Show Chwan Memorial Hospital, Department of Nuclear Medicine, Lukong Town, Changhua Shien (China); Central Taiwan University of Science and Technology, Department of Medical Imaging and Radiological Science, Taichung (China); China Medical University, Department of Biomedical Imaging and Radiological Science, Taichung (China)

    2014-12-15

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or <50 % stenosis). DySPECT and GSPECT scans were performed on a widely used dual-head SPECT/CT scanner. The DySPECT imaging protocol utilized 12-min multiple back-and-forth gantry rotations during injections of {sup 99m}Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a

  15. The Role of Routine Whole Volume SPECT Reconstruction in Comparison to Cine Raw Data in the Detection of Extracardiac Uptake on Myocardial Perfusion Scans

    International Nuclear Information System (INIS)

    Maharaj, M.; Korowlay, N.A.

    2011-01-01

    The objective of this study was to determine the role of routine whole volume reconstructed single-photon emission tomography (rSPECT) compared to cine raw data to detect extracardiac uptake of Sestamibi (MIBI). In a retrospective study, the myocardial perfusion studies of 426 patients were inspected separately for extracardiac uptake on cine raw data and rSPECT. The acquisition parameters for all the images were done according to departmental protocol. The whole volume SPECT data was selected and processed by HOSEM iterative reconstruction using the HERMES computer software system. The images were assessed by two observers, a student in training and a senior consultant nuclear medicine physician. The overall mean age and standard deviation of the 426 patients at the time of the study was 60 ± 12 years. Statistical analysis was performed using the Kappa and McNemars tests. The clinical significance of the extracardiac uptake was evaluated using hospital folders and /or laboratory results after viewing images. rSPECT detected 25 patients (5.9%) and cine raw data identified 18 patients (4.2%) with extracardiac uptake. All the areas of extracardiac uptake noted on cine raw data were seen on the rSPECT images. Only 21 of the 25 patients had complete 5-year clinical follow-up. The value of the clinical significance of the extracardiac uptake was limited due to the study being retrospective. The proportion of positives identified by rSPECT was significantly larger than those identified by cine raw data (P = 0.0082). Although our study demonstrates that rSPECT is more sensitive than cine raw data in detecting extracardiac uptake, it also shows that there is no benefit in routine whole volume rSPECT in daily clinical practice

  16. Gallium scintigraphy in AIDS

    International Nuclear Information System (INIS)

    Van der Wall, Hans; Provan, I.; Murray, C.; Dwyer, M.; Jones, P.D.

    1990-01-01

    Gallium-67 scanning, indicated either for the elucidation of symptoms or for the assessment of appropriate therapy, was performed in 56 AIDS patients who underwent a total of 77 scans from 1986 to 1988. The age range of the patients was 13-66 years with an average age of 39 years. The majority of patients (95%) were male homosexuals. Gallium scanning has been applied to a wide spectrum of malignancies and to the detection of occult infections. Several mechanisms of uptake have been postulated for the localization of gallium. In general, gallium-67 acts as an analogue of the ferric ion, binding to transferrin soon after intravenous injection. It is believed that it is bound to transferrin receptors on the surface of tumour cells with subsequent intracellular transport. In infection, the association is probably with lactoferrin elaborated by polymorphonuclear cells and siderophores elaborated by bacteria. Gallium-67 is normally distributed to bone and bone marrow, liver, spleen, breast and bowel. In particular, the concentration in the ascending and transverse colon necessitates adequate bowel preparation. Lacrimal, nasopharyngeal and genital activity may also be seen. 11 refs., 2 tabs., 6 figs

  17. Differential diagnosis of MRI detected intra cranial space occupying lesions (ICSOLS)-role of 99MTC tetrofosmin cerebral spect

    International Nuclear Information System (INIS)

    Padmal, S.; Sundaram, P.S.; Kumar, S.

    2004-01-01

    Discriminating the correct etiology of Intra Cranial Space Occupying Lesions (ICSOLs) detected by MRI is of paramount importance in deciding the right therapeutic approach. Functional imaging like 99m Tc Tetrofosmin cerebral SPECT (C SPECT) can be used to differentiate malignant from other benign cerebral pathologies. Objective: Our aim was to assess the efficacy of C SPECT in differentiating various etiologies (i.e. Infective / Inflammatory, Neoplastic and Post Radiotherapy changes) of MRI detected ICSOLs. We also aimed to assess the incremental value of quantitative uptake ratios in identifying the exact nature of ICSOLs. Method: 26 Patients (M:F=20:6), age range 28-76 yrs, mean 42±7 yrs were evaluated by 99mTc Tetrofosmin cerebral SPECT. 14/26 patients were HIV positive cases while remaining 12 were treated patients of intracerebral malignancies. All these patients had one or more discrete MRI detected ICSOLs. 6/4 patients with HIV and 4/12 patients in the non HIV group showed more than 1 discrete ICSOLs. 20 mci of 99mTc Tetrofosmin was injected IV .15 min (early) and 2 hrs (delayed) post injection C SPECT images were acquired on a dual head variable angle Gamma camera. After reconstruction, transverse, coronal and sagittal images were co- registered with DICOM online available MRI images using aco- registration software. Focal Tetrofosmin uptake in MRI detected ICSOL was interpreted as abnormal. Tetrofosmin uptake index (Ix) was calculated in early and delayed images as ratio of counts in lesion to that of contra lateral region. A value of more than 1.3 was considered to be abnormal. Persistent Ix of more than 1.3 in initial and delayed images were considered to be malignant while Ix of more or less than 1.3 in initial but less than 1.3 in delayed images was considered to be benign in both groups. Results: In HIV group (14 pts), 4 patients showed an Ix of less than 1.3 in both early and delayed images and 7 patients showed an Ix of more than 1.3 in early but

  18. Physics process level discrimination of detections for GATE: assessment of contamination in SPECT and spurious activity in PET.

    Science.gov (United States)

    De Beenhouwer, Jan; Staelens, Steven; Vandenberghe, Stefaan; Verhaeghe, Jeroen; Van Holen, Roel; Rault, Erwann; Lemahieu, Ignace

    2009-04-01

    The GEANT4 application for tomographic emission (GATE) is one of the most detailed Monte Carlo simulation tools for SPECT and PET. It allows for realistic phantoms, complex decay schemes, and a large variety of detector geometries. However, only a fraction of the information in each particle history is available for postprocessing. In order to extend the analysis capabilities of GATE, a flexible framework was developed. This framework allows all detected events to be subdivided according to their type: In PET, true coincidences from others, and in SPECT, geometrically collimated photons from others. The framework of the authors can be applied to any isotope, phantom, and detector geometry available in GATE. It is designed to enhance the usability of GATE for the study of contamination and for the investigation of the properties of current and future prototype detectors. The authors apply the framework to a case study of Bexxar, first assuming labeling with 124I, then with 131I. It is shown that with 124I PET, results with an optimized window improve upon those with the standard window but achieve less than half of the ideal improvement. Nevertheless, 124I PET shows improved resolution compared to 131I SPECT with triple-energy-window scatter correction.

  19. Optimisation of conditions for detecting variations in focal activity in SPECT using the rotating gamma camera

    International Nuclear Information System (INIS)

    Wust, P.; Golde, G.; Schneider, R.; Fiegler, W.; Hedde, J.P.

    1986-01-01

    The signal to noise ratio (quotient of contrast and mean noise) is a quality parameter for identifying activity gaps during single photon emission computed tomography (SPECT). Contrast and mean noise level are site-dependent on the reconstruction plane which is influenced in a complex manner by absorption conditions (strong or weak absorption), modes of rotation (full angle or partial angle imaging), interdependencies of opposing partial projections (arithmetic or geometric mean), magnitude of defect (relative to the resolution of the imaging system), geometry of the object to be measured, and scatter. In the present study the authors performed analysis and graphical representation of the SPECT imaging properties on the basis of model calculations illustrated by phantom measurements. The optimal conditions of examination or evaluation and the diagnostic criteria in SPECT of the heart, liver, brain and pelvis are discussed by comparative calculation of signal to noise ratios in defect identification. (orig.)

  20. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B

    2004-01-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP

  1. Detection of myocardial ischemia with myocardial perfusion SPECT in patients with diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Seo, J. H.; Jeong, S. Y.; Bae, J. H.; Anh, B. C.; Lee, J.; Lee, K. B [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2004-07-01

    Diabetes mellitus(DM) is a critical disease associated with higher rates of cardiovascular morbidity and mortality. Atherosclerosis accounts for 65-80% of all deaths in diabetic patients and patients with DM are known to show high prevalence of coronary artery diseases(CAD). We evaluated the incidence of scintigraphic evidence of CAD in diabetic patients and results were compared with cardiovascular symptoms and clinical factors. 169 patients with DM(mean age 629years, 68 males) were referred for evaluation of CAD between Jan 2002 and Dec 2003. 101(60%) patients were with chest pain and 68(40%) were asymptomatic. Patients underwent exercise(n=6) or adenosine stress(n=163) SPECT myocardial perfusion imaging(MPI). Exclusion criteria included history of documented myocardial infarction, prior revascularization, clinically significant valvular heart disease, left-bundle branch block on rest ECG. We evaluated symptoms associated with cardiac problem and other clinical and laboratory data to reveal correlation with presence of CAD. MPI were assessed visually and semi-quantitatively with C-Equal program. Myocardial ischemia was detected in 52(31%) patients. Among them, 41 had 1-vessel and 9 had 2-vessel disease. In 52 patients with ischemia, 28(54%) were male and 24(46%) were female. 20/68(29%) asymptomatic and 32/101(32%) symptomatic patients had ischemia. Higher prevalence of neuropathy, hypertension, higher blood glucose level, HbA1c and CRP was noted in patients with myocardial ischemia. Serum levels of cholesterol and LDL was not significantly different between patients with ischemia and with normal MPI findings. Abnormal MPI findings were not related with gender and age. These results show a high prevalence of abnormal MPI results in diabetic patients regardless of symptoms. Screening stress MPI in diabetic patients should be indicated irrespective of symptoms, especially in patients with neuropathy, hypertension, higher level of blood glucose, or increased CRP.

  2. Applying the J-optimal channelized quadratic observer to SPECT myocardial perfusion defect detection

    Science.gov (United States)

    Kupinski, Meredith K.; Clarkson, Eric; Ghaly, Michael; Frey, Eric C.

    2016-03-01

    To evaluate performance on a perfusion defect detection task from 540 image pairs of myocardial perfusion SPECT image data we apply the J-optimal channelized quadratic observer (J-CQO). We compare AUC values of the linear Hotelling observer and J-CQO when the defect location is fixed and when it occurs in one of two locations. As expected, when the location is fixed a single channels maximizes AUC; location variability requires multiple channels to maximize the AUC. The AUC is estimated from both the projection data and reconstructed images. J-CQO is quadratic since it uses the first- and second- order statistics of the image data from both classes. The linear data reduction by the channels is described by an L x M channel matrix and in prior work we introduced an iterative gradient-based method for calculating the channel matrix. The dimensionality reduction from M measurements to L channels yields better estimates of these sample statistics from smaller sample sizes, and since the channelized covariance matrix is L x L instead of M x M, the matrix inverse is easier to compute. The novelty of our approach is the use of Jeffrey's divergence (J) as the figure of merit (FOM) for optimizing the channel matrix. We previously showed that the J-optimal channels are also the optimum channels for the AUC and the Bhattacharyya distance when the channel outputs are Gaussian distributed with equal means. This work evaluates the use of J as a surrogate FOM (SFOM) for AUC when these statistical conditions are not satisfied.

  3. Evaluation of {sup 99m}Tc-ECD SPECT for the detection of brain tumor. Comparison with {sup 201}Tl SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Oshima, Motoo; Sasaki, Yasushi; Kikuchi, Yoshirou; Kaminaga, Tatsuro; Furui, Shigeru [Teikyo Univ., Tokyo (Japan). Faculty of Medicine; Konoeda, Kouichi; Karigome, Masato; Yoshida, Katsuhiko

    1997-01-01

    For the evaluation of brain tumor (n=15), we performed both dynamic and static {sup 99m}Tc-ECD (ECD) SPECT studies. {sup 201}Tl SPECT was also used for comparison with the results of ECD SPECT. Dynamic ECD SPECT was obtained following the injection of 600 MBq of ECD. Five min after the injection of ECD, static ECD SPECT was performed. {sup 201}Tl SPECT was obtained 10 min after the injection of 74 MBq. Abnormal uptake was recognized in 7 of 15 tumors with dynamic ECD; 5 of 7 meningiomas, 1 of 1 glioblastoma and 1 of 1 astrocytoma. However, no abnormal uptake was seen in 3 of 3 benign tumors (1 low grade astrocytoma, 1 hemangioma, 1 craniopharyngioma) and in 2 of 2 brain metastases. In contrast abnormal uptake was seen in 11 of 15 tumors with {sup 201}Tl; 7 of 7 meningiomas, 2 of 2 brain metastases, 1 of 1 glioblastoma and 1 of 1 craniopharyngioma. No abnormal uptake was seen in 3 of 3 benign tumors (1 hemangioma and 2 low grade astrocytomas). Equivocal uptake was seen in 1 low grade astrocytoma with dynamic ECD and {sup 201}Tl. The mechanism of the accumulation of dynamic ECD to brain tumor is unclear. However, it may reflect not only blood flow, but also metabolism. (author)

  4. Simple Hydrogen Plasma Doping Process of Amorphous Indium Gallium Zinc Oxide-Based Phototransistors for Visible Light Detection.

    Science.gov (United States)

    Kang, Byung Ha; Kim, Won-Gi; Chung, Jusung; Lee, Jin Hyeok; Kim, Hyun Jae

    2018-02-28

    A homojunction-structured amorphous indium gallium zinc oxide (a-IGZO) phototransistor that can detect visible light is reported. The key element of this technology is an absorption layer composed of hydrogen-doped a-IGZO. This absorption layer is fabricated by simple hydrogen plasma doping, and subgap states are induced by increasing the amount of hydrogen impurities. These subgap states, which lead to a higher number of photoexcited carriers and aggravate the instability under negative bias illumination stress, enabled the detection of a wide range of visible light (400-700 nm). The optimal condition of the hydrogen-doped absorption layer (HAL) is fabricated at a hydrogen partial pressure ratio of 2%. As a result, the optimized a-IGZO phototransistor with the HAL exhibits a high photoresponsivity of 1932.6 A/W, a photosensitivity of 3.85 × 10 6 , and a detectivity of 6.93 × 10 11 Jones under 635 nm light illumination.

  5. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections.

    Science.gov (United States)

    Monteiro, Paulo Henrique Silva; de Souza, Thiago Ferreira; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Mengatti, Jair; de Lima, Mariana da Cunha Lopes; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  6. Influence of attenuation correction and reconstruction techniques on the detection of hypoperfused lesions in brain SPECT studies

    International Nuclear Information System (INIS)

    Ghoorun, S.; Groenewald, W.A.; Baete, K.; Nuyts, J.; Dupont, P.

    2004-01-01

    Full text: Aim: To study the influence of attenuation correction and the reconstruction technique on the detection of hypoperfused lesions in brain SPECT imaging, Material and Methods: A simulation experiment was used in which the effects of attenuation and reconstruction were decoupled, A high resolution SPECT phantom was constructed using the BrainWeb database, In this phantom, activity values were assigned to grey and white matter (ratio 4:1) and scaled to obtain counts of the same magnitude as in clinical practice, The true attenuation map was generated by assigning attenuation coefficients to each tissue class (grey and white matter, cerebral spinal fluid, skull, soft and fatty tissue and air) to create a non-uniform attenuation map, The uniform attenuation map was calculated using an attenuation coefficient of 0.15 cm-1, Hypoperfused lesions of varying intensities and sizes were added. The phantom was then projected as typical SPECT projection data, taking into account attenuation and collimator blurring with the addition of Poisson noise, The projection data was reconstructed using four different methods of reconstruction: (1) filtered backprojection (FBP) with the uniform attenuation map; (2) FBP using the true attenuation map; (3) ordered subset expectation maximization (OSEM) (equivalent to 423 iterations) with a uniform attenuation map; and (4) OSEM with a true attenuation map. Different Gaussian postsmooth kernels were applied to the reconstructed images. Results: The analysis of the reconstructed data was performed using figures of merit such as signal to noise ratio (SNR), bias and variance. The results illustrated that uniform attenuation correction offered slight deterioration (less than 2%) with regard to SNR when compared to the ideal attenuation map. which in reality is not known. The iterative techniques produced superior signal to noise ratios (increase of 5 - 20 % depending on the lesion and the postsmooth) in comparison to the FBP methods

  7. Detecting the transport of materials with axoplasm along the axon at the early stage after phrenic nerve neurotization via SPECT on a rabbit model

    International Nuclear Information System (INIS)

    Xu Wendong; Xu Jianguang; Gu Yudong; Jin Shaojin; Lin Xiangtong

    2003-01-01

    Objective: To study the feasibility of estimating the regenerative quality of transferred phrenic nerve by SPECT. Methods: Two tracers, 131 I-tyrosine and 99 Tc m -methylene diphosphonic acid (MDP) were selected. SPECT compounded with high-energy collimation implement (for 131 I) and low-energy collimation implement (for 99 Tc m ) was used. A rabbit model was set up. 131 I-tyrosine was injected into the normal sciatic nerve and transferred phrenic nerve by micro-syringe. The SPECT scanning was carried out at different intervals. The tracing image of 131 I was used for detecting the material migration along the axon and bone image of 99 Tc m -MDP was used for the bone orientation, these two images were interinfiltrated then. Results: The radioactivity of 131 I-tyrosine could be detected by SPECT, the transportation speed was about 30 mm/d in rabbit's normal sciatic nerve. For phrenic nerve transfer group, the 131 I-tyrosine was transported distally to the anastomotic site along with axoplasm in good regeneration group one month after anastomosis, the transportation speed was 40 mm/d. In scar group, the 131 I-tyrosine was accumulated approximately at the anastomotic site and could not be transported distally. Conclusions: The image of 131 I-tyrosine transported with nerve axoplasm could be displayed by SPECT in vivo. The method could be used to detect the circulation of regenerated axoplasm passing through the anastomotic site at the early stage after nerve transferring operation

  8. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    International Nuclear Information System (INIS)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R.; Lindenau, M.; Stodieck, S.; Fiehler, J.; Heese, O.

    2008-01-01

    Ictal perfusion SPECT with either 9 9mTc-hexamethylpropylene amine oxime (HMPAO) or 9 9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case

  9. Detection of a possible epilepsy focus in a preoperated patient by perfusion SPECT and computer-aided subtraction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Apostolova, I.; Wilke, F.; Clausen, M.; Buchert, R. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Nuclear Medicine; Lindenau, M.; Stodieck, S. [Protestant Hospital Alsterdorf, Hamburg (Germany). Dept. of Neurology and Epileptology; Fiehler, J. [Univ. Medical Center Hamburg-Eppendorf (Germany). Dept. of Neuroradiology; Heese, O. [Univ. Medical Center Hamburg-Eppendorf (Germany). Neurological Surgery

    2008-07-01

    Ictal perfusion SPECT with either {sup 9}9mTc-hexamethylpropylene amine oxime (HMPAO) or {sup 9}9mTc-ethylcysteinate dimer (ECD) has been reported to provide very good sensitivity for the determination of the SOA in fTLE. Sensitivity of interictal perfusion SPECT is much lower. However, interictal perfusion SPECT might enhance the specificity of ictal SPECT findings by improving the discrimination between seizure related local hyperperfusion and intersubject variability of perfusion (physiologic hyperperfusion). In addition, the combination of interictal and ictal perfusion SPECT might provide improved sensitivity compared to ictal SPECT alone, particularly when computer-aided subtraction of ictal and interictal SPECT is used instead of traditional side-by-side visual comparison. The combination of ictal and interictal perfusion SPECT eliminates not only physiological inter-subject variance, but it can also eliminate severe partial volume effects. Computer-aided subtraction analysis appears particularly useful in this case.

  10. Calculation of left ventricular volume and ejection fraction from ECG-gated myocardial SPECT. Automatic detection of endocardial borders by threshold method

    International Nuclear Information System (INIS)

    Fukushi, Shoji; Teraoka, Satomi.

    1997-01-01

    A new method which calculate end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) of the left ventricle from myocardial short axis images of ECG-gated SPECT using 99m Tc myocardial perfusion tracer has been designed. Eight frames per cardiac cycle ECG-gated 180 degrees SPECT was performed. Threshold method was used to detect myocardial borders automatically. The optimal threshold was 45% by myocardial SPECT phantom. To determine if EDV, ESV and LVEF can also be calculated by this method, 12 patients were correlated ventriculography (LVG) for 10 days each. The correlation coefficient with LVG was 0.918 (EDV), 0.935 (ESV) and 0.900 (LVEF). This method is excellent at objectivity and reproductivity because of the automatic detection of myocardial borders. It also provides useful information on heart function in addition to myocardial perfusion. (author)

  11. 99mTc-HL91 SPECT detects the relation between hypoxic changes and radiotherapy response of lung cancer

    International Nuclear Information System (INIS)

    Li Ling; Yu Jinming; Xing Ligang; Zhu Hui; Li Guoliang; Fang Yongcun

    2006-01-01

    Objective: To evaluate relation between hypoxia, hypoxic changes detected by 99m Tc-HL91 SPECT and the response to radiotherapy. Methods: Thirty-five patients with pathologically proven non-small cell lung cancer (NSCLC) treated by three-dimensional conformal radiotherapy were entered into the study. All patients were examined by examined by 99m Tc-HL9l SPECT imaging one or two days before radiotherapy. Twenty patients were monitored during radiotherapy(30-40 Gy) and one or two days after radiotherapy. Anterior', posterior and lateral planar images were collected 2 hours, 4 hours and 6 hours after intravenous injection approximately 740 MBq 99m Tc-HL91. Regions of interest(ROIs) were ch awn in the tumor and contralateral position and the radioactivity ratios of tumor to normal(T/N) were calculated. The response to radiotherapy was evaluated by solid tumor' s effect evaluation criterion (WHO) 3-6 months after radiotherapy. The correlations between T/N before radiotherapy, the T/N changes during radiotherapy and the response to radiotherapy were analyzed. Results: The T/N value gradually decreased before, during and after radiotherapy. The average T/N value before, during and after radiotherapy was 1.56±0.19, 1.40±0.12 and 1.29±0.13, respectively (F=10.13, P=0.010). The lower T/N ratio be- fore radiotherapy, the higher the response rate of radiotherapy (P=0.040). The larger change of T/N ratio before and after radiotherapy resulted in higher radiotherapy response, but with no statistical significance (P>0.05). Conclusions: The hypoxia status and hypoxic changes can be observed by HL91 SPECT imaging during radiotherapy which can predict the response to radiotherapy. (authors)

  12. Detection of breast cancer microcalcification using 99mTc-MDP SPECT or Osteosense 750EX FMT imaging

    International Nuclear Information System (INIS)

    Felix, Dayo D.; Gore, John C.; Yankeelov, Thomas E.

    2015-01-01

    Background: In previous work, we demonstrated the presence of hydroxyapetite (type II microcalcification), HAP, in triple negative MDA-MB-231 breast cancer cells. We used 18 F-NaF to detect these types of cancers in mouse models as the free fluorine, 18 F − , binds to HAP similar to bone uptake. In this work, we investigate other bone targeting agents and techniques including 99m Tc-MDP SPECT and Osteosense 750EX FMT imaging as alternatives for breast cancer diagnosis via targeting HAP within the tumor microenvironment. Methods: Thirteen mice were injected subcutaneously in the right flank with 10 6 MDA-MB-231 cells. When the tumor size reached ~ 0.6 cm 3 , mice (n = 9) were injected with ~ 37 MBq of 99m Tc-MDP intravenously and then imaged one hour later in a NanoSPECT/CT or injected intravenously with 4 nmol/g of Osetosense 750EX and imaged 24 hours later in an FMT (n = 4). The imaging probe concentration in the tumor was compared to that of muscle. Following SPECT imaging, the tumors were harvested, sectioned into 10 μm slices, and underwent autoradiography or von Kossa staining to correlate 99m Tc-MDP binding with HAP distribution within the tumor. The SPECT images were normalized to the injected dose and regions-of-interest (ROIs) were drawn around bone, tumor, and muscle to obtain the radiotracer concentration in these regions in units of percent injected dose per unit volume. ROIs were drawn around bone and tumor in the FMT images as no FMT signal was observed in normal muscle. Results: Uptake of 99m Tc-MDP was observed in the bone and tumor with little or no uptake in the muscle with concentrations of 11.34 ± 1.46 (mean ± SD), 2.22 ± 0.95, and 0.05 ± 0.04 %ID/cc, respectively. Uptake of Osteosense 750EX was also observed in the bone and tumor with concentrations of 0.35 ± 0.07 (mean ± SD) and 0.04 ± 0.01 picomoles, respectively. No FMT signal was observed in the normal muscle. There was no significant difference in the bone-to-tumor ratio between

  13. Brain SPECT

    International Nuclear Information System (INIS)

    Feistel, H.

    1991-01-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG) [de

  14. Gallium-67 scintigraphy and the Heart

    International Nuclear Information System (INIS)

    Garayt, D.

    1987-01-01

    Although gallium-67 was initially used for tumor imaging, clinical studies suggested its potential use as a method of detecting occult inflammatory lesions. The demonstration of diffuse myocardial uptake of gallium-67 during Lyme disease myocarditis is consistent with a pattern of diffuse myocarditis as seen in sarcoid myocarditis. Two cases are presented. A critical review of the various applications of gallium-67 scintigraphy to myocardium investigation is carried out [fr

  15. Early detection of drug-induced pneumonitis by gallium-67 lung scan in six patients with normal chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, H; Sawa, H; Takashima, S [Osaka City Univ. (Japan). Hospital

    1981-06-01

    Increased pulmonary accumulation of Gallium-67-citrate was observed in 6 patients (4 with malignant lymphoma, 1 with uterine cancer and 1 with acute myelocytic leukemia) preceding the appearance of any abnormal findings in both chest X-ray and blood gas data. All of them had received multiple courses of chemotherapy. In these patients, the anticancer drugs were administered for 13 to 22 weeks (mean 15 weeks). One patient with malignant lymphoma showed abnormal /sup 67/Ga lung uptake greater than hepatic activity, 3 patients (malignant lymphoma, 2 and uterine cancer, 1) visualized abnormal /sup 67/Ga lung uptake equal to hepatic activity and 2 cases (malignant lymphoma, 1 and acute myelocytic leukemia, 1) demonstrated abnormal accumulation of /sup 67/Ga in the lung greater than background activity. In 4 patients (3 with malignant lymphoma and 1 with uterine cancer) out of 6, transbronchial lung biopsy obtained after the /sup 67/Ga scans showed non-specific interstitial pneumonitis with infiltration of lymphocytes and macrophages compatible with drug-induced pneumonitis. In the other 2 patients, cytology and cultures were negative and follow up /sup 67/Ga lung scans revealed a reduction in intensity of uptake after treatment with corticosteroid. Therefore, we considered that the /sup 67/Ga lung scan was useful for early detection of drug-induced pneumonitis.

  16. Collimator optimization in myocardial perfusion SPECT using the ideal observer and realistic background variability for lesion detection and joint detection and localization tasks

    Science.gov (United States)

    Ghaly, Michael; Du, Yong; Links, Jonathan M.; Frey, Eric C.

    2016-03-01

    In SPECT imaging, collimators are a major factor limiting image quality and largely determine the noise and resolution of SPECT images. In this paper, we seek the collimator with the optimal tradeoff between image noise and resolution with respect to performance on two tasks related to myocardial perfusion SPECT: perfusion defect detection and joint detection and localization. We used the Ideal Observer (IO) operating on realistic background-known-statistically (BKS) and signal-known-exactly (SKE) data. The areas under the receiver operating characteristic (ROC) and localization ROC (LROC) curves (AUCd, AUCd+l), respectively, were used as the figures of merit for both tasks. We used a previously developed population of 54 phantoms based on the eXtended Cardiac Torso Phantom (XCAT) that included variations in gender, body size, heart size and subcutaneous adipose tissue level. For each phantom, organ uptakes were varied randomly based on distributions observed in patient data. We simulated perfusion defects at six different locations with extents and severities of 10% and 25%, respectively, which represented challenging but clinically relevant defects. The extent and severity are, respectively, the perfusion defect’s fraction of the myocardial volume and reduction of uptake relative to the normal myocardium. Projection data were generated using an analytical projector that modeled attenuation, scatter, and collimator-detector response effects, a 9% energy resolution at 140 keV, and a 4 mm full-width at half maximum (FWHM) intrinsic spatial resolution. We investigated a family of eight parallel-hole collimators that spanned a large range of sensitivity-resolution tradeoffs. For each collimator and defect location, the IO test statistics were computed using a Markov Chain Monte Carlo (MCMC) method for an ensemble of 540 pairs of defect-present and -absent images that included the aforementioned anatomical and uptake variability. Sets of test statistics were

  17. Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease

    International Nuclear Information System (INIS)

    Hsu, Bailing; Chen, Fu-Chung; Chen, Chien-Cheng; Wu, Tao-Cheng; Huang, Wen-Sheng; Hou, Po-Nien; Hung, Guang-Uei

    2014-01-01

    Conventional dual-head single photon emission computed tomography (SPECT)/CT systems capable of fast dynamic SPECT (DySPECT) imaging have a potential for flow quantitation. This study introduced a new method to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) with DySPECT scan and evaluated the diagnostic performance of detecting coronary artery disease (CAD) compared with perfusion using invasive coronary angiography (CAG) as the reference standard. This study included 21 patients with suspected or known CAD who had received DySPECT, ECG-gated SPECT (GSPECT), and CAG (13 with ≥50 % stenosis in any vessel; non-CAD group: 8 with patent arteries or 99m Tc-sestamibi (MIBI) tracer at rest or dipyridamole-stress stages. DySPECT images were reconstructed with full physical corrections and converted to the physical unit of becquerels per milliliter. Stress MBF (SMBF), rest MBF (RMBF), and MFR were quantified by a one-tissue compartment flow model using time-activity curves derived from DySPECT images. Perfusion images were processed for GSPECT scan and interpreted to obtain summed stress score (SSS) and summed difference score (SDS). Receiver-operating characteristic (ROC) analyses were conducted to evaluate the diagnostic performance of flow and perfusion. Using the criteria of ≥50 % stenosis as positive CAD, areas under the ROC curve (AUCs) of flow assessment were overall significantly greater than those of perfusion. For patient-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.91 ± 0.07, 0.86 ± 0.09, 0.64 ± 0.12, and 0.59 ± 0.13. For vessel-based analysis, AUCs for MFR, SMBF, SSS, and SDS were 0.81 ± 0.05, 0.76 ± 0.06, 0.62 ± 0.07, and 0.56 ± 0.08, respectively. The preliminary data suggest that MBF quantitation with a conventional SPECT/CT system and the flow quantitation method is a clinically effective approach to enhance CAD detection. (orig.)

  18. Evaluation of a CZT gamma-ray detection module concept for SPECT

    International Nuclear Information System (INIS)

    Montemont, Guillaume; Lux, Silvere; Monnet, Olivier; Stanchina, Sylvain; Verger, Loick

    2012-01-01

    CZT detectors are the basic building block of a variety of new SPECT systems. Their modularity allows to adapt system architecture to specific applications such as cardiac, breast, brain or small animal imaging. Thanks to their high quantum yield, these direct conversion detectors exhibit better energy and spatial resolutions than usual scintillation detectors based on NaI(Tl). However, it remains often unclear if SPECT imaging really can take profit of that performance gain. We propose here to conduct a case study based on the latest results obtained in our laboratory with current state of the art ICs and CZT crystals to investigate the system performance of a classical module dimensioning of 5 mm thick CZT with a segmented anode at a 2.5 * 2.5 mm pitch. This dimensioning, though being quite conservative, allows an easy integration in terms of crystal hybridization or PCB layout but still allows to obtain impressive results. Compared with X-ray counting were the only information retrieved is the occurrence of a photon interaction, spectrometric imaging performance is not only determined by photon statistics but also by readout noise, that ultimately limits time, energy and spatial resolutions associated with each photon event. After a first part dealing with the noise performance achieved by integrated circuits and a discussion on the key limiting factors, we present the typical readout architecture used and show how the signal processing is optimized for multiple parameter estimation. In a subsequent part, multi-pixel data acquisition scheme is discussed to show how raw channel data is used to extract photon parameters (energy, time-stamp, and 3D position) while taking into account material non-uniformities. We will show how such data can be used to build images and quantify resulting improvement. Finally, we open the discussion on SPECT collimation and architecture by demonstrating with simulations how a tomographical system dimensioning depends on detector

  19. The Diagnostic Efficiency of 99mTc-EDDA/HYNIC-Octreotate SPECT-CT in Comparison with 111In-Pentetrotide in the Detection of Neuroendocrine Tumours

    Directory of Open Access Journals (Sweden)

    Emel Koçyiğit Deveci

    2013-12-01

    Full Text Available Objective: The aim of this study was to assess the diagnostic efficiency of 99mTc-EDDA/HYNIC-Octreotate in comparison with 111Inpentetrotide scintigraphy in the detection of neuroendocrine tumors. This study also evaluates the impact of SPECT-CT hybrid imaging on somatostatin receptor scintigraphy (SRS interpretation and clinical management of these tumors. Methods: Fourteen patients were included in the study. All patients underwent a whole body and SPECT-CT imaging with both 99mTcEDDA/HYNIC-octreotate and 111In-pentetrotide. Images were evaluated both visually and semiquantitatively. Results: On patient basis, the diagnostic results of both studies were similar. The number of lesions detected by 99mTc- EDDA/HYNICOctreotate were higher than the number of lesions detected by 111In-pentetrotide however the difference was not significant (40/43( 93%, 36/43 (83% p=0.109. Semiquantitative analysis showed higher tumor/organ count ratios for both whole-body and SPECT 99mTc- EDDA/HYNIC-Octreotate scans. Conclusion: The results of this study suggested that, 99mTc- EDDA/HYNIC-Octreotate may be a better alternative to 111In- pentetrotide due to high image quality and lower radiation dose. SPECT/CT is a valuable tool for the assessment of neuroendocrine tumors by providing the precise anatomic localization of scintigraphic findings thus improving lesion detectability and characterization.

  20. The Diagnostic Efficiency of 99mTc-EDDA/HYNIC-Octreotate SPECT-CT in Comparison with 111In-Pentetrotide in the Detection of Neuroendocrine Tumours.

    Science.gov (United States)

    Koçyiğit Deveci, Emel; Ocak, Meltem; Bozkurt, Murat Fani; Türker, Selcan; Kabasakal, Levent; Uğur, Omer

    2013-12-01

    The aim of this study was to assess the diagnostic efficiency of (99m)Tc-EDDA/HYNIC-Octreotate in comparison with (111)Inpentetrotide scintigraphy in the detection of neuroendocrine tumors. This study also evaluates the impact of SPECT-CT hybrid imaging on somatostatin receptor scintigraphy (SRS) interpretation and clinical management of these tumors. Fourteen patients were included in the study. All patients underwent a whole body and SPECT-CT imaging with both (99m)Tc- EDDA/HYNIC-octreotate and (111)In-pentetrotide. Images were evaluated both visually and semiquantitatively. On patient basis, the diagnostic results of both studies were similar. The number of lesions detected by (99m)Tc- EDDA/HYNICOctreotate were higher than the number of lesions detected by (111)In-pentetrotide however the difference was not significant (40/43( 93%), 36/43 (83%) p=0.109). Semiquantitative analysis showed higher tumor/organ count ratios for both whole-body and SPECT (99m)Tc- EDDA/HYNIC-Octreotate scans. The results of this study suggested that, (99m)Tc- EDDA/HYNIC-Octreotate may be a better alternative to (111)In- pentetrotide due to high image quality and lower radiation dose. SPECT/CT is a valuable tool for the assessment of neuroendocrine tumors by providing the precise anatomic localization of scintigraphic findings thus improving lesion detectability and characterization. None declared.

  1. Chilaiditi's syndrome demonstrated by SPECT/CT

    Directory of Open Access Journals (Sweden)

    Nalini S Perumal

    2009-11-01

    Full Text Available Purpose: Chilaiditi’s syndrome is a rare condition commonly diagnosed as an incidental radiological finding. The aim of this report is to show the role of SPECT-CT in this syndrome and state the functional and anatomical role of this hybrid imaging modality. Materials and Methods: A case report. Results: A 49-year-old female patient was referred for gallium-67 citrate for a possible granulomatous myositis and underwent SPECT-CT of the abdomen to assess the area of decreased gallium uptake on planar images of the liver. The combined SPECT and CT modality demonstrated findings consistent with the clinical evidence of Chilaiditi’s syndrome. The anatomical part of this hybrid modality made it easier to evaluate the area of gallium lack of uptake which was due to air in the colon. Conclusion: This case does not only show the role of SPECT-CT in this syndrome but also suggest that the use of such modality should be considered whenever available in the evaluation of patients in whom the localization of active disease becomes imperative.

  2. ROC evaluation of SPECT myocardial lesion detectability with and without single iteration non-uniform Chang attenuation compensation using an anthropomorphic female phantom

    International Nuclear Information System (INIS)

    Jang, S.; Jaszczak, R.J.; Duke Univ. Medical Center, Durham, NC; Gilland, D.R.; Turkington, T.G.; Coleman, R.E.; Tsui, B.M.W.; Metz, C.E.

    1998-01-01

    The purpose of this work was to evaluate lesion detectability with and without nonuniform attenuation compensation (AC) in myocardial perfusion SPECT imaging in women using an anthropomorphic phantom and receiver operating characteristics (ROC) methodology. Breast attenuation causes artifacts in reconstructed images and may increase the difficulty of diagnosis of myocardial perfusion imaging in women. The null hypothesis tested using the ROC study was that nonuniform AC does not change the lesion detectability in myocardial perfusion SPECT imaging in women. The authors used a filtered backprojection (FBP) reconstruction algorithm and Chang's single iteration method for AC. In conclusion, with the proposed myocardial defect model nuclear medicine physicians demonstrated no significant difference for the detection of the anterior wall defect; however, a greater accuracy for the detection of the inferior wall defect was observed without nonuniform AC than with it. Medical physicists did not demonstrate any statistically significant difference in defect detection accuracy with or without nonuniform AC in the female phantom

  3. Hepatic hemangioma. Comparison between MR and SPECT in its detection and characterization

    International Nuclear Information System (INIS)

    Galant Herrero, J.; Marti-Bonmati, L.; Sopena Monforte, R.; Caballero Calabuig, E.; Martinez Rodrigo, J.; Ferrer Puchol, D.; Paniagua Escudero, J.C.

    1993-01-01

    Given the high prevalence of hepatic hemangioma, diagnostic techniques that differentiate these benign lesions from metastasis, hepatoma, and other malignant diseases are necessary. Twenty-five consecutive patients in whom ultrasonography led to the suspicion of hemangioma were studied by magnetic resonance (MR) and tomographic scintigraphy using 99m Tc-labeled red blood cells. Twenty patients presented 42 hemangiomas. Of the 5 remaining patients, 2 proved to have hepatoma and 3 had metastases. Both MR and SPECT have been shown to be highly sensitive in the diagnosis of hepatic hemangioma (95% and 74%, respectively). The specificity of both techniques was 100%. A diagnostic algorithm is presented, based on the high sensitivity and specificity of the two techniques for the purpose of avoiding unnecessary diagnostic measures. (Author)

  4. 99MTC-HL91 spect image versus 18F-FDG PET for detection of head and neck carcinoma

    International Nuclear Information System (INIS)

    Chu, L.S.; Liu, R.S.; Chou, K.L.; Yang, B.H.; Liao, S.Q.; Yeh, S.H.

    2004-01-01

    Objective: Tumor hypoxia is a major complication of oncologic cell switch for chemotherapy(C/T) and / or radiotherapy(R/T). Such lesions detected by selective modem conventional examination remains difficult. 99mTc-HL91 is a potential agent for imaging hypoxic tissue in vivo. This study aimed to assess efficacy of 99mTc- HL91 in imaging of head and neck cancer and compared the result with 18F-fluorodeoxyglucose(FDG)PET. Methods: Sixteen pts with head and neck cancers (7 hypopharyngeal cancers, 4 laryngeal cancers, 5 tongue base cancers) were enrolled in this study. Primary tumors and suspicious local,regional metastases were diagnosed by clinical examination, CT/MRI , and biopsy. After intravenous injection of 740 MBq of 99mTc-HL91, whole body planar scan and regional SPECT at 2hr postinjection were performed. Tumor lesion -to- normal background(T/N) ratios with 3x3 pixels of background ROI were also measured. The reference range of T/N ratio greater 3.0 defined +, close to 2.4 defined +/- and less than 1.5 defined as -. The FDG images with dedicated PET system was performed at 4hr after completion of 99mTc-HL91 study. The visualized tumors uptake with ratio of standardized uptake value (SUV) greater than 2.5 defined as +.. less than 2.5 defined -. Results: In 7 hypopharyngeal cancers, there are 2FDG+/HL91+, 3FDG+/HL91-, 2FDG+/HL91+/-, In 4 laryngeal cancers, there are 3FDG+/HL91-, 1FDG+/HL91 +/-. In 5 tongue base cancers, there are 5FDG+/HL91-.(Table 1). The T/N ratios of all head and neck cancers in primary tumor and regional lymph nodes were ranged from l.3/1.5 and 1.1/1.2 respectively. The frequency of FDG + in hypopharyngeal cancers is 1.0,in laryngeal cancers is 1.0 and in tongue base cancers is 1.0. The frequency of HL91+/+/- in hypopharyngeal cancers is 0..58,in laryngeal cancers is 0.25.and in tongue base cancers is 0. The overall detection rate of head and neck cancer by FDG+ in this study is 100% and overall detection rate of local-regional hypoxia, by

  5. Patent hepatic falciform artery detected after Tc-99m-macroaggregated albumin injection on SPECT/CT prior to Yttrium-90 microsphere radioembolization: a case report

    International Nuclear Information System (INIS)

    Karaman, B.; Aslan, A.; Hamcan, S.; Ugurel, M.

    2012-01-01

    Full text: Introduction: Yttrium-90 (Y-90) microsphere radioembolization is increasingly used for the treatment of unresectable hepatocellular carcinoma and liver metastasis. Objectives and tasks: We aim to present the upper abdominal wall skin involvement detected during routine pre-therapy Technetium-99m-macroaggregated albumin (Tc-99m-MAA) on SPECT/CT due to patent hepatic falciform artery and the precautions to avoid this potential complication. Material and methods: 38-year-old male with colon cancer and multiple liver metastasis was evaluated prior to radioembolization and Tc-99 MAA was slowly hand injected at the bifurcation of the proper hepatic artery. Then, the SPECT/CT scan was performed in order to investigate the systemic shunt or gastric involvement. Results: On SPECT/CT scan, involvement of the upper abdominal wall through falciform ligament was seen. Re-evaluation of the hepatic angiogram identified a patent hepatic falciform artery arising from the left hepatic artery. Y-90 microspheres were slowly hand injected to the left hepatic artery superselectively and no extra-hepatic activity was seen on SPECT/CT scan. Conclusion: Upper abdominal pain and dermatitis are uncommon findings after radioembolization and may occur due to inadvertent delivery of Y-90 microspheres into patent hepatic falciform artery. To prevent these complications, either patent hepatic falciform artery must be embolized by coil or Y-90 injection must be performed superselectively

  6. Comparison of 131I whole-body imaging, 131I SPECT/CT, and 18F-FDG PET/CT in the detection of metastatic thyroid cancer

    International Nuclear Information System (INIS)

    Oh, Jong-Ryool; Chong, Ari; Kim, Jahae; Kang, Sae-Ryung; Song, Ho-Chun; Bom, Hee-Seung; Byun, Byung-Hyun; Hong, Sun-Pyo; Yoo, Su-Woong; Kim, Dong-Yeon; Min, Jung-Joon

    2011-01-01

    The aim of this study was to compare 131 I whole-body scintigraphy (WBS), WBS with 131 I single photon emission computed tomography/computed tomography (SPECT/CT), and 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in the detection of distant metastases of differentiated thyroid cancer (DTC). A total of 140 patients with 258 foci of suspected distant metastases were evaluated. 131 I WBS, 131 I SPECT/CT, and 18 F-FDG PET/CT images were interpreted separately. The final diagnosis was obtained from histopathologic study, serum thyroglobulin level, other imaging modalities, and/or clinical follow-up. Of the 140 patients with 258 foci, 46 patients with 166 foci were diagnosed as positive for distant metastasis. The sensitivity, specificity, and diagnostic accuracy of each imaging modality were 65, 55, and 59%, respectively, for 131 I WBS; 65, 95, and 85% for 131 I SPECT/CT, respectively; and 61, 98, and 86%, respectively, for 18 F-FDG PET/CT in patient-based analyses. Lesion-based analyses demonstrated that both SPECT/CT and PET/CT were superior to WBS (p 18 F-FDG PET/CT presented the highest diagnostic performance in patients who underwent multiple challenges of radioiodine therapy. (orig.)

  7. Comparison of CTAC and prone imaging for the detection of coronary artery disease using CZT SPECT.

    Science.gov (United States)

    Ito, Shimpei; Endo, Akihiro; Okada, Taiji; Nakamura, Taku; Sugamori, Takashi; Takahashi, Nobuyuki; Yoshitomi, Hiroyuki; Tanabe, Kazuaki

    2017-10-01

    Cadmium-zinc-telluride (CZT) cameras have improved the evaluation of patients with chest pain. However, inferior/inferolateral attenuation artifacts similar to those seen with conventional Anger cameras persist. We added prone acquisitions and CT attenuation correction (CTAC) to the standard supine image acquisition and analyzed the resulting examinations. Seventy-two patients referred for invasive coronary angiography (CAG), and who also underwent rest/stress myocardial perfusion imaging (MPI) on a CZT camera in the supine and prone positions plus CTAC imaging, to examine known or suspected CAD between April 2013 and March 2014 were included. A sixteen-slice CT scan acquired on a SPECT/CT scanner between rest and stress imaging provided data for iterative reconstruction. Sensitivity, specificity, accuracy, and positive and negative likelihood ratios (LRs) were calculated to compare MPI with CAG on a per-patient basis. Per-patient sensitivity, specificity, and accuracy of supine images to predict coronary abnormalities on CAG were 35% [95% confidence interval (CI) 19-52], 86% (95% CI 80-92), and 74% (95% CI 66-82); those of prone imaging were 65% (95% CI 45-81), 82% (95% CI 76-87), and 78% (95% CI 68-85); and those of CTAC were 59% (95% CI 41-71), 93% (95% CI 87-97), and 85% (95% CI 76-91), respectively. Prone acquisition and CTAC images improve the ability to assess the inferior/inferolateral area.

  8. Gallium-67 citrate scan in extrapulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Lin Wanyu [Taichung Veterans General Hospital (Taiwan). Dept. of Nuclear Medicine; Hsieh Jihfang [Chi-Mei Foundation Hospital, Tainan (Taiwan)

    1999-07-01

    Aim: Whole-body gallium scan was performed to evaluate the usefulness of gallium scan for detecting extrapulmonary tuberculosis (TB) lesions. Methods: Thirty-seven patients with extrapulmonary TB were included in this study. Four patients were found to have two lesions. Totally, 41 lesions were identified, including 19 TB arthritis, 8 spinal TB, 5 TB meningitis, 3 TB lymphadenopathy, 2 TB pericarditis, 1 TB peritonitis, 1 intestinal TB, 1 skin TB and 1 renal TB. Results: Of the 41 extrapulmonary TB lesions, gallium scan detected 32 lesions with a sensitivity of 78%. All the patients with TB meningitis showed negative gallium scan. When the five cases of TB meningitis were excluded, the detection sensitivity of gallium scan increased to 88.9% (32/36). Conclusion: Our data revealed that gallium scan is a convenient and useful method for evaluating extrapulmonary TB lesions other than TB-meningitis. We suggest that gallium scan be included in the clinical routine for patients with suspected extrapulmonary TB. (orig.) [German] Ziel: Es wurden Ganzkoerper-Gallium-Szintigramme angefertigt, um den Nutzen der Gallium-Szintigraphie zur Erfassung von extrapulmonalen Tuberkuloseherden (TB) zu erfassen. Methoden: 37 Patienten mit extrapulmonaler TB wurden eingeschlossen. 4 Patienten hatten 2 Laesionen. Insgesamt wurden 41 Laesionen identifiziert, hierunter 19 TB-Arthritis, 8 spinale TB, 5 TB-Meningitis, 3 TB-Lymphadenopathie, 2 TB-Perikarditis, 1 TB-Peritonitis, 1 intestinale TB, 1 Haut-TB und eine Nieren-TB. Ergebnisse: Von den 41 extrapulmonalen TB-Herden erfasste die Gallium-Szintigraphie 32 Herde mit einer Sensitivitaet von 78%. Alle Patienten mit TB-Meningitis zeigten einen negativen Gallium-Scan. Wenn die 5 Faelle mit TB-Meningitis ausgeschlossen wurden, stieg die Sensitivititaet der Gallium-Szintigraphie auf 88,9% (32/36). Schlussfolgerung: Die Daten zeigen, dass die Gallium-Szintigraphie eine einfache und nuetzliche Methode zur Erfassung extrapulmonaler TB-Herde ist

  9. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  10. Comparison of Diagnostic Accuracy for Detecting coronary Artery Disease of Dipyridamole 99mTc-MIBI Myocardial SPECT and It's Defect Map between Men and Women

    International Nuclear Information System (INIS)

    Lee, Dong Soo; Oh, Byung Hee; Chung, June Key; Lee, Myoung Mook; Park, Young Bae; Lee, Myung Chul; Seo, Jung Don; Lee, Young Woo; Koh, Chang Soon

    1993-01-01

    To evaluate the usefulness and differences in diagnosing coronary artery disease (CAD) between men and women of intravenous dipyridamole 99m Tc-MIBI myocardial SPECT, we obtained 99m Tc-MIBI myocardial SPECT and compared with the findings of coronary angiographies. Ninety eight male and 37 female patients who underwent dipyridamole 99m Tc- MIBI myocardial imaging within one month of cardiac catheterization were studied. Scans were considered abnormal if perfusion defect was detected and the defect size was more than 12% for left anterior descending artery (LAD) and circumflex(LCX) and 8% for right coronary artery (RCA) territories. Lesions ≥ 50% luminal diameter narrowing were considered significant CAD. Overall sensitivity for detection of CAD was 94.3% in men and 96.4% in women; specificity was 70% in men and 52.6% in women (P=not significant, ns). Vessel-matched sensitivity was 75.3% in men and 72.7% in women (P=ns); specificity was 84.6% in men and 67.9% in women (P 99m Tc-MIBI myocardial SPECT is a safe, noninvasive test for evaluation of CAD. There was no gender difference to detect CAD, but more false-positive rate in women especially in the territory of LAD.

  11. Detection of tumor recurrence using technetium99m-tetrofosmin brain SPECT in patients with previously irradiated brain tumors

    International Nuclear Information System (INIS)

    Llamas A; Reyes A; Uribe, L F; Martinez T

    2004-01-01

    Objective: to assess the clinical utility of brain SPECT with Tc-99m Tetrofosmin to differentiate between tumor recurrence and radionecrosis in patients with primary brain tumors previously treated with external beam radiotherapy. Materials and methods: thirteen patients with clinical or radiological suspicion of tumor recurrence were studied with brain SPECT using 20-mCi of Tc-99m Tetrofosmin. Obtained images were interpreted by consensus between two experienced observers and subsequently classified as positive or negative for tumor viability. Results were compared to those of conventional diagnostic imaging techniques. Diagnostic test values and 95% confidence intervals were quantified. Results: SPECT results included 7 true-positives, 5 true-negatives and 1 false negative result. Conclusions: Tc-99m Tetrofosmin brain SPECT night be a useful alternative to diagnose recurrent brain tumors, especially with non-conclusive clinical and radiological findings

  12. Interest of the SPECT-CT merging to detect pseudo-arthrosis after lumbar arthrodesis: preliminary results; Interet de la fusion TEMP-TDM pour la detection des pseudarthroses apres arthrodese lombaire: resultats preliminaires

    Energy Technology Data Exchange (ETDEWEB)

    Rager, O.; Ratib, O.; Tessitore, E. [Hopitaux universitaire de Geneve (Switzerland)

    2010-07-01

    Pseudo arthrosis is a potential complication after a lumbar arthrodesis. The symptoms are nonspecific and revision surgery is not always an effective treatment. Scintigraphy SPECT / CT with {sup 99m}Tc and CT were studied separately for the diagnosis of pseudo arthrosis before the widespread use of software fusion. It is well established that the diagnosis based on CT led to a number of false positive (10%). The purpose of this study is to evaluate the usefulness of SPECT-CT fusion imaging in the diagnosis of pseudo arthrosis. Conclusions: SPECT / CT fusion imaging may increase the specificity for the diagnosis of pseudo arthrosis at the level of inter body cages and increase sensitivity for the detection of degenerative diseases on the back joints. (N.C.)

  13. Gallium-67 citrate scan in extrapulmonary tuberculosis

    International Nuclear Information System (INIS)

    Lin Wanyu

    1999-01-01

    Aim: Whole-body gallium scan was performed to evaluate the usefulness of gallium scan for detecting extrapulmonary tuberculosis (TB) lesions. Methods: Thirty-seven patients with extrapulmonary TB were included in this study. Four patients were found to have two lesions. Totally, 41 lesions were identified, including 19 TB arthritis, 8 spinal TB, 5 TB meningitis, 3 TB lymphadenopathy, 2 TB pericarditis, 1 TB peritonitis, 1 intestinal TB, 1 skin TB and 1 renal TB. Results: Of the 41 extrapulmonary TB lesions, gallium scan detected 32 lesions with a sensitivity of 78%. All the patients with TB meningitis showed negative gallium scan. When the five cases of TB meningitis were excluded, the detection sensitivity of gallium scan increased to 88.9% (32/36). Conclusion: Our data revealed that gallium scan is a convenient and useful method for evaluating extrapulmonary TB lesions other than TB-meningitis. We suggest that gallium scan be included in the clinical routine for patients with suspected extrapulmonary TB. (orig.) [de

  14. Comparison of Nitrate-augmented resting gated 99mTc-Sestamibi imaging with Low Dose Dobutamine SPECT for the detection of Myocardial Viability

    International Nuclear Information System (INIS)

    Parameswaran, R.V.; Dash, P.K.; Barooah, B.; Guruprasad, H.P.; Purantharan, N.

    2002-01-01

    Background: Dobutamine Echocardiography and Radionuclide imaging with Tl-201 and Technetium agents are two of the most established techniques available for the detection of viable myocardium. The purpose of this study was to evaluate the utility of Low dose Dobutamine gated Myocardial SPECT in identifying additional areas of dysfunctional, but viable myocardium when compared to nitrate-augmented rest gated SPECT with SestaMIBI. Materials and Methods: 20 patients (19 males and 1 female, with an age range of 40- 65 yrs and a mean of 52.75yrs) all with history of MI or severe LV dysfunction were included in this study. Patients with LBBB, recent revascularisation, arrhythmias etc were excluded from the study. A routine stress-rest study was initially performed on them with 99mTc-SestaMIBI and both the stress as well as resting studies was gated and the resting study was augmented with 10mg of sublingual nitrate. After the resting study was over, the patient was infused with Low dose Dobutamine(5μg/kg/min), at which time the gated acquisition was started and the infusion was continued till the acquisition got completed. In the perfusion study with SestaMIBI, all infarct segments which have uptake less than 50% as compared to the maximally perfused area was deemed non-viable Results: A 17-segment Myocardial model was used for both perfusion as well as quantification of wall motion and wall thickening. 110 akinetic/dyskinetic segments were taken up for analysis. 93 of these segments were non-viable and improvement in wall motion was seen in 17 segments (15.4%) in the nitrate-augmented SPECT. Dobutamine study showed improvement in totally in 27 segments (24.5%), 10 of which were additional segments which were non-viable in Nitrate SPECT study, apart from the 17 segments which showed improvement in the Nitrate study. In Dobutamine study, there was also improvement in wall thickening in 10 (10.7%) out of 93 segments which had showed less than 50% of MIBI uptake. Conclusion

  15. Role of stress myocardial perfusion SPECT scan in detection and management of coronary artery disease: Nairobi experience

    International Nuclear Information System (INIS)

    Makhdomi, K.B.; Warshow, M.M.; Patel, P.K.J.; Shah, D.; Githegi, D.R.M.

    2002-01-01

    Aim: Stress myocardial perfusion scans have acquired a significant role in the detection and management of Coronary Artery Disease. However, this mode of investigation has only recently been available in Nairobi, and this is the first such study from East Africa. We undertook a comparison of our results with that in the literature, to see whether they conformed to it. Materials and Methods: We performed a review of our initial 82 evaluable studies. The scans were performed with 99mTc-Tetrofosmin, using the single day stress-rest protocol with SPECT acquisitions. We carried out a correlation of our scan findings with angiographic data (where available), and clinical follow-up. The clinical end points where furnished by the referring physicians. We focused on myocardial infarction, need for re-vascularisation, and death. The mean clinical follow-up was 21.8 months (range of 12 months to 39 months). Results: Eighty (98%) of the studies revealed concordance with angiographic findings and/or were predictive of clinical outcome. Two studies were discordant, and will be discussed. The results are comparable with those in the literature. Conclusion: It is concluded that stress myocardial perfusion studies, done at our Centre, had a good predictive value, with regards to the presence and severity of disease, and correlated with the clinical outcome data

  16. The impact of noisy and misaligned attenuation maps on human-observer performance at lesion detection in SPECT

    Science.gov (United States)

    Wells, R. G.; Gifford, H. C.; Pretorius, P. H.; Famcombe, T. H.; Narayanan, M. V.; King, M. A.

    2002-06-01

    We have demonstrated an improvement due to attenuation correction (AC) at the task of lesion detection in thoracic SPECT images. However, increased noise in the transmission data due to aging sources or very large patients, and misregistration of the emission and transmission maps, can reduce the accuracy of the AC and may result in a loss of lesion detectability. We investigated the impact of noise in and misregistration of transmission data, on the detection of simulated Ga-67 thoracic lesions. Human-observer localization-receiver-operating-characteristic (LROC) methodology was used to assess performance. Both emission and transmission data were simulated using the MCAT computer phantom. Emission data were reconstructed using OSEM incorporating AC and detector resolution compensation. Clinical noise levels were used in the emission data. The transmission-data noise levels ranged from zero (noise-free) to 32 times the measured clinical levels. Transaxial misregistrations of 0.32, 0.63, and 1.27 cm between emission and transmission data were also examined. Three different algorithms were considered for creating the attenuation maps: filtered backprojection (FBP), unbounded maximum-likelihood (ML), and block-iterative transmission AB (BITAB). Results indicate that a 16-fold increase in the noise was required to eliminate the benefit afforded by AC, when using FBP or ML to reconstruct the attenuation maps. When using BITAB, no significant loss in performance was observed for a 32-fold increase in noise. Misregistration errors are also a concern as even small errors here reduce the performance gains of AC.

  17. Clinical evaluation of stress thallium spect in ischemic heart disease

    International Nuclear Information System (INIS)

    Sui, Osamu; Kimura, Nazuna; Soeki; Takeshi; Takeichi, Naoki; Shinohara, Hisanori; Tamura, Yoshiyuki; Fukuda, Nobuo

    1997-01-01

    Thallium SPECT was performed in patients with significant coronary artery stenosis, 67 cases were after maximal exercise and 74 cases were during coronary vasodilation induced by ATP (adenosine triphosphate) infusion. In patients suspected of angina pectoris, the sensitivity, specificity and predictive accuracy for detection of coronary artery disease (CAD) were 88%, 78% and 82% for exercise SPECT, and 100%, 72% and 84% for ATP SPECT studies, respectively. In patients with old myocardial infarction, these were 73%, 100% and 88% for exercise SPECT and 71%, 100% and 81% for ATP SPECT. These were 75%, 49% and 60% for treadmill exercise test in the patient group including both angina and myocardial infarction. For detection of diseased vessels, the diagnostic accuracy for left anterior descending artery and right coronary artery lesions was almost equal for ATP and exercise SPECT study, but ATP SPECT study was more sensitive than exercise SPECT study in detection of left circumflex artery lesions. ATP as well as exercise SPECT studies occasionally gave false positive results in patients with single-vessel disease. ATP as well as exercise SPECT studies underestimated the severity of multi-vessel disease. In general, the results of ATP SPECT imaging were highly concordant with the results of exercise SPECT imaging. ATP stress thallium SPECT imaging provided a safe and highly accurate diagnostic tool for detection of CAD. (author)

  18. Metastasectomy of Abdominal Wall Lesions due to Prostate Cancer Detected Through PET/CT Gallium 68-PMSA: First Case Report.

    Science.gov (United States)

    Ochoa, Claudia; Ramirez, Angie; Varela, Rodolfo; Godoy, Fabian; Vargas, Rafael; Forero, Jorge; Rojas, Andres; Roa, Carmen; Céspedes, Carlos; Ramos, Jose; Cabrera, Marino; Calderon, Andres

    2017-05-01

    Introducing the topic of abdominal wall metastasis secondary to prostate cancer with a reminder of the disease's rarity, being the first published case. This article is about a 66 year old patient diagnosed with prostate cancer [cT2aNxMx iPSA: 5,6 ng/ml Gleason 3+3, (Grade 1 Group)], treated with radical prostatectomy as well as accompanied with amplified pelvic lymphadenectomy, who subsequently presented metastatic lesions to the abdominal wall diagnosed with PET/CT Gallium 68-PMSA technique and treated with abdominal metastasectomy with adequate short term results.

  19. Metastasectomy of Abdominal Wall Lesions due to Prostate Cancer Detected Through PET/CT Gallium 68-PMSA: First Case Report

    Directory of Open Access Journals (Sweden)

    Claudia Ochoa

    2017-05-01

    Full Text Available Introducing the topic of abdominal wall metastasis secondary to prostate cancer with a reminder of the disease's rarity, being the first published case. This article is about a 66 year old patient diagnosed with prostate cancer [cT2aNxMx iPSA: 5,6 ng/ml Gleason 3+3, (Grade 1 Group], treated with radical prostatectomy as well as accompanied with amplified pelvic lymphadenectomy, who subsequently presented metastatic lesions to the abdominal wall diagnosed with PET/CT Gallium 68-PMSA technique and treated with abdominal metastasectomy with adequate short term results.

  20. Iodine-131 imaging using 284 keV photons with a small animal CZT-SPECT system dedicated to low-medium-energy photon detection.

    Science.gov (United States)

    Kojima, Akihiro; Gotoh, Kumiko; Shimamoto, Masako; Hasegawa, Koki; Okada, Seiji

    2016-02-01

    Iodine-131 is widely used for radionuclide therapy because of its β-particle and for diagnostic imaging employing its principal gamma ray. Since that principal gamma ray has the relatively high energy of 364 keV, small animal single-photon emission computed tomography (SPECT) imaging systems may be required to possess the ability to image such higher energy photons. The aim of this study was to investigate the possibility of imaging I-131 using its 284 keV photons instead of its 364 keV photons in a small animal SPECT imaging system dedicated to the detection of low-medium-energy photons (below 300 keV). The imaging system used was a commercially available preclinical SPECT instrument with CZT detectors that was equipped with multi-pinhole collimators and was accompanied by a CT imager. An energy window for I-131 imaging was set to a photopeak of 284 keV with a low abundance compared with 364 keV photons. Small line sources and two mice, one of each of two types, that were injected with NaI-131 were scanned. Although higher counts occurred at the peripheral region of the reconstructed images due to the collimator penetration by the 364 keV photons, the shape of the small line sources could be well visualized. The measured spatial resolution was relatively poor (~1.9 mm for full width at half maximum and ~3.9 mm for full width at tenth maximum). However, a good linear correlation between SPECT values and the level of I-131 radioactivity was observed. Furthermore, the uptake of NaI-131 to the thyroid gland for the two mice was clearly identified in the 3D-SPECT image fused with the X-ray CT image. We conclude that the use of an energy window set on the photopeak of 284 keV and the multi-pinhole collimator may permit I-131 imaging for a preclinical CZT-SPECT system that does not have the ability to acquire images using the 364 keV photons.

  1. Dobutamine stress tetrofosmin SPECT. Evaluation of short rest-stress protocol and head to head comparison with MIBI in detection of coronary artery disease

    International Nuclear Information System (INIS)

    Turgut, B.; Unlu, M.; Cengel, A.

    2005-01-01

    The purpose of the present study was to evaluate the feasibility and diagnostic accuracy of same day short rest-dobutamine stress Tetrofosmin (TF) SPECT imaging protocol and to compare TF SPECT results with methoxyisobutyl isonitrile (MIBI) SPECT in the same subjects who were unable to perform treadmill exercise or were unsuitable for pharmacological vasodilator stress. The study group consisted of 19 patients (2 female and 17 male, with a mean age of 53.8±7.9 yrs) in whom coronary artery disease (CAD) had been proven or excluded at coronary angiography (CA). MIBI SPECT imaging was performed first. TF SPECT images were obtained one week after MIBI imaging. Immediately after the rest SPECT imaging in both of the MIBI and TF studies, patients underwent dobutamine stress tests. Rest-stress radiotracer doses and dobutamine doses were the same for both TF and MIBI studies. While 60 min waiting periods were applied for MIBI study, only 30 min waiting periods were applied for TF study after the rest and stress injections. Images were evaluated by visual and quantitative analysis. Dobutamine stress parameters were similar for both studies. Although in TF study, the time between radiopharmaceutical injection and imaging was shorter than in MIBI study, there was no significant difference between heart-to-liver (H/Li) and heart-to-lung (H/Lu) ratios. According to CA results, diagnostic accuracy was similar for TF and MIBI. While sensitivity, specificity and accuracy for TF study were calculated as 82%, 84% and 82%, respectively, the corresponding values for MIBI were 82%, 88% and 84%, respectively. This clinical study has shown comparable diagnostic performance for the detection of CAD between MIBI and TF. Good correlation was found between segmental analysis for both studies. MIBI and TF showed similar perfusion defects and good segmental correlation during dobutamine stress with the same quality images. Both radiopharmaceuticals may be acceptable with this imaging protocol

  2. Gallium imaging of esophageal carcinoma: Increased sensitivity with lateral views of the thorax

    International Nuclear Information System (INIS)

    Sostre, S.; Romero, I.; Rivera, J.V.; Baez, L.; Cintron, E.

    1990-01-01

    Ga-67 imaging has not been very successful in the detection of esophageal carcinoma. In most reports, sensitivity for the primary tumor ranged from 25-61%, but imaging had been done only in anterior and posterior (A-P) projections. We performed gallium scans in 30 patients with esophageal carcinoma, adding lateral views to the routine A-P projections, to study the effect of lateral views on tumor detection. The A-P views detected only 57% of the tumors while the right lateral visualized 89%, and the left lateral detected 100%. Some lesions may be hidden by the sternum and the spine in the routine A-P views. Previous disappointments with Ga-67 imaging of esophageal carcinoma were probably due to this technical factor. Being gallium-avid, esophageal tumors deserve further studies with this agent to determine the role of Ga-67 imaging in this condition. These studies should be performed with multiple views of the thorax or, better yet, with SPECT imaging of the chest, to circumvent the problem of sternum and spine interference

  3. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    Directory of Open Access Journals (Sweden)

    Paulo Henrique Silva Monteiro

    2017-10-01

    Full Text Available Abstract Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs in systemic granulomatous infections in comparison with gallium-67 (67Ga citrate scintigraphy. Materials and Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99mTc-EDDA-HYNIC-TOC, and 21 after injection of 111In-DTPA-octreotide. All patients also underwent 67Ga citrate imaging, except for one patient who died before the 67Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67Ga uptake in 11 of the 20 patients with positive images and similar to 67Ga uptake in the other 9 patients. The only patient who did not undergo 67Ga scintigraphy underwent 99mTc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with 99mTc-EDDA-HYNIC-TOC or 111In-DTPA-octreotide seems to be a good alternative to 67Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  4. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    International Nuclear Information System (INIS)

    Monteiro, Paulo Henrique Silva; Souza, Thiago Ferreira de; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Lima, Mariana da Cunha Lopes de; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. Materials And Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. (author)

  5. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Paulo Henrique Silva; Souza, Thiago Ferreira de; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Lima, Mariana da Cunha Lopes de; Santos, Allan Oliveira; Ramos, Celso Darío, E-mail: paulohsm42@gmail.com [Universidade de Campinas (UNICAMP), SP (Brazil). Escola de Medicina; Mengatti Jair [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-11-15

    Objective: To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ({sup 67}Ga) citrate scintigraphy. Materials And Methods: We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of {sup 99m}Tc-EDDA-HYNIC-TOC, and 21 after injection of {sup 111}In-DTPA-octreotide. All patients also underwent {sup 67}Ga citrate imaging, except for one patient who died before the {sup 67}Ga was available. Results: In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by {sup 67}Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than {sup 67}Ga uptake in 11 of the 20 patients with positive images and similar to {sup 67}Ga uptake in the other 9 patients. The only patient who did not undergo {sup 67}Ga scintigraphy underwent {sup 99m}Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion: SPECT/CT with {sup 99m}Tc-EDDA-HYNIC-TOC or {sup 111}In-DTPA-octreotide seems to be a good alternative to {sup 67}Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. (author)

  6. Improved detection of sentinel lymph nodes in SPECT/CT images acquired using a low- to medium-energy general-purpose collimator.

    Science.gov (United States)

    Yoneyama, Hiroto; Tsushima, Hiroyuki; Kobayashi, Masato; Onoguchi, Masahisa; Nakajima, Kenichi; Kinuya, Seigo

    2014-01-01

    The use of the low-energy high-resolution (LEHR) collimator for lymphoscintigraphy causes the appearance of star-shaped artifacts at injection sites. The aim of this study was to confirm whether the lower resolution of the low- to medium-energy general-purpose (LMEGP) collimator is compensated by decrease in the degree of septal penetration and the reduction in star-shaped artifacts. A total of 106 female patients with breast cancer, diagnosed by biopsy, were enrolled in this study. Tc phytate (37 MBq, 1 mCi) was injected around the tumor, and planar and SPECT/CT images were obtained after 3 to 4 hours. When sentinel lymph nodes (SLNs) could not be identified from planar and SPECT/CT images by using the LEHR collimator, we repeated the study with the LMEGP collimator. Planar imaging performed using the LEHR and LEHR + LMEGP collimators positively identified SLNs in 96.2% (102/106) and 99.1% (105/106) of the patients, respectively. Using combination of planar and SPECT/CT imaging with the LEHR and LEHR + LMEGP collimators, SLNs were positively identified in 97.2% (103/106) and 100% (106/106) of the patients, respectively. The LMEGP collimator provided better results than the LEHR collimator because of the lower degree of septal penetration. The use of the LMEGP collimator improved SLN detection.

  7. Reduced CBF recovery detected by longitudinal 3D-SSP SPECT analyses predicts outcome of postoperative patients after subarachnoid haemorrhage.

    Science.gov (United States)

    Mutoh, Tatsushi; Totsune, Tomoko; Takenaka, Shunsuke; Tatewaki, Yasuko; Nakagawa, Manabu; Suarez, Jose I; Taki, Yasuyuki; Ishikawa, Tatsuya

    2018-02-01

    The aim of this study was to evaluate the impact of cerebral blood flow (CBF) recovery obtained from brain single-photon emission computed tomography (SPECT) images on postoperative outcome after aneurysmal subarachnoid haemorrhage (SAH). Twenty-nine patients who had undergone surgical clipping for ruptured anterior communicating artery aneurysms were analyzed prospectively. Routine measurements of CBF were performed using technetium-99 m hexamethyl propyleneamine oxine SPECT on days 4 and 14 after SAH. Regional voxel data analyzed by three dimensional stereotactic surface projection (3D-SSP) were compared between patients and age-matched normal database (NDB). In 3D-SSP analysis of all patients, cortical hypoperfusion around the surgical site in bilateral frontal lobes was evident on day 4 (P SSP SPECT image analyses can be a potential predictor of poor prognosis in postoperative patients after SAH. © 2017 John Wiley & Sons Australia, Ltd.

  8. Detection of low-grade prosthetic joint infections using 99mTc-antigranulocyte SPECT/CT: initial clinical results

    International Nuclear Information System (INIS)

    Graute, Vera; Lehner, Sebastian; Haug, Alexander; Bartenstein, Peter; Hacker, Marcus; Feist, Markus; Mueller, Peter Ernst

    2010-01-01

    Low-grade joint infections are characterized by infiltration of granulocytes, which mediate aspects of inflammatory changes. We evaluated retrospectively the contribution of SPECT/CT as an addition to planar scintigraphy with 99m Tc-labelled antigranulocyte antibodies for diagnosing and localizing low-grade joint infections. Planar scintigraphy using 99m Tc-labelled antigranulocyte BW 250/183 antibodies was performed in 31 patients with suspected joint infections at 5 min, 5 h and 24 h after injection, with additional SPECT/CT performed 6 h after injection. With reference to gold standard clinical data, we assessed the diagnostic sensitivity of scintigraphy alone and in conjunction with SPECT/CT. Joint infections were diagnosed clinically in 9 of the 31 patients (1 hip and 8 knee prostheses). Planar scintigraphy revealed 6 true-positives, 13 true-negatives, 9 false-positives and 3 false-negative results, indicating sensitivity, specificity, positive and negative predictive values of, respectively, 0.66, 0.60, 0.4 and 0.81. With the addition of SPECT images, corresponding sensitivity, specificity, positive and negative predictive values increased to 0.89, 0.45, 0.40 and 0.91. Implementation of fused SPECT/CT led to a further increase to 0.89, 0.73, 0.57 and 0.94. Relative to planar scintigraphy, SPECT with and without CT substantially improved the utility of imaging with 99m Tc-labelled antigranulocyte antibodies for diagnosis and localization of suspected joint infections. Optimal accuracy was obtained through image fusion, which permitted anatomical allocation of foci of pathological tracer accumulation as well as providing information on the extent of the infection. This imaging method seems suited for selection of patients requiring surgical therapy. (orig.)

  9. Clinical evaluation of SPECT in cerebrovascular disease

    International Nuclear Information System (INIS)

    Oshibuchi, Masao; Satoh, Mitsutaka; Kanda, Tetsuro; Nishi, Fumiaki; Yamane, Kanji; Fujimatsu, Masahiko; Edamitsu, Satoshi; Anno, Yasuro; Ohtake, Hisashi.

    1989-01-01

    In 131 patients with cerebrovascular disease, regional cerebral blood flow were determined by 123 I-IMP (N-isopropyl ( 123 I)-iodoamphetamine) or 99m Tc-HM-PAO ( 99m Tc (d, 1)-hexamethyl propyleneamine oxime) SPECT and findings were compared with those of X-CT or MRI. The perfusion deficit detected by SPECT was larger than the deficit by X-CT or MRI in every case. The perfusion deficit area was more clearly demonstrated by SPECT than by X-CT or MRI in patients with acute cerebral infarction. The hypoperfusion area determined by 123 I-IMP SPECT was wider than that by 99m Tc-HM-PAO SPECT. The crossed cerebellar diaschisis was observed in 56 out of 131 cases (43%). The results of operation were quantitatively evaluated by 123 I-IMP SPECT in 25 patients. (author)

  10. Comparison of {sup 131}I whole-body imaging, {sup 131}I SPECT/CT, and {sup 18}F-FDG PET/CT in the detection of metastatic thyroid cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jong-Ryool; Chong, Ari; Kim, Jahae; Kang, Sae-Ryung; Song, Ho-Chun; Bom, Hee-Seung [Chonnam National University Hospital, Department of Nuclear Medicine, Clinical Medicine Research Center, Gwangju (Korea, Republic of); Byun, Byung-Hyun; Hong, Sun-Pyo; Yoo, Su-Woong [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Clinical Medicine Research Center, Hwasun, Jeonnam (Korea, Republic of); Kim, Dong-Yeon [Dongguk University, Department of Chemistry, Seoul (Korea, Republic of); Chonnam National University Hospital, Department of Nuclear Medicine, Clinical Medicine Research Center, Gwangju (Korea, Republic of); Min, Jung-Joon [Chonnam National University Hwasun Hospital, Department of Nuclear Medicine, Clinical Medicine Research Center, Hwasun, Jeonnam (Korea, Republic of); Center for Biomedical Human Resources at Chonnam National University, Brain Korea 21 Project, Gwangju (Korea, Republic of)

    2011-08-15

    The aim of this study was to compare {sup 131}I whole-body scintigraphy (WBS), WBS with {sup 131}I single photon emission computed tomography/computed tomography (SPECT/CT), and {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT in the detection of distant metastases of differentiated thyroid cancer (DTC). A total of 140 patients with 258 foci of suspected distant metastases were evaluated. {sup 131}I WBS, {sup 131}I SPECT/CT, and {sup 18}F-FDG PET/CT images were interpreted separately. The final diagnosis was obtained from histopathologic study, serum thyroglobulin level, other imaging modalities, and/or clinical follow-up. Of the 140 patients with 258 foci, 46 patients with 166 foci were diagnosed as positive for distant metastasis. The sensitivity, specificity, and diagnostic accuracy of each imaging modality were 65, 55, and 59%, respectively, for {sup 131}I WBS; 65, 95, and 85% for {sup 131}I SPECT/CT, respectively; and 61, 98, and 86%, respectively, for {sup 18}F-FDG PET/CT in patient-based analyses. Lesion-based analyses demonstrated that both SPECT/CT and PET/CT were superior to WBS (p<0.001) in all patient groups. SPECT/CT was superior to WBS and PET/CT (p<0.001) in patients who received a single challenge of radioiodine therapy, whereas PET/CT was superior to WBS (p=0.005) and SPECT/CT (p=0.013) in patients who received multiple challenges. Both SPECT/CT and PET/CT demonstrated high diagnostic performance in detecting metastatic thyroid cancer. SPECT/CT was highly accurate in patients who underwent a single challenge of radioiodine therapy. In contrast, {sup 18}F-FDG PET/CT presented the highest diagnostic performance in patients who underwent multiple challenges of radioiodine therapy. (orig.)

  11. 99m Tc-MIP-1404-SPECT/CT for the detection of PSMA-positive lesions in 225 patients with biochemical recurrence of prostate cancer.

    Science.gov (United States)

    Schmidkonz, Christian; Hollweg, Claudia; Beck, Michael; Reinfelder, Julia; Goetz, Theresa I; Sanders, James C; Schmidt, Daniela; Prante, Olaf; Bäuerle, Tobias; Cavallaro, Alexander; Uder, Michael; Wullich, Bernd; Goebell, Peter; Kuwert, Torsten; Ritt, Philipp

    2018-01-01

    99m Tc-MIP-1404 (Progenics Pharmaceuticals, Inc., New York, NY) is a novel, SPECT-compatible 99m Tc-labeled PSMA inhibitor for the detection of prostate cancer. We present results of its clinical use in a cohort of 225 men with histologically confirmed prostate cancer referred for workup of biochemical relapse. From April 2013 to April 2017, 99m Tc-MIP1404-scintigraphy was performed in 225 patients for workup of PSA biochemical relapse of prostate cancer. Whole-body planar and SPECT/CT images of the lower abdomen and thorax were obtained 3-4 h p.i. of 710 ± 64 MBq 99m Tc-MIP-1404. Images were visually analyzed for presence and location of abnormal uptake. In addition, quantitative analysis of the SPECT/CT data was carried out on a subset of 125 patients. Follow-up reports of subsequent therapeutic interventions were available for 59% (139) of all patients. Tracer-positive lesions were detected in 77% (174/225) of all patients. Detections occurred at the area of local recurrence in the prostate in 25% of patients (or a total of 56), with metastases in lymph nodes in 47% (105), bone in 27% (60), lung in 5% (12), and other locations in 2% (4) of patients. Detection rates were 90% at PSA levels ≥2 ng/mL and 54% below that threshold. Lesional SUVmax values were, on average, 32.2 ± 29.6 (0.8-142.2), and tumor-to-normal ratios 146.6 ± 160.5 (1.9-1482.4). The PSA level correlated significantly with total uptake of MIP-1404 in tumors (P Tc-MIP-1404-imaging and other information, an interdisciplinary tumor board review recommended changes to treatment plans in 74% (104/139) of those patients for whom the necessary documentation was available. SPECT/CT with 99m Tc-labeled MIP-1404 has a high probability in detecting PSMA-positive lesions in patients with elevated PSA. Statistical analysis disclosed significant relationship between quantitative 99m Tc-MIP-1404 uptake, PSA level, and Gleason score. © 2017 Wiley Periodicals, Inc.

  12. Septic arthritis of a lumbar facet joint: Detection with bone SPECT imaging

    International Nuclear Information System (INIS)

    Swayne, L.C.; Dorsky, S.; Caruana, V.; Kaplan, I.L.

    1989-01-01

    We present a rare case of septic arthritis of a lumbar facet joint with an associated epidural abscess resulting from Staphylococcus aureus. The infection was initially detected with planar bone scintigraphy and precisely localized with single photon emission computed tomography bone scintigraphy, despite an initially negative radiologic evaluation that included radiographs of the lumbar spine, lumbar myelography, and a postmyelography x-ray computed tomography scan. In the appropriate clinical setting, a bone scan demonstrating unilateral increased activity within the spine should raise the suspicion of inflammatory involvement of the posterior elements

  13. Psoas abscess localization by gallium scan in aplastic anemia

    International Nuclear Information System (INIS)

    Oster, M.W.; Gelrud, L.G.; Lotz, M.J.; Herzig, G.P.; Johnston, G.S.

    1975-01-01

    Gallium 67 scanning is an effective method of detecting inflammatory lesions, especially abscesses. A 10-year-old boy with aplastic anemia and severe leukopenia and granulocytopenia had a psoas abscess diagnosed by gallium scan. The patient died with Candida sepsis 18 days after bone marrow transplantation. At autopsy, a chronic psoas abscess with Candida was found. The gallium scan offers a clinically effective and noninvasive means of evaluating suspected infection in the granulocytopenia patient. (U.S.)

  14. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Padua, Rodrigo Donizete Santana de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Div. de Cardiologia]. E-mail: rodrigo_dsp@hcrp.fmrp.usp.br; Oliveira, Lucas Ferrari de [Universidade Federal de Pelotas (UFPel), RS (Brazil). Inst. de Fisica e Matematica. Dept. de Tecnologia da Informacao; Marques, Paulo Mazzoncini de Azevedo [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Groote, Jean-Jacques Georges Soares de [Instituto de Ensino Superior COC, Ribeirao Preto, SP (Brazil). Lab. of Artifical Intelligence and Applications; Castro, Adelson Antonio de [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina; Ana, Lauro Wichert [Universidade de Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Centro de Ciencias das Imagens e Fisica Medica; Simoes, Marcus Vinicius [Universidade de Sao Paulo (USP), Ribeirao Preto, SP, (Brazil). Faculdade de Medicina. Divisao de Cardiologia

    2008-11-15

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  15. Aid in the detection of myocardial perfusion abnormality utilizing SPECT atlas and images registration: preliminary results

    International Nuclear Information System (INIS)

    Padua, Rodrigo Donizete Santana de; Oliveira, Lucas Ferrari de; Marques, Paulo Mazzoncini de Azevedo; Groote, Jean-Jacques Georges Soares de; Castro, Adelson Antonio de; Ana, Lauro Wichert; Simoes, Marcus Vinicius

    2008-01-01

    To develop an atlas of myocardial perfusion scintigraphy and evaluating its applicability in computer-aided detection of myocardial perfusion defects in patients with ischemic heart disease. The atlas was created with rest-stress myocardial perfusion scintigraphic images of 20 patients of both genders with low probability of coronary artery disease and considered as normal by two experienced observers. Techniques of image registration and mathematical operations on images were utilized for obtaining template images depicting mean myocardial uptake and standard deviation for each gender and physiological condition. Myocardial perfusion scintigraphy images of one male and one female patient were aligned with the corresponding atlas template image, and voxels with myocardial uptake rates two standard deviations below the mean voxel value of the respective region in the atlas template image were highlighted on the tomographic sections and confirmed as perfusion defects by both observe. The present study demonstrated the creation of an atlas of myocardial perfusion scintigraphy with promising results of this tool as an aid in the detection of myocardial perfusion defects. However, further prospective validation with a more representative sample is recommended. (author)

  16. Investigations in gallium removal

    Energy Technology Data Exchange (ETDEWEB)

    Philip, C.V.; Pitt, W.W. [Texas A and M Univ., College Station, TX (United States); Beard, C.A. [Amarillo National Resource Center for Plutonium, TX (United States)

    1997-11-01

    Gallium present in weapons plutonium must be removed before it can be used for the production of mixed-oxide (MOX) nuclear reactor fuel. The main goal of the preliminary studies conducted at Texas A and M University was to assist in the development of a thermal process to remove gallium from a gallium oxide/plutonium oxide matrix. This effort is being conducted in close consultation with the Los Alamos National Laboratory (LANL) personnel involved in the development of this process for the US Department of Energy (DOE). Simple experiments were performed on gallium oxide, and cerium-oxide/gallium-oxide mixtures, heated to temperatures ranging from 700--900 C in a reducing environment, and a method for collecting the gallium vapors under these conditions was demonstrated.

  17. Investigations in gallium removal

    International Nuclear Information System (INIS)

    Philip, C.V.; Pitt, W.W.; Beard, C.A.

    1997-11-01

    Gallium present in weapons plutonium must be removed before it can be used for the production of mixed-oxide (MOX) nuclear reactor fuel. The main goal of the preliminary studies conducted at Texas A and M University was to assist in the development of a thermal process to remove gallium from a gallium oxide/plutonium oxide matrix. This effort is being conducted in close consultation with the Los Alamos National Laboratory (LANL) personnel involved in the development of this process for the US Department of Energy (DOE). Simple experiments were performed on gallium oxide, and cerium-oxide/gallium-oxide mixtures, heated to temperatures ranging from 700--900 C in a reducing environment, and a method for collecting the gallium vapors under these conditions was demonstrated

  18. Mnemonic activation by SPECT

    International Nuclear Information System (INIS)

    Migneco, O.; Darcourt, J.; Benoit, M; Malandain, G.; Thirion, J.P.; Robert, Ph.; Vidal, R.; Desvignes, Ph.; Benoliel, J.; Ayache, N.; Bussiere, F.

    1997-01-01

    Data of literature show that SPECT is able to detect cerebral activations induced by sensory-motor stimuli. The facts are not clearly established in what concerns the cognitive activations the amplitude of which is lower. We have studied an activation paradigm such as the Grober and Bruschke test which implies the long term explicit memory. It comprises a visual presentation of words followed by their indexed recall. By using a two-day protocol, 2 SPECTs were achieved in 4 healthy right-handed voluntaries as follows: one of activation (A) and one of control (B). The fifth subject benefited by a SPECT B and of an MRI. The injection for the examination A has been done during the indexed recall stage and for the examination B at the moment when the patient repeated several times the same 3 words. The SPECT data were collected 1 hour after the injection of 370 MBq of ECD making use of a 3-head camera equipped with UHR fan collimators and ending by a LMH on the reconstructed images of 8 mm. The MRI has been achieved by means of a Signa 1.5 Tesla magnet. The SPECT A and B of the subjects 1 to 4 were matched elastically to that of the subject 5 and that of the subject 5 was rigidly matched on its MRI. In this way the individual activation cards of the 4 subjects could be averaged and superimposed on the MRI of the 5. subject. One observes an internal temporal activation (maximal activation of left tonsil, +25% and right uncus, +23%) and a right cingulum activation (maximal activation, +25%), in agreement with the neuro-physiological data. The elastic matching makes possible the inter-subject averaging, what increases the signal-to-noise ratio of activation. The inter-modality rigid matching facilitates the anatomical localisation of the activation site. With these adapted tools, the cognitive activation is thus possible by SPECT and opens perspectives for early diagnosis of neurological troubles, namely of Alzheimer's disease

  19. Blood lipid levels and SPECT of myocardium perfusion to type 2 asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Pena Quian, Yamile; Fernandez-Britto Rodriguez, Jose; Coca Perez, Marco A; Batista Cuellar, Juan F; Rochela Vazquez, Luis Manuel

    2006-01-01

    SPECT, coronary angiography and laboratories test were performed on 31 asymptomatic type 2 diabetes patients, in order to determine the relationship among the lipid levels in blood and the results of the SPECT. Patients were classified in two groups (positive SPECT or negative SPECT). Simple descriptive statistics were calculated for all variables in both groups. Positive SPECT was detected in 35,5% of the patients and negative SPECT in 64,5%.The coronary angiography and SPECT showed good correlation. Low values of HDLc showed significant association with the positive results of the SPECT. The logistical regression showed an increment of the capacity to predict a positive SPECT if the values of HDLc are used. Conclusion: The present investigation demonstrated a significant association among the low levels of HDLc in blood and the positive results of the SPECT. The low values of HDLc could predict the possibility of a positive SPECT in asymptomatic diabetic type 2 patients (au)

  20. An Assessment of a Low-Cost Visual Tracking System (VTS) to Detect and Compensate for Patient Motion During SPECT

    Science.gov (United States)

    McNamara, Joseph E.; Bruyant, Philippe; Johnson, Karen; Feng, Bing; Lehovich, Andre; Gu, Songxiang; Gennert, Michael A.; King, Michael A.

    2008-06-01

    Patient motion is inevitable in SPECT and PET due to the lengthy period of time patients are imaged and patient motion can degrade diagnostic accuracy. The goal of our studies is to perfect a methodology for tracking and correcting patient motion when it occurs. In this paper we report on enhancements to the calibration, camera stability, accuracy of motion tracking, and temporal synchronization of a low-cost visual tracking system (VTS) we are developing. The purpose of the VTS is to track the motion of retro-reflective markers on stretchy bands wrapped about the chest and abdomen of patients. We have improved the accuracy of 3D spatial calibration by using a MATLAB optical camera calibration package with a planar calibration pattern. This allowed us to determine the intrinsic and extrinsic parameters for stereo-imaging with our CCD cameras. Locations in the VTS coordinate system are transformed to the SPECT coordinate system by a VTS/SPECT mapping using a phantom of 7 retro-reflective spheres each filled with a drop of Tc99m. We switched from pan, tilt and zoom (PTZ) network cameras to fixed network cameras to reduce the amount of camera drift. The improved stability was verified by tracking the positions of fixed retro-reflective markers on a wall. The ability of our VTS to track movement, on average, with sub-millimeter and sub-degree accuracy was established with the 7-sphere phantom for 1 cm vertical and axial steps as well as for an arbitrary rotation and translation. The difference in the time of optical image acquisition as decoded from the image headers relative to synchronization signals sent to the SPECT system was used to establish temporal synchrony between optical and list-mode SPECT acquisition. Two experiments showed better than 100 ms agreement between VTS and SPECT observed motion for three axial translations. We were able to track 3 reflective markers on an anthropomorphic phantom with a precision that allowed us to correct motion such that no

  1. LROC Investigation of Three Strategies for Reducing the Impact of Respiratory Motion on the Detection of Solitary Pulmonary Nodules in SPECT

    Science.gov (United States)

    Smyczynski, Mark S.; Gifford, Howard C.; Dey, Joyoni; Lehovich, Andre; McNamara, Joseph E.; Segars, W. Paul; King, Michael A.

    2016-02-01

    The objective of this investigation was to determine the effectiveness of three motion reducing strategies in diminishing the degrading impact of respiratory motion on the detection of small solitary pulmonary nodules (SPNs) in single-photon emission computed tomographic (SPECT) imaging in comparison to a standard clinical acquisition and the ideal case of imaging in the absence of respiratory motion. To do this nonuniform rational B-spline cardiac-torso (NCAT) phantoms based on human-volunteer CT studies were generated spanning the respiratory cycle for a normal background distribution of Tc-99 m NeoTect. Similarly, spherical phantoms of 1.0-cm diameter were generated to model small SPN for each of the 150 uniquely located sites within the lungs whose respiratory motion was based on the motion of normal structures in the volunteer CT studies. The SIMIND Monte Carlo program was used to produce SPECT projection data from these. Normal and single-lesion containing SPECT projection sets with a clinically realistic Poisson noise level were created for the cases of 1) the end-expiration (EE) frame with all counts, 2) respiration-averaged motion with all counts, 3) one fourth of the 32 frames centered around EE (Quarter Binning), 4) one half of the 32 frames centered around EE (Half Binning), and 5) eight temporally binned frames spanning the respiratory cycle. Each of the sets of combined projection data were reconstructed with RBI-EM with system spatial-resolution compensation (RC). Based on the known motion for each of the 150 different lesions, the reconstructed volumes of respiratory bins were shifted so as to superimpose the locations of the SPN onto that in the first bin (Reconstruct and Shift). Five human observers performed localization receiver operating characteristics (LROC) studies of SPN detection. The observer results were analyzed for statistical significance differences in SPN detection accuracy among the three correction strategies, the standard

  2. Age-related changes in brain perfusion of normal subjects detected by 99mTc-HMPAO SPECT

    International Nuclear Information System (INIS)

    Krausz, Y.; Karger, H.; Chisin, R.; Bonne, O.; Gorfine, M.; Lerer, B.

    1998-01-01

    Previous functional imaging data generally show impairment in global cerebral blood flow (CBF) with age. Conflicting data, however, concerning age-related changes in regional CBF (rCBF) have been reported. We examined the relative rCBF in a sample of healthy subjects of various ages, to define and localize any age-related CBF reduction. Twenty-seven healthy subjects (17 male, 10 female; mean age 49 ± 15, range 26-71, median 47 years) were studied by 99m Tc-HMPAO brain SPECT. The younger age group consisted of subjects below, the older group above 47 years of age, respectively. Analysis was performed by applying three preformed templates, each containing delineated regions of interest (ROIs), to three transaxial brain slices at approximately 4, 6, and 7 cm above the orbitomeatal line (OML). The average number of counts for each ROI was normalized to mean uptake of the cerebellum and of the whole brain slice. Globally, 99m Tc-HMPAO uptake ratio normalized to cerebellum was significantly decreased in older subjects, affecting both hemispheres. A slight left-to-right asymmetry was observed in HMPAO uptake of the whole study group. It did not, however, change with age. Regionally, both cortical and subcortical structures of older subjects were involved: uptake ratio to cerebellum was significantly lower (after correction for multiple testing) in the left basal ganglia and in the left superior temporal, right frontal and bilateral occipital cortices at 4 cm above the OML. At 6 cm above the OML, reduced uptake ratios were identified in the left frontal and bilateral parietal areas. At 7 cm, reduced uptake was detected in the right frontal and left occipital cortices. Most of these differences were reduced when uptake was normalized to whole slice, whereas an increase in uptake ratios was observed in the cingulate cortex of the elderly. An inverse correlation between age and HMPAO uptake ratios normalized to cerebellum was observed in a number of brain regions. These

  3. Comparison of exercise and pharmacological stress gated SPECT in detecting transient left ventricular dysfunction

    International Nuclear Information System (INIS)

    Demir, Hakan; Tan, Yusuf Z.; Isgoren, Serkan; Gorur, Gozde D.; Kozdag, Guliz; Ural, Ertan; Berk, Fatma

    2008-01-01

    119 (39%) and 12 of 101 (12%) subjects, in patients with and without ischemia, respectively (P<0.0001). On the other hand, in group II, TLVD was detected in 35 of 104 (34%) and 8 of 115 (7%) patients with and without ischemia, respectively (P<0.0001). And also, we found significant good correlations between TID ratios and DLVEF values in four subgroups (r=-0.55, r=-0.62, r=-0.59, and r=-0.41; for groups IA, IB, IIA, and IIB, respectively, P<0.0001 for all). Dipyridamole is believed to be less likely than exercise to induce ischemia. However, in this study, TLVD after stress was observed following not only exercise but also pharmacological stress, consistent with ischemia. (author)

  4. Diagnostic sensitivity of Tc-99m HYNIC PSMA SPECT/CT in prostate carcinoma: A comparative analysis with Ga-68 PSMA PET/CT.

    Science.gov (United States)

    Lawal, Ismaheel O; Ankrah, Alfred O; Mokgoro, Neo P; Vorster, Mariza; Maes, Alex; Sathekge, Mike M

    2017-08-01

    Emerging data from published studies are demonstrating the superiority of Ga-68 PSMA PET/CT imaging in prostate cancer. However, the low yield of the Ge-68/Ga-68 from which Gallium-68 is obtained and fewer installed PET/CT systems compared to the SPECT imaging systems may limit its availability. We, therefore, evaluated in a head-to-head comparison, the diagnostic sensitivity of Ga-68 PSMA PET/CT and Tc-99m PSMA SPECT/CT in patients with prostate cancer. A total of 14 patients with histologically confirmed prostate cancer were prospectively recruited to undergo Ga-68 PSMA PET/CT and Tc-99m HYNIC PSMA SPECT/CT. The mean age of patients was 67.21 ± 8.15 years and the median PSA level was 45.18 ng/mL (range = 1.51-687 ng/mL). SUVmax of all lesions and the size of lymph nodes with PSMA avidity on Ga-68 PSMA PET/CT were determined. Proportions of these lesions detected on Tc-99m HYNIC PSMA SPECT/CT read independent of PET/CT findings were determined. A total of 46 lesions were seen on Ga-68 PSMA PET/CT localized to the prostate (n = 10), lymph nodes (n = 24), and bones (n = 12). Of these, Tc-99m HYNIC PSMA SPECT/CT detected 36 lesions: Prostate = 10/10 (100%), lymph nodes = 15/24 (62.5%), and bones = 11/12 (91.7%) with an overall sensitivity of 78.3%. Lesions detected on Tc-99m HYNIC PSMA SPECT/CT were bigger in size (P Tc-99m HYNIC PSMA SPECT/CT. In a univariate analysis, Lymph node size (P = 0.033) and the SUVmax of all lesions (P = 0.007) were significant predictors of lesion detection on Tc-99m HYNIC PSMA SPECT/CT. Tc-99m HYNIC PSMA may be a useful in imaging of prostate cancer although with a lower sensitivity for lesion detection compared to Ga-68 PSMA PET/CT. Its use is recommended when Ga-68 PSMA is not readily available, in planning radio-guided surgery or the patient is being considered for radio-ligand therapy with Lu-177 PSMA. It performs poorly in detecting small-sized lesions hence its use is not recommended

  5. Ventilation abnormalities in obstructive airways disorder. Detection with pulmonary dynamic densitometry by means of spinal CT versus dynamic Xe-133 SPECT

    International Nuclear Information System (INIS)

    Suga, Kazuyoshi; Nishigauchi, Kazuya; Kume, Norihiko; Takana, Katsuyuki; Koike, Shinji; Shimizu, Kensaku; Matsunaga, Naofumi

    1999-01-01

    The usefulness of pulmonary dynamic densitometry (PDD) acquired by spiral computed tomography (CT) to detect ventilation abnormalities in obstructive airway disorders was evaluated in comparison with dynamic xenon-133 (Xe-133) SPECT. Eight-second, continuous spiral CT scan was performed over 2-3 respiratory cycles in six healthy volunteers, 19 patients with airways disorder, and six patients with restrictive lung disease. The data set were reconstructed as 36 one-second temporally overlapping images at 0.2-second intervals, and regional PDD curves were displayed. Regional ventilation was assessed by Xe-133 clearance-time on Xe-133 SPECT. Normal lungs showed smooth, sinusoidal PDD curves with maximal amplitude in lung attenuation change (MALAC) of 54.9+24.5 HU; whereas, obstructive airways disorders with prolonged Xe-133 clearance showed significantly diminished MALAC (31.6+20.1 HU, P<0.0001), accompanied by irregularity, asynchronous phase, and deterioration of normal ventral-to-dorsal gradients in MALAC and lung attenuation. Restrictive diseases without prolonged Xe-133 clearance did not show statistically significant reduction in MALAC. In total 251 lung regions, regional MALAC correlated inversely with Xe-133 clearance-time (r=842). PDD acquired by spiral CT is acceptable for detecting ventilation abnormalities in obstructive airways disorder. (author)

  6. Automatic method detection of artifacts for control of tomographic uniformity on SPECT; Metodo automatico de dteccion de artefactos para el control de la uniformidad tomografica en SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Reynes Llompart, G.; Puchal, R.

    2013-07-01

    The objective of this work is the find an automatic method for the detection and classification of artifacts produced in tomographic uniformity, extracting the characteristics necessary to apply a classification algorithm using pattern recognition techniques. The method has been trained and validated with synthetic images and tested with real images. (Author)

  7. Tc-99m-HMPAO-Labeled leukocyte SPECT/CT in pediatrics: detecting Candida albicans tricuspid endocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Calais, Jeremie; Edet-Sanson, Agathe; Gaucher, Stephane; Vera, Pierre; Cloirec, Joseph Le [Henri Becquerel Cancer Center and Rouen Univ. Hospital, Rouen (France)

    2015-12-15

    These results led to performing TEE, which showed tricuspid vegetation. Blood cultures were then positive to Candida albicans. Control blood cultures and TEE performed 6 weeks later after adapted antifungal therapy remained negative. In accordance with the results of Erba and al., this case illustrates the usefulness of late thoracic SPECT-CT acquisition of a WBC scan in a patient with high clinical suspicion of endocarditis and identified risk factors but inconclusive echocardiographic findings.

  8. Tc-99m-HMPAO-Labeled leukocyte SPECT/CT in pediatrics: detecting Candida albicans tricuspid endocarditis

    International Nuclear Information System (INIS)

    Calais, Jeremie; Edet-Sanson, Agathe; Gaucher, Stephane; Vera, Pierre; Cloirec, Joseph Le

    2015-01-01

    These results led to performing TEE, which showed tricuspid vegetation. Blood cultures were then positive to Candida albicans. Control blood cultures and TEE performed 6 weeks later after adapted antifungal therapy remained negative. In accordance with the results of Erba and al., this case illustrates the usefulness of late thoracic SPECT-CT acquisition of a WBC scan in a patient with high clinical suspicion of endocarditis and identified risk factors but inconclusive echocardiographic findings

  9. Combined SPECT/CT improves detection of initial bone invasion and determination of resection margins in squamous cell carcinoma of the head and neck compared to conventional imaging modalities

    Energy Technology Data Exchange (ETDEWEB)

    Kolk, A. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Oral and Maxillofacial Surgery, Munich (Germany); Klinikum rechts der Isar, Technische Universitaet Muenchen, Klinik und Poliklinik fuer Mund-Kiefer und Gesichtschirurgie, Muenchen (Germany); Schuster, T. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Institute of Medical Statistics and Epidemiology, Munich (Germany); Chlebowski, A.; Kesting, M.; Bissinger, O.; Weitz, J. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Oral and Maxillofacial Surgery, Munich (Germany); Lange, P. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Diagnostic Radiology, Munich (Germany); Scheidhauer, K.; Schwaiger, M.; Dinges, J. [Technische Universitaet Muenchen, Klinikum rechts der Isar, Department of Nuclear Medicine, Munich (Germany)

    2014-07-15

    revealed bone infiltration in two additional patients (7 %), who both showed discrete cortical bone erosion not visible by MSCT or MRI. There were no false-positive or false-negative findings on SPECT/CT. The quality criteria for detecting bone involvement in HNSCC by SPECT/CT were as follows: sensitivity 100 % (lower 95 % confidence interval limit 80 %), specificity 100 % (75 %), positive predictive value 100 % (80 %) and negative predictive value 100 % (75 %). Corresponding data for MRI were 95 % (76 %), 94 % (73 %), 95 % (76 %) and 94 % (73 %), and for MSCT were 89 % (71 %), 100 % (85 %), 100 % (86 %) and 88 % (69 %). In the retrospective evaluation SPECT showed results similar to SPECT/CT. Hybrid SPECT/CT has a high specificity as it can provide additional information about the existence and local extent of malignant bone infiltration of the mandible. Although the sensitivity of conventional SPECT is similar to that of SPECT/CT, the latter provides a much better delineation of the local tumour-bone contact area. Based on this information, surgical intervention of the rim versus partial resection can be planned and performed more precisely. Patient outcome can be improved by avoiding undertreatment and unnecessary or overextended bone resections. (orig.)

  10. Combined SPECT/CT improves detection of initial bone invasion and determination of resection margins in squamous cell carcinoma of the head and neck compared to conventional imaging modalities

    International Nuclear Information System (INIS)

    Kolk, A.; Schuster, T.; Chlebowski, A.; Kesting, M.; Bissinger, O.; Weitz, J.; Lange, P.; Scheidhauer, K.; Schwaiger, M.; Dinges, J.

    2014-01-01

    bone infiltration in two additional patients (7 %), who both showed discrete cortical bone erosion not visible by MSCT or MRI. There were no false-positive or false-negative findings on SPECT/CT. The quality criteria for detecting bone involvement in HNSCC by SPECT/CT were as follows: sensitivity 100 % (lower 95 % confidence interval limit 80 %), specificity 100 % (75 %), positive predictive value 100 % (80 %) and negative predictive value 100 % (75 %). Corresponding data for MRI were 95 % (76 %), 94 % (73 %), 95 % (76 %) and 94 % (73 %), and for MSCT were 89 % (71 %), 100 % (85 %), 100 % (86 %) and 88 % (69 %). In the retrospective evaluation SPECT showed results similar to SPECT/CT. Hybrid SPECT/CT has a high specificity as it can provide additional information about the existence and local extent of malignant bone infiltration of the mandible. Although the sensitivity of conventional SPECT is similar to that of SPECT/CT, the latter provides a much better delineation of the local tumour-bone contact area. Based on this information, surgical intervention of the rim versus partial resection can be planned and performed more precisely. Patient outcome can be improved by avoiding undertreatment and unnecessary or overextended bone resections. (orig.)

  11. Can perfusion SPECT aid CTPA interpretation?

    International Nuclear Information System (INIS)

    Gradinscak, D. J.; Roach, P.; Bailey, E.; Kueh, S.

    2009-01-01

    Full text:Objective: To determine whether fusion of perfusion SPECT and CTPA improves the diagnostic accuracy of CTPA. Methods: 35 patients with suspected PE who underwent both CTPA and SPECT V/Q within 48 hours were included. Of these, the majority (n=30) had PE as determined by the V/Q SPECT scan and the others (n=5) were negative for PE. The clinical reports of CTPA were reviewed and pulmonary emboli tabulated based on anatomical location. A second radiologist, blinded to the results of the clinical read and the V/Q SPECT scan, reviewed the CTPA with and without perfusion SPECT fusion for assistance. Results: A total 57 PE were reported on the clinical reports and 60 PE identified on the blinded read. Fused CTPA/perfursion SPECT images identified a further 5 PE not identified on the clinical read (8% increase) and 2 PE not identified on the blinded read (3% increase). The additional emboli detected resulted in a change in final diagnosis from PE negative to PE positive in 2 patients (6%) compared with the clinical read and 1 patient (3%) compared with the blinded read without SPECT fusion. Conclusion: Fused CTPA-SPECT perfusion improves the sensitivity of CTPA for the detection of PE in a small number of patients. Fused data may help guide the radiologist to identify sites of PE on CTPA.

  12. Gallium and imaging studies

    International Nuclear Information System (INIS)

    Vogel, H.C.

    1982-01-01

    The indications for the use of 67 Gallium imaging studies of the lungs are discussed. In spite of localization of 67 Ga in a large variety of neoplastic and inflammatory tissues, there is only limited application of the lung study in the differential diagnosis of pulmonary diseases. The chest radiograph will continue to be the principal tool for evaluation of pulmonary diseases. The 67 Ga-citrate scan serves as a study complementary to the chest radiograph, as it indicates the localization, extent and degree of activity of lung disease with greater accuracy than radiography. Gallium-67 scanning may be used in the evaluation of patients with lymphoreticular neoplasms, especially Hodgkin-disease and malignant lymphoma both during initial staging and in evaluation of the response to therapy. The 67 Ga-citrate scan is useful in the pre-operative evaluation of patients with lung cancer. Hilar and mediastinal lymphadenopathy are accurately revealed. The lung study is non-invasive and complementary to mediastinoscopy by showing from which glands a biopsy might be taken. Unsuspected extrathoracic secondaries may be shown up, as well as pulmonary metastases from malignancies elsewhere, although the metastases must be at least 1,5 cm in size. The 67 Ga lung scan is valuable in the evaluation of pulmonary infiltrates of suspicious infective etiology, the differentiation between pulmonary infection and pneumonia in selected cases, follow-up of sarcoid patients on corticosteroid therapy, evaluation of inflammatory activity of idiopathic pulmonary fibrosis and the early detection of neo-plastic or inflammatory diseases before the chest radiograph reveals abnormality, e.g. in diffuse carcinomatosis or Pneumocystis carinii-infection. The sensitivity of tumors to radiation or chemotherapy may be shown

  13. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  14. Detection of misery perfusion in the cerebral hemisphere with chronic unilateral major cerebral artery steno-occlusive disease using crossed cerebellar hypoperfusion: comparison of brain SPECT and PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Yoshiyasu; Ogasawara, Kuniaki; Saito, Hideo; Takahashi, Yoshihiro; Ogasawara, Yasushi; Kobayashi, Masakazu; Ogawa, Akira [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Iwate Medical University, Cyclotron Research Center, Morioka (Japan); Terasaki, Kazunori [Iwate Medical University, Cyclotron Research Center, Morioka (Japan); Yoshida, Kenji; Beppu, Takaaki; Kubo, Yoshitaka; Fujiwara, Shunrou [Iwate Medical University, Department of Neurosurgery, Morioka (Japan); Tsushima, Eiki [Hirosaki University, Graduate School of Health Sciences, Hirosaki (Japan)

    2013-10-15

    In patients with unilateral internal carotid or middle cerebral artery (ICA or MCA) occlusive disease, the degree of crossed cerebellar hypoperfusion that is evident within a few months after the onset of stroke may reflect cerebral metabolic rate of oxygen in the affected cerebral hemisphere relative to that in the contralateral cerebral hemisphere. The aim of the present study was to determine whether the ratio of blood flow asymmetry in the cerebellar hemisphere to blood flow asymmetry in the cerebral hemisphere on positron emission tomography (PET) and single photon emission computed tomography (SPECT) correlates with oxygen extraction fraction (OEF) asymmetry in the cerebral hemisphere on PET in patients with chronic unilateral ICA or MCA occlusive disease and whether this blood flow ratio on SPECT detects misery perfusion in the affected cerebral hemisphere in such patients. Brain blood flow and OEF were assessed using {sup 15}O-PET and N-isopropyl-p-[{sup 123}I]iodoamphetamine ({sup 123}I-IMP) SPECT, respectively. All images were anatomically standardized using SPM2. A region of interest (ROI) was automatically placed in the bilateral MCA territories and in the bilateral cerebellar hemispheres using a three-dimensional stereotaxic ROI template, and affected-to-contralateral asymmetry in the MCA territory or contralateral-to-affected asymmetry in the cerebellar hemisphere was calculated. Sixty-three patients with reduced blood flow in the affected cerebral hemisphere on {sup 123}I-IMP SPECT were enrolled in this study. A significant correlation was observed between MCA ROI asymmetry of PET OEF and the ratio of cerebellar hemisphere asymmetry of blood flow to MCA ROI asymmetry of blood flow on PET (r = 0.381, p = 0.0019) or SPECT (r = 0.459, p = 0.0001). The correlation coefficient was higher when reanalyzed in a subgroup of 43 patients undergoing a PET study within 3 months after the last ischemic event (r = 0.541, p = 0.0001 for PET; r = 0.609, p < 0

  15. Detection and assessment of unstable angina using myocardial perfusion imaging: Comparison between technetium-99m sestamibi SPECT and 12-lead electrocardiogram

    International Nuclear Information System (INIS)

    Gregoire, J.; Theroux, P.

    1990-01-01

    Forty-five studies using technetium-99m (Tc-99m) sestamibi single photon emission computed tomography (SPECT) were performed on patients hospitalized for spontaneous chest pain suggestive of myocardial ischemia. The studies were done after an injection during an episode of chest pain and a repeated injection when the patients were free of pain. All patients were hospitalized with a presumed diagnosis of unstable angina, and none had evidence of a previous myocardial infarction. The presence of a perfusion defect observed with Tc-99m sestamibi injected during chest pain had a 96% sensitivity and a 79% specificity for the detection of significant coronary artery disease (stenosis greater than or equal to 50%) on subsequent angiography. When the criterion of a larger perfusion defect during pain compared to absence of pain was used, the sensitivity was 81% and the specificity was 84%. In contrast, transient electrocardiographic ischemic changes during pain had a sensitivity of 35% and a specificity of 68%; electrocardiographic changes during or outside episodes of chest pain had a sensitivity of 65% and a specificity of 63% for the diagnosis. Tc-99m sestamibi SPECT represents a reliable noninvasive diagnostic tool that could aid in the diagnosis of myocardial ischemia in patients with spontaneous chest pain and provide additional information to that provided by the electrocardiogram

  16. Hilar accumulation of gallium-67 in patients with normal chest radiographs

    International Nuclear Information System (INIS)

    Hoshi, Hiroaki; Yamada, Hiroki; Kawahira, Kozaburo; Watanabe, Katsushi

    1982-01-01

    Gallium-67 scintigraphy is a useful screening test to detect malignant or inflammatory lesions. However, the accumulations of Gallium-67 in the normal pulmonary hilum are found in some cases. So, 277 cases with Gallium-67 scintigraphy were discussed. The hilar accumulation of Gallium-67 was classified into four grades, namely Grade 0: no Gallium-67 uptake, Grade I: low Gallium-67 uptake, Grade II: moderate Gallium-67 uptake, and Grade III: high Gallium-67 uptake. Gallium-67 uptake was found in 38 of 277 cases (14%). Thirty cases of these were estimated as Grade I (79%). Cases with Grade II were 20.3%, and only two cases were Grade III (0.7%). Gallium-67 accumulation, was bilateral in 28 cases out of 38 and cases with Gallium-67 accumulation increased with age. Twenty five of the 38 cases with Gallium-67 accumulation had such findings as suggesting old pulmonary inflammation though they had no symptoms of respiratory diseases. This study suggests that hilar Gallium-67 accumulation has no correlation with the active inflammation of the lymphnodes. (author)

  17. Aluminum gallium nitride (GaN)/GaN high electron mobility transistor-based sensors for glucose detection in exhaled breath condensate.

    Science.gov (United States)

    Chu, Byung Hwan; Kang, Byoung Sam; Hung, Sheng Chun; Chen, Ke Hung; Ren, Fan; Sciullo, Andrew; Gila, Brent P; Pearton, Stephen J

    2010-01-01

    Immobilized aluminum gallium nitride (AlGaN)/GaN high electron mobility transistors (HEMTs) have shown great potential in the areas of pH, chloride ion, and glucose detection in exhaled breath condensate (EBC). HEMT sensors can be integrated into a wireless data transmission system that allows for remote monitoring. This technology offers the possibility of using AlGaN/GaN HEMTs for extended investigations of airway pathology of detecting glucose in EBC without the need for clinical visits. HEMT structures, consisting of a 3-microm-thick undoped GaN buffer, 30-A-thick Al(0.3)Ga(0.7)N spacer, and 220-A-thick silicon-doped Al(0.3)Ga(0.7)N cap layer, were used for fabricating the HEMT sensors. The gate area of the pH, chloride ion, and glucose detection was immobilized with scandium oxide (Sc(2)O(3)), silver chloride (AgCl) thin film, and zinc oxide (ZnO) nanorods, respectively. The Sc(2)O(3)-gated sensor could detect the pH of solutions ranging from 3 to 10 with a resolution of approximately 0.1 pH. A chloride ion detection limit of 10(-8) M was achieved with a HEMT sensor immobilized with the AgCl thin film. The drain-source current of the ZnO nanorod-gated AlGaN/GaN HEMT sensor immobilized with glucose oxidase showed a rapid response of less than 5 seconds when the sensor was exposed to the target glucose in a buffer with a pH value of 7.4. The sensor could detect a wide range of concentrations from 0.5 nM to 125 microM. There is great promise for using HEMT-based sensors to enhance the detection sensitivity for glucose detection in EBC. Depending on the immobilized material, HEMT-based sensors can be used for sensing different materials. These electronic detection approaches with rapid response and good repeatability show potential for the investigation of airway pathology. The devices can also be integrated into a wireless data transmission system for remote monitoring applications. This sensor technology could use the exhaled breath condensate to measure the

  18. Increased rCBF in gray matter heterotopias detected by SPECT using 99mTc hexamethyl-propylenamine oxime

    International Nuclear Information System (INIS)

    Henkes, H.; Klinikum Rudolf Virchow, Berlin; Hosten, N.; Cordes, M.; Neumann, K.; Hansen, M.L.

    1991-01-01

    Imaging findings of morphology and regional cerebral blood flow in two patients suffering from epileptic seizures are presented. CT and MRI revealed heterotopic gray matter as a probable structural correlate, causing the seizure disorder. 99m Tc hexamethyl-propylenamine oxime (HM-PAO) SPECT demonstrated focally increased regional cerebral blood flow in both patients in the areas of their heterotopic lesions. Heterotopic and orthotopic gray matter seem to have similar features in terms of regional perfusion. A focally increased brain perfusion in interictal epileptic patients may indicate an underlying migration anomaly. (orig.)

  19. The value of SPECT in the detection of stress injury to the pars interarticularis in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Grant Frederick D

    2010-03-01

    Full Text Available Abstract The medical cost associated with back pain in the United States is considerable and growing. Although the differential diagnosis of back pain is broad, epidemiological studies suggest a correlation between adult and adolescent complaints. Injury of the pars interarticularis is one of the most common identifiable causes of ongoing low back pain in adolescent athletes. It constitutes a spectrum of disease ranging from bone stress to spondylolysis and spondylolisthesis. Bone stress may be the earliest sign of disease. Repetitive bone stress causes bone remodeling and may result in spondylolysis, a non-displaced fracture of the pars interarticularis. A fracture of the pars interarticularis may ultimately become unstable leading to spondylolisthesis. Results in the literature support the use of bone scintigraphy to diagnose bone stress in patients with suspected spondylolysis. Single photon emission computed tomography (SPECT provides more contrast than planar bone scintigraphy, increases the sensitivity and improves anatomic localization of skeletal lesions without exposing the patient to additional radiation. It also provides an opportunity for better correlation with other imaging modalities, when necessary. As such, the addition of SPECT to standard planar bone scintigraphy can result in a more accurate diagnosis and a better chance for efficient patient care. It is our expectation that by improving our ability to correctly diagnose bone stress in patients with suspected injury of the posterior elements, the long-term cost of managing this condition will be lowered.

  20. Comparison of continuous with step and shoot acquisition in SPECT scanning

    International Nuclear Information System (INIS)

    McCarthy, L.; Cotterill, T.; Chu, J.M.G.

    1998-01-01

    Full text: Following the recent advent of continuous acquisition for performing SPECT scanning, it was decided to compare the commonly used Step and Shoot mode of acquisition with the new continuous acquisition mode. The aim of the study is to assess any difference in resolution from the resulting images acquired using the two modes of acquisition. Sequential series of studies were performed on a SPECT phantom using both modes of acquisition. Separate sets of data were collected for both high resolution parallel hole and ultra high resolution fan beam collimators. Clinical data was collected on patients undergoing routine gallium, 99m Tc-MDP bone and 99m Tc-HMPAO brain studies. Separate sequential acquisition in both modes were collected for each patient. The sequence of collection was also alternated. Reconstruction was performed utilising the same parameters for each acquisition. The reconstructed data were assessed visually by blinded observers to detect differences in resolution and image quality. No significant difference in the studies collected by either acquisition modes were detected. The time saved by continuous acquisition could be an advantage

  1. Neuropsychiatry: PET and SPECT

    International Nuclear Information System (INIS)

    Quintana F, Juan Carlos

    2002-01-01

    Functional brain imaging with PET and SPECT have a definitive and well established role in the investigation of a variety of conditions such as dementia, epilepsy and drug addiction. With these methods it is possible to detect early rCBF (regional Cerebral Blood Flow) changes seen in dementia (even before clinical symptoms) and differentiate Alzheimer's disease from other dementias by means of the rCBF pattern change. 18-F-FDG PET imaging is a useful tool in partial epilepsy because both rCBF and brain metabolism are compromised at the epileptogenic focus. During the seizure, rCBF dramatically increases locally. Using SPECT it is possible to locate such foci with 97% accuracy. In drug addiction, particularly with cocaine, functional imaging has proven to be very sensitive to detect brain flow and metabolism derangement early in the course of this condition. These findings are important in many ways: prognostic value, they are used as a powerful reinforcement tool and to monitor functional recovery with rehabilitation. There are many other conditions in which functional brain imaging is of importance such as acute stroke treatment assessment, trauma rehabilitation and in psychiatric and abnormal movement diseases specially with the development of receptor imaging (au)

  2. Attenuation correction for SPECT

    International Nuclear Information System (INIS)

    Hosoba, Minoru

    1986-01-01

    Attenuation correction is required for the reconstruction of a quantitative SPECT image. A new method for detecting body contours, which are important for the correction of tissue attenuation, is presented. The effect of body contours, detected by the newly developed method, on the reconstructed images was evaluated using various techniques for attenuation correction. The count rates in the specified region of interest in the phantom image by the Radial Post Correction (RPC) method, the Weighted Back Projection (WBP) method, Chang's method were strongly affected by the accuracy of the contours, as compared to those by Sorenson's method. To evaluate the effect of non-uniform attenuators on the cardiac SPECT, computer simulation experiments were performed using two types of models, the uniform attenuator model (UAM) and the non-uniform attenuator model (NUAM). The RPC method showed the lowest relative percent error (%ERROR) in UAM (11 %). However, 20 to 30 percent increase in %ERROR was observed for NUAM reconstructed with the RPC, WBP, and Chang's methods. Introducing an average attenuation coefficient (0.12/cm for Tc-99m and 0.14/cm for Tl-201) in the RPC method decreased %ERROR to the levels for UAM. Finally, a comparison between images, which were obtained by 180 deg and 360 deg scans and reconstructed from the RPC method, showed that the degree of the distortion of the contour of the simulated ventricles in the 180 deg scan was 15 % higher than that in the 360 deg scan. (Namekawa, K.)

  3. In vivo detection of small tumour lesions by multi-pinhole SPECT applying a (99m)Tc-labelled nanobody targeting the Epidermal Growth Factor Receptor.

    Science.gov (United States)

    Krüwel, Thomas; Nevoltris, Damien; Bode, Julia; Dullin, Christian; Baty, Daniel; Chames, Patrick; Alves, Frauke

    2016-02-25

    The detection of tumours in an early phase of tumour development in combination with the knowledge of expression of tumour markers such as epidermal growth factor receptor (EGFR) is an important prerequisite for clinical decisions. In this study we applied the anti-EGFR nanobody (99m)Tc-D10 for visualizing small tumour lesions with volumes below 100 mm(3) by targeting EGFR in orthotopic human mammary MDA-MB-468 and MDA-MB-231 and subcutaneous human epidermoid A431 carcinoma mouse models. Use of nanobody (99m)Tc-D10 of a size as small as 15.5 kDa enables detection of tumours by single photon emission computed tomography (SPECT) imaging already 45 min post intravenous administration with high tumour uptake (>3% ID/g) in small MDA-MB-468 and A431 tumours, with tumour volumes of 52.5 mm(3) ± 21.2 and 26.6 mm(3) ± 16.7, respectively. Fast blood clearance with a serum half-life of 4.9 min resulted in high in vivo contrast and ex vivo tumour to blood and tissue ratios. In contrast, no accumulation of (99m)Tc-D10 in MDA-MB-231 tumours characterized by a very low expression of EGFR was observed. Here we present specific and high contrast in vivo visualization of small human tumours overexpressing EGFR by preclinical multi-pinhole SPECT shortly after administration of anti-EGFR nanobody (99m)Tc-D10.

  4. In vivo detection of small tumour lesions by multi-pinhole SPECT applying a 99mTc-labelled nanobody targeting the Epidermal Growth Factor Receptor

    Science.gov (United States)

    Krüwel, Thomas; Nevoltris, Damien; Bode, Julia; Dullin, Christian; Baty, Daniel; Chames, Patrick; Alves, Frauke

    2016-01-01

    The detection of tumours in an early phase of tumour development in combination with the knowledge of expression of tumour markers such as epidermal growth factor receptor (EGFR) is an important prerequisite for clinical decisions. In this study we applied the anti-EGFR nanobody 99mTc-D10 for visualizing small tumour lesions with volumes below 100 mm3 by targeting EGFR in orthotopic human mammary MDA-MB-468 and MDA-MB-231 and subcutaneous human epidermoid A431 carcinoma mouse models. Use of nanobody 99mTc-D10 of a size as small as 15.5 kDa enables detection of tumours by single photon emission computed tomography (SPECT) imaging already 45 min post intravenous administration with high tumour uptake (>3% ID/g) in small MDA-MB-468 and A431 tumours, with tumour volumes of 52.5 mm3 ± 21.2 and 26.6 mm3 ± 16.7, respectively. Fast blood clearance with a serum half-life of 4.9 min resulted in high in vivo contrast and ex vivo tumour to blood and tissue ratios. In contrast, no accumulation of 99mTc-D10 in MDA-MB-231 tumours characterized by a very low expression of EGFR was observed. Here we present specific and high contrast in vivo visualization of small human tumours overexpressing EGFR by preclinical multi-pinhole SPECT shortly after administration of anti-EGFR nanobody 99mTc-D10. PMID:26912069

  5. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, M.C., E-mail: mburgmans@hotmail.com [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Too, C.W., E-mail: too.chow.wei@singhealth.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Kao, Y.H., E-mail: yung.h.kao@gmail.com [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Goh, A.S.W., E-mail: anthony.goh.s.w@sgh.com.sg [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Chow, P.K.H., E-mail: gsupc@singnet.com.sg [Department of General Surgery, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857 (Singapore); Department of Surgical Oncology, National Cancer Center Singapore, 11 Hospital Drive, Singapore 169610 (Singapore); Tan, B.S., E-mail: tan.bien.soo@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Tay, K.H., E-mail: tay.kiang.hiong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Lo, R.H.G., E-mail: richard.lo.h.g@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

    2012-12-15

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  6. Comparison of dobutamine-stress magnetic resonance imaging and dipyridamole-Tl-201-SPECT as alternative strategies for the detection of coronary artery disease in patients not suitable for stress-echocardiography

    International Nuclear Information System (INIS)

    Schmidt, M.; Theissen, P.; Voth, E.; Schicha, H.; Jochims, M.; Baer, F.M.; Crnac, J.; Schneider, C.A.; Erdmann, E.

    2001-01-01

    Aim: During the past decade stress-echocardiography has gained increasing popularity for detection of myocardial ischemia in patients with coronary artery disease. However, about 10% to 15% of the patients submitted for stress-echocardiography do not have an adequate acoustic window. The purpose of this study was to compare high-dose dobutamine-stress magnetic resonance imaging (dobutamine-MRI) with dipyridamole-Tl-201-SPECT (dipyridamole-SPECT) as alternative strategies for detection of myocardial ischemia in patients with inadequate image quality by stress-echocardiography. Patients and Methods: Of 296 patients which were consecutively submitted to stress-echo-cardiography 45 patients (15%) had two or more segments that could not be evaluated according to the 16-segment-model of the American Society of Echocardiography. They underwent dobutamine-MRI and dipyridamole-SPECT studies, which were evaluated using a 28-segment modell. Myocardial segments were attributed to perfusion territories of the coronary arteries. The results of ischemia detection were compared to the results of coronary angiography (stenosis ≥50%). Results: In comparison to coronary angiography dobutamine-MRI yielded a sensitivity of 87%, a specificity of 86%, a positive predictive value of 93%, a negative predictive value of 75% and a diagnostic accuracy of 86%. For dipyridamole-SPECT results were 90%, 86%, 93%, 80% and 89%, respectively. These values were not significantly different. Conclusions: In patients not suitable for stress-echocardiography, both dobutamine-MRI and dipyridamole-SPECT are reliable strategies for detection of myocardial ischemia. Selection is dependent on the patient criteria, technical considerations, local logistics and experience of the observer. (orig.) [de

  7. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    International Nuclear Information System (INIS)

    Burgmans, M.C.; Too, C.W.; Kao, Y.H.; Goh, A.S.W.; Chow, P.K.H.; Tan, B.S.; Tay, K.H.; Lo, R.H.G.

    2012-01-01

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  8. Does gallium uptake in the pulmonary hila predict involvement by non-Hodgkin's lymphoma?

    International Nuclear Information System (INIS)

    Champion, P.E.; Groshar, D.; Hooper, H.R.; Palmer, M.; Catz, Z.; Belch, A.; McEwan, A.

    1992-01-01

    67 Ga imaging of non-Hodgkin's lymphoma is useful for evaluating the presence of viable tumour in a residual mass after treatment. However, we have frequently seen gallium uptake in the pulmonary hila without other evidence of lymphoma. To study the significance of this finding, 79 patients with intermediate grade non-Hodgkin's lymphoma were reviewed. Thirty-seven (47%) had abnormal hilar gallium uptake. Twenty-three of these could be fully evaluated, and only five (22%) had hilar lymphoma. A pattern of bilateral, symmetric hilar uptake was seen in 19 patients, but only one had evidence of lymphoma. In 15 cases, this pattern was seen only on single photon emission computed tomography (SPECT). The aetiology of this uptake remains unknown. It is not treatment related, as 12 patients had hilar gallium uptake prior to chemotherapy. Unless confirmed by other methods, hilar gallium uptake should not be attributed to lymphoma, and should not influence patient management. (Author)

  9. A comparative study between TL-201 SPECT myocardial perfusion scintigraphy and dobutamine stress echocardiography in the detection of coronary artery disease at the Philippine Heart Center

    International Nuclear Information System (INIS)

    Ogbac, R.V.; Martinez, A.O.; Obaldo, J.M.; Monzon, O.P.; Torres, J.F.; Rondilla, L.W.S.; Yap, J.S.; Flores, V.B.; Santos, R.J.; Jara, R.D.

    1996-01-01

    Although thallium-201 SPECT myocardial perfusion scintigraphy (MPS) has shown considerable accuracy for the detection of coronary artery disease (CAD), dobutamine stress echocardiography (DSE), a relatively new method for the detection of CAD had been recently utilized at the Philippine Heart Center. To assess its diagnostic worth versus that of thallium-201 spect myocardial scintigraphy (MPS), we studied 18 patients who underwent both procedures. Coronary angiography (CA) was used as the gold standard. MPS was performed with maximal treadmill exercise or with dipyridamole (0.568 mg/kg over 4 minutes) and Tl-201 was injected at peak stress. DSE was performed by infusing dobutamine at an increment of 5 μg/kg/min up to a maximum of 40. Atropine (0.01%) was added when 85% of maximum predicted heart rate is not achieved. Significant stenosis (>70%) was found in 16 out of 18 patients by CA. The sensitivity for the presence of CAD was 88% (14/16) and 69% (11/16) for MPS and DSE respectively. Specificity was 100% (2/2) for both. PPV was 100% for both while NPV was 50% and 29% for MPS and DSE respectively. Diagnostic accuracies were 89% and 72% for MPS and DSE respectively (P>0.05). Sensitivity for detecting left anterior descending artery (LAD) lesion was 71% 64% for MPS and DSE respectively; specificity was 75% and 100% respectively. For the left circumplex artery (LCX) lesion, both MPS and DSE had a sensitivity of 62% and specificity of 60%. Likewise for the right coronary artery (RCA) lesion, both had a sensitivity of 66% and specificity of 50%. Diagnostic accuracies were equal for both tests at 72% for LAD; 61% for LCX; and 61% for RCA. Kappa tests for association shows ρ values of >0.05 for overall and individual CAD detection suggesting no significant difference between MPS and DSE. Although there is a trend showing better detection of CAD with MPS, this particular study shows that both tests are comparable with regards to detection of the presence of CAD and of

  10. Brain SPECT. SPECT in der Gehirndiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Feistel, H. (Erlangen-Nuernberg Univ., Erlangen (Germany). Nuklearmedizinische Klinik mit Poliklinik)

    1991-12-01

    Brain SPECT investigations have gained broad acceptance since the introduction of the lipophilic tracer Tc-99m-HMPAO. Depending on equipment and objectives in different departments, the examinations can be divided into three groups: 1. Under normal conditions and standardised patient preparation the 'rest' SPECT can be performed in every department with a tomographic camera. In cerebrovascular disease there is a demand for determination of either the perfusion reserve in reversible ischemia or prognostic values in completed stroke. In cases of dementia, SPECT may yield useful results according to differential diagnosis. Central cerebral system involvement in immunologic disease may be estimated with higher sensitivity than in conventional brain imaging procedures. In psychiatric diseases there is only a relative indication for brain SPECT, since results during recent years have been contradictory and may be derived only in interventional manner. In brain tumor diagnostics SPECT with Tl-201 possibly permits grading. In inflammatory disease, especially in viral encephalitis, SPECT may be used to obtain early diagnosis. Normal pressure hydrocephalus can be distinguished from other forms of dementia and, consequently, the necessity for shunting surgery can be recognised. 2. In departments equipped for emergency cases an 'acute' SPECT can be performed in illnesses with rapid changing symptoms such as different forms of migraine, transient global amnesia, epileptic seizures (so-called 'ictal SPECT') or urgent forms like trauma. 3. In cooperation with several departments brain SPECT can be practised as an interventional procedure in clinical and in scientific studies. (orig./MG).

  11. SPECT in psychiatry. SPECT in der Psychiatrie

    Energy Technology Data Exchange (ETDEWEB)

    Barocka, A. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Feistel, H. (Nuklearmedizinische Klinik, Erlangen (Germany)); Ebert, D. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany)); Lungershausen, E. (Psychiatrische Klinik und Poliklinik, Erlangen (Germany))

    1993-08-13

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D[sub 2] and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.)

  12. Layer-by-layer composition and structure of silicon subjected to combined gallium and nitrogen ion implantation for the ion synthesis of gallium nitride

    Energy Technology Data Exchange (ETDEWEB)

    Korolev, D. S.; Mikhaylov, A. N.; Belov, A. I.; Vasiliev, V. K.; Guseinov, D. V.; Okulich, E. V. [Nizhny Novgorod State University (Russian Federation); Shemukhin, A. A. [Moscow State University, Skobeltsyn Institute of Nuclear Physics (Russian Federation); Surodin, S. I.; Nikolitchev, D. E.; Nezhdanov, A. V.; Pirogov, A. V.; Pavlov, D. A.; Tetelbaum, D. I., E-mail: tetelbaum@phys.unn.ru [Nizhny Novgorod State University (Russian Federation)

    2016-02-15

    The composition and structure of silicon surface layers subjected to combined gallium and nitrogen ion implantation with subsequent annealing have been studied by the X-ray photoelectron spectroscopy, Rutherford backscattering, electron spin resonance, Raman spectroscopy, and transmission electron microscopy techniques. A slight redistribution of the implanted atoms before annealing and their substantial migration towards the surface during annealing depending on the sequence of implantations are observed. It is found that about 2% of atoms of the implanted layer are replaced with gallium bonded to nitrogen; however, it is impossible to detect the gallium-nitride phase. At the same time, gallium-enriched inclusions containing ∼25 at % of gallium are detected as candidates for the further synthesis of gallium-nitride inclusions.

  13. I-123 Iofetamine SPECT scan in children with neurological disorders

    International Nuclear Information System (INIS)

    Flamini, J.R.; Konkol, R.J.; Wells, R.G.; Sty, J.R.

    1990-01-01

    I-123 Iofetamine (IMP) single photon emission computed tomography (SPECT) imaging of the brain in 42 patients (ages 14 days to 23 years) was compared with other localizing studies in children with neurological diseases. All had an EEG and at least one imaging study of the brain (computed tomography (CT) or magnetic resonance imaging (MRI), or both). Seventy-eight percent of the patients had an EEG within 24-72 hours of the IMP-SPECT scan. Thirty-five (83%) had a history of seizures, and the remainder had other neurological conditions without a history of seizures. In most cases, a normal EEG reading with normal CT or MRI result predicted a normal SPECT study. When the EEG was abnormal the majority of the IMP-SPECT scans were abnormal and localized the abnormality to the same region. A comparison with CT and MRI showed that structural abnormalities involving the cortex were usually well demonstrated with IMP-SPECT imaging. Structural lesions confined to the white matter were generally not detectable with IMP-SPECT. In a few cases, SPECT scans revealed abnormalities in deep brain areas not identified by EEG. IMP-SPECT imaging is a valuable technique for the detection and localization of abnormal cerebral metabolic activity in children with seizure disorders. A correlation with CT or MRI is essential for proper interpretation of abnormalities detected with IMP SPECT imaging

  14. SPECT quantification of regional radionuclide distributions

    International Nuclear Information System (INIS)

    Jaszczak, R.J.; Greer, K.L.; Coleman, R.E.

    1986-01-01

    SPECT quantification of regional radionuclide activities within the human body is affected by several physical and instrumental factors including attenuation of photons within the patient, Compton scattered events, the system's finite spatial resolution and object size, finite number of detected events, partial volume effects, the radiopharmaceutical biokinetics, and patient and/or organ motion. Furthermore, other instrumentation factors such as calibration of the center-of-rotation, sampling, and detector nonuniformities will affect the SPECT measurement process. These factors are described, together with examples of compensation methods that are currently available for improving SPECT quantification. SPECT offers the potential to improve in vivo estimates of absorbed dose, provided the acquisition, reconstruction, and compensation procedures are adequately implemented and utilized. 53 references, 2 figures

  15. Brain SPECT in children

    International Nuclear Information System (INIS)

    Guyot, M.; Baulieu, J.L.

    1996-01-01

    Brain SPECT in child involves specific trends regarding the patient cooperation, irradiation, resolution and especially interpretation because of the rapid scintigraphic modifications related to the brain maturation. In a general nuclear medicine department, child brain SPECT represents about 2 % of the activity. The choice indications are the perfusion children: thallium and MIBI in brain tumours, pharmacological and neuropsychological interventions. In the future, brain dedicated detectors and new radiopharmaceuticals will promote the development of brain SPECT in children. (author)

  16. Clinical utility of 18-FDG-PET with a modified SPECT-camera using molecular coincidence detection in oncology

    International Nuclear Information System (INIS)

    Gabriel, M. F.

    1998-09-01

    Malignant diseases are belonging to one of the most frequent reasons for mortality and morbidity of people in industrialized countries. In order to avoid inadequate therapy such as unnecessary operations etc. accurate diagnostic techniques are needed to assess malignancy of proven lesions, for staging of cancer or to assess success of therapy. Many studies have reported the value of PET in such cases. Because of limited financial resources we started PET with a Dual-head-SPECT-camera modified with a MCD-module in February 1997 in order to obtain quick access to clinical 18-FDG studies. The aim of this work was to compare the results of our system with reports of the so called 'state of the art'-PET and with other diagnostic techniques used in clinical oncology. So far 124 studies were performed with the MCD-mode using a standardized investigation protocol between February 1997 and May 1998. The applied dose of 18-FDG for oncological studies was about 185 MBq. The tracer was supplied from the radio-pharmaceutical unit of the Department of Nuclear Medicine, Klinikum Rechts der Isar, Technische Universitaet Muenchen. The obtained results were carefully compared with CT, MRI and conventional radiology. In addition, the final diagnosis (based on histology, surgical reports, autopsy and follow up) was also considered. Oncological studies were done either to assess malignancy in certain lesions (n = 25), for staging cancer (n = 77), or to assess success of therapy (n = 22). Sensitivity and specificity for all oncological cases were 99 % and 89 % respectively. One false negative scan was a pretreated CNS-lymphoma, where false positive studies were due to inflammation. (author)

  17. Cutaneous gallium uptake in patients with AIDS with mycobacterium avium-intracellulare septicemia

    International Nuclear Information System (INIS)

    Allwright, S.J.; Chapman, P.R.; Antico, V.F.; Gruenewald, S.M.

    1988-01-01

    Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection

  18. A case of muscular sarcoidosis diagnosed by gallium-67 scintigraphy and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sohn, Hyung Sun; Kim, Euy Neyng

    1999-01-01

    Gallium-67 scintigraphy is helpful in the assessment of active extrapulmonary sarcoidosis. Muscular involvement of sarcoidosis is often asymptomatic or nonspecific, and laboratory examinations do not provide convincing evidence of muscular involvement. We report a case of muscular sarcoidosis, which was detected by gallium-67 scintigraphy. In a patient who was suffering from fever and arthalgia of knee joint, gallium-67 scintigraphy showed mediastinal and hilar involvement of sarcoidosis with unexpected extensive muscular uptake. Magnetic resonance imaging revealed the detailed depiction of intramuscular infiltration of sarcoid granuloma. Gallium-67 scintigraphy is useful in detecting inflammatory muscular involvement of sarcoidosis as well as other multiorgan involvement

  19. Detection of myocardial stunning with gated SPECT and its relationship with location, extension and severity of perfusion defects induced by exercise or pharmacologic stress

    International Nuclear Information System (INIS)

    Mut, F.; Beretta, M.; Vidal, I.; Rener, A.; Alonso, O.

    2002-01-01

    Aim: To investigate the relationship between transient ventricular dysfunction detected by gated SPECT with the location, extension and severity of ischemic areas in patients with reversible perfusion defects. Material and Methods: We retrospectively studied 83 patients (61±11 yrs., 61 men, 27 with previous MI) submitted for coronary artery disease (CAD) evaluation with 99mTc-MIBI gated SPECT using a 2-day protocol whose perfusion imaging pattern had been reported positive for myocardial ischemia. Stress test was exercise in 54 cases, dipyridamole in 28 and dobutamine in 1. Previous work from our group demonstrated up to 12% change in LVEF from rest to post-stress in a population with low likelihood of CAD and a normal perfusion pattern. Thus, according to % variation of left ventricular ejection fraction (LVEF) from rest to post-stress we further divided the population into 2 subgroups, (A) with less than 12% change in LVEF (n=56) and (B) with more than 12% negative variation (n=27). For evaluation of perfusion, a simplified 7-segment division of the myocardium was used and a combined ischemic score was obtained by multiplying the number of segments with reversible defects by the 1-4 assigned severity score. Results: There was no significant difference between the two groups regarding age, gender, stress result (clinical or ECG), number of fixed perfusion defects or rest LVEF. Dipyridamole test was more frequent among patients of group B. Post-stress LVEF was 49±14% for group A and 41±15% for group B, p=0.0125. Combined ischemic score was 6.82±6.5 vs. 11.96±12 respectively, p=0.014. In patients of group A, defects corresponding to the right coronary territory were more frequent, while the left descending artery territory was more commonly affected in group B patients, however this was not statistically significant. Left circumflex territory was equally affected in both groups. Conclusion: Transient ventricular dysfunction after a stress test can be

  20. Prognostic implications of post-stress ejection fraction decrease detected by gated SPECT in the absence of stress-induced perfusion abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Dona, Manjola; Massi, Lucia; Settimo, Leonardo; Bartolini, Matteo; Gianni, Gianluca; Pupi, Alberto; Sciagra, Roberto [University of Florence, Nuclear Medicine Unit, Department of Clinical Physiopathology, Florence (Italy)

    2011-03-15

    The prognostic meaning of a post-stress ejection fraction (EF) decrease detected by perfusion gated SPECT is still unclear. We therefore followed up patients with post-stress EF decrease in the absence of stress-induced perfusion abnormalities. We prospectively enrolled 57 consecutive patients with post-stress EF drop {>=} 5 EF units and summed difference score (SDS) {<=} 1. They were followed up for more than 1 year and their outcome was compared with a group of sex- and age-matched controls with the same SDS but without EF decrease. During follow-up there were 13 events (1 cardiac death, 1 non-fatal myocardial infarction, 1 congestive heart failure and 10 late revascularizations). In the control group we registered six events. There was a significant difference (p < 0.0001) between the event-free survival curves of the two groups. The event rate of patients with post-stress EF decrease {>=} 5 EF units is relatively high and is significantly worse than that of a control group of patients with similarly normal SDS but without EF changes. Therefore, a post-stress EF decrease without stress-induced perfusion abnormalities should be cautiously interpreted. (orig.)

  1. Improved Accuracy of Myocardial Perfusion SPECT for the Detection of Coronary Artery Disease by Utilizing a Support Vector Machines Algorithm

    Science.gov (United States)

    Arsanjani, Reza; Xu, Yuan; Dey, Damini; Fish, Matthews; Dorbala, Sharmila; Hayes, Sean; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2012-01-01

    We aimed to improve the diagnostic accuracy of automatic myocardial perfusion SPECT (MPS) interpretation analysis for prediction of coronary artery disease (CAD) by integrating several quantitative perfusion and functional variables for non-corrected (NC) data by support vector machines (SVM), a computer method for machine learning. Methods 957 rest/stress 99mtechnetium gated MPS NC studies from 623 consecutive patients with correlating invasive coronary angiography and 334 with low likelihood of CAD (LLK < 5% ) were assessed. Patients with stenosis ≥ 50% in left main or ≥ 70% in all other vessels were considered abnormal. Total perfusion deficit (TPD) was computed automatically. In addition, ischemic changes (ISCH) and ejection fraction changes (EFC) between stress and rest were derived by quantitative software. The SVM was trained using a group of 125 pts (25 LLK, 25 0-, 25 1-, 25 2- and 25 3-vessel CAD) using above quantitative variables and second order polynomial fitting. The remaining patients (N = 832) were categorized based on probability estimates, with CAD defined as (probability estimate ≥ 0.50). The diagnostic accuracy of SVM was also compared to visual segmental scoring by two experienced readers. Results Sensitivity of SVM (84%) was significantly better than ISCH (75%, p < 0.05) and EFC (31%, p < 0.05). Specificity of SVM (88%) was significantly better than that of TPD (78%, p < 0.05) and EFC (77%, p < 0.05). Diagnostic accuracy of SVM (86%) was significantly better than TPD (81%), ISCH (81%), or EFC (46%) (p < 0.05 for all). The Receiver-operator-characteristic area-under-the-curve (ROC-AUC) for SVM (0.92) was significantly better than TPD (0.90), ISCH (0.87), and EFC (0.60) (p < 0.001 for all). Diagnostic accuracy of SVM was comparable to the overall accuracy of both visual readers (85% vs. 84%, p < 0.05). ROC-AUC for SVM (0.92) was significantly better than that of both visual readers (0.87 and 0.88, p < 0.03). Conclusion Computational

  2. Incremental value of 99mTc-HYNIC-TOC SPECT/CT over whole-body planar scintigraphy and SPECT in patients with neuroendocrine tumours.

    Science.gov (United States)

    Trogrlic, Mate; Težak, Stanko

    2017-06-12

    The aim of this study was to evaluate the additional value of 99m Tc-HYNIC-TOC SPECT/CT over planar whole-body (WB) scintigraphy and SPECT alone in the detection and accurate localisation of neuroendocrine tumour (NET) lesions. This study included 65 patients with a definitive histological diagnosis of NET prior to scintigraphy. Planar WB scintigraphy, SPECT, and SPECT/CT images were acquired at 4 h post-administration of 670 MBq 99m Tc-HYNIC-TOC. Additional SPECT images at 10 min after tracer administration were also acquired. Clinical and imaging follow-up findings were considered as the reference standards (minimum follow-up period, 15 months). Patient and lesion-based analyses of the efficacies of the imaging modalities were performed. While 38 patients exhibited metastasis of NETs, 27 presented no evidence of metastasis. Upon patient-based analysis, the sensitivity and specificity of SPECT/CT were found to be 88.9 and 79.3 %, respectively. The diagnostic accuracies of WB scintigraphy, 4h-SPECT, and SPECT/CT were 72.3, 73.8, and 84.6 %, respectively. The area under curve (AUC) value for SPECT/CT (0.84) was the highest, followed by those for 4h-SPECT (0.75) and WB scintigraphy (0.74). The accuracy and AUC values of SPECT/CT were significantly better compared to those of WB scintigraphy (p < 0.001), 10 min-SPECT (p < 0.001), and 4 h-SPECT (p = 0.001). The findings of SPECT/CT led to the change in treatment plan of 11 patients (16.9 %). The sensitivity and diagnostic accuracy of SPECT/CT in the evaluation of NET lesions outperforms planar WB imaging or SPECT alone.

  3. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    International Nuclear Information System (INIS)

    Lee, Sang Kun; Lee, Dong Soo

    2003-01-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test

  4. Functional neuroimaging in epilepsy: FDG-PET and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Kun; Lee, Dong Soo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    Finding epileptogenic zone is the most important step for the successful epilepsy surgery. F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and single photon emission computed tomography (SPECT) can be used in the localization of epileptogenic foci. In medial temporal lobe epilepsy, the diagnostic sensitivity of FDG-PET and ictal SPECT is excellent. However, detection of hippocampal sclerosis by MRI is so certain that use of FDG-PET and ictal SPECT in medial temporal lobe epilepsy is limited for some occasions. In neocortical epilepsy, the sensitivities of FDG-PET or ictal SPECT are fair. However, FDG-PET and ictal SPECT can have a crucial role in the localization of epileptogenic foci for non-lesional neocortical epilepsy. Interpretation of FDG-PET has been recently advanced by voxel-based analysis and automatic volume of interest analysis based on a population template. Both analytical methods can aid the objective diagnosis of epileptogenic foci. lctal SPECT was analyzed using subtraction methods and voxel-based analysis. Rapidity of injection of tracers, ictal EEG findings during injection of tracer, and repeated ictal SPECT were important technical issues of ictal SPECT. SPECT can also be used in the evaluation of validity of Wada test.

  5. Methods of gated-blood-pool-spect data processing

    International Nuclear Information System (INIS)

    Kosa, I.; Mester, J.; Tanaka, M.; Csernay, L.; Mate, E.; Szasz, K.

    1991-01-01

    Three techniques of gated SPECT were evaluated. The methods of Integral SPECT (ISPECT), enddyastole-endsystole SPECT (ED-ES SPECT) and Fourier SPECT were adapted and developed on the Hungarian nuclear medicine data processing system microSEGAMS. The methods are based on data reduction before back projection which results in processing times acceptable for the clinical routine. The clinical performance of the introduced techniques was tested in 10 patients with old posterior myocardial infarction and in 5 patients without cardiac disease. The left ventricular ejection faction determined by ISPECT correlated well with the planar values. The correlation coefficient was 0.89. The correlation coefficient of EF values determined by ED-ES SPECT and planar radionuclide ventriculography was lower (0.70). For the identification of left ventricular wall motion abnormalities ED-ES SPECT and Fourier SPECT exhibited a favourable performance, but ISPECT only moderate suitability. In the detection of regional phase delay Fourier-SPECT demonstrated higher sensitivity than the planar radionuclide ventriculography. (author) 4 refs.; 3 figs.; 2 tabs

  6. Gallium accumulation in early pulmonary Pneumocystis carinii infection

    International Nuclear Information System (INIS)

    Stevens, D.A.; Allegra, J.C.

    1986-01-01

    The accumulation of gallium 67 citrate in pulmonary Pneumocystis carinii is well known. The sensitivity of gallium uptake in detecting early inflammatory processes, even when conventional roentgenograms are normal, would seem to make it possible in immunocompromised patients to make a presumptive diagnosis of this serious infection early in its course without using invasive techniques to demonstrate the organism. However, the presence of gallium uptake in radiation pneumonitis, pulmonary drug toxicity, and other processes that also occur in this group limit its usefulness. In our two patients--a young woman with Hodgkin's disease and an elderly woman with small cell lung cancer--this technique proved helpful. Although the latter patient was successfully treated empirically, such empiric treatment should be reserved for patients unable or unwilling to undergo invasive tests. Pulmonary gallium uptake in patients with respiratory symptoms, even with a normal chest film, should prompt attempts to directly demonstrate the organism

  7. Gallium and copper radiopharmaceutical chemistry

    International Nuclear Information System (INIS)

    Green, M.A.

    1991-01-01

    Gallium and copper radionuclides have a long history of use in nuclear medicine. Table 1 presents the nuclear properties of several gallium and copper isotopes that either are used in the routine practice of clinical nuclear medicine or exhibit particular characteristics that might make them useful in diagnostic or therapeutic medicine. This paper will provide some historic perspective along with an overview of some current research directions in gallium and copper radiopharmaceutical chemistry. A more extensive review of gallium radiopharmaceutical chemistry has recently appeared and can be consulted for a more in-depth treatment of this topic

  8. Usefulness of CT based SPECT Fusion Image in the lung Disease : Preliminary Study

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Lyu, Kwang Yeul; Kim, Tae Hyung; Shin, Ji Yun

    2012-01-01

    Recently, SPECT/CT system has been applied to many diseases, however, the application is not extensively applied at pulmonary disease. Especially, in case that, the pulmonary embolisms suspect at the CT images, SPECT is performed. For the accurate diagnosis, SPECT/CT tests are subsequently undergoing. However, without SPECT/CT, there are some limitations to apply these procedures. With SPECT/CT, although, most of the examination performed after CT. Moreover, such a test procedures generate unnecessary dual irradiation problem to the patient. In this study, we evaluated the amount of unnecessary irradiation, and the usefulness of fusion images of pulmonary disease, which independently acquired from SPECT and CT. Using NEMA PhantomTM (NU2-2001), SPECT and CT scan were performed for fusion images. From June 2011 to September 2010, 10 patients who didn't have other personal history, except lung disease were selected (male: 7, female: 3, mean age: 65.3±12.7). In both clinical patient and phantom data, the fusion images scored higher than SPECT and CT images. The fusion images, which is combined with pulmonary vessel images from CT and functional images from SPECT, can increase the detection possibility in detecting pulmonary embolism in the resin of lung parenchyma. It is sure that performing SPECT and CT in integral SPECT/CT system were better. However, we believe this protocol can give more informative data to have more accurate diagnosis in the hospital without integral SPECT/CT system.

  9. 123I-iomazenil brain receptor SPECT in focal epilepsy. In comparison with 99mTc-HMPAO brain SPECT, MRI and Video/EEG monitoring

    International Nuclear Information System (INIS)

    Xu Hao; Wang Tongge; Huang Li; Michael Cordes

    1998-01-01

    Purpose: To evaluate the clinical value of 123 I-Iomazenil brain receptor SPECT in diagnosis of focal epilepsy in comparison with 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Methods 123 I-Iomazenil brain receptor SPECT was performed on 40 patients with focal epilepsy. The results were compared with those obtained by 99m Tc-HMPAO brain SPECT, MRI and Video/EEG monitoring. Results: In 40 patients, the sensitivity of Video/EEG monitoring for localization of epileptogenic area was 95% (38/40). The sensitivity of 123 I-iomazenil brain receptor SPECT, 99m Tc-HMPAO brain SPECT and MRI for localization of epileptogenic area compared with Video/EEG monitoring ('gold standard') was 65.8%(25/38), 55.3%(21/38) and 47.4%(18/38), respectively. The localization of epileptogenic area with 123 I-Iomazenil brain receptor SPECT was in concordance with Video/EEG monitoring in 20 patients, 99m Tc-HMPAO brain SPECT in 15 patients and MRI in 16 patients, respectively. The sensitivity of 123 I-Iomazenil brain receptor SPECT combined with MRI for localization of epileptogenic area was 84.2%(32/38). Conclusions: 123 I-Iomazenil brain receptor SPECT is a useful method in detecting and localizing epileptogenic area. The combination of 123 I-Iomazenil brain receptor SPECT and MRI has a high sensitivity for detecting epileptogenic area

  10. Preparation and anatomical distribution study of 67Ga-alginic acid nanoparticles for SPECT purposes in rainbow trout (Oncorhynchus mykiss

    Directory of Open Access Journals (Sweden)

    Heidarieh Marzieh

    2014-12-01

    Full Text Available Ergosan contains 1% alginic acid extracted from two brown sea weeds. Little is known about the target organs and anatomical distribution of Ergosan (alginic acid in fish. Therefore, feasibility of developing alginic acid nanoparticles to detect target organ in rainbow trout is interesting. To make nanoparticles, Ergosan extract (alginic acid was irradiated at 30 kGy in a cobalt-60 irradiator and characterized by transmission electron microscopy (TEM and Fourier transform infrared spectroscopy (FTIR. Results from TEM images showed that particle sizes of irradiated alginic acid ranged from 30 to 70 nm. The FTIR results indicated that gamma irradiation had no significant influence on the basic structure of alginic acid. Later, alginic acid nanoparticles were successively labelled with 67Ga-gallium chloride. The biodistribution of irradiated Ergosan in normal rainbow trout showed highest uptake in intestine and kidney and then in liver and kidney at 4- and 24-h post injection, respectively. Single-photon emission computed tomography (SPECT images also demonstrated target specific binding of the tracer at 4- and 24-h post injection. In conclusion, the feed supplemented with alginic acid nanoparticles enhanced SPECT images of gastrointestinal morphology and immunity system in normal rainbow trout.

  11. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Barocka, A.; Feistel, H.; Ebert, D.; Lungershausen, E.

    1993-01-01

    This review presents Single Photon Emission Computed Tomography (SPECT) as a powerful tool for clinical use and research in psychiatry. Its focus is on regional cerebral blood flow, measured with technetium labelled HMPAO. In addition, first results with brain receptor imaging, concerning dopamin-D 2 and benzodiazepine receptors, are covered. Due to major improvements in image quality, and impressive number of results has been accumulated in the past three years. The authors caution against using SPECT results as markers for disease entities. A finding like 'hypofrontality' is considered typical of a variety of mental disorders. Clearly both, more experience with SPECT and contributions from psychopathology, are needed. (orig.) [de

  12. Myocardial multilayer strain does not provide additional value for detection of myocardial viability assessed by SPECT imaging over and beyond standard strain.

    Science.gov (United States)

    Orloff, Elisabeth; Fournier, Pauline; Bouisset, Frédéric; Moine, Thomas; Cournot, Maxime; Elbaz, Meyer; Carrié, Didier; Galinier, Michel; Lairez, Olivier; Cognet, Thomas

    2018-05-14

    The aim of this study was to evaluate the value of multilayer strain analysis to the assessment of myocardial viability (MV) through the comparison of both speckle tracking echocardiography and single-photon emission computed tomography (SPECT) imaging. We also intended to determine which segmental longitudinal strain (LS) cutoff value would be optimal to discriminate viable myocardium. We included 47 patients (average age: 61 ± 11 years) referred to our cardiac imaging center for MV evaluation. All patients underwent transthoracic echocardiography with measures of LS, SPECT, and coronary angiography. In all, 799 segments were analyzed. We correlated myocardial tracer uptake by SPECT with sub-endocardial, sub-epicardial, and mid-segmental LS values with r = .514 P Multilayer strain analysis does not evaluate MV with more accuracy than standard segmental LS analysis. © 2018 Wiley Periodicals, Inc.

  13. Role of Gallium and labeled leukocyte scintigraphy in AIDS patient

    International Nuclear Information System (INIS)

    Palestro, C.J.; Goldsmith, S.J.

    1995-01-01

    Because AIDS patients frequently present with minimal symptomatology, radionuclide imaging with its ability to survey the entire body, is especially valuable. Gallium-67 citrate, the most commonly performed radionuclide study for localizing infection in these patients, is most useful for detecting opportunistic infections, especially in the thorax. A negative gallium scan, particularly when the chest X-ray is unremarkable, rules strongly against pulmonary disease. A negative gallium scan in a patient with an abnormal chest X-ray and Kaposi's sarcoma, suggests that the patient's respiratory distress is related to the neoplasm. Diffuse pulmonary parenchymal uptake of gallium in the HIV (+) patient is most often associated with PCP. While there are other causes of diffuse pulmonary uptake, the more intense or heterogeneous the uptake, the more likely the patient is to have PCP. Focal pulmonary uptake is usually associated with bacterial pneumonia although PCP may occasionally present in this fashion. Lymph node uptake of gallium is usually associated with Mycob acterium avium complex, tuberculosis, or Iymphoma. When corresponding abnormalities are present on thallium scintigraphy lymphoma is likely. Gallium positive, thallium negative, studies suggest mycobacterial disease. Labeled leukocyte imaging is not useful for detecting opportunistic infections probably because of the inflammatory response incited by these organisms. Leukocyte imaging is, however, more sensitive for detecting bacterial pneumonia. In the abdomen, gallium imaging is most useful for identifying lymphadenopathy, while labeled leukocyte imaging is superior for detecting AlDS-associated colitides. In summary, radionuclide studies are valuable diagnostic modalities in AIDS. Their success can be maximized by tailoring the study to the individual's needs

  14. Detection of low-grade prosthetic joint infections using {sup 99m}Tc-antigranulocyte SPECT/CT: initial clinical results

    Energy Technology Data Exchange (ETDEWEB)

    Graute, Vera; Lehner, Sebastian; Haug, Alexander; Bartenstein, Peter; Hacker, Marcus [University of Munich, Department of Nuclear Medicine, Munich (Germany); Feist, Markus; Mueller, Peter Ernst [University of Munich, Department of Orthopedic Medicine, Munich (Germany)

    2010-09-15

    Low-grade joint infections are characterized by infiltration of granulocytes, which mediate aspects of inflammatory changes. We evaluated retrospectively the contribution of SPECT/CT as an addition to planar scintigraphy with {sup 99m}Tc-labelled antigranulocyte antibodies for diagnosing and localizing low-grade joint infections. Planar scintigraphy using {sup 99m}Tc-labelled antigranulocyte BW 250/183 antibodies was performed in 31 patients with suspected joint infections at 5 min, 5 h and 24 h after injection, with additional SPECT/CT performed 6 h after injection. With reference to gold standard clinical data, we assessed the diagnostic sensitivity of scintigraphy alone and in conjunction with SPECT/CT. Joint infections were diagnosed clinically in 9 of the 31 patients (1 hip and 8 knee prostheses). Planar scintigraphy revealed 6 true-positives, 13 true-negatives, 9 false-positives and 3 false-negative results, indicating sensitivity, specificity, positive and negative predictive values of, respectively, 0.66, 0.60, 0.4 and 0.81. With the addition of SPECT images, corresponding sensitivity, specificity, positive and negative predictive values increased to 0.89, 0.45, 0.40 and 0.91. Implementation of fused SPECT/CT led to a further increase to 0.89, 0.73, 0.57 and 0.94. Relative to planar scintigraphy, SPECT with and without CT substantially improved the utility of imaging with {sup 99m}Tc-labelled antigranulocyte antibodies for diagnosis and localization of suspected joint infections. Optimal accuracy was obtained through image fusion, which permitted anatomical allocation of foci of pathological tracer accumulation as well as providing information on the extent of the infection. This imaging method seems suited for selection of patients requiring surgical therapy. (orig.)

  15. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  16. Inhalation developmental toxicology studies: Gallium arsenide in mice and rats

    Energy Technology Data Exchange (ETDEWEB)

    Mast, T.J.; Greenspan, B.J.; Dill, J.A.; Stoney, K.H.; Evanoff, J.J.; Rommereim, R.L.

    1990-12-01

    Gallium arsenide is a crystalline compound used extensively in the semiconductor industry. Workers preparing solar cells and gallium arsenide ingots and wafers are potentially at risk from the inhalation of gallium arsenide dust. The potential for gallium arsenide to cause developmental toxicity was assessed in Sprague- Dawley rats and CD-1 (Swiss) mice exposed to 0, 10, 37, or 75 mg/m{sup 3} gallium arsenide, 6 h/day, 7 days/week. Each of the four treatment groups consisted of 10 virgin females (for comparison), and {approx}30 positively mated rats or {approx}24 positively mated mice. Mice were exposed on 4--17 days of gestation (dg), and rats on 4--19 dg. The day of plug or sperm detection was designated as 0 dg. Body weights were obtained throughout the study period, and uterine and fetal body weights were obtained at sacrifice (rats, 20 dg; mice, 18 dg). Implants were enumerated and their status recorded. Live fetuses were sexed and examined for gross, visceral, skeletal, and soft-tissue craniofacial defects. Gallium and arsenic concentrations were determined in the maternal blood and uterine contents of the rats (3/group) at 7, 14, and 20 dg. 37 refs., 11 figs., 30 tabs.

  17. Gallium--A smart metal

    Science.gov (United States)

    Foley, Nora; Jaskula, Brian W.

    2013-01-01

    Gallium is a soft, silvery metallic element with an atomic number of 31 and the chemical symbol Ga. The French chemist Paul-Emile Lecoq de Boisbaudran discovered gallium in sphalerite (a zinc-sulfide mineral) in 1875 using spectroscopy. He named the element "gallia" after his native land of France (formerly Gaul; in Latin, Gallia). The existence of gallium had been predicted in 1871 by Dmitri Mendeleev, the Russian chemist who published the first periodic table of the elements. Mendeleev noted a gap in his table and named the missing element "eka-aluminum" because he determined that its location was one place away from aluminum in the table. Mendeleev thought that the missing element (gallium) would be very much like aluminum in its chemical properties, and he was right. Solid gallium has a low melting temperature (~29 degrees Celsius, or °C) and an unusually high boiling point (~2,204 °C). Because of these properties, the earliest uses of gallium were in high-temperature thermometers and in designing metal alloys that melt easily. The development of a gallium-based direct band-gap semiconductor in the 1960s led to what is now one of the most well-known applications for gallium-based products--the manufacture of smartphones and data-centric networks.

  18. SPECT in patients with cortical visual loss.

    Science.gov (United States)

    Silverman, I E; Galetta, S L; Gray, L G; Moster, M; Atlas, S W; Maurer, A H; Alavi, A

    1993-09-01

    Single-photon emission computed tomography (SPECT) with 99mTc-hexamethylpropyleneamine oxime (HMPAO) was used to investigate changes in cerebral blood flow in seven patients with cortical visual impairment. Traumatic brain injury (TBI) was the cause of cortical damage in two patients, cerebral ischemia in two patients and carbon monoxide (CO) poisoning, status epilepticus and Alzheimer's Disease (AD) each in three separate patients. The SPECT scans of the seven patients were compared to T2-weighted magnetic resonance image (MRI) scans of the brain to determine the correlation between functional and anatomical findings. In six of the seven patients, the qualitative interpretation of the SPECT studies supported the clinical findings (i.e., the visual field defect) by revealing altered regional cerebral blood flow (rCBF) in the appropriate regions of the visual pathway. MR scans in all of the patients, on the other hand, were either normal or disclosed smaller lesions than those detected by SPECT. We conclude that SPECT may reveal altered rCBF in patients with cortical visual impairment of various etiologies, even when MRI studies are normal or nondiagnostic.

  19. Brain SPECT in severs traumatic head injury

    International Nuclear Information System (INIS)

    Beaulieu, F.; Eder, V.; Pottier, J.M.; Baulieu, J.L.; Fournier, P.; Legros, B.; Chiaroni, P.; Dalonneau, M.

    2000-01-01

    The aim of this work was to compare the results of the early brain scintigraphy in traumatic brain injury to the long term neuropsychological behavior. Twenty four patients had an ECD-Tc99m SPECT, within one month after the trauma; scintigraphic abnormalities were evaluated according to a semi-quantitative analysis. The neuropsychological clinical investigation was interpreted by a synthetic approach to evaluate abnormalities related to residual motor deficit, frontal behavior, memory and language disorders. Fourteen patients (58%) had sequela symptoms. SPECT revealed 80 abnormalities and CT scan only 31. Statistical analysis of uptake values showed significantly lower uptake in left basal ganglia and brain stem in patients with sequela memory disorders. We conclude that the brain perfusion scintigraphy is able to detect more lesions than CT and that it could really help to predict the neuropsychological behavior after severe head injury. Traumatology could become in the future a widely accepted indication of perfusion SPECT. (authors)

  20. SPECT and PET in Eating Disorders

    NARCIS (Netherlands)

    van Waarde, Aren; Audenaert, Kurt; Busatto, Geraldo F.; Buchpiguel, Carlos; Dierckx, Rudi; Dierckx, Rudi AJO; Otte, Andreas; de Vries, Erik FJ; van Waarde, Aren; den Boer, Johan A

    2014-01-01

    Medical imaging techniques like PET and SPECT have been applied for investigation of brain function in anorexia and bulimia nervosa. Regional abnormalities have been detected in cerebral blood flow, glucose metabolism, the availability of several neurotransmitter receptors (serotonin 1A and 2A,

  1. Comparison of Tc-99m-sestamibi/(18)FDG DISA SPECT with PET for the detection of viability in patients with coronary artery disease and left ventricular dysfunction

    NARCIS (Netherlands)

    Slart, RHJA; Bax, JJ; de Boer, J; Willemsen, ATM; Mook, Pieter; Oudkerk, M; van der Wall, EE; van Veldhuisen, DJ; Jager, PL

    Purpose: Dual-isotope simultaneous acquisition (DISA) single-photon emission computed tomography ( SPECT) is an attractive technique as it permits assessment of both myocardial glucose metabolism and perfusion within a single session, but few data on its accuracy for the assessment of viability are

  2. The role of Gallium67 scanning in the management of lymphomas

    International Nuclear Information System (INIS)

    Bakir, M.A.; Estifan, N.; Saadieh, A.K.

    1997-09-01

    The clinical usefulness of 6 sup 7 sup G a-citrate as a valuable non-invasive agent for initial staging, the response to treatment assessment, and follow-up of lymphomas, was evaluated. The finding of 65 6 sup 7 sup G a-citrate scans using both imaging modalities planar and single photon emission computed tomography (SPECT) were compared with all clinical information obtained by other diagnostic modalities in 51 treated and untreated patients with lymphomas. 27 patients with Hodgkin's Lymphoma (HL), and 12 patients with Non-Hodgkin's Lymphoma (HL), and 12 patients with Non-Hodgkin's Lymphoma (NHL). Among the patients with HL, there were 18 males and 9 females with a mean age of 27 years. 13 patients had mixed cellularity, 8 had nodular sclerosing type. There were 14 males and 5 females with NHL with a mean age of 48 years. Anterior and posterior images were obtained at 24, 48, and 72 h post injection of 260 MBq (7 mCi) of 6 sup 7 sup G a-citrate using a gamma camera (Siemens orbiter) with a medium energy collimator. Gallium-67-citrate was found to be of great value in staging and evaluating treatment effectiveness as well as early detection of recurrence. (author)

  3. SPECT/CT Fusion in the Diagnosis of Hyperparathyroidism

    International Nuclear Information System (INIS)

    Monzen, Yoshio; Tamura, Akihisa; Okazaki, Hajime; Kurose, Taichi; Kobayashi, Masayuki; Kuraoka, Masatsugu

    2015-01-01

    In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/ computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) were imaged 15 and 120 minutes after the intravenous injection of technetium99m-methoxyisobutylisonitrile ( 99m Tc-MIBI). All patients underwent surgery and 5 parathyroid adenomas and 10 hyperplastic glands were detected. Pathologic findings were correlated with imaging results. The SPECT/CT fusion images were able to detect all parathyroid adenomas even with the greatest axial diameter of 0.6 cm. Planar scintigraphy and SPECT imaging could not detect parathyroid adenomas with an axial diameter of 1.0 to 1.2 cm. Four out of 10 (40%) hyperplastic parathyroid glands were diagnosed, using planar and SPECT imaging and 5 out of 10 (50%) hyperplastic parathyroid glands were localized, using SPECT/CT fusion images. SPECT/CT fusion imaging is a more useful tool for localization of parathyroid lesions, particularly parathyroid adenomas, in comparison with planar and or SPECT imaging

  4. Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection

    International Nuclear Information System (INIS)

    Brankov, Jovan G

    2013-01-01

    The channelized Hotelling observer (CHO) has become a widely used approach for evaluating medical image quality, acting as a surrogate for human observers in early-stage research on assessment and optimization of imaging devices and algorithms. The CHO is typically used to measure lesion detectability. Its popularity stems from experiments showing that the CHO's detection performance can correlate well with that of human observers. In some cases, CHO performance overestimates human performance; to counteract this effect, an internal-noise model is introduced, which allows the CHO to be tuned to match human-observer performance. Typically, this tuning is achieved using example data obtained from human observers. We argue that this internal-noise tuning step is essentially a model training exercise; therefore, just as in supervised learning, it is essential to test the CHO with an internal-noise model on a set of data that is distinct from that used to tune (train) the model. Furthermore, we argue that, if the CHO is to provide useful insights about new imaging algorithms or devices, the test data should reflect such potential differences from the training data; it is not sufficient simply to use new noise realizations of the same imaging method. Motivated by these considerations, the novelty of this paper is the use of new model selection criteria to evaluate ten established internal-noise models, utilizing four different channel models, in a train-test approach. Though not the focus of the paper, a new internal-noise model is also proposed that outperformed the ten established models in the cases tested. The results, using cardiac perfusion SPECT data, show that the proposed train-test approach is necessary, as judged by the newly proposed model selection criteria, to avoid spurious conclusions. The results also demonstrate that, in some models, the optimal internal-noise parameter is very sensitive to the choice of training data; therefore, these models are prone

  5. Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection.

    Science.gov (United States)

    Brankov, Jovan G

    2013-10-21

    The channelized Hotelling observer (CHO) has become a widely used approach for evaluating medical image quality, acting as a surrogate for human observers in early-stage research on assessment and optimization of imaging devices and algorithms. The CHO is typically used to measure lesion detectability. Its popularity stems from experiments showing that the CHO's detection performance can correlate well with that of human observers. In some cases, CHO performance overestimates human performance; to counteract this effect, an internal-noise model is introduced, which allows the CHO to be tuned to match human-observer performance. Typically, this tuning is achieved using example data obtained from human observers. We argue that this internal-noise tuning step is essentially a model training exercise; therefore, just as in supervised learning, it is essential to test the CHO with an internal-noise model on a set of data that is distinct from that used to tune (train) the model. Furthermore, we argue that, if the CHO is to provide useful insights about new imaging algorithms or devices, the test data should reflect such potential differences from the training data; it is not sufficient simply to use new noise realizations of the same imaging method. Motivated by these considerations, the novelty of this paper is the use of new model selection criteria to evaluate ten established internal-noise models, utilizing four different channel models, in a train-test approach. Though not the focus of the paper, a new internal-noise model is also proposed that outperformed the ten established models in the cases tested. The results, using cardiac perfusion SPECT data, show that the proposed train-test approach is necessary, as judged by the newly proposed model selection criteria, to avoid spurious conclusions. The results also demonstrate that, in some models, the optimal internal-noise parameter is very sensitive to the choice of training data; therefore, these models are prone

  6. IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification.

    Science.gov (United States)

    Konishi, Takahiro; Nakajima, Kenichi; Okuda, Koichi; Yoneyama, Hiroto; Matsuo, Shinro; Shibutani, Takayuki; Onoguchi, Masahisa; Kinuya, Seigo

    2017-07-01

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 ( 201 Tl) myocardial perfusion imaging (MPI). A total of 36 patients underwent 1-day 201 Tl adenosine stress-rest MPI. Images were acquired with IQ-SPECT at approximately one-quarter of the standard time of conventional SPECT. Projection data acquired with the IQ-SPECT system were reconstructed via an ordered subset conjugate gradient minimizer method with or without scatter and attenuation correction (SCAC). Projection data obtained using the conventional SPECT were reconstructed via a filtered back projection method without SCAC. The summed stress score (SSS) was calculated using NDBs created by the Japanese Society of Nuclear Medicine working group, and scores were compared between IQ-SPECT and conventional SPECT using the acquisition condition-matched NDBs. The diagnostic performance of the methods for the detection of coronary artery disease was also compared. SSSs were 6.6 ± 8.2 for the conventional SPECT, 6.6 ± 9.4 for IQ-SPECT without SCAC, and 6.5 ± 9.7 for IQ-SPECT with SCAC (p = n.s. for each comparison). The SSS showed a strong positive correlation between conventional SPECT and IQ-SPECT (r = 0.921 and p IQ-SPECT with and without SCAC was also good (r = 0.907 and p IQ-SPECT without SCAC; and 88.5, 86.8, and 87.3%, respectively, for IQ-SPECT with SCAC, respectively. The area under the curve obtained via receiver operating characteristic analysis were 0.77, 0.80, and 0.86 for conventional SPECT, IQ-SPECT without SCAC, and IQ-SPECT with SCAC, respectively (p = n.s. for each comparison). When appropriate NDBs were used, the diagnostic performance of 201 Tl IQ-SPECT

  7. Electrospun Gallium Nitride Nanofibers

    International Nuclear Information System (INIS)

    Melendez, Anamaris; Morales, Kristle; Ramos, Idalia; Campo, Eva; Santiago, Jorge J.

    2009-01-01

    The high thermal conductivity and wide bandgap of gallium nitride (GaN) are desirable characteristics in optoelectronics and sensing applications. In comparison to thin films and powders, in the nanofiber morphology the sensitivity of GaN is expected to increase as the exposed area (proportional to the length) increases. In this work we present electrospinning as a novel technique in the fabrication of GaN nanofibers. Electrospinning, invented in the 1930s, is a simple, inexpensive, and rapid technique to produce microscopically long ultrafine fibers. GaN nanofibers are produced using gallium nitrate and dimethyl-acetamide as precursors. After electrospinning, thermal decomposition under an inert atmosphere is used to pyrolyze the polymer. To complete the preparation, the nanofibers are sintered in a tube furnace under a NH 3 flow. Both scanning electron microscopy and profilometry show that the process produces continuous and uniform fibers with diameters ranging from 20 to a few hundred nanometers, and lengths of up to a few centimeters. X-ray diffraction (XRD) analysis shows the development of GaN nanofibers with hexagonal wurtzite structure. Future work includes additional characterization using transmission electron microscopy and XRD to understand the role of precursors and nitridation in nanofiber synthesis, and the use of single nanofibers for the construction of optical and gas sensing devices.

  8. Lattice Dynamics of Gallium Phosphide

    International Nuclear Information System (INIS)

    Yarnell, J.L.; Warren, J.L.; Wenzel, R.G.; Dean, P.J.

    1968-01-01

    Dispersion curves for phonons propagating in the [100], [110], and [111] directions in gallium phosphide have been measured using a triple-axis neutron diffraction spectrometer operating in the constant-Q mode. The sample was a pseudo-single crystal which was prepared by gluing together 36 single crystal plates of gallium phosphide 1 to 2.5 cm in diameter and ∼0.07 cm thick. The plates were grown epitaxially on substrates of gallium arsenide or gallium phosphide, and aligned individually by neutron diffraction. Rocking curves for eight reflections symmetrically distributed in the plane of the experiment had full widths at half maximum in the range 0.52° - 0.58° and were approximately Gaussian in shape. Gallium phosphide crystallizes in the zinc blende structure. A group theoretic analysis of the lattice dynamics of this structure and a shell model fit to the measured dispersion curves are presented. Various optical properties of gallium phosphide are discussed in terms of the phonon dispersion curves. In particular, the phonons which assist indirect electronic transitions are identified as those at the zone boundary in the [100] direction (symmetry point X) in agreement with theoretical and experimental indications that the extrema of the conduction and valence bands are at X and Γ (center of the zone), respectively. The LO branches lie above the TO branches throughout the Brillouin zone in contradiction to the predictions of Keyes and Mitra. The shell model fit indicates that the charge on the gallium atom is negative. (author)

  9. Gallium interstitial contributions to diffusion in gallium arsenide

    Science.gov (United States)

    Schick, Joseph T.; Morgan, Caroline G.

    2011-09-01

    A new diffusion path is identified for gallium interstitials, which involves lower barriers than the barriers for previously identified diffusion paths [K. Levasseur-Smith and N. Mousseau, J. Appl. Phys. 103, 113502 (2008), P. A. Schultz and O. A. von Lilienfeld, Modelling and Simulation in Materials Science and Engineering 17, 084007 (2009)] for the charge states which dominate diffusion over most of the available range of Fermi energies. This path passes through the ⟨110⟩ gallium-gallium split interstitial configuration, and has a particularly low diffusion barrier of 0.35 eV for diffusion in the neutral charge state. As a part of this work, the character of the charge states for the gallium interstitials which are most important for diffusion is investigated, and it is shown that the last electron bound to the neutral interstitial occupies a shallow hydrogenic bound state composed of conduction band states for the hexagonal interstitial and both tetrahedral interstitials. How to properly account for the contributions of such interstitials is discussed for density-functional calculations with a k-point mesh not including the conduction band edge point. Diffusion barriers for gallium interstitials are calculated in all the charge states which can be important for a Fermi level anywhere in the gap, q = 0, +1, +2, and +3, for diffusion via the ⟨110⟩ gallium-gallium split interstitial configuration and via the hexagonal interstitial configuration. The lowest activation enthalpies over most of the available range of Fermi energies are found to correspond to diffusion in the neutral or singly positive state via the ⟨110⟩ gallium-gallium split interstitial configuration. It is shown that several different charge states and diffusion paths contribute significantly for Fermi levels within 0.2 eV above the valence band edge, which may help to explain some of the difficulties [H. Bracht and S. Brotzmann, Phys. Rev. B 71, 115216 (2005)] which have been

  10. Fabrication of Aluminum Gallium Nitride/Gallium Nitride MESFET And It's Applications in Biosensing

    Science.gov (United States)

    Alur, Siddharth

    Gallium Nitride has been researched extensively for the past three decades for its application in Light Emitting Diodes (LED's), power devices and UV photodetectors. With the recent developments in crystal growth technology and the ability to control the doping there has been an increased interest in heterostructures formed between Gallium nitride and it's alloy Aluminium Gallium Nitride. These heterostructures due to the combined effect of spontaneous and piezoelectric effect can form a high density and a high mobility electron gas channel without any intentional doping. This high density electron gas makes these heterostructures ideal to be used as sensors. Gallium Nitride is also chemically very stable. Detection of biomolecules in a fast and reliable manner is very important in the areas of food safety and medical research. For biomolecular detection it is paramount to have a robust binding of the probes on the sensor surface. Therefore, in this dissertation, the fabrication and application of the AlGaN/GaN heterostructures as biological sensors for the detection of DNA and Organophosphate hydrolase enzyme is discussed. In order to use these AlGaN/GaN heterostructures as biological sensors capable of working in a liquid environment photodefinable polydimethyl-siloxane is used as an encapsulant. The immobilization conditions for a robust binding of thiolated DNA and the catalytic receptor enzyme organophosphate hydrolase on gold surfaces is developed with the help of X-ray photoelectron spectroscopy. DNA and OPH are detected by measuring the change in the drain current of the device as a function of time.

  11. Brain SPECT in childhood

    International Nuclear Information System (INIS)

    Tranquart, F.; Saliba, E.; Prunier, C.; Baulieu, F.; Besnard, J.C.; Guilloteau, D.; Baulieu, J.L.

    2001-01-01

    The modalities and the indications of perfusion and neurotransmission SPECT in childhood are presented. The perfusion as well as neurotransmission tracers have not yet authorization for use in children; they have to be used by prescription of magistral preparation or in research protocols. The radioprotection rules have to be strictly respected. The most frequent indication of perfusion SPECT is pharmacologically resistant epilepsy; the ictal SPECT before surgery allows the localization of the epileptogenic focus. Other indications are relevant in the prognosis of neonatal anoxia and encephalitis. In psychiatric disorders, especially in autism, the interest is the physiopathological approach of the brain dysfunctions. The neurotransmission SPECT is emerging as a consequence of the development of new radiotracer, as the dopaminergic system ligands. The decrease of the dopamine D2 receptors in the striatum can be imaged and quantified in the neonate. The lesions of dopamine system seem to be a consequence of the neonatal hypoxia-ischemia and it is predictive of motor sequelae. Brain SPECT should become a routine examination in child neurologic and psychiatric disorders. (authors)

  12. HM-PAO SPECT in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Cordes, M.; Rummeny, E.; Reissmann, M.; Fox, K.; Panitz, N.; Pfannenstiel, P.

    1987-01-01

    Single photon emission computed tomography (SPECT) after injection of 99m-Tc-HM-PAO was used to examine 34 patients whose clinical findings could not exclude a cerebrovascular disease. In all patients an X-ray computed tomography examination was inconclusive for the clinical-neurological findings. The regional cerebral bloodflow was pathologically disturbed in 10 of 34 patients in the HM-PAO SPECT examination. The detection of the regional cerebral bloodflow with HM-PAO SPECT is helpful in the diagnosis of cerebrovascular disease. (orig.) [de

  13. A novel statistical analysis method to improve the detection of hepatic foci of {sup 111}In-octreotide in SPECT/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Magnander, Tobias [Department of Radiation Physics, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden); Wikberg, E. [Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden); Svensson, J. [Department of Oncology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Gjertsson, P. [Department of Clinical Physiology, The Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Wängberg, B. [Department of Surgery, The Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Båth, M.; Bernhardt, Peter [Department of Radiation Physics, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Gothenburg (Sweden); Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg (Sweden)

    2016-01-19

    Low uptake ratios, high noise, poor resolution, and low contrast all combine to make the detection of neuroendocrine liver tumours by {sup 111}In-octreotide single photon emission tomography (SPECT) imaging a challenge. The aim of this study was to develop a segmentation analysis method that could improve the accuracy of hepatic neuroendocrine tumour detection. Our novel segmentation was benchmarked by a retrospective analysis of patients categorized as either {sup 111}In-octreotide positive ({sup 111}In-octreotide(+)) or {sup 111}In-octreotide negative ({sup 111}In-octreotide(−)) for liver tumours. Following a 3-year follow-up period, involving multiple imaging modalities, we further segregated {sup 111}In-octreotide-negative patients into two groups: one with no confirmed liver tumours ({sup 111}In-octreotide(−)/radtech(−)) and the other, now diagnosed with liver tumours ({sup 111}In-octreotide(−)/radtech(+)). We retrospectively applied our segmentation analysis to see if it could have detected these previously missed tumours using {sup 111}In-octreotide. Our methodology subdivided the liver and determined normalized numbers of uptake foci (nNUF), at various threshold values, using a connected-component labelling algorithm. Plots of nNUF against the threshold index (ThI) were generated. ThI was defined as follows: ThI = (c{sub max} − c{sub thr})/c{sub max}, where c{sub max} is the maximal threshold value for obtaining at least one, two voxel sized, uptake focus; c{sub thr} is the voxel threshold value. The maximal divergence between the nNUF values for {sup 111}In-octreotide(−)/radtech(−), and {sup 111}In-octreotide(+) livers, was used as the optimal nNUF value for tumour detection. We also corrected for any influence of the mean activity concentration on ThI. The nNUF versus ThI method (nNUFTI) was then used to reanalyze the {sup 111}In-octreotide(−)/radtech(−) and {sup 111}In-octreotide(−)/radtech(+) groups. Of a total of 53 {sup 111}In

  14. Prospects for recovering gallium from extracted coal

    Energy Technology Data Exchange (ETDEWEB)

    Ratynskiy, V M; Reznik, A M; Zekel, L A; Zharov, Yu N

    1979-01-01

    The authors conducted research in order to establish the physical-chemical mechanisms governing the behavior of rare and dispersed elements within the thermal treatment processes used to treat coal and enrichment waste. New means are proposed for obtaining concentrations of gallium. These methods are under consideration primarily for the isolation of gallium as a by-product during the production of aggloporite from coal waste. The authors examine in detail the results of research dealing with the transfer of gallium compounds in a solution, the extraction of gallium from solutions, the separation of impurities from gallium, and the isolation of gallium from extract. Utilizing research results, the authors determine the expenditure coefficient and costs for additives used to extract gallium from waste by-products. The realization of this gallium extraction process from those products having the best prospects for gallium content resulted in economic savings.

  15. SPECT in psychiatry

    International Nuclear Information System (INIS)

    Kasper, S.; Gruenwald, F.; Walter, H.; Klemm, E.; Podreka, I.; Biersack, H.J.

    1994-01-01

    In the last fifteen years different attempts have been undertaken to understand the biological basis of major psychiatric disorders. One important tool to determine patterns of brain dysfunction is single emission computed tomography (SPECT). Whereas SPECT investigations are already a valuable diagnostic instrument for the diagnosis of dementia of the Alzheimer Type (DAT) there have not been consistent findings that can be referred to as specific for any other particular psychiatric diagnostic entity. Nevertheless, SPECT studies have been able to demonstrate evidence of brain dysfunction in patients with schizophrenia, depression, anxiety disorders, and substance abuse in which other methods showed no clear abnormality of brain function. Our manuscript reviews the data which are currently available in the literature and stresses the need for further studies, especially for prediction and monitoring psychiatric treatment modalities. (orig.) [de

  16. Applications of cerebral SPECT

    Energy Technology Data Exchange (ETDEWEB)

    McArthur, C., E-mail: claire.mcarthur@nhs.net [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom); Jampana, R.; Patterson, J.; Hadley, D. [Department of Neuroradiology, Institute of Neurological Sciences, Glasgow (United Kingdom)

    2011-07-15

    Single-photon emission computed tomography (SPECT) can provide three-dimensional functional images of the brain following the injection of one of a series of radiopharmaceuticals that crosses the blood-brain barrier and distributes according to cerebral perfusion, neurotransmitter, or cell density. Applications include differentiating between the dementias, evaluating cerebrovascular disease, preoperative localization of epileptogenic foci, diagnosing movement disorders, and evaluation of intracerebral tumours, while also proving a useful research tool. Unlike positronemission tomography (PET), SPECT imaging is widely available and can be performed in any department that has access to a rotating gamma camera. The purpose of this review is to demonstrate the utility of cerebral SPECT and increase awareness of its role in the investigation of neurological and psychiatric disorders.

  17. Gallium Safety in the Laboratory

    International Nuclear Information System (INIS)

    Cadwallader, L.C.

    2003-01-01

    A university laboratory experiment for the US Department of Energy magnetic fusion research program required a simulant for liquid lithium. The simulant choices were narrowed to liquid gallium and galinstan (Ga-In-Sn) alloy. Safety information on liquid gallium and galinstan were compiled, and the choice was made to use galinstan. A laboratory safety walkthrough was performed in the fall of 2002 to support the galinstan experiment. The experiment has been operating successfully since early 2002

  18. ASSESSMENT OF GALLIUM OXIDE TECHNOLOGY

    Science.gov (United States)

    2017-08-01

    AFRL-RY-WP-TR-2017-0167 ASSESSMENT OF GALLIUM OXIDE TECHNOLOGY Burhan Bayraktaroglu Devices for Sensing Branch Aerospace...TITLE AND SUBTITLE ASSESSMENT OF GALLIUM OXIDE TECHNOLOGY 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER N/A 6...report summarizes the current status of the Ga2O3 technology based on published results on theoretical electronic structure, materials growth, and

  19. High-resolution SPECT for small-animal imaging

    International Nuclear Information System (INIS)

    Qi Yujin

    2006-01-01

    This article presents a brief overview of the development of high-resolution SPECT for small-animal imaging. A pinhole collimator has been used for high-resolution animal SPECT to provide better spatial resolution and detection efficiency in comparison with a parallel-hole collimator. The theory of imaging characteristics of the pinhole collimator is presented and the designs of the pinhole aperture are discussed. The detector technologies used for the development of small-animal SPECT and the recent advances are presented. The evolving trend of small-animal SPECT is toward a multi-pinhole and a multi-detector system to obtain a high resolution and also a high detection efficiency. (authors)

  20. Usefulness of brain SPECT

    International Nuclear Information System (INIS)

    Raynaud, C.; Rancurel, G.; Kieffer, E.; Ricard, S.; Askienazy, S.; Moretti, J.L.; Bourdoiseau, M.; Rapin, J.; Soussaline, F.

    1983-01-01

    Brain SPECT was not effectively exploited until I-123 isopropyl amphetamine (IAMP), indicator able to penetrate the blood brain barrier, became available. Although the experience of research teams working with IAMP is quite restricted due to the high cost of the indicator, some applications now appear to be worth the cost and in some cases provide data which cannot be obtained with routine techniques, especially in cerebrovascular patients, in epilepsy and some cases of tumor. Brain SPECT appears as an atraumatic test which is useful to establish a functional evaluation of the cerebral parenchyma, and which is a complement to arteriography, X-ray scan and regional cerebral blood flow measurement

  1. Brain spect imaging

    International Nuclear Information System (INIS)

    Lee, R.G.L.; Hill, T.C.; Holman, B.L.

    1989-01-01

    This paper discusses how the rapid development of single-photon radiopharmaceuticals has given new life to tomographic brain imaging in nuclear medicine. Further developments in radiopharmaceuticals and refinements in neuro-SPECT (single-photon emission computed tomography) instrumentation should help to reinstate brain scintigraphy as an important part of neurologic diagnosis. SPECT of the brain evolved from experimentation using prototype instrumentation during the early 1960s. Although tomographic studies provided superior diagnostic accuracy when compared to planar techniques, the arrival of X-ray CT of the head resulted in the rapid demise of technetium brain imaging

  2. Structural variations in nanosized confined gallium

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kai [Department of Physics, National Cheng Kung University, Tainan 70101, Taiwan (China); Tien Cheng [Department of Physics, National Cheng Kung University, Tainan 70101, Taiwan (China)] [Center for Micro/Nano Science of Technology, National Cheng Kung University, Tainan 70101, Taiwan, ROC (China); Charnaya, E.V., E-mail: charnaya@live.co [Department of Physics, National Cheng Kung University, Tainan 70101, Taiwan (China)] [Institute of Physics, St. Petersburg State University, St. Petersburg, Petrodvorets 198504 (Russian Federation); Sheu, Hwo-Shuenn [National Synchrotron Radiation Research Center, Hsinchu 30076, Taiwan (China); Kumzerov, Yu.A. [A.F. Ioffe Physico-Technical Institute RAS, St. Petersburg, 194021 (Russian Federation)

    2010-03-29

    The complex crystalline structure of gallium under nanoconfinement was revealed by synchrotron radiation x-ray powder diffraction. Nanoconfinement was shown to stabilize delta-Ga which is metastable in bulk. Two new gallium phases named iota- and kappa-Ga were found upon cooling below room temperature. These crystalline modifications were stable and coexisted with known gallium phases. Correlations between confined gallium particle shapes and emergence of particular crystalline phases were observed. Melting and freezing temperatures for different gallium phases were obtained. Remarkable supercooling of liquid gallium was seen in 3.5 nm pores.

  3. Comparison of {sup 99m}Tc-HMPAO SPECT and MRI after Acute and Subacute Closed-Head Injury

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Won Jong; Lee, Sang Hoon; Sohn, Hyung Sun; Lee, Han Jin; Park, Jeong Mi; Chung, Soo Kyo; Kim, Choon Yul; Bahk, Yong Whee; Shin, Kyung Sub [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1994-10-15

    The purpose of this study was to compare {sup 99m}Tc-HMPAO SPECT with MRI after acute and subacute closed head injury. There were thirty two focal lesions in all cases of these, Fifteen lesions(47%) were seen on both MRI and SPECT. Fourteen lesions(44%) were seen only on MRI. Three lesions(9%) were seen only on SPECT. Of the 14 lesions seen only on MRl, one was epidural hematoma, two were subdural hematoma, three were subdural hygroma, one was intracerebral hematoma, four were contusion, and three were diffuse axonal injuries. SPECT detected 52% of the focal lesions found on MRI. For the detection of lesions, MRl was superior to SPECT in fourteen cases, while SPECT was superior to MRI in three cases. In conclusion, there was a tendency that detection rate of the traumatic lesions was higher on MRI, but the SPECT could delineate more wide extent of lesion.

  4. Enhanced Diagnosis of Coronary Artery Disease in Women by Dobutamine Thallium-201 ST-Segment/Heart Rate Slope and Thallium-201 Myocardial SPECT

    Directory of Open Access Journals (Sweden)

    Dong-Feng Yeih

    2007-10-01

    Conclusion: Dobutamine ST/HR slope is less sensitive and less accurate than Tl-201 SPECT for detecting CAD in women. However, it adds diagnostic benefit to Tl-201 SPECT with only a little extra calculation.

  5. Quantitative assessment of 201TlCl myocardial SPECT

    International Nuclear Information System (INIS)

    Uehara, Toshiisa

    1987-01-01

    Clinical evaluation of the quantitative analysis of Tl-201 myocardial tomography by SPECT (Single Photon Emission Computed Tomography) was performed in comparison with visual evaluation. The method of quantitative analysis has been already reported in our previous paper. In this study, the program of re-standardization in the case of lateral myocardial infarction was added. This program was useful mainly for the evaluation of lesions in the left circumflex coronary artery. Regarding the degree of diagnostic accuracy of myocardial infarction in general, quantitative evaluation of myocardial SPECT images was highest followed by visual evaluation of myocardial SPECT images, and visual evaluation of myocardial planar images. However, in the case of anterior myocardial infarction, visual evaluation of myocardial SPECT images has almost the same detectability as quantitative evaluation of myocardial SPECT images. In the case of infero-posterior myocardial infarction, quantitative evaluation was superior to visual evaluation. As for specificity, quantitative evaluation of SPECT images was slightly inferior to visual evaluation of SPECT images. An infarction map was made by quantitative analysis and this enabled us to determine the infarction site, extent and degree according to easily recognizable patterns. As a result, the responsible coronary artery lesion could be inferred correctly and the calculated infarction score could be correlated with the residual left ventricular function after myocardial infarction. (author)

  6. Anatomically standardized statistical mapping of 123I-IMP SPECT in brain tumors

    International Nuclear Information System (INIS)

    Shibata, Yasushi; Akimoto, Manabu; Matsushita, Akira; Yamamoto, Tetsuya; Takano, Shingo; Matsumura, Akira

    2010-01-01

    123 I-iodoamphetamine Single Photon Emission Computed Tomography (IMP SPECT) is used to evaluate cerebral blood flow. However, application of IMP SPECT to patients with brain tumors has been rarely reported. Primary central nervous system lymphoma (PCNSL) is a rare tumor that shows delayed IMP uptake. The relatively low spatial resolution of SPECT is a clinical problem in diagnosing brain tumors. We examined anatomically standardized statistical mapping of IMP SPECT in patients with brain lesions. This study included 49 IMP SPECT images for 49 patients with brain lesions: 20 PCNSL, 1 Burkitt's lymphoma, 14 glioma, 4 other tumor, 7 inflammatory disease and 3 without any pathological diagnosis but a clinical diagnosis of PCNSL. After intravenous injection of 222 MBq of 123 I-IMP, early (15 minutes) and delayed (4 hours) images were acquired using a multi-detector SPECT machine. All SPECT data were transferred to a newly developed software program iNeurostat+ (Nihon Medi-physics). SPECT data were anatomically standardized on normal brain images. Regions of increased uptake of IMP were statistically mapped on the tomographic images of normal brain. Eighteen patients showed high uptake in the delayed IMP SPECT images (16 PCNSL, 2 unknown). Other tumor or diseases did not show high uptake of delayed IMP SPECT, so there were no false positives. Four patients with pathologically proven PCNSL showed no uptake in original IMP SPECT. These tumors were too small to detect in IMP SPECT. However, statistical mapping revealed IMP uptake in 18 of 20 pathologically verified PCNSL patients. A heterogeneous IMP uptake was seen in homogenous tumors in MRI. For patients with a hot IMP uptake, statistical mapping showed clearer uptake. IMP SPECT is a sensitive test to diagnose of PCNSL, although it produced false negative results for small posterior fossa tumor. Anatomically standardized statistical mapping is therefore considered to be a useful method for improving the diagnostic

  7. Gallium scan in recurrent Hodgkin's disease in children

    International Nuclear Information System (INIS)

    Yeh, S.D.; Benua, R.S.; Tan, C.T.

    1979-01-01

    In 18 of 88 children with biopsy proven and previously untreated Hodgkin's disease, recurrence developed during a period from four to 53 months after therapy (median period, 22 months). In 16 patients in whom gallium scans were performed, 21 positive gallium scans were obtained during 26 episodes of recurrence. Abnormalities were noted in half of them during a period from one to 10 months prior to physical, laboratory, radiographic or histologic confirmation of recurrence (median period about 5 months). We have concluded that the gallium scan is very useful in initial workup and is sensitive in detecting early recurrence in children with Hodgkin's disease. Such scans are indicated when there is clinical suspicion of recurrence, when other modalities are unavailable or when the results of other studies are equivocal

  8. Ventilation-perfused studies using SPECT

    International Nuclear Information System (INIS)

    Zwijnenburg, A.

    1989-01-01

    A method for the quantitative analysis of ventilation-perfusion SPECT studies is decribed and an effort is made to evaluate its usefullness. The technical details of the emthod are described. In the the transaxial reconstructions of the tomographic studies the contour of the lungs is detected and regional values of lung volume, ventilation, perfusion and ventilation-perfusion ratios are calculated. The method is operator independent. The lung volume calculations from the SPECT studies are validated by comparing them with lung volume measurements using the helium dilution technique. A good correlation (r=0.91) was found between the two volumes. SPECT volume was greater than the volume measured with helium dilution, which was attributed to non-gas-containing structures in the. lungs. The use of ventilation-perfusion ratio SPECT is described to evaluate the effect of ionizing radiation on the lungs in patients treated with mantle field irradiation for Hodgkin's disease. Perfusion changes appear as early as 2 months after the start of irradiation. Ventilation changes appear later and relatively minor. No changes are seen outside the radiation portals. The ventilation-perfusion inequality in pulmonary sarcoidosis is treated. It is suggested that the decrease D LCO in these patients may be partly due to an even distribution of ventilation perfusion ratios. An effort is made to establish the properties of a new tracer used for the assessment of the metabolic function of the pulmonary endothelium. The lung uptake of I-123 IMP mimics the distribution of a perfusion tracer and it is suggested that this tracer may be useful for the early detection of pulmonary vascular damage, even when blood flow is still intact. Some aspects of the use of Kr-81m as a ventilation tracer are discussed as well as the effect of noise on Kr-81m SPECT reconstructions. (author). 146 refs.; 39 figs.; 8 tabs

  9. Clinical evaluation of 123I-IMP SPECT in patients with various neurological diseases

    International Nuclear Information System (INIS)

    Yoneda, Naoto

    1993-01-01

    Single photon emission computed tomography with N-isopropyl-p-[ 123 I] iodoamphetamine ( 123 I-IMP SPECT) was performed in 57 patients with various neurological disease, and compared with the findings of brain CT, MRI, and EEG. The author also evaluated the relationship between the findings on 123 I-IMP SPECT and the condition of the control of the attack after treatment with antiepileptic drugs in idiopathic epileptic patients. Abnormality of accumulation of 123 I-IMP SPECT was observed in 62.3% of all cases. Focal abnormality was detected in 28.3% of all cases by brain CT and 54.1% by MRI. The detectability of focal abnormality in brain CT and MRI was found to be lower than that of 123 I-TMP SPECT. There was very little significance in detectability between 123 I-IMP SPECT and EEG. But it infers that 123 I-IMP SPECT can detect the subictal state in epileptic patients. One comparative study of the relationship between the findings on 123 I-IMP SPECT and the condition of the control of the attack by antiepileptic drugs in patients with idiopathic epilepsy, abnormality of 123 I-IMP SPECT findings was found to be higher in patients who were not controlled sufficiently than in patients who were controlled sufficiently, and a significant difference is found by X 2 test. 123 I-IMP SPECT is useful for the evaluation of treatment in patients with epilepsy. (author)

  10. SPECT imaging in evaluating extent of malignant external otitis: case report

    International Nuclear Information System (INIS)

    English, R.J.; Tu'Meh, S.S.; Piwnica-Worms, D.; Holman, B.L.

    1987-01-01

    Otitis externa, a benign inflammatory process of the external auditory canal, is general responsive to local therapy. Some patients however, develop a less controllable disease leading to chondritis and osteomyelitis of the base of the skull. The direct invasive characteristic of the disease has led to the descriptive term malignant external otitis (MEO), more appropriately called necrotizing or invasive external otitis. Malignant external otitis is caused by an aggressive pseudomonas or proteus infection that almost exclusively occurs in elderly diabetic patients. The primary imaging modalities previously used in the diagnosis and evaluation of MEO were standard planar scintigraphic techniques with technetium-99M (/sup 99m/Tc) bone agents and gallium-67 ( 67 Ga), and pluridirectional tomography. The advent of high resolution computed tomography (CT) effectively allowed demonstration of the soft tissue extension and bone destruction associated with MEO, but still suffered from the low sensitivity constraints of all radiographic techniques in determining early inflammatory bone involvement. Recent work suggests that scintigraphic detection of MEO with /sup 99m/Tc-MDP and 67 Ga, combined with the cross-sectional resolution of single photon emission computed tomography (SPECT) may be of value in planning treatment of this inflammatory condition

  11. Radiopharmaceuticals for brain - SPECT

    International Nuclear Information System (INIS)

    Moretti, J.L.

    1992-01-01

    Perfusion tracers for brain SPECT imaging suitable for regional cerebral blood flow measurement and regional cerebral blood volume determination, with respect to their ability to pass the blood-brain-barrier, are described. Problems related t the use of specific radiotracers to map receptors distribution in the brain are also discussed in this lecture. 9 figs, 6 tabs

  12. SPECT and PET Serve as Molecular Imaging Techniques and in Vivo Biomarkers for Brain Metastases

    Science.gov (United States)

    Palumbo, Barbara; Buresta, Tommaso; Nuvoli, Susanna; Spanu, Angela; Schillaci, Orazio; Fravolini, Mario Luca; Palumbo, Isabella

    2014-01-01

    Nuclear medicine techniques (single photon emission computerized tomography, SPECT, and positron emission tomography, PET) represent molecular imaging tools, able to provide in vivo biomarkers of different diseases. To investigate brain tumours and metastases many different radiopharmaceuticals imaged by SPECT and PET can be used. In this review the main and most promising radiopharmaceuticals available to detect brain metastases are reported. Furthermore the diagnostic contribution of the combination of SPECT and PET data with radiological findings (magnetic resonance imaging, MRI) is discussed. PMID:24897023

  13. Superconductivity and structure of gallium under nanoconfinement

    Energy Technology Data Exchange (ETDEWEB)

    Charnaya, E V; Tien, Cheng; Lee, Min Kai [Department of Physics, National Cheng Kung University, Tainan 70101, Taiwan (China); Kumzerov, Yu A [A F Ioffe Physico-Technical Institute RAS, St Petersburg, 194021 (Russian Federation)

    2009-11-11

    Superconductivity and crystalline structure were studied for two nanocomposites consisting of gallium loaded porous glasses with different pore sizes. The superconducting transition temperatures were found to differ from those in known bulk gallium modifications. The transition temperatures 7.1 and 6.7 K were ascribed to two new confined gallium structures, iota- and kappa-Ga, observed by synchrotron radiation x-ray powder diffraction. The evolution of superconductivity on decreasing the pore filling with gallium was also studied.

  14. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    International Nuclear Information System (INIS)

    Lacic, K.; Bokulic, T.; Lukac, J.; Dakovic, N.; Kusic, Z.

    1994-01-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more 'hot' and less 'cold' lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more 'hot' lesions than 4-6 hours SPECT. At the same time the number of 'cold' lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author)

  15. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Lacic, K; Bokulic, T; Lukac, J; Dakovic, N; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine

    1994-10-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more `hot` and less `cold` lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more `hot` lesions than 4-6 hours SPECT. At the same time the number of `cold` lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author).

  16. Brain lesion analysis using three-dimensional SPECT imaging

    International Nuclear Information System (INIS)

    Shibata, Iekado; Onagi, Atsuo; Kuroki, Takao

    1995-01-01

    A three-headed gamma camera (PRISM 3000) is capable to scan the protocol of early dynamic SPECT and to analyze two radioisotopes at the same time. We have framed three-dimensional brain SPECT images for several brain diseases by using the Application Visualization System (AVS). We carried out volume measurements in brain tumors and/or AVMs by applying this methodology. Thallium-201 and/or 123I-IMP were used for brain SPECT imaging. The dynamic scan protocol was changed in accordance with the given disease. The protocol for brain tumors was derived from a preliminary comparative study with thallium-201 and 123I-IMP that had suggested a disparity in the detection of brain tumors and the differentiation between tumor tissue and normal brain. The three-dimension SPECT image represented the brain tumor or AVM in a striking fashion, and the changes with respect to tumor or AVM after radiosurgery or embolization were understood readily. (author)

  17. SPECT/CT in the Diagnosis of Skull Base Osteomyelitis

    International Nuclear Information System (INIS)

    Damle, Nishikant Avinash; Kumar, Rakesh; Kumar, Praveen; Jaganthan, Sriram; Patnecha, Manish; Bal, Chandrasekhar; Bandopadhyaya, Gurupad; Malhotra, Arun

    2011-01-01

    Skull base osteomyelitis is a potentially fatal disease. We demonstrate here the utility of SPECT/CT in diagnosing this entity, which was not obvious on a planar bone scan. A 99mT c MDP bone scan with SPECT/CT was carried out on a patient with clinically suspected skull base osteomyelitis. Findings were correlated with contrast enhanced CT (CECT) and MRI. Planar images were equivocal, but SPECT/CT showed intense uptake in the body of sphenoid and petrous temporal bone as well as the atlas corresponding to irregular bone destruction on CT and MRI. These findings indicate that SPECT/CT may have an additional role beyond planar imaging in the detection of skull base osteomyelitis.

  18. Hydrogen inventory in gallium

    International Nuclear Information System (INIS)

    Mazayev, S.N.; Prokofiev, Yu.G.

    1994-01-01

    Investigations of hydrogen inventory in gallium (99.9%) were carried out after saturation both from molecular phase and from glow discharge plasma at room temperature, 370 and 520 K. Saturation took place during 3000 s under hydrogen pressure of 20 Pa, and ion flux was about 1x10 15 ions/cm 2 s with an energy about 400 eV during discharge. Hydrogen concentration in Ga at room temperature and that for 370 K by the saturation from gaseous phase was (2-3)x10 14 cm -3 Pa -1/2 . Hydrogen concentration at temperature 520 K increased by five times. Inventory at room temperature for irradiation from discharge was 7x10 16 cm -3 at the dose about 3x10 18 ions/cm 2 . It was more than inventory at temperature 520 K by four times and more than maximum inventory from gaseous phase at 520 K by a factor of 10. Inventory increased when temperature decreased. Diffusion coefficient D=0.003 exp(-2300/RT) cm 2 /s, was estimated from temperature dependence. ((orig.))

  19. Effect of STA-MCA bypass based on the motor activation SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    1999-07-01

    The effect of STA-MCA bypass for ischemic cerebrovascular diseases (CVDs) on pure motor function using motor activation SPECT was evaluated and analyzed, and this effect with the resting cerebral blood flow and reserved capacity was compared. Motor activation SPECT were carried out on 22 cases with STA-MCA bypass for symptomatic ischemic CVDs. All motors activation SPECT using the finger opposition task on the affected side were performed before bypass, at 1 month, and 3 months after the bypass. Visual inspection was used to determine whether the result of the motor activation SPECT was as negative or positive. The activated region was detected anatomically precisely by superimposing the SPECT on the MRI. Before this study, the same examination was performed on normal controls. In controls, 91% showed the activated area on the sensorimotor cortex after the finger opposition tasks. Before bypass, the resting SPECT revealed reduction of cerebral blood flow (CBF) on the affected side in all cases. All cases also showed a disturbed response to acetazolamide (ACZ). Nine cases were positive in the motor activation SPECT. One month after bypass, the resting CBF increased in 11 cases. Seven showed preoperative positive motor activation. Fifteen cases were positive in the motor activation SPECT. Three months after bypass, 20 cases showed improvement in the resting CBF, and 19 cases were positive in the motor activation SPECT. Ten cases were negative in the preoperative motor activation SPECT. At one month after surgery, ACZ activation SPECT was performed in 12 cases. Five showed improvement of the response to ACZ. At 3 months after surgery, 8 of 12 cases treated with ACZ activation SPECT showed improved response to ACZ. In most of the cases, improved response to ACZ could be seen after response to motor activation improved. STA-MCA bypass is useful not only for resting CBF but also for pure motor function based on motor activation SPECT. (K.H.)

  20. Effect of STA-MCA bypass based on the motor activation SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Uranishi, Ryunosuke; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    1999-01-01

    The effect of STA-MCA bypass for ischemic cerebrovascular diseases (CVDs) on pure motor function using motor activation SPECT was evaluated and analyzed, and this effect with the resting cerebral blood flow and reserved capacity was compared. Motor activation SPECT were carried out on 22 cases with STA-MCA bypass for symptomatic ischemic CVDs. All motors activation SPECT using the finger opposition task on the affected side were performed before bypass, at 1 month, and 3 months after the bypass. Visual inspection was used to determine whether the result of the motor activation SPECT was as negative or positive. The activated region was detected anatomically precisely by superimposing the SPECT on the MRI. Before this study, the same examination was performed on normal controls. In controls, 91% showed the activated area on the sensorimotor cortex after the finger opposition tasks. Before bypass, the resting SPECT revealed reduction of cerebral blood flow (CBF) on the affected side in all cases. All cases also showed a disturbed response to acetazolamide (ACZ). Nine cases were positive in the motor activation SPECT. One month after bypass, the resting CBF increased in 11 cases. Seven showed preoperative positive motor activation. Fifteen cases were positive in the motor activation SPECT. Three months after bypass, 20 cases showed improvement in the resting CBF, and 19 cases were positive in the motor activation SPECT. Ten cases were negative in the preoperative motor activation SPECT. At one month after surgery, ACZ activation SPECT was performed in 12 cases. Five showed improvement of the response to ACZ. At 3 months after surgery, 8 of 12 cases treated with ACZ activation SPECT showed improved response to ACZ. In most of the cases, improved response to ACZ could be seen after response to motor activation improved. STA-MCA bypass is useful not only for resting CBF but also for pure motor function based on motor activation SPECT. (K.H.)

  1. Fibroelastic pseudotumor elastofibroma dorsi detected by 18F-FDG PET/CT scan and by postherapy radioiodine SPECT/CT.

    Science.gov (United States)

    Oporto, M; Cepa, F; Orta, N; Rubí, S; Navalón, H; Peña, C

    Radioiodine uptake in the thyroid tissue, metastasis of differentiated thyroid cancer (DTC), and in other tissues, depends on the expression of sodium-iodide symporter (NIS). Vascular permeability, effusions, inflammation, and other mechanisms may also play a role in the accumulation of radioactive iodine. A 63-year-old woman underwent radioiodine therapy, as well as a post-therapy whole-body scan, as she was suspected of having lung metastasis from thyroid carcinoma. The scan not only showed uptake at the lung metastasis but also a faint diffuse bilateral uptake in the posterior thorax. On SPECT/CT this uptake was located in a known Elastofibroma Dorsi (ED) previously diagnosed by contrast CT and viewed in a FDG PET/CT. The radioiodine uptake in ED, especially if typical, is not a diagnostic problem in SPECT/CT study, but can be misleading in a study limited to a few planar images, particularly if the uptake occurs asymmetrically, or ED is located in a unsuspected area. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  2. Development of advanced industrial SPECT system with 12-gonal diverging-collimator

    International Nuclear Information System (INIS)

    Park, Jang Guen; Jung, Sung-Hee; Kim, Jong Bum; Moon, Jinho; Han, Min Cheol; Kim, Chan Hyeong

    2014-01-01

    Industrial single photon emission computed tomography (SPECT) is a promising diagnosis technique to investigate the dynamic behavior of process media. In the present study, a 12-gonal industrial SPECT system was developed using diverging collimators, and its performance was compared with those of hexagonal and 24-gonal systems. Of all of the systems, the 12-gonal type showed the best performance, providing (1) a detection-efficiency map without edge artifacts, (2) the best image resolution, and (3) reconstruction images that correctly furnish multi-source information. Based on the performance of the three different types of configurations, a SPECT system with 12-gonal type configuration was found most suitable for investigating and visualization of flow dynamics in industrial process systems. - highlights: • Industrial SPECT provides the dynamic behavior of multiphase industrial processes. • The present study compared performance of various industrial SPECT systems. • The 12-gonal SPECT system with diverging-collimator provides the best performance

  3. Gallium scintigraphy in Hansen's disease

    International Nuclear Information System (INIS)

    Braga, F.J.H.N.; Sao Paulo Univ., SP; Araejo, E.B.; Camargo, E.E.; Tedesco-Marchesi, L.C.M.; Rivitti, M.C.M.; Bouladour, H.; Galle, P.

    1991-01-01

    Gallium 67 imaging was used in 12 patients with documented Hansen's disease undergoing treatment or not in an attempt to determine the pattern of the disease. Diagnosis was confirmed by histopathology in all patients. The Mitsuda reaction was seen in all patients. Specific nuclear studies were performed when needed to evaluate particular organs better. Gallium 67 images show homogeneous, diffuse and moderate accumulation over the entire skin surface (except for the face) of untreated patients with multibacillary disease. The face skin in these cases presented homogeneous, diffuse but very marked uptake of gallium. Internal organ involvement was variable. There was a very good correlation among clinical, scintigraphical, immunological and histopathological data. The pattern of the body skin ('skin outlining') and face skin ('beard distribution') may be distinct for untreated patients with multibacillary leprosy. (orig.)

  4. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  5. Medical Applications and Toxicities of Gallium Compounds

    Directory of Open Access Journals (Sweden)

    Christopher R. Chitambar

    2010-05-01

    Full Text Available Over the past two to three decades, gallium compounds have gained importance in the fields of medicine and electronics. In clinical medicine, radioactive gallium and stable gallium nitrate are used as diagnostic and therapeutic agents in cancer and disorders of calcium and bone metabolism. In addition, gallium compounds have displayed anti-inflammatory and immunosuppressive activity in animal models of human disease while more recent studies have shown that gallium compounds may function as antimicrobial agents against certain pathogens. In a totally different realm, the chemical properties of gallium arsenide have led to its use in the semiconductor industry. Gallium compounds, whether used medically or in the electronics field, have toxicities. Patients receiving gallium nitrate for the treatment of various diseases may benefit from such therapy, but knowledge of the therapeutic index of this drug is necessary to avoid clinical toxicities. Animals exposed to gallium arsenide display toxicities in certain organ systems suggesting that environmental risks may exist for individuals exposed to this compound in the workplace. Although the arsenic moiety of gallium arsenide appears to be mainly responsible for its pulmonary toxicity, gallium may contribute to some of the detrimental effects in other organs. The use of older and newer gallium compounds in clinical medicine may be advanced by a better understanding of their mechanisms of action, drug resistance, pharmacology, and side-effects. This review will discuss the medical applications of gallium and its mechanisms of action, the newer gallium compounds and future directions for development, and the toxicities of gallium compounds in current use.

  6. Metabolic imaging using SPECT

    International Nuclear Information System (INIS)

    Taki, Junichi; Matsunari, Ichiro

    2007-01-01

    In normal condition, the heart obtains more than two-thirds of its energy from the oxidative metabolism of long chain fatty acids, although a wide variety of substrates such as glucose, lactate, ketone bodies and amino acids are also utilised. In ischaemic myocardium, on the other hand, oxidative metabolism of free fatty acid is suppressed and anaerobic glucose metabolism plays a major role in residual oxidative metabolism. Therefore, metabolic imaging can be an important technique for the assessment of various cardiac diseases and conditions. In SPECT, several iodinated fatty acid traces have been introduced and studied. Of these, 123 I-labelled 15-(p-iodophenyl)3-R, S-methylpentadecanoic acid (BMIPP) has been the most commonly used tracer in clinical studies, especially in some of the European countries and Japan. In this review article, several fatty acid tracers for SPECT are characterised, and the mechanism of uptake and clinical utility of BMIPP are discussed in detail. (orig.)

  7. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, M.; Hack, N.; Tiling, R.; Jakobs, T.; Nikolaou, K.; Becker, C.; Ziegler, F. von; Knez, A.; Koenig, A.; Klauss, V.

    2007-01-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 ± 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  8. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M.; Hack, N.; Tiling, R. [Klinikum Grosshadern (Germany). Dept. of Nuclear Medicine; Jakobs, T.; Nikolaou, K.; Becker, C. [Klinikum Grosshadern (Germany). Dept. of Clinical Radiology; Ziegler, F. von; Knez, A. [Klinikum Grosshadern (Germany). Dept. of Cardiology; Koenig, A.; Klauss, V. [Medizinische Poliklinik-Innenstadt, Univ. of Munich (Germany). Dept. of Cardiology

    2007-07-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting ''obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 {+-} 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  9. Toxicity of indium arsenide, gallium arsenide, and aluminium gallium arsenide

    International Nuclear Information System (INIS)

    Tanaka, Akiyo

    2004-01-01

    Gallium arsenide (GaAs), indium arsenide (InAs), and aluminium gallium arsenide (AlGaAs) are semiconductor applications. Although the increased use of these materials has raised concerns about occupational exposure to them, there is little information regarding the adverse health effects to workers arising from exposure to these particles. However, available data indicate these semiconductor materials can be toxic in animals. Although acute and chronic toxicity of the lung, reproductive organs, and kidney are associated with exposure to these semiconductor materials, in particular, chronic toxicity should pay much attention owing to low solubility of these materials. Between InAs, GaAs, and AlGaAs, InAs was the most toxic material to the lung followed by GaAs and AlGaAs when given intratracheally. This was probably due to difference in the toxicity of the counter-element of arsenic in semiconductor materials, such as indium, gallium, or aluminium, and not arsenic itself. It appeared that indium, gallium, or aluminium was toxic when released from the particles, though the physical character of the particles also contributes to toxic effect. Although there is no evidence of the carcinogenicity of InAs or AlGaAs, GaAs and InP, which are semiconductor materials, showed the clear evidence of carcinogenic potential. It is necessary to pay much greater attention to the human exposure of semiconductor materials

  10. Potential effects of gallium on cladding materials

    International Nuclear Information System (INIS)

    Wilson, D.F.; Beahm, E.C.; Besmann, T.M.; DeVan, J.H.; DiStefano, J.R.; Gat, U.; Greene, S.R.; Rittenhouse, P.L.; Worley, B.A.

    1997-10-01

    This paper identifies and examines issues concerning the incorporation of gallium in weapons derived plutonium in light water reactor (LWR) MOX fuels. Particular attention is given to the more likely effects of the gallium on the behavior of the cladding material. The chemistry of weapons grade (WG) MOX, including possible consequences of gallium within plutonium agglomerates, was assessed. Based on the calculated oxidation potentials of MOX fuel, the effect that gallium may have on reactions involving fission products and possible impact on cladding performance were postulated. Gallium transport mechanisms are discussed. With an understanding of oxidation potentials and assumptions of mechanisms for gallium transport, possible effects of gallium on corrosion of cladding were evaluated. Potential and unresolved issues and suggested research and development (R and D) required to provide missing information are presented

  11. Tc-99m MAG3 SPECT on transplanted kidney

    International Nuclear Information System (INIS)

    Ryu, Jong Gul; Kim, Soon; Zeon, Seok Kil

    1999-01-01

    This study was designed to evaluate the usefulness of a technetium-99m mercaptoacetyltriglycine (Tc-99m MAG3) single photon emission computed tomography (SPECT) performed on transplanted kidney. Thirty renal transplant patients were included in this study. Planar scan was performed for 30 minutes using 555 MBq Tc-99m MAG3. A post-voiding SPECT scan was acquired on the third, seventh, fourteenth and twenty eighth day after transplantation. SPECT scan showed interpretable image quality in 26 of 30 patients (86.7%) and 84 in 120 scans (70%). Fourteen of 26 patients with interpretable SPECT image showed decreased or increased radioactivity, but only 5 had abnormal findings on the planar scan. Focal SPECT defects were seen in allografts with normal function (n=3), acute tubular necrosis (n=3), and acute rejection (n=2). The defects are thought to reflect focally underperfused renal parenchyme or, in normal allografts, an artifact from uneven radioactivity distribution. Four of 10 paints with renal arterial variation showed focally decreased radioactivity and SPECT helped guide further studies that confirmed the exact cause. Five of 10 patients with acute tubular necrosis or acute rejection showed focally decreased radioactivity, but its relation to the patients' clinical course was not clear. Focally increased radioactivity was observed in 5 allografts with normal function and 1 with double ureter in which local clearance delay was observed. Tc-99m MAG3 SPECT renal scan can detect additional focal abnormalities compared to planar scan. Further study is necessary to elucidate the exact clinical significance of the SPECT findings

  12. The origins of SPECT and SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutton, Brian F. [University College London, Institute of Nuclear Medicine, London (United Kingdom); University of Wollongong, Centre for Medical Radiation Physics, Wollongong, NSW (Australia)

    2014-05-15

    Single photon emission computed tomography (SPECT) has a long history of development since its initial demonstration by Kuhl and Edwards in 1963. Although clinical utility has been dominated by the rotating gamma camera, there have been many technological innovations with the recent popularity of organ-specific dedicated SPECT systems. The combination of SPECT and CT evolved from early transmission techniques used for attenuation correction with the initial commercial systems predating the release of PET/CT. The development and acceptance of SPECT/CT has been relatively slow with continuing debate as to what cost/performance ratio is justified. Increasingly, fully diagnostic CT is combined with SPECT so as to facilitate optimal clinical utility. (orig.)

  13. Effects of perfusion detect on the measurement of left ventricular mass, ventricular volume and post-stress left ventricular ejection fraction in gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Ahn, Byeong Cheol; Bae, Sun Keun; Lee, Sang Woo; Jeong, Sin Young; Lee, Jae Tae; Lee, Kyu Bo

    2002-01-01

    The presence of perfusion defect may influence the left ventricular mass (LVM) measurement by quantitative gated myocardial perfusion SPECT (QGS), and ischemic myocardium, usually showing perfusion defect may produce post-stress LV dysfunction. This study was aimed to evaluated the effects of extent and reversibility of perfusion defect on the automatic measurement of LVM by QGS and to investigate the effect of reversibility of perfusion defect on post-stress LV dysfunction. Forty-six patients (male/female=34:12, mean age=64 years) with perfusion defect on myocardial perfusion SPECT underwent rest and post-stress QGS. Forty patients (87%) showed reversible defect. End-diastolic volume (EDV), end-systolic volume (ESV), LV ejection fraction (EF), and LV myocardial volume were obtained from QGS by autoquant program, and LVM was calculated by multiplying the LV myocardial volume by the specific gravity of myocardium. LVMs measured at rest and post-stress QGS showed good correlation, and higher correlation was founded in the subjects with fixed perfusion defect and with small defect (smaller than 20%). There were no significant differences in EDVs, ESVs and EFs between obtained by rest and post-stress QGS in patients with fixed myocardial defect. Whereas, EF obtained by post-stress QGS was lower than that by rest QGS in patients with reversible defect and 10 (25%) of them showed decreases in EF more than 5% in post-stress QGS, as compared to that of rest QGS. Excellent correlations of EDVs, ESVs, EFs between rest and post-stress QGS were noted. Patients with fixed defect had higher correlation between defect can affect LVM measurement by QGS and patients with reversible defect shows post-stress LV dysfunction more frequently than patients with fixed perfusion defect

  14. Role of 99mTc-ECD brain SPECT in the detection of cerebral perfusion abnormality in cases of Attention Deficit Hyperactivity Disorder

    International Nuclear Information System (INIS)

    Kumar, A.; Phom, H.; Thomas, E.J.; Tripathi, M.; Chandrashekar, N.; Bal, C.S.; Zamir, H.; Gulati, S.; Kalra, V.

    2002-01-01

    Aim: A randomized placebo controlled drug trial with Mentat, a herbal pharmacological agent, was initiated in January 2000 in the department of pediatrics at AIIMS, New Delhi, to compare the efficacy of Mentat with a placebo in school children with Attention Deficit Hyperactivity Disorder (ADHD). Materials and Methods: Contact was established with 12 Public schools in Delhi, to identify poor performers in classes I-V (age 6-12 yrs.). About 195 children with poor school performance were recruited in the study. They were screened for causes of poor performance, which included attention problems, hyperactivity, behavior problems, emotional problems, mental sub-normality and learning disability. ADHD suspected children were identified using the Malin's WISC, Connor's rating scale, Problem Behavior checklist, Bender Gestalt test and some sub tests of the Kaufman's Assessment Battery for Children (K-ABC). Sixty children diagnosed as ADHD (using DSM-IV criteria), with an IQ between 90-110, were enrolled into the study. Of the 60 children randomized in the study, 30 received Mentat and 30 received an identical looking placebo. The drug/Placebo was given for a six-month period. 99mTC-ECD brain SPECT was performed in a subset of 34 children with ADHD. Results: Abnormal cerebral perfusion was seen in 23/34; thalamic hypoperfusion in 11, basal ganglia hypoperfusion in 9, thalamus and basal ganglia hypoperfusion in 2 and basifrontal hypoperfusion in 1. So far, in ten children with abnormal pretreatment scans, post treatment scans have also been done. In mentat group, 2/5 children showed normalization of perfusion abnormality after treatment whereas in placebo group, 1/5. Conclusion: This study suggests that there is selective focal cerebral hypoperfusion in cases of ADHD and 99mTc-ECD brain SPECT can be used for evaluation and further monitoring of therapeutic outcome in such cases

  15. Technetium-99m DTPA aerosol and gallium scanning in acquired immune deficiency syndrome

    International Nuclear Information System (INIS)

    Picard, C.; Meignan, M.; Rosso, J.; Cinotti, L.; Mayaud, C.; Revuz, J.

    1987-01-01

    In 11 non-smoking AIDS patients suspected of pneumocystis carinii pneumonia (PCP), the results of Tc-99m DTPA aerosol clearances, gallium scans, and arterial blood gases were compared with those of bronchoalveolar lavage (BAL). Nine patients had PCP. All had increased clearances five times higher than the normal (5.6 +/- 2.3% X min-1 vs 1.1 +/- 0.34% X min-1, N = 10, P less than 0.001), suggesting an increased alveolar permeability. Gallium scans were abnormal in six patients but normal or slightly abnormal in the three others. Four of these nine patients had normal chest x-rays. In two of these the gallium scan was abnormal, but in the two others, only the increased Tc-99m DTPA clearances showed evidence of lung disease. Two patients had normal BAL, with normal clearances and gallium scans. Four out of the nine patients with PCP were studied after treatment. Three recovered and had normal clearance and gallium scans. One still had PCP with increased clearance but normal gallium scan. Gallium scanning and Tc-99m DTPA clearance are useful for detecting lung disease in AIDS patients with suspected PCP and for prompting BAL when chest x-rays and PaO 2 levels are normal. Due to its high sensitivity, a normal Tc-99m DTPA clearance could avoid BAL

  16. {sup 67}Ga-SPECT/CT with a hybrid system in the clinical management of lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Palumbo, Barbara; Sivolella, Silvio; Palumbo, Renato [University of Perugia, Nuclear Medicine Section, Department of Radiological Sciences, Perugia (Italy); Palumbo, Isabella; Liberati, Anna Marina [University of Perugia, Internal Medicine and Oncology, Department of Clinical and Experimental Medicine, Perugia (Italy)

    2005-09-01

    The purpose of this study was to investigate the added value of co-registered fusion imaging using a hybrid system in patients with lymphoma. Twenty-four lymphoma patients underwent {sup 67}Ga-SPECT/CT using a hybrid tomograph consisting of a dual-head, variable-angle gamma camera and a low-dose X-ray tube. Results were compared with those of SPECT alone. Forty-five lesions were identified by SPECT alone, while 49 were detected by SPECT/CT. Forty out of the 45 lesions observed on SPECT were confirmed as lymphoma, but five were due to other causes (thoracic aorta blood pool activity, sialoadenitis in the submandibular gland, bowel activity, rib fracture and bone marrow activation due to radiotherapy). SPECT/CT identified nine more neoplastic lesions compared with SPECT alone: four areas of radiopharmaceutical accumulation were observed in para-aortic lymph nodes, three in the spleen, one in the liver and one in para-iliac lymph nodes. In five cases, SPECT/CT provided additional anatomical information over SPECT alone. In four patients, four large areas of {sup 67}Ga uptake (one mediastinal, two supraclavicular and one para-aortic) were better characterised; in one subject uptake was localised in the seventh thoracic vertebra only by SPECT/CT. Hybrid imaging provided additional data in 13 patients (54.2%), thus inducing oncologists to reconsider the therapeutic approach in eight subjects (33.2%): unnecessary treatment was avoided in four (16.6%) while therapy was altered in another four (16.6%). SPECT/CT hybrid system is able to provide information not obtained by SPECT alone. It allows the anatomical localisation of lymphoma and physiological radiopharmaceutical uptake, facilitates the diagnosis of tumours located in the abdomen (subdiaphragmatic lesions) and provides information that may cause a change in therapeutic strategy. (orig.)

  17. Are oral cathartics of value in optimizing the gallium scan. Concise communication

    International Nuclear Information System (INIS)

    Silberstein, E.B.; Fernandez-Ulloa, M.; Hall, J.

    1981-01-01

    The normal intestinal secretion of 9-15% of an administered dose of gallium-67 may prevent early detection of intra-abdominal disease. We randomized 50 patients to receive either no bowel preparation or 30 cc of milk of magnesia plus 5 cc of cascara. No significant difference was found between the two groups in frequency with which gallium interfered with readings or time to complete the study

  18. Are oral cathartics of value in optimizing the gallium scan? Concise communication.

    Science.gov (United States)

    Silberstein, E B; Fernandez-Ulloa, M; Hall, J

    1981-05-01

    The normal intestinal secretion of 9-15% of an administered dose of gallium-67 may prevent early detection of intra-abdominal disease. We randomized 50 patients to receive either no bowel preparation or 30 cc of milk of magnesia plus 5 cc of cascara. No significant difference was found between the two groups in frequency with which gallium interfered with readings or time to complete the study.

  19. Malignant external otitis: early scintigraphic detection

    International Nuclear Information System (INIS)

    Strashun, A.M.; Nejatheim, M.; Goldsmith, S.J.

    1984-01-01

    Pseudomonas otitis externa in elderly diabetics may extend aggressively to adjacent bone, cranial nerves, meninges, and vessels, leading to a clinical diagnosis of ''malignant'' external otitis. Early diagnosis is necessary for successful treatment. This study compares the findings of initial radiographs, thin-section tomography of temporal bone, CT scans of head and neck, technetium-99m methylene diphosphonate (MDP) and gallium-67 citrate scintigraphy, and single-photon emission computed tomography (SPECT) for detection of temporal bone osteomylitis in ten patients fulfilling the clinical diagnostic criteria of malignant external otitis. Skull radiographs were negative in all of the eight patients studied. Thin-section tomography was positive in one of the seven patients studied using this modality. CT scanning suggested osteomyelitis in three of nine patients. Both Tc-99m and Ga-67 citrate scintigraphy were positive in 10 of 10 patients. These results suggest that technetium and gallium scintigraphy are more sensitive than radiographs and CT scans for early detection of malignant external otitis

  20. Radionuclide cisternography: SPECT and 3D-rendering. Radionuklidzisternographie: SPECT- und 3D-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Henkes, H; Huber, G; Piepgras, U [Universitaet des Saarlandes, Homburg/Saar (Germany, F.R.). Abt. fuer Neuroradiologie; Hierholzer, J [Freie Univ. Berlin (Germany, F.R.). Strahlenklinik und Poliklinik; Cordes, M [British Columbia Univ., Vancouver, BC (Canada). Belzberg Lab. of Neuroscience

    1991-10-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of {sup 111}In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.).

  1. Brain perfusion SPECT in dementia syndromes

    International Nuclear Information System (INIS)

    Libus, P.; Stupalova, J.; Kuzelka, I.; Konrad, J.

    2002-01-01

    Aim: Brain perfusion SPECT is used in differential diagnostics of dementia syndromes. First of all the aim is to distinguish vascular dementia from degenerative dementia and to differentiate dementia from delirium, psychiatric syndromes, depression and secondary dementia, which is important in relation to therapy. The purpose of our study was to detect significance of BP SPECT and include it into the diagnostic process in dementia syndromes. Materials and methods: 51 women and 63 men aged 55 - 88 were evaluated in the study. The patients correspond to the general criteria of dementia diagnosis. They were sent to the examination by neurological, internal and psychiatric departments and out-patient departments. All patients were examined by 99mTc ECD SPECT using a double head camera PRISM 200 VP with LEHR collimator. The scintigraphic data were evaluated by the visual and semiquantitative analysis. Results: It was established that most patients in our group had vascular dementia, while Alzheimer's disease was second. In other groups we found out dementia at strategic infarct location, e.g. in gyrus angularis in the dominant hemisphere, frontal temporal lobe dementia and alcoholic dementia. Twenty-four patients had a normal diagnosis. Fifteen of them had a somatic reason of the delirious state and were re-classified into pseudodementia. Nine patients were not diagnostically included and the examination will repeated in four months time. Conclusion: We have found out a good applicability of brain perfusion SPECT in dementia syndromes diagnosis in our work. The best diagnosticable and most specific were the findings in multi-infarct dementia, Alzheimer's disease and frontal temporal lobe dementia. When vascular dementia is concerned we can even distinguish dementia at strategic infarction location, e.g. in thalamus, basal frontal telencefalon, in gyrus angularis of the dominant hemisphere, etc

  2. A Comparative Study of SPECT, q-EEG and CT in Patients with Mild, Acute Head Trauma

    International Nuclear Information System (INIS)

    Lee, Suk Ho; Kim, Jin Seok; Moon, Hee Seung

    1993-01-01

    Functional cerebral impairments have been verified objectively by brain SPECT and q-EEG (quantitative electroencephalography). Microcerebral circulatory defects without anatomical changes cannot be detected by the brain CT or MRI. Brain SPECT using 99m Tc-HMPAO (Hexamethyl propyleneamine oxime) as a key radioisotope may be accepted as the useful method for identifying functional cerebral impairments. We studied 25 patients with mild head trauma to define whether the SPECT was helpful in detecting cerebral impairment. The SPECT was positive in 23 patients out of 25, q-EEG positive in 16 patients and brain CT was positive in 3 cases. SPECT and q-EEG were more sensitive than CT. SPECT would be more useful method than brain CT to investigate cerebral function after head injury

  3. Design and testing of the measuring equipment for the detection of 71Ge and 69Ge within the gallium-solar-neutrino experiment

    International Nuclear Information System (INIS)

    Huebner, M.

    1980-01-01

    A low level measuring system has been developed for the Ga-solar-neutrino experiment, to detect the reaction 71 Ga (νsub(e),e - ) 71 Ge by the decay 71 Ge (Tsub(1/2) = 11. 4 d, 100% electron capture). An estimate based on the solar standard model gives 15 71 Ge atoms produced by solar neutrinos (pp and pep). As a monitor for background reactions in the target, the detectability of the 69 Ga (p,n) 69 Ge reaction by the decay 69 Ge (Tsub(1/2) = 39 h, 37% β + -decay, 63% electron capture) has been considered. To test the system, the detectors are mounted in a low level laboratory lead box. (orig./WB) [de

  4. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    International Nuclear Information System (INIS)

    Nuutinen, Juho; Liu, Yawu; Laakso, Mikko P.; Karonen, Jari O.; Vanninen, Esko J.; Kuikka, Jyrki T.; Aronen, Hannu J.; Vanninen, Ritva L.

    2009-01-01

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and 99m Tc-labeled ethylcysteinate dimer ( 99m Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. 99m TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  5. Gallium 67 scintigraphic examination of dilated myocardiopathies

    International Nuclear Information System (INIS)

    Lanfranchi, J.; Sachs, R.N.; Beaudet, B.; Deblock, C.; Tellier, P.

    1989-01-01

    Twenty-seven patients were diagnosed as having dilated cardiomyopathies, based on increases in the cardiothoracic index > 0.50, in the diastolic and systolic diameters of the left ventricle, and in the telediastolic volume of the left ventricle, which was indexed by body surface determined by contrast ventriculography. They underwent gallium 67 scintigraphic examination of the myocardium, in order to non-invasively detect the presence of an inflammatory infiltrate. Fifteen of them also had endomyocardial biopsies and all had virology check-up. The results were disappointing. Only in one case was the scintigraphic image undeniably positive; in 20 other patients the findings were dubious or negative. This technique did not demonstrate the presence of an inflammatory infiltrate and thus an association between myocarditis and dilated cardiomyopathy, could not be established [fr

  6. Contrast detail phantom for SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Cabrejas, M.L. de; Arashiro, J G; Giannone, C. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina); Camuyrano, M; Nohara, G [Universidad de Buenos Aires, Buenos Aires (Argentina). Facultad Ciencias Exactas

    1996-06-01

    A new low variable contrast phantom for single photon emission computed tomography (SPECT) was constructed, tested and compared with other existing phantoms. It contains simulated cylindrical lesions of four different diameters (D{sub i}), embedded in a cylindrical scattering medium and a uniform section to evaluate tomographic uniformity. The concentration of tracer in the simulated lesions and the scattering medium (background) can be varied to simulate hot and cold lesions. Different applications of the phantom were tested, including determination of the minimum object contrast (OCm) necessary to detect lesions as a function of lesion size, lesion type (hot or cold) and acquisition and processing protocols by visual inspection. This parameter allows categorization of instruments comparing an `image quality index` (IQI). Preliminary comparison with the Britten contrast processing method showed that the detectable OCm was of the same order of magnitude, but the presented device seems more suitable for training and intercomparison purposes. The constructed phantom, of simple design, has proved to be useful for acquisition and processing condition evaluation, OCm estimation and external quality control. (author). 11 refs, 4 figs.

  7. Aluminium, gallium, indium and thallium

    International Nuclear Information System (INIS)

    Brown, Paul L.; Ekberg, Christian

    2016-01-01

    Aluminium can exist in a number of oxyhydroxide mineral phases including corundum, diaspore, boehmite and gibbsite. The stability constants at zero ionic strength reported for Al(OH) 3 (aq) vary linearly with respect to the inverse of absolute temperature. A full suite of thermodynamic parameters is available for all aluminium phases and hydrolysis species. Gallium hydrolyses to a greater extent than aluminium, with the onset of hydrolysis reactions occurring just above a pHof 1. In fact, even though aluminium has the smallest ionic radius of this series of metals, it has the weakest hydrolysis species and oxide/hydroxide phases.This is due to the presence of stabilising d-orbitals in the heavier metals, gallium, indium and thallium(III). There are few available data for the stability constants of indium(III) hydrolysis species. Of those that are available, the range in the proposed stability constants covers many orders of magnitude.

  8. Collector for recovering gallium from weapons plutonium

    International Nuclear Information System (INIS)

    Philip, C.V.; Anthony, R.G.; Chokkaram, S.

    1998-09-01

    Currently, the separation of gallium from weapons plutonium involves the use of aqueous processing using either solvent extraction of ion exchange. However, this process generates significant quantities of liquid radioactive wastes. A Thermally Induced Gallium Removal process, or TIGR, developed by researchers at Los Alamos National Laboratories, is a simpler alternative to aqueous processing. This research examined this process, and the behavior of gallium suboxide, a vapor that is swept away by passing hydrogen/argon over gallium trioxide/plutonium oxide heated at 1100 C during the TIGR process. Through experimental procedures, efforts were made to prevent the deposition of corrosive gallium onto furnace and vent surfaces. Experimental procedures included three options for gallium removal and collection: (1) collection of gallium suboxide through use of a cold finger; (2) collection by in situ air oxidation; and (3) collection of gallium on copper. Results conclude all three collection mechanisms are feasible. In addition, gallium trioxide exists in three crystalline forms, and each form was encountered during each experiment, and that each form will have a different reactivity

  9. Validation and the limits of SPECT for patients suffering from cerebrovascular accidents. Evaluations based on simultaneous PET and SPECT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1989-02-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO{sub 2}) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO{sub 2} during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO{sub 2} on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO{sub 2} value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO{sub 2} areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.).

  10. A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

    Science.gov (United States)

    Sciammarella, Maria; Shrestha, Uttam M; Seo, Youngho; Gullberg, Grant T; Botvinick, Elias H

    2017-08-03

    analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.

  11. Radiotracers for SPECT imaging. Current scenario and future prospects

    International Nuclear Information System (INIS)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S.

    2012-01-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [ 123 I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [ 123 I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also makes them more

  12. Radiotracers for SPECT imaging. Current scenario and future prospects

    Energy Technology Data Exchange (ETDEWEB)

    Adak, S.; Vijaya Raj, K.K.; Mandal, S. [GE Healthcare Medical Diagnostics, John F. Welch Technology Center, Bangalore (India).; Bhalla, R.; Pickett, R.; Luthra, S.K. [GE Healthcare Medical Diagnostics, The Grove Centre, Amersham (United Kingdom)

    2012-07-01

    Single photon emission computed tomography (SPECT) has been the cornerstone of nuclear medicine and today it is widely used to detect molecular changes in cardiovascular, neurological and oncological diseases. While SPECT has been available since the 1980s, advances in instrumentation hardware, software and the availability of new radiotracers that are creating a revival in SPECT imaging are reviewed in this paper. The biggest change in the last decade has been the fusion of CT with SPECT, which has improved attenuation correction and image quality. Advances in collimator design, replacement of sodium iodide crystals in the detectors with cadmium zinc telluride (CZT) detectors as well as advances in software and reconstruction algorithms have all helped to retain SPECT as a much needed and used technology. Today, a wide spectrum of radiotracers is available for use in cardiovascular, neurology and oncology applications. The development of several radiotracers for neurological disorders is briefly described in this review, including [{sup 123}I]FP-CIT (DaTSCAN trademark) available for Parkinson's disease. In cardiology, while technetium-99m labeled tetrofosmin and technetium-99m labeled sestamibi have been well known for myocardial perfusion imaging, we describe a recently completed multicenter clinical study on the use of [{sup 123}I]mIBG (AdreView trademark) for imaging in chronic heart failure patients. For oncology, while bone scanning has been prevalent, newer radiotracers that target cancer mechanisms are being developed. Technetium-99m labeled RGD peptides have been reported in the literature that can be used for imaging angiogenesis, while technetium-99m labeled duramycin has been used to image apoptosis. While PET/CT is considered to be the more advanced technology particularly for oncology applications, SPECT continues to be the modality of choice and the workhorse in many hospitals and nuclear medicine centers. The cost of SPECT instruments also

  13. Gallium and copper radiopharmaceutical chemistry

    International Nuclear Information System (INIS)

    Green, M.A.; John, E.K.; Barnhart, A.J.

    1990-01-01

    Several isotopes of gallium and copper exhibit nuclear properties that make them attractive for applications in nuclear medicine, most notably Ga-67, Ga-68, Cu-67 and Cu-62. Of these, gamma-emitting Ga-67 has historically found the greatest clinical use, based on the observation that tracer gallium(III) citrate rapidly produces Ga-67 transferrin upon intravenous injection and then slowly affords selective Ga-67 localization in sites of abscess and certain tumors. Copper-67 has received attention as a potential label for tissue-selective monoclonal antibodies, since its associated γ-photons can be used for external imaging and its β - -emissions could be used for radiation therapy. Positron-emitting gallium-68 and copper-62, being available from parent/daughter generator systems, have attracted interest as potential labels for radiopharmaceuticals used in positron emission tomography (PET) because they could reduce the dependence of this imaging technology on hospital-based cyclotrons. The 10 min. half-life of Cu-62 is particularly well-suited to the time frame of PET studies of tissue perfusion, an application for which Cu(II)-bis(thiosemicarbazone) derivatives appear promising. The 68 min. half-life of Ga-68 makes it appropriate for PET studies over longer imaging time spans

  14. Benign versus malignant osseous lesions in spine: differentiation by means of bone SPECT/CT fused image

    International Nuclear Information System (INIS)

    Yao Zhiming; Qu Wanying

    2004-01-01

    This study compared the efficiency of SPECT-CT fused image with planar bone scan, bone SPECT and CT in differentiating malignant from benign lesions and detecting metastases to the spine. Methods. Total 144 patients with spinal lesions underwent planar bone scan (WB), single photon tomography (SPECT), CT and SPECT-CT fused image by a SPECT/CT system. The malignant or benign nature of lesions was proved by radiological Methods, histological findings, 6-24 month follow-up, or all of these. The diagnostic results was divided into 4 types, i.e., normal, benign, doubtful malignant and malignant. Results. There were 137 malignant and 252 benign lesions in 144 patients, respectively. The percentages of doubtful malignant diagnosed by WB, SPECT, CT and fused image are 22.6%, 5.1%, 9.5% and 0%, respectively, p < 0.01-0.001, except for the comparison between the percentages of SPECT and CT. Sensitivities in detection of malignant lesions by WB, SPECT, CT and fused image are 75.2%, 94.2%, 96.6% and 99.3%, respectively, P < 0.001, excepting for the comparisons between those of SPECT and CT, and between those of CT and fused image. The sensitivities m detection of benign lesions by WB, SPECT, CT and fused image are, 56.7%, 86.5%, 90.1% and 96.8%, respectively, P < 0.005 - 0.001, excepting for the comparison between those of SPECT and CT. The specificities in detection of maliganant lesions by WB, SPECT, CT and fused image are 70.6%, 88.9%, 97.2% and 97.6%, respectively, P < 0.001, excepting for the comparison between those of CT and fused image. Conclusion. Bone SPECT-CT fused image has highest diagnostic and differentiating diagnostic values in detection of spinal abnormalities over the planar bone scanning and SPECT. The CT by present SPECT/CT system can complement planar bone scanning and SPECT and is clinically valuable in detection of spinal abnormalities. (authors)

  15. Investigating the role of SPECT/CT in dynamic sentinel lymph node biopsy for penile cancers

    Energy Technology Data Exchange (ETDEWEB)

    Saad, Ziauddin Zia; Bomanji, Jamshed [University College Hospitals London, Department of Nuclear Medicine, London (United Kingdom); UCLH NHS Foundation Trust, Institute of Nuclear Medicine, 5th Floor, London (United Kingdom); Omorphos, Savvas; Malone, Peter; Nigam, Raj; Muneer, Asif [University College Hospitals London, Department of Urology, London (United Kingdom); Michopoulou, Sofia; Gacinovic, Svetislav [University College Hospitals London, Department of Nuclear Medicine, London (United Kingdom)

    2017-07-15

    Currently, most centres use 2-D planar lymphoscintigraphy when performing dynamic sentinel lymph node biopsy in penile cancer patients with clinically impalpable inguinal nodes. This study aimed to investigate the role of SPECT/CT following 2-D planar lymphoscintigraphy (dynamic and static) in the detection and localization of sentinel lymph nodes in the groin. A qualitative (visual) review was performed on planar followed by SPECT/CT lymphoscintigraphy in 115 consecutive patients (age 28-86 years) who underwent injection of {sup 99m}Tc-nanocolloid followed by immediate acquisition of dynamic (20 min) and early static scans (5 min) initially and further delayed static (5 min) images at 120 min followed by SPECT/CT imaging. The lymph nodes detected in each groin on planar lymphoscintigraphy and SPECT/CT were compared. A total of 440 and 467 nodes were identified on planar scintigraphy and SPECT/CT, respectively. Overall, SPECT/CT confirmed the findings of planar imaging in 28/115 cases (24%). In the remaining 87 cases (76%), gross discrepancies were observed between planar and SPECT/CT images. SPECT/CT identified 17 instances of skin contamination (16 patients, 13%) and 36 instances of in-transit lymphatic tract activity (24 patients, 20%) that had been interpreted as tracer-avid lymph nodes on planar imaging. In addition, SPECT/CT identified 53 tracer-avid nodes in 48 patients (42%) that were not visualized on planar imaging and led to reclassification of the drainage basins (pelvic/inguinal) of 27 tracer-avid nodes. The addition of SPECT/CT improved the rate of detection of true tracer-avid lymph nodes and delineated their precise (3-D) anatomic localization in drainage basins. (orig.)

  16. 99mTc-HMPAO SPECT in pediatric patients with neurological disorders

    International Nuclear Information System (INIS)

    Yamaoka, Mitsuko

    1994-01-01

    In 125 pediatric patients with suspected brain diseases, EEG, CT and MRI findings were compared with those obtained with single photon emission computed tomography (SPECT) of the brain using Tc-99m-d, 1-hexamethyl-propylene amine oxime ( 99m Tc-HMPAO), to determine the usefulness of SPECT as an adjunct to EEG, CT and MRI in this age group. The incidences of abnormal finding in the 125 patients were 53.6, 75.2, 60.6 and 51.4% using 99m Tc-HMPAO SPECT, EEG, CT and MRI respectively. In localization-related epilepsy and cerebrovascular diseases, the incidence of abnormality was higher with 99m Tc-HMPAO SPECT than with either CT or MRI. There was a tendency for mean age to be higher and mean IQ or DG lower in patients with more extensive abnormality in comparison to those who had normal or only focally abnormal SPECT findings. Nevertheless, some patients showed focal hypofusion in the frontal or occipital area without significant mental retardation. Epileptic foci detected by EEG corresponded to defects found using 99m Tc-HMPAO SPECT in 34.8% of the symptomatic localization-related epileptic patients. Pathological lesions detected by CT or MRI corresponded with SPECT findings in 48.1% of patients. Furthermore, the incidence of abnormal findings on SPECT was 30% in patients in whom CT or MRI was normal. Epileptic foci detected by EEG did not correspond well with the area of focal hyperfusion found on SPECT. Focal hyperfusion may sometimes occur even in the interictal period or postictal period in childhood seizure disorders. In conclusion, 99m Tc-HMPAO SPECT revealed abnormal findings at a moderate incidence in neuropediatric patients. Correlations with EEG, CT and MRI findings as well as assessment of clinical signs, including the investigation of epileptic foci, are essential for adequate interpretation of brain functions. (author)

  17. Indium gallium nitride/gallium nitride quantum wells grown on polar and nonpolar gallium nitride substrates

    Science.gov (United States)

    Lai, Kun-Yu

    Nonpolar (m-plane or a-plane) gallium nitride (GaN) is predicted to be a potential substrate material to improve luminous efficiencies of nitride-based quantum wells (QWs). Numerical calculations indicated that the spontaneous emission rate in a single In0.15Ga0.85N/GaN QW could be improved by ˜2.2 times if the polarization-induced internal field was avoided by epitaxial deposition on nonpolar substrates. A challenge for nonpolar GaN is the limited size (less than 10x10 mm2) of substrates, which was addressed by expansion during the regrowth by Hydride Vapor Phase Epitaxy (HVPE). Subsurface damage in GaN substrates were reduced by annealing with NH3 and N2 at 950°C for 60 minutes. It was additionally found that the variation of m-plane QWs' emission properties was significantly increased when the substrate miscut toward a-axis was increased from 0° to 0.1°. InGaN/GaN QWs were grown by Metalorganic Chemical Vapor Deposition (MOCVD) on c-plane and m-plane GaN substrates. The QWs were studied by cathodoluminescence spectroscopy with different incident electron beam probe currents (0.1 nA ˜ 1000 nA). Lower emission intensities and longer peak wavelengths from c-plane QWs were attributed to the Quantum-confined Stark Effect (QCSE). The emission intensity ratios of m-plane QWs to c-plane QWs decreased from 3.04 at 1 nA to 1.53 at 1000 nA. This was identified as the stronger screening effects of QCSE at higher current densities in c-plane QWs. To further investigate these effects in a fabricated structure, biased photoluminescence measurements were performed on m-plane InGaN/GaN QWs. The purpose was to detect the possible internal fields induced by the dot-like structure in the InGaN layer through the response of these internal fields under externally applied fields. No energy shifts of the QWs were observed, which was attributed to strong surface leakage currents.

  18. Serial SPECT in children with partial epilepsy

    International Nuclear Information System (INIS)

    Hosoya, Machiko; Ushiku, Hideo

    1995-01-01

    We performed serial single-photon emission CT (SPECT) with N-isopropyl-p-( 123 I)-Iodoamphetamine to measure the regional cerebral blood flow (rCBF) in 15 children with partial epilepsy. SPECT showed focal changes in 14 cases. Ten cases had abnormalities in the initial SPECT and another four cases in the second test. The cases with normal rCBF in initial SPECT had been tested in an early phase after the onset, and then decreased rCBF were observed in the second SPECT. The cases with both abnormal rCBF in the initial SPECT and improved rCBF in the second SPECT showed good prognosis in clinico-electrophysiological evolutions. In cases with abnormal changes of rCBF in the second SPECT, clinical prognosis was found to be not so good. These findings suggest that serial SPECT may be used to follow the course of epilepsy. (author)

  19. 111In-Pentetreotide SPECT/CT in Pulmonary Carcinoid.

    Science.gov (United States)

    Chiaravalloti, Agostino; Spanu, Angela; Danieli, Roberta; Dore, Francesca; Piras, Bastiana; Falchi, Antonio; Tavolozza, Mario; Madeddu, Giuseppe; Schillaci, Orazio

    2015-07-01

    We evaluated somatostatin receptor scintigraphy (SRS) with (111)In-pentetreotide incremental value in pulmonary carcinoid (PC) diagnosis compared to contrast enhanced Computed Tomography (ceCT). We enrolled 81 patients with ascertained PC, 39 at initial staging and 42 in follow-up; the primary tumor had already been excised in 68 cases. Single Photon emission Computed Tomography (SPECT) images were reconstructed with the iterative method and fused with non-enhanced Computed tomography (CT) images. Primary PC or metastatic lesions were ascertained in 55/81 patients and SPECT/CT was positive in 50/55 cases, while ceCT was positive in 44/55. Comparing SPECT/CT with ceCT results, we found a sensitivity of 96 vs. 87.5%, and specificity of 92% vs. 97% for the detection of primary lesion or recurrent disease. A total of 198 lesions were ascertained at SPECT/CT, while 161 at ceCT, with values of sensitivity and specificity of 85.5% and 84.6% for SRS and 75.2% and 90.5% respectively. (111)In-Pentetreotide SPECT/CT proved to be more sensitive and accurate than ceCT, thus enhancing its role in evaluating patients with PC. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  20. On the nature of gallium species in gallium-modified mordenite and MFI zeolites. A comparative DRIFT study of carbon monoxide adsorption and hydrogen dissociation.

    Science.gov (United States)

    Serykh, Alexander I; Kolesnikov, Stanislav P

    2011-04-21

    The results of a DRIFT study of carbon monoxide molecular adsorption and hydrogen dissociative adsorption on gallium-modified mordenite and MFI (ZSM-5) zeolites are presented. It was found that in the reduced gallium-modified mordenite (Ga-MOR) both Ga(3+) and Ga(+) exchanged cations are present and can be detected by CO adsorption. Ga(3+) cations in Ga-MOR dissociatively adsorb molecular hydrogen at elevated temperatures, resulting in the formation of gallium hydride species and acidic hydroxyl groups. In the reduced Ga-MFI evacuated at 823 K under medium vacuum conditions only Ga(+) exchanged intrazeolite cations were detected. It was found, however, that Ga(3+) intrazeolite exchanged cations which form upon high-temperature disproportionation of Ga(+) cations in the reduced Ga-MFI and Ga-MOR can be stabilized by high-temperature oxidation of these zeolites.

  1. Radiolabeled, nonspecific, polyclonal human immunoglobulin in the detection of focal inflammation by scintigraphy: Comparison with gallium-67 citrate and technetium-99m-labeled albumin

    International Nuclear Information System (INIS)

    Rubin, R.H.; Fischman, A.J.; Needleman, M.; Wilkinson, R.; Callahan, R.J.; Khaw, B.A.; Hansen, W.P.; Kramer, P.B.; Strauss, H.W.

    1989-01-01

    The accumulation of nonspecific polyclonal human immunoglobulin (IgG) radiolabeled with 125 I or 111 In was compared to that of [ 67 Ga]citrate and [ 99m Tc]albumin in rats with deep thigh inflammation due to Escherichia coli infection. Serial scintigrams were acquired at 1, 3, 24, and in some cases, 48 hr after injection. As early as 3 hr postinjection, [ 111 In]IgG showed greater accumulation at the lesion than [ 99m Tc]HSA (p less than 0.01). Both [ 125 I]IgG and [ 111 In]IgG showed greater accumulation than [ 67 Ga]citrate (p less than 0.01). At 24 hr, IgG image definition increased, while HSA image definition decreased, and the intensity of accumulation of both IgG preparations was greater than that of [ 67 Ga]citrate or [ 99m Tc]HSA (p less than 0.01). At all imaging times, [ 67 Ga]citrate accumulation was surprisingly low. In inflammation produced by Pseudomonas aeruginosa, Staphylococcus aureus, Klebsiella pneumoniae, Candida albicans, or turpentine, [ 111 In]IgG accumulation was similar to the results obtained with Escherichia coli. These studies suggest that focal sites of inflammation can be detected with radiolabeled nonspecific human polyclonal IgG

  2. Brain perfusion SPECT in children with frequent fits

    International Nuclear Information System (INIS)

    Heiskala, H.; Launes, J.; Pihko, H.; Nikkinen, P.; Santavuori, P.

    1993-01-01

    We studied 14 children with frequent fits using 99m Tc-HM-PAO single photon emission computed tomography (SPECT). There were 11 patients with partial secondary generalized epilepsy (PSGE) and 3 with Lennox-Gastaut syndrome (LGS). The typical regional cerebral blood flow (rCBF) finding in PSGE was a single area of abnormally low perfused cortex, and that in LGS, multiple hypoperfused areas. Clinically, the LGS patients were more severely affected. SPECT was more sensitive in detecting abnormalities than EEG, CT or MRI. Extensive impairment of rCBF may thus indicate unfavourable development of intellectual performance and poor seizure control. (author)

  3. Usefulness of {sup 99m}Tc-HMPAO SPECT in Patients with Subarachnoid Hemorrhage due to Ruptured Intracranial Aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Choi, C. W.; Lee, K. H.; Kim, J. H.; Kwark, C. E.; Lee, D. S.; Chung, J. K.; Lee, M. C.; Han, D. H.; Koh, C. S. [Seoul National University Hospital, Seoul (Korea, Republic of)

    1993-07-15

    We evaluated the usefulness of {sup 99m}Tc-HMPAO SPECT in 21 Patients with subarachnoid hemorrhage due to ruptured intracranial aneurysm and in 3 patients with unruptured intracranial aneurysm. SPECT study could detect the bilaterally hypoperfused cases in 10 patients(48%), but CT/MRI showed the bilateral abnormalities in only 3 patients(14%). The number of abnormal lesions were 56 in SPECT and 25 in CT/MRI. The lesions found in SPECT were well correlated with the neurological signs of the patients such as aphasia or hemiplegia. SPECT study during Matas test was helpful in evaluating the risk for carotid artery occlusion therapy. We thought that {sup 99m}Tc-HMPAO brain SPECT is helpful in evaluating the functional changes in patients with subarachnoid hemorrhage.

  4. Gallium 67 uptake in thymic rebound

    International Nuclear Information System (INIS)

    Hurst, R.; Sabio, H.; Teates, C.D.

    1988-01-01

    We have reported a case of localized thymic enlargement and uptake of gallium 67 in a child who had received antineoplastic chemotherapy. The enlarged thymus showed normal histology, a picture consistent with thymic rebound after nonspecific stress. This case further demonstrates the need to consider thymic rebound as a cause of gallium 67 uptake in children with neoplastic diseases

  5. MRI and brain spect findings in patients with unilateral temporal lobe epilepsy and normal CT scan

    Directory of Open Access Journals (Sweden)

    P.G. Carrilho

    1994-06-01

    Full Text Available 26 patients with temporal lobe epilepsy clinically documented by several abnormal interictal surface EEGs with typical unitemporal epileptiform activity and a normal CT scan were studied. Interictal99mTC HMPAO brain SPECT and MRI were performed in all subjects. Abnormalities were shown in 61.5% of MRI (n=16 and 65.4% of SPECT (n=17. Hippocampal atrophy associated to a high signal on T2-weighted MRI slices suggesting mesial temporal sclerosis was the main finding (n=12; 75% of abnormal MRI. MRI correlated well to surface EEG in 50% (n=13. There was also a good correlation between MRI and SPECT in 30.7% (n=8. SPECT and EEG were in agreement in 57.7% (n=l5. MRI, SPECT and EEG were congruent in 26.9% (n=7. These results support the usefulness of interictal brain SPECT and MRI in detecting lateralized abnormalities in temporal lobe epilepsy. On the other hand, in two cases, interictal SPECT correlated poorly with surface EEG. This functional method should not be used isolately in the detection of temporal lobe foci. MRI is more useful than CT as a neuroimaging technique in temporal lobe epilepsy. It may detect small structural lesions and mesial temporal lobe sclerosis which are not easily seen with traditional CT scanning.

  6. 123I-amphetamine-SPECT in the diagnosis of neurological disorders

    International Nuclear Information System (INIS)

    Biersack, H.J.; Kreiten, K.; Hartmann, A.; Friedrich, G.; Linck, H.A.; Winkler, C.; Bonn Univ.; Rheinische Landesklinik, Bonn

    1985-01-01

    In contrast to conventional brain scintigraphy with sup(99m)Tc-pertechnetate, SPECT with 123 I-IMP enables visualization of the brain tissue itself. The relevance of this imaging technique was evaluated in 54 patients with cerebral disorders. SPECT of the brain was performed with a rotating gamma camera. In 6 of 24 epileptic patients, SPECT revealed foci consistent with EEG-findings which were, however, not detected by CCT. In 4 of 25 patients with cerebrovascular disease, hypoperfused areas were detected by SPECT despite negative results obtained with CCT. In 50% (10/20) of the patients with cerebrovascular disease, SPECT showed a greater functional extent of the lesions than CCT. In 3 patients with migraine and normal CCT, regional perfusion disturbancers were found. SPECT with 123 I-labeled amphetamines, therefore, enables diagnosis of functional perfusion disorders and metabolic disturbances that are not revealed by CCT. In addition, SPECT can be used to exactly demonstrate the functional extent of lesions detected by CCT. (orig.) [de

  7. /sup 123/I-amphetamine-SPECT in the diagnosis of neurological disorders

    Energy Technology Data Exchange (ETDEWEB)

    Biersack, H.J.; Kreiten, K.; Hartmann, A.; Friedrich, G.; Linck, H.A.; Winkler, C.

    1985-03-01

    In contrast to conventional brain scintigraphy with sup(99m)Tc-pertechnetate, SPECT with /sup 123/I-IMP enables visualization of the brain tissue itself. The relevance of this imaging technique was evaluated in 54 patients with cerebral disorders. SPECT of the brain was performed with a rotating gamma camera. In 6 of 24 epileptic patients, SPECT revealed foci consistent with EEG-findings which were, however, not detected by CCT. In 4 of 25 patients with cerebrovascular disease, hypoperfused areas were detected by SPECT despite negative results obtained with CCT. In 50% (10/20) of the patients with cerebrovascular disease, SPECT showed a greater functional extent of the lesions than CCT. In 3 patients with migraine and normal CCT, regional perfusion disturbancers were found. SPECT with /sup 123/I-labeled amphetamines, therefore, enables diagnosis of functional perfusion disorders and metabolic disturbances that are not revealed by CCT. In addition, SPECT can be used to exactly demonstrate the functional extent of lesions detected by CCT.

  8. SPECT imaging of cardiac reporter gene expression in living rabbits

    International Nuclear Information System (INIS)

    Liu Ying; Lan Xiaoli; Zhang Liang; Wu Tao; Jiang Rifeng; Zhang Yongxue

    2009-01-01

    This work is to demonstrate feasibility of imaging the expression of herpes simplex virus 1-thymidine kinase (HSVI-tk) reporter gene in rabbits myocardium by using the reporter probe 131 I-2'-fluoro-2'-deoxy-l-β-D-arabinofuranosyl-5-iodouracil ( 131 I-FIAU) and SPECT. Rabbits of the study group received intramyocardial injection of Ad5-tk and control group received aseptic saline injection. Two sets of experiments were performed on the study group. Rabbits of the 1st set were injected with 131 I-FIAU 600 μCi at Day 2 after intramyocardial transfection of Ad5-tk in 1xl0 9 , 5x10 8 , 1x10 8 , 5x10 7 and 1x10 7 pfu, and heart SPECT imaging was done at different hours. Rabbits of the 2nd were transferred various titers of Ad5-tk (1x10 9 , 5x10 8 , 1x10 8 , 5x10 7 , 1x10 7 pfu) to determine the threshold and optimal viral titer needed for detection of gene expression. Two days later, 131 I-FIAU was injected and heart SPECT imaging was performed at 6, 24 and 48 h, before killing them for gamma counting of the hearts. Reverse transcription-polymerase chain reaction (RT-PCR) was used to verify the transferred HSVI-tk gene expression. Semi-quantitative analysis derived of region of interest (ROI) of SPECT images and RT-PCR images was performed and the relationship of SPECT images with ex vivo gamma counting and mRNA level were evaluated. SPECT images conformed 131 I-FIAU accumulation in rabbits injected with Ad5-tk in the anterolateral wall. The optimal images quality was obtained at 24-48 h for different viral titers. The highest radioactivity in the focal myocardium was seen at 6 h, and then declined with time. The threshold was 5x10 7 pfu of virus titer. The result could be set better in 1-5x10 8 pfu by SPECT analysis and gamma counting. ROI-derived semi-quantitative study on SPECT images correlated well with ex vivo gamma counting and mRNA levels from RT-PCR analysis. The HSVI-tk/ 131 I-FIAU reporter gene/reporter probe system is feasible for cardiac SPECT reporter

  9. Gallium Electromagnetic (GEM) Thrustor Concept and Design

    Science.gov (United States)

    Polzin, Kurt A.; Markusic, Thomas E.

    2006-01-01

    We describe the design of a new type of two-stage pulsed electromagnetic accelerator, the gallium electromagnetic (GEM) thruster. A schematic illustration of the GEM thruster concept is given in Fig. 1. In this concept, liquid gallium propellant is pumped into the first stage through a porous metal electrode using an electromagneticpump[l]. At a designated time, a pulsed discharge (approx.10-50 J) is initiated in the first stage, ablating the liquid gallium from the porous electrode surface and ejecting a dense thermal gallium plasma into the second state. The presence of the gallium plasma in the second stage serves to trigger the high-energy (approx.500 I), send-stage puke which provides the primary electromagnetic (j x B) acceleration.

  10. Interictal brain SPECT in patients with medically refractory temporal lobe epilepsy; SPECT cerebral interictal em pacientes com epilepsia do lobo temporal de dificil controle

    Energy Technology Data Exchange (ETDEWEB)

    Andraus, Maria Emilia Cosenza

    2000-06-01

    The brain single photon emission computed tomography (SPECT) is s functional neuroimaging method that can detect localized changes in cerebral blood flow. The temporal lobe epilepsy (TLE) is the most common epileptic syndrome in adults, and more than 50% are medically refractory. The SPECT can contribute to investigation of epileptogenic focus and is one of the methods of pre-surgical evaluation of these patients. (author)

  11. IMP-SPECT at patients with hallucinations

    International Nuclear Information System (INIS)

    Podreka, I.; Mamoli, B.; Lesch, O.; Suess, E.; Wimberger, D.; Mayr, N.; Havelec, L.; Mueller, C.; Steiner, M.; Deecke, L.

    1986-01-01

    IMP-SPECT was performed in 14 normal volunteers. A 'regional index=RI' of tracer distribution was calculated for 18 regions in each hemisphere RI=(cts/voxel ROI)/(mean cts/voxel of all ROI's). 30 seizure patients (E) and 12 patients with acoustic, partialy also visual hallucinations (H) were investigated. Regions were defined as hypo- or hyperperfused if the RI exceeded the value of the corresponding normal-RI +- 2 std. EEG was recorded in all (E). 93.3% of EEG-findings were abnormal, 50% showed a focus, 46.7% paroxysmal activity. SPECT detected in 93.3% of (E) hypoperfused regions, mostly located in the temporal lobe. All (H) had decreased rCBF, predominantly in the frontal cortex. ANOVA and t-test revealed significant RI-differences in the frontal lobe, both hippocampi, right and left inferior occipital cortex, and right anterior basal ganglia. (H) had lower RI's in frontal lobes, higher RI's in both hippocampal regions as well as inferior occipital regions and anterior basal ganglia Differences between (E) and (H) were found in the frontal lobe ((H)sub(→)), right superior temporal region ((H)sup(→)), left hippocampus ((H)sup(→)), both inferior occipital regions ((H)sup(→)) and right anterior basal ganglia ((H)sup(→)). The study shows that by means of IMP-SPECT hypo- and hyperperfused areas can be detected in the hemispheres of (E) and (H), corresponding to disturbed brain function. Higher hippocampal CBF in (E) and (H) may be related to the role of this limbic structure in generation of seizures and psychotic states. Hallucinations are associated with increased CBF in the right temporal and associative visual cortex. (Author)

  12. Gallium nitride on gallium oxide substrate for integrated nonlinear optics

    KAUST Repository

    Awan, Kashif M.; Dolgaleva, Ksenia; Mumthaz Muhammed, Mufasila; Roqan, Iman S.

    2017-01-01

    Gallium Nitride (GaN), being a direct bandgap semiconductor with a wide bandgap and high thermal stability, is attractive for optoelectronic and electronic applications. Furthermore, due to its high optical nonlinearity — the characteristic of all 111-V semiconductors — GaN is also expected to be a suitable candidate for integrated nonlinear photonic circuits for a plethora of apphcations, ranging from on-chip wavelength conversion to quantum computing. Although GaN devices are in commercial production, it still suffers from lack of a suitable substrate material to reduce structural defects like high densities of threading dislocations (TDs), stacking faults, and grain boundaries. These defects significandy deteriorate the optical quality of the epi-grown GaN layer, since they act as non-radiative recombination centers. Recent studies have shown that GaN grown on (−201) β-Gallium Oxide (Ga2O3) has superior optical quality due to a better lattice matching as compared to GaN grown on Sapphire (Al2O3) [1-3]. In this work, we report on the fabrication of GaN waveguides on GaiOj substrate and their optical characterization to assess their feasibihty for efficient four-wave mixing (FWM).

  13. Gallium nitride on gallium oxide substrate for integrated nonlinear optics

    KAUST Repository

    Awan, Kashif M.

    2017-11-22

    Gallium Nitride (GaN), being a direct bandgap semiconductor with a wide bandgap and high thermal stability, is attractive for optoelectronic and electronic applications. Furthermore, due to its high optical nonlinearity — the characteristic of all 111-V semiconductors — GaN is also expected to be a suitable candidate for integrated nonlinear photonic circuits for a plethora of apphcations, ranging from on-chip wavelength conversion to quantum computing. Although GaN devices are in commercial production, it still suffers from lack of a suitable substrate material to reduce structural defects like high densities of threading dislocations (TDs), stacking faults, and grain boundaries. These defects significandy deteriorate the optical quality of the epi-grown GaN layer, since they act as non-radiative recombination centers. Recent studies have shown that GaN grown on (−201) β-Gallium Oxide (Ga2O3) has superior optical quality due to a better lattice matching as compared to GaN grown on Sapphire (Al2O3) [1-3]. In this work, we report on the fabrication of GaN waveguides on GaiOj substrate and their optical characterization to assess their feasibihty for efficient four-wave mixing (FWM).

  14. Gallium determination in biological samples

    International Nuclear Information System (INIS)

    Stulzaft, O.; Maziere, B.; Ly, S.

    1980-01-01

    A sensitive, simple and time-saving method has been developed for the neutron activation analysis of gallium at concentrations around 10 -4 ppm in biological tissues. After a 24-hour irradiation in a thermal neutron flux of 2.8x10 13 nxcm -2 xs -1 and a purification by ion-exchange chromatography to eliminate troublesome elements such as sodium, iron and copper, the 72 Ga activity is measured with enough accuracy for the method to be applicable in animal physiology and clinical toxicology. (author)

  15. Thermodynamics of gallium arsenide electrodeposition

    International Nuclear Information System (INIS)

    Perrault, G.G.

    1986-01-01

    Gallium Arsenide is well known as a very interesting compound for photoelectrical devices. Up to now, it has been prepared mostly by high temperature technology, and the authors considered that it might be of interest to set up an electrodeposition technique suitable to prepare thin layers of this compound. A reaction sequence similar to the one observed for Cadmium Sulfide or Cadmium Telluride could be considered. In these cases, the metal chalcogenide is obtained from the precipitation of the metal ions dissolved in the solutions by the reduction product of the metalloidic compound

  16. Molecular imaging agents for SPECT (and SPECT/CT)

    International Nuclear Information System (INIS)

    Gnanasegaran, Gopinath; Ballinger, James R.

    2014-01-01

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  17. Molecular imaging agents for SPECT (and SPECT/CT)

    Energy Technology Data Exchange (ETDEWEB)

    Gnanasegaran, Gopinath [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); Ballinger, James R. [Guy' s and St Thomas' NHS Foundation Trust, Department of Nuclear Medicine, London (United Kingdom); King' s College London, Division of Imaging Sciences and Biomedical Engineering, London (United Kingdom)

    2014-05-15

    The development of hybrid single photon emission computed tomography/computed tomography (SPECT/CT) cameras has increased the diagnostic value of many existing single photon radiopharmaceuticals. Precise anatomical localization of lesions greatly increases diagnostic confidence in bone imaging of the extremities, infection imaging, sentinel lymph node localization, and imaging in other areas. Accurate anatomical localization is particularly important prior to surgery, especially involving the parathyroid glands and sentinel lymph node procedures. SPECT/CT plays a role in characterization of lesions, particularly in bone scintigraphy and radioiodine imaging of metastatic thyroid cancer. In the development of novel tracers, SPECT/CT is particularly important in monitoring response to therapies that do not result in an early change in lesion size. Preclinical SPECT/CT devices, which actually have spatial resolution superior to PET/CT devices, have become essential in characterization of the biodistribution and tissue kinetics of novel tracers, allowing coregistration of serial studies within the same animals, which serves both to reduce biological variability and reduce the number of animals required. In conclusion, SPECT/CT increases the utility of existing radiopharmaceuticals and plays a pivotal role in the evaluation of novel tracers. (orig.)

  18. The group study of diagnostic efficacy of cerebro-vascular disease by I-123 IMP SPECT images obtained with ring type SPECT scanner

    International Nuclear Information System (INIS)

    Machida, Kikuo; Honda, Norinari; Matsumoto, Toru

    1991-01-01

    We performed two image reading experiments in order to investigate the diagnostic capability of I-123 IMP SPECT obtained by the ring type SPECT scanner in cerebro-vascular disease. Fourteen physicians diagnosed SPECT images of 55 cases with reference to clinical neurological information, first without brain XCT images and second with XCT images. Each physician detected perfusion defects and redistributions of I-123 IMP and assigned a confidence level of abnormality for these SPECT findings by means of five rating method. From results obtained by ROC analysis, we concluded as follows. (1) Generally, I-123 IMP SPECT is a stable diagnostic modality in the diagnosis of cerebro-vascular disease and the image reading of XCT had no effects on the diagnosis of SPECT on the whole of physician. (2) However, there were unnegligible differences among individuals in the detectability of findings and the effect of XCT image reading. (3) Detectability of redistribution of I-123 IMP was lower than that of perfusion defect and inter-observer variation in the diagnostic performance for redistribution was larger than that of perfusion defect. The results suggest that it is necessary to standardize diagnostic criteria among physicians for redistribution of I-123 IMP. (author)

  19. Clinical application of SPECT in adrenal imaging with iodine-131 6 beta-iodomethyl-19-norcholesterol

    International Nuclear Information System (INIS)

    Ishimura, J.; Kawanaka, M.; Fukuchi, M.

    1989-01-01

    Forty-one patients with or without adrenocortical disorders were studied to evaluate the clinical usefulness of SPECT in adrenal imaging with I-131 Adosterol. In the SPECT images from this study, all glands with either normally functioning or hyperfunctioning adrenal cortices could be detected, while those glands with hypofunctioning adrenal cortices could not be detected. Particularly in transaxial and sagittal slices, the adrenal gland was identified posteriorly and was clearly distinguished from the gallbladder. In preliminary results using SPECT by a standard method, uptake in 68 detectable glands ranged from 1.7% to 4.9% in four glands with Cushing's syndrome, from 1.1% to 1.3% in seven glands with primary aldosteronism, and were distributed below 1.0% in the remaining glands with normally functioning adrenal cortices. These data show that it is possible to evaluate the adrenocortical functioning status simply by analyzing the SPECT images of the adrenal

  20. Clinical application of SPECT in adrenal imaging with iodine-131 6 beta-iodomethyl-19-norcholesterol

    Energy Technology Data Exchange (ETDEWEB)

    Ishimura, J.; Kawanaka, M.; Fukuchi, M.

    1989-04-01

    Forty-one patients with or without adrenocortical disorders were studied to evaluate the clinical usefulness of SPECT in adrenal imaging with I-131 Adosterol. In the SPECT images from this study, all glands with either normally functioning or hyperfunctioning adrenal cortices could be detected, while those glands with hypofunctioning adrenal cortices could not be detected. Particularly in transaxial and sagittal slices, the adrenal gland was identified posteriorly and was clearly distinguished from the gallbladder. In preliminary results using SPECT by a standard method, uptake in 68 detectable glands ranged from 1.7% to 4.9% in four glands with Cushing's syndrome, from 1.1% to 1.3% in seven glands with primary aldosteronism, and were distributed below 1.0% in the remaining glands with normally functioning adrenal cortices. These data show that it is possible to evaluate the adrenocortical functioning status simply by analyzing the SPECT images of the adrenal.

  1. Gallium-based avalanche photodiode optical crosstalk

    International Nuclear Information System (INIS)

    Blazej, Josef; Prochazka, Ivan; Hamal, Karel; Sopko, Bruno; Chren, Dominik

    2006-01-01

    Solid-state single photon detectors based on avalanche photodiode are getting more attention in various areas of applied physics: optical sensors, quantum key distribution, optical ranging and Lidar, time-resolved spectroscopy, X-ray laser diagnostics, and turbid media imaging. Avalanche photodiodes specifically designed for single photon counting semiconductor avalanche structures have been developed on the basis of various materials: Si, Ge, GaP, GaAsP, and InGaP/InGaAs at the Czech Technical University in Prague during the last 20 years. They have been tailored for numerous applications. Trends in demand are focused on detection array construction recently. Even extremely small arrays containing a few cells are of great importance for users. Electrical crosstalk between individual gating and quenching circuits and optical crosstalk between individual detecting cells are serious limitation for array design and performance. Optical crosstalk is caused by the parasitic light emission of the avalanche which accompanies the photon detection process. We have studied in detail the optical emission of the avalanche photon counting structure in the silicon- and gallium-based photodiodes. The timing properties and spectral distribution of the emitted light have been measured for different operating conditions to quantify optical crosstalk. We conclude that optical crosstalk is an inherent property of avalanche photodiode operated in Geiger mode. The only way to minimize optical crosstalk in avalanche photodiode array is to build active quenching circuit with minimum response time

  2. Diagnosis of abdominal abscesses with 67gallium

    International Nuclear Information System (INIS)

    Noguera, E.C.; Mothe, G.A.

    1987-01-01

    Twenty six patients were studied with 67 Gallium to detect and localize the site of intra-abdominal and intraperitoneal infection. They were divided in two groups: a) with and b) without physical symptoms that could localize an abcess in the abdominal cavity. All the patients with suppuration had persistent up-take of 67 Ga in one anatomic area of the abdomen, subsequently documented by computarized axial tomography (CAT) in 58% of the cases or by laparotomy in 88% of them. Scintigraphy with 67 Ga in the patients with recent surgery not only detected focal infection in 67% of the cases but excluded subphernic collection. In 78% of patients with prolonged fever, the infection was localized. There was no false positive result. The comparison in 56% of the cases with CAT demonstrated that both techniques are 100% sensitive for the diagnosis of abdominal suppurative processes. Three of the 26 patients, after six weeks of medical treatment, were restudied with 67 Ga and CAT, showing total resolution of their previous abnormalities. It is concluded that 67 Ga scintigraphy performed as the first study in febrile patients independent of the presence or absence of physical symptoms that could localize the abdominal infection, is sensitive for the detection and localization of an abdominal abscess and that a negative result excludes it. (Author) [es

  3. Evaluation of image reconstruction methods for 123I-MIBG-SPECT. A rank-order study

    International Nuclear Information System (INIS)

    Soederberg, Marcus; Mattsson, Soeren; Oddstig, Jenny; Uusijaervi-Lizana, Helena; Leide-Svegborn, Sigrid; Valind, Sven; Thorsson, Ola; Garpered, Sabine; Prautzsch, Tilmann; Tischenko, Oleg

    2012-01-01

    Background: There is an opportunity to improve the image quality and lesion detectability in single photon emission computed tomography (SPECT) by choosing an appropriate reconstruction method and optimal parameters for the reconstruction. Purpose: To optimize the use of the Flash 3D reconstruction algorithm in terms of equivalent iteration (EI) number (number of subsets times the number of iterations) and to compare with two recently developed reconstruction algorithms ReSPECT and orthogonal polynomial expansion on disc (OPED) for application on 123 I-metaiodobenzylguanidine (MIBG)-SPECT. Material and Methods: Eleven adult patients underwent SPECT 4 h and 14 patients 24 h after injection of approximately 200 MBq 123 I-MIBG using a Siemens Symbia T6 SPECT/CT. Images were reconstructed from raw data using the Flash 3D algorithm at eight different EI numbers. The images were ranked by three experienced nuclear medicine physicians according to their overall impression of the image quality. The obtained optimal images were then compared in one further visual comparison with images reconstructed using the ReSPECT and OPED algorithms. Results: The optimal EI number for Flash 3D was determined to be 32 for acquisition 4 h and 24 h after injection. The average rank order (best first) for the different reconstructions for acquisition after 4 h was: Flash 3D 32 > ReSPECT > Flash 3D 64 > OPED, and after 24 h: Flash 3D 16 > ReSPECT > Flash 3D 32 > OPED. A fair level of inter-observer agreement concerning optimal EI number and reconstruction algorithm was obtained, which may be explained by the different individual preferences of what is appropriate image quality. Conclusion: Using Siemens Symbia T6 SPECT/CT and specified acquisition parameters, Flash 3D 32 (4 h) and Flash 3D 16 (24 h), followed by ReSPECT, were assessed to be the preferable reconstruction algorithms in visual assessment of 123 I-MIBG images

  4. Impact of additional SPECT in bone scanning in tumor patients with suspected metastatic bone disease

    International Nuclear Information System (INIS)

    Apostolova, I.; Goelcuek, E.; Buchert, R.; Brenner, W.; Bohuslavizki, K.H.

    2009-01-01

    The aim of this study was to investigate the additional value of single-photon emission computed tomography (SPECT) for patient staging compared to planar bone scanning in an unselected cohort of cancer patients. The study included 271 consecutive tumor patients in whom planar imaging and two-bed position SPECT of the spine and the pelvis had been performed. Retrospective image interpretation was performed independently for planar and SPECT scans. Findings were categorized as 'benign', 'equivocal', or malignant' on a lesion base, and as 'no metastatic disease', 'equivocal', or metastatic disease' on a patient base. Four hundred and forty seven lesions were detected by SPECT. Missing of lesions in planar images was rare (4.3% of all SPECT lesions). Planar findings differed from SPECT findings in 149 lesions (33.3%). Most of these 'inconsistent' lesions were rated as equivocal in the planar images but benign (14.5% of all lesions) or malignant (11.0%) by SPECT. On a patient base, 81.6% of patients with planar equivocal staging were classified as either benign (55.3%) or malignant (26.3%) by SPECT. Patients definitively staged as 'no metastatic disease' or 'metastatic disease' in planar images were staged differently by SPECT in only 3.7% of cases (up-staging in 2.6% and down-staging in 1.1%). Single-photon emission computed tomography changed a definite staging as based on planar images in less than 4% of the patients. In patients with planar equivocal staging, however, SPECT allowed a definite diagnosis in more than 80% of these cases, and, thus, should be performed routinely in patients with equivocal findings. (author)

  5. Lymphoscintigraphic sentinel node identification in patients with breast cancer: the role of SPECT-CT

    International Nuclear Information System (INIS)

    Lerman, H.; Metser, U.; Lievshitz, G.; Sperber, F.; Shneebaum, S.; Even-Sapir, E.

    2006-01-01

    Lymph node status is a major factor in determining the stage, appropriate therapy and outcome in patients with breast cancer. It is therefore of clinical importance to accurately identify all sentinel nodes (SNs) for each individual tumour before surgery. The purpose of this study was to assess the role of SPECT-CT lymphoscintigraphy in SN identification in patients with breast cancer. Lymphoscintigraphy comprising planar and SPECT-CT acquisition was performed in 157 consecutive patients with breast cancer (mean age 54.7±10.6, range 27-81 years) with a palpable mass (n=100), with a non-palpable mass (n=52) or post lumpectomy (n=5). Planar and SPECT-CT images were interpreted separately and the two imaging techniques were compared with respect to their ability to identify hot nodes. Planar imaging alone was negative for identification of hot nodes in 15% of the patients. SPECT-CT alone was negative in 10% and both techniques were negative in 9% of the patients. Forty-six of the total of 361 (13%) hot nodes identified by lymphoscintigraphy were detected only on SPECT-CT, including 21 nodes obscured by the scattered radiation from the injection site, nine adjacent nodes misinterpreted on planar images as a single node and 16 nodes which were missed on planar images and detected on SPECT data. SPECT-CT detected additional sites of drainage unexpected on planar images, including axillary (n=23 patients), internal mammary (n=5 patients), interpectoral (n=3 patients) and intramammary (n=2 patients) lymph node sites. Fourteen of the 329 (4%) hot lesions seen on planar images were false positive non-nodal sites of uptake that were accurately assessed by SPECT-CT and further validated by surgery. In a single patient, SPECT-CT was negative while planar images identified the SN. (orig.)

  6. Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Akihiko, E-mail: takahsr@hs.med.kyushu-u.ac.jp; Sasaki, Masayuki [Department of Health Sciences, Faculty of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Himuro, Kazuhiko; Yamashita, Yasuo; Komiya, Isao [Division of Radiology, Department of Medical Technology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Baba, Shingo [Department of Clinical Radiology, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan)

    2015-04-15

    superior to SPECT image because of the low background noise. The simulation reveals that the detected photon number in SPECT is comparable to that of PET, but the large fraction (approximately 75%) of scattered and penetration photons contaminates SPECT image. The lower limit of {sup 90}Y detection in SPECT image was approximately 200 kBq/ml, while that in PET image was approximately 100 kBq/ml. Conclusions: By comparing the background noise level and the image concentration profile of both the techniques, PET image quality was determined to be superior to that of bremsstrahlung SPECT. The developed simulation codes will be very useful in the future investigations of PET and bremsstrahlung SPECT imaging of {sup 90}Y.

  7. Technetium-99m-labelled red blood cell imaging in the diagnosis of hepatic haemangiomas: the role of SPECT/CT with a hybrid camera

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio; Danieli, Roberta; Manni, Carlo; Capoccetti, Francesca; Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' ' Tor Vergata' ' , Rome (Italy)

    2004-07-01

    Delayed liver single-photon emission computed tomography (SPECT) after {sup 99m}Tc red blood cell (RBC) labelling is helpful in detecting hepatic haemangiomas; however, diagnosis can be difficult when lesions are situated adjacent to structures like the inferior vena cava, the heart or hepatic vessels, where blood activity persists. The aims of this study were to evaluate the usefulness of RBC SPECT and transmission computed tomography (RBC SPECT/CT) performed simultaneously with a hybrid imaging system for correct characterisation of hepatic lesions in patients with suspected haemangioma, and to assess the additional value of fused images compared with SPECT alone. Twelve patients with 24 liver lesions were studied. The acquisitions of both anatomical (CT) and functional (SPECT) data were performed during a single session. SPECT images were first interpreted alone and then re-evaluated after adding the transmission anatomical maps. Image fusion was successful in all patients, with perfect correspondence between SPECT and CT data, allowing the precise anatomical localisation of sites of increased blood pool activity. SPECT/CT had a significant impact on results in four patients (33.3%) with four lesions defined as indeterminate on SPECT images, accurately characterising the hot spot foci located near vascular structures. In conclusion, RBC SPECT/CT imaging using this hybrid SPECT/CT system is feasible and useful in the identification or exclusion of suspected hepatic haemangiomas located near regions with high vascular activity. (orig.)

  8. SPECT and PET Serve as Molecular Imaging Techniques and in Vivo Biomarkers for Brain Metastases

    Directory of Open Access Journals (Sweden)

    Barbara Palumbo

    2014-06-01

    Full Text Available Nuclear medicine techniques (single photon emission computerized tomography, SPECT, and positron emission tomography, PET represent molecular imaging tools, able to provide in vivo biomarkers of different diseases. To investigate brain tumours and metastases many different radiopharmaceuticals imaged by SPECT and PET can be used. In this review the main and most promising radiopharmaceuticals available to detect brain metastases are reported. Furthermore the diagnostic contribution of the combination of SPECT and PET data with radiological findings (magnetic resonance imaging, MRI is discussed.

  9. SPECT in Focal Epilepsies

    Directory of Open Access Journals (Sweden)

    Roderick Duncan

    2000-01-01

    Full Text Available Brain perfusion changes during seizures were first observed in the 1930s. Single Photon Emission Computed Tomography (SPECT was developed in the 1970s, and tracers suitable for the imaging of regional cerebral perfusion (rCP became available in the 1980s. The method was first used to study rCP in the interictal phase, and this showed areas of low perfusion in a proportion of cases, mainly in patients with temporal lobe epilepsies. However, the trapping paradigm of tracers such as hexamethyl propyleneamine oxime (HMPAO provided a practicable method of studying changes in rCP during seizures, and a literature was established in the late 1980s and early 1990s showing a typical sequence of changes during and after seizures of mesial temporal lobe origin; the ictal phase was associated with large increases in perfusion throughout the temporal lobe, with first the lateral, then the mesial temporal lobe becoming hypoperfused in the postictal phase. Activation and inhibition of other structures, such as the basal ganglia and frontal cortex, were also seen. Studies of seizures originating elsewhere in the brain have shown a variety of patterns of change, according to the structures involved. These changes have been used practically to aid the process of localisation of the epileptogenic zone so that epilepsy surgery can be planned.

  10. Skeletal scintigraphy and SPECT/CT in orthopedic imaging

    International Nuclear Information System (INIS)

    Klaeser, B.; Walter, M.; Krause, T.

    2011-01-01

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  11. Gallium-67 scintigraphy in borderline lepromatous leprosy

    International Nuclear Information System (INIS)

    Mouratidis, B.; Lomas, F.E.

    1993-01-01

    A middle aged woman with a pyrexia of unknown origin was shown to have borderline lepromatous leprosy. Early gallium-67 scintigraphy demonstrated increased uptake in the subcutaneous tissues of the face and thighs. As a result of these findings skin biopsy was obtained from the right thigh which gave a diagnosis of borderline lepromatous leprosy. The authors have been unable to find other reports of gallium-67 scintigraphy in leprosy but the pattern of gallium-67 distribution should suggest the diagnosis. 5 refs., 1 fig

  12. SPECT imaging with resolution recovery

    International Nuclear Information System (INIS)

    Bronnikov, A. V.

    2011-01-01

    Single-photon emission computed tomography (SPECT) is a method of choice for imaging spatial distributions of radioisotopes. Many applications of this method are found in nuclear industry, medicine, and biomedical research. We study mathematical modeling of a micro-SPECT system by using a point-spread function (PSF) and implement an OSEM-based iterative algorithm for image reconstruction with resolution recovery. Unlike other known implementations of the OSEM algorithm, we apply en efficient computation scheme based on a useful approximation of the PSF, which ensures relatively fast computations. The proposed approach can be applied with the data acquired with any type of collimators, including parallel-beam fan-beam, cone-beam and pinhole collimators. Experimental results obtained with a micro SPECT system demonstrate high efficiency of resolution recovery. (authors)

  13. Organ volume estimation using SPECT

    CERN Document Server

    Zaidi, H

    1996-01-01

    Knowledge of in vivo thyroid volume has both diagnostic and therapeutic importance and could lead to a more precise quantification of absolute activity contained in the thyroid gland. In order to improve single-photon emission computed tomography (SPECT) quantitation, attenuation correction was performed according to Chang's algorithm. The dual-window method was used for scatter subtraction. We used a Monte Carlo simulation of the SPECT system to accurately determine the scatter multiplier factor k. Volume estimation using SPECT was performed by summing up the volume elements (voxels) lying within the contour of the object, determined by a fixed threshold and the gray level histogram (GLH) method. Thyroid phantom and patient studies were performed and the influence of 1) fixed thresholding, 2) automatic thresholding, 3) attenuation, 4) scatter, and 5) reconstruction filter were investigated. This study shows that accurate volume estimation of the thyroid gland is feasible when accurate corrections are perform...

  14. PET and SPECT in neurology

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium). Dept. of Radiology and Nuclear Medicine; Vries, Erik F.J. de; Waarde, Aren van [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Otte, Andreas (ed.) [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology

    2014-07-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  15. PET and SPECT in neurology

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Ghent Univ.; Vries, Erik F.J. de; Waarde, Aren van; Otte, Andreas

    2014-01-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  16. 99mTc-HMPAO Brain SPECT in Patients with Post-Traumatic Organic Mental Disorder

    International Nuclear Information System (INIS)

    Lee, Kang Wook; Lee, Dong Jin; Shong, Min Ho; Kang, Min Hee; Ghi, Ick Sung; Shin, Young Tai; Ro, Heung Kyu

    1994-01-01

    It is well known that 99m Tc-HMPAO brain SPECT can reflect the functional lesions better than X-ray computerized tomography(CT) and magnetic resonance imaging(MRI) in the cerebral disorders. In order to evaluate the clinical utilities of 99m Tc-HMPAO brain SPECT in patients with post-traumatic chronic organic mental disorder(OMD). We included 28 patients diagnosed as OMD in department of psychiatry after traumatic head injury. And we compared the results of 99m Tc-HMPAO SPECT with those of MRI, EEG and MINI mental status examination(MMSE). The results were as follows 1) All patients diagnosed as OMD showed diffuse or focal decreased cerebral perfusion on 99m Tc-HMPAO SPECT. 2) Most frequent lesion on brain 99m Tc-HMPAO SPECT was decreased perfusion on both frontal lobe. And most frequent lesion on brain 99m Tc-HMPAO SPECT was decreased perfusion on both frontal lobe. And most frequent lesion on brain 99m Tc-HMPAO SPECT showing normal brain MRI result was also decreased both frontal perfusion. 3) Eight of 28 patients showed focal brain MRI lesions(4 small frontal hygroma, 3 small cerebral infarction and 1 cerebellar encephalomalacia) which were not detected in brain 99m Tc-HMPAO SPECT. 4) The patients showing less than 20 points on MMSE disclosed abnormal results of EEG more frequently than those disclosing more than 20 points. In conclusion, we think that 99m Tc-HMPAO brain SPECT is sensitive method to detect functional lesions of the brains in patients with chronic post-traumatic organic mental disorder.

  17. Thyroid mass estimation in Grave's disease by SPECT

    International Nuclear Information System (INIS)

    Pant, G.S.; Sharma, S.K.; Kumar, R.; Pandey, A.K.; Gupta, A.K.

    2002-01-01

    Aim: One of the important parts of treatment of Grave's disease with I-131 is the delivery of accurate dose to the target volume. Three important parameters that need to be accurately measured for dosimetry are; the 24 hr thyroid uptake (%), the thyroid mass and effective half life of I-131 in the gland. In this presentation we describe the estimation thyroid mass by SPECT. We have standardised a method to estimated thyroid volume by SPECT using thyroid phantoms of different sizes and then used them for routine thyroid mass estimation in patients with Graves' disease. Materials and Methods: Due to variation in thyroid weight in patients with Grave's disease, we standardised the scintigraphic (SPECT) technique using thyroid phantoms of different volumes such as 5 ml, 9.5 ml, 10.5 ml, 35 ml, 80 ml, 101ml and 110 ml. Each phantom was filled with 99 mTc solution with different activity concentration (100 μCi, 300 μCi, 600 μCi and 1.0 μCi) and SPECT images were acquired on a VARICAM dual head camera in 128x128 matrix. The acquired data was processed using a standardised Metz filter but without attenuation or scatter correction. Coronal slices were used with suitable threshold for edge detection. An irregular ROI was plotted around each lobe and isthmus of the thyroid gland and the enclosed slice area was measured. The area measured from all the frames was added and multiplied by the slice thickness to get the volume of the thyroid gland. The estimated volume of each phantom was compared and correlated with its actual volume. The thyroid mass in 40 patients was estimated by SPECT and compared with that estimated by ultrasonography.Results and Conclusion: The results of thyroid mass estimation with SPECT in phantom study suggested a 30% threshold for all phantom volumes. However, 35% threshold was used in patients' images for estimating thyroid volume. The estimated volumes by scintigraphy were compared with that estimated by ultrasonography. A correlation coefficient

  18. Normal anatomy of lung perfusion SPECT scintigraphy

    International Nuclear Information System (INIS)

    Moskowitz, G.W.; Levy, L.M.

    1987-01-01

    Ten patients studies for possible pulmonary embolic disease had normal lung perfusion planar and SPECT scintigraphy. A computer program was developed to superimpose the CT scans on corresponding SPECT images. Superimposition of CT scans on corresponding SPECT transaxial cross-sectional images, when available, provides the needed definition and relationships of adjacent organs. SPECT transaxial sections provide clear anatomic definition of perfusion defects without foreground and background lung tissue superimposed. The location, shape, and size of the perfusion defects can be readily assessed by SPECT. An algorithm was developed for the differentiation of abnormal pulmonary perfusion patterns from normal structures on variation

  19. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  20. Clinical application of cardiac SPECT

    International Nuclear Information System (INIS)

    Nishimura, Shigeyuki

    1999-01-01

    Single-photon emission computed tomography (SPECT) has replaced planar imaging techniques for myocardial scintigraphy. Thallium-201 was the dominant agent employed for myocardial perfusion imaging. Today new technetium-99m labelled radionuclides have been used as excellent alternatives to 201 Tl for detection of coronary artery disease, prognostification, and even assessment of myocardial viability. Pharmacologic stress imaging using either dipyridamole, adenosine or dobutamine is a substitute for exercise stress. Accurate determination of myocardial viability is vitally important for clinical decision making for patients with LV dysfunction who will most benefit from revascularization. Stunned and hibernated myocardium may result in profound regional LTV dysfunction in absence of necrosis. The various approach such as stress-redistribution-reinjection imaging, rest-redistribution imaging and stress-redistribution-24 hours delayed imaging has been utilized to assess myocardial viability with 201 Tl. Quantitative assessment of 99m Tc MIBI uptake reflect the degree of viability. 123 I-Metaiodobenzylguanidine (MIBG), an analog of norepinephrine, has been used for scintigraphic assessment of regional cardiac adrenergic innervation. Cardiac sympathetic denervation, assessed by 123 I-MIBG, due to ischemia in non-Q myocardial infarction and unstable angina has been shown. Quantitative cardiac MIBG scintigram was shown to have prognostic value in patients with severe congestive heart failure. 23 I-BMIPP (ρ-methyl-iodophenyl pentadecanoic acid) has been used to assess myocardial fatty acid utilization. BMIPP has the memory function of ischemia in unstable angina, since decreased BMIPP uptake persists several days after ischemic episode. Nuclear cardiology in Japan has experienced an expansion in the techniques including use of new radionuclides, 99m Tc perfusion agents, 123 I-MIBG and 23 I-BMIPP and in associated clinical application to the various cardiac diseases

  1. [sup 99m]Tc-ECD SPECT study in dementia and aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1993-09-01

    We studied clinical significance of [sup 99m]Tc-L,L,-ethyl cysteine dimer ([sup 99m]Tc-ECD) SPECT study in dementia and aphasia, and compared it with [sup 99m]Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in [sup 99m]Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in [sup 99m]Tc-HMPAO SPECT. The count rate ratios in [sup 99m]Tc-ECD and [sup 99m]Tc-HMPAO SPECT were correlated well with each other, and the contrast of the [sup 99m]Tc-ECD SPECT image was equivalent or slightly higher as compared with [sup 99m]Tc-HMPAO. Therefore, [sup 99m]Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author).

  2. 99mTc-ECD SPECT study in dementia and aphasia

    International Nuclear Information System (INIS)

    Kuwabara, Yasuo; Ichiya, Yuichi; Otsuka, Makoto; Sasaki, Masayuki; Akashi, Yuko; Fukumura, Toshimitsu; Yoshida, Tsuyoshi; Masuda, Kouji; Ichimiya, Atsushi

    1993-01-01

    We studied clinical significance of 99m Tc-L,L,-ethyl cysteine dimer ( 99m Tc-ECD) SPECT study in dementia and aphasia, and compared it with 99m Tc-HMPAO SPECT study. The subjects consisted of 13 patients, including 10 patients with dementia and 3 patients with aphasia. Hypoperfusion areas were detected in 5 out of 10 patients with dementia and 2 out of 3 patients with aphasia in 99m Tc-ECD SPECT, and in 4 out of 10 patients with dementia and all of 3 patients with aphasia in 99m Tc-HMPAO SPECT. The count rate ratios in 99m Tc-ECD and 99m Tc-HMPAO SPECT were correlated well with each other, and the contrast of the 99m Tc-ECD SPECT image was equivalent or slightly higher as compared with 99m Tc-HMPAO. Therefore, 99m Tc-ECD SPECT study was considered to be useful for the evaluation of cerebral perfusion in dementia and aphasia. (author)

  3. Gallium-67 activity in bronchoalveolar lavage fluid in sarcoidosis

    International Nuclear Information System (INIS)

    Trauth, H.A.; Heimes, K.; Schubotz, R.; von Wichert, P.

    1986-01-01

    Roentgenograms and gallium-67 scans and gallium-67 counts of BAL fluid samples, together with differential cell counts, have proved to be useful in assessing activity and lung involvement in sarcoidosis. In active pulmonary sarcoidosis gallium-67 scans are usually positive. Quantitation of gallium-67 uptake in lung scans, however, may be difficult. Because gallium-67 uptake and cell counts in BAL fluid may be correlated, we set out to investigate gallium-67 activity in BAL fluid recovered from patient of different groups. Sixteen patients with recently diagnosed and untreated sarcoidosis, nine patients with healthy lungs, and five patients with CFA were studied. Gallium-67 uptake of the lung, gallium-67 activity in the lavage fluid, SACE and LACE levels, and alpha 1-AT activity were measured. Significantly more gallium-67 activity was found in BAL fluid from sarcoidosis patients than in that from CFA patients (alpha = .001) or patients with healthy lungs (alpha = .001). Gallium-67 activity in BAL fluid could be well correlated with the number of lymphocytes in BAL fluid, but poorly with the number of macrophages. Subjects with increased levels of SACE or serum alpha 1-AT showed higher lavage gallium-67 activity than did normals, but no correlation could be established. High gallium-67 activity in lavage fluid may be correlated with acute sarcoidosis or physiological deterioration; low activity denotes change for the better. The results show that gallium-67 counts in BAL fluid reflects the intensity of gallium-67 uptake and thus of activity of pulmonary sarcoidosis

  4. Localization of functioning parathyroid adenomas by SPECT/CT. Report of two cases

    International Nuclear Information System (INIS)

    Pruzzo C, Rossana; Amaral P, Horacio; Rossi F, Ricardo; Morales K, Barbara; Martinez G, M.Eugenia

    2013-01-01

    Single photon emission computed tomography and computed tomography (SPECT/CT), integrates a gamma camera and a CT scan and is effective for the location of parathyroid adenomas. We report a 55 years old male and a 80 years old female with primary hyperparathyroidism. In both cases the 99m Tc-Sestamibi parathyroid scintigraphy detected a functioning nodule whose presence was confirmed with SPECT/CT

  5. Interictal brain SPECT in patients with medically refractory temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Andraus, Maria Emilia Cosenza

    2000-06-01

    The brain single photon emission computed tomography (SPECT) is s functional neuroimaging method that can detect localized changes in cerebral blood flow. The temporal lobe epilepsy (TLE) is the most common epileptic syndrome in adults, and more than 50% are medically refractory. The SPECT can contribute to investigation of epileptogenic focus and is one of the methods of pre-surgical evaluation of these patients. (author)

  6. NIM Realization of the Gallium Triple Point

    Science.gov (United States)

    Xiaoke, Yan; Ping, Qiu; Yuning, Duan; Yongmei, Qu

    2003-09-01

    In the last three years (1999 to 2001), the gallium triple-point cell has been successfully developed, and much corresponding research has been carried out at the National Institute of Metrology (NIM), Beijing, China. This paper presents the cell design, apparatus and procedure for realizing the gallium triple point, and presents studies on the different freezing methods. The reproducibility is 0.03 mK, and the expanded uncertainty of realization of the gallium triple point is evaluated to be 0.17 mK (p=0.99, k=2.9). Also, the reproducibility of the gallium triple point was compared with that of the triple point of water.

  7. Glutathione role in gallium induced toxicity

    African Journals Online (AJOL)

    Asim

    2012-01-26

    Jan 26, 2012 ... 1Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Gomal University, D.I. Khan, ... Decrease in GSH level was dependant on gallium nitrate concentration. .... This 2 ml mixture sample was centrifuged at 1000.

  8. Properties of gallium lanthanum sulphide glass

    OpenAIRE

    Bastock, P.; Craig, C.; Khan, K.; Weatherby, E.; Yao, J.; Hewak, D.W.

    2015-01-01

    A series of gallium lanthanum sulphide (GLS) glasses has been studied in order to ascertain properties across the entire glass forming region. This is the first comprehensive study of GLS glass over a wide compositional range.

  9. Glutathione role in gallium induced toxicity

    African Journals Online (AJOL)

    Asim

    2012-01-26

    GSH) present in tissues. It is very important and interesting to study the reaction of gallium nitrate and glutathione as biomarker of glutathione role in detoxification and conjugation in whole blood components (plasma and ...

  10. Clinical applications of Gallium-68

    International Nuclear Information System (INIS)

    Banerjee, Sangeeta Ray; Pomper, Martin G.

    2013-01-01

    Gallium-68 is a positron-emitting radioisotope that is produced from a 68 Ge/ 68 Ga generator. As such it is conveniently used, decoupling radiopharmacies from the need for a cyclotron on site. Gallium-68-labeled peptides have been recognized as a new class of radiopharmaceuticals showing fast target localization and blood clearance. 68 Ga-DOTATOC, 8 Ga-DOTATATE, 68 Ga-DOTANOC, are the most prominent radiopharmaceuticals currently in use for imaging and differentiating lesions of various somatostatin receptor subtypes, overexpressed in many neuroendocrine tumors. There has been a tremendous increase in the number of clinical studies with 68 Ga over the past few years around the world, including within the United States. An estimated ∼10,000 scans are being performed yearly in Europe at about 100 centers utilizing 68 Ga-labeled somatostatin analogs within clinical trials. Two academic sites within the US have also begun to undertake human studies. This review will focus on the clinical experience of selected, well-established and recently applied 68 Ga-labeled imaging agents used in nuclear medicine. - Highlights: ► A summary of the emerging clinical uses of 68 Ga-based radiopharmaceuticals is provided. ► 68 Ga-PET may prove as or more clinically robust than the corresponding 18 F-labeled agents. ► 68 Ga-radiopeptides were studied for targeting of somatostatin receptors subtypes. ► 68 Ga-DOTATOC, 68 Ga-DOTATATE, 68 Ga-DOTANOC, are currently in clinical trials

  11. Metal Contacts to Gallium Arsenide.

    Science.gov (United States)

    Ren, Fan

    1991-07-01

    While various high performance devices fabricated from the gallium arsenide (GaAs) and related materials have generated considerable interest, metallization are fundamental components to all semiconductor devices and integrated circuits. The essential roles of metallization systems are providing the desired electrical paths between the active region of the semiconductor and the external circuits through the metal interconnections and contacts. In this work, in-situ clean of native oxide, high temperature n-type, low temperature n-type and low temperature p-type ohmic metal systems have been studied. Argon ion mill was used to remove the native oxide prior to metal deposition. For high temperature process n-type GaAs ohmic contacts, Tungsten (W) and Tungsten Silicide (WSi) were used with an epitaxial grown graded Indium Gallium Arsenide (InGaAs) layer (0.2 eV) on GaAs. In addition, refractory metals, Molybdenum (Mo), was incorporated in the Gold-Germanium (AuGe) based on n-type GaAs ohmic contacts to replace conventional silver as barrier to prevent the reaction between ohmic metal and chlorine based plasma as well as the ohmic metallization intermixing which degrades the device performance. Finally, Indium/Gold-Beryllium (In/Au-Be) alloy has been developed as an ohmic contact for p-type GaAs to reduce the contact resistance. The Fermi-level pinning of GaAs has been dominated by the surface states. The Schottky barrier height of metal contacts are about 0.8 V regardless of the metal systems. By using p-n junction approach, barrier height of pulsed C-doped layers was achieved as high as 1.4 V. Arsenic implantation into GaAs method was also used to enhance the barrier height of 1.6 V.

  12. The clinical usefulness of Tc-99m ECD brain SPECT in acute measles encephalitis

    International Nuclear Information System (INIS)

    Lim, Seok Tae; Sohn, Myung Hee

    2003-01-01

    Since the prognosis of measles encephalitis is poor, early diagnosis and proper management are very important to improve clinical outcomes. We compared Tc-99m ECD brain SPECT (SPECT) with MR imaging (MRI) for the detection of acute measles encephalitis. Eleven patients (M : F=4 : 7, age range 18 months-14 yrs) with acute measles encephalitis were enrolled in this studies. All of them underwent both MRI and SPECT. The results of SPECT were scored from 0 (normal) to 3 (most severe defect) according to perfusion state. We compared two image modalities for the detection of brain abnormality in acute measles encephalitis. Seven of 11 patients (63.6%) revealed high signal intensity in the white matter on T2WI of MRI, on the other hand all patients (100%) showed hypoperfusion on SPECT. Severe perfusion deficits above score 2 were located with decreasing frequencies in the frontal lobe (81.8%), temporal lobe (72.7%), occipital lobe (27.3%), basal ganglia (27.3%), and parietal lobe (9.1%). We conclude that SPECT is more useful than MRI for the detection of brain involvement in patients with acute measles encephalitis

  13. The clinical usefulness of Tc-99m ECD brain SPECT in acute measles encephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Seok Tae; Sohn, Myung Hee [School of Medicine, Chonbuk National Univ., Chonju (Korea, Republic of)

    2003-08-01

    Since the prognosis of measles encephalitis is poor, early diagnosis and proper management are very important to improve clinical outcomes. We compared Tc-99m ECD brain SPECT (SPECT) with MR imaging (MRI) for the detection of acute measles encephalitis. Eleven patients (M : F=4 : 7, age range 18 months-14 yrs) with acute measles encephalitis were enrolled in this studies. All of them underwent both MRI and SPECT. The results of SPECT were scored from 0 (normal) to 3 (most severe defect) according to perfusion state. We compared two image modalities for the detection of brain abnormality in acute measles encephalitis. Seven of 11 patients (63.6%) revealed high signal intensity in the white matter on T2WI of MRI, on the other hand all patients (100%) showed hypoperfusion on SPECT. Severe perfusion deficits above score 2 were located with decreasing frequencies in the frontal lobe (81.8%), temporal lobe (72.7%), occipital lobe (27.3%), basal ganglia (27.3%), and parietal lobe (9.1%). We conclude that SPECT is more useful than MRI for the detection of brain involvement in patients with acute measles encephalitis.

  14. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual 201 Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of the coronary reserves

    International Nuclear Information System (INIS)

    Mendoza V, R.

    2004-01-01

    The objective of this work was to determine if the images of SPECT 201 TI in rest of 15 minutes, 24 late hours and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of 201 TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT 201 TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of 201 TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT 99m Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  15. Salivary SPECT and factor analysis in Sjoegren's syndrome

    International Nuclear Information System (INIS)

    Nakamura, T.; Oshiumi, Y.; Yonetsu, K.; Muranaka, T.; Sakai, K.; Kanda, S.; National Fukuoka Central Hospital

    1991-01-01

    Salivary SPECT and factor analysis in Sjoegren's syndrome were performed in 17 patients and 6 volunteers as controls. The ability of SPECT to detect small differences in the level of uptake can be used to separate glands from background even when uptake is reduced as in the patients with Sjoegren's syndrome. In control and probable Sjoegren's syndrome groups the uptake ratio of the submandibular gland to parotid gland on salivary SPECT (S/P ratio) was less than 1.0. However, in the definite Sjoergren's syndrome group, the ratio was more than 1.0. Moreover, the ratio in all patients with sialectasia, which is characteristic of Sjoegren's syndrome, was more than 1.0. Salivary factor analysis of normal parotid glands showed slowly increasing patterns of uptake and normal submandibular glands had rapidly increasing patterns of uptake. However, in the definite Sjoegren's syndrome group, the factor analysis patterns were altered, with slowly increasing patterns dominating both in the parotid and submandibular glands. These results suggest that the S/P ratio in salivary SPECT and salivary factor analysis provide additional radiologic criteria in diagnosing Sjoegren's syndrome. (orig.)

  16. Radionuclide cisternography: SPECT and 3D-rendering

    International Nuclear Information System (INIS)

    Henkes, H.; Huber, G.; Piepgras, U.; Hierholzer, J.; Cordes, M.

    1991-01-01

    Radionuclide cisternography is indicated in the clinical work-up for hydrocephalus, when searching for CSF leaks, and when testing whether or not intracranial cystic lesions are communicating with the adjacent subarachnoid space. This paper demonstrates the feasibility and diagnostic value of SPECT and subsequent 3D surface rendering in addition to conventional rectilinear CSF imaging in eight patients. Planar images allowed the evaluation of CSF circulation and the detection of CSF fistula. They were advantageous in examinations 48 h after application of 111 In-DTPA. SPECT scans, generated 4-24 h after tracer application, were superior in the delineation of basal cisterns, especially in early scans; this was helpful in patients with pooling due to CSF fistula and in cystic lesions near the skull base. A major drawback was the limited image quality of delayed scans, when the SPECT data were degraded by a low count rate. 3D surface rendering was easily feasible from SPECT data and yielded high quality images. The presentation of the spatial distribution of nuclide-contaminated CSF proved especially helpful in the area of the basal cisterns. (orig.) [de

  17. The role of SPECT in the evaluation of skeletal trauma

    Energy Technology Data Exchange (ETDEWEB)

    Murray, I P.C. [Prince of Wales Hospital, Randwick (Australia)

    1993-02-01

    Single photon emission computed tomography (SPECT) has, in the last decade, established a critical role in routine diagnosis. Skeletal scintigraphy exemplifies the impact in improving detection of lesions by delineation of their site and size. The advantage of minimizing the superimposed radioactivity from overlying and underlying structures is typified by the readiness with which avascular necrosis of the femoral head can be identified by removal of the surrounding hyperaemia which masks the classical photopaenia. However, the ability to achieve an accurate image at a plane at a prescribed depth is most characteristically shown by the study of a vertebra, a bone of irregular contour and subject to a variety of pathological disorders at different sites within it. The various focal abnormalities resulting from these can be localized exactly, readily distinguishing, for example, those in the body from those in the natural arch. In particular, the alterations resulting from trauma, such as pars interarticularis stress fracture, are readily seen. Consequently SPECT has an indispensable role in the investigation and management of low back pain. However, the ability of SPECT to delineate abnormal accumulation has provided a new approach to the evaluation of knee pain, especially when acute such as that resulting from athletic injury, since the identification of the presence or absence of focal abnormalities can be critical to patient management. The frequency of these various disorders in which SPECT is so useful explains why the procedure has become such a routine high-volume examination in so many departments. (author).

  18. An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability

    International Nuclear Information System (INIS)

    He Xin; Links, Jonathan M; Frey, Eric C

    2010-01-01

    Quantum noise as well as anatomic and uptake variability in patient populations limits observer performance on a defect detection task in myocardial perfusion SPECT (MPS). The goal of this study was to investigate the relative importance of these two effects by varying acquisition time, which determines the count level, and assessing the change in performance on a myocardial perfusion (MP) defect detection task using both mathematical and human observers. We generated ten sets of projections of a simulated patient population with count levels ranging from 1/128 to around 15 times a typical clinical count level to simulate different levels of quantum noise. For the simulated population we modeled variations in patient, heart and defect size, heart orientation and shape, defect location, organ uptake ratio, etc. The projection data were reconstructed using the OS-EM algorithm with no compensation or with attenuation, detector response and scatter compensation (ADS). The images were then post-filtered and reoriented to generate short-axis slices. A channelized Hotelling observer (CHO) was applied to the short-axis images, and the area under the receiver operating characteristics (ROC) curve (AUC) was computed. For each noise level and reconstruction method, we optimized the number of iterations and cutoff frequencies of the Butterworth filter to maximize the AUC. Using the images obtained with the optimal iteration and cutoff frequency and ADS compensation, we performed human observer studies for four count levels to validate the CHO results. Both CHO and human observer studies demonstrated that observer performance was dependent on the relative magnitude of the quantum noise and the patient variation. When the count level was high, the patient variation dominated, and the AUC increased very slowly with changes in the count level for the same level of anatomic variability. When the count level was low, however, quantum noise dominated, and changes in the count level

  19. Myocardial Impairment Detected by Late Gadolinium Enhancement in Hypertrophic Cardiomyopathy: Comparison with 99mTc-MIBI/Tetrofosmin and 123I-BMIPP SPECT

    OpenAIRE

    Hashimura, Hiromi; Kiso, Keisuke; Yamada, Naoaki; Kono, Atsushi; Morita, Yoshiaki; Fukushima, Kazuto; Higashi, Masahiro; Noguchi Teruo; Ishibashi-Ueda, Hatsue; Naito, Hiroaki; Sugimura, Kazuro

    2013-01-01

    Purpose: Myocardial fibrosis is considered to be an important factor in myocardial dysfunction and sudden cardiac death in hypertrophic cardiomyopathy (HCM). The purpose of this study was to compare myocardial fibrosis detected by late gadolinium enhancement (LGE) on cardiac MRI with myocardial perfusion and fatty acid metabolism assessed by single photon emission computed tomography in HCM.Materials and Methods: We retrospectively evaluated 20 consecutive HCM patients (female, 7; mean age, 5...

  20. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    International Nuclear Information System (INIS)

    Sundstroem, Torbjoern; Riklund, Katrine Aa.; Elgh, Eva; Naesman, Birgitta; Larsson, Anne; Nyberg, Lars

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2±4.8 years) with mild AD and 18 healthy elderly (69.4±3.9 years) were included in the study. The subjects were injected with 99m Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF 99m Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  1. Functional brain imaging with SPECT in normal again and dementia. Methodological, pathophysiological, and diagnostic aspects

    International Nuclear Information System (INIS)

    Waldemar, G.

    1996-03-01

    New developments in instrumentation, radiochemistry, and data analysis, particularly the introduction of 99m Tc-labeled brain-retained tracers for perfusion studies, have opened up a new era of single photon emission computed tomography (SPECT). In this review critical methodological issues relating to the SPECT instrument, the radioactive tracers, the scanning procedure, the data analysis and interpretation of data, and subject selection are discussed together with the changes in regional cerebral blood flow (rCBF) observed in normal aging. An overview is given of the topography and the pathophysiological and diagnostic significance of focal rCBF deficits in Alzheimer's disease and in other dementia disorders, in which SPECT is capable of early or preclinical disease detection. In Alzheimer's disease, the diagnostic sensitivity and specificity of focal rCBF deficits measured with SPECT and brain-retained tracers are very high, in particular when combined with medial temporal lob atrophy on CT. Together with neuropsychological testing, SPECT serves to map the topography of brain dysfunction. Thus, in the clinical setting, SPECT provides information that is supplemental to that obtained in other studies. Future applications include neuroreceptor studies and treatment studies, in which SPECT may serve as a diagnostic aid in the selection of patients and as a potential mean for monitoring treatment effects. Although positron emission tomography is the best characterized tool for addressing some of these clinical and research issues in dementia, only the less expensive and technically simpler SPECT technique will have the potential of being available as a screening diagnostic instrument in the clinical setting. It is concluded that, properly approached, functional brain imaging with SPECT represents an important tool in the diagnosis, management, and research of dementia disorders. (au) 251 refs

  2. Clinical significance of I-123 IMP brain SPECT in children with brain diseases

    International Nuclear Information System (INIS)

    Takishima, Teruo; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Hasegawa, Noriko

    1990-01-01

    Single photon emission computed tomography (SPECT) of the brain using N-isopropyl p-I-123-iodoamphetamine (I-123 IMP) was performed in 43 children with suspected brain diseases. Forty-three children (25 males and 18 females), with an age range of 24 days-15 years (mean: 6.6 years), were included in the study. Six patients were subsequently diagnosed as normal. Early SPECT of the brain was performed 30 minutes after intravenous administration of 74-111 MBq (2-3 mCi) I-123 IMP using a rotating gamma camera equipped with a 30-degree slant hole and medium energy collimator. Transverse images were reconstructed by Shepp-Logan filtered back projection method with attenuation correction after spatial filtering using an 8th order Butterworth-Wiener filter. Findings of I-123 IMP SPECT were compared with those of X-ray computed tomography (CT) and electroencephalography (EEG). The results showed that in I-123 IMP SPECT, abnormality was found in 30 out of 37 children with brain diseases. The incidence of abnormal findings in the 37 patients was 81% in I-123 IMP SPECT, 61% in X-ray CT, and 78% in EEG; in both cryptogenic and secondary epilepsy, the incidence of abnormality was higher in I-123 IMP SPECT than in X-ray CT. (70% and 94% vs 50% and 81% respectively), and epileptic foci detected by EEG did not correspond with defects found using I-123 IMP SPECT in 27% of the patients; and in asphyxiated infants, a high incidence of abnormality was observed on both I-123 IMP SPECT (86%) and X-ray CT (86%). In conclusion, I-123 IMP SPECT is a clinically useful examination in children with brain disease. (author)

  3. PET and SPECT in psychiatry

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Otte, Andreas; Vries, Erik F.J. de; Waarde, Aren van

    2014-01-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  4. SPECT og PET i neurobiologien

    DEFF Research Database (Denmark)

    Paulson, O.B.; Lassen, N.A.

    1997-01-01

    PET (positron emission tomography) and SPECT (single photon emission computed tomography) are isotopic methods in which the distribution is registered of radiolabelled tracers given in such small amounts that they are without effect on the organism or the organism's disposal of them. Thus, a series...

  5. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  6. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime [Nara Medical Univ., Kashihara (Japan)

    2002-03-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  7. Effect of bypass on the motor activation SPECT compared to the acetazolamide SPECT

    International Nuclear Information System (INIS)

    Kawaguchi, Shoichiro; Iwahashi, Hideaki; Sakaki, Toshisuke; Imai, Teruhiko; Ohishi, Hajime

    2002-01-01

    The authors evaluated and analyzed motor activation single photon emission computed tomography (M-SPECT) in ischemic cerebrovascular disease compared to resting and acetazolamide (ACZ) activated SPECT studies. Seventeen cases with STA-MCA bypass performed for ischemic cerebrovascular disease were examined. The SPECT studies consisting of resting, ACZ activation, and motor activation stages were performed before bypass, at 1 month, and 3 months after bypass. The result of the M-SPECT was expressed as negative or positive. Before bypass: In all 17 cases, SPECT studies of the affected side showed reduction of resting cerebral blood flow (CBF) and reduction of cerebrovascular reserve capacity (CVRC). Eight cases were positive in the M-SPECT study. One week after bypass: The resting CBF increased in seven cases. Four showed preoperative positive M-SPECT. Eight cases showed improvement of the CVRC. Twelve cases were positive in M-SPECT, and two were negative in the preoperative M-SPECT. Three months after bypass: Thirteen cases showed improvement in the resting CBF, and fourteen cases showed improvement of the CVRC. Fourteen cases were positive in the M-SPECT, and among these, 6 were negative in the preoperative M-SPECT. There was a discrepancy between the improvement in CVRC and M-SPECT. M-SPECT study can provide information about the degree of hemodynamic compromise and effect of bypass surgery. (author)

  8. Sodium enhances indium-gallium interdiffusion in copper indium gallium diselenide photovoltaic absorbers.

    Science.gov (United States)

    Colombara, Diego; Werner, Florian; Schwarz, Torsten; Cañero Infante, Ingrid; Fleming, Yves; Valle, Nathalie; Spindler, Conrad; Vacchieri, Erica; Rey, Germain; Guennou, Mael; Bouttemy, Muriel; Manjón, Alba Garzón; Peral Alonso, Inmaculada; Melchiorre, Michele; El Adib, Brahime; Gault, Baptiste; Raabe, Dierk; Dale, Phillip J; Siebentritt, Susanne

    2018-02-26

    Copper indium gallium diselenide-based technology provides the most efficient solar energy conversion among all thin-film photovoltaic devices. This is possible due to engineered gallium depth gradients and alkali extrinsic doping. Sodium is well known to impede interdiffusion of indium and gallium in polycrystalline Cu(In,Ga)Se 2 films, thus influencing the gallium depth distribution. Here, however, sodium is shown to have the opposite effect in monocrystalline gallium-free CuInSe 2 grown on GaAs substrates. Gallium in-diffusion from the substrates is enhanced when sodium is incorporated into the film, leading to Cu(In,Ga)Se 2 and Cu(In,Ga) 3 Se 5 phase formation. These results show that sodium does not decrease per se indium and gallium interdiffusion. Instead, it is suggested that sodium promotes indium and gallium intragrain diffusion, while it hinders intergrain diffusion by segregating at grain boundaries. The deeper understanding of dopant-mediated atomic diffusion mechanisms should lead to more effective chemical and electrical passivation strategies, and more efficient solar cells.

  9. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations

    International Nuclear Information System (INIS)

    Montes, C.; Hernandez, J.; Gomez-Caminero, F.; Garcia, S.; Martin, C.; Rosero, A.; Tamayo, P.

    2013-01-01

    Hybrid imaging, such as single photon emission computed tomography (SPECT)/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose. (author)

  10. Detection of myocardial viability by means of Single Proton Emission Computed Tomography (Perfused SPECT) dual {sup 201} Tl (rest of 15 minutes, 24 late hours and 24 hours reinjection) and gated-SPECT {sup 99m} Tc-SESTAMIBI in effort or stimulation of the coronary reserves; Deteccion de viabilidad miocardica mediante tomografia por emision de foton unico (SPECT perfusorio) dual {sup 201} Talio (Reposo de 15 minutos, 24 horas tardio y 24 horas reinyeccion) y gated-SPECT {sup 99m} Tc-SESTAMIBI en esfuerzo o estimulo de reserva coronaria

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza V, R

    2004-07-01

    The objective of this work was to determine if the images of SPECT {sup 201} TI in rest of 15 minutes, 24 late hours and Gated-SPECT {sup 99m} Tc-SESTAMIBI in effort or stimulation of coronary reservation correlate with the study of 24 hours post reinjection of {sup 201}TI to determine the presence of having knitted viable myocardium. Material and methods: 29 patients were studied with coronary arterial illness (EAC) to who are carried out SPECT {sup 201} TI in rest with images of 15 minutes, 24 late hours and 24 hours reinjection, by means of the administration of {sup 201}TI to dose of 130 MBq and reinjection with 37 MBq. and Gated-SPECT {sup 99m}Tc-SESTAMIBI in effort or stimulation of coronary reservation, later to the administration of 1110 MBq. Results: 29 patients were included according to inclusion approaches and exclusion, of those which 22 (75.86%) they correspond at the masculine sex and 7 (24.13%) to the feminine one, with an average of 62.1 year-old age, 2320 segments myocardial were analysed so much it is phase post-effort as rest; they were diagnosed a total of 264 segments with heart attack, of which viability myocardium was observed in 174 segments. The statistical tests are analysis of frequencies. The non parametric test of Wilcoxon and Mann-Whitney. Conclusions: the viability myocardial at the 24 late hours and 24 hours reinjection was similar; significant difference exists between the study of 15 minutes and 24 hours reinjection, ischemic illness was also demonstrated in territories different to the heart attack area in the studies of 15 minutes, late 24 hours and 24 hours reinjection. (Author)

  11. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-01-01

    201 Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by 201 Tl myocardial SPECT was high, and 201 Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author)

  12. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by /sup 201/Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-03-01

    /sup 201/Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by /sup 201/Tl myocardial SPECT was high, and /sup 201/Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author).

  13. The role of hybrid SPECT-CT in oncology: current and emerging clinical applications

    International Nuclear Information System (INIS)

    Chowdhury, F.U.; Scarsbrook, A.F.

    2008-01-01

    Single photon emission computed tomography - computed tomography (SPECT-CT) is an emerging dual-modality imaging technique with many established and potential clinical applications in the field of oncology. To date, there has been a considerable emphasis on the benefits of integrated positron emission tomography - computed tomography (PET-CT) in oncology, but relatively little focus on the clinical utility of SPECT-CT. As with PET-CT, accurate co-registration of anatomical and functional data from a combined SPECT-CT camera often provides complementary diagnostic information. Both sensitivity (superior disease localization) and specificity (exclusion of false-positives due to physiological tracer uptake) are improved, and the functional significance of indeterminate lesions detected on cross-sectional imaging can be defined. This article will review the scope of hybrid SPECT-CT in oncology and illustrate both current and emerging clinical applications

  14. The role of SPECT-CT in the lymphoscintigraphic identification of sentinel nodes in patients with oral cancer

    DEFF Research Database (Denmark)

    Bilde, Anders; Von Buchwald, Christian; Mortensen, Jann

    2006-01-01

    SPECT with higher resolution CT scanners are expected to provide more accurate information about the localization of SNs. OBJECTIVE: To assess the role of combined SPECT-CT in SN identification in the clinically negative neck of patients with OSCC. MATERIALS AND METHODS: Lymphoscintigraphy comprising......CONCLUSION: SPECT-CT may improve the localization of sentinel nodes (SNs) in patients with oral squamous cell carcinoma (OSCC). Compared with planar lymphoscintigraphy SPECT-CT detected more SNs and provided additional anatomical and spatial information about their localization. New generation...... planar and SPECT-CT acquisition was performed in 34 consecutive patients with OSCC stage I and II (T1-2N0M0) prior to sentinel node biopsy (SNB) and selective neck dissection. The number of SNs and anatomical location was recorded according to lymphoscintigraphy and operative findings. RESULTS: SNB...

  15. Practical reconstruction protocol for quantitative 90Y bremsstrahlung SPECT/CT

    International Nuclear Information System (INIS)

    Siman, W.; Mikell, J. K.; Kappadath, S. C.

    2016-01-01

    Purpose: To develop a practical background compensation (BC) technique to improve quantitative 90 Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a 90 Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar 90 Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical 90 Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for 90 Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity

  16. Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Siman, W.; Mikell, J. K.; Kappadath, S. C., E-mail: skappadath@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas 77030 (United States)

    2016-09-15

    detectability and activity quantification compared to SPECT with AC only. The proposed methodology can readily be used to tailor {sup 90}Y SPECT/CT acquisition and reconstruction protocols with different SPECT/CT systems for quantification and improved image quality in clinical settings.

  17. The contribution of bone SPECT to the diagnosis of bone metastases in an African population

    International Nuclear Information System (INIS)

    Elmadini, A.E.; Warwick, J.M.; Ellmann, A.

    2004-01-01

    Full text: Introduction: A number of studies have demonstrated the value of performing spinal SPECT in addition to planar scintigraphy for the diagnosis of bone metastases. This has however not been demonstrated in an African population where patients frequently present with more advanced disease. The aim of this study was to investigate the contribution of spinal SPECT to the diagnosis of bone metastases in an African population. Materials and methods: In a retrospective study of 576 patients with known primary tumours who underwent skeletal scintigraphy for the diagnosis of bone metastases, the students of 119 patients who underwent planar imaging and SPECT were reviewed. Blinded to the SPECT study, the planar studies were graded for the probability of metastatic disease using a four-point scale, and the number of spinal lesions was noted. This was repeated with the planar and SPECT studies reviewed together. The interpretation using the planar images alone was compared with that obtained after the addition of SPECT using non-parametric tests. Results: Of the 576 patients, 119 (45 men and 74 women) underwent planar and SPECT imaging. A wide variety of primary malignancies were presented but the majority consisted of breast carcinoma (n=55) and prostate carcinoma (n=29). The addition of SPECT resulted in a significant change in the interpretation of these studies (p<0.05), with a significantly lower proportion of patients having equivocal gradings (p<0.01). However the actual number of patients affected was relatively small (n=35) representing about 6% of the total of 576 patients. The addition of SPECT also resulted in the detection of significantly more spinal lesions (p<0.01 ). Conclusion: The addition of SPECT resulted in a statistically significant change in the interpretation of the studies, demonstrating the value of spinal SPECT in this population. However compared to the total patient population the actual number of patients affected was relatively small

  18. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  19. Imaging fusion (SPECT/CT) in degenerative disease of spine

    International Nuclear Information System (INIS)

    Bernal, P.; Ucros, G.; Bermudez, S.; Ocampo, M.

    2007-01-01

    which allowed us to address the treatment. In all cases, CT provided exact anatomical localization. Conclusion; Fusion imaging SPECT/CT in degenerative pathology of spine allows an integration of the anatomical detail with the functional information. It improves the diagnostic accuracy: Determining sites of greater metabolic activity in patients with multiple degenerative changes and improving the spatial localization in injuries detected by scintigraphy. Image fusion by SPECT/CT could have a clinical impact (34% of our series) in that the treatment was modified. (author)

  20. Window structure for passivating solar cells based on gallium arsenide

    Science.gov (United States)

    Barnett, Allen M. (Inventor)

    1985-01-01

    Passivated gallium arsenide solar photovoltaic cells with high resistance to moisture and oxygen are provided by means of a gallium arsenide phosphide window graded through its thickness from arsenic rich to phosphorus rich.

  1. Normal vibrations in gallium arsenide

    International Nuclear Information System (INIS)

    Dolling, G.; Waugh, J.L.T.

    1964-01-01

    The triple axis crystal spectrometer at Chalk River has been used to observe coherent slow neutron scattering from a single crystal of pure gallium arsenide at 296 o K. The frequencies of normal modes of vibration propagating in the [ζ00], (ζζζ], and (0ζζ] crystal directions have been determined with a precision of between 1 and 2·5 per cent. A limited number of normal modes have also been studied at 95 and 184 o K. Considerable difficulty was experienced in obtaining welt resolved neutron peaks corresponding to the two non-degenerate optic modes for very small wave-vector, particularly at 296 o K. However, from a comparison of results obtained under various experimental conditions at several different points in reciprocal space, frequencies (units 10 12 c/s) for these modes (at 296 o K) have been assigned: T 8·02±0·08 and L 8·55±02. Other specific normal modes, with their measured frequencies are (a) (1,0,0): TO 7·56 ± 008, TA 2·36 ± 0·015, LO 7·22 ± 0·15, LA 6·80 ± 0·06; (b) (0·5, 0·5, 0·5): TO 7·84 ± 0·12, TA 1·86 ± 0·02, LO 7·15 ± 0·07, LA 6·26 ± 0·10; (c) (0, 0·65, 0·65): optic 8·08 ±0·13, 7·54 ± 0·12 and 6·57 ± 0·11, acoustic 5·58 ± 0·08, 3·42 · 0·06 and 2·36 ± 004. These results are generally slightly lower than the corresponding frequencies for germanium. An analysis in terms of various modifications of the dipole approximation model has been carried out. A feature of this analysis is that the charge on the gallium atom appears to be very small, about +0·04 e. The frequency distribution function has been derived from one of the force models. (author)

  2. Normal vibrations in gallium arsenide

    Energy Technology Data Exchange (ETDEWEB)

    Dolling, G; Waugh, J L T

    1964-07-01

    The triple axis crystal spectrometer at Chalk River has been used to observe coherent slow neutron scattering from a single crystal of pure gallium arsenide at 296{sup o}K. The frequencies of normal modes of vibration propagating in the [{zeta}00], ({zeta}{zeta}{zeta}], and (0{zeta}{zeta}] crystal directions have been determined with a precision of between 1 and 2{center_dot}5 per cent. A limited number of normal modes have also been studied at 95 and 184{sup o}K. Considerable difficulty was experienced in obtaining welt resolved neutron peaks corresponding to the two non-degenerate optic modes for very small wave-vector, particularly at 296{sup o}K. However, from a comparison of results obtained under various experimental conditions at several different points in reciprocal space, frequencies (units 10{sup 12} c/s) for these modes (at 296{sup o}K) have been assigned: T 8{center_dot}02{+-}0{center_dot}08 and L 8{center_dot}55{+-}02. Other specific normal modes, with their measured frequencies are (a) (1,0,0): TO 7{center_dot}56 {+-} 008, TA 2{center_dot}36 {+-} 0{center_dot}015, LO 7{center_dot}22 {+-} 0{center_dot}15, LA 6{center_dot}80 {+-} 0{center_dot}06; (b) (0{center_dot}5, 0{center_dot}5, 0{center_dot}5): TO 7{center_dot}84 {+-} 0{center_dot}12, TA 1{center_dot}86 {+-} 0{center_dot}02, LO 7{center_dot}15 {+-} 0{center_dot}07, LA 6{center_dot}26 {+-} 0{center_dot}10; (c) (0, 0{center_dot}65, 0{center_dot}65): optic 8{center_dot}08 {+-}0{center_dot}13, 7{center_dot}54 {+-} 0{center_dot}12 and 6{center_dot}57 {+-} 0{center_dot}11, acoustic 5{center_dot}58 {+-} 0{center_dot}08, 3{center_dot}42 {center_dot} 0{center_dot}06 and 2{center_dot}36 {+-} 004. These results are generally slightly lower than the corresponding frequencies for germanium. An analysis in terms of various modifications of the dipole approximation model has been carried out. A feature of this analysis is that the charge on the gallium atom appears to be very small, about +0{center_dot}04 e. The

  3. Perfusion differences on SPECT and PWI in patients with acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nuutinen, Juho [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Liu, Yawu; Laakso, Mikko P. [Kuopio University Hospital, University of Kuopio, Department of Neurology, Kuopio (Finland); Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland); Karonen, Jari O. [Mikkeli Central Hospital, Department of Radiology, Mikkeli (Finland); Vanninen, Esko J. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Kuikka, Jyrki T. [Kuopio University Hospital, University of Kuopio, Department of Clinical Physiology and Nuclear Medicine, Kuopio (Finland); Niuvanniemi Hospital, Kuopio (Finland); Aronen, Hannu J. [University of Turku, Department of Radiology, Turku (Finland); Vanninen, Ritva L. [Kuopio University Hospital, University of Kuopio, Department of Clinical Radiology, P. O. Box 1777, Kuopio (Finland)

    2009-10-15

    The purposes of the present study were to compare the flow defect volumes on perfusion-weighted magnetic resonance imaging (PWI) and {sup 99m}Tc-labeled ethylcysteinate dimer ({sup 99m}Tc-ECD) single photon emission computed tomography (SPECT) at acute and subacute stages of ischemic stroke and to analyze the relationship between the detected flow defects on the two methods and neurological status and clinical outcomes. Perfusion defects on PWI and SPECT were measured within 48 h and on day 8 of the onset of stroke from 22 patients with their first-ever acute supratentorial ischemic stroke. The primary neurological status was evaluated prior to the imaging. Clinical outcome was assessed at 3 months after the onset of the stroke. The volumes of cerebral blood flow (CBF) defects did not differ between SPECT and PWI within the 48-h examinations. However, the volume of CBF defect was significantly larger on SPECT than on PWI on day 8 (p = 0.03). Within the 48-h examinations, the CBF defect volumes on SPECT and PWI were comparably related to the neurological status. On day 8, the CBF defect volume on SPECT showed higher correlation to the neurological status and more precisely predicted the clinical outcomes at 3 months than PWI. {sup 99m}TC-ECD-SPECT and PWI both have ability to detect cerebral hypoperfusion in patients with ischemic stroke but with some differences. The value of SPECT is more accurate in terms of the delayed outcome, such as prognosis and rehabilitation planning. (orig.)

  4. Comparative analysis of MR imaging, Ictal SPECT and EEG in temporal lobe epilepsy: a prospective IAEA multi-center study

    Energy Technology Data Exchange (ETDEWEB)

    Zaknun, John J. [University Hospital of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); International Atomic Energy Agency (IAEA), Nuclear Medicine Section, Division of Human Health, Vienna (Austria); IAEA, Nuclear Medicine Section, Division of Human Health, Wagramer Strasse 5, P.O. Box 100, Wien (Austria); Bal, Chandrasekhar [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India); Maes, Alex [Katholieke Universiteit Leuven, Leuven (Belgium); AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Tepmongkol, Supatporn [Chulalongkorn University, Nuclear Medicine Division, Department of Radiology, Bangkok (Thailand); Vazquez, Silvia [Instituto de Investigaciones Neurologicas, FLENI, Department of Radiology, Buenos Aires (Argentina); Dupont, Patrick [Katholieke Universiteit Leuven, Leuven (Belgium); Dondi, Maurizio [Ospedale Maggiore, Department of Nuclear Medicine, Bologna (Italy); International Atomic Energy Agency (IAEA), Nuclear Medicine Section, Division of Human Health, Vienna (Austria)

    2008-01-15

    MR imaging, ictal single-photon emission CT (SPECT) and ictal EEG play important roles in the presurgical localization of epileptic foci. This multi-center study was established to investigate whether the complementary role of perfusion SPECT, MRI and EEG for presurgical localization of temporal lobe epilepsy could be confirmed in a prospective setting involving centers from India, Thailand, Italy and Argentina. We studied 74 patients who underwent interictal and ictal EEG, interictal and ictal SPECT and MRI before surgery of the temporal lobe. In all but three patients, histology was reported. The clinical outcome was assessed using Engel's classification. Sensitivity values of all imaging modalities were calculated, and the add-on value of SPECT was assessed. Outcome (Engel's classification) in 74 patients was class I, 89%; class II, 7%; class III, 3%; and IV, 1%. Regarding the localization of seizure origin, sensitivity was 84% for ictal SPECT, 70% for ictal EEG, 86% for MRI, 55% for interictal SPECT and 40% for interictal EEG. Add-on value of ictal SPECT was shown by its ability to correctly localize 17/22 (77%) of the seizure foci missed by ictal EEG and 8/10 (80%) of the seizure foci not detected by MRI. This prospective multi-center trial, involving centers from different parts of the world, confirms that ictal perfusion SPECT is an effective diagnostic modality for correctly identifying seizure origin in temporal lobe epilepsy, providing complementary information to ictal EEG and MRI. (orig.)

  5. Comparative analysis of MR imaging, Ictal SPECT and EEG in temporal lobe epilepsy: a prospective IAEA multi-center study

    International Nuclear Information System (INIS)

    Zaknun, John J.; Bal, Chandrasekhar; Maes, Alex; Tepmongkol, Supatporn; Vazquez, Silvia; Dupont, Patrick; Dondi, Maurizio

    2008-01-01

    MR imaging, ictal single-photon emission CT (SPECT) and ictal EEG play important roles in the presurgical localization of epileptic foci. This multi-center study was established to investigate whether the complementary role of perfusion SPECT, MRI and EEG for presurgical localization of temporal lobe epilepsy could be confirmed in a prospective setting involving centers from India, Thailand, Italy and Argentina. We studied 74 patients who underwent interictal and ictal EEG, interictal and ictal SPECT and MRI before surgery of the temporal lobe. In all but three patients, histology was reported. The clinical outcome was assessed using Engel's classification. Sensitivity values of all imaging modalities were calculated, and the add-on value of SPECT was assessed. Outcome (Engel's classification) in 74 patients was class I, 89%; class II, 7%; class III, 3%; and IV, 1%. Regarding the localization of seizure origin, sensitivity was 84% for ictal SPECT, 70% for ictal EEG, 86% for MRI, 55% for interictal SPECT and 40% for interictal EEG. Add-on value of ictal SPECT was shown by its ability to correctly localize 17/22 (77%) of the seizure foci missed by ictal EEG and 8/10 (80%) of the seizure foci not detected by MRI. This prospective multi-center trial, involving centers from different parts of the world, confirms that ictal perfusion SPECT is an effective diagnostic modality for correctly identifying seizure origin in temporal lobe epilepsy, providing complementary information to ictal EEG and MRI. (orig.)

  6. What does rCBF-SPECT offer in schizophrenia?

    International Nuclear Information System (INIS)

    Syed, G.M.S.; Barrett, J.J.; Toone, B.K.

    1992-01-01

    Schizophrenia is a major psychiatric problem common in the younger population. Structural imaging and findings on autopsy have not yet revealed a specific deficit in these patients. Uncertainty in clinical diagnosis based on a set of signs and symptoms is another drawback in the management of this patient population. Regional cerebral blood flow studies (rCBF) using single photon emission computed tomography (SPECT) offers the opportunity to study the underlying phenomenon and to detect the specific functional deficits in schizophrenia. (Author)

  7. Point defects in gallium arsenide characterized by positron annihilation spectroscopy and deep level transient spectroscopy

    International Nuclear Information System (INIS)

    Mih, R.; Gronsky, R.; Sterne, P.A.

    1995-01-01

    Positron annihilation lifetime spectroscopy (PALS) is a unique technique for detection of vacancy related defects in both as-grown and irradiated materials. The authors present a systematic study of vacancy defects in stoichiometrically controlled p-type Gallium Arsenide grown by the Hot-Wall Czochralski method. Microstructural information based on PALS, was correlated to crystallographic data and electrical measurements. Vacancies were detected and compared to electrical levels detected by deep level transient spectroscopy and stoichiometry based on crystallographic data

  8. Myocardial impairment detected by late gadolinium enhancement in hypertrophic cardiomyopathy: comparison with 99mTc-MIBI/tetrofosmin and 123I-BMIPP SPECT.

    Science.gov (United States)

    Hashimura, Hiromi; Kiso, Keisuke; Yamada, Naoaki; Kono, Atsushi; Morita, Yoshiaki; Fukushima, Kazuto; Higashi, Masahiro; Noguchi, Teruo; Ishibashi-Ueda, Hatsue; Naito, Hiroaki; Sugimura, Kazuro

    2013-06-17

    Myocardial fibrosis is considered to be an important factor in myocardial dysfunction and sudden cardiac death in hypertrophic cardiomyopathy (HCM). The purpose of this study was to compare myocardial fibrosis detected by late gadolinium enhancement (LGE) on cardiac MRI with myocardial perfusion and fatty acid metabolism assessed by single photon emission computed tomography in HCM. We retrospectively evaluated 20 consecutive HCM patients (female, 7; mean age, 53.4 years) who underwent LGE, technetium-99m methoxyisobutylisonitrile/tetrofosmin (99mTc-MIBI/tetrofosmin), and iodine-123 beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) imaging. We calculated the myocardium-to-lumen signal ratio (M/L) for LGE in 17 segments based on the American Heart Association statement. Scoring of 99mTc-MIBI/tetrofosmin (PI) and 123I-BMIPP (BM) was performed for each segment using a 5-point scale (0, normal; 4, highly decreased). Nineteen of 20 patients (95%) and 153 of 340 segments (45%) showed LGE. M/Ls were 0.42±0.16, 0.55±0.17, and 0.65±0.24 in PI0/BM0, PI0/BM1-4 and PI1-4/BM1-4, respectively. All M/Ls were significantly higher than that of a normal control (0.34±0.14) (pacid metabolism, and is more strongly associated with disorders of fatty acid metabolism than with perfusion abnormalities. M/L may be a useful indicator of disease severity.

  9. SPECT and PET imaging in epilepsy

    International Nuclear Information System (INIS)

    Semah, F.

    2007-01-01

    Positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging are very useful for the management of patients with medically refractory partial epilepsy. Presurgical evaluation of patients with medically refractory partial epilepsy often included PET imaging using FDG. The use of SPECT in these patients adds some more information and gives the clinicians the possibility of having ictal imaging. Furthermore, PET and SPECT imaging are performed to better understand the pathophysiology of epilepsy. (authors)

  10. Image fusion analysis of 99mTc-HYNIC-Tyr3-octreotide SPECT and diagnostic CT using an immobilisation device with external markers in patients with endocrine tumours

    International Nuclear Information System (INIS)

    Gabriel, Michael; Hausler, Florian; Moncayo, Roy; Decristoforo, Clemens; Virgolini, Irene; Bale, Reto; Kovacs, Peter

    2005-01-01

    The aim of this study was to assess the value of multimodality imaging using a novel repositioning device with external markers for fusion of single-photon emission computed tomography (SPECT) and computed tomography (CT) images. The additional benefit derived from this methodological approach was analysed in comparison with SPECT and diagnostic CT alone in terms of detection rate, reliability and anatomical assignment of abnormal findings with SPECT. Fifty-three patients (30 males, 23 females) with known or suspected endocrine tumours were studied. Clinical indications for somatostatin receptor (SSTR) scintigraphy (SPECT/CT image fusion) included staging of newly diagnosed tumours (n=14) and detection of unknown primary tumour in the presence of clinical and/or biochemical suspicion of neuroendocrine malignancy (n=20). Follow-up studies after therapy were performed in 19 patients. A mean activity of 400 MBq of 99m Tc-EDDA/HYNIC-Tyr 3 -octreotide was given intravenously. SPECT using a dual-detector scintillation camera and diagnostic multi-detector CT were sequentially performed. To ensure reproducible positioning, patients were fixed in an individualised vacuum mattress with modality-specific external markers for co-registration. SPECT and CT data were initially interpreted separately and the fused images were interpreted jointly in consensus by nuclear medicine and diagnostic radiology physicians. SPECT was true-positive (TP) in 18 patients, true-negative (TN) in 16, false-negative (FN) in ten and false-positive (FP) in nine; CT was TP in 18 patients, TN in 21, FP in ten and FN in four. With image fusion (SPECT and CT), the scan result was TP in 27 patients (50.9%), TN in 25 patients (47.2%) and FN in one patient, this FN result being caused by multiple small liver metastases; sensitivity was 95% and specificity, 100%. The difference between SPECT and SPECT/CT was statistically as significant as the difference between CT and SPECT/CT image fusion (P<0

  11. HMPAO-SPECT in cerebral seizures

    International Nuclear Information System (INIS)

    Gruenwald, F.; Bockisch, A.; Reichmann, K.; Ammari, B.; Hotze, A.; Biersack, H.J.; Durwen, H.; Buelau, P.; Elger, C.E.; Rohde, A.; Penin, H.

    1988-01-01

    In nine patients with suspected psychogenic seizures and in three patients with proven epileptic seizures HMPAO-SPECT was performed prior to and during seizure. In the patients with lateron-proven psychogenic seizures no, or only slight, changes of regional cerebral blood flow were found. Patients with proven epilepsy revealed partly normal findings interictally but during seizure a markedly increased circumscript blood flow was found in all patients. Even though PET is superior to SPECT with respect to spatial resolution, in the diagnosis of seizures HMPAO-SPECT has the advantage of enabling injection of the tracer during the seizure and the performance of the SPECT study subsequently. (orig.) [de

  12. SPECT of aged backache patients

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Shigehiko; Nishikimi, Junzo; Mizuno, Naokado; Watanabe, Kentaro; Kondo, Masaki; Ozaki, Satoshi; Urasaki, Tetsuya; Muro, Toshiyuki [Prefectural Tajimi Hospital, Gifu (Japan)

    1995-12-01

    Single photon emission computed tomography (SPECT) using {sup 99m}Tc-HMDP was performed on 53 middle-aged or elderly patients (male 20, female, 33; age range, 40-80 years old) with lumbago, i.e., 25 patients with lumbar spondylosis, 15 with lumbar degenerative spondylolisthesis, 4 with spondylolytic spondylolisthesis, 3 with compression fracture, 3 with pulurent spondylitis, 2 with spondylous osteoporosis, and 1 with spinal osteodesmosis. {sup 99m}Tc-HMDP (740 MBq) was intravenously injected and regular SPECT was performed at 3 hours. Gamma camera was performed for about 10 seconds with 5deg intervals, and 36 steps (180deg) of collection was completed after about 6 minutes. The radioisotope accumulation, the presence or absence of sthenia, and its site were evaluated. Forty-seven (88.7%) patients showed excessive accumulation, i.e., 40 (75.5%) in peripheral vertebral osteophyte, 31 (58.5%) in vertebral articulations, and 10 (18.9%) in whole vertebral body. Significantly increased bilateral excessive accumulation was admitted in the vertebral articulations of sliding disc in degenerative spondylolisthesis. SPECT is considered useful in understanding the pathophysiology of degenerative lumber diseases. (S.Y.).

  13. SPECT of aged backache patients

    International Nuclear Information System (INIS)

    Ito, Shigehiko; Nishikimi, Junzo; Mizuno, Naokado; Watanabe, Kentaro; Kondo, Masaki; Ozaki, Satoshi; Urasaki, Tetsuya; Muro, Toshiyuki

    1995-01-01

    Single photon emission computed tomography (SPECT) using 99m Tc-HMDP was performed on 53 middle-aged or elderly patients (male 20, female, 33; age range, 40-80 years old) with lumbago, i.e., 25 patients with lumbar spondylosis, 15 with lumbar degenerative spondylolisthesis, 4 with spondylolytic spondylolisthesis, 3 with compression fracture, 3 with pulurent spondylitis, 2 with spondylous osteoporosis, and 1 with spinal osteodesmosis. 99m Tc-HMDP (740 MBq) was intravenously injected and regular SPECT was performed at 3 hours. Gamma camera was performed for about 10 seconds with 5deg intervals, and 36 steps (180deg) of collection was completed after about 6 minutes. The radioisotope accumulation, the presence or absence of sthenia, and its site were evaluated. Forty-seven (88.7%) patients showed excessive accumulation, i.e., 40 (75.5%) in peripheral vertebral osteophyte, 31 (58.5%) in vertebral articulations, and 10 (18.9%) in whole vertebral body. Significantly increased bilateral excessive accumulation was admitted in the vertebral articulations of sliding disc in degenerative spondylolisthesis. SPECT is considered useful in understanding the pathophysiology of degenerative lumber diseases. (S.Y.)

  14. Labeled receptor ligands for spect

    International Nuclear Information System (INIS)

    Kung, H.F.

    1989-01-01

    Receptor specific imaging agents for single photon emission computed tomography (SPECT) can potentially be useful in the understanding of basic biochemistry and pharmacology of receptors. SPECT images may also provide tools for evaluation of density and binding kinetics of a specific receptor, information important for diagnosis and patient management. Basic requirements for receptor imaging agents are: (a) they are labeled with short-lived isotopes, (b) they show high selectivity and specific uptake, (c) they exhibit high target/background ratio, and (d) they can be modeled to obtain quantitative information. Several good examples of CNS receptor specific ligands labeled with I-123 have been developed, including iodoQNB, iodoestrogen iodobenzadiazepine, iodobenazepine, iodobenzamides for muscarinic, estrogen benzadiazepine, D-1 and D-2 dopamine receptors. With the advent of newer and faster SPECT imaging devices, it may be feasible to quantitate the receptor density by in vivo imaging techniques. These new brain imaging agents can provide unique diagnostic information, which may not be available through other imaging modalities, such as CT and MRI

  15. Gallium-67 scintiscanning of the lungs of AIDS patients

    International Nuclear Information System (INIS)

    Tatsch, K.; Knesewitsch, P.; Kirsch, C.M.; Kueffer, G.; Doerner, G.; Goebel, F.D.

    1988-01-01

    Thirty patients suffering from AIDS have been examined in this study. The stage of infection of the patients was defined according to the criteria of the Center for Disease Control, so that the study covered 22 patients with manifest AIDS, and 8 patients with AIDS-related complex. The lung scans have been made in all patients 48 and 72 hours after i.v. injection of 185 MBq of 67 Ga citrate, taking ventral and dorsal images with the gamma camera. In the scans recorded after 72 hours, ROI technique has been used to quantify the lung uptake and to put it in relation to uptake data of the soft neck tissue. The results show that gallium scintiscanning is far more sensitive in detecting opportunistic pneumonia in AIDS patients than is conventional chest radiography. If the latter detected any signs at all, the gallium scan did so about one to two weeks earlier in about one third of the patients. Pathologic accumulation in the scintiscan exceeding the range shown by the correlated radiograph indicate that in single cases extension of pneumonia can be underestimated when assessed by the radiograph alone. (orig./MG) [de

  16. Comparison between high-resolution computed tomography and 99mTc-technegas SPECT pulmonary emphysema

    International Nuclear Information System (INIS)

    Nakano, Satoru; Satoh, Katashi; Takahashi, Kazue

    1996-01-01

    Scintigraphy with 99m Tc-technegas was recently introduced for clinical imaging of lung ventilation. This method has been found to be useful in emergencies, to be more suitable for single photon emission computed tomography (SPECT) than other agents used in ventilation scintigraphy, and could reveal abnormalities in ventilation more easily than high resolution computed tomography (HRCT) in pulmonary emphysema. We compared 99m Tc-technegas SPECT with HRCT in six regions: the right upper, middle, and lower lobes, the left upper lobe, the lingula, and the left lower lobe, in 15 patients with pulmonary emphysema. Patients with centrilobular emphysema tended to show stronger changes in upper lobes than in lower lobes on both 99m Tc-technegas SPECT and HRCT. Some regions showed no change on HRCT but various changes on 99m Tc-SPECT. Patients with panlobular emphysema showed severe changes on 99m Tc-SPECT in lower lung fields in which well-demarcated areas of low attenuation were not seen on HRCT. We conclude that 99m Tc-SPECT is useful for detecting early changes and panlobular changes in pulmonary emphysema. (author)

  17. Are there any determinants of interictal brain SPECT perfusion change in unilateral hippocampal sclerosis?

    International Nuclear Information System (INIS)

    Tepmongkol, S.; Locharernkul, C.; Lerdlum, S.

    2005-01-01

    In localizing ictal onset during pre-surgical evaluation, interictal brain SPECT has been used to determine baseline brain abnormalities in order to compare with ictal SPECT. However, in some patients with hippocampal sclerosis (HS), no baseline perfusion abnormality is seen. In this subgroup of patients, performing interictal SPECT may be considered unnecessary. This study is aimed at determining the factors that may influence the interictal SPECT perfusion change in unilateral HS. Forty-one unilateral HS patients (21 males, 20 females; age 30.3±8.0 years) who had interictal brain perfusion SPECT (more than 24 hours after the seizure) were enrolled. Multiple factors i.e. age, sex, age of epilepsy onset, duration of epilepsy, presence of aura, clinical lateralization, interictal EEG lateralization, and ictal EEG lateralization were used as independent variables to predict hypoperfusion of the temporal lobe ipsilateral to hippocampal sclerosis detected on MRI. Ipsilateral temporal hypoperfusion were observed in 18/41 (43.9%) patients. None of these factors showed significant correlation to the perfusion changes. It was also concluded that age, sex, age of epilepsy onset, duration of epilepsy, presence of aura, clinical lateralization, interictal EEG lateralization, and ictal EEG lateralization cannot be used to predict interictal SPECT perfusion changes at the hippocampal sclerosis region. (author)

  18. N-isopropyl I-123 p-iodoamphetamine (IMP) brain SPECT in dementia

    International Nuclear Information System (INIS)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Yoshikawa, Kohki; Ohtake, Tohru; Watanabe, Toshiaki; Iwata, Makoto; Shimizu, Teruo; Iio, Masahiro

    1988-01-01

    Six patients of Alzheimer's disease (AD), two patients of Pick disease (PD) and two patients of Creutzfeldt-Jakob disease (CJD) were studied with N-Isopropyl I-123 p-Iodoamphetamine (IMP) with SPECT. The pattern of IMP uptake in these demented groups were compared with that in five agematched normal controls and correlated with MRI and XCT. In all AD cases, SPECT revealed focal reduction of IMP uptake in frontal (6/6), parietal (6/6) and temporal (6/6) cortex, although MRI and XCT were normal. In both PD case, SPECT showed focal reduction of IMP uptake in frontal (1/2) and temporal (2/2) cortex with moderate labor atrophy on MRI and XCT. In both CJD case, SPECT showed diffuse reduction of IMP uptake in cerebral cortex in spite of no abnormality on MRI and XCT. These findings suggest that SPECT can detect earlier diseased process of AD and CJD than MRI or XCT and that SPECT may be helpful for the differential diagnosis of non-vascular dementia. (author)

  19. N-isopropyl I-123 p-iodoamphetamine (IMP) brain SPECT in dementia

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Toshimitsu; Kosaka, Noboru; Nishikawa, Junichi; Yoshikawa, Kohki; Ohtake, Tohru; Watanabe, Toshiaki; Iwata, Makoto; Shimizu, Teruo; Iio, Masahiro

    1988-12-01

    Six patients of Alzheimer's disease (AD), two patients of Pick disease (PD) and two patients of Creutzfeldt-Jakob disease (CJD) were studied with N-Isopropyl I-123 p-Iodoamphetamine (IMP) with SPECT. The pattern of IMP uptake in these demented groups were compared with that in five agematched normal controls and correlated with MRI and XCT. In all AD cases, SPECT revealed focal reduction of IMP uptake in frontal (6/6), parietal (6/6) and temporal (6/6) cortex, although MRI and XCT were normal. In both PD case, SPECT showed focal reduction of IMP uptake in frontal (1/2) and temporal (2/2) cortex with moderate labor atrophy on MRI and XCT. In both CJD case, SPECT showed diffuse reduction of IMP uptake in cerebral cortex in spite of no abnormality on MRI and XCT. These findings suggest that SPECT can detect earlier diseased process of AD and CJD than MRI or XCT and that SPECT may be helpful for the differential diagnosis of non-vascular dementia.

  20. Clinical usefulness of hyperventilation-loaded SPECT in coronary artery disease

    International Nuclear Information System (INIS)

    Taya, Makoto

    1994-01-01

    The purpose of this study was twofold: (1) to assess the clinical usefulness of hyperventilation-loaded Tl-201 myocardial single photon emission computed tomography (HV-SPECT) in detecting coronary spasm; and (2) to correlate coronary spasm with ischemic heart diseases. A total of 138 patients were examined. They were divided into Group 1 of a total of 69 patients with chest pain at rest, consisting of 25 with vasospastic angina and 44 with atypical chest pain; Group 2 of 37 patients with angina pectoris; and Group 3 of 32 patients with myocardial infarction. In Group I, HV-SPECT was positive in 96% (24/25) for vasospastic angina and 50% (22/44) for atypical angina pectoris. When thallium defect scores 2 or more were interpreted as a decreased thallium uptake, Tl-201 HV-SPECT had a sensitivity of 72%, a specificity of 93%, and an accuracy of 85.6% in diagnosing vasospastic angina. In Group 2, HV-SPECT showed a significantly higher positive rate in patients with resting angina pectoris than those with effort angina pectoris (69% vs 22%). In Group 3, HV-SPECT was a positive rate of 53%. When Nifedipine was administered, the positive cases turned to be negative in 47%. HV-SPECT proved to be useful as a noninvasive method for diagnosing coronary spasm. Coronary spasm was suggested to be present in ischemic heart disease other than vasospastic angina and atypical chest pain. (N.K.)

  1. Filters in 2D and 3D Cardiac SPECT Image Processing

    Directory of Open Access Journals (Sweden)

    Maria Lyra

    2014-01-01

    Full Text Available Nuclear cardiac imaging is a noninvasive, sensitive method providing information on cardiac structure and physiology. Single photon emission tomography (SPECT evaluates myocardial perfusion, viability, and function and is widely used in clinical routine. The quality of the tomographic image is a key for accurate diagnosis. Image filtering, a mathematical processing, compensates for loss of detail in an image while reducing image noise, and it can improve the image resolution and limit the degradation of the image. SPECT images are then reconstructed, either by filter back projection (FBP analytical technique or iteratively, by algebraic methods. The aim of this study is to review filters in cardiac 2D, 3D, and 4D SPECT applications and how these affect the image quality mirroring the diagnostic accuracy of SPECT images. Several filters, including the Hanning, Butterworth, and Parzen filters, were evaluated in combination with the two reconstruction methods as well as with a specified MatLab program. Results showed that for both 3D and 4D cardiac SPECT the Butterworth filter, for different critical frequencies and orders, produced the best results. Between the two reconstruction methods, the iterative one might be more appropriate for cardiac SPECT, since it improves lesion detectability due to the significant improvement of image contrast.

  2. The current status of SPECT or SPECT/CT in South Korea

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Ik Dong; Choi, Eun Kyung; Chung, Yong An [Dept. of Radiology, Incheon Saint Mary' s HospitalThe Catholic University of Korea, Incheon (Korea, Republic of)

    2017-06-15

    The first step to nuclear medicine in Korea started with introduction of the gamma camera in 1969. Although planar images with the gamma camera give important functional information, they have the limitations that result from 2-dimensional images. Single-photon emission computed tomography (SPECT) due to its 3-dimensional image acquisition is superior to earlier planar gamma imaging in image resolution and diagnostic accuracy. As demand for a hybrid functional and anatomical imaging device has increased, integrated SPECT/CT systems have been used. In Korea, SPECT/CT was for the first time installed in 2003. SPECT/CT can eliminate many possible pitfalls on SPECT-alone images, making better attenuation correction and thereby improving image quality. Therefore, SPECT/CT is clinically preferred in many hospitals in various aspects. More recently, additional SPECT/CT images taken from the region with equivocal uptake on planar images have been helpful in making precise interpretation as part of their clinical workup in postoperative thyroid cancer patients. SPECT and SPECT/CT have various advantages, but its clinical application has gradually decreased in recent few years. While some researchers investigated the myocardial blood flow with cardiac PET using F-18 FDG or N-13 ammonia, myocardial perfusion SPECT is, at present, the radionuclide imaging study of choice for the risk stratification and guiding therapy in the coronary artery disease patients in Korea. New diagnostic radiopharmaceuticals for AD have received increasing attention; nevertheless, brain SPECT will remain the most reliable modality evaluating cerebral perfusion.

  3. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation

    International Nuclear Information System (INIS)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E.

    2005-01-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis

  4. Thermodynamic and transport properties of liquid gallium

    International Nuclear Information System (INIS)

    Park, H.Y.; Jhon, M.S.

    1982-01-01

    The significant structure theory of liquids has been successfully applied to liquid gallium. In this work, we have assumed that two structures exist simultaneously in liquid gallium. One is considerec as loosely close packed β-Ga-like structure and the other is remainder of solid α-Ga or α-Ga-like structure. This two structural model is introduced to construct the liquid partition function. Using the partition function, the thermodynamic and transport properties are calculated ever a wide temperature range. The calculated results are quite satisfactory when compared with the experimental results. (Author)

  5. Gallium uptake in myositis ossificans. Potential pitfalls in diagnosis

    International Nuclear Information System (INIS)

    Salzman, L.; Lee, V.W.; Grant, P.

    1987-01-01

    Seven cases of gallium uptake in myositis ossificans are described. Gallium scans are done frequently in paraplegics, quadriplegics, and comatose patients to look for occult infection. It is important to be aware of possible gallium uptake in myositis ossificans, particularly in the extremities, which is frequent in these patients. Gallium uptake may be present prior to any abnormalities seen on plain films or CT scans. It is important to correlate roentgenograms with abnormal gallium scans, particularly in the extremities, to avoid potential pitfalls in diagnosis and prevent unnecessary antibiotic treatment. A bone scan should be obtained whenever possible, particularly when roentgenograms are negative, to confirm the diagnosis

  6. 67Gallium lung scans in progressive systemic sclerosis

    International Nuclear Information System (INIS)

    Baron, M.; Feiglin, D.; Hyland, R.; Urowitz, M.B.; Shiff, B.

    1983-01-01

    67 Gallium lung scans were performed in 19 patients with progressive systemic sclerosis (scleroderma). Results were expressed quantitatively as the 67 Gallium Uptake Index. The mean total pulmonary 67 Gallium Uptake Index in patients was significantly higher than that in controls (41 versus 25), and 4 patients (21%) fell outside the normal range. There were no clinical or laboratory variables that correlated with the 56 Gallium uptake. Increased pulmonary 67 Gallium uptake in scleroderma may prove useful as an index of pulmonary disease activity

  7. Brain MRI and SPECT in the diagnosis of early neurological involvement in Wilson's disease

    International Nuclear Information System (INIS)

    Piga, Mario; Satta, Loredana; Serra, Alessandra; Loi, Gianluigi; Murru, Alessandra; Demelia, Luigi; Sias, Alessandro; Marrosu, Francesco

    2008-01-01

    To evaluate the impact of brain MRI and single-photon emission computed tomography (SPECT) in early detection of central nervous system abnormalities in patients affected by Wilson's disease (WD) with or without neurological involvement. Out of 25 consecutive WD patients, 13 showed hepatic involvement, ten hepatic and neurological manifestations, and twp hepatic, neurological, and psychiatric symptoms, including mainly movement disorders, major depression, and psychosis. Twenty-four healthy, age-gender matched subjects served as controls. All patients underwent brain MRI and 99m Tc-ethyl-cysteinate dimer (ECD) SPECT before starting specific therapy. Voxel-by-voxel analyses were performed using statistical parametric mapping to compare differences in 99m Tc-ECD brain uptake between the two groups. Brain MRI showed T2-weighted hyperintensities in seven patients (28%), six of whom were affected by hepatic and neurological forms. Brain perfusion SPECT showed pathological data in 19 patients (76%), revealing diffuse or focal hypoperfusion in superior frontal (Brodmann area (BA) 6), prefrontal (BA 9), parietal (BA 40), and occipital (BA 18, BA 39) cortices in temporal gyri (BA 37, BA 21) and in caudatus and putamen. Moreover, hepatic involvement was detected in nine subjects; eight presented both hepatic and neurological signs, while two exhibited WD-correlated hepatic, neurological, and psychiatric alterations. All but one patient with abnormal MRI matched with abnormal ECD SPECT. Pathologic MRI findings were obtained in six out of ten patients with hepatic and neurological involvement while abnormal ECD SPECT was revealed in eight patients. Both patients with hepatic, neurological, and psychiatric involvement displayed abnormal ECD SPECT and one displayed an altered MRI. These findings suggest that ECD SPECT might be useful in detecting early brain damage in WD, not only in the perspective of assessing and treating motor impairment but also in evaluating better the

  8. SPECT/CT in gingival squamous cell carcinoma

    International Nuclear Information System (INIS)

    Nikolova, R.; Hadzhiyska, V.; Petrov, T.

    2015-01-01

    Gingival squamous cell carcinoma have a relatively poor prognosis and large differential diagnosis (periodontitis, osteomyelitis, etc.), therefore, it is usually diagnosed at a late stage. Hematogenous dissemination occurs in only about 10% of cases, including lung (66%), bone (22%), liver (10%), skin, bone marrow and mediastinum. Bone metastases are very rare compared to other malignancies, most commonly affect the axial skeleton (spine, pelvis, ribs and lumbar spine). In our case, we presented a patient with gingival squamous cell carcinoma and bone metastasis in the forearm detected with Whole Body Bone Scintigraphy (WBS), combined with Single Photon Emission Tomography /Computed Tomography (SPECT /CT). The obtained data suggest that the single use of WBS was not informative enough for making the final diagnosis, but the result of combined functional-morphological approach was the most pathognomonic. Thus, with single study can be obtained a complex information, which leads to a fast therapeutic decision. Key words: SPECT/CT. GINGiVAL. SQUAMOUS CELL CARCINOMA

  9. EDXRF and TXRF determination of gallium in gallium-uranium matrix

    International Nuclear Information System (INIS)

    Misra, N.L.; Sanjay Kumar, S.; Dhara, Sangita; Aggarwal, S.K.; Venugopal, V.

    2009-01-01

    Energy Dispersive X-Ray Fluorescence (EDXRF) and Total Reflection X-ray Fluorescence (TXRF) methods for determination of Gallium in Gallium-Uranium matrix have been developed. For EDXRF determinations, 200 μL of standards/samples mixed with internal standard copper were dispersed on 30 mm diameter absorbent sheet so that it behaves like a thin film of the sample. The Gallium amounts in samples were determined from their EDXRF spectra using a calibration plot. For TXRF determinations, samples were taken on flat polished quartz sample supports and Gallium was determined in conventional way. For EDXRF and TXRF determinations, the average precision and accuracy obtained for Ga determinations was better than 3% (1σ). (author)

  10. Two-Dimensional Modeling of Aluminum Gallium Nitride/Gallium Nitride High Electron Mobility Transistor

    National Research Council Canada - National Science Library

    Holmes, Kenneth

    2002-01-01

    Gallium Nitride (GaN) High Electron Mobility Transistors (HEMT's) are microwave power devices that have the performance characteristics to improve the capabilities of current and future Navy radar and communication systems...

  11. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  12. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  13. Application of extraction of gallium molybdotungstate HPA for their investigation in solutions and gallium determination

    International Nuclear Information System (INIS)

    Kol'tsova, E.G.; Vakulich, A.N.; Tsyganok, L.P.

    2001-01-01

    Extraction of gallium molybdotungstate heteropolyacids and their associates with a row of triphenylmethane dyes, use of extraction for study of complexing in Mo 6 -W 6 -Ga 3+ -H 3 O + system are investigated. Research of optimal analytical states and development of extraction spectrophotometric methods of gallium determination are done. It is shown that increase of Mo 6 part in heteropolyanion improves solvation interaction of heteropolyacids with organic solvents elevating extraction properties of polyanion [ru

  14. Superimposed dual-isotope SPECT using 99mTc-hydroxymethylene diphosphonate and 201Tl-chloride to assess cartilage invasion in laryngohypopharyngeal cancer

    International Nuclear Information System (INIS)

    Nishiyama, Yoshihiro; Yamamoto, Yuka; Yokoe, Koiku; Miyabe, Kazunori; Iwasaki, Takanobu; Toyama, Yoshihiro; Satoh, Katashi; Ohkawa, Motoomi

    2004-01-01

    Cartilage invasion in laryngohypopharyngeal cancer has a significant impact on the choice of treatment modality and outcome of the disease. We examined invasion of cartilage in laryngohypopharyngeal cancer by simultaneous bone and tumor dual-isotope SPECT using 99m Tc-hydroxymethylene diphosphonate and 201 Tl-chloride. Early and delayed simultaneous bone and tumor dual-isotope SPECT were performed on 19 patients with laryngohypopharyngeal cancer. Dual-isotope SPECT images were superimposed to project tumor location from tumor SPECT onto the osseous structures shown by bone SPECT. The presence or absence of cartilage invasion was evaluated histopathologically or by radiological studies such as CT and/or MRI. Histopathological or radiological examination of the cartilage revealed invasion in 5 patients and no invasion in 14 patients. The results of both early and delayed dual-isotope SPECT were exactly the same. Using dual-isotope SPECT, the sensitivity, specificity, and accuracy in detecting cartilage invasion by laryngohypopharyngeal cancer were: 80% (4/5), 92.9% (13/14), and 89.5% (17/19), respectively. Results of the present study suggest that superimposed early bone and tumor dual-isotope SPECT images may be sufficient for the diagnostic evaluation of cartilage invasion by laryngohypopharyngeal cancer. Superimposed dual-isotope SPECT imaging is a useful technique in the evaluation of cartilage invasion in laryngohypopharyngeal cancer. (author)

  15. [Performance of Thallium 201 rest-redistribution spect to predict viability in recent myocardial infarction].

    Science.gov (United States)

    Coll, Claudia; González, Patricio; Massardo, Teresa; Sierralta, Paulina; Humeres, Pamela; Jofré, Josefina; Yovanovich, Jorge; Aramburú, Ivonne; Brugère, Solange; Chamorro, Hernán; Ramírez, Alfredo; Kunstmann, Sonia; López, Héctor

    2002-03-01

    The detection of viability after acute myocardial infarction is primordial to select the most appropriate therapy, to decrease cardiac events and abnormal remodeling. Thallium201 SPECT is one of the radionuclide techniques used to detect viability. To evaluate the use of Thallium201 rest-redistribution SPECT to detect myocardial viability in reperfused patients after a recent myocardial infarction. Forty one patients with up to of 24 days of evolution of a myocardial infarction were studied. All had angiographically demonstrated coronary artery disease and were subjected to a successful thrombolysis, angioplasty or bypass grafting. SPECT Thallium201 images were acquired at rest and after 4 h of redistribution. These results were compared with variations in wall motion score, studied at baseline and after 3 or 4 months with echocardiography. The sensitivity of rest-redistribution Thallium201 SPECT, to predict recovery of wall motion was 91% when patient analysis was performed and 79% when segmental analysis was done in the culprit region. The figures for specificity were 56 and 73% respectively. Rest-distribution Thallium201 SPECT has an excellent sensitivity to predict myocardial viability in recent myocardial infarction. The data obtained in this study is similar to that reported for chronic coronary artery disease.

  16. 201Tl myocardial SPECT and β-endorphin levels in patients with suspected silent ischemia

    International Nuclear Information System (INIS)

    Lind, P.; Binter, G.; Koeltringer, P.; Eber, O.; Eber, B.; Klein, W.; Brandt, D.

    1990-01-01

    Today silent myocardial ischemia (SMI) is a well-recognized phenomenon. Treadmill exercise according to the Bruce protocol, 201 Tl myocardial SPECT and coronary angiography were performed in a total of 106 patients with suspected SMI. In group I (high probability of ischemia; n=46), reversible defects detected by SPECT correlated well with significant stenoses and irreversible defects with subtotal stenoses or complete occlusions. SPECT sensitivity in the detection of ischemia was 91%, its specificity 96%. In group II (low probability of ischemia; n=60), SPECT sensitivity was as high as in group I (94%) but due to a high number of false-positive results (e.g. cardiomyopathy) specificity was only 75%. However, SPECT was superior to exercise ECG (sensitivity 70%; specificity 56%) in the detection of SMI. In addition, β-endorphin levels were determined in 180 healthy subjects, 37 patients with symptomatic CAD and in 34 patients with SMI before and during maximum exercise. Exercise values in patients with SMI were significantly higher than in healthy subjects or in patients with symptomatic CAD. (orig./MG) [de

  17. The role of gallium-67 in Hodgkin's disease

    International Nuclear Information System (INIS)

    Bogart, Jeffrey A.; Chung, T. Chung; Mariados, Neil F.

    1996-01-01

    Purpose/Objective: Although widely used, the value of gallium imaging in managing Hodgkin's lymphoma remains unclear. Methods: Retrospective review of gallium and treatment data in patients with Hodgkin's disease between January 1990 and July 1995. Results: Eighty-six of 101 patients had Ga-67 imaging. Stage was as follows: 1A-11 patients, 1B - 2, 2A - 27, 2B - 22, 3A - 10, 3B - 5, 4A - 3 and 4B - 6. Sixty-two patients had staging gallium scans and 15% of tumors were not gallium avid. Two patients were upstaged based on gallium scan. Five patients had positive laparotomy and all had negative abdominal gallium exams. Three studies had false positive lesions. Initial therapy was assessed with gallium in 61 patients and 45 had complete response. Tumor recurred in 36% ((10(28))) of patients gallium negative after 3-6 cycles of chemotherapy, with no recurrences in 17 patients gallium negative after radiotherapy or chemo radiation. Six of 7 patients with focal gallium uptake after chemotherapy received radiotherapy and all remain disease free. Seven patients had persistent or progressive gallium-avid tumor after chemotherapy correlating with clinical disease. Two patients had false positive exams after radiotherapy. Twenty-two patients had gallium scans at recurrence. One scan was (false) negative and in two cases, gallium imaging was the initial evidence of recurrent tumor. Conclusion: Ga-67 imaging may help confirm the presence of active Hodgkin's disease, but was unreliable in defining disease remission after chemotherapy in this study population. Prospective studies may help define the role of gallium scans

  18. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  19. Brain imaging during seizure: ictal brain SPECT

    International Nuclear Information System (INIS)

    Kottamasu, Sambasiva Rao

    1997-01-01

    The role of single photon computed tomography (SPECT) in presurgical localization of medically intractable complex partial epilepsy (CPE) in children is reviewed. 99m Technetium neurolite, a newer lipophylic agent with a high first pass brain extraction and little or no redistribution is injected during a seizure, while the child is monitored with a video recording and continuous EEG and SPECT imaging is performed in the next 1-3 hours with the images representing regional cerebral profusion at the time of injection. On SPECT studies performed with radiopharmaceutical injected during a seizure, ictal focus is generally hypervascular. Other findings on ictal brain SPECT include hypoperfusion of adjacent cerebral cortex and white matter, hyperperfusion of contralateral motor cortex, hyperperfusion of ipsilateral basal ganglia and thalamus, brain stem and contralateral cerebellum. Ictal brain SPECT is non-invasive, cost effective and highly sensitive for localization of epileptic focus in patients with intractable CPE. (author)

  20. Mnemonic activation by SPECT; Activation mnesique en TEMP

    Energy Technology Data Exchange (ETDEWEB)

    Migneco, O.; Darcourt, J.; Benoit, M; Malandain, G.; Thirion, J.P.; Robert, Ph.; Vidal, R.; Desvignes, Ph.; Benoliel, J.; Ayache, N.; Bussiere, F. [Universite de Nice Sophia-Antipolis, INRIA (France)

    1997-12-31

    Data of literature show that SPECT is able to detect cerebral activations induced by sensory-motor stimuli. The facts are not clearly established in what concerns the cognitive activations the amplitude of which is lower. We have studied an activation paradigm such as the Grober and Bruschke test which implies the long term explicit memory. It comprises a visual presentation of words followed by their indexed recall. By using a two-day protocol, 2 SPECTs were achieved in 4 healthy right-handed voluntaries as follows: one of activation (A) and one of control (B). The fifth subject benefited by a SPECT B and of an MRI. The injection for the examination A has been done during the indexed recall stage and for the examination B at the moment when the patient repeated several times the same 3 words. The SPECT data were collected 1 hour after the injection of 370 MBq of ECD making use of a 3-head camera equipped with UHR fan collimators and ending by a LMH on the reconstructed images of 8 mm. The MRI has been achieved by means of a Signa 1.5 Tesla magnet. The SPECT A and B of the subjects 1 to 4 were matched elastically to that of the subject 5 and that of the subject 5 was rigidly matched on its MRI. In this way the individual activation cards of the 4 subjects could be averaged and superimposed on the MRI of the 5. subject. One observes an internal temporal activation (maximal activation of left tonsil, +25% and right uncus, +23%) and a right cingulum activation (maximal activation, +25%), in agreement with the neuro-physiological data. The elastic matching makes possible the inter-subject averaging, what increases the signal-to-noise ratio of activation. The inter-modality rigid matching facilitates the anatomical localisation of the activation site. With these adapted tools, the cognitive activation is thus possible by SPECT and opens perspectives for early diagnosis of neurological troubles, namely of Alzheimer`s disease

  1. Long-chain amine-templated synthesis of gallium sulfide and gallium selenide nanotubes

    Science.gov (United States)

    Seral-Ascaso, A.; Metel, S.; Pokle, A.; Backes, C.; Zhang, C. J.; Nerl, H. C.; Rode, K.; Berner, N. C.; Downing, C.; McEvoy, N.; Muñoz, E.; Harvey, A.; Gholamvand, Z.; Duesberg, G. S.; Coleman, J. N.; Nicolosi, V.

    2016-06-01

    We describe the soft chemistry synthesis of amine-templated gallium chalcogenide nanotubes through the reaction of gallium(iii) acetylacetonate and the chalcogen (sulfur, selenium) using a mixture of long-chain amines (hexadecylamine and dodecylamine) as a solvent. Beyond their role as solvent, the amines also act as a template, directing the growth of discrete units with a one-dimensional multilayer tubular nanostructure. These new materials, which broaden the family of amine-stabilized gallium chalcogenides, can be tentatively classified as direct large band gap semiconductors. Their preliminary performance as active material for electrodes in lithium ion batteries has also been tested, demonstrating great potential in energy storage field even without optimization.We describe the soft chemistry synthesis of amine-templated gallium chalcogenide nanotubes through the reaction of gallium(iii) acetylacetonate and the chalcogen (sulfur, selenium) using a mixture of long-chain amines (hexadecylamine and dodecylamine) as a solvent. Beyond their role as solvent, the amines also act as a template, directing the growth of discrete units with a one-dimensional multilayer tubular nanostructure. These new materials, which broaden the family of amine-stabilized gallium chalcogenides, can be tentatively classified as direct large band gap semiconductors. Their preliminary performance as active material for electrodes in lithium ion batteries has also been tested, demonstrating great potential in energy storage field even without optimization. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr01663d

  2. Clinical utility of SPECT neuroimaging in the diagnosis and treatment of traumatic brain injury: a systematic review.

    Directory of Open Access Journals (Sweden)

    Cyrus A Raji

    Full Text Available PURPOSE: This systematic review evaluated the clinical utility of single photon emission computed tomography (SPECT in traumatic brain injury (TBI. METHODS: After defining a PICO Statement (Population, Intervention, Comparison and Outcome Statement, PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria were applied to identify 1600 articles. After screening, 374 articles were eligible for review. Inclusion for review was focus on SPECT in the setting of mild, moderate, or severe TBI with cerebral lobar specificity of SPECT findings. Other inclusion criteria were comparison modalities in the same subjects and articles in English. Foreign language articles, SPECT studies that did not include comparison modalities, and case reports were not included for review. RESULTS: We identified 19 longitudinal and 52 cross-sectional studies meeting inclusion criteria. Three longitudinal studies examined diagnostic predictive value. The first showed positive predictive value increases from initial SPECT scan shortly after trauma to one year follow up scans, from 59% to 95%. Subsequent work replicated these results in a larger cohort. Longitudinal and cross sectional studies demonstrated SPECT lesion localization not detected by CT or MRI. The most commonly abnormal regions revealed by SPECT in cross-sectional studies were frontal (94% and temporal (77% lobes. SPECT was found to outperform both CT and MRI in both acute and chronic imaging of TBI, particularly mild TBI. It was also found to have a near 100% negative predictive value. CONCLUSIONS: This review demonstrates Level IIA evidence (at least one non-randomized controlled trial for the value of SPECT in TBI. Given its advantages over CT and MRI in the detection of mild TBI in numerous studies of adequate quality, and given its excellent negative predictive value, it may be an important second test in settings where CT or MRI are negative after a closed head injury with post

  3. Clinical utility of SPECT neuroimaging in the diagnosis and treatment of traumatic brain injury: a systematic review.

    Science.gov (United States)

    Raji, Cyrus A; Tarzwell, Robert; Pavel, Dan; Schneider, Howard; Uszler, Michael; Thornton, John; van Lierop, Muriel; Cohen, Phil; Amen, Daniel G; Henderson, Theodore

    2014-01-01

    This systematic review evaluated the clinical utility of single photon emission computed tomography (SPECT) in traumatic brain injury (TBI). After defining a PICO Statement (Population, Intervention, Comparison and Outcome Statement), PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) criteria were applied to identify 1600 articles. After screening, 374 articles were eligible for review. Inclusion for review was focus on SPECT in the setting of mild, moderate, or severe TBI with cerebral lobar specificity of SPECT findings. Other inclusion criteria were comparison modalities in the same subjects and articles in English. Foreign language articles, SPECT studies that did not include comparison modalities, and case reports were not included for review. We identified 19 longitudinal and 52 cross-sectional studies meeting inclusion criteria. Three longitudinal studies examined diagnostic predictive value. The first showed positive predictive value increases from initial SPECT scan shortly after trauma to one year follow up scans, from 59% to 95%. Subsequent work replicated these results in a larger cohort. Longitudinal and cross sectional studies demonstrated SPECT lesion localization not detected by CT or MRI. The most commonly abnormal regions revealed by SPECT in cross-sectional studies were frontal (94%) and temporal (77%) lobes. SPECT was found to outperform both CT and MRI in both acute and chronic imaging of TBI, particularly mild TBI. It was also found to have a near 100% negative predictive value. This review demonstrates Level IIA evidence (at least one non-randomized controlled trial) for the value of SPECT in TBI. Given its advantages over CT and MRI in the detection of mild TBI in numerous studies of adequate quality, and given its excellent negative predictive value, it may be an important second test in settings where CT or MRI are negative after a closed head injury with post-injury neurological or psychiatric symptoms.

  4. Value of gallium 67 citrate scintigraphy in ophthalmology

    International Nuclear Information System (INIS)

    Ivanez-Alloschery, Monique.

    1978-01-01

    For ophthalmologists scintigraphy appears as a simple method to detect endoocular or endoorbital abnormalities. However none of the many scintigraphic methods described seems reliable enough to be used alone. One of the latest isotopic explorations using gallium 67 citrate, a tracer considered tumour-tropic might be able to solve this problem. The aim of this work is to judge the value of the method in the diagnosis of malignant endoocular and endoorbital tumours on the basis of 24 anatomoclinical observations. It may be concluded from this study that ocular gallium 67 citrate scintigraphy, which gave no clearly positive results at all but some doubtful results in the case of endoocular tumours more than 5 mm in diameter, is to be rejected; fluorescein angiography and ocular echograhy provide more elements for an accurate etiological diagnosis. Orbital scintigraphy on the other hand seems to be a necessary complement to a tomodensitometric examination since both methods offer diagnostic information without systematic recurse to carotid arteriography or orbital phlebography, sometimes dangerous for the patient [fr

  5. Optical characteristics of a gallium laser plasma

    International Nuclear Information System (INIS)

    Shuaibov, A.K.; Shimon, L.L.; Dashchenko, A.I.; Shevera, I.V.; Chuchman, M.P.

    2001-01-01

    Results are presented from studies of the emission from an erosion gallium laser plasma at a moderate intensity (W = (1-5) x 10 8 W/cm 2 ) of a 1.06-μm laser radiation. It is shown that, under these conditions, the lower excited states of gallium atoms are populated most efficiently. Among the ions, only the most intense GaII lines are observed in the emission spectrum. The populations of GaI and GaII excited states are not related to direct electron excitation, but are determined by the recombination of gallium ions with slow electrons. The recombination times of GaIII and GaII ions in the core of the plasma jet are determined from the waveforms of emission in the GaII and GaI spectral lines and are equal to 10 and 140 ns, respectively. The results obtained are of interest for spectroscopic diagnostics of an erosion plasma produced from gallium-containing layered crystals during the laser deposition of thin films

  6. Gallium-positive Lyme disease myocarditis

    International Nuclear Information System (INIS)

    Alpert, L.I.; Welch, P.; Fisher, N.

    1985-01-01

    In the course of a work-up for fever of unknown origin associated with intermittent arrhythmias, a gallium scan was performed which revealed diffuse myocardial uptake. The diagnosis of Lyme disease myocarditis subsequently was confirmed by serologic titers. One month following recovery from the acute illness, the abnormal myocardial uptake completely resolved

  7. Comparison of SPECT/CT and MRI in diagnosing symptomatic lesions in ankle and foot pain patients: diagnostic performance and relation to lesion type.

    Science.gov (United States)

    Ha, Seunggyun; Hong, Sung Hwan; Paeng, Jin Chul; Lee, Dong Yeon; Cheon, Gi Jeong; Arya, Amitabh; Chung, June-Key; Lee, Dong Soo; Kang, Keon Wook

    2015-01-01

    The purpose of this study was to compare the diagnostic performance of SPECT/CT and MRI in patients with ankle and foot pain, with regard to the lesion types. Fifty consecutive patients with ankle and foot pain, who underwent 99mTc-MDP SPECT/CT and MRI, were retrospectively enrolled in this study. Symptomatic lesions were determined based on clinical examination and response to treatment. On MRI and SPECT/CT, detected lesions were classified as bone, ligament/tendon, and joint lesions. Uptake on SPECT/CT was assessed using a 4-grade system. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SPECT/CT and MRI were evaluated in all detected lesions and each lesion type. Diagnostic value of uptake grade was analyzed using receiver-operating characteristics (ROC) curve analysis, and diagnostic performance was compared using Chi-square or McNemar tests. In overall lesions, the sensitivity, PPV and NPV of SPECT/CT for symptomatic lesions were 93%, 56%, 91%, and they were 98%, 48%, 95% for MRI. There was no significant difference between SPECT/CT and MRI. However, the specificity of SPECT/CT was significantly higher than that of MRI (48% versus 24%, P = 0.016). Uptake grade on SPECT/CT was significantly higher in symptomatic lesions (P diagnostic performance for symptomatic lesions in ankle and foot pain patients. SPECT/CT and MRI exhibit different diagnostic specificity in different lesion types. SPECT/CT may be used as a complementary imaging method to MRI for enhancing diagnostic specificity.

  8. Quantitative Analysis of cardiac SPECT

    International Nuclear Information System (INIS)

    Nekolla, S.G.; Bengel, F.M.

    2004-01-01

    The quantitative analysis of myocardial SPECT images is a powerful tool to extract the highly specific radio tracer uptake in these studies. If compared to normal data bases, the uptake values can be calibrated on an individual basis. Doing so increases the reproducibility of the analysis substantially. Based on the development over the last three decades starting from planar scinitigraphy, this paper discusses the methods used today incorporating the changes due to tomographic image acquisitions. Finally, the limitations of these approaches as well as consequences from most recent hardware developments, commercial analysis packages and a wider view of the description of the left ventricle are discussed. (orig.)

  9. SPECT og PET i neurobiologien

    DEFF Research Database (Denmark)

    Paulson, O.B.; Lassen, N.A.

    1997-01-01

    PET (positron emission tomography) and SPECT (single photon emission computed tomography) are isotopic methods in which the distribution is registered of radiolabelled tracers given in such small amounts that they are without effect on the organism or the organism's disposal of them. Thus, a series...... of important biological processes in the intact organism can be studied. The methods have been used in many disciplines but in particular for neurobiological research on the brain--e.g., the brain's regional blood circulation and mapping of the brain's functional structure. The methods have also been used...

  10. Non invasive evaluation of the coronary atherosclerosis illness in patients with silent ischemia: utility of the SPECT of myocardial perfusion. Electric, angiographic and image correlation; Valoracion no invasiva de la enfermedad ateroesclerosa coronaria en pacientes con isquemia silente: utilidad del SPECT de perfusion miocardica. Correlacion electrica, angiografica y de imagen

    Energy Technology Data Exchange (ETDEWEB)

    Puente B, A.; Roffe G, F.; Aceves C, J.; Gomez A, E. [Hospital Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico)

    2005-07-01

    The objective of the work was to determine the utility of the SPECT (Single Photon Emission Computerized Tomography) of myocardial perfusion for the ischemia detection in asymptomatic patients with Coronary Atherosclerosis Illness. It was concluded that the SPECT of myocardial perfusion has a high sensitivity (97%) for the silent ischemia diagnosis.

  11. Evaluation of pelvic ring injuries using SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Scheyerer, Max J. [University Hospital Zurich, Division of Trauma Surgery, Department of Surgery, Zurich (Switzerland); University Medical Center, Centre for Orthopaedic and Trauma Surgery, Cologne (Germany); Huellner, Martin; Pietsch, Carsten [University Hospital Zurich, Division of Nuclear Medicine, Department of Medical Radiology, Zurich (Switzerland); Werner, Clement M.L. [University Hospital Zurich, Division of Trauma Surgery, Department of Surgery, Zurich (Switzerland); Veit-Haibach, Patrick [University Hospital Zurich, Division of Nuclear Medicine, Department of Medical Radiology, Zurich (Switzerland); University Hospital Zurich, Diagnostic and Interventional Radiology, Department of Medical Radiology, Zurich (Switzerland)

    2014-08-12

    The incidence of pelvic fractures is relatively low compared with other fracture locations. The low incidence is in great contrast to the high morbidity and mortality. Particularly in the elderly, with apparently isolated fractures of the pubic rami, these observations are believed to be due to additional occult lesions of the posterior pelvic ring. In these cases diagnosis cannot be established by conventional imaging alone and SPECT/CT is considered as a diagnostic adjunct. The aim of this study was to assess concomitant bony or soft tissue lesions within the pelvic ring in a population of patients with fractures of the anterior elements. In all patients with no obvious lesions of the posterior pelvic ring on X-rays and CT or with suspicious but inconclusive findings on CT an additional SPECT/CT was carried out in a non-acute setting within 3 days of the trauma. In all cases additional lesions within the pelvic ring were found. Most lesions were vertical sacral fractures, followed by transverse fractures, one non-dislocated fracture of the acetabulum on the side of the pubic rami fracture, and one post-traumatic dilatation of the sacroiliac joint with increased tracer uptake. According to our results after SPECT/CT all patients with pubic rami fracture suffered additional lesions, none detectable previously by X-ray or CT, within the pelvic ring. In this context SPECT/CT has proved to be very helpful in the clinical routine to visualize occult fractures and instability within the sacroiliac joint. (orig.)

  12. Dose dependent disposition of gallium-67 in rats

    International Nuclear Information System (INIS)

    Gautam, S.R.

    1982-01-01

    Radioactive gallium-67 has been employed as a diagnostic and follow-up agent for cancer therapy. Currently gallium nitrate is undergoing Phase I clinical studies. A million fold increase in the concentration of the carrier gallium citrate over the range of carrier-free gallium-67 (pgm) to 1.0 μg caused no significant alteration in the disposition of gallium-67 in rats.Gallium-67 was eliminated from blood with a biological t1/2 of 4.1 days. A linear tissue binding profile was observed for gallium-67 over this concentration range. A multi-compartment pharmacokinetic model was developed in which all the tissues studied were treated as separate compartments. At 1.0 mg dose level, significant alteration in the disposition of gallium-67 was observed in rats, > 95% of the initial radioactivity was characteristic reappearance of the radioactivity in the blood approximately 4 hours after dosing leading to a ''hump'' in the blood concentration-time profiles. Following the 1.0 mg dose low tissue levels were observed, except for the kidneys, which contained about 8% of the administered dose per gram of the tissue one-half hour after dosing. A non-linear tissue binding profile was observed to be associated with gallium at high doses. It was hypothesized that the rapid loss of gallium-67 from the vascular system following the high doses of gallium citrate was due to the accumulation of the drug in the kidneys where it was eventually eliminated via urine. The kidneys thus would act as a temporary storage site for gallium. It was concluded that the dose-related renal toxicity associated with gallium therapy may be attributed to the kidney's role as a temporary storage site following high doses

  13. 99mTc-HMPAO Regional Cerebral Blood Flow SPECT in Transient Ischemic Attacks

    International Nuclear Information System (INIS)

    Ahn, Myeong Im; Park, Young Ha; Lee, Sung Yong; Chung, Soo Kyo; Kim, Jong Woo; Bahk, Yong Whee

    1989-01-01

    Transient ischemic attacks (TJAs) is a syndrome resulting from brain ischemia lasting less than 24 hours. The mechanisms of TIAs may be similar to those of cerebral embolism and thrombosis, and thus TIAs may be followed by cerebral infarction. Despite the availability of CT scanning, the diagnosis and management of TIAs continue to be difficult. Recently SPECT has been advocated as a diagnostic imaging modality. We performed 99m Tc-HMPAO regional cerebral blood flow (rCRF) SPECT in 24 patients with the clinical diagnosis of TIAs to assess its ability to detect early changes of rCBF, and determine the diagnostic value. Ten men and fourteen women with an average of 51 years (range; 27-74 years) were included. All but 8 patients had normal brain CT prior to SPECT. The two patients had moderate degree of brain atrophy and the 6 patients nonspecific calcifications. Eighteen of the 24 patients had abnormal 99m Tc-HMPAO rCBF SPECT. Fifteen had unilateral involvement and the other three had bilateral involvements. Seventy-five percents of the defects were found in the left cerebral hemisphere. According to the distribution of the lesions (total number: 34 lesions), fourteen were in the parietal, eight in the temporal, and the remainders were elsewhere. 99m Tc-HMPAO rCHF SPECT is sensitive in detecting rCRF abnormalities in patients with TIAs, and represent the most accurate diagnostic tool available in the diagnosis of TIAs

  14. The validation and the limits of SPECT for patients suffering from cerebrovascular accidents

    International Nuclear Information System (INIS)

    Mizukawa, Norihiko; Yano, Ichiro; Tenjin, Hiroshi

    1989-01-01

    Contemporaneous single photon emission computed tomography (SPECT) and positron emission tomography (PET) were performed in 10 patients with cerebrovascular accidents (CVA), whose ages ranged from 11 to 67 years. I-123-isopropyl-iodoamphetamine (IMP) and/or Tc-99m hexamethylpropyleneamine oxime (HM-PAO) were used for SPECT. Cerebral blood flow (CBF), oxygen extraction fraction (OEF), and cerebral metabolic rate for oxygen (CMRO 2 ) were measured by an O-15 labelled gas continuous-inhalation method. SPECT images were quite similar to CBF and CMRO 2 during the chronic stage of CVA. Two patietns with vasospasm during the subacute stage had apparently low CBF and CMRO 2 on PET, but did not have low perfusion on SPECT. Luxury perfusion areas were detected in 4 subacute stage patients and one chronic stage patient. A redistribution of IMP was detected in two patients with infarction during subacute stage. CMRO 2 value in such an area was 2.0 ml/100 g/min. Low CBF and/or CMRO 2 areas were well visualized by IMP rather than by HM-PAO SPECT. (N.K.)

  15. Comparative study of FDG-PET and sestamibi-SPECT in the diagnosis of secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Higuchi, T.; Ozawa, K.; Oriuchi, N.; Khan, N.; Endo, K.; Otake, H.; Matsubara, K.

    2002-01-01

    Aim: FDG-PET is reported to be more accurate in preoperative localization of hyper functioning parathyroid gland of primary hyperparathyroidism in comparison with sestamibi-SPECT by Neumann et al. However, its usefulness in the diagnosis of secondary hyperparathyroidism has not been reported yet. In this study, we've performed the direct comparison of the usefulness of FDG-PET and sestamibi-SPECT in the detection of abnormal parathyroid tissue in the patients of secondary hyperparathyroidism under hemodilysis. Material and Methods: One primary and 5 secondary hyperparathyroidism patients underwent FDG-PET and sestamibi-SPECT. After overnight fasting, 300 to 400 MBq of FDG was intravenously injected, followed by whole body PET image acquisition after 50 minutes. In the same day before FDG-PET, 600 MBq of sestamibi was injected and early and delayed planar image and delayed SPECT image has been obtained. Visual interpretation of the abnormal parathyroid uptake has been performed by 2 experienced nuclear physician independently. Results: In the secondary cases, FDG-PET shows no hyper functioning gland in all 5 cases, whereas sestamibi-SPECT shows 8 hyper functioning glands. In contrast, hyper functioning gland of the primary hyperparathyroidism case has been clearly visualized only by FDG-PET. Conclusion: Although FDG-PET is very useful in detecting hyper functioning gland in primary hyperparathyroidism, it is not useful in secondary hyperparathyroidism. Further pathological analysis about the different glucose metabolism of primary and secondary hyper functioning gland should be added in the future study

  16. Precise fusion of MRI and dual energy 111In WBC/99mTc HDP SPECT/CT in the diabetic foot using companion CT: an example of SPECT/MRI imaging

    International Nuclear Information System (INIS)

    Knešaurek, K.; Heiba, S.; Kolker, D.; Vatti, S.

    2015-01-01

    The purpose of our study was to correctly fuse MRI and SPECT 111 In WBC and 99m Tc HDP images using companion CT images. The fused images could be used to assess proper surgical approach in treatment of the diabetic foot. Nine patients who had dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT and MRI studies within a week were investigated in an ongoing project. A GE Infinia SPECT/CT camera and Siemens MAGNETOM 1.5T MR system were used in this study. First, the MRI and corresponding CT images were coregistrated using a transformation based on normalized mutual information. The transformation was saved and used for MRI and 111 In WBC/ 99 m Tc HDP SPECT fusion. A Jaszczak phantom study was also performed in order to estimate accuracy of MRI/ SPECT fusion. The Jaszczak phantom study with 3.7 MBq 111 In hot sphere showed that MRI/SPECT alignment using the approach described above produced registration with 0.7±0.4 mm accuracy in all three dimensions (3D). The nine clinical cases were visually evaluated and showed 1-2 mm 3D fusion accuracy. MRI provides almost perfect anatomy of soft tissue and bony structures but it may exaggerate the extent of infection. 111 In WBC/ 99 m Tc HDP SPECT imaging is more accurate for infection detection but lacks anatomical reference. Combination of these images proved an essential adjunct to diagnosis. A clinical utility of the approach is illustrated in two clinical examples. In conclusion, the CT in dual energy 111 In WBC/ 99 m Tc HDP SPECT/CT studies can be used to accurately fuse and compare 111 In WBC/ 99 m Tc HDP SPECT and MRI images of the diabetic foot. This can significantly help in conservative treatment planning and limb salvage procedures in treatment of diabetic foot infections.

  17. Contralateral thalamic hypoperfusion on brain perfusion SPECT

    International Nuclear Information System (INIS)

    Lee, Seok Mo; Bae, Sang Kyun; Yoo, Kyung Moo; Yum, Ha Yong

    2000-01-01

    Brain perfusion single photon emission computed tomography (SPECT) is useful for the localization of cerebrovascular lesion and sometimes reveals more definite lesion than radiologic imaging modality such as CT or MRI does. The purpose of this study was to evaluate the diagnostic usefulness of brain perfusion SPECT in patients with hemisensory impairment. Thirteen consecutive patients (M:F= 8:5, mean age = 48) who has hemisensory impairment were included. Brain perfusion SPECT was performed after intravenous injection of 1110 MBq of Tc-99m ECD. The images were obtained using a dual-head gamma camera with ultra-high resolution collimator. Semiquantitative analysis was performed after placing multiple ROIs on cerebral cortex, basal ganglia, thalamus and cerebellum. There were 10 patients with left hemisensory impairment and 3 patients with right-sided symptom. Only 2 patients revealed abnormal signal change in the thalamus on MRI. But brain perfusion SPECT showed decreased perfusion in the thalamus in 9 patients. Six patients among 10 patients with left hemisensory impairment revealed decreased perfusion in the contralateral thalamus on brain SPECT. The other 4 patients revealed no abnormality. Two patients among 3 patients with right hemisensory impairment also showed decreased perfusion in the contralateral thalamus on brain SPECT. One patients with right hemisensory impairment showed ipsilateral perfusion decrease. Two patients who had follow-up brain perfusion SEPCT after treatment revealed normalization of perfusion in the thalamus. Brain perfusion SPECT might be a useful tool in diagnosing patients with hemisensory impairment

  18. SPECT of the brain: Present and future

    International Nuclear Information System (INIS)

    Fazio, F.; Lenzi, G.L.

    1986-01-01

    In both PET and SPECT, most of the studies and the models have been addressed to two organs: brain and heart. So far, brain has certainly been investigated more. The several comparisons between planar scintigraphy and SPECT, between X-ray TCT and SPECT, and also between PET and SPECT, have tended to consider SPECT a cheap but scarcely useful tool for a nuclear medicine section. Again the authors feel that this is due to the fact that SPECT is really a ''physiological tomography'', with little known about its physiology or how it is measured. Thus the present state of the art of SPECT of the brain is characterized by a collection of data and reports on brain imaging and by a slowly growing basic understanding of the utilized modes. The introduction of a new brain-imaging radiopharmaceutical is immediately signaled by its ''first clinical application'' without parallel studies on the kinetics, the metabolic degradation, and the real suitability of the molecule as a tracer for measurement of regional CBF. Only a few attempts seek to narrow this discussion between clinic and biology, and the authors like to emphasize the need for nuclear medicine people to dedicate more time and effort

  19. The role of Tc-99m HMPAO brain perfusion SPECT in the psychiatric disability evaluation of patients with chronic traumatic brain injury

    Energy Technology Data Exchange (ETDEWEB)

    So, Young [Nuclear Medicne, Seoul National Univ., Seoul (Korea, Republic of); Lee, Kang Wook; Lee, Sun Woo; Ghi, Lek Sung; Song, Chang June [College of Medicine, Chungnam National Univ., Taejon (Korea, Republic of)

    2002-08-01

    We studied whether brain perfusion SPECT is useful in the psychiatric disability evaluation of patients with chronic traumatic brain injury (TBI). Sixty-nine patients (M:F=58:11, age 39 {+-} 14 years) who underwent Tc-99m HMPAO brain SPECT, brain MRI and neuropsychological (NP) tests during hospitalization in psychiatric wards for the psychiatric disability evaluation were included; the severity of injury was mild in 31, moderate in 17 and severe in 21. SPECT, MRI, NP tests were performed 6 {approx} 61 months (mean 23 months) post-injury. Diagnostic accuracy of SPECT and MRI to show hypoperfusion or abnormal signal intensity in patients with cognitive impairment represented by NP test results were compared. Forty-two patients were considered to have cognitive impairment on NP tests and 27 not. Brain SPECT showed 71% sensitivity and 85% specificity, while brain MRI showed 62% sensitivity and 93% specificity (p>0.05, McNemar test). SPECT found more cortical lesions and MRI was superior in detecting white matter lesions. sensitivity and specificity of 31 mild TBI patients were 45%, 90% for SPECT and 27%, 100% for MRI (p>0.05, McNemar test). Among 41 patients with normal brain MRI, SEPCT showed 63% sensitivity (50% for mild TBI) and 88% specificity (85% for malingerers). Brain SPECT has a supplementary role to neuropsychological tests in the psychiatric disability evaluation of chronic TBI patients by detecting more cortical lesions than MRI.

  20. The role of Tc-99m HMPAO brain perfusion SPECT in the psychiatric disability evaluation of patients with chronic traumatic brain injury

    International Nuclear Information System (INIS)

    So, Young; Lee, Kang Wook; Lee, Sun Woo; Ghi, Lek Sung; Song, Chang June

    2002-01-01

    We studied whether brain perfusion SPECT is useful in the psychiatric disability evaluation of patients with chronic traumatic brain injury (TBI). Sixty-nine patients (M:F=58:11, age 39 ± 14 years) who underwent Tc-99m HMPAO brain SPECT, brain MRI and neuropsychological (NP) tests during hospitalization in psychiatric wards for the psychiatric disability evaluation were included; the severity of injury was mild in 31, moderate in 17 and severe in 21. SPECT, MRI, NP tests were performed 6 ∼ 61 months (mean 23 months) post-injury. Diagnostic accuracy of SPECT and MRI to show hypoperfusion or abnormal signal intensity in patients with cognitive impairment represented by NP test results were compared. Forty-two patients were considered to have cognitive impairment on NP tests and 27 not. Brain SPECT showed 71% sensitivity and 85% specificity, while brain MRI showed 62% sensitivity and 93% specificity (p>0.05, McNemar test). SPECT found more cortical lesions and MRI was superior in detecting white matter lesions. sensitivity and specificity of 31 mild TBI patients were 45%, 90% for SPECT and 27%, 100% for MRI (p>0.05, McNemar test). Among 41 patients with normal brain MRI, SEPCT showed 63% sensitivity (50% for mild TBI) and 88% specificity (85% for malingerers). Brain SPECT has a supplementary role to neuropsychological tests in the psychiatric disability evaluation of chronic TBI patients by detecting more cortical lesions than MRI

  1. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  2. High resolution SPECT imaging for visualization of intratumoral heterogeneity using a SPECT/CT scanner dedicated for small animal imaging

    International Nuclear Information System (INIS)

    Umeda, Izumi O.; Tani, Kotaro; Tsuda, Keisuke

    2012-01-01

    Tumor interiors are never homogeneous and in vivo visualization of intratumoral heterogeneity would be an innovation that contributes to improved cancer therapy. But, conventional nuclear medicine tests have failed to visualize heterogeneity in vivo because of limited spatial resolution. Recently developed single photon emission computed tomographic (SPECT) scanners dedicated for small animal imaging are of interest due to their excellent spatial resolution of 111 In and simulations of actual small animal imaging. The optimal conditions obtained were validated by in vivo imaging of sarcoma 180-bearing mice. Larger number of counts must be obtained within limited acquisition time to visualize tumor heterogeneity in vivo in animal imaging, compared to cases that simply detect tumors. At an acquisition time of 30 min, better image quality was obtained with pinhole apertures diameter of 1.4 mm than of 1.0 mm. The obtained best spatial resolution was 1.3 mm, it was acceptable for our purpose, though a little worse than the best possible performance of the scanner (1.0 mm). Additionally, the reconstruction parameters, such as noise suppression, voxel size, and iteration/subset number, needed to be optimized under the limited conditions and were different from those found under the ideal condition. The minimal radioactivity concentration for visualization of heterogeneous tumor interiors was estimated to be as high as 0.2-0.5 MBq/mL. Liposomes containing 111 In met this requirement and were administered to tumor-bearing mice. SPECT imaging successfully showed heterogeneous 111 In distribution within the tumors in vivo with good spatial resolution. A threshold of 0.2 MBq/g for clear visualization of tumor heterogeneity was validated. Autoradiograms obtained ex vivo of excised tumors confirmed that the in vivo SPECT images accurately depicted the heterogeneous intratumoral accumulation of liposomes. Intratumoral heterogeneity was successfully visualized under the optimized

  3. Memory-provoked rCBF-SPECT as a diagnostic tool in Alzheimer's disease?

    Energy Technology Data Exchange (ETDEWEB)

    Sundstroem, Torbjoern; Riklund, Katrine Aa. [Umeaa University, Umeaa University Hospital, Department of Radiation Sciences, Diagnostic Radiology, Umeaa (Sweden); Elgh, Eva; Naesman, Birgitta [Umeaa University, Department of Community Medicine and Rehabilitation, Geriatric Medicine, Umeaa (Sweden); Larsson, Anne [Umeaa University, Department of Radiation Sciences, Radiation Physics, Umeaa (Sweden); Nyberg, Lars [Umeaa University, Department of Psychology, Umeaa (Sweden)

    2006-01-01

    Alzheimer's disease (AD) is a primary degenerative disease that progressively affects all brain functions, with devastating consequences for the patient, the patient's family and society. Rest regional cerebral blood flow (rCBF) could have a strategic role in differentiating between AD patients and normal controls, but its use for this purpose has a low discriminatory capacity. The purpose of this study was to evaluate whether the diagnostic sensitivity of rCBF single-photon emission computed tomography (SPECT) could be increased by using an episodic memory task provocation, i.e. memory-provoked rCBF-SPECT (MP-SPECT). Eighteen persons (73.2{+-}4.8 years) with mild AD and 18 healthy elderly (69.4{+-}3.9 years) were included in the study. The subjects were injected with{sup 99m}Tc-hexamethylpropylene amine oxime (HMPAO) during memory provocation with faces and names, followed by an rCBF-SPECT study. The rCBF{sup 99m}Tc-HMPAO SPECT images were analysed using statistical parametric mapping (SPM2). Peaks with a false discovery rate corrected value of 0.05 were considered significant. On MP-SPECT, the AD group showed a significant rCBF reduction in the left parietal cortex in comparison with healthy elderly. At rest, no significant group differences were seen. Memory provocation increased the sensitivity of rCBF-SPECT for the detection of AD-related blood flow changes in the brain at the group level. Further studies are needed to evaluate MP-SPECT as a diagnostic tool at the individual level. If a higher sensitivity for AD at the individual level is verified in future studies, a single MP-SPECT study might be sufficient in the clinical setting. (orig.)

  4. Analysis of brain SPECT with the statistical parametric mapping package SPM99

    International Nuclear Information System (INIS)

    Barnden, L.R.; Rowe, C.C.

    2000-01-01

    Full text: The Statistical Parametric Mapping (SPM) package of the Welcome Department of Cognitive Neurology permits detection in the brain of different regional uptake in an individual subject or a population of subjects compared to a normal population. SPM does not require a-priori specification of regions of interest. Recently SPM has been upgraded from SPM96 to SPM99. Our aim was to vary brain SPECT processing options in the application of SPM to optimise the final statistical map in three clinical trials. The sensitivity of SPM depends on the fidelity of the preliminary spatial normalisation of each scan to the standard anatomical space defined by a template scan provided with SPM. We generated our own SPECT template and compared spatial normalisation to it and to SPM's internal PET template. We also investigated the effects of scatter subtraction, stripping of scalp activity, reconstruction algorithm, non-linear deformation and derivation of spatial normalisation parameters using co-registered MR. Use of our SPECT template yielded better results than with SPM's PET template. Accuracy of SPECT to MR co-registration was 2.5mm with SPM96 and 1.2mm with SPM99. Stripping of scalp activity improved results with SPM96 but was unnecessary with SPM99. Scatter subtraction increased the sensitivity of SPM. Non-linear deformation additional to linear (affine) transformation only marginally improved the final result. Use of the SPECT template yielded more significant results than those obtained when co registered MR was used to derive the transformation parameters. SPM99 is more robust than SPM96 and optimum SPECT analysis requires a SPECT template. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. Determination of gallium in flint clay by neutron activation analysis

    International Nuclear Information System (INIS)

    Padova, A.; Even, O.

    1975-01-01

    Neutron activation analysis was applied to determine gallium traces in different flint clay samples found in Israel. The principal 835 KeV gamma ray of gallium-72 was measured with a 60 cm 2 Ge(Li) spectrometer in conjunction with a Packard 4000 channel analyzer and Wang table computer, model 720 C. Samples were weighed into polyethylene vials, sealed and inserted into polyethylene rabbit. Gallium metal and gallium oxide used as standards were similarly prepared for irradiation for 10 minutes in the I.R.R.I., at a thermal flux of 3.5x10 12 n/cm 2 sec. Careful calibration of the spectrometer and judicious choice of cooling time eliminate the influence of such elements as europium-152, and sodium-24 and make possible the determination of gallium without prior chemical separation. Representative Israel flint clay samples contain about 55 ppm gallium. (B.G.)

  6. Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism.

    Science.gov (United States)

    Sommerauer, Michael; Graf, Carmen; Schäfer, Niklaus; Huber, Gerhard; Schneider, Paul; Wüthrich, Rudolf; Schmid, Christoph; Steinert, Hans

    2015-01-01

    Despite recommendations for 99mTc-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope 99mTc-tetrofosmin and 123I sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes. Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed. In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89 ± 46 vs. 129 ± 41 minutes, p = 0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions. Dual-isotope SPECT with 99mTc-tetrofosmin and 123I sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.

  7. Facial osteomyelitis as complication of chronic sinusitis in hemophiliac-AIDS patients - scintigraphic evaluation with technetium-99m-MDP and Gallium-67

    International Nuclear Information System (INIS)

    Marques, Marise da Penha Costa; Wolosker, Sara; Marchiori, Edson

    1997-01-01

    In the paper six cases of facial osteomyelitis as a complication of chronic sinusitis in hemophiliac-AIDS patients are reported. Osteomyelitis was suggested by an increasing of erythrocyte sedimentation rate. The diagnosis was confirmed by a positive 99m Tc MDP scintigraphy. The patients were submitted to clinical treatment. The erythrocyte sedimentation rate and 67-gallium citrate scans were used in the follow-up of the therapy. Three patients had negative gallium after three weeks of organism-specific antibiotic therapy; in two patients the gallium scintigraphy remained positive. One patient did not undergo the radionuclide scan for this clinical conditions. These results suggest that MDP scans showed higher sensitivity and specificity in detection of bone disease in chronic sinusitis. Gallium scans appeared to be valuable tool in the follow-up of the infection. There are no reports in the literature of osteomyelitis as a complication of chronic sinusitis in AIDS patient. (author)

  8. Diagnostic pathway of integrated SPECT/CT for coronary artery disease

    International Nuclear Information System (INIS)

    Slart, Riemer H.J.A.; Tio, Rene A.; Zijlstra, Felix; Dierckx, Rudi A.

    2009-01-01

    Treatment strategy in patients with suspected coronary artery disease (CAD) is driven by symptomatology in combination with diagnostic evaluation of the extent and/or severity of atherosclerosis in the coronary arteries and ischemia in the myocardium, i.e., the anatomic and functional correlates of CAD. Whereas multislice row computed tomography (MSCT) has the advantage of detecting coronary atherosclerosis at its earliest stages, thereby allowing initiation of appropriate therapeutic measures well before development of obstructive CAD, myocardial perfusion imaging (MPI) SPECT can clarify the hemodynamic consequences of the anatomic findings on MSCT based on a functional assessment of myocardial blood flow. There is a lack of correlation between coronary artery calcium (CAC), coronary artery stenosis, and MPI SPECT. Therefore CAC scoring and stress MPI should be thus considered complementary approaches rather than exclusionary in the evaluation of the patient at risk for CAD. The integration of anatomic and functional information may provide additional information for the clinician by the improved risk stratification and diagnostic accuracy of integrated techniques. The majority of previous studies are based on a sequential flowchart, starting with either SPECT or CAC scoring that finally directs the therapeutic strategy. Patients at low risk for CAD can be selected for primary prevention, and patients at high risk for CAD can be directly selected for coronary angiography (CAG). The remaining group of patients at intermediate risk for CAD can be substratified into lower- and higher-risk categories based on the presence or absence of stress-induced ischemia on MPI SPECT and CAC scoring. An integration of SPECT and CAC as a starting point for CAD detection in symptomatic patients at intermediate risk for CAD may facilitate a tailored diagnostic as well as therapeutic approach. Finally, using SPECT/CT, MPI SPECT, and CAC findings may be completed with CT angiography

  9. Interactions of Zircaloy cladding with gallium: 1998 midyear status

    International Nuclear Information System (INIS)

    Wilson, D.F.; DiStefano, J.R.; Strizak, J.P.; King, J.F.; Manneschmidt, E.T.

    1998-06-01

    A program has been implemented to evaluate the effect of gallium in mixed-oxide (MOX) fuel derived from weapons-grade (WG) plutonium on Zircaloy cladding performance. The objective is to demonstrate that low levels of gallium will not compromise the performance of the MOX fuel system in a light-water reactor. The graded, four-phase experimental program was designed to evaluate the performance of prototypic Zircaloy cladding materials against (1) liquid gallium (Phase 1), (2) various concentrations of Ga 2 O 3 (Phase 2), (3) centrally heated surrogate fuel pellets with expected levels of gallium (Phase 3), and (4) centrally heated prototypic MOX fuel pellets (Phase 4). This status report describes the results of a series of tests for Phases 1 and 2. Three types of tests are being performed: (1) corrosion, (2) liquid metal embrittlement, and (3) corrosion-mechanical. These tests will determine corrosion mechanisms, thresholds for temperature and concentration of gallium that may delineate behavioral regimes, and changes in the mechanical properties of Zircaloy. Initial results have generally been favorable for the use of WG-MOX fuel. The MOX fuel cladding, Zircaloy, does react with gallium to form intermetallic compounds at ≥300 C; however, this reaction is limited by the mass of gallium and is therefore not expected to be significant with a low level (parts per million) of gallium in the MOX fuel. Although continued migration of gallium into the initially formed intermetallic compound can result in large stresses that may lead to distortion, this was shown to be extremely unlikely because of the low mass of gallium or gallium oxide present and expected clad temperatures below 400 C. Furthermore, no evidence for grain boundary penetration by gallium has been observed

  10. Survey of the market, supply and availability of gallium

    Energy Technology Data Exchange (ETDEWEB)

    Rosi, F.D.

    1980-07-01

    The objective of this study was to assess the present consumption and supply of gallium, its potential availability in the satellite power system (SPS) implementation time frame, and commercial and new processing methods for increasing the production of gallium. Findings are reported in detail. The findings strongly suggest that with proper long range planning adequate gallium would be available from free-enterprise world supplies of bauxite for SPS implementation.

  11. Interactions of zircaloy cladding with gallium -- 1997 status

    International Nuclear Information System (INIS)

    Wilson, D.F.; DiStefano, J.R.; King, J.F.; Manneschmidt, E.T.; Strizak, J.P.

    1997-11-01

    A four phase program has been implemented to evaluate the effect of gallium in mixed oxide (MOX) fuel derived from weapons grade (WG) plutonium on Zircaloy cladding performance. The objective is to demonstrate that low levels of gallium will not compromise the performance of the MOX fuel system in LWR. This graded, four phase experimental program will evaluate the performance of prototypic Zircaloy cladding materials against: (1) liquid gallium (Phase 1), (2) various concentrations of Ga 2 O 3 (Phase 2), (3) centrally heated surrogate fuel pellets with expected levels of gallium (Phase 3), and (4) centrally heated prototypic MOX fuel pellets (Phase 4). This status report describes the results of an initial series of tests for phases 1 and 2. Three types of tests are being performed: (1) corrosion, (2) liquid metal embrittlement (LME), and (3) corrosion mechanical. These tests are designed to determine the corrosion mechanisms, thresholds for temperature and concentration of gallium that may delineate behavioral regimes, and changes in mechanical properties of Zircaloy. Initial results have generally been favorable for the use of WG-MOX fuel. The MOX fuel cladding, Zircaloy, does react with gallium to form intermetallic compounds at ≥ 300 C; however, this reaction is limited by the mass of gallium and is therefore not expected to be significant with a low level (in parts per million) of gallium in the MOX fuel. While continued migration of gallium into the initially formed intermetallic compound results in large stresses that can lead to distortion, this is also highly unlikely because of the low mass of gallium or gallium oxide present and expected clad temperatures below 400 C. Furthermore, no evidence for grain boundary penetration by gallium has been observed

  12. Inflammatory pseudotumor: A gallium-avid mobile mesenteric mass

    International Nuclear Information System (INIS)

    Auringer, S.T.; Scott, M.D.; Sumner, T.E.

    1991-01-01

    An 8-yr-old boy with a 1-mo history of culture-negative fever and anemia underwent gallium, ultrasound, and computed tomography studies as part of the evaluation of a fever of unknown origin. These studies revealed a mobile gallium-avid solid abdominal mass subsequently proven to be an inflammatory pseudotumor of the mesentery, a rare benign mass. This report documents the gallium-avid nature of this rare lesion and discusses associated characteristic clinical, pathologic, and radiographic features

  13. Relationship between coronary contrast-flow quantitative flow ratio and myocardial ischemia assessed by SPECT MPI

    Energy Technology Data Exchange (ETDEWEB)

    Smit, Jeff M.; Rosendael, Alexander R. van; Jukema, J.W.; Delgado, Victoria; Bax, Jeroen J.; Scholte, Arthur J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Koning, Gerhard [Medis Medical Imaging Systems B.V., Leiden (Netherlands); Dibbets-Schneider, Petra [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands); Mertens, Bart J. [Leiden University Medical Center, Department of Medical Statistics, Leiden (Netherlands); Reiber, Johan H.C. [Medis Medical Imaging Systems B.V., Leiden (Netherlands); Leiden University Medical Center, Department of Radiology, Leiden (Netherlands)

    2017-10-15

    A new method has been developed to calculate fractional flow reserve (FFR) from invasive coronary angiography, the so-called ''contrast-flow quantitative flow ratio (cQFR)''. Recently, cQFR was compared to invasive FFR in intermediate coronary lesions showing an overall diagnostic accuracy of 85%. The purpose of this study was to investigate the relationship between cQFR and myocardial ischemia assessed by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). Patients who underwent SPECT MPI and coronary angiography within 3 months were included. The cQFR computation was performed offline, using dedicated software. The cQFR computation was based on 3-dimensional quantitative coronary angiography (QCA) and computational fluid dynamics. The standard 17-segment model was used to determine the vascular territories. Myocardial ischemia was defined as a summed difference score ≥2 in a vascular territory. A cQFR of ≤0.80 was considered abnormal. Two hundred and twenty-four coronary arteries were analysed in 85 patients. Overall accuracy of cQFR to detect ischemia on SPECT MPI was 90%. In multivariable analysis, cQFR was independently associated with ischemia on SPECT MPI (OR per 0.01 decrease of cQFR: 1.10; 95% CI 1.04-1.18, p = 0.002), whereas clinical and QCA parameters were not. Furthermore, cQFR showed incremental value for the detection of ischemia compared to clinical and QCA parameters (global chi square 48.7 to 62.6; p <0.001). A good relationship between cQFR and SPECT MPI was found. cQFR was independently associated with ischemia on SPECT MPI and showed incremental value to detect ischemia compared to clinical and QCA parameters. (orig.)

  14. Relationship Between Coronary Contrast-Flow Quantitative Flow Ratio and Myocardial Ischemia Assessed by SPECT MPI.

    Science.gov (United States)

    Smit, Jeff M; Koning, Gerhard; van Rosendael, Alexander R; Dibbets-Schneider, Petra; Mertens, Bart J; Jukema, J Wouter; Delgado, Victoria; Reiber, Johan H C; Bax, Jeroen J; Scholte, Arthur J

    2017-10-01

    A new method has been developed to calculate fractional flow reserve (FFR) from invasive coronary angiography, the so-called "contrast-flow quantitative flow ratio (cQFR)". Recently, cQFR was compared to invasive FFR in intermediate coronary lesions showing an overall diagnostic accuracy of 85%. The purpose of this study was to investigate the relationship between cQFR and myocardial ischemia assessed by single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI). Patients who underwent SPECT MPI and coronary angiography within 3 months were included. The cQFR computation was performed offline, using dedicated software. The cQFR computation was based on 3-dimensional quantitative coronary angiography (QCA) and computational fluid dynamics. The standard 17-segment model was used to determine the vascular territories. Myocardial ischemia was defined as a summed difference score ≥2 in a vascular territory. A cQFR of ≤0.80 was considered abnormal. Two hundred and twenty-four coronary arteries were analysed in 85 patients. Overall accuracy of cQFR to detect ischemia on SPECT MPI was 90%. In multivariable analysis, cQFR was independently associated with ischemia on SPECT MPI (OR per 0.01 decrease of cQFR: 1.10; 95% CI 1.04-1.18, p = 0.002), whereas clinical and QCA parameters were not. Furthermore, cQFR showed incremental value for the detection of ischemia compared to clinical and QCA parameters (global chi square 48.7 to 62.6; p relationship between cQFR and SPECT MPI was found. cQFR was independently associated with ischemia on SPECT MPI and showed incremental value to detect ischemia compared to clinical and QCA parameters.

  15. Diagnosis of silent myocardial ischemia in type 2 diabetic patients by electrocardiogram, ergometry and Gated-SPECT

    International Nuclear Information System (INIS)

    Penna Quian, Yamile; Fernandez-Britto Rodriguez, Jose; Bacallao Gallestey, Jorge; Batista Cuellar, Juan Felipe; Coca Perez, Marco Antonio; Toirac Garcia, Noresma; Penna Coego, Andria

    2008-01-01

    31 asymptomatic type 2 diabetic patients were studied by lab tests, electrocardiogram, ergometry, Gated-SPECT and coronariography to determine the relation between the atherosclerotic risk factors and the silent myocardial ischemia. Patients were classified into two groups: positive SPECT and negative SPECT. Association tests were made for each variable and ROC curves were constructed to identify risk markers. In 35.5% of the patients silent myocardial ischemia was detected with a good angiographic correlation. A significant association was evidenced between positive SPECT and the atherosclerotic risk factors, namely, low values of HDLc, family pathological history of ischemic heart disease and peripheral vascular disease. The logistic regression models showed that low values of HDLc together with family pathological history of ischemic heart disease may be strong predictors of silent myocardial ischemia in asymptomatic type 2 diabetic patients

  16. Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Caobelli, Federico; Thackeray, James T.; Bengel, Frank M. [Medizinische Hochschule Hannover, Klinik fuer Nuklearmedizin, Hannover (Germany); Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo [Fondazione Poliambulanza, Department of Nuclear Medicine, Brescia (Italy)

    2015-11-15

    IQ-SPECT, an add-on to general purpose cameras based on multifocal collimation, can reduce myocardial perfusion imaging (MPI) acquisition times to one-fourth that of standard procedures (to 12 s/view). In a phantom study, a reduction of the acquisition time to one-eighth of the standard time (to 6 s/view) was demonstrated as feasible. It remains unclear whether such a reduction could be extended to clinical practice. Fifty patients with suspected or diagnosed CAD underwent a 2-day stress-rest {sup 99m}Tc-sestamibi MPI protocol. Two consecutive SPECT acquisitions (6 and 12 s/view) were performed. Electrocardiogram-gated images were reconstructed with and without attenuation correction (AC). Polar maps were generated and visually scored by two blinded observers for image quality and perfusion in 17 segments. Global and regional summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS) were determined. Left ventricular volumes and ejection fraction were calculated based on automated contour detection. Image quality was scored higher with the 12 s/view acquisition, both with and without AC. Summed scores were statistically comparable between the 6 s/view and the 12 s/view acquisition, both globally and in individual coronary territories (e.g. in images with AC, SSS were 6.6 ± 8.3 and 6.2 ± 8.2 with 6 s and 12 s/view, respectively, p = 0.10; SRS were 3.9 ± 5.6 and 3.5 ± 5.3, respectively, p = 0.19; and SDS were 2.8 ± 5.7 and 2.6 ± 5.7, respectively, p = 0.59). Both acquisitions allowed MPI-based diagnosis of CAD in 25 of the 50 patients (with AC). Calculated end-diastolic volume (EDV) and end-systolic volume (ESV) were modestly higher with the 6 s/view acquisition than with the 12 s/view acquisition (EDV +4.8 ml at rest and +3.7 ml after stress, p = 0.003; ESV +4.1 ml at rest and +2.6 ml after stress, p = 0.01), whereas the ejection fraction did not differ (-1.2 % at rest, p = 0.20, and -0.9 % after stress, p = 0.27). Image quality and

  17. SPECT assay of radiolabeled monoclonal antibodies

    International Nuclear Information System (INIS)

    Jaszczak, R.J.

    1992-02-01

    The long-term goal of this research project is to develop methods to improve the utility of single photon emission computed tomography (SPECI) to quantify the biodistribution of monoclonal antibodies (MoAbs) labeled with clinically relevant radionuclides ( 123 I, 131 I, and 111 In) and with another radionuclide, 211 At, recently used in therapy. We describe here our progress in developing quantitative SPECT methodology for 111 In and 123 I. We have focused our recent research thrusts on the following aspects of SPECT: (1) The development of improved SPECT hardware, such as improved acquisition geometries. (2) The development of better reconstruction methods that provide accurate compensation for the physical factors that affect SPECT quantification. (3) The application of carefully designed simulations and experiments to validate our hardware and software approaches

  18. Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws

    Energy Technology Data Exchange (ETDEWEB)

    Hudyana, Hendrah; Maes, Alex [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Hospital Leuven, Department of Morphology and Medical Imaging, Leuven (Belgium); Vandenberghe, Thierry; Fidlers, Luc [AZ Groeninge, Department of Neurosurgery, Kortrijk (Belgium); Sathekge, Mike [University of Pretoria, Department of Nuclear Medicine, Pretoria (South Africa); Nicolai, Daniel [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2016-02-15

    osteodegeneration in 7 patients and 1 patient, respectively). Overall sensitivity and specificity for the detection of loosening were 100 % and 89.7 %, respectively. The positive and negative predictive values were 69 % and 100 %, respectively. This retrospective analysis suggests that bone SPECT/CT bone is a highly sensitive and specific tool for the exclusion of screw loosening in patients who present with recurrent low back pain after having undergone lumbar arthrodesis. In addition, it can identify other potential causes of recurrent low back pain in this patient population. (orig.)

  19. Gallium Nitride Crystals: Novel Supercapacitor Electrode Materials.

    Science.gov (United States)

    Wang, Shouzhi; Zhang, Lei; Sun, Changlong; Shao, Yongliang; Wu, Yongzhong; Lv, Jiaxin; Hao, Xiaopeng

    2016-05-01

    A type of single-crystal gallium nitride mesoporous membrane is fabricated and its supercapacitor properties are demonstrated for the first time. The supercapacitors exhibit high-rate capability, stable cycling life at high rates, and ultrahigh power density. This study may expand the range of crystals as high-performance electrode materials in the field of energy storage. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Kong, Eun Jung; Cho, Ihn Ho [Yeungnam University Hospital, Daegu (Korea, Republic of); Kang, Won Jun [Yonsei University Hospital, Seoul (Korea, Republic of); Kim, Seong Min [Chungnam National University Medical School and Hospital, Daejeon (Korea, Republic of); Won, Kyoung Sook [Keomyung University Dongsan Hospital, Daegu (Korea, Republic of); Lim, Seok Tae [Chonbuk National University Medical School and Hospital, Jeonju (Korea, Republic of); Hwang, Kyung Hoon [Gachon University Gil Hospital, Incheon (Korea, Republic of); Lee, Byeong Il; Bom, Hee Seung [Chonnam National University Medical School and Hospital, Gwangju (Korea, Republic of)

    2009-12-15

    Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Forty-eight patients (M:F=26:22, Age: 63.3{+-}10.4 years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

  1. Early and delayed Tc-99m ECD brain SPECT in SLE patients with CNS involvement

    International Nuclear Information System (INIS)

    Kikukawa, Kaoru; Toyama, Hiroshi; Katayama, Masao

    2000-01-01

    We compared early and delayed Tc-99m ECD SPECT scans in 32 SLE patients (Group 1, definite neuropsychiatric disorders; Group 2, minor neurologic symptoms or normal) with those of normal controls by visual inspection and semi-quantitative evaluation. With visual interpretation, 13 out of 14 patients in Group 1 (93%) and 7 out of 18 patients in Group 2 (39%) had diffuse uneven decrease in early scans. Seven patients in Group 2 (39%) who had normal early scans demonstrated focal decrease in the medial frontal lobe in delayed scans. With cerebral region to cerebellar ratios, in early scans, the medial frontal lobe in Group 1 and Group 2 was significantly lower than in normal controls, and lateral frontal lobe and occipital lobes in Group 1 were significantly lower than in normal controls. Nevertheless, in delayed scans, every cortical region except for the parietal lode in Groups 1 and 2 was significantly lower than in normal controls. The retention rates in all regions in SLE patients were significantly lower than in normal controls. No case showed SPECT improvement on follow-up studies in either group in spite of clinical improvement. Delayed Tc-99m ECD brain SPECT of high sensitivity might be useful in detecting CNS involvement. Although the SPECT findings did not correlate with the neuropsychiatric symptoms, early and delayed Tc-99m ECD SPECT seems to provide useful objective diagnostic information in SLE patients. (author)

  2. The significance of the bone single photon emission computed tomography (SPECT) for lumbar spondylolysis in adolescence

    Energy Technology Data Exchange (ETDEWEB)

    Habaguchi, Tatsuya; Hashimoto, Tomoyuki; Tada, Hiroshi; Ohkoshi, Yasumitsu; Shigenobu, Keiichi; Takemitsu, Masakazu; Yamane, Shigeru [Hakodate Central General Hospital, Hokkaido (Japan)

    1999-05-01

    The usefulness of the bone SPECT was examined by the comparison with the simple radiographs and the planar and the SPECT images of the bone scintigram obtained from cases which were diagnosed as the lumbar spondylolysis. Subjects were 36 patients (male: 26, female: 10, age: from 7 to 19 years, mean age: 15.6 years). The have had the sports experience and complained of low back pain for more than two months with no lower limb pain. The bone SPECT was more useful in the early detection of the lumbar spondylolysis in adolescence than the planar examination. It was also usefulness in the planning of the treatment including the restriction of exercise and the treatment by the equipments. It seemed to be useful to observe the progress of the treatment in the conservative treatment. But the bone SPECT is expensive, and the problems of the exposure and the equipments remain unsolved. So the bone SPECT should be performed restricting the cases under the consideration of ages, the sports experience and the duration of the lower back pain. (K.H.)

  3. The significance of the bone single photon emission computed tomography (SPECT) for lumbar spondylolysis in adolescence

    International Nuclear Information System (INIS)

    Habaguchi, Tatsuya; Hashimoto, Tomoyuki; Tada, Hiroshi; Ohkoshi, Yasumitsu; Shigenobu, Keiichi; Takemitsu, Masakazu; Yamane, Shigeru

    1999-01-01

    The usefulness of the bone SPECT was examined by the comparison with the simple radiographs and the planar and the SPECT images of the bone scintigram obtained from cases which were diagnosed as the lumbar spondylolysis. Subjects were 36 patients (male: 26, female: 10, age: from 7 to 19 years, mean age: 15.6 years). The have had the sports experience and complained of low back pain for more than two months with no lower limb pain. The bone SPECT was more useful in the early detection of the lumbar spondylolysis in adolescence than the planar examination. It was also usefulness in the planning of the treatment including the restriction of exercise and the treatment by the equipments. It seemed to be useful to observe the progress of the treatment in the conservative treatment. But the bone SPECT is expensive, and the problems of the exposure and the equipments remain unsolved. So the bone SPECT should be performed restricting the cases under the consideration of ages, the sports experience and the duration of the lower back pain. (K.H.)

  4. Brain SPECT in psychiatry: Delusion or reality?

    International Nuclear Information System (INIS)

    Pavel, D.G.; Davis, G.; Epstein, P.; Kohn, R.; Antonino, F.; Devore-Best, S.; Craita, I.; Liu, P.

    2002-01-01

    Aim: The need for functional information is becoming increasingly evident for proper therapeutic approaches to the treatment and follow up of psychiatric diseases. While data on this subject already exists, there is a general lack of consensus about the use of brain SPECT in this domain and also a considerable negative prejudice due to a number of factors including poor quality imaging and unrealistic expectations. Based on a large group of brain SPECT-s performed over the past 3 years we attempted to sort and refine the indications for SPECT in psychiatry. Materials and Methods: High resolution brain SPECT was performed with triple head gamma camera, super-high resolution fan beam collimator and Tc-HMPAO. A comprehensive semiquantitative color, 3D surface as well as multi-thresholded volume display was routinely used and supplemented by automatic realignment in case of longitudinal follow-up. Results: 470 brain SPECT-s done on 432 patients were all referred by psychiatrists or neuro-psychiatrists for a wide spectrum of psychiatric diseases and ranged in age from 7 to 88 years. The most common primary reasons for referral were : attention deficit hyperactive disorder (ADHD); anxiety; obsessive-compulsive disease, depression (refractory, chronic, bipolar ), impulse control problems; oppositional defiance, post traumatic brain injury; seizures, learning difficulties, pervasive development disorders, memory loss and differential of dementia. Among common denominators were long duration of the disease, unresponsiveness to treatment, worsening of clinical status, and presence of multiple conditions at the same time. The multiparametric display used enabled a comprehensive evaluation of the brain volume which included the hemispheric surfaces; the basal ganglia (striatum) and the thalamus, several components of the limbic and paralimbic systems: anterior and posterior cingulate and their respective subdivisions, insula-s and their subdivisions, apical and mesial

  5. Brain SPECT imaging in temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Krausz, Y.; Yaffe, S.; Atlan, H.; Cohen, D.; Konstantini, S.; Meiner, Z.

    1991-01-01

    Temporal lobe epilepsy is diagnosed by clinical symptoms and signs and by localization of an epileptogenic focus. A brain SPECT study of two patients with temporal lobe epilepsy, using 99m Tc-HMPAO, was used to demonstrate a perfusion abnormality in the temporal lobe, while brain CT and MRI were non-contributory. The electroencephalogram, though abnormal, did not localize the diseased area. The potential role of the SPECT study in diagnosis and localization of temporal lobe epilepsy is discussed. (orig.)

  6. Role of brain SPECT in epilepsy exploration

    International Nuclear Information System (INIS)

    Biraben, A.; Bernard, AM.

    1996-01-01

    The management of epileptic patients is currently developing in relation with the introduction of video EEG and the opening of medical centers dedicated to epilepsy. The role of SPECT is now well established to assess the temporal and spatial dynamic phenomena during seizures. Ictal SPECT has technical and organisational requirements but is a very sensitive method, which appears to be superior to other available imaging techniques. (author)

  7. Gallium-cladding compatibility testing plan. Phases 1 and 2: Test plan for gallium corrosion tests. Revision 2

    International Nuclear Information System (INIS)

    Wilson, D.F.; Morris, R.N.

    1998-05-01

    This test plan is a Level-2 document as defined in the Fissile Materials Disposition Program Light-Water-Reactor Mixed-Oxide Fuel Irradiation Test Project Plan. The plan summarizes and updates the projected Phases 1 and 2 Gallium-Cladding compatibility corrosion testing and the following post-test examination. This work will characterize the reactions and changes, if any, in mechanical properties that occur between Zircaloy clad and gallium or gallium oxide in the temperature range 30--700 C

  8. SPECT/CT versus MRI in patients with nonspecific pain of the hand and wrist - a pilot study

    International Nuclear Information System (INIS)

    Huellner, Martin W.; Buerkert, Alexander; Schleich, Florian S.; Strobel, Klaus; Veit-Haibach, Patrick; Schuerch, Maja; Hug, Urs; Wartburg, Urs von

    2012-01-01

    Hand and wrist pain is a diagnostic challenge for hand surgeons and radiologists due to the complex anatomy of the involved small structures. The American College of Radiology recommends MRI as the study of choice in patients with chronic wrist pain if radiographs are negative. Lately, state-of-the-art SPECT/CT systems have been introduced and may help in the diagnosis of this selected indication. This retrospective study included 21 patients with nonspecific pain of the hand/wrist. The diagnosis of nonspecific wrist pain was made by the referring hand surgeon based on patient history, clinical examination, plain radiography and clinical guidelines. All patients received planar early-phase imaging and late-phase SPECT/CT imaging as well as MRI. Lesions were divided into major (causative) and minor (not causative) pathologies according to clinical follow-up. Furthermore, oedema-like bone marrow changes seen on MRI were compared with focally increased tracer uptake seen on SPECT/CT images. MRI yielded a quite high sensitivity (0.86), but a low specificity (0.20). In contrast, SPECT/CT yielded a high specificity (1.00) and a low sensitivity (0.71). Oedema-like bone marrow changes were detected in 15 lesions in 11 patients. In ten lesions with bone marrow oedema on MRI, foci of elevated tracer uptake were detected on SPECT/CT. Overall, MRI was more sensitive, but SPECT/CT was more specific in the evaluation of causative pathologies. In this initial comparison, SPECT/CT showed higher specificity than MRI in the evaluation of causative pathologies in patients with nonspecific wrist pain. However, MRI was more sensitive. Thus, SPECT/CT was shown to be a useful problem-solving tool in the diagnostic work-up of these patients. (orig.)

  9. Diagnostic value of myocardial perfusion SPECT in the prediction of restenosis after coronary artery bypass graft surgery

    International Nuclear Information System (INIS)

    Paeng, J. C.; Lee, D. S.; Kang, W. J.; Kim, K. B.; Chung, J. K.; Lee, M. C.

    2002-01-01

    Myocardial SPECT has been reported to be sensitive in the detection of restenosis after revascularization. However, the diagnostic value is not well established in bypass graft surgery (CABG), due to significant influences of characteristics of graft vessels and the time interval between CABG and the SPECT. In this study, we evaluated the diagnostic value of myocardial SPECT for the restenosis after CABG. A total of 160 patients with coronary artery disease (M:F=118:42, 60±8 yr) who had undergone CABG were included. Rest T1-201/ dipyridamole stress Tc-99m-MIBI SPECT was performed 3 months (103±16 days) after CABG. Segmental perfusion was quantified using a 20-segment model, and segments of reversible perfusion defect (REV) were defined. Follow-up coronary angiography was performed 1 year (397±104 days) after CABG. The segments of REV were compared between arterial and venous graft groups. And the diagnostic power of 3-month SPECT was evaluated for the prediction of restenosis. On the 3-month SPECT, 620 segments showed REV. The segments of REV were 37% of artery-grafted segments and 36% of vein-grafted segments (p=n.s.). On 1-year coronary angiography, 113 graft vessels (28%) showed restenosis. The overall sensitivity and specificity of REV on 3-month SPECT for the prediction of restenosis were 46% and 67%, respectively, but 52% and 68%, in artery-graft group. REV detected on 3-month SPECT has a predictive value, especially, high specificity for the prediction of restenosis after CABG, which was more definite in artery-graft group

  10. Usefulness of MRI and SPECT studies in evaluating the lesion of aphasia

    Energy Technology Data Exchange (ETDEWEB)

    Hanyu, Haruo; Kobayashi, Yasutaka; Arai, Hisayuki; Hatano, Nobuyoshi; Yamaguchi, Katsuhiko; Katsunuma, Hideyo (Tokyo Medical Coll. (Japan))

    1990-06-01

    Since the introduction of CT scanning, correlations between neuropsychological findings and anatomical lesions have been studied. Anatomical studies by CT scans may, however, be misleading in delineating the extent of lesions in aphasia. We have carried out MRI (magnetic resonance imaging) and SPECT (single photon emission CT) examinations in 15 aphasic patients with cerebrovascular disease and discussed the usefulness of these studies. Compared to CT scan, MRI or SPECT studies were considered to be very useful in 8 of 15 patients. The useful points of these studies were: (1) easy detection of lesions with undetectable damages on CT, (2) demonstration of functional abnormalities in areas adjacent or distant from cerebrovascular lesions, and (3) precise definition of topographical abnormalities because of the three-dimensional imaging capability of MRI. As MRI or SPECT may define the actual extent of lesions and show areas of functional abnormality, these studies are useful and necessary in the assessment of lesions causing aphasia. (author).

  11. Usefulness of MRI and SPECT studies in evaluating the lesion of aphasia

    International Nuclear Information System (INIS)

    Hanyu, Haruo; Kobayashi, Yasutaka; Arai, Hisayuki; Hatano, Nobuyoshi; Yamaguchi, Katsuhiko; Katsunuma, Hideyo

    1990-01-01

    Since the introduction of CT scanning, correlations between neuropsychological findings and anatomical lesions have been studied. Anatomical studies by CT scans may, however, be misleading in delineating the extent of lesions in aphasia. We have carried out MRI (magnetic resonance imaging) and SPECT (single photon emission CT) examinations in 15 aphasic patients with cerebrovascular disease and discussed the usefulness of these studies. Compared to CT scan, MRI or SPECT studies were considered to be very useful in 8 of 15 patients. The useful points of these studies were: 1) easy detection of lesions with undetectable damages on CT, 2) demonstration of functional abnormalities in areas adjacent or distant from cerebrovascular lesions, and 3) precise definition of topographical abnormalities because of the three-dimensional imaging capability of MRI. As MRI or SPECT may define the actual extent of lesions and show areas of functional abnormality, these studies are useful and necessary in the assessment of lesions causing aphasia. (author)

  12. Usefulness of additional SPECT/CT identifying lymphatico-renal shunt in a patient with chyluria

    International Nuclear Information System (INIS)

    Suh, Min Seok; Cheon, Gi Jeong; Seo, Hyo Jung; KIm, Hyeon Hoe; Lee, Dong Soo

    2015-01-01

    Lymphoscintigraphy is known to be a useful and non-invasive modality for the evaluation of lymphatic abnormality. However, lymphoscintigraphy has limitations in evaluating chyluria because of its lack of anatomical information. Additional single-photon emission computed tomography (SPECT) combined with computed tomography (CT) was considered to be potentially helpful in detecting the abnormal lymphatico-renal communication. A 20-year-old male patient was referred to our hospital for evaluation of recurrent chyluria. During the third recurrence of chyluria, additional SPECT/CT along with lymphoscintigraphy was performed for evaluation. From the combined SPECT/CT images, lymphatic drainage of radiotracers to the kidney was well visualized, helping diagnosis of a patient with chyluria

  13. Quality control of analogue to digital conversion circuitry for artefact-free SPECT imaging

    International Nuclear Information System (INIS)

    Gillen, G.J.; Elliott, A.T.

    1992-01-01

    A simple method for the objective, quantitative assessment of analogue to digital conversion (ADC) differential linearity has been developed for SPECT imaging. The analytical approach uses the fact that a differential non-linearity in the ADC will produce a non-uniformity in the digitized image which has a well defined periodicity. This can be most clearly demonstrated in the frequency space domain by determining the Fourier transform of a thick profile which is taken through the centre of a flood field image. The accuracy of the method permits deteriorations in the performance of ADCs to be detected well before significant reductions in SPECT image quality are produced. The availability of a quantitative measure of ADC performance, which can be tested objectively using a simple data acquisition method, is of value in the specification, acceptance testing and general quality control of gamma camera SPECT systems. (author)

  14. Usefulness of additional SPECT/CT identifying lymphatico-renal shunt in a patient with chyluria

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Cheon, Gi Jeong; Seo, Hyo Jung; KIm, Hyeon Hoe; Lee, Dong Soo [Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-03-15

    Lymphoscintigraphy is known to be a useful and non-invasive modality for the evaluation of lymphatic abnormality. However, lymphoscintigraphy has limitations in evaluating chyluria because of its lack of anatomical information. Additional single-photon emission computed tomography (SPECT) combined with computed tomography (CT) was considered to be potentially helpful in detecting the abnormal lymphatico-renal communication. A 20-year-old male patient was referred to our hospital for evaluation of recurrent chyluria. During the third recurrence of chyluria, additional SPECT/CT along with lymphoscintigraphy was performed for evaluation. From the combined SPECT/CT images, lymphatic drainage of radiotracers to the kidney was well visualized, helping diagnosis of a patient with chyluria.

  15. Technical approach to improvement of SPECT images

    International Nuclear Information System (INIS)

    Fukukita, Hiroyoshi

    1985-01-01

    At present, a large number of SPECT systems are being widely used in Japan, hence, it is reasonable for us to know the physical and imaging characteristics of these SPECT devices, and also to recommend the optimum utility of SPECT systems. For this reason, a survey respect of characteristics of the commercialy available SPECT devices was carried out. In addition to this, various factors which have significant influence over SPECT image quality, such as, data acquisition matrix, reconstruction filter, γ-ray attenuation correction and daily quality control procedure, were also investigated. The materials used for this study are PET/SPECT phantom, Alderson liver phantom filled with Tc-99m solution, and either LFOV-E or ZLC-7500 interfaced to Scintipac 2400 minicomputer with 256 K byte of memory. Following are the results of this study. 1) The suitable data acquisition procedure was 128 x 128 matrix for linear sampling and approximately 64 views for angular sampling. 2) Reconstructed image using pre-processing filter with Wiener and Butterworth filters provided high quality image as compared with the Ramp filter. 3) Weighted backprojection method (WBP) proposed by Tanaka was superior to other methods, such as Sorenson method and Chang method in the object with non-uniform distribution of radionuclide. 4) It was found that uniformity correction of gamma camera and precise adjustment of the center of rotation are most important to maintain the images with a high quality. (author)

  16. C-Arm computed tomography adds diagnostic information in patients with chronic thromboembolic pulmonary hypertension and a positive V/Q SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Jan B.; Werncke, Thomas; Kaireit, Till [Hannover Medical School (Germany). Dept. for Diagnostic and Interventional Radiology; and others

    2017-01-15

    To determine if C-Arm computed tomography (CACT) has added diagnostic value in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH) with a positive mismatch pattern in ventilation/perfusion single photon emission computed tomography (V/Q SPECT). 28 patients (23 men, 5 women, 62±18 years) with CTEPH who had undergone SPECT, followed by CACT and right heart catheterization (RHC) were included. Two independent readers reviewed SPECT and CACT. Findings indicating CTEPH and their location (segmental or sub-segmental) were identified (V/Q mismatch in SPECT and vascular pathologies in CACT). Inter-modality agreement was calculated (Cohen's Kappa). Findings were scored on a 3-point-scale. The sum of the score (pulmonary artery CTEPH severity score (PACSS)) was calculated for each patient and imaging modality, correlated to RHC (spearman's correlation) and compared to the final therapeutic decision of the CTEPH board (including the consensus of SPECT, selective pulmonary DSA and CACT). Overall, 504 pulmonary artery segments were assessed in SPECT and CACT. SPECT had identified 266/504 (53%) arterial segments without and 238/504 (47%) segments with a V/Q mismatch indicating CTEPH. CACT detected 131/504 (26%) segments without abnormal findings and 373/504 (74%) segments with findings indicating CTEPH. Inter-modality agreement was fair (k=0.38). PACSS of CACT correlated mildly significantly with the mean pulmonary artery pressure (PAPmean; rho=0.48, p=0.01), while SPECT missed significance (rho=0.32, p=0.1). Discrepant findings were mostly attributed to a higher frequency of sub-segmental pulmonary arterial pathologies on CACT (145 sub-segmental findings indicating CTEPH) rated as normal on SPECT. In patients with CTEPH, contrast-enhanced CACT detects additional findings with a better correlation to the severity of PAPmean than V/Q SPECT. CACT indicates abnormalities even in segments without V/Q abnormalities.

  17. Geometric calibration method for multiple head cone beam SPECT systems

    International Nuclear Information System (INIS)

    Rizo, Ph.; Grangeat, P.; Guillemaud, R.; Sauze, R.

    1993-01-01

    A method is presented for performing geometric calibration on Single Photon Emission Tomography (SPECT) cone beam systems with multiple cone beam collimators, each having its own orientation parameters. This calibration method relies on the fact that, in tomography, for each head, the relative position of the rotation axis and of the collimator does not change during the acquisition. In order to ensure the method stability, the parameters to be estimated in intrinsic parameters and extrinsic parameters are separated. The intrinsic parameters describe the acquisition geometry and the extrinsic parameters position of the detection system with respect to the rotation axis. (authors) 3 refs

  18. Evaluation on effects of isradipine on renal protection by SPECT

    International Nuclear Information System (INIS)

    Xu Fengpo; Dong Shenan; Zhang Wei; Wu Xinghong; Lu Guoyuan

    1999-01-01

    The protective effects of isradipine on renal function were evaluated in a study on 40 patients with mild-moderate essential hypertension. Isradipine was administered at ado-sage of 2.5 mg twice daily for 4 weeks after receiving placebo for one week. SPECT were used for detecting renal function. The results of these evaluation indicated that there was significantly increasing in ERPF and GFR (P<0.01) and significant decreasing in resistance of renal vessel (P<0.01), and FF remained unchanged. It suggests that isradipine has a protective effect on renal function and it is beneficial for the long-term therapy

  19. Boron, phosphorus, and gallium determination in silicon crystals doped with gallium

    International Nuclear Information System (INIS)

    Shklyar, B.L.; Dankovskij, Yu.V.; Trubitsyn, Yu.V.

    1989-01-01

    When studying IR transmission spectra of silicon doped with gallium in the range of concentrations 1 x 10 14 - 5 x 10 16 cm -3 , the possibility to quantity at low (∼ 20 K) temperatures residual impurities of boron and phosphorus is ascertained. The lower determination limit of boron is 1 x 10 12 cm -3 for a sample of 10 nm thick. The level of the impurities in silicon crystals, grown by the Czochralski method and method of crucible-free zone melting, is measured. Values of boron and phosphorus concentrations prior to and after their alloying with gallium are compared

  20. A comparative study of perfusion CT and 99mTc-Hmpao spect measurement to assess cerebrovascular reserve capacity in patients with internal carotid artery occlusion

    Directory of Open Access Journals (Sweden)

    Eicker S

    2011-11-01

    Full Text Available Abstract Background and purpose Patients with internal carotid artery (ICA occlusion can demonstrate impaired cerebral vascular reserve (CVR. The detection of CVR using single photon emission CT (SPECT is nowadays widely accepted as a predictor in the diagnostic pathway in patients considered for cerebral revascularization. Recently perfusion CT (PCT gained widely acceptance in stroke imaging The present study was aimed at comparing the results of perfusion CT (PCT and 99mTc-HMPAO SPECT with acetazolamide challenge in patients with ICA occlusion. Methods 13 patients were included in the prospective evaluation. Both PCT and 99mTc-HMPAO SPECT were performed before and after the administration of acetazolamide. In detail, regional cerebral blood flow (rCBF, regional cerebral blood volume (rCBV, adapted time to peak (Tmax and mean transit times (MTT were compared with SPECT data. Results 99mTc-HMPAO SPECT demonstrated an impairment of CVR in six patients. A preserved CVR was present in seven patients. All patients with impaired CVR proven by SPECT had a delayed MTT (mean +2.98 s and a delayed Tmax (mean + 5.9 s, (both p Conclusion The prospective study demonstrated a highly significant correlation of perfusion parameters as' detected by 99mTc-HMPAO SPECT and the Tmax as detected by PCT in patients with ICA occlusion. Therefore this easy-to-perform technique seems to be an adequate method for the evaluation of cerebral perfusion in patients with ICA occlusion.

  1. Gallium scans in myasthenia gravis

    International Nuclear Information System (INIS)

    Swick, H.M.; Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether 67 Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on 67 Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis

  2. Gallium scans in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Swick, H.M. (Univ. of Kentucky, Lexington); Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether /sup 67/Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on /sup 67/Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis. (HLW)

  3. State and prospects of Russian and world gallium market

    Directory of Open Access Journals (Sweden)

    F. D. Larichkin

    2017-12-01

    Full Text Available The authors consider the state of Russian and world mineral and raw materials base of gallium, the main spheres of application in various branches and industries of the national economy. The article presents the generalization and analysis of trends in world and Russian production, consumption of rare metal and its compounds, the world trade and global market of gallium and products based on it, consuming it in new science-intensive innovative industries, including the production of military equipment. The unique chemical properties of gallium remained unclaimed for a long time. Only after the discovery of the semiconductor properties of gallium compounds has the situation radically changed: the rate of growth in production and consumption of metallic gallium at the end of the twentieth and beginning of the 21st century amounted to an average of more than 8% per year. The largest area of consumption of gallium is the production of semiconductor materials – gallium arsenide (GaAs and gallium nitride (GaN. The areas of application of gallium not related to the semiconductor industry are very small. Industry structure of consumption of GaAs and GaN: in integrated circuits is 66%; optoelectronic devices (light-emitting diodes, laser diodes, photodetectors and solar batteries – 20%; the remaining 14% – scientific research, special alloys, etc. Optoelectronic devices are used in aerospace industry, consumer goods, industrial and medical equipment and telecommunications. Integral circuits are used in the military industry, high-power computers and electronic communications. The most significant growing sectors of the market are LEDs, electronics based on gallium nitride and solar cells. Solar energy has become the fastest growing branch of the world economy. The volumes of gallium production in Russia do not correspond to its raw material, scientific and technological potential as the country and require the development activation based on state

  4. End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system

    International Nuclear Information System (INIS)

    Chan, Chung; Sinusas, Albert J; Liu, Chi; Harris, Mark; Le, Max; Biondi, James; Grobshtein, Yariv; Liu, Yi-Hwa

    2014-01-01

    Respiratory and cardiac motions can degrade myocardial perfusion SPECT (MPS) image quality and reduce defect detection and quantitative accuracy. In this study, we developed a dual respiratory and cardiac gating system for a high-resolution fully stationary cardiac SPECT scanner in order to improve the image quality and defect detection. Respiratory motion was monitored using a compressive sensor pillow connected to a dual respiratory–cardiac gating box, which sends cardiac triggers only during end-expiration phases to the single cardiac trigger input on the SPECT scanners. The listmode data were rebinned retrospectively into end-expiration frames for respiratory motion reduction or eight cardiac gates only during end-expiration phases to compensate for both respiratory and cardiac motions. The proposed method was first validated on a motion phantom in the presence and absence of multiple perfusion defects, and then applied on 11 patient studies with and without perfusion defects. In the normal phantom studies, the end-expiration gated SPECT (EXG-SPECT) reduced respiratory motion blur and increased myocardium to blood pool contrast by 51.2% as compared to the ungated images. The proposed method also yielded an average of 11.2% increase in myocardium to defect contrast as compared to the ungated images in the phantom studies with perfusion defects. In the patient studies, EXG-SPECT significantly improved the myocardium to blood pool contrast (p < 0.005) by 24% on average as compared to the ungated images, and led to improved perfusion uniformity across segments on polar maps for normal patients. For a patient with defect, EXG-SPECT improved the defect contrast and definition. The dual respiratory–cardiac gating further reduced the blurring effect, increased the myocardium to blood pool contrast significantly by 36% (p < 0.05) compared to EXG-SPECT, and further improved defect characteristics and visualization of fine structures at the expense of increased

  5. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    Energy Technology Data Exchange (ETDEWEB)

    Golestani, Reza; Dierckx, Rudi A.J.O. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); Wu, Chao [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Tio, Rene A. [University Medical Center Groningen, Thorax Center, Department of Cardiology, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Zeebregts, Clark J. [University Medical Center Groningen, Department of Surgery, Division of Vascular Surgery, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Petrov, Artiom D. [University of California, Irvine, Division of Cardiology, School of Medicine, Irvine, California (United States); Beekman, Freek J. [University Medical Center Utrecht, Image Sciences Institute and Rudolf Magnus Institute of Neurosciences, Utrecht (Netherlands); Delft University of Technology, Faculty of Applied Sciences, Section Radiation Detection and Medical Imaging, Delft (Netherlands); MILabs, Utrecht (Netherlands); Boersma, Hendrikus H. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Department of Clinical and Hospital Pharmacy, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands); Slart, Riemer H.J.A. [University Medical Center Groningen, Department of Nuclear Medicine and Molecular Imaging, Groningen (Netherlands); University Medical Center Groningen, Cardiovascular Imaging Group, P.O. Box 30001, Groningen (Netherlands)

    2010-09-15

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  6. Small-animal SPECT and SPECT/CT: application in cardiovascular research

    International Nuclear Information System (INIS)

    Golestani, Reza; Dierckx, Rudi A.J.O.; Wu, Chao; Tio, Rene A.; Zeebregts, Clark J.; Petrov, Artiom D.; Beekman, Freek J.; Boersma, Hendrikus H.; Slart, Riemer H.J.A.

    2010-01-01

    Preclinical cardiovascular research using noninvasive radionuclide and hybrid imaging systems has been extensively developed in recent years. Single photon emission computed tomography (SPECT) is based on the molecular tracer principle and is an established tool in noninvasive imaging. SPECT uses gamma cameras and collimators to form projection data that are used to estimate (dynamic) 3-D tracer distributions in vivo. Recent developments in multipinhole collimation and advanced image reconstruction have led to sub-millimetre and sub-half-millimetre resolution SPECT in rats and mice, respectively. In this article we review applications of microSPECT in cardiovascular research in which information about the function and pathology of the myocardium, vessels and neurons is obtained. We give examples on how diagnostic tracers, new therapeutic interventions, pre- and postcardiovascular event prognosis, and functional and pathophysiological heart conditions can be explored by microSPECT, using small-animal models of cardiovascular disease. (orig.)

  7. MRI and HMPAO-SPECT in the diagnosis of epilepsy

    International Nuclear Information System (INIS)

    Bokisch, A.; Gruenwald, F.; Elger, C.E.; Kaiser, W.A.; Biersack, H.J.

    1992-01-01

    Eighty-three patients suffering from intractable epilepsy were investigated by magnetic resonance imaging (MRI) and by HMPAO-SPECT during presurgical evaluation. MRI was proven to be most sensitive concerning the detection of focal lesions. Acquisition of thin slices and high signal/noise ratios are prerequisites for optimal sensitivity, the use of Gd-DTPA, in addition, increases the reliability slightly. Histological findings were available in 21 patients and in all cases of focal lesions without prior surgery, malignancy was detected or excluded correctly. The sensitivity was reduced, however, in the 4 patients with recurrency of astrocytoma. 2 cases were missed. Quantitative evaluation of signal intensities in the amygdala/hippocampal region or of the signal dynamics after contrast media application were not helpful in patients without focal lesion. In these patients no reliable criterium to determine the side of the focus with MRI investigations could be established. HMPAO-SPECT investigations were found to be complementary to MRI. In 19 of 36 patients without focal lesions the lateralisation was feasible by scintigraphy. In addition a correlation between the volume asymmetry of the temporal horns detected by MRI and the scintigraphic finding was established. The statistical proven correlation between the unilateral dilatation of the temporal horn and relative hypoperfusion is too weak, however, to imply individual consequences. (orig.) [de

  8. SPECT perfusion brain scintigraphy in dementia: early diagnostic and differential diagnostic

    International Nuclear Information System (INIS)

    Klisarova, A.

    2003-01-01

    The present review discusses the role of Single Photon Emission Computer Tomography (SPECT) and Positron Emission Tomography (PET) for the early detection and the differential diagnosis of the different types of dementia. The usefulness of the functional imaging is particularly emphasized in the detection of the early changes occurring in Alzheimer's diseases. The early diagnosis is a crucial factor for the treatment in the phase of reversible changes. The correlation between the severity of the diseases and the degree of hypoperfusion of the functional neuroimaging is also subject to review. SPECT and PET are of particular importance for the differential diagnosis of the various kinds of dementia. The imaging models are defined for the different stages of diseases. The functional imaging together with the clinical tests increase the diagnostic accuracy in Alzheimer's disease. The review presents the relation between the development of Alzheimer's disease and some risk factors. The review confirms the usefulness of SPECT and PET in the early diagnosis of Alzheimer's disease and the differential diagnosis of the different types of dementia which proves the SPECT appropriateness in the routine clinical practice. The brain structures are more advantageous than the other methods of visualisation (CT and MRI) for the detection of the functional disorders in the brain cortex in a number of diseases of the central nervous system. (author)

  9. Design of common software for quality control of SPECT

    International Nuclear Information System (INIS)

    Li Xiaohua; Gao Ruzhen; Chen Shengzu

    1993-01-01

    The goal of this study is to design a common testing system for SPECT quality control according to NEMA standard. Using the system, the performances of different types of SPECT can be tested, so that the acceptance testing, performance comparing and routine quality control for SPECT can be normalized. The system was based on IBM PC series of microcomputer. Testing data are acquired from various types of SPECT, then transferred into IBM PC through interface and tested with an unique testing program. Two parts were included: interface and SPECT testing program. It emphatically studied the managing program of RS232 interface, designing skills and the mathematic patterns of SPECT testing program. The system which was composed of 11 subroutines can be used to measure the performances for both gamma camera and SPECT. The system was tested on OMEGA 500/MCS 560 SPECT and the results showed that it is effective, accurate and easy to use

  10. Automated realization of the gallium melting and triple points

    Science.gov (United States)

    Yan, X.; Duan, Y.; Zhang, J. T.; Wang, W.

    2013-09-01

    In order to improve the automation and convenience of the process involved in realizing the gallium fixed points, an automated apparatus, based on thermoelectric and heat pipe technologies, was designed and developed. This paper describes the apparatus design and procedures for freezing gallium mantles and realizing gallium melting and triple points. Also, investigations on the melting behavior of a gallium melting point cell and of gallium triple point cells were carried out while controlling the temperature outside the gallium point cells at 30 °C, 30.5 °C, 31 °C, and 31.5 °C. The obtained melting plateau curves show dentate temperature oscillations on the melting plateaus for the gallium point cells when thermal couplings occurred between the outer and inner liquid-solid interfaces. The maximum amplitude of the temperature fluctuations was about 1.5 mK. Therefore, the temperature oscillations can be used to indicate the ending of the equilibrium phase transitions. The duration and amplitude of such temperature oscillations depend on the temperature difference between the setting temperature and the gallium point temperature; the smaller the temperature difference, the longer the duration of both the melting plateaus and the temperature fluctuations.

  11. Indium Gallium Nitride Multijunction Solar Cell Simulation Using Silvaco Atlas

    Science.gov (United States)

    2007-06-01

    models is of great interest in space applications. By increasing the efficiency of photovoltaics, the number of solar panels is decreased. Therefore...obtained in single-junction solar cells by using Gallium Arsenide. Monocrystalline Gallium Arsenide has a maximum efficiency of approximately 25.1% [10

  12. State of rare earth impurities in gallium and indium antimonides

    International Nuclear Information System (INIS)

    Evgen'ev, S.B.; Kuz'micheva, G.M.

    1990-01-01

    State of rare earth impurities in indium and gallium antimonides was studied. Results of measuring density and lattice parameter of samples in GaSb-rare earth and InSb-rare earth systems are presented. It is shown that during rare earth dissolution in indium and gallium antimonides rare earth atoms occupy interstitial positions or, at least, are displaced from lattice points

  13. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  14. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  15. Study on localization diagnosis with SPECT rCBF image in childhood epilepsy: in comparison with EEG and MRI findings

    International Nuclear Information System (INIS)

    Wu Meiqian; Tang Jihong; Wu Jinchang; Shi Yizhen

    1999-01-01

    Objective: To evaluate the diagnostic value of SPECT rCBF imaging in localization of childhood epileptic foci. Methods: rCBF imaging was performed in 74 epileptic patients not in seizure and 10 epileptic patients right in seizure. EEG was performed in 84, MRI in 67 of the subjects mentioned above. All the results of three modalities were compared with each other. Results: The highest positive rate (82.14%) was found in SPECT rCBF imaging, the positive rate in EEG or MRI was 71.43 or 47.76%. The epileptic foci localized by EEG (60 abnormalities) and by MRI (32 abnormalities) were 70.59% or 58.82% in concordance with those by SPECT, respectively. Conclusions: SPECT rCBF imaging is a sensitive and effective method for epileptic foci localization. It may have some advantages over EEG and MRI in detecting and localizing epileptic foci. However, abnormal SPECT areas may cover some abnormalities which do not belong to epileptic category. A combination of these three methods (SPECT, EEG and MRI) will improve the positive rate and accuracy for localizing

  16. The accuracy of myocardial perfusion SPECT imaging in the evaluation of coronary artery disease in women and men

    International Nuclear Information System (INIS)

    Kaminek, M.; Myslivecek, M.; Huyak, V.; Koranda, P.; Skvarilova, M.; Ostransky, J.

    2001-01-01

    The purpose of this study is to compare sensitivity, specificity and accuracy of myocardial perfusion SPECT for the detection of coronary artery disease (CAD) in women and men. 588 patients (455 males and 133 females, 273 after a previous myocardial infarction) underwent stress myocardial perfusion SPECT. The accuracy of myocardial perfusion SPECT was proved by coronary angiography (stenosis >50% was considered as a CAD). The sensitivity of SPECT was slightly higher, but statistically not significant, in men than in women (94% versus 91%, p > 0.05). The specificity was higher in women than in men (93% versus 82%), but this difference was not statistically significant either (p > 0.05). The accuracy of SPECT was the same for both sexes (92%). In angiographically verified group of patients the selection bias was obvious - patients with CAD dominated (74%) and the fraction of patients with CAD in men's group (83%) was significantly higher than in women's group (50%), p < 0.05. No significant difference was revealed in the accuracy of myocardial perfusion SPECT in men and women. Our results are in accordance with the prevailing opinion in literature that discovered differences in sensitivity, specificity and diagnostic accuracy are usually not statistically significant or that they can be explained by the selection bias of patients in angiographically verified groups (significantly higher fraction of patients with CAD in men's group). (author)

  17. The Value of Attenuation Correction in Hybrid Cardiac SPECT/CT on Inferior Wall According to Body Mass Index

    International Nuclear Information System (INIS)

    Tamam, Muge; Mulazimoglu, Mehmet; Edis, Nurcan; Ozpacaci, Tevfik

    2016-01-01

    The purpose of this study was to evaluate the diagnostic value of attenuation-corrected single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) on the inferior wall compared to uncorrected (NC) SPECT MPI between obese and nonobese patients. A total of 157 consecutive patients (122 males and 35 females, with median age: 57.4 ± 11 years) who underwent AC technetium 99m-methoxyisobutylisonitrile (AC Tc99m-sestamibi) SPECT MPI were included to the study. A hybrid SPECT and transmission computed tomography (CT) system was used for the diagnosis with 1-day protocol, and stress imaging was performed first. During attenuation correction (AC) processing on a Xeleris Workstation using Myovation cardiac software with ordered subset expectation maximization (OSEM), iterative reconstruction with attenuation correction (IRAC) and NC images filtered back projection (FBP) were used. For statistical purposes, P < 0.05 was considered significant. This study included 73 patients with body mass index (BMI) <30 and 84 patients with BMI ≥ 30. In patients with higher BMI, increased amount of both visual and semiquantitative attenuation of the inferior wall was detected. IRAC reconstruction corrects the diaphragm attenuation of the inferior wall better than FBP. AC with OSEM iterative reconstruction significantly improves the diagnostic value of stress-only SPECT MPI in patients with normal weight and those who are obese, but the improvements are significantly greater in obese patients. Stress-only SPECT imaging with AC provides shorter and lower radiation exposure

  18. The added value of SPECT-CT for the identification of sentinel lymph nodes in early stage oral cancer

    International Nuclear Information System (INIS)

    Toom, Inne J. den; Bree, Remco de; Schie, Annelies van; Hoekstra, Otto S.; Weert, Stijn van; Karagozoglu, K.H.; Bloemena, Elisabeth

    2017-01-01

    To assess the role of single-photon emission computed tomography with computed tomography (SPECT-CT) for the identification of sentinel lymph nodes (SLNs) in patients with early stage (T1-T2) oral cancer and a clinically negative neck (cN0). In addition to planar lymphoscintigraphy, SPECT-CT was performed in 66 consecutive patients with early stage oral cancer and a clinically negative neck. The addition of SPECT-CT to planar images was retrospectively analyzed for the number of additional SLNs, more precise localization of SLNs, and importance of anatomical information by a team consisting of a nuclear physician, surgeon, and investigator. Identification rate for both imaging modalities combined was 98% (65/66). SPECT-CT identified 15 additional SLNs in 14 patients (22%). In 2/15 (13%) of these additional SLNs, the only metastasis was found, resulting in an upstaging rate of 3% (2/65). In 20% of the patients with at least one positive SLN, the only positive SLN was detected due to the addition of SPECT-CT. SPECT-CT was considered to add important anatomical information in two patients (3%). In 5/65 (8%) of the patients initially scored SLNs on planar lymphoscintigrams were scored as non-SLNs when SPECT-CT was added. There were four false-negative SLN biopsy procedures in this cohort. The addition of SPECT-CT to planar lymphoscintigraphy is recommended for the identification of more (positive) SLNs and better topographical orientation for surgery in sentinel lymph node biopsy for early stage oral cancer. (orig.)

  19. Apparent CBF decrease with normal aging due to partial volume effects: MR-based partial volume correction on CBF SPECT.

    Science.gov (United States)

    Inoue, Kentaro; Ito, Hiroshi; Goto, Ryoi; Nakagawa, Manabu; Kinomura, Shigeo; Sato, Tachio; Sato, Kazunori; Fukuda, Hiroshi

    2005-06-01

    Several studies using single photon emission tomography (SPECT) have shown changes in cerebral blood flow (CBF) with age, which were associated with partial volume effects by some authors. Some studies have also demonstrated gender-related differences in CBF. The present study aimed to examine age and gender effects on CBF SPECT images obtained using the 99mTc-ethyl cysteinate dimer and a SPECT scanner, before and after partial volume correction (PVC) using magnetic resonance (MR) imaging. Forty-four healthy subjects (29 males and 15 females; age range, 27-64 y; mean age, 50.0 +/- 9.8 y) participated. Each MR image was segmented to yield grey and white matter images and coregistered to a corresponding SPECT image, followed by convolution to approximate the SPECT spatial resolution. PVC-SPECT images were produced using the convoluted grey matter MR (GM-MR) and white matter MR images. The age and gender effects were assessed using SPM99. Decreases with age were detected in the anterolateral prefrontal cortex and in areas along the lateral sulcus and the lateral ventricle, bilaterally, in the GM-MR images and the SPECT images. In the PVC-SPECT images, decreases in CBF in the lateral prefrontal cortex lost their statistical significance. Decreases in CBF with age found along the lateral sulcus and the lateral ventricle, on the other hand, remained statistically significant, but observation of the spatially normalized MR images suggests that these findings are associated with the dilatation of the lateral sulcus and lateral ventricle, which was not completely compensated for by the spatial normalization procedure. Our present study demonstrated that age effects on CBF in healthy subjects could reflect morphological differences with age in grey matter.

  20. The added value of SPECT-CT for the identification of sentinel lymph nodes in early stage oral cancer

    Energy Technology Data Exchange (ETDEWEB)

    Toom, Inne J. den; Bree, Remco de [VU University Medical Center, Department of Otolaryngology-Head and Neck Surgery, Amsterdam (Netherlands); UMC Utrecht Cancer Center, University Medical Center, Department of Head and Neck Surgical Oncology, PO Box 85500, Utrecht (Netherlands); Schie, Annelies van; Hoekstra, Otto S. [VU University Medical Center, Department of Radiology and Nuclear Medicine, Amsterdam (Netherlands); Weert, Stijn van [VU University Medical Center, Department of Otolaryngology-Head and Neck Surgery, Amsterdam (Netherlands); Karagozoglu, K.H. [VU University Medical Center/Academic Centre for Dentistry (ACTA) Amsterdam, Department of Oral and Maxillofacial Surgery/Oral Pathology, Amsterdam (Netherlands); Bloemena, Elisabeth [VU University Medical Center/Academic Centre for Dentistry (ACTA) Amsterdam, Department of Oral and Maxillofacial Surgery/Oral Pathology, Amsterdam (Netherlands); VU University Medical Center, Department of Pathology, Amsterdam (Netherlands)

    2017-06-15

    To assess the role of single-photon emission computed tomography with computed tomography (SPECT-CT) for the identification of sentinel lymph nodes (SLNs) in patients with early stage (T1-T2) oral cancer and a clinically negative neck (cN0). In addition to planar lymphoscintigraphy, SPECT-CT was performed in 66 consecutive patients with early stage oral cancer and a clinically negative neck. The addition of SPECT-CT to planar images was retrospectively analyzed for the number of additional SLNs, more precise localization of SLNs, and importance of anatomical information by a team consisting of a nuclear physician, surgeon, and investigator. Identification rate for both imaging modalities combined was 98% (65/66). SPECT-CT identified 15 additional SLNs in 14 patients (22%). In 2/15 (13%) of these additional SLNs, the only metastasis was found, resulting in an upstaging rate of 3% (2/65). In 20% of the patients with at least one positive SLN, the only positive SLN was detected due to the addition of SPECT-CT. SPECT-CT was considered to add important anatomical information in two patients (3%). In 5/65 (8%) of the patients initially scored SLNs on planar lymphoscintigrams were scored as non-SLNs when SPECT-CT was added. There were four false-negative SLN biopsy procedures in this cohort. The addition of SPECT-CT to planar lymphoscintigraphy is recommended for the identification of more (positive) SLNs and better topographical orientation for surgery in sentinel lymph node biopsy for early stage oral cancer. (orig.)

  1. Thermal Plasma Synthesis of Crystalline Gallium Nitride Nanopowder from Gallium Nitrate Hydrate and Melamine

    Directory of Open Access Journals (Sweden)

    Tae-Hee Kim

    2016-02-01

    Full Text Available Gallium nitride (GaN nanopowder used as a blue fluorescent material was synthesized by using a direct current (DC non-transferred arc plasma. Gallium nitrate hydrate (Ga(NO33∙xH2O was used as a raw material and NH3 gas was used as a nitridation source. Additionally, melamine (C3H6N6 powder was injected into the plasma flame to prevent the oxidation of gallium to gallium oxide (Ga2O3. Argon thermal plasma was applied to synthesize GaN nanopowder. The synthesized GaN nanopowder by thermal plasma has low crystallinity and purity. It was improved to relatively high crystallinity and purity by annealing. The crystallinity is enhanced by the thermal treatment and the purity was increased by the elimination of residual C3H6N6. The combined process of thermal plasma and annealing was appropriate for synthesizing crystalline GaN nanopowder. The annealing process after the plasma synthesis of GaN nanopowder eliminated residual contamination and enhanced the crystallinity of GaN nanopowder. As a result, crystalline GaN nanopowder which has an average particle size of 30 nm was synthesized by the combination of thermal plasma treatment and annealing.

  2. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  3. Gallium-containing hydroxyapatite for potential use in orthopedics

    International Nuclear Information System (INIS)

    Melnikov, P.; Teixeira, A.R.; Malzac, A.; Coelho, M. de B.

    2009-01-01

    A novel material that may be recommended for grafts and implants stimulating bone growth has been obtained by introducing gallium ions (up to 11.0 mass%) into crystalline lattice of hydroxyapatite. The doping was carried out using gallium nitrate and sodium gallate solutions. In both cases, lattice parameters of gallium-doped hydroxyapatite are identical to those of pure synthetic hydroxyapatite. Gallium does not replace calcium as a result of heterovalent substitution and consequently produces no distortions in the framework of hydroxyapatite matrix. It remains strongly fixed in the form of solid solution of intercalation. According to scanning electron microscopy images gallium insertion does not cause any morphological alterations in hydroxyapatite structure and the product developed meets physico-chemical criteria for biomaterial to be employed in orthopedic practice and local handling of traumatic injuries. Its future usage opens the opportunity to enhance osteosynthesis and calcium retention in loco.

  4. Nuclear microprobe imaging of gallium nitrate in cancer cells

    Science.gov (United States)

    Ortega, Richard; Suda, Asami; Devès, Guillaume

    2003-09-01

    Gallium nitrate is used in clinical oncology as treatment for hypercalcemia and for cancer that has spread to the bone. Its mechanism of antitumor action has not been fully elucidated yet. The knowledge of the intracellular distribution of anticancer drugs is of particular interest in oncology to better understand their cellular pharmacology. In addition, most metal-based anticancer compounds interact with endogenous trace elements in cells, altering their metabolism. The purpose of this experiment was to examine, by use of nuclear microprobe analysis, the cellular distribution of gallium and endogenous trace elements within cancer cells exposed to gallium nitrate. In a majority of cellular analyses, gallium was found homogeneously distributed in cells following the distribution of carbon. In a smaller number of cells, however, gallium appeared concentrated together with P, Ca and Fe within round structures of about 2-5 μm diameter located in the perinuclear region. These intracellular structures are typical of lysosomial material.