WorldWideScience

Sample records for future high intense

  1. Beam instrumentation for future high intense hadron accelerators at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Wendt, M.; Hu, M.; Tassotto, G.; Thurman-Keup, R.; Scarpine, V.; Shin, S.; Zagel, J.; /Fermilab

    2008-08-01

    High intensity hadron beams of up to 2 MW beam power are a key element of new proposed experimental facilities at Fermilab. Project X, which includes a SCRF 8 GeV H{sup -} linac, will be the centerpiece of future HEP activities in the neutrino sector. After a short overview of this, and other proposed projects, we present the current status of the beam instrumentation activities at Fermilab with a few examples. With upgrades and improvements they can meet the requirements of the new beam facilities, however design and development of new instruments is needed, as shown by the prototype and conceptual examples in the last section.

  2. Future Perspectives in Nuclear Structure: From high intensity stable to radioactive nuclear beams

    Science.gov (United States)

    de Angelis, Giacomo

    2005-04-01

    Future perspectives in nuclear structure rely on radioactive nuclear beams as well as on high intensity beams of stable ions. Especially for neutron rich nuclei, deep-inelastic and multi-nucleon transfer reactions can be used to populate yrast and non yrast states. Particularly powerful is here the combination of large acceptance spectrometers with highly segmented γ-detector arrays. Such devices, eventually complemented by large cov- erage particle detectors, can provide the necessary channel selectivity to identify very rare signals. An example is the CLARA γ-ray detector array coupled with the PRISMA spectrometer at the Legnaro National Laboratories (LNL). The physics aims achievable with this setup will complement studies performed with current radioactive beam (RIB) facilities. With such set-up we have recently investigated the stability of the N=50 shell closure when moving towards more exotic systems. Here the comparison of the experi- mental data with shell model calculations seems to indicate a persistence of the N=50 shell gap down to Z=32. Future perspectives at LNL are based on an increase in in- tensity as well as on the availability of heavy ion species. Beams like 136Xe or 208Pb, which will be provided by the new PIAVE injector, can be used to drive the multinucleon flux toward the more exotic regions. Moreover a new ISOL facility (SPES) dedicated to the production and acceleration of radioactive neutron rich species is now under develop- ment at LNL. It will be based on an high intensity proton and deuteron LINAC. Induced fission fragments will be ionized and then accelerated using the presently existing super- conductive LINAC (ALPI). Among the new instrumentation the concept of γ-ray tracking has been recently introduced in nuclear spectroscopy. Detectors based on γ-ray tracking have position resolution capabilities with excellent performances both in efficiency and in achievable Doppler correction. A new γ-ray detector array (AGATA) based on

  3. [The future of intensive medicine].

    Science.gov (United States)

    Palencia Herrejón, E; González Díaz, G; Mancebo Cortés, J

    2011-05-01

    Although Intensive Care Medicine is a young specialty compared with other medical disciplines, it currently plays a key role in the process of care for many patients. Experience has shown that professionals with specific training in Intensive Care Medicine are needed to provide high quality care to critically ill patients. In Europe, important steps have been taken towards the standardization of training programs of the different member states. However, it is now necessary to take one more step forward, that is, the creation of a primary specialty in Intensive Care Medicine. Care of the critically ill needs to be led by specialists who have received specific and complete training and who have the necessary professional competences to provide maximum quality care to their patients. The future of the specialty presents challenges that must be faced with determination, with the main objective of meeting the needs of the population.

  4. [High-intensity focused ultrasound and prostate cancer: technology, state of the art and future].

    Science.gov (United States)

    Vespasiani, G; Asimakopoulos, A D; Finazzi Agrò, E; Virgili, G

    2008-01-01

    BACKGROUND. The potential applications of the high-intensity focused ultrasound (HIFU) as a minimally invasive therapy of the localized prostate cancer explain the growing interest of the urologic community towards this technique. HIFU has been assessed for its role in the treatment of localized prostate cancer in patients who otherwise would not have benefited from surgery, and in local recurrences after radiation failure. Methods. Relevant information on HIFU treatment was identified through a literature search of published studies. RESULTS. High biochemical efficacy, excellent tumor local control and favorable mid- and long-term oncological data with a low morbidity rate have been shown in many series of patients. CONCLUSIONS. Although HIFU is a recent and emerging technology, it has been well studied and developed to a point that HIFU will undoubtedly be an effective alternative to radiation therapy.

  5. MRI methods for the evaluation of high intensity focused ultrasound tumor treatment: Current status and future needs.

    Science.gov (United States)

    Hectors, Stefanie J C G; Jacobs, Igor; Moonen, Chrit T W; Strijkers, Gustav J; Nicolay, Klaas

    2016-01-01

    Thermal ablation with high intensity focused ultrasound (HIFU) is an emerging noninvasive technique for the treatment of solid tumors. HIFU treatment of malignant tumors requires accurate treatment planning, monitoring and evaluation, which can be facilitated by performing the procedure in an MR-guided HIFU system. The MR-based evaluation of HIFU treatment is most often restricted to contrast-enhanced T1 -weighted imaging, while it has been shown that the non-perfused volume may not reflect the extent of nonviable tumor tissue after HIFU treatment. There are multiple studies in which more advanced MRI methods were assessed for their suitability for the evaluation of HIFU treatment. While several of these methods seem promising regarding their sensitivity to HIFU-induced tissue changes, there is still ample room for improvement of MRI protocols for HIFU treatment evaluation. In this review article, we describe the major acute and delayed effects of HIFU treatment. For each effect, the MRI methods that have been-or could be-used to detect the associated tissue changes are described. In addition, the potential value of multiparametric MRI for the evaluation of HIFU treatment is discussed. The review ends with a discussion on future directions for the MRI-based evaluation of HIFU treatment.

  6. MRI methods for the evaluation of high intensity focused ultrasound tumor treatment : Current status and future needs

    NARCIS (Netherlands)

    Hectors, Stefanie J C G; Jacobs, Igor; Moonen, Chrit T W; Strijkers, Gustav J; Nicolay, Klaas

    2016-01-01

    Thermal ablation with high intensity focused ultrasound (HIFU) is an emerging noninvasive technique for the treatment of solid tumors. HIFU treatment of malignant tumors requires accurate treatment planning, monitoring and evaluation, which can be facilitated by performing the procedure in an MR-gui

  7. Climate-change driven increase in high intensity rainfall events: Analysis of development in the last decades and towards an extrapolation of future progression

    Science.gov (United States)

    Müller, Eva; Pfister, Angela; Gerd, Büger; Maik, Heistermann; Bronstert, Axel

    2015-04-01

    Hydrological extreme events can be triggered by rainfall on different spatiotemporal scales: river floods are typically caused by event durations of between hours and days, while urban flash floods as well as soil erosion or contaminant transport rather result from storms events of very short duration (minutes). Still, the analysis of climate change impacts on rainfall-induced extreme events is usually carried out using daily precipitation data at best. Trend analyses of extreme rainfall at sub-daily or even sub-hourly time scales are rare. In this contribution two lines of research are combined: first, we analyse sub-hourly rainfall data for several decades in three European regions.Second, we investigate the scaling behaviour of heavy short-term precipitation with temperature, i.e. the dependence of high intensity rainfall on the atmospheric temperature at that particular time and location. The trend analysis of high-resolution rainfall data shows for the first time that the frequency of short and intensive storm events in the temperate lowland regions in Germany has increased by up to 0.5 events per year over the last decades. I.e. this trend suggests that the occurrence of these types of storms have multiplied over only a few decades. Parallel to the changes in the rainfall regime, increases in the annual and seasonal average temperature and changes in the occurrence of circulation patterns responsible for the generation of high-intensity storms have been found. The analysis of temporally highly resolved rainfall records from three European regions further indicates that extreme precipitation events are more intense with warmer temperatures during the rainfall event. These observations follow partly the Clausius-Clapeyron relation. Based on this relation one may derive a general rule of maximum rainfall intensity associated to the event temperature, roughly following the Clausius-Clapeyron (CC) relation. This rule might be used for scenarios of future maximum

  8. [The future of pediatric intensive care].

    Science.gov (United States)

    Biarent, D; Otte, F; Fonteyne, C; Khalil, T

    2006-01-01

    Paediatric intensive care is born 40 years ago. It has been shown that admission of critically ill children in intensive care (ICU) where no paediatric intensivists worked increased significantly the mortality and the length of stay. The recognition of Paediatric Intensive Care (PICU) does not exist in Belgium and children are admitted in both adult and paediatric intensive care units. It is mandatory to recognise the PICU specificity and the usefulness of a fellowship in paediatric intensive care. Development of molecular biology and genetics will permit in the near future to understand reversible and irreversible cellular processes of the majority of problems responsible for mortality in critical care and to allow the development of new diagnostic and therapeutic techniques. Rapid development of information will permit the creation of multicenter databases including all PICU's data. The final goal is an intelligent tool for making decision process. Telemedecine is born which permits a virtual consultation of the patient. Technological progress must not impair the wellbeing of the child and its family. The PICU of the future must be "parents admitted". PICU profile is progressively changing, the way of taking care of the critically ill child and its family is also changing and improving. An ethical reflexion among the health care providers' team and a dialogue with parents will blossom.

  9. Studies of equation of state properties of high-energy density matter using intense heavy ion beams at the future FAIR facility: The HEDgeHOB collaboration

    Energy Technology Data Exchange (ETDEWEB)

    Tahir, N.A. [Gesellschaft fuer Schwerionenforschung Darmstadt, 64291 Darmstadt (Germany)]. E-mail: n.tahir@gsi.de; Spiller, P. [Gesellschaft fuer Schwerionenforschung Darmstadt, 64291 Darmstadt (Germany); Udrea, S. [Institut fuer Kernphysik, TU Darmstadt, 64289 Darmstadt (Germany); Cortazar, O.D. [ETSI Industriales, Universidad de Castilla-La Mancha, 13071 Ciudad Real (Spain); Deutsch, C. [LPGP, Universite Paris-Sud, 91405 Orsay (France); Fortov, V.E. [Institute for Problems in Chemical Physics, Chernogolovka (Russian Federation); Gryaznov, V. [Institute for Problems in Chemical Physics, Chernogolovka (Russian Federation); Hoffmann, D.H.H. [Gesellschaft fuer Schwerionenforschung Darmstadt, 64291 Darmstadt (Germany); Institut fuer Kernphysik, TU Darmstadt, 64289 Darmstadt (Germany); Lomonosov, I.V. [Institute for Problems in Chemical Physics, Chernogolovka (Russian Federation); Ni, P. [Institut fuer Kernphysik, TU Darmstadt, 64289 Darmstadt (Germany); Piriz, A.R. [ETSI Industriales, Universidad de Castilla-La Mancha, 13071 Ciudad Real (Spain); Shutov, A. [Institute for Problems in Chemical Physics, Chernogolovka (Russian Federation); Temporal, M. [ETSI Industriales, Universidad de Castilla-La Mancha, 13071 Ciudad Real (Spain); Varentsov, D. [Institut fuer Kernphysik, TU Darmstadt, 64289 Darmstadt (Germany)

    2006-04-15

    This paper shows with the help of numerical simulations the capabilities of intense heavy ion beams to induce states of high-energy density (HED) in matter. Two different experimental schemes are considered, namely, HIHEX (heavy ion heating and expansion) and LAPLAS (laboratory planetary sciences). The first scheme considers isochoric heating and subsequent isentropic expansion of matter while the latter deals with low entropy compression of matter using multiple shock reflection technique. This work has been done within the framework of the HEDgeHOB (high-energy density matter generated by heavy ion beams) collaboration that has been formed to organize and facilitate construction of experimental facilities and later to perform experimental work in the field of HED matter at the future FAIR (facility for antiprotons and ion research) facility.

  10. Studies of equation of state properties of high-energy density matter using intense heavy ion beams at the future FAIR facility: The HEDgeHOB collaboration

    Science.gov (United States)

    Tahir, N. A.; Spiller, P.; Udrea, S.; Cortazar, O. D.; Deutsch, C.; Fortov, V. E.; Gryaznov, V.; Hoffmann, D. H. H.; Lomonosov, I. V.; Ni, P.; Piriz, A. R.; Shutov, A.; Temporal, M.; Varentsov, D.

    2006-04-01

    This paper shows with the help of numerical simulations the capabilities of intense heavy ion beams to induce states of high-energy density (HED) in matter. Two different experimental schemes are considered, namely, HIHEX (heavy ion heating and expansion) and LAPLAS (laboratory planetary sciences). The first scheme considers isochoric heating and subsequent isentropic expansion of matter while the latter deals with low entropy compression of matter using multiple shock reflection technique. This work has been done within the framework of the HEDgeHOB (high-energy density matter generated by heavy ion beams) collaboration that has been formed to organize and facilitate construction of experimental facilities and later to perform experimental work in the field of HED matter at the future FAIR (facility for antiprotons and ion research) facility.

  11. The future of intensive care medicine.

    Science.gov (United States)

    Blanch, L; Annane, D; Antonelli, M; Chiche, J D; Cuñat, J; Girard, T D; Jiménez, E J; Quintel, M; Ugarte, S; Mancebo, J

    2013-03-01

    Intensive care medical training, whether as a primary specialty or as secondary add-on training, should include key competences to ensure a uniform standard of care, and the number of intensive care physicians needs to increase to keep pace with the growing and anticipated need. The organisation of intensive care in multiple specialty or central units is heterogeneous and evolving, but appropriate early treatment and access to a trained intensivist should be assured at all times, and intensivists should play a pivotal role in ensuring communication and high-quality care across hospital departments. Structures now exist to support clinical research in intensive care medicine, which should become part of routine patient management. However, more translational research is urgently needed to identify areas that show clinical promise and to apply research principles to the real-life clinical setting. Likewise, electronic networks can be used to share expertise and support research. Individuals, physicians and policy makers need to allow for individual choices and priorities in the management of critically ill patients while remaining within the limits of economic reality. Professional scientific societies play a pivotal role in supporting the establishment of a defined minimum level of intensive health care and in ensuring standardised levels of training and patient care by promoting interaction between physicians and policy makers. The perception of intensive care medicine among the general public could be improved by concerted efforts to increase awareness of the services provided and of the successes achieved.

  12. Landscape of Future Accelerators at the Energy and Intensity Frontier

    Energy Technology Data Exchange (ETDEWEB)

    Syphers, M. J. [Northern Illinois U.; Chattopadhyay, S. [Northern Illinois U.

    2016-11-21

    An overview is provided of the currently envisaged landscape of charged particle accelerators at the energy and intensity frontiers to explore particle physics beyond the standard model via 1-100 TeV-scale lepton and hadron colliders and multi-Megawatt proton accelerators for short- and long- baseline neutrino experiments. The particle beam physics, associated technological challenges and progress to date for these accelerator facilities (LHC, HL-LHC, future 100 TeV p-p colliders, Tev-scale linear and circular electron-positron colliders, high intensity proton accelerator complex PIP-II for DUNE and future upgrade to PIP-III) are outlined. Potential and prospects for advanced “nonlinear dynamic techniques” at the multi-MW level intensity frontier and advanced “plasma- wakefield-based techniques” at the TeV-scale energy frontier and are also described.

  13. High intensity protons in RHIC

    Energy Technology Data Exchange (ETDEWEB)

    Montag, C.; Ahrens, L.; Blaskiewicz, M.; Brennan, J. M.; Drees, K. A.; Fischer, W.; Huang, H.; Minty, M.; Robert-Demolaize, G.; Thieberger, P.; Yip, K.

    2012-01-05

    During the 2012 summer shutdown a pair of electron lenses will be installed in RHIC, allowing the beam-beam parameter to be increased by roughly 50 percent. To realize the corresponding luminosity increase bunch intensities have to be increased by 50 percent, to 2.5 {center_dot} 10{sup 11} protons per bunch. We list the various RHIC subsystems that are most affected by this increase, and propose beam studies to ensure their readiness. The proton luminosity in RHIC is presently limited by the beam-beam effect. To overcome this limitation, electron lenses will be installed in IR10. With the help of these devices, the headon beam-beam kick experienced during proton-proton collisions will be partially compensated, allowing for a larger beam-beam tuneshift at these collision points, and therefore increasing the luminosity. This will be accomplished by increasing the proton bunch intensity from the presently achieved 1.65 {center_dot} 10{sup 11} protons per bunch in 109 bunches per beam to 2.5 {center_dot} 10{sup 11}, thus roughly doubling the luminosity. In a further upgrade we aim for bunch intensities up to 3 {center_dot} 10{sup 11} protons per bunch. With RHIC originally being designed for a bunch intensity of 1 {center_dot} 10{sup 11} protons per bunch in 56 bunches, this six-fold increase in the total beam intensity by far exceeds the design parameters of the machine, and therefore potentially of its subsystems. In this note, we present a list of major subsystems that are of potential concern regarding this intensity upgrade, show their demonstrated performance at present intensities, and propose measures and beam experiments to study their readiness for the projected future intensities.

  14. LHC Report: reaching high intensity

    CERN Multimedia

    Jan Uythoven

    2015-01-01

    After both beams having been ramped to their full energy of 6.5 TeV, the last two weeks saw the beam commissioning process advancing on many fronts. An important milestone was achieved when operators succeeded in circulating a nominal-intensity bunch. During the operation, some sudden beam losses resulted in beam dumps at top energy, a problem that needed to be understood and resolved.   In 2015 the LHC will be circulating around 2800 bunches in each beam and each bunch will contain just over 1 x 1011 protons. Until a few days ago commissioning was taking place with single bunches of 5 x 109 protons. The first nominal bunch with an intensity of 1 x 1011 protons was injected on Tuesday, 21 April. In order to circulate such a high-intensity bunch safely, the whole protection system must be working correctly: collimators, which protect the aperture, are set at preliminary values known as coarse settings; all kicker magnets for injecting and extracting the beams are commissioned with beam an...

  15. High intensity focused ultrasound (HIFU) applied to hepato-bilio-pancreatic and the digestive system—current state of the art and future perspectives

    Science.gov (United States)

    Diana, Michele; Schiraldi, Luigi; Liu, Yu-Yin; Memeo, Riccardo; Mutter, Didier; Pessaux, Patrick

    2016-01-01

    Background High intensity focused ultrasound (HIFU) is emerging as a valid minimally-invasive image-guided treatment of malignancies. We aimed to review to current state of the art of HIFU therapy applied to the digestive system and discuss some promising avenues of the technology. Methods Pertinent studies were identified through PubMed and Embase search engines using the following keywords, combined in different ways: HIFU, esophagus, stomach, liver, pancreas, gallbladder, colon, rectum, and cancer. Experimental proof of the concept of endoluminal HIFU mucosa/submucosa ablation using a custom-made transducer has been obtained in vivo in the porcine model. Results Forty-four studies reported on the clinical use of HIFU to treat liver lesions, while 19 series were found on HIFU treatment of pancreatic cancers and four studies included patients suffering from both liver and pancreatic cancers, reporting on a total of 1,682 and 823 cases for liver and pancreas, respectively. Only very limited comparative prospective studies have been reported. Conclusions Digestive system clinical applications of HIFU are limited to pancreatic and liver cancer. It is safe and well tolerated. The exact place in the hepatocellular carcinoma (HCC) management algorithm remains to be defined. HIFU seems to add clear survival advantages over trans arterial chemo embolization (TACE) alone and similar results when compared to radio frequency (RF). For pancreatic cancer, HIFU achieves consistent cancer-related pain relief. Further research is warranted to improve targeting accuracy and efficacy monitoring. Furthermore, additional work is required to transfer this technology on appealing treatments such as endoscopic HIFU-based therapies. PMID:27500145

  16. Future High Capacity Backbone Networks

    DEFF Research Database (Denmark)

    Wang, Jiayuan

    This thesis - Future High Capacity Backbone Networks - deals with the energy efficiency problems associated with the development of future optical networks. In the first half of the thesis, novel approaches for using multiple/single alternative energy sources for improving energy efficiency...... the context of the integrated control plane structure. Results show improvements of energy efficiency over three types of traffic, while still keeping acceptable QoS levels for high priority traffic....

  17. High-Intensity, High Charge-State Heavy Ion Sources

    CERN Document Server

    Alessi, J

    2004-01-01

    There are many accelerator applications for high intensity heavy ion sources, with recent needs including dc beams for RIA, and pulsed beams for injection into synchrotrons such as RHIC and LHC. The present status of sources producing high currents of high charge state heavy ions will be reviewed. These sources include ECR, EBIS, and Laser ion sources. The benefits and limitations for these type sources will be described, for both dc and pulsed applications. Possible future improvements in these type sources will also be discussed.

  18. Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 2: Intensity Frontier

    CERN Document Server

    Hewett, J L; Babu, K S; Butler, J; Casey, B; de Gouvea, A; Essig, R; Grossman, Y; Hitlin, D; Jaros, J; Kearns, E; Kumar, K; Ligeti, Z; Lu, Z -T; Pitts, K; Ramsey-Musolf, M; Ritchie, J; Scholberg, K; Wester, W; Zeller, G P

    2014-01-01

    These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 2, on the Intensity Frontier, discusses the program of research with high-intensity beams and rare processes. This area includes experiments on neutrinos, proton decay, charged-lepton and quark weak interactions, atomic and nuclear probes of fundamental symmetries, and searches for new, light, weakly-interacting particles.

  19. Probiotics in neonatal intensive care - back to the future.

    Science.gov (United States)

    Deshpande, Girish; Rao, Shripada; Patole, Sanjay

    2015-06-01

    Survival of extremely preterm and critically ill neonates has improved significantly over the last few decades following advances in neonatal intensive care. These include antenatal glucocorticoids, surfactant, continuous positive airway pressure support, advanced gentle modes of ventilation and inhaled nitric oxide. Probiotic supplementation is a recent significant milestone in the history of neonatal intensive care. Very few, if any, interventions match the ability of probiotics to significantly reduce the risk of death and definite necrotising enterocolitis while facilitating enteral feeds in high-risk preterm neonates. Probiotics also have a potential to benefit neonates with surgical conditions with significant gastrointestinal morbidity. Current evidence for the benefits of probiotic supplementation for neonates in an intensive care unit is reviewed. The mechanisms for the benefits of probiotics in this population are discussed, and guidelines for clinicians are provided in the context of the regulatory framework in Australia. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.

  20. High Intensity Secondary Beams Driven by Protons

    CERN Document Server

    Galambos, John; Nagaitsev, Sergei

    2013-01-01

    As part of the Intensity Frontier effort within the 2013 Community Summer Study, a workshop on the proton machine capabilities was held (High Intensity Secondary Beams Driven by Proton Beams) April 17-20, 2013 at Brookhaven National Laboratory in Upton, NY. Primary aims of the workshop were to understand: 1) the beam requirements for proposed high intensity proton beam based measurements; 2) the capabilities of existing world-wide high power proton machines; 3) proton facility upgrade plans and proposals for new facilities; 4) and to document the R&D needs for proton accelerators and target systems needed to support proposed intensity frontier measurements. These questions are addressed in this summary.

  1. High intensity polarized electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Sinclair, C.K.

    1980-10-01

    The status of the polarized electron source development program at SLAC will be reviewed. Emission currents of 60 A, corresponding to a space charge limited current density of 180 A/cm/sup 2/, have been obtained from GaAs photocathodes. Electron beam polarization 20% greater than that obtainable from GaAs cathodes has been observed from multilayer GaAs-GaAlAs structures. Work in progress to produce high beam polarization from II-IV-V/sub 2/ chalcopyrite photocathodes will also be described.

  2. High-Intensity Proton Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jay L. Hirshfield

    2011-12-27

    Analysis is presented for an eight-cavity proton cyclotron accelerator that could have advantages as compared with other accelerators because of its potentially high acceleration gradient. The high gradient is possible since protons orbit in a sequence of TE111 rotating mode cavities of equally diminishing frequencies with path lengths during acceleration that greatly exceed the cavity lengths. As the cavities operate at sequential harmonics of a basic repetition frequency, phase synchronism can be maintained over a relatively wide injection phase window without undue beam emittance growth. It is shown that use of radial vanes can allow cavity designs with significantly smaller radii, as compared with simple cylindrical cavities. Preliminary beam transport studies show that acceptable extraction and focusing of a proton beam after cyclic motion in this accelerator should be possible. Progress is also reported on design and tests of a four-cavity electron counterpart accelerator for experiments to study effects on beam quality arising from variations injection phase window width. This device is powered by four 500-MW pulsed amplifiers at 1500, 1800, 2100, and 2400 MHz that provide phase synchronous outputs, since they are driven from a with harmonics derived from a phase-locked 300 MHz source.

  3. High intensity neutrino oscillation facilities in Europe

    CERN Document Server

    Edgecock, T R; Davenne, T; Densham, C; Fitton, M; Kelliher, D; Loveridge, P; Machida, S; Prior, C; Rogers, C; Rooney, M; Thomason, J; Wilcox, D; Wildner, E; Efthymiopoulos, I; Garoby, R; Gilardoni, S; Hansen, C; Benedetto, E; Jensen, E; Kosmicki, A; Martini, M; Osborne, J; Prior, G; Stora, T; Melo-Mendonca, T; Vlachoudis, V; Waaijer, C; Cupial, P; Chancé, A; Longhin, A; Payet, J; Zito, M; Baussan, E; Bobeth, C; Bouquerel, E; Dracos, M; Gaudiot, G; Lepers, B; Osswald, F; Poussot, P; Vassilopoulos, N; Wurtz, J; Zeter, V; Bielski, J; Kozien, M; Lacny, L; Skoczen, B; Szybinski, B; Ustrycka, A; Wroblewski, A; Marie-Jeanne, M; Balint, P; Fourel, C; Giraud, J; Jacob, J; Lamy, T; Latrasse, L; Sortais, P; Thuillier, T; Mitrofanov, S; Loiselet, M; Keutgen, Th; Delbar, Th; Debray, F; Trophine, C; Veys, S; Daversin, C; Zorin, V; Izotov, I; Skalyga, V; Burt, G; Dexter, A C; Kravchuk, V L; Marchi, T; Cinausero, M; Gramegna, F; De Angelis, G; Prete, G; Collazuol, G; Laveder, M; Mazzocco, M; Mezzetto, M; Signorini, C; Vardaci, E; Di Nitto, A; Brondi, A; La Rana, G; Migliozzi, P; Moro, R; Palladino, V; Gelli, N; Berkovits, D; Hass, M; Hirsh, T Y; Schaumann, M; Stahl, A; Wehner, J; Bross, A; Kopp, J; Neuffer, D; Wands, R; Bayes, R; Laing, A; Soler, P; Agarwalla, S K; Villanueva, A Cervera; Donini, A; Ghosh, T; Cadenas, J J Gómez; Hernández, P; Martín-Albo, J; Mena, O; Burguet-Castell, J; Agostino, L; Buizza-Avanzini, M; Marafini, M; Patzak, T; Tonazzo, A; Duchesneau, D; Mosca, L; Bogomilov, M; Karadzhov, Y; Matev, R; Tsenov, R; Akhmedov, E; Blennow, M; Lindner, M; Schwetz, T; Martinez, E Fernández; Maltoni, M; Menéndez, J; Giunti, C; García, M C González; Salvado, J; Coloma, P; Huber, P; Li, T; López-Pavón, J; Orme, C; Pascoli, S; Meloni, D; Tang, J; Winter, W; Ohlsson, T; Zhang, H; Scotto-Lavina, L; Terranova, F; Bonesini, M; Tortora, L; Alekou, A; Aslaninejad, M; Bontoiu, C; Kurup, A; Jenner, L J; Long, K; Pasternak, J; Pozimski, J; Back, J J; Harrison, P; Beard, K; Bogacz, A; Berg, J S; Stratakis, D; Witte, H; Snopok, P; Bliss, N; Cordwell, M; Moss, A; Pattalwar, S; Apollonio, M

    2013-01-01

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the ph...

  4. High intensity neutrino oscillation facilities in Europe

    CERN Document Server

    Edgecock, T.R.; Davenne, T.; Densham, C.; Fitton, M.; Kelliher, D.; Loveridge, P.; Machida, S.; Prior, C.; Rogers, C.; Rooney, M.; Thomason, J.; Wilcox, D.; Wildner, E.; Efthymiopoulos, I.; Garoby, R.; Gilardoni, S.; Hansen, C.; Benedetto, E.; Jensen, E.; Kosmicki, A.; Martini, M.; Osborne, J.; Prior, G.; Stora, T.; Melo-Mendonca, T.; Vlachoudis, V.; Waaijer, C.; Cupial, P.; Chancé, A.; Longhin, A.; Payet, J.; Zito, M.; Baussan, E.; Bobeth, C.; Bouquerel, E.; Dracos, M.; Gaudiot, G.; Lepers, B.; Osswald, F.; Poussot, P.; Vassilopoulos, N.; Wurtz, J.; Zeter, V.; Bielski, J.; Kozien, M.; Lacny, L.; Skoczen, B.; Szybinski, B.; Ustrzycka, A.; Wroblewski, A.; Marie-Jeanne, M.; Balint, P.; Fourel, C.; Giraud, J.; Jacob, J.; Lamy, T.; Latrasse, L.; Sortais, P.; Thuillier, T.; Mitrofanov, S.; Loiselet, M.; Keutgen, Th.; Delbar, Th.; Debray, F.; Trophine, C.; Veys, S.; Daversin, C.; Zorin, V.; Izotov, I.; Skalyga, V.; Burt, G.; Dexter, A.C.; Kravchuk, V.L.; Marchi, T.; Cinausero, M.; Gramegna, F.; De Angelis, G.; Prete, G.; Collazuol, G.; Laveder, M.; Mazzocco, M.; Mezzetto, M.; Signorini, C.; Vardaci, E.; Di Nitto, A.; Brondi, A.; La Rana, G.; Migliozzi, P.; Moro, R.; Palladino, V.; Gelli, N.; Berkovits, D.; Hass, M.; Hirsh, T.Y.; Schaumann, M.; Stahl, A.; Wehner, J.; Bross, A.; Kopp, J.; Neuffer, D.; Wands, R.; Bayes, R.; Laing, A.; Soler, P.; Agarwalla, S.K.; Cervera Villanueva, A.; Donini, A.; Ghosh, T.; Gómez Cadenas, J.J.; Hernández, P.; Martín-Albo, J.; Mena, O.; Burguet-Castell, J.; Agostino, L.; Buizza-Avanzini, M.; Marafini, M.; Patzak, T.; Tonazzo, A.; Duchesneau, D.; Mosca, L.; Bogomilov, M.; Karadzhov, Y.; Matev, R.; Tsenov, R.; Akhmedov, E.; Blennow, M.; Lindner, M.; Schwetz, T.; Fernández Martinez, E.; Maltoni, M.; Menéndez, J.; Giunti, C.; González García, M. C.; Salvado, J.; Coloma, P.; Huber, P.; Li, T.; López-Pavón, J.; Orme, C.; Pascoli, S.; Meloni, D.; Tang, J.; Winter, W.; Ohlsson, T.; Zhang, H.; Scotto-Lavina, L.; Terranova, F.; Bonesini, M.; Tortora, L.; Alekou, A.; Aslaninejad, M.; Bontoiu, C.; Kurup, A.; Jenner, L.J.; Long, K.; Pasternak, J.; Pozimski, J.; Back, J.J.; Harrison, P.; Beard, K.; Bogacz, A.; Berg, J.S.; Stratakis, D.; Witte, H.; Snopok, P.; Bliss, N.; Cordwell, M.; Moss, A.; Pattalwar, S.; Apollonio, M.

    2013-02-20

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the ph...

  5. High intensity neutrino oscillation facilities in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Edgecock, T. R.; Caretta, O.; Davenne, T.; Densam, C.; Fitton, M.; Kelliher, D.; Loveridge, P.; Machida, S.; Prior, C.; Rogers, C.; Rooney, M.; Thomason, J.; Wilcox, D.; Wildner, E.; Efthymiopoulos, I.; Garoby, R.; Gilardoni, S.; Hansen, C.; Benedetto, E.; Jensen, E.; Kosmicki, A.; Martini, M.; Osborne, J.; Prior, G.; Stora, T.; Melo Mendonca, T.; Vlachoudis, V.; Waaijer, C.; Cupial, P.; Chancé, A.; Longhin, A.; Payet, J.; Zito, M.; Baussan, E.; Bobeth, C.; Bouquerel, E.; Dracos, M.; Gaudiot, G.; Lepers, B.; Osswald, F.; Poussot, P.; Vassilopoulos, N.; Wurtz, J.; Zeter, V.; Bielski, J.; Kozien, M.; Lacny, L.; Skoczen, B.; Szybinski, B.; Ustrycka, A.; Wroblewski, A.; Marie-Jeanne, M.; Balint, P.; Fourel, C.; Giraud, J.; Jacob, J.; Lamy, T.; Latrasse, L.; Sortais, P.; Thuillier, T.; Mitrofanov, S.; Loiselet, M.; Keutgen, Th.; Delbar, Th.; Debray, F.; Trophine, C.; Veys, S.; Daversin, C.; Zorin, V.; Izotov, I.; Skalyga, V.; Burt, G.; Dexter, A. C.; Kravchuk, V. L.; Marchi, T.; Cinausero, M.; Gramegna, F.; De Angelis, G.; Prete, G.; Collazuol, G.; Laveder, M.; Mazzocco, M.; Mezzetto, M.; Signorini, C.; Vardaci, E.; Di Nitto, A.; Brondi, A.; La Rana, G.; Migliozzi, P.; Moro, R.; Palladino, V.; Gelli, N.; Berkovits, D.; Hass, M.; Hirsh, T. Y.; Schaumann, M.; Stahl, A.; Wehner, J.; Bross, A.; Kopp, J.; Neuffer, D.; Wands, R.; Bayes, R.; Laing, A.; Soler, P.; Agarwalla, S. K.; Cervera Villanueva, A.; Donini, A.; Ghosh, T.; Gómez Cadenas, J. J.; Hernández, P.; Martín-Albo, J.; Mena, O.; Burguet-Castell, J.; Agostino, L.; Buizza-Avanzini, M.; Marafini, M.; Patzak, T.; Tonazzo, A.; Duchesneau, D.; Mosca, L.; Bogomilov, M.; Karadzhov, Y.; Matev, R.; Tsenov, R.; Akhmedov, E.; Blennow, M.; Lindner, M.; Schwetz, T.; Fernández Martinez, E.; Maltoni, M.; Menéndez, J.; Giunti, C.; González García, M. C.; Salvado, J.; Coloma, P.; Huber, P.; Li, T.; López Pavón, J.; Orme, C.; Pascoli, S.; Meloni, D.; Tang, J.; Winter, W.; Ohlsson, T.; Zhang, H.; Scotto-Lavina, L.; Terranova, F.; Bonesini, M.; Tortora, L.; Alekou, A.; Aslaninejad, M.; Bontoiu, C.; Kurup, A.; Jenner, L. J.; Long, K.; Pasternak, J.; Pozimski, J.; Back, J. J.; Harrison, P.; Beard, K.; Bogacz, A.; Berg, J. S.; Stratakis, D.; Witte, H.; Snopok, P.; Bliss, N.; Cordwell, M.; Moss, A.; Pattalwar, S.; Apollonio, M.

    2013-02-01

    The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fr\\'ejus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of {\\mu}+ and {\\mu}- beams in a storage ring. The far detector in this case is a 100 kt Magnetised Iron Neutrino Detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular 6He and 18Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fr\\'ejus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.

  6. High Intensity Interval Training: New Insights

    Institute of Scientific and Technical Information of China (English)

    Martin J.Gibala

    2008-01-01

    @@ KEY POINTS ·High-intensity interval training(HIT)is characterized by repeated sessions of relatively brief,intermittent exercise.often performed with an“a11 out”effort or at an intensity close to that which elicits peak oxygen uptake(i.e.,≥90%of VO2 peak).

  7. High Intensity Exercise in Multiple Sclerosis

    DEFF Research Database (Denmark)

    Wens, Inez; Dalgas, Ulrik; Vandenabeele, Frank

    2015-01-01

    Introduction Low-to-moderate intensity exercise improves muscle contractile properties and endurance capacity in multiple sclerosis (MS). The impact of high intensity exercise remains unknown. Methods Thirty-four MS patients were randomized into a sedentary control group (SED, n = 11) and 2...

  8. High-intensity training in football.

    Science.gov (United States)

    Iaia, F Marcello; Rampinini, Ermanno; Bangsbo, Jens

    2009-09-01

    This article reviews the major physiological and performance effects of aerobic high-intensity and speed-endurance training in football, and provides insight on implementation of individual game-related physical training. Analysis and physiological measurements have revealed that modern football is highly energetically demanding, and the ability to perform repeated high-intensity work is of importance for the players. Furthermore, the most successful teams perform more high-intensity activities during a game when in possession of the ball. Hence, footballers need a high fitness level to cope with the physical demands of the game. Studies on football players have shown that 8 to 12 wk of aerobic high-intensity running training (> 85% HR(max)) leads to VO2(max) enhancement (5% to 11%), increased running economy (3% to 7%), and lower blood lactate accumulation during submaximal exercise, as well as improvements in the yo-yo intermittent recovery (YYIR) test performance (13%). Similar adaptations are observed when performing aerobic high-intensity training with small-sided games. Speed-endurance training has a positive effect on football-specific endurance, as shown by the marked improvements in the YYIR test (22% to 28%) and the ability to perform repeated sprints (approximately 2%). In conclusion, both aerobic and speed-endurance training can be used during the season to improve high-intensity intermittent exercise performance. The type and amount of training should be game related and specific to the technical, tactical, and physical demands imposed on each player.

  9. High intensity neutrino oscillation facilities in Europe

    Directory of Open Access Journals (Sweden)

    T. R. Edgecock

    2013-02-01

    Full Text Available The EUROnu project has studied three possible options for future, high intensity neutrino oscillation facilities in Europe. The first is a Super Beam, in which the neutrinos come from the decay of pions created by bombarding targets with a 4 MW proton beam from the CERN High Power Superconducting Proton Linac. The far detector for this facility is the 500 kt MEMPHYS water Cherenkov, located in the Fréjus tunnel. The second facility is the Neutrino Factory, in which the neutrinos come from the decay of μ^{+} and μ^{-} beams in a storage ring. The far detector in this case is a 100 kt magnetized iron neutrino detector at a baseline of 2000 km. The third option is a Beta Beam, in which the neutrinos come from the decay of beta emitting isotopes, in particular ^{6}He and ^{18}Ne, also stored in a ring. The far detector is also the MEMPHYS detector in the Fréjus tunnel. EUROnu has undertaken conceptual designs of these facilities and studied the performance of the detectors. Based on this, it has determined the physics reach of each facility, in particular for the measurement of CP violation in the lepton sector, and estimated the cost of construction. These have demonstrated that the best facility to build is the Neutrino Factory. However, if a powerful proton driver is constructed for another purpose or if the MEMPHYS detector is built for astroparticle physics, the Super Beam also becomes very attractive.

  10. Photoproduction at High Energy and High Intensity

    CERN Multimedia

    2002-01-01

    The photon beam used for this programme is tagged and provides a large flux up to very high energies (150-200 GeV). It is also hadron-free, since it is obtained by a two-step conversion method. A spectrometer is designed to exploit this beam and to perform a programme of photoproduction with a high level of sensitivity (5-50 events/picobarn).\\\\ \\\\ Priority will be given to the study of processes exhibiting the point-like behaviour of the photon, especially deep inelastic Compton scattering. The spectrometer has two magnets. Charged tracks are measured by MWPC's located only in field-free regions. Three calorimeters provide a large coverage for identifying and measuring electrons and photons. An iron filter downstream identifies muons. Most of the equipment is existing and recuperated from previous experiments.

  11. Towards optical intensity interferometry for high angular resolution stellar astrophysics

    CERN Document Server

    Nunez, Paul D

    2012-01-01

    Most neighboring stars are still detected as point sources and are beyond the angular resolution reach of current observatories. Methods to improve our understanding of stars at high angular resolution are investigated. Air Cherenkov telescopes (ACTs), primarily used for Gamma-ray astronomy, enable us to increase our understanding of the circumstellar environment of a particular system. When used as optical intensity interferometers, future ACT arrays will allow us to detect stars as extended objects and image their surfaces at high angular resolution. Optical stellar intensity interferometry (SII) with ACT arrays, composed of nearly 100 telescopes, will provide means to measure fundamental stellar parameters and also open the possibility of model-independent imaging. A data analysis algorithm is developed and permits the reconstruction of high angular resolution images from simulated SII data. The capabilities and limitations of future ACT arrays used for high angular resolution imaging are investigated via ...

  12. Intensity changes in future extreme precipitation: A statistical event-based approach.

    Science.gov (United States)

    Manola, Iris; van den Hurk, Bart; de Moel, Hans; Aerts, Jeroen

    2017-04-01

    Short-lived precipitation extremes are often responsible for hazards in urban and rural environments with economic and environmental consequences. The precipitation intensity is expected to increase about 7% per degree of warming, according to the Clausius-Clapeyron (CC) relation. However, the observations often show a much stronger increase in the sub-daily values. In particular, the behavior of the hourly summer precipitation from radar observations with the dew point temperature (the Pi-Td relation) for the Netherlands suggests that for moderate to warm days the intensification of the precipitation can be even higher than 21% per degree of warming, that is 3 times higher than the expected CC relation. The rate of change depends on the initial precipitation intensity, as low percentiles increase with a rate below CC, the medium percentiles with 2CC and the moderate-high and high percentiles with 3CC. This non-linear statistical Pi-Td relation is suggested to be used as a delta-transformation to project how a historic extreme precipitation event would intensify under future, warmer conditions. Here, the Pi-Td relation is applied over a selected historic extreme precipitation event to 'up-scale' its intensity to warmer conditions. Additionally, the selected historic event is simulated in the high-resolution, convective-permitting weather model Harmonie. The initial and boundary conditions are alternated to represent future conditions. The comparison between the statistical and the numerical method of projecting the historic event to future conditions showed comparable intensity changes, which depending on the initial percentile intensity, range from below CC to a 3CC rate of change per degree of warming. The model tends to overestimate the future intensities for the low- and the very high percentiles and the clouds are somewhat displaced, due to small wind and convection changes. The total spatial cloud coverage in the model remains, as also in the statistical

  13. Stimulated Raman backscattering at high laser intensities

    Energy Technology Data Exchange (ETDEWEB)

    Skoric, M.M. [Vinca Inst. of Nuclear Sciences, Belgrade (Yugoslavia); Tajima, Toshiki; Sasaki, Akira; Maluckov, A.; Jovanovic, M.

    1998-03-01

    Signatures of Stimulated Raman backscattering of a short-pulse high-intensity laser interacting with an underdense plasma are discussed. We introduce a nonlinear three-wave interaction model that accounts for laser pump depletion and relativistic detuning. A mechanism is revealed based on a generic route to chaos, that predicts a progressive increase of the backscatter complexity with a growing laser intensity. Importance of kinetic effects is outlined and demonstrated in fluid-hybrid and particle simulations. As an application, we show that spectral anomalies of the backscatter, predicted by the above model, are consistent with recent sub-picosecond, high-intensity laser gas-target measurements at Livermore and elsewhere. Finally, a recently proposed scheme for generation of ultra-short, low-prepulse laser pulses by Raman backscattering in a thin foil target, is shown. (author)

  14. The intense neutron generator and future factory type ion accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, W.B

    1968-07-01

    A neutron factory is likely to sell its product in the form of isotopes. To ay neutron factories are nuclear reactors. Ion accelerators may also produce isotopes by direct interaction and, at high enough energies, mesons and hyperons. The challenge of the electrical production of neutrons goes far beyond the isotope market. It challenges the two popular concepts for long term large scale energy, the fast breeder reactor and controlled thermonuclear fusion. For this use about 4% of nuclear generated power would be applied in a feedback loop generating extra neutrons. Competition rests on operating and processing costs. The Intense Neutron Generator proposal now cancelled would have been full scale for such a use, but much further advance in accelerator engineering is required and anticipated. Perhaps most promising is the application of the ion drag principle in which rings of fast electrons are accelerated along their axis dragging ions with them by electrostatic attraction. Due to the much larger mass of the ions they can acquire much higher energy than the electrons and the process could be efficient. Such accelerators have not yet been made but experimental and theoretical studies are promising. (author)

  15. High-intensity, focused ultrasonic fields

    DEFF Research Database (Denmark)

    Jensen, Leif Bjørnø

    1988-01-01

    distribution, etc. involving nonlinearity, diffraction, and absorption in the high-intensity focused ultrasonic fields produced by an ellipsoid as well as a spherical cap focusing geometry. Data from the development of an ESWL of the piezoelectric disk type are reported including demands to transducers...

  16. Cryogenic semiconductor high-intensity radiation monitors

    CERN Document Server

    Palmieri, V G; Borer, K; Casagrande, L; Da Vià, C; Devine, S R H; Dezillie, B; Esposito, A; Granata, V; Hauler, F; Jungermann, L; Li, Z; Lourenço, C; Niinikoski, T O; O'Shea, V

    2003-01-01

    This paper describes a novel technique to monitor high-intensity particle beams by means of a semiconductor detector. It consists of cooling a semiconductor detector down to cryogenic temperature to suppress the thermally generated leakage current and to precisely measure the integrated ionization signal. It will be shown that such a device provides very good linearity and a dynamic range wider than is possible with existing techniques. Moreover, thanks to the Lazarus effect, extreme radiation hardness can be achieved providing in turn absolute intensity measurements against precise calibration of the device at low beam flux.

  17. High-Intensity Focused Ultrasound Therapy: an Overview for Radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Sun; Rhim, Hyun Chul; Lim, Hyo Keun; Choi, Dong Il [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choi, Min Joo [College of Medicine, Cheju National University, Jeju (Korea, Republic of)

    2008-08-15

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments

  18. High-intensity focused ultrasound therapy: an overview for radiologists.

    Science.gov (United States)

    Kim, Young-sun; Rhim, Hyunchul; Choi, Min Joo; Lim, Hyo Keun; Choi, Dongil

    2008-01-01

    High-intensity focused ultrasound therapy is a novel, emerging, therapeutic modality that uses ultrasound waves, propagated through tissue media, as carriers of energy. This completely non-invasive technology has great potential for tumor ablation as well as hemostasis, thrombolysis and targeted drug/gene delivery. However, the application of this technology still has many drawbacks. It is expected that current obstacles to implementation will be resolved in the near future. In this review, we provide an overview of high-intensity focused ultrasound therapy from the basic physics to recent clinical studies with an interventional radiologist's perspective for the purpose of improving the general understanding of this cutting-edge technology as well as speculating on future developments.

  19. Concept for a new high resolution high intensity diffractometer

    Energy Technology Data Exchange (ETDEWEB)

    Stuhr, U. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-09-01

    A concept of a new time-of-flight powder-diffractometer for a thermal neutral beam tube at SINQ is presented. The design of the instrument optimises the contradictory conditions of high intensity and high resolution. The high intensity is achieved by using many neutron pulses simultaneously. By analysing the time-angle-pattern of the detected neutrons an assignment of the neutrons to a single pulse is possible. (author) 3 figs., tab., refs.

  20. The high intensity neutron source FRANZ

    CERN Document Server

    Lederer, Claudia

    2014-01-01

    The Frankfurt neutron source of Stern Gerlach Zentrum FRANZ is currently under construction at the University of Frankfurt. At FRANZ, a high intensity neutron beam in the keV energy region will be produced by bombarding a $^7$Li target with a proton beam of several mA. These unprecedented high neutron fluxes will allow a number of neutron induced cross section measurements for the first time. Measurements can be performed by the time-of-flight and by the activation technique.

  1. High intensity specular reflectometry - first experiments

    CERN Document Server

    Stahn, J; Panzner, T

    2011-01-01

    Selene is the attempt to implement a new scheme for high-intensity specular reflectometry. Instead of a highly collimated beam one uses a convergent beam covering a large angular range. The angular resolution is then performed by a position-sensitive detector. Off-specular scattering in this set-up leads to some background, but for screening of wide parameter ranges (e.g. temperature, electric and magnetic fields) the intensity gain of at least one order of magnitude is essential. If necessary, the high precession measurements (even with off-specular components) then are performed with the conventional set-up. The heart of this new set-up is an elliptically focusing guide element of 2\\,m length. Though this guide is optimised for the use on the TOF reflectometer Amor at SINQ, it can be used as stand-alone device to check the possible application also for other neutron scattering techniques. The first measurements on AMOR confirmed the general concept and the various operation modes. A draw-back occurred due t...

  2. High Intensity Beam Issues in the CERN Proton Synchrotron

    CERN Document Server

    Aumon, Sandra; Rivkin, Leonid

    This PhD work is about limitations of high intensity proton beams observed in the CERN Proton Synchrotron (PS) and, in particular, about issues at injection and transition energies. With its 53 years, the CERN PS would have to operate beyond the limit of its performance to match the future requirements. Beam instabilities driven by transverse impedance and aperture restrictions are important issues for the operation and for the High-Luminosity LHC upgrade which foresees an intensity increase delivered by the injectors. The main subject of the thesis concerns the study of a fast transverse instability occurring at transition energy. The proton beams crossing this energy range are particularly sensitive to wake forces because of the slow synchrotron motion. This instability can cause a strong vertical emittance blow-up and severe losses in less than a synchrotron period. Experimental observations show that the particles at the peak density of the beam longitudinal distribution oscillate in the vertical plane du...

  3. Dynamic Jump Intensities and Risk Premiums in Crude Oil Futures and Options Markets

    DEFF Research Database (Denmark)

    Christoffersen, Peter; Jacobs, Kris; Li, Bingxin

    2016-01-01

    and dynamic jump intensities in these markets. Allowing for jumps is crucial for modeling crude oil futures and futures options, and we find evidence in favor of time-varying jump intensities. During crisis periods, jumps occur more frequently. The properties of the jump processes implied by the option data......Options on crude oil futures are the most actively traded commodity options. We develop a class of computationally efficient discrete-time jump models that allow for closed-form option valuation, and we use crude oil futures and options data to investigate the economic importance of jumps...

  4. High Intensity High Charge State ECR Ion Sources

    CERN Document Server

    Leitner, Daniela

    2005-01-01

    The next-generation heavy ion beam accelerators such as the proposed Rare Isotope Accelerator (RIA), the Radioactive Ion Beam Factory at RIKEN, the GSI upgrade project, the LHC-upgrade, and IMP in Lanzhou require a great variety of high charge state ion beams with a magnitude higher beam intensity than currently achievable. High performance Electron Cyclotron Resonance (ECR) ion sources can provide the flexibility since they can routinely produce beams from hydrogen to uranium. Over the last three decades, ECR ion sources have continued improving the available ion beam intensities by increasing the magnetic fields and ECR heating frequencies to enhance the confinement and the plasma density. With advances in superconducting magnet technology, a new generation of high field superconducting sources is now emerging, designed to meet the requirements of these next generation accelerator projects. The talk will briefly review the field of high performance ECR ion sources and the latest developments for high intens...

  5. High-intensity sweeteners and energy balance.

    Science.gov (United States)

    Swithers, Susan E; Martin, Ashley A; Davidson, Terry L

    2010-04-26

    Recent epidemiological evidence points to a link between a variety of negative health outcomes (e.g. metabolic syndrome, diabetes and cardiovascular disease) and the consumption of both calorically sweetened beverages and beverages sweetened with high-intensity, non-caloric sweeteners. Research on the possibility that non-nutritive sweeteners promote food intake, body weight gain, and metabolic disorders has been hindered by the lack of a physiologically-relevant model that describes the mechanistic basis for these outcomes. We have suggested that based on Pavlovian conditioning principles, consumption of non-nutritive sweeteners could result in sweet tastes no longer serving as consistent predictors of nutritive postingestive consequences. This dissociation between the sweet taste cues and the caloric consequences could lead to a decrease in the ability of sweet tastes to evoke physiological responses that serve to regulate energy balance. Using a rodent model, we have found that intake of foods or fluids containing non-nutritive sweeteners was accompanied by increased food intake, body weight gain, accumulation of body fat, and weaker caloric compensation, compared to consumption of foods and fluids containing glucose. Our research also provided evidence consistent with the hypothesis that these effects of consuming saccharin may be associated with a decrement in the ability of sweet taste to evoke thermic responses, and perhaps other physiological, cephalic phase, reflexes that are thought to help maintain energy balance.

  6. Physics of intense, high energy radiation effects.

    Energy Technology Data Exchange (ETDEWEB)

    Hjalmarson, Harold Paul; Hartman, E. Frederick; Magyar, Rudolph J.; Crozier, Paul Stewart

    2011-02-01

    This document summarizes the work done in our three-year LDRD project titled 'Physics of Intense, High Energy Radiation Effects.' This LDRD is focused on electrical effects of ionizing radiation at high dose-rates. One major thrust throughout the project has been the radiation-induced conductivity (RIC) produced by the ionizing radiation. Another important consideration has been the electrical effect of dose-enhanced radiation. This transient effect can produce an electromagnetic pulse (EMP). The unifying theme of the project has been the dielectric function. This quantity contains much of the physics covered in this project. For example, the work on transient electrical effects in radiation-induced conductivity (RIC) has been a key focus for the work on the EMP effects. This physics in contained in the dielectric function, which can also be expressed as a conductivity. The transient defects created during a radiation event are also contained, in principle. The energy loss lead the hot electrons and holes is given by the stopping power of ionizing radiation. This information is given by the inverse dielectric function. Finally, the short time atomistic phenomena caused by ionizing radiation can also be considered to be contained within the dielectric function. During the LDRD, meetings about the work were held every week. These discussions involved theorists, experimentalists and engineers. These discussions branched out into the work done in other projects. For example, the work on EMP effects had influence on another project focused on such phenomena in gases. Furthermore, the physics of radiation detectors and radiation dosimeters was often discussed, and these discussions had impact on related projects. Some LDRD-related documents are now stored on a sharepoint site (https://sharepoint.sandia.gov/sites/LDRD-REMS/default.aspx). In the remainder of this document the work is described in catergories but there is much overlap between the atomistic

  7. The infant incubator in the neonatal intensive care unit: unresolved issues and future developments.

    Science.gov (United States)

    Antonucci, Roberto; Porcella, Annalisa; Fanos, Vassilios

    2009-01-01

    Since the 19th century, devices termed incubators were developed to maintain thermal stability in low birth weight (LBW) and sick newborns, thus improving their chances of survival. Remarkable progress has been made in the production of infant incubators, which are currently highly technological devices. However, they still need to be improved in many aspects. Regarding the temperature and humidity control, future incubators should minimize heat loss from the neonate and eddies around him/her. An unresolved issue is exposure to high noise levels in the Neonatal Intensive Care Unit (NICU). Strategies aimed at modifying the behavior of NICU personnel, along with structural improvements in incubator design, are required to reduce noise exposure. Light environment should be taken into consideration in designing new models of incubators. In fact, ambient NICU illumination may cause visual pathway sequelae or possibly retinopathy of prematurity (ROP), while premature exposure to continuous lighting may adversely affect the rest-activity patterns of the newborn. Accordingly, both the use of incubator covers and circadian lighting in the NICU might attenuate these effects. The impact of electromagnetic fields (EMFs) on infant health is still unclear. However, future incubators should be designed to minimize the EMF exposure of the newborn.

  8. Future high energy colliders symposium. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    Parsa, Z. [Univ. of California, Santa Barbara, CA (United States). Institute for Theoretical Physics]|[Brookhaven National Lab., Upton, CA (United States)

    1996-12-31

    A `Future High Energy Colliders` Symposium was held October 21-25, 1996 at the Institute for Theoretical Physics (ITP) in Santa Barbara. This was one of the 3 symposia hosted by the ITP and supported by its sponsor, the National Science Foundation, as part of a 5 month program on `New Ideas for Particle Accelerators`. The long term program and symposia were organized and coordinated by Dr. Zohreh Parsa of Brookhaven National Laboratory/ITP. The purpose of the symposium was to discuss the future direction of high energy physics by bringing together leaders from the theoretical, experimental and accelerator physics communities. Their talks provided personal perspectives on the physics objectives and the technology demands of future high energy colliders. Collectively, they formed a vision for where the field should be heading and how it might best reach its objectives.

  9. Muscle fatigue during high-intensity exercise in children.

    Science.gov (United States)

    Ratel, Sébastien; Duché, Pascale; Williams, Craig A

    2006-01-01

    Children are able to resist fatigue better than adults during one or several repeated high-intensity exercise bouts. This finding has been reported by measuring mechanical force or power output profiles during sustained isometric maximal contractions or repeated bouts of high-intensity dynamic exercises. The ability of children to better maintain performance during repeated high-intensity exercise bouts could be related to their lower level of fatigue during exercise and/or faster recovery following exercise. This may be explained by muscle characteristics of children, which are quantitatively and qualitatively different to those of adults. Children have less muscle mass than adults and hence, generate lower absolute power during high-intensity exercise. Some researchers also showed that children were equipped better for oxidative than glycolytic pathways during exercise, which would lead to a lower accumulation of muscle by-products. Furthermore, some reports indicated that the lower ability of children to activate their type II muscle fibres would also explain their greater resistance to fatigue during sustained maximal contractions. The lower accumulation of muscle by-products observed in children may be suggestive of a reduced metabolic signal, which induces lower ratings of perceived exertion. Factors such as faster phosphocreatine resynthesis, greater oxidative capacity, better acid-base regulation, faster readjustment of initial cardiorespiratory parameters and higher removal of metabolic by-products in children could also explain their faster recovery following high-intensity exercise.From a clinical point of view, muscle fatigue profiles are different between healthy children and children with muscle and metabolic diseases. Studies of dystrophic muscles in children indicated contradictory findings of changes in contractile properties and the muscle fatigability. Some have found that the muscle of boys with Duchenne muscular dystrophy (DMD) fatigued less

  10. High-Intensity Synchrotron Radiation Effects

    CERN Document Server

    Suetsugu, Y

    2016-01-01

    Various effects of intense synchrotron radiation on the performance of particle accelerators, especially for storage rings, are discussed. Following a brief introduction to synchrotron radiation, the basic concepts of heat load, gas load, electron emission, and the countermeasures against these effects are discussed.

  11. Development of High Intensity Beam Emittance Measurement Unit

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Three sets of High Intensity Beam Emittance Measurement Units (HIBEMUs) are being developed at Peking University. They are HIBEMU-2 (slit-wire type, one direction), HIBEMU-3 (Allison scanner type, one direction) and HIBEMU-4 (slit-wire type, two directions). For HIBEMU-2 and HIBEMU-3, more recent work has been done on software redesign in order to measure beam emittance and to draw phase diagram more efficiently and precisely. Software for control and data processing of them were developed in Labveiw environment, trying to improve calculation rationality and to offer user-friendly interface. Mechanical modification was also done for HIBEMU-3, mainly concentrating on the protection of Faraday cups from being overheated by the high intensity beam and also from interference of secondary electrons. This paper will also cover the mechanical structure as well as the software development of HIBEMU-4, which is a two-direction emittance scanner newly designed and manufactured for the high energy beam transport (HEBT) of Peking University Neutron Imaging FaciliTY (PKUNIFTY). At the end of this paper, comparison and analysis of the three HIBEMUs are given to draw forth better design of the future emittance measurement facility.

  12. The future of high resolution electron microscopy

    Institute of Scientific and Technical Information of China (English)

    D Van Dyck

    2000-01-01

    The state of the art and the future in quantitative high resolution electron microscopy are discussed in the framework of parameter estimation. Reconstruction methods are then to be considered as direct methods to yield a starting structure for further refinement. With the increasing flexibility of the instruments, computer aided experimental strategy will become important.

  13. Future of high energy physics some aspects

    CERN Document Server

    Prokofiev, Kirill

    2017-01-01

    This book comprises 26 carefully edited articles with well-referenced and up-to-date material written by many of the leading experts. These articles originated from presentations and dialogues at the second HKUST Institute for Advanced Study Program on High Energy Physics are organized into three aspects, Theory, Accelerator, and Experiment, focusing on in-depth analyses and technical aspects that are essential for the developments and expectations for the future high energy physics.

  14. Stretching Effects: High-intensity & Moderate-duration vs. Low-intensity & Long-duration.

    Science.gov (United States)

    Freitas, S R; Vaz, J R; Bruno, P M; Andrade, R; Mil-Homens, P

    2016-03-01

    This study examined whether a high-intensity, moderate-duration bout of stretching would produce the same acute effects as a low-intensity, long-duration bout of stretching. 17 volunteers performed 2 knee-flexor stretching protocols: a high-intensity stretch (i. e., 100% of maximum tolerable passive torque) with a moderate duration (243.5 ± 69.5-s); and a low-intensity stretch (50% of tolerable passive torque) with a long duration (900-s). Passive torque at a given sub-maximal angle, peak passive torque, maximal range of motion (ROM), and muscle activity were assessed before and after each stretching protocol (at intervals of 1, 30 and 60 min). The maximal ROM and tolerable passive torque increased for all time points following the high-intensity stretching (p0.05). 1 min post-stretching, the passive torque decreased in both protocols, but to a greater extent in the low-intensity protocol. 30 min post-test, torque returned to baseline for the low-intensity protocol and had increased above the baseline for the high-intensity stretches. The following can be concluded: 1) High-intensity stretching increases the maximal ROM and peak passive torque compared to low-intensity stretching; 2) low-intensity, long-duration stretching is the best way to acutely decrease passive torque; and 3) high-intensity, moderate-duration stretching increases passive torque above the baseline 30 min after stretching. © Georg Thieme Verlag KG Stuttgart · New York.

  15. On the Future High Energy Colliders

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, Vladimir [Fermilab

    2015-09-28

    High energy particle colliders have been in the forefront of particle physics for more than three decades. At present the near term US, European and international strategies of the particle physics community are centered on full exploitation of the physics potential of the Large Hadron Collider (LHC) through its high-luminosity upgrade (HL-LHC). A number of the next generation collider facilities have been proposed and are currently under consideration for the medium and far-future of accelerator-based high energy physics. In this paper we offer a uniform approach to evaluation of various accelerators based on the feasibility of their energy reach, performance potential and cost range.

  16. Is high-intensity exercise better than moderate-intensity exercise for weight loss?

    Science.gov (United States)

    De Feo, P

    2013-11-01

    This viewpoint debates the state-of-the-art research focusing on the optimal intensity of the exercise programs for inducing a sustained weight or fat-mass loss in overweight/obese people. In our demanding society, the most attractive messages in the popular press are those promising the best results in a short time. This might explain the emphasis given by media to those scientific articles that report the efficacy on weight loss of exercise programs by their shorter duration and higher intensity. However, in the literature on overweight or obese people, there is little conclusive evidence for more favorable effects with high-intensity training than with continuous moderate-intensity exercise on body weight or fat mass loss. Since both exercise protocols have been demonstrated as useful to reduce body weight, the decision on the intensity of exercise prescription should be individualized and based on outcomes different from fat or weight loss. In this regard, there are pro and contra arguments for the prescription of high-intensity aerobic exercise in obese people. Among the pro arguments, is the demonstration that, in several studies, high-intensity training appears to induce superior improvements in aerobic fitness. Among the contra arguments to prescribe high-intensity exercise is the demonstration that prescribing a higher-intensity exercise decreases adherence and results in the completion of less exercise. Thus, a successful exercise program should be proposed at a moderate intensity and a low perceived effort because obese subjects who have low self-efficacy, poor mood status, and are not familiar with high-intensity workouts could easily drop out. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Past and future trends of hydroclimatic intensity over the Indian monsoon region

    Science.gov (United States)

    Mohan, T. S.; Rajeevan, M.

    2017-01-01

    The hydroclimatic intensity index (HY-INT) is a single index that quantitatively combines measures of precipitation intensity and dry spell length, thus providing an integrated response of the hydrological cycle to global warming. The HY-INT index is a product of the precipitation intensity (PINT, intensity during wet days) and dry spell length (DSL). Using the observed gridded rainfall data sets of 1951-2010 period, the changes in HY-INT, PINT, and DSL over the Indian monsoon region have been examined in addition to changes in maximum consecutive dry days (MCD). We have also considered 10 Coupled Model Intercomparison Project Phase 5 (CMIP5) climate models for examining the changes in these indices during the present-day and future climate change scenarios. For climate change projections, the Representative Concentration Pathway (RCP) 4.5 scenario was considered. The analysis of observational data during the period 1951-2010 suggested an increase in DSL and MCD over most of central India. Further, statistically significant (95% level) increase in HY-INT is also noted during the period of 1951-2010, which is mainly caused due to significant increase in precipitation intensity. The CMIP5 model projections of future climate also suggest a statistically significant increase in HY-INT over the Indian region. Out of the 10 models considered, seven models suggest a consistent increase in HY-INT during the period of 2010-2100 under the RCP4.5 scenario. However, the projected increase in HY-INT is mainly due to increase in the precipitation intensity, while dry spell length (DSL) showed little changes in the future climate.

  18. Outcomes of exertional rhabdomyolysis following high-intensity resistance training.

    Science.gov (United States)

    Huynh, A; Leong, K; Jones, N; Crump, N; Russell, D; Anderson, M; Steinfort, D; Johnson, D F

    2016-05-01

    High-intensity resistance training (HIRT) programmes are increasingly popular amongst personal trainers and those attending gymnasiums. We report the experience of exertional rhabdomyolysis (ER) at two tertiary hospitals in Melbourne, Australia. To compare the clinical outcomes of ER with other causes of rhabdomyolysis. Retrospective cross-sectional study of patients presenting with a serum creatine kinase (CK) of greater than 25 000 units/L from 1 September 2013 to 31 August 2014 at two tertiary referral hospitals in Melbourne, Australia. Records were examined to identify care measures implemented during hospital stay, clinical outcomes during admission and on subsequent follow up. Thirty four cases of rhabdomyolysis with a CK of greater than 25 000 units/L (normal range: 20-180 units/L) were identified during the 12-month study period. Twelve of the 34 cases (35%) had ER with 10 of 12 related to HIRT. No acute kidney injury, intensive care admission or death were seen among those with ER. All cases were managed conservatively, with 11 admitted and 9 receiving intravenous fluids only. In contrast, patients with rhabdomyolysis from other causes experienced significantly higher rates of intensive care admission (64%, P = 0.0002), acute kidney injury (82%, P = 0.0001) and death (27%, P = 0.069). ER resulting from HIRT appears to have a benign course compared with rhabdomyolysis of other aetiologies in patients with a serum CK greater than 25 000 units/L. Conservative management of ER appears to be adequate, although this requires confirmation in future prospective studies. © 2016 Royal Australasian College of Physicians.

  19. High performance computation on beam dynamics problems in high intensity compact cyclotrons

    Institute of Scientific and Technical Information of China (English)

    ADELMANN; Andreas

    2011-01-01

    This paper presents the research progress in the beam dynamics problems for future high intensity compact cyclotrons by utilizing the state-of-the-art high performance computation technology. A "Start-to-Stop" model, which includes both the interaction of the internal particles of a single bunch and the mutual interaction of neighboring multiple bunches in the radial direction, is established for compact cyclotrons with multi-turn extraction. This model is then implemented in OPAL-CYCL, which is a 3D object-oriented parallel code for large scale particle simulations in cyclotrons. In addition, to meet the running requirement of parallel computation, we have constructed a small scale HPC cluster system and tested its performance. Finally, the high intensity beam dynamics problems in the 100 MeV compact cyclotron, which is being constructed at CIAE, are studied using this code and some conclusions are drawn.

  20. Perspectives on future high energy physics

    Energy Technology Data Exchange (ETDEWEB)

    Samios, N.P.

    1996-12-31

    The author states two general ways in which one must proceed in an attempt to forecast the future of high energy physics. The first is to utilize the state of knowledge in the field and thereby provide theoretical and experimental guidance on future directions. The second approach is technical, namely, how well can one do in going to higher energies with present techniques or new accelerator principles. He concludes that the future strategy is straightforward. The present accelerator facilities must be upgraded and run to produce exciting and forefront research. At the same time, the theoretical tools should be sharpened both extrapolating from lower energies (100 GeV) to high (multi TeV) and vice versa. The US should be involved in the LHC, both in the accelerator and experimental areas. There should be an extensive R and D program on accelerators for a multi-TeV capability, emphasizing e{sup +}e{sup {minus}} and {mu}{sup +}{mu}{sup {minus}} colliders. Finally, the international cooperative activities should be strengthened and maintained.

  1. Increased greenhouse-gas intensity of rice production under future atmospheric conditions

    Science.gov (United States)

    van Groenigen, Kees Jan; van Kessel, Chris; Hungate, Bruce A.

    2013-03-01

    Increased atmospheric CO2 and rising temperatures are expected to affect rice yields and greenhouse-gas (GHG) emissions from rice paddies. This is important, because rice cultivation is one of the largest human-induced sources of the potent GHG methane (CH4) and rice is the world's second-most produced staple crop. The need for meeting a growing global food demand argues for assessing GHG emissions from croplands on the basis of yield rather than land area, such that efforts to reduce GHG emissions take into consideration the consequences for food production. However, it is unclear whether or how the GHG intensity (that is, yield-scaled GHG emissions) of cropping systems will be affected by future atmospheric conditions. Here we show, using meta-analysis, that increased atmospheric CO2 (ranging from 550 to 743ppmV) and warming (ranging from +0.8°C to +6°C) both increase the GHG intensity of rice cultivation. Increased atmospheric CO2 increased GHG intensity by 31.4%, because CH4 emissions are stimulated more than rice yields. Warming increased GHG intensity by 11.8% per 1°C, largely owing to a decrease in yield. This analysis suggests that rising CO2 and warming will approximately double the GHG intensity of rice production by the end of the twenty-first century, stressing the need for management practices that optimize rice production while reducing its GHG intensity as the climate continues to change.

  2. High-field dipoles for future accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Wipf, S.L.

    1984-09-01

    This report presents the concept for building superconducting accelerator dipoles with record high fields. Economic considerations favor the highest possible current density in the windings. Further discussion indicates that there is an optimal range of pinning strength for a superconducting material and that it is not likely for multifilamentary conductors to ever equal the potential performance of tape conductors. A dipole design with a tape-wound, inner high-field winding is suggested. Methods are detailed to avoid degradation caused by flux jumps and to overcome problems with the dipole ends. Concerns for force support structure and field precision are also addressed. An R and D program leading to a prototype 11-T dipole is outlined. Past and future importance of superconductivity to high-energy physics is evident from a short historical survey. Successful dipoles in the 10- to 20-T range will allow interesting options for upgrading present largest accelerators.

  3. SALIVARY CORTISOL RESPONSES AND PERCEIVED EXERTION DURING HIGH INTENSITY AND LOW INTENSITY BOUTS OF RESISTANCE EXERCISE

    Directory of Open Access Journals (Sweden)

    Alison D. Egan

    2004-03-01

    Full Text Available The purpose of this study was to measure the salivary cortisol response to different intensities of resistance exercise. In addition, we wanted to determine the reliability of the session rating of perceived exertion (RPE scale to monitor resistance exercise intensity. Subjects (8 men, 9 women completed 2 trials of acute resistance training bouts in a counterbalanced design. The high intensity resistance exercise protocol consisted of six, ten-repetition sets using 75% of one repetition maximum (RM on a Smith machine squat and bench press exercise (12 sets total. The low intensity resistance exercise protocol consisted of three, ten-repetition sets at 30% of 1RM of the same exercises as the high intensity protocol. Both exercise bouts were performed with 2 minutes of rest between each exercise and sessions were repeated to test reliability of the measures. The order of the exercise bouts was randomized with least 72 hours between each session. Saliva samples were obtained immediately before, immediately after and 30 mins following each resistance exercise bout. RPE measures were obtained using Borg's CR-10 scale following each set. Also, the session RPE for the entire exercise session was obtained 30 minutes following completion of the session. There was a significant 97% increase in the level of salivary cortisol immediately following the high intensity exercise session (P<0.05. There was also a significant difference in salivary cortisol of 145% between the low intensity and high intensity exercise session immediately post-exercise (P<0.05. The low intensity exercise did not result in any significant changes in cortisol levels. There was also a significant difference between the session RPE values for the different intensity levels (high intensity 7.1 vs. low intensity 1.9 (P<0.05. The intraclass correlation coefficient for the session RPE measure was 0.95. It was concluded that the session RPE method is a valid and reliable method of

  4. High Intensity Accelerator and Neutron Source in China

    Science.gov (United States)

    Guan, Xialing; Wei, J.; Loong, Chun

    2011-06-01

    High intensity Accelerator is being studied all over world for numerous applications, which includes the waste transmutation, spallation neutron source and material irradiation facilities. The R/D activities of the technology of High intensity accelerator are also developed in China for some year, and have some good facilities around China. This paper will reports the status of some high intensity accelerators and neutron source in China, which including ADS/RFQ; CARR; CSNS; PKUNIFTY & CPHS. This paper will emphatically report the Compact Pulsed Hadron Source (CPHS) led by the Department of Engineering Physics of Tsinghua University in Beijing, China.

  5. ELECTRON CLOUD EFFECTS IN HIGH INTENSITY PROTON ACCELERATORS.

    Energy Technology Data Exchange (ETDEWEB)

    WEI,J.; MACEK,R.J.

    2002-04-14

    One of the primary concerns in the design and operation of high-intensity proton synchrotrons and accumulators is the electron cloud and associated beam loss and instabilities. Electron-cloud effects are observed at high-intensity proton machines like the Los Alamos National Laboratory's PSR and CERN's SPS, and investigated experimentally and theoretically. In the design of next-generation high-intensity proton accelerators like the Spallation Neutron Source ring, emphasis is made in minimizing electron production and in enhancing Landau damping. This paper reviews the present understanding of the electron-cloud effects and presents mitigation measures.

  6. Investigations on transport and storage of high ion beam intensities

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Ninad Shrikrishna

    2009-08-25

    In the framework of this thesis the intense low energy ion beam transport was investigated. Especially, the beam transport in toroidal magnetic field configurations was discussed, as it may allow the accumulation of high intensive beams in the future. One of the specific tasks is to design an injection system that can be used for the proposed low energy accumulator ring. A simulation code (TBT) was written to describe the particle motion in curved segments. Particle in Cell techniques were utilized to simulate a multi particle dynamics. A possibility of reading an external data file was made available so that a measured distribution can be used to compare simulation results with measured ones. A second order cloud in cell method was used to calculate charge density and in turn to solve Poisson's equation. Further simulations were performed to study the self field effects on beam transport. Experiments were performed to compare the simulation results and gain practical experience. The preparatory experiments consisted of building and characterization of the ion source in a first step. Along with the momentum spectrometer and emittance scanner the beam properties were studied. Low mass ion beams He{sup +} and mixed p, H{sup 2+}, H{sup 3+} beams were analyzed. In the second stage, beams were transported through a solenoid and the phase space distribution was measured as a function of the magnetic field for different beam energies. The phase-space as distributions measured in a first stage were simulated backward and then again forward transported through the solenoid. The simulated results were then compared with the measured distribution. The LINTRA transport program was used. The phase-space distribution was further simulated for transport experiments in a toroidal magnetic field. The transport program that was used to simulate the beam in the toroid was also used to design the injection system. The injection system with its special field configurations was

  7. Repeated high-intensity exercise in professional rugby union.

    Science.gov (United States)

    Austin, Damien; Gabbett, Tim; Jenkins, David

    2011-07-01

    The aim of the present study was to describe the frequency, duration, and nature of repeated high-intensity exercise in Super 14 rugby union. Time-motion analysis was used during seven competition matches over the 2008 and 2009 Super 14 seasons; five players from each of four positional groups (front row forwards, back row forwards, inside backs, and outside backs) were assessed (20 players in total). A repeated high-intensity exercise bout was considered to involve three or more sprints, and/or tackles and/or scrum/ruck/maul activities within 21 s during the same passage of play. The range of repeated high-intensity exercise bouts for each group in a match was as follows: 11-18 for front row forwards, 11-21 for back row forwards, 13-18 for inside backs, and 2-11 for outside backs. The durations of the most intense repeated high-intensity exercise bouts for each position ranged from 53 s to 165 s and the minimum recovery periods between repeated high-intensity exercise bouts ranged from 25 s for the back row forwards to 64 s for the front row forwards. The present results show that repeated high-intensity exercise bouts vary in duration and activities relative to position but all players in a game will average at least 10 changes in activity in the most demanding bouts and complete at least one tackle and two sprints. The most intense periods of activity are likely to last as long as 120 s and as little as 25 s recovery may separate consecutive repeated high-intensity exercise bouts. The present findings can be used by coaches to prepare their players for the most demanding passages of play likely to be experienced in elite rugby union.

  8. The future of high power laser techniques

    Science.gov (United States)

    Poprawe, Reinhart; Loosen, Peter; Hoffmann, Hans-Dieter

    2007-05-01

    High Power Lasers have been used for years in corresponding applications. Constantly new areas and new processes have been demonstrated, developed and transferred to fruitful use in industry. With the advent of diode pumped solid state lasers in the multi-kW-power regime at beam qualities not far away from the diffraction limit, a new area of applicability has opened. In welding applications speeds could be increased and systems could be developed with higher efficiently leading also to new perspectives for increased productivity, e.g. in combined processing. Quality control is increasingly demanded by the applying industries, however applications still are rare. Higher resolution of coaxial process control systems in time and space combined with new strategies in signal processing could give rise to new applications. The general approach described in this paper emphasizes the fact, that laser applications can be developed more efficiently, more precisely and with higher quality, if the laser radiation is tailored properly to the corresponding application. In applying laser sources, the parameter ranges applicable are by far wider and more flexible compared to heat, mechanical or even electrical energy. The time frame ranges from several fs to continuous wave and this spans approximately 15 orders of magnitude. Spacewise, the foci range from several µm to cm and the resulting intensities suitable for materials processing span eight orders of magnitude from 10 3 to 10 11 W/cm2. In addition to space (power, intensity) and time (pulse) the wavelength can be chosen as a further parameter of optimization. As a consequence, the resulting new applications are vast and can be utilized in almost every market segment of our global economy (Fig. 1). In the past and only partly today, however, this flexibility of laser technology is not exploited in full in materials processing, basically because in the high power regime the lasers with tailored beam properties are not

  9. High-intensity interval training evokes larger serum BDNF levels compared with intense continuous exercise.

    Science.gov (United States)

    Saucedo Marquez, Cinthia Maria; Vanaudenaerde, Bart; Troosters, Thierry; Wenderoth, Nicole

    2015-12-15

    Exercise can have a positive effect on the brain by activating brain-derived neurotrophic factor (BDNF)-related processes. In healthy humans there appears to be a linear relationship between exercise intensity and the positive short-term effect of acute exercise on BDNF levels (i.e., the highest BDNF levels are reported after high-intensity exercise protocols). Here we performed two experiments to test the effectiveness of two high-intensity exercise protocols, both known to improve cardiovascular health, to determine whether they have a similar efficacy in affecting BDNF levels. Participants performed a continuous exercise (CON) protocol at 70% of maximal work rate and a high-intensity interval-training (HIT) protocol at 90% of maximal work rate for periods of 1 min alternating with 1 min of rest (both protocols lasted 20 min). We observed similar BDNF kinetics in both protocols, with maximal BDNF concentrations being reached toward the end of training (experiment 1). We then showed that both exercise protocols significantly increase BDNF levels compared with a rest condition (CON P = 0.04; HIT P exercise are slightly more effective than continuous high-intensity exercise for elevating serum BDNF. Additionally, 73% of the participants preferred the HIT protocol (P = 0.02). Therefore, we suggest that the HIT protocol might represent an effective and preferred intervention for elevating BDNF levels and potentially promoting brain health.

  10. High Intensity Tactical Power Sources for the 1990 Army.

    Science.gov (United States)

    conceptual or physical study which may become feasible as high intensity power sources . These considerations include present state of the art of...requirements, energy and power output capabilities, and fixed costs. From these tables, it may be seen that a variety of electrical power sources would be...required to satisfy diverse requirements, but an attempt is made to categorize possible high intensity power sources into their areas of optimum

  11. A review of adolescent high-intensity interval training.

    Science.gov (United States)

    Logan, Greig R M; Harris, Nigel; Duncan, Scott; Schofield, Grant

    2014-08-01

    Despite the promising evidence supporting positive effects of high-intensity interval training (HIIT) on the metabolic profile in adults, there is limited research targeting adolescents. Given the rising burden of chronic disease, it is essential to implement strategies to improve the cardiometabolic health in adolescence, as this is a key stage in the development of healthy lifestyle behaviours. This narrative review summarises evidence of the relative efficacy of HIIT regarding the metabolic health of adolescents. Methodological inconsistencies confound our ability to draw conclusions; however, there is meaningful evidence supporting HIIT as a potentially efficacious exercise modality for use in the adolescent cohort. Future research must examine the effects of various HIIT protocols to determine the optimum strategy to deliver cardiometabolic health benefits. Researchers should explicitly show between-group differences for HIIT intervention and steady-state exercise or control groups, as the magnitude of difference between HIIT and other exercise modalities is of key interest to public health. There is scope for research to examine the palatability of HIIT as an exercise modality for adolescents through investigating perceived enjoyment during and after HIIT, and consequent long-term exercise adherence.

  12. Effect of high intensity ultrasound on the allergenicity of shrimp

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The tropomyosin fraction of shrimp proteins is potentially responsible for allergic reaction in individuals with genetic predisposition to allergy. However, there are no efficient and safe methods to reduce its allergenicity. High intensity ultrasound is known to change the structure of proteins. This study is aimed at assessing high intensity ultrasound's effect on the allergenicity of shrimp allergen. Shrimp and purified shrimp allergen were treated with high intensity ultrasound for 30~180 min. Extracts of treated samples were analyzed by enzyme-linked immunosorbent assay (ELISA) with pool serum of shrimp allergy patients and polyclonal anti-allergen antibodies and by immunoblotting after polyacrylamide gel electrophoresis. Shrimp treated with high intensity ultrasound showed a decrease in allergenicity measured with ELISA. A linear relationship between the immune response induced by treated shrimp allergen and the applied treatment time was observed. The decrease in allergenicity was confirmed by immunoblot assays with shrimp allergic patients serum. Allergenicity of shrimp allergen extracted from treated shrimp was higher than that of purified shrimp allergen with the same treatment time. Gel-filtration HPLC was applied for analysis of shrimp allergen after treatment with high intensity ultrasound. Some fractions were appeared with increasing treatment time. The results suggested that high intensity ultrasound could be used to reduce the allergenicity of shrimp.

  13. Future atmospheric conditions increase the greenhouse gas intensity of rice production

    Science.gov (United States)

    Van Groenigen, K.; Van Kessel, C.; Hungate, B. A.

    2012-12-01

    Elevated levels of atmospheric CO2 and rising temperatures are both expected to alter rice yields and greenhouse gas (GHG) emissions from rice paddies. This is important, because rice cultivation is one of the largest anthropogenic sources of the potent GHG methane (CH4) and rice is the world's second-most produced staple crop. Because global food demand is growing, it makes sense to assess GHG emissions from croplands on the basis of yield rather than land area, so that efforts to reduce GHG emissions occur with taking into consideration the effects on food production. However, it is unclear whether or how the GHG intensity (that is, yield-scaled GHG emissions) of cropping systems will be affected by future atmospheric conditions. Using meta-analysis, we show that elevated atmospheric CO2 (ranging from 550 to 743 ppmV) and warming (ranging from +0.8°C to +6°C) both increase the GHG intensity of rice cultivation. Elevated atmospheric CO2 increased GHG intensity by 31.4%, because CH4 emissions are stimulated more than rice yields. Warming increased GHG intensity by 11.8% per 1°C, largely due to a decrease in yield. Our findings underscore the need for mitigation and adaptation efforts to secure global food supply while at the same time keeping GHG emissions in check.

  14. The future is now: software-guided intensive insulin therapy in the critically ill.

    Science.gov (United States)

    Rattan, Rishi; Nasraway, Stanley A

    2013-03-01

    Since the development of intensive insulin therapy for the critically ill adult, tight glycemic control (TGC) has become increasingly complicated to apply and achieve. Software-guided (SG) algorithms for insulin dosing represent a new method to achieve euglycemia in critical illness. We provide an overview of the state of SG TGC with an eye to the future. The current milieu is disorganized, with little research that incorporates newer variables of dysglycemia, such as glycemic variability. To develop and implement better algorithms, scientists, programmers, and clinicians need to standardize measurements and variables.

  15. Review of High-intensity Interval Training in Cardiac Rehabilitation.

    Science.gov (United States)

    Ito, Shigenori; Mizoguchi, Tatsuya; Saeki, Tomoaki

    2016-01-01

    For the secondary prevention of cardiovascular disease, comprehensive cardiac rehabilitation is required. This involves optimal medical therapy, education on nutrition and exercise therapy, and smoking cessation. Of these, efficient exercise therapy is a key factor. A highly effective training protocol is therefore warranted, which requires a high rate of compliance. Although moderate-intensity continuous training has been the main training regimen recommended in cardiac rehabilitation guidelines, high-intensity interval training has been reported to be more effective in the clinical and experimental setting from the standpoint of peak oxygen uptake and central and peripheral adaptations. In this review, we illustrate the scientific evidence for high-intensity interval training. We then verify this evidence and discuss its significance and the remaining issues.

  16. Benefits of High-Intensity Intensive Care Unit Physician Staffing under the Affordable Care Act

    Directory of Open Access Journals (Sweden)

    Sachin Logani

    2011-01-01

    Full Text Available The Affordable Care Act signed into law by President Obama, with its value-based purchasing program, is designed to link payment to quality processes and outcomes. Treatment of critically ill patients represents nearly 1% of the gross domestic product and 25% of a typical hospital budget. Data suggest that high-intensity staffing patterns in the intensive care unit (ICU are associated with cost savings and improved outcomes. We evaluate the literature investigating the cost-effectiveness and clinical outcomes of high-intensity ICU physician staffing as recommended by The Leapfrog Group (a consortium of companies that purchase health care for their employees and identify ways to overcome barriers to nationwide implementation of these standards. Hospitals that have implemented the Leapfrog initiative have demonstrated reductions in mortality and length of stay and increased cost savings. High-intensity staffing models appear to be an immediate cost-effective way for hospitals to meet the challenges of health care reform.

  17. The generation of high-quality, intense ion beams by ultra-intense lasers

    CERN Document Server

    Roth, M; Audebert, Patrick; Blazevic, A; Brambrink, E; Cowan, T E; Fuchs, J; Gauthier, J C; Geissel, M; Hegelich, M; Karsch, S; Meyer-Ter-Vehn, J; Ruhl, H; Schlegel, T; Stephens, R B

    2002-01-01

    Intense beams of protons and heavy ions have been observed in ultra-intense laser-solid interaction experiments. Thereby, a considerable fraction of the laser energy is transferred to collimated beams of energetic ions (e.g. up to 50 MeV protons; 100 MeV fluorine), which makes these beams highly interesting for various applications. Experimental results indicate a very short-pulse duration and an excellent beam quality, leading to beam intensities in the TW range. To characterize the beam quality and its dependence on laser parameters and target conditions we performed experiments using the 100 TW laser system at Laboratoire pour l'Utilisation des Lasers Intenses at the Ecole Polytechnique, France, with focused intensities exceeding 10 sup 1 sup 9 W cm sup - sup 2. We found a strong dependence on the target rear surface conditions allowing to tailor the ion beam by an appropriate target design. We also succeeded in the generation of heavy ion beams by suppressing the proton amount at the target surface. We wi...

  18. High-intensity light-emitting diode vs fluorescent tubes for intensive phototherapy in neonates.

    Science.gov (United States)

    Sherbiny, Hanan S; Youssef, Doaa M; Sherbini, Ahmad S; El-Behedy, Rabab; Sherief, Laila M

    2016-05-01

    Special blue fluorescent tubes are recommended by the American Academy of Pediatrics (AAP) as the most effective light source for lowering serum bilirubin. A high-intensity light-emitting diode ('super LED') could render intensive phototherapy more effective than the above conventional methods. This study compared the efficacy and safety of a high-intensity light-emitting diode bed vs conventional intensive phototherapy with triple fluorescent tube units as a rescue treatment for severe unconjugated neonatal hyperbilirubinaemia. This was a randomised, prospective trial. Two hundred jaundiced neonates ≥ 35 weeks gestation who met the criteria for intensive phototherapy as per AAP guidelines were randomly assigned to be treated either with triple fluorescent tube units (group 1, n = 100) or a super LED bed (group 2, n = 100). The outcome was the avoidance of exchange transfusion by successful control of hyperbilirubinaemia. Statistically significant higher success rates of intensive phototherapy were achieved among neonates treated with super LED (group 2) than in those treated conventionally (group 1) (87% vs 64%, P = 0.003). Significantly higher 'bilirubin decline' rates were reported in both haemolytic and non-haemolytic subgroups treated with the super LED bed compared with a similar sub-population in the conventionally treated group. Comparable numbers of neonates in both groups developed rebound jaundice (8% vs 10% of groups 1 and 2, respectively). Side-effects were mild in both groups, but higher rates of hyperthermia (12% vs 0%, P = 0.03), dehydration (8% vs 2%, P = 0.26) and skin rash (39% vs 1%, P = 0.002) were reported in the fluorescent tubes-treated group compared with the LED group. Super LED is a safe rescue treatment for severe neonatal hyperbilirubinaemia, and its implementation may reduce the need for exchange transfusion.

  19. Simulation study of the high intensity S-Band photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Xiongwei; Nakajima, Kazuhisa [High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)

    2001-10-01

    In this paper, we report the results of simulation study of the high intensity S-Band photoinjector. The aim of the simulation study is to transport high bunch charge with low emittance evolution. The simulation result shows that 7nC bunch with rms emittance 22.3 {pi} mm mrad can be outputted at the exit of photoinjector. (author)

  20. Acute plasma volume change with high-intensity sprint exercise.

    Science.gov (United States)

    Bloomer, Richard J; Farney, Tyler M

    2013-10-01

    When exercise is of long duration or of moderate to high intensity, a decrease in plasma volume can be observed. This has been noted for both aerobic and resistance exercise, but few data are available with regard to high-intensity sprint exercise. We measured plasma volume before and after 3 different bouts of acute exercise, of varying intensity, and/or duration. On different days, men (n = 12; 21-35 years) performed aerobic cycle exercise (60 minutes at 70% heart rate reserve) and 2 different bouts of cycle sprints (five 60-second sprints at 100% maximum wattage obtained during graded exercise testing (GXT) and ten 15-second sprints at 200% maximum wattage obtained during GXT). Blood was collected before and 0, 30, and 60 minutes postexercise and analyzed for hematocrit and hemoglobin and plasma volume was calculated. Plasma volume decreased significantly for all exercise bouts (p sprint bouts (∼19%) compared with aerobic exercise bouts (∼11%). By 30 minutes postexercise, plasma volume approached pre-exercise values. We conclude that acute bouts of exercise, in particular high-intensity sprint exercise, significantly decrease plasma volume during the immediate postexercise period. It is unknown what, if any negative implications these transient changes may have on exercise performance. Strength and conditioning professionals may aim to rehydrate athletes appropriately after high-intensity exercise bouts.

  1. Generation of Intense High-Order Vortex Harmonics

    CERN Document Server

    Zhang, Xiaomei; Shi, Yin; Wang, Xiaofeng; Zhang, Lingang; Wang, Wenpeng; Xu, Jiancai; Yi, Longqiong; Xu, Zhizhan

    2014-01-01

    This paper presents the method for the first time to generate intense high-order optical vortices that carry orbital angular momentum in the extreme ultraviolet region. In three-dimensional particle-in-cell simulation, both the reflected and transmitted light beams include high-order harmonics of the Laguerre-Gaussian (LG) mode when a linearly polarized LG laser pulse impinges on a solid foil. The mode of the generated LG harmonic scales with its order, in good agreement with our theoretical analysis. The intensity of the generated high-order vortex harmonics is close to the relativistic region, and the pulse duration can be in attosecond scale. The obtained intense vortex beam possesses the combined properties of fine transversal structure due to the high-order mode and the fine longitudinal structure due to the short wavelength of the high-order harmonics. Thus, the obtained intense vortex beam may have extraordinarily promising applications for high-capacity quantum information and for high-resolution dete...

  2. High Intensity Particle Physics at PW-class laser facilities

    Science.gov (United States)

    Bulanov, Stepan; Schroeder, Carl; Esarey, Eric; Esirkepov, Timur; Kando, Masaki; Rosanov, Nikolay; Korn, Georg; Bulanov, Sergey V.; Leemans, Wim P.

    2015-11-01

    The processes typical for high intensity particle physics, i.e., the interactions of charged particles with strong electromagnetic fields, have attracted considerable interest recently. Some of these processes, previously believed to be of theoretical interest only, are now becoming experimentally accessible. High intensity electromagnetic (EM) fields significantly modify the interactions of particles and EM fields, giving rise to the phenomena that are not encountered either in classical or perturbative quantum theory of these interactions. One of such phenomena is the radiation reaction, which radically influences the electron motion in an electromagnetic standing wave formed by two super-intense counter-propagating laser pulses. Depending on the laser intensity and wavelength, either classical or quantum mode of radiation reaction prevail, or both are strong. When radiation reaction dominates, electron motion evolves to limit cycles and strange attractors. This creates a new framework for high energy physics experiments on an interaction of energetic charged particle beams and colliding super-intense laser pulses. Work supported by U.S. DOE under Contract No. DE-AC02-05CH11231.

  3. Light-intensity and high-intensity interval training improve cardiometabolic health in rats.

    Science.gov (United States)

    Batacan, Romeo B; Duncan, Mitch J; Dalbo, Vincent J; Connolly, Kylie J; Fenning, Andrew S

    2016-09-01

    Physical activity has the potential to reduce cardiometabolic risk factors but evaluation of different intensities of physical activity and the mechanisms behind their health effects still need to be fully established. This study examined the effects of sedentary behaviour, light-intensity training, and high-intensity interval training on biometric indices, glucose and lipid metabolism, inflammatory and oxidative stress markers, and vascular and cardiac function in adult rats. Rats (12 weeks old) were randomly assigned to 1 of 4 groups: control (CTL; no exercise), sedentary (SED; no exercise and housed in small cages to reduce activity), light-intensity trained (LIT; four 30-min exercise bouts/day at 8 m/min separated by 2-h rest period, 5 days/week), and high-intensity interval trained (HIIT, four 2.5-min work bouts/day at 50 m/min separated by 3-min rest periods, 5 days/week). After 12 weeks of intervention, SED had greater visceral fat accumulation (p < 0.01) and slower cardiac conduction (p = 0.04) compared with the CTL group. LIT and HIIT demonstrated beneficial changes in body weight, visceral and epididymal fat weight, glucose regulation, low-density lipoprotein cholesterol, total cholesterol, and mesenteric vessel contractile response compared with the CTL group (p < 0.05). LIT had significant improvements in insulin sensitivity and cardiac conduction compared with the CTL and SED groups whilst HIIT had significant improvements in systolic blood pressure and endothelium-independent vasodilation to aorta and mesenteric artery compared with the CTL group (p < 0.05). LIT and HIIT induce health benefits by improving traditional cardiometabolic risk factors. LIT improves cardiac health while HIIT promotes improvements in vascular health.

  4. Renewable Electricity Futures Study. Volume 1. Exploration of High-Penetration Renewable Electricity Futures

    Energy Technology Data Exchange (ETDEWEB)

    Hand, M. M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Baldwin, S. [U.S. Dept. of Energy, Washington, DC (United States); DeMeo, E. [Renewable Energy Consulting, Chicago, IL (United States); Reilly, J. M. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Mai, T. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Arent, D. [Joint Inst. for Strategic Energy Analysis, Boulder, CO (United States); Porro, G. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Meshek, M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sandor, D. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2012-06-15

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%–90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT). Learn more at the RE Futures website. http://www.nrel.gov/analysis/re_futures/

  5. Thomson scattering in high-intensity chirped laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Holkundkar, Amol R., E-mail: amol.holkundkar@pilani.bits-pilani.ac.in [Department of Physics, Birla Institute of Technology and Science, Pilani, Rajasthan 333031 (India); Harvey, Chris, E-mail: christopher.harvey@chalmers.se; Marklund, Mattias, E-mail: mattias.marklund@chalmers.se [Department of Applied Physics, Chalmers University of Technology, SE-41296 Gothenburg (Sweden)

    2015-10-15

    We consider the Thomson scattering of an electron in an ultra-intense laser pulse. It is well known that at high laser intensities, the frequency and brilliance of the emitted radiation will be greatly reduced due to the electron losing energy before it reaches the peak field. In this work, we investigate the use of a small frequency chirp in the laser pulse in order to mitigate this effect of radiation reaction. It is found that the introduction of a negative chirp means the electron enters a high frequency region of the field while it still has a large proportion of its original energy. This results in a significant enhancement of the frequency and intensity of the emitted radiation as compared to the case without chirping.

  6. Plasma-based polarization modulator for high-intensity lasers

    Science.gov (United States)

    Chen, Zi-Yu; Pukhov, Alexander

    2016-12-01

    Manipulation of laser pulses at high intensities is an important yet challenging issue. New types of plasma-based optical devices are promising alternatives to achieve this goal. Here we propose to modulate the polarization state of intense lasers based on oblique reflection from solid-plasma surfaces. A new analytical description is presented considering the plasma as an uniaxial medium that causes birefringence effect. Particle-in-cell simulation results numerically demonstrate that such a scheme can provide a tunable polarization control of the laser pulses even in the relativistic regime. The results are thus relevant for the design of compact, easy to use, and versatile polarization modulators for high-intensity laser pulses.

  7. Self-trapping of intensities changing under SHG and SWG for high intensive femtosecond laser pulse

    Science.gov (United States)

    Trofimov, Vyacheslav A.; Kharitonov, Dmitry M.; Fedotov, Mikhail V.

    2017-05-01

    SHG and SFG (SWG) and THG are used widely in many practical applications such as a substance diagnostics, and imaging of various physical, chemical and biological processes as well as for laser radiation frequency conversion. One of very interesting phenomena under the frequency conversion takes place if a basic wave incident intensity is enough high: a synchronic mode of the laser pulse intensities changing along a propagation coordinate appears under certain conditions. First of all, we investigate this phenomenon using the frame-work of long pulse duration approximation and plane wave approximation without applying the basic wave energy non-depletion approximation. Applying an original approach we derive the solution of Schr¨odinger equations describing the THG via a SHG process and summary frequency wave generation (SFG) process for femtosecond pulses. Among many modes of the frequency conversion process under consideration we found out analytically the mode corresponding to synchronous intensities changing for the interacting waves. We derive conditions of such mode realization in dependence of the problem parameters. After that we verify our analytical consideration using a computer simulation of the problem on the base of the corresponding Schr¨odinger equations. Computer simulation shown also a new phenomenon at three-wave interaction: interacting wave intensities changing with two (or more) oscillation periods.

  8. Some Intensive and Extensive Quantities in High-Energy Collisions

    CERN Document Server

    Tawfik, A

    2013-01-01

    We review the evolution of some statistical and thermodynamical quantities measured in difference sizes of high-energy collisions at different energies. We differentiate between intensive and extensive quantities and discuss the importance of their distinguishability in characterizing possible critical phenomena of nuclear collisions at various energies with different initial conditions.

  9. High-Intensity Interval Training for Improving Postprandial Hyperglycemia

    Science.gov (United States)

    Little, Jonathan P.; Francois, Monique E.

    2014-01-01

    High-intensity interval training (HIIT) has garnered attention in recent years as a time-efficient exercise option for improving cardiovascular and metabolic health. New research demonstrates that HIIT may be particularly effective for improving postprandial hyperglycemia in individuals with, or at risk for, type 2 diabetes (T2D). These findings…

  10. Nonlinear Behavior in High-Intensity Discharge Lamps

    CERN Document Server

    Baumann, Bernd; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2015-01-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behaves very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  11. Nonlinear behavior in high-intensity discharge lamps

    Science.gov (United States)

    Baumann, Bernd; Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2016-06-01

    The light flicker problem of high intensity discharge lamps is studied numerically and experimentally. It is shown that in some respects the systems behave very similar to the forced Duffing oscillator with a softening spring. In particular, the jump phenomenon and hysteresis are observed in the simulations and in the experiments.

  12. Parallel Beam Dynamics Code Development for High Intensity Cyclotron

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    <正>1 Parallel PIC algorithm Self field solver is the key part of a high intensity beam dynamic PIC code which usually adopts the P-M (Particle-Mesh) method to solve the space charge. The P-M method is composed of four major

  13. Annotated bibliography on high-intensity linear accelerators. [240 citations

    Energy Technology Data Exchange (ETDEWEB)

    Jameson, R.A.; Roybal, E.U.

    1978-01-01

    A technical bibliography covering subjects important to the design of high-intensity beam transport systems and linear accelerators is presented. Space charge and emittance growth are stressed. Subject and author concordances provide cross-reference to detailed citations, which include an abstract and notes on the material. The bibliography resides in a computer database that can be searched for key words and phrases.

  14. Intense neutron source: high-voltage power supply specifications

    Energy Technology Data Exchange (ETDEWEB)

    Riedel, A.A.

    1980-08-01

    This report explains the need for and sets forth the electrical, mechanical and safety specifications for a high-voltage power supply to be used with the intense neutron source. It contains sufficient information for a supplier to bid on such a power supply.

  15. Reuse Recycler: High Intensity Proton Stacking at Fermilab

    Energy Technology Data Exchange (ETDEWEB)

    Adamson, P. [Fermilab

    2016-07-17

    After a successful career as an antiproton storage and cooling ring, Recycler has been converted to a high intensity proton stacker for the Main Injector. We discuss the commissioning and operation of the Recycler in this new role, and the progress towards the 700 kW design goal.

  16. Production of High-Intensity, Highly Charged Ions

    CERN Document Server

    Gammino, S

    2013-01-01

    In the past three decades, the development of nuclear physics facilities for fundamental and applied science purposes has required an increasing current of multicharged ion beams. Multiple ionization implies the formation of dense and energetic plasmas, which, in turn, requires specific plasma trapping configurations. Two types of ion source have been able to produce very high charge states in a reliable and reproducible way: electron beam ion sources (EBIS) and electron cyclotron resonance ion sources (ECRIS). Multiple ionization is also obtained in laser-generated plasmas (laser ion sources (LIS)), where the high-energy electrons and the extremely high electron density allow step-by-step ionization, but the reproducibility is poor. This chapter discusses the atomic physics background at the basis of the production of highly charged ions and describes the scientific and technological features of the most advanced ion sources. Particular attention is paid to ECRIS and the latest developments, since they now r...

  17. Renewable Electricity Futures Study. Volume 1: Exploration of High-Penetration Renewable Electricity Futures

    Energy Technology Data Exchange (ETDEWEB)

    Mai, T.; Wiser, R.; Sandor, D.; Brinkman, G.; Heath, G.; Denholm, P.; Hostick, D.J.; Darghouth, N.; Schlosser, A.; Strzepek, K.

    2012-06-01

    The Renewable Electricity Futures (RE Futures) Study investigated the challenges and impacts of achieving very high renewable electricity generation levels in the contiguous United States by 2050. The analysis focused on the sufficiency of the geographically diverse U.S. renewable resources to meet electricity demand over future decades, the hourly operational characteristics of the U.S. grid with high levels of variable wind and solar generation, and the potential implications of deploying high levels of renewables in the future. RE Futures focused on technical aspects of high penetration of renewable electricity; it did not focus on how to achieve such a future through policy or other measures. Given the inherent uncertainties involved with analyzing alternative long-term energy futures as well as the multiple pathways that might be taken to achieve higher levels of renewable electricity supply, RE Futures explored a range of scenarios to investigate and compare the impacts of renewable electricity penetration levels (30%-90%), future technology performance improvements, potential constraints to renewable electricity development, and future electricity demand growth assumptions. RE Futures was led by the National Renewable Energy Laboratory (NREL) and the Massachusetts Institute of Technology (MIT).

  18. Production of High-Intensity, Highly Charged Ions

    OpenAIRE

    S. GamminoINFN, LNS, Catania

    2014-01-01

    In the past three decades, the development of nuclear physics facilities for fundamental and applied science purposes has required an increasing current of multicharged ion beams. Multiple ionization implies the formation of dense and energetic plasmas, which, in turn, requires specific plasma trapping configurations. Two types of ion source have been able to produce very high charge states in a reliable and reproducible way: electron beam ion sources (EBIS) and electron cyc...

  19. CW high intensity non-scaling FFAG proton drivers

    CERN Document Server

    Johnstone, C; Makino, K; Snopok, P

    2012-01-01

    Accelerators are playing increasingly important roles in basic science, technology, and medicine including nuclear power, industrial irradiation, material science, and neutrino production. Proton and light-ion accelerators in particular have many research, energy and medical applications, providing one of the most effective treatments for many types of cancer. Ultra high-intensity and high-energy (GeV) proton drivers are a critical technology for accelerator-driven sub-critical reactors (ADS) and many HEP programs (Muon Collider). These high-intensity GeV-range proton drivers are particularly challenging, encountering duty cycle and space-charge limits in the synchrotron and machine size concerns in the weaker-focusing cyclotrons; a 10-20 MW proton driver is not presently considered technically achievable with conventional re-circulating accelerators. One, as-yet, unexplored re-circulating accelerator, the Fixed-field Alternating Gradient, or FFAG, is an attractive alternative to the cyclotron. Its strong foc...

  20. Ultra High Performance, Highly Reliable, Numeric Intensive Processors and Systems

    Science.gov (United States)

    1989-10-01

    to design high-performance DSP/IP systems using either off-the-shelf components or application specific integrated circuitry [ ASIC ]. -9 - HSDAL . ARO...are the chirp-z transform ( CZT ) [13] and (Rader’s) Prime Factor Transform (PFT) [11]. The RNS/ CZT is being studied by a group a MITRE [14] and is given...PFT RNS/CRNS/QRNS implementation has dynamic range requirements on the order of NQ2 (vs NQ4 for the CZT and much higher for the FFT). Therefore, the

  1. Surface phase defects induced downstream laser intensity modulation in high-power laser facility

    Institute of Scientific and Technical Information of China (English)

    Xin Zhang; Wei Zhou; Wanjun Dai; Dongxia Hu; Xuewei Deng; Wanqing Huang; Lidan Zhou; Qiang Yuan; Xiaoxia Huang; De’en Wang; Ying Yang

    2016-01-01

    Optics surface phase defects induced intensity modulation in high-power laser facility for inertial confinement fusion research is studied. Calculations and experiments reveal an exact mapping of the modulation patterns and the optics damage spot distributions from the surface phase defects. Origins are discussed during the processes of optics manufacturing and diagnostics, revealing potential improvements for future optics manufacturing techniques and diagnostic index, which is meaningful for fusion level laser facility construction and its operation safety.

  2. Generation of Ultra-high Intensity Laser Pulses

    Energy Technology Data Exchange (ETDEWEB)

    N.J. Fisch; V.M. Malkin

    2003-06-10

    Mainly due to the method of chirped pulse amplification, laser intensities have grown remarkably during recent years. However, the attaining of very much higher powers is limited by the material properties of gratings. These limitations might be overcome through the use of plasma, which is an ideal medium for processing very high power and very high total energy. A plasma can be irradiated by a long pump laser pulse, carrying significant energy, which is then quickly depleted in the plasma by a short counterpropagating pulse. This counterpropagating wave effect has already been employed in Raman amplifiers using gases or plasmas at low laser power. Of particular interest here are the new effects which enter in high power regimes. These new effects can be employed so that one high-energy optical system can be used like a flashlamp in what amounts to pumping the plasma, and a second low-power optical system can be used to extract quickly the energy from the plasma and focus it precisely. The combined system can be very compact. Thus, focused intensities more than 10{sup 25} W/cm{sup 2} can be contemplated using existing optical elements. These intensities are several orders of magnitude higher than what is currently available through chirped pump amplifiers.

  3. A transparent vacuum window for high-intensity pulsed beams

    CERN Document Server

    Monteil, M; Veness, R

    2011-01-01

    The HiRadMat (High-Radiation to Materials) facility Ill will allow testing of accelerator components, in particular those of the Large Hadron Collider (LHC) at CERN, under the impact of high-intensity pulsed beams. To reach this intensity range, the beam will be focused on a focal point where the target to be tested is located. A 60 mm aperture vacuum window will separate the vacuum of the beam line which is kept under high vacuum 10(-8) mbar, from the test area which is at atmospheric pressure. This window has to resist collapse due to beam passage. The high-intensity of the beam means that typical materials used for standard vacuum windows (such as stainless steel, aluminium and titanium alloy) cannot endure the energy deposition induced by the beam passage. Therefore, a vacuum window has been designed to maintain the differential pressure whilst resisting collapse due to the beam impact on the window. In this paper, we will present calculations of the energy transfer from beam to window, the design of the ...

  4. Atmosphere-Ocean Coupling Effect on Intense Tropical Cyclone Distribution and its Future Change with 60 km-AOGCM

    Science.gov (United States)

    Ogata, Tomomichi; Mizuta, Ryo; Adachi, Yukimasa; Murakami, Hiroyuki; Ose, Tomoaki

    2016-07-01

    Atmosphere-ocean coupling effect on the frequency distribution of tropical cyclones (TCs) and its future change is studied using an atmosphere and ocean coupled general circulation model (AOGCM). In the present climate simulation, the atmosphere-ocean coupling in the AOGCM improves biases in the AGCM such as the poleward shift of the maximum of intense TC distribution in the Northern Hemisphere and too many intense TCs in the Southern Hemisphere. Particularly, subsurface cold water plays a key role to reduce these AGCM biases of intense TC distribution. Besides, the future change of intense TC distribution is significantly different between AOGCM and AGCM despite the same monthly SST. In the north Atlantic, subsurface warming causes larger increase in frequency of intense TCs in AOGCM than that in AGCM. Such subsurface warming in AOGCM also acts to alter large decrease of intense TC in AGCM to no significant change in AOGCM over the southwestern Indian Ocean. These results suggest that atmosphere-ocean coupling characterized by subsurface oceanic structure is responsible for more realistic intense TC distribution in the current climate simulation and gives significant impacts on its future projection.

  5. Atmosphere-Ocean Coupling Effect on Intense Tropical Cyclone Distribution and its Future Change with 60 km-AOGCM.

    Science.gov (United States)

    Ogata, Tomomichi; Mizuta, Ryo; Adachi, Yukimasa; Murakami, Hiroyuki; Ose, Tomoaki

    2016-07-15

    Atmosphere-ocean coupling effect on the frequency distribution of tropical cyclones (TCs) and its future change is studied using an atmosphere and ocean coupled general circulation model (AOGCM). In the present climate simulation, the atmosphere-ocean coupling in the AOGCM improves biases in the AGCM such as the poleward shift of the maximum of intense TC distribution in the Northern Hemisphere and too many intense TCs in the Southern Hemisphere. Particularly, subsurface cold water plays a key role to reduce these AGCM biases of intense TC distribution. Besides, the future change of intense TC distribution is significantly different between AOGCM and AGCM despite the same monthly SST. In the north Atlantic, subsurface warming causes larger increase in frequency of intense TCs in AOGCM than that in AGCM. Such subsurface warming in AOGCM also acts to alter large decrease of intense TC in AGCM to no significant change in AOGCM over the southwestern Indian Ocean. These results suggest that atmosphere-ocean coupling characterized by subsurface oceanic structure is responsible for more realistic intense TC distribution in the current climate simulation and gives significant impacts on its future projection.

  6. Atmosphere-Ocean Coupling Effect on Intense Tropical Cyclone Distribution and its Future Change with 60 km-AOGCM

    Science.gov (United States)

    Ogata, Tomomichi; Mizuta, Ryo; Adachi, Yukimasa; Murakami, Hiroyuki; Ose, Tomoaki

    2016-01-01

    Atmosphere-ocean coupling effect on the frequency distribution of tropical cyclones (TCs) and its future change is studied using an atmosphere and ocean coupled general circulation model (AOGCM). In the present climate simulation, the atmosphere-ocean coupling in the AOGCM improves biases in the AGCM such as the poleward shift of the maximum of intense TC distribution in the Northern Hemisphere and too many intense TCs in the Southern Hemisphere. Particularly, subsurface cold water plays a key role to reduce these AGCM biases of intense TC distribution. Besides, the future change of intense TC distribution is significantly different between AOGCM and AGCM despite the same monthly SST. In the north Atlantic, subsurface warming causes larger increase in frequency of intense TCs in AOGCM than that in AGCM. Such subsurface warming in AOGCM also acts to alter large decrease of intense TC in AGCM to no significant change in AOGCM over the southwestern Indian Ocean. These results suggest that atmosphere-ocean coupling characterized by subsurface oceanic structure is responsible for more realistic intense TC distribution in the current climate simulation and gives significant impacts on its future projection. PMID:27418240

  7. Heat transparent high intensity high efficiency solar cell

    Science.gov (United States)

    Evans, J. C., Jr. (Inventor)

    1982-01-01

    An improved solar cell design is described. A surface of each solar cell has a plurality of grooves. Each groove has a vertical face and a slanted face that is covered by a reflecting metal. Light rays are reflected from the slanted face through the vertical face where they traverse a photovoltaic junction. As the light rays travel to the slanted face of an adjacent groove, they again traverse the junction. The underside of the reflecting coating directs the light rays toward the opposite surface of solar cell as they traverse the junction again. When the light rays travel through the solar cell and reach the saw toothed grooves on the under side, the process of reflection and repeatedly traversing the junction again takes place. The light rays ultimately emerge from the solar cell. These solar cells are particularly useful at very high levels of insolation because the infrared or heat radiation passes through the cells without being appreciably absorbed to heat the cell.

  8. Fermilab main injector: High intensity operation and beam loss control

    Science.gov (United States)

    Brown, Bruce C.; Adamson, Philip; Capista, David; Chou, Weiren; Kourbanis, Ioanis; Morris, Denton K.; Seiya, Kiyomi; Wu, Guan Hong; Yang, Ming-Jen

    2013-07-01

    From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at 400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about 1.5 kW of beam loss. By minimizing and localizing loss, residual radiation levels fell while beam power was doubled. Lost beam was directed to either the collimation system or to the beam abort. Critical apertures were increased while improved instrumentation allowed optimal use of available apertures. We will summarize the improvements required to achieve high intensity, the impact of various loss control tools and the status and trends in residual radiation in the Main Injector.

  9. High Performance Monopropellants for Future Planetary Ascent Vehicles Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Physical Sciences Inc. proposes to design, develop, and demonstrate, a novel high performance monopropellant for application in future planetary ascent vehicles. Our...

  10. Future scientific applications for high-energy lasers

    Energy Technology Data Exchange (ETDEWEB)

    Lee, R.W. [comp.

    1994-08-01

    This report discusses future applications for high-energy lasers in the areas of astrophysics and space physics; hydrodynamics; material properties; plasma physics; radiation sources; and radiative properties.

  11. Low-intensity resistance training after high-intensity resistance training can prevent the increase of central arterial stiffness.

    Science.gov (United States)

    Okamoto, T; Masuhara, M; Ikuta, K

    2013-05-01

    Although high-intensity resistance training increases arterial stiffness, low-intensity resistance training reduces arterial stiffness. The present study investigates the effect of low-intensity resistance training before and after high-intensity resistance training on arterial stiffness. 30 young healthy subjects were randomly assigned to a group that performed low-intensity resistance training before high-intensity resistance training (BLRT, n=10), a group that performed low-intensity resistance training after high-intensity resistance training (ALRT, n=10) and a sedentary control group (n=10). The BLRT and ALRT groups performed resistance training at 80% and 50% of one repetition maximum twice each week for 10 wk. Arterial stiffness was measured using carotid-femoral and femoral-ankle pulse wave velocity (PWV). One-repetition maximum strength in the both ALRT and BLRT significantly increased after the intervention (Ptraining in the ALRT group did not change from before training. In contrast, carotid-femoral PWV after combined training in the BLRT group increased from before training (P training in the both BLRT and ALRT groups did not change from before training. These results suggest that although arterial stiffness is increased by low-intensity resistance training before high-intensity resistance training, performing low-intensity resistance training thereafter can prevent the increase of arterial stiffness. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Spallation neutron source and other high intensity froton sources

    Energy Technology Data Exchange (ETDEWEB)

    Weiren Chou

    2003-02-06

    This lecture is an introduction to the design of a spallation neutron source and other high intensity proton sources. It discusses two different approaches: linac-based and synchrotron-based. The requirements and design concepts of each approach are presented. The advantages and disadvantages are compared. A brief review of existing machines and those under construction and proposed is also given. An R&D program is included in an appendix.

  13. Entrepreneurship in high-tech and knowledge-intensive sectors

    DEFF Research Database (Denmark)

    Christensen, Patrizia V.; Madsen, Henning; Neergaard, Helle

    development of new enterprises in high-tech and knowledge-intensive sectors are analysed in relation to the educational and professional background of the entrepreneur/entrepreneurial team, as well as the personal and professional social networks of the entrepreneurs. The analysis is based on a theoretical...... framework combining theories of human and social capital. Secondary aspects addressed in the research project are questions of male vs. female entrepreneurship, internationalisation-globalisation, and business success/failure....

  14. Future Expectations of High School Students In Southeastern Turkey: Factors behind Future Expectations

    Directory of Open Access Journals (Sweden)

    Hüseyin Şimşek

    2012-01-01

    Full Text Available This study was conducted to identify various future expectations of high school students in southeastern Turkey and factors behind their expectations. The sample of the study, which had a descriptive and associational survey design consisted of 1106 students randomly selected from 54 different high schools located in nine cities in southeastern Turkey. Data were collected through the “Future Expectation Scale (FES” developed by the researcher. Results indicated that personal and professional future, educational future, economic future and social future expectations of high school students in southeastern Turkey were generally above the average level. According to the study, being a teacher and a doctor took the first place among several professions to be further preferred by high school students. It was also concluded that future expectations of high school students did not differ on gender, high school type, CGPA, level of mother education, father’s occupation, family income level, the number of siblings, receiving pre-school education, and language spoken at home. On the other hand, future expectations of high school students were found to differ on the city where students being taught, grade level, corporal punishment, and tendency toward being a dropout.

  15. High-intensity interval training and athletic performance in Taekwondo athletes.

    Science.gov (United States)

    Monks, Lynne; Seo, Myong-Won; Kim, Hyun-Bae; Jung, Hyun C; Song, Jong K

    2017-10-01

    The purpose of this study was to determine the effects of high-intensity interval training (HIIT) on athletic performance in Taekwondo athletes. Thirty-three male and female collegiate Taekwondo athletes were randomly divided into a HIIT group (N.=16) or a high-intensity continuous running (HICR) group (N.=17). The HIIT group undertook training of high-intensity sprints interspersed with active rest periods whilst the HICR group participated in high-intensity running for a continuous period. Both groups completed 11 sessions over 4 weeks. Physique, body composition, Wingate anaerobic test and VO2max test were measured. The vertical jump test, agility T-test and sit-ups were used to assess physical fitness. Repeated measures ANCOVAs with sex as a covariate were applied and significant level was set at 0.05. Following 11 sessions of training, significant improvements in anaerobic peak power (PTaekwondo competition performance in collegiate Taekwondo athletes. This could inform the future planning of Taekwondo athletes' pre-competition training, specifically the influence of training intensity on anaerobic capacity.

  16. Compton spectra of atoms at high x-ray intensity

    Science.gov (United States)

    Son, Sang-Kil; Geffert, Otfried; Santra, Robin

    2017-03-01

    Compton scattering is the nonresonant inelastic scattering of an x-ray photon by an electron and has been used to probe the electron momentum distribution in gas-phase and condensed-matter samples. In the low x-ray intensity regime, Compton scattering from atoms dominantly comes from bound electrons in neutral atoms, neglecting contributions from bound electrons in ions and free (ionized) electrons. In contrast, in the high x-ray intensity regime, the sample experiences severe ionization via x-ray multiphoton multiple ionization dynamics. Thus, it becomes necessary to take into account all the contributions to the Compton scattering signal when atoms are exposed to high-intensity x-ray pulses provided by x-ray free-electron lasers (XFELs). In this paper, we investigate the Compton spectra of atoms at high x-ray intensity, using an extension of the integrated x-ray atomic physics toolkit, xatom. As the x-ray fluence increases, there is a significant contribution from ionized electrons to the Compton spectra, which gives rise to strong deviations from the Compton spectra of neutral atoms. The present study provides not only understanding of the fundamental XFEL-matter interaction but also crucial information for single-particle imaging experiments, where Compton scattering is no longer negligible. , which features invited work from the best early-career researchers working within the scope of J. Phys. B. This project is part of the Journal of Physics series’ 50th anniversary celebrations in 2017. Sang-Kil Son was selected by the Editorial Board of J. Phys. B as an Emerging Leader.

  17. Intelligent Controller of Digital High Intensity Discharge Lamp

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    High-intensity discharge (HID) lamps include these types of electrical lamps: mercury vapor, metal halide (also HQI), high-pressure sodium, low-pressure sodium and less commonly, xenon short-arc lamps. The light-producing element of these lamp types is a well-stabilized arc discharge contained within a refractory envelope (arc tube) with wall loading in excess of 3 W/cm (19.4 W/in.). Compared to fluorescent and incandescent lamps, HID lamps produce a much larger quantity of light in a relatively small package. With tests made by the National Quality Supervision and

  18. The joint project for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-08-01

    Japan Atomic Energy Research Institute (JAERI) and the High Energy Accelerator Research Organization (KEK) agreed to promote the joint project integrating both the Neutron Science Project (NSP) of JAERI and the Japan Hadron Facility Project (JHF) of KEK for comprehensive studies on basic science and technology using high-intensity proton accelerator. This document describes the joint proposal prepared by the Joint Project Team of JAERI and KEK to construct accelerators and research facilities necessary both for the NSP and the JHF at the site of JAERI Tokai Establishment. (author)

  19. High intensity Discharge lighting; Alumbrado de alta intensidad de descarga

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza E, Ernesto J. [Manufacturera de Reactores, S. A., Mexico, D. F. (Mexico)

    1993-12-31

    This paper gets into contact with some fundamentals in the operation of high discharge intensity lamps. There are useful definitions, as well as the study of the operation of high pressure sodium lamps and of metallic additives operating at less than nominal power. [Espanol] Este trabajo pone al lector en contacto con algunos fundamentos de la operacion de las lamparas de alta intensidad de descarga (HID). Se encuentra con definiciones utiles, asi como el estudio de la operacion de las lamparas de sodio en alta presion y de aditivos metalicos operando a una potencia menor que la nominal.

  20. Removing Known SPS Intensity Limitations for High Luminosity LHC Goals

    CERN Document Server

    Shaposhnikova, Elena; Bohl, Thomas; Cruikshank, Paul; Goddard, Brennan; Kaltenbacher, Thomas; Lasheen, Alexandre; Perez Espinos, Jaime; Repond, Joël; Salvant, Benoit; Vollinger, Christine

    2016-01-01

    In preparation of the SPS as an LHC injector its impedance was significantly reduced in 1999 - 2000. A new SPS impedance reduction campaign is planned now for the High Luminosity (HL)-LHC project, which requires bunch intensities twice as high as the nominal one. One of the known intensity limitations is a longitudinal multi-bunch instability with a threshold 3 times below this operational intensity. The instability is presently cured using the 4th harmonic RF system and controlled emittance blow-up, but reaching the HL-LHC parameters cannot be assured without improving the machine impedance. Recently the impedance sources responsible for this instability were identified and implementation of their shielding and damping is foreseen during the next long shutdown (2019 - 2020) in synergy with two other important upgrades: amorphous carbon coating of (part of) the vacuum chamber against the e-cloud effect and rearrangement of the 200 MHz RF system. In this paper the strategy of impedance reduction is presented t...

  1. High-intensity positron microprobe at Jefferson Lab

    CERN Document Server

    Golge, Serkan; Wojtsekhowski, Bogdan

    2014-01-01

    We present a conceptual design for a novel continuous wave electron-linac based high-intensity slow-positron production source with a projected intensity on the order of 10$^{10}$ e$^+$/s. Reaching this intensity in our design relies on the transport of positrons (T$_+$ below 600 keV) from the electron-positron pair production converter target to a low-radiation and low-temperature area for moderation in a high-efficiency cryogenic rare gas moderator, solid Ne. The performance of the integrated beamline has been verified through computational studies. The computational results include Monte Carlo calculations of the optimized electron/positron beam energies, converter target thickness, synchronized raster system, transport of the beam from the converter target to the moderator, extraction of the beam from the channel, and moderation efficiency calculations. For the extraction of positrons from the magnetic channel a magnetic field terminator plug prototype has been built and experimental data on the effective...

  2. FNAL Proton Source High Intensity Operations and Beam Loss Control

    CERN Document Server

    Garcia, F G

    2014-01-01

    The 40-year-old Fermilab Proton Source machines, constituted by the Pre-Injector, Linac and the synchrotron Booster, have been the workhorse of the Fermi National Accelerator Laboratory (Fermilab). During this time, the High Energy Physics Program has demanded an increase in proton throughput, especially during the past decade with the beginning of the neutrino program at Fermilab. In order to achieve a successful program, major upgrades and changes were made in Booster. Once again, the Proton Source has been charged to double their beam throughput, while maintain the present residual activation levels, to meet the laboratory Intensity Frontier program goals until new machines are built and operational to replace the Proton Source machines. This paper discusses the present performance of Booster and the plans involved in reaching even higher intensities.

  3. Raman forward scattering of high-intensity chirped laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, C.B.; Esarey, E.; Shadwick, B.A.; Leemans, W.P.

    2002-06-23

    Raman forward scattering of a high-intensity, short-duration, frequency-chirped laser pulse propagating in an underdense plasma is examined. The growth of the direct forward scattered light is calculated for a laser pulse with a linear frequency chirp in various spatio-temporal regimes. This includes a previously undescribed regime of strongly-coupled four-wave nonresonant interaction, which is important for relativistic laser intensities. In all regimes of forward scattering, it is shown that the growth rate increases (decreases) for positive (negative) frequency chirp. The effect of chirp on the growth rate is relatively minor, i.e., a few percent chirp yields few percent changes in the growth rates. Relation of these results to recent experiments is discussed.

  4. High intensity ion beams in rf undulator linac

    Directory of Open Access Journals (Sweden)

    E. S. Masunov

    2008-07-01

    Full Text Available The possibility of using a radio frequency undulator field to accelerate a high intensity ion beam in a linac is discussed. Such an accelerator can be realized using the periodical interdigital H-type resonator structure. The accelerating force is produced by an electric field which is a combination of two or more spatial harmonics, none of them being synchronous with the ion beam. The value of this force is proportional to the squared charge. The equations of motion in Hamiltonian form are derived by means of smooth approximation. The analysis of the 3D effective potential function allows finding the conditions of the beam focusing and acceleration. Two ways to increase ion beam intensity are considered: (i to enlarge beam cross section; (ii to neutralize the beam space charge by accelerating ions with opposite charge signs within the same bunch. The basic results are confirmed by a numerical simulation.

  5. Short-pulse high intensity laser thin foil interaction

    Science.gov (United States)

    Audebert, Patrick

    2003-10-01

    The technology of ultrashort pulse laser generation has progressed to the point that optical pulses larger than 10 J, 300 fs duration or shorter are routinely produced. Such pulses can be focused to intensities exceeding 10^18 W/cm^2. With high contrast pulses, these focused intensities can be used to heat solid matter to high temperatures with minimal hydrodynamic expansion, producing an extremely high energy-density state of matter for a short period of time. This high density, high temperature plasma can be studied by x-ray spectroscopy. We have performed experiments on thin foils of different elements under well controlled conditions at the 100 Terawatt laser at LULI to study the characteristics X-ray emission of laser heated solids. To suppress the ASE effect, the laser was frequency doubled. S-polarized light with a peak intensity of 10^19W/cm^2 was used to minimize resonance absorption. To decrease the effect of longitudinal temperature gradients very thin (800 μ) aluminum foil targets were used. We have also studied the effect of radial gradient by limiting the measured x-ray emission zone using 50μ or 100μ pinhole on target. The spectra, in the range 7-8Å, were recorded using a conical crystal spectrometer coupled to a 800 fs resolution streak camera. A Fourier Domain Interferometry (FDI) of the back of the foil was also performed providing a measurement of the hydrodynamic expansion as function of time for each shot. To simulate the experiment, we used the 1D hydrodynamic code FILM with a given set of plasma parameter (ρ, Te) as initial conditions. The X-ray emission was calculated by post processing hydrodynamic results with a collisional-radiative model which uses super-configuration average atomic data. The simulation reproduces the main features of the experimental time resolved spectrum.

  6. The development of a high intensity dance performance fitness test.

    Science.gov (United States)

    Redding, Emma; Weller, Peter; Ehrenberg, Shantel; Irvine, Sarah; Quin, Edel; Rafferty, Sonia; Wyon, Matthew; Cox, Carol

    2009-01-01

    While there is currently a validated dance-specific exercise method of measuring aerobic fitness, no such test has been developed to measure high intensity capabilities in dance. The purpose of this study was to initiate an intermittent high intensity dance-specific fitness test. The test was designed to be able to observe changes in heart rate (HR), thereby allowing for a measurement of physical fitness at high intensities. Sixteen professional dancers (4 males and 12 females) volunteered to take part in this study. The fitness test protocol consists of movements that are representative of contemporary dance, and contains exercise and rest periods that mimic the intermittent nature of dance. The participants performed four trials. The physiological variables measured were HR (b.min(-1)) for each one minute bout of the four minute test for all trials, oxygen uptake (VO(2)) throughout the test, and end blood lactate (BLa mmol.L) for each trial. In addition, five of the participants undertook a maximal oxygen uptake treadmill test, and the scores obtained were compared with those from the dance test. Results show HR consistency across each one minute bout of the test and across each of the four trials of testing for all participants, indicating that the test is reliable. There was good reliability between bouts of each trial (typical error as % of CV = 1.5), intraclass "r" = 0.8, and good reliability between the four trials (typical error as % of CV = 2.1), intraclass "r" = 0.82. There were no significant differences between the maximal VO(2) and BLa scores established in the treadmill and dance tests, demonstrating validity. Thus, the results of this study indicate that the high intensity dance-specific test is a reliable and valid means of assessing and monitoring the cardiovascular fitness of dancers. The test allows dancers to be assessed within an environment that they are accustomed to (the studio), using a mode of exercise that is relevant (dance), and it is

  7. Charcoal reflectance reveals early holocene boreal deciduous forests burned at high intensities.

    Science.gov (United States)

    Hudspith, Victoria A; Belcher, Claire M; Kelly, Ryan; Hu, Feng Sheng

    2015-01-01

    Wildfire size, frequency, and severity are increasing in the Alaskan boreal forest in response to climate warming. One of the potential impacts of this changing fire regime is the alteration of successional trajectories, from black spruce to mixed stands dominated by aspen, a vegetation composition not experienced since the early Holocene. Such changes in vegetation composition may consequently alter the intensity of fires, influencing fire feedbacks to the ecosystem. Paleorecords document past wildfire-vegetation dynamics and as such, are imperative for our understanding of how these ecosystems will respond to future climate warming. For the first time, we have used reflectance measurements of macroscopic charcoal particles (>180μm) from an Alaskan lake-sediment record to estimate ancient charring temperatures (termed pyrolysis intensity). We demonstrate that pyrolysis intensity increased markedly from an interval of birch tundra 11 ky ago (mean 1.52%Ro; 485°C), to the expansion of trees on the landscape ~10.5 ky ago, remaining high to the present (mean 3.54%Ro; 640°C) irrespective of stand composition. Despite differing flammabilities and adaptations to fire, the highest pyrolysis intensities derive from two intervals with distinct vegetation compositions. 1) the expansion of mixed aspen and spruce woodland at 10 cal. kyr BP, and 2) the establishment of black spruce, and the modern boreal forest at 4 cal. kyr BP. Based on our analysis, we infer that predicted expansion of deciduous trees into the boreal forest in the future could lead to high intensity, but low severity fires, potentially moderating future climate-fire feedbacks.

  8. The different effects of high intensity interval training and moderate intensity interval training for weightlessness countermeasures

    Science.gov (United States)

    Wang, Lin-Jie; Cheng, Tan; Zhi-Li, Li; Hui-juan, Wang; Wen-juan, Chen; Jianfeng, Zhang; Desheng, Wang; Dongbin, Niu; Qi, Zhao; Chengjia, Yang; Yanqing, Wang

    High intensity interval training (HIIT) has been demonstrated to improve performance in a relatively short training period. But the difference between high intensity interval training and moderate intensity interval training (MIIT) in simulated weightlessness still has not been well studied. This study sought to characterize the difference between 6 weeks high intensity interval training and moderate intensity interval training under reduced weight (RW) gait training device and zero-gravity locomotion system (ZLS). Twenty-three subjects (14M/4F, 32.5±4.5 years) volunteered to participate. They were divided into three groups, that were MITT (alternating 2 min at 40% VO _{2} peak and 2 min at 60% VO _{2} peak for 30min, five days per week) RW group (n=8), HITT (alternating 2 min at 40% VO _{2} peak and 2 min at 90% VO _{2} peak for 30min, three days per week) RW group (n=8) and HITT ZLS group (n=7). The Z-axis load used in RW group was 80% body weight (BW) and in ZLS was 100% BW. Cardiopulmonary function was measured before, after 4-week training and after 6-week training. Isokinetic knee extension-flexion test at 60(°) deg/s and 180(°) deg/s were performed before and after the 6-week training, and isometric knee extension-flexion test at 180(°) deg/s was also examined at the same time. It was found that the VO _{2} peaks, metabolic equivalent (MET), Speedmax and respiratory exchange ratio (RER) were significantly increased after 4 and 6-week training in all three groups and no significant group difference were detected. The peak torque at 60(°) deg/s for right knee flexion were significantly increased after 6 week-training in all three groups, and only in HITT RW group the total power at 60(°) deg/s for right knee flexion enhanced. The total power and average power at 60(°) deg/s for right knee extension decreased significantly after 6-week training in all three groups. The peak torque at 60(°) deg/s for right knee extension in MIIT RW group was

  9. High Performance Human Face Recognition using Independent High Intensity Gabor Wavelet Responses: A Statistical Approach

    CERN Document Server

    Kar, Arindam; Basu, Dipak Kumar; Nasipuri, Mita; Kundu, Mahantapas

    2011-01-01

    In this paper, we present a technique by which high-intensity feature vectors extracted from the Gabor wavelet transformation of frontal face images, is combined together with Independent Component Analysis (ICA) for enhanced face recognition. Firstly, the high-intensity feature vectors are automatically extracted using the local characteristics of each individual face from the Gabor transformed images. Then ICA is applied on these locally extracted high-intensity feature vectors of the facial images to obtain the independent high intensity feature (IHIF) vectors. These IHIF forms the basis of the work. Finally, the image classification is done using these IHIF vectors, which are considered as representatives of the images. The importance behind implementing ICA along with the high-intensity features of Gabor wavelet transformation is twofold. On the one hand, selecting peaks of the Gabor transformed face images exhibit strong characteristics of spatial locality, scale, and orientation selectivity. Thus these...

  10. The effect of progressive high-intensity inspiratory muscle training and fixed high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients

    OpenAIRE

    Jung, Ju-hyeon; Kim, Nan-soo

    2015-01-01

    [Purpose] This study investigated the effects of progressive load and fixed load high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients. [Subjects] Twenty-one stroke patients were assigned to one of three groups: progressive load high-intensity inspiratory muscle training (n = 8), fixed load high-intensity inspiratory muscle training (n = 6), and controls (n = 7). [Methods] The progressive load and fixed load high-intensity inspiratory muscle tra...

  11. Examination of Beryllium Under Intense High Energy Proton Beam at CERN's HiRadMat Facility

    CERN Document Server

    Ammigan, K; Hurh, P; Zwaska, R; Atherton, A; Caretta, O; Davenne, t; Densham, C; Fitton, M; Loveridge, P; O'Dell, J; Roberts, S; Kuksenko, v; Butcher, M; Calviani, M; Guinchard, M; Losito, R

    2015-01-01

    Beryllium is extensively used in various accelerator beam lines and target facilities as material for beam win- dows, and to a lesser extent, as secondary particle produc- tion targets. With increasing beam intensities of future ac- celerator facilities, it is critical to understand the response of beryllium under extreme conditions to avoid compro- mising particle production efficiency by limiting beam pa- rameters. As a result, the planned experiment at CERN’s HiRadMat facility will take advantage of the test facility’s tunable high intensity proton beam to probe and investigate the damage mechanisms of several grades of beryllium. The test matrix will consist of multiple arrays of thin discs of varying thicknesses as well as cylinders, each exposed to increasing beam intensities. Online instrumentations will acquire real time temperature, strain, and vibration data of the cylinders, while Post-Irradiation-Examination (PIE) of the discs will exploit advanced microstructural characteri- zation and imagin...

  12. Examination of Beryllium Under Intense High Energy Proton Beam at CERN's HiRadMat Facility

    CERN Document Server

    Ammigan, K.; Hurh, P.; Zwaska, R.; Atherton, A.; Caretta, O.; Davenne,T.; Densham, C.; Fitton, M.; Loveridge, P.; O'Dell, J.; Roberts, S.; Kuksenko, V.; Butcher, M.; Calviani, M.; Guinchard, M.; Losito, R.

    2017-01-01

    Beryllium is extensively used in various accelerator beam lines and target facilities as material for beam win- dows, and to a lesser extent, as secondary particle produc- tion targets. With increasing beam intensities of future ac- celerator facilities, it is critical to understand the response of beryllium under extreme conditions to avoid compro- mising particle production efficiency by limiting beam pa- rameters. As a result, the planned experiment at CERN’s HiRadMat facility will take advantage of the test facility’s tunable high intensity proton beam to probe and investigate the damage mechanisms of several grades of beryllium. The test matrix will consist of multiple arrays of thin discs of varying thicknesses as well as cylinders, each exposed to increasing beam intensities. Online instrumentations will acquire real time temperature, strain, and vibration data of the cylinders, while Post-Irradiation-Examination (PIE) of the discs will exploit advanced microstructural characteri- zation and imagin...

  13. Effects of intensity and duration in aerobic high-intensity interval training in highly trained junior cross-country skiers.

    Science.gov (United States)

    Sandbakk, Øyvind; Sandbakk, Silvana B; Ettema, Gertjan; Welde, Boye

    2013-07-01

    The purpose of this study was to test whether a long duration of aerobic high-intensity interval training is more effective than shorter intervals at a higher intensity in highly trained endurance athletes. The sample comprised of 12 male and 9 female, national-level, junior cross-country skiers (age, 17.5 ± 0.4 years, maximal oxygen uptake (V[Combining Dot Above]O2max): 67.4 ± 7.7 ml min kg), who performed 8-week baseline and 8-week intervention training periods on dry land. During the intervention period, a short-interval group (SIG, n = 7) added 2 weekly sessions with short duration intervals (2- to 4-minute bouts, total duration of 15-20 minutes), a long-interval group (LIG; n = 7) added 2 weekly sessions with long duration intervals (5- to 10-minute bouts, total duration of 40-45 minutes). The interval sessions were performed with the athletes' maximal sustainable intensity. A control group (CG; n = 7) added 2 weekly sessions with low-intensity endurance training at 65-74% of maximal heart rate. Before and after the intervention period, the skiers were tested for time-trial performance on 12-km roller-ski skating and 7-km hill run. V[Combining Dot Above]O2max and oxygen uptake at the ventilatory threshold (V[Combining Dot Above]O2VT) were measured during treadmill running. After the intervention training period, the LIG-improved 12-km roller ski, 7-km hill run, V[Combining Dot Above]O2max, and V[Combining Dot Above]O2VT by 6.8 ± 4.0%, 4.8 ± 2.6%, 3.7 ± 1.6%, and 5.8 ± 3.3%, respectively, from pre- to posttesting, and improved both performance tests and V[Combining Dot Above]O2VT when compared with the SIG and the CG (all p < 0.05). The SIG improved V[Combining Dot Above]O2max by 3.5 ± 3.2% from pre- to posttesting (p < 0.05), whereas the CG remained unchanged. As hypothesized, a long duration of aerobic high-intensity interval training improved endurance performance and oxygen uptake at the ventilatory threshold more than shorter intervals at a higher

  14. Extremely high-intensity laser interactions with fundamental quantum systems

    CERN Document Server

    Di Piazza, A; Hatsagortsyan, K Z; Keitel, C H

    2011-01-01

    The field of laser-matter interaction traditionally deals with the response of atoms, molecules and plasmas to an external light wave. However, the recent sustained technological progress is opening the possibility of employing intense laser radiation to prompt or substantially influence physical processes beyond atomic-physics energy scales. Available optical laser intensities exceeding $10^{22}\\;\\text{W/cm$^2$}$ can push the fundamental light-electron interaction to the extreme limit where radiation-reaction effects dominate the electron dynamics, can shed light on the structure of the quantum vacuum and can prime the creation of particles like electrons, muons and pions and the corresponding antiparticles. Also, novel sources of intense coherent high-energy photons and laser-based particle colliders can pave the way to nuclear quantum optics and can even allow for potential discovery of new particles beyond the Standard Model. These are the main topics of the present article, which is devoted to a review o...

  15. Transverse Beam Halo Measurements at High Intensity Neutrino Source (HINS) using Vibrating Wire Monitor

    Energy Technology Data Exchange (ETDEWEB)

    Chung, M.; Hanna, B.; Scarpine, V.; Shiltsev, V.; Steimel, J.; Artinian, S.; Arutunian, S.

    2015-02-26

    The measurement and control of beam halos will be critical for the applications of future high-intensity hadron linacs. In particular, beam profile monitors require a very high dynamic range when used for the transverse beam halo measurements. In this study, the Vibrating Wire Monitor (VWM) with aperture 60 mm was installed at the High Intensity Neutrino Source (HINS) front-end to measure the transverse beam halo. A vibrating wire is excited at its resonance frequency with the help of a magnetic feedback loop, and the vibrating and sensitive wires are connected through a balanced arm. The sensitive wire is moved into the beam halo region by a stepper motor controlled translational stage. We study the feasibility of the vibrating wire for the transverse beam halo measurements in the low-energy front-end of the proton linac.

  16. The effect of high and low exercise intensity periods on a simple memory recognition test

    Institute of Scientific and Technical Information of China (English)

    Ben Rattray; Disa J. Smee

    2016-01-01

    Purpose: The purpose of this study was to investigate the effect of variable intensities on a simple memory recognition task during exercise. Methods: Twenty active participants took part in initial testing, a familiarization trial and then four 60 min cycling interventions in a randomized order. Interventions consisted of no exercise (control), constant exercise at 90%ventilatory threshold (constant) and 2 trials that initially mimicked the constant trial, but then included periods of high (∼90%VO2peak) and low intensities (∼50%VO2peak). Cardiorespiratory measures and capillary blood samples were taken throughout. A short tablet-based cognitive task was completed prior to and during (50 and 55 min into exercise) each intervention. Results: The exercise conditions facilitated response time (p=0.009), although the extent of this effect was not as strong in the variable exercise conditions (p = 0.011–0.089). High intensity exercise periods resulted in some cognitive regression back towards control trial performance. Elevations in cardiorespiratory measures and periods of hypocapnia could not explain changes in cognitive performance. Conclusion: Changes in cognitive performance with variations in exercise intensity are likely to have implications for sport and occupational settings. The timing of cognitive tests to exercise intensity changes as well as use of short cognitive assessments will be important for future work.

  17. High energy physics, past, present and future

    Science.gov (United States)

    Sugawara, Hirotaka

    2017-03-01

    At the beginning of last century we witnessed the emergence of new physics, quantum theory and gravitational theory, which gave us correct understanding of the world of atoms and deep insight into the structure of universe we live in. Towards the end of the century, string theory emerged as the most promising candidate to unify these two theories. In this talk, I would like to assert that the understanding of the origin of physical constants, ℏ (Planck constant) for quantum theory, and G (Newton’s gravitational constant) for gravitational theory within the framework of string theory is the key to understanding string theory. Then, I will shift to experimental high energy physics and discuss the necessity of world-wide collaboration in the area of superconducting technology which is essential in constructing the 100 TeV hadron collider.

  18. Diamond sensors for future high energy experiments

    Energy Technology Data Exchange (ETDEWEB)

    Bachmair, Felix, E-mail: bachmair@phys.ethz.ch

    2016-09-21

    With the planned upgrade of the LHC to High-Luminosity-LHC [1], the general purpose experiments ATLAS and CMS are planning to upgrade their innermost tracking layers with more radiation tolerant technologies. Chemical Vapor Deposition CVD diamond is one such technology. CVD diamond sensors are an established technology as beam condition monitors in the highest radiation areas of all LHC experiments. The RD42-collaboration at CERN is leading the effort to use CVD diamond as a material for tracking detectors operating in extreme radiation environments. An overview of the latest developments from RD42 is presented including the present status of diamond sensor production, a study of pulse height dependencies on incident particle flux and the development of 3D diamond sensors.

  19. Diamond sensors for future high energy experiments

    Science.gov (United States)

    Bachmair, Felix

    2016-09-01

    With the planned upgrade of the LHC to High-Luminosity-LHC [1], the general purpose experiments ATLAS and CMS are planning to upgrade their innermost tracking layers with more radiation tolerant technologies. Chemical Vapor Deposition CVD diamond is one such technology. CVD diamond sensors are an established technology as beam condition monitors in the highest radiation areas of all LHC experiments. The RD42-collaboration at CERN is leading the effort to use CVD diamond as a material for tracking detectors operating in extreme radiation environments. An overview of the latest developments from RD42 is presented including the present status of diamond sensor production, a study of pulse height dependencies on incident particle flux and the development of 3D diamond sensors.

  20. Electron cloud instability in high intensity proton rings

    Directory of Open Access Journals (Sweden)

    K. Ohmi

    2002-11-01

    Full Text Available An e^{-}p instability has been observed in some proton rings. The instability, which causes beam loss, limits the performance of the ring. The instability may be serious for 3 and 50 GeV proton storage rings in the Japan Proton Accelerator Research Complex (J-PARC. We study the e^{-}p instability in several high intensity proton storage rings operated in the world. This work informs J-PARC of the necessity to cure the instability, for example, by applying a TiN coating on the chamber surface.

  1. High Intensity Focused Ultrasound Tumor Therapy System and Its Application

    Science.gov (United States)

    Sun, Fucheng; He, Ye; Li, Rui

    2007-05-01

    At the end of last century, a High Intensity Focused Ultrasound (HIFU) tumor therapy system was successfully developed and manufactured in China, which has been already applied to clinical therapy. This article aims to discuss the HIFU therapy system and its application. Detailed research includes the following: power amplifiers for high-power ultrasound, ultrasound transducers with large apertures, accurate 3-D mechanical drives, a software control system (both high-voltage control and low-voltage control), and the B-mode ultrasonic diagnostic equipment used for treatment monitoring. Research on the dosage of ultrasound required for tumour therapy in multiple human cases has made it possible to relate a dosage formula, presented in this paper, to other significant parameters such as the volume of thermal tumor solidification, the acoustic intensity (I), and the ultrasound emission time (tn). Moreover, the HIFU therapy system can be applied to the clinical treatment of both benign and malignant tumors in the pelvic and abdominal cavity, such as uterine fibroids, liver cancer and pancreatic carcinoma.

  2. High-Intensity Interval Training Elicits Higher Enjoyment than Moderate Intensity Continuous Exercise.

    Science.gov (United States)

    Thum, Jacob S; Parsons, Gregory; Whittle, Taylor; Astorino, Todd A

    2017-01-01

    Exercise adherence is affected by factors including perceptions of enjoyment, time availability, and intrinsic motivation. Approximately 50% of individuals withdraw from an exercise program within the first 6 mo of initiation, citing lack of time as a main influence. Time efficient exercise such as high intensity interval training (HIIT) may provide an alternative to moderate intensity continuous exercise (MICT) to elicit substantial health benefits. This study examined differences in enjoyment, affect, and perceived exertion between MICT and HIIT. Twelve recreationally active men and women (age = 29.5 ± 10.7 yr, VO2max = 41.4 ± 4.1 mL/kg/min, BMI = 23.1 ± 2.1 kg/m2) initially performed a VO2max test on a cycle ergometer to determine appropriate workloads for subsequent exercise bouts. Each subject returned for two additional exercise trials, performing either HIIT (eight 1 min bouts of cycling at 85% maximal workload (Wmax) with 1 min of active recovery between bouts) or MICT (20 min of cycling at 45% Wmax) in randomized order. During exercise, rating of perceived exertion (RPE), affect, and blood lactate concentration (BLa) were measured. Additionally, the Physical Activity Enjoyment Scale (PACES) was completed after exercise. Results showed higher enjoyment (p = 0.013) in response to HIIT (103.8 ± 9.4) versus MICT (84.2 ± 19.1). Eleven of 12 participants (92%) preferred HIIT to MICT. However, affect was lower (pHIIT versus MICT. Although HIIT is more physically demanding than MICT, individuals report greater enjoyment due to its time efficiency and constantly changing stimulus.

  3. High-Intensity Sweeteners in Alternative Tobacco Products.

    Science.gov (United States)

    Miao, Shida; Beach, Evan S; Sommer, Toby J; Zimmerman, Julie B; Jordt, Sven-Eric

    2016-11-01

    Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objective of the present study was to quantify added sweeteners in smokeless tobacco products, a dissolvable product, electronic cigarette liquids and to compare with sweetener levels in confectionary products. Sweetener content of US-sourced smokeless tobacco, electronic cigarette liquid, and confectionary product samples was analyzed by liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). All smokeless products contained synthetic high intensity sweeteners, with snus and dissolvables exceeding levels in confectionary products (as much as 25-fold). All snus samples contained sucralose and most also aspartame, but no saccharin. In contrast, all moist snuff samples contained saccharin. The dissolvable sample contained sucralose and sorbitol. Ethyl maltol was the most common sweet-associated component in electronic cigarette liquids. Sweetener content was dependent on product category, with saccharin in moist snuff, an older category, sucralose added at high levels to more recently introduced products (snus, dissolvable) and ethyl maltol in electronic cigarette liquid. The very high sweetener concentrations may be necessary for the consumer to tolerate the otherwise aversive flavors of tobacco ingredients. Regulation of sweetener levels in smokeless tobacco products may be an effective measure to modify product attractiveness, initiation and use patterns. Dissolvables, snus and electronic cigarettes have been promoted as risk-mitigation products due to their relatively low content of nitrosamines and other tobacco toxicants. This study is the first to quantify high

  4. High-Intensity Sweeteners in Alternative Tobacco Products

    Science.gov (United States)

    Miao, Shida; Beach, Evan S.; Sommer, Toby J.; Zimmerman, Julie B.

    2016-01-01

    Introduction: Sweeteners in tobacco products may influence use initiation and reinforcement, with special appeal to adolescents. Recent analytical studies of smokeless tobacco products (snuff, snus, dissolvables) detected flavorants identical to those added to confectionary products such as hard candy and chewing gum. However, these studies did not determine the levels of sweeteners. The objective of the present study was to quantify added sweeteners in smokeless tobacco products, a dissolvable product, electronic cigarette liquids and to compare with sweetener levels in confectionary products. Methods: Sweetener content of US-sourced smokeless tobacco, electronic cigarette liquid, and confectionary product samples was analyzed by liquid chromatography-electrospray ionization–mass spectrometry (LC-ESI-MS). Results: All smokeless products contained synthetic high intensity sweeteners, with snus and dissolvables exceeding levels in confectionary products (as much as 25-fold). All snus samples contained sucralose and most also aspartame, but no saccharin. In contrast, all moist snuff samples contained saccharin. The dissolvable sample contained sucralose and sorbitol. Ethyl maltol was the most common sweet-associated component in electronic cigarette liquids. Discussion: Sweetener content was dependent on product category, with saccharin in moist snuff, an older category, sucralose added at high levels to more recently introduced products (snus, dissolvable) and ethyl maltol in electronic cigarette liquid. The very high sweetener concentrations may be necessary for the consumer to tolerate the otherwise aversive flavors of tobacco ingredients. Regulation of sweetener levels in smokeless tobacco products may be an effective measure to modify product attractiveness, initiation and use patterns. Implications: Dissolvables, snus and electronic cigarettes have been promoted as risk-mitigation products due to their relatively low content of nitrosamines and other tobacco

  5. On the GCR intensity and the inversion of the heliospheric magnetic field during the periods of the high solar activity

    CERN Document Server

    Krainev, M B

    2014-01-01

    We consider the long-term behavior of the solar and heliospheric parameters and the GCR intensity in the periods of high solar activity and the inversions of heliospheric magnetic field (HMF). The classification of the HMF polarity structures and the meaning of the HMF inversion are discussed. The procedure is considered how to use the known HMF polarity distribution for the GCR intensity modeling during the periods of high solar activity. We also briefly discuss the development and the nearest future of the sunspot activity and the GCR intensity in the current unusual solar cycle 24.

  6. Longitudinal tracking studies for a high intensity proton synchrotron

    Energy Technology Data Exchange (ETDEWEB)

    Lessner, E.; Cho, Y.; Harkay, K.; Symon, K. [Argonne National Laboratory, 9700 Cass Ave., Argonne, Illinois 60439 (United States)

    1996-06-01

    Results from longitudinal tracking studies for a high intensity proton synchrotron designed for a 1-MW spallation source are presented. The machine delivers a proton beam of 0.5 mA time-averaged current at a repetition rate of 30 Hz. The accelerator is designed to have radiation levels that allow hands-on-maintenance. However, the high beam intensity causes strong space charge fields whose effects may lead to particle loss and longitudinal instabilities. The space charge fields modify the particle distribution, distort the stable bucket area and reduce the rf linear restoring force. Tracking simulations were conducted to analyze the space charge effects on the dynamics of the injection and acceleration processes and means to circumvent them. The tracking studies led to the establishment of the injected beam parameters and rf voltage program that minimized beam loss and longitudinal instabilities. Similar studies for a 10-GeV synchrotron that uses the 2-GeV synchrotron as its injector are also discussed. {copyright} {ital 1996 American Institute of Physics.}

  7. Formation of a high intensity low energy positron string

    Science.gov (United States)

    Donets, E. D.; Donets, E. E.; Syresin, E. M.; Itahashi, T.; Dubinov, A. E.

    2004-05-01

    The possibility of a high intensity low energy positron beam production is discussed. The proposed Positron String Trap (PST) is based on the principles and technology of the Electron String Ion Source (ESIS) developed in JINR during the last decade. A linear version of ESIS has been used successfully for the production of intense highly charged ion beams of various elements. Now the Tubular Electron String Ion Source (TESIS) concept is under study and this opens really new promising possibilities in physics and technology. In this report, we discuss the application of the tubular-type trap for the storage of positrons cooled to the cryogenic temperatures of 0.05 meV. It is intended that the positron flux at the energy of 1-5 eV, produced by the external source, is injected into the Tubular Positron Trap which has a similar construction as the TESIS. Then the low energy positrons are captured in the PST Penning trap and are cooled down because of their synchrotron radiation in the strong (5-10 T) applied magnetic field. It is expected that the proposed PST should permit storing and cooling to cryogenic temperature of up to 5×109 positrons. The accumulated cooled positrons can be used further for various physics applications, for example, antihydrogen production.

  8. Use of High Intensity Focused Ultrasound for Treating Malignant Tumors

    Institute of Scientific and Technical Information of China (English)

    WenzhiChen; ZhibiaoWang; FengWu; JinBai; HuiZhu; JianzhongZou; KequanLi; FanglinXie; ZhilongWang

    2004-01-01

    OBJECTIVE To investigate the efficacy and side effects of high intensity focused ultrasound(HIFU) in the treatment of malignant solid tumors. METHODS Thirty patients who refused surgery and/or were refractory to chemotherapy were treated by HIFU alone, with the efficacy and side effects monitored as follows: observation of vital organ signs; functional assay of important organs; imaging examinations including: digital subtraction angiography (DSA), CT, MRI, single photon emission computed tomography (SPECT), large core needle biopsy, complications and metastasis. RESULTS After HIFU therapy, the vital signs remained stable and the functions of the heart, lung, kidney and liver were also normal. DSA images showed that small or larger arteries were not damaged. After a follow-up of 10-38 months(mean 23.1 months), 26 patients(87%) were alive. The volume of the tumor underwent complete regression in 10 patients. Shrinkage of the tumor volume ≥50% was observed in 13 patients. Eight of 13 patients were examined by large core needle biopsy, all showing necrosis and/or fibrosis though 3 patients(10%) had local recurrence. Two of these were retreated again by HIFU and the locally recurrent tumors were controlled. New metastases developed in 5 patients after H IFU. Two patients suffered from peripheral nerve injuriy and they have recovered during the follow-up. One patient developed skin injury. CONCLUSION High intensity focused ultrasound is effective and safe in the treatment of malignant solid tumors.

  9. Efficacy of high intensity atorvastatin versus moderate intensity atorvastatin for acute coronary syndrome patients with diabetes mellitus.

    Science.gov (United States)

    Liu, Zhi; Xu, Yueqiao; Hao, Hengjian; Yin, Chunlin; Xu, Ji; Li, Jing; Wang, Yanling; Xu, Dong

    2016-11-01

    To investigate whether more benefits can be achieved through high intensity atorvastatin compared with moderate intensity atorvastatin in acute coronary syndrome (ACS) patients with diabetes mellitus (DM). This was a randomized controlled trail. Total 591 ACS patients with DM who underwent percutaneous coronary intervention were enrolled, 297 in high intensity atorvastatin group (40mg/day) and 294 in moderate intensity atorvastatin group (20mg/day). The primary end point was one-year incidence of major adverse cardiovascular events (MACE, including cardiovascular death, spontaneous myocardial infarction, unplanned revascularization). Cox proportional hazard regression models were used to analyze the association between clinical endpoints and atorvastatin treatment. At the end of one-year, low-density lipoprotein cholesterol level was lower in high intensity group than in moderate group (1.6±0.6 vs 1.8±0.6, p=0.041). MACE in high intensity group decreased 44.5% than moderate group (8.4% vs. 14.6%, p=0.018). The adjusted hazard ratio (HR) for MACE in patients with atorvastatin 40mg/d was lower compared to patients with atorvastatin 20mg/d (HR [95% CI] 0.61 [0.36 to 0.91], p=0.026). The rates of adverse events were no significantly different between the two groups. For ACS patients with DM, high intensity atorvastatin induced better long-term outcomes compared with moderate intensity. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Ultra-High Intensity Magnetic Field Generation in Dense Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Fisch, Nathaniel J. [Princeton Univ., NJ (United States)

    2014-01-08

    The main objective of this grant proposal was to explore the efficient generation of intense currents. Whereas the efficient generation of electric current in low-­energy-­density plasma has occupied the attention of the magnetic fusion community for several decades, scant attention has been paid to carrying over to high-­energy-­density plasma the ideas for steady-­state current drive developed for low-­energy-­density plasma, or, for that matter, to inventing new methodologies for generating electric current in high-­energy-­density plasma. What we proposed to do was to identify new mechanisms to accomplish current generation, and to assess the operation, physics, and engineering basis of new forms of current drive in regimes appropriate for new fusion concepts.

  11. Increased collection efficiency of LIFI high intensity electrodeless light source

    Science.gov (United States)

    Hafidi, Abdeslam; DeVincentis, Marc; Duelli, Markus; Gilliard, Richard

    2008-02-01

    Recently, RF driven electrodeless high intensity light sources have been implemented successfully in the projection display systems for HDTV and videowall applications. This paper presents advances made in the RF waveguide and electric field concentrator structures with the purpose of reducing effective arc size and increasing light collection. In addition, new optical designs are described that further improve system efficiency. The results of this work demonstrate that projection system light throughput is increased relative to previous implementations and performance is optimized for home theater and other front projector applications that maintain multi-year lifetime without re-lamping, complete spectral range, fast start times and high levels of dynamic contrast due to dimming flexibility in the light source system.

  12. Generation And Measurement Of High Contrast Ultrashort Intense Laser Pulses

    CERN Document Server

    Konoplev, O A

    2000-01-01

    In this thesis, the generation and measurement of high contrast, intense, ultrashort pulses have been studied. Various factors affecting the contrast and pulse shape of ultrashort light pulses from a chirped pulse amplification (CPA) laser system are identified. The level of contrast resulting from influence of these factors is estimated. Methods for improving and controlling the pulse shape and increasing the contrast are discussed. Ultrahigh contrast, 1-ps pulses were generated from a CPA system with no temporal structure up to eleven orders of magnitude. This is eight orders of magnitude higher contrast than the original pulse. This contrast boost was achieved using two techniques. One is the optical pulse cleaning based on the nonlinear birefringence of the chirping fiber and applied to the pulses before amplification. The other is the fast saturable absorber. The fast saturable absorber was placed after amplification and compression of the pulse. The measurements of high-contrast, ultrashort pulse with h...

  13. Ultra-High Intensity Magnetic Field Generation in Dense Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Fisch, Nathaniel J

    2014-01-08

    I. Grant Objective The main objective of this grant proposal was to explore the efficient generation of intense currents. Whereasthefficient generation of electric current in low-­energy-­density plasma has occupied the attention of the magnetic fusion community for several decades, scant attention has been paid to carrying over to high-­energy-­density plasma the ideas for steady-­state current drive developed for low-­energy-­density plasma, or, for that matter, to inventing new methodologies for generating electric current in high-­energy-­density plasma. What we proposed to do was to identify new mechanisms to accomplish current generation, and to assess the operation, physics, and engineering basis of new forms of current drive in regimes appropriate for new fusion concepts.

  14. COLLIMATORS AND MATERIALS FOR HIGH INTENSITY HEAVY ION SYNCHROTRONS

    CERN Document Server

    Stadlmann, J; Kollmus, H; Spiller, P; Strasik, I; Tahir, N A; Tomut, M; Trautmann, C

    2012-01-01

    The operation of high power high brightness accelerators requires huge efforts for beam cleaning and machine protection. Within the WP 8 (ColMat) of the EU research framework EuCARD[1] we investigate new materials and methods for beam collimation and machine protection. We present an overview of these activities at the GSI Helmholtzzentrum f¨ur Schwerionenforschung, Darmstadt. Simulations of accidental beam losses in LHC and SIS100 have been performed. Scenarios for halo collimation of heavy ions and protons in SIS100 routine operation have been investigated. A prototype of a cryogenic collimator for charge exchange losses during intermediate charge state heavy ion operation in SIS100 has been build and tested with beam. Several candidates of advanced composite materials for collimation system upgrades of present and future high power accelerators have been irradiated and their properties are being characterized. Most deliverables and milestones of the R&D programme were already reached before the end of...

  15. Benchmark of Space Charge Simulations and Comparison with Experimental Results for High Intensity, Low Energy Accelerators

    CERN Document Server

    Cousineau, Sarah M

    2005-01-01

    Space charge effects are a major contributor to beam halo and emittance growth leading to beam loss in high intensity, low energy accelerators. As future accelerators strive towards unprecedented levels of beam intensity and beam loss control, a more comprehensive understanding of space charge effects is required. A wealth of simulation tools have been developed for modeling beams in linacs and rings, and with the growing availability of high-speed computing systems, computationally expensive problems that were inconceivable a decade ago are now being handled with relative ease. This has opened the field for realistic simulations of space charge effects, including detailed benchmarks with experimental data. A great deal of effort is being focused in this direction, and several recent benchmark studies have produced remarkably successful results. This paper reviews the achievements in space charge benchmarking in the last few years, and discusses the challenges that remain.

  16. Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Kristie L.; Wang, Anbo; Pickrell, Gary R.

    2006-11-14

    This report summarizes technical progress during the program “Optical Fiber High Temperature Sensor Instrumentation for Energy Intensive Industries”, performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The objective of this program was to use technology recently invented at Virginia Tech to develop and demonstrate the application of self-calibrating optical fiber temperature and pressure sensors to several key energy-intensive industries where conventional, commercially available sensors exhibit greatly abbreviated lifetimes due primarily to environmental degradation. A number of significant technologies were developed under this program, including • a laser bonded silica high temperature fiber sensor with a high temperature capability up to 700°C and a frequency response up to 150 kHz, • the world’s smallest fiber Fabry-Perot high temperature pressure sensor (125 x 20 μm) with 700°C capability, • UV-induced intrinsic Fabry-Perot interferometric sensors for distributed measurement, • a single crystal sapphire fiber-based sensor with a temperature capability up to 1600°C. These technologies have been well demonstrated and laboratory tested. Our work plan included conducting major field tests of these technologies at EPRI, Corning, Pratt & Whitney, and Global Energy; field validation of the technology is critical to ensuring its usefulness to U.S. industries. Unfortunately, due to budget cuts, DOE was unable to follow through with its funding commitment to support Energy Efficiency Science Initiative projects and this final phase was eliminated.

  17. Relativistic electron mirrors from high intensity laser nanofoil interactions

    Energy Technology Data Exchange (ETDEWEB)

    Kiefer, Daniel

    2012-12-21

    The reflection of a laser pulse from a mirror moving close to the speed of light could in principle create an X-ray pulse with unprecedented high brightness owing to the increase in photon energy and accompanying temporal compression by a factor of 4γ{sup 2}, where γ is the Lorentz factor of the mirror. While this scheme is theoretically intriguingly simple and was first discussed by A. Einstein more than a century ago, the generation of a relativistic structure which acts as a mirror is demanding in many different aspects. Recently, the interaction of a high intensity laser pulse with a nanometer thin foil has raised great interest as it promises the creation of a dense, attosecond short, relativistic electron bunch capable of forming a mirror structure that scatters counter-propagating light coherently and shifts its frequency to higher photon energies. However, so far, this novel concept has been discussed only in theoretical studies using highly idealized interaction parameters. This thesis investigates the generation of a relativistic electron mirror from a nanometer foil with current state-of-the-art high intensity laser pulses and demonstrates for the first time the reflection from those structures in an experiment. To achieve this result, the electron acceleration from high intensity laser nanometer foil interactions was studied in a series of experiments using three inherently different high power laser systems and free-standing foils as thin as 3nm. A drastic increase in the electron energies was observed when reducing the target thickness from the micrometer to the nanometer scale. Quasi-monoenergetic electron beams were measured for the first time from ultrathin (≤5nm) foils, reaching energies up to ∝35MeV. The acceleration process was studied in simulations well-adapted to the experiments, indicating the transition from plasma to free electron dynamics as the target thickness is reduced to the few nanometer range. The experience gained from those

  18. Application of High Intensity THz Pulses for Gas High Harmonic Generation

    CERN Document Server

    Balogh, Emeric; Hebling, János; Dombi, Péter; Farkas, Győző; Varjú, Katalin

    2013-01-01

    The main effects of an intense THz pulse on gas high harmonic generation are studied via trajectory analysis on the single atom level. Spectral and temporal modifications to the generated radiation are highlighted.

  19. Plasma Irisin Modestly Increases during Moderate and High-Intensity Afternoon Exercise in Obese Females

    Science.gov (United States)

    Winn, Nathan C.; Grunewald, Zachary I.; Liu, Ying; Heden, Timothy D.; Nyhoff, Lauren M.; Kanaley, Jill A.

    2017-01-01

    Background and Purpose Irisin is an exercise-responsive myokine that has been proposed to exert anti-obesity benefits; yet its response during exercise in obese women is not described. This study characterized plasma irisin levels during a single bout of afternoon isocaloric-exercise of different intensities (moderate- vs high-intensity) in obese females. Methods Eleven obese females participated in 3 randomized study days beginning at 1600h: 1) no exercise (NoEx), 2) moderate exercise (ModEx; 55%VO2max) and 3) high intensity interval exercise (IntEx; 4 min (80%VO2max)/3 min (50% VO2max). Frequent blood samples were analyzed for glucose and lactate (whole-blood), and insulin, c-peptide, glucagon, and irisin (plasma) throughout 190 min of testing. Results Plasma irisin increased above baseline during ModEx and IntEx (P0.05). Peak irisin levels during ModEx and IntEx exercise were 11.9± 3.4% and 12.3 ± 4.1% relative to baseline (Pexercise intensities (P>0.05). Irisin levels remained elevated above resting for 125 minutes post-exercise during ModEx, whereas levels returned to baseline within 15 minutes post-exercise during IntEx. Similarly, no associations were found between plasma irisin levels and circulating lactate, glucose, insulin, c-peptide, or glucagon among study days (P>0.05). However, there was an inverse association between basal irisin and lean mass (r = -0.70, P = 0.01). Conclusion A single bout of moderate and high intensity afternoon exercise induces modest increases in circulating irisin concentrations during exercise; however the regulation post-exercise appears to be dimorphic between exercise intensity in obese females. Future studies are needed to compare morning and afternoon exercise on irisin secretion. PMID:28125733

  20. Semicircular Canal Pressure Changes During High-intensity Acoustic Stimulation.

    Science.gov (United States)

    Maxwell, Anne K; Banakis Hartl, Renee M; Greene, Nathaniel T; Benichoux, Victor; Mattingly, Jameson K; Cass, Stephen P; Tollin, Daniel J

    2017-08-01

    Acoustic stimulation generates measurable sound pressure levels in the semicircular canals. High-intensity acoustic stimuli can cause hearing loss and balance disruptions. To examine the propagation of acoustic stimuli to the vestibular end-organs, we simultaneously measured fluid pressure in the cochlea and semicircular canals during both air- and bone-conducted sound presentation. Five full-cephalic human cadaveric heads were prepared bilaterally with a mastoidectomy and extended facial recess. Vestibular pressures were measured within the superior, lateral, and posterior semicircular canals, and referenced to intracochlear pressure within the scala vestibuli with fiber-optic pressure probes. Pressures were measured concurrently with laser Doppler vibrometry measurements of stapes velocity during stimulation with both air- and bone-conduction. Stimuli were pure tones between 100 Hz and 14 kHz presented with custom closed-field loudspeakers for air-conducted sounds and via commercially available bone-anchored device for bone-conducted sounds. Pressures recorded in the superior, lateral, and posterior semicircular canals in response to sound stimulation were equal to or greater in magnitude than those recorded in the scala vestibuli (up to 20 dB higher). The pressure magnitudes varied across canals in a frequency-dependent manner. High sound pressure levels were recorded in the semicircular canals with sound stimulation, suggesting that similar acoustical energy is transmitted to the semicircular canals and the cochlea. Since these intralabyrinthine pressures exceed intracochlear pressure levels, our results suggest that the vestibular end-organs may also be at risk for injury during exposure to high-intensity acoustic stimuli known to cause trauma in the auditory system.

  1. Future hurricane storm surge risk for the U.S. gulf and Florida coasts based on projections of thermodynamic potential intensity

    Energy Technology Data Exchange (ETDEWEB)

    Balaguru, Karthik; Judi, David R.; Leung, L. Ruby

    2016-06-23

    Coastal populations in the global tropics and sub-tropics are vulnerable to the devastating impacts of hurricane storm surge and this risk is only expected to rise under climate change. In this study, we address this issue for the U.S. Gulf and Florida coasts. Using the framework of Potential Intensity, observations and output from coupled climate models, we show that the future large-scale thermodynamic environment may become more favorable for hurricane intensification. Under the RCP 4.5 emissions scenario and for the peak hurricane season months of August–October, we show that the mean intensities of Atlantic hurricanes may increase by 1.8–4.2 % and their lifetime maximum intensities may increase by 2.7–5.3 % when comparing the last two decades of the 20th and 21st centuries. We then combine our estimates of hurricane intensity changes with projections of sea-level rise to understand their relative impacts on future storm surge using simulations with the National Weather Service’s SLOSH (Sea, Lake, and Overland Surges from Hurricanes) model for five historical hurricanes that made landfall in the Gulf of Mexico and Florida. Considering uncertainty in hurricane intensity changes and sea-level rise, our results indicate a median increase in storm surge ranging between 25 and 47 %, with changes in hurricane intensity increasing future storm surge by about 10 % relative to the increase that may result from sea level rise alone, with highly non-linear response of population at risk.

  2. Proceedings of the third ICFA mini-workshop on high intensity, high brightness hadron accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Roser, T.

    1997-11-01

    The third mini-workshop on high intensity, high brightness hadron accelerators was held at Brookhaven National Laboratory on May 7-9, 1997 and had about 30 participants. The workshop focussed on rf and longitudinal dynamics issues relevant to intense and/or bright hadron synchrotrons. A plenary session was followed by four sessions on particular topics. This document contains copies of the viewgraphs used as well as summaries written by the session chairs.

  3. Proceedings of the third ICFA mini-workshop on high intensity, high brightness hadron accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Roser, T.

    1997-11-01

    The third mini-workshop on high intensity, high brightness hadron accelerators was held at Brookhaven National Laboratory on May 7-9, 1997 and had about 30 participants. The workshop focussed on rf and longitudinal dynamics issues relevant to intense and/or bright hadron synchrotrons. A plenary session was followed by four sessions on particular topics. This document contains copies of the viewgraphs used as well as summaries written by the session chairs.

  4. Blood coagulation using High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Nguyen, Phuc V.; Oh, Junghwan; Kang, Hyun Wook

    2014-03-01

    High Intensity Focused Ultrasound (HIFU) technology provides a feasible method of achieving thermal coagulation during surgical procedures. One of the potential clinical benefits of HIFU can induce immediate hemostasis without suturing. The objective of this study was to investigate the efficiency of a HIFU system for blood coagulation on severe vascular injury. ngHIFU treatment was implemented immediately after bleeding in artery. The ultrasound probe was made of piezoelectric material, generating a central frequency of 2.0 MHz as well as an ellipsoidal focal spot of 2 mm in lateral dimension and 10 mm in axial dimension. Acoustic coagulation was employed on a perfused chicken artery model in vitro. A surgical incision (1 to 2 mm long) was made with a scapel on the arterial wall, and heparinized autologous blood was made to leak out from the incision with a syringe pump. A total of 5 femoral artery incisions was treated with the HIFU beam. The intensity of 4500 W/cm2 at the focus was applied for all treatments. Complete hemostasis was achieved in all treatments, along with the treatment times of 25 to 50 seconds. The estimated intraoperative blood loss was from 2 to 5 mL. The proposed HIFU system may provide an effective method for immediate blood coagulation for arteries and veins in clinical applications.

  5. Pedalling rate affects endurance performance during high-intensity cycling

    DEFF Research Database (Denmark)

    Nielsen, Jens Steen; Hansen, Ernst Albin; Sjøgaard, Gisela

    2004-01-01

    , such as muscle fibre type composition and power reserve, relate to endurance time. Twenty males underwent testing to determine their maximal oxygen uptake (VO(2max)), power output corresponding to 90% of VO(2max) at 80 rpm (W90), FCPR at W90, percentage of slow twitch muscle fibres (% MHC I), maximal leg power...... time was negatively related to VO(2max), W90 and % MHC I, while positively related to power reserve. In conclusion, at group level, endurance time was longer at FCPR and at a pedalling rate 25% lower compared to a pedalling rate 25% higher than FCPR. Further, inter-individual physiological variables......The purpose of this study into high-intensity cycling was to: (1) test the hypothesis that endurance time is longest at a freely chosen pedalling rate (FCPR), compared to pedalling rates 25% lower (FCPR-25) and higher (FCPR+25) than FCPR, and (2) investigate how physiological variables...

  6. Vortex dynamics and shear layer instability in high intensity cyclotrons

    CERN Document Server

    Cerfon, Antoine J

    2016-01-01

    We show that the space charge dynamics of high intensity beams in the plane perpendicular to the magnetic field in cyclotrons is described by the two-dimensional Euler equations for an incompressible fluid. This analogy with fluid dynamics gives a unified and intuitive framework to explain the beam spiraling and beam break up behavior observed in experiments and in simulations. In particular, we demonstrate that beam break up is the result of a classical instability occurring in fluids subject to a sheared flow. We give scaling laws for the instability and predict the nonlinear evolution of beams subject to it. Our work suggests that cyclotrons may be uniquely suited for the experimental study of shear layers and vortex distributions that are not achievable in Penning-Malmberg traps.

  7. Simplified shielding calculation system for high-intensity proton accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Masumura, Tomomi; Nakashima, Hiroshi; Nakane, Yoshihiro; Sasamoto, Nobuo [Center for Neutron Science, Tokai Research Establishment, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-06-01

    A simplified shielding calculation system is developed for applying conceptual shielding design of facilities in the joint project for high-intensity proton accelerators. The system is composed of neutron transmission calculation part for bulk shielding using simplified formulas: Moyer model and Tesch's formula, and neutron skyshine calculation part using an empirical formula: Stapleton's formula. The system is made with the Microsoft Excel software for user's convenience. This report provides a manual for the system as well as calculation conditions used in the calculation such as Moyer model's parameters. In this report preliminary results based on data at December 8, 1999, are also shown as an example. (author)

  8. Repeated high-intensity exercise in a professional rugby league.

    Science.gov (United States)

    Austin, Damien J; Gabbett, Tim J; Jenkins, David J

    2011-07-01

    The primary aim of this study was to identify and describe the frequency and duration of repeated high-intensity exercise (RHIE) bouts in Australian professional rugby league (National Rugby League) and whether these occurred at critical times during a game. Time motion analysis was used during 5 competition matches; 1 player from 3 positional groups (hit-up forward, adjustable, and outside back) was analyzed in each match. The ranges of RHIE bouts for the 3 positional groups were hit-up forwards 9-17, adjustables 2-8, and outside backs 3-7. Hit-up forwards were involved in a significantly greater number of RHIE bouts (p rugby league players are likely to encounter.

  9. Fast damping in mismatched high intensity beam transportation

    Directory of Open Access Journals (Sweden)

    V. Variale

    2001-08-01

    Full Text Available A very fast damping of beam envelope oscillation amplitudes was recently observed in simulations of high intensity beam transport, through periodic FODO cells, in mismatched conditions [V. Variale, Nuovo Cimento Soc. Ital. Fis. 112A, 1571–1582 (1999 and T. Clauser et al., in Proceedings of the Particle Accelerator Conference, New York, 1999 (IEEE, Piscataway, NJ, 1999, p. 1779]. A Landau damping mechanism was proposed at the origin of observed effect. In this paper, to further investigate the source of this fast damping, extensive simulations have been carried out. The results presented here support the interpretation of the mechanism at the origin of the fast damping as a Landau damping effect.

  10. Feeding cosmic star formation: exploring high-redshift molecular gas with CO intensity mapping

    Science.gov (United States)

    Breysse, Patrick C.; Rahman, Mubdi

    2017-06-01

    The study of molecular gas is crucial for understanding star formation, feedback and the broader ecosystem of a galaxy as a whole. However, we have limited understanding of its physics and distribution in all but the nearest galaxies. We present a new technique for studying the composition and distribution of molecular gas in high-redshift galaxies inaccessible to existing methods. Our proposed approach is an extension of carbon monoxide intensity mapping methods, which have garnered significant experimental interest in recent years. These intensity mapping surveys target the 115 GHz 12CO (1-0) line, but also contain emission from the substantially fainter 110 GHz 13CO (1-0) transition. The method leverages the information contained in the 13CO line by cross-correlating pairs of frequency channels in an intensity mapping survey. Since 13CO is emitted from the same medium as the 12CO, but saturates at a much higher column density, this cross-correlation provides valuable information about both the gas density distribution and isotopologue ratio, inaccessible from the 12CO alone. Using a simple model of these molecular emission lines, we show that a future intensity mapping survey can constrain the abundance ratio of these two species and the fraction of emission from optically thick regions to order ˜30 per cent. These measurements cannot be made by traditional CO observations, and consequently the proposed method will provide unique insight into the physics of star formation, feedback and galactic ecology at high redshifts.

  11. New Zealand Blackcurrant Extract Improves High-Intensity Intermittent Running.

    Science.gov (United States)

    Perkins, Ian Craig; Vine, Sarah Anne; Blacker, Sam David; Willems, Mark Elisabeth Theodorus

    2015-10-01

    We examined the effect of New Zealand blackcurrant (NZBC) extract on high-intensity intermittent running and postrunning lactate responses. Thirteen active males (age: 25 ± 4 yrs, height: 1.82 ± 0.07 m, body mass: 81 ± 14 kg, VO2max: 56 ± 4 ml·kg-1·min-1, vVO2max: 17.6 ± 0.8 km·h-1) performed a treadmill running protocol to exhaustion, which consisted of stages with 6 × 19 s of sprints with 15 s of low-intensity running between sprints. Interstage rest time was 1 min and stages were repeated with increasing sprint speeds. Subjects consumed capsuled NZBC extract (300 mg·day-1 CurraNZ; containing 105 mg anthocyanin) or placebo for 7 days (double-blind, randomized, crossover design, wash-out at least 14 days). Blood lactate was collected for 30 min postexhaustion. NZBC increased total running distance by 10.6% (NZBC: 4282 ± 833 m, placebo: 3871 ± 622 m, p = .02), with the distance during sprints increased by 10.8% (p = .02). Heart rate, oxygen uptake, lactate and rating of perceived exertion were not different between conditions for the first 4 stages completed by all subjects. At exhaustion, blood lactate tended to be higher for NZBC (NZBC: 6.01 ± 1.07 mmol·L-1, placebo: 5.22 ± 1.52 mmol·L-1, p = .07). There was a trend for larger changes in lactate following 15 min (NZBC: -2.89 ± 0.51 mmol·L-1, placebo: -2.46 ± 0.39 mmol·L-1, p = .07) of passive recovery. New Zealand blackcurrant extract (CurraNZ) may enhance performance in sports characterized by high-intensity intermittent exercise as greater distances were covered with repeated sprints, there was higher lactate at exhaustion, and larger changes in lactate during early recovery after repeated sprints to exhaustion.

  12. New initiatives on lepton flavor violation and neutrino oscillation with high intense muon and neutrino sources

    CERN Document Server

    Kuno, Yoshitaka; Pakvasa, Sandip

    2002-01-01

    The area of physics involving muons and neutrinos has become exciting in particle physics. Using their high intensity sources, physicists undertake, in various ways, extensive searches for new physics beyond the Standard Model, such as tests of supersymmetric grand unification (SUSY-GUT) and precision measurements of the muon and neutrino properties, which will in future extend to ambitious studies such as determination of the three-generation neutrino mixing matrix elements and CP violation in the lepton sector. The physics of this field is advancing, with potential improvements of the source

  13. Nanobiotechnology promotes noninvasive high-intensity focused ultrasound cancer surgery.

    Science.gov (United States)

    Chen, Yu; Chen, Hangrong; Shi, Jianlin

    2015-01-07

    The successful cancer eradication in a noninvasive manner is the ultimate objective in the fight against cancer. As a "bloodless scalpel," high-intensity focused ultrasound (HIFU) is regarded as one of the most promising and representative noninvasive therapeutic modalities for cancer surgery. However, large-scale clinical applications of HIFU are still in their infancy because of critical efficiency and safety issues which remain to be solved. Fortunately, recently developed nanobiotechnology provides an alternative efficient approach to improve such important issues in HIFU, especially for cancer therapy. This Research News presents the very recent exciting progresses on the elaborate design and fabrication of organic, inorganic, and organic/inorganic hybrid nanoparticles for enhancing the HIFU ablation efficiency against tumor tissues. It is highly expected that this Research News can arouse more extensive research enthusiasm on the development of functional nanomaterials for highly efficient HIFU-based synergistic therapy, which will give a promising noninvasive therapeutic modality for the successful cancer therapy with minimal damage to surrounding normal tissues, due to the noninvasive and site-specific therapeutic features of HIFU.

  14. Bunching high intensity proton beams with a CH-DTL

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Malte; Claessens, Christine; Heilmann, Manuel; Hinrichs, Ole; Koser, Daniel; Meusel, Oliver; Noll, Daniel; Podlech, Holger; Ratzinger, Ulrich; Seibel, Anja [Institut fuer Angewandte Physik, Goethe-Universitaet Frankfurt am Main (Germany)

    2014-07-01

    The Frankfurt Neutron Source at the Stern-Gerlach-Zentrum (FRANZ) will provide ultra short neutron pulses at high intensities and repetition rates. The facility is under construction with an expected first beam by the end of 2014. A 5-Gap CH rebuncher is installed behind a coupled RFQ/IH-DTL combination at the end of the LINAC section between two magnetic quadrupole triplets. It will be used for varying the final energy between 1.8 and 2.2 MeV, as well as for focusing the proton beam bunch longitudinally, to compensate RF defocusing effects and huge space charge forces at currents up to 200 mA at the final stage of extension. Therefore high current beam dynamic simulations are in progress. They include benchmarking of different beam dynamic codes like LORASR, TraceWin and Bender (a new PIC tracking code developed at IAP), as well as validating the results by measurements. Detailed error tolerance studies, thermal simulations and examination of multipole field impact, due to the cavity geometry, are also done. Furthermore, this CH rebuncher serves as prototype for CH cavity operation at MYRRHA (Belgium), an Accelerator Driven System (ADS) for transmutation of high level nuclear waste. After copper-plating the cavity, RF conditioning will start in spring 2014.

  15. Spine radiosurgery for the local treatment of spine metastases: Intensity-modulated radiotherapy, image guidance, clinical aspects and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Fabio Ynoe de; Neves-Junior, Wellington Furtado Pimenta; Hanna, Samir Abdallah; Carvalho, Heloisa de Andrade [Hospital Sirio-Libanes, Sao Paulo, SP (Brazil). Departamento de Radioterapia; Taunk, Neil Kanth; Yamada, Yoshiya [Memorial Sloan Kettering Cancer Center, Department of Radiation Oncology, New York, NY (United States); Laufer, Ilya, E-mail: fymoraes@gmail.com [Memorial Sloan Kettering Cancer Center, Department of Neurosurgery, New York, NY (United States)

    2016-02-15

    Many cancer patients will develop spinal metastases. Local control is important for preventing neurologic compromise and to relieve pain. Stereotactic body radiotherapy or spinal radiosurgery is a new radiation therapy technique for spinal metastasis that can deliver a high dose of radiation to a tumor while minimizing the radiation delivered to healthy, neighboring tissues. This treatment is based on intensity-modulated radiotherapy, image guidance and rigid immobilization. Spinal radiosurgery is an increasingly utilized treatment method that improves local control and pain relief after delivering ablative doses of radiation. Here, we present a review highlighting the use of spinal radiosurgery for the treatment of metastatic tumors of the spine. The data used in the review were collected from both published studies and ongoing trials. We found that spinal radiosurgery is safe and provides excellent tumor control (up to 94% local control) and pain relief (up to 96%), independent of histology. Extensive data regarding clinical outcomes are available; however, this information has primarily been generated from retrospective and non randomized prospective series. Currently, two randomized trials are enrolling patients to study clinical applications of fractionation schedules spinal Radiosurgery. Additionally, a phase I clinical trial is being conducted to assess the safety of concurrent stereotactic body radiotherapy and ipilimumab for spinal metastases. Clinical trials to refine clinical indications and dose fractionation are ongoing. The concomitant use of targeted agents may produce better outcomes in the future. (author)

  16. Observation of fine particle aggregating behavior induced by high intensity conditioning using high speed CCD

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The aggregating behavior between bubbles and particles induced by high intensity conditioning (HIC) was studied using high speed CCD technique. Bubble size measurement was conducted, and the attachment behavior between bubbles and particles in HIC cell and flotation cell were observed. The results show that in HIC cell, high intensity conditioning creates an advantage environment for the formation of small size bubble due to hydrodynamic cavitations, and these fine bubbles have high probability of bubble-particle collision,which will enhance fine particle flotation. The bubble-particle attachment experiments indicate that in high intensity conditioning cell, a lot of fine bubbles are produced in situ on the surface of fine particles, and most of fine particles are aggregated under the bridging action of fine bubbles. The observation of bubble-particle interaction in flotation cell illustrates that aggregates created by HIC can be loaded more easily by big air bubble in flotation cell than those created by normal conditioning.

  17. High-order harmonic generation at high laser intensities beyond the tunnel regime

    CERN Document Server

    Pérez-Hernández, J A; Lewenstein, M; Zaïr, A; Roso, L

    2014-01-01

    We present studies of high-order harmonic generation (HHG) at laser intensities well above saturation. We use driving laser pulses which present a particular electron dynamics in the turn-on stage. Our results predict an increasing on the harmonic yield, after an initial dropping, when the laser intensity is increased. This fact contradicts the general belief of a progressive degradation of the harmonic emission at ultrahigh intensities. We have identified a particular set of trajectories which emerges in the turn-on stage of these singular laser pulses, responsible of the unexpected growth on the harmonic efficiency at this high intensity regime. Our study combines two complementary approaches: classical analysis and full quantum mechanical calculations resulting from the numerical integration of the 3-dimensional time-dependent Schr\\"odinger equation complemented with the time-frequency analysis.

  18. Echinococcus granulosus: protoscolicidal effect of high intensity focused ultrasound.

    Science.gov (United States)

    Zou, Xiaoyi; Wang, Junan; Zhao, Hailong; Zhang, Jing; Wu, Weihua; Ye, Bin

    2009-04-01

    High intensity focused ultrasound (HIFU) is a new non-invasive technique which can cause cell death and tissue necrosis by focusing high-energy ultrasonic waves on a single location. The aim of our work is to investigate the damaging effect of HIFU on Echinococcus granulosus protoscolices, as well as its inhibitory effect on growth of hydatid cysts derived from protoscolices. The damaging effect of HIFU on protoscolices was investigated by following parasite mortality after irradiation, while the inhibitory effect was investigated by infection experiments in vivo. The results demonstrated that HIFU was able to damage protoscolices and the protoscolicidal effect was dose-dependent and showed late-onset. The growth of protoscolices that survived the exposure to HIFU was obviously suppressed in vitro, and the mean weight of hydatid cysts resulting from such protoscolices in the experimental group was less than that in controls. Evidences including the protoscolicidal effect, fragmentized protoscolices and low post exposure temperatures, suggest that cavitation may contribute to the protoscolicidal effect of HIFU. In addition, the structure of the germinal membrane in cysts developing from the irradiated protoscolices was not as normal or intact as that from non-irradiated ones, and morphological changes related to degeneration were observed, suggesting that HIFU could prevent protoscolices from developing normal germinal membrane and consequently stop the proliferation of secondary hydatid cysts. HIFU demonstrated damaging effect on protoscolices, inhibited the growth of protoscolices in vitro and in vivo, and could be a possible therapeutic option for cystic echinococcosis.

  19. Interaction of High Intensity Electromagnetic Waves with Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    G. Shvets

    2008-10-03

    The focus of our work during the duration of this grant was on the following areas: (a) the fundamental plasma physics of intense laser-plasma interactions, including the nonlinear excitation of plasma waves for accelerator applications, as well as the recently discovered by us phenomenon of the relativistic bi-stability of relativistic plasma waves driven by a laser beatwave; (b) interaction of high power microwave beams with magnetized plasma, including some of the recently discovered by us phenomena such as the Undulator Induced Transparency (UIT) as well as the new approaches to dynamic manipulation of microwave pulses; (c) investigations of the multi-color laser pulse interactions in the plasma, including the recently discovered by us phenomenon of Electromagnetic Cascading (EC) and the effect of the EC of three-dimensional dynamics of laser pulses (enhanced/suppressed selffocusing etc.); (d) interaction of high-current electron beams with the ambient plasma in the context of Fast Ignitor (FI) physics, with the emphasis on the nonlinear dynamics of the Weibel instability and beam filamentation.

  20. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika;

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT...... high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance...... in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group....

  1. Lipid emulsions in parenteral nutrition of intensive care patients: current thinking and future directions.

    NARCIS (Netherlands)

    Calder, P.C.; Jensen, G.L.; Koletzko, B.V.; Singer, P.; Wanten, G.J.A.

    2010-01-01

    BACKGROUND: Energy deficit is a common and serious problem in intensive care units and is associated with increased rates of complications, length of stay, and mortality. Parenteral nutrition (PN), either alone or in combination with enteral nutrition, can improve nutrient delivery to critically ill

  2. Creatine kinase response to high-intensity aerobic exercise in adult-onset muscular dystrophy

    DEFF Research Database (Denmark)

    Andersen, Søren P; Sveen, Marie-Louise; Hansen, Regitze S

    2013-01-01

    We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies.......We investigated the effect of high-intensity exercise on plasma creatine kinase (CK) in patients with muscular dystrophies....

  3. Compliance with High-Intensity Radiated Fields Regulations - Emitter's Perspective

    Science.gov (United States)

    Statman, Joseph; Jamnejad, Vahraz; Nguyen, Lee

    2012-01-01

    NASA's Deep Space Network (DSN) uses high-power transmitters on its large antennas to communicate with spacecraft of NASA and its partner agencies. The prime reflectors of the DSN antennas are parabolic, at 34m and 70m in diameter. The DSN transmitters radiate Continuous Wave (CW) signals at 20 kW - 500 kW at X-band and S-band frequencies. The combination of antenna reflector size and high frequency results in a very narrow beam with extensive oscillating near-field pattern. Another unique feature of the DSN antennas is that they (and the radiated beam) move mostly at very slow sidereal rate, essentially identical in magnitude and at the opposite direction of Earth rotation.The DSN is in the process of revamping its documentation to provide analysis of the High Intensity Radiation Fields (HIRF) environment resulting from radio frequency radiation from DSN antennas for comparison to FAA regulations regarding certification of HIRF protection as outlined in the FAA regulations on HIRF protection for aircraft electrical and electronic systems (Title 14, Code of Federal Regulations (14 CFR) [section sign][section sign] 23.1308, 25.1317, 27.1317, and 29.1317).This paper presents work done at JPL, in consultation with the FAA. The work includes analysis of the radiated field structure created by the unique DSN emitters (combination of transmitters and antennas) and comparing it to the fields defined in the environments in the FAA regulations. The paper identifies areas that required special attention, including the implications of the very narrow beam of the DSN emitters and the sidereal rate motion. The paper derives the maximum emitter power allowed without mitigation and the mitigation zones, where required.Finally, the paper presents summary of the results of the analyses of the DSN emitters and the resulting DSN process documentation.

  4. High-intensity interval training vs. moderate-intensity continuous training in the prevention/management of cardiovascular disease

    OpenAIRE

    S Hussain; Macaluso, A; Pearson, S.

    2016-01-01

    Moderate-intensity continuous training (MICT) has long been considered the most effective exercise treatment modality for the prevention and management of cardiovascular disease, but more recently high-intensity interval training (HIIT) has emerged into the clinical environment has been viewed as a potential alternative to MICT in accruing such benefits. HIIT was initially found to induce significant improvements in numerous physiological and health-related indices, to a similar if not superi...

  5. High intensity ultrasound modified ovalbumin: Structure, interface and gelation properties.

    Science.gov (United States)

    Xiong, Wenfei; Wang, Yuntao; Zhang, Chunlan; Wan, Jiawei; Shah, Bakht Ramin; Pei, Yaqiong; Zhou, Bin; Li, Jin; Li, Bin

    2016-07-01

    Influence of high intensity ultrasound (HIUS) on the structure and properties of ovalbumin (OVA) were investigated. It was found that the subunits and secondary structure of OVA did not change significantly with HIUS treatment from the electrophoretic patterns and circular dichroism (CD) spectrum. The amount of free sulfhydryl groups increased and intrinsic fluorescence spectra analysis indicated changes in the tertiary structure and partial unfold of OVA after sonication increased. Compared with the untreated OVA, HIUS treatment increased the emulsifying activity and foaming ability, and decreased interface tension (oil-water and air-water interface), which due to the increased surface hydrophobicity and decreased the surface net charge in OVA, while the emulsifying and foaming stability had no remarkable differences. The increased particle size may be attributed to formation of protein aggregates. Moreover, the gelation temperatures of HIUS-treated samples were higher than the untreated OVA according to the temperature sweep model rheology, and this effect was consistent with the increased in surface hydrophobicity for ultrasound treated OVA. These changes in functional properties of OVA would promote its application in food industry. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Treatment of glaucoma with high intensity focused ultrasound.

    Science.gov (United States)

    Aptel, Florent; Lafon, Cyril

    2015-05-01

    Glaucoma is a common disease mainly due to an increase in pressure inside the eye, leading to a progressive destruction of the optic nerve, potentially to blindness. Intraocular pressure (IOP) is the result of a balance between production of liquid that fills the eye--aqueous humour--and its resorption. All treatments for glaucoma aim to reduce IOP and can therefore have two mechanisms of action: reducing aqueous humour production by the partial destruction or medical inhibition of the ciliary body--the anatomical structure responsible for production of aqueous humour--or facilitating the evacuation of aqueous humour from the eye. Several physical methods can be used to destroy the ciliary body, e.g. laser, cryotherapy, microwave. All these methods have two major drawbacks: they are non-selective for the organ to be treated and they have an unpredictable dose–effect relationship. High intensity focused ultrasound (HIFU) can be used to coagulate the ciliary body and avoid these drawbacks. A commercially available device was marketed in the 1980s, but later abandoned, essentially for technical reasons. A smaller circular device using miniaturised transducers was recently developed and proposed for clinical practice. Experimental studies have shown selective coagulation necrosis of the treated ciliary body. The first three clinical trials in humans have shown that this device was well tolerated and allowed a significant, predictable and sustained reduction of IOP. The aim of this contribution is to present a summary of the work concerning the use of HIFU to treat glaucoma.

  7. Robotic Assisted Laparoscopic Prostatectomy after High Intensity Focused Ultrasound Failure

    Directory of Open Access Journals (Sweden)

    Leon Telis

    2017-01-01

    Full Text Available Background. Prostate cancer is the most common cancer diagnosed in men. As new focal therapies become more popular in treatment of prostate cancer, failure cases requiring salvage therapy with either surgical or other techniques are being reported. Objective. To report the options in treatment of prostate cancer after recurrence or failure of the primary treatment modality. Methods. We report a salvage robotic assisted laparoscopic radical prostatectomy (RALP for prostate cancer recurrence following high intensity focused ultrasound treatment (HIFU in the United States. Results. A 67-year-old man who underwent HIFU treatment for prostate adenocarcinoma 2 years prior was presented with a rising prostate specific antigen of 6.1 ng/mL to our clinic. A biopsy proven recurrent disease in the area of previous treatment documented the failure of treatment. The patient elected to undergo a salvage RALP. The operation time was 159 minutes. The patient was discharged from the hospital on postoperative day 1 with no complications. The catheter was removed on post-op day 10. The patient reserved sexual function and urinary continence. The PSA levels on 6 months’ follow-up are undetectable. Conclusions. Salvage RALP is an effective and safe treatment choice for recurrent prostate adenocarcinoma following failed HIFU treatment if operated by an experienced surgeon.

  8. Inelastic scattering in condensed matter with high intensity Moessbauer radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yelon, W.B.; Schupp, G.

    1990-10-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS{sub 2}, which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support.

  9. Gamma scattering in condensed matter with high intensity Moessbauer radiation

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    We give a progress report for the work which has been carried out in the last three years with DOE support. A facility for high-intensity Moessbauer scattering is now fully operational at the University of Missouri Research Reactor (MURR) as well as a facility at Purdue, using special isotopes produced at MURR. High precision, fundamental Moessbauer effect studies have been carried out using scattering to filter the unwanted radiation. These have led to a new Fourier transform method for describing Moessbauer effect (ME) lineshape and a direct method of fitting ME data to the convolution integral. These methods allow complete correction for source resonance self absorption (SRSA) and the accurate representation of interference effects that add an asymmetric component to the ME lines. We have begun applying these techniques to attenuated ME sources whose central peak has been attenuated by stationary resonant absorbers, to more precisely determine interference parameters and line-shape behavior in the resonance asymptotic region. This analysis is important to both the fundamental ME studies and to scattering studies for which a deconvolution is essential for extracting the correct recoilless fractions and interference parameters. A number of scattering studies have been successfully carried out including a study of the thermal diffuse scattering in Si, which led to an analysis of the resolution function for gamma-ray scattering. Also studied was the anharmonic motion in Na and the satellite reflection Debye-Waller factor in TaS{sub 2}, which indicate phason rather than phonon behavior. We have begun quasielastic diffusion studies in viscous liquids and current results are summarized. These advances, coupled to our improvements in MIcrofoil Conversion Electron spectroscopy lay the foundation for the proposed research outlined in this request for a three-year renewal of DOE support.

  10. High intensity ultrasound transducer used in gene transfection

    Science.gov (United States)

    Morrison, Kyle P.; Keilman, George W.; Noble, Misty L.; Brayman, Andrew A.; Miao, Carol H.

    2012-11-01

    This paper describes a novel therapeutic high intensity non-focused ultrasound (HIU) transducer designed with uniform pressure distribution to aid in accelerated gene transfer in large animal liver tissues in vivo. The underlying HIU transducer was used to initiate homogeneous cavitation throughout the tissue while delivering up to 2.7 MPa at 1.1 MHz across its radiating surface. The HIU transducer was built into a 6 cm diameter x 1.3 cm tall housing ergonomically designed to avoid collateral damage to the surrounding anatomy during dynamic motion. The ultrasound (US) radiation was applied in a 'paintbrush-like' manner to the surface of the liver. The layers and geometry of the transducer were carefully selected to maximize the active diameter (5.74 cm), maximize the electrical to acoustic conversion efficiency (85%) to achieve 2.7 MPa of peak negative pressure, maximize the frequency operating band at the fundamental resonance to within a power transfer delta of 1 dB, and reduce the pressure delta to within 2 dB across the radiating surface. For maximum peak voltage into the transducer, a high performance piezoceramic was chosen and a DC bias circuit was built integral to the system. An apodized two element annular pattern was made from a single piezoceramic element, resulting in significant pressure uniformity enhancement. In addition to using apodization for pressure uniformity, a proprietary multi-layered structure was used to improve efficiency while sustaining an operating band from 900 kHz to 1.3 MHz. The resultant operating band allowed for dithering techniques using frequency modulation. The underlying HIU transducer for use in large animals enhances gene expression up to 6300-fold.

  11. HIGH-INTENSITY FOCUSED ULTRASOUND CASTRATION FOR BREAST CANCER PATIENTS

    Institute of Scientific and Technical Information of China (English)

    王书文; 和新盈; 石景森; 赵东利; 李明众; 王诚; 薛文华

    2003-01-01

    Objective: To evaluate the safety and efficacy of external high-intensity focused ultrasound(HIFU) castration for breast cancerous patients after mastectomy if they are at a high risk of recurrence. Methods: We recruited 52 consecutive patients with primary operable breast cancer who were treated with mastectomy with excision of regional lymph nodes. Patients were positive for ER and PR immuno- cytochemical staining, node-positive, un-menopause, over 40 years old and were divided into two groups randomly. For castration, 26 patients received one or two times of HIFU treatment within five days, and the other patients received radiotherapy with DT 18Gy/9 f/11days. During and after the treatment, local changes and systemic response of the patients were observed. Results: After 1 month treatment, levels of serum E1 and E2 were significantly decreased compared to before treatment in HIFU groups (P<0.01 and P<0.001). The same changes were occurred in radiotherapy(RT) groups (P<0.05 and P<0.01). The levels of serum E1 or E2 in RT groups were higher than in HIFU groups (P<0.05). The symptom distribution of 'climacteric syndrome' of HIFU groups were significantly different from RT groups (P<0.01). The follow-up time was 4 months. The incidence of amenorrhea was 100% in all patients. No serious complications were seen. The temperature, pulse, blood pressure, and respiratory rate of the patients were almost normal. Conclusion: We have shown that the use of HIFU in the castrating of patients with breast cancer is feasible, safe and effective. This technology may provide a rapid noninvasive alterative to conventional bilateral oophorectomy or RT castration.

  12. High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

    Energy Technology Data Exchange (ETDEWEB)

    Gauthier, M., E-mail: maxence.gauthier@stanford.edu; Kim, J. B.; Curry, C. B.; Gamboa, E. J.; Göde, S.; Propp, A.; Glenzer, S. H. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Aurand, B.; Willi, O. [Heinrich-Heine-University Düsseldorf, Düsseldorf (Germany); Goyon, C.; Hazi, A.; Pak, A.; Ruby, J.; Williams, G. J. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Kerr, S. [University of Alberta, Edmonton, Alberta T6G 1R1 (Canada); Ramakrishna, B. [Indian Institute of Technology, Hyderabad (India); Rödel, C. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Friedrich-Schiller-University Jena, Jena (Germany)

    2016-11-15

    We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

  13. High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

    Science.gov (United States)

    Gauthier, M.; Kim, J. B.; Curry, C. B.; Aurand, B.; Gamboa, E. J.; Göde, S.; Goyon, C.; Hazi, A.; Kerr, S.; Pak, A.; Propp, A.; Ramakrishna, B.; Ruby, J.; Willi, O.; Williams, G. J.; Rödel, C.; Glenzer, S. H.

    2016-11-01

    We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

  14. Comparison between Epidural Block vs. High Intensity Laser Therapy for Controlling Chronic Low Back Pain

    Directory of Open Access Journals (Sweden)

    Badiozaman Radpay

    2016-01-01

    Full Text Available Background: Chronic low back pain is among a wide spread musculoskeletal conditions that is related to disability with high economy cost. There are several treatment modalities for controlling chronic low back pain (CLBP, among them high intensity laser therapy (HILT and epidural blocks (EB use more commonly. This study aimed to evaluate the benefits and hazards of each of these two methods.Materials and Methods: We designed a randomized controlled double blind study during 24 months.101 patients divided in 2 groups (52 in EB and 49 in HILT group. Pain intensity was assessed by using faces pain scales (FPS and LINKERT questionaries' before procedure and during one, four, 12, and 24 weeks after beginning the procedures.Results: There were no differences between two groups in FPS lumber tenderness, straight leg rising test (SLRT, paresthesia, deep tendon reflex (DTR, and imaging changes. Motor problems seem was less in HILT group comparing EB.Conclusion: This study showed both EB and HILT approaches can control the pain intensity and motor activities in CLBP patients. Future studies will clarify the precise importance of each these methods.

  15. High performance computing: Clusters, constellations, MPPs, and future directions

    Energy Technology Data Exchange (ETDEWEB)

    Dongarra, Jack; Sterling, Thomas; Simon, Horst; Strohmaier, Erich

    2003-06-10

    Last year's paper by Bell and Gray [1] examined past trends in high performance computing and asserted likely future directions based on market forces. While many of the insights drawn from this perspective have merit and suggest elements governing likely future directions for HPC, there are a number of points put forth that we feel require further discussion and, in certain cases, suggest alternative, more likely views. One area of concern relates to the nature and use of key terms to describe and distinguish among classes of high end computing systems, in particular the authors use of ''cluster'' to relate to essentially all parallel computers derived through the integration of replicated components. The taxonomy implicit in their previous paper, while arguable and supported by some elements of our community, fails to provide the essential semantic discrimination critical to the effectiveness of descriptive terms as tools in managing the conceptual space of consideration. In this paper, we present a perspective that retains the descriptive richness while providing a unifying framework. A second area of discourse that calls for additional commentary is the likely future path of system evolution that will lead to effective and affordable Petaflops-scale computing including the future role of computer centers as facilities for supporting high performance computing environments. This paper addresses the key issues of taxonomy, future directions towards Petaflops computing, and the important role of computer centers in the 21st century.

  16. The effect of high and low exercise intensity periods on a simple memory recognition test

    Directory of Open Access Journals (Sweden)

    Ben Rattray

    2016-09-01

    Conclusion: Changes in cognitive performance with variations in exercise intensity are likely to have implications for sport and occupational settings. The timing of cognitive tests to exercise intensity changes as well as use of short cognitive assessments will be important for future work.

  17. Visions of the Future - the Changing Role of Actors in Data-Intensive Science

    Science.gov (United States)

    Schäfer, L.; Klump, J. F.

    2013-12-01

    Around the world scientific disciplines are increasingly facing the challenge of a burgeoning volume of research data. This data avalanche consists of a stream of information generated from sensors and scientific instruments, digital recordings, social-science surveys or drawn from the World Wide Web. All areas of the scientific economy are affected by this rapid growth in data, from the logging of digs in Archaeology, telescope data with observations of distant galaxies in Astrophysics or data from polls and surveys in the Social Sciences. The challenge for science is not only to process the data through analysis, reduction and visualization, but also to set up infrastructures for provisioning and storing the data. The rise of new technologies and developments also poses new challenges for the actors in the area of research data infrastructures. Libraries, as one of the actors, enable access to digital media and support the publication of research data and its long-term archiving. Digital media and research data, however, introduce new aspects into the libraries' range of activities. How are we to imagine the library of the future? The library as an interface to the computer centers? Will library and computer center fuse into a new service unit? What role will scientific publishers play in future? Currently the traditional form of publication still carry greater weight - articles for conferences and journals. But will this still be the case in future? New forms of publication are already making their presence felt. The tasks of the computer centers may also change. Yesterday their remit was provisioning of rapid hardware, whereas now everything revolves around the topic of data and services. Finally, how about the researchers themselves? Not such a long time ago, Geoscience was not necessarily seen as linked to Computer Science. Nowadays, modern Geoscience relies heavily on IT and its techniques. Thus, in how far will the profile of the modern geoscientist change

  18. (Very)-high-energy gamma-ray astrophysics: The future

    Science.gov (United States)

    De Angelis, Alessandro

    2016-04-01

    Several projects planned or proposed can significantly expand our knowledge of the high-energy Universe in gamma rays. Construction of the Cherenkov telescope array CTA is started, and other detectors are planned which will use the reconstruction of extensive air showers. This report explores the near future, and possible evolutions in a longer term.

  19. (Very)-High-Energy Gamma-Ray Astrophysics: the Future

    CERN Document Server

    De Angelis, Alesandro

    2016-01-01

    Several projects planned or proposed can significantly expand our knowledge of the high-energy Universe in gamma rays. Construction of the Cherenkov telescope array CTA is started, and other detectors are planned which will use the reconstruction of extensive air showers. This report explores the near future, and possible evolutions in a longer term.

  20. (Very-high-energy gamma-ray astrophysics: The future

    Directory of Open Access Journals (Sweden)

    Angelis Alessandro De

    2016-01-01

    Full Text Available Several projects planned or proposed can significantly expand our knowledge of the high-energy Universe in gamma rays. Construction of the Cherenkov telescope array CTA is started, and other detectors are planned which will use the reconstruction of extensive air showers. This report explores the near future, and possible evolutions in a longer term.

  1. Advanced approaches to high intensity laser-driven ion acceleration

    Energy Technology Data Exchange (ETDEWEB)

    Henig, Andreas

    2010-04-26

    Since the pioneering work that was carried out 10 years ago, the generation of highly energetic ion beams from laser-plasma interactions has been investigated in much detail in the regime of target normal sheath acceleration (TNSA). Creation of ion beams with small longitudinal and transverse emittance and energies extending up to tens of MeV fueled visions of compact, laser-driven ion sources for applications such as ion beam therapy of tumors or fast ignition inertial con finement fusion. However, new pathways are of crucial importance to push the current limits of laser-generated ion beams further towards parameters necessary for those applications. The presented PhD work was intended to develop and explore advanced approaches to high intensity laser-driven ion acceleration that reach beyond TNSA. In this spirit, ion acceleration from two novel target systems was investigated, namely mass-limited microspheres and nm-thin, free-standing diamond-like carbon (DLC) foils. Using such ultrathin foils, a new regime of ion acceleration was found where the laser transfers energy to all electrons located within the focal volume. While for TNSA the accelerating electric field is stationary and ion acceleration is spatially separated from laser absorption into electrons, now a localized longitudinal field enhancement is present that co-propagates with the ions as the accompanying laser pulse pushes the electrons forward. Unprecedented maximum ion energies were obtained, reaching beyond 0.5 GeV for carbon C{sup 6+} and thus exceeding previous TNSA results by about one order of magnitude. When changing the laser polarization to circular, electron heating and expansion were shown to be efficiently suppressed, resulting for the first time in a phase-stable acceleration that is dominated by the laser radiation pressure which led to the observation of a peaked C{sup 6+} spectrum. Compared to quasi-monoenergetic ion beam generation within the TNSA regime, a more than 40 times

  2. Evaluation of the productivity decrease risk due to a future increase in tropical cyclone intensity in Japan.

    Science.gov (United States)

    Esteban, Miguel; Longarte-Galnares, Gorka

    2010-12-01

    A number of scientists have recently conducted research that shows that tropical cyclone intensity is likely to increase in the future. This would result in an increase in the damage along with a decrease in economic productivity due to precautionary cessation of the economic activity of the affected areas during the passage of the cyclone. The economic effect of this stop in economic activity is a phenomenon that has not received much attention in the past, and the cumulative effect that it can have on the Japanese economy over the next 75 years has never been evaluated. The starting point for the evaluation of the economic risks is the change in the patterns of tropical cyclone intensity suggested by Knutson and Tuleya. The results obtained show how a significant decrease in the overall productivity of the country could be expected, which could lower GDP by between 6% and 13% by 2085.

  3. High-quality lossy compression: current and future trends

    Science.gov (United States)

    McLaughlin, Steven W.

    1995-01-01

    This paper is concerned with current and future trends in the lossy compression of real sources such as imagery, video, speech and music. We put all lossy compression schemes into common framework where each can be characterized in terms of three well-defined advantages: cell shape, region shape and memory advantages. We concentrate on image compression and discuss how new entropy constrained trellis-based compressors achieve cell- shape, region-shape and memory gain resulting in high fidelity and high compression.

  4. High-Intensity Training and Salivary Immunoglobulin A Responses in Professional Top-Level Soccer Players: Effect of Training Intensity.

    Science.gov (United States)

    Owen, Adam L; Wong, Del P; Dunlop, Gordon; Groussard, Carole; Kebsi, Wiem; Dellal, Alexandre; Morgans, Ryland; Zouhal, Hassane

    2016-09-01

    Owen, AL, Wong, DP, Dunlop, G, Groussard, C, Kebsi, W, Dellal, A, Morgans, R, and Zouhal, H. High-intensity training and salivary immunoglobulin A responses in professional top-level soccer players: Effect of training intensity. J Strength Cond Res 30(9): 2460-2469, 2016-This study aimed (a) to test the hypothesis that salivary immunoglobulin A (s-IgA) would vary with training intensity sessions (low-intensity [LI] vs. high-intensity sessions [HI]) during a traditional training program divided into 4 training periods and (b) to identify key variables (e.g., GPS data, rating of perceived exertion [RPE], and training duration), which could affect s-IgA. Saliva samples of 10 elite professional soccer players were collected (a) before the investigation started to establish the baseline level and (b) before and after each 4 training sessions (LI vs. HI). Training intensity was monitored as internal (through heart rate responses and RPE) and external (through GPS) loads. High-intensity sessions were associated with higher external load (GPS) and with higher RPE. Baseline and pretraining s-IgA did not differ between the 4 training sessions both for HI and LI. Post-training s-IgA were not different (in absolute value and in percentage of change) between HI and LI sessions at the first 3 periods. However, at the fourth period, s-IgA concentration for HI session was significantly lower (p ≤ 0.05) than the LI session. The percentage change between s-IgA post-training and s-IgA baseline concentrations differ significantly (p ≤ 0.05) between HI and LI training sessions. Significant correlations between s-IgA and training intensity were also noted. High-intensity soccer training sessions might cause a significant decrease in s-IgA values during the postexercise window as compared with LI sessions. This study encourages coaches to monitor s-IgA in routine, particularly during HI training periods, to take precautions to avoid upper respiratory tract infection in highly trained

  5. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT perfor...

  6. Simulations On Pair Creation In Collision Of γ-Beams Produced With High Intensity Lasers

    Science.gov (United States)

    Jansen, Oliver; Ribeyre, Xavier; D'Humieres, Emmanuel; Lobet, Mathieu; Jequier, Sophie; Tikhonchuk, Vladimir

    2016-10-01

    Direct production of electron-positron pairs in two photon collisions, the Breit-Wheeler process, is one of the most basic processes in the universe. However, this process has never been directly observed in the laboratory due to the lack of high intensity γ sources. For a feasibility study and for the optimisation of experimental set-ups we developed a high-performance tree-code. Different possible set-ups with MeV photon sources were discussed and compared using collision detection for huge number of particles in a quantum-electrodynamic regime. The authors acknowledge the financial support from the French National Research Agency (ANR) in the framework of ''The Investments for the Future'' programme IdEx Bordeaux - LAPHIA (ANR-10IDEX-03-02)-Project TULIMA.

  7. Final Report for "Modeling Electron Cloud Diagnostics for High-Intensity Proton Accelerators"

    Energy Technology Data Exchange (ETDEWEB)

    Seth A Veitzer

    2009-09-25

    Electron clouds in accelerators such as the ILC degrade beam quality and limit operating efficiency. The need to mitigate electron clouds has a direct impact on the design and operation of these accelerators, translating into increased cost and reduced performance. Diagnostic techniques for measuring electron clouds in accelerating cavities are needed to provide an assessment of electron cloud evolution and mitigation. Accurate numerical modeling of these diagnostics is needed to validate the experimental techniques. In this Phase I, we developed detailed numerical models of microwave propagation through electron clouds in accelerating cavities with geometries relevant to existing and future high-intensity proton accelerators such as Project X and the ILC. Our numerical techniques and simulation results from the Phase I showed that there was a high probability of success in measuring both the evolution of electron clouds and the effects of non-uniform electron density distributions in Phase II.

  8. High-Intensity Femtosecond Laser Interaction with Rare Gas Clusters

    Institute of Scientific and Technical Information of China (English)

    林亚风; 钟钦; 曾淳; 陈哲

    2001-01-01

    With a 45 fs multiterawatt 790 nm laser system and jets of argon and krypton atomic clusters, a study of the interaction of fs intense laser pulses with large size rare gas dusters was conducted. The maximum laser intensity of about 7 × 1016 W/cm2 and dusters composed of thousands of atoms which were determined through Rayleigh scattering measurements were involved inthe experiments. On the one hand, the results indicate that the interaction is strongly cluster size dependent. The stronger the interaction, the larger the clusters are. On the other hand, a saturation followed by a drop of the energy of ions ejected from the interaction will occur when the laser intensity exceeds a definite value for clusters of a certain size.

  9. Intensive Multi-Perspective Seminar on Nepal-China Relations:Past,Present and Future Held in Nepal

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    <正>The Intensive Multi-Perspective Seminar on Nepal-China relations: Past, Present and Future, sponsored by Nepal World Culture Net, was held from August 1 to 3 in the capital Kathmandu, to mark the 56th anniversary of diplomatic ties. CPAFFC Vice President Jing Dunquan headed a delegation consisting of government officials, experts and scholars from the Tibet Autonomous Region, Sichuan Pro- vince, Xi’an City, Chengdu City and China Radio International. They had discussions with personages from Nepalese political, economic and cultural circles, expressed their views and offered suggestions on the present bilateral relations as well as development prospects.

  10. Experimental results of beryllium exposed to intense high energy proton beam pulses

    Energy Technology Data Exchange (ETDEWEB)

    Ammigan, K. [Fermilab; Hartsell, B. [Fermilab; Hurh, P. [Fermilab; Zwaska, R. [Fermilab; Butcher, M. [CERN; Guinchard, M. [CERN; Calviani, M. [CERN; Losito, R. [CERN; Roberts, S. [Culham Lab; Kuksenko, V. [Oxford U.; Atherton, A. [Rutherford; Caretta, O. [Rutherford; Davenne, T. [Rutherford; Densham, C. [Rutherford; Fitton, M. [Rutherford; Loveridge, J. [Rutherford; O' Dell, J. [Rutherford

    2017-02-10

    Beryllium is extensively used in various accelerator beam lines and target facilities as a material for beam windows, and to a lesser extent, as secondary particle production targets. With increasing beam intensities of future accelerator facilities, it is critical to understand the response of beryllium under extreme conditions to reliably operate these components as well as avoid compromising particle production efficiency by limiting beam parameters. As a result, an exploratory experiment at CERN’s HiRadMat facility was carried out to take advantage of the test facility’s tunable high intensity proton beam to probe and investigate the damage mechanisms of several beryllium grades. The test matrix consisted of multiple arrays of thin discs of varying thicknesses as well as cylinders, each exposed to increasing beam intensities. This paper outlines the experimental measurements, as well as findings from Post-Irradiation-Examination (PIE) work where different imaging techniques were used to analyze and compare surface evolution and microstructural response of the test matrix specimens.

  11. The High Luminosity Challenge: potential and limitations of High Intensity High Brightness in the LHC and its injectors

    CERN Document Server

    De Maria, R; Banfi, D; Barranco, J; Bartosik, H; Benedetto, E; Bruce, R; Brüning, O; Calaga, R; Cerutti, F; Damerau, H; Esposito, L; Fartoukh, S; Fitterer, M; Garoby, R; Gilardoni, S; Giovannozzi, M; Goddard, B; Gorini, B; Hanke, K; Iadarola, G; Lamont, M; Meddahi, M; Métral, E; Mikulec, B; Mounet, N; Papaphilippou, Y; Pieloni, T; Redaelli, S; Rossi, L; Rumolo, G; Shaposhnikova, E; Sterbini, G; Todesco, E; Tomás, R; Zimmermann, F; Valishev, A

    2014-01-01

    High-intensity and high-brightness beams are key ingredients to maximize the LHC integrated luminosity and to exploit its full potential. This contribution describes the optimization of beam and machine parameters to maximize the integrated luminosity as seen by the LHC experiments, by taking into account the expected intensity and brightness reach of LHC itself and its injector chain as well as the capabilities of the detectors for next run and foreseen upgrade scenarios.

  12. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul; Dudnikov, Vadim

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  13. H- Ion Sources for High Intensity Proton Drivers

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Rolland Paul [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Dudnikov, Vadim [Muons, Inc., Batavia, IL (United States)

    2015-02-20

    Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm2 per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency, reliability and availability for pulsed operation as used in the ORNL Spallation Neutron Source . At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the aluminum nitride (AlN) discharge chamber for 32 days at high discharge power in an RF SPS with an external antenna. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. While this project demonstrated the advantages of the pulsed version of the SA RF SPS as an upgrade to the ORNL Spallation Neutron Source, it led to a possibility for upgrades to CW machines like the many cyclotrons used for commercial applications. Four appendices contain important details of the work carried out under this grant.

  14. Proton Acceleration Drived by High-intensity Ultraviolet Laser

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    The generation of energetic protons from a solid thin-foil by the interactions of ultra-short and intense laser pulses is investigated in numerous experiments in the last decade. The energetic proton beams are promising candidates for proton fast ignitor (PFI)

  15. Overview of novel photovoltaic conversion techniques at high intensity levels

    Science.gov (United States)

    Stirn, R. J.

    1978-01-01

    The paper describes several photovoltaic devices currently under development that can operate under light intensities considerably higher than can silicon solar cells. The technologies discussed include GaAs heteroface solar cells, multi-color systems, thermophotovoltaics, and laser energy conversion. Array costs for the GaAs and multi-color elements are estimated.

  16. Experimental Research at the Intensity Frontier in High Energy Physics

    Energy Technology Data Exchange (ETDEWEB)

    Marshak, Marvin L. [Univ. of Minnesota, Minneapolis, MN (United States)

    2014-06-30

    This Final Report describes DOE-supported Intensity Frontier research by the University of Minnesota during the interval April 1, 2011 to March 31, 2014. Primary activities included the MINOS, NOvA and LBNE Experiments and Heavy Quark studies at BES III.

  17. 基于生物技术的集约农业—未来农业的希望%Biotechnological-intensive Farming System-The Best Hope for Future

    Institute of Scientific and Technical Information of China (English)

    Abdul Razzaq; 马峙英

    2004-01-01

    Future challenges of agriculture inevitably demand knowledge and technology based revitalization of farming. A strategic and rational resource management approach has to be adopted for achieving the productivity enhancement goals without compromising on natural resources. Intensive farming system characterized by intensive use of chemical inputs, though made it possible to significantly increase the productivity during 20th century assuring proper food for the growing population, created several health and environmental concerns, compromised on crop quality and has become cost intensive. Its potential is exhausted. However, these problems are not the inevitable consequences of intensive farming system. These problems can be readdressed and their intensity can be alleviated by shifting-over to "Biotechnological-intensive Farming System". Biotechnology and genetic transformation techniques in combination with conventional breeding methods can producebetter quality and high yielding novel crops with enhanced nutritional level, resistant to biotic and abiotic stresses leading to less use of chemicals thereby lowering the production cost and ameliorating the problems affiliated with intensive farming system.Biotechnological-intensive Farming System has a greater potential to meet the future challenges of food production in 21st century for burgeoning population. It is compatible with the objective of integrated resource management for sustainability of agricultural resource foundation and is human and environment friendly. Combining biotechnological innovations and genetic modification of crops with farming under a suitable policy framework is our best hope for the future.

  18. Max Tech and Beyond: High-Intensity Discharge Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable

  19. REPORT OF RESEARCH ACCOMPLISHMENTS AND FUTURE GOALS HIGH ENERGY PHYSICS

    Energy Technology Data Exchange (ETDEWEB)

    Wise, Mark B. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Kapustin, Anton N. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Schwarz, John Henry [California Inst. of Technology (CalTech), Pasadena, CA (United States); Carroll, Sean [California Inst. of Technology (CalTech), Pasadena, CA (United States); Ooguri, Hirosi [California Inst. of Technology (CalTech), Pasadena, CA (United States); Gukov, Sergei [California Inst. of Technology (CalTech), Pasadena, CA (United States); Preskill, John [California Inst. of Technology (CalTech), Pasadena, CA (United States); Hitlin, David G. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Porter, Frank C. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Patterson, Ryan B. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Newman, Harvey B. [California Inst. of Technology (CalTech), Pasadena, CA (United States); Spiropulu, Maria [California Inst. of Technology (CalTech), Pasadena, CA (United States); Golwala, Sunil [California Inst. of Technology (CalTech), Pasadena, CA (United States); Zhu, Ren-Yuan [California Inst. of Technology (CalTech), Pasadena, CA (United States)

    2014-08-26

    Caltech High Energy Physics (HEP) has a broad program in both experimental and theoretical physics. We are known for our creativity and leadership. The future is uncertain and we strive to be involved in all the major areas of experimental and theoretical HEP physics so no matter where the important discoveries occur we are well positioned to play an important role. An outstanding group of postdoctoral scholars, graduate students, staff scientists, and technical and administrative personnel support our efforts in experimental and theoretical physics. The PI’s on this grant are involved in the following program of experimental and theoretical activities: I) EXPERIMENTAL PHYSICS Our CMS group, led by Harvey Newman and Maria Spiropulu, has played a key role in the discovery and interpretation of the Higgs boson and in searches for new physics. They have important hardware responsibilities in both ECAL and HCAL and are also involved in the upgrades needed for the High Luminosity LHC. Newman's group also develops and operates Grid-based computing, networking, and collaborative systems for CMS and the US HEP community. The charged lepton (Mu2e) and quark BaBar flavor physics group is led by David Hitlin and Frank Porter. On Mu2e they have been instrumental in the design of the calorimeter. Construction responsibilities include one third of the crystals and associated readout as well as the calibration system. They also will have responsibility for a major part of the online system software. Although data taking ceased in 2008 the Caltech BaBar group is active on several new forefront analyses. The neutrino group is led by Ryan Patterson. They are central to NOvA's core oscillation physics program, to calibration, and to detector readiness being responsible for the production and installation of 12,000 APD arrays. They have key roles in neutrino appearance and disappearance analysis in MINOS and MINOS+. Sunil Golwala leads the dark matter direct detection

  20. REPORT OF RESEARCH ACCOMPLISHMENTS AND FUTURE GOALS HIGH ENERGY PHYSICS

    Energy Technology Data Exchange (ETDEWEB)

    Wise, Mark B. [California Institute of Technology; Kapustin, Anton N. [California Institute of Technology; Schwarz, John Henry [California Institute of Technology; Carroll, Sean [California Institute of Technology; Ooguri, Hirosi [California Institute of Technology; Gukov, Sergei [California Institute of Technology; Preskill, John [California Institute of Technology; Hitlin, David G. [California Institute of Technology; Porter, Frank C. [California Institute of Technology; Patterson, Ryan B. [California Institute of Technology; Newman, Harvey B. [California Institute of Technology; Spiropulu, Maria [California Institute of Technology; Golwala, Sunil [California Institute of Technology; Zhu, Ren-Yuan

    2014-08-26

    Caltech High Energy Physics (HEP) has a broad program in both experimental and theoretical physics. We are known for our creativity and leadership. The future is uncertain and we strive to be involved in all the major areas of experimental and theoretical HEP physics so no matter where the important discoveries occur we are well positioned to play an important role. An outstanding group of postdoctoral scholars, graduate students, staff scientists, and technical and administrative personnel support our efforts in experimental and theoretical physics. The PI’s on this grant are involved in the following program of experimental and theoretical activities: I) EXPERIMENTAL PHYSICS Our CMS group, led by Harvey Newman and Maria Spiropulu, has played a key role in the discovery and interpretation of the Higgs boson and in searches for new physics. They have important hardware responsibilities in both ECAL and HCAL and are also involved in the upgrades needed for the High Luminosity LHC. Newman's group also develops and operates Grid-based computing, networking, and collaborative systems for CMS and the US HEP community. The charged lepton (Mu2e) and quark BaBar flavor physics group is led by David Hitlin and Frank Porter. On Mu2e they have been instrumental in the design of the calorimeter. Construction responsibilities include one third of the crystals and associated readout as well as the calibration system. They also will have responsibility for a major part of the online system software. Although data taking ceased in 2008 the Caltech BaBar group is active on several new forefront analyses. The neutrino group is led by Ryan Patterson. They are central to NOvA's core oscillation physics program, to calibration, and to detector readiness being responsible for the production and installation of 12,000 APD arrays. They have key roles in neutrino appearance and disappearance analysis in MINOS and MINOS+. Sunil Golwala leads the dark matter direct detection

  1. Cardiorespiratory fitness modulates the acute flow-mediated dilation response following high-intensity but not moderate-intensity exercise in elderly men.

    Science.gov (United States)

    Bailey, Tom G; Perissiou, Maria; Windsor, Mark; Russell, Fraser; Golledge, Jonathan; Green, Daniel J; Askew, Christopher D

    2017-05-01

    cycling exercise in higher fit men, with a sustained reduction in FMD in lower fit men. The prolonged reduction in FMD after high-intensity cycling exercise may be associated with future vascular adaptation but may also reflect a period of increased cardiovascular risk in lower fit elderly men. Copyright © 2017 the American Physiological Society.

  2. Max Tech and Beyond: High-Intensity Discharge Lamps

    Energy Technology Data Exchange (ETDEWEB)

    Scholand, Michael

    2012-04-01

    High-intensity discharge (HID) lamps are most often found in industrial and commercial applications, and are the light source of choice in street and area lighting, and sports stadium illumination. HID lamps are produced in three types - mercury vapor (MV), high pressure sodium (HPS) and metal halide (MH). Of these, MV and MH are considered white-light sources (although the MV exhibits poor color rendering) and HPS produces a yellow-orange color light. A fourth lamp, low-pressure sodium (LPS), is not a HID lamp by definition, but it is used in similar applications and thus is often grouped with HID lamps. With the notable exception of MV which is comparatively inefficient and in decline in the US from both a sales and installed stock point of view; HPS, LPS and MH all have efficacies over 100 lumens per watt. The figure below presents the efficacy trends over time for commercially available HID lamps and LPS, starting with MV and LPS in 1930's followed by the development of HPS and MH in the 1960's. In HID lamps, light is generated by creating an electric arc between two electrodes in an arc tube. The particles in the arc are partially ionized, making them electrically conductive, and a light-emitting 'plasma' is created. This arc occurs within the arc tube, which for most HID lamps is enclosed within an evacuated outer bulb that thermally isolates and protects the hot arc tube from the surroundings. Unlike a fluorescent lamp that produces visible light through down-converting UV light with phosphors, the arc itself is the light source in an HID lamp, emitting visible radiation that is characteristic of the elements present in the plasma. Thus, the mixture of elements included in the arc tube is one critical factor determining the quality of the light emitted from the lamp, including its correlated color temperature (CCT) and color rendering index (CRI). Similar to fluorescent lamps, HID lamps require a ballast to start and maintain stable

  3. Design Work for the High-Energy Storage Ring for Antiprotons of the Future GSI Project

    CERN Document Server

    Lehrach, Andreas; Boine-Frankenheim, Oliver; Bongardt, Klaus; Dietrich, J; Dolinskii, Alexei V; Eichhorn, Ralf; Gålnander, B; Hinterberger, Frank; Lorentz, Bernd; Maier, Rudolf; Martin, Siegfried; Prasuhn, Dieter; Reistad, Dag; Senichev, Yurij; Senicheva, Eugenia; Steck, Markus; Stockhorst, Hans; Tölle, Raimund; Zaplatin, Evgeny

    2005-01-01

    The High-Energy Storage Ring (HESR) of the future international Facility for Antiproton and Ion Research (FAIR) at GSI in Darmstadt is planned as an antiproton cooler and storage ring in the momentum range from 1.5 to 15 GeV/c. The design work for the HESR is organized by a consortium with scientists from FZ Jülich, GSI Darmstadt and TSL Uppsala. An important feature of the new facility is the combination of phase space cooled beams with internal targets, resulting in demanding beam parameter in two operation modes: high luminosity mode with beam intensities up to few times 1011

  4. Understanding laser-solid interactions at ultra-high intensities

    Science.gov (United States)

    Murphy, C. D.; Gray, R. J.; Carroll, D. C.; MacLellan, D. A.; Powell, H.; Scott, G. G.; Ridgers, C. P.; Brady, C. S.; Neely, D.; Green, J. S.; Booth, N.; McKenna, P.

    2012-10-01

    The interaction of matter with lasers is a subject which has progressed rapidly over the last two decades as higher intensity lasers have opened the door to nonlinear and then relativistic interactions such that applications in ion acceleration and x-ray backlighting sources have become a clear possibility. Until recently, lasers capable of reaching the highest intensities (˜10^21 Wcm-2) have been glass-based systems with a low shot rate making detailed studies prohibitively time consuming. The development of petawatt-class Ti:Sapphire lasers such as Astra Gemini at STFC - Rutherford Appleton Laboratory, has made the systematic studies required to understand such interaction physics feasible. One such experiment on the Astra Gemini laser will be presented. The photon and particle diagnostics used will be explained and their results presented.

  5. High-Intensity Focused Ultrasound in Small Renal Masses

    Directory of Open Access Journals (Sweden)

    Jose Rubio Briones

    2008-01-01

    Therapeutic results are controversial and from an clinical view, HIFU must be considered a technique under investigation at present time. Further research is needed to settle its real indications in the management of small renal masses; maybe technical improvements will certainly facilitate its use in the management of small renal masses in the near future.

  6. Ionization Chambers for Monitoring in High-Intensity Neutrino Beams

    CERN Document Server

    McDonald, J; Velissaris, C; Erwin, A R; Ping, H; Viren, B M; Diwan, M V

    2002-01-01

    Radiation-hard ionization chambers were tested using an intense electron beam from the accelerator test facility (ATF) at the Brookhaven National Laboratory (BNL). The detectors were designed to be used as the basic element for monitoring muons in the Main Injector Neutrino beamline (NuMI) at the Fermi National Accelerator Laboratory (FNAL). Measurements of linearity of response, voltage dependence, and the onset of ionization saturation as a function of gap voltage were performed.

  7. Development of a cryogenic hydrogen microjet for high-intensity, high-repetition rate experiments

    Science.gov (United States)

    Kim, J. B.; Göde, S.; Glenzer, S. H.

    2016-11-01

    The advent of high-intensity, high-repetition-rate lasers has led to the need for replenishing targets of interest for high energy density sciences. We describe the design and characterization of a cryogenic microjet source, which can deliver a continuous stream of liquid hydrogen with a diameter of a few microns. The jet has been imaged at 1 μm resolution by shadowgraphy with a short pulse laser. The pointing stability has been measured at well below a mrad, for a stable free-standing filament of solid-density hydrogen.

  8. High-intensity focused ultrasound for thyroid nodule ablation: the evidence to date

    Directory of Open Access Journals (Sweden)

    Kovatcheva RD

    2017-01-01

    Full Text Available Roussanka D Kovatcheva,1 Katja Zaletel,2 1Department of Thyroid and Metabolic Bone Disorders, Clinical Center of Endocrinology, Medical University, Sofia, Bulgaria; 2Department of Nuclear Medicine, University Medical Centre Ljubljana, Ljubljana, Slovenia Abstract: Thyroid nodules are common in occurrence and most of them are benign in nature. Some of these nodules are to be treated as they continue to grow or cause undesirable symptoms. Recently, several minimally invasive thermal ablation techniques have been introduced to overcome the complications of traditional methods such as surgery. High-intensity focused ultrasound (HIFU is the latest advance in treatment modalities, which is a noninvasive procedure that permits localized target destruction without affecting the surrounding tissues. HIFU is currently used in the treatment of various solid malignant and benign tumors. The purpose of this review is to provide an introduction to the literature, principles, and advances of HIFU therapy of benign thyroid nodules, as well as to provide a discussion on its efficacy, complications, and future. Keywords: thyroid nodule, high-intensity focused ultrasound, ultrasound guidance, ablation techniques

  9. A mask for high-intensity heavy-ion beams in the MAYA active target

    Energy Technology Data Exchange (ETDEWEB)

    Rodríguez-Tajes, C., E-mail: rodriguez@ganil.fr [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Bvd Henri Becquerel, 14076 Caen (France); Universidade de Santiago de Compostela, E-15706 Santiago de Compostela (Spain); Pancin, J.; Damoy, S.; Roger, T.; Babo, M. [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Bvd Henri Becquerel, 14076 Caen (France); Caamaño, M. [Universidade de Santiago de Compostela, E-15706 Santiago de Compostela (Spain); Farget, F.; Grinyer, G.F.; Jacquot, B.; Pérez-Loureiro, D. [Grand Accélérateur National d' Ions Lourds (GANIL), CEA/DSM-CNRS/IN2P3, Bvd Henri Becquerel, 14076 Caen (France); Ramos, D. [Universidade de Santiago de Compostela, E-15706 Santiago de Compostela (Spain); Suzuki, D. [Institut de Physique Nucléaire, Université Paris-Sud 11, CNRS/IN2P3, F-91406 Orsay (France)

    2014-12-21

    The use of high-intensity and/or heavy-ion beams in active targets and time-projection chambers is often limited by the strong ionization produced by the beam. Besides the difficulties associated with the saturation of the detector and electronics, beam-related signals may hide the physical events of interest or reduce the detector performance. In addition, space-charge effects may deteriorate the homogeneity of the electric drift field and distort the subsequent reconstruction of particle trajectories. In anticipation of future projects involving such conditions, a dedicated beam mask has been developed and tested in the MAYA active target. Experimental results with a {sup 136}Xe beam are presented.

  10. A mask for high-intensity heavy-ion beams in the MAYA active target

    Science.gov (United States)

    Rodríguez-Tajes, C.; Pancin, J.; Damoy, S.; Roger, T.; Babo, M.; Caamaño, M.; Farget, F.; Grinyer, G. F.; Jacquot, B.; Pérez-Loureiro, D.; Ramos, D.; Suzuki, D.

    2014-12-01

    The use of high-intensity and/or heavy-ion beams in active targets and time-projection chambers is often limited by the strong ionization produced by the beam. Besides the difficulties associated with the saturation of the detector and electronics, beam-related signals may hide the physical events of interest or reduce the detector performance. In addition, space-charge effects may deteriorate the homogeneity of the electric drift field and distort the subsequent reconstruction of particle trajectories. In anticipation of future projects involving such conditions, a dedicated beam mask has been developed and tested in the MAYA active target. Experimental results with a 136Xe beam are presented.

  11. Channeling of multikilojoule high-intensity laser beams in an inhomogeneous plasma

    Energy Technology Data Exchange (ETDEWEB)

    Ivancic, S. [Univ. of Rochester, Rochester, NY (United States); Haberberger, D. [Univ. of Rochester, Rochester, NY (United States); Habara, H. [Osaka Univ., Suita (Japan); Iwawaki, T. [Osaka Univ., Suita (Japan); Anderson, K. S. [Univ. of Rochester, Rochester, NY (United States); Craxton, R. S. [Univ. of Rochester, Rochester, NY (United States); Froula, D. H. [Univ. of Rochester, Rochester, NY (United States); Meyerhofer, D. D. [Univ. of Rochester, Rochester, NY (United States); Stoeckl, C. [Univ. of Rochester, Rochester, NY (United States); Tanaka, K. A. [Osaka Univ., Suita (Japan); Theobald, W. [Univ. of Rochester, Rochester, NY (United States)

    2015-05-01

    Channeling experiments were performed that demonstrate the transport of high-intensity (>10¹⁸ W/cm²), multikilojoule laser light through a millimeter-sized, inhomogeneous (~300-μm density scale length) laser produced plasma up to overcritical density, which is an important step forward for the fast-ignition concept. The background plasma density and the density depression inside the channel were characterized with a novel optical probe system. The channel progression velocity was measured, which agrees well with theoretical predictions based on large scale particle-in-cell simulations, confirming scaling laws for the required channeling laser energy and laser pulse duration, which are important parameters for future integrated fast-ignition channeling experiments.

  12. Design Considerations of Fast Kicker Systems for High Intensity Proton Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W; Sandberg, J; Parson, W M; Walstrom, P; Murray, M M; Cook, E; Hartouni, E

    2001-06-12

    In this paper, we discuss the specific issues related to the design of the Fast Kicker Systems for high intensity proton accelerators. To address these issues in the preliminary design stage can be critical since the fast kicker systems affect the machine lattice structure and overall design parameters. Main topics include system architecture, design strategy, beam current coupling, grounding, end user cost vs. system cost, reliability, redundancy and flexibility. Operating experience with the Alternating Gradient Synchrotron injection and extraction kicker systems at Brookhaven National Laboratory and their future upgrade is presented. Additionally, new conceptual designs of the extraction kicker for the Spallation Neutron Source at Oak Ridge and the Advanced Hydrotest Facility at Los Alamos are discussed.

  13. Detailed studies of Minor Actinide transmutation-incineration in high-intensity neutron fluxes

    Energy Technology Data Exchange (ETDEWEB)

    Bringer, O. [CEA/Saclay/DSM/DAPNIA, Gif-sur-Yvette (France); Al Mahamid, I. [Lawrence Berkeley National Laboratory, E.H. and S. Div., CA (United States); Blandin, C. [CEA/Cadarache/DEN/DER/SPEX, Saint-Paul-lez-Durances (France); Chabod, S. [CEA/Saclay/DSM/DAPNIA, Gif-sur-Yvette (France); Chartier, F. [CEA/Cadarache/DEN/DPC/SECR, Gif-sur-Yvette (France); Dupont, E.; Fioni, G. [CEA/Saclay/DSM/DAPNIA, Gif-sur-Yvette (France); Isnard, H. [CEA/Cadarache/DEN/DPC/SECR, Gif-sur-Yvette (France); Letourneau, A.; Marie, F. [CEA/Saclay/DSM/DAPNIA, Gif-sur-Yvette (France); Mutti, P. [Institut Laue-Langevin, Grenoble (France); Oriol, L. [CEA/Cadarache/DEN/DER/SPEX, Saint-Paul-lez-Durances (France); Panebianco, S.; Veyssiere, C. [CEA/Saclay/DSM/DAPNIA, Gif-sur-Yvette (France)

    2006-07-01

    The Mini-INCA project is dedicated to the measurement of incineration-transmutation chains and potentials of minor actinides in high-intensity thermal neutron fluxes. In this context, new types of detectors and methods of analysis have been developed. The {sup 241}Am and {sup 232}Th transmutation-incineration chains have been studied and several capture and fission cross sections measured very precisely, showing some discrepancies with existing data or evaluated data. An impact study was made on different based-like GEN-IV reactors. It underlines the necessity to proceed to precise measurements for a large number of minor-actinides that contribute to these future incineration scenarios. (authors)

  14. Application of the speed-duration relationship to normalize the intensity of high-intensity interval training.

    Directory of Open Access Journals (Sweden)

    Carrie Ferguson

    Full Text Available The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8 then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4, 6 min (WR6 and 8 min (WR8, interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min. A sub-group of subjects (n = 6 also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (P0.050. However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m, 3 (136.9±38.9 m, and 4 (136.7±39.3 m, compared with bout 1 (264.9±58.7 m; P>0.050. These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols.

  15. Application of the speed-duration relationship to normalize the intensity of high-intensity interval training.

    Science.gov (United States)

    Ferguson, Carrie; Wilson, John; Birch, Karen M; Kemi, Ole J

    2013-01-01

    The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM) relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT) has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8) then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4), 6 min (WR6) and 8 min (WR8), interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT) on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4×4 min). A sub-group of subjects (n = 6) also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT) to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4×4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399±81 s for WR4, 892±181 s for WR6 and 1517±346 s for WR8, with total exercise durations all significantly different from each other (PHIIT, there was no difference in tLIM of each of the 4 bouts (Bout 1: 229±27 s; Bout 2: 262±37 s; Bout 3: 235±49 s; Bout 4: 235±53 s; P>0.050). However, there was significantly less high-intensity work completed during bouts 2 (153.5±40. 9 m), 3 (136.9±38.9 m), and 4 (136.7±39.3 m), compared with bout 1 (264.9±58.7 m; P>0.050). These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols.

  16. Causative factors of high intensity areas identified by MRI in the pontine base

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Masaki; Takahashi, Akira [Nagoya Univ. (Japan). Faculty of Medicine; Arahata, Yutaka; Motegi, Yoshimasa

    1994-08-01

    High intensity areas in the pontine base were found more frequently in patients of group A who had multiple supratentorial high intensity areas smaller than 15 mm in size and of group B whose vertebral arteries were asymmetric on MR angiography, as compared to those who had none of the above findings of MRI and MR angiography. The high intensity areas of group A were often found bilaterally in the upper pons and those of group B were present unilaterally in the lower pons. Pontine high intensity areas were found frequently on the same side as the smaller vertebral artery in group B. Periventricular hyperintensity was more severe in group A than than in group B. These results suggest that high intensity lesions in the pontine base may conform with the following conditions: (1) multiple small high intensity areas in the supratentorium due to diffuse arteriosclerosis, and (2) asymmetry of the vertebral arteries inducing hemodynamic disorders. (author).

  17. Beam dynamics of mixed high intensity highly charged ion Beams in the Q/A selector

    Science.gov (United States)

    Zhang, X. H.; Yuan, Y. J.; Yin, X. J.; Qian, C.; Sun, L. T.; Du, H.; Li, Z. S.; Qiao, J.; Wang, K. D.; Zhao, H. W.; Xia, J. W.

    2017-06-01

    Electron cyclotron resonance (ECR) ion sources are widely used in heavy ion accelerators for their advantages in producing high quality intense beams of highly charged ions. However, it exists challenges in the design of the Q/A selection systems for mixed high intensity ion beams to reach sufficient Q/A resolution while controlling the beam emittance growth. Moreover, as the emittance of beam from ECR ion sources is coupled, the matching of phase space to post accelerator, for a wide range of ion beam species with different intensities, should be carefully studied. In this paper, the simulation and experimental results of the Q/A selection system at the LECR4 platform are shown. The formation of hollow cross section heavy ion beam at the end of the Q/A selector is revealed. A reasonable interpretation has been proposed, a modified design of the Q/A selection system has been committed for HIRFL-SSC linac injector. The features of the new design including beam simulations and experiment results are also presented.

  18. High efficiency USC power plant - present status and future potential

    Energy Technology Data Exchange (ETDEWEB)

    Blum, R. [Faelleskemikerne I/S Fynsvaerket (Denmark); Hald, J. [Elsam/Elkraft/TU Denmark (Denmark)

    1998-12-31

    Increasing demand for energy production with low impact on the environment and minimised fuel consumption can be met with high efficient coal fired power plants with advanced steam parameters. An important key to this improvement is the development of high temperature materials with optimised mechanical strength. Based on the results of more than ten years of development a coal fired power plant with an efficiency above 50 % can now be realised. Future developments focus on materials which enable an efficiency of 52-55 %. (orig.) 25 refs.

  19. The effect of progressive high-intensity inspiratory muscle training and fixed high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients.

    Science.gov (United States)

    Jung, Ju-Hyeon; Kim, Nan-Soo

    2015-10-01

    [Purpose] This study investigated the effects of progressive load and fixed load high-intensity inspiratory muscle training on the asymmetry of diaphragm thickness in stroke patients. [Subjects] Twenty-one stroke patients were assigned to one of three groups: progressive load high-intensity inspiratory muscle training (n = 8), fixed load high-intensity inspiratory muscle training (n = 6), and controls (n = 7). [Methods] The progressive load and fixed load high-intensity inspiratory muscle training participants undertook an exercise program for 20 minutes, three times weekly, for 6 weeks. After each session, diaphragm thickness was measured using ultrasonography. The diaphragm asymmetry ratio and diaphragm thickening ratio were standardized using a formula. [Results] After intervention, the diaphragm asymmetry ratio significantly differed among the three groups, and the diaphragm asymmetry ratio significantly increased in the control group. A significant increase was identified in the diaphragm thickening ratio within the progressive load and fixed load high-intensity inspiratory muscle training groups. [Conclusion] Progressive load and fixed load high-intensity inspiratory muscle training decreased the asymmetry of diaphragm thickness in stroke patients; this effect, in turn, increased the diaphragm thickening ratio in stroke patients. The two interventions examined here should be selectively applied to individuals in the clinical field.

  20. Intensity ratio measurements for density sensitive lines of highly charged Fe ions

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Safdar, E-mail: safdaruetian@gmail.com; Shimizu, Erina [Institute for Laser Science, The University of Electro-Communications (Japan); Sakaue, Hiroyuki A.; Kato, Daiji; Murakami, Izumi [National Institute for Fusion Science (Japan); Yamamoto, Norimasa [Chubu University (Japan); Hara, Hirohisa; Watanabe, Tetsuya [The Graduate University of Advanced Studies (SOKENDAI) (Japan); Nakamura, Nobuyuki, E-mail: n-nakamu@ils.uec.ac.jp [Institute for Laser Science, The University of Electro-Communications (Japan)

    2015-11-15

    Intensity ratio of density sensitive emission lines emitted from Fe ions in the extreme ultraviolet region is important for astrophysics applications. We report high-resolution intensity ratio measurements for Fe ions performed at Tokyo EBIT laboratory by employing a flat-field grazing incidence spectrometer. The experimental intensity ratios of Fe X and Fe XII are plotted as a function of electron density for different electron beam currents. The experimental results are compared with the predicted intensity ratios from the model calculations.

  1. Superconducting Magnet Technology for Future High Energy Proton Colliders

    Science.gov (United States)

    Gourlay, Stephen

    2017-01-01

    Interest in high field dipoles has been given a boost by new proposals to build a high-energy proton-proton collider to follow the LHC and programs around the world are taking on the task to answer the need. Studies aiming toward future high-energy proton-proton colliders at the 100 TeV scale are now being organized. The LHC and current cost models are based on technology close to four decades old and point to a broad optimum of operation using dipoles with fields between 5 and 12T when site constraints, either geographical or political, are not a factor. Site geography constraints that limit the ring circumference can drive the required dipole field up to 20T, which is more than a factor of two beyond state-of-the-art. After a brief review of current progress, the talk will describe the challenges facing future development and present a roadmap for moving high field accelerator magnet technology forward. This work was supported by the Director, Office of Science, High Energy Physics, US Department of Energy, under contract No. DE-AC02-05CH11231.

  2. Intensity dependence in high-level facial expression adaptation aftereffect.

    Science.gov (United States)

    Hong, Sang Wook; Yoon, K Lira

    2017-06-14

    Perception of a facial expression can be altered or biased by a prolonged viewing of other facial expressions, known as the facial expression adaptation aftereffect (FEAA). Recent studies using antiexpressions have demonstrated a monotonic relation between the magnitude of the FEAA and adaptor extremity, suggesting that facial expressions are opponent coded and represented continuously from one expression to its antiexpression. However, it is unclear whether the opponent-coding scheme can account for the FEAA between two facial expressions. In the current study, we demonstrated that the magnitude of the FEAA between two facial expressions increased monotonically as a function of the intensity of adapting facial expressions, consistent with the predictions based on the opponent-coding model. Further, the monotonic increase in the FEAA occurred even when the intensity of an adapting face was too weak for its expression to be recognized. These results together suggest that multiple facial expressions are encoded and represented by balanced activity of neural populations tuned to different facial expressions.

  3. Enhancing gas-phase reaction in a plasma using high intensity and high power ultrasonic acoustic waves

    DEFF Research Database (Denmark)

    2010-01-01

    is absorbed into said plasma (104), and where a sound pressure level of said generated ultrasonic high intensity and high power acoustic waves (102) is at least substantially 140 dB and where an acoustic power of said generated ultrasonic high intensity and high power acoustic waves (102); is at least......This invention relates to enhancing a gas-phase reaction in a plasma comprising: creating plasma (104) by at least one plasma source (106), and wherein that the method further comprises: generating ultrasonic high intensity and high power acoustic waves (102) having a predetermined amount...... of acoustic energy by at least one ultrasonic high intensity and high power gas-jet acoustic wave generator (101), where said ultrasonic high intensity and high power acoustic waves are directed to propagate towards said plasma (104) so that at least a part of said predetermined amount of acoustic energy...

  4. Personalized metabolomics for predicting glucose tolerance changes in sedentary women after high-intensity interval training

    National Research Council Canada - National Science Library

    Kuehnbaum, Naomi L; Gillen, Jenna B; Gibala, Martin J; Britz-McKibbin, Philip

    2014-01-01

    High-intensity interval training (HIIT) offers a practical approach for enhancing cardiorespiratory fitness, however its role in improving glucose regulation among sedentary yet normoglycemic women remains unclear...

  5. Nakagami imaging for detecting thermal lesions induced by high-intensity focused ultrasound in tissue.

    Science.gov (United States)

    Rangraz, Parisa; Behnam, Hamid; Tavakkoli, Jahan

    2014-01-01

    High-intensity focused ultrasound induces focalized tissue coagulation by increasing the tissue temperature in a tight focal region. Several methods have been proposed to monitor high-intensity focused ultrasound-induced thermal lesions. Currently, ultrasound imaging techniques that are clinically used for monitoring high-intensity focused ultrasound treatment are standard pulse-echo B-mode ultrasound imaging, ultrasound temperature estimation, and elastography-based methods. On the contrary, the efficacy of two-dimensional Nakagami parametric imaging based on the distribution of the ultrasound backscattered signals to quantify properties of soft tissue has recently been evaluated. In this study, ultrasound radio frequency echo signals from ex vivo tissue samples were acquired before and after high-intensity focused ultrasound exposures and then their Nakagami parameter and scaling parameter of Nakagami distribution were estimated. These parameters were used to detect high-intensity focused ultrasound-induced thermal lesions. Also, the effects of changing the acoustic power of the high-intensity focused ultrasound transducer on the Nakagami parameters were studied. The results obtained suggest that the Nakagami distribution's scaling and Nakagami parameters can effectively be used to detect high-intensity focused ultrasound-induced thermal lesions in tissue ex vivo. These parameters can also be used to understand the degree of change in tissue caused by high-intensity focused ultrasound exposures, which could be interpreted as a measure of degree of variability in scatterer concentration in various parts of the high-intensity focused ultrasound lesion.

  6. Nuclear Structure at the Legnaro National Laboratories:. from High Intensity Stable to Radioactive Nuclear Beams

    Science.gov (United States)

    de Angelis, G.

    2007-04-01

    To understand the properties of a nucleus, apart from establishing the interaction between its components, it is necessary to determine the arrangement of the nucleons, i.e. the structure of a nucleus. So far our knowledge about the structure of nuclei is mostly limited to nuclei close to the valley of stability, or nuclei with a deficiency of neutrons, which can be produced in fusion-evaporation reactions with stable beams and stable targets. Future perspectives in nuclear structure rely on radioactive ion beams (RIB) as well as on high intensity beams of stable ions (HISB). A world wide effort is presently going on in order to built the next generation radioactive ion beam facilities like the FAIR and the EURISOL projects. The LNL are contributing to such development through the design study of the EURISOL project as well as through the design and construction of the intermediate facility SPES. Concerning the instrumentation, particularly powerful is the combination of large acceptance spectrometers with highly segmented γ-detector arrays. An example is the CLARA γ-ray detector array coupled with the PRISMA spectrometer at the Legnaro National Laboratories (LNL). The physics aims achievable with such device complement studies performed with current radioactive beam (RIB) facilities. With this set-up we have recently investigated the stability of the N=50 shell closure. Here the comparison of the experimental data with shell model calculations seems to indicate a persistence of the N=50 shell gap down to Z=31. Also the study of proton rich nuclei can strongly benefit from the use of high intensity stable beams using fusion evaporation reactions at energies close to the Coulomb barrier. Future perspectives at LNL are based on an increase in intensity as well as on the availability of heavy ion species. Moreover a new ISOL facility (SPES) dedicated to the production and acceleration of radioactive neutron rich species is now under development at LNL. Among the new

  7. Towards phasing using high X-ray intensity

    Directory of Open Access Journals (Sweden)

    Lorenzo Galli

    2015-11-01

    Full Text Available X-ray free-electron lasers (XFELs show great promise for macromolecular structure determination from sub-micrometre-sized crystals, using the emerging method of serial femtosecond crystallography. The extreme brightness of the XFEL radiation can multiply ionize most, if not all, atoms in a protein, causing their scattering factors to change during the pulse, with a preferential `bleaching' of heavy atoms. This paper investigates the effects of electronic damage on experimental data collected from a Gd derivative of lysozyme microcrystals at different X-ray intensities, and the degree of ionization of Gd atoms is quantified from phased difference Fourier maps. A pattern sorting scheme is proposed to maximize the ionization contrast and the way in which the local electronic damage can be used for a new experimental phasing method is discussed.

  8. The risk of retina damage from high intensity light sources.

    Science.gov (United States)

    Pollak, V A; Romanchuk, K G

    1980-05-01

    The risk of thermal damage to the retina of the eye by exposure to excessive light intensities from continuous and pulsed man-made sources is discussed. The probability of injury increases, the larger the radiant power absorbed by the retina and the smaller the size of the retinal image of the source. A mehtod of estimating the temperature increase of the immediately affected area of the retina is presented. The time constants involved are also briefly considered. Using numerical values from literature for the relevant parameters of the eye, threshold values for a variety of conditions can be established. Below these values little risk of retina damage should exist. The degree of hazard when these values are exceeded depends upon the circumstances. A case study of a welding accident showed good agreement between the conclusions of the theoretical analysis and clinical findings.

  9. Transverse feedback: high intensity operation, AGC, IGC, lessons for 2012

    CERN Document Server

    Höfle, W

    2012-01-01

    The transverse damper system (ADT) plays an important role in the preservation of the beam transverse emittance and for damping of oscillations driven by the coupled bunch instability. An overview of the ADT system will be presented with an emphasis on the important feedback loop parameters as they change from injection through the ramp into collision. The dedicated setting - up procedure required for the different bunch intensities and bunch spacings will be explained. During the 2011 run the injection and abort gap cleaning became operational at injection energy. Preparations for cleaning at 3.5 TeV as well as batch selective transverse blow - up were completed and preliminarily tested. Plans for 2012 include study and potential improvement of the system impulse response to improve the 'selectivity' of the cleaning and blow - up facility. The ADT also provides bunch - by - bunch observation, which was extensively used during the run and MDs, and will be further upgraded during the next year.

  10. Futurism.

    Science.gov (United States)

    Foy, Jane Loring

    The objectives of this research report are to gain insight into the main problems of the future and to ascertain the attitudes that the general population has toward the treatment of these problems. In the first section of this report the future is explored socially, psychologically, and environmentally. The second section describes the techniques…

  11. A Pilot Study Investigating the Potential of High-Intensity Focused Ultrasound to Treat Tumours Rapidly

    Science.gov (United States)

    Cranston, Jonathan M.; Rivens, Ian; ter Haar, Gail; Kennedy, James

    2007-05-01

    The aim of this project was to investigate the possibility of rapid tumour destruction by a novel method of treating the periphery of a tumour and inducing ischemia by impeding the blood supply. Ex vivo experiments were initially carried out in bovine liver to determine the optimum conditions for focal depth, gantry transducer speed circle diameter and intensity of the ultrasound beam. In vivo experiments were then performed in PGV rat livers implanted with a HSN fibrosarcoma cell line. The tumours were treated by novel technique of creating an annular lesion around the perimeter of the tumour. Macroscopic and microscopic examination of the lesion at post mortem was performed. In addition histological examination of the untreated tumour which was within the annular circle of treatment was examined. This showed evidence of karyolytic nuclei a week after treatment suggesting death by infarction within this area. There was also some evidence of endothelial damage in the blood vessels with fragmented nuclei visible in the lumen. The work presented here adds to our understanding of how high intensity focused ultrasound may be used to treat tumours in as faster and more efficient way. Further work in this area will facilitate the design of future therapeutic interventions in the medical and veterinary world.

  12. High intensity focused ultrasound technology, its scope and applications in therapy and drug delivery.

    Science.gov (United States)

    Phenix, Christopher Peter; Togtema, Melissa; Pichardo, Samuel; Zehbe, Ingeborg; Curiel, Laura

    2014-01-01

    Ultrasonography is a safe, inexpensive and wide-spread diagnostic tool capable of producing real-time non-invasive images without significant biological effects. However, the propagation of higher energy, intensity and frequency ultrasound waves through living tissues can induce thermal, mechanical and chemical effects useful for a variety of therapeutic applications. With the recent development of clinically approved High Intensity Focused Ultrasound (HIFU) systems, therapeutic ultrasound is now a medical reality. Indeed, HIFU has been used for the thermal ablation of pathological lesions; localized, minimally invasive ultrasound-mediated drug delivery through the transient formation of pores on cell membranes; the temporary disruption of skin and the blood brain barrier; the ultrasound induced break-down of blood clots; and the targeted release of drugs using ultrasound and temperature sensitive drug carriers. This review seeks to engage the pharmaceutical research community by providing an overview on the biological effects of ultrasound as well as highlighting important therapeutic applications, current deficiencies and future directions.

  13. Set up of an innovative methodology to measure on-line the incineration potential of minor actinides under very high neutron sources in the frame of the future prospects of the nuclear waste transmutation; Mise au point d'une methodologie innovante pour la mesure du potentiel d'incineration d'actinides mineurs sous des sources tres intenses de neutrons, dans la perspective de transmutation des dechets nucleaires

    Energy Technology Data Exchange (ETDEWEB)

    Fadil, M

    2003-03-01

    This work deals generally with the problem of nuclear waste management and especially with the transmutation of it to reduce considerably its radiotoxicity potential. The principal objective of this thesis is to show the feasibility to measure on-line the incineration potential of minor actinides irradiated under very high neutron flux. To realize this goal, we have developed fission micro-chambers able to operate, for the first time in the world, in saturation regime under a severe neutron flux. These new chambers use {sup 235}U as an active deposit. They were irradiated in the high flux reactor at Laue-Langevin Institute in Grenoble. The measurement of the saturation current delivered by these chambers during their irradiation for 26 days allowed to evaluate the burn-up of {sup 235}U. We have determined the neutron flux intensity of 1,6 10{sup 15} n.cm{sup -2}.s{sup -1} in the bottom of the irradiation tube called 'V4'. The relative uncertainty of this value is less than 4 %. This is for the first time that such high neutron flux is measured with a fission chamber. To confirm this result, we have also performed independent measurements using gamma spectroscopy of irradiated Nb and Co samples. Both results are in agreement within error bars. Simple Deposit Fission Chambers (SDFC) as above were the reference of the new generation of fission chambers that we have developed in the framework of this thesis: Double Deposit Fission Chambers (DDFC). The reference active deposit was {sup 235}U. The other deposit was the actinide that we wanted to study (e.g. {sup 237}Np and {sup 241}Am). At the end of the thesis, we present some suggestions to ameliorate the operation of the DDFC to be exploited in other transmutation applications in the future. (author)

  14. Crystal Ball: On the Future High Energy Colliders

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, Vladimir [Fermilab

    2015-09-20

    High energy particle colliders have been in the forefront of particle physics for more than three decades. At present the near term US, European and international strategies of the particle physics community are centered on full exploitation of the physics potential of the Large Hadron Collider (LHC) through its high-luminosity upgrade (HL-LHC). A number of next generation collider facilities have been proposed and are currently under consideration for the medium- and far-future of the accelerator-based high energy physics. In this paper we offer a uniform approach to evaluation of various accelerators based on the feasibility of their energy reach, performance reach and cost range. We briefly review such post-LHC options as linear e+e- colliders in Japan (ILC) or at CERN (CLIC), muon collider, and circular lepton or hadron colliders in China (CepC/SppC) and Europe (FCC). We conclude with a look into ultimate energy reach accelerators based on plasmas and crystals, and some perspectives for the far future of accelerator-based particle physics.

  15. Crystal Ball: On the Future High Energy Colliders

    CERN Document Server

    Shiltsev, Vladimir

    2015-01-01

    High energy particle colliders have been in the forefront of particle physics for more than three decades. At present the near term US, European and international strategies of the particle physics community are centered on full exploitation of the physics potential of the Large Hadron Collider (LHC) through its high-luminosity upgrade (HL-LHC). A number of next generation collider facilities have been proposed and are currently under consideration for the medium- and far-future of the accelerator-based high energy physics. In this paper we offer a uniform approach to evaluation of various accelerators based on the feasibility of their energy reach, performance reach and cost range. We briefly review such post-LHC options as linear e+e- colliders in Japan (ILC) or at CERN (CLIC), muon collider, and circular lepton or hadron colliders in China (CepC/SppC) and Europe (FCC). We conclude with a look into ultimate energy reach accelerators based on plasmas and crystals, and some perspectives for the far future of ...

  16. High-intensity training reduces CD8+ T-cell redistribution in response to exercise

    NARCIS (Netherlands)

    Witard, O.C.; Turner, J.E.; Jackman, S.R.; Tipton, K.D.; Jeukendrup, A.E.; Kies, A.K.; Bosch, J.A.

    2012-01-01

    Purpose: We examined whether exercise-induced lymphocytosis and lymphocytopenia are impaired with high-intensity training. Methods: Eight trained cyclists (V·O2max = 64.2 ± 6.5 mL·kg-1·min-1) undertook 1 wk of normal-intensity training and a second week of high-intensity training. On day 7 of each w

  17. Moderate intensity, but not high intensity, treadmill exercise training alters power output properties in myocardium from aged rats.

    Science.gov (United States)

    Chung, Eunhee; Diffee, Gary M

    2012-11-01

    Aging is characterized by a progressive decline in cardiac function, but endurance exercise training has been shown to retard a number of deleterious effects of aging. However, underlying mechanisms by which exercise training improves age-related decrements in myocardial contractile function are not well understood. The purpose of this study was to determine the effects of exercise training on power output properties in permeablized (skinned) myocytes of old rats. Thirty-month-old rats were divided into sedentary control (C) and groups undergoing 11 weeks of treadmill exercise training at moderate intensity (MI) and at high intensity (HI). Peak power output normalized to maximal force was significantly increased in MI but not in HI compared to C with significant increases in atrial myosin light chain 1 in ventricle. These results suggest that MI exercise training is beneficial as a significant increase was seen in the ability of the myocardium to do work, but this effect was not seen with HI training.

  18. Metabolic responses to high protein diet in Korean elite bodybuilders with high-intensity resistance exercise

    Directory of Open Access Journals (Sweden)

    Choue Ryowon

    2011-07-01

    Full Text Available Abstract Background High protein diet has been known to cause metabolic acidosis, which is manifested by increased urinary excretion of nitrogen and calcium. Bodybuilders habitually consumed excessive dietary protein over the amounts recommended for them to promote muscle mass accretion. This study investigated the metabolic response to high protein consumption in the elite bodybuilders. Methods Eight elite Korean bodybuilders within the age from 18 to 25, mean age 21.5 ± 2.6. For data collection, anthropometry, blood and urinary analysis, and dietary assessment were conducted. Results They consumed large amounts of protein (4.3 ± 1.2 g/kg BW/day and calories (5,621.7 ± 1,354.7 kcal/day, as well as more than the recommended amounts of vitamins and minerals, including potassium and calcium. Serum creatinine (1.3 ± 0.1 mg/dl and potassium (5.9 ± 0.8 mmol/L, and urinary urea nitrogen (24.7 ± 9.5 mg/dl and creatinine (2.3 ± 0.7 mg/dl were observed to be higher than the normal reference ranges. Urinary calcium (0.3 ± 0.1 mg/dl, and phosphorus (1.3 ± 0.4 mg/dl were on the border of upper limit of the reference range and the urine pH was in normal range. Conclusions Increased urinary excretion of urea nitrogen and creatinine might be due to the high rates of protein metabolism that follow high protein intake and muscle turnover. The obvious evidence of metabolic acidosis in response to high protein diet in the subjects with high potassium intake and intensive resistance exercise were not shown in this study results. However, this study implied that resistance exercise with adequate mineral supplementation, such as potassium and calcium, could reduce or offset the negative effects of protein-generated metabolic changes. This study provides preliminary information of metabolic response to high protein intake in bodybuilders who engaged in high-intensity resistance exercise. Further studies will be needed to determine the effects of the intensity

  19. High Resolution Projection of Future Air Quality in South Asia

    Science.gov (United States)

    Kumar, R.; Barth, M. C.; Pfister, G.; Lamarque, J. F.; Walters, S.; Naja, M. K.; Ghude, S. D.

    2015-12-01

    About one seventh of the world's population living in South Asia faces the risk of severe air pollution due to high anthropogenic emissions of air pollutants. Recent studies have shown that exposure to present day air pollution in South Asia is sufficient enough to reduce the lifespan of about 660 million people by about 3 years, destroy food that can feed about 94 million poor people and cause economic loss of several billion dollars. This problem may worsen in the future as anthropogenic emissions are expected to increase due to rapid economic growth in South Asia, and climate change is expected to lead to atmospheric conditions conducive for the production and accumulation of air pollutants. In order to predict how air quality will change in South Asia in future (2050), we are conducting high resolution air quality simulations for the present day (2005-2014) and future (2046-2055) time periods using the Nested Regional Climate Model coupled with Chemistry (NRCM-Chem). The model domain covers entire South Asia at a horizontal grid spacing of 60 km with a nested domain over the densely populated and polluted Indo-Gangetic Plain region at a horizontal grid spacing of 12 km. The model results are being evaluated with available in situ and satellite based observations and the evaluation results show that NRCM-Chem model is able to capture several important features of the observed spatial and temporal distribution of key meteorological parameters and air pollutants. Initial model results show that annual average surface ozone and PM2.5 concentrations may increase by up to 15 ppbv and 25 μg m-3, respectively with highest increase in the Indo-Gangetic Plain.

  20. [Reflected high-intensity motion signals as markers of left ventricular diastolic dysfunction].

    Science.gov (United States)

    Makarenko, E S

    2013-01-01

    Reflected high-intensity signals of left ventricular motion can be used for assessment of diastolic function of left ventricle. There are many correlations between reflected high-intensity signals, transmitral flow, and tissue Doppler imaging parameters. Diagnostic criteria of LV diastolic dysfunction based on measurement of LV motion are suggested.

  1. The influence of basketball dribbling on repeated high-intensity intermittent runs

    Directory of Open Access Journals (Sweden)

    Zhaowei Kong

    2015-12-01

    Conclusion: The results suggest that the Yo-Yo IE2 test could reflect the repeatability of high-intensity intermittent basketball dribbling performance, while dribbling skills may have different influences on high-intensity intermittent exercise capacity in adolescent players at different ages.

  2. Refinement of Eutectic Silicon Phase of Aluminum A356 Alloy Using High-Intensity Ultrasonic Vibration

    Energy Technology Data Exchange (ETDEWEB)

    Jian, Xiaogang [ORNL; Han, Qingyou [ORNL

    2006-01-01

    The eutectic silicon in A356 alloy can be refined and modified using either chemical, quench, or superheating modification. We observed, for the first time, that the eutectic silicon can also be significantly refined using high-intensity ultrasonic vibration. Rosette-like eutectic silicon is formed during solidification of specimen treated with high-intensity ultrasonic vibration.

  3. The study towards high intensity high charge state laser ion sources.

    Science.gov (United States)

    Zhao, H Y; Jin, Q Y; Sha, S; Zhang, J J; Li, Z M; Liu, W; Sun, L T; Zhang, X Z; Zhao, H W

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  4. The study towards high intensity high charge state laser ion sources

    Science.gov (United States)

    Zhao, H. Y.; Jin, Q. Y.; Sha, S.; Zhang, J. J.; Li, Z. M.; Liu, W.; Sun, L. T.; Zhang, X. Z.; Zhao, H. W.

    2014-02-01

    As one of the candidate ion sources for a planned project, the High Intensity heavy-ion Accelerator Facility, a laser ion source has been being intensively studied at the Institute of Modern Physics in the past two years. The charge state distributions of ions produced by irradiating a pulsed 3 J/8 ns Nd:YAG laser on solid targets of a wide range of elements (C, Al, Ti, Ni, Ag, Ta, and Pb) were measured with an electrostatic ion analyzer spectrometer, which indicates that highly charged ions could be generated from low-to-medium mass elements with the present laser system, while the charge state distributions for high mass elements were relatively low. The shot-to-shot stability of ion pulses was monitored with a Faraday cup for carbon target. The fluctuations within ±2.5% for the peak current and total charge and ±6% for pulse duration were demonstrated with the present setup of the laser ion source, the suppression of which is still possible.

  5. Extracorporeal High-Intensity Focused Ultrasound Treatment for Breast Cancer

    Institute of Scientific and Technical Information of China (English)

    HuiZhu; FengWu; WenzhiChen; YoudeCao; JinBai; ZhibiaoWang

    2004-01-01

    OBJECTIVE To evaluate the clinical safety and efficacy of using highintensity focused ultrasound (HIFU) therapy, for breast cancer, and to select the appropriate methods in evaluating the therapeutic effects.METHODS A total of 24 patients with breast cancer underwent HIFU treatment 1-2 weeks before receiving modified radical mastectomy. During and after HIFU therapy, changes in blood pressure, breath, pulse and peripheral blood oxygen saturation were monitored. At the same time, the damage of the skin and tissue produced by HIFU at the target region was evaluated as well. Surgically excised samples were used for pathological examinations to evaluate the HIFU-induced destruction of the targeted tissue. Three patients received Tc-ECT and 1 MRI examinations before and after HIFU.RESULTS HIFU treatment had no apparent influence on either the tissue nearby the target or on vital signs of the patients. Pathological, tc-ECT and MRI examinations demonstrated that targeted tissue showed complete coagulative necrosis.CONCLUSION Under the guidance of real-time ultrasonic imaging, HIFU can effectively and safely destroy the breast cancer mass and 99MTc-ECT and MRI examination can be utilized to evaluate the therapeutic effects.HIFU may become one of the options for breast cancer therapy in the future.

  6. Rewriting the rules governing high intensity interactions of light with matter

    Science.gov (United States)

    Borisov, Alex B.; McCorkindale, John C.; Poopalasingam, Sankar; Longworth, James W.; Simon, Peter; Szatmári, Sándor; Rhodes, Charles K.

    2016-04-01

    The trajectory of discovery associated with the study of high-intensity nonlinear radiative interactions with matter and corresponding nonlinear modes of electromagnetic propagation through material that have been conducted over the last 50 years can be presented as a landscape in the intensity/quantum energy [I-ħω] plane. Based on an extensive series of experimental and theoretical findings, a universal zone of anomalous enhanced electromagnetic coupling, designated as the fundamental nonlinear domain, can be defined. Since the lower boundaries of this region for all atomic matter correspond to ħω ~ 103 eV and I  ≈  1016 W cm-2, it heralds a future dominated by x-ray and γ-ray studies of all phases of matter including nuclear states. The augmented strength of the interaction with materials can be generally expressed as an increase in the basic electromagnetic coupling constant in which the fine structure constant α  →  Z 2 α, where Z denotes the number of electrons participating in an ordered response to the driving field. Since radiative conditions strongly favoring the development of this enhanced electromagnetic coupling are readily produced in self-trapped plasma channels, the processes associated with the generation of nonlinear interactions with materials stand in natural alliance with the nonlinear mechanisms that induce confined propagation. An experimental example involving the Xe (4d105s25p6) supershell for which Z  ≅  18 that falls in the specified anomalous nonlinear domain is described. This yields an effective coupling constant of Z 2 α  ≅  2.4  >  1, a magnitude comparable to the strong interaction and a value rendering as useless conventional perturbative analyses founded on an expansion in powers of α. This enhancement can be quantitatively understood as a direct consequence of the dominant role played by coherently driven multiply-excited states in the dynamics of the coupling. It is also

  7. Extremely short duration high intensity interval training substantially improves insulin action in young healthy males

    DEFF Research Database (Denmark)

    Babraj, John A; Vollaard, Niels B J; Keast, Cameron

    2009-01-01

    BACKGROUND: Traditional high volume aerobic exercise training reduces cardiovascular and metabolic disease risk but involves a substantial time commitment. Extremely low volume high-intensity interval training (HIT) has recently been demonstrated to produce improvements to aerobic function, but i...

  8. High intensity electromagnetic field gerenation using a transportable reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank

    2008-01-01

    A reverberation chamber can create very high field strength with moderate input power. Existing chambers are making use of a paddle wheel to change the resonant modes in the chamber. A transportable reverberation chamber with vibrating walls will be presented. Inside this Vibrating Intrinsic Reverbe

  9. STATUS REPORT ON DEVELOPMENT OF A HIGH-SPEED HIGH-INTENSITY MOLECULAR BEAM

    Energy Technology Data Exchange (ETDEWEB)

    Knuth, Eldon L.

    1963-07-15

    Status of a high-speed high-intensity molecular beam under development is described. Bases for designs of the several components are presented. Using an arc-heated source and a hypersonic jet, molecular energies exceeding 1 ev and beam intensities of the order of 10/sup 16/ molecules/ cm/sup 2/ sec are anticipated. A two-disk beam chopper and speed selector provides a means for analyzing the speed distribution in the generated beam, for chopping the beam into bursts of nearly monoenergetic molecules suitable for scattering studies using the time-of-flight technique, and for modulating the beam in order to facilitate detection. A through-flow ionization detector possesses the versatility required for scattering studies using the time-of-flight technique. A sorption pump and a turbo pump serve as central components of alternative pumping systems for the collimating chamber. Using the arc-heated source, the converging nozzle, the conduction-radiation-cooled skimmer, the turbo pump (turning at 3400 rpm), the chopperselector (acting only as a chopper), and the detector, an arc-heated beam is generated and detected. (auth)

  10. Intense high-quality medical proton beams via laser fields

    CERN Document Server

    Galow, Benjamin J; Keitel, Christoph H

    2010-01-01

    Simulations based on the coupled relativistic equations of motion show that protons stemming from laserplasma processes can be efficiently post-accelerated employing crossed pulsed laser beams focused to spot radii on the order of the laser wavelength. We demonstrate that the crossed beams produce quasi-monoenergetic accelerated protons with kinetic energies exceeding 200 MeV, small energy spreads of about 1% and high densities as required for hadron cancer therapy.

  11. High-intensity molecular harmonic generation without ionization

    Institute of Scientific and Technical Information of China (English)

    Wang Jun; Chen Gao; Guo Fu-Ming; Li Su-Yu; Chen Ji-Gen; Yang Yu-Jun

    2013-01-01

    We theoretically investigate high-order harmonic generation from H2+ in an infrared laser field.Our numerical simulations show that a highly efficient plateau structure exists in the molecular harmonic spectrum.Under the action of the infrared laser pulse,the bound electronic wave packet in a potential well has enough time to tunnel through the effective potential barrier,which is formed by the molecular potential and the infrared laser field,and then recombine with the neighboring nucleus emitting a harmonic photon.During the entire dynamic process,because the wave packet is mainly located in the effective potential,the diffusion effect is of no significance,and thus a highly efficient harmonic plateau can be achieved.Specifically,the cut-off frequency of the plateau is linearly scaled with the peak amplitude of the infrared laser electric field,which may open another route to examine the internuclear distance of the molecule.Furthermore,one may detect the molecular bond lengths using the harmonic plateau.

  12. A Highly intense DC muon source, MuSIC and muon CLFV search

    Science.gov (United States)

    Hino, Y.; Kuno, Y.; Sato, A.; Sakamoto, H.; Matsumoto, Y.; Tran, N. H.; Hashim, I. H.; Fukuda, M.; Hayashida, Y.; Ogitsu, T.; Yamamoto, A.; Yoshida, M.

    2014-08-01

    MuSIC is a new muon facility, which provides the world's highest intense muon beam with continuous time structure at Research Center of Nuclear Physics (RCNP), Osaka University. It's intensity is designed to be 108 muons per second with only 0.4 kW proton beam. Such a high intense muon beam is very important for searches of rare decay processes, for example search for the muon to electron conversion.

  13. A Highly intense DC muon source, MuSIC and muon CLFV search

    Energy Technology Data Exchange (ETDEWEB)

    Hino, Y.; Kuno, Y.; Sato, A. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Sakamoto, H. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Research Center of Nuclear Physics, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Matsumoto, Y.; Tran, N.H.; Hashim, I.H. [Department of Physics, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka 560-0043 (Japan); Fukuda, M.; Hayashida, Y. [Research Center of Nuclear Physics, 10-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Ogitsu, T.; Yamamoto, A.; Yoshida, M. [High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2014-08-15

    MuSIC is a new muon facility, which provides the world's highest intense muon beam with continuous time structure at Research Center of Nuclear Physics (RCNP), Osaka University. It's intensity is designed to be 10{sup 8} muons per second with only 0.4 kW proton beam. Such a high intense muon beam is very important for searches of rare decay processes, for example search for the muon to electron conversion.

  14. High-intensity drying processes-impulse drying

    Energy Technology Data Exchange (ETDEWEB)

    Orloff, D.I.

    1991-06-01

    Impulse drying is an innovative process for drying paper that holds great promise for reducing the energy consumed during the manufacture of paper and similar web products. impulse drying occurs when a wet paper web passes through a press nip in which one of the rolls is heated to a high temperature. A steam layer adjacent to the heated surface grows and displaces water from the sheet in a very efficient manner. The energy required for water removal is very much less than that required for conventional evaporative drying. To eliminate sheet delamination, low thermal mass ceramic press roll coatings were developed to reduce heat transfer to the sheet, while maintaining high heat flux during early stages of the process. In so doing, most of the transferred energy is used to form steam that displaces liquid water, rather than in excessively heating the sheet. During this period, a prototype ceramic coating was developed and its impulse drying performance was compared to that of steel surfaces. It was observed that ceramic platens can be operated at higher temperatures and pressures resulting in improved water removal and physical properties without inducing sheet delamination. Heat flux measurement techniques were developed to provide a mechanistic explanation for the superior performance of the prototype. The work confirmed that the prototype ceramic coating is more energy efficient than the steel surface.

  15. High-intensity drying processes-impulse drying. Yearly report

    Energy Technology Data Exchange (ETDEWEB)

    Orloff, D.I.

    1991-06-01

    Impulse drying is an innovative process for drying paper that holds great promise for reducing the energy consumed during the manufacture of paper and similar web products. impulse drying occurs when a wet paper web passes through a press nip in which one of the rolls is heated to a high temperature. A steam layer adjacent to the heated surface grows and displaces water from the sheet in a very efficient manner. The energy required for water removal is very much less than that required for conventional evaporative drying. To eliminate sheet delamination, low thermal mass ceramic press roll coatings were developed to reduce heat transfer to the sheet, while maintaining high heat flux during early stages of the process. In so doing, most of the transferred energy is used to form steam that displaces liquid water, rather than in excessively heating the sheet. During this period, a prototype ceramic coating was developed and its impulse drying performance was compared to that of steel surfaces. It was observed that ceramic platens can be operated at higher temperatures and pressures resulting in improved water removal and physical properties without inducing sheet delamination. Heat flux measurement techniques were developed to provide a mechanistic explanation for the superior performance of the prototype. The work confirmed that the prototype ceramic coating is more energy efficient than the steel surface.

  16. Data Intensive High Energy Physics Analysis in a Distributed Cloud

    CERN Document Server

    Sobie, R J; Anderson, M; Armstrong, P; Fransham, K; Gable, I; Harris, D; Leavett-Brown, C; Paterson, M; Penfold-Brown, D; Vliet, M; Charbonneau, A; Impey, R; Podaima, W

    2011-01-01

    We show that distributed Infrastructure-as-a-Service (IaaS) compute clouds can be effectively used for the analysis of high energy physics data. We have designed a distributed cloud system that works with any application using large input data sets requiring a high throughput computing environment. The system uses IaaS-enabled science and commercial clusters in Canada and the United States. We describe the process in which a user prepares an analysis virtual machine (VM) and submits batch jobs to a central scheduler. The system boots the user-specific VM on one of the IaaS clouds, runs the jobs and returns the output to the user. The user application accesses a central database for calibration data during the execution of the application. Similarly, the data is located in a central location and streamed by the running application. The system can easily run one hundred simultaneous jobs in an efficient manner and should scale to many hundreds and possibly thousands of user jobs.

  17. Relative Match Intensities at High Altitude in Highly-Trained Young Soccer Players (ISA3600

    Directory of Open Access Journals (Sweden)

    Martin Buchheit

    2015-03-01

    Full Text Available To compare relative match intensities of sea-level versus high-altitude native soccer players during a 2-week camp at 3600 m, data from 7 sea-level (Australian U17 National team, AUS and 6 high-altitude (a Bolivian U18 team, BOL native soccer players were analysed. Two matches were played at sea-level and three at 3600 m on Days 1, 6 and 13. The Yo-Yo Intermittent recovery test (vYo-YoIR1 was performed at sea-level, and on Days 3 and 10. Match activity profiles were measured via 10-Hz GPS. Distance covered >14.4 km.h-1 (D>14.4 km·h-1 and >80% of vYo-YoIR1 (D>80%vYo-YoIR1 were examined. Upon arrival at altitude, there was a greater decrement in vYo-YoIR1 (Cohen’s d +1.0, 90%CL ± 0.8 and D>14.4 km·h-1 (+0.5 ± 0.8 in AUS. D>14.4 km.h-1 was similarly reduced relative to vYo-YoIR1 in both groups, so that D>80%vYo-YoIR1 remained similarly unchanged (-0.1 ± 0.8. Throughout the altitude sojourn, vYo-YoIR1 and D>14.4 km·h-1 increased in parallel in AUS, so that D>80%vYo-YoIR1 remained stable in AUS (+6.0%/match, 90%CL ± 6.7; conversely D>80%vYo-YoIR1 decreased largely in BOL (-12.2%/match ± 6.2. In sea-level natives competing at high-altitude, changes in match running performance likely follow those in high-intensity running performance. Bolivian data confirm that increases in ‘fitness’ do not necessarily translate into greater match running performance, but rather in reduced relative exercise intensity.

  18. EFFECT OF HIGH & LOW INTENSITIES OF AEROBIC EXERCISE ON PHYSICAL FITNESS INDEX

    Directory of Open Access Journals (Sweden)

    Madhusudhan

    2015-06-01

    Full Text Available BACKGROUND: Aerobic exercise reduces body fat and improves weight control, increases HDL&Vo2 max. Also improves PFI (physical fitness index which is defined as ability to carry out daily tasks with vigour and alertness without undue fatigue. Though aerobic exercise is found to improve physical fitness, the relative merits of different intensities of aerobi c exercise in improving physical fitness is still uncertain. AIM: The present study was conducted to know the Effect of High & low intensity aerobic training on physical fitness index. MATERIALS & METHODS : 80 sedentary men (18 - 40 years were randomized in to 2 equal groups (High Intensity & low intensity group . The High [80% HR max] & Low intensity [50 % HR max] groups underwent aerobic exercise training using Bicycle ergo meter (COSCO at 900kpm & 540kpm, for 15mins/day & 30mins/day respectively, 5days a week, for a period of 14weeks. Physical fitness index of each subject was recorded by Modified Harvard step test before & after intervention. RESULTS : After 14 weeks of aerobic training both the exercise groups had improvement in PFI, but high intensity gr oup had a significant (p<0.05 improvement in PFI (97.18 - 101.14 than low intensity group (98.12 - 100.6. CONCLUSION : High intensity aerobic exercise is effective in improving physical fitness.

  19. High-protein diet induces oxidative stress in rat brain: protective action of high-intensity exercise against lipid peroxidation

    OpenAIRE

    Camiletti-Moir??n, Daniel; Aparicio Garc??a-Molina, Virginia A.; Nebot Valenzuela, Elena; Medina, Gerardo; Mart??nez, Rosario; Kapravelou, Garyfallia; Andrade, Ana; Porres-Foulquie, Jes??s; L??pez-Jurado, Mar??a; Aranda Ram??rez, Pilar

    2015-01-01

    diets as well as aerobic exercise could promote antioxidant capacity and consequently reduce free radicals overproduction on brain. However, little is know regarding to the high-protein diets and high intensity exercise on oxidative stress production. The aim of this study was to analyse the effects of high-protein diets and high-intensity exercise (HIE) on brain oxidative stress markers. Materials and Methods: A total of 40 male Wistar rats were randomly distributed i...

  20. Tools and techniques for estimating high intensity RF effects

    Science.gov (United States)

    Zacharias, Richard L.; Pennock, Steve T.; Poggio, Andrew J.; Ray, Scott L.

    1992-01-01

    Tools and techniques for estimating and measuring coupling and component disturbance for avionics and electronic controls are described. A finite-difference-time-domain (FD-TD) modeling code, TSAR, used to predict coupling is described. This code can quickly generate a mesh model to represent the test object. Some recent applications as well as the advantages and limitations of using such a code are described. Facilities and techniques for making low-power coupling measurements and for making direct injection test measurements of device disturbance are also described. Some scaling laws for coupling and device effects are presented. A method for extrapolating these low-power test results to high-power full-system effects are presented.

  1. Generating long sequences of high-intensity femtosecond pulses

    CERN Document Server

    Bitter, Martin

    2015-01-01

    We present an approach to create pulse sequences extending beyond 150~picoseconds in duration, comprised of $100~\\mu$J femtosecond pulses. A quarter of the pulse train is produced by a high-resolution pulse shaper, which allows full controllability over the timing of each pulse. Two nested Michelson interferometers follow to quadruple the pulse number and the sequence duration. To boost the pulse energy, the long train is sent through a multi-pass Ti:Sapphire amplifier, followed by an external compressor. A periodic sequence of 84~pulses of 120~fs width and an average pulse energy of 107~$\\mu$J, separated by 2~ps, is demonstrated as a proof of principle.

  2. Study of a final focus system for high intensity beams

    Energy Technology Data Exchange (ETDEWEB)

    Henestroza, Enrique; Eylon, Shmuel; Roy, Prabir K.; Yu, Simon S.; Bieniosek, Frank M.; Shuman, Derek B.; Waldron, William L.

    2004-06-01

    The NTX experiment at the Heavy Ion Fusion Virtual National Laboratory is exploring the performance of neutralized final focus systems for high perveance heavy ion beams. The final focus scenario in an HIF driver consists of several large aperture quadrupole magnets followed by a drift section in which the beam space charge is neutralized by a plasma. This beam is required to hit a millimeter-sized target spot at the end of the drift section. The objective of the NTX experiments and associated theory and simulations is to study the various physical mechanisms that determine the final spot size (radius r{sub s}) at a given distance (f) from the end of the last quadrupole. In a fusion driver, f is the standoff distance required to keep the chamber wall and superconducting magnets properly protected. The NTX final quadrupole focusing system produces a converging beam at the entrance to the neutralized drift section where it focuses to a small spot. The final spot is determined by the conditions of the beam entering the quadrupole section, the beam dynamics in the magnetic lattice, and the plasma neutralization dynamics in the drift section. The main issues are the control of emittance growth due to high order fields from magnetic multipoles and image fields. In this paper, we will describe the theoretical and experimental aspects of the beam dynamics in the quadrupole lattice, and how these physical effects influence the final beam size. In particular, we present theoretical and experimental results on the dependence of final spot size on geometric aberrations and perveance.

  3. Impact of High-intensity Intermittent and Moderate-intensity Continuous Exercise on Autonomic Modulation in Young Men.

    Science.gov (United States)

    Cabral-Santos, C; Giacon, T R; Campos, E Z; Gerosa-Neto, J; Rodrigues, B; Vanderlei, L C M; Lira, F S

    2016-06-01

    The aim of this study was to compare heart rate variability (HRV) recovery after two iso-volume (5 km) exercises performed at different intensities. 14 subjects volunteered (25.17±5.08 years; 74.7±6.28 kg; 175±0.05 cm; 59.56±5.15 mL·kg(-1)·min(-1)) and after determination of peak oxygen uptake (VO2Peak) and the speed associated with VO2Peak (sVO2Peak), the subjects completed 2 random experimental trials: high-intensity exercise (HIE - 1:1 at 100% sVO2Peak), and moderate-intensity continuous exercise (MIE - 70% sVO2Peak). HRV and RR intervals were monitored before, during and after the exercise sessions together with, the HRV analysis in the frequency domains (high-frequency - HF: 0.15 to 0.4 Hz and low-frequency - LF: 0.04 to 0.15 Hz components) and the ratio between them (LF/HF). Statistical analysis comparisons between moments and between HIE and MIE were performed using a mixed model. Both exercise sessions modified LFlog, HFlog, and LF/HF (F=16.54, F=19.32 and F=5.17, p<0.05, respectively). A group effect was also found for LFlog (F=23.91, p<0.05), and HFlog (F=57.55, p< 0.05). LF/HF returned to resting value 15 min after MIE exercise and 20 min after HIE exercise. This means that the heavy domain (aerobic and anaerobic threshold) induces dissimilar autonomic modification in physically active subjects. Both HIE and MIE modify HRV, and generally HIE delays parasympathetic autonomic modulation recovery after iso-volume exercise.

  4. Effect of preseason concurrent muscular strength and high-intensity interval training in professional soccer players.

    Science.gov (United States)

    Wong, Pui-lam; Chaouachi, Anis; Chamari, Karim; Dellal, Alexandre; Wisloff, Ulrik

    2010-03-01

    This study examined the effect of concurrent muscular strength and high-intensity running interval training on professional soccer players' explosive performances and aerobic endurance. Thirty-nine players participated in the study, where both the experimental group (EG, n = 20) and control group (CG, n = 19) participated in 8 weeks of regular soccer training, with the EG receiving additional muscular strength and high-intensity interval training twice per week throughout. Muscular strength training consisted of 4 sets of 6RM (repetition maximum) of high-pull, jump squat, bench press, back half squat, and chin-up exercises. The high-intensity interval training consisted of 16 intervals each of 15-second sprints at 120% of individual maximal aerobic speed interspersed with 15 seconds of rest. EG significantly increased (p aerobic speed test, and maximal aerobic speed. High-intensity interval running can be concurrently performed with high load muscular strength training to enhance soccer players' explosive performances and aerobic endurance.

  5. Improvement of high-voltage staircase drive circuit waveform for high-intensity therapeutic ultrasound

    Science.gov (United States)

    Tamano, Satoshi; Jimbo, Hayato; Azuma, Takashi; Yoshizawa, Shin; Fujiwara, Keisuke; Itani, Kazunori; Umemura, Shin-Ichiro

    2016-07-01

    Recently, in the treatment of diseases such as cancer, noninvasive or low-invasive modality, such as high-intensity focused ultrasound (HIFU), has been put into practice as an alternative to open surgery. HIFU induces thermal ablation of the target tissue to be treated. To improve the efficiency of HIFU, we have proposed a “triggered-HIFU” technique, which uses the combination of a short-duration, high-voltage transmission and a long-duration, medium-voltage transmission. In this method, the transmission device must endure high peak voltage for the former and the high time-average power for the latter. The triggered-HIFU sequence requires electronic scanning of the HIFU focus to maximize its thermal efficiency. Therefore, the transmission device must drive an array transducer with the number of elements on the order of a hundred or more, which requires that each part of the device that drives each element must be compact. The purpose of this work is to propose and construct such a transmission device by improving the staircase drive circuit, which we previously proposed. The main point of improvement is that both N and P MOSFETs are provided for each staircase voltage level instead of only one of them. Compared with the previous ultrasonic transmission circuit, high-voltage spikes were significantly reduced, the power consumption was decreased by 26.7%, and the transmission circuit temperature rise was decreased by 14.5 °C in the triggered-HIFU heating mode.

  6. High-intensity intermittent swimming improves cardiovascular health status for women with mild hypertension

    DEFF Research Database (Denmark)

    Mohr, Magni; Nordsborg, Nikolai Baastrup; Lindenskov, Annika;

    2014-01-01

    To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n = 21; HIT), moderate-intensity (n = 21; MOD), and control groups (n = 20; CON). HIT...... performed 6-10 × 30 s all-out swimming interspersed by 2 min recovery and MOD swam continuously for 1 h at moderate intensity for a 15-week period completing in total 44 ± 1 and 43 ± 1 sessions, respectively. In CON, all measured variables were similar before and after the intervention period. Systolic BP...... swim (13 ± 3% and 22 ± 3%), interval swimming (23 ± 3% and 8 ± 3%), and Yo-Yo IE1 running performance (58 ± 5% and 45 ± 4%). In conclusion, high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance...

  7. Effect of high-intensity training on endothelial function in patients with cardiovascular and cerebrovascular disease

    DEFF Research Database (Denmark)

    Kolmos, Mia; Krawcyk, Rikke Steen; Kruuse, Christina

    2016-01-01

    OBJECTIVES: Exercise improves endothelial dysfunction, the key manifestation of cardiovascular and cerebrovascular disease, and is recommended in both cardiovascular and cerebrovascular rehabilitation. Disagreement remains, however, on the role of intensity of exercise. The purpose of this review...... was to gather current knowledge on the effects of high-intensity training versus moderate-intensity continuous exercise on endothelial function in cardiovascular and cerebrovascular patients. METHODS: A systematic review was performed in PubMed database, Embase and Cochrane libraries and on PEDro using...... the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies were restricted to cardiovascular and cerebrovascular patients, and healthy subjects as general reference. Interventions comprised of high-intensity training alone, high-intensity training compared to moderate...

  8. The Workplace of the Future: Insights from Futures Scenarios and Today's High Performance Workplaces.

    Science.gov (United States)

    Curtain, Richard

    1998-01-01

    Studies of the workplace of the future that used scenario-planning methodology and survey data suggest that nonmarket organizations will provide stability for temporary workers and result in the emergence of networks. Survey data suggest that future workplaces will foster intellectual capital through research and development. (JOW)

  9. Short-term effects of implemented high intensity shoulder elevation during computer work

    Directory of Open Access Journals (Sweden)

    Madeleine Pascal

    2009-08-01

    Full Text Available Abstract Background Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction on productivity, RPE and upper trapezius activity and rest during computer work and a subsequent pause from computer work. Methods 18 female computer workers performed 2 sessions of 15 min standardized computer mouse work preceded by 1 min pause with and without prior high intensity contraction of shoulder elevation. RPE was reported, productivity (drawings per min measured, and bipolar surface electromyography (EMG recorded from the dominant upper trapezius during pauses and sessions of computer work. Repeated measure ANOVA with Bonferroni corrected post-hoc tests was applied for the statistical analyses. Results The main findings were that a high intensity shoulder elevation did not modify RPE, productivity or EMG activity of the upper trapezius during the subsequent pause and computer work. However, the high intensity contraction reduced the relative rest time of the uppermost (clavicular trapezius part during the subsequent pause from computer work (p Conclusion Since a preceding high intensity shoulder elevation did not impose a negative impact on perceived effort, productivity or upper trapezius activity during computer work, implementation of high intensity contraction during computer work to prevent neck-shoulder pain may be possible without affecting the working routines. However, the unexpected reduction in clavicular trapezius rest during a

  10. High-intensity interval versus moderate-intensity continuous training: Superior metabolic benefits in diet-induced obesity mice.

    Science.gov (United States)

    Wang, Ningning; Liu, Yang; Ma, Yanan; Wen, Deliang

    2017-08-23

    Exercise is beneficial in obesity, however, the debate about the value of high-intensity interval training (HIIT) vs. moderate-intensity continuous training (MICT) has been long lasting. Therefore, here we have compared the possible beneficial effects of two different exercise training regimes in a mouse model of diet-induced obesity (DIO). Following 7wk. on high fat diet (HFD), ten-week-old male ICR mice (n=30) were assigned to HIIT, distance-matched MICT or remained sedentary for the next 8 constitutive weeks while maintaining the dietary treatments. Age-matched sedentary mice with standard diet were used as a control (n=10). Exercise was performed on a motorized treadmill for 5days a week. Both modes of exercise ameliorated adiposity and related metabolic dysfunction induced by HFD and sedentary lifestyle, while mice following HIIT exhibited significantly lower body weight, percentage of fat mass and smaller adipocyte size. HIIT was more favorable in preventing liver lipid accumulation by restoring mRNA levels of genes involved in hepatic lipogenesis (SREBP1, ACC1, FAS) and β-oxidation (PPARα, CPT1a, HAD). In addition, HIIT was more efficient in mitigating adipose tissue inflammation and insulin insensitivity, partly dependent on abrogating phosphorylation of JNK/IRS1 (Ser307) pathway. Moreover, only HIIT led to pronounced beige adipocyte recruitment in inguinal subcutaneous adipose tissue. We conclude that HIIT contribute a more favorable regulation of metabolic dysfunctions in DIO mice compared with MICT. Copyright © 2017. Published by Elsevier Inc.

  11. A High Intensity Linac for the National Spallation Neutron Source

    Science.gov (United States)

    Jason, A.; Bhatia, T.; Billen, J.; Schrage, D.; Kurennoy, S.; Krawczyk, F.; Lynch, M.; Nath, S.; Shafer, R.; Takeda, H.; Tallerico, P.; Wangler, T.; Wood, R.; Young, L.; Grand, P.; McKenzie-Wilson, R.

    1997-05-01

    The National Spallation Neutron Source to be constructed at Oak Ridge National Laboratory, requires a linac capable of delivering up to 5 MW of beam power to an accumulator ring with a nominal 6.2% duty factor and an energy of 1 GeV. Los Alamos, responsible for the linac design, has developed an appropriate room-temperature linac that consists of a drift-tube section from 2.5 to 20 MeV, a coupled-cavity drift-tube section to 100 MeV, and a coupled-cavity section to 1 GeV. The initial scenario requires an average 1.1-mA beam current with a corresponding 28 mA peak current and a 1.2-Mhz chopped time structure corresponding to the ring period. Upgrade to a 4.4 mA average current requires funneling with a peak current of 112 mA in the high-energy sections. Further parameters are presented along with beam dynamics and structure choices and mechanical and rf engineering considerations.

  12. Diffraction Gratings for High-Intensity Laser Applications

    Energy Technology Data Exchange (ETDEWEB)

    Britten, J

    2008-01-23

    The scattering of light into wavelength-dependent discrete directions (orders) by a device exhibiting a periodic modulation of a physical attribute on a spatial scale similar to the wavelength of light has been the subject of study for over 200 years. Such a device is called a diffraction grating. Practical applications of diffraction gratings, mainly for spectroscopy, have been around for over 100 years. The importance of diffraction gratings in spectroscopy for the measurement of myriad properties of matter can hardly be overestimated. Since the advent of coherent light sources (lasers) in the 1960's, applications of diffraction gratings in spectroscopy have further exploded. Lasers have opened a vast application space for gratings, and apace, gratings have enabled entirely new classes of laser systems. Excellent reviews of the history, fundamental properties, applications and manufacturing techniques of diffraction gratings up to the time of their publication can be found in the books by Hutley (1) and more recently Loewen and Popov (2). The limited scope of this chapter can hardly do justice to such a comprehensive subject, so the focus here will be narrowly limited to characteristics required for gratings suitable for high-power laser applications, and methods to fabricate them. A particular area of emphasis will be on maximally-efficient large-aperture gratings for short-pulse laser generation.

  13. High Performance Data Transfer for Distributed Data Intensive Sciences

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Chin [Zettar Inc., Mountain View, CA (United States); Cottrell, R ' Les' A. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Hanushevsky, Andrew B. [SLAC National Accelerator Lab., Menlo Park, CA (United States); Kroeger, Wilko [SLAC National Accelerator Lab., Menlo Park, CA (United States); Yang, Wei [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2017-03-06

    We report on the development of ZX software providing high performance data transfer and encryption. The design scales in: computation power, network interfaces, and IOPS while carefully balancing the available resources. Two U.S. patent-pending algorithms help tackle data sets containing lots of small files and very large files, and provide insensitivity to network latency. It has a cluster-oriented architecture, using peer-to-peer technologies to ease deployment, operation, usage, and resource discovery. Its unique optimizations enable effective use of flash memory. Using a pair of existing data transfer nodes at SLAC and NERSC, we compared its performance to that of bbcp and GridFTP and determined that they were comparable. With a proof of concept created using two four-node clusters with multiple distributed multi-core CPUs, network interfaces and flash memory, we achieved 155Gbps memory-to-memory over a 2x100Gbps link aggregated channel and 70Gbps file-to-file with encryption over a 5000 mile 100Gbps link.

  14. A 3 GHz photoelectron gun for high beam intensity

    CERN Document Server

    Bossart, Rudolf; Dehler, M; Godot, J C

    1996-01-01

    For the Compact Linear Collider Test Facility (CTF) at CERN a new rf gun with a laser driven photocathode is under construction. The new rf gun will replace the present 11/2 cell gun and will consist of 21/2 cells accelerating the beam to a momentum of 7.0 MeV/c with an electric field strength of 100 MV/m. The strong space-charge forces at low beam energy caused by the high charge density of the electron bunches are contained by radial and longitudinal rf focusing in the gun. The rf gun under construction has been optimized by MAFIA beam simulations for an injector assembly comprising a second accelerating rf structure and an intermediate solenoid magnet correcting the beam divergence of the 21/2 cell gun. The beam loading of the rf gun, by a train of 48 bunches with 21 nC charge each, causes a strong energy decay accompanied by an increase of the flight time for the bunches with lower energy. These effects can be corrected by slightly shifting the acceleration frequency of the gun. The experimental results...

  15. Bremsstrahlung production with high-intensity laser matter interactions and applications

    NARCIS (Netherlands)

    Galy, J.; Maucec, M.; Hamilton, D. J.; Edwards, R.; Magill, J.

    2007-01-01

    In the last decade an evolution of experimental relativistic laser-plasma physics has led to highly sophisticated lasers, which are now able to generate ultra short pulses and can be focused to intensities in excess of 10(21) W cm(-2), with more than 500 J on target. In the intense electric field of

  16. Bremsstrahlung production with high-intensity laser matter interactions and applications

    NARCIS (Netherlands)

    Galy, J.; Maucec, M.; Hamilton, D. J.; Edwards, R.; Magill, J.

    2007-01-01

    In the last decade an evolution of experimental relativistic laser-plasma physics has led to highly sophisticated lasers, which are now able to generate ultra short pulses and can be focused to intensities in excess of 10(21) W cm(-2), with more than 500 J on target. In the intense electric field of

  17. Scoring system for the selection of high-risk patients in the intensive care unit

    NARCIS (Netherlands)

    Iapichino, G; Mistraletti, G; Corbella, D; Bassi, G; Borotto, E; Miranda, DR; Morabito, A

    2006-01-01

    Objective. Patients admitted to the intensive care unit greatly differ in severity and intensity of care. We devised a system for selecting high-risk patients that reduces bias by excluding low-risk patients and patients with an early death irrespective of the treatment. Design: A posteriori analysi

  18. Is moderate intensity exercise training combined with high intensity interval training more effective at improving cardiorespiratory fitness than moderate intensity exercise training alone?

    Science.gov (United States)

    Roxburgh, Brendon H; Nolan, Paul B; Weatherwax, Ryan M; Dalleck, Lance C

    2014-09-01

    The purpose of this study was to compare the effectiveness of either continuous moderate intensity exercise training (CMIET) alone vs. CMIET combined with a single weekly bout of high intensity interval training (HIIT) on cardiorespiratory fitness. Twenty nine sedentary participants (36.3 ± 6.9 yrs) at moderate risk of cardiovascular disease were recruited for 12 weeks of exercise training on a treadmill and cycle ergometer. Participants were randomised into three groups: CMIET + HIIT (n = 7; 8-12 x 60 sec at 100% VO2max, 150 sec active recovery), CMIET (n = 6; 30 min at 45-60% oxygen consumption reserve (VO2R)) and a sedentary control group (n = 7). Participants in the CMIET + HIIT group performed a single weekly bout of HIIT and four weekly sessions of CMIET, whilst the CMIET group performed five weekly CMIET sessions. Probabilistic magnitude-based inferences were determined to assess the likelihood that the true value of the effect represents substantial change. Relative VO2max increased by 10.1% (benefit possible relative to control) in in the CMIET + HIIT group (32.7 ± 9.2 to 36.0 ± 11.5 mL·kg(-1)·min(-1)) and 3.9% (benefit possible relative to control) in the CMIET group (33.2 ± 4.0 to 34.5 ± 6.1 mL·kg(-1)·min(-1)), whilst there was a 5.7% decrease in the control group (30.0 ± 4.6 to 28.3 ± 6.5 mL·kg(-1)·min(-1)). It was 'unclear' if a clinically significant difference existed between the effect of CMIET + HIIT and CMIET on the change in VO2max. Both exercising groups showed clinically meaningful improvements in VO2max. Nevertheless, it remains 'unclear' whether one type of exercise training regimen elicits a superior improvement in cardiorespiratory fitness relative to its counterpart. Key PointsBoth continuous moderate intensity exercise training (CMIET) alone and CMIET combined with a single weekly bout of high intensity interval training (CMIET + HIIT) elicit 'possibly beneficial' clinically meaningful improvements in cardiorespiratory

  19. Remote Sensing Tertiary Education Meets High Intensity Interval Training

    Science.gov (United States)

    Joyce, K. E.; White, B.

    2015-04-01

    Enduring a traditional lecture is the tertiary education equivalent of a long, slow, jog. There are certainly some educational benefits if the student is able to maintain concentration, but they are just as likely to get caught napping and fall off the back end of the treadmill. Alternatively, a pre-choreographed interactive workshop style class requires students to continually engage with the materials. Appropriately timed breaks or intervals allow students to recover briefly before being increasingly challenged throughout the class. Using an introductory remote sensing class at Charles Darwin University, this case study presents a transition from the traditional stand and deliver style lecture to an active student-led learning experience. The class is taught at undergraduate and postgraduate levels, with both on-campus as well as online distance learning students. Based on the concept that active engagement in learning materials promotes 'stickiness' of subject matter, the remote sensing class was re-designed to encourage an active style of learning. Critically, class content was reviewed to identify the key learning outcomes for the students. This resulted in a necessary sacrifice of topic range for depth of understanding. Graduates of the class reported high levels of enthusiasm for the materials, and the style in which the class was taught. This paper details a number of techniques that were used to engage students in active and problem based learning throughout the semester. It suggests a number of freely available tools that academics in remote sensing and related fields can readily incorporate into their teaching portfolios. Moreover, it shows how simple it can be to provide a far more enjoyable and effective learning experience for students than the one dimensional lecture.

  20. The high intensity solar cell: Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    The design considerations and performance characteristics of the 'high intensity' (HI) solar cell are presented. A high intensity solar system was analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency. It is shown that residential sized systems can be produced at less than $1000/kW peak electric power. Due to their superior high intensity performance characteristics compared to the conventional and VMJ cells, HI cells and light concentrators may be the key to low cost photovoltaic power.

  1. Improved highly accurate localized motion imaging for monitoring high-intensity focused ultrasound therapy

    Science.gov (United States)

    Qu, Xiaolei; Azuma, Takashi; Sugiyama, Ryusuke; Kanazawa, Kengo; Seki, Mika; Sasaki, Akira; Takeuchi, Hideki; Fujiwara, Keisuke; Itani, Kazunori; Tamano, Satoshi; Takagi, Shu; Sakuma, Ichiro; Matsumoto, Yoichiro

    2016-07-01

    Visualizing an area subjected to high-intensity focused ultrasound (HIFU) therapy is necessary for controlling the amount of HIFU exposure. One of the promising monitoring methods is localized motion imaging (LMI), which estimates coagulation length by detecting the change in stiffness. In this study, we improved the accuracy of our previous LMI by dynamic cross-correlation window (DCCW) and maximum vibration amount (MVA) methods. The DCCW method was used to increase the accuracy of estimating vibration amplitude, and the MVA method was employed to increase signal-noise ratio of the decrease ratio at the coagulated area. The qualitative comparison of results indicated that the two proposed methods could suppress the effect of noise. Regarding the results of the quantitative comparison, coagulation length was estimated with higher accuracy by the improved LMI method, and the root-mean-square error (RMSE) was reduced from 2.51 to 1.69 mm.

  2. Meeting standards of high-quality intensive care unit palliative care: clinical performance and predictors.

    Science.gov (United States)

    Penrod, Joan D; Pronovost, Peter J; Livote, Elayne E; Puntillo, Kathleen A; Walker, Amy S; Wallenstein, Sylvan; Mercado, Alice F; Swoboda, Sandra M; Ilaoa, Debra; Thompson, David A; Nelson, Judith E

    2012-04-01

    High-quality care for intensive care unit patients and families includes palliative care. To promote performance improvement, the Agency for Healthcare Research and Quality's National Quality Measures Clearinghouse identified nine evidence-based processes of intensive care unit palliative care (Care and Communication Bundle) that are measured through review of medical record documentation. We conducted this study to examine how frequently the Care and Communication Bundle processes were performed in diverse intensive care units and to understand patient factors that are associated with such performance. Prospective, multisite, observational study of performance of key intensive care unit palliative care processes. A surgical intensive care unit and a medical intensive care unit in two different large academic health centers and a medical-surgical intensive care unit in a medium-sized community hospital. Consecutive adult patients with length of intensive care unit stay ≥5 days. None. Between November 2007 and December 2009, we measured performance by specified day after intensive care unit admission on nine care process measures: Identify medical decision-maker, advance directive and resuscitation preference, distribute family information leaflet, assess and manage pain, offer social work and spiritual support, and conduct interdisciplinary family meeting. Multivariable regression analysis was used to determine predictors of performance of five care processes. We enrolled 518 (94.9%) patients and 336 (83.6%) family members. Performances on pain assessment and management measures were high. In contrast, interdisciplinary family meetings were documented for <20% of patients by intensive care unit day 5. Performance on other measures ranged from 8% to 43%, with substantial variation across and within sites. Chronic comorbidity burden and site were the most consistent predictors of care process performance. Across three intensive care units in this study, performance

  3. Inverse bremsstrahlung absorption with nonlinear effects of high laser intensity and non-Maxwellian distribution.

    Science.gov (United States)

    Weng, Su-Ming; Sheng, Zheng-Ming; Zhang, Jie

    2009-11-01

    Inverse bremsstrahlung (IB) absorption and evolution of the electron distribution function (EDF) in a wide laser intensity range (10;{12}-10;{17} W/cm;{2}) have been studied systematically by a two velocity-dimension Fokker-Planck code. It is found that Langdon's IB operator overestimates the absorption rate at high laser intensity, consequently with an overdistorted non-Maxwellian EDF. According to the small anisotropy of EDF in the oscillation frame, we introduce an IB operator which is similar to Langdon's but without the low laser intensity limit. This operator is appropriate for self-consistently tackling the nonlinear effects of high laser intensity as well as non-Maxwellian EDF. Particularly, our operator is capable of treating IB absorption properly in the indirect and direct-drive inertial confinement fusion schemes with the National Ignition Facility and Laser MegaJoule laser parameters at focused laser intensity beyond 10;{15} W/cm;{2} .

  4. Estimate of the intensities of the radioactive nuclides produced at the super-FRS at the future GSI facility

    Energy Technology Data Exchange (ETDEWEB)

    Ricciardi, M.V.

    2004-11-01

    The principal goal of the new facility is the construction of a worldwide unique and technically innovative accelerator system that will provide an extensive range of particle beams. Proton and antiproton beams will be available and ion beams of all chemical elements up to uranium will be produced with world-record intensities. The main employ of the high-intensity ion beams is the production of energetic beams of short-lived (radioactive) nuclei, in the following referred to as exotic or Rare Isotope Beams (RIBs). RIBs are produced in nuclear reactions experienced by the primary beams of stable particles. We report on the study of the production of radioactive nuclides and of their propagation through the Super-FRS. The study was performed by means of a nuclear-reaction Monte-Carlo code, ABRABLA, opportunely implemented for the above-described purpose. This work offers an overview of the radioactivity production in the Super-FRS area; the latter is the required starting knowledge for the design of the shielding structure. (orig.)

  5. High-density operation of the Proto-MPEX High Intensity Plasma Source

    Science.gov (United States)

    Caughman, J. B. O.; Goulding, R. H.; Biewer, T. M.; Bigelow, T. S.; Campbell, I. H.; Caneses, J.; Diem, S. J.; Martin, E. H.; Parish, C. M.; Rapp, J.; Ray, H. B.; Shaw, G. C.; Showers, M. A.; Donovan, D.; Piotrowicz, P. A.; Martin, D. C.

    2016-10-01

    The Prototype Materials Plasma Experiment (Proto-MPEX) is a linear high-intensity RF plasma source that combines a high-density helicon plasma generator with ion and electron heating sections. It is being used to study the physics of heating over-dense plasmas in a linear configuration with the goal of delivering a plasma heat flux of 10 MW/m2 at a target. The helicon plasma is produced by coupling 13.56 MHz RF power at levels of >100 kW. A 30 kW ion cyclotron antenna has recently been installed, and microwaves at 28 GHz ( 150 kW) are coupled to the electrons in the over-dense helicon plasma via Electron Bernstein Waves (EBW). High plasma densities near the target have been produced in D ( 5 x1019/m3) , and electron temperatures range from 3 to >10 eV, depending on the source parameters. IR camera images of the target plate indicate plasma heat depositions >10 MW/m2 for some operating conditions. Details of the experimental results of the operational domain with respect to Te and ne as well as results from initial plasma material interaction tests will be presented. ORNL is managed by UT-Battelle, LLC, for the U.S. DOE under contract DE-AC-05-00OR22725.

  6. High-Intensity Interval Training Versus Moderate-Intensity Continuous Training in the Prevention/Management of Cardiovascular Disease.

    Science.gov (United States)

    Hussain, Syed R; Macaluso, Andrea; Pearson, Stephen J

    Moderate-intensity continuous training (MICT) has long been considered the most effective exercise treatment modality for the prevention and management of cardiovascular disease (CVD), but more recently high-intensity interval training (HIIT) has been viewed as a potential alternative to MICT in accruing such benefits. HIIT was initially found to induce significant improvements in numerous physiological and health-related indices, to a similar if not superior extent to MICT. Since then, many studies have attempted to explore the potential clinical utility of HIIT, relative to MICT, with respect to treating numerous cardiovascular conditions, such as coronary artery disease, heart failure, stroke, and hypertension. Despite this, however, the efficacy of HIIT in reversing the specific symptoms and risk factors of these cardiovascular pathologies is not well understood. HIIT is often perceived as very strenuous, which could render it unsafe for those at risk of or afflicted with CVD, but these issues are also yet to be reviewed. Furthermore, the optimal HIIT protocol for each of the CVD cohorts has not been established. Thus, the purpose of this review article is to (1) evaluate the efficacy of HIIT relative to MICT in the prevention and management of cardiovascular conditions, and (2) explore any potential safety issues surrounding the suitability and/or tolerability of HIIT for patients with CVD, and the potential optimal prescriptive variables of HIIT for application in the clinical environment.

  7. Intensive lifestyle intervention including high-intensity interval training program improves insulin resistance and fasting plasma glucose in obese patients.

    Science.gov (United States)

    Marquis-Gravel, Guillaume; Hayami, Douglas; Juneau, Martin; Nigam, Anil; Guilbeault, Valérie; Latour, Élise; Gayda, Mathieu

    2015-01-01

    To analyze the effects of a long-term intensive lifestyle intervention including high-intensity interval training (HIIT) and Mediterranean diet (MedD) counseling on glycemic control parameters, insulin resistance and β-cell function in obese subjects. The glycemic control parameters (fasting plasma glucose, glycated hemoglobin), insulin resistance, and β-cell function of 72 obese subjects (54 women; mean age = 53 ± 9 years) were assessed at baseline and upon completion of a 9-month intensive lifestyle intervention program conducted at the cardiovascular prevention and rehabilitation center of the Montreal Heart Institute, from 2009 to 2012. The program included 2-3 weekly supervised exercise training sessions (HIIT and resistance exercise), combined to MedD counseling. Fasting plasma glucose (FPG) (mmol/L) (before: 5.5 ± 0.9; after: 5.2 ± 0.6; P fasting insulin (pmol/L) (before: 98 ± 57; after: 82 ± 43; P = 0.003), and insulin resistance, as assessed by the HOMA-IR score (before: 3.6 ± 2.5; after: 2.8 ± 1.6; P = 0.0008) significantly improved, but not HbA1c (%) (before: 5.72 ± 0.55; after: 5.69 ± 0.39; P = 0.448), nor β-cell function (HOMA-β, %) (before: 149 ± 78; after: 144 ± 75; P = 0.58). Following a 9-month intensive lifestyle intervention combining HIIT and MedD counseling, obese subjects experienced significant improvements of FPG and insulin resistance. This is the first study to expose the effects of a long-term program combining HIIT and MedD on glycemic control parameters among obese subjects.

  8. Endurance capacity and neuromuscular fatigue following high- vs moderate-intensity endurance training: A randomized trial.

    Science.gov (United States)

    O'Leary, T J; Collett, J; Howells, K; Morris, M G

    2017-02-16

    High-intensity exercise induces significant central and peripheral fatigue; however, the effect of endurance training on these mechanisms of fatigue is poorly understood. We compared the effect of cycling endurance training of disparate intensities on high-intensity exercise endurance capacity and the associated limiting central and peripheral fatigue mechanisms. Twenty adults were randomly assigned to 6 weeks of either high-intensity interval training (HIIT, 6-8×5 minutes at halfway between lactate threshold and maximal oxygen uptake [50%Δ]) or volume-matched moderate-intensity continuous training (CONT, ~60-80 minutes at 90% lactate threshold). Two time to exhaustion (TTE) trials at 50%Δ were completed pre- and post-training to assess endurance capacity; the two post-training trials were completed at the pretraining 50%Δ (same absolute intensity) and the "new" post-training 50%Δ (same relative intensity). Pre- and post-exercise responses to femoral nerve and motor cortex stimulation were examined to determine peripheral and central fatigue, respectively. HIIT resulted in greater increases in TTE at the same absolute and relative intensities as pre-training (148% and 43%, respectively) compared with CONT (38% and -4%, respectively) (P≤.019). Compared with pre-training, HIIT increased the level of potentiated quadriceps twitch reduction (-34% vs -43%, respectively, P=.023) and attenuated the level of voluntary activation reduction (-7% vs -3%, respectively, P=.047) following the TTE trial at the same relative intensity. There were no other training effects on neuromuscular fatigue development. This suggests that central fatigue resistance contributes to enhanced high-intensity exercise endurance capacity after HIIT by allowing greater performance to be extruded from the muscle. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. High-intensity focused ultrasound treatment of abnormal vaginal bleeding secondary to uterine myoma.

    Science.gov (United States)

    Lim, Jung Hyun; Chung, Dong Jin; Lim, Young Tec; Cho, Sae Hyun; Lee, Jae Mun; Hahn, Seong-Tae

    2011-03-01

    We describe the use of high-intensity focused ultrasound for acute vaginal bleeding secondary to uterine myoma in 2 young female patients. Both patients had episodes of abnormal vaginal bleeding with severe dysmenorrhea that was not efficiently controlled by medical treatment. After high-intensity focused ultrasound ablation, both vaginal bleeding control and symptom relief were achieved without postinterventional complications. The patients remained free of symptoms during 2 months of follow-up and regained normal menstruation after high-intensity focused ultrasound therapy. High-intensity focused ultrasound treatment is one of the least invasive options for dysfunctional vaginal bleeding and may be an effective and safe alternative to other procedures in women of reproductive age with abnormal vaginal bleeding secondary to uterine myoma.

  10. High speed traveling wave electrooptic intensity modulator with a doped PIN semiconductor junction

    Energy Technology Data Exchange (ETDEWEB)

    Vawter, G.A.; Hietala, V.M.; Wendt, J.R.; Fuchs, B.A.; Hafich, M.; Housel, M.; Armendariz, M.; Sullivan, C.T.

    1996-02-01

    A high-electrooptic-efficiency Mach-Zehnder intensity modulator is demonstrated with a bandwidth exceeding 40 GHZ. The 1 mm-long modulator has a switching voltage comparable to undoped semiconductor designs of much greater length.

  11. Effect of low-intensity extremely high frequency radiation on reproductive function in wistar rats.

    Science.gov (United States)

    Subbotina, T I; Tereshkina, O V; Khadartsev, A A; Yashin, A A

    2006-08-01

    The exposure to low-intensity extremely high frequency electromagnetic radiation during spermatogenesis was accompanied by pathological changes, which resulted in degeneration and polymorphism of spermatozoa. The number of newborn rats increased in the progeny of irradiated animals.

  12. Enhancement of High-Intensity Focused Ultrasound Heating by Short-Pulse Generated Cavitation

    Directory of Open Access Journals (Sweden)

    Shin Yoshizawa

    2017-03-01

    Full Text Available A target tissue can be thermally coagulated in high-intensity focused ultrasound (HIFU treatment noninvasively. HIFU thermal treatments have been clinically applied to various solid tumors. One of the problems in HIFU treatments is a long treatment time. Acoustically driven microbubbles can accelerate the ultrasonic heating, resulting in the significant reduction of the treatment time. In this paper, a method named “trigger HIFU exposure” which employs cavitation microbubbles is introduced and its results are reviewed. A trigger HIFU sequence consists of high-intensity short pulses followed by moderate-intensity long bursts. Cavitation bubbles induced in a multiple focal regions by rapidly scanning the focus of high-intensity pulses enhanced the temperature increase significantly and produced a large coagulation region with high efficiency.

  13. High-Intensity Intermittent Exercise: Effect on Young People's Cardiometabolic Health and Cognition.

    Science.gov (United States)

    Cooper, Simon B; Dring, Karah J; Nevill, Mary E

    2016-01-01

    With only a quarter of young people currently meeting physical activity guidelines, two key areas of concern are the effects of exercise on cardiometabolic health and cognition. Despite the fact that physical activity in young people is typically high intensity and intermittent in nature, much of the literature examines traditional endurance-type exercise. This review provides an update on the effects of high-intensity intermittent exercise on young people's cardiometabolic health and cognition. High-intensity intermittent exercise has acute beneficial effects on endothelial function and postprandial lipemia and chronic positive effects on weight management. In addition, there is emerging evidence regarding chronic benefits on the blood lipid profile, blood pressure, and proinflammatory and anti-inflammatory cytokines. Furthermore, emerging evidence suggests beneficial acute and chronic effects of high-intensity intermittent exercise on cognition. However, further research is required in both cardiometabolic health and cognition, particularly regarding the impact of school-based interventions in adolescents.

  14. Influence of mature men way of life on highly intensive physical activity

    Directory of Open Access Journals (Sweden)

    O.B. Pryshva

    2017-04-01

    Full Text Available Highly intensive physical activity is the most effective for men’s health protection. In modern life conditions its level is insufficient. It requires organism’s appropriate physical activity, which is determined by way of life. Especially important it is before trainings. Purpose: to study special aspects of different intensity’s physical activity; of eating special food and sleeping regime of mature men before their highly intensive physical trainings. Material: in experiment men (n=26, age - 35-53years, who practice healthy life style and independent physical activity of high intensity, participated. We used bio-register Basis B1. Every day we registered: Peak - physical activity of different intensity; duration and quality of sleep; relative weight of consumed food. Besides, we calculated body mass index and physical condition. The study was conducted during 30 days in winter period. The following results were compared: indicators before not planned physical activity and average-monthly indicators. Results: Before arbitrary physical functioning we found in men: confident weakening of average intensity (by 9-11% and low intensity (by 10% physical activity; confident increase of consumed food’s relative weight (by 6.82%, vegetarian food (by 10.64% and raw food (by 7.61%; confident reduction of animal origin food (by 8.7%. No changes were found in duration and quality of sleep before highly intensive physical functioning. Conclusions: specific features of mature men’s way of life before their not planned highly intensive physical functioning are as follows: reduction of general physical activity; increase of consumed food. These factors facilitate energy accumulation in organism for its realization in highly intensive physical functioning the next day.

  15. Application of sound intensity and partial coherence to identify interior noise sources on the high speed train

    Science.gov (United States)

    Fan, Rongping; Su, Zhongqing; Meng, Guang; He, Caichun

    2014-06-01

    In order to provide a quieter riding environment for passengers, sound quality refinement of rail vehicle is a hot issue. Identification of interior noise sources is the prerequisite condition to reduce the interior noise on high speed train. By considering contribution of noise sources such as rolling noise, mechanical equipment noise, structure-borne noise radiated by car body vibration to the interior noise, the synthesized measurement of sound intensity, sound pressure levels and vibration have been carried out in four different carriages on high speed train. The sound intensity and partial coherence methods have been used to identify the most significant interior noise sources. The statistical analysis results of sound intensity near window and floor on four carriages indicate that sound intensity near floor is higher than that near window at three traveling speeds. Ordinary and partial coherent analysis of vibro-acoustical signals show that the major internal noise source is structural-borne sound radiated by floor vibration. These findings can be utilized to facilitate the reduction of interior noise in the future.

  16. Design and implementation of capacitive micromachined ultrasonic transducers for high intensity focused ultrasound

    OpenAIRE

    Yamaner, Yalçın Feysel; Yamaner, Yalcin Feysel

    2011-01-01

    High intensity focused ultrasound (HIFU) is a medical procedure for noninvasive treatment of cancers. High intensity focused ultrasound is used to heat and destroy the diseased tissue. Piezoelectricity has been the core mechanism for generation of ultrasound waves in the treatment. Focusing can be done by using spherically curved transducers or using a lens or electronically steering sound waves by using phased arrays. Current research in HIFU technology targets the development of MR-guided m...

  17. Design concept of radiation control system for the high intensity proton accelerator facility

    CERN Document Server

    Miyamoto, Y; Harada, Y; Ikeno, K

    2002-01-01

    Description is given for the characteristic radiation environment for the High Intensity Proton Accelerator Facility and the design concept of the radiation control system of it. The facility is a large scale accelerator complex consisting of high energy proton accelerators carrying the highest beam intensity in the world and the related experimental facilities and therefore provides various issues relevant to the radiation environment. The present report describes the specifications for the radiation control system for the facility, determined in consideration of these characteristics.

  18. No Effect of Exercise Intensity on Appetite in Highly-Trained Endurance Women

    OpenAIRE

    Howe, Stephanie M; Taryn M. Hand; D. Enette Larson-Meyer; Kathleen J. Austin; Alexander, Brenda M.; Melinda M. Manore

    2016-01-01

    In endurance-trained men, an acute bout of exercise is shown to suppress post-exercise appetite, yet limited research has examined this response in women. The purpose of this study was to investigate the effect of exercise intensity on appetite and gut hormone responses in endurance-trained women. Highly-trained women (n = 15, 18–40 years, 58.4 ± 6.4 kg, VO2MAX = 55.2 ± 4.3 mL/kg/min) completed isocaloric bouts (500 kcals or 2093 kJ) of moderate-intensity (MIE, 60% VO2MAX) and high-intensity ...

  19. High-intensity tasks with external load in military applications: a review.

    Science.gov (United States)

    O'Neal, Eric K; Hornsby, Jared H; Kelleran, Kyle J

    2014-09-01

    This article provides a synopsis of the limited investigations examining the impact of external load (EL) on performance of high-intensity tasks under load (HITL), EL training intervention effects on HITL performance, and injuries from EL training. Repetitive lifting tasks and initiation of locomotion, such as rapidly moving from a prone position to sprinting appear to be more hindered by EL than maximal sprinting velocity and may explain why training with EL does not improve obstacle course or prolonged (200-300 yard shuttle) drills. EL training appears to offer very little if any benefit for HITL in lesser trained populations. This contrast results of multiple studies incorporating ≥ 3 weeks of prolonged hypergravity interventions (wearing EL during daily activities) in elite anaerobic athletes, indicating EL training stimulus is likely only beneficial to well-trained soldiers. Women and lesser trained individuals appear to be more susceptible to increased injury with EL training. A significant limitation concerning current HITL knowledge is the lack of studies incorporating trained soldiers. Future investigations concerning the effects of HITL on marksmanship, repetitive lifting biomechanics, efficacy of hypergravity training for military personnel, and kinematics of sprinting from tactical positions with various EL displacements and technique training are warranted.

  20. High-intensity Fitness Training Among a National Sample of Male Career Firefighters

    Directory of Open Access Journals (Sweden)

    Sara A. Jahnke

    2015-03-01

    Full Text Available Obesity and fitness have been identified as key health concerns among USA firefighters yet little is known about the current habits related to exercise and diet. In particular, high-intensity training (HIT has gained increasing popularity among this population but limited quantitative data are available about how often it is used and the relationship between HIT and other outcomes. Using survey methodology, the current study evaluated self-reported HIT and diet practice among 625 male firefighters. Almost one-third (32.3% of participants reported engaging in HIT. Body composition, as measured by waist circumference and percentage body fat, was significantly related to HIT training, with HIT participants being approximately half as likely to be classified as obese using body fat [odds ratio (OR = 0.52, 95% confidence interval (CI = 0.34–0.78] or waist circumference (OR = 0.61, 95% CI = 0.37–0.98. Those who engaged in HIT were more than twice as likely as those who did not (OR = 2.24, 95% CI = 1.42–3.55 to meet fitness recommendations. Findings highlight directions for future prevention and intervention efforts.

  1. Associations of Low- and High-Intensity Light Activity with Cardiometabolic Biomarkers.

    Science.gov (United States)

    Howard, Bethany; Winkler, Elisabeth A H; Sethi, Parneet; Carson, Valerie; Ridgers, Nicola D; Salmon, J O; Healy, Genevieve N; Owen, Neville; Dunstan, David W

    2015-10-01

    Light-intensity physical activity (LIPA) accounts for much of adults' waking hours (≈40%) and substantially contributes to overall daily energy expenditure. Encompassing activity behaviors of low intensity (standing with little movement) to those of higher intensity (slow walking), LIPA is ubiquitous, yet little is known about how associations with health may vary depending on its intensity. We examined the associations of objectively assessed LIPA (categorized as either low LIPA [LLPA] or high LIPA [HLPA]) and moderate- to vigorous-intensity activity with cardiometabolic risk biomarkers. Cardiometabolic biomarkers were measured in 4614 US adults (47 ± 17 yr) who participated in the 2003-2004 and 2005-2006 National Health and Nutrition Examination Survey cycles. Multiple linear regression analyses examined the associations of three accelerometer-derived physical activity (SD increment per day) intensity categories (LLPA, 100-761 counts per minute; HLPA, 762-1951 counts per minute; moderate-intensity physical activity [MPA], 1952-5724 counts per minute; vigorous-intensity physical activity [VPA], ≥5725 counts per minute) with cardiometabolic biomarkers, adjusting for potential sociodemographic, behavioral, and medical confounders. All intensities of physical activity were beneficially associated with waist circumference, C-reactive protein, triglycerides, fasting insulin, β-cell function, and insulin sensitivity (P activity intensities showed significant associations with systolic blood pressure (LLPA), body mass index, HDL cholesterol, fasting glucose, and 2-h plasma glucose (HLPA, MPA, and VPA). Generally, effect size increased with intensity of physical activity. Overall, further adjustment for waist circumference attenuated associations with MPA and VPA to a greater extent than associations with LLPA and HLPA. The cross-sectional findings provide novel evidence for the potential benefits of increasing both LLPA and HLPA. They further reinforce the

  2. Generation of future high-resolution rainfall time series with a disaggregation model

    Science.gov (United States)

    Müller, Hannes; Haberlandt, Uwe

    2017-04-01

    High-resolution rainfall data are needed in many fields of hydrology and water resources management. For analyzes of future rainfall condition climate scenarios exist with hourly values of rainfall. However, the direct usage of these data is associated with uncertainties which can be indicated by comparisons of observations and C20 control runs. An alternative is the derivation of changes of rainfall behavior over the time from climate simulations. Conclusions about future rainfall conditions can be drawn by adding these changes to observed time series. A multiplicative cascade model is used in this investigation for the disaggregation of daily rainfall amounts to hourly values. Model parameters can be estimated by REMO rainfall time series (UBA-, BfG- and ENS-realization), based on ECHAM5. Parameter estimation is carried out for C20 period as well as near term and long term future (2021-2050 and 2071-2100). Change factors for both future periods are derived by parameter comparisons and added to the parameters estimated from observed time series. This enables the generation of hourly rainfall time series from observed daily values with respect to future changes. The investigation is carried out for rain gauges in Lower Saxony. Generated Time series are analyzed regarding statistical characteristics, e.g. extreme values, event-based (wet spell duration and amounts, dry spell duration, …) and continuum characteristics (average intensity, fraction of dry intervals,…). The generation of the time series is validated by comparing the changes in the statistical characteristics from the REMO data and from the disaggregated data.

  3. The CMS High Level Trigger System: Experience and Future Development

    CERN Document Server

    Bauer, Gerry; Bowen, Matthew; Branson, James G; Bukowiec, Sebastian; Cittolin, Sergio; Coarasa, J A; Deldicque, Christian; Dobson, Marc; Dupont, Aymeric; Erhan, Samim; Flossdorf, Alexander; Gigi, Dominique; Glege, Frank; Gomez-Reino, R; Hartl, Christian; Hegeman, Jeroen; Holzner, André; Y L Hwong; Masetti, Lorenzo; Meijers, Frans; Meschi, Emilio; Mommsen, R K; O'Dell, Vivian; Orsini, Luciano; Paus, Christoph; Petrucci, Andrea; Pieri, Marco; Polese, Giovanni; Racz, Attila; Raginel, Olivier; Sakulin, Hannes; Sani, Matteo; Schwick, Christoph; Shpakov, Dennis; Simon, M; Spataru, A C; Sumorok, Konstanty

    2012-01-01

    The CMS experiment at the LHC features a two-level trigger system. Events accepted by the first level trigger, at a maximum rate of 100 kHz, are read out by the Data Acquisition system (DAQ), and subsequently assembled in memory in a farm of computers running a software high-level trigger (HLT), which selects interesting events for offline storage and analysis at a rate of order few hundred Hz. The HLT algorithms consist of sequences of offline-style reconstruction and filtering modules, executed on a farm of 0(10000) CPU cores built from commodity hardware. Experience from the operation of the HLT system in the collider run 2010/2011 is reported. The current architecture of the CMS HLT, its integration with the CMS reconstruction framework and the CMS DAQ, are discussed in the light of future development. The possible short- and medium-term evolution of the HLT software infrastructure to support extensions of the HLT computing power, and to address remaining performance and maintenance issues, are discussed.

  4. High-intensity exercise attenuates postprandial lipaemia and markers of oxidative stress.

    Science.gov (United States)

    Gabriel, Brendan; Ratkevicius, Aivaras; Gray, Patrick; Frenneaux, Michael P; Gray, Stuart R

    2012-09-01

    Regular exercise can reduce the risk of CVD (cardiovascular disease). Although moderate-intensity exercise can attenuate postprandial TAG (triacylglycerol), high-intensity intermittent exercise might be a more effective method to improve health. We compared the effects of high-intensity intermittent exercise and 30 min of brisk walking on postprandial TAG, soluble adhesion molecules and markers of oxidative stress. Nine men each completed three 2-day trials. On day 1, subjects rested (control), walked briskly for 30 min (walking) or performed 5×30 s maximal sprints (high-intensity). On day 2, subjects consumed a high-fat meal for breakfast and 3 h later for lunch. Blood samples were taken at various times and analysed for TAG, glucose, insulin, ICAM-1 (intracellular adhesion molecule-1), VCAM-1 (vascular adhesion molecule-1), TBARS (thiobarbituric acid- reactive substances), protein carbonyls and β-hydroxybutyrate. On day 2 of the high-intensity trial, there was a lower (Phigh-intensity trial (14.13±2.83 mmol/l per 7 h) compared with control (17.18±3.92 mmol/l per 7 h), walking showed no difference (16.33±3.51 mmol/l per 7 h). On day 2 of the high-intensity trial plasma TBARS and protein carbonyls were also reduced (Phigh-intensity intermittent exercise attenuates postprandial TAG and markers of oxidative stress after the consumption of a high-fat meal.

  5. High Intensity Physical Exercise and Pain in the Neck and Upper Limb among Slaughterhouse Workers: Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Emil Sundstrup

    2014-01-01

    Full Text Available Slaughterhouse work involves a high degree of repetitive and forceful upper limb movements and thus implies an elevated risk of work-related musculoskeletal disorders. High intensity strength training effectively rehabilitates musculoskeletal disorders among sedentary employees, but less is known about the effect among workers with repetitive and forceful work demands. Before performing randomized controlled trials it may be beneficial to assess the cross-sectional connection between exercise and musculoskeletal pain. We investigated the association between high intensity physical exercise and pain among 595 slaughterhouse workers in Denmark, Europe. Using logistic regression analyses, odds ratios for pain and work disability as a function of physical exercise, gender, age, BMI, smoking, and job position were estimated. The prevalence of pain in the neck, shoulder, elbow, and hand/wrist was 48%, 60%, 40%, and 52%, respectively. The odds for experiencing neck pain were significantly lower among slaughterhouse workers performing physical exercise (OR = 0.70, CI: 0.49–0.997, whereas the odds for pain in the shoulders, elbow, or hand/wrist were not associated with exercise. The present study can be used as general reference of pain in the neck and upper extremity among slaughterhouse workers. Future studies should investigate the effect of high intensity physical exercise on neck and upper limb pain in slaughterhouse workers.

  6. Design study of a radio-frequency quadrupole for high-intensity beams

    Science.gov (United States)

    Bahng, Jungbae; Kim, Eun-San; Choi, Bong-Hyuk

    2017-07-01

    The Rare isotope Accelerator Of Newness (RAON) heavy-ion accelerator has been designed for the Rare Isotope Science Project (RISP) in Korea. The RAON will produce heavy-ion beams from 660-MeV-proton to 200-MeV/u-uranium with continuous wave (CW) power of 400 kW to support research in various scientific fields. Its system consists of an ECR ion source, LEBTs with 10 keV/u, CW RFQ accelerator with 81.25 MHz and 500 keV/u, a MEBT system, and a SC linac. In detail, the driver linac system consists of a Quarter Wave Resonator (QWR) section with 81.25 MHz and a Half Wave Resonator (HWR) section with 162.5 MHz, Linac-1, and a Spoke Cavity section with 325 MHz, Linac-2. These linacs have been designed to optimize the beam parameters to meet the required design goals. At the same time, a light-heavy ion accelerator with high-intensity beam, such as proton, deuteron, and helium beams, is required for experiments. In this paper, we present the design study of the high intensity RFQ for a deuteron beam with energies from 30 keV/u to 1.5 MeV/u and currents in the mA range. This system is composed of an Penning Ionization Gauge ion source, short LEBT with a RF deflector, and shared SC Linac. In order to increase acceleration efficiency in a short length with low cost, the 2nd harmonic of 162.5 MHz is applied as the operation frequency in the D+ RFQ design. The D+ RFQ is designed with 4.97 m, 1.52 bravery factor. Since it operates with 2nd harmonic frequency, the beam should be 50% of the duty factor while the cavity should be operated in CW mode, to protect the downstream linac system. We focus on avoiding emittance growth by the space-charge effect and optimizing the RFQ to achieve a high transmission and low emittance growth. Both the RFQ beam dynamics study and RFQ cavity design study for two and three dimensions will be discussed. Supported by Korea University Future Research Grant

  7. EFFECT OF HIGH INTENSITY INTERVAL TRAINING ON ENDOTHELIAL FUNCTION IN POSTMENOPAUSAL HYPERTENSIVE PATIENTS RANDOMIZED CONTROLLED TRIAL

    Directory of Open Access Journals (Sweden)

    Mona Mohamed Taha

    2016-02-01

    Full Text Available Background: Postmenopausal hypertension is the most common risk factor of cardiovascular morbidity and mortality. As the exercises training conveys benefits of the setting of secondary prevention of hypertension. High intensity interval training (HIIT emerged as a new form of physical training and presents as therapeutic alternative to patients and health care professionals. This study aimed to investigate the effect of high intensity interval training on endothelial function in postmenopausal hypertension. Methods: Forty six mildly hypertensive postmenopausal women, their ages ranged from (45-55 years old, were randomly allocated to two groups: HIIT group (group-I; n=23 performed a high intensity interval training 3 times a week for 10 weeks at an intensity of (80-85% HR max for 40 minutes and control group (group-II; n=23 remains sedentary during this period. Serum nitric oxide (NO, vascular endothelial growth factor levels (VEGF and blood pressures were measured before and after intervention. Results: A significant reduction in both systolic and diastolic blood pressure values by 9.5% and 7 % respectively, was seen after high intensity interval training which was accompanied by increase in NO and VEGF levels by 43.3% and 15.2 % respectively, while no significant change observed in the control group. Conclusion: High intensity interval training had obvious benefits in improving plasma No, VEGF concentrations and controlling hypertension in postmenopausal women.

  8. Study in Parkinson Disease of Exercise (SPARX): Translating high-intensity exercise from animals to humans

    Science.gov (United States)

    Moore, Charity G.; Schenkman, Margaret; Kohrt, Wendy M.; Delitto, Anthony; Hall, Deborah A.; Corcos, Daniel

    2013-01-01

    A burgeoning literature suggests that exercise has a therapeutic benefit in persons with Parkinson disease (PD) and in animal models of PD, especially when animals exercise at high intensity. If exercise is to be prescribed as “first-line” or “add-on” therapy in patients with PD, we must demonstrate its efficacy and dose-response effects through testing phases similar to those used in the testing of pharmacologic agents. The SPARX Trial is a multicenter, randomized, controlled, single-blinded, Phase II study that we designed to test the feasibility of using high-intensity exercise to modify symptoms of PD and to simultaneously test the nonfutility of achieving a prespecified change in patients’ motor scores on the Unified Parkinson Disease Rating Scale (UPDRS). The trial began in May 2102 and is in the process of screening, enrolling, and randomly assigning 126 patients with early-stage PD to 1 of 3 groups: usual care (wait-listed controls), moderate-intensity exercise (4 days/week at 60%–65% maximal heart rate [HRmax]), or high-intensity exercise (4 days/week at 80%–85% HRmax). At 6-month follow-up, the trial is randomly reassigning usual care participants to a moderate-intensity or high-intensity exercise group for the remaining 6 months. The goals of the Phase II trial are to determine if participants can exercise at moderate and high intensities; to determine if either exercise yields benefits consistent with meaningful clinical change (nonfutility); and to document safety and attrition. The advantage of using a non-futility approach allows us to efficiently determine if moderate- or high-intensity exercise warrants further large-scale investigation in PD. PMID:23770108

  9. High-intensity erotic visual stimuli de-activate the primary visual cortex in women.

    Science.gov (United States)

    Huynh, Hieu K; Beers, Caroline; Willemsen, Antoon; Lont, Erna; Laan, Ellen; Dierckx, Rudi; Jansen, Monique; Sand, Michael; Weijmar Schultz, Willibrord; Holstege, Gert

    2012-06-01

    The primary visual cortex, Brodmann's area (BA 17), plays a vital role in basic survival mechanisms in humans. In most neuro-imaging studies in which the volunteers have to watch pictures or movies, the primary visual cortex is similarly activated independent of the content of the pictures or movies. However, in case the volunteers perform demanding non-visual tasks, the primary visual cortex becomes de-activated, although the amount of incoming visual sensory information is the same. Do low- and high-intensity erotic movies, compared to neutral movies, produce similar de-activation of the primary visual cortex? Brain activation/de-activation was studied by Positron Emission Tomography scanning of the brains of 12 healthy heterosexual premenopausal women, aged 18-47, who watched neutral, low- and high-intensity erotic film segments. We measured differences in regional cerebral blood flow (rCBF) in the primary visual cortex during watching neutral, low-intensity erotic, and high-intensity erotic film segments. Watching high-intensity erotic, but not low-intensity erotic movies, compared to neutral movies resulted in strong de-activation of the primary (BA 17) and adjoining parts of the secondary visual cortex. The strong de-activation during watching high-intensity erotic film might represent compensation for the increased blood supply in the brain regions involved in sexual arousal, also because high-intensity erotic movies do not require precise scanning of the visual field, because the impact is clear to the observer. © 2012 International Society for Sexual Medicine.

  10. High intensity polarization entangled source with a 2D nonlinear photonic crystal

    DEFF Research Database (Denmark)

    Wang, Qin

    2009-01-01

    We gave a proposal on how to use a piece of two-dimension (2D) nonlinear photonic crystal to generate a polarization entangled source. It provides not only has a high stability, but also a high entangled quality and a high intensity. Moreover, our scheme involves only practical experimental...

  11. Two weeks of moderate intensity continuous training, but not high intensity interval training increases insulin-stimulated intestinal glucose uptake.

    Science.gov (United States)

    Motiani, Kumail Kumar; Savolainen, Anna M; Eskelinen, Jari-Joonas; Toivanen, Jussi; Ishizu, Tamiko; Yli-Karjanmaa, Minna; Virtanen, Kirsi A; Parkkola, Riitta; Kapanen, Jukka; Gronroos, Tove J; Haaparanta-Solin, Merja; Solin, Olof; Savisto, Nina; Ahotupa, Markku; Löyttyniemi, Eliisa; Knuuti, Juhani; Nuutila, Pirjo; Kalliokoski, Kari K; Hannukainen, Jarna C

    2017-02-09

    Similar to muscles, the intestine is also insulin resistant in obese subjects and subjects with impaired glucose tolerance. Exercise training improves muscle insulin sensitivity, but its effects on intestinal metabolism are not known. We studied the effects of high intensity interval training (HIIT) and moderate intensity continuous training (MICT) on intestinal glucose and free fatty acid uptake from circulation in humans. Twenty-eight healthy middle-aged sedentary men were randomized for two weeks of HIIT or MICT. Intestinal insulin-stimulated glucose uptake and fasting free fatty acid uptake from circulation were measured using positron emission tomography and [(18)F]FDG and [(18)F]FTHA. In addition, effects of HIIT and MICT on intestinal Glut2 and CD36 protein expression were studied in rats. Training improved aerobic capacity (p=0.001) and whole-body insulin sensitivity (p=0.04), but not differently between HIIT and MICT. Insulin-stimulated glucose uptake increased only after the MICT in the colon [HIIT=0%; MICT=37%] (p=0.02 for time*training) and tended to increase in the jejunum [HIIT=-4%; MICT=13%] (p=0.08 for time*training). Fasting free fatty acid uptake decreased in the duodenum in both groups [HIIT=-6%; MICT=-48%] (p=0.001 time) and tended to decrease in the colon in the MICT group [HIIT=0%; MICT=-38%] (p=0.08 for time*training). In rats, both training groups had higher Glut2 and CD36 expression compared to control animals. This study shows that already two weeks of MICT enhances insulin-stimulated glucose uptake while both training modes reduce fasting free fatty acid uptake in the intestine in healthy middle-aged men, providing an additional mechanism by which exercise training can improve whole body metabolism.

  12. Metabolic and hormonal responses to isoenergetic high-intensity interval exercise and continuous moderate-intensity exercise.

    Science.gov (United States)

    Peake, Jonathan M; Tan, Sok Joo; Markworth, James F; Broadbent, James A; Skinner, Tina L; Cameron-Smith, David

    2014-10-01

    This study investigated the effects of high-intensity interval training (HIIT) vs. work-matched moderate-intensity continuous exercise (MOD) on metabolism and counterregulatory stress hormones. In a randomized and counterbalanced order, 10 well-trained male cyclists and triathletes completed a HIIT session [81.6 ± 3.7% maximum oxygen consumption (V̇o2 max); 72.0 ± 3.2% peak power output; 792 ± 95 kJ] and a MOD session (66.7 ± 3.5% V̇o2 max; 48.5 ± 3.1% peak power output; 797 ± 95 kJ). Blood samples were collected before, immediately after, and 1 and 2 h postexercise. Carbohydrate oxidation was higher (P = 0.037; 20%), whereas fat oxidation was lower (P = 0.037; -47%) during HIIT vs. MOD. Immediately after exercise, plasma glucose (P = 0.024; 20%) and lactate (P HIIT vs. MOD, whereas total serum free fatty acid concentration was not significantly different (P = 0.33). Targeted gas chromatography-mass spectromtery metabolomics analysis identified and quantified 49 metabolites in plasma, among which 11 changed after both HIIT and MOD, 13 changed only after HIIT, and 5 changed only after MOD. Notable changes included substantial increases in tricarboxylic acid intermediates and monounsaturated fatty acids after HIIT and marked decreases in amino acids during recovery from both trials. Plasma adrenocorticotrophic hormone (P = 0.019), cortisol (P HIIT. Plasma norepinephrine (P = 0.11) and interleukin-6 (P = 0.20) immediately after exercise were not significantly different between trials. Plasma insulin decreased during recovery from both HIIT and MOD (P HIIT vs. MOD and highlight the value of targeted metabolomic analysis to provide more detailed insights into the metabolic demands of exercise.

  13. High-Intensity Interval Training as an Efficacious Alternative to Moderate-Intensity Continuous Training for Adults with Prediabetes

    Directory of Open Access Journals (Sweden)

    Mary E. Jung

    2015-01-01

    Full Text Available Aims. High-intensity interval training (HIIT leads to improvements in various markers of cardiometabolic health but adherence to HIIT following a supervised laboratory intervention has yet to be tested. We compared self-report and objective measures of physical activity after one month of independent exercise in individuals with prediabetes who were randomized to HIIT (n=15 or traditional moderate-intensity continuous training (MICT, n=17. Method. After completing 10 sessions of supervised training participants were asked to perform HIIT or MICT three times per week for four weeks. Results. Individuals in HIIT (89 ± 11% adhered to their prescribed protocol to a greater extent than individuals in MICT (71 ± 31% as determined by training logs completed over one-month follow-up (P = 0.05, Cohen’s d = 0.75. Minutes spent in vigorous physical activity per week measured by accelerometer were higher in HIIT (24 ± 18 as compared to MICT (11 ± 10 at one-month follow-up (P = 0.049, Cohen’s d = 0.92. Cardiorespiratory fitness and systolic blood pressure assessed at one-month follow-up were equally improved (P’s < 0.05. Conclusions. This study provides preliminary evidence that individuals with prediabetes can adhere to HIIT over the short-term and do so at a level that is greater than MICT.

  14. The effect of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players.

    Science.gov (United States)

    Lyons, Mark; Al-Nakeeb, Yahya; Hankey, Joanne; Nevill, Alan

    2013-01-01

    Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player's achievement motivation characteristics. 13 expert (7 male, 6 female) and 17 non-expert (13 male, 4 female) tennis players participated in the study. Groundstroke accuracy was assessed using the modified Loughborough Tennis Skills Test. Fatigue was induced using the Loughborough Intermittent Tennis Test with moderate (70%) and high-intensities (90%) set as a percentage of peak heart rate (attained during a tennis-specific maximal hitting sprint test). Ratings of perceived exertion were used as an adjunct to the monitoring of heart rate. Achievement goal indicators for each player were assessed using the 2 x 2 Achievement Goals Questionnaire for Sport in an effort to examine if this personality characteristic provides insight into how players perform under moderate and high-intensity fatigue conditions. A series of mixed ANOVA's revealed significant fatigue effects on groundstroke accuracy regardless of expertise. The expert players however, maintained better groundstroke accuracy across all conditions compared to the novice players. Nevertheless, in both groups, performance following high-intensity fatigue deteriorated compared to performance at rest and performance while moderately fatigued. Groundstroke accuracy under moderate levels of fatigue was equivalent to that at rest. Fatigue effects were also similar regardless of gender. No fatigue by expertise, or fatigue by gender interactions were found. Fatigue effects were also equivalent regardless of player's achievement goal indicators. Future research is required to explore the effects of fatigue on performance in tennis

  15. High Pressure Oxygen Generation for Future Exploration Missions Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation is the development of a cathode feed electrolysis cell stack capable of generating 3600 psia oxygen at a relevant scale for future...

  16. Hot electron generation and energy coupling in planar experiments with shock ignition high intensity lasers

    Science.gov (United States)

    Wei, M. S.; Krauland, C.; Alexander, N.; Zhang, S.; Peebles, J.; Beg, F. N.; Theobald, W.; Borwick, E.; Ren, C.; Yan, R.; Haberberger, D.; Betti, R.; Campbell, E. M.

    2016-10-01

    Hot electrons produced in nonlinear laser plasma interactions are critical issues for shock ignition (SI) laser fusion. We conducted planar target experiments to characterize hot electron and energy coupling using the high energy OMEGA EP laser system at SI high intensities. Targets were multilayered foils consisting of an ablator (either plastic or lithium) and a Cu layer to facilitate hot electron detection via fluorescence and bremsstrahlung measurements. The target was first irradiated by multi-kJ, low-intensity UV beams to produce a SI-relevant mm-scale hot ( 1 keV) preformed plasma. The main interaction pulse, either a kJ 1-ns UV pulse with intensity 1.6x1016 Wcm-2 or a kJ 0.1-ns IR pulse with intensity up to 2x1017 Wcm-2was injected at varied timing delays. The high intensity IR beam was found to strongly interact with underdense plasmas breaking into many filaments near the quarter critical density region followed by propagation of those filaments to critical density, producing hot electrons with Thot 70 keV in a well-contained beam. While the high intensity UV beam showed poor energy coupling. Details of the experiments and the complementary PIC modeling results will be presented. Work supported by U.S. DOE under contracts DE-NA0002730 (NLUF) and DE-SC0014666 (HEDLP).

  17. Anthropometric, Sprint, and High-Intensity Running Profiles of English Academy Rugby Union Players by Position.

    Science.gov (United States)

    Darrall-Jones, Joshua D; Jones, Ben; Till, Kevin

    2016-05-01

    The purpose of this study was to evaluate the anthropometric, sprint, and high-intensity running profiles of English academy rugby union players by playing positions, and to investigate the relationships between anthropometric, sprint, and high-intensity running characteristics. Data were collected from 67 academy players after the off-season period and consisted of anthropometric (height, body mass, sum of 8 skinfolds [∑SF]), 40-m linear sprint (5-, 10-, 20-, and 40-m splits), the Yo-Yo intermittent recovery test level 1 (Yo-Yo IRTL-1), and the 30-15 intermittent fitness test (30-15 IFT). Forwards displayed greater stature, body mass, and ∑SF; sprint times and sprint momentum, with lower high-intensity running ability and sprint velocities than backs. Comparisons between age categories demonstrated body mass and sprint momentum to have the largest differences at consecutive age categories for forwards and backs; whereas 20-40-m sprint velocity was discriminate for forwards between under 16s, 18s, and 21s. Relationships between anthropometric, sprint velocity, momentum, and high-intensity running ability demonstrated body mass to negatively impact on sprint velocity (10 m; r = -0.34 to -0.46) and positively affect sprint momentum (e.g., 5 m; r = 0.85-0.93), with large to very large negative relationships with the Yo-Yo IRTL-1 (r = -0.65 to -0.74) and 30-15 IFT (r = -0.59 to -0.79). These findings suggest that there are distinct anthropometric, sprint, and high-intensity running ability differences between and within positions in junior rugby union players. The development of sprint and high-intensity running ability may be impacted by continued increases in body mass as there seems to be a trade-off between momentum, velocity, and the ability to complete high-intensity running.

  18. Effect of moderate- and high-intensity acute exercise on appetite in obese individuals

    DEFF Research Database (Denmark)

    Martins, Catia; Stensvold, Dorthe; Finlayson, Graham

    2015-01-01

    cycling (MICC) or short-duration HIIC (S-HIIC) (125 kcal) and a resting control condition on the appetite hormone responses, subjective feelings of appetite, energy intake (EI), and food reward in overweight/obese individuals. METHODS: This study is a randomized crossover study on 12 overweight/obese......, hunger or fullness ratings, EI, or food reward. CONCLUSIONS: Our findings suggest that, in overweight/obese individuals, isocaloric bouts of moderate- or high-intensity exercise lead to a similar appetite response. This strengthens previous findings in normal-weight individuals that acute exercise, even......PURPOSE: The effect of acute exercise, and exercise intensity, on appetite control in obese individuals requires further study. The aim of this study was to compare the effects of acute isocaloric bouts (250 kcal) of high-intensity intermittent cycling (HIIC) and moderate-intensity continuous...

  19. Whole pelvic intensity-modulated radiotherapy for high-risk prostate cancer: a preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Ji Hyeon; Kim, Yeon Joo; Kim, Young Seok [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); and others

    2013-12-15

    To assess the clinical efficacy and toxicity of whole pelvic intensity-modulated radiotherapy (WP-IMRT) for high-risk prostate cancer. Patients with high-risk prostate cancer treated between 2008 and 2013 were reviewed. The study included patients who had undergone WP-IMRT with image guidance using electronic portal imaging devices and/or cone-beam computed tomography. The endorectal balloon was used in 93% of patients. Patients received either 46 Gy to the whole pelvis plus a boost of up to 76 Gy to the prostate in 2 Gy daily fractions, or 44 Gy to the whole pelvis plus a boost of up to 72.6 Gy to the prostate in 2.2 Gy fractions. The study cohort included 70 patients, of whom 55 (78%) had a Gleason score of 8 to 10 and 50 (71%) had a prostate-specific antigen level > 20 ng/mL. The androgen deprivation therapy was combined in 62 patients. The biochemical failure-free survival rate was 86.7% at 2 years. Acute any grade gastrointestinal (GI) and genitourinary (GU) toxicity rates were 47% and 73%, respectively. The actuarial rate of late grade 2 or worse toxicity at 2 years was 12.9% for GI, and 5.7% for GU with no late grade 4 toxicity. WP-IMRT was well tolerated with no severe acute or late toxicities, resulting in at least similar biochemical control to that of the historic control group with a small field. The long-term efficacy and toxicity will be assessed in the future, and a prospective randomized trial is needed to verify these findings.

  20. Impact of the dipole-moment representation on the intensity of high overtones

    Science.gov (United States)

    Medvedev, Emile S.; Meshkov, Vladimir V.; Stolyarov, Andrey V.; Ushakov, Vladimir G.; Gordon, Iouli E.

    2016-12-01

    Calculating intensities of ro-vibrational transitions is particularly challenging for transitions from a given vibrational state to all upper states up to the dissociation limit because their probabilities decrease exponentially with increasing Δn , the change in the vibrational quantum number. The experimental intensities available for low- Δn values are well reproduced by a variety of models but the models can greatly diverge in predicting the intensities of unobserved high-overtone transitions, the divergence rapidly increasing with the overtone number. In this paper, we investigate the impact of the dipole-moment function (DMF) representation on the high-overtone intensity simulation of the CO molecule. We tested various DMF forms including pointwise representation combined with cubic-spline interpolation, power and trigonometric expansions, and Padé approximants. Numerical calculations were performed with the highly accurate empirical potential-energy function (PEF) of Coxon and Hajigeorgiou (2004) using quadruple-precision arithmetic. Most calculated intensities fall off in the entire range of transitions according to the Normal Intensity Distribution Law (NIDL) (Medvedev, 2012). The slope of the NIDL trend line varies little between different analytical DMFs for a given PEF since the slope is basically associated with the PEF. Based on the NIDL, the limits within which the simulated intensities fall off up to the dissociation limit can be established. We claim that DMFs represented by analytical functions yield best results for all transitions. The pointwise functions (interpolated, in particular, by the conventional cubic splines) result in an unphysical flattening of the intensities at high- Δn transitions, Δn > 7 for CO.

  1. Nutritional strategies to support adaptation to high-intensity interval training in team sports.

    Science.gov (United States)

    Gibala, Martin J

    2013-01-01

    Team sports are characterized by intermittent high-intensity activity patterns. Typically, play consists of short periods of very intense or all-out efforts interspersed with longer periods of low-intensity activity. Fatigue is a complex, multi-factorial process, but intense intermittent exercise performance can potentially be limited by reduced availability of substrates stored in skeletal muscle and/or metabolic by-products associated with fuel breakdown. High-intensity interval training (HIT) has been shown to induce adaptations in skeletal muscle that enhance the capacity for both oxidative and non-oxidative metabolism. Nutrient availability is a potent modulator of many acute physiological responses to exercise, including various molecular signaling pathways that are believed to regulate cellular adaptation to training. Several nutritional strategies have also been reported to acutely alter metabolism and enhance intermittent high-intensity exercise performance. However, relatively little is known regarding the effect of chronic interventions, and whether supplementation over a period of weeks or months augments HIT-induced physiological remodeling and promotes greater performance adaptations. Theoretically, a nutritional intervention could augment HIT adaptation by improving energy metabolism during exercise, which could facilitate greater total work and an enhanced chronic training stimulus, or promoting some aspect of the adaptive response during recovery, which could lead to enhanced physiological adaptations over time.

  2. High signal intensity of the septum pellucidum at MR imaging; Significance in hydrocephalus

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jeong Hee; Kim, Eun Ha; Chung, Chun Phil; Kim, Chang Soo [Maryknoll Hospital, Pusan (Korea, Republic of)

    1994-05-15

    To evaluate the significance of high signal intensity of the septum pellucidum in hydrocephalus on proton density-weighted brain MR images. Authors reviewed the MR images of 418 cases of patients with normal (175 case), hydrocephalic(35 cases), atrophic(58 cases), and other groups(150 cases) retrospectively. We analyzed the signal intensity of the septum pellucidum in the normal group and the incidences of high signal intensities of periventricular area of frontal horn of lateral ventricle(area 1), periventricular area except area 1 (area 2), callososeptal area(area 3), and septum pellucidum(area 4) in the normal and abnormal groups. In the normal group, the septum pellucidum was isointense to the head of caudate nucleus on proton density-weighted image. High signal intensity of the septum pellucidum was seen in 31 cases (22 cases of hydrocephalus, 5 cases of brain atrophy, and 4 cases of others), and showed high specificity(91.4%) for hydrocephalus in spite of low sensitivity(62.9%), as compared with periventricular hyperintensities of other areas. High signal intensity of the septum pellucidum on proton density- weighted image may be caused by transependymal CSF migration in the patients with hydrocephalus, and considered as an additional finding of hydrocephalus in the cases of ventriculomegaly.

  3. Where does HIT fit? An examination of the affective response to high-intensity intervals in comparison to continuous moderate- and continuous vigorous-intensity exercise in the exercise intensity-affect continuum.

    Directory of Open Access Journals (Sweden)

    Mary E Jung

    Full Text Available Affect experienced during an exercise session is purported to predict future exercise behaviour. Compared to continuous moderate-intensity exercise (CMI, the affective response to continuous vigorous-intensity exercise (CVI has consistently been shown to be more aversive. The affective response, and overall tolerability to high-intensity interval training (HIT, is less studied. To date, there has yet to be a comparison between HIT, CVI, and CMI. The purpose of this study was to compare the tolerability and affective responses during HIT to CVI and CMI. This study utilized a repeated measures, randomized, counter-balanced design. Forty-four participants visited the laboratory on four occasions. Baseline fitness testing was conducted to establish peak power output in Watts (W peak. Three subsequent visits involved a single bout of a HIT, corresponding to 1-minute at ∼ 100% W peak and 1-minute at ∼ 20% W peak for 20 minutes, b CMI, corresponding to ∼ 40% W peak for 40 minutes, and c CVI, corresponding to ∼ 80% W peak for 20 minutes. The order of the sessions was randomized. Affective responses were measured before, during and after each session. Task self-efficacy, intentions, enjoyment and preference were measured after sessions. Participants reported greater enjoyment of HIT as compared to CMI and CVI, with over 50% of participants reporting a preference to engage in HIT as opposed to either CMI or CVI. HIT was considered more pleasurable than CVI after exercise, but less pleasurable than CMI at these times. Despite this participants reported being just as confident to engage in HIT as they were CMI, but less confident to engage in CVI. This study highlights the utility of HIT in inactive individuals, and suggests that it may be a viable alternative to traditionally prescribed continuous modalities of exercise for promoting self-efficacy and enjoyment of exercise.

  4. THE EFFECT OF MODERATE AND HIGH-INTENSITY FATIGUE ON GROUNDSTROKE ACCURACY IN EXPERT AND NON-EXPERT TENNIS PLAYERS

    Directory of Open Access Journals (Sweden)

    Mark Lyons

    2013-06-01

    Full Text Available Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player's achievement motivation characteristics. 13 expert (7 male, 6 female and 17 non-expert (13 male, 4 female tennis players participated in the study. Groundstroke accuracy was assessed using the modified Loughborough Tennis Skills Test. Fatigue was induced using the Loughborough Intermittent Tennis Test with moderate (70% and high-intensities (90% set as a percentage of peak heart rate (attained during a tennis-specific maximal hitting sprint test. Ratings of perceived exertion were used as an adjunct to the monitoring of heart rate. Achievement goal indicators for each player were assessed using the 2 x 2 Achievement Goals Questionnaire for Sport in an effort to examine if this personality characteristic provides insight into how players perform under moderate and high-intensity fatigue conditions. A series of mixed ANOVA's revealed significant fatigue effects on groundstroke accuracy regardless of expertise. The expert players however, maintained better groundstroke accuracy across all conditions compared to the novice players. Nevertheless, in both groups, performance following high-intensity fatigue deteriorated compared to performance at rest and performance while moderately fatigued. Groundstroke accuracy under moderate levels of fatigue was equivalent to that at rest. Fatigue effects were also similar regardless of gender. No fatigue by expertise, or fatigue by gender interactions were found. Fatigue effects were also equivalent regardless of player's achievement goal indicators. Future research is required to explore the effects of fatigue on

  5. A feasibility study of high intensity positron sources for the S-band and TESLA linear colliders

    Energy Technology Data Exchange (ETDEWEB)

    Glantz, R.

    1997-10-01

    Future high energy linear colliders require luminosities above 10{sup 33} cm{sup -2}s{sup -1}. Therefore beam intensities have to be provided up to two orders of magnitude higher than achieved at present. It is comparably simple to reach high electron intensities. Positron intensities in this range, however, are difficult to realize with conventional positron sources. A new method of positron production was proposed in 1979 by V.E. Balakin and A.A. Mikhailichenko. The photons, necessary for pair production, are not generated by bremsstrahlung but by high energy electrons passing through an undulator. Based on this principle, a high intensity, unpolarized and polarized positron source for linear colliders was developed by K.Floettmann. In the present work, the requirements derived by K.Floettmann are used to study the feasibility of both the polarized and the unpolarized positron source. For economical reasons it is advantageous to use the beam after the interaction for positron production. In the main part of the present work a beam line is developed which guarantees a stable operation of the unpolarized wiggler-based positron source for the S-Band and TESLA linear collider. The requirements on the electron beam emittances are much higher for the polarized undulator-based source. For TESLA it is shown, that an operation of the polarized source is possible for design interactions. For a stable operation, taking into account perturbations at the interaction point, further investigations are necessary. For the SBLC, an operation of the polarized source is not possible with the present design.

  6. The Effects of High-Intensity versus Low-Intensity Resistance Training on Leg Extensor Power and Recovery of Knee Function after ACL-Reconstruction

    DEFF Research Database (Denmark)

    Bieler, Theresa; Sobol, Nanna Aue; Andersen, Lars L

    2014-01-01

    OBJECTIVE: Persistent weakness is a common problem after anterior cruciate ligament- (ACL-) reconstruction. This study investigated the effects of high-intensity (HRT) versus low-intensity (LRT) resistance training on leg extensor power and recovery of knee function after ACL-reconstruction. METH...

  7. High-Resolution Modeling to Assess Tropical Cyclone Activity in Future Climate Regimes

    Energy Technology Data Exchange (ETDEWEB)

    Lackmann, Gary

    2013-06-10

    Applied research is proposed with the following objectives: (i) to determine the most likely level of tropical cyclone intensity and frequency in future climate regimes, (ii) to provide a quantitative measure of uncertainty in these predictions, and (iii) to improve understanding of the linkage between tropical cyclones and the planetary-scale circulation. Current mesoscale weather forecasting models, such as the Weather Research and Forecasting (WRF) model, are capable of simulating the full intensity of tropical cyclones (TC) with realistic structures. However, in order to accurately represent both the primary and secondary circulations in these systems, model simulations must be configured with sufficient resolution to explicitly represent convection (omitting the convective parameterization scheme). Most previous numerical studies of TC activity at seasonal and longer time scales have not utilized such explicit convection (EC) model runs. Here, we propose to employ the moving nest capability of WRF to optimally represent TC activity on a seasonal scale using a downscaling approach. The statistical results of a suite of these high-resolution TC simulations will yield a realistic representation of TC intensity on a seasonal basis, while at the same time allowing analysis of the feedback that TCs exert on the larger-scale climate system. Experiments will be driven with analyzed lateral boundary conditions for several recent Atlantic seasons, spanning a range of activity levels and TC track patterns. Results of the ensemble of WRF simulations will then be compared to analyzed TC data in order to determine the extent to which this modeling setup can reproduce recent levels of TC activity. Next, the boundary conditions (sea-surface temperature, tropopause height, and thermal/moisture profiles) from the recent seasons will be altered in a manner consistent with various future GCM/RCM scenarios, but that preserves the large-scale shear and incipient disturbance

  8. High-Intensity Intermittent Swimming Improves Cardiovascular Health Status for Women with Mild Hypertension

    Directory of Open Access Journals (Sweden)

    Magni Mohr

    2014-01-01

    Full Text Available To test the hypothesis that high-intensity swim training improves cardiovascular health status in sedentary premenopausal women with mild hypertension, sixty-two women were randomized into high-intensity (n=21; HIT, moderate-intensity (n=21; MOD, and control groups (n=20; CON. HIT performed 6–10 × 30 s all-out swimming interspersed by 2 min recovery and MOD swam continuously for 1 h at moderate intensity for a 15-week period completing in total 44±1 and 43±1 sessions, respectively. In CON, all measured variables were similar before and after the intervention period. Systolic BP decreased (P<0.05 by 6±1 and 4±1 mmHg in HIT and MOD; respectively. Resting heart rate declined (P<0.05 by 5±1 bpm both in HIT and MOD, fat mass decreased (P<0.05 by 1.1±0.2 and 2.2±0.3 kg, respectively, while the blood lipid profile was unaltered. In HIT and MOD, performance improved (P<0.05 for a maximal 10 min swim (13±3% and 22±3%, interval swimming (23±3% and 8±3%, and Yo-Yo IE1 running performance (58±5% and 45±4%. In conclusion, high-intensity intermittent swimming is an effective training strategy to improve cardiovascular health and physical performance in sedentary women with mild hypertension. Adaptations are similar with high- and moderate-intensity training, despite markedly less total time spent and distance covered in the high-intensity group.

  9. High Intensity Interval Training Leads to Greater Improvements in Acute Heart Rate Recovery and Anaerobic Power as High Volume Low Intensity Training

    Directory of Open Access Journals (Sweden)

    Thomas L. Stöggl

    2017-08-01

    Full Text Available The purpose of the current study was to explore if training regimes utilizing diverse training intensity distributions result in different responses on neuromuscular status, anaerobic capacity/power and acute heart rate recovery (HRR in well-trained endurance athletes.Methods: Thirty-six male (n = 33 and female (n = 3 runners, cyclists, triathletes and cross-country skiers [peak oxygen uptake: (VO2peak: 61.9 ± 8.0 mL·kg−1·min−1] were randomly assigned to one of three groups (blocked high intensity interval training HIIT; polarized training POL; high volume low intensity oriented control group CG/HVLIT applying no HIIT. A maximal anaerobic running/cycling test (MART/MACT was performed prior to and following a 9-week training period.Results: Only the HIIT group achieved improvements in peak power/velocity (+6.4%, P < 0.001 and peak lactate (P = 0.001 during the MART/MACT, while, unexpectedly, in none of the groups the performance at the established lactate concentrations (4, 6, 10 mmol·L−1 was changed (P > 0.05. Acute HRR was improved in HIIT (11.2%, P = 0.002 and POL (7.9%, P = 0.023 with no change in the HVLIT oriented control group.Conclusion: Only a training regime that includes a significant amount of HIIT improves the neuromuscular status, anaerobic power and the acute HRR in well-trained endurance athletes. A training regime that followed more a low and moderate intensity oriented model (CG/HVLIT had no effect on any performance or HRR outcomes.

  10. Dynamics of cavitation clouds within a high-intensity focused ultrasonic beam

    NARCIS (Netherlands)

    Lu, Yuan; Katz, Joseph; Prosperetti, Andrea

    2013-01-01

    In this experimental study, we generate a 500 kHz high-intensity focused ultrasonic beam, with pressure amplitude in the focal zone of up to 1.9 MPa, in initially quiescent water. The resulting pressure field and behavior of the cavitation bubbles are measured using high-speed digital in-line hologr

  11. Optimizing Planning and Delivery of High-Precision Robotic Radiotherapy and Intensity-Modulated Proton Therapy

    NARCIS (Netherlands)

    S. van de Water (Steven)

    2015-01-01

    markdownabstract__Abstract__ High-precision robotic radiotherapy and intensity-modulated proton therapy (IMPT) are two relatively new radiotherapy techniques that particularly aim at a highly localized delivery of a curative dose to the tumor, while achieving excellent sparing of the surrounding

  12. A High School Intensive Summer Mandarin Course: Program Model and Learner Outcomes

    Science.gov (United States)

    Xu, Xiaoqiu; Padilla, Amado M.; Silva, Duarte; Masuda, Norman

    2012-01-01

    This article describes a STARTALK intensive summer high school Mandarin language and culture program that was conducted for three summers. Participants across the three years included 40 Mandarin Level II and 53 Mandarin Level III high school students. Quantitative and qualitative data are presented to show the effectiveness of the program.…

  13. Optimizing Planning and Delivery of High-Precision Robotic Radiotherapy and Intensity-Modulated Proton Therapy

    NARCIS (Netherlands)

    S. van de Water (Steven)

    2015-01-01

    markdownabstract__Abstract__ High-precision robotic radiotherapy and intensity-modulated proton therapy (IMPT) are two relatively new radiotherapy techniques that particularly aim at a highly localized delivery of a curative dose to the tumor, while achieving excellent sparing of the surrounding he

  14. Is Moderate Intensity Exercise Training Combined with High Intensity Interval Training More Effective at Improving Cardiorespiratory Fitness than Moderate Intensity Exercise Training Alone?

    Directory of Open Access Journals (Sweden)

    Brendon H. Roxburgh, Paul B. Nolan, Ryan M. Weatherwax, Lance C. Dalleck

    2014-09-01

    Full Text Available The purpose of this study was to compare the effectiveness of either continuous moderate intensity exercise training (CMIET alone vs. CMIET combined with a single weekly bout of high intensity interval training (HIIT on cardiorespiratory fitness. Twenty nine sedentary participants (36.3 ± 6.9 yrs at moderate risk of cardiovascular disease were recruited for 12 weeks of exercise training on a treadmill and cycle ergometer. Participants were randomised into three groups: CMIET + HIIT (n = 7; 8-12 x 60 sec at 100% VO2max, 150 sec active recovery, CMIET (n = 6; 30 min at 45-60% oxygen consumption reserve (VO2R and a sedentary control group (n = 7. Participants in the CMIET + HIIT group performed a single weekly bout of HIIT and four weekly sessions of CMIET, whilst the CMIET group performed five weekly CMIET sessions. Probabilistic magnitude-based inferences were determined to assess the likelihood that the true value of the effect represents substantial change. Relative VO2max increased by 10.1% (benefit possible relative to control in in the CMIET + HIIT group (32.7 ± 9.2 to 36.0 ± 11.5 mL·kg-1·min-1 and 3.9% (benefit possible relative to control in the CMIET group (33.2 ± 4.0 to 34.5 ± 6.1 mL·kg-1·min-1, whilst there was a 5.7% decrease in the control group (30.0 ± 4.6 to 28.3 ± 6.5 mL·kg-1·min-1. It was ‘unclear’ if a clinically significant difference existed between the effect of CMIET + HIIT and CMIET on the change in VO2max. Both exercising groups showed clinically meaningful improvements in VO2max. Nevertheless, it remains ‘unclear’ whether one type of exercise training regimen elicits a superior improvement in cardiorespiratory fitness relative to its counterpart.

  15. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources.

    Science.gov (United States)

    Loch, R A; Sobierajski, R; Louis, E; Bosgra, J; Bijkerk, F

    2012-12-17

    The single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly used multilayer optics and propose new material combinations selected for a high damage threshold. Our study demonstrates that the damage thresholds of multilayer optics can vary over a large range of incidence fluences and can be as high as several hundreds of mJ/cm(2). This strongly suggests that multilayer mirrors are serious candidates for damage resistant optics. Especially, multilayer optics based on Li(2)O spacers are very promising for use in current and future short-wavelength radiation sources.

  16. High Intensity Interval- vs Moderate Intensity- Training for Improving Cardiometabolic Health in Overweight or Obese Males: A Randomized Controlled Trial.

    Directory of Open Access Journals (Sweden)

    Gordon Fisher

    Full Text Available To compare the effects of six weeks of high intensity interval training (HIIT vs continuous moderate intensity training (MIT for improving body composition, insulin sensitivity (SI, blood pressure, blood lipids, and cardiovascular fitness in a cohort of sedentary overweight or obese young men. We hypothesized that HIIT would result in similar improvements in body composition, cardiovascular fitness, blood lipids, and SI as compared to the MIT group, despite requiring only one hour of activity per week compared to five hours per week for the MIT group.28 sedentary overweight or obese men (age, 20 ± 1.5 years, body mass index 29.5 ± 3.3 kg/m2 participated in a six week exercise treatment. Participants were randomly assigned to HIIT or MIT and evaluated at baseline and post-training. DXA was used to assess body composition, graded treadmill exercise test to measure cardiovascular fitness, oral glucose tolerance to measure SI, nuclear magnetic resonance spectroscopy to assess lipoprotein particles, and automatic auscultation to measure blood pressure.A greater improvement in VO2peak was observed in MIT compared to HIIT (11.1% vs 2.83%, P = 0.0185 in the complete-case analysis. No differences were seen in the intention to treat analysis, and no other group differences were observed. Both exercise conditions were associated with temporal improvements in % body fat, total cholesterol, medium VLDL, medium HDL, triglycerides, SI, and VO2peak (P < 0.05.Participation in HIIT or MIT exercise training displayed: 1 improved SI, 2 reduced blood lipids, 3 decreased % body fat, and 4 improved cardiovascular fitness. While both exercise groups led to similar improvements for most cardiometabolic risk factors assessed, MIT led to a greater improvement in overall cardiovascular fitness. Overall, these observations suggest that a relatively short duration of either HIIT or MIT training may improve cardiometabolic risk factors in previously sedentary overweight or

  17. High Intensity Interval- vs Moderate Intensity- Training for Improving Cardiometabolic Health in Overweight or Obese Males: A Randomized Controlled Trial.

    Science.gov (United States)

    Fisher, Gordon; Brown, Andrew W; Bohan Brown, Michelle M; Alcorn, Amy; Noles, Corey; Winwood, Leah; Resuehr, Holly; George, Brandon; Jeansonne, Madeline M; Allison, David B

    2015-01-01

    To compare the effects of six weeks of high intensity interval training (HIIT) vs continuous moderate intensity training (MIT) for improving body composition, insulin sensitivity (SI), blood pressure, blood lipids, and cardiovascular fitness in a cohort of sedentary overweight or obese young men. We hypothesized that HIIT would result in similar improvements in body composition, cardiovascular fitness, blood lipids, and SI as compared to the MIT group, despite requiring only one hour of activity per week compared to five hours per week for the MIT group. 28 sedentary overweight or obese men (age, 20 ± 1.5 years, body mass index 29.5 ± 3.3 kg/m2) participated in a six week exercise treatment. Participants were randomly assigned to HIIT or MIT and evaluated at baseline and post-training. DXA was used to assess body composition, graded treadmill exercise test to measure cardiovascular fitness, oral glucose tolerance to measure SI, nuclear magnetic resonance spectroscopy to assess lipoprotein particles, and automatic auscultation to measure blood pressure. A greater improvement in VO2peak was observed in MIT compared to HIIT (11.1% vs 2.83%, P = 0.0185) in the complete-case analysis. No differences were seen in the intention to treat analysis, and no other group differences were observed. Both exercise conditions were associated with temporal improvements in % body fat, total cholesterol, medium VLDL, medium HDL, triglycerides, SI, and VO2peak (P training displayed: 1) improved SI, 2) reduced blood lipids, 3) decreased % body fat, and 4) improved cardiovascular fitness. While both exercise groups led to similar improvements for most cardiometabolic risk factors assessed, MIT led to a greater improvement in overall cardiovascular fitness. Overall, these observations suggest that a relatively short duration of either HIIT or MIT training may improve cardiometabolic risk factors in previously sedentary overweight or obese young men, with no clear advantage between these

  18. Meeting standards of high-quality intensive care unit palliative care: Clinical performance and predictors

    Science.gov (United States)

    Penrod, Joan D.; Pronovost, Peter J.; Livote, Elayne E.; Puntillo, Kathleen A.; Walker, Amy S.; Wallenstein, Sylvan; Mercado, Alice F.; Swoboda, Sandra M.; Ilaoa, Debra; Thompson, David A.; Nelson, Judith E.

    2012-01-01

    Objectives High-quality care for intensive care unit patients and families includes palliative care. To promote performance improvement, the Agency for Healthcare Research and Quality’s National Quality Measures Clearinghouse identified nine evidence-based processes of intensive care unit palliative care (Care and Communication Bundle) that are measured through review of medical record documentation. We conducted this study to examine how frequently the Care and Communication Bundle processes were performed in diverse intensive care units and to understand patient factors that are associated with such performance. Design Prospective, multisite, observational study of performance of key intensive care unit palliative care processes. Settings A surgical intensive care unit and a medical intensive care unit in two different large academic health centers and a medical-surgical intensive care unit in a medium-sized community hospital. Patients Consecutive adult patients with length of intensive care unit stay ≥5 days. Interventions None. Measurements and Main Results Between November 2007 and December 2009, we measured performance by specified day after intensive care unit admission on nine care process measures: identify medical decision-maker, advance directive and resuscitation preference, distribute family information leaflet, assess and manage pain, offer social work and spiritual support, and conduct interdisciplinary family meeting. Multivariable regression analysis was used to determine predictors of performance of five care processes. We enrolled 518 (94.9%) patients and 336 (83.6%) family members. Performances on pain assessment and management measures were high. In contrast, interdisciplinary family meetings were documented for <20% of patients by intensive care unit day 5. Performance on other measures ranged from 8% to 43%, with substantial variation across and within sites. Chronic comorbidity burden and site were the most consistent predictors of care

  19. Solar induced long- and short-term variations of the cosmic ray intensity in the past, and predictions and opportunities for the future

    Science.gov (United States)

    McCracken, K. G.; McDonald, F. B.; Beer, J.

    2009-12-01

    The cosmogenic radionuclide data from the past 10,000 years, and the instrumental cosmic ray data since 1936 provide detailed information on the possible consequences of the present long and deep solar minimum. Furthermore, the cosmic ray transport equation has been used to estimate the strength of the interplanetary magnetic field (IMF) throughout the past 10,000 years. This paper presents a series of figures that document the behavior of both the cosmic radiation and the IMF at Earth in the past. In particular, the 11-year cycles in both quantities for the past 600 years are displayed; and estimates given of the cosmic ray spectrum at Earth for situations that history tells us may occur in the near future. Over the longer term, a minimum of the Hallstatt cycle (2200 yr periodicity) of solar activity occurred ~500 years ago and the Sun is now on a steadily rising plane of activity. The historic record shows that the cosmic ray intensity has decreased extremely rapidly after earlier prolonged deep minima and this suggests rapid and large changes in the heliospheric conditions that we may see replicated. The paper will also display data from the deep, isolated solar minimum of 1956 that exhibited unusual low energy cosmic ray fluxes, and a highly anomalous cosmic ray gradient in the inner heliosphere. Paleo-cosmic ray evidence will also be displayed of an episode of intense solar energetic particle (SEP) events in the interval of reduced solar activity, 1892-1900, that may possibly be repeated. If the present long, deep solar minimum is a precursor to a “Grand Minimum” such as the Dalton minimum, it will provide a much improved insight into the spectrum of the cosmic radiation in interstellar space, and to the cosmic ray modulation process in the heliosphere. With this in mind, the paper suggests key measurements, and speculates on experimental conditions that may be markedly different from those encountered in the instrumental era.

  20. Keynote address: High energy physics in 2014 and its future

    Indian Academy of Sciences (India)

    G Rajasekaran

    2016-02-01

    After a brief history, we focus on the present status of HEP and its possible future. Ideas to ensure a healthy growth of HEP in India are discussed. This involves a few major experimental projects in fundamental physics. None of these projects can succeed unless the crucial problem of manpower is solved. A few suggestions are offered towards this aim.

  1. Warm-up strategy and high-intensity endurance performance in trained cyclists

    DEFF Research Database (Denmark)

    Christensen, Peter Møller; Bangsbo, Jens

    2015-01-01

    PURPOSE: To evaluate the influence of warm-up exercise intensity and subsequent recovery on intense endurance performance, selected blood variables and the VO2 response. METHODS: Twelve highly trained male cyclists (VO2-max: 72.4±8.0·mL/min/kg, incremental-test peak power output (iPPO): 432±31 W......; means±SD) performed three warm-up strategies lasting 20 min before a 4-min maximal performance test (PT). Strategies consisted of moderate intensity exercise (50%iPPO) followed by 6 min of recovery (MOD6) or progressive-high intensity exercise (10-100%iPPO and 2x20-s sprints) followed by recovery for 6...... to HI20 (7.85±0.82 L; P=0.008) and MOD6 (7.90±0.74 L; P=0.012). CONCLUSIONS: Warm-up exercise including race-pace and sprint intervals combined with short recovery can reduce subsequent performance in a 4-min maximal test in highly trained cyclists. Thus, a reduced time at high exercise intensity...

  2. Study of ultra-high gradient wakefield excitation by intense ultrashort laser pulses in plasma

    Science.gov (United States)

    Kotaki, Hideyuki; Kando, Masaki; Oketa, Takatsugu; Masuda, Shinichi; Koga, James K.; Kondo, Shuji; Kanazawa, Shuhei; Yokoyama, Takashi; Matoba, Toru; Nakajima, Kazuhisa

    2002-10-01

    We investigate a laser wakefield excited by intense laser pulses, and the possibility of generating an intense bright electron source by an intense laser pulse. The coherent wakefield excited by 2 TW, 50 fs laser pulses in a gas-jet plasma around 1018 cm-3 is measured with a time-resolved frequency domain interferometer (FDI). The results show an accelerating wakefield excitation of 20 GeV/m with good coherency. This is the first time-resolved measurement of laser wakefield excitation in a gas-jet plasma. The experimental results agree with the simulation results and linear theory. The pump-probe interferometer system of FDI will be modified to the optical injection system as a relativistic electron beam injector. In 1D particle in cell simulation we obtain results of high quality intense electron beam generation.

  3. High-quality binary fringe generation via joint optimization on intensity and phase

    Science.gov (United States)

    Xiao, Yi; Li, Youfu

    2017-10-01

    There have been active studies on optimized dithering techniques to improve 3D shape measurement quality with defocused projectors. These techniques optimize the fringe quality in either phase domain or intensity domain according to their objective functions. Phase based optimization is direct and effective, but is sensitive to projector defocus levels. Intensity based optimization is robust to projector defocus levels, but it does not fully improve the phase quality. This paper presents a joint optimization technique to combine the merits of both the intensity and phase based optimization, which includes a pre-intensity optimization and a further optimization based on the synthesized error function. Then this technique is implemented in two frameworks, the whole-fringe optimization and the best-patch optimization, to generate binary fringe patterns. Both simulations and experiments show that the proposed technique can generate binary fringe patterns with high phase quality and robustness to projector defocus levels.

  4. Low-intensity red and infrared laser effects at high fluences on Escherichia coli cultures

    Energy Technology Data Exchange (ETDEWEB)

    Barboza, L.L.; Campos, V.M.A.; Magalhaes, L.A.G. [Instituto de Biologia Roberto Alcantara Gomes, Rio de Janeiro, RJ (Brazil). Departamento de Biofisica e Biometria; Paoli, F. [Universidade Federal de Juiz de Fora (UFJF), Juiz de Fora, MG (Brazil). Departamento de Morfologia; Fonseca, A.S., E-mail: adnfonseca@ig.com.br [Universidade Federal do Estado do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Departamento de Ciencias Fisiologicas

    2015-10-15

    Semiconductor laser devices are readily available and practical radiation sources providing wavelength tenability and high monochromaticity. Low-intensity red and near-infrared lasers are considered safe for use in clinical applications. However, adverse effects can occur via free radical generation, and the biological effects of these lasers from unusually high fluences or high doses have not yet been evaluated. Here, we evaluated the survival, filamentation induction and morphology of Escherichia coli cells deficient in repair of oxidative DNA lesions when exposed to low-intensity red and infrared lasers at unusually high fluences. Cultures of wild-type (AB1157), endonuclease III-deficient (JW1625-1), and endonuclease IV-deficient (JW2146-1) E. coli, in exponential and stationary growth phases, were exposed to red and infrared lasers (0, 250, 500, and 1000 J/cm{sup 2}) to evaluate their survival rates, filamentation phenotype induction and cell morphologies. The results showed that low-intensity red and infrared lasers at high fluences are lethal, induce a filamentation phenotype, and alter the morphology of the E. coli cells. Low-intensity red and infrared lasers have potential to induce adverse effects on cells, whether used at unusually high fluences, or at high doses. Hence, there is a need to reinforce the importance of accurate dosimetry in therapeutic protocols. (author)

  5. High-intensity exercise training produces morphological and biochemical changes in adrenal gland of mice.

    Science.gov (United States)

    Bartalucci, A; Ferrucci, M; Fulceri, F; Lazzeri, G; Lenzi, P; Toti, L; Serpiello, F R; La Torre, A; Gesi, M

    2012-06-01

    The effects of training are dependent on complex, adaptive changes which are induced by acute physical exercise at different levels. In particular, evidence shows that the hypothalamus-pituitary-adrenocortical axis, as well as the sympatho-adrenomedullary system, is mainly involved in mediating the physiological effects of physical exercise. The aim of the present study was to investigate, through a morphological and biochemical approach, the effects of training on the adrenal gland of mice, following two different protocols consisting of either low- or high-intensity training. Mice were run daily on a motorised treadmill for 8 weeks, at a velocity corresponding to 60% (low-intensity exercise) or 90% (high-intensity exercise) of the maximal running velocity previously determined by an incremental exercise test. We found that physical exercise produced an increase in the adrenal gland size compared with the control (sedentary) mice. The increase was 31.04% for mice that underwent high-intensity exercise and 10.08% for mice that underwent low intensity exercise, and this appeared to be the result of an increase in the area of both the adrenal cortex and adrenal medulla. Morphological analysis of the adrenal cortex showed that both types of exercise produced an increase in cytoplasmic vacuoles in steroidogenic cells, appearing more abundant after high-intensity exercise. No change was found in the reticulate zone. In the adrenal medulla, despite the absence of morphological changes, immunohistochemistry for tyrosine hydroxylase, dopamine β-hydroxylase and phenyl-ethanolamine-N-methyltransferase demonstrated an increased immunopositivity for these cathecolamine-synthesizing enzymes after intense exercise. These results were confirmed by immunoblot accompanied by densitometric analysis.

  6. Formation of Nanoscale Intermetallic Phases in Ni Surface Layer at High Intensity Implantation of Al Ions

    Institute of Scientific and Technical Information of China (English)

    I.A.Bozhko; S.V.Fortuna; I.A.Kurzina; I.B.Stepanov; E.V.Kozlov; Yu.P. Sharkeev

    2004-01-01

    The results of experimental study of nanoscale intermetallic formation in surface layer of a metal target at ion implantation are presented. To increase the thickness of the ion implanted surface layer the high intensive ion implantation is used. Compared with the ordinary ion implantation, the high intensive ion implantation allows a much thicker modified surface layer. Pure polycrystalline nickel was chosen as a target. Nickel samples were irradiated with Al ions on the vacuum-arc ion beam and plasma flow source "Raduga-5". It was shown that at the high intensity ion implantation the fine dispersed particles of Ni3Al, NiAl intermetallic compounds and solid solution Al in Ni are formed in the nickel surface layer of 200 nm and thicker. The formation of phases takes place in complete correspondence with the Ni-Al phase diagram.

  7. The high intensity solar cell - Key to low cost photovoltaic power

    Science.gov (United States)

    Sater, B. L.; Goradia, C.

    1975-01-01

    This paper discusses the problems associated with conventional solar cells at high intensities and presents the design considerations and performance characteristics of the 'high intensity' (HI) solar cell which appears to eliminate the major problems. Test data obtained at greater than 250 AM1 suns gave a peak output power density of 2 W per sq cm at an efficiency exceeding 6% with an unoptimized cell operating at over 100 C. It appears that operation at 1000 AM1 suns at efficiencies greater than 10% is possible. At 1000 AM1 suns and 10% efficiency, the HI cell manufacturing cost is estimated to be $0.25/watt, with multi-megawatt annual production capability already existing within the industrial sector. A high intensity solar system was also analyzed to determine its cost effectiveness and to assess the benefits of further improving HI cell efficiency.

  8. The clinical study on high intensity zone of magnetic resonance imaging using Scolopendrid Aquacupuncture.

    Directory of Open Access Journals (Sweden)

    Jeong-a Lim

    2006-12-01

    Full Text Available Objective : This study was designed to find out the effect of scolopendrid aquacupuncture on low back pain with or without sciatica showing high intensity zone of magnetic resonance imaging. Methods : The 30 patients who had a diagnosis of high intensity zone by lumbar-MRI and admitted to Gwangju oriental medical hospital in wonkwang university from January 2005 to August 2004 were observed. The symptom of inpatients is low back pain with or without sciatica. We treated 30 patients by scolopendrid aquacupuncture besides the general conservative treatment of oriental medicine. Results and Conclusion : The scolopendrid aquacupuncture treatment led to improvement in the pain and symptom of disability as determined by all efficacy measures. After scolopendrid aquacupuncture treatment, there was improvement in VAS, ROM and SLRT. This results suggest that scolopendrid aquacupuncture is good method for treatment of low back pain with or without sciatica showing high intensity zone of magnetic resonance imaging.

  9. Changes in satellite cells in human skeletal muscle after a single bout of high intensity exercise

    DEFF Research Database (Denmark)

    Crameri, Regina M; Langberg, Henning; Magnusson, Peter

    2004-01-01

    desmin or dystrophin, were not observed, and hence did not appear to induce the expression of either N-CAM or FA1. We therefore propose that satellite cells can be induced to re-enter the cell growth cycle after a single bout of unaccustomed high intensity exercise. However, a single bout of exercise......No studies to date have reported activation of satellite cells in vivo in human muscle after a single bout of high intensity exercise. In this investigation, eight individuals performed a single bout of high intensity exercise with one leg, the contralateral leg being the control. A significant...... increase in mononuclear cells staining for the neural cell adhesion molecule (N-CAM) and fetal antigen 1 (FA1) were observed within the exercised human vastus lateralis muscle on days 4 and 8 post exercise. In addition, a significant increase in the concentration of the FA1 protein was determined...

  10. Repeated high-intensity exercise modulates Ca(2+) sensitivity of human skeletal muscle fibers

    DEFF Research Database (Denmark)

    Gejl, K D; Hvid, L G; Willis, S J;

    2016-01-01

    The effects of short-term high-intensity exercise on single fiber contractile function in humans are unknown. Therefore, the purposes of this study were: (a) to access the acute effects of repeated high-intensity exercise on human single muscle fiber contractile function; and (b) to examine whether...... the fourth sprint with respect to Ca(2+) sensitivity and maximal Ca(2+) -activated force. To investigate the oxidative effects of exercise on single fiber contractile function, a subset of fibers was incubated with dithiothreitol (DTT) before analysis. Ca(2+) sensitivity was enhanced by exercise in both MHC...... I (17%, P exercise. In conclusion, repeated high-intensity exercise increased Ca(2+) sensitivity in both MHC I and MHC II...

  11. The intensity dependence of surface recombination in high concentration solar cells with charge induced passivation

    Science.gov (United States)

    Gray, J. L.; Schwartz, R. J.; Lundstrom, M. S.; Nasby, R. D.

    High intensity solar cells which are designed to minimize series resistance and shadowing losses, frequently employ an illuminated surface which is relatively far removed from the collecting junctions. This requires that the surface be well passivated to minimize surface recombination. One technique frequently employed to minimize surface recombination is to incorporate a fixed charge in the passivating oxide. This work shows that at sufficiently high intensities the surface recombination can increase dramatically. This results in a reduction in the high intensity collection efficiency. A comparison of the collection efficiency of interdigitated back contact cells and etched multiple vertical junction cells is given which shows that EMVJ cells are less sensitive to this effect than IBC cells.

  12. High-intensity running in English FA Premier League soccer matches

    DEFF Research Database (Denmark)

    Bradley, Paul S.; Sheldon, William; Wooster, Blake

    2009-01-01

    The aims of this study were to (1) determine the activity profiles of a large sample of English FA Premier League soccer players and (2) examine high-intensity running during elite-standard soccer matches for players in various playing positions. Twenty-eight English FA Premier League games were.......01), attackers (2341 m, s=575, P game, high-intensity running distance was approximately 20% less than in the first 15-min period for wide midfielders (467 m, s=104 vs. 589 m, s=134, P ....01) and without ball possession (229 m, s=85 vs. 278 m, s=97, P game. Mean recovery time between very high-intensity running bouts was 72 s (s=28), with a 28% longer recovery time during the last 15 min than the first 15 min of the game (83 s, s=26 vs...

  13. Stimulated recombination of antiproton and positron with ultra-short ultra-high intensity laser pulse

    CERN Document Server

    Ryabinina, M V

    2003-01-01

    Ionization of hydrogen atom in the field of high-intense ultra-short femto-second laser pulse recently became the subject of comprehensive theoretical approaches. On the other hand, there exists experimental evidence that short electric pulses can effectively stimulate electron-proton (as well as antiproton-positron) recombination to high-level (Rydberg) state. In this paper we present the results of the theoretical estimations of antiproton-positron recombination cross-section in cold mixed plasmas in traps in the conditions of ATHENA/ATRAP experiments in CERN under the action of sub-fs laser pulse with TW intensity. (2 refs).

  14. Threshold Stress Intensity of Hydrogen-Induced Cracking and Stress Corrosion Cracking of High Strength Steel

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The threshold stress intensity of stress corrosion cracking (SCC) for 40CrMo steel in 3.5 % NaCl solution decreased exponentially with the increase of yield strength. The threshold stress intensity of hydrogen-induced cracking during dynamical charging for 40CrMo steel decreased linearly with the logarithm of the concentration of diffusible hydrogen. This equation was also applicable to SCC of high strength steel in aqueous solution. The critical hydrogen enrichment concentration necessary for SCC of high strength steel in water decreased exponentially with the increase of yield strength. Based on the results, the relationship between KISCC and σys could be deduced.

  15. Design concept of radiation control system for the high intensity proton accelerator facility

    Energy Technology Data Exchange (ETDEWEB)

    Miyamoto, Yukihiro; Ikeno, Koichi; Akiyama, Shigenori; Harada, Yasunori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-11-01

    Description is given for the characteristic radiation environment for the High Intensity Proton Accelerator Facility and the design concept of the radiation control system of it. The facility is a large scale accelerator complex consisting of high energy proton accelerators carrying the highest beam intensity in the world and the related experimental facilities and therefore provides various issues relevant to the radiation environment. The present report describes the specifications for the radiation control system for the facility, determined in consideration of these characteristics. (author)

  16. Rapid response of soil fungal communities to low and high intensity fire

    Science.gov (United States)

    Smith, Jane E.; Cowan, Ariel D.; Reazin, Chris; Jumpponen, Ari

    2016-04-01

    Contemporary fires have created high-severity burn areas exceeding historical distributions in forests in the western United States. Until recently, the response of soil ecosystems to high intensity burns has been largely unknown. In complementary studies, we investigated the environmental effect of extreme soil heating, such that occurs with the complete combustion of large down wood during wildfires, on soil fungi and nutrients. We used TRFLP and next generation sequencing (Illumina MiSeq) to investigate the fungal communities. During the burning of large down wood, temperatures lethal to fungi were detected at 0-cm, 5-cm, and 10-cm depths in soils compared to 0-cm depth in soils receiving low intensity broadcast burns. We compared the soil fungal diversity in ten high intensity burned plots paired with adjacent low intensity burned plots before and one week after at 0-10 cm soil depth. Nonmetric Multidimensional Scaling (NMS) ordinations and analyses of taxon frequencies reveal a substantial community turnover and corresponding near complete replacement of the dominant basidiomycetes by ascomycetes in high intensity burns. These coarse-level taxonomic responses were primarily attributable to a few fire-responsive (phoenicoid) fungi, particularly Pyronema sp. and Morchella sp., whose frequencies increased more than 100-fold following high intensity burns. Pinus ponderosa seedlings planted one week post-burn were harvested after four months for EMF root tip analysis. We found: a) greater differences in soil properties and nutrients in high intensity burned soils compared to low intensity burned and unburned soils; b) no differences in EMF richness and diversity; and c) weak differences in community composition based on relative abundance between unburned and either burn treatments. These results confirm the combustion of large downed wood can alter the soil environment directly beneath it. However, an EMF community similar to low burned soils recolonized high

  17. [Metabolic response to high intensity exercise training in sedentary hyperglycemic and hypercholesterolemic women].

    Science.gov (United States)

    Alvarez L, Cristian; Ramírez-Campillo, Rodrigo; Flores O, Marcelo; Henríquez-Olguín, Carlos; Campos J, Christian; Carrasco, Vanesa; Martínez S, Cristian; Celis-Morales, Carlos

    2013-10-01

    High intensity training could be an effective way of improving health on individuals at high metabolic risk. To investigate the effects of a high intensity training intervention on metabolic-related markers in sedentary women at high metabolic risk. Forty six sedentary women with a body mass index (BMI) over 25 kg/m² were assigned to four groups, according to their metabolic profile; hyperglycemia (H, n = 12), hyperglycemia/hypercholesterolemia (HH, n = 13), normoglycemia (N, n = 10) and normoglycemia/hypercholesterolemia (NH, n = 11). For 12 weeks and five days per week, subjects performed seven intervals of high intensity training (20 to 30 seconds) during a training session of 20 minutes. Anthropometric (body weight, body mass index (BMI), waist circumference) and metabolic variables (glucose, total cholesterol, LDL, HDL and TG) were measured at baseline, at 6 and 12 weeks of intervention. BMI and waist circumference decreased significantly after 12 weeks of intervention. Similarly, glucose decreased significantly after 12 weeks of intervention in all groups. The reduction was of higher magnitude in those groups with hyperglycemia (H = -16%, HH = -22%, N = -7,5%, NH = -9,6%). However, lipid profile (TG, total cholesterol, LDL and HDL) improved significantly only in the hypercholesterolemic groups. Physical activity programs incorporating high intensity training can improve glucose and lipid profile in women with metabolic disorders. Moreover, this benefit is greatest in those individuals with highest metabolic burden.

  18. Effects of high-intensity interval training on the VO2 response during severe exercise.

    Science.gov (United States)

    Duffield, Rob; Edge, Johann; Bishop, David

    2006-06-01

    This study examined the effect of high-intensity interval training on the VO2 response during severe, constant-load exercise. Prior to, and following training, 10 females (V O2 peak 37.4+/-6.0 mL kg-1 min-1) performed a graded exercise test to determine VO2 peak and lactate threshold (LT) and a 6 min cycle test (CT) at the pre-training VO2 peak intensity. Training involved high-intensity intervals (2 min work, 1 min rest) performed 3x week for 8 weeks. Breath-by-breath data from 0 to 6 min during the CT were smoothed using 5s averages and fit to a bi-exponential model starting from 20s. Training resulted in significant improvements in VO2 max (2.34+/-0.37-2.78+/-0.30 L min-1), power at VO2 max (170+/-26-204+/-25 W) and power at LT (113+/-17-136+/-20 W) (pVO2 response showed a significant increase in the amplitude of the primary phase (A1) (1396+/-103-1695+/-100 mL min-1; pVO2 (VO2 EE), with no difference (p>0.05) in the time constants of either phase or the amplitude of the slow component (318+/-67-380+/-48 mL; p=0.15). In conjunction, accumulated oxygen deficit (AOD) (43.7+/-9.8-17.2+/-2.8 mL O2 eq kg-1) and anaerobic contribution to the CT (19.4+/-4.4-7.2+/-1.2%) were significantly reduced. In contrast to previous moderate-intensity research, a high-intensity interval training program increased A1 and VO2 EE for the same absolute exercise intensity, decreasing the AOD during a severe-intensity CT.

  19. High-performance computing at NERSC: Present and future

    Energy Technology Data Exchange (ETDEWEB)

    Koniges, A.E.

    1995-07-01

    The author describes the new T3D parallel computer at NERSC. The adaptive mesh ICF3D code is one of the current applications being ported and developed for use on the T3D. It has been stressed in other papers in this proceedings that the development environment and tools available on the parallel computer is similar to any planned for the future including networks of workstations.

  20. The Benefits of High-Intensity Functional Training Fitness Programs for Military Personnel.

    Science.gov (United States)

    Haddock, Christopher K; Poston, Walker S C; Heinrich, Katie M; Jahnke, Sara A; Jitnarin, Nattinee

    2016-11-01

    High intensity functional training (HIFT) programs are designed to address multiple fitness domains, potentially providing improved physical and mental readiness in a changing operational environment. Programs consistent with HIFT principals such as CrossFit, SEALFIT and the US Marine Corps' High Intensity Tactical Training (HITT) are increasingly popular among military personnel. The goal of HIFT programs is to produce high levels of cardiorespiratory fitness, endurance and strength that exceed those achieved by following current physical activity recommendations. Given the investment in and popularity of HIFT in the military, it is important to consider the potential impact of this approach to fitness training for the health of military personnel and their risk of training injury. In a previous report in this journal, we addressed the question of whether HIFT was associated with higher injury rates compared to other exercise programs. We argued that concerns about the injury potential of HIFT exercise programs were not supported by the scientific literature to date, although additional research was needed to directly compare injury rates in approaches such as CrossFit to traditional military fitness programs. In this article we will review the scientific data on the practical, health and fitness benefits of HIFT exercise programs for military populations. Practical benefits to HIFT exercise programs include shorter training times and volumes, exercises which simulate combat tasks, lower equipment costs, reduced potential for boredom and adaptation as a result of constant variation, less injury potential compared to high volume endurance training, and scalability to all fitness levels and rehabilitation needs. For instance, HIFT training volumes are typically between 25% to nearly 80% less than traditional military fitness programs without reductions in fitness outcomes. HIFT program also provide an impressive range of health benefits such as the promotion of

  1. Rainfall intensity characteristics at coastal and high altitude stations in Kerala

    Indian Academy of Sciences (India)

    V Sasi Kumar; S Sampath; P V S S K Vinayak; R Harikumar

    2007-10-01

    Rainfall intensities measured at a few stations in Kerala during 2001 –2005 using a disdrometer were found to be in reasonable agreement with the total rainfall measured using a manual rain gauge. The temporal distributions of rainfall intensity at different places and during different months show that rainfall is of low intensity (> 10 mm/hr),65%to 90%of the time.This could be an indication of the relative prevalence of stratiform and cumuliform clouds.Rainfall was of intensity > 5 mm/hr for more than 95%of the time in Kochi in July 2002,which was a month seriously deficient in rainfall,indicating that the deficiency was probably due to the relative absence of cumuliform clouds.Cumulative distribution graphs are also plotted and fitted with the Weibull distribution.The fit parameters do not appear to have any consistent pattern. The higher intensities also contributed signi ficantly to total rainfall most of the time,except in Munnar (a hill station). In this analysis also,the rainfall in Kochi in July 2002 was found to have less presence of high intensities. This supports the hypothesis that the rainfall de ficiency was probably caused by the absence of conditions that favoured the formation of cumuliform clouds.

  2. Novel high-energy physics studies using intense lasers and plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Leemans, Wim P. [Univ. of California, Berkeley, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bulanov, Stepan [Univ. of California, Berkeley, CA (United States); Esarey, Eric [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Schroeder, Carl [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-06-29

    In the framework of the project “Novel high-energy physics studies using intense lasers and plasmas” we conducted the study of ion acceleration and “flying mirrors” with high intensity lasers in order to develop sources of ion beams and high frequency radiation for different applications. Since some schemes of laser ion acceleration are also considered a good source of “flying mirrors”, we proposed to investigate the mechanisms of “mirror” formation. As a result we were able to study the laser ion acceleration from thin foils and near critical density targets. We identified several fundamental factors limiting the acceleration in the RPA regime and proposed the target design to compensate these limitations. In the case of near critical density targets, we developed a concept for the laser driven ion source for the hadron therapy. Also we studied the mechanism of “flying mirror” generation during the intense laser interaction with thin solid density targets. As for the laser-based positron creation and capture we initially proposed to study different regimes of positron beam generation and positron beam cooling. Since the for some of these schemes a good quality electron beam is required, we studied the generation of ultra-low emittance electron beams. In order to understand the fundamental physics of high energy electron beam interaction with high intensity laser pulses, which may affect the efficient generation of positron beams, we studied the radiation reaction effects.

  3. Beam Dynamics Observations of the 2015 High Intensity Scrubbing Runs at the Cern Sps

    CERN Document Server

    Bartosik, Hannes; Li, Kevin; Mether, Lotta; Romano, Annalisa; Rumolo, Giovanni; Schenk, Michael

    2016-01-01

    Beam quality degradation caused by e-cloud effects has been identified as one of the main performance limitations for high intensity LHC beams with 25 ns bunch spacing in the SPS. In view of the beam parameters targeted with the LHC injectors upgrade (LIU) project, about two weeks of SPS machine time in 2015 were devoted to dedicated scrubbing runs with high intensity LHC 25 ns and dedicated 'doublet' beams in order to study the achievable reduction of e-cloud effects and quantify the consequent beam performance improvements. This paper describes the main observations concerning the coherent instabilities and beam dynamics limitations encountered as well as a detailed characterisation of the performance reach with the highest beam intensity presently available from the pre-injectors.

  4. Oral versus Nasal Breathing during Moderate to High Intensity Submaximal Aerobic Exercise

    Directory of Open Access Journals (Sweden)

    Chase O. LaComb

    2017-01-01

    Full Text Available Introduction: When comparing oral breathing versus nasal breathing, a greater volume of air can be transported through the oral passageway but nasal breathing may also have benefits at submaximal exercise intensities. Purpose: The purpose of this study was to determine breathing efficiency during increasing levels of submaximal aerobic exercise. Methods: Nineteen individuals (males N=9, females N=10 completed a test for maximal oxygen consumption (VO2max and on separate days 4-min treadmill runs at increasing submaximal intensities (50%, 65%, and 80% of VO2max under conditions of oral breathing or nasal breathing. Respiratory (respiration rate [RR], pulmonary ventilation [VE], metabolic (oxygen consumption [VO2], carbon dioxide production [VCO2] and efficiency measures (ventilatory equivalents for oxygen [Veq×O2-1] and carbon dioxide [Veq×CO2-1] were obtained. Data were analyzed utilizing a 2 (sex x 2 (condition x3 (intensity repeated measures ANOVA with significance accepted at p≤0.05. Results: Significant interactions existed between breathing mode and intensity such that oral breathing resulted in greater RR, VE, VO2, and VCO2 at all three submaximal intensities (p<.05.  Veq×O2-1 and Veq×CO2-1 presented findings that nasal breathing was more efficient than oral breathing during the 65% and 80% VO2max intensities (p<0.05. Conclusion: Based on this analysis, oral breathing provides greater respiratory and metabolic volumes during moderate and moderate-to-high submaximal exercise intensities, but may not translate to greater respiratory efficiency. However when all variables are considered together, it is likely that oral breathing represents the more efficient mode, particularly at higher exercise intensities.

  5. High-intensity interval training (HIIT for patients with chronic diseases

    Directory of Open Access Journals (Sweden)

    Leanna M. Ross

    2016-06-01

    Full Text Available Exercise training provides physiological benefits for both improving athletic performance and maintaining good health. Different exercise training modalities and strategies exist. Two common exercise strategies are high-intensity interval training (HIIT and moderate-intensity continuous exercise training (MCT. HIIT was first used early in the 20th century and popularized later that century for improving performance of Olympic athletes. The primary premise underlying HIIT is that, compared to energy expenditure-matched MCT, a greater amount of work is performed at a higher intensity during a single exercise session which is achieved by alternating high-intensity exercise intervals with low-intensity exercise or rest intervals. Emerging research suggests that this same training method can provide beneficial effects for patients with a chronic disease and should be included in the comprehensive medical management plan. Accordingly, a major consideration in developing an individual exercise prescription for a patient with a chronic disease is the selection of an appropriate exercise strategy. In order to maximize exercise training benefits, this strategy should be tailored to the individual's need. The focus of this paper is to provide a brief summary of the current literature regarding the use of HIIT to enhance the functional capacity of individuals with cardiovascular, pulmonary, and diabetes diseases.

  6. High-intensity interval training (HIIT) for patients with chronic diseases

    Institute of Scientific and Technical Information of China (English)

    Leanna M. Ross; Ryan R. Porter; J. Larry Durstine

    2016-01-01

    Exercise training provides physiological benefits for both improving athletic performance and maintaining good health. Different exercise training modalities and strategies exist. Two common exercise strategies are high-intensity interval training (HIIT) and moderate-intensity continuous exercise training (MCT). HIIT was first used early in the 20th century and popularized later that century for improving performance of Olympic athletes. The primary premise underlying HIIT is that, compared to energy expenditure-matched MCT, a greater amount of work is performed at a higher intensity during a single exercise session which is achieved by alternating high-intensity exercise intervals with low-intensity exercise or rest intervals. Emerging research suggests that this same training method can provide beneficial effects for patients with a chronic disease and should be included in the comprehensive medical management plan. Accordingly, a major consideration in developing an individual exercise prescription for a patient with a chronic disease is the selection of an appropriate exercise strategy. In order to maximize exercise training benefits, this strategy should be tailored to the individual’s need. The focus of this paper is to provide a brief summary of the current literature regarding the use of HIIT to enhance the functional capacity of individuals with cardiovascular, pulmonary, and diabetes diseases.

  7. High Intensity Interval Training in Handcycling : The Effects of a 7 Week Training Intervention in Able-bodied Men

    NARCIS (Netherlands)

    Schoenmakers, Patrick; Reed, Kate; Van Der Woude, Luc; Hettinga, Florentina J.

    2016-01-01

    INTRODUCTION: In lower body endurance training, quantities of both moderate intensity continuous training (MICT) and high intensity interval training (HIIT) can lead to an improved physiological capacity and performance. Limited research is available regarding the endurance and muscular capacity of

  8. Effects of high-intensity interval versus mild-intensity endurance training on metabolic phenotype and corticosterone response in rats fed a high-fat or control diet.

    Science.gov (United States)

    Shen, Youqing; Huang, Guoyuan; McCormick, Bryan P; Song, Tao; Xu, Xiangfeng

    2017-01-01

    The aim of the present study was to compare the effects of high-intensity interval training (HI) to mild-intensity endurance training (ME), combined with a high-fat diet (HFD) or control diet (CD) on metabolic phenotype and corticosterone levels in rats. Fifty-three rats were randomized to 6 groups according to diet and training regimen as follows: CD and sedentary (CS, n = 11), CD and ME (CME, n = 8), CD and HI (CHI, n = 8), HFD and sedentary (HS, n = 10), HFD and ME (HME, n = 8), and HFD and HI (HHI, n = 8). All exercise groups were trained for 10 weeks and had matched running distances. Dietary intake, body composition, blood metabolites, and corticosterone levels were measured. Histological lipid droplets were observed in the livers. The HFD led to hyperglycemia, hyperlipidemia and higher body fat (all, P 0.06), as well as higher corticosterone levels (P training improved fat weight, glucose, and lipid profiles, and reduced corticosterone levels (P training compared to ME training. Reductions in HFD-induced body weight gain, blood glucose and lipid profiles, and corticosterone levels, as well as improvements in QUICKI were better with HHI compared to HME. Correlation analyses revealed that corticosterone levels were significantly associated with phenotype variables (P training, HI training contributes to greater improvements in metabolic and corticosterone responses, leading to a greater reduction in susceptibility to HFD-induced disorders.

  9. High Energy Colliding Beams; What Is Their Future?

    CERN Document Server

    Richter, Burton

    2014-01-01

    The success of the first few years of LHC operations at CERN, and the expectation of more to come as the LHC performance improves, are already leading to discussions of what should be next for both proton-proton and electron-positron colliders. In this discussion I see too much theoretical desperation caused by the so far unsuccessful hunt for what is beyond the Standard Model, and too little of the necessary interaction of the accelerator, experimenter, and theory communities necessary for a scientific and engineering success. Here, I give my impressions of the problem, its possible solution, and what is needed to have both a scientifically productive and financially viable future.

  10. High flexible Hydropower Generation concepts for future grids

    Science.gov (United States)

    Hell, Johann

    2017-04-01

    The ongoing changes in electric power generation are resulting in new requirements for the classical generating units. In consequence a paradigm change in operation of power systems is necessary and a new approach in finding solutions is needed. The presented paper is dealing with the new requirements on current and future energy systems with the focus on hydro power generation. A power generation landscape for some European regions is shown and generation and operational flexibility is explained. Based on the requirements from the Transmission System Operator in UK, the transient performance of a Pumped Storage installation is discussed.

  11. Moderate-to-high intensity aerobic exercise in patients with mild to moderate Alzheimer's disease

    DEFF Research Database (Denmark)

    Frederiksen, Kristian S; Sobol, Nanna; Beyer, Nina

    2014-01-01

    OBJECTIVES: Physical exercise may modulate neuropathology and symptoms of Alzheimer's disease (AD). This pilot study assessed the feasibility of conducting a study of moderate-to-high intensity aerobic exercise in home-dwelling patients with mild AD. METHODS: An uncontrolled preintervention...

  12. High Intensity Pressure Noise Transmission in Human Ear: A Three Dimensional Simulation Study

    Science.gov (United States)

    Hawa, Takumi; Gan, Rong; Leckness, Kegan

    2015-03-01

    High intensity pressure noise generated by explosions and jet engines causes auditory damage and hearing loss of the military service personals, which are the most common disabilities in the veterans. Authors have investigated the high intensity pressure noise transmission from the ear canal to middle ear cavity. A fluid-structure interaction with a viscoelastic model for the tympanic membrane (TM) as well as the ossicular chain has been considered in the study. For the high intensity pressure simulation the geometry of the ear was based on a 3D finite element (FE) model of the human ear reported by Gan et al. (Ann Biomed Eng 2004). The model consists of the ear canal, TM, ossicular chain, and the middle ear cavity. The numerical approach includes two steps: 1) FE based finite-volume method simulation to compute pressure distributions in the ear canal and the middle ear cavity using CFX; and 2) FE modeling of TM and middle ear ossicles in response to high intensity sound using multi-physics analysis in ANSYS. The simulations provide the displacement of the TM/ossicular chain and the pressure fields in the ear canal and the middle ear cavity. These results are compared with human temporal bone experimental data obtained in our group. This work was supported by DOD W81XWH-14-1-0228.

  13. Edward Teller medal lecture: high intensity lasers and the road to ignition

    Energy Technology Data Exchange (ETDEWEB)

    Key, M.H.

    1997-06-02

    There has been much progress in the development of high intensity lasers and in the science of laser driven inertially confined fusion such that ignition is now a near term prospect. This lecture reviews the field with particular emphasis on areas of my own involvement.

  14. Dose estimation and shielding calculation for X-ray hazard at high intensity laser facilities

    Science.gov (United States)

    Qiu, Rui; Zhang, Hui; Yang, Bo; James, C. Liu; Sayed, H. Rokni; Michael, B. Woods; Li, Jun-Li

    2014-12-01

    An ionizing radiation hazard produced from the interaction between high intensity lasers and solid targets has been observed. Laser-plasma interactions create “hot” electrons, which generate bremsstrahlung X-rays when they interact with ions in the target. However, up to now only limited studies have been conducted on this laser-induced radiological protection issue. In this paper, the physical process and characteristics of the interaction between high intensity lasers and solid targets are analyzed. The parameters of the radiation sources are discussed, including the energy conversion efficiency from laser to hot electrons, hot electron energy spectrum and electron temperature, and the bremsstrahlung X-ray energy spectrum produced by hot electrons. Based on this information, the X-ray dose generated with high-Z targets for laser intensities between 1014 and 1020 W/cm2 is estimated. The shielding effects of common shielding items such as the glass view port, aluminum chamber wall and concrete wall are also studied using the FLUKA Monte Carlo code. This study provides a reference for the dose estimation and the shielding design of high intensity laser facilities.

  15. Burden of highly resistant microorganisms in a Dutch intensive care unit

    NARCIS (Netherlands)

    Aardema, H.; Arends, J. P.; de Smet, A. M. G. A.; Zijlstra, J. G.

    2015-01-01

    Background: The occurrence of highly resistant microorganisms (HRMOs) is a major threat to critical care patients, leading to worse outcomes, need for isolation measures, and demand for second-line or rescue antibiotics. The aim of this study was to quantify the burden of HRMOs in an intensive care

  16. Windowless microfluidic platform based on capillary burst valves for high intensity x-ray measurements

    DEFF Research Database (Denmark)

    Vig, Asger Laurberg; Haldrup, Kristoffer; Enevoldsen, Nikolaj Brandt;

    2009-01-01

    We propose and describe a microfluidic system for high intensity x-ray measurements. The required open access to a microfluidic channel is provided by an out-of-plane capillary burst valve (CBV). The functionality of the out-of-plane CBV is characterized with respect to the diameter of the window...

  17. Selected List of Low Energy Beam Transport Facilities for Light-Ion, High-Intensity Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Prost, L. R. [Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)

    2016-02-17

    This paper presents a list of Low Energy Beam Transport (LEBT) facilities for light-ion, high-intensity accelerators. It was put together to facilitate comparisons with the PXIE LEBT design choices. A short discussion regarding the importance of the beam perveance in the choice of the transport scheme follows.

  18. A numerical and experimental investigation of the performance of sound intensity probes at high frequencies

    DEFF Research Database (Denmark)

    Jacobsen, Finn; Cutanda, Vicente; Juhl, Peter Møller

    1998-01-01

    The high-frequency performance of a p-p intensity probe with a solid spacer between the two microphones is examined. It is shown theoretically and verified experimentally that with a spacer length that equals the diameter of the microphones, the finite difference error is almost perfectly cancelled...

  19. Triggered Drug Release from Superhydrophobic Meshes using High-Intensity Focused Ultrasound

    OpenAIRE

    Yohe, Stefan T.; Kopechek, Jonathan A.; Porter, Tyrone M; Colson, Yolonda L.; Grinstaff, Mark W.

    2013-01-01

    Application of high-intensity focused ultrasound to drug-loaded superhydrophobic meshes affords triggered drug release by displacing an entrapped air layer. The air layer within the superhydrophobic meshes is characterized using direct visualization and B-mode imaging. Drug-loaded superhydrophobic meshes are cytotoxic in an in vitro assay after ultrasound treatment.

  20. Towards MR-guided high intensity focused ultrasound ablation of liver tumors

    NARCIS (Netherlands)

    Wijlemans, J.W.

    2015-01-01

    Magnetic Resonance-guided High Intensity Focused Ultrasound (MR-HIFU) is a promising technique which can be used for completely non-invasive tissue ablation. The converging ultrasound beam penetrates the skin and subcutaneous tissues with damage, while heating the tissue only in the focal point. The

  1. MRI-guided High-Intensity Focused Ultrasound of Breast Cancer

    NARCIS (Netherlands)

    Merckel, L.G.

    2014-01-01

    Magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for completely noninvasive tumor ablation. This thesis focuses on its application for the treatment of patients with breast cancer. The first part of the thesis describes the role of breast MRI for

  2. Work in progress at the North Area High Intensity Facility (NAHIF)

    CERN Document Server

    1979-01-01

    The photo shows the exit of the two MBN-type magnets in tunnel TDC85 (upstream of TCC8), used to 'switch' the primary proton beam either towards target T8 (to the left) or onto target T10 (straight) to produce the H10 or the F12 (high-intensity electron/gamma) beam, respectively.

  3. 21 CFR 1040.30 - High-intensity mercury vapor discharge lamps.

    Science.gov (United States)

    2010-04-01

    ... mercury and that is contained within an outer envelope. (2) Advertisement means any catalog, specification... ballast is an inductive reactor designed to have the operating characteristics as listed in Section 7 in... advertisement. Advertising for any high-intensity mercury vapor discharge lamp that does not comply...

  4. Bone metastasis treatment using magnetic resonance-guided high intensity focused ultrasound

    NARCIS (Netherlands)

    Yeo, Sin Yuin; Elevelt, Aaldert; Donato, Katia; van Rietbergen, Bert; ter Hoeve, Natalie D.; van Diest, Paul J.; Grüll, Holger

    2015-01-01

    Objectives: Bone pain resulting from cancer metastases reduces a patient's quality of life. Magnetic Resonance-guided High Intensity Focused Ultrasound (MR-HIFU) is a promising alternative palliative thermal treatment technique for bone metastases that has been tested in a few clinical studies. Here

  5. Creatine supplementation spares muscle glycogen during high intensity intermittent exercise in rats

    Directory of Open Access Journals (Sweden)

    Costa André

    2010-01-01

    Full Text Available Abstract Background The effects of creatine (CR supplementation on glycogen content are still debatable. Thus, due to the current lack of clarity, we investigated the effects of CR supplementation on muscle glycogen content after high intensity intermittent exercise in rats. Methods First, the animals were submitted to a high intensity intermittent maximal swimming exercise protocol to ensure that CR-supplementation was able to delay fatigue (experiment 1. Then, the CR-mediated glycogen sparing effect was examined using a high intensity intermittent sub-maximal exercise test (fixed number of bouts; six bouts of 30-second duration interspersed by two-minute rest interval (experiment 2. For both experiments, male Wistar rats were given either CR supplementation or placebo (Pl for 5 days. Results As expected, CR-supplemented animals were able to exercise for a significant higher number of bouts than Pl. Experiment 2 revealed a higher gastrocnemius glycogen content for the CR vs. the Pl group (33.59%. Additionally, CR animals presented lower blood lactate concentrations throughout the intermittent exercise bouts compared to Pl. No difference was found between groups in soleus glycogen content. Conclusion The major finding of this study is that CR supplementation was able to spare muscle glycogen during a high intensity intermittent exercise in rats.

  6. Productions of hollow atoms from solids irradiated by high intensity laser

    Energy Technology Data Exchange (ETDEWEB)

    Moribayashi, K.; Sasaki, A.; Zhidkov, A. [Advanced Photon Research Center, Kansai Research Establishment, Japan Atomic Energy Research Inst. (Japan)

    2001-07-01

    The production of hollow atoms through the collisions of fast electrons with a solid is studied. These electrons are produced by high-intensity short-pulse laser irradiation on a solid. The inner-shell ionization and excitation processes by the fast electron impact are investigated. It is found that ionization processes give more significant contribution to the production of hollow atoms. (orig.)

  7. Status of High Intensity Polarized Electron Gun at Mit-Bates

    Science.gov (United States)

    Tsentalovich, E.; Bessuille, J.; Tiunov, M.

    2011-01-01

    MIT-Bates, in collaboration with BNL, has developed a high intensity polarized electron gun for the eRHIC project. The gun implements large area cathode, ring-shaped beam and active cathode cooling. The paper describes the current status of the project.

  8. The Edward Teller Medal Lecture: High Intensity Lasers and the Road to Ignition (lirpp Vol. 13)

    Science.gov (United States)

    Key, M. H.

    2016-10-01

    There has been much progress in the development of high intensity lasers and in the science of laser driven inertially confined fusion such that ignition is now a near term prospect. This lecture reviews the field with particular emphasis on areas of my own involvement.

  9. MRI-guided High-Intensity Focused Ultrasound of Breast Cancer

    NARCIS (Netherlands)

    Merckel, L.G.

    2014-01-01

    Magnetic resonance imaging-guided high-intensity focused ultrasound (MR-HIFU) is a promising technique for completely noninvasive tumor ablation. This thesis focuses on its application for the treatment of patients with breast cancer. The first part of the thesis describes the role of breast MRI for

  10. High-level fusion of depth and intensity for pedestrian classification

    NARCIS (Netherlands)

    Rohrbach, M.; Enzweiler, M.; Gavrila, D.M.

    2009-01-01

    This paper presents a novel approach to pedestrian classification which involves a high-level fusion of depth and intensity cues. Instead of utilizing depth information only in a pre-processing step, we propose to extract discriminative spatial features (gradient orientation histograms and local

  11. Postexercise cold-water immersion improves intermittent high-intensity exercise performance in normothermia.

    Science.gov (United States)

    McCarthy, Avina; Mulligan, James; Egaña, Mikel

    2016-11-01

    A brief cold water immersion between 2 continuous high-intensity exercise bouts improves the performance of the latter compared with passive recovery in the heat. We investigated if this effect is apparent in normothermic conditions (∼19 °C), employing an intermittent high-intensity exercise designed to reflect the work performed at the high-intensity domain in team sports. Fifteen young active men completed 2 exhaustive cycling protocols (Ex1 and Ex2: 12 min at 85% ventilatory threshold (VT) and then an intermittent exercise alternating 30-s at 40% peak power (Ppeak) and 30 s at 90% Ppeak to exhaustion) separated by 15 min of (i) passive rest, (ii) 5-min cold-water immersion at 8 °C, and (iii) 10-min cold-water immersion at 8 °C. Core temperature, heart rate, rates of perceived exertion, and oxygen uptake kinetics were not different during Ex1 among conditions. Time to failure during the intermittent exercise was significantly (P intermittent high-intensity exercise compared with passive rest in normothermia due, at least in part, to reductions in core temperature, circulatory strain, and effort perception.

  12. Effects of 12 weeks high-intensity & reduced-volume training in elite athletes

    DEFF Research Database (Denmark)

    Kilen, Anders; Larsson, Tanja Hultengren; Jørgensen, Majke;

    2014-01-01

    It was investigated if high-intensity interval training (HIT) at the expense of total training volume improves performance, maximal oxygen uptake and swimming economy. 41 elite swimmers were randomly allocated to a control (CON) or HIT group. For 12 weeks both groups trained ∼12 h per week. HIT c...

  13. Responses of Plasma Atrial Natriuretic Peptide to High Intensity Submaximal Exercise in the Heat,

    Science.gov (United States)

    1987-06-01

    Natriuretic Peptide to LnHigh Intensity Submaximal Exercise in the Heat 0 " William J. Kraemer. Lawrence E. Armstrong, Roger W. Hubbard. :I[_] Louis J...atriopeptins in rat adrenal cells. Cir Res 57: 113-118. f V-0C -- V- - IF -I 7 - % 7 -. 17 Chartier L. Schiffrin EL. Thibault G (1984). Effects of atrial

  14. Ionization and acceleration of heavy ions in high-Z solid target irradiated by high intensity laser

    OpenAIRE

    Kawahito, D.; Kishimoto, Y

    2016-01-01

    In the interaction between high intensity laser and solid film, an ionization dynamics inside the solid is dominated by fast time scale convective propagation of the internal sheath field and the slow one by impact ionization due to heated high energy electrons coupled with nonlocal heat transport. Furthermore, ionization and acceleration due to the localized external sheath field which co- propagates with Al ions constituting the high energy front in the vacuum region. Through this process, ...

  15. New technologies in lighting systems for high-speed film and photography regarding high-intensity and heat problems

    Science.gov (United States)

    Severon, Burkhard

    1991-04-01

    Increasing frame rates and the heat sensibility of test objects forced the development of new lighting systems. For example at the automotive industry, where continuous light sources are indispensable for the high speed photography of car crash tests and automobile components tests, the further development of high efficient safety systems, so as Air-Bag systems, needs very datailed analysis of the accelerated motions. Frame rates from 2.000 up to 10.000 frames per second are requested and beside adequate camera systems and film material, this also means high intensive lighting systems. The need for high intensity could be easy achieved by the use of additional light fixtures but the request for more intensity comes along with the problem of heat. The test objects and the auxiliary materials become more and more temperature- sensitive. Very offen they have to be used under strict climate conditions. Mainly there where the test objects are already placed inside the illuminated area, the heat radiation of the light sources to the test objects have to be reduced. So high intensive, flicker free and less heat are today's requirements of light performance. This paper will present solutions to meet those demands.

  16. High harmonic generation from bulk diamond driven by intense femtosecond laser pulse

    CERN Document Server

    Apostolova, Tzveta

    2016-01-01

    We investigate the high-harmonic generation (HHG) from bulk diamond induced by intense 15 fs laser pulse and photon energy 1.55 eV. For laser intensity in the range $I \\in [1,50]$ TW/cm$^2$, we find that HHG spectra from diamond exhibits two plateaus with high harmonics extending beyond the 50th order. Consistently with experimental observations, we find that the cutoff energy of the two plateaus scales linearly with the field strength. The first plateau is due to recombination of electron-hole pairs near the Brillouin zone center. The appearance of weak second plateau region for high field strength with $F \\sim$ 1 V/$\\AA$ results in emission of highly energetic XUV photons.

  17. Recovery of a soil under different vegetation one year after a high intensity wildfire

    Directory of Open Access Journals (Sweden)

    A. Martín

    2013-05-01

    Full Text Available Studies on soil recovery in fragile ecosystems following high intensity wildfires are scarce. The aim of the present investigation is to evaluate the impact of a high intensity wildfire in an ecosystem under different vegetation (shrubland and pinewood located at Vilardevós (Galicia, NW Spain and highly susceptible to suffer soil erosion due to the steep relief and high erositivity of the rainfall. Soil samples were collected from the A horizon (0-5 cm 1 year after the fire and soil quality was evaluated by analysis of several physical, chemical and biochemical properties measured in the fraction chemical properties > physical properties. The data also showed that the fire impact was different depending on the soil vegetation considered (shrubland and pinewood. Moreover, the data confirmed the slow soil recovery in this fragile ecosystem and, therefore, the need of adopting post-fire stabilisation and rehabilitation treatments in order to minimize the post-fire erosion and soil degradation.

  18. High-Resolution Energy and Intensity Measurements with CVD Diamond at REX-ISOLDE

    CERN Document Server

    Griesmayer, E; Dobos, D; Wenander, F; Bergoz, J; Bayle, H; Frais-Kölbl, H; Leinweber, J; Aumeyr, T; CERN. Geneva. BE Department

    2009-01-01

    A novel beam instrumentation device for the HIE-REX (High In-tensity and Energy REX) upgrade has been developed and tested at the On-Line Isotope Mass Separator ISOLDE, located at the European Laboratory for Particle Physics (CERN). This device is based on CVD diamond detector technology and is used for measuring the beam intensity, particle counting and measuring the energy spectrum of the beam. An energy resolution of 0.6% was measured at a carbon ion energy of 22.8 MeV. This corresponds to an energy spread of ± 140 keV.

  19. Start-to-end simulations for the proposed Fermilab high intensity proton source

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Jean-Paul; Johnson, D.E.; Webber, R.C.; /Fermilab

    2007-06-01

    A High Intensity Proton Source consisting in an 8 GeV superconducting H-minus linac and transfer line to the Main Injector has been proposed. The primary mission is to increase the intensity of the Fermilab Main Injector for the production of neutrino superbeams. Start-to-end simulations from the RFQ to the stripping foil using the simulation code TRACK (ANL) is presented in this paper. In particular, we will study the impact of jitter errors on the H-minus phase space at the stripping foil.

  20. High-Energy Ions Emitted from Ar Clusters Irradiated by Intense Femtosecond Laser Pulses

    Institute of Scientific and Technical Information of China (English)

    LI Zhong; LEI An-Le; NI Guo-Quan; XU Zhi-Zhan

    2000-01-01

    We have experimentally studied the energy spectra of Ar ions emitted from Ar clusters irradiated by intense femtosecond laser pulses. The Ar clusters were produced in the adiabatic expansion of Ar gas into vacuum at high backing pressures. The laser peak intensity was about 2×106 W/cm2 with a pulse duration of 45 fs. The maximum and the average energies of Ar ions are 0.2 MeV and 15kev at a backing pressure of 2. S MPa, respectively. They are almost independent of the backing pressures in the range of 0.6 to 4.5 MPa.

  1. Salutary effects of high-intensity interval training in persons with elevated cardiovascular risk.

    Science.gov (United States)

    Fleg, Jerome L

    2016-01-01

    Although moderate-intensity continuous training (MICT) has been the traditional model for aerobic exercise training for over four decades, a growing body of literature has demonstrated equal if not greater improvement in aerobic capacity and similar beneficial effects on body composition, glucose metabolism, blood pressure, and quality of life from high-intensity interval training (HIIT). An advantage of HIIT over MICT is the shorter time required to perform the same amount of energy expenditure. The current brief review summarizes the effects of HIIT on peak aerobic capacity and cardiovascular risk factors in healthy adults and those with various cardiovascular diseases, including coronary artery disease, chronic heart failure, and post heart transplantation.

  2. Acute Effect of High-Intensity Eccentric Exercise on Vascular Endothelial Function in Young Men.

    Science.gov (United States)

    Choi, Youngju; Akazawa, Nobuhiko; Zempo-Miyaki, Asako; Ra, Song-Gyu; Shiraki, Hitoshi; Ajisaka, Ryuichi; Maeda, Seiji

    2016-08-01

    Choi, Y, Akazawa, N, Zempo-Miyaki, A, Ra, S-G, Shiraki, H, Ajisaka, R, and Maeda, S. Acute effect of high-intensity eccentric exercise on vascular endothelial function in young men. J Strength Cond Res 30(8): 2279-2285, 2016-Increased central arterial stiffness is as an independent risk factor for cardiovascular disease. Evidence regarding the effects of high-intensity resistance exercise on vascular endothelial function and central arterial stiffness is conflicting. The purpose of this study was to examine the effects of acute high-intensity eccentric exercise on vascular endothelial function and central arterial stiffness. We evaluated the acute changes in endothelium-dependent flow-mediated dilation (FMD), low-flow-mediated constriction (L-FMC), and arterial stiffness after high-intensity eccentric exercise. Seven healthy, sedentary men (age, 24 ± 1 year) performed maximal eccentric elbow flexor exercise using their nondominant arm. Before and 45 minutes after eccentric exercise, carotid arterial compliance and brachial artery FMD and L-FMC in the nonexercised arm were measured. Carotid arterial compliance was significantly decreased, and β-stiffness index significantly increased after eccentric exercise. Brachial FMD was significantly reduced after eccentric exercise, whereas there was no significant difference in brachial L-FMC before and after eccentric exercise. A positive correlation was detected between change in arterial compliance and change in FMD (r = 0.779; p ≤ 0.05), and a negative correlation was detected between change in β-stiffness index and change in FMD (r = -0.891; p eccentric exercise. In this study, acute high-intensity eccentric exercise increased central arterial stiffness; this increase was accompanied by a decrease in endothelial function caused by reduced endothelium-dependent vasodilation but not by a change in endothelium-dependent vasoconstriction.

  3. Psychophysiological effects of music on acute recovery from high-intensity interval training.

    Science.gov (United States)

    Jones, Leighton; Tiller, Nicholas B; Karageorghis, Costas I

    2017-03-01

    Numerous studies have examined the multifarious effects of music applied during exercise but few have assessed the efficacy of music as an aid to recovery. Music might facilitate physiological recovery via the entrainment of respiratory rhythms with music tempo. High-intensity exercise training is not typically associated with positive affective responses, and thus ways of assuaging negative affect warrant further exploration. This study assessed the psychophysiological effects of music on acute recovery and prevalence of entrainment in between bouts of high-intensity exercise. Thirteen male runners (Mage=20.2±1.9years; BMI=21.7±1.7; V̇O2 max=61.6±6.1mL·kg·min(-1)) completed three exercise sessions comprising 5×5-min bouts of high-intensity intervals interspersed with 3-min periods of passive recovery. During recovery, participants were administered positively-valenced music of a slow-tempo (55-65bpm), fast-tempo (125-135bpm), or a no-music control. A range of measures including affective responses, RPE, cardiorespiratory indices (gas exchange and pulmonary ventilation), and music tempo-respiratory entrainment were recorded during exercise and recovery. Fast-tempo, positively-valenced music resulted in higher Feeling Scale scores throughout recovery periods (p<0.01, ηp(2)=0.38). There were significant differences in HR during initial recovery periods (p<0.05, ηp(2)=0.16), but no other music-moderated differences in cardiorespiratory responses. In conclusion, fast-tempo, positively-valenced music applied during recovery periods engenders a more pleasant experience. However, there is limited evidence that music expedites cardiorespiratory recovery in between bouts of high-intensity exercise. These findings have implications for athletic training strategies and individuals seeking to make high-intensity exercise sessions more pleasant.

  4. Intensive lifestyle intervention including high-intensity interval training program improves insulin resistance and fasting plasma glucose in obese patients

    Directory of Open Access Journals (Sweden)

    Guillaume Marquis-Gravel

    2015-01-01

    Conclusion: Following a 9-month intensive lifestyle intervention combining HIIT and MedD counseling, obese subjects experienced significant improvements of FPG and insulin resistance. This is the first study to expose the effects of a long-term program combining HIIT and MedD on glycemic control parameters among obese subjects.

  5. Using high-fidelity simulation as a learning strategy in an undergraduate intensive care course.

    Science.gov (United States)

    Badir, Aysel; Zeybekoğlu, Zuhal; Karacay, Pelin; Göktepe, Nilgün; Topcu, Serpil; Yalcin, Begüm; Kebapci, Ayda; Oban, Gül

    2015-01-01

    Using high-fidelity simulations to facilitate student learning is an uncommon practice in Turkish nursing programs. The aim of the present study was to understand students' perceptions of the use of simulation in nursing courses. Subjects included 36 senior nursing students taking an intensive care course. This study revealed that high-fidelity simulation is an ideal method of promoting learning by helping students transfer theory into practice, build confidence and teamwork, and raise professional awareness.

  6. Personalized Metabolomics for Predicting Glucose Tolerance Changes in Sedentary Women After High-Intensity Interval Training

    OpenAIRE

    Kuehnbaum, Naomi L.; Gillen, Jenna B.; Gibala, Martin J.; Britz-McKibbin, Philip

    2014-01-01

    High-intensity interval training (HIIT) offers a practical approach for enhancing cardiorespiratory fitness, however its role in improving glucose regulation among sedentary yet normoglycemic women remains unclear. Herein, multi-segment injection capillary electrophoresis-mass spectrometry is used as a high-throughput platform in metabolomics to assess dynamic responses of overweight/obese women (BMI > 25, n = 11) to standardized oral glucose tolerance tests (OGTTs) performed before and after...

  7. Report from the NSLS workshop: Sources and applications of high intensity uv-vuv light

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.D.; Hastings, J.B. [eds.

    1990-12-31

    A workshop was held to evaluate sources and applications of high intensity, ultra violet (UV) radiation for biological, chemical, and materials sciences. The proposed sources are a UV free electron laser (FEL) driven by a high brightness linac and undulators in long, straight sections of a specially designed low energy (400 MeV) storage ring. These two distinct types of sources will provide a broad range of scientific opportunities that were discussed in detail during the workshop.

  8. Report from the NSLS workshop: Sources and applications of high intensity uv-vuv light

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, E.D.; Hastings, J.B. (eds.)

    1990-01-01

    A workshop was held to evaluate sources and applications of high intensity, ultra violet (UV) radiation for biological, chemical, and materials sciences. The proposed sources are a UV free electron laser (FEL) driven by a high brightness linac and undulators in long, straight sections of a specially designed low energy (400 MeV) storage ring. These two distinct types of sources will provide a broad range of scientific opportunities that were discussed in detail during the workshop.

  9. Repeated high-intensity running and sprinting in elite women’s soccer competition

    OpenAIRE

    Gabbett, Tim J; Wiig, Håvard; Spencer, Matt

    2013-01-01

    Background: To the authors’ knowledge, no study has investigated the concurrent repeated, high-intensity (RHIA) and repeated-sprint activity (RSA) of intermittent team-sport competition. Purpose: In this study, they report on the RSA of elite women’s football competition. In addition, they describe the nature of RHIA (eg, striding and sprinting activities) that involve a high energy cost and are associated with short (ie, ≤20 s) recovery periods. Methods: Thirteen elite women soccer players u...

  10. Tune measurements with high intensity ion beams at GSI SIS-18

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Rahul [GSI, Darmstadt (Germany); TEMF, TU Darmstadt (Germany); Forck, Peter; Kowina, Piotr; Kaufmann, Wolfgang [GSI, Darmstadt (Germany); Weiland, Thomas [TEMF, TU Darmstadt (Germany)

    2012-07-01

    A precise tune measurement during a full accelerating cycle is required to achieve stable high current operation. A new system has been commissioned at GSI for position, orbit and tune measurements. It consists of three distinct parts; an exciter which provides power to excite coherent betatron oscillations in the bunched beam; Fast ADCs to digitize the BPM signals at 125 MSa/s; the post processing electronics uses digitized BPM signals to acquire one position value per bunch. Subsequently the baseband tune is determined by Fourier transformation of the position data. Experiments were conducted to understand the effects of high beam intensity on tune at injection plateau (11.4 MeV/u) and during acceleration ramp (11.4-600 MeV/u). These experiments were performed with U{sup 73+} and Ar{sup 18+} ion beam at highest achievable intensities of 2.10{sup 9} and 2.5.10{sup 10} respectively. Tune shift with increased intensity was observed. The working principle of the tune measurement system and observed high intensity effects on tune will be reported in this contribution.

  11. The effects of light emitting diode therapy following high intensity exercise.

    Science.gov (United States)

    Denis, Romain; O'Brien, Christopher; Delahunt, Eamonn

    2013-05-01

    To determine the effects of light emitting diode therapy (LEDT) irradiation on blood lactate concentration ([La]) clearance, peak power output and fatigue index (FI) following high intensity fatiguing exercise. Single-blinded randomised cross-over placebo controlled trial. University College Dublin, Institute for Sport and Health, Human performance laboratory. Eighteen healthy male athletes were recruited from field-based sports (including soccer, hockey and rugby union) and participated in the present study. Dependent variables were the peak power output elicited during the Wingate Anaerobic Test (WAnT), FI and [La] before and after each exercise. WAnT performance was measured prior to high intensity fatiguing exercise (Yo-Yo IR2), prior to LEDT or placebo, and following LEDT or placebo. [La] was measured at baseline, immediately after the Yo-Yo IR2, and in the 3rd, 9th, and 15th min following LEDT or placebo condition. No significant group by treatment interactions were observed for any outcome measures (P > 0.05). We conclude that LEDT irradiation applied following high intensity exercise was not effective and has no immediate effect on [La] clearance, peak power and FI, and thus has no significant effect on muscle recovery in athletes at the intensity and irradiation parameters used in the present study. Further research using different parameters is required to determine how LEDT may contribute to post-exercise recovery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Joint Cooling does not Hinder Athletic Performance during High-intensity Intermittent Exercise.

    Science.gov (United States)

    Kim, H; Lee, D; Choi, H-M; Park, J

    2016-07-01

    We examined the effects of ankle and knee joint cooling on 20-m sprint times and maximal vertical jump heights during high-intensity intermittent exercise. 21 healthy collegiate male basketball (n=14) and handball players (n=7) underwent 3 experimental sessions. Each session consisted of four 15-min quarters of high-intensity intermittent exercises including various intensities of 20-m shuttle running and jumping. A 20-min bilateral joint cooling (ankle, knee, or control-no cooling: in a counterbalanced order) was applied before quarters 1 and 3. After joint cooling, no warm-up activity other than the exercise protocol was given. The 20-m sprint times and maximal vertical jump heights in each experimental session were recorded at baseline (prior to quarter-1) and during each quarter. To test joint cooling effects over time, we performed 3×5 mixed model ANOVAs. Neither ankle nor knee joint cooling changed 20-m sprint times (F8,280=1.45; p=0.18) or maximal vertical jump heights (F8,280=0.76; p=0.64). However, a trend was observed in which joint cooling immediately decreased (quarters 1 and 3) but active warm-up for approximately 20 min improved 20-min sprint times (quarters 2 and 4). Our study suggests that athletic performance such as sprinting and jumping are not altered by joint cooling applied prior to or during high-intensity intermittent exercise.

  13. An FEL based high-intensity gamma source at the TESLA Test Facility at DESY

    CERN Document Server

    Pagani, C; Schneidmiller, E A; Yurkov, M V

    1999-01-01

    One possible extension of the FEL activity at DESY is connected with the installation of an additional FEL beamline providing tunable UV radiation with peak and average power of 220 GW and 7 kW, respectively. This report presents the feasibility study of a high-intensity, polarized, monochromatic gamma source at the TESLA Test Facility. Gamma quanta are produced in the process of Compton backscattering of the UV FEL radiation on 1 GeV electrons of the TTF accelerator. The ultimate intensity of the gamma source can reach a value up to 10 sup 1 sup 2 gamma quanta per second with a maximum energy of about 100 MeV. The energy resolution of the gamma source can be reduced down to a value of about 0.2%. Potential applications of the intense gamma source at the TESLA Test Facility are discussed as well.

  14. Narrowband inverse Compton scattering x-ray sources at high laser intensities

    CERN Document Server

    Seipt, D; Surzhykov, A; Fritzsche, S

    2014-01-01

    Narrowband x- and gamma-ray sources based on the inverse Compton scattering of laser pulses suffer from a limitation of the allowed laser intensity due to the onset of nonlinear effects that increase their bandwidth. It has been suggested that laser pulses with a suitable frequency modulation could compensate this ponderomotive broadening and reduce the bandwidth of the spectral lines, which would allow to operate narrowband Compton sources in the high-intensity regime. In this paper we, therefore, present the theory of nonlinear Compton scattering in a frequency modulated intense laser pulse. We systematically derive the optimal frequency modulation of the laser pulse from the scattering matrix element of nonlinear Compton scattering, taking into account the electron spin and recoil. We show that, for some particular scattering angle, an optimized frequency modulation completely cancels the ponderomotive broadening for all harmonics of the backscattered light. We also explore how sensitive this compensation ...

  15. A Mechanism Underlying Preventive Effect of High-Intensity Training on Colon Cancer.

    Science.gov (United States)

    Matsuo, Kaori; Sato, Koji; Suemoto, Ken; Miyamoto-Mikami, Eri; Fuku, Noriyuki; Higashida, Kazuhiko; Tsuji, Katsunori; Xu, Yuzhong; Liu, Xin; Iemitsu, Motoyuki; Hamaoka, Takafumi; Tabata, Izumi

    2017-09-01

    We examined effects of high-intensity training on chemically induced aberrant crypt foci (ACF) in rat colon. We also investigated mechanisms that may underlie the results obtained, with a focus on secreted protein acidic and rich in cysteine (SPARC), which has been proposed as an exercise-related factor of colon cancer prevention. After an administration of 1,2-dimethylhydrazine, F344 rats executed high-intensity intermittent swimming training (HIIST) (twelve 20-s swimming with a weight [16% body weight] with 10-s pauses between the bouts) 5 d·wk for 4 wk. The acute and chronic effects of the HIIST on SPARC were evaluated in rats. We evaluated the in vitro and in vivo effects of 5' AMP-activated protein kinase (AMPK) activator on SPARC in rat serum and epitrochlearis muscle. In human subjects, we determined serum SPARC after exhaustive bicycling consisting of six to seven bouts of exercise at 170% V˙O2max with 10-s rests between the bouts (high-intensity intermittent bicycling [HIIB]). The SPARC mRNA in human vastus lateralis was measured before and after the HIIB for 4 d·wk for 6 wk (HIIB-training [HIIBT]). The numbers of ACF were lower in the HIIST (47 ± 22) compared with the control (122 ± 47) rats (P < 0.05). SPARC in epitrochlearis and serum after HIIS of the trained rat was higher than that in the control resting rats. In vitro and vivo AMPK stimulation increased mRNA and SPARC protein in rat epitrochlearis, respectively. The human serum SPARC after the HIIB was elevated. SPARC mRNA in human muscle was elevated after the HIIBT. The results demonstrated that HIIST inhibits 1,2-dimethylhydrazine-induced colon ACF development. This effect may be explained by SPARC induction by the exercise intensity-related factor AMPK, potentially explaining the preventive effects of high-intensity intermittent exercise training against colon cancer.

  16. Student Engagement, School Climate, and Future Expectations in High School.

    Science.gov (United States)

    Hudley, Cynthia; Daoud, Annette; Polanco, Ted; Wright-Castro, Rosina; Hershberg, Rachel

    Engagement is a potentially useful construct for organizing strategies to support adjustment, achievement and retention in school, particularly among our most vulnerable student populations. Even if high quality schooling is available, high levels of achievement will implicitly demand engagement on the part of students. This initial analysis,…

  17. Development of low-volume, high-intensity, aerobic-type interval training for elderly Japanese men: a feasibility study.

    Science.gov (United States)

    Osuka, Yosuke; Matsubara, Muneaki; Hamasaki, Ai; Hiramatsu, Yuji; Ohshima, Hiroshi; Tanaka, Kiyoji

    2017-01-01

    The purposes of this study were to identify 1) the feasibility of a novel exercise protocol (elderly Japanese male version of high-intensity interval aerobic training: EJ-HIAT) and 2) its preliminary data (%V̇O2peak, rating of perceived exertion) in comparison with traditional moderate-intensity continuous aerobic training (MICT). Twenty-one sedentary elderly men, aged 60-69 years, performed two exercise protocols: EJ-HIAT, consisting of 3 sets of 2-3-min cycling at 75-85%V̇O2peak with 1-2-min active rests at 50%V̇O2peak between sets, and MICT, consisting of 40-min cycling at 65%V̇O2peak. The completion rate, defined as the rate of participants who 1) did not demand withdrawal, 2) were not interrupted by the tester, and 3) did not change the workload during either exercise protocol, of EJ-HIAT was similar to that of MICT (EJ-HIAT: 100%, MICT: 95.2%). Maximal perceived exertion ratings assessed by Borg scale were also similar between EJ-HIAT and MICT. However, objectively measured maximal intensity assessed by %V̇O2peak was higher for EJ-HIAT than for MICT (EJ-HIAT: 86.0 ± 5.6%, MICT: 67.1 ± 6.4%). These results suggested that EJ-HIAT has good feasibility and perceived exertion similar to MICT despite having higher objectively measured intensity than MICT. An intervention aimed as identifying the effects of EJ-HIAT on exercise tolerance should be performed in the future. UMIN000021185 (February 26, 2016).

  18. Pulsed x-ray imaging of high-density objects using a ten picosecond high-intensity laser driver

    Science.gov (United States)

    Rusby, D. R.; Brenner, C. M.; Armstrong, C.; Wilson, L. A.; Clarke, R.; Alejo, A.; Ahmed, H.; Butler, N. M. H.; Haddock, D.; Higginson, A.; McClymont, A.; Mirfayzi, S. R.; Murphy, C.; Notley, M.; Oliver, P.; Allott, R.; Hernandez-Gomez, C.; Kar, S.; McKenna, P.; Neely, D.

    2016-10-01

    Point-like sources of X-rays that are pulsed (sub nanosecond), high energy (up to several MeV) and bright are very promising for industrial and security applications where imaging through large and dense objects is required. Highly penetrating X-rays can be produced by electrons that have been accelerated by a high intensity laser pulse incident onto a thin solid target. We have used a pulse length of 10ps to accelerate electrons to create a bright x-ray source. The bremsstrahlung temperature was measured for a laser intensity from 8.5-12×1018 W/cm2. These x-rays have sequentially been used to image high density materials using image plate and a pixelated scintillator system.

  19. Optimisation extraction of chondroitin sulfate from fish bone by high intensity pulsed electric fields.

    Science.gov (United States)

    He, Guidan; Yin, Yongguang; Yan, Xiaoxia; Yu, Qingyu

    2014-12-01

    High intensity pulsed electric fields (PEF) was used to extract chondroitin sulphate (CS) from fish bone. Results show that PEF extraction speed is much faster, and the content of CS is much higher compared with traditional methods. Variation of PEF parameters and the content of CS were determined by single factor experiments. The processing conditions were optimised by quadratic general rotary unitised design experiments. The maximum yield of 6.92 g/L was achieved under the following conditions: material-liquid ratio of 1:15 g/mL, electric field intensity of 16.88 kV/cm, pulse number of 9, and NaOH concentration of 3.24%. The purity of CS was analysed by agarose gel electrophoresis. CS purity was high, and the extract did not contain any other glycosaminoglycans. PEF can be widely used to extract CS with non-thermal performance, high speed, and low pollution.

  20. MIMO Intensity-Modulation Channels: Capacity Bounds and High SNR Characterization

    KAUST Repository

    Chaaban, Anas

    2016-10-01

    The capacity of MIMO intensity modulation channels is studied. The nonnegativity of the transmit signal (intensity) poses a challenge on the precoding of the transmit signal, which limits the applicability of classical schemes in this type of channels. To resolve this issue, capacity lower bounds are developed by using precoding-free schemes. This is achieved by channel inversion or QR decomposition to convert the MIMO channel to a set of parallel channels. The achievable rate of a DC-offset SVD based scheme is also derived as a benchmark. Then, a capacity upper bound is derived and is shown to coincide with the achievable rate of the QR decomposition based scheme at high SNR, consequently characterizing the high-SNR capacity of the channel. The high-SNR gap between capacity and the achievable rates of the channel inversion and the DC-offset SVD based schemes is also characterized. Finally, the ergodic capacity of the channel is also briefly discussed.

  1. Beam Dynamics Studies for High-Intensity Beams in the CERN Proton Synchrotron

    CERN Document Server

    AUTHOR|(CDS)2082016; Benedikt, Michael

    With the discovery of the Higgs boson, the existence of the last missing piece of the Standard Model of particle physics (SM) was confirmed. However, even though very elegant, this theory is unable to explain, for example, the generation of neutrino masses, nor does it account for dark energy or dark matter. To shed light on some of these open questions, research in fundamental particle physics pursues two complimentary approaches. On the one hand, particle colliders working at the high-energy frontier, such as the Large Hadron Collider (LHC) at the European Organization for Nuclear Research (CERN), located in Geneva, Switzerland, are utilized to investigate the fundamental laws of nature. Alternatively, fixed target facilities require high-intensity beams to create a large flux of secondary particles to investigate, for example, rare particle decay processes, or to create neutrino beams. This thesis investigates limitations arising during the acceleration of high-intensity beams at the CERN Proton Synchrotro...

  2. High Intensity Laser Power Beaming Architecture for Space and Terrestrial Missions

    Science.gov (United States)

    Nayfeh, Taysir; Fast, Brian; Raible, Daniel; Dinca, Dragos; Tollis, Nick; Jalics, Andrew

    2011-01-01

    High Intensity Laser Power Beaming (HILPB) has been developed as a technique to achieve Wireless Power Transmission (WPT) for both space and terrestrial applications. In this paper, the system architecture and hardware results for a terrestrial application of HILPB are presented. These results demonstrate continuous conversion of high intensity optical energy at near-IR wavelengths directly to electrical energy at output power levels as high as 6.24 W from the single cell 0.8 cm2 aperture receiver. These results are scalable, and may be realized by implementing receiver arraying and utilizing higher power source lasers. This type of system would enable long range optical refueling of electric platforms, such as MUAV s, airships, robotic exploration missions and provide power to spacecraft platforms which may utilize it to drive electric means of propulsion.

  3. Measurement and interpretation of threshold stress intensity factors for steels in high-pressure hydrogen gas.

    Energy Technology Data Exchange (ETDEWEB)

    Dadfarnia, Mohsen (University of Illinois at Urbana-Champaign, Urbana, IL); Nibur, Kevin A.; San Marchi, Christopher W.; Sofronis, Petros (University of Illinois at Urbana-Champaign, Urbana, IL); Somerday, Brian P.; Foulk, James W., III; Hayden, Gary A. (CP Industries, McKeesport, PA)

    2010-07-01

    Threshold stress intensity factors were measured in high-pressure hydrogen gas for a variety of low alloy ferritic steels using both constant crack opening displacement and rising crack opening displacement procedures. The sustained load cracking procedures are generally consistent with those in ASME Article KD-10 of Section VIII Division 3 of the Boiler and Pressure Vessel Code, which was recently published to guide design of high-pressure hydrogen vessels. Three definitions of threshold were established for the two test methods: K{sub THi}* is the maximum applied stress intensity factor for which no crack extension was observed under constant displacement; K{sub THa} is the stress intensity factor at the arrest position for a crack that extended under constant displacement; and K{sub JH} is the stress intensity factor at the onset of crack extension under rising displacement. The apparent crack initiation threshold under constant displacement, K{sub THi}*, and the crack arrest threshold, K{sub THa}, were both found to be non-conservative due to the hydrogen exposure and crack-tip deformation histories associated with typical procedures for sustained-load cracking tests under constant displacement. In contrast, K{sub JH}, which is measured under concurrent rising displacement and hydrogen gas exposure, provides a more conservative hydrogen-assisted fracture threshold that is relevant to structural components in which sub-critical crack extension is driven by internal hydrogen gas pressure.

  4. High-intensity exercise training for the prevention of type 2 diabetes mellitus.

    Science.gov (United States)

    Rynders, Corey A; Weltman, Arthur

    2014-02-01

    Aerobic exercise training and diet are recommended for the primary prevention of type 2 diabetes mellitus and cardiovascular disease. The American Diabetes Association (ADA) recommends that adults with prediabetes engage in ≥ 150 minutes per week of moderate activity and target a 7% weight loss. However, traditional moderate-intensity (MI) exercise training programs are often difficult to sustain for prediabetic adults; a commonly cited barrier to physical activity in this population is the "lack of time" to exercise. When matched for total energy expenditure, high-intensity (HI) exercise training has a lower overall time commitment compared with traditional low-intensity (LI) or MI exercise training. Several recent studies comparing HI exercise training with LI and MI exercise training reported that HI exercise training improves skeletal muscle metabolic control and cardiovascular function in a comparable and/or superior way relative to LI and MI exercise training. Although patients can accrue all exercise benefits by performing LI or MI activities such as walking, HI activities represent a time-efficient alternative to meeting physical activity guidelines. High-intensity exercise training is a potent tool for improving cardiometabolic risk for prediabetic patients with limited time and may be prescribed when appropriate.

  5. High-intensity interval training has positive effects on performance in ice hockey players.

    Science.gov (United States)

    Naimo, M A; de Souza, E O; Wilson, J M; Carpenter, A L; Gilchrist, P; Lowery, R P; Averbuch, B; White, T M; Joy, J

    2015-01-01

    In spite of the well-known benefits that have been shown, few studies have looked at the practical applications of high-intensity interval training (HIIT) on athletic performance. This study investigated the effects of a HIIT program compared to traditional continuous endurance exercise training. 24 hockey players were randomly assigned to either a continuous or high-intensity interval group during a 4-week training program. The interval group (IG) was involved in a periodized HIIT program. The continuous group (CG) performed moderate intensity cycling for 45-60 min at an intensity that was 65% of their calculated heart rate reserve. Body composition, muscle thickness, anaerobic power, and on-ice measures were assessed pre- and post-training. Muscle thickness was significantly greater in IG (p=0.01) when compared to CG. The IG had greater values for both ∆ peak power (p<0.003) and ∆ mean power (p<0.02). Additionally, IG demonstrated a faster ∆ sprint (p<0.02) and a trend (p=0.08) for faster ∆ endurance test time to completion for IG. These results indicate that hockey players may utilize short-term HIIT to elicit positive effects in muscle thickness, power and on-ice performance.

  6. Influence of carbohydrate supplementation on plasma cytokine and neutrophil degranulation responses to high intensity intermittent exercise.

    Science.gov (United States)

    Bishop, Nicolette C; Gleeson, Michael; Nicholas, Ceri W; Ali, Ajmol

    2002-06-01

    Ingesting carbohydrate (CHO) beverages during prolonged, continuous heavy exercise results in smaller changes in the plasma concentrations of several cytokines and attenuates a decline in neutrophil function. In contrast, ingesting CHO during prolonged intermittent exercise appears to have negligible influence on these responses, probably due to the overall moderate intensity of these intermittent exercise protocols. Therefore, we examine the effect of CHO ingestion on plasma interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-alpha) and lipopolysaccharide (LPS)-stimulated neutrophil degranulation responses to high-intensity intermittent running. Six trained male soccer players performed 2 exercise trials, 7 days apart, in a randomized, counterbalanced design. On each occasion, they completed six 15-min periods of intermittent running consisting of maximal sprinting interspersed with less intense periods of running and walking. Subjects consumed either CHO or artificially sweetened placebo (PLA) beverages immediately before and at 15-min intervals during the exercise. At 30 min post-exercise, CHO versus PLA was associated with a higher plasma glucose concentration (p exercise, LPS-stimulated elastase release per neutrophil fell 31% below baseline values on the PLA trial (p = .06) compared with 17% on the CHO trial (p = .30). Plasma TNF-alpha concentration increased following the exercise (main effect of time, p attenuates changes in plasma IL-6 concentration, neutrophil trafficking, and LPS-stimulated neutrophil degranulation in response to intermittent exercise that involves bouts of very high intensity exercise.

  7. Models are likely to underestimate increase in heavy rainfall in the extratropical regions with high rainfall intensity

    Science.gov (United States)

    Borodina, Aleksandra; Fischer, Erich M.; Knutti, Reto

    2017-07-01

    Model projections of regional changes in heavy rainfall are uncertain. On timescales of few decades, internal variability plays an important role and therefore poses a challenge to detect robust model response in heavy rainfall to rising temperatures. We use spatial aggregation to reduce the major role of internal variability and evaluate the heavy rainfall response to warming temperatures with observations. We show that in the regions with high rainfall intensity and for which gridded observations exist, most of the models underestimate the historical scaling of heavy rainfall and the land fraction with significant positive heavy rainfall scalings during the historical period. The historical behavior is correlated with the projected heavy rainfall intensification across models allowing to apply an observational constraint, i.e., to calibrate multimodel ensembles with observations in order to narrow the range of projections. The constraint suggests a substantially stronger intensification of future heavy rainfall than the multimodel mean.

  8. Reflectivity of plasmas created by high-intensity, ultra-short laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Gold, D.M.

    1994-06-01

    Experiments were performed to characterize the creation and evolution of high-temperature (T{sub e}{approximately}100eV), high-density (n{sub e}>10{sup 22}cm{sup {minus}3}) plasmas created with intense ({approximately}10{sup 12}-10{sup 16}W/cm{sup 2}), ultra-short (130fs) laser pulses. The principle diagnostic was plasma reflectivity at optical wavelengths (614nm). An array of target materials (Al, Au, Si, SiO{sub 2}) with widely differing electronic properties tested plasma behavior over a large set of initial states. Time-integrated plasma reflectivity was measured as a function of laser intensity. Space- and time-resolved reflectivity, transmission and scatter were measured with a spatial resolution of {approximately}3{mu}m and a temporal resolution of 130fs. An amplified, mode-locked dye laser system was designed to produce {approximately}3.5mJ, {approximately}130fs laser pulses to create and nonintrusively probe the plasmas. Laser prepulse was carefully controlled to suppress preionization and give unambiguous, high-density plasma results. In metals (Al and Au), it is shown analytically that linear and nonlinear inverse Bremsstrahlung absorption, resonance absorption, and vacuum heating explain time-integrated reflectivity at intensities near 10{sup 16}W/cm{sup 2}. In the insulator, SiO{sub 2}, a non-equilibrium plasma reflectivity model using tunneling ionization, Helmholtz equations, and Drude conductivity agrees with time-integrated reflectivity measurements. Moreover, a comparison of ionization and Saha equilibration rates shows that plasma formed by intense, ultra-short pulses can exist with a transient, non-equilibrium distribution of ionization states. All targets are shown to approach a common reflectivity at intensities {approximately}10{sup 16}W/cm{sup 2}, indicating a material-independent state insensitive to atomic or solid-state details.

  9. A high-speed DAQ framework for future high-level trigger and event building clusters

    Science.gov (United States)

    Caselle, M.; Ardila Perez, L. E.; Balzer, M.; Dritschler, T.; Kopmann, A.; Mohr, H.; Rota, L.; Vogelgesang, M.; Weber, M.

    2017-03-01

    Modern data acquisition and trigger systems require a throughput of several GB/s and latencies of the order of microseconds. To satisfy such requirements, a heterogeneous readout system based on FPGA readout cards and GPU-based computing nodes coupled by InfiniBand has been developed. The incoming data from the back-end electronics is delivered directly into the internal memory of GPUs through a dedicated peer-to-peer PCIe communication. High performance DMA engines have been developed for direct communication between FPGAs and GPUs using "DirectGMA (AMD)" and "GPUDirect (NVIDIA)" technologies. The proposed infrastructure is a candidate for future generations of event building clusters, high-level trigger filter farms and low-level trigger system. In this paper the heterogeneous FPGA-GPU architecture will be presented and its performance be discussed.

  10. High temperature solar furnace: current applications and future potential

    Energy Technology Data Exchange (ETDEWEB)

    Bjorndalen, N. [Dalhousie Univ., Faculty of Engineering, Halifax, NS (Canada)

    2003-02-15

    The high temperature solar furnace can offer great opportunities for the production of many types of products worldwide, but recent advances in this technology have been limited to metal reduction. The production of semiconductors, which are utilized to a great extent in the electronic industry, is a viable option for this technology that has been overlooked. Especially where sand and sunlight are plentiful (countries that surround the equator), silicon chips produced with a solar furnace can have great economical value. This paper describes current and potential solar furnace technologies. The components of the solar furnace are described, as well as metal reduction processes including zinc and aluminum production. The viability of silicon chip production is also examined. The possibilities for other product development using an extremely (up to 10,000 deg C) high temperature solar furnace are also discussed. Economically, the benefits of solar furnaces are great, with only high initial start-up costs and little operation costs. Metal reduction processes can also be enhanced with high temperature solar furnaces in that plugging problems are eliminated. By replacing conventional furnaces, such as blast and electric arc furnaces, with a high temperature solar furnace, CO{sub 2} emissions and energy consumption can be greatly reduced, which will bring in added dividends to the society. (Author)

  11. Impact of the FUTURES series. [The impact of using the FUTURES Series on junior high school students

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-01

    The purpose of this study was to evaluate the effectiveness of the FUTURES series in affecting junior high school students' attitudes towards math and careers. FUTURES is a series of 12 programs designed to encourage positive attitudes in students towards math and science. The series illustrates their relevance to a variety of careers. The programs are hosted by Jaime Escalante and targeted to seventh to 12th grade students, with a special focus on minority students. This study looked at the long-term effects of the FUTURES series under classroom conditions. This study was designed to measure the effectiveness of the series in: (1) increasing positive attitudes toward math and science in school; (2) motivating students to have more positive attitudes about their future careers; (3) widening the possible choices of careers that involve the use of math and science; and, (4) creating an understanding of the relevance of math and science to careers and daily life. In addition, this study examined the appeal of the series, the students' understanding of program content, and how the series was used in the classroom.

  12. Ionization and acceleration of heavy ions in high-Z solid target irradiated by high intensity laser

    Science.gov (United States)

    Kawahito, D.; Kishimoto, Y.

    2016-05-01

    In the interaction between high intensity laser and solid film, an ionization dynamics inside the solid is dominated by fast time scale convective propagation of the internal sheath field and the slow one by impact ionization due to heated high energy electrons coupled with nonlocal heat transport. Furthermore, ionization and acceleration due to the localized external sheath field which co- propagates with Al ions constituting the high energy front in the vacuum region. Through this process, the maximum charge state and then q/A increase in the rear side, so that ions near the front are further accelerated to high energy.

  13. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Science.gov (United States)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Lu, W.; Xie, D. Z.; Hitz, D.; Zhang, X. Z.; Yang, Y.

    2017-09-01

    The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24-28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of 40Ar+ and 129Xe26+ have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL), China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24 +18 GHz ) heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  14. High intensity aerobic interval training improves peak oxygen consumption in patients with metabolic syndrome: CAT

    Directory of Open Access Journals (Sweden)

    Alexis Espinoza Salinas

    2014-06-01

    Full Text Available Introduction A number of cardiovascular risk factors characterizes the metabolic syndrome: insulin resistance (IR, low HDL cholesterol and high triglycerides. The aforementioned risk factors lead to elevated levels of abdominal adipose tissue, resulting in oxygen consumption deficiency. Purpose To verify the validity and applicability of using high intensity interval training (HIIT in subjects with metabolic syndrome and to answer the following question: Can HIIT improve peak oxygen consumption? Method The systematic review "Effects of aerobic interval training on exercise capacity and metabolic risk factors in individuals with cardiometabolic disorders" was analyzed. Results Data suggests high intensity aerobic interval training increases peak oxygen consumption by a standardized mean difference of 3.60 mL/kg-1/min-1 (95% confidence interval, 0.28-4.91. Conclusion In spite of the methodological shortcomings of the primary studies included in the systematic review, we reasonably conclude that implementation of high intensity aerobic interval training in subjects with metabolic syndrome, leads to increases in peak oxygen consumption.

  15. Postprandial lipoprotein profile in two modes of high-intensity intermittent exercise

    Science.gov (United States)

    Panissa, Valéria Leme Gonçalves; Julio, Ursula Ferreira; Diniz, Tiego Aparecido; de Moura Mello Antunes, Barbara; Lira, Fabio Santos; Takito, Monica Yuri; Franchini, Emerson

    2016-01-01

    The aim of present study was to compare blood lipid postprandial profile response in two modes of high-intensity intermittent exercise. Twelve individuals (6 men and 6 women) were submitted to a maximal incremental test (to determine maximal aerobic power [MAP] and V. O2peak [peak oxygen uptake]), high-intensity intermittent all-out exercise (60×8-sec bouts interspersed by 12-sec passive recovery) and fixed high-intensity intermittent exercise (100% maximal aerobic speed, consisted of 1-min repetitions at MAP [70 rpm] separated by 1-min of passive recovery). Blood samples were collected pre, immediately, 45 and 90-min postexercise. Serum was analyzed for total cholesterol and its ratio, high-density lipoprotein cholesterol (HDL-c), low-density lipoprotein cholesterol (LDL-c), very low-density lipoprotein (VLDL) cholesterol, and triacylglycerol (TAG). For TAG there was a main effect of moment with higher values immediately postexercise compared to 45-min postexercise. For VLDL there was a main effect to moment with higher values immediately post exercise than pre and 45-min postexercise; higher values 90-min postexercise than 45-min postexercise. There was no effect for HDL-c, LDL-c, and cholesterol. For area under the curve there was no difference for any variable. Our results indicated that both kinds of acute exercise session lead to no improvement in the acute response of serum lipid profile of healthy young. PMID:27807528

  16. REPORT OF THE SNOWMASS M6 WORKING GROUP ON HIGH INTENSITY PROTON SOURCES.

    Energy Technology Data Exchange (ETDEWEB)

    CHOU,W.; WEI,J.

    2001-08-14

    The M6 working group had more than 40 active participants (listed in Section 4). During the three weeks at Snowmass, there were about 50 presentations, covering a wide range of topics associated with high intensity proton sources. The talks are listed in Section 5. This group also had joint sessions with a number of other working groups, including E1 (Neutrino Factories and Muon Colliders), E5 (Fixed-Target Experiments), M1 (Muon Based Systems), T4 (Particle Sources), T5 (Beam dynamics), T7 (High Performance Computing) and T9 (Diagnostics). The M6 group performed a survey of the beam parameters of existing and proposed high intensity proton sources, in particular, of the proton drivers. The results are listed in Table 1. These parameters are compared with the requirements of high-energy physics users of secondary beams in Working Groups E1 and E5. According to the consensus reached in the E1 and E5 groups, the U.S. HEP program requires an intense proton source, a 1-4 MW Proton Driver, by the end of this decade.

  17. Report of the Snowmass M6 Working Group on high intensity proton sources

    Energy Technology Data Exchange (ETDEWEB)

    Weiren Chou and J. Wei

    2002-08-20

    The U.S. high-energy physics program needs an intense proton source, a 1-4 MW Proton Driver (PD), by the end of this decade. This machine will serve as a stand-alone facility that will provide neutrino superbeams and other high intensity secondary beams such as kaons, muons, neutrons, and anti-protons (cf. E1 and E5 group reports) and also serve as the first stage of a neutrino factory (cf. M1 group report). It can also be a high brightness source for a VLHC. Based on present accelerator technology and project construction experience, it is both feasible and cost-effective to construct a 1-4 MW Proton Driver. Two recent PD design studies have been made, one at FNAL and the other at the BNL. Both designed PD's for 1 MW proton beams at a cost of about U.S. $200M (excluding contingency and overhead) and both designs were upgradeable to 4 MW. An international collaboration between FNAL, BNL and KEK on high intensity proton facilities is addressing a number of key design issues. The superconducting (sc) RF cavities, cryogenics, and RF controls developed for the SNS can be directly adopted to save R&D efforts, cost, and schedule. PD studies are also actively being pursued at Europe and Japan.

  18. Energy gain and spectral tailoring of ion beams using ultra-high intensity laser beams

    Science.gov (United States)

    Prasad, Rajendra; Swantusch, Marco; Cerchez, Mirela; Spickermann, Sven; Auorand, Bastian; Wowra, Thomas; Boeker, Juergen; Willi, Oswald

    2015-11-01

    The field of laser driven ion acceleration over the past decade has produced a huge amount of research. Nowadays, several multi-beam facilities with high rep rate system, e.g. ELI, are being developed across the world for different kinds of experiments. The study of interaction dynamics of multiple beams possessing ultra-high intensity and ultra-short pulse duration is of vital importance. Here, we present the first experimental results on ion acceleration using two ultra-high intensity beams. Thanks to the unique capability of Arcturus laser at HHU Düsseldorf, two almost identical, independent beams in laser parameters such as intensity (>1020 W/cm2), pulse duration (30 fs) and contrast (>1010), could be accessed. Both beams are focused onto a 5 μm thin Ti target. While ensuring spatial overlap of the two beams, at relative temporal delay of ~ 50 ps (optimum delay), the proton and carbon ion energies were enhanced by factor of 1.5. Moreover, strong modulation in C4+ions near the high energy cut-off is observed later than the optimum delay for the proton enhancement. This offers controlled tailoring of the spectral content of heavy ions.

  19. High-intensity knee extensor training restores skeletal muscle function in COPD patients.

    Science.gov (United States)

    Brønstad, Eivind; Rognmo, Oivind; Tjonna, Arnt Erik; Dedichen, Hans Henrich; Kirkeby-Garstad, Idar; Håberg, Asta K; Bjørk Ingul, Charlotte; Wisløff, Ulrik; Steinshamn, Sigurd

    2012-11-01

    Improving reduced skeletal muscle function is important for optimising exercise tolerance and quality of life in chronic obstructive pulmonary disease (COPD) patients. By applying high-intensity training to a small muscle group, we hypothesised a normalisation of muscle function. Seven patients with COPD performed 6 weeks (3 days·week(-1)) of high-intensity interval aerobic knee extensor exercise training. Five age-matched healthy individuals served as a reference group. Muscle oxygen uptake and mitochondrial respiration of the vastus lateralis muscle were measured before and after the 6-week training programme. Initial peak work and maximal mitochondrial respiration were reduced in COPD patients and improved significantly after the training programme. Peak power and maximal mitochondrial respiration in vastus lateralis muscle increased to the level of the control subjects and were mainly mediated via improved complex I respiration. Furthermore, when normalised to citrate synthase activity, no difference in maximal respiration was found either after the intervention or compared to controls, suggesting normal functioning mitochondrial complexes. The present study shows that high-intensity training of a restricted muscle group is highly effective in restoring skeletal muscle function in COPD patients.

  20. Perceptual feeling and time-of-day effects on high intensity exercise performance

    Directory of Open Access Journals (Sweden)

    MARIE CLARE MCCORMICK

    2012-01-01

    Full Text Available The present study was designed to investigate the effect of time of day and perceptual feeling on high intensity cycle ergometry and related performance during ‘normal working hours’. Eleven male participants (22.9 ± 2.6yrs; 182 ± 0.06cm; 80.43 ± 14.39kg were tested over a 12 h period (08:00-20:00 h. Every hour, on the hour, participants performed a 10s maximal leg cycle ergometry test and completed an Exercise-Induced Feeling Inventory (EFI; every hour, on the half hour, they performed a standing broad jump (SBJ, hand grip test (HG and vertical jump (VJ. Participants were instructed that each test required maximum effort. The main results show that there were no significant differences during the 12h experimental period in any of the performance variables (P > 0.05. However, peak power output during the high intensity cycle ergometry and distance and height achieved during the SBJ and VJ test along with positive engagement all peaked at 19:00h. The results show that high intensity cycle ergometry and related physiological measures are not affected by the time of day during ‘normal working hours’. However, the data suggests that maximal performance is moderately affected by motivational levels of participants and therefore when using maximal exercise tests investigators should ensure that participants are highly motivated.

  1. Future Projection of Summer Extreme Precipitation from High Resolution Multi-RCMs over East Asia

    Science.gov (United States)

    Kim, Gayoung; Park, Changyong; Cha, Dong-Hyun; Lee, Dong-Kyou; Suh, Myoung-Seok; Ahn, Joong-Bae; Min, Seung-Ki; Hong, Song-You; Kang, Hyun-Suk

    2017-04-01

    Recently, the frequency and intensity of natural hazards have been increasing due to human-induced climate change. Because most damages of natural hazards over East Asia have been related to extreme precipitation events, it is important to estimate future change in extreme precipitation characteristics caused by climate change. We investigate future changes in extremal values of summer precipitation simulated by five regional climate models participating in the CORDEX-East Asia project (i.e., HadGEM3-RA, RegCM4, MM5, WRF, and GRIMs) over East Asia. 100-year return value calculated from the generalized extreme value (GEV) parameters is analysed as an indicator of extreme intensity. In the future climate, the mean values as well as the extreme values of daily precipitation tend to increase over land region. The increase of 100-year return value can be significantly associated with the changes in the location (intensity) and scale (variability) GEV parameters for extreme precipitation. It is expected that the results of this study can be used as fruitful references when making the policy of disaster management. Acknowledgements The research was supported by the Ministry of Public Safety and Security of Korean government and Development program under grant MPSS-NH-2013-63 and the National Research Foundation of Korea Grant funded by the Ministry of Science, ICT and Future Planning of Korea (NRF-2016M3C4A7952637) for its support and assistant in completion of the study.

  2. The future of OA in high-energy physics

    CERN Multimedia

    2008-01-01

    CERN 's SCOAP3 project has posted a summary of Rolf-Dieter Heuer's talk, Innovation in Scholarly Communication: Vision and Projects from High Energy Physics , at the Academic Publishing in Europe 2008 conference (Berlin, January 21-23, 2008). Heuer is the Research director of DESY and Director-General Elect of CERN .

  3. From High School to the Future: The Pathway to 20

    Science.gov (United States)

    Easton, John Q.; Ponisciak, Stephen; Luppescu, Stuart

    2008-01-01

    This research report points to a "major misalignment" between the standards set by the state ISAT tests in elementary school and the college-readiness standards expected of all juniors in Illinois high schools as measured by the ACT, which is part of the state's PSAE exams. CCSR authors John Easton, Stephen Ponisciak and Stuart Luppescu…

  4. Design and construction of a reverberation chamber for high-intensity acoustic testing.

    Science.gov (United States)

    Slusser, R. A.

    1973-01-01

    A high-intensity acoustic test facility was constructed at the Jet Propulsion Laboratory (JPL) to support the Mariner Mars 1971 project. For ease of construction, the reverberation chamber itself is rectangular, which resulted in very little sacrifice in acoustic performance. Levels as high as 156 dB can be achieved with the chamber empty and test levels of 150 dB have been used with a Mariner Mars spacecraft model (full size) in the chamber. Levels as high as this must be generated using electropneumatic transducers, which modulate gaseous nitrogen to this facility.

  5. Reactor target from metal chromium for "pure" high-intensive artificial neutrino source

    Science.gov (United States)

    Gavrin, V. N.; Kozlova, Yu. P.; Veretenkin, E. P.; Logachev, A. V.; Logacheva, A. I.; Lednev, I. S.; Okunkova, A. A.

    2017-01-01

    The paper presents the first results of development of manufacturing technology of metallic chromium targets from highly enriched isotope 50Cr for irradiation in a high flux nuclear reactor to obtain a compact high intensity neutrino source with low content of radionuclide impurities and minimum losses of enriched isotope. The main technological stages are the hydrolysis of chromyl fluoride, the electrochemical reduction of metallic chromium, the hot isostatic pressing of chromium powder and the electrical discharge machining of chromium bars. The technological stages of hot isostatic pressing of chromium powder and of electrical discharge machining of Cr rods have been tested.

  6. High intensity compact Compton X-ray sources: Challenges and potential of applications

    Energy Technology Data Exchange (ETDEWEB)

    Jacquet, M., E-mail: mjacquet@lal.in2p3.fr

    2014-07-15

    Thanks to the exceptional development of high power femtosecond lasers in the last 15 years, Compton based X-ray sources are in full development over the world in the recent years. Compact Compton sources are able to combine the compactness of the instrument with a beam of high intensity, high quality, tunable in energy. In various fields of applications such as biomedical science, cultural heritage preservation and material science researches, these sources should provide an easy working environment and the methods currently used at synchrotrons could be largely developed in a lab-size environment as hospitals, labs, or museums.

  7. Low volume short duration high-intensity interval training and repeated sprint ability in Gaelic football players

    OpenAIRE

    Kelly, David

    2014-01-01

    Gaelic Football is the most popular sport in Ireland and is characterized by irregular changes of pace and high-intensity efforts interspersed with periods of light to moderate intensity activity. Speed, power and aerobic capacity are essential fitness components for optimal performance during match play. A high level of aerobic conditioning is required to generate and maintain power output during repeated high intensity activities. Study 1: Anthropometric, physiological, metabolic and en...

  8. Specificity of high-intensity intermittent action remains important to MMA athletes' physical conditioning: response to Paillard (2011).

    Science.gov (United States)

    Del Vecchio, Fabrício Boscolo; Franchini, Emerson

    2013-02-01

    This response to Paillard (2011) focuses on the intermittent nature of mixed martial arts (MMA). It also emphasizes that the main goal of MMA athletes is to win by knockout or submission and that these actions normally are high-intensity actions or preceded by high-intensity actions. Additionally, there is evidence that high-intensity intermittent exercise protocols are able to improve aerobic fitness. It is important only to adjust physical training to the athletes' techniques and tactics.

  9. Blood flow regulation and oxygen uptake during high intensity forearm exercise.

    Science.gov (United States)

    Nyberg, Stian Kwak; Berg, Ole Kristian; Helgerud, Jan; Wang, Eivind

    2017-01-05

    The vascular strain is very high during heavy handgrip exercise, but the intensity and kinetics to reach peak blood flow, and peak oxygen uptake, are uncertain. We included 9 young (25±2yr) healthy males to evaluate blood flow and oxygen uptake responses during continuous dynamic handgrip exercise with increasing intensity. Blood flow was measured using Doppler-ultrasound and venous blood was drawn from a deep forearm vein to determine arteriovenous oxygen difference (a-vO2diff) during 6-minutes bouts of 60, 80 and 100% of maximal work rate (WRmax), respectively. Blood flow and oxygen uptake increased (pBlood velocity (49.5±11.5 cm∙sec(-1) to 58.1±11.6 cm∙sec(-1)) and brachial diameter (0.49±0.05cm to 0.50±0.06 cm) showed concomitant increases (pblood flow from 60% to 80%WRmax, while no differences were observed in a-vO2diff Shear rate also increased (pblood flow (60%WRmax:50±22s; 80%WRmax:51±20s; 100%WRmax:51±23s) than a-vO2diff (60%WRmax:29±9s; 80%WRmax:29±5s; 100%WRmax:20±5s), but not different from oxygen uptake (60%WRmax:44±25s; 80%WRmax:43±14s; 100%WRmax:41±32s). No differences were observed in MRT for blood flow or oxygen uptake with increased exercise intensity. In conclusion, when approaching maximal intensity, oxygen uptake appeared to reach a critical level at ~80% of WRmax and be regulated by blood flow. This implies that high, but not maximal, exercise intensity may be an optimal stimulus for shear stress-induced small muscle mass training adaptations.

  10. Interpretation of transverse tune spectra in a heavy-ion synchrotron at high intensities

    Directory of Open Access Journals (Sweden)

    R. Singh

    2013-03-01

    Full Text Available Two different tune measurement systems have been installed in the GSI Helmholtzzentrum für Schwerionenforschung heavy-ion synchrotron SIS-18. Tune spectra are obtained with high accuracy using these fast and sensitive systems. Besides the machine tune, the spectra contain information about the intensity dependent coherent tune shift and the incoherent space charge tune shift. The space charge tune shift is derived from a fit of the observed shifted positions of the synchrotron satellites to an analytic expression for the head-tail eigenmodes with space charge. Furthermore, the chromaticity is extracted from the measured head-tail mode structure. The results of the measurements provide experimental evidence of the importance of space charge effects and head-tail modes for the interpretation of transverse beam signals at high intensity.

  11. Interpretation of transverse tune spectra in a heavy-ion synchrotron at high intensities

    CERN Document Server

    Singh, R; Chorniy, O; Forck, P; Haseitl, R; Kaufmann, W; Kowina, P; Lang, K; Weiland, T

    2012-01-01

    Two different tune measurement systems have been installed in the GSI heavy-ion synchrotron SIS-18. Tune spectra are obtained with high accuracy using these fast and sensitive systems. Besides the machine tune, the spectra contain information about the intensity dependent coherent tune shift and the incoherent space charge tune shift. The space charge tune shift is derived from a fit of the observed shifted positions of the synchrotron satellites to an analytic expression for the head-tail eigenmodes with space charge. Furthermore, the chromaticity is extracted from the measured head-tail mode structure. The results of the measurements provide experimental evidence of the importance of space charge effects and head-tail modes for the interpretation of transverse beam signals at high intensity.

  12. Intracranial lesions with high signal intensity on T1-weighted MR images – review of pathologies

    Science.gov (United States)

    Zimny, Anna; Zińska, Lidia; Bladowska, Joanna; Neska-Matuszewska, Małgorzata; Sąsiadek, Marek

    2013-01-01

    Summary In the article we present pathological intracranial substances and lesions, which produce high signal intensity on T1-weighted MR images. Six groups of substances are discussed: 1. Gadolinium – based contrast agents, 2.hemoglobin degradation products (intra- and extra-cellular methemoglobin), 3. lipid-containing lesions (lipoma, dermoid cyst, implanted fatty materials, laminar cortical necrosis), 4. substances with high concentration of proteins (colloid cyst, craniopharyngioma, Rathke’s cleft cyst, ectopic posterior pituitary gland), 5. melanin (metastatic melanoma), 6. lesions containing mineral substances such as: calcium (calcifications, Fahr’s disease), copper (Wilson’s disease) and manganese (hepatic encephalopathy, manganese intoxication in intravenous drug abusers). Appropriate interpretation of signal intensity as well as analysis of location of lesions and clinical symptoms enables planning of further diagnostics and, in many cases, establishing the final diagnosis based on MR examination. PMID:24505222

  13. Short-term effects of implemented high intensity shoulder elevation during computer work

    DEFF Research Database (Denmark)

    Larsen, Mette K.; Samani, Afshin; Madeleine, Pascal

    2009-01-01

    elevation. RPE was reported, productivity (drawings per min) measured, and bipolar surface electromyography (EMG) recorded from the dominant upper trapezius during pauses and sessions of computer work. Repeated measure ANOVA with Bonferroni corrected post-hoc tests was applied for the statistical analyses......BACKGROUND: Work-site strength training sessions are shown effective to prevent and reduce neck-shoulder pain in computer workers, but difficult to integrate in normal working routines. A solution for avoiding neck-shoulder pain during computer work may be to implement high intensity voluntary...... contractions during the computer work. However, it is unknown how this may influence productivity, rate of perceived exertion (RPE) as well as activity and rest of neck-shoulder muscles during computer work. The aim of this study was to investigate short-term effects of a high intensity contraction...

  14. Electromagnetic cascade in high energy electron, positron, and photon interactions with intense laser pulses

    CERN Document Server

    Bulanov, S S; Esarey, E; Leemans, W P

    2013-01-01

    The interaction of high energy electrons, positrons, and photons with intense laser pulses is studied in head-on collision geometry. It is shown that electrons and/or positrons undergo a cascade-type process involving multiple emissions of photons. These photons can consequently convert into electron-positron pairs. As a result charged particles quickly lose their energy developing an exponentially decaying energy distribution, which suppresses the emission of high energy photons, thus reducing the number of electron-positron pairs being generated. Therefore, this type of interaction suppresses the development of the electromagnetic avalanche-type discharge, i.e., the exponential growth of the number of electrons, positrons, and photons does not occur in the course of interaction. The suppression will occur when 3D effects can be neglected in the transverse particle orbits, i.e., for sufficiently broad laser pulses with intensities that are not too extreme. The final distributions of electrons, positrons, and...

  15. Backcoupling of acoustic streaming on the temperature field inside high-intensity discharge lamps

    CERN Document Server

    Schwieger, Joerg; Wolff, Marcus; Manders, Freddy; Suijker, Jos

    2015-01-01

    Operating high-intensity discharge lamps in the high frequency range (20-300 kHz) provides energy-saving and cost reduction potentials. However, commercially available lamp drivers do not make use of this operating strategy because light intensity fluctuations and even lamp destruction are possible. The reason for the fluctuating discharge arc are acoustic resonances in this frequency range that are excited in the arc tube. The acoustic resonances in turn generate a fluid flow that is caused by the acoustic streaming effect. Here, we present a 3D multiphysics model to determine the influence of acoustic streaming on the temperature field in the vicinity of an acoustic eigenfrequency. In that case a transition from stable to instable behavior occurs. The model is able to predict when light flicker can be expected. The results are in very good accordance with accompanying experiments.

  16. A New Scheme for High-Intensity Laser-Driven Electron Acceleration in a Plasma 2

    CERN Document Server

    Sadykova, S P; Samkharadze, T G

    2015-01-01

    We propose a new approach to high-intensity relativistic laser-driven electron acceleration in a plasma. Here, we demonstrate that a plasma wave generated by a stimulated forward-scattering of an incident laser pulse can be in the longest acceleration phase with injected relativistic beam electrons. This is why the plasma wave has the maximum amplification coefficient which is determined by the acceleration time and the breakdown (overturn) electric field in which the acceleration of the injected beam electrons occurs. We must note that for the longest acceleration phase the relativity of the injected beam electrons plays a crucial role in our scheme. We estimate qualitatively the acceleration parameters of relativistic electrons in the field of a plasma wave generated at the stimulated forward-scattering of a high-intensity laser pulse in a plasma.

  17. Effects of High-Intensity Blood Flow Restriction Exercise on Muscle Fatigue

    Directory of Open Access Journals (Sweden)

    Neto Gabriel R.

    2014-07-01

    Full Text Available Strength training combined with blood flow restriction (BFR have been used to improve the levels of muscle adaptation. The aim of this paper was to investigate the acute effect of high intensity squats with and without blood flow restriction on muscular fatigue levels. Twelve athletes (aged 25.95 ± 0.84 years were randomized into two groups: without Blood Flow Restriction (NFR, n = 6 and With Blood Flow Restriction (WFR, n = 6 that performed a series of free weight squats with 80% 1-RM until concentric failure. The strength of the quadriceps extensors was assessed in a maximum voluntary isometric contraction integrated to signals from the surface electromyogram. The average frequency showed significant reductions in the WFR group for the vastus lateralis and vastus medialis muscles, and intergroup only for the vastus medialis. In conclusion, a set of squats at high intensity with BFR could compromise muscle strength immediately after exercise, however, differences were not significant between groups.

  18. High-power and low-intensity noise laser at 1064  nm.

    Science.gov (United States)

    Guiraud, Germain; Traynor, Nicholas; Santarelli, Giorgio

    2016-09-01

    We have developed a single-frequency, narrow-linewidth (Δνlaser operating at 1064 nm with a high output power (50 W). The laser is based on an ytterbium-doped fiber master oscillator power amplifier architecture with an output beam at the diffraction limit. An output power of 50 W is obtained with two amplification stages using a 50 mW diode laser seeder. We have carefully studied the relative intensity noise at each amplification stage. The detrimental effect due to stimulated Brillouin scattering on residual amplitude noise has been observed on the high-power booster stage. After careful optimization, this laser exhibits low intensity noise with a RMS value equal to 0.012% (1 kHz/10 MHz) at 50 W.

  19. Current status of high-intensity focused ultrasound for the management of uterine adenomyosis

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Vincent Y. T. [Dept. of Obstetrics and Gynaecology, Queen Mary Hospital, The University of Hong Kong, Hong Kong (China)

    2017-04-15

    While high-intensity focused ultrasound has been used for some time in the management of uterine fibroids, its effectiveness and safety in managing adenomyosis is less well established. A literature review was performed of all eligible reports using this modality as a treatment for adenomyosis. Relevant publications were obtained from the PubMed electronic database from inception through March 2016. Eleven articles, including information from 1,150 treatments and follow-up data from 990 patients, were reviewed. High-intensity focused ultrasound appears to be effective and safe in the management of symptomatic adenomyosis, and can be considered as an alternative uterine-sparing option for women with this condition.

  20. The Fermilab Main Injector: high intensity operation and beam loss control

    CERN Document Server

    Brown, Bruce C; Capista, David; Chou, Weiren; Kourbanis, Ioanis; Morris, Denton K; Seiya, Kiyomi; Wu, Guan Hong; Yang, Ming-Jen

    2013-01-01

    From 2005 through 2012, the Fermilab Main Injector provided intense beams of 120 GeV protons to produce neutrino beams and antiprotons. Hardware improvements in conjunction with improved diagnostics allowed the system to reach sustained operation at ~400 kW beam power. Transmission was very high except for beam lost at or near the 8 GeV injection energy where 95% beam transmission results in about 1.5 kW of beam loss. By minimizing and localizing loss, residual radiation levels fell while beam power was doubled. Lost beam was directed to either the collimation system or to the beam abort. Critical apertures were increased while improved instrumentation allowed optimal use of available apertures. We will summarize the improvements required to achieve high intensity, the impact of various loss control tools and the status and trends in residual radiation in the Main Injector.

  1. Status and future perspective of applications of high temperature superconductors

    Science.gov (United States)

    Tanaka, Shoji

    The material research on the high temperature superconductivity for the past ten years gave us sufficient information on the new phenomena of these new materials. It seems that new applications in a very wide range of industries are increasing rapidly. In this report three main topics of the applications are given ; [a] progress of the superconducting bulk materials and their applications to the flywheel electricity storage system and others, [b] progress in the development of superconducting tapes and their applications to power cables, the high field superconducting magnet for the SMES and for the pulling system of large silicon single crystal, and [c] development of new superconducting electronic devices (SFQ) and the possiblity of the application to next generation supercomputers. These examples show the great capability of the superconductivity technology and it is expected that the real superconductivity industry will take off around the year of 2005.

  2. Engineering the future with America's high school students

    Science.gov (United States)

    Farrance, M. A.; Jenner, J. W.

    1993-01-01

    The number of students enrolled in engineering is declining while the need for engineers is increasing. One contributing factor is that most high school students have little or no knowledge about what engineering is, or what engineers do. To teach young students about engineering, engineers need good tools. This paper presents a course of study developed and used by the authors in a junior college course for high school students. Students learned about engineering through independent student projects, in-class problem solving, and use of career information resources. Selected activities from the course can be adapted to teach students about engineering in other settings. Among the most successful techniques were the student research paper assignments, working out a solution to an engineering problem as a class exercise, and the use of technical materials to illustrate engineering concepts and demonstrate 'tools of the trade'.

  3. Plastic straw: future of high-speed signaling

    Science.gov (United States)

    Song, Ha Il; Jin, Huxian; Bae, Hyeon-Min

    2015-11-01

    The ever-increasing demand for bandwidth triggered by mobile and video Internet traffic requires advanced interconnect solutions satisfying functional and economic constraints. A new interconnect called E-TUBE is proposed as a cost-and-power-effective all-electrical-domain wideband waveguide solution for high-speed high-volume short-reach communication links. The E-TUBE achieves an unprecedented level of performance in terms of bandwidth-per-carrier frequency, power, and density without requiring a precision manufacturing process unlike conventional optical/waveguide solutions. The E-TUBE exhibits a frequency-independent loss-profile of 4 dB/m and has nearly 20-GHz bandwidth over the V band. A single-sideband signal transmission enabled by the inherent frequency response of the E-TUBE renders two-times data throughput without any physical overhead compared to conventional radio frequency communication technologies. This new interconnect scheme would be attractive to parties interested in high throughput links, including but not limited to, 100/400 Gbps chip-to-chip communications.

  4. Ion source choices - an h- source for the high intensity neutrino source

    Energy Technology Data Exchange (ETDEWEB)

    Moehs, Douglas P.; /Fermilab; Welton, Robert F.; /SNS Project, Oak Ridge; Stockli, Martin P.; Peters, Jens; /DESY; Alessi, James; /Brookhaven

    2006-08-01

    The High Intensity Neutrino Source (HINS) program at Fermilab (formerly the Proton Driver) aims to develop a multi-mission linear accelerator (LINAC) capable of accelerate H{sup -} ions to 8 GeV. This paper touches on the ion source requirements for the HINS and discusses long pulse length testing of three ion sources which appear to have the capability of meeting these requirements.

  5. Lymphocyte Redox Imbalance and Reduced Proliferation after a Single Session of High Intensity Interval Exercise

    OpenAIRE

    Tossige-Gomes, Rosalina; Costa, Karine Beatriz; Ottone, Vinícius de Oliveira; Magalhães, Flávio de Castro; Amorim, Fabiano Trigueiro; Rocha-Vieira, Etel

    2016-01-01

    This study investigated whether an acute session of high-intensity interval training (HIIT) is sufficient to alter lymphocyte function and redox status. Sixteen young healthy men underwent a HIIT session on a cycloergometer, consisting of eight bouts of 1 min at 90–100% of peak power, with 75 seconds of active recovery at 30 W between bouts. Venous blood was collected before, immediately after, and 30 minutes after the HIIT session. In response to Staphylococcus aureus superantigen B (SEB) st...

  6. High-intensity focused ultrasound to treat primary hyperparathyroidism: a feasibility study in four patients

    DEFF Research Database (Denmark)

    Kovatcheva, Roussanka D; Vlahov, Jordan D; Shinkov, Alexander D;

    2010-01-01

    Many patients with primary hyperparathyroidism either decline or are not candidates for surgical parathyroidectomy. There are drawbacks to medical therapy as well as percutaneous ethanol injection as alternative therapies for primary hyperparathyroidism. Therefore, in this pilot study, our aim...... was to test the feasibility, safety, and efficacy of a newly developed noninvasive high-intensity focused ultrasound (HIFU) technique for the nonsurgical management of primary hyperparathyroidism....

  7. MR-guided high-intensity focused ultrasound treatment of uterine fibroids

    OpenAIRE

    2016-01-01

    Antonia Wiggermann,1 Michael Beldoch,1 Friederike Hoellen,2 Peter Hunold1 1Clinic for Radiology and Nuclear Medicine, 2Department of Obstetrics and Gynecology, University Hospital Schleswig-Holstein, Lübeck, Germany Abstract: Uterine fibroids are benign, encapsulated uterine tumors, representing the most common reason for hysterectomy in premenopausal women. High-intensity focused ultrasound (HIFU; also known as focused ultrasound surgery) is a noninvasive technique leading to tissu...

  8. Modelling of radiation losses for ion acceleration at ultra-high laser intensities

    Directory of Open Access Journals (Sweden)

    Capdessus Remi

    2013-11-01

    Full Text Available Radiation losses of charged particles can become important in ultra high intensity laser plasma interaction. This process is described by the radiation back reaction term in the electron equation of motion. This term is implemented in the relativistic particle-in-cell code by using a renormalized Lorentz-Abraham-Dirac model. In the hole boring regime case of laser ion acceleration it is shown that radiation losses results in a decrease of the piston velocity.

  9. A Rectourethral Fistula due to Transrectal High-Intensity Focused Ultrasound Treatment: Diagnosis and Management

    OpenAIRE

    2012-01-01

    Colovesical fistula (CVF) is an abnormal connection between the enteric and the urinary systems. The rectourethral fistula (RUF) is a possible but extremely rare complication of treatment of prostate cancer with “transrectal High-Intensity Focused Ultrasound (HIFU) treatment.” We present a case of CVF due to HIFU treatment of recurrent prostate cancer. The case was assessed with cystography completed with a pelvic CT scan—with MPR, MIP, and VR reconstruction—before emptying the bladder. Since...

  10. High-intensity cycle interval training improves cycling and running performance in triathletes.

    Science.gov (United States)

    Etxebarria, Naroa; Anson, Judith M; Pyne, David B; Ferguson, Richard A

    2014-01-01

    Effective cycle training for triathlon is a challenge for coaches. We compared the effects of two variants of cycle high-intensity interval training (HIT) on triathlon-specific cycling and running. Fourteen moderately-trained male triathletes ([Formula: see text]O2peak 58.7 ± 8.1 mL kg(-1) min(-1); mean ± SD) completed on separate occasions a maximal incremental test ([Formula: see text]O2peak and maximal aerobic power), 16 × 20 s cycle sprints and a 1-h triathlon-specific cycle followed immediately by a 5 km run time trial. Participants were then pair-matched and assigned randomly to either a long high-intensity interval training (LONG) (6-8 × 5 min efforts) or short high-intensity interval training (SHORT) (9-11 × 10, 20 and 40 s efforts) HIT cycle training intervention. Six training sessions were completed over 3 weeks before participants repeated the baseline testing. Both groups had an ∼7% increase in [Formula: see text]O2peak (SHORT 7.3%, ±4.6%; mean, ±90% confidence limits; LONG 7.5%, ±1.7%). There was a moderate improvement in mean power for both the SHORT (10.3%, ±4.4%) and LONG (10.7%, ±6.8%) groups during the last eight 20-s sprints. There was a small to moderate decrease in heart rate, blood lactate and perceived exertion in both groups during the 1-h triathlon-specific cycling but only the LONG group had a substantial decrease in the subsequent 5-km run time (64, ±59 s). Moderately-trained triathletes should use both short and long high-intensity intervals to improve cycling physiology and performance. Longer 5-min intervals on the bike are more likely to benefit 5 km running performance.

  11. Circulating adiponectin concentration and body composition are altered in response to high-intensity interval training.

    Science.gov (United States)

    Shing, Cecilia M; Webb, Jessica J; Driller, Matthew W; Williams, Andrew D; Fell, James W

    2013-08-01

    Adiponectin influences metabolic adaptations that would prove beneficial to endurance athletes, and yet to date there is little known about the response of adiponectin concentrations to exercise, and, in particular, the response of this hormone to training in an athlete population. This study aimed to determine the response of plasma adiponectin concentrations to acute exercise after 2 different training programs and to determine the influence of the training on body composition. Seven state-level representative rowers (age: 19 ± 1.2 years [mean ± SD], height: 1.77 ± 0.10 m, body mass: 74.0 ± 10.7 kg, VO2peak 62.1 ± 7.0 ml·kg·min) participated in the double-blind, randomized crossover investigation. Rowers performed an incremental graded exercise test before and after completing 4 weeks of high-intensity interval ergometer training and 4 weeks of traditional ergometer rowing training. Rowers' body composition was assessed at baseline and after each training program. Significant increases in plasma adiponectin concentration occurred in response to maximal exercise after completion of the high-intensity interval training (p = 0.016) but not after traditional ergometer rowing training (p = 0.69). The high-intensity interval training also resulted in significant increases in mean 4-minute power output (p = 0.002) and VO2peak (p = 0.05), and a decrease in body fat percentage (p = 0.022). Mean 4-minute power output, VO2peak, and body fat percentage were not significantly different after 4 weeks of traditional ergometer rowing training (p > 0.05). Four weeks of high-intensity interval training is associated with an increase in adiponectin concentration in response to maximal exercise and a reduction in body fat percentage. The potential for changes in adiponectin concentration to reflect positive training adaptations and athlete performance level should be further explored.

  12. Study of Radiation Damage in Lead Tungstate Crystals Using Intense High Energy Beams

    CERN Document Server

    Batarin, V; Butler, J; Cheung, H; Datsko, V S; Davidenko, A; Derevshchikov, A A; Dzhelyadin, R I; Fomin, Y; Frolov, V; Goncharenko, Yu M; Grishin, V; Kachanov, V A; Khodyrev, V Yu; Khroustalev, K; Konoplyannikov, A K; Konstantinov, A S; Kravtsov, V; Kubota, Y; Leontiev, V M; Lukanin, V S; Maisheev, V; Matulenko, Yu A; Melnik, Yu M; Meshchanin, A P; Mikhalin, N; Minaev, N G; Mochalov, V; Morozov, D A; Mountain, R; Nogach, L V; Pikalov, V A; Ryazantsev, A; Semenov, P A; Shestermanov, K E; Soloviev, L; Solovyanov, V L; Stone, S; Ukhanov, M N; Uzunian, A V; Vasilev, A; Yakutin, A; Yarba, J V

    2003-01-01

    We report on the effects of radiation on the light output of lead tungstate crystals. The crystals were irradiated by pure, intense high energy electron and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai (China). These studies were carried out at the 70-GeV proton accelerator in Protvino.

  13. Study of radiation damage in lead tungstate crystals using intense high-energy beams

    Energy Technology Data Exchange (ETDEWEB)

    Batarin, V.A.; Brennan, T.; Butler, J.; Cheung, H.; Datsko, V.S.; Davidenko, A.M.; Derevschikov, A.A.; Dzhelyadin, R.I.; Fomin, Y.V.; Frolov, V.; Goncharenko, Y.M.; Grishin, V.N.; Kachanov, V.A.; Khodyrev, V.Y.; Khroustalev, K.; Konoplyannikov, A.K.; Konstantinov, A.S.; Kravtsov, V.I.; Kubota, Y.; Leontiev, V.M.; Lukanin, V.S.; Maisheev, V.A.; Matulenko, Y.A.; Melnick, Y.M.; Meschanin, A.P.; Mikhalin, N.E.; Minaev, N.G.; Mochalov, V.V.; Morozov, D.A.; Mountain, R.; Nogach, L.V.; Pikalov, V.A.; Ryazantsev, A.V.; Semenov, P.A. E-mail: semenov@mx.ihep.su; Shestermanov, K.E.; Soloviev, L.F.; Solovianov, V.L.; Stone, S.; Ukhanov, M.N.; Uzunian, A.V.; Vasiliev, A.N.; Yakutin, A.E.; Yarba, J

    2003-10-21

    We report on the effects of radiation on the light output of lead tungstate crystals. The crystals were irradiated by pure, intense high-energy electron and hadron beams as well as by a mixture of hadrons, neutrons and gammas. The crystals were manufactured in Bogoroditsk, Apatity (both Russia), and Shanghai (China). These studies were carried out at the 70-GeV proton accelerator in Protvino.

  14. Laser-enhanced cavitation during high intensity focused ultrasound: An in vivo study

    OpenAIRE

    Cui, Huizhong; Zhang, Ti; Yang, Xinmai

    2013-01-01

    Laser-enhanced cavitation during high intensity focused ultrasound (HIFU) was studied in vivo using a small animal model. Laser light was employed to illuminate the sample concurrently with HIFU radiation. The resulting cavitation was detected with a passive cavitation detector. The in vivo measurements were made under different combinations of HIFU treatment depths, laser wavelengths, and HIFU durations. The results demonstrated that concurrent light illumination during HIFU has the potentia...

  15. Continuous and high-intensity interval training: which promotes higher pleasure?

    Directory of Open Access Journals (Sweden)

    Bruno R R Oliveira

    Full Text Available OBJECTIVES: To compare the psychological responses to continuous (CT and high-intensity interval training (HIT sessions. METHODS: Fifteen men attended one CT session and one HIT session. During the first visit, the maximum heart rate, VO2Peak and respiratory compensation point (RCP were determined through a maximal cardiopulmonary exercise test. The HIT stimulus intensity corresponded to 100% of VO2Peak, and the average intensity of both sessions was maintained at 15% below the RCP. The order of the sessions was randomized. Psychological and physiological variables were recorded before, during and after each session. RESULTS: There were no significant differences between the average percentages of VO2 during the two exercise sessions (HIT: 73.3% vs. CT: 71.8%; p = 0.779. Lower responses on the feeling scale (p≤0.01 and higher responses on the felt arousal scale (p≤0.001 and the rating of perceived exertion were obtained during the HIT session. Despite the more negative feeling scale responses observed during HIT and a greater feeling of fatigue (measured by Profile of Mood States afterwards (p<0.01, the physical activity enjoyment scale was not significantly different between the two conditions (p = 0.779. CONCLUSION: Despite the same average intensity for both conditions, similar psychological responses under HIT and CT conditions were not observed, suggesting that the higher dependence on anaerobic metabolism during HIT negatively influenced the feeling scale responses.

  16. Aspects of operation of the Fermilab Booster RF System at very high intensity

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, J.E.

    1996-04-01

    The purpose of this note is to examine the likelihood and problems associated with operation of the Fermilab Booster rf systems as it presently exists, or with only minor modifications, at beam intensity approaching 5x10{sup 13} protons per pulse. Beam loading of the rf system at such an intensity will be one order of magnitude larger than at the present operation level. It is assumed that the injection energy will be raised to 1 GeV with no major increase in the injected energy spread (longitudinal emittance). The beam will be bunched by adiabatic capture as is presently done although it may be necessary to remove one or two bunches prior to acceleration to allow clean extraction at 8 GeV. At very high intensity the charge in each bunch will interact with the vacuum chamber impedance (and with itself) in such a way as to reduce in some cases the bucket area generated by the rf voltage. Because this decrement must be made up by changes in the rf ring voltage if the required bucket area is to be maintained, these effects must be taken into consideration in any analysis of the capability of the rf system to accelerate very large intensity.

  17. Electromagnetic cascade in high-energy electron, positron, and photon interactions with intense laser pulses

    Science.gov (United States)

    Bulanov, S. S.; Schroeder, C. B.; Esarey, E.; Leemans, W. P.

    2013-06-01

    The interaction of high-energy electrons, positrons, and photons with intense laser pulses is studied in head-on collision geometry. It is shown that electrons and/or positrons undergo a cascade-type process involving multiple emissions of photons. These photons can consequently convert into electron-positron pairs. As a result charged particles quickly lose their energy developing an exponentially decaying energy distribution, which suppresses the emission of high-energy photons, thus reducing the number of electron-positron pairs being generated. Therefore, this type of interaction suppresses the development of the electromagnetic avalanche-type discharge, i.e., the exponential growth of the number of electrons, positrons, and photons does not occur in the course of interaction. The suppression will occur when three-dimensional effects can be neglected in the transverse particle orbits, i.e., for sufficiently broad laser pulses with intensities that are not too extreme. The final distributions of electrons, positrons, and photons are calculated for the case of a high-energy e-beam interacting with a counterstreaming, short intense laser pulse. The energy loss of the e-beam, which requires a self-consistent quantum description, plays an important role in this process, as well as provides a clear experimental observable for the transition from the classical to quantum regime of interaction.

  18. Controlled generation of high-intensity optical rogue waves by induced modulation instability.

    Science.gov (United States)

    Zhao, Saili; Yang, Hua; Chen, Nengsong; Zhao, Chujun

    2017-01-04

    Optical rogue waves are featured as the generation of high amplitude events at low probability in optical systems. Moreover, the formation of optical rogue waves is unpredictable and transient in photonic crystal fibers. In this paper, we put forward a method to generate high-intensity optical rogue waves in a more controlled way based on induced modulation instability, which can suppress the noise effect and hence play a leading role in the process of pulse evolution. Our numerical simulations indicate that the generation of rogue wave can be controlled when seeding at the optimal modulation frequency and the intensity of rogue wave can be enhanced with appropriate modulation depth. Further, high-intensity rogue wave can also be ejected in the fiber with a shorter propagation length by regulating the modulation depth. These results all provide a better understanding of optical rogue wave, which can contribute to the generation of tunable long-wavelength spectral components and selective excitation of mid-infrared supercontinuum.

  19. The effect of an intermittent, high-intensity warm-up on supramaximal kayak ergometer performance.

    Science.gov (United States)

    Bishop, David; Bonetti, Darrel; Spencer, Matthew

    2003-01-01

    It has previously been shown that the metabolic acidaemia induced by a continuous warm-up at the 'lactate threshold' is associated with a reduced accumulated oxygen deficit and decreased supramaximal performance. The aim of this study was to determine if an intermittent, high-intensity warm-up could increase oxygen uptake (VO2) without reducing the accumulated oxygen deficit, and thus improve supramaximal performance. Seven male 500 m kayak paddlers, who had represented their state, volunteered for this study. Each performed a graded exercise test to determine VO2max and threshold parameters. On subsequent days and in a random, counterbalanced order, the participants then performed a continuous or intermittent, high-intensity warm-up followed by a 2 min, all-out kayak ergometer test. The continuous warm-up consisted of 15 min of exercise at approximately 65% VO2max. The intermittent, high-intensity warm-up was similar, except that the last 5 min was replaced with five 10 s sprints at 200% VO2max, separated by 50 s of recovery at approximately 55% VO2max. Significantly greater (P kayak ergometer performance is significantly better after an intermittent rather than a continuous warm-up.

  20. Repeated High Intensity Bouts with Long Recovery: Are Bicarbonate or Carbohydrate Supplements an Option?

    Directory of Open Access Journals (Sweden)

    Thomas Stöggl

    2014-01-01

    Full Text Available The effects of varying recovery modes and the influence of preexercise sodium bicarbonate and carbohydrate ingestion on repeated high intensity performance, acid-base response, and recovery were analyzed in 12 well-trained males. They completed three repeated high intensity running bouts to exhaustion with intervening recovery periods of 25 min under the following conditions: sodium bicarbonate, active recovery (BIC; carbohydrate ingestion, active recovery (CHO; placebo ingestion, active recovery (ACTIVE; placebo ingestion, passive recovery (PASSIVE. Blood lactate (BLa, blood gases, heart rate, and time to exhaustion were collected. The three high intensity bouts had a duration of 138±9, 124±6, and 121±6 s demonstrating a decrease from bout 1 to bout 3. Supplementation strategy had no effect on performance in the first bout, even with differences in pH and bicarbonate (HCO3-. Repeated sprint performance was not affected by supplementation strategy when compared to ACTIVE, while PASSIVE resulted in a more pronounced decrease in performance compared with all other interventions. BIC led to greater BLa, pH, and HCO3- values compared with all other interventions, while for PASSIVE the opposite was found. BLa recovery was lowest in PASSIVE; recovery in pH, and HCO3- was lower in PASSIVE and higher in BIC.