WorldWideScience

Sample records for functional reach test

  1. Validity of an Interactive Functional Reach Test.

    Science.gov (United States)

    Galen, Sujay S; Pardo, Vicky; Wyatt, Douglas; Diamond, Andrew; Brodith, Victor; Pavlov, Alex

    2015-08-01

    Videogaming platforms such as the Microsoft (Redmond, WA) Kinect(®) are increasingly being used in rehabilitation to improve balance performance and mobility. These gaming platforms do not have built-in clinical measures that offer clinically meaningful data. We have now developed software that will enable the Kinect sensor to assess a patient's balance using an interactive functional reach test (I-FRT). The aim of the study was to test the concurrent validity of the I-FRT and to establish the feasibility of implementing the I-FRT in a clinical setting. The concurrent validity of the I-FRT was tested among 20 healthy adults (mean age, 25.8±3.4 years; 14 women). The Functional Reach Test (FRT) was measured simultaneously by both the Kinect sensor using the I-FRT software and the Optotrak Certus(®) 3D motion-capture system (Northern Digital Inc., Waterloo, ON, Canada). The feasibility of implementing the I-FRT in a clinical setting was assessed by performing the I-FRT in 10 participants with mild balance impairments recruited from the outpatient physical therapy clinic (mean age, 55.8±13.5 years; four women) and obtaining their feedback using a NASA Task Load Index (NASA-TLX) questionnaire. There was moderate to good agreement between FRT measures made by the two measurement systems. The greatest agreement between the two measurement system was found with the Kinect sensor placed at a distance of 2.5 m [intraclass correlation coefficient (2,k)=0.786; PNASA/TLX questionnaire. FRT measures made using the Kinect sensor I-FRT software provides a valid clinical measure that can be used with the gaming platforms.

  2. Functional reach and lateral reach tests adapted for aquatic physical therapy

    Directory of Open Access Journals (Sweden)

    Ana Angélica Ribeiro de Lima

    Full Text Available Abstract Introduction: Functional reach (FR and lateral reach (LR tests are widely used in scientific research and clinical practice. Assessment tools are useful in assessing subjects with greater accuracy and are usually adapted according to the limitations of each condition. Objective: To adapt FR and LR tests for use in an aquatic environment and assess the performance of healthy young adults. Methods: We collected anthropometric data and information on whether the participant exercised regularly or not. The FR and LR tests were adapted for use in an aquatic environment and administered to 47 healthy subjects aged 20-30 years. Each test was repeated three times. Results: Forty-one females and six males were assessed. The mean FR test score for men was 24.06 cm, whereas the mean value for right lateral reach (RLR was 10.94 cm and for left lateral reach (LLR was 9.78 cm. For females, the mean FR score was 17.57 cm, while the mean values for RLR was 8.84cm and for LLR was 7.76 cm. Men performed better in the FR (p < 0.001 and RLR tests than women (p = 0.037. Individuals who exercised regularly showed no differences in performance level when compared with their counterparts. Conclusion: The FR and LR tests were adapted for use in an aquatic environment. Males performed better on the FR and RLR tests, when compared to females. There was no correlation between the FR and LR tests and weight, height, Body Mass Index (BMI, foot length or length of the dominant upper limb.

  3. Teratology testing under REACH.

    Science.gov (United States)

    Barton, Steve

    2013-01-01

    REACH guidelines may require teratology testing for new and existing chemicals. This chapter discusses procedures to assess the need for teratology testing and the conduct and interpretation of teratology tests where required.

  4. CORRELATION OF LOW BACK PAIN WITH BODY MASS INDEX, FUNCTIONAL REACH TEST AMONG FEMALE NURSING PROFESSIONALS

    Directory of Open Access Journals (Sweden)

    Shameela .T .V

    2015-12-01

    Full Text Available Background: Among health care workers the highest level of work related back injuries are more affected in nurses. There were many studies done to assess low back pain by using different tools. So this study aimed to identify the prevalence low back pain disability among female nursing professionals and the association between BMI, functional reach test and low back pain, so that a better tool can be used during the clinical examination for the betterment of the patient. The objective of the study is to identify the prevalence of low back pain disability, the association of Low Back Pain(LBP with BMI and functional reach test among female nursing professionals. Methods: A total of 256 subjects were assessed for disability due to back pain using OswestryLBP Disability Questionnaire and the prevalence of disability was determined. The sit and reach test, forward reach test and their BMI were calculated for those who had a disability score of 20 and above (n=87. Results: Data was analyzed using Pearson’s correlation.The study result showed a significant correlation (p=0.03 of sit and reach test with low back pain disability scores. There was a negative correlationseen among BMI and LBP disability score forward reach test and LBP disability score, and BMI and no low back pain disability score. Conclusion: The prevalence of LBP disability among nursing professionals was 33.9%. This study suggest that sit and reach test can be used as an indicator of low back pain. Whereas BMI and forward reach test do not indicate low back pain.

  5. NORMAL VALUES AND FACTORS AFFECTING FUNCTIONAL REACH TEST IN SAUDI ARABIA SCHOOL CHILDREN WITH TYPICAL DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    Hatem A. Emara

    2015-10-01

    Full Text Available Background: The most critical feature of motor development is the ability to balance the body in sitting or standing. Impaired balance limits a child’s ability to recover from unexpected threats to stability. The functional reach test (FRT defines the maximal distance an individual is able to reach forward beyond arm’s length in a standing position without loss of balance, taking a step, or touching the wall. The Purpose of this study was to establish the normal values for FRT in Saudi Arabia school children with typical development and to study the correlation of anthropometric measures with FRT values. Methods: This cross-sectional study was conducted in Almadinah Almonawarah, Kingdom of Saudi Arabia. A total of 280 children without disabilities aged 6 to 12 years were randomly selected. Functional reach was assessed by having subjects extend their arms to 90 degrees and reach as far forward as they could without taking a step. Reach distance was recorded by noting the beginning and final position of the subject's extended arm parallel to a yard stick attached to the wall. Three successive trials of FRT were performed and the mean of the three trials was calculated. Pearson product moment correlation was used to examine the association of FR to age, and anthropometric measures. Results: Normal mean values of FR ranged from 24.2cm to 33.95cm. Age, height and weight significantly correlate with FRT. Conclusion: The FRT is a feasible test to examine the balance of 6-12 year-old children. FRT may be useful for detecting balance impairment, change in balance performance over time.

  6. Simple and easy assessment of falling risk in the elderly by functional reach test using elastic stick.

    Science.gov (United States)

    Demura, Shin-Ichi; Yamada, Takayoshi

    2007-10-01

    Dynamic balance ability related to maintaining postural stability during movement is closely tied to fall risk in the elderly. The functional reach (FR) test has been developed to evaluate their dynamic balance. Although a simple and new FR test using an elastic stick has been proposed by modifying the above original FR test, the abilities related to both FR tests are judged to differ because of the large difference in the testing method. This study aimed to compare center of gravity fluctuation, muscle activity and functional reach distance as measured by the original FR test and the elastic stick FR test. First, reach distance, back/forth and right/left moving distance of the center of gravity, and activity of the lower leg muscles (soleus and tibialis anterior) were compared between both tests based on data obtained from 30 young male adults. All parameters except for the right/left moving distance were significantly larger in the elastic stick FR test. Next, the reach distance was examined in both FR tests using 53 elderly subjects; it was significantly longer in the elastic stick FR test, but showed no significant sex difference. The reach distance in both tests was significantly shorter (about 7 cm) in the elderly than in young adults. In conclusion, the elastic stick FR test involves greater leg muscle strength exertion and forward transferring of the center of gravity as compared with the original FR test. Because the elastic stick FR test relates largely to leg muscle function and equilibrium function, it may be more useful for evaluating the dynamic balance ability of the elderly.

  7. Normative data of Modified Functional Reach Test in younger and middle-aged North Eastern Indian population

    Directory of Open Access Journals (Sweden)

    Priyanka Singh

    2013-01-01

    Full Text Available Background and Purpose: The modified functional reach test (MFRT is the objective measure for dynamic sitting balance. It quantifies sitting balance in two directions: Forward and lateral reach. So, the purpose of the study was to 1 provide clinical reference value and 2 examine the factors that may influence the anthropometrics measures. Materials and Methods: A total of 200 apparently healthy subjects participated in this descriptive study. All subjects were divided in two groups: Younger (20-39 yr and middle-aged (40-59 yr. After anthropometric measurement, all subjects performed test by reaching forward and lateral with a closed fist while sitting. MFRT was taken with 3 trials with 15 sec break in between. Results: The mean score of the forward and lateral reach of right and left in group 1 was higher compared to group 2. The normative value of forward reach in group 1 was 34.05 ± 9.03 cm; for lateral reach right and left, it was 18.2 ± 5.26 cm and 17.32 ± 5.21 cm, respectively. For group 2, normative values for forward reach, lateral right and left were 25.18 ± 5.71 cm, 14.02 ± 3.98 cm and 13.53 ± 4.25 cm, respectively. There was no significant correlation of forward and lateral reach measures with the anthropometric characteristics in both the groups, except trunk length and BMI in group 1, which was significantly correlated ( P < 0.001. Conclusion: This study provides clinical reference value for younger and middle age group subjects while anthropometrics do not affect performance except trunk length and BMI in younger age group.

  8. Are the Timed Up and Go Test and Functional Reach Test Useful Predictors of Temporal and Spatial Gait Parameters in Elderly People?

    Directory of Open Access Journals (Sweden)

    Sadowska Dorota

    2016-09-01

    Full Text Available Purpose. The study aim was to analyse the relationships between the results of the Timed Up and Go (TUG test and the Functional Reach Test (FRT, and the temporal and spatial gait parameters determined with the GAITRite system.

  9. Using the Functional Reach Test for Probing the Static Stability of Bipedal Standing in Humanoid Robots Based on the Passive Motion Paradigm

    Directory of Open Access Journals (Sweden)

    Jacopo Zenzeri

    2013-01-01

    Full Text Available The goal of this paper is to analyze the static stability of a computational architecture, based on the Passive Motion Paradigm, for coordinating the redundant degrees of freedom of a humanoid robot during whole-body reaching movements in bipedal standing. The analysis is based on a simulation study that implements the Functional Reach Test, originally developed for assessing the danger of falling in elderly people. The study is carried out in the YARP environment that allows realistic simulations with the iCub humanoid robot.

  10. Extending the Reach of Statistical Software Testing

    National Research Council Canada - National Science Library

    Weber, Robert

    2004-01-01

    .... In particular, as system complexity increases, the matrices required to generate test cases and perform model analysis can grow dramatically, even exponentially, overwhelming the test generation...

  11. Integrated testing strategy (ITS) for bioaccumulation assessment under REACH

    DEFF Research Database (Denmark)

    Lombardo, Anna; Roncaglioni, Alessandra; Benfentati, Emilio

    2014-01-01

    in a dossier. REACH promotes the use of alternative methods to replace, refine and reduce the use of animal (eco)toxicity testing. Within the EU OSIRIS project, integrated testing strategies (ITSs) have been developed for the rational use of non-animal testing approaches in chemical hazard assessment. Here we......REACH (registration, evaluation, authorisation and restriction of chemicals) regulation requires that all the chemicals produced or imported in Europe above 1 tonne/year are registered. To register a chemical, physicochemical, toxicological and ecotoxicological information needs to be reported...... present an ITS for evaluating the bioaccumulation potential of organic chemicals. The scheme includes the use of all available data (also the non-optimal ones), waiving schemes, analysis of physicochemical properties related to the end point and alternative methods (both in silico and in vitro). In vivo...

  12. Thyroid Function Tests

    Science.gov (United States)

    ... Home » Thyroid Function Tests Leer en Español Thyroid Function Tests FUNCTION HOW DOES THE THYROID GLAND FUNCTION? ... Cancer Thyroid Nodules in Children and Adolescents Thyroid Function Tests Resources Thyroid Function Tests Brochure PDF En ...

  13. Dry blood spot testing for hepatitis C in people who injected drugs: reaching the populations other tests cannot reach.

    Science.gov (United States)

    Tait, J M; Stephens, Brian P; McIntyre, Paul G; Evans, Morgan; Dillon, John F

    2013-10-01

    The aim of the study was to evaluate the effectiveness of Dry Blood Spot testing (DBST) for hepatitis C within a geographical area. This is a prospective cohort study of all individuals living in Tayside who had received a hepatitis C virus (HCV) DBST between 2009 and 2011. During the study, 1123 DBSTs were carried out. 946 individuals had one test. 295 (31.2%) of these individuals were HCV antibody positive on their first test. Overall, 94.3% (902/956) individuals returned for the results of their test. During the course of the study 177 individuals were retested and 29 new cases of hepatitis C were detected. 249 individuals attended for further follow-up, and 164 (65.5%) were PCR positive. All 164 PCR-positive individuals were offered referral into specialist HCV services for further assessment. Data showed 62.5% were genotype 3, 65.1% had a low viral load (<600 000 iu/ml) and 77.5% had a Fibroscan score below 7 KPa. To date, 40 have commenced treatment and a further 16 are currently in the assessment period. Overall, we have retained in services or treated 63.6% (105/164) of patients who were initially referred and with effective support mechanisms in place we have achieved sustained viral response rates of 90%. The study has shown that DBST is a complementary technique to conventional venepuncture for the diagnosis of HCV. The majority of patients have low viral loads and low fibrosis scores, so that while this group of patients may be difficult to reach and may be challenging to maintain in therapy, they are easier to cure.

  14. Association between imagined and actual functional reach (FR): a comparison of young and older adults.

    Science.gov (United States)

    Gabbard, Carl; Cordova, Alberto

    2013-01-01

    Recent studies indicate that the ability to mentally represent action using motor imagery declines with advanced age (>64 years). As the ability to represent action declines, the elderly may experience increasing difficulty with movement planning and execution. Here, we determined the association between estimation of reach via use of motor imagery and actual FR. Young adults (M=22 years) and older adults (M=66 years) estimated reach while standing with targets randomly presented in peripersonal (within actual reach) and extrapersonal (beyond reach) space. Imagined responses were compared to the individual's scaled maximum reach. FR, also while standing, was assessed using the standardized Functional Reach Test (FRT). Results for total score estimation accuracy showed that there was no difference for age; however, results for mean bias and distribution of error revealed that the older group underestimated while the younger group overestimated. In reference to FR, younger adults outperformed older adults (30 versus 14in.) and most prominent, only the younger group showed a significant relationship between estimation and FR. In addition to gaining insight to the effects of advanced age on the ability to mentally represent action and its association with movement execution, these results although preliminary, may have clinical implications based on the question of whether motor imagery training could improve movement estimations and how that might affect actual reach. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  15. Extraocular muscle function testing

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003397.htm Extraocular muscle function testing To use the sharing features on this page, please enable JavaScript. Extraocular muscle function testing examines the function of the eye muscles. ...

  16. Platelet Function Tests

    Science.gov (United States)

    ... Patient Resources For Health Professionals Subscribe Search Platelet Function Tests Send Us Your Feedback Choose Topic At ... Also Known As Platelet Aggregation Studies PFT Platelet Function Assay PFA Formal Name Platelet Function Tests This ...

  17. Kidney function tests

    Science.gov (United States)

    Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...

  18. Liver Function Tests

    Science.gov (United States)

    ... digest food, store energy, and remove poisons. Liver function tests are blood tests that check to see ... as hepatitis and cirrhosis. You may have liver function tests as part of a regular checkup. Or ...

  19. Passive reach and grasp with functional electrical stimulation and robotic arm support

    NARCIS (Netherlands)

    Westerveld, Ard J.; Schouten, Alfred C.; Veltink, Peter H.; van der Kooij, Herman

    2014-01-01

    Rehabilitation of arm and hand function is crucial to increase functional independence of stroke subjects. Here, we investigate the technical feasibility of an integrated training system combining robotics and functional electrical stimulation (FES) to support reach and grasp during functional

  20. A COMPARISON OF THE SIT-AND-REACH TEST AND THE BACK-SAVER SIT-AND-REACH TEST IN UNIVERSITY STUDENTS

    Directory of Open Access Journals (Sweden)

    Pedro A. López-Miñarro

    2009-03-01

    Full Text Available This study compares the forward reach score, spine and pelvis postures, and hamstring criterion-related validity (concurrent validity between the sit-and-reach test (SR and the back-saver sit-and-reach test (BS. Seventy-six men (mean age ± SD: 23.45 ± 3.96 years and 67 women (mean age ± SD: 23.85 ± 5.36 years were asked to perform three trials of SR, BS left (BSl, right (BSr, and passive straight leg raise (PSLR right and left (hamstring criterion measure in a randomized order. The thoracic, lumbar, and pelvis angles (measured with a Uni-level inclinometer and forward reach scores were recorded once the subjects reached forward as far as possible without flexing the knees. A repeated measure ANOVA was performed followed by Bonferroni´s post hoc test. Pearson correlation coefficients were used to define the relationships between SR and BS scores with respect to PSLR. In both men and women, the thoracic angle in BS was significantly greater than in SR (p<0.016. However, no significant differences were found between the tests in lumbar angle, pelvic angle, and forward reach scores. The concurrent validity of the forward reach score as a measure of hamstring extensibility was moderate in women (0.66 0. 76 and weak to moderate in men (0.51 0.59. The concurrent validity was slightly higher in SR than in BS, although no significant differences between the correlation values were observed. There were significant differences in the thoracic angle between the SR and BS, but not in the forward reach score. There was no difference in concurrent validity between the two tests. However, the traditional SR was preferred because it reached better concurrent validity than the BS

  1. Experiences of the REACH testing proposals system to reduce animal testing.

    Science.gov (United States)

    Taylor, Katy; Stengel, Wolfgang; Casalegno, Carlotta; Andrew, David

    2014-01-01

    In order to reduce animal testing, companies registering chemical substances under the EU REACH legislation must propose rather than conduct certain tests on animals. Third parties can submit 'scientifically valid information' relevant to these proposals to the Agency responsible, the European Chemicals Agency (ECHA), who are obliged to take the information into account. The European Coalition to End Animal Experiments (ECEAE) provided comments on nearly half of the 817 proposals for vertebrate tests on 480 substances published for comment for the first REACH deadline (between 1 August 2009 and 31 July 2012). The paper summarises the response by registrants and the Agency to third party comments and highlights issues with the use of read across, in vitro tests, QSAR and weight of evidence approaches. Use of existing data and evidence that testing is legally or scientifically unjustified remain the most successful comments for third parties to submit. There is a worrying conservatism within the Agency regarding the acceptance of alternative approaches and examples of where registrants have also failed to maximise opportunities to avoid testing.

  2. Pancreatic Exocrine Function Testing

    OpenAIRE

    Berk, J. Edward

    1982-01-01

    It is important to understand which pancreatic function tests are available and how to interpret them when evaluating patients with malabsorption. Available direct tests are the secretin stimulation test, the Lundh test meal, and measurement of serum or fecal enzymes. Indirect tests assess pancreatic exocrine function by measuring the effect of pancreatic secretion on various nutrients. These include triglycerides labeled with carbon 14, cobalamin labeled with cobalt 57 and cobalt 58, and par...

  3. Functional Task Test (FTT)

    Science.gov (United States)

    Bloomberg, Jacob J.; Mulavara, Ajitkumar; Peters, Brian T.; Rescheke, Millard F.; Wood, Scott; Lawrence, Emily; Koffman, Igor; Ploutz-Snyder, Lori; Spiering, Barry A.; Feeback, Daniel L.; hide

    2009-01-01

    This slide presentation reviews the Functional Task Test (FTT), an interdisciplinary testing regimen that has been developed to evaluate astronaut postflight functional performance and related physiological changes. The objectives of the project are: (1) to develop a set of functional tasks that represent critical mission tasks for the Constellation Program, (2) determine the ability to perform these tasks after space flight, (3) Identify the key physiological factors that contribute to functional decrements and (4) Use this information to develop targeted countermeasures.

  4. Pancreatic exocrine function testing

    International Nuclear Information System (INIS)

    Goff, J.S.

    1981-01-01

    It is important to understand which pancreatic function tests are available and how to interpret them when evaluating patients with malabsorption. Available direct tests are the secretin stimulation test, the Lundh test meal, and measurement of serum or fecal enzymes. Indirect tests assess pancreatic exocrine function by measuring the effect of pancreatic secretion on various nutrients. These include triglycerides labeled with carbon 14, cobalamin labeled with cobalt 57 and cobalt 58, and para-aminobenzoic acid bound to a dipeptide. Of all these tests the secretin stimulation test is the most accurate and reliable if done by experienced personnel. However, the indirect tests are simpler to do and appear to be comparable to the secretin test at detecting pancreatic exocrine insufficiency. These indirect tests are becoming clinically available and clinicians should familiarize themselves with the strengths and weaknesses of each

  5. Liver Function Tests

    Science.gov (United States)

    ... Liver Function Tests Clinical Trials Liver Transplant FAQs Medical Terminology Diseases of the Liver Alagille Syndrome Alcohol-Related ... the Liver The Progression of Liver Disease FAQs Medical Terminology HOW YOU CAN HELP Sponsorship Ways to Give ...

  6. Automate functional testing

    Directory of Open Access Journals (Sweden)

    Ramesh Kalindri

    2014-06-01

    Full Text Available Currently, software engineers are increasingly turning to the option of automating functional tests, but not always have successful in this endeavor. Reasons range from low planning until over cost in the process. Some principles that can guide teams in automating these tests are described in this article.

  7. Usefulness of the jump-and-reach test in assessment of vertical jump performance.

    Science.gov (United States)

    Menzel, Hans-Joachim; Chagas, Mauro H; Szmuchrowski, Leszek A; Araujo, Silvia R; Campos, Carlos E; Giannetti, Marcus R

    2010-02-01

    The objective was to estimate the reliability and criterion-related validity of the Jump-and-Reach Test for the assessment of squat, countermovement, and drop jump performance of 32 male Brazilian professional volleyball players. Performance of squat, countermovement, and drop jumps with different dropping heights was assessed on the Jump-and-Reach Test and the measurement of flight time, then compared across different jump trials. The very high reliability coefficients of both assessment methods and the lower correlation coefficients between scores on the assessments indicate a very high consistency of each method but only moderate covariation, which means that they measure partly different items. As a consequence, the Jump-and-Reach Test has good ecological validity in situations when reaching height during the flight phase is critical for performance (e.g., basketball and volleyball) but only limited accuracy for the assessment of vertical impulse production with different jump techniques and conditions.

  8. Is there any difference between Back Saver Sit-Reach Test and Modified Back Saver Sit-Reach Test in estimating hamstring flexibility among the primary school children?

    Directory of Open Access Journals (Sweden)

    Bhoomita Gadhiya

    2014-01-01

    Full Text Available Background: Modified back saver sit-and-reach test (MBSSRT has more advantages over Back saver sit-and-reach test (BSSRT in measuring hamstring flexibility among middle school children and adolescents. However, whether MBSSRT can be used instead of the other among the primary school going children is not yet clear. Objective : To estimate the association between BSSRT and MBSSRT for measuring hamstring flexibility. Procedure : One hundred and forty-one healthy children (5-12 years were selected from the primary school identified by the cluster sampling method for this cross-sectional study. The subjects were asked to perform three trials of BSSRT and MBSSRT (both leg in randomized order. Average was used for data analysis. The association between the two tests was established by Spearman Rank Correlation test. Results: The correlation between BSSRT and MBSSRT for right lower limb ranged from 0.43 to 0.77 with mean correlation of ρ = 0.66 (P < 0.01 and for left lower limb ranged from 0.46 to 0.78 with mean correlation of ρ = 0.68 (P < 0.01. Conclusion: MBSSRT can be used alternatively instead of BSSRT to measure hamstring flexibility among the primary school children.

  9. Virtual reality training improves turning capacity and functional reach in stroke patients

    International Nuclear Information System (INIS)

    Malik, A.N.; Masood, T.

    2017-01-01

    Objective: To determine the added effects of virtual reality training on turning capacity, gait parameters and functional reach capacity of stroke patients compared to task oriented training alone. Methodology: A randomized control trial was conducted from February 2016 to July 2106 at Physical Rehabilitation Department Pakistan Railway Hospital, Rawalpindi, Pakistan. Twenty stroke patients were selected through purposive sampling. The patients were randomly assigned through sealed envelope method into two groups; Task Oriented Training (TOT) and Virtual Reality Training (VRT) Group. The standardized tools were used for assessment. The TOT was provided for 4 days per week for 6 weeks while VRT group received additional exer-gaming training during sessions. Results: Significant improvement was observed in both groups regarding reaching forward, turning 360, gait pivot turn (p a 0.01) and FRT (p a 0.001). The two groups were statistically different from each other in terms of turning capacity, reaching forward, gait pivot turn and functional reach after 6 weeks of intervention (p a 0.05) Conclusion: Addition of virtual reality training further improves the significant improvement caused by task oriented training on turning capacity, reaching forward, gait pivot turn and functional reach in stroke patients. (author)

  10. Local tolerance testing under REACH: Accepted non-animal methods are not on equal footing with animal tests.

    Science.gov (United States)

    Sauer, Ursula G; Hill, Erin H; Curren, Rodger D; Raabe, Hans A; Kolle, Susanne N; Teubner, Wera; Mehling, Annette; Landsiedel, Robert

    2016-07-01

    In general, no single non-animal method can cover the complexity of any given animal test. Therefore, fixed sets of in vitro (and in chemico) methods have been combined into testing strategies for skin and eye irritation and skin sensitisation testing, with pre-defined prediction models for substance classification. Many of these methods have been adopted as OECD test guidelines. Various testing strategies have been successfully validated in extensive in-house and inter-laboratory studies, but they have not yet received formal acceptance for substance classification. Therefore, under the European REACH Regulation, data from testing strategies can, in general, only be used in so-called weight-of-evidence approaches. While animal testing data generated under the specific REACH information requirements are per se sufficient, the sufficiency of weight-of-evidence approaches can be questioned under the REACH system, and further animal testing can be required. This constitutes an imbalance between the regulatory acceptance of data from approved non-animal methods and animal tests that is not justified on scientific grounds. To ensure that testing strategies for local tolerance testing truly serve to replace animal testing for the REACH registration 2018 deadline (when the majority of existing chemicals have to be registered), clarity on their regulatory acceptance as complete replacements is urgently required. 2016 FRAME.

  11. Vestibular function testing.

    LENUS (Irish Health Repository)

    Lang, E E

    2010-06-01

    Vestibular symptoms of vertigo, dizziness and dysequilibrium are common complaints which can be disabling both physically and psychologically. Routine examination of the ear nose and throat and neurological system are often normal in these patients. An accurate history and thorough clinical examination can provide a diagnosis in the majority of patients. However, in a subgroup of patients, vestibular function testing may be invaluable in arriving at a correct diagnosis and ultimately in the optimal treatment of these patients.

  12. Cue Salience and Infant Perseverative Reaching: Tests of the Dynamic Field Theory

    Science.gov (United States)

    Clearfield, Melissa W.; Dineva, Evelina; Smith, Linda B.; Diedrich, Frederick J.; Thelen, Esther

    2009-01-01

    Skilled behavior requires a balance between previously successful behaviors and new behaviors appropriate to the present context. We describe a dynamic field model for understanding this balance in infant perseverative reaching. The model predictions are tested with regard to the interaction of two aspects of the typical perseverative reaching…

  13. REACH, non-testing approaches and the urgent need for a change in mind set

    NARCIS (Netherlands)

    Schaafsma, G.; Kroese, E.D.; Tielemans, E.L.J.P.; Sandt, J.J.M. van de; Leeuwen, C.J. van

    2009-01-01

    The objectives of REACH cannot be achieved under the current risk assessment approach. A change in mind set among all the relevant stakeholders is needed: risk assessment should move away from a labor-intensive and animal-consuming approach to intelligent and pragmatic testing, by combining exposure

  14. Local lymph node assay: how testing laboratories apply OECD TG 429 for REACH purposes.

    Science.gov (United States)

    Rovida, Costanza

    2011-01-01

    The Local Lymph Node Assay (LLNA) is the official method for assessing the allergic contact dermatitis potential of chemicals for the purposes of REACH regulation. The LLNA went through a validation process that allowed the delineation of a robust protocol for performing new tests. The OECD accepted this method in 2002 and published OECD TG 429. The European Chemical Agency (ECHA) recently published data that were submitted in the registration dossiers of chemicals. This database was analysed to determine how testing laboratories apply OECD TG 429. This analysis comes after a detailed analysis of four full study reports that were also prepared for REACH purposes. Although the majority of the tests are fully compliant with OECD TG 429, some showed major deviations, and a number of others used more animals than necessary. This suggests that in vivo tests need to be planned more carefully and consciously to obtain meaningful results with the minimum animal number necessary.

  15. Functional Testing Airborne Radars

    Science.gov (United States)

    1981-03-27

    recorded, and presented in accordance with this TOP? Yes No Comment : 2. Were the facilities, test equipment, instrumentation, and support accommo- dations...adequate to accomplish the test objectives? Yes No Comment : 3. Have all data collected been reviewed for correctness and completeness? Yes No ... Comment : 4. Were the test results compromised in any way due to insufficient test planning? Yes No . Comment : 5. Were the test results compromised in any

  16. A comparison of two Shuttle launch and entry suits - Reach envelope, isokinetic strength, and treadmill tests

    Science.gov (United States)

    Schafer, Lauren E.; Rajulu, Sudhakar L.; Klute, Glenn K.

    1992-01-01

    A quantification has been conducted of any existing differences between the performance, in operational conditions, of the Space Shuttle crew Launch Entry Suit (LES) and the new Advanced Crew Escape Suit (ACES). While LES is a partial-pressure suit, the ACES system which is being considered as a replacement for LES is a full-pressure suit. Three tests have been conducted with six subjects to ascertain the suits' reach envelope, strength, and treadmill performance. No significant operational differences were found between the two suit designs.

  17. Testing properties of generic functions

    NARCIS (Netherlands)

    Jansson, P.; Jeuring, J.T.; Cabenda, L.; Engels, G.; Kleerekoper, J.; Mak, S.; Overeem, M.; Visser, Kees

    2006-01-01

    Software testing is an important part of the software devel- opment process. Testing comes in many flavours: unit testing, property testing, regression testing, contract checking, etc. QuickCheck is proba- bly one of the most advanced tools for testing properties of functional programs. It

  18. Contributions of Hamstring Stiffness to Straight-Leg-Raise and Sit-and-Reach Test Scores.

    Science.gov (United States)

    Miyamoto, Naokazu; Hirata, Kosuke; Kimura, Noriko; Miyamoto-Mikami, Eri

    2018-02-01

    The passive straight-leg-raise (PSLR) and the sit-and-reach (SR) tests have been widely used to assess hamstring extensibility. However, it remains unclear to what extent hamstring stiffness (a measure of material properties) contributes to PSLR and SR test scores. Therefore, we aimed to clarify the relationship between hamstring stiffness and PSLR and SR scores using ultrasound shear wave elastography. Ninety-eight healthy subjects completed the study. Each subject completed PSLR testing, and classic and modified SR testing of the right leg. Muscle shear modulus of the biceps femoris, semitendinosus, and semimembranosus was quantified as an index of muscle stiffness. The relationships between shear modulus of each muscle and PSLR or SR scores were calculated using Pearson's product-moment correlation coefficients. Shear modulus of the semitendinosus and semimembranosus showed negative correlations with the two PSLR and two SR scores (absolute r value≤0.484). Shear modulus of the biceps femoris was significantly correlated with the PSLR score determined by the examiner and the modified SR score (absolute r value≤0.308). The present findings suggest that PSLR and SR test scores are strongly influenced by factors other than hamstring stiffness and therefore might not accurately evaluate hamstring stiffness. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Functional connectivity among multi-channel EEGs when working memory load reaches the capacity.

    Science.gov (United States)

    Zhang, Dan; Zhao, Huipo; Bai, Wenwen; Tian, Xin

    2016-01-15

    Evidence from behavioral studies has suggested a capacity existed in working memory. As the concept of functional connectivity has been introduced into neuroscience research in the recent years, the aim of this study is to investigate the functional connectivity in the brain when working memory load reaches the capacity. 32-channel electroencephalographs (EEGs) were recorded for 16 healthy subjects, while they performed a visual working memory task with load 1-6. Individual working memory capacity was calculated according to behavioral results. Short-time Fourier transform was used to determine the principal frequency band (theta band) related to working memory. The functional connectivity among EEGs was measured by the directed transform function (DTF) via spectral Granger causal analysis. The capacity was 4 calculated from the behavioral results. The power was focused in the frontal midline region. The strongest connectivity strengths of EEG theta components from load 1 to 6 distributed in the frontal midline region. The curve of DTF values vs load numbers showed that DTF increased from load 1 to 4, peaked at load 4, then decreased after load 4. This study finds that the functional connectivity between EEGs, described quantitatively by DTF, became less strong when working memory load exceeded the capacity. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. A Rapid Method to Score Stream Reaches Based on the Overall Performance of Their Main Ecological Functions

    Science.gov (United States)

    Rowe, David K.; Parkyn, Stephanie; Quinn, John; Collier, Kevin; Hatton, Chris; Joy, Michael K.; Maxted, John; Moore, Stephen

    2009-06-01

    A method was developed to score the ecological condition of first- to third-order stream reaches in the Auckland region of New Zealand based on the performance of their key ecological functions. Such a method is required by consultants and resource managers to quantify the reduction in ecological condition of a modified stream reach relative to its unmodified state. This is a fundamental precursor for the determination of fair environmental compensation for achieving no-net-loss in overall stream ecological value. Field testing and subsequent use of the method indicated that it provides a useful measure of ecological condition related to the performance of stream ecological functions. It is relatively simple to apply compared to a full ecological study, is quick to use, and allows identification of the degree of impairment of each of the key ecological functions. The scoring system was designed so that future improvements in the measurement of stream functions can be incorporated into it. Although the methodology was specifically designed for Auckland streams, the principles can be readily adapted to other regions and stream types.

  1. Testing properties of generic functions

    NARCIS (Netherlands)

    Jansson, P.; Jeuring, J.T.; Cabenda, L.; Engels, G.; Kleerekoper, J.; Mak, S.; Overeem, M.; Visser, Kees

    2007-01-01

    A datatype-generic function is a family of functions indexed by (the structure of) a type. Examples include equality tests, maps and pretty printers. Property based testing tools like QuickCheck and Gast support the de¯nition of properties and test-data generators, and they check if a

  2. Validity of the Jump-and-Reach Test in Subelite Adolescent Handball Players.

    Science.gov (United States)

    Muehlbauer, Thomas; Pabst, Jan; Granacher, Urs; Büsch, Dirk

    2017-05-01

    Muehlbauer, T, Pabst, J, Granacher, U, and Büsch, D. Validity of the jump-and-reach test in subelite adolescent handball players. J Strength Cond Res 31(5): 1282-1289, 2017-The primary purpose of this study was to examine concurrent validity of the jump-and-reach (JaR) test using the Vertec system and a criterion device (i.e., Optojump system). In separate subanalyses, we investigated the influence of gym floor condition and athletes' sex on the validity of vertical jump height. Four hundred forty subelite adolescent female (n = 222, mean age: 14 ± 1 year, age range: 13-15 years) and male (n = 218, mean age: 15 ± 1 year, age range: 14-16 years) handball players performed the JaR test in gyms with region or point elastic floors. Maximal vertical jump height was simultaneously assessed using the Vertec and the Optojump systems. In general, significantly higher jump heights were obtained for the Vertec compared with the Optojump system (11.2 cm, Δ31%, Cohen's d = 2.58). The subanalyses revealed significantly larger jump heights for the Vertec compared with the Optojump system irrespective of gym floor condition and players' sex. The association between Optojump- and Vertec-derived vertical jump heights amounted to rP = 0.84, with a coefficient of determination (R) of 0.71. The subanalyses indicated significantly larger correlations in males (rP = 0.75, R = 0.56) than in females (rP = 0.63, R = 0.40). Yet, correlations were not significantly different between region (rP = 0.83, R = 0.69) as opposed to point elastic floor (rP = 0.87, R = 0.76). Our findings indicate that the 2 apparatuses cannot be used interchangeably. Consequently, gym floor and sex-specific regression equations were provided to estimate true (Optojump system) vertical jump height from Vertec-derived data.

  3. LUNG FUNCTION TESTING IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Matjaž Fležar

    2004-03-01

    Full Text Available Background. Lung function testing in children above five years old is standardised similarly as is in adult population (1. Nevertheless bronchial provocation testing can be more hazardous since the calibre and reactivity of childhood airway is different. We analysed the frequency of different lung function testing procedures and addressed the safety issues of bronchial provocation testing in children.Methods. We analysed lung function testing results in 517 children, older than 5 years, tested in our laboratory in threeyear period. Spirometry was done in every patient, metacholine provocation test was used as a part of diagnostic work-up in suspected asthma. In case of airway obstruction, bronchodilator test with salbutamol was used instead of a metacholine provocation test.Results. The most common procedure in children was spirometry with bronchial provocation test as a part of diagnostic work-up of obstructive syndrome (mostly asthma. 291 children required metacholine test and 153 tests were interpreted as positive. The decline in expiratory flows (forced expiratory flow in first second – FEV1 in positive tests was greater than in adult population as was the dose of metacholine, needed to induce bronchoconstriction. The compliance of children was better than in adults.Conclusions. Lung function testing in children is reliable and safe and can be done in a well-standardised laboratory that follows the regulations of such testing in adults.

  4. Accuracy and Feasibility of Video Analysis for Assessing Hamstring Flexibility and Validity of the Sit-and-Reach Test

    Science.gov (United States)

    Mier, Constance M.

    2011-01-01

    The accuracy of video analysis of the passive straight-leg raise test (PSLR) and the validity of the sit-and-reach test (SR) were tested in 60 men and women. Computer software measured static hip-joint flexion accurately. High within-session reliability of the PSLR was demonstrated (R greater than 0.97). Test-retest (separate days) reliability for…

  5. Pilot study to test effectiveness of video game on reaching performance in stroke.

    Science.gov (United States)

    Acosta, Ana Maria; Dewald, Hendrik A; Dewald, Jules P A

    2011-01-01

    Robotic systems currently used in upper-limb rehabilitation following stroke rely on some form of visual feedback as part of the intervention program. We evaluated the effect of a video game environment (air hockey) on reaching in stroke with various levels of arm support. We used the Arm Coordination Training 3D system to provide variable arm support and to control the hockey stick. We instructed seven subjects to reach to one of three targets covering the workspace of the impaired arm during the reaching task and to reach as far as possible while playing the video game. The results from this study showed that across subjects, support levels, and targets, the reaching distances achieved with the reaching task were greater than those covered with the video game. This held even after further restricting the mapped workspace of the arm to the area most affected by the flexion synergy (effectively forcing subjects to fight the synergy to reach the hockey puck). The results from this study highlight the importance of designing video games that include specific reaching targets in the workspace compromised by the expression of the flexion synergy. Such video games would also adapt the target location online as a subject's success rate increases.

  6. REPRODUCIBILITY OF THE MODIFIED STAR EXCURSION BALANCE TEST COMPOSITE AND SPECIFIC REACH DIRECTION SCORES.

    Science.gov (United States)

    van Lieshout, Remko; Reijneveld, Elja A E; van den Berg, Sandra M; Haerkens, Gijs M; Koenders, Niek H; de Leeuw, Arina J; van Oorsouw, Roel G; Paap, Davy; Scheffer, Else; Weterings, Stijn; Stukstette, Mirelle J

    2016-06-01

    The mSEBT is a screening tool used to evaluate dynamic balance. Most research investigating measurement properties focused on intrarater reliability and was done in small samples. To know whether the mSEBT is useful to discriminate dynamic balance between persons and to evaluate changes in dynamic balance, more research into intra- and interrater reliability and smallest detectable change (synonymous with minimal detectable change) is needed. To estimate intra- and interrater reliability and smallest detectable change of the mSEBT in adults at risk for ankle sprain. Cross-sectional, test-retest design. Fifty-five healthy young adults participating in sports at risk for ankle sprain participated (mean ± SD age, 24.0 ± 2.9 years). Each participant performed three test sessions within one hour and was rated by two physical therapists (session 1, rater 1; session 2, rater 2; session 3, rater 1). Participants and raters were blinded for previous measurements. Normalized composite and reach direction scores for the right and left leg were collected. Analysis of variance was used to calculate intraclass correlation coefficient values for intra- and interrater reliability. Smallest detectable change values were calculated based on the standard error of measurement. Intra- and interrater reliability for both legs was good to excellent (intraclass correlation coefficient ranging from 0.87 to 0.94). The intrarater smallest detectable change for the composite score of the right leg was 7.2% and for the left 6.2%. The interrater smallest detectable change for the composite score of the right leg was 6.9% and for the left 5.0%. The mSEBT is a reliable measurement instrument to discriminate dynamic balance between persons. Most smallest detectable change values of the mSEBT appear to be large. More research is needed to investigate if the mSEBT is usable for evaluative purposes. Level 2.

  7. VALIDEZ DEL TEST SIT-AND-REACH UNILATERAL COMO CRITERIO DE EXTENSIBILIDAD ISQUIOSURAL. COMPARACIÓN CON OTROS PROTOCOLOS

    Directory of Open Access Journals (Sweden)

    Pedro Ángel López Miñarro

    2008-01-01

    La distancia alcanzada en el sit-and-reach unilateral fue mayor que la obtenida en el sit-and-reach (p<0,001 y en el back-saver sit-and-reach (p<0,001 tanto en hombres como en mujeres. Los valores de correlación del sit-and-reach unilateral con respecto al test de elevación de pierna recta fueron moderados- bajos en varones (r=0,54 y 0,58, respectivamente en la extremidad izquierda y derecha y moderados en mujeres (r=0,73 y 0,75, respec tivamente en la extremidad izquierda y derecha. En conclusión, el test sit-and-reach unilateral presenta una moderada validez como criterio de extensibilidad isquiosural, sobre todo en las mujeres. El test sit-and-reach unilateral es preferible al test back-saver sit-and-reach porque alcanza valores de correlación más elevados con el test de elevación de pierna recta.

  8. Development of microgravity, full body functional reach envelope using 3-D computer graphic models and virtual reality technology

    Science.gov (United States)

    Lindsey, Patricia F.

    1994-01-01

    In microgravity conditions mobility is greatly enhanced and body stability is difficult to achieve. Because of these difficulties, optimum placement and accessibility of objects and controls can be critical to required tasks on board shuttle flights or on the proposed space station. Anthropometric measurement of the maximum reach of occupants of a microgravity environment provide knowledge about maximum functional placement for tasking situations. Calculations for a full body, functional reach envelope for microgravity environments are imperative. To this end, three dimensional computer modeled human figures, providing a method of anthropometric measurement, were used to locate the data points that define the full body, functional reach envelope. Virtual reality technology was utilized to enable an occupant of the microgravity environment to experience movement within the reach envelope while immersed in a simulated microgravity environment.

  9. Learning to reach by reinforcement learning using a receptive field based function approximation approach with continuous actions.

    Science.gov (United States)

    Tamosiunaite, Minija; Asfour, Tamim; Wörgötter, Florentin

    2009-03-01

    Reinforcement learning methods can be used in robotics applications especially for specific target-oriented problems, for example the reward-based recalibration of goal directed actions. To this end still relatively large and continuous state-action spaces need to be efficiently handled. The goal of this paper is, thus, to develop a novel, rather simple method which uses reinforcement learning with function approximation in conjunction with different reward-strategies for solving such problems. For the testing of our method, we use a four degree-of-freedom reaching problem in 3D-space simulated by a two-joint robot arm system with two DOF each. Function approximation is based on 4D, overlapping kernels (receptive fields) and the state-action space contains about 10,000 of these. Different types of reward structures are being compared, for example, reward-on- touching-only against reward-on-approach. Furthermore, forbidden joint configurations are punished. A continuous action space is used. In spite of a rather large number of states and the continuous action space these reward/punishment strategies allow the system to find a good solution usually within about 20 trials. The efficiency of our method demonstrated in this test scenario suggests that it might be possible to use it on a real robot for problems where mixed rewards can be defined in situations where other types of learning might be difficult.

  10. Semen analysis and sperm function tests: How much to test?

    Directory of Open Access Journals (Sweden)

    S S Vasan

    2011-01-01

    Full Text Available Semen analysis as an integral part of infertility investigations is taken as a surrogate measure for male fecundity in clinical andrology, male fertility, and pregnancy risk assessments. Clearly, laboratory seminology is still very much in its infancy. In as much as the creation of a conventional semen profile will always represent the foundations of male fertility evaluation, the 5th edition of the World Health Organization (WHO manual is a definitive statement on how such assessments should be carried out and how the quality should be controlled. A major advance in this new edition of the WHO manual, resolving the most salient critique of previous editions, is the development of the first well-defined reference ranges for semen analysis based on the analysis of over 1900 recent fathers. The methodology used in the assessment of the usual variables in semen analysis is described, as are many of the less common, but very valuable, sperm function tests. Sperm function testing is used to determine if the sperm have the biologic capacity to perform the tasks necessary to reach and fertilize ova and ultimately result in live births. A variety of tests are available to evaluate different aspects of these functions. To accurately use these functional assays, the clinician must understand what the tests measure, what the indications are for the assays, and how to interpret the results to direct further testing or patient management.

  11. [Responses of functional diversity of aquatic insect community to land use change in middle reach of Qiantang River, East China].

    Science.gov (United States)

    Zhang, Lian-Bo; Liu, Dong-Xiao; Liu, Shuo-Ru; Zhang, Yong; Tong, Xiao-Li; Wang, Bei-Xin

    2013-10-01

    Based on the biological traits such as life history, resistance ability against environmental disturbance, and physiological characteristics of aquatic insects, and by using the fourth-corner statistical method, this paper studied the responses of the functional diversity of aquatic insect community to land use change in the middle reach of Qiantang River, Zhejiang Province of East China. For the test aquatic insect community, some of its biological traits were sensitive to land use change, and altered along human disturbance gradients as expected. With the increasing intensity of human disturbance, the maximal insect body length decreased gradually, the dominant respiration pattern evolved from gill respiration to tegument respiration, and the abundance of burrowers increased significantly. At the same time, the functional diversity measured as Rao's quadratic entropy was significantly higher in reference sites than in disturbed sites (P aquatic community were mainly induced by the land use change caused by human activities, which resulted in the decline of stream water quality and habitat quality and the variations of aquatic insect community composition and biological traits. The aquatic insect biological traits and functional diversity could be the potentially effective indicators in the stream health assessment in the future.

  12. Functional tests for myocardial ischemia

    International Nuclear Information System (INIS)

    Levinson, J.R.; Guiney, T.E.; Boucher, C.A.

    1991-01-01

    Functional tests for myocardial ischemia are numerous. Most depend upon a combination of either exercise or pharmacologic intervention with analysis of the electrocardiogram, of regional perfusion with radionuclide imaging, or of regional wall motion with radionuclide imaging or echocardiography. While each test has unique features, especially at the research level, they are generally quite similar in clinical practice, so the clinician is advised to concentrate on one or two in which local expertise is high.22 references

  13. Safety of pulmonary function testing

    DEFF Research Database (Denmark)

    Roberts, Cara; Ward, Simon; Walsted, Emil

    2017-01-01

    BACKGROUND: Pulmonary function testing (PFT) is a key investigation in the evaluation of individuals with respiratory symptoms; however, the safety of routine and specialised PFT testing has not been reported in a large data set. Using patient safety incident (PSI) records, we aimed to assess risk...... was rated using the NHS National Patient Safety Agency and any hospital admission reported. RESULTS: There were 119 PSIs reported from 186 000 PFT; that is, 0.6 PSIs per 1000 tests. Cardiopulmonary PSIs were 3.3 times more likely to occur than non-cardiopulmonary (95% CI 2.17 to 5.12). Syncope was the most...

  14. Adapting the Get Yourself Tested Campaign to Reach Black and Latino Sexual-Minority Youth.

    Science.gov (United States)

    Garbers, Samantha; Friedman, Allison; Martinez, Omar; Scheinmann, Roberta; Bermudez, Dayana; Silva, Manel; Silverman, Jen; Chiasson, Mary Ann

    2016-09-01

    Culturally appropriate efforts are needed to increase sexually transmitted disease (STD) testing and care among Black and Latino sexual-minority youth, who are at high risk for STDs. Get Yourself Tested, a national testing campaign, has demonstrated success among youth, but it has yet to be assessed for relevance or impact among this population. This effort included (1) formative and materials-testing research through focus groups; (2) adaptation of existing Get Yourself Tested campaign materials to be more inclusive of Black and Latino sexual-minority youth; (3) a 3-month campaign in four venues of New York City, promoting STD testing at events and through mobile testing and online and social media platforms; (4) process evaluation of outreach activities; and (5) an outcome evaluation of testing at select campaign venues, using a preexperimental design. During the 3-month campaign period, the number of STD tests conducted at select campaign venues increased from a comparable 3-month baseline period. Although testing uptake through mobile vans remained low in absolute numbers, the van drew a high-prevalence sample, with positivity rates of 26.9% for chlamydia and 11.5% for gonorrhea. This article documents the process and lessons learned from adapting and implementing a local campaign for Black and Latino sexual-minority youth. © 2016 Society for Public Health Education.

  15. Functional Magnetic Resonance Imaging of Goal-Directed Reaching in Children with Autism Spectrum Disorders: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Nicole M. G. Salowitz

    2014-04-01

    Full Text Available An unanswered question concerning the neural basis of autism spectrum disorders (ASD is how sensorimotor deficits in individuals with ASD are related to abnormalities of brain function. We previously described a robotic joystick and video game system that allows us to record functional magnetic resonance images (FMRI while adult humans make goal-directed wrist motions. We anticipated several challenges in extending this approach to studying goal-directed behaviors in children with ASD and in typically developing (TYP children. In particular we were concerned that children with autism may express increased levels of anxiety as compared to typically developing children due to the loud sounds and small enclosed space of the MRI scanner. We also were concerned that both groups of children might become restless during testing, leading to an unacceptable amount of head movement. Here we performed a pilot study evaluating the extent to which autistic and typically developing children exhibit anxiety during our experimental protocol as well as their ability to comply with task instructions. Our experimental controls were successful in minimizing group differences in drop-out due to anxiety. Kinematic performance and head motion also were similar across groups. Both groups of children engaged cortical regions (frontal, parietal, temporal, occipital while making goal-directed movements. In addition, the ASD group exhibited task-related correlations in subcortical regions (cerebellum, thalamus, whereas correlations in the TYP group did not reach statistical significance in subcortical regions. Four distinct regions in frontal cortex showed a significant group difference such that TYP children exhibited positive correlations between the hemodynamic response and movement, whereas children with ASD exhibited negative correlations. These findings demonstrate feasibility of simultaneous application of robotic manipulation and functional imaging to study goal

  16. Testing the distinctiveness of visual imagery and motor imagery in a reach paradigm.

    Science.gov (United States)

    Gabbard, Carl; Ammar, Diala; Cordova, Alberto

    2009-01-01

    We examined the distinctiveness of motor imagery (MI) and visual imagery (VI) in the context of perceived reachability. The aim was to explore the notion that the two visual modes have distinctive processing properties tied to the two-visual-system hypothesis. The experiment included an interference tactic whereby participants completed two tasks at the same time: a visual or motor-interference task combined with a MI or VI-reaching task. We expected increased error would occur when the imaged task and the interference task were matched (e.g., MI with the motor task), suggesting an association based on the assumption that the two tasks were in competition for space on the same processing pathway. Alternatively, if there were no differences, dissociation could be inferred. Significant increases in the number of errors were found when the modalities for the imaged (both MI and VI) task and the interference task were matched. Therefore, it appears that MI and VI in the context of perceived reachability recruit different processing mechanisms.

  17. HIV Testing and Counselling in Colombia: Local Experience on Two Different Recruitment Strategies to Better Reach Low Socioeconomic Status Communities

    Directory of Open Access Journals (Sweden)

    Jaime Galindo-Quintero

    2014-01-01

    Full Text Available HIV testing rates remain very low in Colombia, with only 20% of individuals at risk ever tested. In order to tackle this issue, the Corporacion de Lucha Contra el Sida (CLS has implemented a multidisciplinary, provider-initiated, population-based HIV testing/counselling strategy named BAFI. In this report, we describe the experience of CLS at reaching populations from low socioeconomic backgrounds in 2008-2009. Two different approaches were used: one led by CLS and local health care providers (BAFI-1 and the other by CLS and community leaders (BAFI-2. Both approaches included the following: consented HIV screening test, a demographic questionnaire, self-reported HIV knowledge and behaviour questionnaires, pre- and posttest counselling, confirmatory HIV tests, clinical follow-up, access to comprehensive care and antiretroviral treatment. A total of 2085 individuals were enrolled in BAFI-1 and 363 in BAFI-2. The effectiveness indicators for BAFI-1 and BAFI-2, respectively, were HIV positive-confirmed prevalence = 0.29% and 3.86%, return rate for confirmatory results = 62.5% and 93.7%, return rate for comprehensive care = 83.3% and 92.8%, and ART initiation rate = 20% and 76.9%. Although more people were reached with BAFI-1, the community-led BAFI-2 was more effective at reaching individuals with a higher prevalence of behavioural risk factors for HIV infection.

  18. HIV Testing and Counselling in Colombia: Local Experience on Two Different Recruitment Strategies to Better Reach Low Socioeconomic Status Communities

    Science.gov (United States)

    Galindo-Quintero, Jaime; Mueses-Marin, Hector Fabio; Montaño-Agudelo, David; Pinzón-Fernández, María Virginia; Tello-Bolívar, Inés Constanza; Alvarado-Llano, Beatriz Eugenia; Martinez-Cajas, Jorge Luis

    2014-01-01

    HIV testing rates remain very low in Colombia, with only 20% of individuals at risk ever tested. In order to tackle this issue, the Corporacion de Lucha Contra el Sida (CLS) has implemented a multidisciplinary, provider-initiated, population-based HIV testing/counselling strategy named BAFI. In this report, we describe the experience of CLS at reaching populations from low socioeconomic backgrounds in 2008-2009. Two different approaches were used: one led by CLS and local health care providers (BAFI-1) and the other by CLS and community leaders (BAFI-2). Both approaches included the following: consented HIV screening test, a demographic questionnaire, self-reported HIV knowledge and behaviour questionnaires, pre- and posttest counselling, confirmatory HIV tests, clinical follow-up, access to comprehensive care and antiretroviral treatment. A total of 2085 individuals were enrolled in BAFI-1 and 363 in BAFI-2. The effectiveness indicators for BAFI-1 and BAFI-2, respectively, were HIV positive-confirmed prevalence = 0.29% and 3.86%, return rate for confirmatory results = 62.5% and 93.7%, return rate for comprehensive care = 83.3% and 92.8%, and ART initiation rate = 20% and 76.9%. Although more people were reached with BAFI-1, the community-led BAFI-2 was more effective at reaching individuals with a higher prevalence of behavioural risk factors for HIV infection. PMID:24592330

  19. Functional oral intake and time to reach unrestricted dieting for patients with traumatic brain injury

    DEFF Research Database (Denmark)

    Hansen, T.S.; Engberg, Anders; Larsen, K.

    2008-01-01

    . INTERVENTION: Facial oral tract therapy. MAIN OUTCOME MEASURE: Unrestricted dieting assessed by the Functional Oral Intake Scale (FOIS). RESULTS: We found that 93% of all patients had problems with functional oral intake at admission. Within 126 days of rehabilitation, 64% recovered to unrestricted dieting...... instrument (Wald chi(2)=44.40, Poral intake was found to be very common for patients with severe TBI admitted to a subacute rehabilitation department. For those who recovered during hospital rehabilitation......, return to unrestricted dieting happened within 126 days of rehabilitation. The chance of returning to unrestricted dieting depends on the severity of the brain injury and can be predicted by GCS score, RLAS level, FIM score, and functional oral intake at admission. These results are important when...

  20. Cognitive and kidney function: results from a British birth cohort reaching retirement age.

    Directory of Open Access Journals (Sweden)

    Richard J Silverwood

    Full Text Available Previous studies have found associations between cognitive function and chronic kidney disease. We aimed to explore possible explanations for this association in the Medical Research Council National Survey of Health and Development, a prospective birth cohort representative of the general British population.Cognitive function at age 60-64 years was quantified using five measures (verbal memory, letter search speed and accuracy, simple and choice reaction times and glomerular filtration rate (eGFR at the same age was estimated using cystatin C. The cross-sectional association between cognitive function and eGFR was adjusted for background confounding factors (socioeconomic position, educational attainment, prior cognition, and potential explanations for any remaining association (smoking, diabetes, hypertension, inflammation, obesity.Data on all the analysis variables were available for 1306-1320 study members (depending on cognitive measure. Verbal memory and simple and choice reaction times were strongly associated with eGFR. For example, the lowest quartile of verbal memory corresponded to a 4.1 (95% confidence interval 2.0, 6.2 ml/min/1.73 m(2 lower eGFR relative to the highest quartile. Some of this association was explained by confounding due to socioeconomic factors, but very little of it by prior cognition. Smoking, diabetes, hypertension, inflammation and obesity explained some but not all of the remaining association.These analyses support the notion of a shared pathophysiology of impaired cognitive and kidney function at older age, which precedes clinical disease. The implications of these findings for clinical care and research are important and under-recognised, though further confirmatory studies are required.

  1. Sensorimotor Reorganizations of Arm Kinematics and Postural Strategy for Functional Whole-Body Reaching Movements in Microgravity

    Directory of Open Access Journals (Sweden)

    Thomas Macaluso

    2017-10-01

    Full Text Available Understanding the impact of weightlessness on human behavior during the forthcoming long-term space missions is of critical importance, especially when considering the efficiency of goal-directed movements in these unusual environments. Several studies provided a large set of evidence that gravity is taken into account during the planning stage of arm reaching movements to optimally anticipate its consequence upon the moving limbs. However, less is known about sensorimotor changes required to face weightless environments when individuals have to perform fast and accurate goal-directed actions with whole-body displacement. We thus aimed at characterizing kinematic features of whole-body reaching movements in microgravity, involving high spatiotemporal constraints of execution, to question whether and how humans are able to maintain the performance of a functional behavior in the standards of normogravity execution. Seven participants were asked to reach as fast and as accurately as possible visual targets while standing during microgravity episodes in parabolic flight. Small and large targets were presented either close or far from the participants (requiring, in the latter case, additional whole-body displacement. Results reported that participants successfully performed the reaching task with general temporal features of movement (e.g., movement speed close to land observations. However, our analyses also demonstrated substantial kinematic changes related to the temporal structure of focal movement and the postural strategy to successfully perform -constrained- whole-body reaching movements in microgravity. These immediate reorganizations are likely achieved by rapidly taking into account the absence of gravity in motor preparation and execution (presumably from cues about body limbs unweighting. Specifically, when compared to normogravity, the arm deceleration phase substantially increased. Furthermore, greater whole-body forward displacements

  2. Reflex-based grasping, skilled forelimb reaching, and electrodiagnostic evaluation for comprehensive analysis of functional recovery-The 7-mm rat median nerve gap repair model revisited.

    Science.gov (United States)

    Stößel, Maria; Rehra, Lena; Haastert-Talini, Kirsten

    2017-10-01

    The rat median nerve injury and repair model gets increasingly important for research on novel bioartificial nerve grafts. It allows follow-up evaluation of the recovery of the forepaw functional ability with several sensitive techniques. The reflex-based grasping test, the skilled forelimb reaching staircase test, as well as electrodiagnostic recordings have been described useful in this context. Currently, no standard values exist, however, for comparison or comprehensive correlation of results obtained in each of the three methods after nerve gap repair in adult rats. Here, we bilaterally reconstructed 7-mm median nerve gaps with autologous nerve grafts (ANG) or autologous muscle-in-vein grafts (MVG), respectively. During 8 and 12 weeks of observation, functional recovery of each paw was separately monitored using the grasping test (weekly), the staircase test, and noninvasive electrophysiological recordings from the thenar muscles (both every 4 weeks). Evaluation was completed by histomorphometrical analyses at 8 and 12 weeks postsurgery. The comprehensive evaluation detected a significant difference in the recovery of forepaw functional motor ability between the ANG and MVG groups. The correlation between the different functional tests evaluated precisely displayed the recovery of distinct levels of forepaw functional ability over time. Thus, this multimodal evaluation model represents a valuable preclinical model for peripheral nerve reconstruction approaches.

  3. 14 CFR 35.40 - Functional test.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Functional test. 35.40 Section 35.40... STANDARDS: PROPELLERS Tests and Inspections § 35.40 Functional test. The variable-pitch propeller system must be subjected to the applicable functional tests of this section. The same propeller system used in...

  4. Pulmonary Function Testing in Children

    Science.gov (United States)

    ... breathing test. About 15 minutes after taking the medicine, your child will repeat the breathing test. The results from ... the first test to find out if the medicine has improved your child’s breathing. Why shouldn’t I give my child ...

  5. Reliability of a computer software angle tool for measuring spine and pelvic flexibility during the sit-and-reach test.

    Science.gov (United States)

    Mier, Constance M; Shapiro, Belinda S

    2013-02-01

    The purpose of this study was to determine the reliability of a computer software angle tool that measures thoracic (T), lumbar (L), and pelvic (P) angles as a means of evaluating spine and pelvic flexibility during the sit-and-reach (SR) test. Thirty adults performed the SR twice on separate days. The SR test was captured on video and later analyzed for T, L, and P angles using the computer software angle tool. During the test, 3 markers were placed over T1, T12, and L5 vertebrae to identify T, L, and P angles. Intraclass correlation coefficient (ICC) indicated a very high internal consistency (between trials) for T, L, and P angles (0.95-0.99); thus, the average of trials was used for test-retest (between days) reliability. Mean (±SD) values did not differ between days for T (51.0 ± 14.3 vs. 52.3 ± 16.2°), L (23.9 ± 7.1 vs. 23.0 ± 6.9°), or P (98.4 ± 15.6 vs. 98.3 ± 14.7°) angles. Test-retest reliability (ICC) was high for T (0.96) and P (0.97) angles and moderate for L angle (0.84). Both intrarater and interrater reliabilities were high for T (0.95, 0.94) and P (0.97, 0.97) angles and moderate for L angle (0.87, 0.82). Thus, the computer software angle tool is a highly objective method for assessing spine and pelvic flexibility during a video-captured SR test.

  6. Reaching the hard to reach.

    Science.gov (United States)

    Bhiwandi, P; Campbell, M; Potts, M

    1994-01-01

    The 1994 International Conference on Population and Development proposed increasing contraceptive couple protection from 550 million in 1995 to 880 million in 2015. The task for family planning (FP) programs is to provide access to services for, sometimes, inaccessible rural populations. FP need based on desire for no more children has ranged from under 20% in Senegal to almost 80% in Peru. Socioeconomic development was found not to be a prerequisite for fertility change. Gender inequalities in education and social autonomy must be changed. FP access is very important among women with a disadvantaged background or among women unsure about FP. Bangladesh is a good example of a country with increased contraceptive prevalence despite low income. The rule of thumb is that contraception increases of 15% contribute to a drop in family size of about one child. Program effectiveness is related to a variety of factors: contraceptive availability at many locations, acceptable price of contraception, delivery of the oral contraceptives without prescriptions, and other strategies. FP is a service not a medical treatment. A range of methods must be promoted and available from a range of facilities. Contraceptive use is dependent on the woman's stage in her lifecycle and is dependent on informed choice. Community-based distribution systems are effective, whereas free distribution by poorly-trained field workers is not always very effective because patient payment of all or part of the cost assures quality and freedom of choice. Effective programs for underprivileged groups involve aggressive, easy to manage programs that can be replicated rapidly. FP serves a useful function in depressing maternal mortality among the poor in Africa, who have no access to quality health services. Social marketing is an effective strategy for reaching remote areas. Political will and robust management are necessary commodities.

  7. Feedback error learning controller for functional electrical stimulation assistance in a hybrid robotic system for reaching rehabilitation

    Directory of Open Access Journals (Sweden)

    Francisco Resquín

    2016-07-01

    Full Text Available Hybrid robotic systems represent a novel research field, where functional electrical stimulation (FES is combined with a robotic device for rehabilitation of motor impairment. Under this approach, the design of robust FES controllers still remains an open challenge. In this work, we aimed at developing a learning FES controller to assist in the performance of reaching movements in a simple hybrid robotic system setting. We implemented a Feedback Error Learning (FEL control strategy consisting of a feedback PID controller and a feedforward controller based on a neural network. A passive exoskeleton complemented the FES controller by compensating the effects of gravity. We carried out experiments with healthy subjects to validate the performance of the system. Results show that the FEL control strategy is able to adjust the FES intensity to track the desired trajectory accurately without the need of a previous mathematical model.

  8. Monitoring performance, pituitary-adrenal hormones and mood profiles: how to diagnose non-functional over-reaching in male elite junior soccer players.

    Science.gov (United States)

    Schmikli, Sándor L; de Vries, Wouter R; Brink, Michel S; Backx, Frank Jg

    2012-11-01

    To verify if in male elite junior soccer players a minimum 1-month performance decrease is accompanied by a mood profile and hormone levels typical of non-functional over-reaching (NFOR). A prospective case-control study using a monthly performance monitor with a standardised field test to detect the performance changes. Players with a performance decrease lasting at least 1 month were compared with control players without a performance decrease on mood scores and pre-exercise and postexercise levels of stress hormones. Sporting field and sports medical laboratory. Ninety-four young elite soccer players were monitored during the 2006-2008 seasons. Twenty-one players were invited to the laboratory, seven of whom showed a significant performance decrease. Performance change over time, scores on the profile of mood states and premaximal and postmaximal exercise serum levels of adrenocorticotropic hormone (ACTH), growth hormone (GH) and cortisol. Players with a performance decrease showed psychological and hormonal changes typical of the non-functional state of over-reaching. Scores were higher on depression and anger, whereas the resting GH levels and ACTH levels after maximal exercise were reduced. ACTH and GH were capable of classifying all but one player correctly as either NFOR or control. Performance-related criteria in field tests are capable of identifying players with worsened mood and adaptations of the endocrine system that fit the definition of NFOR. Performance, mood and hormone levels may therefore be considered as valid instruments to diagnose NFOR in young elite soccer players.

  9. Kinetic test of pancreatic exocrine function

    International Nuclear Information System (INIS)

    Sawabu, Norio; Hirose, Shoichiro; Nakazima, Shin; Yoneda, Masao; Nishimura, Keigo

    1975-01-01

    In order to improve the diagnostic evaluation of pancreatic exocrine function, 75 Se-activity in the duodenal aspirate of twenty control subjects and 131 subjects with pancertic and/or gastrointestinal disease was measured following intravenous injection of 75 Se-selenomethionine. Radioactivity in the duodenal aspirate of the control subjects remained low until 80 min. It then rose rapidly and reached a plateau at 115 min. In contrast, radioactivity in the subjects with pancreatic diseases remained low, or rose only slowly throughout the period of collection. Radioactivity of the protein fraction (TCA-precipitable) in the 80 to 130 min. duodenal aspirates showed good separation between controls and subjects with pancreatic disease. The incidence of abnormalities of TCA-precipitable radioactivity in the 80 to 130 min. duodenal aspirates was significantly higher than that of the conventional PS-test parameters in groups with various pancreatic diseases. All of the subjects having an abnormal maximal ratio of TCA-precipitable radioactivity to protein (representing pancreatic enzyme synthesis) showed an abnormal distribution in output of TCA-precipitable radioactivity in 80 to 130 min. collection (representing both enzyme synthesis and excretion). On the other hand, subjects with an abnormal output of TCA-precipitable radioactivity in 80 to 130 min. could be separated into those with normal and abnormal ratios of TCA-precipitable radioactivity, suggesting the presence of two types of disturbance in pancreatic function. In the latter group both synthesis and secretion of enzyme were impaired. In the former group, secretion of enzyme was depressed, although enzyme synthesis was fairly well preserved. (author)

  10. Kinetic test of pancreatic exocrine function

    Energy Technology Data Exchange (ETDEWEB)

    Sawabu, N; Hirose, S; Nakazima, S; Yoneda, M; Nishimura, K [Kanazawa Univ. (Japan). School of Medicine

    1975-01-01

    In order to improve the diagnostic evaluation of pancreatic exocrine function, /sup 75/Se-activity in the duodenal aspirate of twenty control subjects and 131 subjects with pancertic and/or gastrointestinal disease was measured following intravenous injection of /sup 75/Se-selenomethionine. Radioactivity in the duodenal aspirate of the control subjects remained low until 80 min. It then rose rapidly and reached a plateau at 115 min. In contrast, radioactivity in the subjects with pancreatic diseases remained low, or rose only slowly throughout the period of collection. Radioactivity of the protein fraction (TCA-precipitable) in the 80 to 130 min. duodenal aspirates showed good separation between controls and subjects with pancreatic disease. The incidence of abnormalities of TCA-precipitable radioactivity in the 80 to 130 min. duodenal aspirates was significantly higher than that of the conventional PS-test parameters in groups with various pancreatic diseases. All of the subjects having an abnormal maximal ratio of TCA-precipitable radioactivity to protein (representing pancreatic enzyme synthesis) showed an abnormal distribution in output of TCA-precipitable radioactivity in 80 to 130 min. collection (representing both enzyme synthesis and excretion). On the other hand, subjects with an abnormal output of TCA-precipitable radioactivity in 80 to 130 min. could be separated into those with normal and abnormal ratios of TCA-precipitable radioactivity, suggesting the presence of two types of disturbance in pancreatic function. In the latter group both synthesis and secretion of enzyme were impaired. In the former group, secretion of enzyme was depressed, although enzyme synthesis was fairly well preserved.

  11. Reach-scale stream restoration in agricultural streams of southern Minnesota alters structural and functional responses of macroinvertebrates

    Science.gov (United States)

    Dolph, Christine L.; Eggert, Susan L.; Magner, Joe; Ferrington, Leonard C.; Vondracek, Bruce C.

    2015-01-01

    Recent studies suggest that stream restoration at the reach scale may not increase stream biodiversity, raising concerns about the utility of this conservation practice. We examined whether reach-scale restoration in disturbed agricultural streams was associated with changes in macroinvertebrate community structure (total macroinvertebrate taxon richness, total macroinvertebrate density, Ephemeroptera, Plecoptera, Trichoptera [EPT] taxon richness, % abundance of EPT taxa) or secondary production (macroinvertebrate biomass over time). We collected macroinvertebrate samples over the course of 1 y from restored and unrestored reaches of 3 streams in southern Minnesota and used generalized least-square (GLS) models to assess whether measures of community structure were related to reach type, stream site, or sampling month. After accounting for effects of stream site and time, we found no significant difference in total taxon richness or % abundance of EPT taxa between restored and unrestored reaches. However, the number of EPT taxa and macroinvertebrate density were significantly higher in restored than in unrestored reaches. We compared secondary production estimates among study reaches based on 95th-percentile confidence intervals generated via bootstrapping. In each study stream, secondary production was significantly (2–3×) higher in the restored than in the unrestored reach. Higher productivity in the restored reaches was largely a result of the disproportionate success of a few dominant, tolerant taxa. Our findings suggest that reach-scale restoration may have ecological effects that are not detected by measures of total taxon richness alone.

  12. Iterative Evaluation in a Mobile Counseling and Testing Program to Reach People of Color at Risk for HIV--New Strategies Improve Program Acceptability, Effectiveness, and Evaluation Capabilities

    Science.gov (United States)

    Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles

    2011-01-01

    This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program's…

  13. Basic pulmonary function tests in pig farmers

    Directory of Open Access Journals (Sweden)

    Đuričić Slaviša M.

    2004-01-01

    pulmonary function tests are shown in table 2. The values of FEV1 and FVC in each groups were between 92% and 97% of predicted values, and FEV1/FVCx100 was not lower than 82%. There were no differences in the average values of FEV1 (p=0.574 and FEV1 % predicted (p=0.653 between pig farmers and control subjects. Pearson coefficient of correlation and Spearman nonparametric correlation test revealed a high level of correlation of FEV1 values with sex and age and no correlation of pig farming exposure with cigarette smoking as predictor variables (Table 3. The analysis by linear regression method showed that all examined predictor variables had the effect on the value of FEV1 (Table 4. After the elimination of the two least significant predictor variables it was possible to make the equation for prediction of FEV1 values. DISCUSSION In the present study there are no significant alterations in the values of the basic pulmonary function tests in pig farmers. In the majority of previous similar studies the differences in the average values of FEV1 and FVC between pig farmers and control subjects were also not found. However, in some studies the alterations in several more specific lung function parameters were registered. The decreased values of FEV1 during workshift were also found and they are probably connected to the bronchial hyper reactivity registered in many studies in pig farmers. Longer exposure to swine confinement environment caused more decline in FEV1 and FVC and accelerated mean age-related annual decline in FEV1 was observed reaching to 44 ml/yrs more than expected. The correlations between values of FEV, with pig farming exposure and cigarette smoking in this study were not found. However, the analysis by linear regression method showed that all examined predictor variables had the effect on the value of FEV1. In a few previous bronchoscopic, BAL, and sputum studies some signs of inflammation and morphological changes of the respiratory tract were observed. The

  14. Perspectives for tests of neutrino mass generation at the GeV scale. Experimental reach versus theoretical predictions

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, Rasmus W.; Winter, Walter

    2016-11-15

    We discuss the parameter space reach of future experiments searching for heavy neutral leptons (HNLs) at the GeV scale in terms of neutrino mass models with three HNL generations. We focus on two classes of models: Generic assumptions (such as random mass matrices or the Casas-Ibarra parameterization) and flavor symmetry-generated models. We demonstrate that the generic approaches lead to comparable parameter space predictions, which tend to be at least partially within the reach of future experiments. On the other hand, specific flavor symmetry models yield more refined predictions, some of these can be more clearly excluded. We also highlight the importance to measure the flavor-dependent couplings of the HNLs as a model discriminator, and we clarify the impact of assumptions frequently used in the literature to show the parameter space reach for the active-sterile mixings.

  15. Perspectives for tests of neutrino mass generation at the GeV scale. Experimental reach versus theoretical predictions

    International Nuclear Information System (INIS)

    Rasmussen, Rasmus W.; Winter, Walter

    2016-11-01

    We discuss the parameter space reach of future experiments searching for heavy neutral leptons (HNLs) at the GeV scale in terms of neutrino mass models with three HNL generations. We focus on two classes of models: Generic assumptions (such as random mass matrices or the Casas-Ibarra parameterization) and flavor symmetry-generated models. We demonstrate that the generic approaches lead to comparable parameter space predictions, which tend to be at least partially within the reach of future experiments. On the other hand, specific flavor symmetry models yield more refined predictions, some of these can be more clearly excluded. We also highlight the importance to measure the flavor-dependent couplings of the HNLs as a model discriminator, and we clarify the impact of assumptions frequently used in the literature to show the parameter space reach for the active-sterile mixings.

  16. How to interpret liver function tests

    Directory of Open Access Journals (Sweden)

    Christina Levick

    2017-05-01

    Full Text Available Careful interpretation of liver function tests within the clinical context can help elucidate the cause and severity of the underlying pathology. Predominantly raised alkaline phosphatase represents the cholestatic pattern of biliary pathology, whilst predominantly raised alanine aminotransferase and aspartate aminotransferase represent the hepatocellular pattern of hepatocellular pathology. The severity of liver dysfunction or biliary obstruction is reflected in the bilirubin level and the degree of liver synthetic function can also be indicated by the albumin level. Beyond the liver function tests, prothrombin time provides another marker of liver synthetic function and a low platelet count suggests portal hypertension.

  17. Test bank for precalculus functions & graphs

    CERN Document Server

    Kolman, Bernard; Levitan, Michael L

    1984-01-01

    Test Bank for Precalculus: Functions & Graphs is a supplementary material for the text, Precalculus: Functions & Graphs. The book is intended for use by mathematics teachers.The book contains standard tests for each chapter in the textbook. Each set of test focuses on gauging the level of knowledge the student has achieved during the course. The answers for each chapter test and the final exam are found at the end of the book.Mathematics teachers teaching calculus will find the book extremely useful.

  18. Nonparametric tests for equality of psychometric functions.

    Science.gov (United States)

    García-Pérez, Miguel A; Núñez-Antón, Vicente

    2017-12-07

    Many empirical studies measure psychometric functions (curves describing how observers' performance varies with stimulus magnitude) because these functions capture the effects of experimental conditions. To assess these effects, parametric curves are often fitted to the data and comparisons are carried out by testing for equality of mean parameter estimates across conditions. This approach is parametric and, thus, vulnerable to violations of the implied assumptions. Furthermore, testing for equality of means of parameters may be misleading: Psychometric functions may vary meaningfully across conditions on an observer-by-observer basis with no effect on the mean values of the estimated parameters. Alternative approaches to assess equality of psychometric functions per se are thus needed. This paper compares three nonparametric tests that are applicable in all situations of interest: The existing generalized Mantel-Haenszel test, a generalization of the Berry-Mielke test that was developed here, and a split variant of the generalized Mantel-Haenszel test also developed here. Their statistical properties (accuracy and power) are studied via simulation and the results show that all tests are indistinguishable as to accuracy but they differ non-uniformly as to power. Empirical use of the tests is illustrated via analyses of published data sets and practical recommendations are given. The computer code in MATLAB and R to conduct these tests is available as Electronic Supplemental Material.

  19. Summary of functional and performance test procedures

    DEFF Research Database (Denmark)

    Mitzel, Jens; Gülzow, Erich; Friedrich, K. Andreas

    Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition.......Different Test Modules (TM) are defined for the functional and performance characterization of a PEMFC stack. The master document TM2.00 defines requirements and methodology for parameter variation, stability and data acquisition....

  20. Functional and nonfunctional testing of ATM networks

    Science.gov (United States)

    Ricardo, Manuel; Ferreira, M. E. P.; Guimaraes, Francisco E.; Mamede, J.; Henriques, M.; da Silva, Jorge A.; Carrapatoso, E.

    1995-02-01

    ATM network will support new multimedia services that will require new protocols, those services and protocols will need different test strategies and tools. In this paper, the concepts of functional and non-functional testers of ATM networks are discussed, a multimedia service and its requirements are presented and finally, a summary description of an ATM network and of the test tool that will be used to validate it are presented.

  1. RELATIONSHIPS BETWEEN FUNCTIONAL MOVEMENT TESTS AND PERFORMANCE TESTS IN YOUNG ELITE MALE BASKETBALL PLAYERS.

    Science.gov (United States)

    Gonzalo-Skok, Oliver; Serna, Jorge; Rhea, Matthew R; Marín, Pedro J

    2015-10-01

    Sprinting and jumping are two common and important components of high-level sport performance. The weight-bearing dorsiflexion test (WB-DF) and Star Excursion Balance Test (SEBT) are tools developed to identify athletes at risk for lower extremity injury and may be related to running and jumping performance among athletes. The purposes of the present study were: 1) to identify any relationships between functional movement tests (WB-DF and SEBT) and performance tests (jumping, sprinting and changing direction); 2) to examine any relationships between asymmetries in functional movements and performance tests. Descriptive cohort study. Fifteen elite male basketball players (age: 15.4 ± 0.9 years) were assessed during a three-week period to determine the reliability of functional screening tools and performance tests and to examine the relationships between these tests. Relative (intraclass correlation coefficient) and absolute (coefficient of variation) reliability were used to assess the reproducibility of the tests. Significant correlations were detected between certain functional movement tests and performance tests. Both left and right excursion composite scores related to slower performance times in sprint testing, demonstrating that greater dynamic reach relates to decreased quickness and acceleration among these elite basketball athletes. The various relationships between dynamic functional movement testing, speed, and jump performance provide guidance for the strength and conditioning professional when conducting and evaluating data in an effort to improve performance and reduce risk of injury. The results of the present study suggest that these functional and performance tests do not measure the same components of human movement, and could be paired as outcome measures for the clinical and sport assessment of lower extremity function. 2b.

  2. Indications and interpretation of esophageal function testing.

    Science.gov (United States)

    Gyawali, C Prakash; de Bortoli, Nicola; Clarke, John; Marinelli, Carla; Tolone, Salvatore; Roman, Sabine; Savarino, Edoardo

    2018-05-12

    Esophageal symptoms are common, and can arise from mucosal, motor, functional, and neoplastic processes, among others. Judicious use of diagnostic testing can help define the etiology of symptoms and can direct management. Endoscopy, esophageal high-resolution manometry (HRM), ambulatory pH or pH-impedance manometry, and barium radiography are commonly used for esophageal function testing; functional lumen imaging probe is an emerging option. Recent consensus guidelines have provided direction in using test findings toward defining mechanisms of esophageal symptoms. The Chicago Classification describes hierarchical steps in diagnosing esophageal motility disorders. The Lyon Consensus characterizes conclusive evidence on esophageal testing for a diagnosis of gastroesophageal reflux disease (GERD), and establishes a motor classification of GERD. Taking these recent advances into consideration, our discussion focuses primarily on the indications, technique, equipment, and interpretation of esophageal HRM and ambulatory reflux monitoring in the evaluation of esophageal symptoms, and describes indications for alternative esophageal tests. © 2018 New York Academy of Sciences.

  3. Platelet function testing in pediatric patients

    DEFF Research Database (Denmark)

    Hvas, Anne-Mette; Favaloro, Emmanuel J

    2017-01-01

    Introduction: Platelets play a key role in primary hemostasis and are also intricately linked to secondary hemostasis. Investigation of platelet function in children, especially in neonates, is seriously challenged by the volumes required to perform the majority of platelet function tests and due...

  4. Liver Function Tests in Tuberculoid Leprosy

    Directory of Open Access Journals (Sweden)

    R V Korane

    1979-01-01

    Full Text Available A total of 24 patients with untreated tuberculoid leprosy were taken up for study, They were the same group of patients in whom the authors have earlier reported involvement of liver in 85 % cases. Five healthy controls, studied also belonged to the same series. Liver function tests included prothrombin time, serum bilirubin, zinc sulphate turbidity, serum proteins and serum transaminases. No significant alterations in the liver function were observed. This is because the changes in the liver were so minimal and focal that they were not reflected in the various liver function tests.

  5. ELEFUNT, Testing of Elementary Function Subroutines

    International Nuclear Information System (INIS)

    Cody, W.J.

    1981-01-01

    1 - Description of problem or function: ELEFUNT is a FORTRAN test package for the elementary functions. Each program is an aggressive test of one or more of the elementary function subroutines generally supplied with the support library accompanying a FORTRAN compiler. Functions tested are ALOG/ALOG10, ASIN/ACOS, ATAN, EXP, POWER, SIN/ COS, SINH/COSH, SQRT, TAN/COTAN, and TANH. 2 - Method of solution: The programs check the accuracy of the functions by using purified random arguments from appropriate intervals in carefully selected identities. They also check special properties of each function, test for the handling of special arguments, and exercise the error returns. 3 - Restrictions on the complexity of the problem: The package contains one subroutine (MACHAR) for dynamic determination of parameters describing the floating-point arithmetic system of the host machine, the test programs must be modified to insert the necessary machine- dependent parameters in DATA statements, or otherwise make them available. This computing environment inquiry routine is known to malfunction when the arithmetic registers are wider than the storage registers

  6. Inside anesthesia breathing circuits: time to reach a set sevoflurane concentration in toddlers and newborns: simulation using a test lung.

    Science.gov (United States)

    Kern, Delphine; Larcher, Claire; Basset, Bertrand; Alacoque, Xavier; Fesseau, Rose; Samii, Kamran; Minville, Vincent; Fourcade, Olivier

    2012-08-01

    We measured the time it takes to reach the desired inspired anesthetic concentration using the Primus (Drägerwerk, AG, Lübeck, Germany) and the Avance (GE Datex-Ohmeda, Munich, Germany) anesthesia machines with toddler and newborn ventilation settings. The time to reach 95% of inspired target sevoflurane concentration was measured during wash-in from 0 to 6 vol% sevoflurane and during wash-out from 6 to 0 vol% with fresh gas flows equal to 1 and 2 times the minute ventilation. The Avance was faster than the Primus (65 seconds [95% confidence interval (CI): 55 to 78] vs 310 seconds [95% CI: 261 to 359]) at 1.5 L/min fresh gas flow, tidal volume of 50 mL, and 30 breaths/min. Times were shorter by the same magnitude at higher fresh gas flows and higher minute ventilation rates. The effect of doubling fresh gas flow was variable and less than expected. The Primus is slower during newborn than toddler ventilation, whereas the Avance's response time was the same for newborn and toddler ventilation. Our data confirm that the time to reach the target-inspired anesthetic concentration depends on breathing circuit volume, fresh gas flow, and minute ventilation.

  7. Quantum algorithms for testing Boolean functions

    Directory of Open Access Journals (Sweden)

    Erika Andersson

    2010-06-01

    Full Text Available We discuss quantum algorithms, based on the Bernstein-Vazirani algorithm, for finding which variables a Boolean function depends on. There are 2^n possible linear Boolean functions of n variables; given a linear Boolean function, the Bernstein-Vazirani quantum algorithm can deterministically identify which one of these Boolean functions we are given using just one single function query. The same quantum algorithm can also be used to learn which input variables other types of Boolean functions depend on, with a success probability that depends on the form of the Boolean function that is tested, but does not depend on the total number of input variables. We also outline a procedure to futher amplify the success probability, based on another quantum algorithm, the Grover search.

  8. Effects of modified constraint-induced movement therapy on reach-to-grasp movements and functional performance after chronic stroke: a randomized controlled study.

    Science.gov (United States)

    Lin, K-C; Wu, C-Y; Wei, T-H; Lee, C-Y; Liu, J-S

    2007-12-01

    To evaluate changes in (1) motor control characteristics of the hemiparetic hand during the performance of a functional reach-to-grasp task and (2) functional performance of daily activities in patients with stroke treated with modified constraint-induced movement therapy. Two-group randomized controlled trial with pretreatment and posttreatment measures. Rehabilitation clinics. Thirty-two chronic stroke patients (21 men, 11 women; mean age=57.9 years, range=43-81 years) 13-26 months (mean 16.3 months) after onset of a first-ever cerebrovascular accident. Thirty-two patients were randomized to receive modified constraint-induced movement therapy (restraint of the unaffected limb combined with intensive training of the affected limb) or traditional rehabilitation for three weeks. Kinematic analysis was used to assess motor control characteristics as patients reached to grasp a beverage can. Functional outcomes were evaluated using the Motor Activity Log and Functional Independence Measure. There were moderate and significant effects of modified constraint-induced movement therapy on some aspects of motor control of reach-to-grasp and on functional ability. The modified constraint-induced movement therapy group preplanned reaching and grasping (P=0.018) more efficiently and depended more on the feedforward control of reaching (P=0.046) than did the traditional rehabilitation group. The modified constraint-induced movement therapy group also showed significantly improved functional performance on the Motor Activity Log (Pcontrol strategy during goal-directed reaching, a possible mechanism for the improved movement performance of stroke patients undergoing this therapy.

  9. CIT photoheliograph functional verification unit test program

    Science.gov (United States)

    1973-01-01

    Tests of the 2/3-meter photoheliograph functional verification unit FVU were performed with the FVU installed in its Big Bear Solar Observatory vacuum chamber. Interferometric tests were run both in Newtonian (f/3.85) and Gregorian (f/50) configurations. Tests were run in both configurations with optical axis horizontal, vertical, and at 45 deg to attempt to determine any gravity effects on the system. Gravity effects, if present, were masked by scatter in the data associated with the system wavefront error of 0.16 lambda rms ( = 6328A) apparently due to problems in the primary mirror. Tests showed that the redesigned secondary mirror assembly works well.

  10. Functional Testing of Wireless Sensor Node Designs

    DEFF Research Database (Denmark)

    Virk, Kashif M.; Madsen, Jan

    2007-01-01

    Wireless sensor networks are networked embedded computer systems with stringent power, performance, cost and form-factor requirements along with numerous other constraints related to their pervasiveness and ubiquitousness. Therefore, only a systematic design methdology coupled with an efficient...... test approach can enable their conformance to design and deployment specifications. We discuss off-line, hierarchical, functional testing of complete wireless sensor nodes containing configurable logic through a combination of FPGA-based board test and Software-Based Self-Test (SBST) techniques...

  11. Y BALANCE TEST™ ANTERIOR REACH SYMMETRY AT THREE MONTHS IS RELATED TO SINGLE LEG FUNCTIONAL PERFORMANCE AT TIME OF RETURN TO SPORTS FOLLOWING ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION.

    Science.gov (United States)

    Garrison, J Craig; Bothwell, James M; Wolf, Gina; Aryal, Subhash; Thigpen, Charles A

    2015-10-01

    Restoration of symmetrical strength, balance, and power following anterior cruciate ligament reconstruction (ACL-R) are thought to be important factors for successful return to sports. Little information is available regarding early rehabilitation outcomes and achieving suggested limb indices of 90% on functional performance measures at the time of return to sports (RTS). To examine the relationship between symmetry of the anterior reach of the Y Balance Test™ at 12 weeks and functional performance measures at time of return to sports after anterior cruciate ligament (ACL) reconstruction. Retrospective Cohort. Forty subjects (mean ± SD age, 17.2 ± 3.8 years) who were in the process of rehabilitation following ACL reconstruction. Each subject volunteered and was enrolled in the study during physical therapy following ACL-R. Participants averaged two visits per week in physical therapy until the time of testing for RTS. The Y Balance Test™ was assessed at 12 weeks. Participants completed a battery of tests at RTS (6.4 ± 1.1 months) including triple hop distance (THD), single hop distance (SHD), isometric knee extension strength (KE), and the Vail Sport Test™. Side to side difference was calculated for the Y Balance Test™ anterior reach and limb symmetry indices (LSI) were computed for THD, SHD, and KE. Multiple regression models were used to study the relationship between variables at 12 weeks and RTS while controlling for age, gender, type of graft, and pain score. In addition, subjects were dichotomized based on a side-to-side Y Balance anterior reach difference into high risk (>4 cm) or low risk (≤4 cm) categories. A receiver operating characteristic (ROC) curve was used to identify individuals at 12 weeks who do not achieve 90% limb symmetry indices at time of RTS testing. . A statistically significant association was seen between Y Balance ANT at 12 weeks and SHD at RTS (β = -1.46, p = 0.0005, R(2) = 0.395), THD at RTS

  12. Esophageal function testing: Billing and coding update.

    Science.gov (United States)

    Khan, A; Massey, B; Rao, S; Pandolfino, J

    2018-01-01

    Esophageal function testing is being increasingly utilized in diagnosis and management of esophageal disorders. There have been several recent technological advances in the field to allow practitioners the ability to more accurately assess and treat such conditions, but there has been a relative lack of education in the literature regarding the associated Common Procedural Terminology (CPT) codes and methods of reimbursement. This review, commissioned and supported by the American Neurogastroenterology and Motility Society Council, aims to summarize each of the CPT codes for esophageal function testing and show the trends of associated reimbursement, as well as recommend coding methods in a practical context. We also aim to encourage many of these codes to be reviewed on a gastrointestinal (GI) societal level, by providing evidence of both discrepancies in coding definitions and inadequate reimbursement in this new era of esophageal function testing. © 2017 John Wiley & Sons Ltd.

  13. Request of thyroid function tests from Primary Care in Spain.

    Science.gov (United States)

    Salinas, Maria; López-Garrigós, Maite; Pomares, Francisco J; Flores, Emilio; Uris, Joaquín; Leiva-Salinas, Carlos

    2016-01-01

    Laboratory tests are crucial for diagnosis and monitoring of thyroid disorders. It is therefore necessary to study the pattern and variability in requests of thyroid function tests. The study objectives were to compare the inter-regional variability in the request of laboratory thyroid tests by general practitioners (GPs) in Spain, and to investigate the potential economic savings if the goals set for some suitability indicators were reached. Test requests per 1,000 inhabitants and test ratios (free thyroxine (FT4)/thyrotropin (TSH), free triiodothyronine (FT3)/TSH, thyroglobulin antibody (TgAb)/peroxidase antibody (TPOAb)) were compared between the different areas, according to their setting, location, and management. The resulting savings if each department achieved the goals for indicator (0.25 for FT4/TSH, 0.1 for FT3/TSH) were estimated. Seventy-six laboratories covering a population of 17,679,195 inhabitants participated in the study. TSH was requested significantly less in urban-rural areas, and the requests for FT3/1,000 inhabitants, FT3/TSH, and TgAb/TPOAb were higher in departments with private management. The savings generated if specifications for the ratios of related tests were met would be 937,260.5 €. The high variability reported in requests for thyroid function and autoimmunity tests in Spain suggests the need for implementing strategies to improve use of such tests. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  14. An automated system for pulmonary function testing

    Science.gov (United States)

    Mauldin, D. G.

    1974-01-01

    An experiment to quantitate pulmonary function was accepted for the space shuttle concept verification test. The single breath maneuver and the nitrogen washout are combined to reduce the test time. Parameters are defined from the forced vital capacity maneuvers. A spirometer measures the breath volume and a magnetic section mass spectrometer provides definition of gas composition. Mass spectrometer and spirometer data are analyzed by a PDP-81 digital computer.

  15. Monitoring performance, pituitary-adrenal hormones and mood profiles : how to diagnose non-functional over-reaching in male elite junior soccer players

    NARCIS (Netherlands)

    Schmikli, Sandor L.; de Vries, Wouter R.; Brink, Michel S.; Backx, Frank J. G.

    2012-01-01

    Objective To verify if in male elite junior soccer players a minimum 1-month performance decrease is accompanied by a mood profile and hormone levels typical of non-functional over-reaching (NFOR). Design A prospective case-control study using a monthly performance monitor with a standardised field

  16. Pulmonary function testing in children and infants

    International Nuclear Information System (INIS)

    Vogt, B; Weiler, N; Frerichs, I; Falkenberg, C

    2014-01-01

    Pulmonary function testing is performed in children and infants with the aim of documenting lung development with age and making diagnoses of lung diseases. In children and infants with an established lung disease, pulmonary function is tested to assess the disease progression and the efficacy of therapy. It is difficult to carry out the measurements in this age group without disturbances, so obtaining results of good quality and reproducibility is challenging. Young children are often uncooperative during the examinations. This is partly related to their young age but also due to the long testing duration and the unpopular equipment. We address a variety of examination techniques for lung function assessment in children and infants in this review. We describe the measuring principles, examination procedures, clinical findings and their interpretation, as well as advantages and limitations of these methods. The comparability between devices and centres as well as the availability of reference values are still considered a challenge in many of these techniques. In recent years, new technologies have emerged allowing the assessment of lung function not only on the global level but also on the regional level. This opens new possibilities for detecting regional lung function heterogeneity that might lead to a better understanding of respiratory pathophysiology in children. (topical review)

  17. Gas Test Loop Functional and Technical Requirements

    International Nuclear Information System (INIS)

    Glen R. Longhurst; Soli T. Khericha; James L. Jones

    2004-01-01

    This document defines the technical and functional requirements for a gas test loop (GTL) to be constructed for the purpose of providing a high intensity fast-flux irradiation environment for developers of advanced concept nuclear reactors. This capability is needed to meet fuels and materials testing requirements of the designers of Generation IV (GEN IV) reactors and other programs within the purview of the Advanced Fuel Cycle Initiative (AFCI). Space nuclear power development programs may also benefit by the services the GTL will offer. The overall GTL technical objective is to provide developers with the means for investigating and qualifying fuels and materials needed for advanced reactor concepts. The testing environment includes a fast-flux neutron spectrum of sufficient intensity to perform accelerated irradiation testing. Appropriate irradiation temperature, gaseous environment, test volume, diagnostics, and access and handling features are also needed. This document serves to identify those requirements as well as generic requirements applicable to any system of this kind

  18. Gas Test Loop Functional and Technical Requirements

    Energy Technology Data Exchange (ETDEWEB)

    Glen R. Longhurst; Soli T. Khericha; James L. Jones

    2004-09-01

    This document defines the technical and functional requirements for a gas test loop (GTL) to be constructed for the purpose of providing a high intensity fast-flux irradiation environment for developers of advanced concept nuclear reactors. This capability is needed to meet fuels and materials testing requirements of the designers of Generation IV (GEN IV) reactors and other programs within the purview of the Advanced Fuel Cycle Initiative (AFCI). Space nuclear power development programs may also benefit by the services the GTL will offer. The overall GTL technical objective is to provide developers with the means for investigating and qualifying fuels and materials needed for advanced reactor concepts. The testing environment includes a fast-flux neutron spectrum of sufficient intensity to perform accelerated irradiation testing. Appropriate irradiation temperature, gaseous environment, test volume, diagnostics, and access and handling features are also needed. This document serves to identify those requirements as well as generic requirements applicable to any system of this kind.

  19. Proposal of how to update the standard information requirements in REACH, PPPR and BPR – a testing strategy for identification of endocrine disruptors

    DEFF Research Database (Denmark)

    Holbech, Henrik; Bjerregaard, Poul; Hass, Ulla

    to these, new test methods that include endocrine sensitive endpoints have been included with regard to human health and the environment. Similar data requirements and new test methods that include endocrine sensitive endpoints are included in the guidance on Regulation (EU) No 528/2012 on how to fulfil...... review on EDs and the revised strategy for the future work on endocrine disruptors, focusing on adequate detection of substances with endocrine disrupting properties under various legislative frameworks, including REACH (EC No 1907/2006), the Plant Protection Products Regulation (PPPR) (EC No 1107....../2009) and the Biocidal Products Regulation (BPR) (EC No 528/2012). There are currently no specific information requirements or testing strategies with regard to endocrine disruption in REACH and other relevant legislations. However, in relation to biocides and recently also to plant protection products, indications...

  20. Do functional tests predict low back pain?

    Science.gov (United States)

    Takala, E P; Viikari-Juntura, E

    2000-08-15

    A cohort of 307 nonsymptomatic workers and another cohort of 123 workers with previous episodes of low back pain were followed up for 2 years. The outcomes were measured by symptoms, medical consultations, and sick leaves due to low back disorders. To study the predictive value of a set of tests measuring the physical performance of the back in a working population. The hypothesis was that subjects with poor functional capacity are liable to back disorders. Reduced functional performance has been associated with back pain. There are few data to show whether reduced functional capacity is a cause or a consequence of pain. Mobility of the trunk in forward and side bending, maximal isokinetic trunk extension, flexion and lifting strength, and static endurance of back extension were measured. Standing balance and foot reaction time were recorded with a force plate. Clinical tests for the provocation of back or leg pain were performed. Gender, workload, age, and anthropometrics were managed as potential confounders in the analysis. Marked overlapping was seen in the measures of the subjects with different outcomes. Among the nonsymptomatic subjects, low performance in tests of mobility and standing balance was associated with future back disorders. Among workers with previous episodes of back pain, low isokinetic extension strength, poor standing balance, and positive clinical signs predicted future pain. Some associations were found between the functional tests and future low back pain. The wide variation in the results questions the value of the tests in health examinations (e.g., in screening or surveillance of low back disorders).

  1. The effects of donor stage on the survival and function of embryonic striatal grafts in the adult rat brain; II. Correlation between positron emission tomography and reaching behaviour

    International Nuclear Information System (INIS)

    Dunnett, S.B.; Brooks, D.J.; Ashworth, S.; Opacka-Juffrey, J.; Myers, R.; Hume, S.P.; Torres, E.M.; Fricker, R.A.

    1997-01-01

    Grafts of embryonic striatal primordia are able to elicit behavioural recovery in rats which have received an excitotoxic lesion to the striatum, and it is believed that the P zones or striatal-like tissue within the transplants play a crucial role in these functional effects. We performed this study to compare the effects of different donor stage of embryonic tissue on both the morphology (see accompanying paper) and function of striatal transplants. Both the medial and lateral ganglionic eminence was dissected from rat embryos of either 10 mm, 15 mm, 19 mm, or 23 mm crown-rump length, and implanted as a cell suspension into adult rats which had received an ibotenic acid lesion 10 days prior to transplantation. After four months the animals were tested on the 'staircase task' of skilled forelimb use. At 10-14 months rats from the groups which had received grafts from 10 mm or 15 mm donor embryos were taken for positron emission tomography scanning in a small diameter postiron emission tomography scanner, using ligands to the dopamine D 1 and D 2 receptors, [ 11 C]SCH 23390 and [ 11 C]raclopride, respectively. A lesion-alone group was also scanned with the same ligands for comparison. Animals which had received transplants from the 10 mm donors showed a significant recovery with their contralateral paw on the 'staircase test'. No other groups showed recovery on this task. Similarly, the animals with grafts from the youngest donors showed a significant increase in D 1 and D 2 receptor binding when compared to the lesion-alone group. No increase in signal was observed with either ligand in the group which had received grafts from 15 mm donors. Success in paw reaching showed a strong correlation to both the positron emission tomography signal obtained and the P zone volume of the grafts.These results suggest that striatal grafts from younger donors (10 mm CRL) give greater behavioural recovery than grafts prepared from older embryos. This recovery is due to both the

  2. The Use of Functional Electrical Stimulation on the Upper Limb and Interscapular Muscles of Patients with Stroke for the Improvement of Reaching Movements: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Alicia Cuesta-Gómez

    2017-05-01

    Full Text Available IntroductionReaching movements in stroke patients are characterized by decreased amplitudes at the shoulder and elbow joints and greater displacements of the trunk, compared to healthy subjects. The importance of an appropriate and specific contraction of the interscapular and upper limb (UL muscles is crucial to achieving proper reaching movements. Functional electrical stimulation (FES is used to activate the paretic muscles using short-duration electrical pulses.ObjectiveTo evaluate whether the application of FES in the UL and interscapular muscles of stroke patients with motor impairments of the UL modifies patients’ reaching patterns, measured using instrumental movement analysis systems.DesignA cross-sectional study was carried out.SettingThe VICON Motion System® was used to conduct motion analysis.ParticipantsTwenty-one patients with chronic stroke.InterventionThe Compex® electric stimulator was used to provide muscle stimulation during two conditions: a placebo condition and a FES condition.Main outcome measuresWe analyzed the joint kinematics (trunk, shoulder, and elbow from the starting position until the affected hand reached the glass.ResultsParticipants receiving FES carried out the movement with less trunk flexion, while shoulder flexion elbow extension was increased, compared to placebo conditions.ConclusionThe application of FES to the UL and interscapular muscles of stroke patients with motor impairment of the UL has improved reaching movements.

  3. ITERATIVE EVALUATION IN A MOBILE COUNSELING AND TESTING PROGRAM TO REACH PEOPLE OF COLOR AT RISK FOR HIV—NEW STRATEGIES IMPROVE PROGRAM ACCEPTABILITY, EFFECTIVENESS, AND EVALUATION CAPABILITIES

    Science.gov (United States)

    Spielberg, Freya; Kurth, Ann; Reidy, William; McKnight, Teka; Dikobe, Wame; Wilson, Charles

    2016-01-01

    This article highlights findings from an evaluation that explored the impact of mobile versus clinic-based testing, rapid versus central-lab based testing, incentives for testing, and the use of a computer counseling program to guide counseling and automate evaluation in a mobile program reaching people of color at risk for HIV. The program’s results show that an increased focus on mobile outreach using rapid testing, incentives and health information technology tools may improve program acceptability, quality, productivity and timeliness of reports. This article describes program design decisions based on continuous quality assessment efforts. It also examines the impact of the Computer Assessment and Risk Reduction Education computer tool on HIV testing rates, staff perception of counseling quality, program productivity, and on the timeliness of evaluation reports. The article concludes with a discussion of implications for programmatic responses to the Centers for Disease Control and Prevention’s HIV testing recommendations. PMID:21689041

  4. The EORTC emotional functioning computerized adaptive test

    DEFF Research Database (Denmark)

    Gamper, Eva-Maria; Grønvold, Mogens; Petersen, Morten Aa

    2014-01-01

    The European Organisation for Research and Treatment of Cancer (EORTC) Quality of Life Group is currently developing computerized adaptive testing measures for the Quality of Life Questionnaire Core-30 (QLQ-C30) scales. The work presented here describes the development of an EORTC item bank for e...... for emotional functioning (EF), which is one of the core domains of the QLQ-C30....

  5. Update on endoscopic pancreatic function testing

    Institute of Scientific and Technical Information of China (English)

    Tyler Stevens; Mansour A Parsi

    2011-01-01

    Hormone-stimulated pancreatic function tests (PFTs) are considered the gold standard for measuring pancreatic exocrine function. PFTs involve the administration of intravenous secretin or cholecystokinin, followed by collection and analysis of pancreatic secretions. Because exocrine function may decline in the earliest phase of pancreatic fibrosis, PFTs are considered accurate for diagnosing chronic pancreatitis. Unfortunately, these potentially valuable tests are infrequently performed except at specialized centers, because they are time consuming and complicated. To overcome these limitations, endoscopic PFT methods have been developed which include aspiration of pancreatic secretions through the suction channel of the endoscope. The secretin endoscopic pancreatic function test (ePFT) involves collection of duodenal aspirates at 15, 30, 45 and 60 min after secretin stimulation. A bicarbonate concentration greater than 80 mmol/L in any of the samples is considered a normal result. The secretin ePFT has demonstrated good sensitivity and specificity compared with various reference standards, including the "Dreiling tube" secretin PFT, endoscopic ultrasound, and surgical histology. Furthermore, a standard autoanalyzer can be used for bicarbonate analysis, which allows the secretin ePFT to be performed at any hospital. The secretin ePFT may complement imaging tests like endoscopic ultrasound (EUS) in the diagnosis of early chronic pancreatitis.This paper will review the literature validating the use of ePFT in the diagnosis of exocrine insufficiency and chronic pancreatitis. Newer developments will also be discussed, including the feasibility of combined EUS/ePFT, the use of cholecystokinin alone or in combination with secretin, and the discovery of new protein and lipid pancreatic juice biomarkers which may complement traditionalfluid analysis.

  6. Expanding the Reach of Participatory Risk Management: Testing an Online Decision-Aiding Framework for Informing Internally Consistent Choices.

    Science.gov (United States)

    Bessette, Douglas L; Campbell-Arvai, Victoria; Arvai, Joseph

    2016-05-01

    This article presents research aimed at developing and testing an online, multistakeholder decision-aiding framework for informing multiattribute risk management choices associated with energy development and climate change. The framework was designed to provide necessary background information and facilitate internally consistent choices, or choices that are in line with users' prioritized objectives. In order to test different components of the decision-aiding framework, a six-part, 2 × 2 × 2 factorial experiment was conducted, yielding eight treatment scenarios. The three factors included: (1) whether or not users could construct their own alternatives; (2) the level of detail regarding the composition of alternatives users would evaluate; and (3) the way in which a final choice between users' own constructed (or highest-ranked) portfolio and an internally consistent portfolio was presented. Participants' self-reports revealed the framework was easy to use and providing an opportunity to develop one's own risk-management alternatives (Factor 1) led to the highest knowledge gains. Empirical measures showed the internal consistency of users' decisions across all treatments to be lower than expected and confirmed that providing information about alternatives' composition (Factor 2) resulted in the least internally consistent choices. At the same time, those users who did not develop their own alternatives and were not shown detailed information about the composition of alternatives believed their choices to be the most internally consistent. These results raise concerns about how the amount of information provided and the ability to construct alternatives may inversely affect users' real and perceived internal consistency. © 2015 Society for Risk Analysis.

  7. A test for measuring gustatory function.

    Science.gov (United States)

    Smutzer, Gregory; Lam, Si; Hastings, Lloyd; Desai, Hetvi; Abarintos, Ray A; Sobel, Marc; Sayed, Nabil

    2008-08-01

    The purpose of this study was to determine the usefulness of edible taste strips for measuring human gustatory function. The physical properties of edible taste strips were examined to determine their potential for delivering threshold and suprathreshold amounts of taste stimuli to the oral cavity. Taste strips were then assayed by fluorescence to analyze the uniformity and distribution of bitter tastant in the strips. Finally, taste recognition thresholds for sweet taste were examined to determine whether or not taste strips could detect recognition thresholds that were equal to or better than those obtained from aqueous tests. Edible strips were prepared from pullulan-hydroxypropyl methylcellulose solutions that were dried to a thin film. The maximal amount of a tastant that could be incorporated in a 2.54 cm2 taste strip was identified by including representative taste stimuli for each class of tastant (sweet, sour, salty, bitter, and umami) during strip formation. Distribution of the bitter tastant quinine hydrochloride in taste strips was assayed by fluorescence emission spectroscopy. The efficacy of taste strips for evaluating human gustatory function was examined by using a single series ascending method of limits protocol. Sucrose taste recognition threshold data from edible strips was then compared with results that were obtained from a standard "sip and spit" recognition threshold test. Edible films that formed from a pullulan-hydroxypropyl methylcellulose polymer mixture can be used to prepare clear, thin strips that have essentially no background taste and leave no physical presence after release of tastant. Edible taste strips could uniformly incorporate up to 5% of their composition as tastant. Taste recognition thresholds for sweet taste were over one order of magnitude lower with edible taste strips when compared with an aqueous taste test. Edible taste strips are a highly sensitive method for examining taste recognition thresholds in humans. This

  8. Water chemistry management during hot functional test

    International Nuclear Information System (INIS)

    Yokoyama, Jiro; Kanda, Tomio; Kagawa, Masaru

    1988-01-01

    To reduce radiation exposure in light water reactor, it is important decrease radioactive corrosion product which is a radiation source. One of the countermeasures is to improve water quality during plant trial operation to form a stable oxide film and to minimize metal release to the coolant at the beginning of commercial operation. This study reviews the optimum water quality conditions to form a chromium rich oxide film during hot functional test (HFT) that is thought to be stable under the PWR condition and reduce the release of Ni that is the source of Co-58, the main radiation source of exposure. (author)

  9. Integrated Locomotor Function Tests for Countermeasure Evaluation

    Science.gov (United States)

    Bloomberg, J. J.; Mulavara, A. P.; Peters, B. T.; Cohen, H. S.; Landsness, E. C.; Black, F. O.

    2005-01-01

    Following spaceflight crewmembers experience locomotor dysfunction due to inflight adaptive alterations in sensorimotor function. Countermeasures designed to mitigate these postflight gait alterations need to be assessed with a new generation of tests that evaluate the interaction of various sensorimotor sub-systems central to locomotor control. The goal of the present study was to develop new functional tests of locomotor control that could be used to test the efficacy of countermeasures. These tests were designed to simultaneously examine the function of multiple sensorimotor systems underlying the control of locomotion and be operationally relevant to the astronaut population. Traditionally, gaze stabilization has been studied almost exclusively in seated subjects performing target acquisition tasks requiring only the involvement of coordinated eye-head movements. However, activities like walking involve full-body movement and require coordination between lower limbs and the eye-head-trunk complex to achieve stabilized gaze during locomotion. Therefore the first goal of this study was to determine how the multiple, interdependent, full-body sensorimotor gaze stabilization subsystems are functionally coordinated during locomotion. In an earlier study we investigated how alteration in gaze tasking changes full-body locomotor control strategies. Subjects walked on a treadmill and either focused on a central point target or read numeral characters. We measured: temporal parameters of gait, full body sagittal plane segmental kinematics of the head, trunk, thigh, shank and foot, accelerations along the vertical axis at the head and the shank, and the vertical forces acting on the support surface. In comparison to the point target fixation condition, the results of the number reading task showed that compensatory head pitch movements increased, peak head acceleration was reduced and knee flexion at heel-strike was increased. In a more recent study we investigated the

  10. A computer vision based candidate for functional balance test.

    Science.gov (United States)

    Nalci, Alican; Khodamoradi, Alireza; Balkan, Ozgur; Nahab, Fatta; Garudadri, Harinath

    2015-08-01

    Balance in humans is a motor skill based on complex multimodal sensing, processing and control. Ability to maintain balance in activities of daily living (ADL) is compromised due to aging, diseases, injuries and environmental factors. Center for Disease Control and Prevention (CDC) estimate of the costs of falls among older adults was $34 billion in 2013 and is expected to reach $54.9 billion in 2020. In this paper, we present a brief review of balance impairments followed by subjective and objective tools currently used in clinical settings for human balance assessment. We propose a novel computer vision (CV) based approach as a candidate for functional balance test. The test will take less than a minute to administer and expected to be objective, repeatable and highly discriminative in quantifying ability to maintain posture and balance. We present an informal study with preliminary data from 10 healthy volunteers, and compare performance with a balance assessment system called BTrackS Balance Assessment Board. Our results show high degree of correlation with BTrackS. The proposed system promises to be a good candidate for objective functional balance tests and warrants further investigations to assess validity in clinical settings, including acute care, long term care and assisted living care facilities. Our long term goals include non-intrusive approaches to assess balance competence during ADL in independent living environments.

  11. The Reliability of a Functional Agility Test for Water Polo

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2014-07-01

    Full Text Available Few functional agility tests for water polo take into consideration its specific characteristics. The preliminary objective of this study was to evaluate the reliability of an agility test for water polo players. Fifteen players (16.3 ± 1.8 years old with a minimum of two years of competitive experience were evaluated. A Functional Test for Agility Performance (FTAP was designed to represent the context of this sport. Several trials were performed to familiarize the athlete with the movement. Two experienced coaches measured three repetitions of the FTAP. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. It was considered that certain criteria of reliability measures were met. There was no significant difference between the repetitions, which may be explained by an effect of the evaluator, the ability of the players or fatigue (p > 0.05. The ICC average from evaluators was high (0.88. The SEM varied between 0.13 s and 0.49 s. The CV average considering each individual was near 6-7%. These values depended on the condition of measurement. As the FTAP contains some characteristics that create a degree of unpredictability, the same athlete may reach different performance results, increasing variability. An adjustment in the sample, familiarization and careful selection of subjects help to improve this situation and enhance the reliability of the indicators.

  12. Hot functional test chemistry - long term experience

    International Nuclear Information System (INIS)

    Vonkova, K.; Kysela, J.; Marcinsky, M.; Martykan, M.

    2010-01-01

    Primary circuit materials undergo general corrosion in high temperature, deoxygenated, neutral or mildly alkaline solutions to form thin oxide films. These oxide layers (films) serve as protective film and mitigate the further corrosion of primary materials. Inner chromium-rich oxide layer has low cation diffusion coefficients and thus control iron and nickel transport from the metal surface to the outer layer and their dissolution into the coolant. Much less corrosion products are generated by the compact, integral and stable oxide (passivation) layer. For the latest Czech and Slovak stations commissioned (Temelin and Mochovce) a modified Hot Functional Test (HFT) chemistry was developed in the NRI Rez. Chromium rich surface layer formatted due to modified HTF chemistry ensures lower corrosion rates and radiation field formation and thus also mitigates crud formation during operation. This procedure was also designed to prepare the commissioned unit for the further proper water chemistry practise. Mochovce 1 (SK) was the first station commissioned using these recommendations in 1998. Mochovce 2 (1999) and Temelin 1 and 2 (CZ - 2000 and 2002) were subsequently commissioned using these guidelines too. The main principles of the controlled primary water chemistry applied during the hot functional tests are reviewed and importance of the water chemistry, technological and other relevant parameters is stressed regarding to the quality of the passive layer formed on the primary system surfaces. Samples from Mochovce indicated that duplex oxide layers up to 20 μm thick were produced, which were mainly magnetite substituted with nickel and chromium (e.g. 60-65% Fe, 18-28% Cr, 9-12% Ni, <1% Mn and 1-2% Si on a stainless steel primary circuit sample). Long term operation experience from both nuclear power plants are discussed in this paper. Radiation field, occupational radiation exposure and corrosion layers evolution during the first c. ten years of operation are

  13. Long-reach articulated robots for inspection and mini-invasive interventions in hazardous environments: Recent robotics research, qualification testing, and tool developments

    International Nuclear Information System (INIS)

    Perrot, Yann; Kammerer, Nolwenn; Measson, Yvan; Verney, Alexandre; Gargiulo, Laurent; Houry, Michael; Keller, Delphine; Piolain, Gerard

    2012-01-01

    The Interactive Robotics Laboratory of CEA LIST is in charge of the development of remote handling technologies to meet energy industry requirements. This paper reports the research and development activities in advanced robotics systems for inspection or light intervention in hazardous environments with limited access such as blind hot cells in the nuclear industry or the thermonuclear experimental Tokamak fusion reactor. A long-reach carrier robot called the articulated inspection arm (AIA) and diagnostics and tools for inspection or intervention are described. Finally experimental field tests are presented and actual challenges in modeling the robot's flexibilities are discussed. (authors)

  14. Functional testing of the ATLAS SCT barrels

    International Nuclear Information System (INIS)

    Phillips, Peter W.

    2007-01-01

    The ATLAS SCT (semiconductor tracker) comprises 2112 barrel modules mounted on four concentric barrels of length 1.6m and up to 1m diameter, and 1976 endcap modules supported by a series of nine wheels at each end of the barrel region, giving a total silicon area of 60m 2 . The assembly of modules onto each of the four barrel structures has recently been completed. In addition to functional tests made during the assembly process, each completed barrel was operated in its entirety. In the case of the largest barrel, with an active silicon area of approximately 10m 2 , this corresponds to more than one million instrumented channels. This paper documents the electrical performance of the four individual SCT barrels. An overview of the readout chain is also given

  15. Fort St. Vrain hot functional test results

    International Nuclear Information System (INIS)

    Phelps, R.D.

    1974-01-01

    A description is given of Fort St. Vrain hot functional tests performed to evaluate the initial nonnuclear performance of the primary coolant system and the associated effects on the various internal components of the reactor vessel and primary coolant system. The components included the twelve steam generator modules, the four helium circulators, the PCRV thermal barrier and liner coolant system, the helium purification system, and the primary and secondary closures at each of the PCRV penetrations. Additional objectives included analysis of the parallel operation of the four helium circulators and the performance of several circulator start/stop transients under various conditions of primary coolant temperature and pressure. Vibration and acoustical phenomena within the vessel were measured, recorded, and compared to theoretical analyses; a verification of reverse flow in the shutdown loop steam generator during one loop operation was performed; the PCRV was again observed for its structural response to internal pressure; and comparisons were made relative to data recorded during the initial pressure test completed in July 1971. (U.S.)

  16. The cost-effectiveness in the use of HIV counselling and testing-mobile outreaches in reaching men who have sex with men (MSM) in northern Nigeria.

    Science.gov (United States)

    Ifekandu, Chiedu; Suleiman, Aliyu; Aniekwe, Ogechukwu

    2014-01-01

    Men who have sex with men (MSM) are at increased risk of HIV and other STI infections in Nigeria. This is because MSM are afraid to seek medical help because the healthcare workers in various facilities are afraid of the consequences if they provide services for MSM citing the law as a reason not to intervene. MSM in northern states of Nigeria are facing double-jeopardy because the few international partners working in MSM in Nigeria are pulling out of these volatile areas because of the fear of attacks by the Boko Haram and the Nigerian law enforcement agencies. The intervention was conducted to promote affordable and sustainable HIV care and treatment for MSM in Nigeria. This intervention was conducted in the Boko Haram ravaged cities of Kano and Maiduguri (North-East Nigeria). Twenty MSM-key influencers from the two cities were identified and trained on HIV counselling and testing, caregivers, case managers and on initiation process for ARV treatment for new HIV+MSM as well as ethical considerations. The mean age of the key influencers was 24 years +/-SD. Each of the trained 20 key influencers reached 20 MSM-peer with condom promotion, HCT, referral to identified MSM-community health centers and follow-up/caregiving within the space of one month. The project was able to reach 400 MSM in the two cities. 89% of the peers consented to HCT. HIV prevalence among the participants was at 18%. The project recorded ARV-successful referral to healthcare facilities for the respondents that tested positive. The key influencers have been following up for ARV-adherence. Use of community members should be promoted for sustainability and ownership. It also helps in eradicating socio-cultural barrier to HIV intervention for MSM. Moreover, this proves to be one of the safest and affordable methods of reaching MSM in Nigeria in this ugly time of legalization of homophobia in the country's constitution.

  17. Gall bladder function test with Ceruletid

    International Nuclear Information System (INIS)

    Schindler, G.

    1981-01-01

    Compared with the stimulating food given orally in the gall bladder function test the administration of the decapeptide Ceruletid which is related with Cholecystokinin has the advantage of avoiding resorption disturbances in the upper gastrointestinal tract. To 100 patients with positive peroral cholecystography, Ceruletid was injected i.m. in a dose of 0.4 μg/kg body weight. The contrasting of the main bile duct was thus increased from 10% to 86%. The oral stimulating food brings an increase to appr. 20%. A special importance is assigned to the frequent diagnosis of adenomyomatoses which, with 6%, lies significantly above the 0.8% achieved by means of the oral stimulating food. More contractile segments of the gall bladder wall can cause pain symptoms which are typical for the biliary tract. Adenomyomatoses in the region of the infundibulum of the gall bladder cause colicky pains and are, as generally accepted, an absolute indication for a surgical intervention. The finding of small gall bladder conrements is often connected with a strong diminution of the gall bladder in order to prevent the small concrements from being overlapped by the non-contrasting bladder bile. Therefore, the application of Ceruletid should be considered also within the frame of the intravenous cholegraphy, thinking of the large number of normal gall bladder findings which were obtained with the oral stimulating food as the only diagnostical help. (orig./MG) [de

  18. Evaluation of reach and grasp robot-assisted therapy suggests similar functional recovery patterns on proximal and distal arm segments in sub-acute hemiplegia.

    Science.gov (United States)

    Loureiro, Rui C V; Harwin, William S; Lamperd, Robert; Collin, Christine

    2014-05-01

    This paper provides some additional evidence in support of the hypothesis that robot therapies are clinically beneficial in neurorehabilitation. Although only four subjects were included in the study, the design of the intervention and the measures were done so as to minimize bias. The results are presented as single case studies, and can only be interpreted as such due to the study size. The intensity of intervention was 16 h and the therapy philosophy (based on Carr and Shepherd) was that coordinated movements are preferable to joint based therapies, and that coordinating distal movements (in this case grasps) helps not only to recover function in these areas, but has greater value since the results are immediately transferable to daily skills such as reach and grasp movements.

  19. Significance tests for functional data with complex dependence structure

    KAUST Repository

    Staicu, Ana-Maria; Lahiri, Soumen N.; Carroll, Raymond J.

    2015-01-01

    We propose an L (2)-norm based global testing procedure for the null hypothesis that multiple group mean functions are equal, for functional data with complex dependence structure. Specifically, we consider the setting of functional data with a

  20. Quality of Liver and Kideny Function Test

    African Journals Online (AJOL)

    GB

    results for kidney functions and liver functions in. HIV diagnostic and monitoring laboratory are extremely important for decision making with patients under ART programs, and the consequences of erroneous results are huge (8, 9). 1University of Bahir Dar, Biological Inorganic Chemistry, P.O.Box-79, Bahir Dar, Ethiopia.

  1. From bottles to stream reaches and networks: Consequences of scale in how we interpret the function of freshwaters in the carbon cycle

    Science.gov (United States)

    Hotchkiss, E. R.

    2017-12-01

    Freshwater biological processes can alter the quantity and quality of organic carbon (OC) inputs from land before they are transported downstream, but the relative role of hydrologic transport and in-stream processing is still not well quantified at the scale of fluvial networks. Despite much research on the role of biology and hydrology in governing the form and fate of C in inland waters, conclusions about the function of freshwater ecosystems in modifying OC still largely depend on where we draw our ecosystem boundaries, i.e., the spatial scale of measurements used to assess OC transformations. Here I review freshwater OC uptake rates derived from bioassay incubations, synoptic modeling, reach-scale experiments, and ecosystem OC spiraling estimates. Median OC uptake velocities from standard bioassay incubations (0.02 m/d) and synoptic modeling (0.04 m/d) are 1-2 orders of magnitude lower than reach-scale experimental DOC additions and ecosystem OC spiraling estimates (2.2 and 0.27 m/d, respectively) in streams and rivers. Together, ecosystem metabolism and OC fluxes can be used to estimate the distance OC travels before being consumed and respired as CO2 through biological processes (i.e., OC spiraling), allowing for a more mechanistic understanding of the role of ecosystem processes and hydrologic fluxes in modifying downstream OC transport. Beyond the reach scale, data from stream network and stream-lake-river modeling simulations show how we may use linked sampling sites within networks to better understand the integrated sources and fate of OC in freshwaters. We currently underestimate the role of upstream processes in contributing to downstream fluxes: moving from single-ecosystem comparisons to linked-ecosystem simulations increases the contribution of in situ OC processing to CO2 emissions from 30% to >40%. Insights from literature reviews, ecosystem process measurements, and model simulations provide a framework for future considerations of integrated C

  2. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    Science.gov (United States)

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  3. THI: goal reached with a carbon beam, and some results of beam tests and theoretical studies related to longitudinal space charge effects

    International Nuclear Information System (INIS)

    Anon.

    1999-01-01

    During the first semester of this year, two tests were devoted to high intensity beams: 1) trying to reach the ultimate goal with a carbon beam and 2) going further into the study of perturbing phenomena. A 1.3 x 10 13 pps 13 C beam was successfully extracted from SSC2 and sustained for 13 hours with an excellent stability. Then, the current was increased to 2 x 10 13 pps with no major problem. Therefore, it is possible from now on to bombard the 2 kW target which is prepared for the production of helium isotopes and subsequent acceleration in the new cyclotron CIME. Both experimental and simulation studies were carried in parallel, in the frame of the last year expertise, in order to get a better knowledge and control of the effect of longitudinal space charge forces. It appears that these effects affect the beam width mostly in SSC2, while a discrepancy between computer simulations and measurements seems to show up concerning the effect of neighbouring bunches. (author)

  4. Reach Address Database (RAD)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Reach Address Database (RAD) stores the reach address of each Water Program feature that has been linked to the underlying surface water features (streams,...

  5. Platelet Function Tests: Preanalytical Variables, Clinical Utility, Advantages, and Disadvantages.

    Science.gov (United States)

    Hvas, Anne-Mette; Grove, Erik Lerkevang

    2017-01-01

    Platelet function tests are mainly used in the diagnostic work-up of platelet disorders. During the last decade, the additional use of platelet function tests to evaluate the effect of antiplatelet therapy has also emerged in an attempt to identify patients with an increased risk of arterial thrombosis. Furthermore, platelet function tests are increasingly used to measure residual effect of antiplatelet therapy prior to surgery with the aim of reducing the risk of bleeding. To a limited extend, platelet function tests are also used to evaluate hyperaggregability as a potential marker of a prothrombotic state outside the setting of antiplatelet therapy. This multifaceted use of platelet function tests and the development of simpler point-of-care tests with narrower application have increased the use of platelet function testing and also facilitated the use of platelet function tests outside the highly specialized laboratories. The present chapter describes the preanalytical variables, which should be taken into account when planning platelet function testing. Also, the most widely used platelet function tests are introduced, and their clinical utility and their relative advantages and disadvantages are discussed.

  6. Axial force measurement for esophageal function testing

    DEFF Research Database (Denmark)

    Gravesen, Flemming Holbæk; Funch-Jensen, Peter; Gregersen, Hans

    2009-01-01

    force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external...... force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been...... documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe...

  7. [Syncope: electrocardiogram and autonomic function tests].

    Science.gov (United States)

    Uribe, William; Baranchuk, Adrián; Botero, Federico

    2016-12-23

    Syncope represents one of the most frequent reasons for consultation in the emergency department. A proper identification will allow a precise etiologic approach and the optimization of delivery of health resources.
Once knowing the classification of syncope; it is the clinical interrogatory what enables to discriminate which of these patients present with a neurogenic mediated syncope or a cardiac mediated syncope. The use of diagnostic methods such as the tilt test, will clarify what type of neurally mediated syncope predominates in the patient.
The electrocardiogram is the cornerstone in the identification of those patients who had a true episode of self-limited or aborted sudden death as the first manifestation of their syncope, a fact which provides prognostic and therapeutic information that will impact the morbidity and mortality.

  8. Reaching the hard-to-reach.

    Science.gov (United States)

    Valdes, C

    1992-01-01

    Guatemala's family planning (FP) programs are innovative but contraceptive use is only 23%. Total fertility is 5.3 children/woman, and the 9.5 million population will double in 23 years. The problem is poverty and illiteracy among rural residents removed from health services. 80% live in poverty and 80% are illiterate. Government effort is devoted to combating diseases such as diarrhea so there are few funds for implementing a comprehensive population policy. There is support within the national government but FP lacks priority status. APROFAM's goals are to use innovative marketing methods to inform the rural population who lack access to and knowledge about FP. Service delivery is constrained by the difficulty in reaching remote areas where 4 out of 10 indigenous Guatemalans live. Infant mortality can reach as high as 200/1000 live births. Population growth has slowed, and APROFAM plans to reach 16,000 more in the future. Promotions are conducted in several languages and aired on radio, television, and in the print media. It has been found that market research is the most effective strategy in reaching indigenous families. APROFAM has also been effective in upgrading service facilities through training, client surveys, and setting improved clinic standards. Breastfeeding, training, and voluntary sterilization programs contribute to the primary care effort. The example is given of Paulina Lebron from a very poor area who has learned how to space her children and thus improve the standard of living for her family. Eventually, she convinced herself and her family that sterilization was necessary, and now the couple enjoy the bliss of newlyweds without fear of pregnancy.

  9. Executive Functioning Profiles and Test Anxiety in College Students

    Science.gov (United States)

    O'Donnell, Patrick S.

    2017-01-01

    The current study attempted to answer whether a specific executive functioning profile for individuals with test anxiety exists and whether deficits in working memory are associated with an earlier onset of test anxiety. Two hundred eighty-four undergraduate students completed a survey on test anxiety and self-report measures of test anxiety and…

  10. IMPORTANCE OF THYROID FUNCTION TEST IN DIABETES

    Directory of Open Access Journals (Sweden)

    Mohd.

    2015-05-01

    Full Text Available BACKGROUND : Thyroid disorder and Diabetes are both hormone and endocrine and problems. When thyroid disease occurs in someone with diabetes, it can make blood glucose control more difficult. The incidence and occurrence of thyroid diseases in general population is increasing more and more day by day . As the prevalence of diabetes and thyroid both is more in India, correlation of these two diseases was studied in this study. MATERIAL AND METHOD: this study was conducted on 105 diabetic (both type I and II patients attending Outpatient Department. Thyroid tests including TSH, and T4 were measured using enzyme immune assay. RESULTS: We have enrolled 105 patients which are Prediabetes, and Type 2 Diabetes Mellitus. Out of these 55 are male and 50 patients are females. 68 patients are on oral hypoglycemic drugs and 28 patients are on insulin with oral hypoglycemic agents, 09 patients were only on Diabetic D iet. We have observed that patient with diabetes predominantly females were having abnormal thyroid levels than compared to control group. Hypothyroidism was seen to be more common in females than in males in both the control and study group. Similarly hyp erthyroidism also seems to be common in females compared to males in both diabetic and non - diabetic groups (Perros P 1995. DISCUSSION: Abnormal thyroid hormone levels were observed more commonly in study group than in control group. Hypothyroidism was see n to be more common in females than in males in both the control and study group. Similarly hyperthyroidism also seems to be common in females compared to males in both diabetic and non - diabetic groups

  11. 15N liver function tests - concept, validity, clinical use

    International Nuclear Information System (INIS)

    Faust, H.; Jung, K.; Krumbiegel, P.; Hirschberg, K.; Reinhardt, R.; Junghans, P.

    1987-01-01

    Several liver function tests using the oral application of a nitrogen compound labelled with 15 N and the subsequent determination of 15 N in a certain fraction of urine by emission spectrometry are described. Because of the key position of the liver in the metabolism of nitrogen compounds the results of these tests allow conclusions concerning disturbances of special liver functions. Instructions for the clinical use of the '[ 15 N]Ammonium Test', '[ 15 N]Hippurate Test' the '[ 15 N]Methacetin Test', and the '[ 15 N]Glycine Test' are given. (author)

  12. Experimental fast reactor JOYO MK-III functional test. Primary auxiliary cooling system test

    International Nuclear Information System (INIS)

    Karube, Koji; Akagi, Shinji; Terano, Toshihiro; Onuki, Osamu; Ito, Hideaki; Aoki, Hiroshi; Odo, Toshihiro

    2004-03-01

    This paper describes the results of primary auxiliary cooling system, which were done as a part of JOYO MK-III function test. The aim of the tests was to confirm the operational performance of primary auxiliary EMP and the protection system including siphon breaker of primary auxiliary cooling system. The items of the tests were: (Test No.): (Test item). 1) SKS-117: EMP start up test. 2) SKS-118-1: EMP start up test when pony motor running. 3) SKS-121: Function test of siphon breaker. The results of the tests satisfied the required performance, and demonstrated successful operation of primary auxiliary cooling system. (author)

  13. 33 CFR 157.12f - Workshop functional test requirements.

    Science.gov (United States)

    2010-07-01

    ... CARRYING OIL IN BULK Design, Equipment, and Installation § 157.12f Workshop functional test requirements... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Workshop functional test requirements. 157.12f Section 157.12f Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND...

  14. Significance tests for functional data with complex dependence structure.

    Science.gov (United States)

    Staicu, Ana-Maria; Lahiri, Soumen N; Carroll, Raymond J

    2015-01-01

    We propose an L 2 -norm based global testing procedure for the null hypothesis that multiple group mean functions are equal, for functional data with complex dependence structure. Specifically, we consider the setting of functional data with a multilevel structure of the form groups-clusters or subjects-units, where the unit-level profiles are spatially correlated within the cluster, and the cluster-level data are independent. Orthogonal series expansions are used to approximate the group mean functions and the test statistic is estimated using the basis coefficients. The asymptotic null distribution of the test statistic is developed, under mild regularity conditions. To our knowledge this is the first work that studies hypothesis testing, when data have such complex multilevel functional and spatial structure. Two small-sample alternatives, including a novel block bootstrap for functional data, are proposed, and their performance is examined in simulation studies. The paper concludes with an illustration of a motivating experiment.

  15. Significance tests for functional data with complex dependence structure

    KAUST Repository

    Staicu, Ana-Maria

    2015-01-01

    We propose an L (2)-norm based global testing procedure for the null hypothesis that multiple group mean functions are equal, for functional data with complex dependence structure. Specifically, we consider the setting of functional data with a multilevel structure of the form groups-clusters or subjects-units, where the unit-level profiles are spatially correlated within the cluster, and the cluster-level data are independent. Orthogonal series expansions are used to approximate the group mean functions and the test statistic is estimated using the basis coefficients. The asymptotic null distribution of the test statistic is developed, under mild regularity conditions. To our knowledge this is the first work that studies hypothesis testing, when data have such complex multilevel functional and spatial structure. Two small-sample alternatives, including a novel block bootstrap for functional data, are proposed, and their performance is examined in simulation studies. The paper concludes with an illustration of a motivating experiment.

  16. A New Nonlinear Unit Root Test with Fourier Function

    OpenAIRE

    Güriş, Burak

    2017-01-01

    Traditional unit root tests display a tendency to be nonstationary in the case of structural breaks and nonlinearity. To eliminate this problem this paper proposes a new flexible Fourier form nonlinear unit root test. This test eliminates this problem to add structural breaks and nonlinearity together to the test procedure. In this test procedure, structural breaks are modeled by means of a Fourier function and nonlinear adjustment is modeled by means of an Exponential Smooth Threshold Autore...

  17. A test of conformal invariance: Correlation functions on a disk

    International Nuclear Information System (INIS)

    Badke, R.; Rittenberg, V.; Ruegg, H.

    1985-06-01

    Using conformal invariance one can derive the correlation functions of a disk from those in the half-plane. The correlation function in the half-plane is determined by the 'small' conformal invariance up to an unknown function of one variable. By measuring through the Monte Carlo method the correlation function for two different configurations, the unknown function can be eliminated and one obtains a test of conformal invariance. It is shown that the Ising and the three state Potts model pass the test for very small lattices. (orig.)

  18. Liver function tests using the stable istope 15N

    International Nuclear Information System (INIS)

    Faust, H.; Jung, K.; Hirschberg, K.; Krumbiegel, P.; Junghans, P.; Reinhardt, R.; Teichmann, B.

    1988-01-01

    Several liver function tests using oral application of a nitrogen compound labelled with 15 N and the subsequent determination of 15 N in a certain fraction of urine or in the total urine by emission spectrometry are described. Because of the key function of the liver in the metabolism of nitrogen compounds, the results of these tests allow conclusions concerning some disturbances of liver functions. (author)

  19. Liver function tests using the stable isotope /sup 15/N

    Energy Technology Data Exchange (ETDEWEB)

    Faust, H; Jung, K; Hirschberg, K; Krumbiegel, P; Junghans, P; Reinhardt, R; Matkowitz, R; Teichmann, B

    1988-01-01

    Several liver function tests using oral application of a nitrogen compound labelled with /sup 15/N and the subsequent determination of /sup 15/N in a certain fraction of urine or in the total urine by emission spectrometry are described. Because of the key function of the liver in the metabolism of nitrogen compounds, the results of these tests allow conclusions concerning some disturbances of liver functions.

  20. Functions and Design Scheme of Tibet High Altitude Test Base

    Institute of Scientific and Technical Information of China (English)

    Yu Yongqing; Guo Jian; Yin Yu; Mao Yan; Li Guangfan; Fan Jianbin; Lu Jiayu; Su Zhiyi; Li Peng; Li Qingfeng; Liao Weiming; Zhou Jun

    2010-01-01

    @@ The functional orientation of the Tibet High Altitude Test Base, subordinated to the State Grid Corporation of China (SGCC), is to serve power transmission projects in high altitude areas, especially to provide technical support for southwestern hydropower delivery projects by UHVDC transmission and Qinghai-Tibet grid interconnection project. This paper presents the matters concerned during siting and planning, functions,design scheme, the main performances and parameters of the test facilities, as well as the tests and research tasks already carried out.

  1. Bandwidth Analysis of Functional Interconnects Used as Test Access Mechanism

    NARCIS (Netherlands)

    Van den Berg, A.; Ren, P.; Marinissen, E.J.; Gaydadjiev, G.; Goossens, K.

    2010-01-01

    Test data travels through a System on Chip (SOC) from the chip pins to the Core-Under-Test (CUT) and vice versa via a Test Access Mechanism (TAM). Conventionally, a TAM is implemented using dedicated communication infrastructure. However, also existing functional interconnect, such as a bus or

  2. Bandwidth analysis of functional interconnects used as test access mechanism

    NARCIS (Netherlands)

    Berg, van den Ardy; Ren, P.; Marinissen, Erik Jan; Gaydadjiev, G.N.; Goossens, K.G.W.

    2010-01-01

    Test data travels through a System on Chip (SOC) from the chip pins to the Core-Under-Test (CUT) and vice versa via a Test Access Mechanism (TAM). Conventionally, a TAM is implemented using dedicated communication infrastructure. However, also existing functional interconnect, such as a bus or

  3. Detection of differential item functioning using Lagrange multiplier tests

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1998-01-01

    Abstract: In the present paper it is shown that differential item functioning can be evaluated using the Lagrange multiplier test or Rao’s efficient score test. The test is presented in the framework of a number of IRT models such as the Rasch model, the OPLM, the 2-parameter logistic model, the

  4. Detection of differential item functioning using Lagrange multiplier tests

    NARCIS (Netherlands)

    Glas, Cornelis A.W.

    1996-01-01

    In this paper it is shown that differential item functioning can be evaluated using the Lagrange multiplier test or C. R. Rao's efficient score test. The test is presented in the framework of a number of item response theory (IRT) models such as the Rasch model, the one-parameter logistic model, the

  5. Sensitivity and Specificity of Clinical and Laboratory Otolith Function Tests.

    Science.gov (United States)

    Kumar, Lokesh; Thakar, Alok; Thakur, Bhaskar; Sikka, Kapil

    2017-10-01

    To evaluate clinic based and laboratory tests of otolith function for their sensitivity and specificity in demarcating unilateral compensated complete vestibular deficit from normal. Prospective cross-sectional study. Tertiary care hospital vestibular physiology laboratory. Control group-30 healthy adults, 20-45 years age; Case group-15 subjects post vestibular shwannoma excision or post-labyrinthectomy with compensated unilateral complete audio-vestibular loss. Otolith function evaluation by precise clinical testing (head tilt test-HTT; subjective visual vertical-SVV) and laboratory testing (headroll-eye counterroll-HR-ECR; vesibular evoked myogenic potentials-cVEMP). Sensitivity and specificity of clinical and laboratory tests in differentiating case and control subjects. Measurable test results were universally obtained with clinical otolith tests (SVV; HTT) but not with laboratory tests. The HR-ECR test did not indicate any definitive wave forms in 10% controls and 26% cases. cVEMP responses were absent in 10% controls.HTT test with normative cutoff at 2 degrees deviations from vertical noted as 93.33% sensitive and 100% specific. SVV test with normative cutoff at 1.3 degrees noted as 100% sensitive and 100% specific. Laboratory tests demonstrated poorer specificities owing primarily to significant unresponsiveness in normal controls. Clinical otolith function tests, if conducted with precision, demonstrate greater ability than laboratory testing in discriminating normal controls from cases with unilateral complete compensated vestibular dysfunction.

  6. Power functional theory for the dynamic test particle limit

    International Nuclear Information System (INIS)

    Brader, Joseph M; Schmidt, Matthias

    2015-01-01

    For classical Brownian systems both in and out of equilibrium we extend the power functional formalism of Schmidt and Brader (2013 J. Chem. Phys. 138 214101) to mixtures of different types of particles. We apply the framework to develop an exact dynamical test particle theory for the self and distinct parts of the van Hove function, which characterize tagged and collective particle motion. The memory functions that induce non-Markovian dynamics are related to functional derivatives of the excess (over ideal) free power dissipation functional. The method offers an alternative to the recently found nonequilibrium Ornstein–Zernike relation for dynamic pair correlation functions. (paper)

  7. Adaptive mixed reality rehabilitation improves quality of reaching movements more than traditional reaching therapy following stroke.

    Science.gov (United States)

    Duff, Margaret; Chen, Yinpeng; Cheng, Long; Liu, Sheng-Min; Blake, Paul; Wolf, Steven L; Rikakis, Thanassis

    2013-05-01

    Adaptive mixed reality rehabilitation (AMRR) is a novel integration of motion capture technology and high-level media computing that provides precise kinematic measurements and engaging multimodal feedback for self-assessment during a therapeutic task. We describe the first proof-of-concept study to compare outcomes of AMRR and traditional upper-extremity physical therapy. Two groups of participants with chronic stroke received either a month of AMRR therapy (n = 11) or matched dosing of traditional repetitive task therapy (n = 10). Participants were right handed, between 35 and 85 years old, and could independently reach to and at least partially grasp an object in front of them. Upper-extremity clinical scale scores and kinematic performances were measured before and after treatment. Both groups showed increased function after therapy, demonstrated by statistically significant improvements in Wolf Motor Function Test and upper-extremity Fugl-Meyer Assessment (FMA) scores, with the traditional therapy group improving significantly more on the FMA. However, only participants who received AMRR therapy showed a consistent improvement in kinematic measurements, both for the trained task of reaching to grasp a cone and the untrained task of reaching to push a lighted button. AMRR may be useful in improving both functionality and the kinematics of reaching. Further study is needed to determine if AMRR therapy induces long-term changes in movement quality that foster better functional recovery.

  8. Usng subjective percentiles and test data for estimating fragility functions

    International Nuclear Information System (INIS)

    George, L.L.; Mensing, R.W.

    1981-01-01

    Fragility functions are cumulative distribution functions (cdfs) of strengths at failure. They are needed for reliability analyses of systems such as power generation and transmission systems. Subjective opinions supplement sparse test data for estimating fragility functions. Often the opinions are opinions on the percentiles of the fragility function. Subjective percentiles are likely to be less biased than opinions on parameters of cdfs. Solutions to several problems in the estimation of fragility functions are found for subjective percentiles and test data. How subjective percentiles should be used to estimate subjective fragility functions, how subjective percentiles should be combined with test data, how fragility functions for several failure modes should be combined into a composite fragility function, and how inherent randomness and uncertainty due to lack of knowledge should be represented are considered. Subjective percentiles are treated as independent estimates of percentiles. The following are derived: least-squares parameter estimators for normal and lognormal cdfs, based on subjective percentiles (the method is applicable to any invertible cdf); a composite fragility function for combining several failure modes; estimators of variation within and between groups of experts for nonidentically distributed subjective percentiles; weighted least-squares estimators when subjective percentiles have higher variation at higher percents; and weighted least-squares and Bayes parameter estimators based on combining subjective percentiles and test data. 4 figures, 2 tables

  9. Global reach and engagement

    Science.gov (United States)

    2016-09-01

    Popular culture reflects both the interests of and the issues affecting the general public. As concerns regarding climate change and its impacts grow, is it permeating into popular culture and reaching that global audience?

  10. Pulmonary function tests in patients with Parkinson's disease: A ...

    African Journals Online (AJOL)

    Methods: Pulmonary function test (PFT) was conducted using the Spirolab Spirometry kit, and results of forced vital capacity ... [3] Though the effects of PD on respiration are still a .... patient becomes sedentary, and exercise training as a part.

  11. Platelet function testing: methods of assessment and clinical utility.

    LENUS (Irish Health Repository)

    Mylotte, Darren

    2012-02-01

    Platelets play a central role in the regulation of both thrombosis and haemostasis yet tests of platelet function have, until recently, been exclusively used in the diagnosis and management of bleeding disorders. Recent advances have demonstrated the clinical utility of platelet function testing in patients with cardiovascular disease. The ex vivo measurement of response to antiplatelet therapies (aspirin and clopidogrel), by an ever-increasing array of platelet function tests, is with some assays, predictive of adverse clinical events and thus, represents an emerging area of interest for both the clinician and basic scientist. This review article will describe the advantages and disadvantages of the currently available methods of measuring platelet function and discuss both the limitations and emerging data supporting the role of platelet function studies in clinical practice.

  12. Platelet function testing: methods of assessment and clinical utility.

    LENUS (Irish Health Repository)

    Mylotte, Darren

    2011-01-01

    Platelets play a central role in the regulation of both thrombosis and haemostasis yet tests of platelet function have, until recently, been exclusively used in the diagnosis and management of bleeding disorders. Recent advances have demonstrated the clinical utility of platelet function testing in patients with cardiovascular disease. The ex vivo measurement of response to antiplatelet therapies (aspirin and clopidogrel), by an ever-increasing array of platelet function tests, is with some assays, predictive of adverse clinical events and thus, represents an emerging area of interest for both the clinician and basic scientist. This review article will describe the advantages and disadvantages of the currently available methods of measuring platelet function and discuss both the limitations and emerging data supporting the role of platelet function studies in clinical practice.

  13. Evaluation of snubber functional test methods: Tier 1

    International Nuclear Information System (INIS)

    Brown, D.P.

    1993-07-01

    The objective of the research is to establish technical bases in support of efforts on the part of the Snubber Utility Group (SNUG) and the Subsection ISTD Working Group of the ASME O ampersand M Code in developing guidelines and methodologies for snubber functional testing to ensure that snubbers are tested in a manner that ensures reliable and meaningful test results. The methodology used in this research includes both a review of available industry information as well as the testing of different snubber models using various test machines. Information is provided pertaining to current industry practices in regard to snubber testing including recommended test procedures, technical description of various test machines, and the number and types of snubbers used in the nuclear power industry. A review of previous test methodology research conducted by the Snubber Utility Group is also included. The effects of variations in controllable test parameters on snubber test results are discussed. Also included are the results of confirmatory tests in which various snubber models were tested using various test machines. Recommendations are provided for standard test methods to be included in Subsection ISTD of the ASME O ampersand M Code [4]. General information and recommendations are provided that may be used by utility personnel in specifying snubber test equipment that is most suited for plant-specific needs as well as information that may be effectively used in the review and interpretation of test results

  14. MAVL wastes containers functional demonstration and associated tests program

    International Nuclear Information System (INIS)

    Templier, J.C.

    2002-01-01

    In the framework of studies on the MAVL wastes, the CEA develops containers for middle time wastes storage. This program aims to realize a ''B wastes containers'' demonstrator. A demonstrator is a container, parts of a container or samples which must validate the tests. This document presents the state of the study in the following three chapters: functions description, base data and design choices; presentation of the functional demonstrators; demonstration tests description. (A.L.B.)

  15. Formal Functional Test Designs: Bridging the Gap Between Test Requirements and Test Specifications

    Science.gov (United States)

    Hops, Jonathan

    1993-01-01

    This presentation describes the testing life cycle, the purpose of the test design phase, and test design methods and gives an example application. Also included is a description of Test Representation Language (TRL), a summary of the language, and an example of an application of TRL. A sample test requirement and sample test design are included.

  16. Safety and Function Test Report for the SWIFT Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, I.; Hur, J.

    2013-01-01

    This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. Three turbines where selected for testing at the National Wind Technology Center (NWTC) as a part of round two of the Small Wind Turbine Independent Testing project. Safety and Function testing is one of up to 5 tests that may be performed on the turbines. Other tests include power performance, duration, noise, and power quality. The results of the testing will provide the manufacturers with reports that may be used for small wind turbine certification.

  17. Thyroid function testing in women who had a stillbirth

    NARCIS (Netherlands)

    Nijkamp, Janna W.; Korteweg, Fleurisca J.; Groen, Henk; Timmer, Albertus; Van den Berg, Gerrit; Bossuyt, Patrick M.; Mol, Ben Willem J.; Erwich, Jan Jaap H. M.

    ContextThyroid dysfunction is thought to be associated with stillbirth. Therefore, thyroid function is often recommended in the diagnostic investigations for stillbirth. ObjectiveWe aimed to evaluate the added value of thyroid function testing in the diagnostic investigations for stillbirth. Design

  18. Polynomial regression analysis and significance test of the regression function

    International Nuclear Information System (INIS)

    Gao Zhengming; Zhao Juan; He Shengping

    2012-01-01

    In order to analyze the decay heating power of a certain radioactive isotope per kilogram with polynomial regression method, the paper firstly demonstrated the broad usage of polynomial function and deduced its parameters with ordinary least squares estimate. Then significance test method of polynomial regression function is derived considering the similarity between the polynomial regression model and the multivariable linear regression model. Finally, polynomial regression analysis and significance test of the polynomial function are done to the decay heating power of the iso tope per kilogram in accord with the authors' real work. (authors)

  19. Correlation with liver scintigram, reticuloendothelial function test, plasma endotoxin level and liver function tests in chronic liver diseases. Multivariate analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ohmoto, Kenji; Yamamoto, Shinichi; Ideguchi, Seiji and others

    1989-02-01

    Liver scintigrams with Tc-99m phytate were reviewed in a total of 64 consecutive patients, comprising 28 with chronic hepatitis and 36 with liver cirrhosis. Reticuloendothelial (RES) function, plasma endotoxin (Et) levels and findings of general liver function tests were used as reference parameters to determine the diagnostic ability of liver scintigraphy. Multivariate analyses revealed that liver scintigrams had a strong correlation with RES function and Et levels in terms of morphology of the liver and hepatic and bone marrow Tc-99m uptake. General liver function tests revealed gamma globulin to be correlated with hepatic uptake and the degree of splenogemaly on liver scintigrams; and ICG levels at 15 min to be correlated with bone marrow and splenic uptake. Accuracy of liver scintigraphy was 73% for chronic hepatitis, which was inferior to general liver function tests (83%). When both modalities were combined, diangostic accuracy increased to 95%. Liver scintigraphy seems to be useful as a complementary approach. (Namekawa, K).

  20. Testing REACH draft technical guidance notes for conducting chemical safety assessments-the experience of a downstream user of a preparation.

    Science.gov (United States)

    Gade, Anne Lill; Ovrebø, Steinar; Hylland, Ketil

    2008-07-01

    The goal of REACH is the safe use of chemicals. This study examines the efficiency and usefulness of two draft technical guidance notes in the REACH Interim Project 3.2-2 for the development of the chemical safety report and exposure scenarios. A case study was carried out for a paint system for protection of structural steel. The focuses of the study were risk assessment of preparations based on Derived No Effect Level (DNEL) and Predicted No Effect Concentrations (PNEC) and on effective and accurate communication in the supply chain. Exposure scenarios and generic descriptions of uses, risk management measures, and exposure determinants were developed. The study showed that communication formats, software tools, and guidelines for chemical risk assessment need further adjustment to preparations and real-life situations. Web platforms may simplify such communication. The downstream formulator needs basic substance data from the substance manufacturer during the pre-registration phase to develop exposure scenarios for preparations. Default values need to be communicated in the supply chain because these were critical for the derivation of applicable risk management demands. The current guidelines which rely on the available toxicological knowledge are insufficient to advise downstream users on how to develop exposure scenarios for preparations.

  1. Correlation between HRCT and pulmonary functional tests in cystic fibrosis

    International Nuclear Information System (INIS)

    Mastellari, Paola; Biggi, Simona; Lombardi, Alfonsa; Zompatori, Maurizio; Grzincich, Gianluigi; Pisi, Giovanna; Spaggiari, Cinzia

    2005-01-01

    Purpose. To compare the HRCT score by Oikonottlou and air trapping in expiratory scans with pulmonary functional tests and evaluate which radiological criteria are more useful to predict clinical impairment. Materials and methods. From January to September 2003, pulmonary HRCT study was performed in 37 patients (23 males), aged between 7 and 41 years, with cystic fibrosis. In the same day of CT examination they also received a complete functional evaluation. HRCT studies were evaluated by three radiologists blinded to the clinical data and were correlated with the lung function tests. Results. We obtained a high correlation (p=0.01) for two of the HRCT signs: extent of mucus plugging and mosaic perfusion pattern and all function tests. Discussion. Previous studies have demonstrated good correlation between lung function tests, in particular with FEV1 and HRCT signs. Our study differed from previous ones in that we analysed the correlation between lung function tests and with both single and combined CT criteria. Conclusion. Our results suggest that a simplified HRCT store could be useful to evaluate patients with cystic fibrosis [it

  2. Dynamic behavior and functional integrity tests on RC shear walls

    International Nuclear Information System (INIS)

    Akino, Kinji; Nasuda, Toshiaki; Shibata, Akenori.

    1991-01-01

    A project consisting of seven subprojects has been conducted to study the dynamic behavior and functional integrity of reinforced concrete (RC) shear walls in reactor buildings. The objective of this project is to obtain the data to improve and prepare the seismic analysis code regarding the nonlinear structural behavior and integrity of reactor buildings during and after earthquakes. The project started in April, 1986, and will end in March, 1994. Seven subprojects are strain rate test, damping characteristic test, ultimate state response test and the verification test for the test of restoring force characteristics regarding dynamic restoring force characteristics and damping performance; the restoring force characteristic test on the shear walls with openings; and pull-out strength test and the test on air leakage through concrete cracks regarding the functional integrity. The objectives of respective subprojects, the test models and the interim results are reported. Three subprojects have been completed by March, 1990. The results of these projects will be used for the overall evaluation. The strain rate test showed that the ultimate strength of shear walls increased with strain rate. A formula for estimating air flow through the cracks in walls was given by the leakage test. (K.I.)

  3. Development of a battery of functional tests for low vision.

    Science.gov (United States)

    Dougherty, Bradley E; Martin, Scott R; Kelly, Corey B; Jones, Lisa A; Raasch, Thomas W; Bullimore, Mark A

    2009-08-01

    We describe the development and evaluation of a battery of tests of functional visual performance of everyday tasks intended to be suitable for assessment of low vision patients. The functional test battery comprises-Reading rate: reading aloud 20 unrelated words for each of four print sizes (8, 4, 2, & 1 M); Telephone book: finding a name and reading the telephone number; Medicine bottle label: reading the name and dosing; Utility bill: reading the due date and amount due; Cooking instructions: reading cooking time on a food package; Coin sorting: making a specified amount from coins placed on a table; Playing card recognition: identifying denomination and suit; and Face recognition: identifying expressions of printed, life-size faces at 1 and 3 m. All tests were timed except face and playing card recognition. Fourteen normally sighted and 24 low vision subjects were assessed with the functional test battery. Visual acuity, contrast sensitivity, and quality of life (National Eye Institute Visual Function Questionnaire 25 [NEI-VFQ 25]) were measured and the functional tests repeated. Subsequently, 23 low vision patients participated in a pilot randomized clinical trial with half receiving low vision rehabilitation and half a delayed intervention. The functional tests were administered at enrollment and 3 months later. Normally sighted subjects could perform all tasks but the proportion of trials performed correctly by the low vision subjects ranged from 35% for face recognition at 3 m, to 95% for the playing card identification. On average, low vision subjects performed three times slower than the normally sighted subjects. Timed tasks with a visual search component showed poorer repeatability. In the pilot clinical trial, low vision rehabilitation produced the greatest improvement for the medicine bottle and cooking instruction tasks. Performance of patients on these functional tests has been assessed. Some appear responsive to low vision rehabilitation.

  4. Reference Values of Pulmonary Function Tests for Canadian Caucasians

    Directory of Open Access Journals (Sweden)

    Carlos Gutierrez

    2004-01-01

    Full Text Available A multicentre, cross-sectional study was carried out in six centres across Canada to establish a national standard for pulmonary function tests using healthy, lifetime nonsmokers, with each centre aiming to test 10 men and 10 women from each decade from 20 to 80 years of age. Data from each centre were used to derive prediction equations for each centre, and pooled data from all centres (total: 327 women and 300 men were used to derive Canadian predicted equations. The predictive models were compared with three widely used published models for selected tests. It was found that, in general, the equations modelled for each centre could be replaced by the models obtained when pooling all data (Canadian model. Comparisons with the published references showed good agreement and similar slopes for most tests. The results suggest that pulmonary function test results obtained from different centres in Canada were comparable and that standards currently used remain valid for Canadian Caucasians.

  5. Automated Functional Testing based on the Navigation of Web Applications

    Directory of Open Access Journals (Sweden)

    Boni García

    2011-08-01

    Full Text Available Web applications are becoming more and more complex. Testing such applications is an intricate hard and time-consuming activity. Therefore, testing is often poorly performed or skipped by practitioners. Test automation can help to avoid this situation. Hence, this paper presents a novel approach to perform automated software testing for web applications based on its navigation. On the one hand, web navigation is the process of traversing a web application using a browser. On the other hand, functional requirements are actions that an application must do. Therefore, the evaluation of the correct navigation of web applications results in the assessment of the specified functional requirements. The proposed method to perform the automation is done in four levels: test case generation, test data derivation, test case execution, and test case reporting. This method is driven by three kinds of inputs: i UML models; ii Selenium scripts; iii XML files. We have implemented our approach in an open-source testing framework named Automatic Testing Platform. The validation of this work has been carried out by means of a case study, in which the target is a real invoice management system developed using a model-driven approach.

  6. Computer Forensic Function Testing: Media Preparation, Write Protection And Verification

    Directory of Open Access Journals (Sweden)

    Yinghua (David Guo

    2010-06-01

    Full Text Available Normal 0 false false false EN-US JA AR-SA The growth in the computer forensic field has created a demand for new software (or increased functionality to existing software and a means to verify that this software is truly forensic i.e. capable of meeting the requirements of the trier of fact. In this work, we review our previous work---a function oriented testing framework for validation and verification of computer forensic tools. This framework consists of three parts: function mapping, requirements specification and reference set development. Through function mapping, we give a scientific and systemical description of the fundamentals of computer forensic discipline, i.e. what functions are needed in the computer forensic investigation process. We focus this paper on the functions of media preparation, write protection and verification. Specifically, we complete the function mapping of these functions and specify their requirements. Based on this work, future work can be conducted to develop corresponding reference sets to test any tools that possess these functions.

  7. Evaluation of thyroid function tests in non-thyroidal illness

    International Nuclear Information System (INIS)

    Schutte, D.P.

    1988-01-01

    Normal thyroid physiology and pathophysiology with reference to non-thyroidal illness (NTI) is reviewed including specific disease states and drugs and their effect on thyroid function tests. The diagnostic utility of two new highly sensitive thyrotrophin (TSH) assays as screening tests for thyroid dysfunction are evaluated and compared with conventional thyroid function assays. A group of 40 patients with NTI was studied. This group was compared to a group of normal controls and a group of thyrotoxic patients. Conventional thyroid function tests yielded many values outside the reference range in the NTI group. The general pattern that emerged was decreased total triiodothyronine levels in 70% of NTI patients, normal to low thyroxine values, increased mean free thyroxine values (dialysis), low mean values for the free thyroxine index and varying results for newer commercial assays for free thyroxine according to methodology. The TSH response to intravenous thyroliberin (TRH) was found to be blunted compared to controls. Basal TSH levels were measured with two ultasensitive TSH assays. The immunoradiometric assays yielded fewer values outside the reference range in the NTI group than conventional thyroid function tests. This assay yielded undetectable basal TSH levels in all thyrotoxic patients and could reliably separate thyrotoxic patients from the NTI group. Basal TSH levels with ultrasensitive TSH assays correlated well with the TSH response to TRH (TSH) and could obviate the need for TRH tests. Ultrasensitive TSH assays are promising first line screening tests in NTI. 120 refs., 13 figs., 7 tabs

  8. SP-100 nuclear assembly test: Test assembly functional requirements and system arrangement

    International Nuclear Information System (INIS)

    Fallas, T.T.; Gluck, R.; Motwani, K.; Clay, H.; O'Neill, G.

    1991-01-01

    This paper describes the functional requirements and the system that will be tested to validate the reactor, flight shield, and flight controller of the SP-100 Generic Flight System (GFS). The Nuclear Assembly Test (NAT) consists of the test article (SP-100 reactor with control devices and the flight shield) and its supporting systems. The NAT test assembly is being designed by GE. Westinghouse Hanford Company (WHC) is designing the test cell and vacuum vessel system that will contain the NAT test assembly (Renkey et al. 1989). Preliminary design reviews have been completed and the final design is under way

  9. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    Science.gov (United States)

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  10. Outcomes of anatomical versus functional testing for coronary artery disease.

    Science.gov (United States)

    Douglas, Pamela S; Hoffmann, Udo; Patel, Manesh R; Mark, Daniel B; Al-Khalidi, Hussein R; Cavanaugh, Brendan; Cole, Jason; Dolor, Rowena J; Fordyce, Christopher B; Huang, Megan; Khan, Muhammad Akram; Kosinski, Andrzej S; Krucoff, Mitchell W; Malhotra, Vinay; Picard, Michael H; Udelson, James E; Velazquez, Eric J; Yow, Eric; Cooper, Lawton S; Lee, Kerry L

    2015-04-02

    Many patients have symptoms suggestive of coronary artery disease (CAD) and are often evaluated with the use of diagnostic testing, although there are limited data from randomized trials to guide care. We randomly assigned 10,003 symptomatic patients to a strategy of initial anatomical testing with the use of coronary computed tomographic angiography (CTA) or to functional testing (exercise electrocardiography, nuclear stress testing, or stress echocardiography). The composite primary end point was death, myocardial infarction, hospitalization for unstable angina, or major procedural complication. Secondary end points included invasive cardiac catheterization that did not show obstructive CAD and radiation exposure. The mean age of the patients was 60.8±8.3 years, 52.7% were women, and 87.7% had chest pain or dyspnea on exertion. The mean pretest likelihood of obstructive CAD was 53.3±21.4%. Over a median follow-up period of 25 months, a primary end-point event occurred in 164 of 4996 patients in the CTA group (3.3%) and in 151 of 5007 (3.0%) in the functional-testing group (adjusted hazard ratio, 1.04; 95% confidence interval, 0.83 to 1.29; P=0.75). CTA was associated with fewer catheterizations showing no obstructive CAD than was functional testing (3.4% vs. 4.3%, P=0.02), although more patients in the CTA group underwent catheterization within 90 days after randomization (12.2% vs. 8.1%). The median cumulative radiation exposure per patient was lower in the CTA group than in the functional-testing group (10.0 mSv vs. 11.3 mSv), but 32.6% of the patients in the functional-testing group had no exposure, so the overall exposure was higher in the CTA group (mean, 12.0 mSv vs. 10.1 mSv; P<0.001). In symptomatic patients with suspected CAD who required noninvasive testing, a strategy of initial CTA, as compared with functional testing, did not improve clinical outcomes over a median follow-up of 2 years. (Funded by the National Heart, Lung, and Blood Institute

  11. Pathophysiology of recent advances in current thyroid function testing

    International Nuclear Information System (INIS)

    Hesch, R.D.

    1977-01-01

    In the first chapter I have discussed thyroid function and thyroid status which is determined by thyroid gland function in secreting T4 and peripheral biotransformation of T4. The accuracy of a current in-vitro diagnostic strategy allows high reliability in clinical routine. More recent test procedures for iodothyronines and immunological phenomena need further evaluation. In another chapter the biotransformation of T4 to bioactive and regulatory iodothyronines with respect to possible clinical implications is discussed. Finally, the role of TBG for interpration of T4 and T3 concentrations is determined and more attention directed to its functional heterogeneity. (orig.) [de

  12. Applicability of the fish embryo acute toxicity (FET) test (OECD 236) in the regulatory context of Registration, Evaluation, Authorisation, and Restriction of Chemicals (REACH).

    NARCIS (Netherlands)

    Sobanska, Marta; Scholz, Stefan; Nyman, Anna-Maija; Cesnaitis, Romanas; Gutierrez Alonso, Simon; Klüver, Nils; Kühne, Ralph; Tyle, Henrik; de Knecht, Joop; Dang, Zhichao; Lundbergh, Ivar; Carlon, Claudio; De Coen, Wim

    In 2013 the Organisation for Economic Co-operation and Development (OECD) test guideline (236) for fish embryo acute toxicity (FET) was adopted. It determines the acute toxicity of chemicals to embryonic fish. Previous studies show a good correlation of FET with the standard acute fish toxicity

  13. The added value of chlamydia screening between 2008-2010 in reaching young people in addition to chlamydia testing in regular care; an observational study

    NARCIS (Netherlands)

    van Liere, Geneviève; Dukers-Muijrers, Nicole; van Bergen, Jan; Götz, Hannelore M.; Stals, Frans; Hoebe, Christian

    2014-01-01

    Background: Internet-based Chlamydia Screening Implementation (chlamydia screening programme) was introduced in the Netherlands in 2008-2010 to detect and treat asymptomatic infections and to limit ongoing transmission through annual testing and treatment of Chlamydia trachomatis in young people

  14. Semipalatinsk nuclear test site: History of building and function

    International Nuclear Information System (INIS)

    Sergazina, G.M.; Balmukhanov, S.B.

    1999-01-01

    A vast materials on history of Semipalatinsk nuclear test site creation and it building and function are presented. Authors with big reliability report one page of Kazakhstan's history. In steppe on naked place thousands of soldiers and officers, construct and military specialists have built the nuclear site on which during 40 years were conducting nuclear tests . Prolonged chronic radiation on population living near by site results to tragedy which is confessed by General Assembly of United Nations. In the book aspects of test site conversion and rehabilitation of injured population are considered. The book consists of introduction, three chapters and conclusion. The book is intended to wide circle of readers. (author)

  15. The Functional Task Test (FTT): An Interdisciplinary Testing Protocol to Investigate the Factors Underlying Changes in Astronaut Functional Performance

    Science.gov (United States)

    Bloomberg, J. J.; Lawrence, E. L.; Arzeno, N. M.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts. S. H.; hide

    2011-01-01

    Exposure to space flight causes adaptations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. To achieve this goal we developed an interdisciplinary testing protocol (Functional Task Test, FTT) that evaluates both astronaut functional performance and related physiological changes. Functional tests include ladder climbing, hatch opening, jump down, manual manipulation of objects and tool use, seat egress and obstacle avoidance, recovery from a fall and object translation tasks. Physiological measures include assessments of postural and gait control, dynamic visual acuity, fine motor control, plasma volume, orthostatic intolerance, upper- and lower-body muscle strength, power, endurance, control, and neuromuscular drive. Crewmembers perform this integrated test protocol before and after short (Shuttle) and long-duration (ISS) space flight. Data are collected on two sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Preliminary results from both Shuttle and ISS crewmembers indicate decrement in performance of the functional tasks after both short and long-duration space flight. On-going data collection continues to improve the statistical power required to map changes in functional task performance to alterations in physiological systems. The information obtained from this study will be used to design and implement countermeasures that specifically target the physiological systems most responsible for the altered functional performance associated with space flight.

  16. [Eosin Y-water test for sperm function examination].

    Science.gov (United States)

    Zha, Shu-wei; Lü, Nian-qing; Xu, Hao-qin

    2015-06-01

    Based on the principles of the in vitro staining technique, hypotonic swelling test, and water test, the Eosin Y-water test method was developed to simultaneously detect the integrity of the sperm head and tail and sperm membrane structure and function. As a widely used method in clinical laboratories in China, the Eosin Y-water test is methodologically characterized by three advantages. Firstly, both the sperm head and tail can be detected at the same time, which allows easy and comprehensive assessment of membrane damage in different parts of sperm. Secondly, distilled water is used instead of the usual formula solution to simplify and standardize the test by eliminating any potential effects on the water molecules through the sperm membrane due to different osmotic pressure or different sugar proportions and electrolyte solutions. Thirdly, the test takes less time and thus can be repeated before and after treatment. This article focuses on the fundamental principles and modification of the Eosin Y-water test and its application in sperm function examination and routine semen analysis for male infertility, assessment of the quality of sperm retrieved by testicular fine needle aspiration, semen cryopreservation program development, and evaluation of sperm membrane integrity after microwave radiation.

  17. Use of functional tests in radioimmune diagnosis of endocrine diseases

    International Nuclear Information System (INIS)

    Slavnov, V.N.

    1988-01-01

    Radioimmunoassay for determining corticotropin (ACTH), somatotropin (STH), prolactin (LTH) and thyrotropin (TTH) concentration in blood for endocrine disease diagnosis are described. Reactions of earlier mentioned functional tests to specific stimulators and inhibitors for differential diagnosis of such diseases as Icenko-Cushing one, pituitary body and hypothalamus diseases, galactorrhea and amenorrhea syndrome are considered. The diagnosis reliability is underlined

  18. Obtaining reliable Likelihood Ratio tests from simulated likelihood functions

    DEFF Research Database (Denmark)

    Andersen, Laura Mørch

    It is standard practice by researchers and the default option in many statistical programs to base test statistics for mixed models on simulations using asymmetric draws (e.g. Halton draws). This paper shows that when the estimated likelihood functions depend on standard deviations of mixed param...

  19. Numerical distribution functions of fractional unit root and cointegration tests

    DEFF Research Database (Denmark)

    MacKinnon, James G.; Nielsen, Morten Ørregaard

    We calculate numerically the asymptotic distribution functions of likelihood ratio tests for fractional unit roots and cointegration rank. Because these distributions depend on a real-valued parameter, b, which must be estimated, simple tabulation is not feasible. Partly due to the presence...

  20. 20 CFR 718.103 - Pulmonary function tests.

    Science.gov (United States)

    2010-04-01

    ... of the forced expiratory volume in one second (FEV1) and the forced vital capacity (FVC). The report... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Pulmonary function tests. 718.103 Section 718... DEATH DUE TO PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.103 Pulmonary...

  1. Effect of Differential Item Functioning on Test Equating

    Science.gov (United States)

    Kabasakal, Kübra Atalay; Kelecioglu, Hülya

    2015-01-01

    This study examines the effect of differential item functioning (DIF) items on test equating through multilevel item response models (MIRMs) and traditional IRMs. The performances of three different equating models were investigated under 24 different simulation conditions, and the variables whose effects were examined included sample size, test…

  2. Prevalence of abnormal liver function tests in rheumatoid arthritis ...

    African Journals Online (AJOL)

    Objective: To determine the prevalence of Abnormal Liver Function Tests (LFTs) in patients with rheumatoid arthritis at the rheumatology out-patient clinic, Kenyatta National Hospital (KNH). Design: Cross-sectional descriptive study. Setting: Rheumatology out-patient clinic at KNH. Participants: One hundred and seven RA ...

  3. Quality of Liver and Kidney Function Tests among Public Medical ...

    African Journals Online (AJOL)

    The aim of this study is to assess the accuracy and precision of clinical chemistry laboratories in western region of Amhara national regional state of Ethiopia in testing liver and kidney functions. Methods: Eight laboratories in hospitals and a Regional Health Research Laboratory Center participated in this study from ...

  4. Effect of drugs on the thyroid function tests

    International Nuclear Information System (INIS)

    Cardoso, G.P.; Faria, A.C.S. de; Carvalho, M.C. de; Guimaraes, M.M.; Cordeiro, J.G.H.; Santa Casa do Rio de Janeiro

    1984-01-01

    The effects of drugs in the results of thyroid function tests, which could lead to misinterpretation of the real clinical state of the patients, are reviewed. The aspects of the metabolism of the thyreoidean hormones which could be related to these alterations are presented. (Author) [pt

  5. Lung Function Test in Asthmatics Patients in UBTH: Medical ...

    African Journals Online (AJOL)

    2004-06-30

    This report describes the result of a study on lung function tests on 75 asthmatics seen within a 6-month period (January 1 to June 30, 2004) at the University of Benin Teaching Hospital (UBTH), Benin City, Nigeria. There was a preponderance of females (60%) to males (40%); The result also showed that a large proportion ...

  6. Making sense of thyroid function tests | Gezawa | Nigerian Journal of ...

    African Journals Online (AJOL)

    Background: Thyroid disorders are second only to diabetes mellitus among endocrine problems encountered in practice. Many patients with thyroid disorders tend to present with nonspecific symptoms to clinicians in different specialties, who are often quick to request for a thyroid function test. Although interpretation of the ...

  7. Functional Literacy Tests: A Case of Anticipatory Validity?

    Science.gov (United States)

    Anderson, Lorin W.; Anderson, Jo Craig

    1981-01-01

    Development of the mathematics functional literacy test (MFLT) is described, issues of predictive and content validity are discussed, and implications for educational policy are presented. Ten basic skill areas identified by the National Council of Supervisors of Mathematics were used as the basis for the development of the MFLT. (RL)

  8. The emerging role of transport systems in liver function tests

    NARCIS (Netherlands)

    Stieger, Bruno; Heger, Michal; de Graaf, Wilmar; Paumgartner, Gustav; van Gulik, Thomas

    2012-01-01

    Liver function tests are of critical importance for the management of patients with severe or terminal liver disease. They are also used as prognostic tools for planning liver resections. In recent years many transport systems have been identified that also transport substances employed in liver

  9. Using Operational Analysis to Improve Access to Pulmonary Function Testing

    Directory of Open Access Journals (Sweden)

    Ada Ip

    2016-01-01

    Full Text Available Background. Timely pulmonary function testing is crucial to improving diagnosis and treatment of pulmonary diseases. Perceptions of poor access at an academic pulmonary function laboratory prompted analysis of system demand and capacity to identify factors contributing to poor access. Methods. Surveys and interviews identified stakeholder perspectives on operational processes and access challenges. Retrospective data on testing demand and resource capacity was analyzed to understand utilization of testing resources. Results. Qualitative analysis demonstrated that stakeholder groups had discrepant views on access and capacity in the laboratory. Mean daily resource utilization was 0.64 (SD 0.15, with monthly average utilization consistently less than 0.75. Reserved testing slots for subspecialty clinics were poorly utilized, leaving many testing slots unfilled. When subspecialty demand exceeded number of reserved slots, there was sufficient capacity in the pulmonary function schedule to accommodate added demand. Findings were shared with stakeholders and influenced scheduling process improvements. Conclusion. This study highlights the importance of operational data to identify causes of poor access, guide system decision-making, and determine effects of improvement initiatives in a variety of healthcare settings. Importantly, simple operational analysis can help to improve efficiency of health systems with little or no added financial investment.

  10. Advanced Grid Support Functionality Testing for Florida Power and Light

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Austin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Martin, Gregory [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hurtt, James [Florida Power and Light, Juno Beach, FL (United States)

    2017-03-21

    This report describes the results of laboratory testing of advanced photovoltaic (PV) inverter testing undertaken by the National Renewable Energy Laboratory (NREL) on behalf of the Florida Power and Light Company (FPL). FPL recently commissioned a 1.1 MW-AC PV installation on a solar carport at the Daytona International Speedway in Daytona Beach, Florida. In addition to providing a source of clean energy production, the site serves as a live test bed with 36 different PV inverters from eight different manufacturers. Each inverter type has varied support for advanced grid support functions (GSFs) that are becoming increasingly commonplace, and are being required through revised interconnection standards such as UL1741, IEEE1547, and California (CA) Rule 21. FPL is interested in evaluating the trade-offs between different GSFs, their compliance to emerging standards, and their effects on efficiency and reliability. NREL has provided a controlled laboratory environment to undertake such a study. This work covered nine different classes of tests to compare inverter capabilities and performance for four different inverters that were selected by FPL. The test inverters were all three-phase models rated between 24-36 kW, and containing multiple PV input power point trackers. Advanced grid support functions were tested for functional behavior, and included fixed power factor operation, voltage-ride through, frequency ride-through, volt-var control, and frequency-Watt control. Response to abnormal grid conditions with GSFs enabled was studied through anti-islanding, fault, and load rejection overvoltage tests. Finally, efficiency was evaluated across a range of operating conditions that included power factor, output power, and input voltage variations. Test procedures were derived from requirements of a draft revision of UL741, CA Rule 21, and/or previous studies at NREL. This reports summarizes the results of each test case, providing a comparative performance analysis

  11. I and C functional test facility user guide

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Ki Chun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-07-01

    The objective of I and C functional test facility (FTF) is to validate newly developed digital control and protection algorithm, alarm reduction algorithm and the function of operator support system and so on. Test facility is divided into three major parts; software, hardware and graphic user interface. Software consists of mathematical modeling which simulates 3 loop pressurizer water reactor, 993 MWe Westinghouse plant and supervisory module which interpret user instructions and data interface program. FTF is implemented in HP747I workstation using FORTRAN77 and ``C`` language under UNIX operating system. This User Guide provides file structure, instructions and program modification method and provides initial data, malfunction list, process variables list and simulation diagram as an appendix to test developed prototype. 12 figs. (Author).

  12. I and C functional test facility user guide

    International Nuclear Information System (INIS)

    Kwon, Ki Chun

    1996-07-01

    The objective of I and C functional test facility (FTF) is to validate newly developed digital control and protection algorithm, alarm reduction algorithm and the function of operator support system and so on. Test facility is divided into three major parts; software, hardware and graphic user interface. Software consists of mathematical modeling which simulates 3 loop pressurizer water reactor, 993 MWe Westinghouse plant and supervisory module which interpret user instructions and data interface program. FTF is implemented in HP747I workstation using FORTRAN77 and ''C'' language under UNIX operating system. This User Guide provides file structure, instructions and program modification method and provides initial data, malfunction list, process variables list and simulation diagram as an appendix to test developed prototype. 12 figs. (Author)

  13. Survey of clinical infant lung function testing practices.

    Science.gov (United States)

    Peterson-Carmichael, Stacey L; Rosenfeld, Margaret; Ascher, Simon B; Hornik, Christoph P; Arets, H G M; Davis, Stephanie D; Hall, Graham L

    2014-02-01

    Data supporting the clinical use of infant lung function (ILF) tests are limited making the interpretation of clinical ILF measures difficult. To evaluate current ILF testing practices and to survey users regarding the indications, limitations and perceived clinical benefits of ILF testing. We created a 26-item survey hosted on the European Respiratory Society (ERS) website between January and May 2010. Notifications were sent to members of the ERS, American Thoracic Society and the Asian Pacific Society of Respirology. Responses were sought from ILF laboratory directors and pediatric respirologists. The survey assessed the clinical indications, patient populations, equipment and reference data used, and perceived limitations of ILF testing. We received 148 responses with 98 respondents having ILF equipment and performing testing in a clinical capacity. Centers in North America were less likely to perform ≥50 studies/year than centers in Europe or other continents (13% vs. 41%). Most respondents used ILF data to either "start a new therapy" (78%) or "help decide about initiation of further diagnostic workup such as bronchoscopy, chest CT or serological testing" (69%). Factors reported as limiting clinical ILF testing were need for sedation, uncertainty regarding clinical impact of study results and time intensive nature of the study. Clinical practices associated with ILF testing vary significantly; centers that perform more studies are more likely to use the results for clinical purposes and decision making. The future of ILF testing is uncertain in the face of the limitations perceived by the survey respondents. © 2013 Wiley Periodicals, Inc.

  14. Reaching the unreached.

    Science.gov (United States)

    Ariyaratne, A T

    1989-01-01

    Embodied in the child survival revolution are ideological, methodological, and organizational innovations aimed at radical change in the condition of the world's children as rapidly as possible. In countries such as Sri Lanka, child survival and health for all by the year 2000 often seem to be impossible goals, given the tumultuous socioeconomic and political conditions. In Sri Lanka, the quality of life has been eroded, not enhanced, by the importation of Western technology and managerial capitalism and the destruction of indigenous processes. The chaos and violence that have been brought into the country have made it difficult to reach the poor children, women, and refugees in rural areas with primary health care interventions. Sri Lanka's unreachable--the decision making elites--have blocked access to the unreached--the urban and rural poor. If governments are to reach the unreached, they must remove the obstacles to a people-centered, community development process. It is the people themselves, and the institutions of their creation, that can reach the children amidst them in greatest need. To achieve this task, local communities must be provided with basic human rights, the power to make decisions that affect their lives, necessary resources, and appropriate technologies. Nongovernmental organizations can play a crucial role as bridges between the unreached and the unreachable by promoting community empowerment, aiding in the formation of networks of community organizations, and establishing linkages with government programs. If the ruling elites in developing countries can be persuaded to accommodate the needs and aspirations of those who, to date, have been excluded from the development process, the child survival revolution can be a nonviolent one.

  15. Solar Hydrogen Reaching Maturity

    Directory of Open Access Journals (Sweden)

    Rongé Jan

    2015-09-01

    Full Text Available Increasingly vast research efforts are devoted to the development of materials and processes for solar hydrogen production by light-driven dissociation of water into oxygen and hydrogen. Storage of solar energy in chemical bonds resolves the issues associated with the intermittent nature of sunlight, by decoupling energy generation and consumption. This paper investigates recent advances and prospects in solar hydrogen processes that are reaching market readiness. Future energy scenarios involving solar hydrogen are proposed and a case is made for systems producing hydrogen from water vapor present in air, supported by advanced modeling.

  16. Reaching Low-Income Mothers to Improve Family Fruit and Vegetable Intake: Food Hero Social Marketing Campaign?Research Steps, Development and Testing

    OpenAIRE

    Tobey, Lauren N.; Koenig, Harold F.; Brown, Nicole A.; Manore, Melinda M.

    2016-01-01

    The objective of this study was to create/test a social marketing campaign to increase fruit/vegetable (FV) intake within Oregon Supplemental Nutrition Assistance Program (SNAP) eligible families. Focus groups (n = 2) and pre/post campaign phone surveys (n = 2082) were conducted in intervention counties (IC) and one control county. Participants were female (86%–100%) with 1–2 children at home. Mean FV intake/without juice was 3.1 servings/day; >50% preferred the Internet for delivery of he...

  17. Utility of dengue NS1 antigen rapid diagnostic test for use in difficult to reach areas and its comparison with dengue NS1 ELISA and qRT-PCR.

    Science.gov (United States)

    Shukla, Mohan K; Singh, Neeru; Sharma, Ravendra K; Barde, Pradip V

    2017-07-01

    The objective of this study was to demonstrate the utility of dengue virus (DENV) non structural protein 1 (NS1) based rapid diagnostic test (RDT) for use in tribal and difficult to reach areas for early dengue (DEN) diagnosis in acute phase patients and evaluate its sensitivity and specificity against DENV NS1 enzyme linked immune sorbent assay (ELISA) and real time reverse transcriptase polymerase chain reaction (qRT-PCR). The DENV NS1 RDT was used for preliminary diagnosis during outbreaks in difficult to reach rural and tribal areas. The diagnosis was confirmed by DENV NS1 ELISA in the laboratory. The samples were also tested and serotyped by qRT-PCR. The results were evaluated using statistical tests. The DENV NS1 RDT showed 99.2% sensitivity and 96.0% specificity when analyzed using DENV NS1 ELISA as standard. The specificity and sensitivity of the RDT when compared with qRT-PCR was 93.6% and 91.1%, respectively. The serotype specific evaluation showed more than 90% sensitivity and specificity for DENV-1, 2, and 3. The RDT proved a good diagnostic tool in difficult to reach rural and tribal areas. Further evaluation studies with different commercially available RDTs in different field conditions are essential, that will help clinicians and patients for treatment and programme managers for timely intervention. © 2017 Wiley Periodicals, Inc.

  18. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    Science.gov (United States)

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the

  19. I and C functional test facility malfunction cause and effect

    International Nuclear Information System (INIS)

    Kwon, Kee Choon.

    1997-06-01

    The objective of I and C function test facility (FTF) is to validate newly developed digital control and protection algorithm, alarm reduction algorithm and the function of operator support system and so on. To realize transient and accident situation in the FTF, the result of the activation of malfunction should be similar to the situation of real nuclear power plants. In this technical report, describe the Group, Malfunction No., Description, Option, Recommendations, Considered in Subroutine, Limitations, Cause, and Effect of the malfunctions implemented in FTF. (author)

  20. Human performance in nondestructive inspections and functional tests: Final report

    International Nuclear Information System (INIS)

    Harris, D.H.

    1988-10-01

    Human performance plays a vital role in the inspections and tests conducted to assure the physical integrity of nuclear power plants. Even when technically-sophisticated equipment is employed, the outcome is highly dependent on human control actions, calibrations, observations, analyses, and interpretations. The principal consequences of inadequate performance are missed or falsely-reported defects. However, the cost-avoidance that stems from addressing potential risks promptly, and the increasing costs likely with aging plants, emphasize that timeliness and efficiency are important inspection-performance considerations also. Human performance issues were studied in a sample of inspections and tests regularly conducted in nuclear power plants. These tasks, selected by an industry advisory panel, were: eddy-current inspection of steam-generator tubes; ultrasonic inspection of pipe welds; inservice testing of pumps and valves; and functional testing of shock suppressors. Information was obtained for the study from industry and plant procedural documents; training materials; research reports and related documents; interviews with training specialists, inspectors, supervisory personnel, and equipment designers; and first-hand observations of task performance. Eleven recommendations are developed for improving human performance on nondestructive inspections and functional tests. Two recommendations were for the more-effective application of existing knowledge; nine recommendations were for research projects that should be undertaken to assure continuing improvements in human performance on these tasks. 25 refs., 9 figs., 1 tab

  1. A Powerful Test for Comparing Multiple Regression Functions.

    Science.gov (United States)

    Maity, Arnab

    2012-09-01

    In this article, we address the important problem of comparison of two or more population regression functions. Recently, Pardo-Fernández, Van Keilegom and González-Manteiga (2007) developed test statistics for simple nonparametric regression models: Y(ij) = θ(j)(Z(ij)) + σ(j)(Z(ij))∊(ij), based on empirical distributions of the errors in each population j = 1, … , J. In this paper, we propose a test for equality of the θ(j)(·) based on the concept of generalized likelihood ratio type statistics. We also generalize our test for other nonparametric regression setups, e.g, nonparametric logistic regression, where the loglikelihood for population j is any general smooth function [Formula: see text]. We describe a resampling procedure to obtain the critical values of the test. In addition, we present a simulation study to evaluate the performance of the proposed test and compare our results to those in Pardo-Fernández et al. (2007).

  2. Reaching Low-Income Mothers to Improve Family Fruit and Vegetable Intake: Food Hero Social Marketing Campaign—Research Steps, Development and Testing

    Science.gov (United States)

    Tobey, Lauren N.; Koenig, Harold F.; Brown, Nicole A.; Manore, Melinda M.

    2016-01-01

    The objective of this study was to create/test a social marketing campaign to increase fruit/vegetable (FV) intake within Oregon Supplemental Nutrition Assistance Program (SNAP) eligible families. Focus groups (n = 2) and pre/post campaign phone surveys (n = 2082) were conducted in intervention counties (IC) and one control county. Participants were female (86%–100%) with 1–2 children at home. Mean FV intake/without juice was 3.1 servings/day; >50% preferred the Internet for delivery of healthy eating information. Participants reported time/financial burdens, low household FV variety and desirability of frozen/canned FV, and acceptance of positive messages. A Food Hero (FH) campaign was created/delivered daily August–October 2009 to mothers through multiple channels (e.g., grocery stores, online, educators). Results showed that the IC had better FH name recall (12%) and interpretation of intended messages (60%) vs. control (3%, 23%, respectively). Compared to controls, the IC were less likely to report healthy food preparation as time consuming or a FV rich diet expensive, and it was easier to get their family to eat fruit. Results did not vary based on county/household characteristics. The FH campaign increased FH awareness and positive FV beliefs. A longer campaign with FV assessments will increase understanding of the target audience, and allow for campaign refinement. PMID:27649233

  3. Reaching Low-Income Mothers to Improve Family Fruit and Vegetable Intake: Food Hero Social Marketing Campaign—Research Steps, Development and Testing

    Directory of Open Access Journals (Sweden)

    Lauren N. Tobey

    2016-09-01

    Full Text Available The objective of this study was to create/test a social marketing campaign to increase fruit/vegetable (FV intake within Oregon Supplemental Nutrition Assistance Program (SNAP eligible families. Focus groups (n = 2 and pre/post campaign phone surveys (n = 2082 were conducted in intervention counties (IC and one control county. Participants were female (86%–100% with 1–2 children at home. Mean FV intake/without juice was 3.1 servings/day; >50% preferred the Internet for delivery of healthy eating information. Participants reported time/financial burdens, low household FV variety and desirability of frozen/canned FV, and acceptance of positive messages. A Food Hero (FH campaign was created/delivered daily August–October 2009 to mothers through multiple channels (e.g., grocery stores, online, educators. Results showed that the IC had better FH name recall (12% and interpretation of intended messages (60% vs. control (3%, 23%, respectively. Compared to controls, the IC were less likely to report healthy food preparation as time consuming or a FV rich diet expensive, and it was easier to get their family to eat fruit. Results did not vary based on county/household characteristics. The FH campaign increased FH awareness and positive FV beliefs. A longer campaign with FV assessments will increase understanding of the target audience, and allow for campaign refinement.

  4. Reaching Low-Income Mothers to Improve Family Fruit and Vegetable Intake: Food Hero Social Marketing Campaign-Research Steps, Development and Testing.

    Science.gov (United States)

    Tobey, Lauren N; Koenig, Harold F; Brown, Nicole A; Manore, Melinda M

    2016-09-13

    The objective of this study was to create/test a social marketing campaign to increase fruit/vegetable (FV) intake within Oregon Supplemental Nutrition Assistance Program (SNAP) eligible families. Focus groups (n = 2) and pre/post campaign phone surveys (n = 2082) were conducted in intervention counties (IC) and one control county. Participants were female (86%-100%) with 1-2 children at home. Mean FV intake/without juice was 3.1 servings/day; >50% preferred the Internet for delivery of healthy eating information. Participants reported time/financial burdens, low household FV variety and desirability of frozen/canned FV, and acceptance of positive messages. A Food Hero (FH) campaign was created/delivered daily August-October 2009 to mothers through multiple channels (e.g., grocery stores, online, educators). Results showed that the IC had better FH name recall (12%) and interpretation of intended messages (60%) vs. control (3%, 23%, respectively). Compared to controls, the IC were less likely to report healthy food preparation as time consuming or a FV rich diet expensive, and it was easier to get their family to eat fruit. Results did not vary based on county/household characteristics. The FH campaign increased FH awareness and positive FV beliefs. A longer campaign with FV assessments will increase understanding of the target audience, and allow for campaign refinement.

  5. BROOKHAVEN: Proton goal reached

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    On March 30 the 35-year old Alternating Gradient Synchrotron (AGS) exceeded its updated design goal of 6 x 10 13 protons per pulse (ppp), by accelerating 6.3 x 10 13 ppp, a world record intensity. This goal was set 11 years ago and achieving it called for the construction of a new booster and the reconstruction of much of the AGS. The booster was completed in 1991, and reached its design intensity of 1.5 x 10 13 ppp in 1993. The AGS reconstruction was finished in 1994, and by July of that year the AGS claimed a new US record intensity for a proton synchrotron of 4 x 10 13 ppp, using four booster pulses. Reaching the design intensity was scheduled for 1995. In 1994, the AGS had seemed to be solidly limited to 4 x 10 13 ppp, but in 1995 the operations crew, working on their own in the quiet of the owl shift, steadily improved the intensity, regularly setting new records, much to the bemusement of the machine physicists. The physicists, however, did contribute. A second harmonic radiofrequency cavity in the booster increased the radiofrequency bucket area for capture, raising the booster intensity from 1.7 to 2.1 x 10 13 ppp. In the AGS, new radiofrequency power supplies raised the available voltage from 8 to 13 kV, greatly enhancing the beam loading capabilities of the system. A powerful new transverse damping system successfully controlled instabilities that otherwise would have destroyed the beam in less than a millisecond. Also in the AGS, 35th harmonic octupole resonances were found

  6. BROOKHAVEN: Proton goal reached

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1995-09-15

    On March 30 the 35-year old Alternating Gradient Synchrotron (AGS) exceeded its updated design goal of 6 x 10{sup 13} protons per pulse (ppp), by accelerating 6.3 x 10{sup 13} ppp, a world record intensity. This goal was set 11 years ago and achieving it called for the construction of a new booster and the reconstruction of much of the AGS. The booster was completed in 1991, and reached its design intensity of 1.5 x 10{sup 13} ppp in 1993. The AGS reconstruction was finished in 1994, and by July of that year the AGS claimed a new US record intensity for a proton synchrotron of 4 x 10{sup 13} ppp, using four booster pulses. Reaching the design intensity was scheduled for 1995. In 1994, the AGS had seemed to be solidly limited to 4 x 10{sup 13} ppp, but in 1995 the operations crew, working on their own in the quiet of the owl shift, steadily improved the intensity, regularly setting new records, much to the bemusement of the machine physicists. The physicists, however, did contribute. A second harmonic radiofrequency cavity in the booster increased the radiofrequency bucket area for capture, raising the booster intensity from 1.7 to 2.1 x 10{sup 13} ppp. In the AGS, new radiofrequency power supplies raised the available voltage from 8 to 13 kV, greatly enhancing the beam loading capabilities of the system. A powerful new transverse damping system successfully controlled instabilities that otherwise would have destroyed the beam in less than a millisecond. Also in the AGS, 35th harmonic octupole resonances were found.

  7. Test Protocols for Advanced Inverter Interoperability Functions - Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ralph, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not now required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already apparent as

  8. Test Protocols for Advanced Inverter Interoperability Functions – Main Document

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Jay Dean [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gonzalez, Sigifredo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ralph, Mark E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Broderick, Robert Joseph [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2013-11-01

    Distributed energy resources (DER) such as photovoltaic (PV) systems, when deployed in a large scale, are capable of influencing significantly the operation of power systems. Looking to the future, stakeholders are working on standards to make it possible to manage the potentially complex interactions between DER and the power system. In 2009, the Electric Power Research Institute (EPRI), Sandia National Laboratories (SNL) with the U.S. Department of Energy (DOE), and the Solar Electric Power Association (SEPA) initiated a large industry collaborative to identify and standardize definitions for a set of DER grid support functions. While the initial effort concentrated on grid-tied PV inverters and energy storage systems, the concepts have applicability to all DER. A partial product of this on-going effort is a reference definitions document (IEC TR 61850-90-7, Object models for power converters in distributed energy resources (DER) systems) that has become a basis for expansion of related International Electrotechnical Commission (IEC) standards, and is supported by US National Institute of Standards and Technology (NIST) Smart Grid Interoperability Panel (SGIP). Some industry-led organizations advancing communications protocols have also embraced this work. As standards continue to evolve, it is necessary to develop test protocols to independently verify that the inverters are properly executing the advanced functions. Interoperability is assured by establishing common definitions for the functions and a method to test compliance with operational requirements. This document describes test protocols developed by SNL to evaluate the electrical performance and operational capabilities of PV inverters and energy storage, as described in IEC TR 61850-90-7. While many of these functions are not currently required by existing grid codes or may not be widely available commercially, the industry is rapidly moving in that direction. Interoperability issues are already

  9. 131I-BSP liver function test by BSP tolerance

    International Nuclear Information System (INIS)

    Kanda, Koichi

    1974-01-01

    131 I-BSP liver function test after BSP intravenous tolerance was discussed, assuming that the reason why measurements of 131 I-BSP retention rate at 30 minutes and 131 I-BSP disappearance rate in blood showed respectable overlapping between normal group and group with slight liver disorders as compared with BSP test and the reason why differential diagnosis was difficult were due to underestimate of tolerance volume of 131 I-BSP. 131 I-BSP was observed with time as to 70 persons with normal liver function and 257 cases of liver diseases, using 5, 3 and 2 mg of non-radioactive BSP tolerance volume per kilogram of body weight. 131 I-BSP retention rate at 30 minutes and 131 I-BSP disappearance rate in blood are possible to separate overlapping over control in each measurement value at 3-5 mg/kg of tolerance, and in comparison of 3 mg and 5 mg, the latter showed a little excellent result. So, it was decided that tolerance of 3 mg/kg was a proper dose, considering tolerance to liver cells. 131 I-BSP retention rate at 30 minutes was a little excellent in accuracy and disappearance rate in blood after BSP tolerance is simple and profitable for practical use because collection of blood was only one time and measurement could be made with whole blood. As mentioned above, this method is seemed to be useful to practice of liver function test. (Kanao, N.)

  10. The partial coherence modulation transfer function in testing lithography lens

    Science.gov (United States)

    Huang, Jiun-Woei

    2018-03-01

    Due to the lithography demanding high performance in projection of semiconductor mask to wafer, the lens has to be almost free in spherical and coma aberration, thus, in situ optical testing for diagnosis of lens performance has to be established to verify the performance and to provide the suggesting for further improvement of the lens, before the lens has been build and integrated with light source. The measurement of modulation transfer function of critical dimension (CD) is main performance parameter to evaluate the line width of semiconductor platform fabricating ability for the smallest line width of producing tiny integrated circuits. Although the modulation transfer function (MTF) has been popularly used to evaluation the optical system, but in lithography, the contrast of each line-pair is in one dimension or two dimensions, analytically, while the lens stand along in the test bench integrated with the light source coherent or near coherent for the small dimension near the optical diffraction limit, the MTF is not only contributed by the lens, also by illumination of platform. In the study, the partial coherence modulation transfer function (PCMTF) for testing a lithography lens is suggested by measuring MTF in the high spatial frequency of in situ lithography lens, blended with the illumination of partial and in coherent light source. PCMTF can be one of measurement to evaluate the imperfect lens of lithography lens for further improvement in lens performance.

  11. Pheochromocytoma with Markedly Abnormal Liver Function Tests and Severe Leukocytosis

    Directory of Open Access Journals (Sweden)

    Chai Ryoung Eun

    2014-03-01

    Full Text Available Pheochromocytoma is a rare neuroendocrine tumor arising from the medulla of the adrenal glands, which causes an overproduction of catecholamines. The common symptoms are headache, palpitations, and sweating; however, various other clinical manifestations might also be present. Accurate diagnosis of pheochromocytoma is important because surgical treatment is usually successful, and associated clinical problems are reversible if treated early. A 49-year-old man with a history of uncontrolled hypertension and diabetes mellitus presented with chest pain, fever, and sweating. His liver function tests and white blood cell counts were markedly increased and his echocardiography results suggested stress-induced cardiomyopathy. His abdominal computed tomography showed a 5×5-cm-sized tumor in the left adrenal gland, and laboratory tests confirmed catecholamine overproduction. After surgical resection of the left adrenal gland, his liver function tests and white blood cell counts normalized, and echocardiography showed normal cardiac function. Moreover, his previous antihypertensive regimen was deescalated, and his previously uncontrolled blood glucose levels normalized without medication.

  12. The development of functional requirement for integrated test facility

    International Nuclear Information System (INIS)

    Sim, B.S.; Oh, I.S.; Cha, K.H.; Lee, H.C.

    1994-01-01

    An Integrated Test Facility (ITF) is a human factors experimental environment comprised of a nuclear power plant function simulator, man-machine interfaces (MMI), human performance recording systems, and signal control and data analysis systems. In this study, we are going to describe how the functional requirements are developed by identification of both the characteristics of generic advanced control rooms and the research topics of world-wide research interest in human factors community. The functional requirements of user interface developed in this paper together with those of the other elements will be used for the design and implementation of the ITF which will serve as the basis for experimental research on a line of human factors topics. (author). 15 refs, 1 fig

  13. Test Ability of Chiller Post Re-functioning at The Facility of KH-IPSB3

    International Nuclear Information System (INIS)

    Harahap, Sentot-Alibasya; M-Taufik-Arsyad; Djunaidi

    2006-01-01

    Chiller water unit (CWU) represent supplier of cool water for the system of ventilation, cooler of purification system irrigate canal (T.C) and pool (depository ponds) ex-fuel at facility of KH-IPSB3. Have been conducted by re-functioning of Chiller unit water by changing system conduct and control from electronic mode to mode of electric-mechanic and parts of damage other. A unit water chiller system have some component / appliance which way of its activity integrated one other, so that re-functioning of partial like in this time where some of component / appliance use old goods and some of using new material hence to get optimum activity at test ability of difficult chiller relative. At operation is old ones expected by optimum activity will be able to reach with an process which in phases and planed. (author)

  14. Reaching Beyond The Stars

    Science.gov (United States)

    Baker, Mariah; Rosenthal, L.; Gaughan, A.; Hopkins, E.

    2014-01-01

    Strawbridge Observatory at Haverford College is home to a undergraduate-led public observing program. Our program holds ~once monthly public events throughout the academic year that take advantage of eyepiece observing on our 16-inch and 12-inch telescopes as well as of the classroom, library, and projection system. These resources allow us to organize a variety of astronomy related activities that are engaging for individuals of all ages: accessible student talks, current film screenings and even arts and crafts for the families who attend with young children. These events aim to spark curiosity in others about scientific discovery and about the remarkable nature of the world in which we live. In addition to exciting local families about astronomy, this program has excited Haverford students from a range of disciplines about both science and education. Being entirely student led means that we are able to take the initiative in planning, coordinating and running all events, fostering an atmosphere of collaboration, experimentation and commitment amongst our volunteers. Additionally, this program is one of the few at Haverford that regularly reaches beyond the campus walls to promote and build relationships with the outside community. In light of this, our program presents a distinctive and enlightening opportunity for student volunteers: we get to use our scientific backgrounds to educate a general audience, while also learning from them about how to communicate and inspire in others the excitement we feel about the subject of astronomy. The work on this project has been supported by NSF AST-1151462.

  15. GAP-REACH

    Science.gov (United States)

    Lewis-Fernández, Roberto; Raggio, Greer A.; Gorritz, Magdaliz; Duan, Naihua; Marcus, Sue; Cabassa, Leopoldo J.; Humensky, Jennifer; Becker, Anne E.; Alarcón, Renato D.; Oquendo, María A.; Hansen, Helena; Like, Robert C.; Weiss, Mitchell; Desai, Prakash N.; Jacobsen, Frederick M.; Foulks, Edward F.; Primm, Annelle; Lu, Francis; Kopelowicz, Alex; Hinton, Ladson; Hinton, Devon E.

    2015-01-01

    Growing awareness of health and health care disparities highlights the importance of including information about race, ethnicity, and culture (REC) in health research. Reporting of REC factors in research publications, however, is notoriously imprecise and unsystematic. This article describes the development of a checklist to assess the comprehensiveness and the applicability of REC factor reporting in psychiatric research publications. The 16-itemGAP-REACH© checklist was developed through a rigorous process of expert consensus, empirical content analysis in a sample of publications (N = 1205), and interrater reliability (IRR) assessment (N = 30). The items assess each section in the conventional structure of a health research article. Data from the assessment may be considered on an item-by-item basis or as a total score ranging from 0% to 100%. The final checklist has excellent IRR (κ = 0.91). The GAP-REACH may be used by multiple research stakeholders to assess the scope of REC reporting in a research article. PMID:24080673

  16. UX-15 Reaches LEP

    CERN Multimedia

    2001-01-01

    The creation of the world's largest sandstone cavern, not a small feat! At the bottom, cave-in preventing steel mesh can be seen clinging to the top of the tunnel. The digging of UX-15, the cavern that will house ATLAS, reached the upper ceiling of LEP on October 10th. The breakthrough which took place nearly 100 metres underground occurred precisely on schedule and exactly as planned. But much caution was taken beforehand to make the LEP breakthrough clean and safe. To prevent the possibility of cave-ins in the side tunnels that will eventually be attached to the completed UX-15 cavern, reinforcing steel mesh was fixed into the walls with bolts. Obviously no people were allowed in the LEP tunnels below UX-15 as the breakthrough occurred. The area was completely evacuated and fences were put into place to keep all personnel out. However, while personnel were being kept out of the tunnels below, this has been anything but the case for the work taking place up above. With the creation of the world's largest...

  17. Measurement of Function Post Hip Fracture: Testing a Comprehensive Measurement Model of Physical Function.

    Science.gov (United States)

    Resnick, Barbara; Gruber-Baldini, Ann L; Hicks, Gregory; Ostir, Glen; Klinedinst, N Jennifer; Orwig, Denise; Magaziner, Jay

    2016-07-01

    Measurement of physical function post hip fracture has been conceptualized using multiple different measures. This study tested a comprehensive measurement model of physical function. This was a descriptive secondary data analysis including 168 men and 171 women post hip fracture. Using structural equation modeling, a measurement model of physical function which included grip strength, activities of daily living, instrumental activities of daily living, and performance was tested for fit at 2 and 12 months post hip fracture, and among male and female participants. Validity of the measurement model of physical function was evaluated based on how well the model explained physical activity, exercise, and social activities post hip fracture. The measurement model of physical function fit the data. The amount of variance the model or individual factors of the model explained varied depending on the activity. Decisions about the ideal way in which to measure physical function should be based on outcomes considered and participants. The measurement model of physical function is a reliable and valid method to comprehensively measure physical function across the hip fracture recovery trajectory. © 2015 Association of Rehabilitation Nurses.

  18. Reference values for paediatric pulmonary function testing: The Utrecht dataset.

    Science.gov (United States)

    Koopman, Marije; Zanen, Pieter; Kruitwagen, Cas L J J; van der Ent, Cornelis K; Arets, Hubertus G M

    2011-01-01

    Since populations evolve, measurement protocols and equipment improve and analysis techniques progress, there is an ongoing need to reassess reference data for pulmonary function tests. Furthermore, reference values for total lung capacity and carbon monoxide diffusion capacity are scarcely available in children. We aimed to provide updated reference equations for most commonly used pulmonary function indices in Caucasian children. In the 'Utrecht Pulmonary Function Reference Data Study' we collected data in Caucasian children aged 2-18 years. We analyzed them using the 'Generalized Additive Models for Location Scale and Shape' (GAMLSS) statistical method. Measurements of interrupter resistance (R(int)) (n = 877), spirometry (n = 1042), body plethysmography (n = 723) and carbon monoxide diffusion/helium dilution (n = 543) were obtained in healthy children. Height (or the natural logarithm of height) and age (or the natural logarithm of age) were both significantly related to most outcome measures. Also sex was a significant determinant, except for RV, RV/TLC, FRC(pleth), Raw(0,5), Raw(tot), R(int) and FEF values. The application of previously published reference equations on the study population resulted in misinterpretation of pulmonary function. These new paediatric reference equations provide accurate estimates of the range of normality for most commonly used pulmonary function indices, resulting in less underdiagnosis and overdiagnosis of pulmonary diseases. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Thyroid function testing in neonates born to women with hypothyroidism.

    Science.gov (United States)

    McGovern, Matthew; Reyani, Zahra; O'Connor, Pamela; White, Martin; Miletin, Jan

    2016-12-01

    Our aim was to assess the utility of serum thyroxine and thyroid stimulating hormone performed at 10-14 days of life in diagnosing congenital hypothyroidism (CH) in babies born to mothers with hypothyroidism. This was a retrospective study of all babies born in a tertiary referral centre for neonatology over a 12-month period. Infants who had thyroid function testing (TFT) checked at 10-14 days of life because of maternal hypothyroidism during the period of study were included. The results of the newborn bloodspot and day 10-14 TFT were recorded along with whether or not patients were subsequently treated. Of the 319 patients included in the study, only two patients were found to have CH and in both cases the newborn blood spot had been abnormal. No extra cases of CH were detected from the thyroid test at 10-14 days and this practice should be discontinued due to the robust nature of existing newborn screening programmes. What is Known: • Congenital hypothyroidism(CH) is the commonest preventable cause of childhood intellectual impairment. • Family history of hypothyroidism has been implicated as a risk factor for CH. • CH has formed part of newborn screening since the 1970s. What is New: • There is no research recommending thyroid function testing at 10-14 days of life to detect CH in neonates born to mothers with hypothyroidism. • Thyroid function testing at 10-14 days of life does not improve diagnostic yield for CH in babies born to mothers with hypothyroidism. • Newborn blood spot remains the mainstay for accurate and timely diagnosis of CH.

  20. REACH: Evaluation Report and Executive Summary

    Science.gov (United States)

    Sibieta, Luke

    2016-01-01

    REACH is a targeted reading support programme designed to improve reading accuracy and comprehension in pupils with reading difficulties in Years 7 and 8. It is based on research by the Centre for Reading and Language at York and is delivered by specially trained teaching assistants (TAs). This evaluation tested two REACH interventions, one based…

  1. Effects of Differential Item Functioning on Examinees' Test Performance and Reliability of Test

    Science.gov (United States)

    Lee, Yi-Hsuan; Zhang, Jinming

    2017-01-01

    Simulations were conducted to examine the effect of differential item functioning (DIF) on measurement consequences such as total scores, item response theory (IRT) ability estimates, and test reliability in terms of the ratio of true-score variance to observed-score variance and the standard error of estimation for the IRT ability parameter. The…

  2. Structure of four executive functioning tests in healthy older adults.

    Science.gov (United States)

    de Frias, Cindy M; Dixon, Roger A; Strauss, Esther

    2006-03-01

    The authors examined the factor structure of 4 indicators of executive functioning derived from 2 new (i.e., Hayling and Brixton) and 2 traditional (i.e., Stroop and Color Trails) tests. Data were from a cross-sectional sample of 55- to 85-year-old healthy adults (N=427) from the Victoria Longitudinal Study. Confirmatory factor analysis (LISREL 8.52) tested both a 2-factor model of Inhibition (Hayling, Stroop) and Shifting (Brixton, Color Trails) and a single-factor model. The 2-factor model did not fit the data because the covariance matrix of the factors was not positive definite. The single-factor model fit the data well, chi(2)(2, N=427)=0.32, p=.85, root-mean-square error of approximation (RMSEA)=.00, comparative fit index (CFI)=1.00, goodness-of-fit index (GFI)=1.00. Moreover, the single-factor structure of executive functioning was invariant (configural and metric) across gender, and invariant (configural with limited metric) across age. Structural relations showed that poorer executive functioning performance was related to older age and lower fluid intelligence, chi(2)(11, N=418)=23.04, p=.02, RMSEA=.05, CFI=.97, GFI=.98.

  3. Staging chronic pancreatitis with exocrine function tests: Are we better?

    Science.gov (United States)

    Sperti, Cosimo; Moletta, Lucia

    2017-10-14

    Chronic pancreatitis (CP) is an inflammatory disease of the pancreas evolving in progressive fibrotic disruption of the gland with exocrine and endocrine pancreatic insufficiency. Although imaging features of CP are well known, their correlation with exocrine pancreatic function tests are not obvious, particularly in the early stage of the disease. There are many clinical classification of CP, all suggested for better distinguish and manage different forms based on etiological and clinical factors, and severity of the disease. Recently, a new classification of CP has been suggested: the M-ANNHEIM multiple risk factor classification that includes etiology, stage classification and degree of clinical severity. However, more accurate determination of clinical severity of CP requires a correct determination of exocrine function of the pancreas and fecal fat excretion. Recently, Kamath et al demonstrated that the evaluation of exocrine pancreatic function by acid steatocrit and fecal elastase-1 (EF-1) was helpful, but EF-1 was able to detect exocrine pancreatic insufficiency in more patients, upgrading some patients in higher stage of disease according to M-ANNHEIM classification. So, EF-1 is a more accurate test to determine exocrine pancreatic insufficiency and to stage chronic pancreatitis in the M-ANNHEIM classification. On the contrary, EF-1 determination shows low sensitivity in detecting exocrine pancreatic insufficiency in early stage of the disease.

  4. Validation of Cardiovascular Parameters during NASA's Functional Task Test

    Science.gov (United States)

    Arzeno, N. M.; Stenger, M. B.; Bloomberg, J. J.; Platts, S. H.

    2009-01-01

    Microgravity exposure causes physiological deconditioning and impairs crewmember task performance. The Functional Task Test (FTT) is designed to correlate these physiological changes to performance in a series of operationally-relevant tasks. One of these, the Recovery from Fall/Stand Test (RFST), tests both the ability to recover from a prone position and cardiovascular responses to orthostasis. PURPOSE: Three minutes were chosen for the duration of this test, yet it is unknown if this is long enough to induce cardiovascular responses similar to the operational 5 min stand test. The purpose of this study was to determine the validity and reliability of heart rate variability (HRV) analysis of a 3 min stand and to examine the effect of spaceflight on these measures. METHODS: To determine the validity of using 3 vs. 5 min of standing to assess HRV, ECG was collected from 7 healthy subjects who participated in a 6 min RFST. Mean R-R interval (RR) and spectral HRV were measured in minutes 0-3 and 0-5 following the heart rate transient due to standing. Significant differences between the segments were determined by a paired t-test. To determine the reliability of the 3-min stand test, 13 healthy subjects completed 3 trials of the FTT on separate days, including the RFST with a 3 min stand. Analysis of variance (ANOVA) was performed on the HRV measures. One crewmember completed the FTT before a 14-day mission, on landing day (R+0) and one (R+1) day after returning to Earth. RESULTS VALIDITY: HRV measures reflecting autonomic activity were not significantly different during the 0-3 and 0-5 min segments. RELIABILITY: The average coefficient of variation for RR, systolic (SBP) and diastolic blood pressures during the RFST were less than 8% for the 3 sessions. ANOVA results yielded a greater inter-subject variability (p0.05) for HRV in the RFST. SPACEFLIGHT: Lower RR and higher SBP were observed on R+0 in rest and stand. On R+1, both RR and SBP trended towards preflight

  5. Reliability of a Functional Test Battery Evaluating Functionality, Proprioception and Strength of the Ankle Joint

    OpenAIRE

    YILDIZ, Yavuz; ŞEKİR, Ufuk; HAZNECİ, Bülent

    2009-01-01

    Aim: In contrast to the one-sided evaluation methods used in the past, combining multiple tests allows one to obtain a global assessment of the ankle joint. Materials and Methods: Twenty healthy male volunteers participated in this study. One component of the test battery included five different functional ability tests, which included: single limb hopping course, one-legged and triple-legged hop for distance, and six-meter (6-m) and cross 6-m hop for time. Ankle joint position sense and on...

  6. Testing intermolecular potential functions using transport property data

    International Nuclear Information System (INIS)

    Clifford, A.A.; Dickinson, E.; Gray, P.; Scott, A.C.

    1975-01-01

    The viscosity of hydrogen has been measured at eight temperatures from 273 to 1060K, using a capillary-flow viscometer. The results have been used to test the repulsive part of a recently formulated H 2 /H 2 intermolecular potential function, obtained from molecular-beam measurements. Agreement between the experimental and predicted values for viscosity is within 3.5%, which corresponds approximately to the combined quoted uncertainties in the two sets of data. However, if the value of the distance parameter of the potential is reduced by about 1.5%, the agreement obtained is within 0.75% over the whole temperature range. This modified potential function gives better agreement with the available higher temperature viscosities and second virial coefficients. (author)

  7. Assessing Differential Item Functioning on the Test of Relational Reasoning

    Directory of Open Access Journals (Sweden)

    Denis Dumas

    2018-03-01

    Full Text Available The test of relational reasoning (TORR is designed to assess the ability to identify complex patterns within visuospatial stimuli. The TORR is designed for use in school and university settings, and therefore, its measurement invariance across diverse groups is critical. In this investigation, a large sample, representative of a major university on key demographic variables, was collected, and the resulting data were analyzed using a multi-group, multidimensional item-response theory model-comparison procedure. No significant differential item functioning was found on any of the TORR items across any of the demographic groups of interest. This finding is interpreted as evidence of the cultural fairness of the TORR, and potential test-development choices that may have contributed to that cultural fairness are discussed.

  8. Compact muon solenoid magnet reaches full field

    CERN Multimedia

    2006-01-01

    Scientist of the U.S. Department of Energy in Fermilab and collaborators of the US/CMS project announced that the world's largest superconducting solenoid magnet has reached full field in tests at CERN. (1 apge)

  9. A virtual shopping test for realistic assessment of cognitive function.

    Science.gov (United States)

    Okahashi, Sayaka; Seki, Keiko; Nagano, Akinori; Luo, Zhiwei; Kojima, Maki; Futaki, Toshiko

    2013-06-18

    Cognitive dysfunction caused by brain injury often prevents a patient from achieving a healthy and high quality of life. By now, each cognitive function is assessed precisely by neuropsychological tests. However, it is also important to provide an overall assessment of the patients' ability in their everyday life. We have developed a Virtual Shopping Test (VST) using virtual reality technology. The objective of this study was to clarify 1) the significance of VST by comparing VST with other conventional tests, 2) the applicability of VST to brain-damaged patients, and 3) the performance of VST in relation to age differences. The participants included 10 patients with brain damage, 10 age-matched healthy subjects for controls, 10 old healthy subjects, and 10 young healthy subjects. VST and neuropsychological tests/questionnaires about attention, memory and executive function were conducted on the patients, while VST and the Mini-Mental State Examination (MMSE) were conducted on the controls and healthy subjects. Within the VST, the participants were asked to buy four items in the virtual shopping mall quickly in a rational way. The score for evaluation included the number of items bought correctly, the number of times to refer to hints, the number of movements between shops, and the total time spent to complete the shopping. Some variables on VST correlated with the scores of conventional assessment about attention and everyday memory. The mean number of times referring to hints and the mean number of movements were significantly larger for the patients with brain damage, and the mean total time was significantly longer for the patients than for the controls. In addition, the mean total time was significantly longer for the old than for the young. The results suggest that VST is able to evaluate the ability of attention and everyday memory in patients with brain damage. The time of VST is increased by age.

  10. Tests of pancreatic function using /sup 75/Se--Selenomethionine

    Energy Technology Data Exchange (ETDEWEB)

    Krasner, N; Brodie, M J; Sumner, D J; Thomson, T J

    1976-04-01

    Pancreatic function was investigated in 43 patients using a combination of conventional and subtraction scans of the pancreas and duodenal aspiration of the /sup 75/Se-Selenomethionine injected, in the time periods 60 to 150 minutes, 90 to 120 minutes and 105 to 150 minutes after injection. Patients with chronic alcoholism, chronic pancreatitis, pancreatic carcinoma, extrahepatic biliary obstruction and liver disease were included. Seven patients with no evidence of gastro-intestinal disease served as controls. Pancreatic scanning provided eight false positive and two false negative results (23.3 percent) and with /sup 75/Se-Selenomethionine excretion at 105 to 150 minutes, six false results were obtained (14 percent). In only one patient was a false positive result obtained with both scans and the /sup 75/Se-Selenomethionine test. The performance of conventional and subtraction scans of the pancreas with measurement of /sup 75/Se-Selenomethionine activity in the duodenal aspirate collected from 105 to 150 minutes after injection provides a convenient means of testing pancreatic exocrine function in a single three hour session.

  11. Production of functional sperm by subcutaneous auto-grafting of immature testes in rainbow trout.

    Science.gov (United States)

    Hayashi, Makoto; Sakuma, Daika; Yoshizaki, Goro

    2018-02-01

    Sexually mature individuals are indispensable for breeding programs. Salmonids require a long period before reaching sexual maturity, so we aimed to shorten the period required to obtain functional sperm by grafting immature testicular fragments into mature recipients, which we predicted would allow the grafted testicular fragments to skip the long pre-pubertal period. First, we demonstrated successful subcutaneous auto-grafting of testicular fragments in rainbow trout. Unilateral testectomy was performed, and the isolated immature testicular fragment was auto-grafted into the subcutaneous space along the back of recipient fish. The grafted testicular fragments developed synchronously with the recipients' testis remaining in its body cavity, and both eventually produced functional sperm. Next, immature testicular fragments were auto-grafted into the subcutaneous space of sexually mature males. We achieved this, without immune rejection, by isolating and cryopreserving testes from immature fish, and rearing these unilaterally testectomized fish until sexual maturity. The cryopreserved testes were then auto-grafted into the original, now spermiating fish. The grated immature testicular fragments differentiated and produced functional sperm within 5 months after grafting. By combining this grafting method with a technique to avoid immune rejection, we expect to develop a practical method for producing sperm in a shorter period in salmonids. © 2017 Wiley Periodicals, Inc.

  12. [TCD functional test for vertigo induced by ischemic cerebrovascular disorders].

    Science.gov (United States)

    Li, Q; Zhong, N; Xue, X

    1999-04-01

    To diagnose differentially the vetigo induced by some ischemic cerebrovascular disorder. Patients with vertebrobasilar artery transient ischemic vertigo (group A), migraine (group B), hyperventilation syndrome (group C), hypertension (group D) are measured by using TCD functional examination which included blood peak velocity of systolic (Vs) and diastolic (Vd) end-period of vertibrobasilar artery of routine TCD (TCD-R), one minute hyperventilation TCD (TCD-HV) and one minute voluntary apnea TCD (TCD-B) respectively. It showed that the Vs, Vd are decreased under the three conditions in A, B and D groups. The most apparent decrease are obversed in D group. The values of the decrease are similar between group A and B. No changes are found in C group. The abnormal Vs incidences of TCD-B measurement in group A are higher than those in group B and C, but significant lower than those in group D; and in TCD-HV test lower than group D and C, higher than group B; in TCD-R test, lower than group D, and no difference with group B and C. The abnormal incidences of Vd in group A are lower than group D and higher than group B in TCD-B test. In TCD-HV test, the group A abnormol incidences are lower than group D but higher than group B and C. In TCD-R test, the abnormal incidences are lower than group D and no difference between group B and C. The TCD measuremen is useful for differential diagnosis of vertigo induced by ischemic cerebrovascular disorders.

  13. Functional toxicology: tools to advance the future of toxicity testing

    Science.gov (United States)

    Gaytán, Brandon D.; Vulpe, Chris D.

    2014-01-01

    The increased presence of chemical contaminants in the environment is an undeniable concern to human health and ecosystems. Historically, by relying heavily upon costly and laborious animal-based toxicity assays, the field of toxicology has often neglected examinations of the cellular and molecular mechanisms of toxicity for the majority of compounds—information that, if available, would strengthen risk assessment analyses. Functional toxicology, where cells or organisms with gene deletions or depleted proteins are used to assess genetic requirements for chemical tolerance, can advance the field of toxicity testing by contributing data regarding chemical mechanisms of toxicity. Functional toxicology can be accomplished using available genetic tools in yeasts, other fungi and bacteria, and eukaryotes of increased complexity, including zebrafish, fruit flies, rodents, and human cell lines. Underscored is the value of using less complex systems such as yeasts to direct further studies in more complex systems such as human cell lines. Functional techniques can yield (1) novel insights into chemical toxicity; (2) pathways and mechanisms deserving of further study; and (3) candidate human toxicant susceptibility or resistance genes. PMID:24847352

  14. Grammar tests increase the ability to lateralize language function in the Wada test.

    Science.gov (United States)

    Połczyńska, Monika; Curtiss, Susan; Walshaw, Particia; Siddarth, Prabha; Benjamin, Chris; Moseley, Brian D; Vigil, Celia; Jones, Michael; Eliashiv, Dawn; Bookheimer, Susan

    2014-12-01

    Grammar is a core component of the language system, yet it is rarely assessed during the Wada (intracarotid amobarbital) test. It is hypothesized that adding grammar tests to the recovery phase of the Wada test will increase our ability to lateralize language function. Sixteen individuals (nine females, fifteen right-handed, mean age 38.4 years, SD=10.7) with medically refractory temporal lobe epilepsy participated in the study. On EEG ten patients had seizures originating in the left hemisphere (LH), five in the right hemisphere (RH), and one was insufficiently lateralized. We included only patients who were LH-dominant on the standard test in the encoding phase of the Wada test. In the recovery phase of Wada testing the participants underwent evaluation with a standard language and a new test of grammar, the CYCLE-N. Ten patients underwent bilateral injections, six unilateral (one RH, five LH). As expected, injection in the LH decreased language performance to a greater extent than injection to the RH on both tests. However, the CYCLE-N produced more profound language deficits in the injected LH compared to the RH (p=0.01), whereas the standard tests did not cause such pronounced differences (p=0.2). The results suggest that the standard tests did not significantly differentiate the effects of the injections and the CYCLE-N, for the most part, did. Our results are of particular relevance to patients who are too obtunded to speak in the encoding phase. In sum, the CYCLE-N may be helpful in assessing hemispheric dominance for language. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Utility and reliability of non-invasive muscle function tests in high-fat-fed mice.

    Science.gov (United States)

    Martinez-Huenchullan, Sergio F; McLennan, Susan V; Ban, Linda A; Morsch, Marco; Twigg, Stephen M; Tam, Charmaine S

    2017-07-01

    What is the central question of this study? Non-invasive muscle function tests have not been validated for use in the study of muscle performance in high-fat-fed mice. What is the main finding and its importance? This study shows that grip strength, hang wire and four-limb hanging tests are able to discriminate the muscle performance between chow-fed and high-fat-fed mice at different time points, with grip strength being reliable after 5, 10 and 20 weeks of dietary intervention. Non-invasive tests are commonly used for assessing muscle function in animal models. The value of these tests in obesity, a condition where muscle strength is reduced, is unclear. We investigated the utility of three non-invasive muscle function tests, namely grip strength (GS), hang wire (HW) and four-limb hanging (FLH), in C57BL/6 mice fed chow (chow group, n = 48) or a high-fat diet (HFD group, n = 48) for 20 weeks. Muscle function tests were performed at 5, 10 and 20 weeks. After 10 and 20 weeks, HFD mice had significantly reduced GS (in newtons; mean ± SD: 10 weeks chow, 1.89 ± 0.1 and HFD, 1.79 ± 0.1; 20 weeks chow, 1.99 ± 0.1 and HFD, 1.75 ± 0.1), FLH [in seconds per gram body weight; median (interquartile range): 10 weeks chow, 2552 (1337-4964) and HFD, 1230 (749-1994); 20 weeks chow, 2048 (765-3864) and HFD, 1036 (717-1855)] and HW reaches [n; median (interquartile range): 10 weeks chow, 4 (2-5) and HFD, 2 (1-3); 20 weeks chow, 3 (1-5) and HFD, 1 (0-2)] and higher falls [n; median (interquartile range): 10 weeks chow, 0 (0-2) and HFD, 3 (1-7); 20 weeks chow, 1 (0-4) and HFD, 8 (5-10)]. Grip strength was reliable in both dietary groups [intraclass correlation coefficient (ICC) = 0.5-0.8; P tests are valuable and reliable tools for assessment of muscle strength and function in high-fat-fed mice. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.

  16. Functional Task Test: 1. Sensorimotor changes Associated with Postflight Alterations in Astronaut Functional Task Performance

    Science.gov (United States)

    Bloomberg, J. J.; Arzeno, N. H.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Platts, S. H.; Peters, B. T.; hide

    2011-01-01

    Space flight is known to cause alterations in multiple physiological systems including changes in sensorimotor, cardiovascular, and neuromuscular systems. These changes may affect a crewmember s ability to perform critical mission tasks immediately after landing on a planetary surface. The overall goal of this project is to determine the effects of space flight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. This presentation will focus on the sensorimotor contributions to postflight functional performance.

  17. A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

    Science.gov (United States)

    Augustsson, Jesper

    2016-08-01

    Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes

  18. Pain on Functional Movement Screen Tests and Injury Risk.

    Science.gov (United States)

    Bushman, Timothy T; Grier, Tyson L; Canham-Chervak, Michelle C; Anderson, Morgan K; North, William J; Jones, Bruce H

    2015-11-01

    The Functional Movement Screen (FMS) is a tool intended to evaluate limitations or asymmetries of movement to detect individuals at risk for exercise- and sports-related injury. The purpose was to determine the association and predictive value of specific FMS tests with injury risk in physically active men. Soldiers aged 18-57 years completed the FMS (n = 2,476). Demographic and fitness data were collected by survey. Medical record data for any, overuse, and traumatic injury 6 months after the assessment were obtained. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated along with receiver operator characteristics to determine area under the curve (AUC). Risks, risk ratios, odds ratios (ORs), and 95% confidence intervals were calculated to assess injury risks. Multivariate logistic regression identified that pain on 5 of the 7 tests was associated with greater risk for any injury (OR = 1.50-3.51): deep squat, hurdle step, in-line lunge, trunk stability push-up, and rotary stability. However, FMS registered low sensitivity, PPV, and AUC for all 7 tests for the 3 injury types (2-24% sensitivity, 16-74% PPV, and 50-58% AUC). Although the presence of pain was associated with a higher risk of injury on 5 tests, a low sensitivity, PPV, and AUC were displayed. Therefore, caution is advised when implementing the FMS as a screening tool in an Army or similarly active population as it could lead to prevention and treatment resources being directed toward individuals who are not at greater risk for injury.

  19. Tuboimpedance: A New Test of Eustachian Tube Function.

    Science.gov (United States)

    Smith, Matthew E; Zou, Charlie C; Blythe, Andrew J C; Tysome, James R

    2017-04-01

    Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.

  20. Functionally graded bioactive coatings: From fabrication to testing

    Science.gov (United States)

    Foppiano, Silvia

    Every year about half a million Americans undergo total joint replacement surgery of some kind. This number is expected to steadily increase in the future. About 20% of these patients will need a revision surgery because of implant failure, with a significant increase in health care cost. Current implant materials for load bearing applications must be strong enough to support the loads involved in daily activities, and bioinert, to limit reactivity in the body that may cause inflammatory and other adverse reactions. Metal alloys are typically used as materials for load bearing implants and rely on mechanical interlocking to achieve fixation which can be improved by using bone cements. To improve implant osteointegration, metal implants have been coated with a bone-like mineral: hydroxyapatite (HA). The plasma spray technique is commonly used to apply the HA coating. Such implants do not require the use of bone cement. Plasma sprayed HA coated implants are FDA approved and currently on the market, but their properties are not reproducible or reliable. Thus, coating delamination can occur. Our research group developed a novel family of bioactive glasses which were enameled onto titanium alloy using a functionally graded approach. We stratified the coating with different glass compositions to fulfill different functions. We coupled a first glass layer, with a good CTE match to the alloy, with a second layer of bioactive glass obtaining a functionally graded bioactive coating (FGC). In this thesis for the first time the cytocompatibility of novel bioactive glasses, and their functionally graded coatings on Ti6Al4V, was studied with an in vitro bone model (MC3T3-E1.4 mouse preosteblast cells). The novel bioactive glasses are cytocompatible and no compositional change is required. The fabrication process is reproducible, introduces a small (average 6 vol%) amount of crystallization, which does not significantly affect bioactivity in SBF as tested. The coatings are

  1. Pulmonary function tests in obese people candidate to bariatric surgery

    Directory of Open Access Journals (Sweden)

    C. Guimarães

    2012-05-01

    Full Text Available Obesity is considered one of the most serious public health problems of the modern world. Because it alters the relationship between the lungs, chest wall and diaphragm, it is to be expected that it impacts on the respiratory function. In Portugal, there is not much data about the relationship between obesity and pulmonary function.The aim of this study was to characterize respiratory function in morbidly obese patients and to evaluate whether weight loss in patients submitted to bariatric surgery affects pulmonary function tests (PFT.We conducted a retrospective study with 36 morbidly obese patients submitted to bariatric surgery, with a mean age of 40.6 years, 64% female and with a mean body mass index (BMI of 49.7 kg/m2. All patients were clinical and functionally evaluated before surgery and after their weight had stabilized following surgery. They underwent a complete pulmonary function testing with spirometry, lung volumes, carbon monoxide diffusing capacity (DLCO, maximum respiratory pressures and arterial blood gases analysis. Prior to surgery almost all the patients had functional respiratory changes, 34 had a decrease in functional residual capacity (FRC 6 of whom a restrictive syndrome. Only 2 patients did not show any functional or arterial blood gas change. After bariatric surgery, BMI decreased to 34 kg/m2 and there was a significant improvement in almost all functional parameters with resolution of restrictive disorders. Nevertheless, in 13 patients the FRC remained decreased.After weight loss, the only correlation found was between reduction of BMI and increased FRC (r = −0.371; p = 0.028. This study suggests a relationship between obesity and pulmonary restriction and a positive impact of bariatric surgery in PFT. Resumo: A obesidade é considerada um problema de saúde pública da atualidade. Devido ao facto de alterar a relação entre pulmões, parede torácica e diafragma, a obesidade tem

  2. Radioselenium pancreozymin-secretin test as a clinical test for pancreatic exocrine function

    International Nuclear Information System (INIS)

    Shichiri, M.; Etani, N.; Yoshida, M.; Harano, Y.; Hoshi, M.; Shigeta, Y.; Abe, H.

    1975-01-01

    The appearance of radioselenium in the protein fraction of duodenal aspirates has been studied after an intravenous injection of 75 Se-selenomethionine. The continuous flow of pancreatic juice was stimulated by pancreozymin at 120 minutes and by secretin at 140 minutes. A good distinction between normal subjects and patients with pancreatic disease was obtained by measuring 75 Se-radioactivity in the protein fraction of duodenal aspirates; either cumulative radioactivity during the combined 80-minute post-pancreozymin-secretin period, or maximum 75 Se-specific activity during the postsecretin period was used as an index. The test presented here might be a useful and sufficiently reliable method for detecting abnormal pancreatic exocrine function. This test can be performed along with the conventional pancreozymin-secretin test, serum enzyme response to pancreozymin and secretin, and pancreatic scintiscanning

  3. Functional Testing Differences in Anterior Cruciate Ligament Reconstruction Patients Released Versus Not Released to Return to Sport.

    Science.gov (United States)

    Mayer, Stephanie W; Queen, Robin M; Taylor, Dean; Moorman, Claude T; Toth, Allison P; Garrett, William E; Butler, Robert J

    2015-07-01

    No standardized return-to-activity or sport guidelines currently exist after anterior cruciate ligament (ACL) reconstruction. Isokinetic testing and unilateral hop testing, which have construct validity, are often used to make the determination of when a patient is ready to return to sport. Neither of these measures has been reported to be predictive of subsequent injuries. To compare the performance on 2 functional tests of ACL reconstruction patients released to return to activity versus those who have not been released based on clinical impairment measures. Cohort study; Level of evidence, 3. A total of 98 patients were examined by the treating orthopaedic surgeon 6 months after ACL reconstruction for traditional impairment measures, including swelling, range of motion, strength, and graft stability. After this examination, all subjects completed the functional testing, consisting of the Functional Movement Screen (FMS) and the Lower Quarter Y Balance Test (YBT-LQ), by an experienced tester who was blinded to the results of the clinical examination. On the basis of the clinical examination, all patients were grouped as being ready to return to sport or not being ready. Performance on the functional tests, as measured by overall performance and side-to-side asymmetry, was compared between the 2 groups using independent-samples t tests (P < .05). No difference existed between the groups with regard to the descriptive characteristics, with the exception that the group not cleared was younger (21.0 ± 7.4 years) than the group that was cleared (25.6 ± 13.2 years). Performance on the YBT-LQ revealed that no differences existed between groups when examining reach symmetry for any of the reach directions. In addition, no differences were found between groups when looking at the average reach score normalized to limb length for either the surgical or nonsurgical leg. Patients in the cleared group exhibited a similar score on the FMS (12.7 ± 2.9) compared with the

  4. Cochlear function tests in estimation of speech dynamic range.

    Science.gov (United States)

    Han, Jung Ju; Park, So Young; Park, Shi Nae; Na, Mi Sun; Lee, Philip; Han, Jae Sang

    2016-10-01

    The loss of active cochlear mechanics causes elevated thresholds, loudness recruitment, and reduced frequency selectivity. The problems faced by hearing-impaired listeners are largely related with reduced dynamic range (DR). The aim of this study was to determine which index of the cochlear function tests correlates best with the DR to speech stimuli. Audiological data on 516 ears with pure tone average (PTA) of ≤55 dB and word recognition score of ≥70% were analyzed. PTA, speech recognition threshold (SRT), uncomfortable loudness (UCL), and distortion product otoacoustic emission (DPOAE) were explored as the indices of cochlear function. Audiometric configurations were classified. Correlation between each index and the DR was assessed and multiple regression analysis was done. PTA and SRT demonstrated strong negative correlations with the DR (r = -0.788 and -0.860, respectively), while DPOAE sum was moderately correlated (r = 0.587). UCLs remained quite constant for the total range of the DR. The regression equation was Y (DR) = 75.238 - 0.719 × SRT (R(2 )=( )0.721, p equation.

  5. Occupational health surveillance: Pulmonary function testing in emergency responders

    Directory of Open Access Journals (Sweden)

    James D McCluskey

    2014-01-01

    Full Text Available Emergency responders may be exposed to a variety of fumes, gases, and particulates during the course of their job that can affect pulmonary function (PF and require the use of respiratory protection. This investigation used occupational health monitoring examination data to characterize PF in a population currently employed as emergency responders. PF tests for workers who required health examinations to ensure fitness for continued respirator use were compared to the National Health and Nutrition Examination Survey (NHANES III Raw Spirometry database to determine if decreased PF was associated with employment as an emergency responder. The results of this research indicated that the emergency responders experienced a modest, but statistically significant, increase in forced expiratory volume in 1 second (FEV1 and forced vital capacity (FVC mean values over the NHANES III population in both total and stratified analyses, including stratification by age, gender, height, and smoking history. Results are likely due to a combination of effectively controlled exposures in the workplace, and the healthy worker effect among long-term workers. PF testing required by the Occupational and Safety Health Administration (OSHA has substantial utility for conducting occupational surveillance at the population level. In this investigation, we were able to quickly evaluate if abnormal PF existed in an industrial sector known to have exposures that, when uncontrolled, can lead to PF impairment.

  6. Multiloop Integral System Test (MIST): MIST Facility Functional Specification

    International Nuclear Information System (INIS)

    Habib, T.F.; Koksal, C.G.; Moskal, T.E.; Rush, G.C.; Gloudemans, J.R.

    1991-04-01

    The Multiloop Integral System Test (MIST) is part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox designed plants. MIST is sponsored by the US Nuclear Regulatory Commission, the Babcock ampersand Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral facilities to address the thermal-hydraulic SBLOCA questions. MIST was specifically designed and constructed for this program, and an existing facility -- the Once Through Integral System (OTIS) -- was also used. Data from MIST and OTIS are used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The MIST Functional Specification documents as-built design features, dimensions, instrumentation, and test approach. It also presents the scaling basis for the facility and serves to define the scope of work for the facility design and construction. 13 refs., 112 figs., 38 tabs

  7. Above-Level Test Item Functioning across Examinee Age Groups

    Science.gov (United States)

    Warne, Russell T.; Doty, Kristine J.; Malbica, Anne Marie; Angeles, Victor R.; Innes, Scott; Hall, Jared; Masterson-Nixon, Kelli

    2016-01-01

    "Above-level testing" (also called "above-grade testing," "out-of-level testing," and "off-level testing") is the practice of administering to a child a test that is designed for an examinee population that is older or in a more advanced grade. Above-level testing is frequently used to help educators design…

  8. Bradykinesia-akinesia incoordination test: validating an online keyboard test of upper limb function.

    Science.gov (United States)

    Noyce, Alastair J; Nagy, Anna; Acharya, Shami; Hadavi, Shahrzad; Bestwick, Jonathan P; Fearnley, Julian; Lees, Andrew J; Giovannoni, Gavin

    2014-01-01

    The Bradykinesia Akinesia Incoordination (BRAIN) test is a computer keyboard-tapping task that was developed for use in assessing the effect of symptomatic treatment on motor function in Parkinson's disease (PD). An online version has now been designed for use in a wider clinical context and the research setting. Validation of the online BRAIN test was undertaken in 58 patients with Parkinson's disease (PD) and 93 age-matched, non-neurological controls. Kinesia scores (KS30, number of key taps in 30 seconds), akinesia times (AT30, mean dwell time on each key in milliseconds), incoordination scores (IS30, variance of travelling time between key presses) and dysmetria scores (DS30, accuracy of key presses) were compared between groups. These parameters were correlated against total motor scores and sub-scores from the Unified Parkinson's Disease Rating Scale (UPDRS). Mean KS30, AT30 and IS30 were significantly different between PD patients and controls (p≤0.0001). Sensitivity for 85% specificity was 50% for KS30, 40% for AT30 and 29% for IS30. KS30, AT30 and IS30 correlated significantly with UPDRS total motor scores (r = -0.53, r = 0.27 and r = 0.28 respectively) and motor UPDRS sub-scores. The reliability of KS30, AT30 and DS30 was good on repeated testing. The BRAIN test is a reliable, convenient test of upper limb motor function that can be used routinely in the outpatient clinic, at home and in clinical trials. In addition, it can be used as an objective longitudinal measurement of emerging motor dysfunction for the prediction of PD in at-risk cohorts.

  9. Bradykinesia-akinesia incoordination test: validating an online keyboard test of upper limb function.

    Directory of Open Access Journals (Sweden)

    Alastair J Noyce

    Full Text Available The Bradykinesia Akinesia Incoordination (BRAIN test is a computer keyboard-tapping task that was developed for use in assessing the effect of symptomatic treatment on motor function in Parkinson's disease (PD. An online version has now been designed for use in a wider clinical context and the research setting.Validation of the online BRAIN test was undertaken in 58 patients with Parkinson's disease (PD and 93 age-matched, non-neurological controls. Kinesia scores (KS30, number of key taps in 30 seconds, akinesia times (AT30, mean dwell time on each key in milliseconds, incoordination scores (IS30, variance of travelling time between key presses and dysmetria scores (DS30, accuracy of key presses were compared between groups. These parameters were correlated against total motor scores and sub-scores from the Unified Parkinson's Disease Rating Scale (UPDRS.Mean KS30, AT30 and IS30 were significantly different between PD patients and controls (p≤0.0001. Sensitivity for 85% specificity was 50% for KS30, 40% for AT30 and 29% for IS30. KS30, AT30 and IS30 correlated significantly with UPDRS total motor scores (r = -0.53, r = 0.27 and r = 0.28 respectively and motor UPDRS sub-scores. The reliability of KS30, AT30 and DS30 was good on repeated testing.The BRAIN test is a reliable, convenient test of upper limb motor function that can be used routinely in the outpatient clinic, at home and in clinical trials. In addition, it can be used as an objective longitudinal measurement of emerging motor dysfunction for the prediction of PD in at-risk cohorts.

  10. The database for reaching experiments and models.

    Directory of Open Access Journals (Sweden)

    Ben Walker

    Full Text Available Reaching is one of the central experimental paradigms in the field of motor control, and many computational models of reaching have been published. While most of these models try to explain subject data (such as movement kinematics, reaching performance, forces, etc. from only a single experiment, distinct experiments often share experimental conditions and record similar kinematics. This suggests that reaching models could be applied to (and falsified by multiple experiments. However, using multiple datasets is difficult because experimental data formats vary widely. Standardizing data formats promises to enable scientists to test model predictions against many experiments and to compare experimental results across labs. Here we report on the development of a new resource available to scientists: a database of reaching called the Database for Reaching Experiments And Models (DREAM. DREAM collects both experimental datasets and models and facilitates their comparison by standardizing formats. The DREAM project promises to be useful for experimentalists who want to understand how their data relates to models, for modelers who want to test their theories, and for educators who want to help students better understand reaching experiments, models, and data analysis.

  11. Correlation Between Haematological Parameters, Kidney Function Tests and Liver Function Tests in Plasmodium Falciparum and Vivax Malaria

    Directory of Open Access Journals (Sweden)

    Mitul Chhatriwala

    2017-12-01

    Full Text Available Abstract: Malaria remains a major cause of morbidity and mortality in India. Plasmodium falciparum remains the main culprit although cases with vivax malaria are on the rise. Severe malaria as defined by the WHO criteria has high rate of complications and mortality. In our study we recruited microscopy positive falciparum and vivax malaria patients. Haematological and biochemical laboratory investigations were carried out in recruited patients. Both parameters were found to be significantly derailed in falciparum cases as compared to vivax. A direct correlation has been observed between kidney function tests (serum creatinine,serum urea and direct bilirubin levels across all cases of malaria. Hence these parameters can be used to identify and monitor the progress of cases of severe malaria as significant proportion of patients fulfilled the criteria of severe malaria in the cohort.

  12. Forward lunge as a functional performance test in ACL deficient subjects: test-retest reliability

    DEFF Research Database (Denmark)

    Alkjaer, Tine; Henriksen, Marius; Dyhre-Poulsen, Poul

    2009-01-01

    The forward lunge movement may be used as a functional performance test of anterior cruciate ligament (ACL) deficient and reconstructed subjects. The purposes were 1) to determine the test-retest reliability of a forward lunge in healthy subjects and 2) to determine the required numbers...... of repetitions necessary to yield satisfactory reliability. Nineteen healthy subjects performed four trials of a forward lunge on two different days. The movement time, impulses of the ground reaction forces (IFz, IFy), knee joint kinematics and dynamics during the forward lunge were calculated. The relative...... reliability was determined by calculation of Intraclass Correlation Coefficients (ICC). The IFz, IFy and the positive work of the knee extensors showed excellent reliability (ICC >0.75). All other variables demonstrated acceptable reliability (0.4>ICCreliability increased when more than...

  13. Safety system function trend indicator: Theory and test application

    International Nuclear Information System (INIS)

    Azarm, M.A.; Carbonaro, J.F.; Boccio, J.L.; Vesely, W.E.

    1989-01-01

    The purpose of this paper is to summarize research conducted on the development and validation of quantitative indicators of safety performance. This work, performed under the Risk-Based Performance Indicator (RBPI) Project, FIN A-3295, for the Office of Research (RES), is considered part of NRC's Performance Indicator Program which is being coordinated through the Office for the Analysis and Evaluation of Operational Data (AEOD). The program originally focused on risk-based indicators at high levels of safety indices (e.g., core-damage frequency, functional unavailabilities, and sequence monitoring). The program was then redirected towards a more amenable goal, safety system unavailability indicators, mainly due to the lack of PRA models and plant data. In that regard, BNL published a technical report that introduced the concept of cycle-based indicators and also described various alternatives of monitoring safety system unavailabilities. Further simplification of these indicators was requested by NRC to facilitate their applications to all plants in a timely manner. This resulted in the development of Safety System Function Trend (SSFT) indicators which minimize the need for detailed system model as well as component history. The theoretical bases for these indicators were developed through various simulation studies to determine the ease of detecting a trend and/or unacceptable performance. These indicators, along with several other indicators, were then generated and compared using plant data as a part of a test application. The SSFT indicators, specifically, were constructed for a total of eight plants, consisting of two systems per plant. Emphasis was placed on examining relative changes, as well as the indicator's actual level. Both the trend and actual indicator level were found to be important in identifying plants with potential problems

  14. Characterization of thyroid function and antithyroid antibody tests among Saudis

    Science.gov (United States)

    Jammah, Anwar A.; Alshehri, Anwar S.; Alrakhis, Afaf A.; Alhedaithy, Asma S.; Almadhi, Asma M.; Alkwai, Hala M.; Alhamad, Maram M.; Alzahrani, Saad H.

    2015-01-01

    Objective: To determine the reference intervals for thyroid function tests and the prevalence of thyroid autoimmunity in the Saudi population. Methods: A cross-sectional prospective study was conducted in King Khalid University Hospital, Riyadh, Saudi Arabia from January to June 2013. History and physical examination were obtained. Thyroid-stimulating hormone (TSH), free thyroxine (FT4), and free triiodothyronine (FT3) were measured by Electro-chemiluminescence Immunoassay system-assay. Anti-thyroperoxidase, and anti-thyroglobulin antibodies were measured using enzyme-linked immunosorbent-assay. Subjects with previous or a family history of thyroid disorders, those taking medications affecting thyroid function, pregnant or lactating women, and those with goiter were excluded. Individuals with positive antibodies were excluded from the final analysis of the TSH reference range, but were used to determine the prevalence of thyroid autoimmunity. Results: Out of 337 Saudi subjects initially screened, 132 (aged 13-60 years) were candidates for reference calculation, the mean±standard deviation, and (2.5th-97.5th) percentile of TSH (mIU/L) was 1.96±0.9 (0.59-4.37), for FT4 (pmol/L) was 15.47±1.83 (12.04-19.13), and for FT3 (pmol/L) was 5.22±0.7 (4.07-6.76). The TSH was higher in the antibodies positive group (2.5±1.17 mIU/L) compared with the negative one (1.96±0.9 mIU/L) (pantithyroid antibodies. Conclusion: The TSH reference range was similar to laboratory references. Thyroid antibodies were prevalent in Saudis, necessitating further work in larger scale studies. PMID:25987111

  15. Assessment of platelet function in healthy sedated cats using three whole blood platelet function tests.

    Science.gov (United States)

    Ho, Kimberly K; Abrams-Ogg, Anthony C G; Wood, R Darren; O'Sullivan, M Lynne; Kirby, Gordon M; Blois, Shauna L

    2015-05-01

    The objectives of this study were to establish feline references intervals for 3 commercial whole blood platelet function test analyzer systems: Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), Platelet Function Analyzer-100 (PF: Siemens Canada, Mississauga, Ontario, Canada), and Plateletworks Combo-25 kit (PW; Helena Laboratories, Beaumont, TX). Venipuncture was performed on 55 healthy sedated cats, and platelet aggregation in response to adenosine diphosphate (ADP), collagen (COL), and arachidonic acid (AA; MP only) was assessed using citrated blood. For the MP analyzer, median (95% confidence intervals [CIs]) area under curve (Units) for ADP, COL, and AA agonists were 87 (11-176), 81 (32-129), and 91 (59-129), respectively. For the PF analyzer, median (95% CIs) closure time, using COL-ADP cartridges, was 69 (46-89) sec. For the PW assay, median (95% CIs) percent aggregations for ADP and COL agonists were 71 (18-92) and 49 (9-96), respectively, using impedance hematology analyzer platelet counts, and 94 (25-98) and 68 (14-119), respectively, using flow cytometry hematology analyzer platelet counts. There were low correlations between the PF analyzer (COL-ADP cartridge) and MP analyzer (COL agonist; ρ = 0.11), and between the PF analyzer (COL-ADP cartridge) and PW assay (COL agonist using impedance platelet counts; ρ = 0.14). The PW assay percent aggregations using impedance and flow cytometric platelet counts were correlated for both ADP (ρ = 0.64) and COL (ρ = 0.64) agonists. Platelet function testing using these tests are feasible in cats, but 95% CIs are wide, so single results may be difficult to interpret. Platelet counting by impedance or flow cytometry may be used for the PW assay but are not interchangeable. © 2015 The Author(s).

  16. Potential Functional Embedding Theory at the Correlated Wave Function Level. 2. Error Sources and Performance Tests.

    Science.gov (United States)

    Cheng, Jin; Yu, Kuang; Libisch, Florian; Dieterich, Johannes M; Carter, Emily A

    2017-03-14

    Quantum mechanical embedding theories partition a complex system into multiple spatial regions that can use different electronic structure methods within each, to optimize trade-offs between accuracy and cost. The present work incorporates accurate but expensive correlated wave function (CW) methods for a subsystem containing the phenomenon or feature of greatest interest, while self-consistently capturing quantum effects of the surroundings using fast but less accurate density functional theory (DFT) approximations. We recently proposed two embedding methods [for a review, see: Acc. Chem. Res. 2014 , 47 , 2768 ]: density functional embedding theory (DFET) and potential functional embedding theory (PFET). DFET provides a fast but non-self-consistent density-based embedding scheme, whereas PFET offers a more rigorous theoretical framework to perform fully self-consistent, variational CW/DFT calculations [as defined in part 1, CW/DFT means subsystem 1(2) is treated with CW(DFT) methods]. When originally presented, PFET was only tested at the DFT/DFT level of theory as a proof of principle within a planewave (PW) basis. Part 1 of this two-part series demonstrated that PFET can be made to work well with mixed Gaussian type orbital (GTO)/PW bases, as long as optimized GTO bases and consistent electron-ion potentials are employed throughout. Here in part 2 we conduct the first PFET calculations at the CW/DFT level and compare them to DFET and full CW benchmarks. We test the performance of PFET at the CW/DFT level for a variety of types of interactions (hydrogen bonding, metallic, and ionic). By introducing an intermediate CW/DFT embedding scheme denoted DFET/PFET, we show how PFET remedies different types of errors in DFET, serving as a more robust type of embedding theory.

  17. Newton force from wave function collapse: speculation and test

    International Nuclear Information System (INIS)

    Diósi, Lajos

    2014-01-01

    The Diosi-Penrose model of quantum-classical boundary postulates gravity-related spontaneous wave function collapse of massive degrees of freedom. The decoherence effects of the collapses are in principle detectable if not masked by the overwhelming environmental decoherence. But the DP (or any other, like GRW, CSL) spontaneous collapses are not detectable themselves, they are merely the redundant formalism of spontaneous decoherence. To let DP collapses become testable physics, recently we extended the DP model and proposed that DP collapses are responsible for the emergence of the Newton gravitational force between massive objects. We identified the collapse rate, possibly of the order of 1/ms, with the rate of emergence of the Newton force. A simple heuristic emergence (delay) time was added to the Newton law of gravity. This non-relativistic delay is in peaceful coexistence with Einstein's relativistic theory of gravitation, at least no experimental evidence has so far surfaced against it. We derive new predictions of such a 'lazy' Newton law that will enable decisive laboratory tests with available technologies. The simple equation of 'lazy' Newton law deserves theoretical and experimental studies in itself, independently of the underlying quantum foundational considerations.

  18. Pulmonary Function Tests In Young Healthy Subjects Of North India

    Directory of Open Access Journals (Sweden)

    Parag Rastogi

    2004-06-01

    Full Text Available Study Objectives : The diagnosis of disease done by skiagram can be substantiated by pulmonary function tests. Substantial data of Indians on PFTs is not available. The present study therefore has been planned on young healthy north Indians.Setting : 119 males and 49 female medical students of North India.Measurements : PFT's, T.V. FEV1, FVC, FER and PEFR were measured. P<0.05 was considered as significant.Results : In North Indian males, mean T. V was 437.56 ± 65.83 ml, FEV1 3.26 ±041 L, FVC 3.82 ± 0.48 L, FER 85.09 ± 2.42% and PEFR was 495.42 ± 101.82 L / min. In North Indian females, average T. V was 386.12 ± 37.90 ml, FEV1 2.39 ± 0.38 L, FVC 2.79 ± 0.43 L, FER 85.38 ± 257% and PEFR was 307.12 ± 75.74 L / min.Conclusions: Males in comparison to females had more value of PFTs. All the PFTs showed positive correlation with Height, Weight and Surface area except Tidal Volume and FER.

  19. Assessment of Dengue Fever Severity Through Liver Function Tests

    International Nuclear Information System (INIS)

    Ahmed, A.; Alvi, A. H.; Nawaz, A. A.; Butt, A.; Hanif, A.

    2014-01-01

    Objective: To assess the utility of liver function tests (LFTs) for early recognition and prediction of severity of Dengue fever in hospitalized patients. Study Design: An analytical study. Place and Duration of Study: Services Institute of Medical Science and Fatima Memorial Hospital, Lahore, from September - December 2010. Methodology: Admitted cases of Dengue fever were divided into 3 groups; mild, moderate and severe increases in aminotransferases. Elevation in LFTs was co-related with good or bad outcome i.e. (survival or complication free stay) or (death or complications). Results were analyzed in SPSS version 18. Results: Out of the 353 patients with mean age of 37.12 +- 15.45 years, 245 (69.4%) were males and 108 (30.6%) were females. Seventy five patients (21.2%) had mild elevation of aminotransferases (2 fold increases), 265 patients (75.1%) had moderate increases (3 to 4 fold) and 13 (3.7%) had severe (> 4 fold increase). ALT was statistically higher in patients with septicemia, hepatic and renal failure (p-value 0.05). AST was higher in almost all complications. Prolonged hospital stay was associated with raised LFTs and greater complications and mortality. AST was found to be twice as much raised as ALT. Conclusion: AST and ALT were statistically higher in patients with worse outcome thus can lead to early recognition of high risk cases. (author)

  20. Design and functional tests of the Euclid grism mount

    Science.gov (United States)

    Rossin, Ch.; Grange, R.; Caillat, A.; Costille, A.; Sanchez, P.; Ceria, W.

    2017-11-01

    The Euclid mission selected by ESA in the Cosmic Vision program is dedicated to understand dark energy and dark matter. One of the probes based on detection of Baryonic Acoustic Oscillations required the redshift of millions of galaxies. This massive spectroscopic survey relies on the Near Infrared SpectroPhotometer (NISP) using grism in slitless mode. In this Euclid NISP context, we designed a cryogenic mount for the four grisms of the spectroscopic channel. This mount has to maintain optical performances and alignment at the cryogenic temperature of 120K and to survive launch vibrations. Due to a very small mass and volume budget allowed in the Grism Wheel Assembly our design relies on a weight relief Invar ring glued to the grism by tangential flexures. Tangential flexures have the advantage of small height but the drawback of less decoupling capabilities than bipods. We will present the design of the mount and the integration and functional tests to stay within the 60 nm RMS transmitted wavefront error budget allowed to the grism.

  1. Guaranteed performance in reaching mode of sliding mode ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    addresses the design of constant plus proportional rate reaching law-based SMC for second-order ... Reaching mode; sliding mode controlled systems; output tracking ... The uncertainty in the input distribution function g is expressed as.

  2. Pulmonary Function Testing After Stereotactic Body Radiotherapy to the Lung

    Energy Technology Data Exchange (ETDEWEB)

    Bishawi, Muath [Division of Cardiothoracic Surgery, Stony Brook University Medical Center, Stony Brook, NY (United States); Kim, Bong [Division of Radiology, Stony Brook University Medical Center, Stony Brook, NY (United States); Moore, William H. [Division of Radiation Oncology, Stony Brook University, Stony Brook, NY (United States); Bilfinger, Thomas V., E-mail: Thomas.bilfinger@stonybrook.edu [Division of Cardiothoracic Surgery, Stony Brook University Medical Center, Stony Brook, NY (United States)

    2012-01-01

    Purpose: Surgical resection remains the standard of care for operable early-stage non-small-cell lung cancer (NSCLC). However, some patients are not fit for surgery because of comorbidites such as chronic obstructive pulmonary disease (COPD) and other medical conditions. We aimed to evaluate pulmonary function and tumor volume before and after stereotactic body radiotherapy (SBRT) for patients with and without COPD in early-stage lung cancer. Methods and Materials: A review of prospectively collected data of Stage I and II lung cancers, all treated with SBRT, was performed. The total SBRT treatment was 60 Gy administered in three 20 Gy fractions. The patients were analyzed based on their COPD status, using their pretreatment pulmonary function test cutoffs as established by the American Thoracic Society guidelines (forced expiratory volume [FEV]% {<=}50% predicted, FEV%/forced vital capacity [FVC]% {<=}70%). Changes in tumor volume were also assessed by computed tomography. Results: Of a total of 30 patients with Stage I and II lung cancer, there were 7 patients in the COPD group (4 men, 3 women), and 23 in t he No-COPD group (9 men, 14 women). At a mean follow-up time of 4 months, for the COPD and No-COPD patients, pretreatment and posttreatment FEV% was similar: 39 {+-} 5 vs. 40 {+-} 9 (p = 0.4) and 77 {+-} 0.5 vs. 73 {+-} 24 (p = 0.9), respectively. The diffusing capacity of the lungs for carbon monoxide (DL{sub CO}) did significantly increase for the No-COPD group after SBRT treatment: 60 {+-} 24 vs. 69 {+-} 22 (p = 0.022); however, DL{sub CO} was unchanged for the COPD group: 49 {+-} 13 vs. 50 {+-} 14 (p = 0.8). Although pretreatment tumor volume was comparable for both groups, tumor volume significantly shrank in the No-COPD group from 19 {+-} 24 to 9 {+-} 16 (p < 0.001), and there was a trend in the COPD patients from 12 {+-} 9 to 6 {+-} 5 (p = 0.06). Conclusion: SBRT did not seem to have an effect on FEV{sub 1} and FVC, but it shrank tumor volume and

  3. Pulmonary Function Testing After Stereotactic Body Radiotherapy to the Lung

    International Nuclear Information System (INIS)

    Bishawi, Muath; Kim, Bong; Moore, William H.; Bilfinger, Thomas V.

    2012-01-01

    Purpose: Surgical resection remains the standard of care for operable early-stage non–small-cell lung cancer (NSCLC). However, some patients are not fit for surgery because of comorbidites such as chronic obstructive pulmonary disease (COPD) and other medical conditions. We aimed to evaluate pulmonary function and tumor volume before and after stereotactic body radiotherapy (SBRT) for patients with and without COPD in early-stage lung cancer. Methods and Materials: A review of prospectively collected data of Stage I and II lung cancers, all treated with SBRT, was performed. The total SBRT treatment was 60 Gy administered in three 20 Gy fractions. The patients were analyzed based on their COPD status, using their pretreatment pulmonary function test cutoffs as established by the American Thoracic Society guidelines (forced expiratory volume [FEV]% ≤50% predicted, FEV%/forced vital capacity [FVC]% ≤70%). Changes in tumor volume were also assessed by computed tomography. Results: Of a total of 30 patients with Stage I and II lung cancer, there were 7 patients in the COPD group (4 men, 3 women), and 23 in t he No-COPD group (9 men, 14 women). At a mean follow-up time of 4 months, for the COPD and No-COPD patients, pretreatment and posttreatment FEV% was similar: 39 ± 5 vs. 40 ± 9 (p = 0.4) and 77 ± 0.5 vs. 73 ± 24 (p = 0.9), respectively. The diffusing capacity of the lungs for carbon monoxide (DL CO ) did significantly increase for the No-COPD group after SBRT treatment: 60 ± 24 vs. 69 ± 22 (p = 0.022); however, DL CO was unchanged for the COPD group: 49 ± 13 vs. 50 ± 14 (p = 0.8). Although pretreatment tumor volume was comparable for both groups, tumor volume significantly shrank in the No-COPD group from 19 ± 24 to 9 ± 16 (p 1 and FVC, but it shrank tumor volume and improved DL CO for patients without COPD.

  4. PWR primary system chemistry control during hot functional testing

    International Nuclear Information System (INIS)

    Reid, Richard D.; Little, Michael J.

    2014-01-01

    Hot Functional Testing (HFT) involves a number of pre-operational exercises performed to confirm the operability of plant systems at conditions expected during both normal and off-normal operation of a pressurized water reactor (PWR), including operability of safety systems. While the primary purposes of HFT are to demonstrate operability of plant systems and satisfy regulatory requirements, chemistry control during HFT is important to long-term integrity and performance of plant systems. Specifically, HFT is the first time plant equipment is exposed to high temperature water and the chemistry maintained during HFT can impact the passivation layers that form on wetted surfaces and long-term release of metals from these surfaces. Metals released from the inner surfaces of steam generator tubing and reactor coolant loop piping become activated in the core and can redeposit on ex-core surfaces. Because HFT is performed before fuel is loaded in the core, HFT provides an opportunity to produce a passive layer on primary surfaces that is free of activated corrosion products, resistant to metals release during subsequent plant operation, and also resistant to incorporation of activated corrosion products (once fuel is loaded in the core). Thus, maintaining desirable primary chemistry control during HFT is important for source term management, minimization of future shutdown activity releases, minimization of dose rates, and asset preservation. This paper presents an overview of passive film formation in the austenitic stainless steel and high nickel alloys that make up the majority of the primary circuit in advanced PWR designs. Based on this information, a summary is provided of the effects on passive film formation of key chemistry parameters that may be controlled during HFT. (author)

  5. Hip abduction-adduction strength and one-leg hop tests: test-retest reliability and relationship to function in elite ice hockey players.

    Science.gov (United States)

    Kea, J; Kramer, J; Forwell, L; Birmingham, T

    2001-08-01

    Single group, test-retest. To determine: (1) hip abduction and adduction torques during concentric and eccentric muscle actions, (2) medial and lateral one-leg hop distances, (3) the test-retest reliability of these measurements, and (4) the relationship between isokinetic measures of hip muscle strength and hop distances in elite ice hockey players. The skating motion used in ice hockey requires strong contractions of the hip and knee musculature. However, baseline scores for hip strength and hop distances, their test-retest reliability, and measures of the extent to which these tests are related for this population are not available. The dominant leg of 27 men (mean age 20 +/- 3 yrs) was tested on 2 occasions. Hip abduction and adduction movements were completed at 60 degrees.s(-1) angular velocity, with the subject lying on the non-test side and the test leg moving vertically in the subject's coronal plane. One-leg hops requiring jumping from and landing on the same leg without losing balance were completed in the medial and lateral directions. Hip adduction torques were significantly greater than abduction torques during both concentric and eccentric muscle actions, while no significant difference was observed between medial and lateral hop distances. Although hop test scores produced excellent ICCs (> 0.75) when determined using scores on 1 occasion, torques needed to be averaged over 2 test occasions to reach this level. Correlations between the strength and hop tests ranged from slight to low (r = -0.26 to 0.27) and were characterized by wide 95% confidence intervals (-0.54 to 0.61). Isokinetic tests of hip abduction and adduction did not provide a strong indication of performance during sideways hop tests. Although isokinetic tests can provide a measure of muscular strength under specific test conditions, they should not be relied upon as a primary indicator of functional abilities or readiness to return to activity.

  6. Highly adaptive tests for group differences in brain functional connectivity

    Directory of Open Access Journals (Sweden)

    Junghi Kim

    2015-01-01

    The proposed tests combine statistical evidence against a null hypothesis from multiple sources across a range of plausible tuning parameter values reflecting uncertainty with the unknown truth. These highly adaptive tests are not only easy to use, but also high-powered robustly across various scenarios. The usage and advantages of these novel tests are demonstrated on an Alzheimer's disease dataset and simulated data.

  7. Age-related cognitive decline as a function of daytime testing.

    Science.gov (United States)

    Puiu, Andrei Alexandru

    2017-05-01

    The current study investigates the effects of age, cognitive load, optimal time-of-day testing, and irrelevant background noise suppression on mental processing. One hundred and seventy-eight young (M = 22.97 years) and 114 old adults (M = 56.38 years) were assessed for implicit learning and speed of information processing under irrelevant sound interference early during daytime (7AM-2.30PM) or in the afternoons (3PM-midnight). No direct effect of irrelevant speech effect was found on implicit learning. An optimal time of testing per age group was identified according to the ability to suppress irrelevant auditory information. If no semantic meaning was derived from the sound conditions, irrelevant sound was easily inhibited leaving no room for declined cognitive performance. This suggests an intact phonological inhibition in older adults and a further circumvention of the phonological loop. However, when difficulty was increased, a widened performance gap between young and old people could be observed. Education modulated difficult performance irrespective of age. With increasing age, task demand fulfillment becomes a function of a limited time mechanism. If extraneous time is not adapted to cognitive skills and performance, higher order processing cannot be reached, rendering older adults slower than their younger counterparts.

  8. The Unilateral Below Elbow Test: a function test for children with unilateral congenital below elbow deficiency.

    Science.gov (United States)

    Bagley, Anita M; Molitor, Fred; Wagner, Lisa V; Tomhave, Wendy; James, Michelle A

    2006-07-01

    The Unilateral Below Elbow Test (UBET) was developed to evaluate function in bimanual activities for both the prosthesis wearer and non-wearer. Nine tasks were chosen for each of four age-specific categories defined by development stages of hand function (2-4y, 5-7y, 8-10y, and 11-21y). Two scales, Completion of Task and Method of Use, were designed to rate performance. To measure reliability, four occupational therapists scored samples of videotaped UBET performances. For Completion of Task, an interval scale, agreement in scoring was measured with interclass correlation coefficients (ICC; n=9; five females, four males). For Method of Use, a nominal scale, chance-adjusted association was calculated with Cohen's kappa coefficients (interobserver n=198; 111 females, 87 males; intraobserver n=93; 56 females, 37 males). For Completion of Task, the average ICC was 0.87 for the prosthesis-on condition, and 0.85 for the prosthesis-off condition. ICCs exceeded 0.80 for eight out of nine tasks for the two older age groups, but for only five out of nine tasks in the younger age groups. Higher inter- and intraobserver kappa coefficients for Method of Use resulted when scoring children with their prostheses on versus off. The oldest age group had lower kappa values than the other three groups. The UBET is recommended for the functional evaluation of Completion of Task in children with unilateral congenital below elbow deficiency with and without their prostheses. Method of Use scoring can evaluate individuals for directed therapy interventions or prosthetic training.

  9. Level of flexibility through sit and reach test from research performed in São Paulo city doi: 10.5007/1980-0037.2010v12n6p415

    Directory of Open Access Journals (Sweden)

    Cibele Calvi Anic Ribeiro

    2010-09-01

    Full Text Available The objective of this study was to examine the level of flexibility in men and women of different ages by the sit-and-reach test and to classify them according to the Canadian Standardized Test of Fitness (CSTF. The results were used to elaborate a new table that reflects the population studied. The sample consisted of 16,405 physically active and inactive subjects who were divided according to age: 15 to 19 (n = 954, 20 to 29 (n = 2916, 30 to 39 (n = 2161, 40 to 49 (n = 2333, 50 to 59 (n = 2739, 60 to 69 (n = 3195, and > 70 years (n = 2107. Percentiles were calculated using the original test scores and the 20th, 40th, 60th and 80th percentiles were used as cut-offs for classification as poor, below the average, average, above the average and excellent, respectively. According to the CSTF classification, the age groups from 15 to 39 years were classified as poor, with mean flexibility ranging from 24.805±9.684 to 26.130± 10.111 cm in women and from 21.480±9.905 to 22.848±9.648 cm in men. In the 40- to 69-year age groups, mean flexibility ranged from 22.768±9.627 to 25.396±9.547 in women and from 16.396±10.136 to 19.935±9.192 cm in men and was classified as below the average. Although most of the subjects performed regular exercise, the mean flexibility level observed did not correspond to the average suggested by the CSTF, demonstrating the importance of elaborating national reference tables and of establishing new normative values such as the table proposed in this study.

  10. Test Review: Barkley Deficits in Executive Functioning Scale (BDEFS)

    Science.gov (United States)

    Allee-Smith, Paula J.; Winters, Rebecca R.; Drake, Amanda; Joslin, Amanda K.

    2013-01-01

    The Barkley Deficits in Executive Functioning Scale (BDEFS), authored by Russell A. Barkley and published by Guilford in 2011, is an individually administered assessment tool that may be used to evaluate adults ages 18 to 81. The purpose of this measure is to screen those who may be experiencing executive functioning (EF) deficits in…

  11. 75 FR 50853 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Science.gov (United States)

    2010-08-18

    ... airplanes. 1. Function and Reliability Testing. Flight tests: In place of 14 CFR 21.35(b)(2), the following...; Function and Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final special... to CAR part 3 became effective January 15, 1951, and deleted the service test requirements in Section...

  12. Development of the EpiOcular(TM) eye irritation test for hazard identification and labelling of eye irritating chemicals in response to the requirements of the EU cosmetics directive and REACH legislation.

    Science.gov (United States)

    Kaluzhny, Yulia; Kandárová, Helena; Hayden, Patrick; Kubilus, Joseph; d'Argembeau-Thornton, Laurence; Klausner, Mitchell

    2011-09-01

    The recently implemented 7th Amendment to the EU Cosmetics Directive and the EU REACH legislation have heightened the need for in vitro ocular test methods. To address this need, the EpiOcular(TM) eye irritation test (EpiOcular-EIT), which utilises the normal (non-transformed) human cell-based EpiOcular tissue model, has been developed. The EpiOcular-EIT prediction model is based on an initial training set of 39 liquid and 21 solid test substances and uses a single exposure period and a single cut-off in tissue viability, as determined by the MTT assay. A chemical is classified as an irritant (GHS Category 1 or 2), if the tissue viability is ≤ 60%, and as a non-irritant (GHS unclassified), if the viability is > 60%. EpiOcular-EIT results for the training set, along with results for an additional 52 substances, which included a range of alcohols, hydrocarbons, amines, esters, and ketones, discriminated between ocular irritants and non-irritants with 98.1% sensitivity, 72.9% specificity, and 84.8% accuracy. To ensure the long-term commercial viability of the assay, EpiOcular tissues produced by using three alternative cell culture inserts were evaluated in the EpiOcular-EIT with 94 chemicals. The assay results obtained with the initial insert and the three alternative inserts were very similar, as judged by correlation coefficients (r²) that ranged from 0.82 to 0.96. The EpiOcular-EIT was pre-validated in 2007/2008, and is currently involved in a formal, multi-laboratory validation study sponsored by the European Cosmetics Association (COLIPA) under the auspices of the European Centre for the Validation of Alternative Methods (ECVAM). The EpiOcular-EIT, together with EpiOcular's long history of reproducibility and proven utility for ultra-mildness testing, make EpiOcular a useful model for addressing current legislation related to animal use in the testing of potential ocular irritants. 2011 FRAME.

  13. Comparison of Esophageal Function Tests in Chinese Patients with Functional Heartburn and Reflux Hypersensitivity

    Directory of Open Access Journals (Sweden)

    Feng Gao

    2017-01-01

    Full Text Available Objective. To investigate the differences in the results of esophageal function tests for functional heartburn (FH and reflux hypersensitivity (RH. Methods. Patients with FH and RH and healthy volunteers (HVs from the Department of Gastroenterology, Beijing Anzhen Hospital and Beijing Chao-Yang hospital, who underwent high-resolution manometry and impedance (HRIM, and 24-hour multichannel intraluminal impedance and pH recording (MII/pH between 2014 and 2016, were enrolled in this study. Results. 36 HV, 147 FH patients, and 91 RH patients were enrolled. The postreflux swallow-induced peristaltic wave index (PSPW index and mean nocturnal baseline impedance (MNBI values were significantly lower in RH than in FH and HV. The ineffective esophageal motility (IEM, fragmented peristalsis rates, total bolus exposure, proximal total reflux events, and distal total reflux events were significantly greater in RH than in FH and HV. Conclusions. Compared to HV and FH patients, RH patients exhibited greater IEM and fragmented peristalsis rates, a greater total bolus exposure, more proximal total and distal total reflux events, and reduced chemical clearance and mucosal integrity. By using the above described parameters, HRIM and MII/pH assays could be used to correctly classify RH and FH and hence allow physicians to provide adequate relief from associated symptoms.

  14. Reaching ignition in the tokamak

    International Nuclear Information System (INIS)

    Furth, H.P.

    1985-06-01

    This review covers the following areas: (1) the physics of burning plasmas, (2) plasma physics requirements for reaching ignition, (3) design studies for ignition devices, and (4) prospects for an ignition project

  15. The BACHD Rat Model of Huntington Disease Shows Specific Deficits in a Test Battery of Motor Function.

    Science.gov (United States)

    Manfré, Giuseppe; Clemensson, Erik K H; Kyriakou, Elisavet I; Clemensson, Laura E; van der Harst, Johanneke E; Homberg, Judith R; Nguyen, Huu Phuc

    2017-01-01

    Rationale : Huntington disease (HD) is a progressive neurodegenerative disorder characterized by motor, cognitive and neuropsychiatric symptoms. HD is usually diagnosed by the appearance of motor deficits, resulting in skilled hand use disruption, gait abnormality, muscle wasting and choreatic movements. The BACHD transgenic rat model for HD represents a well-established transgenic rodent model of HD, offering the prospect of an in-depth characterization of the motor phenotype. Objective : The present study aims to characterize different aspects of motor function in BACHD rats, combining classical paradigms with novel high-throughput behavioral phenotyping. Methods : Wild-type (WT) and transgenic animals were tested longitudinally from 2 to 12 months of age. To measure fine motor control, rats were challenged with the pasta handling test and the pellet reaching test. To evaluate gross motor function, animals were assessed by using the holding bar and the grip strength tests. Spontaneous locomotor activity and circadian rhythmicity were assessed in an automated home-cage environment, namely the PhenoTyper. We then integrated existing classical methodologies to test motor function with automated home-cage assessment of motor performance. Results : BACHD rats showed strong impairment in muscle endurance at 2 months of age. Altered circadian rhythmicity and locomotor activity were observed in transgenic animals. On the other hand, reaching behavior, forepaw dexterity and muscle strength were unaffected. Conclusions : The BACHD rat model exhibits certain features of HD patients, like muscle weakness and changes in circadian behavior. We have observed modest but clear-cut deficits in distinct motor phenotypes, thus confirming the validity of this transgenic rat model for treatment and drug discovery purposes.

  16. Design of New Test Function Model Based on Multi-objective Optimization Method

    Directory of Open Access Journals (Sweden)

    Zhaoxia Shang

    2017-01-01

    Full Text Available Space partitioning method, as a new algorism, has been applied to planning and decision-making of investment portfolio more and more often. But currently there are so few testing function for this algorism, which has greatly restrained its further development and application. An innovative test function model is designed in this paper and is used to test the algorism. It is proved that for evaluation of space partitioning method in certain applications, this test function has fairly obvious advantage.

  17. Functional Testing Protocols for Commercial Building Efficiency Baseline Modeling Software

    Energy Technology Data Exchange (ETDEWEB)

    Jump, David; Price, Phillip N.; Granderson, Jessica; Sohn, Michael

    2013-09-06

    This document describes procedures for testing and validating proprietary baseline energy modeling software accuracy in predicting energy use over the period of interest, such as a month or a year. The procedures are designed according to the methodology used for public domain baselining software in another LBNL report that was (like the present report) prepared for Pacific Gas and Electric Company: ?Commercial Building Energy Baseline Modeling Software: Performance Metrics and Method Testing with Open Source Models and Implications for Proprietary Software Testing Protocols? (referred to here as the ?Model Analysis Report?). The test procedure focuses on the quality of the software?s predictions rather than on the specific algorithms used to predict energy use. In this way the software vendor is not required to divulge or share proprietary information about how their software works, while enabling stakeholders to assess its performance.

  18. Evaluating rodent motor functions: Which tests to choose?

    Science.gov (United States)

    Schönfeld, Lisa-Maria; Dooley, Dearbhaile; Jahanshahi, Ali; Temel, Yasin; Hendrix, Sven

    2017-12-01

    Damage to the motor cortex induced by stroke or traumatic brain injury (TBI) can result in chronic motor deficits. For the development and improvement of therapies, animal models which possess symptoms comparable to the clinical population are used. However, the use of experimental animals raises valid ethical and methodological concerns. To decrease discomfort by experimental procedures and to increase the quality of results, non-invasive and sensitive rodent motor tests are needed. A broad variety of rodent motor tests are available to determine deficits after stroke or TBI. The current review describes and evaluates motor tests that fall into three categories: Tests to evaluate fine motor skills and grip strength, tests for gait and inter-limb coordination and neurological deficit scores. In this review, we share our thoughts on standardized data presentation to increase data comparability between studies. We also critically evaluate current methods and provide recommendations for choosing the best behavioral test for a new research line. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. The Functional Test for Agility Performance is a Reliable Quick Decision-Making Test for Skilled Water Polo Players

    Directory of Open Access Journals (Sweden)

    Tucher Guilherme

    2015-06-01

    Full Text Available The reliability of the Functional Test for Agility Performance has only been evaluated in water polo players in a small group of novice athletes. Thus, the aim of this study was to evaluate the reliability of the Functional Test for Agility Performance in skilled water polo players. Forty-two athletes (17.81 ± 3.24 years old with a minimum of 5 years of competitive experience (7.05 ± 2.84 years and playing at the national or international level were evaluated. The Functional Test for Agility Performance is characterized as a specific open decision-making test where a tested player moves as quickly as possible in accordance to a pass made by another player. The time spent in the test was measured by two experienced coaches. Descriptive statistics, repeated measures analysis of variance (ANOVA, 95% limit of agreement (LOA, intraclass correlation coefficient (ICC and standard error of measurements (SEM were used for data analysis. Athletes completed the Functional Test for Agility Performance in 4.15 0.47 s. The ICC value was 0.87 (95% IC = 0.80-0.92. The SEM varied between 0.24 and 0.38 s. The LOA was 1.20 s and the CV average considering each individual trial was 6%. The Functional Test for Agility Performance was shown to be a reliable quick decision-making test for skilled water polo players.

  20. Wada test for evaluation of language and memory function in medically intractable epilepsy

    International Nuclear Information System (INIS)

    Hong, Yong Kook; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Kim, Eun Kyung; Lee, Byung In; Huh, Kyun

    1992-01-01

    The Wada test was performed for lateralization of language and memory function, using intracarotid injection of Sodium Amytal. But the internal carotid artery (ICA) Wada test has some limitations for testing memory function. The posterior cerebral artery (PCA) Wada test has been designed to modify the ICA Wada test for testing memory function selectively. In our study, 10 patients out of 12 patients with intractable seizure underwent only the ICA Wada test and the other 2 patients underwent both the ICA and the selective PCA Wada test. In all 12 patients undergoing the ICA Wada test, we successfully localized speech and language dominance. Four of 12 patients who underwent the ICA Wada test for evaluation of memory function displayed superior memory functions in one hemisphere, but the other hemisphere also significantly contributed to memory. The selective PCA Wada test, performed in 2 patients, showed successful results of memory function test in both patients. Four of 12 patients underwent temporal lobectomy and there was no major post-operative language or memory deficits. We concluded that the ICA and PCA Wada tests are useful for preoperative evaluation of medically intractable epilepsy, and the PCA Wada test is valuable in memory evaluation in some patients who have high risk of postoperative global amnesia after temporal lobectomy following equivocal results of memory function by the ICA Wada test

  1. Wada test for evaluation of language and memory function in medically intractable epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Yong Kook; Chung, Tae Sub; Suh, Jung Ho; Kim, Dong Ik; Kim, Eun Kyung; Lee, Byung In; Huh, Kyun [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1992-05-15

    The Wada test was performed for lateralization of language and memory function, using intracarotid injection of Sodium Amytal. But the internal carotid artery (ICA) Wada test has some limitations for testing memory function. The posterior cerebral artery (PCA) Wada test has been designed to modify the ICA Wada test for testing memory function selectively. In our study, 10 patients out of 12 patients with intractable seizure underwent only the ICA Wada test and the other 2 patients underwent both the ICA and the selective PCA Wada test. In all 12 patients undergoing the ICA Wada test, we successfully localized speech and language dominance. Four of 12 patients who underwent the ICA Wada test for evaluation of memory function displayed superior memory functions in one hemisphere, but the other hemisphere also significantly contributed to memory. The selective PCA Wada test, performed in 2 patients, showed successful results of memory function test in both patients. Four of 12 patients underwent temporal lobectomy and there was no major post-operative language or memory deficits. We concluded that the ICA and PCA Wada tests are useful for preoperative evaluation of medically intractable epilepsy, and the PCA Wada test is valuable in memory evaluation in some patients who have high risk of postoperative global amnesia after temporal lobectomy following equivocal results of memory function by the ICA Wada test.

  2. Testing for Cognitive Function in Animals in a Regulatory Context

    Science.gov (United States)

    Superior cognitive functions have allowed the human species to dominate a world of incredible biological diversity. Threats to these essential capacities cannot be ignored, and a strategy is needed to evaluate the hazard posed by exposure to chemical and other agents. Because peo...

  3. Evaluation of liver function tests of HIV positive patients on ...

    African Journals Online (AJOL)

    Liver enzymes-alanine and aspartate aminotransferases and alkaline phosphatase (AST, ALT and ALP), bilirubin and serum proteins were determined using standard laboratory methods and these parameters were used to evaluate the liver function of human immunodeficiency virus (HIV)- positive patients receiving ...

  4. Pulmonary function test in traffic police personnel in Pondicherry.

    Science.gov (United States)

    Pal, Pravati; John, Robert A; Dutta, T K; Pal, G K

    2010-01-01

    Traffic policemen working in the busy traffic signal areas get exposed to the vehicular emissions for years together. The fumes, chemicals and particles present in the emission are reported to be damaging to the lung functions of these individuals. Since there were no data available on the PFT parameters of traffic police personnel of Pondicherry, this study was taken up to assess the effect of traffic air pollution on their pulmonary functions. PFT parameters were recorded in age- and BMI-matched 30 traffic police personnel (study group) and 30 general police personnel (control group) of male gender. As chronic smoking is known to be a critical factor in altering lung function, PFT parameters were compared between the smokers as well as nonsmokers of both the groups. In nonsmokers, there was significant decrease in VC (P traffic police personnel compared to the general police personnel. This may be due to exposure to vehicular pollution for several hours in a day for many years causing decreased functional capacity of the lungs and chronic smoking worsens the condition.

  5. Development and testing of new exchange correlation functionals

    DEFF Research Database (Denmark)

    Lundgård, Keld Troen

    , selectivity or similar of current chemical processes, or to make new technologies economical feasible. Kohn-Sham density functional theory (KS-DFT) has proven to be a powerful theory to find trends in current catalytic materials, which can empower a more informed search for better alternatives. KS-DFT relies...

  6. Assessment of biochemical liver function tests in relation to age ...

    African Journals Online (AJOL)

    Background and Objective: Multiorgan failure including liver dysfunction is a common finding in sickle cell anemia (SCA) patients, the cause of which is multifactorial with advancing age said to be a major determinant. There is a paucity of data on liver function among SCA patients in relation to age in northern Nigerian ...

  7. Reactor safety impact of functional test intervals: an application of Bayesian decision theory

    International Nuclear Information System (INIS)

    Buoni, F.B.

    1978-01-01

    Functional test intervals for important nuclear reactor systems can be obtained by viewing safety assessment as a decision process and functional testing as a Bayesian learning or information process. A preposterior analysis is used as the analytical model to find the preposterior expected reliability of a system as a function of test intervals. Persistent and transitory failure models are shown to yield different results. Functional tests of systems subject to persistent failure are effective in maintaining system reliability goals. Functional testing is not effective for systems subject to transitory failure; preventive maintenance must be used. A Bayesian posterior analysis of testing data can discriminate between persistent and transitory failure. The role of functional testing is seen to be an aid in assessing the future performance of reactor systems

  8. Testing of newly developed functional surfaces under pure sliding conditions

    DEFF Research Database (Denmark)

    Godi, Alessandro; Mohaghegh, Kamran; Grønbæk, J.

    2013-01-01

    the surfaces in an industrial context. In this paper, a number of experimental tests were performed using a novel test rig, called axial sliding test, simulating the contact of surfaces under pure sliding conditions. The aim of the experiments is to evaluate the frictional behavior of a new typology...... of textured surfaces, the so-called multifunctional surfaces, characterized by a plateau area able to bear loads and a deterministic pattern of lubricant pockets. Six surface typologies, namely three multifunctional and three machined using classical processes, were chosen to slide against a mirror....... The results comparison showed clearly how employing multifunctional surfaces can reduce friction forces up to 50 % at high normal loads compared to regularly ground or turned surfaces. Friction coefficients approximately equal to 0.12 were found for classically machined surfaces, whereas the values were 0...

  9. The chirally rotated Schroedinger functional. Theoretical expectations and perturbative tests

    International Nuclear Information System (INIS)

    Dalla Brida, Mattia

    2016-03-01

    The chirally rotated Schroedinger functional (χSF) with massless Wilson-type fermions provides an alternative lattice regularization of the Schroedinger functional (SF), with different lattice symmetries and a common continuum limit expected from universality. The explicit breaking of flavour and parity symmetries needs to be repaired by tuning the bare fermion mass and the coefficient of a dimension 3 boundary counterterm. Once this is achieved one expects the mechanism of automatic O(a) improvement to be operational in the χSF, in contrast to the standard formulation of the SF. This is expected to significantly improve the attainable precision for step-scaling functions of some composite operators. Furthermore, the χSF offers new strategies to determine finite renormalization constants which are traditionally obtained from chiral Ward identities. In this paper we consider a complete set of fermion bilinear operators, define corresponding correlation functions and explain the relation to their standard SF counterparts. We discuss renormalization and O(a) improvement and then use this set-up to formulate the theoretical expectations which follow from universality. Expanding the correlation functions to one-loop order of perturbation theory we then perform a number of non-trivial checks. In the process we obtain the action counterterm coefficients to one-loop order and reproduce some known perturbative results for renormalization constants of fermion bilinears. By confirming the theoretical expectations, this perturbative study lends further support to the soundness of the χSF framework and prepares the ground for non-perturbative applications.

  10. Avoidance test with Eisenia fetida as indicator for the habitat function of soils. Results of a laboratory comparison test

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K. [Fraunhofer Inst. for Molecular Biology and Applied Ecology, Schmallenberg (Germany); Achazi, R.; Warnecke, D. [Free Univ. of Berlin, Inst. for Biology, Berlin (Germany); Roembke, J. [ECT Oekotoxikologie GmbH, Floersheim (Germany)

    2003-07-01

    Intention, Goal, Scope, Background. The habitat function of soils is often assessed using the reproduction test with Eisenia fetida. As this test is rather labour-intensive, an alternative is needed which is less cost-intensive in terms of duration and workload, but gives reasonable results. The avoidance test with E. fetida is a suitable screening test meeting these criteria. However, before a novel test system can be generally recommended it has to be ensured that comparable results are acquired from different laboratories on the basis of the respective test guideline. Objective. The avoidance test with E. fetida was performed as laboratory comparison test. The results were compared with those of the earthworm acute and reproduction tests carried out with the same soils. Methods. The three tests were performed by three laboratories using eight contaminated soils and three control soils. The contaminated soils were mixed with the control soils to obtain different concentrations of the contamination. (orig.)

  11. An Effect Size Measure for Raju's Differential Functioning for Items and Tests

    Science.gov (United States)

    Wright, Keith D.; Oshima, T. C.

    2015-01-01

    This study established an effect size measure for differential functioning for items and tests' noncompensatory differential item functioning (NCDIF). The Mantel-Haenszel parameter served as the benchmark for developing NCDIF's effect size measure for reporting moderate and large differential item functioning in test items. The effect size of…

  12. Injury history, sex, and performance on the functional movement screen and Y balance test.

    Science.gov (United States)

    Chimera, Nicole J; Smith, Craig A; Warren, Meghan

    2015-05-01

    Research is limited regarding the effects of injury or surgery history and sex on the Functional Movement Screen (FMS) and Y Balance Test (YBT). To determine if injury or surgery history or sex affected results on the FMS and YBT. Cross-sectional study. Athletic training facilities. A total of 200 National Collegiate Athletic Association Division I female (n = 92; age = 20.0 ± 1.4 years, body mass index = 22.8 ± 3.1 kg/m(2)) and male (n = 108; age = 20.0 ± 1.5 years, body mass index = 27.0 ± 4.6 kg/m(2)) athletes were screened; 170 completed the FMS, and 190 completed the YBT. A self-reported questionnaire identified injury or surgery history and sex. The FMS assessed movement during the patterns of deep squat, hurdle step, in-line lunge, shoulder mobility, impingement-clearing test, straight-leg raise, trunk stability push-up, press-up clearing test, rotary stability, and posterior-rocking clearing test. The YBT assessed balance while participants reached in anterior, posteromedial, and posterolateral directions. The FMS composite score (CS; range, 0-21) and movement pattern score (range, 0-3), the YBT CS (% lower extremity length), and YBT anterior, posteromedial, and posterolateral asymmetry (difference between limbs in centimeters). Independent-samples t tests established differences in mean FMS CS, YBT CS, and YBT asymmetry. The Mann-Whitney U test identified differences in FMS movement patterns. We found lower overall FMS CSs for the following injuries or surgeries: hip (injured = 12.7 ± 3.1, uninjured = 14.4 ± 2.3; P = .005), elbow (injured = 12.1 ± 2.8, uninjured = 14.3 ± 2.4; P = .02), and hand (injured = 12.3 ± 2.9, uninjured = 14.3 ± 2.3; P = .006) injuries and shoulder surgery (surgery = 12.0 ± 1.0, no surgery = 14.3 ± 2.4; P lunge: P lunge: P = .01). Female athletes performed worse in FMS movement patterns for trunk (P in the lunge (P = .008), shoulder mobility (P < .001), and straight-leg raise (P < .001). Anterior asymmetry was greater

  13. Testing laboratories, its function in ensuring industrial safety

    International Nuclear Information System (INIS)

    Sanchez Fernandez, M.

    2015-01-01

    This article discusses and justifies the development of industrial laboratories (testing and calibration) in Spain, since its embryo, its creation and development, to the present day. Likewise, presents its interrelation with other agents, as well as the legislative and technical framework is application along to the years. Within this development of the sector, highlights the period of the conformity assessment, and consequently its relationship with Industrial safety. Finally, describes the organizational situation of the sector both nationally and internationally. (Author)

  14. The Effect of Obesity Degree on Childhood Pulmonary Function Tests

    Directory of Open Access Journals (Sweden)

    Emel Torun

    2014-09-01

    Full Text Available Background: Childhood obesity has become a global epidemic. It is related to several chronic diseases such as essential hypertension, type 2 diabetes mellitus, and renal disease. The relationship between the degree of obesity and lung functions is well defined in adults, but limited information is available about the childhood period. Aims: This study aims to determine the impact of the degree of obesity on the pulmonary functions of school children and adolescents. Study Design: Cross sectional study. Methods: Included in the study were a total of 170 school children and adolescents (9-17 years old referred to our paediatric outpatient clinic. Of these subjects, 42 were lean and non-obese (BMI % <85, 30 subjects were overweight (BMI % ˃85, <95, 34 subjects were obese (BMI % ˃95, <97, and 64 subjects were morbidly obese (BMI % ˃97. Anthropometric measurements were taken and spirometry was performed on all subjects. Forced vital capacity (FVC, forced expiratory volume in 1 second (FEV1, forced vital capacity 25-75 (FEV25-75 and peak expiratory flow (PEF were used to measure the ventilatory functions for all the subjects. Results: The groups showed no significant differences in age or gender. Despite no statistically significant differences in FEV1, FVC, or FEV1/FVC, there were significant reductions in PEF (p<0.001 and FEV25-75 (p<0.001 in the overweight, obese and morbidly obese subjects, when compared with those who were non-obese. Conclusion: Overweight, obese and morbidly obese children have no obstructive abnormalities compared with healthy lean subjects.

  15. Damage functions generation for polyatomic materials irradiated in test reactors

    International Nuclear Information System (INIS)

    Alberman, A.; Lesueur, D.

    1987-06-01

    Neutron exposure parameters in polyatomic materials is of great importance for fusion technology programs. The COMPOSI code computes the number of displaced atoms of sub-lattice ''j'' induced by one atom of sub-lattice ''i'' either by direct collision or through intermediate knocked atom. The code uses Lindhard equations; it is solved by iterative process. The atomic displacements cross-sections, as a function of neutron energy are derived by folding previous results with ''i'' type PKA. Moreover the COMPOSI code may include recoils from charged particles e.g.: Alpha + Triton from Li 6 capture in Li Al 0 2 . These responses in various spectra are discussed [fr

  16. Performance-intensity functions of Mandarin word recognition tests in noise: test dialect and listener language effects.

    Science.gov (United States)

    Liu, Danzheng; Shi, Lu-Feng

    2013-06-01

    This study established the performance-intensity function for Beijing and Taiwan Mandarin bisyllabic word recognition tests in noise in native speakers of Wu Chinese. Effects of the test dialect and listeners' first language on psychometric variables (i.e., slope and 50%-correct threshold) were analyzed. Thirty-two normal-hearing Wu-speaking adults who used Mandarin since early childhood were compared to 16 native Mandarin-speaking adults. Both Beijing and Taiwan bisyllabic word recognition tests were presented at 8 signal-to-noise ratios (SNRs) in 4-dB steps (-12 dB to +16 dB). At each SNR, a half list (25 words) was presented in speech-spectrum noise to listeners' right ear. The order of the test, SNR, and half list was randomized across listeners. Listeners responded orally and in writing. Overall, the Wu-speaking listeners performed comparably to the Mandarin-speaking listeners on both tests. Compared to the Taiwan test, the Beijing test yielded a significantly lower threshold for both the Mandarin- and Wu-speaking listeners, as well as a significantly steeper slope for the Wu-speaking listeners. Both Mandarin tests can be used to evaluate Wu-speaking listeners. Of the 2, the Taiwan Mandarin test results in more comparable functions across listener groups. Differences in the performance-intensity function between listener groups and between tests indicate a first language and dialectal effect, respectively.

  17. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis

    OpenAIRE

    Tilanus, T. B. M.; Groothuis, J. T.; TenBroek-Pastoor, J. M. C.; Feuth, T. B.; Heijdra, Y. F.; Slenders, J. P. L.; Doorduin, J.; Van Engelen, B. G.; Kampelmacher, M. J.; Raaphorst, J.

    2017-01-01

    BACKGROUND: Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown which respiratory function test predicts an appropriate timing of the initiation of NIV. METHODS: We analysed, retrospectively, serial data of five respiratory function tests: forced vital capacity...

  18. A portable generic elementary function package in Ada and an accurate test suite

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Ping Tak Peter.

    1990-11-01

    A comprehensive set of elementary functions has been implemented portably in Ada. The high accuracy of the implementation has been confirmed by rigorous analysis. Moreover, we present new test methods that are efficient and offer a high resolution of 0.005 unit in the last place. These test methods have been implemented portably here and confirm the accuracy of our implemented functions. Reports on the accuracy of other function libraries obtained by our test programs are also presented. 26 refs., 9 tabs.

  19. MK-III function tests in JOYO. Dump heat exchanger (DHX)

    International Nuclear Information System (INIS)

    Kawahara, Hirotaka; Isozaki, Kazunori; Ishii, Takayuki; Ichige, Satoshi; Sakaba, Hideo; Nakai, Satoru; Nose, Shouiti

    2004-06-01

    A key part of the upgrade of the experimental fast reactor JOYO to the MK-III design was the replacement of the dump heat exchangers. MK-III function tests (SKS-1) of the new dump heat exchangers were carried out from August 27, 2001 through September 13, 2001. The major results of the function tests of the dump heat exchangers were as follows: (1) Air flow of the main blower with an inlet vane opening of 50% was confirmed to exceed the design rated flow of 7,700 m 3 /min. It was also demonstrated that an inlet vane opening of 100% provides about 130% of the design rated flow. This is because the new DHX flow route has more low pressure loss than the design value. (2) Tests of the air flow of the main blower demonstrated that with a fully opened inlet damper, a full opened outlet damper and an inlet vane opening of 0% provides about 5% of the design rated flow. (3) Free flow coast down characteristics of the main blower achieved an inlet vane 0% opening in an average of 7.9 seconds. Revolutions per minute of the main blower reached zero in an average of 8.7 seconds. The delay time from the opening of the vacuum contact breaker to the air flow decrease was approximately 1 second. This was a more conservative value than the 5 seconds assumed in design thermal transient analyses. (4) The loudest noise occurred with the main blower operating with a 25% inlet vane opening. At that time, the noise around the main blower was approximately 100 dB, and in the surrounding monitoring area boundary, the noise was 50 dB. This was confirmed to be within the standard of the Ibaraki prefectural ordinance. (5) Although the MK-III inlet vane and inlet damper drive unit was bigger than the MK-II unit, the accumulator tank was confirmed to provide sufficient volume during a compression air loss event. (author)

  20. An Evaluation of the Sniffer Global Optimization Algorithm Using Standard Test Functions

    Science.gov (United States)

    Butler, Roger A. R.; Slaminka, Edward E.

    1992-03-01

    The performance of Sniffer—a new global optimization algorithm—is compared with that of Simulated Annealing. Using the number of function evaluations as a measure of efficiency, the new algorithm is shown to be significantly better at finding the global minimum of seven standard test functions. Several of the test functions used have many local minima and very steep walls surrounding the global minimum. Such functions are intended to thwart global minimization algorithms.

  1. TESTING SOME PEDO-TRANSFER FUNCTIONS (PTFS IN APULIA REGION

    Directory of Open Access Journals (Sweden)

    Floriano Buccigrossi

    2009-03-01

    Full Text Available The knowledge of soil water retention vs. soil water matric potential is used to study irrigation and drainage schedules, soil water storage capacity (plant available water, solute movement, plant growth and water stress. The hydraulic soil properties measuring is expensive, laborious and takes too long time, so, frequently, matemathic models, called pedo-transfer functions (PTFs are utilized to estimate hydraulic soil properties through soil chimical and phisical characteristics. Six pedo-transfer functions have been evaluated (Gupta & Larson, 1979; Rawls et al., 1982; De Jong et al., 1983; Rawls & Brakensiek, 1985; Saxton et al., 1986; Vereecken et al., 1989 by comparing estimated with measured soil moisture values at soil water matric potential of –33 and –1500 kPa of 361 soil samples collected from 185 pedons of Apulia Region (South Italy, having various combinations of particle-size distribution, soil organic matter content and bulk density. Accuracy of the soil moisture predictions have been evaluated by statistic indexes such as Weighted stantard error (WSEE, Mean Deviation (MD, Root Mean Squared Deviation (RMSD and the determination coefficient (R2 between estimated and measured water retention values. The Rawls PTF model demostrated to have the lowest values of WSEE, MD and RMSD indexes (0.044, -0.007 and 0.059 m3 H2O m-3 soil, respectively at –33 Kpa soil water matric potential (Field Capacity, while for estimating soil moisture at the Wilting Point (-1500 kPa Rawls & Brakensiek model is adequate (WSEE, MD and RMSD of 0.034, -0.016 and 0.046 m3 H2O m-3 soil. De Jong, Saxton and Rawls & Brakensiek models, at –33 kPa soil water matric potential and Gupta & Larson and De Jong models at –1500 kPa soil water matric potential, showed the highest statistic errors.

  2. The Sandia MEMS Passive Shock Sensor : FY08 testing for functionality, model validation, and technology readiness.

    Energy Technology Data Exchange (ETDEWEB)

    Walraven, Jeremy Allen; Blecke, Jill; Baker, Michael Sean; Clemens, Rebecca C.; Mitchell, John Anthony; Brake, Matthew Robert; Epp, David S.; Wittwer, Jonathan W.

    2008-10-01

    This report summarizes the functional, model validation, and technology readiness testing of the Sandia MEMS Passive Shock Sensor in FY08. Functional testing of a large number of revision 4 parts showed robust and consistent performance. Model validation testing helped tune the models to match data well and identified several areas for future investigation related to high frequency sensitivity and thermal effects. Finally, technology readiness testing demonstrated the integrated elements of the sensor under realistic environments.

  3. HF-voltage testing of accelerating system functional model

    International Nuclear Information System (INIS)

    Gladkov, A.V.; Stepanov, V.B.

    1989-01-01

    Owing to ambiguity in interpreting the notion of the electron strength of the operating HF device in an acceleator a technique of measurements and result processing, based on statistical analysis of the data is suggested. Experimental testing on electric strength of structures with HF focusing was carried out using a bench in the form of a cylindrical vacuum container inside which a double H-resonator with HF quadrupole electrodes without surface modulation was installed. The dependences obtained permit to evaluate the bahaviour of the HF device from the viewpoint of electric strength and radiation hazard for the whole range of possible values of voltage on the basis of data on the frequency of breakdowns and radiation situation only in one experimental point. 12 refs.; 8 figs

  4. Impact of proof test interval and coverage on probability of failure of safety instrumented function

    International Nuclear Information System (INIS)

    Jin, Jianghong; Pang, Lei; Hu, Bin; Wang, Xiaodong

    2016-01-01

    Highlights: • Introduction of proof test coverage makes the calculation of the probability of failure for SIF more accurate. • The probability of failure undetected by proof test is independently defined as P TIF and calculated. • P TIF is quantified using reliability block diagram and simple formula of PFD avg . • Improving proof test coverage and adopting reasonable test period can reduce the probability of failure for SIF. - Abstract: Imperfection of proof test can result in the safety function failure of safety instrumented system (SIS) at any time in its life period. IEC61508 and other references ignored or only elementarily analyzed the imperfection of proof test. In order to further study the impact of the imperfection of proof test on the probability of failure for safety instrumented function (SIF), the necessity of proof test and influence of its imperfection on system performance was first analyzed theoretically. The probability of failure for safety instrumented function resulted from the imperfection of proof test was defined as probability of test independent failures (P TIF ), and P TIF was separately calculated by introducing proof test coverage and adopting reliability block diagram, with reference to the simplified calculation formula of average probability of failure on demand (PFD avg ). Research results show that: the shorter proof test period and the higher proof test coverage indicate the smaller probability of failure for safety instrumented function. The probability of failure for safety instrumented function which is calculated by introducing proof test coverage will be more accurate.

  5. Evaluation of liver function tests in scleroderma patients.

    Science.gov (United States)

    Salem, Gehan Ibrahim Abdelrazek; Abdulrahman, Awni Ali

    2012-08-01

    Systemic sclerosis is a clinically heterogeneous, systemic disorder which affects the connective tissue of the skin, internal organs, and the walls of blood vessels. It is characterized by alterations of the microvasculature, disturbances of the immune system and by massive deposition of collagen and other matrix substances in the connective tissue. This study was done to evaluate the frequency of liver disease in patients with scleroderma and, secondarily, to study the frequency of infection of hepatitis B and C virus in these patients and determine frequency of serum auto-antibodies in this disease. We studied patients with scleroderma, localized or systemic, in the outpatient clinic of rheumatology and dermatology departments, at King Khalid University Hospital. As for a comparison, healthy persons coming to the clinic with the same mean age were considered as control group. Forty patients with the diagnosis of scleroderma included in this work, 35% had elevated gamma-glutamyl-transferase (γ-GT), 30% had elevated alkaline phosphatase (AP) and in 17.5%, the alanine-amino-transferase (ALT) was above the reference values. The ALT had changed to be more in scleroderma patients than in controls. Twenty percent (20%) of the patients tested positive for anti-smooth muscle antibodies (anti-SMA) and only one patient had anti-mitochondrial antibodies (AMA). There was no statistical difference between the two groups regarding antibody testing. Anti-HCV antibodies were observed in one patient, and HBsAg was detected in another scleroderma patient. There was no patient with clinically significant hepatic disease. In this study, although changes in liver enzymes in patients with scleroderma were not uncommon, there was no scleroderma patient with clinical manifestations of liver disease.

  6. 75 FR 29962 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Science.gov (United States)

    2010-05-28

    ... SF50 airplanes. 1. Function and Reliability Testing Flight tests: In place of 14 CFR part 21.35(b)(2... Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed special..., 1951, and deleted the service test requirements in Section 3.19 for airplanes of 6,000 pounds maximum...

  7. RECORDS REACHING RECORDING DATA TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    G. W. L. Gresik

    2013-07-01

    Full Text Available The goal of RECORDS (Reaching Recording Data Technologies is the digital capturing of buildings and cultural heritage objects in hard-to-reach areas and the combination of data. It is achieved by using a modified crane from film industry, which is able to carry different measuring systems. The low-vibration measurement should be guaranteed by a gyroscopic controlled advice that has been , developed for the project. The data were achieved by using digital photography, UV-fluorescence photography, infrared reflectography, infrared thermography and shearography. Also a terrestrial 3D laser scanner and a light stripe topography scanner have been used The combination of the recorded data should ensure a complementary analysis of monuments and buildings.

  8. Records Reaching Recording Data Technologies

    Science.gov (United States)

    Gresik, G. W. L.; Siebe, S.; Drewello, R.

    2013-07-01

    The goal of RECORDS (Reaching Recording Data Technologies) is the digital capturing of buildings and cultural heritage objects in hard-to-reach areas and the combination of data. It is achieved by using a modified crane from film industry, which is able to carry different measuring systems. The low-vibration measurement should be guaranteed by a gyroscopic controlled advice that has been , developed for the project. The data were achieved by using digital photography, UV-fluorescence photography, infrared reflectography, infrared thermography and shearography. Also a terrestrial 3D laser scanner and a light stripe topography scanner have been used The combination of the recorded data should ensure a complementary analysis of monuments and buildings.

  9. The 1-min sit-to-stand test--A simple functional capacity test in cystic fibrosis?

    Science.gov (United States)

    Radtke, Thomas; Puhan, Milo A; Hebestreit, Helge; Kriemler, Susi

    2016-03-01

    We aimed to assess the measurement properties and the minimal important difference (MID) of the 1-min sit-to-stand (STS) test in cystic fibrosis (CF). Patients with CF were tested during a pulmonary rehabilitation program. Five STS tests were performed during the program; two tests at the beginning (STS0 and STS1) and three tests at the end (STS2a-2c). Exercise capacity, pulmonary function, and health-related quality of life (HRQoL) and patient-reported health status were measured at the beginning and end of the program. We calculated overall mean, standard deviation, coefficient of variation (CV), and intraclass correlation coefficient (ICC) of the STS test. The MID was calculated using anchor-based and distributional methods. Fourteen participants (8 female, mean age 30.4±6.1years) were included. STS test performance increased significantly from STS0 to STS1 indicative of a learning effect. Test-retest reliability for the subsequent STS2a-2c tests was excellent (ICC 0.98, 95% CI 0.96-0.99). The estimated MID for the STS test was 5 repetitions. STS test performance was responsive to change (effect size of 0.97) and correlated with exercise capacity (r=0.63-0.73) and with the physical functioning HRQoL scale (r=0.72). The 1-min STS test appears to be a reliable, valid, and feasible test to measure functional capacity in patients with CF. Copyright © 2015 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  10. Development of Applicable Test Scenario by the Grid Simulator of a Functional Test Bench

    DEFF Research Database (Denmark)

    Farajzadehbibalan, Saber

    In this thesis, a data-driven testing procedure for wind turbine generators is developed. The procedure generates a data set for a hardware-in-the-loop testing setup at a test facility. The goal is to shorten validation process, prevent damage from highly dangerous grid tests, and conduct different...... tests. The proposed procedure deploys a multivariate statistical model of the power grid derived from the wind farm's standpoint. A practical data set of an operational wind farm is available which is logged during the years of 2013 and 2014 for model identification and validation, respectively....... The first step of modeling is deriving the model from the standpoint of an arbitrary wind turbine generator utilizing dynamic principal component analysis. The model is the transformed data samples into a new projected space, i.e. latent space, as the combination of the principal components and the scores...

  11. Performance of exchange-correlation functionals in density functional theory calculations for liquid metal: A benchmark test for sodium

    Science.gov (United States)

    Han, Jeong-Hwan; Oda, Takuji

    2018-04-01

    The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.

  12. PEP Run Report for Simulant Shakedown/Functional Testing

    Energy Technology Data Exchange (ETDEWEB)

    Josephson, Gary B.; Geeting, John GH; Bredt, Ofelia P.; Burns, Carolyn A.; Golovich, Elizabeth C.; Guzman-Leong, Consuelo E.; Kurath, Dean E.; Sevigny, Gary J.

    2009-12-29

    Pacific Northwest National Laboratory (PNNL) has been tasked by Bechtel National Inc. (BNI) on the River Protection Project-Waste Treatment Plant (RPP-WTP) project to perform research and development activities to resolve technical issues identified for the Pretreatment Facility (PTF). The Pretreatment Engineering Platform (PEP) was designed, constructed, and operated as part of a plan to respond to issue M12, "Undemonstrated Leaching Processes." The PEP is a 1/4.5-scale test platform designed to simulate the WTP pretreatment caustic leaching, oxidative leaching, ultrafiltration solids concentration, and slurry washing processes. The PEP replicates the WTP leaching processes using prototypic equipment and control strategies. The PEP also includes non-prototypic ancillary equipment to support the core processing. Two operating scenarios are currently being evaluated for the ultrafiltration process (UFP) and leaching operations. The first scenario has caustic leaching performed in the UFP-2 ultrafiltration feed vessels (i.e., vessel UFP-VSL-T02A in the PEP; and vessels UFP-VSL-00002A and B in the WTP PTF). The second scenario has caustic leaching conducted in the UFP-1 ultrafiltration feed preparation vessels (i.e., vessels UFP-VSL-T01A and B in the PEP; vessels UFP-VSL-00001A and B in the WTP PTF). In both scenarios, 19-M sodium hydroxide solution (NaOH, caustic) is added to the waste slurry in the vessels to leach solid aluminum compounds (e.g., gibbsite, boehmite). Caustic addition is followed by a heating step that uses direct injection of steam to accelerate the leach process. Following the caustic leach, the vessel contents are cooled using vessel cooling jackets and/or external heat exchangers. The main difference between the two scenarios is that for leaching in UFP-1, the 19-M NaOH is added to un-concentrated waste slurry (3-8 wt% solids), while for leaching in UFP-2, the slurry is concentrated to nominally 20 wt% solids using cross-flow ultrafiltration

  13. A note of spaces of test and generalized functions of Poisson white noise

    OpenAIRE

    Lytvynov, E.

    2006-01-01

    The paper is devoted to construction and investigation of some riggings of the $L^2$-space of Poisson white noise. A particular attention is paid to the existence of a continuous version of a function from a test space, and to the property of an algebraic structure under pointwise multiplication of functions from a test space.

  14. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  15. A real-life, ecologically valid test of executive functioning : The executive secretarial task

    NARCIS (Netherlands)

    Lamberts, Kirsten F.; Evans, Jonathan J.; Spikman, Jacoba M.

    2010-01-01

    A major goal of neuropsychological assessment is predicting a person's level of functioning in daily life. Making predictions about everyday executive functioning based on tests is problematic because of the contrast between demands made in the test environment and demands made in everyday life

  16. The most frequently used tests for assessing executive functions in aging

    Directory of Open Access Journals (Sweden)

    Camila de Assis Faria

    Full Text Available There are numerous neuropsychological tests for assessing executive functions in aging, which vary according to the different domains assessed. OBJECTIVE: To present a systematic review of the most frequently used instruments for assessing executive functions in older adults with different educational levels in clinical and experimental research. METHODS: We searched for articles published in the last five years, using the PubMed database with the following terms: "neuropsychological tests", "executive functions", and "mild cognitive impairment". There was no language restriction. RESULTS: 25 articles fulfilled all the inclusion criteria. The seven neuropsychological tests most frequently used to evaluate executive functions in aging were: [1] Trail Making Test (TMT Form B; [2] Verbal Fluency Test (VFT - F, A and S; [3] VFT Animals category; [4] Clock Drawing Test (CDT; [5] Digits Forward and Backward subtests (WAIS-R or WAIS-III; [6] Stroop Test; and [7] Wisconsin Card Sorting Test (WCST and its variants. The domains of executive functions most frequently assessed were: mental flexibility, verbal fluency, planning, working memory, and inhibitory control. CONCLUSION: The study identified the tests and domains of executive functions most frequently used in the last five years by research groups worldwide to evaluate older adults. These results can direct future research and help build evaluation protocols for assessing executive functions, taking into account the different educational levels and socio-demographic profiles of older adults in Brazil.

  17. A physical function test for use in the intensive care unit: validity, responsiveness, and predictive utility of the physical function ICU test (scored).

    Science.gov (United States)

    Denehy, Linda; de Morton, Natalie A; Skinner, Elizabeth H; Edbrooke, Lara; Haines, Kimberley; Warrillow, Stephen; Berney, Sue

    2013-12-01

    Several tests have recently been developed to measure changes in patient strength and functional outcomes in the intensive care unit (ICU). The original Physical Function ICU Test (PFIT) demonstrates reliability and sensitivity. The aims of this study were to further develop the original PFIT, to derive an interval score (the PFIT-s), and to test the clinimetric properties of the PFIT-s. A nested cohort study was conducted. One hundred forty-four and 116 participants performed the PFIT at ICU admission and discharge, respectively. Original test components were modified using principal component analysis. Rasch analysis examined the unidimensionality of the PFIT, and an interval score was derived. Correlations tested validity, and multiple regression analyses investigated predictive ability. Responsiveness was assessed using the effect size index (ESI), and the minimal clinically important difference (MCID) was calculated. The shoulder lift component was removed. Unidimensionality of combined admission and discharge PFIT-s scores was confirmed. The PFIT-s displayed moderate convergent validity with the Timed "Up & Go" Test (r=-.60), the Six-Minute Walk Test (r=.41), and the Medical Research Council (MRC) sum score (rho=.49). The ESI of the PFIT-s was 0.82, and the MCID was 1.5 points (interval scale range=0-10). A higher admission PFIT-s score was predictive of: an MRC score of ≥48, increased likelihood of discharge home, reduced likelihood of discharge to inpatient rehabilitation, and reduced acute care hospital length of stay. Scoring of sit-to-stand assistance required is subjective, and cadence cutpoints used may not be generalizable. The PFIT-s is a safe and inexpensive test of physical function with high clinical utility. It is valid, responsive to change, and predictive of key outcomes. It is recommended that the PFIT-s be adopted to test physical function in the ICU.

  18. Reach-to-grasp movement as a minimization process.

    Science.gov (United States)

    Yang, Fang; Feldman, Anatol G

    2010-02-01

    It is known that hand transport and grasping are functionally different but spatially coordinated components of reach-to-grasp (RTG) movements. As an extension of this notion, we suggested that body segments involved in RTG movements are controlled as a coherent ensemble by a global minimization process associated with the necessity for the hand to reach the motor goal. Different RTG components emerge following this process without pre-programming. Specifically, the minimization process may result from the tendency of neuromuscular elements to diminish the spatial gap between the actual arm-hand configuration and its virtual (referent) configuration specified by the brain. The referent configuration is specified depending on the object shape, localization, and orientation. Since the minimization process is gradual, it can be interrupted and resumed following mechanical perturbations, at any phase during RTG movements, including hand closure. To test this prediction of the minimization hypothesis, we asked subjects to reach and grasp a cube placed within the reach of the arm. Vision was prevented during movement until the hand returned to its initial position. As predicted, by arresting wrist motion at different points of hand transport in randomly selected trials, it was possible to halt changes in hand aperture at any phase, not only during hand opening but also during hand closure. Aperture changes resumed soon after the wrist was released. Another test of the minimization hypothesis was made in RTG movements to an object placed beyond the reach of the arm. It has previously been shown (Rossi et al. in J Physiol 538:659-671, 2002) that in such movements, the trunk motion begins to contribute to hand transport only after a critical phase when the shifts in the referent arm configuration have finished (at about the time when hand velocity is maximal). The minimization rule suggests that when the virtual contribution of the arm to hand transport is completed

  19. Quantum tests for the linearity and permutation invariance of Boolean functions

    Energy Technology Data Exchange (ETDEWEB)

    Hillery, Mark [Department of Physics, Hunter College of the City University of New York, 695 Park Avenue, New York, New York 10021 (United States); Andersson, Erika [SUPA, School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom)

    2011-12-15

    The goal in function property testing is to determine whether a black-box Boolean function has a certain property or is {epsilon}-far from having that property. The performance of the algorithm is judged by how many calls need to be made to the black box in order to determine, with high probability, which of the two alternatives is the case. Here we present two quantum algorithms, the first to determine whether the function is linear and the second to determine whether it is symmetric (invariant under permutations of the arguments). Both require order {epsilon}{sup -2/3} calls to the oracle, which is better than known classical algorithms. In addition, in the case of linearity testing, if the function is linear, the quantum algorithm identifies which linear function it is. The linearity test combines the Bernstein-Vazirani algorithm and amplitude amplification, while the test to determine whether a function is symmetric uses projective measurements and amplitude amplification.

  20. Comparison of functional ramp walk test and 6-min walk test in healthy volunteers: A new approach in functional capacity evaluation

    Directory of Open Access Journals (Sweden)

    Manivel Arumugam

    2017-01-01

    Full Text Available Objective: Inclined surfaces or ramps are the common obstacles faced by elderly and cardiopulmonary disabled in accessing public amenities. Ramp walking is one of the most common functional demands to be met by a common man in the industrialized world. To assess the functional (uphill walking capacity, we need a different functional stress test over the routinely used 6-min walk test (6MWT. Hence, a new 3-min steep ramp walk test (3MRWT was constructed to meet the demands similar to an uphill walk and to provide more functional stress than routinely used 6MWT. Methodology: The observational, crossover study design was adopted for this study. Fifteen healthy participants (8 males, 7 females performed both tests in a randomized order with a washout time of 6 h in between the tests. Walking distance to both ramp and ground, heart rate, blood pressure, saturation (SpO2, dyspnea, and fatigue with Borg exertion scale were compared prior and after the two walk tests. Results: The average distances covered in 6MWT were 510.5 ± 55.06 and 440.65 ± 25.08 meters and in 3MRWT were 270.18 ± 30.8, 230.05 ± 15.06 meters for male and female respectively. The difference between 3MRWT and 6MWT distances covered by the participants was statistically significant (t = 0.893. The mean difference between the heart rate, saturation and perceptions were highly significant (P < 0.001. Conclusion: The study results show that 3MRWT is valid over routinely administered 6MWT and may provide greater functional stress (uphill or ramp walk capacity in a shorter duration in healthy individuals in assessing the maximal functional capacity in a ramp or uphill walking.

  1. ALMA Telescope Reaches New Heights

    Science.gov (United States)

    2009-09-01

    The ALMA (Atacama Large Millimeter/submillimeter Array) astronomical observatory took another step forward and upward, as one of its state-of-the-art antennas was carried for the first time to Chile's 16,500-foot-high plateau of Chajnantor on the back of a giant, custom-built transporter. The 40-foot-diameter antenna, weighing about 100 tons, was moved to ALMA's high-altitude Array Operations Site, where the extremely dry and rarefied air is ideal for observing the Universe. The conditions at the Array Operations Site on Chajnantor, while excellent for astronomy, are also very harsh. Only about half as much oxygen is available as at sea level, making it very difficult to work there. This is why ALMA's antennas are assembled and tested at the lower 9,500-foot altitude of the ALMA Operations Support Facility (OSF). It was from this relatively hospitable base camp that the ALMA antenna began its journey to the high Chajnantor site. "The successful transport of the first ALMA Antenna to the high site marks the start of the next phase of the project. Now that we are starting to move the ALMA antennas to the high site, the real work begins and the exciting part is just beginning," said Adrian Russell, North American ALMA Project Manager. The antenna's trip began when one of the two ALMA transporters lifted the antenna onto its back, carrying its heavy load along the 17-mile road from the Operations Support Facility up to the Array Operations Site. While the transporter is capable of speeds of up to 8 miles per hour when carrying an antenna, this first journey was made more slowly to ensure that everything worked as expected, taking about seven hours. The ALMA antennas use state-of-the-art technology, and are the most advanced submillimeter-wavelength antennas ever made. They are designed to operate fully exposed in the harsh conditions of the Array Operations Site, to survive strong winds and extreme temperatures, to point precisely enough that they could pick out a golf

  2. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    Science.gov (United States)

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  3. REACH and nanomaterials: current status

    International Nuclear Information System (INIS)

    Alessandrelli, Maria; Di Prospero Fanghella, Paola; Polci, Maria Letizia; Castelli, Stefano; Pettirossi, Flavio

    2015-01-01

    New challenges for regulators are emerging about a specific assessment and appropriate management of the potential risks of nanomaterials. In the framework of European legislation on chemicals, Regulation (EC) No. 1907/2006 REACH aims to ensure the safety of human health and the environment through the collection of information on the physico-chemical characteristics of the substances and on their profile (eco) toxicological and the identification of appropriate risk management linked to 'exposure to these substances without impeding scientific progress and the competitiveness of industry. In order to cover the current shortage of information on the safety of nanomaterials and tackle the acknowledged legal vacuum, are being a rich activities, carried out both by regulators both by stake holders, and discussions on the proposals for adapting the European regulatory framework for chemicals . The European Commission is geared to strengthen the REACH Regulation by means of updates of its annexes. The importance of responding to the regulatory requirements has highlighted the need for cooperation between European organizations, scientists and industries to promote and ensure the safe use of nanomaterials. [it

  4. Incidence of Pneumothorax in Patients With Lymphangioleiomyomatosis Undergoing Pulmonary Function and Exercise Testing.

    Science.gov (United States)

    Taveira-DaSilva, Angelo M; Julien-Williams, Patricia; Jones, Amanda M; Moss, Joel

    2016-07-01

    Because pneumothorax is frequent in lymphangioleiomyomatosis, patients have expressed concerns regarding the risk of pneumothorax associated with pulmonary function or exercise testing. Indeed, pneumothorax has been reported in patients with lung disease after both of these tests. The aim of this study was to determine the incidence of pneumothorax in patients with lymphangioleiomyomatosis during admissions to the National Institutes of Health Clinical Research Center between 1995 and 2015. Medical records were reviewed to identify patients who had a pneumothorax during their stay at the National Institutes of Health. A total of 691 patients underwent 4,523 pulmonary function tests and 1,900 exercise tests. Three patients developed pneumothorax after pulmonary function tests and/or exercise tests. The incidence of pneumothorax associated with lung function testing was 0.14 to 0.29 of 100 patients or 0.02 to 0.04 of 100 tests. The incidence of pneumothorax in patients undergoing exercise testing was 0.14 to 0.28 of 100 patients or 0.05 to 0.10 of 100 tests. The risk of pneumothorax associated with pulmonary function or exercise testing in patients with lymphangioleiomyomatosis is low. Published by Elsevier Inc.

  5. Vestibular feedback maintains reaching accuracy during body movement

    Science.gov (United States)

    Reynolds, Raymond F.

    2016-01-01

    Key points Reaching movements can be perturbed by vestibular input, but the function of this response is unclear.Here, we applied galvanic vestibular stimulation concurrently with real body movement while subjects maintained arm position either fixed in space or fixed with respect to their body.During the fixed‐in‐space conditions, galvanic vestibular stimulation caused large changes in arm trajectory consistent with a compensatory response to maintain upper‐limb accuracy in the face of body movement.Galvanic vestibular stimulation responses were absent during the body‐fixed task, demonstrating task dependency in vestibular control of the upper limb.The results suggest that the function of vestibular‐evoked arm movements is to maintain the accuracy of the upper limb during unpredictable body movement, but only when reaching in an earth‐fixed reference frame. Abstract When using our arms to interact with the world, unintended body motion can introduce movement error. A mechanism that could detect and compensate for such motion would be beneficial. Observations of arm movements evoked by vestibular stimulation provide some support for this mechanism. However, the physiological function underlying these artificially evoked movements is unclear from previous research. For such a mechanism to be functional, it should operate only when the arm is being controlled in an earth‐fixed rather than a body‐fixed reference frame. In the latter case, compensation would be unnecessary and even deleterious. To test this hypothesis, subjects were gently rotated in a chair while being asked to maintain their outstretched arm pointing towards either earth‐fixed or body‐fixed memorized targets. Galvanic vestibular stimulation was applied concurrently during rotation to isolate the influence of vestibular input, uncontaminated by inertial factors. During the earth‐fixed task, galvanic vestibular stimulation produced large polarity‐dependent corrections in arm

  6. Clinical Functional Capacity Testing in Patients With Facioscapulohumeral Muscular Dystrophy: Construct Validity and Interrater Reliability of Antigravity Tests.

    Science.gov (United States)

    Rijken, Noortje H; van Engelen, Baziel G; Weerdesteyn, Vivian; Geurts, Alexander C

    2015-12-01

    To evaluate the construct validity and interrater reliability of 4 simple antigravity tests in a small group of patients with facioscapulohumeral muscular dystrophy (FSHD). Case-control study. University medical center. Patients with various severity levels of FSHD (n=9) and healthy control subjects (n=10) were included (N=19). Not applicable. A 4-point ordinal scale was designed to grade performance on the following 4 antigravity tests: sit to stance, stance to sit, step up, and step down. In addition, the 6-minute walk test, 10-m walking test, Berg Balance Scale, and timed Up and Go test were administered as conventional tests. Construct validity was determined by linear regression analysis using the Clinical Severity Score (CSS) as the dependent variable. Interrater agreement was tested using a κ analysis. Patients with FSHD performed worse on all 4 antigravity tests compared with the controls. Stronger correlations were found within than between test categories (antigravity vs conventional). The antigravity tests revealed the highest explained variance with regard to the CSS (R(2)=.86, P=.014). Interrater agreement was generally good. The results of this exploratory study support the construct validity and interrater reliability of the proposed antigravity tests for the assessment of functional capacity in patients with FSHD taking into account the use of compensatory strategies. Future research should further validate these results in a larger sample of patients with FSHD. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Biologic variability and correlation of platelet function testing in healthy dogs.

    Science.gov (United States)

    Blois, Shauna L; Lang, Sean T; Wood, R Darren; Monteith, Gabrielle

    2015-12-01

    Platelet function tests are influenced by biologic variability, including inter-individual (CVG ) and intra-individual (CVI ), as well as analytic (CVA ) variability. Variability in canine platelet function testing is unknown, but if excessive, would make it difficult to interpret serial results. Additionally, the correlation between platelet function tests is poor in people, but not well described in dogs. The aims were to: (1) identify the effect of variation in preanalytic factors (venipuncture, elapsed time until analysis) on platelet function tests; (2) calculate analytic and biologic variability of adenosine diphosphate (ADP) and arachidonic acid (AA)-induced thromboelastograph platelet mapping (TEG-PM), ADP-, AA-, and collagen-induced whole blood platelet aggregometry (WBA), and collagen/ADP and collagen/epinephrine platelet function analysis (PFA-CADP, PFA-CEPI); and (3) determine the correlation between these variables. In this prospective observational trial, platelet function was measured once every 7 days, for 4 consecutive weeks, in 9 healthy dogs. In addition, CBC, TEG-PM, WBA, and PFA were performed. Overall coefficients of variability ranged from 13.3% to 87.8% for the platelet function tests. Biologic variability was highest for AA-induced maximum amplitude generated during TEG-PM (MAAA; CVG = 95.3%, CVI = 60.8%). Use of population-based reference intervals (RI) was determined appropriate only for PFA-CADP (index of individuality = 10.7). There was poor correlation between most platelet function tests. Use of population-based RI appears inappropriate for most platelet function tests, and tests poorly correlate with one another. Future studies on biologic variability and correlation of platelet function tests should be performed in dogs with platelet dysfunction and those treated with antiplatelet therapy. © 2015 American Society for Veterinary Clinical Pathology.

  8. Testing the Granger noncausality hypothesis in stationary nonlinear models of unknown functional form

    DEFF Research Database (Denmark)

    Péguin-Feissolle, Anne; Strikholm, Birgit; Teräsvirta, Timo

    In this paper we propose a general method for testing the Granger noncausality hypothesis in stationary nonlinear models of unknown functional form. These tests are based on a Taylor expansion of the nonlinear model around a given point in the sample space. We study the performance of our tests b...

  9. Conceptual design and testing strategy of a dual functional lithium-lead test blanket module in ITER and EAST

    International Nuclear Information System (INIS)

    Wu, Y.

    2007-01-01

    A dual functional lithium-lead (DFLL) test blanket module (TBM) concept has been proposed for testing in the International Thermonuclear Experimental Reactor (ITER) and the Experimental Advanced Superconducting Tokamak (EAST) in China to demonstrate the technologies of the liquid lithium-lead breeder blankets with emphasis on the balance between the risks and the potential attractiveness of blanket technology development. The design of DFLL-TBM concept has the flexibility of testing both the helium-cooled quasi-static lithium-lead (SLL) blanket concept and the He/PbLi dual-cooled lithium-lead (DLL) blanket concept. This paper presents an effective testing strategy proposed to achieve the testing target of SLL and DLL DEMO blankets relevant conditions, which includes three parts: materials R and D and small-scale out-of-pile mockups testing in loops, middle-scale TBMs pre-testing in EAST and full-scale consecutive TBMs testing corresponding to different operation phases of ITER during the first 10 years. The design of the DFLL-TBM concept and the testing strategy ability to test TBMs for both blanket concepts in sequence and or in parallel for both ITER and EAST are discussed

  10. 'There's a letter called ef' on Challenges and Repair in Interpreter-Mediated Tests of Cognitive Functioning in Dementia Evaluations

    DEFF Research Database (Denmark)

    Plejert, Charlotta; Antelius, Eleonor; Yazdanpanah, Maziar

    2015-01-01

    with memory problems and other dementia symptoms are referred for examination and evaluation. Very many elderly people with a foreign background require the assistance of an interpreter in their encounter with health-care facilities. The use of, and work by an interpreter is crucial in facilitating a smooth......In the Scandinavian countries Sweden, Denmark, Norway, and Finland, the number of first generation migrants reaching an old age, who will be in need of age-related health-care, is rapidly increasing. This situation poses new demands on health-care facilities, such as memory clinics, where patients...... the test of cognitive functioning. Special attention will be paid to the phenomenon 'repair', i.e., participants' joint attempts to solve upcoming difficulties during the course of interaction. Results show that sources of trouble may be related to the lack of cultural, linguistic, and educational...

  11. OBSERVER RATING VERSUS THREE-DIMENSIONAL MOTION ANALYSIS OF LOWER EXTREMITY KINEMATICS DURING FUNCTIONAL SCREENING TESTS: A SYSTEMATIC REVIEW.

    Science.gov (United States)

    Maclachlan, Liam; White, Steven G; Reid, Duncan

    2015-08-01

    the results of those assessing running and side-step cutting manoeuvres. Variables such as the speed of movement, the methods of rating, the profiles of participants and the experience levels of observers may have influenced the outcomes of functional testing. The small number of studies used limits generalizability. Furthermore, this review used two dimensional video-playback for the majority of observations. If the movements had been rated in real-time three dimensional video, the results may have been different. Slower, speed controlled movements using dichotomous ratings reach target sensitivity and demonstrate higher overall levels of agreement. As a result, their utilization in functional screening is advocated. 1A.

  12. Liver function test with 99mTc-labelled bilirubin in children

    International Nuclear Information System (INIS)

    Teichmann, B.; Kaempfer, I.; Schneider, G.

    1989-01-01

    Because of central role of bilirubin in the metabolism of liver it is well suited for liver function tests. Different parameters of hepatocellular partial function and histological findings were studied in patients suffering from functional hyperbilirubinaemia (n = 15), liver cirrhosis (n = 7) and 6 patients recovering from acute hepatitis. After intravenous injection of 99m Tc-bilirubin blood clearance and intestinal excretion in percentages of bilirubin were determined. In patients with cirrhosis the initial phase as well as the intestinal excretion of bilirubin were delayed. This liver function test is useful in the pediatric special diagnosis for investigations during the course of the illness and for assessment of therapeutic activities. (author)

  13. Functional cerebral lateralization and dual-task efficiency-testing the function of human brain lateralization using fTCD

    NARCIS (Netherlands)

    Lust, J. M.; Geuze, R. H.; Groothuis, A. G. G.; Bouma, A.; Bouma, J.M.

    2011-01-01

    It has been hypothesized that functional cerebral lateralization enhances cognitive performance. Evidence was found in birds and fish. Our study aimed to test this hypothesis by analyzing the relationship between cerebral lateralization and both single-task performance and dual-task efficiency in

  14. Luminosity performance reach after LS1

    International Nuclear Information System (INIS)

    Herr, W.

    2012-01-01

    Based on past experience (2010/2011), in particular expected limitations from beam-beam effects, and taking into account the expected beam quality from the LHC injectors, the peak and integrated luminosity at top energy is discussed for different scenarios (e.g. bunch spacing, beta*). In particular it will be shown which are the key parameters to reach the nominal luminosity and it is also shown that peak luminosities two times larger than nominal (or higher) are possible. Possible test in 2012 are discussed

  15. Distributed analysis functional testing using GangaRobot in the ATLAS experiment

    Science.gov (United States)

    Legger, Federica; ATLAS Collaboration

    2011-12-01

    Automated distributed analysis tests are necessary to ensure smooth operations of the ATLAS grid resources. The HammerCloud framework allows for easy definition, submission and monitoring of grid test applications. Both functional and stress test applications can be defined in HammerCloud. Stress tests are large-scale tests meant to verify the behaviour of sites under heavy load. Functional tests are light user applications running at each site with high frequency, to ensure that the site functionalities are available at all times. Success or failure rates of these tests jobs are individually monitored. Test definitions and results are stored in a database and made available to users and site administrators through a web interface. In this work we present the recent developments of the GangaRobot framework. GangaRobot monitors the outcome of functional tests, creates a blacklist of sites failing the tests, and exports the results to the ATLAS Site Status Board (SSB) and to the Service Availability Monitor (SAM), providing on the one hand a fast way to identify systematic or temporary site failures, and on the other hand allowing for an effective distribution of the work load on the available resources.

  16. Functional Task Test: 3. Skeletal Muscle Performance Adaptations to Space Flight

    Science.gov (United States)

    Ryder, Jeffrey W.; Wickwire, P. J.; Buxton, R. E.; Bloomberg, J. J.; Ploutz-Snyder, L.

    2011-01-01

    The functional task test is a multi-disciplinary study investigating how space-flight induced changes to physiological systems impacts functional task performance. Impairment of neuromuscular function would be expected to negatively affect functional performance of crewmembers following exposure to microgravity. This presentation reports the results for muscle performance testing in crewmembers. Functional task performance will be presented in the abstract "Functional Task Test 1: sensory motor adaptations associated with postflight alternations in astronaut functional task performance." METHODS: Muscle performance measures were obtained in crewmembers before and after short-duration space flight aboard the Space Shuttle and long-duration International Space Station (ISS) missions. The battery of muscle performance tests included leg press and bench press measures of isometric force, isotonic power and total work. Knee extension was used for the measurement of central activation and maximal isometric force. Upper and lower body force steadiness control were measured on the bench press and knee extension machine, respectively. Tests were implemented 60 and 30 days before launch, on landing day (Shuttle crew only), and 6, 10 and 30 days after landing. Seven Space Shuttle crew and four ISS crew have completed the muscle performance testing to date. RESULTS: Preliminary results for Space Shuttle crew reveal significant reductions in the leg press performance metrics of maximal isometric force, power and total work on R+0 (pperformance metrics were observed in returning Shuttle crew and these adaptations are likely contributors to impaired functional tasks that are ambulatory in nature (See abstract Functional Task Test: 1). Interestingly, no significant changes in central activation capacity were detected. Therefore, impairments in muscle function in response to short-duration space flight are likely myocellular rather than neuromotor in nature.

  17. Olefins and chemical regulation in Europe: REACH.

    Science.gov (United States)

    Penman, Mike; Banton, Marcy; Erler, Steffen; Moore, Nigel; Semmler, Klaus

    2015-11-05

    REACH (Registration, Evaluation, Authorisation and Restriction of Chemicals) is the European Union's chemical regulation for the management of risk to human health and the environment (European Chemicals Agency, 2006). This regulation entered into force in June 2007 and required manufacturers and importers to register substances produced in annual quantities of 1000 tonnes or more by December 2010, with further deadlines for lower tonnages in 2013 and 2018. Depending on the type of registration, required information included the substance's identification, the hazards of the substance, the potential exposure arising from the manufacture or import, the identified uses of the substance, and the operational conditions and risk management measures applied or recommended to downstream users. Among the content developed to support this information were Derived No-Effect Levels or Derived Minimal Effect Levels (DNELs/DMELs) for human health hazard assessment, Predicted No Effect Concentrations (PNECs) for environmental hazard assessment, and exposure scenarios for exposure and risk assessment. Once registered, substances may undergo evaluation by the European Chemicals Agency (ECHA) or Member State authorities and be subject to requests for additional information or testing as well as additional risk reduction measures. To manage the REACH registration and related activities for the European olefins and aromatics industry, the Lower Olefins and Aromatics REACH Consortium was formed in 2008 with administrative and technical support provided by Penman Consulting. A total of 135 substances are managed by this group including 26 individual chemical registrations (e.g. benzene, 1,3-butadiene) and 13 categories consisting of 5-26 substances. This presentation will describe the content of selected registrations prepared for 2010 in addition to the significant post-2010 activities. Beyond REACH, content of the registrations may also be relevant to other European activities, for

  18. Performance Comparison of Student-Athletes and General College Students on the Functional Movement Screen and the Y Balance Test.

    Science.gov (United States)

    Engquist, Katherine D; Smith, Craig A; Chimera, Nicole J; Warren, Meghan

    2015-08-01

    Although various studies have assessed performance of athletes on the Functional Movement Screen (FMS) and the Y Balance Test (YBT), no study to date has directly evaluated a comparison of performance between athletes and members of the general population. Thus, to better understand the application of the FMS and the YBT to general college students, this study examined whether or not general college students performed similarly to student-athletes on the FMS (composite and movement pattern scores) and the YBT (composite and reach directions). This study evaluated 167 Division I student-athletes and 103 general college students from the same university on the FMS and the YBT. No difference was found in FMS composite scores between student-athletes and general college students. For FMS movement patterns, female student-athletes scored higher than general college students in the deep squat. No difference was found for men in any FMS movement pattern. Female student-athletes scored higher than female general college students in YBT composite scores; no difference was found for men in YBT composite scores. In analysis of YBT reach directions, female student-athletes scored higher than female general college students in all reach directions, whereas no difference was found in men. Existing research on the FMS composite score in athletic populations may apply to a general college population for the purposes of preparticipation screening, injury prediction, etc. Existing research on the YBT in male athletic populations is expected to apply equally to general college males for the purposes of preparticipation screening, injury prediction, etc.

  19. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    Science.gov (United States)

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  20. Reaching for the red planet

    Science.gov (United States)

    David, L

    1996-05-01

    The distant shores of Mars were reached by numerous U.S. and Russian spacecraft throughout the 1960s to mid 1970s. Nearly 20 years have passed since those successful missions which orbited and landed on the Martian surface. Two Soviet probes headed for the planet in July, 1988, but later failed. In August 1993, the U.S. Mars Observer suddenly went silent just three days before it was to enter orbit around the planet and was never heard from again. In late 1996, there will be renewed activity on the launch pads with three probes departing for the red planet: 1) The U.S. Mars Global Surveyor will be launched in November on a Delta II rocket and will orbit the planet for global mapping purposes; 2) Russia's Mars '96 mission, scheduled to fly in November on a Proton launcher, consists of an orbiter, two small stations which will land on the Martian surface, and two penetrators that will plow into the terrain; and finally, 3) a U.S. Discovery-class spacecraft, the Mars Pathfinder, has a December launch date atop a Delta II booster. The mission features a lander and a microrover that will travel short distances over Martian territory. These missions usher in a new phase of Mars exploration, setting the stage for an unprecedented volley of spacecraft that will orbit around, land on, drive across, and perhaps fly at low altitudes over the planet.

  1. Metasurface holograms reaching 80% efficiency.

    Science.gov (United States)

    Zheng, Guoxing; Mühlenbernd, Holger; Kenney, Mitchell; Li, Guixin; Zentgraf, Thomas; Zhang, Shuang

    2015-04-01

    Surfaces covered by ultrathin plasmonic structures--so-called metasurfaces--have recently been shown to be capable of completely controlling the phase of light, representing a new paradigm for the design of innovative optical elements such as ultrathin flat lenses, directional couplers for surface plasmon polaritons and wave plate vortex beam generation. Among the various types of metasurfaces, geometric metasurfaces, which consist of an array of plasmonic nanorods with spatially varying orientations, have shown superior phase control due to the geometric nature of their phase profile. Metasurfaces have recently been used to make computer-generated holograms, but the hologram efficiency remained too low at visible wavelengths for practical purposes. Here, we report the design and realization of a geometric metasurface hologram reaching diffraction efficiencies of 80% at 825 nm and a broad bandwidth between 630 nm and 1,050 nm. The 16-level-phase computer-generated hologram demonstrated here combines the advantages of a geometric metasurface for the superior control of the phase profile and of reflectarrays for achieving high polarization conversion efficiency. Specifically, the design of the hologram integrates a ground metal plane with a geometric metasurface that enhances the conversion efficiency between the two circular polarization states, leading to high diffraction efficiency without complicating the fabrication process. Because of these advantages, our strategy could be viable for various practical holographic applications.

  2. An Association Between Functional Polymorphisms of the Interleukin 1 Gene Complex and Schizophrenia Using Transmission Disequilibrium Test.

    Science.gov (United States)

    Kapelski, Pawel; Skibinska, Maria; Maciukiewicz, Malgorzata; Pawlak, Joanna; Dmitrzak-Weglarz, Monika; Szczepankiewicz, Aleksandra; Zaremba, Dorota; Twarowska-Hauser, Joanna

    2016-12-01

    IL1 gene complex has been implicated in the etiology of schizophrenia. To assess whether IL1 gene complex is associated with susceptibility to schizophrenia in Polish population we conducted family-based study. Functional polymorphisms from IL1A (rs1800587, rs17561, rs11677416), IL1B (rs1143634, rs1143643, rs16944, rs4848306, rs1143623, rs1143633, rs1143627) and IL1RN (rs419598, rs315952, rs9005, rs4251961) genes were genotyped in 143 trio with schizophrenia. Statistical analysis was performed using transmission disequilibrium test. We have found a trend toward an association of rs1143627, rs16944, rs1143623 in IL1B gene with the risk of schizophrenia. Our results show a protective effect of allele T of rs4251961 in IL1RN against schizophrenia. We also performed haplotype analysis of IL1 gene complex and found a trend toward an association with schizophrenia of GAGG haplotype (rs1143627, rs16944, rs1143623, rs4848306) in IL1B gene, haplotypes: TG (rs315952, rs9005) and TT (rs4251961, rs419598) in IL1RN. Haplotype CT (rs4251961, rs419598) in IL1RN was found to be associated with schizophrenia. After correction for multiple testing associations did not reach significance level. Our results might support theory that polymorphisms of interleukin 1 complex genes (rs1143627, rs16944, rs1143623, rs4848306 in IL1B gene and rs4251961, rs419598, rs315952, rs9005 in IL1RN gene) are involved in the pathogenesis of schizophrenia, however, none of the results reach significance level after correction for multiple testing.

  3. A criterion for testing hypotheses about the covariance function of a stationary Gaussian stochastic process

    OpenAIRE

    Kozachenko, Yuriy; Troshki, Viktor

    2015-01-01

    We consider a measurable stationary Gaussian stochastic process. A criterion for testing hypotheses about the covariance function of such a process using estimates for its norm in the space $L_p(\\mathbb {T}),\\,p\\geq1$, is constructed.

  4. Applications of majorization and Schur functions in reliability and life testing

    International Nuclear Information System (INIS)

    Proschan, F.

    1975-01-01

    This is an expository paper presenting basic definitions and properties of majorization and Schur functions, and displaying a variety of applications of these concepts in reliability prediction and modelling, and in reliability inference and life testing

  5. Assessment of respiratory involvement in children with mucoplysaccharidosis using pulmonary function tests

    Directory of Open Access Journals (Sweden)

    Mona M. El Falaki

    2014-01-01

    Conclusions: Evaluation and follow up of patients with MPS using pulmonary function tests are essential to detect early involvement of respiratory system and hence start treatment for respiratory complications early in the course of the disease.

  6. Reaching with the sixth sense

    DEFF Research Database (Denmark)

    Reichenbach, Alexandra; Bresciani, Jean-Pierre; Bulthoff, Heinrich H.

    2016-01-01

    The vestibular system constitutes the silent sixth sense: It automatically triggers a variety of vital reflexes to maintain postural and visual stability. Beyond their role in reflexive behavior, vestibular afferents contribute to several perceptual and cognitive functions and also support volunt...

  7. A new tool for investigating the functional testing of the VOR

    Directory of Open Access Journals (Sweden)

    Paolo eColagiorgio

    2013-10-01

    Full Text Available Peripheral vestibular function may be tested quantitatively, by measuring the gain of the angular vestibulo-ocular reflex (aVOR, or functionally, by assessing how well the aVOR performs with respect to its goal of stabilizing gaze in space and thus allow to acquire visual information during the head movement. In recent years, several groups have developed clinical and quantitative approaches to functional testing of the vestibular system based on the ability to identify an optotype briefly displayed on screen during head rotations.Although the proposed techniques differ in terms of the parameters controlling the testing paradigm, no study has thus far dealt with understanding the role of such choices in determining the effectiveness and reliability of the testing approach. Moreover, recent work has shown that peripheral vestibular patients may produce corrective saccades during the head movement (covert saccades, yet the role of these eye movements towards reading ability during head rotations is not yet understood. Finally, no study has thus far dealt with measuring the true performance of their experimental setups, which is nonetheless likely to be crucial information for understanding the effectiveness of functional testing approaches. Thus we propose a new software and hardware research tool allowing the combined measurement of eye and head movements, together with the timing of the optotype on screen, during functional testing of the VOR based on the Head Impulse Test (HIT. The goal of such tool is therefore that of allowing functional testing of the VOR while collecting the experimental data necessary to understand, for instance, a the effectiveness of the covert saccades strategy towards image stabilization, b which experimental parameters are crucial for optimizing the diagnostic power of the functional testing approach, and c which conditions lead to a successful reading or an error trial.

  8. A Modified Reading the Mind in the Eyes Test Predicts Behavioral Variant Frontotemporal Dementia Better Than Executive Function Tests

    Directory of Open Access Journals (Sweden)

    Matthias L. Schroeter

    2018-01-01

    Full Text Available Behavioral variant frontotemporal dementia (bvFTD is characterized by deep alterations in behavior and personality. Although revised diagnostic criteria agree for executive dysfunction as most characteristic, impairments in social cognition are also suggested. The study aimed at identifying those neuropsychological and behavioral parameters best discriminating between bvFTD and healthy controls. Eighty six patients were diagnosed with possible or probable bvFTD according to Rascovsky et al. (2011 and compared with 43 healthy age-matched controls. Neuropsychological performance was assessed with a modified Reading the Mind in the Eyes Test (RMET, Stroop task, Trail Making Test (TMT, Hamasch-Five-Point Test (H5PT, and semantic and phonemic verbal fluency tasks. Behavior was assessed with the Apathy Evaluation Scale, Frontal Systems Behavioral Scale, and Bayer Activities of Daily Living Scale. Each test’s discriminatory power was investigated by Receiver Operating Characteristic curves calculating the area under the curve (AUC. bvFTD patients performed significantly worse than healthy controls in all neuropsychological tests. Discriminatory power (AUC was highest in behavioral questionnaires, high in verbal fluency tasks and the RMET, and lower in executive function tests such as the Stroop task, TMT and H5PT. As fluency tasks depend on several cognitive functions, not only executive functions, results suggest that the RMET discriminated better between bvFTD and control subjects than other executive tests. Social cognition should be incorporated into diagnostic criteria for bvFTD in the future, such as in the International Classification of Diseases (ICD-11, as already suggested in the Diagnostic and Statistical Manual for Mental Disorders (DSM-5.

  9. Safety and Function Test Report for the Viryd CS8 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Roadman, J.; Murphy, M.; van Dam, J.

    2013-10-01

    This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. Several turbines were selected for testing at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) as a part of the Small Wind Turbine Independent Testing project. Safety and function testing is one of up to five tests that may be performed on the turbines. Other tests include duration, power performance, acoustic noise, and power quality. Viryd Technologies, Inc. of Austin, Texas, was the recipient of the DOE grant and provided the turbine for testing.

  10. Executive Functions as Endophenotypes in ADHD: Evidence from the Cambridge Neuropsychological Test Battery (CANTAB)

    Science.gov (United States)

    Gau, Susan Shur-Fen; Shang, Chi-Yung

    2010-01-01

    Background: Little is known about executive functions among unaffected siblings of children with attention deficit/hyperactivity disorder (ADHD), and there is lack of such information from non-Western countries. We examined verbal and nonverbal executive functions in adolescents with ADHD, unaffected siblings and controls to test whether executive…

  11. THE MAKE BREAK TEST AS A DIAGNOSTIC-TOOL IN FUNCTIONAL WEAKNESS

    NARCIS (Netherlands)

    VANDERPLOEG, RJO; OOSTERHUIS, HJGH

    Strength was measured in four major muscle groups with a hand-held dynamometer. The "make" and "break" technique was used with and without encouragement, and fatiguability was tested in patients with organic weakness and patients with functional weakness. Patients with functional weakness could be

  12. Testing a parametric function against a nonparametric alternative in IV and GMM settings

    DEFF Research Database (Denmark)

    Gørgens, Tue; Wurtz, Allan

    This paper develops a specification test for functional form for models identified by moment restrictions, including IV and GMM settings. The general framework is one where the moment restrictions are specified as functions of data, a finite-dimensional parameter vector, and a nonparametric real ...

  13. Validity of the German Version of the Continuous-Scale Physical Functional Performance 10 Test

    Directory of Open Access Journals (Sweden)

    Irene Härdi

    2017-01-01

    Full Text Available Background. The Continuous-Scale Physical Functional Performance 10 Test (CS-PFP 10 quantitatively assesses physical functional performance in older adults who have a broad range of physical functional ability. This study assessed the validity and reliability of the CS-PFP 10 German version. Methods. Forward-translations and backtranslations as well as cultural adaptions of the test were conducted. Participants were German-speaking Swiss community-dwelling adults aged 64 and older. Concurrent validity was assessed using Pearson correlation coefficients between CS-PFP 10 and gait velocity, Timed Up and Go Test, hand grip strength, SF-36 physical function domain, and Freiburger Physical Activity Questionnaire. Internal consistency was calculated by Cronbach’s alpha. Results. Backtranslation and cultural adaptions were accepted by the CS-PFP 10 developer. CS-PFP 10 total score and subscores (upper body strength, upper body flexibility, lower body strength, balance and coordination, and endurance correlated significantly with all measures of physical function tested. Internal consistency was high (Cronbach’s alpha 0.95–0.98. Conclusion. The CS-PFP 10 German version is valid and reliable for measuring physical functional performance in German-speaking Swiss community-dwelling older adults. Quantifying physical function is essential for clinical practice and research and provides meaningful insight into physical functional performance of older adults. This trial is registered with ClinicalTrials.gov NCT01539200.

  14. Influence of functional knee bracing on the isokinetic and functional tests of anterior cruciate ligament deficient patients.

    Directory of Open Access Journals (Sweden)

    Niyousha Mortaza

    Full Text Available Use of functional knee braces has been suggested to provide protection and to improve kinetic performance of the knee in Anterior cruciate ligament(ACL-injured patients. However, many athletes might refrain from wearing the braces because of the fear of performance hindrance in the playing field. The aim of this study was to examine the effect of three functional knee brace/sleeves upon the isokinetic and functional performance of ACL-deficient and healthy subjects. Six anterior cruciate ligament deficient (29.0 ± 5.3 yrs., 175.2 ± 5.4 cm, and 73.0 ± 10.0 kg and six healthy male subjects (27.2 ± 3.7 yrs., 176.4 ± 6.4 cm, and 70.3 ± 6.9 kg were selected. The effect of a custom-made functional knee brace, and two neoprene knee sleeves, one with four metal supports and one without support were examined via the use of isokinetic and functional tests in four sets (non-braced,wearing functional knee brace,and wearing the sleeves. Cross-over hop and single leg vertical jump test were performed and jump height, and hop distance were recorded. Peak torque to body weight ratio and average power in two isokinetic velocities(60°.s(-1,180°.s(-1 were recorded and the brace/sleeves effect was calculated as the changes in peak torque measured in the brace/sleeves conditions, expressed as a percentage of peak torque measured in non-braced condition. Frequency content of the isokinetic torque-time curves was also analyzed. Wilcoxon signed rank test was used to compare the measured values in four test conditions within each control and ACL-deficient group,and Mann-Whitney U test was used for the comparison between the two groups. No significant differences in peak torque, average power, torque-time curve frequency content, vertical-jump and hop measurements were found within the experimental and the non-braced conditions (p>0.05. Although the examined functional knee brace/sleeves had no significant effect on the knee muscle performance, there have been

  15. Reliability of candida skin test in the evaluation of T-cell function in ...

    African Journals Online (AJOL)

    Background: Both standardized and non-standardized candida skin tests are used in clinical practice for functional in-vivo assessment of cellular immunity with variable results and are considered not reliable under the age of 1 year. We sought to investigate the reliability of using manually prepared candida intradermal test ...

  16. Fracture-mechanical results of non-destructive testing - function, goals, methods

    International Nuclear Information System (INIS)

    Herter, K.H.; Kockelmann, H.; Schuler, X.; Waidele, H.

    2004-01-01

    Non-destructive testing provides data for fracture-mechanical analyses, e.g. defect size and orientation. On the other hand, fracture-mechanical analyses may help to define criteria for non-destructive testing, e.g. sensitivity, inspection intervals and inspection sites. The criteria applied differ as a function of the safety relevance of a component. (orig.) [de

  17. Application of functional IDDQ testing in a VLIW processor towards detection of aging degradation

    NARCIS (Netherlands)

    Kerkhoff, Hans G.; Zhao, Yong

    2015-01-01

    In this paper, functional IDDQ testing has been applied for a 90nm VLIW processor to effectively detect aging degradation. This technique can provide health data for reliability evaluation as used in e.g. prognostic software for lifetime prediction. The test environment for validation, implementing

  18. Functional Capacity Evaluation in Upper Limb Reduction Deficiency and Amputation : Development and Pilot Testing

    NARCIS (Netherlands)

    Postema, S G; Bongers, R M; Reneman, M F; van der Sluis, C K

    Purpose To develop and pilot test a functional capacity evaluation (FCE) for individuals with upper limb absence (ULA) due to reduction deficiency or amputation, and to examine the relationship between FCE results and presence of musculoskeletal complaints (MSC). Method Five tests (overhead lifting,

  19. Unit-based functional IDDT testing for aging degradation monitoring in a VLIW processor

    NARCIS (Netherlands)

    Zhao, Yong; Kerkhoff, Hans G.

    2015-01-01

    In this paper, functional unit-based IDDT testing has been applied for a 90nm VLIW processor to monitor its aging degradation. This technique can provide health data for reliability evaluation as used in e.g. prognostic software for lifetime prediction. The test-program development based on the

  20. Power and Sample Size Calculations for Logistic Regression Tests for Differential Item Functioning

    Science.gov (United States)

    Li, Zhushan

    2014-01-01

    Logistic regression is a popular method for detecting uniform and nonuniform differential item functioning (DIF) effects. Theoretical formulas for the power and sample size calculations are derived for likelihood ratio tests and Wald tests based on the asymptotic distribution of the maximum likelihood estimators for the logistic regression model.…

  1. Wind Turbine Generator System Safety and Function Test Report for the Entegrity EW50 Wind Turbine

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J.; Huskey, A.; Jager, D.; Hur, J.

    2012-11-01

    This report summarizes the results of a safety and function test that NREL conducted on the Entegrity EW50 wind turbine. This test was conducted in accordance with the International Electrotechnical Commissions' (IEC) standard, Wind Turbine Generator System Part 2: Design requirements for small wind turbines, IEC 61400-2 Ed.2.0, 2006-03.

  2. Test-retest reliability of the isernhagen work systems functional capacity evaluation in healthy adults

    NARCIS (Netherlands)

    Reneman, MF; Brouwer, S; Meinema, A; Dijkstra, PU; Geertzen, JHB; Groothoff, JW

    2004-01-01

    Aim of this study was to investigate test-retest reliability of the Isernhagen Work System Functional Capacity Evaluation (IWS FCE) in healthy subjects. The IWS FCE consists of 28 tests that reflect work-related activities such as lifting, carrying, bending, etc. A convenience sample of 26 healthy

  3. EPRI instruments reach commercial market

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The Electric Power Research Institute has developed instruments capable of verifying time responses of power plant pressure sensors and temperature sensors. A patent is pending on the pressure-sensor device, and the temperature-sensor device is already commercially available. The devices, EPRI's first hardware products to be marketed, are the result of research to find technological solutions to the problems of knowing the time period when temperature and pressure changes occur in light water reactors. The hydraulic pressure-sensor device is a portable unit that can conveniently test equipment in place. Utilities can obtain detailed information from EPRI's project report to construct their own. The loop current step response (LCSR), measuring resistance temperature, is also a compact system suitable for in-plant testing

  4. Seismic functional qualification of active mechanical and electrical component based on shaking table testing

    International Nuclear Information System (INIS)

    Jurukovski, D.; Mamucevski, D.

    1996-01-01

    This report involves the description of the experimental seismic and vibration tests of electrical, mechanical and processing equipment that were carried out by using laboratory equipment with high performances. This equipment should generate programmable dynamic excitations, measure and analyze parameters defining dynamic behaviour of the structural and functional capabilities of the tested specimen. Development of testing methodology and criteria is described together with the method for processing the results. Application of the methodology and criteria to selected specimen is included

  5. Cold Pump Test and Training and Mock-Up Facility Functions and Requirements

    International Nuclear Information System (INIS)

    BELLOMY, J.R.

    2000-01-01

    This document defines the functions and requirements (F and R) for a test facility to provide for pre-deployment, checkout, testing, and training for the underground storage tank retrieval equipment, systems, and crews that will be developed or deployed as part of Waste Feed Delivery. The F and R for a River Protection Project retrieval test facility, one that supports a production mode tank farm system, are identified

  6. GRAN SASSO: Reaching the parts that accelerators cannot reach

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    With most of the current experiments at Italy's Gran Sasso Laboratory now well underway, a workshop held earlier this year looked to the future. Gran Sasso was established in the late 1980s to study low rate processes where the laboratory's 1400 metre rock overburden and low natural radioactivity provide an ideal environment. Since then, it has become a major research centre, hosting several international collaborations. The workshop devoted half a day each to four key areas of underground physics, and clearly showed how the non-accelerator approach complements today's accelerator physics achievements. Solar neutrino physics is one of Gran Sasso's main activities, with the Gallex detector half filling one of the laboratory's three experimental halls. Gallex has already made important measurements of the solar neutrino flux, providing first evidence for the proton-proton fusion mechanism which is the solar powerhouse. The next generation experiment, Borexino, will go one step further, measuring the energy distribution of solar neutrinos as well as their flux. The experiment will also be sensitive to neutrino oscillations through its ability to pick out muon and tau neutrinos. Borexino uses boron instead of gallium as the active medium, and is currently in the trial phase. Benchmarking tests with the counter test facility (CTF) have already demonstrated the experiment's feasibility, paving the way for full scale construction. Further ideas for future detectors based on several different active media were also discussed, and a proposal for a helium TPC detector, HELLAZ, was presented. With a threshold of around 240 keV, comparable to that of Gallex and Borexino, HELLAZ would give another handle on neutrinos from the proton-proton reaction, the most abundant source of solar neutrinos. Neutrinoless double beta decay, dark matter searches, and certain low rate processes in nuclear physics all require the quiet, low radiation surroundings

  7. Limits of clinical tests to screen autonomic function in diabetes type 1.

    Science.gov (United States)

    Ducher, M; Bertram, D; Sagnol, I; Cerutti, C; Thivolet, C; Fauvel, J P

    2001-11-01

    A precocious detection of cardiac autonomic dysfunction is of major clinical interest that could lead to a more intensive supervision of diabetic patients. However, classical clinical exploration of cardiac autonomic function is not easy to undertake in a reproducible way. Thus, respective interests of autonomic nervous parameters provided by both clinical tests and computerized analysis of resting blood pressure were checked in type 1 diabetic patients without orthostatic hypotension and microalbuminuria. Thirteen diabetic subjects matched for age and gender to thirteen healthy subjects volunteered to participate to the study. From clinical tests (standing up, deep breathing, Valsalva maneuver, handgrip test), autonomic function was scored according to Ewing's methodology. Analysis of resting beat to beat blood pressure provided autonomic indices of the cardiac function (spectral analysis or Z analysis). 5 of the 13 diabetic patients exhibited a pathological score (more than one pathological response) suggesting the presence of cardiovascular autonomic dysfunction. The most discriminative test was the deep breathing test. However, spectral indices of BP recordings and baro-reflex sensitivity (BRS) of these 5 subjects were similar to those of healthy subjects and of remaining diabetic subjects. Alteration in Ewing's score given by clinical tests may not reflect an alteration of cardiac autonomic function in asymptomatic type 1 diabetic patients, because spectral indices of sympathetic and parasympathetic (including BRS) function were within normal range. Our results strongly suggest to confront results provided by both methodologies before concluding to an autonomic cardiac impairment in asymptomatic diabetic patients.

  8. The Application of Normal Stress Reduction Function in Tilt Tests for Different Block Shapes

    Science.gov (United States)

    Kim, Dong Hyun; Gratchev, Ivan; Hein, Maw; Balasubramaniam, Arumugam

    2016-08-01

    This paper focuses on the influence of the shapes of rock cores, which control the sliding or toppling behaviours in tilt tests for the estimation of rock joint roughness coefficients (JRC). When the JRC values are estimated by performing tilt tests, the values are directly proportional to the basic friction of the rock material and the applied normal stress on the sliding planes. Normal stress obviously varies with the shape of the sliding block, and the basic friction angle is also affected by the sample shapes in tilt tests. In this study, the shapes of core blocks are classified into three representative shapes and those are created using plaster. Using the various shaped artificial cores, a set of tilt tests is carried out to identify the shape influences on the normal stress and the basic friction angle in tilt tests. The test results propose a normal stress reduction function to estimate the normal stress for tilt tests according to the sample shapes based on Barton's empirical equation. The proposed normal stress reduction functions are verified by tilt tests using artificial plaster joints and real rock joint sets. The plaster joint sets are well matched and cast in detailed printed moulds using a 3D printing technique. With the application of the functions, the obtained JRC values from the tilt tests using the plaster samples and the natural rock samples are distributed within a reasonable JRC range when compared with the measured values.

  9. Intrinsic motivation, neurocognition and psychosocial functioning in schizophrenia: testing mediator and moderator effects.

    Science.gov (United States)

    Nakagami, Eri; Xie, Bin; Hoe, Maanse; Brekke, John S

    2008-10-01

    This study examined the nature of the relationships among neurocognition, intrinsic motivation, and psychosocial functioning for persons with schizophrenia. Hypotheses concerning both mediator and moderator mechanisms were tested. 120 individuals diagnosed with schizophrenia were recruited as they entered outpatient psychosocial rehabilitation programs. Measures of psychosocial functioning and intrinsic motivation were administered at baseline. Measures of neurocognition were administered at baseline by testers blind to scores on other study variables. Data were analyzed using latent construct modeling to test for mediator and moderator effects. There were strong bivariate relationships between neurocognition, intrinsic motivation, and psychosocial functioning. The results demonstrated that intrinsic motivation strongly mediated the relationship between neurocognition and psychosocial functioning. This mediation was evidenced by: (i) the direct path from neurocognition to functional outcome no longer being statistically significant after the introduction of motivation into the model, (ii) the statistical significance of the indirect path from neurocognition through motivation to functional outcome. There was no support for the two moderation hypotheses: the level of neurocognition did not influence the relationship between intrinsic motivation and psychosocial functioning, nor did the level of intrinsic motivation influence the relationship between neurocognition and psychosocial functioning. Neurocognition influences psychosocial functioning through its relationship with intrinsic motivation. Intrinsic motivation is a critical mechanism for explaining the relationship between neurocognition and psychosocial functioning. Implications for the theoretical understanding and psychosocial treatment of intrinsic motivation in schizophrenia are discussed.

  10. Riparian Vegetation Mapping Along the Hanford Reach

    International Nuclear Information System (INIS)

    FOGWELL, T.W.

    2003-01-01

    During the biological survey and inventory of the Hanford Site conducted in the mid-1990s (1995 and 1996), preliminary surveys of the riparian vegetation were conducted along the Hanford Reach. These preliminary data were reported to The Nature Conservancy (TNC), but were not included in any TNC reports to DOE or stakeholders. During the latter part of FY2001, PNNL contracted with SEE Botanical, the parties that performed the original surveys in the mid 1990s, to complete the data summaries and mapping associated with the earlier survey data. Those data sets were delivered to PNNL and the riparian mapping by vegetation type for the Hanford Reach is being digitized during the first quarter of FY2002. These mapping efforts provide the information necessary to create subsequent spatial data layers to describe the riparian zone according to plant functional types (trees, shrubs, grasses, sedges, forbs). Quantification of the riparian zone by vegetation types is important to a number of DOE'S priority issues including modeling contaminant transport and uptake in the near-riverine environment and the determination of ecological risk. This work included the identification of vegetative zones along the Reach by changes in dominant plant species covering the shoreline from just to the north of the 300 Area to China Bar near Vernita. Dominant and indicator species included Agropyron dasytachyudA. smithii, Apocynum cannabinum, Aristida longiseta, Artemisia campestris ssp. borealis var scouleriana, Artemisa dracunculus, Artemisia lindleyana, Artemisia tridentata, Bromus tectorum, Chrysothamnus nauseosus, Coreopsis atkinsoniana. Eleocharis palustris, Elymus cinereus, Equisetum hyemale, Eriogonum compositum, Juniperus trichocarpa, Phalaris arundinacea, Poa compressa. Salk exigua, Scirpus acutus, Solidago occidentalis, Sporobolus asper,and Sporobolus cryptandrus. This letter report documents the data received, the processing by PNNL staff, and additional data gathered in FY2002

  11. Objective effect manifestation of pectus excavatum on load-stressed pulmonary function testing: a case report

    Directory of Open Access Journals (Sweden)

    Chan Jason

    2011-12-01

    Full Text Available Abstract Introduction Pectus excavatum is the most common congenital deformity of the anterior chest wall that, under certain conditions, may pose functional problems due to cardiopulmonary compromise and exercise intolerance. Case presentation We present the case of an otherwise physically-adept 21-year-old Chinese sportsman with idiopathic pectus excavatum, whose symptoms manifested only on bearing a loaded body vest and backpack during physical exercise. Corroborative objective evidence was obtained via load-stressed pulmonary function testing, which demonstrated restrictive lung function. Conclusion This report highlights the possible detrimental synergism of thoracic load stress and pectus excavatum on cardiopulmonary function. Thoracic load-stressed pulmonary function testing provides objective evidence in support of such a synergistic relationship.

  12. Interactions of heart disease and lung disease on radionuclide tests of lung anatomy and function

    International Nuclear Information System (INIS)

    Pierson, R.N. Jr.; Barrett, C.R. Jr.; Yamashina, A.; Friedman, M.I.

    1984-01-01

    This paper considers the effects of heat diseases on lung anatomy, lung function, and pulmonary nuclear test procedures, and also the effects of lung diseases on cardiac function, with particular reference to radionuclide tests. Historically, pulmonary nuclear medicine has been focused on discovering and quantifying pulmonary embolism, but the potential of nuclear tracer techniques to carry out high-precision, regional, quantitative measurements of blood flow, air flow, and membrane transport promises a much more powerful and wide-ranging diagnostic application than the search for pulmonary emboli. The authors therefore define normal anatomy and function in a framework suitable to develop the relationships between cardiac and pulmonary function, with particular attention to regional differences in lung function, since regional measurements provide a special province for radionuclide lung studies

  13. Modification of Harvard step-test for assessment of students’ with health problems functional potentials

    Directory of Open Access Journals (Sweden)

    E.N. Kopeikina

    2016-08-01

    Full Text Available Purpose: to substantiate, work out and experimentally prove modified test for assessment of students’ with health problems functional potentials. Material: in the research students and girl students of 18-20 years’ age (n=522 participated. According to the worked out modification of test during 30 seconds student ascended on bench (h=43 cm and descended from it. Then pulse was measured three times. In total the test took 4 minutes. Results: For working out the scale for interpretation of the received results we assessed new 30 seconds’ modification of Harvard step-test for validity. First, for this purpose all students fulfilled modified step-test. Then after full restoration (after 20 minutes they fulfilled its three minutes’ variant. Correlation analysis of the received results showed the presence of average correlation between two samples (r=0.64. Conclusions: application of this modified variant permits for pedagogues to completely assess functional potentials of students with heath problems.

  14. Have Standard Tests of Cognitive Function Been Misappropriated in the Study of Cognitive Enhancement?

    Directory of Open Access Journals (Sweden)

    Iseult A. Cremen

    2017-05-01

    Full Text Available In the past decade, there has emerged a vast research literature dealing with attempts to harness brain plasticity in older adults, with a view to improving cognitive function. Since cognitive training (CT has shown restricted utility in this regard, attention has increasingly turned to interventions that use adjunct procedures such as motor training or physical activity (PA. As evidence builds that these have some efficacy, it becomes necessary to ensure that the outcome measures being used to infer causal influence upon cognitive function are subjected to appropriate critical appraisal. It has been highlighted previously that the choice of specific tasks used to demonstrate transfer to the cognitive domain is of critical importance. In the context of most intervention studies, standardized tests and batteries of cognitive function are de rigueur. The argument presented here is that the latent constructs to which these tests relate are not usually subject to a sufficient level of analytic scrutiny. We present the historical origins of some exemplar tests, and give particular consideration to the limits on explanatory scope that are implied by their composition and the nature of their deployment. In addition to surveying the validity of these tests when used to appraise intervention-related changes in cognitive function, we also consider their neurophysiological correlates. In particular, we argue that the broadly distributed brain activity associated with the performance of many tests of cognitive function, extending to the classical motor networks, permits the impact of interventions based on motor training or PA to be better understood.

  15. Test-retest and interrater reliability of the functional lower extremity evaluation.

    Science.gov (United States)

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  16. The relationship between neuropsychological tests of visuospatial function and lobar cortical thickness.

    Science.gov (United States)

    Zink, Davor N; Miller, Justin B; Caldwell, Jessica Z K; Bird, Christopher; Banks, Sarah J

    2018-06-01

    Tests of visuospatial function are often administered in comprehensive neuropsychological evaluations. These tests are generally considered assays of parietal lobe function; however, the neural correlates of these tests, using modern imaging techniques, are not well understood. In the current study we investigated the relationship between three commonly used tests of visuospatial function and lobar cortical thickness in each hemisphere. Data from 374 patients who underwent a neuropsychological evaluation and MRI scans in an outpatient dementia clinic were included in the analysis. We examined the relationships between cortical thickness, as assessed with Freesurfer, and performance on three tests: Judgment of Line Orientation (JoLO), Block Design (BD) from the Fourth edition of the Wechsler Adult Intelligence Scale, and Brief Visuospatial Memory Test-Revised Copy Trial (BVMT-R-C) in patients who showed overall average performance on these tasks. Using a series of multiple regression models, we assessed which lobe's overall cortical thickness best predicted test performance. Among the individual lobes, JoLO performance was best predicted by cortical thickness in the right temporal lobe. BD performance was best predicted by cortical thickness in the right parietal lobe, and BVMT-R-C performance was best predicted by cortical thickness in the left parietal lobe. Performance on constructional tests of visuospatial function appears to correspond best with underlying cortical thickness of the parietal lobes, while performance on visuospatial judgment tests appears to correspond best to temporal lobe thickness. Future research using voxel-wise and connectivity techniques and including more diverse samples will help further understanding of the regions and networks involved in visuospatial tests.

  17. Switching from reaching to navigation: differential cognitive strategies for spatial memory in children and adults.

    Science.gov (United States)

    Belmonti, Vittorio; Cioni, Giovanni; Berthoz, Alain

    2015-07-01

    Navigational and reaching spaces are known to involve different cognitive strategies and brain networks, whose development in humans is still debated. In fact, high-level spatial processing, including allocentric location encoding, is already available to very young children, but navigational strategies are not mature until late childhood. The Magic Carpet (MC) is a new electronic device translating the traditional Corsi Block-tapping Test (CBT) to navigational space. In this study, the MC and the CBT were used to assess spatial memory for navigation and for reaching, respectively. Our hypothesis was that school-age children would not treat MC stimuli as navigational paths, assimilating them to reaching sequences. Ninety-one healthy children aged 6 to 11 years and 18 adults were enrolled. Overall short-term memory performance (span) on both tests, effects of sequence geometry, and error patterns according to a new classification were studied. Span increased with age on both tests, but relatively more in navigational than in reaching space, particularly in males. Sequence geometry specifically influenced navigation, not reaching. The number of body rotations along the path affected MC performance in children more than in adults, and in women more than in men. Error patterns indicated that navigational sequences were increasingly retained as global paths across development, in contrast to separately stored reaching locations. A sequence of spatial locations can be coded as a navigational path only if a cognitive switch from a reaching mode to a navigation mode occurs. This implies the integration of egocentric and allocentric reference frames, of visual and idiothetic cues, and access to long-term memory. This switch is not yet fulfilled at school age due to immature executive functions. © 2014 John Wiley & Sons Ltd.

  18. The pharmacists' role in improving guideline compliance for thyroid function testing in patients with heart failure.

    Science.gov (United States)

    Ziman, Melanie E; Bui, Hien T; Smith, Craig S; Tsukiji, Lori A; Asmatey, Veda M; Chu, Steven B; Miano, John S

    2012-04-01

    This single-center retrospective pilot program's objective was to utilize outpatient pharmacists to improve laboratory test adherence in chronic heart failure (CHF) patients overdue for thyroid function testing, thereby demonstrating the value of the outpatient pharmacist and justifying possible clinical role expansion. Thyroid disorders may contribute to CHF development, progression, and exacerbation. Testing is the standard of care in CHF patients per American Heart Association's 2009 Guidelines. Delinquency was defined as labs not conducted within 1 year in patients with euthyroid history, within 6 months in patients with thyroid dysfunction, abnormal labs at any time without follow-up, or lab absence after thyroid medication initiation, adjustment, or discontinuation. Targeted 80 nonpregnant adult CHF patients with delinquent thyroid function tests were counseled to get thyroid labs at point of sale, via telephone, e-mail, or letter. In collaboration with physicians, pharmacists ordered thyroid-stimulating hormone (TSH) and free T4 (FT4) labs. For patients with abnormal laboratory results, pharmacists coordinated drug therapy and follow-up labs. Data were collected from November 1, 2009 to March 30, 2010. Seventy-two patients (90%) previously delinquent for thyroid function testing received relevant thyroid labs. Ten patients (12.5%) with abnormal thyroid function tests not on prior drug therapy received treatment.

  19. Five times sit-to-stand test in subjects with total knee replacement: Reliability and relationship with functional mobility tests.

    Science.gov (United States)

    Medina-Mirapeix, Francesc; Vivo-Fernández, Iván; López-Cañizares, Juan; García-Vidal, José A; Benítez-Martínez, Josep Carles; Del Baño-Aledo, María Elena

    2018-01-01

    The objective was to determine the inter-observer and test/retest reliability of the "Five-repetition sit-to-stand" (5STS) test in patients with total knee replacement (TKR). To explore correlation between 5STS and two mobility tests. A reliability study was conducted among 24 (mean age 72.13, S.D. 10.67; 50% were women) outpatients with TKR. They were recruited from a traumatology unit of a public hospital via convenience sampling. A physiotherapist and trauma physician assessed each patient at the same time. The same physiotherapist realized a 5STS second measurement 45-60min after the first one. Reliability was assessed with intraclass correlation coefficients (ICCs) and Bland-Altman plots. Pearson coefficient was calculated to assess the correlation between 5STS, time up to go test (TUG) and four meters gait speed (4MGS). ICC for inter-observer and test-retest reliability of the 5STS were 0.998 (95% confidence interval [CI], 0.995-0.999) and 0.982 (95% CI, 0.959-0.992). Bland-Altman plot inter-observer showed limits between -0.82 and 1.06 with a mean of 0.11 and no heteroscedasticity within the data. Bland-Altman plot for test-retest showed the limits between 1.76 and 4.16, a mean of 1.20 and heteroscedasticity within the data. Pearson correlation coefficient revealed significant correlation between 5STS and TUG (r=0.7, ptest-retest reliability when it is used in people with TKR, and also significant correlation with other functional mobility tests. These findings support the use of 5STS as outcome measure in TKR population. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Intra-operative Assessment of the Spinal Cord Function: Awakening Compared to Ankle Clonus Test

    International Nuclear Information System (INIS)

    Amin, Wafik A.; Tealab, Ayman I.; Ei-Gendy, Eslah H.; Esmat, Hesham A.

    2006-01-01

    The spinal cord is at high risk of injury during special procedures such as correction of scoliosis. Recovery from impairement is directly proportional to the time of removal of the instrumentations. For this, methods used to detect the neurologic injury should be continuous, fast, sensitive and specific. The present study was performed to evaluate the ankle clonus as a test for the integrity of the spinal cord function intraoperatively. Twenty eight scoliotic patients were included in the study. The ankle clonus was tested before, during and after the correction and fixation followed by the wake-up test to correlate the results of both rests. The haemodynamics changes at the time of the two tests were compared. It was found out that, the ankle clonus test correlated well with the wake-up test, with only two false positive results. No false negative results were recorded which was an important finding. The haemodynamic changes were better during the ankle clonus test than during the wake-up test. It was concluded that the ankle clonus test is reliable, safe, and faster than the wake-up test. It is recommended to use the test to evaluate the integrity of the spinal cord during the operations with potential risk to the cord. In case the result of the ankle clonus is positive, the wake-up test should be done before an attempt to release or remove the instrumentations. (author)

  1. Work-related measures of physical and behavioral health function: Test-retest reliability.

    Science.gov (United States)

    Marino, Molly Elizabeth; Meterko, Mark; Marfeo, Elizabeth E; McDonough, Christine M; Jette, Alan M; Ni, Pengsheng; Bogusz, Kara; Rasch, Elizabeth K; Brandt, Diane E; Chan, Leighton

    2015-10-01

    The Work Disability Functional Assessment Battery (WD-FAB), developed for potential use by the US Social Security Administration to assess work-related function, currently consists of five multi-item scales assessing physical function and four multi-item scales assessing behavioral health function; the WD-FAB scales are administered as Computerized Adaptive Tests (CATs). The goal of this study was to evaluate the test-retest reliability of the WD-FAB Physical Function and Behavioral Health CATs. We administered the WD-FAB scales twice, 7-10 days apart, to a sample of 376 working age adults and 316 adults with work-disability. Intraclass correlation coefficients were calculated to measure the consistency of the scores between the two administrations. Standard error of measurement (SEM) and minimal detectable change (MDC90) were also calculated to measure the scales precision and sensitivity. For the Physical Function CAT scales, the ICCs ranged from 0.76 to 0.89 in the working age adult sample, and 0.77-0.86 in the sample of adults with work-disability. ICCs for the Behavioral Health CAT scales ranged from 0.66 to 0.70 in the working age adult sample, and 0.77-0.80 in the adults with work-disability. The SEM ranged from 3.25 to 4.55 for the Physical Function scales and 5.27-6.97 for the Behavioral Health function scales. For all scales in both samples, the MDC90 ranged from 7.58 to 16.27. Both the Physical Function and Behavioral Health CATs of the WD-FAB demonstrated good test-retest reliability in adults with work-disability and general adult samples, a critical requirement for assessing work related functioning in disability applicants and in other contexts. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. A simple behavioral test for locomotor function after brain injury in mice.

    Science.gov (United States)

    Tabuse, Masanao; Yaguchi, Masae; Ohta, Shigeki; Kawase, Takeshi; Toda, Masahiro

    2010-11-01

    To establish a simple and reliable test for assessing locomotor function in mice with brain injury, we developed a new method, the rotarod slip test, in which the number of slips of the paralytic hind limb from a rotarod is counted. Brain injuries of different severity were created in adult C57BL/6 mice, by inflicting 1-point, 2-point and 4-point cryo-injuries. These mice were subjected to the rotarod slip test, the accelerating rotarod test and the elevated body swing test (EBST). Histological analyses were performed to assess the severity of the brain damage. Significant and consistent correlations between test scores and severity were observed for the rotarod slip test and the EBST. Only the rotarod slip test detected the mild hindlimb paresis in the acute and sub-acute phase after injury. Our results suggest that the rotarod slip test is the most sensitive and reliable method for assessing locomotor function after brain damage in mice. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Operational Reach: Is Current Army Doctrine Adequate?

    National Research Council Canada - National Science Library

    Heintzelman, Scott

    2003-01-01

    The term operational reach, an element of operational design, is new to U.S. Army doctrine. Operational reach is not found in the previous edition of the Army's basic operational doctrine, Field Manual...

  4. Stream Habitat Reach Summary - NCWAP [ds158

    Data.gov (United States)

    California Natural Resource Agency — The Stream Habitat - NCWAP - Reach Summary [ds158] shapefile contains in-stream habitat survey data summarized to the stream reach level. It is a derivative of the...

  5. Robot-assisted reaching exercise promotes arm movement recovery in chronic hemiparetic stroke: a randomized controlled pilot study

    Directory of Open Access Journals (Sweden)

    Rymer W Zev

    2006-06-01

    Full Text Available Abstract Background and purpose Providing active assistance to complete desired arm movements is a common technique in upper extremity rehabilitation after stroke. Such active assistance may improve recovery by affecting somatosensory input, motor planning, spasticity or soft tissue properties, but it is labor intensive and has not been validated in controlled trials. The purpose of this study was to investigate the effects of robotically administered active-assistive exercise and compare those with free reaching voluntary exercise in improving arm movement ability after chronic stroke. Methods Nineteen individuals at least one year post-stroke were randomized into one of two groups. One group performed 24 sessions of active-assistive reaching exercise with a simple robotic device, while a second group performed a task-matched amount of unassisted reaching. The main outcome measures were range and speed of supported arm movement, range, straightness and smoothness of unsupported reaching, and the Rancho Los Amigos Functional Test of Upper Extremity Function. Results and discussion There were significant improvements with training for range of motion and velocity of supported reaching, straightness of unsupported reaching, and functional movement ability. These improvements were not significantly different between the two training groups. The group that performed unassisted reaching exercise improved the smoothness of their reaching movements more than the robot-assisted group. Conclusion Improvements with both forms of exercise confirmed that repeated, task-related voluntary activation of the damaged motor system is a key stimulus to motor recovery following chronic stroke. Robotically assisting in reaching successfully improved arm movement ability, although it did not provide any detectable, additional value beyond the movement practice that occurred concurrently with it. The inability to detect any additional value of robot-assisted reaching

  6. Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Shahrbano Shahbazi

    2013-12-01

    Full Text Available Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG. Methods: In 146 patients scheduled for on-pump CABG, the liver function test was done preoperatively and on the first postoperative day. Some preoperative and intraoperative risk factors were checked and then the postoperative liver function tests were compared with the preoperative ones. Probable relationships between these changes and the preoperative and intraoperative risk factors were studied. Results: A medical history of diabetes had a significant relationship with the changes in direct bilirubin. Preoperative central venous pressure had a significant relationship with the changes in aspartate aminotransferase and alanine aminotransferase. Use of intra-aortic balloon pump and duration of aortic cross-clamp were significantly related to the changes in the liver function tests except for alanine aminotransferase and alkaline phosphatase. Conclusion: It seems that the techniques for the reduction of cardiopulmonary bypass and aortic cross-clamp duration may be useful to protect liver function. We recommend that a larger population of patients be studied to confirm these findings.

  7. The Evaluation of Pulmonary Function Tests in Patients with Polycystic Ovary Syndrome

    Directory of Open Access Journals (Sweden)

    Mahdis Maraashi

    2013-10-01

    Full Text Available Introduction: Recently a relation between female sex hormones and severity of asthma symptoms has been proposed. As a common endocrine dysfunction, polycystic ovary syndrome (PCOS could significantly influence the level of sex hormones in PCOS patients. Regarding the possible role of sex hormones in airway physiology, the present study was conducted to survey the effects of PCOS on pulmonary function test parameters. Materials and Methods: In this cross-sectional study 30 recently diagnosed patients with PCOS without history of pulmonary disease were enrolled and 20 healthy women were considered as the control group according to their age, weight, and height. The patients and the controls underwent body plethysmography to measure pulmonary function tests. Results: The mean age of the patients and the controls were 29.43±7.8 and 30.0±7.6 years respectively. There were no statistically significant differences in all pulmonary function test parameters between the patients and the controls (p>0.05. After dividing the patients into 2 groups based on their body mass index (BMI, BMIConclusion: Our results showed that pulmonary function test parameters are not different in PCOS patients comparing to healthy women. Only the deleterious effects of high BMI on pulmonary function can be occurred in these patients.

  8. Abnormal Liver Function Tests in an Anorexia Nervosa Patient and an Atypical Manifestation of Refeeding Syndrome

    Directory of Open Access Journals (Sweden)

    Vamshidhar R. Vootla

    2015-07-01

    Full Text Available Refeeding syndrome is defined as electrolyte and fluid abnormalities that occur in significantly malnourished patients when they are refed orally, enterally, or parenterally. The principal manifestations include hypophosphatemia, hypokalemia, vitamin deficiencies, volume overload and edema. This can affect multiple organ systems, such as the cardiovascular, pulmonary, or neurological systems, secondary to the above-mentioned abnormalities. Rarely, patients may develop gastrointestinal symptoms and show abnormal liver function test results. We report the case of a 52-year-old woman with anorexia nervosa who developed refeeding syndrome and simultaneous elevations of liver function test results, which normalized upon the resolution of the refeeding syndrome.

  9. Abnormal Liver Function Tests in an Anorexia Nervosa Patient and an Atypical Manifestation of Refeeding Syndrome.

    Science.gov (United States)

    Vootla, Vamshidhar R; Daniel, Myrta

    2015-01-01

    Refeeding syndrome is defined as electrolyte and fluid abnormalities that occur in significantly malnourished patients when they are refed orally, enterally, or parenterally. The principal manifestations include hypophosphatemia, hypokalemia, vitamin deficiencies, volume overload and edema. This can affect multiple organ systems, such as the cardiovascular, pulmonary, or neurological systems, secondary to the above-mentioned abnormalities. Rarely, patients may develop gastrointestinal symptoms and show abnormal liver function test results. We report the case of a 52-year-old woman with anorexia nervosa who developed refeeding syndrome and simultaneous elevations of liver function test results, which normalized upon the resolution of the refeeding syndrome.

  10. The diagnostic effects of s-TSH and TRH stimulating test on subclinical thyroid function

    International Nuclear Information System (INIS)

    Lu Shujun; Wang Wenliang; Lu Shuyan; Zheng Linong; Hu Changjun; Fang Xiaozheng; Zheng Huian; Ma Meizhen

    2002-01-01

    The study was carried out to investigate the diagnostic effects of supersensitive TSH on diagnosing subclinical thyroid function with only once s-TSH detection and with TRH stimulating tests. TRH stimulating tests have been undertaken for 90 patients with different thyroid disease and 58 normal subjects. Diagnostic basal levels of s-TSH test in control group, subclinical hyperthyroidism group and subclinical hypothyroidism group were 2.20 +- 1.85 mIU/L, 0.54 +- 0.3 mIU/L and 9.08 +- 6.3 mIU/L, respectively, the levels of subclinical hyperthyroidism and subclinical hypothyroidism group were significantly higher than that of normal subjects group (P s -TSH>30 mIU/L. Dynamic observing of TRH stimulating tests have more effect than that of only once s-TSH detection in diagnosing subclinical thyroid function

  11. Improving ATLAS grid site reliability with functional tests using HammerCloud

    CERN Document Server

    Legger, F; The ATLAS collaboration

    2012-01-01

    With the exponential growth of LHC (Large Hadron Collider) data in 2011, and more coming in 2012, distributed computing has become the established way to analyse collider data. The ATLAS grid infrastructure includes almost 100 sites worldwide, ranging from large national computing centers to smaller university clusters. These facilities are used for data reconstruction and simulation, which are centrally managed by the ATLAS production system, and for distributed user analysis. To ensure the smooth operation of such a complex system, regular tests of all sites are necessary to validate the site capability of successfully executing user and production jobs. We report on the development, optimization and results of an automated functional testing suite using the HammerCloud framework. Functional tests are short light-weight applications covering typical user analysis and production schemes, which are periodically submitted to all ATLAS grid sites. Results from those tests are collected and used to evaluate site...

  12. Improving ATLAS grid site reliability with functional tests using HammerCloud

    CERN Document Server

    Legger, F; The ATLAS collaboration; Medrano Llamas, R; Sciacca, G; Van der Ster, D C

    2012-01-01

    With the exponential growth of LHC (Large Hadron Collider) data in 2011, and more coming in 2012, distributed computing has become the established way to analyse collider data. The ATLAS grid infrastructure includes more than 80 sites worldwide, ranging from large national computing centers to smaller university clusters. These facilities are used for data reconstruction and simulation, which are centrally managed by the ATLAS production system, and for distributed user analysis. To ensure the smooth operation of such a complex system, regular tests of all sites are necessary to validate the site capability of successfully executing user and production jobs. We report on the development, optimization and results of an automated functional testing suite using the HammerCloud framework. Functional tests are short light-weight applications covering typical user analysis and production schemes, which are periodically submitted to all ATLAS grid sites. Results from those tests are collected and used to evaluate si...

  13. Barrier function test: Laboratory evaluation of the protective function of some barrier creams against cashewnut shell oil

    Directory of Open Access Journals (Sweden)

    Pasricha J

    1991-01-01

    Full Text Available A barrier function test has been designed to screen the protective capacity of a cream against the cauterizing effect of cashew nut shell oil (CNSO on the skin. The test consists of applying the barrier cream on a 5 cm circular area of skin on the back of a human volunteer and then at its centre applying a 1 cm sq Whatman no. 3 paper disc soaked in the CNSO for 15 minutes and looking for the evidence of cauterization reaction after 48 hours. Of the various creams containing a variety of paraffins, bees wax, polyethylene glycols, methyl cellulose gel, and petrolatum, only polyethylene glycol (PEG cream was found to afford adequate protection against cashew nut shell oil. Addition of 10% zinc oxide or 10% kaolin to the PEG cream did not seem to afford any additional protection. Castor oil already being used by the workers was found to be inferior to the PEG cream.

  14. Tc-99m DTPA renal function tests and diuretic renogram in the dilated upper urinary tract

    Energy Technology Data Exchange (ETDEWEB)

    Sakagami, Yoshinari; Yamaguchi, Osamu; Suzuki, Takayuki; Kameoka, Hiroshi; Shiraiwa, Yasuo; Suzuki, Akira (Fukushima Medical Coll. (Japan))

    1992-09-01

    The authors studied patients with dilated upper urinary tracts (16 patients) using radioisotopic split renal function tests and diuretic renogram with [sup 99]mTc-diethylenetriaminepentaacetic acid (Tc-99m DTPA). The etiology was ureteropelvic function stenosis, 11; primary megaureter, 3; ureteral stenosis, 1; and aberrant vessel, 1. Response to diuresis was classified into 3 groups: i.e., obstructive pattern, non-obstructive pattern and partial obstructive pattern. In the non-obstructive group, split renal function was good, and thus an operation was not indicated. In the obstructive group, split renal function was significantly decreased and these patients underwent surgery. In the partial obstructive group, if function of the obstructed kidney was approximately the same as that of the non-obstructed side, then surgery was considered unnecessary. (author).

  15. Tc-99m DTPA renal function tests and diuretic renogram in the dilated upper urinary tract

    International Nuclear Information System (INIS)

    Sakagami, Yoshinari; Yamaguchi, Osamu; Suzuki, Takayuki; Kameoka, Hiroshi; Shiraiwa, Yasuo; Suzuki, Akira

    1992-01-01

    The authors studied patients with dilated upper urinary tracts (16 patients) using radioisotopic split renal function tests and diuretic renogram with 99 mTc-diethylenetriaminepentaacetic acid (Tc-99m DTPA). The etiology was ureteropelvic function stenosis, 11; primary megaureter, 3; ureteral stenosis, 1; and aberrant vessel, 1. Response to diuresis was classified into 3 groups: i.e., obstructive pattern, non-obstructive pattern and partial obstructive pattern. In the non-obstructive group, split renal function was good, and thus an operation was not indicated. In the obstructive group, split renal function was significantly decreased and these patients underwent surgery. In the partial obstructive group, if function of the obstructed kidney was approximately the same as that of the non-obstructed side, then surgery was considered unnecessary. (author)

  16. Decreased prefrontal functional brain response during memory testing in women with Cushing's syndrome in remission.

    Science.gov (United States)

    Ragnarsson, Oskar; Stomby, Andreas; Dahlqvist, Per; Evang, Johan A; Ryberg, Mats; Olsson, Tommy; Bollerslev, Jens; Nyberg, Lars; Johannsson, Gudmundur

    2017-08-01

    Neurocognitive dysfunction is an important feature of Cushing's syndrome (CS). Our hypothesis was that patients with CS in remission have decreased functional brain responses in the prefrontal cortex and hippocampus during memory testing. In this cross-sectional study we included 19 women previously treated for CS and 19 controls matched for age, gender, and education. The median remission time was 7 (IQR 6-10) years. Brain activity was studied with functional magnetic resonance imaging during episodic- and working-memory tasks. The primary regions of interest were the prefrontal cortex and the hippocampus. A voxel-wise comparison of functional brain responses in patients and controls was performed. During episodic-memory encoding, patients displayed lower functional brain responses in the left and right prefrontal gyrus (pright inferior occipital gyrus (pbrain responses in the left posterior hippocampus in patients (p=0.05). During episodic-memory retrieval, the patients displayed lower functional brain responses in several brain areas with the most predominant difference in the right prefrontal cortex (pbrain response during a more complex working memory task compared with a simpler one. In conclusion, women with CS in long-term remission have reduced functional brain responses during episodic and working memory testing. This observation extends previous findings showing long-term adverse effects of severe hypercortisolaemia on brain function. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Muscular exercise can cause highly pathological liver function tests in healthy men.

    Science.gov (United States)

    Pettersson, Jonas; Hindorf, Ulf; Persson, Paula; Bengtsson, Thomas; Malmqvist, Ulf; Werkström, Viktoria; Ekelund, Mats

    2008-02-01

    The occurrence of idiosyncratic drug hepatotoxicity is a major problem in all phases of clinical drug development and the leading cause of postmarketing warnings and withdrawals. Physical exercise can result in transient elevations of liver function tests. There is no consensus in the literature on which forms of exercise may cause changes in liver function tests and to what extent. Weightlifting results in profound increases in liver function tests in healthy men used to moderate physical activity, not including weightlifting. Liver function tests are significantly increased for at least 7 days after weightlifting. It is important to impose relevant restrictions on heavy muscular exercise prior to and during clinical studies. To investigate the effect of intensive muscular exercise (weightlifting) on clinical chemistry parameters reflecting liver function in healthy men. Fifteen healthy men, used to moderate physical activity not including weightlifting, performed an 1 h long weightlifting programme. Blood was sampled for clinical chemistry parameters [aspartate aminotransferase (AST), alanine aminotransferase (ALT), lactate dehydrogenase (LD), gamma-glutamyl transferase (gamma GT), alkaline phosphatase (ALP), bilirubin, creatine kinase (CK) and myoglobin] at repeated intervals during 7 days postexercise and at a follow-up examination 10-12 days postexercise. Five out of eight studied clinical chemistry parameters (AST, ALT, LD, CK and myoglobin) increased significantly after exercise (P exercise. In addition, LD and, in particular, CK and myoglobin showed highly elevated levels. These findings highlight the importance of imposing restrictions on weightlifting prior to and during clinical studies. Intensive muscular exercise, e.g. weightlifting, should also be considered as a cause of asymptomatic elevations of liver function tests in daily clinical practice.

  18. Clinical usefulness of dual-label Schilling test for pancreatic exocrine function

    Energy Technology Data Exchange (ETDEWEB)

    Chen, W.L.; Morishita, R.; Eguchi, T.; Kawai, T.; Sakai, M.; Tateishi, H.; Uchino, H.

    1989-05-01

    The usefulness of the pancreatic dual-label Schilling test as an indirect test of pancreatic exocrine function was evaluated. This dual-label Schilling test was based on the difference of absorption for (58Co)cobalamin bound to hog R protein and (57Co)cobalamin bound to intrinsic factor. In this study, the test was performed in 7 normal subjects, 5 patients with pancreatectomy, 12 patients with chronic pancreatitis, 10 patients with suspicion of chronic pancreatitis, and 13 patients without chronic pancreatitis. The normal lower limit (mean -2 SD) of excretion ratio for (58Co)/(57Co) in 24-h urine was 0.68. Of the 26 patients on whom endoscopic retrograde pancreatography was performed, none of the 9 patients with normal pancreatogram, 4 of the 9 patients with mild to moderate pancreatitic changes in pancreatogram, and 7 of the 8 patients with advanced pancreatitic changes in pancreatogram showed a positive value lower than the ratio of 0.68 in this test. In 28 patients examined with the direct test of pancreatic secretory capacity, 2 of the 13 patients with normal function, 6 of the 9 patients with mild dysfunction, and 5 of the 6 patients with definite dysfunction were positive in this test. The results of the pancreatic dual-label Schilling test significantly correlated with those of a direct test of pancreatic secretory capacity and the findings of pancreatitic changes in pancreatogram (p less than 0.01, chi 2 test). The ratio for (58Co)/(57Co) correlated (r = 0.73) with the maximal bicarbonate concentration in duodenal juice of the direct test of pancreatic secretory capacity. The impairment of bicarbonate output by the pancreas may adversely affect the transfer of cobalamin from R protein to intrinsic factor.

  19. Clinical usefulness of dual-label Schilling test for pancreatic exocrine function

    International Nuclear Information System (INIS)

    Chen, W.L.; Morishita, R.; Eguchi, T.; Kawai, T.; Sakai, M.; Tateishi, H.; Uchino, H.

    1989-01-01

    The usefulness of the pancreatic dual-label Schilling test as an indirect test of pancreatic exocrine function was evaluated. This dual-label Schilling test was based on the difference of absorption for [58Co]cobalamin bound to hog R protein and [57Co]cobalamin bound to intrinsic factor. In this study, the test was performed in 7 normal subjects, 5 patients with pancreatectomy, 12 patients with chronic pancreatitis, 10 patients with suspicion of chronic pancreatitis, and 13 patients without chronic pancreatitis. The normal lower limit (mean -2 SD) of excretion ratio for [58Co]/[57Co] in 24-h urine was 0.68. Of the 26 patients on whom endoscopic retrograde pancreatography was performed, none of the 9 patients with normal pancreatogram, 4 of the 9 patients with mild to moderate pancreatitic changes in pancreatogram, and 7 of the 8 patients with advanced pancreatitic changes in pancreatogram showed a positive value lower than the ratio of 0.68 in this test. In 28 patients examined with the direct test of pancreatic secretory capacity, 2 of the 13 patients with normal function, 6 of the 9 patients with mild dysfunction, and 5 of the 6 patients with definite dysfunction were positive in this test. The results of the pancreatic dual-label Schilling test significantly correlated with those of a direct test of pancreatic secretory capacity and the findings of pancreatitic changes in pancreatogram (p less than 0.01, chi 2 test). The ratio for [58Co]/[57Co] correlated (r = 0.73) with the maximal bicarbonate concentration in duodenal juice of the direct test of pancreatic secretory capacity. The impairment of bicarbonate output by the pancreas may adversely affect the transfer of cobalamin from R protein to intrinsic factor

  20. Multi-Function Waste Tank Facility Corrosion Test Report (Phase 1)

    International Nuclear Information System (INIS)

    Carlos, W. C.; Fritz, R. L.

    1993-01-01

    This report documents the results of the corrosion tests that were performed to aid in the selection of the construction materials for multi-function waste tanks to be built in the U.S. Department of Energy Hanford Site. Two alloys were tested: 304L and Alloy 20 austenitic stainless steel. The test media were aqueous solutions formulated to represent the extreme of the chemical compositions of waste to be stored in the tanks. The results summerized by alloy are as follows: For 304L the tests showed no stress-corrosion cracking in any of the nine test solutions. The tests showed pitting in on of the solutions. There were no indications of any weld heat-tint corrosion, nor any sign of preferential corrosion in the welded areas. For Alloy 20 the tests showed no general, pitting, or stress-corrosion cracking. One crevice corrosion coupon cracked at the web between a hole and the edge of the coupon in one of the solutions. Mechanical tests showed some possible crack extension in the same solution. Because of the failure of both alloys to meet test acceptance criteria, the tank waste chemistry will have to be restricted or an alternative alloy tested

  1. Standardised test protocol (Constant Score) for evaluation of functionality in patients with shoulder disorders

    DEFF Research Database (Denmark)

    Ban, Ilija; Troelsen, Anders; Christiansen, David Høyrup

    2013-01-01

    INTRODUCTION: The Constant Score (CS), developed as a scoring system to evaluate overall functionality of patients with shoulder disorders, is widely used but has been criticised for relying on an imprecise terminology and for lack of a standardised methodology. A modified guideline was therefore...... differences. One of the authors of the modified CS approved both the English and the Danish test protocol. CONCLUSION: A simple test protocol of the modified CS was developed in both English and Danish. With precise terminology and definitions, the test protocol is the first of its kind. We suggest its use...

  2. [Progress in isokinetic technology in testing and training for assessment of muscle function].

    Science.gov (United States)

    Huang, Ting-Ting; Fan, Li-Hua; Gao, Dong; Xia, Qing; Zhang, Min

    2013-02-01

    Isokinetic technology in testing and training is the most advanced practical technique in the evaluation of muscle function. This method is a continuous dynamic test in the full range of the joint motion which has strong pertinence at the aspect of assessing muscle strength, and is an objective and quantitative method for reflecting each point's muscle strength in the range of the joint motion. This article reviews the key concepts, brief history of development and influencing factors of isokinetic technology in testing and training, introduces the progress in the field of rehabilitation medicine and sport science, etc., and discusses the future exploration in forensic science.

  3. Relationships of Functional Tests Following ACL Reconstruction: Exploratory Factor Analyses of the Lower Extremity Assessment Protocol.

    Science.gov (United States)

    DiFabio, Melissa; Slater, Lindsay V; Norte, Grant; Goetschius, John; Hart, Joseph M; Hertel, Jay

    2018-03-01

    After ACL reconstruction (ACLR), deficits are often assessed using a variety of functional tests, which can be time consuming. It is unknown whether these tests provide redundant or unique information. To explore relationships between components of a battery of functional tests, the Lower Extremity Assessment Protocol (LEAP) was created to aid in developing the most informative, concise battery of tests for evaluating ACLR patients. Descriptive, cross-sectional. Laboratory. 76 ACLR patients (6.86±3.07 months postoperative) and 54 healthy participants. Isokinetic knee flexion and extension at 90 and 180 degrees/second, maximal voluntary isometric contraction for knee extension and flexion, single leg balance, 4 hopping tasks (single, triple, crossover, and 6-meter timed hop), and a bilateral drop vertical jump that was scored with the Landing Error Scoring System (LESS). Peak torque, average torque, average power, total work, fatigue indices, center of pressure area and velocity, hop distance and time, and LESS score. A series of factor analyses were conducted to assess grouping of functional tests on the LEAP for each limb in the ACLR and healthy groups and limb symmetry indices (LSI) for both groups. Correlations were run between measures that loaded on retained factors. Isokinetic and isometric strength tests for knee flexion and extension, hopping, balance, and fatigue index were identified as unique factors for all limbs. The LESS score loaded with various factors across the different limbs. The healthy group LSI analysis produced more factors than the ACLR LSI analysis. Individual measures within each factor had moderate to strong correlations. Isokinetic and isometric strength, hopping, balance, and fatigue index provided unique information. Within each category of measures, not all tests may need to be included for a comprehensive functional assessment of ACLR patients due to the high amount of shared variance between them.

  4. Executive function assessment in patients with subcortical cerebral infarction using the Trail Making Test and Wisconsin Card Sorting Test

    International Nuclear Information System (INIS)

    Niiyama, Kazuhide; Hasegawa, Akira; Kato, Haruhisa; Umesato, Naoyuki; Utsumi, Hiroya

    2008-01-01

    To assess executive function in patients with subcortical cerebral infarctions, we implemented a Trail Making Test (TMT) and Wisconsin Card Sorting Test (WCST). We recruited 19 patients who had subcortical cerebral infarction on magnetic resonance images (MRI). The patients were classified into two categories depending on the degree of deep white matter hyperintensity (DWMH) on MRI. On comparing MRI and pathological findings, the punctate DWMH was not associated with infarction, but large confluent DWMH suggests subcortical ischemia. On this basis, the low grade DWMH group consisted of 12 patients with punctate foci, and seven patients with large confluent areas were classified in the high grade DWMH group. All patients were right-handed and without symptomatic hemiparesis. To exclude demented patients, cognitive function was examined. The vascular lesions were confirmed by brain magnetic resonance angiography and ultrasonography of the carotid arteries, and we excluded patients with severe stenotic or occlusive vascular lesions in cerebral or carotid arteries. On TMT, we analyzed the time required for Part A and Part B, and the difference in time required (required time difference). We also subtracted the time required for Part A form that required for Part B. To exclude the influence of potential hemiparesis, we also calculated the time required ratio expressed as follows; time required for Part B/time required for Part A. There was no significant increase in the time required for Part A, but we found significant increase in the time required for Part B, the required time difference and the required time ratio in the high grade DWMH group. There was no significant difference on WCST. On pathological examination in normal elderly subjects, punctate foci can be found, but not large confluent DWMH. In this study, we found that patients with severe DWMH may have impaired executive functions. These results might be induced by the pathological features of subcortical

  5. REACH: impact on the US cosmetics industry?

    Science.gov (United States)

    Pouillot, Anne; Polla, Barbara; Polla, Ada

    2009-03-01

    The Registration, Evaluation, Authorization and restriction of Chemicals (REACH) is a recent European regulation on chemical substances meant to protect human health and the environment. REACH imposes the "precautionary principle" where additional data and definitive action are required when uncertainty is identified. The cosmetics industry is only partially concerned by REACH: while the stages of registration and evaluation apply to cosmetics, those of authorization and restriction most likely will not, as cosmetic ingredients are already subject to regulation by various agencies and directives. REACH has potential benefits to the industry including the possibility of reassuring consumers and improving their image of chemicals and cosmetics. However, REACH also has potential disadvantages, mainly with regard to impeding innovation. The American cosmetics industry will be affected by REACH, because all US manufacturers who export substances to Europe will have to fully comply with REACH.

  6. Riparian Vegetation Mapping Along the Hanford Reach

    Energy Technology Data Exchange (ETDEWEB)

    FOGWELL, T.W.

    2003-07-11

    During the biological survey and inventory of the Hanford Site conducted in the mid-1990s (1995 and 1996), preliminary surveys of the riparian vegetation were conducted along the Hanford Reach. These preliminary data were reported to The Nature Conservancy (TNC), but were not included in any TNC reports to DOE or stakeholders. During the latter part of FY2001, PNNL contracted with SEE Botanical, the parties that performed the original surveys in the mid 1990s, to complete the data summaries and mapping associated with the earlier survey data. Those data sets were delivered to PNNL and the riparian mapping by vegetation type for the Hanford Reach is being digitized during the first quarter of FY2002. These mapping efforts provide the information necessary to create subsequent spatial data layers to describe the riparian zone according to plant functional types (trees, shrubs, grasses, sedges, forbs). Quantification of the riparian zone by vegetation types is important to a number of DOE'S priority issues including modeling contaminant transport and uptake in the near-riverine environment and the determination of ecological risk. This work included the identification of vegetative zones along the Reach by changes in dominant plant species covering the shoreline from just to the north of the 300 Area to China Bar near Vernita. Dominant and indicator species included Agropyron dasytachyudA. smithii, Apocynum cannabinum, Aristida longiseta, Artemisia campestris ssp. borealis var scouleriana, Artemisa dracunculus, Artemisia lindleyana, Artemisia tridentata, Bromus tectorum, Chrysothamnus nauseosus, Coreopsis atkinsoniana. Eleocharis palustris, Elymus cinereus, Equisetum hyemale, Eriogonum compositum, Juniperus trichocarpa, Phalaris arundinacea, Poa compressa. Salk exigua, Scirpus acutus, Solidago occidentalis, Sporobolus asper,and Sporobolus cryptandrus. This letter report documents the data received, the processing by PNNL staff, and additional data gathered in FY

  7. Gastroesophageal reflux symptoms are not sufficient to guide esophageal function testing in lung transplant candidates.

    Science.gov (United States)

    Posner, S; Zheng, J; Wood, R K; Shimpi, R A; Hartwig, M G; Chow, S-C; Leiman, D A

    2018-05-01

    Gastroesophageal reflux disease and esophageal dysmotility are prevalent in patients with advanced lung disease and are associated with graft dysfunction following lung transplantation. As a result, many transplant centers perform esophageal function testing as part of the wait-listing process but guidelines for testing in this population are lacking. The aim of this study is to describe whether symptoms of gastroesophageal reflux correlate with abnormal results on pH-metry and high-resolution manometry and can be used to identify those who require testing. We performed a retrospective cohort study of 226 lung transplant candidates referred for high-resolution manometry and pH-metry over a 12-month period in 2015. Demographic data, results of a standard symptom questionnaire and details of esophageal function testing were obtained. Associations between the presence of symptoms and test results were analyzed using Fisher's exact tests and multivariable logistic regression. The most common lung disease diagnosis was interstitial lung disease (N = 131, 58%). Abnormal pH-metry was seen in 116 (51%) patients and the presence of symptoms was significantly associated with an abnormal study (p advanced lung disease, symptoms of gastroesophageal reflux increase the likelihood of elevated acid exposure on pH-metry but were not associated with dysmotility. Given the proportion of asymptomatic patients with abnormal studies and associated post-transplant risks, a practice of universal high-resolution manometry and pH-metry testing in this population is justifiable.

  8. Machine Learning Approach for Software Reliability Growth Modeling with Infinite Testing Effort Function

    Directory of Open Access Journals (Sweden)

    Subburaj Ramasamy

    2017-01-01

    Full Text Available Reliability is one of the quantifiable software quality attributes. Software Reliability Growth Models (SRGMs are used to assess the reliability achieved at different times of testing. Traditional time-based SRGMs may not be accurate enough in all situations where test effort varies with time. To overcome this lacuna, test effort was used instead of time in SRGMs. In the past, finite test effort functions were proposed, which may not be realistic as, at infinite testing time, test effort will be infinite. Hence in this paper, we propose an infinite test effort function in conjunction with a classical Nonhomogeneous Poisson Process (NHPP model. We use Artificial Neural Network (ANN for training the proposed model with software failure data. Here it is possible to get a large set of weights for the same model to describe the past failure data equally well. We use machine learning approach to select the appropriate set of weights for the model which will describe both the past and the future data well. We compare the performance of the proposed model with existing model using practical software failure data sets. The proposed log-power TEF based SRGM describes all types of failure data equally well and also improves the accuracy of parameter estimation more than existing TEF and can be used for software release time determination as well.

  9. Differential item functioning analysis of the Vanderbilt Expertise Test for cars.

    Science.gov (United States)

    Lee, Woo-Yeol; Cho, Sun-Joo; McGugin, Rankin W; Van Gulick, Ana Beth; Gauthier, Isabel

    2015-01-01

    The Vanderbilt Expertise Test for cars (VETcar) is a test of visual learning for contemporary car models. We used item response theory to assess the VETcar and in particular used differential item functioning (DIF) analysis to ask if the test functions the same way in laboratory versus online settings and for different groups based on age and gender. An exploratory factor analysis found evidence of multidimensionality in the VETcar, although a single dimension was deemed sufficient to capture the recognition ability measured by the test. We selected a unidimensional three-parameter logistic item response model to examine item characteristics and subject abilities. The VETcar had satisfactory internal consistency. A substantial number of items showed DIF at a medium effect size for test setting and for age group, whereas gender DIF was negligible. Because online subjects were on average older than those tested in the lab, we focused on the age groups to conduct a multigroup item response theory analysis. This revealed that most items on the test favored the younger group. DIF could be more the rule than the exception when measuring performance with familiar object categories, therefore posing a challenge for the measurement of either domain-general visual abilities or category-specific knowledge.

  10. Liver function tests and risk prediction of incident type 2 diabetes : evaluation in two independent cohorts

    NARCIS (Netherlands)

    Abbasi, Ali; Bakker, Stephan J. L.; Corpeleijn, Eva; van der A, Daphne L.; Gansevoort, Ron T.; Gans, Rijk O. B.; Peelen, Linda M.; van der Schouw, Yvonne T.; Stolk, Ronald P.; Navis, Gerjan; Spijkerman, Annemieke M. W.; Beulens, Joline W. J.

    2012-01-01

    Background: Liver function tests might predict the risk of type 2 diabetes. An independent study evaluating utility of these markers compared with an existing prediction model is yet lacking. Methods and Findings: We performed a case-cohort study, including random subcohort (6.5%) from 38,379

  11. Covariance functions across herd production levels for test day records on milk, fat, and protein yields

    NARCIS (Netherlands)

    Veerkamp, R.F.; Goddard, M.E.

    1998-01-01

    Multiple-trait BLUP evaluations of test day records require a large number of genetic parameters. This study estimated covariances with a reduced model that included covariance functions in two dimensions (stage of lactation and herd production level) and all three yield traits. Records came from

  12. "CONGENTIAL PANHYPOPITUITARISM ASSOCIATED WITH IMPAIRED LIVER FUNCTION TESTS AND CONGENITAL HEART DISEASE"

    Directory of Open Access Journals (Sweden)

    Z. Khalili-Matinzadeh

    2006-06-01

    Full Text Available The term congenital hypopituitarism defines deficiency of all of the pituitary hormones. Hypoglycemia and microphallus (in males are common findings, and some infants have shown evidence of the neonatal hepatitis syndrome. We report a case of congenital panhypopituitarism with deficiency of six major hormones and association with severe hypoglycemia, impaired liver function tests and congenital heart disease.

  13. The Effect of Error in Item Parameter Estimates on the Test Response Function Method of Linking.

    Science.gov (United States)

    Kaskowitz, Gary S.; De Ayala, R. J.

    2001-01-01

    Studied the effect of item parameter estimation for computation of linking coefficients for the test response function (TRF) linking/equating method. Simulation results showed that linking was more accurate when there was less error in the parameter estimates, and that 15 or 25 common items provided better results than 5 common items under both…

  14. Effect of Mindfulness Meditation on Perceived Stress Scores and Autonomic Function Tests of Pregnant Indian Women.

    Science.gov (United States)

    Muthukrishnan, Shobitha; Jain, Reena; Kohli, Sangeeta; Batra, Swaraj

    2016-04-01

    Various pregnancy complications like hypertension, preeclampsia have been strongly correlated with maternal stress. One of the connecting links between pregnancy complications and maternal stress is mind-body intervention which can be part of Complementary and Alternative Medicine (CAM). Biologic measures of stress during pregnancy may get reduced by such interventions. To evaluate the effect of Mindfulness meditation on perceived stress scores and autonomic function tests of pregnant Indian women. Pregnant Indian women of 12 weeks gestation were randomised to two treatment groups: Test group with Mindfulness meditation and control group with their usual obstetric care. The effect of Mindfulness meditation on perceived stress scores and cardiac sympathetic functions and parasympathetic functions (Heart rate variation with respiration, lying to standing ratio, standing to lying ratio and respiratory rate) were evaluated on pregnant Indian women. There was a significant decrease in perceived stress scores, a significant decrease of blood pressure response to cold pressor test and a significant increase in heart rate variability in the test group (pwomen. The results of this study suggest that mindfulness meditation improves parasympathetic functions in pregnant women and is a powerful modulator of the sympathetic nervous system during pregnancy.

  15. The Vitalograph - A Study of Its Role in Pulmonary Function Testing ...

    African Journals Online (AJOL)

    A dry spirometer (Vitalographt) has been examined in relation to its mechanical reproducibility, and feasibility for use in paediatric pulmonary function testing. Measurements at ATPS and BTPS indicate a -2'10% to + 13'47% variability in volume readings respectively. Measurements on 304 normal healthy children, aged 6 ...

  16. Emotional-volitional components of operator reliability. [sensorimotor function testing under stress

    Science.gov (United States)

    Mileryan, Y. A.

    1975-01-01

    Sensorimotor function testing in a tracking task under stressfull working conditions established a psychological characterization for a successful aviation pilot: Motivation significantly increased the reliability and effectiveness of their work. Their acitivities were aimed at suppressing weariness and the feeling of fear caused by the stress factors; they showed patience, endurance, persistence, and a capacity for lengthy volitional efforts.

  17. Testing for Nonuniform Differential Item Functioning with Multiple Indicator Multiple Cause Models

    Science.gov (United States)

    Woods, Carol M.; Grimm, Kevin J.

    2011-01-01

    In extant literature, multiple indicator multiple cause (MIMIC) models have been presented for identifying items that display uniform differential item functioning (DIF) only, not nonuniform DIF. This article addresses, for apparently the first time, the use of MIMIC models for testing both uniform and nonuniform DIF with categorical indicators. A…

  18. Testing among functional forms: an extension of the Generalized Box-Cox formulation.

    NARCIS (Netherlands)

    Oude Lansink, A.G.J.M.; Thijssen, G.

    1998-01-01

    This paper uses the Generalized Box - Cox framework and Double Length artificial Regression to test whether different specifications of the profit function are able to mimic the technology underlying panel data of Dutch arable farms for the period 1970 - 1988. To this end, a linear GBC is developed

  19. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis

    NARCIS (Netherlands)

    Tilanus, T.B.M.; Groothuis, J.T.; Broek-Pastoor, J.M.C. ten; Feuth, T.; Heijdra, Y.F.; Slenders, J.P.L.; Doorduin, J.; Engelen, B.G.M. van; Kampelmacher, M.J.; Raaphorst, J.

    2017-01-01

    BACKGROUND: Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown

  20. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis

    NARCIS (Netherlands)

    Tilanus, T. B. M.; Groothuis, J. T.; TenBroek-Pastoor, J. M. C.; Feuth, T. B.; Heijdra, Y. F.; Slenders, J. P. L.; Doorduin, J.; van Engelen, B. G.; Kampelmacher, M. J.; Raaphorst, J.

    2017-01-01

    Background: Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown

  1. Does functional trait diversity predict aboveground biomass and productivity of tropical forests? Testing three alternative hypotheses

    NARCIS (Netherlands)

    Finegan, B.; Pena Claros, M.; Silva de Oliveira, A.; Ascarrunz, N.; Bret-Harte, M.S.; Carreño Rocabado, I.G.; Casanoves, F.; Diaz, S.; Eguiguren Velepucha, P.; Fernandez, F.; Licona, J.C.; Lorenzo, L.; Salgado Negret, B.; Vaz, M.; Poorter, L.

    2014-01-01

    1. Tropical forests are globally important, but it is not clear whether biodiversity enhances carbon storage and sequestration in them. We tested this relationship focusing on components of functional trait biodiversity as predictors. 2. Data are presented for three rain forests in Bolivia, Brazil

  2. Does functional trait diversity predict aboveground biomass and productivity of tropical forests? Testing three alternative hypotheses

    NARCIS (Netherlands)

    Finegan, B.; Peña Claros, M.; Oliviera, de A.; Alarcón, A.; Ascarrunz, N.; Bret-Harte, M.S.; Carreño-Rocabado, G.; Casanoves, F.; Díaz, S.; Eguiguren Velepucha, P.; Fernandez, F.; Licona, J.C.; Lorenzo, L.; Salgado Negret, B.; Vaz, M.; Poorter, L.

    2015-01-01

    Tropical forests are globally important, but it is not clear whether biodiversity enhances carbon storage and sequestration in them. We tested this relationship focusing on components of functional trait biodiversity as predictors. Data are presented for three rain forests in Bolivia, Brazil and

  3. Studying the Effects of Fasting during Ramadan on Pulmonary Functioning Test and Asthma Severity

    Directory of Open Access Journals (Sweden)

    Seyyed Hassan Adeli

    2015-03-01

    Full Text Available Background and Objectives: Studies have shown that fasting can have an impact on the course and severity of chronic diseases. There are a few studies on the association of fasting and asthma. Therefore, this study has been conducted with the purpose of examining the effects of fasting on asthma severity and pulmonary functioning tests. Methods: 30 patients with asthma who attended a pulmonology clinic in Qom were enrolled in this study. The severity of patients’ asthma has been studied by questionnaire and spirometry of pulmonary functioning in the month of Shaban, Ramadan and Shawwal. The results of Asthma Control Questionnaire and the pulmonary functioning tests in three months have been compared. Results: The average age of patients was 43.42 years and 43.3% of patients were males. The Average score for asthma severity questionnaire in three months were 20.4, 21 and 20.17 respectively. Statistically, there haven’t been any significant differences between the results of pulmonary functioning test and asthma severity before Ramadan (Shaban, during Ramadan and after that (Shawwal. Conclusion: The findings of this study showed that fasting in patients with asthma has no effect on pulmonary function and asthma severity.

  4. The Lung Screen Uptake Trial (LSUT): protocol for a randomised controlled demonstration lung cancer screening pilot testing a targeted invitation strategy for high risk and 'hard-to-reach' patients.

    Science.gov (United States)

    Quaife, Samantha L; Ruparel, Mamta; Beeken, Rebecca J; McEwen, Andy; Isitt, John; Nolan, Gary; Sennett, Karen; Baldwin, David R; Duffy, Stephen W; Janes, Samuel M; Wardle, Jane

    2016-04-20

    Participation in low-dose CT (LDCT) lung cancer screening offered in the trial context has been poor, especially among smokers from socioeconomically deprived backgrounds; a group for whom the risk-benefit ratio is improved due to their high risk of lung cancer. Attracting high risk participants is essential to the success and equity of any future screening programme. This study will investigate whether the observed low and biased uptake of screening can be improved using a targeted invitation strategy. A randomised controlled trial design will be used to test whether targeted invitation materials are effective at improving engagement with an offer of lung cancer screening for high risk candidates. Two thousand patients aged 60-75 and recorded as a smoker within the last five years by their GP, will be identified from primary care records and individually randomised to receive either intervention invitation materials (which take a targeted, stepped and low burden approach to information provision prior to the appointment) or control invitation materials. The primary outcome is uptake of a nurse-led 'lung health check' hospital appointment, during which patients will be offered a spirometry test, an exhaled carbon monoxide (CO) reading, and an LDCT if eligible. Initial data on demographics (i.e. age, sex, ethnicity, deprivation score) and smoking status will be collected in primary care and analysed to explore differences between attenders and non-attenders with respect to invitation group. Those who attend the lung health check will have further data on smoking collected during their appointment (including pack-year history, nicotine dependence and confidence to quit). Secondary outcomes will include willingness to be screened, uptake of LDCT and measures of informed decision-making to ensure the latter is not compromised by either invitation strategy. If effective at improving informed uptake of screening and reducing bias in participation, this invitation

  5. The predictive value of respiratory function tests for non-invasive ventilation in amyotrophic lateral sclerosis.

    Science.gov (United States)

    Tilanus, T B M; Groothuis, J T; TenBroek-Pastoor, J M C; Feuth, T B; Heijdra, Y F; Slenders, J P L; Doorduin, J; Van Engelen, B G; Kampelmacher, M J; Raaphorst, J

    2017-07-25

    Non-invasive ventilation (NIV) improves survival and quality of life in amyotrophic lateral sclerosis (ALS) patients. The timing of referral to a home ventilation service (HVS), which is in part based on respiratory function tests, has shown room for improvement. It is currently unknown which respiratory function test predicts an appropriate timing of the initiation of NIV. We analysed, retrospectively, serial data of five respiratory function tests: forced vital capacity (FVC), peak cough flow (PCF), maximum inspiratory and expiratory pressure (MIP and MEP) and sniff nasal inspiratory pressure (SNIP) in patients with ALS. Patients who had had at least one assessment of respiratory function and one visit at the HVS, were included. Our aim was to detect the test with the highest predictive value for the need for elective NIV in the following 3 months. We analysed time curves, currently used cut-off values for referral, and respiratory function test results between 'NIV indication' and 'no-NIV indication' patients. One hundred ten patients with ALS were included of whom 87 received an NIV indication; 11.5% had one assessment before receiving an NIV indication, 88.5% had two or more assessments. The NIV indication was based on complaints of hypoventilation and/or proven (nocturnal) hypercapnia. The five respiratory function tests showed a descending trend during disease progression, where SNIP showed the greatest decline within the latest 3 months before NIV indication (mean = -22%). PCF at the time of referral to the HVS significantly discriminated between the groups 'NIV-indication' and 'no NIV-indication yet' patients at the first HVS visit: 259 (±92) vs. 348 (±137) L/min, p = 0.019. PCF and SNIP showed the best predictive characteristics in terms of sensitivity. SNIP showed the greatest decline prior to NIV indication and PCF significantly differentiated 'NIV-indication' from 'no NIV-indication yet' patients with ALS. Currently used cut-off values might be

  6. NASA's Functional Task Test: Providing Information for an Integrated Countermeasure System

    Science.gov (United States)

    Bloomberg, J. J.; Feiveson, A. H.; Laurie, S. S.; Lee, S. M. C.; Mulavara, A. P.; Peters, B. T.; Platts, S. H.; Ploutz-Snyder, L. L.; Reschke, M. F.; Ryder, J. W.; hide

    2015-01-01

    Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems. These physiological changes include sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goals of the Functional Task Test (FTT) study were to determine the effects of spaceflight on functional tests that are representative of critical exploration mission tasks and to identify the key physiological factors that contribute to decrements in performance. The FTT was comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and ISS crewmembers participated in this study. Additionally, we conducted a supporting study using the FTT protocol on subjects before and after 70 days of 6? head-down bed rest. The bed rest analog allowed us to investigate the impact of body unloading in isolation on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare them with the results obtained in our spaceflight study. Spaceflight data were collected on three sessions before flight, on landing day (Shuttle only) and 1, 6 and 30 days after landing. Bed rest subjects were tested three times before bed rest and immediately after getting up from bed rest as well as 1, 6, and 12 days after reambulation. We have shown that for Shuttle, ISS and bed rest subjects, functional tasks requiring a greater demand for dynamic control of postural equilibrium (i.e. fall recovery, seat egress/obstacle avoidance during walking, object translation, jump down) showed the greatest decrement in performance. Functional tests with reduced requirements for

  7. The Mid-Term Changes of Pulmonary Function Tests After Phrenic Nerve Transfer.

    Science.gov (United States)

    Yavari, Masoud; Hassanpour, Seyed Esmail; Khodayari, Mohammad

    2016-03-01

    In the restoration of elbow flexion, the phrenic nerve has proven to be a good donor, but considering the role of the phrenic nerve in respiratory function, we cannot disregard the potential dangers of this method. In the current study, we reviewed the results of pulmonary function tests (PFT) in four patients who underwent phrenic nerve transfer. We reviewed the results of serial spirometry tests, which were performed before and after phrenic nerve transfer surgery. All patients regained Biceps power to M3 strength or above. None of our patients experienced pulmonary problems or respiratory complaints, but a significant reduction of spirometric parameters occurred after surgery. This study highlights the close link between the role of the phrenic nerve and pulmonary function, such that the use of this nerve as a transfer donor leads to spirometric impairments.

  8. The interpretation of Charpy impact test data using hyper-logistic fitting functions

    International Nuclear Information System (INIS)

    Helm, J.L.

    1996-01-01

    The hyperbolic tangent function is used almost exclusively for computer assisted curve fitting of Charpy impact test data. Unfortunately, there is no physical basis to justify the use of this function and it cannot be generalized to test data that exhibits asymmetry. Using simple physical arguments, a semi-empirical model is derived and identified as a special case of the so called hyper-logistic equation. Although one solution of this equation is the hyperbolic tangent, other more physically interpretable solutions are provided. From the mathematics of the family of functions derived from the hyper-logistic equation, several useful generalizations are made such that asymmetric and wavy Charpy data can be physically interpreted

  9. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    Science.gov (United States)

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. An investigation of the neural circuits underlying reaching and reach-to-grasp movements: from planning to execution.

    Directory of Open Access Journals (Sweden)

    Chiara eBegliomini

    2014-09-01

    Full Text Available Experimental evidence suggests the existence of a sophisticated brain circuit specifically dedicated to reach-to-grasp planning and execution, both in human and non human primates (Castiello, 2005. Studies accomplished by means of neuroimaging techniques suggest the hypothesis of a dichotomy between a reach-to-grasp circuit, involving the intraparietal area (AIP, the dorsal and ventral premotor cortices (PMd and PMv - Castiello and Begliomini, 2008; Filimon, 2010 and a reaching circuit involving the medial intraparietal area (mIP and the Superior Parieto-Occipital Cortex (SPOC (Culham et al., 2006. However, the time course characterizing the involvement of these regions during the planning and execution of these two types of movements has yet to be delineated. A functional magnetic resonance imaging (fMRI study has been conducted, including reach-to grasp and reaching only movements, performed towards either a small or a large stimulus, and Finite Impulse Response model (FIR - Henson, 2003 was adopted to monitor activation patterns from stimulus onset for a time window of 10 seconds duration. Data analysis focused on brain regions belonging either to the reaching or to the grasping network, as suggested by Castiello & Begliomini (2008.Results suggest that reaching and grasping movements planning and execution might share a common brain network, providing further confirmation to the idea that the neural underpinnings of reaching and grasping may overlap in both spatial and temporal terms (Verhagen et al., 2013.

  11. Does morphological convergence imply functional similarity? A test using the evolution of quadrupedalism in ornithischian dinosaurs.

    Science.gov (United States)

    Maidment, Susannah C R; Barrett, Paul M

    2012-09-22

    Convergent morphologies are thought to indicate functional similarity, arising because of a limited number of evolutionary or developmental pathways. Extant taxa displaying convergent morphologies are used as analogues to assess function in extinct taxa with similar characteristics. However, functional studies of extant taxa have shown that functional similarity can arise from differing morphologies, calling into question the paradigm that form and function are closely related. We test the hypothesis that convergent skeletal morphology indicates functional similarity in the fossil record using ornithischian dinosaurs. The rare transition from bipedality to quadrupedality occurred at least three times independently in this clade, resulting in a suite of convergent osteological characteristics. We use homology rather than analogy to provide an independent line of evidence about function, reconstructing soft tissues using the extant phylogenetic bracket and applying biomechanical concepts to produce qualitative assessments of muscle leverage. We also optimize character changes to investigate the sequence of character acquisition. Different lineages of quadrupedal ornithischian dinosaur stood and walked differently from each other, falsifying the hypothesis that osteological convergence indicates functional similarity. The acquisition of features correlated with quadrupedalism generally occurs in the same order in each clade, suggesting underlying developmental mechanisms that act as evolutionary constraints.

  12. Reliability and validity of videotaped functional performance tests in ACL-injured subjects

    DEFF Research Database (Denmark)

    von Porat, Anette; Holmström, Eva; Roos, Ewa

    2008-01-01

    BACKGROUND AND PURPOSE: In clinical practice, visual observation is often used to determine functional impairment and to evaluate treatment following a knee injury. The aim of this study was to evaluate the reliability and validity of observational assessments of knee movement pattern quality......, crossover hop on one leg and one-leg hop. The videos were observed by four physiotherapists, and the knee movement pattern quality, a feature of the loading strategy of the lower extremity, was scored on an 11-point rating scale. To assess the criterion validity, the observational rating was correlated...... obtained between the observers' assessment and knee flexion angle, r = 0.37-0.61. The crossover hop test or one-leg hop test was ranked as the most useful test in 172 of 192 occasions (90%) when assessing knee function. CONCLUSION: The moderate to good inter-observer reliability and the moderate criterion...

  13. Nuclear medicine liver-function tests for pregnant women and children. Pt. 2

    International Nuclear Information System (INIS)

    Krumbiegel, P.; Hirschberg, K.; Faust, H.; Guenther, K.; Schneider, G.

    1985-01-01

    A simple, non-invasive, non-radiaoactive liver-function test is proposed. After an oral dose of 3 mg methacetin per kilogram body mass, the kinetics of 15 N excretion via urine were characterized by the quotient of the 15 N amounts of excreted in two successive urine samples (Q value). The stable nitrogen isotope 15 N, was found to be an excellent and easily detectable indicator of the sum of all methacetin metabolites present in urine. Alterations in the nature or ratio of methacetin metabilites due to liver diseases could not be found. From the investigation of 11 men 3 pregnant women and 156 children, a clear difference was observed in Q values of healthy persons and patients suffering from liver-cell-activity diseases. The discriminating power of our new liver-function test is shown to be equivalent to that of the 14 CO 2 breath test. (orig.)

  14. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    Science.gov (United States)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  15. Fluctuating serotonergic function in premenstrual dysphoric disorder and premenstrual syndrome: findings from neuroendocrine challenge tests.

    Science.gov (United States)

    Inoue, Y; Terao, T; Iwata, N; Okamoto, K; Kojima, H; Okamoto, T; Yoshimura, R; Nakamura, J

    2007-02-01

    Premenstrual dysphoric disorder (PMDD) has been assumed to be a subtype of premenstrual syndrome (PMS) with depressive symptoms, such as depressive mood, tension, anxiety, and mood liability during luteal phase. At present, no conclusion has been established about serotonergic function in PMDD. The purpose of this study was to investigate the serotonergic function of PMDD subjects in comparison to PMS without PMDD subjects and normal controls via neuroendocrine challenge tests. Twenty-four women (seven with PMDD, eight with PMS without PMDD, and nine normal controls) were tested on three occasions (follicular phase, early luteal phase, and late luteal phase) receiving paroxetine 20 mg orally as a serotonergic probe at 8:00 A: .M: . Plasma ACTH and cortisol were measured prior to the administration and every hour for 6 h thereafter. As a whole, there were significant differences in serotonergic function measured by ACTH and cortisol responses to paroxetine challenge across these three groups. PMDD subjects showed higher serotonergic function in follicular phase but lower serotonergic function in luteal phase, compared with women with PMS without PMDD and normal controls. The present findings suggest that PMDD women have fluctuating serotonergic function across their menstrual cycles and that the pattern may be different from PMS without PMDD.

  16. Older people experiencing homelessness show marked impairment on tests of frontal lobe function.

    Science.gov (United States)

    Rogoz, Astrid; Burke, David

    2016-03-01

    Reported rates of mild and moderate cognitive impairment in older people experiencing homelessness range from 5-80%. The objective of this study was to determine the prevalence and characteristics of cognitive impairment in older people experiencing homelessness in the inner city of Sydney, Australia. Men and women experiencing homelessness aged 45 years and over in the inner city were screened for cognitive impairment. Participants who scored 26 or below on the mini-mental state examination and/or were impaired on any one of the clock-drawing test, the verbal fluency test and the trail-making test, part B were then assessed with a semi-structured interview, including the 21-item Depression Anxiety Stress Scale and the 12-item General Health Questionnaire. Screening of 144 men and 27 women aged between 45 years and 93 years identified cognitive impairment in 78%. Subsequently, high rates of mental and physical illness were identified, and 75% of subjects who were cognitively impaired performed poorly on frontal lobe tests. The trail-making test, part B was the most sensitive measure of frontal function. This study demonstrated that a large majority of older people experiencing homelessness, in the inner city of a high-income country, showed impairment on tests of frontal lobe function, a finding that could have significant implications for any medical or psychosocial intervention. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Assessment of cognitive functions after prophylactic and therapeutic whole brain irradiation using neuropsychological testing

    International Nuclear Information System (INIS)

    Penitzka, S.; Wannenmacher, M.; Steinvorth, S.; MIT, Cambridge, MT; Sehlleier, S.; Universitaetsklinikum Wuerzburg; Fuss, M.; Texas Univ., San Antonio, TX; Wenz, F.; Universitaetsklinikum Mannheim

    2002-01-01

    Purpose: Aim of this study was the assessment of neuropsychological changes after whole brain irradiation. Patients and Method: 64 patients were tested before, and 29 after whole brain irradiation, including 28 patients with small cell lung cancer (SCLC) before prophylactic cranial irradiation (PCI) and 36 patients with cerebral metastases before therapeutic cranial irradiation (TCI), as well as 14 patients after PCI and 15 after TCI (Table 1). Intelligence, attention and memory were assessed applying a 90-minute test battery of standardized, neuropsychological tests (Table 3). Results: Patients with SCLC showed test results significantly below average before PCI (n=28, mean IQ=83, SD=17). Neither after PCI, nor after TCI the tested neuropsychological functions decreased significantly (Tables 4, 5). A comparison between SCLC-patients with and without cerebral metastases before whole brain irradiation showed better test-results in patients with cerebral metastases and fewer cycles of preceding chemotherapy (Table 7). Conclusion: Neuropsychological capacity in patients with SCLC was impaired even before PCI. Possible reason is the preceding chemotherapy. Whole brain irradiation did not induce a significant decline of cognitive functions in patients with PCI or TCI. A decline in a longer follow-up nevertheless seems possible. (orig.) [de

  18. A Functional Neuroimaging Analysis of the Trail Making Test-B: Implications for Clinical Application

    Directory of Open Access Journals (Sweden)

    Mark D. Allen

    2011-01-01

    Full Text Available Recent progress has been made using fMRI as a clinical assessment tool, often employing analogues of traditional “paper and pencil” tests. The Trail Making Test (TMT, popular for years as a neuropsychological exam, has been largely ignored in the realm of neuroimaging, most likely because its physical format and administration does not lend itself to straightforward adaptation as an fMRI paradigm. Likewise, there is relatively more ambiguity about the neural systems associated with this test than many other tests of comparable clinical use. In this study, we describe an fMRI version of Trail Making Test-B (TMTB that maintains the core functionality of the TMT while optimizing its use for both research and clinical settings. Subjects (N = 32 were administered the Functional Trail Making Test-B (f-TMTB. Brain region activations elicited by the f-TMTB were consistent with expectations given by prior TMT neurophysiological studies, including significant activations in the ventral and dorsal visual pathways and the medial pre-supplementary motor area. The f-TMTB was further evaluated for concurrent validity with the traditional TMTB using an additional sample of control subjects (N = 100. Together, these results support the f-TMTB as a viable neuroimaging adaptation of the TMT that is optimized to evoke maximally robust fMRI activation with minimal time and equipment requirements.

  19. Seismic functional qualification of active mechanical and electrical components based on shaking table testing

    International Nuclear Information System (INIS)

    Jurukovski, D.

    1999-01-01

    The seismic testing for qualification of one sample of the NPP Kozloduy Control Panel type YKTC was carried out under Research Contract no: 8008/Rl, entitled: 'Seismic Functional Qualification of Active Mechanical and Electrical Components Based on Shaking Table Testing'. The tested specimen was selected by the Kozloduy NPP staff, Section 'TIA-2' (Technical Instrumentation and Automatics), however the seismic input parameters were selected by the NPP Kozloduy staff, Section HTS and SC (Hydro-Technical Systems and Engineering Structures). The applied methodology was developed by the Institute of Earthquake Engineering and Engineering Seismology staff. This report presents all relevant items related to the selected specimen seismic testing for seismic qualification such as: description of the tested specimen, mounting conditions on the shaking table, selection of seismic input parameters and creation of seismic excitations, description of the testing equipment, explanation of the applied methodology, 'on line' and 'off line' monitoring of the tested specimen, functioning capabilities, discussion of the results and their presentation and finally conclusions and recommendations. In this partial project report, two items are presented. The first item presents a review of the existing and used regulations for performing of the seismic and vibratory withstand testing of electro-mechanical equipment. The selection is made based on MEA, IEEE, IEC and former Soviet Union regulations. The second item presents the abstracts of all the tests performed at the Institute of Earthquake Engineering and Engineering Seismology in Skopje. The selected regulations, the experience of the Institute that has been gathered for the last seventeen years and some theoretical and experimental research will be the basis for further investigations for development of a synthesised methodology for seismic qualification of differently categorized equipment for nuclear power plants

  20. Pulmonary function tests correlated with thoracic volumes in adolescent idiopathic scoliosis.

    Science.gov (United States)

    Ledonio, Charles Gerald T; Rosenstein, Benjamin E; Johnston, Charles E; Regelmann, Warren E; Nuckley, David J; Polly, David W

    2017-01-01

    Scoliosis deformity has been linked with deleterious changes in the thoracic cavity that affect pulmonary function. The causal relationship between spinal deformity and pulmonary function has yet to be fully defined. It has been hypothesized that deformity correction improves pulmonary function by restoring both respiratory muscle efficiency and increasing the space available to the lungs. This research aims to correlate pulmonary function and thoracic volume before and after scoliosis correction. Retrospective correlational analysis between thoracic volume modeling from plain x-rays and pulmonary function tests was conducted. Adolescent idiopathic scoliosis patients enrolled in a multicenter database were sorted by pre-operative Total Lung Capacities (TLC) % predicted values from their Pulmonary Function Tests (PFT). Ten patients with the best and ten patients with the worst TLC values were included. Modeled thoracic volume and TLC values were compared before and 2 years after surgery. Scoliosis correction resulted in an increase in the thoracic volume for patients with the worst initial TLCs (11.7%) and those with the best initial TLCs (12.5%). The adolescents with the most severe pulmonary restriction prior to surgery strongly correlated with post-operative change in total lung capacity and thoracic volume (r 2  = 0.839; p volume in this group was 373.1 cm 3 (11.7%) which correlated with a 21.2% improvement in TLC. Scoliosis correction in adolescents was found to increase thoracic volume and is strongly correlated with improved TLC in cases with severe restrictive pulmonary function, but no correlation was found in cases with normal pulmonary function. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:175-182, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  1. Muscle Force-Velocity Relationships Observed in Four Different Functional Tests.

    Science.gov (United States)

    Zivkovic, Milena Z; Djuric, Sasa; Cuk, Ivan; Suzovic, Dejan; Jaric, Slobodan

    2017-02-01

    The aims of the present study were to investigate the shape and strength of the force-velocity relationships observed in different functional movement tests and explore the parameters depicting force, velocity and power producing capacities of the tested muscles. Twelve subjects were tested on maximum performance in vertical jumps, cycling, bench press throws, and bench pulls performed against different loads. Thereafter, both the averaged and maximum force and velocity variables recorded from individual trials were used for force-velocity relationship modeling. The observed individual force-velocity relationships were exceptionally strong (median correlation coefficients ranged from r = 0.930 to r = 0.995) and approximately linear independently of the test and variable type. Most of the relationship parameters observed from the averaged and maximum force and velocity variable types were strongly related in all tests (r = 0.789-0.991), except for those in vertical jumps (r = 0.485-0.930). However, the generalizability of the force-velocity relationship parameters depicting maximum force, velocity and power of the tested muscles across different tests was inconsistent and on average moderate. We concluded that the linear force-velocity relationship model based on either maximum or averaged force-velocity data could provide the outcomes depicting force, velocity and power generating capacity of the tested muscles, although such outcomes can only be partially generalized across different muscles.

  2. Functional assessment of the ex vivo vocal folds through biomechanical testing: A review

    Science.gov (United States)

    Dion, Gregory R.; Jeswani, Seema; Roof, Scott; Fritz, Mark; Coelho, Paulo; Sobieraj, Michael; Amin, Milan R.; Branski, Ryan C.

    2016-01-01

    The human vocal folds are complex structures made up of distinct layers that vary in cellular and extracellular composition. The mechanical properties of vocal fold tissue are fundamental to the study of both the acoustics and biomechanics of voice production. To date, quantitative methods have been applied to characterize the vocal fold tissue in both normal and pathologic conditions. This review describes, summarizes, and discusses the most commonly employed methods for vocal fold biomechanical testing. Force-elongation, torsional parallel plate rheometry, simple-shear parallel plate rheometry, linear skin rheometry, and indentation are the most frequently employed biomechanical tests for vocal fold tissues and each provide material properties data that can be used to compare native tissue verses diseased for treated tissue. Force-elongation testing is clinically useful, as it allows for functional unit testing, while rheometry provides physiologically relevant shear data, and nanoindentation permits micrometer scale testing across different areas of the vocal fold as well as whole organ testing. Thoughtful selection of the testing technique during experimental design to evaluate a hypothesis is important to optimizing biomechanical testing of vocal fold tissues. PMID:27127075

  3. Expert Assessment of Conditions for Accredited Quality Management System Functioning in Testing Laboratories

    Science.gov (United States)

    Mytych, Joanna; Ligarski, Mariusz J.

    2018-03-01

    The quality management systems compliant with the ISO 9001:2009 have been thoroughly researched and described in detail in the world literature. The accredited management systems used in the testing laboratories and compliant with the ISO/IEC 17025:2005 have been mainly described in terms of the system design and implementation. They have also been investigated from the analytical point of view. Unfortunately, a low number of studies concerned the management system functioning in the accredited testing laboratories. The aim of following study was to assess the management system functioning in the accredited testing laboratories in Poland. On 8 October 2015, 1,213 accredited testing laboratories were present in Poland. They investigated various scientific areas and substances/objects. There are more and more such laboratories that have various problems and different long-term experience when it comes to the implementation, maintenance and improvement of the management systems. The article describes the results of the conducted expert assessment (survey) carried out to examine the conditions for the functioning of a management system in an accredited laboratory. It also focuses on the characteristics of the accredited research laboratories in Poland. The authors discuss the selection of the external and internal conditions that may affect the accredited management system. They show how the experts assessing the selected conditions were chosen. The survey results are also presented.

  4. An objective measure of physical function of elderly outpatients. The Physical Performance Test.

    Science.gov (United States)

    Reuben, D B; Siu, A L

    1990-10-01

    Direct observation of physical function has the advantage of providing an objective, quantifiable measure of functional capabilities. We have developed the Physical Performance Test (PPT), which assesses multiple domains of physical function using observed performance of tasks that simulate activities of daily living of various degrees of difficulty. Two versions are presented: a nine-item scale that includes writing a sentence, simulated eating, turning 360 degrees, putting on and removing a jacket, lifting a book and putting it on a shelf, picking up a penny from the floor, a 50-foot walk test, and climbing stairs (scored as two items); and a seven-item scale that does not include stairs. The PPT can be completed in less than 10 minutes and requires only a few simple props. We then tested the validity of PPT using 183 subjects (mean age, 79 years) in six settings including four clinical practices (one of Parkinson's disease patients), a board-and-care home, and a senior citizens' apartment. The PPT was reliable (Cronbach's alpha = 0.87 and 0.79, interrater reliability = 0.99 and 0.93 for the nine-item and seven-item tests, respectively) and demonstrated concurrent validity with self-reported measures of physical function. Scores on the PPT for both scales were highly correlated (.50 to .80) with modified Rosow-Breslau, Instrumental and Basic Activities of Daily Living scales, and Tinetti gait score. Scores on the PPT were more moderately correlated with self-reported health status, cognitive status, and mental health (.24 to .47), and negatively with age (-.24 and -.18). Thus, the PPT also demonstrated construct validity. The PPT is a promising objective measurement of physical function, but its clinical and research value for screening, monitoring, and prediction will have to be determined.

  5. Lower extremity functional tests and risk of injury in division iii collegiate athletes.

    Science.gov (United States)

    Brumitt, Jason; Heiderscheit, Bryan C; Manske, Robert C; Niemuth, Paul E; Rauh, Mitchell J

    2013-06-01

    Functional tests have been used primarily to assess an athlete's fitness or readiness to return to sport. The purpose of this prospective cohort study was to determine the ability of the standing long jump (SLJ) test, the single-leg hop (SLH) for distance test, and the lower extremity functional test (LEFT) as preseason screening tools to identify collegiate athletes who may be at increased risk for a time-loss sports-related low back or lower extremity injury. A total of 193 Division III athletes from 15 university teams (110 females, age 19.1 ± 1.1 y; 83 males, age 19.5 ± 1.3 y) were tested prior to their sports seasons. Athletes performed the functional tests in the following sequence: SLJ, SLH, LEFT. The athletes were then prospectively followed during their sports season for occurrence of low back or LE injury. Female athletes who completed the LEFT in $118 s were 6 times more likely (OR=6.4, 95% CI: 1.3, 31.7) to sustain a thigh or knee injury. Male athletes who completed the LEFT in #100 s were more likely to experience a time-loss injury to the low back or LE (OR=3.2, 95% CI: 1.1, 9.5) or a foot or ankle injury (OR=6.7, 95% CI: 1.5, 29.7) than male athletes who completed the LEFT in 101 s or more. Female athletes with a greater than 10% side-to-side asymmetry between SLH distances had a 4-fold increase in foot or ankle injury (cut point: >10%; OR=4.4, 95% CI: 1.2, 15.4). Male athletes with SLH distances (either leg) at least 75% of their height had at least a 3-fold increase (OR=3.6, 95% CI: 1.2, 11.2 for the right LE; OR=3.6, 95% CI: 1.2, 11.2 for left LE) in low back or LE injury. The LEFT and the SLH tests appear useful in identifying Division III athletes at risk for a low back or lower extremity sports injury. Thus, these tests warrant further consideration as preparticipatory screening examination tools for sport injury in this population. The single-leg hop for distance and the lower extremity functional test, when administered to Division III

  6. Comparison between Genetic Algorithms and Particle Swarm Optimization Methods on Standard Test Functions and Machine Design

    DEFF Research Database (Denmark)

    Nica, Florin Valentin Traian; Ritchie, Ewen; Leban, Krisztina Monika

    2013-01-01

    , genetic algorithm and particle swarm are shortly presented in this paper. These two algorithms are tested to determine their performance on five different benchmark test functions. The algorithms are tested based on three requirements: precision of the result, number of iterations and calculation time....... Both algorithms are also tested on an analytical design process of a Transverse Flux Permanent Magnet Generator to observe their performances in an electrical machine design application.......Nowadays the requirements imposed by the industry and economy ask for better quality and performance while the price must be maintained in the same range. To achieve this goal optimization must be introduced in the design process. Two of the best known optimization algorithms for machine design...

  7. Development of a cognitive function test using virtual reality technology: examination in healthy participants.

    Science.gov (United States)

    Sakai, Hiromi; Nagano, Akinori; Seki, Keiko; Okahashi, Sayaka; Kojima, Maki; Luo, Zhiwei

    2018-07-01

    We developed a virtual reality test to assess the cognitive function of Japanese people in near-daily-life environment, namely, a virtual shopping test (VST). In this test, participants were asked to execute shopping tasks using touch panel operations in a "virtual shopping mall." We examined differences in VST performances among healthy participants of different ages and correlations between VST and screening tests, such as the Mini-Mental State Examination (MMSE) and Everyday Memory Checklist (EMC). We included 285 healthy participants between 20 and 86 years of age in seven age groups. Therefore, each VST index tended to decrease with advancing age; differences among age groups were significant. Most VST indices had a significantly negative correlation with MMSE and significantly positive correlation with EMC. VST may be useful for assessing general cognitive decline; effects of age must be considered for proper interpretation of the VST scores.

  8. Clinical use of pulmonary function tests and high-resolution tomography in interstitial lung diseases

    International Nuclear Information System (INIS)

    Garcia C, Clara P; Mejia M, Luis F

    2010-01-01

    Diagnosis of interstitial lung diseases is generally arrived at by clinical history, physical examination, and radiologic images, especially high-resolution CT-scanning. It is important to note that, while these diseases have different clinical and histological characteristics, they share a basic pattern of abnormal lung function. With regard to high-resolution tomography, the characteristics of these diseases are similar, although there are specific differences that can be helpful for correct diagnosis. These diseases have severe consequences on respiratory gas exchange. These alterations, combined with other abnormalities of lung function, cause the signs and symptoms and have an impact on quality of life. The use of physiologic parameters is not only helpful for diagnosis, but can also assess severity, help to define the consequences of treatment, and aid in the follow-up. Although some pulmonary function tests can remain completely normal with severe radiographic findings, 10% of patients have impaired lung function before radiologic changes. High-resolution tomography is an essential imaging tool for the study of these patients. This is true not only for diagnosis, but also with regard to clinical parameters and follow-up. Its prognostic use is continually gaining importance. In this article we assess the clinical use of pulmonary function tests and high-resolution tomography in interstitial lung diseases.

  9. Wada-test, functional magnetic resonance imaging and direct electrical stimulation - brain mapping methods

    International Nuclear Information System (INIS)

    Minkin, K.; Tanova, R.; Busarski, A.; Penkov, M.; Penev, L.; Hadjidekov, V.

    2009-01-01

    Modern neurosurgery requires accurate preoperative and intraoperative localization of brain pathologies but also of brain functions. The presence of individual variations in healthy subjects and the shift of brain functions in brain diseases provoke the introduction of various methods for brain mapping. The aim of this paper was to analyze the most widespread methods for brain mapping: Wada-test, functional magnetic resonance imaging (fMRI) and intraoperative direct electrical stimulation (DES). This study included 4 patients with preoperative brain mapping using Wada-test and fMRI. Intraoperative mapping with DES during awake craniotomy was performed in one case. The histopathological diagnosis was low-grade glioma in 2 cases, cortical dysplasia (1 patient) and arteriovenous malformation (1 patient). The brain mapping permits total lesion resection in three of four patients. There was no new postoperative deficit despite surgery near or within functional brain areas. Brain plasticity provoking shift of eloquent areas from their usual locations was observed in two cases. The brain mapping methods allow surgery in eloquent brain areas recognized in the past as 'forbidden areas'. Each method has advantages and disadvantages. The precise location of brain functions and pathologies frequently requires combination of different brain mapping methods. (authors)

  10. Development and testing of transfer functions for generating quantitative climatic estimates from Australian pollen data

    Science.gov (United States)

    Cook, Ellyn J.; van der Kaars, Sander

    2006-10-01

    We review attempts to derive quantitative climatic estimates from Australian pollen data, including the climatic envelope, climatic indicator and modern analogue approaches, and outline the need to pursue alternatives for use as input to, or validation of, simulations by models of past, present and future climate patterns. To this end, we have constructed and tested modern pollen-climate transfer functions for mainland southeastern Australia and Tasmania using the existing southeastern Australian pollen database and for northern Australia using a new pollen database we are developing. After testing for statistical significance, 11 parameters were selected for mainland southeastern Australia, seven for Tasmania and six for northern Australia. The functions are based on weighted-averaging partial least squares regression and their predictive ability evaluated against modern observational climate data using leave-one-out cross-validation. Functions for summer, annual and winter rainfall and temperatures are most robust for southeastern Australia, while in Tasmania functions for minimum temperature of the coldest period, mean winter and mean annual temperature are the most reliable. In northern Australia, annual and summer rainfall and annual and summer moisture indexes are the strongest. The validation of all functions means all can be applied to Quaternary pollen records from these three areas with confidence. Copyright

  11. Comparison of muscle/lean mass measurement methods: correlation with functional and biochemical testing.

    Science.gov (United States)

    Buehring, B; Siglinsky, E; Krueger, D; Evans, W; Hellerstein, M; Yamada, Y; Binkley, N

    2018-03-01

    DXA-measured lean mass is often used to assess muscle mass but has limitations. Thus, we compared DXA lean mass with two novel methods-bioelectric impedance spectroscopy and creatine (methyl-d3) dilution. The examined methodologies did not measure lean mass similarly and the correlation with muscle biomarkers/function varied. Muscle function tests predict adverse health outcomes better than lean mass measurement. This may reflect limitations of current mass measurement methods. Newer approaches, e.g., bioelectric impedance spectroscopy (BIS) and creatine (methyl-d3) dilution (D3-C), may more accurately assess muscle mass. We hypothesized that BIS and D3-C measured muscle mass would better correlate with function and bone/muscle biomarkers than DXA measured lean mass. Evaluations of muscle/lean mass, function, and serum biomarkers were obtained in older community-dwelling adults. Mass was assessed by DXA, BIS, and orally administered D3-C. Grip strength, timed up and go, and jump power were examined. Potential muscle/bone serum biomarkers were measured. Mass measurements were compared with functional and serum data using regression analyses; differences between techniques were determined by paired t tests. Mean (SD) age of the 112 (89F/23M) participants was 80.6 (6.0) years. The lean/muscle mass assessments were correlated (.57-.88) but differed (p Lean mass measures were unrelated to the serum biomarkers measured. These three methodologies do not similarly measure muscle/lean mass and should not be viewed as being equivalent. Functional tests assessing maximal muscle strength/power (grip strength and jump power) correlated with all mass measures whereas gait speed was not. None of the selected serum measures correlated with mass. Efforts to optimize muscle mass assessment and identify their relationships with health outcomes are needed.

  12. Differential Item Functioning (DIF) among Spanish-Speaking English Language Learners (ELLs) in State Science Tests

    Science.gov (United States)

    Ilich, Maria O.

    Psychometricians and test developers evaluate standardized tests for potential bias against groups of test-takers by using differential item functioning (DIF). English language learners (ELLs) are a diverse group of students whose native language is not English. While they are still learning the English language, they must take their standardized tests for their school subjects, including science, in English. In this study, linguistic complexity was examined as a possible source of DIF that may result in test scores that confound science knowledge with a lack of English proficiency among ELLs. Two years of fifth-grade state science tests were analyzed for evidence of DIF using two DIF methods, Simultaneous Item Bias Test (SIBTest) and logistic regression. The tests presented a unique challenge in that the test items were grouped together into testlets---groups of items referring to a scientific scenario to measure knowledge of different science content or skills. Very large samples of 10, 256 students in 2006 and 13,571 students in 2007 were examined. Half of each sample was composed of Spanish-speaking ELLs; the balance was comprised of native English speakers. The two DIF methods were in agreement about the items that favored non-ELLs and the items that favored ELLs. Logistic regression effect sizes were all negligible, while SIBTest flagged items with low to high DIF. A decrease in socioeconomic status and Spanish-speaking ELL diversity may have led to inconsistent SIBTest effect sizes for items used in both testing years. The DIF results for the testlets suggested that ELLs lacked sufficient opportunity to learn science content. The DIF results further suggest that those constructed response test items requiring the student to draw a conclusion about a scientific investigation or to plan a new investigation tended to favor ELLs.

  13. The twelve-flavor β-function and dilaton tests of the sextet scalar

    Directory of Open Access Journals (Sweden)

    Fodor Zoltan

    2018-01-01

    Full Text Available We discuss near-conformal gauge theories beyond the standard model (BSM where interesting results on the twelve-flavor β-function of massless fermions in the fundamental representation of the SU(3 color gauge group and dilaton tests of the light scalar with two massless fermions in the two-index symmetric tensor (sextet representation can be viewed as parts of the same BSM paradigm under investigation. The clear trend in the decreasing size of β-functions at fixed renormalized gauge coupling is interpreted as a first indicator how the conformal window (CW is approached in correlation with emergent near-conformal light scalars. BSM model building close to the CW will be influenced by differing expectations on the properties of the emergent light 0++ scalar either as a σ-particle of chiral symmetry breaking (ΧS B, or as a dilaton of scale symmetry breaking. The twelve-flavor β-function emerges as closest to the CW, perhaps near-conformal, or perhaps with an infrared fixed point (IRFP at some unexplored strong coupling inside the CW. It is premature to speculate on dilaton properties of the twelveflavor model since the near-conformal realization remains an open question. However, it is interesting and important to investigate dilaton tests of the light sextet scalar whose β-function is closest to the CW in the symmetry breaking phase and emerges as the leading candidate for dilaton tests of the light scalar. We report results from high precision analysis of the twelve-flavor β-function [1] refuting its published IRFP [2, 3]. We present our objections to recent claims [4, 5] for non-universal behavior of staggered fermions used in our analysis. We also report our first analysis of dilaton tests of the light 0++ scalar in the sextet model and comment on related post-conference developments. The dilaton test is the main thrust of this conference contribution including presentation #405 on the nf = 12 β-function and presentation #260 on dilaton

  14. Preseason Functional Movement Screen Component Tests Predict Severe Contact Injuries in Professional Rugby Union Players.

    Science.gov (United States)

    Tee, Jason C; Klingbiel, Jannie F G; Collins, Robert; Lambert, Mike I; Coopoo, Yoga

    2016-11-01

    Tee, JC, Klingbiel, JFG, Collins, R, Lambert, MI, and Coopoo, Y. Preseason Functional Movement Screen component tests predict severe contact injuries in professional rugby union players. J Strength Cond Res 30(11): 3194-3203, 2016-Rugby union is a collision sport with a relatively high risk of injury. The ability of the Functional Movement Screen (FMS) or its component tests to predict the occurrence of severe (≥28 days) injuries in professional players was assessed. Ninety FMS test observations from 62 players across 4 different time periods were compared with severe injuries sustained during 6 months after FMS testing. Mean composite FMS scores were significantly lower in players who sustained severe injury (injured 13.2 ± 1.5 vs. noninjured 14.5 ± 1.4, Effect Size = 0.83, large) because of differences in in-line lunge (ILL) and active straight leg raise scores (ASLR). Receiver-operated characteristic curves and 2 × 2 contingency tables were used to determine that ASLR (cut-off 2/3) was the injury predictor with the greatest sensitivity (0.96, 95% confidence interval [CI] = 0.79-1.0). Adding the ILL in combination with ASLR (ILL + ASLR) improved the specificity of the injury prediction model (ASLR specificity = 0.29, 95% CI = 0.18-0.43 vs. ASLR + ILL specificity = 0.53, 95% CI = 0.39-0.66, p ≤ 0.05). Further analysis was performed to determine whether FMS tests could predict contact and noncontact injuries. The FMS composite score and various combinations of component tests (deep squat [DS] + ILL, ILL + ASLR, and DS + ILL + ASLR) were all significant predictors of contact injury. The FMS composite score also predicted noncontact injury, but no component test or combination thereof produced a similar result. These findings indicate that low scores on various FMS component tests are risk factors for injury in professional rugby players.

  15. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Science.gov (United States)

    Tidstrand, Johan; Horneij, Eva

    2009-01-01

    Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs). Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ) and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0), for sitting on a Bobath ball good (κ: 0.79) and very good (κ: 0.88) and for the unilateral pelvic lift: good (κ: 0.61) and moderate (κ: 0.47). Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their ability to evaluate lumbar

  16. Inter-rater reliability of three standardized functional tests in patients with low back pain

    Directory of Open Access Journals (Sweden)

    Tidstrand Johan

    2009-06-01

    Full Text Available Abstract Background Of all patients with low back pain, 85% are diagnosed as "non-specific lumbar pain". Lumbar instability has been described as one specific diagnosis which several authors have described as delayed muscular responses, impaired postural control as well as impaired muscular coordination among these patients. This has mostly been measured and evaluated in a laboratory setting. There are few standardized and evaluated functional tests, examining functional muscular coordination which are also applicable in the non-laboratory setting. In ordinary clinical work, tests of functional muscular coordination should be easy to apply. The aim of this present study was to therefore standardize and examine the inter-rater reliability of three functional tests of muscular functional coordination of the lumbar spine in patients with low back pain. Methods Nineteen consecutive individuals, ten men and nine women were included. (Mean age 42 years, SD ± 12 yrs. Two independent examiners assessed three tests: "single limb stance", "sitting on a Bobath ball with one leg lifted" and "unilateral pelvic lift" on the same occasion. The standardization procedure took altered positions of the spine or pelvis and compensatory movements of the free extremities into account. The inter-rater reliability was analyzed by Cohen's kappa coefficient (κ and by percentage agreement. Results The inter-rater reliability for the right and the left leg respectively was: for the single limb stance very good (κ: 0.88–1.0, for sitting on a Bobath ball good (κ: 0.79 and very good (κ: 0.88 and for the unilateral pelvic lift: good (κ: 0.61 and moderate (κ: 0.47. Conclusion The present study showed good to very good inter-rater reliability for two standardized tests, that is, the single-limb stance and sitting on a Bobath-ball with one leg lifted. Inter-rater reliability for the unilateral pelvic lift test was moderate to good. Validation of the tests in their

  17. Variability of pulmonary function test in healthy children, asthmatic and with chronicle lung disease

    International Nuclear Information System (INIS)

    Rodriguez Martinez, Carlos; Sossa, Monica Patricia; Cortez, Eliana; Mallol, Javier

    2004-01-01

    Comparison of sequential pulmonary function tests in the same individual can be used to assess progression of a disease, response to therapy, or response to bronchial provocation. These types of comparisons require an understanding of the factors influencing the variability normally in repeat measurements of lung function. To avoid misleading conclusions about changes in serial measurements, the degree of variability of each test must be considered in their interpretation. The purpose of this study was to examine the degree of intrasubject variability for pulmonary function testing in healthy, asthmatic and children with chronic lung disease (CLD). The tests examined were spirometry, and body plethysmography determination of lung volumes. We studied 21 healthy children, 19 asthmatic patients and 19 children with CLD, testing were done on nine occasions, three times within a day, on three different days, over a period of two months. Short-term variability was defined as the coefficient of variation for the s ix measurements made on days 1 and 2, and the long-term variability as the CV of the nine measurements made on days 1, 2 and 3. Based on the CV measures, children with CLD had significantly more variability in all spirometric values compared with healthy and asthmatic children, except for PEF (P< 0.05) children with CLD had a significantly lower CV for TGV and FRC compared with the other two groups (p < 0.05). Asthmatic children had a significantly higher CV for RV and RV/TLC compared with healthy and children with CLD (p < 0.05). We propose a method to consider changes in pulmonary function tests as significant. The degree of variability and an estimate of the percent change for significance of spirometric and plethysmographic tests must be considered in the interpretation of data to avoid misleading conclusions. The variability of spirometric pulmonary function data in healthy subjects was smaller than that for patients with pulmonary disease, so larger

  18. Forced deflation pulmonary function test: a novel method to evaluate lung function in infants and young children.

    Science.gov (United States)

    Goyal, Rakesh K; Ibrahimova, Azada; Escolar, Maria L; Szabolcs, Paul; Vander Lugt, Mark T.; Windreich, Randy M; Weiner, Daniel J

    2017-04-01

    We describe the safety and feasibility of a forced deflation pulmonary function test (dPFT) in infants and young children. Fifty-two dPFT studies were performed in 26 patients (median age, 1.4 years). Forced vital capacity (FVC) and forced expiratory flow (FEF 75 ) were normal in all except one case, but respiratory system compliance (Crs) was reduced in 24% patients. There were no significant differences in pre-blood and marrow transplantation FVC, FEF 75 , and Crs between those patients who did and those who did not have posttransplant pulmonary complications. A larger study is needed to determine the prevalence and significance of PFT abnormalities in this age group. © 2016 Wiley Periodicals, Inc.

  19. Clinical history and biologic age predicted falls better than objective functional tests.

    Science.gov (United States)

    Gerdhem, Paul; Ringsberg, Karin A M; Akesson, Kristina; Obrant, Karl J

    2005-03-01

    Fall risk assessment is important because the consequences, such as a fracture, may be devastating. The objective of this study was to find the test or tests that best predicted falls in a population-based sample of elderly women. The fall-predictive ability of a questionnaire, a subjective estimate of biologic age and objective functional tests (gait, balance [Romberg and sway test], thigh muscle strength, and visual acuity) were compared in 984 randomly selected women, all 75 years of age. A recalled fall was the most important predictor for future falls. Only recalled falls and intake of psycho-active drugs independently predicted future falls. Women with at least five of the most important fall predictors (previous falls, conditions affecting the balance, tendency to fall, intake of psychoactive medication, inability to stand on one leg, high biologic age) had an odds ratio of 11.27 (95% confidence interval 4.61-27.60) for a fall (sensitivity 70%, specificity 79%). The more time-consuming objective functional tests were of limited importance for fall prediction. A simple clinical history, the inability to stand on one leg, and a subjective estimate of biologic age were more important as part of the fall risk assessment.

  20. Routine testing of liver function before and after elective laparoscopic cholecystectomy: is it necessary?

    LENUS (Irish Health Repository)

    Ahmad, Nasir Zaheer

    2012-01-31

    BACKGROUND AND OBJECTIVES: Liver function tests (LFTs) include alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyl transpeptidase (GGT), alkaline phosphatase (ALP), and bilirubin. The role of routine testing before and after laparoscopic cholecystectomy was evaluated in this study. PATIENTS AND METHODS: A total of 355 patients were retrospectively analyzed by examining the LFTs the day before, the day after, and 3 weeks after the surgery. The Wilcoxon signed-rank test and Student t test were performed to determine statistical significance. RESULTS: Alterations in the serum AST, ALT, and GGT were seen on the first postoperative day. Minor changes were seen in bilirubin and ALP. An overall disturbance in the LFTs was seen in more than two-thirds of the cases. Repeat LFTs performed after 3 weeks on follow-up were found to be within normal limits. CONCLUSION: Mild-to-moderate elevation in preoperative LFTs may not be associated with any deleterious effect, and, in the absence of clinical indications, routine preoperative or postoperative liver function testing is unnecessary.

  1. Improving ATLAS grid site reliability with functional tests using HammerCloud

    Science.gov (United States)

    Elmsheuser, Johannes; Legger, Federica; Medrano Llamas, Ramon; Sciacca, Gianfranco; van der Ster, Dan

    2012-12-01

    With the exponential growth of LHC (Large Hadron Collider) data in 2011, and more coming in 2012, distributed computing has become the established way to analyse collider data. The ATLAS grid infrastructure includes almost 100 sites worldwide, ranging from large national computing centers to smaller university clusters. These facilities are used for data reconstruction and simulation, which are centrally managed by the ATLAS production system, and for distributed user analysis. To ensure the smooth operation of such a complex system, regular tests of all sites are necessary to validate the site capability of successfully executing user and production jobs. We report on the development, optimization and results of an automated functional testing suite using the HammerCloud framework. Functional tests are short lightweight applications covering typical user analysis and production schemes, which are periodically submitted to all ATLAS grid sites. Results from those tests are collected and used to evaluate site performances. Sites that fail or are unable to run the tests are automatically excluded from the PanDA brokerage system, therefore avoiding user or production jobs to be sent to problematic sites.

  2. ESO telbib: Linking In and Reaching Out

    Science.gov (United States)

    Grothkopf, U.; Meakins, S.

    2015-04-01

    Measuring an observatory's research output is an integral part of its science operations. Like many other observatories, ESO tracks scholarly papers that use observational data from ESO facilities and uses state-of-the-art tools to create, maintain, and further develop the Telescope Bibliography database (telbib). While telbib started out as a stand-alone tool mostly used to compile lists of papers, it has by now developed into a multi-faceted, interlinked system. The core of the telbib database is links between scientific papers and observational data generated by the La Silla Paranal Observatory residing in the ESO archive. This functionality has also been deployed for ALMA data. In addition, telbib reaches out to several other systems, including ESO press releases, the NASA ADS Abstract Service, databases at the CDS Strasbourg, and impact scores at Altmetric.com. We illustrate these features to show how the interconnected telbib system enhances the content of the database as well as the user experience.

  3. Proprioceptive body illusions modulate the visual perception of reaching distance.

    Directory of Open Access Journals (Sweden)

    Agustin Petroni

    Full Text Available The neurobiology of reaching has been extensively studied in human and non-human primates. However, the mechanisms that allow a subject to decide-without engaging in explicit action-whether an object is reachable are not fully understood. Some studies conclude that decisions near the reach limit depend on motor simulations of the reaching movement. Others have shown that the body schema plays a role in explicit and implicit distance estimation, especially after motor practice with a tool. In this study we evaluate the causal role of multisensory body representations in the perception of reachable space. We reasoned that if body schema is used to estimate reach, an illusion of the finger size induced by proprioceptive stimulation should propagate to the perception of reaching distances. To test this hypothesis we induced a proprioceptive illusion of extension or shrinkage of the right index finger while participants judged a series of LEDs as reachable or non-reachable without actual movement. Our results show that reach distance estimation depends on the illusory perceived size of the finger: illusory elongation produced a shift of reaching distance away from the body whereas illusory shrinkage produced the opposite effect. Combining these results with previous findings, we suggest that deciding if a target is reachable requires an integration of body inputs in high order multisensory parietal areas that engage in movement simulations through connections with frontal premotor areas.

  4. Binary pseudorandom test standard to determine the modulation transfer function of optical microscopes

    Science.gov (United States)

    Lacey, Ian; Anderson, Erik H.; Artemiev, Nikolay A.; Babin, Sergey; Cabrini, Stefano; Calafiore, Guiseppe; Chan, Elaine R.; McKinney, Wayne R.; Peroz, Christophe; Takacs, Peter Z.; Yashchuk, Valeriy V.

    2015-09-01

    This work reports on the development of a binary pseudo-random test sample optimized to calibrate the MTF of optical microscopes. The sample consists of a number of 1-D and 2-D patterns, with different minimum sizes of spatial artifacts from 300 nm to 2 microns. We describe the mathematical background, fabrication process, data acquisition and analysis procedure to return spatial frequency based instrument calibration. We show that the developed samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error.

  5. Analysis of unavailability related to demand failures as a function of the testing interval

    International Nuclear Information System (INIS)

    Carretero, J.A.; Pereira, M.B.; Perez Lobo, E.M.

    1998-01-01

    The unavailability related to the demand failure of a component is the sum of the contributions of the failures in demand and in waiting. An important point in PSAs is the calculation of unavailabilities of the basic events of demand failure. Several criteria are used for this, with the objective of simplifying said quantification. The information available from two nuclear power plants has been analysed, in order to determine the tendency in the models in demand and in waiting, as a function of the test intervals, the following conclusions were obtained: - There is a clear tendency for the possibility of failure in demand to increase as the interval between tests increases - The test intervals considered in PSAs are not always coherent with the estimates of real demand; this implies a penalty when using the in waiting model, due to the underlying conservatism Therefore, increasing the intervals between tests over time (a tendency studied in nuclear power plants)could cause demand due to tests to b e significantly less than that due to real actuations. This implies a need to apply test intervals based on historic demands and not on those due to historic tests, in order to avoid conservatism. (Author)

  6. Posterior cerebral artery Wada test: sodium amytal distribution and functional deficits

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H.; Schild, H.H. [Dept. of Radiology/Neuroradiology, Univ. of Bonn (Germany); Klemm, E.; Biersack, H.J. [Bonn Univ. (Germany). Klinik fuer Nuklearmedizin; Linke, D.B.; Behrends, K.; Schramm, J. [Dept. of Neurosurgery, Univ. of Bonn (Germany)

    2001-04-01

    Inadequate sodium amytal delivery to the posterior hippocampus during the intracarotid Wada test has led to development of selective tests. Our purpose was to show the sodium amytal distribution in the posterior cerebral artery (PCA) Wada test and to relate it to functional deficits during the test. We simultaneously injected 80 mg sodium amytal and 14.8 MBq {sup 99} {sup m}Tc-hexamethylpropyleneamine oxime (HMPAO) into the P2-segment of the PCA in 14 patients with temporal lobe epilepsy. To show the skull, we injected 116 MBq {sup 99} {sup m}Tc-HDP intravenously. Sodium amytal distribution was determined by high-resolution single-photon emission computed tomography (SPECT). In all patients, HMPAO was distributed throughout the parahippocampal gyrus and hippocampus; it was also seen in the occipital lobe in all cases and in the thalamus in 11. Eleven patients were awake and cooperative; one was slightly uncooperative due to speech comprehension difficulties and perseveration. All patients showed contralateral hemianopia during the test. Four patients had nominal dysphasia for 1-3 min. None developed motor deficits or had permanent neurological deficits. Neurological deficits due to inactivation of extrahippocampal areas thus do not grossly interfere with neuropsychological testing during the test. (orig.)

  7. Chaotic annealing with hypothesis test for function optimization in noisy environments

    International Nuclear Information System (INIS)

    Pan Hui; Wang Ling; Liu Bo

    2008-01-01

    As a special mechanism to avoid being trapped in local minimum, the ergodicity property of chaos has been used as a novel searching technique for optimization problems, but there is no research work on chaos for optimization in noisy environments. In this paper, the performance of chaotic annealing (CA) for uncertain function optimization is investigated, and a new hybrid approach (namely CAHT) that combines CA and hypothesis test (HT) is proposed. In CAHT, the merits of CA are applied for well exploration and exploitation in searching space, and solution quality can be identified reliably by hypothesis test to reduce the repeated search to some extent and to reasonably estimate performance for solution. Simulation results and comparisons show that, chaos is helpful to improve the performance of SA for uncertain function optimization, and CAHT can further improve the searching efficiency, quality and robustness

  8. Apparatus and test method for characterizing the temperature regulating properties of thermal functional porous polymeric materials.

    Science.gov (United States)

    Yao, Bao-Guo; Zhang, Shan; Zhang, De-Pin

    2017-05-01

    In order to evaluate the temperature regulating properties of thermal functional porous polymeric materials such as fabrics treated with phase change material microcapsules, a new apparatus was developed. The apparatus and the test method can measure the heat flux, temperature, and displacement signals during the dynamic contact and then quickly give an evaluation for the temperature regulating properties by simulating the dynamic heat transfer and temperature regulating process when the materials contact the body skin. A series of indices including the psychosensory intensity, regulating capability index, and relative regulating index were defined to characterize the temperature regulating properties. The measurement principle, the evaluation criteria and grading method, the experimental setup and the test results discussion, and the gage capability analysis of the apparatus are presented. The new apparatus provides a method for the objective measurement and evaluation of the temperature regulating properties of thermal functional porous polymeric materials.

  9. The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

    Science.gov (United States)

    Peters, B. T.; Mulavara, A. P.; Brady, R.; Miller, C. A.; Richards, J. T.; Warren, L. E.; Cohen, H. S.; Bloomberg, J. J.

    2006-01-01

    After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The

  10. Examination of relationship between 30 second wingate test performance and spirometric respiratory functions in young adults

    Directory of Open Access Journals (Sweden)

    C Arslan

    2009-07-01

    Full Text Available Objective: This work has been planed to investigate whether the correlation between one of the important component of the sports performance spirometric respiratory function (SRF and 30 s Wingate Test (WT parameters of young adults who have different physical fitness level. Materials and Methods: This work included a total of 166 subjects those are 98 young boys (20.30±1.93 and 68 young girls (19.65±2.18. The subjects were divided into two groups namely regular exercises group (EG who make a regular exercises during 4.0±1.50 years and sedentary groups (SG. Both group’s subjects have similar age, height, weight and body mass index (BMI kg/m2. All the subjects were performed spirometric respiratory function test and WT power performance test. Statistical analyses were performed by SPSS computer program and the groups were compared to each other by using Independent Samples t test calculation and the correlation relation levels were calculated by using linear regression analysis. Results: In the view of physical peculiarities, it has not been found any difference between research groups that EG and SG (P>0.05. In the meaning of the measured spirometric respiratory functions and WT power performance, with the advantage of making regular sports, according to SG groups, the boys and girls EG groups showed differences (P<0.05. The correlational relationship between the spirometric and WT power parameters; it has been observed significant correlation between peak power (PP, mean power (MP, peak power/weight (PP/Wkg, mean power/weight (MP/Wkg form WT parameters and VC, FVC, FEV1, FEV1/FVC (% FEF25-75, PEF and MVV form respiration function (P<0.05 and P<0.001. On the other hand, it has not been found any significant correlation between WT anaerobic fatigue index (AFI % and respiratory functions (P<0.05. Conclusion: In this work, the tested spirometric respiratory functions have got an active role in the WT power parameters. It has been confirmed that

  11. The Functional Task Test: Results from the One-Year Mission

    Science.gov (United States)

    Bloomberg, J. J; Batson, C. D.; Buxton, R. E.; Feiveson, A. H.; Kofman, I. S.; Laurie, S.; Lee, S. M. C.; Miller, C. A.; Mulavara, A. P.; Peters, B. T.; hide

    2017-01-01

    Exposure to the microgravity conditions of spaceflight causes astronauts to experience alterations in multiple physiological systems including sensorimotor disturbances, cardiovascular deconditioning, and loss of muscle mass and strength. Some or all of these changes might affect the ability of crewmembers to perform critical mission tasks immediately after landing on a planetary surface. The goal of our recently completed Functional Task Test (FTT) study was to determine the effects of spaceflight on functional tests that are representative of high priority exploration mission tasks and to identify the key underlying physiological factors that contribute to decrements in performance. The FTT is comprised of seven functional tests and a corresponding set of interdisciplinary physiological measures specifically targeting the sensorimotor, cardiovascular and muscular changes associated with exposure to spaceflight. Both Shuttle and International Space Station (ISS) astronauts were tested before and after spaceflight. Additionally, we conducted a supporting study in which subjects performed the FTT protocol before and after 70 days of 6 deg head-down bed rest, an analog for spaceflight. Two groups of bed rest subjects were studied: one group who performed aerobic and resistive exercise during bed rest using protocols similar to astronauts and one group who served as non-exercise controls. The bed rest analog allowed us to isolate the impact of body unloading without other spaceflight environmental factors on both functional tasks and on the underlying physiological factors that lead to decrements in performance, and then to compare those results with the results obtained in our spaceflight study. As an extension to the FTT study we collected data from one ISS crewmember who experienced 340 days in space using the same FTT protocol used previously to test spaceflight and bed rest subjects. Data were collected three times preflight and 1.7, 7.5 and 36.5 days after

  12. Using Bilateral Functional and Anthropometric Tests to Define Symmetry in Cross-Country Skiers

    Directory of Open Access Journals (Sweden)

    Björklund Glenn

    2017-12-01

    Full Text Available The aim of this study was to evaluate the symmetry of anthropometry and muscle function in cross-country skiers and their association to vertical jumping power. Twenty cross-country skiers were recruited (21.7 ± 3.8 yrs, 180.6 ± 7.6 cm, 73.2 ± 7.6 kg. Anthropometric data was obtained using an iDXA scan. VO2max was determined using the diagonal stride technique on a ski treadmill. Bilateral functional tests for the upper and lower body were the handgrip and standing heel-rise tests. Vertical jump height and power were assessed with a counter movement jump. Percent asymmetry was calculated using a symmetry index and four absolute symmetry index levels. At a group level the upper body was more asymmetrical with regard to lean muscle mass (p = 0.022, d = 0.17 and functional strength (p = 0.019, d = 0.51 than the lower body. At an individual level the expected frequencies for absolute symmetry level indexes showed the largest deviation from zero for the heel-rise test (χ2 = 16.97, p = 0.001, while the leg lean mass deviated the least (χ2 = 0.42, p = 0.517. No relationships were observed between absolute symmetry level indexes of the lower body and counter movement jump performance (p > 0.05. As a group the skiers display a more asymmetrical upper body than lower body regarding muscle mass and strength. Interestingly at the individual level, despite symmetrical lean leg muscle mass the heel-rise test showed the largest asymmetry. This finding indicates a mismatch in muscle function for the lower body.

  13. Using Bilateral Functional and Anthropometric Tests to Define Symmetry in Cross-Country Skiers.

    Science.gov (United States)

    Björklund, Glenn; Alricsson, Marie; Svantesson, Ulla

    2017-12-01

    The aim of this study was to evaluate the symmetry of anthropometry and muscle function in cross-country skiers and their association to vertical jumping power. Twenty cross-country skiers were recruited (21.7 ± 3.8 yrs, 180.6 ± 7.6 cm, 73.2 ± 7.6 kg). Anthropometric data was obtained using an iDXA scan. VO 2max was determined using the diagonal stride technique on a ski treadmill. Bilateral functional tests for the upper and lower body were the handgrip and standing heel-rise tests. Vertical jump height and power were assessed with a counter movement jump. Percent asymmetry was calculated using a symmetry index and four absolute symmetry index levels. At a group level the upper body was more asymmetrical with regard to lean muscle mass (p = 0.022, d = 0.17) and functional strength (p = 0.019, d = 0.51) than the lower body. At an individual level the expected frequencies for absolute symmetry level indexes showed the largest deviation from zero for the heel-rise test (χ2 = 16.97, p = 0.001), while the leg lean mass deviated the least (χ2 = 0.42, p = 0.517). No relationships were observed between absolute symmetry level indexes of the lower body and counter movement jump performance (p > 0.05). As a group the skiers display a more asymmetrical upper body than lower body regarding muscle mass and strength. Interestingly at the individual level, despite symmetrical lean leg muscle mass the heel-rise test showed the largest asymmetry. This finding indicates a mismatch in muscle function for the lower body.

  14. Development of computerized adaptive testing (CAT) for the EORTC QLQ-C30 physical functioning dimension

    DEFF Research Database (Denmark)

    Petersen, Morten Aa; Groenvold, Mogens; Aaronson, Neil K

    2011-01-01

    Computerized adaptive test (CAT) methods, based on item response theory (IRT), enable a patient-reported outcome instrument to be adapted to the individual patient while maintaining direct comparability of scores. The EORTC Quality of Life Group is developing a CAT version of the widely used EORTC...... QLQ-C30. We present the development and psychometric validation of the item pool for the first of the scales, physical functioning (PF)....

  15. Abnormality of thyroid function tests in geriatric population undergoing chronic dialysis

    Directory of Open Access Journals (Sweden)

    Mustafa Altay

    2014-06-01

    Conclusions: Elderly dialysis patients had higher thyroid function test abnormalities than controls. They had lower fT3 levels than controls such as young and middle age chronic dialysis patients. However, what does it mean for clinical process and how its clinical expression is not clearly known, especially in an elderly patients. Large, prospective, randomized and controlled trials are necessary for this topic. [J Contemp Med 2014; 4(2.000: 54-58

  16. Does functional trait diversity predict aboveground biomass and productivity of tropical forests? Testing three alternative hypotheses

    OpenAIRE

    Finegan, B.; Pena Claros, M.; Silva de Oliveira, A.; Ascarrunz, N.; Bret-Harte, M.S.; Carreño Rocabado, I.G.; Casanoves, F.; Diaz, S.; Eguiguren Velepucha, P.; Fernandez, F.; Licona, J.C.; Lorenzo, L.; Salgado Negret, B.; Vaz, M.; Poorter, L.

    2014-01-01

    1. Tropical forests are globally important, but it is not clear whether biodiversity enhances carbon storage and sequestration in them. We tested this relationship focusing on components of functional trait biodiversity as predictors. 2. Data are presented for three rain forests in Bolivia, Brazil and Costa Rica. Initial above-ground biomass and biomass increments of survivors, recruits and survivors + recruits (total) were estimated for trees ≥10 cm d.b.h. in 62 and 21 1.0-ha plots, respecti...

  17. Focal airtrapping at expiratory high-resolution CT: comparison with pulmonary function tests

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Hast, J.; Heussel, C.P.; Mildenberger, P.; Thelen, M.; Schlegel, J.

    2000-01-01

    This study was undertaken to determine prevalence, extent, and severity of focal airtrapping at expiratory high-resolution CT, and to compare focal airtrapping with age, gender, pulmonary function tests, and blood gas analysis. Two-hundred seventeen patients with and without pulmonary disease underwent paired inspiratory/expiratory high-resolution CT. Six scan pairs with corresponding scan levels were visually assessed for focal - not diffuse - airtrapping using a four-point scale. Pulmonary function tests and blood gas analysis were available for correlation in all patients (mean interval 5 days). Focal airtrapping with lower lung predominance was observed in 80 % of patients. Twenty-six of 26 patients with restrictive lung function impairment exhibited focal airtrapping (mean score 2.4), whereas only 72 of 98 (74 %) patients with obstruction did (mean score 1.5; p < 0.05). Fifty-eight of 70 (83 %) patients with normal lung function (mean score 1.8) and 19 of 23 (83 %) patients with mixed impairment (mean score 1.8) had focal airtrapping. Focal airtrapping showed negative correlations with static lung volumes (-0.27 to -0.37; p < 0.001) in all patients and moderate positive correlations with dynamic parameters (0.3-0.4; p < 0.001) in patients with obstruction. No significant correlations were found with age, gender, and blood gas analysis. Visual assessment of focal - not diffuse - airtrapping at expiratory high-resolution CT does not correlate with physiological evidence of obstruction as derived from pulmonary function tests since the perception of focal airtrapping requires an adequate expiratory increase in lung density. (orig.)

  18. Comparison of high resolution computed tomography and pulmonary function tests in diagnosis of mild emphysema

    International Nuclear Information System (INIS)

    Kuwano, Kazuyoshi; Matsuba, Kenichi; Ikeda, Togo

    1989-01-01

    To assess the ability of high resolution CT scan and pulmonary function tests in detecting and grading mild emphysema, we correlated the high resolution CT scan and pulmonary function tests with the pathologic grade of emphysema and the destructive index of lung specimens from 42 patients undergoing thoracotomy for solitary pulmonary nodules. Using the high resolution CT scan, we could identify the pathologic grade of mild and moderate emphysema. By measuring diffusing capacity per unit alveolar gas volume (DLco/VA), it seemed to be possible to detect the mildest degree of alveolar destruction assessed by the destructive index, which was not detected by high resolution CT scan. The reason for these results seemed to be that we assessed the severity of emphysema by detecting the air space enlargement on high resolution CT scan images caused by the destruction of alveolar walls, which were detectable by measuring DLco/VA. We conclude that it is possible to detect mild emphysema using the combination of high resolution CT scan and pulmomary function tests. (author)

  19. The effect of diltiazem on the manifestations of hyperthyroidism and thyroid function tests.

    Science.gov (United States)

    Keleştimur, F; Aksu, A

    1996-01-01

    The aim of this study is to evaluate the effect of diltiazem on the symptoms and signs of hyperthyroidism and thyroid function tests and to assess whether diltiazem can be used associated with an anti-thyroid drug, propylthiouracil. Twenty-two patients with hyperthyroidism were included in a prospective, randomized and placebo controlled study. Group 1 (n:12) patients received diltiazem, 60 mg twice a day, for 30 days. Group 2 (n:10) patients received placebo for 30 days. The patients in both groups were given propylthiouracil, 100 mg three times a day, for the last 20 days of the study period. The patients remained in the hospital during the first 10 days. A standardized hyperthyroid symptom score (HSS) and thyroid function tests including thyroid-stimulating hormone (TSH), free thyroxine (free T4), free triiodothyronine (free T3), total thyroxine (T4) and total triiodothyronine (T3) were evaluated before and after 10 and 30 days of the study period. HSS decreased from 27.80 +/- 4.54 to 22.51 +/- 4.04 after 10 days of diltiazem therapy in Group 1 (p 0.01). No significant changes in thyroid function tests have occurred in both groups after 10 days of treatment. Diltiazem can be used in patients with hyperthyroidism to alleviate adrenergic manifestations. It can also be safely combined with propylthiouracil.

  20. Test-retest reliability and cross validation of the functioning everyday with a wheelchair instrument.

    Science.gov (United States)

    Mills, Tamara L; Holm, Margo B; Schmeler, Mark

    2007-01-01

    The purpose of this study was to establish the test-retest reliability and content validity of an outcomes tool designed to measure the effectiveness of seating-mobility interventions on the functional performance of individuals who use wheelchairs or scooters as their primary seating-mobility device. The instrument, Functioning Everyday With a Wheelchair (FEW), is a questionnaire designed to measure perceived user function related to wheelchair/scooter use. Using consumer-generated items, FEW Beta Version 1.0 was developed and test-retest reliability was established. Cross-validation of FEW Beta Version 1.0 was then carried out with five samples of seating-mobility users to establish content validity. Based on the content validity study, FEW Version 2.0 was developed and administered to seating-mobility consumers to examine its test-retest reliability. FEW Beta Version 1.0 yielded an intraclass correlation coefficient (ICC) Model (3,k) of .92, p content validity results revealed that FEW Beta Version 1.0 captured 55% of seating-mobility goals reported by consumers across five samples. FEW Version 2.0 yielded ICC(3,k) = .86, p content validity of FEW Version 2.0 was confirmed. FEW Beta Version 1.0 and FEW Version 2.0 were highly stable in their measurement of participants' seating-mobility goals over a 1-week interval.

  1. Safety and Yield of Diagnostic ERCP in Liver Transplant Patients with Abnormal Liver Function Tests

    Directory of Open Access Journals (Sweden)

    Jayapal Ramesh

    2014-01-01

    Full Text Available Background. Abnormal liver enzymes postorthotopic liver transplant (OLT may indicate significant biliary pathology or organ rejection. There is very little known in the literature regarding the current role of diagnostic ERCP in this scenario. Aim. To review the utility of diagnostic ERCP in patients presenting with abnormal liver function tests in the setting of OLT. Methods. A retrospective review of diagnostic ERCPs in patients with OLT from 2002 to 2013 from a prospectively maintained, IRB approved database. Results. Of the 474 ERCPs performed in OLT patients, 210 (44.3%; 95% CI 39.8–48.8 were performed for abnormal liver function tests during the study period. Majority of patients were Caucasian (83.8%, male (62.4% with median age of 55 years (IQR 48–62 years. Biliary cannulation was successful in 99.6% of cases and findings included stricture in 45 (21.4 %; biliary stones/sludge in 23 (11%; biliary dilation alone in 31 (14.8%; and normal in 91 (43.3%. Three (1.4% patients developed mild, self-limiting pancreatitis; one patient (0.5% developed cholangitis and two (1% had postsphincterotomy bleeding. Multivariate analyses showed significant association between dilated ducts on imaging with a therapeutic outcome. Conclusion. Diagnostic ERCP in OLT patients presenting with liver function test abnormalities is safe and frequently therapeutic.

  2. Tests of potential functional barriers for laminated multilayer food packages. Part I: Low molecular weight permeants.

    Science.gov (United States)

    Simal-Gándara, J; Sarria-Vidal, M; Koorevaar, A; Rijk, R

    2000-08-01

    The advent of the functional barrier concept in food packaging has brought with it a requirement for fast tests of permeation through potential barrier materials. In such tests it would be convenient for both foodstuffs and materials below the functional barrier (sub-barrier materials) to be represented by standard simulants. By means of inverse gas chromatography, liquid paraffin spiked with appropriate permeants was considered as a potential simulant of sub-barrier materials based on polypropylene (PP) or similar polyolefins. Experiments were performed to characterize the kinetics of the permeation of low molecular weight model permeants (octene, toluene and isopropanol) from liquid paraffin, through a surrogate potential functional barrier (25 microns-thick oriented PP) into the food stimulants olive oil and 3% (w/v) acetic acid. These permeation results were interpreted in terms of three permeation kinetic models regarding the solubility of a particular model permeant in the post-barrier medium (i.e. the food simulant). The results obtained justify the development and evaluation of liquid sub-barrier simulants that would allow flexible yet rigorous testing of new laminated multilayer packaging materials.

  3. A versatile hydraulically operated respiratory servo system for ventilation and lung function testing.

    Science.gov (United States)

    Meyer, M; Slama, H

    1983-09-01

    A description is given of the design and performance of a microcomputer-controlled respiratory servo system that incorporates the characteristics of a mechanical ventilator and also allows the performance of a multitude of test procedures required for assessment of pulmonary function in paralyzed animals. The device consists of a hydraulically operated cylinder-piston assembly and solenoid valves that direct inspiratory and expiratory gas flow and also enable switching to different test gas sources. The system operates as a volume-flow-preset ventilator but may be switched to other operational cycling modes. Gas flow rates may be constant or variable. The system operates as an assister-controller and, combined with a gas analyzer, can function as a "demand" ventilator allowing for set-point control of end-tidal PCO2 and PO2. Complex breathing maneuvers for a variety of single- and multiple-breath lung function tests are automatically performed. Because of the flexibility in selection and timing of respiratory parameters, the system is particularly suitable for respiratory gas studies.

  4. Assessment of patients with multiple sclerosis according to tests of the Multiple Sclerosis Functional Composite

    Directory of Open Access Journals (Sweden)

    Anelise Ineu Figueiredo

    Full Text Available Abstract Introduction: The Multiple Sclerosis Functional Composite (MSFC is a scale that evaluates the functional and cognitive aspects of patients with multiple sclerosis (MS. Objective: To compare the performance of individuals with the relapsing-remitting form of MS (RRMS with a group of healthy subjects using the MSFC. Methods: Twenty subjects were investigated in this study, consisting of 10 patients with clinical diagnosis of RRMS and 10 controls with similar gender and age to the group with the disease. The three tests that comprise the MSFC were used for the evaluation of gait, upper limb motor function and cognition (memory and processing speed. Student's t-test was used to assess data with normal distribution and data with skewed distribution were evaluated using the Mann-Whitney test. Results: The results showed that the patients with RRMS took longer to perform the locomotion test (6.91 ± 2.35 compared to the control group (5.16 ± 1.28. The MS group (22.06 ± 5.44 also showed greater difficulty in performing a task with the dominant upper limb compared to the healthy subjects (17.79 ± 2.96. No statistically significant difference was found between the groups in the performance of cognitive tasks (p = .65. Conclusion: The use of the MSFC tests proved valuable for measuring possible motor and cognitive impairments in patients with RRMS. Thus, it is suggested that this scale is adopted in clinical practice, improving therapies for the treatment of MS patients and thereby providing them a better quality of life.

  5. Testing a Model of Functional Impairment in Telephone Crisis Support Workers.

    Science.gov (United States)

    Kitchingman, Taneile A; Wilson, Coralie J; Caputi, Peter; Wilson, Ian; Woodward, Alan

    2017-11-01

    It is well known that helping professionals experience functional impairment related to elevated symptoms of psychological distress as a result of frequent empathic engagement with distressed others. Whether telephone crisis support workers are impacted in a similar way is not currently reported in the literature. The purpose of this study was to test a hypothesized model of factors contributing to functional impairment in telephone crisis support workers. A national sample of 210 telephone crisis support workers completed an online survey including measures of emotion regulation, symptoms of general psychological distress and suicidal ideation, intentions to seek help for symptoms, and functional impairment. Structural equation modeling was used to test the fit of the data to the hypothesized model. Goodness-of-fit indices were adequate and supported the interactive effects of emotion regulation, general psychological distress, suicidal ideation, and intentions to seek help for ideation on functional impairment. These results warrant the deliberate management of telephone crisis support workers' impairment through service selection, training, supervision, and professional development strategies. Future research replicating and extending this model will further inform the modification and/or development of strategies to optimize telephone crisis support workers' well-being and delivery of support to callers.

  6. Abnormal ventilation scans in middle-aged smokers. Comparison with tests of overall lung function

    International Nuclear Information System (INIS)

    Barter, S.J.; Cunningham, D.A.; Lavender, J.P.; Gibellino, F.; Connellan, S.J.; Pride, N.B.

    1985-01-01

    The uniformity of regional ventilation during tidal breathing has been assessed using continuous inhalation of krypton-81m in 43 male, lifelong nonsmokers and 46 male, current cigarette smokers (mean daily consumption 24.1 cigarettes/day) between 44 and 61 yr of age and with mild or no respiratory symptoms. All subjects had normal chest radiographs. The results of the ventilation scans were compared with tests of overall lung function (spirometry, maximal expiratory flow-volume curves, and single-breath N2 test). Diffuse abnormalities of the ventilation scan were found in 19 (41%) of the 46 smokers but in none of the nonsmokers. Focal abnormalities were found in 7 smokers and 3 nonsmokers. Smokers showed the expected abnormalities in overall lung function (reduced FEV1 and VC, increased single-breath N2 slope, and closing volume), but in individual smokers there was only a weak relation between the severity of abnormality of overall lung function and an abnormal ventilation scan. Abnormal scans could be found when overall lung function was normal and were not invariably found when significant abnormalities in FEV1/VC or N2 slope were present. There was no relation between the presence of chronic expectoration and an abnormal scan. The prognostic significance of an abnormal ventilation scan in such smokers remains to be established

  7. Acceptance criteria for reprocessed AcuNav catheters: comparison between functionality testing and clinical image assessment.

    Science.gov (United States)

    Bank, Alan J; Berry, James M; Wilson, Robert F; Lester, Bruce R

    2009-03-01

    The AcuNav-catheter is a vector-phased array ultrasound catheter that has shown great utility for both diagnosis and electrophysiological interventions. To test the feasibility of limited catheter reuse and to ensure that reprocessed catheters would produce acceptable clinical images, the present study compared the 2-D and Doppler image quality, as determined by clinical assessment, with the catheter's functional status as determined by the FirstCall 2000 transducer tester. Reprocessed catheters from four functional categories, two acceptable and two unacceptable, were used to collect images, 2-D and Doppler, from a porcine heart. The images were blinded and then rated by clinical evaluation. The study found that catheter images from all functional categories were found to be clinically acceptable except for those from the lowest unacceptable category. In addition, examination of tip deflection characteristics showed no significant difference between new and reprocessed catheters. We conclude that reprocessed AcuNav catheters that pass functional tests are able to produce clinical images, 2-D and Doppler, which are equivalent to their new counterparts.

  8. Differential Item Functioning in While-Listening Performance Tests: The Case of the International English Language Testing System (IELTS) Listening Module

    Science.gov (United States)

    Aryadoust, Vahid

    2012-01-01

    This article investigates a version of the International English Language Testing System (IELTS) listening test for evidence of differential item functioning (DIF) based on gender, nationality, age, and degree of previous exposure to the test. Overall, the listening construct was found to be underrepresented, which is probably an important cause…

  9. Test Functions for Three-Dimensional Control-Volume Mixed Finite-Element Methods on Irregular Grids

    National Research Council Canada - National Science Library

    Naff, R. L; Russell, T. F; Wilson, J. D

    2000-01-01

    .... For control-volume mixed finite-element methods, vector shape functions are used to approximate the distribution of velocities across cells and vector test functions are used to minimize the error...

  10. Cornea stress test--evaluation of corneal endothelial function in vivo by contact lens induced stress

    Directory of Open Access Journals (Sweden)

    Saini Jagjit

    1997-01-01

    Full Text Available Reliable and valid assessment of corneal endothelial function is a critical input for diagnosing, prognosticating and monitoring progression of disorders affecting corneal endothelium. In 123 eyes, corneal endothelial function was assessed employing data from the corneal hydration recovery dynamics. Serial pachometric readings were recorded on Haag-Striet pachometer with Mishima-Hedbys modification before and after two hours of thick soft contact lens wear. Percentage Recovery Per Hour (PRPH was derived from raw data as an index of endothelial function. Assessed PRPH in pseudophakic corneal oedema and Fuchs′ endothelial dystrophy eyes (35.9 +/- 9.8% was significantly lower than normal controls (61.9 +/- 10.5%. On employing receiver operation characteristics curve analysis the tested results demonstrated high sensitivity (87% and specificity (92% for detection of low endothelial function at PRPH cut off of 47.5%. Using this PRPH cut off, 80% of Fuchs′ endothelial dystrophy and 93.3% of pseudophakic corneal oedema eyes could be demonstrated to have low endothelial function. A total of 66.7% of diabetic eyes also demonstrated PRPH of lower than 47.5%. Clear corneal grafts demonstrated PRPH values of 24.6% to 73.0%. Of 6 corneal grafts that demonstrated initial PRPH of lower than 47.5%, 4 failed within 4 to 6 months. Our data demonstrated high sensitivity and specificity of this corneal stress test. PRPH index was useful in quantifying endothelial function in clinical disorders including diabetes mellitus. The index PRPH was demonstrated to be useful in monitoring and prognosticating outcome of corneal grafts.

  11. Toxicological comments to the discussion about REACH.

    Science.gov (United States)

    Greim, Helmut; Arand, Michael; Autrup, Herman; Bolt, Hermann M; Bridges, James; Dybing, Erik; Glomot, Rémi; Foa, Vito; Schulte-Hermann, Rolf

    2006-03-01

    It is the ultimate goal of the intended REACH process (Registration, Evaluation and Authorization of Chemicals) of the European Union to identify substances of hazardous properties and to evaluate the risks of human and environmental exposure. During the last few months there has been a controversial discussion as to what extent in vitro studies and consideration of structure activity relationship provide sufficient information to waive repeated exposure studies. Industry as well as certain regulatory agencies or NGOs support this approach and propose that repeated dose studies may only be required beyond 100 t/a. From a toxicological point of view it has to be stressed that this discussion primarily considers the cost reduction and protection of animals, whereas protection of human health and the environment are secondary. In vitro studies only allow identification of specific hazardous properties which can be detected by the specific test system. Moreover, appropriate information on the dose response of adverse effects, identification of thresholds and NOELs that are essential for risk characterization cannot be obtained from these studies. Consequently, identification of all relevant hazardous properties and endpoints of adverse effects can only be determined in the intact animal by repeated dose studies such as 28-day or 90-day studies. In the absence of such information the hazard identification is incomplete and there is no basis for appropriate risk assessment of human exposure. Thus, any waiving of repeated dose studies in animals bears the probability of unforeseen effects in case of acute or continuous human exposure. From this the undersigning European Toxicologists conclude: 1. The intention of REACH is to identify hazardous properties in order that a reliable risk assessment can be made and measures taken to deal with chemicals posing a significant risk. 2. The recent debate has centered on ways in which the well established in vivo methods for risk

  12. Scintigraphic test of the vitality and functional fitness of organs conserved for transplantation

    International Nuclear Information System (INIS)

    Bozduganov, A.; Marinov, V.

    1976-01-01

    Having reviewed critically present-day methods of testing the vitality of isolated perfused organs, the authors propose their own. It is founded in the principles of colour scintigraphy after introduction of short-lived nuclides. The method was applied in testing 57 isolated preserved organs (5 kidneys, 12 livers, 5 hearts and 4 spleens from dogs; 2 kidneys and 27 livers from rabbits; 1 kidney and 1 liver from young pigs). Moreover, compararive scintigraphic and biochemical investigations were conducted on 2 dogs and 4 young pigs (A. Bozduganov, E. Simeonov, N. Bogdanova). The techniques of isolation and perfusion of the organ have been given a detailed description. Sup(113m)In was used as tracer. Areas of radioactivity deposits were visualized more or less intensely, depending on the degree of vitality and functional fitness still present actually; else, blanks were seen. Orthotransplantation and heterotransplantation with subsequent scintigraphic examination in vivo served, in scattered instances, the purpose of confirming or of rejecting ambiguous vitality findings in preserved organs. Advantages of the method are a general and specified evaluation of the organ in all of its areas; anatomical integrity of the object under test; applicability to various organs; possibility of conducting dynamic tests; accurate reproduction of vitality and functional findings, etc

  13. Embodiment in tests of cognitive functioning: A study of an interpreter-mediated dementia evaluation.

    Science.gov (United States)

    Majlesi, Ali Reza; Plejert, Charlotta

    2018-02-01

    This study explores how manners of mediation, and the use of embodiment in interpreter-mediated conversation have an impact on tests of cognitive functioning in a dementia evaluation. By a detailed analysis of video recordings, we show how participants-an occupational therapist, an interpreter, and a patient-use embodied practices to make the tasks of a test of cognitive functioning intelligible, and how participants collaboratively put the instructions of the tasks into practice. We demonstrate that both instructions and instructed actions-and the whole procedure of accomplishing the tasks-are shaped co-operatively by embodied practices of all three participants involved in the test situation. Consequently, the accomplishment of the tasks should be viewed as the outcome of a collaborative achievement of instructed actions, rather than an individual product. The result of the study calls attention to issues concerning interpretations of, and the reliability of interpreter-mediated tests and their bearings for diagnostic procedures in dementia evaluations.

  14. [Effects of education and strength training on functional tests among older people with osteoarthritis].

    Science.gov (United States)

    Jiménez S, Christian Edgardo; Fernández G, Rubén; Zurita O, Félix; Linares G, Daniel; Farías M, Ariel

    2014-04-01

    Hip and knee osteoarthritis are important causes of pain and disability among older people. Education and strength training can alleviate symptoms and avoid functional deterioration. To assess muscle strength, fall risk and quality of life of older people with osteoarthritis and the effects of physiotherapy education and strength training on these variables. Thirty participants aged 78 ± 5 years (63% women) were randomly assigned to receive physiotherapy (Controls), physiotherapy plus education (Group 1) and physiotherapy plus strength training (group 2). At baseline and after 16 weeks of intervention, patients were evaluated with the Senior Fitness Test, Timed Up and Go and Quality of Life score short form (SF-36). During the intervention period, Senior Fitness Test and Timed Up and Go scores improved in all groups and SF-36 did not change. The improvement in Senior Fitness Test and Timed Up and Go was more marked in Groups 1 and 2 than in the control group. Education and strength training improve functional tests among older people with osteoarthritis.

  15. Intensity response function of the photopic negative response (PhNR): effect of age and test-retest reliability.

    Science.gov (United States)

    Joshi, Nabin R; Ly, Emma; Viswanathan, Suresh

    2017-08-01

    To assess the effect of age and test-retest reliability of the intensity response function of the full-field photopic negative response (PhNR) in normal healthy human subjects. Full-field electroretinograms (ERGs) were recorded from one eye of 45 subjects, and 39 of these subjects were tested on two separate days with a Diagnosys Espion System (Lowell, MA, USA). The visual stimuli consisted of brief (test-retest reliability was assessed with the Wilcoxon signed-rank test and Bland-Altman analysis. Holm's correction was applied to account for multiple comparisons. V max of BT was significantly smaller than that of PT and b-wave, and the V max of PT and b-wave was not significantly different from each other. The slope parameter n was smallest for BT and the largest for b-wave and the difference between the slopes of all three measures were statistically significant. Small differences observed in the mean values of K for the different measures did not reach statistical significance. The Wilcoxon signed-rank test indicated no significant differences between the two test visits for any of the Naka-Rushton parameters for the three ERG measures, and the Bland-Altman plots indicated that the mean difference between test and retest measurements of the different fit parameters was close to zero and within 6% of the average of the test and retest values of the respective parameters for all three ERG measurements, indicating minimal bias. While the coefficient of reliability (COR, defined as 1.96 times the standard deviation of the test and retest difference) of each fit parameter was more or less comparable across the three ERG measurements, the %COR (COR normalized to the mean test and retest measures) was generally larger for BT compared to both PT and b-wave for each fit parameter. The Naka-Rushton fit parameters did not show statistically significant changes with age for any of the ERG measures when corrections were applied for multiple comparisons. However, the V max of

  16. Sport-specific endurance plank test for evaluation of global core muscle function.

    Science.gov (United States)

    Tong, Tom K; Wu, Shing; Nie, Jinlei

    2014-02-01

    To examine the validity and reliability of a sports-specific endurance plank test for the evaluation of global core muscle function. Repeated-measures study. Laboratory environment. Twenty-eight male and eight female young athletes. Surface electromyography (sEMG) of selected trunk flexors and extensors, and an intervention of pre-fatigue core workout were applied for test validation. Intraclass correlation coefficient (ICC), coefficient of variation (CV), and the measurement bias ratio */÷ ratio limits of agreement (LOA) were calculated to assess reliability and measurement error. Test validity was shown by the sEMG of selected core muscles, which indicated >50% increase in muscle activation during the test; and the definite discrimination of the ∼30% reduction in global core muscle endurance subsequent to a pre-fatigue core workout. For test-retest reliability, when the first attempt of three repeated trials was considered as familiarisation, the ICC was 0.99 (95% CI: 0.98-0.99), CV was 2.0 ± 1.56% and the measurement bias ratio */÷ ratio LOA was 0.99 */÷ 1.07. The findings suggest that the sport-specific endurance plank test is a valid, reliable and practical method for assessing global core muscle endurance in athletes given that at least one familiarisation trial takes place prior to measurement. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Peer Support for the Hardly Reached: A Systematic Review.

    Science.gov (United States)

    Sokol, Rebeccah; Fisher, Edwin

    2016-07-01

    Health disparities are aggravated when prevention and care initiatives fail to reach those they are intended to help. Groups can be classified as hardly reached according to a variety of circumstances that fall into 3 domains: individual (e.g., psychological factors), demographic (e.g., socioeconomic status), and cultural-environmental (e.g., social network). Several reports have indicated that peer support is an effective means of reaching hardly reached individuals. However, no review has explored peer support effectiveness in relation to the circumstances associated with being hardly reached or across diverse health problems. To conduct a systematic review assessing the reach and effectiveness of peer support among hardly reached individuals, as well as peer support strategies used. Three systematic searches conducted in PubMed identified studies that evaluated peer support programs among hardly reached individuals. In aggregate, the searches covered articles published from 2000 to 2015. Eligible interventions provided ongoing support for complex health behaviors, including prioritization of hardly reached populations, assistance in applying behavior change plans, and social-emotional support directed toward disease management or quality of life. Studies were excluded if they addressed temporally isolated behaviors, were limited to protocol group classes, included peer support as the dependent variable, did not include statistical tests of significance, or incorporated comparison conditions that provided appreciable social support. We abstracted data regarding the primary health topic, categorizations of hardly reached groups, program reach, outcomes, and strategies employed. We conducted a 2-sample t test to determine whether reported strategies were related to reach. Forty-seven studies met our inclusion criteria, and these studies represented each of the 3 domains of circumstances assessed (individual, demographic, and cultural-environmental). Interventions

  18. West Valley Demonstration Project vitrification process equipment Functional and Checkout Testing of Systems (FACTS)

    International Nuclear Information System (INIS)

    Carl, D.E.; Paul, J.; Foran, J.M.; Brooks, R.

    1990-01-01

    The Vitrification Facility (VF) at the West Valley Demonstration Project was designed to convert stored radioactive waste into a stable glass for disposal in a federal repository. The Functional and Checkout Testing of Systems (FACTS) program was conducted from 1984 to 1989. During this time new equipment and processes were developed, installed, and implemented. Thirty-seven FACTS tests were conducted, and approximately 150,000 kg of glass were made by using nonradioactive materials to simulate the radioactive waste. By contrast, the planned radioactive operation is expected to produce approximately 500,000 kg of glass. The FACTS program demonstrated the effectiveness of equipment and procedures in the vitrification system, and the ability of the VF to produce quality glass on schedule. FACTS testing also provided data to validate the WVNS waste glass qualification method and verify that the product glass would meet federal repository acceptance requirements. The system was built and performed to standards which would have enabled it to be used in radioactive service. As a result, much of the VF tested, such as the civil construction, feed mixing and holding vessels, and the off-gas scrubber, will be converted for radioactive operation. The melter was still in good condition after being at temperature for fifty-eight of the sixty months of FACTS. However, the melter exceeded its recommended design life and will be replaced with a similar melter. Components that were not designed for remote operation and maintenance will be replaced with remote-use items. The FACTS testing was accomplished with no significant worker injury or environmental releases. During the last FACTS run, the VF processes approximated the remote-handling system that will be used in radioactive operations. Following this run the VF was disassembled for conversion to a radioactive process. Functional and checkout testing of new components will be performed prior to radioactive operation

  19. Object Permanence, Reaching, and Locomotion in Infants Who Are Blind.

    Science.gov (United States)

    Ross, S.; Tobin, M. J.

    1997-01-01

    The literature on the effects of congenital blindness on infants' development of motor functions and concepts of object permanence is reviewed. The article questions the idea that infants must first develop an object concept before sound clues alone will elicit reaching. Possible interventions to redress the effects of congenital blindness on…

  20. New kidney physiopathology concepts acquired from a quantitative kidney function examination: the 197Hg uptake test

    International Nuclear Information System (INIS)

    Raynaud, C.; Ricard, S.; Knipper, M.