Sample records for functional immunoassay technology

  1. Streptavidin-functionalized capillary immune microreactor for highly efficient chemiluminescent immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Yang Zhanjun [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); College of Chemistry and Engineering, Yangzhou University, 88 South University Avenue, Yangzhou 225002 (China); Zong Chen [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Ju Huangxian, E-mail: hxju@nju.edu.cn [State Key Laboratory of Analytical Chemistry for Life Science, Department of Chemistry, Nanjing University, Nanjing 210093 (China); Yan Feng, E-mail: yanfeng2007@sohu.com [Jiangsu Institute of Cancer Prevention and Cure, Nanjing 210009 (China)

    2011-11-07

    Highlights: {yields} A novel capillary immune microreactor was proposed for highly efficient flow-through chemiluminescent immunoassay. {yields} The microreactor was prepared by functionalizing capillary inner wall with streptavidin for capture of biotinylated antibody. {yields} The proposed immunoassay method showed wide dynamic range, good reproducibility, stability and practicality. {yields} The microreactor was low-cost and disposable, and possessed several advantages over the conventional immunoreactors. - Abstract: A streptavidin functionalized capillary immune microreactor was designed for highly efficient flow-through chemiluminescent (CL) immunoassay. The functionalized capillary could be used as both a support for highly efficient immobilization of antibody and a flow cell for flow-through immunoassay. The functionalized inner wall and the capture process were characterized using scanning electron microscopy. Compared to conventional packed tube or thin-layer cell immunoreactor, the proposed microreactor showed remarkable properties such as lower cost, simpler fabrication, better practicality and wider dynamic range for fast CL immunoassay with good reproducibility and stability. Using {alpha}-fetoprotein as model analyte, the highly efficient CL flow-through immunoassay system showed a linear range of 3 orders of magnitude from 0.5 to 200 ng mL{sup -1} and a low detection limit of 0.1 ng mL{sup -1}. The capillary immune microreactor could make up the shortcoming of conventional CL immunoreactors and provided a promising alternative for highly efficient flow-injection immunoassay.

  2. Materials for Microfluidic Immunoassays: A Review.

    Science.gov (United States)

    Mou, Lei; Jiang, Xingyu

    2017-08-01

    Conventional immunoassays suffer from at least one of these following limitations: long processing time, high costs, poor user-friendliness, technical complexity, poor sensitivity and specificity. Microfluidics, a technology characterized by the engineered manipulation of fluids in channels with characteristic lengthscale of tens of micrometers, has shown considerable promise for improving immunoassays that could overcome these limitations in medical diagnostics and biology research. The combination of microfluidics and immunoassay can detect biomarkers with faster assay time, reduced volumes of reagents, lower power requirements, and higher levels of integration and automation compared to traditional approaches. This review focuses on the materials-related aspects of the recent advances in microfluidics-based immunoassays for point-of-care (POC) diagnostics of biomarkers. We compare the materials for microfluidic chips fabrication in five aspects: fabrication, integration, function, modification and cost, and describe their advantages and drawbacks. In addition, we review materials for modifying antibodies to improve the performance of the reaction of immunoassay. We also review the state of the art in microfluidic immunoassays POC platforms, from the laboratory to routine clinical practice, and also commercial products in the market. Finally, we discuss the current challenges and future developments in microfluidic immunoassays. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Can LC and LC-MS ever replace immunoassays?

    Directory of Open Access Journals (Sweden)

    Timothy G. Cross

    2016-10-01

    Full Text Available Immunoassays have been the technology of choice for the analysis of biomolecules for many decades across a wide range of applications in research, diagnostics and infectious disease monitoring. There are good reasons for the wide adoption of immunoassays but even such a well established and characterised technique has limitations and as such investigators are looking at alternative technologies. One such alternative is liquid chromatography (LC and, more specifically, liquid chromatography coupled with mass spectrometry (LC-MS. This article will review both immunoassay and LC and LC-MS technologies and methodologies and discuss the advantages and limitations of both approaches. In addition, the next developments that will need to occur before there is widespread adoption of LC and LC-MS technology preferentially over immunoassays will be examined.

  4. Variance function estimation for immunoassays

    International Nuclear Information System (INIS)

    Raab, G.M.; Thompson, R.; McKenzie, I.

    1980-01-01

    A computer program is described which implements a recently described, modified likelihood method of determining an appropriate weighting function to use when fitting immunoassay dose-response curves. The relationship between the variance of the response and its mean value is assumed to have an exponential form, and the best fit to this model is determined from the within-set variability of many small sets of repeated measurements. The program estimates the parameter of the exponential function with its estimated standard error, and tests the fit of the experimental data to the proposed model. Output options include a list of the actual and fitted standard deviation of the set of responses, a plot of actual and fitted standard deviation against the mean response, and an ordered list of the 10 sets of data with the largest ratios of actual to fitted standard deviation. The program has been designed for a laboratory user without computing or statistical expertise. The test-of-fit has proved valuable for identifying outlying responses, which may be excluded from further analysis by being set to negative values in the input file. (Auth.)

  5. DEMONSTRATION BULLETIN: PCP IMMUNOASSAY TECHNOLOGIES - PENTA RISC BY ENSYS INC., PENTA RAPID BY OHMICRON CORP., ENVIROGARD BY MILLIPORE

    Science.gov (United States)

    The objectives of this demonstration were to test these field screening technologies for accuracy and precision in detecting Pentachlorophenol (PCP) levels in soil and water by comparing their results with those of a confirmatory laboratory. The three immunoassay technologies ...

  6. Novel immunoassay formats for integrated microfluidic circuits: diffusion immunoassays (DIA)

    Science.gov (United States)

    Weigl, Bernhard H.; Hatch, Anson; Kamholz, Andrew E.; Yager, Paul

    2000-03-01

    Novel designs of integrated fluidic microchips allow separations, chemical reactions, and calibration-free analytical measurements to be performed directly in very small quantities of complex samples such as whole blood and contaminated environmental samples. This technology lends itself to applications such as clinical diagnostics, including tumor marker screening, and environmental sensing in remote locations. Lab-on-a-Chip based systems offer many *advantages over traditional analytical devices: They consume extremely low volumes of both samples and reagents. Each chip is inexpensive and small. The sampling-to-result time is extremely short. They perform all analytical functions, including sampling, sample pretreatment, separation, dilution, and mixing steps, chemical reactions, and detection in an integrated microfluidic circuit. Lab-on-a-Chip systems enable the design of small, portable, rugged, low-cost, easy to use, yet extremely versatile and capable diagnostic instruments. In addition, fluids flowing in microchannels exhibit unique characteristics ('microfluidics'), which allow the design of analytical devices and assay formats that would not function on a macroscale. Existing Lab-on-a-chip technologies work very well for highly predictable and homogeneous samples common in genetic testing and drug discovery processes. One of the biggest challenges for current Labs-on-a-chip, however, is to perform analysis in the presence of the complexity and heterogeneity of actual samples such as whole blood or contaminated environmental samples. Micronics has developed a variety of Lab-on-a-Chip assays that can overcome those shortcomings. We will now present various types of novel Lab- on-a-Chip-based immunoassays, including the so-called Diffusion Immunoassays (DIA) that are based on the competitive laminar diffusion of analyte molecules and tracer molecules into a region of the chip containing antibodies that target the analyte molecules. Advantages of this

  7. The right environment for the immunoassay

    International Nuclear Information System (INIS)

    Emon, J.M. Van; Gerlach, C.L.

    1995-01-01

    For the US Environmental Protection Agency (EPA), the first in-house research effort began in 1987, when results of an early immunoassay field study verified the technology's potential for environmental applications. Looking at the fundamental features of immunochemical reactions from the clinical laboratories, analytical chemists realized the potential value of these methods for hazardous waste site characterization and pesticide monitoring. Immunoassays rely on the interaction between an antibody and a target analyte. For environmental purposes, enzyme immunoassays are generally used. After the target analyte binds to the antibody, an enzymatic reaction yields a colorimetric change. This change, read visually or by a spectrophotometer, indicates the concentration of the target analyte. Promising results with assays for compounds (such as paraquat and pentachlorophenol) and compound groups (such as total petroleum hydrocarbons and polychlorinated biphenyls) spurred interest among various entrepreneurs. The first target market for immunoassays was environmental engineers and field crews who needed quick answers on-site to determine the direction of further remediation efforts

  8. Rapid micromotor-based naked-eye immunoassay.

    Science.gov (United States)

    de Ávila, Berta Esteban-Fernández; Zhao, Mingjiao; Campuzano, Susana; Ricci, Francesco; Pingarrón, José M; Mascini, Marcello; Wang, Joseph

    2017-05-15

    A dynamic micromotor-based immunoassay, exemplified by cortisol detection, based on the use of tubular micromotors functionalized with a specific antibody is described. The use of antibody-functionalized micromotors offers huge acceleration of both direct and competitive cortisol immunoassays, along with greatly enhanced sensitivity of direct and competitive immunoassays. The dramatically improved speed and sensitivity reflect the greatly increased likelihood of antibody-cortisol contacts and fluid mixing associated with the dynamic movement of these microtube motors and corresponding bubble generation that lead to a highly efficient and rapid recognition process. Rapid naked-eye detection of cortisol in the sample is achieved in connection to use of horseradish peroxidase (HRP) tag and TMB/H 2 O 2 system. Key parameters of the competitive immunoassay (e.g., incubation time and reaction volume) were optimized. This fast visual micromotor-based sensing approach enables "on the move" specific detection of the target cortisol down to 0.1μgmL -1 in just 2min, using ultrasmall (50µL) sample volumes. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Trends in interfacial design for surface plasmon resonance based immunoassays

    International Nuclear Information System (INIS)

    Shankaran, Dhesingh Ravi; Miura, Norio

    2007-01-01

    Immunosensors based on surface plasmon resonance (SPR) have become a promising tool in sensor technology for biomedical, food, environmental, industrial and homeland security applications. SPR is a surface sensitive optical technique, suitable for real-time and label-free analysis of biorecognition events at functional transducer surfaces. Fabrication of highly active and robust sensing surfaces is an important part in immunoassays because the quality, quantity, chemistry and topography of the interfacial biomembranes play a major role in immunosensor performance. Eventually, a variety of immobilization methods such as physical adsorption, covalent coupling, Langmuir-Blodgett film, polymer thin film, self-assembly, sol-gel, etc, have been introduced over the years for the immobilization of biomolecules (antibody or antigen) on the transducer surfaces. The selection of an immobilization method for an immunoassay is governed by several factors such as nature and stability of the biomolecules, target analyte, application, detection principle, mode of signal transduction, matrix complexity, etc. This paper provides an overview of the various surface modification methods for SPR based immunosensor fabrication. The preparation, structure and application of different functional interfacial surfaces have been discussed along with a brief introduction to the SPR technology, biomolecules and detection principles. (review article)

  10. Trends in interfacial design for surface plasmon resonance based immunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Shankaran, Dhesingh Ravi [Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga-shi, Fukuoka, 816-8580 (Japan); Miura, Norio [Art, Science and Technology Center for Cooperative Research, Kyushu University, Kasuga-shi, Fukuoka, 816-8580 (Japan)

    2007-12-07

    Immunosensors based on surface plasmon resonance (SPR) have become a promising tool in sensor technology for biomedical, food, environmental, industrial and homeland security applications. SPR is a surface sensitive optical technique, suitable for real-time and label-free analysis of biorecognition events at functional transducer surfaces. Fabrication of highly active and robust sensing surfaces is an important part in immunoassays because the quality, quantity, chemistry and topography of the interfacial biomembranes play a major role in immunosensor performance. Eventually, a variety of immobilization methods such as physical adsorption, covalent coupling, Langmuir-Blodgett film, polymer thin film, self-assembly, sol-gel, etc, have been introduced over the years for the immobilization of biomolecules (antibody or antigen) on the transducer surfaces. The selection of an immobilization method for an immunoassay is governed by several factors such as nature and stability of the biomolecules, target analyte, application, detection principle, mode of signal transduction, matrix complexity, etc. This paper provides an overview of the various surface modification methods for SPR based immunosensor fabrication. The preparation, structure and application of different functional interfacial surfaces have been discussed along with a brief introduction to the SPR technology, biomolecules and detection principles. (review article)

  11. Status of immunoassay as an analytical tool in environmental investigations

    International Nuclear Information System (INIS)

    Van Emon, J.M.

    2000-01-01

    Immunoassay methods were initially applied in clinical situations where their sensitivity and selectivity were utilized for diagnostic purposes. In the 1970s, pesticide chemists realized the potential benefits of immunoassay methods for compounds difficult to analyze by gas chromatography. This transition of the technology has extended to the analysis of soil, water, food and other matrices of environmental and human exposure significance particularly for compounds difficult to analyze by chromatographic methods. The utility of radioimmunoassays and enzyme immunoassays for environmental investigations was recognized in the 1980s by the U.S. Environmental Protection Agency (U.S. EPA) with the initiation of an immunoassay development programme. The U.S. Department of Agriculture (USDA) and the U.S. Food and Drug Administration (PDA) have investigated immunoassays for the detection of residues in food both from an inspection and a contamination prevention perspective. Environmental immunoassays are providing rapid screening information as well as quantitative information to fulfill rigorous data quality objectives for monitoring programmes

  12. Hydrogel nanoparticle based immunoassay

    Science.gov (United States)

    Liotta, Lance A; Luchini, Alessandra; Petricoin, Emanuel F; Espina, Virginia

    2015-04-21

    An immunoassay device incorporating porous polymeric capture nanoparticles within either the sample collection vessel or pre-impregnated into a porous substratum within fluid flow path of the analytical device is presented. This incorporation of capture particles within the immunoassay device improves sensitivity while removing the requirement for pre-processing of samples prior to loading the immunoassay device. A preferred embodiment is coreshell bait containing capture nanoparticles which perform three functions in one step, in solution: a) molecular size sieving, b) target analyte sequestration and concentration, and c) protection from degradation. The polymeric matrix of the capture particles may be made of co-polymeric materials having a structural monomer and an affinity monomer, the affinity monomer having properties that attract the analyte to the capture particle. This device is useful for point of care diagnostic assays for biomedical applications and as field deployable assays for environmental, pathogen and chemical or biological threat identification.

  13. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    Science.gov (United States)

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  14. A competitive immunoassay for sensitive detection of small molecules chloramphenicol based on luminol functionalized silver nanoprobe.

    Science.gov (United States)

    Yu, Xiuxia; He, Yi; Jiang, Jie; Cui, Hua

    2014-02-17

    Chloramphenicol (CHL) as a broad-spectrum antibiotic has a broad action spectrum against Gram-positive and Gram-negative bacteria, as well as anaerobes. The use of CHL is strictly restricted in poultry because of its toxic effect. However, CHL is still illegally used in animal farming because of its accessibility and low cost. Therefore, sensitive methods are highly desired for the determination of CHL in foodstuffs. The immunoassays based on labeling as an important tool have been reported for the detection of CHL residues in food-producing animals. However, most of the labeling procedures require multi-step reactions and purifications and thus they are complicated and time-consuming. Recently, in our previous work, luminol functionalized silver nanoparticles have been successfully synthesized, which exhibits higher CL efficiency than luminol functionalized gold nanoparticles. In this work, the new luminol functionalized silver nanoparticles have been used for the labeling of small molecules CHL for the first time and a competitive chemiluminescent immunoassay has been developed for the detection of CHL. Owing to the amplification of silver nanoparticles, high sensitivity for CHL could be achieved with a low detection limit of 7.6×10(-9) g mL(-1) and a wide linear dynamic range of 1.0×10(-8)-1.0×10(-6) g mL(-1). This method has also been successfully applied to determine CHL in milk and honey samples with a good recoveries (92% and 102%, 99% and 107% respectively), indicating that the method is feasible for the determination of CHL in real milk and honey samples. The labeling procedure is simple, convenient and fast, superior to previously reported labeling procedures. The immunoassay is also simple, fast, sensitive and selective. It is of application potential for the determination of CHL in foodstuffs. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Simple patterned nanofiber scaffolds and its enhanced performance in immunoassay.

    Directory of Open Access Journals (Sweden)

    Jing Wang

    Full Text Available Cancer has become the leading cause of death worldwide; early diagnosis and treatment of cancers is critical for the survival of the patients. The concentration of cancer markers in easy-to-access biological fluids can provide great assistance in screening for occult primary cancers, distinguishing malignant from benign findings, determining prognosis and prediction for cancer patients. The multiplex detection technology of a panel of cancer markers can greatly increase the accuracy of disease diagnosis. Herein, we briefly fabricate a high-throughput micro-immunoassay based on the electrospun polystyrene (PS substrates to improve detection sensitivity. The immunoassay was evaluated by analyzing three different cancer biomarkers (AFP, CEA, VEGF. For AFP, CEA, VEGF immunofluorescence assay, the LOD of assay conducted on electrospun PS substrates before or after plasma and the conventional PS substrates were 0.42, 0.10, 1.12 ng/mL, 0.57, 0.09, 1.24 ng/mL, and 159.75, 26.19, 385.59 pg/mL, respectively (P < 0.05. Due to the high porosity and large surface area-to-volume ratio which is the foremost merit of nanostructures, and the plasma treatment which make the hydrophobic PS nanofibers hydropholic, the nanofibers substrates showed sufficient retention of immunoassay functionality and high potential for capture molecules immobilization. Consequently, the immunofluorescence assay conducted on electrospun PS substrates could significantly enhance the sensitivity and limits of detection.

  16. Functionalization of single-walled carbon nanotubes with protein by click chemistry as sensing platform for sensitized electrochemical immunoassay

    International Nuclear Information System (INIS)

    Qi Honglan; Ling Chen; Huang Ru; Qiu Xiaoying; Shangguan Li; Gao Qiang; Zhang Chengxiao

    2012-01-01

    Highlights: ► Single-walled carbon nanotubes were functionalized with protein by click chemistry. ► The SWNTs conjugated with protein showed excellent dispersion in water and kept good bioacitvity. ► A competitive electrochemical immunoassay for the determination of anti-IgG was developed with high sensitivity and good stability. - Abstract: The application of the Cu(I)-catalyzed [3 + 2] Huisgen cycloaddition to the functionalization of single-walled carbon nanotubes (SWNTs) with the protein and the use of the artificial SWNTs as a sensing platform for sensitive immunoassay were reported. Covalent functionalization of azide decorated SWNTs with alkyne modified protein was firstly accomplished by the Cu(I)-catalyzed [3 + 2] Huisgen cycloaddition. FT-IR spectroscopy, Raman spectroscopy, X-ray photoelectron spectroscopy, scanning electron microscopy and transmission electron micrograph were used to characterize the protein-functionalized SWNTs. It was found that the SWNTs conjugated with the proteins showed excellent dispersion in water and kept good bioacitivity when immunoglobulin (IgG) and horseradish peroxidase (HRP) were chosen as model proteins. As a proof-of-concept, IgG-functionalized SWNTs were immobilized onto the surface of a glassy carbon electrode by simple casting method as immunosensing platform and a sensitive competitive electrochemical immunoassay was developed for the determination of anti-immunoglobulin (anti-IgG) using HRP as enzyme label. The fabrication of the immunosensor were characterized by cyclic voltammetry and electrochemical impedance spectroscopy with the redox probe [Fe(CN) 6 ] 3−/4− . The SWNTs as immobilization platform showed better sensitizing effect, a detection limit of 30 pg mL −1 (S/N = 3) was obtained for anti-IgG. The proposed strategy provided a stable immobilization method and sensitized recognition platform for analytes. This work demonstrated that the click coupling of SWNTs with protein was an effective

  17. Immunoassays in Biotechnology

    Science.gov (United States)

    Immunoassays have broad applications for a wide variety of important biological compounds and environmental contaminants. Immunoassays can detect the presence of an antigen in the human body, a pollutant in the environment, or a critical antibody in a patient’s serum to develop a...

  18. Interference in immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Interfering factors are evident in both limited reagent (radioimmunoassay) and excess reagent (immunometric assay) technologies and should be suspected whenever there is a discrepancy between analytical results and clinical findings in the investigation of particular diseases. The overall effect of interference in immunoassay is analytical bias in result, either positive or negative of variable magnitude. The interference maybe caused by a wide spectrum of factors from poor sample collection and handling to physiological factors e.g. lipaemia, heparin treatment, binding protein abnormalities, autoimmunity and drug treatments. The range of interfering factors is extensive and difficult to discuss effectively in a short review

  19. Current status and future developments in radiolabelled immunoassays

    International Nuclear Information System (INIS)

    Edwards, R.

    1998-01-01

    Radioisotopes are used extensively in medical practice and their use in RIA or IRMA usually represent a small proportion of the total. Radiolabelled immunoassays based on 125 I constitute a simple didactic, cost effective and robust technology which is still regarded as the reference method in many clinical applications. The IAEA has implemented many successful programmes using the ''bulk reagent'' approach, involving 68 countries in all the different regions. The main achievements have been in technology transfer with self sufficiency in production for some countries; training of large numbers of staff; quality control and quality assurance schemes; devolution of screening programmes for neonatal congenital hypothryoidism. Alternatives to the use of radioisotopic tracers are constrained by many factors and are often only available in restricted commercial packages. They are often not suitable for technology transfer programmes and often lack any didactic component in addition to a relative high cost. The production of radiolabels using 125 I is both simple and adaptable. In addition expertise in their preparation and purification is widespread even in developing countries. Together with the ease of producing antibodies, the facts have made 125 I-radiolabelled immunoassays ideal for investigative procedures for many research activities (30,31) particularly in the medical context where radioisotopes are commonly used. In conclusion, even a superficial examination of public health statistics for various countries throughout the continents indicates a need for a simple, inexpensive and robust analytical tool. In this light, there is a predicted continuing role for radiolabelled immunoassays. (author)

  20. Comparison of pre-processing methods for multiplex bead-based immunoassays.

    Science.gov (United States)

    Rausch, Tanja K; Schillert, Arne; Ziegler, Andreas; Lüking, Angelika; Zucht, Hans-Dieter; Schulz-Knappe, Peter

    2016-08-11

    High throughput protein expression studies can be performed using bead-based protein immunoassays, such as the Luminex® xMAP® technology. Technical variability is inherent to these experiments and may lead to systematic bias and reduced power. To reduce technical variability, data pre-processing is performed. However, no recommendations exist for the pre-processing of Luminex® xMAP® data. We compared 37 different data pre-processing combinations of transformation and normalization methods in 42 samples on 384 analytes obtained from a multiplex immunoassay based on the Luminex® xMAP® technology. We evaluated the performance of each pre-processing approach with 6 different performance criteria. Three performance criteria were plots. All plots were evaluated by 15 independent and blinded readers. Four different combinations of transformation and normalization methods performed well as pre-processing procedure for this bead-based protein immunoassay. The following combinations of transformation and normalization were suitable for pre-processing Luminex® xMAP® data in this study: weighted Box-Cox followed by quantile or robust spline normalization (rsn), asinh transformation followed by loess normalization and Box-Cox followed by rsn.

  1. Micromotor-based lab-on-chip immunoassays

    Science.gov (United States)

    García, Miguel; Orozco, Jahir; Guix, Maria; Gao, Wei; Sattayasamitsathit, Sirilak; Escarpa, Alberto; Merkoçi, Arben; Wang, Joseph

    2013-01-01

    Here we describe the first example of using self-propelled antibody-functionalized synthetic catalytic microengines for capturing and transporting target proteins between the different reservoirs of a lab-on-a-chip (LOC) device. A new catalytic polymer/Ni/Pt microtube engine, containing carboxy moieties on its mixed poly(3,4-ethylenedioxythiophene) (PEDOT)/COOH-PEDOT polymeric outermost layer, is further functionalized with the antibody receptor to selectively recognize and capture the target protein. The new motor-based microchip immunoassay operations are carried out without any bulk fluid flow, replacing the common washing steps in antibody-based protein bioassays with the active transport of the captured protein throughout the different reservoirs, where each step of the immunoassay takes place. A first microchip format involving an `on-the-fly' double-antibody sandwich assay (DASA) is used for demonstrating the selective capture of the target protein, in the presence of excess of non-target proteins. A secondary antibody tagged with a polymeric-sphere tracer allows the direct visualization of the binding events. In a second approach the immuno-nanomotor captures and transports the microsphere-tagged antigen through a microchannel network. An anti-protein-A modified microengine is finally used to demonstrate the selective capture, transport and convenient label-free optical detection of a Staphylococcus aureus target bacteria (containing proteinA in its cell wall) in the presence of a large excess of non-target (Saccharomyces cerevisiae) cells. The resulting nanomotor-based microchip immunoassay offers considerable potential for diverse applications in clinical diagnostics, environmental and security monitoring fields.Here we describe the first example of using self-propelled antibody-functionalized synthetic catalytic microengines for capturing and transporting target proteins between the different reservoirs of a lab-on-a-chip (LOC) device. A new catalytic

  2. Specificity of immunoassays. Pt. 2

    International Nuclear Information System (INIS)

    Pratt, J.J.; Woldring, M.G.; Boonman, R.; Kittikool, J.

    1979-01-01

    Practical aspects of the measurement of the specificity of immunoassay are reviewed. Antibody heterogeneity in an antiserum makes a pragmatic rather than a theoretical approach necessary. A new method for the measurement of immunoassay specificity is described. This method is based on the errors caused by the cross-reacting antigens and is directly relevant to the validity of results obtained by immunoassay methods. The effect of selectively blocking the least specific antibodies in antisera raised against steroid haptens is tested. The practical consequences of these considerations are tested using steroid radioimmunoassay and enzyme-immunoassay. (orig.) [de

  3. Flotation Immunoassay: Masking the Signal from Free Reporters in Sandwich Immunoassays.

    Science.gov (United States)

    Chen, Hui; Hagström, Anna E V; Kim, Jinsu; Garvey, Gavin; Paterson, Andrew; Ruiz-Ruiz, Federico; Raja, Balakrishnan; Strych, Ulrich; Rito-Palomares, Marco; Kourentzi, Katerina; Conrad, Jacinta C; Atmar, Robert L; Willson, Richard C

    2016-04-14

    In this work, we demonstrate that signal-masking reagents together with appropriate capture antibody carriers can eliminate the washing steps in sandwich immunoassays. A flotation immunoassay (FI) platform was developed with horseradish peroxidase chemiluminescence as the reporter system, the dye Brilliant Blue FCF as the signal-masking reagent, and buoyant silica micro-bubbles as the capture antibody carriers. Only reporters captured on micro-bubbles float above the dye and become visible in an analyte-dependent manner. These FIs are capable of detecting proteins down to attomole levels and as few as 10(6) virus particles. This signal-masking strategy represents a novel approach to simple, sensitive and quantitative immunoassays in both laboratory and point-of-care settings.

  4. Nanogold–polyaniline–nanogold microspheres-functionalized molecular tags for sensitive electrochemical immunoassay of thyroid-stimulating hormone

    International Nuclear Information System (INIS)

    Cui Yuling; Chen Huafeng; Hou Li; Zhang Bing; Liu Bingqian; Chen Guonan; Tang Dianping

    2012-01-01

    Highlights: ► A novel immunosensing strategy was designed for detection of thyroid-stimulating hormone. ► Using nanogold–polyaniline–nanogold microspheres as molecular tags. ► Improvement of electrochemical activity of nanolabels. ► Combination enzyme labels with nanolabels for signal amplification. - Abstract: Methods based on nanomaterial labels have been developed for electrochemical immunosensors and immunoassays, but most involved low sensitivity. Herein a novel class of molecular tags, nanogold–polyaniline–nanogold microspheres (GPGs), was first synthesized and functionalized with horseradish peroxidase-conjugated thyroid-stimulating hormone antibody (HRP-Ab 2 ) for sensitive electrochemical immunoassay of thyroid-stimulating hormone (TSH). X-ray diffraction, confocal Raman spectroscopy, scanning electron microscope and transmission electron microscope were employed to characterize the prepared GPGs. Based on a sandwich-type immunoassay format, the assay was performed in pH 5.0 acetate buffer containing 6.0 mmol L −1 H 2 O 2 by using GPG-labeled HRP-Ab 2 as molecular tags. Compared with pure polyaniline nanospheres and gold nanoparticles alone, the GPG hybrid nanostructures increased the surface area of the nanomaterials, and enhanced the immobilized amount of HRP-Ab 2 . Several labeling protocols comprising HRP-Ab 2 , nanogold particle-labeled HRP-Ab 2 , and polyaniline nanospheres-labeled HRP-Ab 2 , were also investigated for determination of TSH and improved analytical features were obtained by using the GPG-labeled HRP-Ab 2 . With the GPG labeling method, the effects of incubation time and pH of acetate buffer on the current responses of the immunosensors were also studied. The strong attachment of HRP-Ab 2 to the GPGs resulted in a good repeatability and intermediate precision down to 7%. The dynamic concentration range spanned from 0.01 to 20 μIU mL −1 with a detection limit (LOD) of 0.005 μIU mL −1 TSH at the 3s B criterion

  5. BIOTIN INTERFERENCE WITH ROUTINE CLINICAL IMMUNOASSAYS: UNDERSTAND THE CAUSES AND MITIGATE THE RISKS.

    Science.gov (United States)

    Samarasinghe, Shanika; Meah, Farah; Singh, Vinita; Basit, Arshi; Emanuele, Nicholas; Emanuele, Mary Ann; Mazhari, Alaleh; Holmes, Earle W

    2017-08-01

    The objectives of this report are to review the mechanisms of biotin interference with streptavidin/biotin-based immunoassays, identify automated immunoassay systems vulnerable to biotin interference, describe how to estimate and minimize the risk of biotin interference in vulnerable assays, and review the literature pertaining to biotin interference in endocrine function tests. The data in the manufacturer's "Instructions for Use" for each of the methods utilized by seven immunoassay system were evaluated. We also conducted a systematic search of PubMed/MEDLINE for articles containing terms associated with biotin interference. Available original reports and case series were reviewed. Abstracts from recent scientific meetings were also identified and reviewed. The recent, marked, increase in the use of over-the-counter, high-dose biotin supplements has been accompanied by a steady increase in the number of reports of analytical interference by exogenous biotin in the immunoassays used to evaluate endocrine function. Since immunoassay methods of similar design are also used for the diagnosis and management of anemia, malignancies, autoimmune and infectious diseases, cardiac damage, etc., biotin-related analytical interference is a problem that touches every area of internal medicine. It is important for healthcare personnel to become more aware of immunoassay methods that are vulnerable to biotin interference and to consider biotin supplements as potential sources of falsely increased or decreased test results, especially in cases where a lab result does not correlate with the clinical scenario. FDA = U.S. Food & Drug Administration FT3 = free tri-iodothyronine FT4 = free thyroxine IFUs = instructions for use LH = luteinizing hormone PTH = parathyroid hormone SA/B = streptavidin/biotin TFT = thyroid function test TSH = thyroid-stimulating hormone.

  6. A review of promising new immunoassay technology for monitoring forest herbicides

    Science.gov (United States)

    Charles K. McMahon

    1993-01-01

    Rising costs of classical instrumental methods of chemical analysis coupled with an increasing need for environmental monitoring has lead to the development of highly sensitive, low-cost immunochemical methods of analysis for the detection of environmental contaminants. These methods known simply as immunoassays are chemical assays which use antibodies as reagents. A...

  7. Monoclonal antibody-based immunoassays.

    Science.gov (United States)

    Appleby, P; Reischl, U

    1998-01-01

    An immunoassay may be defined as an assay that employs an immunological reagent, usually an antibody, to confer specificity for the ligand being measured. As a corollary to this, the discovery, and subsequent development, of monoclonal antibodies (MAbs) has greatly expanded the application and use of immunoassays. Polyclonal reagents, with their associated problems of specificity and quality control, have now been largely replaced by readily available MAbs of potential immortality and well-defined specificity and affinity. This has resulted, in the last two decades, in a great expansion in the range of immunoassays available and also a significant improvement in their reproducibility and reliability.

  8. Highly sensitive immunoassay based on E. coli with autodisplayed Z-domain

    International Nuclear Information System (INIS)

    Jose, Joachim; Park, Min; Pyun, Jae-Chul

    2010-01-01

    The Z-domain of protein A has been known to bind specifically to the F c region of antibodies (IgGs). In this work, the Z-domain of protein A was expressed on the outer membrane of Escherichia coli by using 'Autodisplay' technology as a fusion protein of autotransport domain. The E. coli with autodisplayed Z-domain was applied to the sandwich-type immunoassay as a solid-support of detection-antibodies against a target analyte. For the feasibility demonstration of the E. coli based immunoassay, C-reactive protein (CRP) assay was carried out by using E. coli with autodisplayed Z-domain. The limit of detection (LOD) and binding capacity of the E. coli based immunoassay were estimated to be far more sensitive than the conventional ELISA. Such a far higher sensitivity of E. coli based immunoassay than conventional ELISA was explained by the orientation control of immobilized antibodies and the mobility of E. coli in assay matrix. From the test results of 45 rheumatoid arthritis (RA) patients' serum and 15 healthy samples, a cut-off value was established to have optimal sensitivity and selectivity values for RA. The CRP test result of each individual sample was compared with ELISA which is the reference method for RA diagnosis. From this work, the E. coli with Z-domain was proved to be feasible for the medical diagnosis based on sandwich-type immunoassay.

  9. Advanced techniques in immunoassay

    International Nuclear Information System (INIS)

    Toth, G.

    1982-01-01

    A brief overview of the development history of radioimmunoassay and related techniques with their theory and practice are given. A comparison of radioimmunoassay (RIA), enzyme immunoassay (EIA), spin immunoassay (SIA), sequential saturation analysis (SSA) etc., based on their main parameters, and their fields of application and recent trends are presented. (Sz.J.)

  10. Radiolabelling for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Since the early 1960s labelled compounds employed in immunoassay techniques, both radioimmunoassay and immunoradiometric assay, have involved radioisotopes typically 3 H (tritium) and 125 Iodine. With the advent of increasingly stringent governmental regulations regarding usage and disposal of radioisotopes and the impetus of research towards improved immunoassay sensitivity following the discovery of monoclonal antibodies and their application to excess reagent immunometric assay methodology, radioisotopic labels are gradually being replaced by non-isotopic labels: enzyme, fluorescence and chemiluminescence

  11. Survey of immunoassay techniques for biological analysis

    International Nuclear Information System (INIS)

    Burtis, C.A.

    1986-10-01

    Immunoassay is a very specific, sensitive, and widely applicable analytical technique. Recent advances in genetic engineering have led to the development of monoclonal antibodies which further improves the specificity of immunoassays. Originally, radioisotopes were used to label the antigens and antibodies used in immunoassays. However, in the last decade, numerous types of immunoassays have been developed which utilize enzymes and fluorescent dyes as labels. Given the technical, safety, health, and disposal problems associated with using radioisotopes, immunoassays that utilize the enzyme and fluorescent labels are rapidly replacing those using radioisotope labels. These newer techniques are as sensitive, are easily automated, have stable reagents, and do not have a disposal problem. 6 refs., 1 fig., 2 tabs

  12. FY1995 development of a novel rapid immunoassay technology; 1995 nendo shinkina kosoku men'eki sokutei gijutsu no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    By utilizing the phenomenon that the antigen induces association of VH and VL, which are the antigen-recognizing fragments of antibody, develop a novel rapid immunoassay technology which will eliminate the defects of conventional immunoassays, such as long measuring time and requirement of expensive large automated apparatus. In addition, develop a methodology to make Fvs with low VH-VL affinity but that associate tightly in the presence of antigen. Using a model anti-hen egg lysozyme antibody HyHEL-10 Fv and BlAcore, we have clarified the kinetic basis of the Fv stabilization by HEL. By labeling HyHEL-10 VH, VL with succinimide esters of fluorescein and tetramethylrhodamin, respectively, at their N-termini, we could successfully detect VH-VL association by the increment of fluorescence resonance energy transfer. As a result, 1 {mu} g/ml of antigen could be detected homogeneously in less than 5 minutes. Some VH-VL association measurement systems were made by utilizing M13 phage display of VH fragments of HyHEL-10, anti-nitrophenacetyl, anti-digoxin antibodies. (NEDO)

  13. Multiplex detection of plant pathogens using a microsphere immunoassay technology.

    Directory of Open Access Journals (Sweden)

    Ratthaphol Charlermroj

    Full Text Available Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac, chilli vein-banding mottle virus (CVbMV, potyvirus, watermelon silver mottle virus (WSMoV, tospovirus serogroup IV and melon yellow spot virus (MYSV, tospovirus. An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour was much shorter than that of ELISA (4 hours. This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection.

  14. Multiplex detection of plant pathogens using a microsphere immunoassay technology.

    Science.gov (United States)

    Charlermroj, Ratthaphol; Himananto, Orawan; Seepiban, Channarong; Kumpoosiri, Mallika; Warin, Nuchnard; Oplatowska, Michalina; Gajanandana, Oraprapai; Grant, Irene R; Karoonuthaisiri, Nitsara; Elliott, Christopher T

    2013-01-01

    Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac), chilli vein-banding mottle virus (CVbMV, potyvirus), watermelon silver mottle virus (WSMoV, tospovirus serogroup IV) and melon yellow spot virus (MYSV, tospovirus). An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE)-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA) when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour) was much shorter than that of ELISA (4 hours). This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection.

  15. Label-Free Electrochemical Immunoassay for C-Reactive Protein

    Directory of Open Access Journals (Sweden)

    Madasamy Thangamuthu

    2018-03-01

    Full Text Available C-reactive protein (CRP is one of the most expressed proteins in blood during acute phase inflammation, and its minute level increase has also been recognized for the clinical diagnosis of cardio vascular diseases. Unfortunately, the available commercial immunoassays are labour intensive, require large sample volumes, and have practical limitations, such as low stability and high production costs. Hence, we have developed a simple, cost effective, and label-free electrochemical immunoassay for the measurement of CRP in a drop of serum sample using an immunosensor strip made up of a screen printed carbon electrode (SPE modified with anti-CRP functionalized gold nanoparticles (AuNPs. The measurement relies on the decrease of the oxidation current of the redox indicator Fe3+/Fe2+, resulting from the immunoreaction between CRP and anti-CRP. Under optimal conditions, the present immunoassay measures CRP in a linear range from 0.4–200 nM (0.047–23.6 µg mL−1, with a detection limit of 0.15 nM (17 ng mL−1, S/N = 3 and sensitivity of 90.7 nA nM−1, in addition to a good reproducibility and storage stability. The analytical applicability of the presented immunoassay is verified by CRP measurements in human blood serum samples. This work provides the basis for a low-priced, safe, and easy-to-use point-of-care immunosensor assay to measure CRP at clinically relevant concentrations.

  16. Massively multi-parametric immunoassays using ICPMS

    International Nuclear Information System (INIS)

    Tanner, S.D.; Ornatsky, O.; Bandura, D.R.; Baranov, V.I.

    2009-01-01

    The use of stable isotopes as tags in immunoassays, and their determination by ICPMS, is poised to have a huge impact on multi-parametric bioanalysis. A new technology, which we term 'mass cytometry', enables high throughput, highly multiplexed individual cell analysis. Preliminary results for T-cell immunophenotyping in peripheral blood mononuclear cells (PBMC), agonist influence on concomitant phosphorylation pathways, and sub-classification of acute myeloid leukemia patients' samples will be presented. The significance of individual cell analysis is demonstrated by the identification of populations of rogue cells in PBMC samples through the use of multidimensional neural network cluster analysis. (author)

  17. Abbott prism: a multichannel heterogeneous chemiluminescence immunoassay analyzer.

    Science.gov (United States)

    Khalil, O S; Zurek, T F; Tryba, J; Hanna, C F; Hollar, R; Pepe, C; Genger, K; Brentz, C; Murphy, B; Abunimeh, N

    1991-09-01

    We describe a multichannel heterogeneous immunoassay analyzer in which a sample is split between disposable reaction trays in a group of linear tracks. The system's pipettor uses noninvasive sensing of the sample volume and disposable pipet tips. Each assay track has (a) a conveyor belt for moving reaction trays to predetermined functional stations, (b) temperature-controlled tunnels, (c) noncontact transfer of the reaction mixture between incubation and detection wells, and (d) single-photon counting to detect a chemiluminescence (CL) signal from the captured immunochemical product. A novel disposable reaction tray, with separate reaction and detection wells and self-contained fluid removal, is used in conjunction with the transfer device on the track to produce a carryover-free system. The linear immunoassay track has nine predetermined positions for performing individual assay steps. Assay step sequence and timing is selected by changing the location of the assay modules between these predetermined positions. The assay methodology, a combination of microparticle capture and direct detection of a CL signal on a porous matrix, offers excellent sensitivity, specificity, and ease of automation. Immunoassay configurations have been tested for hepatitis B surface antigen and for antibodies to hepatitis B core antigen, hepatitis C virus, human immunodeficiency virus I and II, and human T-cell leukemia virus I and II.

  18. Microfluidic Platform for Enzyme-Linked and Magnetic Particle-Based Immunoassay

    Directory of Open Access Journals (Sweden)

    Dorota G. Pijanowska

    2013-06-01

    Full Text Available This article presents design and testing of a microfluidic platform for immunoassay. The method is based on sandwiched ELISA, whereby the primary antibody is immobilized on nitrocelluose and, subsequently, magnetic beads are used as a label to detect the analyte. The chip takes approximately 2 h and 15 min to complete the assay. A Hall Effect sensor using 0.35-μm BioMEMS TSMC technology (Taiwan Semiconductor Manufacturing Company Bio-Micro-Electro-Mechanical Systems was fabricated to sense the magnetic field from the beads. Furthermore, florescence detection and absorbance measurements from the chip demonstrate successful immunoassay on the chip. In addition, investigation also covers the Hall Effect simulations, mechanical modeling of the bead–protein complex, testing of the microfluidic platform with magnetic beads averaging 10 nm, and measurements with an inductor-based system.

  19. IFSA: a microfluidic chip-platform for frit-based immunoassay protocols

    Science.gov (United States)

    Hlawatsch, Nadine; Bangert, Michael; Miethe, Peter; Becker, Holger; Gärtner, Claudia

    2013-03-01

    Point-of-care diagnostics (POC) is one of the key application fields for lab-on-a-chip devices. While in recent years much of the work has concentrated on integrating complex molecular diagnostic assays onto a microfluidic device, there is a need to also put comparatively simple immunoassay-type protocols on a microfluidic platform. In this paper, we present the development of a microfluidic cartridge using an immunofiltration approach. In this method, the sandwich immunoassay takes place in a porous frit on which the antibodies have immobilized. The device is designed to be able to handle three samples in parallel and up to four analytical targets per sample. In order to meet the critical cost targets for the diagnostic market, the microfluidic chip has been designed and manufactured using high-volume manufacturing technologies in mind. Validation experiments show comparable sensitivities in comparison with conventional immunofiltration kits.

  20. Catch and measure-mass spectrometry-based immunoassays in biomarker research.

    Science.gov (United States)

    Weiß, Frederik; van den Berg, Bart H J; Planatscher, Hannes; Pynn, Christopher J; Joos, Thomas O; Poetz, Oliver

    2014-05-01

    Mass spectrometry-based (MS) methods are effective tools for discovering protein biomarker candidates that can differentiate between physiological and pathophysiological states. Promising candidates are validated in studies comprising large patient cohorts. Here, targeted protein analytics are used to increase sample throughput. Methods involving antibodies, such as sandwich immunoassays or Western blots, are commonly applied at this stage. Highly-specific and sensitive mass spectrometry-based immunoassays that have been established in recent years offer a suitable alternative to sandwich immunoassays for quantifying proteins. Mass Spectrometric ImmunoAssays (MSIA) and Stable Isotope Standards and Capture by Anti-Peptide Antibodies (SISCAPA/iMALDI) are two prominent types of MS-based immunoassays in which the capture is done either at the protein or the peptide level. We present an overview of these emerging types of immunoassays and discuss their suitability for the discovery and validation of protein biomarkers. This article is part of a Special Issue entitled: Biomarkers: A Proteomic Challenge. © 2013.

  1. Microfluidic "Pouch" Chips for Immunoassays and Nucleic Acid Amplification Tests.

    Science.gov (United States)

    Mauk, Michael G; Liu, Changchun; Qiu, Xianbo; Chen, Dafeng; Song, Jinzhao; Bau, Haim H

    2017-01-01

    Microfluidic cassettes ("chips") for processing and analysis of clinical specimens and other sample types facilitate point-of-care (POC) immunoassays and nucleic acid based amplification tests. These single-use test chips can be self-contained and made amenable to autonomous operation-reducing or eliminating supporting instrumentation-by incorporating laminated, pliable "pouch" and membrane structures for fluid storage, pumping, mixing, and flow control. Materials and methods for integrating flexible pouch compartments and diaphragm valves into hard plastic (e.g., acrylic and polycarbonate) microfluidic "chips" for reagent storage, fluid actuation, and flow control are described. We review several versions of these pouch chips for immunoassay and nucleic acid amplification tests, and describe related fabrication techniques. These protocols thus offer a "toolbox" of methods for storage, pumping, and flow control functions in microfluidic devices.

  2. Detection of alpha-fetoprotein in magnetic immunoassay of thin channels using biofunctional nanoparticles

    Science.gov (United States)

    Tsai, H. Y.; Gao, B. Z.; Yang, S. F.; Li, C. S.; Fuh, C. Bor

    2014-01-01

    This paper presents the use of fluorescent biofunctional nanoparticles (10-30 nm) to detect alpha-fetoprotein (AFP) in a thin-channel magnetic immunoassay. We used an AFP model biomarker and s-shaped deposition zones to test the proposed detection method. The results show that the detection using fluorescent biofunctional nanoparticle has a higher throughput than that of functional microparticle used in previous experiments on affinity reactions. The proposed method takes about 3 min (versus 150 min of previous method) to detect 100 samples. The proposed method is useful for screening biomarkers in clinical applications, and can reduce the run time for sandwich immunoassays to less than 20 min. The detection limits (0.06 pg/ml) and linear ranges (0.068 pg/ml-0.68 ng/ml) of AFP using fluorescent biofunctional nanoparticles are the same as those of using functional microparticles within experimental errors. This detection limit is substantially lower and the linear range is considerably wider than those of enzyme-linked immunosorbent assay (ELISA) and other methods in sandwich immunoassay methods. The differences between this method and an ELISA in AFP measurements of serum samples were less than 12 %. The proposed method provides simple, fast, and sensitive detection with a high throughput for biomarkers.

  3. Bead-based immunoassays

    NARCIS (Netherlands)

    Wal, van der F.J.; Bergervoet, J.H.W.; Achterberg, R.P.; Haasnoot, W.

    2014-01-01

    Since the first immunoassay with (radioactive) labeled antibodies in the middle of the 20th century [1], many different formats on various platforms have been developed, using antibodies for capture and/or detection. If antibodies are used to capture compounds, a support, such as the wall of a

  4. Surface-Enhanced Raman Scattering (SERS) for Detection in Immunoassays: applications, fundamentals, and optimization

    International Nuclear Information System (INIS)

    Jeremy Daniel Driskell

    2006-01-01

    Immunoassays have been utilized for the detection of biological analytes for several decades. Many formats and detection strategies have been explored, each having unique advantages and disadvantages. More recently, surface-enhanced Raman scattering (SERS) has been introduced as a readout method for immunoassays, and has shown great potential to meet many key analytical figures of merit. This technology is in its infancy and this dissertation explores the diversity of this method as well as the mechanism responsible for surface enhancement. Approaches to reduce assay times are also investigated. Implementing the knowledge gained from these studies will lead to a more sensitive immunoassay requiring less time than its predecessors. This dissertation is organized into six sections. The first section includes a literature review of the previous work that led to this dissertation. A general overview of the different approaches to immunoassays is given, outlining the strengths and weaknesses of each. Included is a detailed review of binding kinetics, which is central for decreasing assay times. Next, the theoretical underpinnings of SERS is reviewed at its current level of understanding. Past work has argued that surface plasmon resonance (SPR) of the enhancing substrate influences the SERS signal; therefore, the SPR of the extrinsic Raman labels (ERLs) utilized in our SERS-based immunoassay is discussed. Four original research chapters follow the Introduction, each presented as separate manuscripts. Chapter 2 modifies a SERS-based immunoassay previously developed in our group, extending it to the low-level detection of viral pathogens and demonstrating its versatility in terms of analyte type, Chapter 3 investigates the influence of ERL size, material composition, and separation distance between the ERLs and capture substrate on the SERS signal. This chapter links SPR with SERS enhancement factors and is consistent with many of the results from theoretical treatments

  5. Surface-Enhanced Raman Scattering (SERS) for Detection in Immunoassays. Applications, fundamentals, and optimization

    Energy Technology Data Exchange (ETDEWEB)

    Driskell, Jeremy Daniel [Iowa State Univ., Ames, IA (United States)

    2006-08-09

    Immunoassays have been utilized for the detection of biological analytes for several decades. Many formats and detection strategies have been explored, each having unique advantages and disadvantages. More recently, surface-enhanced Raman scattering (SERS) has been introduced as a readout method for immunoassays, and has shown great potential to meet many key analytical figures of merit. This technology is in its infancy and this dissertation explores the diversity of this method as well as the mechanism responsible for surface enhancement. Approaches to reduce assay times are also investigated. Implementing the knowledge gained from these studies will lead to a more sensitive immunoassay requiring less time than its predecessors. This dissertation is organized into six sections. The first section includes a literature review of the previous work that led to this dissertation. A general overview of the different approaches to immunoassays is given, outlining the strengths and weaknesses of each. Included is a detailed review of binding kinetics, which is central for decreasing assay times. Next, the theoretical underpinnings of SERS is reviewed at its current level of understanding. Past work has argued that surface plasmon resonance (SPR) of the enhancing substrate influences the SERS signal; therefore, the SPR of the extrinsic Raman labels (ERLs) utilized in our SERS-based immunoassay is discussed. Four original research chapters follow the Introduction, each presented as separate manuscripts. Chapter 2 modifies a SERS-based immunoassay previously developed in our group, extending it to the low-level detection of viral pathogens and demonstrating its versatility in terms of analyte type, Chapter 3 investigates the influence of ERL size, material composition, and separation distance between the ERLs and capture substrate on the SERS signal. This chapter links SPR with SERS enhancement factors and is consistent with many of the results from theoretical treatments

  6. Fake news? Biotin interference in thyroid immunoassays.

    Science.gov (United States)

    Koehler, Viktoria F; Mann, Ulrike; Nassour, Ayham; Alexander Mann, W

    2018-05-29

    We report on a 47 year old male patient with multiple sclerosis (MS) presenting in our outpatient neurology clinic in Frankfurt/Main for therapy evaluation. Before change of treatment laboratory investigations were performed. Thyroid function tests (TFTs) with a streptavidin/biotin based immunoassay revealed severe hyperthyroidism with positive thyroid autoantibodies suggestive for Graves' disease. Clinical presentation and thyroid sonography were unremarkable. Due to the discordance between clinical presentation and TFTs, we repeated medical history, in which the patient reported taking high-doses of biotin (300 mg/day) for MS. Recent studies with patients suffering from primary and secondary progressive MS, indicated promising effects of high-dose biotin on MS-related disability. In immunoassays relaying on streptavidin-biotin interaction, biotin intake can cause falsely high or low results. Two weeks after withdrawing biotin, biotin/streptavidin dependant assays showed no longer the biochemical picture of severe hyperthyroidism. Biotin intake should be paused for at least two to five days prior to the use of biotin/streptavidin dependant assays. Alternatively, non-biotin/streptavidin dependant assays (radioimmunoassay, gas chromatography-mass spectrometry/liquid chromatography-mass spectrometry) may be used. Copyright © 2017. Published by Elsevier B.V.

  7. Comparison of capillary electrophoresis-based immunoassay with fluorescence polarization immunoassay for the immunodetermination of methamphetamine using various methamphetamine antibodies.

    Science.gov (United States)

    Choi, J; Kim, C; Choi, M J

    1998-11-01

    An accurate and simple immunoassay using capillary electrophoresis (CE) with laser-induced fluorescence (LIF) was performed for the detection of methamphetamine (MA) in urine. The CE-LIF was conducted with an untreated fused-silica column using antiserum and a tracer of fluorescein isothiocyanate (FITC)-labeled MA. This CE-LIF system was compared with fluorescence polarization immunoassay (FPIA) in a TDx analyzer in the photo-check mode using the same FITC-labeled tracer and the same antiserum. Various antibodies, not only those prepared by our own immunogens but also those from commercial sources, were screened and characterized in both assay systems with regard to sensitivity, precision, and cross-reactivity. Both systems satisfied analytical precision and gave similar cross-reactivity patterns. However, the CE-LIF-based immunoassay was approximately one order superior to FPIA in sensitivity, requiring less volume of sample, antiserum, and tracer for the assay. Considering that the FPIA system is well known to be a useful tool for screening antibodies and detecting drugs, the CE-LIF-based immunoassay system, which is seemingly more advantageous than the FPIA system, appears to have great power for the characterization of antibodies and for the detection of MA in urine.

  8. Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay

    OpenAIRE

    Ruzzenente, Orazio; Salvagno, Gian Luca; Gelati, Matteo; Lippi, Giuseppe

    2016-01-01

    Objectives: This study was designed to evaluate the analytical performance of the novel Lumipulse G1200 BRAHMS procalcitonin (PCT) immunoassay. Design and methods: This analytical evaluation encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the Vidas BRAHMS PCT assay. Results: The LOB, LOD and functional sensitivity were 0.0010 ng/mL, 0.0016 ng/mL and ...

  9. Recent advancements in the immunoassay domain

    International Nuclear Information System (INIS)

    Pradelles, Ph.

    1997-01-01

    The two types of immunoassay techniques, the competition analysis and the immuno-metric analysis (sandwich type), are described; the tracers used with theses methods have high specific radioactivity levels in order to be traced at extremely low content. Non radioactive tracers have been also developed, such as enzymatic, fluorescent, luminescent tracers, which are simpler and may be used at home. The Cea has recently developed some innovative immunoassay formats, such as acetylcholinesterase as a new enzymatic tracer, and immuno-metric dosage for very small molecules such as haptenes

  10. Ultrasensitive colorimetric immunoassay for hCG detection based on dual catalysis of Au@Pt core-shell nanoparticle functionalized by horseradish peroxidase

    Science.gov (United States)

    Wang, Weiguo; Zou, Yake; Yan, Jinwu; Liu, Jing; Chen, Huixiong; Li, Shan; Zhang, Lei

    2018-03-01

    In this paper, an ultrasensitive colorimetric biosensor for human chorionic gonadotrophin (hCG) detection was designed from bottom-up method based on the dual catalysis of the horseradish peroxidase (HRP) and Au@Pt nanoparticles (NPs) relative to H2O2-TEM system. HRP and monoclonal mouse anti-hCG antibody (β-submit, mAb1) were co-immobilized onto the Au@Pt NP surface to improve catalytic efficiency and specificity, which formed a dual functionalized Au@Pt-HRP probe with the mean size of 42.8 nm (D50). The colorimetric immunoassay was developed for the hCG detection, and the Au@Pt-HRP probe featured a higher sensitivity in the concentration range of 0.4-12.8 IU L- 1 with a low limit of detection (LOD) of 0.1 IU L- 1 compared with the LODs of 0.8 IU L- 1 for BA-ELISA and of 2.0 IU L- 1 for Au@Pt, which indicated that the Au@Pt-HRP probe possessed higher catalytic efficiency with 2.8-fold increase over Au@Pt and 33.8-fold increase over HRP. Also, the Au@Pt-HRP probe exhibited good precision and reproducibility, high specificity and acceptable accuracy with CV being less than 15%. The dual functionalized Au@Pt-HRP probe as a type of signal amplified method was firstly applied in the colorimetric immunoassay for the hCG detection.

  11. Review of the biochemical basis of enzyme immunoassays

    International Nuclear Information System (INIS)

    Klingler, W.

    1982-01-01

    The ever increasing number of radioimmunological determination poses problems allied with the handling of radioactive substances. In recent years various non-radioactive methods have been developed, among which the enzyme immunoassay is already in routine use. Homogeneous and heterogeneous enzyme immunoassays are described. Criteria for enzymes, substrates and enzyme-substrate reactions are listed. (orig.) [de

  12. Detection of Avian Influenza Virus by Fluorescent DNA Barcode-based Immunoassay with Sensitivity Comparable to PCR

    DEFF Research Database (Denmark)

    Cao, Cuong; Dhumpa, Raghuram; Bang, Dang Duong

    2010-01-01

    involves the sandwiching of the target AIV between magnetic immunoprobes and barcode-carrying immunoprobes. Because each barcode-carrying immunoprobe is functionalized with a multitude of fluorophore-DNA barcode strands, many DNA barcodes are released for each positive binding event resulting......In this paper, a coupling of fluorophore-DNA barcode and bead-based immunoassay for detecting avian influenza virus (AIV) with PCR-like sensitivity is reported. The assay is based on the use of sandwich immunoassay and fluorophore-tagged oligonucleotides as representative barcodes. The detection...

  13. Oriented antibody immobilization to polystyrene macrocarriers for immunoassay modified with hydrazide derivatives of poly(methacrylic acid

    Directory of Open Access Journals (Sweden)

    Vinokurova Ludmila G

    2001-08-01

    Full Text Available Abstract Background Hydrophobic polystyrene is the most common material for solid phase immunoassay. Proteins are immobilized on polystyrene by passive adsorption, which often causes considerable denaturation. Biological macromolecules were found to better retain their functional activity when immobilized on hydrophilic materials. Polyacrylamide is a common material for solid-phase carriers of biological macromolecules, including immunoreagents used in affinity chromatography. New macroformats for immunoassay modified with activated polyacrylamide derivatives seem to be promising. Results New polymeric matrices for immunoassay in the form of 0.63-cm balls which contain hydrazide functional groups on hydrophilic polymer spacer arms at their surface shell are synthesized by modification of aldehyde-containing polystyrene balls with hydrazide derivatives of poly(methacrylic acid. The beads contain up to 0.31 μmol/cm2 active hydrazide groups accessible for covalent reaction with periodate-oxidized antibodies. The matrices obtained allow carrying out the oriented antibody immobilization, which increases the functional activity of immunosorbents. Conclusions An efficient site-directed antibody immobilization on a macrosupport is realized. The polymer hydrophilic spacer arms are the most convenient and effective tools for oriented antibody coupling with molded materials. The suggested scheme can be used for the modification of any other solid supports containing electrophilic groups reacting with hydrazides.

  14. Three-dimensional nanoflower-like MnO2 functionalized graphene as catalytically promoted nanolabels for ultrasensitive electrochemiluminescence immunoassay

    International Nuclear Information System (INIS)

    Su, Min; Zhang, Yan; Song, Xianrang; Ge, Shenguang; Yan, Mei; Yu, Jinghua; Huang, Jiadong

    2013-01-01

    A novel electrochemiluminescence (ECL) immunosensor based on the peroxydisulfate solution for detection of prostate-specific antigen (PSA) has been developed. In this work, gold nanoparticles (AuNPs) were electrodeposited on the glassy carbon electrode surface, which could increase the surface area to capture a large amount of primary antibodies as well as to improve the electronic transmission rate. The as-prepared bionanolabels, three-dimensional (3D) nanoflower-like MnO 2 functionalized graphene (GN/MnO 2 ), with novel hybrid architecture were initially fabricated via electrostatic interaction. Then, to provide an effective matrix for antibody immobilization with good stability and bioactivity, the novel materials were modified by AuNPs with the aid of poly (diallyldimethylammonium chloride) via a simple sonication-induced assembly method. In this immunosensor, MnO 2 with the characteristics of well electrochemical behavior, low cost, and environmental-friendly, is used as a substitute for horseradish peroxidase to catalyze H 2 O 2 to produce O 2 , and its 3D nanoflower-like structure is beneficial for the unparallel surface-to-volume ratio. Furthermore, a simple, low-cost and portable home-made potential transformer was utilized in this system to take the place of conventional electrochemical workstation. With a sandwich-type immunoassay format, the amount of functionalized GN/MnO 2 labeled antibodies increased with the increment of antigens in the samples, which implied that the ECL signals enhanced with the increase of in situ generated O 2 due to the enhancive catalysis of MnO 2 to the H 2 O 2 . The immunosensor displayed excellent analytical performance for the detection of PSA in the range of 0.005–10 ng mL −1 with a detection limit of 2.5 pg mL −1 at 3σ. Moreover, the proposed method showed good precision, acceptable stability and reproducibility, and could be used for the detection of PSA in real samples. The proposed method provides a new

  15. Integrated immunoassay using tuneable surface acoustic waves and lensfree detection.

    Science.gov (United States)

    Bourquin, Yannyk; Reboud, Julien; Wilson, Rab; Zhang, Yi; Cooper, Jonathan M

    2011-08-21

    The diagnosis of infectious diseases in the Developing World is technologically challenging requiring complex biological assays with a high analytical performance, at minimal cost. By using an opto-acoustic immunoassay technology, integrating components commonly used in mobile phone technologies, including surface acoustic wave (SAW) transducers to provide pressure driven flow and a CMOS camera to enable lensfree detection technique, we demonstrate the potential to produce such an assay. To achieve this, antibody functionalised microparticles were manipulated on a low-cost disposable cartridge using the surface acoustic waves and were then detected optically. Our results show that the biomarker, interferon-γ, used for the diagnosis of diseases such as latent tuberculosis, can be detected at pM concentrations, within a few minutes (giving high sensitivity at a minimal cost). This journal is © The Royal Society of Chemistry 2011

  16. Chemiluminescence immunoassay for chloramphenicol

    International Nuclear Information System (INIS)

    Lin Si; Xu Wenge; Liu Yibing

    2007-06-01

    A simple, solid-phase chemiluminescence immunoassay (CLIA) for the measurement of Chloramphenicol(CAP) in foodstuffs is described. A rabbit anti-CAP IgG is passively adsorbed onto the walls of polypropylene plates. The labeled conjugant is horseradish peroxidase(HRP) conjugate of CAP. Luminol solution is used as the substrate of HRP. The light yield is inversely proportional to the concentration of CAP. The method has a similar sensitivity (0.05 ng/mL), specificity, precision, and accuracy to a conventional enzyme immunoassay (EIA). The intra-assay and inter-assay CVs of ten samples were <8 and <20%, respectively, and the analytical recovery of the method was 87% 100%. The experimental correlation coefficient of dilution was found to be 0.999 using milk supernatant as buffer. The assay range for the method was 0.1-10 ng/mL, and it displayed good linearity. (authors)

  17. In vitro conditions modify immunoassayability of bovine pituitary prolactin and growth hormone: insights into their secretory granule storage forms

    International Nuclear Information System (INIS)

    Lorenson, M.Y.

    1985-01-01

    The amount of immunoassayable intracellular bovine (b) PRL and GH varies depending on treatment conditions. The present studies were designed to characterize the mechanisms involved and to compare immunoassayability of both hormones under similar conditions. Pituitary homogenate and secretory granule hormones displayed both time- and temperature-dependent increases when incubated at pH 10.5 with reduced glutathione. Changes in immunoassayability seem to reflect conversion from poorly immunoactive tissue hormone oligomers to monomeric hormone. The data indicate that oligomeric bPRL is stabilized primarily by intermolecular disulfide bonds, although it is also susceptible to urea, SDS, and EDTA; granule thiols may also influence the conversion to monomer. The storage form of bGH appears to be stabilized differently. Maneuvers demonstrated in these studies to influence immunoassayability correlate very well with their previously established effects on hormone release and secretion, strengthening the likelihood that a functional link exists between assayability and secretion

  18. Linkage of biomolecules to solid phases for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Topics covered by this lecture include a brief review of the principal methods of linkage of biomolecules to solid phase matrices. Copies of the key self explanatory slides are presented as figures together with reprints of two publications by the author dealing with a preferred chemistry for the covalent linkage of antibodies to hydroxyl and amino functional groups and the effects of changes in solid phase matrix and antibody coupling chemistry on the performance of a typical excess reagent immunoassay for thyroid stimulating hormone

  19. The immunoassay handbook

    National Research Council Canada - National Science Library

    Wild, David (David G.)

    2001-01-01

    ... importantly, enabling them to keep current on the basic theory behind immunoassay. Since the publication of the previous edition in 1994, the field has continued to evolve rapidly, and the need for a fully updated version of this book is now paramount. The second edition has been comprehensively updated and new chapters have been added to each section" [publisher's web site].

  20. Evaluation of Six Different Immunoassays for Serum Thyrotropin

    International Nuclear Information System (INIS)

    Ma Donghong; Lu Hankui; Gao Yunchao; Ge Wenli; Xiong Jiang; Liu Qiaoping; Gu Qing

    2010-01-01

    To analyzes the discrepancy and association among six different thyrotropin (TSH) immunoassay methods and to study their impact on the clinical diagnoses of thyroid diseases, the 150 serum samples from three groups consisting of hyperthyroidism, hypothyroidism and healthy subjects, 50 samples in each group were included in this study. The serum TSH levels were measured simultaneously by radioimmunoassay (RIA), immunoradiometric assay (IRMA), three-type chemilumiminescence immunoassay (CLIA) and electrochemiluminescence immunoassay (ECLIA). The results showed that individual serum TSH level varied significantly from one assay to another. There was no correlation between TSH RIA and other five assays in groups of hyperthyroidism and healthy subjects(P>0.05). The correlations between TSH IRMA and four automatic assays in hyperthyroidism group were relatively low (r= 0.38∼0.41). However, among the four automatic assays, TSH levels were well correlated (r= 0.92∼0.99). For clinical diagnoses, TSH RIA alone was not useful in the differentiation of hyperthyroidism and normal subjects, and TSH IRMA was misleading in some hyperthyroidism. There were no significant differences for four TSH automatic immunoassays in differential diagnoses of thyroid diseases. (authors)

  1. Nanobody medicated immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein.

    Science.gov (United States)

    Chen, Jing; He, Qing-hua; Xu, Yang; Fu, Jin-heng; Li, Yan-ping; Tu, Zhui; Wang, Dan; Shu, Mei; Qiu, Yu-lou; Yang, Hong-wei; Liu, Yuan-yuan

    2016-01-15

    Immunoassay for cancer biomarkers plays an important role in cancer prevention and early diagnosis. To the development of immunoassay, the quality and stability of applied antibody is one of the key points to obtain reliability and high sensitivity for immunoassay. The main purpose of this study was to develop a novel immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein (AFP) based on nanobody against AFP. Two nanobodies which bind to AFP were selected from a phage display nanobody library by biopanning strategy. The prepared nanobodies are clonable, thermally stable and applied in both sandwich enzyme linked immunoassay (ELISA) and immuno-PCR assay for ultrasensitive detection of AFP. The limit detection of sandwich ELISA setup with optimized nanobodies was 0.48ng mL(-1), and the half of saturation concentration (SC50) value was 6.68±0.56ng mL(-1). These nanobodies were also used to develop an immuno-PCR assay for ultrasensitive detection of AFP, its limit detection values was 0.005ng mL(-1), and the linear range was 0.01-10,000ng mL(-1). These established immunoassays based on nanobodies were highly specific to AFP and with negligible cross reactivity with other tested caner biomarkers. Furthermore, this novel concept of nanobodies mediated immunoassay may provide potential applications in a general method for the ultrasensitive detection of various cancer biomarkers. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Design of novel hybrid organic-inorganic nanostructured biomaterials for immunoassay applications

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, G [Department of Microbiology, Institute of Biological Sciences, Federal University of Minas Gerais, PO Box 486, 31270.901, Belo Horizonte, MG (Brazil); Barbosa-Stancioli, E F [Department of Microbiology, Institute of Biological Sciences, Federal University of Minas Gerais, PO Box 486, 31270.901, Belo Horizonte, MG (Brazil); Piscitelli Mansur, A A [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil); Vasconcelos, W L [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil); Mansur, H S [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil)

    2006-12-01

    The purpose of this study was to develop novel hybrid organic-inorganic materials based on poly(vinyl alcohol) (PVA) polymer chemically crosslinked network to be tested as solid support on bovine herpesvirus immunoassay. Hybrids were synthesized by reacting PVA with three different alkoxysilanes modifying chemical groups: tetraethoxysilane (TEOS), 3-mercaptopropyltrimethoxysilane (MPTMS) and 3-glycidoxypropyltrimethoxysilane (GPTMS). PVA-derived hybrids were also modified by chemically crosslinking with glutaraldehyde (GA) during the synthesis reaction. In order to investigate the structure in the nanometer-scale, PVA-derived hybrids were characterized by using small-angle x-ray scattering synchrotron radiation (SAXS) and x-ray diffraction (XRD). PVA hybrids' chemical functionalities and their interaction with herpesviruses were also characterized by Fourier transform infrared spectroscopy (FTIR). The bioactivity assays were tested through enzyme linked immunosorbent assay (ELISA). SAXS results have indicated nano-ordered disperse domains for PVA hybrids with different x-ray scattering patterns for PVA polymer and PVA-derived hybrids. FTIR spectra have shown major vibration bands associated with organic-inorganic chemical groups present in the PVA, PVA-derived by silane modifier and PVA chemically crosslinked by GA. The immunoassay results have shown that PVA hybrids with chemically functionalized structures regulated to some extent the specific bioimmobilization of herpesvirus onto solid phase. We think that it is due to the overall balance of forces associated with van der Waals interaction, hydrophilic and hydrophobic forces and steric hindrance acting at the surface. PVA and PVA-derived hybrid materials were successfully produced with GA crosslinking in a nanometer-scale network. Also, such a PVA-based material could be advantageously used in immunoassays with enhanced specificity for diagnosis.

  3. Design of novel hybrid organic-inorganic nanostructured biomaterials for immunoassay applications

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, G [Department of Microbiology, Institute of Biological Sciences, Federal University of Minas Gerais, PO Box 486, 31270.901, Belo Horizonte, MG (Brazil); Barbosa-Stancioli, E F [Department of Microbiology, Institute of Biological Sciences, Federal University of Minas Gerais, PO Box 486, 31270.901, Belo Horizonte, MG (Brazil); Piscitelli Mansur, A A [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil); Vasconcelos, W L [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil); Mansur, H S [Department of Metallurgical and Materials Engineering, Biomaterials and Tissue Engineering Laboratory, Federal University of Minas Gerais, Belo Horizonte, MG (Brazil)

    2006-12-01

    The purpose of this study was to develop novel hybrid organic-inorganic materials based on poly(vinyl alcohol) (PVA) polymer chemically crosslinked network to be tested as solid support on bovine herpesvirus immunoassay. Hybrids were synthesized by reacting PVA with three different alkoxysilanes modifying chemical groups: tetraethoxysilane (TEOS), 3-mercaptopropyltrimethoxysilane (MPTMS) and 3-glycidoxypropyltrimethoxysilane (GPTMS). PVA-derived hybrids were also modified by chemically crosslinking with glutaraldehyde (GA) during the synthesis reaction. In order to investigate the structure in the nanometer-scale, PVA-derived hybrids were characterized by using small-angle x-ray scattering synchrotron radiation (SAXS) and x-ray diffraction (XRD). PVA hybrids' chemical functionalities and their interaction with herpesviruses were also characterized by Fourier transform infrared spectroscopy (FTIR). The bioactivity assays were tested through enzyme linked immunosorbent assay (ELISA). SAXS results have indicated nano-ordered disperse domains for PVA hybrids with different x-ray scattering patterns for PVA polymer and PVA-derived hybrids. FTIR spectra have shown major vibration bands associated with organic-inorganic chemical groups present in the PVA, PVA-derived by silane modifier and PVA chemically crosslinked by GA. The immunoassay results have shown that PVA hybrids with chemically functionalized structures regulated to some extent the specific bioimmobilization of herpesvirus onto solid phase. We think that it is due to the overall balance of forces associated with van der Waals interaction, hydrophilic and hydrophobic forces and steric hindrance acting at the surface. PVA and PVA-derived hybrid materials were successfully produced with GA crosslinking in a nanometer-scale network. Also, such a PVA-based material could be advantageously used in immunoassays with enhanced specificity for diagnosis.

  4. Effective gasoline site assessment using the D TECH trademark BTEX immunoassay

    International Nuclear Information System (INIS)

    Hudak, R.T.; Melby, J.M.; Stave, J.W.

    1994-01-01

    The application of immunoassay to environmental testing can greatly aid in assessing sites for various contaminants including PCB, TNT, RDX, PAH and BTEX. Immunoassay offers several benefits to site assessment: it is accurate, reproducible and relatively inexpensive compared to instrumental analysis. In addition, because of its ease-of-use, this technique is ideal for the field and requires minimal user training. To demonstrate not only the effectiveness of the BTEX immunoassay, but also the reliability of the field results, a gasoline contaminated site was assessed comparing the BTEX immunoassay to gas chromatography. All sampling and site related activities were executed in accordance to the USEPA SW-846 guidelines. Three (3) analyses were performed on each sample. One immunoassay analysis was performed in the field by an individual who received two (2) hours of training prior to the start of the study. A technician familiar with the immunoassay ran the second analysis in a laboratory. Finally, an independent GC laboratory certified for BTEX method 8020 and 602 performed the GC analyses. One hundred one (101) samples were analyzed: thirty-nine (39) samples were water, the other sixty-two (62) were soils ranging from clay to silt. The results and costs of the methods are compared

  5. Upconverting nanophosphors as reporters in a highly sensitive heterogeneous immunoassay for cardiac troponin I

    Energy Technology Data Exchange (ETDEWEB)

    Sirkka, Nina, E-mail: nkelon@utu.fi; Lyytikäinen, Annika; Savukoski, Tanja; Soukka, Tero

    2016-06-21

    Photon upconverting nanophosphors (UCNPs) have a unique capability to produce anti-Stokes emission at visible wavelengths via sequential multiphoton absorption upon infrared excitation. Since the anti-Stokes emission can be easily spectrally resolved from the Stokes' shifted autofluorescence, the upconversion luminescence (UCL) is a highly attractive reporter technology for optical biosensors and biomolecular binding assays – potentially enabling unprecedented sensitivity in separation-based solid-phase immunoassays. UCL technology has not previously been applied in sensitive detection of cardiac troponin I (cTnI), which requires highly sensitive detection to enable accurate and timely diagnosis of myocardial infarction. We have developed an UCL-based immunoassay for cTnI using NaYF{sub 4}: Yb{sup 3+}, Er{sup 3+} UCNPs as reporters. Biotinylated anti-cTnI monoclonal antibody (Mab) and Fab fragment immobilized to streptavidin-coated wells were used to capture cTnI. Captured cTnI was detected from dry well surface after a 15 min incubation with poly(acrylic acid) coated UCNPs conjugated to second anti-cTnI Mab. UCL was measured with a dedicated UCL microplate reader. The UCL-based immunoassay allowed sensitive detection of cTnI. The limit of detection was 3.14 ng L{sup −1}. The calibration curve was linear up to cTnI concentration 50,000 ng L{sup −1}. Plasma recoveries of added cTnI were 92–117%. Obtained cTnI concentrations from five normal plasma samples were 4.13–10.7 ng L{sup −1} (median 5.06 ng L{sup −1}). There is yet significant potential for even further improved limit of detection by reducing non-specifically bound fraction of the Mab-conjugated UCNPs. The assay background with zero calibrator was over 40-fold compared to the background obtained from wells where the reporter conjugate had been excluded. - Highlights: • Detection of attomole analyte quantity in microwell using upconversion luminescence. • Upconverting

  6. Nanoparticle-based sandwich electrochemical immunoassay for carbohydrate antigen 125 with signal enhancement using enzyme-coated nanometer-sized enzyme-doped silica beads.

    Science.gov (United States)

    Tang, Dianping; Su, Biling; Tang, Juan; Ren, Jingjing; Chen, Guonan

    2010-02-15

    A novel nanoparticle-based electrochemical immunoassay of carbohydrate antigen 125 (CA125) as a model was designed to couple with a microfluidic strategy using anti-CA125-functionalized magnetic beads as immunosensing probes. To construct the immunoassay, thionine-horseradish peroxidase conjugation (TH-HRP) was initially doped into nanosilica particles using the reverse micelle method, and then HRP-labeled anti-CA125 antibodies (HRP-anti-CA125) were bound onto the surface of the synthesized nanoparticles, which were used as recognition elements. Different from conventional nanoparticle-based electrochemical immunoassays, the recognition elements of the immunoassay simultaneously contained electron mediator and enzyme labels and simplified the electrochemical measurement process. The sandwich-type immunoassay format was used for the online formation of the immunocomplex in an incubation cell and captured in the detection cell with an external magnet. The electrochemical signals derived from the carried HRP toward the reduction of H(2)O(2) using the doped thionine as electron mediator. Under optimal conditions, the electrochemical immunoassay exhibited a wide working range from 0.1 to 450 U/mL with a detection limit of 0.1 U/mL CA125. The precision, reproducibility, and stability of the immunoassay were acceptable. The assay was evaluated for clinical serum samples, receiving in excellent accordance with results obtained from the standard enzyme-linked immunosorbent assay (ELISA) method. Concluding, the nanoparticle-based assay format provides a promising approach in clinical application and thus represents a versatile detection method.

  7. Fluorescence immunoassay for detecting periodontal bacterial pathogens in plaque.

    OpenAIRE

    Wolff, L F; Anderson, L; Sandberg, G P; Aeppli, D M; Shelburne, C E

    1991-01-01

    A particle concentration fluorescence immunoassay has been modified into a bacterial concentration fluorescence immunoassay (BCFIA) to rapidly detect periodontopathic bacteria in human plaque samples. The BCFIA utilizes fluorescently tagged monoclonal antibodies (MAbs) directed against the lipopolysaccharide of selected gram-negative plaque bacteria. Microorganisms closely associated with periodontal disease that can be identified in plaque with the BCFIA include Porphyromonas gingivalis, Bac...

  8. NiCoBP-doped carbon nanotube hybrid: A novel oxidase mimetic system for highly efficient electrochemical immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bing; He, Yu; Liu, Bingqian; Tang, Dianping, E-mail: dianping.tang@fzu.edu.cn

    2014-12-03

    Highlights: • We report a new oxidase mimetic system for highly efficient electrochemical immunoassay. • NiCoBP-doped carbon nanotube hybrids were used as the nanocatalysts. • NiCoBP-doped carbon nanotube hybrids were used as the mimic oxidase. - Abstract: NiCoBP-doped multi-walled carbon nanotube (NiCoBP–MWCNT) was first synthesized by using induced electroless-plating method and functionalized with the biomolecules for highly efficient electrochemical immunoassay of prostate-specific antigen (PSA, used as a model analyte). We discovered that the as-synthesized NiCoBP–MWCNT had the ability to catalyze the glucose oxidization with a stable and well-defined redox peak. The catalytic current increased with the increment of the immobilized NiCoBP–MWCNT on the electrode. Transmission electron microscope (TEM) and energy dispersive X-ray spectrometry (EDX) were employed to characterize the as-prepared NiCoBP–MWCNT. Using the NiCoBP–MWCNT-conjugated anti-PSA antibody as the signal-transduction tag, a new enzyme-free electrochemical immunoassay protocol could be designed for the detection of target PSA on the capture antibody-functionalized immunosensing interface. Experimental results revealed that the designed immunoassay system could exhibit good electrochemical responses toward target PSA, and allowed the detection of PSA at a concentration as low as 0.035 ng mL{sup −1}. More importantly, the NiCoBP-MWCNT-based oxidase mimetic system could be further extended for the monitoring of other low-abundance proteins or disease-related biomarkers by tuning the target antibody.

  9. Chemiluminescence enzyme immunoassay based on magnetic nanoparticles for detection of hepatocellular carcinoma marker glypican-3

    Directory of Open Access Journals (Sweden)

    Qian-Yun Zhang

    2011-08-01

    Full Text Available Glypican-3 (GPC3 is reported as a great promising tumor marker for hepatocellular carcinoma (HCC diagnosis. Highly sensitive and accurate analysis of serum GPC3 (sGPC3, in combination with or instead of traditional HCC marker alpha-fetoprotein (AFP, is essential for early diagnosis of HCC. Biomaterial-functionalized magnetic particles have been utilized as solid supports with good biological compatibility for sensitive immunoassay. Here, the magnetic nanoparticles (MnPs and magnetic microparticles (MmPs with carboxyl groups were further modified with streptavidin, and applied for the development of chemiluminescence enzyme immunoassay (CLEIA. After comparing between MnPs- and MmPs-based CLEIA, MnPs-based CLEIA was proved to be a better method with less assay time, greater sensitivity, better linearity and longer chemiluminescence platform. MnPs-based CLEIA was applied for detection of sGPC3 in normal liver, hepatocirrhosis, secondary liver cancer and HCC serum samples. The results indicated that sGPC3 was effective in diagnosis of HCC with high performance. Keywords: Magnetic nanoparticle, Magnetic microparticle, Chemiluminescence enzyme immunoassay, Glypican-3, Hepatocellular carcinoma

  10. Detection of narcotics with an immunoassay film badge

    International Nuclear Information System (INIS)

    Lukens, H.R.

    1993-01-01

    Efficient personnel performance, a major requirement for a safe nuclear industry, is jeopardized where personnel use narcotics. However, detection of narcotics at nuclear plants is a challenge. The unique specificity and sensitivity of an immunoassay has been implemented in the form of a small, dry immunoassay film badge (IFB) for the detection of vapors emitted by narcotics. The device is suitable as an area monitor, and its characteristics are suitable for use as a breath monitor for the detection of drug use

  11. Development of national immunoassay reagent programmes

    International Nuclear Information System (INIS)

    Sufi, S.B.; Micallef, J.V.; Ahsan, R.; Goncharov, N.P.

    1992-01-01

    Despite the existence of networks of fully equipped laboratories with well-trained staff, the availability of immunodiagnostic services in developing countries is often limited by the high cost of imported kits. There are a number of ways of tackling this problem, ranging from bulk purchase of kits or reagents to local development and production of assay systems. Argentina/Chile, China, Cuba/Mexico, and Thailand are amongst the countries which have established local immunoassay reagent programmes to manufacture low cost, high quality immunoassay reagents. Kits from these projects are now beginning to become available, and it is hoped that they will promote national diagnostic services and research, as well as stimulating the development of reagent programmes for other analytes. (author). 4 refs, 1 tab

  12. Control of (pre-analytical aspects in immunoassay measurements of metabolic hormones in rodents

    Directory of Open Access Journals (Sweden)

    Maximilian Bielohuby

    2018-04-01

    Full Text Available The measurement of circulating hormones by immunoassay remains a cornerstone in preclinical endocrine research. For scientists conducting and interpreting immunoassay measurements of rodent samples, the paramount aim usually is to obtain reliable and meaningful measurement data in order to draw conclusions on biological processes. However, the biological variability between samples is not the only variable affecting the readout of an immunoassay measurement and a considerable amount of unwanted or unintended variability can be quickly introduced during the pre-analytical and analytical phase. This review aims to increase the awareness for the factors ‘pre-analytical’ and ‘analytical’ variability particularly in the context of immunoassay measurement of circulating metabolic hormones in rodent samples. In addition, guidance is provided how to gain control over these variables and how to avoid common pitfalls associated with sample collection, processing, storage and measurement. Furthermore, recommendations are given on how to perform a basic validation of novel single and multiplex immunoassays for the measurement of metabolic hormones in rodents. Finally, practical examples from immunoassay measurements of plasma insulin in mice address the factors ‘sampling site and inhalation anesthesia’ as frequent sources of introducing an unwanted variability during the pre-analytical phase. The knowledge about the influence of both types of variability on the immunoassay measurement of circulating hormones as well as strategies to control these variables are crucial, on the one hand, for planning and realization of metabolic rodent studies and, on the other hand, for the generation and interpretation of meaningful immunoassay data from rodent samples.

  13. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    DEFF Research Database (Denmark)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter

    2017-01-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum......, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on europium chelate as a fluorescent marker. The system performance was tested with the immunoassay based...... on the cardiac marker, TnI. The same signal-to-noise ratio as for the flash lamp based system was obtained, operating the LED below specified maximum current. The background counts of the system and its main contributors were measured and analyzed. The background of the system of the LED based unit was improved...

  14. Determining total thyroxine with the aid of the homogeneous enzyme immunoassay

    International Nuclear Information System (INIS)

    Vogt, W.

    1978-01-01

    Total thyrozine values obtained with the aid of the homogeneous enzyme immunoassay are compared with those delivered by the RIA and the efficiency of the EMIT technique is evaluated. Some results obtained via Enzymun-T4, a heterologous enzyme immunoassay, are also given. (VJ) 891 VJ [de

  15. A Switchable Linker-Based Immunoassay for Ultrasensitive Visible Detection of Salmonella in Tomatoes.

    Science.gov (United States)

    Hahn, Jungwoo; Kim, Eunghee; You, Young Sang; Gunasekaran, Sundaram; Lim, Seokwon; Choi, Young Jin

    2017-10-01

    On-site detection for sensitive identification of foodborne pathogens on fresh produce with minimal use of specialized instrumentation is crucial to the food industry. A switchable linker (SL)-based immunoassay was designed for ultrasensitive on-site detection of Salmonella in tomato samples. The assay is based on large-scale aggregation of gold nanoparticles (GNPs), induced by a quantitative relationship among the biotinylated Salmonella polyclonal antibody (b-Ab) used as the SL, the functionalized GNPs, and Salmonella. Important factors such as the concentration of SLs, time required for large-scale aggregation, and selectivity of b-Ab were optimized to minimize the detection time (within 45 min with gentle agitation) and achieve the lowest limit of detection (LOD; 10 CFU/g in tomato samples) possible. This SL-based immunoassay with its relatively low LOD and short detection time may meet the need for rapid, simple, on-site analysis of pathogens in fresh produce. The novel switchable linker-based immunoassay is a rapid, specific, and sensitive method that has potential applications for routine diagnostics of Salmonella in tomato products. These advantages make it a practical approach for general use in the processing industry to detect Salmonella rapidly and to implement appropriate regulatory procedures. Furthermore, it could be applied to other fresh products including cantaloupe, strawberry, and cucumbers. © 2017 Institute of Food Technologists®.

  16. Multiplex Immunoassay Profiling of Hormones Involved in Metabolic Regulation.

    Science.gov (United States)

    Stephen, Laurie; Guest, Paul C

    2018-01-01

    Multiplex immunoassays are used for rapid profiling of biomarker proteins and small molecules in biological fluids. The advantages over single immunoassays include lower sample consumption, cost, and labor. This chapter details a protocol to develop a 5-plex assay for glucagon-like peptide 1, growth hormone, insulin, leptin, and thyroid-stimulating hormone on the Luminex ® platform. The results of the analysis of insulin in normal control subjects are given due to the important role of this hormone in nutritional programming diseases.

  17. Potential applications of immunoassays in studies of flatfish recruitment

    Science.gov (United States)

    Feller, Robert J.

    The fisheries recruitment-stock problem, a lack of correlation between measures of reproductive output of the parent stock and recruitment to the fishery, has several potential biotic and abiotic causes. Immunoassays may be useful in examining several aspects of this and several other problems in flatfish ecology: stock identification, parasitism and disease, and trophic interactions. Given stage-specific antisera capable of recognozing antigenic moieties of, for instance, eggs, larvae, or newly-settled juveniles, it is possible to screen stomach contents of many putative predators ( e.g., shrimp or crabs) rapidly for the presence and amounts of platfish prey. This trophic application of immunological methods has great promise for measuring loss of potential recruits to predation. All immunoassays are limited by the quality of antisera used and the researcher's ability to interpret quantitative data in an ecologically meaningful way. Key references for applications of immunoassays in fish-related questions are provided with recommendations for their utilization.

  18. Negative interference by rheumatoid factor in alpha-fetoprotein chemiluminescent microparticle immunoassay.

    Science.gov (United States)

    Wang, Hui; Bi, Xiaohui; Xu, Lei; Li, Yirong

    2017-01-01

    Background Rheumatoid factor causes positive interference in multiple immunoassays. Recently, negative interference has also been found in immunoassays in the presence of rheumatoid factor. The chemiluminescent microparticle immunoassay is widely used to determine serum alpha-fetoprotein. However, it is not clear whether the presence of rheumatoid factor in the serum causes interference in the chemiluminescent microparticle immunoassay of alpha-fetoprotein. Methods Serum alpha-fetoprotein was determined using the ARCHITECT alpha-fetoprotein assay. The estimation of alpha-fetoprotein recovery was carried out in samples prepared by diluting high-concentration alpha-fetoprotein serum with rheumatoid factor-positive or rheumatoid factor-negative serum. Paramagnetic microparticles coated with hepatitis B surface antigen-anti-HBs complexes were used to remove rheumatoid factor from the serum. Results The average recovery of alpha-fetoprotein was 88.4% and 93.8% in the rheumatoid factor-positive and rheumatoid factor-negative serum samples, respectively. The recovery of alpha-fetoprotein was significantly lower in the rheumatoid factor-positive serum samples than in the rheumatoid factor-negative serum samples. In two of five rheumatoid factor-positive samples, a large difference was found (9.8%) between the average alpha-fetoprotein recoveries in the serially diluted and initial recoveries. Fourteen rheumatoid factor-positive serum samples were pretreated with hepatitis B surface antigen-anti-HBs complex-coated paramagnetic microparticles. The alpha-fetoprotein concentrations measured in the pretreated samples increased significantly. Conclusions It was concluded that the alpha-fetoprotein chemiluminescent microparticle immunoassay is susceptible to interference by rheumatoid factor, leading to significantly lower results. Eliminating the incidence of negative interference from rheumatoid factor should be an important goal for immunoassay providers. In the meantime

  19. Development of a novel ultrasensitive enzyme immunoassay for human glutamic acid decarboxylase 65 antibody.

    Science.gov (United States)

    Numata, Satoshi; Katakami, Hideki; Inoue, Shinobu; Sawada, Hirotake; Hashida, Seiichi

    2016-07-01

    We developed a novel, ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for determination of glutamic acid decarboxylase autoantibody concentrations in serum samples from patients with type 2 diabetes. We developed an immune complex transfer enzyme immunoassay for glutamic acid decarboxylase autoantibody and measured glutamic acid decarboxylase autoantibody from 22 patients with type 1 diabetes, 29 patients with type 2 diabetes, and 32 healthy controls. A conventional ELISA kit identified 10 patients with type 1 diabetes and one patient with type 2 diabetes as glutamic acid decarboxylase autoantibody positive, whereas 15 patients with type 1 diabetes and six patients with type 2 diabetes were identified as glutamic acid decarboxylase autoantibody positive using immune complex transfer enzyme immunoassay. Immune complex transfer enzyme immunoassay is a highly sensitive and specific assay for glutamic acid decarboxylase autoantibody and might be clinically useful for diabetic onset prediction and early diagnosis. © The Author(s) 2016.

  20. Molecularly Imprinted Polymer as an Antibody Substitution in Pseudo-immunoassays for Chemical Contaminants in Food and Environmental Samples.

    Science.gov (United States)

    Chen, Chaochao; Luo, Jiaxun; Li, Chenglong; Ma, Mingfang; Yu, Wenbo; Shen, Jianzhong; Wang, Zhanhui

    2018-03-21

    The chemical contaminants in food and the environment are quite harmful to food safety and human health. Rapid, accurate, and cheap detection can effectively control the potential risks derived from these chemical contaminants. Among all detection methods, the immunoassay based on the specific interaction of antibody-analyte is one of the most widely used techniques in the field. However, biological antibodies employed in the immunoassay usually cannot tolerate extreme conditions, resulting in an unstable state in both physical and chemical profiles. Molecularly imprinted polymers (MIPs) are a class of polymers with specific molecular recognition abilities, which are highly robust, showing excellent operational stability under a wide variety of conditions. Recently, MIPs have been used in biomimetic immunoassays for chemical contaminants as an antibody substitute in food and the environment. Here, we reviewed these applications of MIPs incorporated in different analytical platforms, such as enzyme-linked immunosorbent assay, fluorescent immunoassay, chemiluminescent immunoassay, electrochemical immunoassay, microfluidic paper-based immunoassay, and homogeneous immunoassay, and discussed current challenges and future trends in the use of MIPs in biomimetic immunoassays.

  1. Heparin interferes with the radioenzymatic and homogeneous enzyme immunoassays for aminoglycosides

    International Nuclear Information System (INIS)

    Krogstad, D.J.; Granich, G.G.; Murray, P.R.; Pfaller, M.A.; Valdes, R.

    1981-01-01

    Heparin interferes with measurement of aminoglycosides in serum by biological, radioenzymatic, and homogeneous enzyme immunoassay techniques, but not with radioimmunoassay. At concentrations greater than or equal to 10 5 and greater than or equal to 3 X 10 6 USP units/L, respectively, it interferes with the radioenzymatic assay by inhibiting the gentamicin 3-acetyltransferase and kanamycin 6'-acetyltransferase enzymes used in the assay. It interferes with the homogeneous enzyme immunoassays for gentamicin and tobramycin (at concentrations greater than or equal to 10 5 and greater than or equal to10 4 USP units/L, respectively), but not with the commercially available homogeneous enzyme immunoassays for other drugs. Heparin interference with the homogeneous enzyme immunoassay for aminoglycosides requires both the heparin polyanion and glucose-6-phosphate dehydrogenase bound to a cationic aminoglycoside. This interference can be reproduced with dextran sulfate (but not dextran), and does not occur with free enzyme (glucose-6-phosphate dehydrogenase) alone. Heparin interference with these two assays and at concentrations that may be present in intravenous infusions or in seriously underfilled blood-collection tubes is described

  2. Functionalized gold nanorod-based labels for amplified electrochemical immunoassay of E. coli as indicator bacteria relevant to the quality of dairy product.

    Science.gov (United States)

    Zhang, Xinai; Zhang, Fan; Zhang, Hongyin; Shen, Jianzhong; Han, En; Dong, Xiaoya

    2015-01-01

    In this paper, we report an amplified electrochemical immunoassay for Escherichia coli as indicator bacteria relevant to the quality of dairy product using the functionalized gold nanorod-based labels ({dAb-AuNR-FCA}). The {dAb-AuNR-FCA} labels were designed by exploiting silica-functionalized gold nanorods (AuNR@SiO2) as the carriers for immobilization of detection antibody (dAb) and ferrocenecarboxylic acid (FCA), in which dAb was used for recognition of E. coli and FCA tags served as signal-generating molecule. Greatly amplified signal was achieved in the sandwich-type immunoassay when enormous FCA linked to AuNR@SiO2. Compared with the commercially available {dAb-FCA}, the {dAb-AuNR-FCA} labels exhibited a better performance for E. coli assay due to the advantages of AuNR@SiO2 as carriers. Under optimal experimental conditions, it showed a linear relationship between the peak current of FCA and the logarithmic value of E. coli concentration ranging from 1.0×10(2) to 5.0×10(4) cfu mL(-1) with a detection limit of 60 cfu mL(-1) (S/N=3), and the electrochemical detection of E. coli could be achieved in 3h. Moreover, the proposed strategy was used to determine E. coli in dairy product (pure fresh milk, yogurt in shelf-life, and expired yogurt), and the recoveries of standard additions were in the range of 95.1-106%. This proposed strategy exhibited rapid response, high sensitivity and specificity for E. coli assay in dairy product, and could become a promising technique to estimate the quality of dairy product. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Sensitivity-Enhancement of FRET Immunoassays by Multiple-Antibody Conjugation on Quantum Dots.

    Science.gov (United States)

    Annio, Giacomo; Jennings, Travis; Tagit, Oya; Hildebrandt, Niko

    2018-05-23

    Quantum dots (QDs) are not only advantageous for color-tuning, improved brightness, and high stability, but their nanoparticle surfaces also allow for the attachment of many biomolecules. Because IgG antibodies (ABs) are in the same size range of biocompatible QDs and the AB orientation after conjugation to the QD is often random, it is difficult to predict if few or many ABs per QD will lead to an efficient AB-QD conjugate. This is particularly true for homogeneous Förster resonance energy transfer (FRET) sandwich immunoassays, for which the ABs on the QD must bind a biomarker that needs to bind a second AB-FRET-conjugate. Here, we investigate the performance of Tb-to-QD FRET immunoassays against total prostate specific antigen (TPSA) by changing the number of ABs per QD while leaving all the other assay components unchanged. We first characterize the AB-QD conjugation by various spectroscopic, microscopic, and chromatographic techniques and then quantify the TPSA immunoassay performance regarding sensitivity, limit of detection, and dynamic range. Our results show that an increasing conjugation ratio leads to significantly enhanced FRET immunoassays. These findings will be highly important for developing QD-based immunoassays in which the concentrations of both ABs and QDs can significantly influence the assay performance.

  4. Development of nanobody-based flow injection chemiluminescence immunoassay for sensitive detection of human prealbumin.

    Science.gov (United States)

    Ma, Lei; Sun, Yanyan; Kang, Xuejun; Wan, Yakun

    2014-11-15

    Nanobodies, derived from camelid heavy-chain antibodies, have novel and impactful applications in clinical diagnostics. Our objective is to develop a nanobody-based chemiluminescence immunoassay for sensitive detection of human prealbumin (PA). In this context, a phage display nanobody library is constructed via immunizing dromedary camel with human prealbumin. Three nanobodies have been identified by five successive bio-panning steps. Based on their high expression level and good affinity, two out of three are chosen for further study. Magnetic beads (MBs) were functionalized with PEI by acylamide bond formed between the carboxyl group on the surface of the MB. Then, an anti-PA nanobody (Nb1) can be effectively immobilized onto the surface of the functionalized MB using glutaradehyde as the link. The modified MBs with Nb1 can specifically capture the target PA and reacted with silica nanoparticles with co-immobilized HRP and anti-PA nanobody (Nb2). The concentration of PA was detected by flow injection chemiluminescence. When using MB/PEI as the carrier of anti-PA Nb1, the CL signal significantly increased to 4-fold compared with the signal using MB without PEI modification. The CL signal was further amplified to 5-fold when Si/Nb2 was used as the signal probe. Under optimized conditions, the present immunoassay exhibited a wide quantitative range from 0.05 to 1000 μg L(-1) with a detection limit of 0.01 μg L(-1). The sensitivity of the proposed immunoassay offers great promises in providing a sensitive, specific, time saving, and potential method for detecting PA in clinical settings. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    OpenAIRE

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2017-01-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on ...

  6. Giant unilamellar vesicles containing Rhodamine 6G as a marker for immunoassay of bovine serum albumin and lipocalin-2.

    Science.gov (United States)

    Sakamoto, Misato; Shoji, Atsushi; Sugawara, Masao

    2016-07-15

    Functionalized giant unilamellar vesicles (GUVs) containing a fluorescence dye Rhodamine 6G is proposed as a marker in sandwich-type immunoassay for bovine serum albumin (BSA) and lipocalin-2 (LCN2). The GUVs were prepared by the electroformation method and functionalized with anti-BSA antibody and anti-LCN2 antibody, respectively. The purification of antibody-modified GUVs was achieved by conventional centrifugation and a washing step in a flow system. To antigen on an antibody slip, antibody-modified GUVs were added as a marker and incubated. After wash-out of excess reagents and lysis of the bound GUVs with Triton X-100, the fluorescence image was captured. The fluorometric immunoassays for BSA and LCN2 exhibited lower detection limits of 4 and 80 fg ml(-)(1), respectively. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Procedures for Sensitive Immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Givol, D. [Department of Chemical Immunology, Weizmann Institute of Science, Rehovot (Israel)

    1970-02-15

    Sensitive immunoassay methods should be applied to small molecules of biological importance, which are non-immunogenic by themselves, such as small peptide hormones (e.g. bradykinin), plant hormones (e.g. indoleacetic acid), nucleotides and other small molecules. Methods of binding these small molecules, as haptens, to immunogenic carriers by various cross-linking agents are described (dicyclohexylcarbodiimide, tolylene-diisocyanate and glutaraldehyde), and the considerations involved in relation to the methods of binding and the specificity of the antibodies formed are discussed. Some uses of antibody bound to bromoacetyl cellulose as an immuno adsorbent convenient for assay of immunoglobulins are described. Finally, the sensitive immunoassay method of chemically modified phage is described. This includes methods of binding small molecules (such as the dinitrophenyl group, penicillin, indoleacetic acid) or proteins (such as insulin, immunoglobulins) to phages. Methods of direct chemical conjugation, or an indirect binding via anti-phage Fab, are described. The phage inactivation method by direct plating and its modifications (such as decision technique and complex inactivation) are compared with the more simple end-point titration method. The inhibition of phage inactivation has some advantages as it does not require radioactive material, or expensive radioactive counters, and avoids the need for separation between bound and unbound antigen. Hence, if developed, it could be used as an alternative to radioimmunoassay. (author)

  8. Immunoassay for determination of trilobolide

    Czech Academy of Sciences Publication Activity Database

    Huml, L.; Jurášek, M.; Mikšátková, P.; Zimmermann, T.; Tomanová, P.; Buděšínský, Miloš; Rottnerová, Z.; Šimková, M.; Harmatha, Juraj; Kmoníčková, Eva; Lapčík, O.; Drašar, P. B.

    2017-01-01

    Roč. 117, Jan (2017), s. 105-111 ISSN 0039-128X. [Conference on Isoprenoids /23./. Minsk, 04.09.2016-07.09.2016] Institutional support: RVO:61388963 ; RVO:68378041 Keywords : trilobolide * avidin-biotin * ELISA * Laser trilobum * synthesis * immunoassay Subject RIV: CE - Biochemistry; FR - Pharmacology ; Medidal Chemistry (UEM-P) OBOR OECD: Biochemical research methods; Pharmacology and pharmacy (UEM-P) Impact factor: 2.282, year: 2016

  9. Development of immunoassays for detecting clothianidin residue in agricultural products.

    Science.gov (United States)

    Li, Ming; Sheng, Enze; Cong, Lujing; Wang, Minghua

    2013-04-17

    Two enzyme-linked immunosorbent assays (ELISAs) based on polyclonal antibodies (PcAbs) for clothianidin are described: colorimetric detection format (ELISA) and pattern of chemiluminescent assay (CLEIA). Clothianidin hapten was synthesized and conjugated to bovine serum albumin (BSA) and ovalbumin (OVA) to produce immunogen and coating antigen. Anticlothianidin PcAbs were obtained from immunized New Zealand white rabbits. Under optimal conditions, the half-maximal inhibition concentration (IC₅₀) and the limit of detection (LOD, IC₂₀) of clothianidin were 0.046 and 0.0028 mg/L for the ELISA and 0.015 and 0.0014 mg/L for the CLEIA, respectively. There were no obvious cross-reactivities of the antibodies with its analogues except for dinotefuran. Recoveries of 76.4-116.4% for the immunoassays were achieved from spiked samples. The results of immunoassays for the spiked and authentic samples were largely consistent with gas chromatography. Therefore, the proposed immunoassays would be convenient and satisfactory analytical methods for the monitoring of clothianidin in agricultural products.

  10. Good performance of an immunoassay based method for nevirapine measurements in human breast milk

    DEFF Research Database (Denmark)

    Salado-Rasmussen, Kirsten; Theilgaard, Zahra Persson; Chiduo, Mercy

    2011-01-01

    from HIV-uninfected women. Clinical samples from HIV-infected women receiving a single-dose of nevirapine were analyzed. Results: Precision and accuracy were evaluated with two concentrations of quality control materials analyzed in three replicates on four different days and was......, requires complicated extraction techniques. The ARK method employs an immunoassay technology and requires a small sample volume (40 μL) and no pre-treatment of the samples. Methods: Commercial enzyme and antibody were used and calibration standards and quality controls were prepared from pooled breast milk...

  11. Printing technologies for biomolecule and cell-based applications.

    Science.gov (United States)

    Ihalainen, Petri; Määttänen, Anni; Sandler, Niklas

    2015-10-30

    Biomolecules, such as enzymes, proteins and other biomacromolecules (polynucleotides, polypeptides, polysaccharides and DNA) that are immobilized on solid surfaces are relevant to many areas of science and technology. These functionalized surfaces have applications in biosensors, chromatography, diagnostic immunoassays, cell culturing, DNA microarrays and other analytical techniques. Printing technologies offer opportunities in this context. The main interests in printing biomolecules are in immobilizing them on surfaces for sensors and catalysts or for controlled delivery of protein-based drugs. Recently, there have been significant developments in the use of inkjet printing for dispensing of proteins, biomacromolecules and cells. This review discusses the use of roll-to-roll and inkjet printing technologies in manufacturing of biomolecule and cell-based applications. Copyright © 2015. Published by Elsevier B.V.

  12. History of inductively coupled plasma mass spectrometry-based immunoassays

    International Nuclear Information System (INIS)

    Giesen, Charlotte; Waentig, Larissa; Panne, Ulrich; Jakubowski, Norbert

    2012-01-01

    The analysis of biomolecules requires highly sensitive and selective detection methods capable of tolerating a complex, biological matrix. First applications of biomolecule detection by ICP-MS relied on the use of heteroelements as a label for quantification. However, the combination of immunoassays and ICP-MS facilitates multiparametric analyses through elemental tagging, and provides a powerful alternative to common bioanalytical methods. This approach extends the detection of biomarkers in clinical diagnosis, and has the potential to provide a deeper understanding of the investigated biological system. The results might lead to the detection of diseases at an early stage, or guide treatment plans. Immunoassays are well accepted and established for diagnostic purposes, albeit ICP-MS is scarcely applied for the detection of immune-based assays. However, the screening of biomarkers demands high throughput and multiplex/multiparametric techniques, considering the variety of analytes to be queried. Finally, quantitative information on the expression level of biomarkers is highly desirable to identify abnormalities in a given organism. Thus, it is the aim of this review to introduce the fundamentals, and to discuss the enormous strength of ICP-MS for the detection of different immunoassays on the basis of selected applications, with a special focus on LA‐ICP‐MS. - Highlights: ► We discuss the fundamentals of elemental tagging for ICP‐MS applications. ► We propose a definition for the expressions “label” and “tag”. ► We highlight LA‐ICP‐MS‐based heteroelement detection. ► We give an historic overview on ICP-MS and LA‐ICP‐MS-based immunoassays. ► In a personal outlook, we discuss future improvements realistically attainable.

  13. Lateral Flow Immunoassays for Ebola Virus Disease Detection in Liberia.

    Science.gov (United States)

    Phan, Jill C; Pettitt, James; George, Josiah S; Fakoli, Lawrence S; Taweh, Fahn M; Bateman, Stacey L; Bennett, Richard S; Norris, Sarah L; Spinnler, David A; Pimentel, Guillermo; Sahr, Phillip K; Bolay, Fatorma K; Schoepp, Randal J

    2016-10-15

    Lateral flow immunoassays (LFIs) are point-of-care diagnostic assays that are designed for single use outside a formal laboratory, with in-home pregnancy tests the best-known example of these tests. Although the LFI has some limitations over more-complex immunoassay procedures, such as reduced sensitivity and the potential for false-positive results when using complex sample matrices, the assay has the benefits of a rapid time to result and ease of use. These benefits make it an attractive option for obtaining rapid results in an austere environment. In an outbreak of any magnitude, a field-based rapid diagnostic assay would allow proper patient transport and for safe burials to be conducted without the delay caused by transport of samples between remote villages and testing facilities. Use of such point-of-care instruments in the ongoing Ebola virus disease (EVD) outbreak in West Africa would have distinct advantages in control and prevention of local outbreaks, but proper understanding of the technology and interpretation of results are important. In this study, a LFI, originally developed by the Naval Medical Research Center for Ebola virus environmental testing, was evaluated for its ability to detect the virus in clinical samples in Liberia. Clinical blood and plasma samples and post mortem oral swabs submitted to the Liberian Institute for Biomedical Research, the National Public Health Reference Laboratory for EVD testing, were tested and compared to results of real-time reverse transcription-polymerase chain reaction (rRT-PCR), using assays targeting Ebola virus glycoprotein and nucleoprotein. The LFI findings correlated well with those of the real-time RT-PCR assays used as benchmarks. Rapid antigen-detection tests such as LFIs are attractive alternatives to traditional immunoassays but have reduced sensitivity and specificity, resulting in increases in false-positive and false-negative results. An understanding of the strengths, weaknesses, and

  14. Automation on an Open-Access Platform of Alzheimer's Disease Biomarker Immunoassays.

    Science.gov (United States)

    Gille, Benjamin; Dedeene, Lieselot; Stoops, Erik; Demeyer, Leentje; Francois, Cindy; Lefever, Stefanie; De Schaepdryver, Maxim; Brix, Britta; Vandenberghe, Rik; Tournoy, Jos; Vanderstichele, Hugo; Poesen, Koen

    2018-04-01

    The lack of (inter-)laboratory standardization has hampered the application of universal cutoff values for Alzheimer's disease (AD) cerebrospinal fluid (CSF) biomarkers and their transfer to general clinical practice. The automation of the AD biomarker immunoassays is suggested to generate more robust results than using manual testing. Open-access platforms will facilitate the integration of automation for novel biomarkers, allowing the introduction of the protein profiling concept. A feasibility study was performed on an automated open-access platform of the commercial immunoassays for the 42-amino-acid isoform of amyloid-β (Aβ 1-42 ), Aβ 1-40 , and total tau in CSF. Automated Aβ 1-42 , Aβ 1-40 , and tau immunoassays were performed within predefined acceptance criteria for bias and imprecision. Similar accuracy was obtained for ready-to-use calibrators as for reconstituted lyophilized kit calibrators. When compared with the addition of a standard curve in each test run, the use of a master calibrator curve, determined before and applied to each batch analysis as the standard curve, yielded an acceptable overall bias of -2.6% and -0.9% for Aβ 1-42 and Aβ 1-40 , respectively, with an imprecision profile of 6.2% and 8.4%, respectively. Our findings show that transfer of commercial manual immunoassays to fully automated open-access platforms is feasible, as it performs according to universal acceptance criteria.

  15. Solid-Phase Immunoassay of Polystyrene-Encapsulated Semiconductor Coreshells for Cardiac Marker Detection

    Directory of Open Access Journals (Sweden)

    Sanghee Kim

    2012-01-01

    Full Text Available A solid-phase immunoassay of polystyrene-encapsulated semiconductor nanoparticles was demonstrated for cardiac troponin I (cTnI detection. CdSe/ZnS coreshells were encapsulated with a carboxyl-functionalized polystyrene nanoparticle to capture the target antibody through a covalent bonding and to eliminate the photoblinking and toxicity of semiconductor luminescent immunosensor. The polystyrene-encapsulated CdSe/ZnS fluorophores on surface-modified glass chip identified cTnI antigens at the level of ~ng/mL. It was an initial demonstration of diagnostic chip for monitoring a cardiovascular disease.

  16. Design and Fabrication of a PDMS Microchip Based Immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Guocheng; Wang, Wanjun; Wang, Jun; Lin, Yuehe

    2010-07-01

    In this paper, we describe the design and fabrication process of a polydimethylsiloxane (PDMS) microchip for on-chip multiplex immunoassay application. The microchip consists of a PDMS microfluidic channel layer and a micro pneumatic valve control layer. By selectively pressurizing the pneumatic microvalves, immuno reagents were controlled to flow and react in certain fluidic channel sites. Cross contamination was prevented by tightly closed valves. Our design was proposed to utilize PDMS micro channel surface as the solid phase immunoassay substrate and simultaneously detect four targets antigens on chip. Experiment result shows that 20psi valve pressure is sufficient to tightly close a 200µm wide micro channel with flow rate up to 20µl/min.

  17. Automated water analyser computer supported system (AWACSS) Part I: Project objectives, basic technology, immunoassay development, software design and networking.

    Science.gov (United States)

    Tschmelak, Jens; Proll, Guenther; Riedt, Johannes; Kaiser, Joachim; Kraemmer, Peter; Bárzaga, Luis; Wilkinson, James S; Hua, Ping; Hole, J Patrick; Nudd, Richard; Jackson, Michael; Abuknesha, Ram; Barceló, Damià; Rodriguez-Mozaz, Sara; de Alda, Maria J López; Sacher, Frank; Stien, Jan; Slobodník, Jaroslav; Oswald, Peter; Kozmenko, Helena; Korenková, Eva; Tóthová, Lívia; Krascsenits, Zoltan; Gauglitz, Guenter

    2005-02-15

    A novel analytical system AWACSS (automated water analyser computer-supported system) based on immunochemical technology has been developed that can measure several organic pollutants at low nanogram per litre level in a single few-minutes analysis without any prior sample pre-concentration nor pre-treatment steps. Having in mind actual needs of water-sector managers related to the implementation of the Drinking Water Directive (DWD) (98/83/EC, 1998) and Water Framework Directive WFD (2000/60/EC, 2000), drinking, ground, surface, and waste waters were major media used for the evaluation of the system performance. The instrument was equipped with remote control and surveillance facilities. The system's software allows for the internet-based networking between the measurement and control stations, global management, trend analysis, and early-warning applications. The experience of water laboratories has been utilised at the design of the instrument's hardware and software in order to make the system rugged and user-friendly. Several market surveys were conducted during the project to assess the applicability of the final system. A web-based AWACSS database was created for automated evaluation and storage of the obtained data in a format compatible with major databases of environmental organic pollutants in Europe. This first part article gives the reader an overview of the aims and scope of the AWACSS project as well as details about basic technology, immunoassays, software, and networking developed and utilised within the research project. The second part article reports on the system performance, first real sample measurements, and an international collaborative trial (inter-laboratory tests) to compare the biosensor with conventional anayltical methods.

  18. Preparation by irradiation of a solid support for enzyme immunoassay

    International Nuclear Information System (INIS)

    Kumakura, M.; Kaetsu, I.

    1984-01-01

    Reagents (immobilized anti-α-fetoprotein discs) having a porous structure were prepared for enzyme immunoassay of α-fetoprotein by radiation polymerization at low temperatures. Discs were attached to sticks for easy handling. The activity (determined by absorbance at 492 nm) of the discs varied with the hydrophilic properties and size of the discs. The discs are sufficiently sensitive and precise for enzyme immunoassay of α-fetoprotein. Anti-AFP dissolved in PBS solution was mixed with a monomer solution of hydroxyethyl methacrylate and hydroxypropyl methacrylate. The mixture was frozen to -78 0 C and gamma irradiated. (Auth.)

  19. 340nm UV LED excitation in time-resolved fluorescence system for europium-based immunoassays detection

    Science.gov (United States)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2017-02-01

    In immunoassay analyzers for in-vitro diagnostics, Xenon flash lamps have been widely used as excitation light sources. Recent advancements in UV LED technology and its advantages over the flash lamps such as smaller footprint, better wall-plug efficiency, narrow emission spectrum, and no significant afterglow, have made them attractive light sources for gated detection systems. In this paper, we report on the implementation of a 340 nm UV LED based time-resolved fluorescence system based on europium chelate as a fluorescent marker. The system performance was tested with the immunoassay based on the cardiac marker, TnI. The same signal-to-noise ratio as for the flash lamp based system was obtained, operating the LED below specified maximum current. The background counts of the system and its main contributors were measured and analyzed. The background of the system of the LED based unit was improved by 39% compared to that of the Xenon flash lamp based unit, due to the LEDs narrower emission spectrum and longer pulse width. Key parameters of the LED system are discussed to further optimize the signal-to-noise ratio and signal-to-background, and hence the sensitivity of the instrument.

  20. Microsphere-based immunoassay integrated with a microfluidic network to perform logic operations

    International Nuclear Information System (INIS)

    Sabhachandani, Pooja; Cohen, Noa; Sarkar, Saheli; Konry, Tania

    2015-01-01

    Lab on a chip (LOC) intelligent diagnostics can be described by molecular logic-based circuits. We report on the development of an LOC approach with logic capability for screening combinations of antigen and antibody in the same sample. A microsphere-based immunoassay was integrated with a microfluidic network device to perform the logic operations AND and INHIBIT. Using the clinically relevant biomarkers TNF-α cytokine and anti-TNF-α antibody, we obtained a fluorescent output in the presence of both inputs. This results in an AND operation, while the presence of only one specific input results in a different fluorescent signal, thereby indicating the INHIBIT operation. This approach demonstrates the effective use of molecular logic computation for developing portable, point-of-care technologies for diagnostic purposes due to fast detection times, minimal reagent consumption and low costs. This model system may be further expanded to screening of multiple disease markers, combinatorial logic applications, and developing “smart” sensors and therapeutic technologies. (author)

  1. Factitious Graves' Disease Due to Biotin Immunoassay Interference-A Case and Review of the Literature.

    Science.gov (United States)

    Elston, Marianne S; Sehgal, Shekhar; Du Toit, Stephen; Yarndley, Tania; Conaglen, John V

    2016-09-01

    Biotin (vitamin B7) is an essential co-factor for four carboxylases involved in fatty acid metabolism, leucine degradation, and gluconeogenesis. The recommended daily intake (RDI) of biotin is approximately 30 μg per day. Low-moderate dose biotin is a common component of multivitamin preparations, and high-dose biotin (10 000 times RDI) has been reported to improve clinical outcomes and quality of life in patients with progressive multiple sclerosis. Biotin is also a component of immunoassays, and supplementation may cause interference in both thyroid and non-thyroid immunoassays. To assess whether biotin ingestion caused abnormal thyroid function tests (TFTs) in a patient through assay interference. We report a patient with biotin-associated abnormal TFTs and a systematic review of the literature. A tertiary endocrine service in Hamilton, New Zealand. The patient had markedly abnormal TFTs that did not match the clinical context. After biotin cessation, TFTs normalized far more rapidly than possible given the half-life of T4, consistent with assay interference by biotin. Multiple other analytes also tested abnormal in the presence of biotin. Biotin ingested in moderate to high doses can cause immunoassay interference. Depending on the assay format, biotin interference can result in either falsely high or low values. Interference is not limited to thyroid tests and has the potential to affect a wide range of analytes. It is important for clinicians to be aware of this interaction to prevent misdiagnosis and inappropriate treatment.

  2. Nitrocellulose membrane-based enzyme-linked immunoassay for dengue serotype-1 IgM detection

    International Nuclear Information System (INIS)

    Leon, S.; Guevara, C.; Chunga, A.

    1999-01-01

    To evaluate the sensitivity and specifity of a nitrocellulose membrane-based immunoassay for dengue IgM, with respect to capture enzyme immunoassay, for the diagnosis of dengue virus infection. 101 serum samples were processed and divided into 2 groups: 53 from dengue serotype 1 (DEN1) infected patients, and 48 from healthy subjects. Both groups were tested with a nitrocellulose membrane-based IgM capture enzyme immunoassay (NMB-EIA) and also with an ELISA as referential pattern. NMB-EIA testing detected IgM anti-DEN1 in 94,34% of samples from infected patients, and in 14,58% of control samples, whereas ELISA fails to report false positive or false negative results: NMB-EIA appears to be a good alternative for dengue infection diagnosis. (authors)

  3. Rapid detection of fungal alpha-amylase in the work environment with a lateral flow immunoassay

    NARCIS (Netherlands)

    Bogdanovic, J.; Koets, M.; Sander, I.; Wouters, I.; Meijster, T.; Heederik, D.J.J.; Amerongen, van A.; Doekes, G.

    2006-01-01

    Background Occupational allergen exposure assessment usually requires airborne dust sampling at the worksite followed by dust extraction and enzyme immunoassay (EIA) analysis at the laboratory. Use of semiquantitative lateral flow immunoassays (LFIAs) may allow a more rapid detection procedure with

  4. Immunoassay separation technique

    International Nuclear Information System (INIS)

    1977-01-01

    A method for effecting the immunoassay of a multiplicity of samples, each possibly containing an antigen or an antibody to be assayed, is discussed. Each sample is incubated with a solution containing a detectable antigen or antibody to form a multiplicity of mixtures, each mixture containing as components antigen-antibody, non-complexed antigen and non-complexed antibody. At least one of the components of the said mixture is separated by adsorption. There after, quantity of detectable antigen or antibody is detected in one of the non-adsorbed portions of the mixture. An improvement, compared to other techniques, is the continuous and sequential separation of at least one component, which is intended to be separated from each said multiplicity of mixtures

  5. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin, E-mail: binhu@whu.edu.cn

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L{sup −1} and 0.054 μg L{sup −1} with the relative standard deviations (RSDs, n = 7, c = 5 μg L{sup −1}) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2–50 μg L{sup −1}. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications. - Highlights: • 4-Mercaptophenylboronic acid functionalized magnetic beads were prepared and characterized. • ICP-MS based magnetic immunoassay approach was developed for quantification of glycoproteins. • AFP and CEA were quantified simultaneously with Au and Ag NPs as element tags. • The developed method exhibited good selectivity and sensitivity for target glycoproteins.

  6. Feasibility of a simple microsieve-based immunoassay platform

    NARCIS (Netherlands)

    Zweitzig, D.R.; Tibbe, Arjan G.J.; Nguyen, A.T.; van Rijn, C.J.M.; Kopnitsky, M.J.; Cichonski, K.; Terstappen, Leonardus Wendelinus Mathias Marie

    2016-01-01

    The intrinsic properties of silicon microsieves, such as an optically flat surface, high overall porosity, and low flow resistance have led to an increasing number of biotechnology applications. In this report, the feasibility of creating a microsieve-based immunoassay platform was explored.

  7. Feasibility of a simple microsieve-based immunoassay platform

    NARCIS (Netherlands)

    Zweitzig, Daniel R.; Tibbe, Arjan G.; Nguyen, Ai T.; Rijn, van Cees J.M.; Kopnitsky, Mark J.; Cichonski, Kathleen; Terstappen, Leon W.M.M.

    2016-01-01

    The intrinsic properties of silicon microsieves, such as an optically flat surface, high overall porosity, and low flow resistance have led to an increasing number of biotechnology applications. In this report, the feasibility of creating a microsieve-based immunoassay platform was explored.

  8. Alkaline phosphatase-fused repebody as a new format of immuno-reagent for an immunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo-Deok; Lee, Joong-jae [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of); Kim, Yu Jung [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Hantschel, Oliver [School of Life Sciences, École Polytechnique Fédérale de Lausanne (EPFL), Lausanne (Switzerland); Lee, Seung-Goo [Industrial Biotechnology and Bioenergy Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon (Korea, Republic of); Kim, Hak-Sung, E-mail: hskim76@kaist.ac.kr [Department of Biological Sciences, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of)

    2017-01-15

    Enzyme-linked immunoassays based on an antibody-antigen interaction are widely used in biological and medical sciences. However, the conjugation of an enzyme to antibodies needs an additional chemical process, usually resulting in randomly cross-linked molecules and a loss of the binding affinity and enzyme activity. Herein, we present the development of an alkaline phosphatase-fused repebody as a new format of immuno-reagent for immunoassays. A repebody specifically binding to human TNF-α (hTNF-α) was selected through a phage display, and its binding affinity was increased up to 49 nM using a modular engineering approach. A monomeric alkaline phosphatase (mAP), which was previously isolated from a metagenome library, was genetically fused to the repebody as a signal generator, and the resulting repebody-mAP fusion protein was used for direct and sandwich immunoassays of hTNF-α. We demonstrate the utility and potential of the repebody-mAP fusion protein as an immuno-reagent by showing the sensitivity of 216 pg mL{sup −1} for hTNF-α in a sandwich immunoassay. Furthermore, this repebody-mAP fusion protein enabled the detection of hTNF-α spiked in a serum-supplemented medium with high accuracy and reproducibility. It is thus expected that a mAP-fused repebody can be broadly used as an immuno-reagent in immunoassays. - Highlights: • A human TNF-α (hTNF-α)-specific repebody was selected using a phage display. • A monomeric alkaline phosphatase (mAP) was genetically fused to the repebody. • mAP-fused repebody enabled detection of hTNF-α with high sensitivity and accuracy. • mAP-fused repebody can be widely used as a new immuno-reagent in immunoassays.

  9. Study on the determination of human placental lactogen (HPL) using an enzyme-immunoassay. Comparison with a commercial radio-immunoassay in the course of normal pregnancies

    International Nuclear Information System (INIS)

    Schneider, B.

    1982-01-01

    A novel enzyme-immunoassay (EIA) for determining human placental lactogen (HPL) was studied for its practicability and quality. The precision of the system in series was tested by using a serum taken each in the 19th, 29th and 40th pregnancy week. A normal range graph between the 10th and the 40th pregnancy week (10 sera per pregnancy week) was established from 310 sera of normal-course pregnancies. The graph practically agreed with the known RIA-established graphs. When comparing with a radio-immunoassay for HPL of routine application and known quality criteria, r=0.93 indicated a close correlation of the values found. (orig./MG) [de

  10. Evaluation of six immunoassays for detection of dengue virus-specific immunoglobulin M and G antibodies

    NARCIS (Netherlands)

    J. Groen (Jan); P. Koraka (Penelope); J. Velzing (Jans); C. Copra (Cederick); A.D.M.E. Osterhaus (Albert)

    2000-01-01

    textabstractThe performance of six commercially available immunoassay systems for the detection of dengue virus-specific immunoglobulin M (IgM) and IgG antibodies in serum was evaluated. These included two IgM and IgG enzyme immunoassays (EIA) from MRL Laboratories and PanBio, a rapid

  11. An Inexpensive, Fast and Sensitive Quantitative Lateral Flow Magneto-Immunoassay for Total Prostate Specific Antigen

    Directory of Open Access Journals (Sweden)

    Jacqueline M. Barnett

    2014-07-01

    Full Text Available We describe the detection characteristics of a device the Resonant Coil Magnetometer (RCM to quantify paramagnetic particles (PMPs in immunochromatographic (lateral flow assays. Lateral flow assays were developed using PMPs for the measurement of total prostate specific antigen (PSA in serum samples. A detection limit of 0.8 ng/mL was achieved for total PSA using the RCM and is at clinically significant concentrations. Comparison of data obtained in a pilot study from the analysis of serum samples with commercially available immunoassays shows good agreement. The development of a quantitative magneto-immunoassay in lateral flow format for total PSA suggests the potential of the RCM to operate with many immunoassay formats. The RCM has the potential to be modified to quantify multiple analytes in this format. This research shows promise for the development of an inexpensive device capable of quantifying multiple analytes at the point-of-care using a magneto-immunoassay in lateral flow format.

  12. A fast universal immobilization of immunoglobulin G at 4 °C for the development of array-based immunoassays.

    Directory of Open Access Journals (Sweden)

    Shu-Lin Guo

    Full Text Available To maintain the antibody activity and enhance performance of array-based immunoassays, protein G was used to allow a shorter duration of immunoglobulin G immobilization at 4 °C, with the antibody placed in the appropriate orientation. The multiplexed detection of six pain-related message molecules (PRMMs was used as examples for the development of array-based immunoassays: substance P, calcitonin gene-related peptide, nerve growth factor, brain-derived neurotrophic factor, tumor necrosis factor-α, and β-endorphin. Protein G- and non-protein G-coated slides were tested. Compared to non-protein G immunoassays, protein G shortened the antibody immobilization time at 4 °C from overnight to 2 hours. Only protein G-facilitated immunoassays succeeded in simultaneously detecting all six PRMMs with high specificity. Dose-response curves showed that the limits of detection of the protein G-multiplexed immunoassays for the PRMMs was approximately 164, 167, 120, 60, 80, and 92 pg/ml, respectively. Thus, protein G effectively shortens the duration of antibody immobilization at 4 °C, allowing the use of sensitive array-based immunoassays for the simultaneous detection of PRMMs.

  13. The development and current status of the technology of isotope and radiation in China

    Energy Technology Data Exchange (ETDEWEB)

    Jinrong, Z. [China Institute of Atomic Energy, Beijing, (China). Department of Isotopes

    1997-10-01

    The research and applications of isotope technology and radiation sources in China are presented. Many effort were directed towards production of radiopharmaceuticals, radiation sources, radiation treatment and radioactive tracers. Reactor and accelerator produced radioisotopes contributed to and will further accelerate the development of nuclear medicine in China. Recently, much attention has been paid on tumor therapy mainly with radiolabelled monoclonal antibody, radiolabelled microsphere and colloid, bone-seeking agents, and radiolabelled Octreotide. Radioimmunoassay has been widely used with many convenient kits available. There are above 30 radioimmunoassay kit produces and more than 60 radioimmunoassay centers. Recently the advance is mainly in solid-phase separation process and in radioimmunoassay method, including some nonradioactive immunoassay methods, such as enzyme immunoassay, fluorescence immunoassay, and chemiluminescence immunoassay. Kits for enzyme immunoassay have been put into clinical use. Various radiation sources are produced for medical purposes and for use in nuclear power stations 4 refs., 8 tabs.

  14. The development and current status of the technology of isotope and radiation in China

    International Nuclear Information System (INIS)

    Jinrong, Z.

    1997-01-01

    The research and applications of isotope technology and radiation sources in China are presented. Many effort were directed towards production of radiopharmaceuticals, radiation sources, radiation treatment and radioactive tracers. Reactor and accelerator produced radioisotopes contributed to and will further accelerate the development of nuclear medicine in China. Recently, much attention has been paid on tumor therapy mainly with radiolabelled monoclonal antibody, radiolabelled microsphere and colloid, bone-seeking agents, and radiolabelled Octreotide. Radioimmunoassay has been widely used with many convenient kits available. There are above 30 radioimmunoassay kit produces and more than 60 radioimmunoassay centers. Recently the advance is mainly in solid-phase separation process and in radioimmunoassay method, including some nonradioactive immunoassay methods, such as enzyme immunoassay, fluorescence immunoassay, and chemiluminescence immunoassay. Kits for enzyme immunoassay have been put into clinical use. Various radiation sources are produced for medical purposes and for use in nuclear power stations

  15. An ultrasensitive chemiluminescence immunoassay of chloramphenicol based on gold nanoparticles and magnetic beads.

    Science.gov (United States)

    Tao, Xiaoqi; Jiang, Haiyang; Yu, Xuezhi; Zhu, Jinghui; Wang, Xia; Wang, Zhanhui; Niu, Lanlan; Wu, Xiaoping; Shen, Jianzhong

    2013-05-01

    A competitive, direct, chemiluminescent immunoassay based on a magnetic beads (MBs) separation and gold nanoparticles (AuNPs) labelling technique to detect chloramphenicol (CAP) has been developed. Horseradish peroxidase (HRP)-labelled anti-CAP monoclonal antibody conjugated with AuNPs and antigen-immobilized MBs were prepared. After optimization parameters of immunocomplex MBs, the IC50 values of chemiluminescence magnetic nanoparticles immunoassay (CL-MBs-nano-immunoassay) were 0.017 µg L(-1) for extract method I and 0.17 µg L(-1) for extract method II. The immunoassay with two extract methods was applied to detect CAP in milk. Comparison of these two extract methods showed that extract method I was advantageous in better sensitivity, in which the sensitivity was 10 times compared to that of extract method II, while extract method II was superior in simple operation, suitable for high throughout screen. The recoveries were 86.7-98.0% (extract method I) and 80.0-103.0% (extract method II), and the coefficients of variation (CVs) were all recovery with both extract methods and high correlation with traditional ELISA kit in milk system confirmed that the immunomagnetic assay based on AuNPs exhibited promising potential in rapid field screening for trace CAP analysis. Copyright © 2013 John Wiley & Sons, Ltd.

  16. Dot immunoassay for the simultaneous determination of postvaccination immunity against pertussis, diphtheria, and tetanus.

    Science.gov (United States)

    Khramtsov, Pavel; Bochkova, Maria; Timganova, Valeria; Zamorina, Svetlana; Rayev, Mikhail

    2017-06-01

    A dot immunoassay for simultaneous semiquantitative detection of IgG against tetanus toxoid (Ttx) and diphtheria toxoid (Dtx) and qualitative detection of anti-Bordetella pertussis IgGs in human blood serum using carbon nanoparticles functionalized with streptococcal protein G was developed. Inactivated B. pertussis cells in suspension form were used as an antigen in the immunoassay. Pertussis, tetanus, and diphtheria antigens were separately spotted onto nitrocellulose strips, and then the immunostrips were successively incubated with blood sera and a suspension of carbon nanoparticles. The immunostrips were then scanned with a flatbed scanner, and the images obtained were processed with ImageJ. One hundred fifty-five venous blood serum samples from children vaccinated with diphtheria, tetanus, and whole-cell pertussis (DTwP) vaccine were tested in comparison with a conventional ELISA and agglutination test. The total time required for analysis of 32 serum samples was less than 3 h. Comparison between the results of the dot immunoassay and the corresponding ELISA/agglutination test revealed a high level of agreement (Cohen's kappa between 0.765 and 0.813). The lower limit of quantification was 0.06 IU/ml for anti-Ttx and anti-Dtx. The intra-assay coefficients of variation were less than 15% for anti-Ttx and anti-Dtx and less than 10% for anti-pertussis. The diagnostic sensitivity of detection of the antibody protection level was 93.5% for anti-Ttx [95% confidence interval (CI) 83.5-97.9%], 92.4% for anti-Dtx (95% CI 80.9297.5%), and 90.2% for anti-pertussis (95% CI 75.9-96.8%). The diagnostic specificity was 90.9% for anti-Ttx (95% CI 57.1-99.5%), 85% for anti-Dtx (95% CI 61.1-96.0%), and 89.3% for anti-pertussis (95%CI 80.8-94.5%). The dot immunoassay developed does not require expensive reading equipment, and allows detection of antibodies against three antigens in a single analysis. The immunostrips can be stored for a long time without changes in the

  17. Comparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay

    International Nuclear Information System (INIS)

    Castro, A.; Ibanez, J.; DiCesare, J.L.; Adams, R.F.; Malkus, H.

    1978-01-01

    Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoasay, enzyme immunoassay, and liquid chromatography. The assay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatography. Our radioimmunoassay data correlated poorly with results by the four other methods

  18. Studies on direct and indirect electrochemical immunoassays

    OpenAIRE

    Buckley, Eileen

    1989-01-01

    Two approaches to electrochemical immunoassay are reported. The first approach was an indirect method, involving an electroactive, enzyme-catalysed, substrate to product reaction. Conditions were optimised for the amperometric detection of para-aminophenol, the electroactive product of the alkaline phosphatase catalysed hydrolysis of a new substrate, p-aminophenylphosphate, after separation by HPLC. The second approach involved the direct electrochemical detection of an immunoglo...

  19. Which amphetamine-type stimulants can be detected by oral fluid immunoassays?

    Science.gov (United States)

    Souza, Daniele Z; Boehl, Paula O; Comiran, Eloisa; Prusch, Débora S; Zancanaro, Ivomar; Fuentefria, Alexandre M; Pechansky, Flavio; Duarte, Paulina C A V; De Boni, Raquel B; Fröehlich, Pedro E; Limberger, Renata P

    2012-02-01

    The use of oral fluid for monitoring drug consumption on roads has many advantages over conventional biological fluids; therefore, several immunoassays have been developed for this purpose. In this work, the ability of 3 commercial immunoassays to detect amphetamine-type stimulants (ATSs) in oral fluid was assessed. In addition, it was reviewed the main controlled ATSs available worldwide, as well as the oral fluid immunological screening tests that have been used for identifying ATSs in drivers. The analytical specificity of amphetamine direct enzyme-linked immunosorbent assay (ELISA), methamphetamine direct ELISA (Immunalysis Corporation), and Oral-View saliva multidrug of abuse test (Alfa Scientific Designs) was evaluated using ATS-spiked oral fluid. Legislation and published articles that report the use of immunological screening tests to detect ATS consumption in conductors were reviewed, including the kit's technical information, project reports, police and drug databases. Even at high concentrations, the tested assays were not able to detect methylphenidate, fenproporex, or diethylpropion, controlled ATSs legally marketed in many countries. This evidences the need to develop new kits that enable one to control the misuse of prescription ATSs on roads through oral fluid immunoassays.

  20. Plasmon enhanced fluoro-immunoassay using egg yolk antibodies for ultra-sensitive detection of herbicide diuron.

    Science.gov (United States)

    Sharma, Priyanka; Kukkar, Manil; Ganguli, Ashok K; Bhasin, Aman; Suri, C Raman

    2013-08-07

    Plasmon enhanced fluorescence immunoassay (PEFI) format has been reported in developing a sensitive heterogeneous fluoroimmunoassay for monitoring the phenylurea herbicide diuron. Computer-assisted molecular modeling was carried out to study the conformational and electrostatic effects of synthesized hapten for producing highly specific egg yolk antibody against a phenyl urea herbicide diuron. The generated antibodies were labeled with fluorescein isothiocyanate at different molar ratios and used as tracer in the developed fluorescence based immunoassay. The sensitivity of the assay format was enhanced by using silver nanoparticles tagged with bovine serum albumin as a new blocking reagent in the developed PEFI format. Enhancer treatment on the developed immunoassay showed a significant improvement of fluorescence signal intensity with approximately 10 fold increase in assay sensitivity. The immunoassay has a detection limit of 0.01 ng mL(-1) with good signal precision (~2%) in the optimum working concentration range between 1 pg mL(-1) to 10 μg mL(-1) of diuron. These findings facilitate high throughput fluorescence-based processes that could be useful in biology, drug discovery and compound screening applications.

  1. The management of isolated positive syphilis enzyme immunoassay results in HIV-negative patients attending a sexual health clinic.

    Science.gov (United States)

    Thorley, Nicola; Adebayo, Michael; Smit, Erasmus; Radcliffe, Keith

    2016-08-01

    An unconfirmed positive treponemal enzyme immunoassay (enzyme immunoassay positive, Treponema pallidum particle agglutination negative and rapid plasma reagin negative) presents a clinical challenge to distinguish early syphilis infection from false-positive results. These cases are referred for syphilis line assay (INNO-LIA) and recalled for repeat syphilis serology. We performed a retrospective audit to establish the proportion of HIV-negative cases with unconfirmed positive enzyme immunoassay results, the proportion of these cases that received an INNO-LIA test and repeat syphilis serology testing and reviewed the clinical outcomes; 0.35% (80/22687) cases had an unconfirmed positive treponemal enzyme immunoassay result. Repeat syphilis serology was performed in 80% (64/80) cases, but no additional cases of syphilis were identified. Eighty-eight per cent (70/80) received an INNO-LIA test; 14% (5/37) unconfirmed enzyme immunoassay-positive cases with no prior history of syphilis were confirmed on INNO-LIA assay, supporting a diagnosis of latent syphilis. As a confirmatory treponemal test, the INNO-LIA assay may be more useful than repeat syphilis serological testing. © The Author(s) 2016.

  2. Chemiluminescence immunoassay based on dual signal amplification strategy of Au/mesoporous silica and multienzyme functionalized mesoporous silica

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jiehua, E-mail: linjiehua@qust.edu.cn [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China); Zhao Yue; Wei Zhijing; Wang Wei [Key Laboratory of Eco-chemical Engineering, Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042 (China)

    2011-11-15

    Highlights: > The increased amount of monoclonal antibody in Au/SiO{sub 2} led to a wider linear range. > Due to the increased HRP tags in HRP-Ab{sub 2}/SiO{sub 2}, signal amplification achieved. > A simple dual amplification immunoassay achieved with flow injection analysis. - Abstract: A chemiluminescent dual signal amplification strategy for the determination of {alpha}-fetoprotein (AFP) was proposed based on a sandwich immunoassay format. Monoclonal antibody of AFP immobilized on the gold nanoparticles doped mesoporous SiO{sub 2} (Au/SiO{sub 2}) were prepared and used as a primary antibody. Horseradish peroxidase (HRP) and HRP-labeled secondary antibody (Ab{sub 2}) co-immobilized into the mesoporous SiO{sub 2} nanoparticles (HRP-Ab{sub 2}/SiO{sub 2}) were used as the labeled immunological probe. Due to the high ratio surface areas and pore volumes of the mesoporous SiO{sub 2}, not only the amount of AFP monoclonal antibody but also the amount of the modified HRP and Ab{sub 2} in HRP-Ab{sub 2}/SiO{sub 2} were largely increased. Thus the chemiluminescent signal was amplified by using the system of luminol and H{sub 2}O{sub 2} under the catalysis of HRP. Under the optimal conditions, two linear ranges for AFP were obtained from 0.01 to 0.5 ng mL{sup -1} and 0.5 to 100 ng mL{sup -1} with a detection limit of 0.005 ng mL{sup -1} (3{sigma}). The fabricated signal amplification strategy showed an excellent promise for sensitive detection of AFP and other tumor markers.

  3. Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay

    Directory of Open Access Journals (Sweden)

    Orazio Ruzzenente

    2016-12-01

    Full Text Available Objectives: This study was designed to evaluate the analytical performance of the novel Lumipulse G1200 BRAHMS procalcitonin (PCT immunoassay. Design and methods: This analytical evaluation encompassed the calculation of the limit of blank (LOB, limit of detection (LOD, functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the Vidas BRAHMS PCT assay. Results: The LOB, LOD and functional sensitivity were 0.0010 ng/mL, 0.0016 ng/mL and 0.008 ng/mL, respectively. The total analytical imprecision was found to be 2.1% and the linearity was excellent (r=1.00 in the range of concentrations between 0.006–75.5 ng/mL. The correlation coefficient with Vidas BRAHMS PCT was 0.995 and the equation of the Passing and Bablok regression analysis was [Lumipulse G BRAHMS PCT]=0.76×[Vidas BRAHMS PCT]+0.04. The mean overall bias of Lumipulse G BRAHMS PCT versus Vidas BRAHMS PCT was −3.03 ng/mL (95% confidence interval [CI]: −4.32 to −1.74 ng/mL, whereas the mean bias in samples with PCT concentration between 0–10 ng/mL was −0.49 ng/mL (95% CI: −0.77 to −0.24 ng/mL. The diagnostic agreement was 100% at 0.5 ng/mL, 97% at 2.0 ng/mL and 95% at 10 ng/mL, respectively. Conclusions: These results attest that Lumipulse G BRAHMS PCT exhibits excellent analytical performance, among the best of the methods currently available on the diagnostic market. However, the significant bias compared to the Vidas BRAHMS PCT suggests that the methods cannot be used interchangeably. Keywords: Sepsis, Infection, Procalcitonin, Immunoassay

  4. Deoxynivalenol-mimic nanobody isolated from a naïve phage display nanobody library and its application in immunoassay.

    Science.gov (United States)

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Bhunia, Arun K; Tu, Zhui; Chen, Bo; Liu, Yuan-Yuan

    2015-08-05

    In this study, using mycotoxin deoxynivalenol (DON) as a model hapten, we developed a nanobody-based environmental friendly immunoassay for sensitive detection of DON. Two nanobodies (N-28 and N-31) which bind to anti-DON monoclonal antibody (MAb) were isolated from a naive phage display library. These nanobodies are clonable, thermally stable and mycotoxin-free products and can be served as coating antigen mimetics in heterologous immunoassay. The half inhibition concentration (IC50) of the immunoassay developed with N-28 and N-31 was 8.77 ± 0.41 ng mL(-1) and 19.97 ± 0.84 ng mL(-1), respectively, which were 18- and 8-fold more sensitive than the conventional coating antigen (DON-BSA) based immunoassay. In order to better understand the molecular mechanism of antigen mimicry by nanobody, the 3D structure of "nanobody (N-28) - anti-DON MAb" complex was presented and verified by molecular modeling and alanine-scanning mutagenesis. The results showed that hydrogen bond and hydrophobic interaction formed between Thr 102 - Ser 106 of N-28 and CDR H3 residues of anti-DON antibody may contribute to their binding. This novel concept of enhancing sensitivity of immunoassay for DON based on nanobody may provide potential applications in a general method for immunoassay of various food chemical contaminants. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries.

    Science.gov (United States)

    Pilavaki, Evdokia; Demosthenous, Andreas

    2017-11-20

    Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.

  6. Optimized Lateral Flow Immunoassay Reader for the Detection of Infectious Diseases in Developing Countries

    Directory of Open Access Journals (Sweden)

    Evdokia Pilavaki

    2017-11-01

    Full Text Available Detection and control of infectious diseases is a major problem, especially in developing countries. Lateral flow immunoassays can be used with great success for the detection of infectious diseases. However, for the quantification of their results an electronic reader is required. This paper presents an optimized handheld electronic reader for developing countries. It features a potentially low-cost, low-power, battery-operated device with no added optical accessories. The operation of this proof of concept device is based on measuring the reflected light from the lateral flow immunoassay and translating it into the concentration of the specific analyte of interest. Characterization of the surface of the lateral flow immunoassay has been performed in order to accurately model its response to the incident light. Ray trace simulations have been performed to optimize the system and achieve maximum sensitivity by placing all the components in optimum positions. A microcontroller enables all the signal processing to be performed on the device and a Bluetooth module allows transmission of the results wirelessly to a mobile phone app. Its performance has been validated using lateral flow immunoassays with influenza A nucleoprotein in the concentration range of 0.5 ng/mL to 200 ng/mL.

  7. IMMUNOASSAYS FOR THE DETECTION OF UROKINASE RECEPTOR FORMS

    DEFF Research Database (Denmark)

    2004-01-01

    amounts of uPAR forms in a sample with data indicative of the presence of the cancer disease. The method can be used for staging, prognosis or diagnosis of prostate cancer. Two novel monoclonal antibodies and a kit and immunoassays for detecting at least one uPAR form(s) are also described in the present...

  8. Direct salivary cortisol radio-immunoassay determination. Clinical applications

    International Nuclear Information System (INIS)

    Simon, C.; Cherfan, J.; Kurtz, F.; Vignon, F.; Schlienger, J.L.; Chabrier, G.

    1987-01-01

    Salivary cortisol levels reflect the biologically active free fraction of blood cortisol. The authors describe the results obtained with the aim of a radio-immunoassay commercial serum cortisol kit, without prealable extraction in different physiological and pathological situations. Salivary cortisol determination appears performant both in nycthemeral studies and in stimulation or freination tests [fr

  9. A sandwich immunoassay for human prolyl 4-hydroxylase using monoclonal antibody

    International Nuclear Information System (INIS)

    Yoshida, Shinichi

    1986-01-01

    Monoclonal antibody was used in a sandwich enzyme immunoassay and in a radioimmunoassay for human serum immunoreactive prolyl 4-hydroxylase. The enzyme immunoassay utilized a monoclonal antibody as a solid phase and horseradish peroxidase-labeled rabbit antibody to human prolyl 4-hydroxylase as a conjugate. Sensitivity was 0.1 ng of enzyme per tube. With a conjugate purified by an enzyme-bound affinity column, sensitivity was increased to 0.01 ng per tube, and linearity was obtained between 0.01 to 30 ng per tube. The radioimmunoassay used a 125 I-labeled rabbit antibody (IgG) as the conjugate. Sensitivity of this technique was 0.4 ng of enzyme per tube. (Auth.)

  10. Immunoassay of β-endorphin

    International Nuclear Information System (INIS)

    Hoellt, V.; Gramsch, C.; Herz, A.

    1979-01-01

    The present paper describes the characteristics of a series of antisera against β-endorphin (β-E) developed in our laboratory which all recognize β-lipotropin and their use in (1) the determination of β-E in tissue and in body fluids and in (2) the immunocytochemical localization of β-E containing neurons in the rat brain and in (3) the study of the conversion of the β-E/β-LPH precursor into β-LPH and β-E in the pars intermedia/nervosa of the rat pituitary. It is the purpose of the present report to critically analyze the pitfalls and drawbacks, as well as the advantage, of the use of radioimmunoassay and other immunoassays in the determination of β-E. (Auth.)

  11. Ultrasensitive and accelerated detection of ciguatoxin by capillary electrophoresis via on-line sandwich immunoassay with rotating magnetic field and nanoparticles signal enhancement.

    Science.gov (United States)

    Zhang, Zhaoxiang; Zhang, Chaoying; Luan, Wenxiu; Li, Xiufeng; Liu, Ying; Luo, Xiliang

    2015-08-12

    A sensitive and rapid on-line immunoassay for the determination of ciguatoxin CTX3C was developed based on a capillary mixing system, which was integrated with capillary electrophoresis (CE) separation and electrochemical (EC) detection. In the sandwich immunoassay system, anti-CTX3C-functionalized magnetic nanoparticles were used as immunosensing probes, and horseradish peroxidase (HRP) and anti-CTX3C antibody were bound onto the surface of gold nanoparticles (AuNPs) and used as recognition elements. Online formation of immunocomplex was realized in capillary inlet end with an external rotating magnetic field. Compared with classical HPLC-MS and ELISA, the assay adopting AuNPs as multienzyme carriers and online sandwich immunoassay format with rotating magnetic field exhibited higher sensitivity and shorter assay time. The linear range of the assay for CTX3C was from 0.6 to 150 ng/L with a correlation coefficient of 0.9948 (n = 2), and the detection limit (S/N = 3) was 0.09 ng/L. The developed assay showed satisfying reproducibility and stability, and it was successfully applied for the quantification of CTX3C in fish samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Towards the development of a radioenzyme-immunoassay

    International Nuclear Information System (INIS)

    Schuurs, A.H.W.M.; Waart, M. v. d.

    1976-01-01

    We have tried to develop a very sensitive enzyme-immunoassay. For this purpose, a very sensitive radiochemical enzyme assay was used. HCG was chosen as test model and AChE as labelling enzyme. The test appeared to be much more sensitive than the normal enzymeimmunoassay. And, in comparison with RIA, it was about as sensitive but less time-consuming, and it makes use, in principle, of stable reagents. (orig./GSE) [de

  13. Modification of a deoxynivalenol-antigen-mimicking nanobody to improve immunoassay sensitivity by site-saturation mutagenesis.

    Science.gov (United States)

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Wang, Wei; Liu, Yuan-Yuan

    2016-01-01

    A nanobody (N-28) which can act as a deoxynivalenol (DON) antigen has been generated, and its residues Thr102-Ser106 were identified to bind with anti-DON monoclonal antibody by alanine-scanning mutagenesis. Site-saturation mutagenesis was used to analyze the plasticity of five residues and to improve the sensitivity of the N-28-based immunoassay. After mutagenesis, three mutants were selected by phage immunoassay and were sequenced. The half-maximal inhibitory concentrations of the immunoassay based on mutants N-28-T102Y, N-28-V103L, and N-28-Y105F were 24.49 ± 1.0, 51.83 ± 2.5, and 35.65 ± 1.6 ng/mL, respectively, showing the assay was, respectively, 3.2, 1.5, and 2.2 times more sensitive than the wild-type-based assay. The best mutant, N-28-T102Y, was used to develop a competitive phage ELISA to detect DON in cereals with high specificity and accuracy. In addition, the structural properties of N-28-T102Y and N-28 were investigated, revealing that the affinity of N-28-T102Y decreased because of increased steric hindrance with the large side chain. The lower-binding-affinity antigen mimetic may contribute to the improvement of the sensitivity of competitive immunoassays. These results demonstrate that nanobodies would be a favorable tool for engineering. Moreover, our results have laid a solid foundation for site-saturation mutagenesis of antigen-mimicking nanobodies to improve immunoassay sensitivity for small molecules.

  14. Monoclonal antibody technologies and rapid detection assays

    Science.gov (United States)

    Novel methodologies and screening strategies will be outlined on the use of hybridoma technology for the selection of antigen specific monoclonal antibodies. The development of immunoassays used for diagnostic detection of prions and bacterial toxins will be discussed and examples provided demonstr...

  15. Dual-Mode SERS-Fluorescence Immunoassay Using Graphene Quantum Dot Labeling on One-Dimensional Aligned Magnetoplasmonic Nanoparticles.

    Science.gov (United States)

    Zou, Fengming; Zhou, Hongjian; Tan, Tran Van; Kim, Jeonghyo; Koh, Kwangnak; Lee, Jaebeom

    2015-06-10

    A novel dual-mode immunoassay based on surface-enhanced Raman scattering (SERS) and fluorescence was designed using graphene quantum dot (GQD) labels to detect a tuberculosis (TB) antigen, CFP-10, via a newly developed sensing platform of linearly aligned magnetoplasmonic (MagPlas) nanoparticles (NPs). The GQDs were excellent bilabeling materials for simultaneous Raman scattering and photoluminescence (PL). The one-dimensional (1D) alignment of MagPlas NPs simplified the immunoassay process and enabled fast, enhanced signal transduction. With a sandwich-type immunoassay using dual-mode nanoprobes, both SERS signals and fluorescence images were recognized in a highly sensitive and selective manner with a detection limit of 0.0511 pg mL(-1).

  16. Discordant Analytical Results Caused by Biotin Interference on Diagnostic Immunoassays in a Pediatric Hospital.

    Science.gov (United States)

    Ali, Mahesheema; Rajapakshe, Deepthi; Cao, Liyun; Devaraj, Sridevi

    2017-09-01

    Recent studies have reported that biotin interferes with certain immunoassays. In this study, we evaluated the analytical interference of biotin on immunoassays that use streptavidin-biotin in our pediatric hospital. We tested the effect of different concentrations of biotin (1.5-200 ng/ml) on TSH, Prolactin, Ferritin, CK-MB, β-hCG, Troponin I, LH, FSH, Cortisol, Anti-HAV antibody (IgG and IgM), assays on Ortho Clinical Diagnostic Vitros 5600 Analyzer. Biotin (up to 200 ng/mL) did not significantly affect Troponin I and HAV assays. Biotin (up to 12.5 ng/ml) resulted in biotin >6.25 ng/mL significantly affected TSH (>20% bias) assay. Prolactin was significantly affected even at low levels (Biotin 1.5 ng/mL). Thus, we recommend educating physicians about biotin interference in common immunoassays and adding an electronic disclaimer. © 2017 by the Association of Clinical Scientists, Inc.

  17. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays

    DEFF Research Database (Denmark)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter

    2016-01-01

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng....../L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED...... excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems....

  18. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays.

    Science.gov (United States)

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Petersen, Paul Michael; Pedersen, Christian

    2016-09-19

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flash lamp and the LED based system and discussed temporal, spatial, and spectral features of the LED excitation for time-resolved fluorimetry. Optimization of the suggested key parameters of the LED promises significant increase of the signal-to-noise ratio and hence of the sensitivity of immunoassay systems.

  19. [Automated analyzer of enzyme immunoassay].

    Science.gov (United States)

    Osawa, S

    1995-09-01

    Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.

  20. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: An anticipated analytical tool for food safety

    International Nuclear Information System (INIS)

    Hervas, Miriam; Lopez, Miguel Angel; Escarpa, Alberto

    2009-01-01

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 μg L -1 and EC 50 0.079 μg L -1 were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  1. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: an anticipated analytical tool for food safety.

    Science.gov (United States)

    Hervás, Miriam; López, Miguel Angel; Escarpa, Alberto

    2009-10-27

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 microg L(-1) and EC(50) 0.079 microg L(-1) were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  2. Electrochemical immunoassay using magnetic beads for the determination of zearalenone in baby food: An anticipated analytical tool for food safety

    Energy Technology Data Exchange (ETDEWEB)

    Hervas, Miriam; Lopez, Miguel Angel [Departamento Quimica Analitica, Universidad de Alcala, Ctra. Madrid-Barcelona, Km. 33600, E-28871 Alcala de Henares, Madrid (Spain); Escarpa, Alberto, E-mail: alberto.escarpa@uah.es [Departamento Quimica Analitica, Universidad de Alcala, Ctra. Madrid-Barcelona, Km. 33600, E-28871 Alcala de Henares, Madrid (Spain)

    2009-10-27

    In this work, electrochemical immunoassay involving magnetic beads to determine zearalenone in selected food samples has been developed. The immunoassay scheme has been based on a direct competitive immunoassay method in which antibody-coated magnetic beads were employed as the immobilisation support and horseradish peroxidase (HRP) was used as enzymatic label. Amperometric detection has been achieved through the addition of hydrogen peroxide substrate and hydroquinone as mediator. Analytical performance of the electrochemical immunoassay has been evaluated by analysis of maize certified reference material (CRM) and selected baby food samples. A detection limit (LOD) of 0.011 {mu}g L{sup -1} and EC{sub 50} 0.079 {mu}g L{sup -1} were obtained allowing the assessment of the detection of zearalenone mycotoxin. In addition, an excellent accuracy with a high recovery yield ranging between 95 and 108% has been obtained. The analytical features have shown the proposed electrochemical immunoassay to be a very powerful and timely screening tool for the food safety scene.

  3. Biosensor immunoassay for flumequine in broiler serum and muscle

    NARCIS (Netherlands)

    Haasnoot, W.; Gercek, H.; Cazemier, G.; Nielen, M.W.F.

    2007-01-01

    Flumequine (Flu) is one of the fluoroquinolones most frequently applied for the treatment of broilers in The Netherlands. For the detection of residues of Flu in blood serum of broilers, a biosensor immunoassay (BIA) was developed which was fast (7.5 min per sample) and specific (no cross-reactivity

  4. Analytical validation of Gentian NGAL particle-enhanced enhanced turbidimetric immunoassay (PETIA

    Directory of Open Access Journals (Sweden)

    Gian Luca Salvagno

    2017-08-01

    Full Text Available Objectives: This study was designed to validate the analytical performance of the new Gentian particle-enhanced enhanced turbidimetric immunoassay (PETIA for measuring neutrophil gelatinase-associated lipocalin (NGAL in serum samples. Design and methods: Analytical validation of the Gentian NGAL assay was carried out on a Roche Cobas c501 and was based on assessment of limit of blank (LOB, limit of detection (LOD, functional sensitivity, imprecision, linearity and concordance with the BioPorto NGAL test. Results: The LOB and LOD of Gentian NGAL were found to be 3.8 ng/mL and 6.3 ng/mL, respectively. An analytical coefficient of variation (CV of 20% corresponded to a NGAL value of 10 ng/mL. The intra-assay and inter-assay imprecision (CV was between 0.4 and 5.2% and 0.6 and 7.1% and the total imprecision (CV was 3.7%. The linearity was optimal at NGAL concentrations between 37 and 1420 ng/mL (r=1.00; p<0.001. An excellent correlation was observed between values measured with Gentian NGAL and BioPorto NGAL in 74 routine serum samples (r=0.993. The mean percentage bias of the Gentian assay versus the Bioporto assay was +3.1% (95% CI, +1.6% to +4.5%. Conclusions: These results show that Gentian NGAL may be a viable option to other commercial immunoassays for both routine and urgent assessment of serum NGAL. Keywords: Neutrophil gelatinase-associated lipocalin, NGAL, Analytical validation, Acute kidney injury

  5. Chimeric recombinant antibody fragments in cardiac troponin I immunoassay.

    Science.gov (United States)

    Hyytiä, Heidi; Heikkilä, Taina; Brockmann, Eeva-Christine; Kekki, Henna; Hedberg, Pirjo; Puolakanaho, Tarja; Lövgren, Timo; Pettersson, Kim

    2015-03-01

    To introduce a novel nanoparticle-based immunoassay for cardiac troponin I (cTnI) utilizing chimeric antibody fragments and to demonstrate that removal of antibody Fc-part and antibody chimerization decrease matrix related interferences. A sandwich-type immunoassay for cTnI based on recombinant chimeric (mouse variable/human constant) antigen binding (cFab) antibodies and intrinsically fluorescent nanoparticles was developed. To test whether using chimeric antibody fragments helps to avoid matrix related interferences, samples (n=39) with known amounts of triglycerides, bilirubin, rheumatoid factor (RF) or human anti-mouse antibodies (HAMAs) were measured with the novel assay, along with a previously published nanoparticle-based research assay with the same antibody epitopes. The limit of detection (LoD) was 3.30ng/L. Within-laboratory precision for 29ng/L and 2819ng/L cTnI were 13.7% and 15.9%, respectively. Regression analysis with Siemens ADVIA Centaur® yielded a slope (95% confidence intervals) of 0.18 (0.17-1.19) and a y-intercept of 1.94 (-1.28-3.91) ng/L. When compared to a previously published nanoparticle-based assay, the novel assay showed substantially reduced interference in the tested interference prone samples, 15.4 vs. 51.3%. A rheumatoid factor containing sample was decreased from 241ng/L to immunoassay for the detection of cTnI and decreased matrix related interferences, thus resulting in a lower number of falsely elevated cTnI-values. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Gliadin Detection in Food by Immunoassay

    Science.gov (United States)

    Grant, Gordon; Sporns, Peter; Hsieh, Y.-H. Peggy

    Immunoassays are very sensitive and efficient tests that are commonly used to identify a specific protein. Examples of applications in the food industry include identification of proteins expressed in genetically modified foods, allergens, or proteins associated with a disease, including celiac disease. This genetic disease is associated with Europeans and affects about one in every 200 people in North America. These individuals react immunologically to wheat proteins, and consequently their own immune systems attack and damage their intestines. This disease can be managed if wheat proteins, specifically "gliadins," are avoided in foods.

  7. Photonic ring resonance is a versatile platform for performing multiplex immunoassays in real time.

    Science.gov (United States)

    Mudumba, Sasi; de Alba, Sophia; Romero, Randy; Cherwien, Carli; Wu, Alice; Wang, Jue; Gleeson, Martin A; Iqbal, Muzammil; Burlingame, Rufus W

    2017-09-01

    Photonic ring resonance is a property of light where in certain circumstances specific wavelengths are trapped in a ring resonator. Sensors based on silicon photonic ring resonators function by detecting the interaction between light circulating inside the sensor and matter deposited on the sensor surface. Binding of biological material results in a localized change in refractive index on the sensor surface, which affects the circulating optical field extending beyond the sensor boundary. That is, the resonant wavelength will change when the refractive index of the medium around the ring resonator changes. Ring resonators can be fabricated onto small silicon chips, allowing development of a miniature multiplex array of ring based biosensors. This paper describes the properties of such a system when responding to the refractive index changed in a simple and precise way by changing the ionic strength of the surrounding media, and in a more useful way by the binding of macromolecules to the surface above the resonators. Specifically, a capture immunoassay is described that measures the change of resonant wavelength as a patient serum sample with anti-SS-A autoantibodies is flowed over a chip spotted with SS-A antigen and amplified with anti-IgG. The technology has been miniaturized and etched into a 4×6mm silicon chip that can measure 32 different reactions in quadruplicate simultaneously. The variability between 128 rings on a chip as measured by 2M salt assays averaged 0.6% CV. The output of the assays is the average shift per cluster of 4 rings, and the assays averaged 0.5% CV between clusters. The variability between chips averaged 1.8%. Running the same array on multiple instruments showed that after some improvements to the wavelength referencing system, the upper boundary of variation was 3% between 13 different instruments. The immunoassay displayed about 2% higher variability than the salt assays. There are several outstanding features of this system. The

  8. Multiplex dipstick immunoassay for semi-quantitative determination of Fusarium mycotoxins in cereals

    International Nuclear Information System (INIS)

    Lattanzio, Veronica M.T.; Nivarlet, Noan; Lippolis, Vincenzo; Gatta, Stefania Della; Huet, Anne-Catherine; Delahaut, Philippe; Granier, Benoit; Visconti, Angelo

    2012-01-01

    Highlights: ► We developed a rapid method based on a multiplex dipstick immunoassay. ► The assay allowed the determination of major Fusarium toxins in wheat, oats, maize. ► We obtained cut off levels close to EU regulatory levels. - Abstract: A multiplex dipstick immunoassay based method for the simultaneous determination of major Fusarium toxins, namely zearalenone, T-2 and HT-2 toxins, deoxynivalenol and fumonisins in wheat, oats and maize has been developed. The dipstick format was based on an indirect competitive approach. Four test lines (mycotoxin–BSA conjugates) and one control line were located on the strip membrane. Labelled antibodies were freeze-dried within the microwell. Two matrix-related sample preparation protocols have been developed for wheat/oats (not containing fumonisins) and maize (containing fumonisins) respectively. The use of a methanol/water mixture for sample preparation allowed recoveries in the range 73–109% for all mycotoxins in all tested cereals, with relative standard deviation less than 10%. The optimized immunoassay was able to detect target mycotoxins at cut off levels equal to 80% of EU maximum permitted levels, i.e. 280, 400, 1400 and 3200 μg kg −1 , respectively, for zearalenone, T-2/HT-2 toxins, deoxynivalenol and fumonisins in maize, and 80, 400 and 1400 μg kg −1 , respectively, for zearalenone, T-2/HT-2 toxins and deoxynivalenol in wheat and oats. Analysis of naturally contaminated samples resulted in a good agreement between multiplex dipstick and validated confirmatory LC–MS/MS. The percentage of false positive results was less than or equal to 13%, whereas no false negative results were obtained. Data on the presence/absence of 6 mycotoxins at levels close to EU regulatory levels were obtained within 30 min. The proposed immunoassay protocol is rapid, inexpensive, easy-to-use and fit for purpose of rapid screening of mycotoxins in cereals.

  9. Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement

    DEFF Research Database (Denmark)

    Campbell, Duncan J; Nussberger, Juerg; Stowasser, Michael

    2009-01-01

    into focus the differences in information provided by activity assays and immunoassays for renin and prorenin measurement and has drawn attention to the need for precautions to ensure their accurate measurement. CONTENT: Renin activity assays and immunoassays provide related but different information...... provided by these assays and of the precautions necessary to ensure their accuracy....

  10. Evaluation of four immunoassays for diagnosis of brucellosis in Cuba

    International Nuclear Information System (INIS)

    Peraza, C.; Valdes, O.; Fonseca, N.; Garcia, M.; Alvarez, M.; Izquierdo, D.L.

    1998-01-01

    Four immunoassays (two indirect and two competitive ones) were evaluated by samples from areas free of disease, free by vaccination and affected areas using as reference techniques the Bengal Rose Tests, the Antigen in Buffered Plate Tests and the Complement Fixation Reaction Test. The evaluated samples demonstrated that the competitive assays (ELISAC-1 and ELISAC-2) detected less false positives than the indirect ones (ELISAI-1 and ELISAI-2). Of the competitive ELISAS, version 2 presented better sensitivity and specificity results in affected areas for 95% confidence: 80.9 - 96.9% and 97.5 - 99.4% respectively with positive predictive value in the range of 76 to 94% and negative predictive one between 98.1 and 99.7%. It was concluded that this assay can be used for brucellosis control because it gives higher assurance than the other evaluated immunoassays and it can discriminate infected from vaccinated animals. (author)

  11. Determination of digoxin by enzyme immunoassay and radioimmunoassay

    International Nuclear Information System (INIS)

    Mueller, H.; Braeuer, H.; Foerster, G.; Reinhardt, M.

    1978-01-01

    The results of parallel determinations of digoxin in the sera of non selected patients (n=104) by enzyme immunoassay (EMIT.EIA) and radioimmunoassay (J-125 labeled RIA) were compared with each other. The determinations revealed considerably different concentrations; the values determined by EIA were statistical lower (for EIA 1,09+'0,99ng/ml, for RIA 1,34+'1,01ng/ml, p [de

  12. A study using an isotope probe comparing immunoassay with serology in detection of Brucella Abortus antibody

    International Nuclear Information System (INIS)

    Devlin, J.G.; Redington, F.; Stephenson, M.

    1986-01-01

    We report a comparison of radio-immunoassay with conventional serology in the detection of brucella abortus antibody from three laboratories. Overall agreement by Chi squared analysis is 5%. There are significant differences between laboratories and a significant number of sero negative suspect sera (from 20% - 60%) were positive by ratio-immunoassay test. We suspect that conventional serology under-reports the incidence of antibody to brucella abortus. (author)

  13. Designing novel nano-immunoassays: antibody orientation versus sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Puertas, S; Moros, M; Fernandez-Pacheco, R; Ibarra, M R; Grazu, V; De la Fuente, J M, E-mail: vgrazu@unizar.e, E-mail: jmfuente@unizar.e [Instituto de Nanociencia de Aragon (INA), Universidad de Zaragoza, Campus RIo Ebro, EdifIcio I-D, Mariano Esquillor, s/n, 50018 Zaragoza (Spain)

    2010-12-01

    There is a growing interest in the use of magnetic nanoparticles (MNPs) for their application in quantitative and highly sensitive biosensors. Their use as labels of biological recognition events and their detection by means of some magnetic method constitute a very promising strategy for quantitative high-sensitive lateral-flow assays. In this paper, we report the importance of nanoparticle functionalization for the improvement of sensitivity for a lateral-flow immunoassay. More precisely, we have found that immobilization of IgG anti-hCG through its polysaccharide moieties on MNPs allows more successful recognition of the hCG hormone. Although we have used the detection of hCG as a model in this work, the strategy of binding antibodies to MNPs through its sugar chains reported here is applicable to other antibodies. It has huge potential as it will be very useful for the development of quantitative and high-sensitive lateral-flow assays for its use on human and veterinary, medicine, food and beverage manufacturing, pharmaceutical, medical biologics and personal care product production, environmental remediation, etc.

  14. A Novel Colorimetric Immunoassay Utilizing the Peroxidase Mimicking Activity of Magnetic Nanoparticles

    Directory of Open Access Journals (Sweden)

    Hyun Gyu Park

    2013-05-01

    Full Text Available A simple colorimetric immunoassay system, based on the peroxidase mimicking activity of Fe3O4 magnetic nanoparticles (MNPs, has been developed to detect clinically important antigenic molecules. MNPs with ca. 10 nm in diameter were synthesized and conjugated with specific antibodies against target molecules, such as rotaviruses and breast cancer cells. Conjugation of the MNPs with antibodies (MNP-Abs enabled specific recognition of the corresponding target antigenic molecules through the generation of color signals arising from the colorimetric reaction between the selected peroxidase substrate, 3,3',5,5'-tetramethylbenzidine (TMB and H2O2. Based on the MNP-promoted colorimetric reaction, the target molecules were detected and quantified by measuring absorbance intensities corresponding to the oxidized form of TMB. Owing to the higher stabilities and economic feasibilities of MNPs as compared to horseradish peroxidase (HRP, the new colorimetric system employing MNP-Abs has the potential of serving as a potent immunoassay that should substitute for conventional HRP-based immunoassays. The strategy employed to develop the new methodology has the potential of being extended to the construction of simple diagnostic systems for a variety of biomolecules related to human cancers and infectious diseases, particularly in the realm of point-of-care applications.

  15. Fast and sensitive detection of enteropathogenic Yersinia by immunoassays.

    Science.gov (United States)

    Laporte, Jérôme; Savin, Cyril; Lamourette, Patricia; Devilliers, Karine; Volland, Hervé; Carniel, Elisabeth; Créminon, Christophe; Simon, Stéphanie

    2015-01-01

    Yersinia enterocolitica and Yersinia pseudotuberculosis, the two Yersinia species that are enteropathogenic for humans, are distributed worldwide and frequently cause diarrhea in inhabitants of temperate and cold countries. Y. enterocolitica is a major cause of foodborne disease resulting from consumption of contaminated pork meat and is further associated with substantial economic cost. However, investigation of enteropathogenic Yersinia species is infrequently performed routinely in clinical laboratories because of their specific growth characteristics, which make difficult their isolation from stool samples. Moreover, current isolation procedures are time-consuming and expensive, thus leading to underestimates of the incidence of enteric yersiniosis, inappropriate prescriptions of antibiotic treatments, and unnecessary appendectomies. The main objective of the study was to develop fast, sensitive, specific, and easy-to-use immunoassays, useful for both human and veterinary diagnosis. Monoclonal antibodies (MAbs) directed against Y. enterocolitica bioserotypes 2/O:9 and 4/O:3 and Y. pseudotuberculosis serotypes I and III were produced. Pairs of MAbs were selected by testing their specificity and affinity for enteropathogenic Yersinia and other commonly found enterobacteria. Pairs of MAbs were selected to develop highly sensitive enzyme immunoassays (EIAs) and lateral flow immunoassays (LFIs or dipsticks) convenient for the purpose of rapid diagnosis. The limit of detection of the EIAs ranged from 3.2 × 10(3) CFU/ml to 8.8 × 10(4) CFU/ml for pathogenic serotypes I and III of Y. pseudotuberculosis and pathogenic bioserotypes 2/O:9 and 4/O:3 of Y. enterocolitica and for the LFIs ranged from 10(5) CFU/ml to 10(6) CFU/ml. A similar limit of detection was observed for artificially contaminated human feces. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  16. Kinase Activity Studied in Living Cells Using an Immunoassay

    Science.gov (United States)

    Bavec, Aljos?a

    2014-01-01

    This laboratory exercise demonstrates the use of an immunoassay for studying kinase enzyme activity in living cells. The advantage over the classical method, in which students have to isolate the enzyme from cell material and measure its activity in vitro, is that enzyme activity is modulated and measured in living cells, providing a more…

  17. Comparison of infrared-excited up-converting phosphors and europium nanoparticles as labels in a two-site immunoassay

    International Nuclear Information System (INIS)

    Ukonaho, Telle; Rantanen, Terhi; Jaemsen, Laura; Kuningas, Katri; Paekkilae, Henna; Loevgren, Timo; Soukka, Tero

    2007-01-01

    Research in the field of immunoassays and labels used in the detection has been recently focused on particulate reporters, which possess very high specific activity that excludes the label as a sensitivity limiting factor. However, the large size and shape of the particulate labels may produce additional problems to immunoassay performance. The aim of this work was to study with two identical non-competitive two-site immunoassays whether up-converting phosphor (UCP) particles are comparable in performance with europium(III) chelate-dyed nanoparticles as particulate labels. In addition we strived to verify the common assumption of the photostability of up-converting phosphor particles supporting their potential applicability in imaging. Detection limits in two-site immunoassay for free prostate-specific antigen (free-PSA) were 0.53 ng L -1 and 1.3 ng L -1 using two different up-converting phosphors and 0.16 ng L -1 using europium(III) nanoparticle. Large size distribution and non-specific binding of up-converting phosphor particles caused assay variation in low analyte concentrations and limited the analytical detection limit. The non-specific binding was the major factor limiting the analytical sensitivity of the immunoassay. The results suggests the need for nanoscaled and uniformely sized UCP-particles to increace the sensitivity and applicability of up-converting phosphor particles. Anti-Stokes photoluminescence of up-converting phosphor particles did not photobleach when measured repeatedly, on the contrary, the time-resolved fluorescence of europium nanoparticles photobleached relatively rapidly

  18. Immunoassay for Capsular Antigen of Bacillus anthracis Enables Rapid Diagnosis in a Rabbit Model of Inhalational Anthrax.

    Directory of Open Access Journals (Sweden)

    Marcellene A Gates-Hollingsworth

    Full Text Available Inhalational anthrax is a serious biothreat. Effective antibiotic treatment of inhalational anthrax requires early diagnosis; the further the disease has progressed, the less the likelihood for cure. Current means for diagnosis such as blood culture require several days to a result and require advanced laboratory infrastructure. An alternative approach to diagnosis is detection of a Bacillus anthracis antigen that is shed into blood and can be detected by rapid immunoassay. The goal of the study was to evaluate detection of poly-γ-D-glutamic acid (PGA, the capsular antigen of B. anthracis, as a biomarker surrogate for blood culture in a rabbit model of inhalational anthrax. The mean time to a positive blood culture was 26 ± 5.7 h (mean ± standard deviation, whereas the mean time to a positive ELISA was 22 ± 4.2 h; P = 0.005 in comparison with blood culture. A lateral flow immunoassay was constructed for detection of PGA in plasma at concentrations of less than 1 ng PGA/ml. Use of the lateral flow immunoassay for detection of PGA in the rabbit model found that antigen was detected somewhat earlier than the earliest time point at which the blood culture became positive. The low cost, ease of use, and rapid time to result of the lateral flow immunoassay format make an immunoassay for PGA a viable surrogate for blood culture for detection of infection in individuals who have a likelihood of exposure to B. anthracis.

  19. A summary report on the 23rd quality control survey for immunoassays in Japan, 2001

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-10-01

    The purpose of the survey is to improve the quality of in vitro tests and this report is its summary of immunoassays (the old name: RI in vitro tests) conducted in 2001. The survey was performed in 143 facilities out of 1,655 in Japan, which involved 20 national and public university hospitals, 16 private university hospitals, 21 national and public hospitals, 26 private hospitals, 41 hygiene test institutes and 19 reagent manufacturers. Tests examined were on 6 substances related to functions of pituitary, 5 of thyroid, 1 of parathyroid, 4 of gastro-intestine and pancreas, 5 of gonad and placenta, 4 of adrenal, 1 of renal-blood pressure regulation, on IgE, on digoxin and on 12 tumor-related substances. Tests were done on 2-3 samples supplied from the Committee and the mean, standard deviation and coefficient of variation were calculated for one way analysis of variance of within- and between-kit. Methods included those (65.4% vs 62.7% in 2000) with non-radioisotope like enzyme immunoassay (non-RI) and with radioisotopes like radioimmunoassay (RI). Dissociation between manufacturers of non-RI values without a common standard substance and between non-RI and RI values even with the same antibody was noted: the Committee considered these problems as their future task. (K.H.)

  20. A hybrid EKF and switching PSO algorithm for joint state and parameter estimation of lateral flow immunoassay models.

    Science.gov (United States)

    Zeng, Nianyin; Wang, Zidong; Li, Yurong; Du, Min; Liu, Xiaohui

    2012-01-01

    In this paper, a hybrid extended Kalman filter (EKF) and switching particle swarm optimization (SPSO) algorithm is proposed for jointly estimating both the parameters and states of the lateral flow immunoassay model through available short time-series measurement. Our proposed method generalizes the well-known EKF algorithm by imposing physical constraints on the system states. Note that the state constraints are encountered very often in practice that give rise to considerable difficulties in system analysis and design. The main purpose of this paper is to handle the dynamic modeling problem with state constraints by combining the extended Kalman filtering and constrained optimization algorithms via the maximization probability method. More specifically, a recently developed SPSO algorithm is used to cope with the constrained optimization problem by converting it into an unconstrained optimization one through adding a penalty term to the objective function. The proposed algorithm is then employed to simultaneously identify the parameters and states of a lateral flow immunoassay model. It is shown that the proposed algorithm gives much improved performance over the traditional EKF method.

  1. False biochemical diagnosis of hyperthyroidism in streptavidin-biotin-based immunoassays: the problem of biotin intake and related interferences.

    Science.gov (United States)

    Piketty, Marie-Liesse; Polak, Michel; Flechtner, Isabelle; Gonzales-Briceño, Laura; Souberbielle, Jean-Claude

    2017-05-01

    Immunoassays are now commonly used for hormone measurement, in high throughput analytical platforms. Immunoassays are generally robust to interference. However, endogenous analytical error may occur in some patients; this may be encountered in biotin supplementation or in the presence of anti-streptavidin antibody, in immunoassays involving streptavidin-biotin interaction. In these cases, the interference may induce both false positive and false negative results, and simulate a seemingly coherent hormonal profile. It is to be feared that this type of errors will be more frequently observed. This review underlines the importance of keeping close interactions between biologists and clinicians to be able to correlate the hormonal assay results with the clinical picture.

  2. Targeted selected reaction monitoring mass spectrometric immunoassay for insulin-like growth factor 1.

    Directory of Open Access Journals (Sweden)

    Eric E Niederkofler

    Full Text Available Insulin-like growth factor 1 (IGF1 is an important biomarker of human growth disorders that is routinely analyzed in clinical laboratories. Mass spectrometry-based workflows offer a viable alternative to standard IGF1 immunoassays, which utilize various pre-analytical preparation strategies. In this work we developed an assay that incorporates a novel sample preparation method for dissociating IGF1 from its binding proteins. The workflow also includes an immunoaffinity step using antibody-derivatized pipette tips, followed by elution, trypsin digestion, and LC-MS/MS separation and detection of the signature peptides in a selected reaction monitoring (SRM mode. The resulting quantitative mass spectrometric immunoassay (MSIA exhibited good linearity in the range of 1 to 1,500 ng/mL IGF1, intra- and inter-assay precision with CVs of less than 10%, and lowest limits of detection of 1 ng/mL. The linearity and recovery characteristics of the assay were also established, and the new method compared to a commercially available immunoassay using a large cohort of human serum samples. The IGF1 SRM MSIA is well suited for use in clinical laboratories.

  3. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Science.gov (United States)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L- 1 and 0.054 μg L- 1 with the relative standard deviations (RSDs, n = 7, c = 5 μg L- 1) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2-50 μg L- 1. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications.

  4. Simplified immunoassay for rapid Dengue serotype diagnosis, revealing insensitivity to non-specific binding interference

    Directory of Open Access Journals (Sweden)

    Fernanda C.C.L. Loureiro

    2017-04-01

    Full Text Available Proof of concept of an immunoassay, which is easy to implement, for rapid Dengue virus (DENV serotype diagnosis, in the early infection stage, is reported. The four-layer assay is immobilized onto a thin gold film and relies on a low cost, disposable polymer biochip for optical surface plasmon resonance sensing and detection. The protocol comprises Neutravidin-Biotin mediated monoclonal antibody (MAB attachment as the functionalized sensing element. Formation of the MAB-DENV complex results in a pronounced thickness change that is optically recorded in real time, employing a microfluidic set-up. Virus presence is confirmed by atomic force microscopy from the same sample. Serum samples were collected from a patient in acute febrile state. Simultaneous serological analysis by means of the reverse transcription polymerase chain reaction, independently, confirmed presence of DENV2 and DENV3. The protocol proved applicable in presence of strong non-specific binding interference that originates from, and is caused by, various blood, serum and other body fluid constituents. False positive indications for both, negative serum and blood control samples were not observed. The achievable limit of detection was estimated to be 2×104 particles/ml. Eventually, the method can be modified towards detection of other viruses by using the same protocol. Keywords: Immuno-assay, Dengue virus detection, Non-specific binding

  5. 340 nm pulsed UV LED system for europium-based time-resolved fluorescence detection of immunoassays

    OpenAIRE

    Rodenko, Olga; Fodgaard, Henrik; Tidemand-Lichtenberg, Peter; Petersen, Paul Michael; Pedersen, Christian

    2016-01-01

    We report on the design, development and investigation of an optical system based on UV light emitting diode (LED) excitation at 340 nm for time-resolved fluorescence detection of immunoassays. The system was tested to measure cardiac marker Troponin I with a concentration of 200 ng/L in immunoassay. The signal-to-noise ratio was comparable to state-of-the-art Xenon flash lamp based unit with equal excitation energy and without overdriving the LED. We performed a comparative study of the flas...

  6. Nanobody-based electrochemical immunoassay for Bacillus thuringiensis Cry1Ab toxin by detecting the enzymatic formation of polyaniline

    International Nuclear Information System (INIS)

    Zhu, Min; Li, Guanghui; Li, Min; Zhou, Zikai; Liu, Hong; Lei, Hongtao; Shen, Yanfei; Wan, Yakun

    2015-01-01

    We describe an electrochemical immunoassay for the Cry1Ab toxin that is produced by Bacillus thuringiensis. It is making use of a nanobody (a heavy-chain only antibody) that was selected from an immune phage displayed library. A biotinylated primary nanobody and a HRP-conjugated secondary nanobody were applied in a sandwich immunoassay where horseradish peroxidase (HRP) is used to produce polyaniline (PANI) from aniline. PANI can be easily detected by differential pulse voltammetry at a working voltage as low as 40 mV (vs. Ag/AgCl) which makes the assay fairly selective. This immunoassay for Cry1Ab has an analytical range from 0.1 to 1000 ng∙mL -1 and a 0.07 ng∙mL -1 lower limit of detection. The average recoveries of the toxin from spiked samples are in the range from 102 to 114 %, with a relative standard deviation of <7.5 %. The results demonstrated that the assay represented an attractive alternative to existing immunoassays in enabling affordable, sensitive, robust and specific determination of this toxin. (author)

  7. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  8. MIT Lincoln Laboratory: Technology in Support of National Security

    Science.gov (United States)

    2011-01-01

    technologies that could be uti - lized in future Landsat satellites to achieve significant economies of mass, size, power consumption, and cost, and...epitomized by the pregnancy test kit. However, immunoassays are typically based on anti bodies removed from their host cells and placed on substrates

  9. Correlations between calcineurin phosphatase inhibition and cyclosporine metabolites concentrations in kidney transplant recipients: Implications for immunoassays

    DEFF Research Database (Denmark)

    Jørgensen, Kaj Anker; Karamperis, Nikolaos; Koefoed-Nielsen, Pernille Bundgaard

    2006-01-01

    by inhibiting the enzyme calcineurin phosphatase. Determination of the enzyme's activity is one of the most promising pharmacodynamic markers. It is unknown how calcineurin phosphatase inhibition correlates with various cyclosporine monitoring assays and what is the potential impact of metabolites...... by the enzyme multiplied immunoassay technique (EMIT) and by the polyclonal fluorescence polarization immunoassay (pFPIA). Calcineurin phosphatase activity was measured by its ability to dephosphorylate a previously phosphorylated 19-amino acid peptide. We found that calcineurin phosphatase inhibition...

  10. Correlations between calcineurin phosphatase inhibition and cyclosporine metabolites concentrations in kidney transplant recipients: implications for immunoassays

    DEFF Research Database (Denmark)

    Karamperis, N; Koefoed-Nielsen, PB; Brahe, P

    2006-01-01

    by inhibiting the enzyme calcineurin phosphatase. Determination of the enzyme's activity is one of the most promising pharmacodynamic markers. It is unknown how calcineurin phosphatase inhibition correlates with various cyclosporine monitoring assays and what is the potential impact of metabolites...... by the enzyme multiplied immunoassay technique (EMIT) and by the polyclonal fluorescence polarization immunoassay (pFPIA). Calcineurin phosphatase activity was measured by its ability to dephosphorylate a previously phosphorylated 19-amino acid peptide. We found that calcineurin phosphatase inhibition...

  11. Multiplex dipstick immunoassay for semi-quantitative determination of Fusarium mycotoxins in cereals

    Energy Technology Data Exchange (ETDEWEB)

    Lattanzio, Veronica M.T., E-mail: veronica.lattanzio@ispa.cnr.it [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy); Nivarlet, Noan [UNISENSOR S.A., Zoning industriel du Dossay, Rue du Dossay no 3, B-4020 Liege (Belgium); Lippolis, Vincenzo; Gatta, Stefania Della [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy); Huet, Anne-Catherine; Delahaut, Philippe [Centre d' Economie Rurale (CER Groupe), Rue du Point du Jour no 8, B-6900 Marloie (Belgium); Granier, Benoit [UNISENSOR S.A., Zoning industriel du Dossay, Rue du Dossay no 3, B-4020 Liege (Belgium); Visconti, Angelo [National Research Council of Italy, Institute of Sciences of Food Production (ISPA-CNR), Via Amendola 122/O, 70126 Bari (Italy)

    2012-03-09

    Highlights: Black-Right-Pointing-Pointer We developed a rapid method based on a multiplex dipstick immunoassay. Black-Right-Pointing-Pointer The assay allowed the determination of major Fusarium toxins in wheat, oats, maize. Black-Right-Pointing-Pointer We obtained cut off levels close to EU regulatory levels. - Abstract: A multiplex dipstick immunoassay based method for the simultaneous determination of major Fusarium toxins, namely zearalenone, T-2 and HT-2 toxins, deoxynivalenol and fumonisins in wheat, oats and maize has been developed. The dipstick format was based on an indirect competitive approach. Four test lines (mycotoxin-BSA conjugates) and one control line were located on the strip membrane. Labelled antibodies were freeze-dried within the microwell. Two matrix-related sample preparation protocols have been developed for wheat/oats (not containing fumonisins) and maize (containing fumonisins) respectively. The use of a methanol/water mixture for sample preparation allowed recoveries in the range 73-109% for all mycotoxins in all tested cereals, with relative standard deviation less than 10%. The optimized immunoassay was able to detect target mycotoxins at cut off levels equal to 80% of EU maximum permitted levels, i.e. 280, 400, 1400 and 3200 {mu}g kg{sup -1}, respectively, for zearalenone, T-2/HT-2 toxins, deoxynivalenol and fumonisins in maize, and 80, 400 and 1400 {mu}g kg{sup -1}, respectively, for zearalenone, T-2/HT-2 toxins and deoxynivalenol in wheat and oats. Analysis of naturally contaminated samples resulted in a good agreement between multiplex dipstick and validated confirmatory LC-MS/MS. The percentage of false positive results was less than or equal to 13%, whereas no false negative results were obtained. Data on the presence/absence of 6 mycotoxins at levels close to EU regulatory levels were obtained within 30 min. The proposed immunoassay protocol is rapid, inexpensive, easy-to-use and fit for purpose of rapid screening of mycotoxins

  12. Aequorin fusion proteins as bioluminescent tracers for competitive immunoassays

    Science.gov (United States)

    Mirasoli, Mara; Michelini, Elisa; Deo, Sapna K.; Dikici, Emre; Roda, Aldo; Daunert, Sylvia

    2004-06-01

    The use of bio- and chemiluminescence for the development of quantitative binding assays offers undoubted advantages over other detection systems, such as spectrophotometry, fluorescence, or radioactivity. Indeed, bio- and chemiluminescence detection provides similar, or even better, sensitivity and detectability than radioisotopes, while avoiding the problems of health hazards, waste disposal, and instability associated with the use of radioisotopes. Among bioluminescent labels, the calcium-activated photoprotein aequorin, originally isolated from Aequorea victoria and today available as a recombinant product, is characterized by very high detectability, down to attomole levels. It has been used as a bioluminescent label for developing a variety of highly sensitive immunoassays, using various analyte-aequorin conjugation strategies. When the analyte is a protein or a peptide, genetic engineering techniques can be used to produce protein fusions where the analyte is in-frame fused with aequorin, thus producing homogeneous one-to-one conjugation products, available in virtually unlimited amount. Various assays were developed using this strategy: a short review of the most interesting applications is presented, as well as the cloning, purification and initial characterization of an endothelin-1-aequorin conjugate suitable for developing a competitive immunoassay for endothelin-1, a potent vasoconstrictor peptide, involved in hypertension.

  13. Trace-level mercury ion (Hg2+) analysis in aqueous sample based on solid-phase extraction followed by microfluidic immunoassay.

    Science.gov (United States)

    Date, Yasumoto; Aota, Arata; Terakado, Shingo; Sasaki, Kazuhiro; Matsumoto, Norio; Watanabe, Yoshitomo; Matsue, Tomokazu; Ohmura, Naoya

    2013-01-02

    Mercury is considered the most important heavy-metal pollutant, because of the likelihood of bioaccumulation and toxicity. Monitoring widespread ionic mercury (Hg(2+)) contamination requires high-throughput and cost-effective methods to screen large numbers of environmental samples. In this study, we developed a simple and sensitive analysis for Hg(2+) in environmental aqueous samples by combining a microfluidic immunoassay and solid-phase extraction (SPE). Using a microfluidic platform, an ultrasensitive Hg(2+) immunoassay, which yields results within only 10 min and with a lower detection limit (LOD) of 0.13 μg/L, was developed. To allow application of the developed immunoassay to actual environmental aqueous samples, we developed an ion-exchange resin (IER)-based SPE for selective Hg(2+) extraction from an ion mixture. When using optimized SPE conditions, followed by the microfluidic immunoassay, the LOD of the assay was 0.83 μg/L, which satisfied the guideline values for drinking water suggested by the United States Environmental Protection Agency (USEPA) (2 μg/L; total mercury), and the World Health Organisation (WHO) (6 μg/L; inorganic mercury). Actual water samples, including tap water, mineral water, and river water, which had been spiked with trace levels of Hg(2+), were well-analyzed by SPE, followed by microfluidic Hg(2+) immunoassay, and the results agreed with those obtained from reduction vaporizing-atomic adsorption spectroscopy.

  14. Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays

    Directory of Open Access Journals (Sweden)

    John Miller

    2015-04-01

    Full Text Available We report use of U-shaped biconically tapered optical fibers (BTOF as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G-antigen (rabbit anti-mouse IgG reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method.

  15. An enzyme immunoassay to quantify neurofilament light chain in cerebrospinal fluid.

    NARCIS (Netherlands)

    Geel, W.J.A. van; Rosengren, L.E.; Verbeek, M.M.

    2005-01-01

    Neurofilament light chain is a component of the axonal cytoskeleton. The concentration of the neurofilament light chain in cerebrospinal fluid may reflect axonal damage or the extent of white matter damage. In this study we describe a sensitive immunoassay for the detection of neurofilament light

  16. IMMUNOASSAY METHOD FOR THE DETERMINATION OF PENTACHLOROPHENOL IN SOIL AND SEDIMENT

    Science.gov (United States)

    The journal article describes the use of a prototype immunoassay method for the determination of pentacholorphenol (PCP) in soil and sediment. PCP was used as a pesticide and wood preservative and is not currently available to the general public. The paper stresses the importan...

  17. Development of monoclonal antibody-based immunoassays for the analysis of bisphenol A in canned vegetables.

    Science.gov (United States)

    Moreno, María J; D'Arienzo, Pasquale; Manclús, Juan J; Montoya, Angel

    2011-01-01

    The aim of this work was the development of monoclonal antibodies (MAbs) and highly sensitive immunoassays (ELISAs) to bisphenol A (BPA), a well-known endocrine disruptor able to migrate from the internal coating of cans to food contained inside, particularly vegetables. To produce MAbs to BPA, four synthetic compounds were conjugated to proteins and used as immunizing haptens in mice. By applying hybridoma technology, several MAbs were produced and selected. These antibodies were characterized in the conjugate-coated and in the antibody-coated formats, using both homologous and heterologous conjugates. Three indirect ELISA based on the MAbs showing the highest affinity to BPA were selected. The limit of detection of the most sensitive ELISA was 0.22 nM (0.05 ng/mL), with an I₅₀ value of around 1 nM (0.23 ng/mL). An homologous ELISA based on the MAb BPAB-11 was applied to the simple, direct determination of BPA in the liquid portion of canned artichoke, peas, and sweet corn. Only sample dilution in an appropriate saline buffer was required to minimize matrix effects and to enter the ELISA working range. Recovery and precision of the method were evaluated by spiking the liquid portion of these cans with BPA at 20, 50, and 100 ng/mL. Coefficients of variation were below 20% in most cases. With regard to recovery, the analytical data obtained were also acceptable. This immunoassay has therefore proved its potential as a new tool for the rapid, sensitive and accurate determination of BPA in canned food.

  18. Immunoassay for thymopoietin

    International Nuclear Information System (INIS)

    Goldstein, G.

    1979-01-01

    The patent describes the development of a radio-immunoassay for thymopoietin in biological samples. The method of raising antibodies to this polypeptide hormone is described. This is achieved by injecting a host animal with an antigen consisting of thymopoietin covalently bonded by glutaraldehyde to a carrier protein such as bovine serum albumin and equine globulin. Different methods of radiolabelling thymopoietin with 125 I for use as the tracer antigen are described. The Bolton-Hunter procedure was preferred to the chloramine-T method since direct iodination of the tyrosyl moieties of thymopoietin resulted in some loss of immunoreactivity. Systems for separating the antigen-antibody complex and unbound antigen are compared. Binding-inhibition curves for unlabelled thymopoietin in the assay employing polyethylene glycol separation showed a sensitivity of 5 ng thymopoietin/ml. However, using the double antibody or dextran coated charcoal separation techniques, the sensitivity of thymopoietin was 0.1 ng/ml. Thus these latter two procedures are thus especially suitable for measuring thymopoietin levels in serum or plasma samples. The assay was shown to be specific for thymopoietin, no significant displacement being produced by control polypeptides. (U.K.)

  19. Serum sample containing endogenous antibodies interfering with multiple hormone immunoassays. Laboratory strategies to detect interference

    Directory of Open Access Journals (Sweden)

    Elena García-González

    2016-04-01

    Full Text Available Objectives: Endogenous antibodies (EA may interfere with immunoassays, causing erroneous results for hormone analyses. As (in most cases this interference arises from the assay format and most immunoassays, even from different manufacturers, are constructed in a similar way, it is possible for a single type of EA to interfere with different immunoassays. Here we describe the case of a patient whose serum sample contains EA that interfere several hormones tests. We also discuss the strategies deployed to detect interference. Subjects and methods: Over a period of four years, a 30-year-old man was subjected to a plethora of laboratory and imaging diagnostic procedures as a consequence of elevated hormone results, mainly of pituitary origin, which did not correlate with the overall clinical picture. Results: Once analytical interference was suspected, the best laboratory approaches to investigate it were sample reanalysis on an alternative platform and sample incubation with antibody blocking tubes. Construction of an in-house ‘nonsense’ sandwich assay was also a valuable strategy to confirm interference. In contrast, serial sample dilutions were of no value in our case, while polyethylene glycol (PEG precipitation gave inconclusive results, probably due to the use of inappropriate PEG concentrations for several of the tests assayed. Conclusions: Clinicians and laboratorians must be aware of the drawbacks of immunometric assays, and alert to the possibility of EA interference when results do not fit the clinical pattern. Keywords: Endogenous antibodies, Immunoassay, Interference, Pituitary hormones, Case report

  20. On-Chip Immunoassay for Determination of Urinary Albumin

    OpenAIRE

    Laiwattanapaisal, Wanida; Songjaroen, Temsiri; Maturos, Thitima; Lomas, Tanom; Sappat, Assawapong; Tuantranont, Adisorn

    2009-01-01

    An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane) (PDMS) microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993), with a detection limit of 0.81 mg L–1 (S/N = 3). The proposed system showed good precision, with relative standard deviations (...

  1. Immunoassay: Principles, development and potential applications in the applied plant sciences

    Energy Technology Data Exchange (ETDEWEB)

    Hofman, P J

    1986-02-01

    The article briefly discusses the general principles of, and the methods involved in, immunoassay, and their development. Emplasis is placed on radioimmunoassay (RIA) and to a lesser extent, enzyme-linked immunosorbent assay (ELISA). The practical applications, with special reference to the citrus and subtropical fruit industries are discussed.

  2. Development of a prototype lateral flow immunoassay (LFI for the rapid diagnosis of melioidosis.

    Directory of Open Access Journals (Sweden)

    Raymond L Houghton

    2014-03-01

    Full Text Available Burkholderia pseudomallei is a soil-dwelling bacterium and the causative agent of melioidosis. Isolation of B. pseudomallei from clinical samples is the "gold standard" for the diagnosis of melioidosis; results can take 3-7 days to produce. Alternatively, antibody-based tests have low specificity due to a high percentage of seropositive individuals in endemic areas. There is a clear need to develop a rapid point-of-care antigen detection assay for the diagnosis of melioidosis. Previously, we employed In vivo Microbial Antigen Discovery (InMAD to identify potential B. pseudomallei diagnostic biomarkers. The B. pseudomallei capsular polysaccharide (CPS and numerous protein antigens were identified as potential candidates. Here, we describe the development of a diagnostic immunoassay based on the detection of CPS. Following production of a CPS-specific monoclonal antibody (mAb, an antigen-capture immunoassay was developed to determine the concentration of CPS within a panel of melioidosis patient serum and urine samples. The same mAb was used to produce a prototype Active Melioidosis Detect Lateral Flow Immunoassay (AMD LFI; the limit of detection of the LFI for CPS is comparable to the antigen-capture immunoassay (∼0.2 ng/ml. The analytical reactivity (inclusivity of the AMD LFI was 98.7% (76/77 when tested against a large panel of B. pseudomallei isolates. Analytical specificity (cross-reactivity testing determined that 97.2% of B. pseudomallei near neighbor species (35/36 were not reactive. The non-reactive B. pseudomallei strain and the reactive near neighbor strain can be explained through genetic sequence analysis. Importantly, we show the AMD LFI is capable of detecting CPS in a variety of patient samples. The LFI is currently being evaluated in Thailand and Australia; the focus is to optimize and validate testing procedures on melioidosis patient samples prior to initiation of a large, multisite pre-clinical evaluation.

  3. Non-radiometric immunoassays fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) and radioimmunoassay (RIA) for evaluation of thyroid function in normal and hypothyroid dogs

    Energy Technology Data Exchange (ETDEWEB)

    Jerico, M.M.; Larsson, C.E. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Dept. de Clinica Medica]. E-mail: marciajerico@hotmail.com; Mendonca, B.B. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina . Lab. de Hormonios e Genetica Molecular; Otsuka, M. [Sao Paulo Univ., SP (Brazil). Faculdade de Medicina Veterinaria e Zootecnia. Hospital Veterinario; Maganin Junior, A. [Canil da Policia Militar do Estado de Sao Paulo, SP (Brazil)

    2001-07-01

    We proposed the comparison of thyroxine (T4) and free thyroxine (FT4) measurements by fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) with radioimmunoassay (RIA) in thyroid function evaluation of normal (n=50) and hypothyroid dogs (n=9). T4 and FT4 serum concentrations were measured in basal conditions and 6 h after TRH stimulation (200 mug/IV). All our reference values are based on the 5th and 95th percentile. The reference values for basal T4 in healthy dogs were 0.50 to 2.35 mug/dL (FIA), 0.50 to 2.51 mug/dL (FEIA) and 0.35 to 0.74 mug/dL (RIA). After TRH, the values were >= 1.37 mug/dL (FIA), >= 0,26 mug/dL (FEIA) and >= 0.40 mug/dL (RIA). Basal FT4 values in healthy dogs were 0.65 to 2.20 ng/dL (FIA), 0.38 to 1.43 ng/dL (FEIA) and 0.10 to 1.24 ng/dL (RIA). After TRH, the values were >= 1.30 ng/dL (FIA), >= 0.77 ng/dL (FEIA) and >=0.50 ng/dL (RIA). In hypothyroid dogs, the mean +- SD for T4 in basal conditions and after TRH were 0.24 +- 0.20 mug/dL and 0.26 +- 0.20 mug/dL (FIA), 0.27 +- 0.12 mug/dL and 0.32 +- 0.51 mug/dL (FEIA) and 0.19 +- 0.30 mug/dL and 0,24 +- 0.09 mug/dL (RIA), respectively. In the same group the mean +- SD basal FT4 values and after TRH were 0.28 +- 0.33 ng/dL and 0.28 +- 0.39 ng/dL (FIA), 0,12 +- 0.26 ng/dL and 0.23 +- 0.56 ng/dL (FEIA) and 0,15 +- 0,15 ng/dL and 0,17 +- 0,28 ng/dL (RIA), respectively. Significant differences (p<0.05) between the normal and hypothyroid groups (Kruskall-Wallis test) were observed in the three methods and between basal and stimulated values in normal dogs (Wilcoxon test), by the three methods. The best sensitivity for diagnosing hypothyroidism was obtained through T4 values (100%), and the best specificity through FT4 values (100%), both determined by FIA after TRH stimulation. We conclude that T4 and FT4 measured by fluoroimmunoassay after TRH stimulation can be an excellent alternative. (author)

  4. Non-radiometric immunoassays (fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) and radioimmunoassay (RIA) for evaluation of thyroid function in normal and hypothyroid dogs

    International Nuclear Information System (INIS)

    Jerico, M.M.; Larsson, C.E.

    2001-01-01

    We proposed the comparison of thyroxine (T4) and free thyroxine (FT4) measurements by fluoroimmunoassay (FIA) and fluorometric enzyme immunoassay (FEIA) with radioimmunoassay (RIA) in thyroid function evaluation of normal (n=50) and hypothyroid dogs (n=9). T4 and FT4 serum concentrations were measured in basal conditions and 6 h after TRH stimulation (200 mug/IV). All our reference values are based on the 5th and 95th percentile. The reference values for basal T4 in healthy dogs were 0.50 to 2.35 mug/dL (FIA), 0.50 to 2.51 mug/dL (FEIA) and 0.35 to 0.74 mug/dL (RIA). After TRH, the values were >= 1.37 mug/dL (FIA), >= 0,26 mug/dL (FEIA) and >= 0.40 mug/dL (RIA). Basal FT4 values in healthy dogs were 0.65 to 2.20 ng/dL (FIA), 0.38 to 1.43 ng/dL (FEIA) and 0.10 to 1.24 ng/dL (RIA). After TRH, the values were >= 1.30 ng/dL (FIA), >= 0.77 ng/dL (FEIA) and >=0.50 ng/dL (RIA). In hypothyroid dogs, the mean +- SD for T4 in basal conditions and after TRH were 0.24 +- 0.20 mug/dL and 0.26 +- 0.20 mug/dL (FIA), 0.27 +- 0.12 mug/dL and 0.32 +- 0.51 mug/dL (FEIA) and 0.19 +- 0.30 mug/dL and 0,24 +- 0.09 mug/dL (RIA), respectively. In the same group the mean +- SD basal FT4 values and after TRH were 0.28 +- 0.33 ng/dL and 0.28 +- 0.39 ng/dL (FIA), 0,12 +- 0.26 ng/dL and 0.23 +- 0.56 ng/dL (FEIA) and 0,15 +- 0,15 ng/dL and 0,17 +- 0,28 ng/dL (RIA), respectively. Significant differences (p<0.05) between the normal and hypothyroid groups (Kruskall-Wallis test) were observed in the three methods and between basal and stimulated values in normal dogs (Wilcoxon test), by the three methods. The best sensitivity for diagnosing hypothyroidism was obtained through T4 values (100%), and the best specificity through FT4 values (100%), both determined by FIA after TRH stimulation. We conclude that T4 and FT4 measured by fluoroimmunoassay after TRH stimulation can be an excellent alternative. (author)

  5. On-chip signal amplification of magnetic bead-based immunoassay by aviating magnetic bead chains.

    Science.gov (United States)

    Jalal, Uddin M; Jin, Gyeong Jun; Eom, Kyu Shik; Kim, Min Ho; Shim, Joon S

    2017-11-06

    In this work, a Lab-on-a-Chip (LOC) platform is used to electromagnetically actuate magnetic bead chains for an enhanced immunoassay. Custom-made electromagnets generate a magnetic field to form, rotate, lift and lower the magnetic bead chains (MBCs). The cost-effective, disposable LOC platform was made with a polymer substrate and an on-chip electrochemical sensor patterned via the screen-printing process. The movement of the MBCs is controlled to improve the electrochemical signal up to 230% when detecting beta-type human chorionic gonadotropin (β-hCG). Thus, the proposed on-chip MBC-based immunoassay is applicable for rapid, qualitative electrochemical point-of-care (POC) analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Diagnostic effectiveness of immunoassays systems for hepatitis C virus in samples from multi-transfusion patients

    International Nuclear Information System (INIS)

    Rivero Jimenez, Rene A; Merlin Linares, Julio C; Blanco de Armas, Madelin; Navea Leyva, Leonor M

    2009-01-01

    Hepatitis C virus (CHV) blood-transmission is a health problem in Cuba and in the world. Some types of diagnostic immunoassays have been developed for the blood certification and in general have a high diagnostic sensitivity and specificity in healthy donors. However, its behavior in samples from multi-transfusion patients could by less effective. To assess the diagnostic effectiveness of the UMELISA HCV third generation Cuban immunoassay (TecnoSUMA, S.A. La Habana), Cuba) in samples from multi-transfusion patients, in parallel, 335 sera from patients were processed by UBI HCV EIA 4.0 (United Biomedical, EE.UU) and UMELISA HCV third generation, and the samples with incongruous results were verified by PCR COBAS AmpliScreen HCV Test, v2 system (Roche, EE.UU.) Comparing the UMELISA HCV third generation system with the UBI HCV EIA 4.0 it was achieved a Sd of 95,8% CI(95%): 92,5-99,15 and a Ed of 100% CI (95%): 99,7-100, with IY: 0,96 (0,93-0,99) with k: 0,0582 ID (95%): 0,9276-0,9888, p = 0,000. Both immunoassay systems were satisfactory for immunodiagnosis of multi-transfusion patients

  7. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer

    Directory of Open Access Journals (Sweden)

    Xiaoling Fu

    2018-03-01

    Full Text Available The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA was presented for the clinical determination and analysis of human epididymis protein 4 (HE4 in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0–1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA, with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum. Keywords: Chemiluminescence immunoassay, Magnetic particles, Human epididymis protein 4

  8. Multiplex competitive microbead-based flow cytometric immunoassay using quantum dot fluorescent labels

    International Nuclear Information System (INIS)

    Yu, Hye-Weon; Kim, In S.; Niessner, Reinhard; Knopp, Dietmar

    2012-01-01

    Highlights: ► First time, duplex competitive bead-based flow cytometric immunoassay was developed using ODs. ► Antibody-coated QD detection probes and antigen-immobilized microspheres were synthesized. ► The two model target analytes were low molecular weight compounds of microbial and chemical origin. ► The determination of different water types was possible after simple filtration of samples. - Abstract: In answer to the ever-increasing need to perform the simultaneous analysis of environmental hazards, microcarrier-based multiplex technologies show great promise. Further integration with biofunctionalized quantum dots (QDs) creates new opportunities to extend the capabilities of multicolor flow cytometry with their unique fluorescence properties. Here, we have developed a competitive microbead-based flow cytometric immunoassay using QDs fluorescent labels for simultaneous detection of two analytes, bringing the benefits of sensitive, rapid and easy-of-manipulation analytical tool for environmental contaminants. As model target compounds, the cyanobacterial toxin microcystin-LR and the polycyclic aromatic hydrocarbon compound benzo[a]pyrene were selected. The assay was carried out in two steps: the competitive immunological reaction of multiple targets using their exclusive sensing elements of QD/antibody detection probes and antigen-coated microsphere, and the subsequent flow cytometric analysis. The fluorescence of the QD-encoded microsphere was thus found to be inversely proportional to target analyte concentration. Under optimized conditions, the proposed assay performed well within 30 min for the identification and quantitative analysis of the two environmental contaminants. For microcystin-LR and benzo[a]pyrene, dose–response curves with IC 50 values of 5 μg L −1 and 1.1 μg L −1 and dynamic ranges of 0.52–30 μg L −1 and 0.13–10 μg L −1 were obtained, respectively. Recovery was 92.6–106.5% for 5 types of water samples like bottled

  9. A New Method of Creating Technology/Function Matrix for Systematic Innovation without Expert

    Directory of Open Access Journals (Sweden)

    Tien-Yuan Cheng

    2012-02-01

    Full Text Available The technology/function matrix is comprised by specific technologies and functions, and through the technology/function matrix we can known what the technologies with functions have opportunities for innovation of product or technology. However, the technology/function matrix is very difficult to create, because the patents need to be read, analyzed and categorized into the technology/function matrix always more than hundreds or thousands. In this research, I propose a method to create a technology/function matrix just need to execute patent search without reading and analyzing patents. Through the proposed method anyone can create a technology/function matrix in a short time without experts’ help even if there are thousands of thousands of patents need to be read and analyzed.

  10. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    International Nuclear Information System (INIS)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong; Shi, Hanchang; Long, Feng

    2016-01-01

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  11. Universal quantum dot-based sandwich-like immunoassay strategy for rapid and ultrasensitive detection of small molecules using portable and reusable optofluidic nano-biosensing platform

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Liping; Zhu, Anna; Lou, Xuening; Song, Dan; Yang, Rong [School of Environment and Natural Resources, Renmin University of China, Beijing (China); Shi, Hanchang [School of Environment, Tsinghua University, Beijing (China); Long, Feng, E-mail: longf04@ruc.edu.cn [School of Environment and Natural Resources, Renmin University of China, Beijing (China)

    2016-01-28

    A universal sandwich-like immunoassay strategy based on quantum-dots immunoprobe (QD-labeled anti-mouse IgG antibody) was developed for rapid and ultrasensitive detection of small molecules. A portable and reusable optofluidic nano-biosensing platform was applied to investigate the sandwich-like immunoassay mechanism and format of small molecules, as well as the binding kinetics between QD immunoprobe and anti-small molecule antibody. A two-step immunoassay method that involves pre-incubation mixture of different concentration of small molecule and anti-small molecule antibody, and subsequent introduction of QD immunoprobe into the optofluidic cell was conducted for small molecule determination. Compared with the one-step immunoassay method, the two-step immunoassay method can obtain higher fluorescence signal and higher sensitivity index, thus improving the nano-biosensing performance. Based on the proposed strategy, two mode targets, namely, microcystin-LR (MC-LR) and Bisphenol A (BPA) were tested with high sensitivity, rapidity, and ease of use. A higher concentration of small molecules in the sample led to less anti-small molecule antibody bound with antigen-carrier protein conjugate immobilized onto the sensor surface, and less QD immunoprobes bound with anti-small molecule antibody. This phenomenon lowered the fluorescence signal detected by nano-biosensing platform. Under optimal operating conditions, MC-LR and BPA exhibited a limit of detection of 0.003 and 0.04 μg/L, respectively. The LODs were better than those of the indirect competitive immunoassay method for small molecules via Cy5.5-labeled anti-small molecule antibody. The proposed QD-based sandwich-like immunoassay strategy was evaluated in spiked water samples, and showed good recovery, precision and accuracy without complicated sample pretreatments. All these results demonstrate that the new detection strategy could be readily applied to the other trace small molecules in real water samples

  12. False-positive ethyl glucuronide immunoassay screening caused by a propyl alcohol-based hand sanitizer.

    Science.gov (United States)

    Arndt, Torsten; Grüner, Joachim; Schröfel, Stefanie; Stemmerich, Karsten

    2012-11-30

    Urine ethyl glucuronide (EtG) is considered as a specific marker of recent ethanol consumption. We describe false-positive DRI(®) EIA EtG enzyme immunoassay results caused by propyl glucuronides in urine after using a propanol-based hand sanitizer. EtG screening was done with the DRI(®) EIA EtG assay (Microgenics), using a cut-off of 0.5 mg/L as recommended by the manufacturer and of 0.1 mg/L as demanded by the German Regulations for Reissuing Drivers Licenses. Confirmatory EtG analysis was done with the ClinMass(®) EtG LC-MS/MS testkit (Recipe), extended by the mass transitions 235.1→75.1, 235.1→85.1, and 235.1→113.1 for the detection of the 1- and 2-propyl glucuronides. Self-experiments were done by staff members of our lab (n=7), using 3 mL Sterillium(®) Classic Pure (30 g/100 g 1-propanol and 45 g/100 g 2-propanol) for hand sanitation every quarter of an hour for 8 h according to DIN EN 1500:2011-05 with and without an exhauster and by passive inhalation of the sanitizer vapor. Spot urine samples were taken immediately before and up to 24 h after the first sanitizer use. False-positive immunoassay results of up to 4 mg/L or 2.3 mg/g creatinine were obtained after normal use of the sanitizer and also after passive inhalation of the sanitizer vapor (up to 0.89 mg/L or 0.61 mg/g). Immunoassay results were positive even after 4-fold use of the sanitizer (up to 0.14 mg/L or 0.38 mg/g) and up to 6 h after the last sanitizer contact (maximum 0.63 mg/L and 0.33 mg/g for sanitizer users and 0.25 mg/g after passive inhalation). Spiking of EtG-free urine with 1-propyl glucuronide (Athena Environmental Sciences) between 0.05 and 10 mg/L clearly demonstrated a cross reaction of the immunoassay of approx. 10% as compared to EtG. LC-MS/MS of urines with a positive immunoassay EtG result did not show EtG signals, but distinct signals of 1-propyl glucuronide (n-propyl glucuronide) and 2-propyl glucuronide (iso-propyl glucuronide). An exhauster effectively prevented

  13. Magnetic bead and gold nanoparticle probes based immunoassay for β-casein detection in bovine milk samples.

    Science.gov (United States)

    Li, Y S; Meng, X Y; Zhou, Y; Zhang, Y Y; Meng, X M; Yang, L; Hu, P; Lu, S Y; Ren, H L; Liu, Z S; Wang, X R

    2015-04-15

    In this work, a double-probe based immunoassay was developed for rapid and sensitive determination of β-casein in bovine milk samples. In the method, magnetic beads (MBs), employed as supports for the immobilization of anti-β-casein polyclonal antibody (PAb), were used as the capture probe. Colloidal gold nanoparticles (AuNPs), employed as a bridge for loading anti-β-casein monoclonal antibody (McAb) and horseradish peroxidase (HRP), were used as the amplification probe. The presence of β-casein causes the sandwich structures of MBs-PAb-β-casein-McAb-AuNPs through the interaction between β-casein and the anti-β-casein antibodies. The HRP, used as an enzymatic-amplified tracer, can catalytically oxidize the substrate 3,3',5,5'-tetramethylbenzidine (TMB), generating optical signals that are proportional to the quantity of β-casein. The linear range of the immunoassay was from 6.5 to 1520ngmL(-1). The limit of detection (LOD) was 4.8ngmL(-1) which was 700 times lower than that of MBs-antibody-HRP based immunoassay and 6-7 times lower than that from the microplate-antibody-HRP based assay. The recoveries of β-casein from bovine milk samples were from 95.0% to 104.3% that had a good correlation coefficient (R(2)=0.9956) with those obtained by an official standard Kjeldahl method. For higher sensitivity, simple sample pretreatment and shorter time requirement of the antigen-antibody reaction, the developed immunoassay demonstrated the viability for detection of β-casein in bovine milk samples. Copyright © 2014. Published by Elsevier B.V.

  14. Comparison of Immunoassay methods for T3, T4 and TSH

    International Nuclear Information System (INIS)

    Alonso Rodríguez, Celia A.

    2016-01-01

    Measurements of T3, T4 and TSH have been considered very important in the diagnosis and monitoring of thyroid diseases both overt and subclinical. These subclinical diseases are actively seeking for years, both in healthy patients and hospitalized for other illnesses; and in the population over 35 years, especially women, in health checkups. The active search for these diseases requires the use of rapid and reliable techniques; that can be developed massively, with good level of detectability and comparable. The overall objective is to present the evaluation of different immunoassay techniques with respect to the RIA and IRMA: ELISA, chemiluminescence, Amplified Chemiluminescence, electrochemiluminescence Immunofluorescence. Compare including automatic methods and analyze the cost and feasibility of them for laboratory immunoassay. ELISA colorimetric technique for dosing was comparable to RIA T4, not for T3. Chemiluminescence (AMERLITE) compared to dosing RIA and IRMA T4 to TSH proved to be valid for both. Amplified Chemiluminescence (Immulite) compared to IRMA for TSH was no significant difference. Electrochemiluminescence (Elecsys 2010) compared to T3 and T4 RIA and IRMA for TSH, no significant differences for T4 and TSH; but no variation to T3. Immunofluorescence (AIA-600) used to compare with RIA for T3 and T4, and TSH IRMA, no significant differences for the measured analytes. Benchmarking of automatic methods suggests that the most thrifty of trials is Immunofluorescence the AIA-600, regarding calibration and control, programming time, randomization and the ability to save the value of the fluorescence deferred calculations for tests without valid at the time of realizing calibration. Analyzing the cost and feasibility of these methods for laboratory immunoassay, we must consider that their characteristics electrochemiluminescence is the fastest, but its price is prohibitive for our health systems. The AIA-600 appears to be the method of choice for its

  15. Development and analytical performance of a new ARCHITECT automated dipeptidyl peptidase-4 immunoassay

    Directory of Open Access Journals (Sweden)

    Philip M. Hemken

    2017-12-01

    Full Text Available Background: Dipeptidyl peptidase-4 (DPP-4 may be a suitable biomarker to identify people with severe asthma who have greater activation of the interleukin-13 (IL-13 pathway and may therefore benefit from IL-13-targeted treatments. We report the analytical performance of an Investigational Use Only immunoassay and provide data on the biological range of DPP-4 concentrations. Methods: We assessed assay performance, utilising analyses of precision, linearity and sensitivity; interference from common endogenous assay interferents, and from asthma and anti-diabetic medications, were also assessed. The assay was used to measure the range of serum DPP-4 concentrations in healthy volunteers and subjects with diabetes and severe, uncontrolled asthma. Results: The total precision of DPP-4 concentration measurement (determined using percentage coefficient of variation was ≤5% over 20 days. Dilution analysis yielded linear results from 30 to 1305 ng/mL; the limit of quantitation was 19.2 ng/mL. No notable endogenous or drug interferences were observed at the expected therapeutic concentration. Median DPP-4 concentrations in healthy volunteers and subjects with asthma or Type 1 diabetes were assessed, with concentrations remaining similar in subjects with diabetes and asthma across different demographics. Conclusion: These analyses indicate that the ARCHITECT DPP-4 Immunoassay is a reliable and robust method for measuring serum DPP-4 concentration. Keywords: Asthma, Automated immunoassay, Biomarker, Dipeptidyl peptidase-4, IL-13

  16. Floating Chip Mounting System Driven by Repulsive Force of Permanent Magnets for Multiple On-Site SPR Immunoassay Measurements

    Science.gov (United States)

    Horiuchi, Tsutomu; Tobita, Tatsuya; Miura, Toru; Iwasaki, Yuzuru; Seyama, Michiko; Inoue, Suzuyo; Takahashi, Jun-ichi; Haga, Tsuneyuki; Tamechika, Emi

    2012-01-01

    We have developed a measurement chip installation/removal mechanism for a surface plasmon resonance (SPR) immunoassay analysis instrument designed for frequent testing, which requires a rapid and easy technique for changing chips. The key components of the mechanism are refractive index matching gel coated on the rear of the SPR chip and a float that presses the chip down. The refractive index matching gel made it possible to optically couple the chip and the prism of the SPR instrument easily via elastic deformation with no air bubbles. The float has an autonomous attitude control function that keeps the chip parallel in relation to the SPR instrument by employing the repulsive force of permanent magnets between the float and a float guide located in the SPR instrument. This function is realized by balancing the upward elastic force of the gel and the downward force of the float, which experiences a leveling force from the float guide. This system makes it possible to start an SPR measurement immediately after chip installation and to remove the chip immediately after the measurement with a simple and easy method that does not require any fine adjustment. Our sensor chip, which we installed using this mounting system, successfully performed an immunoassay measurement on a model antigen (spiked human-IgG) in a model real sample (non-homogenized milk) that included many kinds of interfering foreign substances without any sample pre-treatment. The ease of the chip installation/removal operation and simple measurement procedure are suitable for frequent on-site agricultural, environmental and medical testing. PMID:23202030

  17. Direct biosensor immunoassays for the detection of nonmilk proteins in milk powder

    NARCIS (Netherlands)

    Haasnoot, W.; Olieman, K.; Cazemier, G.; Verheijen, R.

    2001-01-01

    The low prices of some nonmilk proteins make them attractive as potential adulterants in dairy products. An optical biosensor (BIACORE 3000) was used to develop a direct and combined biosensor immunoassay (BIA) for the simultaneous detection of soy, pea, and soluble wheat proteins in milk powders.

  18. A competitive chemiluminescence enzyme immunoassay for rapid and sensitive determination of enrofloxacin

    Science.gov (United States)

    Yu, Fei; Wu, Yongjun; Yu, Songcheng; Zhang, Huili; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B.

    With alkaline phosphatase (ALP)-adamantane (AMPPD) system as the chemiluminescence (CL) detection system, a highly sensitive, specific and simple competitive chemiluminescence enzyme immunoassay (CLEIA) was developed for the measurement of enrofloxacin (ENR). The physicochemical parameters, such as the chemiluminescent assay mediums, the dilution buffer of ENR-McAb, the volume of dilution buffer, the monoclonal antibody concentration, the incubation time, and other relevant variables of the immunoassay have been optimized. Under the optimal conditions, the detection linear range of 350-1000 pg/mL and the detection limit of 0.24 ng/mL were provided by the proposed method. The relative standard deviations were less than 15% for both intra and inter-assay precision. This method has been successfully applied to determine ENR in spiked samples with the recovery of 103%-96%. It showed that CLEIA was a good potential method in the analysis of residues of veterinary drugs after treatment of related diseases.

  19. Screening for cocaine on Euro banknotes by a highly sensitive enzyme immunoassay.

    Science.gov (United States)

    Abdelshafi, Nahla A; Panne, Ulrich; Schneider, Rudolf J

    2017-04-01

    This study focused on quantitative detection of cocaine on Euro banknotes in Germany. A sensitive direct competitive immunoassay was developed and optimized with a limit of detection (LOD) of 5.6ng/L. Exhaustive cocaine extraction by solvent was tested using different methanol concentrations and buffered solutions. Cross-reactivity studies were performed to determine the degree of interference of cocaine metabolites with the immunoassay. Sixty-five Euro banknotes obtained from different districts in Berlin were evaluated. A 100% contamination frequency with cocaine was detected. A comparison between the amount of cocaine extracted by cotton swabbing of one square centimeter of the banknote showed a good correlation for lower contamination levels. This assay showed high sensitivity of detecting pg of cocaine per 1cm 2 of one banknote by swabbing 1cm 2 : 0, 14, and 21pg/cm 2 . Moreover, three notes of different denominations revealed high cocaine concentration; 1.1mg/note, and twice 55µg/note. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Tuberculin purified protein derivative (PPD) immunoassay as an in vitro alternative assay for identity and confirmation of potency.

    Science.gov (United States)

    Ho, Mei M; Kairo, Satnam K; Corbel, Michael J

    2006-01-01

    Tuberculin purified protein derivative (PPD) currently can only be standardised by delayed hypersensitivity skin reactions in sensitised guinea pigs. An in vitro dot blot immunoassay was developed for both identity and confirmation of potency estimation of PPD. Polyclonal antibodies (mainly IgG) were generated and immunoreacted with human, bovine and, to lesser extent, avian PPD preparations. Combining size exclusion chromatography (FPLC-SEC) and dot blot immunoassay, the results showed that PPD preparations were mixtures of very heterogeneous tuberculoproteins ranging in size from very large aggregates to very small degraded molecules. All individual fractions of PPD separated by size were immunoreactive, although those of the largest molecular sizes appeared the most immunoreactive in this in vitro dot blot immunoassay. This method is very sensitive and specific to tuberculoproteins and can be an in vitro alternative for the in vivo intradermal skin assay which uses guinea pigs for identity of PPD preparations. Although the capacity of PPD to elicit cell-mediated immune responses on intradermal testing has to be confirmed by in vivo assay, the dot blot immunoassay offers a rapid, sensitive and animal-free alternative to in vivo testing for confirming the identity of PPD preparations with appropriate potencies. This alternative assay would be particularly useful for national regulatory laboratories for confirming the data of manufacturers and thus reducing the use of animals.

  1. Development of Indirect Competitive Immuno-Assay Method Using SPR Detection for Rapid and Highly Sensitive Measurement of Salivary Cortisol Levels

    International Nuclear Information System (INIS)

    Tahara, Yusuke; Huang, Zhe; Kiritoshi, Tetsuro; Onodera, Takeshi; Toko, Kiyoshi

    2014-01-01

    The monitoring of salivary cortisol as a key biomarker of an individual’s stress response has been increasingly focused on. This paper describes the development of a novel cortisol immuno-assay method based on an indirect competitive method using a commercially available surface plasmon resonance instrument. The surface of an Au chip was modified with PEG6-COOH aromatic dialkanethiol self-assembled monolayers and hydrocortisone 3-(O-carboxymethyl) oxime (hydrocortisone 3-CMO) as a cortisol analog. A detection limit of 38 ppt range with a measurement range of 10 ppt–100 ppb was accomplished without the incubation of a mixing solution consisting of standard cortisol and an anti-cortisol antibody, and the time for quantification of cortisol concentration was 8 min from the sample injection. We experimentally compared our immuno-assay with a commercialized salivary cortisol enzyme-linked immunosorbent assay (ELISA) kit using human saliva samples. It was found that the results obtained by the cortisol immuno-assay had a good correlation with those obtained by ELISA assay (R = 0.96). Our findings indicate the potential utility of the cortisol immuno-assay for measurements of human salivary cortisol levels.

  2. Development of Indirect Competitive Immuno-Assay Method Using SPR Detection for Rapid and Highly Sensitive Measurement of Salivary Cortisol Levels

    Energy Technology Data Exchange (ETDEWEB)

    Tahara, Yusuke; Huang, Zhe; Kiritoshi, Tetsuro [Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka (Japan); Onodera, Takeshi [Research and Development Center for Taste and Odor Sensing, Kyushu University, Fukuoka (Japan); Toko, Kiyoshi, E-mail: toko@ed.kyushu-u.ac.jp [Graduate School of Information Science and Electrical Engineering, Kyushu University, Fukuoka (Japan); Research and Development Center for Taste and Odor Sensing, Kyushu University, Fukuoka (Japan)

    2014-05-30

    The monitoring of salivary cortisol as a key biomarker of an individual’s stress response has been increasingly focused on. This paper describes the development of a novel cortisol immuno-assay method based on an indirect competitive method using a commercially available surface plasmon resonance instrument. The surface of an Au chip was modified with PEG6-COOH aromatic dialkanethiol self-assembled monolayers and hydrocortisone 3-(O-carboxymethyl) oxime (hydrocortisone 3-CMO) as a cortisol analog. A detection limit of 38 ppt range with a measurement range of 10 ppt–100 ppb was accomplished without the incubation of a mixing solution consisting of standard cortisol and an anti-cortisol antibody, and the time for quantification of cortisol concentration was 8 min from the sample injection. We experimentally compared our immuno-assay with a commercialized salivary cortisol enzyme-linked immunosorbent assay (ELISA) kit using human saliva samples. It was found that the results obtained by the cortisol immuno-assay had a good correlation with those obtained by ELISA assay (R = 0.96). Our findings indicate the potential utility of the cortisol immuno-assay for measurements of human salivary cortisol levels.

  3. Single biosensor immunoassay for the detection of five aminoglycosides in reconstituted skimmed milk

    NARCIS (Netherlands)

    Haasnoot, W.; Cazemier, G.; Koets, M.; Amerongen, van A.

    2003-01-01

    The application of an optical biosensor (Biacore 3000), with four flow channels (Fcs), in combination with a mixture of four specific antibodies resulted in a competitive inhibition biosensor immunoassay (BIA) for the simultaneous detection of the five relevant aminoglycosides in reconstituted

  4. Compact quantum dot-antibody conjugates for FRET immunoassays with subnanomolar detection limits

    Science.gov (United States)

    Mattera, Lucia; Bhuckory, Shashi; Wegner, K. David; Qiu, Xue; Agnese, Fabio; Lincheneau, Christophe; Senden, Tim; Djurado, David; Charbonnière, Loïc J.; Hildebrandt, Niko; Reiss, Peter

    2016-05-01

    A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post-functionalization with a heterobifunctional crosslinker, containing a lipoic acid group and a maleimide function, enabled the subsequent coupling to sulfhydryl groups of proteins. This was demonstrated by QD conjugation with fragmented antibodies (F(ab)). The obtained F(ab)-QD conjugates range among the smallest antibody-functionalized nanoprobes ever reported, with a hydrodynamic diameter coating for FRET could be demonstrated by an 6.2 and 2.5 fold improvement of the limit of detection (LOD) for PSA compared to commercially available hydrophilic QDs emitting at 605 and 705 nm, respectively. While the commercial QDs contain identical inorganic cores responsible for their fluorescence, they are coated with a comparably thick amphiphilic polymer layer leading to much larger hydrodynamic diameters (>26 nm without biomolecules). The LODs of 0.8 and 3.7 ng mL-1 obtained in 50 μL serum samples are below the clinical cut-off level of PSA (4 ng mL-1) and demonstrate their direct applicability in clinical diagnostics.A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post-functionalization

  5. Chemiluminescence immunoassay for prostate-specific antigen

    International Nuclear Information System (INIS)

    Zhang Xuefeng; Liu Yibing; Jia Juanjuan; Xu Wenge; Li Ziying; Chen Yongli; Han Shiquan

    2008-01-01

    The chemiluminescence immunoassay (CLIA) for serum total prostate-specific antigen (T-PSA) was developed. The reaction of luminol with hydrogen peroxide was introduced into this chemiluminescence system. The detection limit is established as 0.12 μg/L (n=10, mean of zero standard + 2SD) and the analytical recovery of PSA is 83.8%-118.7%. The intra-assay and inter-assay CVs vary from 4.4%-5.0% and 6.2%-11.7%, respectively. The experimental correlation coefficient of dilution is found to be 0.999. Compared with immunoradiometric assay (IRMA) kits, the correlative equation is y=1.07x+0.68, and correlation coefficient r=0.97. The standard range for the method is 1.5-80 μg/L, and it presents good linearity. (authors)

  6. Inkjet-printed point-of-care immunoassay on a nanoscale polymer brush enables subpicomolar detection of analytes in blood

    Science.gov (United States)

    Joh, Daniel Y.; Hucknall, Angus M.; Wei, Qingshan; Mason, Kelly A.; Lund, Margaret L.; Fontes, Cassio M.; Hill, Ryan T.; Blair, Rebecca; Zimmers, Zackary; Achar, Rohan K.; Tseng, Derek; Gordan, Raluca; Freemark, Michael; Ozcan, Aydogan; Chilkoti, Ashutosh

    2017-08-01

    The ELISA is the mainstay for sensitive and quantitative detection of protein analytes. Despite its utility, ELISA is time-consuming, resource-intensive, and infrastructure-dependent, limiting its availability in resource-limited regions. Here, we describe a self-contained immunoassay platform (the “D4 assay”) that converts the sandwich immunoassay into a point-of-care test (POCT). The D4 assay is fabricated by inkjet printing assay reagents as microarrays on nanoscale polymer brushes on glass chips, so that all reagents are “on-chip,” and these chips show durable storage stability without cold storage. The D4 assay can interrogate multiple analytes from a drop of blood, is compatible with a smartphone detector, and displays analytical figures of merit that are comparable to standard laboratory-based ELISA in whole blood. These attributes of the D4 POCT have the potential to democratize access to high-performance immunoassays in resource-limited settings without sacrificing their performance.

  7. Evaluation of field test kits including immunoassays for the detection of contaminants in soil and water

    International Nuclear Information System (INIS)

    Waters, L.C.; Smith, R.R.; Counts, R.W.; Stewart, J.H.; Jenkins, R.A.

    1993-01-01

    Effective field test methods are needed for hazardous waste site characterization and remediation. Useful field methods should be rapid, analyte-specific, cost-effective and accurate in the concentration range at which the analyte is regulated. In this study, field test kits for polychlorinated biphenyls (PCBs), mercury, lead and nitrate were evaluated with reference to these criteria. PCBs and mercury, in soils, were analyzed by immunoassay. Ionic lead and nitrate, in water, were measured chemically using test strips. Except for lead, each analyte was measured in both spiked and actual field samples. Twenty to 40 samples per day can be analyzed with the immunoassays and even more with the strip tests. The sensitivity of the immunoassays is in the 1-3 ppM range. Nitrate was consistently detected at ≥5 ppM; lead ions at ≥20 ppM. Results obtained using these methods compared favorably with those obtained by standard laboratory methods. In addition to being useful field screening methods, these kits can be used in the laboratory to sort out negative samples and/or to define proper dilutions for positive samples requiring further analysis

  8. Homogeneous immunoassay for human IgG using oriented hen egg IgY immobilized on gold sol nanoparticles

    International Nuclear Information System (INIS)

    Yeritsyan, H.E.; Gasparyan, V.K.

    2012-01-01

    Homogeneous immunoassays using (red) gold nanoparticles represent an attractive detection scheme because of the option of photometric readout. We have applied oriented immobilization of hen egg immunoglobulin Y (IgY) on gold nanoparticles when developing a homogeneous immunoassay for human IgG. In oriented immobilization, as opposed to random immobilization, the antigen binding capabilities of the antibodies are retained. It is shown that such immunoassay has significantly better sensitivity in comparison with methods based on conventional immobilization of affinity-purified antibodies. It is also shown that hen egg IgY is better suited than rabbit antibodies, because much more antibody can be immobilized on gold nanoparticles without any destabilization, probably because of the more acidic nature of these antibodies. In addition, hen egg IgY can be supplied in higher quantity and can be prepared more easily than IgG from rabbits. Bleeding and slaughtering of animals is not needed. The assay presented here has a wide detection range (30-500 ng. mL -1 ) and a limit of detection as low as 30 ng. mL -1 of human IgG. (author)

  9. The value function as a criterion of analysis in separation technologies

    International Nuclear Information System (INIS)

    Peculea, Marius

    2005-01-01

    Production costs of heavy water are described by two functions: φ(ε), the energy function which represents the variable costs and φ(τ), the technologic function which represents the stable costs. The Dirac value function related to the circulation in the separation cascade allows calculating φ(ε) and consequently the technologic function may be represented in relation to the specific separation process. This representation allows the qualitative analysis of different separation processes or, for a given process, provides the analysis of different technological solutions which were worked out. An example is given referring to the analysis of heavy water technologies of separation through the dual temperature process of H 2 O-H 2 S isotopic exchange

  10. Color encoded microbeads-based flow cytometric immunoassay for polycyclic aromatic hydrocarbons in food

    International Nuclear Information System (INIS)

    Meimaridou, Anastasia; Haasnoot, Willem; Noteboom, Linda; Mintzas, Dimitrios; Pulkrabova, Jana; Hajslova, Jana; Nielen, Michel W.F.

    2010-01-01

    Food contamination caused by chemical hazards such as persistent organic pollutants (POPs) is a worldwide public health concern and requires continuous monitoring. The chromatography-based analysis methods for POPs are accurate and quite sensitive but they are time-consuming, laborious and expensive. Thus, there is a need for validated simplified screening tools, which are inexpensive, rapid, have automation potential and can detect multiple POPs simultaneously. In this study we developed a flow cytometry-based immunoassay (FCIA) using a color-encoded microbeads technology to detect benzo[a]pyrene (BaP) and other polycyclic aromatic hydrocarbons (PAHs) in buffer and food extracts as a starting point for the future development of rapid multiplex assays including other POPs in food, such as polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs). A highly sensitive assay for BaP was obtained with an IC 50 of 0.3 μg L -1 using a monoclonal antibody (Mab22F12) against BaP, similar to the IC 50 of a previously described enzyme-linked immunosorbent assay (ELISA) using the same Mab. Moreover, the FCIA was 8 times more sensitive for BaP compared to a surface plasmon resonance (SPR)-based biosensor immunoassay (BIA) using the same reagents. The selectivity of the FCIAs was tested, with two Mabs against BaP for 25 other PAHs, including two hydroxyl PAH metabolites. Apart from BaP, the FCIAs can detect PAHs such as indenol[1,2,3-cd]pyrene (IP), benz[a]anthracene (BaA), and chrysene (CHR) which are also appointed by the European Food Safety Authority (EFSA) as suitable indicators of PAH contamination in food. The FCIAs results were in agreement with those obtained with gas chromatography-mass spectrometry (GC-MS) for the detection of PAHs in real food samples of smoked carp and wheat flour and has great potential for the future routine application of this assay in a simplex or multiplex format in combination with simplified extraction procedure which are

  11. Rapid Salmonella detection in experimentally inoculated equine faecal and veterinary hospital environmental samples using commercially available lateral flow immunoassays.

    Science.gov (United States)

    Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S

    2015-01-01

    Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.

  12. Tumor specific lung cancer diagnostics with multiplexed FRET immunoassays

    Science.gov (United States)

    Geißler, D.; Hill, D.; Löhmannsröben, H.-G.; Thomas, E.; Lavigne, A.; Darbouret, B.; Bois, E.; Charbonnière, L. J.; Ziessel, R. F.; Hildebrandt, N.

    2010-02-01

    An optical multiplexed homogeneous (liquid phase) immunoassay based on FRET from a terbium complex to eight different fluorescent dyes is presented. We achieved highly sensitive parallel detection of four different lung cancer specific tumor markers (CEA, NSE, SCC and CYFRA21-1) within a single assay and show a proof-of-principle for 5- fold multiplexing. The method is well suited for fast and low-cost miniaturized point-of-care testing as well as for highthroughput screening in a broad range of in-vitro diagnostic applications.

  13. Implementation of a rapid HIT immunoassay at a university hospital - Retrospective analysis of HIT laboratory orders in patients with thrombocytopenia.

    Science.gov (United States)

    Black, Anne; Heimerl, Susanne; Oertli, Linnéa; Wilczek, Wolf; Greinacher, Andreas; Spannagl, Michael; Herr, Wolfgang; Hart, Christina

    2017-10-01

    Heparin-induced thrombocytopenia (HIT) is a rare cause of thrombocytopenia and a potentially life-threatening adverse drug reaction. Clinical overdiagnosis of HIT results in costly laboratory tests and anticoagulation. Criteria and algorithms for diagnosis are established, but their translation into clinical practice is still challenging. In a retrospective approach we studied all HIT related laboratory test requests within four years and evaluated data before (1st period, 24month) and after (2nd period, 24month) replacing particle gel immunoassay (PaGIA) and enzyme-linked immunosorbent assay (ELISA) by a chemiluminescent immunoassay (CLIA). HIT was confirmed by heparin-induced platelet activation (HIPA) test. Clinical pretest probability for HIT using an implemented simplified 4Ts score and platelet count were evaluated. Costs for laboratory tests and alternative anticoagulation were calculated. In 1850 patients with suspected HIT, 2327 laboratory orders were performed. In 87.2% of these orders an intermediate/high simplified 4Ts score was found. Thrombocytopenia was present in 87.1%. After replacing PaGIA and ELISA by CLIA the number of immunological and functional laboratory tests was reduced by 38.2%. The number of positive HIT immunoassays declined from 22.6% to 6.0%, while the number of positive HIPA tests among positive immunological tests increased by 19%. Altogether, acute HIT was confirmed in 59 patients. A decline in the use of alternative anticoagulants was observed in the 2nd period. Our study shows that in a university hospital setting HIT is well-known, but diagnosis requires a precise laboratory confirmation. Replacing PaGIA and ELISA by CLIA did not influence laboratory order behavior but results in reduced overall costs for laboratory diagnostics and alternative anticoagulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Polyethylene imine/graphene oxide layer-by-layer surface functionalization for significantly improved limit of detection and binding kinetics of immunoassays on acrylate surfaces.

    Science.gov (United States)

    Miyazaki, Celina M; Mishra, Rohit; Kinahan, David J; Ferreira, Marystela; Ducrée, Jens

    2017-10-01

    Antibody immobilization on polymeric substrates is a key manufacturing step for microfluidic devices that implement sample-to-answer automation of immunoassays. In this work, a simple and versatile method to bio-functionalize poly(methylmethacrylate) (PMMA), a common material of such "Lab-on-a-Chip" systems, is proposed; using the Layer-by-Layer (LbL) technique, we assemble nanostructured thin films of poly(ethylene imine) (PEI) and graphene oxide (GO). The wettability of PMMA surfaces was significantly augmented by the surface treatment with (PEI/GO) 5 film, with an 81% reduction of the contact angle, while the surface roughness increased by 600%, thus clearly enhancing wettability and antibody binding capacity. When applied to enzyme-linked immunosorbent assays (ELISAs), the limit of detection of PMMA surface was notably improved from 340pgmL -1 on commercial grade polystyrene (PS) and 230pgmL -1 on plain PMMA surfaces to 130pgmL -1 on (PEI/GO) 5 treated PMMA. Furthermore, the accelerated antibody adsorption kinetics on the LbL films of GO allowed to substantially shorten incubation times, e.g. for anti-rat IgG adsorption from 2h down to 15min on conventional and treated surfaces, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Magnetofluorescent nanocomposites and quantum dots used for optimal application in magnetic fluorescence-linked immunoassay.

    Science.gov (United States)

    Tsai, H Y; Li, S Y; Fuh, C Bor

    2018-03-01

    Magnetofluorescent nanocomposites with optimal magnetic and fluorescent properties were prepared and characterized by combining magnetic nanoparticles (iron oxide@polymethyl methacrylate) with fluorescent nanoparticles (rhodamine 6G@mSiO 2 ). Experimental parameters were optimized to produce nanocomposites with high magnetic susceptibility and fluorescence intensity. The detection of a model biomarker (alpha-fetoprotein) was used to demonstrate the feasibility of applying the magnetofluorescent nanocomposites combined with quantum dots and using magnetic fluorescence-linked immunoassay. The magnetofluorescent nanocomposites enable efficient mixing, fast re-concentration, and nanoparticle quantization for optimal reactions. Biofunctional quantum dots were used to confirm the alpha-fetoprotein (AFP) content in sandwich immunoassay after mixing and washing. The analysis time was only one third that required in ELISA. The detection limit was 0.2 pg mL -1 , and the linear range was 0.68 pg mL -1 -6.8 ng mL -1 . This detection limit is lower, and the linear range is wider than those of ELISA and other methods. The measurements made using the proposed method differed by less than 13% from those obtained using ELISA for four AFP concentrations (0.03, 0.15, 0.75, and 3.75 ng mL -1 ). The proposed method has a considerable potential for biomarker detection in various analytical and biomedical applications. Graphical abstract Magnetofluorescent nanocomposites combined with fluorescent quantum dots were used in magnetic fluorescence-linked immunoassay.

  16. Development of an immunomagnetic bead-based time-resolved fluorescence immunoassay for rapid determination of levels of carcinoembryonic antigen in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Hou Jingyuan; Liu Tiancai; Lin Guanfeng; Li Zhixiong; Zou Liping; Li Ming [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515 (China); Wu Yingsong, E-mail: wg@fimmu.com [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515 (China)

    2012-07-13

    Highlights: Black-Right-Pointing-Pointer Magnetic beads was used as the solid phase for TRFIA. Black-Right-Pointing-Pointer The linearity range was broadened greatly compared with conventional TRFIA method. Black-Right-Pointing-Pointer The analysis time was significantly shorter compared with conventional TRFIA method. Black-Right-Pointing-Pointer This method could be developed for practical clinical detections of tumor-associated antigens. - Abstract: A novel immunoassay for the determination of tumor markers in human serum was established by combining a time-resolved fluoroimmunoassay (TRFIA) and immunomagnetic separation. Based on a sandwich-type immunoassay format, analytes in samples were captured by magnetic beads coated with one monoclonal antibody and 'sandwiched' by another monoclonal antibody labeled with europium chelates. The immunocomplex was separated and washed by exposure to a magnetic field and treatment with enhancement solution; fluorescence was then measured according to the number of europium ions dissociated. Levels of the model analyte, carcinoembryonic antigen (CEA), were determined in a linear range (1-1000 ng mL{sup -1}) with a limit of detection of 0.5 ng mL{sup -1} under optimal conditions. The reproducibility, recovery, and specificity of the immunoassay were demonstrated to be acceptable. To evaluate this novel assay for clinical applications, 239 serum samples were evaluated. Compared with the conventional TRFIA and chemiluminescence immunoassay (CLIA), the correlation coefficients of the developed immunoassay were 0.985 and 0.975, respectively. These results showed good correlation and confirmed that our method is feasible and could be used for the clinical determination of CEA (or other tumor antigens) in human serum.

  17. Alkaline phosphatase labeled SERS active sandwich immunoassay for detection of Escherichia coli

    Science.gov (United States)

    Bozkurt, Akif Goktug; Buyukgoz, Guluzar Gorkem; Soforoglu, Mehmet; Tamer, Ugur; Suludere, Zekiye; Boyaci, Ismail Hakki

    2018-04-01

    In this study, a sandwich immunoassay method utilizing enzymatic activity of alkaline phosphatase (ALP) on 5-bromo-4-chloro-3-indolyl phosphate (BCIP) for Escherichia coli (E. coli) detection was developed using surface enhanced Raman spectroscopy (SERS). For this purpose, spherical magnetic gold coated core-shell nanoparticles (MNPs-Au) and rod shape gold nanoparticles (Au-NRs) were synthesized and modified for immunomagnetic separation (IMS) of E. coli from the solution. In order to specify the developed method to ALP activity, Au-NRs were labeled with this enzyme. After successful construction of the immunoassay, BCIP substrate was added to produce the SERS-active product; 5-bromo-4-chloro-3-indole (BCI). A good linearity (R2 = 0.992) was established between the specific SERS intensity of BCI at 600 cm- 1 and logarithmic E. coli concentration in the range of 1.7 × 101-1.7 × 106 cfu mL- 1. LOD and LOQ values were also calculated and found to be 10 cfu mL- 1 and 30 cfu mL- 1, respectively.

  18. Rational design of Raman-labeled nanoparticles for a dual-modality, light scattering immunoassay on a polystyrene substrate.

    Science.gov (United States)

    Israelsen, Nathan D; Wooley, Donald; Hanson, Cynthia; Vargis, Elizabeth

    2016-01-01

    Surface-enhanced Raman scattering (SERS) is a powerful light scattering technique that can be used for sensitive immunoassay development and cell labeling. A major obstacle to using SERS is the complexity of fabricating SERS probes since they require nanoscale characterization and optical uniformity. The light scattering response of SERS probes may also be modulated by the substrate used for SERS analysis. A typical SERS substrate such as quartz can be expensive. Polystyrene is a cheaper substrate option but can decrease the SERS response due to interfering Raman emission peaks and high background fluorescence. The goal of this research is to develop an optimized process for fabricating Raman-labeled nanoparticles for a SERS-based immunoassay on a polystyrene substrate. We have developed a method for fabricating SERS nanoparticle probes for use in a light scattering immunoassay on a polystyrene substrate. The light scattering profile of both spherical gold nanoparticle and gold nanorod SERS probes were characterized using Raman spectroscopy and optical absorbance spectroscopy. The effects of substrate interference and autofluorescence were reduced by selecting a Raman reporter with a strong light scattering response in a spectral region where interfering substrate emission peaks are minimized. Both spherical gold nanoparticles and gold nanorods SERS probes used in the immunoassay were detected at labeling concentrations in the low pM range. This analytical sensitivity falls within the typical dynamic range for direct labeling of cell-surface biomarkers using SERS probes. SERS nanoparticle probes were fabricated to produce a strong light scattering signal despite substrate interference. The optical extinction and inelastic light scattering of these probes was detected by optical absorbance spectroscopy and Raman spectroscopy, respectively. This immunoassay demonstrates the feasibility of analyzing strongly enhanced Raman signals on polystyrene, which is an

  19. Silver nanoparticles deposited on graphene oxide for ultrasensitive surface-enhanced Raman scattering immunoassay of cancer biomarker.

    Science.gov (United States)

    Yang, Lin; Zhen, Shu Jun; Li, Yuan Fang; Huang, Cheng Zhi

    2018-06-14

    Graphene oxide (GO) exhibits distinctive Raman scattering features for its high frequency D (disordered) and tangential modes (G-band), which are characteristically sharp at 1580 cm-1 and 1350 cm-1, respectively, but are too weak for sensitive quantitation purposes. By depositing silver nanoparticles on the surface of GO in this contribution, both D and G bands of GO become enhanced. The enzyme label of this method controls the dissolution of silver nanoparticles on the surface of GO through hydrogen peroxide which is produced by the oxidation of the enzyme substrate. With the dissolution of the silver nanoparticles a greatly decreased SERS signal of GO was obtained. This strategy involves dual signal amplification of the enzyme and nanocomposites to improve the detection sensitivity. As a proof of concept, prostate specific antigen (PSA), a biomarker for prostate cancer, is successfully detected as a target by forming a sandwich structure in immunoassay. The SERS immunoassay possesses excellent analytical performance in the range 0.5 pg mL-1 to 500 pg mL-1 with a limit of detection of 0.23 pg mL-1, making the detection of PSA serum samples from prostate cancer patients satisfactory, demonstrating that the sensitive enzyme-assisted dissolved AgNPs SERS immunoassay of PSA has potential applications in clinical diagnosis.

  20. A competitive enzyme immunoassay for the quantitative detection of cocaine from banknotes and latent fingermarks.

    Science.gov (United States)

    van der Heide, Susan; Garcia Calavia, Paula; Hardwick, Sheila; Hudson, Simon; Wolff, Kim; Russell, David A

    2015-05-01

    A sensitive and versatile competitive enzyme immunoassay (cEIA) has been developed for the quantitative detection of cocaine in complex forensic samples. Polyclonal anti-cocaine antibody was purified from serum and deposited onto microtiter plates. The concentration of the cocaine antibody adsorbed onto the plates, and the dilution of the cocaine-HRP hapten were both studied to achieve an optimised immunoassay. The method was successfully used to quantify cocaine in extracts taken from both paper currency and latent fingermarks. The limit of detection (LOD) of 0.162ngmL(-1) achieved with the assay compares favourably to that of conventional chromatography-mass spectroscopy techniques, with an appropriate sensitivity for the quantification of cocaine at the low concentrations present in some forensic samples. The cEIA was directly compared to LC-MS for the analysis of ten UK banknote samples. The results obtained from both techniques were statistically similar, suggesting that the immunoassay was unaffected by cross-reactivity with potentially interfering compounds. The cEIA was used also for the detection of cocaine in extracts from latent fingermarks. The results obtained were compared to the cocaine concentrations detected in oral fluid sampled from the same individual. Using the cEIA, we have shown, for the first time, that endogeneously excreted cocaine can be detected and quantified from a single latent fingermark. Additionally, it has been shown that the presence of cocaine, at similar concentrations, in more than one latent fingermark from the same individual can be linked with those concentrations found in oral fluid. These results show that detection of drugs in latent fingermarks could directly indicate whether an individual has consumed the drug. The specificity and feasibility of measuring low concentrations of cocaine in complex forensic samples demonstrate the effectiveness and robustness of the assay. The immunoassay presents a simple and cost

  1. False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.

    Science.gov (United States)

    Katz, Alan R; Komeya, Alan Y; Tomas, Juval E

    2017-06-01

    We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.

  2. Targeted deposition of antibodies on a multiplex CMOS microarray and optimization of a sensitive immunoassay using electrochemical detection.

    Directory of Open Access Journals (Sweden)

    John Cooper

    2010-03-01

    Full Text Available The CombiMatrix ElectraSense microarray is a highly multiplex, complementary metal oxide semiconductor with 12,544 electrodes that are individually addressable. This platform is commercially available as a custom DNA microarray; and, in this configuration, it has also been used to tether antibodies (Abs specifically on electrodes using complementary DNA sequences conjugated to the Abs.An empirical method is described for developing and optimizing immunoassays on the CombiMatrix ElectraSense microarray based upon targeted deposition of polypyrrole (Ppy and capture Ab. This process was automated using instrumentation that can selectively apply a potential or current to individual electrodes and also measure current generated at the electrodes by an enzyme-enhanced electrochemical (ECD reaction. By designating groups of electrodes on the array for different Ppy deposition conditions, we determined that the sensitivity and specificity of a sandwich immunoassay for staphylococcal enterotoxin B (SEB is influenced by the application of different voltages or currents and the application time. The sandwich immunoassay used a capture Ab adsorbed to the Ppy and a reporter Ab labeled for fluorescence detection or ECD, and results from these methods of detection were different.Using Ppy deposition conditions for optimum results, the lower limit of detection for SEB using the ECD assay was between 0.003 and 0.01 pg/ml, which represents an order of magnitude improvement over a conventional enzyme-linked immunosorbant assay. In the absence of understanding the variables and complexities that affect assay performance, this highly multiplexed electrode array provided a rapid, high throughput, and empirical approach for developing a sensitive immunoassay.

  3. Determination of phospholipid transfer proteins in rat tissues by immunoassays

    International Nuclear Information System (INIS)

    Teerlink, T.

    1983-01-01

    Several quantitative immunoassays have been developed for two phospholipid transfer proteins from rat liver, i.e. the phosphatidylcholine transfer protein and the non-specific lipid transfer protein. The development of a double-antibody radioimmunoassay for the phosphatidylcholine transfer protein is described. The transfer protein was labelled with iodine-125 by the mild glucose oxidase-lactoperoxidase method. Although less than one tyrosine residue per molecule of transfer protein was labelled, only 20% of the labelled transfer protein was immunoprecipitable. This value could be increased to 80% by purifying the labelled protein by affinity chromatography on a column of anti-phosphatidylcholine transfer protein-IgG coupled to Sepharose 4B. The radioimmunoassay was used to determine the levels of phosphatidylcholine transfer protein in homogenates and 105 000 xg supernatants from various rat tissues as well as several Morris hepatomas. An enzyme immunoassay for the non-specific lipid transfer protein is also described. The antiserum that was raised especially by the author was cross-reactive with the non-specific lipid transfer protein present in 105 000 xg supernatants from human, mouse and bovine liver. The non-specific lipid transfer protein lost its immunoreactivity upon labelling with iodine-125 using different labelling techniques. Therefore, a regular radioimmunoassay could not be developed. The results of these different assays were compared. (Auth.)

  4. In-electrode vs. on-electrode: ultrasensitive Faraday cage-type electrochemiluminescence immunoassay.

    Science.gov (United States)

    Guo, Zhiyong; Sha, Yuhong; Hu, Yufang; Wang, Sui

    2016-03-28

    A new-concept of an "in-electrode" Faraday cage-type electrochemiluminescence immunoassay (ECLIA) method for the ultrasensitive detection of neurotensin (NT) was reported with capture antibody (Ab1)-nanoFe3O4@graphene (GO) and detector antibody (Ab2)&N-(4-aminobutyl)-N-ethylisoluminol (ABEI)@GO, which led to about 1000-fold improvement in sensitivity by extending the Helmholtz plane (OHP) of the proposed electrode assembly effectively.

  5. Functional fixedness in a technologically sparse culture.

    Science.gov (United States)

    German, Tim P; Barrett, H Clark

    2005-01-01

    Problem solving can be inefficient when the solution requires subjects to generate an atypical function for an object and the object's typical function has been primed. Subjects become "fixed" on the design function of the object, and problem solving suffers relative to control conditions in which the object's function is not demonstrated. In the current study, such functional fixedness was demonstrated in a sample of adolescents (mean age of 16 years) among the Shuar of Ecuadorian Amazonia, whose technologically sparse culture provides limited access to large numbers of artifacts with highly specialized functions. This result suggests that design function may universally be the core property of artifact concepts in human semantic memory.

  6. An anti-phospholipase A2 receptor quantitative immunoassay and epitope analysis in membranous nephropathy reveals different antigenic domains of the receptor.

    Directory of Open Access Journals (Sweden)

    Astrid Behnert

    Full Text Available The phospholipase A2 receptor (PLA2R was recently discovered as a target autoantigen in patients with idiopathic membranous nephropathy (IMN. Published evidence suggests that the autoantibodies directed towards a conformation dependent epitope are currently effectively detected by a cell based assay (CBA utilizing indirect immunofluorescence (IIF on tissue culture cells transfected with the PLA2R cDNA. Limitations of such IIF-CBA assays include observer dependent subjective evaluation of semi-quantitative test results and the protocols are not amenable to high throughput diagnostic testing. We developed a quantitative, observer independent, high throughput capture immunoassay for detecting PLA2R autoantibodies on an addressable laser bead immunoassay (ALBIA platform. Since reactive domains of PLA2R (i.e. epitopes could be used to improve diagnostic tests by using small peptides in various high throughput diagnostic platforms, we identified PLA2R epitopes that bound autoantibodies of IMN patients. These studies confirmed that inter-molecular epitope spreading occurs in IMN but use of the cognate synthetic peptides in immunoassays was unable to conclusively distinguish between IMN patients and normal controls. However, combinations of these peptides were able to effectively absorb anti-PLA2R reactivity in IIF-CBA and an immunoassay that employed a lysate derived from HEK cells tranfected with and overexpressing PLA2R. While we provide evidence of intermolecular epitope spreading, our data indicates that in addition to conformational epitopes, human anti-PLA2R reactivity in a commercially available CBA and an addressable laser bead immunoassay is significantly absorbed by peptides representing epitopes of PLA2R.

  7. Radio-immunoassays for glucagon-like peptides 1 and 2 (GLP-1 and GLP-2)

    DEFF Research Database (Denmark)

    Orskov, C; Holst, J J

    1987-01-01

    Gene-sequencing studies have shown that the glucagon precursor contains two additional glucagon-like sequences, the so-called glucagon-like peptides 1 and 2 (GLP-1 and GLP-2). We developed radio-immunoassays against synthetic peptides corresponding to these sequences. Antisera were raised in rabb...

  8. Monoclonal antibody-based broad-specificity immunoassay for monitoring organophosphorus pesticides in environmental water samples

    Science.gov (United States)

    The extensive use of organophosphorus pesticides (OPs) in agriculture and domestic settings can result in widespread water contamination. The development of easy-to-use and rapid-screening immunoassay methods in a class-selective manner is a topic of considerable environmental interest. In this wo...

  9. Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation

    NARCIS (Netherlands)

    Dittmer, W.U.; Kievit, de P.; Prins, M.W.J.; Vissers, J.L.M.; Mersch, M.E.C.; Martens, M.F.W.C.

    2008-01-01

    A rapid method for the sensitive detection of proteins using actuated magnetic particle labels, which are measured with a giant magneto-resistive (GMR) biosensor, is described. The technique involves a 1-step sandwich immunoassay with no fluid replacement steps. The various assay binding reactions

  10. Development of a simple extraction procedure for chlorpyrifos determination in food samples by immunoassay.

    Science.gov (United States)

    Gabaldón, J A; Maquieira, A; Puchades, R

    2007-02-28

    The suitability of immunoassay methodology for rapid and accurate determination of chlorpyrifos in vegetables was tested. The optimised ELISA detection limit was 0.32ng/ml, with a working range from 0.69 to 6.21ng/ml and an immunoassay test-mid point (IC(50)) of 2.08ng/ml. A rapid sample preparation procedure considering different parameters such as the amount of sample, volume of extractant, extraction time and dilution factor was optimised. The developed direct extraction (DE) and multiresidue (ME) standard procedures were performed in different fortified fresh and processed vegetable samples (tomato, bonnet pepper, bean, pea, asparagus, broccoli, watermelon, melon, lettuce, cucumber, celery and red pepper). Recoveries were in all cases in the whole range 85.2-108.9% for both DE and ME extracts. Also, the comparison of the results obtained by both immunochemical and chromatographic methods for spiked fruits and vegetables were good with a correlation coefficient (r) of 0.97.

  11. Accurate Point-of-Care Detection of Ruptured Fetal Membranes: Improved Diagnostic Performance Characteristics with a Monoclonal/Polyclonal Immunoassay

    Directory of Open Access Journals (Sweden)

    Linda C. Rogers

    2016-01-01

    Full Text Available Objective Accurate and timely diagnosis of rupture of membranes (ROM is imperative to allow for gestational age-specific interventions. This study compared the diagnostic performance characteristics between two methods used for the detection of ROM as measured in the same patient. Methods Vaginal secretions were evaluated using the conventional fern test as well as a point-of-care monoclonal/polyclonal immunoassay test (ROM Plus® in 75 pregnant patients who presented to labor and delivery with complaints of leaking amniotic fluid. Both tests were compared to analytical confirmation of ROM using three external laboratory tests. Diagnostic performance characteristics were calculated including sensitivity, specificity, positive predictive value (PPV, negative predictive value (NPV, and accuracy. Results Diagnostic performance characteristics uniformly favored ROM detection using the immunoassay test compared to the fern test: sensitivity (100% vs. 77.8%, specificity (94.8% vs. 79.3%, PPV (75% vs. 36.8%, NPV (100% vs. 95.8%, and accuracy (95.5% vs. 79.1%. Conclusions The point-of-care immunoassay test provides improved diagnostic accuracy for the detection of ROM compared to fern testing. It has the potential of improving patient management decisions, thereby minimizing serious complications and perinatal morbidity.

  12. Evaluation and comparison of radio-, fluorescence, and enzyme-linked immunoassays for serum thyroxine

    International Nuclear Information System (INIS)

    Kaplan, L.A.; Gau, N.; Fearn, J.; Steain, E.A.; Chen, I.W.; Maxon, H.; Volle, C.

    1981-01-01

    We have compared three analytical systems for the measurement of serum thyroxine: enzyme-linked immunoassay (EIA), fluorescent immunoassay (FIA) and a radioimmunoassay (RIA). These were evaluated with respect to their precision, accuracy, analytical sensitivity and sample throughput. The RIA is more sensitive than the EIA (10 μg/L vs. 35 μg/L). Both systems have excellent precision (X=86 μg/L, C.V.sub(RIA)=C.V.sub(EIA)=4.6 percent). Both the EIA and RIA demonstrate good accuracy with recovery of between 97-98 percent of added thyroxine. The FIA has an apparent sensitiviity between that of the RIA and EIA (25 μg/L), but a precision consistently lower than the other two systems (C.V. =7.4 percent, X=86 μg/L). Patients' results by RIA compared well with those from EIA (r=0.91,P 0.05). Although not fully automated, the EIA performed on the Abbott ABA-100 analyzer has a sample throughput equal to the automated RIA system (Micromedic, Concept 4)

  13. Multi-site, multi-country evaluation of analytical and operational performance of a low-mid volume chemiluminescent immunoassay analyzer.

    Science.gov (United States)

    De Keijzer, M H; Perkins, S; Motta, V; Morelli, D; Cristol, J P; Dupuy, A M; Hong, Y; Watanabe, S; Waerdt, C; Grunewald, R W

    2009-01-01

    A new automated immunoassay low-mid volume (beta-hCG, BNP, and CK-MB) and the time required to complete workloads of 50 and 100 tests with a mixture of 75% routine tests and 25% stat tests was also evaluated. Total precision was typically market and in use for an existing high volume immunoassay system. Stat turn around times were consistent with the fixed analytical time of 15.6 minutes and met the expectations of the laboratories. Measured test throughput ranged from 47 - 54 tests per hour and demonstrated that the analyzer was fit for the intended purpose of supporting a laboratory that performs suitable for use.

  14. Comparison between Amnisure Placental Alpha Microglobulin-1 Rapid Immunoassay and Standard Diagnostic Methods for Detection of Rupture of Membranes

    Directory of Open Access Journals (Sweden)

    Beng Kwang Ng

    2013-01-01

    Full Text Available Objective. To determine the diagnostic accuracy of placental alpha microglobulin-1 assay and standard diagnostic methods for detecting rupture of membrane. Study Design. Prospective diagnostic study, between June 2011 to November 2011 at a tertiary centre. Initial evaluation included both the standard diagnostic methods for rupture of membranes and placental alpha microglobulin-1 immunoassay. The actual rupture of membranes was diagnosed on review of the medical records after delivery (absence of membrane or a positive pad chart. Main Outcome Measures. Placental alpha microglobulin-1 immunoassay and standard diagnostic methods for diagnosis of rupture of membrane. Results. A total of 211 patients were recruited. At initial presentation, 187 patients (88.6% had ruptured membranes, while 24 patients (11.4% had intact membranes. Placental alpha microglobulin-1 immunoassay confirmed rupture of membranes at initial presentation with a sensitivity of 95.7% (179 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (179 of 179, and negative predictive value of 75.0% (24 of 32. By comparison, the conventional standard diagnostic methods had a sensitivity of 78.1% (146 of 187, specificity of 100% (24 of 24, positive predictive value of 100% (146 of 146, and negative predictive value of 36.9% (24 of 65 in diagnosing rupture of membrane. Conclusion. Placental alpha-microglobulin-1 immunoassay is a rapid and accurate method for confirming the diagnosis of rupture of membrane. It was superior to conventional standard diagnostic methods (pooling, nitrazine, and ferning, the nitrazine test alone or fern test alone.

  15. The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays.

    Science.gov (United States)

    Zhan, Li; Guo, Shuang-Zhuang; Song, Fayi; Gong, Yan; Xu, Feng; Boulware, David R; McAlpine, Michael C; Chan, Warren C W; Bischof, John C

    2017-12-13

    Rapid, simple, and cost-effective diagnostics are needed to improve healthcare at the point of care (POC). However, the most widely used POC diagnostic, the lateral flow immunoassay (LFA), is ∼1000-times less sensitive and has a smaller analytical range than laboratory tests, requiring a confirmatory test to establish truly negative results. Here, a rational and systematic strategy is used to design the LFA contrast label (i.e., gold nanoparticles) to improve the analytical sensitivity, analytical detection range, and antigen quantification of LFAs. Specifically, we discovered that the size (30, 60, or 100 nm) of the gold nanoparticles is a main contributor to the LFA analytical performance through both the degree of receptor interaction and the ultimate visual or thermal contrast signals. Using the optimal LFA design, we demonstrated the ability to improve the analytical sensitivity by 256-fold and expand the analytical detection range from 3 log 10 to 6 log 10 for diagnosing patients with inflammatory conditions by measuring C-reactive protein. This work demonstrates that, with appropriate design of the contrast label, a simple and commonly used diagnostic technology can compete with more expensive state-of-the-art laboratory tests.

  16. Rapid and Highly Sensitive Non-Competitive Immunoassay for Specific Detection of Nodularin

    Directory of Open Access Journals (Sweden)

    Sultana Akter

    2017-09-01

    Full Text Available Nodularin (NOD is a cyclic penta-peptide hepatotoxin mainly produced by Nodularia spumigena, reported from the brackish water bodies of various parts of the world. It can accumulate in the food chain and, for safety reasons, levels of NOD not only in water bodies but also in food matrices are of interest. Here, we report on a non-competitive immunoassay for the specific detection of NOD. A phage display technique was utilized to interrogate a synthetic antibody phage library for binders recognizing NOD bound to an anti-ADDA (3-Amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4(E,6(E-dienoic acid monoclonal antibody (Mab. One of the obtained immunocomplex binders, designated SA32C11, showed very high specificity towards nodularin-R (NOD-R over to the tested 10 different microcystins (microcystin-LR, -dmLR, -RR, -dmRR, -YR, -LY, -LF, -LW, -LA, -WR. It was expressed in Escherichia coli as a single chain antibody fragment (scFv fusion protein and used to establish a time-resolved fluorometry-based assay in combination with the anti-ADDA Mab. The detection limit (blank + 3SD of the immunoassay, with a total assay time of 1 h 10 min, is 0.03 µg/L of NOD-R. This represents the most sensitive immunoassay method for the specific detection of NOD reported so far. The assay was tested for its performance to detect NOD using spiked (0.1 to 3 µg/L of NOD-R water samples including brackish sea and coastal water and the recovery ranged from 79 to 127%. Furthermore, a panel of environmental samples, including water from different sources, fish and other marine tissue specimens, were analyzed for NOD using the assay. The assay has potential as a rapid screening tool for the analysis of a large number of water samples for the presence of NOD. It can also find applications in the analysis of the bioaccumulation of NOD in marine organisms and in the food chain.

  17. Increasing of sensitivity of fluorescent immunoassay analysis of alpha-fetoprotein by means of plasmonical silver nanoparticles

    International Nuclear Information System (INIS)

    Vashchenko, S.V.; Min'ko, A.A.; Romanenko, A.A.; Gaponenko, S.V.; Kulakovich, O.S.

    2014-01-01

    A test system is proposed based on metal enhanced fluorescence to analyze low concentrations of alpha-fetoprotein (AFP), a tumor marker. Antigen-antibody reaction was performed on polystyrene plates coated with silver nanoparticles to increase sensitivity of fluorescent immunoassay and signal-to-noise ratio as compared to silver-free system. As compared to widely used ELISA technique and other immunoassay techniques the proposed approach is characterized by smaller probe volume, fast analysis and simplicity. The proposed test system uses layer-by-layer assembly approach, LED excitation and nanowatt photodetection set-up. The proposed test system offers AFP detection at concentrations used in clinical practice. Fluorescence enhancement for labeled AFP antibodies on a silver substrate was found to depend on antibodies concentration and was up to 6 times. (authors)

  18. Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals.

    Science.gov (United States)

    Akbas, Neval; Schryver, Patricia G; Algeciras-Schimnich, Alicia; Baumann, Nikola A; Block, Darci R; Budd, Jeffrey R; Gaston, S J Stephen; Klee, George G

    2014-11-01

    We evaluated the analytical performance of 24 immunoassays using the Beckman Coulter DxI 800 immunoassay systems at Mayo Clinic, Rochester, MN for trueness, precision, detection limits, linearity, and consistency (across instruments and reagent lots). Clinically oriented performance goals were defined using the following methods: trueness-published desirable accuracy limits, precision-published desirable biologic variation; detection limits - 0.1 percentile of patient test values, linearity - 50% of total error, and consistency-percentage test values crossing key decision points. Local data were collected for precision, linearity, and consistency. Data were provided by Beckman Coulter, Inc. for trueness and detection limits. All evaluated assays except total thyroxine were within the proposed goals for trueness. Most of the assays met the proposed goals for precision (86% of intra-assay results and 75% of inter-assay results). Five assays had more than 15% of the test results below the minimum detection limits. Carcinoembryonic antigen, total thyroxine and free triiodothyronine exceeded the proposed goals of ±6.3%, ±5% and ±5.7% for dilution linearity. All evaluated assays were within the proposed goals for instrument consistency. Lot-to-lot consistency results for cortisol, ferritin and total thyroxine exceeded the proposed goals of 3.3%, 11.4% and 7% at one medical decision level, while vitamin B12 exceeded the proposed goals of 5.2% and 3.8% at two decision levels. The Beckman Coulter DxI 800 immunoassay system meets most of these proposed goals, even though these clinically focused performance goals represent relatively stringent limits. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. Functionalization of SU-8 Photoresist Surfaces with IgG Proteins

    DEFF Research Database (Denmark)

    Blagoi, Gabriela; Keller, Stephan Urs; Johansson, Alicia

    2008-01-01

    immunoassays were employed to characterize the binding efficiency of model proteins to bare SU-8 surface, SU-8 treated with cerium ammonium nitrate (CAN) etchant and CAN treated surfaces modified by aminosilanization. The highest binding capacity of antibodies was observed on bare SU-8. This explains why bare...... SU-8 in a functional fluorescent sandwich immunoassay detecting C-reactive protein (CRP) gave twice as high signal as compared with the other two surfaces. Immunoassays performed on bare SU-8 and CAN treated SU-8 resulted in detection limits of CRP of 30 and 80 ng/ml respectively which is sufficient...... for detecting CRP in clinical samples, where concentrations of 3–10 μg/ml are normal for healthy individuals. In conclusion, bare SU-8 and etched SU-8 can be modified with antibodies by a simple adsorption procedure which simplifies building lab-on-a-chip systems in SU-8. Additionally, we report the fabrication...

  20. Use of molecular binding pair technology for definitive product marking and identification

    Science.gov (United States)

    Rittenburg, James H.

    1998-04-01

    Counterfeiting and diversion of brand name products is a significant worldwide problem. Loss of revenue to the manufacturers is obviously important, however erosion of consumer confidence, and liability for adverse health effects or performance caused by poor quality product can be of even greater significance. Biocode has developed a novel approach to product marking and identification that utilizes molecular binding pair technologies such as immunoassay. The sensitivity, specificity, and ease of use of immunoassay provides a powerful method for detecting trace levels of intentionally added chemical markers. Using the diversity of the immune response, Biocode has developed a library of binding molecules and highly sensitive immunoassay systems for detection and measurement of a variety of chemical markers. The markers have been selected based on their stability and compatibility within various types of products. For food, beverage, and pharmaceutical applications, common and naturally occurring food ingredients and pharmaceutical excipients provide markers which are safe, readily available, and already approved for use. For other applications such as fuel and lubricant marking. Solubility and chemical stability of the markers are a major consideration. In addition to incorporating markers directly into products, Biocode has also developed invisible inks that can be printed onto the surface of products, packaging, or labels. The trace levels of marker that is printed onto the surface of a product or package can only be revealed by using the complementary binding pair that has been developed by Biocode. This technology provides for simple field tests and very high level of security as it is virtually impossible to copy.

  1. Rapid, Automated, and Specific Immunoassay to Directly Measure Matrix Metalloproteinase-9–Tissue Inhibitor of Metalloproteinase-1 Interactions in Human Plasma Using AlphaLISA Technology: A New Alternative to Classical ELISA

    Directory of Open Access Journals (Sweden)

    Helena Pulido-Olmo

    2017-07-01

    Full Text Available The protocol describes a novel, rapid, and no-wash one-step immunoassay for highly sensitive and direct detection of the complexes between matrix metalloproteinases (MMPs and their tissue inhibitor of metalloproteinases (TIMPs based on AlphaLISA® technology. We describe two procedures: (i one approach is used to analyze MMP-9–TIMP-1 interactions using recombinant human MMP-9 with its corresponding recombinant human TIMP-1 inhibitor and (ii the second approach is used to analyze native or endogenous MMP-9–TIMP-1 protein interactions in samples of human plasma. Evaluating native MMP-9–TIMP-1 complexes using this approach avoids the use of indirect calculations of the MMP-9/TIMP-1 ratio for which independent MMP-9 and TIMP-1 quantifications by two conventional ELISAs are needed. The MMP-9–TIMP-1 AlphaLISA® assay is quick, highly simplified, and cost-effective and can be completed in less than 3 h. Moreover, the assay has great potential for use in basic and preclinical research as it allows direct determination of native MMP-9–TIMP-1 complexes in circulating blood as biofluid.

  2. Detection of hidden hazelnut protein in food by IgY-based indirect competitive enzyme-immunoassay

    NARCIS (Netherlands)

    Baumgartner, S.; Bremer, M.G.E.G.; Kemmers - Voncken, A.E.M.; Smits, N.G.E.; Haasnoot, W.; Banks, J.; Reece, P.; Danks, C.; Tomkies, V.; Immer, U.; Schmitt, K.; Krska, R.

    2004-01-01

    The development of an indirect competitive enzyme-immunoassay for the detection of hidden hazelnut protein in complex food matrices is described. A sensitive and selective polyclonal antibody was raised by immunisation of laying hens with protein extracts from roasted hazelnuts. In contrast to

  3. Ervaringen met een solid phase enzyme immunoassay voor het aantonen van gonorroe bij promiscue vrouwen

    NARCIS (Netherlands)

    Ulsen; J.van*; Michel; M.F.*; Strik; R.van*; Joost; T.H.van*; Stolz; E.*; Eijk; R.V.W.van

    1985-01-01

    De Gonozyme test (Abbott Laboratories), een nieuwe enzyme immunoassay (EIA) voor het aantonen van Neisseria gonorrhoeae werd geevalueerd in een grote groep promiscue vrouwen. Als de EIA werd uitgevoerd met materiaal afkomstig van de cervix, bedroeg de prevalentie van gonorroe 8,2%. Vergeleken

  4. Nanobody Technology for Mycotoxin Detection in the Field of Food Safety: Current Status and Prospects.

    Science.gov (United States)

    He, Ting; Zhu, Jiang; Nie, Yao; Hu, Rui; Wang, Ting; Li, Peiwu; Zhang, Qi; Yang, Yunhuang

    2018-04-29

    Mycotoxins, which are toxic, carcinogenic, and/or teratogenic, have posed a threat to food safety and public health. Sensitive and effective determination technologies for mycotoxin surveillance are required. Immunoassays have been regarded as useful supplements to chromatographic techniques. However, conventional antibodies involved in immunoassays are difficult to be expressed recombinantly and are susceptible to harsh environments. Nanobodies (or VHH antibodies) are antigen-binding sites of the heavy-chain antibodies produced from Camelidae. They are found to be expressed easily in prokaryotic or eukaryotic expression systems, more robust in extreme conditions, and facile to be used as surrogates for artificial antigens. These properties make them the promising and environmentally friendly immunoreagents in the next generation of immunoassays. This review briefly describes the latest developments in the area of nanobodies used in mycotoxin detection. Moreover, by integrating the introduction of the principle of nanobodies production and the critical assessment of their performance, this paper also proposes the prospect of nanobodies in the field of food safety in the foreseeable future.

  5. Europium(III) chelate-dyed nanoparticles as donors in a homogeneous proximity-based immunoassay for estradiol

    International Nuclear Information System (INIS)

    Kokko, Leena; Sandberg, Kaisa; Loevgren, Timo; Soukka, Tero

    2004-01-01

    Nanoparticles containing thousands of fluorescent europium(III) chelates have a very high specific activity compared to traditional lanthanide chelate labels. It can be assumed that if these particles are used in a homogeneous assay as donors, multiple chelates can excite a single acceptor in turns and the energy transfer to the acceptor is increased. The principle was employed in an immunoassay using luminescent resonance energy transfer from a long lifetime europium(III) chelate-dyed nanoparticle to a short lifetime, near-infrared fluorescent molecule. Due to energy transfer fluorescence lifetime of the sensitised emission was prolonged and fluorescence could be measured using a time-resolved detection. A competitive homogeneous immunoassay for estradiol was created using 92 nm europium(III) chelate-dyed nanoparticle coated with 17β-estradiol specific recombinant antibody Fab fragments as a donor and estradiol conjugated with near-infrared dye AlexaFluor 680 as an acceptor. The density of Fab fragments on the surface of the particle influenced the sensitivity of the immunoassay. The optimal Fab density was reached when the entire surface of the particle participated in the energy transfer, but the areas where the energy was transferred to a single acceptor, did not overlap. We were able to detect estradiol concentrations down to 70 pmol l -1 (3xSD of a standard containing 0 nmol l -1 of E2) using a 96-well platform. In this study we demonstrated that nanoparticles containing lanthanide chelates could be used as efficient donors in homogeneous assays

  6. Positive predictive value of the immunoassay for Clostridium difficile toxin A and B detection at a private hospital.

    Science.gov (United States)

    Pérez-Topete, S E; Miranda-Aquino, T; Hernández-Portales, J A

    Clostridium difficile (C. difficile) is a Gram-positive bacillus that is a common cause of diarrhea in the hospital environment, with a documented incidence of up to 10%. There are different methods to detect it, but a widely used test in our environment is the immunoassay for toxins A and B. The aim of our study was to 1) estimate the positive predictive value of the immunoassay for the detection of the C. difficile toxins A and B, 2) to establish the incidence of C. difficile-associated diarrhea in the hospital, and 3) to know the most common associated factors. A diagnostic test accuracy study was conducted within the time frame of January 2010 to August 2013 at the Hospital Christus Muguerza® Alta Especialidad on patients with symptoms suggestive of C. difficile-associated diarrhea that had a positive immunoassay test and confirmation of C. difficile through colon biopsy and stool culture. The immunoassay for toxins A and B was performed in 360 patients. Fifty-five of the cases had positive results, 35 of which showed the presence of C. difficile. Incidence was 10.2% and the positive predictive value of the test for C. difficile toxins A and B was 0.64 (95% CI, 0.51-0.76). Previous antibiotic therapy (n=29) and proton pump inhibitor use (n=19) were the most common associated factors. C. difficile incidence in our environment is similar to that found in the literature reviewed, but the positive predictive value of the test for toxin A and B detection was low. Copyright © 2016 Asociación Mexicana de Gastroenterología. Publicado por Masson Doyma México S.A. All rights reserved.

  7. A New Framework for Evaluating the Functional Capabilities of Intra-Enterprise Application Integration Technologies

    Directory of Open Access Journals (Sweden)

    Hossein Moradi

    2010-10-01

    Full Text Available Enterprise Application Integration (EAI technologies facilitate the sharing of information and business processes of interrelated information systems in order to achieve the target integrated systems. Different EAI solutions and technologies provide various capabilities which lead to the complexity of their evaluation process. To reduce this complexity, appropriate tools for evaluating the functional capabilities of EAI technologies are required. This paper proposes a new framework for evaluating the functional capabilities of EAI technologies, which simplify the process of evaluating the functional capabilities of intra-enterprise integration technologies and solutions.The proposed framework for evaluating the EAI technologies was enhanced using the structural and conceptual aspects of previous frameworks. It offers a new schema for which various EAI technologies are categorized in different classes and are evaluated based on their supporting level for functional integration capabilities’ criteria.The new framework offers two lists containing integration technologies and their associated classifications, and functional capabilities of integration technologies. The proposed framework is a novel one which can be used by information system experts for evaluation and comparison purposes of various integration technologies.

  8. On-Chip Immunoassay for Determination of Urinary Albumin

    Directory of Open Access Journals (Sweden)

    Adisorn Tuantranont

    2009-12-01

    Full Text Available An immunoassay performed on a portable microfluidic device was evaluated for the determination of urinary albumin. An increase in absorbance at 500 nm resulting from immunoagglutination was monitored directly on the poly(dimethylsiloxane (PDMS microchip using a portable miniature fibre-optic spectrometer. A calibration curve was linear up to 10 mg L–1 (r2 = 0.993, with a detection limit of 0.81 mg L–1 (S/N = 3. The proposed system showed good precision, with relative standard deviations (RSDs of 5.1%, when evaluated with 10 mg L–1 albumin (n = 10. Determination of urinary albumin with the proposed system gave results highly similar to those determined by the conventional spectrophotometric method using immunoturbidimetric detection (r2 = 0.995; n = 15.

  9. Rapid screening of aflatoxin B1 in beer by fluorescence polarization immunoassay.

    Science.gov (United States)

    Beloglazova, N V; Eremin, S A

    2015-09-01

    This manuscript describes the development of a sensitive, fast and easily-performed fluorescence polarization immunoassay (FPIA) for the mycotoxin aflatoxin B1 (AFB1) in various beer samples, both lager and dark. The highest sensitivity was determined for six poly- and monoclonal antibodies selective towards aflatoxins. The sample pretreatment design was emphasized since beer samples are characterized by extremely diverse matrices. Herein, the choice of sorbent for effective removal of matrix interferences prior to analysis was crucial. The samples were diluted with a borate buffer solution containing 1% PEG 6000 and passed through the clean-up column packed with NH2-derivated silica. This sample pretreatment technique was perfectly suitable for the FPIA of lager beer samples, but for dark beer and ale it did not suffice. An artificial matrix was constructed to plot a calibration curve and quantify the results of the latter samples. The developed immunoassay was characterized by a limit of detection of 1 ng mL(-1). Apparent recovery values of 89-114% for lager and 80-125% for dark beer were established. The FPIA data for AFB1 was characterized by elevated linear regression coefficients, 0.9953 for spiked lager and 0.9895 for dark beer samples respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Multiplex immunoassays for quantification of cytokines, growth factors, and other proteins in stem cell communication

    Czech Academy of Sciences Publication Activity Database

    Valeková, Ivona; Kupcová Skalníková, Helena; Jarkovská, Karla; Motlík, Jan; Kovářová, Hana

    -, č. 1212 (2015), s. 39-63 ISSN 1940 -6029 R&D Projects: GA MŠk ED2.1.00/03.0124; GA TA ČR(CZ) TA01011466 Institutional support: RVO:67985904 Keywords : multiplex immunoassays * antibody microarray * luminex xMAP Subject RIV: EB - Genetics ; Molecular Biology

  11. Structural basis for the high specificity of a Trypanosoma congolense immunoassay targeting glycosomal aldolase.

    Directory of Open Access Journals (Sweden)

    Joar Pinto

    2017-09-01

    Full Text Available Animal African trypanosomosis (AAT is a neglected tropical disease which imposes a heavy burden on the livestock industry in Sub-Saharan Africa. Its causative agents are Trypanosoma parasites, with T. congolense and T. vivax being responsible for the majority of the cases. Recently, we identified a Nanobody (Nb474 that was employed to develop a homologous sandwich ELISA targeting T. congolense fructose-1,6-bisphosphate aldolase (TcoALD. Despite the high sequence identity between trypanosomatid aldolases, the Nb474-based immunoassay is highly specific for T. congolense detection. The results presented in this paper yield insights into the molecular principles underlying the assay's high specificity.The structure of the Nb474-TcoALD complex was determined via X-ray crystallography. Together with analytical gel filtration, the structure reveals that a single TcoALD tetramer contains four binding sites for Nb474. Through a comparison with the crystal structures of two other trypanosomatid aldolases, TcoALD residues Ala77 and Leu106 were identified as hot spots for specificity. Via ELISA and surface plasmon resonance (SPR, we demonstrate that mutation of these residues does not abolish TcoALD recognition by Nb474, but does lead to a lack of detection in the Nb474-based homologous sandwich immunoassay.The results show that the high specificity of the Nb474-based immunoassay is not determined by the initial recognition event between Nb474 and TcoALD, but rather by its homologous sandwich design. This (i provides insights into the optimal set-up of the assay, (ii may be of great significance for field applications as it could explain the potential detection escape of certain T. congolense strains, and (iii may be of general interest to those developing similar assays.

  12. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    Science.gov (United States)

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  13. Myeloma-Derived Light Chain Paired with a Diagnostic Monoclonal Antibody Hinders Immunoassay Performance.

    Science.gov (United States)

    Tu, Bailin; Tieman, Bryan; Moore, Jeffrey; Pan, You; Muerhoff, A Scott

    2017-06-01

    Monoclonal antibodies are widely used as the capture and detection reagents in diagnostic immunoassays. In the past, myeloma fusion partners expressing endogenous heavy and/or light chains were often used to generate hybridoma cell lines. As a result, mixed populations of antibodies were produced that can cause inaccurate test results, poor antibody stability, and significant lot-to-lot variability. We describe one such scenario where the P3U1 (P3X63Ag8U.1) myeloma fusion partner was used in the generation of a hybridoma producing protein induced vitamin K absence/antagonist-II (PIVKA II) antibody. The hybridoma produces three subpopulations of immunoglobulin as determined by ion exchange (IEx) chromatography that exhibit varying degrees of immunoreactivity (0%, 50%, or 100%) to the target antigen as determined by Surface Plasmon Resonance. To produce an antibody with the highest possible sensitivity and specificity, the antigen-specific heavy and light chain variable domains (VH and VL) were cloned from the hybridoma and tethered to murine IgG1 and kappa scaffolds. The resulting recombinant antibody was expressed in Chinese hamster ovary cells and is compatible for use in a diagnostic immunoassay.

  14. [Membrane-filtration immunoassay: reagents, methods and the diagnostic and technical means for detection].

    Science.gov (United States)

    Khramov, E N; Osin, N S; Pomelova, V G; Vikha, I V; Bychenkova, T A; Smirnova, V G; Grakina, G I; Kas'ianova, T A

    1999-01-01

    The comprehensive development of dot-EIA made at the State Research Institute of Biological Instrument-Making Industry has provided devices KIMF-02 and KIMF-03), a base of chemical reagents, immunoassays, test systems for detection of a wide range of causative agents of viral and bacterial infections, that of serodiagnosis of their related diseases. The KIMF-02 kit has undergone engineering and medical tests and recommended for the Ministry of Health of the Russian Federation to produce them in stock. The kit includes all required for analysis even in an ill-equipped laboratory, a set of attached agents ensures a valid visual recording of results. The developed procedures and test systems allow the immunoassay to be as sensitive as TIFA; however, they are laborious and much simpler in design. The simple and rapid procedures of dot-EIA are recommended for incorporation into the a package of laboratory methods for verification of the accumulation of virus-specific antigens in various biological substrata, environmental samples, for control of the activity of antigens and antibodies used in serological tests, for detection of specific antigens in the clinical samples, and for serodiagnosis of infections.

  15. Thermophilic Campylobacter spp. in turkey samples: evaluation of two automated enzyme immunoassays and conventional microbiological techniques

    DEFF Research Database (Denmark)

    Borck, Birgitte; Stryhn, H.; Ersboll, A.K.

    2002-01-01

    Aims: To determine the sensitivity and specificity of two automated enzyme immunoassays (EIA), EiaFoss and Minividas, and a conventional microbiological culture technique for detecting thermophilic Campylobacter spp. in turkey samples. Methods and Results: A total of 286 samples (faecal, meat...

  16. Competitive enzyme immunoassay for human chorionic somatomammotropin using the avidin-biotin system

    International Nuclear Information System (INIS)

    Rappuoli, R.; Leoncini, P.; Tarli, P.; Neri, P.

    1981-01-01

    Human chorionic somatomammotropin (HCS) is determined by an enzyme immunoassay where HCS competes with biotin-labeled HCS for insolubilized anti-HCS antibodies. Enzyme-labeled avidin is then used to reveal the amount of bound HCS. The system proves to be sensitive (1 ng/ml of HCS can be detected) and results agree with radioimmunoassay determinations (correlation coefficient = 0.979). Kinetics of the avidin-biotin reaction and coating of polystyrene wells are also investigated

  17. The field application of an immunoassay-based test for petroleum fuels contamination in groundwater

    International Nuclear Information System (INIS)

    Carter, K.R.

    1994-01-01

    The recent development of low-cost, rapid field analytical tests for petroleum fuels based on immunoassay technology has provided an on-site tool for the cost-effective, accurate assessment of groundwater contamination. The method allows for rapid, direct measurement of contaminant concentration. The method has been used for a variety of applications including surface water runoff testing and groundwater monitoring well siting. The PETRO RISc Water Test can be used to substantially reduce the cost of monitoring well installation. Current, monitoring wells are placed based on knowledge of the location of the source of contamination, the size of the release, the time elapsed since the release began, and the hydrogeology of the site. While the location of the source is generally known with some precision, the hydrogeology of the site and the timing of the release rarely are. This results in the need for an ''educated guess'' regarding the drilling location for monitoring wells that are installed to provide long term feedback on groundwater contamination. The tests have the greatest sensitivity to aliphatic compounds in the range of six to ten carbons and aromatic compounds such as toluene, xylene, and naphthalene

  18. Concordance Between Different Amyloid Immunoassays and Visual Amyloid Positron Emission Tomographic Assessment.

    Science.gov (United States)

    Janelidze, Shorena; Pannee, Josef; Mikulskis, Alvydas; Chiao, Ping; Zetterberg, Henrik; Blennow, Kaj; Hansson, Oskar

    2017-12-01

    Visual assessment of amyloid positron emission tomographic (PET) images has been approved by regulatory authorities for clinical use. Several immunoassays have been developed to measure β-amyloid (Aβ) 42 in cerebrospinal fluid (CSF). The agreement between CSF Aβ42 measures from different immunoassays and visual PET readings may influence the use of CSF biomarkers and/or amyloid PET assessment in clinical practice and trials. To determine the concordance between CSF Aβ42 levels measured using 5 different immunoassays and visual amyloid PET analysis. The study included 262 patients with mild cognitive impairment or subjective cognitive decline from the Swedish BioFINDER (Biomarkers for Identifying Neurodegenerative Disorders Early and Reliably) cohort (recruited from September 1, 2010, through December 31, 2014) who had undergone flutemetamol F 18 ([18F]flutemetamol)-labeled PET. Levels of CSF Aβ42 were analyzed using the classic INNOTEST and the newer modified INNOTEST, fully automated Lumipulse (FL), EUROIMMUN (EI), and Meso Scale Discovery (MSD) assays. Concentrations of CSF Aβ were assessed using an antibody-independent mass spectrometry-based reference measurement procedure. The concordance of CSF Aβ42 levels and Aβ42:Aβ40 and Aβ42:tau ratios with visual [18F]flutemetamol PET status. Of 262 participants (mean [SD] age, 70.9 [5.5] years), 108 were women (41.2%) and 154 were men (58.8%). The mass spectrometry-derived Aβ42 values showed higher correlations with the modified Aβ42-INNOTEST (r = 0.97), Aβ42-FL (r = 0.93), Aβ42-EI (r = 0.93), and Aβ42-MSD (r = 0.95) assays compared with the classic Aβ42-INNOTEST assay (r = 0.88; P ≤ .01). The signal in the classic Aβ42-INNOTEST assay was partly quenched by recombinant Aβ1-40 peptide. However, the classic Aβ42-INNOTEST assay showed better concordance with visual [18F]flutemetamol PET status (area under the receiver operating characteristic curve [AUC], 0.92) compared with the

  19. Electrochemical Sandwich Immunoassay for the Ultrasensitive Detection of Human MUC1 Cancer Biomarker

    Directory of Open Access Journals (Sweden)

    Zahra Taleat

    2013-01-01

    Full Text Available A new electrochemical sandwich immunoassay for the ultrasensitive detection of human MUC1 cancer biomarker using protein G-functionalized magnetic beads (MBs and graphite-based screen-printed electrodes (SPEs was developed. Magnetic beads were employed as the platforms for the immobilization and immunoreaction process. A pair of primary and secondary antibodies was used to capture the MUC1 protein. After labeling with a third antibody conjugated with horseradish peroxidase (HRP, the resulting conjugate was trapped at the surface of the graphite-based SPEs and MUC1 determination was carried out by differential pulse voltammetry (DPV at 0.4 V upon H2O2 addition using acetaminophen (APAP as the redox mediator. A linear relationship was obtained for the detection of human MUC1 over a range of 0–25 ppb with the lowest detection limit of 1.34 ppb when HRP was applied as a label. Preliminary experiments were performed using disposable electrochemical sensors in order to optimize some parameters (i.e., incubation times, concentrations, and blocking agent.

  20. Development of an ultrasensitive immunoassay for detecting tartrazine.

    Science.gov (United States)

    Li, Zhuokun; Song, Shanshan; Xu, Liguang; Kuang, Hua; Guo, Shidong; Xu, Chuanlai

    2013-06-25

    We have developed an ultrasensitive indirect competitive enzyme-linked immunosorbent assay for the determination of tartrazine. Two carboxylated analogues of tartrazine with different spacer lengths, and one derivative from commercial tartrazine after a little chemical modification, were synthesized as haptens in order to produce antibodies specific to tartrazine. The effect of sulfonic acid groups on the hapten structure of tartrazine was also studied carefully for the first time. A most specific monoclonal antibody against tartrazine was created and exhibited an IC50 value of 0.105 ng/mL and a limit of detection of 0.014 ng/mL, with no cross-reactivity to other structurally-related pigments. The established immunoassay was applied to the determination of tartrazine in fortified samples of orange juice and in real positive samples of carbonated beverages.

  1. Sequential injection chemiluminescence immunoassay for nonionic surfactants by using magnetic microbeads

    International Nuclear Information System (INIS)

    Zhang Ruiq; Nakajima, Hizuru; Soh, Nobuaki; Nakano, Koji; Masadome, Takashi; Nagata, Kazumi; Sakamoto, Kazuhira; Imato, Toshihiko

    2007-01-01

    A rapid and sensitive immunoassay based on a sequential injection analysis (SIA) using magnetic microbeads for the determination of alkylphenol polyethoxylates (APnEOs) is described. An SIA system was constructed from a syringe pump, a switching valve, a flow-through type immunoreaction cell equipped with a photon counting unit and a neodymium magnet. Magnetic beads, to which an anti-APnEOs monoclonal antibody was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of the magnetic beads in and from the immunoreaction cell were controlled by means of a neodymium magnet and adjusting the flow of a carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an anti-APnEOs monoclonal antibody immobilized on the magnetic beads with a sample APnEOs and a horseradish peroxidase (HRP)-labeled APnEOs in the same sample solution, and was based on the subsequent chemiluminscence reaction of HRP on the magnetic microbeads with a luminol solution containing hydrogen peroxide and p-iodophenol. The anti-APnEOs antibody was immobilized on the magnetic microbeads by coupling the antibody with the magnetic beads after activation of a carboxylate moiety on the surface of the magnetic beads that had been coated with a polylactic acid film. The antibody immobilized magnetic beads were introduced in the immunoreaction cell and trapped in it by the neodymium magnet, which was equipped beneath the immunoreaction cell. An APnEOs sample solution containing the HRP-labeled APnEOs at a constant concentration, and a luminol solution containing hydrogen peroxide and p-iodophenol were sequentially introduced into the immunoreaction cell, according to an SIA programmed sequence. Chemiluminescence emission was monitored by means of a photon counting unit located at the upper side of the immunoreaction cell by collecting the emitted light with a lens. A typical sigmoidal calibration curve was obtained, when the logarithm

  2. Liquid Chromatography-Tandem Mass Spectrometry: An Emerging Technology in the Toxicology Laboratory.

    Science.gov (United States)

    Zhang, Yan Victoria; Wei, Bin; Zhu, Yu; Zhang, Yanhua; Bluth, Martin H

    2016-12-01

    In the last decade, liquid chromatography-tandem mass spectrometry (LC-MS/MS) has seen enormous growth in routine toxicology laboratories. LC-MS/MS offers significant advantages over other traditional testing, such as immunoassay and gas chromatography-mass spectrometry methodologies. Major strengths of LC-MS/MS include improvement in specificity, flexibility, and sample throughput when compared with other technologies. Here, the basic principles of LC-MS/MS technology are reviewed, followed by advantages and disadvantages of this technology compared with other traditional techniques. In addition, toxicology applications of LC-MS/MS for simultaneous detection of large panels of analytes are presented. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. A sulfhydryl-reactive ruthenium (II complex and its conjugation to protein G as a universal reagent for fluorescent immunoassays.

    Directory of Open Access Journals (Sweden)

    Jing-Tang Lin

    Full Text Available To develop a fluorescent ruthenium complex for biosensing, we synthesized a novel sulfhydryl-reactive compound, 4-bromophenanthroline bis-2,2'-dipyridine Ruthenium bis (hexafluorophosphate. The synthesized Ru(II complex was crosslinked with thiol-modified protein G to form a universal reagent for fluorescent immunoassays. The resulting Ru(II-protein G conjugates were identified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE. The emission peak wavelength of the Ru(II-protein G conjugate was 602 nm at the excitation of 452 nm which is similar to the spectra of the Ru(II complex, indicating that Ru(II-protein G conjugates still remain the same fluorescence after conjugation. To test the usefulness of the conjugate for biosensing, immunoglobulin G (IgG binding assay was conducted. The result showed that Ru(II-protein G conjugates were capable of binding IgG and the more cross-linkers to modify protein G, the higher conjugation efficiency. To demonstrate the feasibility of Ru(II-protein G conjugates for fluorescent immunoassays, the detection of recombinant histidine-tagged protein using the conjugates and anti-histidine antibody was developed. The results showed that the histidine-tagged protein was successfully detected with dose-response, indicating that Ru(II-protein G conjugate is a useful universal fluorescent reagent for quantitative immunoassays.

  4. Enzyme immunoassay of oestrogen receptors in needle biopsies from human liver

    DEFF Research Database (Denmark)

    Becker, U; Andersen, J; Poulsen, H S

    1991-01-01

    For quantitative assessments of sex hormone receptors in liver tissue, ligand binding assays are inconvenient, as they require large biopsies (0.5-1.0 g). The present study shows that it is possible to measure oestrogen receptors (ER) quantitatively in needle biopsy specimens as small as 10 mg...... by modifications of a commercial enzyme immunoassay employing monoclonal antibodies. Sucrose gradient centrifugation and the dextran charcoal method served as reference methods. A consecutive series of needle biopsies from patients suspected of liver disease were investigated. The biopsies (n = 37) had a median...

  5. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer.

    Science.gov (United States)

    Fu, Xiaoling; Liu, Yangyang; Qiu, Ruiyun; Foda, Mohamed F; Zhang, Yong; Wang, Tao; Li, Jinshan

    2018-03-01

    The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA) was presented for the clinical determination and analysis of human epididymis protein 4 (HE4) in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0-1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA), with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum.

  6. The Use of Recombinant Hemagglutinine Protein of Rinderpest Virus in Enzyme Immunoassay

    OpenAIRE

    BULUT, Hakan; BOLAT, Yusuf

    2003-01-01

    In this study, Rinderpest virus (RPV) recombinant hemagglutinine protein (rH) fused with protein A region of Staphylococcus aureus was expressed in Escherichia coli and purified by IgG affinity chromatography. rH protein was also used to establish enzyme immunoassay. Therefore, to prevent IgG binding to the protein A the wells coated with the rH proteins were blocked by human serum. Afterwards, RPV antigens were added to the wells to evaluate this assay. To this end, serum from mice immunized...

  7. Accuracy of immunoassay and mass spectrometry urinary free cortisol in the diagnosis of Cushing's syndrome.

    Science.gov (United States)

    Aranda, G; Careaga, M; Hanzu, F A; Patrascioiu, I; Ríos, P; Mora, M; Morales-Romero, B; Jiménez, W; Halperin, I; Casals, G

    2016-10-01

    Urinary free cortisol (UFC) determination by highly specific methods as mass spectrometry instead of commercially available antibody-based immunoassays is increasingly recommended. However, clinical comparisons of both analytical approaches in the screening of Cushing's syndrome (CS) are not available. The aim of this study was to evaluate the diagnostic value of mass spectrometry versus immunoassay measurements of 24 h-UFC in the screening of CS. Cross-sectional study of 33 histologically confirmed CS patients: 25 Cushing's disease, 5 adrenal CS and 3 ectopic CS; 92 non-CS patients; and 35 healthy controls. UFC by immunoassay (UFCxIA) and mass spectrometry (UFCxMS), urinary free cortisone (UFCo) and UFC:UFCo ratio were measured, together with creatinine-corrected values. Sensitivity, specificity, AUC and Landis and Koch concordance index were determined. AUC for UFCxIA and UFCxMS were 0.77 (CI 0.68-0.87) and 0.77 (CI 0.67-0.87) respectively, with a kappa coefficient 0.60 and strong Landis and Koch concordance index. The best calculated cutoff values were 359 nmol/24 h for UFCxIA (78 % sensitivity, 62 % specificity) and 258.1 nmol/24 h for UCFxMS (53 % sensitivity, 86 % specificity). The upper limit of UFCxIA and UCFxMS reference ranges were 344.7 and 169.5 nmol/24 h respectively. Sensitivity and specificity for CS diagnosis at these cutpoints were 84 and 56 % for UFCxIA and 81 and 54 % for UFCxMS. According to our data, both methods present a very similar diagnostic value. However, results suggest that lower cutoff points for mass spectrometry may be necessary in order to improve clinical sensitivity.

  8. Photoelectrochemical detection of enzymatically generated CdS nanoparticles: Application to development of immunoassay.

    Science.gov (United States)

    Barroso, Javier; Saa, Laura; Grinyte, Ruta; Pavlov, Valeri

    2016-03-15

    We report an innovative photoelectrochemical process (PEC) based on graphite electrode modified with electroactive polyvinylpyridine bearing osmium complex (Os-PVP). The system relies on the in situ enzymatic generation of CdS quantum dots (QDs). Alkaline phosphatase (ALP) catalyzes the hydrolisis of sodium thiophosphate (TP) to hydrogen sulfide (H2S) which in the presence Cd(2+) ions yields CdS semiconductor nanoparticles (SNPs). Irradiation of SNPs with the standard laboratory UV-illuminator (wavelength of 365 nm) results in photooxidation of 1-thioglycerol (TG) mediated by Os-PVP complex on the surface of graphite electrode at applied potential of 0.31 V vs. Ag/AgCl. A novel immunoassay based on specific enzyme linked immunosorbent assay (ELISA) combined with the PEC methodology was developed. Having selected the affinity interaction between bovine serum albumine (BSA) with anti-BSA antibody (AB) as a model system, we built the PEC immunoassay for AB. The new assay displays a linear range up to 20 ngmL(-1) and a detection limit (DL) of 2 ngmL(-1) (S/N=3) which is lower 5 times that of the traditional chromogenic ELISA test employing p-nitro-phenyl phosphate (pNPP). Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Plasma exchange to remove HIT antibodies: dissociation between enzyme-immunoassay and platelet activation test reactivities.

    Science.gov (United States)

    Warkentin, Theodore E; Sheppard, Jo-Ann I; Chu, F Victor; Kapoor, Anil; Crowther, Mark A; Gangji, Azim

    2015-01-01

    Repeated therapeutic plasma exchange (TPE) has been advocated to remove heparin-induced thrombocytopenia (HIT) IgG antibodies before cardiac/vascular surgery in patients who have serologically-confirmed acute or subacute HIT; for this situation, a negative platelet activation assay (eg, platelet serotonin-release assay [SRA]) has been recommended as the target serological end point to permit safe surgery. We compared reactivities in the SRA and an anti-PF4/heparin IgG-specific enzyme immunoassay (EIA), testing serial serum samples in a patient with recent (subacute) HIT who underwent serial TPE precardiac surgery, as well as for 15 other serially-diluted HIT sera. We observed that post-TPE/diluted HIT sera-when first testing SRA-negative-continue to test strongly positive by EIA-IgG. This dissociation between the platelet activation assay and a PF4-dependent immunoassay for HIT antibodies indicates that patients with subacute HIT undergoing repeated TPE before heparin reexposure should be tested by serial platelet activation assays even when their EIAs remain strongly positive. © 2015 by The American Society of Hematology.

  10. Development of an Ultrasensitive Immunoassay for Detecting Tartrazine

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-06-01

    Full Text Available We have developed an ultrasensitive indirect competitive enzyme-linked immunosorbent assay for the determination of tartrazine. Two carboxylated analogues of tartrazine with different spacer lengths, and one derivative from commercial tartrazine after a little chemical modification, were synthesized as haptens in order to produce antibodies specific to tartrazine. The effect of sulfonic acid groups on the hapten structure of tartrazine was also studied carefully for the first time. A most specific monoclonal antibody against tartrazine was created and exhibited an IC50 value of 0.105 ng/mL and a limit of detection of 0.014 ng/mL, with no cross-reactivity to other structurally-related pigments. The established immunoassay was applied to the determination of tartrazine in fortified samples of orange juice and in real positive samples of carbonated beverages.

  11. New antibody and immunoassay pretreatment strategy to screen polychlorinated biphenyls in Korean transformer oil.

    Science.gov (United States)

    Terakado, Shingo; Ohmura, Naoya; Park, Seok-Un; Lee, Seung-Min; Glass, Thomas R

    2013-01-01

    Development and modifications are described that expand the application of an immunoassay from the detection of Kanechlors (Japanese technical PCBs mixtures) to the detection of Aroclors (U. S. technical PCB mixtures, used in Korea) in contaminated Korean transformer oil. The first necessary modification was the development of a new antibody with a reactivity profile favorable for Aroclors. The second modification was the addition of a second column to the solid-phase extraction method to reduce assay interference caused by the Korean oil matrix. The matrix interference is suspected to be caused by the presence of synthetic oils (or similar materials) present as contaminants. The modified assay was validated by comparison to high-resolution gas chromatography/high-resolution mass spectrometry analysis, and was shown to be tolerant of up to 10% of several common synthetic insulating oils. Finally the screening performance of the modified assay was evaluated using 500 used transformer oil samples of Korean origin, and was shown to have good performance in terms of false positive and false negative rates. This report provides evidence for the first establishment of immunoassay screening for Aroclor based PCB contamination in Korean transformer oil.

  12. A redox-mediated chromogenic reaction and application in immunoassay.

    Science.gov (United States)

    Yu, Ru-Jia; Ma, Wei; Peng, Mao-Pan; Bai, Zhi-Shan; Long, Yi-Tao

    2016-08-31

    A novel redox-mediated chromogenic reaction was demonstrated based on the reaction between HAuCl4 and 2,2-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), which generate various color responses from red to green in the resulting solutions. Various redox substance could be used to mediate the reaction and trigger a distinct color response. We established a sensitive hydrogen peroxide colorimetric sensor based on the redox-mediated chromogenic reaction and depicted the application both in detection of enzyme and in an immunoassay. Combining the traditional chromogenic reagent with gold nanoparticles, our assay has the advantage in short response time (within three minutes), high sensitivity (10(-12) g mL(-1) for HBsAg) and stability. Copyright © 2016. Published by Elsevier B.V.

  13. Performance of immunoassay kits for site characterization and remediation

    International Nuclear Information System (INIS)

    Waters, L.C.; Palausky, A.; Counts, R.W.; Jenkins, R.A.

    1995-01-01

    The US Department of Energy (DOE) is supporting efforts to identify, validate and implement the use of effective, low-cost alternatives to currently used analytical methods for environmental management. As part of that program, we have evaluated the performances of a number of immunoassay (IA) kits with specificities for environmental contaminants of concern to the DOE. The studies were done in the laboratory using both spiked and field test samples. The analyte specificity and manufacturers of the kits evaluated were the following: mercury, BioNebraska; polychlorinated biphenyls (PCBs), EnSys and Millipore; petroleum fuel hydrocarbons, Millipore and Ohmicron; and polyaromatic hydrocarbons (PAHs), Ohmicron and Millipore. The kits were used in either a semiquantitative or quantitative format according to the preference of the manufacturers

  14. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots.

    Science.gov (United States)

    Chen, Rui; Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua; Xiong, Yonghua

    2016-12-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H 2 O 2 ) and H 2 O 2 -sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H 2 O 2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H 2 O 2 , as well as the incubation time between H 2 O 2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10 2  CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10 3  CFU/mL to 1.18 × 10 6  CFU/mL were in the range of 65.88%-105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Strip-based immunoassay for the simultaneous detection of the neonicotinoid insecticides imidacloprid and thiamethoxam in agricultural products

    Science.gov (United States)

    A semiquantitative strip immunoassay was developed for the rapid detection of imidacloprid and thiamethoxam in agricultural products using specific nanocolloidal gold-labeled monoclonal antibodies. The conjugates of imidacloprid-BSA and thiamethoxam-BSA and goat anti-mouse IgG were coated on the ni...

  16. Quantification of patient specific assay interference in different formats of enzyme linked immunoassays for therapeutic monoclonal antibodies

    NARCIS (Netherlands)

    Grebenchtchikov, N.J.; Geurts-Moespot, A.; Heijmen, L.; Laarhoven, H.W.M. van; Herpen, C.M.L. van; Thijs, A.M.J.; Span, P.N.; Sweep, F.C.

    2014-01-01

    BackgroundThe use of therapeutic monoclonal antibodies for clinical purposes has significantly increased in recent years, and so has the need to monitor antibody concentrations. This may be achieved using the well-established enzyme linked immunoassay (ELISA) methods; however, these assays are

  17. Development of functionally-oriented technological processes of electroerosive processing

    Science.gov (United States)

    Syanov, S. Yu

    2018-03-01

    The stages of the development of functionally oriented technological processes of electroerosive processing from the separation of the surfaces of parts and their service functions to the determination of the parameters of the process of electric erosion, which will provide not only the quality parameters of the surface layer, but also the required operational properties, are described.

  18. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots

    International Nuclear Information System (INIS)

    Chen, Rui; Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua; Xiong, Yonghua

    2016-01-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H_2O_2) and H_2O_2-sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H_2O_2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H_2O_2, as well as the incubation time between H_2O_2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10"2 CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10"3 CFU/mL to 1.18 × 10"6 CFU/mL were in the range of 65.88%–105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. - Highlights: • A novel fluorescence immunoassay was developed for the ultrasensitive detection of E. coli O157:H7. • This detection was achieved through the combination of the high bioactivity of CAT and H_2O_2-sensitive QDs. • The activity of CAT to H_2O_2 is 1000 folds higher than that of the HRP to tetramethylbenzidine. • The limit of detection of the proposed method could

  19. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children.

    Science.gov (United States)

    Karbasy, Kimiya; Lin, Danny C C; Stoianov, Alexandra; Chan, Man Khun; Bevilacqua, Victoria; Chen, Yunqi; Adeli, Khosrow

    2016-04-01

    The CALIPER program is a national research initiative aimed at closing the gaps in pediatric reference intervals. CALIPER previously reported reference intervals for endocrine and special chemistry markers on Abbott immunoassays. We now report new pediatric reference intervals for immunoassays on the Beckman Coulter Immunoassay Systems and assess platform-specific differences in reference values. A total of 711 healthy children and adolescents from birth to reference intervals calculated in accordance with Clinical and Laboratory Standards Institute (CLSI) EP28-A3c guidelines. Complex profiles were observed for all 29 analytes, necessitating unique age and/or sex-specific partitions. Overall, changes in analyte concentrations observed over the course of development were similar to trends previously reported, and are consistent with biochemical and physiological changes that occur during childhood. Marked differences were observed for some assays including progesterone, luteinizing hormone and follicle-stimulating hormone where reference intervals were higher than those reported on Abbott immunoassays and parathyroid hormone where intervals were lower. This study highlights the importance of determining reference intervals specific for each analytical platform. The CALIPER Pediatric Reference Interval database will enable accurate diagnosis and laboratory assessment of children monitored by Beckman Coulter Immunoassay Systems in health care institutions worldwide. These reference intervals must however be validated by individual labs for the local pediatric population as recommended by CLSI.

  20. Analytical evaluation of the novel Lumipulse G BRAHMS procalcitonin immunoassay.

    Science.gov (United States)

    Ruzzenente, Orazio; Salvagno, Gian Luca; Gelati, Matteo; Lippi, Giuseppe

    2016-12-01

    This study was designed to evaluate the analytical performance of the novel Lumipulse G1200 BRAHMS procalcitonin (PCT) immunoassay. This analytical evaluation encompassed the calculation of the limit of blank (LOB), limit of detection (LOD), functional sensitivity, intra- and inter-assay imprecision, confirmation of linearity and a comparison with the Vidas BRAHMS PCT assay. The LOB, LOD and functional sensitivity were 0.0010 ng/mL, 0.0016 ng/mL and 0.008 ng/mL, respectively. The total analytical imprecision was found to be 2.1% and the linearity was excellent (r=1.00) in the range of concentrations between 0.006-75.5 ng/mL. The correlation coefficient with Vidas BRAHMS PCT was 0.995 and the equation of the Passing and Bablok regression analysis was [Lumipulse G BRAHMS PCT]=0.76×[Vidas BRAHMS PCT]+0.04. The mean overall bias of Lumipulse G BRAHMS PCT versus Vidas BRAHMS PCT was -3.03 ng/mL (95% confidence interval [CI]: -4.32 to -1.74 ng/mL), whereas the mean bias in samples with PCT concentration between 0-10 ng/mL was -0.49 ng/mL (95% CI: -0.77 to -0.24 ng/mL). The diagnostic agreement was 100% at 0.5 ng/mL, 97% at 2.0 ng/mL and 95% at 10 ng/mL, respectively. These results attest that Lumipulse G BRAHMS PCT exhibits excellent analytical performance, among the best of the methods currently available on the diagnostic market. However, the significant bias compared to the Vidas BRAHMS PCT suggests that the methods cannot be used interchangeably.

  1. Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function

    Science.gov (United States)

    2017-10-01

    impact on society beyond science and technology ? Nothing to report at this time. 5. CHANGES/PROBLEMS: Changes in approach and reasons for...AWARD NUMBER: W81XWH-16-1-0785 TITLE: Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function...2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function 5a

  2. Executive functions and parent-child interaction during technology-enhanced storytelling

    NARCIS (Netherlands)

    Horvers, A.; Molenaar, I.; Teepe, R.C.; Verhoeven, L.T.W.

    2017-01-01

    This study explores how children's executive functions influences the way parent and child engage in a technology-enhanced story telling activity (TES). Research has indicated that children's executive functions (inhibitory control, memory and cognitive flexibility) are related to how they engage in

  3. A direct radio-immunoassay for plasma aldosterone: significance of endogenous cortisol

    International Nuclear Information System (INIS)

    Man, A.J.M. de; Hofman, J.A.; Hendriks, Th.; Rosmalen, F.M.A.; Ross, H.A.; Benraad, Th.J.

    1980-01-01

    A direct radio-immunoassay for plasma aldosterone was developed, using a highly specific antiserum raised in sheep. An excellent correlation was observed between its results and the levels measured after extraction and chromatography. The necessity of including a blocking agent to inhibit the binding of aldosterone to plasma proteins was investigated. It was found that in low-cortisol ( 10 μg/100 ml) the final assay result was independent of the presence of ANS. The effect of cortisol was interpreted in terms of its influence on aldosterone binding to plasma proteins in the absence of a blocking agent. (Auth.)

  4. Quantification of patient-specific assay interference in different formats of enzyme-linked immunoassays for therapeutic monoclonal antibodies

    NARCIS (Netherlands)

    Grebenchtchikov, Nicolai; Geurts-Moespot, Anneke J.; Heijmen, Linda; van Laarhoven, Hanneke W. M.; van Herpen, Carla M. L.; Thijs, Annemarie M. J.; Span, Paul N.; Sweep, Fred C. G. J.

    2014-01-01

    The use of therapeutic monoclonal antibodies for clinical purposes has significantly increased in recent years, and so has the need to monitor antibody concentrations. This may be achieved using the well-established enzyme linked immunoassay (ELISA) methods; however, these assays are subject to a

  5. Horseradish peroxidase-loaded nanospheres attached to hollow gold nanoparticles as signal enhancers in an ultrasensitive immunoassay for alpha-fetoprotein

    International Nuclear Information System (INIS)

    Li, Ya; Yuan, Ruo; Chai, Yaqin; Zhuo, Ying; Su, Huilan; Zhang, Yuxia

    2014-01-01

    We report on a novel electrochemical signal amplification strategy for use in immunoassays. The highly responsive immunoelectrode was constructed in the following way: (1) The surface of a gold electrode was covered with a layer single-walled carbon nanotubes dispersed in chitosane functionalized with L-cysteine; (2) Gold nanoparticles containing protein A and anti-alpha-fetoprotein (anti-AFP) were then covalently attached to the surface via the thiol groups of the chitosane. The electrode is then exposed to the analyte (AFP) which then is bound by the antibody. In the next step, a gold-conjugated secondary antibody is added that was prepared in the following way: (1) Horseradish peroxidase was crosslinked and the resulting spheres were coated with hollow gold nanoparticles (hollow Au-NPs) to give nanospheres of ∼100 nm in diameter. (2) These were the coated with thionine and, in a last step, with secondary antibody. The use of these materials has several attractive features: The HRP-NPs functionalized with hollow Au-NPs possess a large surface area that can load the large amount of secondary antibody. Thionine (Thi) is highly redox active and improves the intensity of the signal. Carbon nanotubes were used because they possess an excellent electron transfer rate and large surface area. Following incubation of the modified electrode (a) with a sample containing AFP, (b) then with the secondary antibody, and (c) with washing buffer, the electrode is placed in a solution containing H 2 O 2 . The HRP in the smart secondary antibody causes the catalytic decomposition of H 2 O 2 and the results in an electrical current that is linearly related to the concentration of AFP in the 0.025 to 5.0 ng mL −1 concentration range. The detection limit for AFP is as low as 8.3 pg mL −1 . We believe that this novel kind of immunoassay represents a promising tool for use in sensitive clinical assays. (author)

  6. Comparative studies on the determination of alphafetoprotein by enzyme immunoassay and by radioimmunoassay

    International Nuclear Information System (INIS)

    Haller, G.; Linneke, P.; Voss, P.; Jeske, W.

    1987-01-01

    Alphafetoprotein (AFP) was determined in serum of pregnant women in the tenth till sixteenth week of pregnancy by means of two enzyme immunoassays (Enzymun-Test AFP, Boehringer Mannheim, FRG and AFP EIA 'Dessau' 1000, Research Institute for Vaccine Dessau, GDR) and a radioimmunoassay (Radioimmunoassay Kit, AFP-PR, CIS, France). Parallel determinations in sera of 438 patients, who had come to surveillance for the first consultation were estimated. A comparison between the methods showed a good correlation. (author)

  7. Functionalization of SU-8 photoresist surfaces with IgG proteins

    International Nuclear Information System (INIS)

    Blagoi, Gabriela; Keller, Stephan; Johansson, Alicia; Boisen, Anja; Dufva, Martin

    2008-01-01

    The negative epoxy-based photoresist SU-8 has a variety of applications within microelectromechanical systems (MEMS) and lab-on-a-chip systems. Here, several methods to functionalize SU-8 surfaces with IgG proteins were investigated. Fluorescent labeled proteins and fluorescent sandwich immunoassays were employed to characterize the binding efficiency of model proteins to bare SU-8 surface, SU-8 treated with cerium ammonium nitrate (CAN) etchant and CAN treated surfaces modified by aminosilanization. The highest binding capacity of antibodies was observed on bare SU-8. This explains why bare SU-8 in a functional fluorescent sandwich immunoassay detecting C-reactive protein (CRP) gave twice as high signal as compared with the other two surfaces. Immunoassays performed on bare SU-8 and CAN treated SU-8 resulted in detection limits of CRP of 30 and 80 ng/ml respectively which is sufficient for detecting CRP in clinical samples, where concentrations of 3-10 μg/ml are normal for healthy individuals. In conclusion, bare SU-8 and etched SU-8 can be modified with antibodies by a simple adsorption procedure which simplifies building lab-on-a-chip systems in SU-8. Additionally, we report the fabrication process and use of microwells created in a SU-8 layer with the same dimensions as a standard microscope glass slide that could fit into fluorescent scanners. The SU-8 microwells minimize the reagent consumption and are straightforward to handle compared to SU-8 coated microscope slides

  8. Plasma myelin basic protein assay using Gilford enzyme immunoassay cuvettes.

    Science.gov (United States)

    Groome, N P

    1981-10-01

    The assay of myelin basic protein in body fluids has potential clinical importance as a routine indicator of demyelination. Preliminary details of a competitive enzyme immunoassay for this protein have previously been published by the author (Groome, N. P. (1980) J. Neurochem. 35, 1409-1417). The present paper now describes the adaptation of this assay for use on human plasma and various aspects of routine data processing. A commercially available cuvette system was found to have advantages over microtitre plates but required a permuted arrangement of sample replicates for consistent results. For dose interpolation, the standard curve could be fitted to a three parameter non-linear equation by regression analysis or linearised by the logit/log transformation.

  9. Magnetophoretic separation ICP-MS immunoassay using Cs-doped multicore magnetic nanoparticles for the determination of salmonella typhimurium.

    Science.gov (United States)

    Jeong, Arong; Lim, H B

    2018-02-01

    In this work, a magnetophoretic separation ICP-MS immunoassay using newly synthesized multicore magnetic nanoparticles (MMNPs) was developed for the determination of salmonella typhimurium (typhi). The uniqueness of this method was the use of MMNPs doped with Cs for both separation and detection, which enable us to achieve fast analysis, high sensitivity, and good reliability. For demonstration, heat-killed typhi in a phosphate buffer solution was determined by ICP-MS after the MMNP-typhi reaction product was separated from unreacted MMNPs in a micropipette tip filled with 25% polyethylene glycol through magnetophoretic separation. The calibration curve obtained by plotting 133 Cs intensity vs. the number of synthetic standard, showed a coefficient of determination (R 2 ) of 0.94 with a limit of detection (LOD) of 102 cells/mL without cell culturing. Excellent recoveries, between 98-100%, were obtained from four replicates and compared with a sandwich-type ICP-MS immunoassay for further confirmation. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Clinical development of placental malaria vaccines and immunoassays harmonization

    DEFF Research Database (Denmark)

    Chêne, Arnaud; Houard, Sophie; Nielsen, Morten A

    2016-01-01

    Placental malaria caused by Plasmodium falciparum infection constitutes a major health problem manifesting as severe disease and anaemia in the mother, impaired fetal development, low birth weight or spontaneous abortion. Prevention of placental malaria currently relies on two key strategies...... that are losing efficacy due to spread of resistance: long-lasting insecticide-treated nets and intermittent preventive treatment during pregnancy. A placental malaria vaccine would be an attractive, cost-effective complement to the existing control tools. Two placental malaria vaccine candidates are currently...... in Phase Ia/b clinical trials. During two workshops hosted by the European Vaccine Initiative, one in Paris in April 2014 and the other in Brussels in November 2014, the main actors in placental malaria vaccine research discussed the harmonization of clinical development plans and of the immunoassays...

  11. Correlation of antinuclear antibody immunofluorescence patterns with immune profile using line immunoassay in the Indian scenario

    Directory of Open Access Journals (Sweden)

    Sebastian Wendy

    2010-07-01

    Full Text Available Background: Immunity status, individual response to disease and types of antibodies produced are well known to vary from person to person, place to place and probably from population to population. A broad spectrum of specific auto antibodies that have so far been associated with specific rheumatic diseases, as noted in Western literature, has been well taken as a reference standard all over the world. There is neither research work nor any data correlating the auto antibodies and their antinuclear antibody (ANA patterns with the immunoprofile in the Indian population to date. Aims: To understand a definite association between ANA patterns and specific antibodies in the serum in the Indian study population and to document similarities / differences with the West. Settings and Design: This prospective and retrospective double blind study was undertaken on the South Indian population referred for ANA testing by Indirect Immunofluorescence method and by immunoline methods. Materials and Methods: Serum samples of patients from a random South Indian population who sought medical help for rheumatic disease were subjected for ANA testing by indirect immunofluorescence (IIF method and line immunoassay during the study period of 27 months. Serum samples were processed in dilution of 1:100 using HEp - 2010 / liver biochip (Monkey (EUROIMMUN AG. The serum samples which were further processed for line immunoassay were treated in 1:100 dilution on nylon strips coated with recombinant and purified antigens as discrete lines with plastic backing (EUROIMMUN AG coated with antigens nRNP / Sm, Sm, SSA, Ro-52, SSB, Scl-70, PM-Scl, PCNA, Jo-1, CENP-B, dsDNA, nucleosomes, histones, ribosomal protein-P, anti-mitochondrial antibodies (AMA-M2 along with a control band. The analysis was done by comparing the intensity of the reaction with positive control line by image analysis. Results: The antinuclear antibody indirect immunofluorescence (ANA - IIF patterns obtained

  12. Enhanced Plasmonic Biosensors of Hybrid Gold Nanoparticle-Graphene Oxide-Based Label-Free Immunoassay

    Science.gov (United States)

    Chiu, Nan-Fu; Chen, Chi-Chu; Yang, Cheng-Du; Kao, Yu-Sheng; Wu, Wei-Ren

    2018-05-01

    In this study, we propose a modified gold nanoparticle-graphene oxide sheet (AuNP-GO) nanocomposite to detect two different interactions between proteins and hybrid nanocomposites for use in biomedical applications. GO sheets have high bioaffinity, which facilitates the attachment of biomolecules to carboxyl groups and has led to its use in the development of sensing mechanisms. When GO sheets are decorated with AuNPs, they introduce localized surface plasmon resonance (LSPR) in the resonance energy transfer of spectral changes. Our results suggest a promising future for AuNP-GO-based label-free immunoassays to detect disease biomarkers and rapidly diagnose infectious diseases. The results showed the detection of antiBSA in 10 ng/ml of hCG non-specific interfering protein with dynamic responses ranging from 1.45 nM to 145 fM, and a LOD of 145 fM. Considering the wide range of potential applications of GO sheets as a host material for a variety of nanoparticles, the approach developed here may be beneficial for the future integration of nanoparticles with GO nanosheets for blood sensing. The excellent anti-interference characteristics allow for the use of the biosensor in clinical analysis and point-of-care testing (POCT) diagnostics of rapid immunoassay products, and it may also be a potential tool for the measurement of biomarkers in human serum.

  13. Anti-idiotypic nanobody-alkaline phosphatase fusion proteins: Development of a one-step competitive enzyme immunoassay for fumonisin B_1 detection in cereal

    International Nuclear Information System (INIS)

    Shu, Mei; Xu, Yang; Liu, Xing; Li, Yanping; He, Qinghua; Tu, Zhui; Fu, Jinheng; Gee, Shirley J.; Hammock, Bruce D.

    2016-01-01

    A rapid and sensitive one-step competitive enzyme immunoassay for the detection of FB_1 was developed. The anti-idiotypic nanobody–alkaline phosphatase (Ab2β−Nb−AP) was validated by the AP enzyme activity and the properties of bounding to anti-FB1-mAb (3F11) through colorimetric and chemiluminescence analyses. The 50% inhibitory concentration and the detection limit (LOD) of colorimetric enzyme-linked immunosorbent assay (ELISA) for FB_1 were 2.69 and 0.35 ng mL"−"1, respectively, with a linear range of 0.93–7.73 ng mL"−"1. The LOD of the chemiluminescence ELISA (CLIA) was 0.12 ng mL"−"1, and the IC_5_0 was 0.89 ± 0.09 ng mL"−"1 with a linear range of 0.29–2.68 ng mL"−"1. Compared with LC-MS/MS, the results of this assay indicated the reliability of the Ab2β−Nb−AP fusion protein based one-step competitive immunoassay for monitoring FB_1 contamination in cereals. The Ab2β−Nb−AP fusion proteins have the potential to replace chemically-coupled probes in competitive enzyme immunoassay systems. - Highlights: • Ab2β−Nb−AP has the potential to replace chemically-coupled probes. • Ab2β−Nb−AP is homogeneous enzyme-labelled antigen can be prepared reproducibly. • We developed a green and rapid one-step competitive enzyme immunoassay. • The sensitivity of one-step CLIA was 9-folds higher than two-step ELISA.

  14. One-step synthesis of redox-active polymer/AU nanocomposites for electrochemical immunoassay of multiplexed tumor markers.

    Science.gov (United States)

    Liu, Zhimin; Rong, Qinfeng; Ma, Zhanfang; Han, Hongliang

    2015-03-15

    In this work, a simple and sensitive multiplexed immunoassay protocol for simultaneous electrochemical determination of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) was designed using redox-active nanocomposites. As the redox-active species, the poly(o-phenylenediamine) (POPD)/Au nanocomposite and poly(vinyl ferrocene-2-aminothiophenol) (poly(VFc-ATP))/Au nanocomposite were obtained by one-step method which HAuCl4 was used as the oxidant. With Au nanoparticles (AuNPs), the nanocomposites were successful to immobilize labeled anti-CEA and anti-AFP as the immunosensing probes. The proposed electrochemical immunoassay enabled the simultaneous monitoring of AFP and CEA in a wide range of 0.01-100ngmL(-1). The detection limits was 0.006ngmL(-1) for CEA and 0.003ngmL(-1) for AFP (S/N=3). The assay results of serum samples with the proposed method were well consistent with the reference values from standard ELISA method. And the negligible cross-reactivity between the two analytes makes it possesses potential promise in clinical diagnosis. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. New technologies for large-scale micropatterning of functional nanocomposite polymers

    Science.gov (United States)

    Khosla, A.; Gray, B. L.

    2012-04-01

    We present a review of different micropatterning technologies for flexible elastomeric functional nanocomposites with a particular emphasis on mold material and processes for production of large size substrates. The functional polymers include electrically conducting and magnetic materials developed at the Micro-instrumentation Laboratory at Simon Fraser University, Canada. We present a chart that compares many of these different conductive and magnetic functional nanocomposites and their measured characteristics. Furthermore, we have previously reported hybrid processes for nanocomposite polymers micromolded against SU-8 photoepoxy masters. However, SU-8 is typically limited to substrate sizes that are compatible with microelectronics processing as a microelectronics uv-patterning step is typically involved, and de-molding problems are observed. Recently, we have developed new processes that address the problems faced with SU-8 molds. These new technologies for micropatterning nanocomposites involve new substrate materials. A low cost Poly(methyl methacrylate) (PMMA) microfabrication technology has been developed, which involves fabrication of micromold via either CO2 laser ablation or deep UV. We have previously reported this large-scale patterning technique using laser ablation. Finally, we compare the two processes for PMMA producing micromolds for nanocomposites.

  16. Characterization of hapten-protein conjugates: antibody generation and immunoassay development for chlorophenoxyacetic acid pesticides.

    Science.gov (United States)

    Boro, Robin C; Singh, K Vikas; Suri, C Raman

    2009-01-01

    The generation of specific and sensitive antibodies against small molecules is greatly dependent upon the characteristics of the hapten-protein conjugates. In this study, we report a new fluorescence-based method for the characterization of hapten-protein conjugates. The method is based on an effect promoted by hapten-protein conjugation density upon the fluorescence intensity of the intrinsic tryptophan chromophore molecules of the protein. The proposed methodology is applied to quantify the hapten-protein conjugation density for two different chlorophenoxyacetic acid pesticides, 2,4-dichlorophenoxyacetic acid (2,4-D) and 2,4-dichlorophenoxybutyric acid (2,4-DB), coupled to carrier protein. Highly sensitive anti-2,4-D and anti-2,4-DB antibodies were obtained using these well-characterized hapten-protein conjugates. The generated antibodies were used in an immunoassay format demonstrating inhibitory concentration (IC50) values equal to 30 and 7 ng/mL for 2,4-D and 2,4-DB, respectively. Linearity was observed in the concentration range between 0.1-500 nglmL with LODs around 4 and 3 ng/mL for 2,4-D and 2,4-DB, respectively, in standard water samples. The proposed method was successfully applied for the determination of the extent of hapten-protein conjugation to produce specific antibodies for immunoassay development against pesticides.

  17. Comparison of immunoassays for differentiation of herpes simplex virus type 1 and 2 antibodies

    International Nuclear Information System (INIS)

    Klapper, Paul E.; Valley, Pam J.; Cleator, Gerham M.; Mandall, D.; Qutub, Mohammed O.

    2006-01-01

    To asses the commercial available enzyme-linked immunosorbent assays (ELISA) for differentiation of herpes simplex virus type 1 (Hs-1) and type 2 (HSV-2) antibodies. The study was performed between January 1997 to November 2002 in the Division ofVirology,Department of Pathological Sciences, Central Manchester Healthcare Trust and University of Manchester, Manchester, United Kingdom. Assays based upon type-specific glycoprotein G-1 (gG-1) for HSV-1, and glycoprotein G-2 (gG-2) from HSV-2 were evaluated to differentiate between HSV-1 and HSV-2 antibodies. Using 5 different ELISA tests, 2 panels of serum samples were tested. Panel one consisted of 88 sera, selected from the serum bank of the Clinical Virology Laboratory, Manchester Royal Infirmary; panel 2 comprised of 90 sera selected from samples collected from Bangladeshi female commercial workers.The data of this study showed that a high rate of gG-1 based immunoassays ranged from 87.9-100% for sensitivity and 51.5-100% specificity. Although there are several immunoassays were claimed to differentiate between HSV-1 and HSV-2 antibodies, selection of these assays should be carefully interpreted with the overall clinical framework provided by detailed sexual history and genital examination. (author)

  18. An exploration of options and functions of climate technology centres and networks. Discussion paper

    International Nuclear Information System (INIS)

    De Coninck, H.C.; Wuertenberger, L.; Cochran, J.; Cox, S.; Benioff, R.

    2010-11-01

    This paper responds to a request to UNEP from the UNFCCC Expert Group on Technology Transfer to examine operational modalities for climate technology centres and networks. The paper first discusses possible dimensions for the climate technology centre and network, and it reviews a number of existing networks and centres. It then distinguishes five options for the organizational structure and describes potential operational characteristics for each of these options. All options examined seek to build from existing climate and non-climate-related public and private technology centres, networks, and initiatives. Consistent with the UNFCCC negotiating text and draft technology decision, the paper evaluates potential implementation options and outcomes for each of the functions tentatively assigned to the climate technology centre and network, as well as selected functions of the technology executive committee. Approaches are offered for integrating delivery of these functions through coordinated programmes, and hypothetical examples are given to explain how the technology mechanism might add value in practice. The options presented in this paper are not an exhaustive treatment of potential structures or implementation approaches, and other approaches can be considered.

  19. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  20. Characterization of the scope and magnitude of biotin interference in susceptible Roche Elecsys competitive and sandwich immunoassays.

    Science.gov (United States)

    Trambas, Christina; Lu, Zhong; Yen, Tina; Sikaris, Ken

    2018-03-01

    Background Biotin interference is a significant problem to which at-risk laboratories must now be attuned. We sought to systematically characterize the nature of this interference in Roche immunoassays. Methods Known concentrations of biotin were titrated into serum samples and the effects on competitive and sandwich immunoassays were analysed. The maximum and minimum concentrations examined reflect those likely to be achieved in individuals on 5 to 10 mg supplements at the lower end, and 100 to 300 mg biotin at the high end. Results A high variability in biotin tolerance was observed. Some assays, such as troponin T, TSH and antithyroid antibodies, were extremely sensitive to the lower concentrations of biotin (15.6 and 31.3 ng/mL), whereas the majority of assays were relatively resistant. At concentrations ≥500 ng/mL, all assays showed significant interference from biotin but, again, the magnitude of the interference was variable. The more sensitive assays showed profound analytical bias at biotin concentrations that occur with high-dose therapy. Conclusion Our data demonstrate high variability in biotin tolerance across Roche immunoassays. The shape of the dose-response curves provides more detailed information than the single manufacturer-quoted figure for biotin tolerance. Accordingly, these data may be used by laboratories for more accurate risk assessment in predicting the effects of biotin. Our data may also be extrapolated to guide timing of blood tests in patients on high-dose biotin therapy: it demonstrates the number of half-lives required to withhold biotin in order to decrease its concentration to below a given assay tolerance.

  1. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Rui [College of Life Science, Nanchang University, Nanchang, 330031 (China); State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua [State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Xiong, Yonghua, E-mail: yhxiongchen@163.com [College of Life Science, Nanchang University, Nanchang, 330031 (China); State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China)

    2016-12-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H{sub 2}O{sub 2}) and H{sub 2}O{sub 2}-sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H{sub 2}O{sub 2} and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H{sub 2}O{sub 2}, as well as the incubation time between H{sub 2}O{sub 2} and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10{sup 2} CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10{sup 3} CFU/mL to 1.18 × 10{sup 6} CFU/mL were in the range of 65.88%–105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. - Highlights: • A novel fluorescence immunoassay was developed for the ultrasensitive detection of E. coli O157:H7. • This detection was achieved through the combination of the high bioactivity of CAT and H{sub 2}O{sub 2}-sensitive QDs. • The activity of CAT to H{sub 2}O{sub 2} is 1000 folds higher than that of the HRP

  2. Improving the sensitivity of immunoassay based on MBA-embedded Au@SiO2 nanoparticles and surface enhanced Raman spectroscopy

    Science.gov (United States)

    Wei, Chao; Xu, Min-Min; Fang, Cong-Wei; Jin, Qi; Yuan, Ya-Xian; Yao, Jian-Lin

    2017-03-01

    Traditional "sandwich" structure immunoassay is mainly based on the self-assembly of "antibody on solid substrate-antigen-antibody with nanotags" architectures, and the sensitivity of this strategy is critically depended on the surface enhanced Raman scattering (SERS) activities and stability of nanotags. Therefore, the rational design and fabrication on the SERS nanotags attracts the common interests to the bio-related detecting and imaging. Herein, silica encapsulated Au with mercaptobenzoic acid (MBA) core-shell nanoparticles (Au-MBA@SiO2) are fabricated instead of the traditional naked Au or Ag nanoparticles for the SERS-based immunoassay on human and mouse IgG antigens. The MBA molecules facilitate the formation of continuous pinhole-free silica shell and are also used as SERS labels. The silica shell is employed to protect MBA labels and to isolate Au core from the ambient solution for blocking the aggregation. This shell also played the similar role to BSA in inhibiting the nonspecific bindings, which allowed the procedures for constructing "sandwich" structures to be simplified. All of these merits of the Au-MBA@SiO2 brought the high performance in the related immunoassay. Benefiting from the introduction of silica shell to encapsulate MBA labels, the detection sensitivity was improved by about 1- 2 orders of magnitude by comparing with the traditional approach based on naked Au-MBA nanoparticles. This kind of label-embedded core-shell nanoparticles could be developed as the versatile nanotags for the bioanalysis and bioimaging.

  3. Research of the complex of functional and technological properties of animal protein

    Directory of Open Access Journals (Sweden)

    Олена Борисівна Дроменко

    2016-12-01

    Full Text Available The analysis of the results of analytical and practical research of the complex of functional and technological properties of animal protein Gelexcel A-95 as the basis for creation of complex functional additives is shown. The regularities of their changes are determined depending on technological factors. Rational parameters of animal protein rehydration, gelation conditions, emulsification for further use in the process of production of meat products are identified

  4. Sensitive, Fast, and Specific Immunoassays for Methyltestosterone Detection

    Directory of Open Access Journals (Sweden)

    Na Kong

    2015-04-01

    Full Text Available An indirect competitive enzyme-linked immunosorbent assay (icELISA and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%–100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed.

  5. Serum gastrin: interests and limitations of radio-immunoassay

    International Nuclear Information System (INIS)

    Rougier, P.; Linhart, N.; Bok, B.

    1980-01-01

    Radio-immunoassay of serum gastrin may now be carried out in all laboratories of radio-immunology. Comparison of two commercial kits A: Schwartz-Mann and B: CEA-SORIN according to criteria of specificity, sensitivity and reproducibility within and between systems, shows that they both permit the detection of pathological hypergastrinemias (Zollinger Ellison and atropic gastritis). Both kits have an identical intrasystem coefficient of variation (10 p. cent and 7 p. cent fort A, 5 p. cent and 8 p. cent for B) on the other hand, the inter-system coefficient of variation is better for kit B (22.4 p. cent and 37 p. cent for kit A, and 11.5 p. cent and 14.2 p. cent for kit B). The normal values for each kit are quite different: 97 . 64 pg.ml -1 for A and 51 . 23 pg.ml -1 for B preventing one from comparing estimations carried out with two different kits [fr

  6. Multiple signal amplified electrochemiluminescent immunoassay for brombuterol detection using gold nanoparticles and polyamidoamine dendrimers-silver nanoribbon

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Tiantian; Hu, Liuyi; Zhao, Kang; Deng, Anping, E-mail: denganping@suda.edu.cn; Li, Jianguo, E-mail: lijgsd@suda.edu.cn

    2016-11-16

    Electrochemiluminescent (ECL) immunosensor with multiple signal amplification was designed based on gold nanoparticles (AuNPs), polyamidoamine dendrimers (PAMAM) and silver-cysteine hybrid nanoribbon (SNR). Low toxic L-cysteine capped CdSe QDs was chosen as the ECL signal probe. To verify the proposed ultrasensitive ECL immunosensor for β-adrenergic agonists (β-AA), we detected Brombuterol (Brom) as a proof-of-principle analyte. Therein, AuNPs as the substrate can simplify the experiment process, accelerate the electron transfer rate, and carry more coating antigen (Ag-OVA) to enlarge ECL signal. On one hand, SNR on the surface of electrode can avoid the aggregation of AuNPs, and SNR-PAMAM-AuNPs also can be acted as a good accelerator for electron transfer. On the other hand, PAMAM (16 -NH{sub 2}) functionalized SNR (SNR-PAMAM) with numerous amino groups could be employed to bond abundant actived QDs to further amplify ECL signal. The new immunosensor can offer a simple, reliable, rapid, and selective detection for Brom, which have a dynamic range of 0.005–700 ng mL{sup −1} with a low detection limit at 1.5 pg mL{sup −1}. The proposed biosensor will extend the application of nanomaterials in ECL immunoassays and open a new road for the detection of Brom and other β-AA in the future. - Highlights: • A multiple signal amplification ECL immunosensor of eco-friendly CdSe QDs for brombuterol determination was developed. • Besides substrates, AuNPs and PAMAM-SNR were creatively used to accelerate the electron transport between electrode and QDs. • SNR-PAMAM with numerous amino groups also could be employed to bond abundant actived QDs to amplify ECL signal. • Competitive immunoassay was performed with ECL to detect small molecules of brombuterol. • It provided a method for detecting Brom and enlarged the usage of QDs, AuNPs and SNR-PAMAM in ECL biosensing.

  7. Multiple signal amplified electrochemiluminescent immunoassay for brombuterol detection using gold nanoparticles and polyamidoamine dendrimers-silver nanoribbon

    International Nuclear Information System (INIS)

    Dong, Tiantian; Hu, Liuyi; Zhao, Kang; Deng, Anping; Li, Jianguo

    2016-01-01

    Electrochemiluminescent (ECL) immunosensor with multiple signal amplification was designed based on gold nanoparticles (AuNPs), polyamidoamine dendrimers (PAMAM) and silver-cysteine hybrid nanoribbon (SNR). Low toxic L-cysteine capped CdSe QDs was chosen as the ECL signal probe. To verify the proposed ultrasensitive ECL immunosensor for β-adrenergic agonists (β-AA), we detected Brombuterol (Brom) as a proof-of-principle analyte. Therein, AuNPs as the substrate can simplify the experiment process, accelerate the electron transfer rate, and carry more coating antigen (Ag-OVA) to enlarge ECL signal. On one hand, SNR on the surface of electrode can avoid the aggregation of AuNPs, and SNR-PAMAM-AuNPs also can be acted as a good accelerator for electron transfer. On the other hand, PAMAM (16 -NH_2) functionalized SNR (SNR-PAMAM) with numerous amino groups could be employed to bond abundant actived QDs to further amplify ECL signal. The new immunosensor can offer a simple, reliable, rapid, and selective detection for Brom, which have a dynamic range of 0.005–700 ng mL"−"1 with a low detection limit at 1.5 pg mL"−"1. The proposed biosensor will extend the application of nanomaterials in ECL immunoassays and open a new road for the detection of Brom and other β-AA in the future. - Highlights: • A multiple signal amplification ECL immunosensor of eco-friendly CdSe QDs for brombuterol determination was developed. • Besides substrates, AuNPs and PAMAM-SNR were creatively used to accelerate the electron transport between electrode and QDs. • SNR-PAMAM with numerous amino groups also could be employed to bond abundant actived QDs to amplify ECL signal. • Competitive immunoassay was performed with ECL to detect small molecules of brombuterol. • It provided a method for detecting Brom and enlarged the usage of QDs, AuNPs and SNR-PAMAM in ECL biosensing.

  8. Evaluation of two automated enzyme-immunoassays for detection of thermophilic campylobacters in faecal samples from cattle and swine

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Nielsen, E.M.; Stryhn, H.

    1999-01-01

    We evaluated the performance of two enzyme-immunoassays (EIA) for the detection of naturally occurring, thermophilic Campylobacter spp. found in faecal samples from cattle (n = 21 and n = 26) and swine (n = 43) relative to the standard culture method, and also assuming that none of the tests...

  9. Development of a nucleic acid lateral flow immunoassay for simultaneous detection of Listeria spp. and Listeriamonocytogenes in food

    NARCIS (Netherlands)

    Blazkova, M.; Koets, M.; Rauch, P.; Amerongen, van A.

    2009-01-01

    We present a new nucleic acid lateral flow immunoassay (NALFIA) for the assessment of listeria contamination. The detection procedure starts with enrichment of sample in Half Fraser broth (24 h). Following isolation of DNA, a duplex PCR is performed with two labelled primer sets, one generic and

  10. Toxicogenomics: Applications of new functional genomics technologies in toxicology

    NARCIS (Netherlands)

    Heijne, W.H.M.

    2004-01-01

    Toxicogenomics studies toxic effects of substances on organisms in relation to the composition of the genome. It applies the functional genomics technologies transcriptomics, proteomics and metabolomics that determine expression of the genes, proteins and metabolites in a sample. These methods could

  11. Development of a Nanobody-Based Lateral Flow Immunoassay for Detection of Human Norovirus.

    Science.gov (United States)

    Doerflinger, Sylvie Y; Tabatabai, Julia; Schnitzler, Paul; Farah, Carlo; Rameil, Steffen; Sander, Peter; Koromyslova, Anna; Hansman, Grant S

    2016-01-01

    Human noroviruses are the dominant cause of outbreaks of acute gastroenteritis. These viruses are usually detected by molecular methods, including reverse transcriptase PCR (RT-PCR) and enzyme-linked immunosorbent assay (ELISA). Human noroviruses are genetically and antigenically diverse, with two main genogroups that are further subdivided into over 40 different genotypes. During the past decade, genogroup 2 genotype 4 (GII.4) has dominated in most countries, but recently, viruses belonging to GII.17 have increased in prevalence in a number of countries. A number of commercially available ELISAs and lateral flow immunoassays were found to have lower sensitivities to the GII.17 viruses, indicating that the antibodies used in these methods may not have a high level of cross-reactivity. In this study, we developed a rapid Nanobody-based lateral flow immunoassay (Nano-immunochromatography [Nano-IC]) for the detection of human norovirus in clinical specimens. The Nano-IC assay detected virions from two GII.4 norovirus clusters, which included the current dominant strain and a novel variant strain. The Nano-IC method had a sensitivity of 80% and specificity of 86% for outbreak specimens. Norovirus virus-like particles (VLPs) representing four genotypes (GII.4, GII.10, GII.12, and GII.17) could be detected by this method, demonstrating the potential in clinical screening. However, further modifications to the Nano-IC method are needed in order to improve this sensitivity, which may be achieved by the addition of other broadly reactive Nanobodies to the system. IMPORTANCE We previously identified a Nanobody (termed Nano-85) that bound to a highly conserved region on the norovirus capsid. In this study, the Nanobody was biotinylated and gold conjugated for a lateral flow immunoassay (termed Nano-IC). We showed that the Nano-IC assay was capable of detecting at least four antigenically distinct GII genotypes, including the newly emerging GII.17. In the clinical setting, the

  12. Evaluation of automated enzyme immunoassays for five anticonvulsants and theophylline adapted to a centrifugal analyzer.

    Science.gov (United States)

    Urquhart, N; Godolphin, W; Campbell, D J

    1979-05-01

    We report a clinical evaluation of the enzyme immunoassay (EMIT) performed with the GEMSAEC centrifugal analyzer as compared to gas-liquid and liquid chromatography for anticonvulsant drugs and theophylline, respectively. A good correlation was obtained for all drugs, although some difficulties were experienced with one lot of reagent for ethosuximide. The analyzer has an economic advantage if many samples are being analyzed for few drugs in each sample.

  13. A harmonized immunoassay with liquid chromatography-mass spectrometry analysis in egg allergen determination.

    Science.gov (United States)

    Nimata, Masaomi; Okada, Hideki; Kurihara, Kei; Sugimoto, Tsukasa; Honjoh, Tsutomu; Kuroda, Kazuhiko; Yano, Takeo; Tachibana, Hirofumi; Shoji, Masahiro

    2018-01-01

    Food allergy is a serious health issue worldwide. Implementing allergen labeling regulations is extremely challenging for regulators, food manufacturers, and analytical kit manufacturers. Here we have developed an "amino acid sequence immunoassay" approach to ELISA. The new ELISA comprises of a monoclonal antibody generated via an analyte specific peptide antigen and sodium lauryl sulfate/sulfite solution. This combination enables the antibody to access the epitope site in unfolded analyte protein. The newly developed ELISA recovered 87.1%-106.4% ovalbumin from ovalbumin-incurred model processed foods, thereby demonstrating its applicability as practical egg allergen determination. Furthermore, the comparison of LC-MS/MS and the new ELISA, which targets the amino acid sequence conforming to the LC-MS/MS detection peptide, showed a good agreement. Consequently the harmonization of two methods was demonstrated. The complementary use of the new ELISA and LC-MS analysis can offer a wide range of practical benefits in terms of easiness, cost, accuracy, and efficiency in food allergen analysis. In addition, the new assay is attractive in respect to its easy antigen preparation and predetermined specificity. Graphical abstract The ELISA composing of the monoclonal antibody targeting the amino acid sequence conformed to LC-MS detection peptide, and the protein conformation unfolding reagent was developed. In ovalbumin determination, the developed ELISA showed a good agreement with LC-MS analysis. Consequently the harmonization of immunoassay with LC-MS analysis by using common target amino acid sequence was demonstrated.

  14. Evaluation of the FIDIS vasculitis multiplex immunoassay for diagnosis and follow-up of ANCA-associated vasculitis and Goodpasture's disease

    NARCIS (Netherlands)

    Damoiseaux, J.; Vaessen, M.; Knapen, Y.; Csernok, E.; Stegeman, C. A.; Van Paassen, P.; Tervaert, J. W. Cohen; Gershwin, ME; Shoenfeld, Y

    2007-01-01

    We have evaluated a new-multiplex immunoassay (FIDIS Vasculitis) for simultaneous detection and quantification of anti-MPO, -PR3, and -glomerular basement membrane (GBM) antibodies in diagnosis and follow-up of ANCA-associated vasculitides (AAV) and Goodpasture's disease. ANCA were determined in

  15. Normal Values of Circulating IGF-I Bioactivity in the Healthy Population: Comparison with five widely used IGF-I immunoassays

    NARCIS (Netherlands)

    M.P. Brugts (Michael); M.B. Ranke (Michael); L.J. Hofland (Leo); K. van der Wansem (Katy); K. Weber (Karin); J. Frystyk (Jan); S.W.J. Lamberts (Steven); J.A.M.J.L. Janssen (Joseph)

    2008-01-01

    textabstractBackground: IGF-I immunoassays are primarily used to estimate IGF-I bioactivity. Recently, an IGFI specific Kinase Receptor Activation Assay (KIRA) has been developed as an alternative method. However, no normative values have been established for the IGF-I KIRA. Objective: To

  16. Education technology with continuous real time monitoring of the current functional and emotional students' states

    Science.gov (United States)

    Alyushin, M. V.; Kolobashkina, L. V.

    2017-01-01

    The education technology with continuous monitoring of the current functional and emotional students' states is suggested. The application of this technology allows one to increase the effectiveness of practice through informed planning of the training load. For monitoring the current functional and emotional students' states non-contact remote technologies of person bioparameters registration are encouraged to use. These technologies are based on recording and processing in real time the main person bioparameters in a purely passive mode. Experimental testing of this technology has confirmed its effectiveness.

  17. Evaluation of a fluorescence polarographic immunoassay with increased sensitivity for measurement of low concentrations of tobramycin in serum

    NARCIS (Netherlands)

    Touw, D J; de Graaf, A I; de Goede, P

    The limits of quantitation of the assay of tobramycin in serum by the fluorescence polarization immunoassay system marketed by Abbott Laboratories (TDxFLx system) are 0.1 and 10.0 mg/L. For some pharmacokinetic studies, however, a more sensitive analysis is needed. The sensitivity of the TDxFLx

  18. Indirect competitive immunoassay for the detection of fungicide Thiabendazole in whole orange samples by Surface Plasmon Resonance.

    Science.gov (United States)

    Estevez, M-Carmen; Belenguer, Jose; Gomez-Montes, Silvia; Miralles, Javier; Escuela, Alfonso M; Montoya, Angel; Lechuga, Laura M

    2012-12-07

    A highly sensitive and specific SPR-based competitive immunoassay for the detection of Thiabendazole (TBZ) has been developed. An indirect format where a TBZ-protein conjugate is immobilized onto gold surfaces has been selected. Under the optimal conditions, a LOD of 0.67 nM (0.13 μg L(-1)) and an IC(50) of 3.2 nM (0.64 μg L(-1)) have been achieved which are comparable to the values obtained by conventional ELISA. Analysis of real samples has been attempted by first evaluating the influence of complex matrix samples coming from whole oranges and secondly measuring samples containing TBZ previously evaluated by chromatographic methods. A methanolic extraction procedure followed by a simple dilution in assay buffer has proven to be sufficient to measure orange samples using the developed immunoassay with an excellent recovery percentage. The sensitivity and the feasibility of measuring whole orange samples demonstrate the effectiveness and robustness of the SPR biosensor, which can be useful for the determination of TBZ in food at concentrations below the Maximum Residue Levels (MRLs) established by the European legislation.

  19. Analysis of Serum Total and Free PSA Using Immunoaffinity Depletion Coupled to SRM: Correlation with Clinical Immunoassay Tests

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao; Hossain, Mahmud; Schepmoes, Athena A.; Fillmore, Thomas L.; Sokoll, Lori J.; Kronewitter, Scott R.; Izmirlian, Grant; Shi, Tujin; Qian, Weijun; Leach, Robin; Thompson, Ian M.; Chan, Daniel W.; Smith, Richard D.; Kagan, Jacob; Srinivastava, Sudhir; Rodland, Karin D.; Camp, David G.

    2012-08-03

    Sandwich immunoassay is the standard technique used in clinical labs for quantifying protein biomarkers for disease detection, monitoring and therapeutic intervention. Albeit highly sensitive, the development of a specific immunoassay is rather time-consuming and associated with extremely high cost due to the requirement for paired immunoaffinity reagents of high specificity. Recently, mass spectrometry-based methods, specifically selected reaction monitoring mass spectrometry (SRM-MS), have been increasingly applied to measure low abundance biomarker candidates in tissue and biofluids, owing to high sensitivity and specificity, simplicity of assay configuration, and great multiplexing capability. In this study, we report for the first time the development of immunoaffinity depletion-based workflows and SRM-MS assays that enable sensitive and accurate quantification of total and free prostate-specific antigen (PSA) in serum without the requirement for specific PSA antibodies. With stable isotope dilution and external calibration, low ng/mL level detection of both total and free PSA was consistently achieved in both PSA-spiked female serum samples and actual patient serum samples. Moreover, comparison of the results obtained when SRM PSA assays and conventional immunoassays were applied to the same samples showed very good correlation (R2 values ranging from 0.90 to 0.99) in several independent clinical serum sample sets, including a set of 33 samples assayed in a blinded test. These results demonstrate that the workflows and SRM assays developed here provide an attractive alternative for reliably measuring total and free PSA in human blood. Furthermore, simultaneous measurement of free and total PSA and many other biomarkers can be performed in a single analysis using high-resolution liquid chromatographic separation coupled with SRM-MS.

  20. Candidate functions for advanced technology implementation in the Columbus mission planning environment

    Science.gov (United States)

    Loomis, Audrey; Kellner, Albrecht

    1988-01-01

    The Columbus Project is the European Space Agency's contribution to the International Space Station program. Columbus is planned to consist of three elements (a laboratory module attached to the Space Station base, a man-tended freeflyer orbiting with the Space Station base, and a platform in polar orbit). System definition and requirements analysis for Columbus are underway, scheduled for completion in mid-1990. An overview of the Columbus mission planning environment and operations concept as currently defined is given, and some of the challenges presented to software maintainers and ground segment personnel during mission operators are identified. The use of advanced technologies in system implementation is being explored. Both advantages of such solutions and potential problems they present are discussed, and the next steps to be taken by Columbus before targeting any functions for advanced technology implementation are summarized. Several functions in the mission planning process were identified as candidates for advanced technology implementation. These range from expert interaction with Columbus' data bases through activity scheduling and near-real-time response to departures from the planned timeline. Each function is described, and its potential for advanced technology implementation briefly assessed.

  1. Highly sensitive immunoassay of protein molecules based on single nanoparticle fluorescence detection in a nanowell

    Science.gov (United States)

    Han, Jin-Hee; Kim, Hee-Joo; Lakshmana, Sudheendra; Gee, Shirley J.; Hammock, Bruce D.; Kennedy, Ian M.

    2011-03-01

    A nanoarray based-single molecule detection system was developed for detecting proteins with extremely high sensitivity. The nanoarray was able to effectively trap nanoparticles conjugated with biological sample into nanowells by integrating with an electrophoretic particle entrapment system (EPES). The nanoarray/EPES is superior to other biosensor using immunoassays in terms of saving the amounts of biological solution and enhancing kinetics of antibody binding due to reduced steric hindrance from the neighboring biological molecules. The nanoarray patterned onto a layer of PMMA and LOL on conductive and transparent indium tin oxide (ITO)-glass slide by using e-beam lithography. The suspension of 500 nm-fluorescent (green emission)-carboxylated polystyrene (PS) particles coated with protein-A followed by BDE 47 polyclonal antibody was added to the chip that was connected to the positive voltage. The droplet was covered by another ITO-coated-glass slide and connected to a ground terminal. After trapping the particles into the nanowells, the solution of different concentrations of anti-rabbit- IgG labeled with Alexa 532 was added for an immunoassay. A single molecule detection system could quantify the anti-rabbit IgG down to atto-mole level by counting photons emitted from the fluorescent dye bound to a single nanoparticle in a nanowell.

  2. Evaluation of the on-site immunoassay drug-screening device Triage-TOX in routine forensic autopsy.

    Science.gov (United States)

    Tominaga, Mariko; Michiue, Tomomi; Maeda, Hitoshi

    2015-11-01

    Instrumental identification of drugs with quantification is essential in forensic toxicology, while on-site immunoassay urinalysis drug-screening devices conveniently provide preliminary information when adequately used. However, suitable or sufficient urine specimens are not always available. The present study evaluated the efficacy of a new on-site immunoassay drug-screening device Triage-TOX (Alere Inc., San Diego, CA, USA), which has recently been developed to provide objective data on the one-step automated processor, using 51 urine and 19 pericardial fluid samples from 66 forensic autopsy cases, compared with Triage-Drug of Abuse (DOA) and Monitect-9. For benzodiazepines, the positive predictive value and specificity of Triage-TOX were higher than those of Triage-DOA; however, sensitivity was higher with Monitect-9, despite frequent false-positives. The results for the other drugs with the three devices also included a few false-negatives and false-positives. These observations indicate the applicability of Triage-TOX in preliminary drug screening using urine or alternative materials in routine forensic autopsy, when a possible false-negative is considered, especially for benzodiazepines, providing objective information; however, the combined use of another device such as Monitect-9 can help minimize misinterpretation prior to instrumental analysis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Development of a mass spectrometry immunoassay for unambiguous detection of egg allergen traces in wines.

    Science.gov (United States)

    Pilolli, Rosa; Chaudhari, Ravindra; Palmisano, Francesco; Monaci, Linda

    2017-02-01

    A mass spectrometry immunoassay (MSIA) specifically designed for the detection of egg allergens in wines is described. MSIA is based on an immunoaffinity enrichment procedure combined with targeted MS/MS detection of selected egg peptide markers. Polyclonal antibodies raised against native ovalbumin, chosen as the target protein tracing for egg powder, were immobilized onto low backpressure monolithic MSIA customized disposable tips. Ovalbumin-free wine samples were fortified with standard protein at different concentrations in the low microgram-per-milliliter range. A simple protocol was devised consisting of a 1:4 dilution of the wine sample with a basic solution for pH adjustment, followed by a semi-automated purification/enrichment step on MSIA customized disposable tips fitted on a multichannel electronic pipette. Among the main figures of merit, LOD and LOQ values as low as 0.01 and 0.03 μg/mL, respectively, and within-day precision of 18% should be noticed. Noteworthy, the developed assay outperformed current MS-based methods for the detection of allergenic protein in wine matrices, thanks to the immunoaffinity enrichment. In addition, compared to other immunoassays, the present approach boasts the unquestionable advantage of providing an unambiguous identification of the target protein by simultaneous detection of three unique peptide markers each giving three specific MS/MS transitions.

  4. Development and application of radioimmunoassay and enzyme immunoassays in microbiological and immunological diagnosis. 3. Comparative studies for the detection of virus antibodies with passive hemagglutination test, radioimmunoassay and enzyme immunoassay, resp

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, H; Struy, H; Morenz, J [Medizinische Akademie, Magdeburg (German Democratic Republic)

    1982-06-01

    Radioimmuno- and enzyme immunoassays (solid phase RIA and ELISA) developed by the authors for the determination of antibodies of adeno-2- and parainfluenza-1-viruses are described and the detection sensibility for antibodies is compared with that of the conventional passive hemagglutination test. The sensibility of the radioimmunoassay for the detection of IgG antibodies against adeno-2-viruses is nearly 10 times higher than that of the passive hemagglutination. RIA and ELISA show no essential differences in their detection sensibilities in the detection of IgG antibodies against parainfluenza-1-viruses.

  5. Vitamin B(12) Immunoassay on Roche Elecsys 2010: Effects of High Excess Concentration of Serum Vitamin B(12) in CKD Patients on Parenteral Administration.

    Science.gov (United States)

    Basu, Surupa; Chaudhuri, Subimal

    2011-10-01

    Vitamin B(12) being water soluble is excreted in the urine when administered in excess. The probability of finding an abnormally excess serum concentration would be almost surreal. We report a peculiar clinical situation that may impact the vitamin B(12) immunoassay on the Roche Elecsys 2010 due to excess analyte concentration. In separate episodes (Feb and June 2010), the Biochemistry laboratory of a tertiary-care hospital, Kolkata, India, encountered two critically ill patients with background chronic kidney disease (CKD), low urine output, and on cyanocoabalamin supplementation, who had serum vitamin B(12) concentrations far exceeding expected values; even post dialysis. The B(12) assays (pmol/l) were performed using electrochemiluminiscence immunoassay on Roche Elecsys 2010, the assay validity confirmed by concomitant quality control runs. The immunoassays failed to deliver results, flagged with "signal level below limit". Biotin therapy was ruled out as a possible interferent. In the first episode, re-assay of a repeat draw yielded same outcome; outsourcing on Immulite provided concentration of >738 pmol/l. Serial dilution gave result of >29520 pmol/l on Elecsys 2010. In the second, we gained from past experience. Vitamin B(12) concentration >59040 pmol/l was conveyed to the treating nephrologist the very day. The B(12) immunoassay on the Elecsys 2010 employs sequential incubation steps for competitive binding that is compromised in the event of abnormally excess B(12) concentration in patient sera akin to the prozone effect. This knowledge may be beneficial while assaying sera of CKD patients to avoid financial loss due unnecessary repeats and delay in turnaround time.

  6. Anti-idiotypic nanobody-alkaline phosphatase fusion proteins: Development of a one-step competitive enzyme immunoassay for fumonisin B{sub 1} detection in cereal

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Mei [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Xu, Yang, E-mail: xuyang@ncu.edu.cn [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Liu, Xing [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); College of Food Science and Technology, Hainan University, No. 58 Renmin Avenue, Haikou 570228 (China); Li, Yanping; He, Qinghua [Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Tu, Zhui [State Key Laboratory of Food Science and Technology, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Fu, Jinheng [Jiangxi-OAI Joint Research Institute, Nanchang University, No. 235 Nanjing East Road, Nanchang 330047 (China); Gee, Shirley J.; Hammock, Bruce D. [Department of Entomology and UCD Comprehensive Cancer Center, University of California, Davis, CA 95616 (United States)

    2016-06-14

    A rapid and sensitive one-step competitive enzyme immunoassay for the detection of FB{sub 1} was developed. The anti-idiotypic nanobody–alkaline phosphatase (Ab2β−Nb−AP) was validated by the AP enzyme activity and the properties of bounding to anti-FB1-mAb (3F11) through colorimetric and chemiluminescence analyses. The 50% inhibitory concentration and the detection limit (LOD) of colorimetric enzyme-linked immunosorbent assay (ELISA) for FB{sub 1} were 2.69 and 0.35 ng mL{sup −1}, respectively, with a linear range of 0.93–7.73 ng mL{sup −1}. The LOD of the chemiluminescence ELISA (CLIA) was 0.12 ng mL{sup −1}, and the IC{sub 50} was 0.89 ± 0.09 ng mL{sup −1} with a linear range of 0.29–2.68 ng mL{sup −1}. Compared with LC-MS/MS, the results of this assay indicated the reliability of the Ab2β−Nb−AP fusion protein based one-step competitive immunoassay for monitoring FB{sub 1} contamination in cereals. The Ab2β−Nb−AP fusion proteins have the potential to replace chemically-coupled probes in competitive enzyme immunoassay systems. - Highlights: • Ab2β−Nb−AP has the potential to replace chemically-coupled probes. • Ab2β−Nb−AP is homogeneous enzyme-labelled antigen can be prepared reproducibly. • We developed a green and rapid one-step competitive enzyme immunoassay. • The sensitivity of one-step CLIA was 9-folds higher than two-step ELISA.

  7. Nanobody Based Immunoassay for Human Soluble Epoxide Hydrolase Detection Using Polymeric Horseradish Peroxidase (PolyHRP) for Signal Enhancement: The Rediscovery of PolyHRP?

    Science.gov (United States)

    Li, Dongyang; Cui, Yongliang; Morisseau, Christophe; Gee, Shirley J; Bever, Candace S; Liu, Xiangjiang; Wu, Jian; Hammock, Bruce D; Ying, Yibin

    2017-06-06

    Soluble epoxide hydrolase (sEH) is a potential pharmacological target for treating hypertension, vascular inflammation, cancer, pain, and multiple cardiovascular related diseases. A variable domain of the heavy chain antibody (termed single domain antibody (sdAb), nanobody, or VHH) possesses the advantages of small size, high stability, ease of genetic manipulation, and ability for continuous manufacture, making such nanobody a superior choice as an immunoreagent. In this work, we developed an ultrasensitive nanobody based immunoassay for human sEH detection using polymeric horseradish peroxidase (PolyHRP) for signal enhancement. Llama nanobodies against human sEH were used as the detection antibody in sandwich enzyme linked immunosorbent assays (ELISA) with polyclonal anti-sEH as the capture antibody. A conventional sandwich ELISA using a horseradish peroxidase (HRP) labeled anti-hemeagglutinin (HA) tag as the tracer showed a marginal sensitivity (0.0015 optical density (OD)·mL/ng) and limit of detection (LOD) of 3.02 ng/mL. However, the introduction of the PolyHRP as the tracer demonstrated a 141-fold increase in the sensitivity (0.21 OD·mL/ng) and 57-fold decrease in LOD (0.05 ng/mL). Systematic comparison of three different tracers in four ELISA formats demonstrated the overwhelming advantage of PolyHRP as a label for nanobody based immunoassay. This enhanced sEH immunoassay was further evaluated in terms of selectivity against other epoxide hydrolases and detection of the target protein in human tissue homogenate samples. Comparison with an enzyme activity based assay and a Western blot for sEH detection reveals good correlation with the immunoassay. This work demonstrates increased competiveness of nanobodies for practical sEH protein detection utilizing PolyHRP. It is worthwhile to rediscover the promising potential of PolyHRP in nanobody and other affinity based methods after its low-profile existence for decades.

  8. Establishment of carcinoembryonic antigen working standard for immunoassay

    International Nuclear Information System (INIS)

    Xu Ligen; Sun Youxiang; Jiao Yan

    2001-01-01

    The author is to prepare the working standard of carcinoembryonic antigen (CEA) for immunoassay and determine its potency. CEA solution of 320 μg/L was prepared from purified CEA solution of 4.6 mg/L and 1% human albumin solution buffered with 50 mmol/L sodium phosphate, pH7.4. This solution was distributed in an aliquot of 0.5 mL (160 ng per ampoule) and lyophilized. The potency of CEA working standard, in terms of present standard of CEA RIA and IRMA kits made by Chinese manufacturers and in terms of 1st IRP CEA HUMAN 73/601 supplied by WHO, has been determined. Mean immunological potency of the working standard is 163 ng per ampoule with confident limit of 159-168 ng per ampoule at 95% probability level. Test of parallelism of dose-response curve for the working standard to that for 1st IRP CEA HUMAN 73/601 has been passed. CEA working standard is suitable to the kits standard for CEA radioimmunoassay and immunoradiometric assay

  9. INNOVATIVE TECHNOLOGICAL SOLUTIONS IN CREATING FUNCTIONAL PRODUCTS POWER

    OpenAIRE

    I. V. Sergienko; A. E. Kutsova; S. V. Kutsov

    2015-01-01

    The article deals with a problem of functional products creation for consumers feeling need in proteins, irreplaceable amino acids, vitamins, mineral substances, food fibers, polynonsaturated fat acids. One of the possible ways to improve human nutrition is using non-traditional cultures for bread making technology containing significant amounts of fibrous substances, easily digestible protein, vitamins, unsaturated fatty acids and minerals. Taking into account the Nutrition Science requireme...

  10. Algorithm for recall of HIV reactive Indian blood donors by sequential immunoassays enables selective donor referral for counseling

    Directory of Open Access Journals (Sweden)

    Thakral B

    2006-01-01

    Full Text Available Background: HIV/AIDS pandemic brought into focus the importance of safe blood donor pool. Aims: To analyze true seroprevalence of HIV infection in our blood donors and devise an algorithm for donor recall avoiding unnecessary referrals to voluntary counseling and testing centre (VCTC. Materials and Methods: 39,784 blood units were screened for anti-HIV 1/2 using ELISA immunoassay (IA-1. Samples which were repeat reactive on IA-1 were further tested using two different immunoassays (IA-2 and IA-3 and Western blot (WB. Based on results of these sequential IAs and WB, an algorithm for recall of true HIV seroreactive blood donors is suggested for countries like India where nucleic acid testing or p24 antigen assays are not mandatory and given the limited resources may not be feasible. Results: The anti-HIV seroreactivity by repeat IA-1, IA-2, IA-3 and WB were 0.16%, 0.11%, 0.098% and 0.07% respectively. Of the 44 IA-1 reactive samples, 95.2% (20/21 of the seroreactive samples by both IA-2 and IA-3 were also WB positive and 100% (6/6 of the non-reactive samples by these IAs were WB negative. IA signal/cutoff ratio was significantly low in biological false reactive donors. WB indeterminate results were largely due to non-specific reactivity to gag protein (p55. Conclusions: HIV seroreactivity by sequential immunoassays (IA-1, IA-2 and IA-3; comparable to WHO Strategy-III prior to donor recall results in decreased referral to VCTC as compared to single IA (WHO Strategy-I being followed currently in India. Moreover, this strategy will repose donor confidence in our blood transfusion services and strengthen voluntary blood donation program.

  11. Fabrication and characterization of tosyl-activated magnetic and nonmagnetic monodisperse microspheres for use in microfluic-based ferritin immunoassay

    Czech Academy of Sciences Publication Activity Database

    Reymond, F.; Vollet, Ch.; Plichta, Zdeněk; Horák, Daniel

    2013-01-01

    Roč. 29, č. 2 (2013), s. 532-542 ISSN 8756-7938 R&D Projects: GA MŠk 7E12053; GA ČR GAP503/10/0664 EU Projects: European Commission(XE) 246513 - NADINE Institutional support: RVO:61389013 Keywords : biosensors * electrochemistry * immunoassays Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.883, year: 2013

  12. FOOD PROCESSING TECHNOLOGY AS A MEDIATOR OF FUNCTIONALITY. STRUCTURE-PROPERTY-PROCESS RELATIONSHIPS

    Directory of Open Access Journals (Sweden)

    Ester Betoret

    2015-02-01

    Full Text Available During the last years, the food industry has been facing technical and economic changes both in society and in the food processing practices, paying high attention to food products that meet the consumers´ demands. In this direction, the study areas in food process and products have evolved mainly from safety to other topics such as quality, environment or health. The improvement of the food products is now directed towards ensuring nutritional and specific functional benefits. Regarding the processes evolution, they are directed to ensure the quality and safety of environmentally friendly food products produced optimizing the use of resources, minimally affecting or even enhancing their nutritional and beneficial characteristics. The product structure both in its raw form and after processing plays an important role maintaining, enhancing and delivering the bioactive compounds in the appropriate target within the organism. The aim of this review is to make an overview on some synergistic technologies that can constitute a technological process to develop functional foods, enhancing the technological and/or nutritional functionality of the food products in which they are applied. More concretely, the effect of homogenization, vacuum impregnation and drying operations on bioactive compounds have been reviewed, focusing on the structure changes produced and its relationship on the product functionality, as well as on the parameters and the strategies used to quantify and increase the achieved functionality.

  13. Total analysis systems with Thermochromic Etching Discs technology.

    Science.gov (United States)

    Avella-Oliver, Miquel; Morais, Sergi; Carrascosa, Javier; Puchades, Rosa; Maquieira, Ángel

    2014-12-16

    A new analytical system based on Thermochromic Etching Discs (TED) technology is presented. TED comprises a number of attractive features such as track independency, selective irradiation, a high power laser, and the capability to create useful assay platforms. The analytical versatility of this tool opens up a wide range of possibilities to design new compact disc-based total analysis systems applicable in chemistry and life sciences. In this paper, TED analytical implementation is described and discussed, and their analytical potential is supported by several applications. Microarray immunoassay, immunofiltration assay, solution measurement, and cell culture approaches are herein addressed in order to demonstrate the practical capacity of this system. The analytical usefulness of TED technology is herein demonstrated, describing how to exploit this tool for developing truly integrated analytical systems that provide solutions within the point of care framework.

  14. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    OpenAIRE

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of th...

  15. Abbott’s Fluorescence Polarization Immunoassay for Cyclosporine and Metabolites Compared with the Sandoz “Sandimmune” RIA

    OpenAIRE

    Sanghvi, Ajit; Diven, Warren; Seltman, Howard; Starzl, Thomas

    1988-01-01

    A new procedure for measuring cyclosporine in plasma has been introduced by Abbott Laboratories, involving their TDx instrumentation and fluorescence polarization immunoassay. Radioimmunoassay (RIA) and high-performance liquid chromatography are currently the conventional methods for measuring cyclosporine in plasma and whole blood. In an effort to find a method that will decrease the radioactive hazard, the reagent and supply cost, and the labor requirements associated with RIA procedures, w...

  16. Part-per-trillion level detection of estradiol by competitive fluorescence immunoassay using DNA/dye conjugate as antibody multiple labels.

    Science.gov (United States)

    Zhu, Shengchao; Zhang, Qin; Guo, Liang-Hong

    2008-08-22

    Fluorescent organic dyes are currently the standard signal-generating labels used in microarray quantification. However, new labeling strategies are needed to meet the demand for high sensitivity in the detection of low-abundance proteins and small molecules. In this report, a long-chain DNA/dye conjugate was used to attach multiple fluorescence labels on antibodies to improve signal intensity and immunoassay sensitivity. Compared with the 30 base-pair (bp) oligonucleotide used in our previous work [Q. Zhang, L.-H. Guo, Bioconjugate Chem. 18 (2007) 1668-1672], conjugation of a 219 bp DNA in solution with a fluorescent DNA binder SYBR Green I resulted in more than sixfold increase in signal intensity, consistent with the increase in bp number. In a direct immunoassay for the detection of goat anti-mouse IgG in a mouse IgG-coated 96-well plate, the long DNA conjugate label also produced higher fluorescence than the short one, accompanied by about 15-fold improvement in the detection limit. To demonstrate its advantage in real applications, the DNA/dye conjugate was employed in the competitive immunoassay of 17beta-estradiol, a clinically and environmentally important analyte. The biotin-terminated DNA was attached to biotinylated anti-estradiol antibody through the biotin/streptavidin/biotin bridge after the immuno-reaction was completed, followed by conjugation with SYBR Green I. The limit of detection for 17beta-estradiol is 1.9 pg mL(-1), which is 200-fold lower than the assay using fluorescein-labeled antibodies. The new multiple labeling strategy uses readily available reagents, and is also compatible with current biochip platform. It has great potential in the sensitive detection of protein and antibody microarrays.

  17. A reactor/separator device for use in automated solid phase immunoassay

    International Nuclear Information System (INIS)

    Farina, P.R.; Ordonez, K.P.; Siewers, I.J.

    1979-01-01

    A reactor/separator device is described for use in automated solid phase immunoassay, including radioimmunoassays. The device is a column fitted at the bottom portion with a water impermeable disc which can hold, for example, immunoabsorbents, immobilized antisera or ion exchange resins. When the contents of the column supported by the disc are brought into contact with an aqueous phase containing reagents or reactants, a chemical reaction is initiated. After the reaction, centrifugally applied pressure forces the aqueous phase through the filter disc making it water permeable and separating a desired component for subsequent analysis. The reactor/separator device of the present invention permits kinetic solid phase assays (non-equilibrium conditions) to be carried out which would be difficult to perform by other conventional methods. (author)

  18. Graphene-based chemiluminescence resonance energy transfer for homogeneous immunoassay.

    Science.gov (United States)

    Lee, Joon Seok; Joung, Hyou-Arm; Kim, Min-Gon; Park, Chan Beum

    2012-04-24

    We report on chemiluminescence resonance energy transfer (CRET) between graphene nanosheets and chemiluminescent donors. In contrast to fluorescence resonance energy transfer, CRET occurs via nonradiative dipole-dipole transfer of energy from a chemiluminescent donor to a suitable acceptor molecule without an external excitation source. We designed a graphene-based CRET platform for homogeneous immunoassay of C-reactive protein (CRP), a key marker for human inflammation and cardiovascular diseases, using a luminol/hydrogen peroxide chemiluminescence (CL) reaction catalyzed by horseradish peroxidase. According to our results, anti-CRP antibody conjugated to graphene nanosheets enabled the capture of CRP at the concentration above 1.6 ng mL(-1). In the CRET platform, graphene played a key role as an energy acceptor, which was more efficient than graphene oxide, while luminol served as a donor to graphene, triggering the CRET phenomenon between luminol and graphene. The graphene-based CRET platform was successfully applied to the detection of CRP in human serum samples in the range observed during acute inflammatory stress.

  19. Synthesis of polycyclic aromatic hydrocarbon-protein conjugates for preparation and immunoassay of antibodies.

    Science.gov (United States)

    Glushkov, Andrey N; Kostyanko, Mikhail V; Cherno, Sergey V; Vasilchenko, Ilya L

    2002-04-01

    The method is described dealing with the synthesis of conjugates protein-polycyclic aromatic hydrocarbons (PAHs), highly soluble in water, stable without special stabilizers and containing the minimum quantity of cross-linked products. The reaction of protein with PAH containing an aldehyde group, has been carried out in an alkaline solution, and stabilization of the conjugate has been achieved by reduction with sodium borohydride in the presence of a compound blocking the formation of an insoluble polymeric fraction. The efficiency of synthesized conjugates for the induction and immunoassay of Abs to PAH for benzo[a]pyrene is shown.

  20. Technology-based functional assessment in early childhood intervention: a pilot study.

    Science.gov (United States)

    Khetani, Mary A; McManus, Beth M; Arestad, Kristen; Richardson, Zachary; Charlifue-Smith, Renee; Rosenberg, Cordelia; Rigau, Briana

    2018-01-01

    Electronic patient-reported outcomes (e-PROs) may provide valid and feasible options for obtaining family input on their child's functioning for care planning and outcome monitoring, but they have not been adopted into early intervention (EI). The purpose of this pilot study was to evaluate the feasibility of implementing technology-based functional assessment into EI practice and to examine child, family, service, and environmental correlates of caregiver-reported child functioning in the home. In a cross-sectional design, eight individual EI providers participated in a 90-min technology-based functional assessment training to recruit participants and a 60-min semi-structured focus group post data collection. Participants completed the Young Children's Participation and Environment Measure (YC-PEM) home section online and Pediatric Evaluation of Disability Inventory Computer Adaptive Test (PEDI-CAT) via iPad. Participants' EI service use data were obtained from administrative records. A total of 37 caregivers of children between 6 and 35 months old (mean age = 19.4, SD = 7.7) enrolled, a rate of 44% (37/84) in 2.5 months. Providers suggested expanding staff training, gathering data during scheduled evaluations, and providing caregivers and providers with access to assessment summaries. Caregivers wanted their child's participation to change in 56% of home activities. Lower caregiver education and higher EI intensity were related to less child involvement in home activities. Implementing technology-based functional assessment is feasible with modifications, and these data can be useful for highlighting child, family, and EI service correlates of caregiver-reported child functioning that merit further study. Feasibility results informed protocol modifications related to EI provider training, timing of data collection, and management of EI service use data extraction, as preparation for a subsequent scale-up study that is underway.

  1. Vertical microreactor stack consist of poly-(tetrafluoroethylene) microfluidics for immunoassay

    International Nuclear Information System (INIS)

    Ukita, Yoshiaki; Kondo, Saki; Utsumi, Yuichi; Takeo, Masahiro; Negoro, Seiji; Kataoka, Chiwa

    2010-01-01

    This paper reports the first application of high-aspect ratio PTFE microstruscute, which fabricated by synchrotron radiation induced photo-evaporation process, to enzyme-linked immunosorvent assay. The advantages of PTFE microstructure for the development of lab-on-a-chip due to the extremely high-aspect ratio microstructure and chemical stability of PTFE is discussed. The results of immunoassay shows the successful detection of analyte (mouse IgG) with detection range with 0-100ng/ml. This result suggests the successful immobilization of antibody (anti-mouse IgG goat antibody) onto the x-ray exposed surface of PTFE microstructure and successful demonstration of antigen-antibody reaction in the PTFE high-aspect ratio microstructure. We also demonstrated the detection of polychlorinated biphenyl (PCB). As the result of demonstration, we successfully detected PCB with ranging analyte concentration of 0.1-10 ng/ml. (author)

  2. Functional and technological properties of camel milk proteins: a review

    DEFF Research Database (Denmark)

    Hailu, Yonas; Hansen, Egon Bech; Seifu, Eyassu

    2016-01-01

    This review summarises current knowledge on camel milk proteins, with focus on significant peculiarities in protein composition and molecular properties. Camel milk is traditionally consumed as a fresh or naturally fermented product. Within the last couple of years, an increasing quantity is being...... processed in dairy plants, and a number of consumer products have been marketed. A better understanding of the technological and functional properties, as required for product improvement, has been gained in the past years. Absence of the whey protein β-LG and a low proportion of к-casein cause differences...... in relation to dairy processing. In addition to the technological properties, there are also implications for human nutrition and camel milk proteins are of interest for applications in infant foods, for food preservation and in functional foods. Proposed health benefits include inhibition of the angiotensin...

  3. Evaluation of envelope glycoprotein E(rns) of an atypical bovine pestivirus as antigen in a microsphere immunoassay for the detection of antibodies against bovine viral diarrhea virus 1 and atypical bovine pestivirus.

    Science.gov (United States)

    Vijayaraghavan, Balaje; Xia, Hongyan; Harimoorthy, Rajiv; Liu, Lihong; Belák, Sándor

    2012-11-01

    Atypical bovine pestiviruses are related antigenically and phylogenetically to bovine viral diarrhea viruses (BVDV-1 and BVDV-2), and may cause the same clinical manifestations in animals. Glycoprotein E(rns) of an atypical bovine pestivirus Th/04_KhonKaen was produced in a baculovirus expression system and was purified by affinity chromatography. The recombinant E(rns) protein was used as an antigen in a microsphere immunoassay for the detection of antibodies against BVDV-1 and atypical bovine pestivirus. The diagnostic performance of the new method was evaluated by testing a total of 596 serum samples, and the assay was compared with enzyme-linked immunosorbent assay (ELISA). Based on the negative/positive cut-off median fluorescence intensity (MFI) value of 2800, the microsphere immunoassay had a sensitivity of 100% and specificity of 100% compared to ELISA. The immunoassay was able to detect antibodies against both BVDV-1 and the atypical pestivirus. This novel microsphere immunoassay has the potential to be multiplexed for simultaneous detection of antibodies against different bovine pathogens in a high-throughput and economical way. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Hapten design and indirect competitive immunoassay for parathion determination: Correlation with molecular modeling and principal component analysis

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yihua [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Jin Maojun [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Gui Wenjun [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Cheng Jingli [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Guo Yirong [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China); Zhu Guonian [Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou 310029 (China)]. E-mail: zhugn@zju.edu.cn

    2007-05-22

    A novel procedure for parathion hapten design is described. The optimal antigen for parathion was selected after molecular modeling studies of six types of potentially immunizing haptens with the aim to identify the best mimicking target analyte. Heterologous competitive indirect enzyme-linked immunosorbent assay (ELISA) was developed after screening a battery of competitors as coating antigens. The relationship between the heterology degree of the competitor and the resulting immunoassay detectability was investigated according to the electronic similarities of the competitor haptens and the target analyte. Molecular modeling and principal component analysis were performed to understand the electronic distribution and steric parameters of the haptens at their minimum energetic levels. The results suggested that the competitors should have a high heterology to produce assays with good detectability values. An indirect competitive ELISA was finally selected for further investigation. The immunoassay had an IC{sub 50} value of 4.79 ng mL{sup -1} and a limit of detection of 0.31 ng mL{sup -1}. There was little or no cross-reactivity to similar compounds tested except for the insecticide parathion-methyl, which showed a cross-reactivity of 7.8%.

  5. Measurement and monitoring technologies are important SITE program component

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    An ongoing component of the Superfund Innovative Technologies Evaluation (SITE) Program, managed by the US EPA at its Hazardous Waste Engineering Research Laboratory in Cincinnati, is the development and demonstration of new and innovative measurement and monitoring technologies that will be applicable to Superfund site characterization. There are four important roles for monitoring and measurement technologies at Superfund sites: (1) to assess the extent of contamination at a site, (2) to supply data and information to determine impacts to human health and the environment, (3) to supply data to select the appropriate remedial action, and (4) to monitor the success or effectiveness of the selected remedy. The Environmental Monitoring Systems Laboratory in Las Vegas, Nevada (EMSL-LV) has been supporting the development of improved measurement and monitoring techniques in conjunction with the SITE Program with a focus on two areas: Immunoassay for toxic substances and fiber optic sensing for in-situ analysis at Superfund sites

  6. Synthesis of CdTe/CdS/ZnS quantum dots and their application in imaging of hepatocellular carcinoma cells and immunoassay for alpha fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Tian Jianniao; Liu Rongjun; Zhao Yanchun; Peng Yan; Hong Xue; Zhao Shulin [Key Laboratory for the Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), College of Chemistry and Chemical Engineering of Guangxi Normal University, Guilin 541004 (China); Xu Qing, E-mail: tianjn58@yahoo.com.cn [Pharmacology Department of Guilin Medical College, Guilin 541004 (China)

    2010-07-30

    We report the imaging of hepatocellular carcinoma cells and the immunoassay for alpha fetoprotein (AFP) using CdTe/CdS/ZnS core-shell-shell QDs. Stable and high PLQY (20%-48%) CdTe/CdS/ZnS core-shell-shell QDs were synthesized by a stepwise process. Bioconjugation of the core-shell-shell QDs with streptavidin (SA) was successfully applied in immunofluorescent imaging of the human hepatocellular carcinoma (HCC) cell line HepG2.2.15. Furthermore, the thioglycolic acid (TGA)-capped CdTe/CdS/ZnS core-shell-shell QDs fluorescence lifetime is longer than fluorescein, so it was first engaged to conjugate with antigen for the determination of protein (AFP) by fluorescence polarization immunoassay.

  7. Synthesis of CdTe/CdS/ZnS quantum dots and their application in imaging of hepatocellular carcinoma cells and immunoassay for alpha fetoprotein

    International Nuclear Information System (INIS)

    Tian Jianniao; Liu Rongjun; Zhao Yanchun; Peng Yan; Hong Xue; Zhao Shulin; Xu Qing

    2010-01-01

    We report the imaging of hepatocellular carcinoma cells and the immunoassay for alpha fetoprotein (AFP) using CdTe/CdS/ZnS core-shell-shell QDs. Stable and high PLQY (20%-48%) CdTe/CdS/ZnS core-shell-shell QDs were synthesized by a stepwise process. Bioconjugation of the core-shell-shell QDs with streptavidin (SA) was successfully applied in immunofluorescent imaging of the human hepatocellular carcinoma (HCC) cell line HepG2.2.15. Furthermore, the thioglycolic acid (TGA)-capped CdTe/CdS/ZnS core-shell-shell QDs fluorescence lifetime is longer than fluorescein, so it was first engaged to conjugate with antigen for the determination of protein (AFP) by fluorescence polarization immunoassay.

  8. Nanoparticle-based immunosensors and immunoassays for aflatoxins

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xu; Niessner, Reinhard [Institute of Hydrochemistry and Chair of Analytical Chemistry, Technische Universität München, Marchioninistrasse 17, D-81377 München (Germany); Tang, Dianping [Key Laboratory of Analysis and Detection for Food Safety, MOE & Fujian Province, Department of Chemistry, Fuzhou University, Fuzhou 350108 (China); Knopp, Dietmar, E-mail: dietmar.knopp@ch.tum.de [Institute of Hydrochemistry and Chair of Analytical Chemistry, Technische Universität München, Marchioninistrasse 17, D-81377 München (Germany)

    2016-03-17

    Aflatoxins are naturally existing mycotoxins produced mainly by Aspergillus flavus and Aspergillus parasiticus, present in a wide range of food and feed products. Because of their extremely high toxicity and carcinogenicity, strict control of maximum residue levels of aflatoxins in foodstuff is set by many countries. In daily routine, different chromatographic methods are used almost exclusively. As supplement, in several companies enzyme immunoassay-based sample testing as primary screening is performed. Recently, nanomaterials such as noble metal nanoparticles, magnetic particles, carbon nanomaterials, quantum dots, and silica nanomaterials are increasingly utilized for aflatoxin determination to improve the sensitivity and simplify the detection. They are employed either as supports for the immobilization of biomolecules or as electroactive or optical labels for signal transduction and amplification. Several nanoparticle-based electrochemical, piezoelectric, optical, and immunodipstick assays for aflatoxins have been developed. In this review, we summarize these recent advances and illustrate novel concepts and promising applications in the field of food safety. - Highlights: • Novel concepts and promising applications of nanoparticle-based immunological methods for the determination of aflatoxins. • Inclusion of most important nanomaterials and hybrid nanostructures. • Inclusion of electrochemical, optical and mass-sensitive biosensors as well as optical and immunochromatographic assays.

  9. Radio-immunoassay of plasma arginine vasopressin in man. Comparison of two methods of extraction

    International Nuclear Information System (INIS)

    Wolf, J.P.; Dumoulin, G.; Henriet, M.T.; Baulay, A.; Berthelay, S.

    1987-01-01

    Two methods of extraction, prior to radio-immunoassay (RIA) of human plasma arginine vasopressin (AVP) were tested: ethanol extraction (ETH), chromatography with ODS-Silice (ODS-Sil). Recovery of 125 I AVP was higher when using ODS-Sil than when using ETH. Recovery of standard AVP was found to be more efficient and reproducible for ODS-Sil. However, the RIA used, performed after chromatography with ODS-Sil, is not enough sensitive to detect low concentrations but is able to detect high concentrations and physiological variations of plasma AVP [fr

  10. System-on-fluidics immunoassay device integrating wireless radio-frequency-identification sensor chips.

    Science.gov (United States)

    Yazawa, Yoshiaki; Oonishi, Tadashi; Watanabe, Kazuki; Shiratori, Akiko; Funaoka, Sohei; Fukushima, Masao

    2014-09-01

    A simple and sensitive point-of-care-test (POCT) device for chemiluminescence (CL) immunoassay was devised and tested. The device consists of a plastic flow-channel reactor and two wireless-communication sensor chips, namely, a photo-sensor chip and a temperature-sensor chip. In the flow-channel reactor, a target antigen is captured by an antibody immobilized on the inner wall of the flow-channel and detected with enzyme labeled antibody by using CL substrate. The CL signal corresponding to the amount of antigen is measured by a newly developed radio-frequency-identification (RFID) sensor, which enables batteryless operation and wireless data communication with an external reader. As for the POCT device, its usage environment, especially temperature, varies for each measurement. Hence, temperature compensation is a key issue in regard to eliminating dark-signal fluctuation, which is a major factor in deterioration of the precision of the POCT device. A two-stage temperature-compensation scheme was adopted. As for the first stage, the signals of two photodiodes, one with an open window and one with a sealed window, integrated on the photo-sensor chip are differentiated to delete the dark signal. As for the second stage, the differentiated signal fluctuation caused by a temperature variation is compensated by using the other sensor chip (equipped with a temperature sensor). The dark-level fluctuation caused by temperature was reduced from 0.24 to 0.02 pA/°C. The POCT device was evaluated as a CL immunoassay of thyroid-stimulating hormone (TSH). The flow rate of the CL reagent in the flow channel was optimized. As a result, the detection limit of the POCT device was 0.08 ng/ml (i.e., 0.4 μIU/ml). Copyright © 2014 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  11. A versatile SERS-based immunoassay for immunoglobulin detection using antigen-coated gold nanoparticles and malachite green-conjugated protein A/G

    Science.gov (United States)

    A surface enhanced Raman scattering (SERS) immunoassay for antibody detection in serum is described in the present work. The developed assay is conducted in solution and utilizes Au nanoparticles coated with the envelope (E) protein of West Nile Virus (WNV) as the SERS-active substrate and malachite...

  12. Quantitation of estrogen receptor in seventy-five specimens of breast cancer: comparison between an immunoassay (Abbott ER-EIA monoclonal) and a [3H]estradiol binding assay based on isoelectric focusing in polyacrylamide gel

    International Nuclear Information System (INIS)

    Pousette, A.; Gustafsson, S.A.; Thoernblad, A.M.N.; Nordgren, A.; Saellstroem, J.Li.; Lindgren, A.; Sundelin, P.; Gustafsson, J.A.

    1986-01-01

    Quantitation of estrogen receptor has been performed in cytosol prepared from 75 specimens of breast cancer tissue from patients who had not received hormonal therapy. The study was performed in order to compare an immunoassay (Abbott Laboratories, North Chicago, IL) with our currently used method for estrogen receptor analysis based on isoelectric focusing of [ 3 H]estradiol-receptor complex in polyacrylamide gels. Using linear regression analysis, a regression coefficient (slope) of 1.30 and a correlation coefficient of 0.75 were calculated. The differences in results between the two methods are probably partly explained by the fact that the ligand-based method only measures unoccupied receptor, whereas the immunoassay detects the total amount of receptor, resulting in generally slightly higher concentrations with the latter method. However, in five of 75 specimens the ligand-based method gave a considerably higher concentration of estrogen receptor. This was most probably explained by partial proteolysis resulting in the formation of receptor fragment(s), which was undetectable with the immunoassay but detectable with the ligand-based method. These observations underline the importance of careful handling of specimens during the whole immunoassay procedure

  13. Design of a single-step immunoassay principle based on the combination of an enzyme-labeled antibody release coating and a hydrogel copolymerized with a fluorescent enzyme substrate in a microfluidic capillary device.

    Science.gov (United States)

    Wakayama, Hideki; Henares, Terence G; Jigawa, Kaede; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki

    2013-11-21

    A combination of an enzyme-labeled antibody release coating and a novel fluorescent enzyme substrate-copolymerized hydrogel in a microchannel for a single-step, no-wash microfluidic immunoassay is demonstrated. This hydrogel discriminates the free enzyme-conjugated antibody from an antigen-enzyme-conjugated antibody immunocomplex based on the difference in molecular size. A selective and sensitive immunoassay, with 10-1000 ng mL(-1) linear range, is reported.

  14. Design of a surface plasmon resonance immunoassay for therapeutic drug monitoring of amikacin.

    Science.gov (United States)

    Losoya-Leal, Adrian; Estevez, M-Carmen; Martínez-Chapa, Sergio O; Lechuga, Laura M

    2015-08-15

    The therapeutic drug monitoring (TDM) of pharmaceutical drugs with narrow therapeutic ranges is of great importance in the clinical setting. It provides useful information towards the enhancement of drug therapies, aiding in dosage control and toxicity risk management. Amikacin is an aminoglycoside antibiotic commonly used in neonatal therapies that is indicated for TDM due to the toxicity risks inherent in its use. Current techniques for TDM such as high performance liquid chromatography (HPLC) and gas chromatography-mass spectrometry (GC-MS) are costly, time consuming, and cannot be performed at the site of action. Over the last decades, surface plasmon resonance (SPR) biosensors have become increasingly popular in clinical diagnostics due to their ability to detect biomolecular interactions in real-time. We present an SPR-based competitive immunoassay for the detection of the antibiotic amikacin, suitable for TDM in both adults and neonates. We have obtained high specificity and sensitivity levels with an IC50 value of 1.4ng/mL and a limit of detection of 0.13ng/mL, which comfortably comply with the drug's therapeutic range. Simple dilution of serum can therefore be sufficient to analyze low-volume real samples from neonates, increasing the potential of the methodology for TDM. Compared to current TDM conventional methods, this SPR-based immunoassay can provide advantages such as simplicity, potential portability, and label-free measurements with the possibility of high throughput. This work is the foundation towards the development of an integrated, simple use, highly sensitive, fast, and point-of-care sensing platform for the opportune TDM of antibiotics and other drugs in a clinical setting. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Development and validation of a direct sandwich chemiluminescence immunoassay for measuring DNA adducts of benzo[a]pyrene and other polycyclic aromatic hydrocarbons

    DEFF Research Database (Denmark)

    Georgiadis, Panagiotis; Kovács, Katalin; Kaila, Stella

    2012-01-01

    We have developed and validated a sandwich chemiluminescence immunoassay (SCIA) which measures polycyclic aromatic hydrocarbon (PAH)-DNA adducts combining high throughput and adequate sensitivity, appropriate for evaluation of adduct levels in human population studies. Fragmented DNA is incubated...

  16. Rapid bead-based immunoassay for measurement of mannose-binding lectin

    DEFF Research Database (Denmark)

    Bay, J T; Garred, P

    2009-01-01

    have been developed more automated platforms for MBL analysis is urgently needed. To pursue this, we set out to develop a flexible bead-based MBL immunoassay. Serum was obtained from 98 healthy individuals and 50 patients investigated for possible immunodeficiencies. We used the Luminex xMAP bead array...... coefficient were found be 7.88% and 5.70%, respectively. A close correlation between the new assay and a reference MBL measurement ELISA was found (rho 0.9381, P bead-based assay was less sensitive to interfering anti-murine antibodies in the blood samples than when the antibodies employed were...... used in the reference polystyrene-based ELISA. The new assay could be performed in 3 h with less than 25 microl serum required of each sample. These results show that MBL can be measured readily using a bead-based platform, which may form an efficient basis for a multiplex approach to measure different...

  17. FUNCTIONING FEATURES OF COMPUTER TECHNOLOGY WHILE FORMING PRIMARY SCHOOLCHILDREN’S COMMUNICATIVE COMPETENCE

    Directory of Open Access Journals (Sweden)

    Olena Beskorsa

    2017-04-01

    Full Text Available The article reveals the problem of functioning features of computer technology while forming primary schoolchildren’s communicative competence whose relevance is proved by the increasing role of a foreign language as a means of communication and modernization of foreign language education. There is a great deal of publications devoted to the issue of foreign language learning at primary school by N. Biriukevych, O. Kolominova, O. Metolkina, O. Petrenko, V. Redko, S. Roman. Implementing of innovative technology as well as computer one is to intensify the language learning process and to improve young learners’ communicative skills. The aim of the article is to identify computer technology functioning features while forming primary schoolchildren communicative competence. In this study we follow the definition of the computer technology as an information technology whose implementation may be accompanied with a computer as one of the tools, excluding the use of audio and video equipment, projectors and other technical tools. Using computer technologies is realized due to a number of tools which are divided into two main groups: electronic learning materials; computer testing software. The analysis of current textbooks and learning and methodological complexes shows that teachers prefer authentic electronic materials to the national ones. The most available English learning materials are on the Internet and they are free. The author of the article discloses several on-line English learning tools and depict the opportunities to use them while forming primary schoolchildren’s communicative competence. Special attention is also paid to multimedia technology, its functioning features and multimedia lesson structure. Computer testing software provides tools for current and control assessing results of mastering language material, communicative skills, and self-assessing in an interactive way. For making tests for assessing English skill

  18. Faraday cage-type electrochemiluminescence immunosensor for ultrasensitive detection of Vibrio vulnificus based on multi-functionalized graphene oxide.

    Science.gov (United States)

    Guo, Zhiyong; Sha, Yuhong; Hu, Yufang; Yu, Zhongqing; Tao, Yingying; Wu, Yanjie; Zeng, Min; Wang, Sui; Li, Xing; Zhou, Jun; Su, Xiurong

    2016-10-01

    A novel Faraday cage-type electrochemiluminescence (ECL) immunosensor devoted to the detection of Vibrio vulnificus (VV) was fabricated. The sensing strategy was presented by a unique Faraday cage-type immunocomplex based on immunomagnetic beads (IMBs) and multi-functionalized graphene oxide (GO) labeled with (2,2'-bipyridine)(5-aminophenanthroline)ruthenium (Ru-NH2). The multi-functionalized GO could sit on the electrode surface directly due to the large surface area, abundant functional groups, and good electronic transport property. It ensures that more Ru-NH2 is entirely caged and become "effective," thus improving sensitivity significantly, which resembles extending the outer Helmholtz plane (OHP) of the electrode. Under optimal conditions, the developed immunosensor achieves a limit of detection as low as 1 CFU/mL. Additionally, the proposed immunosensor with high sensitivity and selectivity can be used for the detection of real samples. The novel Faraday cage-type method has shown potential application for the diagnosis of VV and opens up a new avenue in ECL immunoassay. Graphical abstract Faraday cage-type immunoassay mode for ultrasensitive detection by extending OHP.

  19. Functional evolution and accumulation of technological innovation systems: the case of renewable energy in East Africa

    NARCIS (Netherlands)

    Tigabu, A.D.; Berkhout, F.G.H.; van Beukering, P.J.H.

    2015-01-01

    This paper compares the historical development of innovation systems related to biogas and improved cooking stove technologies in Rwanda and Kenya by applying the 'functions approach'. It argues that the accumulation of functions in these four renewable energy technological innovation systems (TISs)

  20. Rapid extraction and quantitative detection of the herbicide diuron in surface water by a hapten-functionalized carbon nanotubes based electrochemical analyzer.

    Science.gov (United States)

    Sharma, Priyanka; Bhalla, Vijayender; Tuteja, Satish; Kukkar, Manil; Suri, C Raman

    2012-05-21

    A solid phase extraction micro-cartridge containing a non-polar polystyrene absorbent matrix was coupled with an electrochemical immunoassay analyzer (EIA) and used for the ultra-sensitive detection of the phenyl urea herbicide diuron in real samples. The EIA was fabricated by using carboxylated carbon nanotubes (CNTs) functionalized with a hapten molecule (an amine functionalized diuron derivative). Screen printed electrodes (SPE) were modified with these haptenized CNTs and specific in-house generated anti diuron antibodies were used for bio-interface development. The immunodetection was realized in a competitive electrochemical immunoassay format using alkaline phosphatase labeled secondary anti-IgG antibody. The addition of 1-naphthyl phosphate substrate resulted in the production of an electrochemically active product, 1-naphthol, which was monitored by using differential pulse voltammetry (DPV). The assay exhibited excellent sensitivity and specificity having a dynamic response range of 0.01 pg mL(-1) to 10 μg mL(-1) for diuron with a limit of detection of around 0.1 pg mL(-1) (n = 3) in standard water samples. The micro-cartridge coupled hapten-CNTs modified SPE provided an effective and efficient electrochemical immunoassay for the real-time monitoring of pesticides samples with a very high degree of sensitivity.

  1. Dog cloning with in vivo matured oocytes obtained using electric chemiluminescence immunoassay-predicted ovulation method.

    Science.gov (United States)

    Lee, Seunghoon; Zhao, Minghui; No, Jingu; Nam, Yoonseok; Im, Gi-Sun; Hur, Tai-Young

    2017-01-01

    Radioactive immunoassay (RIA) is a traditional serum hormone assay method, but the application of the method in reproductive studies is limited by the associated radioactivity. The aim of present study was to evaluate the reliability of RIA and to compare its canine serum progesterone concentration determination accuracy to that of the electric chemiluminescence immunoassay (ECLI). In vivo matured oocytes were utilized for canine somatic cell nuclear transfer (SCNT), and serum progesterone levels were assessed to accurately determine ovulation and oocyte maturation. Canine serum progesterone concentrations during both proestrus and estrus were analyzed by RIA and ECLI to determine the ovulation day. Although both methods detected similar progesterone levels before ovulation, the mean progesterone concentration determined using ECLI was significantly higher than of RIA three days before ovulation. Following ovulation, oocytes were collected by surgery, and a lower percentage of mature oocytes were observed using ECLI (39%) as compared to RIA (67%) if 4-8ng/ml of progesterone were used for determination of ovulation. A high percentage of mature oocytes was observed using ECLI when 6-15 ng/mL of progesterone was used for ovulation determination. To determine whether ECLI could be used for canine cloning, six canines were selected as oocyte donors, and two puppies were obtained after SCNT and embryo transfer. In conclusion, compared to the traditional RIA method, the ECLI method is a safe and reliable method for canine cloning.

  2. The influence of intravenous canrenoate on the determination of digoxin in serum by radio- and enzyme-immunoassay

    International Nuclear Information System (INIS)

    Rietbrock, N.; Lichey, J.; Borner, K.; Freie Univ. Berlin

    1979-01-01

    Ten patients were kept on a constant maintenance dose of digoxin. During a baseline period of 6 days, blood samples were taken daily for analysis of digoxin in serum. On the 6th day the maintenance dose of digoxin was withheld and a single intravenous dose of 200mg potassium-canrenoate (AldactoneR) was administered to all patients. Digoxin in serum was determined by a classical radioimmunoassay with 125 I-digoxin and solid phase technique (RIA-NEN) and partly by a heterogenous enzyme-immunoassay (EnzymunR-Digoxin, Boehringer, Mannheim). Results of the radioimmunoassay indicated a rise of apparent serum digoxin levels with an average maximum of 201% of the mean baseline value 30 min after injection of canrenoate and a gradual return to the baseline value within 6 to 10 hours. Contrary to the radioimmunoassay there was no interference when using the enzyme-immunoassay in a subgroup of identical serum samples: serum digoxin levels remained constant throughout the test. Interference of determinations of digoxin in serum by spironolactone and its metabolites appear to be related to two factors: 1. The mode of administration and the amount of interfering drug, 2. the specifity of the digoxin antibody used in the kit. (orig.) [de

  3. COMPARISON OF IMMUNOASSAY AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY METHODS FOR MEASURING 3,5,6-TRICHLORO-2PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    Science.gov (United States)

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by a commercial RaPID immunoassay testing kit. ...

  4. Composite poly(methyl methacrylate-methacrylic acid-2-hydroxyethyl methacrylate) latex for immunoassay. The case of plasminogen.

    Science.gov (United States)

    Miksa, B; Wilczynska, M; Cierniewski, C; Basinska, T; Slomkowski, S

    1995-01-01

    Poly(methyl methacrylate-methacrylic acid-2-hydroxyethyl methacrylate) latex (ACRYLAT) was synthesized by radical precipitation polymerization. The mass median diameter (MMD) and the geometrical standard deviation (GSD) of the ACRYLAT particles were 138 nm and 1.2, respectively. The concentration of the titrable carboxylic groups in the surface layer of latex particles was equal to 8.41 x 10(-6) mol m-2. Latex was able to bind up to 2.82 x 10(-7) mol of 1-aminopyrene per 1 m2 of the surface of the latex particles due to the ionic interactions between carboxylate anions and ammonium cations of protonated 1-aminopyrene. ACRYLAT was able to immobilize covalently human serum albumin in amounts up to 0.23 mg m-2. Aggregation of ACRYLAT with immobilized HSA, induced with specific antibodies (anti-HSA), was investigated turbidimetrically. The results indicated that in the model turbidimetric immunoassay, ACRYLAT coated with HSA can be used for the detection of anti-HSA in the goat anti-HSA serum diluted from 50 to 7000-fold. Immobilization of rabbit antibodies to plasminogen (anti-Plg) to ACRYLAT via the epsilon-aminocaproic acid linkers provided particles which were used for the development of the turbidimetric immunoassay for plasminogen. In this assay plasminogen could be detected in concentration ranging from 0.75 to 75 micrograms ml-1 in the blood plasma.

  5. The microassay on a card: A rugged, portable immunoassay

    Science.gov (United States)

    Kidwell, David

    1991-01-01

    The Microassay on a Card (MAC) is a portable, hand-held, non-instrumental immunoassay that can test for the presence of a wide variety of substances in the environment. The MAC is a simple device to use. A drop of test solution is placed on one side of the card and within five minutes a color is developed on the other side in proportion to the amount of substance in the test solution, with sensitivity approaching 10 ng/ml. The MAC is self-contained and self-timed; no reagents or timing is necessary. The MAC may be configured with multiple wells to provide simultaneous testing for multiple species. As envisioned, the MAC will be employed first as an on-site screen for drugs of abuse in urine or saliva. If the MAC can be used as a screen of saliva for drugs of abuse, it could be applied to driving while intoxicated, use of drugs on the job, or testing of the identity of seized materials. With appropriate modifications, the MAC also could be used to test for environmental toxins or pollutants.

  6. Time-Resolved Fluorescence Immunoassay for C-Reactive Protein Using Colloidal Semiconducting Nanoparticles

    Directory of Open Access Journals (Sweden)

    Pekka Hänninen

    2011-11-01

    Full Text Available Besides the typical short-lived fluorescence with decay times in the nanosecond range, colloidal II/VI semiconductor nanoparticles dispersed in buffer also possess a long-lived fluorescence component with decay times in the microsecond range. Here, the signal intensity of the long-lived luminescence at microsecond range is shown to increase 1,000-fold for CdTe nanoparticles in PBS buffer. This long-lived fluorescence can be conveniently employed for time-gated fluorescence detection, which allows for improved signal-to-noise ratio and thus the use of low concentrations of nanoparticles. The detection principle is demonstrated with a time-resolved fluorescence immunoassay for the detection of C-reactive protein (CRP using CdSe-ZnS nanoparticles and green light excitation.

  7. Specific T-cell epitopes for immunoassay-based diagnosis of Mycobacterium tuberculosis infection

    DEFF Research Database (Denmark)

    Brock, I; Weldingh, K; Leyten, EM

    2004-01-01

    Specific T-cell epitopes for immunoassay-based diagnosis of Mycobacterium tuberculosis infection.Brock I, Weldingh K, Leyten EM, Arend SM, Ravn P, Andersen P. Department of Infectious Disease Immunology, Statens Serum Institute, Artillerivej 5, DK-2300 Copenhagen S, Denmark. The currently used...... method for immunological detection of tuberculosis infection, the tuberculin skin test, has low specificity. Antigens specific for Mycobacterium tuberculosis to replace purified protein derivative are therefore urgently needed. We have performed a rigorous assessment of the diagnostic potential of four...... selected and combined the specific peptide stretches from the four proteins not recognized by M. bovis BCG-vaccinated individuals. These peptide stretches were tested with peripheral blood mononuclear cells obtained from patients with microscopy- or culture-confirmed tuberculosis and from healthy M. bovis...

  8. Fieldable, real-time enzyme immunoassay kits for drugs on surfaces

    Science.gov (United States)

    Chiappini, Michele W.; Wendel, Gregory J.; Duquette, Peter H.; Hamilton, Martha J.; Chudzik, Stephen J.; Chappa, Ralph A.

    1994-03-01

    Immunoassays (e.g., RIA, EIA) have been demonstrated to be useful for rapid, convenient detection and semiquantitative analysis of drugs. Thermedics Detection, Inc. manufactures a rapid, sensitive, self-contained, disposable, EIA device, developed by Bio-Metric Systems, Inc., designed to allow untrained personnel to perform in field situations. This format has been developed for drugs in biological fluids and on surfaces. The analyte in the test sample competes with an enzyme-analyte conjugate for a limited number of immobilized antibody sites. The AccuPRESS Test format can detect analytes at 10 ppb in biological fluids, water, and soil, and on surfaces, such as suitcases, vehicles, tables and hands, with positive results indicated by clearly visible color development within 5 minutes. This format is designed to have all dry components and to have an ambient shelf life of greater than one year. The format is available for cocaine and opiate derivatives, including heroin, and is readily adaptable for use with numerous other drugs, explosives, and environmental pollutants.

  9. [Development and technological transfer of functional pastas extended with legumes].

    Science.gov (United States)

    Granito, Marisela; Ascanio, Vanesa

    2009-03-01

    Development and technological transfer of functional pastas extended with legumes. Semolina pasta is a highly consumed foodstuff, the biological value of which is low because its protein is deficient in lysine. However, if the semolina is extended with legumes rich in this essential aminoacid, not only and aminoacid supplementation is produced, but also the dietary fibre and minerals are increased. In this work, pastas extended in 10% with a white variety of Phaseolus vulgaris and with Cajanus cajan were produced on a pilot plant scale, and this technology was transferred to a cooperative producing artisanal pastas. The cooking qualities and the physical, chemical, and nutritional characteristics of the pastas were evaluated, as well as the sensorial acceptability in institutionalized elderly people. The extension of the pastas with legume flours increased the optimum cooking time (15 to 20%), the weight (20% and 25%), and the loss of solids by cooking. Similarly, the functional value of the pastas increased by increasing the contents of minerals and dietary fibre. The protein content, as well as the protein digestibility in vitro also increased; however, the parameters of colour L, a and b, and the total starch content of the pastas decreased. At consumer level, the pastas extended with legumes had a good acceptability, for what it was concluded that the extension of the semolina with legume flours in the manufacture of pastas is technologically feasible.

  10. Description of a nanobody-based competitive immunoassay to detect tsetse fly exposure.

    Directory of Open Access Journals (Sweden)

    Guy Caljon

    2015-02-01

    Full Text Available Tsetse flies are the main vectors of human and animal African trypanosomes. The Tsal proteins in tsetse fly saliva were previously identified as suitable biomarkers of bite exposure. A new competitive assay was conceived based on nanobody (Nb technology to ameliorate the detection of anti-Tsal antibodies in mammalian hosts.A camelid-derived Nb library was generated against the Glossina morsitans morsitans sialome and exploited to select Tsal specific Nbs. One of the three identified Nb families (family III, TsalNb-05 and TsalNb-11 was found suitable for anti-Tsal antibody detection in a competitive ELISA format. The competitive ELISA was able to detect exposure to a broad range of tsetse species (G. morsitans morsitans, G. pallidipes, G. palpalis gambiensis and G. fuscipes and did not cross-react with the other hematophagous insects (Stomoxys calcitrans and Tabanus yao. Using a collection of plasmas from tsetse-exposed pigs, the new test characteristics were compared with those of the previously described G. m. moristans and rTsal1 indirect ELISAs, revealing equally good specificities (> 95% and positive predictive values (> 98% but higher negative predictive values and hence increased sensitivity (> 95% and accuracy (> 95%.We have developed a highly accurate Nb-based competitive immunoassay to detect specific anti-Tsal antibodies induced by various tsetse fly species in a range of hosts. We propose that this competitive assay provides a simple serological indicator of tsetse fly presence without the requirement of test adaptation to the vertebrate host species. In addition, the use of monoclonal Nbs for antibody detection is innovative and could be applied to other tsetse fly salivary biomarkers in order to achieve a multi-target immunoprofiling of hosts. In addition, this approach could be broadened to other pathogenic organisms for which accurate serological diagnosis remains a bottleneck.

  11. Functional information technology in geometry-graphic training of engineers

    Directory of Open Access Journals (Sweden)

    Irina D. Stolbova

    2017-01-01

    implementation of this model is based on the functional characteristics analysis of the applied technology training. We describe the use of a complex system of information technology in various forms of training. This shows the options for the integration of these technologies in the content of the sections of the students’ graphic training, as well as the efficiency of their use.The materials can be used to optimize the learning process in technical universities both in the graphic training and other subject areas.

  12. Ultrasensitive fluorescence immunoassay for detection of ochratoxin A using catalase-mediated fluorescence quenching of CdTe QDs

    Science.gov (United States)

    Huang, Xiaolin; Zhan, Shengnan; Xu, Hengyi; Meng, Xianwei; Xiong, Yonghua; Chen, Xiaoyuan

    2016-04-01

    Herein, for the first time we report an improved competitive fluorescent enzyme linked immunosorbent assay (ELISA) for the ultrasensitive detection of ochratoxin A (OTA) by using hydrogen peroxide (H2O2)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (QDs). In this immunoassay, catalase (CAT) was labeled with OTA as a competitive antigen to connect the fluorescence signals of the QDs with the concentration of the target. Through the combinatorial use of H2O2-induced fluorescence quenching of CdTe QDs as a fluorescence signal output and the ultrahigh catalytic activity of CAT to H2O2, our proposed method could be used to perform a dynamic linear detection of OTA ranging from 0.05 pg mL-1 to 10 pg mL-1. The half maximal inhibitory concentration was 0.53 pg mL-1 and the limit of detection was 0.05 pg mL-1. These values were approximately 283- and 300-folds lower than those of horseradish peroxidase (HRP)-based conventional ELISA, respectively. The reported method is accurate, highly reproducible, and specific against other mycotoxins in agricultural products as well. In summary, the developed fluorescence immunoassay based on H2O2-induced fluorescence quenching of CdTe QDs can be used for the rapid and highly sensitive detection of mycotoxins or haptens in food safety monitoring.Herein, for the first time we report an improved competitive fluorescent enzyme linked immunosorbent assay (ELISA) for the ultrasensitive detection of ochratoxin A (OTA) by using hydrogen peroxide (H2O2)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (QDs). In this immunoassay, catalase (CAT) was labeled with OTA as a competitive antigen to connect the fluorescence signals of the QDs with the concentration of the target. Through the combinatorial use of H2O2-induced fluorescence quenching of CdTe QDs as a fluorescence signal output and the ultrahigh catalytic activity of CAT to H2O2, our proposed method could be used to

  13. Comparing the innovation effects of support schemes for renewable electricity technologies: A function of innovation approach

    International Nuclear Information System (INIS)

    Río, Pablo del; Bleda, Mercedes

    2012-01-01

    The aim of this paper is to provide a comparative assessment of the innovation effects of instruments which support the diffusion of renewable electricity technologies with a functions-oriented technological innovation system perspective. The paper provides a link between two major streams of the literature: the functions of innovation systems and the literature on renewable electricity support schemes. We show that, when a functional perspective is adopted, feed-in tariffs are likely to be superior to other policy instruments (quotas with tradable green certificates and tendering), although they still need to be complemented with other instruments, most importantly, direct R and D support. Furthermore, those innovation effects are affected by the specific design elements of the instruments chosen. - Highlights: ► A comparison of the innovation effects of instruments for the diffusion of renewable technologies. ► A functions-oriented technological innovation system perspective. ► A link between the functions of innovation systems and the literature on renewable electricity support schemes. ► Feed-in tariffs are likely to be superior to other instruments. ► Innovation effects are affected by the specific design elements of instruments.

  14. Development of an immunoassay for determination of 2,4-dichlorophenoxyacetic acid (2,4-D) based upon the recombinant Fab fragment of 2,4-D specific antibody

    Science.gov (United States)

    Nguyen, Van C.; Nguyen, Thi D. T.; Dau, Hung A.; Tham, Thu N.; Quyen, Dinh T.; Bachmman, Till; Schmid, Rolf D.

    2001-09-01

    To develop an immunoassay and further an immunosensor for 2,4-D based upon recombinant antibody, the Fab fragments of 2,4-D specific antibody were expressed in E. coli. Western blotting analysis of the periplasmic cell fractions shown that under the non-reducing condition only a single protein band at a molecular mass of 45-kDa, corresponding to the whole Fab fragment was detected. Antigen binding activity for 2,4-D was found only in the extract of cells bearing the 2,4-D plasmid. An immunoassay based on the competitive reaction of 2,4-D and enzyme tracer with 2,4-D Fab fragments immobilized on micro titer plates via rabbit anti-mouse IgC was developed. Using this assay, 2,4-D could be detected at concentration range of 0.5 (mu) g/1 to 10(mu) g/1. The center point of the 2,4-D test was found at a concentration of 5 (mu) g/l. The assay was applied for detection of 2,4-D in spiked orange samples, resulting in recovery rate of 90 percent. The immunoassay could be applied to monitor human exposure to 2,4-D from contamination in fruit samples.

  15. Magnetic Particle-Based Immunoassay of Phosphorylated p53 Using Protein-Cage Templated Lead Phosphate and Carbon Nanospheres for Signal Amplification

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Aiqiong; Bao, Yuanwu; Ge, Xiaoxiao; Shin, Yongsoon; Du, Dan; Lin, Yuehe

    2012-11-20

    Phosphorylated p53 at serin 15 (phospho-p53-15) is a potential biomarker of Gamma-radiation exposure. In this paper, we described a new magnetic particles (MPs)-based electrochemical immunoassay of human phospho-p53-15 using carbon nanospheres (CNS) and protein-cage templated lead phosphate nanoparticles for signal amplification. Greatly enhanced sensitivity was achieved by three aspects: 1) The protein-cage nanoparticle (PCN) and p53-15 signal antibody (p53-15 Ab2) are linked to CNS (PCNof each apoferritin; 3) MPs capture a large amount of primary antibodies. Using apoferritin templated metallic phosphate instead of enzyme as label has the advantage of eliminating the addition of mediator or immunoreagents and thus makes the immunoassay system simpler. The subsequent stripping voltammetric analysis of the released lead ions were detected on a disposable screen printed electrode. The response current was proportional to the phospho-p53-15 concentration in the range of 0.02 to 20 ng mL-1 with detection limit of 0.01 ng mL-1. This method shows a good stability, reproducibility and recovery.

  16. Comparison of conventional culture methods and two commercial enzyme immunoassays for detection of Salmonella in porcine fecal samples and cecal contents

    DEFF Research Database (Denmark)

    Wegener, Henrik Caspar; Baggesen, Dorte Lau

    1997-01-01

    Two commercial enzyme immunoassays, designated EIA-1 and EIA-2, for the detection of salmonella in feces and cecal contents were compared to conventional culture methods. Out of 362 cecal content samples, 35 were positive by EIA-1 and 30 were positive by EIA-2 and conventional methods. Out of 189...

  17. Enzyme immunoassay for DDT analysis in Lebanese soils

    International Nuclear Information System (INIS)

    Bashour, I.; Dagher, S.; Shammas, G.; Sukkariyah, B.; Kawar, N.

    2000-01-01

    Full text: The use of enzyme-linked immunosorbent assay (ELISA) technique in estimating pesticide residue in soils is a faster, less expensive and easier method to use than the gas chromatography (GC) analysis technique..In the test, DDT pesticide residues in the simple compete with enzyme (horseradish peroxidase)-labeled DDT for a limited number of antibody binding sites on the inside surfaces of the test wells; the envirologix plate kit was tested for the measurement of total DDT in virgin and fortified (0-1000 ng g exp-1) soil samples of different properties from Lebanon. Extraction of DDT from soil was done by shaking the samples for 16 hours on a mechanical shaker with 90% methanol without any clean-up steps. Then the samples were allowed to stand for 30 minutes and an aliquot was taken from the clear supernatant. The DDT in the extract was measured in triplicate by GC and ELISA. The results indicated that the two techniques were highly correlated (r2 =0.9671-0.9973). Differences in soils physical and chemical properties did not accuracy of the detection limits of ELISA when compared to GC-ECD results. Immunoassay technique is a suitable method for rapid and accurate measurement of DDT residue in mineral Lebanese soils

  18. Specific T-cell epitopes for immunoassay-based diagnosis of Mycobacterium tuberculosis infection

    DEFF Research Database (Denmark)

    Brock, I; Weldingh, K; Leyten, EM

    2004-01-01

    Specific T-cell epitopes for immunoassay-based diagnosis of Mycobacterium tuberculosis infection.Brock I, Weldingh K, Leyten EM, Arend SM, Ravn P, Andersen P. Department of Infectious Disease Immunology, Statens Serum Institute, Artillerivej 5, DK-2300 Copenhagen S, Denmark. The currently used...... method for immunological detection of tuberculosis infection, the tuberculin skin test, has low specificity. Antigens specific for Mycobacterium tuberculosis to replace purified protein derivative are therefore urgently needed. We have performed a rigorous assessment of the diagnostic potential of four...... recently identified antigens (Rv2653, Rv2654, Rv3873, and Rv3878) from genomic regions that are lacking from the Mycobacterium bovis bacillus Calmette-Guerin (BCG) vaccine strains as well as from the most common nontuberculous mycobacteria. The fine specificity of potential epitopes in these molecules...

  19. Synthesis-based approach toward direct sandwich immunoassay for ciguatoxin CTX3C.

    Science.gov (United States)

    Oguri, Hiroki; Hirama, Masahiro; Tsumuraya, Takeshi; Fujii, Ikuo; Maruyama, Megumi; Uehara, Hisatoshi; Nagumo, Yoko

    2003-06-25

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of ciguatoxin CTX3C were prepared by immunization of mice with protein conjugates of rationally designed synthetic haptens, 3 and 4, in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C itself. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C at the ppb level with no cross-reactivity against other related marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin.

  20. Application of quality function deployment in defense technology development

    Science.gov (United States)

    Cornejo, Estrella De Maria Forster

    1998-12-01

    Introduction. As advances in aviation technology take place, the research community recognizes, and the operator demands that the progress in technology be integrated with the human component of the same, the aircrew. Integrative programs are primarily concerned with three sub-systems: the operator, the aircraft, and the cockpit. To accomplish their integration, a "dialogue" between the various disciplines addressing these aspects of the weapon system is indispensable. Such dialogue is theorized to be possible via Quality Function Deployment (QFD). QFD emphasizes an understanding of the relationships between the requirements of the aircrew and the technology the research and engineering community provides. In establishing these relationships, program management concerns such as need, applicability, affordability, and transition of the technology are addressed. Procedures. QFD was incorporated in a Performance Methodology (PMM). This methodology associates a particular technology's Measures of Performance (MOP) and the overall weapon system's Measures of Effectiveness (MOE) to which it is applied. Incorporation of QFD in the PMM was hypothesized to result in an improved PMM (Q-PMM) that would address both, the aircrew's interests and those of program management. Both methodologies were performed. The g-ensemble was selected as the technology of interest. The Standard and Combat Edge designs were examined for comparison purposes. Technology MOPs were ranked in order of importance in accordance to both the PMM and its proposed improvement, the Q-PMM. These methodologies were then evaluated by way of an experiment in the human centrifuge. This experiment was to answer two questions: Is there a relationship between the technology's MOP and the aircraft's MOEs? Given a MOP-MOE relationship, is there a difference between the two ensembles? Findings. The Q-PMM was superior to the PMM in addressing customer's requirements. The Q-PMM was superior to the PMM in addressing

  1. Optimization of an immunoassay of 2,6-dichlorobenzamide (BAM) and development of regenerative surfaces by immunosorbent modification with newly synthesised BAM hapten library

    DEFF Research Database (Denmark)

    Uthuppu, Basil; Aamand, Jens; Jørgensen, Claus

    2012-01-01

    Dichlobenil is an extensively used herbicide worldwide which is transformed to the mobile 2,6-dichlorobenzamide (BAM) in soil. BAM has been found in many European groundwater resources that are exploited for drinking water. Currently, immunoassay based monitoring technique (plate based ELISA) is ...

  2. Determination of five abused drugs in nitrite-adulterated urine by immunoassays and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Tsai, S C; ElSohly, M A; Dubrovsky, T; Twarowska, B; Towt, J; Salamone, S J

    1998-10-01

    The adulteration of urine specimens with nitrite ion hasseen shown to mask the gas chromatography-mass spectrometry (GC-MS) confirmation testing of marijuana use. This study was designed to further investigate the effect of nitrite adulteration on the detection of five commonly abused drugs by immunoassay screening and GC-MS analysis. The drugs tested are cocaine metabolite (benzoylecgonine), morphine, 11-nor-delta-tetrahydrocannabinol-9-carboxylic acid (THCCOOH), amphetamine, and phencyclidine. The immunoassays evaluated included the instrument-based Abuscreen ONLINE assays, the on-site Abuscreen ONTRAK assays, and the one-step ONTRAK TESTCUP-5 assay. Multianalyte standards containing various levels of drugs were used to test the influence of both potassium and sodium nitrite. In the ONLINE immunoassays, the presence of up to 1.0M nitrite in the multianalyte standards had no significant effect for benzoylecgonine, morphine, and phencyclidine assays. With a high concentration of nitrite, ONLINE became more sensitive for amphetamine (detected more drug than what was expected) and less sensitive for THCCOOH (detected less drug than what was expected). No effects of nitrite were observed on the results of the Abuscreen ONTRAK assays. Similarly, no effects were observed on the absolute qualitative results of the TESTCUP-5 when testing the nitrite-adulterated standards. However, the produced intensities of the signals that indicate the negative test results were slightly lowered in the THC and phencyclidine assays. The presence of 1.0M of nitrite did not show dramatic interference with the GC-MS analysis of benzoylecgonine, morphine, amphetamine, and phencyclidine. In contrast, nitrite ion significantly interfered with the detection of THCCOOH by GC-MS. The presence of 0.03M of nitrite ion resulted in significant loss in the recovery of THCCOOH and its internal standard by GC-MS. The problem of nitrite adulteration could be alleviated by sodium bisulfite treatment even

  3. False Elevation of the Blood Tacrolimus Concentration, as Assessed by an Affinity Column-mediated Immunoassay (ACMIA), Led to Acute T Cell-mediated Rejection after Kidney Transplantation.

    Science.gov (United States)

    Kono, Momoko; Hasegawa, Jumpei; Ogawa, Hina; Yoshikawa, Kanae; Ishiwatari, Ayumi; Wakai, Sachiko; Tanabe, Kazunari; Shirakawa, Hiroki

    2018-05-01

    Tacrolimus is the most commonly used immunosuppressant. Because of its narrow therapeutic range, it is necessary to frequently monitor its concentration. We report the case of a 25-year-old man who underwent kidney transplantation whose tacrolimus concentrations, as measured by an affinity column-mediated immunoassay, were falsely elevated. As we reduced the dose of tacrolimus, the recipient developed T cell-mediated rejection. Using the same blood samples, an enzyme-multiplied immunoassay technique showed that the patient's levels of tacrolimus were extremely low. A further examination indicated that the false increase in the tacrolimus concentration was likely due to an unknown interfering substance. We administered methylprednisolone and antithymocyte-globulin. The patient's serum creatinine level decreased and remained stable after these treatments.

  4. First application of a microsphere-based immunoassay to the detection of genetically modified organisms (GMOs): quantification of Cry1Ab protein in genetically modified maize.

    Science.gov (United States)

    Fantozzi, Anna; Ermolli, Monica; Marini, Massimiliano; Scotti, Domenico; Balla, Branko; Querci, Maddalena; Langrell, Stephen R H; Van den Eede, Guy

    2007-02-21

    An innovative covalent microsphere immunoassay, based on the usage of fluorescent beads coupled to a specific antibody, was developed for the quantification of the endotoxin Cry1Ab present in MON810 and Bt11 genetically modified (GM) maize lines. In particular, a specific protocol was developed to assess the presence of Cry1Ab in a very broad range of GM maize concentrations, from 0.1 to 100% [weight of genetically modified organism (GMO)/weight]. Test linearity was achieved in the range of values from 0.1 to 3%, whereas fluorescence signal increased following a nonlinear model, reaching a plateau at 25%. The limits of detection and quantification were equal to 0.018 and 0.054%, respectively. The present study describes the first application of quantitative high-throughput immunoassays in GMO analysis.

  5. Personalized Integrated Educational System: Technology Functions for the Learner- Centered Paradigm of Education

    Science.gov (United States)

    Reigeluth, Charles M.; Aslan, Sinem; Chen, Zengguan; Dutta, Pratima; Huh, Yeol; Lee, Dabae; Lin, Chun-Yi; Lu, Ya-Huei; Min, Mina; Tan, Verily; Watson, Sunnie Lee; Watson, William R.

    2015-01-01

    The learner-centered paradigm of instruction differs in such fundamental ways from the teacher-centered paradigm that it requires technology to serve very different functions. In 2006, a research team at Indiana University began to work on identifying those functions and published their results in 2008. Subsequently, the team elaborated and…

  6. Results of the HPL determination using a new enzymatic immunoassay - comparison with a commercial radioimmunoassay

    International Nuclear Information System (INIS)

    Leis, D.; Schneider, B.; Keller, A.; Braun, S.

    1982-01-01

    An enzymatic immunoassay recently developed by the firm Organon, Oss, Netherlands, to determine HPL in the serum of pregnant women was compared to a widely used radioimmunoassay marketed by the firm Amersham-Buchler, Braunschweig. The values determined showed a good correlation. The accuracy of measurement was within the generally accepted range for immunological assays of this kind. The assay procedures are comparable with regard to the expenditure of time and work. A great advantage of the EIA is due to the absence of radioactive substances, which permits this test to be performed in any laboratory equipped with a centrifuge and photometer. (orig.) [de

  7. Neurorehabilitation and neuroprosthetic technologies to regain motor function following spinal cord injury

    OpenAIRE

    van den Brand, Rubia

    2014-01-01

    Spinal cord injury (SCI) leads to a range of disabilities, including locomotor impairments that seriously diminish the patients’ quality of life. Strategies to promote functional recovery after severe SCI will undoubtedly include approaches to regenerate injured pathways. The present work pursues a less ambitious, but potentially more rapidly applicable approach to improve function after SCI by applying neurorehabilitation augmented with neuroprosthetic technologies. In an intact situation, t...

  8. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    OpenAIRE

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter; Troldborg, Carl Peder; Fodgaard, Henrik; van Os, Sylvana; Pedersen, Christian

    2017-01-01

    High-sensitivity cardiac troponin assay development enables determination of biological variation in healthy populations, more accurate interpretation of clinical results and points towards earlier diagnosis and rule-out of acute myocardial infarction. In this paper, we report on preliminary tests of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by fac...

  9. Covalent Binding of Antibodies to Cellulose Paper Discs and Their Applications in Naked-eye Colorimetric Immunoassays.

    Science.gov (United States)

    Peng, Yanfen; Gelder, Victor Van; Amaladoss, Anburaj; Patel, Kadamb Haribhai

    2016-10-21

    This report presents two methods for the covalent immobilization of capture antibodies on cellulose filter paper grade No. 1 (medium-flow filter paper) discs and grade No. 113 (fast-flow filter paper) discs. These cellulose paper discs were grafted with amine functional groups through a silane coupling technique before the antibodies were immobilized on them. Periodate oxidation and glutaraldehyde cross-linking methods were used to graft capture antibodies on the cellulose paper discs. In order to ensure the maximum binding capacity of the capture antibodies to their targets after immobilization, the effects of various concentrations of sodium periodate, glutaraldehyde, and capture antibodies on the surface of the paper discs were investigated. The antibodies that were coated on the amine-functionalized cellulose paper discs through a glutaraldehyde cross-linking agent showed enhanced binding activity to the target when compared to the periodate oxidation method. IgG (in mouse reference serum) was used as a reference target in this study to test the application of covalently immobilized antibodies through glutaraldehyde. A new paper-based, enzyme-linked immunosorbent assay (ELISA) was successfully developed and validated for the detection of IgG. This method does not require equipment, and it can detect 100 ng/ml of IgG. The fast-flow filter paper was more sensitive than the medium-flow filter paper. The incubation period of this assay was short and required small sample volumes. This naked-eye, colorimetric immunoassay can be extended to detect other targets that are identified with conventional ELISA.

  10. Multiplex Immunoassay of Plasma Cytokine Levels in Men with Alcoholism and the Relationship to Psychiatric Assessments.

    Science.gov (United States)

    Manzardo, Ann M; Poje, Albert B; Penick, Elizabeth C; Butler, Merlin G

    2016-03-29

    Chronic alcohol use alters adaptive immunity and cytokine activity influencing immunological and hormone responses, inflammation, and wound healing. Brain cytokine disturbances may impact neurological function, mood, cognition and traits related to alcoholism including impulsiveness. We examined the relationship between plasma cytokine levels and self-rated psychiatric symptoms in 40 adult males (mean age 51 ± 6 years; range 33-58 years) with current alcohol dependence and 30 control males (mean age 48 ± 6 years; range 40-58 years) with no history of alcoholism using multiplex sandwich immunoassays with the Luminex magnetic-bead based platform. Log-transformed cytokine levels were analyzed for their relationship with the Symptom Checklist-90R (SCL-90R), Barratt Impulsivity Scales (BIS) and Alcoholism Severity Scale (ASS). Inflammatory cytokines (interferon γ-induced protein-10 (IP-10); monocyte chemoattractant protein-1 (MCP1); regulated on activation, normal T cell expressed and secreted (RANTES)) were significantly elevated in alcoholism compared to controls while bone marrow-derived hematopoietic cytokines and chemokines (granulocyte-colony stimulating factor (GCSF); soluble CD40 ligand (sCD40L); growth-related oncogene (GRO)) were significantly reduced. GRO and RANTES levels were positively correlated with BIS scales; and macrophage-derived chemokine (MDC) levels were positively correlated with SCL-90R scale scores (p alcoholism may influence brain function leading to increased impulsiveness and/or phobia. The novel association between RANTES and GRO and impulsivity phenotype in alcoholism should be further investigated in alcoholism and psychiatric conditions with core impulsivity and anxiety phenotypes lending support for therapeutic intervention.

  11. Sources of variation in an enzyme-linked immunoassay of bluetongue virus in Culicoides variipennis (Diptera: Ceratopogonidae).

    Science.gov (United States)

    Tabachnick, W J; Mecham, J O

    1991-03-01

    An enzyme-linked immunoassay for detecting bluetongue virus in infected Culicoides variipennis was evaluated using a nested analysis of variance to determine sources of experimental error in the procedure. The major source of variation was differences among individual insects (84% of the total variance). Storing insects at -70 degrees C for two months contributed to experimental variation in the ELISA reading (14% of the total variance) and should be avoided. Replicate assays of individual insects were shown to be unnecessary, since variation among replicate wells and plates was minor (2% of the total variance).

  12. Immunoassay for serum amyloid A using a glassy carbon electrode modified with carboxy-polypyrrole, multiwalled carbon nanotubes, ionic liquid and chitosan

    International Nuclear Information System (INIS)

    Xia, Chunyong; Li, Yuan; Yuan, Guolin; Guo, Yanlei; Yu, Chao

    2015-01-01

    We report on a highly sensitive electrochemical immunoassay for the serum inflammation marker amyloid A (SAA). It is making use of a glassy carbon electrode that was modified with carboxy-endcapped polypyrrole (PPy-α-COOH), multiwalled carbon nanotubes (MWCNTs), ionic liquid and chitosan acting as the support platform. The nanocomposite increases the sensitivity and stability of the assay. Antibody against SAA was immobilized on a monolayer surface consisting of PPy-α-COOH. The electrode material was characterized by scanning electron microscopy, transmission electron microscopy, Fourier transform infrared spectra, cyclic voltammetry, electrochemical impedance spectroscopy and differential pulse voltammetry. The calibration plot for this assay, when operated at 0.16 V (vs. SCE) and applied to spiked serum samples, is linear in the 0.001 to 900 ng mL −1 SAA concentration range, and the detection limit is as low as 0.3 pg mL −1 (at an S/N ratio of 3). The electrode is stable and highly sensitive. The detection scheme is likely to be applicable to numerous other kinds of immunoassays. (author)

  13. The Role of Executive Functioning and Technological Anxiety (FOMO in College Course Performance as Mediated by Technology Usage and Multitasking Habits

    Directory of Open Access Journals (Sweden)

    Larry D. Rosen

    2017-12-01

    Full Text Available This study investigated how technology use impacts academic performance. A proposed model postulated that academic performance could be predicted by a cognitive independent variable-executive functioning problems-and an affective independent variable-technological anxiety or FOMO (fear of missing out-mediated by how students choose to use technology. An unobtrusive smartphone application called “Instant Quantified Self” monitored daily smartphone unlocks and daily minutes of use. Other mediators included self-reported smartphone use, self-observed studying attention, self-reported multitasking preference, and a classroom digital metacognition tool that assessed the student’s ability to understand the ramifications of technology use in the classroom that is not relevant to the learning process. Two hundred sixteen participants collected an average of 56 days of “Instant” application data, demonstrating that their smartphone was unlocked more than 60 times a day for three to four minutes each time for a total of 220 daily minutes of use. Results indicated that executive functioning problems predicted academic course performance mediated by studying attention and a single classroom digital metacognition subscale concerning availability of strategies of when to use mobile phones during lectures. FOMO predicted performance directly as well as mediated by a second classroom digital metacognition concerning attitudes toward mobile phone use during lectures. Implications for college students and professors include increasing metacognition about technology use in the classroom and taking “tech breaks” to reduce technology anxiety.

  14. A three-parameter langmuir-type model for fitting standard curves of sandwich enzyme immunoassays with special attention to the α-fetoprotein assay

    NARCIS (Netherlands)

    Kortlandt, W.; Endeman, H.J.; Hoeke, J.O.O.

    In a simplified approach to the reaction kinetics of enzyme-linked immunoassays, a Langmuir-type equation y = [ax/(b + x)] + c was derived. This model proved to be superior to logit-log and semilog models in the curve-fitting of standard curves. An assay for α-fetoprotein developed in our laboratory

  15. Fiscal 1993 technological survey report. R and D project for industrial science and technology (R and D of quantum functional device - studies on technological prediction); 1993 nendo ryoshi kino soshi no kenkyu kaihatsu (gijutsu yosoku kenkyu) seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-03-01

    Researches are in progress with a view to establishing fundamental technology for a quantum functional device, which engineeringly uses various quantum mechanical effects emerging in a ultrafine dimentional area, for the purpose of contributing to the micro electronics technology that deals with ultra high speed and ultra high functional information processing necessitated in an advanced information-oriented society. Survey on research activities was conducted concerning the peripheral technologies of a quantum functional device project, for example, related technologies such as a high temperature scanning tunneling microscope enabling preparation of a micro structure of nm order, and an ultra high vacuum CVD device. In addition, discussions were held on the subjects of preparation/evaluation technology of a quantum functional device and a single electronic device, with the purpose of predicting/judging, from a wider viewpoint, indications of unexpected research results of the R and D in the remarkably evolving field of quantum functional devices, quickly taking the indications into projects, and efficiently promoting the R and D by making sure of the directions to proceed. (NEDO)

  16. From the Laboratory to the Classroom: A Technology-Intensive Curriculum for Functions and Graphs.

    Science.gov (United States)

    Magidson, Susan

    1992-01-01

    Addresses the challenges, risks, and rewards of teaching about linear functions in a technology-rich environment from a constructivist perspective. Describes an algebra class designed for junior high school students that focuses of the representations and real-world applications of linear functions. (MDH)

  17. The roles and functions of a lunar base Nuclear Technology Center

    International Nuclear Information System (INIS)

    Buden, D.; Angelo, J.A. Jr.

    1991-01-01

    This paper describes the roles and functions of a special Nuclear Technology Center which is developed as an integral part of a permanent lunar base. Numerous contemporary studies clearly point out that nuclear energy technology will play a major role in any successful lunar/Mars initiative program and in the overall establishment of humanity's solar system civilization. The key role of nuclear energy in the providing power has been recognized. A Nuclear Technology Center developed as part of of a permanent lunar base can also help bring about many other nuclear technology applications, such as producing radioisotopes for self-illumination, food preservation, waste sterilization, and medical treatment; providing thermal energy for mining, materials processing and agricultural; and as a source of emergency habitat power. Designing such a center will involve the deployment, operation, servicing and waste product management and disposal of megawatt class reactor power plants. This challenge must be met with a minimum of direct human support at the facility. Furthermore, to support the timely, efficient integration of this Nuclear Technology Center in the evolving lunar base infrastructure, an analog of such a facility will be needed here on Earth. 12 refs., 4 figs., 1 tab

  18. Clinical Validation of a Point-of-Care Multiplexed In Vitro Immunoassay Using Monoclonal Antibodies (the MSD Influenza Test) in Four Hospitals in Vietnam

    NARCIS (Netherlands)

    van Doorn, H. Rogier; Kinh, Nguyen Van; Tuan, Ha Manh; Tuan, Tran Anh; Minh, Ngo Ngoc Quang; Bryant, Juliet E.; Hang, Vu thi Ty; Uyen, Le thi Tham; Thinh, Le Quoc; Anh, Tran thi Ngoc; Lan, Nguyen Phu Huong; Trung, Nguyen Vu; Taylor, Walter; Merson, Laura; Wertheim, Heiman F. L.; Farrar, Jeremy; Wolbers, Marcel; Chau, Nguyen Van Vinh; de Jong, Menno D.

    2012-01-01

    Point-of-care (POC) diagnostic tests for influenza can considerably shorten the time to clinical decision making. An investigational POC test based on a multiplexed immunoassay was developed by Meso Scale Diagnostics, LLC (MSD), with the objective to make a more sensitive rapid test that can also

  19. Development and statistical assessment of a paper-based immunoassay for detection of tumor markers

    Energy Technology Data Exchange (ETDEWEB)

    Mazzu-Nascimento, Thiago [Instituto de Química de São Carlos, Universidade de São Paulo, 13566-590, São Carlos, SP (Brazil); Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP (Brazil); Morbioli, Giorgio Gianini [Instituto de Química de São Carlos, Universidade de São Paulo, 13566-590, São Carlos, SP (Brazil); Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP (Brazil); School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA 30332 (United States); Milan, Luis Aparecido [Departamento de Estatística, Universidade Federal de São Carlos, São Carlos, SP (Brazil); Donofrio, Fabiana Cristina [Instituto de Ciências da Saúde, Universidade Federal de Mato Grosso, 78557-267, Sinop, MT (Brazil); Mestriner, Carlos Alberto [Wama Produtos para Laboratório Ltda, 13560-971, São Carlos, SP (Brazil); Carrilho, Emanuel, E-mail: emanuel@iqsc.usp.br [Instituto de Química de São Carlos, Universidade de São Paulo, 13566-590, São Carlos, SP (Brazil); Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP (Brazil)

    2017-01-15

    Paper-based assays are an attractive low-cost option for clinical chemistry testing, due to characteristics such as short time of analysis, low consumption of samples and reagents, and high portability of assays. However, little attention has been given to the evaluation of the performance of these simple tests, which should include the use of a statistical approach to define the choice of best cut-off value for the test. The choice of the cut-off value impacts on the sensitivity and specificity of the bioassay. Here, we developed a paper-based immunoassay for the detection of the carcinoembryonic antigen (CEA) and performed a statistical assessment to establish the assay's cut-off value using the Youden's J index (68.28 A.U.), what allowed for a gain in sensibility (0.86) and specificity (1.0). We also discuss about the importance of defining a gray zone as a safety margin for test (±12% over the cut-off value), eliminating all false positives and false negatives outcomes and avoiding misleading results. The test accuracy was calculated as the area under the curve (AUC) of the receiver operating characteristic (ROC) curve, presenting a value of 0.97, what classifies this test as highly accurate. We propose here a low-cost method capable of detecting carcinoembryonic antigen (CEA) in human serum samples, highlighting the importance of statistical tools to evaluate a new low-cost diagnostic method. - Highlights: • A paper-based sandwich immunoassay protocol for detection of tumor markers. • A statistical approach to define cut-off values and measuring test's sensitivity, specificity and accuracy. • A simple way to create a gray zone, avoiding false positive and false negative outcomes.

  20. A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Piccini, Matthew Ernest [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Cepheid, Sunnyvale, CA (United States); Schaff, Ulrich Y. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Stanker, Larry H. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Cheng, Luisa W. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Ravichandran, Easwaran [Univ. of Massachusetts, Dartmouth, MA (United States); Singh, Bal-Ram [Univ. of Massachusetts, Dartmouth, MA (United States); Sommer, Greg J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Singh, Anup K. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-01-01

    Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

  1. Survey of technological trends in functional membrane materials; Kinosei makuzai ni kansuru gijutsu doko chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1979-03-01

    Materials for membranes with novel functions are surveyed. The survey is focused on 10 subjects, which are high-performance RO (reverse osmosis)/UF (ultrafiltration) membranes; development of an energy-efficient secondary treatment system for urban wastewater using pollution-free membranes; high-performance ion exchange membranes; artificial lung membranes; hydrogen separation membranes (hydrogen as energy); development of an energy-efficient combustion system using gas separation membranes (oxygen-enriched membranes); organic matter separation membranes; enzyme-aided chemical reaction membranes and their application; development of a distilling ship; and functional membranes making use of photosynthesis. Discussed in this connection are the outlines of the technologies, the need of their development, methods and contents of the development efforts, and the effects and impacts of their development. The survey further concerns the particulars of the trends in novel technologies about functional membrane materials development, covering gas separation and liquid separation technologies; chemical reaction membranes; and enzyme-aided chemical reaction membranes and their application systems. As for their application, the survey covers the field of application of desalinated or ultrapure water; field of application of food fermentation technologies; industrial wastewater, valuable materials recovery, and urban wastewater treatment; and application to medical systems. (NEDO)

  2. Homogenous 96-plex PEA immunoassay exhibiting high sensitivity, specificity, and excellent scalability

    DEFF Research Database (Denmark)

    Assarsson, Erika; Lundberg, Martin; Holmquist, Göran

    2014-01-01

    reporters, shown potential to relieve the shortcomings of antibodies and their inherent cross-reactivity in multiplex protein quantification applications. The aim of the present study was to develop a robust 96-plex immunoassay based on the proximity extension assay (PEA) for improved high throughput...... detection of protein biomarkers. This was enabled by: (1) a modified design leading to a reduced number of pipetting steps compared to the existing PEA protocol, as well as improved intra-assay precision; (2) a new enzymatic system that uses a hyper-thermostabile enzyme, Pwo, for uniting the two probes......, such as serum and plasma, and also in xenografted mice and resuspended dried blood spots, consuming only 1 µL sample per test. All-in-all, the development of the current multiplex technique is a step toward robust high throughput protein marker discovery and research....

  3. Estrogen receptor determination in endometrial carcinoma: ligand binding assay versus enzyme immunoassay

    DEFF Research Database (Denmark)

    Nyholm, H C; Nielsen, Anette Lynge; Lyndrup, J

    1995-01-01

    We compared concentrations of cytosolic estrogen receptors (ERc) measured in 35 postmenopausal endometrial carcinomas by ligand binding method (LBA) (dextran-coated charcoal assay) and enzyme immunoassay (EIA). Correlations between ERc, nuclear estrogen receptors (ERn) determined by EIA......, and cytosolic progesterone receptors (PR) measured by LBA were also studied. While ERc concentrations determined by LBA and EIA were highly correlated (r: 0.94), ERc values detected by LBA were approximately twice those found by EIA (median values of ERc: 155 vs. 64 fmol/mg cytosol protein, DCC vs. EIA......). The percentages of ERc positive tumors were 89% by LBA and 77% by EIA. The median fraction of total ER present as ERn was 63%. PR levels correlated positively with ERn concentrations (r: 0.73). We explore possible reasons why greater concentrations of ERc are determined by estradiol binding than by the ER-EIA kit...

  4. Pharmacokinetic analysis of topical tobramycin in equine tears by automated immunoassay.

    Science.gov (United States)

    Czerwinski, Sarah L; Lyon, Andrew W; Skorobohach, Brian; Léguillette, Renaud

    2012-08-21

    Ophthalmic antibiotic therapy in large animals is often used empirically because of the lack of pharmacokinetics studies. The purpose of the study was to determine the pharmacokinetics of topical tobramycin 0.3% ophthalmic solution in the tears of normal horses using an automated immunoassay analysis. The mean tobramycin concentrations in the tears at 5, 10, 15, 30 minutes and 1, 2, 4, 6 hours after administration were 759 (±414), 489 (±237), 346 (±227), 147 (±264), 27.6 (±28.4), 14.8 (±66.6), 6.7 (±18.6), and 23.4 (±73.4) mg/L. Mean tobramycin concentration was maintained above the MIC90 for commonly isolated bacteria for 68.5 min. A single dose of topical tobramycin resulted in therapeutic concentrations of tobramycin in the tears for 1 h after administration. Therapeutic levels of tobramycin remained in equine tears 6 times longer than was reported in rabbit tears.

  5. Development of Fully Automated Low-Cost Immunoassay System for Research Applications.

    Science.gov (United States)

    Wang, Guochun; Das, Champak; Ledden, Bradley; Sun, Qian; Nguyen, Chien

    2017-10-01

    Enzyme-linked immunosorbent assay (ELISA) automation for routine operation in a small research environment would be very attractive. A portable fully automated low-cost immunoassay system was designed, developed, and evaluated with several protein analytes. It features disposable capillary columns as the reaction sites and uses real-time calibration for improved accuracy. It reduces the overall assay time to less than 75 min with the ability of easy adaptation of new testing targets. The running cost is extremely low due to the nature of automation, as well as reduced material requirements. Details about system configuration, components selection, disposable fabrication, system assembly, and operation are reported. The performance of the system was initially established with a rabbit immunoglobulin G (IgG) assay, and an example of assay adaptation with an interleukin 6 (IL6) assay is shown. This system is ideal for research use, but could work for broader testing applications with further optimization.

  6. Production of monoclonal antibodies for sandwich immunoassay detection of Pacific ciguatoxins.

    Science.gov (United States)

    Tsumuraya, Takeshi; Fujii, Ikuo; Hirama, Masahiro

    2010-10-01

    Ciguatoxins are the major causative toxins of ciguatera seafood poisoning. Limited availability of ciguatoxins has hampered the development of a reliable and specific immunoassay for detecting these toxins in contaminated fish. Monoclonal antibodies (mAbs) specific against both ends of Pacific ciguatoxins CTX3C and 51-hydroxyCTX3C were prepared by immunization of mice with the protein conjugates of rationally designed synthetic haptens in place of the natural toxin. Haptenic groups that possess a surface area larger than 400 A(2) were required to produce mAbs that can bind strongly to CTX3C or 51-hydroxyCTX3C. A direct sandwich enzyme-linked immunosorbent assay (ELISA) using these mAbs was established to detect CTX3C and 51-hydroxyCTX3C at the ppb level with no cross-reactivity against the other marine toxins, including brevetoxin A, brevetoxin B, okadaic acid, or maitotoxin. Copyright 2009 Elsevier Ltd. All rights reserved.

  7. Immunoassays for the measurement of IGF-II, IGFBP-2 and -3, and ICTP as indirect biomarkers of recombinant human growth hormone misuse in sport. Values in selected population of athletes.

    Science.gov (United States)

    Abellan, Rosario; Ventura, Rosa; Palmi, Ilaria; di Carlo, Simonetta; Bacosi, Antonella; Bellver, Montse; Olive, Ramon; Pascual, Jose Antonio; Pacifici, Roberta; Segura, Jordi; Zuccaro, Piergiorgio; Pichini, Simona

    2008-11-04

    Insulin-like growth factor-II (IGF-II), insulin-like growth factor binding proteins (IGFBPs) -2 and -3 and C-terminal telopeptide of type I collagen (ICTP) have been proposed, among others, as indirect biomarkers of the recombinant human growth hormone misuse in sport. An extended intra- and inter-laboratory validation of commercially available immunoassays for biomarkers detection was performed. ELISA assays for total IGF-II, IGFBP-2 and IGFBP-3 (IGF-II/ELISA1: DSLabs, IGFBP-2/ELISA2: Biosource, and IGFBP-3/ELISA3: BioSource) and an EIA assay for ICTP (ICTP/EIA: Orion Diagnostica) were evaluated. The inter- and intra-laboratory precision values were acceptable for all evaluated assays (maximum imprecision of 30% and 66% were found only for the lowest quality control samples of IGF-II and IGFBP-3). Correct accuracy was obtained for all inter-laboratory immunoassays and for IGFBP-2 intra-laboratory immunoassay. The range of concentrations found in serum samples under investigation was always covered by the calibration curves of the studied immunoassays. However, 11% and 15% of the samples felt below the estimated LOQ for IGF-II and ICTP, respectively, in the zone where lower precision was obtained. Although the majority of evaluated assays showed an overall reliability not always suitable for antidoping control analysis, relatively high concordances between laboratory results were obtained for all assays. Evaluated immunoassays were used to measure serum concentrations of IGF-II, IGFBP-2 and -3 and ICTP in elite athletes of various sport disciplines at different moments of the training season; in recreational athletes at baseline conditions and finally in sedentary individuals. Serum IGF-II was statistically higher both in recreational and elite athletes compared to sedentary individuals. Elite athletes showed lower IGFBP-2 and higher IGFBP-3 concentration with respect to recreational athletes and sedentary people. Among elite athletes, serum IGFBP-3 (synchronized

  8. Significance of isolated reactive treponemal chemiluminescence immunoassay results.

    Science.gov (United States)

    Hunter, Michael G; Robertson, Peter W; Post, Jeffrey J

    2013-05-01

    Isolated reactive serum treponemal chemiluminescence immunoassay (CIA) specimens cause clinical uncertainty. Sera were screened by CIA, and reactive samples underwent reflex testing with rapid plasma reagin (RPR), Treponema pallidum particle agglutination (TPPA), and fluorescent treponemal antibody absorption (FTA Abs) assays. Samples reactive only on the CIA were deemed "isolated" reactive CIA samples. We undertook detailed review of a subset of subjects with isolated reactive CIA specimens. Of 28 261 specimens, 1171 (4.1%) were reactive on CIA, of which 133 (11.3%) had isolated CIA reactivity. Most subjects (66 of 82 [80.5%]) with isolated reactive CIA specimens were from high-prevalence populations. We found evidence of CIA, TPPA, and FTA Abs seroreversion. The median chemiluminescent signal-to-cutoff ratio was similar for isolated reactive CIA sera and sera that were reactive on either FTA Abs or TPPA assays (2.19 vs 2.32; P = .15) but lower than for sera reactive on both FTA Abs and TPPA assays (12.37; P < .001) or for sera reactive on RPR assays (25.53; P < .001). A total of 11 of 20 patients (55%) with an isolated reactive CIA specimen who underwent medical record review had previous or subsequent evidence of syphilis infection. Isolated reactive CIA specimens may represent true T. pallidum infection and may be found after seroreversion of traditional treponemal assays.

  9. Multicentric Evaluation of New Commercial Enzyme Immunoassays for the Detection of Immunoglobulin M and Total Antibodies against Hepatitis A Virus▿

    Science.gov (United States)

    Arcangeletti, M. C.; Dussaix, E.; Ferraglia, F.; Roque-Afonso, A. M.; Graube, A.; Chezzi, C.

    2011-01-01

    A multicentric clinical study was conducted on representative sera from 1,738 European and U.S. subjects for the evaluation of new anti-hepatitis A virus enzyme immunoassays from Bio-Rad Laboratories. Comparison with reference DiaSorin S.p.A. tests confirmed the good performance of Bio-Rad assays (99.85% and 99.47% overall agreement in detecting total antibodies and IgM, respectively). PMID:21653739

  10. Technology-aided assessment of sensori-motor function in early infancy

    Directory of Open Access Journals (Sweden)

    Alessandro G Allievi

    2014-10-01

    Full Text Available There is a pressing need for new techniques capable of providing accurate information about sensori-motor function during the first 2 years of childhood. Here we review current clinical methods and challenges for assessing motor function in early infancy, and discuss the potential benefits of applying technology-assisted methods. We also describe how the use of these tools with neuroimaging, and in particular functional magnetic resonance imaging (fMRI, can shed new light on the intra-cerebral processes underlying neurodevelopmental impairment. This knowledge is of particular relevance in the early infant brain which has an increased capacity for compensatory neural plasticity. Such tools could bring a wealth of knowledge about the underlying pathophysiological processes of diseases such as cerebral palsy; act as biomarkers to monitor the effects of possible therapeutic interventions; and provide clinicians with much needed early diagnostic information.

  11. Breaking through barriers: using technology to address executive function weaknesses and improve student achievement.

    Science.gov (United States)

    Schwartz, David M

    2014-01-01

    Assistive technologies provide significant capabilities for improving student achievement. Improved accessibility, cost, and diversity of applications make integration of technology a powerful tool to compensate for executive function weaknesses and deficits and their impact on student performance, learning, and achievement. These tools can be used to compensate for decreased working memory, poor time management, poor planning and organization, poor initiation, and decreased memory. Assistive technology provides mechanisms to assist students with diverse strengths and weaknesses in mastering core curricular concepts.

  12. Fiscal 1993 technological survey report. R and D project for industrial science and technology (R and D of quantum functional device); 1993 nendo ryoshi kino soshi no kenkyu kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-03-01

    An examination is in progress with a view to establishing fundamental technology for a quantum functional device, which engineeringly uses various quantum mechanical effects emerging in a ultrafine dimentional area, for the purpose of contributing to the micro electronics technology that deals with ultra high speed and ultra high functional information processing necessitated in an advanced information-oriented society. As a general research study, survey on the technological trend was done, as was the analysis/examination of the R and D. In regard to the R and D of quantization technology, with the object of structuring an element device by means of quantization functions and structuring an integration system, examinations were made on tunneling in semiconductors, physical phenomenon like electrical conduction, ultrafine fabrication techniques, etc., with R and D conducted on structures and forming technique for realizing quantization functions such as quantum wire and quantum dot, crystal growing technology, simulation technology, design of materials, etc.. (NEDO)

  13. Enhanced Sensitive Immunoassay: Noncompetitive Phage Anti-Immune Complex Assay for the Determination of Malachite Green and Leucomalachite Green

    Science.gov (United States)

    2015-01-01

    To develop a more sensitive immunoassay for malachite green (MG) and leucomalachite green (LMG), we identified the immunocomplex binding phage-borne peptides for use in the noncompetitive phage anti-immunocomplex assay (PHAIA). An anti-LMG monoclonal antibody (mAb) was used to select immunocomplex binding peptides from a circular random eight-amino-acid phage-displayed library. After three rounds of panning-elution, five peptides that bound the LMG–mAb immunocomplex were obtained. One of the phage-borne peptide clones that resulted in an assay with the highest sensitivity was chosen for further research. The concentration of LMG producing 50% of the saturated signal and the limit of detection of the assay were 7.02 and 0.55 ng/mL, respectively, with a linear range of 1.35 to 21.56 ng/mL. The PHAIA based on the same antibody was 16 times more sensitive compared to the competitive immunoassay. PHAIA was used to analyze LMG, MG, and two mixtures of spiked fish samples, with validation by high-performance liquid chromatography (HPLC) with fluorescence detector. Results showed a good correlation (R2LMG = 0.9841; R2MG = 0.993; R2Mixture = 0.9903) between the data of PHAIA and HPLC, thus the assay was an efficient method for monitoring food safety. PMID:25077381

  14. Carbon capture and sequestration (CCS) technological innovation system in China: Structure, function evaluation and policy implication

    International Nuclear Information System (INIS)

    Lai Xianjin; Ye Zhonghua; Xu Zhengzhong; Husar Holmes, Maja; Henry Lambright, W.

    2012-01-01

    Carbon capture and sequestration (CCS) can be an important technology option for China in addressing global climate change and developing clean energy technologies. Promoted by international climate conventions and supported by government research and development programs, an increasing number of CCS pilot and demonstration projects have been launched in China. In this study, we analyze the structure of China’s CCS effort from a technological innovation system (TIS) perspective. Within this system, key socio-political components, including institutions, actor-networks, and technology development, are examined to evaluate the state of the innovation system. The study assessed the perceived capacity of seven functional areas of the CCS innovation system through a survey of key CCS actors and stakeholders. The findings suggest that China’s CCS innovation system has a strong functional capacity for knowledge and technology development. It is significantly weaker in the innovative functions of knowledge diffusion, market formation, facilitating entrepreneurs and new entrants into the CCS market. Based on the evaluation of China’s technological innovation system to develop CCS, the article articulates specific public policies to formulate a more robust innovation system to traverse the “valley of death” from research and development to commercial deployment and accelerate energy innovation in China. - Highlights: ► We analyze and evaluate China’s CCS innovation system from TIS perspective. ► Strong and systematic CCS innovation system structure has come into being in China. ► The system has acquired high knowledge development and accumulation. ► Weak innovation functions are identified: market creation, guidance, etc. ► Public policies are needed to improve the innovation system performance.

  15. A Homogeneous Time-Resolved Fluorescence Immunoassay Method for the Measurement of Compound W.

    Science.gov (United States)

    Huang, Biao; Yu, Huixin; Bao, Jiandong; Zhang, Manda; Green, William L; Wu, Sing-Yung

    2018-01-01

    Using compound W (a 3,3'-diiodothyronine sulfate [T 2 S] immuno-crossreactive material)-specific polyclonal antibodies and homogeneous time-resolved fluorescence immunoassay assay techniques (AlphaLISA) to establish an indirect competitive compound W (ICW) quantitative detection method. Photosensitive particles (donor beads) coated with compound W or T 2 S and rabbit anti-W antibody were incubated with biotinylated goat anti-rabbit antibody. This constitutes a detection system with streptavidin-coated acceptor particle. We have optimized the test conditions and evaluated the detection performance. The sensitivity of the method was 5 pg/mL, and the detection range was 5 to 10 000 pg/mL. The intra-assay coefficient of variation averages W levels in extracts of maternal serum samples. This may have clinical application to screen congenital hypothyroidism in utero.

  16. Electron beam technology for modifying the functional properties of maize starch

    International Nuclear Information System (INIS)

    Nemtanu, M.R.; Minea, R.; Kahraman, K.; Koksel, H.; Ng, P.K.W.; Popescu, M.I.; Mitru, E.

    2007-01-01

    Maize starch is a versatile biopolymer with a wide field of applications (e.g. foods, pharmaceutical products, adhesives, etc.). Nowadays there is a continuous and intensive search for new methods and techniques to modify its functional properties due to the fact that native form of starch may exhibit some disadvantages in certain applications. Radiation technology is frequently used to change the properties of different polymeric materials. Thus, the goal of the work is to discuss the application of accelerated electron beams on maize starch in the view of changing some of its functional properties. Maize starch has been irradiated with doses up to 52.15 kGy by using electron beam technology and the modifications of differential scanning calorimetry (DSC) and pasting characteristics, paste clarity, freezing and thawing stability as well as colorimetric characteristics have been investigated. The results of the study revealed that the measured properties can be modified by electron beam treatment and, therefore, this method can be an efficient and ecological alternative to obtain modified maize starch

  17. Rapid Detection of Biological and Chemical Threat Agents Using Physical Chemistry, Active Detection, and Computational Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung; Dong, Li; Fu, Rong; Liotta, Lance; Narayanan, Aarthi; Petricoin, Emanuel; Ross, Mark; Russo, Paul; Zhou, Weidong; Luchini, Alessandra; Manes, Nathan; Chertow, Jessica; Han, Suhua; Kidd, Jessica; Senina, Svetlana; Groves, Stephanie

    2007-01-01

    Basic technologies have been successfully developed within this project: rapid collection of aerosols and a rapid ultra-sensitive immunoassay technique. Water-soluble, humidity-resistant polyacrylamide nano-filters were shown to (1) capture aerosol particles as small as 20 nm, (2) work in humid air and (3) completely liberate their captured particles in an aqueous solution compatible with the immunoassay technique. The immunoassay technology developed within this project combines electrophoretic capture with magnetic bead detection. It allows detection of as few as 150-600 analyte molecules or viruses in only three minutes, something no other known method can duplicate. The technology can be used in a variety of applications where speed of analysis and/or extremely low detection limits are of great importance: in rapid analysis of donor blood for hepatitis, HIV and other blood-borne infections in emergency blood transfusions, in trace analysis of pollutants, or in search of biomarkers in biological fluids. Combined in a single device, the water-soluble filter and ultra-sensitive immunoassay technique may solve the problem of early warning type detection of aerosolized pathogens. These two technologies are protected with five patent applications and are ready for commercialization.

  18. The Sandia MEMS Passive Shock Sensor : FY08 testing for functionality, model validation, and technology readiness.

    Energy Technology Data Exchange (ETDEWEB)

    Walraven, Jeremy Allen; Blecke, Jill; Baker, Michael Sean; Clemens, Rebecca C.; Mitchell, John Anthony; Brake, Matthew Robert; Epp, David S.; Wittwer, Jonathan W.

    2008-10-01

    This report summarizes the functional, model validation, and technology readiness testing of the Sandia MEMS Passive Shock Sensor in FY08. Functional testing of a large number of revision 4 parts showed robust and consistent performance. Model validation testing helped tune the models to match data well and identified several areas for future investigation related to high frequency sensitivity and thermal effects. Finally, technology readiness testing demonstrated the integrated elements of the sensor under realistic environments.

  19. Evidence for carcinoembryonic antigen using radioimmunoassay and enzyme immunoassay

    International Nuclear Information System (INIS)

    Kungda Gao, L.

    1980-01-01

    A commercially available radioimmunoassay for the determination of carcinoembryonic antigen (CEA) was initially compared with an enzyme immunoassay (EIA). Considerable differences were found between the individual value. For three patients suffering from carcinomas of the digestive tract a better indication of the disease was given in the RIA than in the EIA. A further 110 patients with various illnesses were examined for serum CEA-levels using RIA. A method for measuring CEA in feces by RIA was developed. The normal range lies below 300 ng/ml. This assay could be of significance for the early recognition of colo-rectal carcinoma. In part II of this dissertation CEA was isolated from colo-rectal carcinomas using three different gel filtration media. It was only possible to obtain almost pure CEA (24 μg CEA per μg protein) by one of the methods. Six guinea pigs were immunized with the isolated CEA and all developed antibodies. The isolated CEA was labelled with 125 I and an own RIA saturation sequence and double antibody separation was developed. One of the antisera was able to distinguish without overlap 7 healthy patients from 7 suffering from colo-rectal carcinomas in non-extracted serum. (orig./MG) [de

  20. A scenario analysis of future energy systems based on an energy flow model represented as functionals of technology options

    International Nuclear Information System (INIS)

    Kikuchi, Yasunori; Kimura, Seiichiro; Okamoto, Yoshitaka; Koyama, Michihisa

    2014-01-01

    Highlights: • Energy flow model was represented as the functionals of technology options. • Relationships among available technologies can be visualized by developed model. • Technology roadmapping can be incorporated into the model as technical scenario. • Combination of technologies can increase their contribution to the environment. - Abstract: The design of energy systems has become an issue all over the world. A single optimal system cannot be suggested because the availability of infrastructure and resources and the acceptability of the system should be discussed locally, involving all related stakeholders in the energy system. In particular, researchers and engineers of technologies related to energy systems should be able to perform the forecasting and roadmapping of future energy systems and indicate quantitative results of scenario analyses. We report an energy flow model developed for analysing scenarios of future Japanese energy systems implementing a variety of feasible technology options. The model was modularized and represented as functionals of appropriate technology options, which enables the aggregation and disaggregation of energy systems by defining functionals for single technologies, packages integrating multi-technologies, and mini-systems such as regions implementing industrial symbiosis. Based on the model, the combinations of technologies on both energy supply and demand sides can be addressed considering not only the societal scenarios such as resource prices, economic growth and population change but also the technical scenarios including the development and penetration of energy-related technologies such as distributed solid oxide fuel cells in residential sectors and new-generation vehicles, and the replacement and shift of current technologies such as heat pumps for air conditioning and centralized power generation. The developed model consists of two main modules; namely, a power generation dispatching module for the

  1. Research and development project for a large-scale industrial technology in fiscal 1992. Research and development of an advanced function creating and processing technology /Development of an advanced function creating and processing technology (Report on work achievements); 1992 nend senshin kino soshutsu kako gijutsu no kenkyu kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-01-01

    A joint research has been performed between the Material Engineering Technology Research Institute of the National Institute of Materials and Chemical Research of the Ministry of International Trade and Industry and the Advanced Function Creating and Processing Technology Research Association. The research themes are the 'identification of the basic conditions for production of ultra fine ceramics particles by using the hybrid high-frequency plasma process' and the 'establishment of non-destructive analysis technology for inclination functional materials'. This paper reports the achievements in fiscal 1992. The research on the inclination functional materials has performed hybridization of high-frequency plasmas and fabrication of ultra fine alumina particles, trial fabrication and evaluation on alumina-titanium mixed ultra fine particles by using the high-frequency plasma process, spraying of hydroxyapatite by using high-frequency plasma, evaluation on thick film bulk made of ultra fine particles, and trial fabrication of an ultra fine particle injection device. It was intended to evaluate quantitatively crystalline deficiency and composition distribution in the inclination functional materials for which continuous composition control is important. Therefore, a Rutherford wake scattering device was introduced and installed newly at the Material Engineering Technology Research Institute, which has improved the evaluation and experiment system at the institute. (NEDO)

  2. Fiscal 1997 technological survey report. R and D on micromachine technology (Development of high functional maintenance technology for power station equipment); 1997 nendo micromachine gijutsu no kenkyu kaihatsu seika hokokusho. Hatsuden shisetsuyo kokino maintenance gijutsu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    Activities were conducted in search of micromachine technology for a high functional maintenance system that inspects and repairs abnormal conditions such as cracks in a heat exchanger or a piping system without disassembling it in a power generating station such as a thermal or nuclear power plant. The activities were proceeded in four areas of (1) experimental manufacturing of the system (an inline self-running environment recognizing system, an external inspection system for fine tube group, and a system capable of light internal operation such as welding), (2) R and D on sophistication technology for functional devices, (3) R and D on common basic technologies, and (4) comprehensive investigation and research. In (1), examination of detailed basic specifications was carried out, as were examination of element technologies, experimental manufacturing and operation test of element devices, and performance evaluation. Further, a part of element devices was made on an experimental basis, with the basic functions demonstrated. In the comprehensive investigation and research, a trend in the future maintenance technology in power generating equipment was obtained and pigeonholed. (NEDO)

  3. Dynamics of serum testosterone during the menstrual cycle evaluated by daily measurements with an ID-LC-MS/MS method and a 2nd generation automated immunoassay

    NARCIS (Netherlands)

    Bui, Hong N.; Sluss, Patrick M.; Blincko, Stuart; Knol, Dirk L.; Blankenstein, Marinus A.; Heijboer, Annemieke C.

    2013-01-01

    Testosterone concentrations in normally cycling women are assumed to be elevated around the time of ovulation. The clinical relevance of changing testosterone concentrations during the menstrual cycle, however, is unclear. Poor performance of current direct immunoassays for testosterone at low

  4. A Nanoparticle-Lectin Immunoassay Improves Discrimination of Serum CA125 from Malignant and Benign Sources.

    Science.gov (United States)

    Gidwani, Kamlesh; Huhtinen, Kaisa; Kekki, Henna; van Vliet, Sandra; Hynninen, Johanna; Koivuviita, Niina; Perheentupa, Antti; Poutanen, Matti; Auranen, Annika; Grenman, Seija; Lamminmäki, Urpo; Carpen, Olli; van Kooyk, Yvette; Pettersson, Kim

    2016-10-01

    Measurement of serum cancer antigen 125 (CA125) is the standard approach for epithelial ovarian cancer (EOC) diagnostics and follow-up. However, the clinical specificity is not optimal because increased values are also detected in healthy controls and in benign diseases. CA125 is known to be differentially glycosylated in EOC, potentially offering a way to construct CA125 assays with improved cancer specificity. Our goal was to identify carbohydrate-reactive lectins for discriminating between CA125 originating from EOC and noncancerous sources. CA125 from the OVCAR-3 cancer cell line, placental homogenate, and ascites fluid from patients with cirrhosis were captured on anti-CA125 antibody immobilized on microtitration wells. A panel of lectins, each coated onto fluorescent europium-chelate-doped 97-nm nanoparticles (Eu(+3)-NPs), was tested for detection of the immobilized CA125. Serum samples from high-grade serous EOC or patients with endometriosis and healthy controls were analyzed. By using macrophage galactose-type lectin (MGL)-coated Eu(+3)-NPs, an analytically sensitive CA125 assay (CA125(MGL)) was achieved that specifically recognized the CA125 isoform produced by EOC, whereas the recognition of CA125 from nonmalignant conditions was reduced. Serum CA125(MGL) measurement better discriminated patients with EOC from endometriosis compared to conventional immunoassay. The discrimination was particularly improved for marginally increased CA125 values and for earlier detection of EOC progression. The new CA125(MGL) assay concept could help reduce the false-positive rates of conventional CA125 immunoassays. The improved analytical specificity of this test approach is dependent on a discriminating lectin immobilized in large numbers on Eu(+3)-NPs, providing both an avidity effect and signal amplification. © 2016 American Association for Clinical Chemistry.

  5. Mobile Phone Ratiometric Imaging Enables Highly Sensitive Fluorescence Lateral Flow Immunoassays without External Optical Filters.

    Science.gov (United States)

    Shah, Kamal G; Singh, Vidhi; Kauffman, Peter C; Abe, Koji; Yager, Paul

    2018-05-14

    Paper-based diagnostic tests based on the lateral flow immunoassay concept promise low-cost, point-of-care detection of infectious diseases, but such assays suffer from poor limits of detection. One factor that contributes to poor analytical performance is a reliance on low-contrast chromophoric optical labels such as gold nanoparticles. Previous attempts to improve the sensitivity of paper-based diagnostics include replacing chromophoric labels with enzymes, fluorophores, or phosphors at the expense of increased fluidic complexity or the need for device readers with costly optoelectronics. Several groups, including our own, have proposed mobile phones as suitable point-of-care readers due to their low cost, ease of use, and ubiquity. However, extant mobile phone fluorescence readers require costly optical filters and were typically validated with only one camera sensor module, which is inappropriate for potential point-of-care use. In response, we propose to couple low-cost ultraviolet light-emitting diodes with long Stokes-shift quantum dots to enable ratiometric mobile phone fluorescence measurements without optical filters. Ratiometric imaging with unmodified smartphone cameras improves the contrast and attenuates the impact of excitation intensity variability by 15×. Practical application was shown with a lateral flow immunoassay for influenza A with nucleoproteins spiked into simulated nasal matrix. Limits of detection of 1.5 and 2.6 fmol were attained on two mobile phones, which are comparable to a gel imager (1.9 fmol), 10× better than imaging gold nanoparticles on a scanner (18 fmol), and >2 orders of magnitude better than gold nanoparticle-labeled assays imaged with mobile phones. Use of the proposed filter-free mobile phone imaging scheme is a first step toward enabling a new generation of highly sensitive, point-of-care fluorescence assays.

  6. Comparison of serum HBsAg quantitation by four immunoassays, and relationships of HBsAg level with HBV replication and HBV genotypes.

    Directory of Open Access Journals (Sweden)

    Edouard Tuaillon

    Full Text Available BACKGROUND: The decline in hepatitis B virus surface antigen (HBsAg may be an early predictor of the viral efficacy of Hepatitis B virus (HBV therapy. The HBsAg levels obtained by different immunoassays now need comparing and the relationships between levels of HBsAg and HBV DNA alongside HBsAg and genotype must be evaluated. METHODOLOGY/PRINCIPAL FINDINGS: HBsAg levels were compared among 80 patients using the Abbott Architect assay, a commercial immunoassay approved for HBsAg detection and quantitation, and three other assays derived from immunoassays approved for HBsAg detection (manufactured by Diasorin, Bio-Rad and Roche. Good correlation was found between the Abbot vs. Diasorin, Bio-Rad and Roche assays with narrow 95% limits of agreement and small mean differences: -0.06 to 0.11, -0.09 log(10 IU/mL; -0.57 to 0.64, -0.04 log(10 IU/mL; -0.09 to 0.45, -0.27 log(10 IU/mL, respectively. These agreements were not affected by genotypes A or D. HBsAg was weakly correlated with HBV DNA, whatever the HBsAg assay used: Abbott, ρ = 0.36 p = 0.001, Diasorin ρ = 0.34, p = 0.002; Bio-Rad ρ = 0.37, p<0.001; or Roche ρ = 0.41, p<0.001. This relationship between levels of HBsAg and HBV DNA seemed to depend on genotypes. Whereas HBsAg (Abbott assay tended to correlate with HBV DNA for genotype A (ρ = 0.44, p = 0.02, no such correlation was significant for genotypes D (ρ = 0.29, p = 0.15. CONCLUSION/SIGNIFICANCE: The quantitation of HBsAg in routine clinical samples is comparable between the reference assay and the adapted assays with acceptable accuracy limits, low levels of variability and minimum discrepancy. While HBsAg quantitation is not affected by HBV genotype, the observed association between levels of HBsAg and HBV DNA seems genotype dependent.

  7. Time-Resolved Analysis of a Highly Sensitive Förster Resonance Energy Transfer Immunoassay Using Terbium Complexes as Donors and Quantum Dots as Acceptors

    Directory of Open Access Journals (Sweden)

    Niko Hildebrandt

    2007-01-01

    Full Text Available CdSe/ZnS core/shell quantum dots (QDs are used as efficient Förster Resonance Energy Transfer (FRET acceptors in a time-resolved immunoassays with Tb complexes as donors providing a long-lived luminescence decay. A detailed decay time analysis of the FRET process is presented. QD FRET sensitization is evidenced by a more than 1000-fold increase of the QD luminescence decay time reaching ca. 0.5 milliseconds, the same value to which the Tb donor decay time is quenched due to FRET to the QD acceptors. The FRET system has an extremely large Förster radius of approx. 100 Å and more than 70% FRET efficiency with a mean donor-acceptor distance of ca. 84 Å, confirming the applied biotin-streptavidin binding system. Time-resolved measurement allows for suppression of short-lived emission due to background fluorescence and directly excited QDs. By this means a detection limit of 18 attomol QDs within the immunoassay is accomplished, an improvement of more than two orders of magnitude compared to commercial systems.

  8. Novel approaches in food-processing technology: new technologies for preserving foods and modifying function.

    Science.gov (United States)

    Knorr, D

    1999-10-01

    Recent advances in emerging food-processing technologies, such as high hydrostatic pressure or high-intensity electric field pulses, allow targeted and sophisticated modification and preservation of foods. We are beginning to understand the mechanisms involved in pressure inactivation of bacterial spores and have been collecting considerable amounts of kinetic data regarding inactivation mechanisms of enzymes and vegetative microorganisms. We are also gaining more insight into the permeabilization of plant membranes and related biosynthetic responses, making progress in food structure engineering and food modification for function, and have been initiating process developments for gentle processing of delicate biomaterials based on pressure-assisted phase transitions of water.

  9. Techno-functional differentiation of two vitamin B12 producing Lactobacillus plantarum strains: an elucidation for diverse future use.

    Science.gov (United States)

    Bhushan, Bharat; Tomar, S K; Chauhan, Arun

    2017-01-01

    An appropriate selection of Lactobacillus strain (probiotic/starter/functional) on the basis of its techno-functional characteristics is required before developing a novel fermented functional food. We compared vitamin B 12 (B 12 , cobalamin) producing Lactobacillus plantarum isolates, BHM10 and BCF20, for functional (vitamin over-production, genomic insight to B 12 structural genes, and probiotic attributes) and technological [milks (skim and soy) fermentation and B 12 bio-fortification] characteristics. Addition of B 12 precursors (5-amonolevulinate and dimethylbenzimidazole) to cobalamin-free fermentation medium increased vitamin production in BHM10, BCF20, and DSM20016 (a positive standard) by 3.4-, 4.4-, and 3.86-folds, respectively. Three important B 12 structural genes were detected in L. plantarum species (strains BHM10 and BCF20) by PCR for the first time. The gene sequences were submitted to NCBI GenBank and found phylogenetically closer to respective sequences in B 12 producing Lactobacillus reuteri strains. During comparative probiotic testing, BCF20 showed significantly higher (p < 0.05 to p < 0.001) gastrointestinal tolerance and cell surface hydrophobicity (p < 0.05) than BHM10. Moreover, only BCF20 was found positive for BSH activity and also exhibited comparatively better antagonistic potential against potent pathogens. Conversely, high acid and bile susceptible strain BHM10 displayed significantly higher soy milk fermentation and resultant B 12 bio-fortification abilities during technological testing. Two B 12 quantification techniques, UFLC and competitive immunoassay, confirmed the in vitro and in situ bio-production of bio-available form of B 12 after BHM10 fermentation. Conclusively, techno-functional differentiation of two B 12 producing strains elucidates their diverse future use; BCF20 either for B 12 over-production (in vitro) or as a probiotic candidate, while BHM10 for cobalamin bio-fortification (in situ) in soy milk.

  10. Validation of an enzyme-immunoassay for the non-invasive monitoring of faecal testosterone metabolites in male cheetahs (Acinonyx jubatus).

    Science.gov (United States)

    Pribbenow, Susanne; Wachter, Bettina; Ludwig, Carsten; Weigold, Annika; Dehnhard, Martin

    2016-03-01

    In mammals, the sex hormone testosterone is the major endocrine variable to objectify testicular activity and thus reproductive function in males. Testosterone is involved in the development and function of male reproductive physiology and sex-related behaviour. The development of a reliable androgen enzyme-immunoassay (EIA) to monitor faecal testosterone metabolites (fTM) is a powerful tool to non-invasively assess the gonadal status of males. We validated an epiandrosterone EIA for male cheetahs by performing a testosterone radiometabolism study followed by high-performance liquid chromatography (HPLC) analyses and excluding possible cross-reactivities with androgenic metabolites not derived from testosterone metabolism. The physiological and biological relevance of the epiandrosterone EIA was validated by demonstrating (1) a significant increase in fTM concentrations within one day in response to a testosterone injection, (2) a significant increase in fTM concentrations within one day in response to a gonadotropin-releasing hormone (GnRH) injection, which failed following a placebo injection, and (3) significant differences in fTM concentrations between adult male and adult female cheetahs and between adult and juvenile male cheetahs of a free-ranging population. Finally, we demonstrated stability of fTM concentrations measured in faecal samples exposed to ambient temperatures up to 72h. Our results clearly demonstrate that the epiandrosterone EIA is a reliable non-invasive method to monitor testicular activity in male cheetahs. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Optimization of condition for conjugation of enrofloxacin to enzymes in chemiluminescence enzyme immunoassay

    Science.gov (United States)

    Yu, Songcheng; Yu, Fei; Zhang, Hongquan; Qu, Lingbo; Wu, Yongjun

    2014-06-01

    In this study, in order to find out a proper method for conjugation of enrofloxacin to label enzymes, two methods were compared and carbodiimide condensation was proved to be better. The results showed that the binding ratio of enrofloxacin and alkaline phosphatase (ALP) was 8:1 and that of enrofloxacin and horseradish peroxidase (HRP) was 5:1. This indicated that conjugate synthesized by carbodiimide condensation was fit for chemiluminescence enzyme immunoassay (CLEIA). Furthermore, data revealed that dialysis time was an important parameter for conjugation and 6 days was best. Buffer to dilute conjugate had little effect on CLEIA. The storage condition for conjugates was also studied and it was shown that the conjugate was stable at 4 °C with no additive up to 30 days. These data were valuable for establishing CLEIA to quantify enrofloxacin.

  12. Novel electrochemical redox-active species: one-step synthesis of polyaniline derivative-Au/Pd and its application for multiplexed immunoassay

    Science.gov (United States)

    Wang, Liyuan; Feng, Feng; Ma, Zhanfang

    2015-11-01

    Electrochemical redox-active species play crucial role in electrochemically multiplexed immunoassays. A one-pot method for synthesizing four kinds of new electrochemical redox-active species was reported using HAuCl4 and Na2PdCl4 as dual oxidating agents and aniline derivatives as monomers. The synthesized polyaniline derivative-Au/Pd composites, namely poly(N-methyl-o-benzenediamine)-Au/Pd, poly(N-phenyl-o-phenylenediamine)-Au/Pd, poly(N-phenyl-p-phenylenediamine)-Au/Pd and poly(3,3’,5,5’-tetramethylbenzidine)-Au/Pd, exhibited electrochemical redox activity at -0.65 V, -0.3 V, 0.12 V, and 0.5 V, respectively. Meanwhile, these composites showed high H2O2 electrocatalytic activity because of the presence of Au/Pd. The as-prepared composites were used as electrochemical immunoprobes in simultaneous detection of four tumor biomarkers (carcinoembryonic antigen (CEA), carbohydrate antigen 19-9 (CA199), carbohydrate antigen 72-4 (CA724), and alpha fetoprotein (AFP)). This immunoassay shed light on potential applications in simultaneous gastric cancer (related biomarkers: CEA, CA199, CA724) and liver cancer diagnosis (related biomarkers: CEA, CA199, AFP). The present strategy to the synthesize redox species could be easily extended to other polymers such as polypyrrole derivatives and polythiophene derivatives. This would be of great significance in the electrochemical detection of more analytes.

  13. A novel nano-immunoassay method for quantification of proteins from CD138-purified myeloma cells: biological and clinical utility.

    Science.gov (United States)

    Misiewicz-Krzeminska, Irena; Corchete, Luis Antonio; Rojas, Elizabeta A; Martínez-López, Joaquín; García-Sanz, Ramón; Oriol, Albert; Bladé, Joan; Lahuerta, Juan-José; Miguel, Jesús San; Mateos, María-Victoria; Gutiérrez, Norma C

    2018-05-01

    Protein analysis in bone marrow samples from patients with multiple myeloma has been limited by the low concentration of proteins obtained after CD138 + cell selection. A novel approach based on capillary nano-immunoassay could make it possible to quantify dozens of proteins from each myeloma sample in an automated manner. Here we present a method for the accurate and robust quantification of the expression of multiple proteins extracted from CD138-purified multiple myeloma samples frozen in RLT Plus buffer, which is commonly used for nucleic acid preservation and isolation. Additionally, the biological and clinical value of this analysis for a panel of 12 proteins essential to the pathogenesis of multiple myeloma was evaluated in 63 patients with newly diagnosed multiple myeloma. The analysis of the prognostic impact of CRBN /Cereblon and IKZF1 /Ikaros mRNA/protein showed that only the protein levels were able to predict progression-free survival of patients; mRNA levels were not associated with prognosis. Interestingly, high levels of Cereblon and Ikaros proteins were associated with longer progression-free survival only in patients who received immunomodulatory drugs and not in those treated with other drugs. In conclusion, the capillary nano-immunoassay platform provides a novel opportunity for automated quantification of the expression of more than 20 proteins in CD138 + primary multiple myeloma samples. Copyright © 2018 Ferrata Storti Foundation.

  14. Rapid and Low-Cost CRP Measurement by Integrating a Paper-Based Microfluidic Immunoassay with Smartphone (CRP-Chip)

    Science.gov (United States)

    Dong, Meili; Wu, Jiandong; Ma, Zimin; Peretz-Soroka, Hagit; Zhang, Michael; Komenda, Paul; Tangri, Navdeep; Liu, Yong; Rigatto, Claudio; Lin, Francis

    2017-01-01

    Traditional diagnostic tests for chronic diseases are expensive and require a specialized laboratory, therefore limiting their use for point-of-care (PoC) testing. To address this gap, we developed a method for rapid and low-cost C-reactive protein (CRP) detection from blood by integrating a paper-based microfluidic immunoassay with a smartphone (CRP-Chip). We chose CRP for this initial development because it is a strong biomarker of prognosis in chronic heart and kidney disease. The microfluidic immunoassay is realized by lateral flow and gold nanoparticle-based colorimetric detection of the target protein. The test image signal is acquired and analyzed using a commercial smartphone with an attached microlens and a 3D-printed chip–phone interface. The CRP-Chip was validated for detecting CRP in blood samples from chronic kidney disease patients and healthy subjects. The linear detection range of the CRP-Chip is up to 2 μg/mL and the detection limit is 54 ng/mL. The CRP-Chip test result yields high reproducibility and is consistent with the standard ELISA kit. A single CRP-Chip can perform the test in triplicate on a single chip within 15 min for less than 50 US cents of material cost. This CRP-Chip with attractive features of low-cost, fast test speed, and integrated easy operation with smartphones has the potential to enable future clinical PoC chronic disease diagnosis and risk stratification by parallel measurements of a panel of protein biomarkers. PMID:28346363

  15. The clinical value of enzyme-multiplied immunoassay technique monitoring the plasma concentrations of cyclosporine A after renal transplantation

    Directory of Open Access Journals (Sweden)

    Xiao-Hui Luo

    2011-05-01

    Full Text Available The feasibility and the clinical value of the enzyme-multiplied immunoassay technique (EMIT monitoring of blood concentrations of cyclosporine A (CsA in patients treated with CsA were investigated after kidney transplantation. The validation method was performed to the EMIT determination of CsA blood concentration, the CsA whole blood ‘trough concentrations (C0 of patients in different time periods after renal transplantation were monitored, and combined with the clinical complications, the statistical results were analyzed and compared. EMIT was precise, accurate and stable, also with a high quality control. The mean postoperative blood concentration of CsA was as follows: 12 months, (185.6 ± 28.1ng/mL. The toxic reaction rate of CsA blood concentration within the recommended therapeutic concentration was 14. 1%, significantly lower than that of the none-recommended dose group (37.2% (P < 0.05; the transplantation rejection rate was 4.4%, significantly lower than that of the none-recommended dose group (22.5% (P < 0.05. Using EMIT to monitor the blood concentration of CsA as the routine laboratory method is feasible, and is able to reduce the CsA toxicity and rejection significantly, leading to achieving the desired therapeutic effect. Keywords: enzyme-multiplied immunoassay technique, renal transplantation, cyclosporin A, blood concentration monitoring

  16. Enzyme immunoassays for the diagnosis of bovine brucellosis. Trial in Latin America

    International Nuclear Information System (INIS)

    Gall, D.; Nielsen, K.; Colling, A.; Marino, O.; Moreno, E.; Perez, B.; Samartino, L.

    1998-01-01

    The results of a field trail conducted in Latin America with two indirect (IELISA) and two competitive (CELISA) enzyme immunoassays for the detection of bovine antibody to Brucella abortus are reported. One of the CELISA formats performed most accurately. The relative sensitivity of this assay was 97.47%, the relative specificity for unexposed cattle was 98.32% and the specificity in cattle vaccinated with B. abortus strain 19 was 96.51%. The same assay format under Canadian conditions had a sensitivity of 100%, a specificity of 99.90% and a specificity of 97.7% in a strain 19 vaccinated population. Overall, the CELISA performed as expected and the results were not dissimilar to the results obtained in the Canadian study thus providing further evidence that this CELISA can in many instances differentiate infected cattle from those that are vaccinated or infected with a cross-reacting organism while still giving very low false positive or false negative results. (author)

  17. Development of a chip-based multiplexed immunoassay using liposomal nanovesicles and its application in the detection of pathogens causing female lower genital tract infections

    Directory of Open Access Journals (Sweden)

    Wen-Hsiang Su

    2013-03-01

    Conclusion: This microarray chip was a rapid, easy, inexpensive and sensitive tool for detecting female lower genital tract Candida infection in a one-time vaginal sampling process, although the data on the four other pathogens were still unavailable. A larger population study is encouraged to test the validity of this multiplexed immunoassay chip.

  18. Research on energy-saving effect of technological progress based on Cobb-Douglas production function

    International Nuclear Information System (INIS)

    Yuan Chaoqing; Liu Sifeng; Wu Junlong

    2009-01-01

    Energy issues receive more and more attention these days. And it is considered that technological progress is an essential approach to save energy. This essay is to analyze the relation between energy intensity and technological progress by Cobb-Douglas production function in which energy, labor, capital and technological progress are taken as independent variables. It proves that the growth of output per capital and output per labor will increase energy intensity while technological progress will decrease energy intensity. Empirical research on Chinese industry is used here to indicate technological progress greatly decreases energy intensity. Because of the interferences of Asian financial crisis, there is something abnormal in the data. So in the empirical research, average weaken buffer operator (ABWO) is applied to weaken the interference of Asian financial crisis to the fixed assets, energy and value added. The results of the empirical research show that technological progress decreases energy intensity of Chinese industry an average of 6.3% every year in China.

  19. Fiscal 1999 project for research and development of industrial and scientific technologies. Report on the achievements on research and development of a technology to structure accelerated type living organism functions (Research on a technology to create a new type high-function enzyme); 1999 nendo kosokugata seibutsu kino kochiku gijutsu no kenkyu kaihatsu seika hokokusho. Shingata kokino koso sosei gijutsu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    With an aim at structuring an advancement experimental system that can introduce high-level functions efficiently, development was made on a technology to create new type high-function enzymes. This paper summarizes the achievements in fiscal 1999. In the research of a mutation generating technology, application of the DNA shuffling technology was attempted onto phenol hydroxide enzymes and 2,3-dihydroxybiphenyl 1,2-oxygen added enzymes to discuss the possibility of decomposition of trichloroethylene and decomposition of PCB. In the research of a technology to provide gene type and expression type correspondence, improvement in the vector was studied to increase manifestation of motifs onto bacteria surface so that high-sensitivity detection may be made even on a very small amount of a substance. In the research of an efficient selection technology, studies were made on the catalytic function selecting system and the information function selecting system. In the research of an adaptive walking technology, studies were made on REP, LOD, the advancement experimental system using interaction between proteins as the adaptability, and the multi-dimensional adaptive walking technology. In comprehensive surveys and studies, technological information was exchanged, and discussion meetings were held. (NEDO)

  20. Exploiting fluorescence for multiplex immunoassays on protein microarrays

    International Nuclear Information System (INIS)

    Herbáth, Melinda; Balogh, Andrea; Matkó, János; Papp, Krisztián; Prechl, József

    2014-01-01

    Protein microarray technology is becoming the method of choice for identifying protein interaction partners, detecting specific proteins, carbohydrates and lipids, or for characterizing protein interactions and serum antibodies in a massively parallel manner. Availability of the well-established instrumentation of DNA arrays and development of new fluorescent detection instruments promoted the spread of this technique. Fluorescent detection has the advantage of high sensitivity, specificity, simplicity and wide dynamic range required by most measurements. Fluorescence through specifically designed probes and an increasing variety of detection modes offers an excellent tool for such microarray platforms. Measuring for example the level of antibodies, their isotypes and/or antigen specificity simultaneously can offer more complex and comprehensive information about the investigated biological phenomenon, especially if we take into consideration that hundreds of samples can be measured in a single assay. Not only body fluids, but also cell lysates, extracted cellular components, and intact living cells can be analyzed on protein arrays for monitoring functional responses to printed samples on the surface. As a rapidly evolving area, protein microarray technology offers a great bulk of information and new depth of knowledge. These are the features that endow protein arrays with wide applicability and robust sample analyzing capability. On the whole, protein arrays are emerging new tools not just in proteomics, but glycomics, lipidomics, and are also important for immunological research. In this review we attempt to summarize the technical aspects of planar fluorescent microarray technology along with the description of its main immunological applications. (topical review)

  1. Measurements in international units of antibody to hepatitis B surface antigen(anti-HBs) after immunization with a yeast-derived, subtype adr hepatitis B vaccine are considerably different between chemiluminescent immunoassay (CLIA) and chemiluminescent enzyme immunoassay (CLEIA).

    Science.gov (United States)

    Ogata, Norio

    2006-04-01

    The worldwide consensus of the minimum protective anti-HBs level against HBV infection is 10 mIU/mL on assays standardized by the World Health Organization (WHO) reference preparations. To investigate whether this value could be applied to recipients of yeast-derived recombinant HB vaccine containing the major surface protein of subtype adr (Bimmugen, Astellas Pharmaceutical, Tokyo), we compared anti-HBs measurements between chemiluminescent immunoassay (CLIA) (Architect Ausab, Abbott Japan, Tokyo) and chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse Forte, Fujirebio, Tokyo) in given serum samples obtained from the vaccinees. The vaccine and the two assay methods are currently in a wide use in Japan. The study included 300 medical students who completed a standard vaccination course (0, 1 and 6 months). Serum samples obtained 1 month or 13 months after completing the vaccination were simultaneously tested for anti-HBs by CLIA and CLEIA. In 147 samples with quantifiable values on both CLIA and CLEIA (10 to 1000 mIU/mL) the geometric mean titer on CLEIA (225.0 mIU/mL) was significantly higher than that on CLIA (94.5 mIU/mL) (p < 0.0001). Of 26 subjects with CLIA measurements below 10 mIU/mL, 15 samples (57.7%) showed CLEIA measurements more than 10 mIU/mL. Thus, in the subtype adr-vaccinees CLEIA demonstrated considerably high serum anti-HBs measurements compared to CLIA and discordance in determining critical anti-HBs level of 10 mIU/mL was observed in more than half the samples. This suggests that the minimum HBV-protective anti HBs titer of 10 mIU/mL is difficult to be introduced to Japan where subtype adr-HB vaccines or -HBV infection are prevalent, unless characteristics of assay methods are carefully evaluated.

  2. SYNERGY OF INFORMATION COMMUNICATION TECHNOLOGIES AND THE BANKING SYSTEM IN THE FUNCTIONING OF SUCCESSFUL BANKING OPERATIONS

    Directory of Open Access Journals (Sweden)

    Dario Kovačević

    2017-01-01

    Full Text Available Nowadays, modern banking cannot function without information and communications technology; hence banks heavily invest in the implementation of technology currently present on the market. Every aspect of the banking business includes information and communications technology, which points to the necessity of building an infrastructure for modern banking. Investing in development and implementation of new technologies simplifies everyday business activities and security, in addition to creating a competitive edge over rival businesses. It ensures fast and efficient customer service delivery by providing support to the distribution channels, as well as supporting bankers with making crucial decisions. The aim of this paper is to analyse trends in the use of information and communications technologies in the banking system, using publicly available business data, documentation and online bank information, as well as previously published findings of other researchers. Using the example of one of the largest banks in the Republic of Croatia, the possibilities provided by information and communications technology in the banking business sector are illustrated. Additionally, better economic efficiency and effectiveness, as well as the means of contemporary bank functioning are presented. Special attention is devoted to the security of ICT systems used in Internet Banking and the protection of banking service users’ data.

  3. A methodology for financial evaluation of biogas technology in India using cost functions

    International Nuclear Information System (INIS)

    Rubab, S.; Kandpal, T.C.

    1996-01-01

    A methodology for financial evaluation of biogas technology for domestic use in India using recently developed cost functions is reported. Analytical expressions for the unit cost of biogas and cost per unit of useful energy delivered by a biogas plant in combination with other suitable technologies have been developed. Net present value and discounted pay-back period have been calculated. The sensitivity of the unit cost of biogas, the cost per unit of useful energy, and the net present value with respect to a number of variables is also reported. (author)

  4. Basic and clinical investigation of T3 immunoassay kit

    International Nuclear Information System (INIS)

    Konishi, Junji; Nakajima, Akiko; Morita, Rikushi; Endo, Keigo; Ikekubo, Katsuji

    1976-01-01

    T 3 immunoassay kit was investigated basically and clinically. A good result was obtained at the prescribed incubation temperature and for 16 hours of incubation time. Moreover, it was thought to be possible that incubation time could be shortened to 1 - 4 hours at 37 0 C. Specificity of antibody was good. Recovery of added T 3 was 100+-5 (S.D.) % on an average and parallel of dilution curve of high T 3 serum was also good. Variation coefficient of accuracy of this kit was 1.5 - 2.1 % and that of reproducibility was 1.3 - 6.6 %. Mild hemolysis did not affect measurement value. Serum T 3 level in normals, untreated patients with Basedow's disease and patients with primary hypothyroidism was 142+-21 ng/100 ml, 452+-156 ng/100 ml and 67+-17 ng/100 ml, respectively. Serum T 3 level in patients with Hashimoto's disease was distributed to a wide extent, but that of patients with goiter and simple goiter ranged within normal range. On the other side, serum T 3 level of normal pregnant woman was high and that of patients with anorexia nervosa showed low level. From the above mentioned results, it was concluded that this kit was simple in method and good in sensitivity, specificity and reproducibility and it was also useful for clinical applications. (M. Tsunoda)

  5. Erythema migrans and serodiagnosis by enzyme immunoassay and immunoblot with three borrelia species.

    Science.gov (United States)

    Stanek, G; Breier, F; Menzinger, G; Schaar, B; Hafner, M; Partsch, H

    1999-12-10

    There is wide divergence of opinion between physicians regarding the use of serological measures for the diagnosis and treatment of erythema migrans, the hallmark of Lyme borreliosis. We studied the outcome of an enzyme immunoassay and immunoblot (Western blot) used on the sera of patients who had suffered tick bite and erythema migrans, and had been subsequently treated with various antibiotics. Ninety-nine consecutive patients presenting with erythema migrans after tick bite were prospectively recruited at the outpatient department of two Vienna City hospitals and at the consultation office for Lyme borreliosis of the Institute of Hygiene. University Vienna. Blood samples were taken before antibiotic treatment and 3 and 6 months thereafter. Blood samples from 100 blood donors served as controls. Antibodies against Borrelia burgdorferi sensu lato were determined by enzyme immunoassay (IgG and IgM EIA) and by IgG immunoblot. The latter was performed with isolates of B. alzelii (H2) B. burgdorferi sensu stricto (Le) and B. garinii (W) from Austrian patients. The 4 interpretation criteria for immunoblot results were: A (3 bands out of 8), B (2 bands out of 9), C and D (1 band out of 6). In all patients, the erythema resolved within the treatment period. No complications secondary to the borrelia infection were registered. After treatment there was no significant change in titre, nor was there a difference in the immunoblot pattern between the first, second and third serum samples. Serum antibodies to B. burgdorferi were positive by EIA in 22.9% (IgG) and 2.5% (IgM). Immunoblot results offered by borrelia species and by the interpretation criteria, ranging between 8.3% (criterion A, strain Le) and 44.2% (criterion D, strain H2). By EIA, control samples were IgG and IgM positive in 5% and 1%, respectively. Positive immunoblot results with strain H2 were found in 9%, 13%, 18%, and 20% by the criteria A through D respectively. After antibiotic treatment of erythema

  6. Implementation of workflow engine technology to deliver basic clinical decision support functionality.

    Science.gov (United States)

    Huser, Vojtech; Rasmussen, Luke V; Oberg, Ryan; Starren, Justin B

    2011-04-10

    Workflow engine technology represents a new class of software with the ability to graphically model step-based knowledge. We present application of this novel technology to the domain of clinical decision support. Successful implementation of decision support within an electronic health record (EHR) remains an unsolved research challenge. Previous research efforts were mostly based on healthcare-specific representation standards and execution engines and did not reach wide adoption. We focus on two challenges in decision support systems: the ability to test decision logic on retrospective data prior prospective deployment and the challenge of user-friendly representation of clinical logic. We present our implementation of a workflow engine technology that addresses the two above-described challenges in delivering clinical decision support. Our system is based on a cross-industry standard of XML (extensible markup language) process definition language (XPDL). The core components of the system are a workflow editor for modeling clinical scenarios and a workflow engine for execution of those scenarios. We demonstrate, with an open-source and publicly available workflow suite, that clinical decision support logic can be executed on retrospective data. The same flowchart-based representation can also function in a prospective mode where the system can be integrated with an EHR system and respond to real-time clinical events. We limit the scope of our implementation to decision support content generation (which can be EHR system vendor independent). We do not focus on supporting complex decision support content delivery mechanisms due to lack of standardization of EHR systems in this area. We present results of our evaluation of the flowchart-based graphical notation as well as architectural evaluation of our implementation using an established evaluation framework for clinical decision support architecture. We describe an implementation of a free workflow technology

  7. Implementation of workflow engine technology to deliver basic clinical decision support functionality

    Science.gov (United States)

    2011-01-01

    Background Workflow engine technology represents a new class of software with the ability to graphically model step-based knowledge. We present application of this novel technology to the domain of clinical decision support. Successful implementation of decision support within an electronic health record (EHR) remains an unsolved research challenge. Previous research efforts were mostly based on healthcare-specific representation standards and execution engines and did not reach wide adoption. We focus on two challenges in decision support systems: the ability to test decision logic on retrospective data prior prospective deployment and the challenge of user-friendly representation of clinical logic. Results We present our implementation of a workflow engine technology that addresses the two above-described challenges in delivering clinical decision support. Our system is based on a cross-industry standard of XML (extensible markup language) process definition language (XPDL). The core components of the system are a workflow editor for modeling clinical scenarios and a workflow engine for execution of those scenarios. We demonstrate, with an open-source and publicly available workflow suite, that clinical decision support logic can be executed on retrospective data. The same flowchart-based representation can also function in a prospective mode where the system can be integrated with an EHR system and respond to real-time clinical events. We limit the scope of our implementation to decision support content generation (which can be EHR system vendor independent). We do not focus on supporting complex decision support content delivery mechanisms due to lack of standardization of EHR systems in this area. We present results of our evaluation of the flowchart-based graphical notation as well as architectural evaluation of our implementation using an established evaluation framework for clinical decision support architecture. Conclusions We describe an implementation of

  8. Pseudosatellite technologies based on the use of functionally stable complexes of remote-piloted aircrafts

    Science.gov (United States)

    Mashkov, O. A.; Samborskiy, I. I.

    2009-10-01

    A bundle of papers dealing with functionally stable systems requires the necessity of analyzing of obtained results and their understanding in a general context of cybernetic's development and applications. Description of this field of science, main results and perspectives of the new theory of functionally stability of dynamical systems concerning the problem of remote-piloted aircrafts engineering using pseudosatellite technologies are proposed in the paper.

  9. Enzymatic amplification of a flow-injected thermometric enzyme-linked immunoassay for human insulin.

    Science.gov (United States)

    Mecklenburg, M; Lindbladh, C; Li, H; Mosbach, K; Danielsson, B

    1993-08-01

    A flow-injected thermometric enzyme linked immunoassay for human insulin which employs the lactate dehydrogenase/lactate oxidase (LDH/LOD) substrate recycling system for signal amplification is described. The system is composed of two columns, an immunosorbent column containing immobilized anti-insulin antibodies for sensing and a recycling column containing immobilized LDH/LOD/Catalase for detection. The effect of flow rates, conjugate concentrations, and chromatographic support material upon the sensitivity of the assay are investigated. The assay has a detection limit of 0.025 microgram/ml and a linear range from 0.05 to 2 micrograms/ml. This corresponds to a 10-fold increase in sensitivity over the unamplified system. A recombinant human insulin-proinsulin conjugate was also tested. The results show that enzymatic amplification can be employed to increase the sensitivity and reproducibility of flow injection assay-based biosensors. The implications of these results upon on-line analysis are discussed.

  10. Developments of sensitive immunoassays for detection of antibodies against hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Ionescu-Matiu, I; Sanchez, Y; Dreesman, G R [Baylor Univ., Houston, TX (USA). Coll. of Medicine; Fields, H A [Centers for Disease Control, Public Health Service, Department of Health and Human Services, Phoenix, AZ (USA)

    1983-01-01

    Three micro solid phase immunoassays (a micro-SPRIA and two ELISA techniques) were developed and tested for the detection of anti-HBs antibodies. Two different crosslinkers (glutaraldehyde and N-succinimidyl 3-(2-pyridyldithio) propionate) were used to couple a goat anti-mouse IgG reagent to alkaline phosphatase for use as enzyme-labeled probes in the two ELISA tests. With the latter cross-linker, a defined conjugate with a 1 : 1 antibody-enzyme molar ratio was obtained. The sensitivities of micro-SPRIA and the two types of ELISA were compared to that of the commercial solid phase radioimmunoassay AUSAB test. All three microtests were significantly more sensitive than the AUSAB test. The ELISA using the glutaraldehyde cross-linked conjugate was 3-5 times less sensitive than micro-SPRIA, while the ELISA using the disulfide-linked conjugate was 2.6-4.0 times more sensitive than micro-SPRIA.

  11. Morphometric Assessment of Convergent Tool Technology and Function during the Early Middle Palaeolithic: The Case of Payre, France.

    Science.gov (United States)

    Chacón, M Gema; Détroit, Florent; Coudenneau, Aude; Moncel, Marie-Hélène

    2016-01-01

    There appears to be little doubt as to the existence of an intentional technological resolve to produce convergent tools during the Middle Palaeolithic. However, the use of these pieces as pointed tools is still subject to debate: i.e., handheld tool vs. hafted tool. Present-day technological analysis has begun to apply new methodologies in order to quantify shape variability and to decipher the role of the morphology of these pieces in relation to function; for instance, geometric morphometric analyses have recently been applied with successful results. This paper presents a study of this type of analysis on 37 convergent tools from level Ga of Payre site (France), dated to MIS 8-7. These pieces are non-standardized knapping products produced by discoidal and orthogonal core technologies. Moreover, macro-wear studies attest to various activities on diverse materials with no evidence of hafting or projectile use. The aim of this paper is to test the geometric morphometric approach on non-standardized artefacts applying the Elliptical Fourier analysis (EFA) to 3D contours and to assess the potential relationship between size and shape, technology and function. This study is innovative in that it is the first time that this method, considered to be a valuable complement for describing technological and functional attributes, is applied to 3D contours of lithic products. Our results show that this methodology ensures a very good degree of accuracy in describing shape variations of the sharp edges of technologically non-standardized convergent tools. EFA on 3D contours indicates variations in deviations of the outline along the third dimension (i.e., dorso-ventrally) and yields quantitative and insightful information on the actual shape variations of tools. Several statistically significant relationships are found between shape variation and use-wear attributes, though the results emphasize the large variability of the shape of the convergent tools, which, in general

  12. Morphometric Assessment of Convergent Tool Technology and Function during the Early Middle Palaeolithic: The Case of Payre, France.

    Directory of Open Access Journals (Sweden)

    M Gema Chacón

    Full Text Available There appears to be little doubt as to the existence of an intentional technological resolve to produce convergent tools during the Middle Palaeolithic. However, the use of these pieces as pointed tools is still subject to debate: i.e., handheld tool vs. hafted tool. Present-day technological analysis has begun to apply new methodologies in order to quantify shape variability and to decipher the role of the morphology of these pieces in relation to function; for instance, geometric morphometric analyses have recently been applied with successful results. This paper presents a study of this type of analysis on 37 convergent tools from level Ga of Payre site (France, dated to MIS 8-7. These pieces are non-standardized knapping products produced by discoidal and orthogonal core technologies. Moreover, macro-wear studies attest to various activities on diverse materials with no evidence of hafting or projectile use. The aim of this paper is to test the geometric morphometric approach on non-standardized artefacts applying the Elliptical Fourier analysis (EFA to 3D contours and to assess the potential relationship between size and shape, technology and function. This study is innovative in that it is the first time that this method, considered to be a valuable complement for describing technological and functional attributes, is applied to 3D contours of lithic products. Our results show that this methodology ensures a very good degree of accuracy in describing shape variations of the sharp edges of technologically non-standardized convergent tools. EFA on 3D contours indicates variations in deviations of the outline along the third dimension (i.e., dorso-ventrally and yields quantitative and insightful information on the actual shape variations of tools. Several statistically significant relationships are found between shape variation and use-wear attributes, though the results emphasize the large variability of the shape of the convergent tools

  13. Simultaneous detection of IgG antibodies associated with viral hemorrhagic fever by a multiplexed Luminex-based immunoassay.

    Science.gov (United States)

    Wu, Wei; Zhang, Shuo; Qu, Jing; Zhang, Quanfu; Li, Chuan; Li, Jiandong; Jin, Cong; Liang, Mifang; Li, Dexin

    2014-07-17

    Viral hemorrhagic fevers (VHFs) are worldwide diseases caused by several kinds of viruses. With the emergence of new viruses, advanced diagnostic methods are urgently needed for identification of VHFs. Based on Luminex xMAP technology, a rapid, sensitive, multi-pathogen and high-throughput method which could simultaneously detect hemorrhagic fever viruses (HFVs) specific IgG antibodies was developed. Recombinant antigens of nine HFVs including Hantaan virus (HTNV), Seoul virus (SEOV), Puumala virus (PUUV), Andes virus (ANDV), Sin Nombre virus (SNV), Crimean-Congo hemorrhagic fever virus (CCHFV), Rift Valley fever virus (RVFV), Severe fever with thrombocytopenia syndrome bunyavirus (SFTSV) and dengue virus (DENV) were produced and purified from a prokaryotic expression system and the influence of the coupling amount was investigated. Cross-reactions among antigens and their rabbit immune sera were evaluated. Serum samples collected from 51 laboratory confirmed hemorrhagic fever with renal syndrome (HFRS) patients, 43 confirmed SFTS patients and 88 healthy donors were analyzed. Results showed that recombinant nucleocapsid protein of the five viruses belonging to the genus Hantavirus, had serological cross-reactivity with their corresponding rabbit immune sera, but not apparent with immune sera of other four viruses. Evaluation of this new method with clinical serum samples showed 98.04% diagnostic sensitivity for HFRS, 90.70% for SFTS detection and the specificity was ranging from 66.67% to 100.00%. The multiplexed Luminex-based immunoassay has firstly been established in our study, which provides a potentially reliable diagnostic tool for IgG antibody detection of VHFs. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Liposome-coated mesoporous silica nanoparticles loaded with L-cysteine for photoelectrochemical immunoassay of aflatoxin B1.

    Science.gov (United States)

    Lin, Youxiu; Zhou, Qian; Zeng, Yongyi; Tang, Dianping

    2018-06-02

    The authors describe a photoelectrochemical (PEC) immunoassay for determination of aflatoxin B 1 (AFB 1 ) in foodstuff. The competitive immunoreaction is carried out on a microplate coated with a capture antibody against AFB 1 using AFB 1 -bovine serum albumin (BSA)-liposome-coated mesoporous silica nanoparticles (MSN) loaded with L-cysteine as a support. The photocurrent is produced by a photoactive material consisting of cerium-doped Bi 2 MoO 6 . Initially, L-cysteine acting as the electron donor is gated in the pores by interaction between mesoporous silica and liposome. Thereafter, AFB 1 -BSA conjugates are covalently bound to the liposomes. Upon introduction of the analyte (AFB 1 ), the labeled AFB 1 -BSA complex competes with the analyte for the antibody deposited on the microplate. Accompanying with the immunocomplex, the liposomes on the MSNs are lysed upon addition of Triton X-100. This results in the opening of the pores and in a release of L-cysteine. Free cysteine then induces the electron-hole scavenger of the photoactive nanosheets to increase the photocurrent. The photocurrent (relative to background signal) increases with increasing AFB 1 concentration. Under optimum conditions, the photoactive nanosheets display good photoelectrochemical responses, and allow the detection of AFB 1 at a concentration as low as 0.1 pg·mL -1 within a linear response in the 0.3 pg·mL -1 to 10 ng·mL -1 concentration range. Accuracy was evaluated by analyzing naturally contaminated and spiked peanut samples by using a commercial AFB 1 ELISA kit as the reference, and well-matching results were obtained. Graphical abstract Schematic presentation of a photoelectrochemical immunoassay for AFB 1 . It is based on the use of Ce-doped Bi 2 MoO 6 nanosheets and of liposome-coated mesoporous silica nanoparticles loaded with L-cysteine.

  15. Novel photoluminescence enzyme immunoassay based on supramolecular host-guest recognition using L-arginine/6-aza-2-thiothymine-stabilized gold nanocluster.

    Science.gov (United States)

    Wang, Youmei; Lu, Minghua; Tang, Dianping

    2018-06-30

    A new photoluminescence (PL) enzyme immunoassay was designed for sensitive detection of aflatoxin B 1 (AFB 1 ) via an innovative enzyme substrate, 6-aza-2-thiothymine-stabilized gold nanocluster (AAT-AuNC) with L-arginine. The enzyme substrate with strong PL intensity was formed through supramolecular host-guest assembly between guanidine group of L-arginine and AAT capped on the surface of AuNC. Upon arginase introduction, the captured L-arginine was hydrolyzed into ornithine and urea, thus resulting in the decreasing PL intensity. Based on this principle, a novel competitive-type immunoreaction was first carried out on AFB 1 -bovine serum albumin (AFB 1 -BSA) conjugate-coated microplate, using arginase-labeled anti-AFB 1 antibody as the competitor. Under the optimum conditions, the PL intensity increased with the increment of target AFB 1 , and allowed the detection of the analyte at concentrations as low as 3.2 pg mL -1 (ppt). Moreover, L-arginine-AAT-AuNC-based PL enzyme immunoassay afforded good reproducibility and acceptable specificity. In addition, the accuracy of this methodology, referring to commercial AFB 1 ELISA kit, was evaluated to analyze naturally contaminated or spiked peanut samples, giving well-matched results between two methods, thus representing a useful scheme for practical application in quantitative monitoring of mycotoxins in foodstuff. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Microsoft Technology as an Optimization Tool in Promoting Security and Functionality of the Educational System

    Directory of Open Access Journals (Sweden)

    Jelena Jardas Antonic

    2008-10-01

    Full Text Available Abstract - In the cooperation with the City of Rijeka, the project of analysis of the functional and security situation of information infrastructure has been initiated in 24 schools in the authority of the city. Having completed the multicriteria analysis of the collected data, we have built a model of implementing Microsoft service technologies. The implementation should satisfy the elementary security principles that are required by the security standards today, maximizing functionality of infrastructure and minimizing network administration tasks. Server technology that has been used in this solution is Microsoft Widows 2003 Server R2 and Internet Security and Acceleration Server 2006, as well as the GFI WebMonitor and antivirus.

  17. Articulations on form properties and action-function couplings of maker technologies in children’s education

    DEFF Research Database (Denmark)

    Christensen, Kasper Skov; Iversen, Ole Sejer

    2016-01-01

    In this paper, we present a framework to expand the design language used to articulate form properties and types of feedback that happen between children’s actions and the intended functionality of maker technologies. Based on field observations in Danish schools we analyze children’s (aged 11......-14 years old) interactions with three maker technologies used to work through design processes in school maker settings. Our findings are beneficial on three factors for designers, researchers and teachers involved in work within maker contexts. (1) reflections on form properties of maker technologies, (2....... Researchers can use the expanded design language to analyze maker technologies in the context of school maker settings. Finally, teachers can make better decisions on how and when to use different maker technologies when school children work through design processes....

  18. Integrating proteomic and functional genomic technologies in discovery-driven translational breast cancer research

    DEFF Research Database (Denmark)

    Celis, Julio E; Gromov, Pavel; Gromova, Irina

    2003-01-01

    The application of state-of-the-art proteomics and functional genomics technologies to the study of cancer is rapidly shifting toward the analysis of clinically relevant samples derived from patients, as the ultimate aim of translational research is to bring basic discoveries closer to the bedside...

  19. Immunoassays for riboflavin and flavin mononucleotide using antibodies specific to d-ribitol and d-ribitol-5-phosphate.

    Science.gov (United States)

    Ravi, G; Venkatesh, Yeldur P

    2017-06-01

    Riboflavin (vitamin B 2 ), a water-soluble vitamin, plays a key role in maintaining human health. Though, numerous methods have been reported for the determination of total riboflavin (TRF) content in foods and biological samples, very few methods are reported for quantifying riboflavin and its coenzymes [flavin mononucleotide (FMN); flavin adenine dinucleotide (FAD)] individually. Recently, we have demonstrated that antibodies specific to d-ribitol and d-ribitol-5-phosphate also recognize riboflavin and FMN, respectively, and not vice-versa. In this study, we have evaluated these two antibodies for the analysis of riboflavin and FMN by indirect competitive ELISA (icELISA) in selected foods and pharmaceuticals. Under the optimal assay conditions, 50% inhibition concentration (IC 50 ) and limit of detection (LOD, IC 10 ) were 3.41ng/mL and 0.02ng/mL for riboflavin, and 7.84ng/mL and 0.24ng/mL for FMN, respectively, with detectable concentration range between 0.1 and 100ng of analytes and riboflavin and FMN) from the same food samples showed variation in their values compared to TRF, and were in good agreement with values obtained from HPLC and AOAC methods. Further, spiking and recovery analysis of food samples and pharmaceuticals showed no significant matrix effects. The immunoassays were validated in terms of accuracy and precision using inter- and intra-assays. The immunoassays developed in this study are sensitive and appears feasible for screening a large number of samples in the quantification of riboflavin and FMN in various biological samples, pharmaceuticals and natural/processed foods. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A new strategy for label-free electrochemical immunoassay based on “gate-effect” of β-cyclodextrin modified electrode

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Huan [College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004 (China); Li, Jianping, E-mail: likianping@263.net [College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004 (China); Zhang, Yun; Pan, Hongcheng [College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004 (China); Xu, Guobao, E-mail: guobaoxu@ciac.ac.cn [College of Chemistry and Bioengineering, Guilin University of Technology, Guilin 541004 (China); State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)

    2016-07-05

    A novel label-free electrochemical immunoassay was developed for prostate-specific antigen (PSA) detection via using β-cyclodextrin (β-CD) assembled layer created gates for the electron transfer of probe. To construct the sensor, a gold electrode was self-assembled with monoclonal anti-PSA antibody labeled 6-mercapto-β-cyclodextrin. Interspaces among β-CD molecules in the layer were automatically formed on gold electrode, which act as the channel of the electron transfer of [Fe(CN){sub 6}]{sup 3−/4−} probe. When PSA bind with anti-PSA, it can block these channels on the electrode surface due to their steric hindrance effect, resulting in the decrease in redox current of the probe. Through such a gate-controlled effect, ultra trace amount of PSA may make the currents change greatly after the immunoreaction, which enhanced the signal-to-noise ratio to achieve the amplification effect. By evaluating the logarithm of PSA concentrations, the immunosensor had a good linear response to the current changes with a detection limit of 0.3 pg/mL (S/N = 3) when PSA concentration ranged from 1.0 pg/mL to 1.0 ng/mL. The label-free immunosensor exhibited satisfactory performances in sensitivity, repeatability as well as specificity. - Highlights: • A label-free PSA immunoassay was developed based on “gate-effect” amplification. • Interspaces among β-CD assembled for [Fe(CN){sub 6}]{sup 3−/4−} electron transfer were controlled by the immunoreaction. • Higher sensitivity was achieved with time and cost saving principle.

  1. Detection of Aspergillus fumigatus mycotoxins: immunogen synthesis and immunoassay development.

    Science.gov (United States)

    Fox, M; Gray, G; Kavanagh, K; Lewis, C; Doyle, S

    2004-02-01

    Immunological detection of secreted low molecular weight toxins represents a potentially novel means of diagnosing infection by the fungus Aspergillus fumigatus. Two such metabolites, gliotoxin and helvolic acid, were selected and conjugated to thyroglobulin for antisera generation in rabbits. Gliotoxin was initially activated using N-[p-maleimidophenyl] isocyanate (PMPI) and subsequently conjugated to S-acetyl thioglycolic acid N-hydroxysuccinimide-activated thyroglobulin, whereas helvolic acid was activated with N-(3-Dimethylaminopropyl)-N'-ethylcarbodiimide (EDC) in the presence of thyroglobulin prior to immunisation. To facilitate subsequent antisera evaluation, both toxins were similarly conjugated to bovine serum albumin (BSA). Matrix-Assisted Laser Desorption Ionisation-Time Of Flight (MALDI-TOF) mass spectrometry and SDS-PAGE analysis confirmed covalent attachment of toxins to BSA in the ratios of 15 and 2.4 mol per mol BSA for gliotoxin and helvolic acid, respectively. Resultant high titer antisera were capable of detecting both BSA-conjugated toxins (inhibitory concentration (IC)(50): 4-5 microg/ml). Free toxins were also detectable by competitive immunoassay, whereby 10 microg/ml free gliotoxin (30 microM) and helvolic acid (17 microM), respectively, inhibited antibody binding to cognate toxin-BSA previously immobilised on microwells. This work confirms that sensitive and specific antisera can be raised against fungal toxins and may have an application in diagnosing fungal infection.

  2. Application of a Newly Developed High-Sensitivity HBsAg Chemiluminescent Enzyme Immunoassay for Hepatitis B Patients with HBsAg Seroclearance

    OpenAIRE

    Shinkai, Noboru; Matsuura, Kentaro; Sugauchi, Fuminaka; Watanabe, Tsunamasa; Murakami, Shuko; Iio, Etsuko; Ogawa, Shintaro; Nojiri, Shunsuke; Joh, Takashi; Tanaka, Yasuhito

    2013-01-01

    We modified and automated a highly sensitive chemiluminescent enzyme immunoassay (CLEIA) for surface antigen (HBsAg) detection using a combination of monoclonal antibodies, each for a specific epitope of HBsAg, and by improving an earlier conjugation technique. Of 471 hepatitis B virus (HBV) carriers seen in our hospital between 2009 and 2012, 26 were HBsAg seronegative as determined by the Abbott Architect assay. The Lumipulse HBsAg-HQ assay was used to recheck those 26 patients who demonstr...

  3. INNOVATIVE TECHNOLOGICAL SOLUTIONS IN CREATING FUNCTIONAL PRODUCTS POWER

    Directory of Open Access Journals (Sweden)

    I. V. Sergienko

    2015-01-01

    Full Text Available The article deals with a problem of functional products creation for consumers feeling need in proteins, irreplaceable amino acids, vitamins, mineral substances, food fibers, polynonsaturated fat acids. One of the possible ways to improve human nutrition is using non-traditional cultures for bread making technology containing significant amounts of fibrous substances, easily digestible protein, vitamins, unsaturated fatty acids and minerals. Taking into account the Nutrition Science requirements an expediency of the most full functional ingredients complex entering into bakery products prescription structure is proved. Replacement of the first grade wheat flour by the offered prescription composition allows to slow down a bread aging, to increase periods of products storage and to improve their physical and chemical indicators on the specific volume and porosity. The bakery products "Svyatogor" at the use of 100 g of a product allow to cover daily need in protein for 38,9%, in carbohydrates – for 3,4%, fat – for 9,2%. The power value of "Svyatogor" is 897 kJ, in control 959. Biological value, % 82,7 against 53,1 in control. Thanks to it the digestibility of bread protein (in vitro method of “Svyatogor” is higher. Thanks to unique properties of the compounding components “Svyatogor” gets functional properties by full-fledged protein increasing and its best comprehensibility (in vitro, advanced structure according to the content of vitamins, mineral substances, their balanced structure and can be recommended for mass consumption and prevention of osteoporosis, atherosclerosis, anemia, for children food, pregnant women and the feeding women.

  4. Functional materials for information and energy technology: Insights by photoelectron spectroscopy

    International Nuclear Information System (INIS)

    Müller, Martina; Nemšák, Slavomír; Plucinski, Lukasz; Schneider, Claus M.

    2016-01-01

    Highlights: • Photoemission spectro/microscopy studies of functional material systems. • Hard X-ray photoemission spectroscopy from magnetic semiconductors and insulators. • Information depth studies in hard X-ray photoemission microscopy. • Soft X-ray standing wave ambient pressure photoemission spectroscopy from liquid films. - Abstract: The evolution of both information and energy technology is intimately connected to complex condensed matter systems, the properties of which are determined by electronic and chemical interactions and processes on a broad range of length and time scales. Dedicated photoelectron spectroscopy and spectromicroscopy experiments can provide important insights into fundamental phenomena and applied functionalities. We discuss some recent methodological developments with application to relevant questions in spintronics, and towards operando studies of resistive switching and electrochemical processes.

  5. Functionally graded scaffolds for the engineering of interface tissues using hybrid twin screw extrusion/electrospinning technology

    Science.gov (United States)

    Erisken, Cevat

    Tissue engineering is the application of the principles of engineering and life sciences for the development of biological alternatives for improvement or regeneration of native tissues. Native tissues are complex structures with functions and properties changing spatially and temporally, and engineering of such structures requires functionally graded scaffolds with composition and properties changing systematically along various directions. Utilization of a new hybrid technology integrating the controlled feeding, compounding, dispersion, deaeration, and pressurization capabilities of extrusion process with electrospinning allows incorporation of liquids and solid particles/nanoparticles into polymeric fibers/nanofibers for fabrication of functionally graded non-woven meshes to be used as scaffolds in engineering of tissues. The capabilities of the hybrid technology were demonstrated with a series of scaffold fabrication and cell culturing studies along with characterization of biomechanical properties. In the first study, the hybrid technology was employed to generate concentration gradations of beta-tricalcium phosphate (beta-TCP) nanoparticles in a polycaprolactone (PCL) binder, between two surfaces of nanofibrous scaffolds. These scaffolds were seeded with pre-osteoblastic cell line (MC3T3-E1) to attempt to engineer cartilage-bone interface, and after four weeks, the tissue constructs revealed formation of continuous gradations in extracellular matrix akin to cartilage-bone interface in terms of distributions of mineral concentrations and biomechanical properties. In a second demonstration of the hybrid technology, graded differentiation of stem cells was attempted by using insulin, a known stimulator of chondrogenic differentiation, and beta-glycerol phosphate (beta-GP), for mineralization. Concentrations of insulin and beta-GP in PCL were controlled to monotonically increase and decrease, respectively, along the length of scaffolds, which were then seeded

  6. Effects of saliva collection using cotton swab on cortisol enzyme immunoassay.

    Science.gov (United States)

    Kozaki, Tomoaki; Hashiguchi, Nobuko; Kaji, Yumi; Yasukouchi, Akira; Tochihara, Yutaka

    2009-12-01

    Cotton swabs are among the most commonly used devices for collecting saliva, but various studies have reported that their use impacts the results of salivary cortisol assays. These studies, however, estimated this impact by comparing the average of the concentration and/or scatter plots. In the present study, we estimated the impact of cotton swabs on the results of salivary cortisol enzyme immunoassay (EIA) by Bland-Altman plot. Eight healthy males (aged 20-23 years) provided four saliva samples on different days to yield a total of 32 samples. Saliva samples were collected directly in plastic tubes using plastic straws and then pipetted onto cotton swabs (cotton saliva collection) and into clear sterile tubes (passive saliva collection). There was a lower correlation between cotton and passive saliva collection. Individually, four subjects showed a negative correlation between passive and cotton saliva collection. A Bland-Altman plot indicated that cotton swabs causes a proportional bias on the EIA assay result. Our findings indicate a considerable effect of using cotton swabs for saliva collection, and subject-specific variability in the impact. A Bland-Altman plot further suggests possible reasons for this effect.

  7. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China); Hao, Fen [DaAn Gene Co. Ltd. of Sun Yat-sen University, 19 Xiangshan Road, Guangzhou 510515 (China); Wu, Ying-Song, E-mail: wg@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China)

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (H{sub T}) and the control line (H{sub C}); the H{sub T}/H{sub C} ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0–1000 IU mL{sup −1}) for AFP with a low limit of detection (0.1 IU mL{sup −1}) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. - Highlights: • Europium (III) chelate microparticles was used as a label for LIFA. • Quantitative detection by using H{sub T}/H{sub C} ratio was achieved. • LIFA for simple and rapid AFP detection in human serum. • The sensitivity and linearity was more excellent compared with QD-based ICTS. • This method could be developed for rapid point-of-care screening.

  8. Optimization and validation of CEDIA drugs of abuse immunoassay tests in serum on Hitachi 912.

    Science.gov (United States)

    Kirschbaum, Katrin M; Musshoff, Frank; Schmithausen, Ricarda; Stockhausen, Sarah; Madea, Burkhard

    2011-10-10

    Due to sensitive limits of detection of chromatographic methods and low limit values regarding the screening of drugs under the terms of impairment in safe driving (§ 24a StVG, Street Traffic Law in Germany), preliminary immunoassay (IA) tests should be able to detect also low concentrations of legal and illegal drugs in serum in forensic cases. False-negatives should be avoided, the rate of false-positive samples should be low due to cost and time. An optimization of IA cutoff values and a validation of the assay is required for each laboratory. In a retrospective study results for serum samples containing amphetamine, methylenedioxy derivatives, cannabinoids, benzodiazepines, cocaine (metabolites), methadone and opiates obtained with CEDIA drugs of abuse reagents on a Hitachi 912 autoanalyzer were compared with quantitative results of chromatographic methods (gas or liquid chromatography coupled with mass spectrometry (GC/MS or LC/MS)). Firstly sensitivity, specificity, positive and negative predictive values and overall misclassification rates were evaluated by contingency tables and compared to ROC-analyses and Youden-Indices. Secondly ideal cutoffs were statistically calculated on the basis of sensitivity and specificity as decisive statistical criteria with focus on a high sensitivity (low rates of false-negatives), i.e. using the Youden-Index. Immunoassay (IA) and confirmatory results were available for 3014 blood samples. Sensitivity was 90% or more for nearly all analytes: amphetamines (IA cutoff 9.5 ng/ml), methylenedioxy derivatives (IA cutoff 5.5 ng/ml), cannabinoids (IA cutoff 14.5 ng/ml), benzodiazepines (IA cutoff >0 ng/ml). Test of opiates showed a sensitivity of 86% for a IA cutoff value of >0 ng/ml. Values for specificity ranged between 33% (methadone, IA cutoff 10 ng/ml) and 90% (cocaine, IA cutoff 20 ng/ml). Lower cutoff values as recommended by ROC analyses were chosen for most tests to decrease the rate of false-negatives. Analyses enabled

  9. Detection of Pesticides and Pesticide Metabolites Using the Cross Reactivity of Enzyme Immunoassays

    Science.gov (United States)

    Thurman, E.M.; Aga, D.S.

    2001-01-01

    Enzyme immunoassay is an important environmental analysis method that may be used to identify many pesticide analytes in water samples. Because of similarities in chemical structure between various members of a pesticide class, there often may be an unwanted response that is characterized by a percentage of cross reactivity. Also, there may be cross reactivity caused by degradation products of the target analyte that may be present in the sample. In this paper, the concept of cross reactivity caused by degradation products or by nontarget analytes is explored as a tool for identification of metabolites or structurally similar compounds not previously known to be present in water samples. Two examples are examined in this paper from various water quality studies. They are alachlor and its metabolite, alachlor ethane sulfonic acid, and atrazine and its class members, prometryn and propazine. A method for using cross reactivity for the detection of these compounds is explained in this paper.

  10. The significance for epidemiological studies anti-measles antibody detection examined by enzyme immunoassay (EIA) and plaque reduction neutralization test (PRNT).

    Science.gov (United States)

    Siennicka, Joanna; Częścik, Agnieszka; Trzcińska, Agnieszka

    2014-01-01

    The paper discusses the role of anti-measles antibodies for protection and significance for epidemiological studies determination of antibodies by different serological methods. The comparison of anti-measles virus antibodies levels measured by enzyme immunoassay (EIA) and Plaque Reduction Neutralization Test (PRNT) was described. It was found that the 200 mIU/ml of anti-measles activity measured by PRNT (level protection against symp- tomatic disease) is equivalent of 636 mIU/ml measured by EIA (Enzygnost®Anti-Measles Virus/IgG, Simens).

  11. Enzyme immunoassay for rabies antibody in hybridoma culture fluids and its application to differentiation of street and laboratory strains of rabies virus.

    OpenAIRE

    Smith, J S; Sumner, J W; Roumillat, L F

    1984-01-01

    A rapid and sensitive enzyme immunoassay is described for detecting rabies antibody in hybridoma culture fluids. Glass fiber filter disks were used to immobilize gamma-irradiated mouse neuroblastoma cells infected with street or laboratory strains of rabies virus. Bound rabies-specific antibody was detected by reaction with horseradish peroxidase-labeled goat anti-mouse immunoglobulin G. The assay was performed in a 96-well filtration device developed by Cleveland et al. (J. Clin. Microbiol. ...

  12. Sensitive chemiluminescence immunoassay for staphylococcal enterotoxin C1 based on the use of dye-encapsulated mesoporous silica nanoparticles

    International Nuclear Information System (INIS)

    Tao, Liang; Zhang, Chunmei; Sun, Yuanjie; Jin, Boquan; Yang, Kun; Li, Xiaohua; Zhang, Zhujun; Zhang, Jinpeng; Yan, Kuocheng

    2016-01-01

    A chemiluminescent immunoassay for the staphylococcal enterotoxin C1 (SEC1) based on the use of dye-encapsulated mesoporous silica nanoparticles (m-SiNPs) as a label is described. The dyes are retained in the m-SiNPs via strong hydrophobic interactions. The assay comprises the following steps: (a) Microplates coated with antibody against SEC1 are filled with sample upon which the SEC antigen will be bound to the surface; (b) following a washing step, secondary antibody linked to m-SiNPs (that were covalently labeled with rhodamine 6G and fluorescein) were added to form the sandwich complex; (c) after another washing step, bis(2,4,6-trichlorophenyl) oxalate, H_2O_2 and imidazole are added to generate chemiluminescence whose intensity is proportional to the number of m-SiNPs and thus to the number of antigen (SEC) molecules. It is found that the use of functionalized m-SiNPs strongly amplifies the signal. Enterotoxin SEC1 can be detected by this method in the 0.025 to 2 ng⋅mL"-"1 concentration range, the detection limit is 19 pg⋅mL"-"1 (at 3σ), and the relative standard deviation (for 11 parallel measurements at a 1 ng⋅mL"-"1 level) is 4.6 %. The use of an automated chemiluminescence analyzer further improves detection. (author)

  13. A sandwich-type electrochemical immunoassay for ultrasensitive detection of non-small cell lung cancer biomarker CYFRA21-1.

    Science.gov (United States)

    Zeng, Yan; Bao, Jing; Zhao, Yanan; Huo, Danqun; Chen, Mei; Qi, Yanli; Yang, Mei; Fa, Huanbao; Hou, Changjun

    2018-04-01

    Many studies confirm that the aberrant expression of Cytokeratin 19 fragment 21-1 (CYFRA21-1) is highly correlated with non-small cell lung cancer (NSCLC), especially for squamous cell carcinoma. Herein, we report a sandwich-type electrochemical immunosensor based on signal amplification strategy of multiple nanocomposites to test CYFRA21-1 selectively and sensitively. The proposed immunosensor fabricated by three-dimensional graphene (3D-G), chitosan (CS) and glutaraldehyde (GA) composite on the glass carbon electrode (GCE) with a large surface area is prepared to immobilize primary antibodies (Ab 1 ) and provide excellent conductivity. To further amplify the electrochemical signal, the trace tag on the foundation of gold nanoparticles (AuNPs) is coated with amino-functionalized carbon nanotube (MWCNT-NH 2 ) nanocomposite through thionine linking, which provides more amino groups to capture more horseradish peroxidase-labeled antibodies (HPR-Ab 2 ) and enhances the conductivity. Under optimal conditions, the developed immunosensor exhibits excellent analytical performance for the determination of CYFRA21-1 with a wide linear range from 0.1 to 150ng·mL -1 and a low detection limit (LOD) of 43pg·mL -1 . Furthermore, satisfactory results are obtained for the determination of CYFRA21-1 in real clinical serum samples, indicating the potential of the immunoassay to be applied in clinical analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Minimally Processed Functional Foods: Technological and Operational Pathways.

    Science.gov (United States)

    Rodgers, Svetlana

    2016-10-01

    This paper offers a concise review of technical and operational concepts underpinning commercialization of minimally processed functional foods (FFs), foods with fresh-like qualities commanding premium prices. The growing number of permitted nutritional content/health claims, many of which relate to well-being, coupled with emerging extraction and food processing technologies offers new exciting opportunities for small and medium size enterprises (SMEs) specializing in fresh produce to play an active role in the health market. Supporting SMEs, governments could benefit from savings in healthcare costs and value creation in the economy. Consumers could benefit from novel FF formats such as refrigerated RTE (ready-to-eat) meals, a variety of fresh-like meat-, fish-, and egg-based products, fresh-cut fruits and vegetables, cereal-based fermented foods and beverages. To preserve these valuable commodities, mild biological (enzymatic treatment, fermentation and, bio-preservation) and engineering solutions are needed. The latter include nonthermal techniques such as high-pressure treatment, cook-chill, sous-vide, mirco-encapsulation, vacuum impregnation and others. "De-constructive" culinary techniques such as 3D food printing and molecular gastronomy as well as developments in nutrigenomics and digital technologies facilitate novel product formats, personalization and access to niche markets. In the operational sense, moving from nourishment to health improvement demands a shift from defensive market-oriented to offensive market-developing strategies including collaborative networks with research organizations. © 2016 Institute of Food Technologists®.

  15. [Progress in isokinetic technology in testing and training for assessment of muscle function].

    Science.gov (United States)

    Huang, Ting-Ting; Fan, Li-Hua; Gao, Dong; Xia, Qing; Zhang, Min

    2013-02-01

    Isokinetic technology in testing and training is the most advanced practical technique in the evaluation of muscle function. This method is a continuous dynamic test in the full range of the joint motion which has strong pertinence at the aspect of assessing muscle strength, and is an objective and quantitative method for reflecting each point's muscle strength in the range of the joint motion. This article reviews the key concepts, brief history of development and influencing factors of isokinetic technology in testing and training, introduces the progress in the field of rehabilitation medicine and sport science, etc., and discusses the future exploration in forensic science.

  16. THE SYNTHESIS AND ANALYSIS INFORMATION TECHNOLOGY OF INTERACTIVE REGULATIONS FUNCTIONAL MODELS

    Directory of Open Access Journals (Sweden)

    Владимир Александрович ТИМОФЕЕВ

    2016-02-01

    Full Text Available A person has no ability to capture entirely and to estimate correctly the logical coherence and consistency of Regulations in the Text Form. It leads to mistakes in a work of an Enterprise Staff and to the impossibility of mastering of the Regulations with considerable volume. Presented Information Technology allows the Regulations Executor to receive on-line proper information of the Optimum Actions in any possible Situation, which can arise in the course of the work. Leading Experts of any Enterprise may create the full-fledged Expert System by themselves with the help of Specialized Software. Such a System will contain the knowledge in the Functional Model of Regulations (the Optimum Business Process. Stages of realization of the represented Information Technology and the peculiarities of on-line data displaying for the Regulations Executor are illustrated by the Pharmacy Customer Service Regulations.

  17. Evaluation of the microparticle enzyme immunoassay Abbott IMx Select Chlamydia and the importance of urethral site sampling to detect Chlamydia trachomatis in women.

    OpenAIRE

    Brokenshire, M K; Say, P J; van Vonno, A H; Wong, C

    1997-01-01

    OBJECTIVE: To evaluate the commercial microparticle enzyme immunoassay (MEIA), Abbott IMx Select Chlamydia, for the detection of Chlamydia trachomatis in women and to compare its performance with endocervical cell culture. Also, to determine whether sampling the urethral site is an important part of chlamydial diagnosis in women. SETTING: The Auckland, Manukau, and Waitakere Sexual Health Clinics, Auckland, New Zealand and the Department of Clinical Microbiology, Auckland Hospital, Auckland, ...

  18. An Anti-proteome Nanobody Library Approach Yields a Specific Immunoassay for Trypanosoma congolense Diagnosis Targeting Glycosomal Aldolase.

    Directory of Open Access Journals (Sweden)

    Steven Odongo

    2016-02-01

    Full Text Available Infectious diseases pose a severe worldwide threat to human and livestock health. While early diagnosis could enable prompt preventive interventions, the majority of diseases are found in rural settings where basic laboratory facilities are scarce. Under such field conditions, point-of-care immunoassays provide an appropriate solution for rapid and reliable diagnosis. The limiting steps in the development of the assay are the identification of a suitable target antigen and the selection of appropriate high affinity capture and detection antibodies. To meet these challenges, we describe the development of a Nanobody (Nb-based antigen detection assay generated from a Nb library directed against the soluble proteome of an infectious agent. In this study, Trypanosoma congolense was chosen as a model system.An alpaca was vaccinated with whole-parasite soluble proteome to generate a Nb library from which the most potent T. congolense specific Nb sandwich immunoassay (Nb474H-Nb474B was selected. First, the Nb474-homologous sandwich ELISA (Nb474-ELISA was shown to detect experimental infections with high Positive Predictive Value (98%, Sensitivity (87% and Specificity (94%. Second, it was demonstrated under experimental conditions that the assay serves as test-of-cure after Berenil treatment. Finally, this assay allowed target antigen identification. The latter was independently purified through immuno-capturing from (i T. congolense soluble proteome, (ii T. congolense secretome preparation and (iii sera of T. congolense infected mice. Subsequent mass spectrometry analysis identified the target as T. congolense glycosomal aldolase.The results show that glycosomal aldolase is a candidate biomarker for active T. congolense infections. In addition, and by proof-of-principle, the data demonstrate that the Nb strategy devised here offers a unique approach to both diagnostic development and target discovery that could be widely applied to other infectious

  19. High-sensitivity chemiluminescence immunoassays for detection of growth hormone doping in sports.

    Science.gov (United States)

    Bidlingmaier, Martin; Suhr, Jennifer; Ernst, Andrea; Wu, Zida; Keller, Alexandra; Strasburger, Christian J; Bergmann, Andreas

    2009-03-01

    Recombinant human growth hormone (rhGH) is abused in sports, but adequate routine doping tests are lacking. Analysis of serum hGH isoform composition has been shown to be effective in detecting rhGH doping. We developed and validated selective immunoassays for isoform analysis with potential utility for screening and confirmation in doping tests. Monoclonal antibodies with preference for pituitary hGH (phGH) or rhGH were used to establish 2 pairs of sandwich-type chemiluminescence assays with differential recognition of rhGH (recA and recB) and phGH (pitA and pitB). We analyzed specimens from volunteers before and after administration of rhGH and calculated ratios between the respective rec- and pit-assay results. Functional sensitivities were <0.05 microg/L, with intra- and interassay imprecision < or =8.4% and < or =13.7%, respectively. In 2 independent cohorts of healthy subjects, rec/pit ratios (median range) were 0.84 (0.09-1.32)/0.81 (0.27-1.21) (recA/pitA) and 0.68 (0.08-1.20)/0.80 (0.25-1.36) (recB/pitB), with no sex difference. In 20 recreational athletes, ratios (median SD) increased after a single injection of rhGH, reaching 350% (73%) (recA/pitA) and 400% (93%) (recB/pitB) of baseline ratios. At a moderate dose (0.033 mg/kg), mean recA/pitA and recB/pitB ratios remained significantly increased for 18 h (men) and 26 h (women). After high-dose rhGH (0.083 mg/kg), mean rec/pit ratios remained increased for 32 h (recA/pitA) and 34 h (recB/pitB) in men and were still increased after 36 h in women. Using sensitive chemiluminescence assays with preferential recognition of phGH or rhGH, detection of a single injection of rhGH was possible for up to 36 h.

  20. Double Antibody Method for Immunoassay of Insulin. Its Application in Population Studies

    Energy Technology Data Exchange (ETDEWEB)

    Welborn, T. A.; Stenhouse, N. S.; Curnow, D. H.; Johnstone, Clare J. [Department of Medicine, Raine Foundation Medical Statistics Unit and Department of Pathology, University of Western Australia, Perth (Australia)

    1970-02-15

    The performance of a double-antibody Immunoassay technique over a period of two years is described, during which 3300 samples from population studies were analysed for insulin concentration. The method requires safeguards to ensure that complete separation of ''free'' from ''antibody-bound'' hormone is achieved, thus labelled gamma-globulin is used in the precise preliminary standardization of precipitating antibody. The dose-response curves for crystalline insulin standards over a range of concentration 0.2 to 16,0 ng (5 to 400 micro-International-Units)/ml are consistently nonlinear, but a close fit is obtained by a cubic function obtained empirically from multiple regression analysis, which also corrects satisfactorily for ''within-assay drift'' when large numbers of samples are involved. The coefficient of variation for pooled serum standards repetitively assayed ranged from 10 to 14%. Sources of ''between-assay variability'' of the serum standards include variable integrity of the labelled insulin and the slope of the standard curve. For quality control material, the need for standards of serum as well as crystalline insulin is stressed, Serum-insulin was measured in 3300 adults of the population of Busselton, approximately 1 h after a 50 g oral glucose load. The concentrations were distributed log-normally. Females had significantly higher 'one-hour' serum-insulin levels than males, and both sexes showed a moderate rise of values with age. Multiple regression analyses revealed that the major determinant of serum-insulin was the blood-sugar level, the independent relationship being such that at ''one-hour'' blood-sugar levels exceeding 160 - 180 mg/100 ml, a decline of insulin values occurred. Body-weight had a strong positive association, and height a negative relationship, with the ''one-hour'' serum-insulin. Males with coronary heart disease and hypertension showed elevated insulin levels under 60 years of age, whereas ''ideal'' males (with obesity

  1. Biotin IgM Antibodies in Human Blood: A Previously Unknown Factor Eliciting False Results in Biotinylation-Based Immunoassays

    Science.gov (United States)

    Chen, Tingting; Hedman, Lea; Mattila, Petri S.; Jartti, Laura; Jartti, Tuomas; Ruuskanen, Olli; Söderlund-Venermo, Maria; Hedman, Klaus

    2012-01-01

    Biotin is an essential vitamin that binds streptavidin or avidin with high affinity and specificity. As biotin is a small molecule that can be linked to proteins without affecting their biological activity, biotinylation is applied widely in biochemical assays. In our laboratory, IgM enzyme immuno assays (EIAs) of µ-capture format have been set up against many viruses, using as antigen biotinylated virus like particles (VLPs) detected by horseradish peroxidase-conjugated streptavidin. We recently encountered one serum sample reacting with the biotinylated VLP but not with the unbiotinylated one, suggesting in human sera the occurrence of biotin-reactive antibodies. In the present study, we search the general population (612 serum samples from adults and 678 from children) for IgM antibodies reactive with biotin and develop an indirect EIA for quantification of their levels and assessment of their seroprevalence. These IgM antibodies were present in 3% adults regardless of age, but were rarely found in children. The adverse effects of the biotin IgM on biotinylation-based immunoassays were assessed, including four inhouse and one commercial virus IgM EIAs, showing that biotin IgM do cause false positivities. The biotin can not bind IgM and streptavidin or avidin simultaneously, suggesting that these biotin-interactive compounds compete for the common binding site. In competitive inhibition assays, the affinities of biotin IgM antibodies ranged from 2.1×10−3 to 1.7×10−4 mol/L. This is the first report on biotin antibodies found in humans, providing new information on biotinylation-based immunoassays as well as new insights into the biomedical effects of vitamins. PMID:22879954

  2. Quantum dots-based lateral flow immunoassay combined with image analysis for semiquantitative detection of IgE antibody to mite

    Directory of Open Access Journals (Sweden)

    Zhao Y

    2017-07-01

    Full Text Available Yan Zhao,1,* Qiang Zhang,2,* Qingfeng Meng,3 Fenglian Wu,4 Lihua Zhang,1 Yao Tang,1 Yuanyuan Guan,1 Lixin An1 1Department of Allergy, The First Affiliated Hospital, Harbin Medical University, Harbin, 2Department of Otorhinolaryngology Head and Neck Surgery, The Affiliated Yantai Yuhuangding Hospital, Qingdao University, Yantai, 3Department of Ophthalmology, The First Affiliated Hospital, Harbin Medical University, Harbin, 4Department of Burn and Plastic Surgery, The First Affiliated Hospital of Qinhuangdao, Qinhuangdao, People’s Republic of China *These authors contributed equally to this work Abstract: Semiquantitative and rapid detection of specific IgE (sIgE with well clinical relevance to house dust mite (HDM are promising for prevalence rhinitis and asthma patients due to the increasing air pollution. However, the conventional IgE measurement systems are time-consuming, complicated and require special instruments. Herein, we overcome the above limitations of sIgE to HDM detection system by developing a quantum dot nanobeads-based lateral flow immunoassay and an image analysis procedure. The proposed detection system could semiquantitatively measure the IgE in a linear range of 0.2–10 U/mL. Moreover, there is a well correlation between the developed detection system and the clinical symptoms by a comparison study using 56 positive patients’ sera and 40 healthy control sera. The proposed detection system is simple, robust and easy-to-use and promising for in home test. Keywords: lateral flow immunoassay, quantum dots, house dust mite, IgE 

  3. Comparison among performances of a ligase chain reaction-based assay and two enzyme immunoassays in detecting Chlamydia trachomatis in urine specimens from men with nongonococcal urethritis.

    Science.gov (United States)

    Deguchi, T; Yasuda, M; Uno, M; Tada, K; Iwata, H; Komeda, H; Maeda, S; Latila, V; Saito, I; Kawada, Y

    1996-01-01

    We evaluated the performances of a ligase chain reaction (LCR)-based assay and two enzyme immunoassays (Chlamydiazyme and IDEIA) in the detection of Chlamydia trachomatis in urine specimens. We compared the results of testing urine specimens by these assays with those of urethral swab culture by examining samples from 131 men with nongonococcal urethritis. Discrepant results were analyzed by testing urethral swab specimens for C. trachomatis by a PCR-based assay. After the resolution of discrepant results, the sensitivity of urethral swab culture was 85.3%, whereas those of the LCR assay, Chlamydiazyme, and IDEIA with urine specimens were 94.1, 82.4, and 94.1%, respectively. The LCR assay and IDEIA were more sensitive than was urethral swab culture. In addition, the LCR assay, with a sensitivity equal to that of IDEIA, was more specific. Overall, the LCR assay proved to be superior to the enzyme immunoassays in detecting C. trachomatis in urine specimens. Testing urine specimens by LCR assay should be a helpful alternative method for diagnosing C. trachomatis urethral infection in men with nongonococcal urethritis. PMID:8784574

  4. Homogeneous immunoassay for the cancer marker alpha-fetoprotein using single wavelength excitation fluorescence cross-correlation spectroscopy and CdSe/ZnS quantum dots and fluorescent dyes as labels

    International Nuclear Information System (INIS)

    Wang, Jinjie; Liu, Heng; Huang, Xiangyi; Ren, Jicun

    2016-01-01

    The article describes sensitive and selective homogeneous immunoassays for the liver cancer biomarker alpha-fetoprotein (AFP) in human serum by using single wavelength excitation fluorescence cross-correlation spectroscopy (SW-FCCS). Both competitive and sandwich immunoassay modes were applied, and AFP served as a model analyte. Fluorescent CdSe/ZnS quantum dots (with a 655 nm emission peak) and the fluorophore Alexa Fluor 488 (520 nm emission) were chosen to label the antibodies in the sandwich mode, and the antibody and the antigen in the competitive mode. Under optimized conditions, the sandwich assay has a linear dynamic range that covers the 20 pM to 5.0 nM concentration range. The competitive assay, in turn, extends from 180 pM to 15.0 nM. The respective detection limits are 20 pM and 180 pM. The method was successfully applied to directly determine AFP in (spiked) clinical samples, and results were in good agreement with data obtained via ELISAs. (author)

  5. Analytic validation and comparison of three commercial immunoassays for measurement of plasma atrial/A-type natriuretic peptide concentration in horses

    DEFF Research Database (Denmark)

    Trachsel, D S; Schwarzwald, C C; Grenacher, B

    2014-01-01

    Measurement of atrial/A-type natriuretic peptide (ANP) concentrations may be of use for assessment of cardiac disease, and reliable data on the analytic performance of available assays are needed. To assess the suitability for clinical use of commercially available ANP assays, intra-assay and inter......-Altman analyses. For all assays, precision was moderate but acceptable and dilution parallelism was good. All assays showed analytic performance similar to other immunoassays used in veterinary medicine. However, the results from the three assays were poorly comparable. Our study highlights the need...

  6. High-sensitivity detection of cardiac troponin I with UV LED excitation for use in point-of-care immunoassay

    DEFF Research Database (Denmark)

    Rodenko, Olga; Eriksson, Susann; Tidemand-Lichtenberg, Peter

    2017-01-01

    of an immunoassay analyzer employing an optimized LED excitation to measure on a standard troponin I and a novel research high-sensitivity troponin I assay. The limit of detection is improved by factor of 5 for standard troponin I and by factor of 3 for a research high-sensitivity troponin I assay, compared...... to the flash lamp excitation. The obtained limit of detection was 0.22 ng/L measured on plasma with the research highsensitivity troponin I assay and 1.9 ng/L measured on tris-saline-azide buffer containing bovine serum albumin with the standard troponin I assay. We discuss the optimization of time...

  7. Development of a highly sensitive and specific immunoassay for enrofloxacin based on heterologous coating haptens.

    Science.gov (United States)

    Wang, Zhanhui; Zhang, Huiyan; Ni, Hengjia; Zhang, Suxia; Shen, Jianzhong

    2014-04-11

    In the paper, an enzyme-linked immunosorbent immunoassay (ELISA) for detection of enrofloxacin was described using one new derivative of enrofloxacin as coating hapten, resulting in surprisingly high sensitivity and specificity. Incorporation of aminobutyric acid (AA) in the new derivative of enrofloxacin had decreased the IC50 of the ELISA for enrofloxacin from 1.3 μg L(-1) to as low as 0.07 μg L(-1). The assay showed neglect cross-reactivity for other fluoroquinolones but ofloxacin (8.23%), marbofloxacin (8.97%) and pefloxacin (7.29%). Analysis of enrofloxacin fortified chicken muscle showed average recoveries from 81 to 115%. The high sensitivity and specificity of the assay makes it a suitable screening method for the determination of low levels of enrofloxacin in chicken muscle without clean-up step. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Mapping of Epitopes Occurring in Bovine α(s1)-Casein Variants by Peptide Microarray Immunoassay.

    Science.gov (United States)

    Lisson, Maria; Erhardt, Georg

    2016-01-01

    Immunoglobulin E epitope mapping of milk proteins reveals important information about their immunologic properties. Genetic variants of αS1-casein, one of the major allergens in bovine milk, are until now not considered when discussing the allergenic potential. Here we describe the complete procedure to assess the allergenicity of αS1-casein variants B and C, which are frequent in most breeds, starting from milk with identification and purification of casein variants by isoelectric focusing (IEF) and anion-exchange chromatography, followed by in vitro gastrointestinal digestion of the casein variants, identification of the resulting peptides by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS), in silico analysis of the variant-specific peptides as allergenic epitopes, and determination of their IgE-binding properties by microarray immunoassay with cow's milk allergic human sera.

  9. Studies on the metabolism and toxicological detection of the amphetamine-like anorectic fenproporex in human urine by gas chromatography-mass spectrometry and fluorescence polarization immunoassay.

    Science.gov (United States)

    Kraemer, T; Theis, G A; Weber, A A; Maurer, H H

    2000-01-28

    Studies on the metabolism and the toxicological analysis of fenproporex (R,S-3-[(1-phenyl-2-propyl)-amino]-propionitrile, FP) using GC-MS and fluorescence polarization immunoassay are described. The metabolites were identified in urine samples of volunteers by GC-MS after cleavage of conjugates, extraction and acetylation. Besides unchanged FP, fourteen metabolites, including amphetamine, could be identified. Two partially overlapping metabolic pathways could be postulated: ring degradation by one- and two-fold aromatic hydroxylation followed by methylation and side chain degradation by N-dealkylation to amphetamine (AM). A minor pathway leads via beta-hydroxylation of AM to norephedrine. For GC-MS detection, the systematic toxicological analysis procedure including acid hydrolysis, extraction at pH 8-9 and acetylation was suitable (detection limits 50 ng/ml for FP and 100 ng/ml for AM). Excretion studies showed, that only AM but neither FP nor its specific metabolites were detectable 30-60 h after ingestion of 20 mg of FP. Therefore, misinterpretation can occur. The Abbott TDx FPIA amphetamine/methamphetamine II gave positive results up to 58 h. All the positive immunoassay results could be confirmed by the described GC-MS procedure.

  10. Development of a Smartphone-based reading system for lateral flow immunoassay.

    Science.gov (United States)

    Lee, Sangdae; Kim, Giyoung; Moon, Jihea

    2014-11-01

    This study was conducted to develop and evaluate the performance of the Smartphone-based reading system for the lateral flow immunoassay (LFIA). Smartphone-based reading system consists of a Samsung Galaxy S2 Smartphone, Smartphone application, and a LFIA reader. LFIA reader is composed of the close-up lens with a focal length up to 30 mm, white LED light, lithium polymer battery, and main body. The Smartphone application for image acquisition and data analysis was developed on the Android platform. The standard curve was obtained by plotting the measured P(T)/P(c) or A(T)/A(c) ratio versus Salmonella standard concentration. The mean, standard deviation (SD), recovery, and relative standard deviation (RSD) were also calculated using additional experimental results. These data were compared with that obtained from the benchtop LFIA reader. The LOD in both systems was observed with 10(6) CFU/mL. The results show high accuracy and good reproducibility with a RSD less than 10% in the range of 10(6) to 10(9) CFU/mL. Due to the simple structure, good sensitivity, and high accuracy of the Smartphone-based reading system, this system can be substituted for the benchtop LFIA reader for point-of-care medical diagnostics.

  11. Influence of Technological Treatments on the Functionality of Bifidobacterium lactis INL1, a Breast Milk-Derived Probiotic.

    Science.gov (United States)

    Zacarías, María Florencia; Souza, Tassia Costa; Zaburlín, Natalia; Carmona Cara, Denise; Reinheimer, Jorge; Nicoli, Jacques; Vinderola, Gabriel

    2017-10-01

    The aim of this study is to evaluate the influence of the technological processing on the functionality of the human breast milk probiotic strain Bifidobacterium lactis INL1. In vitro antagonistic activity of B. lactis INL1 was detected for Gram-positive and Gram-negative pathogens. B. lactis INL1 was administered to mice as fresh (F), frozen (Z), spray-dried (S), or lyophilized (L) culture. Immune parameters (IgA, IL-10, and IFN-γ) were determined and histological analysis was performed to assess functionality and protection capacity against Salmonella. In BALB/c mice, F and S cultures induced an increase in the number of IgA-producing cells in the small intestine and IL-10 levels were increased for L culture in the large intestine. In Swiss mice, B. lactis INL1 increased secretory-IgA levels in the small intestine before and after Salmonella infection, both as F or dehydrated culture. Also, an attenuation of damage in the intestinal epithelium and less inflammatory infiltrates were observed in animals that received F and S cultures, whereas in liver only F showed some effect. The anti-inflammatory effect was confirmed in both tissues by myeloperoxidase activity and by IFN-γ levels in the intestinal content. B. lactis INL1 showed inhibitory activity against pathogens and confirmed its probiotic potential in animal models. Technological processing of the probiotic strain affected its functionality. This work provides evidence about the influence of technology on the functionality of probiotics, which may help probiotics and functional food manufacturers to take processing into consideration when assessing the functionality of new strains. © 2017 Institute of Food Technologists®.

  12. Preschoolers’ Technology-Assessed Physical Activity and Cognitive Function: A Cross-Sectional Study

    Directory of Open Access Journals (Sweden)

    Minghui Quan

    2018-05-01

    Full Text Available Early childhood is a critical period for development of cognitive function, but research on the association between physical activity and cognitive function in preschool children is limited and inconclusive. This study aimed to examine the association between technology-assessed physical activity and cognitive function in preschool children. A cross-sectional analysis of baseline data from the Physical Activity and Cognitive Development Study was conducted in Shanghai, China. Physical activity was measured with accelerometers for 7 consecutive days, and cognitive functions were assessed using the Chinese version of Wechsler Young Children Scale of Intelligence (C-WYCSI. Linear regression analyses were used to assess the association between physical activity and cognitive function. A total of 260 preschool children (boys, 144; girls, 116; mean age: 57.2 ± 5.4 months were included in analyses for this study. After adjusting for confounding factors, we found that Verbal Intelligence Quotient, Performance Intelligence Quotient, and Full Intelligence Quotient were significantly correlated with light physical activity, not moderate to vigorous physical activity, in boys. Standardized coefficients were 0.211, 0.218, and 0.242 (all p < 0.05 in three different models, respectively. However, the correlation between physical activity and cognitive functions were not significant in girls (p > 0.05. These findings suggest that cognitive function is apparently associated with light physical activity in boys. Further studies are required to clarify the sex-specific effect on physical activity and cognitive functions.

  13. Functional unit, technological dynamics, and scaling properties for the life cycle energy of residences.

    Science.gov (United States)

    Frijia, Stephane; Guhathakurta, Subhrajit; Williams, Eric

    2012-02-07

    Prior LCA studies take the operational phase to include all energy use within a residence, implying a functional unit of all household activities, but then exclude related supply chains such as production of food, appliances, and household chemicals. We argue that bounding the functional unit to provision of a climate controlled space better focuses the LCA on the building, rather than activities that occur within a building. The second issue explored in this article is how technological change in the operational phase affects life cycle energy. Heating and cooling equipment is replaced at least several times over the lifetime of a residence; improved efficiency of newer equipment affects life cycle energy use. The third objective is to construct parametric models to describe LCA results for a family of related products. We explore these three issues through a case study of energy use of residences: one-story and two-story detached homes, 1,500-3,500 square feet in area, located in Phoenix, Arizona, built in 2002 and retired in 2051. With a restricted functional unit and accounting for technological progress, approximately 30% of a building's life cycle energy can be attributed to materials and construction, compared to 0.4-11% in previous studies.

  14. A sensitive chemiluminescent immunoassay to detect Chromotrope FB (Chr FB) in foods.

    Science.gov (United States)

    Xu, Kun; Long, Hao; Xing, Rongge; Yin, Yongmei; Eremin, Sergei A; Meng, Meng; Xi, Rimo

    2017-03-01

    Chromotrope FB (Chr FB) is a synthetic azo dye permitted for use in foods and medicines. An acceptable daily intake (ADI) of Chr FB was 0-0.5mg/kg in China. In this study, we synthesized a Chr FB hapten with an amino group to prepare its artificial immunogen. Polyclonal antibodies obtained from New Zealand rabbits were applied to develop an indirect competitive chemiluminescent immunoassay (icCLIA) to detect Chr FB in foods. A horseradish peroxidase (HRP)-luminol-H 2 O 2 system was used to yield CL signal with p-iodophenol as an enhancement reagent. The method showed good specificity towards Chr FB and could detect as low as 0.02ngmL -1 Chr FB in buffer, 0.07ngg -1 in yoghurt candy, 0.07ngg -1 in vitamin drink and 0.13ngg -1 in bread. Compared with HPLC method, the proposed method is more sensitive by two orders of magnitude. The accuracy and precision of this method are acceptable and comparable with HPLC method. Therefore, the proposed method could be used for rapid screening of Chr FB in the mentioned foodstuffs. Copyright © 2016. Published by Elsevier B.V.

  15. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.

    Science.gov (United States)

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-12-01

    To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.

  16. Development of flow-through and dip-stick immunoassays for screening of sulfonamide residues.

    Science.gov (United States)

    Zhang, Hongyan; Zhang, Yan; Wang, Shuo

    2008-08-20

    Two formats of membrane-based competitive enzyme immunoassays (flow-through and dip-stick) have been developed for the screening of sulfonamide residues in pig muscle and milk. Membrane was coated with anti-sulfonamide antibody and a sulfonamide hapten D2-horseradish peroxidase (HRP) conjugant was used as the labeled antigen for competitive assay of sulfonamides. Visual detection limits of the flow-through or dip-stick assay were 1-5 microg L(-1) or 1-10 microg L(-1) in buffer for seven sulfonamides, respectively. Assay validation was performed using samples spiked with single sulfonamide, spiked samples were tested using the developed strip assays and results were compared with those obtained by a validated high-performance liquid chromatograph (HPLC) method. Results showed that the two strip assays were correlated well with HPLC, respectively. With assay times of 5 min (flow-through) and 15 min (dip-stick), these rapid tests could offer simple, rapid and cost-effective on-site screening tools to detect sulfonamides in pig muscle (flow-through or dip-stick) or milk (only dip-stick).

  17. Utilization of Educational Innovations and Technology in Research and Extension Functions of State Universities

    Directory of Open Access Journals (Sweden)

    Rosalinda M. Comia

    2017-11-01

    Full Text Available The study focused on the extent of utilization of the educational innovations and technology in research and extension functions of SUs. The descriptive design, triangulation method, and purposive sampling were applied in this study. The findings revealed that majority of the respondents are married adults and master’s degree graduates with education as their area of specialization. They are permanent in status and have considerable years in the University serving as research or extension officer. Research of SUs have common research thrusts in terms of environment and natural resources management but differ in their own respective agenda; similarly the SUs share common extension thrusts and concerns but differ in their programs, activities and projects related to community services. Commonly encountered problems concern inadequate funds and inability to access the available technology. Officers utilized educational innovations on research and extension to a moderate extent but software and hardware were utilized to a great extent; likewise internet-based communication was utilized to a great extent for research but used moderately for extension. This implies that compared to research, most of the extension functions do not require the use of internet-based communication. From the results of the study, it was recommended that review of the existing allocation of funds for technology development may be done to improve the existing hardware, software and communication facilities.

  18. The role of the autoimmunity laboratory in autoimmune diseases

    Directory of Open Access Journals (Sweden)

    SS Hasson

    2012-04-01

    Full Text Available Laboratory testing is of great value when evaluating a patient with a suspected autoimmune disease. The results can confirm a diagnosis, estimate disease severity, aid in assessing prognosis and are useful to follow disease activity. Components of the laboratory exam include complete blood count with differential, comprehensive metabolic panel, inflammatory markers, autoantibodies, and flow cytometry. Currently, autoimmunity laboratories are very vibrant owing to the constant and increasing availability of new tests, mainly due to the detection of new autoantibodies. The main characteristic that differentiates the autoimmunity laboratory from other laboratories is the use of immunoassays such as enzyme-linked immunosorbent assay (ELISA, as basic techniques which determines antibodies (autoantibodies and not antigens. For this reason, immunoassay techniques must employ antigens as reagents. However, over the last few years, a significant trend at autoimmunity laboratories has been the gradual replacement of immunofluorescence microscopy by immunoassay. Nowadays the revolution of new technology has taken place significantly, for examples; recombinant DNA technology has allowed the production of large quantities of antigens for autoantibody analysis. Flow cytometry for the analysis of microsphere-based immunoassays allows the simultaneous measurement of several autoantibodies. In the same way, autoantigen microarrays provide a practical means to analyse biological fluids in the search for a high number of autoantibodies. We are now at the beginning of an era of multiplexed analysis, with a high capacity of autoantibody specificities. The future tendency in this field will include immunoassays with greater analytical sensitivity, specificity, simultaneous multiplexed capability, the use of protein microarrays, and the use of other technologies such as microfluidics.

  19. Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing

    OpenAIRE

    Halling, V. W.; Jones, M. F.; Bestrom, J. E.; Wold, A. D.; Rosenblatt, J. E.; Smith, T. F.; Cockerill, F. R.

    1999-01-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTI...

  20. Independent effects of both right and left ventricular function on plasma brain natriuretic peptide

    DEFF Research Database (Denmark)

    Vogelsang, Thomas Wiis; Jensen, Ruben J; Monrad, Astrid L

    2007-01-01

    BACKGROUND: Brain natriuretic peptide (BNP) is increased in heart failure; however, the relative contribution of the right and left ventricles is largely unknown. AIM: To investigate if right ventricular function has an independent influence on plasma BNP concentration. METHODS: Right (RVEF), left......, which is a strong prognostic marker in heart failure, independently depends on both left and right ventricular systolic function. This might, at least in part, explain why BNP holds stronger prognostic value than LVEF alone....... ventricular ejection fraction (LVEF), and left ventricular end-diastolic volume index (LVEDVI) were determined in 105 consecutive patients by first-pass radionuclide ventriculography (FP-RNV) and multiple ECG-gated equilibrium radionuclide ventriculography (ERNV), respectively. BNP was analyzed by immunoassay...