WorldWideScience

Sample records for full-volume three-dimensional transient

  1. NUMERICAL METHOD OF MIXED FINITE VOLUME-MODIFIED UPWIND FRACTIONAL STEP DIFFERENCE FOR THREE-DIMENSIONAL SEMICONDUCTOR DEVICE TRANSIENT BEHAVIOR PROBLEMS

    Institute of Scientific and Technical Information of China (English)

    Yirang YUAN; Qing YANG; Changfeng LI; Tongjun SUN

    2017-01-01

    Transient behavior of three-dimensional semiconductor device with heat conduction is described by a coupled mathematical system of four quasi-linear partial differential equations with initial-boundary value conditions.The electric potential is defined by an elliptic equation and it appears in the following three equations via the electric field intensity.The electron concentration and the hole concentration are determined by convection-dominated diffusion equations and the temperature is interpreted by a heat conduction equation.A mixed finite volume element approximation,keeping physical conservation law,is used to get numerical values of the electric potential and the accuracy is improved one order.Two concentrations and the heat conduction are computed by a fractional step method combined with second-order upwind differences.This method can overcome numerical oscillation,dispersion and decreases computational complexity.Then a three-dimensional problem is solved by computing three successive one-dimensional problems where the method of speedup is used and the computational work is greatly shortened.An optimal second-order error estimate in L2 norm is derived by using prior estimate theory and other special techniques of partial differential equations.This type of mass-conservative parallel method is important and is most valuable in numerical analysis and application of semiconductor device.

  2. Development of three dimensional transient analysis code STTA for SCWR core

    International Nuclear Information System (INIS)

    Wang, Lianjie; Zhao, Wenbo; Chen, Bingde; Yao, Dong; Yang, Ping

    2015-01-01

    Highlights: • A coupled three dimensional neutronics/thermal-hydraulics code STTA is developed for SCWR core transient analysis. • The Dynamic Link Libraries method is adopted for coupling computation for SCWR multi-flow core transient analysis. • The NEACRP-L-335 PWR benchmark problems are studied to verify STTA. • The SCWR rod ejection problems are studied to verify STTA. • STTA meets what is expected from a code for SCWR core 3-D transient preliminary analysis. - Abstract: A coupled three dimensional neutronics/thermal-hydraulics code STTA (SCWR Three dimensional Transient Analysis code) is developed for SCWR core transient analysis. Nodal Green’s Function Method based on the second boundary condition (NGFMN-K) is used for solving transient neutron diffusion equation. The SCWR sub-channel code ATHAS is integrated into NGFMN-K through the serial integration coupling approach. The NEACRP-L-335 PWR benchmark problem and SCWR rod ejection problems are studied to verify STTA. Numerical results show that the PWR solution of STTA agrees well with reference solutions and the SCWR solution is reasonable. The coupled code can be well applied to the core transients and accidents analysis with 3-D core model during both subcritical pressure and supercritical pressure operation

  3. A DETERMINISTIC METHOD FOR TRANSIENT, THREE-DIMENSIONAL NUETRON TRANSPORT

    International Nuclear Information System (INIS)

    S. GOLUOGLU, C. BENTLEY, R. DEMEGLIO, M. DUNN, K. NORTON, R. PEVEY I.SUSLOV AND H.L. DODDS

    1998-01-01

    A deterministic method for solving the time-dependent, three-dimensional Boltzmam transport equation with explicit representation of delayed neutrons has been developed and evaluated. The methodology used in this study for the time variable of the neutron flux is known as the improved quasi-static (IQS) method. The position, energy, and angle-dependent neutron flux is computed deterministically by using the three-dimensional discrete ordinates code TORT. This paper briefly describes the methodology and selected results. The code developed at the University of Tennessee based on this methodology is called TDTORT. TDTORT can be used to model transients involving voided and/or strongly absorbing regions that require transport theory for accuracy. This code can also be used to model either small high-leakage systems, such as space reactors, or asymmetric control rod movements. TDTORT can model step, ramp, step followed by another step, and step followed by ramp type perturbations. It can also model columnwise rod movement can also be modeled. A special case of columnwise rod movement in a three-dimensional model of a boiling water reactor (BWR) with simple adiabatic feedback is also included. TDTORT is verified through several transient one-dimensional, two-dimensional, and three-dimensional benchmark problems. The results show that the transport methodology and corresponding code developed in this work have sufficient accuracy and speed for computing the dynamic behavior of complex multidimensional neutronic systems

  4. Transient Three-Dimensional Side Load Analysis of a Film Cooled Nozzle

    Science.gov (United States)

    Wang, Ten-See; Guidos, Mike

    2008-01-01

    Transient three-dimensional numerical investigations on the side load physics for an engine encompassing a film cooled nozzle extension and a regeneratively cooled thrust chamber, were performed. The objectives of this study are to identify the three-dimensional side load physics and to compute the associated aerodynamic side load using an anchored computational methodology. The computational methodology is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, and a transient inlet history based on an engine system simulation. Ultimately, the computational results will be provided to the nozzle designers for estimating of effect of the peak side load on the nozzle structure. Computations simulating engine startup at ambient pressures corresponding to sea level and three high altitudes were performed. In addition, computations for both engine startup and shutdown transients were also performed for a stub nozzle, operating at sea level. For engine with the full nozzle extension, computational result shows starting up at sea level, the peak side load occurs when the lambda shock steps into the turbine exhaust flow, while the side load caused by the transition from free-shock separation to restricted-shock separation comes at second; and the side loads decreasing rapidly and progressively as the ambient pressure decreases. For the stub nozzle operating at sea level, the computed side loads during both startup and shutdown becomes very small due to the much reduced flow area.

  5. Impact of anisotropic slip on transient three dimensional MHD flow of ferrofluid over an inclined radiate stretching surface

    Directory of Open Access Journals (Sweden)

    A.M. Rashad

    2017-04-01

    Full Text Available The present study explores the impact of anistropic slip on transient three dimensional MHD flow of Cobalt-kerosene ferrofluid over an inclined radiate stretching surface. The governing partial differential equations for this study are solved by the Thomas algorithm with finite-difference type. The impacts of several significant parameters on flow and heat transfer characteristics are exhibited graphically. The conclusion is revealed that the local Nusselt number is significantly promoted due to influence of thermal radiation whereas diminished with elevating the solid volume fraction, magnet parameter and slip factors. Further, the skin friction coefficients visualizes a considerable enhancement with boosting the magnet and radiation parameters, but a prominent reduction is recorded by elevating the solid volume fraction and slip factors.

  6. Three dimensional neutronic/thermal-hydraulic coupled simulation of MSR in transient state condition

    International Nuclear Information System (INIS)

    Zhou, Jianjun; Zhang, Daling; Qiu, Suizheng; Su, Guanghui; Tian, Wenxi; Wu, Yingwei

    2015-01-01

    Highlights: • Developed a three dimensional neutronic/thermal-hydraulic coupled transient analysis code for MSR. • Investigated the neutron distribution and thermal-hydraulic characters of the core under transient condition. • Analyzed three different transient conditions of inlet temperature drop, reactivity jump and pump coastdown. - Abstract: MSR (molten salt reactor) use liquid molten salt as coolant and fuel solvent, which was the only one liquid reactor of six Generation IV reactor types. As a liquid reactor the physical property of reactor was significantly influenced by fuel salt flow and the conventional analysis methods applied in solid fuel reactors are not applicable for this type of reactors. The present work developed a three dimensional neutronic/thermal-hydraulic coupled code investigated the neutronics and thermo-hydraulics characteristics of the core in transient condition based on neutron diffusion theory and numerical heat transfer. The code consists of two group neutron diffusion equations for fast and thermal neutron fluxes and six group balance equations for delayed neutron precursors. The code was separately validated by neutron benchmark and flow and heat transfer benchmark. Three different transient conditions was analyzed with inlet temperature drop, reactivity jump and pump coastdown. The results provide some valuable information in design and research this kind of reactor

  7. Three dimensional neutronic/thermal-hydraulic coupled simulation of MSR in transient state condition

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Jianjun [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China); College of Mechanical and Power Engineering, China Three Gorges University, No 8, Daxue road, Yichang, Hubei 443002 (China); Zhang, Daling, E-mail: dlzhang@mail.xjtu.edu.cn [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China); Qiu, Suizheng; Su, Guanghui; Tian, Wenxi; Wu, Yingwei [School of Nuclear Science and Technology, Xi’an Jiaotong University, Xianning Road, 28, Xi’an 710049, Shaanxi (China)

    2015-02-15

    Highlights: • Developed a three dimensional neutronic/thermal-hydraulic coupled transient analysis code for MSR. • Investigated the neutron distribution and thermal-hydraulic characters of the core under transient condition. • Analyzed three different transient conditions of inlet temperature drop, reactivity jump and pump coastdown. - Abstract: MSR (molten salt reactor) use liquid molten salt as coolant and fuel solvent, which was the only one liquid reactor of six Generation IV reactor types. As a liquid reactor the physical property of reactor was significantly influenced by fuel salt flow and the conventional analysis methods applied in solid fuel reactors are not applicable for this type of reactors. The present work developed a three dimensional neutronic/thermal-hydraulic coupled code investigated the neutronics and thermo-hydraulics characteristics of the core in transient condition based on neutron diffusion theory and numerical heat transfer. The code consists of two group neutron diffusion equations for fast and thermal neutron fluxes and six group balance equations for delayed neutron precursors. The code was separately validated by neutron benchmark and flow and heat transfer benchmark. Three different transient conditions was analyzed with inlet temperature drop, reactivity jump and pump coastdown. The results provide some valuable information in design and research this kind of reactor.

  8. [Assessment of the right ventricular function in healthy volunteers with one beat full-volume real-time three-dimensional echocardiography].

    Science.gov (United States)

    Zhu, Wei-hong; Zhang, Jin; Tong, Kai; Zhi, Guang; He, Kun-lun

    2012-08-01

    To determine the normal value of right ventricle using one beat full-volume real-time three-dimensional echocardiography (RT-3DE) and assess the feasibility of this technique. One beat full volume images were acquired at the apical 4 chamber view in 129 healthy volunteers. The right and left ventricular volumes were examined with the eSie LVA and RVA. The subjects were divided into 2 gender groups (male and female) and 3 age groups (20 - 39 years old, 40 - 59 years old, 60 years old and above). Adequate data were obtained in 129 subjects. The RV-EDV was (92.4 ± 21.3) ml, RV-ESV (34.6 ± 9.2) ml, RV-SV (57.8 ± 13.9) ml, RV-EF (62.5 ± 5.0) ml. EDV, ESV, and EF were significant different while SV was similar between RV and LV (all P Right ventricle function can be measured noninvasively by RT-3DE with high feasibility. This novel method contributes to the detailed study of right heart function in various cardiovascular diseases.

  9. Environmental, Transient, Three-Dimensional, Hydrothermal, Mass Transport Code - FLESCOT

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Yasuo [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bao, Jie [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glass, Kevin A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eyler, L. L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Okumura, Masahiko [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-28

    The purpose of the project was to modify and apply the transient, three-dimensional FLESCOT code to be able to effectively simulate cesium behavior in Fukushima lakes/dam reservoirs, river mouths, and coastal areas. The ultimate objective of the FLESCOT simulation is to predict future changes of cesium accumulation in Fukushima area reservoirs and costal water. These evaluation results will assist ongoing and future environmental remediation activities and policies in a systematic and comprehensive manner.

  10. A simplified transient three-dimensional model for estimating the thermal performance of the vapor chambers

    International Nuclear Information System (INIS)

    Chen, Y.-S.; Chien, K.-H.; Wang, C.-C.; Hung, T.-C.; Pei, B.-S.

    2006-01-01

    The vapor chambers (flat plate heat pipes) have been applied on the electronic cooling recently. To satisfy the quick-response requirement of the industries, a simplified transient three-dimensional linear model has been developed and tested in this study. In the proposed model, the vapor is assumed as a single interface between the evaporator and condenser wicks, and this assumption enables the vapor chamber to be analyzed by being split into small control volumes. Comparing with the previous available results, the calculated transient responses have shown good agreements with the existing results. For further validation of the proposed model, a water-cooling experiment was conducted. In addition to the vapor chamber, the heating block is also taken into account in the simulation. It is found that the inclusion of the capacitance of heating block shows a better agreement with the measurements

  11. Transient simulation of hydropower station with consideration of three-dimensional unsteady flow in turbine

    International Nuclear Information System (INIS)

    Huang, W D; Fan, H G; Chen, N X

    2012-01-01

    To study the interaction between the transient flow in pipe and the unsteady turbulent flow in turbine, a coupled model of the transient flow in the pipe and three-dimensional unsteady flow in the turbine is developed based on the method of characteristics and the fluid governing equation in the accelerated rotational relative coordinate. The load-rejection process under the closing of guide vanes of the hydraulic power plant is simulated by the coupled method, the traditional transient simulation method and traditional three-dimensional unsteady flow calculation method respectively and the results are compared. The pressure, unit flux and rotation speed calculated by three methods show a similar change trend. However, because the elastic water hammer in the pipe and the pressure fluctuation in the turbine have been considered in the coupled method, the increase of pressure at spiral inlet is higher and the pressure fluctuation in turbine is stronger.

  12. Transient simulation of hydropower station with consideration of three-dimensional unsteady flow in turbine

    Science.gov (United States)

    Huang, W. D.; Fan, H. G.; Chen, N. X.

    2012-11-01

    To study the interaction between the transient flow in pipe and the unsteady turbulent flow in turbine, a coupled model of the transient flow in the pipe and three-dimensional unsteady flow in the turbine is developed based on the method of characteristics and the fluid governing equation in the accelerated rotational relative coordinate. The load-rejection process under the closing of guide vanes of the hydraulic power plant is simulated by the coupled method, the traditional transient simulation method and traditional three-dimensional unsteady flow calculation method respectively and the results are compared. The pressure, unit flux and rotation speed calculated by three methods show a similar change trend. However, because the elastic water hammer in the pipe and the pressure fluctuation in the turbine have been considered in the coupled method, the increase of pressure at spiral inlet is higher and the pressure fluctuation in turbine is stronger.

  13. COMMIX-PPC: A three-dimensional transient multicomponent computer program for analyzing performance of power plant condensers

    International Nuclear Information System (INIS)

    Chien, T.H.; Domanus, H.M.; Sha, W.T.

    1993-02-01

    The COMMIX-PPC computer pregrain is an extended and improved version of earlier COMMIX codes and is specifically designed for evaluating the thermal performance of power plant condensers. The COMMIX codes are general-purpose computer programs for the analysis of fluid flow and heat transfer in complex Industrial systems. In COMMIX-PPC, two major features have been added to previously published COMMIX codes. One feature is the incorporation of one-dimensional equations of conservation of mass, momentum, and energy on the tube stile and the proper accounting for the thermal interaction between shell and tube side through the porous-medium approach. The other added feature is the extension of the three-dimensional conservation equations for shell-side flow to treat the flow of a multicomponent medium. COMMIX-PPC is designed to perform steady-state and transient. Three-dimensional analysis of fluid flow with heat transfer tn a power plant condenser. However, the code is designed in a generalized fashion so that, with some modification, it can be used to analyze processes in any heat exchanger or other single-phase engineering applications. Volume I (Equations and Numerics) of this report describes in detail the basic equations, formulation, solution procedures, and models for a phenomena. Volume II (User's Guide and Manual) contains the input instruction, flow charts, sample problems, and descriptions of available options and boundary conditions

  14. Volume scanning three-dimensional display with an inclined two-dimensional display and a mirror scanner

    Science.gov (United States)

    Miyazaki, Daisuke; Kawanishi, Tsuyoshi; Nishimura, Yasuhiro; Matsushita, Kenji

    2001-11-01

    A new three-dimensional display system based on a volume-scanning method is demonstrated. To form a three-dimensional real image, an inclined two-dimensional image is rapidly moved with a mirror scanner while the cross-section patterns of a three-dimensional object are displayed sequentially. A vector-scan CRT display unit is used to obtain a high-resolution image. An optical scanning system is constructed with concave mirrors and a galvanometer mirror. It is confirmed that three-dimensional images, formed by the experimental system, satisfy all the criteria for human stereoscopic vision.

  15. Full-Volume, Three-Dimensional, Transient Measurements of Bubbly Flows Using Particle Tracking Velocimetry and Shadow Image Velocimetry Coupled with Pattern Recognition Techniques

    International Nuclear Information System (INIS)

    Yassin Hassan

    2001-01-01

    Develop a state-of-the-art non-intrusive diagnostic tool to perform simultaneous measurements of both the temporal and three-dimensional spatial velocity of the two phases of a bubbly flow. These measurements are required to provide a foundation for studying the constitutive closure relations needed in computational fluid dynamics and best-estimate thermal hydraulic codes employed in nuclear reactor safety analysis and severe accident simulation. Such kinds of full-field measurements are not achievable through the commonly used point-measurement techniques, such as hot wire, conductance probe, laser Doppler anemometry, etc. The results can also be used in several other applications, such as the dynamic transport of pollutants in water or studies of the dispersion of hazardous waste

  16. Point kinetics improvements to evaluate three-dimensional effects in transients calculation

    International Nuclear Information System (INIS)

    Castellotti, U.

    1987-01-01

    A calculation method, which considers the flux axial perturbations in the parameters related to the reactivity within a point kinetics model, is described. The method considered uses axial factors of consideration which act on the thermohydraulic variables included in the reactivity calculation. The PUMA three-dimensional code as reference model for the comparisons, is used. The limitations inherent to the reactivity balance of the point models used in the transients calculation, are given. (Author)

  17. Secure data storage by three-dimensional absorbers in highly scattering volume medium

    International Nuclear Information System (INIS)

    Matoba, Osamu; Matsuki, Shinichiro; Nitta, Kouichi

    2008-01-01

    A novel data storage in a volume medium with highly scattering coefficient is proposed for data security application. Three-dimensional absorbers are used as data. These absorbers can not be measured by interferometer when the scattering in a volume medium is strong enough. We present a method to reconstruct three-dimensional absorbers and present numerical results to show the effectiveness of the proposed data storage.

  18. TMCC: a transient three-dimensional neutron transport code by the direct simulation method - 222

    International Nuclear Information System (INIS)

    Shen, H.; Li, Z.; Wang, K.; Yu, G.

    2010-01-01

    A direct simulation method (DSM) is applied to solve the transient three-dimensional neutron transport problems. DSM is based on the Monte Carlo method, and can be considered as an application of the Monte Carlo method in the specific type of problems. In this work, the transient neutronics problem is solved by simulating the dynamic behaviors of neutrons and precursors of delayed neutrons during the transient process. DSM gets rid of various approximations which are always necessary to other methods, so it is precise and flexible in the requirement of geometric configurations, material compositions and energy spectrum. In this paper, the theory of DSM is introduced first, and the numerical results obtained with the new transient analysis code, named TMCC (Transient Monte Carlo Code), are presented. (authors)

  19. K-FIX: a computer program for transient, two-dimensional, two-fluid flow. THREED: an extension of the K-FIX code for three-dimensional calculations

    International Nuclear Information System (INIS)

    Rivard, W.C.; Torrey, M.D.

    1978-10-01

    The transient, two-dimensional, two-fluid code K-FIX has been extended to perform three-dimensional calculations. This capability is achieved by adding five modification sets of FORTRAN statements to the basic two-dimensional code. The modifications are listed and described, and a complete listing of the three-dimensional code is provided. Results of an example problem are provided for verification

  20. Two-dimensional transient thermal analysis of a fuel rod by finite volume method

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Rhayanne Yalle Negreiros; Silva, Mário Augusto Bezerra da; Lira, Carlos Alberto de Oliveira, E-mail: ryncosta@gmail.com, E-mail: mabs500@gmail.com, E-mail: cabol@ufpe.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear

    2017-07-01

    One of the greatest concerns when studying a nuclear reactor is the warranty of safe temperature limits all over the system at all time. The preservation of core structure along with the constraint of radioactive material into a controlled system are the main focus during the operation of a reactor. The purpose of this paper is to present the temperature distribution for a nominal channel of the AP1000 reactor developed by Westinghouse Co. during steady-state and transient operations. In the analysis, the system was subjected to normal operation conditions and then to blockages of the coolant flow. The time necessary to achieve a new safe stationary stage (when it was possible) was presented. The methodology applied in this analysis was based on a two-dimensional survey accomplished by the application of Finite Volume Method (FVM). A steady solution is obtained and compared with an analytical analysis that disregard axial heat transport to determine its relevance. The results show the importance of axial heat transport consideration in this type of study. A transient analysis shows the behavior of the system when submitted to coolant blockage at channel's entrance. Three blockages were simulated (10%, 20% and 30%) and the results show that, for a nominal channel, the system can still be considerate safe (there's no bubble formation until that point). (author)

  1. Three-dimensional inverse transient heat transfer analysis of thick functionally graded plates

    Energy Technology Data Exchange (ETDEWEB)

    Haghighi, M.R. Golbahar; Malekzadeh, P. [Department of Mechanical Engineering, School of Engineering, Persian Gulf University, Bushehr 75168 (Iran); Eghtesad, M. [Department of Mechanical Engineering, School of Engineering, Shiraz University, Shiraz 71348-51154 (Iran); Necsulescu, D.S. [Department of Mechanical Engineering, Faculty of Engineering, University of Ottawa, Ottawa, Ontario (Canada)

    2009-03-15

    In this paper, a three-dimensional transient inverse heat conduction (IHC) procedure is presented to estimate the unknown boundary heat flux of thick functionally graded (FG) plates. For this purpose, the conjugate gradient method (CGM) in conjunction with adjoint problem is used. A recently developed three-dimensional efficient hybrid method is employed to solve variable-coefficient initial-boundary-value differential equations of direct problem as a part of the inverse solution. The accuracy of the inverse analysis is examined by simulating the exact and noisy data for problems with different types of boundary conditions and material properties. In addition to rectangular domain, skew plates are considered. The results obtained show good accuracy for the estimation of boundary heat fluxes. (author)

  2. Transient analysis of cutoff waveguide antenna in three-dimensional space

    International Nuclear Information System (INIS)

    Kashiwa, Tatsuya; Yoshida, Norinobu; Fukai, Ichiro

    1986-01-01

    Recently, the exciting system for electric power heating as seen in nuclear fusion plasma heating and medical purpose has been actively studied and developed. Since such system treats basically a neighborhood field, various problems unlike conventional exciting system for communication arise. In such situation, the structure having the waveguides of simple and robust construction as the main body has been proposed. In this exciting system including the condition of media, the complex distribution of a neighborhood field based on a three-dimensional structure exerts an important effect on the characteristics. Especially in large power excitation, the higher mode of relatively small power distribution cannot be neglected. Besides, also a transient field distribution exerts an important effect on the characteristics, and the time response analysis is required. In this analysis, by the three-dimensional time response analysis method using Bergeron method, the unified analysis of the total system comprising a cutoff waveguide, a coaxial exciting part and a heating region was carried out for determining a radiation neighborhood electromagnetic field by a cutoff waveguide antenna. (Kako, I.)

  3. NASA-VOF3D: A three-dimensional computer program for incompressible flows with free surfaces

    Science.gov (United States)

    Torrey, M. D.; Mjolsness, R. C.; Stein, L. R.

    1987-07-01

    Presented is the NASA-VOF3D three-dimensional, transient, free-surface hydrodynamics program. This three-dimensional extension of NASA-VOF2D will, in principle, permit treatment in full three-dimensional generality of the wide variety of applications that could be treated by NASA-VOF2D only within the two-dimensional idealization. In particular, it, like NASA-VOF2D, is specifically designed to calculate confined flows in a low g environment. The code is presently restricted to cylindrical geometry. The code is based on the fractional volume-of-fluid method and allows multiple free surfaces with surface tension and wall adhesion. It also has a partial cell treatment that allows curved boundaries and internal obstacles. This report provides a brief discussion of the numerical method, a code listing, and some sample problems.

  4. Full three-dimensional isotropic transformation media

    International Nuclear Information System (INIS)

    García-Meca, C; Martí, J; Martínez, A; Ortuño, R

    2014-01-01

    We present a method that enables the implementation of full three-dimensional (3D) transformation media with minimized anisotropy. It is based on a special kind of shape-preserving mapping and a subsequent optimization process. For sufficiently smooth transformations, the resulting anisotropy can be neglected, paving the way for practically realizable 3D devices. The method is independent of the considered wave phenomenon and can thus be applied to any field for which a transformational technique exists, such as acoustics or thermodynamics. Full 3D isotropy has an additional important implication for optical transformation media, as it eliminates the need for magnetic materials in many situations. To illustrate the potential of the method, we design 3D counterparts of transformation-based electromagnetic squeezers and bends. (paper)

  5. Verification of a three-dimensional neutronics model based on multi-point kinetics equations for transient problems

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Seok; Kim, Hyun Dae; Yeom, Choong Sub [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    A computer code for solving the three-dimensional reactor neutronic transient problems utilizing multi-point reactor kinetics equations recently developed has been developed. For evaluating its applicability, the code has been tested with typical 3-D LWR and CANDU reactor transient problems. The performance of the method and code has been compared with the results by fine and coarse meshes computer codes employing the direct methods.

  6. TEMPEST: A three-dimensional time-dependent computer program for hydrothermal analysis: Volume 1, Numerical methods and input instructions

    International Nuclear Information System (INIS)

    Trent, D.S.; Eyler, L.L.; Budden, M.J.

    1983-09-01

    This document describes the numerical methods, current capabilities, and the use of the TEMPEST (Version L, MOD 2) computer program. TEMPEST is a transient, three-dimensional, hydrothermal computer program that is designed to analyze a broad range of coupled fluid dynamic and heat transfer systems of particular interest to the Fast Breeder Reactor thermal-hydraulic design community. The full three-dimensional, time-dependent equations of motion, continuity, and heat transport are solved for either laminar or turbulent fluid flow, including heat diffusion and generation in both solid and liquid materials. 10 refs., 22 figs., 2 tabs

  7. Research of three-dimensional transient reactivity feedback in fast reactor

    International Nuclear Information System (INIS)

    Xu Li; Shi Gong; Ma Dayuan; Yu Hong

    2013-01-01

    To solve the three-dimensional time-spatial kinetics feedback problems in fast reactor, a mathematical model of the direct reactivity feedback was proposed. Based on the NAS code for fast reactor and the reactivity feedback mechanism, a feedback model which combined the direct reactivity feedback and feedback reflected by the cross section variation was provided for the transient calculation. Furthermore, the fast reactor group collapsing system was added to the code, thus the real time group collapsing calculation could be realized. The isothermal elevated temperature test of CEFR was simulated by using the code. By comparing the calculation result with the test result of the temperature reactivity coefficient, the validity of the model and the code is verified. (authors)

  8. Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods

    International Nuclear Information System (INIS)

    Montaudon, M.; Laffon, E.; Berger, P.; Corneloup, O.; Latrabe, V.; Laurent, F.

    2006-01-01

    This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method. (orig.)

  9. COMMIX-1A: a three-dimensional transient single-phase computer program for thermal hydraulic analysis of single and multicomponent systems. Volume I: users manual

    International Nuclear Information System (INIS)

    Domanus, H.M.; Schmitt, R.C.; Sha, W.T.; Shah, V.L.

    1983-12-01

    The COMMIX-1A computer program is an updated and improved version of COMMIX-1 designed to analyze steady-state/transient, single-phase, three-dimensional fluid flow with heat transfer in reactor components and multicomponent systems. A new porous-media formulation via local volume averaging has been derived and employed in the COMMIX code. The concepts of volume porosity, directional surface permeability, distributed resistance, and distributed heat source or sink is used in the new porous-media formulation to model a flow domain with stationary structures. The concept of directional surface permeability is new and greatly facilitates modeling of velocity and temperature fields in anisotropic media. The new porous-media formulation represents the first unified approach to thermal-hydraulic analysis. It is now possible to perform a multidimensional thermal-hydraulic simulation of either a single component, such as a rod bundle, reactor plenum, piping system, heat exchanger, etc., or a multicomponent system that is a combination of these components. The conservation equations of mass, momentum, and energy based on the new porous-media formulation are solved as a boundary-value problem in space and an initial-value problem in time. Two other unique features provided in the COMMIX-1A code are (1) two solution procedures - a semi-implicit procedure modified from ICE and a fully-implicit procedure, named SIMPLEST-ANL, similar to the SIMPLE/SIMPLER algorithms - available a user's option and (2) a geometrical package capable of approximating many geometries. This report (Volume I) describes in detail the basic equations, formulations, solution procedures, flow charts, rebalancing scheme for faster convergence, options available to users, models to describe the auxiliary phenomena, input instructions, and two sample problems. The Volume II assembles and summarizes the results of many simulations that have been performed with COMMIX-1A computer program

  10. A general methodology for three-dimensional analysis of variation in target volume delineation

    NARCIS (Netherlands)

    Remeijer, P.; Rasch, C.; Lebesque, J. V.; van Herk, M.

    1999-01-01

    A generic method for three-dimensional (3-D) evaluation of target volume delineation in multiple imaging modalities is presented. The evaluation includes geometrical and statistical methods to estimate observer differences and variability in defining the Gross Tumor Volume (GTV) in relation to the

  11. Three dimensional Free Vibration and Transient Analysis of Two Directional Functionally Graded Thick Cylindrical Panels Under Impact Loading

    Directory of Open Access Journals (Sweden)

    Hassan Zafarmand

    Full Text Available AbstractIn this paper three dimensional free vibration and transient response of a cylindrical panel made of two directional functionally graded materials (2D-FGMs based on three dimensional equations of elasticity and subjected to internal impact loading is considered. Material properties vary through both radial and axial directions continuously. The 3D graded finite element method (GFEM based on Rayleigh-Ritz energy formulation and Newmark direct integration method has been applied to solve the equations in space and time domains. The fundamental normalized natural frequency, time history of displacements and stresses in three directions and velocity of radial stress wave propagation for various values of span angel of cylindrical panel and different power law exponents have been investigated. The present results show that using 2D-FGMs leads to a more flexible design than conventional 1D-FGMs. The GFEM solution have been compared with the results of an FG thick hollow cylinder and an FG curved panel, where a good agreement between them is observed.

  12. FINITE VOLUME METHOD FOR SOLVING THREE-DIMENSIONAL ELECTRIC FIELD DISTRIBUTION

    Directory of Open Access Journals (Sweden)

    Paţiuc V.I.

    2011-04-01

    Full Text Available The paper examines a new approach to finite volume method which is used to calculate the electric field spatially homogeneous three-dimensional environment. It is formulated the problem Dirihle with building of the computational grid on base of space partition, which is known as Delone triangulation with the use of Voronoi cells. It is proposed numerical algorithm for calculating the potential and electric field strength in the space formed by a cylinder placed in the air. It is developed algorithm and software which were for the case, when the potential on the inner surface of the cylinder has been assigned and on the outer surface and the bottom of cylinder it was assigned zero potential. There are presented results of calculations of distribution in the potential space and electric field strength.

  13. Transient Three-Dimensional Analysis of Side Load in Liquid Rocket Engine Nozzles

    Science.gov (United States)

    Wang, Ten-See

    2004-01-01

    Three-dimensional numerical investigations on the nozzle start-up side load physics were performed. The objective of this study is to identify the three-dimensional side load physics and to compute the associated aerodynamic side load using an anchored computational methodology. The computational methodology is based on an unstructured-grid, and pressure-based computational fluid dynamics formulation, and a simulated inlet condition based on a system calculation. Finite-rate chemistry was used throughout the study so that combustion effect is always included, and the effect of wall cooling on side load physics is studied. The side load physics captured include the afterburning wave, transition from free- shock to restricted-shock separation, and lip Lambda shock oscillation. With the adiabatic nozzle, free-shock separation reappears after the transition from free-shock separation to restricted-shock separation, and the subsequent flow pattern of the simultaneous free-shock and restricted-shock separations creates a very asymmetric Mach disk flow. With the cooled nozzle, the more symmetric restricted-shock separation persisted throughout the start-up transient after the transition, leading to an overall lower side load than that of the adiabatic nozzle. The tepee structures corresponding to the maximum side load were addressed.

  14. Three dimensional strained semiconductors

    Science.gov (United States)

    Voss, Lars; Conway, Adam; Nikolic, Rebecca J.; Leao, Cedric Rocha; Shao, Qinghui

    2016-11-08

    In one embodiment, an apparatus includes a three dimensional structure comprising a semiconductor material, and at least one thin film in contact with at least one exterior surface of the three dimensional structure for inducing a strain in the structure, the thin film being characterized as providing at least one of: an induced strain of at least 0.05%, and an induced strain in at least 5% of a volume of the three dimensional structure. In another embodiment, a method includes forming a three dimensional structure comprising a semiconductor material, and depositing at least one thin film on at least one surface of the three dimensional structure for inducing a strain in the structure, the thin film being characterized as providing at least one of: an induced strain of at least 0.05%, and an induced strain in at least 5% of a volume of the structure.

  15. Color-coded volume rendering for three-dimensional reconstructions of CT data

    International Nuclear Information System (INIS)

    Rieker, O.; Mildenberger, P.; Thelen, M.

    1999-01-01

    Purpose: To evaluate a technique of colored three-dimensional reconstructions without segmentation. Material and methods: Color-coded volume rendered images were reconstructed from the volume data of 25 thoracic, abdominal, musculoskeletal, and vascular helical CT scans using commercial software. The CT volume rendered voxels were encoded with color in the following manner. Opacity, hue, lightness, and chroma were assigned to each of four classes defined by CT number. Color-coded reconstructions were compared to the corresponding grey-scale coded reconstructions. Results: Color-coded volume rendering enabled realistic visualization of pathologic findings when there was sufficient difference in CT density. Segmentation was necessary in some cases to demonstrate small details in a complex volume. Conclusion: Color-coded volume rendering allowed lifelike visualisation of CT volumes without the need of segmentation in most cases. (orig.) [de

  16. Three-dimensional transient electromagnetic modeling in the Laplace Domain

    International Nuclear Information System (INIS)

    Mizunaga, H.; Lee, Ki Ha; Kim, H.J.

    1998-01-01

    In modeling electromagnetic responses, Maxwell's equations in the frequency domain are popular and have been widely used (Nabighian, 1994; Newman and Alumbaugh, 1995; Smith, 1996, to list a few). Recently, electromagnetic modeling in the time domain using the finite difference (FDTD) method (Wang and Hohmann, 1993) has also been used to study transient electromagnetic interactions in the conductive medium. This paper presents a new technique to compute the electromagnetic response of three-dimensional (3-D) structures. The proposed new method is based on transforming Maxwell's equations to the Laplace domain. For each discrete Laplace variable, Maxwell's equations are discretized in 3-D using the staggered grid and the finite difference method (FDM). The resulting system of equations is then solved for the fields using the incomplete Cholesky conjugate gradient (ICCG) method. The new method is particularly effective in saving computer memory since all the operations are carried out in real numbers. For the same reason, the computing speed is faster than frequency domain modeling. The proposed approach can be an extremely useful tool in developing an inversion algorithm using the time domain data

  17. Three-dimensional reconstruction volume: a novel method for volume measurement in kidney cancer.

    Science.gov (United States)

    Durso, Timothy A; Carnell, Jonathan; Turk, Thomas T; Gupta, Gopal N

    2014-06-01

    The role of volumetric estimation is becoming increasingly important in the staging, management, and prognostication of benign and cancerous conditions of the kidney. We evaluated the use of three-dimensional reconstruction volume (3DV) in determining renal parenchymal volumes (RPV) and renal tumor volumes (RTV). We compared 3DV with the currently available methods of volume assessment and determined its interuser reliability. RPV and RTV were assessed in 28 patients who underwent robot-assisted laparoscopic partial nephrectomy for kidney cancer. Patients with a preoperative creatinine level of kidney pre- and postsurgery overestimated 3D reconstruction volumes by 15% to 102% and 12% to 101%, respectively. In addition, volumes obtained from 3DV displayed high interuser reliability regardless of experience. 3DV provides a highly reliable way of assessing kidney volumes. Given that 3DV takes into account visible anatomy, the differences observed using previously published methods can be attributed to the failure of geometry to accurately approximate kidney or tumor shape. 3DV provides a more accurate, reproducible, and clinically useful tool for urologists looking to improve patient care using analysis related to volume.

  18. Three-Dimensional Printed Poly(vinyl alcohol) Substrate with Controlled On-Demand Degradation for Transient Electronics.

    Science.gov (United States)

    Yoon, Jinsu; Han, Jungmin; Choi, Bongsik; Lee, Yongwoo; Kim, Yeamin; Park, Jinhee; Lim, Meehyun; Kang, Min-Ho; Kim, Dae Hwan; Kim, Dong Myong; Kim, Sungho; Choi, Sung-Jin

    2018-05-25

    Electronics that degrade after stable operation for a desired operating time, called transient electronics, are of great interest in many fields, including biomedical implants, secure memory devices, and environmental sensors. Thus, the development of transient materials is critical for the advancement of transient electronics and their applications. However, previous reports have mostly relied on achieving transience in aqueous solutions, where the transience time is largely predetermined based on the materials initially selected at the beginning of the fabrication. Therefore, accurate control of the transience time is difficult, thereby limiting their application. In this work, we demonstrate transient electronics based on a water-soluble poly(vinyl alcohol) (PVA) substrate on which carbon nanotube (CNT)-based field-effect transistors were fabricated. We regulated the structural parameters of the PVA substrate using a three-dimensional (3D) printer to accurately control and program the transience time of the PVA substrate in water. The 3D printing technology can produce complex objects directly, thus enabling the efficient fabrication of a transient substrate with a prescribed and controlled transience time. In addition, the 3D printer was used to develop a facile method for the selective and partial destruction of electronics.

  19. Three dimensional numerical simulation of a full scale CANDU reactor moderator to study temperature fluctuations

    International Nuclear Information System (INIS)

    Sarchami, Araz; Ashgriz, Nasser; Kwee, Marc

    2014-01-01

    Highlights: • 3D model of a Candu reactor is modeled to investigate flow distribution. • The results show the temperature distribution is not symmetrical. • Temperature contours show the hot regions at the top left-hand side of the tank. • Interactions of momentum flows and buoyancy flows create circulation zones. • The results indicate that the moderator tank operates in the buoyancy driven mode. -- Abstract: Three dimensional numerical simulations are conducted on a full scale CANDU Moderator and transient variations of the temperature and velocity distributions inside the tank are determined. The results show that the flow and temperature distributions inside the moderator tank are three dimensional and no symmetry plane can be identified. Competition between the upward moving buoyancy driven flows and the downward moving momentum driven flows in the center region of the tank, results in the formation of circulation zones. The moderator tank operates in the buoyancy driven mode and any small disturbances in the flow or temperature makes the system unstable and asymmetric. Different types of temperature fluctuations are noted inside the tank: (i) large amplitude are at the boundaries between the hot and cold; (ii) low amplitude are in the core of the tank; (iii) high frequency fluctuations are in the regions with high velocities and (iv) low frequency fluctuations are in the regions with lower velocities

  20. Three-dimensional biomedical imaging

    International Nuclear Information System (INIS)

    Robb, R.A.

    1985-01-01

    Scientists in biomedical imaging provide researchers, physicians, and academicians with an understanding of the fundamental theories and practical applications of three-dimensional biomedical imaging methodologies. Succinct descriptions of each imaging modality are supported by numerous diagrams and illustrations which clarify important concepts and demonstrate system performance in a variety of applications. Comparison of the different functional attributes, relative advantages and limitations, complementary capabilities, and future directions of three-dimensional biomedical imaging modalities are given. Volume 1: Introductions to Three-Dimensional Biomedical Imaging Photoelectronic-Digital Imaging for Diagnostic Radiology. X-Ray Computed Tomography - Basic Principles. X-Ray Computed Tomography - Implementation and Applications. X-Ray Computed Tomography: Advanced Systems and Applications in Biomedical Research and Diagnosis. Volume II: Single Photon Emission Computed Tomography. Position Emission Tomography (PET). Computerized Ultrasound Tomography. Fundamentals of NMR Imaging. Display of Multi-Dimensional Biomedical Image Information. Summary and Prognostications

  1. Brain volume measurement using three-dimensional magnetic resonance images

    International Nuclear Information System (INIS)

    Ishimaru, Yoshihiro

    1996-01-01

    This study was designed to validate accurate measurement method of human brain volume using three dimensional (3D) MRI data on a workstation, and to establish optimal correcting method of human brain volume on diagnosis of brain atrophy. 3D MRI data were acquired by fast SPGR sequence using 1.5 T MR imager. 3D MRI data were segmented by region growing method and 3D image was displayed by surface rendering method on the workstation. Brain volume was measured by the volume measurement function of the workstation. In order to validate the accurate measurement method, phantoms and a specimen of human brain were examined. Phantom volume was measured by changing the lower level of threshold value. At the appropriate threshold value, percentage of error of phantoms and the specimen were within 0.6% and 0.08%, respectively. To establish the optimal correcting method, 130 normal volunteers were examined. Brain volumes corrected with height weight, body surface area, and alternative skull volume were evaluated. Brain volume index, which is defined as dividing brain volume by alternative skull volume, had the best correlation with age (r=0.624, p<0.05). No gender differences was observed in brain volume index in contrast to in brain volume. The clinical usefulness of this correcting method for brain atrophy diagnosis was evaluated in 85 patients. Diagnosis by 2D spin echo MR images was compared with brain volume index. Diagnosis of brain atrophy by 2D MR image was concordant with the evaluation by brain volume index. These results indicated that this measurement method had high accuracy, and it was important to set the appropriate threshold value. Brain volume index was the appropriate indication for evaluation of human brain volume, and was considered to be useful for the diagnosis of brain atrophy. (author)

  2. Code Coupling for Multi-Dimensional Core Transient Analysis

    International Nuclear Information System (INIS)

    Park, Jin-Woo; Park, Guen-Tae; Park, Min-Ho; Ryu, Seok-Hee; Um, Kil-Sup; Lee Jae-Il

    2015-01-01

    After the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the Doppler effect becomes important and turns the reactivity balance and power down to lower levels. Although this happens in a very short period of time, only few seconds, the energy generated can be very significant and cause fuel failures. The current safety analysis methodology which is based on overly conservative assumptions with the point kinetics model results in quite adverse consequences. Thus, KEPCO Nuclear Fuel(KNF) is developing the multi-dimensional safety analysis methodology to mitigate the consequences of the single CEA ejection accident. For this purpose, three-dimensional core neutron kinetics code ASTRA, sub-channel analysis code THALES, and fuel performance analysis code FROST, which have transient calculation performance, were coupled using message passing interface (MPI). This paper presents the methodology used for code coupling and the preliminary simulation results with the coupled code system (CHASER). Multi-dimensional core transient analysis code system, CHASER, has been developed and it was applied to simulate a single CEA ejection accident. CHASER gave a good prediction of multi-dimensional core transient behaviors during transient. In the near future, the multi-dimension CEA ejection analysis methodology using CHASER is planning to be developed. CHASER is expected to be a useful tool to gain safety margin for reactivity initiated accidents (RIAs), such as a single CEA ejection accident

  3. Code Coupling for Multi-Dimensional Core Transient Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin-Woo; Park, Guen-Tae; Park, Min-Ho; Ryu, Seok-Hee; Um, Kil-Sup; Lee Jae-Il [KEPCO NF, Daejeon (Korea, Republic of)

    2015-05-15

    After the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the Doppler effect becomes important and turns the reactivity balance and power down to lower levels. Although this happens in a very short period of time, only few seconds, the energy generated can be very significant and cause fuel failures. The current safety analysis methodology which is based on overly conservative assumptions with the point kinetics model results in quite adverse consequences. Thus, KEPCO Nuclear Fuel(KNF) is developing the multi-dimensional safety analysis methodology to mitigate the consequences of the single CEA ejection accident. For this purpose, three-dimensional core neutron kinetics code ASTRA, sub-channel analysis code THALES, and fuel performance analysis code FROST, which have transient calculation performance, were coupled using message passing interface (MPI). This paper presents the methodology used for code coupling and the preliminary simulation results with the coupled code system (CHASER). Multi-dimensional core transient analysis code system, CHASER, has been developed and it was applied to simulate a single CEA ejection accident. CHASER gave a good prediction of multi-dimensional core transient behaviors during transient. In the near future, the multi-dimension CEA ejection analysis methodology using CHASER is planning to be developed. CHASER is expected to be a useful tool to gain safety margin for reactivity initiated accidents (RIAs), such as a single CEA ejection accident.

  4. Fast multiview three-dimensional reconstruction method using cost volume filtering

    Science.gov (United States)

    Lee, Seung Joo; Park, Min Ki; Jang, In Yeop; Lee, Kwan H.

    2014-03-01

    As the number of customers who want to record three-dimensional (3-D) information using a mobile electronic device increases, it becomes more and more important to develop a method which quickly reconstructs a 3-D model from multiview images. A fast multiview-based 3-D reconstruction method is presented, which is suitable for the mobile environment by constructing a cost volume of the 3-D height field. This method consists of two steps: the construction of a reliable base surface and the recovery of shape details. In each step, the cost volume is constructed using photoconsistency and then it is filtered according to the multiscale. The multiscale-based cost volume filtering allows the 3-D reconstruction to maintain the overall shape and to preserve the shape details. We demonstrate the strength of the proposed method in terms of computation time, accuracy, and unconstrained acquisition environment.

  5. Three-dimensional sonographic measurement of normal fetal brain volume during the second half of pregnancy

    NARCIS (Netherlands)

    N.M. Roelfsema; W.C.J. Hop (Wim); S.M. Boito; J.W. Wladimiroff (Juriy)

    2004-01-01

    textabstractObjectives: This study was undertaken to develop a three-dimensional (3D) ultrasound method of measuring fetal brain volume. Study design: Serial 3D sonographic measurements of fetal brain volume were made in 68 normal singleton pregnancies at 18 to 34 weeks of gestation. A comparison

  6. Transient Three-Dimensional Analysis of Nozzle Side Load in Regeneratively Cooled Engines

    Science.gov (United States)

    Wang, Ten-See

    2005-01-01

    Three-dimensional numerical investigations on the start-up side load physics for a regeneratively cooled, high-aspect-ratio nozzle were performed. The objectives of this study are to identify the three-dimensional side load physics and to compute the associated aerodynamic side load using an anchored computational methodology. The computational methodology is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, and a transient inlet condition based on an engine system simulation. Computations were performed for both the adiabatic and cooled walls in order to understand the effect of boundary conditions. Finite-rate chemistry was used throughout the study so that combustion effect is always included. The results show that three types of shock evolution are responsible for side loads: generation of combustion wave; transitions among free-shock separation, restricted-shock separation, and simultaneous free-shock and restricted shock separations; along with oscillation of shocks across the lip. Wall boundary conditions drastically affect the computed side load physics: the adiabatic nozzle prefers free-shock separation while the cooled nozzle favors restricted-shock separation, resulting in higher peak side load for the cooled nozzle than that of the adiabatic nozzle. By comparing the computed physics with those of test observations, it is concluded that cooled wall is a more realistic boundary condition, and the oscillation of the restricted-shock separation flow pattern across the lip along with its associated tangential shock motion are the dominant side load physics for a regeneratively cooled, high aspect-ratio rocket engine.

  7. Visual Interpretation with Three-Dimensional Annotations (VITA): Three-Dimensional Image Interpretation Tool for Radiological Reporting

    OpenAIRE

    Roy, Sharmili; Brown, Michael S.; Shih, George L.

    2013-01-01

    This paper introduces a software framework called Visual Interpretation with Three-Dimensional Annotations (VITA) that is able to automatically generate three-dimensional (3D) visual summaries based on radiological annotations made during routine exam reporting. VITA summaries are in the form of rotating 3D volumes where radiological annotations are highlighted to place important clinical observations into a 3D context. The rendered volume is produced as a Digital Imaging and Communications i...

  8. Three-dimensional volume rendering of tibiofibular joint space and quantitative analysis of change in volume due to tibiofibular syndesmosis diastases

    International Nuclear Information System (INIS)

    Taser, F.; Shafiq, Q.; Ebraheim, N.A.

    2006-01-01

    The diagnosis of ankle syndesmosis injuries is made by various imaging techniques. The present study was undertaken to examine whether the three-dimensional reconstruction of axial CT images and calculation of the volume of tibiofibular joint space enhances the sensitivity of diastases diagnoses or not. Six adult cadaveric ankle specimens were used for spiral CT-scan assessment of tibiofibular syndesmosis. After the specimens were dissected, external fixation was performed and diastases of 1, 2, and 3 mm was simulated by a precalibrated device. Helical CT scans were obtained with 1.0-mm slice thickness. The data was transferred to the computer software AcquariusNET. Then the contours of the tibiofibular syndesmosis joint space were outlined on each axial CT slice and the collection of these slices were stacked using the computer software AutoCAD 2005, according to the spatial arrangement and geometrical coordinates between each slice, to produce a three-dimensional reconstruction of the joint space. The area of each slice and the volume of the entire tibiofibular joint space were calculated. The tibiofibular joint space at the 10th-mm slice level was also measured on axial CT scan images at normal, 1, 2 and 3-mm joint space diastases. The three-dimensional volume-rendering of the tibiofibular syndesmosis joint space from the spiral CT data demonstrated the shape of the joint space and has been found to be a sensitive method for calculating joint space volume. We found that, from normal to 1 mm, a 1-mm diastasis increases approximately 43% of the joint space volume, while from 1 to 3 mm, there is about a 20% increase for each 1-mm increase. Volume calculation using this method can be performed in cases of syndesmotic instability after ankle injuries and for preoperative and postoperative evaluation of the integrity of the tibiofibular syndesmosis. (orig.)

  9. High-resolution three-dimensional imaging of a depleted CMOS sensor using an edge Transient Current Technique based on the Two Photon Absorption process (TPA-eTCT)

    CERN Document Server

    García, Marcos Fernández; Echeverría, Richard Jaramillo; Moll, Michael; Santos, Raúl Montero; Moya, David; Pinto, Rogelio Palomo; Vila, Iván

    2016-01-01

    For the first time, the deep n-well (DNW) depletion space of a High Voltage CMOS sensor has been characterized using a Transient Current Technique based on the simultaneous absorption of two photons. This novel approach has allowed to resolve the DNW implant boundaries and therefore to accurately determine the real depleted volume and the effective doping concentration of the substrate. The unprecedented spatial resolution of this new method comes from the fact that measurable free carrier generation in two photon mode only occurs in a micrometric scale voxel around the focus of the beam. Real three-dimensional spatial resolution is achieved by scanning the beam focus within the sample.

  10. High-resolution three-dimensional imaging of a depleted CMOS sensor using an edge Transient Current Technique based on the Two Photon Absorption process (TPA-eTCT)

    Energy Technology Data Exchange (ETDEWEB)

    García, Marcos Fernández; Sánchez, Javier González; Echeverría, Richard Jaramillo [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain); Moll, Michael [CERN, Organisation europénne pour la recherche nucléaire, CH-1211 Genéve 23 (Switzerland); Santos, Raúl Montero [SGIker Laser Facility, UPV/EHU, Sarriena, s/n - 48940 Leioa-Bizkaia (Spain); Moya, David [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain); Pinto, Rogelio Palomo [Departamento de Ingeniería Electrónica, Escuela Superior de Ingenieros Universidad de Sevilla (Spain); Vila, Iván [Instituto de Física de Cantabria (CSIC-UC), Avda. los Castros s/n, E-39005 Santander (Spain)

    2017-02-11

    For the first time, the deep n-well (DNW) depletion space of a High Voltage CMOS sensor has been characterized using a Transient Current Technique based on the simultaneous absorption of two photons. This novel approach has allowed to resolve the DNW implant boundaries and therefore to accurately determine the real depleted volume and the effective doping concentration of the substrate. The unprecedented spatial resolution of this new method comes from the fact that measurable free carrier generation in two photon mode only occurs in a micrometric scale voxel around the focus of the beam. Real three-dimensional spatial resolution is achieved by scanning the beam focus within the sample.

  11. ADREA-I: A transient three dimensional transport code for atmospheric and other applications - some preliminary results

    International Nuclear Information System (INIS)

    Bartzis, G.

    1985-02-01

    In this work a general description of the ADREA-I code is presented and some preliminary results are discussed. The ADREA-I is a transient three dimensional computer code aimed at transport analysis with particular emphasis on atmospheric dispersion under any realistic terrain conditions (complex or not) applicable to the planetary boundary layer in a distance extending up to a hundred kilometers or more. The complex geometry applications and the reasonable results obtained constitute a solid indication of the broad capability of the code. (author)

  12. Three-dimensional segmentation of pulmonary artery volume from thoracic computed tomography imaging

    Science.gov (United States)

    Lindenmaier, Tamas J.; Sheikh, Khadija; Bluemke, Emma; Gyacskov, Igor; Mura, Marco; Licskai, Christopher; Mielniczuk, Lisa; Fenster, Aaron; Cunningham, Ian A.; Parraga, Grace

    2015-03-01

    Chronic obstructive pulmonary disease (COPD), is a major contributor to hospitalization and healthcare costs in North America. While the hallmark of COPD is airflow limitation, it is also associated with abnormalities of the cardiovascular system. Enlargement of the pulmonary artery (PA) is a morphological marker of pulmonary hypertension, and was previously shown to predict acute exacerbations using a one-dimensional diameter measurement of the main PA. We hypothesized that a three-dimensional (3D) quantification of PA size would be more sensitive than 1D methods and encompass morphological changes along the entire central pulmonary artery. Hence, we developed a 3D measurement of the main (MPA), left (LPA) and right (RPA) pulmonary arteries as well as total PA volume (TPAV) from thoracic CT images. This approach incorporates segmentation of pulmonary vessels in cross-section for the MPA, LPA and RPA to provide an estimate of their volumes. Three observers performed five repeated measurements for 15 ex-smokers with ≥10 pack-years, and randomly identified from a larger dataset of 199 patients. There was a strong agreement (r2=0.76) for PA volume and PA diameter measurements, which was used as a gold standard. Observer measurements were strongly correlated and coefficients of variation for observer 1 (MPA:2%, LPA:3%, RPA:2%, TPA:2%) were not significantly different from observer 2 and 3 results. In conclusion, we generated manual 3D pulmonary artery volume measurements from thoracic CT images that can be performed with high reproducibility. Future work will involve automation for implementation in clinical workflows.

  13. Application status of three-dimensional CT reconstruction in hepatobiliary surgery

    Directory of Open Access Journals (Sweden)

    JIANG Chao

    2017-02-01

    Full Text Available With the development of imaging technology, three-dimensional CT reconstruction has been widely used in hepatobiliary surgery. Three-dimensional CT reconstruction can divide and reconstruct two-dimensional images into three-dimensional images and clearly show the location of lesion and its relationship with the intrahepatic bile duct system. It has an important value in the preoperative assessment of liver volume, diagnosis and treatment decision-making process, intraoperative precise operation, and postoperative individualized management, and promotes the constant development of hepatobiliary surgery and minimally invasive technology, and therefore, it holds promise for clinical application.

  14. User's guide to HEATRAN: a computer program for three-dimensional transient fluid-flow and heat-transfer analysis

    International Nuclear Information System (INIS)

    Wong, C.N.C.; Cheng, S.K.; Todreas, N.E.

    1982-01-01

    This report provides the HEATRAN user with programming and input information. HEATRAN is a computer program which is written to analyze the transient three dimensional single phase incompressible fluid flow and heat transfer problem. In this report, the programming information is given first. This information includes details concerning the code and structure. The description of the required input variables is presented next. Following the input description, the sample problems are described and HEATRAN's results are presented

  15. Three-dimensional two-fluid numerical treatment of a reactor vessel in TRAC

    International Nuclear Information System (INIS)

    Liles, D.R.

    1979-01-01

    A three-dimensional two-fluid finite difference model has been used in TRAC (Transient Reactor Analysis Code) to represent a pressurized water reactor vessel. Mesh cells may be blocked off completely to represent large flow obstructions such as downcomer walls. The hydrodynamic volumes and flow areas may also be reduced in order to provide a porous matrix simulation of smaller scale strucuture. The finite difference equations are semi-implicit so that stability time scales are associated with material movement and not wave propagation. The block matrix structure is reduced during the implicit pass to a single element seven stripe system which is easily solved iteratively. This procedure has successfully performed numerous simulations of both full sized reactor accidents and smaller scale experments. It has proven to be a useful feature of the TRAC effort

  16. Transient three-phase three-component flow. Pt. 3

    International Nuclear Information System (INIS)

    Kolev, N.I.

    1986-05-01

    A mathematical model of a transient three-dimensional three-phase three-component flow described by three-velocity fields in porous body is presented. A combination of separated mass and energy equations together with mixture momentum equations for the flow is used. The mixture equations are used in diffusion form with the assumption that the diffusion velocity can be calculated from empirical correlations. An analytical coupling between the governing equations is developed for calculation of the pressure field. The system is discretized semiimplicitly in 3D-cylindrical space and different solution methods for the algebraic problem are presented. Finally, numerical examples and comparisons with experimental data demonstrate that the method presented is a powerful tool for numerical multiphase flow simulation. (orig.) [de

  17. A transient, Hex-Z nodal code corrected by discontinuity factors

    International Nuclear Information System (INIS)

    Shatilla, Y.A.M.; Henry, A.F.

    1993-01-01

    This document constitutes Volume 1 of the Final Report of a three-year study supported by the special Research Grant Program for Nuclear Energy Research set up by the US Department of Energy. The original motivation for the work was to provide a fast and accurate computer program for the analysis of transients in heavy water or graphite-moderated reactors being considered as candidates for the New Production Reactor. Thus, part of the funding was by way of pass-through money from the Savannah River Laboratory. With this intent in mind, a three-dimensional (Hex-Z), general-energy-group transient, nodal code was created, programmed, and tested. In order to improve accuracy, correction terms, called open-quotes discontinuity factors,close quotes were incorporated into the nodal equations. Ideal values of these factors force the nodal equations to provide node-integrated reaction rates and leakage rates across nodal surfaces that match exactly those edited from a more exact reference calculation. Since the exact reference solution is needed to compute the ideal discontinuity factors, the fact that they result in exact nodal equations would be of little practical interest were it not that approximate discontinuity factors, found at a greatly reduced cost, often yield very accurate results. For example, for light-water reactors, discontinuity factors found from two-dimensional, fine-mesh, multigroup transport solutions for two-dimensional cuts of a fuel assembly provide very accurate predictions of three-dimensional, full-core power distributions. The present document (volume 1) deals primarily with the specification, programming and testing of the three-dimensional, Hex-Z computer program. The program solves both the static (eigenvalue) and transient, general-energy-group, nodal equations corrected by user-supplied discontinuity factors

  18. RAMONA-4B a computer code with three-dimensional neutron kinetics for BWR and SBWR system transient - user's manual

    International Nuclear Information System (INIS)

    Rohatgi, U.S.; Cheng, H.S.; Khan, H.J.; Mallen, A.N.; Neymotin, L.Y.

    1998-03-01

    This document is the User's Manual for the Boiling Water Reactor (BWR), and Simplified Boiling Water Reactor (SBWR) systems transient code RAMONA-4B. The code uses a three-dimensional neutron-kinetics model coupled with a multichannel, nonequilibrium, drift-flux, phase-flow model of the thermal hydraulics of the reactor vessel. The code is designed to analyze a wide spectrum of BWR core and system transients. Chapter 1 gives an overview of the code's capabilities and limitations; Chapter 2 describes the code's structure, lists major subroutines, and discusses the computer requirements. Chapter 3 is on code, auxillary codes, and instructions for running RAMONA-4B on Sun SPARC and IBM Workstations. Chapter 4 contains component descriptions and detailed card-by-card input instructions. Chapter 5 provides samples of the tabulated output for the steady-state and transient calculations and discusses the plotting procedures for the steady-state and transient calculations. Three appendices contain important user and programmer information: lists of plot variables (Appendix A) listings of input deck for sample problem (Appendix B), and a description of the plotting program PAD (Appendix C). 24 refs., 18 figs., 11 tabs

  19. Three dimensional illustrating - three-dimensional vision and deception of sensibility

    Directory of Open Access Journals (Sweden)

    Anita Gánóczy

    2009-03-01

    Full Text Available The wide-spread digital photography and computer use gave the opportunity for everyone to make three-dimensional pictures and to make them public. The new opportunities with three-dimensional techniques give chance for the birth of new artistic photographs. We present in detail the biological roots of three-dimensional visualization, the phenomena of movement parallax, which can be used efficiently in making three-dimensional graphics, the Zöllner- and Corridor-illusion. There are present in this paper the visual elements, which contribute to define a plane two-dimensional image in three-dimension: coherent lines, the covering, the measurement changes, the relative altitude state, the abatement of detail profusion, the shadings and the perspective effects of colors.

  20. Clinical application of three-dimensional spiral CT cerebral angiography with volume rendering

    International Nuclear Information System (INIS)

    Duan Shaoyin; Huang Xi'en; Kang Jianghe; Zhang Dantong; Lin Qingchi; Cai Guoxiang; Xu Meixin; Pang Ruilin

    2002-01-01

    Objective: To study the methodology and assess the clinical value of three-dimensional CT angiography (3D-CTA) with volume rendering (VR) in cerebral vessels. Methods: Sixty-two patients were examined by means of 3D-CTA with volume rendering. VR was used in the reconstruction of 3D images, and the demonstration of normal vessels and vascular lesions were particularly analyzed. At the same time, comparisons were made between the images of VR and SSD, MIP, and also between the diagnosis of VR-CTA and DSA or postoperative results. Results: In VR images, cerebral vessel routes and vessel cavities were showed clearly, while the relationship among vascular lesions, surrounding vessels, and neighboring structure was distinguished. 50 cases (80.6%) were found positive, 48 of which were correct and 2 were false-positive compared with DSA or postoperative results. The accurate rate of diagnosis was 96.0%. There was no obvious difference in showing the cerebral vessel among the images of VR, SSD and MIP (P > 0.25). Conclusion: Three-dimensional CT cerebral angiography with VR is a new noninvasive effective method. It can even partly replace the DSA. The 3D-images have the characteristics of showing the cerebral vascular cavity and overlapped vessels without cutting the skull

  1. Volume-editing tools for three-dimensional imaging of CT data

    International Nuclear Information System (INIS)

    Ney, D.R.; Fishman, E.K.

    1989-01-01

    Three-dimensional imaging of complex structures relies heavily on the ability to edit the routine CT scans to provide an optimal view of the area in question. The authors present a series of strategies for defining the volume editing tools. The authors have developed a series of editing tools that allow the operator to edit critical areas out of an image. The tools are based on a variety of imaging strategies that are implemented depending on the difficulty of separating two structures. The tools combine rectangular masking, threshold base filling, arbitrary curve-based masking, masking, threshold base filling, arbitrary curve-based masking, and object definition via edge detection

  2. Volume rendering based on magnetic resonance imaging: advances in understanding the three-dimensional anatomy of the human knee

    Science.gov (United States)

    Anastasi, Giuseppe; Bramanti, Placido; Di Bella, Paolo; Favaloro, Angelo; Trimarchi, Fabio; Magaudda, Ludovico; Gaeta, Michele; Scribano, Emanuele; Bruschetta, Daniele; Milardi, Demetrio

    2007-01-01

    The choice of medical imaging techniques, for the purpose of the present work aimed at studying the anatomy of the knee, derives from the increasing use of images in diagnostics, research and teaching, and the subsequent importance that these methods are gaining within the scientific community. Medical systems using virtual reality techniques also offer a good alternative to traditional methods, and are considered among the most important tools in the areas of research and teaching. In our work we have shown some possible uses of three-dimensional imaging for the study of the morphology of the normal human knee, and its clinical applications. We used the direct volume rendering technique, and created a data set of images and animations to allow us to visualize the single structures of the human knee in three dimensions. Direct volume rendering makes use of specific algorithms to transform conventional two-dimensional magnetic resonance imaging sets of slices into see-through volume data set images. It is a technique which does not require the construction of intermediate geometric representations, and has the advantage of allowing the visualization of a single image of the full data set, using semi-transparent mapping. Digital images of human structures, and in particular of the knee, offer important information about anatomical structures and their relationships, and are of great value in the planning of surgical procedures. On this basis we studied seven volunteers with an average age of 25 years, who underwent magnetic resonance imaging. After elaboration of the data through post-processing, we analysed the structure of the knee in detail. The aim of our investigation was the three-dimensional image, in order to comprehend better the interactions between anatomical structures. We believe that these results, applied to living subjects, widen the frontiers in the areas of teaching, diagnostics, therapy and scientific research. PMID:17645453

  3. RAMONA-4B a computer code with three-dimensional neutron kinetics for BWR and SBWR system transient - user`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Rohatgi, U.S.; Cheng, H.S.; Khan, H.J.; Mallen, A.N.; Neymotin, L.Y.

    1998-03-01

    This document is the User`s Manual for the Boiling Water Reactor (BWR), and Simplified Boiling Water Reactor (SBWR) systems transient code RAMONA-4B. The code uses a three-dimensional neutron-kinetics model coupled with a multichannel, nonequilibrium, drift-flux, phase-flow model of the thermal hydraulics of the reactor vessel. The code is designed to analyze a wide spectrum of BWR core and system transients. Chapter 1 gives an overview of the code`s capabilities and limitations; Chapter 2 describes the code`s structure, lists major subroutines, and discusses the computer requirements. Chapter 3 is on code, auxillary codes, and instructions for running RAMONA-4B on Sun SPARC and IBM Workstations. Chapter 4 contains component descriptions and detailed card-by-card input instructions. Chapter 5 provides samples of the tabulated output for the steady-state and transient calculations and discusses the plotting procedures for the steady-state and transient calculations. Three appendices contain important user and programmer information: lists of plot variables (Appendix A) listings of input deck for sample problem (Appendix B), and a description of the plotting program PAD (Appendix C). 24 refs., 18 figs., 11 tabs.

  4. Three dimensional system integration

    CERN Document Server

    Papanikolaou, Antonis; Radojcic, Riko

    2010-01-01

    Three-dimensional (3D) integrated circuit (IC) stacking is the next big step in electronic system integration. It enables packing more functionality, as well as integration of heterogeneous materials, devices, and signals, in the same space (volume). This results in consumer electronics (e.g., mobile, handheld devices) which can run more powerful applications, such as full-length movies and 3D games, with longer battery life. This technology is so promising that it is expected to be a mainstream technology a few years from now, less than 10-15 years from its original conception. To achieve thi

  5. Customized Computed Tomography-Based Boost Volumes in Breast-Conserving Therapy: Use of Three-Dimensional Histologic Information for Clinical Target Volume Margins

    International Nuclear Information System (INIS)

    Hanbeukers, Bianca; Borger, Jacques; Ende, Piet van den; Ent, Fred van der; Houben, Ruud; Jager, Jos; Keymeulen, Kristien; Murrer, Lars; Sastrowijoto, Suprapto; Vijver, Koen van de; Boersma, Liesbeth

    2009-01-01

    Purpose: To determine the difference in size between computed tomography (CT)-based irradiated boost volumes and simulator-based irradiated volumes in patients treated with breast-conserving therapy and to analyze whether the use of anisotropic three-dimensional clinical target volume (CTV) margins using the histologically determined free resection margins allows for a significant reduction of the CT-based boost volumes. Patients and Methods: The CT data from 49 patients were used to delineate a planning target volume (PTV) with isotropic CTV margins and to delineate a PTV sim that mimicked the PTV as delineated in the era of conventional simulation. For 17 patients, a PTV with anisotropic CTV margins was defined by applying customized three-dimensional CTV margins, according to the free excision margins in six directions. Boost treatment plans consisted of conformal portals for the CT-based PTVs and rectangular fields for the PTV sim . Results: The irradiated volume (volume receiving ≥95% of the prescribed dose [V 95 ]) for the PTV with isotropic CTV margins was 1.6 times greater than that for the PTV sim : 228 cm 3 vs. 147 cm 3 (p 95 was similar to the V 95 for the PTV sim (190 cm 3 vs. 162 cm 3 ; p = NS). The main determinant for the irradiated volume was the size of the excision cavity (p < .001), which was mainly related to the interval between surgery and the planning CT scan (p = .029). Conclusion: CT-based PTVs with isotropic margins for the CTV yield much greater irradiated volumes than fluoroscopically based PTVs. Applying individualized anisotropic CTV margins allowed for a significant reduction of the irradiated boost volume.

  6. Evaluation of the upset risk in CMOS SRAM through full three dimensional simulation

    International Nuclear Information System (INIS)

    Moreau, Y.; Gasiot, J.; Duzellier, S.

    1995-01-01

    Upsets caused by incident heavy ion on CMOS static RAM are studied here. Three dimensional device simulations, based on a description of a full epitaxial CMOS inverter, and experimental results are reported for evaluation of single and multiple bit error risk. The particular influences of hit location and incidence angle are examined

  7. Prognostic value of three-dimensional ultrasound for fetal hydronephrosis

    Science.gov (United States)

    WANG, JUNMEI; YING, WEIWEN; TANG, DAXING; YANG, LIMING; LIU, DONGSHENG; LIU, YUANHUI; PAN, JIAOE; XIE, XING

    2015-01-01

    The present study evaluated the prognostic value of three-dimensional ultrasound for fetal hydronephrosis. Pregnant females with fetal hydronephrosis were enrolled and a novel three-dimensional ultrasound indicator, renal parenchymal volume/kidney volume, was introduced to predict the postnatal prognosis of fetal hydronephrosis in comparison with commonly used ultrasound indicators. All ultrasound indicators of fetal hydronephrosis could predict whether postnatal surgery was required for fetal hydronephrosis; however, the predictive performance of renal parenchymal volume/kidney volume measurements as an individual indicator was the highest. In conclusion, ultrasound is important in predicting whether postnatal surgery is required for fetal hydronephrosis, and the three-dimensional ultrasound indicator renal parenchymal volume/kidney volume has a high predictive performance. Furthermore, the majority of cases of fetal hydronephrosis spontaneously regress subsequent to birth, and the regression time is closely associated with ultrasound indicators. PMID:25667626

  8. An efficicient data structure for three-dimensional vertex based finite volume method

    Science.gov (United States)

    Akkurt, Semih; Sahin, Mehmet

    2017-11-01

    A vertex based three-dimensional finite volume algorithm has been developed using an edge based data structure.The mesh data structure of the given algorithm is similar to ones that exist in the literature. However, the data structures are redesigned and simplied in order to fit requirements of the vertex based finite volume method. In order to increase the cache efficiency, the data access patterns for the vertex based finite volume method are investigated and these datas are packed/allocated in a way that they are close to each other in the memory. The present data structure is not limited with tetrahedrons, arbitrary polyhedrons are also supported in the mesh without putting any additional effort. Furthermore, the present data structure also supports adaptive refinement and coarsening. For the implicit and parallel implementation of the FVM algorithm, PETSc and MPI libraries are employed. The performance and accuracy of the present algorithm are tested for the classical benchmark problems by comparing the CPU time for the open source algorithms.

  9. Assessment of Groundwater Susceptibility to Non-Point Source Contaminants Using Three-Dimensional Transient Indexes.

    Science.gov (United States)

    Zhang, Yong; Weissmann, Gary S; Fogg, Graham E; Lu, Bingqing; Sun, HongGuang; Zheng, Chunmiao

    2018-06-05

    Groundwater susceptibility to non-point source contamination is typically quantified by stable indexes, while groundwater quality evolution (or deterioration globally) can be a long-term process that may last for decades and exhibit strong temporal variations. This study proposes a three-dimensional (3- d ), transient index map built upon physical models to characterize the complete temporal evolution of deep aquifer susceptibility. For illustration purposes, the previous travel time probability density (BTTPD) approach is extended to assess the 3- d deep groundwater susceptibility to non-point source contamination within a sequence stratigraphic framework observed in the Kings River fluvial fan (KRFF) aquifer. The BTTPD, which represents complete age distributions underlying a single groundwater sample in a regional-scale aquifer, is used as a quantitative, transient measure of aquifer susceptibility. The resultant 3- d imaging of susceptibility using the simulated BTTPDs in KRFF reveals the strong influence of regional-scale heterogeneity on susceptibility. The regional-scale incised-valley fill deposits increase the susceptibility of aquifers by enhancing rapid downward solute movement and displaying relatively narrow and young age distributions. In contrast, the regional-scale sequence-boundary paleosols within the open-fan deposits "protect" deep aquifers by slowing downward solute movement and displaying a relatively broad and old age distribution. Further comparison of the simulated susceptibility index maps to known contaminant distributions shows that these maps are generally consistent with the high concentration and quick evolution of 1,2-dibromo-3-chloropropane (DBCP) in groundwater around the incised-valley fill since the 1970s'. This application demonstrates that the BTTPDs can be used as quantitative and transient measures of deep aquifer susceptibility to non-point source contamination.

  10. Three dimensional visualization of medical images

    International Nuclear Information System (INIS)

    Suto, Yasuzo

    1992-01-01

    Three dimensional visualization is a stereoscopic technique that allows the diagnosis and treatment of complicated anatomy site of the bone and organ. In this article, the current status and technical application of three dimensional visualization are introduced with special reference to X-ray CT and MRI. The surface display technique is the most common for three dimensional visualization, consisting of geometric model, voxel element, and stereographic composition techniques. Recent attention has been paid to display method of the content of the subject called as volume rendering, whereby information on the living body is provided accurately. The application of three dimensional visualization is described in terms of diagnostic imaging and surgical simulation. (N.K.)

  11. Three-Dimensional Phase Field Simulations of Hysteresis and Butterfly Loops by the Finite Volume Method

    International Nuclear Information System (INIS)

    Xi Li-Ying; Chen Huan-Ming; Zheng Fu; Gao Hua; Tong Yang; Ma Zhi

    2015-01-01

    Three-dimensional simulations of ferroelectric hysteresis and butterfly loops are carried out based on solving the time dependent Ginzburg–Landau equations using a finite volume method. The influence of externally mechanical loadings with a tensile strain and a compressive strain on the hysteresis and butterfly loops is studied numerically. Different from the traditional finite element and finite difference methods, the finite volume method is applicable to simulate the ferroelectric phase transitions and properties of ferroelectric materials even for more realistic and physical problems. (paper)

  12. Accuracy of renal volume assessment in children by three-dimensional sonography

    International Nuclear Information System (INIS)

    Fritz, G.A.; Riccabona, M.; Bohdal, G.; Quehenberger, F.

    2003-01-01

    Purpose: Prospective evaluation of the accuracy of three-dimensional ultrasound (3DUS) to assess the renal parenchymal volume. Materials and Methods: CT, MRI, 2DUS and 3DUS were used to measure the renal volume in 40 patients (range: neonate to 17 years; mean age: 8.95 years). The 3DUS was determined with a Voluson 730 (Kretztechnik, GE) or an external 3D-system (EchoTech, GE) using electromagnetic positioning sensors attached to conventional 2DUS-equipment. The 2DUS volume was calculated with the ellipsoid equation and the 3DUS volume computed with the system integrated software. For CT and MRI, planimetric analysis was used to determine the renal parenchymal volume, whereby the dilated collecting system of a hydronephrosis was subtracted to obtain the real renal parenchymal volume. The results of 2DUS and 3DUS were compared to the results of CT and MRI, and inter- and intraobserver variabilities were calculated. Results: In 74 of 77 kidneys, the 3DUS study was of diagnostic quality. The accuracy of the 3DUS volumes compared well to the CT and MRI volumes with a mean difference of -1.8 ± 4.6% versus a mean difference of -2.4 ± 15.4% for 2DUS. In normal kidneys, the accuracy was -2.6 ± 4.4% for 3DUS and -3.8 ± 14.7% for 2DUS. In hydronephrosis, the accuracy was +4.0 ± 5.9% and +9.6 ± 21.3%, respectively, indicating that 3DUS is more accurate than 2DUS, particularly in kidneys with a dilated collecting system. Inter- and intraobserver variabilities were ± 7.3% and ± 5.3%. Conclusion: For assessing the renal parenchymal volume in children, 3DUS is feasible and comparable to CT and MRI. (orig.) [de

  13. Three-dimensional spiral CT during arterial portography: comparison of three rendering techniques.

    Science.gov (United States)

    Heath, D G; Soyer, P A; Kuszyk, B S; Bliss, D F; Calhoun, P S; Bluemke, D A; Choti, M A; Fishman, E K

    1995-07-01

    The three most common techniques for three-dimensional reconstruction are surface rendering, maximum-intensity projection (MIP), and volume rendering. Surface-rendering algorithms model objects as collections of geometric primitives that are displayed with surface shading. The MIP algorithm renders an image by selecting the voxel with the maximum intensity signal along a line extended from the viewer's eye through the data volume. Volume-rendering algorithms sum the weighted contributions of all voxels along the line. Each technique has advantages and shortcomings that must be considered during selection of one for a specific clinical problem and during interpretation of the resulting images. With surface rendering, sharp-edged, clear three-dimensional reconstruction can be completed on modest computer systems; however, overlapping structures cannot be visualized and artifacts are a problem. MIP is computationally a fast technique, but it does not allow depiction of overlapping structures, and its images are three-dimensionally ambiguous unless depth cues are provided. Both surface rendering and MIP use less than 10% of the image data. In contrast, volume rendering uses nearly all of the data, allows demonstration of overlapping structures, and engenders few artifacts, but it requires substantially more computer power than the other techniques.

  14. Three-dimensional Imaging, Visualization, and Display

    CERN Document Server

    Javidi, Bahram; Son, Jung-Young

    2009-01-01

    Three-Dimensional Imaging, Visualization, and Display describes recent developments, as well as the prospects and challenges facing 3D imaging, visualization, and display systems and devices. With the rapid advances in electronics, hardware, and software, 3D imaging techniques can now be implemented with commercially available components and can be used for many applications. This volume discusses the state-of-the-art in 3D display and visualization technologies, including binocular, multi-view, holographic, and image reproduction and capture techniques. It also covers 3D optical systems, 3D display instruments, 3D imaging applications, and details several attractive methods for producing 3D moving pictures. This book integrates the background material with new advances and applications in the field, and the available online supplement will include full color videos of 3D display systems. Three-Dimensional Imaging, Visualization, and Display is suitable for electrical engineers, computer scientists, optical e...

  15. Partial molar volume of proteins studied by the three-dimensional reference interaction site model theory.

    Science.gov (United States)

    Imai, Takashi; Kovalenko, Andriy; Hirata, Fumio

    2005-04-14

    The three-dimensional reference interaction site model (3D-RISM) theory is applied to the analysis of hydration effects on the partial molar volume of proteins. For the native structure of some proteins, the partial molar volume is decomposed into geometric and hydration contributions using the 3D-RISM theory combined with the geometric volume calculation. The hydration contributions are correlated with the surface properties of the protein. The thermal volume, which is the volume of voids around the protein induced by the thermal fluctuation of water molecules, is directly proportional to the accessible surface area of the protein. The interaction volume, which is the contribution of electrostatic interactions between the protein and water molecules, is apparently governed by the charged atomic groups on the protein surface. The polar atomic groups do not make any contribution to the interaction volume. The volume differences between low- and high-pressure structures of lysozyme are also analyzed by the present method.

  16. Strategies to evaluate the impact of rectal volume on prostate motion during three-dimensional conformal radiotherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Ana Paula Diniz Fortuna Poli

    2016-02-01

    Full Text Available Abstract Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation ( p = 0.037. A baseline rectal volume superior to 70 cm3 had a significant influence on the prostate motion in the anteroposterior direction ( p = 0.045. Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm3. Therefore, the treatment of patients with a rectal volume > 70 cm3 should be re-planned with appropriate rectal preparation.

  17. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    Directory of Open Access Journals (Sweden)

    Sung-Hye You

    2017-01-01

    Full Text Available Purpose The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL, for measuring the volume of parathyroid glands. Methods Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D and three-dimensional (3D methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. Results The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. Conclusion The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism.

  18. Three-dimensional transient cooling simulations of a portable electronic device using PCM (phase change materials) in multi-fin heat sink

    International Nuclear Information System (INIS)

    Wang, Yi-Hsien; Yang, Yue-Tzu

    2011-01-01

    Transient three-dimensional heat transfer numerical simulations were conducted to investigate a hybrid PCM (phase change materials) based multi-fin heat sink. Numerical computation was conducted with different amounts of fins (0 fin, 3 fins and 6 fins), various heating power level (2 W, 3 W and 4 W), different orientation tests (vertical/horizontal/slanted), and charge and discharge modes. Calculating time step (0.03 s, 0.05 s, and 0.07 s) size was discussed for transient accuracy as well. The theoretical model developed is validated by comparing numerical predictions with the available experimental data in the literature. The results showed that the transient surface temperatures are predicted with a maximum discrepancy within 10.2%. The operation temperature can be controlled well by the attendance of phase change material and the longer melting time can be conducted by using a multi-fin hybrid heat sink respectively. -- Highlights: → Electronic device cooling use phase change materials. → N-eicosane is adapted as phase change materials. → Present surface transient temperatures prediction error is within 10.2%. → Hybrid PCM-heat sink system provides stable operation temperature. → Orientation effects show independent on the phase change performance.

  19. Time-Domain Three Dimensional BE-FE Method for Transient Response of Floating Structures Under Unsteady Loads

    Directory of Open Access Journals (Sweden)

    R. E. S. Ismail

    Full Text Available Abstract This paper presents a direct time-domain three dimensional (3D numerical procedure to simulate the transient response of very large floating structures (VLFS subjected to unsteady external loads as well as moving mass. The proposed procedure employs the Boundary Element and Finite Element methods (FEM-BEM. The floating structure and the surrounding fluid are discretized by 4-node isoparametric finite elements (FE and by 4-node constant boundary elements (BE, respectively. Structural analysis is based on Mindlin's plate theory. The equation of motion is constructed taking into account the effect of inertia loading due to the moving mass. In order to obtain the hydrodynamic forces (added mass and radiation damping, the coupled natural frequencies are first obtained by an iterative method, since hydrodynamic forces become frequency-dependent. Then the Newark integration method is employed to solve the equation of motion for structural system. In order to prove the validity of the present method, a FORTRAN program is developed and numerical examples are carried out to compare its results with those of published experimental results of a scale model of VLFS under a weight drop and airplane landing and takeoff in still water condition. The comparisons show very good agreement.

  20. Measuring stone volume - three-dimensional software reconstruction or an ellipsoid algebra formula?

    Science.gov (United States)

    Finch, William; Johnston, Richard; Shaida, Nadeem; Winterbottom, Andrew; Wiseman, Oliver

    2014-04-01

    To determine the optimal method for assessing stone volume, and thus stone burden, by comparing the accuracy of scalene, oblate, and prolate ellipsoid volume equations with three-dimensional (3D)-reconstructed stone volume. Kidney stone volume may be helpful in predicting treatment outcome for renal stones. While the precise measurement of stone volume by 3D reconstruction can be accomplished using modern computer tomography (CT) scanning software, this technique is not available in all hospitals or with routine acute colic scanning protocols. Therefore, maximum diameters as measured by either X-ray or CT are used in the calculation of stone volume based on a scalene ellipsoid formula, as recommended by the European Association of Urology. In all, 100 stones with both X-ray and CT (1-2-mm slices) were reviewed. Complete and partial staghorn stones were excluded. Stone volume was calculated using software designed to measure tissue density of a certain range within a specified region of interest. Correlation coefficients among all measured outcomes were compared. Stone volumes were analysed to determine the average 'shape' of the stones. The maximum stone diameter on X-ray was 3-25 mm and on CT was 3-36 mm, with a reasonable correlation (r = 0.77). Smaller stones (15 mm towards scalene ellipsoids. There was no difference in stone shape by location within the kidney. As the average shape of renal stones changes with diameter, no single equation for estimating stone volume can be recommended. As the maximum diameter increases, calculated stone volume becomes less accurate, suggesting that larger stones have more asymmetric shapes. We recommend that research looking at stone clearance rates should use 3D-reconstructed stone volumes when available, followed by prolate, oblate, or scalene ellipsoid formulas depending on the maximum stone diameter. © 2013 The Authors. BJU International © 2013 BJU International.

  1. Extending the XFEM approach for fast transient three-dimensional crack propagation in ductile materials

    International Nuclear Information System (INIS)

    Pelee-De-Saint-Maurice, Romains

    2014-01-01

    This PhD thesis presents numerical methods is dedicated to three-dimensional crack propagation in the framework of fast explicit structural dynamics using EUROPLEXUS software (currently abbreviated EPX, co-owned by CEA and EC/JRC). An approach based on the well-known XFEM method is proposed, representing the crack through level set functions. Special care is given to the update of the level set functions from the propagation velocity expressed on the crack edge, since the most widely used method based on the solution of Hamilton-Jacobi equations lacks robustness for fast transient crack propagations, even when level-sets are computed on an auxiliary regular finite difference grid. It is therefore chosen instead to implement a 3D approximated geometric method to update both level-sets. As far as failure mechanics is concerned, a local stress criterion on the edge of the crack, first developed by Haboussa et al., gives characteristic parameters of the material fracture. Mechanical equivalent quantities (strain, deformation) around the crack front are weighted by a Gaussian function, which gives more importance to Gauss integration points located near the crack tip. The maximum of the equivalent stress tensor near the crack tip gives the direction of the crack, and the Kanninen equation gives the crack velocity. Besides, because of the discontinuous displacement field, the numerical integration for elements cut by the crack yields performance issues. Increasing the number of quadrature points is CPU time consuming and quite hard to handle if it is chosen to change the number of points only for elements in the vicinity of the crack. Another approach tested here consists in keeping constant the number and position of quadrature points and modifying their weights in cut elements to obtain an accurate integration of several reference discontinuous fields. The proposed methods are tested and validated on significant examples, both two-dimensional, to ensure the backward

  2. Strategies to evaluate the impact of rectal volume on prostate motion during three-dimensional conformal radiotherapy for prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Poli, Ana Paula Diniz Fortuna, E-mail: anapaulafortuna@yahoo.com.br [Universidade Estadual de Campinas (CAISM/UNICAMP), Campinas, SP (Brazil). Centro de Atencao Integrada a Saude da Mulher. Divisao de Radioterapia; Dias, Rodrigo Souza; Giordani, Adelmo Jose; Segreto, Helena Regina Comodo; Segreto, Roberto Araujo [Universidade Federal de Sao Paulo (EPM/UNIFESP), Sao Paulo, SP (Brazil). Escola Paulista de Medicina. Divisao de Radioterapia

    2016-01-15

    Objective: To evaluate the rectal volume influence on prostate motion during three-dimensional conformal radiotherapy (3D-CRT) for prostate cancer. Materials and Methods: Fifty-one patients with prostate cancer underwent a series of three computed tomography scans including an initial planning scan and two subsequent scans during 3D-CRT. The organs of interest were outlined. The prostate contour was compared with the initial CT images considering the anterior, posterior, superior, inferior and lateral edges of the organ. Variations in the anterior limits and volume of the rectum were assessed and correlated with prostate motion in the anteroposterior direction. Results: The maximum range of prostate motion was observed in the superoinferior direction, followed by the anteroposterior direction. A significant correlation was observed between prostate motion and rectal volume variation (p = 0.037). A baseline rectal volume superior to 70 cm{sup 3} had a significant influence on the prostate motion in the anteroposterior direction (p = 0.045). Conclusion: The present study showed a significant interfraction motion of the prostate during 3D-CRT with greatest variations in the superoinferior and anteroposterior directions, and that a large rectal volume influences the prostate motion with a cutoff value of 70 cm{sup 3}. Therefore, the treatment of patients with a rectal volume > 70 cm{sup 3} should be re-planned with appropriate rectal preparation. Keywords: Rectal volume; Prostate cancer; Three-dimensional conformal radiotherapy. (author)

  3. Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Rijken Marcus J

    2012-01-01

    Full Text Available Abstract Background The presence of malaria parasites and histopathological changes in the placenta are associated with a reduction in birth weight, principally due to intrauterine growth restriction. The aim of this study was to examine the feasibility of studying early pregnancy placental volumes using three-dimensional (3D ultrasound in a malaria endemic area, as a small volume in the second trimester may be an indicator of intra-uterine growth restriction and placental insufficiency. Methods Placenta volumes were acquired using a portable ultrasound machine and a 3D ultrasound transducer and estimated using the Virtual Organ Computer-aided AnaLysis (VOCAL image analysis software package. Intra-observer reliability and limits of agreement of the placenta volume measurements were calculated. Polynomial regression models for the mean and standard deviation as a function of gestational age for the placental volumes of uninfected women were created and tested. Based on these equations each measurement was converted into a z -score. The z-scores of the placental volumes of malaria infected and uninfected women were then compared. Results Eighty-four women (uninfected = 65; infected = 19 with a posterior placenta delivered congenitally normal, live born, single babies. The mean placental volumes in the uninfected women were modeled to fit 5th, 10th, 50th, 90th and 95th centiles for 14-24 weeks' gestation. Most placenta volumes in the infected women were below the 50th centile for gestational age; most of those with Plasmodium falciparum were below the 10th centile. The 95% intra-observer limits of agreement for first and second measurements were ± 37.0 mL and ± 25.4 mL at 30 degrees and 15 degrees rotation respectively. Conclusion The new technique of 3D ultrasound volumetry of the placenta may be useful to improve our understanding of the pathophysiological constraints on foetal growth caused by malaria infection in early pregnancy.

  4. CT liver volumetry using three-dimensional image data in living donor liver transplantation: Effects of slice thickness on volume calculation

    Science.gov (United States)

    Hori, Masatoshi; Suzuki, Kenji; Epstein, Mark L.; Baron, Richard L.

    2011-01-01

    The purpose was to evaluate a relationship between slice thickness and calculated volume on CT liver volumetry by comparing the results for images with various slice thicknesses including three-dimensional images. Twenty adult potential liver donors (12 men, 8 women; mean age, 39 years; range, 24–64) underwent CT with a 64-section multi-detector row CT scanner after intra-venous injection of contrast material. Four image sets with slice thicknesses of 0.625 mm, 2.5 mm, 5 mm, and 10 mm were used. First, a program developed in our laboratory for automated liver extraction was applied to CT images, and the liver boundary was obtained automatically. Then, an abdominal radiologist reviewed all images on which automatically extracted boundaries were superimposed, and edited the boundary on each slice to enhance the accuracy. Liver volumes were determined by counting of the voxels within the liver boundary. Mean whole liver volumes estimated with CT were 1322.5 cm3 on 0.625-mm, 1313.3 cm3 on 2.5-mm, 1310.3 cm3 on 5-mm, and 1268.2 cm3 on 10-mm images. Volumes calculated for three-dimensional (0.625-mm-thick) images were significantly larger than those for thicker images (Pvolumetry. If not, three-dimensional images could be essential. PMID:21850689

  5. Comparative Three-Dimensional Morphology of Baleen: Cross-Sectional Profiles and Volume Measurements Using CT Images.

    Science.gov (United States)

    Jensen, Megan M; Saladrigas, Amalia H; Goldbogen, Jeremy A

    2017-11-01

    Baleen whales are obligate filter feeders, straining prey-laden seawater through racks of keratinized baleen plates. Despite the importance of baleen to the ecology and natural history of these animals, relatively little work has been done on baleen morphology, particularly with regard to the three-dimensional morphology and structure of baleen. We used computed tomography (CT) scanning to take 3D images of six baleen specimens representing five species, including three complete racks. With these images, we described the three-dimensional shape of the baleen plates using cross-sectional profiles from within the gum tissue to the tip of the plates. We also measured the percentage of each specimen that was composed of either keratinized plate material or was void space between baleen plates, and thus available for seawater flow. Baleen plates have a complex three-dimensional structure with curvature that varies across the anterior-posterior, proximal-distal, and medial-lateral (lingual-labial) axes. These curvatures also vary with location along the baleen rack, and between species. Cross-sectional profiles resemble backwards-facing airfoils, and some specimens display S-shaped, or reflexed, camber. Within a baleen specimen, the intra-baleen void volume correlates with the average bristle diameter for a species, suggesting that essentially, thinner plates (with more space between them for flow) have thinner bristles. Both plate curvature and the relative proportions of plate and void volumes are likely to have implications for the mechanics of mysticete filtration, and future studies are needed to determine the particular functions of these morphological characters. Anat Rec, 300:1942-1952, 2017. © 2017 The Authors The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists. © 2017 The Authors The Anatomical Record published by Wiley Periodicals, Inc. on behalf of American Association of Anatomists.

  6. A three-dimensional transient calculation for the reactor model RAMONA using the COMMIX-2(V) code

    International Nuclear Information System (INIS)

    Weinberg, D.; Frey, H.H.; Tschoeke, H.

    1993-01-01

    The safety graded decay heat removal system of the European Fast Reactor needs a high availability. This system operates entirely under natural convection. To guarantee a proper design, experiments are carried out to verify thermal-hydraulic computer codes able to predict precisely local temperature loadings of the components and the reactor tank in the transition region from nominal operation under forced convection to the decay heat removal operation. - With the COMMIX-2 (V) code three-dimensional transient calculations have been performed to simulate experiments in the 360 deg. reactor model RAMONA, scaled 1:20 to the reality with water as simulant fluid for sodium. The computed average and local temperatures as well as the velocity distributions show a good agreement with the experimental results. Further efforts are necessary to reduce the computation time. (orig.)

  7. Renormalization of period doubling in symmetric four-dimensional volume-preserving maps

    International Nuclear Information System (INIS)

    Mao, J.; Greene, J.M.

    1987-01-01

    We have determined three maps (truncated at quadratic terms) that are fixed under the renormalization operator of pitchfork period doubling in symmetric four-dimensional volume-preserving maps. Each of these contains the previously known two-dimensional area-preserving map that is fixed under the period-doubling operator. One of these three fixed maps consists of two uncoupled two-dimensional (nonlinear) area-preserving fixed maps. The other two contain also the two-dimensional area-preserving fixed map coupled (in general) with a linear two-dimensional map. The renormalization calculation recovers all numerical results for the pitchfork period doubling in the symmetric four-dimensional volume-preserving maps, reported by Mao and Helleman [Phys. Rev. A 35, 1847 (1987)]. For a large class of nonsymmetric four-dimensional volume-preserving maps, we found that the fixed maps are the same as those for the symmetric maps

  8. Application of image processing and different types of imaging devices for three-dimensional imaging of coal grains

    OpenAIRE

    Oleszko, K.; Mlynarczuk, M.; Sitek, L. (Libor); Staš, L. (Lubomír)

    2015-01-01

    Precise particle size measurements are important in many aspects of engineering geology, e.g. in mineral processing and the study of methane hazard in coal mines. The volume of grains, estimated exclusively on the basis of dimensions of the grains differs tens of percent from the volume obtained from 3D digital measurements. This confirms that full three-dimensional automatic imaging can be used in the measurements of the particles. The paper discusses the technique of three-dimensional imagi...

  9. Three-dimensional reconstruction of functional brain images

    International Nuclear Information System (INIS)

    Inoue, Masato; Shoji, Kazuhiko; Kojima, Hisayoshi; Hirano, Shigeru; Naito, Yasushi; Honjo, Iwao

    1999-01-01

    We consider PET (positron emission tomography) measurement with SPM (Statistical Parametric Mapping) analysis to be one of the most useful methods to identify activated areas of the brain involved in language processing. SPM is an effective analytical method that detects markedly activated areas over the whole brain. However, with the conventional presentations of these functional brain images, such as horizontal slices, three directional projection, or brain surface coloring, makes understanding and interpreting the positional relationships among various brain areas difficult. Therefore, we developed three-dimensionally reconstructed images from these functional brain images to improve the interpretation. The subjects were 12 normal volunteers. The following three types of images were constructed: routine images by SPM, three-dimensional static images, and three-dimensional dynamic images, after PET images were analyzed by SPM during daily dialog listening. The creation of images of both the three-dimensional static and dynamic types employed the volume rendering method by VTK (The Visualization Toolkit). Since the functional brain images did not include original brain images, we synthesized SPM and MRI brain images by self-made C++ programs. The three-dimensional dynamic images were made by sequencing static images with available software. Images of both the three-dimensional static and dynamic types were processed by a personal computer system. Our newly created images showed clearer positional relationships among activated brain areas compared to the conventional method. To date, functional brain images have been employed in fields such as neurology or neurosurgery, however, these images may be useful even in the field of otorhinolaryngology, to assess hearing and speech. Exact three-dimensional images based on functional brain images are important for exact and intuitive interpretation, and may lead to new developments in brain science. Currently, the surface

  10. Three-dimensional reconstruction of functional brain images

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Masato; Shoji, Kazuhiko; Kojima, Hisayoshi; Hirano, Shigeru; Naito, Yasushi; Honjo, Iwao [Kyoto Univ. (Japan)

    1999-08-01

    We consider PET (positron emission tomography) measurement with SPM (Statistical Parametric Mapping) analysis to be one of the most useful methods to identify activated areas of the brain involved in language processing. SPM is an effective analytical method that detects markedly activated areas over the whole brain. However, with the conventional presentations of these functional brain images, such as horizontal slices, three directional projection, or brain surface coloring, makes understanding and interpreting the positional relationships among various brain areas difficult. Therefore, we developed three-dimensionally reconstructed images from these functional brain images to improve the interpretation. The subjects were 12 normal volunteers. The following three types of images were constructed: routine images by SPM, three-dimensional static images, and three-dimensional dynamic images, after PET images were analyzed by SPM during daily dialog listening. The creation of images of both the three-dimensional static and dynamic types employed the volume rendering method by VTK (The Visualization Toolkit). Since the functional brain images did not include original brain images, we synthesized SPM and MRI brain images by self-made C++ programs. The three-dimensional dynamic images were made by sequencing static images with available software. Images of both the three-dimensional static and dynamic types were processed by a personal computer system. Our newly created images showed clearer positional relationships among activated brain areas compared to the conventional method. To date, functional brain images have been employed in fields such as neurology or neurosurgery, however, these images may be useful even in the field of otorhinolaryngology, to assess hearing and speech. Exact three-dimensional images based on functional brain images are important for exact and intuitive interpretation, and may lead to new developments in brain science. Currently, the surface

  11. Characterization of iron ferromagnetism by the local atomic volume: from three-dimensional structures to isolated atoms.

    Science.gov (United States)

    Zhang, Lei; Sob, M; Wu, Zhe; Zhang, Ying; Lu, Guang-Hong

    2014-02-26

    We present a comprehensive study of the relationship between the ferromagnetism and the structural properties of Fe systems from three-dimensional ones to isolated atoms based on the spin-density functional theory. We have found a relation between the magnetic moment and the volume of the Voronoi polyhedron, determining, in most cases, the value of the total magnetic moment as a function of this volume with an average accuracy of ±0.28 μ(B) and of the 3d magnetic moment with an average accuracy of ±0.07 μ(B) when the atomic volume is larger than 22 ų. It is demonstrated that this approach is applicable for many three-dimensional systems, including high-symmetry structures of perfect body-centered cubic (bcc), face-centered cubic (fcc), hexagonal close-packed (hcp), double hexagonal close-packed (dhcp), and simple cubic (sc) crystals, as well as for lower-symmetry ones, for example atoms near a grain boundary (GB) or a surface, around a vacancy or in a linear chain (for low-dimensional cases, we provide a generalized definition of the Voronoi polyhedron). Also, we extend the validity of the Stoner model to low-dimensional structures, such as atomic chains, free-standing monolayers and surfaces, determining the Stoner parameter for these systems. The ratio of the 3d-exchange splitting to the magnetic moment, corresponding to the Stoner parameter, is found to be I(3d) = (0.998 ± 0.006) eV /μ(B) for magnetic moments up to 3.0 μ(B). Further, the 3d exchange splitting changes nearly linearly in the region of higher magnetic moments (3.0-4.0 μ(B)) and the corresponding Stoner exchange parameter equals I(h)(3d) = (0.272 ± 0.006) eV /μ(B). The existence of these two regions reflects the fact that, with increasing Voronoi volume, the 3d bands separate first and, consequently, the 3d magnetic moment increases. When the Voronoi volume is sufficiently large (≥22 ų), the separation of the 3d bands is complete and the magnetic moment reaches a value of 3.0

  12. Characterization of iron ferromagnetism by the local atomic volume: from three-dimensional structures to isolated atoms

    International Nuclear Information System (INIS)

    Zhang, Lei; Šob, M; Wu, Zhe; Zhang, Ying; Lu, Guang-Hong

    2014-01-01

    We present a comprehensive study of the relationship between the ferromagnetism and the structural properties of Fe systems from three-dimensional ones to isolated atoms based on the spin-density functional theory. We have found a relation between the magnetic moment and the volume of the Voronoi polyhedron, determining, in most cases, the value of the total magnetic moment as a function of this volume with an average accuracy of ±0.28 μ B and of the 3d magnetic moment with an average accuracy of ±0.07 μ B when the atomic volume is larger than 22 Å 3 . It is demonstrated that this approach is applicable for many three-dimensional systems, including high-symmetry structures of perfect body-centered cubic (bcc), face-centered cubic (fcc), hexagonal close-packed (hcp), double hexagonal close-packed (dhcp), and simple cubic (sc) crystals, as well as for lower-symmetry ones, for example atoms near a grain boundary (GB) or a surface, around a vacancy or in a linear chain (for low-dimensional cases, we provide a generalized definition of the Voronoi polyhedron). Also, we extend the validity of the Stoner model to low-dimensional structures, such as atomic chains, free-standing monolayers and surfaces, determining the Stoner parameter for these systems. The ratio of the 3d-exchange splitting to the magnetic moment, corresponding to the Stoner parameter, is found to be I 3d = (0.998 ± 0.006) eV /μ B for magnetic moments up to 3.0 μ B . Further, the 3d exchange splitting changes nearly linearly in the region of higher magnetic moments (3.0–4.0 μ B ) and the corresponding Stoner exchange parameter equals I 3d h =(0.272±0.006) eV/μ B . The existence of these two regions reflects the fact that, with increasing Voronoi volume, the 3d bands separate first and, consequently, the 3d magnetic moment increases. When the Voronoi volume is sufficiently large (≥22 Å 3 ), the separation of the 3d bands is complete and the magnetic moment reaches a value of 3.0

  13. Quantifying and Predicting Three-Dimensional Heterogeneity in Transient Storage Using Roving Profiling

    Science.gov (United States)

    Kaplan, D. A.; Reaver, N.; Hensley, R. T.; Cohen, M. J.

    2017-12-01

    Hydraulic transport is an important component of nutrient spiraling in streams. Quantifying conservative solute transport is a prerequisite for understanding the cycling and fate of reactive solutes, such as nutrients. Numerous studies have modeled solute transport within streams using the one-dimensional advection, dispersion and storage (ADS) equation calibrated to experimental data from tracer experiments. However, there are limitations to the information about in-stream transient storage that can be derived from calibrated ADS model parameters. Transient storage (TS) in the ADS model is most often modeled as a single process, and calibrated model parameters are "lumped" values that are the best-fit representation of multiple real-world TS processes. In this study, we developed a roving profiling method to assess and predict spatial heterogeneity of in-stream TS. We performed five tracer experiments on three spring-fed rivers in Florida (USA) using Rhodamine WT. During each tracer release, stationary fluorometers were deployed to measure breakthrough curves for multiple reaches within the river. Teams of roving samplers moved along the rivers measuring tracer concentrations at various locations and depths within the reaches. A Bayesian statistical method was used to calibrate the ADS model to the stationary breakthrough curves, resulting in probability distributions for both the advective and TS zone as a function of river distance and time. Rover samples were then assigned a probability of being from either the advective or TS zone by comparing measured concentrations to the probability distributions of concentrations in the ADS advective and TS zones. A regression model was used to predict the probability of any in-stream position being located within the advective versus TS zone based on spatiotemporal predictors (time, river position, depth, and distance from bank) and eco-geomorphological feature (eddies, woody debris, benthic depressions, and aquatic

  14. Three-dimensional radiation treatment planning

    International Nuclear Information System (INIS)

    Mohan, R.

    1989-01-01

    A major aim of radiation therapy is to deliver sufficient dose to the tumour volume to kill the cancer cells while sparing the nearby health organs to prevent complications. With the introduction of devices such as CT and MR scanners, radiation therapy treatment planners have access to full three-dimensional anatomical information to define, simulate, and evaluate treatments. There are a limited number of prototype software systems that allow 3D treatment planning currently in use. In addition, there are more advanced tools under development or still in the planning stages. They require sophisticated graphics and computation equipment, complex physical and mathematical algorithms, and new radiation treatment machines that deliver dose very precisely under computer control. Components of these systems include programs for the identification and delineation of the anatomy and tumour, the definition of radiation beams, the calculation of dose distribution patterns, the display of dose on 2D images and as three dimensional surfaces, and the generation of computer images to verify proper patient positioning in treatment. Some of these functions can be performed more quickly and accurately if artificial intelligence or expert systems techniques are employed. 28 refs., figs

  15. Topology as fluid geometry two-dimensional spaces, volume 2

    CERN Document Server

    Cannon, James W

    2017-01-01

    This is the second of a three volume collection devoted to the geometry, topology, and curvature of 2-dimensional spaces. The collection provides a guided tour through a wide range of topics by one of the twentieth century's masters of geometric topology. The books are accessible to college and graduate students and provide perspective and insight to mathematicians at all levels who are interested in geometry and topology. The second volume deals with the topology of 2-dimensional spaces. The attempts encountered in Volume 1 to understand length and area in the plane lead to examples most easily described by the methods of topology (fluid geometry): finite curves of infinite length, 1-dimensional curves of positive area, space-filling curves (Peano curves), 0-dimensional subsets of the plane through which no straight path can pass (Cantor sets), etc. Volume 2 describes such sets. All of the standard topological results about 2-dimensional spaces are then proved, such as the Fundamental Theorem of Algebra (two...

  16. SCORE-EVET: a computer code for the multidimensional transient thermal-hydraulic analysis of nuclear fuel rod arrays

    International Nuclear Information System (INIS)

    Benedetti, R.L.; Lords, L.V.; Kiser, D.M.

    1978-02-01

    The SCORE-EVET code was developed to study multidimensional transient fluid flow in nuclear reactor fuel rod arrays. The conservation equations used were derived by volume averaging the transient compressible three-dimensional local continuum equations in Cartesian coordinates. No assumptions associated with subchannel flow have been incorporated into the derivation of the conservation equations. In addition to the three-dimensional fluid flow equations, the SCORE-EVET code ocntains: (a) a one-dimensional steady state solution scheme to initialize the flow field, (b) steady state and transient fuel rod conduction models, and (c) comprehensive correlation packages to describe fluid-to-fuel rod interfacial energy and momentum exchange. Velocity and pressure boundary conditions can be specified as a function of time and space to model reactor transient conditions such as a hypothesized loss-of-coolant accident (LOCA) or flow blockage

  17. Determination of aerodynamic sensitivity coefficients based on the three-dimensional full potential equation

    Science.gov (United States)

    Elbanna, Hesham M.; Carlson, Leland A.

    1992-01-01

    The quasi-analytical approach is applied to the three-dimensional full potential equation to compute wing aerodynamic sensitivity coefficients in the transonic regime. Symbolic manipulation is used to reduce the effort associated with obtaining the sensitivity equations, and the large sensitivity system is solved using 'state of the art' routines. Results are compared to those obtained by the direct finite difference approach and both methods are evaluated to determine their computational accuracy and efficiency. The quasi-analytical approach is shown to be accurate and efficient for large aerodynamic systems.

  18. MRI definition of target volumes using fuzzy logic method for three-dimensional conformal radiation therapy

    International Nuclear Information System (INIS)

    Caudrelier, Jean-Michel; Vial, Stephane; Gibon, David; Kulik, Carine; Fournier, Charles; Castelain, Bernard; Coche-Dequeant, Bernard; Rousseau, Jean

    2003-01-01

    Purpose: Three-dimensional (3D) volume determination is one of the most important problems in conformal radiation therapy. Techniques of volume determination from tomographic medical imaging are usually based on two-dimensional (2D) contour definition with the result dependent on the segmentation method used, as well as on the user's manual procedure. The goal of this work is to describe and evaluate a new method that reduces the inaccuracies generally observed in the 2D contour definition and 3D volume reconstruction process. Methods and Materials: This new method has been developed by integrating the fuzziness in the 3D volume definition. It first defines semiautomatically a minimal 2D contour on each slice that definitely contains the volume and a maximal 2D contour that definitely does not contain the volume. The fuzziness region in between is processed using possibility functions in possibility theory. A volume of voxels, including the membership degree to the target volume, is then created on each slice axis, taking into account the slice position and slice profile. A resulting fuzzy volume is obtained after data fusion between multiorientation slices. Different studies have been designed to evaluate and compare this new method of target volume reconstruction and a classical reconstruction method. First, target definition accuracy and robustness were studied on phantom targets. Second, intra- and interobserver variations were studied on radiosurgery clinical cases. Results: The absolute volume errors are less than or equal to 1.5% for phantom volumes calculated by the fuzzy logic method, whereas the values obtained with the classical method are much larger than the actual volumes (absolute volume errors up to 72%). With increasing MRI slice thickness (1 mm to 8 mm), the phantom volumes calculated by the classical method are increasing exponentially with a maximum absolute error up to 300%. In contrast, the absolute volume errors are less than 12% for phantom

  19. Four-dimensional anti-de Sitter toroidal black holes from a three-dimensional perspective: Full complexity

    International Nuclear Information System (INIS)

    Zanchin, Vilson T.; Kleber, Antares; Lemos, Jose P.S.

    2002-01-01

    The dimensional reduction of black hole solutions in four-dimensional (4D) general relativity is performed and new 3D black hole solutions are obtained. Considering a 4D spacetime with one spacelike Killing vector, it is possible to split the Einstein-Hilbert-Maxwell action with a cosmological term in terms of 3D quantities. Definitions of quasilocal mass and charges in 3D spacetimes are reviewed. The analysis is then particularized to the toroidal charged rotating anti-de Sitter black hole. The reinterpretation of the fields and charges in terms of a three-dimensional point of view is given in each case, and the causal structure analyzed

  20. Metopic synostosis: Measuring intracranial volume change following fronto-orbital advancement using three-dimensional photogrammetry.

    Science.gov (United States)

    Freudlsperger, Christian; Steinmacher, Sahra; Bächli, Heidi; Somlo, Elek; Hoffmann, Jürgen; Engel, Michael

    2015-06-01

    There is still disagreement regarding the intracranial volumes of patients with metopic synostosis compared with healthy patients. This study aimed to compare the intracranial volume of children with metopic synostosis before and after surgery to an age- and sex-matched control cohort using three-dimensional (3D) photogrammetry. Eighteen boys with metopic synostosis were operated on using standardized fronto-orbital advancement. Frontal, posterior and total intracranial volumes were measured exactly 1 day pre-operatively and 10 days post-operatively, using 3D photogrammetry. To establish an age- and sex-matched control group, the 3D photogrammetric data of 634 healthy boys between the ages of 3 and 13 months were analyzed. Mean age at surgery was 9 months (SD 1.7). Prior to surgery, boys with metopic synostosis showed significantly reduced frontal and total intracranial volumes compared with the reference group, but similar posterior volumes. After surgery, frontal and total intracranial volumes did not differ statistically from the control group. As children with metopic synostosis showed significantly smaller frontal and total intracranial volumes compared with an age- and sex-matched control group, corrective surgery should aim to achieve volume expansion. Furthermore, 3D photogrammetry provides a valuable alternative to CT scans in the measurement of intracranial volume in children with metopic synostosis, which significantly reduces the amount of radiation exposure to the growing brain. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Development and proof-of-concept of three-dimensional lung histology volumes

    Science.gov (United States)

    Mathew, Lindsay; Alabousi, Mostafa; Wheatley, Andrew; Aladl, Usaf; Slipetz, Deborah; Hogg, James C.; Fenster, Aaron; Parraga, Grace

    2012-03-01

    Most medical imaging is inherently three-dimensional (3D) but for validation of pathological findings, histopathology is commonly used and typically histopathology images are acquired as twodimensional slices with quantitative analysis performed in a single dimension. Histopathology is invasive, labour-intensive, and the analysis cannot be performed in real time, yet it remains the gold standard for the pathological diagnosis and validation of clinical or radiological diagnoses of disease. A major goal worldwide is to improve medical imaging resolution, sensitivity and specificity to better guide therapy and biopsy and to one day delay or replace biopsy. A key limitation however is the lack of tools to directly compare 3D macroscopic imaging acquired in patients with histopathology findings, typically provided in a single dimension (1D) or in two dimensions (2D). To directly address this, we developed methods for 2D histology slice visualization/registration to generate 3D volumes and quantified tissue components in the 3D volume for direct comparison to volumetric micro-CT and clinical CT. We used the elastase-instilled mouse emphysema lung model to evaluate our methods with murine lungs sectioned (5 μm thickness/10 μm gap) and digitized with 2μm in-plane resolution. 3D volumes were generated for wildtype and elastase mouse lung sections after semi-automated registration of all tissue slices. The 1D mean linear intercept (Lm) for wildtype (WT) (47.1 μm +/- 9.8 μm) and elastase mouse lung (64.5 μm +/- 14.0 μm) was significantly different (p<.001). We also generated 3D measurements based on tissue and airspace morphometry from the 3D volumes and all of these were significantly different (p<.0001) when comparing elastase and WT mouse lung. The ratio of the airspace-to-lung volume for the entire lung volume was also significantly and strongly correlated with Lm.

  2. Three dimensional transport model for toroidal plasmas

    International Nuclear Information System (INIS)

    Copenhauer, C.

    1980-12-01

    A nonlinear MHD model, developed for three-dimensional toroidal geometries (asymmetric) and for high β (β approximately epsilon), is used as a basis for a three-dimensional transport model. Since inertia terms are needed in describing evolving magnetic islands, the model can calculate transport, both in the transient phase before nonlinear saturation of magnetic islands and afterwards on the resistive time scale. In the β approximately epsilon ordering, the plasma does not have sufficient energy to compress the parallel magnetic field, which allows the Alfven wave to be eliminated in the reduced nonlinear equations, and the model then follows the slower time scales. The resulting perpendicular and parallel plasma drift velocities can be identified with those of guiding center theory

  3. Possibility of estimating three-dimensional mandibular morphology by cephalogram analysis

    International Nuclear Information System (INIS)

    Kim, S.; Motegi, Etsuko; Kikuchi, Yu; Yamaguchi, Hideharu; Takaki, Takashi; Shibahara, Takahiko

    2007-01-01

    The purpose of this study was to investigate the possibility of a surmise of three-dimensional mandibular morphology by two-dimensional cephalogram analysis. The materials were three-dimensional CT and cephalogram of 20 female mandibular prognathism patients (average age: 25.20±7.49) before there orthognathic surgery. Mandibular bone volume and sponge bone width were calculated from three-dimensional images constructed from CT images using imaging software (Real Intage, KGT inc.). There was a positive correlation (r=0.72) between mandibular volume value and mandibular ramus width. There was a positive correlation between sponge bone width at the site of the mandibular cuspid and mandibular ramus width and SNB angle (r=0.80), and between sponge bone width at the site of the mandibular molar and symphysis height and mandibular ramus width (r=0.81). It was thought that these results will be useful for a surmise of three-dimensional mandibular morphology by cephalogram analysis. (author)

  4. Self-consistent field theory of tethered polymers: one dimensional, three dimensional, strong stretching theories and the effects of excluded-volume-only interactions.

    Science.gov (United States)

    Suo, Tongchuan; Whitmore, Mark D

    2014-11-28

    We examine end-tethered polymers in good solvents, using one- and three-dimensional self-consistent field theory, and strong stretching theories. We also discuss different tethering scenarios, namely, mobile tethers, fixed but random ones, and fixed but ordered ones, and the effects and important limitations of including only binary interactions (excluded volume terms). We find that there is a "mushroom" regime in which the layer thickness is independent of the tethering density, σ, for systems with ordered tethers, but we argue that there is no such plateau for mobile or disordered anchors, nor is there one in the 1D theory. In the other limit of brushes, all approaches predict that the layer thickness scales linearly with N. However, the σ(1/3) scaling is a result of keeping only excluded volume interactions: when the full potential is included, the dependence is faster and more complicated than σ(1/3). In fact, there does not appear to be any regime in which the layer thickness scales in the combination Nσ(1/3). We also compare the results for two different solvents with each other, and with earlier Θ solvent results.

  5. Self-consistent field theory of tethered polymers: One dimensional, three dimensional, strong stretching theories and the effects of excluded-volume-only interactions

    International Nuclear Information System (INIS)

    Suo, Tongchuan; Whitmore, Mark D.

    2014-01-01

    We examine end-tethered polymers in good solvents, using one- and three-dimensional self-consistent field theory, and strong stretching theories. We also discuss different tethering scenarios, namely, mobile tethers, fixed but random ones, and fixed but ordered ones, and the effects and important limitations of including only binary interactions (excluded volume terms). We find that there is a “mushroom” regime in which the layer thickness is independent of the tethering density, σ, for systems with ordered tethers, but we argue that there is no such plateau for mobile or disordered anchors, nor is there one in the 1D theory. In the other limit of brushes, all approaches predict that the layer thickness scales linearly with N. However, the σ 1/3 scaling is a result of keeping only excluded volume interactions: when the full potential is included, the dependence is faster and more complicated than σ 1/3 . In fact, there does not appear to be any regime in which the layer thickness scales in the combination Nσ 1/3 . We also compare the results for two different solvents with each other, and with earlier Θ solvent results

  6. Verification of the three-dimensional FLAME code

    International Nuclear Information System (INIS)

    Mays, C.W.

    1976-08-01

    FLAME calculations are compared with operating data from Oconee Unit 1 and with two independent three-dimensional PDQ07 calculations for a feed-and-bleed plant containing lumped burnable poison. The Oconee 1 comparisons consider both steady-state and transient data. The steady-state calculations are compared with operating data from two cycles of operation. The comparisons with PDQ07 calculations are for a design transient. Direct comparisons are made between calculations and measurements for the Oconee 1 analyses. No uncertainty is applied to measured power densities. The difference in measured and calculated total peak for 95% of the assemblies considered in these comparisons is less than 5.3%. Based on these analyses, it is concluded that FLAME can calculate the total peak to within 5.3% for both steady-state and transient plant conditions. The maximum deviation in the total peak calculated by FLAME and one of the PDQ07 calculations is 5.6%. The maximum deviation with the other PDQ07 calculation is 2.5%. It is concluded that the FLAME calculations gave the most conservative results of the three

  7. Assessment of placental volume and vascularization at 11-14 weeks of gestation in a Taiwanese population using three-dimensional power Doppler ultrasound.

    Science.gov (United States)

    Wang, Hsing-I; Yang, Ming-Jie; Wang, Peng-Hui; Wu, Yi-Cheng; Chen, Chih-Yao

    2014-12-01

    The placental volume and vascular indices are crucial in helping doctors to evaluate early fetal growth and development. Inadequate placental volume or vascularity might indicate poor fetal growth or gestational complications. This study aimed to evaluate the placental volume and vascular indices during the period of 11-14 weeks of gestation in a Taiwanese population. From June 2006 to September 2009, three-dimensional power Doppler ultrasound was performed in 222 normal pregnancies from 11-14 weeks of gestation. Power Doppler ultrasound was applied to the placenta and the placental volume was obtained by a rotational technique (VOCAL). The three-dimensional power histogram was used to assess the placental vascular indices, including the mean gray value, the vascularization index, the flow index, and the vascularization flow index. The placental vascular indices were then plotted against gestational age (GA) and placental volume. Our results showed that the linear regression equation for placental volume using gestational week as the independent variable was placental volume = 18.852 × GA - 180.89 (r = 0.481, p power Doppler ultrasonography showed a constant distribution throughout gestation. Copyright © 2014. Published by Elsevier Taiwan.

  8. Full three-dimensional isotropic carpet cloak designed by quasi-conformal transformation optics.

    Science.gov (United States)

    Silva, Daniely G; Teixeira, Poliane A; Gabrielli, Lucas H; Junqueira, Mateus A F C; Spadoti, Danilo H

    2017-09-18

    A fully three-dimensional carpet cloak presenting invisibility in all viewing angles is theoretically demonstrated. The design is developed using transformation optics and three-dimensional quasi-conformal mapping. Parametrization strategy and numerical optimization of the coordinate transformation deploying a quasi-Newton method is applied. A discussion about the minimum achievable anisotropy in the 3D transformation optics is presented. The method allows to reduce the anisotropy in the cloak and an isotropic medium could be considered. Numerical simulations confirm the strategy employed enabling the design of an isotropic reflectionless broadband carpet cloak independently of the incident light direction and polarization.

  9. Quasi-three dimensional dynamic modeling of a proton exchange membrane fuel cell with consideration of two-phase water transport through a gas diffusion layer

    International Nuclear Information System (INIS)

    Kang, Sanggyu

    2015-01-01

    Water management is one of the challenging issues for low-temperature PEMFCs (proton exchange membrane fuel cells). When liquid water is formed at the GDL (gas diffusion layer), the pathway of reactant gas can be blocked, which inhibits the electrochemical reaction of PEMFC. Thus, liquid water transport through GDL is a critical factor determining the performance of a PEMFC. In present study, quasi-three dimensional dynamic modeling of PEMFC with consideration of two-phase water transport through GDL is developed. To investigate the distributions of PEMFC characteristics, including current density, species mole fraction, and membrane hydration, the PEMFC was discretized into twenty control volumes along the anode channel. To resolve the mass and energy conservation, the PEMFC is discretized into eleven and fifteen control volumes in the perpendicular direction, respectively. The dynamic variation of PEMFC characteristics of cell voltage, overvoltage of activation and ohmic, liquid water saturation through a GDL, and oxygen concentration were captured during transient behavior. - Highlights: • A quasi-three dimensional two-phase dynamic model of PEMFC is developed. • Presented model is validated by comparison with experimental data. • Two-phase model is compared with one-phase model at steady-states and transients.

  10. SCORE-EVET: a computer code for the multidimensional transient thermal-hydraulic analysis of nuclear fuel rod arrays. [BWR; PWR

    Energy Technology Data Exchange (ETDEWEB)

    Benedetti, R. L.; Lords, L. V.; Kiser, D. M.

    1978-02-01

    The SCORE-EVET code was developed to study multidimensional transient fluid flow in nuclear reactor fuel rod arrays. The conservation equations used were derived by volume averaging the transient compressible three-dimensional local continuum equations in Cartesian coordinates. No assumptions associated with subchannel flow have been incorporated into the derivation of the conservation equations. In addition to the three-dimensional fluid flow equations, the SCORE-EVET code ocntains: (a) a one-dimensional steady state solution scheme to initialize the flow field, (b) steady state and transient fuel rod conduction models, and (c) comprehensive correlation packages to describe fluid-to-fuel rod interfacial energy and momentum exchange. Velocity and pressure boundary conditions can be specified as a function of time and space to model reactor transient conditions such as a hypothesized loss-of-coolant accident (LOCA) or flow blockage.

  11. Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Mori, Koichi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute and MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5 T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI. (author)

  12. [Effects of the volume and shape of voxels on the measurement of phantom volume using three-dimensional magnetic resonance imaging].

    Science.gov (United States)

    Mori, Koichi; Hagino, Hirofumi; Saitou, Osamu; Yotsutsuji, Takashi; Tonami, Syuichi; Nakamura, Mamoru; Kuranishi, Makoto

    2002-01-01

    Recently, an increasing number of volumetric studies of the human brain have been reported, using three-dimensional magnetic resonance imaging (3D-MRI). To our knowledge, however, there are few investigations on the relation of the volume and shape of voxels which constitute an MR image to the accuracy in volume measurement of an imaged object. The purpose of this study was to evaluate the effect of a different shape of voxel, that is, isotropic or anisotropic, as well as the volume of a voxel on the volume measurement based on the original image data and multiplanar reconstruction (MPR) data, respectively. In the experiment, we repeatedly acquired contiguous sagittal images of a single globe phantom with a known volume under the condition in which the volume and shape of voxels varied, on a 1.5T MR scanner. We used a gradient echo sequence (3D FLASH). The volume of the globe phantom from both original images and MPR ones was measured on workstations employing a semi-automated local thresholding technique. As a result, the smaller volume of voxels tended to give us the more correct measurement, and an isotropic voxel reduced measurement errors as compared to an anisotropic one. Therefore, it is concluded that the setting of voxel with both an isotropic shape and small volume, e.g., a voxel of 1 mm x 1 mm x 1 mm at present, is recommended in order to get a precise volume measurement using 3D-MRI.

  13. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    Directory of Open Access Journals (Sweden)

    Arheden Håkan

    2011-04-01

    Full Text Available Abstract Background Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Methods Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Results Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Conclusion Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking

  14. Low dimensional equivalence of core neutronics model and its application to transient analysis

    International Nuclear Information System (INIS)

    Song Hongbing; Zhao Fuyu

    2015-01-01

    Three-dimensional coupled neutronics thermal-hydraulics reactor analysis is time consuming and occupies huge memory. A one-dimensional model is preferable than the three one in nuclear system analysis, control system design and load following. In this paper, a corewide three dimensional to one dimensional equivalent method has been developed. On the basis of this method 1D axial few groups constants were obtained. The equivalent cross sections were calculated by general spatial homogenization while the transverse buckling was computed through an equivalence based on the 3D flux conservation. Three steady test cases were performed on one dimensional finite difference code ODTAC and the results were compared with TRIVAC-5. The comparison shows that the one dimensional axial power distribution computed by ODTAC correlates well with the three dimensional results calculated by TRIVAC-5. In this study, DRAGON-4 was used to generate the few-group constants of fuel assemblies and the reflector few-group parameters were calculated by WIMS-D4. These collapsed few-group constants were tabulated in a database sorted in ascending order of fuel temperature, coolant temperature and concentration of boric acid. Trilinear interpolation was adopted in cross sections feedback during the transient analysis. In this paper, G1 rod drop accident (RDA) and G1 rod ejection accident (REA) were performed on ODTAC and the computation results were consistent of the physical rules. (author)

  15. Advanced numerical methods for three dimensional two-phase flow calculations in PWR

    International Nuclear Information System (INIS)

    Toumi, I.; Gallo, D.; Royer, E.

    1997-01-01

    This paper is devoted to new numerical methods developed for three dimensional two-phase flow calculations. These methods are finite volume numerical methods. They are based on an extension of Roe's approximate Riemann solver to define convective fluxes versus mean cell quantities. To go forward in time, a linearized conservative implicit integrating step is used, together with a Newton iterative method. We also present here some improvements performed to obtain a fully implicit solution method that provides fast running steady state calculations. This kind of numerical method, which is widely used for fluid dynamic calculations, is proved to be very efficient for the numerical solution to two-phase flow problems. This numerical method has been implemented for the three dimensional thermal-hydraulic code FLICA-4 which is mainly dedicated to core thermal-hydraulic transient and steady-state analysis. Hereafter, we will also find some results obtained for the EPR reactor running in a steady-state at 60% of nominal power with 3 pumps out of 4, and a thermal-hydraulic core analysis for a 1300 MW PWR at low flow steam-line-break conditions. (author)

  16. Evaluation of anterior pituitary gland volume in childhood using three-dimensional MRI

    International Nuclear Information System (INIS)

    Marziali, Simone; Gaudiello, Fabrizio; Ferone, Ernesto; Colangelo, Vittorio; Floris, Roberto; Simonetti, Giovanni; Bozzao, Alessandro; Scire, Giuseppe; Simonetti, Alessandra; Boscherini, Brunetto

    2004-01-01

    Background: Three-dimensional MRI (3D-MRI) is a reliable tool for the evaluation of anatomical volumes. Volumetric measurement of the normal anterior pituitary gland in childhood has been performed in the past by 2D-MRI calculations, but has inherent inaccuracies. Objective: To obtain accurate normal anterior pituitary gland volume in childhood using 3D-MRI coronal sections. Materials and methods: The anterior pituitary gland was measured using coronal T1-weighted 3D-gradient-echo sequences (section thickness 0.75 mm). The study group was composed of 95 prepubertal children (age range 2 months-10 years) with clinically normal pituitary function and no pituitary or brain abnormalities. Results: A measurement error of 0.2-0.4% was assessed by using a phantom study. Volumetric evaluation of the anterior pituitary gland showed progressive growth of the gland from a mean 131±24 mm 3 at 2-12 months, to 249±25 mm 3 at 1-4 years and 271±29 mm 3 at 5-10 years. Conclusions: These data may be useful for paediatricians in the evaluation of patients with neuroendocrine diseases, in particular growth hormone deficiency. (orig.)

  17. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  18. Advantages of three-dimensional treatment planning in radiation therapy

    International Nuclear Information System (INIS)

    Attalla, E.M.; ELSAyed, A.A.; ElGantiry, M.; ElTahher, Z.

    2003-01-01

    This study was designed to demonstrate the feasibility of three-dimensional (3-D) treatment planning in-patients maxilla, breast, bladder, and lung tumors to explore its potential therapeutic advantage over the traditional dimensional (2-D) approach in these diseases. Conventional two-dimensional (2-D) treatment planning was compared to three-dimensional (3-D) treatment planning. In five selected disease sites, plans calculated with both types of treatment planning were compared. The (3-D) treatment planning system used in this work TMS version 5.1 B from helax AB is based on a monte Carlo-based pencil beam model. The other treatment planning system (2-D 0, introduced in this study was the multi data treatment planning system version 2.35. For the volumes of interest; quality of dose distribution concerning homogeneity in the target volume and the isodose distribution in organs at risk, was discussed. Qualitative and quantitative comparisons between the two planning systems were made using dose volume histograms (DVH's) . For comparisons of dose distributions in real-patient cases, differences ranged from 0.8% to 6.4% for 6 MV, while in case of 18 MV photon, it ranged from 1,8% to 6.5% and was within -+3 standard deviations for the dose between the two planning systems.Dose volume histogram (DVH) shows volume reduction of the radiation-related organs at risk 3-D planning

  19. Three-dimensional whole-brain perfused blood volume imaging with multimodal CT for evaluation of acute ischaemic stroke

    International Nuclear Information System (INIS)

    Lu, J.; Zhang, M.; Cao, Y.; Ma, Q.; Chen, J.; Ji, X.; Li, K.

    2011-01-01

    Aim: To determine the diagnostic value of integrating three-dimensional perfused blood volume (3D PBV) with multimodal computed tomography (CT) [non-enhanced CT (NECT), CT perfusion (CTP), and CT angiography (CTA)] in acute ischaemic stroke. Materials and methods: NECT, CTP, and CTA were performed in 25 acute ischaemic stroke patients. The ischaemia detection rate of 3D PBV was compared with the results of baseline NECT and CTP. The correlation of ischaemic lesion volume between 3D PBV, CTP images, and follow-up NECT were analysed. Results: NECT demonstrated ischaemic signs in 12 of 25 patients with proven infarction. CTP maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and time to peak (TTP) all demonstrated perfusion deficits in 21 of 25 patients. However, 3D PBV demonstrated perfusion deficits in all of the 25 patients. Among the 25 patients, a strong correlation was found between PBV and the follow-up NECT infarct (r = 0.858). The correlation between CTP and the follow-up NECT infarct as following: CBF (r = 0.718), CBV (r = 0.785), and TTP (r = 0.569). In 14 thrombolytic patients, strong correlation was found between the ischaemic volume on 3D PBV and follow-up NECT (r = 0.798). Conclusion: In acute stroke patients, the combination of 3D PBV and multimodal CT (NECT, CTP, and CTA) can improve the detection rate of ischaemia and enable assessment of the full extent of ischaemia, which correlates well with follow-up NECT.

  20. Three-dimensional multi-physics coupled simulation of ignition transient in a dual pulse solid rocket motor

    Science.gov (United States)

    Li, Yingkun; Chen, Xiong; Xu, Jinsheng; Zhou, Changsheng; Musa, Omer

    2018-05-01

    In this paper, numerical investigation of ignition transient in a dual pulse solid rocket motor has been conducted. An in-house code has been developed in order to solve multi-physics governing equations, including unsteady compressible flow, heat conduction and structural dynamic. The simplified numerical models for solid propellant ignition and combustion have been added. The conventional serial staggered algorithm is adopted to simulate the fluid structure interaction problems in a loosely-coupled manner. The accuracy of the coupling procedure is validated by the behavior of a cantilever panel subjected to a shock wave. Then, the detailed flow field development, flame propagation characteristics, pressure evolution in the combustion chamber, and the structural response of metal diaphragm are analyzed carefully. The burst-time and burst-pressure of the metal diaphragm are also obtained. The individual effects of the igniter's mass flow rate, metal diaphragm thickness and diameter on the ignition transient have been systemically compared. The numerical results show that the evolution of the flow field in the combustion chamber, the temperature distribution on the propellant surface and the pressure loading on the metal diaphragm surface present a strong three-dimensional behavior during the initial ignition stage. The rupture of metal diaphragm is not only related to the magnitude of pressure loading on the diaphragm surface, but also to the history of pressure loading. The metal diaphragm thickness and diameter have a significant effect on the burst-time and burst-pressure of metal diaphragm.

  1. The three-dimensional transient two-phase flow computer programme BACCHUS-3D/TP

    International Nuclear Information System (INIS)

    Bottoni, M.; Dorr, B.; Homann, C.

    1992-04-01

    The three-dimensional single-phase flow version of the BACCHUS code, which describes the thermal behaviour of a coolant in hexagonal bundle geometry, developed earlier, provided the basis for the development of the two-phase flow version documented in this report. A detailed description is given of the two-phase Slip Model (SM), and of the Homogeneous Equilibrium Model (HEM) as a subcase, which presents several improvements from both viewpoints of physical modelling and numerical treatment, with respect to usual models found in the literature. The most advanced Separated Phases Model (SPM) is then described in all analytical details necessary to fully understand its implementation in the code. Poblems related to the link between the two above models into an integrated code version are then discussed. The code provides an additional option for modelling of active or passive, permeable or impermeable blockages. This option is documented separately. New numerical methods for solving the algebraic systems of equations derived from the linearization of the fundamental equations have completely superseded previous ones and are explained in detail. Eventually a section is dedicated to an overview of the code verification, made over several years, which goes from steady state single-phase unheated bundle experiments up to fast transient two-phase flow experiments in electrically heated 37-pin bundles. (orig.) [de

  2. Continuation of full-scale three-dimensional numerical experiments on high-intensity particle and laser beam-matter interactions

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Warren, B.

    2012-12-01

    We present results from the grant entitled, Continuation of full-scale three-dimensional numerical experiments on high-intensity particle and laser beam-matter interactions. The research significantly advanced the understanding of basic high-energy density science (HEDS) on ultra intense laser and particle beam plasma interactions. This advancement in understanding was then used to to aid in the quest to make 1 GeV to 500 GeV plasma based accelerator stages. The work blended basic research with three-dimensions fully nonlinear and fully kinetic simulations including full-scale modeling of ongoing or planned experiments. The primary tool was three-dimensional particle-in-cell simulations. The simulations provided a test bed for theoretical ideas and models as well as a method to guide experiments. The research also included careful benchmarking of codes against experiment. High-fidelity full-scale modeling provided a means to extrapolate parameters into regimes that were not accessible to current or near term experiments, thereby allowing concepts to be tested with confidence before tens to hundreds of millions of dollars were spent building facilities. The research allowed the development of a hierarchy of PIC codes and diagnostics that is one of the most advanced in the world.

  3. PIV measurements in a microfluidic 3D-sheathing structure with three-dimensional flow behaviour

    DEFF Research Database (Denmark)

    Klank, Henning; Goranovic, Goran; Kutter, Jörg Peter

    2002-01-01

    . The structures are often of complex geometry and include strongly three-dimensional flow behaviour, which poses a challenge for the micro particle image velocimetry (micro-PIV) technique. The flow in a microfluidic 3D-sheathing structure has been measured throughout the volume using micro-PIV. In addition......, a stereoscopic principle was applied to obtain all three velocity components, showing the feasibility of obtaining full volume mapping (x, y, z, U, V, W) from micro-PIV measurements. The results are compared with computational fluid dynamics (CFD) simulations....

  4. The application of finite volume methods for modelling three-dimensional incompressible flow on an unstructured mesh

    Science.gov (United States)

    Lonsdale, R. D.; Webster, R.

    This paper demonstrates the application of a simple finite volume approach to a finite element mesh, combining the economy of the former with the geometrical flexibility of the latter. The procedure is used to model a three-dimensional flow on a mesh of linear eight-node brick (hexahedra). Simulations are performed for a wide range of flow problems, some in excess of 94,000 nodes. The resulting computer code ASTEC that incorporates these procedures is described.

  5. Three-dimensional reconstruction and visualization system for medical images

    International Nuclear Information System (INIS)

    Preston, D.F.; Batnitzky, S.; Kyo Rak Lee; Cook, P.N.; Cook, L.T.; Dwyer, S.J.

    1982-01-01

    A three-dimensional reconstruction and visualization system could be of significant advantage in medical application such as neurosurgery and radiation treatment planning. The reconstructed anatomic structures from CT head scans could be used in a head stereotactic system to help plan the surgical procedure and the radiation treatment for a brain lesion. Also, the use of three-dimensional reconstruction algorithm provides for quantitative measures such as volume and surface area estimation of the anatomic features. This aspect of the three-dimensional reconstruction system may be used to monitor the progress or staging of a disease and the effects of patient treatment. Two cases are presented to illustrate the three-dimensional surface reconstruction and visualization system

  6. [Measurement of the frontal and prefrontal lobe volumes in children with malnutrition by three dimensional magnetic resonance imaging scan].

    Science.gov (United States)

    Kanemura, Hideaki; Aihara, Masao; Nakazawa, Shinpei

    2002-09-01

    To evaluate the effects of malnutrition in early life on the growth of the frontal and prefrontal lobes, we quantitatively measured the volumes of the frontal and prefrontal lobes by three dimensional (3-D) MRI in three children (1 year 2 months to 2 years 5 months) with malnutrition. The 3-D MRI data were acquired by the fast spoiled gradient recalled (SPGR) sequence using a 1.5T MR imager. The frontal and prefrontal lobe volumes were measured by the volume measurement function of the Workstation. The data obtained were compared with those of 16 normal subjects (13 children aged 5 months to 14 years, and 3 adults aged 27 to 39 years). The volumes of the frontal and prefrontal lobes in the subjects were smaller compared with age matched controls. The results suggest that malnutrition in early life affects the growth of the frontal and prefrontal lobes.

  7. Comparison of planning target volumes based on three-dimensional and four-dimensional CT imaging of thoracic esophageal cancer

    Directory of Open Access Journals (Sweden)

    Wang W

    2016-08-01

    Full Text Available Wei Wang, Jianbin Li, Yingjie Zhang, Qian Shao, Min Xu, Tingyong Fan, Jinzhi Wang Department of Radiation Oncology, Shandong Cancer Hospital Affiliated to Shandong University, Shandong Academy of Medical Sciences, Shandong, People’s Republic of China Background and purpose: To investigate the definition of planning target volumes (PTVs based on four-dimensional computed tomography (4DCT compared with conventional PTV definition and PTV definition using asymmetrical margins for thoracic primary esophageal cancer. Materials and methods: Forty-three patients with esophageal cancer underwent 3DCT and 4DCT simulation scans during free breathing. The motions of primary tumors located in the proximal (group A, middle (group B, and distal (group C thoracic esophagus were obtained from the 4DCT scans. PTV3D was defined on 3DCT using the tumor motion measured based on 4DCT, PTV conventional (PTVconv was defined on 3DCT by adding a 1.0 cm margin to the clinical target volume, and PTV4D was defined as the union of the target volumes contoured on the ten phases of the 4DCT images. The centroid positions, volumetric differences, and dice similarity coefficients were evaluated for all PTVs. Results: The median centroid shifts between PTV3D and PTV4D and between PTVconv and PTV4D in all three dimensions were <0.3 cm for the three groups. The median size ratios of PTV4D to PTV3D were 0.80, 0.88, and 0.71, and PTV4D to PTVconv were 0.67, 0.73, and 0.76 (χ2=–3.18, –2.98, and –3.06; P=0.001, 0.003, and 0.002 for groups A, B, and C, respectively. The dice similarity coefficients were 0.87, 0.90, and 0.81 between PTV4D and PTV3D and 0.80, 0.84, and 0.83 between PTV4D and PTVconv (χ2=–3.18, –2.98, and –3.06; P=0.001, 0.003, and 0.002 for groups A, B, and C, respectively. The difference between the degree of inclusion of PTV4D in PTV3D and that of PTV4D in PTVconv was <2% for all groups. Compared with PTVconv, the amount of irradiated normal tissue

  8. Verification of the three-dimensional FLAME code

    International Nuclear Information System (INIS)

    Mays, C.W.

    1976-04-01

    FLAME calculations are compared with operating data from Oconee Unit 1 and with two independent three-dimensional PDQ07 calculations for a feed-and-bleed plant containing lumped burnable poison. The Oconee 1 comparisons consider both steady-state and transient data.The steady-state calculations are compared with operating data from two cycles of operation. The comparisons with PDQ07 calculations are for a design transient. Direct comparisons are made between calculations and measurements for the Oconee 1 analyses. No uncertainty is applied to measured power densities. The difference in measured and calculated total peak for 95 percent of the assemblies considered in these comparisons is less than 5.3 percent. Based on these analyses, it is concluded that FLAME can calculate the total peak to within 5.3 percent for both steady-state and transient plant conditions. The maximum deviation in the total peak calculated by FLAME and one of the PDQ07 calculations is 5.6 percent. The maximum deviation with the other PDQ07 calculation is 2.5 percent. It is concluded that the FLAME calculations gave the most conservative results of the three

  9. Quantitative grain-scale ferroic domain volume fractions and domain switching strains from three-dimensional X-ray diffraction data

    DEFF Research Database (Denmark)

    Oddershede, Jette; Majkut, Marta; Caosyd, Qinghua

    2015-01-01

    A method for the extension of the three-dimensional X-ray diffraction technique to allow the extraction of domain volume fractions in polycrystalline ferroic materials is presented. This method gives access to quantitative domain volume fractions of hundreds of independent embedded grains within...... are applied to tetragonal coarse-grained Ba0.88Ca0.12Zr0.06Ti0.94O3 and rhombohedral fine-grained (0.82)Bi0.5Na0.5TiO3–(0.18)Bi0.5K0.5TiO3 electroceramic materials. The fitted volume fraction information is used to calculate grain-scale non-180° ferroelectric domain switching strains. The absolute errors...

  10. THREE-DIMENSIONAL ASSESSMENT OF THE PHARYNGEAL AIRWAY AND MAXILLARY SINUS VOLUMES IN INDIVIDUALS WITH NON-SYNDROMIC CLEFT LIP AND PALATE

    Directory of Open Access Journals (Sweden)

    Ana NEMȚOI

    2015-09-01

    Full Text Available Introduction: Children with cleft lip and palate (CLP are known to have airway problems. Introduction of ConeBeam CT (CBCT and imaging software has facilitated generation of 3D images for assessing the volume of maxillary sinuses and pharyngeal airway. Consequently, the present study aimed at evaluating and comparing the maxillary sinus and pharyngeal airway volume of patients with cleft lip and palate in healthy patients, using cone beam computed tomography (CBCT images. Materials and method: The sample group included 27 individuals (15 with cleft lip and palate subjects and 12 healthy subjects. The pharyngeal airway and each maxillary sinus were three-dimensionally assessed, segmented and their volume was calculated. A comparison between the right and left sinus was performed by Student t-test, and the differences between the control and cleft groups were calculated using ANOVA. Results: No statistically significant differences were found when the maxillary sinuses volumes from each side were compared (p >0.05. The unilateral CLP patients presented the lowest sinus volume. Individuals with CLP did not exhibit a total airway volume smaller than the nonCLP controls. Conclusions: 3D imaging using CBCT and Romexis software is reliable for assessing maxillary sinus and pharyngeal airway volume. The present study showed that the pharyngeal airway is not compromised in CLP individuals. The unilateral CLP individuals present maxillary sinuses with smaller volumes, no differences being recorded between the cleft and non-cleft side.

  11. Three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT: applications and limitations

    International Nuclear Information System (INIS)

    Kim, Su Yeon; Choi, Sun Seob; Kang, Myung Jin; Shin, Tae Beom; Lee, Ki Nam; Kang, Myung Koo

    2005-01-01

    This study was conducted to know the applications and limitations of three dimensional volume rendering virtual endoscopy of the ossicles using a multi-row detector CT. This study examined 25 patients who underwent temporal bone CT using a 16-row detector CT as a result of hearing problems or trauma. The axial CT scan of the temporal bone was performed with a 0.6 mm collimation, and a reconstruction was carried out with a U70u sharp of kernel value, a 1 mm thickness and 0.5-1.0 mm increments. After observing the ossicles in the axial and coronal images, virtual endoscopy was performed using a three dimensional volume rendering technique with a threshold value of-500 HU. The intra-operative otoendoscopy was performed in 12 ears, and was compared with the virtual endoscopy findings. Virtual endoscopy of the 29 ears without hearing problems demonstrated hypoplastic or an incomplete depiction of the stapes superstructures in 25 ears and a normal depiction in 4 ears. Virtual endoscopy of 21 ears with hearing problems demonstrated no ossicles in 1 ears, no malleus in 3 ears, a malleoincudal subluxation in 6 ears, a dysplastic incus in 5 ears, an incudostapedial subluxation in 9 ears, dysplastic stapes in 2 ears, a hypoplastic or incomplete depiction of the stapes in 16 ears and no stapes in 1 ears. In contrast to the intra-operative otoendoscopy, 8 out of 12 ears showed a hypoplastic or deformed stapes in the virtual endoscopy. Volume rendering virtual endoscopy using a multi-row detector CT is an excellent method for evaluation the ossicles in three dimension, even thought the partial volume effect for the stapes superstructures needs to be considered

  12. Clinical assessment of hypopharyngeal and laryngeal disorders by three-dimensional multidetector-row CT. Feasibility of imaging during phonation

    International Nuclear Information System (INIS)

    Tan, Xiaotian

    2002-01-01

    The hypopharynx and larynx can adapt their structures to physiological functions. To clarify the relation between morphologic changes and the development of pharyngeal and laryngeal disorders, images of the hypopharynx and larynx were obtained by multidetector-row CT (MD-CT) during phonation and quiet breathing. The clinical usefulness of such imaging study was assessed by comparing the images taken in the two phases. The study included 23 subjects, 20 patients with a hypopharyngeal or laryngeal disorder and 3 healthy volunteers. MD-CT scanning of the hypopharynx and larynx was not influenced by breathing and body movement. The volume rendering (VR) method was useful in that three-dimensional imaging could visualize the internal structure of the hypopharynx and larynx. Thus, the volume rendering method can be regarded as a virtual three-dimensional method. The normal anatomic structure of the hypopharynx and larynx were depicted in full and three-dimensionally. The extent of hypopharyngeal and laryngeal cancer was shown clearly. Edema due to paralysis of recurrent nerve was demonstrated in full and three-dimensionally, providing for functional diagnosis. In the case of mucosal edema caused by trauma, the extent of the edema and its effect on the airway were clearly observed. These results suggest that MD-CT with three-dimensional imaging during phonation is useful in the diagnosis of hypopharyngeal and laryngeal disorders. (author)

  13. Multi-scale computational model of three-dimensional hemodynamics within a deformable full-body arterial network

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Nan [Department of Bioengineering, Stanford University, Stanford, CA 94305 (United States); Department of Biomedical Engineering, King’s College London, London SE1 7EH (United Kingdom); Humphrey, Jay D. [Department of Biomedical Engineering, Yale University, New Haven, CT 06520 (United States); Figueroa, C. Alberto, E-mail: alberto.figueroa@kcl.ac.uk [Department of Biomedical Engineering, King’s College London, London SE1 7EH (United Kingdom)

    2013-07-01

    In this article, we present a computational multi-scale model of fully three-dimensional and unsteady hemodynamics within the primary large arteries in the human. Computed tomography image data from two different patients were used to reconstruct a nearly complete network of the major arteries from head to foot. A linearized coupled-momentum method for fluid–structure-interaction was used to describe vessel wall deformability and a multi-domain method for outflow boundary condition specification was used to account for the distal circulation. We demonstrated that physiologically realistic results can be obtained from the model by comparing simulated quantities such as regional blood flow, pressure and flow waveforms, and pulse wave velocities to known values in the literature. We also simulated the impact of age-related arterial stiffening on wave propagation phenomena by progressively increasing the stiffness of the central arteries and found that the predicted effects on pressure amplification and pulse wave velocity are in agreement with findings in the clinical literature. This work demonstrates the feasibility of three-dimensional techniques for simulating hemodynamics in a full-body compliant arterial network.

  14. Visual Interpretation with Three-Dimensional Annotations (VITA): three-dimensional image interpretation tool for radiological reporting.

    Science.gov (United States)

    Roy, Sharmili; Brown, Michael S; Shih, George L

    2014-02-01

    This paper introduces a software framework called Visual Interpretation with Three-Dimensional Annotations (VITA) that is able to automatically generate three-dimensional (3D) visual summaries based on radiological annotations made during routine exam reporting. VITA summaries are in the form of rotating 3D volumes where radiological annotations are highlighted to place important clinical observations into a 3D context. The rendered volume is produced as a Digital Imaging and Communications in Medicine (DICOM) object and is automatically added to the study for archival in Picture Archiving and Communication System (PACS). In addition, a video summary (e.g., MPEG4) can be generated for sharing with patients and for situations where DICOM viewers are not readily available to referring physicians. The current version of VITA is compatible with ClearCanvas; however, VITA can work with any PACS workstation that has a structured annotation implementation (e.g., Extendible Markup Language, Health Level 7, Annotation and Image Markup) and is able to seamlessly integrate into the existing reporting workflow. In a survey with referring physicians, the vast majority strongly agreed that 3D visual summaries improve the communication of the radiologists' reports and aid communication with patients.

  15. Three-dimensional investigation of the two-phase flow structure in a bubbly pipe flow

    International Nuclear Information System (INIS)

    Schmidl, W.; Hassan, Y.A.; Ortiz-Villafuerte, J.

    1996-01-01

    Particle image velocimetry (PIV) is a nonintrusive measurement technique that can be used to study the structure of various fluid flows. PIV is used to measure the time-varying, full-field velocity data of a particle-seeded flow field within either a two-dimensional plane or three-dimensional volume. PIV is a very efficient measurement technique since it can obtain both qualitative and quantitative spatial information about the flow field being studied. The quantitative spatial velocity information can be further processed into information of flow parameters such as vorticity and turbulence over extended areas. The objective of this study was to apply recent advances and improvements in the PIV flow measurement technique to the full-field, nonintrusive analysis of a three-dimensional, two-phase fluid flow system in such a manner that both components of the two-phase system could be experimentally quantified

  16. Assessment of maxillary sinus volume for the sinus lift operation by three-dimensional magnetic resonance imaging.

    Science.gov (United States)

    Gray, C F; Staff, R T; Redpath, T W; Needham, G; Renny, N M

    2000-05-01

    To calculate sinus and bone graft volumes and vertical bone heights from sequential magnetic resonance imaging (MRI) examinations in patients undergoing a sinus lift operation. MRI scans were obtained pre-operatively and at 10 days and 10 weeks post-operatively, using a 0.95 tesla MRI scanner and a three-dimensional (3D) magnetisation prepared, rapid acquisition gradient-echo (MP-RAGE) sequence. Estimates of the bone graft volumes required for a desired vertical bone height were made from the pre-operative MRI scan. Measurements of the graft volumes and bone heights actually achieved were made from the post-operative scans. The MRI appearance of the graft changed between the 10 day and 10 week scans. We have proposed a technique which has the potential to give the surgeon an estimate of the optimum volume of graft for the sinus lift operation from the pre-operative MRI scan alone and demonstrated its application in a single patient. Changes in the sequential MRI appearance of the graft are consistent with replacement of fluid by a matrix of trabecular bone.

  17. Three-dimensional magnetic field computation on a distributed memory parallel processor

    International Nuclear Information System (INIS)

    Barion, M.L.

    1990-01-01

    The analysis of three-dimensional magnetic fields by finite element methods frequently proves too onerous a task for the computing resource on which it is attempted. When non-linear and transient effects are included, it may become impossible to calculate the field distribution to sufficient resolution. One approach to this problem is to exploit the natural parallelism in the finite element method via parallel processing. This paper reports on an implementation of a finite element code for non-linear three-dimensional low-frequency magnetic field calculation on Intel's iPSC/2

  18. Transient two-dimensional flow in porous media

    International Nuclear Information System (INIS)

    Sharpe, L. Jr.

    1979-01-01

    The transient flow of an isothermal ideal gas from the cavity formed by an underground nuclear explosion is investigated. A two-dimensional finite element method is used in analyzing the gas flow. Numerical results of the pressure distribution are obtained for both the stemming column and the surrounding porous media

  19. Computational methods for three-dimensional microscopy reconstruction

    CERN Document Server

    Frank, Joachim

    2014-01-01

    Approaches to the recovery of three-dimensional information on a biological object, which are often formulated or implemented initially in an intuitive way, are concisely described here based on physical models of the object and the image-formation process. Both three-dimensional electron microscopy and X-ray tomography can be captured in the same mathematical framework, leading to closely-related computational approaches, but the methodologies differ in detail and hence pose different challenges. The editors of this volume, Gabor T. Herman and Joachim Frank, are experts in the respective methodologies and present research at the forefront of biological imaging and structural biology.   Computational Methods for Three-Dimensional Microscopy Reconstruction will serve as a useful resource for scholars interested in the development of computational methods for structural biology and cell biology, particularly in the area of 3D imaging and modeling.

  20. Two- and three-dimensional CT analysis of ankle fractures

    International Nuclear Information System (INIS)

    Magid, D.; Fishman, E.K.; Ney, D.R.; Kuhlman, J.E.

    1988-01-01

    CT with coronal and sagittal reformatting (two-dimensional CT) and animated volumetric image rendering (three-dimensional CT) was used to assess ankle fractures. Partial volume limits transaxial CT in assessments of horizontally oriented structures. Two-dimensional CT, being orthogonal to the plafond, superior mortise, talar dome, and tibial epiphysis, often provides the most clinically useful images. Two-dimensional CT is most useful in characterizing potentially confusing fractures, such as Tillaux (anterior tubercle), triplane, osteochondral talar dome, or nondisplaced talar neck fractures, and it is the best study to confirm intraarticular fragments. Two-and three-dimensional CT best indicate the percentage of articular surface involvement and best demonstrate postoperative results or complications (hardware migration, residual step-off, delayed union, DJD, AVN, etc). Animated three-dimensional images are the preferred means of integrating the two-dimensional findings for surgical planning, as these images more closely simulate the clinical problem

  1. Three-dimensional configuration and damping effect of flare coronal transients

    International Nuclear Information System (INIS)

    Ivanov, K.G.; Kharshiladze, A.F.

    1989-01-01

    Inverse problem of searching for three - dimensional configuration of coronal mass outburst (CMO) in the class of flattened spheroids was solved on the basis of solving primal problem of projecting CMO of the given configuration on celestial plane, using experimental data of white light coronograph. It was obtained that CMO, as interplanetary shock waves, were oblate with ∼ 1.25 ratio of axes to the plane of great circle, passing through the flare, parallel to magnetic axis of the nearest bipolar group

  2. Relationship between Plasma D-Dimer Concentration and Three-Dimensional Ultrasound Placental Volume in Women at Risk for Placental Vascular Diseases: A Monocentric Prospective Study.

    Directory of Open Access Journals (Sweden)

    Cécile Fanget

    Full Text Available The aim of this study was to correlate placental volumes deduced from three-dimensional ultrasound and virtual organ computer-aided analysis (VOCAL software with systemic concentrations of D-dimer and soluble endothelial protein C receptor (sEPCR.This was a monocentric experimental prospective study conducted from October 2008 to July 2009. Forty consecutive patients at risk of placental vascular pathology (PVP recurrence or occurrence were included. Placental volumes were systematically measured three times (11-14, 16-18 and 20-22 weeks of gestation (WG by two independent sonographers. D-dimers and sEPCR plasma concentrations were measured using ELISA kits (Enzyme Linked ImmunoSorbent Assay.Eleven patients had a PVP. The plasma D-dimer level was positively correlated with placental volume (r = 0.45, p < 0.001. A smaller placental volume and placental quotient was evidenced in women who developed a PVP at the three gestational ages, and the difference was more pronounced during the third exam (20 WG. No obvious correlation could be demonstrated between the development of a PVP and the levels of D-dimer and sEPCR. There was no significant difference in the values of placental volumes measured by the two sonographers.The placenta growth could be a major determinant of the elevation of D-dimer during pregnancy. Consideration of placental volume could allow for modulation of the D-dimer concentrations for restoring their clinical interest.

  3. Three-dimensional fluorescence lifetime tomography

    International Nuclear Information System (INIS)

    Godavarty, Anuradha; Sevick-Muraca, Eva M.; Eppstein, Margaret J.

    2005-01-01

    Near-infrared fluorescence tomography using molecularly targeted lifetime-sensitive, fluorescent contrast agents have applications for early-stage cancer diagnostics. Yet, although the measurement of fluorescent lifetime imaging microscopy (FLIM) is extensively used in microscopy and spectroscopy applications, demonstration of fluorescence lifetime tomography for medical imaging is limited to two-dimensional studies. Herein, the feasibility of three-dimensional fluorescence-lifetime tomography on clinically relevant phantom volumes is established, using (i) a gain-modulated intensified charge coupled device (CCD) and modulated laser diode imaging system, (ii) two fluorescent contrast agents, e.g., Indocyanine green and 3-3'-Diethylthiatricarbocyanine iodide differing in their fluorescence lifetime by 0.62 ns, and (iii) a two stage approximate extended Kalman filter reconstruction algorithm. Fluorescence measurements of phase and amplitude were acquired on the phantom surface under different target to background fluorescence absorption (70:1, 100:1) and fluorescence lifetime (1:1, 2.1:1) contrasts at target depths of 1.4-2 cm. The Bayesian tomography algorithm was employed to obtain three-dimensional images of lifetime and absorption owing to the fluorophores

  4. Progress of radiotherapy by three-dimensional treatment planning

    International Nuclear Information System (INIS)

    Imada, Hajime; Nomoto, Satoshi; Takahashi, Hiroyuki; Nakata, Hajime

    1998-01-01

    The recent progress of three-dimensional radiation treatment planning was reviewed. And clinical cases such as lung cancer and breast cancer are introduced. In the University of Occupational and Development Health, the treatment system FOCUS which is made up of CT simulator and linac was used mainly. Three-dimensional treatment planning was carried for about 90% of 330 patients who underwent radiotherapy for one year. The target becomes to be accurate and dose distribution with all CT slices in radiation field can be confirmed by using three-dimensional radiation treatment planning apparatus. High dose irradiation localized to tumor part is possible. Relations between total dose and volume of normal tissue and/or tumor can be estimated numerically and easily by DVH. A prediction of indication and affection became possible by this procedure. In conclusion, generalization of three-dimensional radiation treatment planning will bring progress of more effective radiotherapy with less adverse reaction. (K.H.). 21 refs

  5. A web service system supporting three-dimensional post-processing of medical images based on WADO protocol.

    Science.gov (United States)

    He, Longjun; Xu, Lang; Ming, Xing; Liu, Qian

    2015-02-01

    Three-dimensional post-processing operations on the volume data generated by a series of CT or MR images had important significance on image reading and diagnosis. As a part of the DIOCM standard, WADO service defined how to access DICOM objects on the Web, but it didn't involve three-dimensional post-processing operations on the series images. This paper analyzed the technical features of three-dimensional post-processing operations on the volume data, and then designed and implemented a web service system for three-dimensional post-processing operations of medical images based on the WADO protocol. In order to improve the scalability of the proposed system, the business tasks and calculation operations were separated into two modules. As results, it was proved that the proposed system could support three-dimensional post-processing service of medical images for multiple clients at the same moment, which met the demand of accessing three-dimensional post-processing operations on the volume data on the web.

  6. Three-dimensional reactor dynamics code for VVER type nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kyrki-Rajamaeki, R. [VTT Energy, Espoo (Finland)

    1995-10-01

    A three-dimensional reactor dynamics computer code has been developed, validated and applied for transient and accident analyses of VVER type nuclear reactors. This code, HEXTRAN, is a part of the reactor physics and dynamics calculation system of the Technical Research Centre of Finland, VTT. HEXTRAN models accurately the VVER core with hexagonal fuel assemblies. The code uses advanced mathematical methods in spatial and time discretization of neutronics, heat transfer and the two-phase flow equations of hydraulics. It includes all the experience of VTT from 20 years on the accurate three-dimensional static reactor physics as well as on the one-dimensional reactor dynamics. The dynamic coupling with the thermal hydraulic system code SMABRE also allows the VVER circuit-modelling experience to be included in the analyses. (79 refs.).

  7. Three-dimensional reactor dynamics code for VVER type nuclear reactors

    International Nuclear Information System (INIS)

    Kyrki-Rajamaeki, R.

    1995-10-01

    A three-dimensional reactor dynamics computer code has been developed, validated and applied for transient and accident analyses of VVER type nuclear reactors. This code, HEXTRAN, is a part of the reactor physics and dynamics calculation system of the Technical Research Centre of Finland, VTT. HEXTRAN models accurately the VVER core with hexagonal fuel assemblies. The code uses advanced mathematical methods in spatial and time discretization of neutronics, heat transfer and the two-phase flow equations of hydraulics. It includes all the experience of VTT from 20 years on the accurate three-dimensional static reactor physics as well as on the one-dimensional reactor dynamics. The dynamic coupling with the thermal hydraulic system code SMABRE also allows the VVER circuit-modelling experience to be included in the analyses. (79 refs.)

  8. Advanced numerical methods for three dimensional two-phase flow calculations

    Energy Technology Data Exchange (ETDEWEB)

    Toumi, I. [Laboratoire d`Etudes Thermiques des Reacteurs, Gif sur Yvette (France); Caruge, D. [Institut de Protection et de Surete Nucleaire, Fontenay aux Roses (France)

    1997-07-01

    This paper is devoted to new numerical methods developed for both one and three dimensional two-phase flow calculations. These methods are finite volume numerical methods and are based on the use of Approximate Riemann Solvers concepts to define convective fluxes versus mean cell quantities. The first part of the paper presents the numerical method for a one dimensional hyperbolic two-fluid model including differential terms as added mass and interface pressure. This numerical solution scheme makes use of the Riemann problem solution to define backward and forward differencing to approximate spatial derivatives. The construction of this approximate Riemann solver uses an extension of Roe`s method that has been successfully used to solve gas dynamic equations. As far as the two-fluid model is hyperbolic, this numerical method seems very efficient for the numerical solution of two-phase flow problems. The scheme was applied both to shock tube problems and to standard tests for two-fluid computer codes. The second part describes the numerical method in the three dimensional case. The authors discuss also some improvements performed to obtain a fully implicit solution method that provides fast running steady state calculations. Such a scheme is not implemented in a thermal-hydraulic computer code devoted to 3-D steady-state and transient computations. Some results obtained for Pressurised Water Reactors concerning upper plenum calculations and a steady state flow in the core with rod bow effect evaluation are presented. In practice these new numerical methods have proved to be stable on non staggered grids and capable of generating accurate non oscillating solutions for two-phase flow calculations.

  9. Advanced numerical methods for three dimensional two-phase flow calculations

    International Nuclear Information System (INIS)

    Toumi, I.; Caruge, D.

    1997-01-01

    This paper is devoted to new numerical methods developed for both one and three dimensional two-phase flow calculations. These methods are finite volume numerical methods and are based on the use of Approximate Riemann Solvers concepts to define convective fluxes versus mean cell quantities. The first part of the paper presents the numerical method for a one dimensional hyperbolic two-fluid model including differential terms as added mass and interface pressure. This numerical solution scheme makes use of the Riemann problem solution to define backward and forward differencing to approximate spatial derivatives. The construction of this approximate Riemann solver uses an extension of Roe's method that has been successfully used to solve gas dynamic equations. As far as the two-fluid model is hyperbolic, this numerical method seems very efficient for the numerical solution of two-phase flow problems. The scheme was applied both to shock tube problems and to standard tests for two-fluid computer codes. The second part describes the numerical method in the three dimensional case. The authors discuss also some improvements performed to obtain a fully implicit solution method that provides fast running steady state calculations. Such a scheme is not implemented in a thermal-hydraulic computer code devoted to 3-D steady-state and transient computations. Some results obtained for Pressurised Water Reactors concerning upper plenum calculations and a steady state flow in the core with rod bow effect evaluation are presented. In practice these new numerical methods have proved to be stable on non staggered grids and capable of generating accurate non oscillating solutions for two-phase flow calculations

  10. FLICA-4 (version 1). A computer code for three dimensional thermal analysis of nuclear reactor cores

    International Nuclear Information System (INIS)

    Raymond, P.; Allaire, G.; Boudsocq, G.; Caruge, D.; Gramont, T. de; Toumi, I.

    1995-01-01

    FLICA-4 is a thermal-hydraulic computer code, developed at the French Atomic Energy Commission (CEA) for three-dimensional steady-state or transient two-phase flow, and aimed at design and safety thermal analysis of nuclear reactor cores. It is available for various UNIX workstations and CRAY computers under UNICOS.It is based on four balance equations which include three balance equations for the mixture and a mass balance equation for the less concentrated phase which allows for the calculation of non equilibrium flows such as sub-cooled boiling and superheated steam. A drift velocity model takes into account the velocity unbalance between phases. The equations are solved using a finite volume numerical scheme. Typical running time, specific features (coupling with other codes) and auxiliary programs are presented. 1 tab., 9 refs

  11. An algorithm for three-dimensional imaging in the positron camera

    International Nuclear Information System (INIS)

    Chen Kun; Ma Mei; Xu Rongfen; Shen Miaohe

    1986-01-01

    A mathematical algorithm of back-projection filtered for image reconstructions using two-dimensional signals detected from parallel multiwire proportional chambers is described. The approaches of pseudo three-dimensional and full three-dimensional image reconstructions are introduced, and the available point response functions are defined as well. The designing parameters and computation procedure of the full three-dimensional method is presented

  12. Three-dimensional labeling program for elucidation of the geometric properties of biological particles in three-dimensional space.

    Science.gov (United States)

    Nomura, A; Yamazaki, Y; Tsuji, T; Kawasaki, Y; Tanaka, S

    1996-09-15

    For all biological particles such as cells or cellular organelles, there are three-dimensional coordinates representing the centroid or center of gravity. These coordinates and other numerical parameters such as volume, fluorescence intensity, surface area, and shape are referred to in this paper as geometric properties, which may provide critical information for the clarification of in situ mechanisms of molecular and cellular functions in living organisms. We have established a method for the elucidation of these properties, designated the three-dimensional labeling program (3DLP). Algorithms of 3DLP are so simple that this method can be carried out through the use of software combinations in image analysis on a personal computer. To evaluate 3DLP, it was applied to a 32-cell-stage sea urchin embryo, double stained with FITC for cellular protein of blastomeres and propidium iodide for nuclear DNA. A stack of optical serial section images was obtained by confocal laser scanning microscopy. The method was found effective for determining geometric properties and should prove applicable to the study of many different kinds of biological particles in three-dimensional space.

  13. Usefulness and capability of three-dimensional, full high-definition movies for surgical education.

    Science.gov (United States)

    Takano, M; Kasahara, K; Sugahara, K; Watanabe, A; Yoshida, S; Shibahara, T

    2017-12-01

    Because of changing surgical procedures in the fields of oral and maxillofacial surgery, new methods for surgical education are needed and could include recent advances in digital technology. Many doctors have attempted to use digital technology as educational tools for surgical training, and movies have played an important role in these attempts. We have been using a 3D full high-definition (full-HD) camcorder to record movies of intra-oral surgeries. The subjects were medical students and doctors receiving surgical training who did not have actual surgical experience ( n  = 67). Participants watched an 8-min, 2D movie of orthognathic surgery and subsequently watched the 3D version. After watching the 3D movie, participants were asked to complete a questionnaire. A lot of participants (84%) felt a 3D movie excellent or good and answered that the advantages of a 3D movie were their appearance of solidity or realism. Almost all participants (99%) answered that 3D movies were quite useful or useful for medical practice. Three-dimensional full-HD movies have the potential to improve the quality of medical education and clinical practice in oral and maxillofacial surgery.

  14. Three Dimensional Sheaf of Ultrasound Planes Reconstruction (SOUPR) of Ablated Volumes

    Science.gov (United States)

    Ingle, Atul; Varghese, Tomy

    2014-01-01

    This paper presents an algorithm for three dimensional reconstruction of tumor ablations using ultrasound shear wave imaging with electrode vibration elastography. Radiofrequency ultrasound data frames are acquired over imaging planes that form a subset of a sheaf of planes sharing a common axis of intersection. Shear wave velocity is estimated separately on each imaging plane using a piecewise linear function fitting technique with a fast optimization routine. An interpolation algorithm then computes velocity maps on a fine grid over a set of C-planes that are perpendicular to the axis of the sheaf. A full three dimensional rendering of the ablation can then be created from this stack of C-planes; hence the name “Sheaf Of Ultrasound Planes Reconstruction” or SOUPR. The algorithm is evaluated through numerical simulations and also using data acquired from a tissue mimicking phantom. Reconstruction quality is gauged using contrast and contrast-to-noise ratio measurements and changes in quality from using increasing number of planes in the sheaf are quantified. The highest contrast of 5 dB is seen between the stiffest and softest regions of the phantom. Under certain idealizing assumptions on the true shape of the ablation, good reconstruction quality while maintaining fast processing rate can be obtained with as few as 6 imaging planes suggesting that the method is suited for parsimonious data acquisitions with very few sparsely chosen imaging planes. PMID:24808405

  15. Three-Dimensional Photography for Quantitative Assessment of Penile Volume-Loss Deformities in Peyronie's Disease.

    Science.gov (United States)

    Margolin, Ezra J; Mlynarczyk, Carrie M; Mulhall, John P; Stember, Doron S; Stahl, Peter J

    2017-06-01

    Non-curvature penile deformities are prevalent and bothersome manifestations of Peyronie's disease (PD), but the quantitative metrics that are currently used to describe these deformities are inadequate and non-standardized, presenting a barrier to clinical research and patient care. To introduce erect penile volume (EPV) and percentage of erect penile volume loss (percent EPVL) as novel metrics that provide detailed quantitative information about non-curvature penile deformities and to study the feasibility and reliability of three-dimensional (3D) photography for measurement of quantitative penile parameters. We constructed seven penis models simulating deformities found in PD. The 3D photographs of each model were captured in triplicate by four observers using a 3D camera. Computer software was used to generate automated measurements of EPV, percent EPVL, penile length, minimum circumference, maximum circumference, and angle of curvature. The automated measurements were statistically compared with measurements obtained using water-displacement experiments, a tape measure, and a goniometer. Accuracy of 3D photography for average measurements of all parameters compared with manual measurements; inter-test, intra-observer, and inter-observer reliabilities of EPV and percent EPVL measurements as assessed by the intraclass correlation coefficient. The 3D images were captured in a median of 52 seconds (interquartile range = 45-61). On average, 3D photography was accurate to within 0.3% for measurement of penile length. It overestimated maximum and minimum circumferences by averages of 4.2% and 1.6%, respectively; overestimated EPV by an average of 7.1%; and underestimated percent EPVL by an average of 1.9%. All inter-test, inter-observer, and intra-observer intraclass correlation coefficients for EPV and percent EPVL measurements were greater than 0.75, reflective of excellent methodologic reliability. By providing highly descriptive and reliable measurements of

  16. Quantification of subarachnoid hemorrhage by three-dimensional computed tomography. Correlation between hematoma volume and symptomatic vasospasm

    International Nuclear Information System (INIS)

    Sato, Taku; Sakuma, Jun; Sasaki, Tatsuya

    2011-01-01

    Subarachnoid hemorrhage (SAH) volume was measured by three-dimensional computed tomography (3D-CT) and the correlation examined between the SAH volume and the occurrence of symptomatic vasospasm (SVS). Experimental (in vitro) hematomas were made with blood obtained from 10 volunteers. The hematoma volume was determined by actual measurements and by 3D-CT using a CT number in the range of 40-80 Hounsfield units (HU) on days 1, 4, 7, 11, and 14. The coefficients on days 1 and 4 were relatively high and the correlation between measured and estimated volumes was significant on days 7, 11, and 14. 3D-CT was also performed in 50 patients with SAH at onset (day 0) and on days 1, 4, 7, and 14. The hematoma volume including the volume of normal structures was automatically calculated (V1). The volume of normal structures (V2) with CT numbers of 40-80 HU was calculated in another 50 patients without intracranial lesions as 12 ml. The total hematoma volume was defined as V1 minus mean V2. The mean SAH volume was 44, 36, 21, 11, and 8 ml on days 0, 1, 4, 7, and 14, respectively. The hematoma volumes were significantly larger in patients with SVS than in patients without SVS at all time points. The minimum hematoma volume in patients with SVS was 92, 76, 42, 24, and 12 ml on days 0, 1, 4, 7, and 14, respectively. This method allows the quantitative determination of SAH volume based on 3D-CT, and may be useful in clinical studies of cerebral vasospasm. (author)

  17. Analysis of the one-dimensional transient compressible vapor flow in heat pipes

    Science.gov (United States)

    Jang, Jong H.; Faghri, Amir; Chang, Won S.

    1991-01-01

    The transient compressible one-dimensional vapor flow dynamics in a heat pipe is modeled. The numerical results are obtained by using the implicit non-iterative Beam-Warming finite difference method. The model is tested for simulated heat pipe vapor flow and actual vapor flow in cylindrical heat pipes. A good comparison of the present transient results for the simulated heat pipe vapor flow with the previous results of a two-dimensional numerical model is achieved and the steady state results are in agreement with the existing experimental data. The transient behavior of the vapor flow under subsonic, sonic, and supersonic speeds as well as high mass flow rates are successfully predicted.

  18. Multi-slice CT three dimensional volume measurement of tumors and livers in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Yu Yuanlong; Li Liangcai; Tang Binghang; Hu Zemin

    2004-01-01

    Objective: To examine the accuracy of multi-slice CT (MSCT) three dimensional (3D) volume measurement of tumors and livers in hepatocellular carcinoma cases by using immersion method as the standard. Methods: (1) The volume of 25 porkling livers was measured using immersion method in experiment group in vitro. Then the models were built according to Matsumoto's method and CT scanning and special software were used to measure the volume of the livers. (2) The volume of the tumors in 25 cases of hepatocellular carcinoma was measured using diameter measurement method and special volume measurement software (tissue measurements). Two tumors of them were measured respectively using MSCT 3D measurement, diameter measurement before the operation and immersion method after the operation. The data of the two groups were examined using pairing t test. Results: (1) The volume range of 25 porkling livers was 68.50-1150.10 ml using immersion method and 69.78-1069.97 ml using MSCT 3D measurement. There was no significant difference of the data in these two groups using t-test (t=1.427, P>0.05). (2) The volume range of 25 hepatocellular tumors was 395.16-2747.7 ml using diameter measurement and 203.10-1463.19 ml using MSCT 3D measurement before the operation. There was significant difference of the data in these two groups using t-test (t=7.689, P<0.001). In 2 ablated tumors, 1 case's volume was (21.75±0.60) ml using MSCT 3D measurement and 33.73 ml using diameter measurement before the operation and 21.50 ml using immersion measurement after the operation. The other case's volume was (696.13±5.30) ml using MSCT 3D measurement and 1323.51 ml using diameter measurement before the operation and 685.50 ml using immersion measurement after the operation. Conclusion: MSCT 3D volume measurement can accurately measure the volume of tumor and liver and has important clinical application value. There is no significant difference between MSCT 3D volume measurement and immersion method

  19. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    Energy Technology Data Exchange (ETDEWEB)

    You, Sung Hye; Son, Gyu Ri; Lee, Nam Joon [Dept. of Radiology, Korea University Anam Hospital, Seoul (Korea, Republic of); Suh, Sangil; Ryoo, In Seon; Seol, Hae Young [Dept. of Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, Young Hen; Seo, Hyung Suk [Dept. of Radiology, Korea University Ansan Hospital, Ansan (Korea, Republic of)

    2017-01-15

    The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism.

  20. Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method

    International Nuclear Information System (INIS)

    You, Sung Hye; Son, Gyu Ri; Lee, Nam Joon; Suh, Sangil; Ryoo, In Seon; Seol, Hae Young; Lee, Young Hen; Seo, Hyung Suk

    2017-01-01

    The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism

  1. Three-dimensional supersonic vortex breakdown

    Science.gov (United States)

    Kandil, Osama A.; Kandil, Hamdy A.; Liu, C. H.

    1993-01-01

    Three-dimensional supersonic vortex-breakdown problems in bound and unbound domains are solved. The solutions are obtained using the time-accurate integration of the unsteady, compressible, full Navier-Stokes (NS) equations. The computational scheme is an implicit, upwind, flux-difference splitting, finite-volume scheme. Two vortex-breakdown applications are considered in the present paper. The first is for a supersonic swirling jet which is issued from a nozzle into a supersonic uniform flow at a lower Mach number than that of the swirling jet. The second is for a supersonic swirling flow in a configured circular duct. In the first application, an extensive study of the effects of grid fineness, shape and grid-point distribution on the vortex breakdown is presented. Four grids are used in this study and they show a substantial dependence of the breakdown bubble and shock wave on the grid used. In the second application, the bubble-type and helix-type vortex breakdown have been captured.

  2. Three-dimensional evaluation of cartilage thickness and cartilage volume in the knee joint with MR imaging: reproducibility in volunteers

    International Nuclear Information System (INIS)

    Westhoff, J.; Eckstein, F.; Sittek, H.; Faber, S.; Reiser, M.; Loesch, A.; Englmeier, K.H.; Kolem, H.

    1997-01-01

    Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm 3 , using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% (±0.8%) in the patella, 1.7% (±1.5%) in the femur, 3.0% (±1.2%) in the medial tibial plateau and 3.5% (±2.0%) in the lateral tibial plateau. The comparison of the distribution patterns of cartilage thickness yielded a high degree of agreement. Only in rare cases deviations of more than 0.5 mm were observed. Conclusions: The results show that the presented method for determining the quantitative distribution of articular cartilage yields a high degree of precision. It offers new possibilities in screening risk groups, monitoring the course of degenerative joint disease and the investigation of functional adaptation of the cartilage to mechanical loading. (orig.) [de

  3. Geometry of lengths, areas, and volumes two-dimensional spaces, volume 1

    CERN Document Server

    Cannon, James W

    2017-01-01

    This is the first of a three volume collection devoted to the geometry, topology, and curvature of 2-dimensional spaces. The collection provides a guided tour through a wide range of topics by one of the twentieth century's masters of geometric topology. The books are accessible to college and graduate students and provide perspective and insight to mathematicians at all levels who are interested in geometry and topology. The first volume begins with length measurement as dominated by the Pythagorean Theorem (three proofs) with application to number theory; areas measured by slicing and scaling, where Archimedes uses the physical weights and balances to calculate spherical volume and is led to the invention of calculus; areas by cut and paste, leading to the Bolyai-Gerwien theorem on squaring polygons; areas by counting, leading to the theory of continued fractions, the efficient rational approximation of real numbers, and Minkowski's theorem on convex bodies; straight-edge and compass constructions, giving c...

  4. Three dimensional digital imaging of environmental data

    International Nuclear Information System (INIS)

    Nichols, R.L.; Eddy, C.A.

    1991-01-01

    The Environmental Sciences Section (ESS) of the Savannah River Laboratory has recently acquired the computer hardware (Silicon Graphics Personal Iris Workstations) and software (Dynamic Graphics, Interactive Surface and Volume Modeling) to perform three dimensional analysis of hydrogeologic data. Three dimensional digital imaging of environmental data is a powerful technique that can be used to incorporate field, analytical, and modeling results from geologic, hydrologic, ecologic, and chemical studies into a comprehensive model for visualization and interpretation. This report covers the contamination of four different sites of the Savannah River Plant. Each section of this report has a computer graphic display of the concentration of contamination in the groundwater and/or sediments of each site

  5. Transient effect of soil thermal diffusivity on performance of EATHE system

    OpenAIRE

    Mathur, Anuj; Srivastava, Ayushman; Mathur, Jyotirmay; Mathur, Sanjay; Agrawal, G.D.

    2015-01-01

    This paper presents effect of thermo-physical properties of soil on performance of an Earth Air Tunnel Heat Exchanger (EATHE). The analysis has been carried out using a validated three-dimensional, transient numerical model for three different types of soil. The governing equations, based on the k–ε model and energy equation were used to describe the turbulence and heat transfer phenomena, are solved by using finite volume method. Comparisons were made in terms of temperature drop, heat trans...

  6. Three-dimensional thermal hydraulic best estimate code BAGIRA: new results of verification

    International Nuclear Information System (INIS)

    Peter Kohut; Sergey D Kalinichenko; Alexander E Kroshilin; Vladimir E Kroshilin; Alexander V Smirnov

    2005-01-01

    Full text of publication follows: BAGIRA is a three-dimensional inhomogeneous two-velocity two-temperature thermal hydraulic code of best estimate, elaborated in VNIIAES for modeling two-phase flows in the primary circuit and steam generators of VVER-type nuclear reactors under various accident, transient or normal operation conditions. In this talk we present verification results of the BAGIRA code, obtained on the basis of different experiments performed on special and integral thermohydraulic experimental facilities as well as on real NPPs. Special attention is paid to the verification of three-dimensional flow models. Besides that we expose new results of the code benchmark analysis made on the basis of two recent LOCA-type experiments - 'Leak 2 x 25% from the hot leg double-side rupture' and 'Leak 3% from the cold leg' - performed on the PSB-VVER integral test facility (Electrogorsk Research and Engineering Center, Electrogorsk, Russia) - the most up-to-date Russian large-scale four-loop unit which has been designed for modelling the primary circuit of VVER-1000 type reactors. (authors)

  7. Coastwide Reference Monitoring System (CRMS) Vegetation Volume Index: An assessment tool for marsh habitat focused on the three-dimensional structure at CRMS vegetation monitoring stations

    Science.gov (United States)

    Wood, William B.; Visser, Jenneke M.; Piazza, Sarai C.; Sharp, Leigh A.; Hundy, Laura C.; McGinnis, Tommy E.

    2015-12-04

    A Vegetation Volume (VV) variable and Vegetation Volume Index (VVI) have been developed for the Coastwide Reference Monitoring System (CRMS). The VV is a measure of the amount of three-dimensional vegetative structure present at each CRMS site and is based on vegetation data collected annually. The VV uses 10 stations per CRMS site to quantify four vegetation layers: carpet, herbaceous, shrub, and tree. For each layer an overall live vegetation percent cover and height are collected to create a layer volume; the individual layer volumes are then summed to generate a site vegetation volume profile. The VV uses the two-dimensional area of live vegetative cover (in square meters) multiplied by the height (in meters) of each layer to produce a volume (in cubic meters) for each layer present in a 2-meter by 2-meter station. These layers are additive, yielding a total volume for each of the 10 herbaceous vegetation stations and an overall CRMS marsh site average.

  8. Variable thickness transient ground-water flow model. Volume 3. Program listings

    International Nuclear Information System (INIS)

    Reisenauer, A.E.

    1979-12-01

    The Assessment of Effectiveness of Geologic Isolation Systems (AEGIS) Program is developing and applying the methodology for assessing the far-field, long-term post-closure safety of deep geologic nuclear waste repositories. AEGIS is being performed by Pacific Northwest Laboratory (PNL) under contract with the Office of Nuclear Waste Isolation (OWNI) for the Department of Energy (DOE). One task within AEGIS is the development of methodology for analysis of the consequences (water pathway) from loss of repository containment as defined by various release scenarios. Analysis of the long-term, far-field consequences of release scenarios requires the application of numerical codes which simulate the hydrologic systems, model the transport of released radionuclides through the hydrologic systems to the biosphere, and, where applicable, assess the radiological dose to humans. Hydrologic and transport models are available at several levels of complexity or sophistication. Model selection and use are determined by the quantity and quality of input data. Model development under AEGIS and related programs provides three levels of hydrologic models, two levels of transport models, and one level of dose models (with several separate models). This is the third of 3 volumes of the description of the VTT (Variable Thickness Transient) Groundwater Hydrologic Model - second level (intermediate complexity) two-dimensional saturated groundwater flow

  9. Cylindrical Three-Dimensional Porous Anodic Alumina Networks

    Directory of Open Access Journals (Sweden)

    Pedro M. Resende

    2016-11-01

    Full Text Available The synthesis of a conformal three-dimensional nanostructure based on porous anodic alumina with transversal nanopores on wires is herein presented. The resulting three-dimensional network exhibits the same nanostructure as that obtained on planar geometries, but with a macroscopic cylindrical geometry. The morphological analysis of the nanostructure revealed the effects of the initial defects on the aluminum surface and the mechanical strains on the integrity of the three-dimensional network. The results evidence the feasibility of obtaining 3D porous anodic alumina on non-planar aluminum substrates.

  10. Impermeability effects in three-dimensional vesicles

    International Nuclear Information System (INIS)

    Biscari, P; Canevese, S M; Napoli, G

    2004-01-01

    We analyse the effects of the impermeability constraint on the equilibrium shapes of a three-dimensional vesicle hosting a rigid inclusion. A given alteration of the inclusion and/or vesicle parameters leads to shape modifications of different orders of magnitude, when applied to permeable or impermeable vesicles. Moreover, the enclosed-volume constraint wrecks the uniqueness of stationary equilibrium shapes, and gives rise to pear-shaped or stomatocyte-like vesicles

  11. SOLA-VOF, 2-D Transient Hydrodynamic Using Fractional Volume of Fluid Method

    International Nuclear Information System (INIS)

    Nichols, B.D.; Hirt, C.W.; Hotchkiss, R.S.

    1991-01-01

    1 - Description of problem or function: SOLA-VOF is a program for the solution of two-dimensional transient fluid flow with free boundaries, based on the concept of a fractional volume of fluid (VOF). Its basic mode of operation is for single fluid calculations having multiple free surfaces. However, SOLA-VOF can also be used for calculations involving two fluids separated by a sharp interface. In either case, the fluids may be treated as incompressible or as having limited compressibility. Surface tension forces with wall adhesion are permitted in both cases. Internal obstacles may be defined by blocking out any desired combination of cells in the mesh, which is composed of rectangular cells of variable size. 2 - Method of solution: The basis of the SOLA-VOF method is the fractional volume of fluid scheme for tracking free boundaries. In this technique, a function F(x,y,t) is defined whose value is unity at any point occupied by fluid and zero elsewhere. When averaged over the cells of a computational mesh, the average value of F in a cell is equal to the fractional volume of the cell occupied by fluid. In particular, a unit value of F corresponds to a cell full of fluid, whereas a zero value indicates that the cell contains no fluid. Cells with F values between zero and one contain a free surface. SOLA-VOF uses an Eulerian mesh of rectangular cells having variable sizes. The fluid equations solved are the finite difference approximations of the Navier-Stokes equations. 3 - Restrictions on the complexity of the problem: The setting of array dimensions is controlled through PARAMETER statements

  12. Three-dimensional imagery by encoding sources of X rays

    International Nuclear Information System (INIS)

    Magnin, Isabelle

    1987-01-01

    This research thesis addresses the theoretical and practical study of X ray coded sources, and thus notably aims at exploring whether it would be possible to transform a standard digital radiography apparatus (as those operated in radiology hospital departments) into a low cost three-dimensional imagery system. The author first recalls the principle of conventional tomography and improvement attempts, and describes imagery techniques based on the use of encoding openings and source encoding. She reports the modelling of an imagery system based on encoded sources of X ray, and addresses the original notion of three-dimensional response for such a system. The author then addresses the reconstruction method by considering the reconstruction of a plane object, of a multi-plane object, and of real three-dimensional object. The frequency properties and the tomographic capacities of various types of source codes are analysed. She describes a prototype tomography apparatus, and presents and discusses three-dimensional actual phantom reconstructions. She finally introduces a new principle of dynamic three-dimensional radiography which implements an acquisition technique by 'gating code'. The acquisition principle should allow the reconstruction of volumes animated by periodic deformations, such as the heart for example [fr

  13. The Three-dimensional Digital Factory for Shipbuilding Technology Research

    Directory of Open Access Journals (Sweden)

    Xu Wei

    2016-01-01

    Full Text Available The three-dimensional digital factory technology research is the hotspot in shipbuilding recently. The three-dimensional digital factory technology not only focus on design the components of the product, but also discuss on the simulation and analyses of the production process.Based on the three-dimensional model, the basic data layer, application control layer and the presentation layer of hierarchical structure are established in the three-dimensional digital factory of shipbuilding in this paper. And the key technologies of three-dimensional digital factory of shipbuilding are analysed. Finally, a case study is applied and the results show that the three-dimensional digital factory will play an important role in the future.

  14. Sonocubic fine: new three-dimensional ultrasound software to the screening of congenital heart diseases

    Directory of Open Access Journals (Sweden)

    Edward Araujo Júnior

    2014-09-01

    Full Text Available Congenital heart disease is the most common fetal congenital malformations; however, the prenatal rate detection still is low. The two-dimensional echocardiography is the "gold standard" exam to screening and diagnosis of congenital heart disease during the prenatal; however, this exam is operator-depending and it is realized only in high risk pregnancies. Spatio-temporal image correlation is a three-dimensional ultrasound software that analyses the fetal heart and your connections in the multiplanar and rendering modes; however, spatio-temporal image correlation too is operator-depending and time-consuming. We presenting a new three-dimensional software named Sonocubic fine to the screening of congenital heart disease. This software applies intelligent navigation technology to spatio-temporal image correlation volume datasets to automatically generate nine fetal echocardiography standard views. Thus, this new software tends to be less operator-depending and time-consuming.

  15. Analytical Modeling of Transient Process In Terms of One-Dimensional Problem of Dynamics With Kinematic Action

    Directory of Open Access Journals (Sweden)

    Kravets Victor V.

    2016-05-01

    Full Text Available One-dimensional dynamic design of a component characterized by inertia coefficient, elastic coefficient, and coefficient of energy dispersion. The component is affected by external action in the form of time-independent initial kinematic disturbances and varying ones. Mathematical model of component dynamics as well as a new form of analytical representation of transient in terms of one-dimensional problem of kinematic effect is provided. Dynamic design of a component is being carried out according to a theory of modal control.

  16. Three-dimensional reconstruction of colorectal tumors from serial tissue sections by computer graphics: a preliminary study.

    Science.gov (United States)

    Kikuchi, S; Matsuzaki, H; Kondo, K; Ohtani, Y; Ihara, A; Hiki, Y; Kakita, A; Kuwao, S

    2000-01-01

    We present herein the three-dimensional reconstruction of colorectal tumors, with particular reference to growth pattern into each layer of the colorectal wall, and measurement of tumor volume and surface area. Conventional tissue section images of colorectal tumors were analyzed using a computer graphics analysis program. The two-dimensional extent of invasion by each tumor into each layer of intestinal wall were determined from the images of each section. Based on data from multiple sections, tumor and surrounding normal tissue layers were reconstructed three-dimensionally, and volume and surface area of the tumors were determined. Using this technique, three-dimensional morphology of tumor and tumor progression into colorectal wall could be determined. Volume and surface area of the colon tumor were 4871 mm3 and 1741 mm2, respectively. Volume and surface area of the rectal tumor were 1090 mm3 and 877 mm2, respectively. This technique may provide a new approach for pathological analysis of colorectal carcinoma.

  17. Analysis of Operating Performance and Three Dimensional Magnetic Field of High Voltage Induction Motors with Stator Chute

    Directory of Open Access Journals (Sweden)

    WANG Qing-shan

    2017-06-01

    Full Text Available In view of the difficulties on technology of rotor chute in high voltage induction motor,the desig method adopted stator chute structure is put forward. The mathematical model of three dimensional nonlinear transient field for solving stator chute in high voltage induction motor is set up. Through the three dimensional entity model of motor,three dimensional finite element method based on T,ψ - ψ electromagnetic potential is adopted for the analysis and calculation of stator chute in high voltage induction motor under rated condition. The distributions long axial of fundamental wave magnetic field and tooth harmonic wave magnetic field are analyzed after stator chute,and the weakening effects on main tooth harmonic magnetic field are researched. Further more,the comparison analysis of main performance parameters of chute and straight slot is carried out under rated condition. The results show that the electrical performance of stator chute is better than that of straight slot in high voltage induction motor,and the tooth harmonic has been sharply decreased

  18. Development of a system for acquiring, reconstructing, and visualizing three-dimensional ultrasonic angiograms

    Science.gov (United States)

    Edwards, Warren S.; Ritchie, Cameron J.; Kim, Yongmin; Mack, Laurence A.

    1995-04-01

    We have developed a three-dimensional (3D) imaging system using power Doppler (PD) ultrasound (US). This system can be used for visualizing and analyzing the vascular anatomy of parenchymal organs. To create the 3D PD images, we acquired a series of two-dimensional PD images from a commercial US scanner and recorded the position and orientation of each image using a 3D magnetic position sensor. Three-dimensional volumes were reconstructed using specially designed software and then volume rendered for display. We assessed the feasibility and geometric accuracy of our system with various flow phantoms. The system was then tested on a volunteer by scanning a transplanted kidney. The reconstructed volumes of the flow phantom contained less than 1 mm of geometric distortion and the 3D images of the transplanted kidney depicted the segmental, arcuate, and interlobar vessels.

  19. A Three-Dimensional, Immersed Boundary, Finite Volume Method for the Simulation of Incompressible Heat Transfer Flows around Complex Geometries

    Directory of Open Access Journals (Sweden)

    Hassan Badreddine

    2017-01-01

    Full Text Available The current work focuses on the development and application of a new finite volume immersed boundary method (IBM to simulate three-dimensional fluid flows and heat transfer around complex geometries. First, the discretization of the governing equations based on the second-order finite volume method on Cartesian, structured, staggered grid is outlined, followed by the description of modifications which have to be applied to the discretized system once a body is immersed into the grid. To validate the new approach, the heat conduction equation with a source term is solved inside a cavity with an immersed body. The approach is then tested for a natural convection flow in a square cavity with and without circular cylinder for different Rayleigh numbers. The results computed with the present approach compare very well with the benchmark solutions. As a next step in the validation procedure, the method is tested for Direct Numerical Simulation (DNS of a turbulent flow around a surface-mounted matrix of cubes. The results computed with the present method compare very well with Laser Doppler Anemometry (LDA measurements of the same case, showing that the method can be used for scale-resolving simulations of turbulence as well.

  20. Toxicity and cosmetic outcome of three-dimensional conformal radiotherapy for accelerated partial breast irradiation

    International Nuclear Information System (INIS)

    Gatti, M.; Bresciani, S.; Ponzone, R.; Panaia, R.; Salatino, A.; Stasi, M.; Gabriele, P.

    2011-01-01

    Full text of publication follows: Purpose.- To analyse the incidence and severity of acute and late normal tissue toxicity and cosmetic outcome using three - dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Patients and Methods.- 70 patients with stage I disease were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation, in an approved protocol. The prescribed dose was 34 Gy in all patients delivered in 10 fractions over 5 consecutive days. On all CT scans gross tumor volume (GTV ) was defined around surgical clips. A 1.5 cm margin was added in order to account for clinical target volume (CTV) . A margin of 1 cm was added to CTI to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the specifications as dictated in the NSABP/RTOG protocol. After treatment, patients underwent a clinical and cosmetic evaluation every 3 months. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed by the physicians using the controlateral untreated breast as the reference (Harvard scale). Results.- Median patient age was 66 years (range 51-80). Median follow-up was 15 months (range 6-46). Tumor size was 2 cm in 4(6%). The mean value of the ratio between the PTV and the whole ipsilateral breast volume was 38 % and the median percentage whole breast volume that received 95 % of prescribed dose was 34% (range 16%-55%). The rate of G1 and G2 acute skin toxicity was 28% and 2% respectively and the late toxicity was 17% (G1). G2 or greater toxicities were not observed. The most pronounced G1 late toxicity was subcutaneous fibrosis, developed in 3 patients. The cosmetic outcome was excellent in 83% and good in 17%. Conclusion.- Accelerated partial breast irradiation using three-dimensional conformal radiotherapy is technically feasible with very low acute and late toxicity. Long-term results are needed to assess

  1. Three-Dimensional Eyeball and Orbit Volume Modification After LeFort III Midface Distraction.

    Science.gov (United States)

    Smektala, Tomasz; Nysjö, Johan; Thor, Andreas; Homik, Aleksandra; Sporniak-Tutak, Katarzyna; Safranow, Krzysztof; Dowgierd, Krzysztof; Olszewski, Raphael

    2015-07-01

    The aim of our study was to evaluate orbital volume modification with LeFort III midface distraction in patients with craniosynostosis and its influence on eyeball volume and axial diameter modification. Orbital volume was assessed by the semiautomatic segmentation method based on deformable surface models and on 3-dimensional (3D) interaction with haptics. The eyeball volumes and diameters were automatically calculated after manual segmentation of computed tomographic scans with 3D slicer software. The mean, minimal, and maximal differences as well as the standard deviation and intraclass correlation coefficient (ICC) for intraobserver and interobserver measurements reliability were calculated. The Wilcoxon signed rank test was used to compare measured values before and after surgery. P eyeball volume were 0.87 and 0.86, respectively. The orbital volume increased significantly after surgery: 30.32% (mean, 5.96  mL) for the left orbit and 31.04% (mean, 6.31  mL) for the right orbit. The mean increase in eyeball volume was 12.3%. The mean increases in the eyeball axial dimensions were 7.3%, 9.3%, and 4.4% for the X-, Y-, and Z-axes, respectively. The Wilcoxon signed rank test showed that preoperative and postoperative eyeball volumes, as well as the diameters along the X- and Y-axes, were statistically significant. Midface distraction in patients with syndromic craniostenosis results in a significant increase (P eyeball volumes. The 2 methods (haptic-aided semiautomatic segmentation and manual 3D slicer segmentation) are reproducible techniques for orbit and eyeball volume measurements.

  2. TITAN: an advanced three-dimensional neutronics/thermal-hydraulics code for light water reactor safety analysis

    International Nuclear Information System (INIS)

    Griggs, D.P.; Kazimi, M.S.; Henry, A.F.

    1982-01-01

    The initial development of TITAN, a three-dimensional coupled neutronics/thermal-hydraulics code for LWR safety analysis, has been completed. The transient neutronics code QUANDRY has been joined to the two-fluid thermal-hydraulics code THERMIT with the appropriate feedback mechanisms modeled. A detailed steady-state and transient coupling scheme based on the tandem technique was implemented in accordance with the important structural and operational characteristics of QUANDRY and THERMIT. A two channel sample problem formed the basis for steady-state and transient analyses performed with TITAN. TITAN steady-state results were compared with those obtained with MEKIN and showed good agreement. Null transients, simulated turbine trip transients, and a rod withdrawal transient were analyzed with TITAN and reasonable results were obtained

  3. Non-Euclidean geometry and curvature two-dimensional spaces, volume 3

    CERN Document Server

    Cannon, James W

    2017-01-01

    This is the final volume of a three volume collection devoted to the geometry, topology, and curvature of 2-dimensional spaces. The collection provides a guided tour through a wide range of topics by one of the twentieth century's masters of geometric topology. The books are accessible to college and graduate students and provide perspective and insight to mathematicians at all levels who are interested in geometry and topology. Einstein showed how to interpret gravity as the dynamic response to the curvature of space-time. Bill Thurston showed us that non-Euclidean geometries and curvature are essential to the understanding of low-dimensional spaces. This third and final volume aims to give the reader a firm intuitive understanding of these concepts in dimension 2. The volume first demonstrates a number of the most important properties of non-Euclidean geometry by means of simple infinite graphs that approximate that geometry. This is followed by a long chapter taken from lectures the author gave at MSRI, wh...

  4. Three-dimensional theory for light-matter interaction

    DEFF Research Database (Denmark)

    Sørensen, Martin Westring; Sørensen, Anders Søndberg

    2008-01-01

    We present a full quantum mechanical three dimensional theory describing an electromagnetic field interacting with an ensemble of identical atoms. The theory is constructed such that it describes recent experiments on light-matter quantum interfaces, where the quantum fluctuations of light...... to a dressed state picture, where the light modes are solutions to the diffraction problem, and develop a perturbative expansion in the fluctuations. The fluctuations are due to quantum fluctuations as well as the random positions of the atoms. In this perturbative expansion we show how the quantum...... fluctuations are mapped between atoms and light while the random positioning of the atoms give rise to decay due to spontaneous emission. Furthermore we identify limits, where the full three dimensional theory reduce to the one dimensional theory typically used to describe the interaction....

  5. TITAN: an advanced three-dimensional coupled neutronic/thermal-hydraulics code for light water nuclear reactor core analysis

    International Nuclear Information System (INIS)

    Griggs, D.P.; Kazimi, M.S.; Henry, A.F.

    1984-06-01

    The three-dimensional nodal neutronics code QUANDRY and the three-dimensional two-fluid thermal-hydraulics code THERMIT are combined into TITAN. Steady-state and transient coupling methodologies based upon a tandem structure were devised and implemented. Additional models for nuclear feedback, equilibrium xenon and direct moderator heating were added. TITAN was tested using a boiling water two channel problem and the coupling methodologies were shown to be effective. Simulated turbine trip transients and several control rod withdrawal transients were analyzed with good results. Sensitivity studies indicated that the time-step size can affect transient results significantly. TITAN was also applied to a quarter core PWR problem based on a real reactor geometry. The steady-state results were compared to a solution produced by MEKIN-B and poor agreement between the horizontal power shapes was found. Calculations with various mesh spacings showed that the mesh spacings in the MEKIN-B analysis were too large to produce accurate results with a finite difference method. The TITAN results were shown to be reasonable. A pair of control rod ejection accidents were also analyzed with TITAN. A comparison of the TITAN PWR control rod ejection results with results from coupled point kinetics/thermal-hydraulics analyses showed that the point kinetics method used (adiabatic method for control rod reactivities, steady-state flux shape for core-averaged reactivity feedback) underpredicted the power excursion in one case and overpredicted it in the other. It was therefore concluded that point kinetics methods should be used with caution and that three-dimensional codes like TITAN are superior for analyzing PWR control rod ejection transients

  6. Influence of using a single facial vein as outflow in full-face transplantation: A three-dimensional computed tomographic study.

    Science.gov (United States)

    Rodriguez-Lorenzo, Andres; Audolfsson, Thorir; Wong, Corrine; Cheng, Angela; Arbique, Gary; Nowinski, Daniel; Rozen, Shai

    2015-10-01

    The aim of this study was to evaluate the contribution of a single unilateral facial vein in the venous outflow of total-face allograft using three-dimensional computed tomographic imaging techniques to further elucidate the mechanisms of venous complications following total-face transplant. Full-face soft-tissue flaps were harvested from fresh adult human cadavers. A single facial vein was identified and injected distally to the submandibular gland with a radiopaque contrast (barium sulfate/gelatin mixture) in every specimen. Following vascular injections, three-dimensional computed tomographic venographies of the faces were performed. Images were viewed using TeraRecon Software (Teracon, Inc., San Mateo, CA, USA) allowing analysis of the venous anatomy and perfusion in different facial subunits by observing radiopaque filling venous patterns. Three-dimensional computed tomographic venographies demonstrated a venous network with different degrees of perfusion in subunits of the face in relation to the facial vein injection side: 100% of ipsilateral and contralateral forehead units, 100% of ipsilateral and 75% of contralateral periorbital units, 100% of ipsilateral and 25% of contralateral cheek units, 100% of ipsilateral and 75% of contralateral nose units, 100% of ipsilateral and 75% of contralateral upper lip units, 100% of ipsilateral and 25% of contralateral lower lip units, and 50% of ipsilateral and 25% of contralateral chin units. Venographies of the full-face grafts revealed better perfusion in the ipsilateral hemifaces from the facial vein in comparison with the contralateral hemifaces. Reduced perfusion was observed mostly in the contralateral cheek unit and contralateral lower face including the lower lip and chin units. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Theory and application of a three-dimensional code SHAPS to complex piping systems

    International Nuclear Information System (INIS)

    Wang, C.Y.

    1983-01-01

    This paper describes the theory and application of a three-dimensional computer code SHAPS to the complex piping systems. The code utilizes a two-dimensional implicit Eulerian method for the hydrodynamic analysis together with a three-dimensional elastic-plastic finite-element program for the structural calculation. A three-dimensional pipe element with eight degrees of freedom is employed to account for the hoop, flexural, axial, and the torsional mode of the piping system. In the SHAPS analysis the hydrodynamic equations are modified to include the global piping motion. Coupling between fluid and structure is achieved by enforcing the free-slip boundary conditions. Also, the response of the piping network generated by the seismic excitation can be included. A thermal transient capability is also provided in SHAPS. To illustrate the methodology, many sample problems dealing with the hydrodynamic, structural, and thermal analyses of reactor-piping systems are given. Validation of the SHAPS code with experimental data is also presented

  8. On the size distribution of one-, two- and three-dimensional Voronoi cells

    International Nuclear Information System (INIS)

    Marthinsen, K.

    1994-03-01

    The present report gives a presentation of the different cell size distribution obtained by computer simulations of random Voronoi cell structures in one-, two- and three-dimensional space. The random Voronoi cells are constructed from cell centroids randomly distributed along a string, in the plane and in three-dimensional space, respectively. The size distributions are based on 2-3 · 10 4 cells. For the spacial polyhedra both the distribution of volumes, areas and radii are presented, and the two latter quantities are compared to the distributions of areas and radii from a planar section through the three-dimensional structure as well as to the corresponding distributions obtained from a pure two-dimensional cell structure. 11 refs., 11 figs

  9. Research and Realization of Medical Image Fusion Based on Three-Dimensional Reconstruction

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    A new medical image fusion technique is presented. The method is based on three-dimensional reconstruction. After reconstruction, the three-dimensional volume data is normalized by three-dimensional coordinate conversion in the same way and intercepted through setting up cutting plane including anatomical structure, as a result two images in entire registration on space and geometry are obtained and the images are fused at last.Compared with traditional two-dimensional fusion technique, three-dimensional fusion technique can not only resolve the different problems existed in the two kinds of images, but also avoid the registration error of the two kinds of images when they have different scan and imaging parameter. The research proves this fusion technique is more exact and has no registration, so it is more adapt to arbitrary medical image fusion with different equipments.

  10. Three-dimensional volumetric gray-scale uterine cervix histogram prediction of days to delivery in full term pregnancy.

    Science.gov (United States)

    Kim, Ji Youn; Kim, Hai-Joong; Hahn, Meong Hi; Jeon, Hye Jin; Cho, Geum Joon; Hong, Sun Chul; Oh, Min Jeong

    2013-09-01

    Our aim was to figure out whether volumetric gray-scale histogram difference between anterior and posterior cervix can indicate the extent of cervical consistency. We collected data of 95 patients who were appropriate for vaginal delivery with 36th to 37th weeks of gestational age from September 2010 to October 2011 in the Department of Obstetrics and Gynecology, Korea University Ansan Hospital. Patients were excluded who had one of the followings: Cesarean section, labor induction, premature rupture of membrane. Thirty-four patients were finally enrolled. The patients underwent evaluation of the cervix through Bishop score, cervical length, cervical volume, three-dimensional (3D) cervical volumetric gray-scale histogram. The interval days from the cervix evaluation to the delivery day were counted. We compared to 3D cervical volumetric gray-scale histogram, Bishop score, cervical length, cervical volume with interval days from the evaluation of the cervix to the delivery. Gray-scale histogram difference between anterior and posterior cervix was significantly correlated to days to delivery. Its correlation coefficient (R) was 0.500 (P = 0.003). The cervical length was significantly related to the days to delivery. The correlation coefficient (R) and P-value between them were 0.421 and 0.013. However, anterior lip histogram, posterior lip histogram, total cervical volume, Bishop score were not associated with days to delivery (P >0.05). By using gray-scale histogram difference between anterior and posterior cervix and cervical length correlated with the days to delivery. These methods can be utilized to better help predict a cervical consistency.

  11. TRIPOLI I: energy-dependent three-dimensional Monte Carlo Program. Volume I. Conception and presentation of the TRIPOLI I System

    International Nuclear Information System (INIS)

    Katz, S.; Nimal, J.C.

    In its present version TRIPOLI/1/ is an energy dependent three-dimensional program which treats the slowing down and diffusion of neutrons for source problems. The version presented here is essentially oriented towards reactor shielding problems. It is written in FORTRAN for IBM (series 360) computer. This volume is devoted to a summary of the essential characteristics of the program as well as to a description of the constants required for the description of the chaining together of the work to be carried out

  12. Finite volume gauge theory partition functions in three dimensions

    International Nuclear Information System (INIS)

    Szabo, Richard J.

    2005-01-01

    We determine the fermion mass dependence of Euclidean finite volume partition functions for three-dimensional QCD in the ε-regime directly from the effective field theory of the pseudo-Goldstone modes by using zero-dimensional non-linear σ-models. New results are given for an arbitrary number of flavours in all three cases of complex, pseudo-real and real fermions, extending some previous considerations based on random matrix theory. They are used to describe the microscopic spectral correlation functions and smallest eigenvalue distributions of the QCD 3 Dirac operator, as well as the corresponding massive spectral sum rules

  13. Multi-dimensional Analysis for SLB Transient in ATLAS Facility as Activity of DSP (Domestic Standard Problem)

    International Nuclear Information System (INIS)

    Bae, B. U.; Park, Y. S.; Kim, J. R.; Kang, K. H.; Choi, K. Y.; Sung, H. J.; Hwang, M. J.; Kang, D. H.; Lim, S. G.; Jun, S. S.

    2015-01-01

    Participants of DSP-03 were divided in three groups and each group has focused on the specific subject related to the enhancement of the code analysis. The group A tried to investigate scaling capability of ATLAS test data by comparing to the code analysis for a prototype, and the group C studied to investigate effect of various models in the one-dimensional codes. This paper briefly summarizes the code analysis result from the group B participants in the DSP-03 of the ATLAS test facility. The code analysis by Group B focuses highly on investigating the multi-dimensional thermal hydraulic phenomena in the ATLAS facility during the SLB transient. Even though the one-dimensional system analysis code cannot simulate the whole system of the ATLAS facility with a nodalization of the CFD (Computational Fluid Dynamics) scale, a reactor pressure vessel can be considered with multi-dimensional components to reflect the thermal mixing phenomena inside a downcomer and a core. Also, the CFD could give useful information for understanding complex phenomena in specific components such as the reactor pressure vessel. From the analysis activity of Group B in ATLAS DSP-03, participants adopted a multi-dimensional approach to the code analysis for the SLB transient in the ATLAS test facility. The main purpose of the analysis was to investigate prediction capability of multi-dimensional analysis tools for the SLB experiment result. In particular, the asymmetric cooling and thermal mixing phenomena in the reactor pressure vessel could be significantly focused for modeling the multi-dimensional components

  14. Three-dimensional single-mode nonlinear ablative Rayleigh-Taylor instability

    International Nuclear Information System (INIS)

    Yan, R.; Aluie, H.; Betti, R.; Sanz, J.; Liu, B.; Frank, A.

    2016-01-01

    The nonlinear evolution of the single-mode ablative Rayleigh-Taylor instability is studied in three dimensions. As the mode wavelength approaches the cutoff of the linear spectrum (short-wavelength modes), it is found that the three-dimensional (3D) terminal bubble velocity greatly exceeds both the two-dimensional (2D) value and the classical 3D bubble velocity. Unlike in 2D, the 3D short-wavelength bubble velocity does not saturate. The growing 3D bubble acceleration is driven by the unbounded accumulation of vorticity inside the bubble. The vorticity is transferred by mass ablation from the Rayleigh-Taylor spikes to the ablated plasma filling the bubble volume

  15. Strategy for solving semi-analytically three-dimensional transient flow in a coupled N-layer aquifer system

    NARCIS (Netherlands)

    Veling, E.J.M.; Maas, C.

    2008-01-01

    Efficient strategies for solving semi-analytically the transient groundwater head in a coupled N-layer aquifer system phi(i)(r, z, t), i = 1, ..., N, with radial symmetry, with full z-dependency, and partially penetrating wells are presented. Aquitards are treated as aquifers with their own

  16. Three-dimensional ICT reconstruction

    International Nuclear Information System (INIS)

    Zhang Aidong; Li Ju; Chen Fa; Sun Lingxia

    2005-01-01

    The three-dimensional ICT reconstruction method is the hot topic of recent ICT technology research. In the context, qualified visual three-dimensional ICT pictures are achieved through multi-piece two-dimensional images accumulation by, combining with thresholding method and linear interpolation. Different direction and different position images of the reconstructed pictures are got by rotation and interception respectively. The convenient and quick method is significantly instructive to more complicated three-dimensional reconstruction of ICT images. (authors)

  17. Three-dimensional ICT reconstruction

    International Nuclear Information System (INIS)

    Zhang Aidong; Li Ju; Chen Fa; Sun Lingxia

    2004-01-01

    The three-dimensional ICT reconstruction method is the hot topic of recent ICT technology research. In the context qualified visual three-dimensional ICT pictures are achieved through multi-piece two-dimensional images accumulation by order, combining with thresholding method and linear interpolation. Different direction and different position images of the reconstructed pictures are got by rotation and interception respectively. The convenient and quick method is significantly instructive to more complicated three-dimensional reconstruction of ICT images. (authors)

  18. Gyrokinetic Vlasov code including full three-dimensional geometry of experiments

    International Nuclear Information System (INIS)

    Nunami, Masanori; Watanabe, Tomohiko; Sugama, Hideo

    2010-03-01

    A new gyrokinetic Vlasov simulation code, GKV-X, is developed for investigating the turbulent transport in magnetic confinement devices with non-axisymmetric configurations. Effects of the magnetic surface shapes in a three-dimensional equilibrium obtained from the VMEC code are accurately incorporated. Linear simulations of the ion temperature gradient instabilities and the zonal flows in the Large Helical Device (LHD) configuration are carried out by the GKV-X code for a benchmark test against the GKV code. The frequency, the growth rate, and the mode structure of the ion temperature gradient instability are influenced by the VMEC geometrical data such as the metric tensor components of the Boozer coordinates for high poloidal wave numbers, while the difference between the zonal flow responses obtained by the GKV and GKV-X codes is found to be small in the core LHD region. (author)

  19. Volume Tracking: A new method for quantitative assessment and visualization of intracardiac blood flow from three-dimensional, time-resolved, three-component magnetic resonance velocity mapping

    International Nuclear Information System (INIS)

    Töger, Johannes; Carlsson, Marcus; Söderlind, Gustaf; Arheden, Håkan; Heiberg, Einar

    2011-01-01

    Functional and morphological changes of the heart influence blood flow patterns. Therefore, flow patterns may carry diagnostic and prognostic information. Three-dimensional, time-resolved, three-directional phase contrast cardiovascular magnetic resonance (4D PC-CMR) can image flow patterns with unique detail, and using new flow visualization methods may lead to new insights. The aim of this study is to present and validate a novel visualization method with a quantitative potential for blood flow from 4D PC-CMR, called Volume Tracking, and investigate if Volume Tracking complements particle tracing, the most common visualization method used today. Eight healthy volunteers and one patient with a large apical left ventricular aneurysm underwent 4D PC-CMR flow imaging of the whole heart. Volume Tracking and particle tracing visualizations were compared visually side-by-side in a visualization software package. To validate Volume Tracking, the number of particle traces that agreed with the Volume Tracking visualizations was counted and expressed as a percentage of total released particles in mid-diastole and end-diastole respectively. Two independent observers described blood flow patterns in the left ventricle using Volume Tracking visualizations. Volume Tracking was feasible in all eight healthy volunteers and in the patient. Visually, Volume Tracking and particle tracing are complementary methods, showing different aspects of the flow. When validated against particle tracing, on average 90.5% and 87.8% of the particles agreed with the Volume Tracking surface in mid-diastole and end-diastole respectively. Inflow patterns in the left ventricle varied between the subjects, with excellent agreement between observers. The left ventricular inflow pattern in the patient differed from the healthy subjects. Volume Tracking is a new visualization method for blood flow measured by 4D PC-CMR. Volume Tracking complements and provides incremental information compared to particle

  20. Three-dimensional analysis of craniofacial bones using three-dimensional computer tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Ichiro; Ohura, Takehiko; Kimura, Chu (Hokkaido Univ., Sapporo (Japan). School of Medicine) (and others)

    1989-08-01

    Three-dimensional computer tomography (3DCT) was performed in patients with various diseases to visualize stereoscopically the deformity of the craniofacial bones. The data obtained were analyzed by the 3DCT analyzing system. A new coordinate system was established using the median sagittal plane of the face (a plane passing through sella, nasion and basion) on the three-dimensional image. Three-dimensional profilograms were prepared for detailed analysis of the deformation of craniofacial bones for cleft lip and palate, mandibular prognathia and hemifacial microsomia. For patients, asymmetry in the frontal view and twist-formed complicated deformities were observed, as well as deformity of profiles in the anteroposterior and up-and-down directions. A newly developed technique allows three-dimensional visualization of changes in craniofacial deformity. It would aid in determining surgical strategy, including crani-facial surgery and maxillo-facial surgery, and in evaluating surgical outcome. (N.K.).

  1. Three-dimensional analysis of craniofacial bones using three-dimensional computer tomography

    International Nuclear Information System (INIS)

    Ono, Ichiro; Ohura, Takehiko; Kimura, Chu

    1989-01-01

    Three-dimensional computer tomography (3DCT) was performed in patients with various diseases to visualize stereoscopically the deformity of the craniofacial bones. The data obtained were analyzed by the 3DCT analyzing system. A new coordinate system was established using the median sagittal plane of the face (a plane passing through sella, nasion and basion) on the three-dimensional image. Three-dimensional profilograms were prepared for detailed analysis of the deformation of craniofacial bones for cleft lip and palate, mandibular prognathia and hemifacial microsomia. For patients, asymmetry in the frontal view and twist-formed complicated deformities were observed, as well as deformity of profiles in the anteroposterior and up-and-down directions. A newly developed technique allows three-dimensional visualization of changes in craniofacial deformity. It would aid in determining surgical strategy, including crani-facial surgery and maxillo-facial surgery, and in evaluating surgical outcome. (N.K.)

  2. Investigation on the Yarn Squeezing Effect of Three Dimensional Full Five Directional Braided Composites

    Science.gov (United States)

    Hu, Long; Tao, Guoquan; Liu, Zhenguo; Wang, Yibo; Ya, Jixuan

    2018-04-01

    The influence of yarn squeezing effect on the geometric morphology and mechanical property of the three dimensional full five directional (3DF5D) braided composites is explored. Spatial path and cross-section shape of the yarns in the braided structure are characterized based on the micro computed tomography (micro CT) scanning images. The yarn distortion due to the squeezing effect is discussed and mathematical morphology of the yarn geometry is established. A new repeated unit cell (RUC) model of 3DF5D braided composites considering yarn squeezing effect is developed. Based on this model, mechanical properties of 3DF5D braided composites are analyzed. Good agreement is obtained between the predicted and experiment results. Moreover, the stress distribution of the new RUC model are compared with original RUC model, showing that the squeezing effect significantly increases the stress concentration level of the axial yarns.

  3. Three-dimensional temperature history of a multipass filled weldment. Part 2

    International Nuclear Information System (INIS)

    Pinkowish, J.A.; Whitman, P.K.

    1976-01-01

    Computer simulation of the three-dimensional temperature history in a multipass filled weldment was attempted by modifying a transient heat transfer code, HEATING5. The model includes temperature-dependent physical parameters, radiation and convection heat losses, turbulent and laminar convection in the molten pool, and variable arc velocity, intensity, and weld geometry. The model requires approximately 28 CPU min to simulate one second of welding. 15 figures, 8 tables

  4. The value of 18F-FDG PET in three-dimensional conformal radiotherapy of cancer

    International Nuclear Information System (INIS)

    Lv Huiqing; Zhang Zhongmin; Lv Zhonghong

    2006-01-01

    Three-dimensional conformal radiotherapy (3D-CRT) is based on an extensive use of modern medical imaging techniques. Delineation of the gross tumor volume and organs at risk constitutes one of the most important phases of conformal radiotherapy procedures. 18 F-fluorodeoxyglucose ( 18 F-FDG) PET possesses greater sensitivity and accuracy in detecting diseased lymph nodes, is an important staging examination for patients considered for radiation treatment with curative intent. 18 F-FDG PET has an important role in delineation of gross tumor volume for patients treated with three-dimensional conformal radiotherapy. (authors)

  5. RAMONA-4B a computer code with three-dimensional neutron kinetics for BWR and SBWR system transient - models and correlations

    Energy Technology Data Exchange (ETDEWEB)

    Rohatgi, U.S.; Cheng, H.S.; Khan, H.J.; Mallen, A.N.; Neymotin, L.Y.

    1998-03-01

    This document describes the major modifications and improvements made to the modeling of the RAMONA-3B/MOD0 code since 1981, when the code description and assessment report was completed. The new version of the code is RAMONA-4B. RAMONA-4B is a systems transient code for application to different versions of Boiling Water Reactors (BWR) such as the current BWR, the Advanced Boiling Water Reactor (ABWR), and the Simplified Boiling Water Reactor (SBWR). This code uses a three-dimensional neutron kinetics model coupled with a multichannel, non-equilibrium, drift-flux, two-phase flow formulation of the thermal hydraulics of the reactor vessel. The code is designed to analyze a wide spectrum of BWR core and system transients and instability issues. Chapter 1 is an overview of the code`s capabilities and limitations; Chapter 2 discusses the neutron kinetics modeling and the implementation of reactivity edits. Chapter 3 is an overview of the heat conduction calculations. Chapter 4 presents modifications to the thermal-hydraulics model of the vessel, recirculation loop, steam separators, boron transport, and SBWR specific components. Chapter 5 describes modeling of the plant control and safety systems. Chapter 6 presents and modeling of Balance of Plant (BOP). Chapter 7 describes the mechanistic containment model in the code. The content of this report is complementary to the RAMONA-3B code description and assessment document. 53 refs., 81 figs., 13 tabs.

  6. Real-time three-dimensional speckle tracking echocardiography: technical aspects and clinical applications

    Directory of Open Access Journals (Sweden)

    Sorrentino R

    2016-11-01

    Full Text Available Regina Sorrentino, Roberta Esposito, Enrica Pezzullo, Maurizio Galderisi Department of Advanced Biomedical Sciences, Interdepartmental Laboratory of Cardiac Imaging, Federico II University Hospital, Naples, Italy Abstract: Three-dimensional speckle tracking echocardiography (3D STE is a novel technique for the quantification of cardiac deformation based on tracking of ultrasonic speckles in gray scale full-volume 3D images. Developments in ultrasound technologies have made 3D speckle tracking widely available. Two-dimensional echocardiography has intrinsic limitations regarding estimation of left ventricular (LV volumes, ejection fraction, and LV mechanics, due to its inherent foreshortening errors and dependency on geometric models. The development of 3D echocardiography has improved reproducibility and accuracy. Data regarding the feasibility, accuracy, and clinical applications of 3D STE are rapidly assembling. From the tracking results, 3D STE derives several parameters, including longitudinal, circumferential and radial strain, as well as a combined assessment of longitudinal and circumferential strain, termed area strain. 3D STE can also quantify LV rotational movements such as rotation, twist, and torsion. 3D STE provides a better insight on global and regional myocardial deformation. Main applications include detection of subclinical myocardial involvement in heart failure, arterial hypertension, dyssynchrony, and ischemic heart disease. Emerging areas of application include a large spectrum of heart-involving systemic conditions, such as prediction of rejection in heart transplant patients, early detection of cardiotoxicity in patients receiving chemotherapy for cancer, and deeper physiological understanding of LV contraction mechanics in different types of athletes. Aim of this review is to discuss background, technical acquisition and processing aspects as well as recognized and developing clinical applications of this emerging

  7. Toxicity and cosmetic outcome of three-dimensional conformal radiotherapy for accelerated partial breast irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gatti, M.; Bresciani, S.; Ponzone, R.; Panaia, R.; Salatino, A.; Stasi, M.; Gabriele, P. [IRCC, Candiolo (Italy)

    2011-10-15

    Full text of publication follows: Purpose.- To analyse the incidence and severity of acute and late normal tissue toxicity and cosmetic outcome using three - dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Patients and Methods.- 70 patients with stage I disease were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation, in an approved protocol. The prescribed dose was 34 Gy in all patients delivered in 10 fractions over 5 consecutive days. On all CT scans gross tumor volume (GTV ) was defined around surgical clips. A 1.5 cm margin was added in order to account for clinical target volume (CTV) . A margin of 1 cm was added to CTI to define the planning target volume (PTV). The dose-volume constraints were followed in accordance with the specifications as dictated in the NSABP/RTOG protocol. After treatment, patients underwent a clinical and cosmetic evaluation every 3 months. Late toxicity was evaluated according to the RTOG grading schema. The cosmetic assessment was performed by the physicians using the controlateral untreated breast as the reference (Harvard scale). Results.- Median patient age was 66 years (range 51-80). Median follow-up was 15 months (range 6-46). Tumor size was < 10 mm in 33 patients (53%) and > 2 cm in 4(6%). The mean value of the ratio between the PTV and the whole ipsilateral breast volume was 38 % and the median percentage whole breast volume that received 95 % of prescribed dose was 34% (range 16%-55%). The rate of G1 and G2 acute skin toxicity was 28% and 2% respectively and the late toxicity was 17% (G1). G2 or greater toxicities were not observed. The most pronounced G1 late toxicity was subcutaneous fibrosis, developed in 3 patients. The cosmetic outcome was excellent in 83% and good in 17%. Conclusion.- Accelerated partial breast irradiation using three-dimensional conformal radiotherapy is technically feasible with very low acute and late toxicity. Long

  8. Spline-based image-to-volume registration for three-dimensional electron microscopy

    International Nuclear Information System (INIS)

    Jonic, S.; Sorzano, C.O.S.; Thevenaz, P.; El-Bez, C.; De Carlo, S.; Unser, M.

    2005-01-01

    This paper presents an algorithm based on a continuous framework for a posteriori angular and translational assignment in three-dimensional electron microscopy (3DEM) of single particles. Our algorithm can be used advantageously to refine the assignment of standard quantized-parameter methods by registering the images to a reference 3D particle model. We achieve the registration by employing a gradient-based iterative minimization of a least-squares measure of dissimilarity between an image and a projection of the volume in the Fourier transform (FT) domain. We compute the FT of the projection using the central-slice theorem (CST). To compute the gradient accurately, we take advantage of a cubic B-spline model of the data in the frequency domain. To improve the robustness of the algorithm, we weight the cost function in the FT domain and apply a 'mixed' strategy for the assignment based on the minimum value of the cost function at registration for several different initializations. We validate our algorithm in a fully controlled simulation environment. We show that the mixed strategy improves the assignment accuracy; on our data, the quality of the angular and translational assignment was better than 2 voxel (i.e., 6.54 A). We also test the performance of our algorithm on real EM data. We conclude that our algorithm outperforms a standard projection-matching refinement in terms of both consistency of 3D reconstructions and speed

  9. Three-dimensional reactor model for the Paks NPP full-scope simulator

    International Nuclear Information System (INIS)

    Gyori, C.; Hegyi, G.; Hozer, Z.; Kereszturi, A.; Maraczy, C.

    1993-01-01

    The reactor model includes thermohydraulic and neutron-physical components. The thermohydraulic model is based on the SMABRE code developed at the Technical Research Centre of Finland for the analysis of loss-of-coolant transients in PWRs. The fuel rod model will be replaced by a new software module providing a comprehensive description of the behavior of fuel rods during reactor transients and hypothetical accidents. The calculation is performed in four individual models: fuel rod temperature model, fuel rod internal pressure model, fuel rod deformation model and fuel rod failure model. In the neutron-physical model the core is calculated with nodes for all of the 349 fuel assemblies, and each assembly is calculated in ten layers. (Z.S.) 1 fig., 5 refs

  10. Three-dimensional volumetric assessment of response to treatment

    International Nuclear Information System (INIS)

    Willett, C.G.; Stracher, M.A.; Linggood, R.M.; Leong, J.C.; Skates, S.J.; Miketic, L.M.; Kushner, D.C.; Jacobson, J.O.

    1988-01-01

    From 1981 to 1986, 12 patients with Stage I and II diffuse large cell lymphoma of the mediastinum were treated with 4 or more cycles of multiagent chemotherapy and for nine patients this was followed by mediastinal irradiation. The response to treatment was assessed by three-dimensional volumetric analysis utilizing thoracic CT scans. The initial mean tumor volume of the five patients relapsing was 540 ml in contrast to an initial mean tumor volume of 360 ml for the seven patients remaining in remission. Of the eight patients in whom mediastinal lymphoma volumes could be assessed 1-2 months after chemotherapy prior to mediastinal irradiation, the three patients who have relapsed had volumes of 292, 92 and 50 ml (mean volume 145 ml) in contrast to five patients who have remained in remission with residual volume abnormalities of 4-87 ml (mean volume 32 ml). Four patients in prolonged remission with CT scans taken one year after treatment have been noted to have mediastinal tumor volumes of 0-28 ml with a mean value of 10 ml. This volumetric technique to assess the extent of mediastinal large cell lymphoma from thoracic CT scans appears to be a useful method to quantitate the amount of disease at presentation as well as objectively monitor response to treatment. 13 refs.; 2 figs.; 1 table

  11. Design of three-dimensional nonimaging concentrators with inhomogeneous media

    Science.gov (United States)

    Minano, J. C.

    1986-09-01

    A three-dimensional nonimaging concentrator is an optical system that transforms a given four-parametric manifold of rays reaching a surface (entry aperture) into another four-parametric manifold of rays reaching the receiver. A procedure of design of such concentrators is developed. In general, the concentrators use mirrors and inhomogeneous media (i.e., gradient-index media). The concentrator has the maximum concentration allowed by the theorem of conservation of phase-space volume. This is the first known concentrator with such properties. The Welford-Winston edge-ray principle in three-dimensional geometry is proven under several assumptions. The linear compound parabolic concentrator is derived as a particular case of the procedure of design.

  12. Reconstruction of pseudo three-dimensional dental image from dental panoramic radiograph and tooth surface shape

    International Nuclear Information System (INIS)

    Imura, Masataka; Kuroda, Yoshihiro; Oshiro, Osamu; Kuroda, Tomohiro; Kagiyama, Yoshiyuki; Yagi, Masakazu; Takada, Kenji; Azuma, Hiroko

    2010-01-01

    Three-dimensional volume data set is useful for diagnosis in dental treatments. However, to obtain three-dimensional images of a dental arch in general dental clinics is difficult. In this paper, we propose a method to reconstruct pseudo three-dimensional dental images from a dental panoramic radiograph and a tooth surface shape which can be obtained from three dimensional shape measurement of a dental impression. The proposed method finds an appropriate curved surface on which the dental panoramic radiograph is mapped by comparing a virtual panoramic image made from a tooth surface shape to a real panoramic radiograph. The developed pseudo three-dimensional dental images give clear impression of patient's dental condition. (author)

  13. Two-dimensional numerical simulation of flow around three-stranded rope

    Science.gov (United States)

    Wang, Xinxin; Wan, Rong; Huang, Liuyi; Zhao, Fenfang; Sun, Peng

    2016-08-01

    Three-stranded rope is widely used in fishing gear and mooring system. Results of numerical simulation are presented for flow around a three-stranded rope in uniform flow. The simulation was carried out to study the hydrodynamic characteristics of pressure and velocity fields of steady incompressible laminar and turbulent wakes behind a three-stranded rope. A three-cylinder configuration and single circular cylinder configuration are used to model the three-stranded rope in the two-dimensional simulation. The governing equations, Navier-Stokes equations, are solved by using two-dimensional finite volume method. The turbulence flow is simulated using Standard κ-ɛ model and Shear-Stress Transport κ-ω (SST) model. The drag of the three-cylinder model and single cylinder model is calculated for different Reynolds numbers by using control volume analysis method. The pressure coefficient is also calculated for the turbulent model and laminar model based on the control surface method. From the comparison of the drag coefficient and the pressure of the single cylinder and three-cylinder models, it is found that the drag coefficients of the three-cylinder model are generally 1.3-1.5 times those of the single circular cylinder for different Reynolds numbers. Comparing the numerical results with water tank test data, the results of the three-cylinder model are closer to the experiment results than the single cylinder model results.

  14. Monte Carlo simulation of the three-state vector Potts model on a three-dimensional random lattice

    International Nuclear Information System (INIS)

    Jianbo Zhang; Heping Ying

    1991-09-01

    We have performed a numerical simulation of the three-state vector Potts model on a three-dimensional random lattice. The averages of energy density, magnetization, specific heat and susceptibility of the system in the N 3 (N=8,10,12) lattices were calculated. The results show that a first order nature of the Z(3) symmetry breaking transition appears, as characterized by a thermal hysterisis in the energy density as well as an abrupt drop of magnetization being sharper and discontinuous with increasing of volume in the cross-over region. The results obtained on the random lattice were consistent with those obtained on the three-dimensional cubic lattice. (author). 12 refs, 4 figs

  15. Variation of clinical target volume definition in three-dimensional conformal radiation therapy for prostate cancer

    International Nuclear Information System (INIS)

    Valicenti, Richard K.; Sweet, John W.; Hauck, Walter W.; Hudes, Richard S.; Lee, Tony; Dicker, Adam P.; Waterman, Frank M.; Anne, Pramila R.; Corn, Benjamin W.; Galvin, James M.

    1999-01-01

    Purpose: Currently, three-dimensional conformal radiation therapy (3D-CRT) planning relies on the interpretation of computed tomography (CT) axial images for defining the clinical target volume (CTV). This study investigates the variation among multiple observers to define the CTV used in 3D-CRT for prostate cancer. Methods and Materials: Seven observers independently delineated the CTVs (prostate ± seminal vesicles [SV]) from the CT simulation data of 10 prostate cancer patients undergoing 3D-CRT. Six patients underwent CT simulation without the use of contrast material and serve as a control group. The other 4 had urethral and bladder opacification with contrast medium. To determine interobserver variation, we evaluated the derived volume, the maximum dimensions, and the isocenter for each examination of CTV. We assessed the reliability in the CTVs among the observers by correlating the variation for each class of measurements. This was estimated by intraclass correlation coefficient (ICC), with 1.00 defining absolute correlation. Results: For the prostate volumes, the ICC was 0.80 (95% confidence interval [CI]: 0.56-0.96). This changed to 0.92 (95% CI: 0.75-0.99) with the use of contrast material. Similarly, the maximal prostatic dimensions were reliable and improved. There was poor agreement in defining the SV. For this structure, the ICC never exceeded 0.28. The reliability of the isocenter was excellent, with the ICC exceeding 0.83 and 0.90 for the prostate ± SV, respectively. Conclusions: In 3D-CRT for prostate cancer, there was excellent agreement among multiple observers to define the prostate target volume but poor agreement to define the SV. The use of urethral and bladder contrast improved the reliability of localizing the prostate. For all CTVs, the isocenter was very reliable and should be used to compare the variation in 3D dosimetry among multiple observers

  16. Analysis of the Mannshan Unit 2 full load rejection transient

    International Nuclear Information System (INIS)

    Kang, J.C.; Pei, B.S.; Yu, G.P.; Yuann, R.Y.

    1987-01-01

    Mannshan Unit 2 is a Westinghouse three-loop pressurized water reactor with a rated core power of 2775 MW(thermal) and a rated core flow of 4702 kg/s. Before full power operation, a planned net load rejection was performed during the startup test by opening the main transformer highside breakers. The generator power rapidly reduced to station load. All 16 steam dump valves immediately popped open, and control bank-D rods automatically stepped in as the temperature difference T/sub avg/ - T/sub ref/ reached a programmed 2.8 0 C. Nuclear power decreased smoothly as control rods were inserted into the core. The pressurizer pressure and liquid levels also dropped. Neither safety injection nor reactor trip occurred during this transient. The test was done to verify that the whole system would function properly under a transient to keep the reactor from scramming and that the vessel integrity would also be protected. In this study, which is the preliminary stage of RELAP5/MOD2 transient simulation of the Mannshan PWR plants, system thermal-hydraulic response is tested first and isolated from the neutronic effects. The variation of core power versus time curve was extracted from the power test data to serve as a time varying boundary condition. The comparison of the analytical results of four major parameters (pressurizer pressure, average temperature of the core, steam dump flow rate, and feedwater flow rate) from RELAP5/MOD2 and the power test data is illustrated

  17. Dosimetric comparison of three-dimensional conformal and intensity modulated radiotherapy in brain glioma

    International Nuclear Information System (INIS)

    Lu Jie; Zhang Guifang; Bai Tong; Yin Yong; Fan Tingyong; Wu Chaoxia

    2009-01-01

    Objective: To investigate the dosimetry advantages of intensity modulated radiotherapy (IMRT)of brain glioma compared with that of three-dimensional conformal radiotherapy (SD CRT). Methods: Ten patients with brain glioma were enrolled in this study. Three-dimensional conf0rmal and intensity modulated radiotherapy plans were performed for each patient. The dose distributions of target volume and normal tissues, conformal index (CI) and heterogeneous index (HI) were analyzed using the dose-volume histogram (DVH). The prescription dose was 60 Gy in 30 fractions. Results: IMRT plans decrease the maximum dose and volume of brainstem, mean dose of affected side parotid and maximum dose of spinal-cord. The CI for PTV of IMRT was superior to that of SD CRT, the HI for PTV has no statistical significance of the two model plans. Conclusions: IMRT plans can obviously decrease the dose and volume of brainstem. IMRT is a potential method in the treatment of brain glioma, and dose escalation was possible in patients with brain glioma. (authors)

  18. Assessment of Normal Eyeball Protrusion Using Computed Tomographic Imaging and Three-Dimensional Reconstruction in Korean Adults.

    Science.gov (United States)

    Shin, Kang-Jae; Gil, Young-Chun; Lee, Shin-Hyo; Kim, Jeong-Nam; Yoo, Ja-Young; Kim, Soon-Heum; Choi, Hyun-Gon; Shin, Hyun Jin; Koh, Ki-Seok; Song, Wu-Chul

    2017-01-01

    The aim of the present study was to assess normal eyeball protrusion from the orbital rim using two- and three-dimensional images and demonstrate the better suitability of CT images for assessment of exophthalmos. The facial computed tomographic (CT) images of Korean adults were acquired in sagittal and transverse views. The CT images were used in reconstructing three-dimensional volume of faces using computer software. The protrusion distances from orbital rims and the diameters of eyeballs were measured in the two views of the CT image and three-dimensional volume of the face. Relative exophthalmometry was calculated by the difference in protrusion distance between the right and left sides. The eyeball protrusion was 4.9 and 12.5 mm in sagittal and transverse views, respectively. The protrusion distances were 2.9 mm in the three-dimensional volume of face. There were no significant differences between right and left sides in the degree of protrusion, and the difference was within 2 mm in more than 90% of the subjects. The results of the present study will provide reliable criteria for precise diagnosis and postoperative monitoring using CT imaging of diseases such as thyroid-associated ophthalmopathy and orbital tumors.

  19. Noninvasive, three-dimensional full-field body sensor for surface deformation monitoring of human body in vivo

    Science.gov (United States)

    Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin

    2017-09-01

    Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery.

  20. Simplest simulation model for three-dimensional xenon oscillations in large PWRs

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro

    2004-01-01

    Xenon oscillations in large PWRs are well understood and there have been no operational problems remained. However, in order to suppress the oscillations effectively, optimal control strategy is preferable. Generally speaking in such optimality search based on the modern control theory, a large volume of transient core analyses is required. For example, three dimensional core calculations are inevitable for the analyses of radial oscillations. From this point of view, a very simple 3-D model is proposed, which is based on a reactor model of only four points. As in the actual reactor operation, the magnitude of xenon oscillations should be limited from the view point of safety, the model further assumes that the neutron leakage can be also small or even constant. It can explicitly use reactor parameters such as reactivity coefficients and control rod worth directly. The model is so simplified as described above that it can predict oscillation behavior in a very short calculation time even on a PC. However the prediction result is good. The validity of the model in comparison with measured data and the applications are discussed. (author)

  1. Calculation of three-dimensional groundwater transport using second-order moments

    International Nuclear Information System (INIS)

    Pepper, D.W.; Stephenson, D.E.

    1987-01-01

    Groundwater transport of contaminants from the F-Area seepage basin at the Savannah River Plant (SRP) was calculated using a three-dimensional, second-order moment technique. The numerical method calculates the zero, first, and second moment distributions of concentration within a cell volume. By summing the moments over the entire solution domain, and using a Lagrangian advection scheme, concentrations are transported without numerical dispersion errors. Velocities obtained from field tests are extrapolated and interpolated to all nodal points; a variational analysis is performed over the three-dimensional velocity field to ensure mass consistency. Transport predictions are calculated out to 12,000 days. 28 refs., 9 figs

  2. Unsteady single-phase natural circulation flow mixing prediction using CATHARE three-dimensional capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Salah, Anis Bousbia; Vlassenbroeck, Jacques [Bel V - Subsidiary of the Belgian Federal Agency for Nuclear Contro, Brussels (Belize)

    2017-04-15

    Coolant mixing under natural circulation flow regime constitutes a key parameter that may play a role in the course of an accidental transient in a nuclear pressurized water reactor. This issue has motivated some experimental investigations carried out within the OECD/NEA PKL projects. The aim was to assess the coolant mixing phenomenon in the reactor pressure vessel downcomer and the core lower plenum under several asymmetric steady and unsteady flow conditions, and to provide experimental data for code validations. Former studies addressed the mixing phenomenon using, on the one hand, one-dimensional computational approaches with cross flows that are not fully validated under transient conditions and, on the other hand, expensive computational fluid dynamic tools that are not always justified for large-scale macroscopic phenomena. In the current framework, an unsteady coolant mixing experiment carried out in the Rossendorf coolant mixing test facility is simulated using the three-dimensional porous media capabilities of the thermal–hydraulic system CATHARE code. The current study allows highlighting the current capabilities of these codes and their suitability for reproducing the main phenomena occurring during asymmetric transient natural circulation mixing conditions.

  3. Clinical significance of three-dimensional sonohysterography

    International Nuclear Information System (INIS)

    Lee, Eun Hye; Lee, Mi Hwa; Lee, Chan; Kim, Jong Wook; Shin, Myung Choel

    1999-01-01

    To evaluate the usefulness of three dimensional sonohysterography (3D SHG) in the evaluation of uterine endometrial and submucosal lesions in comparison with conventional two-dimensional sonohysterography (2D SHG). Our series consisted of 26 patients (mean aged 41 years) who complained of uterine bleeding, menorrhagia, or dysmenorrhea. 2D SHG was performed, and then 3D SHG was done after the volume mode was switched on. Simultaneous display of three perpendicular two-dimensional planes and surface rendering of findings on particular section were obtained. We analyzed whether the endometrium was thickened or not, and the location, size, shape, echogenicity, posterior shadowing, and echogenic rim of the focal lesion. The results were compared with the pathologic findings or MRI. There were submucosal myomas (n=12), intramural myomas (n=2), endometrial polyps (n=7), placental polyp (n=1), and normal endometrial cavities (n=4) on SHG. Nineteen cases were confirmed by pathologic findings or MRI. The results were correlated in 89% (17/19) of the cases. We misdiagnosed 2 cases: focal endometrial hyperplasia and choriocarcinoma were misdiagnosed as endometrial polyp and placental polyp, respectively. Imaging diagnoses were same in the techniques. Comparing with 2D SHG, 3D SHG provided a subjective display of pathologic findings and an additional information about spatial relationship between focal lesion and surroundings.

  4. Clinical significance of three-dimensional sonohysterography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Hye; Lee, Mi Hwa; Lee, Chan; Kim, Jong Wook; Shin, Myung Choel [Pochon Cha University College of Medicine, Pochon (Korea, Republic of)

    1999-12-15

    To evaluate the usefulness of three dimensional sonohysterography (3D SHG) in the evaluation of uterine endometrial and submucosal lesions in comparison with conventional two-dimensional sonohysterography (2D SHG). Our series consisted of 26 patients (mean aged 41 years) who complained of uterine bleeding, menorrhagia, or dysmenorrhea. 2D SHG was performed, and then 3D SHG was done after the volume mode was switched on. Simultaneous display of three perpendicular two-dimensional planes and surface rendering of findings on particular section were obtained. We analyzed whether the endometrium was thickened or not, and the location, size, shape, echogenicity, posterior shadowing, and echogenic rim of the focal lesion. The results were compared with the pathologic findings or MRI. There were submucosal myomas (n=12), intramural myomas (n=2), endometrial polyps (n=7), placental polyp (n=1), and normal endometrial cavities (n=4) on SHG. Nineteen cases were confirmed by pathologic findings or MRI. The results were correlated in 89% (17/19) of the cases. We misdiagnosed 2 cases: focal endometrial hyperplasia and choriocarcinoma were misdiagnosed as endometrial polyp and placental polyp, respectively. Imaging diagnoses were same in the techniques. Comparing with 2D SHG, 3D SHG provided a subjective display of pathologic findings and an additional information about spatial relationship between focal lesion and surroundings.

  5. Three-dimensional wound measurements for monitoring wound healing

    DEFF Research Database (Denmark)

    Bisgaard Jørgensen, Line; Møller Jeppesen, Sune; Halekoh, Ulrich

    Telemedicine is increasingly used for monitoring wound healing. Three-dimensional (3D) measurement methods enable clinicians to assess wound healing with respect to all dimensions. However, the currently available methods are inaccurate, costly or complicated to use. To address these issues, a 3D......-WAM camera was developed. This camera is able to measure wound size (2D area, 3D area, perimeter and volume) and to assess wound characteristics....

  6. A finite area scheme for shallow granular flows on three-dimensional surfaces

    Science.gov (United States)

    Rauter, Matthias

    2017-04-01

    Shallow granular flow models have become a popular tool for the estimation of natural hazards, such as landslides, debris flows and avalanches. The shallowness of the flow allows to reduce the three-dimensional governing equations to a quasi two-dimensional system. Three-dimensional flow fields are replaced by their depth-integrated two-dimensional counterparts, which yields a robust and fast method [1]. A solution for a simple shallow granular flow model, based on the so-called finite area method [3] is presented. The finite area method is an adaption of the finite volume method [4] to two-dimensional curved surfaces in three-dimensional space. This method handles the three dimensional basal topography in a simple way, making the model suitable for arbitrary (but mildly curved) topography, such as natural terrain. Furthermore, the implementation into the open source software OpenFOAM [4] is shown. OpenFOAM is a popular computational fluid dynamics application, designed so that the top-level code mimics the mathematical governing equations. This makes the code easy to read and extendable to more sophisticated models. Finally, some hints on how to get started with the code and how to extend the basic model will be given. I gratefully acknowledge the financial support by the OEAW project "beyond dense flow avalanches". Savage, S. B. & Hutter, K. 1989 The motion of a finite mass of granular material down a rough incline. Journal of Fluid Mechanics 199, 177-215. Ferziger, J. & Peric, M. 2002 Computational methods for fluid dynamics, 3rd edn. Springer. Tukovic, Z. & Jasak, H. 2012 A moving mesh finite volume interface tracking method for surface tension dominated interfacial fluid flow. Computers & fluids 55, 70-84. Weller, H. G., Tabor, G., Jasak, H. & Fureby, C. 1998 A tensorial approach to computational continuum mechanics using object-oriented techniques. Computers in physics 12(6), 620-631.

  7. Three-dimensional photography for the evaluation of facial profiles in obstructive sleep apnoea.

    Science.gov (United States)

    Lin, Shih-Wei; Sutherland, Kate; Liao, Yu-Fang; Cistulli, Peter A; Chuang, Li-Pang; Chou, Yu-Ting; Chang, Chih-Hao; Lee, Chung-Shu; Li, Li-Fu; Chen, Ning-Hung

    2018-06-01

    Craniofacial structure is an important determinant of obstructive sleep apnoea (OSA) syndrome risk. Three-dimensional stereo-photogrammetry (3dMD) is a novel technique which allows quantification of the craniofacial profile. This study compares the facial images of OSA patients captured by 3dMD to three-dimensional computed tomography (3-D CT) and two-dimensional (2-D) digital photogrammetry. Measurements were correlated with indices of OSA severity. Thirty-eight patients diagnosed with OSA were included, and digital photogrammetry, 3dMD and 3-D CT were performed. Distances, areas, angles and volumes from the images captured by three methods were analysed. Almost all measurements captured by 3dMD showed strong agreement with 3-D CT measurements. Results from 2-D digital photogrammetry showed poor agreement with 3-D CT. Mandibular width, neck perimeter size and maxillary volume measurements correlated well with the severity of OSA using all three imaging methods. Mandibular length, facial width, binocular width, neck width, cranial base triangle area, cranial base area 1 and middle cranial fossa volume correlated well with OSA severity using 3dMD and 3-D CT, but not with 2-D digital photogrammetry. 3dMD provided accurate craniofacial measurements of OSA patients, which were highly concordant with those obtained by CT, while avoiding the radiation associated with CT. © 2018 Asian Pacific Society of Respirology.

  8. Three-dimensional multi-physics model of the European sodium fast reactor design applied to DBA analysis - 15293

    International Nuclear Information System (INIS)

    Lazaro, A.; Ordonez, J.; Martorell, S.; Przemyslaw, S.; Ammirabile, L.; Tsige-Tamirat, H.

    2015-01-01

    The sodium cooled fast reactor (SFR) is one of the reactor types selected by the Generation IV International Forum. SFR stand out due to its remarkable past operational experience in related projects and its potential to achieve the ambitious goals laid for the new generation of nuclear reactors. Regardless its operational experience, there is a need to apply computational tools able to simulate the system behaviour under conditions that may overtake the reactor safety limits from the early stages of the design process, including the three-dimensional phenomena that may arise in these transients. This paper presents the different steps followed towards the development of a multi-physics platform with capabilities to simulate complex phenomena using a coupled neutronic-thermal-hydraulic scheme. The development started with a one-dimensional thermal-hydraulic model of the European Sodium Fast Reactor (ESFR) design with point kinetic neutronic feedback benchmarked with its peers in the framework of the FP7-CP-ESFR project using the state-of-the-art thermal-hydraulic system code TRACE. The model was successively extended into a three-dimensional model coupled with the spatial kinetic neutronic code PARCS able to simulate three-dimensional multi-physic phenomena along with the comparison of the results for symmetric cases. The last part of the paper shows the application of the developed tool to the analysis of transients involving asymmetrical effects, such as the coast-down of a primary and secondary pump or the withdrawal of a peripheral control rod bank, demonstrating the unique capability of the code to simulate such transients and the capability of the design to withstand them under design basis

  9. Phase Diagrams of Three-Dimensional Anderson and Quantum Percolation Models Using Deep Three-Dimensional Convolutional Neural Network

    Science.gov (United States)

    Mano, Tomohiro; Ohtsuki, Tomi

    2017-11-01

    The three-dimensional Anderson model is a well-studied model of disordered electron systems that shows the delocalization-localization transition. As in our previous papers on two- and three-dimensional (2D, 3D) quantum phase transitions [J. Phys. Soc. Jpn. 85, 123706 (2016), 86, 044708 (2017)], we used an image recognition algorithm based on a multilayered convolutional neural network. However, in contrast to previous papers in which 2D image recognition was used, we applied 3D image recognition to analyze entire 3D wave functions. We show that a full phase diagram of the disorder-energy plane is obtained once the 3D convolutional neural network has been trained at the band center. We further demonstrate that the full phase diagram for 3D quantum bond and site percolations can be drawn by training the 3D Anderson model at the band center.

  10. Analysis and validation of carbohydrate three-dimensional structures

    International Nuclear Information System (INIS)

    Lütteke, Thomas

    2009-01-01

    The article summarizes the information that is gained from and the errors that are found in carbohydrate structures in the Protein Data Bank. Validation tools that can locate these errors are described. Knowledge of the three-dimensional structures of the carbohydrate molecules is indispensable for a full understanding of the molecular processes in which carbohydrates are involved, such as protein glycosylation or protein–carbohydrate interactions. The Protein Data Bank (PDB) is a valuable resource for three-dimensional structural information on glycoproteins and protein–carbohydrate complexes. Unfortunately, many carbohydrate moieties in the PDB contain inconsistencies or errors. This article gives an overview of the information that can be obtained from individual PDB entries and from statistical analyses of sets of three-dimensional structures, of typical problems that arise during the analysis of carbohydrate three-dimensional structures and of the validation tools that are currently available to scientists to evaluate the quality of these structures

  11. Three Dimensional Polarimetric Neutron Tomography of Magnetic Fields

    DEFF Research Database (Denmark)

    Sales, Morten; Strobl, Markus; Shinohara, Takenao

    2018-01-01

    Through the use of Time-of-Flight Three Dimensional Polarimetric Neutron Tomography (ToF 3DPNT) we have for the first time successfully demonstrated a technique capable of measuring and reconstructing three dimensional magnetic field strengths and directions unobtrusively and non-destructively wi......Through the use of Time-of-Flight Three Dimensional Polarimetric Neutron Tomography (ToF 3DPNT) we have for the first time successfully demonstrated a technique capable of measuring and reconstructing three dimensional magnetic field strengths and directions unobtrusively and non...... and reconstructed, thereby providing the proof-of-principle of a technique able to reveal hitherto unobtainable information on the magnetic fields in the bulk of materials and devices, due to a high degree of penetration into many materials, including metals, and the sensitivity of neutron polarisation to magnetic...... fields. The technique puts the potential of the ToF time structure of pulsed neutron sources to full use in order to optimise the recorded information quality and reduce measurement time....

  12. Three-dimensional, three-component wall-PIV

    Science.gov (United States)

    Berthe, André; Kondermann, Daniel; Christensen, Carolyn; Goubergrits, Leonid; Garbe, Christoph; Affeld, Klaus; Kertzscher, Ulrich

    2010-06-01

    This paper describes a new time-resolved three-dimensional, three-component (3D-3C) measurement technique called wall-PIV. It was developed to assess near wall flow fields and shear rates near non-planar surfaces. The method is based on light absorption according to Beer-Lambert’s law. The fluid containing a molecular dye and seeded with buoyant particles is illuminated by a monochromatic, diffuse light. Due to the dye, the depth of view is limited to the near wall layer. The three-dimensional particle positions can be reconstructed by the intensities of the particle’s projection on an image sensor. The flow estimation is performed by a new algorithm, based on learned particle trajectories. Possible sources of measurement errors related to the wall-PIV technique are analyzed. The accuracy analysis was based on single particle experiments and a three-dimensional artificial data set simulating a rotating sphere.

  13. Analysis of three-dimensional transient seepage into ditch drains ...

    Indian Academy of Sciences (India)

    Ratan Sarmah

    waterlogged soils in many regions of the world, including. India [2, 6–9]—to name a ... predicting two-dimensional seepage into a network of ...... when d1 ¼ 0, the lower limits of integration of the integral ...... and agricultural development. Irrig.

  14. Diffraction limited focusing with controllable arbitrary three-dimensional polarization

    International Nuclear Information System (INIS)

    Chen, Weibin; Zhan, Qiwen

    2010-01-01

    We propose a new approach that enables full control over the three-dimensional state of polarization and the field distribution near the focus of a high numerical aperture objective lens. By combining the electric dipole radiation and a vectorial diffraction method, the input field at the pupil plane for generating arbitrary three-dimensionally oriented linear polarization at the focal point with a diffraction limited spot size is found analytically by solving the inverse problem. Arbitrary three-dimensional elliptical polarization can be obtained by introducing a second electric dipole oriented in the orthogonal plane with appropriate amplitude and phase differences

  15. Quantitative analysis of normal fetal medulla oblongata volume and flow by three-dimensional power Doppler ultrasound.

    Science.gov (United States)

    Shyu, Ing-Luen; Wang, Peng-Hui; Chen, Chih-Yao; Chen, Yi-Jen; Chang, Chia-Ming; Horng, Huann-Cheng; Yang, Ming-Jie; Yen, Ming-Shyen

    2016-06-01

    Assessment of the fetal medulla oblongata volume (MOV) and blood flow might be important in the evaluation of fetal brain growth. We used three-dimensional power Doppler ultrasound (3DPDUS) to assess the fetal MOV and blood flow index in normal gestation. The relationships between these parameters were further analyzed. We assessed the total volume and blood flow index of the fetal MO in normal pregnancies using a 3DPDUS (Voluson 730 Expert). The true sagittal plane over the fetal occipital area was measured by a 3D transabdominal probe to scan the fetal MO under the power Doppler mode. Then, we quantitatively assessed the total volume of the fetal MOV, mean gray area (MG), vascularization index (VI), and flow index (FI). A total of 106 fetuses, ranging from 19 weeks to 39 weeks of gestation, were involved in our study. The volume of the fetal MO was highly positively correlated with gestational age [correlation coefficient (r) = 0.686, p < 0.0001]. The MG was negatively correlated with gestational age [r = -0.544, p < 0.0001). VI and FI showed no significant correlation with gestational age (p = 0.123 and p = 0.219, respectively). 3DPDUS can be used to assess the fetal MOV and blood flow development quantitatively. Our study indicated that fetal MOV and blood flow correlated significantly with the advancement of gestational age. This information may serve as reference data for further studies of the fetal brain and blood flow under abnormal conditions. Copyright © 2016. Published by Elsevier B.V.

  16. Analysis of one-dimensional nonequilibrium two-phase flow using control volume method

    International Nuclear Information System (INIS)

    Minato, Akihiko; Naitoh, Masanori

    1987-01-01

    A one-dimensional numerical analysis model was developed for prediction of rapid flow transient behavior involving boiling. This model was based on six conservation equations of time averaged parameters of gas and liquid behavior. These equations were solved by using a control volume method with an explicit time integration. This model did not use staggered mesh scheme, which had been commonly used in two-phase flow analysis. Because void fraction and velocity of each phase were defined at the same location in the present model, effects of void fraction on phase velocity calculation were treated directly without interpolation. Though non-staggered mesh scheme was liable to cause numerical instability with zigzag pressure field, stability was achieved by employing the Godunov method. In order to verify the present analytical model, Edwards' pipe blow down and Zaloudek's initially subcooled critical two-phase flow experiments were analyzed. Stable solutions were obtained for rarefaction wave propagation with boiling and transient two-phase flow behavior in a broken pipe by using this model. (author)

  17. One-dimensional transient radiative transfer by lattice Boltzmann method.

    Science.gov (United States)

    Zhang, Yong; Yi, Hongliang; Tan, Heping

    2013-10-21

    The lattice Boltzmann method (LBM) is extended to solve transient radiative transfer in one-dimensional slab containing scattering media subjected to a collimated short laser irradiation. By using a fully implicit backward differencing scheme to discretize the transient term in the radiative transfer equation, a new type of lattice structure is devised. The accuracy and computational efficiency of this algorithm are examined firstly. Afterwards, effects of the medium properties such as the extinction coefficient, the scattering albedo and the anisotropy factor, and the shapes of laser pulse on time-resolved signals of transmittance and reflectance are investigated. Results of the present method are found to compare very well with the data from the literature. For an oblique incidence, the LBM results in this paper are compared with those by Monte Carlo method generated by ourselves. In addition, transient radiative transfer in a two-Layer inhomogeneous media subjected to a short square pulse irradiation is investigated. At last, the LBM is further extended to study the transient radiative transfer in homogeneous medium with a refractive index discontinuity irradiated by the short pulse laser. Several trends on the time-resolved signals different from those for refractive index of 1 (i.e. refractive-index-matched boundary) are observed and analysed.

  18. Comparison of one-dimensional and point kinetics for various light water reactor transients

    International Nuclear Information System (INIS)

    Naser, J.A.; Lin, C.; Gose, G.C.; McClure, J.A.; Matsui, Y.

    1985-01-01

    The object of this paper is to compare the results from the three kinetics options: 1) point kinetics; 2) point kinetics by not changing the shape function; and 3) one-dimensional kinetics for various transients on both BWRs and PWRs. A systematic evaluation of the one-dimensional kinetics calculation and its alternatives is performed to determine the status of these models and to identify additional development work. In addition, for PWRs, the NODEP-2 - NODETRAN and SIMULATE - SIMTRAN paths for calculating kinetics parameters are compared. This type of comparison has not been performed before and is needed to properly evaluate the RASP methodology of which these codes are a part. It should be noted that RASP is in its early pre-release stage and this is the first serious attempt to examine the consistency between these two similar but different methods of generating physics parameters for the RETRAN computer code

  19. Summary of three-dimensional animation creation based on ethnic culture element

    Directory of Open Access Journals (Sweden)

    Shao Zhaopo

    2016-01-01

    Full Text Available three-dimensional animation is a product combined by technology and art. It is an artistic ex-pression form combining painting, film & television, digital technology, music, and literature. As an audio and visual art, three-dimensional animation has its own unique culture-loading function, technical aesthetic charac-teristics, and requirements for national art expression. This paper aims to find the method to combine digital technology and national art in combination of three-dimensional animation short film creation, and hopes to clear the road for the cultivation of domestic three-dimensional animation quality project.

  20. A comparison of two three-dimensional shell-element transient electromagnetics codes

    International Nuclear Information System (INIS)

    Yugo, J.J.; Williamson, D.E.

    1992-01-01

    Electromagnetic forces due to eddy currents strongly influence the design of components for the next generation of fusion devices. An effort has been made to benchmark two computer programs used to generate transient electromagnetic loads: SPARK and EddyCuFF. Two simple transient field problems were analyzed, both of which had been previously analyzed by the SPARK code with results recorded in the literature. A third problem that uses an ITER inboard blanket benchmark model was analyzed as well. This problem was driven with a self-consistent, distributed multifilament plasma model generated by an axisymmetric physics code. The benchmark problems showed good agreement between the two shell-element codes. Variations in calculated eddy currents of 1--3% have been found for similar, finely meshed models. A difference of 8% was found in induced current and 20% in force for a coarse mesh and complex, multifilament field driver. Because comparisons were made to results obtained from literature, model preparation and code execution times were not evaluated

  1. Three-dimensional cloud characterization from paired whole-sky imaging cameras

    International Nuclear Information System (INIS)

    Allmen, M.; Kegelmeyer, W.P. Jr.

    1994-01-01

    Three-dimensional (3-D) cloud characterization permits the derivation of important cloud geometry properties such as fractional cloudiness, mean cloud and clear length, aspect ratio, and the morphology of cloud cover. These properties are needed as input to the hierarchical diagnosis (HD) and instantaneous radiative transfer (IRF) models, to validate sub-models for cloud occurrence and formation, and to Central Site radiative flux calculations. A full 3-D characterization will eventually require the integration of disparate Cloud and Radiation Testbed (CART) data sources: whole-sky imagers (WSIs), radar, satellites, ceilometers, volume-imaging lidar, and other sensors. In this paper, we demonstrate how an initial 3-D cloud property, cloud base height, can be determined from fusing paired times series of images from two whole-sky imagers

  2. Three-dimensional orientation-unlimited polarization encryption by a single optically configured vectorial beam.

    Science.gov (United States)

    Li, Xiangping; Lan, Tzu-Hsiang; Tien, Chung-Hao; Gu, Min

    2012-01-01

    The interplay between light polarization and matter is the basis of many fundamental physical processes and applications. However, the electromagnetic wave nature of light in free space sets a fundamental limit on the three-dimensional polarization orientation of a light beam. Although a high numerical aperture objective can be used to bend the wavefront of a radially polarized beam to generate the longitudinal polarization state in the focal volume, the arbitrary three-dimensional polarization orientation of a beam has not been achieved yet. Here we present a novel technique for generating arbitrary three-dimensional polarization orientation by a single optically configured vectorial beam. As a consequence, by applying this technique to gold nanorods, orientation-unlimited polarization encryption with ultra-security is demonstrated. These results represent a new landmark of the orientation-unlimited three-dimensional polarization control of the light-matter interaction.

  3. Coherent optical nonlinearities and phase relaxation of quasi-three-dimensional and quasi-two-dimensional excitons in ZnSxSe1 - x/ZnSe structures

    DEFF Research Database (Denmark)

    Wagner, Hans Peter; Schätz, A.; Maier, R.

    1997-01-01

    We investigate the dephasing of heavy-hole excitons in different free-standing ZnSxSe1-x/ZnSe layer structures by spectrally resolved transient four-wave mixing. ZnSe layers of 80, 8, and 4 nm thickness with ternary barriers are studied, representing the crossover from quasi-three-dimensional to ...

  4. Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function—Current Clinical Applications and Literature Review Update

    Directory of Open Access Journals (Sweden)

    Morgan Q. Beckett

    2017-03-01

    Full Text Available Our review of real-time three-dimensional echocardiography (RT3DE discusses the diagnostic utility of RT3DE and provides a comparison with two-dimensional echocardiography (2DE in clinical cardiology. A Pubmed literature search on RT3DE was performed using the following key words: transthoracic, two-dimensional, three-dimensional, real-time, and left ventricular (LV function. Articles included perspective clinical studies and meta-analyses in the English language, and focused on the role of RT3DE in human subjects. Application of RT3DE includes analysis of the pericardium, right ventricular (RV and LV cavities, wall motion, valvular disease, great vessels, congenital anomalies, and traumatic injury, such as myocardial contusion. RT3DE, through a transthoracic echocardiography (TTE, allows for increasingly accurate volume and valve motion assessment, estimated LV ejection fraction, and volume measurements. Chamber motion and LV mass approximation have been more accurately evaluated by RT3DE by improved inclusion of the third dimension and quantification of volumetric movement. Moreover, RT3DE was shown to have no statistical significance when comparing the ejection fractions of RT3DE to cardiac magnetic resonance (CMR. Analysis of RT3DE data sets of the LV endocardial exterior allows for the volume to be directly quantified for specific phases of the cardiac cycle, ranging from end systole to end diastole, eliminating error from wall motion abnormalities and asymmetrical left ventricles. RT3DE through TTE measures cardiac function with superior diagnostic accuracy in predicting LV mass, systolic function, along with LV and RV volume when compared with 2DE with comparable results to CMR.

  5. Usefulness Of Three-Dimensional Printing Models for Patients with Stoma Construction

    Directory of Open Access Journals (Sweden)

    Tetsuro Tominaga

    2016-04-01

    Full Text Available The use of patient-specific organ models in three-dimensional printing systems could be helpful for the education of patients and medical students. The aim of this study was to clarify whether the use of patient-specific stoma models is helpful for patient education. From January 2014 to September 2014, 5 patients who underwent colorectal surgery and for whom a temporary or permanent stoma had been created were involved in this study. Three-dimensional stoma models and three-dimensional face plates were created. The patients’ ages ranged from 59 to 81 years. Four patients underwent stoma construction because of rectal cancer, and 1 underwent stoma construction because of colon stenosis secondary to recurrent cancer. All patients were educated about their stoma and potential stoma-associated problems using three-dimensional stoma models, and all practiced cutting face plates using three-dimensional face plates. The models were also used during medical staff conferences to discuss current issues. All patients understood their problems and finally became self-reliant. The recent availability of three-dimensional printers has enabled the creation of many organ models, and full-scale stoma and face plate models are now available for patient education on cutting an appropriately individualized face plate. Thus, three-dimensional printers could enable fewer skin problems than are currently associated with daily stomal care.

  6. Three-dimensional harmonic control of a nuclear reactor

    International Nuclear Information System (INIS)

    Potapenko, P.T.

    1989-01-01

    Algorithms for neutron flux control based on harmonic three-dimensional core are considered. The essence of the considered approach includes determination of harmonics amplitudes by signals self-powered detectors placed in reactor channels and reconstruction of neutron field distribution over the reactor core volume using the data obtained. Neutron field harmonic control is shown to be reduced to independent measurement and calculation of height harmonics in channels using techniques developed for channel power control

  7. Real-time interpolation for true 3-dimensional ultrasound image volumes.

    Science.gov (United States)

    Ji, Songbai; Roberts, David W; Hartov, Alex; Paulsen, Keith D

    2011-02-01

    We compared trilinear interpolation to voxel nearest neighbor and distance-weighted algorithms for fast and accurate processing of true 3-dimensional ultrasound (3DUS) image volumes. In this study, the computational efficiency and interpolation accuracy of the 3 methods were compared on the basis of a simulated 3DUS image volume, 34 clinical 3DUS image volumes from 5 patients, and 2 experimental phantom image volumes. We show that trilinear interpolation improves interpolation accuracy over both the voxel nearest neighbor and distance-weighted algorithms yet achieves real-time computational performance that is comparable to the voxel nearest neighbor algrorithm (1-2 orders of magnitude faster than the distance-weighted algorithm) as well as the fastest pixel-based algorithms for processing tracked 2-dimensional ultrasound images (0.035 seconds per 2-dimesional cross-sectional image [76,800 pixels interpolated, or 0.46 ms/1000 pixels] and 1.05 seconds per full volume with a 1-mm(3) voxel size [4.6 million voxels interpolated, or 0.23 ms/1000 voxels]). On the basis of these results, trilinear interpolation is recommended as a fast and accurate interpolation method for rectilinear sampling of 3DUS image acquisitions, which is required to facilitate subsequent processing and display during operating room procedures such as image-guided neurosurgery.

  8. Numerical method for three dimensional steady-state two-phase flow calculations

    International Nuclear Information System (INIS)

    Raymond, P.; Toumi, I.

    1992-01-01

    This paper presents the numerical scheme which was developed for the FLICA-4 computer code to calculate three dimensional steady state two phase flows. This computer code is devoted to steady state and transient thermal hydraulics analysis of nuclear reactor cores 1,3 . The first section briefly describes the FLICA-4 flow modelling. Then in order to introduce the numerical method for steady state computations, some details are given about the implicit numerical scheme based upon an approximate Riemann solver which was developed for calculation of flow transients. The third section deals with the numerical method for steady state computations, which is derived from this previous general scheme and its optimization. We give some numerical results for steady state calculations and comparisons on required CPU time and memory for various meshing and linear system solvers

  9. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  10. Three-dimensional effects in fracture mechanics

    International Nuclear Information System (INIS)

    Benitez, F.G.

    1991-01-01

    An overall view of the pioneering theories and works, which enlighten the three-dimensional nature of fracture mechanics during the last years is given. the main aim is not an exhaustive reviewing but the displaying of the last developments on this scientific field in a natural way. This work attempts to envisage the limits of disregarding the three-dimensional behaviour in theories, analyses and experiments. Moreover, it tries to draw attention on the scant fervour, although increasing, this three-dimensional nature of fracture has among the scientific community. Finally, a constructive discussion is presented on the use of two-dimensional solutions in the analysis of geometries which bear a three-dimensional configuration. the static two-dimensional solutions and its applications fields are reviewed. also, the static three-dimensional solutions, wherein a comparative analysis with elastoplastic and elastostatic solutions are presented. to end up, the dynamic three-dimensional solutions are compared to the asymptotic two-dimensional ones under the practical applications point of view. (author)

  11. Editorial Commentary: Single-Image Slice Magnetic Resonance Imaging Assessments Do Not Predict 3-Dimensional Muscle Volume.

    Science.gov (United States)

    Brand, Jefferson C

    2016-01-01

    No single-image magnetic resonance imaging (MRI) assessment-Goutallier classification, Fuchs classification, or cross-sectional area-is predictive of whole-muscle volume or fatty atrophy of the supraspinatus or infraspinatus. Rather, 3-dimensional MRI measurement of whole-muscle volume and fat-free muscle volume is required and is associated with shoulder strength, which is clinically relevant. Three-dimensional MRI may represent a new gold standard for assessment of the rotator cuff musculature using imaging and may help to predict the feasibility of repair of a rotator cuff tear as well as the postoperative outcome. Unfortunately, 3-dimensional MRI assessment of muscle volume is labor intensive and is not widely available for clinical use. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. THREE DIMENSIONAL GRAPHICAL REPRESENTATION OF QUALITY

    Directory of Open Access Journals (Sweden)

    Vineet V. Kumar

    2014-03-01

    Full Text Available Quality is an important aspect for every firm in modern era of competition. Every product has tough competition in terms of market reach. The factor, which actually makes any product long run in market, is quality and hence quality is the stepping-stone for success of any firm. For everyone meaning of quality is different. We have seen several economists who have defined quality by considering different factors, but what all of them have common in them is Customer satisfaction. Customer satisfaction is the ultimate result of quality. In three-dimensional graphical representation of quality, optimum quality is obtained by using three-dimensional graph by considering some important factors governing quality of any product, limiting factor, and customer satisfaction.

  13. Electron tomography, three-dimensional Fourier analysis and colour prediction of a three-dimensional amorphous biophotonic nanostructure

    Science.gov (United States)

    Shawkey, Matthew D.; Saranathan, Vinodkumar; Pálsdóttir, Hildur; Crum, John; Ellisman, Mark H.; Auer, Manfred; Prum, Richard O.

    2009-01-01

    Organismal colour can be created by selective absorption of light by pigments or light scattering by photonic nanostructures. Photonic nanostructures may vary in refractive index over one, two or three dimensions and may be periodic over large spatial scales or amorphous with short-range order. Theoretical optical analysis of three-dimensional amorphous nanostructures has been challenging because these structures are difficult to describe accurately from conventional two-dimensional electron microscopy alone. Intermediate voltage electron microscopy (IVEM) with tomographic reconstruction adds three-dimensional data by using a high-power electron beam to penetrate and image sections of material sufficiently thick to contain a significant portion of the structure. Here, we use IVEM tomography to characterize a non-iridescent, three-dimensional biophotonic nanostructure: the spongy medullary layer from eastern bluebird Sialia sialis feather barbs. Tomography and three-dimensional Fourier analysis reveal that it is an amorphous, interconnected bicontinuous matrix that is appropriately ordered at local spatial scales in all three dimensions to coherently scatter light. The predicted reflectance spectra from the three-dimensional Fourier analysis are more precise than those predicted by previous two-dimensional Fourier analysis of transmission electron microscopy sections. These results highlight the usefulness, and obstacles, of tomography in the description and analysis of three-dimensional photonic structures. PMID:19158016

  14. Three-dimensional MRI of the glenoid labrum

    International Nuclear Information System (INIS)

    Loehr, S.P.; Pope, T.L. Jr.; Martin, D.F.; Link, K.M.; Monu, J.U.V.; Hunter, M.; Reboussin, D.

    1995-01-01

    The objective of this study was to assess the accuracy of three-dimensional (3D) magnetic resonance imaging (MRI) reformation in the evaluation of tears of the glenoid labrum complex (GLC). Fifty-five shoulders were evaluated by MRI using standard spin-echo sequences. Gradient-refocused-echo axial projections were used to assess the GLC on the two-dimensional (2D) studies. Three-dimensional Fourier transform multiplanar gradient-recalled imaging with a resolution of 0.7 mm was also performed in all patients. Independent analyses of the anterior and posterior labra were performed in a blinded manner for both the 2D and 3D studies by three experienced musculoskeletal radiologists. Observations of the imaging studies were compared with the videoarthroscopic findings. The appearance of the GLC was rated on a scale of 0 to 4 (0-2=normal, 3, 4=abnormal or torn). The diagnostic confidence was averaged from the three reader's scores. Anterior labral tears were effectively detected with sensitivities of 89% and 96% and specificities of 96% and 100% (P<0.0001) for the 2D and 3D studies, respectively. For posterior labral tears, the sensitivity and specificity of the 2D method were 47% and 98%, respectively. The sensitivity and specificity of the 3D volume sequence were 53% and 98%, respectively. The lower sensitivity of both imaging methods for detecting posterior labral tears may be influenced by the smaller number (n=5) of arthroscopically confirmed cases in our study and reflects the difficulty of visualizing the posteroinferior borders of the GLC with present MRI techniques. (orig.)

  15. Noninvasive, three-dimensional full-field body sensor for surface deformation monitoring of human body in vivo.

    Science.gov (United States)

    Chen, Zhenning; Shao, Xinxing; He, Xiaoyuan; Wu, Jialin; Xu, Xiangyang; Zhang, Jinlin

    2017-09-01

    Noninvasive, three-dimensional (3-D), full-field surface deformation measurements of the human body are important for biomedical investigations. We proposed a 3-D noninvasive, full-field body sensor based on stereo digital image correlation (stereo-DIC) for surface deformation monitoring of the human body in vivo. First, by applying an improved water-transfer printing (WTP) technique to transfer optimized speckle patterns onto the skin, the body sensor was conveniently and harmlessly fabricated directly onto the human body. Then, stereo-DIC was used to achieve 3-D noncontact and noninvasive surface deformation measurements. The accuracy and efficiency of the proposed body sensor were verified and discussed by considering different complexions. Moreover, the fabrication of speckle patterns on human skin, which has always been considered a challenging problem, was shown to be feasible, effective, and harmless as a result of the improved WTP technique. An application of the proposed stereo-DIC-based body sensor was demonstrated by measuring the pulse wave velocity of human carotid artery. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  16. Three-dimensional viewing and dosimetric calculations of Au-198 implants of the prostate

    International Nuclear Information System (INIS)

    Avizonis, V.N.; Anderson, K.M.; Jani, S.K.; Hussey, D.H.

    1991-01-01

    Dose gradients for brachytherapy vary considerably in three dimensions, which complicates conventional two-dimensional dosimetry. Recent developments in computer graphics technology have enabled visualization of anatomy and radiation doses in three dimensions. The objective of this paper is to develop a three-dimensional viewing and dosimetry program for brachytherapy and to test this system in phantoms and in patients undergoing Au-198 implants in the prostate. Three-dimensional computer algorithms for the author's Silicon Graphics supercomputing workstation were developed, tested, and modified on the basis of studies in phantoms and patients. Studies were performed on phantoms of known dimensions and gold seeds in known locations to assess the accuracy of volume reconstruction, seed placement, and isodose distribution. Isodose curves generated with the three-dimensional system were compared with those generated by a Theratronics Treatment Planning Computer using conventional methods. Twenty patients with permanent Au-198 interstitial implants in the prostate were similarly studied

  17. Three-dimensional brain mapping using fMRI

    International Nuclear Information System (INIS)

    Fukunaga, Masaki; Tanaka, Chuzo; Umeda, Masahiro; Ebisu, Toshihiko; Aoki, Ichio; Higuchi, Toshihiro; Naruse, Shoji.

    1997-01-01

    Functional mapping of the activated brain, the location and extent of the activated area were determined, during motor tasks and sensory stimulation using fMRI superimposed on 3D anatomical MRI. Twelve volunteers were studied. The fMR images were acquired using a 2D gradient echo echo planar imaging sequence. The 3D anatomical MR images of the whole brain were acquired using a conventional 3D gradient echo sequence. Motor tasks were sequential opposition of fingers, clenching a hand and elbow flexion. Somatosensory stimulation were administered by scrubbing the palm and sole with a washing sponge. Visual stimulation consisted of full visual field stimulation. Data were analyzed by the cross-correlation method. Transversal fMR images and anatomical images were reconstructed using both volume-, surface-rendering methods, and reconstructed for coronal and sagittal sections. Activated areas were expressed using the three primary colors. Motor tasks activated the contralateral primary motor area (M1), the primary somatosensory area (S1) and the supplementary motor area (SMA). Somatosensory tasks activated the contralateral S1, M1 and secondary sensory area (S2). Activated areas during full visual field stimulation was observed in the bilateral occipital lobe, including both the primary cortex. Three-dimensional brain mapping allowed visualization of the anatomical location and extent of the activated brain during both motor task and sensory stimulation. Using this method we could obtain a functional map similar to the Penfield's schema. (author)

  18. A novel three-dimensional mesh deformation method based on sphere relaxation

    International Nuclear Information System (INIS)

    Zhou, Xuan; Li, Shuixiang

    2015-01-01

    In our previous work (2013) [19], we developed a disk relaxation based mesh deformation method for two-dimensional mesh deformation. In this paper, the idea of the disk relaxation is extended to the sphere relaxation for three-dimensional meshes with large deformations. We develop a node based pre-displacement procedure to apply initial movements on nodes according to their layer indices. Afterwards, the nodes are moved locally by the improved sphere relaxation algorithm to transfer boundary deformations and increase the mesh quality. A three-dimensional mesh smoothing method is also adopted to prevent the occurrence of the negative volume of elements, and further improve the mesh quality. Numerical applications in three-dimension including the wing rotation, bending beam and morphing aircraft are carried out. The results demonstrate that the sphere relaxation based approach generates the deformed mesh with high quality, especially regarding complex boundaries and large deformations

  19. A novel three-dimensional mesh deformation method based on sphere relaxation

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Xuan [Department of Mechanics & Engineering Science, College of Engineering, Peking University, Beijing, 100871 (China); Institute of Applied Physics and Computational Mathematics, Beijing, 100094 (China); Li, Shuixiang, E-mail: lsx@pku.edu.cn [Department of Mechanics & Engineering Science, College of Engineering, Peking University, Beijing, 100871 (China)

    2015-10-01

    In our previous work (2013) [19], we developed a disk relaxation based mesh deformation method for two-dimensional mesh deformation. In this paper, the idea of the disk relaxation is extended to the sphere relaxation for three-dimensional meshes with large deformations. We develop a node based pre-displacement procedure to apply initial movements on nodes according to their layer indices. Afterwards, the nodes are moved locally by the improved sphere relaxation algorithm to transfer boundary deformations and increase the mesh quality. A three-dimensional mesh smoothing method is also adopted to prevent the occurrence of the negative volume of elements, and further improve the mesh quality. Numerical applications in three-dimension including the wing rotation, bending beam and morphing aircraft are carried out. The results demonstrate that the sphere relaxation based approach generates the deformed mesh with high quality, especially regarding complex boundaries and large deformations.

  20. Three-dimensional quantitation of pediatric tumor bulk

    International Nuclear Information System (INIS)

    Eggli, K.D.; Close, P.; Dillon, P.W.; Umlauf, M.; Hopper, K.D.

    1995-01-01

    Will 3-dimensional (3-D) volumetric determination improve our ability to assess tumor response to therapy? Forty-five CT scans of pediatric patients with unresectable thoracic or abdominal neoplasia were assessed for tumor bulk by the standard ''2-dimensional (2-D)'' volume formula (cross-sectional areaxlength) and by 3-D volumetric analysis. Thirty-two examinations were performed in follow-up, and percent change in tumor size was calculated. The 2-D volume calculation overestimated tumor volume by more than 50% on all but two examinations when the 2-D volume was compared with the 3-D volume. In 28% of follow-up examinations, the 2-D calculation of percent change differed by more than 10% from the 3-D volume. Fifteen percent differed by over 25%. This changed the response category of one patient from ''no response'' to ''partial response''. 3-D volumetric analysis, give more accurate assessment of the actual tumor bulk and its subsequent changes in size in response to therapy. (orig.)

  1. Volume fraction dependence of transient absorption signal and nonlinearities in metal nanocolloids

    International Nuclear Information System (INIS)

    Jayabalan, J; Singh, Asha; Khan, Salahuddin; Chari, Rama

    2013-01-01

    Electron–lattice thermalization dynamics in metal nanoparticles or in bulk metal is usually estimated by measuring the decay time of the change in transmission following an optical excitation. Such measurements can be performed in transient absorption geometry using a femtosecond laser. We find that for silver nanoplatelet/water colloids, the decay time of the transient absorption depends on the volume fraction of silver in water. By estimating the volume fraction dependence of nonlinearities in the same samples, we show that the variation in the measured decay time is due to pump-depletion effects present in the sample. The correct correction factor for taking into account pump-depletion effects in fifth- and higher-order nonlinearities is also presented. (paper)

  2. Three-dimensional neuroimaging

    International Nuclear Information System (INIS)

    Toga, A.W.

    1990-01-01

    This book reports on new neuroimaging technologies that are revolutionizing the study of the brain be enabling investigators to visualize its structure and entire pattern of functional activity in three dimensions. The book provides a theoretical and practical explanation of the new science of creating three-dimensional computer images of the brain. The coverage includes a review of the technology and methodology of neuroimaging, the instrumentation and procedures, issues of quantification, analytic protocols, and descriptions of neuroimaging systems. Examples are given to illustrate the use of three-dimensional enuroimaging to quantitate spatial measurements, perform analysis of autoradiographic and histological studies, and study the relationship between brain structure and function

  3. Control of operational transients in power reactors - Methodology

    International Nuclear Information System (INIS)

    Vukovic, D.

    1983-01-01

    By introducing the nuclear power stations in the electric power system, questions of their possibilities to satisfy system's demand arise. Control of operational transients (temperature and Xe 135 ) in power reactors by determining the optimal control rod strategy is given. Ti optimize the Xe 135 transients, the Pantryagin theorem of optimal processes is applied. For solving three dimensional, two-group diffusion equations the heterogeneous Feinberg-Galanin method with axial flux harmonics is adopted. An application of this formalism to three-dimensional, finite cylindrical pressurised water reactor radially reflected is presented. (author)

  4. A control volume scheme for three-dimensional transport: buffer and matrix effect on a decay chain transport in the repository

    International Nuclear Information System (INIS)

    Lee, Y. M.; Hwang, Y. S.; Kim, S. G.; Kang, C. H.

    2002-01-01

    Using a three-dimensional numerical code, B3R developed for nuclide transport of an arbitrary length of decay chain in the buffer between the canister and adjacent rock in a high-level radioactive waste repository by adopting a finite difference method utilizing the control-volume scheme, some illustrative calculations have been done. A linear sorption isotherm, nuclide transport due to diffusion in the buffer and the rock matrix, and advection and dispersion along thin rigid parallel fractures existing in a saturated porous rock matrix as well as diffusion through the fracture wall into the matrix is assumed. In such kind of repository, buffer and rock matrix are known to be important physico-chemical barriers in nuclide retardation. To show effects of buffer and rock matrix on nuclide transport in HLW repository and also to demonstrate usefulness of B3R, several cases of breakthrough curves as well as three-dimensional plots of concentration isopleths associated with these two barriers are introduced for a typical case of decay chain of 234 U→ 230 Th→ 226 Ra, which is the most important chain as far as the human environment is concerned

  5. Calculation of three-dimensional fluid flow with multiple free surfaces

    International Nuclear Information System (INIS)

    Vander Vorst, M.J.; Chan, R.K.C.

    1978-01-01

    This paper presents a method for computing incompressible fluid flows with multiple free surfaces which are not restricted in their orientation. The method is presented in the context of the three-dimensional flow in a Mark I reactor pressure suppression system immediately following a postulated loss of coolant accident. The assumption of potential flow is made. The numerical method is a mixed Eulerian-Lagrangian formulation with the interior treated as Eulerian and the free surfaces as Lagrangian. The accuracy of solution hinges on the careful treatment of two important aspects. First, the Laplace equation for the potential is solved at interior points of the Eulerian finite difference mesh using a three-dimensional ''irregular star'' so that boundary conditions can be imposed at the exact position of the free surface. Second, the Lagrangian free surfaces are composed of triangular elements, upon each vertex of which is applied the fully nonlinear Bernoulli equation. One result of these calculations is the transient load on the suppression vessel during the vent clearing and bubble formation events of a loss of coolant accident

  6. Three Dimensional Energy Transmitting Boundary in the Time Domain

    Directory of Open Access Journals (Sweden)

    Naohiro eNakamura

    2015-11-01

    Full Text Available Although the energy transmitting boundary is accurate and efficient for the FEM earthquake response analysis, it could be applied in the frequency domain only. In the previous papers, the author proposed an earthquake response analysis method using the time domain energy transmitting boundary for two dimensional problems. In this paper, this technique is expanded for three dimensional problems. The inner field is supposed to be a hexahedron shape and the approximate time domain boundary is explained, first. Next, two dimensional anti-plane time domain boundary is studied for a part of the approximate three dimensional boundary method. Then, accuracy and efficiency of the proposed method are confirmed by example problems.

  7. Three-Dimensional Elasticity Solutions for Sound Radiation of Functionally Graded Materials Plates considering State Space Method

    Directory of Open Access Journals (Sweden)

    Tieliang Yang

    2016-01-01

    Full Text Available This paper presents an analytical study for sound radiation of functionally graded materials (FGM plate based on the three-dimensional theory of elasticity. The FGM plate is a mixture of metal and ceramic, and its material properties are assumed to have smooth and continuous variation in the thickness direction according to a power-law distribution in terms of volume fractions of the constituents. Based on the three-dimensional theory of elasticity and state space method, the governing equations with variable coefficients of the FGM plate are derived. The sound radiation of the vibration plate is calculated with Rayleigh integral. Comparisons of the present results with those of solutions in the available literature are made and good agreements are achieved. Finally, some parametric studies are carried out to investigate the sound radiation properties of FGM plates.

  8. Three-dimensional seismic analysis for spent fuel storage rack

    International Nuclear Information System (INIS)

    Lee, Gyu Mahn; Kim, Kang Soo; Park, Keun Bae; Park, Jong Kyun

    1998-01-01

    Time history analysis is usually performed to characterize the nonlinear seismic behavior of a spent fuel storage rack (SFSR). In the past, the seismic analyses of the SFSR were performed with two-dimensional planar models, which could not account for torsional response and simultaneous multi-directional seismic input. In this study, three-dimensional seismic analysis methodology is developed for the single SFSR using the ANSY code. The 3-D model can be used to determine the nonlinear behavior of the rack, i.e., sliding, uplifting, and impact evaluation between the fuel assembly and rack, and rack and the pool wall. This paper also reviews the 3-D modeling of the SFSR and the adequacy of the ANSYS for the seismic analysis. As a result of the adequacy study, the method of ANSYS transient analysis with acceleration time history is suitable for the seismic analysis of highly nonlinear structure such as an SFSR but it isn't appropriate to use displacement time history of seismic input. (author)

  9. The current status of the three-dimensional ultrasonography in gyneaecology

    Energy Technology Data Exchange (ETDEWEB)

    Ong, Chiou Li [Dept. of Diagnostic and Interventional Imaging, KK Women' s and Children' s Hospital, Singapore (Singapore)

    2016-01-15

    Ultrasonography (US) is the most recent cross-sectional imaging modality to acquire three-dimensional (3D) capabilities. The reconstruction of volumetric US data for multiplanar display took a significantly longer time to develop in comparison with computed tomography and magnetic resonance imaging. The current equipment for 3D-US is capable of producing high-resolution images in three different planes, including real-time surface-rendered images. The use of 3D-US in gynaecology was accelerated through the development of the endovaginal volume transducer, which allows the automated acquisition of volumetric US data. Although initially considered an adjunct to two-dimensional US, 3D-US is now the imaging modality of choice for the assessment of Müllerian duct anomalies and the location of intrauterine devices.

  10. Three-dimensional transesophageal echocardiography of the atrial septal defects

    Directory of Open Access Journals (Sweden)

    Romero-Cárdenas Ángel

    2008-07-01

    Full Text Available Abstract Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophageal echocardiography in a spectrum of atrial septal defects by comparing them with representative anatomic specimens.

  11. A three-dimensional X-ray diffraction microscope for deformation studies of polycrystals

    DEFF Research Database (Denmark)

    Fæster Nielsen, Søren; Lauridsen, E.M.; Juul Jensen, D.

    2001-01-01

    -dimensional X-ray diffraction (3DXRD) microscope installed at the European Synchrotron Radiation Facility in Grenoble provides a fast and non-destructive technique for mapping the embedded grains within thick samples in three dimensions. All essential features like the position, volume, orientation, stress...

  12. Three dimensional force prediction in a model linear brushless dc motor

    Energy Technology Data Exchange (ETDEWEB)

    Moghani, J.S.; Eastham, J.F.; Akmese, R.; Hill-Cottingham, R.J. (Univ. of Bath (United Kingdom). School of Electronic and Electric Engineering)

    1994-11-01

    Practical results are presented for the three axes forces produced on the primary of a linear brushless dc machine which is supplied from a three-phase delta-modulated inverter. Conditions of both lateral alignment and lateral displacement are considered. Finite element analysis using both two and three dimensional modeling is compared with the practical results. It is shown that a modified two dimensional model is adequate, where it can be used, in the aligned position and that the full three dimensional method gives good results when the machine is axially misaligned.

  13. Exhaust gas recirculation – Zero dimensional modelling and characterization for transient diesel combustion control

    International Nuclear Information System (INIS)

    Asad, Usman; Tjong, Jimi; Zheng, Ming

    2014-01-01

    Highlights: • Zero-dimensional EGR model for transient diesel combustion control. • Detailed analysis of EGR effects on intake, cylinder charge and exhaust properties. • Intake oxygen validated as an operating condition-independent measure of EGR. • Quantified EGR effectiveness in terms of NOx emission reduction. • Twin lambda sensor technique for estimation of EGR/in-cylinder parameters. - Abstract: The application of exhaust gas recirculation (EGR) during transient engine operation is a challenging task since small fluctuations in EGR may cause larger than acceptable spikes in NOx/soot emissions or deterioration in the combustion efficiency. Moreover, the intake charge dilution at any EGR ratio is a function of engine load and intake pressure, and typically changes during transient events. Therefore, the management of EGR during transient engine operation or advanced combustion cycles (that are inherently less stable) requires a fundamental understanding of the transient EGR behaviour and its impact on the intake charge development. In this work, a zero-dimensional EGR model is described to estimate the transient (cycle-by-cycle) progression of EGR and the time (engine cycles) required for its stabilization. The model response is tuned to a multi-cylinder engine by using an overall engine system time-constant and shown to effectively track the transient EGR changes. The impact of EGR on the actual air–fuel ratio of the cylinder charge is quantified by defining an in-cylinder excess-air ratio that accounts for the oxygen in the recycled exhaust gas. Furthermore, a twin lambda sensor (TLS) technique is implemented for tracking the intake dilution and in-cylinder excess-air ratio in real-time. The modelling and analysis results are validated against a wide range of engine operations, including transient and steady-state low temperature combustion tests

  14. Assessment of correlation between knee notch width index and the three-dimensional notch volume

    NARCIS (Netherlands)

    van Eck, C.F.; Martins, C.A.Q.; Lorenz, S.G.F.; Fu, F.H.; Smolinski, P.

    2010-01-01

    This study was done to determine whether there is a correlation between the notch volume and the notch width index (NWI) as measured on the three most frequently used radiographic views: the Holmblad 45A degrees, Holmblad 70A degrees, and Rosenberg view. The notch volume of 20 cadaveric knees was

  15. Numerical simulation of three-dimensional unsteady flow in a scroll expander applied in waste heat recovery

    International Nuclear Information System (INIS)

    Song, P P; Wei, M S; Shi, L; Ma, C C

    2013-01-01

    Three-dimensional numerical simulations of a scroll expander were performed with dynamic mesh technology. R245fa was selected as the working fluid in the simulations. The PISO algorithm was applied to solve the governing equations with RNG k-ε turbulent model. The distribution and variation of three-dimensional flow field inside the scroll expander were obtained. The research indicates that the flow field is nonuniform and asymmetrical distributions exist inside the expander. Vortex flows also exist in some working chambers. Dynamic clearance leakage flows and inlet orifice throttling have great effects on the flow field distribution. Transient output torque and the mass flux have periodic fluctuations during the working cycles

  16. Generalized Runge-Kutta method for two- and three-dimensional space-time diffusion equations with a variable time step

    International Nuclear Information System (INIS)

    Aboanber, A.E.; Hamada, Y.M.

    2008-01-01

    An extensive knowledge of the spatial power distribution is required for the design and analysis of different types of current-generation reactors, and that requires the development of more sophisticated theoretical methods. Therefore, the need to develop new methods for multidimensional transient reactor analysis still exists. The objective of this paper is to develop a computationally efficient numerical method for solving the multigroup, multidimensional, static and transient neutron diffusion kinetics equations. A generalized Runge-Kutta method has been developed for the numerical integration of the stiff space-time diffusion equations. The method is fourth-order accurate, using an embedded third-order solution to arrive at an estimate of the truncation error for automatic time step control. In addition, the A(α)-stability properties of the method are investigated. The analyses of two- and three-dimensional benchmark problems as well as static and transient problems, demonstrate that very accurate solutions can be obtained with assembly-sized spatial meshes. Preliminary numerical evaluations using two- and three-dimensional finite difference codes showed that the presented generalized Runge-Kutta method is highly accurate and efficient when compared with other optimized iterative numerical and conventional finite difference methods

  17. Three-dimensional space-time kinetic analysis with CORETRAN and RETRAN-3D of the NEACRP PWR rod ejection benchmark

    Energy Technology Data Exchange (ETDEWEB)

    Ferroukhi, H.; Coddington, P

    2001-03-01

    One of the activities within the STARS project, in the Laboratory for Reactor Physics and System Behaviour; is the development of a coupling methodology between the three-dimensional, space-time kinetics codes CORETRAN and RETRAN-3D in order to perform core and plant transient analyses of the Swiss LWRs. The CORETRAN code is a 3-D full-core simulator, intended to be used for core-related analyses, while RETRAN-3D is the three-dimensional kinetics version of the plant system code RETRAN, and can therefore be used for best-estimate analyses of a wide range of transients in both PWRs and BWRs. Because the neutronics solver in both codes is based on the same kinetics model, one important advantage is that the codes can be coupled so that the initial conditions for a RETRAN-3D plant analysis are generated by a detailed-core, steady-state calculation using CORETRAN. As a first step towards using CORETRAN and RETRAN-3D for kinetic applications, the NEACRP PWR rod ejection benchmark has been analyzed with both codes, and is presented in this paper. The first objective is to verify the consistency between the static and kinetic solutions of the two codes, and so gain confidence in the coupling methodology. The second objective is to assess the CORETRAN and RETRAN-3D solutions for a well-defined RIA transient, comparing with previously published results. In parallel, several sensitivity studies have been performed in an attempt to identify models and calculational options important for a correct analysis of an RIA event in a LWR using these two codes. (author)

  18. Three-dimensional evaluation of pharyngeal airway in individuals with varying growth patterns using cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Rohan Diwakar

    2015-01-01

    Full Text Available Introduction: The purpose of this study was to evaluate the pharyngeal airway volume in individuals with different vertical growth patterns. Methods: Cone beam computed tomography scans were evaluated of 40 subjects with the age range from 14 to 25 years and were divided into three groups. Horizontal growers consisted of 13 subjects, normal growers consisted of 14 subjects, and the vertical growers consisted of 13 subjects. The pharyngeal airway volume was measured using In Vivo Dental 5.1 software (Anatomage, Anatomy Imaging Software, San Jose, CA, USA. Results: The results obtained were analyzed statistically. The statistical test used for the analysis of the result was Student′s t-test. The independent t-test was done to compare the mean of the pharyngeal airway between the normal growers and horizontal growers and between the normal growers and the vertical growers. No statistically significant difference between the three groups was found in the volumetric measurements of the various sections of airway. Conclusions: Pharyngeal airway volume does not differ significantly in different vertical jaw relationships. It was possible to evaluate the pharyngeal airway volume three dimensionally.

  19. Three-dimensional reconstruction of the giant mimivirus particle with an x-ray free-electron laser.

    Science.gov (United States)

    Ekeberg, Tomas; Svenda, Martin; Abergel, Chantal; Maia, Filipe R N C; Seltzer, Virginie; Claverie, Jean-Michel; Hantke, Max; Jönsson, Olof; Nettelblad, Carl; van der Schot, Gijs; Liang, Mengning; DePonte, Daniel P; Barty, Anton; Seibert, M Marvin; Iwan, Bianca; Andersson, Inger; Loh, N Duane; Martin, Andrew V; Chapman, Henry; Bostedt, Christoph; Bozek, John D; Ferguson, Ken R; Krzywinski, Jacek; Epp, Sascha W; Rolles, Daniel; Rudenko, Artem; Hartmann, Robert; Kimmel, Nils; Hajdu, Janos

    2015-03-06

    We present a proof-of-concept three-dimensional reconstruction of the giant mimivirus particle from experimentally measured diffraction patterns from an x-ray free-electron laser. Three-dimensional imaging requires the assembly of many two-dimensional patterns into an internally consistent Fourier volume. Since each particle is randomly oriented when exposed to the x-ray pulse, relative orientations have to be retrieved from the diffraction data alone. We achieve this with a modified version of the expand, maximize and compress algorithm and validate our result using new methods.

  20. A parallel finite-volume finite-element method for transient compressible turbulent flows with heat transfer

    International Nuclear Information System (INIS)

    Masoud Ziaei-Rad

    2010-01-01

    In this paper, a two-dimensional numerical scheme is presented for the simulation of turbulent, viscous, transient compressible flows in the simultaneously developing hydraulic and thermal boundary layer region. The numerical procedure is a finite-volume-based finite-element method applied to unstructured grids. This combination together with a new method applied for the boundary conditions allows for accurate computation of the variables in the entrance region and for a wide range of flow fields from subsonic to transonic. The Roe-Riemann solver is used for the convective terms, whereas the standard Galerkin technique is applied for the viscous terms. A modified κ-ε model with a two-layer equation for the near-wall region combined with a compressibility correction is used to predict the turbulent viscosity. Parallel processing is also employed to divide the computational domain among the different processors to reduce the computational time. The method is applied to some test cases in order to verify the numerical accuracy. The results show significant differences between incompressible and compressible flows in the friction coefficient, Nusselt number, shear stress and the ratio of the compressible turbulent viscosity to the molecular viscosity along the developing region. A transient flow generated after an accidental rupture in a pipeline was also studied as a test case. The results show that the present numerical scheme is stable, accurate and efficient enough to solve the problem of transient wall-bounded flow.

  1. Three dimensional canonical transformations

    International Nuclear Information System (INIS)

    Tegmen, A.

    2010-01-01

    A generic construction of canonical transformations is given in three-dimensional phase spaces on which Nambu bracket is imposed. First, the canonical transformations are defined as based on cannonade transformations. Second, it is shown that determination of the generating functions and the transformation itself for given generating function is possible by solving correspondent Pfaffian differential equations. Generating functions of type are introduced and all of them are listed. Infinitesimal canonical transformations are also discussed as the complementary subject. Finally, it is shown that decomposition of canonical transformations is also possible in three-dimensional phase spaces as in the usual two-dimensional ones.

  2. Preliminary evaluation of foetal liver volume by three-dimensional ultrasound in women with gestational diabetes mellitus.

    Science.gov (United States)

    İlhan, Gülşah; Gültekin, Hüseyin; Kubat, Ayça; Gokmen Karasu, Ayse Filiz; Güngör, Emre Sinan; Zebitay, Galip Ali; Verit Atmaca, Fatma Ferda

    2018-03-19

    The aim of the study was to assess the standard foetal biometric measurements and foetal liver volume (FLV) in pregnancies complicated by gestational diabetes mellitus (GDM) at the time of GDM screening and to compare the results with foetuses in normal pregnancies. Ninety-seven pregnant women with normal singleton uncomplicated pregnancies between 24 and 28 weeks of gestation were allocated into GDM (+) (n: 33) and GDM (-) (n: 64) groups based on their 75 g oral glucose tolerance test results. Foetal biometric measurements and FLV measurements of the groups were compared. Although there were no significant differences in the standard biometric measurements between the two groups, FLV was significantly higher in the women with GDM (p liver length and foetal liver volume (FLV) have been evaluated as ultrasound parameters of glycaemic control. While the evaluation of foetal liver dimensions has a role in identifying foetal growth acceleration, previous studies addressed patients with insulin-dependent diabetes mellitus rather than gestational diabetes mellitus, utilised two-dimensional ultrasound and did not argue the diagnostic value of these findings. What do the results of this study add? In our study, besides the standard biometric measurements, the FLV measurements were evaluated by a three-dimensional ultrasound. Although there were no significant differences in the standard biometric measurements between the GDM (+) and GDM (-) groups, the FLV was significantly higher in women with GDM. The FLV was found to be a potential predictive factor for GDM. The ROC analysis implied that as a cut-off value of FLV of 32.72 cm 3 for GDM prediction, the sensitivity was 78.8% and the specificity was 56.3%. What are the implications of these findings for clinical practise and/or further research? Screening for GDM with oral glucose tolerance test within the limited weeks of gestation may not always be feasible. On the other hand, the mid-trimester ultrasound scanning

  3. Three-dimensional cinematography with control object of unknown shape.

    Science.gov (United States)

    Dapena, J; Harman, E A; Miller, J A

    1982-01-01

    A technique for reconstruction of three-dimensional (3D) motion which involves a simple filming procedure but allows the deduction of coordinates in large object volumes was developed. Internal camera parameters are calculated from measurements of the film images of two calibrated crosses while external camera parameters are calculated from the film images of points in a control object of unknown shape but at least one known length. The control object, which includes the volume in which the activity is to take place, is formed by a series of poles placed at unknown locations, each carrying two targets. From the internal and external camera parameters, and from locations of the images of point in the films of the two cameras, 3D coordinates of the point can be calculated. Root mean square errors of the three coordinates of points in a large object volume (5m x 5m x 1.5m) were 15 mm, 13 mm, 13 mm and 6 mm, and relative errors in lengths averaged 0.5%, 0.7% and 0.5%, respectively.

  4. Reliability of three-dimensional sonographic measurements in early pregnancy using virtual reality

    NARCIS (Netherlands)

    C.M. Verwoerd-Dikkeboom (Christine); A.H.J. Koning (Anton); W.C.J. Hop (Wim); M. Rousian (Melek); P.J. van der Spek (Peter); N. Exalto (Niek); R.P.M. Steegers-Theunissen (Régine)

    2008-01-01

    textabstractObjective: To establish the reliability of three-dimensional (3D) ultrasound measurements in early pregnancy using a virtual reality system (the Barco I-Space). Methods: The study included 28 pregnancies with gestational ages ranging from 6 to 14 (median, 10) weeks. 3D volumes were

  5. Three-Dimensional Flow Behavior Inside the Submerged Entry Nozzle

    Science.gov (United States)

    Real-Ramirez, Cesar Augusto; Carvajal-Mariscal, Ignacio; Sanchez-Silva, Florencio; Cervantes-de-la-Torre, Francisco; Diaz-Montes, Jesus; Gonzalez-Trejo, Jesus

    2018-05-01

    According to various authors, the surface quality of steel depends on the dynamic conditions that occur within the continuous casting mold's upper region. The meniscus, found in that upper region, is where the solidification process begins. The liquid steel is distributed into the mold through a submerged entry nozzle (SEN). In this paper, the dynamic behavior inside the SEN is analyzed by means of physical experiments and numerical simulations. The particle imaging velocimetry technique was used to obtain the vector field in different planes and three-dimensional flow patterns inside the SEN volume. Moreover, large eddy simulation was performed, and the turbulence model results were used to understand the nonlinear flow pattern inside the SEN. Using scaled physical and numerical models, quasi-periodic behavior was observed due to the interaction of two three-dimensional vortices that move inside the SEN lower region located between the exit ports of the nozzle.

  6. Programmable full-adder computations in communicating three-dimensional cell cultures.

    Science.gov (United States)

    Ausländer, David; Ausländer, Simon; Pierrat, Xavier; Hellmann, Leon; Rachid, Leila; Fussenegger, Martin

    2018-01-01

    Synthetic biologists have advanced the design of trigger-inducible gene switches and their assembly into input-programmable circuits that enable engineered human cells to perform arithmetic calculations reminiscent of electronic circuits. By designing a versatile plug-and-play molecular-computation platform, we have engineered nine different cell populations with genetic programs, each of which encodes a defined computational instruction. When assembled into 3D cultures, these engineered cell consortia execute programmable multicellular full-adder logics in response to three trigger compounds.

  7. Three-dimensional microbubble streaming flows

    Science.gov (United States)

    Rallabandi, Bhargav; Marin, Alvaro; Rossi, Massimiliano; Kaehler, Christian; Hilgenfeldt, Sascha

    2014-11-01

    Streaming due to acoustically excited bubbles has been used successfully for applications such as size-sorting, trapping and focusing of particles, as well as fluid mixing. Many of these applications involve the precise control of particle trajectories, typically achieved using cylindrical bubbles, which establish planar flows. Using astigmatic particle tracking velocimetry (APTV), we show that, while this two-dimensional picture is a useful description of the flow over short times, a systematic three-dimensional flow structure is evident over long time scales. We demonstrate that this long-time three-dimensional fluid motion can be understood through asymptotic theory, superimposing secondary axial flows (induced by boundary conditions at the device walls) onto the two-dimensional description. This leads to a general framework that describes three-dimensional flows in confined microstreaming systems, guiding the design of applications that profit from minimizing or maximizing these effects.

  8. Creating three-dimensional thermal maps

    CSIR Research Space (South Africa)

    Price

    2011-11-01

    Full Text Available stream_source_info Price_2011.pdf.txt stream_content_type text/plain stream_size 30895 Content-Encoding ISO-8859-1 stream_name Price_2011.pdf.txt Content-Type text/plain; charset=ISO-8859-1 Creating Three...-Dimensional Thermal Maps Mathew Price Cogency cc Cape Town Email: mathew@cogency.co.za Jeremy Green CSIR Centre for Mining Innovation Johannesburg Email: jgreen@csir.co.za John Dickens CSIR Centre for Mining Innovation Johannesburg Email: jdickens...

  9. Three dimensional analysis of coelacanth body structure by computer graphics and X-ray CT images

    International Nuclear Information System (INIS)

    Suzuki, Naoki; Hamada, Takashi.

    1990-01-01

    Three dimensional imaging processes were applied for the structural and functional analyses of the modern coelacanth (Latimeria chalumnae). Visualization of the obtained images is performed with computer graphics on the basis of serial images by an X-ray CT scanning method. Reconstruction of three dimensional images of the body structure of coelacanth using the volume rendering and surface rendering methods provides us various information about external and internal shapes of this exquisite fish. (author)

  10. Assessing anthropogenic impacts on limited water resources under semi-arid conditions: three-dimensional transient regional modelling in Jordan

    Science.gov (United States)

    Rödiger, Tino; Magri, Fabien; Geyer, Stefan; Morandage, Shehan Tharaka; Ali Subah, H. E.; Alraggad, Marwan; Siebert, Christian

    2017-11-01

    Both increasing aridity and population growth strongly stress freshwater resources in semi-arid areas such as Jordan. The country's second largest governorate, Irbid, with over 1 million inhabitants, is already suffering from an annual water deficit of 25 million cubic meters (MCM). The population is expected to double within the next 20 years. Even without the large number of refugees from Syria, the deficit will likely increase to more then 50 MCM per year by 2035 The Governorate's exclusive resource is groundwater, abstracted by the extensive Al Arab and Kufr Asad well fields. This study presents the first three-dimensional transient regional groundwater flow model of the entire Wadi al Arab to answer important questions regarding the dynamic quality and availability of water within the catchment. Emphasis is given to the calculation and validation of the dynamic groundwater recharge, derived from a multi-proxy approach, including (1) a hydrological model covering a 30-years dataset, (2) groundwater level measurements and (3) information about springs. The model enables evaluation of the impact of abstraction on the flow regime and the groundwater budget of the resource. Sensitivity analyses of controlling parameters indicate that intense abstraction in the southern part of the Wadi al Arab system can result in critical water-level drops of 10 m at a distance of 16 km from the production wells. Moreover, modelling results suggest that observed head fluctuations are strongly controlled by anthropogenic abstraction rather than variable recharge rates due to climate changes.

  11. CT two-dimensional reformation versus three-dimensional volume rendering with regard to surgical findings in the preoperative assessment of the ossicular chain in chronic suppurative otitis media

    International Nuclear Information System (INIS)

    Guo, Yong; Liu, Yang; Lu, Qiao-hui; Zheng, Kui-hong; Shi, Li-jing; Wang, Qing-jun

    2013-01-01

    Purpose: To assess the role of three-dimensional volume rendering (3DVR) in the preoperative assessment of the ossicular chain in chronic suppurative otitis media (CSOM). Materials and methods: Sixty-six patients with CSOM were included in this prospective study. Temporal bone was scanned with a 128-channel multidetector row CT and the axial data was transferred to the workstation for multiplanar reformation (MPR) and 3DVR reconstructions. Evaluation of the ossicular chain according to a three-point scoring system on two-dimensional reformation (2D) and 3DVR was performed independently by two radiologists. The evaluation results were compared with surgical findings. Results: 2D showed over 89% accuracy in the assessment of segmental absence of the ossicular chain in CSOM, no matter how small the segmental size was. 3DVR was as accurate as 2D for the assessment of segmental absence. However, 3DVR was found to be more accurate than 2D in the evaluation of partial erosion of segments. Conclusion: Both 3DVR and 2D are accurate and reliable for the assessment of the ossicular chain in CSOM. The inclusion of 3DVR images in the imaging protocol improves the accuracy of 2D in detecting ossicular erosion from CSOM

  12. CT two-dimensional reformation versus three-dimensional volume rendering with regard to surgical findings in the preoperative assessment of the ossicular chain in chronic suppurative otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yong, E-mail: guoyong27@hotmail.com [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Liu, Yang, E-mail: liuyangdoc@sina.com [Department of Otorhinolaryngology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Lu, Qiao-hui, E-mail: Luqiaohui465@126.com [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Zheng, Kui-hong, E-mail: zhengkuihong1971@sina.com [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Shi, Li-jing, E-mail: Shilijing2003@yahoo.com.cn [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China); Wang, Qing-jun, E-mail: wangqingjun77@163.com [Department of Radiology, Navy General Hospital, 6# Fucheng Road, Beijing 100048 (China)

    2013-09-15

    Purpose: To assess the role of three-dimensional volume rendering (3DVR) in the preoperative assessment of the ossicular chain in chronic suppurative otitis media (CSOM). Materials and methods: Sixty-six patients with CSOM were included in this prospective study. Temporal bone was scanned with a 128-channel multidetector row CT and the axial data was transferred to the workstation for multiplanar reformation (MPR) and 3DVR reconstructions. Evaluation of the ossicular chain according to a three-point scoring system on two-dimensional reformation (2D) and 3DVR was performed independently by two radiologists. The evaluation results were compared with surgical findings. Results: 2D showed over 89% accuracy in the assessment of segmental absence of the ossicular chain in CSOM, no matter how small the segmental size was. 3DVR was as accurate as 2D for the assessment of segmental absence. However, 3DVR was found to be more accurate than 2D in the evaluation of partial erosion of segments. Conclusion: Both 3DVR and 2D are accurate and reliable for the assessment of the ossicular chain in CSOM. The inclusion of 3DVR images in the imaging protocol improves the accuracy of 2D in detecting ossicular erosion from CSOM.

  13. BACCHUS-3D/SP. A computer programme for the three-dimensional description of sodium single-phase flow in bundle geometry

    International Nuclear Information System (INIS)

    Bottoni, M.; Dorr, B.; Homann, C.; Struwe, D.

    1983-07-01

    The computer programme BACCHUS implemented at KfK includes a steady-state version, a two-dimensional and a three-dimensional transient single-phase flow version describing the thermal-hydraulic behaviour of the coolant (sodium or water) in bundle geometry under nominal or accident conditions. All versions are coupled with a pin model describing the temperature distribution in fuel (or electrical heaters) and cladding. The report describes the programme from the viewpoints of the geometrical model, the mathematical foundations and the numerical treatment of the basic equations. Although emphasis is put on the three-dimensional version, the two-dimensional and the steady state versions are also documented in self-consistent sections. (orig.) [de

  14. Three-dimensional computed tomographic angiography to predict weight and volume of deep inferior epigastric artery perforator flap for breast reconstruction.

    Science.gov (United States)

    Rosson, Gedge D; Shridharani, Sachin M; Magarakis, Michael; Manahan, Michele A; Stapleton, Sahael M; Gilson, Marta M; Flores, Jaime I; Basdag, Basak; Fishman, Elliot K

    2011-10-01

    Three-dimensional computed tomographic angiography (3D CTA) can be used preoperatively to evaluate the course and caliber of perforating blood vessels for abdominal free-flap breast reconstruction. For postmastectomy breast reconstruction, many women inquire whether the abdominal tissue volume will match that of the breast to be removed. Therefore, our goal was to estimate preoperative volume and weight of the proposed flap and compare them with the actual volume and weight to determine if diagnostic imaging can accurately identify the amount of tissue that could potentially to be harvested. Preoperative 3D CTA was performed in 15 patients, who underwent breast reconstruction using the deep inferior epigastric artery perforator flap. Before each angiogram, stereotactic fiducials were placed on the planned flap outline. The radiologist reviewed each preoperative angiogram to estimate the volume, and thus, weight of the flap. These estimated weights were compared with the actual intraoperative weights. The average estimated weight was 99.7% of the actual weight. The interquartile range (25th to 75th percentile), which represents the "middle half" of the patients, was 91-109%, indicating that half of the patients had an estimated weight within 9% of the actual weight; however, there was a large range (70-133%). 3D CTA with stereotactic fiducials allows surgeons to adequately estimate abdominal flap volume before surgery, potentially giving guidance in the amount of tissue that can be harvested from a patient's lower abdomen. Copyright © 2011 Wiley-Liss, Inc.

  15. Three-dimensional graphene networks: synthesis,properties and applications

    Institute of Scientific and Technical Information of China (English)

    Yanfeng Ma; Yongsheng Chen

    2015-01-01

    Recently, three-dimensional graphene/graphene oxide(GO) networks(3DGNs) in the form of foams,sponges and aerogels have atracted much atention. 3D structures provide graphene materials with high speciic surface areas, large pore volumes, strong mechanical strengths and fast mass and electron transport,owing to the combination of the 3D porous structures and the excellent intrinsic properties of graphene.his review focuses on the latest advances in the preparation, properties and potential applications of 3D micro-/nano-architectures made of graphene/GO-based networks, with emphasis on graphene foams and sponges.

  16. Three-dimensional structure of the γ-secretase complex

    International Nuclear Information System (INIS)

    Ogura, Toshihiko; Mio, Kazuhiro; Hayashi, Ikuo; Miyashita, Hiroyuki; Fukuda, Rie; Kopan, Raphael; Kodama, Tatsuhiko; Hamakubo, Takao; Iwastubo, Takeshi; Tomita, Taisuke; Sato, Chikara

    2006-01-01

    γ-Secretase belongs to an atypical class of aspartic proteases that hydrolyzes peptide bonds within the transmembrane domain of substrates, including amyloid-β precursor protein and Notch. γ-Secretase is comprised of presenilin, nicastrin, APH-1, and PEN-2 which form a large multimeric membrane protein complex, the three-dimensional structure of which is unknown. To gain insight into the structure of this complex enzyme, we purified functional γ-secretase complex reconstituted in Sf9 cells and analyzed it using negative stain electron microscopy and 3D reconstruction techniques. Analysis of 2341 negatively stained particle images resulted in the three-dimensional representation of γ-secretase at a resolution of 48 A. The structure occupies a volume of 560 x 320 x 240 A and resembles a flat heart comprised of two oppositely faced, dimpled domains. A low density space containing multiple pores resides between the domains. Some of the dimples in the putative transmembrane region may house the catalytic site. The large dimensions are consistent with the observation that γ-secretase activity resides within a high molecular weight complex

  17. Evaluation of the relationship between extremity soft tissue sarcomas and adjacent major vessels using contrast-enhanced multidetector CT and three-dimensional volume-rendered CT angiography - A preliminary study

    International Nuclear Information System (INIS)

    Li, YangKang; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo; Zheng, Yu; Wei, XiaoLong; Cheng, Ying; Liu, GuoRui

    2013-01-01

    Background: Accurate description of the relationship between extremity soft tissue sarcoma and the adjacent major vessels is crucial for successful surgery. In addition to magnetic resonance imaging (MRI) or in patients who cannot undergo MRI, two-dimensional (2D) postcontrast computed tomography (CT) images and three-dimensional (3D) volume-rendered CT angiography may be valuable alternative imaging techniques for preoperative evaluation of extremity sarcomas. Purpose: To preoperatively assess extremity sarcomas using multidetector CT (MDCT), with emphasis on postcontrast MDCT images and 3D volume-rendered MDCT angiography in evaluating the relationship between tumors and adjacent major vessels. Material and Methods: MDCT examinations were performed on 13 patients with non-metastatic extremity sarcomas. Conventional CT images and 3D volume-rendered CT angiography were evaluated, with focus on the relationship between tumors and adjacent major vessels. Kappa consistency statistics were performed with surgery serving as the reference standard. Results: The relationship between sarcomas and adjacent vessels was described as one of three patterns: proximity, adhesion, and encasement. Proximity was seen in five cases on postcontrast CT images or in eight cases on volume-rendered images. Adhesion was seen in three cases on both postcontrast CT images and volume-rendered images. Encasement was seen in five cases on postcontrast CT images or in two cases on volume-rendered images. Compared to surgical results, postcontrast CT images had 100% sensitivity, 83.3% specificity, 87.5% positive predictive value, 100% negative predictive value, and 92.3% accuracy in the detection of vascular invasion (κ = 0.843, P = 0.002). 3D volume-rendered CT angiography had 71.4% sensitivity, 100% specificity, 100% positive predictive value, 75% negative predictive value, and 84.6% accuracy in the detection of vascular invasion (κ = 0.698, P = 0.008). On volume-rendered images, all cases

  18. Comparison of BWR-6 pressurization transients with one-dimensional and point kinetics

    International Nuclear Information System (INIS)

    Serra, J.M.; Mata, P.; Cronin, J.T.

    1992-01-01

    This paper focuses on the differences between the results of core reload licensing calculations for the BWR-6 plant when performed with a one-dimensional (1-D) versus a point kinetics model. More specifically, the improvement in critical power ratio which would be expected from a change in methods from a point to a 1-D kinetics core wide transient calculation for pressurization transients is investigated. To qualitatively assess critical power ratio (CPR) improvement, core wide transient and hot channel calculations of a generator load rejection with failure of the steam by-pass system and a feedwater controller failure of maximum demand are performed with both, point and 1-D kinetics models in the core wide simulation. Additionally, a sensitivity study on the frequency of power shape function updating in the 1-D kinetics calculation is performed

  19. Three-dimensional analysis of future groundwater flow conditions and contaminant plume transport in the Hanford Site unconfined aquifer system: FY 1996 and 1997 status report

    Energy Technology Data Exchange (ETDEWEB)

    Cole, C.R.; Wurstner, S.K.; Williams, M.D.; Thorne, P.D.; Bergeron, M.P.

    1997-12-01

    A three-dimensional numerical model of groundwater flow and transport, based on the Coupled Fluid Energy, and Solute Transport (CFEST) code, was developed for the Hanford Site to support the Hanford Groundwater Project (HGWP), managed by Pacific Northwest National Laboratory. The model was developed to increase the understanding and better forecast the migration of several contaminant plumes being monitored by the HGWP, and to support the Hanford Site Composite Analysis for low-level waste disposal in the 200-Area Plateau. Recent modeling efforts have focused on continued refinement of an initial version of the three-dimensional model developed in 1995 and its application to simulate future transport of selected contaminant plumes in the aquifer system. This version of the model was updated using a more current version of the CFEST code called CFEST96. Prior to conducting simulations of contaminant transport with the three-dimensional model, a previous steady-state, two-dimensional model of the unconfined aquifer system was recalibrated to 1979 water-table conditions with a statistical inverse method implemented in the CFEST-INV computer code. The results of the recalibration were used to refine the three-dimensional conceptual model and to calibrate it with a conceptualization that preserves the two-dimensional hydraulic properties and knowledge of the aquifer`s three-dimensional properties for the same 1979 water-table conditions. The transient behavior of the three-dimensional flow model was also calibrated by adjusting model storage properties (specific yield) until transient water-table predictions approximated observed water-table elevations between 1979 and 1996.

  20. Three-dimensional analysis of future groundwater flow conditions and contaminant plume transport in the Hanford Site unconfined aquifer system: FY 1996 and 1997 status report

    International Nuclear Information System (INIS)

    Cole, C.R.; Wurstner, S.K.; Williams, M.D.; Thorne, P.D.; Bergeron, M.P.

    1997-12-01

    A three-dimensional numerical model of groundwater flow and transport, based on the Coupled Fluid Energy, and Solute Transport (CFEST) code, was developed for the Hanford Site to support the Hanford Groundwater Project (HGWP), managed by Pacific Northwest National Laboratory. The model was developed to increase the understanding and better forecast the migration of several contaminant plumes being monitored by the HGWP, and to support the Hanford Site Composite Analysis for low-level waste disposal in the 200-Area Plateau. Recent modeling efforts have focused on continued refinement of an initial version of the three-dimensional model developed in 1995 and its application to simulate future transport of selected contaminant plumes in the aquifer system. This version of the model was updated using a more current version of the CFEST code called CFEST96. Prior to conducting simulations of contaminant transport with the three-dimensional model, a previous steady-state, two-dimensional model of the unconfined aquifer system was recalibrated to 1979 water-table conditions with a statistical inverse method implemented in the CFEST-INV computer code. The results of the recalibration were used to refine the three-dimensional conceptual model and to calibrate it with a conceptualization that preserves the two-dimensional hydraulic properties and knowledge of the aquifer's three-dimensional properties for the same 1979 water-table conditions. The transient behavior of the three-dimensional flow model was also calibrated by adjusting model storage properties (specific yield) until transient water-table predictions approximated observed water-table elevations between 1979 and 1996

  1. When treating prostate cancer with three-dimensional conformal radiation therapy the impact of bladder filling status on the volume and integral dose distribution of the target and critical organs should be kept in mind

    International Nuclear Information System (INIS)

    Liu Yueping; Liu Xinfan; Li Yexiong; Guang Ying

    2007-01-01

    Objective: In prostate cancer treated with three-dimensional conformal radiation therapy (3DCRT), we tried to prospectively assess the impact of the filling status of bladder on the volume and the integral dose distribution to the target and surrounding critical organs. Methods: Ten patients with stage T1-T2N0M0 prostate cancer were studied. All patients received 3DCRT to the prostate and inferior seminal vesicle. One hour before CT simulation, the bladder was first voided, and then 400 ml of oral contrast solution was given at every half hour before the CT scan. Urethral catheterization was used for voiding or distending the bladder. When distending the bladder, 250-300 ml of contrast was injected into the bladder with the patient fixed at the supine position. Two sets of transverse images were taken for the whole pelvis in empty and full bladder. After the target and critical organs (bladder, rectum, pelvic small bowel, and femoral heads) were contoured, a treatment plan of three-dimensional conformal radiotherapy was made using the CMS Focus-Xio treatment planning system. The volume and mean doses of CTV, PTV, rectum, bladder, femoral heads, and small bowel with the bladder empty and full were evaluated. The percentage of volume which received 50 Gy in the rectum and bladder, 30 Gy in the femoral heads, and the maximal dose to the pelvic small bowel were also assessed . The variability of volume and dose distribution in these targets or organs was compared between the empty and full bladder status. Results: Comparing to the bladder empty status, full bladder led to a mean increase of 499% in the bladder volume, (67±9) ml and (336±48) ml (P=0.000), respectively. No volume change was found in the CTV, PTV, rectum, femoral heads and pel- vic small bowel(P=0.153,0.501,0.929,0.771,0.081). The mean dose to the bladder in full status was only 35% of that in empty status, (1501±201 ) cGy and (4267±216) cGy(P =0.000), respectively. The mean dose to the pelvic small

  2. TWO- AND THREE-DIMENSIONAL SIMULATIONS OF ASTEROID OCEAN IMPACTS

    Directory of Open Access Journals (Sweden)

    Michael Gittings

    2003-01-01

    Full Text Available We have performed a series of two-dimensional and three-dimensional simulations of asteroid impacts into an ocean using the SAGE code from Los Alamos National Laboratory and Science Applications International Corporation. The SAGE code is a compressible Eulerian hydrodynamics code using continuous adaptive mesh refinement for following discontinuities with a fine grid while treating the bulk of the simulation more coarsely. We have used realistic equations of state for the atmosphere, sea water, the oceanic crust, and the mantle. In two dimensions, we simulated asteroid impactors moving at 20 km/s vertically through an exponential atmosphere into a 5 km deep ocean. The impactors were composed of mantle material (3.32 g/cc or iron (7.8 g/cc with diameters from 250m to 10 km. In our three-dimensional runs we simulated asteroids of 1 km diameter composed of iron moving at 20 km/s at angles of 45 and 60 degrees from the vertical. All impacts, including the oblique ones, produce a large underwater cavities with nearly vertical walls followed by a collapse starting from the bottom and subsequent vertical jetting. Substantial amounts of water are vaporized and lofted high into the atmosphere. In the larger impacts, significant amounts of crustal and even mantle material are lofted as well. Tsunamis up to a kilometer in initial height are generated by the collapse of the vertical jet. These waves are initially complex in form, and interact strongly with shocks propagating through the water and the crust. The tsunami waves are followed out to 100 km from the point of impact. Their periods and wavelengths show them to be intermediate type waves, and not (in general shallow-water waves. At great distances, the waves decay as the inverse of the distance from the impact point, ignoring sea-floor topography. For all impactors smaller than about 2 km diameter, the impacting body is highly fragmented and its remains lofted into the stratosphere with the water

  3. Three-dimensional computer models of electrospinning systems

    Directory of Open Access Journals (Sweden)

    Smółka Krzysztof

    2017-12-01

    Full Text Available Electrospinning is a very interesting method that allows the fabrication of continuous fibers with diameters down to a few nanometers. This paper presents an overview of electrospinning systems as well as their comparison using proposed three-dimensional parameterized numerical models. The presented solutions allow an analysis of the electric field distribution.

  4. Simulation of the Three Mile Island transient in Semiscale

    International Nuclear Information System (INIS)

    Larson, T.K.; Loomis, G.G.; Shumway, R.W.

    1979-07-01

    This report presents the results of a preliminary review and analysis of the data obtained from eight simulations of the Three Mile Island Unit 2 Nuclear Power Generating Station transient (March 28, 1979) that have been conducted in the Semiscale Mod-3 System. The Semiscale simulations of the Three Mile Island (TMI) transient were basically conducted from the same sequence of events as those recorded in the plant. System initial conditions representative of those in the TMI system were established and the transient was initiated by terminating steam generator feedwater and steam valve flow. The steam generator secondaries were drained to control primary to secondary heat transfer. The pressurizer power operated relief valve, pressurizer code safety valve, and core power trip were operated on system pressure. High pressure safety injection was activated for about one minute during the Semiscale simulations. In addition, both primary loop coolant pumps were shut off in the Semiscale simulation at the same time that the Three Mile Island loop 2A pump was shut off

  5. Three-dimensional friction measurement during hip simulation.

    Directory of Open Access Journals (Sweden)

    Robert Sonntag

    Full Text Available Wear of total hip replacements has been the focus of many studies. However, frictional effects, such as high loading on intramodular connections or the interface to the bone, as well as friction associated squeaking have recently increased interest about the amount of friction that is generated during daily activities. The aim of this study was thus to establish and validate a three-dimensional friction setup under standardized conditions.A standard hip simulator was modified to allow for high precision measurements of small frictional effects in the hip during three-dimensional hip articulation. The setup was verified by an ideal hydrostatic bearing and validated with a static-load physical pendulum and an extension-flexion rotation with a dynamic load profile. Additionally, a pendulum model was proposed for screening measurement of frictional effects based on the damping behavior of the angular oscillation without the need for any force/moment transducer. Finally, three-dimensional friction measurements have been realized for ceramic-on-polyethylene bearings of three different sizes (28, 36 and 40 mm.A precision of less than 0.2 Nm during three-dimensional friction measurements was reported, while increased frictional torque (resultant as well as taper torque was measured for larger head diameters. These effects have been confirmed by simple pendulum tests and the theoretical model. A comparison with current literature about friction measurements is presented.This investigation of friction is able to provide more information about a field that has been dominated by the reduction of wear. It should be considered in future pre-clinical testing protocols given by international organizations of standardization.

  6. Three-dimensional coupled kinetics/thermal- hydraulic benchmark TRIGA experiments

    International Nuclear Information System (INIS)

    Feltus, Madeline Anne; Miller, William Scott

    2000-01-01

    This research project provides separate effects tests in order to benchmark neutron kinetics models coupled with thermal-hydraulic (T/H) models used in best-estimate codes such as the Nuclear Regulatory Commission's (NRC) RELAP and TRAC code series and industrial codes such as RETRAN. Before this research project was initiated, no adequate experimental data existed for reactivity initiated transients that could be used to assess coupled three-dimensional (3D) kinetics and 3D T/H codes which have been, or are being developed around the world. Using various Test Reactor Isotope General Atomic (TRIGA) reactor core configurations at the Penn State Breazeale Reactor (PSBR), it is possible to determine the level of neutronics modeling required to describe kinetics and T/H feedback interactions. This research demonstrates that the small compact PSBR TRIGA core does not necessarily behave as a point kinetics reactor, but that this TRIGA can provide actual test results for 3D kinetics code benchmark efforts. This research focused on developing in-reactor tests that exhibited 3D neutronics effects coupled with 3D T/H feedback. A variety of pulses were used to evaluate the level of kinetics modeling needed for prompt temperature feedback in the fuel. Ramps and square waves were used to evaluate the detail of modeling needed for the delayed T/H feedback of the coolant. A stepped ramp was performed to evaluate and verify the derived thermal constants for the specific PSBR TRIGA core loading pattern. As part of the analytical benchmark research, the STAR 3D kinetics code (, STAR: Space and time analysis of reactors, Version 5, Level 3, Users Guide, Yankee Atomic Electric Company, YEAC 1758, Bolton, MA) was used to model the transient experiments. The STAR models were coupled with the one-dimensional (1D) WIGL and LRA and 3D COBRA (, COBRA IIIC: A digital computer program for steady-state and transient thermal-hydraulic analysis of rod bundle nuclear fuel elements, Battelle

  7. Three-dimensional magnetospheric equilibrium with isotropic pressure

    International Nuclear Information System (INIS)

    Cheng, C.Z.

    1995-05-01

    In the absence of the toroidal flux, two coupled quasi two-dimensional elliptic equilibrium equations have been derived to describe self-consistent three-dimensional static magnetospheric equilibria with isotropic pressure in an optimal (Ψ,α,χ) flux coordinate system, where Ψ is the magnetic flux function, χ is a generalized poloidal angle, α is the toroidal angle, α = φ - δ(Ψ,φ,χ) is the toroidal angle, δ(Ψ,φ,χ) is periodic in φ, and the magnetic field is represented as rvec B = ∇Ψ x ∇α. A three-dimensional magnetospheric equilibrium code, the MAG-3D code, has been developed by employing an iterative metric method. The main difference between the three-dimensional and the two-dimensional axisymmetric solutions is that the field-aligned current and the toroidal magnetic field are finite for the three-dimensional case, but vanish for the two-dimensional axisymmetric case. With the same boundary flux surface shape, the two-dimensional axisymmetric results are similar to the three-dimensional magnetosphere at each local time cross section

  8. Three-dimensional MR imaging of the cerebrospinal system with the RARE technique

    International Nuclear Information System (INIS)

    Hennig, J.; Ott, D.; Ylayasski, J.

    1987-01-01

    Three-dimensional RARE myelography is a fast technique for high-resolution imaging of the cerebrospinal fluid. A data set with 1 x 1 x 1-mm resolution can be generated with a 12-minute acquisition time. Sophisticated three-dimensional display algorithms allow reconstruction of planes at arbitrary angles and full three-dimensional displays, which yield extremely useful information for neurosurgical planning. Additionally, the injection of contrast agent can be simulated on the computer and communication pathways between structures of interest can be found noninvasively

  9. (Weakly) three-dimensional caseology

    International Nuclear Information System (INIS)

    Pomraning, G.C.

    1996-01-01

    The singular eigenfunction technique of Case for solving one-dimensional planar symmetry linear transport problems is extended to a restricted class of three-dimensional problems. This class involves planar geometry, but with forcing terms (either boundary conditions or internal sources) which are weakly dependent upon the transverse spatial variables. Our analysis involves a singular perturbation about the classic planar analysis, and leads to the usual Case discrete and continuum modes, but modulated by weakly dependent three-dimensional spatial functions. These functions satisfy parabolic differential equations, with a different diffusion coefficient for each mode. Representative one-speed time-independent transport problems are solved in terms of these generalised Case eigenfunctions. Our treatment is very heuristic, but may provide an impetus for more rigorous analysis. (author)

  10. HPTAM, a two-dimensional Heat Pipe Transient Analysis Model, including the startup from a frozen state

    Science.gov (United States)

    Tournier, Jean-Michel; El-Genk, Mohamed S.

    1995-01-01

    A two-dimensional Heat Pipe Transient Analysis Model, 'HPTAM,' was developed to simulate the transient operation of fully-thawed heat pipes and the startup of heat pipes from a frozen state. The model incorporates: (a) sublimation and resolidification of working fluid; (b) melting and freezing of the working fluid in the porous wick; (c) evaporation of thawed working fluid and condensation as a thin liquid film on a frozen substrate; (d) free-molecule, transition, and continuum vapor flow regimes, using the Dusty Gas Model; (e) liquid flow and heat transfer in the porous wick; and (f) thermal and hydrodynamic couplings of phases at their respective interfaces. HPTAM predicts the radius of curvature of the liquid meniscus at the liquid-vapor interface and the radial location of the working fluid level (liquid or solid) in the wick. It also includes the transverse momentum jump condition (capillary relationship of Pascal) at the liquid-vapor interface and geometrically relates the radius of curvature of the liquid meniscus to the volume fraction of vapor in the wick. The present model predicts the capillary limit and partial liquid recess (dryout) in the evaporator wick, and incorporates a liquid pooling submodel, which simulates accumulation of the excess liquid in the vapor core at the condenser end.

  11. Development of three-dimensional individual bubble-velocity measurement method by bubble tracking

    International Nuclear Information System (INIS)

    Kanai, Taizo; Furuya, Masahiro; Arai, Takahiro; Shirakawa, Kenetsu; Nishi, Yoshihisa

    2012-01-01

    A gas-liquid two-phase flow in a large diameter pipe exhibits a three-dimensional flow structure. Wire-Mesh Sensor (WMS) consists of a pair of parallel wire layers located at the cross section of a pipe. Both the parallel wires cross at 90o with a small gap and each intersection acts as an electrode. The WMS allows the measurement of the instantaneous two-dimensional void-fraction distribution over the cross-section of a pipe, based on the difference between the local instantaneous conductivity of the two-phase flow. Furthermore, the WMS can acquire a phasic-velocity on the basis of the time lag of void signals between two sets of WMS. Previously, the acquired phasic velocity was one-dimensional with time-averaged distributions. The authors propose a method to estimate the three-dimensional bubble-velocity individually WMS data. The bubble velocity is determined by the tracing method. In this tracing method, each bubble is separated from WMS signal, volume and center coordinates of the bubble is acquired. Two bubbles with near volume at two WMS are considered as the same bubble and bubble velocity is estimated from the displacement of the center coordinates of the two bubbles. The validity of this method is verified by a swirl flow. The proposed method can successfully visualize a swirl flow structure and the results of this method agree with the results of cross-correlation analysis. (author)

  12. Three-dimensional echocardiographic assessment of atrial septal defects

    Directory of Open Access Journals (Sweden)

    Charles German

    2015-01-01

    Full Text Available Echocardiography provides a useful tool in the diagnosis of many congenital heart diseases, including atrial septal defects, and aids in further delineating treatment options. Although two-dimensional echocardiography has been the standard of care in this regard, technological advancements have made three-dimensional echocardiography possible, and the images obtained in this new imaging modality are able to accurately portray the morphology, location, dimensions, and dynamic changes of defects and many other heart structures during the cardiac cycle.

  13. New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

    Science.gov (United States)

    Qin, J. J.; Jones, M.; Shiota, T.; Greenberg, N. L.; Firstenberg, M. S.; Tsujino, H.; Zetts, A. D.; Sun, J. P.; Cardon, L. A.; Odabashian, J. A.; hide

    2000-01-01

    AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, Pmethods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

  14. A Monte Carlo Green's function method for three-dimensional neutron transport

    International Nuclear Information System (INIS)

    Gamino, R.G.; Brown, F.B.; Mendelson, M.R.

    1992-01-01

    This paper describes a Monte Carlo transport kernel capability, which has recently been incorporated into the RACER continuous-energy Monte Carlo code. The kernels represent a Green's function method for neutron transport from a fixed-source volume out to a particular volume of interest. This method is very powerful transport technique. Also, since kernels are evaluated numerically by Monte Carlo, the problem geometry can be arbitrarily complex, yet exact. This method is intended for problems where an ex-core neutron response must be determined for a variety of reactor conditions. Two examples are ex-core neutron detector response and vessel critical weld fast flux. The response is expressed in terms of neutron transport kernels weighted by a core fission source distribution. In these types of calculations, the response must be computed for hundreds of source distributions, but the kernels only need to be calculated once. The advance described in this paper is that the kernels are generated with a highly accurate three-dimensional Monte Carlo transport calculation instead of an approximate method such as line-of-sight attenuation theory or a synthesized three-dimensional discrete ordinates solution

  15. Gender differences in knee joint cartilage thickness, volume and articular surface areas: assessment with quantitative three-dimensional MR imaging

    International Nuclear Information System (INIS)

    Faber, S.C.; Reiser, M.; Englmeier, K.H.

    2001-01-01

    Objective: To compare the cartilage thickness, volume, and articular surface areas of the knee joint between young healthy, non-athletic female and male individuals. Subjects and design. MR imaging was performed in 18 healthy subjects without local or systemic joints disease (9 female, age 22.3±2.4 years, and 9 male, age 22.2.±1.9 years), using a fat-suppressed FLASH 3D pulse sequence (TR=41 ms, TE=11 ms, FA=30 ) with sagittal orientation and a spatial resolution of 2x0.31x0.31 mm 3 . After three-dimensional reconstruction and triangulation of the knee joint cartilage plates, the cartilage thickness (mean and maximal), volume, and size of the articular surface area were quantified, independent of the original section orientation. Results and conclusions: Women displayed smaller cartilage volumes than men, the percentage difference ranging from 19.9% in the patella, to 46.6% in the medial tibia. The gender differences of the cartilage thickness were smaller, ranging from 2.0% in the femoral trochlea to 13.3% in the medial tibia for the mean thickness, and from 4.3% in the medial femoral condyle to 18.3% in the medial tibia for the maximal cartilage thickness. The differences between the cartilage surface areas were similar to those of the volumes, with values ranging from 21.0% in the femur to 33.4% in the lateral tibia. Gender differences could be reduced for cartilage volume and surface area when normalized to body weight and body weight x body height. The study demonstrates significant gender differences in cartilage volume and surface area of men and women, which need to be taken into account when retrospectively estimating articular cartilage loss in patients with symptoms of degenerative joint disease. Differences in cartilage volume are primarily due to differences in joint surface areas (epiphyseal bone size), not to differences in cartilage thickness. (orig.)

  16. Global Classical and Weak Solutions to the Three-Dimensional Full Compressible Navier-Stokes System with Vacuum and Large Oscillations

    Science.gov (United States)

    Huang, Xiangdi; Li, Jing

    2018-03-01

    For the three-dimensional full compressible Navier-Stokes system describing the motion of a viscous, compressible, heat-conductive, and Newtonian polytropic fluid, we establish the global existence and uniqueness of classical solutions with smooth initial data which are of small energy but possibly large oscillations where the initial density is allowed to vanish. Moreover, for the initial data, which may be discontinuous and contain vacuum states, we also obtain the global existence of weak solutions. These results generalize previous ones on classical and weak solutions for initial density being strictly away from a vacuum, and are the first for global classical and weak solutions which may have large oscillations and can contain vacuum states.

  17. [Three-dimensional computer aided design for individualized post-and-core restoration].

    Science.gov (United States)

    Gu, Xiao-yu; Wang, Ya-ping; Wang, Yong; Lü, Pei-jun

    2009-10-01

    To develop a method of three-dimensional computer aided design (CAD) of post-and-core restoration. Two plaster casts with extracted natural teeth were used in this study. The extracted teeth were prepared and scanned using tomography method to obtain three-dimensional digitalized models. According to the basic rules of post-and-core design, posts, cores and cavity surfaces of the teeth were designed using the tools for processing point clouds, curves and surfaces on the forward engineering software of Tanglong prosthodontic system. Then three-dimensional figures of the final restorations were corrected according to the configurations of anterior teeth, premolars and molars respectively. Computer aided design of 14 post-and-core restorations were finished, and good fitness between the restoration and the three-dimensional digital models were obtained. Appropriate retention forms and enough spaces for the full crown restorations can be obtained through this method. The CAD of three-dimensional figures of the post-and-core restorations can fulfill clinical requirements. Therefore they can be used in computer-aided manufacture (CAM) of post-and-core restorations.

  18. Assessment of inter-atrial, inter-ventricular, and atrio-ventricular interactions in tetralogy of Fallot patients after surgical correction. Insights from two-dimensional speckle tracking and three-dimensional echocardiography.

    Science.gov (United States)

    Abd El Rahman, Mohamed; Raedle-Hurst, Tanja; Rentzsch, Axel; Schäfers, Hans-Joachim; Abdul-Khaliq, Hashim

    2015-10-01

    We aimed to assess biatrial size and function, interactions on atrial and ventricular levels, and atrio-ventricular coupling in patients after tetralogy of Fallot repair. A total of 34 patients with a mean age of 20.9±9 years, and 35 healthy controls, underwent two-dimensional speckle tracking echocardiography for ventricular and atrial strain measurements and real-time three-dimensional echocardiography to assess ventricular and atrial volumes. When compared with controls, tetralogy of Fallot patients had significantly reduced right atrial peak atrial longitudinal strain (ptetralogy of Fallot group, left ventricular ejection fraction was negatively related to the right ventricular end-systolic volume normalised to body surface area (r=-0.62, ptetralogy of Fallot patients, biatrial dysfunction exists and can be quantified via two-dimensional speckle tracking echocardiography as well as real-time three-dimensional echocardiography. Different forms of interactions on atrial and ventricular levels are evident among such cohorts.

  19. Integrated microchannel cooling in a three dimensional integrated circuit: A thermal management

    Directory of Open Access Journals (Sweden)

    Wang Kang-Jia

    2016-01-01

    Full Text Available Microchannel cooling is a promising technology for solving the three-dimensional integrated circuit thermal problems. However, the relationship between the microchannel cooling parameters and thermal behavior of the three dimensional integrated circuit is complex and difficult to understand. In this paper, we perform a detailed evaluation of the influence of the microchannel structure and the parameters of the cooling liquid on steady-state temperature profiles. The results presented in this paper are expected to aid in the development of thermal design guidelines for three dimensional integrated circuit with microchannel cooling.

  20. Three-Dimensional Non-Coplanar Conformal Radiotherapy Yields Better Results Than Traditional Beam Arrangements for Adjuvant Treatment of Gastric Cancer

    International Nuclear Information System (INIS)

    Soyfer, Viacheslav; Corn, Benjamin W.; Melamud, Alex B.S.; Alani, Shlomi; Tempelhof, Haim; Agai, Reuben; Shmueli, Anat; Figer, Arie; Kovner, Felix

    2007-01-01

    Purpose: The current standard of adjuvant treatment for gastric cancer after curative resection is concurrent administration of radiotherapy and 5-fluorouracil-based chemotherapy. The radiation fields are often arranged as anterioposterior-posteroanterior opposed parallel fields with general recommendations for sparing at least two-thirds of one kidney. We investigated whether a better radiation distribution would be achievable with three-dimensional conformal approaches compared with the classic anterioposterior-posteroanterior fields. Methods and Materials: A total of 19 patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a non-coplanar four-field arrangement. In each case, parallel planning using an anterioposterior-posteroanterior arrangement and a four-field 'box' was performed, and the generated plans were subsequently compared for coverage of target volumes and doses to irradiated organs next to the tumor bed. A separate analysis was performed for kidneys exposed to greater and lower doses in each patient. The mean radiation dose and percentage of kidney volume receiving a dose >20 Gy were registered. Statistical analysis was performed using the two-tailed t test. Results: The clinical target volume was adequately covered in all three plans. In the greater-dose kidney group, all the differences were statistically significant with a benefit for the three-dimensional plan. In the lower-dose kidney group, the differences in the mean radiation dose did not reach the level of statistical significance, and the differences in the kidney volume receiving a dose >20 Gy showed a statistically significant benefit for the three-dimensional plan. Conclusion: Non-coplanar three-dimensional-based conformal planning for postoperative radiotherapy for gastric cancer provided the best results regarding kidney and spinal cord exposure with adequate clinical target volume coverage. This technique was readily implemented in clinical

  1. Three-dimensional non-coplanar conformal radiotherapy yields better results than traditional beam arrangements for adjuvant treatment of gastric cancer.

    Science.gov (United States)

    Soyfer, Viacheslav; Corn, Benjamin W; Melamud, Alex; Alani, Shlomi; Tempelhof, Haim; Agai, Reuben; Shmueli, Anat; Figer, Arie; Kovner, Felix

    2007-10-01

    The current standard of adjuvant treatment for gastric cancer after curative resection is concurrent administration of radiotherapy and 5-fluorouracil-based chemotherapy. The radiation fields are often arranged as anterioposterior-posteroanterior opposed parallel fields with general recommendations for sparing at least two-thirds of one kidney. We investigated whether a better radiation distribution would be achievable with three-dimensional conformal approaches compared with the classic anterioposterior-posteroanterior fields. A total of 19 patients with adenocarcinoma of the stomach were treated with adjuvant chemoradiotherapy using a non-coplanar four-field arrangement. In each case, parallel planning using an anterioposterior-posteroanterior arrangement and a four-field "box" was performed, and the generated plans were subsequently compared for coverage of target volumes and doses to irradiated organs next to the tumor bed. A separate analysis was performed for kidneys exposed to greater and lower doses in each patient. The mean radiation dose and percentage of kidney volume receiving a dose >20 Gy were registered. Statistical analysis was performed using the two-tailed t test. The clinical target volume was adequately covered in all three plans. In the greater-dose kidney group, all the differences were statistically significant with a benefit for the three-dimensional plan. In the lower-dose kidney group, the differences in the mean radiation dose did not reach the level of statistical significance, and the differences in the kidney volume receiving a dose >20 Gy showed a statistically significant benefit for the three-dimensional plan. Non-coplanar three-dimensional-based conformal planning for postoperative radiotherapy for gastric cancer provided the best results regarding kidney and spinal cord exposure with adequate clinical target volume coverage. This technique was readily implemented in clinical practice.

  2. Tumor Volume Changes Assessed by Three-Dimensional Magnetic Resonance Volumetry in Rectal Cancer Patients After Preoperative Chemoradiation: The Impact of the Volume Reduction Ratio on the Prediction of Pathologic Complete Response

    International Nuclear Information System (INIS)

    Kang, Jeong Hyun; Kim, Young Chul; Kim, Hyunki; Kim, Young Wan; Hur, Hyuk; Kim, Jin Soo; Min, Byung Soh; Kim, Hogeun; Lim, Joon Seok; Seong, Jinsil; Keum, Ki Chang; Kim, Nam Kyu

    2010-01-01

    Purpose: The aim of this study was to determine the correlation between tumor volume changes assessed by three-dimensional (3D) magnetic resonance (MR) volumetry and the histopathologic tumor response in rectal cancer patients undergoing preoperative chemoradiation therapy (CRT). Methods and Materials: A total of 84 patients who underwent preoperative CRT followed by radical surgery were prospectively enrolled in the study. The post-treatment tumor volume and tumor volume reduction ratio (% decrease ratio), as shown by 3D MR volumetry, were compared with the histopathologic response, as shown by T and N downstaging and the tumor regression grade (TRG). Results: There were no significant differences in the post-treatment tumor volume and the volume reduction ratio shown by 3D MR volumetry with respect to T and N downstaging and the tumor regression grade. In a multivariate analysis, the tumor volume reduction ratio was not significantly associated with T and N downstaging. The volume reduction ratio (>75%, p = 0.01) and the pretreatment carcinoembryonic antigen level (≤3 ng/ml, p = 0.01), but not the post-treatment volume shown by 3D MR (≤ 5ml), were, however, significantly associated with an increased pathologic complete response rate. Conclusion: More than 75% of the tumor volume reduction ratios were significantly associated with a high pathologic complete response rate. Therefore, limited treatment options such as local excision or simple observation might be considered after preoperative CRT in this patient population.

  3. How does knowledge of three-dimensional excision margins following breast conservation surgery impact upon clinical target volume definition for partial-breast radiotherapy?

    International Nuclear Information System (INIS)

    Kirby, Anna M.; Evans, Philip M.; Nerurkar, Ashutosh Y.; Desai, Saral S.; Krupa, Jaroslaw; Devalia, Haresh; Rovere, Guidubaldo Querci della; Harris, Emma J.; Kyriakidou, Julia; Yarnold, John R.

    2010-01-01

    Background and purpose: To compare partial-breast clinical target volumes generated using a standard 15 mm margin (CTV standard ) with those generated using three-dimensional surgical excision margins (CTV tailored30 ) in women who have undergone wide local excision (WLE) for breast cancer. Material and methods: Thirty-five women underwent WLE with placement of clips in the anterior, deep and coronal excision cavity walls. Distances from tumour to each of six margins were measured microscopically. Tumour bed was defined on kV-CT images using clips. CTV standard was generated by adding a uniform three-dimensional 15 mm margin, and CTV tailored30 was generated by adding 30 mm minus the excision margin in three-dimensions. Concordance between CTV standard and CTV tailored30 was quantified using conformity (CoI), geographical-miss (GMI) and normal-tissue (NTI) indices. An external-beam partial-breast irradiation (PBI) plan was generated to cover 95% of CTV standard with the 95% isodose. Percentage-volume coverage of CTV tailored30 by the 95% isodose was measured. Results: Median (range) coronal, superficial and deep excision margins were 15.0 (0.5-76.0) mm, 4.0 (0.0-60.0) mm and 4.0 (0.5-35.0) mm, respectively. Median CoI, GMI and NTI were 0.62, 0.16 and 0.20, respectively. Median coverage of CTV tailored30 by the PBI-plan was 97.7% (range 84.9-100.0%). CTV tailored30 was inadequately covered by the 95% isodose in 4/29 cases. In three cases, the excision margin in the direction of inadequate coverage was ≤2 mm. Conclusions: CTVs based on 3D excision margin data are discordant with those defined using a standard uniform 15 mm TB-CTV margin. In women with narrow excision margins, the standard TB-CTV margin could result in a geographical miss. Therefore, wider TB-CTV margins should be considered where re-excision does not occur.

  4. The effect of deformation twinning on stress localization in a three dimensional TWIP steel microstructure

    International Nuclear Information System (INIS)

    Tari, Vahid; Kadiri, Haitham El; Oppedal, Andrew L; King, Roger L; Rollett, Anthony D; Beladi, Hossein

    2015-01-01

    We present an investigation of the effect of deformation twinning on the visco-plastic response and stress localization in a low stacking fault energy twinning-induced plasticity (TWIP) steel under uniaxial tension loading. The three-dimensional full field response was simulated using the fast Fourier transform method. The initial microstructure was obtained from a three dimensional serial section using electron backscatter diffraction. Twin volume fraction evolution upon strain was measured so the hardening parameters of the simple Voce model could be identified to fit both the stress-strain behavior and twinning activity. General trends of texture evolution were acceptably predicted including the typical sharpening and balance between the 〈1 1 1〉 fiber and the 〈1 0 0〉 fiber. Twinning was found to nucleate preferentially at grain boundaries although the predominant twin reorientation scheme did not allow spatial propagation to be captured. Hot spots in stress correlated with the boundaries of twinned voxel domains, which either impeded or enhanced twinning based on which deformation modes were active locally. (paper)

  5. Clinical applications for multiplanar- and three-dimensional-reconstructions by helical-CT for the diagnosis of acetabular fractures

    International Nuclear Information System (INIS)

    Stroszczynski, C.; Schedel, H.; Stoeckle, U.; Wellmann, A.; Beier, J.; Wicht, L.; Hoffmann, R.; Felix, R.

    1996-01-01

    This review describes recent visualizations of computed tomography for the diagnosis of acetabular fractures. The techniques of conventional and helical-CT for the imaging of the acetabulum are compared. Furthermore, the different methods of multiplaner and three-dimensional reconstructions e.g. shaded surface display, maximum intensity projection, and volume rendering are presented. Figures of multiplanar and three-dimensional imaging for fractures of the pelvis is discussed. (orig.) [de

  6. The role of three dimensional functional lung imaging in radiation treatment planning: the functional dose-volume histogram

    International Nuclear Information System (INIS)

    Marks, Lawrence B.; Spencer, David P.; Sherouse, George W.; Bentel, Gunilla; Clough, Robert; Vann, Karen; Jaszczak, Ronald; Coleman, R. Edward; Prosnitz, Leonard R.

    1995-01-01

    Purpose: During thoracic irradiation (XRT), treatment fields are usually designed to minimize the volume of nontumor-containing lung included. Generally, functional heterogeneities within the lung are not considered. The three dimensional (3D) functional information provided by single photon emission computed tomography (SPECT) lung perfusion scans might be useful in designing beams that minimize incidental irradiation of functioning lung tissue. We herein review the pretreatment SPECT scans in 86 patients (56 with lung cancer) to determine which are likely to benefit from this technology. Methods and Materials: Prior to thoracic XRT, SPECT lung perfusion scans were obtained following the intravenous injection of ∼4 mCi of 99m Tc-labeled macro-aggregated albumin. The presence of areas of decreased perfusion, their location relative to the tumor, and the potential clinical usefulness of their recognition, were scored. Patients were grouped and compared (two-tailed chi-square) based on clinical factors. Conventional dose-volume histograms (DVHs) and functional DVHs (DV F Hs) are calculated based on the dose distribution throughout the computed tomography (CT)-defined lung and SPECT-defined perfused lung, respectively. Results: Among 56 lung cancer patients, decreases in perfusion were observed at the tumor, adjacent to the tumor, and separate from the tumor in 94%, 74%, and 42% of patients, respectively. Perfusion defects adjacent to the tumor were often large with centrally placed tumors. Hypoperfusion in regions separate from the tumor were statistically most common in patients with relatively poor pulmonary function and chronic obstructive pulmonary disease (COPD). Considering all SPECT defects adjacent to and separate from the tumor, corresponding CT abnormalities were seen in only ∼50% and 20% of patients, respectively, and were generally not as impressive. Following XRT, hypoperfusion at and separate from the tumor persisted, while defects adjacent to the

  7. World-volume effective theory for higher-dimensional black holes.

    Science.gov (United States)

    Emparan, Roberto; Harmark, Troels; Niarchos, Vasilis; Obers, Niels A

    2009-05-15

    We argue that the main feature behind novel properties of higher-dimensional black holes, compared to four-dimensional ones, is that their horizons can have two characteristic lengths of very different size. We develop a long-distance world-volume effective theory that captures the black hole dynamics at scales much larger than the short scale. In this limit the black hole is regarded as a blackfold: a black brane (possibly boosted locally) whose world volume spans a curved submanifold of the spacetime. This approach reveals black objects with novel horizon geometries and topologies more complex than the black ring, but more generally it provides a new organizing framework for the dynamics of higher-dimensional black holes.

  8. Three-dimensional characterization of pores in Ti-6Al-4V alloy

    Directory of Open Access Journals (Sweden)

    Márcia Regina Baldissera

    2011-03-01

    Full Text Available The direct three-dimensional characterization of opaque materials through serial sectioning makes possible to visualize and better quantify a material microstructure, using classical metallographic techniques coupled with computer-aided reconstruction. Titanium alloys are used as biomaterials for bone implants because of its excellent mechanical properties, biocompatibility and enhanced corrosion resistance. The Ti-6Al-4V alloy (in wt. (% with porous microstructure permits the ingrowths of new-bone tissues improving the fixation bone/implant. This is important to understand connectivity, morphology and spatial distribution of pores in microstructure. The Ti-6Al-4V alloy compacts were produced by powder metallurgy and sintered at three distinct temperatures (1250, 1400 and 1500 °C to obtain distinct microstructures in terms of residual porosity. The visualization of the reconstructed 3D microstructure provides a qualitative and quantitative analysis of the porosity of Ti6Al4V alloy (volume fraction and pore morphology.

  9. Creation of three-dimensional craniofacial standards from CBCT images

    Science.gov (United States)

    Subramanyan, Krishna; Palomo, Martin; Hans, Mark

    2006-03-01

    Low-dose three-dimensional Cone Beam Computed Tomography (CBCT) is becoming increasingly popular in the clinical practice of dental medicine. Two-dimensional Bolton Standards of dentofacial development are routinely used to identify deviations from normal craniofacial anatomy. With the advent of CBCT three dimensional imaging, we propose a set of methods to extend these 2D Bolton Standards to anatomically correct surface based 3D standards to allow analysis of morphometric changes seen in craniofacial complex. To create 3D surface standards, we have implemented series of steps. 1) Converting bi-plane 2D tracings into set of splines 2) Converting the 2D splines curves from bi-plane projection into 3D space curves 3) Creating labeled template of facial and skeletal shapes and 4) Creating 3D average surface Bolton standards. We have used datasets from patients scanned with Hitachi MercuRay CBCT scanner providing high resolution and isotropic CT volume images, digitized Bolton Standards from age 3 to 18 years of lateral and frontal male, female and average tracings and converted them into facial and skeletal 3D space curves. This new 3D standard will help in assessing shape variations due to aging in young population and provide reference to correct facial anomalies in dental medicine.

  10. A three-dimensional magnetostatics computer code for insertion devices

    International Nuclear Information System (INIS)

    Chubar, O.; Elleaume, P.; Chavanne, J.

    1998-01-01

    RADIA is a three-dimensional magnetostatics computer code optimized for the design of undulators and wigglers. It solves boundary magnetostatics problems with magnetized and current-carrying volumes using the boundary integral approach. The magnetized volumes can be arbitrary polyhedrons with non-linear (iron) or linear anisotropic (permanent magnet) characteristics. The current-carrying elements can be straight or curved blocks with rectangular cross sections. Boundary conditions are simulated by the technique of mirroring. Analytical formulae used for the computation of the field produced by a magnetized volume of a polyhedron shape are detailed. The RADIA code is written in object-oriented C++ and interfaced to Mathematica (Mathematica is a registered trademark of Wolfram Research, Inc.). The code outperforms currently available finite-element packages with respect to the CPU time of the solver and accuracy of the field integral estimations. An application of the code to the case of a wedge-pole undulator is presented

  11. Fusion of three-dimensional X-ray angiography and three-dimensional echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Rasche, Volker [University of Ulm, Department of Internal Medicine II, Ulm (Germany); Philips Medical Systems, Bothell, WA (United States); Mansour, Moussa; Reddy, Vivek; Singh, Jagmeet P.; Ruskin, Jeremy [Massachusetts General Hospital, Harvard Medical School, Cardiac Arrhythmia Service, Boston, MA (United States); Qureshi, Answer [Massachusetts General Hospital, Harvard Medical School, Echocardiography, Boston, MA (United States); Manzke, Robert; Sokka, Sham [Philips Research North America, Clinical Sites Research, Briacliff Manor, NY (United States)

    2008-03-15

    Cardiovascular intervention guidance requires knowledge of heart function relative to its blood supply or venous drainage. Functional and vascular anatomic data are usually generated on different imaging systems, so fusion of the data is necessary to simultaneously visualize the results for intervention planning and guidance. The objective of this work is to establish the feasibility of fusing volumetric ultrasound (U/S) data with three-dimensional (3D) X-ray imaging data for visualization of cardiac morphology, function and coronary venous drainage. Temporally resolved U/S volume data was registered with the 3D reconstruction of vascular structures derived from X-ray modeling and reconstruction. U/S image registration was obtained by optical tracking fiducial markers with simultaneous X-ray imaging. The proposed technique was applied to phantom data for accuracy assessment of the registration process and to biventricular pacemaker implantation as clinical example. Fusion of U/S data with 3D X-ray reconstruction data produced an RMS registration error below 2 mm. Preliminary clinical feasibility of U/S-derived data synchronously with X-ray derived 3D coronary venography was established. This technique can be applied for fusion of functional U/S data with 3D anatomic X-ray data of the coronary veins during a biventricular pacemaker implantation procedures. (orig.)

  12. Fusion of three-dimensional X-ray angiography and three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Rasche, Volker; Mansour, Moussa; Reddy, Vivek; Singh, Jagmeet P.; Ruskin, Jeremy; Qureshi, Answer; Manzke, Robert; Sokka, Sham

    2008-01-01

    Cardiovascular intervention guidance requires knowledge of heart function relative to its blood supply or venous drainage. Functional and vascular anatomic data are usually generated on different imaging systems, so fusion of the data is necessary to simultaneously visualize the results for intervention planning and guidance. The objective of this work is to establish the feasibility of fusing volumetric ultrasound (U/S) data with three-dimensional (3D) X-ray imaging data for visualization of cardiac morphology, function and coronary venous drainage. Temporally resolved U/S volume data was registered with the 3D reconstruction of vascular structures derived from X-ray modeling and reconstruction. U/S image registration was obtained by optical tracking fiducial markers with simultaneous X-ray imaging. The proposed technique was applied to phantom data for accuracy assessment of the registration process and to biventricular pacemaker implantation as clinical example. Fusion of U/S data with 3D X-ray reconstruction data produced an RMS registration error below 2 mm. Preliminary clinical feasibility of U/S-derived data synchronously with X-ray derived 3D coronary venography was established. This technique can be applied for fusion of functional U/S data with 3D anatomic X-ray data of the coronary veins during a biventricular pacemaker implantation procedures. (orig.)

  13. Validation of a Full-Immersion Simulation Platform for Percutaneous Nephrolithotomy Using Three-Dimensional Printing Technology.

    Science.gov (United States)

    Ghazi, Ahmed; Campbell, Timothy; Melnyk, Rachel; Feng, Changyong; Andrusco, Alex; Stone, Jonathan; Erturk, Erdal

    2017-12-01

    The restriction of resident hours with an increasing focus on patient safety and a reduced caseload has impacted surgical training. A complex and complication prone procedure such as percutaneous nephrolithotomy (PCNL) with a steep learning curve may create an unsafe environment for hands-on resident training. In this study, we validate a high fidelity, inanimate PCNL model within a full-immersion simulation environment. Anatomically correct models of the human pelvicaliceal system, kidney, and relevant adjacent structures were created using polyvinyl alcohol hydrogels and three-dimensional-printed injection molds. All steps of a PCNL were simulated including percutaneous renal access, nephroscopy, and lithotripsy. Five experts (>100 caseload) and 10 novices (simulation. Face and content validity were calculated using model ratings for similarity to the real procedure and usefulness as a training tool. Differences in performance among groups with various levels of experience using clinically relevant procedural metrics were used to calculate construct validity. The model was determined to have an excellent face and content validity with an average score of 4.5/5.0 and 4.6/5.0, respectively. There were significant differences between novice and expert operative metrics including mean fluoroscopy time, the number of percutaneous access attempts, and number of times the needle was repositioned. Experts achieved better stone clearance with fewer procedural complications. We demonstrated the face, content, and construct validity of an inanimate, full task trainer for PCNL. Construct validity between experts and novices was demonstrated using incorporated procedural metrics, which permitted the accurate assessment of performance. While hands-on training under supervision remains an integral part of any residency, this full-immersion simulation provides a comprehensive tool for surgical skills development and evaluation before hands-on exposure.

  14. Three-dimensional effects on cracked components under anti-plane loading

    Directory of Open Access Journals (Sweden)

    F. Berto

    2015-07-01

    Full Text Available The existence of three-dimensional effects at cracks has been known for many years, but understanding has been limited, and for some situations still is. Understanding improved when the existence of corner point singularities and their implications became known. Increasingly powerful computers made it possible to investigate three-dimensional effects numerically in detail. Despite increased understanding, threedimensional effects are sometimes ignored in situations where they may be important. The purpose of the present investigation is to study by means of accurate 3D finite element (FE models a coupled fracture mode generated by anti-plane loading of a straight through-the-thickness crack in linear elastic plates. An extended version of the present work has recently been published in the literature. The results obtained from the highly accurate finite element analyses have improved understanding of the behaviour of through cracked components under anti-plane loading. The influence of plate bending is increasingly important as the thickness decreases. It appears that a new field parameter, probably a singularity, is needed to describe the stresses at the free surfaces. Discussion on whether KIII tends to zero or infinity as a corner point is approached is futile because KIII is meaningless at a corner point. The intensity of the local stress and strain state through the thickness of the cracked components has been evaluated by using the strain energy density (SED averaged over a control volume embracing the crack tip. The SED has been considered as a parameter able to control fracture in some previous contributions and can easily take into account also coupled three-dimensional effects. Calculation of the SED shows that the position of the maximum SED is independent of plate thickness. Both for thin plates and for thick ones the maximum SED is close to the lateral surface, where the maximum intensity of the coupled mode II takes place.

  15. A correlation study on position and volume variation of primary lung cancer during respiration by four-dimensional CT

    International Nuclear Information System (INIS)

    Zhang Yingjie; Li Jianbin; Tian Shiyu; Li Fengxiang; Fan Tingyong; Shao Qian; Xu Min; Lu Jie

    2011-01-01

    Objective: To investigate the correlation of position movement of primary tumor with interested organs and skin markers, and to investigate the correlation of volume variation of primary tumors and lungs during different respiration phases for patients with lung cancer at free breath condition scanned by four-dimensional CT (4DCT) simulation. Methods: 16 patients with lung cancer were scanned at free breath condition by simulation 4DCT which connected to a respiration-monitoring system. A coordinate system was created based on image of T 5 phase,gross tumor volume (GTV) and normal tissue structures of 10 phases were contoured. The three dimensional position variation of them were measured and their correlation were analyzed, and the same for the volume variation of GTV and lungs of 10 respiratory phases. Results: Movement range of lung cancer in different lobe differed extinct: 0.8 - 5.0 mm in upper lobe, 5.7 -5.9 mm in middle lobe and 10.2 - 13.7 mm in lower lobe, respectively. Movement range of lung cancer in three dimensional direction was different: z-axis 4.3 mm ± 4.3 mm > y-axis 2.2 mm ± 1.0 mm > x-axis 1.7 mm ± 1.5 mm (χ 2 =16.22, P =0.000), respectively. There was no statistical significant correlation for movement vector of GTV and interested structures (r =-0.50 - -0.01, P =0.058 - -0.961), nor for volume variation of tumor and lung (r =0.23, P =0.520). Conclusions: Based on 4DCT, statistically significant differences of GTV centroid movement are observed at different pulmonary lobes and in three dimensional directions. So individual 4DCT measurement is necessary for definition of internal target volume margin for lung cancer. (authors)

  16. Three dimensional characterization of laser ablation craters using high resolution X-ray computed tomography

    Science.gov (United States)

    Galmed, A. H.; du Plessis, A.; le Roux, S. G.; Hartnick, E.; Von Bergmann, H.; Maaza, M.

    2018-01-01

    Laboratory X-ray computed tomography is an emerging technology for the 3D characterization and dimensional analysis of many types of materials. In this work we demonstrate the usefulness of this characterization method for the full three dimensional analysis of laser ablation craters, in the context of a laser induced breakdown spectroscopy setup. Laser induced breakdown spectroscopy relies on laser ablation for sampling the material of interest. We demonstrate here qualitatively (in images) and quantitatively (in terms of crater cone angles, depths, diameters and volume) laser ablation crater analysis in 3D for metal (aluminum) and rock (false gold ore). We show the effect of a Gaussian beam profile on the resulting crater geometry, as well as the first visual evidence of undercutting in the rock sample, most likely due to ejection of relatively large grains. The method holds promise for optimization of laser ablation setups especially for laser induced breakdown spectroscopy.

  17. MRI of the lateral ankle ligaments: value of three-dimensional orientation

    International Nuclear Information System (INIS)

    Mayerhoefer, M.E.; Breitenseher, M.J.

    2003-01-01

    Purpose: To determine the three-dimensional orientation of the lateral ankle ligaments with MRI. Materials and Methods: Twenty healthy volunteers without previous injury to the ankle were included in the study. With the right ankle in the normal anatomic position stabilized in a splint, coronal T2-weighted spin-echo sequences (TSE) were obtained. The three-dimensional orientation was determined by placing paths through the ligaments and by measuring the angles between corresponding tangents and the three main imaging planes. Results: Using the calculated angles, full-length visualization of the lateral ligaments of the ankle was achieved. The angles deviating from the axial imaging plane were 18.0 degrees for the anterior talofibular ligament, 52.3 degrees for the calcaneofibular ligament and 28.2 degrees for the posterior talofibular ligament. Conclusion: MRI enables the exact determination of the three-dimensional orientation of the lateral ankle ligaments. Orienting the imaging planes according to the calculated angular deviation allows the full-length visualization of the ligaments and is the basis for optimal imaging of the lateral ankle ligaments. (orig.) [de

  18. CVD-MPFA full pressure support, coupled unstructured discrete fracture-matrix Darcy-flux approximations

    Science.gov (United States)

    Ahmed, Raheel; Edwards, Michael G.; Lamine, Sadok; Huisman, Bastiaan A. H.; Pal, Mayur

    2017-11-01

    Two novel control-volume methods are presented for flow in fractured media, and involve coupling the control-volume distributed multi-point flux approximation (CVD-MPFA) constructed with full pressure support (FPS), to two types of discrete fracture-matrix approximation for simulation on unstructured grids; (i) involving hybrid grids and (ii) a lower dimensional fracture model. Flow is governed by Darcy's law together with mass conservation both in the matrix and the fractures, where large discontinuities in permeability tensors can occur. Finite-volume FPS schemes are more robust than the earlier CVD-MPFA triangular pressure support (TPS) schemes for problems involving highly anisotropic homogeneous and heterogeneous full-tensor permeability fields. We use a cell-centred hybrid-grid method, where fractures are modelled by lower-dimensional interfaces between matrix cells in the physical mesh but expanded to equi-dimensional cells in the computational domain. We present a simple procedure to form a consistent hybrid-grid locally for a dual-cell. We also propose a novel hybrid-grid for intersecting fractures, for the FPS method, which reduces the condition number of the global linear system and leads to larger time steps for tracer transport. The transport equation for tracer flow is coupled with the pressure equation and provides flow parameter assessment of the fracture models. Transport results obtained via TPS and FPS hybrid-grid formulations are compared with the corresponding results of fine-scale explicit equi-dimensional formulations. The results show that the hybrid-grid FPS method applies to general full-tensor fields and provides improved robust approximations compared to the hybrid-grid TPS method for fractured domains, for both weakly anisotropic permeability fields and very strong anisotropic full-tensor permeability fields where the TPS scheme exhibits spurious oscillations. The hybrid-grid FPS formulation is extended to compressible flow and the

  19. Transient cavitation in pipelines

    NARCIS (Netherlands)

    Kranenburg, C.

    1974-01-01

    The aim of the present study is to set up a one-dimensional mathematical model, which describes the transient flow in pipelines, taking into account the influence of cavitation and free gas. The flow will be conceived of as a three-phase flow of the liquid, its vapour and non-condensible gas. The

  20. Three-dimensional display by computer graphics method of hepatocellular carcinoma using seen with the hepatic arteriogram

    International Nuclear Information System (INIS)

    Itsubo, Mariko; Kameda, Haruo; Suzuki, Naoki; Okamura, Tetsuo

    1989-01-01

    The method of three-dimensional display of hepatocellular carcinoma using conventional hepatic arteriogram by computer graphics method was newly exploited and applied in clinical use. Three-dimensional models were reconstructed from contour lines of tumors demonstrated as hypervascular lesions by hepatic arteriography. Although objects were limited by angiographic images in which tumors need to be demonstrated as nodules with hypervascularity, this method of three-dimensional display was not worse on accuracy than that using computed tomographic images. According to this method property of the tumor expressed by vascularity was demonstrated clear and in addition volume of the tumor was calculated easily. When the tumor arose in necrotic changes in which demonstrated as a vascular lesion by hepatic arteriography with reduction of size in usual by conservative treatment such as transcathter arterial embolization therapy, this three-dimensional display was able to demonstrate such changes clear. This preliminary study demonstrates the feasibility and clinical usefulness of three-dimensional display of hepatocellular carcinoma using hepatic arteriogram by computer graphics method. (author)

  1. Three-dimensional simulation of vortex breakdown

    Science.gov (United States)

    Kuruvila, G.; Salas, M. D.

    1990-01-01

    The integral form of the complete, unsteady, compressible, three-dimensional Navier-Stokes equations in the conservation form, cast in generalized coordinate system, are solved, numerically, to simulate the vortex breakdown phenomenon. The inviscid fluxes are discretized using Roe's upwind-biased flux-difference splitting scheme and the viscous fluxes are discretized using central differencing. Time integration is performed using a backward Euler ADI (alternating direction implicit) scheme. A full approximation multigrid is used to accelerate the convergence to steady state.

  2. The Topology Optimization of Three-dimensional Cooling Fins by the Internal Element Connectivity Parameterization Method

    International Nuclear Information System (INIS)

    Yoo, Sung Min; Kim, Yoon Young

    2007-01-01

    This work is concerned with the topology optimization of three-dimensional cooling fins or heat sinks. Motivated by earlier success of the Internal Element Connectivity Method (I-ECP) method in two dimensional problems, the extension of I-ECP to three-dimensional problems is carried out. The main efforts were made to maintain the numerical trouble-free characteristics of I-ECP for full three-dimensional problems; a serious numerical problem appearing in thermal topology optimization is erroneous temperature undershooting. The effectiveness of the present implementation was checked through the design optimization of three-dimensional fins

  3. Application of data mining in three-dimensional space time reactor model

    International Nuclear Information System (INIS)

    Jiang Botao; Zhao Fuyu

    2011-01-01

    A high-fidelity three-dimensional space time nodal method has been developed to simulate the dynamics of the reactor core for real time simulation. This three-dimensional reactor core mathematical model can be composed of six sub-models, neutron kinetics model, cay heat model, fuel conduction model, thermal hydraulics model, lower plenum model, and core flow distribution model. During simulation of each sub-model some operation data will be produced and lots of valuable, important information reflecting the reactor core operation status could be hidden in, so how to discovery these information becomes the primary mission people concern. Under this background, data mining (DM) is just created and developed to solve this problem, no matter what engineering aspects or business fields. Generally speaking, data mining is a process of finding some useful and interested information from huge data pool. Support Vector Machine (SVM) is a new technique of data mining appeared in recent years, and SVR is a transformed method of SVM which is applied in regression cases. This paper presents only two significant sub-models of three-dimensional reactor core mathematical model, the nodal space time neutron kinetics model and the thermal hydraulics model, based on which the neutron flux and enthalpy distributions of the core are obtained by solving the three-dimensional nodal space time kinetics equations and energy equations for both single and two-phase flows respectively. Moreover, it describes that the three-dimensional reactor core model can also be used to calculate and determine the reactivity effects of the moderator temperature, boron concentration, fuel temperature, coolant void, xenon worth, samarium worth, control element positions (CEAs) and core burnup status. Besides these, the main mathematic theory of SVR is introduced briefly next, on the basis of which SVR is applied to dealing with the data generated by two sample calculation, rod ejection transient and axial

  4. Three-dimensional investigation of the two-phase flow structure in a bubbly pipe flow

    International Nuclear Information System (INIS)

    Hassan, Y.A.; Schmidl, W.D.; Ortiz-Villafuerte, J.

    1997-01-01

    Particle Image Velocimetry (PIV) is a non-intrusive measurement technique, which can be used to study the structure of various fluid flows. PIV is used to measure the time varying full field velocity data of a particle-seeded flow field within either a two-dimensional plane or three-dimensional volume. PIV is a very efficient measurement technique since it can obtain both qualitative and quantitative spatial information about the flow field being studied. This information can be further processed into information such as vorticity and pathlines. Other flow measurement techniques (Laser Doppler Velocimetry, Hot Wire Anemometry, etc...) only provide quantitative information at a single point. PIV can be used to study turbulence structures if a sufficient amount of data can be acquired and analyzed, and it can also be extended to study two-phase flows if both phases can be distinguished. In this study, the flow structure around a bubble rising in a pipe filled with water was studied in three-dimensions. The velocity of the rising bubble and the velocity field of the surrounding water was measured. Then the turbulence intensities and Reynolds stresses were calculated from the experimental data. (author)

  5. Three-dimensional cross-linking composite of graphene, carbon nanotubes and Si nanoparticles for lithium ion battery anode

    Science.gov (United States)

    Tian, Suyun; Zhu, Guannan; Tang, Yanping; Xie, Xiaohua; Wang, Qian; Ma, Yufei; Ding, Guqiao; Xie, Xiaoming

    2018-03-01

    Various graphene-based Si nanocomposites have been reported to improve the performance of active materials in Li-ion batteries. However, these candidates still yield severe capacity fading due to the electrical disconnection and fractures caused by the huge volume changes over extended cycles. Therefore, we have designed a novel three-dimensional cross-linked graphene and single-wall carbon nanotube structure to encapsulate the Si nanoparticles. The synthesized three-dimensional structure is attributed to the excellent self-assembly of carbon nanotubes with graphene oxide as well as a thermal treatment process at 900 °C. This special structure provides sufficient void spaces for the volume expansion of Si nanoparticles and channels for the diffusion of ions and electrons. In addition, the cross-linking of the graphene and single-wall carbon nanotubes also strengthens the stability of the structure. As a result, the volume expansion of the Si nanoparticles is restrained. The specific capacity remains at 1450 mAh g-1 after 100 cycles at 200 mA g-1. This well-defined three-dimensional structure facilitates superior capacity and cycling stability in comparison with bare Si and a mechanically mixed composite electrode of graphene, single-wall carbon nanotubes and silicon nanoparticles.

  6. Processing and display of medical three dimensional arrays of numerical data using octree encoding

    International Nuclear Information System (INIS)

    Amans, J.L.; Darier, P.

    1985-01-01

    Imaging modalities such as X-ray computerized Tomography (CT), Nuclear Medicine and Nuclear Magnetic Resonance can produce three-dimensional (3-D) arrays of numerical data of medical object internal structures. The analysis of 3-D data by synthetic generation of realistic images is an important area of computer graphics and imaging. We are currently developing experimental software that allows the analysis, processing and display of 3-D arrays of numerical data that are organized in a related hierarchical data structure using OCTREE (octal-tree) encoding technique based on a recursive subdivision of the data volume. The OCTREE encoding structure is an extension of the two-dimensional tree structure: the quadtree, developed for image processing applications. Before any operations, the 3-D array of data is OCTREE encoded, thereafter all processings are concerned with the encoded object. The elementary process for the elaboration of a synthetic image includes: conditioning the volume: volume partition (numerical and spatial segmentation), choice of the view-point..., two dimensional display, either by spatial integration (radiography) or by shaded surface representation. This paper introduces these different concepts and specifies the advantages of OCTREE encoding techniques in realizing these operations. Furthermore the application of the OCTREE encoding scheme to the display of 3-D medical volumes generated from multiple CT scans is presented

  7. Measurements of the frontal and prefrontal lobe volumes by three dimensional magnetic resonance imaging scan. III. Analysis of sex differences with advanced age

    Energy Technology Data Exchange (ETDEWEB)

    Kanemura, Hideaki; Aihara, Masao; Nakazawa, Shinpei [Yamanashi Medical Univ., Tamaho (Japan)

    2002-09-01

    To determine whether there is sex difference in the growth of the frontal and prefrontal lobes, we quantitatively measured the volume of these lobes by three dimensional (3-D) MRI in healthy 12 males (5 months to 39 years) and six females (1 year 11 months to 27 years). The left and right lobes were studied separately. The 3-D MRI data were acquired by the fast spoiled gradient recalled (SPGR) sequence using a 1.5 T MR imager. The frontal and prefrontal lobe volumes were measured by the volume measurement function of the Workstation. In males, the left to right ratio (L/R ratio) of the frontal and prefrontal lobes increased with age. On the contrary, in females, L/R ratio of the frontal and prefrontal lobes showed no significant change with advancing age. These results highlighted sex-specific maturational changes of the frontal and prefrontal lobes and suggested that quantitative data on the frontal and prefrontal lobe are important in interpreting brain abnormalities in children with developmental disorders. (author)

  8. Measurements of the frontal and prefrontal lobe volumes by three dimensional magnetic resonance imaging scan. III. Analysis of sex differences with advanced age

    International Nuclear Information System (INIS)

    Kanemura, Hideaki; Aihara, Masao; Nakazawa, Shinpei

    2002-01-01

    To determine whether there is sex difference in the growth of the frontal and prefrontal lobes, we quantitatively measured the volume of these lobes by three dimensional (3-D) MRI in healthy 12 males (5 months to 39 years) and six females (1 year 11 months to 27 years). The left and right lobes were studied separately. The 3-D MRI data were acquired by the fast spoiled gradient recalled (SPGR) sequence using a 1.5 T MR imager. The frontal and prefrontal lobe volumes were measured by the volume measurement function of the Workstation. In males, the left to right ratio (L/R ratio) of the frontal and prefrontal lobes increased with age. On the contrary, in females, L/R ratio of the frontal and prefrontal lobes showed no significant change with advancing age. These results highlighted sex-specific maturational changes of the frontal and prefrontal lobes and suggested that quantitative data on the frontal and prefrontal lobe are important in interpreting brain abnormalities in children with developmental disorders. (author)

  9. Preliminary results of the seventh three-dimensional AER dynamic benchmark problem calculation. Solution with DYN3D and RELAP5-3D codes

    International Nuclear Information System (INIS)

    Bencik, M.; Hadek, J.

    2011-01-01

    The paper gives a brief survey of the seventh three-dimensional AER dynamic benchmark calculation results received with the codes DYN3D and RELAP5-3D at Nuclear Research Institute Rez. This benchmark was defined at the twentieth AER Symposium in Hanassari (Finland). It is focused on investigation of transient behaviour in a WWER-440 nuclear power plant. Its initiating event is opening of the main isolation valve and re-connection of the loop with its main circulation pump in operation. The WWER-440 plant is at the end of the first fuel cycle and in hot full power conditions. Stationary and burnup calculations were performed with the code DYN3D. Transient calculation was made with the system code RELAP5-3D. The two-group homogenized cross sections library HELGD05 created by HELIOS code was used for the generation of reactor core neutronic parameters. The detailed six loops model of NPP Dukovany was adopted for the seventh AER dynamic benchmark purposes. The RELAP5-3D full core neutronic model was coupled with 49 core thermal-hydraulic channels and 8 reflector channels connected with the three-dimensional model of the reactor vessel. The detailed nodalization of reactor downcomer, lower and upper plenum was used. Mixing in lower and upper plenum was simulated. The first part of paper contains a brief characteristic of RELAP5-3D system code and a short description of NPP input deck and reactor core model. The second part shows the time dependencies of important global and local parameters. (Authors)

  10. Effects of three-dimensional conformal radiotherapy, indensity modulated radiotherapy, and conventional radiotherapy ON treatment of esophageal cancer

    Directory of Open Access Journals (Sweden)

    Jian-Jun Han

    2016-07-01

    Full Text Available Objective: To compare the irradiation volume, short-term and long-term efficacy of conventional radiotherapy (CR, three-dimensional conformal radiotherapy (3D-CRT, and indensity modulated radiotherapy (IMRT in the treatment of esophageal cancer. Methods: A retrospective analysis method was adopted. The patients were divided into CR group (n=42, 3D-CRT group (n=45, and IMRT group (n=40. A follow-up visit was paid to collect the short-term and long-term efficacy, and the occurrence of adverse reactions. The gross tumor voluem (GTV, clinical target volume (CTV, planning target volume (PTV, and irradiation volume of organs (bilateral lungs, spinal cord, and heart at risk (OAR in the three groups were compared. Results: It was found by target volume comparison that the mean values of GTV, CTV, and PTV in the three groups were significantly increased (P0.05. The occurrence rate of adverse reactions in 3D-CRT group and IMRT group was significantly lower than that in CR group (P0.05. The difference of 1-year survival rate among the three groups was not statistically significant (P=0.144, but 3-year and 5-year survival rates in 3D-CRT group and IMRT group were significantly higher than those in CR group (P<0.05. Conclusions: 3D-CRT and IMRT can significantly enhance the short-term and long-term efficacy for esophageal cancer patients, and alleviate the radioactive damage; therefore, they are deserved to be widely recommended in the clinic.

  11. Three-dimensional particle image velocimetry measurement technique

    International Nuclear Information System (INIS)

    Hassan, Y.A.; Seeley, C.H.; Henderson, J.A.; Schmidl, W.D.

    2004-01-01

    The experimental flow visualization tool, Particle Image Velocimetry (PIV), is being used to determine the velocity field in two-dimensional fluid flows. In the past few years, the technique has been improved to allow the capture of flow fields in three dimensions. This paper describes changes which were made to two existing two-dimensional tracking algorithms to enable them to track three-dimensional PIV data. Results of the tests performed on these three-dimensional routines with synthetic data are presented. Experimental data was also used to test the tracking algorithms. The test setup which was used to acquire the three-dimensional experimental data is described, along with the results from both of the tracking routines which were used to analyze the experimental data. (author)

  12. Transient Three-Dimensional Side Load Analysis of Out-of-Round Film Cooled Nozzles

    Science.gov (United States)

    Wang, Ten-See; Lin, Jeff; Ruf, Joe; Guidos, Mike

    2010-01-01

    The objective of this study is to investigate the effect of nozzle out-of-roundness on the transient startup side loads at a high altitude, with an anchored computational methodology. The out-of-roundness could be the result of asymmetric loads induced by hardware attached to the nozzle, asymmetric internal stresses induced by previous tests, and deformation, such as creep, from previous tests. The rocket engine studied encompasses a regeneratively cooled thrust chamber and a film cooled nozzle extension with film coolant distributed from a turbine exhaust manifold. The computational methodology is based on an unstructured-grid, pressure-based computational fluid dynamics formulation, and a transient inlet history based on an engine system simulation. Transient startup computations were performed with the out-of-roundness achieved by four different degrees of ovalization: one perfectly round, one slightly out-of-round, one more out-of-round, and one significantly out-of-round. The results show that the separation-line-jump is the peak side load physics for the round, slightly our-of-round, and more out-of-round cases, and the peak side load increases as the degree of out-of-roundness increases. For the significantly out-of-round nozzle, however, the peak side load reduces to comparable to that of the round nozzle and the separation line jump is not the peak side load physics. The counter-intuitive result of the significantly out-of-round case is found to be related to a side force reduction mechanism that splits the effect of the separation-line-jump into two parts, not only in the circumferential direction and most importantly in time.

  13. Follow-up on Small Abdominal Aortic Aneurysms Using Three Dimensional Ultrasound

    DEFF Research Database (Denmark)

    Ghulam, Q. M.; Bredahl, K. K.; Lönn, L.

    2017-01-01

    Objectives Rupture risk in abdominal aortic aneurysms (AAAs) is assessed using AAA diameter; yet 10% of ruptures occur in a small aneurysm. This underlines the inadequacy of diameter as a standalone parameter. In this prospective follow-up study, ultrasound determined aneurysm diameter was compared...... with aneurysm volume determined by three dimensional ultrasound (3D-US) in a group of 179 AAAs. Design This was a prospective cohort study with repeated diameter and volume measurements by 3D-US. Material and methods In total, 179 patients with small infrarenal AAAs (diameter 30–55 mm) were enrolled......L) were recorded. In post-hoc analysis, it was found that more AAAs with a stable diameter and a growing volume than AAAs with a stable diameter and volume were undergoing aortic repair during follow-up, based on the maximum diameter. Conclusion In this cohort of small AAAs, 40% of patients with a stable...

  14. Structures of two-dimensional three-body systems

    International Nuclear Information System (INIS)

    Ruan, W.Y.; Liu, Y.Y.; Bao, C.G.

    1996-01-01

    Features of the structure of L = 0 states of a two-dimensional three-body model system have been investigated. Three types of permutation symmetry of the spatial part, namely symmetric, antisymmetric, and mixed, have been considered. A comparison has been made between the two-dimensional system and the corresponding three-dimensional one. The effect of symmetry on microscopic structures is emphasized. (author)

  15. Three dimensional flow phenomena in fluid machinery; Proceedings of the winter annual meeting, Miami Beach, FL, November 17-22, 1985

    International Nuclear Information System (INIS)

    Hamed, A.; Herring, J.; Povinelli, L.

    1985-01-01

    Papers in this volume provide an overview of the latest developments in experimental measurements and analytical and numerical predictions of three-dimensional flows in fluid machinery. Topics discussed include three-dimensional cascade testing of turbine nozzles at high exit Mach number; the use of a secondary flow computation in the compressor design process; an experimental investigation of static propeller flow field; and calculation of three-dimensional boundary layers on rotating turbine blades. Papers are also presented on a three-dimensional solution method for turbomachinery analysis; analysis of rotational inviscid flows in curved passages; and a mathematical model for the analysis of fluid flow in a scroll

  16. Three-dimensional architecture of the whole human soleus muscle in vivo

    Science.gov (United States)

    Finni, Taija; D’Souza, Arkiev; Eguchi, Junya; Clarke, Elizabeth C.; Herbert, Robert D.

    2018-01-01

    Background Most data on the architecture of the human soleus muscle have been obtained from cadaveric dissection or two-dimensional ultrasound imaging. We present the first comprehensive, quantitative study on the three-dimensional anatomy of the human soleus muscle in vivo using diffusion tensor imaging (DTI) techniques. Methods We report three-dimensional fascicle lengths, pennation angles, fascicle curvatures, physiological cross-sectional areas and volumes in four compartments of the soleus at ankle joint angles of 69 ± 12° (plantarflexion, short muscle length; average ± SD across subjects) and 108 ± 7° (dorsiflexion, long muscle length) of six healthy young adults. Microdissection and three-dimensional digitisation on two cadaveric muscles corroborated the compartmentalised structure of the soleus, and confirmed the validity of DTI-based muscle fascicle reconstructions. Results The posterior compartments of the soleus comprised 80 ± 5% of the total muscle volume (356 ± 58 cm3). At the short muscle length, the average fascicle length, pennation angle and curvature was 37 ± 8 mm, 31 ± 3° and 17 ± 4 /m, respectively. We did not find differences in fascicle lengths between compartments. However, pennation angles were on average 12° larger (p < 0.01) in the posterior compartments than in the anterior compartments. For every centimetre that the muscle-tendon unit lengthened, fascicle lengths increased by 3.7 ± 0.8 mm, pennation angles decreased by −3.2 ± 0.9° and curvatures decreased by −2.7 ± 0.8 /m. Fascicles in the posterior compartments rotated almost twice as much as in the anterior compartments during passive lengthening. Discussion The homogeneity in fascicle lengths and inhomogeneity in pennation angles of the soleus may indicate a functionally different role for the anterior and posterior compartments. The data and techniques presented here demonstrate how DTI can be used to obtain detailed, quantitative measurements of the

  17. COMMIX-1AR/P: A three-dimensional transient single-phase computer program for thermal hydraulic analysis of single and multicomponent systems. Volume 2, User`s guide

    Energy Technology Data Exchange (ETDEWEB)

    Garner, P.L.; Blomquist, R.N.; Gelbard, E.M.

    1992-09-01

    The COMMIX-1AR/P computer program is designed for analyzing the steady-state and transient aspects of single-phase fluid flow and heat transfer in three spatial dimensions. This version is an extension of the modeling in COMMIX-1A to include multiple fluids in physically separate regions of the computational domain, modeling descriptions for pumps, radiation heat transfer between surfaces of the solids which are embedded in or surround the fluid, a k-{var_epsilon} model for fluid turbulence, and improved numerical techniques. The porous-medium formulation in COMMIX allows the program to be applied to a wide range of problems involving both simple and complex geometrical arrangements. The input preparation and execution procedures are presented for the COMMIX-1AR/P program and several postprocessor programs which produce graphical displays of the calculated results.

  18. Investigation on Capacitor Switching Transient Limiter with a Three phase Variable Resistance

    DEFF Research Database (Denmark)

    Naderi, Seyed Behzad; Jafari, Mehdi; Zandnia, Amir

    2017-01-01

    In this paper, a capacitor switching transient limiter based on a three phase variable resistance is proposed. The proposed structure eliminates the capacitor switching transient current and over-voltage by introducing a variable resistance to the current path with its special switching pattern...... transients on capacitor after bypassing. Analytic Analyses for this structure in transient cases are presented in details and simulations are performed by MATLAB software to prove its effectiveness....

  19. Three-dimensional excitation and emission matrix fluorescence (3DEEM) for quick and pseudo-quantitative determination of protein- and humic-like substances in full-scale membrane bioreactor (MBR).

    Science.gov (United States)

    Jacquin, Céline; Lesage, Geoffroy; Traber, Jacqueline; Pronk, Wouter; Heran, Marc

    2017-07-01

    The goal of this study is to help filling the research gaps linked to the on-line application of fluorescence spectroscopy in wastewater treatment and data processing tools suitable for rapid correction and extraction of data contained in three-dimensional fluorescence excitation-emission matrix (3DEEM) for real-time studies. 3DEEM was evaluated for direct quantification of Effluent Organic Matter (EfOM) fractions in full-scale MBR bulk supernatant and permeate samples. Principal Component Analysis (PCA) was used to investigate possible correlations between conventional Lowry and Dubois methods, Liquid Chromatography coupled to Organic Carbon and Organic Nitrogen Detection (LC-OCD-OND) and 3DEEM. 3DEEM data were analyzed using the volume of fluorescence (Φ) parameter from the Fluorescence Regional Integration (FRI) method. Two mathematical correlations were established between LC-OCD-OND and 3DEEM data to quantify protein-like and humic-like substances. These correlations were validated with supplementary data from the initial full-scale MBR, and were checked with samples from other systems (a second full-scale MBR, a full-scale conventional activated sludge (CAS) and a laboratory-scale MBR). While humic-like correlation showed satisfactory prediction for a second full-scale MBR and a CAS system, further studies are required for protein-like estimation in other systems. This new approach offers interesting perspectives for the on-line application of 3DEEM for EfOM quantification (protein-like and humic-like substances), fouling prediction and MBR process control. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Interim results of the sixth three-dimensional AER dynamic benchmark problem calculation. Solution of problem with DYN3D and RELAP5-3D codes

    International Nuclear Information System (INIS)

    Hadek, J.; Kral, P.; Macek, J.

    2001-01-01

    The paper gives a brief survey of the 6 th three-dimensional AER dynamic benchmark calculation results received with the codes DYN3D and RELAPS-3D at NRI Rez. This benchmark was defined at the 10 th AER Symposium. Its initiating event is a double ended break in the steam line of steam generator No. I in a WWER-440/213 plant at the end of the first fuel cycle and in hot full power conditions. Stationary and burnup calculations as well as tuning of initial state before the transient were performed with the code DYN3D. Transient calculations were made with the system code RELAPS-3D.The KASSETA library was used for the generation of reactor core neutronic parameters. The detailed six loops model of NPP Dukovany was adopted for the 6 th AER dynamic benchmark purposes. The RELAPS-3D full core neutronic model was connected with seven coolant channels thermal-hydraulic model of the core (Authors)

  1. Instantaneous three-dimensional visualization of concentration distributions in turbulent flows with crossed-plane laser-induced fluorescence imaging

    Science.gov (United States)

    Hoffmann, A.; Zimmermann, F.; Scharr, H.; Krömker, S.; Schulz, C.

    2005-01-01

    A laser-based technique for measuring instantaneous three-dimensional species concentration distributions in turbulent flows is presented. The laser beam from a single laser is formed into two crossed light sheets that illuminate the area of interest. The laser-induced fluorescence (LIF) signal emitted from excited species within both planes is detected with a single camera via a mirror arrangement. Image processing enables the reconstruction of the three-dimensional data set in close proximity to the cutting line of the two light sheets. Three-dimensional intensity gradients are computed and compared to the two-dimensional projections obtained from the two directly observed planes. Volume visualization by digital image processing gives unique insight into the three-dimensional structures within the turbulent processes. We apply this technique to measurements of toluene-LIF in a turbulent, non-reactive mixing process of toluene and air and to hydroxyl (OH) LIF in a turbulent methane-air flame upon excitation at 248 nm with a tunable KrF excimer laser.

  2. Studies on three-dimensional reproduction of maxillofacial cranium shape, 2

    International Nuclear Information System (INIS)

    Mihara, Manabu

    1984-01-01

    The purpose of the serial studies were to develop a three-dimensional reproduction for diagnosis and surgical therapy planning. In the present study, the author devised the methd of making models reproduced through applying high resolutional computed tomography (GE CT/T). Preliminary examinations were carried out on the CT numbers and on the measurement of CT film images for three-dimensional reproduction. The results are summarized below: 1) There were few hourly changes of CT numbers. 2) At the interspace of the phantom teflon rod and water, CT numbers changed gradually because of the partial volume effect and the edge response. Although the true boundaries of the materials could be indentified with the median CT number of the two substances. 3) Setting up to 1,000 on the window level and 1,200 on the window width, the measurement value of the views of the phantom teflon rod which had been magnified 1.8 power coincided with the true size. 4) Supplementary examinations were carried out on the same methods using a pig mandible, and the results were affirmed. The models were made of acrilic boards which the images of CT films were traced. Those boards were waxed up and trimmed in the boxies for three-dimensional reproduction by using cephalograms. The reproducible accuracy of the completed models was satisfactory for use in the field of the maxillofacial surgery. (author)

  3. Elastocapillary fabrication of three-dimensional microstructures

    NARCIS (Netherlands)

    van Honschoten, J.W.; Berenschot, Johan W.; Ondarcuhu, T.; Sanders, Remco G.P.; Sundaram, J.; Elwenspoek, Michael Curt; Tas, Niels Roelof

    2010-01-01

    We describe the fabrication of three-dimensional microstructures by means of capillary forces. Using an origami-like technique, planar silicon nitride structures of various geometries are folded to produce three-dimensional objects of 50–100 m. Capillarity is a particularly effective mechanism since

  4. CT-guided intracavitary radiotherapy for cervical cancer: Comparison of conventional point A plan with clinical target volume-based three-dimensional plan using dose-volume parameters

    International Nuclear Information System (INIS)

    Shin, Kyung Hwan; Kim, Tae Hyun; Cho, Jung Keun; Kim, Joo-Young; Park, Sung Yong; Park, Sang-Yoon; Kim, Dae Yong; Chie, Eui Kyu; Pyo, Hong Ryull; Cho, Kwan Ho

    2006-01-01

    2.15, respectively. Statistical analysis showed that the conformal index and external volume index improved significantly with the CTV plan, and this improvement was more marked in Group 1. The mean values of the bladder and rectal point doses and volume fractions receiving 50%, 80%, and 100% of the reference dose did not differ between plans for all patients. The reduction in the mean rectal and bladder point doses and irradiated volumes for the CTV plan was statistically significant in Group 1. Conclusion: Computed tomography-guided CTV planning of ICR is superior to conventional point A planning in terms of conformity of target coverage and avoidance of overdosed normal tissue volume. To ascertain the potential benefit of treatment outcome, ICR with image-guided three-dimensional plans will be pursued and correlated with the dose-volume parameters

  5. Three-dimensional geometric analysis of felid limb bone allometry.

    Directory of Open Access Journals (Sweden)

    Michael Doube

    Full Text Available Studies of bone allometry typically use simple measurements taken in a small number of locations per bone; often the midshaft diameter or joint surface area is compared to body mass or bone length. However, bones must fulfil multiple roles simultaneously with minimum cost to the animal while meeting the structural requirements imposed by behaviour and locomotion, and not exceeding its capacity for adaptation and repair. We use entire bone volumes from the forelimbs and hindlimbs of Felidae (cats to investigate regional complexities in bone allometry.Computed tomographic (CT images (16435 slices in 116 stacks were made of 9 limb bones from each of 13 individuals of 9 feline species ranging in size from domestic cat (Felis catus to tiger (Panthera tigris. Eleven geometric parameters were calculated for every CT slice and scaling exponents calculated at 5% increments along the entire length of each bone. Three-dimensional moments of inertia were calculated for each bone volume, and spherical radii were measured in the glenoid cavity, humeral head and femoral head. Allometry of the midshaft, moments of inertia and joint radii were determined. Allometry was highly variable and related to local bone function, with joint surfaces and muscle attachment sites generally showing stronger positive allometry than the midshaft.Examining whole bones revealed that bone allometry is strongly affected by regional variations in bone function, presumably through mechanical effects on bone modelling. Bone's phenotypic plasticity may be an advantage during rapid evolutionary divergence by allowing exploitation of the full size range that a morphotype can occupy. Felids show bone allometry rather than postural change across their size range, unlike similar-sized animals.

  6. Brain lesion analysis using three-dimensional SPECT imaging

    International Nuclear Information System (INIS)

    Shibata, Iekado; Onagi, Atsuo; Kuroki, Takao

    1995-01-01

    A three-headed gamma camera (PRISM 3000) is capable to scan the protocol of early dynamic SPECT and to analyze two radioisotopes at the same time. We have framed three-dimensional brain SPECT images for several brain diseases by using the Application Visualization System (AVS). We carried out volume measurements in brain tumors and/or AVMs by applying this methodology. Thallium-201 and/or 123I-IMP were used for brain SPECT imaging. The dynamic scan protocol was changed in accordance with the given disease. The protocol for brain tumors was derived from a preliminary comparative study with thallium-201 and 123I-IMP that had suggested a disparity in the detection of brain tumors and the differentiation between tumor tissue and normal brain. The three-dimension SPECT image represented the brain tumor or AVM in a striking fashion, and the changes with respect to tumor or AVM after radiosurgery or embolization were understood readily. (author)

  7. LLUVIA-II: A program for two-dimensional, transient flow through partially saturated porous media

    International Nuclear Information System (INIS)

    Eaton, R.R.; Hopkins, P.L.

    1992-08-01

    LLUVIA-II is a program designed for the efficient solution of two- dimensional transient flow of liquid water through partially saturated, porous media. The code solves Richards equation using the method-of-lines procedure. This document describes the solution procedure employed, input data structure, output, and code verification

  8. Three dimensional modeling on airflow, heat and mass transfer in partially impermeable enclosure containing agricultural produce during natural convective cooling

    International Nuclear Information System (INIS)

    Chourasia, M.K.; Goswami, T.K.

    2007-01-01

    A three dimensional model was developed to simulate the transport phenomena in heat and mass generating porous medium cooled under natural convective environment. Unlike the previous works on this aspect, the present model was aimed for bulk stored agricultural produce contained in a permeable package placed on a hard surface. This situation made the bottom of the package impermeable to fluid flow as well as moisture transfer and adiabatic to heat transfer. The velocity vectors, isotherms and contours of rate of moisture loss were presented during transient cooling as well as at steady state using the commercially available computational fluid dynamics (CFD) code based on the finite volume technique. The CFD model was validated using the experimental data on the time-temperature history as well as weight loss obtained from a bag of potatoes kept in a cold store. The simulated and experimental values on temperature and moisture loss of the product were found to be in good agreement

  9. Ionizing Shocks in Argon. Part 2: Transient and Multi-Dimensional Effects (Preprint)

    Science.gov (United States)

    2010-09-09

    stability in ionizing monatomic gases. Part 1. Argon ,” J. Fluid Mech., 84, 55 (1978). 2M. P. F. Bristow and I. I. Glass, “ Polarizability of singly...Article 3. DATES COVERED (From - To) 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Ionizing Shocks in Argon . Part 2: Transient...Physics. 14. ABSTRACT We extend the computations of ionizing shocks in argon to unsteady and multi-dimensional, using a collisional-radiative

  10. Three-dimensional printing and pediatric liver disease.

    Science.gov (United States)

    Alkhouri, Naim; Zein, Nizar N

    2016-10-01

    Enthusiastic physicians and medical researchers are investigating the role of three-dimensional printing in medicine. The purpose of the current review is to provide a concise summary of the role of three-dimensional printing technology as it relates to the field of pediatric hepatology and liver transplantation. Our group and others have recently demonstrated the feasibility of printing three-dimensional livers with identical anatomical and geometrical landmarks to the native liver to facilitate presurgical planning of complex liver surgeries. Medical educators are exploring the use of three-dimensional printed organs in anatomy classes and surgical residencies. Moreover, mini-livers are being developed by regenerative medicine scientist as a way to test new drugs and, eventually, whole livers will be grown in the laboratory to replace organs with end-stage disease solving the organ shortage problem. From presurgical planning to medical education to ultimately the bioprinting of whole organs for transplantation, three-dimensional printing will change medicine as we know in the next few years.

  11. A Semi-implicit Numerical Scheme for a Two-dimensional, Three-field Thermo-Hydraulic Modeling

    International Nuclear Information System (INIS)

    Hwang, Moonkyu; Jeong, Jaejoon

    2007-07-01

    The behavior of two-phase flow is modeled, depending on the purpose, by either homogeneous model, drift flux model, or separated flow model, Among these model, in the separated flow model, the behavior of each flow phase is modeled by its own governing equation, together with the interphase models which describe the thermal and mechanical interactions between the phases involved. In this study, a semi-implicit numerical scheme for two-dimensional, transient, two-fluid, three-field is derived. The work is an extension to the previous study for the staggered, semi-implicit numerical scheme in one-dimensional geometry (KAERI/TR-3239/2006). The two-dimensional extension is performed by specifying a relevant governing equation set and applying the related finite differencing method. The procedure for employing the semi-implicit scheme is also described in detail. Verifications are performed for a 2-dimensional vertical plate for a single-phase and two-phase flows. The calculations verify the mass and energy conservations. The symmetric flow behavior, for the verification problem, also confirms the momentum conservation of the numerical scheme

  12. Processing and display of three-dimensional arrays of numerical data using octree encoding

    International Nuclear Information System (INIS)

    Amans, J.L.; Antoine, M.; Darier, P.

    1986-04-01

    The analysis of three-dimensional (3-D) arrays of numerical data from medical, industrial or scientific imaging, by synthetic generation of realistic images, has been widely developed. The Octree encoding, that organizes the volume data in a hierarchical tree structure, has some interesting features for 3-D arrays of data processing. The Octree encoding method, based on the recursive subdivision of a 3-D array, is an extension of the Quadtree encoding in the two-dimensional plane. We have developed a software package to validate the basic Octree encoding methodology for some manipulation and display operations of volume data. The contribution introduces the technique we have used (called ''overlay technique'') to make the projection operation of an Octree on a Quadtree encoded image plane. The application of this technique to the hidden surface display is presented [fr

  13. The distal femoral and proximal tibial growth plates: MR imaging, three-dimensional modeling and estimation of area and volume

    Energy Technology Data Exchange (ETDEWEB)

    Craig, Joseph G.; Holsbeeck, Marnix van [Department of Radiology, Henry Ford Hospital, Detroit, MI (United States); Cody, Dianna D. [Department of Imaging Physics, University of Texas, M.D. Anderson Hospital, Houston, TX (United States)

    2004-06-01

    To explore how the size of the growth plate changes with age using three-dimensional (3D) models of the distal femoral and proximal tibial growth plates in pediatric patients. We retrospectively created 3D models of the normal unaffected distal femoral (n=20) and proximal tibial (n=10) growth plates in 14 patients (9 males, 5 females) age range 3.8-15.6 years who were referred for evaluation of premature partial closure of the growth plate or hyaline cartilage abnormality. All patients had one or more 3D fat-suppressed spoiled GRASS sequence from which models were made of normal growth plates. Total projected area was estimated from standardized maximum intensity projection (MIP) views, and volume was computed from the entire model. We also included the total projected area of the distal femur (n=7) or proximal tibia (n=8) in 11 patients (8 males, 3 females, 5-13 years) who had previously been evaluated for bone bridging. The 3D femoral and tibial growth plate anatomy was displayed. Femoral growth plate area varied from 804 mm{sup 2} to 3,463 mm{sup 2}. Femoral physeal cartilage volume varied from 2.1 cm{sup 3} to 12.6 cm{sup 3}. Tibial growth plate area varied from 736 mm{sup 2} to 3,026 mm{sup 2}. Tibial physeal cartilage volume varied from 1.9 cm{sup 3} to 13.2 cm{sup 3}. The growth plate area values appear to increase linearly with increasing age. (orig.)

  14. Analysis of Human Fibroadenomas Using Three-Dimensional Impedance Maps

    Science.gov (United States)

    Dapore, Alexander J.; King, Michael R.; Harter, Josephine; Sarwate, Sandhya; Oelze, Michael L.; Zagzebski, James A.; Do, Minh N.; Hall, Timothy J.

    2012-01-01

    Three-dimensional impedance maps (3DZMs) are virtual volumes of acoustic impedance values constructed from histology to represent tissue microstructure acoustically. From the 3DZM, the ultrasonic backscattered power spectrum can be predicted and model based scatterer properties, such as effective scatterer diameter (ESD), can be estimated. Additionally, the 3DZM can be exploited to visualize and identify possible scattering sites, which may aid in the development of more effective scattering models to better represent the ultrasonic interaction with underlying tissue microstructure. In this study, 3DZMs were created from a set of human fibroadenoma samples. ESD estimates were made assuming a fluid-filled sphere form factor model from 3DZMs of volume 300 × 300 × 300 µm. For a collection of 33 independent human fibroadenoma tissue samples, the ESD was estimated to be 111 ± 40.7 µm. The 3DZMs were then investigated visually to identify possible scattering sources which conformed to the estimated model scatterer dimensions. This estimation technique allowed a better understanding of the spatial distribution and variability of the estimates throughout the volume. PMID:21278015

  15. Two-dimensional particle simulation of negative ion extraction from a volume source

    International Nuclear Information System (INIS)

    Naitou, H.; Fukumasa, O.; Sakachou, K.; Mutou, K.

    1995-01-01

    Two-dimensional electrostatic particle simulation was done to study the extraction of negative ions from a volume plasma source. The simulation model is a rectangular system which consists of an extraction grid, a plasma grid, and a grounded wall. Full dynamics of electrons, ions, and negative ions are followed. Negative ions are extracted from the plasma region to the extraction grid through a slit in the plasma grid. For the lower value of extraction grid potential, the simulation results agree with the Child-Langumuir law, where the extracted negative ion current is proportional to the three-halves power of the potential of the extraction grid. For the higher value of extraction grid potential, the space charge effect of negative ions, which enter into the beamline at the top of the concavity of the positive ion boundary, reduces the negative ion current from the prediction of the Child-Langumuir law. ((orig.))

  16. Three-dimensional three-component particle velocimetry for microscale flows using volumetric scanning

    International Nuclear Information System (INIS)

    Klein, S A; Moran, J L; Posner, J D; Frakes, D H

    2012-01-01

    We present a diagnostic platform for measuring three-dimensional three-component (3D3C) velocity fields in microscopic volumes. The imaging system uses high-speed Nipkow spinning disk confocal microscopy. Confocal microscopy provides optical sectioning using pinhole spatial filtering which rejects light originating from out-of-focus objects. The system accomplishes volumetric scanning by rapid translation of the high numerical aperture objective using a piezo objective positioner. The motion of fluorescent microspheres is quantified using 3D3C super resolution particle-imaging velocimetry with instantaneous spatial resolutions of the order of 5 µm or less in all three dimensions. We examine 3D3C flow in a PDMS microchannel with an expanding section at 3D acquisition rates of 30 Hz, and find strong agreement with a computational model. Equations from the PIV and PTV literature adapted for a scanning objective provide estimates of maximum measurable velocity. The technique allows for isosurface visualization of 3D particle motion and robust high spatial resolution velocity measurements without requiring a calibration step or reconstruction algorithms. (paper)

  17. Studying the Recent Improvements in Holograms for Three-Dimensional Display

    Directory of Open Access Journals (Sweden)

    Hamed Abbasi

    2014-01-01

    Full Text Available Displayers tend to become three-dimensional. The most advantage of holographic 3D displays is the possibility to observe 3D images without using glasses. The quality of created images by this method has surprised everyone. In this paper, the experimental steps of making a transmission hologram have been mentioned. In what follows, current advances of this science-art will be discussed. The aim of this paper is to study the recent improvements in creating three-dimensional images and videos by means of holographic techniques. In the last section we discuss the potentials of holography to be applied in future.

  18. Application of Simulated Three Dimensional CT Image in Orthognathic Surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Don; Park, Chang Seo [Dept. of Dental Radiology, College of Dentistry, Yensei University, Seoul (Korea, Republic of); Yoo, Sun Kook; Lee, Kyoung Sang [Dept. of Medical Engineering, College of Medicine, Yensei University, Seoul (Korea, Republic of)

    1998-08-15

    In orthodontics and orthognathic surgery, cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery, too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipment and because of its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram, pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms, and for validation of new method, in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery, computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of

  19. Application of Simulated Three Dimensional CT Image in Orthognathic Surgery

    International Nuclear Information System (INIS)

    Kim, Hyun Don; Park, Chang Seo; Yoo, Sun Kook; Lee, Kyoung Sang

    1998-01-01

    In orthodontics and orthognathic surgery, cephalogram has been routine practice in diagnosis and treatment evaluation of craniofacial deformity. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. Therefore, it is desirable that three dimensional object is diagnosed and evaluated three dimensionally and three dimensional CT image is best for three dimensional analysis. Development of clinic necessitates evaluation of result of treatment and comparison before and after surgery. It is desirable that patient that was diagnosed and planned by three dimensional computed tomography before surgery is evaluated by three dimensional computed tomography after surgery, too. But Because there is no standardized normal values in three dimension now and three dimensional Computed Tomography needs expensive equipment and because of its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. If postoperative three dimensional image is constructed by pre and postoperative lateral and postero-anterior cephalograms and preoperative three dimensional computed tomogram, pre and postoperative image will be compared and evaluated three dimensionally without three dimensional computed tomography after surgery and that will contribute to standardize normal values in three dimension. This study introduced new method that computer-simulated three dimensional image was constructed by preoperative three dimensional computed tomogram and pre and postoperative lateral and postero-anterior cephalograms, and for validation of new method, in four cases of dry skull that position of mandible was displaced and four patients of orthognathic surgery, computer-simulated three dimensional image and actual postoperative three dimensional image were compared. The results were as follows. 1. In four cases of

  20. Three-Dimensional Glass Monolithic Micro-Flexure Fabricated by Femtosecond Laser Exposure and Chemical Etching

    Directory of Open Access Journals (Sweden)

    Viktor Tielen

    2014-09-01

    Full Text Available Flexures are components of micro-mechanisms efficiently replacing classical multi-part joints found at the macroscale. So far, flexures have been limited to two-dimensional planar designs due to the lack of a suitable three-dimensional micromanufacturing process. Here we demonstrate and characterize a high-strength transparent monolithic three-dimensional flexural component fabricated out of fused silica using non-ablative femtosecond laser processing combined with chemical etching. As an illustration of the potential use of this flexure, we propose a design of a Hoecken linkage entirely made with three-dimensional cross-spring pivot hinges.

  1. Three-dimensional measurement system for crime scene documentation

    Science.gov (United States)

    Adamczyk, Marcin; Hołowko, Elwira; Lech, Krzysztof; Michoński, Jakub; MÄ czkowski, Grzegorz; Bolewicki, Paweł; Januszkiewicz, Kamil; Sitnik, Robert

    2017-10-01

    Three dimensional measurements (such as photogrammetry, Time of Flight, Structure from Motion or Structured Light techniques) are becoming a standard in the crime scene documentation process. The usage of 3D measurement techniques provide an opportunity to prepare more insightful investigation and helps to show every trace in the context of the entire crime scene. In this paper we would like to present a hierarchical, three-dimensional measurement system that is designed for crime scenes documentation process. Our system reflects the actual standards in crime scene documentation process - it is designed to perform measurement in two stages. First stage of documentation, the most general, is prepared with a scanner with relatively low spatial resolution but also big measuring volume - it is used for the whole scene documentation. Second stage is much more detailed: high resolution but smaller size of measuring volume for areas that required more detailed approach. The documentation process is supervised by a specialised application CrimeView3D, that is a software platform for measurements management (connecting with scanners and carrying out measurements, automatic or semi-automatic data registration in the real time) and data visualisation (3D visualisation of documented scenes). It also provides a series of useful tools for forensic technicians: virtual measuring tape, searching for sources of blood spatter, virtual walk on the crime scene and many others. In this paper we present our measuring system and the developed software. We also provide an outcome from research on metrological validation of scanners that was performed according to VDI/VDE standard. We present a CrimeView3D - a software-platform that was developed to manage the crime scene documentation process. We also present an outcome from measurement sessions that were conducted on real crime scenes with cooperation with Technicians from Central Forensic Laboratory of Police.

  2. A self-consistent transport model for molecular conduction based on extended Huckel theory with full three-dimensional electrostatics

    DEFF Research Database (Denmark)

    Zahid, F.; Paulsson, Magnus; Polizzi, E.

    2005-01-01

    overlap) method and the electrostatic effects of metallic leads (bias and image charges) are included through a three-dimensional finite element method. This allows us to capture spatial details of the electrostatic potential profile, including effects of charging, screening, and complicated electrode...

  3. Comparação entre os volumes pulmonares irradiados com técnica bidimensional e tridimensional conformada na radioterapia de pacientes com tumores de pulmão localmente avançados Comparison between irradiated lung volumes with two-dimensional and three-dimensional conformal radiotherapy techniques for locally advanced lung cancer

    Directory of Open Access Journals (Sweden)

    Heloisa de Andrade Carvalho

    2009-10-01

    Full Text Available OBJETIVO: Comparar e quantificar os volumes pulmonares irradiados utilizando planejamentos bidimensional (2D e tridimensional (3D conformado na radioterapia de tumores de pulmão. MATERIAIS E MÉTODOS: Em 27 pacientes portadores de câncer de pulmão foi feito planejamento 3D e outro correspondente em 2D. As doses prescritas variaram de 45 a 66 Gy. Foram avaliadas as doses no volume alvo planejado (PTV, volume tumoral macroscópico (GTV e pulmões (volume de pulmão que recebe 20 Gy ou 30 Gy - V20 e V30, respectivamente, e dose média. Os órgãos de risco adjacentes (medula espinhal, esôfago e coração receberam doses abaixo dos limites de tolerância. RESULTADOS: O GTV variou de 10,5 a 1.290,0 cm³ (média de 189,65 cm³. Nos planejamentos 2D foi utilizado, em média, um total de 59,33 campos, e nos planejamentos 3D, 75,65 campos. Em todas as situações analisadas houve significante (p OBJECTIVE: To compare and quantify irradiated lung volumes using two-dimensional (2D and three-dimensional (3D conformal planning for radiotherapy in the treatment of lung cancer. MATERIALS AND METHODS: 2D and 3D conformal radiotherapy plannings were performed for 27 patients with lung cancer. Prescribed doses ranged from 45 to 66 Gy. The analysis covered the doses to planning target volume (PTV, gross tumor volume (GTV and lungs (lung volume receiving 20 Gy or 30 Gy - V20 and V30, respectively, and mean dose. The doses to adjacent organs at risk (spinal cord, esophagus and heart were maintained below the tolerance limits. RESULTS: GTV ranged from 10.5 to 1,290.0 cm³ (mean, 189.65 cm³. On average, a total of 59.33 fields were utilized in the 2D planning and 75.65 fields in the 3D planning. Lung volumes were significantly preserved (P < 0.05 with the 3D conformal planning in all the evaluated cases, with about 15% decrease in the irradiated lung volumes. Lungs without tumor were most benefited from this technique. CONCLUSION: 3D radiotherapy allowed a better

  4. Histopathology in 3D: From three-dimensional reconstruction to multi-stain and multi-modal analysis

    Directory of Open Access Journals (Sweden)

    Derek Magee

    2015-01-01

    Full Text Available Light microscopy applied to the domain of histopathology has traditionally been a two-dimensional imaging modality. Several authors, including the authors of this work, have extended the use of digital microscopy to three dimensions by stacking digital images of serial sections using image-based registration. In this paper, we give an overview of our approach, and of extensions to the approach to register multi-modal data sets such as sets of interleaved histopathology sections with different stains, and sets of histopathology images to radiology volumes with very different appearance. Our approach involves transforming dissimilar images into a multi-channel representation derived from co-occurrence statistics between roughly aligned images.

  5. Three-dimensional low-energy topological invariants

    International Nuclear Information System (INIS)

    Bakalarska, M.; Broda, B.

    2000-01-01

    A description of the one-loop approximation formula for the partition function of a three-dimensional abelian version of the Donaldson-Witten theory is proposed. The one-loop expression is shown to contain such topological invariants of a three-dimensional manifold M like the Reidemeister-Ray-Singer torsion τ R and Betti numbers. (orig.)

  6. Performance of new automated transthoracic three-dimensional echocardiographic software for left ventricular volumes and function assessment in routine clinical practice: Comparison with 3 Tesla cardiac magnetic resonance.

    Science.gov (United States)

    Levy, Franck; Dan Schouver, Elie; Iacuzio, Laura; Civaia, Filippo; Rusek, Stephane; Dommerc, Carinne; Marechaux, Sylvestre; Dor, Vincent; Tribouilloy, Christophe; Dreyfus, Gilles

    2017-11-01

    Three-dimensional (3D) transthoracic echocardiography (TTE) is superior to two-dimensional Simpson's method for assessment of left ventricular (LV) volumes and LV ejection fraction (LVEF). Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time-consuming. To evaluate the feasibility, accuracy and reproducibility of new fully automated fast 3D TTE software (HeartModel A.I. ; Philips Healthcare, Andover, MA, USA) for quantification of LV volumes and LVEF in routine practice; to compare the 3D LV volumes and LVEF obtained with a cardiac magnetic resonance (CMR) reference; and to optimize automated default border settings with CMR as reference. Sixty-three consecutive patients, who had comprehensive 3D TTE and CMR examinations within 24hours, were eligible for inclusion. Nine patients (14%) were excluded because of insufficient echogenicity in the 3D TTE. Thus, 54 patients (40 men; mean age 63±13 years) were prospectively included into the study. The inter- and intraobserver reproducibilities of 3D TTE were excellent (coefficient of variation<10%) for end-diastolic volume (EDV), end-systolic volume (ESV) and LVEF. Despite a slight underestimation of EDV using 3D TTE compared with CMR (bias=-22±34mL; P<0.0001), a significant correlation was found between the two measurements (r=0.93; P=0.0001). Enlarging default border detection settings leads to frequent volume overestimation in the general population, but improved agreement with CMR in patients with LVEF≤50%. Correlations between 3D TTE and CMR for ESV and LVEF were excellent (r=0.93 and r=0.91, respectively; P<0.0001). 3D TTE using new-generation fully automated software is a feasible, fast, reproducible and accurate imaging modality for LV volumetric quantification in routine practice. Optimization of border detection settings may increase agreement with CMR for EDV assessment in dilated ventricles. Copyright © 2017 Elsevier Masson

  7. Three dimensional non-linear cracking analysis of prestressed concrete containment vessel

    International Nuclear Information System (INIS)

    Al-Obaid, Y.F.

    2001-01-01

    The paper gives full development of three-dimensional cracking matrices. These matrices are simulated in three-dimensional non-linear finite element analysis adopted for concrete containment vessels. The analysis includes a combination of conventional steel, the steel line r and prestressing tendons and the anisotropic stress-relations for concrete and concrete aggregate interlocking. The analysis is then extended and is linked to cracking analysis within the global finite element program OBAID. The analytical results compare well with those available from a model test. (author)

  8. Transient analysis of scattering from ferromagnetic objects using Landau-Lifshitz-Gilbert and volume integral equations

    KAUST Repository

    Sayed, Sadeed Bin

    2016-11-02

    An explicit marching on-in-time scheme for analyzing transient electromagnetic wave interactions on ferromagnetic scatterers is described. The proposed method solves a coupled system of time domain magnetic field volume integral and Landau-Lifshitz-Gilbert (LLG) equations. The unknown fluxes and fields are discretized using full and half Schaubert-Wilton-Glisson functions in space and bandlimited temporal interpolation functions in time. The coupled system is cast in the form of an ordinary differential equation and integrated in time using a PE(CE)m type linear multistep method to obtain the unknown expansion coefficients. Numerical results demonstrating the stability and accuracy of the proposed scheme are presented.

  9. Transient analysis of scattering from ferromagnetic objects using Landau-Lifshitz-Gilbert and volume integral equations

    KAUST Repository

    Sayed, Sadeed Bin; Ulku, Huseyin Arda; Bagci, Hakan

    2016-01-01

    An explicit marching on-in-time scheme for analyzing transient electromagnetic wave interactions on ferromagnetic scatterers is described. The proposed method solves a coupled system of time domain magnetic field volume integral and Landau-Lifshitz-Gilbert (LLG) equations. The unknown fluxes and fields are discretized using full and half Schaubert-Wilton-Glisson functions in space and bandlimited temporal interpolation functions in time. The coupled system is cast in the form of an ordinary differential equation and integrated in time using a PE(CE)m type linear multistep method to obtain the unknown expansion coefficients. Numerical results demonstrating the stability and accuracy of the proposed scheme are presented.

  10. The future of three-dimensional medical imaging

    International Nuclear Information System (INIS)

    Peter, T.M.

    1996-01-01

    The past 15 years have witnessed an explosion in medical imaging technology, and none more so than in the tomographic imaging modalities of CT and MRI. Prior to 1975, 3-D imaging was largely performed in the minds of radiologists and surgeons, assisted by the modalities of conventional x-ray tomography and stereoscopic radiography. However today, with the advent of imaging techniques which ower their existence to computer technology, three-dimensional image acquisition is fast becoming the norm and the clinician finally has access to sets of data that represent the entire imaged volume. Stereoscopic image visualization has already begun to reappear as a viable means of visualizing 3 D medical images. The future of 3-D imaging is exciting and will undoubtedly move further in the direction of virtual reality. (author)

  11. Three-Component Forward Modeling for Transient Electromagnetic Method

    Directory of Open Access Journals (Sweden)

    Bin Xiong

    2010-01-01

    Full Text Available In general, the time derivative of vertical magnetic field is considered only in the data interpretation of transient electromagnetic (TEM method. However, to survey in the complex geology structures, this conventional technique has begun gradually to be unsatisfied with the demand of field exploration. To improve the integrated interpretation precision of TEM, it is necessary to study the three-component forward modeling and inversion. In this paper, a three-component forward algorithm for 2.5D TEM based on the independent electric and magnetic field has been developed. The main advantage of the new scheme is that it can reduce the size of the global system matrix to the utmost extent, that is to say, the present is only one fourth of the conventional algorithm. In order to illustrate the feasibility and usefulness of the present algorithm, several typical geoelectric models of the TEM responses produced by loop sources at air-earth interface are presented. The results of the numerical experiments show that the computation speed of the present scheme is increased obviously and three-component interpretation can get the most out of the collected data, from which we can easily analyze or interpret the space characteristic of the abnormity object more comprehensively.

  12. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization.

    Science.gov (United States)

    Pairleitner, H; Steiner, H; Hasenoehrl, G; Staudach, A

    1999-08-01

    To assess the feasibility of imaging low-velocity blood flow in adnexal masses by transvaginal three-dimensional power Doppler sonography, to analyze three-dimensional power Doppler sonography data sets with a new computer-assisted method and to test the reproducibility of the technique. A commercially available 5-MHz Combison 530 ultrasound system was used to perform three-dimensional power Doppler sonography transvaginally. A cube (= volume of interest) was defined enclosing the vessels of the cyst and the Cartesian characteristics were stored on a hard disk. This cube was analyzed using specially designed software. Five indices representing vascularization (the vascularization index (VI) or blood flow (the flow index (FI)) or both (the vascularization-flow index (VFI)) were calculated. The intraobserver repeatability of cube definition and scan repetition was assessed using Hartley's test for homogeneous variances. Interobserver agreement was assessed by the Pearson correlation coefficient. Imaging of vessels with low-velocity blood flow by three-dimensional power Doppler sonography and cube definition was possible in all adnexal massed studied. In some cases even induced non-vascular flow related to endometriosis was detected. The calculated F value with intraobserver repeated Cartesian file-saving ranged from 0 to 18.8, with intraobserver scan repetition from 4.74 to 24.8 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the calculated F value was 64. The interobserver correlation coefficient ranged between 0.83 and 0.92 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the correlation coefficient was less than 0.75. Vessels with low-velocity blood flow can be imaged using three-dimensional power Doppler sonography. Induced non-vascular flow was detected in endometriotic cyst fluid. Three-dimensional power Doppler sonography combined with the cube method gave reproducible information for all indices except VFI 2. These indices might prove to be a new predictor in all fields of

  13. Thermal analysis of LOFT modular DTT for LOCE transient

    International Nuclear Information System (INIS)

    Martin, C.M.

    1978-01-01

    A thermal analysis was performed on the LOFT modular drag-disc turbine transducer (MDTT) modular assembly. The purpose of this analysis was to determine the maximum temperature difference between the MDTT shroud and end cap during a LOCE. This temperature difference is needed for stress analysis of the MDTT endcap to fairing welds. The thermal analysis was done using TRIPLE, a three dimensional finite element code. A three dimensional model of the MDTT was made and transient temperature solutions were found for the different MDTT locations. The fluid temperature transients used for the solutions at all locations were from RELAP4 predictions of the LOFT L2-4 test which is considered the most severe temperature transient. Results of these calculations show the maximum temperature difference is 92 0 C (165 0 F) and occurs in the intact loop cold leg. This value and those found at other locations, are evaluated from the best available RELAP predicted temperatures during a nuclear LOCE

  14. Three-dimensional visualisation of the large bowel: a potential tool for assessing targeted drug delivery and colonic pathology

    International Nuclear Information System (INIS)

    Perkins, A.C.; Mann, C.; Wilson, C.G.

    1995-01-01

    A study has been undertaken to assess the feasibility of three-dimensional imaging of the dispersion of a non-absorbable tracer released into the colon of normal subjects. Six healthy volunteers were selected who were participating in a scintigraphic study designed to assess the spreading of 1 MBq indium-111 Amberlite resin delivered from a delayed capsule system targeted to release in the ascending colon. In each case subjects were imaged using a rotating gamma camera over a data collection period of approximately 20 min. Three-dimensional volume rendered images demonstrated good visualisation of the dispersion of the tracer throughout the ascending, transverse and descending colon and provided good anatomical visualisation of the shape of the colon, not previously apparent from the planar views. The present study demonstrates for the first time, the successful three-dimensional imaging of a radiolabelled tracer dispersed throughout the colon and opens up the prospects for more detailed study of quantification of the volume and distribution of tracers contained within the colon. (orig.). With 1 fig

  15. Radiological evaluation of the fetal face using three-dimensional ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Bäumler M

    2012-12-01

    Full Text Available Marcel Bäumler,1–3 Michèle Bigorre,1,4 Jean-Michel Faure1,51CHU Montpellier, Centre de Compétence des Fentes Faciales, Hôpital Lapeyronie, Montpellier, 2Clinique du Parc, Imagerie de la Femme, Castelnau-le-Lez, 3Cabinet de Radiologie du Trident, Lunel, 4CHU Service de Chirurgie Plastique Pédiatrique, Hôpital Lapeyronie, Montpellier, 5CHU Montpellier, Service de Gynécologie-Obstétrique, Hôpital Arnaud de Villeneuve, Montpellier, FranceAbstract: This paper reviews screening and three-dimensional diagnostic ultrasound imaging of the fetal face. The different techniques available for analyzing biometric and morphological items of the profile, eyes, ears, lips, and hard and soft palate are commented on and briefly compared with the respective bi-dimensional techniques. The available literature supports the use of three-dimensional ultrasound in difficult prenatal diagnostic conditions because of its diagnostic accuracy, enabling improved safety of perinatal care. Globally, a marked increase has been observed in the accuracy of three-dimensional ultrasound in comparison with the bi-dimensional approach. Because there is no consensus about the performance of the different three-dimensional techniques, future studies are needed in order to compare them and to find the best technique for analysis of each of the respective facial elements. Universal prenatal standards may integrate these potential new findings in the future. At this time, the existing guidelines for prenatal facial screening should not be changed.Keywords: prenatal three-dimensional ultrasound, prenatal screening, prenatal diagnosis, cleft lip and palate, fetal profile, retrognathism

  16. Two-dimensional capillary origami

    Energy Technology Data Exchange (ETDEWEB)

    Brubaker, N.D., E-mail: nbrubaker@math.arizona.edu; Lega, J., E-mail: lega@math.arizona.edu

    2016-01-08

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid. - Highlights: • Full solution set of the two-dimensional capillary origami problem. • Fluid does not necessarily wet the entire plate. • Global energy approach provides exact differential equations satisfied by minimizers. • Bifurcation diagrams highlight three different regimes. • Conditions for spontaneous encapsulation are identified.

  17. Two-dimensional capillary origami

    International Nuclear Information System (INIS)

    Brubaker, N.D.; Lega, J.

    2016-01-01

    We describe a global approach to the problem of capillary origami that captures all unfolded equilibrium configurations in the two-dimensional setting where the drop is not required to fully wet the flexible plate. We provide bifurcation diagrams showing the level of encapsulation of each equilibrium configuration as a function of the volume of liquid that it contains, as well as plots representing the energy of each equilibrium branch. These diagrams indicate at what volume level the liquid drop ceases to be attached to the endpoints of the plate, which depends on the value of the contact angle. As in the case of pinned contact points, three different parameter regimes are identified, one of which predicts instantaneous encapsulation for small initial volumes of liquid. - Highlights: • Full solution set of the two-dimensional capillary origami problem. • Fluid does not necessarily wet the entire plate. • Global energy approach provides exact differential equations satisfied by minimizers. • Bifurcation diagrams highlight three different regimes. • Conditions for spontaneous encapsulation are identified.

  18. Oblique water entry of a three dimensional body

    Directory of Open Access Journals (Sweden)

    Scolan Yves-Marie

    2014-12-01

    Full Text Available The problem of the oblique water entry of a three dimensional body is considered. Wagner theory is the theoretical framework. Applications are discussed for an elliptic paraboloid entering an initially flat free surface. A dedicated experimental campaign yields a data base for comparisons. In the present analysis, pressure, force and dynamics of the wetted surface expansion are assessed.

  19. Development of a reactivity worth correction scheme for the one-dimensional transient analysis

    International Nuclear Information System (INIS)

    Cho, J. Y.; Song, J. S.; Joo, H. G.; Kim, H. Y.; Kim, K. S.; Lee, C. C.; Zee, S. Q.

    2003-11-01

    This work is to develop a reactivity worth correction scheme for the MASTER one-dimensional (1-D) calculation model. The 1-D cross section variations according to the core state in the MASTER input file, which are produced for 1-D calculation performed by the MASTER code, are incorrect in most of all the core states except for exactly the same core state where the variations are produced. Therefore this scheme performs the reactivity worth correction factor calculations before the main 1-D transient calculation, and generates correction factors for boron worth, Doppler and moderator temperature coefficients, and control rod worth, respectively. These correction factors force the one dimensional calculation to generate the same reactivity worths with the 3-dimensional calculation. This scheme is applied to the control bank withdrawal accident of Yonggwang unit 1 cycle 14, and the performance is examined by comparing the 1-D results with the 3-D results. This problem is analyzed by the RETRAN-MASTER consolidated code system. Most of all results of 1-D calculation including the transient power behavior, the peak power and time are very similar with the 3-D results. In the MASTER neutronics computing time, the 1-D calculation including the correction factor calculation requires the negligible time comparing with the 3-D case. Therefore, the reactivity worth correction scheme is concluded to be very good in that it enables the 1-D calculation to produce the very accurate results in a few computing time

  20. Large three-dimensional photonic crystals based on monocrystalline liquid crystal blue phases.

    Science.gov (United States)

    Chen, Chun-Wei; Hou, Chien-Tsung; Li, Cheng-Chang; Jau, Hung-Chang; Wang, Chun-Ta; Hong, Ching-Lang; Guo, Duan-Yi; Wang, Cheng-Yu; Chiang, Sheng-Ping; Bunning, Timothy J; Khoo, Iam-Choon; Lin, Tsung-Hsien

    2017-09-28

    Although there have been intense efforts to fabricate large three-dimensional photonic crystals in order to realize their full potential, the technologies developed so far are still beset with various material processing and cost issues. Conventional top-down fabrications are costly and time-consuming, whereas natural self-assembly and bottom-up fabrications often result in high defect density and limited dimensions. Here we report the fabrication of extraordinarily large monocrystalline photonic crystals by controlling the self-assembly processes which occur in unique phases of liquid crystals that exhibit three-dimensional photonic-crystalline properties called liquid-crystal blue phases. In particular, we have developed a gradient-temperature technique that enables three-dimensional photonic crystals to grow to lateral dimensions of ~1 cm (~30,000 of unit cells) and thickness of ~100 μm (~ 300 unit cells). These giant single crystals exhibit extraordinarily sharp photonic bandgaps with high reflectivity, long-range periodicity in all dimensions and well-defined lattice orientation.Conventional fabrication approaches for large-size three-dimensional photonic crystals are problematic. By properly controlling the self-assembly processes, the authors report the fabrication of monocrystalline blue phase liquid crystals that exhibit three-dimensional photonic-crystalline properties.

  1. A finite volume solver for three dimensional debris flow simulations based on a single calibration parameter

    Science.gov (United States)

    von Boetticher, Albrecht; Turowski, Jens M.; McArdell, Brian; Rickenmann, Dieter

    2016-04-01

    Debris flows are frequent natural hazards that cause massive damage. A wide range of debris flow models try to cover the complex flow behavior that arises from the inhomogeneous material mixture of water with clay, silt, sand, and gravel. The energy dissipation between moving grains depends on grain collisions and tangential friction, and the viscosity of the interstitial fine material suspension depends on the shear gradient. Thus a rheology description needs to be sensitive to the local pressure and shear rate, making the three-dimensional flow structure a key issue for flows in complex terrain. Furthermore, the momentum exchange between the granular and fluid phases should account for the presence of larger particles. We model the fine material suspension with a Herschel-Bulkley rheology law, and represent the gravel with the Coulomb-viscoplastic rheology of Domnik & Pudasaini (Domnik et al. 2013). Both composites are described by two phases that can mix; a third phase accounting for the air is kept separate to account for the free surface. The fluid dynamics are solved in three dimensions using the finite volume open-source code OpenFOAM. Computational costs are kept reasonable by using the Volume of Fluid method to solve only one phase-averaged system of Navier-Stokes equations. The Herschel-Bulkley parameters are modeled as a function of water content, volumetric solid concentration of the mixture, clay content and its mineral composition (Coussot et al. 1989, Yu et al. 2013). The gravel phase properties needed for the Coulomb-viscoplastic rheology are defined by the angle of repose of the gravel. In addition to this basic setup, larger grains and the corresponding grain collisions can be introduced by a coupled Lagrangian particle simulation. Based on the local Savage number a diffusive term in the gravel phase can activate phase separation. The resulting model can reproduce the sensitivity of the debris flow to water content and channel bed roughness, as

  2. Three-dimensional conformal breast irradiation in the prone position

    Directory of Open Access Journals (Sweden)

    C. Kurtman

    2003-10-01

    Full Text Available The prone position can be used for the planning of adjuvant radiotherapy after conservative breast surgery in order to deliver less irradiation to lung and cardiac tissue. In the present study, we compared the results of three-dimensional conformal radiotherapy planning for five patients irradiated in the supine and prone position. Tumor stage was T1N0M0 in four patients and T1N1M0 in one. All patients had been previously submitted to conservative breast surgery. Breast size was large in three patients and moderate in the other two. Irradiation in the prone position was performed using an immobilization foam pad with a hole cut into it to accommodate the breast so that it would hang down away from the chest wall. Dose-volume histograms showed that mean irradiation doses reaching the ipsilateral lung were 8.3 ± 3.6 Gy with the patient in the supine position and 1.4 ± 1.0 Gy with the patient in the prone position (P = 0.043. The values for the contralateral lung were 1.3 ± 0.7 and 0.3 ± 0.1 Gy (P = 0.043 and the values for cardiac tissue were 4.6 ± 1.6 and 3.0 ± 1.7 Gy (P = 0.079, respectively. Thus, the dose-volume histograms demonstrated that lung tissue irradiation was significantly lower with the patient in the prone position than in the supine position. Large-breasted women appeared to benefit most from irradiation in the prone position. Prone position breast irradiation appears to be a simple and effective alternative to the conventional supine position for patients with large breasts, since they are subjected to lower pulmonary doses which may cause less pulmonary side effects in the future.

  3. Micro-computed tomography assessment of human alveolar bone: bone density and three-dimensional micro-architecture.

    Science.gov (United States)

    Kim, Yoon Jeong; Henkin, Jeffrey

    2015-04-01

    Micro-computed tomography (micro-CT) is a valuable means to evaluate and secure information related to bone density and quality in human necropsy samples and small live animals. The aim of this study was to assess the bone density of the alveolar jaw bones in human cadaver, using micro-CT. The correlation between bone density and three-dimensional micro architecture of trabecular bone was evaluated. Thirty-four human cadaver jaw bone specimens were harvested. Each specimen was scanned with micro-CT at resolution of 10.5 μm. The bone volume fraction (BV/TV) and the bone mineral density (BMD) value within a volume of interest were measured. The three-dimensional micro architecture of trabecular bone was assessed. All the parameters in the maxilla and the mandible were subject to comparison. The variables for the bone density and the three-dimensional micro architecture were analyzed for nonparametric correlation using Spearman's rho at the significance level of p architecture parameters were consistently higher in the mandible, up to 3.3 times greater than those in the maxilla. The most linear correlation was observed between BV/TV and BMD, with Spearman's rho = 0.99 (p = .01). Both BV/TV and BMD were highly correlated with all micro architecture parameters with Spearman's rho above 0.74 (p = .01). Two aspects of bone density using micro-CT, the BV/TV and BMD, are highly correlated with three-dimensional micro architecture parameters, which represent the quality of trabecular bone. This noninvasive method may adequately enhance evaluation of the alveolar bone. © 2013 Wiley Periodicals, Inc.

  4. Three-dimensional trajectory tracking for underactuated AUVs with bio-inspired velocity regulation

    Directory of Open Access Journals (Sweden)

    Jiajia Zhou

    2018-05-01

    Full Text Available This paper attempts to address the motion parameter skip problem associated with three-dimensional trajectory tracking of an underactuated Autonomous Underwater Vehicle (AUV using backstepping-based control, due to the unsmoothness of tracking trajectory. Through kinematics concepts, a three-dimensional dynamic velocity regulation controller is derived. This controller makes use of the surge and angular velocity errors with bio-inspired models and backstepping techniques. It overcomes the frequently occurring problem of parameter skip at inflection point existing in backstepping tracking control method and increases system robustness. Moreover, the proposed method can effectively avoid the singularity problem in backstepping control of virtual velocity error. The control system is proved to be uniformly ultimately bounded using Lyapunov stability theory. Simulation results illustrate the effectiveness and efficiency of the developed controller, which can realize accurate three-dimensional trajectory tracking for an underactuated AUV with constant external disturbances. Keywords: Dynamic velocity regulation, Bio-inspired model, Backstepping, Underactuated AUV, Three-dimensional trajectory tracking

  5. [Bone drilling simulation by three-dimensional imaging].

    Science.gov (United States)

    Suto, Y; Furuhata, K; Kojima, T; Kurokawa, T; Kobayashi, M

    1989-06-01

    The three-dimensional display technique has a wide range of medical applications. Pre-operative planning is one typical application: in orthopedic surgery, three-dimensional image processing has been used very successfully. We have employed this technique in pre-operative planning for orthopedic surgery, and have developed a simulation system for bone-drilling. Positive results were obtained by pre-operative rehearsal; when a region of interest is indicated by means of a mouse on the three-dimensional image displayed on the CRT, the corresponding region appears on the slice image which is displayed simultaneously. Consequently, the status of the bone-drilling is constantly monitored. In developing this system, we have placed emphasis on the quality of the reconstructed three-dimensional images, on fast processing, and on the easy operation of the surgical planning simulation.

  6. Effect of Scanning and Reconstruction Parameters on Three Dimensional Volume and CT Value Measurement of Pulmonary Nodules: A Phantom Study

    Directory of Open Access Journals (Sweden)

    Datong SU

    2017-08-01

    Full Text Available Background and objective The computed tomography (CT follow-up of indeterminate pulmonary nodules aiming to evaluate the change of the volume and CT value is the common strategy in clinic. The CT dose needs to considered on serious CT scans in addition to the measurement accuracy. The purpose of this study is to quantify the precision of pulmonary nodule volumetric measurement and CT value measurement with various tube currents and reconstruction algorithms in a phantom study with dual-energy CT. Methods A chest phantom containing 9 artificial spherical solid nodules with known diameter (D=2.5 mm, 5 mm, 10 mm and density (-100 HU, 60 HU and 100 HU was scanned using a 64-row detector CT canner at 120 Kilovolt & various currents (10 mA, 20 mA, 50 mA, 80 mA,100 mA, 150 mA and 350 mA. Raw data were reconstructed with filtered back projection and three levels of adaptive statistical iterative reconstruction algorithm (FBP, ASIR; 30%, 50% and 80%. Automatic volumetric measurements were performed using commercially available software. The relative volume error (RVE and the absolute attenuation error (AAE between the software measures and the reference-standard were calculated. Analyses of the variance were performed to evaluate the effect of reconstruction methods, different scan parameters, nodule size and attenuation on the RPE. Results The software substantially overestimated the very small (D=2.5 mm nodule's volume [mean RVE: (100.8%±28%] and underestimated it attenuation [mean AAE: (-756±80 HU]. The mean RVEs of nodule with diameter as 5 mm and 10 mm were small [(-0.9%±1.1% vs (0.9%±1.4%], however, the mean AAEs [(-243±26 HU vs (-129±7 HU] were large. The ANOVA analysis for repeated measurements showed that different tube current and reconstruction algorithm had no significant effect on the volumetric measurements for nodules with diameter of 5 mm and 10 mm (F=5.60, P=0.10 vs F=11.13, P=0.08, but significant effects on the measurement of CT

  7. Three-Dimensional Printing Surgical Applications.

    Science.gov (United States)

    AlAli, Ahmad B; Griffin, Michelle F; Butler, Peter E

    2015-01-01

    Three-dimensional printing, a technology used for decades in the industrial field, gains a lot of attention in the medical field for its potential benefits. With advancement of desktop printers, this technology is accessible and a lot of research is going on in the medical field. To evaluate its application in surgical field, which may include but not limited to surgical planning, surgical education, implants, and prosthesis, which are the focus of this review. Research was conducted by searching PubMed, Web of science, and other reliable sources. We included original articles and excluded articles based on animals, those more than 10 years old, and those not in English. These articles were evaluated, and relevant studies were included in this review. Three-dimensional printing shows a potential benefit in surgical application. Printed implants were used in patient in a few cases and show successful results; however, longer follow-up and more trials are needed. Surgical and medical education is believed to be more efficient with this technology than the current practice. Printed surgical instrument and surgical planning are also believed to improve with three-dimensional printing. Three-dimensional printing can be a very powerful tool in the near future, which can aid the medical field that is facing a lot of challenges and obstacles. However, despite the reported results, further research on larger samples and analytical measurements should be conducted to ensure this technology's impact on the practice.

  8. Growth and Development of Three-Dimensional Plant Form.

    Science.gov (United States)

    Whitewoods, Christopher D; Coen, Enrico

    2017-09-11

    Plants can generate a spectacular array of complex shapes, many of which exhibit elaborate curvature in three dimensions, illustrated for example by orchid flowers and pitcher-plant traps. All of these structures arise through differential growth. Recent findings provide fresh mechanistic insights into how regional cell behaviours may lead to tissue deformations, including anisotropies and curvatures, which shape growing volumes and sheets of cells. Here were review our current understanding of how genes, growth, mechanics, and evolution interact to generate diverse structures. We illustrate problems and approaches with the complex three-dimensional trap of the bladderwort, Utricularia gibba, to show how a multidisciplinary approach can be extended to new model systems to understand how diverse plant shapes can develop and evolve. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Prenatal diagnosis of Beckwith-Wiedemann syndrome by two- and three-dimensional ultrasonography

    Directory of Open Access Journals (Sweden)

    Edward Araujo Junior

    2013-12-01

    Full Text Available Beckwith-Wiedemann syndrome is a genetic syndrome characterized by macroglossia, omphalocele, fetal gigantism and neonatal hypoglycemia. The authors report a case of Beckwith-Wiedemann syndrome diagnosed in a 32-year-old primigravida in whom two-dimensional ultrasonography revealed the presence of abdominal wall cyst, macroglossia and polycystic kidneys. Three-dimensional ultrasonography in rendering mode was of great importance to confirm the previous two-dimensional ultrasonography findings.

  10. Towards three-dimensional optical metamaterials

    Science.gov (United States)

    Tanaka, Takuo; Ishikawa, Atsushi

    2017-12-01

    Metamaterials have opened up the possibility of unprecedented and fascinating concepts and applications in optics and photonics. Examples include negative refraction, perfect lenses, cloaking, perfect absorbers, and so on. Since these metamaterials are man-made materials composed of sub-wavelength structures, their development strongly depends on the advancement of micro- and nano-fabrication technologies. In particular, the realization of three-dimensional metamaterials is one of the big challenges in this research field. In this review, we describe recent progress in the fabrication technologies for three-dimensional metamaterials, as well as proposed applications.

  11. Software-triggered contrast-enhanced three-dimensional MR angiography of the intracranial arteries.

    Science.gov (United States)

    Isoda, H; Takehara, Y; Isogai, S; Takeda, H; Tanaka, T; Takahashi, M; Nozaki, A; Sun, Y

    2000-02-01

    We investigated the effectiveness of software-triggered contrast-enhanced three-dimensional (3D) MR angiography in evaluating intracranial arteries. We studied 38 patients with suspected brain lesions. Imaging was performed using a 1.5-T superconducting MR system with a commercially available head coil. To monitor signal intensity changes we used software to place a tracker volume at the basilar artery or the internal carotid artery. A 20-ml bolus of gadodiamide hydrate was administered through the antecubital vein at a rate of 2-4 ml/sec, followed by a saline flush. Three-dimensional MR angiography using a spoiled gradient-echo sequence with centric K-space ordering was triggered by the arrival of the contrast bolus in the tracker volume. Imaging times ranged from 12 to 20 sec. We used MR images to assess the effectiveness of contrast-enhanced 3D MR angiography in revealing intracranial arteries with minimal venous overlap. The software triggered imaging on the arrival of the contrast bolus in 81.6% of examinations. In 77.6% of examinations, the resulting MR angiograms revealed intracranial arteries with minimal venous overlap. Software-triggered contrast-enhanced 3D MR angiography with centric K-space ordering is a promising technique for viewing intracranial arteries.

  12. Three-dimensional imaging modalities in endodontics

    Science.gov (United States)

    Mao, Teresa

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome. PMID:25279337

  13. Three-dimensional imaging modalities in endodontics

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Teresa; Neelakantan, Prasanna [Dept. of Conservative Dentistry and Endodontics, Saveetha Dental College and Hospitals, Saveetha University, Chennai (India)

    2014-09-15

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

  14. Three-dimensional imaging modalities in endodontics

    International Nuclear Information System (INIS)

    Mao, Teresa; Neelakantan, Prasanna

    2014-01-01

    Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of peri-radicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome

  15. Bifurcation structures and transient chaos in a four-dimensional Chua model

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, Anderson, E-mail: hoffande@gmail.com; Silva, Denilson T. da; Manchein, Cesar, E-mail: cesar.manchein@udesc.br; Albuquerque, Holokx A., E-mail: holokx.albuquerque@udesc.br

    2014-01-10

    A four-dimensional four-parameter Chua model with cubic nonlinearity is studied applying numerical continuation and numerical solutions methods. Regarding numerical solution methods, its dynamics is characterized on Lyapunov and isoperiodic diagrams and regarding numerical continuation method, the bifurcation curves are obtained. Combining both methods the bifurcation structures of the model were obtained with the possibility to describe the shrimp-shaped domains and their endoskeletons. We study the effect of a parameter that controls the dimension of the system leading the model to present transient chaos with its corresponding basin of attraction being riddled.

  16. A three-dimensional field solutions of Halbach

    International Nuclear Information System (INIS)

    Chen Jizhong; Xiao Jijun; Zhang Yiming; Xu Chunyan

    2008-01-01

    A three-dimensional field solutions are presented for Halback cylinder magnet. Based on Ampere equivalent current methods, the permanent magnets are taken as distributing of current density. For getting the three-dimensional field solution of ideal polarized permanent magnets, the solution method entails the use of the vector potential and involves the closed-form integration of the free-space Green's function. The programmed field solution are ideal for performing rapid parametric studies of the dipole Halback cylinder magnets made from rare earth materials. The field solutions are verified by both an analytical two-dimensional algorithm and three-dimensional finite element software. A rapid method is presented for extensive analyzing and optimizing Halbach cylinder magnet. (authors)

  17. Fabrication of three-dimensional micro-nanofiber structures by a novel solution blow spinning device

    Directory of Open Access Journals (Sweden)

    Feng Liang

    2017-02-01

    Full Text Available The fabrication of three-dimensional scaffolds has attracted more attention in tissue engineering. The purpose of this study is to explore a new method for the fabrication of three-dimensional micro-nanofiber structures by combining solution blow spinning and rotating collector. In this study, we successfully fabricated fibers with a minimum diameter of 200 nm and a three-dimensional structure with a maximum porosity of 89.9%. At the same time, the influence of various parameters such as the solvent volatility, the shape of the collector, the feed rate of the solution and the applied gas pressure were studied. It is found that solvent volatility has large effect on the formation of the three-dimensional shape of the structure. The shape of the collector affects the porosity and fiber distribution of the three-dimensional structure. The fiber diameter and fiber uniformity can be controlled by adjusting the solution feed rate and the applied gas pressure. It is feasible to fabricate high-quality three-dimensional micro-nanofiber structure by this new method, which has great potential in tissue engineering.

  18. Three-dimensional helical (spiral) CT angiography. Visualization of vessels in the maxillofacial regions

    International Nuclear Information System (INIS)

    Hanawa, Shigeo; Sakamoto, Hidetomo; Mori, Shin-ichiro; Kagawa, Toyohiro; Seze, Ryosuke; Ishioka, Hisakazu; Tashiro, Himiko; Ogawa, Kazuhisa; Wada, Tadako

    1998-01-01

    Authors performed the contrast helical CT for tumors on the maxillofacial regions, and reconstituted these data into the three-dimensional helical (spiral) CT angiography (CTA). Furthermore the conditions of photographing and the clinical significance of CTA were discussed. The subjects were 24 cases (including 13 of malignant tumors, 4 of benign tumors, 4 of inflammation and 3 of malformations), to which the contrast helical CT was performed transvenously. The photographing condition was set in principal to 140 kV of the tube voltage, 160 (200) mA of the tube current, 3 mm of the X-ray beam width, 3 mm/sec (pitch=1) of the turn-table moving speed. The relationship between the beam width and the pitch was determined by the phantom experiments. The scanning was carried out maximally for continuous 60 sec as the scanning time of a turn/sec. Of all cases, CTA visualized three-dimensionally vessels, but it was hard in the total carotid arteries and the internal-external carotid arteries. Authors analyzed the axial and the multiplanar reconstitution (MPR) images as the two-dimensional display, and the surface rendering (SR), the volume rendering and the maximum intensity projections (MIP) as the three-dimensional display. The axial and MPR image of the facial arteries and the lingual arteries as the branched vessels from the external carotid arteries were recognized easily. By SR, it was easily to understand the anatomical relationship among vessels, gnathic bone and cervical vertebrae, and by MIP sufficiently observe the concentration dependent calcification of the vessel walls. Three-dimensional CTA is very useful to get the three-dimensional visual information about the anatomical structures of the maxillofacial regions which is necessary for oral surgeons to plan the pre-operational strategies. (K.H.)

  19. Ventricular enlargement in multiple sclerosis: a comparison of three-dimensional and linear MRI estimates

    International Nuclear Information System (INIS)

    Turner, B.; Blumhardt, L.D.; Ramli, N.; Jaspan, T.

    2001-01-01

    Atrophy of central white matter is related to irreversible clinical disability in multiple sclerosis (MS) and ventricular enlargement may be a sensitive marker of this tissue loss. Therapeutic trials in MS have provided MRI data for investigation of cerebral atrophy in MS. These studies use almost exclusively two-dimensional (2-D) images, which may be limited in the assessment of three-dimensional (3-D) structures. We used 3-D MRI data to estimate ventricular volumes in 40 patients with MS and 10 healthy controls, to look at associations with clinical disability and the stage of the disease. We then compared simple linear measures of ventricular size from conventional 2-D images, with 3-D volume estimates to establish the best available linear indices of ventricular volume. Mean ventricular volumes were increased in the patients and significantly larger in the more disabled patients. The estimated volume of the third ventricle obtained from 3-D MRI showed the strongest association with the clinical stage of the disease, duration of symptoms and levels of disability. Finally, we confirmed that in patients with MS accurate data on ventricular size can be obtained from 2-D images by two simple and convenient linear measures, the width of the third ventricle and of the anterior horn of the lateral ventricle. (orig.)

  20. Three Dimensional Dirac Semimetals

    Science.gov (United States)

    Zaheer, Saad

    2014-03-01

    Dirac points on the Fermi surface of two dimensional graphene are responsible for its unique electronic behavior. One can ask whether any three dimensional materials support similar pseudorelativistic physics in their bulk electronic spectra. This possibility has been investigated theoretically and is now supported by two successful experimental demonstrations reported during the last year. In this talk, I will summarize the various ways in which Dirac semimetals can be realized in three dimensions with primary focus on a specific theory developed on the basis of representations of crystal spacegroups. A three dimensional Dirac (Weyl) semimetal can appear in the presence (absence) of inversion symmetry by tuning parameters to the phase boundary separating a bulk insulating and a topological insulating phase. More generally, we find that specific rules governing crystal symmetry representations of electrons with spin lead to robust Dirac points at high symmetry points in the Brillouin zone. Combining these rules with microscopic considerations identifies six candidate Dirac semimetals. Another method towards engineering Dirac semimetals involves combining crystal symmetry and band inversion. Several candidate materials have been proposed utilizing this mechanism and one of the candidates has been successfully demonstrated as a Dirac semimetal in two independent experiments. Work carried out in collaboration with: Julia A. Steinberg, Steve M. Young, J.C.Y. Teo, C.L. Kane, E.J. Mele and Andrew M. Rappe.

  1. Three-dimensional instability of standing waves

    Science.gov (United States)

    Zhu, Qiang; Liu, Yuming; Yue, Dick K. P.

    2003-12-01

    We investigate the three-dimensional instability of finite-amplitude standing surface waves under the influence of gravity. The analysis employs the transition matrix (TM) approach and uses a new high-order spectral element (HOSE) method for computation of the nonlinear wave dynamics. HOSE is an extension of the original high-order spectral method (HOS) wherein nonlinear wave wave and wave body interactions are retained up to high order in wave steepness. Instead of global basis functions in HOS, however, HOSE employs spectral elements to allow for complex free-surface geometries and surface-piercing bodies. Exponential convergence of HOS with respect to the total number of spectral modes (for a fixed number of elements) and interaction order is retained in HOSE. In this study, we use TM-HOSE to obtain the stability of general three-dimensional perturbations (on a two-dimensional surface) on two classes of standing waves: plane standing waves in a rectangular tank; and radial/azimuthal standing waves in a circular basin. For plane standing waves, we confirm the known result of two-dimensional side-bandlike instability. In addition, we find a novel three-dimensional instability for base flow of any amplitude. The dominant component of the unstable disturbance is an oblique (standing) wave oriented at an arbitrary angle whose frequency is close to the (nonlinear) frequency of the original standing wave. This finding is confirmed by direct long-time simulations using HOSE which show that the nonlinear evolution leads to classical Fermi Pasta Ulam recurrence. For the circular basin, we find that, beyond a threshold wave steepness, a standing wave (of nonlinear frequency Omega) is unstable to three-dimensional perturbations. The unstable perturbation contains two dominant (standing-wave) components, the sum of whose frequencies is close to 2Omega. From the cases we consider, the critical wave steepness is found to generally decrease/increase with increasing radial

  2. Extracting Metrics for Three-dimensional Root Systems: Volume and Surface Analysis from In-soil X-ray Computed Tomography Data.

    Science.gov (United States)

    Suresh, Niraj; Stephens, Sean A; Adams, Lexor; Beck, Anthon N; McKinney, Adriana L; Varga, Tamas

    2016-04-26

    Plant roots play a critical role in plant-soil-microbe interactions that occur in the rhizosphere, as well as processes with important implications to climate change and crop management. Quantitative size information on roots in their native environment is invaluable for studying root growth and environmental processes involving plants. X-ray computed tomography (XCT) has been demonstrated to be an effective tool for in situ root scanning and analysis. We aimed to develop a costless and efficient tool that approximates the surface and volume of the root regardless of its shape from three-dimensional (3D) tomography data. The root structure of a Prairie dropseed (Sporobolus heterolepis) specimen was imaged using XCT. The root was reconstructed, and the primary root structure was extracted from the data using a combination of licensed and open-source software. An isosurface polygonal mesh was then created for ease of analysis. We have developed the standalone application imeshJ, generated in MATLAB(1), to calculate root volume and surface area from the mesh. The outputs of imeshJ are surface area (in mm(2)) and the volume (in mm(3)). The process, utilizing a unique combination of tools from imaging to quantitative root analysis, is described. A combination of XCT and open-source software proved to be a powerful combination to noninvasively image plant root samples, segment root data, and extract quantitative information from the 3D data. This methodology of processing 3D data should be applicable to other material/sample systems where there is connectivity between components of similar X-ray attenuation and difficulties arise with segmentation.

  3. Equatorial spread F studies using SAMI3 with two-dimensional and three-dimensional electrostatics

    Directory of Open Access Journals (Sweden)

    H. C. Aveiro

    2013-12-01

    Full Text Available This letter presents a study of equatorial F region irregularities using the NRL SAMI3/ESF model, comparing results using a two-dimensional (2-D and a three-dimensional (3-D electrostatic potential solution. For the 3-D potential solution, two cases are considered for parallel plasma transport: (1 transport based on the parallel ambipolar field, and (2 transport based on the parallel electric field. The results show that the growth rate of the generalized Rayleigh–Taylor instability is not affected by the choice of the potential solution. However, differences are observed in the structures of the irregularities between the 2-D and 3-D solutions. Additionally, the plasma velocity along the geomagnetic field computed using the full 3-D solution shows complex structures that are not captured by the simplified model. This points out that only the full 3-D model is able to fully capture the complex physics of the equatorial F region.

  4. Semi-implicit method for three-dimensional compressible MHD simulation

    International Nuclear Information System (INIS)

    Harned, D.S.; Kerner, W.

    1984-03-01

    A semi-implicit method for solving the full compressible MHD equations in three dimensions is presented. The method is unconditionally stable with respect to the fast compressional modes. The time step is instead limited by the slower shear Alfven motion. The computing time required for one time step is essentially the same as for explicit methods. Linear stability limits are derived and verified by three-dimensional tests on linear waves in slab geometry. (orig.)

  5. Two- to three-dimensional crossover in a dense electron liquid in silicon

    Science.gov (United States)

    Matmon, Guy; Ginossar, Eran; Villis, Byron J.; Kölker, Alex; Lim, Tingbin; Solanki, Hari; Schofield, Steven R.; Curson, Neil J.; Li, Juerong; Murdin, Ben N.; Fisher, Andrew J.; Aeppli, Gabriel

    2018-04-01

    Doping of silicon via phosphine exposures alternating with molecular beam epitaxy overgrowth is a path to Si:P substrates for conventional microelectronics and quantum information technologies. The technique also provides a well-controlled material for systematic studies of two-dimensional lattices with a half-filled band. We show here that for a dense (ns=2.8 ×1014 cm-2) disordered two-dimensional array of P atoms, the full field magnitude and angle-dependent magnetotransport is remarkably well described by classic weak localization theory with no corrections due to interaction. The two- to three-dimensional crossover seen upon warming can also be interpreted using scaling concepts developed for anistropic three-dimensional materials, which work remarkably except when the applied fields are nearly parallel to the conducting planes.

  6. Transient response in granular quasi-two-dimensional bounded heap flow.

    Science.gov (United States)

    Xiao, Hongyi; Ottino, Julio M; Lueptow, Richard M; Umbanhowar, Paul B

    2017-10-01

    We study the transition between steady flows of noncohesive granular materials in quasi-two-dimensional bounded heaps by suddenly changing the feed rate. In both experiments and simulations, the primary feature of the transition is a wedge of flowing particles that propagates downstream over the rising free surface with a wedge front velocity inversely proportional to the square root of time. An additional longer duration transient process continues after the wedge front reaches the downstream wall. The entire transition is well modeled as a moving boundary problem with a diffusionlike equation derived from local mass balance and a local relation between the flux and the surface slope.

  7. Pore-scale simulation of fluid flow and solute dispersion in three-dimensional porous media

    KAUST Repository

    Icardi, Matteo

    2014-07-31

    In the present work fluid flow and solute transport through porous media are described by solving the governing equations at the pore scale with finite-volume discretization. Instead of solving the simplified Stokes equation (very often employed in this context) the full Navier-Stokes equation is used here. The realistic three-dimensional porous medium is created in this work by packing together, with standard ballistic physics, irregular and polydisperse objects. Emphasis is placed on numerical issues related to mesh generation and spatial discretization, which play an important role in determining the final accuracy of the finite-volume scheme and are often overlooked. The simulations performed are then analyzed in terms of velocity distributions and dispersion rates in a wider range of operating conditions, when compared with other works carried out by solving the Stokes equation. Results show that dispersion within the analyzed porous medium is adequately described by classical power laws obtained by analytic homogenization. Eventually the validity of Fickian diffusion to treat dispersion in porous media is also assessed. © 2014 American Physical Society.

  8. Three-dimensional spatial imaging in multiphoton ionization rate measurements

    International Nuclear Information System (INIS)

    Bredy, Richard; Camp, Howard A.; Nguyen, Hai; Awata, Takaaki; Shan Bing; Chang Zhenghu; DePaola, B.D.

    2004-01-01

    An experiment is described in which an apparatus is used to demonstrate the feasibility of measuring multiphoton photoionization rates in the interaction of short pulsed lasers with atoms or molecules. With this methodology, the ionization rate is measured as a function of the spatial position in the beam-waist region of the laser through the direct three-dimensional spatial imaging of the ionization events. Thus, if the spatial dependence of the laser beam intensity were known, a series of experiments could yield the intensity dependence of multiphoton ionization without the assumptions or errors that are generally inherent in the integration over one or more dimensions in the laser focal volume

  9. Transient and 2-Dimensional Shear-Wave Elastography Provide Comparable Assessment of Alcoholic Liver Fibrosis and Cirrhosis

    DEFF Research Database (Denmark)

    Thiele, Maja; Detlefsen, Sönke; Møller, Linda Maria Sevelsted

    2016-01-01

    clinics (in Southern Denmark). The second, lower-risk group, was recruited from municipal alcohol rehabilitation centers and the Danish national public health portal. All subjects underwent same-day transient elastography (FibroScan), 2-dimensional shear wave elastography (Supersonic Aixplorer), and liver...

  10. Multiparallel Three-Dimensional Optical Microscopy

    Science.gov (United States)

    Nguyen, Lam K.; Price, Jeffrey H.; Kellner, Albert L.; Bravo-Zanoquera, Miguel

    2010-01-01

    Multiparallel three-dimensional optical microscopy is a method of forming an approximate three-dimensional image of a microscope sample as a collection of images from different depths through the sample. The imaging apparatus includes a single microscope plus an assembly of beam splitters and mirrors that divide the output of the microscope into multiple channels. An imaging array of photodetectors in each channel is located at a different distance along the optical path from the microscope, corresponding to a focal plane at a different depth within the sample. The optical path leading to each photodetector array also includes lenses to compensate for the variation of magnification with distance so that the images ultimately formed on all the photodetector arrays are of the same magnification. The use of optical components common to multiple channels in a simple geometry makes it possible to obtain high light-transmission efficiency with an optically and mechanically simple assembly. In addition, because images can be read out simultaneously from all the photodetector arrays, the apparatus can support three-dimensional imaging at a high scanning rate.

  11. Backlund transformations and three-dimensional lattice equations

    NARCIS (Netherlands)

    Nijhoff, F.W.; Capel, H.W.; Wiersma, G.L.; Quispel, G.R.W.

    1984-01-01

    A (nonlocal) linear integral equation is studied, which allows for Bäcklund transformations in the measure. The compatibility of three of these transformations leads to an integrable nonlinear three-dimensional lattice equation. In appropriate continuum limits the two-dimensional Toda-lattice

  12. Athermal mechanisms of size-dependent crystal flow gleaned from three-dimensional discrete dislocation simulations

    International Nuclear Information System (INIS)

    Rao, S.I.; Dimiduk, D.M.; Parthasarathy, T.A.; Uchic, M.D.; Tang, M.; Woodward, C.

    2008-01-01

    Recent experimental studies have revealed that micrometer-scale face-centered cubic (fcc) crystals show strong strengthening effects, even at high initial dislocation densities. We use large-scale three-dimensional discrete dislocation simulations (DDS) to explicitly model the deformation behavior of fcc Ni microcrystals in the size range of 0.5-20 μm. This study shows that two size-sensitive athermal hardening processes, beyond forest hardening, are sufficient to develop the dimensional scaling of the flow stress, stochastic stress variation, flow intermittency and high initial strain-hardening rates, similar to experimental observations for various materials. One mechanism, source-truncation hardening, is especially potent in micrometer-scale volumes. A second mechanism, termed exhaustion hardening, results from a breakdown of the mean-field conditions for forest hardening in small volumes, thus biasing the statistics of ordinary dislocation processes

  13. Fast Transient And Spatially Non-Homogenous Accident Analysis Of Two-Dimensional Cylindrical Nuclear Reactor

    International Nuclear Information System (INIS)

    Yulianti, Yanti; Su'ud, Zaki; Waris, Abdul; Khotimah, S. N.; Shafii, M. Ali

    2010-01-01

    The research about fast transient and spatially non-homogenous nuclear reactor accident analysis of two-dimensional nuclear reactor has been done. This research is about prediction of reactor behavior is during accident. In the present study, space-time diffusion equation is solved by using direct methods which consider spatial factor in detail during nuclear reactor accident simulation. Set of equations that obtained from full implicit finite-difference discretization method is solved by using iterative methods ADI (Alternating Direct Implicit). The indication of accident is decreasing macroscopic absorption cross-section that results large external reactivity. The power reactor has a peak value before reactor has new balance condition. Changing of temperature reactor produce a negative Doppler feedback reactivity. The reactivity will reduce excess positive reactivity. Temperature reactor during accident is still in below fuel melting point which is in secure condition.

  14. Arching in three-dimensional clogging

    Science.gov (United States)

    Török, János; Lévay, Sára; Szabó, Balázs; Somfai, Ellák; Wegner, Sandra; Stannarius, Ralf; Börzsönyi, Tamás

    2017-06-01

    Arching in dry granular material is a long established concept, however it remains still an open question how three-dimensional orifices clog. We investigate by means of numerical simulations and experimental data how the outflow creates a blocked configuration of particles. We define the concave surface of the clogged dome by two independent methods (geometric and density based). The average shape of the cupola for spheres is almost a hemisphere but individual samples have large holes in the structure indicating a blocked state composed of two-dimensional force chains rather than three-dimensional objects. The force chain structure justifies this assumption. For long particles the clogged configurations display large variations, and in certain cases the empty region reaches a height of 5 hole diameters. These structures involve vertical walls consisting of horizontally placed stable stacking of particles.

  15. Micro injection moulding process optimization of an ultra-small POM three-dimensional component

    DEFF Research Database (Denmark)

    Baruffi, Federico; Calaon, Matteo; Tosello, Guido

    Replication-based manufacturing processes are a cost effective method for producing complex and net-shaped components [1]. Micro injection moulding has a prominent place among them for its capability of accurately and precisely produce micro plastic parts in large production scale [2], [3......]. In this study, the optimization of the micro injection moulding process of an ultra-small (volume: 0.07 mm3; mass: 0.1 mg) three-dimensional Polyoxymethylene (POM) micro component for medical applications (see Figure 1) is presented. Preliminary experiments highlighted the need for venting channels in order...... with respect to design specifications, the flash areal size was utilized as quality indicator. A design of the experiments approach was carried out in order to study the effects of melt temperature, mould temperature, holding pressure and injection speed. For this task, a two-level full factorial design...

  16. Implementation of three dimensional conformal radiation therapy: prospects, opportunities, and challenges

    International Nuclear Information System (INIS)

    Vijayakumar, Srinivasan; Chen, George T.Y.

    1995-01-01

    Purpose: To briefly review scientific rationale of 3D conformal radiation therapy (3DCRT) and discuss the prospects, opportunities, and challenges in the implementation of 3DCRT. Some of these ideas were discussed during a workshop on 'Implementation of Three-Dimensional Conformal Radiation Therapy' in April 1994 at Bethesda, MD, and others have been discussed elsewhere in the literature. Methods and Materials: Local-regional control of cancer is an important component in the overall treatment strategy in any patient with cancer. It has been shown that failure to achieve local-regional control can lead to (a) an increase in chances of distant metastases, and (b) a decrease in the survival. In many disease sites, the doses delivered currently are inadequate to achieve satisfactory local tumor control rates; this is because in many sites, only limited doses of radiotherapy can be delivered due to the proximity of cancer to radiosensitive normal tissues. By conforming the radiotherapy beams to the tumor, doses to the tumors can be enhanced and doses to the normal tissues can be reduced. With the advances in 3DCRT, such conformation is possible now and is the rationale for using 3DCRT. However, a number of questions do remain that are not limited to the following: (a) What are the implications in terms of target volume definitions when implementing 3DCRT? (b) Are there some sites where research efforts can be focused to document the efficacy and cost effectiveness of 3DCRT? (c) How do we implement day-to-day 3DCRT treatment efficiently? (d) How do we transfer the technology from the university centers to the community without compromising quality? (e) What are all the quality assurance/quality improvement questions that need to be addressed and how do we ascertain quality assurance of 3DCRT? (f) Have we looked at cost-benefit ratios and quality of life (QOL) issues closely? Results: There is a need for defining multiple target volumes: gross tumor volume, clinical

  17. Three-dimensional reconstruction of the biliary tract using spiral computed tomography. Three-dimensional cholangiography

    International Nuclear Information System (INIS)

    Gon, Masanori; Ogura, Norihiro; Uetsuji, Shouji; Ueyama, Yasuo

    1995-01-01

    In this study, 310 patients with benign biliary diseases, 20 with gallbladder cancer, and 8 with biliary tract carcinoma underwent spiral CT (SCT) scanning at cholangiography. Depiction rate of the shape of the conjunction site of the gallbladder and biliary tract was 27.5% by conventional intravenous cholangiography (DIC), 92.5% by ERC, and 90.0% by DIC-SCT. Abnormal cystic duct course was admitted in 14.1%. Multiplanar reconstruction by DIC-SCT enabled identification of the common bile duct and intrahepatic bile duct stone. Three-dimensional reconstruction of DIC-SCT was effective in evaluating obstruction of the anastomosis or passing condition of after hepatico-jejunostomy. Two-dimensional SCT images through PTCD tube enabled degree of hepatic invasion in bile duct cancer, and three-dimensional images were useful in grasping the morphology of the bile duct branches near the obstruction site. DIC-SCT is therefore considered a useful procedure as non-invasive examination of bile duct lesions. (S.Y.)

  18. Factors Affecting Canagliflozin-Induced Transient Urine Volume Increase in Patients with Type 2 Diabetes Mellitus.

    Science.gov (United States)

    Tanaka, Hiroyuki; Takano, Kazuhiko; Iijima, Hiroaki; Kubo, Hajime; Maruyama, Nobuko; Hashimoto, Toshio; Arakawa, Kenji; Togo, Masanori; Inagaki, Nobuya; Kaku, Kohei

    2017-02-01

    Sodium glucose co-transporter 2 (SGLT2) inhibitors exhibit diuretic activity, which is a possible mechanism underlying the cardiovascular benefit of these inhibitors. However, the osmotic diuresis-induced increase in urine volume, and the risk of dehydration have been of concern with SGLT2 inhibitor treatment. This study aimed to investigate the mechanism underlying SGLT2 inhibitor canagliflozin-induced diuresis in Japanese type 2 diabetes mellitus (T2DM) patients. Thirteen T2DM patients received a daily oral dose of 100 mg canagliflozin before breakfast for 6 days. Blood and urine samples were collected at predetermined time points. The primary endpoint was evaluation of correlations between changes from baseline in urine volume and factors that are known to affect urine volume and between actual urine volume and these factors. Canagliflozin transiently increased urine volume and urinary sodium excretion on Day 1 with a return to baseline levels thereafter. Canagliflozin administration increased urinary glucose excretion, which was sustained during repeated-dose administration. Plasma atrial natriuretic peptide (ANP) and N-terminal pro-b-type natriuretic peptide (NT-proBNP) levels decreased, while plasma renin activity increased. On Day 1 of treatment, changes in sodium and potassium excretion were closely correlated with changes in urine output. A post hoc multiple regression analysis showed changes in sodium excretion and water intake as factors that affected urine volume change at Day 1. Furthermore, relative to that at baseline, canagliflozin decreased blood glucose throughout the day and increased plasma total GLP-1 after breakfast. Canagliflozin induced transient sodium excretion and did not induce water intake at Day 1; hence, natriuresis rather than glucose-induced osmotic diuresis may be a major factor involved in the canagliflozin-induced transient increase in urine output. In addition, canagliflozin decreased plasma ANP and NT-proBNP levels and

  19. Ultrasound measurements of testicular volume: Comparing the three ...

    African Journals Online (AJOL)

    T.U. Mbaeri

    The ultrasound measurements of the testicular volume were calculated using the following three formulas: (a) length ... ticular growth, development and function. Studies in ... of the components of a minimum full evaluation of male infertility is palpation of ... opted for orchidectomy after counseling in our center. Subjects and ...

  20. Optimization of three-dimensional micropost microcavities for cavity quantum electrodynamics

    International Nuclear Information System (INIS)

    Vuckovic, Jelena; Pelton, Matthew; Scherer, Axel; Yamamoto, Yoshihisa

    2002-01-01

    This paper presents a detailed analysis, based on the first-principles finite-difference time-domain method, of the resonant frequency, quality factor (Q), mode volume (V), and radiation pattern of the fundamental (HE 11 ) mode in a three-dimensional distributed-Bragg-reflector (DBR) micropost microcavity. By treating this structure as a one-dimensional cylindrical photonic crystal containing a single defect, we are able to push the limits of Q/V beyond those achievable by standard micropost designs, based on the simple rules established for planar DBR microcavities. We show that some of the rules that work well for designing large-diameter microposts (e.g., high-refractive-index contrast) fail to provide high-quality cavities with small diameters. By tuning the thicknesses of mirror layers and the spacer, the number of mirror pairs, the refractive indices of high- and low-refractive index regions, and the cavity diameter, we are able to achieve Q as high as 10 4 , together with a mode volume of 1.6 cubic wavelengths of light in the high-refractive-index material. The combination of high Q and small V makes these structures promising candidates for the observation of such cavity-quantum-electrodynamics phenomena as strong coupling between a quantum dot and the cavity field, and single-quantum-dot lasing

  1. Three-dimensional appearance of the lips muscles with three-dimensional isotropic MRI: in vivo study

    Energy Technology Data Exchange (ETDEWEB)

    Olszewski, Raphael; Reychler, H. [Universite Catholique de Louvain, Department of Oral and Maxillofacial Surgery, Cliniques Universitaires Saint Luc, Brussels (Belgium); Liu, Y.; Xu, T.M. [Peking University School and Hospital of Stomatology, Department of Orthodontics, Beijing (China); Duprez, T. [Universite Catholique de Louvain, Department of Radiology, Cliniques Universitaires Saint Luc, Brussels (Belgium)

    2009-06-15

    Our knowledge of facial muscles is based primarily on atlases and cadaveric studies. This study describes a non-invasive in vivo method (3D MRI) for segmenting and reconstructing facial muscles in a three-dimensional fashion. Three-dimensional (3D), T1-weighted, 3 Tesla, isotropic MRI was applied to a subject. One observer performed semi-automatic segmentation using the Editor module from the 3D Slicer software (Harvard Medical School, Boston, MA, USA), version 3.2. We were able to successfully outline and three-dimensionally reconstruct the following facial muscles: pars labialis orbicularis oris, m. levatro labii superioris alaeque nasi, m. levator labii superioris, m. zygomaticus major and minor, m. depressor anguli oris, m. depressor labii inferioris, m. mentalis, m. buccinator, and m. orbicularis oculi. 3D reconstruction of the lip muscles should be taken into consideration in order to improve the accuracy and individualization of existing 3D facial soft tissue models. More studies are needed to further develop efficient methods for segmentation in this field. (orig.)

  2. Three-dimensional appearance of the lips muscles with three-dimensional isotropic MRI: in vivo study.

    Science.gov (United States)

    Olszewski, Raphael; Liu, Y; Duprez, T; Xu, T M; Reychler, H

    2009-06-01

    Our knowledge of facial muscles is based primarily on atlases and cadaveric studies. This study describes a non-invasive in vivo method (3D MRI) for segmenting and reconstructing facial muscles in a three-dimensional fashion. Three-dimensional (3D), T1-weighted, 3 Tesla, isotropic MRI was applied to a subject. One observer performed semi-automatic segmentation using the Editor module from the 3D Slicer software (Harvard Medical School, Boston, MA, USA), version 3.2. We were able to successfully outline and three-dimensionally reconstruct the following facial muscles: pars labialis orbicularis oris, m. levatro labii superioris alaeque nasi, m. levator labii superioris, m. zygomaticus major and minor, m. depressor anguli oris, m. depressor labii inferioris, m. mentalis, m. buccinator, and m. orbicularis oculi. 3D reconstruction of the lip muscles should be taken into consideration in order to improve the accuracy and individualization of existing 3D facial soft tissue models. More studies are needed to further develop efficient methods for segmentation in this field.

  3. MO-B-BRB-00: Three Dimensional Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  4. Development of a Reduced-Order Three-Dimensional Flow Model for Thermal Mixing and Stratification Simulation during Reactor Transients

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Rui

    2017-09-03

    Mixing, thermal-stratification, and mass transport phenomena in large pools or enclosures play major roles for the safety of reactor systems. Depending on the fidelity requirement and computational resources, various modeling methods, from the 0-D perfect mixing model to 3-D Computational Fluid Dynamics (CFD) models, are available. Each is associated with its own advantages and shortcomings. It is very desirable to develop an advanced and efficient thermal mixing and stratification modeling capability embedded in a modern system analysis code to improve the accuracy of reactor safety analyses and to reduce modeling uncertainties. An advanced system analysis tool, SAM, is being developed at Argonne National Laboratory for advanced non-LWR reactor safety analysis. While SAM is being developed as a system-level modeling and simulation tool, a reduced-order three-dimensional module is under development to model the multi-dimensional flow and thermal mixing and stratification in large enclosures of reactor systems. This paper provides an overview of the three-dimensional finite element flow model in SAM, including the governing equations, stabilization scheme, and solution methods. Additionally, several verification and validation tests are presented, including lid-driven cavity flow, natural convection inside a cavity, laminar flow in a channel of parallel plates. Based on the comparisons with the analytical solutions and experimental results, it is demonstrated that the developed 3-D fluid model can perform very well for a wide range of flow problems.

  5. Three-Dimensional Messages for Interstellar Communication

    Science.gov (United States)

    Vakoch, Douglas A.

    One of the challenges facing independently evolved civilizations separated by interstellar distances is to communicate information unique to one civilization. One commonly proposed solution is to begin with two-dimensional pictorial representations of mathematical concepts and physical objects, in the hope that this will provide a foundation for overcoming linguistic barriers. However, significant aspects of such representations are highly conventional, and may not be readily intelligible to a civilization with different conventions. The process of teaching conventions of representation may be facilitated by the use of three-dimensional representations redundantly encoded in multiple formats (e.g., as both vectors and as rasters). After having illustrated specific conventions for representing mathematical objects in a three-dimensional space, this method can be used to describe a physical environment shared by transmitter and receiver: a three-dimensional space defined by the transmitter--receiver axis, and containing stars within that space. This method can be extended to show three-dimensional representations varying over time. Having clarified conventions for representing objects potentially familiar to both sender and receiver, novel objects can subsequently be depicted. This is illustrated through sequences showing interactions between human beings, which provide information about human behavior and personality. Extensions of this method may allow the communication of such culture-specific features as aesthetic judgments and religious beliefs. Limitations of this approach will be noted, with specific reference to ETI who are not primarily visual.

  6. Development Report on the Idaho National Laboratory Sitewide Three-Dimensional Aquifer Model

    Energy Technology Data Exchange (ETDEWEB)

    Thomas R. Wood; Catherine M. Helm-Clark; Hai Huang; Swen Magnuson; Travis McLing; Brennon Orr; Michael J. Rohe; Mitchell A. Plummer; Robert Podgorney; Erik Whitmore; Michael S. Roddy

    2007-09-01

    A sub-regional scale, three-dimensional flow model of the Snake River Plain Aquifer was developed to support remediation decisions for Waste Area Group 10, Operable Unit 10 08 at the Idaho National Laboratory (INL) Site. This model has been calibrated primarily to water levels and secondarily to groundwater velocities interpreted from stable isotope disequilibrium studies and the movement of anthropogenic contaminants in the aquifer from facilities at the INL. The three-dimensional flow model described in this report is one step in the process of constructing a fully three-dimensional groundwater flow and contaminant transport model as prescribed in the Idaho National Engineering and Environmental Laboratory Operable Unit 10-08 Sitewide Groundwater Model Work Plan. An updated three-dimensional hydrogeologic conceptual model is presented along with the geologic basis for the conceptual model. Sediment-dominated three-dimensional volumes were used to represent the geology and constrain groundwater flow as part of the conceptual model. Hydrological, geochemical, and geological data were summarized and evaluated to infer aquifer behavior. A primary observation from development and evaluation of the conceptual model was that relative to flow on a regional scale, the aquifer can be treated with steady-state conditions. Boundary conditions developed for the three-dimensional flow model are presented along with inverse simulations that estimate parameterization of hydraulic conductivity. Inverse simulations were performed using the pilot-point method to estimate permeability distributions. Thermal modeling at the regional aquifer scale and at the sub-regional scale using the inverted permeabilities is presented to corroborate the results of the flow model. The results from the flow model show good agreement with simulated and observed water levels almost always within 1 meter. Simulated velocities show generally good agreement with some discrepancies in an interpreted low

  7. Active region dimensionality and quantum efficiencies of InGaN LEDs from temperature dependent photoluminescence transients

    Science.gov (United States)

    Can, Nuri; Okur, Serdal; Monavarian, Morteza; Zhang, Fan; Avrutin, Vitaliy; Morkoç, Hadis; Teke, Ali; Özgür, Ümit

    2015-03-01

    Temperature dependent recombination dynamics in c-plane InGaN light emitting diodes (LEDs) with different well thicknesses, 1.5, 2, and 3 nm, were investigated to determine the active region dimensionality and its effect on the internal quantum efficiencies. It was confirmed for all LEDs that the photoluminescence (PL) transients are governed by radiative recombination at low temperatures while nonradiative recombination dominates at room temperature. At photoexcited carrier densities of 3 - 4.5 x 1016 cm-3 , the room-temperature Shockley-Read-Hall (A) and the bimolecular (B) recombination coefficients (A, B) were deduced to be (9.2x107 s-1, 8.8x10-10 cm3s-1), (8.5x107 s-1, 6.6x10-10 cm3s-1), and (6.5x107 s-1, 1.4x10-10 cm3s-1) for the six period 1.5, 2, and 3 nm well-width LEDs, respectively. From the temperature dependence of the radiative lifetimes, τrad α Tn/2, the dimensionality n of the active region was found to decrease consistently with decreasing well width. The 3 nm wide wells exhibited ~T1.5 dependence, suggesting a three-dimensional nature, whereas the 1.5 nm wells were confirmed to be two-dimensional (~T1) and the 2 nm wells close to being two-dimensional. We demonstrate that a combination of temperature dependent PL and time-resolved PL techniques can be used to evaluate the dimensionality as well as the quantum efficiencies of the LED active regions for a better understanding of the relationship between active-region design and the efficiency limiting processes in InGaN LEDs.

  8. Real-time three-dimensional ultrasound-assisted axillary plexus block defines soft tissue planes.

    Science.gov (United States)

    Clendenen, Steven R; Riutort, Kevin; Ladlie, Beth L; Robards, Christopher; Franco, Carlo D; Greengrass, Roy A

    2009-04-01

    Two-dimensional (2D) ultrasound is commonly used for regional block of the axillary brachial plexus. In this technical case report, we described a real-time three-dimensional (3D) ultrasound-guided axillary block. The difference between 2D and 3D ultrasound is similar to the difference between plain radiograph and computer tomography. Unlike 2D ultrasound that captures a planar image, 3D ultrasound technology acquires a 3D volume of information that enables multiple planes of view by manipulating the image without movement of the ultrasound probe. Observation of the brachial plexus in cross-section demonstrated distinct linear hyperechoic tissue structures (loose connective tissue) that initially inhibited the flow of the local anesthesia. After completion of the injection, we were able to visualize the influence of arterial pulsation on the spread of the local anesthesia. Possible advantages of this novel technology over current 2D methods are wider image volume and the capability to manipulate the planes of the image without moving the probe.

  9. Three-dimensional reconstruction and volumetry of intracranial haemorrhage and its mass effect

    International Nuclear Information System (INIS)

    Strik, H.M.; Baehr, M.; Borchert, H.; Fels, C.; Knauth, M.; Rienhoff, O.; Verhey, J.F.

    2005-01-01

    Intracerebral haemorrhage still causes considerable disability and mortality. The studies on conservative and operative management are inconclusive, probably due to inexact volumetry of the haemorrhage. We investigated whether three-dimensional (3-D), voxel-based volumetry of the haemorrhage and its mass effect is feasible with routine computed tomography (CT) scans. The volumes of the haemorrhage, ventricles, midline shift, the intracranial volume and ventricular compression in CT scans of 12 patients with basal ganglia haemorrhage were determined with the 3-D slicer software. Indices of haemorrhage and intracranial or ventricular volume were calculated and correlated with the clinical data. The intended measures could be determined with an acceptable intra-individual variability. The 3-D volumetric data tended to correlate better with the clinical course than the conventionally assessed distance of midline shift and volume of haemorrhage. 3-D volumetry of intracranial haemorrhage and its mass effect is feasible with routine CT examination. Prospective studies should assess its value for clinical studies on intracranial space-occupying diseases. (orig.)

  10. [Differential diagnosis of papillary carcinomas of the thyroid, using image analysis and three dimensional reconstruction from serial sections].

    Science.gov (United States)

    Holschbach, A; Kriete, A; Schäffer, R

    1990-01-01

    Papillae with fibrovascular cores are characteristic of papillary carcinoma of the thyroid. Papillae may be found in diffuse hyperplasia, nodular hyperplasia, Hashimoto's disease and follicular adenoma. Tissues from ten benign hyperplasias and ten papillary carcinomas were reconstructed from serial sections with three dimensional reconstruction programs. Significant qualitative and quantitative differences were found between the hyperplasia and the carcinoma. The principal differences between papillae of papillary carcinoma and hyperplasia were more clearly seen in the three dimensional reconstruction, than by means of morphometric methods. Certain criteria, e.g. the volume of papillae, were useful only with regard to the third dimension. Nevertheless, three dimensional reconstruction of biological tissue is a time consuming procedure which is not yet suitable for routine examination.

  11. Three-dimensional microstructural effects on plane strain ductile crack growth

    DEFF Research Database (Denmark)

    Tvergaard, Viggo; Needleman, Alan

    2006-01-01

    Ductile crack growth under mode 1, plane strain, small scale yielding conditions is analyzed. Overall plane strain loading is prescribed, but a full 3D analysis is carried out to model three dimensional microstructural effects. An elastic-viscoplastic constitutive relation for a porous plastic...

  12. Three-dimensional topological insulators and bosonization

    Energy Technology Data Exchange (ETDEWEB)

    Cappelli, Andrea [INFN, Sezione di Firenze,Via G. Sansone 1, 50019 Sesto Fiorentino - Firenze (Italy); Randellini, Enrico [INFN, Sezione di Firenze,Via G. Sansone 1, 50019 Sesto Fiorentino - Firenze (Italy); Dipartimento di Fisica e Astronomia, Università di Firenze,Via G. Sansone 1, 50019 Sesto Fiorentino - Firenze (Italy); Sisti, Jacopo [Scuola Internazionale Superiore di Studi Avanzati (SISSA),Via Bonomea 265, 34136 Trieste (Italy)

    2017-05-25

    Massless excitations at the surface of three-dimensional time-reversal invariant topological insulators possess both fermionic and bosonic descriptions, originating from band theory and hydrodynamic BF theory, respectively. We analyze the corresponding field theories of the Dirac fermion and compactified boson and compute their partition functions on the three-dimensional torus geometry. We then find some non-dynamic exact properties of bosonization in (2+1) dimensions, regarding fermion parity and spin sectors. Using these results, we extend the Fu-Kane-Mele stability argument to fractional topological insulators in three dimensions.

  13. Volumetric three-dimensional display system with rasterization hardware

    Science.gov (United States)

    Favalora, Gregg E.; Dorval, Rick K.; Hall, Deirdre M.; Giovinco, Michael; Napoli, Joshua

    2001-06-01

    An 8-color multiplanar volumetric display is being developed by Actuality Systems, Inc. It will be capable of utilizing an image volume greater than 90 million voxels, which we believe is the greatest utilizable voxel set of any volumetric display constructed to date. The display is designed to be used for molecular visualization, mechanical CAD, e-commerce, entertainment, and medical imaging. As such, it contains a new graphics processing architecture, novel high-performance line- drawing algorithms, and an API similar to a current standard. Three-dimensional imagery is created by projecting a series of 2-D bitmaps ('image slices') onto a diffuse screen that rotates at 600 rpm. Persistence of vision fuses the slices into a volume-filling 3-D image. A modified three-panel Texas Instruments projector provides slices at approximately 4 kHz, resulting in 8-color 3-D imagery comprised of roughly 200 radially-disposed slices which are updated at 20 Hz. Each slice has a resolution of 768 by 768 pixels, subtending 10 inches. An unusual off-axis projection scheme incorporating tilted rotating optics is used to maintain good focus across the projection screen. The display electronics includes a custom rasterization architecture which converts the user's 3- D geometry data into image slices, as well as 6 Gbits of DDR SDRAM graphics memory.

  14. High-resolution three-dimensional mapping of semiconductor dopant potentials

    DEFF Research Database (Denmark)

    Twitchett, AC; Yates, TJV; Newcomb, SB

    2007-01-01

    Semiconductor device structures are becoming increasingly three-dimensional at the nanometer scale. A key issue that must be addressed to enable future device development is the three-dimensional mapping of dopant distributions, ideally under "working conditions". Here we demonstrate how a combin......Semiconductor device structures are becoming increasingly three-dimensional at the nanometer scale. A key issue that must be addressed to enable future device development is the three-dimensional mapping of dopant distributions, ideally under "working conditions". Here we demonstrate how...... a combination of electron holography and electron tomography can be used to determine quantitatively the three-dimensional electrostatic potential in an electrically biased semiconductor device with nanometer spatial resolution....

  15. Equilibrium: three-dimensional configurations

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    This chapter considers toroidal MHD configurations that are inherently three-dimensional. The motivation for investigation such complicated equilibria is that they possess the potential for providing toroidal confinement without the need of a net toroidal current. This leads to a number of advantages with respect to fusion power generation. First, the attractive feature of steady-state operation becomes more feasible since such configurations no longer require a toroidal current transformer. Second, with zero net current, one potentially dangerous class of MHD instabilities, the current-driven kink modes, is eliminated. Finally, three-dimensional configurations possess nondegenerate flux surfaces even in the absence of plasma pressure and plasma current. Although there is an enormous range of possible three-dimensional equilibria, the configurations of interest are accurately described as axisymmetric tori with superimposed helical fields; furthermore, they possess no net toroidal current. Instead, two different and less obvious restoring forces are developed: the helical sideband force and the toroidal dipole current force. Each is discussed in detail in Chapter 7. A detailed discussion of the parallel current constraint, including its physical significance, is given in section 7.2. A general analysis of helical sideband equilibria, along with a detailed description of the Elmo bumpy torus, is presented in sections 7.3 and 7.4. A general description of toroidal dipole-current equilibria, including a detailed discussion of stellarators, heliotrons, and torsatrons, is given in sections 7.5 and 7.6

  16. Three-dimensional nanostructure determination from a large diffraction data set recorded using scanning electron nanodiffraction

    Directory of Open Access Journals (Sweden)

    Yifei Meng

    2016-09-01

    Full Text Available A diffraction-based technique is developed for the determination of three-dimensional nanostructures. The technique employs high-resolution and low-dose scanning electron nanodiffraction (SEND to acquire three-dimensional diffraction patterns, with the help of a special sample holder for large-angle rotation. Grains are identified in three-dimensional space based on crystal orientation and on reconstructed dark-field images from the recorded diffraction patterns. Application to a nanocrystalline TiN thin film shows that the three-dimensional morphology of columnar TiN grains of tens of nanometres in diameter can be reconstructed using an algebraic iterative algorithm under specified prior conditions, together with their crystallographic orientations. The principles can be extended to multiphase nanocrystalline materials as well. Thus, the tomographic SEND technique provides an effective and adaptive way of determining three-dimensional nanostructures.

  17. Development of a Three-Dimensional Hand Model Using Three-Dimensional Stereophotogrammetry: Assessment of Image Reproducibility.

    Directory of Open Access Journals (Sweden)

    Inge A Hoevenaren

    Full Text Available Using three-dimensional (3D stereophotogrammetry precise images and reconstructions of the human body can be produced. Over the last few years, this technique is mainly being developed in the field of maxillofacial reconstructive surgery, creating fusion images with computed tomography (CT data for precise planning and prediction of treatment outcome. Though, in hand surgery 3D stereophotogrammetry is not yet being used in clinical settings.A total of 34 three-dimensional hand photographs were analyzed to investigate the reproducibility. For every individual, 3D photographs were captured at two different time points (baseline T0 and one week later T1. Using two different registration methods, the reproducibility of the methods was analyzed. Furthermore, the differences between 3D photos of men and women were compared in a distance map as a first clinical pilot testing our registration method.The absolute mean registration error for the complete hand was 1.46 mm. This reduced to an error of 0.56 mm isolating the region to the palm of the hand. When comparing hands of both sexes, it was seen that the male hand was larger (broader base and longer fingers than the female hand.This study shows that 3D stereophotogrammetry can produce reproducible images of the hand without harmful side effects for the patient, so proving to be a reliable method for soft tissue analysis. Its potential use in everyday practice of hand surgery needs to be further explored.

  18. Three-dimensional bio-printing.

    Science.gov (United States)

    Gu, Qi; Hao, Jie; Lu, YangJie; Wang, Liu; Wallace, Gordon G; Zhou, Qi

    2015-05-01

    Three-dimensional (3D) printing technology has been widely used in various manufacturing operations including automotive, defence and space industries. 3D printing has the advantages of personalization, flexibility and high resolution, and is therefore becoming increasingly visible in the high-tech fields. Three-dimensional bio-printing technology also holds promise for future use in medical applications. At present 3D bio-printing is mainly used for simulating and reconstructing some hard tissues or for preparing drug-delivery systems in the medical area. The fabrication of 3D structures with living cells and bioactive moieties spatially distributed throughout will be realisable. Fabrication of complex tissues and organs is still at the exploratory stage. This review summarize the development of 3D bio-printing and its potential in medical applications, as well as discussing the current challenges faced by 3D bio-printing.

  19. Acid-base properties of complexes with three-dimensional polyligands. Complexes with three-dimensional polyphosphoric acids

    International Nuclear Information System (INIS)

    Kopylova, V.D.; Bojko, Eh.T.; Saldadze, K.M.

    1985-01-01

    By the method of potentiometric titration acid-base properties of uranyl (2) complexes with three-dimensional polyphosphoric acids, KRF-8p, KF-1, KF-7 prepared by phosphorylation of copolymer of styrene and divinylbenzene or saponification of the copolymers of di-2,2'-chloroethyl ester of vinylphosphonic acid with divinyl benzene are studied. It is shown that in case of formation in the phase of three-dimensional polyphosphoric acids of UO 2 2+ complexes with the growth of bond covalence of metal ion-phosphonic group the acidjty of the second hydroxyl of the phosphonic group increases

  20. Value of three-dimensional volume rendering images in the assessment of the centrality index for preoperative planning in patients with renal masses.

    Science.gov (United States)

    Sofia, C; Magno, C; Silipigni, S; Cantisani, V; Mucciardi, G; Sottile, F; Inferrera, A; Mazziotti, S; Ascenti, G

    2017-01-01

    To evaluate the precision of the centrality index (CI) measurement on three-dimensional (3D) volume rendering technique (VRT) images in patients with renal masses, compared to its standard measurement on axial images. Sixty-five patients with renal lesions underwent contrast-enhanced multidetector (MD) computed tomography (CT) for preoperative imaging. Two readers calculated the CI on two-dimensional axial images and on VRT images, measuring it in the plane that the tumour and centre of the kidney were lying in. Correlation and agreement of interobserver measurements and inter-method results were calculated using intraclass correlation (ICC) coefficients and the Bland-Altman method. Time saving was also calculated. The correlation coefficients were r=0.99 (ppresent study showed that VRT and axial images produce almost identical values of CI, with the advantages of greater ease of execution and a time saving of almost 50% for 3D VRT images. In addition, VRT provides an integrated perspective that can better assist surgeons in clinical decision making and in operative planning, suggesting this technique as a possible standard method for CI measurement. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Three-dimensional Ca2+ imaging advances understanding of astrocyte biology.

    Science.gov (United States)

    Bindocci, Erika; Savtchouk, Iaroslav; Liaudet, Nicolas; Becker, Denise; Carriero, Giovanni; Volterra, Andrea

    2017-05-19

    Astrocyte communication is typically studied by two-dimensional calcium ion (Ca 2+ ) imaging, but this method has not yielded conclusive data on the role of astrocytes in synaptic and vascular function. We developed a three-dimensional two-photon imaging approach and studied Ca 2+ dynamics in entire astrocyte volumes, including during axon-astrocyte interactions. In both awake mice and brain slices, we found that Ca 2+ activity in an individual astrocyte is scattered throughout the cell, largely compartmented between regions, preponderantly local within regions, and heterogeneously distributed regionally and locally. Processes and endfeet displayed frequent fast activity, whereas the soma was infrequently active. In awake mice, activity was higher than in brain slices, particularly in endfeet and processes, and displayed occasional multifocal cellwide events. Astrocytes responded locally to minimal axonal firing with time-correlated Ca 2+ spots. Copyright © 2017, American Association for the Advancement of Science.

  2. Three-Dimensional Anatomic Evaluation of the Anterior Cruciate Ligament for Planning Reconstruction

    Directory of Open Access Journals (Sweden)

    Yuichi Hoshino

    2012-01-01

    Full Text Available Anatomic study related to the anterior cruciate ligament (ACL reconstruction surgery has been developed in accordance with the progress of imaging technology. Advances in imaging techniques, especially the move from two-dimensional (2D to three-dimensional (3D image analysis, substantially contribute to anatomic understanding and its application to advanced ACL reconstruction surgery. This paper introduces previous research about image analysis of the ACL anatomy and its application to ACL reconstruction surgery. Crucial bony landmarks for the accurate placement of the ACL graft can be identified by 3D imaging technique. Additionally, 3D-CT analysis of the ACL insertion site anatomy provides better and more consistent evaluation than conventional “clock-face” reference and roentgenologic quadrant method. Since the human anatomy has a complex three-dimensional structure, further anatomic research using three-dimensional imaging analysis and its clinical application by navigation system or other technologies is warranted for the improvement of the ACL reconstruction.

  3. Three dimensional periodic foundations for base seismic isolation

    International Nuclear Information System (INIS)

    Yan, Y; Mo, Y L; Cheng, Z; Shi, Z; Menq, F; Tang, Y

    2015-01-01

    Based on the concept of phononic crystals, periodic foundations made of periodic materials are investigated in this paper. The periodic foundations can provide low frequency band gaps, which cover the main frequency ranges of seismic waves. Therefore, the periodic foundations are able to protect the upper structures during earthquake events. In this paper, the basic theory of three dimensional periodic foundations is studied and the finite element method was used to conduct the sensitivity study. A simplified three-dimensional periodic foundation with a superstructure was tested in the field and the feasibility of three dimensional periodic foundations was proved. The test results showed that the response of the upper structure with the three dimensional periodic foundation was reduced under excitation waves with the main frequency falling in the attenuation zones. The finite element analysis results are consistent with the experimental data, indicating that three dimensional periodic foundations are a feasible way of reducing seismic vibrations. (paper)

  4. Large Eddy Simulations of the Flow in a Three-Dimensional Ventilated Room

    DEFF Research Database (Denmark)

    Davidson, Lars; Nielsen, Peter V.

    We have done Large Eddy Simulations (LES) of the flow in a three-dimensional ventilated room. A finite volume method is used with a collocated grid arrangement. The momentum equations are solved with an explicit method using central differencing for all terms. The pressure is obtained from a Pois...... a Poisson equation, which is solved with a conjugate gradient method. For the discretization in time we use the Adam-Bashfourth scheme, which is second-order accurate....

  5. Simulation on three dimensional bubble formation using MARS

    International Nuclear Information System (INIS)

    Kunugi, Tomoaki

    1997-01-01

    This paper describes a numerical simulation on three-dimensional bubble formation by means of the MARS (Multi-interfaces Advection and Reconstruction Solver) developed by the author. The comparison between two-dimensional and three-dimensional simulation on an agglomeration of two bubbles is discussed. Moreover, some simulation results regarding a phase change phenomena such as a boiling and condensation in a two dimensional enclosure with heated and cooled walls are presented. (author)

  6. Scanning three-dimensional x-ray diffraction microscopy using a high-energy microbeam

    International Nuclear Information System (INIS)

    Hayashi, Y.; Hirose, Y.; Seno, Y.

    2016-01-01

    A scanning three-dimensional X-ray diffraction (3DXRD) microscope apparatus with a high-energy microbeam was installed at the BL33XU Toyota beamline at SPring-8. The size of the 50 keV beam focused using Kirkpatrick-Baez mirrors was 1.3 μm wide and 1.6 μm high in full width at half maximum. The scanning 3DXRD method was tested for a cold-rolled carbon steel sheet sample. A three-dimensional orientation map with 37 "3 voxels was obtained.

  7. Scanning three-dimensional x-ray diffraction microscopy using a high-energy microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Y., E-mail: y-hayashi@mosk.tytlabs.co.jp; Hirose, Y.; Seno, Y. [Toyota Central R& D Toyota Central R& D Labs., Inc., 41-1 Nagakute Aichi 480-1192 Japan (Japan)

    2016-07-27

    A scanning three-dimensional X-ray diffraction (3DXRD) microscope apparatus with a high-energy microbeam was installed at the BL33XU Toyota beamline at SPring-8. The size of the 50 keV beam focused using Kirkpatrick-Baez mirrors was 1.3 μm wide and 1.6 μm high in full width at half maximum. The scanning 3DXRD method was tested for a cold-rolled carbon steel sheet sample. A three-dimensional orientation map with 37 {sup 3} voxels was obtained.

  8. Full parallax three-dimensional computer generated hologram with occlusion effect using ray casting technique

    International Nuclear Information System (INIS)

    Zhang, Hao; Tan, Qiaofeng; Jin, Guofan

    2013-01-01

    Holographic display is capable of reconstructing the whole optical wave field of a three-dimensional (3D) scene. It is the only one among all the 3D display techniques that can produce all the depth cues. With the development of computing technology and spatial light modulators, computer generated holograms (CGHs) can now be used to produce dynamic 3D images of synthetic objects. Computation holography becomes highly complicated and demanding when it is employed to produce real 3D images. Here we present a novel algorithm for generating a full parallax 3D CGH with occlusion effect, which is an important property of 3D perception, but has often been neglected in fully computed hologram synthesis. The ray casting technique, which is widely used in computer graphics, is introduced to handle the occlusion issue of CGH computation. Horizontally and vertically distributed rays are projected from each hologram sample to the 3D objects to obtain the complex amplitude distribution. The occlusion issue is handled by performing ray casting calculations to all the hologram samples. The proposed algorithm has no restriction on or approximation to the 3D objects, and hence it can produce reconstructed images with correct shading effect and no visible artifacts. Programmable graphics processing unit (GPU) is used to perform parallel calculation. This is made possible because each hologram sample belongs to an independent operation. To demonstrate the performance of our proposed algorithm, an optical experiment is performed to reconstruct the 3D scene by using a phase-only spatial light modulator. We can easily perceive the accommodation cue by focusing our eyes on different depths of the scene and the motion parallax cue with occlusion effect by moving our eyes around. The experiment result confirms that the CGHs produced by our algorithm can successfully reconstruct 3D images with all the depth cues.

  9. Three-dimensional graphene/polyaniline composite material for high-performance supercapacitor applications

    International Nuclear Information System (INIS)

    Liu, Huili; Wang, Yi; Gou, Xinglong; Qi, Tao; Yang, Jun; Ding, Yulong

    2013-01-01

    Highlights: ► A novel 3D graphene showed high specific surface area and large mesopore volume. ► Aniline monomer was polymerized in the presence of 3D graphene at room temperature. ► The supercapacitive properties were studied by CV and charge–discharge tests. ► The composite show a high gravimetric capacitance and good cyclic stability. ► The 3D graphene/polyaniline has never been report before our work. -- Abstract: A novel three-dimensional (3D) graphene/polyaniline nanocomposite material which is synthesized using in situ polymerization of aniline monomer on the graphene surface is reported as an electrode for supercapacitors. The morphology and structure of the material are characterized by scanning electron microscopy (SEM), transmission electron microscope (TEM), Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD). The electrochemical properties of the resulting materials are systematically studied using cyclic voltammetry (CV) and constant current charge–discharge tests. A high gravimetric capacitance of 463 F g −1 at a scan rate of 1 mV s −1 is obtained by means of CVs with 3 mol L −1 KOH as the electrolyte. In addition, the composite material shows only 9.4% capacity loss after 500 cycles, indicating better cyclic stability for supercapacitor applications. The high specific surface area, large mesopore volume and three-dimensional nanoporous structure of 3D graphene could contribute to the high specific capacitance and good cyclic life

  10. An efficient semi-implicit method for three-dimensional non-hydrostatic flows in compliant arterial vessels.

    Science.gov (United States)

    Fambri, Francesco; Dumbser, Michael; Casulli, Vincenzo

    2014-11-01

    Blood flow in arterial systems can be described by the three-dimensional Navier-Stokes equations within a time-dependent spatial domain that accounts for the elasticity of the arterial walls. In this article, blood is treated as an incompressible Newtonian fluid that flows through compliant vessels of general cross section. A three-dimensional semi-implicit finite difference and finite volume model is derived so that numerical stability is obtained at a low computational cost on a staggered grid. The key idea of the method consists in a splitting of the pressure into a hydrostatic and a non-hydrostatic part, where first a small quasi-one-dimensional nonlinear system is solved for the hydrostatic pressure and only in a second step the fully three-dimensional non-hydrostatic pressure is computed from a three-dimensional nonlinear system as a correction to the hydrostatic one. The resulting algorithm is robust, efficient, locally and globally mass conservative, and applies to hydrostatic and non-hydrostatic flows in one, two and three space dimensions. These features are illustrated on nontrivial test cases for flows in tubes with circular or elliptical cross section where the exact analytical solution is known. Test cases of steady and pulsatile flows in uniformly curved rigid and elastic tubes are presented. Wherever possible, axial velocity development and secondary flows are shown and compared with previously published results. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Reproducibility of three-dimensional ultrasound for the measurement of a niche in a caesarean scar and assessment of its shape

    NARCIS (Netherlands)

    Bij de Vaate, A.J.M.; Linskens, I.H.; van der Voet, L.F.; Twisk, J.W.R.; Brölmann, H.A.M.; Huirne, J.A.F.

    2015-01-01

    Abstract Objective To evaluate the inter- and intraobserver agreement for measurement of the size and volume of a niche and assessment of the shape, with the use of three-dimensional (3D) ultrasound. Study design In this reproducibility study, 20 3D ultrasound volumes of uteri with a niche were

  12. Three-dimensional numerical simulation of wave interaction with perforated quasi-ellipse caisson

    Directory of Open Access Journals (Sweden)

    Yong-xue Wang

    2011-03-01

    Full Text Available The finite difference method and the volume of fluid (VOF method were used to develop a three-dimensional numerical model to study wave interaction with a perforated caisson. The partial cell method was adopted to solve this type of problem for the first time. The validity of the present model, with and without the presence of caisson structures, was examined by comparing the model results with experimental data. Then, the numerical model was used to investigate the effects of various wave and structure parameters on the wave force and wave runup of the perforated quasi-ellipse caisson. Compared with the solid quasi-ellipse caisson, the wave force on the perforated quasi-ellipse caisson is significantly reduced with increasing porosity of the perforated quasi-ellipse caisson. Furthermore, the perforated quasi-ellipse caisson can also reduce the wave runup, and it tends to decrease with the increase of the porosity of the perforated quasi-ellipse caisson and the relative wave height.

  13. NUMERICAL RESEARCH ON THE THREE-DIMENSIONAL FIBER ORIENTATION DISTRIBUTION IN PLANAR SUSPENSION FLOWS

    Directory of Open Access Journals (Sweden)

    Qihua Zhang

    Full Text Available Abstract To describe flow-induced fiber orientation, the Fokker-Planck equation is widely applied in the processing of composites and fiber suspensions. The analytical solution only exists when the Péclet number is infinite. So developing a numerical method covering a full range of Péclet number is of great significance. To accurately solve the Fokker-Planck equation, a numerical scheme based on the finite volume method is developed. Using spherical symmetry, the boundary is discretized and formulated into a cyclic tridiagonal matrix which is further solved by the CTDMA algorithm. To examine its validity, benchmark tests over a wide range of Péclet number are performed in a simple shear flow. For Pe=∞, the results agree well with the analytical solutions. For the other Pe numbers, the results are compared to results available in the literature. The tests show that this algorithm is accurate, stable, and globally conservative. Furthermore, this algorithm can be extended and used to predict the three-dimensional orientation distribution of complex suspension flows.

  14. Analysis of piping response to thermal and operational transients

    International Nuclear Information System (INIS)

    Wang, C.Y.

    1987-01-01

    The reactor piping system is an extremely complex three-dimensional structure. Maintaining its structural integrity is essential to the safe operation of the reactor and the steam-supply system. In the safety analysis, various transient loads can be imposed on the piping which may cause plastic deformation and possible damage to the system, including those generated from hydrodynamic wave propagations, thermal and operational transients, as well as the seismic events. At Argonne National Laboratory (ANL), a three-dimensional (3-D) piping code, SHAPS, aimed for short-duration transients due to wave propagation, has been developed. Since 1984, the development work has been shifted to the long-duration accidents originating from the thermal and operational transient. As a result, a new version of the code, SHAPS-2, is being established. This paper describes many features related to this later development. To analyze piping response generated from thermal and operational transients, a 3-D implicit finite element algorithm has been developed for calculating the hoop, flexural, axial, and torsional deformations induced by the thermomechanical loads. The analysis appropriately accounts for stresses arising from the temperature dependence of the elastic material properties, the thermal expansion of the materials, and the changes in the temperature-dependent yield surface. Thermal softening, failure, strain rate, creep, and stress ratching can also be considered

  15. Quantification of pneumothorax volume on chest radiographs: comparison between the collins' and the axel's methods with three-dimensional CT as the standard of reference

    International Nuclear Information System (INIS)

    Lee, Chang Keun; Kim, Hyung Jin; Lee, Kyung Hee; Kim, Joung Taek; Kim, Kwang Ho; Suh, Chang Hae; Han, Heon

    1999-01-01

    The purpose of this study was twofold. In a preliminary study, we evaluated the accuracy of 3-D (three-dimensional) CT for the estimation of pneumothorax volume and for providing the optimal postprocessing method for clinical study. In the clinical study, we determined which of the two methods, Collins' and Axel's, was more accurate for the estimation of pneumothorax volume, as seen on chest radiographs, using 3-D CT as the standard of reference. In the preliminary study, 3-D CT was applied to phantoms and to four patients with pneumothorax using two different postprocessing methods, manual contour delineation and thresholding. In the clinical study, 3-D CT was performed in 13 patients with pneumothorax. For the purpose of evaluating conventional radiographs, a localizer scan was used for comparing the accuracy of Collins' method with that of Axel's method, with 3-D CT as the standard of reference. The preliminary study revealed that 3-D CT estimated pneumothorax volume with great accuracy and that manual contour delineation and thresholding measured volume equally well. Because of the shorter postprocessing time required with thresholding than with manual contour delineation (5 min versus 30 min), the former was used during clinical study. The results of this indicated close correlation between the measurements obtained using Collins' method on chest radiographs and those obtained by 3-D CT(r=0.95, p 0.05). 3-D CT can estimate pneumothorax volume with great accuracy. Collins' method is superior to Axel's method for the quantification of pneumothorax volume as seen on chest radiographs

  16. MR cisternography with three-dimensional fast advanced spin-echo (FASE)

    International Nuclear Information System (INIS)

    Ohgi, Kazuyuki; Yamamoto, Hidefumi; Yokote, Hiroyuki

    2000-01-01

    To evaluate the usefulness of MR cisternography (MRC) combined with various postprocessing techniques and three-dimensional (3D) time-of-flight (TOF) MR angiography, MR cisternograms in 212 patients with various cranial nerve symptoms were retrospectively evaluated. MR examinations were performed with a 1.5 T MR imager using a 3D fast advanced spin-echo (FASE) sequence. Maximum intensity projection (MIP) had the advantage of demonstrating fluid-filled structures such as cerebrospinal fluid (CSF)-internal auditory canal (IAC) and Meckel's cave. Minimum intensity projection (Min IP) was especially useful in delineating neurovascular structures (NVS) in wide CSF space. Addition provided the most well-balanced images of NVS, and was superior to Min IP in the depiction of NVS in narrow CSF space. Virtual endoscopy and volume rendering had the potential to provide additional information in the evaluation of the three-dimensional relationships of NVS. Combination of 3D TOF MRA with MRC was helpful in differentiating arteries, veins, and nerves. With the judicious use of various postprocessing techniques and combined MRA, the value of MRC in the evaluation of patients with various cranial nerve symptoms can be further strengthened. (author)

  17. MR cisternography with three-dimensional fast advanced spin-echo (FASE)

    Energy Technology Data Exchange (ETDEWEB)

    Ohgi, Kazuyuki; Yamamoto, Hidefumi; Yokote, Hiroyuki [Japanese Red-Cross Medical Center, Tokyo (Japan)] [and others

    2000-06-01

    To evaluate the usefulness of MR cisternography (MRC) combined with various postprocessing techniques and three-dimensional (3D) time-of-flight (TOF) MR angiography, MR cisternograms in 212 patients with various cranial nerve symptoms were retrospectively evaluated. MR examinations were performed with a 1.5 T MR imager using a 3D fast advanced spin-echo (FASE) sequence. Maximum intensity projection (MIP) had the advantage of demonstrating fluid-filled structures such as cerebrospinal fluid (CSF)-internal auditory canal (IAC) and Meckel's cave. Minimum intensity projection (Min IP) was especially useful in delineating neurovascular structures (NVS) in wide CSF space. Addition provided the most well-balanced images of NVS, and was superior to Min IP in the depiction of NVS in narrow CSF space. Virtual endoscopy and volume rendering had the potential to provide additional information in the evaluation of the three-dimensional relationships of NVS. Combination of 3D TOF MRA with MRC was helpful in differentiating arteries, veins, and nerves. With the judicious use of various postprocessing techniques and combined MRA, the value of MRC in the evaluation of patients with various cranial nerve symptoms can be further strengthened. (author)

  18. Real-Time Three-Dimensional Echocardiography: Characterization of Cardiac Anatomy and Function-Current Clinical Applications and Literature Review Update.

    Science.gov (United States)

    Velasco, Omar; Beckett, Morgan Q; James, Aaron W; Loehr, Megan N; Lewis, Taylor G; Hassan, Tahmin; Janardhanan, Rajesh

    2017-01-01

    Our review of real-time three-dimensional echocardiography (RT3DE) discusses the diagnostic utility of RT3DE and provides a comparison with two-dimensional echocardiography (2DE) in clinical cardiology. A Pubmed literature search on RT3DE was performed using the following key words: transthoracic, two-dimensional, three-dimensional, real-time, and left ventricular (LV) function. Articles included perspective clinical studies and meta-analyses in the English language, and focused on the role of RT3DE in human subjects. Application of RT3DE includes analysis of the pericardium, right ventricular (RV) and LV cavities, wall motion, valvular disease, great vessels, congenital anomalies, and traumatic injury, such as myocardial contusion. RT3DE, through a transthoracic echocardiography (TTE), allows for increasingly accurate volume and valve motion assessment, estimated LV ejection fraction, and volume measurements. Chamber motion and LV mass approximation have been more accurately evaluated by RT3DE by improved inclusion of the third dimension and quantification of volumetric movement. Moreover, RT3DE was shown to have no statistical significance when comparing the ejection fractions of RT3DE to cardiac magnetic resonance (CMR). Analysis of RT3DE data sets of the LV endocardial exterior allows for the volume to be directly quantified for specific phases of the cardiac cycle, ranging from end systole to end diastole, eliminating error from wall motion abnormalities and asymmetrical left ventricles. RT3DE through TTE measures cardiac function with superior diagnostic accuracy in predicting LV mass, systolic function, along with LV and RV volume when compared with 2DE with comparable results to CMR.

  19. Volume-monitored chest CT: a simplified method for obtaining motion-free images near full inspiratory and end expiratory lung volumes

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Kathryn S. [The Ohio State University College of Medicine, Columbus, OH (United States); Long, Frederick R. [Nationwide Children' s Hospital, The Children' s Radiological Institute, Columbus, OH (United States); Flucke, Robert L. [Nationwide Children' s Hospital, Department of Pulmonary Medicine, Columbus, OH (United States); Castile, Robert G. [The Research Institute at Nationwide Children' s Hospital, Center for Perinatal Research, Columbus, OH (United States)

    2010-10-15

    Lung inflation and respiratory motion during chest CT affect diagnostic accuracy and reproducibility. To describe a simple volume-monitored (VM) method for performing reproducible, motion-free full inspiratory and end expiratory chest CT examinations in children. Fifty-two children with cystic fibrosis (mean age 8.8 {+-} 2.2 years) underwent pulmonary function tests and inspiratory and expiratory VM-CT scans (1.25-mm slices, 80-120 kVp, 16-40 mAs) according to an IRB-approved protocol. The VM-CT technique utilizes instruction from a respiratory therapist, a portable spirometer and real-time documentation of lung volume on a computer. CT image quality was evaluated for achievement of targeted lung-volume levels and for respiratory motion. Children achieved 95% of vital capacity during full inspiratory imaging. For end expiratory scans, 92% were at or below the child's end expiratory level. Two expiratory exams were judged to be at suboptimal volumes. Two inspiratory (4%) and three expiratory (6%) exams showed respiratory motion. Overall, 94% of scans were performed at optimal volumes without respiratory motion. The VM-CT technique is a simple, feasible method in children as young as 4 years to achieve reproducible high-quality full inspiratory and end expiratory lung CT images. (orig.)

  20. Three-dimensional tori and Arnold tongues

    Energy Technology Data Exchange (ETDEWEB)

    Sekikawa, Munehisa, E-mail: sekikawa@cc.utsunomiya-u.ac.jp [Department of Mechanical and Intelligent Engineering, Utsunomiya University, Utsunomiya-shi 321-8585 (Japan); Inaba, Naohiko [Organization for the Strategic Coordination of Research and Intellectual Property, Meiji University, Kawasaki-shi 214-8571 (Japan); Kamiyama, Kyohei [Department of Electronics and Bioinformatics, Meiji University, Kawasaki-shi 214-8571 (Japan); Aihara, Kazuyuki [Institute of Industrial Science, the University of Tokyo, Meguro-ku 153-8505 (Japan)

    2014-03-15

    This study analyzes an Arnold resonance web, which includes complicated quasi-periodic bifurcations, by conducting a Lyapunov analysis for a coupled delayed logistic map. The map can exhibit a two-dimensional invariant torus (IT), which corresponds to a three-dimensional torus in vector fields. Numerous one-dimensional invariant closed curves (ICCs), which correspond to two-dimensional tori in vector fields, exist in a very complicated but reasonable manner inside an IT-generating region. Periodic solutions emerge at the intersections of two different thin ICC-generating regions, which we call ICC-Arnold tongues, because all three independent-frequency components of the IT become rational at the intersections. Additionally, we observe a significant bifurcation structure where conventional Arnold tongues transit to ICC-Arnold tongues through a Neimark-Sacker bifurcation in the neighborhood of a quasi-periodic Hopf bifurcation (or a quasi-periodic Neimark-Sacker bifurcation) boundary.

  1. Self-diffusion in monodisperse three-dimensional magnetic fluids by molecular dynamics simulations

    Energy Technology Data Exchange (ETDEWEB)

    Dobroserdova, A.B. [Ural Federal University, Lenin Av. 51, Ekaterinburg (Russian Federation); Kantorovich, S.S., E-mail: alla.dobroserdova@urfu.ru [Ural Federal University, Lenin Av. 51, Ekaterinburg (Russian Federation); University of Vienna, Sensengasse 8, Vienna (Austria)

    2017-06-01

    In the present work we study the self-diffusion behaviour in the three-dimensional monodisperse magnetic fluids using the Molecular Dynamics Simulation and Density Functional Theory. The peculiarity of computer simulation is to study two different systems: dipolar and soft sphere ones. In the theoretical method, it is important to choose the approximation for the main structures, which are chains. We compare the theoretical results and the computer simulation data for the self-diffusion coefficient as a function of the particle volume fraction and magnetic dipole-dipole interaction parameter and find the qualitative and quantitative agreement to be good. - Highlights: • The paper deals with the study of the self-diffusion in monodisperse three-dimensional magnetic fluids. • The theoretical approach contains the free energy density functional minimization. • Computer simulations are performed by the molecular dynamics method. • We have a good qualitative and quantitative agreement between the theoretical results and computer simulation data.

  2. THREE-DIMENSIONAL WEB-BASED PHYSICS SIMULATION APPLICATION FOR PHYSICS LEARNING TOOL

    Directory of Open Access Journals (Sweden)

    William Salim

    2012-10-01

    Full Text Available The purpose of this research is to present a multimedia application for doing simulation in Physics. The application is a web based simulator that implementing HTML5, WebGL, and JavaScript. The objects and the environment will be in three dimensional views. This application is hoped will become the substitute for practicum activity. The current development is the application only covers Newtonian mechanics. Questionnaire and literature study is used as the data collecting method. While Waterfall Method used as the design method. The result is Three-DimensionalPhysics Simulator as online web application. Three-Dimensionaldesign and mentor-mentee relationship is the key features of this application. The conclusion made is Three-DimensionalPhysics Simulator already fulfilled in both design and functionality according to user. This application also helps them to understand Newtonian mechanics by simulation. Improvements are needed, because this application only covers Newtonian Mechanics. There is a lot possibility in the future that this simulation can also covers other Physics topic, such as optic, energy, or electricity.Keywords: Simulation, Physic, Learning Tool, HTML5, WebGL

  3. Age and prostate volume are risk factors for transient urinary incontinence after transurethral enucleation with bipolar for benign prostatic hyperplasia.

    Science.gov (United States)

    Hirasawa, Yosuke; Kato, Yuji; Fujita, Kiichiro

    2018-01-01

    To investigate the predictive factors for transient urinary incontinence after transurethral enucleation with bipolar. We retrospectively analyzed the data of 584 patients who underwent transurethral enucleation with bipolar between December 2011 and September 2016 operated by a single surgeon. Urinary incontinence after transurethral enucleation with bipolar was defined as involuntary leakage of urine that required the use of pads. It was evaluated at 1 week, and 1, 3, 6, 12 and 24 months after transurethral enucleation with bipolar. We defined transient urinary incontinence as urinary incontinence persisting up to 1 month after transurethral enucleation with bipolar. Based on independent risk factors identified by a multivariate stepwise logistic regression analysis, a nomogram to predict transient urinary incontinence was developed. Of the 584 patients, 17.3%, 13.5%, 3.1%, 0.41%, and 0% patients had urinary incontinence at 1 week, 1, 3, 6 and 12 months after transurethral enucleation with bipolar, respectively. The mean (±standard error) age was 69.6 ± 0.26 years, estimated prostate volume was 54.7 ± 0.91 cm 3 , operative time was 58.0 ± 1.1 min and the prostate specimen weight was 30.6 ± 0.69 g. On univariate analysis, age, prostate volume estimated by transrectal ultrasonography, prostate-specific antigen, prostate specimen weight, operative time, prostate specimen weight/prostate volume and prostate specimen weight/operative time were significant predictive factors for transient urinary incontinence after transurethral enucleation with bipolar. On multivariate analysis, age (hazard ratio 1.07, P-value = 0.0034) and prostate volume (hazard ratio 1.03, P-value bipolar. Age and prostate volume estimated by transrectal ultrasonography seem to represent significant independent risk factors for transient urinary incontinence after transurethral enucleation with bipolar. This should be well discussed with the patient before surgery. © 2017 The Japanese

  4. Making three-dimensional echocardiography more tangible: a workflow for three-dimensional printing with echocardiographic data

    Directory of Open Access Journals (Sweden)

    Azad Mashari MD

    2016-12-01

    Full Text Available Three-dimensional (3D printing is a rapidly evolving technology with several potential applications in the diagnosis and management of cardiac disease. Recently, 3D printing (i.e. rapid prototyping derived from 3D transesophageal echocardiography (TEE has become possible. Due to the multiple steps involved and the specific equipment required for each step, it might be difficult to start implementing echocardiography-derived 3D printing in a clinical setting. In this review, we provide an overview of this process, including its logistics and organization of tools and materials, 3D TEE image acquisition strategies, data export, format conversion, segmentation, and printing. Generation of patient-specific models of cardiac anatomy from echocardiographic data is a feasible, practical application of 3D printing technology.

  5. PARALLEL ALGORITHM FOR THREE-DIMENSIONAL STOKES FLOW SIMULATION USING BOUNDARY ELEMENT METHOD

    Directory of Open Access Journals (Sweden)

    D. G. Pribytok

    2016-01-01

    Full Text Available Parallel computing technique for modeling three-dimensional viscous flow (Stokes flow using direct boundary element method is presented. The problem is solved in three phases: sampling and construction of system of linear algebraic equations (SLAE, its decision and finding the velocity of liquid at predetermined points. For construction of the system and finding the velocity, the parallel algorithms using graphics CUDA cards programming technology have been developed and implemented. To solve the system of linear algebraic equations the implemented software libraries are used. A comparison of time consumption for three main algorithms on the example of calculation of viscous fluid motion in three-dimensional cavity is performed.

  6. Three-dimensional ultrasonic imaging of concrete elements using different SAFT data acquisition and processing schemes

    International Nuclear Information System (INIS)

    Schickert, Martin

    2015-01-01

    Ultrasonic testing systems using transducer arrays and the SAFT (Synthetic Aperture Focusing Technique) reconstruction allow for imaging the internal structure of concrete elements. At one-sided access, three-dimensional representations of the concrete volume can be reconstructed in relatively great detail, permitting to detect and localize objects such as construction elements, built-in components, and flaws. Different SAFT data acquisition and processing schemes can be utilized which differ in terms of the measuring and computational effort and the reconstruction result. In this contribution, two methods are compared with respect to their principle of operation and their imaging characteristics. The first method is the conventional single-channel SAFT algorithm which is implemented using a virtual transducer that is moved within a transducer array by electronic switching. The second method is the Combinational SAFT algorithm (C-SAFT), also named Sampling Phased Array (SPA) or Full Matrix Capture/Total Focusing Method (TFM/FMC), which is realized using a combination of virtual transducers within a transducer array. Five variants of these two methods are compared by means of measurements obtained at test specimens containing objects typical of concrete elements. The automated SAFT imaging system FLEXUS is used for the measurements which includes a three-axis scanner with a 1.0 m × 0.8 m scan range and an electronically switched ultrasonic array consisting of 48 transducers in 16 groups. On the basis of two-dimensional and three-dimensional reconstructed images, qualitative and some quantitative results of the parameters image resolution, signal-to-noise ratio, measurement time, and computational effort are discussed in view of application characteristics of the SAFT variants

  7. High Patient Satisfaction of a Hyaluronic Acid Filler Producing Enduring Full-Facial Volume Restoration: An 18-Month Open Multicenter Study.

    Science.gov (United States)

    Talarico, Sergio; Meski, Ana P; Buratini, Laura; Manela-Azulay, Mônica; Simpson, Helen; Sidou, Farzaneh; Kerrouche, Nabil

    2015-12-01

    Volume restoration is an essential part of facial rejuvenation. To assess long-term full-facial volume restoration using HAEL Volume Lidocaine hyaluronic acid filler. An 18-month open study in 60 subjects with at least Grade 2 on the 4-point volume loss scale (VLS) for full face and at least 2 indications affected among chin, temporal areas, jawline, cheeks, cheekbones, and nasolabial folds (NLF). Performance was assessed by VLS, Lemperle rating scale (LRS), investigator Global Aesthetic Improvement Scale (GAIS), and 3-dimensional (3D) imaging. Most subjects (71.6%) had 3 or 4 indications injected, most commonly cheekbones (96.7%) and NLF (93.3%). At 18 months, at least a 1-grade improvement in VLS was observed for full face (68.3% of subjects), chin (77.8%), temporal areas (73.7%), cheeks (66.6%), cheekbones (58.6%), jawline (43.1%), and NLF (71.4%; LRS). For all indications, more than 60% of the volume gained at 3 weeks was sustained at 18 months based on 3D digital imaging. At 18 months, 95.0% of subjects had improved full-face GAIS and all subjects were satisfied with their aesthetic outcome. One subject (1.6%) had treatment-related adverse events. Full-facial volume restoration was well sustained over 18 months with high patient satisfaction and good tolerability.

  8. Three dimensional conformal radiation therapy may improve the therapeutic ratio of radiation therapy after pneumonectomy for lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Trouette, R; Causse, N; Elkhadri, M; Caudry, M; Maire, J P; Houlard, J P; Racaldini, L; Demeaux, H

    1995-12-01

    Three dimensional conformal radiation therapy would allow to decrease the normal tissue dose while maintaining the same target dose as standard treatment. To evaluate the feasibility of normal tissue dose reduction for ten patients with pneumonectomy for lung cancer, we determined the dose distribution to the normal tissue with 3-dimensional conformal radiation therapy (3-DCRT) and conventional treatment planning (CTP). Dose-volume histograms for target and normal tissue (lung, heart) were used for comparison of the different treatment planning. The mean percentages of lung and heart volumes which received 40 Gy with 3-DCRT were respectively 63% and 37% of the mean percentage of lung and volumes which received the same dose with CTP. These preliminary results suggest that conformal therapy may improve the therapeutic ratio by reducing risk to normal tissue.

  9. Drag and drop simulation: from pictures to full three-dimensional simulations

    Science.gov (United States)

    Bergmann, Michel; Iollo, Angelo

    2014-11-01

    We present a suite of methods to achieve ``drag and drop'' simulation, i.e., to fully automatize the process to perform thee-dimensional flow simulations around a bodies defined by actual images of moving objects. The overall approach requires a skeleton graph generation to get level set function from pictures, optimal transportation to get body velocity on the surface and then flow simulation thanks to a cartesian method based on penalization. We illustrate this paradigm simulating the swimming of a mackerel fish.

  10. An Introduction of Three-dimensional Grammar

    Directory of Open Access Journals (Sweden)

    Fan Xiao

    2017-12-01

    Full Text Available This paper introduces some key points of Three-dimensional Grammar. As for the structure, it can be distinguished into syntactic structure, semantic structure and pragmatic structure from the perspectives of syntax, semantics and pragmatics. And the same is true with the followings, such as grammatical constituents, grammatical functions, grammatical meanings, grammatical focuses. Sentence types which is called sentence pattern, sentence model and sentence types respectively, and analysis methods. This paper proposes that grammatical researches should be done in accordance with the four principles, that is form and meaning co-verified, static and dynamic co-referenced, structure and function co-testified and description and interpretation co-promoted.

  11. A comparison of different three-dimensional treatment planning techniques for localized radiotherapy of prostate cancer

    International Nuclear Information System (INIS)

    Koswig, S.; Dinges, S.; Buchali, A.; Boehmer, D.; Salk, J.; Rosenthal, P.; Harder, C.; Schlenger, L.; Budach, V.

    1999-01-01

    Purpose: Four different three-dimensional planning techniques for localized radiotherapy of prostate cancer were compared with regard to dose homogeneity within the target volume and dose to organs at risk, dependent upon tumor stage. Patients and Methods: Six patients with stage T1, 7 patients with stage T2 and 4 patients with stage T3 were included in this study. Four different 3D treatment plans (rotation, 4-field, 5-field and 6-field technique) were calculated for each patient. Dose was calculated with the reference point at the isocenter (100%). The planning target volume was encompassed within the 95% isodose surface. All the techniques used different shaped portal for each beam. Dose volume histograms were created and compared for the planning target volume and the organs at risk (33%, 50%, 66% volume level) in all techniques. Results: The 4 different three-dimensional planning techniques revealed no differences concerning dose homogeneity within the planning target volume. The dose volume distribution at organs at risk show differences between the calculated techniques. In our study the best protection for bladder and rectum in stage T1 and T2 was achieved by the 6-field technique. A significant difference was achieved between 6-field and 4-field technique only in the 50% volume of the bladder (p=0.034), between the 6-field and rotation technique (all volume levels) and between 5-field and rotation technique (all volume levels). In stage T1, T2 6-field and 4-field technique in 50% (p-0.033) and 66% (p=0.011) of the rectum volume. In stage T3 a significant difference was not observed between the 4 techniques. The best protection of head of the femur was achieved by the rotation technique. Conclusion: In the localized radiotherapy of prostate cancer in stage T1 or T2 the best protection for bladder and rectum was achieved by a 3D-planned conformal 6-field technique. If the seminal vesicles have been included in the target volume and in the case of large

  12. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder.

    Science.gov (United States)

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-11-01

    The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound for inter-reader agreements

  13. Clinical utility of three-dimensional contrast-enhanced ultrasound in the differentiation between noninvasive and invasive neoplasms of urinary bladder

    International Nuclear Information System (INIS)

    Li, Qiu-yang; Tang, Jie; He, En-hui; Li, Yan-mi; Zhou, Yun; Zhang, Xu; Chen, Guangfu

    2012-01-01

    Objectives: The purpose of this study was to evaluate the effectiveness of three-dimensional contrast-enhanced ultrasound in differentiating invasive and noninvasive neoplasms of urinary bladder. Methods: A total of 60 lesions in 60 consecutive patients with bladder tumors received three dimensional ultrasonography, low acoustic power contrast enhanced ultrasonography and low acoustic power three-dimensional contrast-enhanced ultrasound examination. The IU22 ultrasound scanner and a volume transducer were used and the ultrasound contrast agent was SonoVue. The contrast-specific sonographic imaging modes were PI (pulse inversion) and PM (power modulation). The three dimensional ultrasonography, contrast enhanced ultrasonography, and three-dimensional contrast-enhanced ultrasound images were independently reviewed by two readers who were not in the images acquisition. Images were analyzed off-site. A level of confidence in the diagnosis of tumor invasion of the muscle layer was assigned on a 5° scale. Receiver operating characteristic analysis was used to assess overall confidence in the diagnosis of muscle invasion by tumor. Kappa values were used to assess inter-readers agreement. Histologic diagnosis was obtained for all patients. Results: Final pathologic staging revealed 44 noninvasive tumors and 16 invasive tumors. Three-dimensional contrast-enhanced ultrasound depicted all 16 muscle-invasive tumors. The diagnostic performance of three-dimensional contrast-enhanced ultrasound was better than those of three dimensional ultrasonography and contrast enhanced ultrasonography. The receiver operating characteristic curves were 0.976 and 0.967 for three-dimensional contrast-enhanced ultrasound, those for three dimensional ultrasonography were 0.881 and 0.869, those for contrast enhanced ultrasonography were 0.927 and 0.929. The kappa values in the three dimensional ultrasonography, contrast enhanced ultrasonography and three-dimensional contrast-enhanced ultrasound

  14. Automated three-dimensional X-ray analysis using a dual-beam FIB

    International Nuclear Information System (INIS)

    Schaffer, Miroslava; Wagner, Julian; Schaffer, Bernhard; Schmied, Mario; Mulders, Hans

    2007-01-01

    We present a fully automated method for three-dimensional (3D) elemental analysis demonstrated using a ceramic sample of chemistry (Ca)MgTiO x . The specimen is serially sectioned by a focused ion beam (FIB) microscope, and energy-dispersive X-ray spectrometry (EDXS) is used for elemental analysis of each cross-section created. A 3D elemental model is reconstructed from the stack of two-dimensional (2D) data. This work concentrates on issues arising from process automation, the large sample volume of approximately 17x17x10 μm 3 , and the insulating nature of the specimen. A new routine for post-acquisition data correction of different drift effects is demonstrated. Furthermore, it is shown that EDXS data may be erroneous for specimens containing voids, and that back-scattered electron images have to be used to correct for these errors

  15. The role of three-dimensional ultrasound in the differential diagnosis of

    Directory of Open Access Journals (Sweden)

    Mustafa Ersöz

    2011-03-01

    Full Text Available Gastroschisis and omphalocele are the two of the mostcommon malformations of the anterior abdominal wallthat both of them associated with high morbidity andmortality. Sometimes the diagnosis and the realization ofthe situations by physicians and the parents are difficult.Herein, one omphalocele and one gastroschisis caseswere presented with the two-dimensional and threedimensionalultrasonographic diagnostic features. Thetwo entities and the role of three-dimensionalultrasound in diagnosis and the clinical management ofthe situations are discussed in the view of medicalliterature. The three-dimensional ultrasound helps in thediagnosis and detection of the severity of theomphalocele and the gastroschisis. J Clin Exp Invest2011; 2(1: 106-109

  16. Design of a Large-scale Three-dimensional Flexible Arrayed Tactile Sensor

    Directory of Open Access Journals (Sweden)

    Junxiang Ding

    2011-01-01

    Full Text Available This paper proposes a new type of large-scale three-dimensional flexible arrayed tactile sensor based on conductive rubber. It can be used to detect three-dimensional force information on the continuous surface of the sensor, which realizes a true skin type tactile sensor. The widely used method of liquid rubber injection molding (LIMS method is used for "the overall injection molding" sample preparation. The structure details of staggered nodes and a new decoupling algorithm of force analysis are given. Simulation results show that the sensor based on this structure can achieve flexible measurement of large-scale 3-D tactile sensor arrays.

  17. Three-body unitarity in the finite volume

    Energy Technology Data Exchange (ETDEWEB)

    Mai, M. [The George Washington University, Washington, DC (United States); Doering, M. [The George Washington University, Washington, DC (United States); Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)

    2017-12-15

    The physical interpretation of lattice QCD simulations, performed in a small volume, requires an extrapolation to the infinite volume. A method is proposed to perform such an extrapolation for three interacting particles at energies above threshold. For this, a recently formulated relativistic 3 → 3 amplitude based on the isobar formulation is adapted to the finite volume. The guiding principle is two- and three-body unitarity that imposes the imaginary parts of the amplitude in the infinite volume. In turn, these imaginary parts dictate the leading power-law finite-volume effects. It is demonstrated that finite-volume poles arising from the singular interaction, from the external two-body sub-amplitudes, and from the disconnected topology cancel exactly leaving only the genuine three-body eigenvalues. The corresponding quantization condition is derived for the case of three identical scalar-isoscalar particles and its numerical implementation is demonstrated. (orig.)

  18. Three-dimensional CT of the pediatric spine

    International Nuclear Information System (INIS)

    Starshak, R.J.; Crawford, C.R.; Waisman, R.C.; Sty, J.R.

    1987-01-01

    CT of the spine has been shown to be useful in evaluating congenital, neoplastic, inflammatory, and traumatic lesions. Any portion of the neural arch may be involved by these disease processes. However, the complex nature of the spinal column can make evaluation of these abnormalities difficult on axial CT. This is especially true if the spine is distorted by scoliosis, kyphosis, or lordosis. The principal advantage of three-dimensional CT is its ability to display the surface relationships of complicated objects. The complexity of the spinal axis makes it ideal for study with three-dimensional CT. This presentation illustrates the advantages and drawbacks of three-dimensional CT in spinal abnormalities in children

  19. Model of Transient Process Where Three-Phase Transducer Feeds Induction Motor Equivalent as a Variable Active-Inductive Load

    Directory of Open Access Journals (Sweden)

    Nenad Marković

    2016-01-01

    Full Text Available The paper presents a new approach in the analysis of a transient state in a system where the feeding source is a transducer-IGBT inverter and load is introduced through the induction motor with its R-L parameters. Induction motors with different parameters of powers and power factors are tested. MATLAB simulation of the three-phase inverter that feeds the induction machine has replaced the missing lab equipment with which mathematical model of this system was verified. According to the selected parameters of the inverter and induction machine and through the simulation in the MATLAB program, the results are obtained in the form of diagrams that verify the model of a transient state of the induction machine operation when it operates as a motor which is presented as a variable R-L load. The transient process of the system three-phase bridge inverter whose active-inductive load is the induction machine in the conditions of the change of the load parameters is analyzed. The model of the transient process in the system formed by the inverter in PWM (Pulse Width Modulation converter and induction machine is developed in the time domain and phase coordinates.

  20. Three-dimensional deformation of orthodontic brackets

    Science.gov (United States)

    Melenka, Garrett W; Nobes, David S; Major, Paul W

    2013-01-01

    Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire–bracket interaction. An optical technique has been employed to measure the deformation due to size and geometric constraints of the orthodontic brackets. Images of orthodontic brackets are collected using a stereo microscope and two charge-coupled device cameras, and deformation of orthodontic brackets is measured using a three-dimensional digital image correlation technique. The three-dimensional deformation of orthodontic brackets will be evaluated. The repeatability of the three-dimensional digital image correlation measurement method was evaluated by performing 30 archwire rotation tests using the same bracket and archwire. Finally, five Damon 3MX and five In-Ovation R self-ligating brackets will be compared using this technique to demonstrate the effect of archwire rotation on bracket design. PMID:23762201