WorldWideScience

Sample records for fretting wear failure

  1. Test Methodology of Reproducing Fuel Rod Failure by Debris Fretting Wear

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Oh Joon; Park, Nam Gyu; Kim, Jae Ik [KEPCO NF, Daejeon (Korea, Republic of)

    2015-10-15

    A test was conducted with simple debris to reproduce debris fretting wear. 68% of fuel rod cladding thickness is worn out by Inconel debris in 75 hours. The test result shows that a simple link system is useful to accommodate debris oscillation, and mid grid mixing vanes could be a source of debris forcing. Additional tests will be conducted with various debris such as wire brush, metal chip, etc which are suspected to generate actual debris fretting wear in future works. Debris fretting is one of the most common cause of the nuclear fuel rod failure. Even the most of the nuclear fuels has debris protection system, debris still cause fuel rod failure. From 1994 to 2006, debris fretting failure is around 11% of the total fuel failure. In 2006-2010, the portion of debris rises to over 13%. The total number of fuel rods failure is decreasing, but the portion of the debris fretting wear is growing with time. Therefore reproducing and identifying the mechanism of fuel rod failure by debris fretting wear is needed to improve reliability of the nuclear fuel.

  2. Impact Fretting Wear Behavior of Alloy 690 Tubes in Dry and Deionized Water Conditions

    Science.gov (United States)

    Cai, Zhen-Bing; Peng, Jin-Fang; Qian, Hao; Tang, Li-Chen; Zhu, Min-Hao

    2017-07-01

    The impact fretting wear has largely occurred at nuclear power device induced by the flow-induced vibration, and it will take potential hazards to the service of the equipment. However, the present study focuses on the tangential fretting wear of alloy 690 tubes. Research on impact fretting wear of alloy 690 tubes is limited and the related research is imminent. Therefore, impact fretting wear behavior of alloy 690 tubes against 304 stainless steels is investigated. Deionized water is used to simulate the flow environment of the equipment, and the dry environment is used for comparison. Varied analytical techniques are employed to characterize the wear and tribochemical behavior during impact fretting wear. Characterization results indicate that cracks occur at high impact load in both water and dry equipment; however, the water as a medium can significantly delay the cracking time. The crack propagation behavior shows a jagged shape in the water, but crack extended disorderly in dry equipment because the water changed the stress distribution and retarded the friction heat during the wear process. The SEM and XPS analysis shows that the main failure mechanisms of the tube under impact fretting are fatigue wear and friction oxidation. The effect of medium(water) on fretting wear is revealed, which plays a potential and promising role in the service of nuclear power device and other flow equipments.

  3. Fretting wear behavior of AZ91D magnesium alloy

    Institute of Scientific and Technical Information of China (English)

    CHEN An-hua; HUANG Wei-jiu; LI Zhao-feng

    2006-01-01

    The fretting behaviour of the AZ91D magnesium alloy was investigated. The influence of the number of cycles, normal load (contact pressure) and the amplitude of slip on the fretting behavior of the material were focused. Fretting tests were performed under various running conditions with regard to normal load levels and slip amplitudes. The friction coefficient between the surfaces at the fretting junction was continuously recorded. The fretting damage on the magnesium specimens was studied by SEM. The results show that the wear volume increases with the increase of slip amplitude, and linearly increases with the increase of normal load in the mixed and gross slip regime, but the normal load has no obvious effect on the wear volume in the partial slip regime. The predominant fretting wear mechanism of magnesium alloy in the slip regime is the oxidation wear, delaminated wear and abrasive wear.

  4. Influence of Fretting Wear on Lifetime of Tin Plated Connectors

    Science.gov (United States)

    Ikeda, Hirosaka; Ito, Tetsuya; Sawada, Shigeru; Hattori, Yasuhiro; Saitoh, Yasushi; Tamai, Terutaka; Iida, Kazuo

    Due to the recent increase in electronic devices mounted on automobiles, a large number of connectors, especially low-cost tin plated connectors are being used. As a result, their contact reliability has become problematic. Furthermore, for the connectors which are subjected to fretting wear caused by heat cycle and vibrations, the contact resistance increases because of wear of tin and deposition of oxides, which generates problems of poor contact. This study is intended to analyze the change in contact resistance of tin plated connectors from the start of fretting wear to the end of their lifetime from the viewpoint of practical reliability, and to observe the trace and the characteristics of fretting wear microscopically. This study found that wear and oxidation of tin plated connectors start immediately with fretting wear, and thus accumulation of abrasion powder on fretting areas causes connectors to reach to the end of their useful lifetime quickly. Especially, it was demonstrated that amplitude of fretting has a considerable influence on a connector's lifetime. It is made clear that air-tightness, so-called “gas-tight” of tin in a fretting area influences fretting wear considerably.

  5. The role of oxidation in the fretting wear process

    Science.gov (United States)

    Bill, R. C.

    1980-01-01

    Fretting experiments were conducted on titanium, a series of Ni-Cr-Al alloys and on some high temperature turbine alloys at room temperature and at elevated temperatures in air and in various inert environments. It was found that, depending on temperature and environment, the fretting behavior of the materials examined could be classified according to four general types of behavior. Briefly, these types of behavior were: (1) the complete absence of oxidation, as in inert environments, generally leading to low rates of fretting wear but high fretting friction; (2) gradual attrition of surface oxide with each fretting stroke, found in these experiments to operate in concert with other dominating mechanisms; (3) rapid oxidation at surface fatigue damage sites, resulting in undermining and rapid disintegration of the load bearing surface; and (4) the formation of coherent, protective oxide film, resulting in low rates of fretting wear. An analytical model predicting conditions favorable to the fourth type of behavior was outlined.

  6. Low-Frequency Reciprocating Fretting Wear Testing System Design and Experiment Research

    Institute of Scientific and Technical Information of China (English)

    Zhongnan Wang∗,Wuyi Wang; Guangyu Zhang

    2015-01-01

    The fretting wear is resulted from different or same sample’ s surfaces by the small variationand leads to mechanism failures. The main factors consist of the variation of normal load and oscillation frequencies, among which surface topography of different materials are the main factors to the problems of the fretting wear. Therefore, a novel low⁃frequency reciprocating fretting wear test system is designed upon the principle of Friction coefficient measurement. Four metal and non⁃metallic samples are measured under various normal load and oscillation frequencies to obtain the instantaneous friction coefficient in the repeat experiments. In fact, the experimental results show that CoF curves of different samples with the increase of the normal load are the similar exponential decay or parabolic shapes, which are consistent with the literatures to verify the rational design and reliable⁃operation of the system under the conditions of different frequencies.

  7. Fretting wear behavior of nitrogen implanted Zircaloy-4 alloy

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Zircaloy-4 was implanted with nitrogen at 120keV with various ion doses between 1 × 1013 and 1 × 1014 ions/m2. Fretting wear tests were performed at various cycles and loads under water immersion condition by the fretting simulator, The implanted surfaces were analyzed by Auger electron spectroscopy (AES) and transmission electron microscope(TEM). Micro-hardnees tester measured surface hardness. It is shown that nitrogen imphantation produced Zirconium nitride oxide and high density dislocations in implanted ltyer, surface hardness was enhanced from HK280 for unimplantedspecimen to HK1800 for a total ion dose of 1 × 1014 ions/m2. The nitrogen ion implantation treatment provided significantimprovements in the resistance of fretting damage.

  8. A Study on Fretting Wear Property of CVD SiC and Sintered SiC

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Hyun-Jin; Jang, Ki-Nam; An, Ji-Hyeong; Kim, Kyu-Tae [Dongguk University, Gyeongju (Korea, Republic of)

    2015-10-15

    Silicon Carbide is broadly used as high temperature structure material because of its high temperature tolerance and superior mechanical properties. After the Fukushima nuclear power plant accident, SiC proposed as one of the alternative materials for LWR fuel cladding to provide enhanced safety margin. Grid-to-rod fretting wear-induced fuel failure is known to occur due to flow-induced vibration of the reactor core and grid to- rod gap. In this paper, wear tests for CVD SiC plate and sintered SiC tube were performed with two types of spacer grids. Wear test of corroded and non-corroded CVD SiC plates indicate that wear resistance of corroded specimen is lower than one of non-corroded specimen in contrast with zirconium alloy cladding tube. It may be affected by rough surface of corroded specimen caused by grain boundary attack.

  9. Fretting Wear Behavior of Tin Plated Contacts:. Influence on Contact Resistance

    Science.gov (United States)

    Park, Young Woo; Sankara Narayanan, T. S. N.; Lee, Kang Yong

    The fretting wear behavior of tin plated copper alloy contacts and its influence on the contact resistance are addressed in this paper. Based on the change in the area of contact zone as well as the wear depth as a function of fretting cycles, a model was proposed to explain the observed low and stable contact resistance. The extent of wear of tin coating and the formation of wear debris as a function of fretting cycles were assessed by scanning electron microscopy (SEM). Energy dispersive X-ray line scanning (EDX), X-ray mapping, and EDX spot analysis were employed to characterize the nature of changes that occur at the contact zone. The study reveals that the fretted area increases linearly up to 8000 cycles due to the continuous removal of the tin coating and attains saturation when the fretting path length reaches a maximum. The observed low and stable contact resistance observed up to 8000 cycles is due to the common area of contact which provides an electrically conducting area. Surface analysis by SEM, EDX, and X-ray elemental mapping elucidate the nature of changes that occurred at the contact zone. Based on the change in contact resistance as a function of fretting cycles, the fretting wear and fretting corrosion dominant regimes are proposed. The interdependence of extent of wear and oxidation increases the complexity of the fretting corrosion behavior of tin plated contacts.

  10. Sliding Wear and Fretting Wear of DLC-Based, Functionally Graded Nanocomposite Coatings

    Science.gov (United States)

    Miyoshi, K.; Pohlchuck, B.; Street, Kenneth W.; Zabinski, J. S.; Sanders, J. H.; Voevodin, A. a.; Wu, R. L. C.

    1999-01-01

    Improving the tribological functionality of diamondlike carbon (DLC) films--developing, good wear resistance, low friction, and high load-carrying capacity-was the aim of this investigation. Nanocomposite coatings consisting of an amorphous DLC (a-DLC) top layer and a functionally graded titanium-titanium carbon-diamondlike carbon (Ti-Ti(sub x) C(sub y)-DLC) underlayer were produced on AISI 440C stainless steel substrates by the hybrid technique of magnetron sputtering and pulsed-laser deposition. The resultant DLC films were characterized by Raman spectroscopy, scanning electron microscopy, and surface profilometry. Two types of wear experiment were conducted in this investioation: sliding friction experiments and fretting wear experiments. Unidirectional ball-on-disk sliding friction experiments were conducted to examine the wear behavior of an a-DLC/Ti-Ti(sub x) C(sub y)-DLC-coated AISI 440C stainless steel disk in sliding contact with a 6-mm-diameter AISI 440C stainless steel ball in ultrahigh vacuum, dry nitrogen, and humid air. Although the wear rates for both the coating and ball were low in all three environments, the humid air and dry nitrogen caused mild wear with burnishing, in the a-DLC top layer, and the ultrahigh vacuum caused relatively severe wear with brittle fracture in both the a-DLC top layer and the Ti-Ti(sub x) C(sub y)-DLC underlayer. For reference, amorphous hydrogenated carbon (H-DLC) films produced on a-DLC/Ti-Ti(sub x) C(sub y)-DLC nanocomposite coatings by using an ion beam were also examined in the same manner. The H-DLC films markedly reduced friction even in ultrahigh vacuum without sacrificing wear resistance. The H-DLC films behaved much like the a-DLC/Ti-Ti(sub x) C(sub y)-DLC nanocomposite coating in dry nitrogen and humid air, presenting low friction and low wear. Fretting wear experiments were conducted in humid air (approximately 50% relative humidity) at a frequency of 80 Hz and an amplitude of 75 micron on an a

  11. Interference Assembly and Fretting Wear Analysis of Hollow Shaft

    Directory of Open Access Journals (Sweden)

    Chuanjun Han

    2014-01-01

    Full Text Available Fretting damage phenomenon often appears in the interference fit assembly. The finite element model of hollow shaft and shaft sleeve was established, and the equivalent stress and contact stress were computed after interference assembly. The assembly body of hollow shaft and shaft sleeve was in whirling bending load, and the contact status (sticking, sliding, and opening and the distribution of stress along one typical contact line were computed under different loads, interferences, hollow degrees, friction coefficient, and wear quantity. Judgment formula of contact state was fixed by introducing the corrected coefficient k. The computation results showed that the “edge effect” appears in the contact surface after interference fit. The size of slip zone is unchanged along with the increase of bending load. The greater the interference value, the bigger the wear range. The hollow degree does not influence the size of stick zone but controls the position of the junction point of slip-open. Tangential contact stress increases with the friction coefficient, which has a little effect on normal contact stress. The relationship between open size and wear capacity is approximately linear.

  12. Fretting wear damage of HexTOOL{sup TM} composite depending on the different fibre orientations

    Energy Technology Data Exchange (ETDEWEB)

    Terekhina, S; Salvia, M; Fouvry, S [Laboratoire de Tribologie et Dynamique des Systemes, UMR CNRS ECL ENISE ENSMSE 5513, Ecole Centrale de Lyon, 69134 Ecully cedex (France); Malysheva, G; Tarasova, T, E-mail: svetlana.terekhina@ec-lyon.fr, E-mail: svetlanaterekhina@yandex.ru [Bauman Moscow State Technical University, 105005 Moscow, 5, 2nd Baumanskaya str (Russian Federation)

    2009-09-15

    The composites have drawn considerable interest in the mould processes. The vibrations and fatigue stresses induced in the moulds made evident to characterize the composite HexTOOL{sup TM} under fretting conditions. Fretting is a small-amplitude oscillatory motion between contacting surfaces. The running conditions fretting maps (RCFM) of composite at ambient conditions were established. The influence of different fiber orientations of HexTOOL{sup TM} composite on the wear kinetics was shown. An energy wear approach was developed. According to results of dynamic mechanical analysis (DMA), the viscoelastic properties of composite material were obtained.

  13. Influence of thermal oxidation duration on the microstructure and fretting wear behavior of Ti6Al4V alloy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Song [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Liao, Zhenhua [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Liu, Yuhong [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Liu, Weiqiang, E-mail: weiqliu@hotmail.com [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China)

    2015-06-01

    Thermal oxidation under water oxidizing atmosphere was performed on Ti6Al4V alloy under different durations from 2 h to 8 h. Surface characterizations were performed using X-ray diffractometery (XRD), scanning electron microscopy (SEM), Raman spectroscopy, nanoindentation and nano scratch testing. Fretting wear behaviors of untreated and oxidized samples were also examined. The formed oxide coating mainly included rutile TiO{sub 2} as well as a little alumina. The weight gain with respect to the oxidation duration obeyed the linear oxidation kinetics law. The growth of oxide grains was in inadequate growth state of incomplete scale coverage from 2nd to 4th hour duration, in normal growth state from 4th to 6th hour duration while in excessive growth state of oxide particle agglomeration and surface roughening from 6th to 8th (or more than 8th) hour duration. The coating thickness increased from 5 μm to 12 μm as oxidation duration increased from 2 h to 8 h. The increase in duration also increased surface roughness and nano hardness as well as adhesion strength of the film/substrate for oxidized samples. The nano hardness value was 10.06 ± 2.15 GPa and the critical load of failure during nano scratch testing was 554.3 ± 6.44 mN for 4 h treated sample. The untreated and oxidized samples showed a same fretting running status and fretting regime with a displacement amplitude of 200 μm while revealing different fretting failure mechanisms. It was mainly abrasive and adhesive wear under ploughing force for untreated sample, while a mix of 3-body abrasion by rolling oxide particles and severe plastic deformation under high contact stress between two ceramic materials for the oxidized samples. The oxide coating was not worn out and improved the fretting wear resistance of titanium alloy. - Highlights: • A thickness of 5–12 μm rutile TiO{sub 2} coating formed under different oxidation durations. • Weight gain with respect to oxidation duration obeyed linear

  14. Cold-Sprayed Cu-MoS2 and Its Fretting Wear Behavior

    Science.gov (United States)

    Zhang, Yinyin; Descartes, Sylvie; Vo, Phuong; Chromik, Richard R.

    2016-02-01

    Cu and Cu-MoS2 coatings were fabricated by cold spray, and the fretting wear performance of the two coatings was compared. A mixture (95 wt.% Cu + 5 wt.% MoS2) was used as feedstock for the composite coating. Coatings were sprayed with identical gas flow conditions on the substrates pre-heated to approximately 170 °C. The morphology of coating top surface and polished cross sections was analyzed by scanning electron microscopy (SEM) and light optical microscopy (LOM). The influence of MoS2 on Cu deposition was examined. The local MoS2 concentration within the coating was found to affect the hardness. Fretting tests were carried out at two different normal loads, and the influence of MoS2 on friction and wear was studied. The morphology and elemental compositions of the wear scars and wear debris were observed by SEM and energy dispersive x-ray spectroscopy (EDS), respectively.

  15. Interference Assembly and Fretting Wear Analysis of Hollow Shaft

    OpenAIRE

    Chuanjun Han; Jie Zhang

    2014-01-01

    Fretting damage phenomenon often appears in the interference fit assembly. The finite element model of hollow shaft and shaft sleeve was established, and the equivalent stress and contact stress were computed after interference assembly. The assembly body of hollow shaft and shaft sleeve was in whirling bending load, and the contact status (sticking, sliding, and opening) and the distribution of stress along one typical contact line were computed under different loads, interferences, hollow d...

  16. Titanium carbide nanoparticles reinforcing nickel matrix for improving nanohardness and fretting wear properties in wet conditions

    Science.gov (United States)

    Dănăilă, Eliza; Benea, Lidia; Caron, Nadège; Raquet, Olivier

    2016-09-01

    In this study Ni/nano-TiC functional composite coatings were produced by electro-codeposition of TiC nanoparticles (50 nm mean diameter) with nickel on 304L stainless steel support. Coatings were obtained from a Watts classical solution in which TiC nanoparticles were added. The surface morphology, chemical composition, structure, roughness and thickness, were evaluated in relation to the effect of TiC nanoparticles incorporation into Ni matrix. It was found that incorporation of TiC nanoparticles into the nickel matrix produces morphological changes in the deposit and increases the roughness. The fretting wear behavior in wet conditions of the obtained coatings was evaluated on a ball-on-plate configuration. To evaluate the wet fretting wear (tribocorrosion) behavior the open circuit potential was measured before, during and after the fretting tests at room temperature in the solution that simulates the primary water circuit of Pressurized Water Reactors. The results show that Ni/nano-TiC composite coatings exhibited a low friction coefficient, high nanohardness and fretting wear resistance in wet conditions compared with pure Ni coatings.

  17. Modeling of Complex Wear Behavior Associated with Grid-to-Rod Fretting in Light Water Nuclear Reactors

    Science.gov (United States)

    Blau, P. J.; Qu, J.; Lu, R.

    2016-09-01

    Fretting wear damage to fuel cladding from flow-induced vibrations can be a significant concern in the operation of light water nuclear reactors. For years, research on the grid-to-rod fretting (GTRF) phenomena has been underway in countries where nuclear power production is a significant industry. Under the auspices of the U.S. Department of Energy Consortium for Advanced Simulation of Light Water Reactors, an effort has been underway to develop and test an engineering wear model for zirconium alloy fuel rod cladding against a supporting grid. The multi-stage model accounts for oxide layers and wear rate transitions. This paper describes the basis for a GTRF engineering wear model, the physical significance of the wear factor it contains, and recent progress toward model validation based on a fretting wear testing apparatus that accounts for coolant temperature, pressure, and the presence of periodic impacts (gaps) in grid/rod contact.

  18. Modeling of Complex Wear Behavior Associated with Grid-to-Rod Fretting in Light Water Nuclear Reactors

    Science.gov (United States)

    Blau, P. J.; Qu, J.; Lu, R.

    2016-11-01

    Fretting wear damage to fuel cladding from flow-induced vibrations can be a significant concern in the operation of light water nuclear reactors. For years, research on the grid-to-rod fretting (GTRF) phenomena has been underway in countries where nuclear power production is a significant industry. Under the auspices of the U.S. Department of Energy Consortium for Advanced Simulation of Light Water Reactors, an effort has been underway to develop and test an engineering wear model for zirconium alloy fuel rod cladding against a supporting grid. The multi-stage model accounts for oxide layers and wear rate transitions. This paper describes the basis for a GTRF engineering wear model, the physical significance of the wear factor it contains, and recent progress toward model validation based on a fretting wear testing apparatus that accounts for coolant temperature, pressure, and the presence of periodic impacts (gaps) in grid/rod contact.

  19. Design improvement for fretting-wear reduction of HANARO fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yeong Garp; Chae, H. T.; Ryu, J. S.; Kim, H. R

    2000-06-01

    In the course of the visual inspection of the fuel assemblies un-loaded from the reactor core in December 1996, it was observed that many of fuel assemblies had mechanical damages on some components. The major damage was the freting-wear on spacer plates and endplates due to the flow induced vibration of the fuel assembly in the flow tube. Since the reactor is activated and the system modification for complete removal of the driving factors of the vibration of fuel assemblies is practically very difficult, the focus has been on the design change of the fuel assemblies. Consequently, various design changes were proposed to strengthen the wear resistance of the components based on the evaluation of the visual inspection results. The validity of the proposals was verified through the performance tests for the modified components, and the vibration test and endurance test for the fuel assemblies using the single-channel test rig(SCTR) in AECL.The subsequent design changes were additionally proposed based on the visual inspections for the fuel assemblies that had been fabricated according to the first design change and loaded in the core. As the effects of the first design change, the fretting-wear of spacer plates was remarkably reduced and the period until fretting-wear damage was extended by 60% for the first modified 36-rod fuel assembly. It is too early to say the endurance life time for the first modified 18-rod fuel assembly because of insufficient statistical data of only two bundles damaged, but the fretting-wear at the bottom endplate slot was reduced to about 50%. The second modified fuel assemblies, that were not loaded into the core yet, are expected to meet the design requirements for the core residence time due to strengthening the weak parts from the fretting-wear point of view. This report describes design changes and tests for fuel assemblies of HANARO to reduce the fretting-wear, and estimates the effects of design improvement quantitatively compared

  20. An all-in-one numerical methodology for fretting wear and fatigue life assessment

    Directory of Open Access Journals (Sweden)

    I. Llavori

    2016-07-01

    Full Text Available Many mechanical components such as, bearing housings, flexible couplings and spines or orthopedic devices are simultaneously subjected to a fretting wear and fatigue damage. For this reason, the combined study on a single model of wear, crack initiation and propagation is of great interest. This paper presents an all-in-one 2D cylinder on flat numerical model for life assessment on coupled fretting wear and fatigue phenomena. In the literature, two stages are usually distinguished: crack nucleation and its subsequent growth. The method combines the Archard wear model, a critical-plane implementation of the Smith-Watson- Topper (SWT multiaxial fatigue criterion coupled with the Miner-Palmgren accumulation damage rule for crack initiation prediction. Then, the Linear Elastic Fracture Mechanics (LEFM via eXtended Finite Element Method (X-FEM embedded into the commercial finite element code Abaqus FEA has been employed to determine the crack propagation stage. Therefore, the sum of the two stages gives a total life prediction. Finally, the numerical model was validated with experimental data reported in the literature and a good agreement was obtained.

  1. The effect of plasma nitriding and post oxidation on fretting wear behaviour of a high strength alloy steel

    Science.gov (United States)

    Prakash, N. Arun; Bennett, C. J.

    2017-05-01

    The fretting wear performance of the non-nitrided, nitrided and nitrided-post oxidized high strength alloy steel, W460 were investigated in the gross slip regime at ambient condition. Fretting wear tests were performed with an applied normal load of 250 and 650 N at a displacement amplitude of 100 μm using a cylinder-on-flat configuration. X-ray analysis (XRD) revealed the formation of the iron-nitrided Fe3N and Fe4N during plasma nitriding and iron oxide phases of hematite (Fe2O3) and magnetite (Fe3O4) during post-oxidation of the cylindrical steel samples. The steady state tangential force coefficient decreases when the nitrided and post-oxidized samples were fretted against the non-nitrided steel material when compared to the non-nitrided steel contact pair. The steady state tangential force coefficient decreased with an increase in applied normal load across all of the fretting conditions. The total dissipated energy and the total wear volume increased with an increase in applied normal load with total wear volume of the non-nitrided vs nitrided and non-nitrided vs nitrided post-oxidized sample pairs, showing a reduction in the wear volume of approximately 50% compared to the non-nitrided vs non-nitrided combination under the fretting conditions examined. The worn surface morphology of the fretted samples examined using a scanning electron microscope showed the presence of loose wear debris in the wear track, fragmented wear debris, delamination cracks, delamination with large discontinuities, plate-like wear debris, oxide patches and formation of large cavities.

  2. Advanced non-linear flow-induced vibration and fretting-wear analysis capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Toorani, M.; Pan, L.; Li, R.; Idvorian, N. [Babcock and Wilcox Canada Ltd., Cambridge, Ontario (Canada); Vincent, B.

    2009-07-01

    Fretting wear is a potentially significant degradation mechanism in nuclear steam generators and other shell and tube heat transfer equipment as well. This paper presents an overview of the recently developed code FIVDYNA which is used for the non-linear flow-induced vibration and fretting wear analysis for operating steam generators (OTSG and RSG) and shell-and-tube heat exchangers. FIVDYNA is a non-linear time-history Flow-Induced Vibration (FIV) analysis computer program that has been developed by Babcock and Wilcox Canada to advance the understanding of tube vibration and tube to tube-support interaction. In addition to the dynamic fluid induced forces the program takes into account other tube static forces due to axial and lateral tube preload and thermal interaction loads. The program is capable of predicting the location where the fretting wear is most likely to occur and its magnitude taking into account the support geometry including gaps. FIVDYNA uses the general purpose finite element computer code ABAQUS as its solver. Using ABAQUS gives the user the flexibility to add additional forces to the tube ranging from tube preloads and the support offsets to thermal loads. The forces currently being modeled in FIVDYNA are the random turbulence, steady drag force, fluid-elastic forces, support offset and pre-strain force (axial loads). This program models the vibration of tubes and calculates the structural dynamic characteristics, and interaction forces between the tube and the tube supports. These interaction forces are then used to calculate the work rate at the support and eventually the predicted depth of wear scar on the tube. A very good agreement is found with experiments and also other computer codes. (author)

  3. Effect of frequency on fretting wear behavior of Ti/TiN multilayer film on depleted uranium.

    Science.gov (United States)

    Wu, Yan-Ping; Li, Zheng-Yang; Zhu, Sheng-Fa; Lu, Lei; Cai, Zhen-Bing

    2017-01-01

    The Ti/TiN multi-layer film was prepared on the depleted uranium (DU) substrate by cathodic arc ion plating equipment. The character of multi-layer film was studied by SEM, XRD and AES, revealed that the surface was composed of small compact particle and the cross-section had a multi-layer structure. The fretting wear performance under different frequencies was performed by a MFT-6000 machine with a ball-on-plate configuration. The wear morphology was analyzed by white light interferometer, OM and SEM with an EDX. The result shows the Ti/TiN multi-layer film could greatly improve the fretting wear performance compared to the DU substrate. The fretting wear running and damaged behavior are strongly dependent on the film and test frequency. The fretting region of DU substrate and Ti/TiN multi-layer under low test frequency is gross slip. With the increase of test frequency, the fretting region of Ti/TiN multi-layer change from gross slip to mixed fretting, then to partial slip.

  4. Fretting wear behavior of Cr-coated fuel rod for accident-tolerant fuel in flowing fluid

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Ho; Kim, Hyung Kyu; Kim, Hyun Gil; Koo, Yang Hyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Fretting wear test of the Cr-coated fuel clading candidate have been performed in the flowing fluid condition in order to verify the reliability of Cr-coated layer on zirconium-based fuel cladding. Rod wear volume at each grid spring and dimple is dramaically increased with GTR gap even though each wear scar is not evenly distributed within a 1x1 grid cell.

  5. Fretting Wear Behavior of Medium Carbon Steel Modified by Low Temperature Gas Multi-component Thermo-chemical Treatment

    Institute of Scientific and Technical Information of China (English)

    LUO Jun; ZHENG Jianfeng; PENG Jinfang; HE Liping; ZHU Minhao

    2010-01-01

    The introduction of surface engineering is expected to be an effective strategy against fretting damage. A large number of studies show that the low gas multi-component (such as carbon, nitrogen, sulphur and oxygen, etc) thermo-chemical treatment(LTGMTT) can overcome the brittleness of nitriding process, and upgrade the surface hardness and improve the wear resistance and fatigue properties of the work-pieces significantly. However, there are few reports on the anti-fretting properties of the LTGMTT modified layer up to now, which limits the applications of fretting. So this paper discusses the fretting wear behavior of modified layer on the surface of LZ50 (0.48%C) steel prepared by low temperature gas multi-component thermo-chemical treatment (LTGMTT) technology. The fretting wear tests of the modified layer flat specimens and its substrate (LZ50 steel) against 52100 steel balls with diameter of 40 mm are carried out under normal load of 150 N and displacement amplitudes varied from 2 μm to 40 μm. Characterization of the modified layer and dynamic analyses in combination with microscopic examinations were performed through the means of scanning electron microscope(SEM), optical microscope(OM), X-ray diffraction(XRD) and surface profilometer. The experimental results showed that the modified layer with a total thickness of 60 μm was consisted of three parts, i.e., loose layer, compound layer and diffusion layer. Compared with the substrate, the range of the mixed fretting regime(MFR) of the LTGMTT modified layer diminished, and the slip regime(SR) of the modified layer shifted to the direction of smaller displacement amplitude. The coefficient of friction(COF) of the modified layer was lower than that of the substrate in the initial stage. For the modified layer, the damage in partial slip regime(PSR) was very slight. The fretting wear mechanism of the modified layer both in MFR and SR was abrasive wear and delamination. The modified layer presented better wear

  6. Study on torsional fretting wear behavior of a ball-on-socket contact configuration simulating an artificial cervical disk

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Song [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Wang, Fei [School of Material Science and Engineering, China University of Mining and Technology, Xuzhou 221116 (China); Liao, Zhenhua [Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); Wang, Qingliang [School of Material Science and Engineering, China University of Mining and Technology, Xuzhou 221116 (China); Liu, Yuhong [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China); Department of Mechanical Engineering, Tsinghua University, Beijing 100084 (China); Liu, Weiqiang, E-mail: weiqliu@hotmail.com [Biomechanics and Biotechnology Lab, Research Institute of Tsinghua University in Shenzhen, Shenzhen 518057 (China); State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China)

    2015-10-01

    A ball-on-socket contact configuration was designed to simulate an artificial cervical disk in structure. UHMWPE (ultra high molecular weight polyethylene) hot pressed by powders and Ti6Al4V alloy were selected as the material combination of ball and socket. The socket surface was coated by a ~ 500 nm C-DLC (carbon ion implantation-diamond like carbon) mixed layer to improve its surface nano hardness and wear resistance. The torsional fretting wear behavior of the ball-on-socket model was tested at different angular displacements under 25% bovine serum lubrication with an axial force of 100 N to obtain more realistic results with that in vivo. The fretting running regimes and wear damage characteristics as well as wear mechanisms for both ball and socket were studied based on 2D (two dimension) optical microscope, SEM (scanning electron microscope) and 3D (three dimension) profiles. With the increase of angular displacement amplitude from 1° to 7°, three types of T-θ (Torsional torque-angular displacement amplitude) curves (i.e., linear, elliptical and parallelogram loops) corresponding to running regimes of PSR (partial slip regime), MR (mixed regime) and SR (slip regime) were observed and analyzed. Both the central region and the edge zone of the ball and socket were damaged. The worn surfaces were characterized by wear scratches and wear debris. In addition, more severe wear damage and more wear debris appeared on the central region of the socket at higher angular displacement amplitude. The dominant damage mechanism was a mix of surface scratch, adhesive wear and abrasive wear for the UHMWPE ball while that for the coated socket was abrasive wear by PE particles and some polishing and rolling process on the raised overgrown DLC grains. The frictional kinetic behavior, wear type, damage region and damage mechanism for the ball-on-socket model revealed significant differences with those of a ball-on-flat contact while showing better consistency with that of in

  7. Friction and wear properties of high-velocity oxygen fuel sprayed WC-17Co coating under rotational fretting conditions

    Science.gov (United States)

    Luo, Jun; Cai, Zhenbing; Mo, Jiliang; Peng, Jinfang; Zhu, Minhao

    2016-05-01

    Rotational fretting which exist in many engineering applications has incurred enormous economic loss. Thus, accessible methods are urgently needed to alleviate or eliminate damage by rotational fretting. Surface engineering is an effective approach that is successfully adopted to enhance the ability of components to resist the fretting damage. In this paper, using a high-velocity oxygen fuel sprayed (HVOF) technique WC-17Co coating is deposited on an LZ50 steel surface to study its properties through Vickers hardness testing, scanning electric microscope (SEM), energy dispersive X-ray spectroscopy (EDX), and X-ray diffractrometry (XRD). Rotational fretting wear tests are conducted under normal load varied from 10 N to 50 N, and angular displacement amplitudes vary from 0.125° to 1°. Wear scars are examined using SEM, EDX, optical microscopy (OM), and surface topography. The experimental results reveal that the WC-17Co coating adjusted the boundary between the partial slip regime (PSR) and the slip regime (SR) to the direction of smaller amplitude displacement. As a result, the coefficients of friction are consistently lower than the substrate's coefficients of friction both in the PSR and SR. The damage to the coating in the PSR is very slight. In the SR, the coating exhibits higher debris removal efficiency and load-carrying capacity. The bulge is not found for the coating due to the coating's higher hardness to restrain plastic flow. This research could provide experimental bases for promoting industrial application of WC-17Co coating in prevention of rotational fretting wear.

  8. Study on torsional fretting wear behavior of a ball-on-socket contact configuration simulating an artificial cervical disk.

    Science.gov (United States)

    Wang, Song; Wang, Fei; Liao, Zhenhua; Wang, Qingliang; Liu, Yuhong; Liu, Weiqiang

    2015-10-01

    A ball-on-socket contact configuration was designed to simulate an artificial cervical disk in structure. UHMWPE (ultra high molecular weight polyethylene) hot pressed by powders and Ti6Al4V alloy were selected as the material combination of ball and socket. The socket surface was coated by a ~500 nm C-DLC (carbon ion implantation-diamond like carbon) mixed layer to improve its surface nano hardness and wear resistance. The torsional fretting wear behavior of the ball-on-socket model was tested at different angular displacements under 25% bovine serum lubrication with an axial force of 100 N to obtain more realistic results with that in vivo. The fretting running regimes and wear damage characteristics as well as wear mechanisms for both ball and socket were studied based on 2D (two dimension) optical microscope, SEM (scanning electron microscope) and 3D (three dimension) profiles. With the increase of angular displacement amplitude from 1° to 7°, three types of T-θ (Torsional torque-angular displacement amplitude) curves (i.e., linear, elliptical and parallelogram loops) corresponding to running regimes of PSR (partial slip regime), MR (mixed regime) and SR (slip regime) were observed and analyzed. Both the central region and the edge zone of the ball and socket were damaged. The worn surfaces were characterized by wear scratches and wear debris. In addition, more severe wear damage and more wear debris appeared on the central region of the socket at higher angular displacement amplitude. The dominant damage mechanism was a mix of surface scratch, adhesive wear and abrasive wear for the UHMWPE ball while that for the coated socket was abrasive wear by PE particles and some polishing and rolling process on the raised overgrown DLC grains. The frictional kinetic behavior, wear type, damage region and damage mechanism for the ball-on-socket model revealed significant differences with those of a ball-on-flat contact while showing better consistency with that of in

  9. Effects of Plasma ZrN Metallurgy and Shot Peening Duplex Treatment on Fretting Wear and Fretting Fatigue Behavior of Ti6Al4V Alloy

    Directory of Open Access Journals (Sweden)

    Jingang Tang

    2016-03-01

    Full Text Available A metallurgical zirconium nitride (ZrN layer was fabricated using glow metallurgy using nitriding with zirconiuming prior treatment of the Ti6Al4V alloy. The microstructure, composition and microhardness of the corresponding layer were studied. The influence of this treatment on fretting wear (FW and fretting fatigue (FF behavior of the Ti6Al4V alloy was studied. The composite layer consisted of an 8-μm-thick ZrN compound layer and a 50-μm-thick nitrogen-rich Zr–Ti solid solution layer. The surface microhardness of the composite layer is 1775 HK0.1. A gradient in cross-sectional microhardness distribution exists in the layer. The plasma ZrN metallurgical layer improves the FW resistance of the Ti6Al4V alloy, but reduces the base FF resistance. This occurs because the improvement in surface hardness results in lowering of the toughness and increasing in the notch sensitivity. Compared with shot peening treatment, plasma ZrN metallurgy and shot peening composite treatment improves the FW resistance and enhances the FF resistance of the Ti6Al4V alloy. This is attributed to the introduction of a compressive stress field. The combination of toughness, strength, FW resistance and fatigue resistance enhance the FF resistance for titanium alloy.

  10. Effects of Plasma ZrN Metallurgy and Shot Peening Duplex Treatment on Fretting Wear and Fretting Fatigue Behavior of Ti6Al4V Alloy.

    Science.gov (United States)

    Tang, Jingang; Liu, Daoxin; Zhang, Xiaohua; Du, Dongxing; Yu, Shouming

    2016-03-23

    A metallurgical zirconium nitride (ZrN) layer was fabricated using glow metallurgy using nitriding with zirconiuming prior treatment of the Ti6Al4V alloy. The microstructure, composition and microhardness of the corresponding layer were studied. The influence of this treatment on fretting wear (FW) and fretting fatigue (FF) behavior of the Ti6Al4V alloy was studied. The composite layer consisted of an 8-μm-thick ZrN compound layer and a 50-μm-thick nitrogen-rich Zr-Ti solid solution layer. The surface microhardness of the composite layer is 1775 HK0.1. A gradient in cross-sectional microhardness distribution exists in the layer. The plasma ZrN metallurgical layer improves the FW resistance of the Ti6Al4V alloy, but reduces the base FF resistance. This occurs because the improvement in surface hardness results in lowering of the toughness and increasing in the notch sensitivity. Compared with shot peening treatment, plasma ZrN metallurgy and shot peening composite treatment improves the FW resistance and enhances the FF resistance of the Ti6Al4V alloy. This is attributed to the introduction of a compressive stress field. The combination of toughness, strength, FW resistance and fatigue resistance enhance the FF resistance for titanium alloy.

  11. Processing, Characterization and Fretting Wear of Zinc Oxide and Silver Nanoparticles Reinforced Ultra High Molecular Weight Polyethylene Biopolymer Nanocomposite

    Science.gov (United States)

    Alam, Fahad; Kumar, Anil; Patel, Anup Kumar; Sharma, Rajeev K.; Balani, Kantesh

    2015-04-01

    Ultra-high molecular weight polyethylene (UHMWPE) is the most widely used biopolymer for articulating surfaces, such as an acetabular cup liner interfacing with a metal/ceramic femoral head. However, the formation of wear debris leads to the aseptic loosening of implants. Thus, in order to improve the life span via enhancing the fretting wear resistance, UHMWPE is reinforced with ZnO/Ag nanoparticles. It is envisaged that the ZnO/Ag addition will also exhibit antibacterial properties. In the current study, the synergetic effect of the reinforcement of ZnO/Ag nanoparticles (0-3 wt.% combinations) on the fretting wear behavior of a UHMWPE matrix is assessed. The phase characterization of compression- molded UHMWPE-Ag-ZnO biopolymer nanocomposites has elicited the retention of starting phases. All samples were processed at >98% density using compression molding. Silver and ZnO reinforcement showed enhanced hardness ~20.4% for U3A and 42.0% for U3Z. Fretting wear performance was evaluated at varying loads (5-15 N), keeping in mind the weight at different joints, with constant frequency (5 Hz) as well as amplitude of oscillation (100 µm). Laser surface profilometry showed change of wear volume from 8.6 × 10-5 mm3 for neat polymer to 5.8 × 10-5 mm3 with 1 wt.% Ag + 1 wt.% ZnO reinforcement (at 15 N load). Consequently, the mechanics of resistance offered by Ag and ZnO is delineated in the UHMWPE matrix. Further, S. aureus viability reduction is ~28.7% in cases with 1 wt.% Ag addition, ~42.5% with 1 wt.% ZnO addition, but synergistically increase to ~58.6% and 47.1% when each of Ag and ZnO is added with 1 wt.% and 3 wt.%, respectively (when compared to that of the UHMWPE control sample). Increased wear resistance and superior bioactivity and enhanced anti-bacterial properties of 1 wt.% Ag + 1 wt.% ZnO and 3 wt.% Ag + 3 wt.% ZnO shows the potential use of ZnO-Ag-UHMWPE biopolymer composites as an articulating surface.

  12. Fretting wear in titanium, Monel-400, and cobalt 25-percent-molybdenum using scanning electron microscopy

    Science.gov (United States)

    Bill, R. C.

    1972-01-01

    Damage scar volume measurements taken from like metal fretting pairs combined with scanning electron microscopy observations showed that three sequentially operating mechanisms result in the fretting of titanium, Monel-400, and cobalt - 25-percent molybdenum. Initially, adhesion and plastic deformation of the surface played an important role. This was followed after a few hundred cycles by a fatigue mechanism which produced spall-like pits in the damage scar. Finally, a combination of oxidation and abrasion by debris particles became most significant. Damage scar measurements made on several elemental metals after 600,000 fretting cycles suggested that the ratio of oxide hardness to metal hardness was a measure of the susceptibility of a metal to progressive damage by fretting.

  13. Dual Time Stepping Algorithms With the High Order Harmonic Balance Method for Contact Interfaces With Fretting-Wear

    CERN Document Server

    Salles, Loic; Gouskov, Alexandre; Jean, Pierrick; Thouverez, Fabrice

    2014-01-01

    Contact interfaces with dry friction are frequently used in turbomachinery. Dry friction damping produced by the sliding surfaces of these interfaces reduces the amplitude of bladed-disk vibration. The relative displacements at these interfaces lead to fretting-wear which reduces the average life expectancy of the structure. Frequency response functions are calculated numerically by using the multi-harmonic balance method (mHBM). The dynamic Lagrangian frequency-time method is used to calculate contact forces in the frequency domain. A new strategy for solving nonlinear systems based on dual time stepping is applied. This method is faster than using Newton solvers. It was used successfully for solving Nonlinear CFD equations in the frequency domain. This new approach allows identifying the steady state of worn systems by integrating wear rate equations a on dual time scale. The dual time equations are integrated by an implicit scheme. Of the different orders tested, the first order scheme provided the best re...

  14. Evaluation of fretting failures on PWR fuel by post-irradiation examinations and modeling in the DEGRAD-1 code

    Energy Technology Data Exchange (ETDEWEB)

    Castanheira, Myrthes; Silva, Jose Eduardo Rosa da; Lucki, Georgi; Terremoto, Luis A.A.; Silva, Antonio Teixeira e; Teodoro, Celso A.; Damy, Margaret de A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: myrthes@ipen.br

    2007-07-01

    One of the major recognized causes of fuel rod failures is fretting of the clad due to the entrapment of debris in a fuel rod spacer. Such debris, inadvertently dropped into the primary system during maintenance operations, includes various sizes of particles. Intermediate size particles, such as metal cuttings, electrical connectors, metal fittings, pieces of wire, and small nuts and bolts can become trapped between fuel rods in a spacer where hydraulically induced vibrations can cause fretting failure of the fuel rod. An evaluation of debris fretting failure on PWR fuel is presented. The inquiries on fuel rods failures are based on results of analysis using post-irradiation non-destructive examination. The complementary analysis includes a modeling approach by code DEGRAD-1 to characterize the degradation phenomenon after primary failure integrated in the reactor operational history. (author)

  15. Fretting wear behavior of laser-nitrided Ti-5Al-5Mo-5V-1Cr-1Fe alloy fabricated by laser melting deposition

    Science.gov (United States)

    Liu, L.; Shangguan, Y. J.; Tang, H. B.; Wang, H. M.

    2014-09-01

    Fretting wear behavior of laser-nitrided titanium alloy (Ti-5Al-5Mo-5V-1Cr-1Fe) fabricated by laser melting deposition (LMD) has been investigated to explore surface engineering for protection against wear damage of laser melting deposited titanium alloy. The morphology and volume of the wear scars of unmodified and laser-nitrided LMD Ti-5Al-5Mo-5V-1Cr-1Fe tested at different frequencies, 10 and 50 Hz, were studied using non-contact three-dimensional surface profilometer and scanning electron microscope. Friction coefficients measured at different frequencies or loading forces were compared for unmodified and laser-nitrided LMD specimens. Experimental results show that laser-nitrided LMD specimens have shown fretting resistance superior to unmodified LMD specimens due to the presence of hard TiN dendrites in the laser-nitrided layer. W-shaped wear scar caused by local rotation of fretting ball at the two ends of the scar was observed. Given a constant loading force of 50 N, unmodified and laser-nitrided LMD specimens exhibited similar friction coefficients and their friction coefficients increased with test frequency. The friction coefficients of both specimens increased with the reduction of normal load, which corresponds to the trend in Hertzian contact model.

  16. The roles of contact conformity, temperature and displacement amplitude on the lubricated fretting wear of a steel-on-steel contact

    Science.gov (United States)

    Warmuth, A. R.; Sun, W.; Shipway, P. H.

    2016-10-01

    This paper investigates the effect of contact geometry, temperature and displacement amplitude on the fretting behaviour of an aero-turbo oil lubricated cylinder-on-flat contact. To be effective, the lubricant needed both to penetrate the contact and then offer protection. Lubricant penetration into the fretting contact is found to be controlled by two physical parameters, namely (i) the width of the contact that remains covered throughout the fretting test and (ii) the lubricant viscosity. The protection offered by the lubricant (assuming that it has successfully penetrated the contact) is influenced by four physical parameters, namely (i) lubricant viscosity, (ii) traverse velocity, (iii) nominal contact pressure, and (iv) chemical effects. The relationship between the three experimental parameters which were varied in the programme of work (temperature, fretting displacement and cylinder radius) and physical parameters which influence the protection offered by the lubricant film can be competing, and therefore complex wear behaviour is observed. The roles of the various parameters in controlling the wear behaviour are presented in a coherent physical framework.

  17. Effects of the different frequencies and loads of ultrasonic surface rolling on surface mechanical properties and fretting wear resistance of HIP Ti-6Al-4V alloy

    Science.gov (United States)

    Li, G.; Qu, S. G.; Pan, Y. X.; Li, X. Q.

    2016-12-01

    The main purpose of this paper was to investigate the effects of the different frequencies and loads of multi-pass ultrasonic surface rolling (MUSR) on surface layer mechanical properties, microstructure and fretting friction and wear characteristics of HIP (hot isostatic pressing) Ti-6Al-4 V alloy. Some microscopic analysis methods (SEM, TEM and EDS) were used to characterize the modified surface layer of material after MUSR treatment. The results indicated that the material in sample surface layer experienced a certain extent plastic deformation, and accompanied by some dense dislocations and twins generation. Moreover surface microhardness and residual stress of samples treated by MUSR were also greatly improved compared with the untreated. The fretting friction and wear properties of samples treated by MUSR in different conditions are tested at 10 and 15 N in dry friction conditions. It could be found that friction coefficient and wear volume loss were significantly declined in the optimal result. The main wear mechanism of MUSR-treated samples included abrasive wear, adhesion and spalling.

  18. Fretting of AISI 9310 and selected fretting resistant surface treatments

    Science.gov (United States)

    Bill, R. C.

    1977-01-01

    Fretting wear experiments were conducted with uncoated AISI 9310 mating surfaces, and with combinations incorporating a selected coating to one of the mating surfaces. Wear measurements and SEM observations indicated that surface fatigue, as made evident by spallation and surface crack formation, is an important mechanism in promoting fretting wear to uncoated 9310. Increasing humidity resulted in accelerated fretting, and a very noticeable difference in nature of the fretting debris. Of the coatings evaluated, aluminum bronze with a polyester additive was most effective at reducing wear and minimizing fretting damage to the mating uncoated surface, by means of a selflubricating film that developed on the fretting surfaces. Chromium plate performed as an effective protective coating, itself resisting fretting and not accelerating damage to the uncoated surface.

  19. Experimental study on wear failure course of gas-valve/valve-seat in engine

    Institute of Scientific and Technical Information of China (English)

    ZHAO Yun-cai; YAN Hang-zhi

    2005-01-01

    The wear failure course of gas-valve/valve-seat in engine was investigated with a simulating tester. The results show that the failure of the contact conical surface is mainly caused by the elastic and plastic deformation and the fatigue micro-crack and spalling. The creep-deformation and corrosion atmosphere accelerated wear failure course at the high temperature. The wear failure course of the gas-valve/valve-seat in engine follows general wear rules of mechanical elements, but the rate of wear in the sharp wear stage is faster.

  20. Study of fretting wear in titanium, Monel-400, and cobalt-25 percent molybdenum using scanning electron microscopy.

    Science.gov (United States)

    Bill, R. C.

    1973-01-01

    Damage scar volume measurements taken from like metal fretting pairs, combined with scanning electron microscopy observations, showed that three sequentially operating mechanisms result in the fretting of titanium, Monel-400, and cobalt-25% molybdenum. Initially, adhesion and plastic deformation on the surface played an important role. This was followed after a few hundred cycles by a fatigue mechanism, producing spall-like pits in the damage scar. Finally, an oxidation-related mechanism became most significant. Damage scar measurements made on several elemental metals after 600,000 fretting cycles suggested that the ratio of oxide hardness to metal hardness was a measure of the susceptibility of a metal to progressive damage by fretting.

  1. Study of fretting wear in titanium, Monel-400, and cobalt-25 percent molybdenum using scanning electron microscopy.

    Science.gov (United States)

    Bill, R. C.

    1973-01-01

    Damage scar volume measurements taken from like metal fretting pairs, combined with scanning electron microscopy observations, showed that three sequentially operating mechanisms result in the fretting of titanium, Monel-400, and cobalt-25% molybdenum. Initially, adhesion and plastic deformation on the surface played an important role. This was followed after a few hundred cycles by a fatigue mechanism, producing spall-like pits in the damage scar. Finally, an oxidation-related mechanism became most significant. Damage scar measurements made on several elemental metals after 600,000 fretting cycles suggested that the ratio of oxide hardness to metal hardness was a measure of the susceptibility of a metal to progressive damage by fretting.

  2. RUNNING CONDITION FRETTING MAPS OF POLYMER MATERIALS

    Directory of Open Access Journals (Sweden)

    Szilárd Tamás Vezér

    2009-04-01

    Full Text Available Due to the industrial demand, the determination of the wear behaviour of polymeric materials is an important research task. Rubbers and elastomers are used widely in contacts, where wear is the dominant failure mechanisms. Furthermore, only the material properties under large displacements were investigated in the majority of existing studies. Depending on the input physical parameters of the tribological systems small oscillations are also observed on the measured signals (due to stick-slip like effect in the contact zone of the elastomers. To describe the failure behaviour under this special condition, a novel fretting fatigue test system was developed and built on a electro-dynamical shaker in this study. The contact area were defined with some additional test, like 2D full field strain analysis, compression and creep tests. Based on the methodology developed and applied for steels and polymer composites, Running Condition Fretting Maps for two elastomer grades (HNBR and TPU were determined.

  3. Fretting wear behaviour of hydroxyapatite-titanium composites in simulated body fluid, supplemented with 5 g l-1 bovine serum albumin

    Science.gov (United States)

    Kumar, Alok; Biswas, Krishanu; Basu, Bikramjit

    2013-10-01

    Damaged articulating joints can be repaired or replaced with synthetic biomaterials, which can release wear debris due to articulation, leading to the osteolysis. In a recent work, it has been shown that it is possible to achieve a better combination of flexural strength/fracture toughness as well as in vitro bioactivity and cytocompatibility properties in spark plasma sintered hydroxyapatite-titanium (HA-Ti) composites. Although hydroxyapatite and titanium are well documented for their good biocompatibility, nanosized hydroxyapatite (HA) and titanium (Ti) particles can cause severe toxicity to cells. In order to address this issue, fretting wear study of HA-Ti composites under dry and wet (1× SBF, supplemented with 5 g l-1 bovine serum albumin (BSA)) condition was performed to assess the wear resistance as well as wear debris formation, in vitro. The experimental results reveal one order of magnitude lower wear rate for HA-10 wt% Ti (7.5 × 10-5 mm3 N-1 m-1) composite than monolithic HA (3.9 × 10-4 mm3 N-1 m-1) in simulated body fluid. The difference in the tribological properties has been analyzed in the light of phase assemblages and mechanical properties. Overall, the results suggest the potential use of HA-Ti composites over existing HA-based biocomposites in orthopedic as well as dental applications.

  4. Effects of temperature, slip amplitude, contact pressure on fretting fatigue behavior of Ti811 alloys at elevated temperatures

    Institute of Scientific and Technical Information of China (English)

    Xiaohua ZHANG; Daoxin LIU

    2009-01-01

    Effects of the temperature, slip amplitude, and contact pressure on fretting fatigue (FF) behavior of the Ti811 titanium alloy were investigated using a high frequency fatigue machine and a home-made high temperature apparatus. The fretting fatigue failure mechanism was studied by observing the fretting surface morphology features. The results show that the sensitivity to fretting fatigue is high at both 350 and 500 ℃. The higher the temperature, the more sensitive to the fretting fatigue failure is. Creep is an important factor that influences the fretting fatigue failure process at elevated temperatures. The fretting fatigue life of the Ti811 alloy does not change in a monotonic way as the slip amplitude and contact pressure increase. This is owing to the fact that the slip amplitude affects the action of fatigue and wear in the fretting process, and the nominal contact pressure affects the distribution and concentration of the stress and the amplitude of fretting slip at the contact surface, and thus further influences the crack initiation probability and the driving force for propagation.

  5. Fretting Fatigue Experiment and Analysis of AlSi9Cu2Mg Alloy

    Directory of Open Access Journals (Sweden)

    Jun Wang

    2016-12-01

    Full Text Available An investigation was carried out in order to study the fretting fatigue behavior of an AlSi9Cu2Mg aluminum alloy. The fretting fatigue tests of AlSi9Cu2Mg were performed using a specially designed testing machine. The failure mechanism of fretting fatigue was explored by studying the fracture surfaces, fretting scars, fretting debris, and micro-hardness of fretting fatigue specimens using scanning electron microscopy (SEM, energy-dispersive X-ray spectroscopy (EDX, and micro Vickers hardness test techniques. The experimental results show that the fretting fatigue limit (42 MPa is significantly reduced to approximately 47% of the plain fatigue limit (89 MPa under 62.5 MPa contact pressure. Furthermore, the fretting fatigue life decreases with increasing alternating stress and increasing contact pressure. The examination results suggest that the stress concentrates induced by oxidation-assisted wear on the contact interface led to the earlier initiation and propagation of crack under the fretting condition.

  6. Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation.

    Science.gov (United States)

    Ashkanfar, Ariyan; Langton, David J; Joyce, Thomas J

    2017-08-10

    The generation of particulate debris at the taper junction of total hip replacements (THRs), can cause failure of the artificial hip. The taper surfaces of femoral heads and trunnions of femoral stems are generally machined to a certain roughness to enhance fixation. However, the effect of the surface roughness of these surfaces on the fixation, wear and consequently clinical outcomes of the design is largely unknown. In this study, we asked whether a micro-grooved trunnion surface finish (1) improves the fixation and (2) reduces the wear rate at the taper junction of THRs. We used 3D finite element (FE) models of THRs to, firstly, investigate the effect of initial fixation of a Cobalt-Chromium femoral head with a smooth taper surface mated with a Titanium (1) micro-grooved and (2) smooth, trunnion surface finishes. Secondly, we used a computational FE wear model to compare the wear evolution between the models, which was then validated against wear measurements of the taper surface of explanted femoral heads. The fixation at the taper junction was found to be better for the smooth couplings. Over a 7 million load cycle analysis in-silico, the linear wear depth and the total material loss was around 3.2 and 1.4 times higher for the femoral heads mated with micro-grooved trunnions. It was therefore concluded that smooth taper and trunnion surfaces will provide better fixation at the taper junction and reduce the volumetric wear rates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Development of the vibration analysis technique of fuel rod and research on the methodology of fuel fretting wear analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Heung Seok; Kim, Kyung Kyu; Yoon, Hyung Hoo; Song, Ki Nam

    1998-12-01

    The FEM program has been developed to predict the natural frequencies, the FEM program has been developed to predict the natural frequencies, and mode shapes of fuel rod subjected to axial force and continuously supported by a rotational and vent spring system, and to calculate the minimum reaction forces of the spacer grid spring when the maximum vibration amplitude of fuel rod is known. This program has been verified by commercial ANSYS program and the vibration test of dummy rods in air. The test equipment were set to get the fifth modes of test rods. Partial slip problem has been studied for the analysis of fuel fretting problem. Firstly, the assumption of semi-infiniteness of the contact bodies were validated by finite element (FE) analysis. From FE results, a classical bodies were validated by finite element (FE) analysis. From FE results, aclassical theory of elasticity was utilized with regarding the problem as a plane problem. Secondly, the Mindlin-Cattaneo problem was re-evaluated, which gave the fundamental idea for developing the numerical tool for the shear traction on the contact. Shear force of sequentially-changing directions was considered and the corresponding shear traction was evaluated by extending the numerical tool for the Mindlin-Cattaneo problem.

  8. Defining a Theoretical Model of Wear - Caused Failure of Tool Machine Elements

    Directory of Open Access Journals (Sweden)

    B. Tadic

    2010-09-01

    Full Text Available This paper considers production equipment failures caused by wear. A short overview is given on the results of statistically processed data on production equipment failures, gained by observing 20 representative and, from the point of view of failure frequency, problematic machine elements. The goal of this research is to detect the current equipment condition having in mind reliability and create a theoretical base for optimal renewal part stock planning.

  9. Controlling wear failure of graphite-like carbon film in aqueous environment: Two feasible approaches

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yongxin [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Science, Lanzhou 730000 (China); Graduate School of the Chinese Academy of Sciences, Beijing 100039 (China); Wang Liping, E-mail: lpwang@licp.cas.cn [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Science, Lanzhou 730000 (China); Xue Qunji [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Science, Lanzhou 730000 (China)

    2011-02-15

    Friction and wear behaviors of graphite-like carbon (GLC) films in aqueous environment were investigated by a reciprocating sliding tribo-meter with ball-on-disc contact. Film structures and wear scars were studied by scanning electron microscope (SEM), energy dispersive spectroscopy (EDS) and a non-contact 3D surface profiler. A comprehensive wear model of the GLC film in aqueous environment was established, and two feasible approaches to control critical factor to the corresponding wear failure were discussed. Results showed that wear loss of GLC films in aqueous environment was characterized by micro-plough and local delamination. Due to the significant material loss, local delamination of films was critical to wear failure of GLC film in aqueous environment if the film was not prepared properly. The initiation and propagation of micro-cracks within whole films closely related to the occurrence of the films delamination from the interface between interlayer and substrate. The increase of film density by adjusting the deposition condition would significantly reduce the film delamination from substrate, meanwhile, fabricating a proper interlayer between substrate and GLC films to prevent the penetration of water molecules into the interface between interlayer and substrate could effectively eliminate the delamination.

  10. Material wear and failure mode analysis of breakfast cereal extruder barrels and screw elements

    Science.gov (United States)

    Mastio, Michael Joseph, Jr.

    2005-11-01

    Nearly seventy-five years ago, the single screw extruder was introduced as a means to produce metal products. Shortly after that, the extruder found its way into the plastics industry. Today much of the world's polymer industry utilizes extruders to produce items such as soda bottles, PVC piping, and toy figurines. Given the significant economical advantages of extruders over conventional batch flow systems, extruders have also migrated into the food industry. Food applications include the meat, pet food, and cereal industries to name just a few. Cereal manufacturers utilize extruders to produce various forms of Ready-to-Eat (RTE) cereals. These cereals are made from grains such as rice, oats, wheat, and corn. The food industry has been incorrectly viewed as an extruder application requiring only minimal energy control and performance capability. This misconception has resulted in very little research in the area of material wear and failure mode analysis of breakfast cereal extruders. Breakfast cereal extruder barrels and individual screw elements are subjected to the extreme pressures and temperatures required to shear and cook the cereal ingredients, resulting in excessive material wear and catastrophic failure of these components. Therefore, this project focuses on the material wear and failure mode analysis of breakfast cereal extruder barrels and screw elements, modeled as a Discrete Time Markov Chain (DTMC) process in which historical data is used to predict future failures. Such predictive analysis will yield cost savings opportunities by providing insight into extruder maintenance scheduling and interchangeability of screw elements. In this DTMC wear analysis, four states of wear are defined and a probability transition matrix is determined based upon 24,041 hours of operational data. This probability transition matrix is used to predict when an extruder component will move to the next state of wear and/or failure. This information can be used to determine

  11. Vibration analysis of shell-and-tube heat exchangers: an overview-Part 2: vibration response, fretting-wear, guidelines

    Science.gov (United States)

    Pettigrew, M. J.; Taylor, C. E.

    2003-11-01

    Design guidelines were developed to prevent tube failures due to excessive flow-induced vibration in shell-and-tube heat exchangers. An overview of vibration analysis procedures and recommended design guidelines is presented in this paper. This paper pertains to liquid, gas and two-phase heat exchangers such as nuclear steam generators, reboilers, coolers, service water heat exchangers, condensers, and moisture-separator-reheaters. Part 2 of this paper covers forced vibration excitation mechanisms, vibration response prediction, resulting damage assessment, and acceptance criteria.

  12. Fretting properties of biodegradable Mg-Nd-Zn-Zr alloy in air and in Hank's solution.

    Science.gov (United States)

    Li, Wenting; Li, Nan; Zheng, Yufeng; Yuan, Guangyin

    2016-11-04

    Fretting is a significant cause for the failure of orthopedic implants. Currently, since magnesium and its alloys have been developed as promising biodegradable implant materials, the fretting behavior of the Mg alloys is of great research significance. In this study, a Mg-Nd-Zn-Zr alloy (hereafter, denoted as JDBM alloy) was selected as experimental material, and its fretting behaviors were evaluated under 5 N, 10 N and 20 N normal loads with a displacement of 200 μm under the frequency of 10 Hz at 37 °C in air and in Hank's solution, respectively. The results indicated that while the friction coefficient decreased with the increment of the normal load, the wear volume of the alloy increased with the increment of the normal load both in air and in Hank's solution. Both the friction coefficients and the wear volume of the fretting in Hank's solution were much lower than those in air environment. The evolution trend of friction coefficients with time had different performance in air environment and the Hank's solution group. Although oxidation occurred during the fretting tests in Hank's solution, the damage of JDBM alloy was still reduced due to the lubrication effects of Hank's solution. Moreover, the addition of Fetal bovine serum (FBS) could act as lubrication and result in the reduction of the fretting damage.

  13. Wear and Failure Mechanism of PTFE/SiO2/Epoxy Composites

    NARCIS (Netherlands)

    Shen, J.T.; Pei, Y.T.; De Hosson, J.Th.M.

    2016-01-01

    In this work, the wear and failure mechanism of polytetrafluoroethylene (PTFE)/SiO2/epoxy composites with a high concentration of SiO2 particles under dry sliding is examined. In the composite with 12.5 wt.% PTFE, a significant rise of the coefficient of friction (COF) appears after sliding over

  14. Failure analysis of wear of main clutch separating ring of heavy vehicles

    Institute of Scientific and Technical Information of China (English)

    SUN Xiao-long; LI Xiao-yan; ZHU You-li; XU Bin-shi

    2005-01-01

    The severe wear of separating ring is considered to be a main reason which leads to the improper declutch of the main clutch of heavy vehicles. The wear mechanism of the separating ring is not well understood. Scanning electron microscopy and transmission electron microscopy were employed to analyze the surface features and dislocation characteristics of the separating ring. The typical features of furrows and rolled tongue-like metal were found on the surface of separating ring by scanning electron microscopy observation, which can be considered as a major indi cation of the grain-abrasion. A zone of high density dislocation was noted on the subsurface of the separating ring by transmission electron microscopy observation, which implies the contribution of the severe impact on the surface of the separating ring in the wear process. The influences of the structure of the separating ring, the service condition and the in-service stress distribution on the wear behavior, were also analyzed. The results show that the failure of separating ring results from the impact wear and grain-abrasion together with the plastic deformation.

  15. WEAR FAILURE MECHANISM AND MULTI-IMPACT PROPERTY OF AUTOMOTIVE ENGINE CHAIN

    Institute of Scientific and Technical Information of China (English)

    Meng Fanzhong; Wang Shukun; Lan Hong; Xu Rongjin; Xu Hanxue

    2005-01-01

    The multi-impact characteristics and failure mechanism of two kinds of automotive engine chain made in China are studied through engine assembly and road-drive tests. The worn surface morphologies of rubbing area between pin, bush and roller are also analyzed based on scanning electron microscope. The results show that the main wear mechanism of automotive engine chain is fatigue wear, and its failure mechanism is the forming, extending and flaking of cracks on top layer of pin and bush. In addition, the material, hot-treatment method and shaping technique for roller have a great influence upon the resistance to multi-impact. Ensuring sufficient strength and plasticity of roller, as well as adopting suitable shaping technique are the effective method to increase its resistance to multi-impact.

  16. Fretting properties of biodegradable Mg-Nd-Zn-Zr alloy in air and in Hank’s solution

    Science.gov (United States)

    Li, Wenting; Li, Nan; Zheng, Yufeng; Yuan, Guangyin

    2016-11-01

    Fretting is a significant cause for the failure of orthopedic implants. Currently, since magnesium and its alloys have been developed as promising biodegradable implant materials, the fretting behavior of the Mg alloys is of great research significance. In this study, a Mg-Nd-Zn-Zr alloy (hereafter, denoted as JDBM alloy) was selected as experimental material, and its fretting behaviors were evaluated under 5 N, 10 N and 20 N normal loads with a displacement of 200 μm under the frequency of 10 Hz at 37 °C in air and in Hank’s solution, respectively. The results indicated that while the friction coefficient decreased with the increment of the normal load, the wear volume of the alloy increased with the increment of the normal load both in air and in Hank’s solution. Both the friction coefficients and the wear volume of the fretting in Hank’s solution were much lower than those in air environment. The evolution trend of friction coefficients with time had different performance in air environment and the Hank’s solution group. Although oxidation occurred during the fretting tests in Hank’s solution, the damage of JDBM alloy was still reduced due to the lubrication effects of Hank’s solution. Moreover, the addition of Fetal bovine serum (FBS) could act as lubrication and result in the reduction of the fretting damage.

  17. EXPERIMENTAL INVESTIGTION OF THE FRETTING PHENOMENON

    Directory of Open Access Journals (Sweden)

    Ştefan GHIMISI

    2015-12-01

    Full Text Available Fretting is now fully identified as a small amplitude oscilatory motion which induces a harmonic tangential force between two surfaces in contact.It is related to three main loadings, i.e. fretting-wear, fretting-fatigue and fretting corrosion.Fretting regimes were first mapped by Vingsbo. In a similar way, three fretting regimes will be considered: stick regime,slip regime and mixed regime. The mixed regime was made up of initial gross slip followed by partial slip condition after a few hundred cycles. Obviously the partial slip transition develops the highest stress levels which can induce fatigue crack nucleation depending on the fatigue properties of the two contacting first bodies. Therefore prediction of the frontier between partial slip and gross slip is required.

  18. Effects of Nitriding and Laser Quenching on Fretting Wear Resistance of 18Cr2Ni4WA Steel%氮化激光淬火复合处理对18Cr2Ni4WA钢抗微动磨损性能的影响

    Institute of Scientific and Technical Information of China (English)

    李助军; 陈泽宇; 陈选民; 周欢伟

    2011-01-01

    Fretting wear resistance of 18Cr2Ni4WA steel with nitriding and laser quenching was studied on a SRV Ⅳ oscillating friction and wear tester.The results show that the hardness of sample after nitriding and laser quenching is about 780 HV, and the sample has excellent fretting wear resistance.The main fretting wear mechanism is abrasive wear and adhesion wear.%在SRVⅣ微动磨损试验机上考察了氮化激光复合处理和正火+高温回火处理对18Cr2Ni4WA钢抗微动磨损性能的影响.结果表明:在试验条件下,渗氮激光复合处理试样的维氏硬度约为780 HV,具有较好的抗微动磨损性能.磨损机理主要为粘着磨损和磨粒磨损.

  19. Fault tree analysis of most common rolling bearing tribological failures

    Science.gov (United States)

    Vencl, Aleksandar; Gašić, Vlada; Stojanović, Blaža

    2017-02-01

    Wear as a tribological process has a major influence on the reliability and life of rolling bearings. Field examinations of bearing failures due to wear indicate possible causes and point to the necessary measurements for wear reduction or elimination. Wear itself is a very complex process initiated by the action of different mechanisms, and can be manifested by different wear types which are often related. However, the dominant type of wear can be approximately determined. The paper presents the classification of most common bearing damages according to the dominant wear type, i.e. abrasive wear, adhesive wear, surface fatigue wear, erosive wear, fretting wear and corrosive wear. The wear types are correlated with the terms used in ISO 15243 standard. Each wear type is illustrated with an appropriate photograph, and for each wear type, appropriate description of causes and manifestations is presented. Possible causes of rolling bearing failure are used for the fault tree analysis (FTA). It was performed to determine the root causes for bearing failures. The constructed fault tree diagram for rolling bearing failure can be useful tool for maintenance engineers.

  20. Experimental and Numerical Investigations of Fretting Fatigue Behavior for Steel Q235 Single-Lap Bolted Joints

    Directory of Open Access Journals (Sweden)

    Yazhou Xu

    2016-01-01

    Full Text Available This work aims to investigate the fretting fatigue life and failure mode of steel Q235B plates in single-lap bolted joints. Ten specimens were prepared and tested to fit the S-N curve. SEM (scanning electron microscope was then employed to observe fatigue crack surfaces and identify crack initiation, crack propagation, and transient fracture zones. Moreover, a FEM model was established to simulate the stress and displacement fields. The normal contact stress, tangential contact stress, and relative slipping displacement at the critical fretting zone were used to calculate FFD values and assess fretting fatigue crack initiation sites, which were in good agreement with SEM observations. Experimental results confirmed the fretting fatigue failure mode for these specimens. It was found that the crack initiation resulted from wear regions at the contact surfaces between plates, and fretting fatigue cracks occurred at a certain distance away from hole edges. The proposed FFD-N relationship is an alternative approach to evaluate fretting fatigue life of steel plates in bolted joints.

  1. Fretting fatigue in AISI 1015 steel

    Indian Academy of Sciences (India)

    R Gnanamoorthy; R Rosi Reddy

    2002-04-01

    A small osillatory movement between two contacting surfaces is termed as fretting and on many occasions it acts as the crack initiation site leading to catastrophic failure of the overall structure. The occurrence of fretting is observed in many engineering structures such as shaft flanges, gas turbines, steel ropes etc. An experimental facility, which can simulate the fretting fatigue in many engineering applications, is the primary requirement of the research program. A laboratory fretting fatigue test facility capable of varying many influencing parameters of fretting fatigue such as slip amplitutde, frequency, contact pressure, etc is designed and developed. Preliminary investigations on plain and fretting fatigue behaviour of AISI 1015 structural steel are reported in this paper. A strength reduction factor of about 1.30 was obtained due to fretting for the test material under the present experimental conditions. Influence of contact load on fretting was also studied. Increasing fretting contact load decreased the fatigue life in the range investigated. Failure analysis showed typical stage I oblique crack growth followed by stage II straight crack perpedicular to the fretting zone.

  2. MOM Failure Modes: An In-Depth Look at Metal Ions and Implant Wear

    Directory of Open Access Journals (Sweden)

    Tom Donaldson, MD

    2014-03-01

    Full Text Available Contemporary MOM bearings (large-diameter heads offered the perceived benefits of much greater range of motion and greater stability with reduced risk of impingement and dislocation. A variety of design and Both positive [1-3] and negative reports [4-8] have now emerged with regard to total hip arthroplasty (THA and resurfacing arthroplasty. As a result, there has been an avalanche of studies focused on critical issues such as: surgical positioning, shallow cups (face angles 144-170° [9-11] and “edge loading”. [5,7,12-17] However, there are several, possibly synergistic, risk scenarios that could trigger adverse MOM wear and very little progress has been made in understanding such interacting parameters. In an effort to understand the role of metal ion analysis and how it relates to revision surgery and implant wear, selected MOM revised cases were reviewed [28]. Retrieval data was included in conjunction with metal ion analyses and intraoperative observations to determine various failure modes.  We suggest MOM devices that are well fixed but fail after 2 years can be classified into one of six modes: (i normal, (ii allergic reaction, (iii 3rd body wear, (iv repetitive subluxation with metal impingement, (v multi-directional subluxation with soft tissue impingement, and (vi repetitive subluxation with soft tissue impingement.

  3. Effects of Process Conditions on Fretting Wear Properties of Thermal Sprayed NiCr/WC Nanostructured Coating%喷涂工艺参数对热喷涂纳米镍铬碳化钨涂层微动磨损性能的影响

    Institute of Scientific and Technical Information of China (English)

    刘胜林; 郑雪萍

    2012-01-01

    以纳米NiCr/WC复合粉末(其中70%的WC与30%的NiCr)(文中含量均为质量分数)为原料,采用活性燃烧超音速火焰喷涂技术制备了纳米NiCr/WC复合涂层.利用SRV高温磨损试验机进行微动磨损试验,结果显示,在其它工艺参数相同的条件下,纳米涂层在喷涂距离为200 mm条件下的耐磨性能最差,在喷涂距离为160 mm条件下的耐磨性能最好;纳米涂层在送粉率为5 rpm条件下的耐磨性能最差,在送粉率为15 rpm条件下的耐磨性能最好.此外,与综合性能优良的渗碳轴承钢20CrNi2Mo相比,所有的纳米涂层的耐磨损性能都明显优于相同温度条件下的轴承钢的耐磨损性能.%Nanostructured coatings of NiCr/WC (70% WC, 30%NiCr) were prepared via actived-combustion-high velocity air fuel (AC-HVAF). Fretting wear test was carried out by SRV high, temperature wearing equipment The results show that the thermal sprayed NiCr/WC nanostructured coating prepared from the spraying distance of 160 mm has the best fretting wear properties under the same other process parameters, and the nanostructured coating prepared from the spraying distance of 200 mm has the worst fretting wear properties. The nanostructured coating prepared at the powder feed rate of 15 rpm has the best fretting wear properties under the same other process parameters, the nanostructured coating prepared at the powder feed rate of 5 rpm has the worst fretting wear properties, respectively. In addition, compared to the carburizing bearing steel 20CrNi2Mo with excellent overall performance, the wearing resistances of all nanostructured coatings are better than that of the carburizing bearing steel under the same wear conditions.

  4. Standard guide for fretting fatigue testing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide defines terminology and covers general requirements for conducting fretting fatigue tests and reporting the results. It describes the general types of fretting fatigue tests and provides some suggestions on developing and conducting fretting fatigue test programs. 1.2 Fretting fatigue tests are designed to determine the effects of mechanical and environmental parameters on the fretting fatigue behavior of metallic materials. This guide is not intended to establish preference of one apparatus or specimen design over others, but will establish guidelines for adherence in the design, calibration, and use of fretting fatigue apparatus and recommend the means to collect, record, and reporting of the data. 1.3 The number of cycles to form a fretting fatigue crack is dependent on both the material of the fatigue specimen and fretting pad, the geometry of contact between the two, and the method by which the loading and displacement are imposed. Similar to wear behavior of materials, it is important t...

  5. Effects of grain size and humidity on fretting wear in fine-grained alumina, Al{sub 2}O{sub 3}/TiC, and zirconia

    Energy Technology Data Exchange (ETDEWEB)

    Krell, A. [Fraunhofer Inst. for Ceramic Technologies and Sintered Materials, Dresden (Germany); Klaffke, D. [Federal Inst. for Materials Research and Testing, Berlin (Germany)

    1996-05-01

    Friction and wear of sintered alumina with grain sizes between 0.4 and 3 {micro}m were measured in comparison with Al{sub 2}O{sub 3}/TiC composites and with tetragonal ZrO{sub 2} (3 mol% Y{sub 2}O{sub 3}). The dependence on the grain boundary toughness and residual microstresses is investigated, and a hierarchical order of influencing parameters is observed. In air, reduced alumina grain sizes improve the micromechanical stability of the grain boundaries and the hardness, and reduced wear is governed by microplastic deformation, with few pullout events. Humidity and water slightly reduce the friction of all of the investigated ceramics. In water, this effect reduces the wear of coarser alumina microstructures. The wear of aluminas and of the Al{sub 2}O{sub 3}/TiC composite is similar; it is lower than observed in zirconia, where extended surface cracking occurs at grain sizes as small as 0.3 {micro}m.

  6. CONSIDERATIONS REGARDING THE FRETTING PHENOMENON USING LEAF SPRINGS

    Directory of Open Access Journals (Sweden)

    Stefan GHIMIȘI

    2015-05-01

    Full Text Available The fretting phenomenon represents particulary and complex form of wear who is; generaly, and/or weary of fretting who is produced on the load contact in a relative oscialatory movement lay small amplitude.A simultaneoustly applied tangential force and normal into contact appears a adhesion force

  7. Large-eddy simulation, fuel rod vibration and grid-to-rod fretting in pressurized water reactors

    Science.gov (United States)

    Christon, Mark A.; Lu, Roger; Bakosi, Jozsef; Nadiga, Balasubramanya T.; Karoutas, Zeses; Berndt, Markus

    2016-10-01

    Grid-to-rod fretting (GTRF) in pressurized water reactors is a flow-induced vibration phenomenon that results in wear and fretting of the cladding material on fuel rods. GTRF is responsible for over 70% of the fuel failures in pressurized water reactors in the United States. Predicting the GTRF wear and concomitant interval between failures is important because of the large costs associated with reactor shutdown and replacement of fuel rod assemblies. The GTRF-induced wear process involves turbulent flow, mechanical vibration, tribology, and time-varying irradiated material properties in complex fuel assembly geometries. This paper presents a new approach for predicting GTRF induced fuel rod wear that uses high-resolution implicit large-eddy simulation to drive nonlinear transient dynamics computations. The GTRF fluid-structure problem is separated into the simulation of the turbulent flow field in the complex-geometry fuel-rod bundles using implicit large-eddy simulation, the calculation of statistics of the resulting fluctuating structural forces, and the nonlinear transient dynamics analysis of the fuel rod. Ultimately, the methods developed here, can be used, in conjunction with operational management, to improve reactor core designs in which fuel rod failures are minimized or potentially eliminated. Robustness of the behavior of both the structural forces computed from the turbulent flow simulations and the results from the transient dynamics analyses highlight the progress made towards achieving a predictive simulation capability for the GTRF problem.

  8. Axisymmetric fretting analysis in coated cylinder

    Indian Academy of Sciences (India)

    M Ramesh; Satish V Kailas; K R Y Simha

    2008-06-01

    Fretting is essentially a contact fatigue phenomenon, although bulk stresses and material properties contribute to final failure. The near surface state of stress developed under oscillatory contact between machine elements plays a major role in deciding the severity of fretting. It is possible to enhance tribological properties by coating the surface. There is rather scanty literature available on fretting analysis of coated components. Presence of such coatings has a large influence on the near surface state of stress. The effect of coatings on the severity of fretting is the focus of this paper. Results obtained for both hard and soft coatings are compared with the results obtained for the homogeneous case. The component geometry and loading are chosen to be cylindrical to enable 3D elastic axisymmetric fretting analysis. The results are compared with 2D models (strip and half-plane) to examine their utility and validity for understanding axisymmetric fretting. Contact pressure and frictional shear loading cases are solved separately and superposed appropriately depending on the coefficient of friction considered. Results for different values of coefficient of friction and elastic mismatch are illustrated through contour plots of stresses and strains. These results are expected to be helpful for identifying fretting failure zones and fracture mechanisms in coated components. Analytical results presented here could serve as useful benchmarks for calibrating numerical codes and experimental techniques.

  9. Design of wear-out-failure in-situ repair parts by environment-friendly nanocopper additive

    Institute of Scientific and Technical Information of China (English)

    YU He-long; XU Bin-shi; XU Yi; WANG Xiao-li; LIU Qian

    2005-01-01

    Oleic acid surface-modified Cu nanoparticles with an average size of 20 nm were prepared by liquid phase reducing reaction. The tribological performance and mechanism of nanocopper as additive were studied by means of tribotester, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and nanoindentation instrument. The results indicate that the modified nanocopper additive can significantly improve the wear resistance and reduce friction coefficient of base oil. A copper protective film is formed and contributes to the excellent tribological properties of nanocopper additive. On the basis of the film forming mechanism, a new in-situ repair method was designed and used to repair wear-out-failure injection pump plunger and barrel. Furthermore, the current research progress of nanoparticles as green energy-saving lubricating oil additives were presented.

  10. Wear and Adhesive Failure of Al2O3 Powder Coating Sprayed onto AISI H13 Tool Steel Substrate

    Science.gov (United States)

    Amanov, Auezhan; Pyun, Young-Sik

    2016-07-01

    In this study, an alumina (Al2O3) ceramic powder was sprayed onto an AISI H13 hot-work tool steel substrate that was subjected to sanding and ultrasonic nanocrystalline surface modification (UNSM) treatment processes. The significance of the UNSM technique on the adhesive failure of the Al2O3 coating and on the hardness of the substrate was investigated. The adhesive failure of the coating sprayed onto sanded and UNSM-treated substrates was investigated by a micro-scratch tester at an incremental load. It was found, based on the obtained results, that the coating sprayed onto the UNSM-treated substrate exhibited a better resistance to adhesive failure in comparison with that of the coating sprayed onto the sanded substrate. Dry friction and wear property of the coatings sprayed onto the sanded and UNSM-treated substrates were assessed by means of a ball-on-disk tribometer against an AISI 52100 steel ball. It was demonstrated that the UNSM technique controllably improved the adhesive failure of the Al2O3 coating, where the critical load was improved by about 31%. Thus, it is expected that the application of the UNSM technique to an AISI H13 tool steel substrate prior to coating may delay the adhesive failure and improve the sticking between the coating and the substrate thanks to the modified and hardened surface.

  11. The Delamination Theory of Wear

    Science.gov (United States)

    1974-09-01

    junctions, it is still based on the assumption that the deformation occurs at the asperities. Rabinowicz [14] advanced an adhesion theory of friction...shown that bronze particles were indeed bigger than steel particles. The compilation of wear particle sizes given by Rabinowicz [14] also indicates...Waterhouse [32] has shown that, in fact, fretting occurs by delamination. 6) Minimum Load for Loose Particle Formation Rabinowicz [14] found that no wear

  12. Near surface stress analysis strategies for axisymmetric fretting

    Indian Academy of Sciences (India)

    M Ramesh; Satish V Kailas; K R Y Simha

    2008-06-01

    Fretting is essentially a surface phenomenon, but bulk stresses and material properties contribute to subsequent failure. This feature of fretting demands a thorough understanding of near surface stresses under the joint action of normal, shear and thermal loading. Axisymmetric fretting is of great concern in piping and coupling design. In this paper, we develop design tools for Near Surface Analysis (NSA) for understanding axisymmetric fretting. Axisymmetric Fretting Analysis (AFA) becomes formidable owing to localised tractions that call for Fourier transform techniques. We develop two different NSA strategies based on two-dimensional plane strain models: 2D strip model (2DS) and half-plane Flamant model (2DF). We compare the results of 2DS and 2DF with the exact results for AFA obtained using Love’s stress function in conjunction with Fourier transform. There is a good correspondence between stress components obtained from 2D-models.

  13. IIem-spFRET: improved Iem-spFRET method for robust FRET measurement

    Science.gov (United States)

    Zhang, Jiang; Lin, Fangrui; Chai, Liuying; Wei, Lichun; Chen, Tongsheng

    2016-10-01

    We recently developed a quantitative Förster resonance energy transfer (FRET) measurement method based on emission-spectral unmixing (Iem-spFRET). We here developed an improved Iem-spFRET method (termed as IIem-spFRET) for more robust FRET measurement in living cells. First, two background (BG) spectral fingerprints measured from blank living cells are introduced to remove BG and autofluorescence. Second, we introduce a ρ factor denoting the ratio of two molar extinction coefficient ratios (γ) of acceptor to donor at two excitations into IIem-spFRET for direct measurement of the γ values using a tandem construct with unknown FRET efficiency (E). We performed IIem-spFRET on our microscope-spectrometer platform to measure the γ values of Venus (V) to Cerulean (C) and the E values of C32V, CVC, VCV, and VCVV constructs, respectively, in living Huh7 cells. For the C32V or CVC cells, the Iem-spFRET and IIem-spFRET methods measured consistent E values. However, for the cells especially with low expressing levels of VCV or VCVV, the E values measured by Iem-spFRET showed large deviations and fluctuations, whereas the IIem-spFRET method greatly improved the measured E values. Collectively, IIem-spFRET is a powerful and robust tool for quantitatively measuring FRET signal in living cells.

  14. Considerations for sensitivity analysis, uncertainty quantification, and data assimilation for grid-to-rod fretting

    Energy Technology Data Exchange (ETDEWEB)

    Michael Pernice

    2012-10-01

    Grid-to-rod fretting is the leading cause of fuel failures in pressurized water reactors, and is one of the challenge problems being addressed by the Consortium for Advanced Simulation of Light Water Reactors to guide its efforts to develop a virtual reactor environment. Prior and current efforts in modeling and simulation of grid-to-rod fretting are discussed. Sources of uncertainty in grid-to-rod fretting are also described.

  15. Fretting damage behavior and mechanism of tin coated zircaloy-4 tube

    Institute of Scientific and Technical Information of China (English)

    Tae-HyungKim; Ji-HyunSung; Seock-SamKim

    2001-01-01

    The fretting characteristics of TiN coated Zircaloy-4 tube were investigated experimen-tally. The fretting experiment was performed using TIN coated Zircaloy-4 tube as the fuel rod clad-ding material and uncoated Zircaloy-4 tube as one of grids. TIN coating is probably one of the mostfrequently and successfully used PVD coatings for the mitigation of fretting. In this study, TiN coat-ing by PVD was employed for improvement of Zircaloy-4 tube fretting characteristics. The frettingtester was designed and manufactured for this experiment. The number of cycles, slip amplitudeand normal load were selected as main factors of fretting. The results of this research showed thatthe wear volume of TiN coated Zircaloy-4 tube increased as number of cycles, normal load andslip amplitude increase but the quantity of volume was lower than the case of uncoated Zircaloy-4tube pairs.

  16. Influence of oil and water media on fretting behaviour of AISI 52100 steel rubbing against AISI 1045 steel

    Institute of Scientific and Technical Information of China (English)

    REN Ping-di; CHEN Guang-xiong; ZHU Min-hao; ZHOU Zhong-rong

    2004-01-01

    A series of fretting test were carried out using a DELTA PLINT testing system to study the influence of hydraulic oil and water on fretting behaviour of AISI 52100 steel rubbing against AISI 1045 steel. The test result shows that media hydraulic oil and water have a distinct influence on fretting behaviour of the tested materials. Medium water can lead to shifting of the partial slip regime in the fretting map from a larger displacement amplitude toward a smaller one and enlargement of the mixed slip regime, in comparison with that in ambient atmosphere. While medium hydraulic oil can result in shifting of the partial slip regime from a smaller displacement amplitude toward a larger one. In the gross slip regime, hydraulic oil and water play a positive role as lubrication media. They can clearly decrease the fretting friction coefficient between AISI 52100 and AISI 1045. The test result also demonstrates that this lubrication effect will get better with increasing displacement amplitude and that hydraulic oil is better than water for lubrication. SEM observation of the wear scars displays that the fretting wear mainly results from abrasive wear and delamination of the fretted materials when using these two kinds of substances as lubrication media.

  17. Fretting and Corrosion Between a Metal Shell and Metal Liner May Explain the High Rate of Failure of R3 Modular Metal-on-Metal Hips.

    Science.gov (United States)

    Ilo, Kevin C; Derby, Emma J; Whittaker, Robert K; Blunn, Gordon W; Skinner, John A; Hart, Alister J

    2017-05-01

    The R3 acetabular system used with its metal liner has higher revision rates when compared to its ceramic and polyethylene liner. In June 2012, the medical and healthcare products regulatory agency issued an alert regarding the metal liner of the R3 acetabular system. Six retrieved R3 acetabular systems with metal liners underwent detailed visual analysis using macroscopic and microscopic techniques. Visual analysis discovered corrosion on the backside of the metal liners. There was a distinct border to the areas of corrosion that conformed to antirotation tab insertions on the inner surface of the acetabular shell, which are for the polyethylene liner. Scanning electron microscopy indicated evidence of crevice corrosion, and energy-dispersive X-ray analysis confirmed corrosion debris rich in titanium. The high failure rate of the metal liner option of the R3 acetabular system may be attributed to corrosion on the backside of the liner which appear to result from geometry and design characteristics of the acetabular shell. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Fretting Fatigue of Gamma TiAl Studied

    Science.gov (United States)

    Miyoshi, Kazuhisa; Lerch, Bradley A.; Draper, Susan L.

    2003-01-01

    Gamma titanium-aluminum alloy (g-TiAl) is an attractive new material for aerospace applications because of its low density and high specific strength in comparison to currently used titanium and nickel-base alloys. Potential applications for this material are compressor and low-pressure turbine blades. These blades are fitted into either the compressor or turbine disks via a dovetail connection. The dovetail region experiences a complex stress state due to the alternating centrifugal force and the natural high-frequency vibration of the blade. Because of the dovetail configuration and the complex stress state, fretting is often a problem in this area. Furthermore, the local stress state becomes more complex when the influence of the metal-metal contact and the edge of the contact is evaluated. Titanium and titanium-based alloys in the clean state exhibit strong adhesive bonds when in contact with themselves and other materials (refs. 1 and 2). This adhesion causes heavy surface damage and high friction in practical cases. Although the wear produced by fretting may be mild, the reduction in fatigue life can be substantial. Thus, there is the potential for fretting problems with these TiAl applications. Since TiAl is an emerging material, there has been limited information about its fretting behavior.

  19. Combined effects of fretting and pollutant particles on the contact resistance of the electrical connectors

    Directory of Open Access Journals (Sweden)

    Zhigang Kong

    2017-06-01

    Full Text Available Usually, when electrical connectors operate in vibration environments, fretting will be produced at the contact interfaces. In addition, serious environmental pollution particles will affect contact resistance of the connectors. The fretting will worsen the reliability of connectors with the pollutant particles. The combined effects of fretting and quartz particles on the contact resistance of the gold plating connectors are studied with a fretting test system. The results show that the frequencies have obvious effect on the contact resistance. The higher the frequency, the higher the contact resistance is. The quartz particles cause serious wear of gold plating, which make the nickel and copper layer exposed quickly to increase the contact resistance. Especially in high humidity environments, water supply certain adhesion function and make quartz particles easy to insert or cover the contact surfaces, and even cause opening resistance.

  20. Fretting corrosion of CoCr alloy: Effect of load and displacement on the degradation mechanisms.

    Science.gov (United States)

    Bryant, Michael; Neville, Anne

    2017-02-01

    Fretting corrosion of medical devices is of growing concern, yet, the interactions between tribological and electrochemical parameters are not fully understood. Fretting corrosion of CoCr alloy was simulated, and the components of damage were monitored as a function of displacement and contact pressure. Free corrosion potential (Ecorr), intermittent linear polarisation resistance and cathodic potentiostatic methods were used to characterise the system. Interferometry was used to estimate material loss post rubbing. The fretting regime influenced the total material lost and the dominant degradation mechanism. At high contact pressures and low displacements, pure corrosion was dominant with wear and its synergies becoming more important as the contact pressure and displacement decreased and increased, respectively. In some cases, an antagonistic effect from the corrosion-enhanced wear contributor was observed suggesting that film formation and removal may be present. The relationship between slip mechanism and the contributors to tribocorrosion degradation is presented.

  1. Control of Fretting Fatigue

    Science.gov (United States)

    1977-07-01

    Minnesota ERNEST RABINOWICZ , Professor, D^i artment of Mechanical Engineering, Massachusetts Institute of Technology. Cambridge, Massachusetts...on Problem Definition; to E, Rabinowicz and C. H. Wells on Fundamentals; to J. A. Collins, D. W. Hoeppner and C. N. Rowe on Design Approaches; and to...its original interface [ Rabinowicz and Tabor (141)]; Burwell and Strang (33); and Archard (12)]. Consequently, a wear particle is transferred from

  2. Microstructure-Wear Resistance Correlation and Wear Mechanisms of Spark Plasma Sintered Cu-Pb Nanocomposites

    Science.gov (United States)

    Sharma, Amit Siddharth; Biswas, Krishanu; Basu, Bikramjit

    2014-01-01

    The dispersion of a softer phase in a metallic matrix reduces the coefficient of friction (COF), often at the expense of an increased wear rate at the tribological contact. To address this issue, unlubricated fretting wear tests were performed on spark plasma sintered Cu-Pb nanocomposites against bearing steel. The sintering temperature and the Pb content as well as the fretting parameters were judiciously selected and varied to investigate the role of microstructure (grain size, second-phase content) on the wear resistance properties of Cu-Pb nanocomposites. A combination of the lowest wear rate (~1.5 × 10-6 mm3/Nm) and a modest COF (~0.4) was achieved for Cu-15 wt pct Pb nanocomposites. The lower wear rate of Cu-Pb nanocomposites with respect to unreinforced Cu is attributed to high hardness (~2 to 3.5 GPa) of the matrix, Cu2O/Fe2O3-rich oxide layer formation at tribological interface, and exuding of softer Pb particles. The wear properties are discussed in reference to the characteristics of transfer layer on worn surface as well as subsurface damage probed using focused ion beam microscopy. Interestingly, the flash temperature has been found to have insignificant effect on the observed oxidative wear, and alternative mechanisms are proposed. Importantly, the wear resistance properties of the nanocomposites reveal a weak Hall-Petch-like relationship with grain size of nanocrystalline Cu.

  3. Fretting fatigue behaviour of Ni-free high-nitrogen stainless steel in a simulated body fluid

    Directory of Open Access Journals (Sweden)

    Norio Maruyama, Sachiko Hiromoto, Eiji Akiyama and Morihiko Nakamura

    2013-01-01

    Full Text Available Fretting fatigue behaviour of Ni-free high-nitrogen steel (HNS with a yield strength of about 800 MPa, which was prepared by nitrogen gas pressurized electroslag remelting, was studied in air and in phosphate-buffered saline (PBS(-. For comparison, fretting fatigue behaviour of cold-rolled SUS316L steel (SUS316L(CR with similar yield strength was examined. The plain fatigue limit of HNS was slightly lower than that of SUS316L(CR although the former had a higher tensile strength than the latter. The fretting fatigue limit of HNS was higher than that of SUS316L(CR both in air and in PBS(-. A decrease in fatigue limit of HNS by fretting was significantly smaller than that of SUS316L(CR in both environments, indicating that HNS has better fretting fatigue resistance than SUS316L(CR. The decrease in fatigue limit by fretting is discussed taking into account the effect of friction stress due to fretting and the additional influences of wear, tribocorrosion and plastic deformation in the fretted area.

  4. Critical component wear in heavy duty engines

    CERN Document Server

    Lakshminarayanan, P A

    2011-01-01

    The critical parts of a heavy duty engine are theoretically designed for infinite life without mechanical fatigue failure. Yet the life of an engine is in reality determined by wear of the critical parts. Even if an engine is designed and built to have normal wear life, abnormal wear takes place either due to special working conditions or increased loading.  Understanding abnormal and normal wear enables the engineer to control the external conditions leading to premature wear, or to design the critical parts that have longer wear life and hence lower costs. The literature on wear phenomenon r

  5. SLIM for multispectral FRET imaging

    Science.gov (United States)

    Rück, A.; Dolp, F.; Steiner, R.; Steinmetz, C.; von Einem, B.; von Arnim, C. A. F.

    2008-02-01

    Spectral fluorescence lifetime imaging (SLIM) is an advanced imaging technique, which combines spectral with time resolved detection. Real spectral information is achieved by using a grating in front of a PML-array, which allows time-correlated single photon counting (TCSPC). Whereas spectrally resolved fluorescence imaging alone has a reasonable sensitivity, the specificity of fluorescence detection can be improved by considering the fluorescence lifetime. The various possibilities which SLIM offers to improve FRET (resonant energy transfer) will be discussed as well as successfully realized applications. These include FRET measurements for protein interactions, related to Alzheimer's disease. Special attention will be focused on molecules involved in the processing and trafficking of the amyloid precursor protein (APP), as trafficking proteins of the GGA family and β-secretase BACE). Taking into account also the lifetime of the acceptor could enhance reliability of the FRET result.

  6. Wear Failure Analysis on Dowel of Hydraulic Grab%工程机械常用销轴磨损失效分析

    Institute of Scientific and Technical Information of China (English)

    李毅; 冯坤

    2013-01-01

    The manufacture process of the dowel for construction machinery was quenching, tempering and surface hard chromium plating. The pin worked under a high load and a certain impact. Wear failure happened after three hundred hours in practical use. In this article, the wear mechanism of fractured pin was analyzed through metallographic observation, hardness testing, surface morphology analysis by SEM and EDS composition analysis. The result was showed that the main reason of failure of the pin was the big difference of hardness between chromium plating layer and matrix. Under high stress and impact, micro-breakout was occurred at chromium plating layer. In order to improve the surface hardness and eliminating the radial performance of mutations, surface quenching and surface carburizing was suggested to take the place of surface hard chromium plating.%某工程机械用销轴的制备工艺为调质处理+表面镀硬铬,其工作时需承受较高的载荷及一定的冲击,实际使用中约300 h发生了磨损失效。通过金相观察、硬度测试、扫描电镜表面形貌分析及能谱成分分析等检测方法对失效销轴的磨损原因进行分析。结果表明,该销轴磨损失效的主要原因是其表面镀铬层与基体的硬度差异较大,在高应力与冲击荷载的作用下,镀铬层发生了脆性剥落。可选用表面淬火、表面渗碳等工艺代替表面镀硬铬,提高销轴表面硬度的同时消除其径向性能的突变,提升销轴的使用寿命。

  7. Nanocomposite TiSiBC Hard Coatings with High Resistance to Wear, Fracture and Scratching

    Science.gov (United States)

    Mahato, P.; Nyati, G.; Singh, R. J.; Mishra, S. K.

    2016-09-01

    The sliding wear under fretting condition, scratch adhesion, deformation behavior during micro- and nanoscratch studies have been studied for nanocomposite TiSiBC hard coating deposited on steel substrate by magnetron sputtering. The nanocomposite coatings having hardness and modulus around 30 and 300 GPa, respectively, showed a very significant decrease in fretting wear as compared to the uncoated steel. Pileup occurred along the sides of the scratch track due to plastic deformation of the substrate at the scratch load; however, cracks were not seen in films. The coefficient of friction remained scratch, higher wear resistance, higher toughness and low coefficient of friction.

  8. Large-eddy simulations of turbulent flow for grid-to-rod fretting in nuclear reactors

    CERN Document Server

    Bakosi, J; Lowrie, R B; Pritchett-Sheats, L A; Nourgaliev, R R

    2013-01-01

    The grid-to-rod fretting (GTRF) problem in pressurized water reactors is a flow-induced vibration problem that results in wear and failure of the fuel rods in nuclear assemblies. In order to understand the fluid dynamics of GTRF and to build an archival database of turbulence statistics for various configurations, implicit large-eddy simulations of time-dependent single-phase turbulent flow have been performed in 3x3 and 5x5 rod bundles with a single grid spacer. To assess the computational mesh and resolution requirements, a method for quantitative assessment of unstructured meshes with no-slip walls is described. The calculations have been carried out using Hydra-TH, a thermal-hydraulics code developed at Los Alamos for the Consortium for Advanced Simulation of Light water reactors, a United States Department of Energy Innovation Hub. Hydra-TH uses a second-order implicit incremental projection method to solve the single-phase incompressible Navier-Stokes equations. The simulations explicitly resolve the la...

  9. Fretting Behavior of SPR Joining Dissimilar Sheets of Titanium and Copper Alloys

    Directory of Open Access Journals (Sweden)

    Xiaocong He

    2016-12-01

    Full Text Available The fretting performance of self-piercing riveting joining dissimilar sheets in TA1 titanium alloy and H62 copper alloy was studied in this paper. Load-controlled cyclic fatigue tests were carried out using a sine waveform and in tension-tension mode. Scanning electron microscopy and energy-dispersive X-ray techniques were employed to analyze the fretting failure mechanisms of the joints. The experimental results showed that there was extremely severe fretting at the contact interfaces of rivet and sheet materials for the joints at relatively high loads levels. Moreover, the severe fretting in the region on the locked sheet in contact with the rivet was the major cause of the broken locked sheet for the joints at low load level.

  10. Influence of fretting on the fatigue strength at the vise clamp–specimen interface

    Indian Academy of Sciences (India)

    Abdulhaqq A Hamid; Rafi K Yahya

    2003-12-01

    Fretting fatigue is one of the most important phenomena for inducing a significant reduction of fatigue strength and consequently, leading to unexpected failure accidents of the engineering structures even at very low stresses. In the present study, both plain and fretting fatigue tests with zero mean stress were carried out on two different types of steel, low-carbon steel and martensitic stainless steel, by means of a reversed bending fatigue testing machine. The drop in the fatigue strengths through fretting at vise clamp–specimen interface were significant for both tested steels. The fretting processes produced a reduction in fatigue strength of about 27% for low-carbon steel and 16% for martensitic stainless steel.

  11. Friction and Wear Behaviors of Nanostructured Metals

    Institute of Scientific and Technical Information of China (English)

    Zhong HAN; Yusheng ZHANG; Ke LU

    2008-01-01

    Nanostructured (ns) materials, i.e., polycrystalline materials with grain sizes in the nanometer regime (typically below 100 nm), have drawn considerable attention in the past decades due to their unique properties such as high strength and hardness. Wear resistance of ns materials, one of the most important properties for engineering materials, has been extensively investigated in the past decades. Obvious differences have been identified in friction and wear behaviors Between the ns materials and their corresponding coarse-grained (cg) counterparts, consistently correlating with their unique structure characteristics and mechanical properties. On the other hand, the superior tribological properties of ns materials illustrate their potential applications under contact loads. The present overview will summarize the important progresses achieved on friction and wear behaviors of ns metallic materials, including ultrafine-grained (ufg) materials in recent years. Tribological properties and effects on friction and wear behaviors of ns materials will be discussed under different wear conditions including abrasive wear, sliding wear, and fretting wear. Their correlations with mechanical properties will be analyzed. Perspectives on development of this field will be highlighted as well.

  12. A Study on Surface Modification of Al7075-T6 Alloy against Fretting Fatigue Phenomenon

    Directory of Open Access Journals (Sweden)

    E. Mohseni

    2014-01-01

    Full Text Available Aircraft engines, fuselage, automobile parts, and energy saving strategies in general have promoted the interest and research in the field of lightweight materials, typically on alloys based on aluminum. Aluminum alloy itself does not have suitable wear resistance; therefore, it is necessary to enhance surface properties for practical applications, particularly when aluminum is in contact with other parts. Fretting fatigue phenomenon occurs when two surfaces are in contact with each other and one or both parts are subjected to cyclic load. Fretting drastically decreases the fatigue life of materials. Therefore, investigating the fretting fatigue life of materials is an important subject. Applying surface modification methods is anticipated to be a supreme solution to gradually decreasing fretting damage. In this paper, the authors would like to review methods employed so far to diminish the effect of fretting on the fatigue life of Al7075-T6 alloy. The methods include deep rolling, shot peening, laser shock peening, and thin film hard coatings. The surface coatings techniques are comprising physical vapor deposition (PVD, hard anodizing, ion-beam-enhanced deposition (IBED, and nitriding.

  13. The Contact Ageing Effect on Fretting Damage of an Electro-Deposited Coating against an AISI52100 Steel Ball

    Directory of Open Access Journals (Sweden)

    Kyungmok Kim

    2016-09-01

    Full Text Available This article investigates the effect of contact ageing on fretting damage of an epoxy-based cathodic electro-deposited coating for use on automotive seat slide tracks (made of cold-rolled high strength steel. Static normal load was induced at the contact between the coating and an AISI52100 ball for a certain duration. It was identified that plastically deformed contact area increased logarithmically as a function of time when the contact was under static normal load. Fretting tests after various durations of static contact were conducted using a ball-on-flat plate apparatus. All fretting tests were halted when the friction coefficient reached a critical value of 0.5, indicating complete coating failure. The total number of fretting cycles to the critical friction coefficient was found to vary with the duration of static contact before fretting. It was identified that the number of cycles to the critical friction coefficient decreased with the increased duration of static contact. Meanwhile, the friction coefficient at steady-state sliding was not greatly affected by the duration of static contact before fretting. Finally, the relation between coating thickness after indentation creep and the number of cycles to the critical friction coefficient was found to be linear. Obtained results show that the duration of static contact before fretting has an influence on the fretting lifetime of an electro-deposited coating.

  14. Fluorescence Resonance Energy Transfer (FRET) sensor

    CERN Document Server

    Hussain, Syed Arshad; Chakraborty, Sekhar; Saha, Jaba; Roy, Arpan Datta; Chakraborty, Santanu; Debnath, Pintu; Bhattacharjee, D

    2014-01-01

    The applications of Fluorescence resonance energy transfer (FRET) have expanded tremendously in the last 25 years, and the technique has become a staple technique in many biological and biophysical fields. FRET can be used as spectroscopic ruler in various areas such as structural elucidation of biological molecules and their interactions, in vitro assays, in vivo monitoring in cellular research, nucleic acid analysis, signal transduction, light harvesting, and metallic nanomaterials etc. Based on the mechanism of FRET a variety of novel chemical sensors and Biosensors have been developed. This review highlights the recent applications of sensitive and selective ratiometric FRET based sensors.

  15. A comparative study on the wear behaviors of cladding candidates for accident-tolerant fuel

    Science.gov (United States)

    Lee, Young-Ho; Byun, Thak Sang

    2015-10-01

    Accident-tolerant fuels are expected to have considerably longer coping time to respond to the loss of active cooling under severe accidents and, at the same time, have comparable or improved fuel performance during normal operation. The wear resistance of accident tolerant fuels, therefore, needs to be examined to determine the applicability of these cladding candidates to the current operating PWRs because the most common failure of nuclear fuel claddings is still caused by grid-to-rod fretting during normal operations. In this study, reciprocating sliding wear tests on three kinds of cladding candidates for accident-tolerant fuels have been performed to investigate the tribological compatibilities of self-mated cladding candidates and to determine the direct applicability of conventional Zirconium-based alloys as supporting structural materials. The friction coefficients of the cladding candidates are strongly influenced by the test environments and coupled materials. The wear test results under water lubrication conditions indicate that the supporting structural materials for the cladding candidates of accident-tolerant fuels need to be replaced with the same cladding materials instead of using conventional Zirconium-based alloys.

  16. Correlation between Wear Resistance and Lifetime of Electrical Contacts

    Directory of Open Access Journals (Sweden)

    Jian Song

    2012-01-01

    Full Text Available Electrical contacts are usually plated in order to prevent corrosion. Platings of detachable electrical contacts experience wear because of the motion between contacts. Once the protecting platings have been worn out, electrical contacts will fail rapidly due to corrosion or fretting corrosion. Therefore the wear resistance of the platings is a very important parameter for the long lifetime of electrical contacts. Many measures which improve the wear resistance can diminish the conductivity of the platings. Due to the fact that platings of electrical contacts must have both a high wear resistance and a high electrical conductivity, the manufacturing of high performance platings of electrical contacts poses a great challenge. Our study shows firstly the correlation between the wear resistance of platings and lifetime of electrical contacts and then the measures, which improve the wear resistance without impairing the electrical performance of the contacts.

  17. Influence of surface coating on Ti811 alloy resistance to fretting fatigue at elevated temperature

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xiaohua; LIU Daoxin

    2009-01-01

    An extensive study of the composition distribution, bonding strength, hardness, and wear resistance of a 0Cr18Ni9 film deposited on a Ti811 titanium alloy surface by ion beam enhanced deposition (IBED) is presented. Shot peening was introduced to post-treat the modified surface to synergistically improve the fretting fatigue resistance of the Ti811 alloy at 350~C. The results indicate that the 0Cr18Ni9 film with high density, small grain size, low void radio, and high bonding strength can be prepared using IBED. As a result, the hardness, wear resistance, and fretting fatigue resistance of the Ti811 alloy are increased to a remarkable extent. Compared with shot peening treatment or IBED 0Cr18Ni9 film alone, the Ti811 titanium alloy with an IBED 0Cr18Ni9 film combined with shot peening shows a higher fretting fatigue resistance at 350℃. This is due to the synergistic effect of the high wear resistance of the film surface and the residual compressive stress induced by shot peening.

  18. Eye Wear

    Science.gov (United States)

    Eye wear protects or corrects your vision. Examples are Sunglasses Safety goggles Glasses (also called eyeglasses) Contact ... jobs and some sports carry a risk of eye injury. Thousands of children and adults get eye ...

  19. Fretting fatigue crack propagation rate under variable loading conditions

    Directory of Open Access Journals (Sweden)

    C. Gandiolle

    2016-01-01

    Full Text Available Fretting fatigue experiments aim to represent industrial problems and most of them endure variable loading. Being able to assess lifetime of assemblies, especially for low propagation rate conditions, is essential as experimental validation is often too expensive. Both experimental and numerical approaches are proposed to follow the crack propagation rate of steel on steel cylinder/plane fretting fatigue contact submitted to variable loading conditions. An original experimental monitoring has been implemented on the fretting-fatigue test device to observe crack propagation using a potential drop technique. A calibration curve relating crack length and electrical potential was established for the studied contact. It allows direct knowledge of the crack length and crack propagation rate. It was applied to mixed load test showing crack arrest for the last loading condition. To explain this behavior, a 2-dimensional FE modeling was implemented to simulate the complexes multi-axial contact stressing. The crack propagation rate was formalized using an effective stress intensity factor amplitude ΔKeff coupled with Paris law of the material. The crack arrest condition for a given loading was related to ΔKeff along the expected crack path crossing the material crack arrest threshold ΔK0. The failure was related to ΔKeff reaching the critical stress intensity factor KIC. A good correlation with experiments was observed allowing to predict the crack arrest condition although the model tends to overestimate the final crack length extension.

  20. 击发装置关重件磨损特性分析及失效寿命预测%Wearing Characteristics Analysis and Failure Life Forecast of Key Components in Gun Firing Mechanism

    Institute of Scientific and Technical Information of China (English)

    胡慧斌; 侯小锋; 曹立军; 马吉胜

    2014-01-01

    The recocking latch and the cocking cam shaft are the key components of gun breech-block firing mechanism.Wearing between the recocking latch bearing arm and the cocking cam shaft bearing arm is the usual failure reason that is difficult or impossible to open the breech-block.To timely and effectively realize the preventive maintenance,a new kind of wear failure life forecast method was put forward based on friction-wear test and virtual prototype.Their material PCrNiMo steel was used to fabricate pin samples and disk samples.The friction-wear tests were carried out based on MMS-1 G pin-on-disk tester to deeply study the friction-wear characteristics,and explore the surface wear mechanism and fit the wear failure rules under conditions of high-speed,heavy load and dry-sliding friction.Virtual prototype of gun firing device was established in environment of Pro/E and ADAMS to simulate the load spectrums of the recocking latch bearing arm and the cocking cam shaft bearing arm during the process of au-tomatic breechblock opening and closing.Their wear failure lives were forecasted based on out-line discretization and reconstruction,the results can provide the sufficient decision basis for preventive maintenance.%复拨器拨动子和拨动子轴是炮闩击发装置的关键零部件。复拨器拨动子支臂和拨动子轴支臂作用处磨损是导致不能开闩故障的常见原因。为了实现及时有效的预防性维修,采用其材料 PCrNiMo 钢制作销试样和盘试样,在 MMS 1 G型销盘式摩擦磨损试验机上进行摩擦磨损试验,研究高速、高载、干滑动摩擦条件下的摩擦磨损特性与表面磨损机制,拟合得到磨损失效规律。在 Pro/E 和 ADAMS环境下建立炮闩虚拟样机,基于动力学仿真获取复拨器拨动子支臂和拨动子轴支臂在自动开闩时的载荷谱,通过零部件外廓的离散化和外廓重构,预测其磨损失效寿命,为实现预防性维修提供决策依据。

  1. Failure analysis of a kind of low power connector

    Institute of Scientific and Technical Information of China (English)

    ZHOU Yi-lin; ZENG Ning; XU Liang-jun; J(O)RGENS Stefan

    2007-01-01

    A kind of low power connector used e.g. in household appliances was partly burned in routine experiment. The heat sources were four paralleled contacts constructed by springs (Sn/CuSn-alloy) in socket and a plug sheet (Ni/Steel) while mating. The contact interfaces were detected by scanning electronic microscope (SEM) and X-ray energy dispersive spectroscopy (XEDS), obvious wear tracks and various contaminants, including element Si, Al, Na, K, S, C1, O, etc., were found. The contamination degrees on the four paralleled contacts .were different, so that the ratio of average contact resistance on the four contacts was about 5:8:3:1. The maximum contact resistance on contacts of the plug sheet reached 28 Ω. The main failure reasons were fretting and contamination between the contact interfaces. Fretting simulation showed that connection resistance of connectors was raised up, even to ohms level. When the current increased to 5 A, the socket housing was heated and decomposed. By the thermal analysis, it was estimated that the connector would be burned under the lower current if the current was not evenly distributed on the four paralleled contacts caused by uneven contamination. Improvement methods for connector failure are also discussed.

  2. Understanding and modeling Förster-type resonance energy transfer (FRET) introduction to FRET

    CERN Document Server

    Govorov, Alexander; Demir, Hilmi Volkan

    2016-01-01

    This Brief presents a historical overview of the Förster-type nonradiative energy transfer and a compilation of important progress in FRET research, starting from Förster until today, along with a summary of the current state-of-the-art. Here the objective is to provide the reader with a complete account of important milestones in FRET studies and FRET applications as well as a picture of the current status.

  3. Analysis of Fretting Fatigue Strength of Integral Shroud Blade for Steam Turbine

    Science.gov (United States)

    Kaneko, Yasutomo; Tomii, Masayuki; Ohyama, Hiroharu; Kurimura, Takayuki

    To improve the reliability and the thermal efficiency of LP (Low Pressure) end blades of steam turbine, new standard series of LP end blades have been developed. The new LP end blades are characterized by the ISB (Integral Shroud Blade) structure. In the ISB structure, blades are continuously coupled by blade untwist due to centrifugal force when the blades rotate at high speed. One of the probable failure modes of the ISB structure seems to be fretting fatigue, because the ISB utilizes friction damping between adjacent shrouds and stubs. Therefore, in order to design a blade with high reliability, the design procedure for evaluating the fretting fatigue strength was established by the model test and the nonlinear contact analysis. This paper presents the practical design method for predicting the fretting fatigue strength of the ISB structure, and the some applications are explained.

  4. Intelligent Detection of Drill Wear

    Science.gov (United States)

    Liu, T. I.; Chen, W. Y.; Anatharaman, K. S.

    1998-11-01

    Backpropagation neural networks (BPNs) were used for on-line detection of drill wear. The neural network consisted of three layers: input, hidden, and output. The input vector comprised drill size, feed rate, spindle speed, and eight features obtained by processing the thrust and torque signals. The output was the drill wear state which either usable or failure. Drilling experiments with various drill sizes, feed rates and spindle speeds were carried out. The learning process was performed effectively by utilising backpropagation with smoothing and an activation function slope. The on-line detection of drill wear states using BPNs achieved 100% reliability even when the drill size, feed rate and spindle speed were changed. In other words, the developed on-line drill wear detection systems have very high robustness and hence can be used in very complex production environments, such as flexible manufacturing systems.

  5. Tooth wear

    Directory of Open Access Journals (Sweden)

    Tušek Ivan

    2014-01-01

    Full Text Available Tooth wear is the loss of dental hard tissue that was not caused by decay and represents a common clinical problem of modern man. In the etiology of dental hard tissue lesions there are three dominant mechanisms that may act synergistically or separately:friction (friction, which is caused by abrasion of exogenous, or attrition of endogenous origin, chemical dissolution of dental hard tissues caused by erosion, occlusal stress created by compression and flexion and tension that leads to tooth abfraction and microfracture. Wear of tooth surfaces due to the presence of microscopic imperfections of tooth surfaces is clinically manifested as sanding veneers. Tribology, as an interdisciplinary study of the mechanisms of friction, wear and lubrication at the ultrastructural level, has defined a universal model according to which the etiopathogenesis of tooth wear is caused by the following factors: health and diseases of the digestive tract, oral hygiene, eating habits, poor oral habits, bruxism, temporomandibular disorders and iatrogenic factors. Attrition and dental erosion are much more common in children with special needs (Down syndrome. Erosion of teeth usually results from diseases of the digestive tract that lead to gastroesophageal reflux (GER of gastric juice (HCl. There are two basic approaches to the assessment of the degree of wear and dental erosion. Depending on the type of wear (erosion, attrition, abfraction, the amount of calcium that was realised during the erosive attack could be determined qualitatively and quantitatively, or changes in optical properties and hardness of enamel could be recorded, too. Abrasion of teeth (abrasio dentium is the loss of dental hard tissue caused by friction between the teeth and exogenous foreign substance. It is most commonly provoked by prosthetic dentures and bad habits, while its effect depends on the size of abrasive particles and their amount, abrasive particle hardness and hardness of tooth

  6. A View on Wear Mechanism of Metallic Card Clothing

    Institute of Scientific and Technical Information of China (English)

    WU Liang; WANG Wen-qiang; NI Huai-sheng

    2008-01-01

    The wear mechanism of metallic card clothing,used in textile industry, was analyzed. A fast wear test for metallic card clothing racks was developed, which was used as collecting the wear metal particles. The failure type of card clothing was analyzed by the mean of scanning electron microscopy (SEM) and ferro-spectrum technology. The results show that the main wear mechanism of metallic card clothing is low load and high repetition interval fatigue wear caused by friction force between fiber and metal wire teeth.The appropriate quenching microstmcture, which improves the wear resistance of the metallic card clothing rack is also discussed.

  7. Action-FRET of a Gaseous Protein

    Science.gov (United States)

    Daly, Steven; Knight, Geoffrey; Halim, Mohamed Abdul; Kulesza, Alexander; Choi, Chang Min; Chirot, Fabien; MacAleese, Luke; Antoine, Rodolphe; Dugourd, Philippe

    2017-01-01

    Mass spectrometry is an extremely powerful technique for analysis of biological molecules, in particular proteins. One aspect that has been contentious is how much native solution-phase structure is preserved upon transposition to the gas phase by soft ionization methods such as electrospray ionization. To address this question—and thus further develop mass spectrometry as a tool for structural biology—structure-sensitive techniques must be developed to probe the gas-phase conformations of proteins. Here, we report Förster resonance energy transfer (FRET) measurements on a ubiquitin mutant using specific photofragmentation as a reporter of the FRET efficiency. The FRET data is interpreted in the context of circular dichroism, molecular dynamics simulation, and ion mobility data. Both the dependence of the FRET efficiency on the charge state—where a systematic decrease is observed—and on methanol concentration are considered. In the latter case, a decrease in FRET efficiency with methanol concentration is taken as evidence that the conformational ensemble of gaseous protein cations retains a memory of the solution phase conformational ensemble upon electrospray ionization.

  8. FRET in membrane biophysics: an overview

    Directory of Open Access Journals (Sweden)

    Luis MS Loura

    2011-11-01

    Full Text Available Förster resonance energy transfer (FRET, in most applications used as a spectroscopicruler, allows an easy determination of the donor-acceptor intermolecular distance.However, the situation becomes complex in membranes, since around each donor there isan ensemble of acceptors at non-correlated distances. In this review, state-of-the-artmethodologies for this situation are presented, usually involving time-resolved data andmodel fitting. This powerful approach can be used to study the occurrence of phaseseparation (rafts or other type of domains, allowing their detection as well as sizeevaluation. Formalisms for studying lipid-protein and protein-protein interactionsaccording to specific topologies are also addressed. The advantages and addedcomplexity of a specific type of FRET (energy homo-transfer or energy migration aredescribed, as well as applications of FRET under the microscope.

  9. Single Molecule Sensitive FRET in Attoliter Droplets

    CERN Document Server

    Milas, Peker; Gamari, Ben D; Goldner, Lori S

    2013-01-01

    Single molecular-pair fluorescence resonance energy transfer (spFRET) has become an cross-disciplinary tool for understanding molecular folding and interactions. While providing detailed information about the individual members of a molecular ensemble, this technique is always limited by fluorophore brightness and stability. In the case of diffusing molecules, the experiment is further limited by the number of photons that can be collected during the time it takes for a molecule to diffuse across the detection volume. To maximize the number of photons it is common to either increase the detection volume at the expense of increased background, or increase the diffusion time by adding glycerol or sucrose to increase viscosity. Here we demonstrate that FRET from attoliter volume (100 nm radius) aqueous droplets in perfluorinated oil has significantly higher signal-to-noise and a much wider dynamic range than FRET from molecules diffusing in solution. However, our measurements also reveal a droplet environment th...

  10. Multiscale Modeling of Wear Degradation

    KAUST Repository

    Moraes, Alvaro

    2014-01-06

    Cylinder liners of diesel engines used for marine propulsion are naturally subjected to a wear process, and may fail when their wear exceeds a specified limit. Since failures often represent high economical costs, it is utterly important to predict and avoid them. In this work [4], we model the wear process using a pure jump process. Therefore, the inference goal here is to estimate: the number of possible jumps, its sizes, the coefficients and the shapes of the jump intensities. We propose a multiscale approach for the inference problem that can be seen as an indirect inference scheme. We found that using a Gaussian approximation based on moment expansions, it is possible to accurately estimate the jump intensities and the jump amplitudes. We obtained results equivalent to the state of the art but using a simpler and less expensive approach.

  11. Multiscale Modeling of Wear Degradation

    KAUST Repository

    Moraes, Alvaro

    2016-01-06

    Cylinder liners of diesel engines used for marine propulsion are naturally subjected to a wear process, and may fail when their wear exceeds a specified limit. Since failures often represent high economical costs, it is utterly important to predict and avoid them. In this work [4], we model the wear process using a pure jump process. Therefore, the inference goal here is to estimate: the number of possible jumps, its sizes, the coefficients and the shapes of the jump intensities. We propose a multiscale approach for the inference problem that can be seen as an indirect inference scheme. We found that using a Gaussian approximation based on moment expansions, it is possible to accurately estimate the jump intensities and the jump amplitudes. We obtained results equivalent to the state of the art but using a simpler and less expensive approach.

  12. Multiscale Modeling of Wear Degradation

    KAUST Repository

    Moraes, Alvaro

    2015-01-07

    Cylinder liners of diesel engines used for marine propulsion are naturally subjected to a wear process, and may fail when their wear exceeds a specified limit. Since failures often represent high economical costs, it is utterly important to predict and avoid them. In this work [4], we model the wear process using a pure jump process. Therefore, the inference goal here is to estimate: the number of possible jumps, its sizes, the coefficients and the shapes of the jump intensities. We propose a multiscale approach for the inference problem that can be seen as an indirect inference scheme. We found that using a Gaussian approximation based on moment expansions, it is possible to accurately estimate the jump intensities and the jump amplitudes. We obtained results equivalent to the state of the art but using a simpler and less expensive approach.

  13. Investigation on the Tribological Behavior and Wear Mechanism of Five Different Veneering Porcelains.

    Directory of Open Access Journals (Sweden)

    Jie Min

    Full Text Available The primary aim of this research was to investigate the wear behavior and wear mechanism of five different veneering porcelains.Five kinds of veneering porcelains were selected in this research. The surface microhardness of all the samples was measured with a microhardness tester. Wear tests were performed on a ball-on-flat PLINT fretting wear machine, with lubrication of artificial saliva at 37°C. The friction coefficients were recorded by the testing system. The microstructure features, wear volume, and damage morphologies were recorded and analyzed with a confocal laser scanning microscope and a scanning electron microscope. The wear mechanism was then elucidated.The friction coefficients of the five veneering porcelains differ significantly. No significant correlation between hardness and wear volume was found for these veneering porcelains. Under lubrication of artificial saliva, the porcelain with higher leucite crystal content exhibited greater wear resistance. Additionally, leucite crystal size and distribution in glass matrix influenced wear behavior. The wear mechanisms for these porcelains were similar: abrasive wear dominates the early stage, whereas delamination was the main damage mode at the later stage. Furthermore, delamination was more prominent for porcelains with larger crystal sizes.Wear compatibility between porcelain and natural teeth is important for dental restorative materials. Investigation on crystal content, size, and distribution in glass matrix can provide insight for the selection of dental porcelains in clinical settings.

  14. CASL Structural Mechanics Modeling of Grid-to-Rod Fretting (GTRF)

    Science.gov (United States)

    Lu, Wei; Thouless, M. D.; Hu, Zupan; Wang, Hai; Ghelichi, Ramin; Wu, Chen-Hung; Kamrin, Ken; Parks, David

    2016-09-01

    Fluid-induced grid-to-rod fretting (GTRF) wear is responsible for over 70% of fuel leaks in pressurized water reactors (PWRs) in the US. The Consortium for Advanced Simulation of Light Water Reactors (CASL) has identified GTRF as a challenge problem that is very important to nuclear plants. GTRF is a complex problem that involves multiple physical phenomena. This paper summarizes several GTRF-related problems being addressed by the University of Michigan and the Massachusetts Institute of Technology, CASL partners. These include analyses of cladding creep, wear, structural mechanics, and the effects of the rod-to-grid gap. Also outlined are additional aspects of material science and computational modeling that will be needed to realize the ultimate goal of high-fidelity predictive modeling and design tools to address GTRF.

  15. CTAB enhancement of FRET in DNA structures.

    Science.gov (United States)

    Oh, Taeseok; Takahashi, Tsukasa; Kim, Sejung; Heller, Michael J

    2016-01-01

    The effect of cetyl-trimethylammonium bromide (CTAB) on enhancing the fluorescence resonance energy transfer (FRET) between two dye-conjugated DNA strands was studied using fluorescence emission spectroscopy and dynamic light scattering (DLS). For hybridized DNA where one strand is conjugated with a TAMRA donor and the other with a TexasRed acceptor, increasing the concentration of CTAB changes the fluorescence emission properties and improves the FRET transfer efficiency through changes in the polarity of the solvent, neutralization of the DNA backbone and micelle formation. For the DNA FRET system without CTAB, the DNA hybridization leads to contact quenching between TAMRA donor and TexasRed acceptor producing reduced donor emission and only a small increase in acceptor emission. At 50 µM CTAB, however, the sheathing and neutralization of the dye-conjugated dsDNA structure significantly reduces quenching by DNA bases and dye interactions, producing a large increase in FRET efficiency, which is almost four fold higher than without CTAB.

  16. Failure analysis on surface wear of 20CrMnTi steel camshaft%20 CrMnTi钢凸轮轴表面磨损失效分析

    Institute of Scientific and Technical Information of China (English)

    焦丽; 葛保红; 张燕明; 徐向阳; 孙思东

    2015-01-01

    Wear cause of the 20CrMnTi steel monoblock pump camshaft was analyzed by means of macroscopic examination, lubricating oil property test, chemical compositions analysis, mechanical property test, metallographic examination and microhardness test.The results show that the main reason for the surface wear of the camshaft is attributed to the hard and brittle blocky and network carbide in the surface layer which reduces the contact fatigue strength of the camshaft journals and increases the probability of the spalling along grain boundary. Secondly, the secondary quenched martensite after grinding leads to the crack and brittle spalling on the basis of the structure defects.The spalled particles are play intensive abrasion role and lead to the early wear failure of the monoblock pump camshaft.%采用宏观检验、润滑油油品性能测试、化学成分分析、力学性能测试、金相检验和显微硬度测试等手段对20CrMnTi钢单体泵凸轮轴表面磨损失效的原因进行了分析。结果表明,造成该凸轮轴表面磨损的主要原因是,凸轮轴表层组织中硬而脆的块状及网状碳化物降低了轴颈表面的接触疲劳强度,加大了其沿晶剥落的可能性。其次,磨削二次淬火马氏体的出现,在迭加了上述组织缺陷的基础上,产生了裂纹和脆性剥落。剥落的颗粒成为磨粒参与磨削,导致凸轮轴早期磨损失效。

  17. Friction Induced Wear of Rapid Prototyping Generated Materials: A Review

    Directory of Open Access Journals (Sweden)

    A. Tsouknidas

    2011-01-01

    Full Text Available Additive manufacturing has been introduced in the early 80s and has gained importance as a manufacturing process ever since. Even though the inception of the implicated processes predominantly focused on prototyping purposes, during the last years rapid prototyping (RP has emerged as a key enabling technology for the fabrication of highly customized, functionally gradient materials. This paper reviews friction-related wear phenomena and the corresponding deterioration mechanisms of RP-generated components as well as the potential of improving the implicated materials' wear resistance without significantly altering the process itself. The paper briefly introduces the concept of RP technologies and the implicated materials, as a premises to the process-dependent wear progression of the generated components for various degeneration scenarios (dry sliding, fretting, etc..

  18. Anomalous surplus energy transfer observed with multiple FRET acceptors.

    Directory of Open Access Journals (Sweden)

    Srinagesh V Koushik

    Full Text Available BACKGROUND: Förster resonance energy transfer (FRET is a mechanism where energy is transferred from an excited donor fluorophore to adjacent chromophores via non-radiative dipole-dipole interactions. FRET theory primarily considers the interactions of a single donor-acceptor pair. Unfortunately, it is rarely known if only a single acceptor is present in a molecular complex. Thus, the use of FRET as a tool for measuring protein-protein interactions inside living cells requires an understanding of how FRET changes with multiple acceptors. When multiple FRET acceptors are present it is assumed that a quantum of energy is either released from the donor, or transferred in toto to only one of the acceptors present. The rate of energy transfer between the donor and a specific acceptor (k(D-->A can be measured in the absence of other acceptors, and these individual FRET transfer rates can be used to predict the ensemble FRET efficiency using a simple kinetic model where the sum of all FRET transfer rates is divided by the sum of all radiative and non-radiative transfer rates. METHODOLOGY/PRINCIPAL FINDINGS: The generality of this approach was tested by measuring the ensemble FRET efficiency in two constructs, each containing a single fluorescent-protein donor (Cerulean and either two or three FRET acceptors (Venus. FRET transfer rates between individual donor-acceptor pairs within these constructs were calculated from FRET efficiencies measured after systematically introducing point mutations to eliminate all other acceptors. We find that the amount of energy transfer observed in constructs having multiple acceptors is significantly greater than the FRET efficiency predicted from the sum of the individual donor to acceptor transfer rates. CONCLUSIONS/SIGNIFICANCE: We conclude that either an additional energy transfer pathway exists when multiple acceptors are present, or that a theoretical assumption on which the kinetic model prediction is based is

  19. FRET and Non-FRET processes in quantum dot - dye nanoassemblies

    Energy Technology Data Exchange (ETDEWEB)

    Kowerko, Danny; Schuster, Joerg; Borczyskowski, Christian von [Center of Nanostructured Materials and Analytics, TU-Chemnitz, 09107 Chemnitz (Germany)

    2009-07-01

    Assemblies of semiconductor quantum dots (QDs - donor) and organic (dye - acceptor) molecules are of increasing interest for numerous applications in science and technology. Recent publications on such systems report on charge and fluorescence resonant energy transfer (FRET), prevalently neglecting an exact quantitative spectroscopic analysis of the acceptor. Recently, calculations of Seifert et al. and Blaudeck and coworkers demonstrated the crucial dependence of trap state emission from the surface coverage. In our contribution we emphasize the role of dye induces surface trap states as one mechanism - besides FRET - for QD quenching. Thus detailed quantitative analysis of titration experiments of differently functionalized perylenebismide molecules and CdSe/ZnS quantum dots will be discussed. By means of single particle spectroscopy we may even compare spectroscopic properties of the free and bound species on one and the same sample under identical conditions. Furthermore, analysis of FRET allows for a distinction between different geometries of the dye-QD assemblies.

  20. Distribution Characteristics of Wear Particles from Material of Machine Elements in Lubricant condition

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yon Sang; Jun, Sung Jae; Kim, Young Hee; Park, Heung Sik [Donga Univ., Busan (Korea, Republic of)

    2007-07-01

    It necessarily follows that wear particles are generated through a friction and wear in a mechanical moving system. The wear particles are relative to the failure and the life of machine elements directly. To analyze the wear particle, its shape characteristics were calculated quantitative values such as diameter, roundness and fractal parameters by digital image processing. In this study, the histograms of shape parameters of wear particles were used for the purpose of analyzing the distribution of wear particles in various conditions. We consider that the histogram of shape parameter can be effectively represented to study a wear mechanism.

  1. Discrimination between FRET and non-FRET quenching in a photochromic CdSe quantum dot/dithienylethene dye system

    Science.gov (United States)

    Dworak, Lars; Reuss, Andreas J.; Zastrow, Marc; Rück-Braun, Karola; Wachtveitl, Josef

    2014-11-01

    A photochromic Förster resonance energy transfer (FRET) system was employed to disentangle the fluorescence quenching mechanisms in quantum dot/photochromic dye hybrids. In the off-state of the dye the main quenching mechanism is FRET whereas the moderate quenching in the on-state is due to non-FRET pathways opened up upon assembly.A photochromic Förster resonance energy transfer (FRET) system was employed to disentangle the fluorescence quenching mechanisms in quantum dot/photochromic dye hybrids. In the off-state of the dye the main quenching mechanism is FRET whereas the moderate quenching in the on-state is due to non-FRET pathways opened up upon assembly. Electronic supplementary information (ESI) available: QD and DTE synthesis, preparation of the DTE/QD coupled system, TEM image of the nanocrystals and experimental details. See DOI: 10.1039/c4nr05144k

  2. Wearing gloves in the hospital

    Science.gov (United States)

    ... gloves; PPE - wearing gloves; Nosocomial infection - wearing gloves; Hospital acquired infection - wearing gloves ... Wearing gloves in the hospital helps prevent the spread of germs. This helps protect both patients and health care workers from infection.

  3. Comparative wear mapping techniques

    DEFF Research Database (Denmark)

    Alcock, J.; Sørensen, Ole Toft; Jensen, S.

    1996-01-01

    Pin-on-disc tests of tungsten carbide pins against silicon carbide discs were performed and wear rate, mechanism and friction maps constructed. Correlations were observed between the wear mode and the friction of the pin-disc interface, and between the qualitative incidence of disruptive wear...

  4. Wear Debris Analysis:Fundamental Principle of Wear-Graphy

    Institute of Scientific and Technical Information of China (English)

    陈铭; 王伟华; 殷勇辉; 王成焘

    2004-01-01

    A new wear-graphy technology was developed, which can simultaneously identify the shape and composition of wear debris, for both metals and non-metals.The fundamental principles of the wear-graphy system and its wear-gram system are discussed here.A method was developed to distribute wear debris on a slide uniformly to reduce overlapping of wear debris while smearing.The composition identification analyzes the wear debris using the scanning electron microscope (SEM) energy spectrum, infrared-thermal imaging and X-ray imaging technology.A wear debris analysis system based on database techniques is demonstrated, and a visible digitized wear-gram is acquired based on the information of wear debris with image collection and processing of the wear debris.The method gives the morphological characteristics of the wear debris, material composition identification of the wear debris, intelligent recognition of the wear debris, and storage and management of wear debris information.

  5. Fault Wear and Friction Evolution: Experimental Analysis

    Science.gov (United States)

    Boneh, Y.; Chang, J. C.; Lockner, D. A.; Reches, Z.

    2011-12-01

    -state stage is characterized by (1) relatively low wear-rate (approximately 10% of running-in wear-rate) and (2) quasi-constant friction coefficient. These observations suggest only small changes in the gouge layer in term of thickness (100 to 200 microns) and strength in this final stage. The present study indicates that (1) wear by plowing and asperity failure initiate early, during the first few millimeters of slip; and (2) wear and associated gouge formation appear as the controlling factors of friction evolution and fault weakening.

  6. Single molecule FRET data analysis procedures for FRET efficiency determination: probing the conformations of nucleic acid structures.

    Science.gov (United States)

    Krüger, Asger Christian; Birkedal, Victoria

    2013-11-01

    Single molecule FRET microscopy is an attractive technique for studying structural dynamics and conformational diversity of nucleic acid structures. Some of its strengths are that it can follow structural changes on a fast time scale and identify conformation distributions arising from dynamic or static population heterogeneity. Here, we give a description of the experiment and data analysis procedures of this method and detail what parameters are needed for FRET efficiency calculation. Using single molecule FRET data obtained on G-quadruplex DNA structures that exhibit large conformation diversity, we illustrate that the shape of the FRET distribution changes depending on what parameters are included in the data analysis procedure.

  7. In silico FRET from simulated dye dynamics

    Science.gov (United States)

    Hoefling, Martin; Grubmüller, Helmut

    2013-03-01

    Single molecule fluorescence resonance energy transfer (smFRET) experiments probe molecular distances on the nanometer scale. In such experiments, distances are recorded from FRET transfer efficiencies via the Förster formula, E=1/(1+(). The energy transfer however also depends on the mutual orientation of the two dyes used as distance reporter. Since this information is typically inaccessible in FRET experiments, one has to rely on approximations, which reduce the accuracy of these distance measurements. A common approximation is an isotropic and uncorrelated dye orientation distribution. To assess the impact of such approximations, we present the algorithms and implementation of a computational toolkit for the simulation of smFRET on the basis of molecular dynamics (MD) trajectory ensembles. In this study, the dye orientation dynamics, which are used to determine dynamic FRET efficiencies, are extracted from MD simulations. In a subsequent step, photons and bursts are generated using a Monte Carlo algorithm. The application of the developed toolkit on a poly-proline system demonstrated good agreement between smFRET simulations and experimental results and therefore confirms our computational method. Furthermore, it enabled the identification of the structural basis of measured heterogeneity. The presented computational toolkit is written in Python, available as open-source, applicable to arbitrary systems and can easily be extended and adapted to further problems. Catalogue identifier: AENV_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AENV_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: GPLv3, the bundled SIMD friendly Mersenne twister implementation [1] is provided under the SFMT-License. No. of lines in distributed program, including test data, etc.: 317880 No. of bytes in distributed program, including test data, etc.: 54774217 Distribution format: tar.gz Programming language

  8. 45号钢微动疲劳门坎值特性研究%Research on 45-carbon steel fretting fatigue damage threshold properties

    Institute of Scientific and Technical Information of China (English)

    邢海军; 赵颖娣; 俞新宇; 苏彬; 孙伟明

    2011-01-01

    The fretting fatigue damage threshold studies were conducted on 45-carbon steel through interrupted fretting fatigue tests, and the relationship between the contact surface crack characteristics and the number of fretting wear cycles was also investigated. There exists a fretting fatigue damage threshold on 45-carbon steel, when the number of fretting wear cycles is over the threshold value cycles, the fatigue life of the specimen will be decreased significantly. The damage levels were calculated as a percentage of the total cycles with fretting for 100% of its life to fracture for the baseline fretting fatigue specimen. The value of the threshold is in the range of 20%~40%. The threshold value remains the unchanged with changing the conditions of the load on specimens. Microscopic observation shows that there were obvious long cracks on the contact surface when the fretting cycles were more than the threshold value.%通过中断性试验研究了45号钢的微动疲劳门坎值,并对不同微动次数下接触面的裂纹特征进行了观察.试验测得45号钢显著存在一个微动疲劳门坎值,微动次数直至超过微动疲劳门坎值时,微动才会使试样疲劳寿命显著下降.以试样上预定的微动循环次数与全微动下试样疲劳基准寿命的比值表示,其微动疲劳门坎值大约在20%~40%范围内.改变载荷条件,该门坎值仍保持在20%~40%范围内;显微观察显示,在微动循环次数超过门坎值之后,在接触磨损面上几乎都能观察到明显的大裂纹.

  9. Fretting corrosion behavior of nitinol spinal rods in conjunction with titanium pedicle screws.

    Science.gov (United States)

    Lukina, Elena; Kollerov, Mikhail; Meswania, Jay; Khon, Alla; Panin, Pavel; Blunn, Gordon W

    2017-03-01

    Untypical corrosion damage including erosions combined with the build-up of titanium oxide as a corrosion product on the surface of explanted Nitinol spinal rods in the areas where it was in contact with titanium pedicle screw head is reported. It was suggested that Nitinol rods might have inferior fretting corrosion resistance compared with that made of titanium or CoCr. Fretting corrosion of Nitinol spinal rods with titanium (Ti6Al4V) pedicle screws were tested in-vitro by conducting a series of potentiostatic measurements of the peak-to-peak values of fretting corrosion current under bending in a 10% solution of calf serum in PBS. The test included Nitinol rods locked in titanium pedicle screws of different designs. Performance of commercially available titanium (Ti6Al4V) and CoCr spinal rods was also investigated for a comparison. Corrosion damage observed after the in-vitro tests was studied using SEM and EDAX analysis and was compared with patterns on Nitinol rods retrieved 12months after initial surgery. Metal ions level was measured in the test media after in-vitro experiments and in the blood and tissues of the patients who had the rods explanted. The results of this study revealed that Nitinol spinal rods locked in Ti pedicle screws are susceptible to fretting corrosion demonstrating higher fretting corrosion current compared with commercially used Ti6Al4V and CoCr rods. On the surface of Nitinol rods after in-vitro tests and on those retrieved from the patients similar corrosion patterns were observed. Improved resistance to fretting corrosion was observed with Nitinol rods in the in-vitro tests where pedicle screws were used with a stiffer locking mechanism. Since the development of the localized corrosion damage might increase the risk of premature fatigue failure of the rods and result in leaching of Ni ions, it is concluded that Nitinol rods should not be used in conjunction with Ti pedicle screws without special protection especially where the

  10. Fret Replica Inspection Laser Scanner (FRILS)

    Energy Technology Data Exchange (ETDEWEB)

    Kretz, S.; Hanley, K., E-mail: steve.kretz@opg.com, E-mail: kelly.hanley@opg.com [Ontario Power Generation, Inspection Maintenance and Commercial Services, Pickering, Ontario (Canada)

    2008-07-01

    In the stress analysis of flaws and artifacts found in pressure tubes, it is crucial to have detailed knowledge of the flaw geometry. Fuel channel inspections by ultrasonic or eddy current inspection methods alone cannot provide the complete required geometry information. Replicas, which are a negative impression of surface pressure tube indications, are scanned with a laser system which will provide the additional detail required. FRILS was initially developed in 1993 to establish in-house capability of profiling indications on the inside diameter surface of pressure tubes. The need of this profiling was initially a response to the discovery of fuel bundle bearing pad fretting (FBBPF) caused by flow induced fuel bundle vibration. The benefits of the system were soon realized as a tool for profiling debris type indications. Although the primary use of FRILS is to profile FBBBF and Debris Fretting, since its inception the FRILS inspection system has become an instrumental tool in flaw assessment for: Fuel Bundle Bearing Pad Frets (FBBPF); Debris Frets; Scratches; Crevice Corrosion; Oxide Jacking; Areas of surface roughness; and, Weld Profiling. Replicas are collected via acquisition from tooling on both the Channel and Gauging Apparatus for Reactors (CIGAR) and the Advanced Non-Destructive Examination (ANDE) systems. The ANDE system is a high speed data acquisition system which includes both an ultrasonic inspection tool and a replication tool. Although both of these tools were designed to be delivered with the UDM, the platform for these tools was built with flexibility allowing for adoption to other delivery systems. These tools were based on the experience of the CIGAR inspection system. The CIGAR system has also undergone many system upgrades resulting in reduced inspection times. The FRILS system - Fret Replication Inspection Laser Scanner system was developed and has been upgraded to meet the demands of the improved inspection and replication systems. FRILS

  11. BOBA FRET: bootstrap-based analysis of single-molecule FRET data.

    Directory of Open Access Journals (Sweden)

    Sebastian L B König

    Full Text Available Time-binned single-molecule Förster resonance energy transfer (smFRET experiments with surface-tethered nucleic acids or proteins permit to follow folding and catalysis of single molecules in real-time. Due to the intrinsically low signal-to-noise ratio (SNR in smFRET time traces, research over the past years has focused on the development of new methods to extract discrete states (conformations from noisy data. However, limited observation time typically leads to pronounced cross-sample variability, i.e., single molecules display differences in the relative population of states and the corresponding conversion rates. Quantification of cross-sample variability is necessary to perform statistical testing in order to assess whether changes observed in response to an experimental parameter (metal ion concentration, the presence of a ligand, etc. are significant. However, such hypothesis testing has been disregarded to date, precluding robust biological interpretation. Here, we address this problem by a bootstrap-based approach to estimate the experimental variability. Simulated time traces are presented to assess the robustness of the algorithm in conjunction with approaches commonly used in thermodynamic and kinetic analysis of time-binned smFRET data. Furthermore, a pair of functionally important sequences derived from the self-cleaving group II intron Sc.ai5γ (d3'EBS1/IBS1 is used as a model system. Through statistical hypothesis testing, divalent metal ions are shown to have a statistically significant effect on both thermodynamic and kinetic aspects of their interaction. The Matlab source code used for analysis (bootstrap-based analysis of smFRET data, BOBA FRET, as well as a graphical user interface, is available via http://www.aci.uzh.ch/rna/.

  12. Large Scale Bacterial Colony Screening of Diversified FRET Biosensors.

    Directory of Open Access Journals (Sweden)

    Julia Litzlbauer

    Full Text Available Biosensors based on Förster Resonance Energy Transfer (FRET between fluorescent protein mutants have started to revolutionize physiology and biochemistry. However, many types of FRET biosensors show relatively small FRET changes, making measurements with these probes challenging when used under sub-optimal experimental conditions. Thus, a major effort in the field currently lies in designing new optimization strategies for these types of sensors. Here we describe procedures for optimizing FRET changes by large scale screening of mutant biosensor libraries in bacterial colonies. We describe optimization of biosensor expression, permeabilization of bacteria, software tools for analysis, and screening conditions. The procedures reported here may help in improving FRET changes in multiple suitable classes of biosensors.

  13. Ice and debris in the fretted terrain, Mars

    Science.gov (United States)

    Lucchitta, B. K.

    1984-01-01

    Viking moderate and high resolution images along the northern highland margin have been monoscopically and stereoscopically examined in order to study the development of fretted terrain. Young debris aprons around mesas and debris in tributary channels create typical fretted morphologies identical to ancient fretted morphologies. This suggests that the debris-apron process operating relatively recently also shaped the fretted terrain of the past. The debris aprons were lubricated by interstitial ice derived from ground ice. Abundant collapse features suggest that ground ice existed and may have flowed in places. The fretting process has been active for a long period and may be active today. The location of debris aprons in two latitudinal belts may be controlled by atmospheric conditions that permit ice in the region to remain in the ground below depths of about one meter and temperatures warm enough for ice to flow.

  14. ETP-0474: Evaluation of Electroless Nickel Coatings to Achieve Interference Fit in the RSRM Without Fretting

    Science.gov (United States)

    Schaffnit, William O.

    1997-01-01

    Part of the redesign of the SRMs for the Space Shuttle involved the substitution of three new capture cylinders for three of the previously used cylinders. These new cylinders mate with the old standard case segments in each of the three field joints. The new capture cylinders contain an integral capture latch on the tang end which mates with a case clevis during stackup at KSC. The capture cylinders also contain a groove in the capture latch to provide for a third 0-ring in the joint and are designed to achieve a metal-to- metal interference fit between the capture latch and the mating clevis. An unexpected fretting problem has occurred on the tang capture feature and the inner clevis leg interference fit surfaces on flight hardware since STS-26. Varying degrees of fretting damage have been found on the case segments from different flight motors. Fretting is a wear phenomena that occurs when two tightly fitting metal surfaces are subject to cyclic relative motion of extremely small amplitudes (generally less than 0.010-inch) in the absence of adequate lubrication. It is adhesive ("cold" - welding) in nature and vibration is its essential causative factor. This problem has manifested itself on the flight motors as a series of pits and axial gouges on the inside diameter (ID) surfaces of the inner clevis legs and the outside diameter (OD) surfaces of the tang capture features. The problem occurs in varying degrees of severity in all of the field joints. It is not believed that fretting is a flight safety issue. However, it could become a reusability issue if left unattended. Fretting has been encountered in other industries for many years and measures that will prevent or reduce it have been devised. These include: elimination or reduction of vibration (amplitudes and/or frequencies), elimination of slip, improved lubrication between parts, increased surface separation, increased interference, inducing residual compressive stresses in the surfaces of the mating

  15. Polymer wear evaluation

    DEFF Research Database (Denmark)

    Lagerbon, Mikkel; Sivebæk, Ion Marius

    2012-01-01

    the safety of the patients. Prediction of the wear of polymers is complicated by the low thermal conductivity of this kind of material. It implies that any acceleration of testing conditions by increased contact pressure and/or sliding velocity will make the polymer fail due to exaggerated heat buildup......Polymer wear plays an increasing role in manufacturing of machine parts for e.g. medical devices. Some of these have an expected lifetime of five to eight years during which very little wear of the components is acceptable. Too much wear compromises the dosage accuracy of the device and thereby....... This is not the kind of wear observed in medical devices. In the present work a method was developed capable of evaluating the wear progression in polymer-polymer contacts. The configuration of the setup is injection moulded specimens consisting of an upper part having a toroid shape and a lower flat part. The sliding...

  16. Polymer wear evaluation

    DEFF Research Database (Denmark)

    Lagerbon, Mikkel; Sivebæk, Ion Marius

    2012-01-01

    Polymer wear plays an increasing role in manufacturing of machine parts for e.g. medical devices. Some of these have an expected lifetime of five to eight years during which very little wear of the components is acceptable. Too much wear compromises the dosage accuracy of the device and thereby...... the safety of the patients. Prediction of the wear of polymers is complicated by the low thermal conductivity of this kind of material. It implies that any acceleration of testing conditions by increased contact pressure and/or sliding velocity will make the polymer fail due to exaggerated heat buildup....... This is not the kind of wear observed in medical devices. In the present work a method was developed capable of evaluating the wear progression in polymer-polymer contacts. The configuration of the setup is injection moulded specimens consisting of an upper part having a toroid shape and a lower flat part. The sliding...

  17. Wear of connector contacts exposed to relative motion

    Science.gov (United States)

    Wilk, R. A.

    Connectors play a significant role in the performance, cost, and reliability of electronic equipment. In connection with the development of the system interconnection design, a factor which is often overlooked is related to the importance of connector selection and mounting to minimize relative motion between contacts during vibration encountered in handling, transportation, and service. This motion can lead to the loss of protective coatings (gold and nickel) due to frictional wear. If this happens, fretting corrosion of the base metals may occur. The produced damage can adversely affect performance due to increased joint resistance, eventually causing intermittent contacts. The present investigation is concerned with the study of different style contacts (tuning fork, box, and circular) to determine their endurance and wear characteristics when exposed to relative motion created by vibration. All contacts investigated were fabricated from brass, beryllium copper, or phosphor bronze, and had .00127 mm minimum gold plating over .00127 mm minimum nickel plating.

  18. An investigation into failure analysis of interfering part of a steam turbine journal bearing

    Directory of Open Access Journals (Sweden)

    M. Mehdizadeh

    2014-10-01

    Full Text Available Journal bearings as so sensitive parts of steam turbines are very susceptible to failure through different mechanisms of wear, fatigue and crush during service conditions. Failure occurring through these mechanisms lead to turbine completely shut down as a result of interfering in working conditions of bearing different parts. In this research, failed interfered part of a journal bearing related to a 320,000 kW steam turbine was examined. Failure analysis investigations were performed by utilizing of stereographic, optical microscopy, scanning electron microscopy (SEM, energy-dispersive X-ray spectroscopy (EDS analysis and hardness test. Surface crush, large amounts of surface cracks, no noticeable changes of failed surface chemical composition and microstructure with significant hardness improvement were the main obtained results. The studies were revealed that the bearing part loosing and inappropriate clearance can produce relative displacements under cyclic gradient loading. This condition was detrimental for the service life of turbine journal bearing via failure through fretting fatigue mechanism.

  19. Wear Behavior of an Unstable Knee: Stabilization via Implant Design?

    Directory of Open Access Journals (Sweden)

    Jörn Reinders

    2014-01-01

    Full Text Available Background. Wear-related failures and instabilities are frequent failure mechanisms of total knee replacements. High-conforming designs may provide additional stability for the joint. This study analyzes the effects of a ligamentous insufficiency on the stability and the wear behavior of a high-conforming knee design. Methods. Two simulator wear tests were performed on a high-conforming total knee replacement design. In the first, a ligamentous-stable knee replacement with a sacrificed anterior cruciate ligament was simulated. In the second, a ligamentous-unstable knee with additionally insufficient posterior cruciate ligament and medial collateral ligament was simulated. Wear was determined gravimetrically and wear particles were analyzed. Implant kinematics was recorded during simulation. Results. Significantly higher wear rates (P≤0.001 were observed for the unstable knee (14.58±0.56 mg/106 cycles compared to the stable knee (7.97 ± 0.87 mg/106 cycles. A higher number of wear particles with only small differences in wear particle characteristics were observed. Under unstable knee conditions, kinematics increased significantly for translations and rotations (P≤0.01. This increase was mainly attributed to higher tibial posterior translation and internal rotations. Conclusion. Higher kinematics under unstable test conditions is a result of insufficient stabilization via implant design. Due to the higher kinematics, increased wear was observed in this study.

  20. Wear Modalities and Mechanisms of the Mining Non-asbestos Composite Brake Material

    Science.gov (United States)

    Bao, Jiusheng; Yin, Yan; Zhu, Zhencai; Tong, Minming; Lu, Yuhao; Peng, Yuxing

    2013-08-01

    The mining brake material is generally made of composite materials and its wear has important influences on the braking performance of disc brakes. In order to improve the braking reliability of mine hoisters, this paper did some tribological investigations on the mining brake material to reveal its wear modalities and mechanisms. The mining non-asbestos brake shoe and 16Mn steel were selected as braking pairs and tested on a pad-on-disc friction tester. And a SEM was used to observe the worn surface of the brake shoe. It is shown that the non-asbestos brake material has mainly five wear modalities: adhesive wear, abrasive wear, cutting wear, fatigue wear and high heat wear. At the front period of a single braking the wear modality is mainly composed of some light mechanical wear such as abrasive, cutting and point adhesive. With the temperature rising at the back period it transforms to some heavy mechanical wear such as piece adhesive and fatigue. While in several repeated brakings once the surface temperature rises beyond the thermal-decomposition point of the bonding material, the strong destructive high heat wear takes leading roles on the surface. And a phenomenon called friction catastrophe (FC) occurs easily, which as a result causes a braking failure. It is considered that the friction heat has important influences on the wear modalities of the brake material. And the reduction of friction heat must be an effective technical method for decreasing wear and avoiding braking failures.

  1. Understanding FRET as a Research Tool for Cellular Studies

    Directory of Open Access Journals (Sweden)

    Dilip Shrestha

    2015-03-01

    Full Text Available Communication of molecular species through dynamic association and/or dissociation at various cellular sites governs biological functions. Understanding these physiological processes require delineation of molecular events occurring at the level of individual complexes in a living cell. Among the few non-invasive approaches with nanometer resolution are methods based on Förster Resonance Energy Transfer (FRET. FRET is effective at a distance of 1–10 nm which is equivalent to the size of macromolecules, thus providing an unprecedented level of detail on molecular interactions. The emergence of fluorescent proteins and SNAP- and CLIP- tag proteins provided FRET with the capability to monitor changes in a molecular complex in real-time making it possible to establish the functional significance of the studied molecules in a native environment. Now, FRET is widely used in biological sciences, including the field of proteomics, signal transduction, diagnostics and drug development to address questions almost unimaginable with biochemical methods and conventional microscopies. However, the underlying physics of FRET often scares biologists. Therefore, in this review, our goal is to introduce FRET to non-physicists in a lucid manner. We will also discuss our contributions to various FRET methodologies based on microscopy and flow cytometry, while describing its application for determining the molecular heterogeneity of the plasma membrane in various cell types.

  2. ON ASSESSMNENT OF PHYSICAL WEAR IN ELEMENTS OF TECHNICAL DEVICES

    Directory of Open Access Journals (Sweden)

    S. N. Osipov

    2015-01-01

    Full Text Available Real assessment of wear in technical devices, construction structures, minings, their elements and connections is of great importance for provision of operational security and efficiency. Natural properties of the overwhelming majority of materials follow to probabilistic (stochastic laws due to various reasons (external influence, processing technologies and others. An assessment of physical wear rate of buildings and structures and their elements is carried out in the former republics of the USSR mainly in accordance with external physical signs (deflections, cracks, layer separations, etc. but wear percentage is often calculated on the basis of replacement cost in comparison with the initial one even without taking into account inflation which did not officially exist in the USSR. In this case destruction or failure of structure or their elements are considered as 100 % wear.The paper proposes a new methodology for assessment of physical wear rate in accordance with probability ratio of nofailure operation (reliability, minimum ratio is assigned to admissible limit value in conformity with technical requirements for the technical devices, construction structures, minings in question, their elements and connections. In this context minimum permissible wear probability (reliability is taken as 100 % wear rate and its initial index is considered as 0 % wear rate. That is why wear intensity in time depends on type of value probability distribution while determining the rate of physical property. The proposed methodology is intended for probabilistic wear assessment in case of relatively simple changes in strength properties of materials (for example, within the elastic limit.

  3. Intonation and Compensation of Fretted String Instruments

    CERN Document Server

    Varieschi, Gabriele U

    2009-01-01

    In this paper we present mathematical models and we analyze the physics related to the problem of intonation of musical instruments such as guitars, mandolins and similar, i.e., we study how to produce perfectly in tune notes on these instruments. This analysis begins with the correct fret placement on the instrument fingerboard, following precise mathematical laws, but then it becomes increasingly complicated due to the geometrical deformation of the strings when these instruments are played, and also due to the inharmonic characteristics of the same strings. As a consequence of these factors, perfect intonation of all the notes on the instrument can never be achieved, but complex compensation procedures are introduced and studied to minimize the problem. To test the validity of these compensation procedures, we have performed extensive measurements using standard monochord sonometers and other basic acoustical devices, which confirm the correctness of our theoretical models. In particular, these experimenta...

  4. Development and Validation of a Wear Model to Predict Polyethylene Wear in a Total Knee Arthroplasty: A Finite Element Analysis

    Directory of Open Access Journals (Sweden)

    Bernardo Innocenti

    2014-11-01

    Full Text Available Ultra-high molecular weight polyethylene (UHMWPE wear in total knee arthroplasty (TKA components is one of the main reasons of the failure of implants and the consequent necessity of a revision procedure. Experimental wear tests are commonly used to quantify polyethylene wear in an implant, but these procedures are quite expensive and time consuming. On the other hand, numerical models could be used to predict the results of a wear test in less time with less cost. This requires, however, that such a model is not only available, but also validated. Therefore, the aim of this study is to develop and validate a finite element methodology to be used for predicting polyethylene wear in TKAs. Initially, the wear model was calibrated using the results of an experimental roll-on-plane wear test. Afterwards, the developed wear model was applied to predict patello-femoral wear. Finally, the numerical model was validated by comparing the numerically-predicted wear, with experimental results achieving good agreement.

  5. QD-Based FRET Probes at a Glance

    Directory of Open Access Journals (Sweden)

    Armen Shamirian

    2015-06-01

    Full Text Available The unique optoelectronic properties of quantum dots (QDs give them significant advantages over traditional organic dyes, not only as fluorescent labels for bioimaging, but also as emissive sensing probes. QD sensors that function via manipulation of fluorescent resonance energy transfer (FRET are of special interest due to the multiple response mechanisms that may be utilized, which in turn imparts enhanced flexibility in their design. They may also function as ratiometric, or “color-changing” probes. In this review, we describe the fundamentals of FRET and provide examples of QD-FRET sensors as grouped by their response mechanisms such as link cleavage and structural rearrangement. An overview of early works, recent advances, and various models of QD-FRET sensors for the measurement of pH and oxygen, as well as the presence of metal ions and proteins such as enzymes, are also provided.

  6. An Experimental Study of Fretting of Gear Teeth

    Science.gov (United States)

    Krantz, Timothy L.

    2008-01-01

    Experiments were conducted to study fretting of gears. The gears were made from case-carburized AISI 9310 alloy to match the material of a flight actuator gearbox of interest. The objective of the testing was to produce damage representative of that observed on flight hardware. The following correlations and observations were noted. The amplitude of dithering motion very strongly influenced the type and magnitude of damage. Sliding amounts on the order of 30% of the width of the line contact were judged to most readily produce fretting damage. There was observed an incubation period on the order of tens-of-thousands of cycles, and the incubation period was influenced by surface roughness, torque, and the motion extent. Fretting damage could be produced for any of the torques tested, and the severity of damage increased slightly with torque. Gear teeth having surface roughness of 0.7-0.8 micrometer were somewhat more resistant to fretting than were smoother surfaces.

  7. Pulse-shaping based two-photon FRET stoichiometry.

    Science.gov (United States)

    Flynn, Daniel C; Bhagwat, Amar R; Brenner, Meredith H; Núñez, Marcos F; Mork, Briana E; Cai, Dawen; Swanson, Joel A; Ogilvie, Jennifer P

    2015-02-09

    Förster Resonance Energy Transfer (FRET) based measurements that calculate the stoichiometry of intermolecular interactions in living cells have recently been demonstrated, where the technique utilizes selective one-photon excitation of donor and acceptor fluorophores to isolate the pure FRET signal. Here, we present work towards extending this FRET stoichiometry method to employ two-photon excitation using a pulse-shaping methodology. In pulse-shaping, frequency-dependent phases are applied to a broadband femtosecond laser pulse to tailor the two-photon excitation conditions to preferentially excite donor and acceptor fluorophores. We have also generalized the existing stoichiometry theory to account for additional cross-talk terms that are non-vanishing under two-photon excitation conditions. Using the generalized theory we demonstrate two-photon FRET stoichiometry in live COS-7 cells expressing fluorescent proteins mAmetrine as the donor and tdTomato as the acceptor.

  8. Fluorescent Proteins as Genetically Encoded FRET Biosensors in Life Sciences

    Science.gov (United States)

    Hochreiter, Bernhard; Pardo Garcia, Alan; Schmid, Johannes A.

    2015-01-01

    Fluorescence- or Förster resonance energy transfer (FRET) is a measurable physical energy transfer phenomenon between appropriate chromophores, when they are in sufficient proximity, usually within 10 nm. This feature has made them incredibly useful tools for many biomedical studies on molecular interactions. Furthermore, this principle is increasingly exploited for the design of biosensors, where two chromophores are linked with a sensory domain controlling their distance and thus the degree of FRET. The versatility of these FRET-biosensors made it possible to assess a vast amount of biological variables in a fast and standardized manner, allowing not only high-throughput studies but also sub-cellular measurements of biological processes. In this review, we aim at giving an overview over the recent advances in genetically encoded, fluorescent-protein based FRET-biosensors, as these represent the largest and most vividly growing group of FRET-based sensors. For easy understanding, we are grouping them into four categories, depending on their molecular mechanism. These are based on: (a) cleavage; (b) conformational-change; (c) mechanical force and (d) changes in the micro-environment. We also address the many issues and considerations that come with the development of FRET-based biosensors, as well as the possibilities that are available to measure them. PMID:26501285

  9. a Study on the Fretting Fatigue Life of Zircaloy Alloys

    Science.gov (United States)

    Kwon, Jae-Do; Park, Dae-Kyu; Woo, Seung-Wan; Chai, Young-Suck

    Studies on the strength and fatigue life of machines and structures have been conducted in accordance with the development of modern industries. In particular, fine and repetitive cyclic damage occurring in contact regions has been known to have an impact on fretting fatigue fractures. The main component of zircaloy alloy is Zr, and it possesses good mechanical characteristics at high temperatures. This alloy is used in the fuel rod material of nuclear power plants because of its excellent resistance. In this paper, the effect of the fretting damage on the fatigue behavior of the zircaloy alloy is studied. Further, various types of mechanical tests such as tension and plain fatigue tests are performed. Fretting fatigue tests are performed with a flat-flat contact configuration using a bridge-type contact pad and plate-type specimen. Through these experiments, it is found that the fretting fatigue strength decreases by about 80% as compared to the plain fatigue strength. Oblique cracks are observed in the initial stage of the fretting fatigue, in which damaged areas are found. These results can be used as the basic data for the structural integrity evaluation of corrosion-resisting alloys considering the fretting damages.

  10. Fluorescent Proteins as Genetically Encoded FRET Biosensors in Life Sciences

    Directory of Open Access Journals (Sweden)

    Bernhard Hochreiter

    2015-10-01

    Full Text Available Fluorescence- or Förster resonance energy transfer (FRET is a measurable physical energy transfer phenomenon between appropriate chromophores, when they are in sufficient proximity, usually within 10 nm. This feature has made them incredibly useful tools for many biomedical studies on molecular interactions. Furthermore, this principle is increasingly exploited for the design of biosensors, where two chromophores are linked with a sensory domain controlling their distance and thus the degree of FRET. The versatility of these FRET-biosensors made it possible to assess a vast amount of biological variables in a fast and standardized manner, allowing not only high-throughput studies but also sub-cellular measurements of biological processes. In this review, we aim at giving an overview over the recent advances in genetically encoded, fluorescent-protein based FRET-biosensors, as these represent the largest and most vividly growing group of FRET-based sensors. For easy understanding, we are grouping them into four categories, depending on their molecular mechanism. These are based on: (a cleavage; (b conformational-change; (c mechanical force and (d changes in the micro-environment. We also address the many issues and considerations that come with the development of FRET-based biosensors, as well as the possibilities that are available to measure them.

  11. Fluorescent proteins as genetically encoded FRET biosensors in life sciences.

    Science.gov (United States)

    Hochreiter, Bernhard; Garcia, Alan Pardo; Schmid, Johannes A

    2015-10-16

    Fluorescence- or Förster resonance energy transfer (FRET) is a measurable physical energy transfer phenomenon between appropriate chromophores, when they are in sufficient proximity, usually within 10 nm. This feature has made them incredibly useful tools for many biomedical studies on molecular interactions. Furthermore, this principle is increasingly exploited for the design of biosensors, where two chromophores are linked with a sensory domain controlling their distance and thus the degree of FRET. The versatility of these FRET-biosensors made it possible to assess a vast amount of biological variables in a fast and standardized manner, allowing not only high-throughput studies but also sub-cellular measurements of biological processes. In this review, we aim at giving an overview over the recent advances in genetically encoded, fluorescent-protein based FRET-biosensors, as these represent the largest and most vividly growing group of FRET-based sensors. For easy understanding, we are grouping them into four categories, depending on their molecular mechanism. These are based on: (a) cleavage; (b) conformational-change; (c) mechanical force and (d) changes in the micro-environment. We also address the many issues and considerations that come with the development of FRET-based biosensors, as well as the possibilities that are available to measure them.

  12. Indicators based on fluorescence resonance energy transfer (FRET).

    Science.gov (United States)

    Tsien, Roger Y

    2009-07-01

    One of the major new trends in the design of indicators for optically imaging biochemical and physiological functions of living cells has been the exploitation of fluorescence resonance energy transfer (FRET). FRET is a well-known spectroscopic technique for monitoring changes in the proximity and mutual orientation of pairs of chromophores. It has long been used in biochemistry and cell biology to assess distances and orientations between specific labeling sites within a single macromolecule or between two separate molecules. More recently, macromolecules or molecular pairs have been engineered to change their FRET in response to biochemical and physiological signals such as membrane potential, cyclic AMP (cAMP), protease activity, free Ca(2+) and Ca(2+)-calmodulin (CaM) concentrations, protein-protein heterodimerization, phosphorylation, and reporter-gene expression. Because FRET is general, nondestructive, and easily imaged, it has proven to be one of the most versatile spectroscopic readouts available to the designer of new probes. FRET is particularly amenable to emission ratioing, which is more reliably quantifiable than single-wavelength monitoring and better suited than excitation ratioing to high-speed and laser-excited imaging. This article summarizes the photophysical principles of FRET and the types of indicators used.

  13. FRET-based identification of mRNAs undergoing translation.

    Directory of Open Access Journals (Sweden)

    Benjamin Stevens

    Full Text Available We present proof-of-concept in vitro results demonstrating the feasibility of using single molecule fluorescence resonance energy transfer (smFRET measurements to distinguish, in real time, between individual ribosomes programmed with several different, short mRNAs. For these measurements we use either the FRET signal generated between two tRNAs labeled with different fluorophores bound simultaneously in adjacent sites to the ribosome (tRNA-tRNA FRET or the FRET signal generated between a labeled tRNA bound to the ribosome and a fluorescent derivative of ribosomal protein L1 (L1-tRNA FRET. With either technique, criteria were developed to identify the mRNAs, taking into account the relative activity of the mRNAs. These criteria enabled identification of the mRNA being translated by a given ribosome to within 95% confidence intervals based on the number of identified FRET traces. To upgrade the approach for natural mRNAs or more complex mixtures, the stoichiometry of labeling should be enhanced and photobleaching reduced. The potential for porting these methods into living cells is discussed.

  14. FRET-based identification of mRNAs undergoing translation.

    Science.gov (United States)

    Stevens, Benjamin; Chen, Chunlai; Farrell, Ian; Zhang, Haibo; Kaur, Jaskiran; Broitman, Steven L; Smilansky, Zeev; Cooperman, Barry S; Goldman, Yale E

    2012-01-01

    We present proof-of-concept in vitro results demonstrating the feasibility of using single molecule fluorescence resonance energy transfer (smFRET) measurements to distinguish, in real time, between individual ribosomes programmed with several different, short mRNAs. For these measurements we use either the FRET signal generated between two tRNAs labeled with different fluorophores bound simultaneously in adjacent sites to the ribosome (tRNA-tRNA FRET) or the FRET signal generated between a labeled tRNA bound to the ribosome and a fluorescent derivative of ribosomal protein L1 (L1-tRNA FRET). With either technique, criteria were developed to identify the mRNAs, taking into account the relative activity of the mRNAs. These criteria enabled identification of the mRNA being translated by a given ribosome to within 95% confidence intervals based on the number of identified FRET traces. To upgrade the approach for natural mRNAs or more complex mixtures, the stoichiometry of labeling should be enhanced and photobleaching reduced. The potential for porting these methods into living cells is discussed.

  15. Fluorescent Protein Based FRET Pairs with Improved Dynamic Range for Fluorescence Lifetime Measurements.

    Directory of Open Access Journals (Sweden)

    Bobin George Abraham

    Full Text Available Fluorescence Resonance Energy Transfer (FRET using fluorescent protein variants is widely used to study biochemical processes in living cells. FRET detection by fluorescence lifetime measurements is the most direct and robust method to measure FRET. The traditional cyan-yellow fluorescent protein based FRET pairs are getting replaced by green-red fluorescent protein variants. The green-red pair enables excitation at a longer wavelength which reduces cellular autofluorescence and phototoxicity while monitoring FRET. Despite the advances in FRET based sensors, the low FRET efficiency and dynamic range still complicates their use in cell biology and high throughput screening. In this paper, we utilized the higher lifetime of NowGFP and screened red fluorescent protein variants to develop FRET pairs with high dynamic range and FRET efficiency. The FRET variations were analyzed by proteolytic activity and detected by steady-state and time-resolved measurements. Based on the results, NowGFP-tdTomato and NowGFP-mRuby2 have shown high potentials as FRET pairs with large fluorescence lifetime dynamic range. The in vitro measurements revealed that the NowGFP-tdTomato has the highest Förster radius for any fluorescent protein based FRET pairs yet used in biological studies. The developed FRET pairs will be useful for designing FRET based sensors and studies employing Fluorescence Lifetime Imaging Microscopy (FLIM.

  16. Microstructure, Impact Fatigue Resistance and Impact Wear Resistance of Wear Resistant Low Cr-Si Cast Iron

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    A great amount of iron and steel has been consumed in impact wear resistance parts such as grinding balls and lining plates in tube mills. Under this working conditions, the failure of wear resistant white irons is generally caused by fatigue spalling. The martensitic high chromium cast iron (WCr=15 %) has good wear resistance, but its cost is higher. The impact wear resistance of low chromium cast iron sometimes is not good. In the present paper ,a new wear resistant material-low Cr-Si cast iron was introduced. The influence of microstructure of cast iron on impact fatigue resistance and impact wear resistance was discussed. The ball-on-ball impact fatigue test, the high stress impact wear test and the field test of the grinding balls have been carried out. The results showed that the impact fatigue resistance (IFR) and impact wear resistance (IWR) of low Cr-Si cast iron are superior to typical low chromium cast irons and close to the martensitic high chromium cast iron. The main reasons are: ① The as-cast matrix of the low Cr-Si cast iron with stress released is pearlite with better plasticity and toughness; ② The high Si content improves the morphology of eutectic carbide, and has no secondary carbide resulting in less crack sources. All these factors are beneficial to the improvement of impact fatigue spalling resistance and impact wear resistance.

  17. Wear debris in cemented total hip arthroplasty.

    Science.gov (United States)

    Huo, M H; Salvati, E A; Buly, R L

    1991-03-01

    One of the most prevalent clinical problems in long-term follow up of total hip arthroplasty patients is loosening of prosthetic fixation. Factors contributing to mechanical failure of total hip reconstruction are complex and multiple. It has become increasingly apparent that wear debris from the prosthetic components may contribute significantly to this process. The authors summarize some of the current concepts concerning the detrimental effects of metallic debris in total hip arthroplasty.

  18. Wear of nanofilled dental composites in a newly-developed in vitro testing device

    Science.gov (United States)

    Lawson, Nathaniel C.

    Purpose. In vivo wear of dental composites can lead to loss of individual tooth function and the need to replace a composite restoration. To evaluate the wear performance of new and existing dental composites, we developed a novel system for measuring in vitro wear and we used this system to analyze the mechanisms of wear of nanofilled composite materials. Methods. A modified wear testing device was designed based on the Alabama wear testing machine. The new device consists of: (1) an antagonist which is lowered to and raised from the composite specimen by weight loading, (2) a motorized stage to cause the antagonist to slide 2mm on the composite surface, and (3) pumps for applying lubricant to the specimens. Various testing parameters of the device were examined before testing, including the impulse force, the third-body medium, the lubricant and antagonist. The parameters chosen for this study were 20N at 1Hz with a 33% glycerine lubricant and stainless steel antagonist. Three nano-composites were fabricated with a BisGMA polymer matrix and 40nm SiO2 filler particles at three filler loads (25%, 50% and 65%). The mechanical properties of the composites were measured. The materials were then tested in the modified wear testing device under impact wear, sliding wear and a combination of impact and sliding wear. The worn surfaces were then analyzed with a non-contact profilometer and SEM. Results. The volumetric wear data indicated that increasing filler content beyond 25% decreased the wear resistance of the composites. Increasing filler content increased hardness and decreased toughness. SEM evaluation of the worn specimens indicated that the 25% filled materials failed by fatigue and the 50% and 65% filled materials failed by abrasive wear. Impact wear produced fretting in this device and sliding wear is more aggressive than impact wear. Conclusion. Based on the results of this study and previous studies on this topic, manufacturers are recommended to use a filler

  19. Coupling behavior between adhesive and abrasive wear mechanism of aero-hydraulic spool valves

    Institute of Scientific and Technical Information of China (English)

    Chen Yunxia; Gong Wenjun; Kang Rui

    2016-01-01

    Leakage due to wear is one of the main failure modes of aero-hydraulic spool valves. This paper established a practical coupling wear model for aero-hydraulic spool valves based on dynamic system modelling theory. Firstly, the experiment for wear mechanism verification proved that adhesive wear and abrasive wear did coexist during the working process of spool valves. Sec-ondly coupling behavior of each wear mechanism was characterized by analyzing actual time-variation of model parameters during wear evolution process. Meanwhile, Archard model and three-body abrasive wear model were utilized for adhesive wear and abrasive wear, respectively. Furthermore, their coupling wear model was established by calculating the actual wear volume. Finally, from the result of formal test, all the required parameters for our model were obtained. The relative error between model prediction and data of pre-test was also presented to verify the accuracy of model, which demonstrated that our model was useful for providing accurate prediction of spool valve’s wear life.

  20. Nanoscale wear as a stress-assisted chemical reaction.

    Science.gov (United States)

    Jacobs, Tevis D B; Carpick, Robert W

    2013-02-01

    Wear of sliding contacts leads to energy dissipation and device failure, resulting in massive economic and environmental costs. Typically, wear phenomena are described empirically, because physical and chemical interactions at sliding interfaces are not fully understood at any length scale. Fundamental insights from individual nanoscale contacts are crucial for understanding wear at larger length scales, and to enable reliable nanoscale devices, manufacturing and microscopy. Observable nanoscale wear mechanisms include fracture and plastic deformation, but recent experiments and models propose another mechanism: wear via atom-by-atom removal ('atomic attrition'), which can be modelled using stress-assisted chemical reaction kinetics. Experimental evidence for this has so far been inferential. Here, we quantitatively measure the wear of silicon--a material relevant to small-scale devices--using in situ transmission electron microscopy. We resolve worn volumes as small as 25 ± 5 nm(3), a factor of 10(3) lower than is achievable using alternative techniques. Wear of silicon against diamond is consistent with atomic attrition, and inconsistent with fracture or plastic deformation, as shown using direct imaging. The rate of atom removal depends exponentially on stress in the contact, as predicted by chemical rate kinetics. Measured activation parameters are consistent with an atom-by-atom process. These results, by direct observation, establish atomic attrition as the primary wear mechanism of silicon in vacuum at low loads.

  1. Optical wear monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kidane, Getnet S; Desilva, Upul P.; He, Chengli; Ulerich, Nancy H.

    2016-07-26

    A gas turbine includes first and second parts having outer surfaces located adjacent to each other to create an interface where wear occurs. A wear probe is provided for monitoring wear of the outer surface of the first part, and includes an optical guide having first and second ends, wherein the first end is configured to be located flush with the outer surface of the first part. A fiber bundle includes first and second ends, the first end being located proximate to the second end of the optical guide. The fiber bundle includes a transmit fiber bundle comprising a first plurality of optical fibers coupled to a light source, and a receive fiber bundle coupled to a light detector and configured to detect reflected light. A processor is configured to determine a length of the optical guide based on the detected reflected light.

  2. Wear mechanism of heavy load friction contact pairs in tracked vehicle by combined ferrography and surface analysis

    Institute of Scientific and Technical Information of China (English)

    LI Li; ZHU You-li; HUANG Yuan-lin; XU Bin-shi; LI Xiao-yan

    2004-01-01

    Ferrography is deemed as one of the most effective methods for wear particle analysis and failure diagnosis. By analyzing the configuration, content and composition of wear particles in the lubricanting grease and the surface state of the worn surface with combined ferrography and surface analysis techniques, the wear mechanism of the ball groove of the master clutch's release device of a heavy load tracked vehicle was determined. Results show that the controlling wear mechanism is combined of abrasion, adhesion, contact fatigue and corrosion wear, which demonstrates the effectiveness of using combined ferrography and worn surface analysis for the study of wear mechanism of contact surface with friction.

  3. Wave propagation in coated cylinders with reference to fretting fatigue

    Indian Academy of Sciences (India)

    M Ramesh; Satish V Kailas; K R Y Simha

    2008-06-01

    Fretting fatigue is the phenomenon of crack initiation due to dynamic contact loading, a situation which is commonly encountered in mechanical couplings subjected to vibration. The study of fretting fatigue in high frequency regime has gained importance in recent years. However the stress wave effects at high frequency y loading is scanty in the literature. The objective of present investigation is to study stress wave propagation in cylinders with reference to high frequency fretting. The case of a coated cylinder is considered since coating is often provided to improve tribological properties of the component. Rule of mixtures is proposed to understand the dispersion phenomenon in coated or layered cylinder knowing the dispersion relation for the cases of homogeneous cylinders made of coating and substrate materials separately. The possibility of stress wave propagation at the interface with a particular phase velocity without dispersion is also discussed. Results are given for two different thicknesses of coating.

  4. Borromean three-body FRET in frozen Rydberg gases

    Science.gov (United States)

    Faoro, R.; Pelle, B.; Zuliani, A.; Cheinet, P.; Arimondo, E.; Pillet, P.

    2015-09-01

    Controlling the interactions between ultracold atoms is crucial for quantum simulation and computation purposes. Highly excited Rydberg atoms are considered in this prospect for their strong and controllable interactions known in the dipole-dipole case to induce non-radiative energy transfers between atom pairs, similarly to fluorescence resonance energy transfer (FRET) in biological systems. Here we predict few-body FRET processes in Rydberg atoms and observe the first three-body resonance energy transfer in cold Rydberg atoms using cold caesium atoms. In these resonances, additional relay atoms carry away an energy excess preventing the two-body resonance, leading thus to a Borromean type of energy transfer. These few-body processes present strong similarities with multistep FRET between chromophores sometimes called donor-bridge-acceptor or superexchange. Most importantly, they generalize to any Rydberg atom and could lead to new implementations of few-body quantum gates or entanglement.

  5. A portable FRET analyzer for rapid detection of sugar content.

    Science.gov (United States)

    Kim, Haseong; Kim, Hyo Sang; Ha, Jae-Seok; Lee, Seung-Goo

    2015-05-21

    Fluorescence resonance energy transfer (FRET) is widely used as a core process in biometric sensors to detect small molecules such as sugars, calcium ions, or amino acids. However, FRET based biosensors with innate weak signal intensity require the use of expensive, high-sensitive equipment. In the present study, these shortcomings were overcome with the fabrication of a sensitive, inexpensive, and portable analyzer which provides quantitative detection of small molecules in a liquid sample. The usability of the developed analyzer was successfully tested by measuring sucrose and maltose contents in commercially available beverage samples, with better performance than the conventional monochromator-type spectrofluorometer. It is anticipated that miniaturization of the equipment and improving the FRET based biosensors will contribute to the practical use of this hand-held analyzer in conditions where high-end equipment is not available.

  6. PixFRET, an ImageJ plug-in for FRET calculation that can accommodate variations in spectral bleed-throughs.

    Science.gov (United States)

    Feige, Jérôme N; Sage, Daniel; Wahli, Walter; Desvergne, Béatrice; Gelman, Laurent

    2005-09-01

    Fluorescence resonance energy transfer (FRET) allows the user to investigate interactions between fluorescent partners. One crucial issue when calculating sensitized emission FRET is the correction for spectral bleed-throughs (SBTs), which requires to calculate the ratios between the intensities in the FRET and in the donor or acceptor settings, when only the donor or acceptor are present. Theoretically, SBT ratios should be constant. However, experimentally, these ratios can vary as a function of fluorophore intensity, and assuming constant values may hinder precise FRET calculation. One possible cause for such a variation is the use of a microscope set-up with different photomultipliers for the donor and FRET channels, a set-up allowing higher speed acquisitions on very dynamic fluorescent molecules in living cells. Herein, we show that the bias introduced by the differential response of the two PMTs can be circumvented by a simple modeling of the SBT ratios as a function of fluorophore intensity. Another important issue when performing FRET is the localization of FRET within the cell or a population of cells. We hence developed a freely available ImageJ plug-in, called PixFRET, that allows a simple and rapid determination of SBT parameters and the display of normalized FRET images. The usefulness of this modeling and of the plug-in are exemplified by the study of FRET in a system where two interacting nuclear receptors labeled with ECFP and EYFP are coexpressed in living cells.

  7. Simultaneous quantitative live cell imaging of multiple FRET-based biosensors.

    Directory of Open Access Journals (Sweden)

    Andrew Woehler

    Full Text Available We have developed a novel method for multi-color spectral FRET analysis which is used to study a system of three independent FRET-based molecular sensors composed of the combinations of only three fluorescent proteins. This method is made possible by a novel routine for computing the 3-D excitation/emission spectral fingerprint of FRET from reference measurements of the donor and acceptor alone. By unmixing the 3D spectrum of the FRET sample, the total relative concentrations of the fluorophores and their scaled FRET efficiencies are directly measured, from which apparent FRET efficiencies can be computed. If the FRET sample is composed of intramolecular FRET sensors it is possible to determine the total relative concentration of the sensors and then estimate absolute FRET efficiency of each sensor. Using multiple tandem constructs with fixed FRET efficiency as well as FRET-based calcium sensors with novel fluorescent protein combinations we demonstrate that the computed FRET efficiencies are accurate and changes in these quantities occur without crosstalk. We provide an example of this method's potential by demonstrating simultaneous imaging of spatially colocalized changes in [Ca(2+], [cAMP], and PKA activity.

  8. Investigation on Friction and Wear of Cold Rolled High Strength Steel against an AISI52100 Counterpart

    Directory of Open Access Journals (Sweden)

    Jiwon Hur

    2017-03-01

    Full Text Available This article investigates the friction and wear of cold rolled high strength steel at various displacement amplitudes. Reciprocal sliding tests are carried out using a ball-on-flat testing apparatus. The tangential force occurring at the contact surface between a high strength steel specimen and an AISI52100 ball is measured during the tests. After each test, the worn surface profile on the steel specimen is determined. Experimental results show that the ratio of the maximum tangential to the normal force remains at 0.7 after an initial rapid increase, and the ratio does not greatly change according to the imposed displacement amplitudes (in the range of 0.05 mm and 0.3 mm. The wear volume loss on the steel specimen increases according to the number of cycles. It is determined that the wear rate of the specimen changes with respect to the imposed displacement amplitude. That is, the wear rate rapidly increases within the displacement amplitude range of 0.05 mm to 0.09 mm, while the wear rate gradually increases when the displacement amplitude is greater than 0.2 mm. The obtained results provide the friction and wear behaviors of cold rolled high strength steel in fretting and reciprocal sliding regimes.

  9. Intravital FRET: Probing Cellular and Tissue Function in Vivo

    Directory of Open Access Journals (Sweden)

    Helena Radbruch

    2015-05-01

    Full Text Available The development of intravital Förster Resonance Energy Transfer (FRET is required to probe cellular and tissue function in the natural context: the living organism. Only in this way can biomedicine truly comprehend pathogenesis and develop effective therapeutic strategies. Here we demonstrate and discuss the advantages and pitfalls of two strategies to quantify FRET in vivo—ratiometrically and time-resolved by fluorescence lifetime imaging—and show their concrete application in the context of neuroinflammation in adult mice.

  10. Rupture pressure of wear degraded alloy 600 steam generator tubings

    Science.gov (United States)

    Hwang, Seong Sik; Namgung, Chan; Jung, Man Kyo; Kim, Hong Pyo; Kim, Joung Soo

    2008-02-01

    Fretting/wear degradation at the tube support in the U-bend region of a steam generator (SG) of a pressurized water reactor (PWR) has been reported. Simulated fretted flaws were machined on SG tubes of 195 mm in length. A pressure test was carried out with the tubes at room temperature by using a high pressure test facility which consisted of a water pressurizing pump, a test specimen section and a control unit. Water leak rates just after a ligament rupture or a burst were measured. Tubes degraded by up to 70% of the tube wall thickness (TW) showed a high safety margin in terms of the burst pressure during normal operating conditions. Tubes degraded by up to 50% of the TW did not show burst. Burst pressure depended on the defect depths rather than on the wrap angles. The tube with a wrap angle of 0° showed a fish mouth fracture, whereas the tube with a 45° wrap angle showed a three way fracture.

  11. Effect of equal channel angular extrusion on wear and corrosion behavior of the orthopedic Ti-13Nb-13Zr alloy in simulated body fluid

    Energy Technology Data Exchange (ETDEWEB)

    Suresh, K.S. [Department of Materials. Engineering, Indian Institute of Science, Bangalore 560012 (India); Geetha, M., E-mail: geethamanivasagam@vit.ac.in [School of Mechanical and Building Sciences, VIT University, Vellore (India); Richard, C. [Laboratoire de Mecanique et de Rheologie EA 2640, Polytech' Tours, 37000 Tours (France); Landoulsi, J. [Laboratoire de Reactivite de Surface, UMR 7197 CNRS, Universite Pierre and Marie Curie - Paris VI, 4 Place Jussieu, Case 178, F-75252 Paris (France); Ramasawmy, H. [University of Mauritius, Faculty of Engineering, Reduit (Mauritius); Suwas, S. [Department of Materials. Engineering, Indian Institute of Science, Bangalore 560012 (India); Asokamani, R. [School of Mechanical and Building Sciences, VIT University, Vellore (India)

    2012-05-01

    We report investigations on the texture, corrosion and wear behavior of ultra-fine grained (UFG) Ti-13Nb-Zr alloy, processed by equal channel angular extrusion (ECAE) technique, for biomedical applications. The microstructure obtained was characterized by X-ray line profile analysis, scanning electron microscope (SEM) and electron back scattered diffraction (EBSD). We focus on the corrosion resistance and the fretting behavior, the main considerations for such biomaterials, in simulated body fluid. To this end, potentiodynamic polarization tests were carried out to evaluate the corrosion behavior of the UFG alloy in Hanks solution at 37 Degree-Sign C. The fretting wear behavior was carried out against bearing steel in the same conditions. The roughness of the samples was also measured to examine the effect of topography on the wear behavior of the samples. Our results showed that the ECAE process increases noticeably the performance of the alloy as orthopedic implant. Although no significant difference was observed in the fretting wear behavior, the corrosion resistance of the UFG alloy was found to be higher than the non-treated material. Highlights: Black-Right-Pointing-Pointer Relevancy of ECAE process applied to titanium alloy for biomedical applications. Black-Right-Pointing-Pointer Significant improvement of mechanical properties of the surface. Black-Right-Pointing-Pointer Noticeable increase of the corrosion resistance in simulated body fluid.

  12. Effect of Contact Load on the Fretting Fatigue of Steel Wire under Alkaline Corrosive Environment%碱性腐蚀环境下接触载荷对钢丝微动疲劳行为的影响

    Institute of Scientific and Technical Information of China (English)

    赵维建; 张德坤; 张泽锋; 王崧全; 王世博

    2012-01-01

    The fretting fatigue tests of the mine steel wires under alkaline corrosive environment are performded on a self - made fretting fatigue test machine. The fretting fatigue behaviors of steel wires with a strain ration of 0.8 are studied under different contact loads. The damage mechanisms of steel wires are analyzed by the optical microscopy and scanning electron microscopy. The results indicate that the evolution of friction coefficients of steel wires can be divided into four stages, i.e. , running- in period, ascending period, declining period and stable period. The fretting regime of steel wires is gross slip regime under the four different contact loads. Corrosive wear, abrasive wear, fatigue wear and plastic deformation are the main wear mechanisms. The fatigue lifetime of the fretted steel wires is inversely proportional to the wear depth. Fatigue fracture surface can be divided into three regions, i.e. ,fatigue source region, crack propagation region and transient break regions.%以矿用钢丝为研究对象,在自制的钢丝微动疲劳试验机上开展钢丝在碱性腐蚀环境下的微动疲劳试验,考察钢丝在应变比为0.8时不同接触载荷下钢丝的微动运行特性,并用光学显微镜和扫描电子显微镜观察钢丝的磨痕和断口形貌,分析其微动磨损和疲劳断裂机理.结果表明:不同接触载荷下钢丝的摩擦系数具有相同的变化趋势,均可以分为4个阶段:跑合期、上升期、下降期和稳定期;4种不同接触载荷下钢丝摩擦副均运行于滑移状态,磨损机制以腐蚀磨损、磨粒磨损、疲劳磨损和塑性变形为主;钢丝疲劳寿命与磨损量成反比,疲劳断口可分为3个区:疲劳源区、扩展区和瞬断区.

  13. Unexpected wear of an unicompartimental knee arthroplasty in oxidized zirconium.

    Science.gov (United States)

    Luyet, Anais; Fischer, Jean-François; Jolles, Brigitte M; Lunebourg, Alexandre

    2015-12-01

    Unicompartimental knee arthroplasty is a successful procedure for the treatment of localized osteoarthritis to one compartment of the knee with good long-term results. However, several modes of failure of unicompartimental knee arthroplasty have been described, namely aseptic or septic loosening, progression of disease, wear, and instability. Metallosis after unicompartimental knee arthroplasty is rarely reported and is most often related with polyethylene wear or break. We report on a case of rapid failure of unicompartimental knee arthroplasty in oxidized zirconium associated with metallosis secondary to the dislocation of the polyethylene.

  14. Effects of gap size and excitation frequency on the vibrational behavior and wear rate of fuel rods

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Zupan [Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Thouless, M.D., E-mail: thouless@umich.edu [Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Department of Materials Science & Engineering, University of Michigan, Ann Arbor, MI 48109 (United States); Lu, Wei, E-mail: weilu@umich.edu [Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109 (United States)

    2016-11-15

    Graphical abstract: A wear map shows wear rate as a function of the grid-to-rod gap size and the frequency of the excitation force. The critical gap size, which is associated with the maximum wear rate, lies within the harmonic regime. In the no wear region the amplitude of the rod vibration is smaller than the gap size so that no impact between the rod and plate can happen. The curve of the resonant frequency of the system appears to overlap with the peaks in the contour. - Highlights: • A 3D finite-element based approach to study grid-to-rod fretting. • Two important factors: grid-to-rod gap size and frequency of the excitation force. • Rod vibration shows three regimes: harmonic, period-doubling and chaotic. • A critical gap size is associated with the maximum wear rate. • A wear map shows wear rate as a function of the gap size and excitation frequency. - Abstract: Grid-to-rod fretting (GTRF) wear is a major cause of fuel leaks. Understanding its mechanism is crucial for improving the reliability of nuclear reactors. In this paper we present a three-dimensional, finite-element based approach, which reveals how the wear rate depends on the size of the gap between the grid and the fuel rod, and on the frequency of the excitation force. We show that these two factors affect the dynamic vibration of the rod, which leads to three different regimes: harmonic, period-doubling and chaotic. The wear rate in the harmonic regime is significantly larger than that in the other two regimes, and reaches a maximum when the excitation frequency is close to the resonant frequency of the system, which is dependent on the gap size. We introduce the concept of a critical gap size that gives the maximum wear rate, and we identify the properties and values of this critical gap size. A wear map is developed as a result of a large number of parametric studies. This map shows quantitatively the wear rate as a function of the gap size and excitation frequency, and will be a

  15. Wear resistant zirconium base alloy article for water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Gillett, J.E.; Shockling, L.A.; Sherwood, D.G.

    1988-03-01

    In a water reactor operating environment, the combination having improved fretting wear resistance is described comprising: an elongated tubular water displacer rod; having a low neutron absorption cross section guide support plates distributed along the length of the water displacer rod; the water displacer rod intersecting the guide support plates through apertures in the guide support plates; the water displacer rod having a plurality of spaced apart annular electrospark deposited coatings, each coating facing the wall of a respective aperture, the electrospark deposited coatings comprising Cr/sub 2/C/sub 3/; wherein the water displacer rod has a tube wall composed of a zirconium base alloy; and wherein the guide support plates are composed of a stainless steel alloy.

  16. Comparative wear mapping techniques

    DEFF Research Database (Denmark)

    Alcock, J.; Sørensen, Ole Toft; Jensen, S.

    1996-01-01

    Pin surfaces were analysed by laser profilometry. Two roughness parameters, R(a) and the fractal dimension, were investigated as a first step towards methods of quantitative wear mechanism mapping. Both parameters were analysed for their relationship to the severity and prevalence of a mechanism....

  17. The study of property and damage mechanism about fretting corrosion of aluminum alloy%LY12铝合金微动腐蚀特性及损伤机制研究

    Institute of Scientific and Technical Information of China (English)

    徐丽; 陈跃良; 于向财; 胡建军

    2011-01-01

    微动广泛存在于航空航天等各种机械构件中,加速构件接触表面及表层裂纹的萌生与扩展.由于海军飞机服役环境的复杂性,铝合金构件腐蚀相当严重,因此了解铝合金微动腐蚀规律具有极其重要的作用,有助于减少微动腐蚀,为老龄飞机的维护提供更多技术指导.结合微动损伤理论分析了铝合金在大气和盐水中的微动特性,总结了微动磨损过程主要的损伤机制.%Fretting usually occurs in the mechanical components of aeronautics and astronautics, and also accelerates expansion of cracks about the surface of structures. Because of the complexity of the surrounding of aircrafts, the corrosion of aluminum alloy structures is great serious. Therefore, it is very important to understand the discipline of fretting corrosion about aluminum alloy, which may help to reduce fretting corrosion and offer more technology in helping of maintenance about older airplane. In this paper, we analyze the property of fretting corrosion about aluminum alloy in atmosphere or in saline condition with fretting damage theory, and summarize the main damage mechanism of fretting wear.

  18. Assessment of wear facets produced by the ACTA wear machine

    DEFF Research Database (Denmark)

    Benetti, Ana R; Larsen, Liselotte; Dowling, Adam H

    2016-01-01

    OBJECTIVE: To investigate the use of a three-dimensional (3D) digital scanning method in determining the accuracy of the wear performance parameters of resin-based composites (RBCs) determined using a two-dimensional (2D) analogue methodology following in-vitro testing in an Academisch Centrum...... an assessment of the potential of the experimental RBC formulations for clinical usage. CONCLUSION: The 3D technique allowed for the assessment of mean maximum wear depth and mean total volumetric wear which enables tribological analyses of the wear facet and therefore the wear mechanisms operative. Employing...... profilers is useful when screening potential new RBC formulations for the restoration of posterior dentition....

  19. Alternating-laser excitation : single-molecule FRET and beyond

    NARCIS (Netherlands)

    Hohlbein, Johannes; Craggs, Timothy D.; Cordes, Thorben

    2014-01-01

    The alternating-laser excitation (ALEX) scheme continues to expand the possibilities of fluorescence-based assays to study biological entities and interactions. Especially the combination of ALEX and single-molecule Forster Resonance Energy Transfer (smFRET) has been very successful as ALEX enables

  20. Application of FRET probes in the analysis of neuronal plasticity

    Directory of Open Access Journals (Sweden)

    Yoshibumi eUeda

    2013-10-01

    Full Text Available Breakthroughs in imaging techniques and optical probes in recent years have revolutionized the field of life sciences in ways that traditional methods could never match. The spatial and temporal regulation of molecular events can now be studied with great precision. There have been several key discoveries that have made this possible. Since GFP was cloned in 1992, it has become the dominant tracer of proteins in living cells. Then the evolution of color variants of GFP opened the door to the application of Förster resonance energy transfer (FRET, which is now widely recognized as a powerful tool to study complicated signal transduction events and interactions between molecules. Employment of fluorescent lifetime imaging microscopy (FLIM allows the precise detection of FRET in small subcellular structures such as dendritic spines. In this review, we provide an overview of the basic and practical aspects of FRET imaging and discuss how different FRET probes have revealed insights into the molecular mechanisms of synaptic plasticity and enabled visualization of neuronal network activity both in vitro and in vivo.

  1. Plant-based FRET biosensor discriminates enviornmental zinc levels

    Science.gov (United States)

    Heavy metal accumulation in the environment poses great risks to flora and fauna. However, monitoring sites prone to accumulation poses scale and economic challenges. In this study, we present and test a method for monitoring these sites using fluorescent resonance energy transfer (FRET) change in r...

  2. Uncovering Aberrant Mutant PKA Function with Flow Cytometric FRET

    Directory of Open Access Journals (Sweden)

    Shin-Rong Lee

    2016-03-01

    Full Text Available Biology has been revolutionized by tools that allow the detection and characterization of protein-protein interactions (PPIs. Förster resonance energy transfer (FRET-based methods have become particularly attractive as they allow quantitative studies of PPIs within the convenient and relevant context of living cells. We describe here an approach that allows the rapid construction of live-cell FRET-based binding curves using a commercially available flow cytometer. We illustrate a simple method for absolutely calibrating the cytometer, validating our binding assay against the gold standard isothermal calorimetry (ITC, and using flow cytometric FRET to uncover the structural and functional effects of the Cushing-syndrome-causing mutation (L206R on PKA’s catalytic subunit. We discover that this mutation not only differentially affects PKAcat’s binding to its multiple partners but also impacts its rate of catalysis. These findings improve our mechanistic understanding of this disease-causing mutation, while illustrating the simplicity, general applicability, and power of flow cytometric FRET.

  3. Fretting Fatigue Behavior of Shot-Peened IN 100

    Science.gov (United States)

    2006-03-01

    117 - x - List of Figures Figure Page Figure 1. Blade/ Disc ...Blade/ Disc Dovetail Joint in a Turbine Engine. - 7 - Figure 2. Simplified Fretting Configuration Contact Load (P) Fatigue Specimen (P...steam turbine power plants, medical applications, nuclear power systems, and in the chemical petrochemical industries 28. Nickel superalloys are

  4. Wear Resistance and Wear Mechanism of a Hot Dip Aluminized Steel in Sliding Wear Test

    Science.gov (United States)

    Xue, Zhiyong; Hao, Xiaoyang; Huang, Yao; Gu, Lingyun; Ren, Yu; Zheng, Ruipeng

    2016-12-01

    Sliding wear experiments were conducted on a hot dip aluminized steel to investigate its wear resistance and wear mechanism. The wear tests were also carried out on a hot dip galvanized steel and the base material (steel Q345) as a comparison. Results show that the wear resistance and hardness of the hot dip aluminized steel are significantly higher than that of the hot dip galvanized steel and the steel Q345 at room temperature. The better wear resistance of the hot dip aluminized steel attributes mainly to the formation of a transition layer containing abundant Fe-Al intermetallic compounds and the transformation of wear-resisting oxides during the friction process. The main phase in the transition layer is Fe2Al5. The thickness of the transition layer is about 90-120 μm. When the wear load increases from 3 N to 19 N, the wear type of the aluminized layer transform from adhesive wear (3 N) into abrasive wear (7 N) and finally into slight wear mixed with oxidation (higher than 11 N).

  5. The Failure Mechanisms and Solutions of Anti-wear Thermal Spray Coatings for Solid Waste Incineration Circulating Fluidized Bed Boiler%垃圾焚烧循环流化床锅炉防磨热喷涂涂层失效机理及对策

    Institute of Scientific and Technical Information of China (English)

    胡金力; 陈国星; 黄科峰; 吴树辉; 盛洪产; 楼军; 章平衡; 薛猛

    2012-01-01

    本文分析了垃圾焚烧炉循环流化床(CFB)锅炉水冷壁管防磨热喷涂涂层的失效机理:S及碱金属等引起的S腐蚀导致涂层鼓泡,在炉内高温物料的磨损下涂层逐渐破损、剥落直至加速剥落失效。热喷涂防腐抗磨双效复合涂层能很好的解决了垃圾焚烧炉水冷壁同时存在的高温腐蚀和磨损的问题。%This paper analyzes the failure mechanisms of anti-wear thermal spray coatings on water wall tube of the wastes incineration Circulating Fluidized Bed (CFB) boiler. Sulfur corrosion caused by alkali, S and the Compound above lead to coatings bubbling, which are then gradually abraded by the high temperature flowing objects in the boiler. The coatings would be peeled off faster and faster once they are breaking. Composite thermal spray coatings of double-effect,corrosion, both abrasion resistant anticorrosive, is a good solution to high temperature corrosion and wear problems simultaneously.

  6. Color control through FRET efficiency modulation using CDI (Conference Presentation)

    Science.gov (United States)

    Wolowelsky, Karni; Guyes, Eric; Rubin, Shimon; Suss, Matthew; Bercovici, Moran; Rotschild, Carmel

    2017-02-01

    Although much progress was made in light emitting devices, the ability to electrically control their spectral emission remains limited. We will present a novel approach and experimental results for dynamic color control, by electrically modulating the non-radiative Forster resonance energy transfer (FRET) efficiency between donor and acceptor dyes in a solution. FRET efficiency depends on the 6th power of the distance between donor and acceptor dye molecules, and thus, it is sensitive to variations in acceptor's concentration. Controlled acceptor concentrations could be achieved by attracting or repelling ionic dyes from the electrodes using a capacitive deionization (CDI) cell, with high surface area porous electrodes. This approach to dynamic color control may open new directions in 100% fill-factor displays, and can be expanded to energy saving applications such as controlling building's external wall emissivity. We studied the modulation of a single dye emission using a CDI cell with negatively charged Fluorescein Sodium Salt in aquatic solution. Photoluminescence was measured along few charging-discharging CDI cycles and showed the ability to control extensive optical response through CDI. We experimented with two types of FRET-pair dyes: a) anion-cation, where the acceptor and the donor ions are oppositely charged, and b) zwitterion and ion, where the donor is neutral. We found that electrical control on FRET in aquatic solution is weak, due to hydrophobic attractive interaction between the acceptor and the donor. In order to avoid this effect, we are experimenting FRET control in organic solvents. These results will be presented in the talk.

  7. TIRE WEAR MODELING

    Directory of Open Access Journals (Sweden)

    Rosen IVANOV

    2016-09-01

    Full Text Available On the basis of a known relationship, an enhanced model for specific tire wear per kilometer has been developed. It is appropriate for practical use - for evaluation of the influence of different factors. Two types of experiments have been carried out with a testing device - one without sideslip, but with a known longitudinal slip, and the other one with the same longitudinal slip but also with a known sideslip. As a result, the coefficients of the proportion of the developed model have been evaluated. After the model validation, an analytical investigation concerning the influence of tire pressure, sideslip and longitudinal slip on the tire wear has been carried out. The results are presented graphically.

  8. Single-Molecule Pull-down FRET (SiMPull-FRET) to dissect the mechanisms of biomolecular machines

    Science.gov (United States)

    Kahlscheuer, Matthew L.; Widom, Julia; Walter, Nils G.

    2016-01-01

    Spliceosomes are multi-megadalton RNA-protein complexes responsible for the faithful removal of non-coding segments (introns) from pre-messenger RNAs (pre-mRNAs), a process critical for the maturation of eukaryotic mRNAs for subsequent translation by the ribosome. Both the spliceosome and ribosome, as well as many other RNA and DNA processing machineries, contain central RNA components that endow biomolecular complexes with precise, sequence-specific nucleic acid recognition and versatile structural dynamics. Single molecule fluorescence (or Förster) resonance energy transfer (smFRET) microscopy is a powerful tool for the study of local and global conformational changes of both simple and complex biomolecular systems involving RNA. The integration of biochemical tools such as immunoprecipitation with advanced methods in smFRET microscopy and data analysis has opened up entirely new avenues towards studying the mechanisms of biomolecular machines isolated directly from complex biological specimens such as cell extracts. Here we detail the general steps for using prism-based total internal reflection fluorescence (TIRF) microscopy in exemplary single molecule pull-down FRET (SiMPull-FRET) studies of the yeast spliceosome and discuss the broad application potential of this technique. PMID:26068753

  9. Engine oil wear resistance

    Directory of Open Access Journals (Sweden)

    A.N. Farhanah

    2015-03-01

    Full Text Available Lubricants play a vital role in an internal combustion engine to lubricate parts and help to protect and prolong the engine life. Lubricant also will help to reduce wear by creating lubricating film between the moving parts hence reduce metal-to-metal contacts. Engine oil from three different manufacturers with the same SAE viscosity grade available in market does not mean it will have the same lubricity for an engine. In this study, commercial mineral lubrication oil (SAE 10W-30 from three manufacturers was investigated to compare the lubrication performance at three different temperatures (40˚C, 70˚C and 100˚C in 60 minutes time duration by using four ball wear tester. The speed will be varied from 1000 rpm to 2500 rpm. Results show that all three lubricants have different lubricity performance; the smaller the wear scar, the better the lubricant since the lubricant can protect the moving surfaces from direct metal-to-metal contact occur.

  10. rFRET: A comprehensive, Matlab-based program for analyzing intensity-based ratiometric microscopic FRET experiments.

    Science.gov (United States)

    Nagy, Peter; Szabó, Ágnes; Váradi, Tímea; Kovács, Tamás; Batta, Gyula; Szöllősi, János

    2016-04-01

    Fluorescence or Förster resonance energy transfer (FRET) remains one of the most widely used methods for assessing protein clustering and conformation. Although it is a method with solid physical foundations, many applications of FRET fall short of providing quantitative results due to inappropriate calibration and controls. This shortcoming is especially valid for microscopy where currently available tools have limited or no capability at all to display parameter distributions or to perform gating. Since users of multiparameter flow cytometry usually apply these tools, the absence of these features in applications developed for microscopic FRET analysis is a significant limitation. Therefore, we developed a graphical user interface-controlled Matlab application for the evaluation of ratiometric, intensity-based microscopic FRET measurements. The program can calculate all the necessary overspill and spectroscopic correction factors and the FRET efficiency and it displays the results on histograms and dot plots. Gating on plots and mask images can be used to limit the calculation to certain parts of the image. It is an important feature of the program that the calculated parameters can be determined by regression methods, maximum likelihood estimation (MLE) and from summed intensities in addition to pixel-by-pixel evaluation. The confidence interval of calculated parameters can be estimated using parameter simulations if the approximate average number of detected photons is known. The program is not only user-friendly, but it provides rich output, it gives the user freedom to choose from different calculation modes and it gives insight into the reliability and distribution of the calculated parameters. © 2016 International Society for Advancement of Cytometry.

  11. Pure mechanical wear loss measurement in corrosive wear

    Indian Academy of Sciences (India)

    Yanliang Huang; Xiaoxia Jiang; Sizuo Li

    2000-12-01

    The method for the measurement of the pure mechanical wear loss for 321 stainless steel, 1045 steel and pure iron in the study of the synergy between corrosion and wear was studied. The methods studied included the measurement in distilled water, by cathodic protection and by adding inhibitor KI, and all were compared with the wear loss in air. The experiment showed that the pure mechanical wear losses and friction coefficients obtained by the three methods were close to each other and can be used to calculate the various wear components in the study of the interaction of corrosion and wear, but the measurements in distilled water for pure iron and 1045 steel are not recommended due to their corrosion.

  12. The wear of two orthopaedic biopolymers against each other.

    Science.gov (United States)

    Joyce, T J

    2005-01-01

    The potential for all-polymer prostheses has not been widely investigated. It might be expected that the wear of such biomaterial combinations would be excessive, but an in vivo study of all polymer knee prostheses reported that there were no failures due to wear, even after ten years of clinical use. This design of knee prosthesis used polyacetal and ultra high molecular weight polyethylene (UHMWPE) as the biopolymers. Similarly, an earlier in vitro study of polyacetal and UHMWPE hip prostheses indicated lower wear than for a cobalt chrome and UHMWPE combination. Therefore this study set out to test the poly-acetal and UHMWPE combination in a wear screening rig which had previously been validated against clinical data for artificial hip joints. Two different motion conditions were applied to the test samples and each biopolymer was tested as both pin and plate. Interestingly it was found that, whatever the contribution from pin or plate, the total mean wear factors were 1.5 10 -6 mm 3/Nm under reciprocation-only, and 4.1 10 -6 mm 3 /Nm under multi-directional motion. These wear factors were greater than those found when a conventional metal-on-UHMWPE couple was tested under the same loading, motion and lu-bricant conditions. A comparison was also undertaken with the wear of other orthopaedic biopolymer combinations, namely cross-linked polyethylene (XLPE) against itself, and UHMWPE against itself. The XLPE pairing showed somewhat lower wear than the polyacetal and UHMWPE couple, while the UHMWPE pairing showed the highest wear of all, approximately an or-der of magnitude greater than the polyacetal and UHMWPE combination.

  13. Combined Corrosion and Wear of Aluminium Alloy 7075-T6

    NARCIS (Netherlands)

    Liu, Y.; Mol, J.M.C.; Janssen, G.C.A.M.

    2016-01-01

    The aluminium alloy 7075-T6 is widely used in engineering. In some applications, like slurry transport, corrosion and abrasion occur simultaneously, resulting in early material failure. In the present work, we investigated the combined effect of corrosion and wear on the aluminium alloy 7075-T6. We

  14. Combined Corrosion and Wear of Aluminium Alloy 7075-T6

    NARCIS (Netherlands)

    Liu, Y.; Mol, J.M.C.; Janssen, G.C.A.M.

    2016-01-01

    The aluminium alloy 7075-T6 is widely used in engineering. In some applications, like slurry transport, corrosion and abrasion occur simultaneously, resulting in early material failure. In the present work, we investigated the combined effect of corrosion and wear on the aluminium alloy 7075-T6. We

  15. Time-gated FRET nanoassemblies for rapid and sensitive intra- and extracellular fluorescence imaging.

    Science.gov (United States)

    Afsari, Hamid Samareh; Cardoso Dos Santos, Marcelina; Lindén, Stina; Chen, Ting; Qiu, Xue; van Bergen En Henegouwen, Paul M P; Jennings, Travis L; Susumu, Kimihiro; Medintz, Igor L; Hildebrandt, Niko; Miller, Lawrence W

    2016-06-01

    Time-gated Förster resonance energy transfer (FRET) using the unique material combination of long-lifetime terbium complexes (Tb) and semiconductor quantum dots (QDs) provides many advantages for highly sensitive and multiplexed biosensing. Although time-gated detection can efficiently suppress sample autofluorescence and background fluorescence from directly excited FRET acceptors, Tb-to-QD FRET has rarely been exploited for biomolecular imaging. We demonstrate Tb-to-QD time-gated FRET nanoassemblies that can be applied for intra- and extracellular imaging. Immunostaining of different epitopes of the epidermal growth factor receptor (EGFR) with Tb- and QD-conjugated antibodies and nanobodies allowed for efficient Tb-to-QD FRET on A431 cell membranes. The broad usability of Tb-to-QD FRET was further demonstrated by intracellular Tb-to-QD FRET and Tb-to-QD-to-dye FRET using microinjection as well as cell-penetrating peptide-mediated endocytosis with HeLa cells. Effective brightness enhancement by FRET from several Tb to the same QD, the use of low nanomolar concentrations, and the quick and sensitive detection void of FRET acceptor background fluorescence are important advantages for advanced intra- and extracellular imaging of biomolecular interactions.

  16. Detecting stoichiometry of macromolecular complexes in live cells using FRET

    Science.gov (United States)

    Ben-Johny, Manu; Yue, Daniel N.; Yue, David T.

    2016-01-01

    The stoichiometry of macromolecular interactions is fundamental to cellular signalling yet challenging to detect from living cells. Fluorescence resonance energy transfer (FRET) is a powerful phenomenon for characterizing close-range interactions whereby a donor fluorophore transfers energy to a closely juxtaposed acceptor. Recognizing that FRET measured from the acceptor's perspective reports a related but distinct quantity versus the donor, we utilize the ratiometric comparison of the two to obtain the stoichiometry of a complex. Applying this principle to the long-standing controversy of calmodulin binding to ion channels, we find a surprising Ca2+-induced switch in calmodulin stoichiometry with Ca2+ channels—one calmodulin binds at basal cytosolic Ca2+ levels while two calmodulins interact following Ca2+ elevation. This feature is curiously absent for the related Na channels, also potently regulated by calmodulin. Overall, our assay adds to a burgeoning toolkit to pursue quantitative biochemistry of dynamic signalling complexes in living cells. PMID:27922011

  17. NIR FRET Fluorophores for Use as an Implantable Glucose Biosensor

    Directory of Open Access Journals (Sweden)

    Majed DWEIK

    2008-12-01

    Full Text Available Development of an in vivo optical sensor requires the utilization of Near Infra Red (NIR fluorophores due to their ability to operate within the biological tissue window. Alexa Fluor 750 (AF750 and Alexa Fluor 680 (AF680 were examined as potential NIR fluorophores for an in vivo fluorescence resonance energy transfer (FRET glucose biosensor. AF680 and AF750 found to be a FRET pair and percent energy transfer was calculated. Next, the tested dye pair was utilized in a competitive binding assay in order to detect glucose. Concanavalin A (Con A and dextran have binding affinity, but in the presence of glucose, glucose displaces dextran due to its higher affinity to Con A than dextran. Finally, the percent signal transfer through porcine skin was examined. The results showed with approximately 4.0 mm porcine skin thickness, 1.98 % of the fluorescence was transmitted and captured by the detector.

  18. Single cell FRET analysis for the identification of optimal FRET-pairs in Bacillus subtilis using a prototype MEM-FLIM system.

    Directory of Open Access Journals (Sweden)

    Ruud G J Detert Oude Weme

    Full Text Available Protein-protein interactions can be studied in vitro, e.g. with bacterial or yeast two-hybrid systems or surface plasmon resonance. In contrast to in vitro techniques, in vivo studies of protein-protein interactions allow examination of spatial and temporal behavior of such interactions in their native environment. One approach to study protein-protein interactions in vivo is via Förster Resonance Energy Transfer (FRET. Here, FRET efficiency of selected FRET-pairs was studied at the single cell level using sensitized emission and Frequency Domain-Fluorescence Lifetime Imaging Microscopy (FD-FLIM. For FRET-FLIM, a prototype Modulated Electron-Multiplied FLIM system was used, which is, to the best of our knowledge, the first account of Frequency Domain FLIM to analyze FRET in single bacterial cells. To perform FRET-FLIM, we first determined and benchmarked the best fluorescent protein-pair for FRET in Bacillus subtilis using a novel BglBrick-compatible integration vector. We show that GFP-tagRFP is an excellent donor-acceptor pair for B. subtilis in vivo FRET studies. As a proof of concept, selected donor and acceptor fluorescent proteins were fused using a linker that contained a tobacco etch virus (TEV-protease recognition sequence. Induction of TEV-protease results in loss of FRET efficiency and increase in fluorescence lifetime. The loss of FRET efficiency after TEV induction can be followed in time in single cells via time-lapse microscopy. This work will facilitate future studies of in vivo dynamics of protein complexes in single B. subtilis cells.

  19. Friction and wear calculation methods

    CERN Document Server

    Kragelsky, I V; Kombalov, V S

    1981-01-01

    Friction and Wear: Calculation Methods provides an introduction to the main theories of a new branch of mechanics known as """"contact interaction of solids in relative motion."""" This branch is closely bound up with other sciences, especially physics and chemistry. The book analyzes the nature of friction and wear, and some theoretical relationships that link the characteristics of the processes and the properties of the contacting bodies essential for practical application of the theories in calculating friction forces and wear values. The effect of the environment on friction and wear is a

  20. Wear of polymers and composites

    CERN Document Server

    Abdelbary, Ahmed

    2015-01-01

    In the field of tribology, the wear behaviour of polymers and composite materials is considered a highly non-linear phenomenon. Wear of Polymers and Composites introduces fundamentals of polymers and composites tribology. The book suggests a new approach to explore the effect of applied load and surface defects on the fatigue wear behaviour of polymers, using a new tribometer and thorough experiments. It discusses effects of surface cracks, under different static and cyclic loading parameters on wear, and presents an intelligent algorithm, in the form of a neural network, to map the relations

  1. In vitro ageing and wear behaviour of ceria stabilized zirconia toughened alumina (CSZ-TA) bio-ceramic

    Energy Technology Data Exchange (ETDEWEB)

    Pandey, Ajoy Kumar; Jena, Usha Rani; Biswas, Koushik, E-mail: k_biswas@metal.iitkgp.ernet.in

    2014-08-01

    15–25 wt% zirconia (stabilized with 14 mol% ceria) toughened alumina was synthesized by co-precipitation technique. The synthesized powders were calcined at different temperatures, compacted and conventionally sintered following two steps sintering process. Uniformly distributed submicron sized grains with Vickers' hardness value up to 1730±6HV20 were achieved after conventional sintering. In order to assess the ageing behaviour, samples were hydrothermally treated (in vitro) at 134 °C under 0.2 MPa in presence of simulated body fluid. Rietveld refinement of the X-ray diffraction patterns was carried out to estimate the phase content after calcination, sintering and after different stages of hydrothermal treatment. No significant phase change (only ∼3%) was observed even after 100 h of hydrothermal treatment. Very few bulged grains (resulted from the tetragonal to monoclinic phase transformation) on the surface and slight decrease in hardness value were observed after hydrothermal treatment. Fretting wear in dry condition was carried out taking ball on flat geometry for 10{sup 5} cycles at different loads before and after hydrothermal treatment. Wear volumes were directly estimated from the surface scanning of the wear scar using profilometer. Transition of wear and its related mechanisms at different loads along with the effect of ageing on wear were discussed. - Highlights: • Ceria stabilized zirconia toughened alumina was developed. • Ageing behaviour of developed materials was studied through hydrothermal treatment. • Phase transformation during ageing was characterized through Rietveld refinement. • Only 3% phase transformation was observed even after 100 h hydrothermal treatment. • Fretting wear volume before band after hydrothermal treatment were estimated.

  2. Fretting Fatigue Behavior of Nickel Alloy IN-100

    Science.gov (United States)

    2006-03-01

    K., B. F. Dyson, and M. McLean. “Tension-Compression Creep Asym- metry In a Turbine Disc Superalloy : Roles of Internal Stress and Thermal Age- ing...understand the fretting phenomenon and its mechanisms, but only a few have been performed on nickel-based alloys. This superalloy is considered one...excellent magnetic properties, but only at low magnetic induction. Nowadays, the need for the use of high-strength nickel-based superalloys in

  3. Dual Readout BRET/FRET Sensors for Measuring Intracellular Zinc

    Science.gov (United States)

    2016-01-01

    Genetically encoded FRET-based sensor proteins have significantly contributed to our current understanding of the intracellular functions of Zn2+. However, the external excitation required for these fluorescent sensors can give rise to photobleaching and phototoxicity during long-term imaging, limits applications that suffer from autofluorescence and light scattering, and is not compatible with light-sensitive cells. For these applications, sensor proteins based on Bioluminescence Resonance Energy Transfer (BRET) would provide an attractive alternative. In this work, we used the bright and stable luciferase NanoLuc to create the first genetically encoded BRET sensors for measuring intracellular Zn2+. Using a new sensor approach, the NanoLuc domain was fused to the Cerulean donor domain of two previously developed FRET sensors, eCALWY and eZinCh-2. In addition to preserving the excellent Zn2+ affinity and specificity of their predecessors, these newly developed sensors enable both BRET- and FRET-based detection. While the dynamic range of the BRET signal for the eCALWY-based BLCALWY-1 sensor was limited by the presence of two competing BRET pathways, BRET/FRET sensors based on the eZinCh-2 scaffold (BLZinCh-1 and -2) yielded robust 25–30% changes in BRET ratio. In addition, introduction of a chromophore-silencing mutation resulted in a BRET-only sensor (BLZinCh-3) with increased BRET response (50%) and an unexpected 10-fold increase in Zn2+ affinity. The combination of robust ratiometric response, physiologically relevant Zn2+ affinities, and stable and bright luminescence signal offered by the BLZinCh sensors allowed monitoring of intracellular Zn2+ in plate-based assays as well as intracellular BRET-based imaging in single living cells in real time. PMID:27547982

  4. Fretting corrosion in power contacts: Electrical and thermal analysis

    OpenAIRE

    El Mossouess, S; Benjemâa, N; Carvou, E; El Abdi, R; Benmamas, L; Doublet, L

    2014-01-01

    International audience; -Fretting corrosion phenomenon is known as the main cause of contact resistance increasing in signal contact. But for power connectors this undesirable phenomenon in embarked systems is more complex because high current induces high voltages and subsequent Joule overheating can be expected during vibration. Our study deals with contact similar of power connectors ones submitted to vibration am-plitudes up to 25 micrometres at frequencies of a few 10Hz under a current r...

  5. Distinguishing the cross-beta spine arrangements in amyloid fibrils using FRET analysis.

    Science.gov (United States)

    Deng, Wei; Cao, Aoneng; Lai, Luhua

    2008-06-01

    The recently published microcrystal structures of amyloid fibrils from small peptides greatly enhanced our understanding of the atomic-level structure of the amyloid fibril. However, only a few amyloid fibrils can form microcrystals. The dansyl-tryptophan fluorescence resonance energy transfer (FRET) pair was shown to be able to detect the inter-peptide arrangement of the Transthyretin (105-115) amyloid fibril. In this study, we combined the known microcrystal structures with the corresponding FRET efficiencies to build a model for amyloid fibril structure classification. We found that fibrils with an antiparallel structural arrangement gave the largest FRET signal, those with a parallel arrangement gave the lowest FRET signal, and those with a mixed arrangement gave a moderate FRET signal. This confirms that the amyloid fibril structure patterns can be classified based on the FRET efficiency.

  6. Rise-Time of FRET-Acceptor Fluorescence Tracks Protein Folding

    Science.gov (United States)

    Lindhoud, Simon; Westphal, Adrie H.; van Mierlo, Carlo P. M.; Visser, Antonie J. W. G.; Borst, Jan Willem

    2014-01-01

    Uniform labeling of proteins with fluorescent donor and acceptor dyes with an equimolar ratio is paramount for accurate determination of Förster resonance energy transfer (FRET) efficiencies. In practice, however, the labeled protein population contains donor-labeled molecules that have no corresponding acceptor. These FRET-inactive donors contaminate the donor fluorescence signal, which leads to underestimation of FRET efficiencies in conventional fluorescence intensity and lifetime-based FRET experiments. Such contamination is avoided if FRET efficiencies are extracted from the rise time of acceptor fluorescence upon donor excitation. The reciprocal value of the rise time of acceptor fluorescence is equal to the decay rate of the FRET-active donor fluorescence. Here, we have determined rise times of sensitized acceptor fluorescence to study the folding of double-labeled apoflavodoxin molecules and show that this approach tracks the characteristics of apoflavodoxinʼs complex folding pathway. PMID:25535076

  7. Fatigue, Wear and Cracking of Dental Materials

    Directory of Open Access Journals (Sweden)

    Traian Eugen Bolfa

    2015-07-01

    Full Text Available Evaluation of the method of failure and crack propagation in dental metals, ceramics and polymer composite materials associated with occlusal activity are associated with contact, twisting and sliding modes. Such loads can result in various combinations of damage due to fatigue and wear. In order to increase sustainability and longevity the dental materials must demonstrate sufficient strength to dynamic stresses. In the case of masticatory forces associated with high contact tensions, the contact area of the superficial layer is under a state of specialcomplex voltage. Variations in the material or the structure, impurities, scratches and voids can directly influence the structural integrity of the material and result in microscopic cracks. These cracks propagate under repeated cyclic loading leading to dental restoration failure.

  8. pyFRET: A Python Library for Single Molecule Fluorescence Data Analysis

    OpenAIRE

    Murphy, Rebecca R.; Jackson, Sophie E.; Klenerman, David

    2014-01-01

    Single molecule F\\"orster resonance energy transfer (smFRET) is a powerful experimental technique for studying the properties of individual biological molecules in solution. However, as adoption of smFRET techniques becomes more widespread, the lack of available software, whether open source or commercial, for data analysis, is becoming a significant issue. Here, we present pyFRET, an open source Python package for the analysis of data from single-molecule fluorescence experiments from freely...

  9. Rise-time of FRET-acceptor fluorescence tracks protein folding

    OpenAIRE

    Simon Lindhoud; Adrie H. Westphal; van Mierlo, Carlo P. M.; Visser, Antonie J. W. G.; Jan Willem Borst

    2014-01-01

    Uniform labeling of proteins with fluorescent donor and acceptor dyes with an equimolar ratio is paramount for accurate determination of Förster resonance energy transfer (FRET) efficiencies. In practice, however, the labeled protein population contains donor-labeled molecules that have no corresponding acceptor. These FRET-inactive donors contaminate the donor fluorescence signal, which leads to underestimation of FRET efficiencies in conventional fluorescence intensity and lifetime-based F...

  10. A Multicolor Single-Molecule FRET Approach to Study Protein Dynamics and Interactions Simultaneously.

    Science.gov (United States)

    Götz, M; Wortmann, P; Schmid, S; Hugel, T

    2016-01-01

    Single-molecule Förster resonance energy transfer (smFRET) is a versatile tool for studying biomolecules in a quantitative manner. Multiple conformations within and interactions between biomolecules can be detected and their kinetics can be determined. Thus, smFRET has become an essential tool in enzymology. Ordinary two-color smFRET experiments can provide only limited insight into the function of biological systems, which commonly consist of more than two components. A complete understanding of complex multicomponent biological systems requires correlated information on conformational rearrangements on the one hand and transient interactions with binding partners on the other. Multicolor smFRET experiments enable the direct observation of such correlated dynamics and interactions. Here we demonstrate the power and limitations of multicolor smFRET experiments including the description of a multicolor smFRET setup and data analysis. A general analytical procedure for multicolor smFRET data is presented and applied to the multicomponent heat shock protein 90 system. This allows us to identify microscopic states in transient complexes. Conformational dynamics and nucleotide binding are simultaneously detected, which is impossible using two-color smFRET. Additionally, their correlation is quantified using 3D ensemble hidden Markov analysis, in and out of equilibrium. This method is perfectly suited for protein systems that are much more sophisticated than previously studied DNA-based systems. By extending the application to biologically relevant systems, multicolor smFRET comes of age and provides a unique mechanistic insight into protein machines.

  11. A communication theoretical analysis of FRET-based mobile ad hoc molecular nanonetworks.

    Science.gov (United States)

    Kuscu, Murat; Akan, Ozgur B

    2014-09-01

    Nanonetworks refer to a group of nanosized machines with very basic operational capabilities communicating to each other in order to accomplish more complex tasks such as in-body drug delivery, or chemical defense. Realizing reliable and high-rate communication between these nanomachines is a fundamental problem for the practicality of these nanonetworks. Recently, we have proposed a molecular communication method based on Förster Resonance Energy Transfer (FRET) which is a nonradiative excited state energy transfer phenomenon observed among fluorescent molecules, i.e., fluorophores. We have modeled the FRET-based communication channel considering the fluorophores as single-molecular immobile nanomachines, and shown its reliability at high rates, and practicality at the current stage of nanotechnology. In this study, for the first time in the literature, we investigate the network of mobile nanomachines communicating through FRET. We introduce two novel mobile molecular nanonetworks: FRET-based mobile molecular sensor/actor nanonetwork (FRET-MSAN) which is a distributed system of mobile fluorophores acting as sensor or actor node; and FRET-based mobile ad hoc molecular nanonetwork (FRET-MAMNET) which consists of fluorophore-based nanotransmitter, nanoreceivers and nanorelays. We model the single message propagation based on birth-death processes with continuous time Markov chains. We evaluate the performance of FRET-MSAN and FRET-MAMNET in terms of successful transmission probability and mean extinction time of the messages, system throughput, channel capacity and achievable communication rates.

  12. Understanding and modeling Förster-type resonance energy transfer (FRET)

    CERN Document Server

    Hernández Martínez, Pedro Ludwig; Demir, Hilmi Volkan

    2017-01-01

    This Brief presents a complete study of the generalized theory of Förster-type energy transfer in nanostructures with mixed dimensionality. Here the aim is to obtain a generalized theory of FRET including a comprehensive set of analytical equations for all combinations and configurations of nanostructures and deriving generic expressions for the dimensionality involved. In this brief, the modification of FRET mechanism with respect to the nanostructure serving as the donor vs. the acceptor will be included, focusing on the rate’s distance dependency and the role of the effective dielectric function in FRET, which will be a unique, useful source for those who study and model FRET.

  13. Wear of micro end mills

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    This paper addresses the important issue of wear on micro end mills considering relevant metrological tools for its characterization and quantification. Investigation of wear on micro end mills is particularly difficult and no data are available in the literature. Small worn volumes cause large d...

  14. [Infants wearing teething necklaces].

    Science.gov (United States)

    Taillefer, A; Casasoprana, A; Cascarigny, F; Claudet, I

    2012-10-01

    Numerous infants wear teething necklaces, a quack remedy with a real risk of strangulation or aspiration of small beads. Evaluate parental perceptions and beliefs about the use of teething necklaces and analyze parental knowledge about the associated dangers. Between March and July 2011, in three different pediatric units of a tertiary children's hospital and a general hospital in Toulouse and Montauban (southwest France), voluntary parents were invited to be interviewed about their child wearing a teething necklace. The interviews were conducted following an anthropological approach: they were recorded and then fully transcribed and analyzed. Parents were informed that the conversation was recorded. During the study period, 48 children were eligible. Eleven families refused to participate, 29 parents were interviewed face to face. The children's mean age was 14 years ± 7 months, the male:female ratio was equal to 0.8 (12 boys, 15 girls). The mean age of children when necklace wearing was started was equal to 4 ± 2 months. The mean mother's age was 31 ± 5 years and 33 ± 4 years for fathers. The parents' religion was mostly Catholic (60%). Teething necklaces were mainly made of amber (n=23). Sales information about the risks associated with the necklaces was for the most part absent (92%). The most frequent positive parental perceptions were analgesic properties and a soothing remedy (73%); a birth accessory and memory (64%); an esthetic accessory (60%); a protective amulet (60%); and an alternative or additional element to other traditional therapeutics (55%). The negative parental perceptions (n=4) were an unnecessary accessory, costume jewelry, a pure commercial abuse of a popular belief, a dangerous item with a risk of strangulation, and the absence of proof of its efficacy. Although parents concede that teeth eruption is benign, they fear its related symptoms. To a natural phenomenon a natural response: they use a necklace to satisfy the analogy. The

  15. AccPbFRET: An ImageJ plugin for semi-automatic, fully corrected analysis of acceptor photobleaching FRET images

    Directory of Open Access Journals (Sweden)

    Vereb György

    2008-08-01

    Full Text Available Abstract Background The acceptor photobleaching fluorescence resonance energy transfer (FRET method is widely used for monitoring molecular interactions in cells. This method of FRET, while among those with the simplest mathematics, is robust, self-controlled and independent of fluorophore amounts and ratios. Results AccPbFRET is a user-friendly, efficient ImageJ plugin which allows fully corrected, pixel-wise calculation and detailed, ROI (region of interest-based analysis of FRET efficiencies in microscopic images. Furthermore, automatic registration and semi-automatic analysis of large image sets is provided, which are not available in any existing FRET evaluation software. Conclusion Despite of the widespread applicability of the acceptor photobleaching FRET technique, this is the first paper where all possible sources of major errors of the measurement and analysis are considered, and AccPbFRET is the only program which provides the complete suite of corrections – for registering image pairs, for unwanted photobleaching of the donor, for cross-talk of the acceptor and/or its photoproduct to the donor channel and for partial photobleaching of the acceptor. The program efficiently speeds up the analysis of large image sets even for novice users and is freely available.

  16. Fretting Damage of ACSR Conductor Enwrapped with Aluminium Armour Tape%铝包带包裹高压输电线路导线的微动损伤

    Institute of Scientific and Technical Information of China (English)

    陈国宏; 王煦; 王家庆; 刘俊建; 张涛; 汤文明

    2012-01-01

    Abstract : Fretting experirr, ent of the aluminum conductor steel reinforced (ACSR) conductor enwrapped with aluminium armour tape was carried out using a conductor fretting testing equipment made by the authors. After fretting for 2.0X 10r cycles at an amplitude of 1.0 ram, fretting damage of the external and internal A] strands and steel core strands of the conductor was investigated, and the tensile strengths of them were also measured. Moreover, the fretting damage mechanism of the enwrapped conductor was discussed. The results showed that the external A] strands were injured by the scratch of the aluminium armour tape and the abrasive wear. The wear marks of the internal A1 strands were all elliptical, partially, there were fatigue cracks under them. The steel core strands were slightly damaged, only adhesion wear and piece deprivation of the galvanized zinc layer took place. The aluminium armour tape could effectively protect the ACSR conductor, so that the internal and external A1 strands of the enwrapped conductor had higher tensile strengths than those of the unenwrapped conductor.%在自制的微动试验装置上对铝包带包裹钢芯铝绞导线(ACSR)进行微动试验研究。振幅1.0mm,2.0×107次微动循环后,研究内、外层铝股线及钢芯线的磨损状况,测定其抗拉强度,探讨铝包带包裹导线的微动损伤机制。结果表明:外层铝股线表面经受铝包带的刮擦以及磨粒磨损;内层铝股线微动磨损斑呈椭圆形,部分磨损斑下有疲劳裂纹;而钢芯线的损伤微弱,仅发生镀锌层的磨损、脱落。铝包带对导线有较好的保护作用,内外层铝股线的抗拉强度均高于未包裹导线的抗拉强度。

  17. Time between failures model and failure analysis of CNC system

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hai-bo; JIA Ya-zhou; ZHOU Guang-wen

    2007-01-01

    To provide basis for the reliability improvement design of CNC system, the failure data of a type of CNC system in one year are collected under field conditions in workshops. The distribution model parameters of time between failures are estimated by least square method and hypothesis testing is done by d-test method. It is proved that the time between failures of the CNC system follows Weibull distribution and the system has entered into the wear-out failure period. The failure positions and failure causes are analyzed further to indicate the weak subsystems of the CNC system. It can be found that servo unit, electrical system, detecting unit and power supply are principal failure positions and the main failure cause is breakage of components. The corresponding improvement measures are put forward. The paper provides a reference to reliability design and analysis of CNC system for the manufacturer and has great guidance to using and maintaining CNC system for the user.

  18. Mechanisms for fatigue and wear of polysilicon structural thinfilms

    Energy Technology Data Exchange (ETDEWEB)

    Alsem, Daniel Henricus [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    Fatigue and wear in micron-scale polysilicon structural films can severely impact the reliability of microelectromechanical systems (MEMS). Despite studies on fatigue and wear behavior of these films, there is still an on-going debate regarding the precise physical mechanisms for these two important failure modes. Although macro-scale silicon does not fatigue, this phenomenon is observed in micron-scale silicon. It is shown that for polysilicon devices fabricated in the MUMPs foundry and SUMMiT process stress-lifetime data exhibits similar trends in ambient air, shorter lifetimes in higher relative humidity environments and no fatigue failure at all in high vacuum. Transmission electron microscopy of the surface oxides of the samples show an approximate four-fold thickening of the oxide at stress concentrations after fatigue failure, but no thickening after fracture in air or after fatigue cycling in vacuo. It is found that such oxide thickening and fatigue failure (in air) occurs in devices with initial oxide thicknesses of ~4-20 nm. Such results are interpreted and explained by a reaction layer fatigue mechanism; specifically, moisture-assisted subcritical cracking within a cyclic stress-assisted thickened oxide layer occurs until the crack reaches a critical size to cause catastrophic failure. Polysilicon specimens from the SUMMiT process are used to study wear mechanisms in micron-scale silicon in ambient air. Worn parts are examined by analytical scanning and transmission electron microscopy, while temperature changes are monitored using infrared microscopy. These results are compared with the development of values of static coefficients of friction (COF) with number of wear cycles. Observations show amorphous debris particles (~50-100 nm) created by fracture through the silicon grains (~500 nm), which subsequently oxidize, agglomerate into clusters and create plowing tracks. A nano-crystalline layer (~20-200 nm) forms at worn regions. No dislocations or

  19. FRET and colocalization analyzer--a method to validate measurements of sensitized emission FRET acquired by confocal microscopy and available as an ImageJ Plug-in.

    Science.gov (United States)

    Hachet-Haas, Muriel; Converset, Noël; Marchal, Olivier; Matthes, Hans; Gioria, Sophie; Galzi, Jean-Luc; Lecat, Sandra

    2006-12-01

    Fluorescence resonance energy transfer (FRET) between an adequate pair of fluorophores is an indication of closer proximity than colocalization and is used by biologists to study fluorescently modified protein interactions inside cells. We present a method for visualization of FRET images acquired by confocal sensitized emission, involving excitation of the donor fluorophore and detection of the energy transfer as an emission from the acceptor fluorophore into the FRET channel. Authentic FRET signal measurements require the correction from the FRET channel of the undesired bleed-through signals (BT) resulting from both the leak-through of the donor emission and the direct acceptor emission. Our method reduces the interference of the user to a minimum by analyzing the entire image, pixel by pixel. It proposes imaging treatments and the display of control images to validate the BT calculation and the image corrections. It displays FRET images as a function of the colocalization of the two fluorescent partners. Finally, it proposes an alternative to normalization of the FRET intensities to compare FRET signal variations between samples. This method called "FRET and Colocalization Analyzer" has been implemented in a Plug-in of the freely available ImageJ software. It is particularly adapted when transient expression of the fluorescent proteins is used thereby giving very variable expression levels or when the colocalization of the two partners is varying in proportion, in amount, and in size, as a function of time. The method and program are validated using the analysis of the spatio-temporal interactions between a G-protein coupled receptor, the tachykinin NK2 receptor, and the beta-arrestin 2 as an example.

  20. Switch wear leveling

    Science.gov (United States)

    Wu, Hunter; Sealy, Kylee; Gilchrist, Aaron

    2015-09-01

    An apparatus for switch wear leveling includes a switching module that controls switching for two or more pairs of switches in a switching power converter. The switching module controls switches based on a duty cycle control technique and closes and opens each switch in a switching sequence. The pairs of switches connect to a positive and negative terminal of a DC voltage source. For a first switching sequence a first switch of a pair of switches has a higher switching power loss than a second switch of the pair of switches. The apparatus includes a switch rotation module that changes the switching sequence of the two or more pairs of switches from the first switching sequence to a second switching sequence. The second switch of a pair of switches has a higher switching power loss than the first switch of the pair of switches during the second switching sequence.

  1. Low friction wear resistant graphene films

    Science.gov (United States)

    Sumant, Anirudha V.; Berman, Diana; Erdemir, Ali

    2017-02-07

    A low friction wear surface with a coefficient of friction in the superlubric regime including graphene and nanoparticles on the wear surface is provided, and methods of producing the low friction wear surface are also provided. A long lifetime wear resistant surface including graphene exposed to hydrogen is provided, including methods of increasing the lifetime of graphene containing wear surfaces by providing hydrogen to the wear surface.

  2. Mining the Sinorhizobium meliloti transportome to develop FRET biosensors for sugars, dicarboxylates and cyclic polyols.

    Directory of Open Access Journals (Sweden)

    Alexandre Bourdès

    Full Text Available Förster resonance energy transfer (FRET biosensors are powerful tools to detect biologically important ligands in real time. Currently FRET bisosensors are available for twenty-two compounds distributed in eight classes of chemicals (two pentoses, two hexoses, two disaccharides, four amino acids, one nucleobase, two nucleotides, six ions and three phytoestrogens. To expand the number of available FRET biosensors we used the induction profile of the Sinorhizobium meliloti transportome to systematically screen for new FRET biosensors.Two new vectors were developed for cloning genes for solute-binding proteins (SBPs between those encoding FRET partner fluorescent proteins. In addition to a vector with the widely used cyan and yellow fluorescent protein FRET partners, we developed a vector using orange (mOrange2 and red fluorescent protein (mKate2 FRET partners. From the sixty-nine SBPs tested, seven gave a detectable FRET signal change on binding substrate, resulting in biosensors for D-quinic acid, myo-inositol, L-rhamnose, L-fucose, β-diglucosides (cellobiose and gentiobiose, D-galactose and C4-dicarboxylates (malate, succinate, oxaloacetate and fumarate. To our knowledge, we describe the first two FRET biosensor constructs based on SBPs from Tripartite ATP-independent periplasmic (TRAP transport systems.FRET based on orange (mOrange2 and red fluorescent protein (mKate2 partners allows the use of longer wavelength light, enabling deeper penetration of samples at lower energy and increased resolution with reduced back-ground auto-fluorescence. The FRET biosensors described in this paper for four new classes of compounds; (i cyclic polyols, (ii L-deoxy sugars, (iii β-linked disaccharides and (iv C4-dicarboxylates could be developed to study metabolism in vivo.

  3. Enhancing the wear resistance of case carburized steel (En 353) by cryogenic treatment

    Science.gov (United States)

    Bensely, A.; Prabhakaran, A.; Mohan Lal, D.; Nagarajan, G.

    2005-12-01

    All mechanical components that undergo sliding or rolling contact are subject to some degree of wear. So wear is an important tribological phenomenon while studying the failure of components. The observed frequent failure of crown and pinion due to wear and fatigue lead to this study on effect of cryogenic treatment on the wear resistance of case carburized steel (En 353). This paper deals with the pin on disk wear test without lubrication as per ASTM standard, designation: G 99-95A. The test was carried out for three different load conditions and seven sliding speeds for the samples, which has undergone three different treatment conditions namely conventional heat treatment (CHT), shallow cryogenic treatment (SCT) and deep cryogenic treatment (DCT). It has been found that the wear resistance has been considerably increased due to shallow cryogenic treatment and deep cryogenic treatment includes much more improvement in wear resistance when compared to conventional heat treatment. Also it is concluded that for better wear resistance, it is advisable to go for deep cryogenic treatment. The results are consistent with the previous studies reported in the literature on cryogenic treatments for other materials.

  4. Tool wear mechanism in turning of novel wear-resisting aluminum bronze

    Institute of Scientific and Technical Information of China (English)

    倪东惠; 夏伟; 张大童; 郭国文; 邵明

    2003-01-01

    Tool wear and wear mechanism during the turning of a wear-resisting aluminum bronze have been stud-ied. Tool wear samples were prepared by using M2 high-speed steel and YW1 cemented carbide tools to turn a novelhigh strength, wear resisting aluminum bronze without coolant and lubricant. Adhesion of workpiece materials wasfound on tool's surface. Under the turning condition used in this study major wear mechanisms for turning aluminumbronze using M2 high-speed steel tool are diffusion wear, adhesive wear and plastic deformation and shear on thecrater. Partial melting of high-speed steel on the rake plays a role in the tool wear also. Major wear mechanisms forturning aluminum bronze using YW1 cemented carbide tool are diffusion wear, attrition wear and sliding wear. Tocontrol the machining temperature is essential to reduce tool wear.

  5. Evaluating the Relationship between FRET Changes and Distance Changes Using DNA Length and Restriction Enzyme Specificity

    Science.gov (United States)

    Pazhani, Yogitha; Horn, Abigail E.; Grado, Lizbeth; Kugel, Jennifer F.

    2016-01-01

    FRET (Fo¨rster resonance energy transfer) involves the transfer of energy from an excited donor fluorophore to an acceptor molecule in a manner that is dependent on the distance between the two. A biochemistry laboratory experiment is described that teaches students how to use FRET to evaluate distance changes in biological molecules. Students…

  6. FRET Imaging Trackable Long-Circulating Biodegradable Nanomedicines for Ovarian Cancer Therapy

    Science.gov (United States)

    2014-09-01

    Award Number: W81XWH-13-1-0160 TITLE: FRET Imaging Trackable Long-Circulating Biodegradable ...TITLE AND SUBTITLE FRET Imaging Trackable Long-Circulating Biodegradable Nanomedicines for Ovarian Cancer Therapy 5a. CONTRACT NUMBER...strategy, which permits visualizing the biodegradation of copolymer-drug conjugates at the body, tissue and cell levels in real time. The information

  7. Lateral diffusion contributes to FRET from lanthanide-tagged membrane proteins

    Energy Technology Data Exchange (ETDEWEB)

    Lan, Tien-Hung; Wu, Guangyu; Lambert, Nevin A., E-mail: nelambert@gru.edu

    2015-08-14

    Diffusion can enhance Förster resonance energy transfer (FRET) when donors or acceptors diffuse distances that are similar to the distances separating them during the donor's excited state lifetime. Lanthanide donors remain in the excited state for milliseconds, which makes them useful for time-resolved FRET applications but also allows time for diffusion to enhance energy transfer. Here we show that diffusion dramatically enhances FRET between membrane proteins labeled with lanthanide donors. This phenomenon complicates interpretation of experiments that use long-lived donors to infer association or proximity of mobile membrane proteins, but also offers a method of monitoring diffusion in membrane domains in real time in living cells. - Highlights: • Diffusion enhances TR-FRET from membrane proteins labeled with lanthanide donors. • Diffusion-dependent FRET can overshadow FRET due to oligomerization or clustering. • FRET studies using lanthanide-tagged membrane proteins should consider diffusion. • FRET from lanthanide donors can be used to monitor membrane protein diffusion.

  8. Multifunctional Concentric FRET-Quantum Dot Probes for Tracking and Imaging of Proteolytic Activity.

    Science.gov (United States)

    Massey, Melissa; Li, Jia Jun; Algar, W Russ

    2017-01-01

    Proteolysis has many important roles in physiological regulation. It is involved in numerous cell signaling processes and the pathogenesis of many diseases, including cancers. Methods of visualizing and assaying proteolytic activity are therefore in demand. Förster resonance energy transfer (FRET) probes offer several advantages in this respect. FRET supports end-point or real-time measurements, does not require washing or separation steps, and can be implemented in various assay or imaging formats. In this chapter, we describe methodology for preparing self-assembled concentric FRET (cFRET) probes for multiplexed tracking and imaging of proteolytic activity. The cFRET probe comprises a green-emitting semiconductor quantum dot (QD) conjugated with multiple copies of two different peptide substrates for two target proteases. The peptide substrates are labeled with different fluorescent dyes, Alexa Fluor 555 and Alexa Fluor 647, and FRET occurs between the QD and both dyes, as well as between the two dyes. This design enables a single QD probe to track the activity of two proteases simultaneously. Fundamental cFRET theory is presented, and procedures for using the cFRET probe for quantitative measurement of the activity of two model proteases are given, including calibration, fluorescence plate reader or microscope imaging assays, and data analysis. Sufficient detail is provided for other researchers to adapt this method to their specific requirements and proteolytic systems of interest.

  9. Engineering of weak helper interactions for high-efficiency FRET probes.

    Science.gov (United States)

    Grünberg, Raik; Burnier, Julia V; Ferrar, Tony; Beltran-Sastre, Violeta; Stricher, François; van der Sloot, Almer M; Garcia-Olivas, Raquel; Mallabiabarrena, Arrate; Sanjuan, Xavier; Zimmermann, Timo; Serrano, Luis

    2013-10-01

    Fluorescence resonance energy transfer (FRET)-based detection of protein interactions is limited by the very narrow range of FRET-permitting distances. We show two different strategies for the rational design of weak helper interactions that co-recruit donor and acceptor fluorophores for a more robust detection of bimolecular FRET: (i) in silico design of electrostatically driven encounter complexes and (ii) fusion of tunable domain-peptide interaction modules based on WW or SH3 domains. We tested each strategy for optimization of FRET between (m)Citrine and mCherry, which do not natively interact. Both approaches yielded comparable and large increases in FRET efficiencies with little or no background. Helper-interaction modules can be fused to any pair of fluorescent proteins and could, we found, enhance FRET between mTFP1 and mCherry as well as between mTurquoise2 and mCitrine. We applied enhanced helper-interaction FRET (hiFRET) probes to study the binding between full-length H-Ras and Raf1 as well as the drug-induced interaction between Raf1 and B-Raf.

  10. Surface roughness and wear of resin cements after toothbrush abrasion

    Directory of Open Access Journals (Sweden)

    Sérgio Kiyoshi ISHIKIRIAMA

    2015-01-01

    Full Text Available Increased surface roughness and wear of resin cements may cause failure of indirect restorations. The aim of this study was to evaluate quantitatively the surface roughness change and the vertical wear of four resin cements subjected to mechanical toothbrushing abrasion. Ten rectangular specimens (15 × 5 × 4 mm were fabricated according to manufacturer instructions for each group (n = 10: Nexus 3, Kerr (NX3; RelyX ARC, 3M ESPE (ARC; RelyX U100, 3M ESPE (U100; and Variolink II, Ivoclar/Vivadent (VL2. Initial roughness (Ra, µm was obtained through 5 readings with a roughness meter. Specimens were then subjected to toothbrushing abrasion (100,000 cycles, and further evaluation was conducted for final roughness. Vertical wear (µm was quantified by 3 readings of the real profile between control and brushed surfaces. Data were subjected to analysis of variance, followed by Tukey’s test (p < 0.05. The Pearson correlation test was performed between the surface roughness change and wear (p < 0.05. The mean values of initial/final roughness (Ra, µm/wear (µm were as follows: NX3 (0.078/0.127/23.175; ARC (0.086/0.246/20.263; U100 (0.296/0.589/16.952; and VL2 (0.313/0.512/22.876. Toothbrushing abrasion increased surface roughness and wear of all resin cements tested, although no correlation was found between those variables. Vertical wear was similar among groups; however, it was considered high and may lead to gap formation in indirect restorations.

  11. Influence of Cycle Temperature on the Wear Resistance of Vermicular Iron Derivatized with Bionic Surfaces

    Science.gov (United States)

    Sui, Qi; Zhang, Peng; Zhou, Hong; Liu, Yan; Ren, Luquan

    2016-11-01

    Depending on their applications, such as in brake discs, camshafts, etc., the wear behavior of vermicular iron is influenced by the thermal cycling regime. The failure of a working part during its service life is a consequence of both thermal fatigue and wear. Previously, the wear and thermal fatigue resistance properties of vermicular iron were separately investigated by researchers, rather than a study combining these two factors. In the present work, the effect of cycle temperature on the wear resistance of specimens with bionic units processed by laser has been investigated experimentally. The wear behavior pre- and post-thermal cycling has also been investigated, and the influence of different cycle temperatures on the wear resistance is discussed. The results indicate that the thermal cycling regime brought about negative influences with varying degrees, on the material properties, such as the microstructures, micro-hardness, cracks, and oxidation resistance properties. All these factors synergistically reduced the wear resistance of vermicular iron. In particular, the negative influence apparently increased with an increase in cycle temperature. Nevertheless, the post-thermal-cycle wear resistance of the specimens with bionic units was superior to those without bionic units. Hence, the laser bionic process is an effective way to improve the performance of vermicular iron in combined thermal cycling and wear service conditions.

  12. A Versatile Multiple Target Detection System Based on DNA Nano-assembled Linear FRET Arrays.

    Science.gov (United States)

    Li, Yansheng; Du, Hongwu; Wang, Wenqian; Zhang, Peixun; Xu, Liping; Wen, Yongqiang; Zhang, Xueji

    2016-05-27

    DNA molecules have been utilized both as powerful synthetic building blocks to create nanoscale architectures and as inconstant programmable templates for assembly of biosensors. In this paper, a versatile, scalable and multiplex detection system is reported based on an extending fluorescent resonance energy transfer (FRET) cascades on a linear DNA assemblies. Seven combinations of three kinds of targets are successfully detected through the changes of fluorescence spectra because of the three-steps FRET or non-FRET continuity mechanisms. This nano-assembled FRET-based nanowire is extremely significant for the development of rapid, simple and sensitive detection system. The method used here could be extended to a general platform for multiplex detection through more-step FRET process.

  13. pyFRET: A Python Library for Single Molecule Fluorescence Data Analysis

    CERN Document Server

    Murphy, Rebecca R; Klenerman, David

    2014-01-01

    Single molecule F\\"orster resonance energy transfer (smFRET) is a powerful experimental technique for studying the properties of individual biological molecules in solution. However, as adoption of smFRET techniques becomes more widespread, the lack of available software, whether open source or commercial, for data analysis, is becoming a significant issue. Here, we present pyFRET, an open source Python package for the analysis of data from single-molecule fluorescence experiments from freely diffusing biomolecules. The package provides methods for the complete analysis of a smFRET dataset, from burst selection and denoising, through data visualisation and model fitting. We provide support for both continuous excitation and alternating laser excitation (ALEX) data analysis. pyFRET is available as a package downloadable from the Python Package Index (PyPI) under the open source three-clause BSD licence, together with links to extensive documentation and tutorials, including example usage and test data. Additio...

  14. Imaging of Metabolic Status in 3D Cultures with an Improved AMPK FRET Biosensor for FLIM

    Directory of Open Access Journals (Sweden)

    George Chennell

    2016-08-01

    Full Text Available We describe an approach to non-invasively map spatiotemporal biochemical and physiological changes in 3D cell culture using Forster Resonance Energy Transfer (FRET biosensors expressed in tumour spheroids. In particular, we present an improved Adenosine Monophosphate (AMP Activated Protein Kinase (AMPK FRET biosensor, mTurquoise2 AMPK Activity Reporter (T2AMPKAR, for fluorescence lifetime imaging (FLIM readouts that we have evaluated in 2D and 3D cultures. Our results in 2D cell culture indicate that replacing the FRET donor, enhanced Cyan Fluorescent Protein (ECFP, in the original FRET biosensor, AMPK activity reporter (AMPKAR, with mTurquoise2 (mTq2FP, increases the dynamic range of the response to activation of AMPK, as demonstrated using the direct AMPK activator, 991. We demonstrated 3D FLIM of this T2AMPKAR FRET biosensor expressed in tumour spheroids using two-photon excitation.

  15. They shall wear fringes.

    Science.gov (United States)

    Sugar, M

    1999-01-01

    The multiple functions of clothes include utility, protection, rivalry, disguise, camouflage, display for seduction purposes, aggression, totemism, and status. Here the focus is on a decorative and distinctive hierarchical aspect of ancient dress, the tsitsit or fringes, whose original function is long absent, but that has endured for 3,500 years in Judaism. The beginning of their use beyond the totemic appears related to issues of changing identity from slavery to liberty, endowing noble status, exhibitionism, a symbol of identity, identification with the aggressor, a talisman, and potency. It is conceptualized that they became a symbol, or a specifier, that helped promote group cohesion in ex-slaves who were frightened, dependent, anxious, and not hopeful about their future. The tsitsit aided the development of a new identity and made all Israelites equal and noble to the observer. The durability of this symbol to the present is evident in its daily wear, as an accompaniment to daily prayers, as well as in its use as a burial shroud for males. It appears that the tsitsit have additional multiple functions. These are the promise of oral and genital satisfaction, and the pleasure of the after-life, superego warnings and control of sexual impulses, protection, survival value, and affirmation. Since they offer sublimation with acceptable gratification of instincts, the tsitsit have become ritualized and endure.

  16. Wear resistance properties of austempered ductile iron

    Science.gov (United States)

    Lerner, Y. S.; Kingsbury, G. R.

    1998-02-01

    A detailed review of wear resistance properties of austempered ductile iron (ADI) was undertaken to examine the potential applications of this material for wear parts, as an alternative to steels, alloyed and white irons, bronzes, and other competitive materials. Two modes of wear were studied: adhesive (frictional) dry sliding and abrasive wear. In the rotating dry sliding tests, wear behavior of the base material (a stationary block) was considered in relationship to countersurface (steel shaft) wear. In this wear mode, the wear rate of ADI was only one-fourth that of pearlitic ductile iron (DI) grade 100-70-03; the wear rates of aluminum bronze and leaded-tin bronze, respectively, were 3.7 and 3.3 times greater than that of ADI. Only quenched DI with a fully martensitic matrix slightly outperformed ADI. No significant difference was observed in the wear of steel shafts running against ADI and quenched DI. The excellent wear performance of ADI and its countersurface, combined with their relatively low friction coefficient, indicate potential for dry sliding wear applications. In the abrasive wear mode, the wear rate of ADI was comparable to that of alloyed hardened AISI 4340 steel, and approximately one-half that of hardened medium-carbon AISI 1050 steel and of white and alloyed cast irons. The excellent wear resistance of ADI may be attributed to the strain-affected transformation of high-carbon austenite to martensite that takes place in the surface layer during the wear tests.

  17. Abrasive Wear Resistance of Tool Steels Evaluated by the Pin-on-Disc Testing

    Science.gov (United States)

    Bressan, José Divo; Schopf, Roberto Alexandre

    2011-05-01

    Present work examines tool steels abrasion wear resistance and the abrasion mechanisms which are one main contributor to failure of tooling in metal forming industry. Tooling used in cutting and metal forming processes without lubrication fails due to this type of wear. In the workshop and engineering practice, it is common to relate wear resistance as function of material hardness only. However, there are others parameters which influences wear such as: fracture toughness, type of crystalline structure and the occurrence of hard precipitate in the metallic matrix and also its nature. In the present investigation, the wear mechanisms acting in tool steels were analyzed and, by normalized tests, wear resistance performance of nine different types of tool steels were evaluated by pin-on-disc testing. Conventional tool steels commonly used in tooling such as AISI H13 and AISI A2 were compared in relation to tool steels fabricated by sintering process such as Crucible CPM 3V, CPM 9V and M4 steels. Friction and wear testing were carried out in a pin-on-disc automated equipment which pin was tool steel and the counter-face was a abrasive disc of silicon carbide. Normal load of 5 N, sliding velocity of 0.45 m/s, total sliding distance of 3000 m and room temperature were employed. The wear rate was calculated by the Archard's equation and from the plotted graphs of pin cumulated volume loss versus sliding distance. Specimens were appropriately heat treated by quenching and three tempering cycles. Percentage of alloying elements, metallographic analyses of microstructure and Vickers microhardness of specimens were performed, analyzed and correlated with wear rate. The work is concluded by the presentation of a rank of tool steel wear rate, comparing the different tool steel abrasion wear resistance: the best tool steel wear resistance evaluated was the Crucible CPM 9V steel.

  18. The fractal characterization of wear particles in relation to the wear status

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The topography and distribution of wear particles produced in the wear process containmuch information about the wear status. Fractal geometry is applied in this paper to describe thewear particle accumulation in order to characterize the wear status change. The sliding wear test isperformed on a pin-on-disc apparatus using steel disc and brass pin. The investigation resultsshow that wear particle accumulation presents a strong bi-fractal behavior. Also, the fractal dimen-sion varies in correspondence to the wear status change. A new fractal index characterizing thewear particle accumulation is put forward. The wear tests of brass pin demonstrate that the fractalindex is effective in describing the wear status change.

  19. Wear behaviour of Al 261

    Directory of Open Access Journals (Sweden)

    N. Mathan Kumar

    2016-03-01

    Full Text Available Al 2618 matrix material was mixed with the Silicon Nitride (Si3N4, Aluminium Nitride (AlN and Zirconium Boride (ZrB2 reinforced particles. AMC was synthesized successfully by the stir casting method with the various X-wt.% of reinforcements (X = 0,2,4,6,8. Tribological behaviour was studied in this composite with various temperature conditions. The working conditions were Temperature (°C, Load (N, Velocity (m/s and Sliding Distances (m. Before wear testing the mechanical behaviour has been analysed. EDAX was confirmed by the matrix material composition. The Al 2618 alloy and the reinforcement mixers were confirmed by the X-ray Diffraction analysis. Wear rate (mm3/m, Wear resistance (m/mm3, Specific Wear rate (m/Nm and Co-efficient of friction (μ were analysed with various conditions. The worn surfaces were analysed before and after wear testing by Scanning Electron Microscope (SEM. Influence of process parameters and Percentage of contribution were analysed by Taguchi and Analysis of Variance (ANOVA methods. Genetic Algorithm (GA was adopted for optimizing the best and mean of the wear rate and to identify the exact influence of input parameters.

  20. Engineering Dark Chromoprotein Reporters for Photoacoustic Microscopy and FRET Imaging

    Science.gov (United States)

    Li, Yan; Forbrich, Alex; Wu, Jiahui; Shao, Peng; Campbell, Robert E.; Zemp, Roger

    2016-03-01

    A subset of the family of fluorescent proteins are the non-fluorescent chromoproteins which are promising probe molecules for use in photoacoustic imaging and as acceptor chromophores in Förster resonance energy transfer (FRET)-based biosensors. Typical approaches for fluorescent protein optimization by screening of large libraries of variants cannot be effectively applied to chromoproteins due to their characteristic lack of fluorescence. To address this challenge, we have developed a directed evolution method to iteratively screen large libraries of protein variants on the basis of their photoacoustic signal levels. By applying this procedure to the promising Ultramarine and cjBlue chromoprotein templates, we were able to identify improved variants with a 02-04 fold increase in photoacoustic signal-to-noise ratio after only a few evolutionary steps. These improved variants enable more accurate spectral de-mixing and localization of protein-producing bacteria in vivo and serve as effective FRET acceptors for both fluorescence- and photoacoustic-based detection of protease activity.

  1. Crack path simulation for cylindrical contact under fretting conditions

    Directory of Open Access Journals (Sweden)

    R.A. Cardoso

    2016-02-01

    Full Text Available In this work different strategies to estimate crack path for cylindrical contacts under fretting conditions are carried out. The main goal is to propose and to evaluate methodologies not only to estimate the direction of crack initiation but also the subsequent propagation in its earlier stages, where the stress field is multiaxial, non-proportional and decays very fast due to the proximity with the contact interface. Such complex conditions pose a substantial challenge to the modelling of crack path. The numerical simulations are provided by a 2D Finite Element Analysis taking into account interactions between the crack faces. The results show that, under fretting conditions, models based on the critical plane method are not effective to estimate the crack initiation orientation, while models based on a so called “critical direction” applied along a critical distance provide better results. Regarding the subsequent crack propagation orientation, it was possible to see that stress intensity factor based models where one considers an infinitesimal virtual crack emerging from an original preexistent crack are powerful mechanisms of crack orientation estimation.

  2. Paths to Förster's resonance energy transfer (FRET) theory

    Science.gov (United States)

    Masters, B. R.

    2014-02-01

    Theodor Förster (1910-1974) developed a phenomenological theory of nonradiative resonance energy transfer which proved to be transformative in the fields of chemistry, biochemistry, and biology. This paper explores the experimental and the theoretical antecedents of Förster's theory of resonance energy transfer (FRET). Early studies of sensitized fluorescence, fluorescence depolarization, and photosynthesis demonstrated the phenomena of long-range energy transfer. At the same time physicists developed theoretical models which contained common physical mechanisms and parameters: oscillating dipoles as models for the atoms or molecules, dipole-dipole coupling for the interaction, and a distance R0 that is optimal for resonance energy transfer. Early theories predicted R0 that was too large as compared to experiments. Finally, in 1946 Förster developed a classical theory and in 1948 he developed a quantum mechanical theory; both theories predicted an inverse sixth power dependence of the rate of energy transfer and a R0 that agreed with experiments. This paper attempts to determine why Förster succeeded when the other theoreticians failed to develop the correct theory. The putative roles of interdisciplinary education and collaborative research are discussed. Furthermore, I explore the role of science journals and their specific audiences in the popularization of FRET to a broad interdisciplinary community.

  3. Structurally Integrated Coatings for Wear and Corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Beardsley, M. Brad; Sebright, Jason L.

    2008-11-18

    alloys in earthmoving and related machinery is expected to increase multiple folds in the next decade. A major technical hurdle associated with the implementation of titanium alloys for heavy machinery is that of overcoming poor wear resistance. Proof of concept of the technologies developed in this project has been demonstrated by both laboratory testing of coupons and field testing of selected components. Further development will be required in order to have fully validated materials and process for production introduction and several technical hurdles remain to be addressed particular for use of the arc lamp fusing technology. The current project has reduced the risk of failure and provided sufficient data to encourage further investment by industry.

  4. Assessment of Cold Welding Between Separable Contact Surfaces Due to Impact and Fretting under Vacuum

    Science.gov (United States)

    Merstallinger, A.; Sales, M.; Semerad, E.; Dunn, B. D.

    2009-11-01

    A common failure mode seen during the testing and operation of spacecraft is termed "cold welding". European laboratories refer to this as "adhesion", "sticking" or "stiction". This publication is intended to provide the space community with the most recent understanding of the phenomenon of "cold welding" in relation to spacecraft mechanisms with separable contact surfaces. It presents some basic theory and describes a test method and the required equipment. Cold welding between two contacting surfaces can occur under conditions of impact or fretting. These surfaces may be bare metals, or inorganically or organically coated metals and their alloys. Standard procedures for quantifying the propensity of material surface pairs to cold weld to each other are proposed. Of particular interest will be the contact data of different materials, which are presented in numerical form and as tables summarising contacts between materials that can be either recommended or considered unsuitable for use under vacuum. The data have been compiled in a database that can be accessed online.

  5. Multiscale Modeling of Wear Degradation in Cylinder Liners

    KAUST Repository

    Moraes, Alvaro

    2014-03-20

    Every mechanical system is naturally subjected to some kind of wear process that, at some point, will cause failure in the system if no monitoring or treatment process is applied. Since failures often lead to high economical costs, it is essential both to predict and to avoid them. To achieve this, a monitoring system of the wear level should be implemented to decrease the risk of failure. In this work, we take a first step into the development of a multiscale indirect inference methodology for state-dependent Markovian pure jump processes. This allows us to model the evolution of the wear level and to identify when the system reaches some critical level that triggers a maintenance response. Since the likelihood function of a discretely observed pure jump process does not have an expression that is simple enough for standard nonsampling optimization methods, we approximate this likelihood by expressions from upscaled models of the data. We use the Master Equation (ME) to assess the goodness-of-fit and to compute the distribution of the hitting time to the critical level.

  6. Gear wear monitoring by modulation signal bispectrum based on motor current signal analysis

    Science.gov (United States)

    Zhang, Ruiliang; Gu, Fengshou; Mansaf, Haram; Wang, Tie; Ball, Andrew D.

    2017-09-01

    Gears are important mechanical components for power transmissions. Tooth wear is one of the most common failure modes, which can present throughout a gear's lifetime. It is significant to accurately monitor gear wear progression in order to take timely predictive maintenances. Motor current signature analysis (MCSA) is an effective and non-intrusive approach which is able to monitor faults from both electrical and mechanical systems. However, little research has been reported in monitoring the gear wear and estimating its severity based on MCSA. This paper presents a novel gear wear monitoring method through a modulation signal bispectrum based motor current signal analysis (MSB-MCSA). For a steady gear transmission, it is inevitable to exist load and speed oscillations due to various errors including wears. These oscillations can induce small modulations in the current signals of the driving motor. MSB is particularly effective in characterising such small modulation signals. Based on these understandings, the monitoring process was implemented based on the current signals from a run-to-failure test of an industrial two stages helical gearbox under a moderate accelerated fatigue process. At the initial operation of the test, MSB analysis results showed that the peak values at the bifrequencies of gear rotations and the power supply can be effective monitoring features for identifying faulty gears and wear severity as they exhibit agreeable changes with gear loads. A monotonically increasing trend established by these features allows a clear indication of the gear wear progression. The dismantle inspection at 477 h of operation, made when one of the monitored features is about 123% higher than its baseline, has found that there are severe scuffing wear marks on a number of tooth surfaces on the driving gear, showing that the gear endures a gradual wear process during its long test operation. Therefore, it is affirmed that the MSB-MSCA approach proposed is reliable

  7. Fluorescence resonance energy transfer (FRET) in chemistry and biology: Non-Förster distance dependence of the FRET rate

    Indian Academy of Sciences (India)

    Sangeeta Saini; Harjinder Singh; Biman Bagchi

    2006-01-01

    Fluorescence resonance energy transfer (FRET) is a popular tool to study equilibrium and dynamical properties of polymers and biopolymers in condensed phases and is now widely used in conjunction with single molecule spectroscopy. In the data analysis, one usually employs the Förster expression which predicts (1/6) distance dependence of the energy transfer rate. However, critical analysis shows that this expression can be of rather limited validity in many cases. We demonstrate this by explicitly considering a donor-acceptor system, polyfluorene (PF6)-tetraphenylporphyrin (TPP), where the size of both donor and acceptor is comparable to the distance separating them. In such cases, one may expect much weaker distance (as 1/2 or even weaker) dependence. We have also considered the case of energy transfer from a dye to a nanoparticle. Here we find 1/4 distance dependence at large separations, completely different from Förster. We also discuss recent application of FRET to study polymer conformational dynamics.

  8. Partially reduced graphene oxide based FRET on fiber-optic interferometer for biochemical detection

    Science.gov (United States)

    Yao, B. C.; Wu, Y.; Yu, C. B.; He, J. R.; Rao, Y. J.; Gong, Y.; Fu, F.; Chen, Y. F.; Li, Y. R.

    2016-03-01

    Fluorescent resonance energy transfer (FRET) with naturally exceptional selectivity is a powerful technique and widely used in chemical and biomedical analysis. However, it is still challenging for conventional FRET to perform as a high sensitivity compact sensor. Here we propose a novel ‘FRET on Fiber’ concept, in which a partially reduced graphene oxide (prGO) film is deposited on a fiber-optic modal interferometer, acting as both the fluorescent quencher for the FRET and the sensitive cladding for optical phase measurement due to refractive index changes in biochemical detection. The target analytes induced fluorescence recovery with good selectivity and optical phase shift with high sensitivity are measured simultaneously. The functionalized prGO film coated on the fiber-optic interferometer shows high sensitivities for the detections of metal ion, dopamine and single-stranded DNA (ssDNA), with detection limits of 1.2 nM, 1.3 μM and 1 pM, respectively. Such a prGO based ‘FRET on fiber’ configuration, bridging the FRET and the fiber-optic sensing technology, may serve as a platform for the realization of series of integrated ‘FRET on Fiber’ sensors for on-line environmental, chemical, and biomedical detection, with excellent compactness, high sensitivity, good selectivity and fast response

  9. N-way FRET microscopy of multiple protein-protein interactions in live cells.

    Directory of Open Access Journals (Sweden)

    Adam D Hoppe

    Full Text Available Fluorescence Resonance Energy Transfer (FRET microscopy has emerged as a powerful tool to visualize nanoscale protein-protein interactions while capturing their microscale organization and millisecond dynamics. Recently, FRET microscopy was extended to imaging of multiple donor-acceptor pairs, thereby enabling visualization of multiple biochemical events within a single living cell. These methods require numerous equations that must be defined on a case-by-case basis. Here, we present a universal multispectral microscopy method (N-Way FRET to enable quantitative imaging for any number of interacting and non-interacting FRET pairs. This approach redefines linear unmixing to incorporate the excitation and emission couplings created by FRET, which cannot be accounted for in conventional linear unmixing. Experiments on a three-fluorophore system using blue, yellow and red fluorescent proteins validate the method in living cells. In addition, we propose a simple linear algebra scheme for error propagation from input data to estimate the uncertainty in the computed FRET images. We demonstrate the strength of this approach by monitoring the oligomerization of three FP-tagged HIV Gag proteins whose tight association in the viral capsid is readily observed. Replacement of one FP-Gag molecule with a lipid raft-targeted FP allowed direct observation of Gag oligomerization with no association between FP-Gag and raft-targeted FP. The N-Way FRET method provides a new toolbox for capturing multiple molecular processes with high spatial and temporal resolution in living cells.

  10. Simultaneous live cell imaging using dual FRET sensors with a single excitation light.

    Directory of Open Access Journals (Sweden)

    Yusuke Niino

    Full Text Available Fluorescence resonance energy transfer (FRET between fluorescent proteins is a powerful tool for visualization of signal transduction in living cells, and recently, some strategies for imaging of dual FRET pairs in a single cell have been reported. However, these necessitate alteration of excitation light between two different wavelengths to avoid the spectral overlap, resulting in sequential detection with a lag time. Thus, to follow fast signal dynamics or signal changes in highly motile cells, a single-excitation dual-FRET method should be required. Here we reported this by using four-color imaging with a single excitation light and subsequent linear unmixing to distinguish fluorescent proteins. We constructed new FRET sensors with Sapphire/RFP to combine with CFP/YFP, and accomplished simultaneous imaging of cAMP and cGMP in single cells. We confirmed that signal amplitude of our dual FRET measurement is comparable to of conventional single FRET measurement. Finally, we demonstrated to monitor both intracellular Ca(2+ and cAMP in highly motile cardiac myocytes. To cancel out artifacts caused by the movement of the cell, this method expands the applicability of the combined use of dual FRET sensors for cell samples with high motility.

  11. Gear Wear Process Monitoring Using a Sideband Estimator Based on Modulation Signal Bispectrum

    Directory of Open Access Journals (Sweden)

    Ruiliang Zhang

    2017-03-01

    Full Text Available As one of the most common gear failure modes, tooth wear can produce nonlinear modulation sidebands in the vibration frequency spectrum. However, limited research has been reported in monitoring the gear wear based on vibration due to the lack of tools which can effectively extract the small sidebands. In order to accurately monitor gear wear progression in a timely fashion, this paper presents a gear wear condition monitoring approach based on vibration signal analysis using the modulation signal bispectrum-based sideband estimator (MSB-SE method. The vibration signals are collected using a run-to-failure test of gearbox under an accelerated test process. MSB analysis was performed on the vibration signals to extract the sideband information. Using a combination of the peak value of MSB-SE and the coherence of MSB-SE, the overall information of gear transmission system can be obtained. Based on the amplitude of MSB-SE peaks, a dimensionless indicator is proposed to assess the effects of gear tooth wear. The results demonstrated that the proposed indicator can be used to accurately and reliably monitor gear tooth wear and evaluate the wear severity.

  12. Microstructure and wear resistance of electro-thermal explosion sprayed stellite coating used for remanufacturing

    Institute of Scientific and Technical Information of China (English)

    JIN Guo; XU Bin-shi; WANG Hai-dou; LI Qing-fen; WEI Shi-cheng

    2005-01-01

    Electro-thermal explosion directional spraying was used to prepare the stellite coating on substrate of the AISI 1045 steel. The morphologies of cross-section and worn scar, porosity, distribution of elements, microhardness and wear resistance of the coating were determined by means of SEM, EDAX, micro-hardness tester and sliding wear tester. Because of the compact construction, good bonding and high hardness, the coating is characterized by good wear resistance. The results show that the mainly failure mode of the stellite coating is microplowing.

  13. Wear and Degradation Modes in Selected Vehicle Tribosystems

    Directory of Open Access Journals (Sweden)

    G. Pantazopoulos

    2015-03-01

    Full Text Available The wear and degradation mechanisms of two principle vehicle tribosystems are presented to elucidate the main causes of their premature failure. The first case study concerns the malfunction of an automotive cast iron pressure plate operated in an automobile clutch system. The second is related to the unexpected failure of a stainless steel brake disk of a high performance motorcycle. Both components are designed to function under sliding friction conditions that lead to the severe wear of consumable non-metallic parts of the tribosystems: the clutch disk and the brake pad, respectively. However, in both cases it was the unexpected failure of the conjugate metallic parts that resulted in terminal system damage. The experimental approach to identify the root cause of failure involved both microstructure characterization, as well as observations of the metallic contact surfaces by means of optical and scanning electron microscopy, in conjunction with microhardness and surface topography measurements. For the case of the stainless steel brake disk in particular, Finite Element Analysis was employed to simulate the operating tribosystem, identify the site(s prone for crack initiation and validate the failure mechanisms hypotheses.

  14. Preparation of mononucleosomal templates for analysis of transcription with RNA polymerase using spFRET.

    Science.gov (United States)

    Kudryashova, Kseniya S; Chertkov, Oleg V; Nikitin, Dmitry V; Pestov, Nikolai A; Kulaeva, Olga I; Efremenko, Anastasija V; Solonin, Alexander S; Kirpichnikov, Mikhail P; Studitsky, Vasily M; Feofanov, Alexey V

    2015-01-01

    Single positioned nucleosomes have been extensively employed as simple model experimental systems for analysis of various intranuclear processes. Here we describe an experimental system containing positioned mononucleosomes allowing transcription by various RNA polymerases. Each DNA template contains a pair of fluorescent labels (Cy3 and Cy5) allowing measuring relative distances between the neighboring coils of nucleosomal DNA using Forster resonance energy transfer (FRET). The single-particle FRET (spFRET) approach for analysis of DNA uncoiling from the histone octamer during transcription through chromatin is described in detail.

  15. Single-Molecule FRET Reveals Hidden Complexity in a Protein Energy Landscape

    OpenAIRE

    Tsytlonok, Maksym; Ibrahim, Shehu M.; Rowling, Pamela J.E.; Xu, Wenshu; Ruedas-Rama, Maria J.; Orte, Angel; Klenerman, David; Itzhaki, Laura S.

    2015-01-01

    Summary Here, using single-molecule FRET, we reveal previously hidden conformations of the ankyrin-repeat domain of AnkyrinR, a giant adaptor molecule that anchors integral membrane proteins to the spectrin-actin cytoskeleton through simultaneous binding of multiple partner proteins. We show that the ankyrin repeats switch between high-FRET and low-FRET states, controlled by an unstructured “safety pin” or “staple” from the adjacent domain of AnkyrinR. Opening of the safety pin leads to unrav...

  16. Fretting Fatigue Improvement of Ti6Al4V by Coating and Shot Peening

    Institute of Scientific and Technical Information of China (English)

    Daoxin LIU; Xiaodong ZHU; Bin TANG; Jiawen HE

    2005-01-01

    Ion beam enhanced deposition (IBED) was employed to increase the fretting fatigue resistance of Ti6AI4V. CrN and TiN hard coatings were applied on the base material and shot peening was combined with the hard coatings to study the duplex effect on fretting fatigue resistance, The IBED coatings exhibited a good bonding strength. They did not spall off even after shot peening. However, an optimum composition of CrN showed better fretting fatigue resistance than that of TiN with the same processing parameters.

  17. The Effect of Elevated Temperature on the Fretting Fatigue Behavior of Nickel Alloy IN-100

    Science.gov (United States)

    2008-04-01

    Saladin S-N data points for plain fatigue 86 4.16 Comparison of Ownby and Saladin S-N data points for fretting fatigue 87 4.17 Comparison of Ownby...and Saladin S-N data for all tests 88 4.18 Plot comparing ΔQ vs Nf from Ownby, Saladin & Madhi data points 89 4.19 Plot from Kawagoishi et al. [21...in this study 93 4.3 Madhi fretting and plain fatigue testing data 94 4.4 Saladin fretting and plain fatigue testing data 94 4.5 Comparison of

  18. Lateral diffusion contributes to FRET from lanthanide-tagged membrane proteins.

    Science.gov (United States)

    Lan, Tien-Hung; Wu, Guangyu; Lambert, Nevin A

    2015-08-14

    Diffusion can enhance Förster resonance energy transfer (FRET) when donors or acceptors diffuse distances that are similar to the distances separating them during the donor's excited state lifetime. Lanthanide donors remain in the excited state for milliseconds, which makes them useful for time-resolved FRET applications but also allows time for diffusion to enhance energy transfer. Here we show that diffusion dramatically enhances FRET between membrane proteins labeled with lanthanide donors. This phenomenon complicates interpretation of experiments that use long-lived donors to infer association or proximity of mobile membrane proteins, but also offers a method of monitoring diffusion in membrane domains in real time in living cells.

  19. Comparative gravimetric wear analysis in mobile versus fixed-bearing posterior stabilized total knee prostheses.

    Science.gov (United States)

    Delport, Hendrik P; Sloten, Jos Vander; Bellemans, Johan

    2010-06-01

    Polyethylene (PE) wear is the limiting factor for the longevity of a conventional total knee arthroplasty (TKA). Excessive wear leads to loosening and eventual implant failure. The aim of our in vitro study was to investigate wear of a PE tibial insert on a rotating platform as compared to the same insert fixed to the tibial baseplate and articulating with a similar femoral component. All tests were performed at Endolab Laboratories, Rosenheim, Germany using a knee joint simulator following ISO 14243-1. Three specific configurations were tested and compared to a loaded soak control: (1) the rotating platform using machined polyethylene (PE), (2) fixed bearing using machined PE, (3) fixed bearing using compression-moulded PE. Calf serum with a high protein concentration of 30 g/l was chosen as test lubricant. PE wear was measured gravimetrically using the ISO 14243-2 protocol. The total wear rates found for all systems tested were low. The mean wear rate was 1.40 mg per million cycles for the moulded fixed bearing, 4.07 mg per million cycles for the machined fixed bearing type and 0.82 mg per million cycles for the machined rotating platform bearing type. We conclude that the TKA system we tested (Performance, Biomet, Warsaw, IND, USA) demonstrated very low gravimetric wear. The wear rate of the same implant in the fixed mode compared to the rotating platform mode was four times higher.

  20. The influence of malrotation and femoral component material on patellofemoral wear during gait.

    Science.gov (United States)

    Vanbiervliet, J; Bellemans, J; Verlinden, C; Luyckx, J P; Labey, L; Innocenti, B; Vandenneucker, H

    2011-10-01

    Complications involving the patellofemoral joint, caused by malrotation of the femoral component during total knee replacement, are an important cause of persistent pain and failure leading to revision surgery. The aim of this study was to determine and quantify the influence of femoral component malrotation on patellofemoral wear, and to determine whether or not there is a difference in the rate of wear of the patellar component when articulated against oxidised zirconium (OxZr) and cobalt-chrome (CoCr) components. An in vitro method was used to simulate patellar maltracking for both materials. Both rates of wear and changes in height on the patellar articular surface were measured. The mean rates of wear measured were very small compared to standard tibiofemoral wear rates. When data for each femoral component material were pooled, the mean rate of wear was 0.19 mm3/Mcycle (sd 0.21) for OxZr and 0.34 mm3/Mcycle (sd 0.335) for CoCr. The largest change in height on each patella varied from -0.05 mm to -0.33 mm over the different configurations. The results suggest that patellar maltracking due to an internally rotated femoral component leads to an increased mean patellar wear. Although not statistically significant, the mean wear production may be lower for OxZr than for CoCr components.

  1. Calculation of wear (f.i. wear modulus) in the plastic cup of a hip joint prosthesis

    NARCIS (Netherlands)

    Ligterink, D.J.

    1975-01-01

    The wear equation is applied to the wear process in a hip joint prosthesis and a wear modulus is defined. The sliding distance, wear modulus, wear volume, wear area, contact angle and the maximum normal stress were calculated and the theoretical calculations applied to test results. During the wear

  2. Nano-hardness, wear resistance and pseudoelasticity of hafnium implanted NiTi shape memory alloy.

    Science.gov (United States)

    Zhao, Tingting; Li, Yan; Liu, Yong; Zhao, Xinqing

    2012-09-01

    NiTi shape memory alloy was modified by Hf ion implantation to improve its wear resistance and surface integrity against deformation. The Auger electron spectroscopy and x-ray photoelectron spectroscopy results indicated that the oxide thickness of NiTi alloy was increased by the formation of TiO₂/HfO₂ nanofilm on the surface. The nano-hardness measured by nano-indentation was decreased even at the depth larger than the maximum reach of the implanted Hf ion. The lower coefficient of friction with much longer fretting time indicated the remarkable improvement of wear resistance of Hf implanted NiTi, especially for the sample with a moderate incident dose. The formation of TiO₂/HfO₂ nanofilm with larger thickness and decrease of the nano-hardness played important roles in the improvement of wear resistance. Moreover, Hf implanted NiTi exhibited larger pseudoelastic recovery strain and retained better surface integrity even after being strained to 10% as demonstrated by in situ scanning electron microscope observation. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  3. EFFECT OF TOOL WEAR ON MICROSTRUCTURE, MECHANICAL PROPERTIES AND ACOUSTIC EMISSION OF FRICTION STIR WELDED 6061 Al ALLOY

    Institute of Scientific and Technical Information of China (English)

    W.M. Zeng; H.L. Wu; J. Zhang

    2006-01-01

    Tool condition is one of the main concerns in friction stir welding (FSW), because the geometrical condition of the tool pin including size and shape is strongly connected to the microstructure and mechanical performance of the weld. Tool wear occurs during FSW, especially for welding metal matrix composites with large amounts of abrasive particles, and high melting point materials, which significantly expedite tool wear and deteriorate the mechanical performance of welds.Tools with different pin-wear levels are used to weld 6061 Al alloy, while acoustic emission (AE) sensing, metallographic sectioning, and tensile testing are employed to evaluate the weld quality in various tool wear conditions. Structural characterization shows that the tool wear interferes with the weld quality and accounts for the formation of voids in the nugget zone. Tensile test analysis of samples verifies that both the ultimate tensile strength and the yield strength are adversely affected by the formation of voids in the nugget due to the tool wear. The failure location during tensile test clearly depends on the state of the tool wear, which led to the analysis of the relationships between the structure of the nugget and tool wear. AE signatures recorded during welding reveal that the AE hits concentrate on the higher amplitudes with increasing tool wear. The results show that the AE sensing provides a potentially effective method for the on-line monitoring of tool wear.

  4. Wear evaluation of a cross-linked medical grade polyethylene by ultra thin layer activation compared to gravimetry

    Science.gov (United States)

    Stroosnijder, Marinus F.; Hoffmann, Michael; Sauvage, Thierry; Blondiaux, Gilbert; Vincent, Laetitia

    2005-01-01

    Most of today's artificial joints rely on an articulating couple consisting of a CoCrMo alloy and a medical grade polyethylene. The wear of the polyethylene component is the major cause for long-term failure of these prostheses since the wear debris leads to adverse biological reactions. The polyethylene wear is usually measured by gravimetric methods, which are limited due to a low sensitivity and accuracy. To demonstrate the reliability of ultra thin layer activation (UTLA) as an alternative technique, wear tests on a cross-linked ultra-high-molecular weight polyethylene (XLPE) sliding against CoCrMo were performed on a wear tester featuring multi-directional sliding motion. The amount of polyethylene wear was evaluated by both UTLA and gravimetry. The particular TLA method used in this work employed the implantation of 7Be radioactive recoils into the polyethylene surface by means of a light mass particle beam. The results indicate that apart from its relatively high sensitivity, UTLA also offers the possibility for on-line measurements of polyethylene wear. This makes it a viable and complementary technique in wear test studies for medical implant purposes especially for those involving wear resistant materials and for rapid wear screening.

  5. Erosive Wear and Wear Mechanism of in situ TiCp/Fe Composites

    Institute of Scientific and Technical Information of China (English)

    Zhaojing LIU; Zhiliang NING; Fengzhen LI; Xiurong YAO; Shanzhi REN

    2005-01-01

    The base structure of in situ TiCP/Fe composites fabricated under industrial condition was changed by different heat treatments. Erosive wear tests were carried out and the results were compared with that of wear-resistant white cast iron. The results suggest that the wear resistance of the in situ TiCp/Fe composite is higher than that of wear-resistant white cast iron under the sand erosive wear condition. The wear mechanism of the wear-resistant white cast iron was a cycle process that base surface was worn and carbides were exposed, then carbides was broken and wear pits appeared. While the wear mechanism of in situ TiCp/Fe composite was a cycle process that base surface was worn and TiC grains were exposed and dropped. The wear resistance of in situ TiCp/Fe composite was lower than that of wear-resistant white cast iron under the slurry erosive wear condition. Under such circumstance,the material was not only undergone erosive wear but also electrochemistry erosion due to the contact with water in the medium. The wear behaviours can be a combination of two kinds of wear and the sand erosive wear is worse than slurry erosive wear.

  6. Feasibility of using acoustic emission to determine in-process tool wear

    Energy Technology Data Exchange (ETDEWEB)

    Lazarus, L.J.

    1996-04-01

    Acoustic emission (AE) was evaluated for its ability to predict and recognize failure of cutting tools during machining processes when the cutting tool rotates and the workpiece is stationary. AE output was evaluated with a simple algorithm. AE was able to detect drill failure when the transducer was mounted on the workpiece holding fixture. Drill failure was recognized as size was reduced to 0.0003 in. diameter. The ability to predict failure was reduced with drill size, drill material elasticity, and tool coating. AE output for the turning process on a lathe was compared to turning tool insert wear. The turning tool must have sufficient wear to produce a detectable change in AE output to predict insert failure.

  7. Methodological considerations for global analysis of cellular FLIM/FRET measurements

    Science.gov (United States)

    Adbul Rahim, Nur Aida; Pelet, Serge; Kamm, Roger D.; So, Peter T. C.

    2012-02-01

    Global algorithms can improve the analysis of fluorescence energy transfer (FRET) measurement based on fluorescence lifetime microscopy. However, global analysis of FRET data is also susceptible to experimental artifacts. This work examines several common artifacts and suggests remedial experimental protocols. Specifically, we examined the accuracy of different methods for instrument response extraction and propose an adaptive method based on the mean lifetime of fluorescent proteins. We further examined the effects of image segmentation and a priori constraints on the accuracy of lifetime extraction. Methods to test the applicability of global analysis on cellular data are proposed and demonstrated. The accuracy of global fitting degrades with lower photon count. By systematically tracking the effect of the minimum photon count on lifetime and FRET prefactors when carrying out global analysis, we demonstrate a correction procedure to recover the correct FRET parameters, allowing us to obtain protein interaction information even in dim cellular regions with photon counts as low as 100 per decay curve.

  8. Nucleic Acid Base Analog FRET-Pair Facilitating Detailed Structural Measurements in Nucleic Acid Containing Systems

    DEFF Research Database (Denmark)

    Börjesson, Karl; Preus, Søren; El-Sagheer, Afaf

    2009-01-01

    distances covering up to more than one turn of the DNA duplex. Importantly, we show that the rigid stacking of the two base analogs, and consequently excellent control of their exact positions and orientations, results in a high control of the orientation factor and hence very distinct FRET changes...... as the number of bases separating tCO and tC(nitro) is varied. A set of DNA strands containing the FRET-pair at wisely chosen locations will, thus, make it possible to accurately distinguish distance- from orientation-changes using FRET. In combination with the good nucleobase analog properties, this points...... toward detailed studies of the inherent dynamics of nucleic acid structures. Moreover, the placement of FRET-pair chromophores inside the base stack will be a great advantage in studies where other (biomacro)molecules interact with the nucleic acid. Lastly, our study gives possibly the first truly solid...

  9. Single-molecule three-color FRET with both negligible spectral overlap and long observation time.

    Directory of Open Access Journals (Sweden)

    Sanghwa Lee

    Full Text Available Full understanding of complex biological interactions frequently requires multi-color detection capability in doing single-molecule fluorescence resonance energy transfer (FRET experiments. Existing single-molecule three-color FRET techniques, however, suffer from severe photobleaching of Alexa 488, or its alternative dyes, and have been limitedly used for kinetics studies. In this work, we developed a single-molecule three-color FRET technique based on the Cy3-Cy5-Cy7 dye trio, thus providing enhanced observation time and improved data quality. Because the absorption spectra of three fluorophores are well separated, real-time monitoring of three FRET efficiencies was possible by incorporating the alternating laser excitation (ALEX technique both in confocal microscopy and in total-internal-reflection fluorescence (TIRF microscopy.

  10. Innovative measuring system for wear-out indication of high power IGBT modules

    DEFF Research Database (Denmark)

    Nielsen, Rasmus Ørndrup; Due, Jens; Munk-Nielsen, Stig

    2011-01-01

    Power converter failures are a major issue in modern Wind turbines. One of the key elements of power converters for high power application is the IGBT modules. A test bench capable of performing an accelerated wear-out test through power cycling of IGBT modules has been made. In the test bench...... it is possible to stress the IGBT module in a real life working point, controlling the voltage, current and phase of the device under test. An analysis of failure mechanisms has been carried out, indicating that VCE can be used as an sign of wear out of the IGBT module. Therefore an innovative measuring system...

  11. Effects of Contact Load on the Fretting Fatigue Behavior of IN-100 at Elevated Temperature

    Science.gov (United States)

    2009-03-01

    experimental setup which did not accurately model the turbine engine environment. Kawagoishi et al. [23] studied the nickel-based alloy Inconel 718 ...In their study with Inconel 718 [48, 49], it was found that the beneficial glaze oxide had formed and did affect the fretting fatigue life. Their...Waterhouse [52] investigated the fretting fatigue behaviors of austenitic steel type 321 and nickel-based alloy Inconel 718 at elevated temperatures. He

  12. Quantitative thermoelastic measurement on a helicopter glass fibre component underneath a surface anti-fretting coating.

    Directory of Open Access Journals (Sweden)

    Costa A.

    2010-06-01

    Full Text Available Thermoelastic stress analysis (TSA has been applied to measure the first stress invariant on a composite helicopter component under load. The component comprised inner mono-directional glass fiber layers with an outer central plate in glass fiber cloth, covered by an anti-fretting surface coating. In order to obtain quantitative results, a previous calibration of the thermoelastic constant obtained on a composite sample with a similar anti-fretting coating has been necessary.

  13. EXPERIMENTAL INVESTIGTION OF THE FRETTING PHENOMENON-DEPENDENCE OF NUMBERS CYCLES

    Directory of Open Access Journals (Sweden)

    Ştefan GHIMISI

    2014-12-01

    Full Text Available The present paper argues that adhesion forces and elastic deformation in the contact zone may contribute significantly to the relative displacement during fretting of metals. A simultaneously applied tangential force and normal into contact appears a adhesion force. A tangential force whose magnitude is less equal on greater than the force of limiting friction will not give rise on give rise to a sliding motion.It is determined the energy loss dissipated per fretting cycle.

  14. Failure Mechanism of Reflow Conductor Roll of Electroplating Tinning Line

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    The surface roughness of reflow conductor roll was checked on membrane sample. The surface morphology of conductor roll was observed by microscope, and the composition of adhered layer on conductor roll surface was analyzed by X-ray spectroscope. The results show that tin adhesion is the main reason for failure of conductor roll, and the failure of conductor roll is accelerated by wear. The measures to decrease tin adhesion and improve wear resistance were put forward.

  15. Should School Nurses Wear Uniforms?

    Science.gov (United States)

    Journal of School Health, 2001

    2001-01-01

    This 1958 paper questions whether school nurses should wear uniforms (specifically, white uniforms). It concludes that white uniforms are often associated with the treatment of ill people, and since many people have a fear reaction to them, they are not necessary and are even undesirable. Since school nurses are school staff members, they should…

  16. Tooth wear patterns in the deciduous dentition.

    Science.gov (United States)

    Warren, John J; Yonezu, Takuro; Bishara, Samir E

    2002-12-01

    Tooth wear is common in the deciduous dentition. A recent study suggests that tooth wear in the deciduous dentition is related to subsequent tooth wear in adults, so that early identification of factors related to tooth wear could be of long-term benefit. The purposes of this study were to describe patterns of tooth wear in the deciduous dentition and to relate tooth wear to occlusal characteristics and longitudinal dietary patterns. Data were collected as part of a longitudinal study of a cohort of children recruited at birth from Iowa hospitals. Stone casts were obtained in the deciduous dentition stage, and 355 children, 4 to 5 years old, met the selection criteria. Tooth wear was categorized for each tooth as none, mild, moderate, or severe, and related to occlusal characteristics and longitudinal data on fruit juice and soft drink consumption. All children exhibited some tooth wear on at least 1 tooth, and nearly 16% of them had at least 1 tooth with severe wear. Tooth wear was generally more severe in the maxillary arch and the anterior teeth. Severe tooth wear on the molars was significantly related to posterior crossbites, but severe tooth wear on the incisors was related to Class III canine relationships. There were no statistically significant relationships between tooth wear and soft drink or fruit juice consumption. Based on our results, we concluded that mild tooth wear is universal in the deciduous dentition, but only a few occlusal factors are related to severe tooth wear. Tooth wear was not related to any dietary patterns we investigated.

  17. Flow Cytometry Enables Multiplexed Measurements of Genetically Encoded Intramolecular FRET Sensors Suitable for Screening.

    Science.gov (United States)

    Doucette, Jaimee; Zhao, Ziyan; Geyer, Rory J; Barra, Melanie M; Balunas, Marcy J; Zweifach, Adam

    2016-07-01

    Genetically encoded sensors based on intramolecular FRET between CFP and YFP are used extensively in cell biology research. Flow cytometry has been shown to offer a means to measure CFP-YFP FRET; we suspected it would provide a unique way to conduct multiplexed measurements from cells expressing different FRET sensors, which is difficult to do with microscopy, and that this could be used for screening. We confirmed that flow cytometry accurately measures FRET signals using cells transiently transfected with an ERK activity reporter, comparing responses measured with imaging and cytometry. We created polyclonal long-term transfectant lines, each expressing a different intramolecular FRET sensor, and devised a way to bar-code four distinct populations of cells. We demonstrated the feasibility of multiplexed measurements and determined that robust multiplexed measurements can be conducted in plate format. To validate the suitability of the method for screening, we measured responses from a plate of bacterial extracts that in unrelated experiments we had determined contained the protein kinase C (PKC)-activating compound teleocidin A-1. The multiplexed assay correctly identifying the teleocidin A-1-containing well. We propose that multiplexed cytometric FRET measurements will be useful for analyzing cellular function and for screening compound collections.

  18. Ancestral Protein Reconstruction and Circular Permutation for Improving the Stability and Dynamic Range of FRET Sensors.

    Science.gov (United States)

    Clifton, Ben E; Whitfield, Jason H; Sanchez-Romero, Inmaculada; Herde, Michel K; Henneberger, Christian; Janovjak, Harald; Jackson, Colin J

    2017-01-01

    Small molecule biosensors based on Förster resonance energy transfer (FRET) enable small molecule signaling to be monitored with high spatial and temporal resolution in complex cellular environments. FRET sensors can be constructed by fusing a pair of fluorescent proteins to a suitable recognition domain, such as a member of the solute-binding protein (SBP) superfamily. However, naturally occurring SBPs may be unsuitable for incorporation into FRET sensors due to their low thermostability, which may preclude imaging under physiological conditions, or because the positions of their N- and C-termini may be suboptimal for fusion of fluorescent proteins, which may limit the dynamic range of the resulting sensors. Here, we show how these problems can be overcome using ancestral protein reconstruction and circular permutation. Ancestral protein reconstruction, used as a protein engineering strategy, leverages phylogenetic information to improve the thermostability of proteins, while circular permutation enables the termini of an SBP to be repositioned to maximize the dynamic range of the resulting FRET sensor. We also provide a protocol for cloning the engineered SBPs into FRET sensor constructs using Golden Gate assembly and discuss considerations for in situ characterization of the FRET sensors.

  19. Non-conjugated small molecule FRET for differentiating monomers from higher molecular weight amyloid beta species.

    Directory of Open Access Journals (Sweden)

    Chongzhao Ran

    Full Text Available BACKGROUND: Systematic differentiation of amyloid (Aβ species could be important for diagnosis of Alzheimer's disease (AD. In spite of significant progress, controversies remain regarding which species are the primary contributors to the AD pathology, and which species could be used as the best biomarkers for its diagnosis. These controversies are partially caused by the lack of reliable methods to differentiate the complicated subtypes of Aβ species. Particularly, differentiation of Aβ monomers from toxic higher molecular weight species (HrMW would be beneficial for drug screening, diagnosis, and molecular mechanism studies. However, fast and cheap methods for these specific aims are still lacking. PRINCIPAL FINDINGS: We demonstrated the feasibility of a non-conjugated FRET (Förster resonance energy transfer technique that utilized amyloid beta (Aβ species as intrinsic platforms for the FRET pair assembly. Mixing two structurally similar curcumin derivatives that served as the small molecule FRET pair with Aβ40 aggregates resulted in a FRET signal, while no signal was detected when using Aβ40 monomer solution. Lastly, this FRET technique enabled us to quantify the concentrations of Aβ monomers and high molecular weight species in solution. SIGNIFICANCE: We believe that this FRET technique could potentially be used as a tool for screening for inhibitors of Aβ aggregation. We also suggest that this concept could be generalized to other misfolded proteins/peptides implicated in various pathologies including amyloid in diabetes, prion in bovine spongiform encephalopathy, tau protein in AD, and α-synuclein in Parkinson disease.

  20. Improvements of harrows wear resistance

    Directory of Open Access Journals (Sweden)

    Warouma Arifa

    2015-12-01

    Full Text Available Wear is the main reason for the loss of performance of the parts for agricultural machinery. It leads to the degradation of the soil working quality. This work aims to highlight the wear resistance of the harrows discs manufactured, consolidated and sharpened differently. The tests were conducted in the laboratory and the field of the Faculty of Exploitation and Repair of Agricultural Machinery of the State Technical University of Kirovograd (Ukraine in 2015. The technical equipment consists of devices for consolidation by electric discharge and for measurement the linear wear of discs, a harrow, a sand test bed, a tractor and discs made of different materials and technologies. Some parameterized were collected during the laboratory test each 5 ha and up to 20 ha of operation and in the fields each 30 ha until the time limit of exploitation. The Laboratory tests have shown that after twenty (20 ha of operation, the wear resistance of the experimental discs made of steel 65G and consolidated by electric discharge with simultaneous grinding (sharpening angle of 30° is 2.95 times higher than the discs in series made of steel 28MnB5. The field experiment gave the following results: According to agro technical requirements, the plowing depth limit of serial discs made of steel 28MnB5 was reached after an operating duration of 120 ha while for experimental discs made of steel 65G and consolidated by electric discharge with simultaneous grinding (sharpening angle of 30 degrees this duration is of 156 ha. The diameter wear limit of experimental discs was reached after an operating duration of 179 ha against 154 ha for the serial ones. Therefore, the new technology can be applied during the manufacture and / or the repair of the discs.

  1. Needs and challenges in precision wear measurement

    Energy Technology Data Exchange (ETDEWEB)

    Blau, P.J.

    1996-01-10

    Accurate, precise wear measurements are a key element in solving both current wear problems and in basic wear research. Applications range from assessing durability of micro-scale components to accurate screening of surface treatments and thin solid films. Need to distinguish small differences in wear tate presents formidable problems to those who are developing new materials and surface treatments. Methods for measuring wear in ASTM standard test methods are discussed. Errors in using alterate methods of wear measurement on the same test specimen are also described. Human judgemental factors are a concern in common methods for wear measurement, and an experiment involving measurement of a wear scar by ten different people is described. Precision in wear measurement is limited both by the capabilities of the measuring instruments and by the nonuniformity of the wear process. A method of measuring wear using nano-scale indentations is discussed. Current and future prospects for incorporating advanced, higher-precision wear measurement methods into standards are considered.

  2. Consideration of Wear Rates at High Velocities

    Science.gov (United States)

    2010-03-01

    tionally, the texts by Bayer [3; 4], Rabinowicz [30], and Stachowiak [32] thoroughly cover the topic of wear mechanisms. A summary of the material is...March 1976. 30. Rabinowicz , E. Friction and Wear of Metals. John Wiley & Sons, New York, 1995. 31. Saka, N., A. M. Eleiche, and N. P. Suh. “Wear of

  3. An Evaluation of High Velocity Wear

    Science.gov (United States)

    2007-03-01

    x10F~ -4 [18:18-19]. Authors such as Hutchings and Rabinowicz however, do not explicitly limit equation (12) to plastic wear. They suggest that...Surface Melting of Rotating Bands. Wear, Vol. 38, 235- 243 21. Rabinowicz , E. (1965). Friction and Wear of Materials (Second ed.). New York, NY

  4. Sliding wear resistance of iron aluminides

    Indian Academy of Sciences (India)

    Garima Sharma; M Sundararaman; N Prabhu; G L Goswami

    2003-04-01

    Room temperature dry sliding wear behaviour of iron aluminides containing 28% aluminium and various amounts of chromium has been investigated using pin on disk wear tester. The aluminides were heat treated to have ordered 3 structure. It was found that wear rate of the aluminides increased with the increase of applied normal load and sliding speed. Wear resistance of the aluminides increased with increase in chromium content. SEM observation of the worn surface showed that the microcutting and microploughing were the dominant sliding wear mechanisms.

  5. A high sensitivity wear debris sensor using ferrite cores for online oil condition monitoring

    Science.gov (United States)

    Zhu, Xiaoliang; Zhong, Chong; Zhe, Jiang

    2017-07-01

    Detecting wear debris and measuring the increasing number of wear debris in lubrication oil can indicate abnormal machine wear well ahead of machine failure, and thus are indispensable for online machine health monitoring. A portable wear debris sensor with ferrite cores for online monitoring is presented. The sensor detects wear debris by measuring the inductance change of two planar coils wound around a pair of ferrite cores that make the magnetic flux denser and more uniform in the sensing channel, thereby improving the sensitivity of the sensor. Static testing results showed this wear debris sensor is capable of detecting 11 µm and 50 µm ferrous debris in 1 mm and 7 mm diameter fluidic pipes, respectively; such a high sensitivity has not been achieved before. Furthermore, a synchronized sampling method was also applied to reduce the data size and realize real-time data processing. Dynamic testing results demonstrated that the sensor is capable of detecting wear debris in real time with a high throughput of 750 ml min-1 the measured debris concentration is in good agreement with the actual concentration.

  6. Finite element analysis of stress and wear characterization in total ankle replacements.

    Science.gov (United States)

    Jay Elliot, Bradley; Gundapaneni, Dinesh; Goswami, Tarun

    2014-06-01

    Total Ankle Arthroplasty is performed in order to reduce the pain and loss of ambulation in patients with various forms of arthritis and trauma. Although replacement devices fail by a number of mechanisms, wear in the polyethylene liner constitutes one of the dominating failure modes. This leads to instability and loosening of the implant. Mechanisms that contribute to wear in the liners are high contact and subsurface stresses that break down the material over time. Therefore, it is important to understand the gait that generates these stresses. Methods to characterize and decrease wear in Ohio Total Ankle Replacements (TARs) have been performed in this research. This research utilizes finite element analysis of Wright State University (WSU) patented TAR models. From the Finite element analysis (FEA) results, mathematical models of contact conditions and wear mechanics were developed. The maximum wear rate values obtained in the study (at 25.598MPa, 3.74mm(3)/year) and maximum surface Mises stress obtained with new optimization model (11.52MPa) seem to be comparable with the maximum wear values obtained in other similar studies. These models were used to determine the best methods for wear characterization and reduction. Furthermore, optimization models were developed based on geometry of the implants. These equations optimize geometry, thus congruency and anatomical simulations for total ankle implants.

  7. Wear prediction in a fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, E.J. [USDOE Morgantown Energy Technology Center, WV (United States); Rogers, W.A. [EG and G Washington Analytical Services Center, Inc., Morgantown, WV (United States)

    1993-06-01

    A procedure to model the wear of surfaces exposed to a fluidized bed is formulated. A stochastic methodology adapting the kinetic theory of gases to granular flows is used to develop an impact wear model. This uses a single-particle wear model to account for impact wear from all possible-particle collisions. An adaptation of a single-particle abrasion model to describe the effects of many abrading particles is used to account for abrasive wear. Parameters describing granular flow within the fluidized bed, necessary for evaluation of the wear expressions, are determined by numerical solution of the fluidized bed hydrodynamic equations. Additional parameters, describing the contact between fluidized particles and the wearing surface, are determined by optimization based on wear measurements. The modeling procedure was used to analyze several bubbling and turbulent fluidized bed experiments with single-tube and tube bundle configurations. Quantitative agreement between the measured and predicted wear rates was found, with some exceptions for local wear predictions. This work demonstrates a methodology for wear predictions in fluidized beds.

  8. Fluoridation and tooth wear in Irish adults.

    LENUS (Irish Health Repository)

    Burke, F M

    2010-10-01

    The aim of this study was to determine the prevalence of tooth wear in adults in Ireland and its relationship with water fluoridation. The National Survey of Adult Oral Health was conducted in 2000\\/2001. Tooth wear was determined using a partial mouth examination assessing the upper and lower anterior teeth. A total of 2456 subjects were examined. In this survey, increasing levels and severity of tooth wear were associated with ageing. Men were more affected by tooth wear and were more likely to be affected by severe tooth wear than women. It was found that age, and gender were significant predictors of tooth wear (P < 0.01). Overall, there was no significant relationship between fluoridation and tooth wear in this study.

  9. Wear of micro end mills

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    This paper addresses the important issue of wear on micro end mills considering relevant metrological tools for its characterization and quantification. Investigation of wear on micro end mills is particularly difficult and no data are available in the literature. Small worn volumes cause large...... deviations from the ideal micro tool shape, dramatically changing the cutting edge profile as well as rake and clearance angles. This critically affects the performance of the micro tool leading to increased cutting forces and micro tool deflections with detrimental effects on the accuracy of the machined...... part. For this investigation 200 microns end mills are considered. Visual inspection of the micro tools requires high magnification and depth of focus. 3D reconstruction based on scanning electron microscope (SEM) images and stereo-pair technique is foreseen as a possible method for quantification...

  10. Analysis of initial crack path in fretting fatigue

    Directory of Open Access Journals (Sweden)

    J. Vázquez

    2016-07-01

    Full Text Available The initial crack path is analysed in a fretting fatigue test with cylindrical contact, where there is a stress gradient and a multiaxial and non-proportional stress state. For this, a cylindrical pad is pressed, with a constant normal load, N, against a dog-bone type fatigue test specimen. Then, the test specimen is subjected to a cyclic axial stress, σ. Due to the cyclical axial stress, the assembly used and the friction between the contact pair, a tangential cyclic load Q is generated. In these tests, both components are made of Al7075-T651 alloy. The crack initiation path along the fracture surface is optically measured using a focus variation technique. The contact stress/strain fields obtained analytically, in junction with the Fatemi-Socie (FS and Smith-Watson- Topper (SWT multiaxial fatigue parameters, allow us to determine the controlling parameters of the crack initiation process observed in the tests and to estimate the crack path during the early stage of the crack growth.

  11. Hydraulic System Wear Debris Analysis.

    Science.gov (United States)

    1982-08-03

    drawn. Each one-=L sample was drawn with a clean plastic pipette of one-mL capacity. The samples were placed in clean Ferrogram preparation bottles ...and from cavities in a block which held linear seals into sampling bottles . Several photographs of this debris , which was deposited on Ferro- grams...silicon in the glass overshadowed the elements of the wear debris . To overcome this difficulty, the Ferrogram should be pre- pared on a carbon-filled

  12. Single color FRET based measurements of conformational changes of proteins resulting from translocation inside cells.

    Science.gov (United States)

    Gahl, Robert F; Tekle, Ephrem; Tjandra, Nico

    2014-03-15

    Translocation of proteins to different parts of the cell is necessary for many cellular mechanisms as a means for regulation and a variety of other functions. Identifying how these proteins undergo conformational changes or interact with various partners during these events is critical to understanding how these mechanisms are executed. A protocol is presented that identifies conformational changes in a protein that occur during translocation while overcoming challenges in extracting distance information in very different environments of a living cell. Only two samples are required to be prepared and are observed with one optical setup. Live-cell FRET imaging has been applied to identify conformational changes between two native cysteines in Bax, a member of the Bcl-2 family of proteins that regulates apoptosis. Bax exists in the cytosol and translocates to the mitochondria outer membrane upon apoptosis induction. The distance, r, between the two native cysteines in the cytosolic structure of Bax necessitates the use of a FRET donor-accepter pair with R0~r as the most sensitive probe for identifying structural changes at these positions. Alexa Fluor 546 and Dabcyl, a dark acceptor, were used as FRET pairs - resulting in single color intensity variations of Alexa-546 as a measure of FRET efficiency. An internal reference, conjugated to Bax, was employed to normalize changes in fluorescence intensity of Alexa Fluor 546 due to inherent inhomogeneities in the living cell. This correction allowed the true FRET effects to be measured with increased precision during translocation. Normalization of intensities to the internal reference identified a FRET efficiency of 0.45±0.14 in the cytosol and 0.11±0.20 in the mitochondria. The procedure for the conjugation of the internal reference and FRET probes as well as the data analysis is presented. Published by Elsevier Inc.

  13. Hybridization accompanying FRET event in labeled natural nucleoside-unnatural nucleoside containing chimeric DNA duplexes.

    Science.gov (United States)

    Bag, Subhendu Sekhar; Das, Suman K; Pradhan, Manoj Kumar; Jana, Subhashis

    2016-09-01

    Förster resonance energy transfer (FRET) is a highly efficient strategy in illuminating the structures, structural changes and dynamics of DNA, proteins and other biomolecules and thus is being widely utilized in studying such phenomena, in designing molecular/biomolecular probes for monitoring the hybridization event of two single stranded DNA to form duplex, in gene detection and in many other sensory applications in chemistry, biology and material sciences. Moreover, FRET can give information about the positional status of chromophores within the associated biomolecules with much more accuracy than other methods can yield. Toward this end, we want to report here the ability of fluorescent unnatural nucleoside, triazolylphenanthrene ((TPhen)BDo) to show FRET interaction upon hybridization with fluorescently labeled natural nucleosides, (Per)U or (OxoPy)U or (Per)U, forming two stable chimeric DNA duplexes. The pairing selectivity and the thermal duplex stability of the chimeric duplexes are higher than any of the duplexes with natural nucleoside formed. The hybridization results in a Förster resonance energy transfer (FRET) from donor triazolylphenanthrene of (TPhen)BDo to acceptor oxopyrene of (OxoPy)U and/or to perylene chromophore of (Per)U, respectively, in two chimeric DNA duplexes. Therefore, we have established the FRET process in two chimeric DNA duplexes wherein a fluorescently labeled natural nucleoside ((OxoPy)U or (Per)U) paired against an unnatural nucleoside ((TPhen)BDo) without sacrificing the duplex stability and B-DNA conformation. The hybridization accompanying FRET event in these classes of interacting fluorophores is new. Moreover, there is no report of such designed system of chimeric DNA duplex. Our observed phenomenon and the design can potentially be exploited in designing more of such efficient FRET pairs for useful application in the detection and analysis of biomolecular interactions and in material science application. Copyright

  14. APPL proteins FRET at the BAR: direct observation of APPL1 and APPL2 BAR domain-mediated interactions on cell membranes using FRET microscopy.

    Directory of Open Access Journals (Sweden)

    Heidi J Chial

    Full Text Available BACKGROUND: Human APPL1 and APPL2 are homologous RAB5 effectors whose binding partners include a diverse set of transmembrane receptors, signaling proteins, and phosphoinositides. APPL proteins associate dynamically with endosomal membranes and are proposed to function in endosome-mediated signaling pathways linking the cell surface to the cell nucleus. APPL proteins contain an N-terminal Bin/Amphiphysin/Rvs (BAR domain, a central pleckstrin homology (PH domain, and a C-terminal phosphotyrosine binding (PTB domain. Previous structural and biochemical studies have shown that the APPL BAR domains mediate homotypic and heterotypic APPL-APPL interactions and that the APPL1 BAR domain forms crescent-shaped dimers. Although previous studies have shown that APPL minimal BAR domains associate with curved cell membranes, direct interaction between APPL BAR domains on cell membranes in vivo has not been reported. METHODOLOGY: Herein, we used a laser-scanning confocal microscope equipped with a spectral detector to carry out fluorescence resonance energy transfer (FRET experiments with cyan fluorescent protein/yellow fluorescent protein (CFP/YFP FRET donor/acceptor pairs to examine interactions between APPL minimal BAR domains at the subcellular level. This comprehensive approach enabled us to evaluate FRET levels in a single cell using three methods: sensitized emission, standard acceptor photobleaching, and sequential acceptor photobleaching. We also analyzed emission spectra to address an outstanding controversy regarding the use of CFP donor/YFP acceptor pairs in FRET acceptor photobleaching experiments, based on reports that photobleaching of YFP converts it into a CFP-like species. CONCLUSIONS: All three methods consistently showed significant FRET between APPL minimal BAR domain FRET pairs, indicating that they interact directly in a homotypic (i.e., APPL1-APPL1 and APPL2-APPL2 and heterotypic (i.e., APPL1-APPL2 manner on curved cell membranes

  15. Wear characteristics of Wright State University total ankle -replacement under shear and torsion loads

    OpenAIRE

    Gundapaneni, Dinesh; Goswami, Tarun

    2014-01-01

    Introduction: Total ankle replacement (TAR) involves replacement of the damaged bone with prosthetic components and is usually performed in patients suffering with arthritis to relieve pain and maintain motion. There are several different factors that contribute to failure of TARs but aseptic loosening is the primary method of failure in total ankle replacements. Because of its superior mechanical properties UHMWPE is used as a liner material in TARs. Wear generated from the liner due to high...

  16. On the influence of strain rate sensitivity on wear in the Archard regime

    Energy Technology Data Exchange (ETDEWEB)

    Brechet, Y. (Domaine Univ. de Grenoble, Saint Martin d' Heres (France). Lab. de Thermodynamique et Physico-Chimie Metallurgique); Estrin, Y. (Univ. of Western Australia, Nedlands (Australia). Dept. of Mechanical and Materials Engineering)

    1994-06-01

    Relating wear characteristics of a metallic material to its mechanical properties (yield strength, strain hardening coefficient) and its microstructural features (size and volume fraction of inclusions) is a long-standing problem. The diversity of mechanisms which are involved during wear processes makes it practically impossible to have a general theory which would encompass all thinkable situations corresponding to various loads and various regimes of sliding. Different regimes and the conditions for their occurrence have been systematized in wear mechanism maps. In this communication the authors are going to restrict their consideration to plasticity dominated wear which is expected to occur in the low velocity range where surface heating is negligible. In this regime, the prevalent wear mechanism is the removal of slivers of metal by plastic failure due to shearing of contact asperities. The classic works by Rabinowicz have demonstrated clearly that solid friction is a rate dependent problem and that the velocity dependence of dynamic solid friction is nothing else than a consequence of the increase of static solid friction with time during which normal load was applied prior to the commencement of sliding. Creep under normal compression stress leads to flattening of the junctions causing their strength to increase with time. Like solid friction, wear appears to be a rate dependent phenomenon, and the strain rate sensitivity of the flow stress can be expected to be relevant for wear resistance. The strain rate sensitivity is known to play an important role in other damage related properties, such as ductility and fracture toughness. The authors felt that it would be of interest to evaluate the effect of strain rate sensitivity on the wear rate as part of an attempt to relate the wear properties to a bulk constitutive equation, and as a guideline for assessing the influence of alloying elements known to affect the strain rate sensitivity.

  17. The effect of lubricant selection on galling in a model wear test

    NARCIS (Netherlands)

    Heide, van der E.; Huis in 't Veld, A.J.; Schipper, D.J.

    2001-01-01

    Galling is a known failure mechanism in sheet metal forming (SMF) processes. As a result of this wear process, the amount of waste increases, the production process becomes hard to control and eventually expensive maintenance is required in order to continue production. Delaying or avoiding galling

  18. Pelvic mass secondary to polyethylene and titanium alloy wear debris resulting in recurrent deep vein thrombosis.

    Science.gov (United States)

    Shilt, J S; Rozencwaig, R; Wilson, M R

    1997-12-01

    External venous compression can be a cause of deep vein thrombosis (DVT). This is an unusual case of acetabular component failure and resultant polyethylene and titanium alloy wear debris that presented as a pelvic mass and resulted in iliac vein compression and subsequent DVT.

  19. Influence of loading and rotation speed on Friction and Wear properties of CuAlBi Alloy

    Institute of Scientific and Technical Information of China (English)

    Liu Rongchang; Dong Litao; Li Xingyuan; Chen Xiuhong

    2007-01-01

    The variation of the friction coefficient of the CuAlBi alloy at different connecting loading and friction speed were investigated by using MMU-5G sliding friction-wear tester, besides, the wear mass loss of the CuAlBi alloy was measured, and the influence of loading and rotation speed on friction and wear properties of CuAlBi alloy was also discussed. The results show that the friction coefficient increase then decrease with increase of connecting loading as well as decreases with increase of friction speed, and the wear loss mass increases with increase of connecting loading and friction speed. As a result, the wear failure form of CuAlBi alloy is mainly ploughing.

  20. Sensitive detection of p65 homodimers using red-shifted and fluorescent protein-based FRET couples.

    Directory of Open Access Journals (Sweden)

    Joachim Goedhart

    Full Text Available BACKGROUND: Fluorescence Resonance Energy Transfer (FRET between the green fluorescent protein (GFP variants CFP and YFP is widely used for the detection of protein-protein interactions. Nowadays, several monomeric red-shifted fluorescent proteins are available that potentially improve the efficiency of FRET. METHODOLOGY/PRINCIPAL FINDINGS: To allow side-by-side comparison of several fluorescent protein combinations for detection of FRET, yellow or orange fluorescent proteins were directly fused to red fluorescent proteins. FRET from yellow fluorescent proteins to red fluorescent proteins was detected by both FLIM and donor dequenching upon acceptor photobleaching, showing that mCherry and mStrawberry were more efficient acceptors than mRFP1. Circular permutated yellow fluorescent protein variants revealed that in the tandem constructs the orientation of the transition dipole moment influences the FRET efficiency. In addition, it was demonstrated that the orange fluorescent proteins mKO and mOrange are both suitable as donor for FRET studies. The most favorable orange-red FRET pair was mKO-mCherry, which was used to detect homodimerization of the NF-kappaB subunit p65 in single living cells, with a threefold higher lifetime contrast and a twofold higher FRET efficiency than for CFP-YFP. CONCLUSIONS/SIGNIFICANCE: The observed high FRET efficiency of red-shifted couples is in accordance with increased Förster radii of up to 64 A, being significantly higher than the Förster radius of the commonly used CFP-YFP pair. Thus, red-shifted FRET pairs are preferable for detecting protein-protein interactions by donor-based FRET methods in single living cells.

  1. A FRET Biosensor for ROCK Based on a Consensus Substrate Sequence Identified by KISS Technology.

    Science.gov (United States)

    Li, Chunjie; Imanishi, Ayako; Komatsu, Naoki; Terai, Kenta; Amano, Mutsuki; Kaibuchi, Kozo; Matsuda, Michiyuki

    2017-01-11

    Genetically-encoded biosensors based on Förster/fluorescence resonance energy transfer (FRET) are versatile tools for studying the spatio-temporal regulation of signaling molecules within not only the cells but also tissues. Perhaps the hardest task in the development of a FRET biosensor for protein kinases is to identify the kinase-specific substrate peptide to be used in the FRET biosensor. To solve this problem, we took advantage of kinase-interacting substrate screening (KISS) technology, which deduces a consensus substrate sequence for the protein kinase of interest. Here, we show that a consensus substrate sequence for ROCK identified by KISS yielded a FRET biosensor for ROCK, named Eevee-ROCK, with high sensitivity and specificity. By treating HeLa cells with inhibitors or siRNAs against ROCK, we show that a substantial part of the basal FRET signal of Eevee-ROCK was derived from the activities of ROCK1 and ROCK2. Eevee-ROCK readily detected ROCK activation by epidermal growth factor, lysophosphatidic acid, and serum. When cells stably-expressing Eevee-ROCK were time-lapse imaged for three days, ROCK activity was found to increase after the completion of cytokinesis, concomitant with the spreading of cells. Eevee-ROCK also revealed a gradual increase in ROCK activity during apoptosis. Thus, Eevee-ROCK, which was developed from a substrate sequence predicted by the KISS technology, will pave the way to a better understanding of the function of ROCK in a physiological context.

  2. Live cell monitoring of glycine betaine by FRET-based genetically encoded nanosensor.

    Science.gov (United States)

    Ahmad, Mohammad; Ameen, Seema; Siddiqi, Tariq Omar; Khan, Parvez; Ahmad, Altaf

    2016-12-15

    Glycine betaine (GB) is one of the key compatible solutes that accumulate in the cell at exceedingly high level under the conditions of high salinity. It plays a crucial role in the maintenance of osmolarity of the cell without affecting the physiological processes. Analysis of stress-induced physiological conditions in living cells, therefore, requires real-time monitoring of cellular GB level. Glycine Betaine Optical Sensor (GBOS), a genetically-encoded FRET-based nanosensor developed in this study, allows the real-time monitoring of GB levels inside living cells. This nanosensor has been developed by sandwiching GB binding protein (ProX) between the Förster resonance energy transfer (FRET) pair, the cyan fluorescent protein (CFP) and yellow fluorescent protein (YFP). Conformational change in ProX, which was used as sensory domain, reported the change in the level of this compatible solute in in vitro and in vivo conditions. Binding of the GB to the sensory domain fetches close to both the fluorescent moieties that result in the form of increased FRET ratio. So, any change in the concentration of GB is correlated with change in FRET ratio. This sensor also reported the GB cellular dynamics in real-time in Escherichia coli cells after the addition of its precursor, choline. The GBOS was also expressed in yeast and mammalian cells to monitor the intracellular GB. Therefore, the GBOS represents a unique FRET-based nanosensor which allows the non-invasive ratiometric analysis of the GB in living cells.

  3. pH sensitivity of FRET reporters based on cyan and yellow fluorescent proteins.

    Science.gov (United States)

    Betolngar, Dahdjim-Benoît; Erard, Marie; Pasquier, Hélène; Bousmah, Yasmina; Diop-Sy, Awa; Guiot, Elvire; Vincent, Pierre; Mérola, Fabienne

    2015-05-01

    It is generally acknowledged that the popular cyan and yellow fluorescent proteins carried by genetically encoded reporters suffer from strong pH sensitivities close to the physiological pH range. We studied the consequences of these pH responses on the intracellular signals of model Förster resonant energy transfer (FRET) tandems and FRET-based reporters of cAMP-dependent protein kinase activity (AKAR) expressed in the cytosol of living BHK cells, while changing the intracellular pH by means of the nigericin ionophore. Although the simultaneous pH sensitivities of the donor and the acceptor may mask each other in some cases, the magnitude of the perturbations can be very significant, as compared to the functional response of the AKAR biosensor. Replacing the CFP donor by the spectrally identical, but pH-insensitive Aquamarine variant (pK1/2 = 3.3) drastically modifies the biosensor pH response and gives access to the acid transition of the yellow acceptor. We developed a simple model of pH-dependent FRET and used it to describe the expected pH-induced changes in fluorescence lifetime and ratiometric signals. This model qualitatively accounts for most of the observations, but reveals a complex behavior of the cytosolic AKAR biosensor at acid pHs, associated to additional FRET contributions. This study underlines the major and complex impact of pH changes on the signal of FRET reporters in the living cell.

  4. Evaluating Quantum Dot Performance in Homogeneous FRET Immunoassays for Prostate Specific Antigen

    Directory of Open Access Journals (Sweden)

    Shashi Bhuckory

    2016-02-01

    Full Text Available The integration of semiconductor quantum dots (QDs into homogeneous Förster resonance energy transfer (FRET immunoassay kits for clinical diagnostics can provide significant advantages concerning multiplexing and sensitivity. Here we present a facile and functional QD-antibody conjugation method using three commercially available QDs with different photoluminescence (PL maxima (605 nm, 655 nm, and 705 nm. The QD-antibody conjugates were successfully applied for FRET immunoassays against prostate specific antigen (PSA in 50 µL serum samples using Lumi4-Tb (Tb antibody conjugates as FRET donors and time-gated PL detection on a KRYPTOR clinical plate reader. Förster distance and Tb donor background PL were directly related to the analytical sensitivity for PSA, ...which resulted in the lowest limits of detection for Tb-QD705 (2 ng/mL, followed by Tb-QD655 (4 ng/mL, and Tb-QD605 (23 ng/mL. Duplexed PSA detection using the Tb-QD655 and Tb-QD705 FRET-pairs demonstrated the multiplexing ability of our immunoassays. Our results show that FRET based on QD acceptors is suitable for multiplexed and sensitive biomarker detection in clinical diagnostics.

  5. Significant FRET between SWNT/DNA and rare earth ions: a signature of their spatial correlations.

    Science.gov (United States)

    Ignatova, Tetyana; Najafov, Hikmat; Ryasnyanskiy, Aleksandr; Biaggio, Ivan; Zheng, Ming; Rotkin, Slava V

    2011-07-26

    Significant acceleration of the photoluminescence (PL) decay rate was observed in water solutions of two rare earth ions (REIs), Tb and Eu. We propose that the time-resolved PL spectroscopy data are explained by a fluorescence resonance energy transfer (FRET) between the REIs. FRET was directly confirmed by detecting the induced PL of the energy acceptor, Eu ion, under the PL excitation of the donor ion, Tb, with FRET efficiency reaching 7% in the most saturated solution, where the distance between the unlike REIs is the shortest. Using this as a calibration experiment, a comparable FRET was measured in the mixed solution of REIs with single-wall nanotubes (SWNTs) wrapped with DNA. From the FRET efficiency of 10% and 7% for Tb and Eu, respectively, the characteristic distance between the REI and SWNT/DNA was obtained as 15.9 ± 1.3 Å, suggesting that the complexes are formed because of Coulomb attraction between the REI and the ionized phosphate groups of the DNA.

  6. Wear mechanism and wear prevention in coal-fueled diesel engines. Task 3, Traditional approaches to wear prevention

    Energy Technology Data Exchange (ETDEWEB)

    Schwalb, J.A.

    1991-06-01

    Contamination of the lube-oil with hard abrasive particles leads to a three-body abrasive wear mechanism that highly accelerates piston ring/cylinder liner wear in coal-fueled diesel engines. One approach to reducing that wear is to modify the size and orientation of surface asperities on the cylinder to enhance the formation of a hydrodynamic film, and to provide avenues of escape for particles that would otherwise be trapped in the wear zone. Another approach is to introduce additives into the contaminated lube-oil that further enhance hydrodynamic film formation, form chemical films on the wearing surfaces, or form films on the contaminant particles. This work focuses on defining the effects of cylinder liner surface finish, various configurations of slots in the cylinder liner surface, and various additives in the contaminated lube-oil on the wear process. Wear tests were initiated in a bench apparatus using coal-ash contaminated lube-oil to test the various wear configurations. The results of these tests indicate that the formation of a hydrodynamic film between the ring and cylinder specimens is enhanced by increasing surface roughness, and by orienting the surface asperities normal to the direction of ring travel but modifications to the cylinder liner surface did not greatly reduce the wear rate. Additives to the lubricant seemed to have a much more significant effect on wear, with a dispersant additive highly accelerating the wear, while a detergent additive was able to reduce the wear almost to the rate achieved where there was no contaminant.

  7. A new methodology for predictive tool wear

    Science.gov (United States)

    Kim, Won-Sik

    An empirical approach to tool wear, which requires a series of machining tests for each combination of insert and work material, has been a standard practice for industries since early part of the twentieth century. With many varieties of inserts and work materials available for machining, the empirical approach is too experiment-intensive that the demand for the development of a model-based approach is increasing. With a model-based approach, the developed wear equation can be extended without additional machining experiments. The main idea is that the temperatures on the primary wear areas are increasing such that the physical properties of the tool material degrade substantially and consequently tool wear increases. Dissolution and abrasion are identified to be the main mechanisms for tool wear. Flank wear is predominantly a phenomenon of abrasion as evident by the presence of a scoring mark on the flank surface. Based on this statement, it is reasonable to expect that the flank-wear rate would increase with the content of hard inclusions. However, experimental flank wear results did not necessary correspond to the content of cementite phase present in the steels. Hence, other phenomena are believed to significantly affect wear behavior under certain conditions. When the cutting temperature in the flank interface is subjected to high enough temperatures, pearlitic structure austenizes. During the formation of a new austenitic phase, the existing carbon is dissolved into the ferrite matrix, which will reduce the abrasive action. To verify the austenitic transformation, turning tests were conducted with plain carbon steels. The machined surface areas are imaged using X-ray diffraction the Scanning Electron Microscope (SEM) and the Transmission Electron Microscope (TEM). On the other hand, crater wear occurs as a result of dissolution wear and abrasive wear. To verify the wear mechanisms of crater wear, various coating inserts as well as uncoated inserts were

  8. Role of surface roughness on corrosion and fretting corrosion behaviour of commercially pure titanium in Ringer's solution for bio-implant application

    Science.gov (United States)

    Sivakumar, Bose; Pathak, Lokesh Chandra; Singh, Raghuvir

    2017-04-01

    Influence of roughness (ra) from 43 to 474 nm on corrosion and fretting corrosion of commercially pure titanium (CpTi) was studied in the Ringer's solution. The anodic polarization and electrochemical impedance spectroscopy (EIS) revealed the highest corrosion resistance of CpTi with ra 43 nm and correlated well with the surface energy (SE). The highest potential drop associated with the fretting corrosion is observed for CpTi with ra 43 nm followed by 474 nm; this is found to correspond with the worn out area. The fretting current density (ifretting) is several order higher than obtained during the potentiodynamic polarization (without fretting) study. Fretting corrosion manifested by the drop in electrochemical potential is simulated with high accuracy using fretting current density and an initial contact area. Fretting corrosion at an applied potential (+250 mV(SCE)) is produced much larger fretting corrosion current density than during the open circuit potential (OCP).

  9. Failure analysis of high performance ballistic fibers

    OpenAIRE

    Spatola, Jennifer S

    2015-01-01

    High performance fibers have a high tensile strength and modulus, good wear resistance, and a low density, making them ideal for applications in ballistic impact resistance, such as body armor. However, the observed ballistic performance of these fibers is much lower than the predicted values. Since the predictions assume only tensile stress failure, it is safe to assume that the stress state is affecting fiber performance. The purpose of this research was to determine if there are failure mo...

  10. Failure analysis of high performance ballistic fibers

    OpenAIRE

    Spatola, Jennifer S

    2015-01-01

    High performance fibers have a high tensile strength and modulus, good wear resistance, and a low density, making them ideal for applications in ballistic impact resistance, such as body armor. However, the observed ballistic performance of these fibers is much lower than the predicted values. Since the predictions assume only tensile stress failure, it is safe to assume that the stress state is affecting fiber performance. The purpose of this research was to determine if there are failure mo...

  11. Nanoscale adhesion, friction and wear of proteins on polystyrene.

    Science.gov (United States)

    Bhushan, Bharat; Utter, Jason

    2013-02-01

    Protein layers are routinely deployed on biomaterials and biological micro/nanoelectromechanical systems (bioMEMS/NEMS) as a functional layer allowing for specific molecular recognition, binding properties or to facilitate biocompatibility. In addition, uncoated biomaterial surfaces will have uncontrolled protein layers adsorbing to the surface within seconds of implantation, so a pre-defined protein layer will improve the host response. Implanted biomaterials also experience micromotion over time which may degrade any surface protein layers. Degradation of these protein layers may lead to system failure or an unwanted immune response. Therefore, it is important to characterize the interfacial properties of proteins on biomaterial surfaces. In this study, the nanoscale adhesion, friction and wear properties of proteins adsorbed to a spin coated polystyrene surface were measured using atomic force microscopy (AFM) in deionized (DI) water and phosphate buffered saline. Adhesion, friction and wear have been measured for bovine serum albumin (BSA), collagen, fibronectin and streptavidin (STA) in DI water and PBS as a function of protein concentration. These proteins were chosen due to their importance and widespread application in the biotechnology field. Adhesion and friction were also measured for BSA and STA at two different temperatures and different pH values to simulate a biological environment. Based on this study, adhesion, friction and wear mechanisms of the different proteins are discussed.

  12. Tool Wear Characteristics of Oil Palm Empty Fruit Bunch Particleboard

    Science.gov (United States)

    Ratnasingam, Jegatheswaran; Chew Tek, Tee; Farrokhpayam, Saied Reza

    A series of machining experiments on the Oil-Palm Empty Fruit Bunch (OPEFB) particleboard were carried out using a CNC router, to evaluate the tool wearing properties of the composite in comparison to the conventional wood-material particleboard. A single-fluted tungsten-carbide router bit (12 mm φ, 18 000 rpm), with a rake angle of 15° was used in this experiment, in which the depth of cut was 1.5 mm and feed speed was 4.5 m min-1. The router bit machined the edge of the board, moving along the full length before returning to repeat the cycle. The tool was examined for the extent of wear after complete failure had occurred. The result found that the wear pattern was similar in the oil-palm based particleboard and the wood-based particleboard, but the former was twice more abrasive compared to the latter. Microscopic examination of the cutter edge revealed greater incidence of micro-fracture when cutting the oil-palm based particleboard, indicating the presence of hard impurities in the composite. From an economic perspective, the tooling cost for machining oil-palm based particleboard is estimated to be twice of the cost for machining wood-based particleboard. This study shows that the machining properties of oil-palm based particleboard will be a primary concern, if the board is to find widespread application as a potential substitute for wood-based particleboard.

  13. Surface Wear Measurement Using Optical Correlation Technique

    Science.gov (United States)

    Acinger, Kresimir

    1983-12-01

    The coherent optical correlation technique was applied for measuring the surface wear of a tappet (part of car engine), worn by friction with the camshaft. It was found that maximum correlation intensity decays exponentially with the number of wear cycles (i.e. camshaft revolutions). Tappets of the same make have an identical rate of correlation decay. Tappets of different makes have different rates of correlation decay which are in agreement with observed long term wear.

  14. Branched DNA nanostructures efficiently stabilised and monitored by novel pyrene-perylene 2'-α-l-amino-LNA FRET pairs

    DEFF Research Database (Denmark)

    Astakhova, I Kira; Santhosh Kumar, T; Campbell, Meghan A;

    2013-01-01

    Novel pyrene-perylene α-l-LNA FRET pairs described herein effectively detect assembly of 2- and 3-way branched DNA nanostructures prepared by postsynthetic microwave-assisted CuAAC click chemistry. The fluorescent signalling of assembly by internally positioned FRET pairs is achieved with low to ...

  15. Phanta: a non-fluorescent photochromic acceptor for pcFRET.

    Directory of Open Access Journals (Sweden)

    Craig Don Paul

    Full Text Available We have developed an orange non-fluorescent photochromic protein (quantum yield, 0.003 we call Phanta that is useful as an acceptor in pcFRET applications. Phanta can be repeatedly inter-converted between the two absorbing states by alternate exposure to cyan and violet light. The absorption spectra of Phanta in one absorbing state shows excellent overlap with the emission spectra of a number of donor green fluorescent proteins including the commonly used EGFP. We show that the Phanta-EGFP FRET pair is suitable for monitoring the activation of caspase 3 in live cells using readily available instrumentation and a simple protocol that requires the acquisition of two donor emission images corresponding to Phanta in each of its photoswitched states. This the first report of a genetically encoded non-fluorescent acceptor for pcFRET.

  16. A method to quantify FRET stoichiometry with phasor plot analysis and acceptor lifetime ingrowth.

    Science.gov (United States)

    Chen, WeiYue; Avezov, Edward; Schlachter, Simon C; Gielen, Fabrice; Laine, Romain F; Harding, Heather P; Hollfelder, Florian; Ron, David; Kaminski, Clemens F

    2015-03-10

    FRET is widely used for the study of protein-protein interactions in biological samples. However, it is difficult to quantify both the FRET efficiency (E) and the affinity (Kd) of the molecular interaction from intermolecular FRET signals in samples of unknown stoichiometry. Here, we present a method for the simultaneous quantification of the complete set of interaction parameters, including fractions of bound donors and acceptors, local protein concentrations, and dissociation constants, in each image pixel. The method makes use of fluorescence lifetime information from both donor and acceptor molecules and takes advantage of the linear properties of the phasor plot approach. We demonstrate the capability of our method in vitro in a microfluidic device and also in cells, via the determination of the binding affinity between tagged versions of glutathione and glutathione S-transferase, and via the determination of competitor concentration. The potential of the method is explored with simulations.

  17. On the use of nonfluorescent dye labeled ligands in FRET-based receptor binding studies.

    Science.gov (United States)

    Tahtaoui, Chouaib; Guillier, Fabrice; Klotz, Philippe; Galzi, Jean-Luc; Hibert, Marcel; Ilien, Brigitte

    2005-12-01

    The efficiency of fluorescence resonance energy transfer (FRET) is dependent upon donor-acceptor proximity and spectral overlap, whether the acceptor partner is fluorescent or not. We report here on the design, synthesis, and characterization of two novel pirenzepine derivatives that were coupled to patent blue VF and pinacyanol dyes. These nonfluorescent compounds, when added to cells stably expressing enhanced green fluorescent protein (EGFP)-fused muscarinic M1 receptors, promote EGFP fluorescence extinction in a time-, concentration-, and atropine-dependent manner. They display nanomolar affinity for the muscarinic receptor, determined using either FRET or classical radioligand binding conditions. We provide evidence that these compounds behave as potent acceptors of energy from excited EGFP with quenching efficiencies comparable to those of analogous fluorescent bodipy or rhodamine red pirenzepine derivatives. The advantages they offer over fluorescent ligands are illustrated and discussed in terms of reliability, sensitivity, and wider applicability of FRET-based receptor binding assays.

  18. Wear of hard materials by hard particles

    Energy Technology Data Exchange (ETDEWEB)

    Hawk, Jeffrey A.

    2003-10-01

    Hard materials, such as WC-Co, boron carbide, titanium diboride and composite carbide made up of Mo2C and WC, have been tested in abrasion and erosion conditions. These hard materials showed negligible wear in abrasion against SiC particles and erosion using Al2O3 particles. The WC-Co materials have the highest wear rate of these hard materials and a very different material removal mechanism. Wear mechanisms for these materials were different for each material with the overall wear rate controlled by binder composition and content and material grain size.

  19. Quantitative FRET imaging of leptin receptor oligomerization kinetics in single cells.

    Science.gov (United States)

    Biener, Eva; Charlier, Madia; Ramanujan, V Krishnan; Daniel, Nathalie; Eisenberg, Avital; Bjørbaek, Christian; Herman, Brian; Gertler, Arieh; Djiane, Jean

    2005-12-01

    Leptin, an adipocyte-secreted hormone, signals through activation of its membrane-embedded receptor (LEPR). To study the leptin-induced events occurring in short (LEPRa) and long (LEPRb) LEPRs in the cell membrane, by FRET (fluorescence resonance energy transfer) methodology, the respective receptors, tagged at their C-terminal with CFP (cyan fluorescent protein) or YFP (yellow fluorescent protein), were prepared. The constructs encoding mLEPRa (mouse LEPRa)-YFP and mLEPRa-CFP, mLEPRb-YFP and mLEPRb-CFP were tested for biological activity in transiently transfected CHO cells (Chinese-hamster ovary cells) and HEK-293T cells (human embryonic kidney 293 T cells) for activation of STAT3 (signal transduction and activators of transcription 3)-mediated LUC (luciferase) activity and binding of radiolabelled leptin. All four constructs were biologically active and were as potent as their untagged counterparts. The localization pattern of the fused protein appeared to be confined almost entirely to the cell membrane. The leptin-dependent interaction between various types of receptors in fixed cells were studied by measuring FRET, using fluorescence lifetime imaging microscopy and acceptor photobleaching methods. Both methods yielded similar results, indicating that (1) leptin receptors expressed in the cell membrane exist mostly as preformed LEPRa/LEPRa or LEPRb/LEPRb homo-oligomers but not as LEPRb/LEPRa hetero-oligomers; (2) the appearance of transient leptin-induced FRET in cells transfected with LEPRb/LEPRb reflects both a conformational change that leads to closer interaction in the cytosolic part and a higher FRET signal, as well as de novo homo-oligomerization; (3) in LEPRa/LEPRa, exposure to leptin does not lead to any increase in FRET signalling as the proximity of CFP and YFP fluorophores in space already gives maximal FRET efficiency of the preoligomerized receptors.

  20. Experimental verification of the kinetic theory of FRET using optical microspectroscopy and obligate oligomers.

    Science.gov (United States)

    Patowary, Suparna; Pisterzi, Luca F; Biener, Gabriel; Holz, Jessica D; Oliver, Julie A; Wells, James W; Raicu, Valerică

    2015-04-07

    Förster resonance energy transfer (FRET) is a nonradiative process for the transfer of energy from an optically excited donor molecule (D) to an acceptor molecule (A) in the ground state. The underlying theory predicting the dependence of the FRET efficiency on the sixth power of the distance between D and A has stood the test of time. In contrast, a comprehensive kinetic-based theory developed recently for FRET efficiencies among multiple donors and acceptors in multimeric arrays has waited for further testing. That theory has been tested in the work described in this article using linked fluorescent proteins located in the cytoplasm and at the plasma membrane of living cells. The cytoplasmic constructs were fused combinations of Cerulean as donor (D), Venus as acceptor (A), and a photo-insensitive molecule (Amber) as a nonfluorescent (N) place holder: namely, NDAN, NDNA, and ADNN duplexes, and the fully fluorescent quadruplex ADAA. The membrane-bound constructs were fused combinations of GFP2 as donor (D) and eYFP as acceptor (A): namely, two fluorescent duplexes (i.e., DA and AD) and a fluorescent triplex (ADA). According to the theory, the FRET efficiency of a multiplex such as ADAA or ADA can be predicted from that of analogs containing a single acceptor (e.g., NDAN, NDNA, and ADNN, or DA and AD, respectively). Relatively small but statistically significant differences were observed between the measured and predicted FRET efficiencies of the two multiplexes. While elucidation of the cause of this mismatch could be a worthy endeavor, the discrepancy does not appear to question the theoretical underpinnings of a large family of FRET-based methods for determining the stoichiometry and quaternary structure of complexes of macromolecules in living cells.

  1. Wear behaviors of HVOF sprayed WC-12Co coatings by laser remelting under lubricated condition

    Science.gov (United States)

    Dejun, Kong; Tianyuan, Sheng

    2017-03-01

    A HVOF (high velocity oxygen fuel) sprayed WC-12Co coating was remelted with a CO2 laser. The surface-interface morphologies and phases were analyzed by means of SEM (scanning electron microscopy), and XRD (X-ray diffraction), respectively. The friction and wear behaviors of WC-12Co coating under the dry and lubricated conditions were investigated with a wear test. The morphologies and distributions of chemical elements on worn scar were analyzed with a SEM, and its configured EDS (energy diffusive spectrometer), respectively, and the effects of lubricated condition on COFs (coefficient of friction) and wear performance were also discussed. The results show that the adhesion between the coating and the substrate is stronger after laser remetling (LR), in which mechanical bonding, accompanying with metallurgical bonding, was found. At the load of 80 N, the average COF under the dry and lubricated friction conditions is 0.069, and 0.052, respectively, the latter lowers by 23.3% than the former, and the wear rate under the lubricated condition decreases by 302.3% than that under the dry condition. The wear mechanism under the dry and lubrication conditions is primarily composed of abrasive wear, cracking, and fatigue failure.

  2. An integrated ultrasonic-inductive pulse sensor for wear debris detection

    Science.gov (United States)

    Du, Li; Zhe, Jiang

    2013-02-01

    One approach to detect signs of potential machine failure is to detect wear debris in the lubrication oil of a rotating or reciprocating machine because the size and the concentration of wear debris particles in the oil show a direct relationship with the level of wear. In this article, a proof-of-principle integrated wear debris sensor consisting of an ultrasonic pulse sensor and an inductive pulse sensor for detecting wear debris in lubrication oil is presented. The ultrasonic pulse sensor detects all solid debris (metallic and non-metallic debris). A flow recess structure is utilized to ensure that all wear debris passes the acoustic focal region so that all debris can be accurately counted and sized. The inductive pulse sensor detects and counts all metallic debris (ferrous and non-ferrous) based on the inductive Coulter counting principle. By comparing the results from the two sensing components, the sensor is capable of differentiating and detecting non-metallic debris, ferrous metallic debris and non-ferrous metallic debris.

  3. The Effect of Time Variation on the Wear Sliding Behavior of Composites

    Directory of Open Access Journals (Sweden)

    Wafaa M. Salih

    2009-01-01

    Full Text Available Composites materials are widely used in all industries all over the world, replacing many other engineering materials. Reasons for such popularity are many, among such, are their physical and mechanical properties in addition to the simplicity of their manufacturing processes. Machine elements that are made of polymeric materials are usually exposed to different causes of failure such as wear. The time effect on the wear behaviour of some composite materials (polyester-commercially fiber reinforcement named (E-glass was studied. In this study four type of composite different in number of layers, it had (3-6-9-12 layers (Wear volume 0.48, 0.41, 0.71 and 0.78 respectively. All experiments were conducted under dry condition. Preliminary results show the wear volume increases for all examined composites, as the statically applied load increases. Fourth type has the highest wear resistance, then third type and lastly first type. The wear volume increases for all examined composites, varied of time increases.

  4. Wear Behaviour of Nanostructured Polymer-Based Safety Films on Soda-Lime Glass

    Directory of Open Access Journals (Sweden)

    C. N. Panagopoulos

    2016-07-01

    Full Text Available The wear behaviour of bare and polymer-coated soda-lime glass specimens sliding against 440C stainless steel counterfaces was investigated with the aid of a pin-on-disk apparatus. The selected polymeric coatings were commercially supplied safety films, which are nowadays extensively applied on glass in the automotive and construction industry. One of their main failures is the degradation of their properties due to wear. In this work, the frictional behaviour of these coatings on glass were evaluated and compared to those of bare soda-lime glass. Correlations have been also made between the worn surfaces and weight loss in order to investigate the effect of wear conditions (speed, load on the wear behaviour of these tribosystems. In addition, during the dry wear of soda-lime glass sliding against stainless steel counterfaces, the dominant wear mechanisms were found to be localized adhesion and abrasion, whereas, in the case of the multilayered polymeric coatings localized adhesion, deformation and tearing were observed.

  5. FRETBursts: An Open Source Toolkit for Analysis of Freely-Diffusing Single-Molecule FRET.

    Science.gov (United States)

    Ingargiola, Antonino; Lerner, Eitan; Chung, SangYoon; Weiss, Shimon; Michalet, Xavier

    2016-01-01

    Single-molecule Förster Resonance Energy Transfer (smFRET) allows probing intermolecular interactions and conformational changes in biomacromolecules, and represents an invaluable tool for studying cellular processes at the molecular scale. smFRET experiments can detect the distance between two fluorescent labels (donor and acceptor) in the 3-10 nm range. In the commonly employed confocal geometry, molecules are free to diffuse in solution. When a molecule traverses the excitation volume, it emits a burst of photons, which can be detected by single-photon avalanche diode (SPAD) detectors. The intensities of donor and acceptor fluorescence can then be related to the distance between the two fluorophores. While recent years have seen a growing number of contributions proposing improvements or new techniques in smFRET data analysis, rarely have those publications been accompanied by software implementation. In particular, despite the widespread application of smFRET, no complete software package for smFRET burst analysis is freely available to date. In this paper, we introduce FRETBursts, an open source software for analysis of freely-diffusing smFRET data. FRETBursts allows executing all the fundamental steps of smFRET bursts analysis using state-of-the-art as well as novel techniques, while providing an open, robust and well-documented implementation. Therefore, FRETBursts represents an ideal platform for comparison and development of new methods in burst analysis. We employ modern software engineering principles in order to minimize bugs and facilitate long-term maintainability. Furthermore, we place a strong focus on reproducibility by relying on Jupyter notebooks for FRETBursts execution. Notebooks are executable documents capturing all the steps of the analysis (including data files, input parameters, and results) and can be easily shared to replicate complete smFRET analyzes. Notebooks allow beginners to execute complex workflows and advanced users to

  6. Fretting fatigue behavior of high-strength steel monostrands under bending load

    DEFF Research Database (Denmark)

    Winkler, Jan; Georgakis, Christos T.; Fischer, Gregor

    2015-01-01

    In this paper, the fretting fatigue behavior of pretensioned high-strength steel monostrands is investigated. To measure the local deformations on the strands, a novel method based on the digital image correlation (DIC) technique was used to quantify the relative movement between individual wires...... along the length of the monostrand. Information about the monostrand bending stiffness and the extent of relative displacement between core and outer wires of a monostrand undergoing flexural deformations is provided. From the series of dynamic fatigue tests, a fretting fatigue spectrum is derived...

  7. Effect of Produced Fluid on the Wear Behavior of Grade D Sucker Rod and N80 Type Tubing

    Institute of Scientific and Technical Information of China (English)

    YanTingjun; WangKuisheng

    2005-01-01

    Inuestigated wear tests of grade D sucker rod and N80 tubing with a produced liquid are the effect of the water cut of produced,liquid on the wear rate and the wear coefficient of the friction pair. And presented here is a comparison of tribological performance of tubing/sucker rod with sprayed tubing/sucker rod and tubing/sprayed sucker rod. The results show that one of the main reasons for wear failure between the sucker rod and the tubing is a high water cut of the produced liquid. The wear rate increases greatly when the water cut ranges from 70% to 85%, and increases gradually when the water cut is less than 70% or more than 85%. The higher the water cut is, the greater the wear rate will be. SEM (scanning electron microscope) micrographs show that the worn surface of the tubing is smoother, with shallow grooves, when the water cut is 55%; when the water cut is 95%, there are broader and deeper grooves on the worn surface. The results also show that the wear rate of the sprayed wear-resistant coating of sucker rod/tubing is less than that of the unsprayed sucker rod/tubing.

  8. Effect of Microstructure on Impact Fatigue Resistance and Impact Wear Resistance of Medium Cr-Si Cast Iron

    Institute of Scientific and Technical Information of China (English)

    LI Wei

    2007-01-01

    A great amount of iron grinding balls in tube mills have been consumed. Under this impact abrasive wear working condition, the failure of wear resistant alloying white irons grinding balls is mainly caused by fatigue spalling. The impact wear resistance of martensitic high chromium cast iron (Cr of 15 %) is not high sometimes, but its cost is not low. Thus, medium Cr-Si wear resistant cast iron is recommended. The influence of the iron on impact fatigue resistance and impact wear resistance is pronounced. Ball-on-ball impact fatigue test and high stress impact wear test of the grinding balls have been carried out. The results show that the impact fatigue resistance (IFR) and impact wear resistance (IWR) of medium Cr-Si cast iron are superior to those of martensitic high chromium cast iron (Cr of 15%). The main reasons are that (1) the stress in medium Cr-Si cast iron is released in the as-cast state; (2)the matrix is fine pearlite with better toughness and plasticity; (3) the pearlite is more stable compared with a retained austenite under repeated impact load and less phase transformation can take place; (4) high silicon content improves the morphology of eutectic carbide; (5) there is no secondary carbide which results in less crack sources. All these factors are beneficial to improvement of impact fatigue spalling resistance. The eutectic carbide M7C3 is the main constituent to resist wear.

  9. Abrasive Wear Map of Polymer Tapes in Sand Dust Environment

    Institute of Scientific and Technical Information of China (English)

    WU Tong-hai; DIAO Dong-feng

    2006-01-01

    To make clear the wear conditions of ATM (Automatic Teller Machine) tribosystem when servicing in Chinese sand dust environment, abrasive wear of two kinds of polymer tapes specified for ATM, PI (Polyimide) and PEN (Polyethylene-2, 6-naphthalenedicarboxylate), was investigated in simulated sand dust environment with ATM tape-scraper tribosystem under various conditions of loads and sliding distances. The surface profiles of worn tape were measured with a surface profiler in order to calculating the wear cross-section areas and the wear volumes. The specific wear rates of polymer tapes were calculated under load conditions of 0.6, 1 and 1.5 N, and wear mechanisms were investigated with optical topography photos. As main results, the specific wear rates show stage variations in the wear process and the wear resistance of polymer tape shows good relationship with the mechanical deformation factors. In consideration of the service life, four wear models are generalized according to the magnitude of specific wear rates,which include no wear, mild wear, normal wear and severe wear model and the corresponding wear mechanisms for the four wear models are discussed with typical worn topographies. Based on the wear models and corresponding wear mechanisms, the abrasive wear maps of two polymer tapes servicing in sand dust environments are concluded for its industrial applications.

  10. Temperature rise and wear of sliding contact of alloy steels

    Science.gov (United States)

    Goswami, Arindam Roy; Sardar, Santanu; Karmakar, Santanu Kumar

    2016-07-01

    The tribo-failure of machine elements under relative sliding velocities is greatly affected by frictional heating and resultant contact temperature rise. Nevertheless, the tribo-failure of automotive components is a combined effect of mechanical, thermal and chemical phenomena. Over the decades, there have been developed a number of different mathematical models for predicting surface temperature rise at sliding contact under different geometries of asperity contacts and operating conditions. The experimental investigation is still relevant today to find out the surface temperature rise at sliding contact along with the outcomes of friction and wear under various operating conditions for real time applications. The present work aims at finding average surface temperature rise at different sliding velocities, normal loads with different surface roughness experimentally. It also involves to prepare two different rough surfaces of alloy steels and to study their influences in the process of generating contact temperature rise under a given operating conditions.

  11. Localization of protein-protein interactions among three fluorescent proteins in a single living cell: three-color FRET microscopy

    Science.gov (United States)

    Sun, Yuansheng; Booker, Cynthia F.; Day, Richard N.; Periasamy, Ammasi

    2009-02-01

    Förster resonance energy transfer (FRET) methodology has been used for over 30 years to localize protein-protein interactions in living specimens. The cloning and modification of various visible fluorescent proteins (FPs) has generated a variety of new probes that can be used as FRET pairs to investigate the protein associations in living cells. However, the spectral cross-talk between FRET donor and acceptor channels has been a major limitation to FRET microscopy. Many investigators have developed different ways to eliminate the bleedthrough signals in the FRET channel for one donor and one acceptor. We developed a novel FRET microscopy method for studying interactions among three chromophores: three-color FRET microscopy. We generated a genetic construct that directly links the three FPs - monomeric teal FP (mTFP), Venus and tandem dimer Tomato (tdTomato), and demonstrated the occurrence of mutually dependent energy transfers among the three FPs. When expressed in cells and excited with the 458 nm laser line, the mTFP-Venus-tdTomato fusion proteins yielded parallel (mTFP to Venus and mTFP to tdTomato) and sequential (mTFP to Venus and then to tdTomato) energy transfer signals. To quantify the FRET signals in the three-FP system in a single living cell, we developed an algorithm to remove all the spectral cross-talk components and also to separate different FRET signals at a same emission channel using the laser scanning spectral imaging and linear unmixing techniques on the Zeiss510 META system. Our results were confirmed with fluorescence lifetime measurements and using acceptor photobleaching FRET microscopy.

  12. Evaluation of ring surfaces with several coatings for friction,wear and scuffing life

    Institute of Scientific and Technical Information of China (English)

    Dae-Hyun CHO; Young-Ze LEE

    2009-01-01

    Friction and wear of the sliding components in an automobile cause an increase in both fuel consumption and emission. Many engine components involved with sliding contact are all susceptible to scuffing failure at some points during their operating period. Therefore, it is important to evaluate the effects of various surface coatings on the tribological characteristics of the piston ring and cylinder block surface of a diesel engine. Wear and scuffing tests were conducted using a friction and wear measurement of the piston ring and cylinder block in a low friction diesel engine. The frictional forces, wear amounts and cycles to scuffing in the boundary lubricated sliding condition were measured using the reciprocating wear tester. The tester used a piece of the cylinder block as the reciprocating specimen and a segment of the piston ring material as the fixed pin. Several coatings on the ring specimen were used, such as DLC, TiN, Cr-ceramic and TiAlN, in order to improve the tribological characteristics of the ring. The coefficients of friction were monitored during the tests, and the wear volumes of the piston ring surfaces with various coatings were compared. Test results show that the DLC coating exhibits better tribological properties than the other coatings. The graphite structure of this coating is responsible for the low friction and wear of the DLC film. The TiN and DLC coatings show better scuffing resistance than the other coatings. The TiN and Cr-ceramic coated rings show good wear resistance and high friction.

  13. Enamel wear opposing polished and aged zirconia.

    Science.gov (United States)

    Burgess, J O; Janyavula, S; Lawson, N C; Lucas, T J; Cakir, D

    2014-01-01

    Aging of dental zirconia roughens its surface through low temperature degradation. We hypothesized that age-related roughening of zirconia crowns may cause detrimental wear to the enamel of an opposing tooth. To test our hypothesis, we subjected artificially aged zirconia and reference specimens to simulated mastication in a wear device and measured the wear of an opposing enamel cusp. Additionally, the roughness of the pretest surfaces was measured. The zirconia specimens, artificially aged by autoclave, showed no significant increase in roughness compared to the nonaged specimens. Furthermore, no significant difference in material or opposing enamel wear between the aged and nonaged zirconia was seen. All zirconia specimens showed less material and opposing enamel wear than the enamel to enamel control or veneering porcelain specimens. Scanning electron micrographs showed relatively smooth surfaces of aged and nonaged zirconia following wear testing. The micrographs of the veneering ceramic showed sharp fractured edges and fragments of wear debris. Zirconia may be considered a wear-friendly material for restorations opposing enamel, even after simulated aging.

  14. Numerical prediction of car tire wear

    NARCIS (Netherlands)

    Lupker, H.A.; Cheli, F.; Braghin, F.; Gelosa, E.; Keckman, A.

    2004-01-01

    Due to their many economic and ecological implications, the possibility to predict tire wear is of major importance to tire manufacturers, fleet owners and governments. Based on these observations, in 2000, a three-year project named TROWS (Tire and Road Wear and Slip assessment was started. One of

  15. Concrete ice abrasion rig and wear measurements

    NARCIS (Netherlands)

    Shamsutdinova, G.; Rike, P.B.; Hendriks, M.A.N.; Jacobsen, S.

    2015-01-01

    The wear of concrete material due to ice movement is a challenge for offshore and coastal structures. Concrete surfaces exposed to moving ice are subjected to wear at various rates depending on concrete and ice properties. At NTNU, Department of Structural Engineering, concrete ice abrasion phenomen

  16. Wear and microstructure in fine ceramic coatings

    Energy Technology Data Exchange (ETDEWEB)

    Vijande-Diaz, R.; Belzunce, J.; Fernandez, E. (ETS de Ingenieros Industriales, Area de Ingeneria Mecanica, Gijon (Spain)); Rincon, A.; Perez, M.C. (Inst. de Fisica-Quimica ' Roco Solano' , CSIC, Madrid (Spain))

    1991-08-15

    This paper presents a study of the wear resistance of two ceramic, plasma sprayed coatings of Al{sub 2}O{sub 3} and Cr{sub 2}O{sub 3}. Tests were carried out using an LWF-1 standard machine, with lineal contact, under dry friction, abrasion and lubricant conditions. The purpose of the tests were to study how load and speed affect material wear. Results show the lower wear rate of the ceramic coating compared with the steel one, as well as how remarkably load affects wear. On the other hand, however, considering the speed ranges used, wear resistance does not depend significantly on speed. The paper proves that the wear process follows Czichos' law. At the same time, reformulation of Archard's equation allows us to quantify wear using easily measurable factors such as pressure, speed, hardness, and those factors typically featuring this type of coatings, e.g. porosity. Also, a micrographic study of the coatings carried out by means of a scanning electron microscope has evidenced three stages in the wear mechanism: (a) plastic deformation of particles; (b) crack nucleation and propagation; and (c) loosening of ceramic particles. (orig.).

  17. Contact lens wear is intrinsically inflammatory.

    Science.gov (United States)

    Efron, Nathan

    2017-01-01

    Eye-care practitioners typically associate ocular inflammation during contact lens wear with serious complications such as microbial keratitis; however, more subtle mechanisms may be at play. This paper tests the notion that contact lens wear is intrinsically inflammatory by exploring whether uncomplicated contact lens wear meets the classical, clinical definition of inflammation - rubor (redness), calor (heat), tumor (swelling), dolor (pain) and functio laesa (loss of function) - as well as the contemporary, sub-clinical definition of inflammation (cellular and biochemical reactions). It is demonstrated that all of these clinical and sub-clinical criteria are met with hydrogel lens wear and most are met with silicone hydrogel lens wear, indicating that uncomplicated contact lens wear is intrinsically inflammatory. Consideration of both traditional and contemporary thinking about the role of inflammation in the human body leads to the perhaps surprising conclusion that the chronic, low grade, sub-clinical inflammatory status of the anterior eye during contact lens wear, which may be termed 'para-inflammation', is a positive, protective phenomenon, whereby up-regulation of the immune system, in a non-damaging way, maintains the eye in a state of 'heightened alert', ready to ward off any extrinsic noxious challenge. Characterisation of this inflammatory status may lead to the development of lens engineering or pharmacological strategies to modulate contact lens-induced inflammation, so as to render lens wear more safe and comfortable. © 2016 Optometry Australia.

  18. Inhibition of erosive wear by fluoride varnish

    NARCIS (Netherlands)

    Vieira, A.; Jager, D. H. J.; Ruben, J. L.; Huysmans, M. C. D. N. J. M.

    2007-01-01

    It has been suggested that fluoride products with a protective mechanical component are advantageous in the prevention of erosive wear. The aim of this study was to evaluate in situ the effect of fluoride varnish (FV) in the prevention of wear due to erosion and combined erosion and toothbrush abras

  19. Concrete ice abrasion rig and wear measurements

    NARCIS (Netherlands)

    Shamsutdinova, G.; Rike, P.B.; Hendriks, M.A.N.; Jacobsen, S.

    2015-01-01

    The wear of concrete material due to ice movement is a challenge for offshore and coastal structures. Concrete surfaces exposed to moving ice are subjected to wear at various rates depending on concrete and ice properties. At NTNU, Department of Structural Engineering, concrete ice abrasion phenomen

  20. Inhibition of erosive wear by fluoride varnish

    NARCIS (Netherlands)

    Vieira, A.; Jager, D. H. J.; Ruben, J. L.; Huysmans, M. C. D. N. J. M.

    2007-01-01

    It has been suggested that fluoride products with a protective mechanical component are advantageous in the prevention of erosive wear. The aim of this study was to evaluate in situ the effect of fluoride varnish (FV) in the prevention of wear due to erosion and combined erosion and toothbrush

  1. Biologically Based Restorative Management of Tooth Wear

    Directory of Open Access Journals (Sweden)

    Martin G. D. Kelleher

    2012-01-01

    Full Text Available The prevalence and severity of tooth wear is increasing in industrialised nations. Yet, there is no high-level evidence to support or refute any therapeutic intervention. In the absence of such evidence, many currently prevailing management strategies for tooth wear may be failing in their duty of care to first and foremost improve the oral health of patients with this disease. This paper promotes biologically sound approaches to the management of tooth wear on the basis of current best evidence of the aetiology and clinical features of this disease. The relative risks and benefits of the varying approaches to managing tooth wear are discussed with reference to long-term follow-up studies. Using reference to ethical standards such as “The Daughter Test”, this paper presents case reports of patients with moderate-to-severe levels of tooth wear managed in line with these biologically sound principles.

  2. Wear simulation effects on overdenture stud attachments.

    Science.gov (United States)

    Rutkunas, Vygandas; Mizutani, Hiroshi; Takahashi, Hidekazu; Iwasaki, Naohiko

    2011-01-01

    The aim of this study was to evaluate wear effects on overdenture resilient attachments. Six commercially available attachments were investigated: ERA orange and white (EO and EW), Locator pink, white and blue (LRP, LRW and LRB) and OP anchor (OP). Five specimens were used for wear simulation while other two specimens served as controls. Fifteen thousands insertion-removal cycles were simulated. Dimensional changes and surface characteristics were evaluated using light microscopy and SEM, respectively. Sudden decrease of retentive force was characteristic for EO and EW attachments. Retentive force of Locator attachments fluctuated throughout the wear simulation period. Dimensional changes and surface wear was more expressed on plastic cores than on plastic rings of attachment males. Based on SEM analysis, some of the specimens obtained smoother surface after wear simulation. Mechanism of retention loss of resilient overdenture attachments can be only partially explained by dimensional changes and surface alterations.

  3. Modeling wear of cast Ti alloys.

    Science.gov (United States)

    Chan, Kwai S; Koike, Marie; Okabe, Toru

    2007-05-01

    The wear behavior of Ti-based alloys was analyzed by considering the elastic-plastic fracture of individual alloys in response to the relevant contact stress field. Using the contact stresses as the process driving force, wear was computed as the wear rate or volume loss as a function of hardness and tensile ductility for Ti-based cast alloys containing an alpha, alpha+beta or beta microstructure with or without the intermetallic precipitates. Model predictions indicated that wear of Ti alloys increases with increasing hardness but with decreasing fracture toughness or tensile ductility. The theoretical results are compared with experimental data to elucidate the roles of microstructure in wear and contrasted against those in grindability.

  4. Assessment of variations in wear test methodology.

    Science.gov (United States)

    Gouvêa, Cresus V D; Weig, Karin; Filho, Thales R M; Barros, Renata N

    2010-01-01

    The properties of composite resin for dental fillings were improved by development, but its weakness continues to be its wear strength. Several tests have been proposed to evaluate wear in composite resin materials. The aim of this study was to verify how polishing and the type of abrasive can influence the wear rate of composite resin. The test was carried out on two groups. In one group we employed an ormocer and a hybrid composite that was polished group the composite was polished with the same abrasive paper plus a 1 microm and 0.25 microm grit diamond paste. A three-body wear test was performed using the metal sphere of the wear test machine, the composite and an abrasive. A diamond paste and aluminum oxide dispersion were used as abrasive. Analysis of the results showed that there was no difference between polishing techniques, but revealed a difference between abrasives.

  5. Dynamic SEM wear studies of tungsten carbide cermets. [friction and wear experiments

    Science.gov (United States)

    Brainard, W. A.; Buckley, D. H.

    1975-01-01

    Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined, and etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the tungsten carbide (WC) and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation, and the wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation, and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.

  6. Heart Failure

    Science.gov (United States)

    ... heart failure due to systolic dysfunction. http://www.uptodate.com/home. Accessed Sept. 26, 2014. Colucci WS. ... patient with heart failure or cardiomyopathy. http://www.uptodate.com/home. Accessed Sept. 26, 2014. Colucci WS. ...

  7. Asphalt wear and pollution transport

    Energy Technology Data Exchange (ETDEWEB)

    Lindgren, Asa [Division of Traffic Engineering, Lulea University of Technology Lulea (Sweden)

    1996-09-06

    Studded tires cause extensive wear of road surfaces during winter producing small particles. Besides transporting different adsorbed pollutants these particles also discharge metal ions by their own natural content. The major part (95%) of the asphalt is composed of stone fractions. The rest consists mainly of bitumen, which contains trace quantities of metals. Laboratory studies in this study have demonstrated different adsorbing properties of metal ions, as well as differences in adsorption when comparing stone materials. Two stone materials, a gabbro and a porphyry, have been tested for their adsorption properties concerning Pb, Cu, Zn and Cd. The gabbro showed better adsorption capacity than the porphyry. Gabbro has coarser grains, it is softer, and also has a higher content of most metals compared to the porphyry. In all tests lead and copper are more adsorbed than zinc and cadmium. All metal ions are released at about the same pH ({approx}4)

  8. Energetic aspects of boring tools wear

    Directory of Open Access Journals (Sweden)

    Lazarová Edita

    2002-03-01

    Full Text Available In the process of rock desintegration a boring tool is subjected to the wear. From a viewpoint of the bit wear, changes on the contact of operating tool with rock at its one-shot and rerun load or overload by external forces are technically significant. Theis change results in the degradation of bit working properties and the output of desintegration also decreases. In the major part of cases, together with the bit wear, the contact area of a tool with a rock massifs enhanced and this fact causes an increase of fines (dust creation during the desintegration. The wear is always connected with a friction, forces action, deformation, damage, and the increased mechanical work consumption. As to energetic aspects of bit wear, the wear was observed as a function of bore length and in the most of cases as a dependence of the operating time. A linear dependence between the wear intensity (bit wear per unit of bore length and the specific energy of desintegration (energy consumed per volume unit of desintegrated rock was experimentally verified. Thus, the changes of bit wear can be implicitly observed by monitoring the specific energy. At the same time, the specific energy is a function of input parameters of the desintegration process and in the field of applicable external forces it shows an extreme (minimum. Therefore, the specific energy is useful for the extreme optimisation of the rock desintegration process from the viewpoint of the bit wear. It was mathematically proven that the tool output at the desintegration exponentially decreases with the amount of work consumed in the rock desintegration. The derivation of this knowledge comes out from the Krendelev equation.

  9. Adhesive Wear of Rollers in Vacuum

    Science.gov (United States)

    Shaeef, Iqbal; Krantz, Timothy L.

    2012-01-01

    This work was done to support NASA's James Webb Space Telescope that is equipped with a Near Infrared Camera and Spectrograph and Micro Shutter Assembly (MSA). A MSA mechanism's qualification test in cryogenic vacuum at 30deg K for 96K cycles resulted in roller wear and formation of some debris. Lab tests in vacuum were conducted at NASA Glenn Research Center (GRC) to understand the wear of Ti6Al4V mated with 440F steel rollers. Misalignment angle was found to have the most significant effect on debris formation. At misalignment angle of 1.4deg, significant amount of wear debris were formed within 50,000 cycles. Very few wear particles were found for a zero misalignment angle, and the total wear was small even after 367,000 cycles. The mode of wear in all the tests was attributed to adhesion, which was clearly evident from video records as well as the plate-like amalgamated debris material from both rollers. The adhesive wear rate was found to be approximately proportional to the misalignment angle. The wear is a two-way phenomenon, and the mixing of both roller materials in wear debris was confirmed by x-ray fluorescence (XRF) and EDX spectra. While there was a net loss of mass from the steel rollers, XRF and energy dispersive x-ray (EDX) spectra showed peaks of Ti on steel rollers, and peaks of Fe on Ti rollers. These results are useful for designers in terms of maintaining appropriate tolerances to avoid misalignment of rolling elements and the resulting severe wear

  10. Time-gated FRET nanoassemblies for rapid and sensitive intra- and extracellular fluorescence imaging

    NARCIS (Netherlands)

    Afsari, Hamid Samareh; Cardoso Dos Santos, Marcelina; Lindén, Stina; Chen, Ting; Qiu, Xue; van Bergen En Henegouwen, Paul M P; Jennings, Travis L; Susumu, Kimihiro; Medintz, Igor L; Hildebrandt, Niko; Miller, Lawrence W

    2016-01-01

    Time-gated Förster resonance energy transfer (FRET) using the unique material combination of long-lifetime terbium complexes (Tb) and semiconductor quantum dots (QDs) provides many advantages for highly sensitive and multiplexed biosensing. Although time-gated detection can efficiently suppress samp

  11. Imaging real-time HIV-1 virion fusion with FRET-based biosensors

    Science.gov (United States)

    Jones, Daniel M.; Padilla-Parra, Sergi

    2015-01-01

    We have produced a novel, simple and rapid method utilising genetically encodable FRET-based biosensors to permit the detection of HIV-1 virion fusion in living cells. These biosensors show high sensitivity both spatially and temporally, and allow the real-time recovery of HIV-1 fusion kinetics in both single cells and cell populations simultaneously. PMID:26300212

  12. Optimization of ERK Activity Biosensors for both Ratiometric and Lifetime FRET Measurements

    Directory of Open Access Journals (Sweden)

    Pauline Vandame

    2014-01-01

    Full Text Available Among biosensors, genetically-encoded FRET-based biosensors are widely used to localize and measure enzymatic activities. Kinases activities are of particular interest as their spatiotemporal regulation has become crucial for the deep understanding of cell fate decisions. This is especially the case for ERK, whose activity is a key node in signal transduction pathways and can direct the cell into various processes. There is a constant need for better tools to analyze kinases in vivo, and to detect even the slightest variations of their activities. Here we report the optimization of the previous ERK activity reporters, EKAR and EKAREV. Those tools are constituted by two fluorophores adapted for FRET experiments, which are flanking a specific substrate of ERK, and a domain able to recognize and bind this substrate when phosphorylated. The latter phosphorylation allows a conformational change of the biosensor and thus a FRET signal. We improved those biosensors with modifications of: (i fluorophores and (ii linkers between substrate and binding domain, resulting in new versions that exhibit broader dynamic ranges upon EGF stimulation when FRET experiments are carried out by fluorescence lifetime and ratiometric measurements. Herein, we characterize those new biosensors and discuss their observed differences that depend on their fluorescence properties.

  13. Single-Molecule FRET Measurements in Additive-Enriched Aqueous Solutions.

    Science.gov (United States)

    Kempe, Daryan; Cerminara, Michele; Poblete, Simón; Schöne, Antonie; Gabba, Matteo; Fitter, Jörg

    2017-01-03

    The addition of high amounts of chemical denaturants, salts, viscosity enhancers or macro-molecular crowding agents has an impact on the physical properties of buffer solutions. Among others, the (microscopic) viscosity, the refractive index, the dielectric constant, and the ionic strength can be affected. Here, we systematically evaluate the importance of solvent characteristics with respect to single-molecule FRET (smFRET) data. First, we present a confocal based method for the determination of fluorescence quantum yields to facilitate a fast characterization of smFRET-samples at sub-nM-concentrations. As a case study, we analyze smFRET data of structurally rigid, double-stranded DNA-oligonucleotides in aqueous buffer and in buffers with specific amounts of glycerol, guanidine hydrochloride (GdnHCl), and sodium chloride (NaCl) added. We show that the calculation of interdye distances, without taking into account solvent-induced spectral and photophysical changes of the labels, leads to deviations of up to 4 Å from the real interdye distances. Additionally, we demonstrate that electrostatic dye-dye repulsions are negligible for the interdye distance regime considered here (>50 Å). Finally, we use our approach to validate the further compaction of the already unfolded state of phosphoglycerate kinase (PGK) with decreasing denaturant concentrations, a mechanism known as coil-globule transition.

  14. Dynamic imaging of glucose flux impedance using FRET sensors in wild-type Arabidopsis plants.

    Science.gov (United States)

    Chaudhuri, Bhavna; Hörmann, Friederike; Frommer, Wolf B

    2011-04-01

    Quantitative and dynamic analysis of metabolites and signalling molecules is limited by technical challenges in obtaining temporally resolved information at the cellular and compartmental level. Real-time information on signalling and metabolite levels with subcellular granularity can be obtained with the help of genetically encoded FRET (Förster resonance energy transfer) nanosensors. FRET nanosensors represent powerful tools for gene discovery, and analysis of regulatory networks, for example by screening mutants. However, RNA silencing has impaired our ability to express FRET nanosensors functionally in Arabidopsis plants. This drawback was overcome here by expressing the nanosensors in RNA silencing mutants. However, the use of silencing mutants requires the generation of homozygous lines deficient in RNA silencing as well as the mutation of interest and co-expression of the nanosensor. Here it is shown that dynamic changes in cytosolic glucose levels can readily be quantified in wild-type Arabidopsis plants at early stages of development (7-15 d) before silencing had a major effect on fluorescence intensity. A detailed protocol for screening 10-20 mutant seedlings per day is provided. The detailed imaging protocol provided here is suitable for analysing sugar flux in young wild-type plants as well as mutants affected in sugar signalling, metabolism, or transport using a wide spectrum of FRET nanosensors.

  15. Rise-time of FRET-acceptor fluorescence tracks protein folding

    NARCIS (Netherlands)

    Lindhoud, S.; Westphal, A.H.; Van Mierlo, C.P.M.; Visser, A.J.W.G.; Borst, J.W.

    2014-01-01

    Uniform labeling of proteins with fluorescent donor and acceptor dyes with an equimolar ratio is paramount for accurate determination of Förster resonance energy transfer (FRET) efficiencies. In practice, however, the labeled protein population contains donor-labeled molecules that have no correspon

  16. Tracing the conformational changes in BSA using FRET with environmentally-sensitive squaraine probes

    Science.gov (United States)

    Govor, Iryna V.; Tatarets, Anatoliy L.; Obukhova, Olena M.; Terpetschnig, Ewald A.; Gellerman, Gary; Patsenker, Leonid D.

    2016-06-01

    A new potential method of detecting the conformational changes in hydrophobic proteins such as bovine serum albumin (BSA) is introduced. The method is based on the change in the Förster resonance energy transfer (FRET) efficiency between protein-sensitive fluorescent probes. As compared to conventional FRET based methods, in this new approach the donor and acceptor dyes are not covalently linked to protein molecules. Performance of the new method is demonstrated using the protein-sensitive squaraine probes Square-634 (donor) and Square-685 (acceptor) to detect the urea-induced conformational changes of BSA. The FRET efficiency between these probes can be considered a more sensitive parameter to trace protein unfolding as compared to the changes in fluorescence intensity of each of these probes. Addition of urea followed by BSA unfolding causes a noticeable decrease in the emission intensities of these probes (factor of 5.6 for Square-634 and 3.0 for Square-685), and the FRET efficiency changes by a factor of up to 17. Compared to the conventional method the new approach therefore demonstrates to be a more sensitive way to detect the conformational changes in BSA.

  17. Metal ion induced FRET OFF-ON in tren/dansyl-appended rhodamine.

    Science.gov (United States)

    Lee, Min Hee; Kim, Hyun Jung; Yoon, Sangwoon; Park, Noejung; Kim, Jong Seung

    2008-01-17

    A series of new fluorescent probes bearing tren-spaced rhodamine B and dansyl groups have been synthesized. Compound 1 exhibits selective changes in the absorption and the emission spectra toward Cu2+ ion over miscellaneous metal cations. Among 1-3, 1 shows the best FRET efficiency through dansyl emission to rhodamine absorption for the Cu2+ ion.

  18. Spectral Unmixing Plate Reader: High-Throughput, High-Precision FRET Assays in Living Cells.

    Science.gov (United States)

    Schaaf, Tory M; Peterson, Kurt C; Grant, Benjamin D; Thomas, David D; Gillispie, Gregory D

    2017-03-01

    We have developed a microplate reader that records a complete high-quality fluorescence emission spectrum on a well-by-well basis under true high-throughput screening (HTS) conditions. The read time for an entire 384-well plate is less than 3 min. This instrument is particularly well suited for assays based on fluorescence resonance energy transfer (FRET). Intramolecular protein biosensors with genetically encoded green fluorescent protein (GFP) donor and red fluorescent protein (RFP) acceptor tags at positions sensitive to structural changes were stably expressed and studied in living HEK cells. Accurate quantitation of FRET was achieved by decomposing each observed spectrum into a linear combination of four component (basis) spectra (GFP emission, RFP emission, water Raman, and cell autofluorescence). Excitation and detection are both conducted from the top, allowing for thermoelectric control of the sample temperature from below. This spectral unmixing plate reader (SUPR) delivers an unprecedented combination of speed, precision, and accuracy for studying ensemble-averaged FRET in living cells. It complements our previously reported fluorescence lifetime plate reader, which offers the feature of resolving multiple FRET populations within the ensemble. The combination of these two direct waveform-recording technologies greatly enhances the precision and information content for HTS in drug discovery.

  19. An FITC-BODIPY FRET couple: application to selective, ratiometric detection and bioimaging of cysteine.

    Science.gov (United States)

    Ma, Dong Hee; Kim, Dokyoung; Akisawa, Takuya; Lee, Kyung-Ha; Kim, Kyong-Tai; Ahn, Kyo Han

    2015-04-01

    A novel FRET couple of fluorescein is disclosed, and it was readily constructed by conjugating an amino-BODIPY dye, a new FRET donor, with fluorescein isocyanate. Its potential was demonstrated by a fluorescence sensing system for cysteine, which was prepared by introducing acryloyl groups to the fluorescein moiety. The FRET probe exhibited promising ratiometric response to cysteine with high selectivity and sensitivity in a buffer solution containing acetonitrile at a physiological pH of 7.4, but showed slow reactivity. This slow response was solved by addition of a surfactant, thus allowing ratiometric imaging and determination of the endogenous level of cysteine in cells in HEPES buffer, by confocal fluorescence microscopy. Imaging experiments toward various cells suggested that such aryl acrylate type probes are vulnerable to the ubiquitous esterase activity. For the selected C6 cell line, in which the esterase activity was minimal, the ratiometric quantification of cysteine level was demonstrated. The FRET probe was also applied to determine the level of cysteine in human blood plasma.

  20. Reversible dimerization of Aequorea victoria fluorescent proteins increases the dynamic range of FRET-based indicators.

    Science.gov (United States)

    Kotera, Ippei; Iwasaki, Takuya; Imamura, Hiromi; Noji, Hiroyuki; Nagai, Takeharu

    2010-02-19

    Fluorescent protein (FP)-based Forster resonance energy transfer (FRET) technology is useful for development of functional indicators to visualize second messenger molecules and activation of signaling components in living cells. However, the design and construction of the functional indicators require careful optimization of their structure at the atomic level. Therefore, routine procedures for constructing FRET-based indicators currently include the adjustment of the linker length between the FPs and the sensor domain and relative dipole orientation of the FP chromophore. Here we report that, in addition to these techniques, optimization of the dimerization interface of Aequorea FPs is essential to achieve the highest possible dynamic range of signal change by FRET-based indicators. We performed spectroscopic analyses of various indicators (cameleon, TN-XL, and ATeam) and their variants. We chose variants containing mutant FPs with different dimerization properties, i.e., no, weak, or enhanced dimerization of the donor or acceptor FP. Our findings revealed that the FPs that dimerized weakly yielded high-performance FRET-based indicators with the greatest dynamic range.

  1. Structural Changes of Yellow Cameleon Domains Observed by Quantitative FRET Analysis and Polarized Fluorescence Correlation Spectroscopy

    NARCIS (Netherlands)

    Borst, J.W.; Laptenok, S.; Westphal, A.H.; Kühnemuth, R.; Hornen, H.; Visser, N.V.; Kalinin, S.; Aker, J.C.M.; Hoek, van A.; Seidel, C.A.M.; Visser, A.J.W.G.

    2008-01-01

    Förster resonance energy transfer (FRET) is a widely used method for monitoring interactions between or within biological macromolecules conjugated with suitable donor-acceptor pairs. Donor fluorescence lifetimes in absence and presence of acceptor molecules are often measured for the observation of

  2. Homo-FRET Imaging Enables Quantification of Protein Cluster Sizes with Subcellular Resolution

    NARCIS (Netherlands)

    Bader, A.N.; Hofman, E.G.; Voortman, J.; Henegouwen, P.; Gerritsen, H.C.

    2009-01-01

    Fluorescence-anisotropy-based homo-FRET detection methods can be employed to study clustering of identical proteins in cells. Here, the potential of fluorescence anisotropy microscopy for the quantitative imaging of protein clusters with subcellular resolution is investigated. Steady-state and

  3. Compound parabolic concentrator optical fiber tip for FRET-based fluorescent sensors

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren

    2015-01-01

    The Compound Parabolic Concentrator (CPC) optical fiber tip shape has been proposed for intensity based fluorescent sensors working on the principle of FRET (Förster Resonance Energy Transfer). A simple numerical Zemax model has been used to optimize the CPC tip geometry for a step-index multimod...

  4. Probing the Conformational Landscape of DNA Polymerases Using Diffusion-Based Single-Molecule FRET

    NARCIS (Netherlands)

    Hohlbein, J.; Kapanidis, A.N.

    2016-01-01

    Monitoring conformational changes in DNA polymerases using single-molecule Förster resonance energy transfer (smFRET) has provided new tools for studying fidelity-related mechanisms that promote the rejection of incorrect nucleotides before DNA synthesis. In addition to the previously known open

  5. FRET-based modified graphene quantum dots for direct trypsin quantification in urine

    Energy Technology Data Exchange (ETDEWEB)

    Poon, Chung-Yan; Li, Qinghua [Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong Special Administrative Region (Hong Kong); Zhang, Jiali; Li, Zhongping [Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong Special Administrative Region (Hong Kong); Research Center of Environmental Science and Engineering, School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006 (China); Dong, Chuan [Research Center of Environmental Science and Engineering, School of Chemistry and Chemical Engineering, Shanxi University, Taiyuan 030006 (China); Lee, Albert Wai-Ming; Chan, Wing-Hong [Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong Special Administrative Region (Hong Kong); Li, Hung-Wing, E-mail: hwli@hkbu.edu.hk [Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong Special Administrative Region (Hong Kong)

    2016-04-21

    A versatile nanoprobe was developed for trypsin quantification with fluorescence resonance energy transfer (FRET). Here, fluorescence graphene quantum dot is utilized as a donor while a well-designed coumarin derivative, CMR2, as an acceptor. Moreover, bovine serum albumin (BSA), as a protein model, is not only served as a linker for the FRET pair, but also a fluorescence enhancer of the quantum dots and CMR2. In the presence of trypsin, the FRET system would be destroyed when the BSA is digested by trypsin. Thus, the emission peak of the donor is regenerated and the ratio of emission peak of donor/emission peak of acceptor increased. By the ratiometric measurement of these two emission peaks, trypsin content could be determined. The detection limit of trypsin was found to be 0.7 μg/mL, which is 0.008-fold of the average trypsin level in acute pancreatitis patient's urine suggesting a high potential for fast and low cost clinical screening. - Highlights: • A FRET-based biosensor was developed for direct quantification of trypsin. • Fast and sensitive screening of pancreatic disease was facilitated. • The direct quantification of trypsin in urine samples was demonstrated.

  6. Corrosion and Fretting of a Modular Hip System: A Retrieval Analysis of 60 Rejuvenate Stems.

    Science.gov (United States)

    De Martino, Ivan; Assini, Joseph B; Elpers, Marcella E; Wright, Timothy M; Westrich, Geoffrey H

    2015-08-01

    Femoral stems with dual-taper modularity were introduced to allow independent control of length, offset, and version. Corrosion and fretting related to micromotion at the neck-stem junction are thought to stimulate an adverse local tissue reaction (ALTR). Analysis of 60 consecutively retrieved modular-neck stem implants (Rejuvenate, Stryker) revised primarily for ALTR was done to determine the variables influencing corrosion and fretting patterns at the neck-stem interface. Taper damage evaluation was performed with stereomicrocopic analysis with two observers. Evidence of fretting and corrosion was seen at the neck-stem taper in all implants, including three implants revised for periprosthetic fractures within four weeks of the index surgery indicating that this process starts early. Femoral stems paired with the long overall neck lengths had significantly higher corrosion scores. Correlation of the corrosion severity at particular locations with the length of implantation suggests that the neck-stem junction experiences cyclic cantilever bending in vivo. The positive correlation between the length of implantation and fretting/corrosion scores bodes poorly for patients who still have this implant. Scanning electron microscopy on a subset of specimens was also performed to evaluate the black corrosion material. We strongly urge frequent follow-up exams for every patient with this particular modular hip stem. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Correlative Förster Resonance Electron Transfer-Proximity Ligation Assay (FRET-PLA) Technique for Studying Interactions Involving Membrane Proteins.

    Science.gov (United States)

    Ivanusic, Daniel; Denner, Joachim; Bannert, Norbert

    2016-08-01

    This unit provides a guide and detailed protocol for studying membrane protein-protein interactions (PPI) using the acceptor-sensitized Förster resonance electron transfer (FRET) method in combination with the proximity ligation assay (PLA). The protocol in this unit is focused on the preparation of FRET-PLA samples and the detection of correlative FRET/PLA signals as well as on the analysis of FRET-PLA data and interpretation of correlative results when using cyan fluorescent protein (CFP) as a FRET donor and yellow fluorescent protein (YFP) as a FRET acceptor. The correlative application of FRET and PLA combines two powerful tools for monitoring PPI, yielding results that are more reliable than with either technique alone. © 2016 by John Wiley & Sons, Inc.

  8. Intracellular localization and interaction of mRNA binding proteins as detected by FRET

    Directory of Open Access Journals (Sweden)

    Port J

    2010-09-01

    Full Text Available Abstract Background A number of RNA binding proteins (BPs bind to A+U rich elements (AREs, commonly present within 3'UTRs of highly regulated RNAs. Individual RNA-BPs proteins can modulate RNA stability, RNA localization, and/or translational efficiency. Although biochemical studies have demonstrated selectivity of ARE-BPs for individual RNAs, less certain is the in vivo composition of RNA-BP multiprotein complexes and how their composition is affected by signaling events and intracellular localization. Using FRET, we previously demonstrated that two ARE-BPs, HuR and AUF1, form stable homomeric and heteromeric associations in the nucleus and cytoplasm. In the current study, we use immuno-FRET of endogenous proteins to examine the intracellular localization and interactions of HuR and AUF1 as well as KSRP, TIA-1, and Hedls. These results were compared to those obtained with their exogenously expressed, fluorescently labeled counterparts. Results All ARE-BPs examined were found to colocalize and to form stable associations with selected other RNA-BPs in one or more cellular locations variably including the nucleus, cytoplasm (in general, or in stress granules or P bodies. Interestingly, FRET based interaction of the translational suppressor, TIA-1, and the decapping protein, Hedls, was found to occur at the interface of stress granules and P bodies, dynamic sites of intracellular RNA storage and/or turnover. To explore the physical interactions of RNA-BPs with ARE containing RNAs, in vitro transcribed Cy3-labeled RNA was transfected into cells. Interestingly, Cy3-RNA was found to coalesce in P body like punctate structures and, by FRET, was found to interact with the RNA decapping proteins, Hedls and Dcp1. Conclusions Biochemical methodologies, such as co-immunoprecipitation, and cell biological approaches such as standard confocal microscopy are useful in demonstrating the possibility of proteins and/or proteins and RNAs interacting. However, as

  9. Wear Patterns and Wear Mechanisms of Tool in High Speed Cutting of Inconel 718%高速切削Inconel 718刀具磨损形态和机理分析

    Institute of Scientific and Technical Information of China (English)

    黄雪红; 赵军

    2013-01-01

    The dry-cutting tests of high speed turning Inconel 718 using coated carbide tool is presented.The worn surface morphology of tool and its abrasion mechanism are studied by scanning electronic microscope (SEM) and energy disperse spectrum (EDS).The results show that the failure modes are rake wear,flake wear,flaking and chipping and the main failure mechanisms of tool are adhesive wear,abrasion wear,oxidation wear,diffusive wear and so on.%利用涂层硬质合金刀具对Inconel 718进行了高速干切削试验,采用扫描电子显微镜SEM和能量分散光谱EDS扫描,对不同切削参数下刀具的损坏形态和损坏机理进行了研究.分析结果表明刀具损坏形式主要有前刀面磨损、后刀面磨损、剥落和崩刃.刀具损坏机理主要是粘结磨损、磨粒磨损、氧化磨损和扩散磨损等.

  10. Temporal Data Set Reduction Based on D-Optimality for Quantitative FLIM-FRET Imaging.

    Science.gov (United States)

    Omer, Travis; Intes, Xavier; Hahn, Juergen

    2015-01-01

    Fluorescence lifetime imaging (FLIM) when paired with Förster resonance energy transfer (FLIM-FRET) enables the monitoring of nanoscale interactions in living biological samples. FLIM-FRET model-based estimation methods allow the quantitative retrieval of parameters such as the quenched (interacting) and unquenched (non-interacting) fractional populations of the donor fluorophore and/or the distance of the interactions. The quantitative accuracy of such model-based approaches is dependent on multiple factors such as signal-to-noise ratio and number of temporal points acquired when sampling the fluorescence decays. For high-throughput or in vivo applications of FLIM-FRET, it is desirable to acquire a limited number of temporal points for fast acquisition times. Yet, it is critical to acquire temporal data sets with sufficient information content to allow for accurate FLIM-FRET parameter estimation. Herein, an optimal experimental design approach based upon sensitivity analysis is presented in order to identify the time points that provide the best quantitative estimates of the parameters for a determined number of temporal sampling points. More specifically, the D-optimality criterion is employed to identify, within a sparse temporal data set, the set of time points leading to optimal estimations of the quenched fractional population of the donor fluorophore. Overall, a reduced set of 10 time points (compared to a typical complete set of 90 time points) was identified to have minimal impact on parameter estimation accuracy (≈5%), with in silico and in vivo experiment validations. This reduction of the number of needed time points by almost an order of magnitude allows the use of FLIM-FRET for certain high-throughput applications which would be infeasible if the entire number of time sampling points were used.

  11. FRET-based trilateration of probes bound within functional ryanodine receptors.

    Science.gov (United States)

    Svensson, Bengt; Oda, Tetsuro; Nitu, Florentin R; Yang, Yi; Cornea, Iustin; Chen-Izu, Ye; Fessenden, James D; Bers, Donald M; Thomas, David D; Cornea, Razvan L

    2014-11-04

    To locate the biosensor peptide DPc10 bound to ryanodine receptor (RyR) Ca(2+) channels, we developed an approach that combines fluorescence resonance energy transfer (FRET), simulated-annealing, cryo-electron microscopy, and crystallographic data. DPc10 is identical to the 2460-2495 segment within the cardiac muscle RyR isoform (RyR2) central domain. DPc10 binding to RyR2 results in a pathologically elevated Ca(2+) leak by destabilizing key interactions between the RyR2 N-terminal and central domains (unzipping). To localize the DPc10 binding site within RyR2, we measured FRET between five single-cysteine variants of the FK506-binding protein (FKBP) labeled with a donor probe, and DPc10 labeled with an acceptor probe (A-DPc10). Effective donor positions were calculated from simulated-annealing constrained by both the RyR cryo-EM map and the FKBP atomic structure docked to the RyR. FRET to A-DPc10 was measured in permeabilized cardiomyocytes via confocal microscopy, converted to distances, and used to trilaterate the acceptor locus within RyR. Additional FRET measurements between donor-labeled calmodulin and A-DPc10 were used to constrain the trilaterations. Results locate the DPc10 probe within RyR domain 3, ?35 Å from the previously docked N-terminal domain crystal structure. This multiscale approach may be useful in mapping other RyR sites of mechanistic interest within FRET range of FKBP.

  12. Microstructure and Wear Behavior of FeBSiNbCr Metallic Glass Coatings

    Institute of Scientific and Technical Information of China (English)

    Jiangbo Cheng; Xiubing Liang; Binshi Xu; Yixiong Wu

    2009-01-01

    In this paper, FeBSiNbCr metallic glass coatings were prepared onto AISI 1045 steel substrate by using wire arc spraying process. The phase and structure of the coating were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD) and scanning election microscopy (SEM) equipped with energy dispersive X-ray analysis (EDX). The microstructure of the coating consists of full amorphous phase. The coating has high hardness and low porosity. Full density and little oxides are detected in the coating. The mechanical properties, especially wear resistance, were investigated. The relationship between wear behavior and structure of the coatings were analyzed in detail. The main failure mechanism of the metallic glass coating is brittle breaking and fracture. The results indicate that FeBSiNbCr metallic glass coating has excellent resistance to abrasive wear.

  13. Electroporation and microinjection successfully deliver single-stranded and duplex DNA into live cells as detected by FRET measurements.

    Directory of Open Access Journals (Sweden)

    Rosemary A Bamford

    Full Text Available Förster resonance energy transfer (FRET technology relies on the close proximity of two compatible fluorophores for energy transfer. Tagged (Cy3 and Cy5 complementary DNA strands forming a stable duplex and a doubly-tagged single strand were shown to demonstrate FRET outside of a cellular environment. FRET was also observed after transfecting these DNA strands into fixed and live cells using methods such as microinjection and electroporation, but not when using lipid based transfection reagents, unless in the presence of the endosomal acidification inhibitor bafilomycin. Avoiding the endocytosis pathway is essential for efficient delivery of intact DNA probes into cells.

  14. Wear Characteristics of Metallic Biomaterials: A Review

    Directory of Open Access Journals (Sweden)

    Mohamed A. Hussein

    2015-05-01

    Full Text Available Metals are extensively used in a variety of applications in the medical field for internal support and biological tissue replacements, such as joint replacements, dental roots, orthopedic fixation, and stents. The metals and alloys that are primarily used in biomedical applications are stainless steels, Co alloys, and Ti alloys. The service period of a metallic biomaterial is determined by its abrasion and wear resistance. A reduction in the wear resistance of the implant results in the release of incompatible metal ions into the body that loosen the implant. In addition, several reactions may occur because of the deposition of wear debris in tissue. Therefore, developing biomaterials with high wear resistance is critical to ensuring a long life for the biomaterial. The aim of this work is to review the current state of knowledge of the wear of metallic biomaterials and how wear is affected by the material properties and conditions in terms of the type of alloys developed and fabrication processes. We also present a brief evaluation of various experimental test techniques and wear characterization techniques that are used to determine the tribological performance of metallic biomaterials.

  15. Modular titanium alloy neck adapter failures in hip replacement - failure mode analysis and influence of implant material

    Directory of Open Access Journals (Sweden)

    Bloemer Wilhelm

    2010-01-01

    Full Text Available Abstract Background Modular neck adapters for hip arthroplasty stems allow the surgeon to modify CCD angle, offset and femoral anteversion intraoperatively. Fretting or crevice corrosion may lead to failure of such a modular device due to high loads or surface contamination inside the modular coupling. Unfortunately we have experienced such a failure of implants and now report our clinical experience with the failures in order to advance orthopaedic material research and joint replacement surgery. The failed neck adapters were implanted between August 2004 and November 2006 a total of about 5000 devices. After this period, the titanium neck adapters were replaced by adapters out of cobalt-chromium. Until the end of 2008 in total 1.4% (n = 68 of the implanted titanium alloy neck adapters failed with an average time of 2.0 years (0.7 to 4.0 years postoperatively. All, but one, patients were male, their average age being 57.4 years (36 to 75 years and the average weight 102.3 kg (75 to 130 kg. The failures of neck adapters were divided into 66% with small CCD of 130° and 60% with head lengths of L or larger. Assuming an average time to failure of 2.8 years, the cumulative failure rate was calculated with 2.4%. Methods A series of adapter failures of titanium alloy modular neck adapters in combination with a titanium alloy modular short hip stem was investigated. For patients having received this particular implant combination risk factors were identified which were associated with the occurence of implant failure. A Kaplan-Meier survival-failure-analysis was conducted. The retrieved implants were analysed using microscopic and chemical methods. Modes of failure were simulated in biomechanical tests. Comparative tests included modular neck adapters made of titanium alloy and cobalt chrome alloy material. Results Retrieval examinations and biomechanical simulation revealed that primary micromotions initiated fretting within the modular tapered neck

  16. Wear mechanism and wear prevention in coal-fueled diesel engines. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schwalb, J.A.; Ryan, T.W.

    1991-10-01

    Coal fueled diesel engines present unique wear problems in the piston ring/cylinder liner area because of their tendency to contaminate the lube-oil with high concentrations of highly abrasive particles. This program involved a series of bench-scale wear tests and engine tests designed to investigate various aspects of the ring/liner wear problem and to make specific recommendations to engine manufacturers as to how to alleviate these problems. The program was organized into tasks, designed to accomplish the following objectives: (1) define the predominant wear mechanisms causing accelerated wear in the ring/liner area; (2) investigate the effectiveness of traditional approaches to wear prevention to prevent wear in coal-fueled engines; (3) further refine information on the most promising approaches to wear prevention; (4) present detailed information and recommendations to engine manufacturers on the most promising approach to wear prevention; (5) present a final report covering the entire program; (6)complete engine tests with a coal-derived liquid fuel, and investigate the effects of the fuel on engine wear and emissions.

  17. Wear mechanism and wear prevention in coal-fueled diesel engines

    Energy Technology Data Exchange (ETDEWEB)

    Schwalb, J.A.; Ryan, T.W.

    1991-10-01

    Coal fueled diesel engines present unique wear problems in the piston ring/cylinder liner area because of their tendency to contaminate the lube-oil with high concentrations of highly abrasive particles. This program involved a series of bench-scale wear tests and engine tests designed to investigate various aspects of the ring/liner wear problem and to make specific recommendations to engine manufacturers as to how to alleviate these problems. The program was organized into tasks, designed to accomplish the following objectives: (1) define the predominant wear mechanisms causing accelerated wear in the ring/liner area; (2) investigate the effectiveness of traditional approaches to wear prevention to prevent wear in coal-fueled engines; (3) further refine information on the most promising approaches to wear prevention; (4) present detailed information and recommendations to engine manufacturers on the most promising approach to wear prevention; (5) present a final report covering the entire program; (6)complete engine tests with a coal-derived liquid fuel, and investigate the effects of the fuel on engine wear and emissions.

  18. Dimensional Description of On-line Wear Debris Images for Wear Characterization

    Institute of Scientific and Technical Information of China (English)

    WU Tonghai; PENG Yeping; DU Ying; WANG Junqun

    2014-01-01

    As one of the most wear monitoring indicator, dimensional feature of individual particles has been studied mostly focusing on off-line analytical ferrograph. Recent development in on-line wear monitoring with wear debris images shows that merely wear debris concentration has been extracted from on-line ferrograph images. It remains a bottleneck of obtaining the dimension of on-line particles due to the low resolution, high contamination and particle’s chain pattern of an on-line image sample. In this work, statistical dimension of wear debris in on-line ferrograph images is investigated. A two-step procedure is proposed as follows. First, an on-line ferrograph image is decomposed into four component images with different frequencies. By doing this, the size of each component image is reduced by one fourth, which will increase the efficiency of subsequent processing. The low-frequency image is used for extracting the area of wear debris, and the high-frequency image is adopted for extracting contour. Second, a statistical equivalent circle dimension is constructed by equaling the overall wear debris in the image into equivalent circles referring to the extracted total area and premeter of overall wear debris. The equivalent circle dimension, reflecting the statistical dimension of larger wear debris in an on-line image, is verified by manual measurement. Consequently, two preliminary applications are carried out in gasoline engine bench tests of durability and running-in. Evidently, the equivalent circle dimension, together with the previously developed concentration index, index of particle coverage area (IPCA), show good performances in characterizing engine wear conditions. The proposed dimensional indicator provides a new statistical feature of on-line wear particles for on-line wear monitoring. The new dimensional feature conveys profound information about wear severity.

  19. Prediction of Wear in Crosslinked Polyethylene Unicompartmental Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Jonathan Netter

    2015-05-01

    Full Text Available Wear-related complications remain a major issue after unicompartmental arthroplasty. We used a computational model to predict knee wear generated in vitro under diverse conditions. Inverse finite element analysis of 2 different total knee arthroplasty designs was used to determine wear factors of standard and highly crosslinked polyethylene by matching predicted wear rates to measured wear rates. The computed wear factor was used to predict wear in unicompartmental components. The articular surface design and kinematic conditions of the unicompartmental and tricompartmental designs were different. Predicted wear rate (1.77 mg/million cycles was very close to experimental wear rate (1.84 mg/million cycles after testing in an AMTI knee wear simulator. Finite element analysis can predict experimental wear and may reduce the cost and time of preclinical testing.

  20. Prediction of wear rates in comminution equipment

    DEFF Research Database (Denmark)

    Jensen, Lucas Roald Dörig; Fundal, Erling; Møller, Per

    2010-01-01

    Raw material comminution equipment may be exposed to excessive wear, which makes it difficult to operate minerals processing plants continuously because lengthy and unplanned shut-downs interrupt the overall process. In general, most comminution equipment is fine-tuned to operate at low vibrations......-resistant high chromium white cast iron (21988/JN/HBW555XCr21), a heat-treated wear resistant steel (Hardox 400) and a plain carbon construction steel (S235). Quartz, which accounts for the largest wear loss in the cement industry, was chosen as abrasive. Other process parameters such as velocity (1–7 m...

  1. Wear resistance of reactive plasma sprayed and laser remelted TiB2-TiC0.3N0.7 based composite coatings against medium carbon steel

    Science.gov (United States)

    Mao, Zhengping; Wang, Jun; Sun, Baode; Bordia, Rajendra K.

    2011-01-01

    Wear resistance of reactive plasma sprayed TiB2-TiC0.3N0.7 based composite coatings and the as-sprayed coating with laser surface treatment was investigated using plate-on-plate tests. Wear tests were performed at different normal loads and sliding speeds under dry sliding conditions in air. The surface morphologies of counterparts against as-sprayed and laser remelted coatings were investigated. The microstructure and chemical composition of wear debris and coatings were studied using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), respectively. The results show that the wear resistance of the laser remelted coating is improved significantly due to their increased microhardness and reduced flaws. The primary wear mechanism of the remelted coating is oxidation wear and its minor wear mechanisms are grain abrasion and fatigue failure during the course of wear test. In contrast, the primary wear mechanism of the as-sprayed coating is grain abrasion at the low sliding speed (370 rpm) and fatigue failure at the high sliding speed (549 rpm). The oxidation wear mechanism is a minor contributor for the as-sprayed coating.

  2. Highly sensitive detection of DNA methylation levels by using a quantum dot-based FRET method

    Science.gov (United States)

    Ma, Yunfei; Zhang, Honglian; Liu, Fangming; Wu, Zhenhua; Lu, Shaohua; Jin, Qinghui; Zhao, Jianlong; Zhong, Xinhua; Mao, Hongju

    2015-10-01

    DNA methylation is the most frequently studied epigenetic modification that is strongly involved in genomic stability and cellular plasticity. Aberrant changes in DNA methylation status are ubiquitous in human cancer and the detection of these changes can be informative for cancer diagnosis. Herein, we reported a facile quantum dot-based (QD-based) fluorescence resonance energy transfer (FRET) technique for the detection of DNA methylation. The method relies on methylation-sensitive restriction enzymes for the differential digestion of genomic DNA based on its methylation status. Digested DNA is then subjected to PCR amplification for the incorporation of Alexa Fluor-647 (A647) fluorophores. DNA methylation levels can be detected qualitatively through gel analysis and quantitatively by the signal amplification from QDs to A647 during FRET. Furthermore, the methylation levels of three tumor suppressor genes, PCDHGB6, HOXA9 and RASSF1A, in 20 lung adenocarcinoma and 20 corresponding adjacent nontumorous tissue (NT) samples were measured to verify the feasibility of the QD-based FRET method and a high sensitivity for cancer detection (up to 90%) was achieved. Our QD-based FRET method is a convenient, continuous and high-throughput method, and is expected to be an alternative for detecting DNA methylation as a biomarker for certain human cancers.DNA methylation is the most frequently studied epigenetic modification that is strongly involved in genomic stability and cellular plasticity. Aberrant changes in DNA methylation status are ubiquitous in human cancer and the detection of these changes can be informative for cancer diagnosis. Herein, we reported a facile quantum dot-based (QD-based) fluorescence resonance energy transfer (FRET) technique for the detection of DNA methylation. The method relies on methylation-sensitive restriction enzymes for the differential digestion of genomic DNA based on its methylation status. Digested DNA is then subjected to PCR

  3. Wear analysis of diesel-engine fuel-injection pumps from military ground equipment fueled with Jet A-1. Interim report Jan-May 91

    Energy Technology Data Exchange (ETDEWEB)

    Lacey, P.I.

    1991-05-01

    The U.S. Department of Defense has adopted the single fuel for the battlefield concept. During Operation Desert Shield/Storm, Jet A-1 replaced diesel in many applications. A simultaneous increase in fuel injection pump failures was observed during that operation. Prior to its introduction, a number of studies had indicated that JP-8 is compatible with the current fleet of ground equipment. This report forms part of an ongoing study to define the fuel lubricity requirements of ground equipment. The report also details the wear and failure mechanisms observed from used pumps. The results indicate that, although Jet A-1 does increase wear, many other failure mechanisms are also prevalent.

  4. The predictive analysis of wear work-rates in wear test rigs

    Energy Technology Data Exchange (ETDEWEB)

    Phalippou, C.; Delaune, X.

    1996-12-31

    Impact and sliding wear in components is classically studied, as far as the wear laws are concerned, in specific wear test rigs that simulate the vibratory motion induced by the flow. In this paper, an experimental and numerical study on the impact forces and wear work-rates of a typical AECL rig is presented. The mode shapes and frequencies are measured and compared with finite element computations. Impact and sliding motions between the wear specimens are calculated and compared to the experimental results. Impact forces, mean values of wear work-rates as well as the specimen relative motions are found to be close to the experimental data. (authors). 14 refs., 9 figs., 5 tabs.

  5. EINSTAIN AND FRETTING. BULGAKOV AND QUANTUM MECHANICS. Part 1

    Directory of Open Access Journals (Sweden)

    IVASYSHIN Henrich Stepanovich

    2013-10-01

    Full Text Available Mathematical and tribophysical models based on the increased accuracy of determining physical and mechanical characteristics of materials and aimed at creation of competitive technologies in the field of quantum mechanics applications are considered. In particular the specialist in mechanics, tribology and transport G.S. Gura [5] regards the problems concerning the nature of friction and materials wearing, fundamentals of tribology in his monograph. «…The modern explanation of the theoretical mechanics is based on the principal statements put forward by I. Newton…». «…I. Newton placed the notions of space, time, force and mass at the heart of his mechanics. There is a logical relation between these principal notions and it is expressed in the fundamental laws of Newton mechanics…». «…However the development of science and engineering caused the appearance of new challenges which cannot be solved within the scientific hypotheses proposed by Newton. First of all, that concerns bounded motion of the body. The important restriction in the explanation of the one of the most important fields of the modern engineering mechanics – friction – is the postulate of the rigid body and constancy of its mass…». «…A.Einstein and many other outstanding scientists paid attention to the incompleteness of Newton’s mechanics, they had doubts in absolutism of some basic notions. The concept of Newton force is also restricted semantically in some interactions in quantum mechanics. In the modern models of solid states it is not enough to represent mechanical interactions using Newton forces. This statement can be soundly refered to mechanical systems with friction…». «For centuries many great brains of the world have studied the phenomenon of friction. It was not occasionally when the prominent Russian scientists D.I. Mendeleev (1834–1907 pointed out that the the subject of solid body friction is complex. Many experiments are needed to

  6. Wear and corrosion behavior of W/WC bilayers deposited by magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, N.A. de [Excellence Center for Novel Materials, Universidad del Valle, Cali (Colombia); Jaramillo, H.E. [Science and Engineering of Materials Group, Department of Basic Science of Engineering, Universidad Autonoma de Occidente, Cali (Colombia); Department of Energetic and Mechanic, Universidad Autonoma de Occidente, Cali (Colombia); Bejarano, G. [Excellence Center for Novel Materials, Universidad del Valle, Cali (Colombia); Group for Engineering and Materials Development, CDT ASTIN-SENA, Cali (Colombia); Group of Corrosion and Protection, Antioquia University, Medellin (Colombia); Villamil, B.E.; Teran, G. [Richer Young, COLCIENCIAS, Cali (Colombia)

    2007-07-01

    WC/W coatings were deposited by reactive magnetron sputtering using 40%, 60% and 80% methane CH{sub 4} in the gas mixture. The bilayers were grown on to AISI 420 stainless-steel substrates in order to study the wear and corrosion behavior. Before growing the bilayers, one Ti monolayer was grown to improve the adherence of the coatings to the substrate. The wear resistance and the friction coefficient of the coatings were determined using a pin-on-disk tribometer. All coatings had a friction coefficient of about 0.5. The measured weight lost of the bilayers from each probe allowed the qualitative analysis of wear behavior all coatings. The bilayers grown with 80% methane showed the best abrasive wear resistance and adhesion without failure through the coating in the wear track for dry pin-on-disk sliding. Electrochemical corrosion test showed that the bilayers grown with 80% methane were more resistant to corrosion than the ones uncoated. (copyright 2007 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  7. Wear and transfer characteristics of carbon fiber reinforced polymer composites under water lubrication

    Institute of Scientific and Technical Information of China (English)

    JIA Jun-hong; CHEN Jian-min; ZHOU Hui-di; CHEN Lei

    2004-01-01

    The tribological characteristics of carbon fiber reinforced polymer composites under distilled-water-lubricated-sliding and dry-sliding against stainless steel were comparatively investigated. Scanning electron microscopy (SEM) was utilized to examine composite microstructures and modes of failure. The typical chemical states of elements of the transfer film on the stainless steel were examined with X-ray photoelectron spectroscopy (XPS). Wear testing and SEM analysis show that all the composites hold the lowered friction coefficient and show much better wear resistance under water lubricated sliding against stainless steel than those under dry sliding. The wear of composites is characterized by plastic deformation, scuffing, micro cracking, and spalling under both dry-sliding and water lubricated conditions. Plastic deformation, scuffing, micro cracking, and spalling, however, are significantly abated under water-lubricated condition. XPS analysis conforms that none of the materials produces transfer films on the stainless steel counterface with the type familiar from dry sliding, and the transfer of composites onto the counterpart ring surface is significantly hindered while the oxidation of the stainless steel is speeded under water lubrication. The composites hinder transfer onto the steel surface and the boundary lubricating action of water accounts for the much smaller wear rate under water lubrication compared with that under dry sliding. The easier transfer of the composite onto the counterpart steel surface accounts for the larger wear rate of the polymer composite under dry sliding.

  8. Comparison of Wear Resistance Between Innovative Composites and Nano- and Microfilled Composite Resins

    Directory of Open Access Journals (Sweden)

    Asefi

    2016-02-01

    Full Text Available Background One of the most common causes of failure in class 2 posterior composite restorations is occlusal and proximal wear. Estelite composites used supra-nano monodispersing spherical fillers and a new photoinitiator, and the manufacturer claimed that the wear of these composites is less than 1 mm3 volumetric wear. Objectives Compare the wear resistance of new Estelite composites with that of other composites generations. Materials and Methods Thirty-five specimens were evaluated in five groups: three kinds of Estelite composites (Estelite Sigma Quick, Estelite Flow Quick, and Estelite Flow Quick High Flow, Filtek Z350, and Filtek Z250. All specimens were prepared in 25 mm disks and cured with laboratory light for 120 seconds (60 s for each side. Then, they were polished by 600 grit sand paper and stored for one week in distilled water at room temperature. We used a two-body abrasion test and the pin-on-disk method with distilled water as medium. All specimens were worn under 15 N load, 0.05 m/seconds speed, 100 m distance, and steatite ceramic balls antagonists. After wearing, we measured wear volume by calculating the wear track cross-section area with a profilometer and analyzed the data with the one-way analysis of variance (ANOVA test. Results The wear amounts of the composites are as follows in order: Estelite sigma quick (1886.9 ± 518.5 μm2, Estelite flow quick (2708.9 ± 578.1 μm2, Estelite high flow (3206 ± 2445.1 μm2, Filtek Z350 (3840 ± 1963.4 μm2, and Filtek Z250 (4667.2 ± 2351.1 μm2. No statistical difference was found among the groups (P value > 0.05. Conclusions Estelite sigma quick composite had wear resistance similar to that of nano- and microfilled composites. Estelite flowable composites demonstrated similar wear resistance to that of a posterior composite.

  9. Wear mechanism and wear prevention in coal-fueled diesel engines

    Energy Technology Data Exchange (ETDEWEB)

    Schwalb, J.A.

    1991-06-01

    Contamination of the lube-oil with hard abrasive particles leads to a three-body abrasive wear mechanism that highly accelerates piston ring/cylinder liner wear in coal-fueled diesel engines. One approach to reducing that wear is to modify the size and orientation of surface asperities on the cylinder to enhance the formation of a hydrodynamic film, and to provide avenues of escape for particles that would otherwise be trapped in the wear zone. Another approach is to introduce additives into the contaminated lube-oil that further enhance hydrodynamic film formation, form chemical films on the wearing surfaces, or form films on the contaminant particles. This work focuses on defining the effects of cylinder liner surface finish, various configurations of slots in the cylinder liner surface, and various additives in the contaminated lube-oil on the wear process. Wear tests were initiated in a bench apparatus using coal-ash contaminated lube-oil to test the various wear configurations. The results of these tests indicate that the formation of a hydrodynamic film between the ring and cylinder specimens is enhanced by increasing surface roughness, and by orienting the surface asperities normal to the direction of ring travel but modifications to the cylinder liner surface did not greatly reduce the wear rate. Additives to the lubricant seemed to have a much more significant effect on wear, with a dispersant additive highly accelerating the wear, while a detergent additive was able to reduce the wear almost to the rate achieved where there was no contaminant.

  10. Systems failure.

    OpenAIRE

    Macleod, Anna

    1998-01-01

    Systems Failure A solo exhibition of new work by Anna Macleod developed in conversation with curator Liz Burns. The Dock, Carrick on Shannon, Co Leitrim. Ireland. 12th February – 17th April 2010. The works for the exhibition Systems Failure include drawings, prints and small constructions that examine the delicate balance that exists between need and aspects of failure rooted in the relationship between humanity and land use. The work seeks to question the relationship between scient...

  11. STUDIES ON TOOL WEAR CONDITION MONITORING

    Directory of Open Access Journals (Sweden)

    Hüseyin Metin ERTUNÇ

    2001-01-01

    Full Text Available In this study, wear mechanisms on cutting tools, especially for the drill bits, during the cutting operation have been investigated. As the importance of full automation in industry has gained substantial importance, tool wear condition monitoring during the cutting operation has been the subject of many investigators. Tool condition monitoring is very crucial in order to change the tool before breakage. Because tool breakage can cause considerable economical damage to both the machine tool and workpiece. In this paper, the studies on the monitoring of drill bit wear in literature have been introduced; the direct/indirect techniques used and sensor fusion techniques have been summarized. The methods which were proposed to determine tool wear evolution as processing the sensor signals collected have been provided and their references have been given for detailed information.

  12. Homo-FRET Based Biosensors and Their Application to Multiplexed Imaging of Signalling Events in Live Cells

    Science.gov (United States)

    Warren, Sean C.; Margineanu, Anca; Katan, Matilda; Dunsby, Chris; French, Paul M. W.

    2015-01-01

    Multiplexed imaging of Förster Resonance Energy Transfer (FRET)-based biosensors potentially presents a powerful approach to monitoring the spatio-temporal correlation of signalling pathways within a single live cell. Here, we discuss the potential of homo-FRET based biosensors to facilitate multiplexed imaging. We demonstrate that the homo-FRET between pleckstrin homology domains of Akt (Akt-PH) labelled with mCherry may be used to monitor 3′-phosphoinositide accumulation in live cells and show how global analysis of time resolved fluorescence anisotropy measurements can be used to quantify this accumulation. We further present multiplexed imaging readouts of calcium concentration, using fluorescence lifetime measurements of TN-L15-a CFP/YFP based hetero-FRET calcium biosensor-with 3′-phosphoinositide accumulation. PMID:26133241

  13. Graphene and graphene-like two-denominational materials based fluorescence resonance energy transfer (FRET) assays for biological applications.

    Science.gov (United States)

    Tian, Feng; Lyu, Jing; Shi, Jingyu; Yang, Mo

    2017-03-15

    In the past decades, Förster resonance energy transfer (FRET) has been applied in many biological applications to reveal the biological information at the nanoscale. Recently, graphene and graphene-like two-dimensional (2D) nanomaterials started to be used in FRET assays as donors or acceptors including graphene oxide (GO), graphene quantum dot (GQD), graphitic-carbon nitride nanosheets (g-C3N4) and transition metal dichalcogenides (e.g. MoS2, MnO2, and WS2). Due to the remarkable properties such as large surface to volume ratio, tunable energy band, photoluminescence and excellent biocompatibility, these 2D nanomaterials based FRET assays have shown great potential in various biological applications. This review summarizes the recent development of graphene and graphene-like 2D nanomaterials based FRET assays in applications of biosensing, bioimaging, and drug delivery monitoring.

  14. Wear behavior of austenite containing plate steels

    Science.gov (United States)

    Hensley, Christina E.

    As a follow up to Wolfram's Master of Science thesis, samples from the prior work were further investigated. Samples from four steel alloys were selected for investigation, namely AR400F, 9260, Hadfield, and 301 Stainless steels. AR400F is martensitic while the Hadfield and 301 stainless steels are austenitic. The 9260 exhibited a variety of hardness levels and retained austenite contents, achieved by heat treatments, including quench and tempering (Q&T) and quench and partitioning (Q&P). Samples worn by three wear tests, namely Dry Sand/Rubber Wheel (DSRW), impeller tumbler impact abrasion, and Bond abrasion, were examined by optical profilometry. The wear behaviors observed in topography maps were compared to the same in scanning electron microscopy micrographs and both were used to characterize the wear surfaces. Optical profilometry showed that the scratching abrasion present on the wear surface transitioned to gouging abrasion as impact conditions increased (i.e. from DSRW to impeller to Bond abrasion). Optical profilometry roughness measurements were also compared to sample hardness as well as normalized volume loss (NVL) results for each of the three wear tests. The steels displayed a relationship between roughness measurements and observed wear rates for all three categories of wear testing. Nanoindentation was used to investigate local hardness changes adjacent to the wear surface. DSRW samples generally did not exhibit significant work hardening. The austenitic materials exhibited significant hardening under the high impact conditions of the Bond abrasion wear test. Hardening in the Q&P materials was less pronounced. The Q&T microstructures also demonstrated some hardening. Scratch testing was performed on samples at three different loads, as a more systematic approach to determining the scratching abrasion behavior. Wear rates and scratch hardness were calculated from scratch testing results. Certain similarities between wear behavior in scratch testing

  15. A Study of Slipper and Rail Wear Interaction at Low Speed

    Science.gov (United States)

    2014-06-19

    taking care of the boys, a house and a dog and for not getting discouraged. I pray that they will learn as I have how important it is to ensure Yahovah...wear, delamination wear, seizure wear, melt wear, severe oxidational wear and adhesive wear. Adhesive wear comprised of three zones: low speed...model is experiencing seizure or melt wear, then something is wrong with the model. Lim and Ashby also published on their wear map the normalized wear

  16. Third abrasive wear mode: is it possible?

    Directory of Open Access Journals (Sweden)

    Ronaldo Câmara Cozza

    2014-04-01

    Full Text Available The objective of this paper is to propose an initial discussion on the characterization of a third abrasive wear mode. The results obtained in a previous work [1] under different test conditions revealed the occurrence of the superposition of the “rolling” and “grooving” abrasive wear modes. This phenomenon was denoted “micro-rolling abrasion” due to the observation that “rolling abrasion” was found to act on “grooving abrasion”.

  17. Biotribology :articular cartilage friction, wear, and lubrication

    OpenAIRE

    Schroeder, Matthew O

    1995-01-01

    This study developed, explored, and refined techniques for the in vitro study of cartilage-on-cartilage friction, deformation, and wear. Preliminary results of in vitro cartilage-on- cartilage experiments with emphasis on wear and biochemistry are presented. Cartilage-bone specimens were obtained from the stifle joints of steers from a separate controlled study. The load, sliding speed, and traverse of the lower specimens were held constant as lubricant and test length were varied. Lubric...

  18. A review on failure characteristics of polymer gear

    Directory of Open Access Journals (Sweden)

    Md Ghazali Wafiuddin

    2017-01-01

    Full Text Available Polymer are now widely used as substitute material for steel gear in low load devices. Its failure differs from gears made of steel, thus it is important to categorize the failures shown by polymer gears. Several previous studies noted that wear detection, microstructure surface condition monitoring, weight loss and temperature detection can be used in detecting failure of polymer gear. This article reviews the failure detection method mentioned above. Other researcher works were studied and their findings were extracted in order to identify the methods they used. The most common method used was wear detection and it was supplemented by other methods such as microstructure surface condition monitoring. Failures shown by polymer can be concluded to be tooth breakage, tooth deformation, material removal and surface fatigue.

  19. Pseudomembranous candidiasis in patient wearing full denture

    Directory of Open Access Journals (Sweden)

    Nurdiana Nurdiana

    2009-06-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection of the oral cavity caused by an overgrowth of Candida species, the commonest being Candida albicans. Candida albicans is a harmless commensal organism inhabiting the mouths but it can change into pathogen and invade tissue and cause acute and chronic disease. Dentures predispose to infection with Candida in as many as 65% of elderly people wearing full upper dentures. Purpose: The purpose of this case report is to discuss thrush in patient wearing full denture which rapidly developed. Case: This paper report a case of 57 year-old man who came to the Oral Medicine Clinic Faculty of Dentistry Airlangga University with clinical appearance of pseudomembranous candidiasis (thrush. Case Management: Diagnosis of this case is confirmed with microbiology examination. Patient was wearing full upper dentures, and from anamnesis known that patient wearing denture for 24 hours and he had poor oral hygiene. Patient was treated with topical (nystatin oral suspension and miconazole oral gel and systemic (ketoconazole antifungal. Patient also instructed not to wear his denture and cleaned white pseudomembrane on his mouth with soft toothbrush. Conclusion: Denture, habit of wearing denture for 24 hours, and poor oral hygiene are predisposing factors of thrush and it can healed completely after treated with topical and systemic antifungal.

  20. Terbium to Quantum Dot FRET Bioconjugates for Clinical Diagnostics: Influence of Human Plasma on Optical and Assembly Properties

    Directory of Open Access Journals (Sweden)

    Niko Hildebrandt

    2011-10-01

    Full Text Available Förster resonance energy transfer (FRET from luminescent terbium complexes (LTC as donors to semiconductor quantum dots (QDs as acceptors allows extraordinary large FRET efficiencies due to the long Förster distances afforded. Moreover, time-gated detection permits an efficient suppression of autofluorescent background leading to sub-picomolar detection limits even within multiplexed detection formats. These characteristics make FRET-systems with LTC and QDs excellent candidates for clinical diagnostics. So far, such proofs of principle for highly sensitive multiplexed biosensing have only been performed under optimized buffer conditions and interactions between real-life clinical media such as human serum or plasma and LTC-QD-FRET-systems have not yet been taken into account. Here we present an extensive spectroscopic analysis of absorption, excitation and emission spectra along with the luminescence decay times of both the single components as well as the assembled FRET-systems in TRIS-buffer, TRIS-buffer with 2% bovine serum albumin, and fresh human plasma. Moreover, we evaluated homogeneous LTC-QD FRET assays in QD conjugates assembled with either the well-known, specific biotin-streptavidin biological interaction or, alternatively, the metal-affinity coordination of histidine to zinc. In the case of conjugates assembled with biotin-streptavidin no significant interference with the optical and binding properties occurs whereas the histidine-zinc system appears to be affected by human plasma.

  1. Evaluation of quantum dot-based concentric FRET configurations with a fluorescent dye and dark quencher for multiplexed bioanalyses

    Science.gov (United States)

    Conroy, Erin M.; Algar, W. Russ

    2014-03-01

    Semiconductor quantum dots (QDs) continue to emerge as a highly advantageous platform for bioanalysis. Their unique physical and optical properties are especially well suited for Förster resonance energy transfer (FRET)-based bioprobes. Concentric FRET configurations are a recent development in this area of research and are best described as QD bioconjugates where multiple energy transfer pathways have been assembled around the central QD. Concentric FRET configurations permit multiplexed bioanalysis using one type of QD vector, but require more sophisticated analyses than conventional FRET pairs. In this paper, we describe the design and characterization of a new concentric FRET configuration that assembles both a fluorescent dye, Alexa Fluor 555 or Alexa Fluor 647, and a dark quencher, QSY9, at different ratios around a central CdSeS/ZnS QD. It was found that the magnitudes of the total photoluminescence (PL) intensity and either the A555/QD or A647/QD PL ratio can be related to the number of QSY9 and A555 or A647 per QD. The trends in these parameters with changes in the number of each dye molecule per QD have both similarities and differences between configurations with A555 and A647. In each case, a system of equations can be defined to permit calculation of the number of each dye molecule per QD from PL measurements. Both of these dark quencher-based concentric FRET configurations are therefore good candidates for quantitative, multiplexed bioanalysis.

  2. FRET-based nanoscale point-to-point and broadcast communications with multi-exciton transmission and channel routing.

    Science.gov (United States)

    Kuscu, Murat; Akan, Ozgur B

    2014-09-01

    Nanoscale communication based on Förster Resonance Energy Transfer (FRET) enables nanoscale single molecular devices to communicate with each other utilizing excitons generated on fluorescent molecules as information carriers. Based on the point-to-point single-exciton FRET-based nanocommunication model, we investigate the multiple-exciton case for point-to-point and broadcast communications following an information theoretical approach and conducting simulations through Monte Carlo approach. We demonstrate that the multi-exciton transmission significantly improves the channel reliability and the range of the communication up to tens of nanometers for immobile nanonodes providing high data transmission rates. Furthermore, our analyses indicate that multi-exciton transmission enables broadcasting of information from a transmitter nanonode to many receiver nanonodes pointing out the potential of FRET-based communication to extend over nanonetworks. In this study, we also propose electrically and chemically controllable routing mechanisms exploiting the strong dependence of FRET rate on spectral and spatial characteristics of fluorescent molecules. We show that the proposed routing mechanisms enable the remote control of information flow in FRET-based nanonetworks. The high transmission rates obtained by multi-exciton scheme for point-to-point and broadcast communications, as well as the routing opportunities make FRET-based communication promising for future molecular computers.

  3. Wear Property of Cast Steel Wheel Material in Rail Truck

    Institute of Scientific and Technical Information of China (English)

    MI Guo-fa; LIU Yan-lei; ZHANG Bin; FU Xiu-qin; ZHANG Hong; SONG Guo-xiang

    2009-01-01

    Wear property of material plays a key role in the service time of workpiece.A major objective in the development of new wheel materials is to improve the wear performance.The wear property of B and B+ grade cast steel materials was reported.The results showed that B+ grade cast steel material exhibited better wear property than the B grade material.Carbon content related to the hardness match was the principal factor affecting the wear properties.

  4. Wear-resistance of Aluminum Matrix Microcomposite Materials

    Directory of Open Access Journals (Sweden)

    M. Kandeva

    2011-03-01

    Full Text Available A procedure is developed for the study of wear of aluminum alloys AlSi7 obtained by casting, reinforced by TiC microparticles, before and after heat treatment. Tribological study is realized under conditions of friction on counterbody with fixed abrasive. Experimental results were obtained for mass wear, wear rate, wear intensity and wear-resistance of the alloys with different wt% of microparticles.

  5. Impact of UHMWPE texture on friction and wear resistance of hip prosthesis

    Directory of Open Access Journals (Sweden)

    Eddoumy Fatima

    2013-11-01

    Full Text Available Ultra High Molecular Weight PolyEthylene (UHMWPE is a polymer widely used in hip implants (prostheses as a bearing surface against metal, because of its good mechanical properties and biocompatibility [1]. Nevertheless, the durability of such implants is limited because of failure resulting from osteolysis and aseptic loosening. These two phenomenons are due to the immune response of human body consecutive to the apparition of wear particles of UHMWPE with time.

  6. Ratiometric FRET-based detection of DNA and micro-RNA in solution

    Energy Technology Data Exchange (ETDEWEB)

    Matveeva, Evgenia G., E-mail: ematveev@hsc.unt.ed [Center for Commercialization of Fluorescence Technologies, University of North Texas Health Science Center, Department of Molecular Biology and Immunology and Department of Cell Biology and Genetics, 3500 Camp Bowie Boulevard, Fort Worth, TX 76107 (United States); Gryczynski, Zygmunt [Center for Commercialization of Fluorescence Technologies, University of North Texas Health Science Center, Department of Molecular Biology and Immunology and Department of Cell Biology and Genetics, 3500 Camp Bowie Boulevard, Fort Worth, TX 76107 (United States); Stewart, Donald R. [Omm Scientific, Inc., 2600 N. Stemmons Freeway, Suite 129, Dallas, TX 75207 (United States); Gryczynski, Ignacy [Center for Commercialization of Fluorescence Technologies, University of North Texas Health Science Center, Department of Molecular Biology and Immunology and Department of Cell Biology and Genetics, 3500 Camp Bowie Boulevard, Fort Worth, TX 76107 (United States)

    2009-11-15

    A ratiometric method for detecting DNA oligomers in bulk solution based on Foerster resonance energy transfer (FRET) is described. The two fluorescence signals (green and red), originating from Cy3 (donor, green) and Cy5 (acceptor, red) labels, are simultaneously detected from the pre-hybridized Cy3oligomerY:Cy5oligomerX system. The ratio of red to green intensities is sensitive to the presence of the single-stranded complimentary oligomer, which replaces single-stranded Cy3oligomerY in the donor:acceptor complex and perturbs the FRET. The detection scheme is generally applicable to the detection of DNA and RNA, and particularly micro-RNA. The proposed method is applicable to various double-stranded various lengths targets (manipulation of the sample preparation conditions, such as temperature, incubation time, denaturizing agent, may be needed).

  7. Kinetic Studies of Lysine Riboswitch Folding Using Single-Molecule FRET

    Science.gov (United States)

    Fiegland, Larry; Garst, Andrew; Fiore, J.; Batey, Robert; Nesbitt, David

    2010-03-01

    Riboswitches regulate gene expression through conformational changes induced by metabolite binding. This regulation of gene expression depends on the kinetics of metabolite binding and structural changes. Therefore, an understanding of these dynamics is crucial to developing a compete knowledge of riboswitch functionality. To probe the binding of a metabolite and subsequent folding, a metabolite-binding domain of the Bacillus subtilis lysine riboswitch was transcribed and hybridized to a fluorescent-labeled RNA strand, which allows FRET monitoring of ligand-induced conformational changes. The RNA construct was studied using single-molecule FRET methods that allowed for characterization of the folding dynamics. In the presence of lysine, we observed two states, of which the relative populations are perturbed by lysine concentration. We measured the folding and unfolding rates of the inter-conversion between these states. We also observe that [Mg^2+] affects the lysine-free conformation and the lysine sensitivity of the riboswitch.

  8. High-efficiency FRET-enhanced photoacoustic probes for in vivo tumor imaging

    Science.gov (United States)

    Qin, Huan; Liu, Liming

    2017-01-01

    Photoacoustic imaging can provide high-resolution and high-contrast image under unprecedented depth compared with pure optical imaging techniques by making use of laser-induced ultrasound waves. Although a series of absorption-enhanced optical contrast agents for photoacoustic imaging were developed, the probe with fully conversion from absorbed light energy to acoustic energy has not been achieved so far. Here we develop a high-efficiency photoacoustic probes with fluorescence resonance energy transfer (FRET) effect for enhancement of nonradiative energy. Graphene oxide (GO) binding optical dyes (GO-dyes) were achieved to show highly fluorescence quenching and violently increased photoacoustic signal intensity. GO-dyes were constructed and testified for multi-spectral photoacoustic imaging. As a representative probe, GO-Cy7 nanoparticles were used to validate the feasibility of photoacoustic tumor molecular imaging in vivo. Our work demonstrated a new approach to construct high-efficiency FRET-enhanced multi-spectrum probes for photoacoustic molecular imaging.

  9. Photodynamic therapy via FRET following bioorthogonal click reaction in cancer cells.

    Science.gov (United States)

    Bio, Moses; Rajaputra, Pallavi; You, Youngjae

    2016-01-01

    Longer wavelength light (650-800nm) is desired to treat large tumors in photodynamic therapy (PDT). However, shorter wavelength light is needed in PDT for thin tumors, not to cause undesirable local side effects. We proposed a strategy for stepwise optical imaging and PDT using a bioorthogonal click chemistry and fluorescence resonance energy transfer (FRET). We prepared azidyl rhodamine (Rh-N3, clickable FD) and cyclooctynyl phthalocyanine [Pc-(DIBAC), clickable PS], with which, here, we demonstrate that the non-catalytic click chemistry is rapid and efficient in cancer cells and FRET from a fluorescence dye (FD) to a photosensitizer (PS) is sufficient to generate enough singlet oxygen killing cancer cells by using shorter wavelength light. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Coverage-dependent changes of cytochrome c transverse location in phospholipid membranes revealed by FRET.

    Science.gov (United States)

    Domanov, Yegor A; Molotkovsky, Julian G; Gorbenko, Galyna P

    2005-10-01

    The method of fluorescence resonance energy transfer (FRET) has been employed to monitor cytochrome c interaction with bilayer phospholipid membranes. Liposomes composed of phosphatidylcholine and varying amounts of anionic lipid cardiolipin (CL) were used as model membranes. Trace amount of fluorescent lipid derivative, anthrylvinyl-phosphatidylcholine was incorporated into the membranes to serve energy donor for heme moiety of cytochrome c. Energy transfer efficiency was measured at different lipid and protein concentrations to obtain extensive set of data, which were further analyzed globally in terms of adequate models of protein adsorption and energy transfer on the membrane surface. It has been found that the cytochrome c association with membranes containing 10 mol% CL can be described in terms of equilibrium binding model (yielding dissociation constant Kd = 0.2-0.4 microM and stoichiometry n = 11-13 lipid molecules per protein binding site) combined with FRET model assuming uniform acceptor distribution with the distance of 3.5-3.6 nm between the bilayer midplane and heme moiety of cytochrome c. However, increasing the CL content to 20 or 40 mol% (at low ionic strength) resulted in a different behavior of FRET profiles, inconsistent with the concepts of equilibrium adsorption of cytochrome c at the membrane surface and/or uniform acceptor distribution. To explain this fact, several possibilities are analyzed, including cytochrome c-induced formation of non-bilayer structures and clusters of charged lipids, or changes in the depth of cytochrome c penetration into the bilayer depending on the protein surface density. Additional control experiments have shown that only the latter process can explain the peculiar concentration dependences of FRET at high CL content.

  11. Topographical Analysis of Fretted Terrain: Implications for Ancient Martian Super-eruptions

    Science.gov (United States)

    Mason, K. A.; Bleacher, J. E.; Whelley, P.

    2016-12-01

    Recent work has identified Late Noachian to Early Hesperian plains-style caldera complexes on Mars in western Arabia Terra (AT), eruptions from which might have produced widespread volcanic deposits throughout AT and the entire planet. AT is composed of 2 km thick friable and fretted Late Noachian to Early Hesperian material. Although an ash deposit origin has been suggested for the friable material due to its low thermal inertia, layering, thickness, sulfate abundance, zonal indurations and draped morphology, prior to 2013 no volcanic sources with ability to produce such a deposit were known, and therefore the existence of extensive ash deposits on AT was thought unlikely. Due to recent identification of evidence for ancient super-eruptions in AT such as Eden Patera, the geomorphology of the fretted material warrants reexamination. This study involves a quantitative analysis of eroded valleys throughout the fretted terrain visible at Mars Orbiter Laser Altimeter (MOLA) Digital Elevation Model (DEM) resolution (463 m). These erosion features are mapped objectively via the D8 flow direction algorithm, a technique developed for delineating watersheds with DEMs. The features are then partitioned based on depth and location. Valley orientations are measured for each feature segment and plotted on rose diagrams. To study valley formation mechanisms we use the ratio between high and low stream order lengths (bifurcation ratio) as well as the variance between orientation and primary slope direction. On Earth, bifurcation ratios > 3 and 5 indicate other processes principally formed the valleys and are consistent with the deformation of welded and fractured volcanic deposits. Valleys east of Isidis basin (IB) have bifurcation ratios process throughout the study area. We propose that the AT fretted terrain resembles a network of valleys formed by exploiting angular cooling and compaction fractures in a Late Noachian to Early Hesperian volcanic deposit.

  12. FRET-Based Localization of Fluorescent Protein Insertions Within the Ryanodine Receptor Type 1

    OpenAIRE

    Raina, Shweta A.; Jeffrey Tsai; Montserrat Samsó; Fessenden, James D.

    2012-01-01

    Fluorescent protein (FP) insertions have often been used to localize primary structure elements in mid-resolution 3D cryo electron microscopic (EM) maps of large protein complexes. However, little is known as to the precise spatial relationship between the location of the fused FP and its insertion site within a larger protein. To gain insights into these structural considerations, Förster resonance energy transfer (FRET) measurements were used to localize green fluorescent protein (GFP) inse...

  13. FRET enhancement close to gold nanoparticles positioned in DNA origami constructs.

    Science.gov (United States)

    Aissaoui, Nesrine; Moth-Poulsen, Kasper; Käll, Mikael; Johansson, Peter; Wilhelmsson, L Marcus; Albinsson, Bo

    2017-01-05

    Here we investigate the energy transfer rates of a Förster resonance energy transfer (FRET) pair positioned in close proximity to a 5 nm gold nanoparticle (AuNP) on a DNA origami construct. We study the distance dependence of the FRET rate by varying the location of the donor molecule, D, relative to the AuNP while maintaining a fixed location of the acceptor molecule, A. The presence of the AuNP induces an alteration in the spontaneous emission of the donor (including radiative and non-radiative rates) which is strongly dependent on the distance between the donor and AuNP surface. Simultaneously, the energy transfer rates are enhanced at shorter D-A (and D-AuNP) distances. Overall, in addition to the direct influence of the acceptor and AuNP on the donor decay there is also a significant increase in decay rate not explained by the sum of the two interactions. This leads to enhanced energy transfer between donor and acceptor in the presence of a 5 nm AuNP. We also demonstrate that the transfer rate in the three "particle" geometry (D + A + AuNP) depends approximately linearly on the transfer rate in the donor-AuNP system, suggesting the possibility to control FRET process with electric field induced by 5 nm AuNPs close to the donor fluorophore. It is concluded that DNA origami is a very versatile platform for studying interactions between molecules and plasmonic nanoparticles in general and FRET enhancement in particular.

  14. Handheld Fluorescence Resonance Energy Transfer (FRET)-Aptamer Sensor for Bone Markers

    Science.gov (United States)

    Bruno, John G.

    2015-01-01

    Astronauts lose significant bone mass during lengthy space flights. NASA wishes to monitor this bone loss in order to develop nutritional and exercise countermeasures. Operational Technologies Corporation (OpTech) has developed a handheld device that quantifies bone loss in a spacecraft environment. The innovation works by adding fluorescent dyes and quenchers to aptamers to enable pushbutton, one-step bind-and-detect FRET assays that can be freeze-dried, rehydrated with body fluids, and used to quantify bone loss.

  15. Influence of Cutting Parameters on Chatter and Tool Wear During End Milling of Stainless Steel Conducted on VMC

    Directory of Open Access Journals (Sweden)

    A.K.M.N. AMIN, M. IMRAN AND M. ARIF

    2012-09-01

    Full Text Available Stainless steels are a group of difficult to machine work materials. The difficulty in machining stainless steels is manifested in high contact length and stresses, formation of serrated chips and development of chatter resulting in high tool wear rates and poor machined surface finish. The paper focuses on the performance of TiN coated-carbide inserts in machining stainless steel specimens in end milling operation performed on vertical machining centre (VMC. The performance of the tool is evaluated from the point of view of its wear intensity, mechanism of failure and generation and effect of chatter on tool wear and vice versa. The investigations were aimed at determining the effect of cutting parameters, specifically cutting speed, feed and depth of cut, on chatter amplitude, tool wear rate, mechanism of tool wear and using these data and machined surface roughness values from previous work to come up with recommended values of cutting parameters for semi-finish and finish end milling operation of stainless steel work materials. For recording vibration signals a dual channel portable signal analyzers was used and the signals were analyzed using Pulse Multi-analyzer version 4.2 software. Tool wear was measured using an optical microscope with digital readout capabilities along 3 axes. The tool wear mechanisms were studied under a scanning electron microscope (SEM. Results of the investigation show that acceleration amplitudes generally increase with cutting speed and the magnitude of tool flank wears. It has been also found that an increase in feed and depth of cut leads to higher acceleration amplitudes. The most common wear mechanisms observed during machining of stainless steel are attrition, micro and macro chipping of the tool at lower cutting speeds, and diffusion and mechanical failures due to intensive chatter at higher speeds. It has been also established that stable cutting speeds with relatively low tool wear intensity and

  16. Time-dependent FRET with single enzymes: domain motions and catalysis in H(+)-ATP synthases.

    Science.gov (United States)

    Bienert, Roland; Zimmermann, Boris; Rombach-Riegraf, Verena; Gräber, Peter

    2011-02-25

    H(+)-ATP synthases are molecular machines which couple transmembrane proton transport with ATP synthesis from ADP and inorganic phosphate by a rotational mechanism. Single-pair fluorescence resonance energy transfer (spFRET) in single molecules is a powerful tool to analyse conformational changes. It is used to investigate subunit movements in H(+)-ATP synthases from E. coli (EF(0)F(1)) and from spinach chloroplasts (CF(0)F(1)) during catalysis. The enzymes are incorporated into liposome membranes, and this allows the generation of a transmembrane pH difference, which is necessary for ATP synthesis. After labelling of appropriate sites on different subunits with fluorescence donor and acceptor, the kinetics of spFRET are measured. Analysis of the E(FRET) traces reveals rotational movement of the ε and γ subunits in 120° steps with opposite directions during ATP synthesis and ATP hydrolysis. The stepped movement is characterized by a 120° step faster than 1 ms followed by a rest period with an average dwell time of 15 ms, which is in accordance with the turnover time of the enzyme. In addition to the three conformational states during catalysis, also an inactive conformation is found, which is observed after catalysis.

  17. Live imaging of protein kinase activities in transgenic mice expressing FRET biosensors.

    Science.gov (United States)

    Kamioka, Yuji; Sumiyama, Kenta; Mizuno, Rei; Sakai, Yoshiharu; Hirata, Eishu; Kiyokawa, Etsuko; Matsuda, Michiyuki

    2012-01-01

    Genetically-encoded biosensors based on the principle of Förster resonance energy transfer (FRET) have been widely used in biology to visualize the spatiotemporal dynamics of signaling molecules. Despite the increasing multitude of these biosensors, their application has been mostly limited to cultured cells with transient biosensor expression, due to particular difficulties in the development of transgenic mice that express FRET biosensors. In this study, we report the efficient generation of transgenic mouse lines expressing heritable and functional biosensors for ERK and PKA. These transgenic mice were created by the cytoplasmic co-injection of Tol2 transposase mRNA and a circular plasmid harbouring Tol2 recombination sites. High expression of the biosensors in a wide range of cell types allowed us to screen newborn mice simply by inspection. Observation of these transgenic mice by two-photon excitation microscopy yielded real-time activity maps of ERK and PKA in various tissues, with greatly improved signal-to-background ratios. Our transgenic mice may be bred into diverse genetic backgrounds; moreover, the protocol we have developed paves the way for the generation of transgenic mice that express other FRET biosensors, with important applications in the characterization of physiological and pathological signal transduction events in addition to drug development and screening.

  18. Single-molecule FRET reveals hidden complexity in a protein energy landscape.

    Science.gov (United States)

    Tsytlonok, Maksym; Ibrahim, Shehu M; Rowling, Pamela J E; Xu, Wenshu; Ruedas-Rama, Maria J; Orte, Angel; Klenerman, David; Itzhaki, Laura S

    2015-01-06

    Here, using single-molecule FRET, we reveal previously hidden conformations of the ankyrin-repeat domain of AnkyrinR, a giant adaptor molecule that anchors integral membrane proteins to the spectrin-actin cytoskeleton through simultaneous binding of multiple partner proteins. We show that the ankyrin repeats switch between high-FRET and low-FRET states, controlled by an unstructured "safety pin" or "staple" from the adjacent domain of AnkyrinR. Opening of the safety pin leads to unravelling of the ankyrin repeat stack, a process that will dramatically affect the relative orientations of AnkyrinR binding partners and, hence, the anchoring of the spectrin-actin cytoskeleton to the membrane. Ankyrin repeats are one of the most ubiquitous molecular recognition platforms in nature, and it is therefore important to understand how their structures are adapted for function. Our results point to a striking mechanism by which the order-disorder transition and, thereby, the activity of repeat proteins can be regulated.

  19. A simple approach for measuring FRET in fluorescent biosensors using two-photon microscopy.

    Science.gov (United States)

    Day, Richard N; Tao, Wen; Dunn, Kenneth W

    2016-11-01

    Genetically encoded fluorescent protein (FP)-based biosensor probes are useful tools for monitoring cellular events in living cells and tissues. Because these probes were developed for one-photon excitation approaches, their broad two-photon excitation (2PE) and poorly understood photobleaching characteristics have made their implementation in studies using two-photon laser-scanning microscopy (TPLSM) challenging. Here we describe a protocol that simplifies the use of Förster resonance energy transfer (FRET)-based biosensors in TPLSM. First, the TPLSM system is evaluated and optimized using FRET standards expressed in living cells, which enables the determination of spectral bleed-through (SBT) and the confirmation of FRET measurements from the known standards. Next, we describe how to apply the approach experimentally using a modified version of the A kinase activity reporter (AKAR) protein kinase A (PKA) biosensor as an example-first in cells in culture and then in hepatocytes in the liver of living mice. The microscopic imaging can be accomplished in a day in laboratories that routinely use TPLSM.

  20. FRET Fluctuation Spectroscopy of Diffusing Biopolymers: Contributions of Conformational Dynamics and Translational Diffusion

    Science.gov (United States)

    Gurunathan, Kaushik; Levitus, Marcia

    2009-01-01

    The use of Fluorescence Correlation Spectroscopy (FCS) to study conformational dynamics in diffusing biopolymers requires that the contributions to the signal due to translational diffusion are separated from those due to conformational dynamics. A simple approach that has been proposed to achieve this goal involves the analysis of fluctuations in Fluorescence Resonance Energy Transfer (FRET) efficiency. In this work, we investigate the applicability of this methodology by combining Monte Carlo simulations and experiments. Results show that diffusion does not contribute to the measured fluctuations in FRET efficiency in conditions where the relaxation time of the kinetic process is much shorter than the mean transit time of the molecules in the optical observation volume. However, in contrast to what has been suggested in previous work, the contributions of diffusion are otherwise significant. Neglecting the contributions of diffusion can potentially lead to an erroneous interpretation of the kinetic mechanisms. As an example, we demonstrate that the analysis of FRET fluctuations in terms of a purely kinetic model would generally lead to the conclusion that the system presents complex kinetic behavior even for an idealized two-state system PMID:20030305

  1. FRET based biosensor for detection of active NF-kB

    Science.gov (United States)

    Baldini, Francesco; Citti, Lorenzo; Domenici, Claudio; Giannetti, Ambra; Tedeschi, Lorena; Vo-Dinh, Tuan; Wabuyele, Musundi B.

    2005-05-01

    The Nuclear Factor kB is a transcription factor, ubiquitously expressed, involved in the regulation of a large number of genes and in a variety of human disease including inflammation, asthma, atherosclerosis, AIDS, septic shock, arthritis and cancer. The critical need for a simple and direct method to evaluate the quantity of active NF-kB in a biological sample can be addressed using a suitable and reusable biosensor. For this purpose, a novel method, using fluorescence resonance energy transfer (FRET), to detect the active form of NF-kB binding a specific DNA sequence has been developed. A single-stranded DNA (ssDNA) with auto-complementary sequence has been properly designed and synthesized. In order to evaluate FRET due to the DNA/protein binding interaction taking place between double-stranded DNA (dsDNA) immobilized in a capillary wall and NF-kB proteins, a highly sensitive FRET-based biosensor system developed in our laboratory was used. Preliminary results show that our system was capable of detecting the active form of NF-kB protein with a detection efficiency of about 90% and that the system has a good regenerability.

  2. Monitoring Integrated Activity of Individual Neurons Using FRET-Based Voltage-Sensitive Dyes.

    Science.gov (United States)

    Briggman, Kevin L; Kristan, William B; González, Jesús E; Kleinfeld, David; Tsien, Roger Y

    2015-01-01

    Pairs of membrane-associated molecules exhibiting fluorescence resonance energy transfer (FRET) provide a sensitive technique to measure changes in a cell's membrane potential. One of the FRET pair binds to one surface of the membrane and the other is a mobile ion that dissolves in the lipid bilayer. The voltage-related signal can be measured as a change in the fluorescence of either the donor or acceptor molecules, but measuring their ratio provides the largest and most noise-free signal. This technology has been used in a variety of ways; three are documented in this chapter: (1) high throughput drug screening, (2) monitoring the activity of many neurons simultaneously during a behavior, and (3) finding synaptic targets of a stimulated neuron. In addition, we provide protocols for using the dyes on both cultured neurons and leech ganglia. We also give an updated description of the mathematical basis for measuring the coherence between electrical and optical signals. Future improvements of this technique include faster and more sensitive dyes that bleach more slowly, and the expression of one of the FRET pair genetically.

  3. DNA quantification based on FRET realized by combination with surfactant CPB.

    Science.gov (United States)

    Liu, Chunxia; Wang, Lei; Jiang, Wei

    2010-04-15

    In this work, we developed a novel DNA quantitative analysis based on fluorescence resonance energy transfer (FRET) realized by combination with a surfactant CPB. The approach was capable of detecting long-stranded DNA in a separation-free format. A sandwich-type FAM-c-DNA-t-DNA-r-DNA-TAMRA conjugate was first formed by the capture probe tagged with FAM, the reporter probe tagged with TAMRA and the target DNA through hybridization. The donor (FAM) and the acceptor (TAMRA) were bridged to afford a FRET system. Subsequently, an addition of the cationic surfactant CPB to the system resulted in a substantial change of the microenvironment and an effective condensation of DNA strands. Consequently, without altering the component of the double strands, an enhanced acceptor fluorescence signal from FRET was achieved and a quantification of the target DNA containing 30 bases was enabled. Under the optimal experimental conditions, an excellent linear relationship between the increase of acceptor fluorescent peak area and the target DNA concentration was obtained over the range from 1.0 x 10(-7) to 3.0 x 10(-9) mol L(-1). The proposed approach offered adequate sensitivity for the detection of the target DNA at 1.0 x 10(-9) mol L(-1).

  4. Multiplexed Nucleic Acid Hybridization Assays Using Single-FRET-Pair Distance-Tuning.

    Science.gov (United States)

    Qiu, Xue; Guo, Jiajia; Jin, Zongwen; Petreto, Alexandra; Medintz, Igor L; Hildebrandt, Niko

    2017-07-01

    Multiplexed photoluminescence (PL) detection plays an important role in chemical and biological sensing. Here, it is shown that time-gated (TG) detection of a single terbium-donor-based Förster resonance energy transfer (FRET) pair can be used to selectively quantify low nanomolar concentrations of multiple DNAs or microRNAs in a single sample. This study demonstrates the applicability of single-TG-FRET-pair multiplexing for molecular (Tb-to-dye) and nanoparticle (Tb-to-quantum-dot) biosensing. Both systems use acceptor-sensitization and donor-quenching for quantifying biomolecular recognition and modification of the donor-acceptor distance for tuning the PL decays. TG intensity detection provides extremely low background noise and a quick and simple one-step assay format. Single-TG-FRET-pair multiplexing can be combined with spectral and spatial resolution, paving the way for biosensing with unprecedented high-order multiplexing capabilities. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Recognition and Analysis of Corrosion Failure Mechanisms

    Directory of Open Access Journals (Sweden)

    Steven Suess

    2006-02-01

    Full Text Available Corrosion has a vast impact on the global and domestic economy, and currently incurs losses of nearly $300 billion annually to the U.S. economy alone. Because of the huge impact of corrosion, it is imperative to have a systematic approach to recognizing and mitigating corrosion problems as soon as possible after they become apparent. A proper failure analysis includes collection of pertinent background data and service history, followed by visual inspection, photographic documentation, material evaluation, data review and conclusion procurement. In analyzing corrosion failures, one must recognize the wide range of common corrosion mechanisms. The features of any corrosion failure give strong clues as to the most likely cause of the corrosion. This article details a proven approach to properly determining the root cause of a failure, and includes pictographic illustrations of the most common corrosion mechanisms, including general corrosion, pitting, galvanic corrosion, dealloying, crevice corrosion, microbiologically-influenced corrosion (MIC, corrosion fatigue, stress corrosion cracking (SCC, intergranular corrosion, fretting, erosion corrosion and hydrogen damage.

  6. Influence of Fretting Wear on Fretting Parameters in Press-Fitted Shaft%微动磨损对过盈配合结构微动参量的影响

    Institute of Scientific and Technical Information of China (English)

    张远彬; 鲁连涛; 曾东方; 张继旺

    2015-01-01

    基于Archard磨损模型与Abaqus自适应网格技术建立了仿真分析过盈配合结构微动磨损的计算模型,对配合面轮廓随循环周次的变化进行了预测,并详细研究了微动磨损对接触压应力、摩擦剪切应力及微动滑移幅值等微动参量的影响.结果表明:该计算模型能够较为准确地对配合面轮廓随循环周次的变化进行预测;由于微动磨损的作用,配合边缘处接触压应力的峰值逐渐增大,且其位置逐渐向配合内部移动;摩擦剪切应力的最大值逐渐由黏着-滑移过渡位置向磨损-未磨损过渡位置移动;张开区域的宽度以及滑移区内各位置处的微动滑移幅值均随着循环周次的增加而增大.

  7. REDUCED ENGINE FRICTION AND WEAR

    Energy Technology Data Exchange (ETDEWEB)

    Ron Matthews

    2005-05-01

    This Final Technical Report discusses the progress was made on the experimental and numerical tasks over the duration of this project regarding a new technique for decreasing engine friction and wear via liner rotation. The experimental subtasks involved quantifying the reduction in engine friction for a prototype rotating liner engine relative to a comparable baseline engine. Both engine were single cylinder conversions of nominally identical production four-cylinder engines. Hot motoring tests were conducted initially and revealed that liner rotation decreased engine friction by 20% under motoring conditions. A well-established model was used to estimate that liner rotation should decrease the friction of a four-cylinder engine by 40% under hot motoring conditions. Hot motoring tear-down tests revealed that the crankshaft and valve train frictional losses were essentially the same for the two engines, as expected. However, the rotating liner engine had much lower (>70%) piston assembly friction compared to the conventional engine. Finally, we used the Instantaneous IMEP method to compare the crank-angle resolved piston assembly friction for the two engines. Under hot motoring conditions, these measurements revealed a significant reduction in piston assembly friction, especially in the vicinity of compression TDC when the lubrication regime transitions from hydrodynamic through mixed and into boundary friction. We have some remaining problems with these measurements that we expect to solve during the next few weeks. We will then perform these measurements under firing conditions. We also proposed to improve the state-of-the-art of numerical modeling of piston assembly friction for conventional engines and then to extend this model to rotating liner engines. Our research team first modeled a single ring in the Purdue ring-liner test rig. Our model showed good agreement with the test rig data for a range of speeds and loads. We then modeled a complete piston

  8. Structural transformations in wear resistance of iron- and cobalt-based amorphous alloys during abrasive wear

    Science.gov (United States)

    Korshunov, L. G.; Shabashov, V. A.; Chernenko, N. L.

    2010-04-01

    The wear resistance and structural changes in a number of amorphous alloys based on iron and cobalt and in high-carbon tool steels are studied during wear by a fixed abrasive (crondum, Carborundum) at room temperature and -196°C. The abrasive wear resistance of the amorphous alloys is shown to be 1.6-3.1 lower than that of the high-carbon tool steels having a similar hardness. The relatively low level of the abrasive wear resistance of the amorphous alloys is assumed to be caused by strain softening of their surface during wear. A nanocrystalline structure is found to form in local microvolumes in a thin deformed surface layer of the alloys.

  9. Incisor wear and age in Yellowstone bison

    Science.gov (United States)

    Christianson, D.A.; Gogan, P.J.P.; Podruzny, K.M.; Olexa, E.M.

    2005-01-01

    Biologists commonly use tooth eruption and wear patterns or cementum annuli techniques to estimate age of ungulates. However, in some situations the accuracy or sampling procedures of either approach are undesirable. We investigated the progression of several quantitative measures of wear with age, using permanent first incisors from Yellowstone bison (Bison bison), and tested for differences between sexes and herds. We further investigated the relationship of wear and age to explore an age-estimation method. Labial-lingual width (LLW) correlated best with assigned age (r2=0.66, males; r2=0.76 females). Labial-lingual width differed between sexes, with females showing ∼0.2 mm more wear than males. Additionally, differences in rate of wear existed between bison of the northern and central Yellowstone herds (1.2 and 0.9 mm/year, respectively). We developed a regression formula to test the power of LLW as an estimator of Yellowstone bison age. Our method provided estimated ages within 1 year of the assigned age 73% and 82% of the time for female and male bison, respectively.

  10. Dental Wear: A Scanning Electron Microscope Study

    Directory of Open Access Journals (Sweden)

    Luca Levrini

    2014-01-01

    Full Text Available Dental wear can be differentiated into different types on the basis of morphological and etiological factors. The present research was carried out on twelve extracted human teeth with dental wear (three teeth showing each type of wear: erosion, attrition, abrasion, and abfraction studied by scanning electron microscopy (SEM. The study aimed, through analysis of the macro- and micromorphological features of the lesions (considering the enamel, dentin, enamel prisms, dentinal tubules, and pulp, to clarify the different clinical and diagnostic presentations of dental wear and their possible significance. Our results, which confirm current knowledge, provide a complete overview of the distinctive morphology of each lesion type. It is important to identify the type of dental wear lesion in order to recognize the contributing etiological factors and, consequently, identify other more complex, nondental disorders (such as gastroesophageal reflux, eating disorders. It is clear that each type of lesion has a specific morphology and mechanism, and further clinical studies are needed to clarify the etiological processes, particularly those underlying the onset of abfraction.

  11. Brush seal shaft wear resistant coatings

    Science.gov (United States)

    Howe, Harold

    1995-03-01

    Brush seals suffer from high wear, which reduces their effectiveness. This work sought to reduce brush seal wear by identifying and testing several industry standard coatings. One of the coatings was developed for this work. It was a co-sprayed PSZ with boron-nitride added for a high temperature dry lubricant. Other coatings tested were a PSZ, chrome carbide and a bare rotor. Testing of these coatings included thermal shocking, tensile testing and wear/coefficient of friction testing. Wear testing consisted of applying a coating to a rotor and then running a sample tuft of SiC ceramic fiber against the coating. Surface speeds at point of contact were slightly over 1000 ft/sec. Rotor wear was noted, as well as coefficient of friction data. Results from the testing indicates that the oxide ceramic coatings cannot withstand the given set of conditions. Carbide coatings will not work because of the need for a metallic binder, which oxidizes in the high heat produced by friction. All work indicated a need for a coating that has a lubricant contained within itself and the coating must be resistant to an oxidizing environment.

  12. Impact wear behaviors of Hadfield manganese steel

    Institute of Scientific and Technical Information of China (English)

    FANG Liang; XU Yun-hua; CEN Qi-hong; ZHU Jin-hua

    2005-01-01

    Impact wear behaviors of Hadfield manganese steel at different impact angles were investigated. The results of impact wear tests show that there exists a critical impact load for Hadfield steel. The wear rate suddenly turns down after some impact cycles when the impact load is greater than the critical load. The critical impact load is smaller than 8.2 J in this research because the nano-sized austenitic grains embedded in amorphous delay the crack propagation in subsurface. From high resolution transmission electron microscope (HRTEM) examination of subsurface microstructure, it is found that a large amount of nano-sized grains embedded in bulk amorphous matrix are fully developed and no martensitic transformation occurs during the impact wear process. The analytical results of worn surface morphology and debris indicate that the initiation of crack, propagation and spalling are restricted in the amorphous phase, resulting in the size distribution of debris in nano-sizes, which is the reason why the wear rate of Hadfield steel is greatly decreased at high impact load.

  13. Classic maximum entropy recovery of the average joint distribution of apparent FRET efficiency and fluorescence photons for single-molecule burst measurements.

    Science.gov (United States)

    DeVore, Matthew S; Gull, Stephen F; Johnson, Carey K

    2012-04-05

    We describe a method for analysis of single-molecule Förster resonance energy transfer (FRET) burst measurements using classic maximum entropy. Classic maximum entropy determines the Bayesian inference for the joint probability describing the total fluorescence photons and the apparent FRET efficiency. The method was tested with simulated data and then with DNA labeled with fluorescent dyes. The most probable joint distribution can be marginalized to obtain both the overall distribution of fluorescence photons and the apparent FRET efficiency distribution. This method proves to be ideal for determining the distance distribution of FRET-labeled biomolecules, and it successfully predicts the shape of the recovered distributions.

  14. FRET-Aptamer Assays for Bone Marker Assessment, C-Telopeptide, Creatinine, and Vitamin D

    Science.gov (United States)

    Bruno, John G.

    2013-01-01

    Astronauts lose 1.0 to 1.5% of their bone mass per month on long-duration spaceflights. NASA wishes to monitor the bone loss onboard spacecraft to develop nutritional and exercise countermeasures, and make adjustments during long space missions. On Earth, the same technology could be used to monitor osteoporosis and its therapy. Aptamers bind to targets against which they are developed, much like antibodies. However, aptamers do not require animal hosts or cell culture and are therefore easier, faster, and less expensive to produce. In addition, aptamers sometimes exhibit greater affinity and specificity vs. comparable antibodies. In this work, fluorescent dyes and quenchers were added to the aptamers to enable pushbutton, one-step, bind-and-detect fluorescence resonance energy transfer (FRET) assays or tests that can be freeze-dried, rehydrated with body fluids, and used to quantitate bone loss of vitamin D levels with a handheld fluorometer in the spacecraft environment. This work generated specific, rapid, one-step FRET assays for the bone loss marker C-telopeptide (CTx) when extracted from urine, creatinine from urine, and vitamin D congeners in diluted serum. The assays were quantified in nanograms/mL using a handheld fluorometer connected to a laptop computer to convert the raw fluorescence values into concentrations of each analyte according to linear standard curves. DNA aptamers were selected and amplified for several rounds against a 26- amino acid form of CTx, creatinine, and vitamin D. The commonalities between loop structures were studied, and several common loop structures were converted into aptamer beacons with a fluorophore and quencher on each end. In theory, when the aptamer beacon binds its cognate target (CTx bone peptide, creatinine, or vitamin D), it is forced open and no longer quenched, so it gives off fluorescent light (when excited) in proportion to the amount of target present in a sample. This proportional increase in fluorescence is

  15. FRET Sensor for Erythrosine Dye Based on Organic Nanoparticles: Application to Analysis of Food Stuff.

    Science.gov (United States)

    Mahajan, Prasad G; Bhopate, Dhanaji P; Kolekar, Govind B; Patil, Shivajirao R

    2016-07-01

    An aqueous suspension of fluorescent nanoparticles (PHNNPs) of naphthol based fluorescent organic compound 1-[(Z)-(2-phenylhydrazinylidene) methyl] naphthalene -2-ol (PHN) were prepared using reprecipitation method shows bathochromically shifted aggregation induced enhanced emission (AIEE) in the spectral region where erythrosine (ETS) food dye absorbs strongly. The average size of 72.6 nm of aqueous suspension of PHNNPs obtained by Dynamic light scattering results shows a narrow particle size distribution. The negative zeta potential of nano probe (-22.6 mV) responsible to adsorb oppositely charged analyte on its surface and further permit to bind nano probe and analyte within the close distance proximity required for efficient fluorescence resonance energy transfer (FRET) to take place from donor (PHNNPs) to acceptor (ETS). Systematic FRET experiments performed by measuring fluorescence quenching of PHNNPs with successive addition of ETS solution exploited the use of the PHNNPs as a novel nano probe for the detection of ETS in aqueous solution with extremely lower limit of detection equal to 3.6 nM (3.1 ng/mL). The estimation of photo kinetic and thermodynamic parameters such as quenching rate constant, enthalpy change (∆H), Gibbs free energy change (∆G) and entropy change (∆S) was obtained by the quenching results obtained at different constant temperatures which were found to fit the well-known Stern-Volmer relation. The mechanism of binding and fluorescence quenching of PHNNPs by ETS food dye is proposed on the basis of results obtained in photophysical studies, thermodynamic parameter, energy transfer efficiency, critical energy transfer distance (R0) and distance of approach between donor-acceptor molecules (r). The proposed FRET method based on fluorescence quenching of PHNNPs was successfully applied to develop an analytical method for estimation of ETS from food stuffs without interference of other complex ingredients. Graphical Abstract A

  16. FRET-Based Detection of M1 Muscarinic Acetylcholine Receptor Activation by Orthosteric and Allosteric Agonists

    Science.gov (United States)

    Markovic, Danijela; Holdich, Jonathan; Al-Sabah, Suleiman; Mistry, Rajendra; Krasel, Cornelius; Mahaut-Smith, Martyn P.; Challiss, R. A. John

    2012-01-01

    Background and Objective Muscarinic acetylcholine receptors (mAChRs) are 7-transmembrane, G protein-coupled receptors that regulate a variety of physiological processes and represent potentially important targets for therapeutic intervention. mAChRs can be stimulated by full and partial orthosteric and allosteric agonists, however the relative abilities of such ligands to induce conformational changes in the receptor remain unclear. To gain further insight into the actions of mAChR agonists, we have developed a fluorescently tagged M1 mAChR that reports ligand-induced conformational changes in real-time by changes in Förster resonance energy transfer (FRET). Methods Variants of CFP and YFP were inserted into the third intracellular loop and at the end of the C-terminus of the mouse M1 mAChR, respectively. The optimized FRET receptor construct (M1-cam5) was expressed stably in HEK293 cells. Results The variant CFP/YFP-receptor chimera expressed predominantly at the plasma membrane of HEK293 cells and displayed ligand-binding affinities comparable with those of the wild-type receptor. It also retained an ability to interact with Gαq/11 proteins and to stimulate phosphoinositide turnover, ERK1/2 phosphorylation and undergo agonist-dependent internalization. Addition of the full agonist methacholine caused a reversible decrease in M1 FRET (FEYFP/FECFP) that was prevented by atropine pre-addition and showed concentration-dependent amplitude and kinetics. Partial orthosteric agonists, arecoline and pilocarpine, as well as allosteric agonists, AC-42 and 77-LH-28-1, also caused atropine-sensitive decreases in the FRET signal, which were smaller in amplitude and significantly slower in onset compared to those evoked by methacholine. Conclusion The M1 FRET-based receptor chimera reports that allosteric and orthosteric agonists induce similar conformational changes in the third intracellular loop and/or C-terminus, and should prove to be a valuable molecular reagent for

  17. FRET-based detection of M1 muscarinic acetylcholine receptor activation by orthosteric and allosteric agonists.

    Directory of Open Access Journals (Sweden)

    Danijela Markovic

    Full Text Available BACKGROUND AND OBJECTIVE: Muscarinic acetylcholine receptors (mAChRs are 7-transmembrane, G protein-coupled receptors that regulate a variety of physiological processes and represent potentially important targets for therapeutic intervention. mAChRs can be stimulated by full and partial orthosteric and allosteric agonists, however the relative abilities of such ligands to induce conformational changes in the receptor remain unclear. To gain further insight into the actions of mAChR agonists, we have developed a fluorescently tagged M(1 mAChR that reports ligand-induced conformational changes in real-time by changes in Förster resonance energy transfer (FRET. METHODS: Variants of CFP and YFP were inserted into the third intracellular loop and at the end of the C-terminus of the mouse M(1 mAChR, respectively. The optimized FRET receptor construct (M(1-cam5 was expressed stably in HEK293 cells. RESULTS: The variant CFP/YFP-receptor chimera expressed predominantly at the plasma membrane of HEK293 cells and displayed ligand-binding affinities comparable with those of the wild-type receptor. It also retained an ability to interact with Gα(q/11 proteins and to stimulate phosphoinositide turnover, ERK1/2 phosphorylation and undergo agonist-dependent internalization. Addition of the full agonist methacholine caused a reversible decrease in M(1 FRET (F(EYFP/F(ECFP that was prevented by atropine pre-addition and showed concentration-dependent amplitude and kinetics. Partial orthosteric agonists, arecoline and pilocarpine, as well as allosteric agonists, AC-42 and 77-LH-28-1, also caused atropine-sensitive decreases in the FRET signal, which were smaller in amplitude and significantly slower in onset compared to those evoked by methacholine. CONCLUSION: The M(1 FRET-based receptor chimera reports that allosteric and orthosteric agonists induce similar conformational changes in the third intracellular loop and/or C-terminus, and should prove to be a

  18. [Wear and different restorative materials--a review].

    Science.gov (United States)

    Beyth, N; Sharon, E; Lipovetsky, M; Smidt, A

    2006-07-01

    Wear of materials is a complex and unpredictable phenomenon. The variables affecting the mechanism of wear include the properties of the two contacting materials and the surrounding and interfacial media. This paper reviews the dental wear of different restorative materials and their counter effect on the tooth structure. It presents the updated classifications for tooth surface lesions termed dental wear, and discusses the wear behavior of various restorative materials. Some guidelines for restorative material selection are given. Clinical wear bears a multifactorial etiology, understanding the mechanism of action is an important step in an appropriate restoration material selection. Each material selected should meet the individual wear behavior and needs. Individual factors may enhance the wear rates: aggressive tooth brushing, parafunctions, diet, acidic/aqueous environment, surface geometry, and diminished tooth support. Supportive treatment following restoration is important to monitor wear rates.

  19. Heart failure

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    2008275 Relationship of calcineure in mRNA level in peripheral blood and cardiac muscle of patients with heart failure.WANG Mengmeng(王萌萌),et al.Dept Cardiol,Shandong Prov Hosp,Shandong Univ,Jinan 250021.Chin Cir J 2008;23(2):113-116.Objective To study the relationship of calcineurin mRNA level between peripheral lymphocytes and cardiac muscles of patients with chronic heart failure.Methods

  20. Heart failure

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    2008037 Factors associated with efficacy of cardiac resynchronization therapy for patients with congestive heart failure. SHI Haoying(史浩颖), et al. Dept Cardiol, Zhongshan Hosp Fudan Univ, Shanghai 200032. Chin J Cardiol 2007;35(12):1099-1163. Objective The efficacy of cardiac resynchronization therapy (CRT) in patients with congestive heart failure and the potential factors associated with responder or nonresponder were investigated. Methods Fifty

  1. Anti-Wear Performance and Mechanism of an Oil-Miscible Ionic Liquid as a Lubricant Additive

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Jun [ORNL; Bansal, Dinesh G [ORNL; Yu, Bo [ORNL; Howe, Jane Y [ORNL; Luo, Huimin [ORNL; Dai, Sheng [ORNL; Li, Huaqing [ORNL; Blau, Peter Julian [ORNL; Bunting, Bruce G [ORNL; Mordukhovich, Gregory [GM R& D and Planning, Warren, Michigan; Smolenski, Donald [GM R& D and Planning, Warren, Michigan

    2012-01-01

    An ionic liquid (IL) trihexyltetradecylphosphonium bis(2-ethylhexyl) phosphate has been investigated as a potential anti-wear lubricant additive. Unlike most other ILs that have very low solubility in non-polar fluids, this IL is fully miscible with various hydrocarbon oils. In addition, it is thermally stable up to 347 oC, showed no corrosive attack to cast iron in ambient environment, and has excellent wettability on solid surfaces (e.g., contact angle on cast iron <8o). Most importantly, this phosphonium-based IL has demonstrated effective anti-scuffing and anti-wear characteristics when blended with lubricating oils. For example, a 5 wt.% addition into a synthetic base oil eliminated the scuffing failure experienced by the neat oil and, as a result, reduced the friction coefficient by 60% and the wear rate by three orders of magnitude. A synergistic effect on wear protection was observed with the current anti-wear additive when added into a fully-formulated engine oil. Nanostructure examination and composition analysis revealed a tribo-boundary film and subsurface plastic deformation zone for the metallic surface lubricated by the IL-containing lubricants. This protective boundary film is believed to be responsible for the IL s anti-scuffing and anti-wear functionality.

  2. CR TKA UHMWPE Wear Tested after Artificial Aging of the Vitamin E Treated Gliding Component by Simulating Daily Patient Activities

    Directory of Open Access Journals (Sweden)

    Jens Schwiesau

    2014-01-01

    Full Text Available The wear behaviour of total knee arthroplasty (TKA is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE cruciate retaining (CR total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62±0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.

  3. Tribology of Si/SiO2 in humid air: transition from severe chemical wear to wearless behavior at nanoscale.

    Science.gov (United States)

    Chen, Lei; He, Hongtu; Wang, Xiaodong; Kim, Seong H; Qian, Linmao

    2015-01-13

    Wear at sliding interfaces of silicon is a main cause for material loss in nanomanufacturing and device failure in microelectromechanical system (MEMS) applications. However, a comprehensive understanding of the nanoscale wear mechanisms of silicon in ambient conditions is still lacking. Here, we report the chemical wear of single crystalline silicon, a material used for micro/nanoscale devices, in humid air under the contact pressure lower than the material hardness. A transmission electron microscopy (TEM) analysis of the wear track confirmed that the wear of silicon in humid conditions originates from surface reactions without significant subsurface damages such as plastic deformation or fracture. When rubbed with a SiO2 ball, the single crystalline silicon surface exhibited transitions from severe wear in intermediate humidity to nearly wearless states at two opposite extremes: (a) low humidity and high sliding speed conditions and (b) high humidity and low speed conditions. These transitions suggested that at the sliding interfaces of Si/SiO2 at least two different tribochemical reactions play important roles. One would be the formation of a strong "hydrogen bonding bridge" between hydroxyl groups of two sliding interfaces and the other the removal of hydroxyl groups from the SiO2 surface. The experimental data indicated that the dominance of each reaction varies with the ambient humidity and sliding speed.

  4. CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

    Science.gov (United States)

    Schwiesau, Jens; Fritz, Bernhard; Kutzner, Ines; Bergmann, Georg; Grupp, Thomas M

    2014-01-01

    The wear behaviour of total knee arthroplasty (TKA) is dominated by two wear mechanisms: the abrasive wear and the delamination of the gliding components, where the second is strongly linked to aging processes and stress concentration in the material. The addition of vitamin E to the bulk material is a potential way to reduce the aging processes. This study evaluates the wear behaviour and delamination susceptibility of the gliding components of a vitamin E blended, ultra-high molecular weight polyethylene (UHMWPE) cruciate retaining (CR) total knee arthroplasty. Daily activities such as level walking, ascending and descending stairs, bending of the knee, and sitting and rising from a chair were simulated with a data set received from an instrumented knee prosthesis. After 5 million test cycles no structural failure of the gliding components was observed. The wear rate was with 5.62 ± 0.53 mg/million cycles falling within the limit of previous reports for established wear test methods.

  5. Resolution of Two Sub-Populations of Conformers and Their Individual Dynamics by Time Resolved Ensemble Level FRET Measurements.

    Directory of Open Access Journals (Sweden)

    Gil Rahamim

    Full Text Available Most active biopolymers are dynamic structures; thus, ensembles of such molecules should be characterized by distributions of intra- or intermolecular distances and their fast fluctuations. A method of choice to determine intramolecular distances is based on Förster resonance energy transfer (FRET measurements. Major advances in such measurements were achieved by single molecule FRET measurements. Here, we show that by global analysis of the decay of the emission of both the donor and the acceptor it is also possible to resolve two sub-populations in a mixture of two ensembles of biopolymers by time resolved FRET (trFRET measurements at the ensemble level. We show that two individual intramolecular distance distributions can be determined and characterized in terms of their individual means, full width at half maximum (FWHM, and two corresponding diffusion coefficients which reflect the rates of fast ns fluctuations within each sub-population. An important advantage of the ensemble level trFRET measurements is the ability to use low molecular weight small-sized probes and to determine nanosecond fluctuations of the distance between the probes. The limits of the possible resolution were first tested by simulation and then by preparation of mixtures of two model peptides. The first labeled polypeptide was a relatively rigid Pro7 and the second polypeptide was a flexible molecule consisting of (Gly-Ser7 repeats. The end to end distance distributions and the diffusion coefficients of each peptide were determined. Global analysis of trFRET measurements of a series of mixtures of polypeptides recovered two end-to-end distance distributions and associated intramolecular diffusion coefficients, which were very close to those determined from each of the pure samples. This study is a proof of concept study demonstrating the power of ensemble level trFRET based methods in resolution of subpopulations in ensembles of flexible macromolecules.

  6. Wear Resistant Amorphous and Nanocomposite Coatings

    Energy Technology Data Exchange (ETDEWEB)

    Racek, O

    2008-03-26

    Glass forming materials (critical cooling rate <10{sup 4}K.s{sup -1}) are promising for their high corrosion and wear resistance. During rapid cooling, the materials form an amorphous structure that transforms to nanocrystalline during a process of devitrification. High hardness (HV 1690) can be achieved through a controlled crystallization. Thermal spray process has been used to apply coatings, which preserves the amorphous/nanocomposite structure due to a high cooling rate of the feedstock particles during the impact on a substrate. Wear properties have been studied with respect to process conditions and feedstock material properties. Application specific properties such as sliding wear resistance have been correlated with laboratory tests based on instrumented indentation and scratch tests.

  7. Modelling the failure behaviour of wind turbines

    Science.gov (United States)

    Faulstich, S.; Berkhout, V.; Mayer, J.; Siebenlist, D.

    2016-09-01

    Modelling the failure behaviour of wind turbines is an essential part of offshore wind farm simulation software as it leads to optimized decision making when specifying the necessary resources for the operation and maintenance of wind farms. In order to optimize O&M strategies, a thorough understanding of a wind turbine's failure behaviour is vital and is therefore being developed at Fraunhofer IWES. Within this article, first the failure models of existing offshore O&M tools are presented to show the state of the art and strengths and weaknesses of the respective models are briefly discussed. Then a conceptual framework for modelling different failure mechanisms of wind turbines is being presented. This framework takes into account the different wind turbine subsystems and structures as well as the failure modes of a component by applying several influencing factors representing wear and break failure mechanisms. A failure function is being set up for the rotor blade as exemplary component and simulation results have been compared to a constant failure rate and to empirical wind turbine fleet data as a reference. The comparison and the breakdown of specific failure categories demonstrate the overall plausibility of the model.

  8. The Delamination Theory of Wear - III

    Science.gov (United States)

    1977-12-01

    117. 18 A. P. Orson , J. Mach. Phys. Solids, 2 (1954) 197 - 211, 19 D. R. Wheeler and D, H. Buckley, Wear, 83 (1975) 65. 20 V. C, Scott end H. Wilman...papers were also published In Volume 44 no. I of the Journal Wear, edited by1). Scott . "ELSEVIER SEQUOIA S.A., LAUSANNE, 1977 APproved for public ioleoee...possible without the enthusiasm and support of Messrs. Douglas Scott and VOrnon C, Westoott. This kind of research cannot reodily be undertaken at a

  9. Consideration of wear rates at high velocity

    Science.gov (United States)

    Hale, Chad S.

    The development of the research presented here is one in which high velocity relative sliding motion between two bodies in contact has been considered. Overall, the wear environment is truly three-dimensional. The attempt to characterize three-dimensional wear was not economically feasible because it must be analyzed at the micro-mechanical level to get results. Thus, an engineering approximation was carried out. This approximation was based on a metallographic study identifying the need to include viscoplasticity constitutive material models, coefficient of friction, relationships between the normal load and velocity, and the need to understand wave propagation. A sled test run at the Holloman High Speed Test Track (HHSTT) was considered for the determination of high velocity wear rates. In order to adequately characterize high velocity wear, it was necessary to formulate a numerical model that contained all of the physical events present. The experimental results of a VascoMax 300 maraging steel slipper sliding on an AISI 1080 steel rail during a January 2008 sled test mission were analyzed. During this rocket sled test, the slipper traveled 5,816 meters in 8.14 seconds and reached a maximum velocity of 1,530 m/s. This type of environment was never considered previously in terms of wear evaluation. Each of the features of the metallography were obtained through micro-mechanical experimental techniques. The byproduct of this analysis is that it is now possible to formulate a model that contains viscoplasticity, asperity collisions, temperature and frictional features. Based on the observations of the metallographic analysis, these necessary features have been included in the numerical model, which makes use of a time-dynamic program which follows the movement of a slipper during its experimental test run. The resulting velocity and pressure functions of time have been implemented in the explicit finite element code, ABAQUS. Two-dimensional, plane strain models

  10. Wear Analysis of Wind Turbine Gearbox Bearings

    Energy Technology Data Exchange (ETDEWEB)

    Blau, Peter Julian [ORNL; Walker, Larry R [ORNL; Xu, Hanbing [ORNL; Parten, Randy J [ORNL; Qu, Jun [ORNL; Geer, Tom [ORNL

    2010-04-01

    The objective of this effort was to investigate and characterize the nature of surface damage and wear to wind turbine gearbox bearings returned from service in the field. Bearings were supplied for examination by S. Butterfield and J. Johnson of the National Wind Technology Center (NREL), Boulder, Colorado. Studies consisted of visual examination, optical and electron microscopy, dimensional measurements of wear-induced macro-scale and micro-scale features, measurements of macro- and micro-scale hardness, 3D imaging of surface damage, studies of elemental distributions on fracture surfaces, and examinations of polished cross-sections of surfaces under various etched and non-etched conditions.

  11. Gradient Index in Wear Debris Image Collection

    Institute of Scientific and Technical Information of China (English)

    LVZhi-yong; GAOHui-liang; YANXin-ping

    2004-01-01

    In order to solve a problem of oil on-line monitoring, this instrument adopts a prinripium of self-focus lens of Gradieat index fiber( GRIN Len) to design optics system and magnetic circuit. For the magnetic circuit, the monitor can catch particle wear debris in oil. And for the optics circuit. GRIN Len can transfer image of debris to apparatus of gather image, e . g, CCD and camera. And the image of debris is transferred to computer for analyzing seize and physiognomy of debris. The character of the monitor is of micro weight, micro volume andcurve imaging And it is directly pluged into oil to catch image of wear particles.

  12. Surface engineering for enhanced performance against wear

    CERN Document Server

    2013-01-01

    Surface Engineering constitutes a variety of processes and sub processes. Each chapter of this work covers specific processes by experts working in the area. Included for each topic are tribological performances for each process as well as results of recent research. The reader also will benefit from in-depth studies of diffusion coatings, nanocomposite films for wear resistance, surfaces for biotribological applications, thin-film wear, tribology of thermal sprayed coatings, hardfacing, plating for tribology and high energy beam surface modifications. Material scientists as well as engineers working with surface engineering for tribology will be particularly interested in this work.

  13. Investigations of the effects of particle properties on the wear resistance of the particle reinforced composites using a novel wear model

    Science.gov (United States)

    Prabhu, T. Ram

    2016-08-01

    A wear model is developed based on the discrete lattice spring-mass approach to study the effects of particle volume fraction, size, and stiffness on the wear resistance of particle reinforced composites. To study these effects, we have considered three volume fractions (10%, 20% and 30%), two sizes (10 × 10 and 4 × 4 sites), and two different stiffness of particles embedded in the matrix in a regular pattern. In this model, we have discretized the composite system (400 × 100 sites) into the lumped masses connected with interaction spring elements in two dimensions. The interaction elements are assumed as linear elastic and ideal plastic under applied forces. Each mass is connected to its first and second nearest neighbors by springs. The matrix and particles sites are differentiated by choosing the different stiffness values. The counter surface is simulated as a rigid body that moves on the composite material at a constant sliding speed along the horizontal direction. The governing equations are formed by equating the spring force between the pair of sites given by Hooke’s law plus external contact forces and the force due to the motion of the site given by the equation of motion. The equations are solved for the plastic strain accumulated in the springs using an explicit time stepping procedure based on a finite difference form of the above equations. If the total strain accumulated in the spring elements connected to a lump mass site exceeds the failure strain, the springs are considered to be broken, and the mass site is removed or worn away from the lattice and accounts as a wear loss. The model predicts that (i) increasing volume fraction, reducing particle size and increasing particle stiffness enhance the wear resistance of the particle reinforced composites, (ii) the particle stiffness is the most significant factor affecting the wear resistance of the composites, and (iii) the wear resistance reduced above the critical volume fraction (Vc), and Vc

  14. Development of wear resistant nanostructured duplex coatings by high velocity oxy-fuel process for use in oil sands industry.

    Science.gov (United States)

    Saha, Gobinda C; Khan, Tahir I; Glenesk, Larry B

    2009-07-01

    Oil sands deposits in Northern Alberta, Canada represent a wealth of resources attracting huge capital investment and significant research focus in recent years. As of 2005, crude oil production from the current oil sands operators accounted for 50% of Canada's domestic production. Alberta's oil sands deposits contain approximately 1.7 trillion barrels of bitumen, of which over 175 billion are recoverable with current technology, and 315 billion barrels are ultimately recoverable with technological advances. A major problem of operating machinery and equipment in the oil sands is the unpredictable failure from operating in this highly aggressive environment. One of the significant causes of that problem is premature material wear. An approach to minimize this wear is the use of protective coatings and, in particular, a cermet thin coating. A high level of coating homogeneity is critical for components such as bucketwheels, draglines, conveyors, shovels, heavyhauler trucks etc. that are subjected to severe degradation through abrasive wear. The identification, development and application of optimum wear solutions for these components pose an ongoing challenge. Nanostructured cermet coatings have shown the best results of achieving the degree of homogeneity required for these applications. In this study, WC-17Co cermet powder with nanocrystalline WC core encapsulated with 'duplex' Co layer was used to obtain a nanostructured coating. To apply this coating, high velocity oxy-fuel (HVOF) thermal spraying technique was used, as it is known for producing wear-resistant coatings superior to those obtained from plasma-based techniques. Mechanical, sliding wear and microstructural behavior of the coating was compared with those of the microstructured coating obtained from spraying WC-10Co-4Cr cermet powder by HVOF technique. Results from the nanostructured coating, among others, showed an average of 25% increase in microhardness, 30% increase in sliding wear resistance and

  15. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Denkena Berend

    2010-06-01

    Full Text Available Abstract Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in

  16. School failure.

    Science.gov (United States)

    Dworkin, P H

    1989-04-01

    Numerous factors may contribute to a child's failure to learn. Certain causes of school failure, such as specific learning disabilities, mental retardation, sensory impairment, and chronic illness may be regarded as intrinsic characteristics of the child. Other causes, such as family dysfunction, social problems, and ineffective schooling, are characteristics of the child's environment. Still other influences on school performance, such as temperamental dysfunction, attention deficits, and emotional illness, may be viewed as the consequence of the interaction between the child and his or her environment. The reasons for a child's school failure must not be considered in isolation but rather within the context of social and environmental circumstances. Evaluation must consider the myriad of reasons for a child's school failure and attempt to identify "clusters" of adverse influences on school performance. Detailed information must be sought from the student, parents, and school system through the history and physical examination. Questionnaires are useful in data gathering. Ancillary methods of assessment that may be of value include neurodevelopmental screening and laboratory studies. Further investigations and referrals, particularly psychoeducational evaluation, are of major importance. Traditional roles of the pediatrician in school failure include the treatment of underlying medical conditions, counseling, the coordination of further investigations and referrals, and the facilitation of communication with community services and resources. Participation with other disciplines in the development of a child's educational plan is feasible and useful.

  17. Proposal of a New Method for Measuring Förster Resonance Energy Transfer (FRET Rapidly, Quantitatively and Non-Destructively

    Directory of Open Access Journals (Sweden)

    Paul Johannes Helm

    2012-09-01

    Full Text Available The process of radiationless energy transfer from a chromophore in an excited electronic state (the “donor” to another chromophore (an “acceptor”, in which the energy released by the donor effects an electronic transition, is known as “Förster Resonance Energy Transfer” (FRET. The rate of energy transfer is dependent on the sixth power of the distance between donor and acceptor. Determining FRET efficiencies is tantamount to measuring distances between molecules. A new method is proposed for determining FRET efficiencies rapidly, quantitatively, and non-destructively on ensembles containing donor acceptor pairs: at wavelengths suitable for mutually exclusive excitations of donors and acceptors, two laser beams are intensity-modulated in rectangular patterns at duty cycle ½ and frequencies ƒ1 and ƒ2 by electro-optic modulators. In an ensemble exposed to these laser beams, the donor excitation is modulated at ƒ1, and the acceptor excitation, and therefore the degree of saturation of the excited electronic state of the acceptors, is modulated at ƒ2. Since the ensemble contains donor acceptor pairs engaged in FRET, the released donor fluorescence is modulated not only at ƒ1 but also at the beat frequency Δƒ: = |ƒ1 − ƒ2|. The depth of the latter modulation, detectable via a lock-in amplifier, quantitatively indicates the FRET efficiency.

  18. A graphene quantum dot-based FRET system for nuclear-targeted and real-time monitoring of drug delivery.

    Science.gov (United States)

    Chen, Hui; Wang, Zhuyuan; Zong, Shenfei; Chen, Peng; Zhu, Dan; Wu, Lei; Cui, Yiping

    2015-10-07

    A graphene quantum dot-based FRET system is demonstrated for nuclear-targeted drug delivery, which allows for real-time monitoring of the drug release process through FRET signals. In such a system, graphene quantum dots (GQDs) simultaneously serve as the carriers of drugs and donors of FRET pairs. Additionally, a peptide TAT as the nuclear localization signal is conjugated to GQDs, which facilitates the transportation of the delivery system to the nucleus. We have demonstrated that: (a) both the conjugated TAT and small size of GQDs contribute to targeting the nucleus, which results in a significantly enhanced intranuclear accumulation of drugs; (b) FRET signals being extremely sensitive to the distance between donors and acceptors are capable of real-time monitoring of the separation process of drugs and GQDs, which is more versatile in tracking the drug release dynamics. Our strategy for the assembly of a FRET-based drug delivery system may be unique and universal for monitoring the dynamic release process. This study may give more exciting new opportunities for improving the therapeutic efficacy and tracking precision.

  19. Development of a Fluorescence Resonance Energy Transfer (FRET-Based DNA Biosensor for Detection of Synthetic Oligonucleotide of Ganoderma boninense

    Directory of Open Access Journals (Sweden)

    Noremylia Mohd Bakhori

    2013-12-01

    Full Text Available An optical DNA biosensor based on fluorescence resonance energy transfer (FRET utilizing synthesized quantum dot (QD has been developed for the detection of specific-sequence of DNA for Ganoderma boninense, an oil palm pathogen. Modified QD that contained carboxylic groups was conjugated with a single-stranded DNA probe (ssDNA via amide-linkage. Hybridization of the target DNA with conjugated QD-ssDNA and reporter probe labeled with Cy5 allows for the detection of related synthetic DNA sequence of Ganoderma boninense gene based on FRET signals. Detection of FRET emission before and after hybridization was confirmed through the capability of the system to produce FRET at 680 nm for hybridized sandwich with complementary target DNA. No FRET emission was observed for non-complementary system. Hybridization time, temperature and effect of different concentration of target DNA were studied in order to optimize the developed system. The developed biosensor has shown high sensitivity with detection limit of 3.55 × 10−9 M. TEM results show that the particle size of QD varies in the range between 5 to 8 nm after ligand modification and conjugation with ssDNA. This approach is capable of providing a simple, rapid and sensitive method for detection of related synthetic DNA sequence of Ganoderma boninense.

  20. Studying Z-DNA and B- to Z-DNA transitions using a cytosine analogue FRET-pair.

    Science.gov (United States)

    Dumat, Blaise; Larsen, Anders Foller; Wilhelmsson, L Marcus

    2016-06-20

    Herein, we report on the use of a tricyclic cytosine FRET pair, incorporated into DNA with different base pair separations, to study Z-DNA and B-Z DNA junctions. With its position inside the DNA structure, the FRET pair responds to a B- to Z-DNA transition with a distinct change in FRET efficiency for each donor/acceptor configuration allowing reliable structural probing. Moreover, we show how fluorescence spectroscopy and our cytosine analogues can be used to determine rate constants for the B- to Z-DNA transition mechanism. The modified cytosines have little influence on the transition and the FRET pair is thus an easily implemented and virtually non-perturbing fluorescence tool to study Z-DNA. This nucleobase analogue FRET pair represents a valuable addition to the limited number of fluorescence methods available to study Z-DNA and we suggest it will facilitate, for example, deciphering the B- to Z-DNA transition mechanism and investigating the interaction of DNA with Z-DNA binding proteins.

  1. Characterizing the interactions between prolyl isomerase pin1 and phosphatase inhibitor-2 in living cells with FRET and FCS

    Science.gov (United States)

    Sun, Yuansheng; Wang, Lifu; Jyothikumar, Vinod; Brautigan, David L.; Periasamy, Ammasi

    2012-03-01

    Phosphatase inhibitor-2 (I2) was discovered as a regulator of protein Ser/Thr phosphatase-1 and is conserved from yeast to human. Binding between purified recombinant I2 from different species and the prolyl isomerase Pin1 has been demonstrated with pull-down assays, size exclusion chromatography and nuclear magnetic resonance spectroscopy. Despite this, questions persist as to whether these proteins associate together in living cells. In this study, we prepared fluorescent protein (FP) fusions of I2 and Pin1 and employed both Förster Resonance Energy Transfer (FRET) and Fluorescence Correlation Spectroscopy (FCS) imaging techniques to characterize their interactions in living cells. In both intensity-based and time-resolved FRET studies, we observed FRET uniformly across whole cells co-expressing I2-Cerulean and Pin1-Venus that was significantly higher than in negative controls expressing Cerulean FP (without fusing to I2) as the FRET donor and Pin1-Venus, showing a specific interaction between I2-Cerulean and Pin1-Venus in living cells. We also observed the co-diffusion of I2-Cerulean and Pin1-mCherry in Fluorescence Cross Correlation Spectroscopy (FCCS) measurements. We further showed that I2 itself as well as I2-Pin1 formed complexes in living cells (predicted from in vitro studies) via a quantitative FRET assay, and demonstrated from FCS measurements that both I2 and Pin1 (fused to Cerulean) are highly mobile in living cells.

  2. A Quantitative Theoretical Framework For Protein-Induced Fluorescence Enhancement-Förster-Type Resonance Energy Transfer (PIFE-FRET).

    Science.gov (United States)

    Lerner, Eitan; Ploetz, Evelyn; Hohlbein, Johannes; Cordes, Thorben; Weiss, Shimon

    2016-07-01

    Single-molecule, protein-induced fluorescence enhancement (PIFE) serves as a molecular ruler at molecular distances inaccessible to other spectroscopic rulers such as Förster-type resonance energy transfer (FRET) or photoinduced electron transfer. In order to provide two simultaneous measurements of two distances on different molecular length scales for the analysis of macromolecular complexes, we and others recently combined measurements of PIFE and FRET (PIFE-FRET) on the single molecule level. PIFE relies on steric hindrance of the fluorophore Cy3, which is covalently attached to a biomolecule of interest, to rotate out of an excited-state trans isomer to the cis isomer through a 90° intermediate. In this work, we provide a theoretical framework that accounts for relevant photophysical and kinetic parameters of PIFE-FRET, show how this framework allows the extraction of the fold-decrease in isomerization mobility from experimental data, and show how these results provide information on changes in the accessible volume of Cy3. The utility of this model is then demonstrated for experimental results on PIFE-FRET measurement of different protein-DNA interactions. The proposed model and extracted parameters could serve as a benchmark to allow quantitative comparison of PIFE effects in different biological systems.

  3. An effective sensor for tool wear monitoring in face milling: Acoustic emission

    Indian Academy of Sciences (India)

    M T Mathew; P Srinivasa Pai; L A Rocha

    2008-06-01

    Acoustic Emission (AE) has been widely used for monitoring manufacturing processes particularly those involving metal cutting. Monitoring the condition of the cutting tool in the machining process is very important since tool condition will affect the part size, quality and an unexpected tool failure may damage the tool, work-piece and sometimes the machine tool itself. AE can be effectively used for tool condition monitoring applications because the emissions from process changes like tool wear, chip formation i.e. plastic deformation, etc. can be directly related to the mechanics of the process. Also AE can very effectively respond to changes like tool fracture, tool chipping, etc. when compared to cutting force and since the frequency range is much higher than that of machine vibrations and environmental noises, a relatively uncontaminated signal can be obtained. AE signal analysis was applied for sensing tool wear in face milling operations. Cutting tests were carried out on a vertical milling machine. Tests were carried out for a given cutting condition, using single insert, two inserts (adjacent and opposite) and three inserts in the cutter. AE signal parameters like ring down count and rms voltage were measured and were correlated with flank wear values (VB max). The results of this investigation indicate that AE can be effectively used for monitoring tool wear in face milling operations.

  4. Wear and mechanical properties of nano-silica-fused whisker composites.

    Science.gov (United States)

    Xu, H H K; Quinn, J B; Giuseppetti, A A

    2004-12-01

    Resin composites must be improved if they are to overcome the high failure rates in large stress-bearing posterior restorations. This study aimed to improve wear resistance via nano-silica-fused whiskers. It was hypothesized that nano-silica-fused whiskers would significantly improve composite mechanical properties and wear resistance. Nano-silicas were fused onto whiskers and incorporated into a resin at mass fractions of 0%-74%. Fracture toughness (mean +/- SD; n = 6) was 2.92 +/- 0.14 MPa.m(1/2) for whisker composite with 74% fillers, higher than 1.13 +/- 0.19 MPa.m(1/2) for a prosthetic control, and 0.95 +/- 0.11 MPa.m(1/2) for an inlay/onlay control (Tukey's at 0.95). A whisker composite with 74% fillers had a wear depth of 77.7 +/- 6.9 mum, less than 118.0 +/- 23.8 microm of an inlay/onlay control, and 172.5 +/- 15.4 microm of a prosthetic control (p hardness, modulus, strength, and toughness, with R = 0.95-0.97. Novel nano-silica-fused whisker composites possessed high toughness and wear resistance with smooth worn surfaces, and may be useful in large stress-bearing restorations.

  5. Wear behaviour of laser melted an ion implanted materials.

    NARCIS (Netherlands)

    Beurs, Hans de

    1988-01-01

    The emphasis in this thesis is on the development of wear resistant materials by laser melting. Furthermore, the principle aim is to search for the dislocation characteristics common to the wear process in heterogeneous materials. ... Zie: Summary

  6. Comparison of two measurement techniques for clinical wear

    DEFF Research Database (Denmark)

    Peters, M C; Delong, R; Pintado, M R

    1999-01-01

    Clinical wear of restorations is generally evaluated by marginal integrity over time. In this study, both a subjective and an objective method for wear assessment are compared, and the relative advantages and disadvantages of each are considered....

  7. Interactions between nonlinear spur gear dynamics and surface wear

    Science.gov (United States)

    Ding, Huali; Kahraman, Ahmet

    2007-11-01

    In this study, two different dynamic models, a finite elements-based deformable-body model and a simplified discrete model, and a surface wear model are combined to study the interaction between gear surface wear and gear dynamic response. The proposed dynamic gear wear model includes the influence of worn surface profiles on dynamic tooth forces and transmission error as well as the influence of dynamic tooth forces on wear profiles. This paper first introduces the nonlinear dynamic models that include gear backlash and time-varying gear mesh stiffness, and a wear model separately. It presents a comparison to experiments for validation of the dynamic models. The dynamic models are combined with the wear model to study the interaction of surface wear and dynamic behavior in both linear and nonlinear response regimes. At the end, several sets of simulation results are used to demonstrate the two-way relationship between nonlinear gear dynamics and surface wear.

  8. ERRATUM: Work smart, wear your hard hat

    CERN Multimedia

    2003-01-01

    An error appeared in the article «Work smart, wear your hard hat» published in Weekly Bulletin 27/2003, page 5. The impact which pierced a hole in the hard hat worn by Gerd Fetchenhauer was the equivalent of a box weighing 5 kg and not 50 kg.

  9. Reciprocating wear in a steam environment

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L.J.; Gee, M.G. [National Physical Laboratory, Teddington, Middlesex (United Kingdom)

    2010-07-01

    Tests to simulate the wear between sliding components in steam power plant have been performed using a low frequency wear apparatus at elevated temperatures under static load, at ambient pressure, in a steam environment. The apparatus was modified to accept a novel method of steam delivery. The materials tested were pre-exposed in a flowing steam furnace at temperature for either 500 or 3000 hours to provide some simulation of long term ageing. The duration of each wear test was 50 hours and tests were also performed on as-received material for comparison purposes. Data has been compared with results of tests performed on non-oxidised material for longer durations and also on tests without steam to examine the effect of different environments. Data collected from each test consists of mass change, stub height measurement and friction coefficient as well as visual inspection of the wear track. Within this paper, it is reported that both pre-ageing and the addition of steam during testing clearly influence the friction between material surfaces. (orig.)

  10. Saliva parameters and erosive wear in adolescents

    NARCIS (Netherlands)

    Zwier, N.; Huysmans, M.C.D.N.J.M.; Jager, D.H.J.; Ruben, J.; Bronkhorst, E.M.; Truin, G.J.

    2013-01-01

    The aim of this study was to investigate the relationship between several parameters of saliva and erosive wear in adolescents. (Un-)stimulated saliva was collected from 88 adolescents with erosion and 49 controls (age 16 ± 1 years). Flow rate, pH and buffer capacity were determined immediately.

  11. Saliva Parameters and Erosive Wear in Adolescents

    NARCIS (Netherlands)

    Zwier, N.; Huysmans, M. C. D. N. J. M.; Jager, D. H. J.; Ruben, J.; Bronkhorst, E. M.; Truin, G. J.

    2013-01-01

    The aim of this study was to investigate the relationship between several parameters of saliva and erosive wear in adolescents. (Un-)stimulated saliva was collected from 88 adolescents with erosion and 49 controls (age 16 +/- 1 years). Flow rate, pH and buffer capacity were determined immediately.

  12. Healthy Contact Lens Wear and Care

    Centers for Disease Control (CDC) Podcasts

    2014-02-04

    In this podcast, CDC’s Dr. Jennifer Cope explains some basic steps for proper wear and care of soft contact lenses.  Created: 2/4/2014 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 2/4/2014.

  13. Friction and wear of human hair fibres

    Science.gov (United States)

    Bowen, James; Johnson, Simon A.; Avery, Andrew R.; Adams, Michael J.

    2016-06-01

    An experimental study of the tribological properties of hair fibres is reported, and the effect of surface treatment on the evolution of friction and wear during sliding. Specifically, orthogonally crossed fibre/fibre contacts under a compressive normal load over a series of 10 000 cycle studies are investigated. Reciprocating sliding at a velocity of 0.4 mm s-1, over a track length of 0.8 mm, was performed at 18 °C and 40%-50% relative humidity. Hair fibres retaining their natural sebum were studied, as well as those stripped of their sebum via hexane cleaning, and hair fibres conditioned using a commercially available product. Surface topography modifications resulting from wear were imaged using scanning electron microscopy and quantified using white light interferometry. Hair fibres that presented sebum or conditioned product at the fibre/fibre junction exhibited initial coefficients of friction at least 25% lower than those that were cleaned with hexane. Coefficients of friction were observed to depend on the directionality of sliding for hexane cleaned hair fibres after sufficient wear cycles that cuticle lifting was present, typically on the order 1000 cycles. Cuticle flattening was observed for fibre/fibre junctions exposed to 10 mN compressive normal loads, whereas loads of 100 mN introduced substantial cuticle wear and fibre damage.

  14. Tribology: Friction, lubrication, and wear technology

    Science.gov (United States)

    Blau, Peter J.

    1993-01-01

    The topics are presented in viewgraph form and include the following: introduction and definitions of terms; friction concepts; lubrication technology concepts; wear technology concepts; and tribological transitions. This document is designed for educators who seek to teach these concepts to their students.

  15. Powdered Hexagonal Boron Nitride Reducing Nanoscale Wear

    Science.gov (United States)

    Chkhartishvili, L.; Matcharashvili, T.; Esiava, R.; Tsagareishvili, O.; Gabunia, D.; Margiev, B.; Gachechiladze, A.

    2013-05-01

    A morphology model is suggested for nano-powdered hexagonal boron nitride that can serve as an effective solid additive to liquid lubricants. It allows to estimate the specific surface, that is a hard-to-measure parameter, based on average size of powder particles. The model can be used also to control nanoscale wear processes.

  16. Parameter Estimation of a Delay Time Model of Wearing Parts Based on Objective Data

    Directory of Open Access Journals (Sweden)

    Y. Tang

    2015-01-01

    Full Text Available The wearing parts of a system have a very high failure frequency, making it necessary to carry out continual functional inspections and maintenance to protect the system from unscheduled downtime. This allows for the collection of a large amount of maintenance data. Taking the unique characteristics of the wearing parts into consideration, we establish their respective delay time models in ideal inspection cases and nonideal inspection cases. The model parameters are estimated entirely using the collected maintenance data. Then, a likelihood function of all renewal events is derived based on their occurring probability functions, and the model parameters are calculated with the maximum likelihood function method, which is solved by the CRM. Finally, using two wearing parts from the oil and gas drilling industry as examples—the filter element and the blowout preventer rubber core—the parameters of the distribution function of the initial failure time and the delay time for each example are estimated, and their distribution functions are obtained. Such parameter estimation based on objective data will contribute to the optimization of the reasonable function inspection interval and will also provide some theoretical models to support the integrity management of equipment or systems.

  17. Corrosive wear. Evaluation of wear and corrosive resistant materials; Noetningskorrosion. Utvaerdering av noetnings- och korrosionsbestaendiga material

    Energy Technology Data Exchange (ETDEWEB)

    Persson, H.; Hjertsen, D.; Waara, P.; Prakash, B.; Hardell, J.

    2007-12-15

    With a new purchase of a waste conveyer screw at hand, for the 'A-warehouse' at the combined power and heating plant at E.ON Norrkoeping, the request for improved construction materials was raised. The previous screw required maintenance with very short intervals due to the difficult operation conditions. With the new screw the expectation is to manage 6 months of operation without interruption. The environment for the screw has two main components that sets the demand on the materials, on one hand the corrosive products that comes along and which forms at digestion of the waste and on the other hand the abrasive content in the waste. The term of the mechanism is wear-corrosion and can give considerably higher material loss than the two mechanisms wear and corrosion separately. Combination of a strong corrosive environment together with extensive wear is something that we today have limited knowledge about. The overall objective of the project has been to establish better wear and corrosive resistant construction materials for a waste conveyer screw that will lead to reduced operational disturbance costs. The evaluation has been performed in both controlled laboratory environments and in field tests, which has given us a better understanding of what materials are more suitable in this tough environment and has given us a tool for future predictions of the wear rate of the different material. The new conveyer screw, installed in February 2007 and with which the field test have been performed, has considerably reduced the wear of the construction and the target of 6 month maintenance-free operation is met with this screw for all the evaluated materials. The wear along the screw varies very much and with a clear trend for all the materials to increase towards the feeding direction of the screw. As an example, the wear plate SS2377 (stainless duplex steel) has a useful life at the most affected areas that is calculated to be 1077 days of operation with the

  18. Structurally Integrated Coatings for Wear and Corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Beardsley, M. Brad; Sebright, Jason L.

    2008-11-18

    Wear and corrosion of structures cuts across industries and continues to challenge materials scientists and engineers to develop cost effective solutions. Industries typically seek mature technologies that can be implemented for production with rapid or minimal development and have little appetite for the longer-term materials research and development required to solve complex problems. The collaborative work performed in this project addressed the complexity of this problem in a multi-year program that industries would be reluctant to undertake without government partnership. This effort built upon the prior development of Advanced Abrasion Resistant Materials conduct by Caterpillar Inc. under DOE Cooperative Agreement No. DE-FC26-01NT41054. In this referenced work, coatings were developed that exhibited significant wear life improvements over standard carburized heat treated steel in abrasive wear applications. The technology used in this referenced work, arc lamp fusing of thermal spray coatings, was one of the primary technical paths in this work effort. In addition to extending the capability of the coating technology to address corrosion issues, additional competitive coating technologies were evaluated to insure that the best technology was developed to meet the goals of the program. From this, plasma transferred arc (PTA) welding was selected as the second primary technology that was investigated. Specifically, this project developed improved, cost effective surfacing materials and processes for wear and corrosion resistance in both sliding and abrasive wear applications. Materials with wear and corrosion performance improvements that are 4 to 5 times greater than heat treated steels were developed. The materials developed were based on low cost material systems utilizing ferrous substrates and stainless steel type matrix with hard particulates formed from borides and carbides. Affordability was assessed against other competing hard surfacing or coating

  19. STUDY ON WEAR AND DESTRUCTION OF HOB IN GEAR HOBBING

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The wear and destruction appearances of hobs are researched. The reasons of the wear and destruction of hobare analyzed. And the influence of the change of the hobbing force and the hobbing temperature on the wear and destruc-tion of hob in gear hobbing is also analyzed. In gear hobbing, the main wear mechanisms are adhesion and ploughingwhen cutting the 20CrMnTi gear using W 18Cr4V high-speed steel hob.

  20. New synthesizing feature parameter of wear particles image

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    This paper outlines the application of wavelet analysis method to computering wear par-ticles image processing and introduces the concept of grain parameter for wear particle imagebased on statistical feature parameters. The feature of wear particles image can be obtained fromthe wavelet decomposition and the statistics analysis. Test results showed that grain parametercan be used as a synthesizing feature parameter for wear particle image.

  1. A panorama of tooth wear during the medieval period.

    Science.gov (United States)

    Esclassan, Rémi; Hadjouis, Djillali; Donat, Richard; Passarrius, Olivier; Maret, Delphine; Vaysse, Frédéric; Crubézy, Eric

    2015-01-01

    Tooth wear is a natural phenomenon and a universal occurrence that has existed from the origin of humankind and depends on the way of life, especially diet. Tooth wear was very serious in ancient populations up to the medieval period. The aim of this paper is to present a global view of tooth wear in medieval times in Europe through different parameters: scoring systems, quantity and direction of wear, gender, differences between maxilla and mandible, relations with diet, caries, tooth malpositions and age.

  2. An On-line Ferrograph for Monitoring Machine Wear

    Institute of Scientific and Technical Information of China (English)

    L(U) Xiao-jun; JING Min-qing; XIE You-bai

    2005-01-01

    In order to improve an on-line ferrograph, this paper simulates a three dimensional magnetic field distribution of an electromagnet, builds a sinking motion model of a wear particle, and investigates the motion law of wear particles under two different conditions. Both numeric results and experimental results show that the on-line ferrograph is capable of monitoring machine wear conditions by measuring the concentration and size distribution of wear particles in lubricating oil.

  3. Wear numbers for ball cup and journal bearings

    OpenAIRE

    Ligterink, D.J.; Moes, H.

    1980-01-01

    A wear number is defined for ball cup bearings and for journal bearings where the cup and the cylindrical bearing are made of soft material. This dimensionless wear number provides a relation between the following five quantities: the radius of the ball or the length of the journal bearing in millimetres, the wear modulus in newtons per square millimetre, the maximum wear depth rate of the cup or the cylindrical bearing in millimetres per second, the force between the mating surfaces in newto...

  4. Failure of total hip implants: metals and metal release in 52 cases

    DEFF Research Database (Denmark)

    Jakobsen, Stig Storgaard; Lidén, Carola; Søballe, Kjeld;

    2014-01-01

    Background . The pathogenesis of total joint replacement failure is multifactorial. One hypothesis suggests that corrosion and wear of alloys result in metal ion release, which may then cause sensitization and even implant failure, owing to the acquired immune reactivity. Objectives . To assess c...

  5. Assessment of Corrosion, Fretting, and Material Loss of Retrieved Modular Total Knee Arthroplasties.

    Science.gov (United States)

    Martin, Audrey J; Seagers, Kirsten A; Van Citters, Douglas W

    2017-07-01

    Modular junctions in total hip arthroplasties have been associated with fretting, corrosion, and debris release. The purpose of this study is to analyze damage severity in total knee arthroplasties of a single design by qualitative visual assessment and quantitative material loss measurements to evaluate implant performance and patient impact via material loss. Twenty-two modular knee retrievals of the same manufacturer were identified from an institutional review board-approved database. Junction designs included tapers with an axial screw and tapers with a radial screw. Constructs consisted of 2 metal alloys: CoCr and Ti6Al4V. Components were qualitatively scored and quantitatively measured for corrosion and fretting. Negative values represent adhered material. Statistical differences were analyzed using sign tests. Correlations were tested with a Spearman rank order test (P material loss and the maximum linear depth for the total population were -0.23 mm(3) and 5.84 μm, respectively. CoCr components in mixed metal junctions had higher maximum linear depth (P = .007) than corresponding Ti components. Fretting scores of Ti6Al4V alloy components in mixed metal junctions were statistically higher than the remaining groups. Taper angle did not correlate with material loss. Results suggest that CoCr components in mixed metal junctions are more vulnerable to corrosion than other components, suggesting preferential corrosion when interfacing with Ti6Al4V. Overall, although corrosion was noted in this series, material loss was low, and none were revised for clinical metal-related reaction. This suggests the clinical impact from corrosion in total knee arthroplasty is low. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. The spatiotemporal pattern of Src activation at lipid rafts revealed by diffusion-corrected FRET imaging.

    Directory of Open Access Journals (Sweden)

    Shaoying Lu

    Full Text Available Genetically encoded biosensors based on fluorescence resonance energy transfer (FRET have been widely applied to visualize the molecular activity in live cells with high spatiotemporal resolution. However, the rapid diffusion of biosensor proteins hinders a precise reconstruction of the actual molecular activation map. Based on fluorescence recovery after photobleaching (FRAP experiments, we have developed a finite element (FE method to analyze, simulate, and subtract the diffusion effect of mobile biosensors. This method has been applied to analyze the mobility of Src FRET biosensors engineered to reside at different subcompartments in live cells. The results indicate that the Src biosensor located in the cytoplasm moves 4-8 folds faster (0.93+/-0.06 microm(2/sec than those anchored on different compartments in plasma membrane (at lipid raft: 0.11+/-0.01 microm(2/sec and outside: 0.18+/-0.02 microm(2/sec. The mobility of biosensor at lipid rafts is slower than that outside of lipid rafts and is dominated by two-dimensional diffusion. When this diffusion effect was subtracted from the FRET ratio images, high Src activity at lipid rafts was observed at clustered regions proximal to the cell periphery, which remained relatively stationary upon epidermal growth factor (EGF stimulation. This result suggests that EGF induced a Src activation at lipid rafts with well-coordinated spatiotemporal patterns. Our FE-based method also provides an integrated platform of image analysis for studying molecular mobility and reconstructing the spatiotemporal activation maps of signaling molecules in live cells.

  7. PEG-Phospholipids Coated Quantum Rods as Amplifiers of the Photosensitization Process by FRET.

    Science.gov (United States)

    Timor, Reut; Weitman, Hana; Waiskopf, Nir; Banin, Uri; Ehrenberg, Benjamin

    2015-09-30

    Singlet oxygen ((1)O2) generated upon photostimulation of photosensitizer molecules is a highly reactive specie which is utilized in photodynamic therapy. Recent studies have shown that semiconductor nanoparticles can be used as donors in fluorescence resonance energy transfer (FRET) process to excite attached photosensitizer molecules. In these studies, their unique properties, such as low nanoscale size, long-term photostability, wide broad absorbance band, large absorption cross section, and narrow and tunable emission bands were used to provide advantages over the traditional methods to produce singlet oxygen. Previous studies that achieved this goal, however, showed some limitations, such as low FRET efficiency, poor colloidal stability, nonspecific interactions, and/or complex preparation procedure. In this work, we developed and characterized a novel system of semiconductor quantum rods (QRs) and the photosensitizer meso-tetra(hydroxyphenyl) chlorin (mTHPC), as a model system that produces singlet oxygen without these limitations. A simple two-step preparation method is shown; Hydrophobic CdSe/CdS QRs are solubilized in aqueous solutions by encapsulation with lecithin and PEGylated phospholipid (PEG-PL) of two lipid lengths: PEG350 or PEG2000. Then, the hydrophobic photosensitizer mTHPC, was intercalated into the new amphiphilic PEG-PL coating of the QR, providing a strong attachment to the nanoparticle without covalent linkage. These PEGylated QR (eQR)-mTHPC nanocomposites show efficient FRET processes upon light stimulation of the QR component which results in efficient production of singlet oxygen. The results demonstrate the potential for future use of this concept in photodynamic therapy schemes.

  8. FRET-based localization of fluorescent protein insertions within the ryanodine receptor type 1.

    Directory of Open Access Journals (Sweden)

    Shweta A Raina

    Full Text Available Fluorescent protein (FP insertions have often been used to localize primary structure elements in mid-resolution 3D cryo electron microscopic (EM maps of large protein complexes. However, little is known as to the precise spatial relationship between the location of the fused FP and its insertion site within a larger protein. To gain insights into these structural considerations, Förster resonance energy transfer (FRET measurements were used to localize green fluorescent protein (GFP insertions within the ryanodine receptor type 1 (RyR1, a large intracellular Ca(2+ release channel that plays a key role in skeletal muscle excitation contraction coupling. A series of full-length His-tagged GFP-RyR1 fusion constructs were created, expressed in human embryonic kidney (HEK-293T cells and then complexed with Cy3NTA, a His-tag specific FRET acceptor. FRET efficiency values measured from each GFP donor to Cy3NTA bound to each His tag acceptor site were converted into intermolecular distances and the positions of each inserted GFP were then triangulated relative to a previously published X-ray crystal structure of a 559 amino acid RyR1 fragment. We observed that the chromophoric centers of fluorescent proteins inserted into RyR1 can be located as far as 45 Å from their insertion sites and that the fused proteins can also be located in internal cavities within RyR1. These findings should prove useful in interpreting structural results obtained in cryo EM maps using fusions of small fluorescent proteins. More accurate point-to-point distance information may be obtained using complementary orthogonal labeling systems that rely on fluorescent probes that bind directly to amino acid side chains.

  9. FRET-based localization of fluorescent protein insertions within the ryanodine receptor type 1.

    Science.gov (United States)

    Raina, Shweta A; Tsai, Jeffrey; Samsó, Montserrat; Fessenden, James D

    2012-01-01

    Fluorescent protein (FP) insertions have often been used to localize primary structure elements in mid-resolution 3D cryo electron microscopic (EM) maps of large protein complexes. However, little is known as to the precise spatial relationship between the location of the fused FP and its insertion site within a larger protein. To gain insights into these structural considerations, Förster resonance energy transfer (FRET) measurements were used to localize green fluorescent protein (GFP) insertions within the ryanodine receptor type 1 (RyR1), a large intracellular Ca(2+) release channel that plays a key role in skeletal muscle excitation contraction coupling. A series of full-length His-tagged GFP-RyR1 fusion constructs were created, expressed in human embryonic kidney (HEK)-293T cells and then complexed with Cy3NTA, a His-tag specific FRET acceptor. FRET efficiency values measured from each GFP donor to Cy3NTA bound to each His tag acceptor site were converted into intermolecular distances and the positions of each inserted GFP were then triangulated relative to a previously published X-ray crystal structure of a 559 amino acid RyR1 fragment. We observed that the chromophoric centers of fluorescent proteins inserted into RyR1 can be located as far as 45 Å from their insertion sites and that the fused proteins can also be located in internal cavities within RyR1. These findings should prove useful in interpreting structural results obtained in cryo EM maps using fusions of small fluorescent proteins. More accurate point-to-point distance information may be obtained using complementary orthogonal labeling systems that rely on fluorescent probes that bind directly to amino acid side chains.

  10. Steady-state acceptor fluorescence anisotropy imaging under evanescent excitation for visualisation of FRET at the plasma membrane.

    Directory of Open Access Journals (Sweden)

    Viviane Devauges

    Full Text Available We present a novel imaging system combining total internal reflection fluorescence (TIRF microscopy with measurement of steady-state acceptor fluorescence anisotropy in order to perform live cell Förster Resonance Energy Transfer (FRET imaging at the plasma membrane. We compare directly the imaging performance of fluorescence anisotropy resolved TIRF with epifluorescence illumination. The use of high numerical aperture objective for TIRF required correction for induced depolarization factors. This arrangement enabled visualisation of conformational changes of a Raichu-Cdc42 FRET biosensor by measurement of intramolecular FRET between eGFP and mRFP1. Higher activity of the probe was found at the cell plasma membrane compared to intracellularly. Imaging fluorescence anisotropy in TIRF allowed clear differentiation of the Raichu-Cdc42 biosensor from negative control mutants. Finally, inhibition of Cdc42 was imaged dynamically in live cells, where we show temporal changes of the activity of the Raichu-Cdc42 biosensor.

  11. Transition metal ion FRET to measure short-range distances at the intracellular surface of the plasma membrane.

    Science.gov (United States)

    Gordon, Sharona E; Senning, Eric N; Aman, Teresa K; Zagotta, William N

    2016-02-01

    Biological membranes are complex assemblies of lipids and proteins that serve as platforms for cell signaling. We have developed a novel method for measuring the structure and dynamics of the membrane based on fluorescence resonance energy transfer (FRET). The method marries four technologies: (1) unroofing cells to isolate and access the cytoplasmic leaflet of the plasma membrane; (2) patch-clamp fluorometry (PCF) to measure currents and fluorescence simultaneously from a membrane patch; (3) a synthetic lipid with a metal-chelating head group to decorate the membrane with metal-binding sites; and (4) transition metal ion FRET (tmFRET) to measure short distances between a fluorescent probe and a transition metal ion on the membrane. We applied this method to measure the density and affinity of native and introduced metal-binding sites in the membrane. These experiments pave the way for measuring structural rearrangements of membrane proteins relative to the membrane.

  12. Severe tooth wear: European consensus statement on management guidelines

    DEFF Research Database (Denmark)

    Loomans, Bas AC; Opdam, Niek JM; Attin, Thomas

    2017-01-01

    This paper reports a European expert consensus statement on guidelines for the management of severe tooth wear. It focuses on the definition of physiological versus pathological tooth wear and recommends diagnosis, monitoring and counseling to define the activity of the wear. Restorative...

  13. 16 CFR 423.6 - Textile wearing apparel.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Textile wearing apparel. 423.6 Section 423.6 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES CARE LABELING OF TEXTILE WEARING APPAREL AND CERTAIN PIECE GOODS AS AMENDED § 423.6 Textile wearing apparel. This section applies to...

  14. TECHNIQUE OF TESTING ON FRETTING AT THE SPHERE-TO-PLANE CONTACT

    Directory of Open Access Journals (Sweden)

    А. Khimko

    2012-12-01

    Full Text Available  The methodology of conducting tests on fretting at the sphere-to-plane contact was developed for the wing mechanization unit, namely for screw-nut pair with intermediate balls. Wearability tests were conducted on a modified installation МФК-1, the feature of which is the designed holder that allows testing with real balls. It was found that at the dry contact of ШХ-15 and 30Х2НВФA materials, surface microcracks are formed due to welding of microasperities areas and their rupture under the influence of vibration.

  15. Protein-protein interactions in the plant Golgi apparatus, studied with FRET acceptor photobleaching technique

    DEFF Research Database (Denmark)

    Poulsen, Christian Peter

    to the plant Golgi apparatus and involved mainly in arabinogalactan protein (AGP) biosynthesis. Co-expression analysis identified 4 GTs and 4 NSTs possibly involved in AGP biosynthesis. As part of the method development, the cytoskeleton-acting agent Cytochalasin D was tested as an inhibitor...... of the actinomyosin based movement of Golgi vesicles, and was proved to be superior to commonly used fixatives such as the cross-linking agent paraformaldehyde which causes quenching of the fluorophores. According to FRET analysis, the results showed association between two galactosyltransferases, AtGALT29A and At...

  16. Multiphoton STED and FRET in human skin: Resolving the skin barrier

    DEFF Research Database (Denmark)

    Antonescu, Irina; Dreier, Jes; Brewer, Jonathan R.

    Understanding the penetration properties of substances across biological bar- riers and membranes is vital for many areas of research. In the case of human skin, the barrier is primarily found in the stratum corneum and consists of protein-enriched cells surrounded by a lipid membrane -enriched...... excited STED and Forster Resonance Energy Transfer (FRET) microscopy to probe the structure of human skin. Super resolution optical microscopy enables resolving structures in the skin below to 60 nm allowing visualization of the stratum corneum intercellular lipid matrix and individual proteins...

  17. Experimental evaluation of the fretting fatigue behavior of high-strength steel monostrands

    DEFF Research Database (Denmark)

    Winkler, Jan; Fischer, Gregor; Georgakis, Christos T.

    2013-01-01

    . Moreover, the paper provides relevant information about the monostrand bending stiffness and the extent of relative displacement between core and outer wires of the monostrand undergoing flexural deformations. The results presented herein are of special interest for the fatigue analysis of modern stay......In this paper, the fretting fatigue behavior of pretensioned high-strength steel monostrands is investigated. A method based on the digital image correlation (DIC) technique was used to quantify the relative movement between individual wires along the length of the monostrand. The experimental data...

  18. Compound parabolic concentrator optical fiber tip for FRET-based fluorescent sensors

    DEFF Research Database (Denmark)

    Hassan, Hafeez Ul; Nielsen, Kristian; Aasmul, Soren;

    2015-01-01

    polymer optical fiber for an excitation and emission wavelength of 550 nm and 650nm, respectively. The model suggests an increase of a factor of 1.6 to 4 in the collected fluorescent power for an ideal CPC tip, as compared to the plane-cut fiber tip for fiber lengths between 5 and 45mm......The Compound Parabolic Concentrator (CPC) optical fiber tip shape has been proposed for intensity based fluorescent sensors working on the principle of FRET (Förster Resonance Energy Transfer). A simple numerical Zemax model has been used to optimize the CPC tip geometry for a step-index multimode...

  19. Analysis of temporal and spatial contact voltage fluctuation during fretting in automotive connectors

    OpenAIRE

    El Mossouess, Sofiane; Benjemâa, N; Carvou, E; El Abdi, R; Obame, H; Doublet, L; Rodari, T

    2014-01-01

    International audience; Our study is focused on contact voltage fluctuations during fretting with small amplitudes of a few tens microns which generate damage of the contact of connectors. A contact composed by a pin and a curve female part are submitted to vibration cyclic of 25µm at 100Hz and supplied with current ramp from 0.1mA to 3A in two directions. With the help of fast devices, the voltage and position data acquisition are conjointly made with the common DC contact voltage dur-ing fr...

  20. Respiratory failure

    Institute of Scientific and Technical Information of China (English)

    1997-01-01

    970318 A study on evoked potentials in cor pul-monale patients with chronic respiratory failure.QIAO Hui(乔慧), et al. Beijing Neurosurg Instit,Beijing, 100050. Chin J Geriatr 1997; 16(1): 43-45. Objective: Evoked protential was used to detect thechange of brain function in cor pulmonale patients with