WorldWideScience

Sample records for fresh blood imaging

  1. Capabilities of diffusion-weighted and fresh blood imaging in depicting fresh thrombus. Presidential award proceedings

    International Nuclear Information System (INIS)

    Ando, Ritsuko; Manabe, Tsutomu; Tazawa, Satoru

    2007-01-01

    We examined the capabilities of diffusion-weighted (DWI) and fresh-blood imaging (FBI) in depicting thrombus. A paper-clay phantom holding test syringes of various sizes filled with either contrast medium or fresh human blood were scanned using a 1.5T magnetic resonance (MR) imaging unit, and apparent diffusion coefficient (ADC) values and signal intensities on DWI and FBI of the specimens were obtained. FBI depicted all the specimens regardless of syringe diameter, but DWI failed to image the syringe measuring 0.5 cm in diameter. B-factors and/or number of acquisitions (NAQ) seemed responsible for DWI's depiction capability. ADC values and signal intensities on DWI and FBI correlated with the viscosity of the contrast medium samples. Clotted blood, the most viscous of the samples, had the smallest ADC value and no relationship with signal intensities on DWI and FBI. Larger b-factors reduced signal intensity in contrast medium on DWI, but signals decreased only minimally in clotted blood. The result suggested that although viscosity was the influential factor for signal intensities on DWI in contrast medium, other factors, such as particle sizes of fibrin and hemoglobin, accounted for the low ADC values in clotting blood. T 2 relaxation time seemed to play a significant role in making signal intensities on DWI irrelevant to b-factors. Despite lapsed time, the clots were persistently hyperintense on FBI with a tendency to decrease only gradually. On DWI, there was a certain period when signal intensities were high and ADC values were low. The signal intensities on DWI and ADC values were considered to be influenced by the process of clot formation, and disappearance of signal seemed likely attributable to degeneration of protein and organization of the clot. (author)

  2. Warm fresh whole blood and thoracic traumain iraq and afghanistan.

    Science.gov (United States)

    Keneally, Ryan J; Parsons, Andrew M; Willett, Peter B

    2015-01-01

    Thoracic trauma occurred in 10% of the patients seen at US military treatment facilities in Iraq and Afghanistan and 52% of those patients were transfused. Among those transfused, 281 patients received warm fresh whole blood. A previous report documented improved survival with warm fresh whole blood in patients injured in combat without stratification by injury pattern. A later report described an increase in acute lung injuries after its administration. Survivorship and warm fresh whole blood have never been analyzed in a subpopulation at highest risk for lung injuries, such as patients with thoracic trauma. There may be a heterogeneous relationship between whole blood and survival based on likelihood of a concomitant pulmonary injury. In this report, the relationship between warm fresh whole blood and survivorship was analyzed among patients at highest risk for concomitant pulmonary injuries. Patients with thoracic trauma who received a transfusion were identified in the Joint Theater Trauma Registry. Gross mortality rates were compared between whole blood recipients and patients transfused with component therapy only. The association between each blood component and mortality was determined in a regression model. The overall mortality risk was compared between warm fresh whole blood recipients and non-recipients. Patients transfused with warm fresh whole blood in addition to component therapy had a higher mortality rate than patients transfused only separated blood components (21.3% vs. 12.8%, P warm fresh whole blood in addition to component therapy was not associated with increased mortality risk compared with the transfusion of component therapy only (OR 1.247 [95% CI 0.760-2.048], P = 0.382). Patients with combat related thoracic trauma transfused with warm fresh whole blood were not at increased risk for mortality compared to those who received component therapy alone when controlling for covariates.

  3. Efficacy of fresh packed red blood transfusion in organophosphate poisoning.

    Science.gov (United States)

    Bao, Hang-Xing; Tong, Pei-Jian; Li, Cai-Xia; Du, Jing; Chen, Bing-Yu; Huang, Zhi-Hui; Wang, Ying

    2017-03-01

    The mortality rate caused by organophosphate (OP) poisoning is still high, even the standard treatment such as atropine and oxime improves a lot. To search for alternative therapies, this study was aimed to investigate the effects of packed red blood cell (RBC) transfusion in acute OP poisoning, and compare the therapeutic effects of RBCs at different storage times.Patients diagnosed with OP poisoning were included in this prospective study. Fresh RBCs (packed RBCs stored less than 10 days) and longer-storage RBCs (stored more than 10 days but less than 35 days) were randomly transfused or not into OP poisoning patients. Cholinesterase (ChE) levels in blood, atropine usage and durations, pralidoxime durations were measured.We found that both fresh and longer-storage RBCs (200-400 mL) significantly increased blood ChE levels 6 hours after transfusion, shortened the duration for ChE recovery and length of hospital stay, and reduced the usage of atropine and pralidoxime. In addition, fresh RBCs demonstrated stronger therapeutic effects than longer-storage RBCs.Packed RBCs might be an alternative approach in patients with OP poisoning, especially during early stages.

  4. Diet enriched with fresh coconut decreases blood glucose levels and body weight in normal adults.

    Science.gov (United States)

    Vijayakumar, Venugopal; Shankar, Nagashree R; Mavathur, Ramesh; Mooventhan, A; Anju, Sood; Manjunath, N K

    2018-02-20

    Background There exist controversies about the health effects of coconut. Fresh coconut consumption on human health has not been studied substantially. Fresh coconut consumption is a regular part of the diet for many people in tropical countries like India, and thus there is an increasing need to understand the effects of fresh coconut on various aspects of health. Aim To compare the effects of increased saturated fatty acid (SFA) and fiber intake, provided by fresh coconut, versus monounsaturated fatty acid (MUFA) and fiber intake, provided by a combination of groundnut oil and groundnuts, on anthropometry, serum insulin, glucose levels and blood pressure in healthy adults. Materials Eighty healthy volunteers, randomized into two groups, were provided with a standardized diet along with either 100 g fresh coconut or an equivalent amount of groundnuts and groundnut oil for a period of 90 days. Assessments such as anthropometric measurements, blood pressure, blood sugar and insulin levels were performed before and after the supplementation period. Results Results of this study showed a significant reduction in fasting blood sugar (FBS) in both the groups. However, a significant reduction in body weight was observed in the coconut group, while a significant increase in diastolic pressure was observed in the groundnut group. Conclusions Results of this study suggest that fresh coconut-added diet helps reduce blood glucose levels and body weight in normal healthy individuals.

  5. On-line fresh-cut lettuce quality measurement system using hyperspectral imaging

    Science.gov (United States)

    Lettuce, which is a main type of fresh-cut vegetable, has been used in various fresh-cut products. In this study, an online quality measurement system for detecting foreign substances on the fresh-cut lettuce was developed using hyperspectral reflectance imaging. The online detection system with a s...

  6. Fluorescence hyper-spectral imaging to detecting faecal contamination on fresh tomatoes

    Directory of Open Access Journals (Sweden)

    Roberto Romaniello

    2016-03-01

    Full Text Available Faecal contamination of fresh fruits represents a severe danger for human health. Thus some techniques based on microbiological testing were developed to individuate faecal contaminants but those tests do not results efficient because their non-applicability on overall vegetable unity. In this work a methodology based on hyper-spectral fluorescence imaging was developed and tested to detecting faecal contamination on fresh tomatoes. Two image-processing methods were performed to maximise the contrast between the faecal contaminant and tomatoes skin: principal component analysis and band image ratio (BRI. The BRI method allows classifying correctly 70% of contaminated area, with no false-positives in all examined cases. Thus, the developed methodology can be employed for a fast and effective detection of faecal contamination on fresh tomatoes.

  7. Quantify Glucose Level in Freshly Diabetic's Blood by Terahertz Time-Domain Spectroscopy

    Science.gov (United States)

    Chen, Hua; Chen, Xiaofeng; Ma, Shihua; Wu, Xiumei; Yang, Wenxing; Zhang, Weifeng; Li, Xiao

    2018-04-01

    We demonstrate the capability of terahertz (THz) time-domain spectroscopy (TDS) to quantify glucose level in ex vivo freshly diabetic's blood. By investigating the THz spectra of different human blood, we find out THz absorption coefficients reflect a high sensitivity to the glucose level in blood. With a quantitative analysis of 70 patients, we demonstrate that the THz absorption coefficients and the blood glucose levels perform a linear relationship. A comparative experiment between THz measurement and glucometers is also conducted with another 20 blood samples, and the results confirm that the relative error is as less as 15%. Our ex vivo human blood study indicates that THz technique has great potential application to diagnose blood glucose level in clinical practice.

  8. Fluorescence hyperspectral imaging technique for foreign substance detection on fresh-cut lettuce.

    Science.gov (United States)

    Mo, Changyeun; Kim, Giyoung; Kim, Moon S; Lim, Jongguk; Cho, Hyunjeong; Barnaby, Jinyoung Yang; Cho, Byoung-Kwan

    2017-09-01

    Non-destructive methods based on fluorescence hyperspectral imaging (HSI) techniques were developed to detect worms on fresh-cut lettuce. The optimal wavebands for detecting the worms were investigated using the one-way ANOVA and correlation analyses. The worm detection imaging algorithms, RSI-I (492-626)/492 , provided a prediction accuracy of 99.0%. The fluorescence HSI techniques indicated that the spectral images with a pixel size of 1 × 1 mm had the best classification accuracy for worms. The overall results demonstrate that fluorescence HSI techniques have the potential to detect worms on fresh-cut lettuce. In the future, we will focus on developing a multi-spectral imaging system to detect foreign substances such as worms, slugs and earthworms on fresh-cut lettuce. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  9. Elimination of heparin interference during microarray processing of fresh and biobank-archived blood samples.

    Science.gov (United States)

    Hebels, Dennie G A J; van Herwijnen, Marcel H M; Brauers, Karen J J; de Kok, Theo M C M; Chalkiadaki, Georgia; Kyrtopoulos, Soterios A; Kleinjans, Jos C S

    2014-07-01

    In the context of environmental health research, biobank blood samples have recently been identified as suitable for high-throughput omics analyses enabling the identification of new biomarkers of exposure and disease. However, blood samples containing the anti-coagulant heparin could complicate transcriptomic analysis because heparin may inhibit RNA polymerase causing inefficient cRNA synthesis and fluorophore labelling. We investigated the inhibitory effect of heparin and the influence of storage conditions (0 or 3 hr bench times, storage at room temperature or -80°C) on fluorophore labelling in heparinized fresh human buffy coat and whole blood biobank samples during the mRNA work-up protocol for microarray analysis. Subsequently, we removed heparin by lithium chloride (LiCl) treatment and performed a quality control analysis of LiCl-treated biobank sample microarrays to prove their suitability for downstream data analysis. Both fresh and biobank samples experienced varying degrees of heparin-induced inhibition of fluorophore labelling, making most samples unusable for microarray analysis. RNA derived from EDTA and citrate blood was not inhibited. No effect of bench time was observed but room temperature storage gave slightly better results. Strong correlations were observed between original blood sample RNA yield and the amount of synthesized cRNA. LiCl treatment restored sample quality to normal standards in both fresh and biobank samples and the previously identified correlations disappeared. Microarrays hybridized with LiCl-treated biobank samples were of excellent quality with no identifiable influence of heparin. We conclude that, to obtain high quality results, in most cases heparin removal is essential in blood-derived RNA samples intended for microarray analysis. Copyright © 2014 Wiley Periodicals, Inc.

  10. Near-Infrared Confocal Laser Reflectance Cytoarchitectural Imaging of the Substantia Nigra and Cerebellum in the Fresh Human Cadaver.

    Science.gov (United States)

    Cheyuo, Cletus; Grand, Walter; Balos, Lucia L

    2017-01-01

    Cytoarchitectural neuroimaging remains critical for diagnosis of many brain diseases. Fluorescent dye-enhanced, near-infrared confocal in situ cellular imaging of the brain has been reported. However, impermeability of the blood-brain barrier to most fluorescent dyes limits clinical utility of this modality. The differential degree of reflectance from brain tissue with unenhanced near-infrared imaging may represent an alternative technique for in situ cytoarchitectural neuroimaging. We assessed the utility of unenhanced near-infrared confocal laser reflectance imaging of the cytoarchitecture of the cerebellum and substantia nigra in 2 fresh human cadaver brains using a confocal near-infrared laser probe. Cellular images based on near-infrared differential reflectance were captured at depths of 20-180 μm from the brain surface. Parts of the cerebellum and substantia nigra imaged using the probe were subsequently excised and stained with hematoxylin and eosin for histologic correlation. Near-infrared reflectance imaging revealed the 3-layered cytoarchitecture of the cerebellum, with Purkinje cells appearing hyperreflectant. In the substantia nigra, neurons appeared hyporeflectant with hyperreflectant neuromelanin cytoplasmic inclusions. Cytoarchitecture of the cerebellum and substantia nigra revealed on near-infrared imaging closely correlated with the histology on hematoxylin-eosin staining. We showed that unenhanced near-infrared reflectance imaging of fresh human cadaver brain can reliably identify and distinguish neurons and detailed cytoarchitecture of the cerebellum and substantia nigra. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. A rapid and efficient DNA extraction protocol from fresh and frozen human blood samples.

    Science.gov (United States)

    Guha, Pokhraj; Das, Avishek; Dutta, Somit; Chaudhuri, Tapas Kumar

    2018-01-01

    Different methods available for extraction of human genomic DNA suffer from one or more drawbacks including low yield, compromised quality, cost, time consumption, use of toxic organic solvents, and many more. Herein, we aimed to develop a method to extract DNA from 500 μL of fresh or frozen human blood. Five hundred microliters of fresh and frozen human blood samples were used for standardization of the extraction procedure. Absorbance at 260 and 280 nm, respectively, (A 260 /A 280 ) were estimated to check the quality and quantity of the extracted DNA sample. Qualitative assessment of the extracted DNA was checked by Polymerase Chain reaction and double digestion of the DNA sample. Our protocol resulted in average yield of 22±2.97 μg and 20.5±3.97 μg from 500 μL of fresh and frozen blood, respectively, which were comparable to many reference protocols and kits. Besides yielding bulk amount of DNA, our protocol is rapid, economical, and avoids toxic organic solvents such as Phenol. Due to unaffected quality, the DNA is suitable for downstream applications. The protocol may also be useful for pursuing basic molecular researches in laboratories having limited funds. © 2017 Wiley Periodicals, Inc.

  12. SMA Diagnosis: Detection of SMN1 Deletion with Real-Time mCOP-PCR System Using Fresh Blood DNA.

    Science.gov (United States)

    Niba, Emma Tabe Eko; Ar Rochmah, Mawaddah; Harahap, Nur Imma Fatimah; Awano, Hiroyuki; Morioka, Ichiro; Iijima, Kazumoto; Saito, Toshio; Saito, Kayoko; Takeuchi, Atsuko; Lai, Poh San; Bouike, Yoshihiro; Nishio, Hisahide; Shinohara, Masakazu

    2017-12-18

    Spinal muscular atrophy (SMA) is one of the most common autosomal recessive disorders. The symptoms are caused by defects of lower motor neurons in the spinal cord. More than 95% of SMA patients are homozygous for survival motor neuron 1 (SMN1) deletion. We previously developed a screening system for SMN1 deletion based on a modified competitive oligonucleotide priming-PCR (mCOP-PCR) technique using dried blood spot (DBS) on filter paper. This system is convenient for mass screening in the large population and/or first-tier diagnostic method of the patients in the remote areas. However, this system was still time-consuming and effort-taking, because it required pre-amplification procedure to avoid non-specific amplification and gel-electrophoresis to detect the presence or absence of SMN1 deletion. When the fresh blood samples are used instead of DBS, or when the gel-electrophoresis is replaced by real-time PCR, we may have a simpler and more rapid diagnostic method for SMA. To establish a simpler and more rapid diagnostic method of SMN1 deletion using fresh blood DNA. DNA samples extracted from fresh blood and stored at 4 ℃ for 1 month. The samples were assayed using a real-time mCOP-PCR system without pre-amplification procedures. DNA samples had already been genotyped by PCR-restriction fragment length polymorphism (PCR-RFLP), showing the presence or absence of SMN1 exon 7. The DNA samples were directly subjected to the mCOP-PCR step. The amplification of mCOP-PCR was monitored in a real-time PCR apparatus. The genotyping results of the real-time mCOP-PCR system using fresh blood DNA were completely matched with those of PCR-RFLP. In this real-time mCOP-PCR system using fresh blood-DNA, it took only four hours from extraction of DNA to detection of the presence or absence of SMN1 deletion, while it took more than 12 hours in PCR-RFLP. Our real-time mCOP-PCR system using fresh blood DNA was rapid and accurate, suggesting it may be useful for the first

  13. Investigation of alpha emitters in fresh and powdered blood of fertile women: an in vitro application of CR-39 NTDs

    International Nuclear Information System (INIS)

    Salih, N.F.; University of Koya, Kurdistan; Jaafar, M.S.

    2014-01-01

    Blood samples were acquired from 60 women aged 20-44 years having decreased fertility, infertile or with uterine tumors in the Iraqi Kurdistan region. The concentrations of α emitters in fresh blood ranged from 0.0029 to 0.0088 ppm, whereas those in powdered blood ranged from 0.0036 ppm in Eiskan to 0.0096 ppm in Halabjay-Kon in Sulaymania. The α emitter concentrations in fresh blood ranged from 0.0029 to 0.0139 ppm, whereas those in powdered blood ranged from 0.0031 ppm in Shorsh to 0.0146 ppm in Sedakan in the Erbil Governorate. However, the concentrations of α emitters in the blood of women with decreased fertility were higher in the North than women from South Iraq. The difference significantly p < 0.001 revealed higher means of track density of fresh and powder blood in Erbil compared to Sulaymania. α are more damaging to the living tissue and exposure of the gonads leads to decreased fertility in women, most of data have been significant therefore, the result shown the radiation effect on women fertility. (author)

  14. Plasma free hemoglobin and microcirculatory response to fresh or old blood transfusions in sepsis.

    Directory of Open Access Journals (Sweden)

    Elisa Damiani

    Full Text Available Free hemoglobin (fHb may induce vasoconstriction by scavenging nitric oxide. It may increase in older blood units due to storage lesions. This study evaluated whether old red blood cell transfusion increases plasma fHb in sepsis and how the microvascular response may be affected.This is a secondary analysis of a randomized study. Twenty adult septic patients received either fresh or old (15 days storage, respectively RBC transfusions. fHb was measured in RBC units and in the plasma before and 1 hour after transfusion. Simultaneously, the sublingual microcirculation was assessed with sidestream-dark field imaging. The perfused boundary region was calculated as an index of glycocalyx damage. Tissue oxygen saturation (StO2 and Hb index (THI were measured with near-infrared spectroscopy and a vascular occlusion test was performed.Similar fHb levels were found in the supernatant of fresh and old RBC units. Despite this, plasma fHb increased in the old RBC group after transfusion (from 0.125 [0.098-0.219] mg/mL to 0.238 [0.163-0.369] mg/mL, p = 0.006. The sublingual microcirculation was unaltered in both groups, while THI increased. The change in plasma fHb was inversely correlated with the changes in total vessel density (r = -0.57 [95% confidence interval -0.82, -0.16], p = 0.008, De Backer score (r = -0.63 [95% confidence interval -0.84, -0.25], p = 0.003 and THI (r = -0.72 [95% confidence interval -0.88, -0.39], p = 0.0003.Old RBC transfusion was associated with an increase in plasma fHb in septic patients. Increasing plasma fHb levels were associated with decreased microvascular density.ClinicalTrials.gov NCT01584999.

  15. Fluorescence hyperspectral imaging technique for the foreign substance detection on fresh-cut lettuce

    Science.gov (United States)

    Nondestructive methods based on fluorescence hyperspectral imaging (HSI) techniques were developed in order to detect worms on fresh-cut lettuce. The optimal wavebands for detecting worms on fresh-cut lettuce were investigated using the one-way ANOVA analysis and correlation analysis. The worm detec...

  16. Discrimination methods of biological contamination on fresh-cut lettuce based on VNIR and NIR hyperspectral imaging

    Science.gov (United States)

    Multispectral imaging algorithms were developed using visible-near-infrared (VNIR) and near-infrared (NIR) hyperspectral imaging (HSI) techniques to detect worms on fresh-cut lettuce. The optimal wavebands that detect worm on fresh-cut lettuce for each type of HSI were investigated using the one-way...

  17. Discrimination methods for biological contaminants in fresh-cut lettuce based on VNIR and NIR hyperspectral imaging

    Science.gov (United States)

    Mo, Changyeun; Kim, Giyoung; Kim, Moon S.; Lim, Jongguk; Lee, Seung Hyun; Lee, Hong-Seok; Cho, Byoung-Kwan

    2017-09-01

    The rapid detection of biological contaminants such as worms in fresh-cut vegetables is necessary to improve the efficiency of visual inspections carried out by workers. Multispectral imaging algorithms were developed using visible-near-infrared (VNIR) and near-infrared (NIR) hyperspectral imaging (HSI) techniques to detect worms in fresh-cut lettuce. The optimal wavebands that can detect worms in fresh-cut lettuce were investigated for each type of HSI using one-way ANOVA. Worm-detection imaging algorithms for VNIR and NIR imaging exhibited prediction accuracies of 97.00% (RI547/945) and 100.0% (RI1064/1176, SI1064-1176, RSI-I(1064-1173)/1064, and RSI-II(1064-1176)/(1064+1176)), respectively. The two HSI techniques revealed that spectral images with a pixel size of 1 × 1 mm or 2 × 2 mm had the best classification accuracy for worms. The results demonstrate that hyperspectral reflectance imaging techniques have the potential to detect worms in fresh-cut lettuce. Future research relating to this work will focus on a real-time sorting system for lettuce that can simultaneously detect various defects such as browning, worms, and slugs.

  18. NMR blood vessel imaging method and apparatus

    International Nuclear Information System (INIS)

    Riederer, S.J.

    1988-01-01

    A high speed method of forming computed images of blood vessels based on measurements of characteristics of a body is described comprising the steps of: subjecting a predetermined body area containing blood vessels of interest to, successively, applications of a short repetition time (TR) NMR pulse sequence during the period of high blood velocity and then to corresponding applications during the period of low blood velocity for successive heart beat cycles; weighting the collected imaging data from each application of the NMR pulse sequence according to whether the data was acquired during the period of high blood velocity or a period of low blood velocity of the corresponding heart beat cycle; accumulating weighted imaging data from a plurality of NMR pulse sequences corresponding to high blood velocity periods and from a plurality of NMR pulse sequences corresponding to low blood velocity periods; subtracting the weighted imaging data corresponding to each specific phase encoding acquired during the high blood velocity periods from the weighted imaging data for the same phase encoding corresponding to low blood velocity periods in order to compute blood vessel imaging data; and forming an image of the blood vessels of interest from the blood vessel imaging data

  19. Fish freshness estimation using eye image processing under white and UV lightings

    Science.gov (United States)

    Kanamori, Katsuhiro; Shirataki, Yuri; Liao, Qiuhong; Ogawa, Yuichi; Suzuki, Tetsuhito; Kondo, Naoshi

    2017-05-01

    A non-destructive method of estimating the freshness of fish is required for appropriate price setting and food safety. In particular, for determining the possibility of eating raw fish (sashimi), freshness estimation is critical. We studied such an estimation method by capturing images of fish eyes and performing image processing using the temporal changes of the luminance of pupil and iris. To detect subtle non-visible changes of these features, we used UV (375 nm) light illumination in addition to visible white light illumination. Polarization and two-channel LED techniques were used to remove strong specular reflection from the cornea of the eye and from clear-plastic wrap used to cover the fish to maintain humidity. Pupil and iris regions were automatically detected separately by image processing after the specular reflection removal process, and two types of eye contrast were defined as the ratio of mean and median pixel values of each region. Experiments using 16 Japanese dace (Tribolodon hakonensis) at 23° and 85% humidity for 24 hours were performed. The eye contrast of raw fish increase non-linearly in the initial period and then decreased; however, that of frozen-thawed fish decreased linearly throughout 24 hours, regardless of the lighting. Interestingly, the eye contrast using UV light showed a higher correlation with time than that using white light only in the case of raw fish within the early 6- hour period postmortem. These results show the possibility of estimating fish freshness in the initial stage when fish are eaten raw using white and UV lightings.

  20. Magnetic particle imaging of blood coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Murase, Kenya, E-mail: murase@sahs.med.osaka-u.ac.jp; Song, Ruixiao; Hiratsuka, Samu [Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Graduate School of Medicine, Osaka University, Osaka 565-0871 (Japan)

    2014-06-23

    We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.

  1. Evaluation of blood signal in cardiac MR imaging using ''black-blood'' technique

    International Nuclear Information System (INIS)

    Nakanishi, Tadashi; Yamada, Takayuki; Tamura, Akihisa; Miyasaka, Kenji; Kohata, Minako; Ono, Chiaki; Kajima, Toshio; Ito, Katsuhide

    1999-01-01

    Degradation of image quality encountered in cardiac imaging has been attributed to flowing blood signal in the ventricular cavity. To solve this problem, a sequence in which a pair of selective and non-selective inversion pulse in used for a preparation pulse, has been proposed. However, even with this sequence we frequently observed the signal in the blood pool caused by blood itself rather than blood flow. In this article, we investigated the characteristics of those signals. Five healthy normal volunteers and 13 patients with ischemic heart disease were scanned with a 1.5-tesla MR imager. Breath-hold ECG gated fast spin echo with the pair of inversion pulses was performed to obtain cardiac images with T 2 contrast. Typical blood signal appeared as inhomogeneous high intense band adjacent to inner surface of left ventricular apex. At ventricular base, no such signal was encountered even at akinetic myocardium in patients with old myocardial infarction. This signal was observed in all volunteers and 39% of patients. Decrease of TR resulting from tachycardia tended to reduce the blood signal in the left ventricular cavity. Thicker slice section and selective inversion pulse tended to increase the blood signal. Recognition of the signal is essential to differentiate true myocardial infarcts from blood signal, although bright blood imaging like gradient echo or thinner section can partly be helpful. (author)

  2. Prediction of pH of fresh chicken breast fillets by VNIR hyperspectral imaging

    Science.gov (United States)

    Visible and near-infrared (VNIR) hyperspectral imaging (400–900 nm) was used to evaluate pH of fresh chicken breast fillets (pectoralis major muscle) from the bone (dorsal) side of individual fillets. After the principal component analysis (PCA), a band threshold method was applied to the first prin...

  3. Images of Blood in American Cinema

    DEFF Research Database (Denmark)

    Rødje, Kjetil

    Through studying images of blood in film from the mid-1950s to the end of the 1960s, this path-breaking book explores how blood as an (audio)visual cinematic element went from predominately operating as a signifier, providing audiences with information about a film’s plot and characters, to incre......Through studying images of blood in film from the mid-1950s to the end of the 1960s, this path-breaking book explores how blood as an (audio)visual cinematic element went from predominately operating as a signifier, providing audiences with information about a film’s plot and characters...... by following one (audio)visual element through an exploration that traverses established standards for film production and reception. This study does not heed distinctions regarding to genres (horror, western, gangster) or models of film production (exploitation, independent, studio productions) but rather...... images as well as with audiences....

  4. Pulsed terahertz imaging of breast cancer in freshly excised murine tumors

    Science.gov (United States)

    Bowman, Tyler; Chavez, Tanny; Khan, Kamrul; Wu, Jingxian; Chakraborty, Avishek; Rajaram, Narasimhan; Bailey, Keith; El-Shenawee, Magda

    2018-02-01

    This paper investigates terahertz (THz) imaging and classification of freshly excised murine xenograft breast cancer tumors. These tumors are grown via injection of E0771 breast adenocarcinoma cells into the flank of mice maintained on high-fat diet. Within 1 h of excision, the tumor and adjacent tissues are imaged using a pulsed THz system in the reflection mode. The THz images are classified using a statistical Bayesian mixture model with unsupervised and supervised approaches. Correlation with digitized pathology images is conducted using classification images assigned by a modal class decision rule. The corresponding receiver operating characteristic curves are obtained based on the classification results. A total of 13 tumor samples obtained from 9 tumors are investigated. The results show good correlation of THz images with pathology results in all samples of cancer and fat tissues. For tumor samples of cancer, fat, and muscle tissues, THz images show reasonable correlation with pathology where the primary challenge lies in the overlapping dielectric properties of cancer and muscle tissues. The use of a supervised regression approach shows improvement in the classification images although not consistently in all tissue regions. Advancing THz imaging of breast tumors from mice and the development of accurate statistical models will ultimately progress the technique for the assessment of human breast tumor margins.

  5. Successful implementation of a packed red blood cell and fresh frozen plasma transfusion protocol in the surgical intensive care unit.

    Directory of Open Access Journals (Sweden)

    Benjamin E Szpila

    Full Text Available Blood product transfusions are associated with increased morbidity and mortality. The purpose of this study was to determine if implementation of a restrictive protocol for packed red blood cell (PRBC and fresh frozen plasma (FFP transfusion safely reduces blood product utilization and costs in a surgical intensive care unit (SICU.We performed a retrospective, historical control analysis comparing before (PRE and after (POST implementation of a restrictive PRBC/FFP transfusion protocol for SICU patients. Univariate analysis was utilized to compare patient demographics and blood product transfusion totals between the PRE and POST cohorts. Multivariate logistic regression models were developed to determine if implementation of the restrictive transfusion protocol is an independent predictor of adverse outcomes after controlling for age, illness severity, and total blood products received.829 total patients were included in the analysis (PRE, n=372; POST, n=457. Despite higher mean age (56 vs. 52 years, p=0.01 and APACHE II scores (12.5 vs. 11.2, p=0.006, mean units transfused per patient were lower for both packed red blood cells (0.7 vs. 1.2, p=0.03 and fresh frozen plasma (0.3 vs. 1.2, p=0.007 in the POST compared to the PRE cohort, respectively. There was no difference in inpatient mortality between the PRE and POST cohorts (7.5% vs. 9.2%, p=0.39. There was a decreased risk of urinary tract infections (OR 0.47, 95%CI 0.28-0.80 in the POST cohort after controlling for age, illness severity and amount of blood products transfused.Implementation of a restrictive transfusion protocol can effectively reduce blood product utilization in critically ill surgical patients with no increase in morbidity or mortality.

  6. High-speed imaging of blood splatter patterns

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.E.; Albright, K.A.; King, N.S.P.; Yates, G.J. (Los Alamos National Lab., NM (United States)); Levine, G.F. (California Dept. of Justice, Sacramento, CA (United States). Bureau of Forensic Services)

    1993-01-01

    The interpretation of blood splatter patterns is an important element in reconstructing the events and circumstances of an accident or crime scene. Unfortunately, the interpretation of patterns and stains formed by blood droplets is not necessarily intuitive and study and analysis are required to arrive at a correct conclusion. A very useful tool in the study of blood splatter patterns is high-speed photography. Scientists at the Los Alamos National Laboratory, Department of Energy (DOE), and Bureau of Forensic Services, State of California, have assembled a high-speed imaging system designed to image blood splatter patterns. The camera employs technology developed by Los Alamos for the underground nuclear testing program and has also been used in a military mine detection program. The camera uses a solid-state CCD sensor operating at approximately 650 frames per second (75 MPixels per second) with a microchannel plate image intensifier that can provide shuttering as short as 5 ns. The images are captured with a laboratory high-speed digitizer and transferred to an IBM compatible PC for display and hard copy output for analysis. The imaging system is described in this paper.

  7. High-speed imaging of blood splatter patterns

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.E.; Albright, K.A.; King, N.S.P.; Yates, G.J. [Los Alamos National Lab., NM (United States); Levine, G.F. [California Dept. of Justice, Sacramento, CA (United States). Bureau of Forensic Services

    1993-05-01

    The interpretation of blood splatter patterns is an important element in reconstructing the events and circumstances of an accident or crime scene. Unfortunately, the interpretation of patterns and stains formed by blood droplets is not necessarily intuitive and study and analysis are required to arrive at a correct conclusion. A very useful tool in the study of blood splatter patterns is high-speed photography. Scientists at the Los Alamos National Laboratory, Department of Energy (DOE), and Bureau of Forensic Services, State of California, have assembled a high-speed imaging system designed to image blood splatter patterns. The camera employs technology developed by Los Alamos for the underground nuclear testing program and has also been used in a military mine detection program. The camera uses a solid-state CCD sensor operating at approximately 650 frames per second (75 MPixels per second) with a microchannel plate image intensifier that can provide shuttering as short as 5 ns. The images are captured with a laboratory high-speed digitizer and transferred to an IBM compatible PC for display and hard copy output for analysis. The imaging system is described in this paper.

  8. Two-photon excited autofluorescence imaging of freshly isolated frog retinas.

    Science.gov (United States)

    Lu, Rong-Wen; Li, Yi-Chao; Ye, Tong; Strang, Christianne; Keyser, Kent; Curcio, Christine A; Yao, Xin-Cheng

    2011-06-01

    The purpose of this study was to investigate cellular sources of autofluorescence signals in freshly isolated frog (Rana pipiens) retinas. Equipped with an ultrafast laser, a laser scanning two-photon excitation fluorescence microscope was employed for sub-cellular resolution examination of both sliced and flat-mounted retinas. Two-photon imaging of retinal slices revealed autofluorescence signals over multiple functional layers, including the photoreceptor layer (PRL), outer nuclear layer (ONL), outer plexiform layer (OPL), inner nuclear layer (INL), inner plexiform layer (IPL), and ganglion cell layer (GCL). Using flat-mounted retinas, depth-resolved imaging of individual retinal layers further confirmed multiple sources of autofluorescence signals. Cellular structures were clearly observed at the PRL, ONL, INL, and GCL. At the PRL, the autofluorescence was dominantly recorded from the intracellular compartment of the photoreceptors; while mixed intracellular and extracellular autofluorescence signals were observed at the ONL, INL, and GCL. High resolution autofluorescence imaging clearly revealed mosaic organization of rod and cone photoreceptors; and sub-cellular bright autofluorescence spots, which might relate to connecting cilium, was observed in the cone photoreceptors only. Moreover, single-cone and double-cone outer segments could be directly differentiated.

  9. Red blood cell image enhancement techniques for cells with ...

    African Journals Online (AJOL)

    quality or challenging conditions of the images such as poor illumination of blood smear and most importantly overlapping RBC. The algorithm comprises of two RBC segmentation that can be selected based on the image quality, circle mask technique and grayscale blood smear image processing. Detail explanations ...

  10. Prevention of ligneous conjunctivitis by topical and subconjunctival fresh frozen plasma.

    Science.gov (United States)

    Tabbara, Khalid F

    2004-08-01

    To present a case of ligneous conjunctivitis where the recurrence of membranous conjunctivitis was prevented by subconjunctival and topical instillation of fresh frozen plasma. Interventional case report. A case of ligneous conjunctivitis with multiple recurrences since the age of 3 years developed recurrent membranous conjunctivitis after transconjunctival levator recession. Blood plasminogen activity was determined. The membrane was excised, and the membrane reappeared 4 days later. The patient was treated with excision of the membrane and subconjunctival injection of fresh frozen plasma and topical fresh frozen plasma. Plasminogen activity of the fresh frozen plasma was normal. Plasminogen blood functional activity was 52% (normal is 80%-120%). The patient had complete remission with no recurrences of membranous conjunctivitis after topical and subconjunctival fresh frozen plasma. Prophylactic use of topical and subconjunctival fresh frozen plasma may help in the prevention of membranes in susceptible patients with plasminogen deficiency.

  11. Brain magnetic resonance imaging with contrast dependent on blood oxygenation

    International Nuclear Information System (INIS)

    Ogawa, S.; Lee, T.M.; Kay, A.R.; Tank, D.W.

    1990-01-01

    Paramagnetic deoxyhemoglobin in venous blood is a naturally occurring contrast agent for magnetic resonance imaging (MRI). By accentuating the effects of this agent through the use of gradient-echo techniques in high yields, the authors demonstrate in vivo images of brain microvasculature with image contrast reflecting the blood oxygen level. This blood oxygenation level-dependent (BOLD) contrast follows blood oxygen changes induced by anesthetics, by insulin-induced hypoglycemia, and by inhaled gas mixtures that alter metabolic demand or blood flow. The results suggest that BOLD contrast can be used to provide in vivo real-time maps of blood oxygenation in the brain under normal physiological conditions. BOLD contrast adds an additional feature to magnetic resonance imaging and complement other techniques that are attempting to provide position emission tomography-like measurements related to regional neural activity

  12. Intelligent Fish Freshness Assessment

    Directory of Open Access Journals (Sweden)

    Hamid Gholam Hosseini

    2008-01-01

    Full Text Available Fish species identification and automated fish freshness assessment play important roles in fishery industry applications. This paper describes a method based on support vector machines (SVMs to improve the performance of fish identification systems. The result is used for the assessment of fish freshness using artificial neural network (ANN. Identification of the fish species involves processing of the images of fish. The most efficient features were extracted and combined with the down-sampled version of the images to create a 1D input vector. Max-Win algorithm applied to the SVM-based classifiers has enhanced the reliability of sorting to 96.46%. The realisation of Cyranose 320 Electronic nose (E-nose, in order to evaluate the fish freshness in real-time, is experimented. Intelligent processing of the sensor patterns involves the use of a dedicated ANN for each species under study. The best estimation of freshness was provided by the most sensitive sensors. Data was collected from four selected species of fishes over a period of ten days. It was concluded that the performance can be increased using individual trained ANN for each specie. The proposed system has been successful in identifying the number of days after catching the fish with an accuracy of up to 91%.

  13. Visible and Near-Infrared Hyperspectral Imaging for Cooking Loss Classification of Fresh Broiler Breast Fillets

    Directory of Open Access Journals (Sweden)

    Hongzhe Jiang

    2018-02-01

    Full Text Available Cooking loss (CL is a critical quality attribute directly relating to meat juiciness. The potential of the hyperspectral imaging (HSI technique was investigated for non-invasively classifying and visualizing the CL of fresh broiler breast meat. Hyperspectral images of total 75 fresh broiler breast fillets were acquired by the system operating in the visible and near-infrared (VNIR, 400–1000 nm range. Mean spectra were extracted from regions of interest (ROIs determined by pure muscle tissue pixels. CL was firstly measured by calculating the weight loss in cooking, and then fillets were grouped into high-CL and low-CL according to the threshold of 20%. The classification methods partial least square-discriminant analysis (PLS-DA and radial basis function-support vector machine (RBF-SVM were applied, respectively, to determine the optimal spectral calibration strategy. Results showed that the PLS-DA model developed using the data, that is, first-order derivative (Der1 of VNIR full spectra, performed best with correct classification rates (CCRs of 0.90 and 0.79 for the calibration and prediction sets, respectively. Furthermore, to simplify the optimal PLS-DA model and make it practical, effective wavelengths were individually selected using uninformative variable elimination (UVE and competitive adaptive reweighted sampling (CARS. Through performance comparison, the CARS-PLS-DA combination was identified as the optimal method and the PLS-DA model built with 18 informative wavelengths selected by CARS resulted in good CCRs of 0.86 and 0.79. Finally, classification maps were created by predicting CL categories of each pixel in the VNIR hyperspectral images using the CARS-PLS-DA model, and the general CL categories of fillets were readily discernible. The overall results were encouraging and showed the promising potential of the VNIR HSI technique for classifying fresh broiler breast fillets into different CL categories.

  14. White blood cell counting analysis of blood smear images using various segmentation strategies

    Science.gov (United States)

    Safuan, Syadia Nabilah Mohd; Tomari, Razali; Zakaria, Wan Nurshazwani Wan; Othman, Nurmiza

    2017-09-01

    In white blood cell (WBC) diagnosis, the most crucial measurement parameter is the WBC counting. Such information is widely used to evaluate the effectiveness of cancer therapy and to diagnose several hidden infection within human body. The current practice of manual WBC counting is laborious and a very subjective assessment which leads to the invention of computer aided system (CAS) with rigorous image processing solution. In the CAS counting work, segmentation is the crucial step to ensure the accuracy of the counted cell. The optimal segmentation strategy that can work under various blood smeared image acquisition conditions is remain a great challenge. In this paper, a comparison between different segmentation methods based on color space analysis to get the best counting outcome is elaborated. Initially, color space correction is applied to the original blood smeared image to standardize the image color intensity level. Next, white blood cell segmentation is performed by using combination of several color analysis subtraction which are RGB, CMYK and HSV, and Otsu thresholding. Noises and unwanted regions that present after the segmentation process is eliminated by applying a combination of morphological and Connected Component Labelling (CCL) filter. Eventually, Circle Hough Transform (CHT) method is applied to the segmented image to estimate the number of WBC including the one under the clump region. From the experiment, it is found that G-S yields the best performance.

  15. A comparison of positron-emitting blood pool imaging agents

    International Nuclear Information System (INIS)

    Hnatowich, D.J.; Kulprathipanja, S.; Evans, G.; Elmaleh, D.

    1979-01-01

    The three agents, 11 C-carboxyhaemoglobin, 68 Ga-transferrin and 68 Ga-labelled red cells have been compared in dogs to assess their relative merits for blood-pool imaging. For 1 h following administration of each agent, periodic blood samples were withdrawn for counting in a NaI (Tl) well counter while conventional two-dimensional images were obtained simultaneously on the Massachusetts General Hospital positron camera. Count rates in regions about the heart, liver and spleen were obtained for each image. The disappearance of blood activity as shown from the results of counting the blood samples and from the counting rates in regions about the heart was found to be identical within experimental error for the three agents. In the liver and spleen regions, the highest count rates were obtained with 68 Ga-transferrin and the lowest with 68 Ga-labelled red cells; count rates in these regions with labelled red cells were virtually constant throughout the 1 h study. It may be concluded that with the exceptions noted above, the three agents are approximately equivalent for blood-pool imaging. (author)

  16. Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection

    International Nuclear Information System (INIS)

    Rahmer, J; Gleich, B; Borgert, J; Antonelli, A; Sfara, C; Magnani, M; Tiemann, B; Weizenecker, J

    2013-01-01

    Magnetic particle imaging (MPI) is a new medical imaging approach that is based on the nonlinear magnetization response of super-paramagnetic iron oxide nanoparticles (SPIOs) injected into the blood stream. To date, real-time MPI of the bolus passage of an approved MRI SPIO contrast agent injected into the tail vein of living mice has been demonstrated. However, nanoparticles are rapidly removed from the blood stream by the mononuclear phagocyte system. Therefore, imaging applications for long-term monitoring require the repeated administration of bolus injections, which complicates quantitative comparisons due to the temporal variations in concentration. Encapsulation of SPIOs into red blood cells (RBCs) has been suggested to increase the blood circulation time of nanoparticles. This work presents first evidence that SPIO-loaded RBCs can be imaged in the blood pool of mice several hours after injection using MPI. This finding is supported by magnetic particle spectroscopy performed to quantify the iron concentration in blood samples extracted from the mice 3 and 24 h after injection of SPIO-loaded RBCs. Based on these results, new MPI applications can be envisioned, such as permanent 3D real-time visualization of the vessel tree during interventional procedures, bleeding monitoring after stroke, or long-term monitoring and treatment control of cardiovascular diseases. (paper)

  17. Toward a patient-based paradigm for blood transfusion.

    Science.gov (United States)

    Farrugia, Albert; Vamvakas, Eleftherios

    2014-01-01

    The current "manufacturing paradigm" of transfusion practice has detached transfusion from the clinical environment. As an example, fresh whole blood in large-volume hemorrhage may be superior to whole blood reconstituted from multiple components. Multicomponent apheresis can overcome logistical difficulties in matching patient needs with fresh component availability and can deliver the benefits of fresh whole blood. Because of the different transfusion needs of patients in emerging economies and the vulnerability of these blood systems to emerging infections, fresh whole blood and multicomponent apheresis can better meet patient needs when compared with transplants of the "manufacturing paradigm". We propose that patient blood management, along with panels of repeat, paid, accredited apheresis and fresh whole-blood donors can be used in emerging economies to support decentralized blood services. This alternative transfusion-medicine paradigm could eventually also be adopted by established economies to focus transfusion medicine on local patient needs and to alleviate the problem of the aging volunteer donor base.

  18. Clinical blood pool MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Leiner, Tim [Maastrich University Medical Center (Netherlands). Dept. of Radiology; Goyen, Martin [University Medical Center Hamburg-Eppendorf (Germany); Rohrer, Mathias [Bayer Schering Pharma AG, Berlin (Germany). European Business Unit Diagnostic Imaging; Schoenberg, Stefan O. (eds.) [University Hospital Mannheim Medical Faculty Mannheim - Heidelberg Univ. (Germany). Dept. of Clinical Radiology and Nuclear Medicine

    2008-07-01

    Clinical Blood Pool MR Imaging - This excellent treatise on Vasovist {sup registered} created by a team of exceptional faculty who are pioneers in MR Angiography covers the basic techniques, safety, efficacy, image processing and pharmaco-economic details to successfully implement a new level of MRA image quality with this new contrast agent. Martin Prince, Cornell University, New York The editors and authors have made groundbreaking contributions towards establishing MR angiography in various investigative settings, rendering it more precise and applying it for diverse indications. The work presented here is founded upon the extensive experience of the editors, as well as the broad range of experience from other scientific working groups. Maximilian Reiser, Ludwig Maximilian University, Munich Vasovist {sup registered} (Gadofosveset), worldwide the first blood pool agent, has only recently become available for clinical use, but has already gained wide acceptance as a tool to improve magnetic resonance angiography. This book presents the first in-depth introduction to the basic physicochemical aspects of the agent, the application of Vasovist {sup registered} in clinical MRA, as well as potential clinical applications beyond MRA and patient management-related aspects. The first part of the book explains basic and technical properties of the agent and the differences of Vasovist {sup registered} compared to currently available extracellular agents. The second part contains detailed chapters on safety and efficacy. In the third part the focus is on MR angiographic applications, and in the fourth part of the book potential clinical fields beyond MRA are explored. All clinical chapters feature ready-to-use clinical protocols and a series of take home messages that concisely summarize the current role of blood pool imaging for each specific indication. (orig.)

  19. IR imaging of blood circulation of patients with vascular disease

    Science.gov (United States)

    Wang, Hsin; Wade, Dwight R., Jr.; Kam, Jack

    2004-04-01

    We conducted a preliminary IR imaging study of blood circulation in patients with peripheral vascular diseases. Abnormal blood flow is common in older adults, especially those with elevated blood lipids, diabetes, hypertension, and a history of smoking. All of these conditions have a high prevalence in our population, often with more than one condition in the same individual. The differences in blood flow is revealed by temperature differences in areas of the extremities as well as other regions of the body. However, what is needed is an imaging technique that is relatively inexpensive and can reveal the blood flow in real time. The IR imaging can show detailed venous system and small tempearture changes associated with blood flow. Six patients with vascular diseases were tested in a clinic set up. Their legs and feet were imaged. We observed large temperature differences (cooling of more than 10° C) at the foot, especially toes. More valuable information were obtained from the temperature distribution maps. IR thermography is potentially a very valuable tool for medical application, especially for vascular diseases.

  20. Identification and red blood cell automated counting from blood smear images using computer-aided system.

    Science.gov (United States)

    Acharya, Vasundhara; Kumar, Preetham

    2018-03-01

    Red blood cell count plays a vital role in identifying the overall health of the patient. Hospitals use the hemocytometer to count the blood cells. Conventional method of placing the smear under microscope and counting the cells manually lead to erroneous results, and medical laboratory technicians are put under stress. A computer-aided system will help to attain precise results in less amount of time. This research work proposes an image-processing technique for counting the number of red blood cells. It aims to examine and process the blood smear image, in order to support the counting of red blood cells and identify the number of normal and abnormal cells in the image automatically. K-medoids algorithm which is robust to external noise is used to extract the WBCs from the image. Granulometric analysis is used to separate the red blood cells from the white blood cells. The red blood cells obtained are counted using the labeling algorithm and circular Hough transform. The radius range for the circle-drawing algorithm is estimated by computing the distance of the pixels from the boundary which automates the entire algorithm. A comparison is done between the counts obtained using the labeling algorithm and circular Hough transform. Results of the work showed that circular Hough transform was more accurate in counting the red blood cells than the labeling algorithm as it was successful in identifying even the overlapping cells. The work also intends to compare the results of cell count done using the proposed methodology and manual approach. The work is designed to address all the drawbacks of the previous research work. The research work can be extended to extract various texture and shape features of abnormal cells identified so that diseases like anemia of inflammation and chronic disease can be detected at the earliest.

  1. 18F-FDG-labeled red blood cell PET for blood-pool imaging: preclinical evaluation in rats.

    Science.gov (United States)

    Matsusaka, Yohji; Nakahara, Tadaki; Takahashi, Kazuhiro; Iwabuchi, Yu; Nishime, Chiyoko; Kajimura, Mayumi; Jinzaki, Masahiro

    2017-12-01

    Red blood cells (RBCs) labeled with single-photon emitters have been clinically used for blood-pool imaging. Although some PET tracers have been introduced for blood-pool imaging, they have not yet been widely used. The present study investigated the feasibility of labeling RBCs with 18 F-2-deoxy-2-fluoro-D-glucose ( 18 F-FDG) for blood-pool imaging with PET. RBCs isolated from venous blood of rats were washed with glucose-free phosphate-buffered saline and labeled with 18 F-FDG. To optimize labeling efficiency, the effects of glucose deprivation time and incubation (labeling) time with 18 F-FDG were investigated. Post-labeling stability was assessed by calculating the release fraction of radioactivity and identifying the chemical forms of 18 F in the released and intracellular components of 18 F-FDG-labeled RBCs incubated in plasma. Just after intravenous injection of the optimized autologous 18 F-FDG-labeled RBCs, dynamic PET scans were performed to evaluate in vivo imaging in normal rats and intraabdominal bleeding models (temporary and persistent bleeding). The optimal durations of glucose deprivation and incubation (labeling) with 18 F-FDG were 60 and 30 min, respectively. As low as 10% of 18 F was released as the form of 18 F-FDG from 18 F-FDG-labeled RBCs after a 60-min incubation. Dynamic PET images of normal rats showed strong persistence in the cardiovascular system for at least 120 min. In the intraabdominal bleeding models, 18 F-FDG-labeled RBC PET visualized the extravascular blood clearly and revealed the dynamic changes of the extravascular radioactivity in the temporary and persistent bleeding. RBCs can be effectively labeled with 18 F-FDG and used for blood-pool imaging with PET in rats.

  2. Imaging flow cytometry assays for quantifying pigment grade titanium dioxide particle internalization and interactions with immune cells in whole blood.

    Science.gov (United States)

    Hewitt, Rachel E; Vis, Bradley; Pele, Laetitia C; Faria, Nuno; Powell, Jonathan J

    2017-10-01

    Pigment grade titanium dioxide is composed of sub-micron sized particles, including a nanofraction, and is widely utilized in food, cosmetic, pharmaceutical, and biomedical industries. Oral exposure to pigment grade titanium dioxide results in at least some material entering the circulation in humans, although subsequent interactions with blood immune cells are unknown. Pigment grade titanium dioxide is employed for its strong light scattering properties, and this work exploited that attribute to determine whether single cell-particle associations could be determined in immune cells of human whole blood at "real life" concentrations. In vitro assays, initially using isolated peripheral blood mononuclear cells, identified titanium dioxide associated with the surface of, and within, immune cells by darkfield reflectance in imaging flow cytometry. This was confirmed at the population level by side scatter measurements using conventional flow cytometry. Next, it was demonstrated that imaging flow cytometry could quantify titanium dioxide particle-bearing cells, within the immune cell populations of fresh whole blood, down to titanium dioxide levels of 10 parts per billion, which is in the range anticipated for human blood following titanium dioxide ingestion. Moreover, surface association and internal localization of titanium dioxide particles could be discriminated in the assays. Overall, results showed that in addition to the anticipated activity of blood monocytes internalizing titanium dioxide particles, neutrophil internalization and cell membrane adhesion also occurred, the latter for both phagocytic and nonphagocytic cell types. What happens in vivo and whether this contributes to activation of one or more of these different cells types in blood merits further attention. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  3. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    Energy Technology Data Exchange (ETDEWEB)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V. (Mt. Sinai Medical Center, New York, NY (USA))

    1989-09-01

    Blood-pool subtraction has been proposed to enhance {sup 111}In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging.

  4. Value of blood-pool subtraction in cardiac indium-111-labeled platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Vallabhajosula, S.; Goldman, M.E.; Goldsmith, S.J.; Palestro, C.; Strashun, A.; Vaquer, R.; Phillips, R.A.; Fuster, V.

    1989-01-01

    Blood-pool subtraction has been proposed to enhance 111 In-labeled platelet imaging of intracardiac thrombi. We tested the accuracy of labeled platelet imaging, with and without blood-pool subtraction, in ten subjects with cardiac thrombi of varying age, eight with endocarditis being treated with antimicrobial therapy and ten normal controls. Imaging was performed early after labeled platelet injection (24 hr or less) and late (48 hr or more). Blood-pool subtraction was carried out. All images were graded subjectively by four experienced, blinded readers. Detection accuracy was measured by the sensitivity at three fixed levels of specificity estimated from receiver operator characteristic curve analysis and tested by three-way analysis of variance. Detection accuracy was generally improved on delayed images. Blood-pool subtraction did not improve accuracy. Although blood-pool subtraction increased detection sensitivity, this was offset by decreased specificity. For this population studied, blood-pool subtraction did not improve subjective detection of abnormal platelet deposition by 111In platelet imaging

  5. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  6. Imaging of the bronchial blood flow using RI-angiography

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Hirayama, Jiro; Kanai, Hisakata; Kobayashi, Toshio; Handa, Kenjiro

    1979-01-01

    RI-angiography with sup(99m)TcO 4 - was carried out using a scintillation camera with a digital minicomputer for the purpose of imaging of bronchial blood flow in various lung diseases, and as application of dual radioisotope techniques, other imagings such as tumor imaging with 197 HgCl 2 or 67 Ga-citrate and/or perfusion imaging with sup(99m)Tc-MAA, were performed simultaneously in patients remaining the same position, too. The image as a iso-count map extracted out of the image of 197 HgCl 2 , 67 Ga-citrate or sup(99m)Tc-MAA, was superimposed to the brightness image of RI-angiogram (aortic phase). By these procedures, the image of bronchial blood flow were obtained in some patients with lung cancer, pulmonary tuberculosis, lung abscess, and chronic bronchitis. The dual radioisotope techniques using RI-angiography and the other imaging were useful to make isotope diagnosis of lung diseases more reliable, and the image superimposition methods using RI-angiogram and the image of tumor of perfusion, were useful to improve anatomic orientation of the former. (author)

  7. Peripheral blood smear image analysis: A comprehensive review

    Directory of Open Access Journals (Sweden)

    Emad A Mohammed

    2014-01-01

    Full Text Available Peripheral blood smear image examination is a part of the routine work of every laboratory. The manual examination of these images is tedious, time-consuming and suffers from interobserver variation. This has motivated researchers to develop different algorithms and methods to automate peripheral blood smear image analysis. Image analysis itself consists of a sequence of steps consisting of image segmentation, features extraction and selection and pattern classification. The image segmentation step addresses the problem of extraction of the object or region of interest from the complicated peripheral blood smear image. Support vector machine (SVM and artificial neural networks (ANNs are two common approaches to image segmentation. Features extraction and selection aims to derive descriptive characteristics of the extracted object, which are similar within the same object class and different between different objects. This will facilitate the last step of the image analysis process: pattern classification. The goal of pattern classification is to assign a class to the selected features from a group of known classes. There are two types of classifier learning algorithms: supervised and unsupervised. Supervised learning algorithms predict the class of the object under test using training data of known classes. The training data have a predefined label for every class and the learning algorithm can utilize this data to predict the class of a test object. Unsupervised learning algorithms use unlabeled training data and divide them into groups using similarity measurements. Unsupervised learning algorithms predict the group to which a new test object belong to, based on the training data without giving an explicit class to that object. ANN, SVM, decision tree and K-nearest neighbor are possible approaches to classification algorithms. Increased discrimination may be obtained by combining several classifiers together.

  8. Images of Blood in American Cinema

    DEFF Research Database (Denmark)

    Rødje, Kjetil

    by following one (audio)visual element through an exploration that traverses established standards for film production and reception. This study does not heed distinctions regarding to genres (horror, western, gangster) or models of film production (exploitation, independent, studio productions) but rather......Through studying images of blood in film from the mid-1950s to the end of the 1960s, this path-breaking book explores how blood as an (audio)visual cinematic element went from predominately operating as a signifier, providing audiences with information about a film’s plot and characters......, to increasingly operating in terms of affect, potentially evoking visceral and embodied responses in viewers. Using films such as The Return of Dracula, The Tingler, Blood Feast, Two Thousand Maniacs, Color Me Blood Red, Bonnie and Clyde, and The Wild Bunch, Rødje takes a novel approach to film history...

  9. Effect of blood glucose level on 18F-FDG PET/CT imaging

    International Nuclear Information System (INIS)

    Tan Haibo; Lin Xiangtong; Guan Yihui; Zhao Jun; Zuo Chuantao; Hua Fengchun; Tang Wenying

    2008-01-01

    Objective: The aim of this study was to investigate the effect of blood glucose level on the image quality of 18 F-fluorodeoxyglucose (FDG) PET/CT imaging. Methods: Eighty patients referred to the authors' department for routine whole-body 18 F-FDG PET/CT check up were recruited into this study. The patients were classified into 9 groups according to their blood glucose level: normal group avg and SUV max ) of liver on different slices. SPSS 12.0 was used to analyse the data. Results: (1) There were significant differences among the 9 groups in image quality scores and image noises (all P avg and SUV max : 0.60 and 0.33, P<0.05). Conclusions: The higher the blood glucose level, the worse the image quality. When the blood glucose level is more than or equal to 12.0 mmol/L, the image quality will significantly degrade. (authors)

  10. Determination of blood cell subtype concentrations from frozen whole blood samples using TruCount beads.

    Science.gov (United States)

    Langenskiöld, Cecilia; Mellgren, Karin; Abrahamsson, Jonas; Bemark, Mats

    2016-06-24

    In many studies it would be advantageous if blood samples could be collected and analyzed using flow cytometry at a later stage. Ideally, sample collection should involve little hands-on time, allow for long-term storage, and minimally influence the samples. Here we establish a flow cytometry antibody panel that can be used to determine granulocytes, monocytes, and lymphocyte subset concentrations in fresh and frozen whole blood using TruCount technology. The panel can be used on fresh whole-blood samples as well as whole-blood samples that have been frozen after mixing with 10% DMSO. Concentrations in frozen and fresh sample is highly correlated both when frozen within 4 h and the day after collection (r ≥ 0.98), and the estimated concentration in frozen samples was between 91 and 94% of that in fresh samples for all cell types. Using this method whole-blood samples can be frozen using a simple preparation method, and stored long-term before accurate determination of cell concentration. This allows for standardized analysis of the samples at a reference laboratory in multi-center studies. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  11. Toward a patient-based paradigm for blood transfusion

    Directory of Open Access Journals (Sweden)

    Farrugia A

    2014-01-01

    Full Text Available Albert Farrugia,1,2 Eleftherios Vamvakas31College of Medicine, Biology and Environment, Australian National University, Acton, ACT, Australia; 2Centre for Orthopaedic Research, Department of Surgery, Faculty of Medicine and Surgery, University of Western Australia, Perth, WA, Australia; 3Cedars-Sinai Medical Center, Los Angeles, CA, USAAbstract: The current "manufacturing paradigm" of transfusion practice has detached transfusion from the clinical environment. As an example, fresh whole blood in large-volume hemorrhage may be superior to whole blood reconstituted from multiple components. Multicomponent apheresis can overcome logistical difficulties in matching patient needs with fresh component availability and can deliver the benefits of fresh whole blood. Because of the different transfusion needs of patients in emerging economies and the vulnerability of these blood systems to emerging infections, fresh whole blood and multicomponent apheresis can better meet patient needs when compared with transplants of the "manufacturing paradigm". We propose that patient blood management, along with panels of repeat, paid, accredited apheresis and fresh whole-blood donors can be used in emerging economies to support decentralized blood services. This alternative transfusion–medicine paradigm could eventually also be adopted by established economies to focus transfusion medicine on local patient needs and to alleviate the problem of the aging volunteer donor base.Keywords: indications, emerging countries, patient blood management

  12. High-resolution ultrasound imaging and noninvasive optoacoustic monitoring of blood variables in peripheral blood vessels

    Science.gov (United States)

    Petrov, Irene Y.; Petrov, Yuriy; Prough, Donald S.; Esenaliev, Rinat O.

    2011-03-01

    Ultrasound imaging is being widely used in clinics to obtain diagnostic information non-invasively and in real time. A high-resolution ultrasound imaging platform, Vevo (VisualSonics, Inc.) provides in vivo, real-time images with exceptional resolution (up to 30 microns) using high-frequency transducers (up to 80 MHz). Recently, we built optoacoustic systems for probing radial artery and peripheral veins that can be used for noninvasive monitoring of total hemoglobin concentration, oxyhemoglobin saturation, and concentration of important endogenous and exogenous chromophores (such as ICG). In this work we used the high-resolution ultrasound imaging system Vevo 770 for visualization of the radial artery and peripheral veins and acquired corresponding optoacoustic signals from them using the optoacoustic systems. Analysis of the optoacoustic data with a specially developed algorithm allowed for measurement of blood oxygenation in the blood vessels as well as for continuous, real-time monitoring of arterial and venous blood oxygenation. Our results indicate that: 1) the optoacoustic technique (unlike pure optical approaches and other noninvasive techniques) is capable of accurate peripheral venous oxygenation measurement; and 2) peripheral venous oxygenation is dependent on skin temperature and local hemodynamics. Moreover, we performed for the first time (to the best of our knowledge) a comparative study of optoacoustic arterial oximetry and a standard pulse oximeter in humans and demonstrated superior performance of the optoacoustic arterial oximeter, in particular at low blood flow.

  13. In-vivo brain blood flow imaging based on laser speckle contrast imaging and synchrotron radiation microangiography

    International Nuclear Information System (INIS)

    Miao, Peng; Feng, Shihan; Zhang, Qi; Lin, Xiaojie; Xie, Bohua; Liu, Chenwei; Yang, Guo-Yuan

    2014-01-01

    Abstract In-vivo imaging of blood flow in the cortex and sub-cortex is still a challenge in biological and pathological studies of cerebral vascular diseases. Laser speckle contrast imaging (LSCI) only provides cortex blood flow information. Traditional synchrotron radiation micro-angiography (SRA) provides sub-cortical vasculature information with high resolution. In this study, a bolus front-tracking method was developed to extract blood flow information based on SRA. Combining LSCI and SRA, arterial blood flow in the ipsilateral cortex and sub-cortex was monitored after experimental intracerebral hemorrhage of mice. At 72 h after injury, a significant blood flow increase was observed in the lenticulostriate artery along with blood flow decrease in cortical branches of the middle cerebral artery. This combined strategy provides a new approach for the investigation of brain vasculature and blood flow changes in preclinical studies. (paper)

  14. 21 CFR 101.95 - “Fresh,” “freshly frozen,” “fresh frozen,” “frozen fresh.”

    Science.gov (United States)

    2010-04-01

    ... freezing will not preclude use of the term “fresh frozen” to describe the food. “Quickly frozen” means... 21 Food and Drugs 2 2010-04-01 2010-04-01 false âFresh,â âfreshly frozen,â âfresh frozen,â âfrozen fresh.â 101.95 Section 101.95 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND...

  15. Image resizing using saliency strength map and seam carving for white blood cell analysis

    Directory of Open Access Journals (Sweden)

    Nam JaeYeal

    2010-09-01

    Full Text Available Abstract Background A new image-resizing method using seam carving and a Saliency Strength Map (SSM is proposed to preserve important contents, such as white blood cells included in blood cell images. Methods To apply seam carving to cell images, a SSM is initially generated using a visual attention model and the structural properties of white blood cells are then used to create an energy map for seam carving. As a result, the energy map maximizes the energies of the white blood cells, while minimizing the energies of the red blood cells and background. Thus, the use of a SSM allows the proposed method to reduce the image size efficiently, while preserving the important white blood cells. Results Experimental results using the PSNR (Peak Signal-to-Noise Ratio and ROD (Ratio of Distortion of blood cell images confirm that the proposed method is able to produce better resizing results than conventional methods, as the seam carving is performed based on an SSM and energy map. Conclusions For further improvement, a faster medical image resizing method is currently being investigated to reduce the computation time, while maintaining the same image quality.

  16. Image resizing using saliency strength map and seam carving for white blood cell analysis.

    Science.gov (United States)

    Ko, ByoungChul; Kim, SeongHoon; Nam, JaeYeal

    2010-09-20

    A new image-resizing method using seam carving and a Saliency Strength Map (SSM) is proposed to preserve important contents, such as white blood cells included in blood cell images. To apply seam carving to cell images, a SSM is initially generated using a visual attention model and the structural properties of white blood cells are then used to create an energy map for seam carving. As a result, the energy map maximizes the energies of the white blood cells, while minimizing the energies of the red blood cells and background. Thus, the use of a SSM allows the proposed method to reduce the image size efficiently, while preserving the important white blood cells. Experimental results using the PSNR (Peak Signal-to-Noise Ratio) and ROD (Ratio of Distortion) of blood cell images confirm that the proposed method is able to produce better resizing results than conventional methods, as the seam carving is performed based on an SSM and energy map. For further improvement, a faster medical image resizing method is currently being investigated to reduce the computation time, while maintaining the same image quality.

  17. Algorithm for detection of overlapped red blood cells in microscopic images of blood smears

    OpenAIRE

    Romero-Rondón, Miguel Fabián; Sanabria-Rosas, Laura Melissa; Bautista-Rozo, Lola Xiomara; Mendoza-Castellanos, Alfonso

    2016-01-01

    The hemogram is one of the most requested medical tests as it presents details about the three cell series in the blood: red series, white series and platelet series. To make some diagnostics, the specialist must undertake the test manually, observing the blood cells under the microscope, which implies a great physical effort. In order to facilitate this work, different digital image processing techniques to detect and classify red blood cells have been proposed. However, a common problem is ...

  18. Investigation of the ripeness of oil palm fresh fruit bunches using bio-speckle imaging

    Science.gov (United States)

    Salambue, R.; Adnan, A.; Shiddiq, M.

    2018-03-01

    The ripeness of the oil palm Fresh Fruit Bunches (FFB) determines the yield of the oil produced. Traditionally there are two ways to determine FFB ripeness which are the number of loose fruits and the color changes. Nevertheless, one drawback of visual determination is subjective and qualitative judgment. In this study, the FFB ripeness was investigated using laser based image processing technique. The advantages of using this technique are non-destructive, simple and quantitative. The working principle of the investigation is that a FFB is inserted into a light tight box which contains a laser diode and a CMOS camera, the FFB is illuminated, and then an image is recorded. The FFB image recorder was performed on four FFB fractions i.e. F0, F3, F4 and F5 on the front and rear surfaces at three sections. The recorded images are speckled granules that have light intensity variation (bio-speckle imaging). The feature extracted from the specked image is the contrast value obtained from the average gray value intensity and the standard deviation. Based on the contrast values, the four fractions of FFB can be grouped into three levels of ripeness of unripe (F0), ripe (F3) and overripe (F4 and F5) on the front surface of base section of FFB by 75%.

  19. Listeria monocytogenes in Fresh Produce: Outbreaks, Prevalence and Contamination Levels

    Directory of Open Access Journals (Sweden)

    Qi Zhu

    2017-03-01

    Full Text Available Listeria monocytogenes, a member of the genus Listeria, is widely distributed in agricultural environments, such as soil, manure and water. This organism is a recognized foodborne pathogenic bacterium that causes many diseases, from mild gastroenteritis to severe blood and/or central nervous system infections, as well as abortion in pregnant women. Generally, processed ready-to-eat and cold-stored meat and dairy products are considered high-risk foods for L. monocytogenes infections that cause human illness (listeriosis. However, recently, several listeriosis outbreaks have been linked to fresh produce contamination around the world. Additionally, many studies have detected L. monocytogenes in fresh produce samples and even in some minimally processed vegetables. Thus L. monocytogenes may contaminate fresh produce if present in the growing environment (soil and water. Prevention of biofilm formation is an important control measure to reduce the prevalence and survival of L. monocytogenes in growing environments and on fresh produce. This article specifically focuses on fresh produce–associated listeriosis outbreaks, prevalence in growing environments, contamination levels of fresh produce, and associated fresh produce safety challenges.

  20. New algorithm for detecting smaller retinal blood vessels in fundus images

    Science.gov (United States)

    LeAnder, Robert; Bidari, Praveen I.; Mohammed, Tauseef A.; Das, Moumita; Umbaugh, Scott E.

    2010-03-01

    About 4.1 million Americans suffer from diabetic retinopathy. To help automatically diagnose various stages of the disease, a new blood-vessel-segmentation algorithm based on spatial high-pass filtering was developed to automatically segment blood vessels, including the smaller ones, with low noise. Methods: Image database: Forty, 584 x 565-pixel images were collected from the DRIVE image database. Preprocessing: Green-band extraction was used to obtain better contrast, which facilitated better visualization of retinal blood vessels. A spatial highpass filter of mask-size 11 was applied. A histogram stretch was performed to enhance contrast. A median filter was applied to mitigate noise. At this point, the gray-scale image was converted to a binary image using a binary thresholding operation. Then, a NOT operation was performed by gray-level value inversion between 0 and 255. Postprocessing: The resulting image was AND-ed with its corresponding ring mask to remove the outer-ring (lens-edge) artifact. At this point, the above algorithm steps had extracted most of the major and minor vessels, with some intersections and bifurcations missing. Vessel segments were reintegrated using the Hough transform. Results: After applying the Hough transform, both the average peak SNR and the RMS error improved by 10%. Pratt's Figure of Merit (PFM) was decreased by 6%. Those averages were better than [1] by 10-30%. Conclusions: The new algorithm successfully preserved the details of smaller blood vessels and should prove successful as a segmentation step for automatically identifying diseases that affect retinal blood vessels.

  1. Fast Blood Vector Velocity Imaging using ultrasound: In-vivo examples of complex blood flow in the vascular system

    DEFF Research Database (Denmark)

    Hansen, Kristoffer Lindskov; Udesen, Jesper; Gran, Fredrik

    2008-01-01

    Conventional ultrasound methods for acquiring color flow images of the blood motion are restricted by a relatively low frame rate and angle dependent velocity estimates. The Plane Wave Excitation (PWE) method has been proposed to solve these limitations. The frame rate can be increased, and the 2-D...... vector velocity of the blood motion can be estimated. The transmitted pulse is not focused, and a full speckle image of the blood can be acquired for each emission. A 13 bit Barker code is transmitted simultaneously from each transducer element. The 2-D vector velocity of the blood is found using 2-D...... speckle tracking between segments in consecutive speckle images. The flow patterns of six bifurcations and two veins were investigated in-vivo. It was shown: 1) that a stable vortex in the carotid bulb was present opposed to other examined bifurcations, 2) that retrograde flow was present...

  2. Three-dimensional visualization of myocardial motion and blood flow with cine-MR images

    International Nuclear Information System (INIS)

    Oshiro, Osamu; Matani, Ayumu; Chihara, Kunihiro; Mikami, Taisei; Kitabatake, Akira.

    1997-01-01

    This paper describes a three-dimensional (3D) reconstruction and presentation method to visualize myocardial motion and blood flow in a heart using cine-MR (magnetic resonance) images. Firstly, the region of myocardium and blood were segmented with certain threshold gray values. Secondly, some slices were interpolated linearly to reconstruct a 3D static image. Finally, a 3D dynamic image was presented with displaying the 3D static images sequentially. The experimental results indicate that this method enables to visualize not only normal but also abnormal blood flow in cine-mode. (author)

  3. Automatic segmentation of blood vessels from retinal fundus images ...

    Indian Academy of Sciences (India)

    The retinal blood vessels were segmented through color space conversion and color channel .... Retinal blood vessel segmentation was also attempted through multi-scale operators. A few works in this ... fundus camera at 35 degrees field of view. The image ... vessel segmentation is available from two human observers.

  4. Application of chlorophyll fluorescence imaging and hyperspectral imaging in evaluation of decay in fresh-cut lettuce

    Science.gov (United States)

    Lettuce (Lactuca sativa L.) is commercially the most popular leafy vegetable whose leaves are usually consumed raw. Cleaned, cored, and chopped (fresh-cut) lettuce is a desirable, but highly perishable product. Modified atmosphere packaging (MAP) has been introduced to maintain quality of fresh-cut ...

  5. Evaluation on the imaging of the bronchial blood flow using nuclear angiocardiography

    International Nuclear Information System (INIS)

    Fujii, Tadashige; Hirayama, Jiro; Kanai, Hisakata; Kobayashi, Toshio; Handa, Kenjiro

    1979-01-01

    Nuclear angiocardiography with sup(99m)TcO 4 - was performed for the purpose of the delineation of the systemic perfusion in various lung diseases, using a scintillation camera with a digital minicomputer system. The images of the bronchial blood flow were obtained in cases with primary lung cancer, pulmonary tuberculosis, lung abscess, bronchiectasis and chronic bronchitis. The fair images of the bronchial blood flow were taken in cases of peripheral type, adenocarcinoma and primary foci of atelectatic type in primary lung cancer. The grade of delineation of the bronchial blood flow and vascularity of bronchial artery in foci of primary lung cancer were correlative to the grade of accumulation of 197 HgCl 2 , respectively. The joint use of nuclear angiocardiography and other imagings such as tumor or perfusion one was useful for evaluation of the pulmonary and systemic circulation, and that made isotope diagnosis of primary lung cancer more reliable too. The image as a isocount map extracted out of the image of 197 HgCl 2 or sup(99m)Tc-MAA, was superimposed to the brightness image of the nuclear angiocardiogram (aortic phase). This image superimposition methods were valuable to improve anatomic orientation of the nuclear angiocardiogram. The delineation of the bronchial blood flow on the subtraction image, which obtained from the two time-different images in aortic phase of the nuclear angiocardiogram, was better than that of the original images. (author)

  6. The values of myocardial tomography imaging and gated cardiac blood pool imaging in detecting left ventricular aneurysm

    International Nuclear Information System (INIS)

    Zhu Mei; Pan Zhongyun; Li Jinhui

    1992-01-01

    The sensitivity and specificity of myocardial tomography imaging and gated cardiac blood-pool imaging in detecting LVA were studied in 36 normal subjects and 68 patients with myocardial infarction. The sensitivities of exercise and rest myocardial imaging in detecting LVA were 85% and 77.3% respectively. The specificity of both is 95.5%. The sensitivity of cinema display, phase analysis and left ventricular phase shift in evaluating LVA were 86.7%, 86.7%, 100% respectively. Their specificity were all 100%. It is concluded that blood pool imaging is of choice for the diagnosis of LVA, and that myocardial imaging could also demonstrate LVA during diagnosing myocardial infarction

  7. Automatic segmentation of blood vessels from retinal fundus images ...

    Indian Academy of Sciences (India)

    The retinal blood vessels were segmented through color space conversion and color channel extraction, image pre-processing, Gabor filtering, image postprocessing, feature construction through application of principal component analysis, k-means clustering and first level classification using Naïve–Bayes classification ...

  8. Laser speckle contrast imaging of skin blood perfusion responses induced by laser coagulation

    Energy Technology Data Exchange (ETDEWEB)

    Ogami, M; Kulkarni, R; Wang, H; Reif, R; Wang, R K [University of Washington, Department of Bioengineering, Seattle, Washington 98195 (United States)

    2014-08-31

    We report application of laser speckle contrast imaging (LSCI), i.e., a fast imaging technique utilising backscattered light to distinguish such moving objects as red blood cells from such stationary objects as surrounding tissue, to localise skin injury. This imaging technique provides detailed information about the acute perfusion response after a blood vessel is occluded. In this study, a mouse ear model is used and pulsed laser coagulation serves as the method of occlusion. We have found that the downstream blood vessels lacked blood flow due to occlusion at the target site immediately after injury. Relative flow changes in nearby collaterals and anastomotic vessels have been approximated based on differences in intensity in the nearby collaterals and anastomoses. We have also estimated the density of the affected downstream vessels. Laser speckle contrast imaging is shown to be used for highresolution and fast-speed imaging for the skin microvasculature. It also allows direct visualisation of the blood perfusion response to injury, which may provide novel insights to the field of cutaneous wound healing. (laser biophotonics)

  9. Laser speckle contrast imaging of skin blood perfusion responses induced by laser coagulation

    Science.gov (United States)

    Ogami, M.; Kulkarni, R.; Wang, H.; Reif, R.; Wang, R. K.

    2014-08-01

    We report application of laser speckle contrast imaging (LSCI), i.e., a fast imaging technique utilising backscattered light to distinguish such moving objects as red blood cells from such stationary objects as surrounding tissue, to localise skin injury. This imaging technique provides detailed information about the acute perfusion response after a blood vessel is occluded. In this study, a mouse ear model is used and pulsed laser coagulation serves as the method of occlusion. We have found that the downstream blood vessels lacked blood flow due to occlusion at the target site immediately after injury. Relative flow changes in nearby collaterals and anastomotic vessels have been approximated based on differences in intensity in the nearby collaterals and anastomoses. We have also estimated the density of the affected downstream vessels. Laser speckle contrast imaging is shown to be used for highresolution and fast-speed imaging for the skin microvasculature. It also allows direct visualisation of the blood perfusion response to injury, which may provide novel insights to the field of cutaneous wound healing.

  10. Hemostatic resuscitation for massive hemorrhage with warm fresh whole blood in a patient with severe blunt trauma

    Directory of Open Access Journals (Sweden)

    Yuan-Hao Liu

    2014-10-01

    Full Text Available A 24-year-old male Navy soldier was struck on the left thigh by a ruptured cable and was subsequently thrown into the sea. Initial evaluation showed an Injury Severity Score of 34. Core body temperature was 34.1°C. Laboratory data included a hemoglobin level of 4.5 g/dL and a hematocrit of 13.3%. Prothrombin time was prolonged (>100 seconds, international normalized ratio was elevated (9.99, and partial thromboplastin time was elevated (>180 seconds. The patient was treated for hypothermia, coagulopathy, and metabolic acidosis during resuscitation. The patient was transfused with 16,320 mL of blood during the first 24 hours following the accident, including 4500 mL (18 units of warm fresh whole blood (WFWB donated by the patient's military colleagues. The patient was successfully resuscitated, and the injured leg was salvaged. Component therapy can afford replacement of specific deficiencies or requirements, decrease the risk of transfusion-transmitted infectious diseases, and improve resource utilization. However, a protocol of early transfusion with WFWB should be considered during resuscitation following massive hemorrhage in specific conditions such as battle fields or urgent situations.

  11. Splitting blood and blood product packaging reduces donor exposure for patients undergoing cardiopulmonary bypass.

    Science.gov (United States)

    Nuszkowski, M M; Jonas, R A; Zurakowski, D; Deutsch, N

    2015-11-01

    Cardiopulmonary bypass for congenital heart surgery requires packed red cells (PRBC) and fresh frozen plasma (FFP) to be available, both for priming of the circuit as well as to replace blood loss. This study examines the hypothesis that splitting one unit of packed red blood cells and one unit of fresh frozen plasma into two half units reduces blood product exposure and wastage in the Operating Room. Beginning August 2013, the blood bank at Children's National Medical Center began splitting one unit of packed red blood cells (PRBC) and one unit of fresh frozen plasma (FFP) for patients undergoing cardiopulmonary bypass (CPB). The 283 patients who utilized CPB during calendar year 2013 were divided into 2 study groups: before the split and after the split. The principal endpoints were blood product usage and donor exposure intra-operatively and within 72 hours post-operatively. There was a significant decrease in median total donor exposures for FFP and cryoprecipitate from 5 to 4 per case (p = 0.007, Mann-Whitney U-test). However, there was no difference in the volume of blood and blood products used; in fact, there was a significant increase in the amount of FFP that was wasted with the switch to splitting the unit of FFP. We found that modification of blood product packaging can decrease donor exposure. Future investigation is needed as to how to modify packaging to minimize wastage. © The Author(s) 2015.

  12. Adaptive and automatic red blood cell counting method based on microscopic hyperspectral imaging technology

    Science.gov (United States)

    Liu, Xi; Zhou, Mei; Qiu, Song; Sun, Li; Liu, Hongying; Li, Qingli; Wang, Yiting

    2017-12-01

    Red blood cell counting, as a routine examination, plays an important role in medical diagnoses. Although automated hematology analyzers are widely used, manual microscopic examination by a hematologist or pathologist is still unavoidable, which is time-consuming and error-prone. This paper proposes a full-automatic red blood cell counting method which is based on microscopic hyperspectral imaging of blood smears and combines spatial and spectral information to achieve high precision. The acquired hyperspectral image data of the blood smear in the visible and near-infrared spectral range are firstly preprocessed, and then a quadratic blind linear unmixing algorithm is used to get endmember abundance images. Based on mathematical morphological operation and an adaptive Otsu’s method, a binaryzation process is performed on the abundance images. Finally, the connected component labeling algorithm with magnification-based parameter setting is applied to automatically select the binary images of red blood cell cytoplasm. Experimental results show that the proposed method can perform well and has potential for clinical applications.

  13. Imaging experimental infective endocarditis with indium-111-labeled blood cellular components

    International Nuclear Information System (INIS)

    Riba, A.L.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1979-01-01

    The capability of radionuclide imaging to detect experimental aortic valve infective endocarditis was assessed with indium-111 ( 111 In)-labeled blood cells. Sequential cardiac imaging and tissue distribution studies were obtained in 17 rabbits with infective endocarditis after administration of 111 In-platelets and in five after 111 In-polymorphonuclear leukocytes. Forty-eight to 72 hours after platelet administration, in vivo imaging demonstrated abnormal 111 In uptake in all animals in the region of the aortic valve in an anatomically distinct pattern. Images of the excised heart showed discrete cardiac uptake conforming to the in vivo image and gross pathological examination. 111 In-platelet uptake in vegetations from the 17 animals averaged 240 +- 41 times greater than that in normal myocardium and 99 +- 15 times greater uptake in blood. In contrast, 111 In-leukocyte cardiac imaging showed no abnormal aortic valve uptake 24 hours after tracer administration and the lesion myocardium activity ratio was only 5 +- 2 (3 +- 1 for lesion/blood activity). Four normal rabbits demonstrated neither positive 111 In-platelet scintigraphs nor abnormal cardiac tissue uptake. Likewise, noncellular 111 In was not concentrated to any significant extent in three animals with infective endocarditis. This study demonstrates that 111 In-platelet, but not leukocyte cardiac imaging, is a sensitive technique for detecting experimental infective endocarditis. The imaging data conform to the cellular pathology of the infective endocarditis vegetation

  14. The value of thyroid blood flow and static imaging for diagnosis of hashimotos disease

    International Nuclear Information System (INIS)

    Song Bangkun; Yang Jishen; Shen Dawei; Liu Bin; Xue Yuanming; Shi Jue

    1995-01-01

    The diagnostic value of the combination of thyroid blood flow and static imaging for Hashimotos disease are evaluated. Both thyroid blood flow and static imaging with 99m Tc was carried out in 108 Hashimotos disease proved by fine needle biopsy. 87% of them had markedly or slightly increased thyroid blood flow. On static imaging 89.8% showed active nonuniformity, among them, 16.7% was cold nodules. The 99m Tc uptake was normal in 66 (58.3%), decreased in 26 (26.9%), but only increased in 16, in them 4 accompanying hyperthyroidism. Thyroid blood flow and static imaging, a simple and convenient approach, combining with radioimmunoassay and clinical manifestation, can be used as routine diagnostic model

  15. Comparison of platelet transfusion as fresh whole blood versus apheresis platelets for massively transfused combat trauma patients (CME).

    Science.gov (United States)

    Perkins, Jeremy G; Cap, Andrew P; Spinella, Philip C; Shorr, Andrew F; Beekley, Alec C; Grathwohl, Kurt W; Rentas, Francisco J; Wade, Charles E; Holcomb, John B

    2011-02-01

    At major combat hospitals, the military is able to provide blood products to include apheresis platelets (aPLT), but also has extensive experience using fresh whole blood (FWB). In massively transfused trauma patients, we compared outcomes of patients receiving FWB to those receiving aPLT. This study was a retrospective review of casualties at the military hospital in Baghdad, Iraq, between January 2004 and December 2006. Patients requiring massive transfusion (≥10 units in 24 hr) were divided into two groups: those receiving FWB (n = 85) or aPLT (n = 284) during their resuscitation. Admission characteristics, resuscitation, and survival were compared between groups. Multivariate regression analyses were performed comparing survival of patients at 24 hours and at 30 days. Secondary outcomes including adverse events and causes of death were analyzed. Unadjusted survival between groups receiving aPLT and FWB was similar at 24 hours (84% vs. 81%, respectively; p = 0.52) and at 30 days (60% versus 57%, respectively; p = 0.72). Multivariate regression failed to identify differences in survival between patients receiving PLT transfusions either as FWB or as aPLT at 24 hours or at 30 days. Survival for massively transfused trauma patients receiving FWB appears to be similar to patients resuscitated with aPLT. Prospective trials will be necessary before consideration of FWB in the routine management of civilian trauma. However, in austere environments where standard blood products are unavailable, FWB is a feasible alternative. © 2010 American Association of Blood Banks.

  16. Multi-modal in vivo imaging of brain blood oxygenation, blood flow and neural calcium dynamics during acute seizures

    Science.gov (United States)

    Ringuette, Dene; Jeffrey, Melanie A.; Carlen, Peter L.; Levi, Ofer

    2016-03-01

    Dysfunction of the vascular endothelium has been implicated in the development of epilepsy. To better understand the relation between vascular function and seizure and provide a foundation for interpreting results from functional imaging in chronic disease models, we investigate the relationship between intracellular calcium dynamics and local cerebral blood flow and blood oxygen saturation during acute seizure-like events and pharmacological seizure rescue. To probe the relation between the aforementioned physiological markers in an acute model of epilepsy in rats, we integrated three different optical modalities together with electrophysiological recordings: Laser speckle contrast imaging (LSCI) was used to study changes in flow speeds, Intrinsic optical signal imaging (IOSI) was used to monitor changes in oxygenated, de-oxygenated, and total hemoglobin concentration, and Calcium-sensitive dye imaging was used to monitor intracellular calcium dynamics. We designed a dedicated cortical flow chamber to remove superficial blood and dye resulting from the injection procedure, which reduced spurious artifacts. The near infrared light used for IOSI and LSCI was delivered via a light pipe integrated with the flow chamber to minimize the effect of fluid surface movement on illumination stability. Calcium-sensitive dye was injected via a glass electrode used for recording the local field potential. Our system allowed us to observe and correlate increases in intracellular calcium, blood flow and blood volume during seizure-like events and provide a quantitative analysis of neurovascular coupling changes associated with seizure rescue via injection of an anti-convulsive agent.

  17. Smart storage technologies applied to fresh foods: A review.

    Science.gov (United States)

    Wang, Jingyu; Zhang, Min; Gao, Zhongxue; Adhikari, Benu

    2017-06-30

    Fresh foods are perishable, seasonal and regional in nature and their storage, transportation, and preservation of freshness are quite challenging. Smart storage technologies can online detection and monitor the changes of quality parameters and storage environment of fresh foods during storage, so that operators can make timely adjustments to reduce the loss. This article reviews the smart storage technologies from two aspects: online detection technologies and smartly monitoring technologies for fresh foods. Online detection technologies include electronic nose, nuclear magnetic resonance (NMR), near infrared spectroscopy (NIRS), hyperspectral imaging and computer vision. Smartly monitoring technologies mainly include some intelligent indicators for monitoring the change of storage environment. Smart storage technologies applied to fresh foods need to be highly efficient and nondestructive and need to be competitively priced. In this work, we have critically reviewed the principles, applications, and development trends of smart storage technologies.

  18. Viable Bacteria Associated with Red Blood Cells and Plasma in Freshly Drawn Blood Donations

    DEFF Research Database (Denmark)

    Damgaard, Christian; Magnussen, Karin; Enevold, Christian

    2015-01-01

    ) or blue lactose plates. For identification colony PCR was performed using primers targeting 16S rDNA. SETTING: Blood donors attending Capital Region Blood Bank, Copenhagen University Hospital, Rigshospitalet, Hvidovre, Denmark, October 29th to December 10th 2013. PARTICIPANTS: 60 donors (≥50 years old....... CONCLUSIONS: Viable bacteria are present in blood from donors self-reported as medically healthy, indicating that conventional test systems employed by blood banks insufficiently detect bacteria in plasma. Further investigation is needed to determine whether routine testing for anaerobic bacteria and testing......OBJECTIVES: Infection remains a leading cause of post-transfusion mortality and morbidity. Bacterial contamination is, however, detected in less than 0.1% of blood units tested. The aim of the study was to identify viable bacteria in standard blood-pack units, with particular focus on bacteria from...

  19. Laser Doppler Blood Flow Imaging Using a CMOS Imaging Sensor with On-Chip Signal Processing

    Directory of Open Access Journals (Sweden)

    Cally Gill

    2013-09-01

    Full Text Available The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.

  20. Laser doppler blood flow imaging using a CMOS imaging sensor with on-chip signal processing.

    Science.gov (United States)

    He, Diwei; Nguyen, Hoang C; Hayes-Gill, Barrie R; Zhu, Yiqun; Crowe, John A; Gill, Cally; Clough, Geraldine F; Morgan, Stephen P

    2013-09-18

    The first fully integrated 2D CMOS imaging sensor with on-chip signal processing for applications in laser Doppler blood flow (LDBF) imaging has been designed and tested. To obtain a space efficient design over 64 × 64 pixels means that standard processing electronics used off-chip cannot be implemented. Therefore the analog signal processing at each pixel is a tailored design for LDBF signals with balanced optimization for signal-to-noise ratio and silicon area. This custom made sensor offers key advantages over conventional sensors, viz. the analog signal processing at the pixel level carries out signal normalization; the AC amplification in combination with an anti-aliasing filter allows analog-to-digital conversion with a low number of bits; low resource implementation of the digital processor enables on-chip processing and the data bottleneck that exists between the detector and processing electronics has been overcome. The sensor demonstrates good agreement with simulation at each design stage. The measured optical performance of the sensor is demonstrated using modulated light signals and in vivo blood flow experiments. Images showing blood flow changes with arterial occlusion and an inflammatory response to a histamine skin-prick demonstrate that the sensor array is capable of detecting blood flow signals from tissue.

  1. A thresholding based technique to extract retinal blood vessels from fundus images

    Directory of Open Access Journals (Sweden)

    Jyotiprava Dash

    2017-12-01

    Full Text Available Retinal imaging has become the significant tool among all the medical imaging technology, due to its capability to extract many data which is linked to various eye diseases. So, the accurate extraction of blood vessel is necessary that helps the eye care specialists and ophthalmologist to identify the diseases at the early stages. In this paper, we have proposed a computerized technique for extraction of blood vessels from fundus images. The process is conducted in three phases: (i pre-processing where the image is enhanced using contrast limited adaptive histogram equalization and median filter, (ii segmentation using mean-C thresholding to extract retinal blood vessels, (iii post-processing where morphological cleaning operation is used to remove isolated pixels. The performance of the proposed method is tested on and experimental results show that our method achieve an accuracies of 0.955 and 0.954 on Digital retinal images for vessel extraction (DRIVE and Child heart and health study in England (CHASE_DB1 databases respectively.

  2. Microparticles variability in fresh frozen plasma: preparation protocol and storage time effects.

    Science.gov (United States)

    Kriebardis, Anastasios G; Antonelou, Marianna H; Georgatzakou, Hara T; Tzounakas, Vassilis L; Stamoulis, Konstantinos E; Papassideri, Issidora S

    2016-05-01

    Extracellular vesicles or microparticles exhibiting procoagulant and thrombogenic activity may contribute to the haemostatic potential of fresh frozen plasma. Fresh frozen plasma was prepared from platelet-rich plasma at 20 °C (Group-1 donors) or directly from whole blood at 4 °C (Group-2 donors). Each unit was aseptically divided into three parts, stored frozen for specific periods of time, and analysed by flow cytometry for procoagulant activity immediately after thaw or following post-thaw storage for 24 h at 4 °C. Donors' haematologic, biochemical and life-style profiles as well as circulating microparticles were analysed in parallel. Circulating microparticles exhibited a considerable interdonor but not intergroup variation. Fresh frozen plasma units were enriched in microparticles compared to plasma in vivo. Duration of storage significantly affected platelet- and red cell-derived microparticles. Fresh frozen plasma prepared directly from whole blood contained more residual platelets and more platelet-derived microparticles compared to fresh frozen plasma prepared from platelet-rich plasma. Consequently, there was a statistically significant difference in total, platelet- and red cell-derived microparticles between the two preparation protocols over storage time in the freezer. Preservation of the thawed units for 24 h at 4 °C did not significantly alter microparticle accumulation. Microparticle accumulation and anti-oxidant capacity of fresh frozen plasma was positively or negatively correlated, respectively, with the level of circulating microparticles in individual donors. The preparation protocol and the duration of storage in the freezer, independently and in combination, influenced the accumulation of microparticles in fresh frozen plasma units. In contrast, storage of thawed units for 24 h at 4 °C had no significant effect on the concentration of microparticles.

  3. Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.

    Science.gov (United States)

    Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin

    2015-12-01

    Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.

  4. Viable bacteria associated with red blood cells and plasma in freshly drawn blood donations.

    Science.gov (United States)

    Damgaard, Christian; Magnussen, Karin; Enevold, Christian; Nilsson, Martin; Tolker-Nielsen, Tim; Holmstrup, Palle; Nielsen, Claus Henrik

    2015-01-01

    Infection remains a leading cause of post-transfusion mortality and morbidity. Bacterial contamination is, however, detected in less than 0.1% of blood units tested. The aim of the study was to identify viable bacteria in standard blood-pack units, with particular focus on bacteria from the oral cavity, and to determine the distribution of bacteria revealed in plasma and in the red blood cell (RBC)-fraction. Cross-sectional study. Blood were separated into plasma and RBC-suspensions, which were incubated anaerobically or aerobically for 7 days on trypticase soy blood agar (TSA) or blue lactose plates. For identification colony PCR was performed using primers targeting 16S rDNA. Blood donors attending Capital Region Blood Bank, Copenhagen University Hospital, Rigshospitalet, Hvidovre, Denmark, October 29th to December 10th 2013. 60 donors (≥50 years old), self-reported medically healthy. Bacterial growth was observed on plates inoculated with plasma or RBCs from 62% of the blood donations. Growth was evident in 21 (35%) of 60 RBC-fractions and in 32 (53%) of 60 plasma-fractions versus 8 of 60 negative controls (p = 0.005 and p = 2.6x10-6, respectively). Propionibacterium acnes was found in 23% of the donations, and Staphylococcus epidermidis in 38%. The majority of bacteria identified in the present study were either facultative anaerobic (59.5%) or anaerobic (27.8%) species, which are not likely to be detected during current routine screening. Viable bacteria are present in blood from donors self-reported as medically healthy, indicating that conventional test systems employed by blood banks insufficiently detect bacteria in plasma. Further investigation is needed to determine whether routine testing for anaerobic bacteria and testing of RBC-fractions for adherent bacteria should be recommended.

  5. The clinical study of cerebral blood flow imaging in patients with early syphilis

    International Nuclear Information System (INIS)

    Liu Zengli; Shi Xin; Wu Jinchang; Tang Jun; Zhong Jijun

    2003-01-01

    Objective: To study the clinical value of cerebral blood flow imaging for evaluation of patients with early syphilis. Methods: Fifty-three patients with early syphilis underwent cerebral blood flow imaging using 99 Tc m -ethylenecysteinate dimer(ECD). Regional cerebral blood flow (rCBF) changes were analyzed. Results: The acquired images of 53 patients were graded as 5 types. The rCBF was significantly depressed in 48 of 53 patients mainly in the areas dominated by anterior cerebral artery and middle cerebral artery. Conclusion: Treponema pallidum (TP) could start invading central nervous system at the early stage of infection

  6. Estimation of center line and diameter of brain blood vessel using three-dimensional blood vessel matching method with head three-dimensional CTA image

    International Nuclear Information System (INIS)

    Maekawa, Masashi; Shinohara, Toshihiro; Nakayama, Masato; Nakasako, Noboru

    2010-01-01

    To support and automate the brain blood vessel disease diagnosis, a novel method to obtain the center line and the diameter of a blood vessel is proposed with a three-dimensional head computed tomographic angiography (CTA) image. Although the line thinning processing with distance transform or gray information is generally used to obtain the blood vessel center line, this method is not essentially one to obtain the center line and tends to yield extra lines depending on CTA images. In this study, the center line of the blood vessel is obtained by tracing the vessel. The blood vessel is traced by sequentially estimating the center point and direction of the blood vessel. The center point and direction of the blood vessel are estimated by taking the correlation between the blood vessel and a solid model of the blood vessel that is designed by considering noise influence. In addition, the vessel diameter is also estimated by correlating the blood vessel and the blood vessel model of which the diameter is variable. The validity of the proposed method is confirmed by experimentally applied the proposed method to an actual three-dimensional head CTA image. (author)

  7. Fusion of spectra and texture data of hyperspectral imaging for the prediction of the water-holding capacity of fresh chicken breast filets

    Science.gov (United States)

    This study investigated the fusion of spectra and texture data of hyperspectral imaging (HSI, 1000–2500 nm) for predicting the water-holding capacity (WHC) of intact, fresh chicken breast filets. Three physical and chemical indicators drip loss, expressible fluid, and salt-induced water gain were me...

  8. Evaluation of RI images of hepatic blood flow using Tc-99m PMT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hiromichi; Iwasaki, Naoya; Ichikawa, Kesato

    1988-03-01

    To evaluate the clinical significance of RI images of hepatic blood flow using Tc-99m-PMT, analysis of the RI images and estimation of hepatic blood flow were carried out in patients with various liver diseases (37 cases). After intravenous injection of Tc-99m-PMT, hepatic accumulation curve of ROI positioned at whole liver area and time activity curve of ROI positioned at celiac artery were obtained through scintillation camera images with the computer-analysed system. Hepatic blood flow coefficient (K) was calculated from the hepatic accumulation curve. Based on the differential curve calculated from the time activity curve, chronological images of arterial, portal, parenchymal and saturated parenchymal phases were obtained. Results ; 1) K was 0.50 + 0.04, 0.35 + 0.02 and 0.26 + 0.04/min in normal type, CH type and LC type respectively. These coefficients well correlated with clinical severity of hepatic diseases. 2) Perfusional phase images of the liver became poorer in accordance with progression of liver disease, while images of spleen, portal venous system and collateral channels were more clearly obtained in liver cirrhosis. This method was shown to have a potential to understanding of severity of liver disease and hepatic blood flow dynamics.

  9. Bone marrow blood supply in gadolinium-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Saifuddin, A.; Bann, K.; Ridgway, J.P.; Butt, W.P.

    1994-01-01

    A retrospective study was performed to determine whether bone blood supply can be assessed on gadolinium-enhanced magnetic resonance imaging. Lumbar spine magnetic resonance imaging (MRI) examinations of 49 patients attending for post-laminectomy examination were reviewed (30 male, 19 female, mean age 46.4 years, age range 23-84 years). Each study included sagittal T1-weighted spin echo sequences before and after gadolinium administration. Regions of interest were drawn within the L3 vertebral body from a parasagittal slice from each sequence. Signal intensity (SI) values were ascertained and the percentage increase in SI was calculated. For each patient, changes in receiver gain for pre- and post-gadolinium images were corrected by an image scaling factor. In all cases, a measurable increase in SI was found (mean 15.3%, range 4.4-55.7) due to bone vascularity. The results give no indication of the quantity or timing of blood supply but provide a basis for further work. (orig.)

  10. Estimation of vessel diameter and blood flow dynamics from laser speckle images

    DEFF Research Database (Denmark)

    Postnov, Dmitry D.; Tuchin, Valery V.; Sosnovtseva, Olga

    2016-01-01

    Laser speckle imaging is a rapidly developing method to study changes of blood velocity in the vascular networks. However, to assess blood flow and vascular responses it is crucial to measure vessel diameter in addition to blood velocity dynamics. We suggest an algorithm that allows for dynamical...

  11. Optimum allocation of imaging time and minimum detectable activity in dual isotope blood pool subtraction indium-111 platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Horowitz, S.F.; Goldsmith, S.J.; Fuster, V.

    1984-01-01

    Indium-111 labeled platelet imaging is a tool for detection of thrombus formation in vascular spaces. Dual isotope blood pool subtraction may help differentiate focal platelet accumulation from blood pool activity. This study used a computer model to calculate the minimum excess-to-blood pool platelet ratio (EX/BP) and the optimum dual isotope imaging times under varied conditions of lesion size. The model simulated usual human imaging doses of 500 μCi of In-111 platelets and 5mCi of Tc-99m labeled RBCs giving a reference cardiac blood pool region (100cc) of 10000 cpm for Tc-99m and 500 cpm for In-111. The total imaging time was fixed at 20 minutes, while the two isotope imaging times (TIn/TTc) were varied, as were the simulated lesion size (cc) and EX/BP. The relative error of the excess counts was calculated using propagation of error theory. At the critical level of detection, where the excess lesion counts equal 3 times the standard deviation, the optimum TIn/TTc and minimum Ex/BP were determined for each lesion size. For the smallest lesion size (0.1cc), the minimum detectable EX/BP ratio was 1.6, with the best TIn/TTC ratio of 18/2 minutes, and for large lesions, an EX/BP of 0.1, with a TIn/TTc of 16/4. This model provides an estimate of the sensitivity and optimizes imaging times in dual isotope subtraction platelet imaging. The model is adaptable to varying isotope doses, total imaging times and lesion size. This information will be helpful in future in- vivo imaging studies of intravascular thrombi in humans

  12. Multimodal imaging of vascular network and blood microcirculation by optical diagnostic techniques

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Meglinski, I V

    2011-01-01

    We present a multimodal optical diagnostic approach for simultaneous non-invasive in vivo imaging of blood and lymphatic microvessels, utilising a combined use of fluorescence intravital microscopy and a method of dynamic light scattering. This approach makes it possible to renounce the use of fluorescent markers for visualisation of blood vessels and, therefore, significantly (tenfold) reduce the toxicity of the technique and minimise side effects caused by the use of contrast fluorescent markers. We demonstrate that along with the ability to obtain images of lymph and blood microvessels with a high spatial resolution, current multimodal approach allows one to observe in real time permeability of blood vessels. This technique appears to be promising in physiology studies of blood vessels, and especially in the study of peripheral cardiovascular system in vivo. (optical technologies in biophysics and medicine)

  13. Frozen cord blood hematopoietic stem cells differentiate into higher numbers of functional natural killer cells in vitro than mobilized hematopoietic stem cells or freshly isolated cord blood hematopoietic stem cells.

    Directory of Open Access Journals (Sweden)

    Martha Luevano

    Full Text Available Adoptive natural killer (NK cell therapy relies on the acquisition of large numbers of NK cells that are cytotoxic but not exhausted. NK cell differentiation from hematopoietic stem cells (HSC has become an alluring option for NK cell therapy, with umbilical cord blood (UCB and mobilized peripheral blood (PBCD34(+ being the most accessible HSC sources as collection procedures are less invasive. In this study we compared the capacity of frozen or freshly isolated UCB hematopoietic stem cells (CBCD34(+ and frozen PBCD34(+ to generate NK cells in vitro. By modifying a previously published protocol, we showed that frozen CBCD34(+ cultures generated higher NK cell numbers without loss of function compared to fresh CBCD34(+ cultures. NK cells generated from CBCD34(+ and PBCD34(+ expressed low levels of killer-cell immunoglobulin-like receptors but high levels of activating receptors and of the myeloid marker CD33. However, blocking studies showed that CD33 expression did not impact on the functions of the generated cells. CBCD34(+-NK cells exhibited increased capacity to secrete IFN-γ and kill K562 in vitro and in vivo as compared to PBCD34(+-NK cells. Moreover, K562 killing by the generated NK cells could be further enhanced by IL-12 stimulation. Our data indicate that the use of frozen CBCD34(+ for the production of NK cells in vitro results in higher cell numbers than PBCD34(+, without jeopardizing their functionality, rendering them suitable for NK cell immunotherapy. The results presented here provide an optimal strategy to generate NK cells in vitro for immunotherapy that exhibit enhanced effector function when compared to alternate sources of HSC.

  14. Tomographic images of cerebral blood flow using a slant hole collimator

    International Nuclear Information System (INIS)

    Wraight, E.P.; Barber, R.W.; Crossland, P.; Maltby, P.

    1983-01-01

    The feasibility of using a rotating slant hole (RSH) collimator on simple tomographic equipment such as a standard gamma camera interfaced to a general purpose Nuclear Medicine computer is reported for producing images of cerebral blood flow following the administration of 123 I-iodoamphetamine to patients. Initial studies produced satisfactory images, thus opening the possibility of tomographic cerebral blood flow imaging to centres not possessing sophisticated tomographic equipment. Planar resolution is superior to that reported for a 25 0 RSH collimator. Axial resolution is not as good at small source distances but is comparable at distances beyond 10 cm. Sensitivity is comparable to other RSH collimators and is similar to Technicare's parallel hole general all purpose collimator. (UK)

  15. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    Energy Technology Data Exchange (ETDEWEB)

    Kamran, Mudassar; Byrne, James V. [University of Oxford, Nuffield Department of Surgical Sciences, Oxford (United Kingdom)

    2015-09-15

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  16. C-arm flat detector computed tomography parenchymal blood volume imaging: the nature of parenchymal blood volume parameter and the feasibility of parenchymal blood volume imaging in aneurysmal subarachnoid haemorrhage patients

    International Nuclear Information System (INIS)

    Kamran, Mudassar; Byrne, James V.

    2015-01-01

    C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31 %) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91 % sensitive and 100 % specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (∼60 % blood flow and ∼40 % blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (∼60 %) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia. (orig.)

  17. Velocity estimation using synthetic aperture imaging [blood flow

    DEFF Research Database (Denmark)

    Nikolov, Svetoslav; Jensen, Jørgen Arendt

    2001-01-01

    Presented an approach for synthetic aperture blood flow ultrasound imaging. Estimates with a low bias and standard deviation can be obtained with as few as eight emissions. The performance of the new estimator is verified using both simulations and measurements. The results demonstrate that a fully...

  18. Computer Aided Solution for Automatic Segmenting and Measurements of Blood Leucocytes Using Static Microscope Images.

    Science.gov (United States)

    Abdulhay, Enas; Mohammed, Mazin Abed; Ibrahim, Dheyaa Ahmed; Arunkumar, N; Venkatraman, V

    2018-02-17

    Blood leucocytes segmentation in medical images is viewed as difficult process due to the variability of blood cells concerning their shape and size and the difficulty towards determining location of Blood Leucocytes. Physical analysis of blood tests to recognize leukocytes is tedious, time-consuming and liable to error because of the various morphological components of the cells. Segmentation of medical imagery has been considered as a difficult task because of complexity of images, and also due to the non-availability of leucocytes models which entirely captures the probable shapes in each structures and also incorporate cell overlapping, the expansive variety of the blood cells concerning their shape and size, various elements influencing the outer appearance of the blood leucocytes, and low Static Microscope Image disparity from extra issues outcoming about because of noise. We suggest a strategy towards segmentation of blood leucocytes using static microscope images which is a resultant of three prevailing systems of computer vision fiction: enhancing the image, Support vector machine for segmenting the image, and filtering out non ROI (region of interest) on the basis of Local binary patterns and texture features. Every one of these strategies are modified for blood leucocytes division issue, in this manner the subsequent techniques are very vigorous when compared with its individual segments. Eventually, we assess framework based by compare the outcome and manual division. The findings outcome from this study have shown a new approach that automatically segments the blood leucocytes and identify it from a static microscope images. Initially, the method uses a trainable segmentation procedure and trained support vector machine classifier to accurately identify the position of the ROI. After that, filtering out non ROI have proposed based on histogram analysis to avoid the non ROI and chose the right object. Finally, identify the blood leucocytes type using

  19. Initial data release of regular blood drip stain created by varying fall height, angle of impact and source dimension

    Directory of Open Access Journals (Sweden)

    Nabanita Basu

    2016-09-01

    Full Text Available The dataset developed consists of 108 blood drip stains developed with fresh porcine blood, blood admixed with different dosage of Warfarin and Heparin, respectively. For each particular blood type (i.e. fresh blood, blood admixed with Warfarin at different dosage and blood admixed with Heparin at varied dosage stain patterns were created by passive dripping of blood from a 2.5 cm3 subcutaneous syringe with needle filled to capacity, at 30°, 60° and 90° angle of impact with corresponding fall height of 20, 40 and 60 cm respectively. In the other dataset of 162 datapoints, 81 regular drip stains were formed from blood that had dripped passively from a subcutaneous syringe without needle at the aforementioned angle of impact and fall height, while the other stains were formed as a result of dripping of blood from a subcutaneous syringe with needle. In order to compare stains formed, all stains were recorded on the same representative, non-porous, smooth target surface under similar physical conditions. The interpretations relevant to the dataset are available in the article titled ‘2D Source Area prediction based on physical characteristics of a regular, passive blood drip stain’ (Basu and Bandyopadhyay, 2016 [7]. An image pre-processing algorithm for extracting ROI has also been incorporated in this article. Keywords: Drip stain, Bloodstain Pattern Analysis, Source Dimension prediction

  20. In-vivo imaging of blood flow dynamics using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2000-04-01

    Noninvasive quantitation of blood flow in the retinal micro circulation may elucidate the progression and treatment of ocular disorders including diabetic retinopathy, age-related degeneration, and glaucoma. Color Doppler optical coherence tomography was recently introduced as a technique allowing simultaneous micron-scale resolution cross-sectional imaging of tissue micro structure and blood flow in the human retina. Here, time-resolved imaging of dynamics of blood flow profiles was performed to measure cardiac pulsatility within retinal vessels. Retinal pulsatility has been shown to decrease throughout the progression of diabetic retinopathy.

  1. Magnetic resonance imaging of large and giant intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kenichi; Saito, Akira; Nakasu, Yoko; Matsuda, Masayuki; Handa, Jyoji [Shiga University of Medical Science, Shiga (Japan); Todo, Giro

    1990-06-01

    Twelve large or giant intracranial aneurysms were studied with magnetic resonance (MR) imaging, and the findings were compared with those from computed tomographic (CT) scanning. Characteristic MR features of such aneurysms are: round, extra-axial mass with hypointensity rim; signal void, paradoxical enhancement, or even-echo rephasing due to blood flow; and laminated, eccentric thrombus with increased signal intensity when fresh, perianeurysmal hemorrhage occurs in the acute or subacute stage after aneurysmal rupture. MR imaging, however, often fails to identify or characterize the area of calcification. For the diagnosis of large or giant intracranial aneurysms, MR imaging is apparently superior to CT scanning in differentiating aneurysms from tumors, delineating the blood flow and intraluminal thrombus, and detecting the exact size of the aneurysm. It may also provide useful information concerning the growth mechanisms of aneurysms with or without thrombus formation. (author).

  2. Frontiers in optical imaging of cerebral blood flow and metabolism.

    Science.gov (United States)

    Devor, Anna; Sakadžić, Sava; Srinivasan, Vivek J; Yaseen, Mohammad A; Nizar, Krystal; Saisan, Payam A; Tian, Peifang; Dale, Anders M; Vinogradov, Sergei A; Franceschini, Maria Angela; Boas, David A

    2012-07-01

    In vivo optical imaging of cerebral blood flow (CBF) and metabolism did not exist 50 years ago. While point optical fluorescence and absorption measurements of cellular metabolism and hemoglobin concentrations had already been introduced by then, point blood flow measurements appeared only 40 years ago. The advent of digital cameras has significantly advanced two-dimensional optical imaging of neuronal, metabolic, vascular, and hemodynamic signals. More recently, advanced laser sources have enabled a variety of novel three-dimensional high-spatial-resolution imaging approaches. Combined, as we discuss here, these methods are permitting a multifaceted investigation of the local regulation of CBF and metabolism with unprecedented spatial and temporal resolution. Through multimodal combination of these optical techniques with genetic methods of encoding optical reporter and actuator proteins, the future is bright for solving the mysteries of neurometabolic and neurovascular coupling and translating them to clinical utility.

  3. Direct Injection of Blood Products Versus Gelatin Sponge as a Technique for Local Hemostasis

    Energy Technology Data Exchange (ETDEWEB)

    Haaga, John [University Hospitals Case Medical Center, Department of Radiology (United States); Rahim, Shiraz, E-mail: Shiraz.rahim@uhhospitals.org

    2017-02-15

    PurposeTo provide a method of reducing risk of minimally invasive procedures on patients with abnormal hemostasis and evaluate efficacy of direct fresh frozen plasma injection through a procedure needle tract compared to Gelfoam (gelatin sponge) administration.Materials and MethodsEighty patients with elevated international standardized ratio (INR) undergoing minimally invasive procedures using imaging guidance were selected retrospectively. Forty patients had received Gelfoam as a means of tract embolization during the procedure. The other 40 received local fresh frozen plasma (FFP) through the needle tract. The number of complications and clinically significant bleeding events were recorded. A threshold of 30 cc of blood loss after a procedure was used to identify excess bleeding.ResultsNo patients experienced clinically significant bleeding after administration of FFP. Five patients experienced postoperative drops in hemoglobin or hematomas after administration of Gelfoam.ConclusionLocal injection of blood products can reduce postprocedure bleeding in patients undergoing minimally invasive procedures and provides a safe alternative to the use of synthetic fibrin plugs.

  4. Feasibility evaluation of 3D photoacoustic imaging of blood vessel structure using multiple wavelengths with a handheld probe

    Science.gov (United States)

    Uchimoto, Yo; Namita, Takeshi; Kondo, Kengo; Yamakawa, Makoto; Shiina, Tsuyoshi

    2018-02-01

    Photoacoustic imaging is anticipated for use in portraying blood vessel structures (e.g. neovascularization in inflamed regions). To reduce invasiveness and enhance ease handling, we developed a handheld photoacoustic imaging system using multiple wavelengths. The usefulness of the proposed system was investigated in phantom experiments and in vivo measurements. A silicon tube was embedded into chicken breast meat to simulate the blood vessel. The tube was filled with ovine blood. Then laser light was guided to the phantom surface by an optical fiber bundle close to the linear ultrasound probe. Photoacoustic images were obtained at 750-950 nm wavelengths. Strong photoacoustic signals from the boundary between blood and silicon tube are observed in these images. The shape of photoacoustic spectrum at the boundary resembles that of the HbO2 absorption spectrum at 750-920 nm. In photoacoustic images, similarity between photoacoustic spectrum and HbO2 absorption spectrum was evaluated by calculating the normalized correlation coefficient. Results show high correlation in regions of strong photoacoustic signals in photoacoustic images. These analyses demonstrate the feasibility of portraying blood vessel structures under practical conditions. To evaluate the feasibility of three-dimensional vascular imaging, in vivo experiments were conducted using three wavelengths. A right hand and ultrasound probe were set in degassed water. By scanning a probe, cross-sectional ultrasound and photoacoustic images were obtained at each location. Then, all ultrasound or photoacoustic images were piled up respectively. Then three-dimensional images were constructed. Resultant images portrayed blood vessel-like structures three-dimensionally. Furthermore, to distinguish blood vessels from other tissues (e.g. skin), distinguishing images of them were constructed by comparing photoacoustic signal intensity among three wavelengths. The resultant image portrayed blood vessels as

  5. Fresh whole blood transfusions in coalition military, foreign national, and enemy combatant patients during Operation Iraqi Freedom at a U.S. combat support hospital.

    Science.gov (United States)

    Spinella, Philip C; Perkins, Jeremy G; Grathwohl, Kurt W; Repine, Thomas; Beekley, Alec C; Sebesta, James; Jenkins, Donald; Azarow, Kenneth; Holcomb, John B

    2008-01-01

    United States military doctrine permits the use of fresh whole blood (FWB), donated by U.S. military personnel on site, for casualties with life-threatening injuries at combat support hospitals. U.S. Military Medical Department policy dictates that all patients treated at military facilities during combat (coalition military personnel, foreign nationals, and enemy combatants) are to be treated equally. The objectives of this study were to describe admission vital signs and laboratory values and injury location for patients transfused with FWB, and to determine if FWB was employed equally among all patient personnel categories at a combat support hospital. This retrospective cohort study evaluated admission vital signs and laboratory values, injury location, and personnel category for all patients receiving FWB at a U.S. Army combat support hospital in Baghdad, Iraq, between January and December 2004. Eighty-seven patients received 545 units of FWB. Upon admission, the average (+/-S.D.) heart rate was 144 bpm (+/-25); systolic blood pressure, 106 mmHg (+/-33); base deficit, 9 (+/-6.5); hemoglobin, 9.0 g/dl (+/-2.6); platelet concentration, 81.9 x 10(3)/mm(3) (+/-81); international normalized ratio (INR), 2.0 (+/-1.1); and temperature 95.7 degrees F (+/-2.6). The percentages of intensive care patients who received FWB by personnel category were as follows: coalition soldiers, 51/592 (8.6%); foreign nationals, 25/347 (7.2%); and enemy combatants, 11/128 (8.5% (p = 0.38). The amount of FWB transfused by personnel category was as follows: coalition soldier, 4 units (1-35); foreign national, 4 units (1-36); and enemy combatant, 4 units (1-11) (p = 0.9). Fresh whole blood was used for anemic, acidemic, hypothermic, coagulopathic patients with life-threatening traumatic injuries in hemorrhagic shock, and it was transfused in equal percentages and amounts for coalition soldiers, foreign nationals, and enemy combatants.

  6. Optimization of ciguatoxin extraction method from blood for Pacific ciguatoxin (P-CTX-1).

    Science.gov (United States)

    Bottein Dechraoui, Marie-Yasmine; Wang, Zhihong; Ramsdell, John S

    2007-01-01

    Ciguatera diagnosis relies on clinical observations associated with a recent consumption of fish. Although needed, direct confirmation of exposure in subjects showing ciguatera disease symptoms is currently unavailable. We previously reported that ciguatoxins were measurable in the blood of mice exposed to extracts of Pacific ciguatoxins isolated from Gambierdiscus polynesiensis, and of Indian Ocean or Caribbean Sea ciguatoxins, isolated from fish. Although highly efficient for extracting spiked purified Caribbean-CTX-1, the methanolic extraction method previously described is found here to yield only 6% recovery of spiked Pacific-CTX-1 (P-CTX-1). We report in this short communication a substantially modified method for ciguatoxin extraction from both dried and fresh blood. With this method, toxin measurement is directly accomplished in acetonitrile deproteinated whole fresh blood or phosphate buffer solution (PBS) eluted dried blood using the N2A cell-based assay. Spike studies using increasing concentrations of purified ciguatoxins reveal linear (r2 above 0.87 for all toxins) and overall efficient toxin recoveries (62%, 96%, and 96% from fresh blood and 75%, 90%, and 74% from dried blood, for C-CTX-1, P-CTX-3C, and P-CTX-1, respectively). Comparative blood matrix analysis for P-CTX-1 recovery shows increased recovery of ciguatoxin activity from whole fresh blood than from dried blood, greater by 20% in P-CTX-1 spiked mice blood and by over 85% in P-CTX-1 exposed mouse blood. In conclusion, both Caribbean and Pacific ciguatoxins can be readily extracted from blood using this modified method; however, in the case of P-CTX-1 we find that fresh blood is optimal.

  7. Imaging of blood plasma coagulation at supported lipid membranes.

    Science.gov (United States)

    Faxälv, Lars; Hume, Jasmin; Kasemo, Bengt; Svedhem, Sofia

    2011-12-15

    The blood coagulation system relies on lipid membrane constituents to act as regulators of the coagulation process upon vascular trauma, and in particular the 2D configuration of the lipid membranes is known to efficiently catalyze enzymatic activity of blood coagulation factors. This work demonstrates a new application of a recently developed methodology to study blood coagulation at lipid membrane interfaces with the use of imaging technology. Lipid membranes with varied net charges were formed on silica supports by systematically using different combinations of lipids where neutral phosphocholine (PC) lipids were mixed with phospholipids having either positively charged ethylphosphocholine (EPC), or negatively charged phosphatidylserine (PS) headgroups. Coagulation imaging demonstrated that negatively charged SiO(2) and membrane surfaces exposing PS (obtained from liposomes containing 30% of PS) had coagulation times which were significantly shorter than those for plain PC membranes and EPC exposing membrane surfaces (obtained from liposomes containing 30% of EPC). Coagulation times decreased non-linearly with increasing negative surface charge for lipid membranes. A threshold value for shorter coagulation times was observed below a PS content of ∼6%. We conclude that the lipid membranes on solid support studied with the imaging setup as presented in this study offers a flexible and non-expensive solution for coagulation studies at biological membranes. It will be interesting to extend the present study towards examining coagulation on more complex lipid-based model systems. Copyright © 2011 Elsevier Inc. All rights reserved.

  8. The challenges of analysing blood stains with hyperspectral imaging

    Science.gov (United States)

    Kuula, J.; Puupponen, H.-H.; Rinta, H.; Pölönen, I.

    2014-06-01

    Hyperspectral imaging is a potential noninvasive technology for detecting, separating and identifying various substances. In the forensic and military medicine and other CBRNE related use it could be a potential method for analyzing blood and for scanning other human based fluids. For example, it would be valuable to easily detect whether some traces of blood are from one or more persons or if there are some irrelevant substances or anomalies in the blood. This article represents an experiment of separating four persons' blood stains on a white cotton fabric with a SWIR hyperspectral camera and FT-NIR spectrometer. Each tested sample includes standardized 75 _l of 100 % blood. The results suggest that on the basis of the amount of erythrocytes in the blood, different people's blood might be separable by hyperspectral analysis. And, referring to the indication given by erythrocytes, there might be a possibility to find some other traces in the blood as well. However, these assumptions need to be verified with wider tests, as the number of samples in the study was small. According to the study there also seems to be several biological, chemical and physical factors which affect alone and together on the hyperspectral analyzing results of blood on fabric textures, and these factors need to be considered before making any further conclusions on the analysis of blood on various materials.

  9. Color image segmentation to detect defects on fresh ham

    Science.gov (United States)

    Marty-Mahe, Pascale; Loisel, Philippe; Brossard, Didier

    2003-04-01

    We present in this paper the color segmentation methods that were used to detect appearance defects on 3 dimensional shape of fresh ham. The use of color histograms turned out to be an efficient solution to characterize the healthy skin, but a special care must be taken to choose the color components because of the 3 dimensional shape of ham.

  10. Hybrid image and blood sampling input function for quantification of small animal dynamic PET data

    International Nuclear Information System (INIS)

    Shoghi, Kooresh I.; Welch, Michael J.

    2007-01-01

    We describe and validate a hybrid image and blood sampling (HIBS) method to derive the input function for quantification of microPET mice data. The HIBS algorithm derives the peak of the input function from the image, which is corrected for recovery, while the tail is derived from 5 to 6 optimally placed blood sampling points. A Bezier interpolation algorithm is used to link the rightmost image peak data point to the leftmost blood sampling point. To assess the performance of HIBS, 4 mice underwent 60-min microPET imaging sessions following a 0.40-0.50-mCi bolus administration of 18 FDG. In total, 21 blood samples (blood-sampled plasma time-activity curve, bsPTAC) were obtained throughout the imaging session to compare against the proposed HIBS method. MicroPET images were reconstructed using filtered back projection with a zoom of 2.75 on the heart. Volumetric regions of interest (ROIs) were composed by drawing circular ROIs 3 pixels in diameter on 3-4 transverse planes of the left ventricle. Performance was characterized by kinetic simulations in terms of bias in parameter estimates when bsPTAC and HIBS are used as input functions. The peak of the bsPTAC curve was distorted in comparison to the HIBS-derived curve due to temporal limitations and delay in blood sampling, which affected the rates of bidirectional exchange between plasma and tissue. The results highlight limitations in using bsPTAC. The HIBS method, however, yields consistent results, and thus, is a substitute for bsPTAC

  11. High-speed video capillaroscopy method for imaging and evaluation of moving red blood cells

    Science.gov (United States)

    Gurov, Igor; Volkov, Mikhail; Margaryants, Nikita; Pimenov, Aleksei; Potemkin, Andrey

    2018-05-01

    The video capillaroscopy system with high image recording rate to resolve moving red blood cells with velocity up to 5 mm/s into a capillary is considered. Proposed procedures of the recorded video sequence processing allow evaluating spatial capillary area, capillary diameter and central line with high accuracy and reliability independently on properties of individual capillary. Two-dimensional inter frame procedure is applied to find lateral shift of neighbor images in the blood flow area with moving red blood cells and to measure directly the blood flow velocity along a capillary central line. The developed method opens new opportunities for biomedical diagnostics, particularly, due to long-time continuous monitoring of red blood cells velocity into capillary. Spatio-temporal representation of capillary blood flow is considered. Experimental results of direct measurement of blood flow velocity into separate capillary as well as capillary net are presented and discussed.

  12. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy.

    Science.gov (United States)

    Cowley, M J; Mantle, J A; Rogers, W J; Russell, R O; Rackley, C E; Logic, J R

    1979-06-01

    It has been suggested that diffuse Tc-99m pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60--90 min following the injection of 12--15 mCi of Tc-99m pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to "rule out" infarction 24--72 hr after onset of suggestive symptoms.

  13. In-Situ Characterization of Tissue Blood Flow, Blood Content, and Water State Using New Techniques in Magnetic Resonance Imaging.

    Science.gov (United States)

    Conturo, Thomas Edward

    Tissue blood flow, blood content, and water state have been characterized in-situ with new nuclear magnetic resonance imaging techniques. The sensitivities of standard techniques to the physiologic tissue parameters spin density (N_{rm r}) and relaxation times (T_1 and T_2 ) are mathematically defined. A new driven inversion method is developed so that tissue T_1 and T_2 changes produce cooperative intensity changes, yielding high contrast, high signal to noise, and sensitivity to a wider range of tissue parameters. The actual tissue parameters were imaged by automated collection of multiple-echo data having multiple T _1 dependence. Data are simultaneously fit by three-parameters to a closed-form expression, producing lower inter-parameter correlation and parameter noise than in separate T_1 or T_2 methods or pre-averaged methods. Accurate parameters are obtained at different field strengths. Parametric images of pathology demonstrate high sensitivity to tissue heterogeneity, and water content is determined in many tissues. Erythrocytes were paramagnetically labeled to study blood content and relaxation mechanisms. Liver and spleen relaxation were enhanced following 10% exchange of animal blood volumes. Rapid water exchange between intracellular and extracellular compartments was validated. Erythrocytes occupied 12.5% of renal cortex volume, and blood content was uniform in the liver, spleen and kidney. The magnitude and direction of flow velocity was then imaged. To eliminate directional artifacts, a bipolar gradient technique sensitized to flow in different directions was developed. Phase angle was reconstructed instead of intensity since the former has a 2pi -fold higher dynamic range. Images of flow through curves demonstrated secondary flow with a centrifugally-biased laminar profile and stationary velocity peaks along the curvature. Portal vein flow velocities were diminished or reversed in cirrhosis. Image artifacts have been characterized and removed. The

  14. Feasibility of the optical imaging of thrombus formation in a rotary blood pump by near-infrared light.

    Science.gov (United States)

    Sakota, Daisuke; Murashige, Tomotaka; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu

    2014-09-01

    Blood coagulation is one of the primary concerns when using mechanical circulatory support devices such as blood pumps. Noninvasive detection and imaging of thrombus formation is useful not only for the development of more hemocompatible devices but also for the management of blood coagulation to avoid risk of infarction. The objective of this study is to investigate the use of near-infrared light for imaging of thrombus formation in a rotary blood pump. The optical properties of a thrombus at wavelengths ranging from 600 to 750 nm were analyzed using a hyperspectral imaging (HSI) system. A specially designed hydrodynamically levitated centrifugal blood pump with a visible bottom area was used. In vitro antithrombogenic testing was conducted five times with the pump using bovine whole blood in which the activated blood clotting time was adjusted to 200 s prior to the experiment. Two halogen lights were used for the light sources. The forward scattering through the pump and backward scattering on the pump bottom area were imaged using the HSI system. HSI showed an increase in forward scattering at wavelengths ranging from 670 to 750 nm in the location of thrombus formation. The time at which the thrombus began to form in the impeller rotating at 2780 rpm could be detected. The spectral difference between the whole blood and the thrombus was utilized to image thrombus formation. The results indicate the feasibility of dynamically detecting and imaging thrombus formation in a rotary blood pump. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  15. Health status of birds fed diets containing three differently processed discarded vegetable-bovine blood-rumen content mixtures.

    Science.gov (United States)

    Ekunseitan, D A; Balogun, O O; Sogunle, O M; Yusuf, A O; Ayoola, A A; Egbeyale, L T; Adeyemi, O A; Allison, I B; Iyanda, A I

    2013-04-01

    This study was conducted to determine the effect of feeding three differently processed mixtures on health status of broilers. A total of 1080 day-old Marshal broilers were fed; discarded vegetable-fresh bovine blood-fresh rumen digesta (P1), discarded vegetable-ensiled bovine blood-fresh rumen digesta (P2) and discarded vegetable-fresh bovine blood-ensiled rumen digesta (P3) at three levels of inclusion (0, 3 and 6%). Data on blood parameters was taken and were subjected to 3 x 3 factorial arrangements in a completely randomized design. Birds fed P1 had least values (p rumen digesta (P3) up to 6% level of inclusion.

  16. Evaluation of ocular acupuncture on cerebral infarction with cerebral blood flow perfusion imaging

    International Nuclear Information System (INIS)

    Li Yuge; Gao Qinyi; Wang Shuang; Zhao Yong

    2008-01-01

    To evaluate the immediate effect of ocular acupuncture on patients, an method of SPECT image of cerebral blood flow daily stress test was established. 10 patients diagnosed as cerebral infarction by CT or MRI were tested. They all received 99 Tc m -ECD SPECT imaging at twice before and after ocular acupuncture. By means of image subtraction technique and semi-quantitative method of regional interesting area, the change of regional cerebral blood flow was observed between the two images. Under restful state perfusion of cerebral blood flow in 18 foci was low at the frontal lobe, the cerebellum, the basal ganglia and temporal lobe. After ocular acupuncture, the perfusions were obviously increased in 16 foci among them and the reactivity of the frontal lobe and the cerebellum to ocular acupuncture was higher, the average improvement rate of which was 55.15% and 53.06% respectively, lower in the basal ganglia and temporal lobe, the average improvement rate was 31.79% and 36.67% respectively. 99 Tc m -ECD SPECT cerebral perfusion image has some significant clinic value for evaluating the effect of ocular acupuncture to treating cerebral infarction. (authors)

  17. Detection of decay in fresh-cut lettuce using hyperspectral imaging and chlorophyll fluorescence imaging

    Science.gov (United States)

    Fresh-cut lettuce sold in modified atmosphere packaging (MAP) is a desirable, but highly perishable product. Decay of tissue can start a few days after processing and may be difficult to detect by quick visual observation. A system for early detection of decay and gradual evaluation of its progress ...

  18. Cerebral blood flow imaging with thallium-201 diethyldithiocarbamate SPECT

    NARCIS (Netherlands)

    van Royen, E. A.; de Bruïne, J. F.; Hill, T. C.; Vyth, A.; Limburg, M.; Byse, B. L.; O'Leary, D. H.; de Jong, J. M.; Hijdra, A.; van der Schoot, J. B.

    1987-01-01

    Thallium-201 diethyldithiocarbamate ([201TI]DDC) was studied in humans as an agent for cerebral blood flow imaging. Brain uptake proved to be complete 90 sec after injection with no appreciable washout or redistribution for hours. Intracarotid injection suggested an almost 100% extraction during the

  19. [Study on modeling method of total viable count of fresh pork meat based on hyperspectral imaging system].

    Science.gov (United States)

    Wang, Wei; Peng, Yan-Kun; Zhang, Xiao-Li

    2010-02-01

    Once the total viable count (TVC) of bacteria in fresh pork meat exceeds a certain number, it will become pathogenic bacteria. The present paper is to explore the feasibility of hyperspectral imaging technology combined with relevant modeling method for the prediction of TVC in fresh pork meat. For the certain kind of problem that has remarkable nonlinear characteristic and contains few samples, as well as the problem that has large amount of data used to express the information of spectrum and space dimension, it is crucial to choose a logical modeling method in order to achieve good prediction result. Based on the comparative result of partial least-squares regression (PLSR), artificial neural networks (ANNs) and least square support vector machines (LS-SVM), the authors found that the PLSR method was helpless for nonlinear regression problem, and the ANNs method couldn't get approving prediction result for few samples problem, however the prediction models based on LS-SVM can give attention to the little training error and the favorable generalization ability as soon as possible, and can make them well synchronously. Therefore LS-SVM was adopted as the modeling method to predict the TVC of pork meat. Then the TVC prediction model was constructed using all the 512 wavelength data acquired by the hyperspectral imaging system. The determination coefficient between the TVC obtained with the standard plate count for bacterial colonies method and the LS-SVM prediction result was 0.987 2 and 0.942 6 for the samples of calibration set and prediction set respectively, also the root mean square error of calibration (RMSEC) and the root mean square error of prediction (RMSEP) was 0.207 1 and 0.217 6 individually, and the result was considerably better than that of MLR, PLSR and ANNs method. This research demonstrates that using the hyperspectral imaging system coupled with the LS-SVM modeling method is a valid means for quick and nondestructive determination of TVC of pork

  20. Systematic Study of the Content of Phytochemicals in Fresh and Fresh-Cut Vegetables

    Directory of Open Access Journals (Sweden)

    María Isabel Alarcón-Flores

    2015-05-01

    Full Text Available Vegetables and fruits have beneficial properties for human health, because of the presence of phytochemicals, but their concentration can fluctuate throughout the year. A systematic study of the phytochemical content in tomato, eggplant, carrot, broccoli and grape (fresh and fresh-cut has been performed at different seasons, using liquid chromatography coupled to triple quadrupole mass spectrometry. It was observed that phenolic acids (the predominant group in carrot, eggplant and tomato were found at higher concentrations in fresh carrot than in fresh-cut carrot. However, in the case of eggplant, they were detected at a higher content in fresh-cut than in fresh samples. Regarding tomato, the differences in the content of phenolic acids between fresh and fresh-cut were lower than in other matrices, except in winter sampling, where this family was detected at the highest concentration in fresh tomato. In grape, the flavonols content (predominant group was higher in fresh grape than in fresh-cut during all samplings. The content of glucosinolates was lower in fresh-cut broccoli than in fresh samples in winter and spring sampling, although this trend changes in summer and autumn. In summary, phytochemical concentration did show significant differences during one-year monitoring, and the families of phytochemicals presented different behaviors depending on the matrix studied.

  1. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Cowley, M.J.; Mantle, J.A.; Rogers, W.J.; Russell, R.O. Jr.; Rackley, C.E.; Logic, J.R.

    1979-01-01

    It has been suggested that diffuse 99m Tc pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60 to 90 min following the injection of 12 to 15 mCi of 99m Tc pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to rule out infarction 24 to 72 hr after onset of suggestive symptoms

  2. The relationship between revascularisation and osteogenesis in fresh or demineralised bone grafts

    DEFF Research Database (Denmark)

    Solheim, E; Pinholt, E M; Talsnes, O

    2001-01-01

    Bone formation generally depends on adequate blood flow. Failure of bone grafts has been attributed to delayed revascularisation of the graft. We compared the relationship between revascularisation and osteogenesis, evaluated as entrapment of (141)Ce-labelled microspheres and uptake of (85)Sr......, respectively, in fresh or demineralised syngeneic bone grafts 3 weeks after heterotopic implantation in rats. Whereas a moderately high linear correlation between (85)Sr and (141)Ce radioactivity was found both in the (intact) host iliac bone (r = 0.75, p = 0.0001) and implanted fresh syngeneic grafts (r = 0...

  3. Changes of renal blood flow after ESWL: Assessment by ASL MR imaging, contrast enhanced MR imaging, and renal resistive index

    Energy Technology Data Exchange (ETDEWEB)

    Abd Ellah, Mohamed, E-mail: dr_m_hamdy2006@hotmail.co [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Kremser, Christian, E-mail: christian.kremser@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Pallwein, Leo, E-mail: leo.pallwein-prettner@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Aigner, Friedrich, E-mail: friedrich.Aigner@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Schocke, Michael, E-mail: michael.schocke@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Peschel, Reinhard, E-mail: reinhard.peschel@uki.a [Innsbruck Medical University, Urology Dept., Anich St. 35, 6020 Innsbruck (Austria); Pedross, Florian, E-mail: florian.pedross@i-med.ac.a [Innsbruck Medical University, Medical Statistics Dept., Anich St. 35, 6020 Innsbruck (Austria); Pinggera, Germar-Michael, E-mail: germar.pinggera@uki.a [Innsbruck Medical University, Urology Dept., Anich St. 35, 6020 Innsbruck (Austria); Wolf, Christian, E-mail: christian.wolf@bkh-reutte.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Alsharkawy, Mostafa A.M., E-mail: drmostafamri@yahoo.co [Assiut University, Radiology Dept., Assiut (Egypt); Jaschke, Werner, E-mail: werner.jaschke@i-med.ac.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria); Frauscher, Ferdinand, E-mail: ferdinand.frauscher@uki.a [Innsbruck Medical University, Radiology Dept., Anich St. 35, 6020 Innsbruck (Austria)

    2010-10-15

    The annual incidence of stone formation is increased in the industrialised world. Extracorporeal shockwave lithotripsy is a non-invasive effective treatment of upper urinary tract stones. This study is aimed to evaluate changes of renal blood flow in patients undergoing extracorporeal shock wave lithotripsy (ESWL) by arterial spin labeling (ASL) MR imaging, contrast enhanced dynamic MR imaging, and renal resistive index (RI). Thirteen patients with nephrolithiasis were examined using MR imaging and Doppler ultrasound 12 h before and 12 h after ESWL. ASL sequence was done for both kidneys and followed by contrast enhanced MR imaging. In addition RI Doppler ultrasound measurements were performed. A significant increase in RI (p < 0.001) was found in both treated and untreated kidneys. ASL MR imaging also showed significant changes in both kidneys (p < 0.001). Contrast enhanced dynamic MR imaging did not show significant changes in the kidneys. ESWL causes changes in RI and ASL MR imaging, which seem to reflect changes in renal blood flow.

  4. Studies on so-called redistribution phenomenon of cerebral blood flow imaging

    International Nuclear Information System (INIS)

    Oba, Hiroshi

    1989-01-01

    To elucidate the relationship between so-called redistribution phenomenon and metabolism or viability of the brain tissue, a new quantitative triple-radionuclide autoradiography was developed, whereby making it possible to compare both late images and reditribution of IMP with cerebral metabolism in experimentally induced unilateral ischemic brain tissue of rats. Iodine-123 IMP and I-125 IMP were used as tracers for early and late imaging, and H-3 amino acid mixture or H-3 H-2 deoxyglucose as a tracer for protein synthesis or glucose metabolism imaging. There was no significant relationship between redistribution index and protein synthesis or glucose metabolism. Protein synthesis was remarkably decreased in the affected hemisphere regardless of redistribution index values. Although the redistribution indices showed a gentle peak at approximately 34 μ mol/100 g/ min of glucose metabolism, there was no obvious relationship between either late images or redistribution index images and glucose metabolism images. Redistribution indices showed a maximum value at approximately 40 to 50 ml/100 g/min of cerebral blood flow. Reverse redistribution was observed with 160 ml/100 g/min or more of flow. Thin layer chromatographic findings were similar in the affected and non-affected resions, suggesting redistribution of a lipophilic IMP metabolite of p-iodoamphetamine in the affected region. In vitro autoradiography revealed no significant reduction in binding ability of IMP to the affected ischemic cortex. In a computer simulation study for brain activity curve, brain activity at 150 min was found to be almost constant at more than 25 ml/100 g/min of flow. IMP redistribution was unlikely to reflect directly either brain metabolism or function, and both blood flow partition coefficient and blood flow values were independently responsible for cerebral kinetics of IMP. (N.K.)

  5. Blood oxygenation level dependent (BOLD). Renal imaging. Concepts and applications

    International Nuclear Information System (INIS)

    Nissen, Johanna C.; Haneder, Stefan; Schoenberg, Stefan O.; Michaely, Henrik J.

    2010-01-01

    Many renal diseases as well as several pharmacons cause a change in renal blood flow and/or renal oxygenation. The blood oxygenation level dependent (BOLD) imaging takes advantage of local field inhomogeneities and is based on a T2 * -weighted sequence. BOLD is a non-invasive method allowing an estimation of the renal, particularly the medullary oxygenation, and an indirect measurement of blood flow without administration of contrast agents. Thus, effects of different drugs on the kidney and various renal diseases can be controlled and observed. This work will provide an overview of the studies carried out so far and identify ways how BOLD can be used in clinical studies. (orig.)

  6. Effect of antibrowning agents on fresh-cut potato tubers using frequency filtering of biospeckle images

    International Nuclear Information System (INIS)

    Minz, Preeti D; Ansari, Md Zaheer; Nirala, A K

    2015-01-01

    Our present work aims to study the physiological changes of chemically treated fresh-cut potato tubers and then to correlate such changes with the results of the non destructive and non invasive laser biospeckle technique. The effect of chemically treated (citric acid (CA-0.5% and 1.0%) and citric acid + sodium chloride (CS-0.5% and 1.0%)) fresh-cut potato tubers on physiological activities such as the respiration rate and weight loss at cold storage has been studied for eight consecutive days. In addition, biospeckle recording has been carried out for eight consecutive days for all the chemically treated samples and from captured images, and the numerical results (inertia moment (IM)) with and without frequency filtering have been obtained. A comparatively higher respiration rate and lower weight loss is observed for CS treated samples than that of CA treated samples. The results of the IM obtained with the exclusion of the higher frequency show a similar nature to the respiration rate and also, separations of the respiration curves at two concentrations for both the treated samples were well correlated with the IM curves. The concentration effect for both the treatments on the IM value with the exclusion of lower frequencies has also been presented. Thus the IM method with filtration of particular bands is able to separate the different physiological phenomena with one another and is also able to differentiate the chemical effect on the samples. (paper)

  7. Induced renal artery stenosis in rabbits: magnetic resonance imaging, angiography, and radionuclide determination of blood volume and blood flow

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Tobin, M.; LeVeen, R.; Tomaczewski, J.; Alavi, A.; Staum, M.; Kundel, H.

    1988-01-01

    To investigate the ability of MRI to detect alterations due to renal ischemia, a rabbit renal artery stenosis (RAS) model was developed. Seven rabbits had RAS induced by surgically encircling the artery with a polyethylene band which had a lumen of 1 mm, 1 to 2 weeks prior to imaging. The stenosis was confirmed by angiography, and the rabbits were then imaged in a 1.4 T research MRI unit. T1 was calculated using four inversion recovery sequences with different inversion times. Renal blood flow, using 113 Sn-microspheres, and regional water content by drying were then measured. The average T1 of the inner medulla was shorter for the ischemia (1574 msec) than for the contralateral kidney (1849 msec), while no change ws noted in the cortex. Ischemic kidneys had less distinct outer medullary zones on IR images with TI = 600 msec than did contralateral or control kidneys. Blood flow to both the cortex and medulla were markedly reduced in ischemic kidneys compared with contralateral kidneys (119.5 vs. 391 ml/min/100 gm for cortex and 19.8 vs. 50.8 ml/min/100 gm for medulla). Renal water and blood content were less affected. Our rabbit model of renal artery stenosis with MRI, radionuclide, and angiographic correlation has the potential to increase our understanding of MR imaging of the rabbit kidney

  8. Changes of renal blood flow after ESWL: assessment by ASL MR imaging, contrast enhanced MR imaging, and renal resistive index.

    Science.gov (United States)

    Abd Ellah, Mohamed; Kremser, Christian; Pallwein, Leo; Aigner, Friedrich; Schocke, Michael; Peschel, Reinhard; Pedross, Florian; Pinggera, Germar-Michael; Wolf, Christian; Alsharkawy, Mostafa A M; Jaschke, Werner; Frauscher, Ferdinand

    2010-10-01

    The annual incidence of stone formation is increased in the industrialised world. Extracorporeal shockwave lithotripsy is a non-invasive effective treatment of upper urinary tract stones. This study is aimed to evaluate changes of renal blood flow in patients undergoing extracorporeal shock wave lithotripsy (ESWL) by arterial spin labeling (ASL) MR imaging, contrast enhanced dynamic MR imaging, and renal resistive index (RI). Thirteen patients with nephrolithiasis were examined using MR imaging and Doppler ultrasound 12h before and 12h after ESWL. ASL sequence was done for both kidneys and followed by contrast enhanced MR imaging. In addition RI Doppler ultrasound measurements were performed. A significant increase in RI (pESWL causes changes in RI and ASL MR imaging, which seem to reflect changes in renal blood flow. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  9. [Ratio of erythrocyte and plasma in massive blood transfusion].

    Science.gov (United States)

    Wen, Xian-Hui; Liu, Feng-Xia; Zhang, Jun-Hua; Gui, Rong

    2014-06-01

    This study was purposed to explore the suitable ratio between fresh frozen plasma and erythrocyte by retrospective analysis of coagulation in patients with massive blood transfusion. The clinical data of 151 cases with massive blood transfusion from January 2011 to January 2013 were analyzed retrospectively. According to coagulation, patients were divided into coagulation normal group (138 cases) and coagulation dysfunction group (13 cases). Based on the ratio of 1:1 of fresh frozen plasma and erythrocyte, the patients were divided into high plasma group(2:1), medium plasma group (1:1) and low plasma (blood transfusion. The results showed that prothrombin time (PT), activated partial thromboplastin time (APTT) and thrombin time (TT) were prolonged, fibrinogen (FIB) level decreased significantly (all P blood transfusion 24 h; the high plasma and the medium plasma group of coagulation normal group had no significant changes in coagulation (P > 0.05); prothrombin time, activated partial thromboplastin time, thrombin time and fibrinogen level in the medium plasma and low plasma subgroup of coagulation dysfunction group after massive transfusion was still in abnormal levels (P > 0.05), coagulation function in high plasma subgroup was improved significantly (P blood transfusion, the ratio between fresh frozen plasma and erythrocyte is recommended to be 2:1 in patients of coagulation dysfunction in order to improve the patient's coagulation function and to reduce the incidence of adverse event, the ratio of fresh frozen plasma to erythrocyte is recommended to be 1:1 in patients with normal coagulation so as to reduce the dilutional coagulopathy and hypervolemia of blood.

  10. Isolation of mesenchymal stem cells from equine umbilical cord blood

    DEFF Research Database (Denmark)

    Koch, Thomas Gadegaard; Heerkens, Tammy; Thomsen, Preben Dybdahl

    2007-01-01

    . The hypothesis of this study was that equine MSCs could be isolated from fresh whole equine cord blood. Results: Cord blood was collected from 7 foals immediately after foaling. The mononuclear cell fraction was isolated by Ficoll density centrifugation and cultured in a DMEM low glucose based media at 38.5o......Background: There are no published studies on stem cells from equine cord blood although commercial storage of equine cord blood for future autologous stem cell transplantations is available. Mesenchymal stem cells (MSC) have been isolated from fresh umbilical cord blood of humans collected non......-invasively at the time of birth and from sheep cord blood collected invasively by a surgical intrauterine approach. Mesenchymal stem cells isolation percentage from frozen-thawed human cord blood is low and the future isolation percentage of MSCs from cryopreserved equine cord blood is therefore expectedly low...

  11. Cytological comparison of gill chloride cells and blood serum ion concentrations in kutum (Rutilus frisii kutum spawners from brackish (Caspian Sea and fresh water (Khoshkrood River environments

    Directory of Open Access Journals (Sweden)

    Ghahremanzadeh Zahra

    2014-09-01

    Full Text Available The size and number of chloride cells and serum ion concentrations in kutum, Rutillus frisii kutum Nordman, from brackish (Caspian Sea and fresh water (Khoshkrood River environments were studied to gain a better understanding of osmoregulation in this species. Twenty mature kutum specimens were collected from the Caspian Sea (Anzali coasts, 8.49 ppt salinity and 12.4°C temperature and 20 specimens from Khoshkrood River (0.18 ppt salinity and 18°C temperature. Gill samples were analyzed histologically and concentrations of Na+, Cl- , K+, and Mg2+ ions were determined in the blood serum. Concentrations of Na+, Cl- , K+, and Mg2+ ions and osmotic pressure in mature kutum from brackish water were significantly higher than in specimens from fresh water. The average size and number of chloride cells in the fish from seawater were considerably larger than those from fresh water. The mean size of chloride cells was 6.89 ± 1.16 μm in brackish water samples and 5.1 ± 0.81 μm in river samples. The average number of chloride cells in brackish and river water samples were 16.92 and 6.57, respectively. The density and size of chloride cells increased with increases in salinity

  12. Magnetic resonance imaging and peripheral blood abnormalities in experimental allergic encephalomyelitis

    International Nuclear Information System (INIS)

    Rose, L.M.; Alvord, E.C. Jr.; Richards, T.L.

    1989-01-01

    Experimental allergic encephalomyelitis (EAE) was induced in twelve cynomologous macaques (Macaca fascicularis) by sensitization to autologous myelin basic protein (BP) in complete Freund's adjuvant (CFA). The white blood cell (WBC) count, absolute number of lymphocytes and absolute numbers of CD4 + and CD8 + T-cell subsets were measured weekly. Using magnetic resonance imaging (MRI), the animals were monitored twice weekly for the development of central nervous system (CNS) lesions. Conventional spin-warp imaging was performed using a General Electric CSI-II NMR imager/spectrometer (2 Tesla magnet). CNS lesions were detected by MRI in all of the animals sensitized to myelin BP. Longitudinal analysis of their peripheral blood leukocytes revealed a progressive leukocytosis and lymphopenia, which always preceded the onset of clinical signs and almost always also preceded the formation of detectable CNS lesions. These results suggest that frequent analysis of T-cell subsets may provide a more accurate means of predicting episodes of disease activity than clinical or MRI evaluation

  13. Red blood cell transfusion is associated with further bleeding and fresh-frozen plasma with mortality in nonvariceal upper gastrointestinal bleeding.

    Science.gov (United States)

    Subramaniam, Kavitha; Spilsbury, Katrina; Ayonrinde, Oyekoya T; Latchmiah, Faye; Mukhtar, Syed A; Semmens, James B; Leahy, Michael F; Olynyk, John K

    2016-04-01

    Blood products are commonly transfused for patients with nonvariceal upper gastrointestinal bleeding (NVUGIB). While concerns exist about further bleeding and mortality in subsets of patients receiving red blood cell (RBC) transfusion, the impact of non-RBC blood products has not previously been systematically investigated. The aim of the study was to investigate the associations between blood products transfusion, further bleeding, and mortality after acute NVUGIB. A retrospective cohort study examined further bleeding and 30-day and 1-year mortality in adult patients who underwent gastroscopy for suspected acute NVUGIB between 2008 and 2010 in three tertiary hospitals in Western Australia. Survival analysis was performed. A total of 2228 adults (63% male) with 2360 hospital admissions for NVUGIB met the inclusion criteria. Median age at presentation was 70 years (range, 19-99 years). Thirty-day mortality was 4.9% and 1-year mortality was 13.9%. Transfusion of 4 or more units of RBCs was associated with greater than 10 times the odds of further bleeding in patients with a hemoglobin level of more than 90 g/L (odds ratio, 11.9; 95% confidence interval [CI], 3.1-45.7; p ≤ 0.001), but was not associated with mortality. Administration of 5 or more units of fresh-frozen plasma (FFP) was associated with increased 30-day (hazard ratio, 2.8; 95% CI, 1.3-5.9; p = 0.008) and 1-year (hazard ratio, 2.6; 95% CI, 1.3-5.0; p = 0.005) mortality after adjusting for coagulopathy, comorbidity, Rockall score, and other covariates. In this large, multicenter study of NVUGIB, RBC transfusion was associated with further bleeding but not mortality, while FFP transfusion was associated with increased mortality in a subset of patients. © 2015 AABB.

  14. Measurement of portal blood flow in healthy individuals: a comparison between magnetic resonance imaging and Doppler ultrasound

    International Nuclear Information System (INIS)

    Costa, Juliana Dantas da; Sebastiane, Patricia Moreno; Leao, Alberto Ribeiro de Souza; Santos, Jose Eduardo Mourao; Moulin, Danilo Sales; D'Ippolito, Giuseppe

    2008-01-01

    Objective: To evaluate the inter-observer agreement between Doppler ultrasonography and magnetic resonance imaging in the quantification of portal blood flow in healthy individuals, as well as evaluating the reproducibility of both methods. Materials and methods: A prospective, transverse, observational and self-paired study was developed evaluating 20 healthy volunteers whose portal blood flow was measured by means of Doppler ultrasonography and magnetic resonance imaging performed by two independent observers. Interobserver and inter method agreements were calculated using the intra class and Pearson's correlation coefficients. Results: The agreement between Doppler ultrasonography and magnetic resonance imaging was low (intra class coefficient: 1.9%-18.2%; Pearson's coefficient: 0.1%-13.7%; p=0.565). Mean values for the portal blood flow measured by Doppler ultrasonography and magnetic resonance imaging were respectively 0.768 l/min and 0.742 l/min. Interobserver agreement for quantification of the portal blood flow by Doppler ultrasonography and magnetic resonance imaging was respectively reasonable (intra class coefficient: 43.3%; Pearson's coefficient: 43.0%) and excellent (intra class coefficient: 91.4%; Pearson's coefficient: 93.4%). Conclusion: In the present study, magnetic resonance imaging demonstrated to be a reliable method for quantifying the portal blood flow, with a higher interobserver agreement than Doppler ultrasonography. The inter method agreement was low. (author)

  15. Using wavelet denoising and mathematical morphology in the segmentation technique applied to blood cells images.

    Science.gov (United States)

    Boix, Macarena; Cantó, Begoña

    2013-04-01

    Accurate image segmentation is used in medical diagnosis since this technique is a noninvasive pre-processing step for biomedical treatment. In this work we present an efficient segmentation method for medical image analysis. In particular, with this method blood cells can be segmented. For that, we combine the wavelet transform with morphological operations. Moreover, the wavelet thresholding technique is used to eliminate the noise and prepare the image for suitable segmentation. In wavelet denoising we determine the best wavelet that shows a segmentation with the largest area in the cell. We study different wavelet families and we conclude that the wavelet db1 is the best and it can serve for posterior works on blood pathologies. The proposed method generates goods results when it is applied on several images. Finally, the proposed algorithm made in MatLab environment is verified for a selected blood cells.

  16. [Prospects in blood transfusion].

    Science.gov (United States)

    Rouger, P

    2003-04-01

    What will be the evolution of blood transfusion in the next 10 years? What are the scientific and medical arguments to help the decision makers to propose the developments? Many scientific and clinical studies show that blood substitutes are not ready for use in man. So, for a long time, blood collection in man will still be a necessity to prepare cell concentrates (red blood cells and platelets) and fresh frozen plasma. During this period, blood safety will be based on development of testing technics and preparation processes of blood products. Another major point will be a better clinical use of blood derivates. Cellular therapy will be probably only a way of diversification in blood transfusion centers in partnership with hospitals.

  17. Hyperspectral imaging and multivariate analysis in the dried blood spots investigations

    Science.gov (United States)

    Majda, Alicja; Wietecha-Posłuszny, Renata; Mendys, Agata; Wójtowicz, Anna; Łydżba-Kopczyńska, Barbara

    2018-04-01

    The aim of this study was to apply a new methodology using the combination of the hyperspectral imaging and the dry blood spot (DBS) collecting. Application of the hyperspectral imaging is fast and non-destructive. DBS method offers the advantage also on the micro-invasive blood collecting and low volume of required sample. During experimental step, the reflected light was recorded by two hyperspectral systems. The collection of 776 spectral bands in the VIS-NIR range (400-1000 nm) and 256 spectral bands in the SWIR range (970-2500 nm) was applied. Pixel has the size of 8 × 8 and 30 × 30 µm for VIS-NIR and SWIR camera, respectively. The obtained data in the form of hyperspectral cubes were treated with chemometric methods, i.e., minimum noise fraction and principal component analysis. It has been shown that the application of these methods on this type of data, by analyzing the scatter plots, allows a rapid analysis of the homogeneity of DBS, and the selection of representative areas for further analysis. It also gives the possibility of tracking the dynamics of changes occurring in biological traces applied on the surface. For the analyzed 28 blood samples, described method allowed to distinguish those blood stains because of time of apply.

  18. Glossiness and perishable food quality: visual freshness judgment of fish eyes based on luminance distribution.

    Science.gov (United States)

    Murakoshi, Takuma; Masuda, Tomohiro; Utsumi, Ken; Tsubota, Kazuo; Wada, Yuji

    2013-01-01

    Previous studies have reported the effects of statistics of luminance distribution on visual freshness perception using pictures which included the degradation process of food samples. However, these studies did not examine the effect of individual differences between the same kinds of food. Here we elucidate whether luminance distribution would continue to have a significant effect on visual freshness perception even if visual stimuli included individual differences in addition to the degradation process of foods. We took pictures of the degradation of three fishes over 3.29 hours in a controlled environment, then cropped square patches of their eyes from the original images as visual stimuli. Eleven participants performed paired comparison tests judging the visual freshness of the fish eyes at three points of degradation. Perceived freshness scores (PFS) were calculated using the Bradley-Terry Model for each image. The ANOVA revealed that the PFS for each fish decreased as the degradation time increased; however, the differences in the PFS between individual fish was larger for the shorter degradation time, and smaller for the longer degradation time. A multiple linear regression analysis was conducted in order to determine the relative importance of the statistics of luminance distribution of the stimulus images in predicting PFS. The results show that standard deviation and skewness in luminance distribution have a significant influence on PFS. These results show that even if foodstuffs contain individual differences, visual freshness perception and changes in luminance distribution correlate with degradation time.

  19. Feeling Fresh

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Feeling Fresh KidsHealth / For Teens / Feeling Fresh Print en español La higiene femenina As ... the other products that claim to make women feel cleaner and fresher. But do these work? And ...

  20. Cardiac tumours: non invasive detection and assessment by gated cardiac blood pool radionuclide imaging

    International Nuclear Information System (INIS)

    Pitcher, D.; Wainwright, R.; Brennand-Roper, D.; Deverall, P.; Sowton, E.; Maisey, M.

    1980-01-01

    Four patients with cardiac tumours were investigated by gated cardiac blood pool radionuclide imaging and echocardiography. Contrast angiocardiography was performed in three of the cases. Two left atrial tumours were detected by all three techniques. In one of these cases echocardiography alone showed additional mitral valve stenosis, but isotope imaging indicated tumour size more accurately. A large septal mass was detected by all three methods. In this patient echocardiography showed evidence of left ventricular outflow obstruction, confirmed at cardiac catheterisation, but gated isotope imaging provided a more detailed assessment of the abnormal cardiac anatomy. In the fourth case gated isotope imaging detected a large right ventricular tumour which had not been identified by echocardiography. Gated cardiac blood pool isotope imaging is a complementary technique to echocardiography for the non-invasive detection and assessment of cardiac tumours. (author)

  1. A novel method for sample preparation of fresh lung cancer tissue for proteomics analysis by tumor cell enrichment and removal of blood contaminants

    Directory of Open Access Journals (Sweden)

    Orre Lotta

    2010-02-01

    Full Text Available Abstract Background In-depth proteomics analyses of tumors are frequently biased by the presence of blood components and stromal contamination, which leads to large experimental variation and decreases the proteome coverage. We have established a reproducible method to prepare freshly collected lung tumors for proteomics analysis, aiming at tumor cell enrichment and reduction of plasma protein contamination. We obtained enriched tumor-cell suspensions (ETS from six lung cancer cases (two adenocarcinomas, two squamous-cell carcinomas, two large-cell carcinomas and from two normal lung samples. The cell content of resulting ETS was evaluated with immunocytological stainings and compared with the histologic pattern of the original specimens. By means of a quantitative mass spectrometry-based method we evaluated the reproducibility of the sample preparation protocol and we assessed the proteome coverage by comparing lysates from ETS samples with the direct lysate of corresponding fresh-frozen samples. Results Cytological analyses on cytospin specimens showed that the percentage of tumoral cells in the ETS samples ranged from 20% to 70%. In the normal lung samples the percentage of epithelial cells was less then 10%. The reproducibility of the sample preparation protocol was very good, with coefficient of variation at the peptide level and at the protein level of 13% and 7%, respectively. Proteomics analysis led to the identification of a significantly higher number of proteins in the ETS samples than in the FF samples (244 vs 109, respectively. Albumin and hemoglobin were among the top 5 most abundant proteins identified in the FF samples, showing a high contamination with blood and plasma proteins, whereas ubiquitin and the mitochondrial ATP synthase 5A1 where among the top 5 most abundant proteins in the ETS samples. Conclusion The method is feasible and reproducible. We could obtain a fair enrichment of cells but the major benefit of the method

  2. Diagnosis of Popliteal Venous Entrapment Syndrome by Magnetic Resonance Imaging Using Blood-Pool Contrast Agents

    International Nuclear Information System (INIS)

    Beitzke, Dietrich; Wolf, Florian; Juelg, Gregor; Lammer, Johannes; Loewe, Christian

    2011-01-01

    Popliteal vascular entrapment syndrome is caused by aberrations or hypertrophy of the gastrocnemius muscles, which compress the neurovascular structures of the popliteal fossa, leading to symptoms of vascular and degeneration as well as aneurysm formation. Imaging of popliteal vascular entrapment may be performed with ultrasound, magnetic resonance imaging (MRI), computed tomography angiography, and conventional angiography. The use of blood-pool contrast agents in MRI when popliteal vascular entrapment is suspected offers the possibility to perform vascular imaging with first-pass magnetic resonance angiographic, high-resolution, steady-state imaging and allows functional tests all within one examination with a single dose of contrast agent. We present imaging findings in a case of symptomatic popliteal vein entrapment diagnosed by the use of blood pool contrast-enhanced MRI.

  3. Multispectral Imaging Analysis of Circulating Tumor Cells in Negatively Enriched Peripheral Blood Samples.

    Science.gov (United States)

    Miller, Brandon; Lustberg, Maryam; Summers, Thomas A; Chalmers, Jeffrey J

    2017-01-01

    A variety of biomarkers are present on cells in peripheral blood of patients with a variety of disorders, including solid tumor malignancies. While rare, characterization of these cells for specific protein levels with the advanced technology proposed, will lead to future validation studies of blood samples as "liquid biopsies" for the evaluation of disease status and therapeutic response. While circulating tumor cells (CTCs) have been isolated in the blood samples of patients with solid tumors, the exact role of CTCs as clinically useful predictive markers is still debated. Current commercial technology has significant bias in that a positive selection technology is used that preassumes specific cell surface markers (such as EpCAM) are present on CTCs. However, CTCs with low EpCAM expression have been experimentally demonstrated to be more likely to be missed by this method. In contrast, this application uses a previously developed, technology that performs a purely negative enrichment methodology on peripheral blood, yielding highly enriched blood samples that contain CTCs as well as other, undefined cell types. The focus of this contribution is the use of multispectral imaging of epifluorescent, microscopic images of these enriched cells in order to help develop clinically relevant liquid biopsies from peripheral blood samples.

  4. Application of image flow cytometry for the characterization of red blood cell morphology

    Science.gov (United States)

    Pinto, Ruben N.; Sebastian, Joseph A.; Parsons, Michael; Chang, Tim C.; Acker, Jason P.; Kolios, Michael C.

    2017-02-01

    Red blood cells (RBCs) stored in hypothermic environments for the purpose of transfusion have been documented to undergo structural and functional changes over time. One sign of the so-called RBC storage lesion is irreversible damage to the cell membrane. Consequently, RBCs undergo a morphological transformation from regular, deformable biconcave discocytes to rigid spheroechinocytes. The spherically shaped RBCs lack the deformability to efficiently enter microvasculature, thereby reducing the capacity of RBCs to oxygenate tissue. Blood banks currently rely on microscope techniques that include fixing, staining and cell counting in order to morphologically characterize RBC samples; these methods are labor intensive and highly subjective. This study presents a novel, high-throughput RBC morphology characterization technique using image flow cytometry (IFC). An image segmentation template was developed to process 100,000 images acquired from the IFC system and output the relative spheroechinocyte percentage. The technique was applied on samples extracted from two blood bags to monitor the morphological changes of the RBCs during in vitro hypothermic storage. The study found that, for a given sample of RBCs, the IFC method was twice as fast in data acquisition, and analyzed 250-350 times more RBCs than the conventional method. Over the lifespan of the blood bags, the mean spheroechinocyte population increased by 37%. Future work will focus on expanding the template to segregate RBC images into more subpopulations for the validation of the IFC method against conventional techniques; the expanded template will aid in establishing quantitative links between spheroechinocyte increase and other RBC storage lesion characteristics.

  5. Automatic analysis of microscopic images of red blood cell aggregates

    Science.gov (United States)

    Menichini, Pablo A.; Larese, Mónica G.; Riquelme, Bibiana D.

    2015-06-01

    Red blood cell aggregation is one of the most important factors in blood viscosity at stasis or at very low rates of flow. The basic structure of aggregates is a linear array of cell commonly termed as rouleaux. Enhanced or abnormal aggregation is seen in clinical conditions, such as diabetes and hypertension, producing alterations in the microcirculation, some of which can be analyzed through the characterization of aggregated cells. Frequently, image processing and analysis for the characterization of RBC aggregation were done manually or semi-automatically using interactive tools. We propose a system that processes images of RBC aggregation and automatically obtains the characterization and quantification of the different types of RBC aggregates. Present technique could be interesting to perform the adaptation as a routine used in hemorheological and Clinical Biochemistry Laboratories because this automatic method is rapid, efficient and economical, and at the same time independent of the user performing the analysis (repeatability of the analysis).

  6. Discrimination between Newly Formed and Aged Thrombi Using Empirical Mode Decomposition of Ultrasound B-Scan Image

    Directory of Open Access Journals (Sweden)

    Jui Fang

    2015-01-01

    Full Text Available Ultrasound imaging is a first-line diagnostic method for screening the thrombus. During thrombus aging, the proportion of red blood cells (RBCs in the thrombus decreases and therefore the signal intensity of B-scan can be used to detect the thrombus age. To avoid the effect of system gain on the measurements, this study proposed using the empirical mode decomposition (EMD of ultrasound image as a strategy to classify newly formed and aged thrombi. Porcine blood samples were used for the in vitro induction of fresh and aged thrombi (at hematocrits of 40%. Each thrombus was imaged using an ultrasound scanner at different gains (15, 20, and 30 dB. Then, EMD of ultrasound signals was performed to obtain the first and second intrinsic mode functions (IMFs, which were further used to calculate the IMF-based echogenicity ratio (IER. The results showed that the performance of using signal amplitude of B-scan to reflect the thrombus age depends on gain. However, the IER is less affected by the gain in discriminating between fresh and aged thrombi. In the future, ultrasound B-scan combined with the EMD may be used to identify the thrombus age for the establishment of thrombolytic treatment planning.

  7. High Frame-Rate Blood Vector Velocity Imaging Using Plane Waves: Simulations and Preliminary Experiments

    DEFF Research Database (Denmark)

    Udesen, Jesper; Gran, Fredrik; Hansen, Kristoffer Lindskov

    2008-01-01

    ) The ultrasound is not focused during the transmissions of the ultrasound signals; 2) A 13-bit Barker code is transmitted simultaneously from each transducer element; and 3) The 2-D vector velocity of the blood is estimated using 2-D cross-correlation. A parameter study was performed using the Field II program......, and performance of the method was investigated when a virtual blood vessel was scanned by a linear array transducer. An improved parameter set for the method was identified from the parameter study, and a flow rig measurement was performed using the same improved setup as in the simulations. Finally, the common...... carotid artery of a healthy male was scanned with a scan sequence that satisfies the limits set by the Food and Drug Administration. Vector velocity images were obtained with a frame-rate of 100 Hz where 40 speckle images are used for each vector velocity image. It was found that the blood flow...

  8. Imaging blood-brain barrier dysfunction as a biomarker for epileptogenesis.

    Science.gov (United States)

    Bar-Klein, Guy; Lublinsky, Svetlana; Kamintsky, Lyn; Noyman, Iris; Veksler, Ronel; Dalipaj, Hotjensa; Senatorov, Vladimir V; Swissa, Evyatar; Rosenbach, Dror; Elazary, Netta; Milikovsky, Dan Z; Milk, Nadav; Kassirer, Michael; Rosman, Yossi; Serlin, Yonatan; Eisenkraft, Arik; Chassidim, Yoash; Parmet, Yisrael; Kaufer, Daniela; Friedman, Alon

    2017-06-01

    A biomarker that will enable the identification of patients at high-risk for developing post-injury epilepsy is critically required. Microvascular pathology and related blood-brain barrier dysfunction and neuroinflammation were shown to be associated with epileptogenesis after injury. Here we used prospective, longitudinal magnetic resonance imaging to quantitatively follow blood-brain barrier pathology in rats following status epilepticus, late electrocorticography to identify epileptic animals and post-mortem immunohistochemistry to confirm blood-brain barrier dysfunction and neuroinflammation. Finally, to test the pharmacodynamic relevance of the proposed biomarker, two anti-epileptogenic interventions were used; isoflurane anaesthesia and losartan. Our results show that early blood-brain barrier pathology in the piriform network is a sensitive and specific predictor (area under the curve of 0.96, P brain barrier pathology as a clinically relevant predictive, diagnostic and pharmaco!dynamics biomarker for acquired epilepsy. © The Author (2017). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Analysis of blood flow dynamics in the abdominal aorta based on MR images

    International Nuclear Information System (INIS)

    Shimamura, Koumei; Tsubota, Kenichi; Ryu, Hiroshi; Sugimoto, Koichi; Haneishi, Hideaki

    2010-01-01

    Images of the abdominal aorta including peri-renal artery by PCMRA (phase contrast magnetic resonance angiography) were analyzed to calculate WSS (wall shear stress) and its OSI (oscillatory shear index) in order to visually elucidate the cause of aneurysm formation. PCMRA was conducted for acquisitions of vascular morphology in one cardiac cycle of a healthy male 30s with cardiac gating, and of blood flow rates from 3 directions. Images were median-filtered to reduce noises and regions of interest of rectangular parallelepiped were defined to involve the aorta. WSS, the parameter representing the intensity of friction stress to the vessel wall of blood flow, and OSI, the degree of oscillatory WSS change, were calculated firstly by the reported Snake model for the vessel morphology and then by applying its local information to blood flow rate information from 3 directions. Color-displayed images revealed that both WSS and OS were high at the highest incidental region of aortic aneurysm formation around the peri-renal artery. The finding was in good agreement with the result of computed bio-dynamic simulation that the strong WSS by elevated swirling of blood flow is generated at the region. Thus WSS and OS can be significant factors of aneurismal formation, which should be further confirmed from aspects of increased case number and precision. (T.T.)

  10. Nephron blood flow dynamics measured by laser speckle contrast imaging

    DEFF Research Database (Denmark)

    von Holstein-Rathlou, Niels-Henrik; Sosnovtseva, Olga V; Pavlov, Alexey N

    2011-01-01

    Tubuloglomerular feedback (TGF) has an important role in autoregulation of renal blood flow and glomerular filtration rate (GFR). Because of the characteristics of signal transmission in the feedback loop, the TGF undergoes self-sustained oscillations in single-nephron blood flow, GFR, and tubular...... simultaneously. The interacting nephron fields are likely to be more extensive. We have turned to laser speckle contrast imaging to measure the blood flow dynamics of 50-100 nephrons simultaneously on the renal surface of anesthetized rats. We report the application of this method and describe analytic...... pressure and flow. Nephrons interact by exchanging electrical signals conducted electrotonically through cells of the vascular wall, leading to synchronization of the TGF-mediated oscillations. Experimental studies of these interactions have been limited to observations on two or at most three nephrons...

  11. Dynamic glucose enhanced (DGE) MRI for combined imaging of blood-brain barrier break down and increased blood volume in brain cancer.

    Science.gov (United States)

    Xu, Xiang; Chan, Kannie W Y; Knutsson, Linda; Artemov, Dmitri; Xu, Jiadi; Liu, Guanshu; Kato, Yoshinori; Lal, Bachchu; Laterra, John; McMahon, Michael T; van Zijl, Peter C M

    2015-12-01

    Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. Mice were inoculated orthotopically with human U87-EGFRvIII glioma cells. Time-resolved glucose signal changes were detected using chemical exchange saturation transfer (glucoCEST) MRI. Dynamic glucose enhanced (DGE) MRI was used to measure tissue response to an intravenous bolus of d-glucose. DGE images of mouse brains bearing human glioma showed two times higher and persistent changes in tumor compared with contralateral brain. Area-under-curve (AUC) analysis of DGE delineated blood vessels and tumor and had contrast comparable to the AUC determined using dynamic contrast enhanced (DCE) MRI with GdDTPA, both showing a significantly higher AUC in tumor than in brain (P blood volume and permeability with respect to normal brain. We expect DGE will provide a low-risk and less expensive alternative to DCE MRI for imaging cancer in vulnerable populations, such as children and patients with renal impairment. © 2015 Wiley Periodicals, Inc.

  12. Fibre optic confocal imaging (FOCI) of keratinocytes, blood vessels and nerves in hairless mouse skin in vivo

    Science.gov (United States)

    BUSSAU, L. J.; VO, L. T.; DELANEY, P. M.; PAPWORTH, G. D.; BARKLA, D. H.; KING, R. G.

    1998-01-01

    Fibre optic confocal imaging (FOCI) enabled subsurface fluorescence microscopy of the skin of hairless mice in vivo. Application of acridine orange enabled imaging of the layers of the epidermis. The corneocytes of the stratum corneum, the keratinocytes in the basal layers and redundant hair follicles were visualised at depths greater than 100 μm. Cellular and nuclear membranes of keratinocytes of the skin were visualised by the use of acridine orange and DIOC5(3). Imaging of the skin after injection of FITC-dextran revealed an extensive network of blood vessels with a size range up to 20 μm. Blood cells could be seen moving through dermal vessels and the blood circulation through the dermal vascular bed was video-taped. The fluorescent dye 4-di-2-ASP showed the presence of nerves fibres around the hair follicles and subsurface blood vessels. Comparison was made between images obtained in vivo using FOCI and in vitro scanning electron microscopy and conventional histology. FOCI offers the potential to study dynamic events in vivo, such as blood flow, skin growth, nerve regeneration and many pathological processes, in ways which have not previously been possible. PMID:9643419

  13. Noninvasive, low-noise, fast imaging of blood volume and deoxygenation changes in muscles using light-emitting diode continuous-wave imager

    Science.gov (United States)

    Lin, Yuanqing; Lech, Gwen; Nioka, Shoko; Intes, Xavier; Chance, Britton

    2002-08-01

    This article focuses on optimizing the signal to noise ratio (SNR) of a three-wavelength light-emitting diode (LED) near-infrared continuous-wave (cw) imager and its application to in vivo muscle metabolism measurement. The shot-noise limited SNR is derived and calculated to be 2 x104 for the physiological blood concentrations of muscle. Aiming at shot-noise limited SNR performance and fast imaging, we utilize sample and hold circuits to reduce high-frequency noise. These circuits have also been designed to be parallel integrating, through which SNR of 2 x103 and 2 Hz imaging acquisition rate have been achieved when the probe is placed on a muscle model. The noise corresponds to 2 x10-4 optical density error, which suggests an in vitro resolution of 15. 4 nM blood volume and 46.8 nM deoxygenation changes. A 48 dB digital gain control circuit with 256 steps is employed to enlarge the dynamic range of the imager. We utilize cuff ischemia as a living model demonstration and its results are reported. The instrument is applied during exercise to measure the changes of blood volume and deoxygenation, which provides important information about muscle metabolism. We find that the primary source of noise encountered during exercise experiment is from the random motion of muscle. The results demonstrate that the LED cw imager is ideal for the noninvasive study of muscle metabolism.

  14. Calculation of Blood Dose in Patients Treated With 131I Using MIRD, Imaging, and Blood Sampling Methods.

    Science.gov (United States)

    Piruzan, Elham; Haghighatafshar, Mahdi; Faghihi, Reza; Entezarmahdi, Seyed Mohammad

    2016-03-01

    Radioiodine therapy is known as the most effective treatment of differentiated thyroid carcinoma (DTC) to ablate remnant thyroid tissue after surgery. In patients with DTC treated with radioiodine, internal radiation dosimetry of radioiodine is useful for radiation risk assessment. The aim of this study is to describe a method to estimate the absorbed dose to the blood using medical internal radiation dosimetry methods. In this study, 23 patients with DTC with different administrated activities, 3.7, 4.62, and 5.55 GBq after thyroidectomy, were randomly selected. Blood dosimetry of treated patients was performed with external whole body counting using a dual-head gamma camera imaging device and also with blood sample activity measurements using a dose calibrator. Absorbed dose to the blood was measured at 2, 6, 12, 24, 48, and 96 hours after the administration of radioiodine with the 2 methods. Based on the results of whole body counting and blood sample activity dose rate measurements, 96 hours after administration of 3.7, 4.62, and 5.55 GBq of radioiodine, absorbed doses to patients' blood were 0.65 ± 0.20, 0.67 ± 0.18, 0.79 ± 0.51 Gy, respectively. Increasing radioiodine activity from 3.7 to 5.55 GBq increased blood dose significantly, while there was no significant difference in blood dose between radioiodine dosages of 3.7 and 4.62 GBq. Our results revealed a significant correlation between the blood absorbed dose and blood sample activity and between the blood absorbed dose and whole body counts 24 to 48 hours after the administration of radioiodine.

  15. Application of Thinned-Skull Cranial Window to Mouse Cerebral Blood Flow Imaging Using Optical Microangiography

    Science.gov (United States)

    Wang, Ruikang K.

    2014-01-01

    In vivo imaging of mouse brain vasculature typically requires applying skull window opening techniques: open-skull cranial window or thinned-skull cranial window. We report non-invasive 3D in vivo cerebral blood flow imaging of C57/BL mouse by the use of ultra-high sensitive optical microangiography (UHS-OMAG) and Doppler optical microangiography (DOMAG) techniques to evaluate two cranial window types based on their procedures and ability to visualize surface pial vessel dynamics. Application of the thinned-skull technique is found to be effective in achieving high quality images for pial vessels for short-term imaging, and has advantages over the open-skull technique in available imaging area, surgical efficiency, and cerebral environment preservation. In summary, thinned-skull cranial window serves as a promising tool in studying hemodynamics in pial microvasculature using OMAG or other OCT blood flow imaging modalities. PMID:25426632

  16. Digital image analysis of radial shrinkage of fresh spruce (Picea abies L.) wood.

    Science.gov (United States)

    Hansmann, Christian; Konnerth, Johannes; Rosner, Sabine

    2011-03-21

    Contact-free digital image analysis was performed of the radial shrinkage of fresh, fully saturated small spruce wood beams. An experimental test set-up was developed to ensure constant distance from the charge-coupled device camera to the sample surface as well as constant climate and light conditions during the whole experiment. Dimensional changes were observed immediately after the drying process began. An unexpected distinct effect could be observed which could not be explained by drying surface layers only. After a fast initial radial shrinkage a slowing down of the dimensional changes occurred at high mean moisture contents. A complete interruption of any dimensional changes followed. Finally, a recovery from shrinkage was even observed. It is assumed that strong negative pressure occurred in the fully saturated capillaries owing to dehydration which led to additional dimensional changes. As a consequence, the break of the water column and aeration in these capillaries finally resulted in a recovery period in the shrinkage rate due to the pressure release. After this effect, the dehydration was characterized by a phase of fast and almost linear shrinkage due to drying surface layers. Finally, the shrinkage slowed down to zero when reaching equilibrium moisture content.

  17. Extraction of Nucleolus Candidate Zone in White Blood Cells of Peripheral Blood Smear Images Using Curvelet Transform

    Directory of Open Access Journals (Sweden)

    Ramin Soltanzadeh

    2012-01-01

    Full Text Available The main part of each white blood cell (WBC is its nucleus which contains chromosomes. Although white blood cells (WBCs with giant nuclei are the main symptom of leukemia, they are not sufficient to prove this disease and other symptoms must be investigated. For example another important symptom of leukemia is the existence of nucleolus in nucleus. The nucleus contains chromatin and a structure called the nucleolus. Chromatin is DNA in its active form while nucleolus is composed of protein and RNA, which are usually inactive. In this paper, to diagnose this symptom and in order to discriminate between nucleoli and chromatins, we employ curvelet transform, which is a multiresolution transform for detecting 2D singularities in images. For this reason, at first nuclei are extracted by means of K-means method, then curvelet transform is applied on extracted nuclei and the coefficients are modified, and finally reconstructed image is used to extract the candidate locations of chromatins and nucleoli. This method is applied on 100 microscopic images and succeeds with specificity of 80.2% and sensitivity of 84.3% to detect the nucleolus candidate zone. After nucleolus candidate zone detection, new features that can be used to classify atypical and blast cells such as gradient of saturation channel are extracted.

  18. Fast and robust segmentation of white blood cell images by self-supervised learning.

    Science.gov (United States)

    Zheng, Xin; Wang, Yong; Wang, Guoyou; Liu, Jianguo

    2018-04-01

    A fast and accurate white blood cell (WBC) segmentation remains a challenging task, as different WBCs vary significantly in color and shape due to cell type differences, staining technique variations and the adhesion between the WBC and red blood cells. In this paper, a self-supervised learning approach, consisting of unsupervised initial segmentation and supervised segmentation refinement, is presented. The first module extracts the overall foreground region from the cell image by K-means clustering, and then generates a coarse WBC region by touching-cell splitting based on concavity analysis. The second module further uses the coarse segmentation result of the first module as automatic labels to actively train a support vector machine (SVM) classifier. Then, the trained SVM classifier is further used to classify each pixel of the image and achieve a more accurate segmentation result. To improve its segmentation accuracy, median color features representing the topological structure and a new weak edge enhancement operator (WEEO) handling fuzzy boundary are introduced. To further reduce its time cost, an efficient cluster sampling strategy is also proposed. We tested the proposed approach with two blood cell image datasets obtained under various imaging and staining conditions. The experiment results show that our approach has a superior performance of accuracy and time cost on both datasets. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Evaluation of musculoskeletal sepsis with indium-111 white blood cell imaging

    International Nuclear Information System (INIS)

    Ouzounian, T.J.; Thompson, L.; Grogan, T.J.; Webber, M.M.; Amstutz, H.C.

    1987-01-01

    The detection of musculoskeletal sepsis, especially following joint replacement, continues to be a challenging problem. Often, even with invasive diagnostic evaluation, the diagnosis of infection remains uncertain. This is a report on the first 55 Indium-111 white blood cell (WBC) images performed in 39 patients for the evaluation of musculoskeletal sepsis. There were 40 negative and 15 positive Indium-111 WBC images. These were correlated with operative culture and tissue pathology, aspiration culture, and clinical findings. Thirty-eight images were performed for the evaluation of possible total joint sepsis (8 positive and 30 negative images); 17 for the evaluation of nonarthroplasty-related musculoskeletal sepsis (7 positive and 10 negative images). Overall, there were 13 true-positive, 39 true-negative, two false-positive, and one false-negative images. Indium-111 WBC imaging is a sensitive and specific means of evaluating musculoskeletal sepsis, especially following total joint replacement

  20. Technical Note: Measurement of common carotid artery lumen dynamics using black-blood MR cine imaging.

    Science.gov (United States)

    Dai, Erpeng; Dong, Li; Zhang, Zhe; Li, Lyu; Zhang, Hui; Zhao, Xihai; Wang, Jinnan; Yuan, Chun; Guo, Hua

    2017-03-01

    To demonstrate the feasibility of measuring the common carotid artery (CCA) lumen dynamics using a black-blood cine (BB-cine) imaging method. Motion-sensitized driven-equilibrium (MSDE) prepared spoiled gradient sequence was used for the BB-cine imaging. CCAs of eleven healthy volunteers were studied using this method. Lumen dynamics, including lumen area evolution waveforms and distension values, were measured and evaluated by comparing this method with bright-blood cine (BrB-cine) imaging. Compared with the BrB-cine images, flow artifacts were effectively suppressed in the BB-cine images. BrB-cine images generally show larger lumen areas than BB-cine images. The lumen area waveforms and distension measurements from BB-cine imaging showed smaller variances among different subjects than BrB-cine imaging. The proposed BB-cine imaging technique can suppress the flow artifacts effectively and reduce the partial volume effects from the vessel wall. This might allow more accurate lumen dynamics measurements than traditional BrB-cine imaging, which may further be valuable for investigating biomechanical and functional properties of the cardiovascular system. © 2017 American Association of Physicists in Medicine.

  1. Blood and Blood Components: From Similarities to Differences

    Directory of Open Access Journals (Sweden)

    Olivier Garraud

    2018-04-01

    Full Text Available Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025, many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations of blood transfusion diversity and the consequences for donors, patients, and society.

  2. Blood and Blood Components: From Similarities to Differences

    Science.gov (United States)

    Garraud, Olivier; Tissot, Jean-Daniel

    2018-01-01

    Blood transfusion is made possible because, in most countries and organizations, altruistic individuals voluntarily, anonymously, and generously donate (without compensation) either whole blood or separated components that are then processed and distributed by professionals, prior to being allocated to recipients in need. Being part of modern medicine, blood transfusion uses so-called standard blood components when relative to cellular fractions and fresh plasma. However, as will be discussed in this paper, strictly speaking, such so-called labile blood components are not completely standard. Furthermore, the prevalent system based on voluntary, non-remunerated blood donation is not yet universal and, despite claims by the World Health Organization that 100% of blood collection will be derived from altruistic donations by 2020 (postponed to 2025), many obstacles may hinder this ambition, especially when relative to the collection of the enormous amount of plasma destined for fractionation into plasma derivative or drugs. Finally, country organizations also vary due to the economy, sociology, politics, and epidemiology. This paper then, discusses the particulars (of which ethical considerations) of blood transfusion diversity and the consequences for donors, patients, and society. PMID:29686986

  3. Fingerprint enhancement revisited and the effects of blood enhancement chemicals on subsequent profiler Plus fluorescent short tandem repeat DNA analysis of fresh and aged bloody fingerprints.

    Science.gov (United States)

    Frégeau, C J; Germain, O; Fourney, R M

    2000-03-01

    This study was aimed at determining the effect of seven blood enhancement reagents on the subsequent Profiler Plus fluorescent STR DNA analysis of fresh or aged bloody fingerprints deposited on various porous and nonporous surfaces. Amido Black, Crowle's Double Stain. 1,8-diazafluoren-9-one (DFO), Hungarian Red, leucomalachite green, luminol and ninhydrin were tested on linoleum, glass, metal, wood (pine, painted white), clothing (85% polyester/15% cotton, 65% polyester/35% cotton, and blue denim) and paper (Scott 2-ply and Xerox-grade). Preliminary experiments were designed to determine the optimal blood dilutions to use to ensure a DNA typing result following chemical enhancement. A 1:200 blood dilution deposited on linoleum and enhanced with Crowle's Double Stain generated enough DNA for one to two rounds of Profiler Plus PCR amplification. A comparative study of the DNA yields before and after treatment indicated that the quantity of DNA recovered from bloody fingerprints following enhancement was reduced by a factor of 2 to 12. Such a reduction in the DNA yields could potentially compromise DNA typing analysis in the case of small stains. The blood enhancement chemicals selected were also evaluated for their capability to reveal bloodmarks on the various porous and nonporous surfaces chosen in this study. Luminol. Amido Black and Crowle's Double Stain showed the highest sensitivity of all seven chemicals tested and revealed highly diluted (1:200) bloody fingerprints. Both luminol and Amido Black produced excellent results on both porous and nonporous surfaces, but Crowle's Double Stain failed to produce any results on porous substrates. Hungarian Red, DFO, leucomalachite green and ninhydrin showed lower sensitivities. Enhancement of bloodmarks using any of the chemicals selected, and short-term exposure to these same chemicals (i.e., less than 54 days), had no adverse effects on the PCR amplification of the nine STR systems surveyed (D3S 1358, HumvWA, Hum

  4. Potentials for export of fresh raspberries from Serbia to EU fresh markets

    Directory of Open Access Journals (Sweden)

    Nikolić Ivan

    2012-12-01

    Full Text Available The aim of this paper is to present potentials of the most significant EU national markets for imports of fresh raspberries from Serbia. We carried out analysis of three markets with highest trade deficit of fresh raspberries expressed in quantities: Germany, Netherlands and Austria. The paper further analyses production and foreign trade trends in selected countries. According to results of this analysis, we identified monthly periods with highest potential for exports of fresh raspberries from Serbia to target markets. The paper also analyses wholesale prices of fresh raspberries and EU policy of direct support to raspberry producers.

  5. Unique identification code for medical fundus images using blood vessel pattern for tele-ophthalmology applications.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore; Sharma, Dilip Kumar

    2016-10-01

    Identification of fundus images during transmission and storage in database for tele-ophthalmology applications is an important issue in modern era. The proposed work presents a novel accurate method for generation of unique identification code for identification of fundus images for tele-ophthalmology applications and storage in databases. Unlike existing methods of steganography and watermarking, this method does not tamper the medical image as nothing is embedded in this approach and there is no loss of medical information. Strategic combination of unique blood vessel pattern and patient ID is considered for generation of unique identification code for the digital fundus images. Segmented blood vessel pattern near the optic disc is strategically combined with patient ID for generation of a unique identification code for the image. The proposed method of medical image identification is tested on the publically available DRIVE and MESSIDOR database of fundus image and results are encouraging. Experimental results indicate the uniqueness of identification code and lossless recovery of patient identity from unique identification code for integrity verification of fundus images. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Estimation of lung volume and pulmonary blood volume from radioisotopic images

    International Nuclear Information System (INIS)

    Kanazawa, Minoru

    1989-01-01

    Lung volume and pulmonary blood volume in man were estimated from the radioisotopic image using single photon emission computed tomography (SPECT). Six healthy volunteers were studied in a supine position with normal and altered lung volumes by applying continuous negative body-surface pressure (CNP) and by positive end-expiratory pressure (PEEP). 99m Tc labeled human serum albumin was administered as an aerosol to image the lungs. The CNP caused the diaphragm to be lowered and it increased the mean lung tissue volume obtained by SPECT from 3.09±0.49 l for baseline to 3.67±0.62 l for 10 cmH 2 O (p 2 O (p 2 O), respectively. The PEEP also increased the lung tissue volume to 3.68±0.68 l for 10 cmH 2 O as compared with the baseline (p 2 O PEEP. The lung tissue volume obtained by SPECT showed a positive correlation with functional residual capacity measured by the He dilution method (r=0.91, p 99m Tc-labeled red blood cells. The L/H ratio decreased after either the CNP or PEEP, suggesting a decrease in the blood volume per unit lung volume. However, it was suggested that the total pulmonary blood volume increased slightly either on the CNP (+7.4% for 10 cmH 2 O, p 2 O,p<0.05) when we extrapolated the L/H ratio to the whole lungs by multiplying the lung tissue volume obtained by SPECT. We concluded that SPECT could offer access to the estimation of lung volume and pulmonary blood volume in vivo. (author)

  7. Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues

    Science.gov (United States)

    Tzoumas, Stratis; Nunes, Antonio; Olefir, Ivan; Stangl, Stefan; Symvoulidis, Panagiotis; Glasl, Sarah; Bayer, Christine; Multhoff, Gabriele; Ntziachristos, Vasilis

    2016-06-01

    Light propagating in tissue attains a spectrum that varies with location due to wavelength-dependent fluence attenuation, an effect that causes spectral corruption. Spectral corruption has limited the quantification accuracy of optical and optoacoustic spectroscopic methods, and impeded the goal of imaging blood oxygen saturation (sO2) deep in tissues; a critical goal for the assessment of oxygenation in physiological processes and disease. Here we describe light fluence in the spectral domain and introduce eigenspectra multispectral optoacoustic tomography (eMSOT) to account for wavelength-dependent light attenuation, and estimate blood sO2 within deep tissue. We validate eMSOT in simulations, phantoms and animal measurements and spatially resolve sO2 in muscle and tumours, validating our measurements with histology data. eMSOT shows substantial sO2 accuracy enhancement over previous optoacoustic methods, potentially serving as a valuable tool for imaging tissue pathophysiology.

  8. Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues.

    Science.gov (United States)

    Tzoumas, Stratis; Nunes, Antonio; Olefir, Ivan; Stangl, Stefan; Symvoulidis, Panagiotis; Glasl, Sarah; Bayer, Christine; Multhoff, Gabriele; Ntziachristos, Vasilis

    2016-06-30

    Light propagating in tissue attains a spectrum that varies with location due to wavelength-dependent fluence attenuation, an effect that causes spectral corruption. Spectral corruption has limited the quantification accuracy of optical and optoacoustic spectroscopic methods, and impeded the goal of imaging blood oxygen saturation (sO2) deep in tissues; a critical goal for the assessment of oxygenation in physiological processes and disease. Here we describe light fluence in the spectral domain and introduce eigenspectra multispectral optoacoustic tomography (eMSOT) to account for wavelength-dependent light attenuation, and estimate blood sO2 within deep tissue. We validate eMSOT in simulations, phantoms and animal measurements and spatially resolve sO2 in muscle and tumours, validating our measurements with histology data. eMSOT shows substantial sO2 accuracy enhancement over previous optoacoustic methods, potentially serving as a valuable tool for imaging tissue pathophysiology.

  9. Effect of blood glucose levels on image quality in 18F fluorodeoxyglucose scanning - a case report

    International Nuclear Information System (INIS)

    Szeto, E.; Keane, J.

    2000-01-01

    Full text: In December last year, a 71-year-old gentleman presented to the Nuclear Medicine Department at St Vincent's Hospital, Sydney for an FDG coincidence detection positron emission scan. The patient had cancer of the lung with a large lesion in the left upper lobe and a small lesion in the right middle lobe. On initial investigation, this patient had a blood sugar level of 17mmol/L which was eventually reduced to 6.7mmol/L just prior to scanning. The patient was then asked to return to be rescanned without his blood sugar levels being adjusted. Just prior to his second scan, his blood sugar level was 15.4mmollL. The aim of the initial scan being repeated was to see just how important a role blood sugar levels play in the quality of a Co Pet scan. The first scan showed excellent image quality while the repeated scan showed markedly inferior image quality due to unwanted soft tissue FDG uptake. In conclusion, blood sugar levels play a significant role in output image quality in FDG coincidence detection positron emission scanning. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  10. Fine structures and ion images on fresh frozen dried ultrathin sections by transmission electron and scanning ion microscopy

    International Nuclear Information System (INIS)

    Takaya, K.; Okabe, M.; Sawataishi, M.; Takashima, H.; Yoshida, T.

    2003-01-01

    Ion microscopy (IM) of air-dried or freeze-dried cryostat and semi-thin cryosections has provided ion images of elements and organic substances in wide areas of the tissue. For reproducible ion images by a shorter time of exposure to the primary ion beam, fresh frozen dried ultrathin sections were prepared by freezing the tissue in propane chilled with liquid nitrogen, cryocut at 60 nm, mounted on grids and silicon wafer pieces, and freeze-dried. Rat Cowper gland and sciatic nerve, bone marrow of the rat administered of lithium carbonate, tree frog and African toad spleen and buffy coat of atopic dermatitis patients were examined. Fine structures and ion images of the corresponding areas in the same or neighboring sections were observed by transmission electron microscopy (TEM) followed by sector type and time-of-flight type IM. Cells in the buffy coat contained larger amounts of potassium and magnesium while plasma had larger amounts of sodium and calcium. However, in the tissues, lithium, sodium, magnesium, calcium and potassium were distributed in the cell and calcium showed a granular appearance. A granular cell of the tree frog spleen contained sodium and potassium over the cell and magnesium and calcium were confined to granules

  11. Nonlinear optical microscopy for histology of fresh normal and cancerous pancreatic tissues.

    Directory of Open Access Journals (Sweden)

    Wenyan Hu

    Full Text Available BACKGROUND: Pancreatic cancer is a lethal disease with a 5-year survival rate of only 1-5%. The acceleration of intraoperative histological examination would be beneficial for better management of pancreatic cancer, suggesting an improved survival. Nonlinear optical methods based on two-photon excited fluorescence (TPEF and second harmonic generation (SHG of intrinsic optical biomarkers show the ability to visualize the morphology of fresh tissues associated with histology, which is promising for real-time intraoperative evaluation of pancreatic cancer. METHODOLOGY/PRINCIPAL FINDINGS: In order to investigate whether the nonlinear optical imaging methods have the ability to characterize pancreatic histology at cellular resolution, we studied different types of pancreatic tissues by using label-free TPEF and SHG. Compared with other routine methods for the preparation of specimens, fresh tissues without processing were found to be most suitable for nonlinear optical imaging of pancreatic tissues. The detailed morphology of the normal rat pancreas was observed and related with the standard histological images. Comparatively speaking, the preliminary images of a small number of chemical-induced pancreatic cancer tissues showed visible neoplastic differences in the morphology of cells and extracellular matrix. The subcutaneous pancreatic tumor xenografts were further observed using the nonlinear optical microscopy, showing that most cells are leucocytes at 5 days after implantation, the tumor cells begin to proliferate at 10 days after implantation, and the extracellular collagen fibers become disordered as the xenografts grow. CONCLUSIONS/SIGNIFICANCE: In this study, nonlinear optical imaging was used to characterize the morphological details of fresh pancreatic tissues for the first time. We demonstrate that it is possible to provide real-time histological evaluation of pancreatic cancer by the nonlinear optical methods, which present an

  12. Magnetic resonance imaging as a diagnostic method for assessing function. New procedures for the non-invasive quantification of cerebral blood volume and blood flow

    International Nuclear Information System (INIS)

    Gueckel, F.; Rempp, K.; Becker, G.; Koepke, J.; Loose, R.; Brix, G.

    1994-01-01

    This paper presents a brief introduction to the current status of cerebral blood volume and blood flow imaging with magnetic resonance imaging (MRI) techniques. A new method for the quantitative assessment of regional cerebral blood volume (rCBV) and regional cerebral blood flow (rCBF) on the basis of the indicator dilution theory is described and preliminary quantitative results from healthy volunteers are presented. The mean values for the rCBV are 8,27±1,85 ml/100 g for grey matter and 3,78±1,34 ml/100 g for white matter. The mean values for the rCBF are 44,8±11,29 ml/min/100 g for the grey matter and 20,88±8,42 ml/min/100 g for the white matter. These results are in good agreement with PET results from the literature. (orig.) [de

  13. The routine use of fresh frozen plasma in operations with cardiopulmonary bypass is not justified

    NARCIS (Netherlands)

    Consten, E. C.; Henny, C. P.; Eijsman, L.; Dongelmans, D. A.; van Oers, M. H.

    1996-01-01

    BACKGROUND: The negative influence of cardiopulmonary bypass on hemostasis has been documented. Although abnormalities in platelet function are reported as the major cause of postoperative blood loss related to this hemostasis defect, fresh frozen plasma is often used in operations with

  14. Continuous blood pressure recordings simultaneously with functional brain imaging: studies of the glymphatic system

    Science.gov (United States)

    Zienkiewicz, Aleksandra; Huotari, Niko; Raitamaa, Lauri; Raatikainen, Ville; Ferdinando, Hany; Vihriälä, Erkki; Korhonen, Vesa; Myllylä, Teemu; Kiviniemi, Vesa

    2017-03-01

    The lymph system is responsible for cleaning the tissues of metabolic waste products, soluble proteins and other harmful fluids etc. Lymph flow in the body is driven by body movements and muscle contractions. Moreover, it is indirectly dependent on the cardiovascular system, where the heart beat and blood pressure maintain force of pressure in lymphatic channels. Over the last few years, studies revealed that the brain contains the so-called glymphatic system, which is the counterpart of the systemic lymphatic system in the brain. Similarly, the flow in the glymphatic system is assumed to be mostly driven by physiological pulsations such as cardiovascular pulses. Thus, continuous measurement of blood pressure and heart function simultaneously with functional brain imaging is of great interest, particularly in studies of the glymphatic system. We present our MRI compatible optics based sensing system for continuous blood pressure measurement and show our current results on the effects of blood pressure variations on cerebral brain dynamics, with a focus on the glymphatic system. Blood pressure was measured simultaneously with near-infrared spectroscopy (NIRS) combined with an ultrafast functional brain imaging (fMRI) sequence magnetic resonance encephalography (MREG, 3D brain 10 Hz sampling rate).

  15. Breath-hold dark-blood T{sub 2}-weighted MR imaging of the heart. Estimation of optimum preset repetition time

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, Toshiharu; Yamada, Naoaki; Yamasaki, Hidetoshi; Kita, Yoshinobu; Fujii, Hiroshi [National Cardiovascular Center, Suita, Osaka (Japan)

    1999-03-01

    It has recently become possible to obtain T{sub 2}-weighted images using turbo spin echo with a preparation pulse to inhibit the signal from flowing blood (dark blood turbo spin echo: DB-TSE) during breath holding. In order to obtain higher-quality T{sub 2}-weighted images of the heart, we assessed the optimum preset repetition time (TR preset), the interval between the dark blood preparation pulse and the end of data acquisition on DB-TSE. DB-TSE left ventricular short-axis images were obtained with varying TR presets in eight volunteers. Signal intensity was measured for the myocardium and blood in the left ventricular cavity, and the signal intensity ratio of myocardium to blood was calculated. The optimum TR preset was determined so as to give the highest signal intensity ratio of myocardium to blood. A comparison was made of the myocardium-to-blood ratios between the eight volunteers and nine patients. The optimum TR preset changed according to the cardiac cycle. By using the optimum TR preset, we obtained the peak signal intensity ratios in the volunteers and the patients. By using DB-TSE with the optimum TR preset for the cardiac cycle, we can obtain better quality T{sub 2}-weighted images of the heart. (author)

  16. A Fully Automatic Fresh Apple Juicer: Peeling, Coring, Slicing and Juicing

    Directory of Open Access Journals (Sweden)

    Hu Fuwen

    2017-01-01

    Full Text Available With the fresh apple juice as an example, a fully automatic and intelligent juicer prototype was built via the integrated application of servo positioning modules, human-machine interface, image vision sensor system and 3D printing. All steps including peeling, coring, slicing and juicing were achieved automatically. The challenging technical problems about the identification and orientation of apple core, and adaptive peeling were settled creatively. The trial operation results illustrated that the fresh apple juice can be produced without manual intervention and the system has potential application in the crowded sites, such as mall, school, restaurant and hospital.

  17. Intraoperative laser speckle contrast imaging for monitoring cerebral blood flow: results from a 10-patient pilot study

    Science.gov (United States)

    Richards, Lisa M.; Weber, Erica L.; Parthasarathy, Ashwin B.; Kappeler, Kaelyn L.; Fox, Douglas J.; Dunn, Andrew K.

    2012-02-01

    Monitoring cerebral blood flow (CBF) during neurosurgery can provide important physiological information for a variety of surgical procedures. Although multiple intraoperative vascular monitoring technologies are currently available, a quantitative method that allows for continuous monitoring is still needed. Laser speckle contrast imaging (LSCI) is an optical imaging method with high spatial and temporal resolution that has been widely used to image CBF in animal models in vivo. In this pilot clinical study, we adapted a Zeiss OPMI Pentero neurosurgical microscope to obtain LSCI images by attaching a camera and a laser diode. This LSCI adapted instrument has been used to acquire full field flow images from 10 patients during tumor resection procedures. The patient's ECG was recorded during acquisition and image registration was performed in post-processing to account for pulsatile motion artifacts. Digital photographs confirmed alignment of vasculature and flow images in four cases, and a relative change in blood flow was observed in two patients after bipolar cautery. The LSCI adapted instrument has the capability to produce real-time, full field CBF image maps with excellent spatial resolution and minimal intervention to the surgical procedure. Results from this study demonstrate the feasibility of using LSCI to monitor blood flow during neurosurgery.

  18. Brain oxygen saturation assessment in neonates using T2-prepared blood imaging of oxygen saturation and near-infrared spectroscopy

    DEFF Research Database (Denmark)

    Alderliesten, Thomas; De Vis, Jill B; Lemmers, Petra Ma

    2017-01-01

    saturation in the sagittal sinus (R(2 )= 0.49, p = 0.023), but no significant correlations could be demonstrated with frontal and whole brain cerebral blood flow. These results suggest that measuring oxygen saturation by T2-prepared blood imaging of oxygen saturation is feasible, even in neonates. Strong...... sinus. A strong linear relation was found between the oxygen saturation measured by magnetic resonance imaging and the oxygen saturation measured by near-infrared spectroscopy (R(2 )= 0.64, p ..., and magnetic resonance imaging measures of frontal cerebral blood flow, whole brain cerebral blood flow and venous oxygen saturation in the sagittal sinus (R(2 )= 0.71, 0.50, 0.65; p 

  19. Application of LASCA imaging for detection of disorders of blood microcirculation in chicken embryo, infected by Chlamydia trachomatis

    Science.gov (United States)

    Ulianova, Onega; Subbotina, Irina; Filonova, Nadezhda; Zaitsev, Sergey; Saltykov, Yury; Polyanina, Tatiana; Lyapina, Anna; Ulyanov, Sergey; Larionova, Olga; Feodorova, Valentina

    2018-04-01

    Methods of t-LASCA and s-LASCA imaging have been firstly adapted to the problem of monitoring of blood microcirculation in chicken embryo model. Set-up for LASCA imaging of chicken embryo is mounted. Disorders of blood microcirculation in embryonated chicken egg, infected by Chlamydia trachomatis, are detected. Speckle-imaging technique is compared with white-light ovoscopy and new method of laser ovoscopy, based on the scattering of coherent light, advantages of LASCA imaging for the early detection of developmental process of chlamydial agent is demonstrated.

  20. Relevancy of Serum Calcium in Predicting Blood Product Transfusion in Trauma

    Science.gov (United States)

    2017-08-10

    collection of information, including suggestions for reducing this burden to Department of Defense, Washington Headquarters Services , Directorate for...to arrive from the blood bank . In the military setting, where fresh whole blood may be available as a “walking blood bank ,” appropriate donors need

  1. Development of 99mTc-ethyl cysteinate dimer (Neurolite) for imaging brain blood flow in stroke and other disorders

    International Nuclear Information System (INIS)

    Liteplo, M.P.

    1992-01-01

    Compounds labeled with 99m Tc are widely used for imaging in diagnostic medicine to provide information on physiological functions of the body not obtainable with other imaging techniques that give primarily anatomical information, such as X-ray and magnetic resonance imaging. These radiopharmaceuticals are typically injected intravenously and allowed to distribute in the body; the patient is then imaged using a scintillation gamma camera. For example, in patients suspected of coronary artery disease, 99m Tc-Sestamibi (Cardiolite reg-sign) is injected into the blood stream during a stress test and is rapidly extracted by the heart muscle in proportion to its regional blood supply. The resulting images of the heart clearly distinguish areas of normal heart muscle form areas where the blood supply is compromised by coronary artery disease. In recent years, there has been considerable interest in the application of 99m Tc compounds to the diagnosis of brain diseases and disorders. This paper describes the development of 99m Tc-ethyl cysteinate dimer ( 99m Tc-ECD, Neurolite reg-sign) as a radiopharmaceutical for imaging the blood supply to the brain in patients with stroke or head trauma. In research, this agent is also useful in studying the effect of sensory stimuli, therapeutic drugs, and drugs of abuse on brain blood flow

  2. Imaging transient blood vessel fusion events in zebrafish by correlative volume electron microscopy.

    Directory of Open Access Journals (Sweden)

    Hannah E J Armer

    Full Text Available The study of biological processes has become increasingly reliant on obtaining high-resolution spatial and temporal data through imaging techniques. As researchers demand molecular resolution of cellular events in the context of whole organisms, correlation of non-invasive live-organism imaging with electron microscopy in complex three-dimensional samples becomes critical. The developing blood vessels of vertebrates form a highly complex network which cannot be imaged at high resolution using traditional methods. Here we show that the point of fusion between growing blood vessels of transgenic zebrafish, identified in live confocal microscopy, can subsequently be traced through the structure of the organism using Focused Ion Beam/Scanning Electron Microscopy (FIB/SEM and Serial Block Face/Scanning Electron Microscopy (SBF/SEM. The resulting data give unprecedented microanatomical detail of the zebrafish and, for the first time, allow visualization of the ultrastructure of a time-limited biological event within the context of a whole organism.

  3. Cardiac MRI. T2-mapping versus T2-weighted dark-blood TSE imaging for myocardial edema visualization in acute myocardial infarction

    International Nuclear Information System (INIS)

    Nassenstein, K.; Nensa, F.; Schlosser, T.; Umutlu, L.; Lauenstein, T.; Bruder, O.; Maderwald, S.; Ladd, M.E.

    2014-01-01

    Purpose: To assess the diagnostic accuracy of T2 mapping for the detection of myocardial edema in acute myocardial infarction (AMI), and to compare this diagnostic accuracy with that of the current standard for myocardial edema imaging, which is T2w dark-blood TSE imaging. Materials and Methods: 29 patients with AMI were examined at 1.5 T. For the visualization of myocardial edema, T2 maps, calculated from three T2w SSFP images, and T2w dark-blood TSE images were acquired in standard short- and long-axis views. Cine SSFP images were acquired for the analysis of left ventricular (LV) function and late gadolinium enhancement images (LGE) for the visualization of myocardial necrosis. The T2 maps as well as the T2w dark-blood TSE images were evaluated twice independently from the cine SSFP and LGE images. The presence or absence of myocardial edema was rated visually for each LV segment. As the standard of reference, the infarct zone was defined based on the cine SSFP and the LGE images. Results: In this segment-based analysis, T2 mapping showed a sensitivity of 82 % and a specificity of 94 % for the detection of edema in the infarct zone. T2w dark-blood TSE imaging revealed a sensitivity of 50 % and a specificity of 98 %. T2 mapping showed a higher intra-rater agreement compared to T2w dark-blood TSE imaging (κ: 0.87 vs. 0.76). Conclusions: T2 mapping allows for the visualization of myocardial edema in AMI with a high sensitivity and specificity, and features better diagnostic accuracy in terms of a higher sensitivity compared to T2w dark-blood TSE imaging. (orig.)

  4. Measurement of renal blood flow by phase-contrast magnetic resonance imaging during septic acute kidney injury: a pilot investigation.

    Science.gov (United States)

    Prowle, John R; Molan, Maurice P; Hornsey, Emma; Bellomo, Rinaldo

    2012-06-01

    In septic patients, decreased renal perfusion is considered to play a major role in the pathogenesis of acute kidney injury. However, the accurate measurement of renal blood flow in such patients is problematic and invasive. We sought to overcome such obstacles by measuring renal blood flow in septic patients with acute kidney injury using cine phase-contrast magnetic resonance imaging. Pilot observational study. University-affiliated general adult intensive care unit. Ten adult patients with established septic acute kidney injury and 11 normal volunteers. Cine phase-contrast magnetic resonance imaging measurement of renal blood flow and cardiac output. The median age of the study patients was 62.5 yrs and eight were male. At the time of magnetic resonance imaging, eight patients were mechanically ventilated, nine were on continuous hemofiltration, and five required vasopressors. Cine phase-contrast magnetic resonance imaging examinations were carried out without complication. Median renal blood flow was 482 mL/min (range 335-1137) in septic acute kidney injury and 1260 mL/min (range 791-1750) in healthy controls (p = .003). Renal blood flow indexed to body surface area was 244 mL/min/m2 (range 165-662) in septic acute kidney injury and 525 mL/min/m2 (range 438-869) in controls (p = .004). In patients with septic acute kidney injury, median cardiac index was 3.5 L/min/m2 (range 1.6-8.7), and median renal fraction of cardiac output was only 7.1% (range 4.4-10.8). There was no rank correlation between renal blood flow index and creatinine clearance in patients with septic acute kidney injury (r = .26, p = .45). Cine phase-contrast magnetic resonance imaging can be used to noninvasively and safely assess renal perfusion during critical illness in man. Near-simultaneous accurate measurement of cardiac output enables organ blood flow to be assessed in the context of the global circulation. Renal blood flow seems consistently reduced as a fraction of cardiac output in

  5. Personal identification based on blood vessels of retinal fundus images

    Science.gov (United States)

    Fukuta, Keisuke; Nakagawa, Toshiaki; Hayashi, Yoshinori; Hatanaka, Yuji; Hara, Takeshi; Fujita, Hiroshi

    2008-03-01

    Biometric technique has been implemented instead of conventional identification methods such as password in computer, automatic teller machine (ATM), and entrance and exit management system. We propose a personal identification (PI) system using color retinal fundus images which are unique to each individual. The proposed procedure for identification is based on comparison of an input fundus image with reference fundus images in the database. In the first step, registration between the input image and the reference image is performed. The step includes translational and rotational movement. The PI is based on the measure of similarity between blood vessel images generated from the input and reference images. The similarity measure is defined as the cross-correlation coefficient calculated from the pixel values. When the similarity is greater than a predetermined threshold, the input image is identified. This means both the input and the reference images are associated to the same person. Four hundred sixty-two fundus images including forty-one same-person's image pairs were used for the estimation of the proposed technique. The false rejection rate and the false acceptance rate were 9.9×10 -5% and 4.3×10 -5%, respectively. The results indicate that the proposed method has a higher performance than other biometrics except for DNA. To be used for practical application in the public, the device which can take retinal fundus images easily is needed. The proposed method is applied to not only the PI but also the system which warns about misfiling of fundus images in medical facilities.

  6. Fast Blood Vector Velocity Imaging: Simulations and Preliminary In Vivo Results

    DEFF Research Database (Denmark)

    Udesen, Jesper; Gran, Fredrik; Hansen, Kristoffer Lindskov

    2007-01-01

    for each pulse emission. 2) The transmitted pulse consists of a 13 bit Barker code which is transmitted simultaneously from each transducer element. 3) The 2-D vector velocity of the blood is found using 2-D speckle tracking between segments in consecutive speckle images. III Results: The method was tested...

  7. Rapid dual-tracer PTSM+ATSM PET imaging of tumour blood flow and hypoxia: a simulation study

    International Nuclear Information System (INIS)

    Rust, T C; Kadrmas, D J

    2006-01-01

    Blood flow and hypoxia are interrelated aspects of physiology that affect cancer treatment and response. Cu-PTSM and Cu-ATSM are related PET tracers for blood flow and hypoxia, and the ability to rapidly image both tracers in a single scan would bring several advantages over conventional single-tracer techniques. Using dynamic imaging with staggered injections, overlapping signals for multiple PET tracers may be recovered utilizing information from kinetics and radioactive decay. In this work, rapid dual-tracer PTSM+ATSM PET was simulated and tested as a function of injection delay, order and relative dose for several copper isotopes, and the results were compared relative to separate single-tracer data. Time-activity curves representing a broad range of tumour blood flow and hypoxia levels were simulated, and parallel dual-tracer compartment modelling was used to recover the signals for each tracer. The main results were tested further using a torso phantom simulation of PET tumour imaging. Using scans as short as 30 minutes, the dual-tracer method provided measures of blood flow and hypoxia similar to single-tracer imaging. The best performance was obtained by injecting PTSM first and using a somewhat higher dose for ATSM. Comparable results for different copper isotopes suggest that tracer kinetics with staggered injections play a more important role than radioactive decay in the signal separation process. Rapid PTSM+ATSM PET has excellent potential for characterizing both tumour blood flow and hypoxia in a single, fast scan, provided that technological hurdles related to algorithm development and routine use can be overcome

  8. Synthesis of fluorine-18 radio-labeled serum albumins for PET blood pool imaging

    International Nuclear Information System (INIS)

    Basuli, Falguni; Li, Changhui; Xu, Biying; Williams, Mark; Wong, Karen; Coble, Vincent L.; Vasalatiy, Olga; Seidel, Jurgen; Green, Michael V.; Griffiths, Gary L.; Choyke, Peter L.; Jagoda, Elaine M.

    2015-01-01

    We sought to develop a practical, reproducible and clinically translatable method of radiolabeling serum albumins with fluorine-18 for use as a PET blood pool imaging agent in animals and man. Fluorine-18 radiolabeled fluoronicotinic acid-2,3,5,6-tetrafluorophenyl ester, [ 18 F]F-Py-TFP was prepared first by the reaction of its quaternary ammonium triflate precursor with [ 18 F]tetrabutylammonium fluoride ([ 18 F]TBAF) according to a previously published method for peptides, with minor modifications. The incubation of [ 18 F]F-Py-TFP with rat serum albumin (RSA) in phosphate buffer (pH 9) for 15 min at 37–40 °C produced fluorine-18-radiolabeled RSA and the product was purified using a mini-PD MiniTrap G-25 column. The overall radiochemical yield of the reaction was 18–35% (n = 30, uncorrected) in a 90-min synthesis. This procedure, repeated with human serum albumin (HSA), yielded similar results. Fluorine-18-radiolabeled RSA demonstrated prolonged blood retention (biological half-life of 4.8 hours) in healthy awake rats. The distribution of major organ radioactivity remained relatively unchanged during the 4 hour observation periods either by direct tissue counting or by dynamic PET whole-body imaging except for a gradual accumulation of labeled metabolic products in the bladder. This manual method for synthesizing radiolabeled serum albumins uses fluorine-18, a widely available PET radionuclide, and natural protein available in both pure and recombinant forms which could be scaled up for widespread clinical applications. These preclinical biodistribution and PET imaging results indicate that [ 18 F]RSA is an effective blood pool imaging agent in rats and might, as [ 18 F]HSA, prove similarly useful as a clinical imaging agent

  9. Synthesis of fluorine-18 radio-labeled serum albumins for PET blood pool imaging.

    Science.gov (United States)

    Basuli, Falguni; Li, Changhui; Xu, Biying; Williams, Mark; Wong, Karen; Coble, Vincent L; Vasalatiy, Olga; Seidel, Jurgen; Green, Michael V; Griffiths, Gary L; Choyke, Peter L; Jagoda, Elaine M

    2015-03-01

    We sought to develop a practical, reproducible and clinically translatable method of radiolabeling serum albumins with fluorine-18 for use as a PET blood pool imaging agent in animals and man. Fluorine-18 radiolabeled fluoronicotinic acid-2,3,5,6-tetrafluorophenyl ester, [(18)F]F-Py-TFP was prepared first by the reaction of its quaternary ammonium triflate precursor with [(18)F]tetrabutylammonium fluoride ([(18)F]TBAF) according to a previously published method for peptides, with minor modifications. The incubation of [(18)F]F-Py-TFP with rat serum albumin (RSA) in phosphate buffer (pH9) for 15 min at 37-40 °C produced fluorine-18-radiolabeled RSA and the product was purified using a mini-PD MiniTrap G-25 column. The overall radiochemical yield of the reaction was 18-35% (n=30, uncorrected) in a 90-min synthesis. This procedure, repeated with human serum albumin (HSA), yielded similar results. Fluorine-18-radiolabeled RSA demonstrated prolonged blood retention (biological half-life of 4.8 hours) in healthy awake rats. The distribution of major organ radioactivity remained relatively unchanged during the 4 hour observation periods either by direct tissue counting or by dynamic PET whole-body imaging except for a gradual accumulation of labeled metabolic products in the bladder. This manual method for synthesizing radiolabeled serum albumins uses fluorine-18, a widely available PET radionuclide, and natural protein available in both pure and recombinant forms which could be scaled up for widespread clinical applications. These preclinical biodistribution and PET imaging results indicate that [(18)F]RSA is an effective blood pool imaging agent in rats and might, as [(18)F]HSA, prove similarly useful as a clinical imaging agent. Published by Elsevier Inc.

  10. Molecular imaging of tumor blood vessels in prostate cancer.

    Science.gov (United States)

    Tilki, Derya; Seitz, Michael; Singer, Bernhard B; Irmak, Ster; Stief, Christian G; Reich, Oliver; Ergün, Süleyman

    2009-05-01

    In the past three decades many efforts have been undertaken to understand the mechanisms of tumor angiogenesis. The introduction of anti-angiogenic drugs in tumor therapy during the last few years necessitates the establishment of new techniques enabling molecular imaging of tumor vascular remodelling. The determination of tumor size as commonly used is not appropriate since the extended necrosis under anti-angiogenic therapy does not necessarily result in the reduction of tumor diameter. The basis for the molecular imaging of tumor blood vessels is the remodelling of the tumor vessels under anti-angiogenic therapy which obviously occurs at an early stage and seems to be a convincing parameter. Beside the enormous progress in this field during the last few years the resolution is still not high enough to evaluate the remodelling of the micro tumor vessels. New imaging approaches combining specific molecular markers for tumor vessels with the different imaging techniques are needed to overcome this issue as exemplarily discussed for prostate cancer in this review. Molecular contrast agents targeting the vasculature will allow clinicians the visualization of vascular remodelling processes taking place under anti-angiogenic therapy and improve tumor diagnosis and follow-up.

  11. Orthogonal Views of Coronary Vessels: A Method for Imaging the Delivery of Blood Cardioplegia Using Transesophageal Echocardiography.

    Science.gov (United States)

    Maracaja Neto, Luiz F; Modak, Raj; Schonberger, Robert B

    2017-04-01

    Coronary blood flow can be disrupted during cardiac interventions such as mitral valve surgeries, left atrial appendage ligation, transcatheter aortic valve implantation, and aortic procedures involving reimplantation of coronary buttons. Although difficult to accomplish, coronary imaging using transesophageal echocardiography can be performed by the use of orthogonal imaging with the ability for real-time tilt for angle adjustment. The technique described herein allows imaging of the right coronary artery, left main coronary artery bifurcation, left anterior descending, and circumflex coronary arteries. The imaging is facilitated by acquisition during the delivery of blood cardioplegia. Coronary sinus and great cardiac vein imaging also can be obtained during the delivery of retrograde cardioplegia. Although further studies are needed, this imaging technique may prove useful in procedures where coronary flow disruption is suspected or as an additional parameter to confirm delivery of cardioplegia.

  12. Intelligent Color Vision System for Ripeness Classification of Oil Palm Fresh Fruit Bunch

    OpenAIRE

    Fadilah, Norasyikin; Mohamad-Saleh, Junita; Halim, Zaini Abdul; Ibrahim, Haidi; Ali, Syed Salim Syed

    2012-01-01

    Ripeness classification of oil palm fresh fruit bunches (FFBs) during harvesting is important to ensure that they are harvested during optimum stage for maximum oil production. This paper presents the application of color vision for automated ripeness classification of oil palm FFB. Images of oil palm FFBs of type DxP Yangambi were collected and analyzed using digital image processing techniques. Then the color features were extracted from those images and used as the inputs for Artificial Ne...

  13. MR imaging of postoperative change of dura mater of rabbits; Effect of contrast enhancement of dura mater and correlation with pathological findings

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Fumiaki (Kanazawa Univ. (Japan). School of Medicine)

    1993-01-01

    To explain the mechanism of benign postoperative dural enhancement, the author made experimental model of rabbit's subdual hematoma and performed magnetic resonance (MR) imaging with gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA). On plain T1-weighted images, infused blood or blood cells could not be detected immediately after surgery. On follow up plain T1-weighted images, the infused blood could be identified in only a case with 1 cc blood infusion. Marked dural enhancement could be seen immediately after surgery and continued three to fourteen days after 1 cc or 0.1 cc blood or 0.1 cc red blood cells infusion. To the contrary, no definite dural enhancement could be seen in the cases with plasma or saline infusion. Subdural red blood cells were required for dural enhancement immediately after surgery. Pathological findings revealed three types of reaction to infused blood: newly formed capillarization with fresh hemorrhage from the capillaries; subdural hematoma and no reaction. After vanishment of dural enhancement, pathological findings of the specimens were identical to that of normal dura. Dural enhancement may be induced by increased permeability of the dura associated with subdural hematoma and/or the extravasation of the contrast from newly formed capillaries. (author).

  14. Fresh Slice Self-Seeding and Fresh Slice Harmonic Lasing at LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Amann, J.W. [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2018-04-01

    We present results from the successful demonstration of fresh slice self-seeding at the Linac Coherent Light Source (LCLS).* The performance is compared with SASE and regular self-seeding at photon energy of 5.5 keV, resulting in a relative average brightness increase of a factor of 12 and a factor of 2 respectively. Following this proof-of-principle we discuss the forthcoming plans to use the same technique** for fresh slice harmonic lasing in an upcoming experiment. The demonstration of fresh slice harmonic lasing provides an attractive solution for future XFELs aiming to achieve high efficiency, high brightness X-ray pulses at high photon energies (>12 keV).***

  15. Adaptable three-dimensional Monte Carlo modeling of imaged blood vessels in skin

    Science.gov (United States)

    Pfefer, T. Joshua; Barton, Jennifer K.; Chan, Eric K.; Ducros, Mathieu G.; Sorg, Brian S.; Milner, Thomas E.; Nelson, J. Stuart; Welch, Ashley J.

    1997-06-01

    In order to reach a higher level of accuracy in simulation of port wine stain treatment, we propose to discard the typical layered geometry and cylindrical blood vessel assumptions made in optical models and use imaging techniques to define actual tissue geometry. Two main additions to the typical 3D, weighted photon, variable step size Monte Carlo routine were necessary to achieve this goal. First, optical low coherence reflectometry (OLCR) images of rat skin were used to specify a 3D material array, with each entry assigned a label to represent the type of tissue in that particular voxel. Second, the Monte Carlo algorithm was altered so that when a photon crosses into a new voxel, the remaining path length is recalculated using the new optical properties, as specified by the material array. The model has shown good agreement with data from the literature. Monte Carlo simulations using OLCR images of asymmetrically curved blood vessels show various effects such as shading, scattering-induced peaks at vessel surfaces, and directionality-induced gradients in energy deposition. In conclusion, this augmentation of the Monte Carlo method can accurately simulate light transport for a wide variety of nonhomogeneous tissue geometries.

  16. Relationship between dynamic infrared thermal images and blood perfusion rate of the tongue in anaemia patients

    Science.gov (United States)

    Xie, Haiwei; Zhang, Yan

    2018-03-01

    The relationship between dynamic infrared (IR) thermal images and blood perfusion rate of the tongues of anaemia patients was investigated. Blood perfusion rates at multiple locations on the tongues of 62 anaemia patients and 70 control subjects were measured. For both groups of subjects, dynamic IR thermal images were also recorded within 16 s after the mouth opened. The results showed that the blood perfusion rates at different sites (apex, middle, left side and right side) on the tongues in anaemia patients (3.49, 3.71, 3.85 and 3.77 kg/s m-3) were significantly lower than those at the corresponding sites in control subjects (4.45, 4.66, 4.81 and 4.70 kg/s m-3). After the mouth opened, the tongue temperature decreased more rapidly in anaemia patients than in control subjects. To analyse the heat transfer mechanism, a transient heat transfer model of the tongue was developed. The tongue temperatures in anaemia patients and control subjects were calculated using this model and compared to the tongue temperatures measured by the IR thermal imager. The relationship between the tongue surface temperature and the tongue blood perfusion rate was analysed. The simulation results indicated that the low blood perfusion rate and the correlated changes in anaemia patients can cause faster temperature decreases of the tongue surface.

  17. Advance prediction of mild cognitive impairment (MCI) using 99mTc-ECD SPECT brain blood flow imaging

    International Nuclear Information System (INIS)

    Kawasaki, Yohsuke

    2008-01-01

    Mild Cognitive Impairment (MCI) is considered as a precursor state of Alzheimer disease (AD). Single photon emission computed tomography (SPECT) brain blood flow imaging was investigated in MCI and it's relevance to the prognosis of MCI was evaluated in an attempt define the characteristics of brain blood flow imaging of MCI (amnestic MCI; aMCI) converting to AD. Ninety-two patients over 60 years old with amnesia were studied. 99m Tc-ethyl cysteinate dimer (ECD) SPECT brain blood flow examinations of the subject under drug-free conditions were conducted and imaging was analyzed according to the first clinical diagnosis. Patients given a diagnosis of MCI on the first clinical diagnosis, were examined again after 2 years and the SPECT imaging before 2 years previously was classified and analyzed. Of them, there were 35 MCI patients, converting of 13 AD patients (37.1%; aMCI), 10 MCI patients (28.6%; non-converter), 4 depression patients (11.4%; Depression type MCI (dMCI)), 1 Geriatric psychosis patient, but 7 patients dropped out. In the aMCI group, relative hypoperfusion was recognized in the posterior cingulate and the precuneus. In the dMCI group, relative hypoperfusion was recognized in the dorsolateral prefrontal cortex (DLPFC) and the anterior cingulate. In the non-converter group, relative hypoperfusion was recognized in the basal forebrain. The hypoperfusion of the precuneus in aMCI, and the hypoperfusion of the right frontal lobe (DLPFC, dorsal-anterior cingulate) in dMCI were characteristic brain blood-flow abnormalities. We believe 99m Tc-ECD SPECT brain blood flow imaging to be useful in the diagnosis of aMCI and in the early detection of depression. (author)

  18. Manage your blood sugar (image)

    Science.gov (United States)

    Checking your blood sugar levels often and writing down the results will tell you how well you are managing your diabetes so you ... possible. The best times to check your blood sugar are before meals and at bedtime. Your blood ...

  19. Usage of CO2 microbubbles as flow-tracing contrast media in X-ray dynamic imaging of blood flows.

    Science.gov (United States)

    Lee, Sang Joon; Park, Han Wook; Jung, Sung Yong

    2014-09-01

    X-ray imaging techniques have been employed to visualize various biofluid flow phenomena in a non-destructive manner. X-ray particle image velocimetry (PIV) was developed to measure velocity fields of blood flows to obtain hemodynamic information. A time-resolved X-ray PIV technique that is capable of measuring the velocity fields of blood flows under real physiological conditions was recently developed. However, technical limitations still remained in the measurement of blood flows with high image contrast and sufficient biocapability. In this study, CO2 microbubbles as flow-tracing contrast media for X-ray PIV measurements of biofluid flows was developed. Human serum albumin and CO2 gas were mechanically agitated to fabricate CO2 microbubbles. The optimal fabricating conditions of CO2 microbubbles were found by comparing the size and amount of microbubbles fabricated under various operating conditions. The average size and quantity of CO2 microbubbles were measured by using a synchrotron X-ray imaging technique with a high spatial resolution. The quantity and size of the fabricated microbubbles decrease with increasing speed and operation time of the mechanical agitation. The feasibility of CO2 microbubbles as a flow-tracing contrast media was checked for a 40% hematocrit blood flow. Particle images of the blood flow were consecutively captured by the time-resolved X-ray PIV system to obtain velocity field information of the flow. The experimental results were compared with a theoretically amassed velocity profile. Results show that the CO2 microbubbles can be used as effective flow-tracing contrast media in X-ray PIV experiments.

  20. Quantification of renal cortical blood flow using factor analysis of O-15 water dynamic PET images

    International Nuclear Information System (INIS)

    Seo, Kang Jun; Ahn, Ji Young; Lee, Jae Sung; Paeng, Jin Chul; Cheon, Gi Jeong; Lee, Dong Soo; Noh, Tae Won; Chung, June Key; Lee, Myung Chul

    2000-01-01

    To obtain spatial distribution of renal factor images, input function, and regional tissue time-activity curve (TAC) from O-15 water dynamic PET images non-invasively, factor analysis (FA) was used. O-15 water dynamic PET scans were performed on 3 normal dogs (22 ∼ 29 kg) with the bolus injection of O-15 water (555 ∼ 740 Mbq). We performed FA on the masked dynamic images and obtained the pure TACs and the corresponding factor images. Microsphere experiment also was performed. 37MBq of microsphere labeled with Sc-46 was injected into the left ventricle. Arterial input functions derived from the PET images using FA were compared with the invasively derived arterial blood samples. The renal cortical blood flow using the TACs by FA was within the normal range of 1.23 ∼ 2.46 ml/min/g. In microsphere study, the renal cortical blood flow of left kidney by FA was 2.49±0.47 ml/min/g (1.81∼2.90 ml/min/g) and by microsphere was 2.52 ±0.19 ml/min/g (2.34 ∼2.68 ml/min/g). In right kidney, flow by FA was 2.02 ±0.32 ml/min/g (1.82∼2.49 ml/min/g) and by microsphere was 2.49 ±0.27 ml/min/g (2.02∼2.7). FA is a useful and robust method to extract input functions and tissue TACs from O-15 dynamic renal PET. Renal cortical blood flow can be estimated non-invasively using FA and it will be helpful for the assessment of renal functional disease

  1. Imaging local cerebral blood flow by xenon-enhanced computed tomography - technical optimization procedures

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, J.S.; Shinohara, T.; Imai, A.; Kobari, M.; Sakai, F.; Hata, T.; Oravez, W.T.; Timpe, G.M.; Deville, T.; Solomon, E.

    1988-08-01

    Methods are described for non-invasive, computer-assisted serial scanning throughout the human brain during eight minutes of inhalation of 27%-30% xenon gas in order to measure local cerebral blood flow (LCBF). Optimized xenon-enhanced computed tomography (XeCT) was achieved by 5-second scanning at one-minute intervals utilizing a state-of-the-art CT scanner and rapid delivery of xenon gas via a face mask. Values for local brain-blood partition coefficients (Llambda) measured in vivo were utilized to calculate LCBF values. Previous methods assumed Llambda values to be normal, introducing the risk of systematic errors, because Llambda values differ throughout normal brain and may be altered by disease. Color-coded maps of Llambda and LCBF values were formatted directly onto CT images for exact correlation of function with anatomic and pathologic observations (spatial resolution: 26.5 cubic mm). Results were compared among eight normal volunteers, aged between 50 and 88 years. Mean cortical gray matter blood flow was 46.3 +- 7.7, for subcortical gray matter it was 50.3 +- 13.2 and for white matter it was 18.8 +- 3.2. Modern CT scanners provide stability, improved signal to noise ratio and minimal radiation scatter. Combining these advantages with rapid xenon saturation of the blood provides correlations of Llambda and LCBF with images of normal and abnormal brain in a safe, useful and non-invasive manner.

  2. Storage time of platelet concentrates and risk of a positive blood culture

    DEFF Research Database (Denmark)

    Kreuger, Aukje L; Rostgaard, Klaus; Middelburg, Rutger A

    2018-01-01

    BACKGROUND: Concern of transfusion-transmitted bacterial infections has been the major hurdle to extend shelf life of platelet (PLT) concentrates. We aimed to investigate the association between storage time and risk of positive blood cultures at different times after transfusion. STUDY DESIGN...... AND METHODS: We performed a nationwide cohort study among PLT transfusion recipients in Denmark between 2010 and 2012, as recorded in the Scandinavian Donations and Transfusions (SCANDAT2) database. Linking with a nationwide database on blood cultures (MiBa), we compared the incidence of a positive blood......) of a positive blood culture the day after transfusion of at least one old PLT concentrate was 0.77 (95% confidence interval [CI], 0.54-1.09) compared to transfusion of fresh PLT concentrates. The incidence rate of a positive blood culture was lower the day after receiving one old compared to one fresh PLT...

  3. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization.

    Science.gov (United States)

    Pairleitner, H; Steiner, H; Hasenoehrl, G; Staudach, A

    1999-08-01

    To assess the feasibility of imaging low-velocity blood flow in adnexal masses by transvaginal three-dimensional power Doppler sonography, to analyze three-dimensional power Doppler sonography data sets with a new computer-assisted method and to test the reproducibility of the technique. A commercially available 5-MHz Combison 530 ultrasound system was used to perform three-dimensional power Doppler sonography transvaginally. A cube (= volume of interest) was defined enclosing the vessels of the cyst and the Cartesian characteristics were stored on a hard disk. This cube was analyzed using specially designed software. Five indices representing vascularization (the vascularization index (VI) or blood flow (the flow index (FI)) or both (the vascularization-flow index (VFI)) were calculated. The intraobserver repeatability of cube definition and scan repetition was assessed using Hartley's test for homogeneous variances. Interobserver agreement was assessed by the Pearson correlation coefficient. Imaging of vessels with low-velocity blood flow by three-dimensional power Doppler sonography and cube definition was possible in all adnexal massed studied. In some cases even induced non-vascular flow related to endometriosis was detected. The calculated F value with intraobserver repeated Cartesian file-saving ranged from 0 to 18.8, with intraobserver scan repetition from 4.74 to 24.8 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the calculated F value was 64. The interobserver correlation coefficient ranged between 0.83 and 0.92 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the correlation coefficient was less than 0.75. Vessels with low-velocity blood flow can be imaged using three-dimensional power Doppler sonography. Induced non-vascular flow was detected in endometriotic cyst fluid. Three-dimensional power Doppler sonography combined with the cube method gave reproducible information for all indices except VFI 2. These indices might prove to be a new predictor in all fields of

  4. Statistical image analysis of cerebral blood flow in moyamoya disease

    International Nuclear Information System (INIS)

    Yamada, Masaru; Yuzawa, Izumi; Suzuki, Sachio; Kurata, Akira; Fujii, Kiyotaka; Asano, Yuji

    2007-01-01

    The Summary of this study was to investigate pathophysiology of moyamoya disease, we analyzed brain single photon emission tomography (SPECT) images of patients with this disease by using interface software for a 3-dimensional (3D) data extraction format. Presenting symptoms were transient ischemic attack (TIA) in 21 patients and hemorrhage in 6 patients. All the patients underwent brain SPECT scan of 123 I-iofetamine (IMP) at rest and after acetazolamide challenge (17 mg/kg iv, 2-day method). Cerebral blood flow (CBF) was quantitatively measured using arterial blood sampling and an autoradiography model. The group of the patients who presented with TIAs showed decreased CBF in the frontal lobe at rest compared to that of patients with hemorrhage, but Z-score ((mean-patient data)/ standard deviation (SD)) did not reach statistical significance. Significant CBF decrease after acetazolamide challenge was observed in a wider cerebral cortical area in the TIA group than in the hemorrhagic group. The brain region of hemodynamic ischemia (stage II) correlated well with the responsible cortical area for clinical symptoms of TIA. A hemodynamic ischemia stage image clearly represented recovery of reserve capacity after bypass surgery. Statistical evaluation of SPECT may be useful to understand and clarify the pathophysiology of this disease. (author)

  5. A microfluidic chip for blood plasma separation using electro-osmotic flow control

    International Nuclear Information System (INIS)

    Jiang, Hai; Weng, Xuan; Chon, Chan Hee; Wu, Xudong; Li, Dongqing

    2011-01-01

    In this paper, a microfluidic-based chip with two straight microchannels and five branch microchannels was designed and tested to separate blood plasma from a small sample of fresh human blood. The electro-osmotic flow method was used to control the separation of blood plasma. Blood cell removal and blood plasma extraction were realized in experiments. The efficiency of extracting blood plasma can be as high as 26%

  6. Blood oxygenation level dependent (BOLD). Renal imaging. Concepts and applications; Blood Oxygenation Level Dependent (BOLD). Bildgebung der Nieren. Konzepte und Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Nissen, Johanna C.; Haneder, Stefan; Schoenberg, Stefan O.; Michaely, Henrik J. [Heidelberg Univ. Medizinische Fakultaet Mannheim (Germany). Inst. fuer Klinische Radiologie und Nuklearmedizin; Mie, Moritz B.; Zoellner, Frank G. [Heidelberg Univ. Medizinische Fakultaet Mannheim (DE). Inst. fuer Computerunterstuetzte Klinische Medizin (CKM)

    2010-07-01

    Many renal diseases as well as several pharmacons cause a change in renal blood flow and/or renal oxygenation. The blood oxygenation level dependent (BOLD) imaging takes advantage of local field inhomogeneities and is based on a T2{sup *}-weighted sequence. BOLD is a non-invasive method allowing an estimation of the renal, particularly the medullary oxygenation, and an indirect measurement of blood flow without administration of contrast agents. Thus, effects of different drugs on the kidney and various renal diseases can be controlled and observed. This work will provide an overview of the studies carried out so far and identify ways how BOLD can be used in clinical studies. (orig.)

  7. Laser speckle imaging of rat retinal blood flow with hybrid temporal and spatial analysis method

    Science.gov (United States)

    Cheng, Haiying; Yan, Yumei; Duong, Timothy Q.

    2009-02-01

    Noninvasive monitoring of blood flow in retinal circulation will reveal the progression and treatment of ocular disorders, such as diabetic retinopathy, age-related macular degeneration and glaucoma. A non-invasive and direct BF measurement technique with high spatial-temporal resolution is needed for retinal imaging. Laser speckle imaging (LSI) is such a method. Currently, there are two analysis methods for LSI: spatial statistics LSI (SS-LSI) and temporal statistical LSI (TS-LSI). Comparing these two analysis methods, SS-LSI has higher signal to noise ratio (SNR) and TSLSI is less susceptible to artifacts from stationary speckle. We proposed a hybrid temporal and spatial analysis method (HTS-LSI) to measure the retinal blood flow. Gas challenge experiment was performed and images were analyzed by HTS-LSI. Results showed that HTS-LSI can not only remove the stationary speckle but also increase the SNR. Under 100% O2, retinal BF decreased by 20-30%. This was consistent with the results observed with laser Doppler technique. As retinal blood flow is a critical physiological parameter and its perturbation has been implicated in the early stages of many retinal diseases, HTS-LSI will be an efficient method in early detection of retina diseases.

  8. Riboflavin-ultraviolet light pathogen reduction treatment does not impact the immunogenicity of murine red blood cells.

    Science.gov (United States)

    Tormey, Christopher A; Santhanakrishnan, Manjula; Smith, Nicole H; Liu, Jingchun; Marschner, Susanne; Goodrich, Raymond P; Hendrickson, Jeanne E

    2016-04-01

    Ultraviolet (UV) illumination/pathogen reduction effectively inactivates white blood cells (WBCs) in whole blood. Given that cotransfused WBCs may impact recipient immune responses, we hypothesized that pathogen reduction of whole blood may alter responses to RBC antigens. Transgenic mice expressing a model (HOD) antigen, authentic human (hGPA or KEL) antigens, or natural fluorescence (uGFP) on their RBCs were utilized as blood donors. Recipients were transfused with fresh whole blood to which riboflavin had been added or fresh whole blood treated by UV illumination/pathogen reduction treatment after the addition of riboflavin. Posttransfusion RBC recovery, survival, and alloimmunization were measured by flow cytometry. UV illumination/pathogen reduction treatment did not alter RBC antigen expression, and recipients of treated syngeneic RBCs had persistently negative direct antiglobulin tests. Greater than 75% of treated and untreated syngeneic RBCs were recovered 24 hours posttransfusion in all experiments, although alterations in the long-term posttransfusion survival of treated RBCs were observed. Treated and untreated KEL RBCs induced similar recipient alloimmune responses, with all recipients making anti-KEL glycoprotein immunoglobulins (p > 0.05). Alloimmune responses to treated HOD or hGPA RBCs were no different from untreated RBCs (p > 0.05). Pathogen inactivation treatment of fresh whole murine blood with riboflavin and UV illumination does not impact the rate or magnitude of RBC alloimmunization to three distinct RBC antigens. Further, UV illumination/pathogen reduction appears safe from an immunohematologic standpoint, with no immunogenic neoantigens detected on treated murine RBCs. Future studies with fresh and stored human RBCs are warranted to confirm these findings. © 2015 AABB.

  9. Donor Tracker: An Innovative Real-Time Tracking System for Blood ...

    African Journals Online (AJOL)

    In this paper, we explore the possibility of using location-aware computing to track blood donors in Mauritius and locate the nearest donor in cases of emergencies and whenever fresh blood is ... Keywords: Context-awareness, location-awareness, mobile and ubiquitous computing, location sensing technique, real-time.

  10. Evaluation of renal first pass blood flow with a functional image technique in hypertensive patients

    International Nuclear Information System (INIS)

    Ishibashi, Masatoshi; Morita, Seiichiro; Umezaki, Noriyoshi; Ohtake, Hisashi

    1988-01-01

    The renal circulation of patients with essential hypertension and renovascular hypertension was evaluated using 99m Tc-DTPA. The first renal peak count (the first C max ; FC max ), time phase distribution (the first T max ; FT max ), and blood velocity (the FC max /FT max ) were calculated by digital imaging. This yields a visual image of the renal circulation. We consider that the increase in the renal first pass blood flow in patients with essential hypertension is best observed pixel by pixel. The FC max and FC max /FT max images before and after treatment by percutaneous transluminal renal angioplasty in patients with renovascular hypertension clearly show its therapeutic effect. The FI technique, therefore, has the advantage that it can be performed at the same time as the conventional routine examinations of renal function. This makes it very useful clinically. (orig.)

  11. The prevalence and assessment of blood transfusions in newborns

    Directory of Open Access Journals (Sweden)

    Hajieh Borna

    2017-06-01

    Full Text Available Background: Blood transfusion is common in infants. Due to the weakened immune system of newborns and the risk of blood transfusion complications, it is necessary to pay more attention following or after to blood transfusion. The aim of this study was to evaluate the frequency and risk factors of blood transfusions in hospitalized neonates. Methods: A cross-sectional study was performed on 1106 infants admitted in the neonatal intensive care unit (NICU of Mustafa Khomeini University Hospital, Tehran, Iran, from spring 2009 to 2012. Frequency and the reason for of blood components transfusion including fresh frozen plasma, platelets, whole blood, packed red blood cells, cryoprecipitate and relationship with gestational age, sex, birth weight, Apgar score, duration of hospitalization, use of mechanical ventilation were assessed. Statistical analysis was performed with SPSS statistical software, version 16 (IBM, Armonk, NY, USA and statistical test, chi-square test, independent t-test and analysis of variance (ANOVA. Results: Among 1106 infants admitted to the neonatal intensive care unit, 221 infants (%19.98 received blood products. 82 of all (37% were female and 139 (%63 were female. 113 (51% of neonate were preterm and 108 (48% were term. From 361 times of blood transfusions, 121 infant (54.75% received at least one blood product. The frequency of blood transfusion was between 39 and 1 times, with an average of 3.65 times per infant. Frequency of fresh frozen plasma infusion was 173 (47.9%, packed cell 122 (33%, platelet 32 (8.8%, cryoprecipitate 20 (5.1% and whole blood 3 unit (0.83%. The most common causes for fresh frozen plasma transfusion was replacement therapy 140 (80%, for packed cell, to correct symptomatic anemia 68 (55.6%, for platelet transfusions was to prevent bleeding in  neonates with thrombocytopenia 20 (62.5% and cryoprecipitate for bleeding caused by DIC in 18 infant (90%. There was significant relation between frequency of

  12. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...

  13. Infrared tomography for diagnostic imaging of port wine stain blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The objective of this work is the development of Infrared Tomography (IRT) for detecting and characterizing subsurface chromophores in human skin. Characterization of cutaneous chromophores is crucial for advances in the laser treatment of pigmented lesions (e.g., port wine stain birthmarks and tatoos). Infrared tomography (IRT) uses a fast infrared focal plane array (IR-FPA) to detect temperature rises in a substrate induced by pulsed radiation. A pulsed laser is used to produce transient heating of an object. The temperature rise, due to the optical absorption of the pulsed laser light, creates an increase in infrared emission which is measured by the IR-FPA. Although the application of IRT to image subsurface cracks due to metal fatigue is a topic of great interest in the aircraft industry, the application to image subsurface chromophores in biological materials is novel. We present an image recovery method based on a constrained conjugate gradient algorithm that has obtained the first ever high quality images of port wine blood vessels.

  14. Time-resolved blood flow measurement in the in vivo mouse model by optical frequency domain imaging

    Science.gov (United States)

    Walther, Julia; Mueller, Gregor; Meissner, Sven; Cimalla, Peter; Homann, Hanno; Morawietz, Henning; Koch, Edmund

    2009-07-01

    In this study, we demonstrate that phase-resolved Doppler optical frequency domain imaging (OFDI) is very suitable to quantify the pulsatile blood flow within a vasodynamic measurement in the in vivo mouse model. For this, an OFDI-system with a read-out rate of 20 kHz and a center wavelength of 1320 nm has been used to image the time-resolved murine blood flow in 300 μμm vessels. Because OFDI is less sensitive to fringe washout due to axial sample motion, it is applied to analyze the blood flow velocities and the vascular dynamics in six-week-old C57BL/6 mice compared to one of the LDLR knockout strain kept under sedentary conditions or with access to voluntary wheel running. We have shown that the systolic as well as the diastolic phase of the pulsatile arterial blood flow can be well identified at each vasodynamic state. Furthermore, the changes of the flow velocities after vasoconstriction and -dilation were presented and interpreted in the entire physiological context. With this, the combined measurement of time-resolved blood flow and vessel diameter provides the basis to analyze the vascular function and its influence on the blood flow of small arteries of different mouse strains in response to different life styles.

  15. Automatic Recognition of Acute Myelogenous Leukemia in Blood Microscopic Images Using K-means Clustering and Support Vector Machine.

    Science.gov (United States)

    Kazemi, Fatemeh; Najafabadi, Tooraj Abbasian; Araabi, Babak Nadjar

    2016-01-01

    Acute myelogenous leukemia (AML) is a subtype of acute leukemia, which is characterized by the accumulation of myeloid blasts in the bone marrow. Careful microscopic examination of stained blood smear or bone marrow aspirate is still the most significant diagnostic methodology for initial AML screening and considered as the first step toward diagnosis. It is time-consuming and due to the elusive nature of the signs and symptoms of AML; wrong diagnosis may occur by pathologists. Therefore, the need for automation of leukemia detection has arisen. In this paper, an automatic technique for identification and detection of AML and its prevalent subtypes, i.e., M2-M5 is presented. At first, microscopic images are acquired from blood smears of patients with AML and normal cases. After applying image preprocessing, color segmentation strategy is applied for segmenting white blood cells from other blood components and then discriminative features, i.e., irregularity, nucleus-cytoplasm ratio, Hausdorff dimension, shape, color, and texture features are extracted from the entire nucleus in the whole images containing multiple nuclei. Images are classified to cancerous and noncancerous images by binary support vector machine (SVM) classifier with 10-fold cross validation technique. Classifier performance is evaluated by three parameters, i.e., sensitivity, specificity, and accuracy. Cancerous images are also classified into their prevalent subtypes by multi-SVM classifier. The results show that the proposed algorithm has achieved an acceptable performance for diagnosis of AML and its common subtypes. Therefore, it can be used as an assistant diagnostic tool for pathologists.

  16. Dynamic Glucose Enhanced (DGE) MRI for Combined Imaging of Blood Brain Barrier Break Down and Increased Blood Volume in Brain Cancer

    Science.gov (United States)

    Xu, Xiang; Chan, Kannie WY; Knutsson, Linda; Artemov, Dmitri; Xu, Jiadi; Liu, Guanshu; Kato, Yoshinori; Lal, Bachchu; Laterra, John; McMahon, Michael T.; van Zijl, Peter C.M.

    2015-01-01

    Purpose Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown. Methods Mice were inoculated orthotopically with human U87-EGFRvIII glioma cells. Time-resolved glucose signal changes were detected using chemical exchange saturation transfer (glucoCEST) MRI. Dynamic glucose enhanced (DGE) MRI was used to measure tissue response to an intravenous bolus of d-glucose. Results DGE images of mouse brains bearing human glioma showed two times higher and persistent changes in tumor compared to contralateral brain. Area-under-curve (AUC) analysis of DGE delineated blood vessels and tumor and had contrast comparable to the AUC determined using dynamic contrast enhanced (DCE) MRI with GdDTPA, both showing a significantly higher AUC in tumor than in brain (pblood volume and permeability with respect to normal brain. We expect DGE will provide a low-risk and less expensive alternative to DCE MRI for imaging cancer in vulnerable populations, such as children and patients with renal impairment. PMID:26404120

  17. Label-free in vivo optical micro-angiography imaging of cerebral capillary blood flow within meninges and cortex in mice with the skull left intact

    Science.gov (United States)

    Jia, Yali; Wang, Ruikang K.

    2011-03-01

    Abnormal microcirculation within meninges is common in many neurological diseases. There is a need for an imaging method that is capable of visualizing functional meningeal microcirculations alone, preferably decoupled from the cortical blood flow. Optical microangiography (OMAG) is a recently developed label-free imaging method capable of producing 3D images of dynamic blood perfusion within micro-circulatory tissue beds at an imaging depth up to ~2 mm, with an unprecedented imaging sensitivity to the blood flow at ~4 μm/s. In this study, we demonstrate the utility of ultra-high sensitive OMAG in imaging the detailed blood flow distributions, at a capillary level resolution, within meninges and cortex in mice with the cranium left intact. The results indicate that OMAG can be a valuable tool for the study of meningeal circulations.

  18. Multispectral photoacoustic characterization of ICG and porcine blood using an LED-based photoacoustic imaging system

    Science.gov (United States)

    Shigeta, Yusuke; Sato, Naoto; Kuniyil Ajith Singh, Mithun; Agano, Toshitaka

    2018-02-01

    Photoacoustic imaging is a hybrid biomedical imaging modality that has emerged over the last decade. In photoacoustic imaging, pulsed-light absorbed by the target emits ultrasound that can be detected using a conventional ultrasound array. This ultrasound data can be used to reconstruct the location and spatial details of the intrinsic/extrinsic light absorbers in the tissue. Recently we reported on the development of a multi-wavelength high frame-rate LED-based photoacoustic/ultrasound imaging system (AcousticX). In this work, we photoacoustically characterize the absorption spectrum of ICG and porcine blood using LED arrays with multiple wavelengths (405, 420, 470, 520, 620, 660, 690, 750, 810, 850, 925, 980 nm). Measurements were performed in a simple reflection mode configuration in which LED arrays where fixed on both sides of the linear array ultrasound probe. Phantom used consisted of micro-test tubes filled with ICG and porcine blood, which were placed in a tank filled with water. The photoacoustic spectrum obtained from our measurements matches well with the reference absorption spectrum. These results demonstrate the potential capability of our system in performing clinical/pre-clinical multispectral photoacoustic imaging.

  19. Regional Myocardial Blood Volume and Flow: First-Pass MR Imaging with Polylysine-Gd-DTPA

    Science.gov (United States)

    Wilke, Norbert; Kroll, Keith; Merkle, Hellmut; Wang, Ying; Ishibashi, Yukata; Xu, Ya; Zhang, Jiani; Jerosch-Herold, Michael; Mühler, Andreas; Stillman, Arthur E.; Bassingthwaighte, James B.; Bache, Robert; Ugurbil, Kamil

    2010-01-01

    The authors investigated the utility of an intravascular magnetic resonance (MR) contrast agent, poly-L-lysine-gadolinium diethylenetriaminepentaacetic acid (DTPA), for differentiating acutely ischemic from normally perfused myocardium with first-pass MR imaging. Hypoperfused regions, identified with microspheres, on the first-pass images displayed significantly decreased signal intensities compared with normally perfused myocardium (P < .0007). Estimates of regional myocardial blood content, obtained by measuring the ratio of areas under the signal intensity-versus-time curves in tissue regions and the left ventricular chamber, averaged 0.12 mL/g ± 0.04 (n = 35), compared with a value of 0.11 mL/g ± 0.05 measured with radiolabeled albumin in the same tissue regions. To obtain MR estimates of regional myocardial blood flow, in situ calibration curves were used to transform first-pass intensity-time curves into content-time curves for analysis with a multiple-pathway, axially distributed model. Flow estimates, obtained by automated parameter optimization, averaged 1.2 mL/min/g ± 0.5 [n = 29), compared with 1.3 mL/min/g ± 0.3 obtained with tracer microspheres in the same tissue specimens at the same time. The results represent a combination of T1-weighted first-pass imaging, intravascular relaxation agents, and a spatially distributed perfusion model to obtain absolute regional myocardial blood flow and volume. PMID:7766986

  20. Using wavelet denoising and mathematical morphology in the segmentation technique applied to blood cells images

    OpenAIRE

    Boix García, Macarena; Cantó Colomina, Begoña

    2013-01-01

    Accurate image segmentation is used in medical diagnosis since this technique is a noninvasive pre-processing step for biomedical treatment. In this work we present an efficient segmentation method for medical image analysis. In particular, with this method blood cells can be segmented. For that, we combine the wavelet transform with morphological operations. Moreover, the wavelet thresholding technique is used to eliminate the noise and prepare the image for suitable segmentation. In wavelet...

  1. Value of lateral blood pool imaging in patients with suspected stress fractures of the tibia.

    Science.gov (United States)

    Mohan, Hosahalli K; Clarke, Susan E M; Centenara, Martin; Lucarelli, Amanda; Baron, Daniel; Fogelman, Ignac

    2011-03-01

    To critically evaluate the use of lateral blood pool imaging in athletes with lower limb pain and with a clinical suspicion of stress fracture. Two experienced nuclear medicine physicians evaluated 3-phase bone scans using 99mTc-methylene diphosphonate performed in 50 consecutive patients referred from a specialist sports injury clinic for suspected tibial stress fracture. The vascularity to the tibia as seen on the blood pool (second phase) images in the anterior/posterior views was compared with the lateral/medial view assessments. Stress fractures were presumed to be present when on the delayed images (third phase) there was a focal or fusiform area of increased tracer uptake involving the tibial cortex. Shin splints which are a recognized cause of lower limb pain in athletes mimicking stress fracture were diagnosed if increased tracer uptake was seen extending along the posterior tibial surface with no significant focal or fusiform area of uptake within this. Inter-reviewer agreement for the assessment of vascularity was also assessed using Cohen's Kappa scores. Twenty-four stress fractures in 24 patients and 66 shin splints in 40 patients were diagnosed. In 18 patients stress fracture and shin splints coexisted. In 10 patients no tibial pathology was identified. Of the 24 patients diagnosed with stress fractures, lateral/medial blood pool imaging was superior in the assessment of blood pool activity (P tibial stress fractures, lateral views of the tibia provide the optimal method for evaluation of vascularity. Prospective studies with quantitative or semi-quantitative assessment of skeletal vascularity could provide supplementary information relating to the pathophysiology of stress fractures, for example, the time scale of vascular changes after a tibial stress fracture, and potentially could have clinical relevance as to the assessment of the severity of stress fractures and their prognosis.

  2. Red blood cell populations and membrane levels of peroxiredoxin 2 as candidate biomarkers to reveal blood doping.

    Science.gov (United States)

    Marrocco, Cristina; Pallotta, Valeria; D'alessandro, Angelo; Alves, Gilda; Zolla, Lello

    2012-05-01

    Blood doping represents one main trend in doping strategies. Blood doping refers to the practice of boosting the number of red blood cells (RBCs) in the bloodstream in order to enhance athletic performance, by means of blood transfusions, administration of erythropoiesis-stimulating substances, blood substitutes, natural or artificial altitude facilities, and innovative gene therapies. While detection of recombinant EPO and homologous transfusion is already feasible through electrophoretic, mass spectrometry or flow cytometry-based approaches, no method is currently available to tackle doping strategies relying on autologous transfusions. We exploited an in vitro model of autologous transfusion through a 1:10 dilution of concentrated RBCs after 30 days of storage upon appropriate dilution in freshly withdrawn RBCs from the same donor. Western blot towards membrane Prdx2 and Percoll density gradients were exploited to assess their suitability as biomarkers of transfusion. Membrane Prdx2 was visible in day 30 samples albeit not in day 0, while it was still visible in the 1:10 dilution of day 30 in day 0 RBCs. Cell gradients also highlighted changes in the profile of the RBC subpopulations upon dilution of stored RBCs in the fresh ones. From this preliminary in vitro investigation it emerges that Prdx2 and RBC populations might be further tested as candidate biomarkers of blood doping through autologous transfusion, though it is yet to be assessed whether the kinetics in vivo of Prdx2 exposure in the membrane of transfused RBCs will endow a sufficient time-window to allow reliable anti-doping testing.

  3. Imaging local cerebral blood flow by xenon-enhanced computed tomography - technical optimization procedures

    International Nuclear Information System (INIS)

    Meyer, J.S.; Shinohara, T.; Imai, A.; Kobari, M.; Solomon, E.

    1988-01-01

    Methods are described for non-invasive, computer-assisted serial scanning throughout the human brain during eight minutes of inhalation of 27%-30% xenon gas in order to measure local cerebral blood flow (LCBF). Optimized xenon-enhanced computed tomography (XeCT) was achieved by 5-second scanning at one-minute intervals utilizing a state-of-the-art CT scanner and rapid delivery of xenon gas via a face mask. Values for local brain-blood partition coefficients (Lλ) measured in vivo were utilized to calculate LCBF values. Previous methods assumed Lλ values to be normal, introducing the risk of systematic errors, because Lλ values differ throughout normal brain and may be altered by disease. Color-coded maps of Lλ and LCBF values were formatted directly onto CT images for exact correlation of function with anatomic and pathologic observations (spatial resolution: 26.5 cubic mm). Results were compared among eight normal volunteers, aged between 50 and 88 years. Mean cortical gray matter blood flow was 46.3 ± 7.7, for subcortical gray matter it was 50.3 ± 13.2 and for white matter it was 18.8 ± 3.2. Modern CT scanners provide stability, improved signal to noise ratio and minimal radiation scatter. Combining these advantages with rapid xenon saturation of the blood provides correlations of Lλ and LCBF with images of normal and abnormal brain in a safe, useful and non-invasive manner. (orig.)

  4. Automated image processing method for the diagnosis and classification of malaria on thin blood smears.

    Science.gov (United States)

    Ross, Nicholas E; Pritchard, Charles J; Rubin, David M; Dusé, Adriano G

    2006-05-01

    Malaria is a serious global health problem, and rapid, accurate diagnosis is required to control the disease. An image processing algorithm to automate the diagnosis of malaria on thin blood smears is developed. The image classification system is designed to positively identify malaria parasites present in thin blood smears, and differentiate the species of malaria. Images are acquired using a charge-coupled device camera connected to a light microscope. Morphological and novel threshold selection techniques are used to identify erythrocytes (red blood cells) and possible parasites present on microscopic slides. Image features based on colour, texture and the geometry of the cells and parasites are generated, as well as features that make use of a priori knowledge of the classification problem and mimic features used by human technicians. A two-stage tree classifier using backpropogation feedforward neural networks distinguishes between true and false positives, and then diagnoses the species (Plasmodium falciparum, P. vivax, P. ovale or P. malariae) of the infection. Malaria samples obtained from the Department of Clinical Microbiology and Infectious Diseases at the University of the Witwatersrand Medical School are used for training and testing of the system. Infected erythrocytes are positively identified with a sensitivity of 85% and a positive predictive value (PPV) of 81%, which makes the method highly sensitive at diagnosing a complete sample provided many views are analysed. Species were correctly determined for 11 out of 15 samples.

  5. The secondary biogenic radiation of gamma-irradiated human blood

    International Nuclear Information System (INIS)

    Kuzin, A.M.; Surkenova, G.N.; Budagovskij, A.V.; Gudi, G.A.

    1997-01-01

    The sample of blood freshly taken from healthy men were gamma-irradiated with a dose of 10 Gy. It was shown that after the treatment the blood gained the capacity to emit secondary biogenic radiation. Emission lasted for some hours, passed through quartz-glass curette and was revealed by stimulating influence on biological detector (sprouting seeds)

  6. Simultaneous imaging of cerebral partial pressure of oxygen and blood flow during functional activation and cortical spreading depression

    Science.gov (United States)

    Sakadžić, Sava; Yuan, Shuai; Dilekoz, Ergin; Ruvinskaya, Svetlana; Vinogradov, Sergei A.; Ayata, Cenk; Boas, David A.

    2009-01-01

    We developed a novel imaging technique that provides real-time two-dimensional maps of the absolute partial pressure of oxygen and relative cerebral blood flow in rats by combining phosphorescence lifetime imaging with laser speckle contrast imaging. Direct measurement of blood oxygenation based on phosphorescence lifetime is not significantly affected by changes in the optical parameters of the tissue during the experiment. The potential of the system as a novel tool for quantitative analysis of the dynamic delivery of oxygen to support brain metabolism was demonstrated in rats by imaging cortical responses to forepaw stimulation and the propagation of cortical spreading depression waves. This new instrument will enable further study of neurovascular coupling in normal and diseased brain. PMID:19340106

  7. Highly sensitive transient absorption imaging of graphene and graphene oxide in living cells and circulating blood

    OpenAIRE

    Junjie Li; Weixia Zhang; Ting-Fung Chung; Mikhail N. Slipchenko; Yong P. Chen; Ji-Xin Cheng; Chen Yang

    2015-01-01

    We report a transient absorption (TA) imaging method for fast visualization and quantitative layer analysis of graphene and GO. Forward and backward imaging of graphene on various substrates under ambient condition was imaged with a speed of 2??s per pixel. The TA intensity linearly increased with the layer number of graphene. Real-time TA imaging of GO in vitro with capability of quantitative analysis of intracellular concentration and ex vivo in circulating blood were demonstrated. These re...

  8. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...... in cerebral hemodynamics than noncontrast-enhanced imaging. The results of the deconvolution analysis suggested that perfusion calculation by conventional tracer kinetic methods may be impracticable because of nonlinear effects in contrast-enhanced MR imaging....

  9. Contrasting effects of fresh and fermented kimchi consumption on gut microbiota composition and gene expression related to metabolic syndrome in obese Korean women.

    Science.gov (United States)

    Han, Kyungsun; Bose, Shambhunath; Wang, Jing-hua; Kim, Bong-Soo; Kim, Mi Jeong; Kim, Eun-Jung; Kim, Hojun

    2015-05-01

    Accumulating evidence suggests relationship of compositional changes of gut microbiota with onset of metabolic disorders and obesity. Kimchi, a traditional Korean side dish, is known for its beneficial impact on metabolic parameters and anti-obesity effects. The current study was designed to evaluate the association between gut microbiota and human genome after kimchi intervention in an effort to understand the molecular mechanism(s) underlying the antiobesity impact of kimchi. Twenty-four obese women were randomly assigned to either fresh or fermented kimchi group for eight weeks of kimchi intervention. Pyrosequencing of fecal microbiota and microarray analyses of blood samples revealed that fresh and fermented kimchi interventions exerted differential effects on the obesity-related clinical parameters. Correlations of these effects with changes in blood gene expression and gut microbial population were more evident in the fermented kimchi group than the fresh kimchi group. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Lysis of fresh human solid tumors by autologous lymphocytes activated in vitro with lectins

    International Nuclear Information System (INIS)

    Mazumder, A.; Grimm, E.A.; Zhang, H.Z.; Rosenberg, S.A.

    1982-01-01

    Human peripheral blood lymphocytes (PBL), obtained from patients with a variety of cancers, were incubated in vitro with phytohemagglutinin, concanavalin A, and crude or lectin-free T-cell growth factors. The lectin-activated PBL of nine patients were capable of lysing fresh autologous tumor during a 4-hr 51Cr release assay. Multiple metastases from the same patient were equivalently lysed by these activated autologous PBL. No lysis of fresh PBL or lectin-induced lymphoblast cell targets was seen, although tumor, PBL, and lymphoblast cells were shown to be equally lysable using allosensitized cells. The activated cells could be expanded without loss of cytotoxicity in crude or lectin-free T-cell growth factors. The generation of cells lytic to fresh autologous tumor was dependent on the presence of adherent cells, although the lytic cell itself was not adherent. Proliferation was not involved in the induction of lytic cells since equal lysis was induced in irradiated and nonirradiated lymphocytes. Lectin was not required in the lytic assay, and the addition of alpha-methyl-D-mannoside to concanavalin A-activated lymphoid cells did not increase the lysis of fresh tumor cells. Activation by lectin for 3 days appears to be an efficient and convenient method for generating human cells lytic to fresh autologous tumor. These lytic cells may be of value for studies of the cell-mediated lysis of human tumor and possibly for tumor immunotherapy as well

  11. Spatial Temporal Image Correlation Spectroscopy (STICS) for Flow Analysis with Application for Blood Flow Mapping

    International Nuclear Information System (INIS)

    Rossow, Molly; Gratton, Enrico; Mantulin, William M.

    2009-01-01

    It is important for surgeons to be able to measure blood flow in exposed arterioles during surgery. We report our progress in the development of an optical technique that will measure blood flow in surgically exposed blood vessels and enable previously difficult measurements. By monitoring optical fluctuations, the optical technique, based on Spatial Temporal Image Correlation (STICS), will directly measure the velocity of micron-scale particles--such as red blood cells. It will complement existing technology and provide qualitative measurements that were not previously possible. It relies on the concept that blood, when viewed on a small enough scale, is an inhomogeneous substance. Individual blood cells passing between a near-infrared light source and a detector will cause fluctuations in the transmitted optical signal. The speed, direction, and flow pattern of blood cells can be determined from these optical fluctuations. We present a series of computer simulations and experiments on phantom and animal systems to test this technique's ability to map complex flow patterns.

  12. Cardiac cine MRI: Comparison of 1.5 T, non-enhanced 3.0 T and blood pool enhanced 3.0 T imaging

    International Nuclear Information System (INIS)

    Gerretsen, S.C.; Versluis, B.; Bekkers, S.C.A.M.; Leiner, T.

    2008-01-01

    Introduction: Cardiac cine imaging using balanced steady state free precession sequences (bSSFP) suffers from artefacts at 3.0 T. We compared bSSFP cardiac cine imaging at 1.5 T with gradient echo imaging at 3.0 T with and without a blood pool contrast agent. Materials and methods: Eleven patients referred for cardiac cine imaging underwent imaging at 1.5 T and 3.0 T. At 3.0 T images were acquired before and after administration of 0.03 mmol/kg gadofosveset. Blood pool signal-to-noise ratio (SNR), temporal variations in SNR, ejection fraction and myocardial mass were compared. Subjective image quality was scored on a four-point scale. Results: Blood pool SNR increased with more than 75% at 3.0 T compared to 1.5 T (p < 0.001); after contrast administration at 3.0 T SNR increased with 139% (p < 0.001). However, variations in blood pool SNR at 3.0 T were nearly three times as high versus those at 1.5 T in the absence of contrast medium (p < 0.001); after contrast administration this was reduced to approximately a factor 1.4 (p = 0.21). Saturation artefacts led to significant overestimation of ejection fraction in the absence of contrast administration (1.5 T: 44.7 ± 3.1 vs. 3.0 T: 50.7 ± 4.2 [p = 0.04] vs. 3.0 T post contrast: 43.4 ± 2.9 [p = 0.55]). Subjective image quality was highest for 1.5 T (2.8 ± 0.3), and lowest for non-enhanced 3.0 T (1.7 ± 0.6; p = 0.006). Conclusions: GRE cardiac cine imaging at 3.0 T after injection of the blood pool agent gadofosveset leads to improved objective and subjective cardiac cine image quality at 3.0 T and to the same conclusions regarding cardiac ejection fraction compared to bSSFP imaging at 1.5 T

  13. Packed red blood cells are an abundant and proximate potential source of nitric oxide synthase inhibition.

    Directory of Open Access Journals (Sweden)

    Charles F Zwemer

    Full Text Available We determined, for packed red blood cells (PRBC and fresh frozen plasma, the maximum content, and ability to release the endogenous nitric oxide synthase (NOS inhibitors asymmetric dimethylarginine (ADMA and monomethylarginine (LNMMA.ADMA and LNMMA are near equipotent NOS inhibitors forming blood's total NOS inhibitory content. The balance between removal from, and addition to plasma determines their free concentrations. Removal from plasma is by well-characterized specific hydrolases while formation is restricted to posttranslational protein methylation. When released into plasma they can readily enter endothelial cells and inhibit NOS. Fresh rat and human whole blood contain substantial protein incorporated ADMA however; the maximum content of ADMA and LNMMA in PRBC and fresh frozen plasma has not been determined.We measured total (free and protein incorporated ADMA and LNMMA content in PRBCs and fresh frozen plasma, as well as their incubation induced release, using HPLC with fluorescence detection. We tested the hypothesis that PRBC and fresh frozen plasma contain substantial inhibitory methylarginines that can be released chemically by complete in vitro acid hydrolysis or physiologically at 37°C by enzymatic blood proteolysis.In vitro strong-acid-hydrolysis revealed a large PRBC reservoir of ADMA (54.5 ± 9.7 µM and LNMMA (58.9 ± 28.9 μM that persisted over 42-d at 6° or -80°C. In vitro 5h incubation at 37°C nearly doubled free ADMA and LNMMNA concentration from PRBCs while no change was detected in fresh frozen plasma.The compelling physiological ramifications are that regardless of storage age, 1 PRBCs can rapidly release pathologically relevant quantities of ADMA and LNMMA when incubated and 2 PRBCs have a protein-incorporated inhibitory methylarginines reservoir 100 times that of normal free inhibitory methylarginines in blood and thus could represent a clinically relevant and proximate risk for iatrogenic NOS inhibition upon

  14. Acute Blood Loss During Burn and Soft Tissue Excisions: An Observational Study of Blood Product Resuscitation Practices and Focused Review

    Science.gov (United States)

    2015-06-24

    prospective observational study. Number, component type , volume, and age of the blood products transfused were recorded during burn excision/grafting or soft...tissue debridement . Component bags (packed red blood cells, fresh frozen plasma, platelets, and cryoprecipitate) were collected, and the remaining...collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 24 JUN 2015 2. REPORT TYPE N/A 3. DATES

  15. Antimicrobial packaging for fresh-cut fruits

    Science.gov (United States)

    Fresh-cut fruits are minimally processed produce which are consumed directly at their fresh stage without any further kill step. Microbiological quality and safety are major challenges to fresh-cut fruits. Antimicrobial packaging is one of the innovative food packaging systems that is able to kill o...

  16. Multimodal in vivo blood flow sensing combining particle image velocimetry and optical tweezers-based blood steering

    Science.gov (United States)

    Meissner, Robert; Sugden, Wade W.; Siekmann, Arndt F.; Denz, Cornelia

    2018-02-01

    All higher developed organisms contain complex hierarchical networks of arteries, veins and capillaries. These constitute the cardiovascular system responsible for supplying nutrients, gas and waste exchange. Diseases related to the cardiovascular system are among the main causes for death worldwide. In order to understand the processes leading to arteriovenous malformation, we studied hereditary hemorrhagic telangiectasia (HHT), which has a prevalence of 1:5000 worldwide and causes internal bleeding. In zebrafish, HHT is induced by mutation of the endoglin gene involved in HHT and observed to reduce red blood cell (RBC) flow to intersegmental vessels (ISVs) in the tail due to malformations of the dorsal aorta (DA) and posterior cardinal vein (PCV). However, these capillaries are still functional. Changes in the blood flow pattern are observed from in vivo data from zebrafish embryos through particle image velocimetry (PIV). Wall shear rates (WSRs) and blood flow velocities are obtained non-invasively with millisecond resolution. We observe significant increases of blood flow velocity in the DA for endoglin-deficient zebrafish embryos (mutants) at 3 days post fertilization. In the PCV, this increase is even more pronounced. We identified an increased similarity between the DA and the PCV of mutant fish compared to siblings, i.e., unaffected fish. To counteract the reduced RBC flow to ISVs we implement optical tweezers (OT). RBCs are steered into previously unperfused ISVs showing a significant increase of RBC count per minute. We discuss limitations with respect to biocompatibility of optical tweezers in vivo and determination of in vivo wall shear stress (WSS) connected to normal and endoglin-deficicent zebrafish embryos.

  17. Evaluation of the quality of blood components obtained after automated separation of whole blood by a new multiunit processor

    DEFF Research Database (Denmark)

    Lagerberg, Johan W; Salado-Jimena, Jose A; Löf, Helena

    2013-01-01

    The Reveos system (Terumo BCT) is a fully automated device able to process four whole blood (WB) units simultaneously into a plasma unit, a red blood cell (RBC) unit, and an interim platelet (PLT) unit (IPU). Multiple IPUs can be pooled to form a transfusable PLT product. The aim of our study...... was to evaluate the quality of components made with the Reveos system from either fresh (2-8 hr) or overnight-held WB....

  18. Perception of body image of adolescents and of their parents in relation to the nutritional status and blood pressure.

    Science.gov (United States)

    Silveira Vieira, Raquel; Dal Bosco, Simone Morelo; Grave, Magali Trezinha Quevedo; Adami, Fernanda Scherer

    2015-04-01

    The perception of body image of adolescents is an instrument for nutritional assessment to health conditions. To verify the body image perception of adolescents and their parents in relation to nutritional status and blood pressure levels. Population-based study, and cross-sectional model, conducted with parents and adolescents aged 10-19 years old, in rural and urban zones in public schools. There was applied the Scale silhouettes for parents about the perception of the described body image and a question about the concern of the nutritional status of their children. There were verified the blood pressure, weight, height and waist circumference, the BMI (kg/m²) calculation of the adolescents, and the self-perceived body image. The data was expressed as average ± standard deviation and percentages. The sample consisted of 914 adolescents with a mean age of 13.12 ± 2.17 years, 56.8% female and 68.9% were eutrophic. As for blood pressure levels, 17.6% were classified in pre-hypertensive, 18.8% in stage 1 hypertension and 6% in stage 2. About the self-perception, 68% considered themselves being eutrophic and 64.75% of the parents classified their children as eutrophic. There was observed a direct and significant correlation among the body mass index, waist circumference, weight, systemic and diastolic blood pressure with the self-perception of the adolescents and the body image perceptions of the parents (ppressure, waist circumference and body image perceptions of the adolescents and their respective parents. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  19. What is a Fresh Scent in Perfumery? Perceptual Freshness is Correlated with Substantivity

    Directory of Open Access Journals (Sweden)

    Manuel Zarzo

    2012-12-01

    Full Text Available Perfumes are manufactured by mixing odorous materials with different volatilities. The parameter that measures the lasting property of a material when applied on the skin is called substantivity or tenacity. It is well known by perfumers that citrus and green notes are perceived as fresh and they tend to evaporate quickly, while odors most dissimilar to ‘fresh’ (e.g., oriental, powdery, erogenic and animalic scents are tenacious. However, studies aimed at quantifying the relationship between fresh odor quality and substantivity have not received much attention. In this work, perceptual olfactory ratings on a fresh scale, estimated in a previous study, were compared with substantivity parameters and antierogenic ratings from the literature. It was found that the correlation between fresh odor character and odorant substantivity is quite strong (r = −0.85. ‘Fresh’ is sometimes interpreted in perfumery as ‘cool’ and the opposite of ‘warm’. This association suggests that odor freshness might be somehow related to temperature. Assuming that odor perception space was shaped throughout evolution in temperate climates, results reported here are consistent with the hypothesis that ‘fresh’ evokes scents typically encountered in the cool season, while ‘warm’ would be evoked by odors found in nature during summer. This hypothesis is rather simplistic but it may provide a new insight to better understand the perceptual space of scents.

  20. Image-based model of the spectrin cytoskeleton for red blood cell simulation.

    Science.gov (United States)

    Fai, Thomas G; Leo-Macias, Alejandra; Stokes, David L; Peskin, Charles S

    2017-10-01

    We simulate deformable red blood cells in the microcirculation using the immersed boundary method with a cytoskeletal model that incorporates structural details revealed by tomographic images. The elasticity of red blood cells is known to be supplied by both their lipid bilayer membranes, which resist bending and local changes in area, and their cytoskeletons, which resist in-plane shear. The cytoskeleton consists of spectrin tetramers that are tethered to the lipid bilayer by ankyrin and by actin-based junctional complexes. We model the cytoskeleton as a random geometric graph, with nodes corresponding to junctional complexes and with edges corresponding to spectrin tetramers such that the edge lengths are given by the end-to-end distances between nodes. The statistical properties of this graph are based on distributions gathered from three-dimensional tomographic images of the cytoskeleton by a segmentation algorithm. We show that the elastic response of our model cytoskeleton, in which the spectrin polymers are treated as entropic springs, is in good agreement with the experimentally measured shear modulus. By simulating red blood cells in flow with the immersed boundary method, we compare this discrete cytoskeletal model to an existing continuum model and predict the extent to which dynamic spectrin network connectivity can protect against failure in the case of a red cell subjected to an applied strain. The methods presented here could form the basis of disease- and patient-specific computational studies of hereditary diseases affecting the red cell cytoskeleton.

  1. Diabetes and blood pressure (image)

    Science.gov (United States)

    People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ... People with diabetes have a higher risk for heart attacks and strokes. Your doctor or nurse should check your blood pressure ...

  2. Performance evaluation of photoacoustic oximetry imaging systems using a dynamic blood flow phantom with tunable oxygen saturation

    Science.gov (United States)

    Vogt, William C.; Zhou, Xuewen; Andriani, Rudy; Wear, Keith A.; Garra, Brian S.; Pfefer, Joshua

    2018-02-01

    Photoacoustic Imaging (PAI) is an emerging technology with strong potential for broad clinical applications from breast cancer detection to cerebral monitoring due to its ability to compute maps of blood oxygen saturation (SO2) distribution in deep tissues using multispectral imaging. However, no well-validated consensus test methods currently exist for evaluating oximetry-specific performance characteristics of PAI devices. We have developed a phantombased flow system capable of rapid SO2 adjustment to serve as a test bed for elucidation of factors impacting SO2 measurement and quantitative characterization of device performance. The flow system is comprised of a peristaltic pump, membrane oxygenator, oxygen and nitrogen gas, and in-line oxygen, pH, and temperature sensors that enable real-time estimation of SO2 reference values. Bovine blood was delivered through breast-relevant tissue phantoms containing vessel-mimicking fluid channels, which were imaged using a custom multispectral PAI system. Blood was periodically drawn for SO2 measurement in a clinical-grade CO-oximeter. We used this flow phantom system to evaluate the impact of device parameters (e.g.,wavelength-dependent fluence corrections) and tissue parameters (e.g. fluid channel depth, blood SO2, spectral coloring artifacts) on oximetry measurement accuracy. Results elucidated key challenges in PAI oximetry and device design trade-offs, which subsequently allowed for optimization of system performance. This approach provides a robust benchtop test platform that can support PAI oximetry device optimization, performance validation, and clinical translation, and may inform future development of consensus test methods for performance assessment of photoacoustic oximetry imaging systems.

  3. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  4. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  5. Fresh and preserved green fodder modify effects of urinary acidifiers on urine pH of horses.

    Science.gov (United States)

    Goren, G; Fritz, J; Dillitzer, N; Hipp, B; Kienzle, E

    2014-04-01

    Hay stabilises urine pH in horses. It is unknown whether this is an effect of structure or of chemical composition. In this study, four ponies (230-384 kg body weight [BW]) were fed six different diets with either a structure or a composition similar to hay with and without acidifiers in a cross-over experimental design in amounts to maintain body weight with the following main compounds: Fresh grass (GRASS), alfalfa hay (ALF), grass cobs (COBS), grass silage (SIL), straw (STR) or extruded straw (STRe) for 2 to 10 days. Urine pH was measured in all trials, blood pH, blood base excess and bicarbonate as well as mineral balance were determined in GRASS, ALF, STR and STRe. In the trials with straw and extruded straw, urine pH decreased significantly (STR control: 7.8 ± 0.23, acidifier: 5.2 ± 0.38) when acidifiers were added, whereas in all other diets that were based on fresh or preserved green fodder, pH did not decrease below 7. Blood pH was similarly affected by diet and acidifiers. Acidifiers had little effect on the pre-prandial blood pH, only in diet STR there was a significant reduction in relation to control. Post-prandial blood pH was significantly reduced by acidifiers in all diets. Blood bicarbonate and base excess showed corresponding effects. Faecal and renal mineral excretion and apparent mineral digestibility were not systematically affected by diet or acidifiers except for chloride. Chloride added as inorganic chloride salt had an even better apparent digestibility than chloride originating from feed. Because only green plant material stabilised acid base balance, chlorophyll and its metabolites are discussed as potential mediators of the effect of green fodder on acid base balance. Journal of Animal Physiology and Animal Nutrition © 2013 Blackwell Verlag GmbH.

  6. Study of regional cerebral blood flow SPECT imaging for sudden sensorineural deafness

    International Nuclear Information System (INIS)

    Xie Changhui; Kui Xixiao; Xiong Qibin; Wen Hui; Xie Jiabiao

    1998-01-01

    Purpose: To study the clinical value of regional cerebral blood flow (rCBF) SPECT imaging for sudden sensorineural deafness (SSD). Methods: 10 normal persons, 19 conductive deafness and 31 SSD patients were examined by rCBF SPECT imaging, and compared with X CT at the same time. All SSD patients were followed up for 6∼12 months with repeated rCBF SPECT imaging. Results: 1) The radioactivity of diseased and normal horizontal temporal gyrus ratio (T/NT) in SSD patients was the lowest among three groups (P < 0.01). 2) The sensitivity (80.6%) and accurate rate (88.3%) of rCBF SPECT imaging in SSD patients were much higher than those of CT (3.2% and 50%, P < 0.01). 3) There was a significant correlation between degree of deafness and T/NT in SSD patients. 4) Good prognosis of SSD patients with normal rCBF SPECT was found. 5) The rCBF SPECT had close concordance between rCBF SPECT imaging and clinical prognosis (84.6%). Conclusions: rCBF SPECT imaging was superior to X CT in diagnosis of SSD and played an important clinical role

  7. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Joyce T. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Robinson, Joshua D. [Ann and Robert Lurie Children' s Hospital of Chicago, Division of Pediatric Cardiology, 225 E. Chicago Ave., Box 21, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Deng, Jie [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Rigsby, Cynthia K. [Ann and Robert Lurie Children' s Hospital of Chicago, Department of Pediatrics, Chicago, IL (United States); Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Ann and Robert Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States)

    2016-12-15

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  8. Combined blood pool and extracellular contrast agents for pediatric and young adult cardiovascular magnetic resonance imaging

    International Nuclear Information System (INIS)

    Johnson, Joyce T.; Robinson, Joshua D.; Deng, Jie; Rigsby, Cynthia K.

    2016-01-01

    A comprehensive cardiac magnetic resonance (cardiac MR) study including both late gadolinium enhancement (LGE) and MR angiography may be indicated for patients with a history of acquired or congenital heart disease. To study the novel use of an extracellular agent for assessment of LGE combined with a blood pool contrast agent for detailed MR angiography evaluation to yield a comprehensive cardiac MR study in these patients. We reviewed clinical cardiac MR studies utilizing extracellular and blood pool contrast agents and noted demographics, clinical data and adverse events. We rated LGE image quality and MR angiography image quality for each vascular segment and calculated inter-rater variability. We also quantified contrast-to-noise ratio (CNR). Thirty-three patients (mean age 13.9 ± 3 years) received an extracellular contrast agent (10 gadobenate dimeglumine, 23 gadopentetate dimeglumine) and blood pool contrast agent (33 gadofosveset trisodium). No adverse events were reported. MRI indications included Kawasaki disease (8), cardiomyopathy and coronary anatomy (15), repaired congenital heart disease (8), and other (2). Mean LGE quality was 2.6 ± 0.6 with 97% diagnostic imaging. LGE quality did not vary by type of contrast agent given (P = 0.07). Mean MR angiography quality score was 4.7 ± 0.6, with high inter-rater agreement (k = 0.6-0.8, P < 0.002). MR angiography quality did not vary by type of contrast agent used (P = 0.6). Cardiac MR studies utilizing both extracellular and blood pool contrast agents are feasible and safe and provide excellent-quality LGE and MR angiography images. The use of two contrast agents allows for a comprehensive assessment of both myocardial viability and vascular anatomy during the same exam. (orig.)

  9. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  10. Spatio-temporal analysis of blood perfusion by imaging photoplethysmography

    Science.gov (United States)

    Zaunseder, Sebastian; Trumpp, Alexander; Ernst, Hannes; Förster, Michael; Malberg, Hagen

    2018-02-01

    Imaging photoplethysmography (iPPG) has attracted much attention over the last years. The vast majority of works focuses on methods to reliably extract the heart rate from videos. Only a few works addressed iPPGs ability to exploit spatio-temporal perfusion pattern to derive further diagnostic statements. This work directs at the spatio-temporal analysis of blood perfusion from videos. We present a novel algorithm that bases on the two-dimensional representation of the blood pulsation (perfusion map). The basic idea behind the proposed algorithm consists of a pairwise estimation of time delays between photoplethysmographic signals of spatially separated regions. The probabilistic approach yields a parameter denoted as perfusion speed. We compare the perfusion speed versus two parameters, which assess the strength of blood pulsation (perfusion strength and signal to noise ratio). Preliminary results using video data with different physiological stimuli (cold pressure test, cold face test) show that all measures are influenced by those stimuli (some of them with statistical certainty). The perfusion speed turned out to be more sensitive than the other measures in some cases. However, our results also show that the intraindividual stability and interindividual comparability of all used measures remain critical points. This work proves the general feasibility of employing the perfusion speed as novel iPPG quantity. Future studies will address open points like the handling of ballistocardiographic effects and will try to deepen the understanding of the predominant physiological mechanisms and their relation to the algorithmic performance.

  11. What determines fresh fish consumption in Croatia?

    Science.gov (United States)

    Tomić, Marina; Matulić, Daniel; Jelić, Margareta

    2016-11-01

    Although fresh fish is widely available, consumption still remains below the recommended intake levels among the majority of European consumers. The economic crisis affects consumer food behaviour, therefore fresh fish is perceived as healthy but expensive food product. The aim of this study was to determine the factors influencing fresh fish consumption using an expanded Theory of Planned Behaviour (Ajzen, 1991) as a theoretical framework. The survey was conducted on a heterogeneous sample of 1151 Croatian fresh fish consumers. The study investigated the relationship between attitudes, perceived behavioural control, subjective norm, moral obligation, involvement in health, availability, intention and consumption of fresh fish. Structural Equation Modeling by Partial Least Squares was used to analyse the collected data. The results indicated that attitudes are the strongest positive predictor of the intention to consume fresh fish. Other significant predictors of the intention to consume fresh fish were perceived behavioural control, subjective norm, health involvement and moral obligation. The intention to consume fresh fish showed a strong positive correlation with behaviour. This survey provides valuable information for food marketing professionals and for the food industry in general. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Non-invasive imaging of retinal blood flow in myeloproliferative neoplasms

    DEFF Research Database (Denmark)

    Willerslev, Anne; Hansen, Mathias M; Klefter, Oliver Niels

    2017-01-01

    PURPOSE: To study the circulation in the retinal vessels in patients with blood dyscrasia due to myeloproliferative neoplasms using non-invasive retinal imaging. METHODS: Prospective consecutive case series of seven treatment-naïve patients with chronic myeloid leukaemia (n = 2), polycythemia vera...... present at baseline in patients with chronic myeloid leukaemia and were replaced by normal patterns at follow-up. Retinopathy, in the form of cotton-wool spots and retinal haemorrhages, was found at presentation in the two patients with chronic myeloid leukaemia and in one patient with polycythemia vera...

  13. Highly sensitive transient absorption imaging of graphene and graphene oxide in living cells and circulating blood.

    Science.gov (United States)

    Li, Junjie; Zhang, Weixia; Chung, Ting-Fung; Slipchenko, Mikhail N; Chen, Yong P; Cheng, Ji-Xin; Yang, Chen

    2015-07-23

    We report a transient absorption (TA) imaging method for fast visualization and quantitative layer analysis of graphene and GO. Forward and backward imaging of graphene on various substrates under ambient condition was imaged with a speed of 2 μs per pixel. The TA intensity linearly increased with the layer number of graphene. Real-time TA imaging of GO in vitro with capability of quantitative analysis of intracellular concentration and ex vivo in circulating blood were demonstrated. These results suggest that TA microscopy is a valid tool for the study of graphene based materials.

  14. Susceptibility contrast imaging of CO2-induced changes in the blood volume of the human brain

    DEFF Research Database (Denmark)

    Rostrup, Egill; Larsson, H B; Toft, P B

    1996-01-01

    PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged...... to be in accordance with results obtained by other methods. Noncontrast functional MR (fMR) imaging showed signal increases in gray matter, but also inconsistent changes in some white matter regions. CONCLUSION: In this experiment, contrast-enhanced imaging seemed to show a somewhat higher sensitivity towards changes...

  15. Platelet-rich fibrin prepared from stored whole-blood samples.

    Science.gov (United States)

    Isobe, Kazushige; Suzuki, Masashi; Watanabe, Taisuke; Kitamura, Yutaka; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki

    2017-12-01

    In regenerative therapy, self-clotted platelet concentrates, such as platelet-rich fibrin (PRF), are generally prepared on-site and are immediately used for treatment. If blood samples or prepared clots can be preserved for several days, their clinical applicability will expand. Here, we prepared PRF from stored whole-blood samples and examined their characteristics. Blood samples were collected from non-smoking, healthy male donors (aged 27-67 years, N = 6), and PRF clots were prepared immediately or after storage for 1-2 days. Fibrin fiber was examined by scanning electron microscopy. Bioactivity was evaluated by means of a bioassay system involving human periosteal cells, whereas PDGF-BB concentrations were determined by an enzyme-linked immunosorbent assay. Addition of optimal amounts of a 10% CaCl 2 solution restored the coagulative ability of whole-blood samples that contained an anticoagulant (acid citrate dextrose) and were stored for up to 2 days at ambient temperature. In PRF clots prepared from the stored whole-blood samples, the thickness and cross-links of fibrin fibers were almost identical to those of freshly prepared PRF clots. PDGF-BB concentrations in the PRF extract were significantly lower in stored whole-blood samples than in fresh samples; however, both extracts had similar stimulatory effects on periosteal-cell proliferation. Quality of PRF clots prepared from stored whole-blood samples is not reduced significantly and can be ensured for use in regenerative therapy. Therefore, the proposed method enables a more flexible treatment schedule and choice of a more suitable platelet concentrate immediately before treatment, not after blood collection.

  16. Flow imaging of the cardiovascular system using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Imai, Hitoshi; Sakakibara, Makoto; Sunami, Yuko

    1988-01-01

    Blood flow images by magnetic resonance imaging (MRI) using a 0.25 T unit were evaluated for nine normal volunteers and 108 subjects with a variety of cardiovascular abnormalities. Using the non-gated short-spin echo (SE) technique, blood flow in the cardiovascular systems was not imaged in the normal volunteers. Using end-systolic and end-diastolic SE techniques for the normal subjects, blood flow in the cardiac chambers was not clearly imaged. Blood flow in the ascending aorta and aortic arch often did not appear in the gated SE images of the normal subjects. However, blood flow in the descending aorta was often observed in the gated SE images. Blood flow imaging was demonstrated by both non-gated and gated SE techniques in regions where blood flow was relatively slow; for example, in the left atrium of mitral stenosis, in an aortic aneurysm, in a false lumen of an aortic dissection, and in the left ventricle having old myocardial infarction. Using the non-gated inversion recovery (IR) technique, no blood flow was imaged in the cardiovascular system except in the left atrium of one case with mitral stenosis. Using the non-gated short SE technique, there was good correlation between the thrombus formation and the presence of blood flow images in the left atria of 17 patients with mitral stenosis, and in the aneurysmal portions of the aorta or in the false lumens of aortic dissection of 18 patients. It was suggested that mural thrombi in such diseases were related to the relatively slow blood flow. Blood flow imaging easily distinguished stagnant blood flow from mural thrombi using non-gated short SE, end-systolic SE, and IR techniques. Thus, blood flow imaging using MRI should become an important means of evaluating the cardiovascular system. (author)

  17. Consumer's Fresh Produce Food Safety Practices: Outcomes of a Fresh Produce Safety Education Program

    Science.gov (United States)

    Scott, Amanda R.; Pope, Paul E.; Thompson, Britta M.

    2009-01-01

    The Centers for Disease Control and Prevention estimate that there are 76 million cases of foodborne disease annually. Foodborne disease is usually associated with beef, poultry, and seafood. However, there is an increasing number of foodborne disease cases related to fresh produce. Consumers may not associate fresh produce with foodborne disease…

  18. Spatial Temporal Image Correlation Spectroscopy (STICS) for Flow Analysis with Application for Blood Flow Mapping (abstract)

    Science.gov (United States)

    Rossow, Molly; Mantulin, William M.; Gratton, Enrico

    2009-04-01

    It is important for surgeons to be able to measure blood flow in exposed arterioles during surgery. We report our progress in the development of an optical technique that will measure blood flow in surgically exposed blood vessels and enable previously difficult measurements. By monitoring optical fluctuations, the optical technique, based on Spatial Temporal Image Correlation (STICS), will directly measure the velocity of micron-scale particles-such as red blood cells. It will complement existing technology and provide qualitative measurements that were not previously possible. It relies on the concept that blood, when viewed on a small enough scale, is an inhomogeneous substance. Individual blood cells passing between a near-infrared light source and a detector will cause fluctuations in the transmitted optical signal. The speed, direction, and flow pattern of blood cells can be determined from these optical fluctuations. We present a series of computer simulations and experiments on phantom and animal systems to test this technique's ability to map complex flow patterns.

  19. The image of the butcher (13th-20th): In search of respectability between corporate pride and blood concealment.

    OpenAIRE

    Leteux , Sylvain

    2015-01-01

    International audience; In most images that represent butchers in France since the Middle Ages, the animal’s blood and death are often eclipsed or softened, except for the realistic photographs of slaughterhouses in the 20th century. The will to conceal blood shows the butchers’ will to build an honourable image of themselves. This quest for respectability is obvious if you look at the ceremony clothes worn by butchers during civil and religious celebrations. In the 19th century, as the trade...

  20. Mobile phone based laser speckle contrast imager for assessment of skin blood flow

    Science.gov (United States)

    Jakovels, Dainis; Saknite, Inga; Krievina, Gita; Zaharans, Janis; Spigulis, Janis

    2014-10-01

    Assessment of skin blood flow is of interest for evaluation of skin viability as well as for reflection of the overall condition of the circulatory system. Laser Doppler perfusion imaging (LDPI) and laser speckle contrast imaging (LASCI) are optical techniques used for assessment of skin perfusion. However, these systems are still too expensive and bulky to be widely available. Implementation of such techniques as connection kits for mobile phones have a potential for primary diagnostics. In this work we demonstrate simple and low cost LASCI connection kit for mobile phone and its comparison to laser Doppler perfusion imager. Post-occlusive hyperemia and local thermal hyperemia tests are used to compare both techniques and to demonstrate the potential of LASCI device.

  1. Chagas Parasite Detection in Blood Images Using AdaBoost

    Directory of Open Access Journals (Sweden)

    Víctor Uc-Cetina

    2015-01-01

    Full Text Available The Chagas disease is a potentially life-threatening illness caused by the protozoan parasite, Trypanosoma cruzi. Visual detection of such parasite through microscopic inspection is a tedious and time-consuming task. In this paper, we provide an AdaBoost learning solution to the task of Chagas parasite detection in blood images. We give details of the algorithm and our experimental setup. With this method, we get 100% and 93.25% of sensitivity and specificity, respectively. A ROC comparison with the method most commonly used for the detection of malaria parasites based on support vector machines (SVM is also provided. Our experimental work shows mainly two things: (1 Chagas parasites can be detected automatically using machine learning methods with high accuracy and (2 AdaBoost + SVM provides better overall detection performance than AdaBoost or SVMs alone. Such results are the best ones known so far for the problem of automatic detection of Chagas parasites through the use of machine learning, computer vision, and image processing methods.

  2. The application of near-infrared spectra micro-image in the imaging analysis of biology samples

    Directory of Open Access Journals (Sweden)

    Dong Wang

    2014-07-01

    Full Text Available In this research, suitable imaging methods were used for acquiring single compound images of biology samples of chicken pectorales tissue section, tobacco dry leaf, fresh leaf and plant glandular hair, respectively. The adverse effects caused by the high water content and the thermal effect of near infrared (NIR light were effectively solved during the experiment procedures and the data processing. PCA algorithm was applied to the NIR micro-image of chicken pectorales tissue. Comparing the loading vector of PC3 with the NIR spectrum of dry albumen, the information of PC3 was confirmed to be provided mainly by protein, i.e., the 3rd score image represents the distribution trend of protein mainly. PCA algorithm was applied to the NIR micro-image of tobacco dry leaf. The information of PC2 was confirmed to be provided by carbohydrate including starch mainly. Compared to the 2nd score image of tobacco dry leaf, the compared correlation image with the reference spectrum of starch had the same distribution trend as the 2nd score image. The comparative correlation images with the reference spectra of protein, glucose, fructose and the total plant alkaloid were acquired to confirm the distribution trend of these compounds in tobacco dry leaf respectively. Comparative correlation images of fresh leaf with the reference spectra of protein, starch, fructose, glucose and water were acquired to confirm the distribution trend of these compounds in fresh leaf. Chemimap imaging of plant glandular hair was acquired to show the tubular structure clearly.

  3. Transformation of ATLA-negative leukocytes by blood components from anti-ATLA-positive donors in vitro.

    Science.gov (United States)

    Miyamoto, K; Tomita, N; Ishii, A; Nishizaki, T; Kitajima, K; Tanaka, T; Nakamura, T; Watanabe, S; Oda, T

    1984-06-15

    Anti-ATLA-positive blood components transformed healthy human leukocytes in vitro. Blood components examined were packed red cells, whole blood, platelet concentrate and fresh frozen plasma. Leukocytes present in anti-ATLA-positive blood components such as packed red cells, whole blood and platelet concentrate easily transformed anti-ATLA-negative leukocytes. Co-culture in fresh frozen plasma, however, did not transform recipient leukocytes, and leukocytes of anti-ATLA-positive recipients proved refractory to transformation. The transformed cells were morphologically lymphoid, grew in suspension, and possessed normal recipient karyotypes except in the case of three platelet concentrates. A high proportion of all the transformed populations formed E-rosettes with neuraminidase-treated sheep erythrocytes. The cytoplasm of over 90% of each recipient was stained brilliantly with antibodies against ATLV-determined antigens. Electron microscopy of these transformed cells revealed many C-type virus particles in the extracellular space. Blood components, such as packed red cells, whole blood and platelet concentrate, containing leukocytes from anti-ATLA-positive donors, should be used cautiously to prevent the transmission on ATLV to anti-ATLA-negative recipients.

  4. Imaging of cerebral blood flow in patients with severe traumatic brain injury in the neurointensive care.

    Directory of Open Access Journals (Sweden)

    Elham eRostami

    2014-07-01

    Full Text Available Ischemia is a common and deleterious secondary injury following traumatic brain injury (TBI. A great challenge for the treatment of TBI patients in the neurointensive care unit (NICU is to detect early signs of ischemia in order to prevent further advancement and deterioration of the brain tissue. Today, several imaging techniques are available to monitor cerebral blood flow (CBF in the injured brain such as Positron emission tomography (PET, Single-photon emission computed tomography (SPECT, Xenon-CT, perfusion weighted magnetic resonance imaging (MRI and CT perfusion scan. An ideal imaging technique would enable continuous noninvasive measurement of blood flow and metabolism across the whole brain. Unfortunately, no current imaging method meets all these criteria. These techniques offer snapshots of the CBF. MRI may also provide some information about the metabolic state of the brain. PET provides images with high resolution and quantitative measurements of CBF and metabolism however it is a complex and costly method limited to few TBI centres. All of these methods except mobile Xenon-CT require transfer of TBI patients to the radiological department. Mobile Xenon-CT emerges as a feasible technique to monitor CBF in the NICU, with lower risk of adverse effects. Promising results have been demonstrated with Xenon-CT in predicting outcome in TBI patients. This review covers available imaging methods used to monitor CBF in patients with severe TBI.

  5. Citrus fruits freshness assessment using Raman spectroscopy.

    Science.gov (United States)

    Nekvapil, Fran; Brezestean, Ioana; Barchewitz, Daniel; Glamuzina, Branko; Chiş, Vasile; Cintă Pinzaru, Simona

    2018-03-01

    The freshness of citrus fruits commonly available in the market was non-destructively assessed by Raman spectroscopy. Intact clementine, mandarin and tangerine species were characterised concerning their carotenoids skin Raman signalling in a time course from the moment they were acquired as fresh stock, supplying the market, to the physical degradation, when they were no longer attractive to consumers. The freshness was found to strongly correlate to the peel Raman signal collected from the same area of the intact fruits in a time course of a maximum of 20days. We have shown that the intensity of the carotenoid Raman signal is indeed a good indicator of fruit freshness and introduced a Raman coefficient of freshness (C Fresh ), whose time course is linearly decreasing, with different slope for different citrus groups. Additionally, we demonstrated that the freshness assessment could be achieved using a portable Raman instrument. The results could have a strong impact for consumer satisfaction and the food industry. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Early Blood Transfusion and Resolution of Disseminated Intravascular Coagulation Associated with Massive Subgaleal Hemorrhage.

    Science.gov (United States)

    Modanlou, Houchang; Hutson, Shandee; Merritt, Allan Thurman

    2016-01-01

    A male infant delivered to a primipara woman following vacuum applications. He was vigorous at birth, with small caput and scalp bruising. His head was enlarging; he became pale with respiratory distress. Subgaleal hemorrhage (SGH) was suspected. His hematocrit was noted to be 26.2 percent prior to transfusion of O, Rh-negative blood (40 mL/kg). Moderate disseminated intravascular coagulation (DIC) was noted at 12 hours of age. Posttransfusion of fresh frozen plasma (FFP), his condition became stable, and DIC gradually resolved. Head magnetic resonance imaging did not show intracranial hemorrhage. Although one episode of seizures was noted, electroencephalogram was normal. With the application of obstetric vacuum, we recommend that the neonatal health care professionals frequently evaluate the infant's condition. In light of developing fluctuant subgaleal fluid associated with pallor, anemia, metabolic acidosis, and respiratory distress, immediate blood transfusion is warranted. In the presence of DIC, transfusion of FFP is beneficial.

  7. Evaluation of Renal Blood Flow and Oxygenation in CKD Using Magnetic Resonance Imaging.

    Science.gov (United States)

    Khatir, Dinah S; Pedersen, Michael; Jespersen, Bente; Buus, Niels H

    2015-09-01

    Animal studies suggest that progression of chronic kidney disease (CKD) is related to renal hypoxia. With renal blood supply determining oxygen delivery and sodium absorption being the main contributor to oxygen consumption, we describe the relationship between renal oxygenation, renal artery blood flow, and sodium absorption in patients with CKD and healthy controls. Cross-sectional study. 62 stable patients with CKD stages 3 to 4 (mean age, 61±13 [SD] years) and 24 age- and sex-matched controls. CKD versus control status. Renal artery blood flow, tissue oxygenation (relative changes in deoxyhemoglobin concentration of the renal medulla [MR2*] and cortex [CR2*]), and sodium absorption. Renal artery blood flow was determined by phase-contrast magnetic resonance imaging (MRI); MR2* and CR2* were determined by blood oxygen level-dependent MRI. Ultrafiltered and reabsorbed sodium were determined from measured glomerular filtration rate (mGFR) and 24-hour urine collections. mGFR in patients was 37% that of controls (36±15 vs 97±23 mL/min/1.73 m(2); P renal artery blood flow was 72% that of controls (319 vs 443 mL/min; P renal artery blood flow or sodium absorption. Increasing arterial blood oxygen tension by breathing 100% oxygen had very small effects on CR2*, but reduced MR2* in both groups. Only renal artery blood flow was determined and thus regional perfusion could not be related to CR2* or MR2*. In CKD, reductions of mGFR and reabsorbed sodium are more than double that of renal artery blood flow, whereas cortical and medullary oxygenation are within the range of healthy persons. Reduction in glomerular filtration fraction may prevent renal hypoxia in CKD. Copyright © 2015 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  8. Frozen blood products: clinically effective and potentially ideal for remote Australia.

    Science.gov (United States)

    Holley, A; Marks, D C; Johnson, L; Reade, M C; Badloe, J F; Noorman, F

    2013-01-01

    The development of effective cryopreservation techniques for both red blood cells and platelets, which maintain ex vivo biological activity, in combination with frozen plasma, provides for a unique blood banking strategy. This technology greatly enhances the storage life of these products. The rationale and potential advantages of using cryopreservation techniques for the provision of blood products to remote and military environments have been effectively demonstrated in several conflicts over the last decade. Current haemostatic resuscitation doctrine for the exsanguinating patient supports the use of red blood cells, platelets and frozen plasma early in the resuscitation. We believe an integrated fresh-frozen blood bank inventory could facilitate provision of blood products, not only in the military setting but also in regional Australia, by overcoming many logistic and geographical challenges. The processes involved in production and point of care thawing are sufficiently well developed and achievable to make this technology a viable option. The potential limitations of cryopreservation and subsequent product thawing need to be considered if such a strategy is to be developed. A substantial body of international experience using cryopreserved products in remote settings has already been accrued. This experience provides a template for the possible creation of an Australian integrated fresh-frozen blood bank inventory that could conceivably enhance the care of patients in both regional Australia and in the military setting.

  9. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  10. Modelling the influence of noise of the image sensor for blood cells recognition in computer microscopy

    Science.gov (United States)

    Nikitaev, V. G.; Nagornov, O. V.; Pronichev, A. N.; Polyakov, E. V.; Dmitrieva, V. V.

    2017-12-01

    The first stage of diagnostics of blood cancer is the analysis of blood smears. The application of decision-making support systems would reduce the subjectivity of the diagnostic process and avoid errors, resulting in often irreversible changes in the patient's condition. In this regard, the solution of this problem requires the use of modern technology. One of the tools of the program classification of blood cells are texture features, and the task of finding informative among them is promising. The paper investigates the effect of noise of the image sensor to informative texture features with application of methods of mathematical modelling.

  11. Dynamic circular buffering: a technique for equilibrium gated blood pool imaging.

    Science.gov (United States)

    Vaquero, J J; Rahms, H; Green, M V; Del Pozo, F

    1996-03-01

    We have devised a software technique called "dynamic circular buffering" (DCB) with which we create a gated blood pool image sequence of the heart in real time using the best features of LIST and FRAME mode methods of acquisition/processing. The routine is based on the concept of independent "agents" acting on the timing and position data continuously written into the DCB. This approach allows efficient asynchronous operation on PC-type machines and enhanced capability on systems capable of true multiprocessing and multithreading.

  12. A CZT-based blood counter for quantitative molecular imaging.

    Science.gov (United States)

    Espagnet, Romain; Frezza, Andrea; Martin, Jean-Pierre; Hamel, Louis-André; Lechippey, Laëtitia; Beauregard, Jean-Mathieu; Després, Philippe

    2017-12-01

    Robust quantitative analysis in positron emission tomography (PET) and in single-photon emission computed tomography (SPECT) typically requires the time-activity curve as an input function for the pharmacokinetic modeling of tracer uptake. For this purpose, a new automated tool for the determination of blood activity as a function of time is presented. The device, compact enough to be used on the patient bed, relies on a peristaltic pump for continuous blood withdrawal at user-defined rates. Gamma detection is based on a 20 × 20 × 15 mm 3 cadmium zinc telluride (CZT) detector, read by custom-made electronics and a field-programmable gate array-based signal processing unit. A graphical user interface (GUI) allows users to select parameters and easily perform acquisitions. This paper presents the overall design of the device as well as the results related to the detector performance in terms of stability, sensitivity and energy resolution. Results from a patient study are also reported. The device achieved a sensitivity of 7.1 cps/(kBq/mL) and a minimum detectable activity of 2.5 kBq/ml for 18 F. The gamma counter also demonstrated an excellent stability with a deviation in count rates inferior to 0.05% over 6 h. An energy resolution of 8% was achieved at 662 keV. The patient study was conclusive and demonstrated that the compact gamma blood counter developed has the sensitivity and the stability required to conduct quantitative molecular imaging studies in PET and SPECT.

  13. Ground Zero/Fresh Kills: Cataloguing Ruins, Garbage, and Memory

    OpenAIRE

    Cinzia Scarpino

    2011-01-01

    The aim of this paper is to show how the rise and fall of the Twin Towers can be read in relation to the rise and fall of the Staten Island Fresh Kills landfill, how their destinies were entwined from the start, and how the immediate cultural response to the collapse of the former and the closing of the latter recurred to the form of catalogues of objects, words, and images. From this angle it will be possible to posit the events within a larger, if somewhat unusual, cultural frame encompassi...

  14. Estimating skin blood saturation by selecting a subset of hyperspectral imaging data

    Science.gov (United States)

    Ewerlöf, Maria; Salerud, E. Göran; Strömberg, Tomas; Larsson, Marcus

    2015-03-01

    Skin blood haemoglobin saturation (?b) can be estimated with hyperspectral imaging using the wavelength (λ) range of 450-700 nm where haemoglobin absorption displays distinct spectral characteristics. Depending on the image size and photon transport algorithm, computations may be demanding. Therefore, this work aims to evaluate subsets with a reduced number of wavelengths for ?b estimation. White Monte Carlo simulations are performed using a two-layered tissue model with discrete values for epidermal thickness (?epi) and the reduced scattering coefficient (μ's ), mimicking an imaging setup. A detected intensity look-up table is calculated for a range of model parameter values relevant to human skin, adding absorption effects in the post-processing. Skin model parameters, including absorbers, are; μ's (λ), ?epi, haemoglobin saturation (?b), tissue fraction blood (?b) and tissue fraction melanin (?mel). The skin model paired with the look-up table allow spectra to be calculated swiftly. Three inverse models with varying number of free parameters are evaluated: A(?b, ?b), B(?b, ?b, ?mel) and C(all parameters free). Fourteen wavelength candidates are selected by analysing the maximal spectral sensitivity to ?b and minimizing the sensitivity to ?b. All possible combinations of these candidates with three, four and 14 wavelengths, as well as the full spectral range, are evaluated for estimating ?b for 1000 randomly generated evaluation spectra. The results show that the simplified models A and B estimated ?b accurately using four wavelengths (mean error 2.2% for model B). If the number of wavelengths increased, the model complexity needed to be increased to avoid poor estimations.

  15. A Means for the Scintigraphic Imaging of Regional Brain Dynamics. Regional Cerebral Blood Flow and Regional Cerebral Blood Volume

    Energy Technology Data Exchange (ETDEWEB)

    Potchen, E. J.; Bentley, R.; Gerth, W.; Hill, R. L.; Davis, D. O. [Washington University School Of Medicine, St. Louis, MO (United States)

    1969-05-15

    The use of freely diffusable inert radioactive gas as a washout indicator to measure regional cerebral blood flow has become a standardized kinetic procedure in many laboratories. Recent investigations with this technique have led us to conclude that we can reliably distinguish regional flow with perfusion against regional flow without perfusion from the early portion of the curve. Based on a detailed study of the early curve kinetics in patients with and without cerebral vascular disease we have defined the sampling duration necessary for application of the Anger gamma camera imaging process to regional changes in cerebral radioactivity. Using a standard camera and a small computer, a procedure has been developed and based upon entire field to determine the time of maximum height followed by analysis of the data in a matrix. This will permit a contour plot presentation of calculated regional cerebral blood flow in millilitres per 100 grams perfused brain per minute. In addition, we propose to augment this data by the display of regional non-perfusion blood flow versus regional cerebral flow with perfusion. Preliminary investigation on sampling duration, and Compton scattering were prerequisite to clinical scintigraphy of regional cerebral blood flow. In addition, the method of interface for the conventional Anger gamma camera to digital computers used in this procedure are discussed. Applications to further assess regional cerebral dynamics by scintigraphy are presented. (author)

  16. A blood-mimicking fluid for particle image velocimetry with silicone vascular models

    Science.gov (United States)

    Yousif, Majid Y.; Holdsworth, David W.; Poepping, Tamie L.

    2011-03-01

    For accurate particle image velocimetry measurements in hemodynamics studies, it is important to use a fluid with a refractive index ( n) matching that of the vascular models (phantoms) and ideally a dynamic viscosity matching human blood. In this work, a blood-mimicking fluid (BMF) composed of water, glycerol, and sodium iodide was formulated for a range of refractive indices to match most common silicone elastomers ( n = 1.40-1.43) and with corresponding dynamic viscosity within the average cited range of healthy human blood (4.4 ± 0.5 cP). Both refractive index and viscosity were attained at room temperature (22.2 ± 0.2°C), which eliminates the need for a temperature-control system. An optimally matched BMF, suitable for use in a vascular phantom ( n = 1.4140 ± 0.0008, Sylgard 184), was demonstrated with composition (by weight) of 47.38% water, 36.94% glycerol (44:56 glycerol-water ratio), and 15.68% sodium iodide salt, resulting in a dynamic viscosity of 4 .31 ± 0 .03 cP.

  17. Oil palm fresh fruit bunch ripeness classification based on rule- based expert system of ROI image processing technique results

    International Nuclear Information System (INIS)

    Alfatni, M S M; Shariff, A R M; Marhaban, M H; Shafie, S B; Saaed, O M B; Abdullah, M Z; BAmiruddin, M D

    2014-01-01

    There is a processing need for a fast, easy and accurate classification system for oil palm fruit ripeness. Such a system will be invaluable to farmers and plantation managers who need to sell their oil palm fresh fruit bunch (FFB) for the mill as this will avoid disputes. In this paper,a new approach was developed under the name of expert rules-based systembased on the image processing techniques results of thethree different oil palm FFB region of interests (ROIs), namely; ROI1 (300x300 pixels), ROI2 (50x50 pixels) and ROI3 (100x100 pixels). The results show that the best rule-based ROIs for statistical colour feature extraction with k-nearest neighbors (KNN) classifier at 94% were chosen as well as the ROIs that indicated results higher than the rule-based outcome, such as the ROIs of statistical colour feature extraction with artificial neural network (ANN) classifier at 94%, were selected for further FFB ripeness inspection system

  18. Altered Potassium Ion Channel Function as a Possible Mechanism of Increased Blood Pressure in Rats Fed Thermally Oxidized Palm Oil Diets.

    Science.gov (United States)

    Nkanu, Etah E; Owu, Daniel U; Osim, Eme E

    2017-12-27

    Intake of thermally oxidized palm oil leads to cytotoxicity and alteration of the potassium ion channel function. This study investigated the effects of fresh and thermally oxidized palm oil diets on blood pressure and potassium ion channel function in blood pressure regulation. Male Wistar rats were randomly divided into three groups of eight rats. Control group received normal feed; fresh palm oil (FPO) and thermally oxidized palm oil (TPO) groups were fed a diet mixed with 15% (weight/weight) fresh palm oil and five times heated palm oil, respectively, for 16 weeks. Blood pressure was measured; blood samples, hearts, and aortas were collected for biochemical and histological analyses. Thermally oxidized palm oil significantly elevated basal mean arterial pressure (MAP). Glibenclamide (10 -5 mmol/L) and tetraethylammonium (TEA; 10 -3 mmol/L) significantly raised blood pressure in TPO compared with FPO and control groups. Levcromakalim (10 -6 mmol/L) significantly (p palm oil increases MAP probably due to the attenuation of adenosine triphosphate-sensitive potassium (K ATP ) and large-conductance calcium-dependent potassium (BK Ca ) channels, tissue peroxidation, and altered histological structures of the heart and blood vessels.

  19. Limiting the usage of blood products in cardiovascular surgery.

    Science.gov (United States)

    Horowitz, P E; Lorenzen, C M; Rhydderch, R D

    1991-03-01

    We studied the effect of the initiation of a five part program of blood component conservation on blood product utilization in patients undergoing major cardiovascular surgery. We encouraged physicians and nurses to adhere to a set of guidelines that would limit the exposure of these patients to complications associated with blood product administration. Through this effort the amounts of packed red cells, fresh frozen plasma, platelets, and cryoprecipitate used were markedly reduced. After the start of the conservation program, overall blood product usage was reduced 29% despite a 46% increase in the surgical caseload, and there was a 53% decrease in the amount of donor exposure (units of individual blood products administered) per patient.

  20. Ammonia blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003506.htm Ammonia blood test To use the sharing features on this page, ... Encephalopathy - ammonia; Cirrhosis - ammonia; Liver failure - ammonia Images Blood test References Chernecky CC, Berger BJ. Ammonia (NH3) - blood ...

  1. Rouleaux red blood cells splitting in microscopic thin blood smear images via local maxima, circles drawing, and mapping with original RBCs.

    Science.gov (United States)

    Rehman, Amjad; Abbas, Naveed; Saba, Tanzila; Mahmood, Toqeer; Kolivand, Hoshang

    2018-04-10

    Splitting the rouleaux RBCs from single RBCs and its further subdivision is a challenging area in computer-assisted diagnosis of blood. This phenomenon is applied in complete blood count, anemia, leukemia, and malaria tests. Several automated techniques are reported in the state of art for this task but face either under or over splitting problems. The current research presents a novel approach to split Rouleaux red blood cells (chains of RBCs) precisely, which are frequently observed in the thin blood smear images. Accordingly, this research address the rouleaux splitting problem in a realistic, efficient and automated way by considering the distance transform and local maxima of the rouleaux RBCs. Rouleaux RBCs are splitted by taking their local maxima as the centres to draw circles by mid-point circle algorithm. The resulting circles are further mapped with single RBC in Rouleaux to preserve its original shape. The results of the proposed approach on standard data set are presented and analyzed statistically by achieving an average recall of 0.059, an average precision of 0.067 and F-measure 0.063 are achieved through ground truth with visual inspection. © 2018 Wiley Periodicals, Inc.

  2. Simultaneous PET/MR imaging of the brain: feasibility of cerebral blood flow measurements with FAIR-TrueFISP arterial spin labeling MRI.

    Science.gov (United States)

    Stegger, Lars; Martirosian, Petros; Schwenzer, Nina; Bisdas, Sotirios; Kolb, Armin; Pfannenberg, Christina; Claussen, Claus D; Pichler, Bernd; Schick, Fritz; Boss, Andreas

    2012-11-01

    Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) with simultaneous data acquisition promises a comprehensive evaluation of cerebral pathophysiology on a molecular, anatomical, and functional level. Considering the necessary changes to the MR scanner design the feasibility of arterial spin labeling (ASL) is unclear. To evaluate whether cerebral blood flow imaging with ASL is feasible using a prototype PET/MRI device. ASL imaging of the brain with Flow-sensitive Alternating Inversion Recovery (FAIR) spin preparation and true fast imaging in steady precession (TrueFISP) data readout was performed in eight healthy volunteers sequentially on a prototype PET/MRI and a stand-alone MR scanner with 128 × 128 and 192 × 192 matrix sizes. Cerebral blood flow values for gray matter, signal-to-noise and contrast-to-noise ratios, and relative signal change were compared. Additionally, the feasibility of ASL as part of a clinical hybrid PET/MRI protocol was demonstrated in five patients with intracerebral tumors. Blood flow maps showed good delineation of gray and white matter with no discernible artifacts. The mean blood flow values of the eight volunteers on the PET/MR system were 51 ± 9 and 51 ± 7 mL/100 g/min for the 128 × 128 and 192 × 192 matrices (stand-alone MR, 57 ± 2 and 55 ± 5, not significant). The value for signal-to-noise (SNR) was significantly higher for the PET/MRI system using the 192 × 192 matrix size (P change (δS) was significantly lower for the 192 × 192 matrix size (P = 0.02). ASL imaging as part of a clinical hybrid PET/MRI protocol could successfully be accomplished in all patients in diagnostic image quality. ASL brain imaging is feasible with a prototype hybrid PET/MRI scanner, thus adding to the value of this novel imaging technique.

  3. Photoacoustic imaging of blood vessels with a double-ring sensor featuring a narrow angular aperture

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Hondebrink, Erwin; Steenbergen, Wiendelt; van Leeuwen, Ton; de Mul, F.F.M.

    2004-01-01

    A photoacoustic double-ring sensor, featuring a narrow angular aperture, is developed for laser-induced photoacoustic imaging of blood vessels. An integrated optical fiber enables reflection-mode detection of ultrasonic waves. By using the cross-correlation between the signals detected by the two

  4. Analysis of the stability of urea in dried blood spots collected and stored on filter paper.

    Science.gov (United States)

    Quraishi, Rizwana; Lakshmy, Ramakrishnan; Mukhopadhyay, Ashok Kumar; Jailkhani, Bansi Lal

    2013-05-01

    The ability to use dry blood spots (DBSs) on filter paper for the analysis of urea levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We developed a method for the extraction and quantification of urea from DBSs that were stored on 3M Whatman filter paper and investigated the effect of long-term storage on the level of urea in DBSs. DBSs of 4.5 mm in diameter were used for our assay, and we determined the urea levels in blood using a commercially available enzymatic kit (UV GLDH-method; Randox laboratories Ltd., UK). The DBSs on filter discs were stored at 4℃ or at 37℃ for 120 days. The mean intra- and inter-assay coefficient of variance for our method of urea extraction from dried blood was 4.2% and 6.3%, respectively. We collected 75 fresh blood samples and compared the urea content of each fresh sample with the urea content of DBSs taken from corresponding fresh blood samples. Regression analysis reported a regression coefficient (r) value of 0.97 and a recovery of urea from dried spots was 102.2%. Urea concentrations in DBSs were stable for up to 120 and 90 days when stored at 4℃ and 37℃, respectively. Our results show that urea can be stored and quantitatively recovered from small volumes of blood that was collected on filter paper.

  5. A review of suspension-Scattered particles used in blood-mimicking fluid for doppler ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Ammar A Oglat

    2018-01-01

    Full Text Available Doppler ultrasound imaging system description and calibration need blood-mimicking fluids (BMFs for the test target of medical ultrasound diagnostic tools, with known interior features and acoustic and physical properties of this fluid (BMF. Physical and acoustical properties determined in the International Electrotechnical Commission (IEC standard are specified as constant values, the materials used in the BMF preparation should have values similar to the IEC standard values. However, BMF is ready-made commercially from a field of medical usage, which may not be appropriate in the layout of ultrasound system or for an estimate of novel imaging mechanism. It is often eligible to have the capability to make sound properties and mimic blood arrangement for specific applications. In this review, sufficient BMF materials, liquids, and measures are described which have been generated by utilizing diverse operation mechanism and materials that have sculptured a range of biological systems.

  6. Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Tao; Tsui, Benjamin M. W.; Li, Xin; Vranesic, Melin; Lodge, Martin A.; Gulaldi, Nedim C. M.; Szabo, Zsolt, E-mail: zszabo@jhmi.edu [Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins School of Medicine, Baltimore, Maryland 21287 (United States)

    2015-11-15

    Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent

  7. Is the fresh water fish consumption a significant determinant of the internal exposure to perfluoroalkylated substances (PFAS)?

    Science.gov (United States)

    Denys, Sébastien; Fraize-Frontier, Sandrine; Moussa, Oumar; Le Bizec, Bruno; Veyrand, Bruno; Volatier, Jean-Luc

    2014-12-01

    PFAS are man-made compounds that are highly spread in the environment. Human dietary exposure to such contaminants is of high concern as they may accumulate in the food chain. Different studies already demonstrated the importance of the fish consumption in the dietary exposure of these molecules and the potential increase of internal doses of PFAS following the consumption of PFAS. However, so far few study aimed to study the link between the consumption of fresh water fishes and the internal exposure to PFAS. Objectives of this study were (i) to estimate the internal exposure of populations that are potentially high consumers of fresh water fishes and (ii) to determine whether the consumption of fish caught from fresh water is a significant determinant of the internal exposure of PFAS. In this work, a large sample of adult freshwater anglers from the French metropolitan population (478 individuals) was constituted randomly from participants lists of anglers associations. Questionnaires provided social and demographic information and diet information for each subject. In addition, analyses of blood serum samples provided the internal concentration of 14 PFAS. The survey design allowed to extrapolate the data obtained on the 478 individuals to the freshwater angler population. Descriptive data regarding internal levels of PFAS were discussed at the population level, whereas identification of the determinants were done at the 478 individuals level as sufficient contrast was required in terms of fresh water fish consumption. Only molecules for which the detection frequency were above 80% in blood were considered, i.e., PFOS, PFOA, PFHxS, PFNA, PFHpS, and PFDA. Distribution profiles showed log-normal distribution and PFOS and PFOA were the main contributors of the PFAS sum. For PFOS, the results obtained on the 478 individuals showed that upper percentiles were higher as compared to upper percentiles obtained on occidental general population. This confirmed an over

  8. Long-Term Stored Hemoglobin-Vesicles, a Cellular Type of Hemoglobin-Based Oxygen Carrier, Has Resuscitative Effects Comparable to That for Fresh Red Blood Cells in a Rat Model with Massive Hemorrhage without Post-Transfusion Lung Injury.

    Directory of Open Access Journals (Sweden)

    Masahiro Tokuno

    Full Text Available Hemoglobin-vesicles (HbV, encapsulating highly concentrated human hemoglobin in liposomes, were developed as a substitute for red blood cells (RBC and their safety and efficacy in transfusion therapy has been confirmed in previous studies. Although HbV suspensions are structurally and physicochemically stabile for least 1-year at room temperature, based on in vitro experiments, the issue of whether the use of long-term stored HbV after a massive hemorrhage can be effective in resuscitations without adverse, post-transfusion effects remains to be clarified. We report herein on a comparison of the systemic response and the induction of organ injuries in hemorrhagic shock model rats resuscitated using 1-year-stored HbV, freshly packed RBC (PRBC-0 and by 28-day-stored packed RBC (PRBC-28. The six-hour mortality after resuscitation was not significantly different among the groups. Arterial blood pressure and blood gas parameters revealed that, using HbV, recovery from the shock state was comparable to that when PRBC-0 was used. Although no significant change was observed in serum parameters reflecting liver and kidney injuries at 6 hours after resuscitation among the three resuscitation groups, results based on Evans Blue and protein leakage in bronchoalveolar lavage fluid, the lung wet/dry weight ratio and histopathological findings indicated that HbV as well as PRBC-0 was less predisposed to result in a post-transfusion lung injury than PRBC-28, as evidenced by low levels of myeloperoxidase accumulation and subsequent oxidative damage in the lung. The findings reported herein indicate that 1-year-stored HbV can effectively function as a resuscitative fluid without the induction of post-transfused lung injury and that it is comparable to fresh PRBC, suggesting that HbV is a promising RBC substitute with a long shelf-life.

  9. Comparative biomechanical study between fresh frozen bone and fresh frozen pasteurized bone process

    International Nuclear Information System (INIS)

    Ferdiansyah Abdurrahman

    1999-01-01

    To observe the biomechanical properties difference between fresh frozen bone and fresh frozen pasteurized bone process Thirty eight femurs bones taken from 6 years old primate.(macaca fascicularis) from Primate Nursery Center LIPI Bogor, 20 bones were 6 cm cut for bending test and 18 remains were 3 cm cut for compression test. All bones were frozen and then divided into two groups for each biomechanical study. First group (I 0 bones for bending test and 9 bones for compression test) were undergone fresh frozen procession only. The second group with the same amount was undergone fresh frozen and pasteurized on 60 degree C for three hours. Bending test was done until the bones were broken on control group and pasteurized group and the result was compared, the same procedure was done for compression test. The study was done in room temperature. The biomechanical test result was analyzed by two independent T tests. The bending test control group has ( mean 0.097 N / mm sup 2 (SD = 0.007) and the pasteurized group ( mean 0. I 0 1 N / mm sup 2 (SD = 0.0 1 3), there was no significant difference (p 0.399). The compression test control group has ( = mean 0.71 N / mm sup 2 (SD=0.128)where as the pasteurized group has(mean 0.50N/mm sup 2 (SD=0.111),there was significant difference (p =0.004) From the result biomechanical study on bending test, there was no significant difference of bone strength, whereas on compression test the fresh frozen with pasteurized bone group is 125% stronger than control group. The result of this study will be very useful for reconstruction bone allograft

  10. Evaluating the effect of sample type on American alligator (Alligator mississippiensis) analyte values in a point-of-care blood analyser.

    Science.gov (United States)

    Hamilton, Matthew T; Finger, John W; Winzeler, Megan E; Tuberville, Tracey D

    2016-01-01

    The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressure of carbon dioxide (PCO2), bicarbonate (HCO3 (-)), total carbon dioxide (TCO2), base excess (BE), partial pressure of oxygen (PO2), oxygen saturation (sO2) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. Lastly, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.

  11. Absolute quantification of regional renal blood flow in swine by dynamic contrast-enhanced magnetic resonance imaging using a blood pool contrast agent.

    Science.gov (United States)

    Lüdemann, Lutz; Nafz, Benno; Elsner, Franz; Grosse-Siestrup, Christian; Meissler, Michael; Kaufels, Nicola; Rehbein, Hagen; Persson, Pontus B; Michaely, Henrik J; Lengsfeld, Philipp; Voth, Matthias; Gutberlet, Matthias

    2009-03-01

    To evaluate for the first time in an animal model the possibility of absolute regional quantification of renal medullary and cortical perfusion by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a blood pool contrast agent. A total of 18 adult female pigs (age, 16-22 weeks; body weight, 45-65 kg; no dietary restrictions) were investigated by DCE-MRI. Absolute renal blood flow (RBF) measured by an ultrasound transit time flow probe around the renal vein was used as the standard of reference. An inflatable stainless cuff placed around the renal artery near its origin from the abdominal aorta was used to reduce RBF to 60%, 40%, and 20% of the baseline flow. The last measurement was performed with the cuff fully reopened. Absolute RBF values during these 4 perfusion states were compared with the results of DCE-MRI performed on a 1.5-T scanner with an 8-channel phased-array surface coil. All scans were acquired in breath-hold technique in the coronal plane using a field of view of 460 mm.Each dynamic scan commenced with a set of five 3D T1-weighted gradient echo sequences with different flip angles (alpha = 2 degrees, 5 degrees, 10 degrees, 20 degrees, 30 degrees): TE, 0.88 milliseconds; TR, 2.65 milliseconds; slice thickness, 8.8 mm for 4 slices; acquisition matrix, 128 x 128; and acquisitions, 4. These data served to calculate 3D intrinsic longitudinal relaxation rate maps (R10) and magnetization (M0). Immediately after these images, the dynamic 3D T1-weighted gradient echo images were acquired with the same parameters and a constant alpha = 30 degrees, half Fourier, 1 acquisition, 64 frames, a time interval of 1.65 seconds between each frame, and a total duration of 105.6. Three milliliters of an albumin-binding blood pool contrast agent (0.25 mmol/mL gadofosveset trisodium, Vasovist, Bayer Schering Pharma AG, Berlin, Germany) was injected at a rate of 3 mL/s. Perfusion was calculated using the arterial input function from the aorta, which was

  12. Parametrically defined cerebral blood vessels as non-invasive blood input functions for brain PET studies

    International Nuclear Information System (INIS)

    Asselin, Marie-Claude; Cunningham, Vincent J; Amano, Shigeko; Gunn, Roger N; Nahmias, Claude

    2004-01-01

    A non-invasive alternative to arterial blood sampling for the generation of a blood input function for brain positron emission tomography (PET) studies is presented. The method aims to extract the dimensions of the blood vessel directly from PET images and to simultaneously correct the radioactivity concentration for partial volume and spillover. This involves simulation of the tomographic imaging process to generate images of different blood vessel and background geometries and selecting the one that best fits, in a least-squares sense, the acquired PET image. A phantom experiment was conducted to validate the method which was then applied to eight subjects injected with 6-[ 18 F]fluoro-L-DOPA and one subject injected with [ 11 C]CO-labelled red blood cells. In the phantom study, the diameter of syringes filled with an 11 C solution and inserted into a water-filled cylinder were estimated with an accuracy of half a pixel (1 mm). The radioactivity concentration was recovered to 100 ± 4% in the 8.7 mm diameter syringe, the one that most closely approximated the superior sagittal sinus. In the human studies, the method systematically overestimated the calibre of the superior sagittal sinus by 2-3 mm compared to measurements made in magnetic resonance venograms on the same subjects. Sources of discrepancies related to the anatomy of the blood vessel were found not to be fundamental limitations to the applicability of the method to human subjects. This method has the potential to provide accurate quantification of blood radioactivity concentration from PET images without the need for blood samples, corrections for delay and dispersion, co-registered anatomical images, or manually defined regions of interest

  13. Imaging tumor hypoxia: Blood-borne delivery of imaging agents is fundamentally different in hypoxia subtypes

    Directory of Open Access Journals (Sweden)

    Peter Vaupel

    2014-03-01

    Full Text Available Hypoxic tissue subvolumes are a hallmark feature of solid malignant tumors, relevant for cancer therapy and patient outcome because they increase both the intrinsic aggressiveness of tumor cells and their resistance to several commonly used anticancer strategies. Pathogenetic mechanisms leading to hypoxia are diverse, may coexist within the same tumor and are commonly grouped according to the duration of their effects. Chronic hypoxia is mainly caused by diffusion limitations resulting from enlarged intercapillary distances and adverse diffusion geometries and — to a lesser extent — by hypoxemia, compromised perfusion or long-lasting microregional flow stops. Conversely, acute hypoxia preferentially results from transient disruptions in perfusion. While each of these features of the tumor microenvironment can contribute to a critical reduction of oxygen availability, the delivery of imaging agents (as well as nutrients and anticancer agents may be compromised or remain unaffected. Thus, a critical appraisal of the effects of the various mechanisms leading to hypoxia with regard to the blood-borne delivery of imaging agents is necessary to judge their ability to correctly represent the hypoxic phenotype of solid malignancies.

  14. Scintigraphic detection of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging

    Energy Technology Data Exchange (ETDEWEB)

    Georgiou, E C; Arkas, A Z; Alevizaki, C C; Gnafakis, N [Evangelismos Hospital, Athens (Greece). Dept. of Endocrinology and Radioisotopes; Evangelismos Hospital, Athens (Greece). Gynaecology Clinic)

    1979-12-01

    Three cases of scintigraphic visualization of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging are presented, i.e. one case of fibrothecoma ('cold' area visualization) and two cases of fibromyoma ('hot' area visualization). It is suggested that this technique may be useful in the preoperative evaluation of gynaecological tumours and their vascularity.

  15. Non invasive blood flow assessment in diabetic foot ulcer using laser speckle contrast imaging technique

    Science.gov (United States)

    Jayanthy, A. K.; Sujatha, N.; Reddy, M. Ramasubba; Narayanamoorthy, V. B.

    2014-03-01

    Measuring microcirculatory tissue blood perfusion is of interest for both clinicians and researchers in a wide range of applications and can provide essential information of the progress of treatment of certain diseases which causes either an increased or decreased blood flow. Diabetic ulcer associated with alterations in tissue blood flow is the most common cause of non-traumatic lower extremity amputations. A technique which can detect the onset of ulcer and provide essential information on the progress of the treatment of ulcer would be of great help to the clinicians. A noninvasive, noncontact and whole field laser speckle contrast imaging (LSCI) technique has been described in this paper which is used to assess the changes in blood flow in diabetic ulcer affected areas of the foot. The blood flow assessment at the wound site can provide critical information on the efficiency and progress of the treatment given to the diabetic ulcer subjects. The technique may also potentially fulfill a significant need in diabetic foot ulcer screening and management.

  16. Arterial spin labeling blood flow magnetic resonance imaging for evaluation of renal injury.

    Science.gov (United States)

    Liu, Yupin P; Song, Rui; Liang, Chang hong; Chen, Xin; Liu, Bo

    2012-08-15

    A multitude of evidence suggests that iodinated contrast material causes nephrotoxicity; however, there have been no previous studies that use arterial spin labeling (ASL) blood flow functional magnetic resonance imaging (fMRI) to investigate the alterations in effective renal plasma flow between normointensive and hypertensive rats following injection of contrast media. We hypothesized that FAIR-SSFSE arterial spin labeling MRI may enable noninvasive and quantitative assessment of regional renal blood flow abnormalities and correlate with disease severity as assessed by histological methods. Renal blood flow (RBF) values of the cortex and medulla of rat kidneys were obtained from ASL images postprocessed at ADW4.3 workstation 0.3, 24, 48, and 72 h before and after injection of iodinated contrast media (6 ml/kg). The H&E method for morphometric measurements was used to confirm the MRI findings. The RBF values of the outer medulla were lower than those of the cortex and the inner medulla as reported previously. Iodinated contrast media treatment resulted in decreases in RBF in the outer medulla and cortex in spontaneously hypertensive rats (SHR), but only in the outer medulla in normotensive rats. The iodinated contrast agent significantly decreased the RBF value in the outer medulla and the cortex in SHR compared with normotensive rats after injection of the iodinated contrast media. Histological observations of kidney morphology were also consistent with ASL perfusion changes. These results demonstrate that the RBF value can reflect changes of renal perfusion in the cortex and medulla. ASL-MRI is a feasible and accurate method for evaluating nephrotoxic drugs-induced kidney damage.

  17. Comparison on hypoglycemic and antioxidant activities of the fresh and dried Portulaca oleracea L. in insulin-resistant HepG2 cells and streptozotocin-induced C57BL/6J diabetic mice.

    Science.gov (United States)

    Gu, Jun-Fei; Zheng, Zhi-Yin; Yuan, Jia-Rui; Zhao, Bing-Jie; Wang, Chun-Fei; Zhang, Li; Xu, Qing-Yu; Yin, Guo-Wen; Feng, Liang; Jia, Xiao-Bin

    2015-02-23

    Fresh Portulaca oleracea L. (family: Portulacaceae; POL) has been used as a folk medicine for the treatment of diabetes mellitus for a long time. More bioactive components with higher activity could be retained in fresh medicinal herbs compared to the dried ones. The present study was conducted to compare different antidiabetic activity between fresh and dried POL, including hypoglycemic and antioxidant activities both in vivo and in vitro. Furthermore, in order to explore which components were responsible for the antidiabetic activity, the difference on chemical components between fresh and dried POL was analyzed and compared. Insulin-resistant HepG2 cells induced by insulin were used to evaluate the promoting effect of the fresh and dried POL on glucose utilization in vitro. Streptozotocin (STZ)-induced C57BL/6J diabetic mice were used to compare the differences on hypoglycemic and antioxidant activities of fresh and dried POL, including the fasting blood glucose, glucose tolerance, serum insulin level, malondialdehyde (MDA) level and superoxide dismutase (SOD) activity in vivo. UPLC/Q-TOF-MS method was performed to analyze the difference of antidiabetic components between fresh and dried POL. Compared with the dried POL extract, the fresh POL extract significantly increased the consumption of extracellular glucose in insulin-resistant HepG2 cells (P<0.05). In STZ-induced C57BL/6J diabetic mice, both fresh and dried extracts decreased markedly the fasting blood glucose (FBG) levels, and improved significantly oral glucose tolerance test (OGTT), as well as enhanced significantly insulin secretion and antioxidative activities (P<0.05; P<0.01). Furthermore, the fresh extract showed stronger antidiabetic activity (P<0.05). The UPLC/Q-TOF-MS analysis results also revealed that the relative contents of polyphenols and alkaloids in the fresh herbs were more abundant than those in the dried POL. Our results indicated that both fresh and dried POL possessed antidiabetic

  18. Quality indicators for discarding blood in the National Blood Center, Kuala Lumpur

    Directory of Open Access Journals (Sweden)

    Mohammed Morish

    2012-01-01

    Full Text Available Background and Objective: The implementation of quality system and continuous evaluation of all activities of the Blood Transfusion Services (BTS can help to achieve the maximum quantity and quality of safe blood. Optimizing blood collection and processing would reduce the rate of discard and improve the efficiency of the BTS. The objective of this study is to determine the rate of discard of blood and blood component and identify its reasons at the National Blood Centre (NBC, Kuala Lumpur, during the year of 2007 in order to introduce appropriate intervention. Study Designs and Methods: Data on the number of discarded whole blood units and its components, reasons for discard, and the number of blood components processed as well as the number of collected blood units were obtained from the Blood Bank Information System - NBC database. These were analyzed. Results: The total number of blood units collected in 2007 was 171169 from which 390636 units of components were prepared. The total number of discarded whole blood units and its components was 8968 (2.3%. Platelet concentrate recorded the highest of discard at 6% (3909 followed by whole blood at 3.7% (647, fresh frozen plasma (FFP at 2.5% (2839, and cryoprecipitate at 2% (620. The rate of discarded packed red blood cells RBCs, plasma aphaeresis, and PLT aphaeresis was less than 1% at 0.6% (902, 0.6% (37, and 0.29% (14, respectively. RBC contamination of PLT and plasma were the major cause of discard at 40% (3558. Other causes include leakage (26% - 2306, lipemia (25% - 2208, and underweight (4% - 353. Conclusion: Good donor selection, training and evaluation of the staff, as well as implementation of automation will help to improve processes and output of BTS. This would reduce discard of blood components and wastage caused by non conformance.

  19. Dark blood versus bright blood T2* acquisition in cardiovascular magnetic resonance (CMR) for thalassaemia major (TM) patients: Evaluation of feasibility, reproducibility and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Liguori, Carlo, E-mail: c.liguori@unicampus.it [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Di Giampietro, Ilenia; Pitocco, Francesca; De Vivo, Aldo Eros [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Schena, Emiliano [Unit of Measurements and Biomedical Instrumentation, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Mortato, Luca [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy); Pirro, Federica [Department of Biomaging and Radiological Sciences, Catholic University of Sacred Herart, Largo A. Gemelli 1, 00135 Rome (Italy); Cianciulli, Paolo [Thalassemia Unit, Ospedale Sant Eugenio, Piazzale dell’Umanesimo 10, 00143 Rome (Italy); Zobel, Bruno Beomonte [Department of Diagnostic Imaging, Campus Bio Medico University, via Alvaro del Portillo 200, 00128 Rome (Italy)

    2014-01-15

    Objectives: To compare the effectiveness of dark blood (DB) versus bright blood (BB) sequences. To assess the intra and inter-observer variability and inter-study reproducibility between BB versus DB. To evaluate image quality level in the two sequences. Methods: In a setting of 138 patients we performed CMR using cardiac gated Gradient-multiecho single breath-hold BB and DB sequences in the middle ventricular septum. Each acquisition was repeated during the same exam. Truncation method was used to account for background noise. Image quality (IQ) was assessed using a 5 point grading scale and image analysis was conducted by 2 experienced observers. Results: Compared with the conventional BB acquisition, the coefficient of correlation and significance of the DB technique was superior for intra-observer reproducibility (p < 0.001), inter-observer reproducibility (p < 0.001) and inter-study reproducibility (p < 0.001). The variability is also lower for DB sequences for T2* values <14 ms. Assessment of artifacts showed a superior score for DB versus BB scans (4 versus 3, p < 0.001). Conclusions: Improvement in terms of inter observer and inter study variability using DB sequences was obtained. The greatest disparity between them was seen in inter-study reproducibility and higher IQ in DB was seen. Study demonstrates better performance of DB imaging compared to BB in presence of comparable effectiveness.

  20. Automatic localization of the left ventricular blood pool centroid in short axis cardiac cine MR images.

    Science.gov (United States)

    Tan, Li Kuo; Liew, Yih Miin; Lim, Einly; Abdul Aziz, Yang Faridah; Chee, Kok Han; McLaughlin, Robert A

    2018-06-01

    In this paper, we develop and validate an open source, fully automatic algorithm to localize the left ventricular (LV) blood pool centroid in short axis cardiac cine MR images, enabling follow-on automated LV segmentation algorithms. The algorithm comprises four steps: (i) quantify motion to determine an initial region of interest surrounding the heart, (ii) identify potential 2D objects of interest using an intensity-based segmentation, (iii) assess contraction/expansion, circularity, and proximity to lung tissue to score all objects of interest in terms of their likelihood of constituting part of the LV, and (iv) aggregate the objects into connected groups and construct the final LV blood pool volume and centroid. This algorithm was tested against 1140 datasets from the Kaggle Second Annual Data Science Bowl, as well as 45 datasets from the STACOM 2009 Cardiac MR Left Ventricle Segmentation Challenge. Correct LV localization was confirmed in 97.3% of the datasets. The mean absolute error between the gold standard and localization centroids was 2.8 to 4.7 mm, or 12 to 22% of the average endocardial radius. Graphical abstract Fully automated localization of the left ventricular blood pool in short axis cardiac cine MR images.

  1. Altered Blood-Brain Barrier Permeability in Patients With Systemic Lupus Erythematosus: A Novel Imaging Approach.

    Science.gov (United States)

    Gulati, Gaurav; Jones, Jordan T; Lee, Gregory; Altaye, Mekibib; Beebe, Dean W; Meyers-Eaton, Jamie; Wiley, Kasha; Brunner, Hermine I; DiFrancesco, Mark W

    2017-02-01

    To evaluate a safe, noninvasive magnetic resonance imaging (MRI) method to measure regional blood-brain barrier integrity and investigate its relationship with neurocognitive function and regional gray matter volume in juvenile-onset systemic lupus erythematosus (SLE). In this cross-sectional, case-control study, capillary permeability was measured as a marker of blood-brain barrier integrity in juvenile SLE patients and matched healthy controls, using a combination of arterial spin labeling and diffusion-weighted brain MRI. Regional gray matter volume was measured by voxel-based morphometry. Correlation analysis was done to investigate the relationship between regional capillary permeability and regional gray matter volume. Formal neurocognitive testing was completed (measuring attention, visuoconstructional ability, working memory, and psychomotor speed), and scores were regressed against regional blood-brain barrier integrity among juvenile SLE patients. Formal cognitive testing confirmed normal cognitive ability in all juvenile SLE subjects (n = 11) included in the analysis. Regional capillary permeability was negatively associated (P = 0.026) with neurocognitive performance concerning psychomotor speed in the juvenile SLE cohort. Compared with controls (n = 11), juvenile SLE patients had significantly greater capillary permeability involving Brodmann's areas 19, 28, 36, and 37 and caudate structures (P < 0.05 for all). There is imaging evidence of increased regional capillary permeability in juvenile SLE patients with normal cognitive performance using a novel noninvasive MRI technique. These blood-brain barrier outcomes appear consistent with functional neuronal network alterations and gray matter volume loss previously observed in juvenile SLE patients with overt neurocognitive deficits, supporting the notion that blood-brain barrier integrity loss precedes the loss of cognitive ability in juvenile SLE. Longitudinal studies are needed to

  2. Prolonged storage of packed red blood cells for blood transfusion.

    Science.gov (United States)

    Martí-Carvajal, Arturo J; Simancas-Racines, Daniel; Peña-González, Barbra S

    2015-07-14

    A blood transfusion is an acute intervention, used to address life- and health-threatening conditions on a short-term basis. Packed red blood cells are most often used for blood transfusion. Sometimes blood is transfused after prolonged storage but there is continuing debate as to whether transfusion of 'older' blood is as beneficial as transfusion of 'fresher' blood. To assess the clinical benefits and harms of prolonged storage of packed red blood cells, in comparison with fresh, on recipients of blood transfusion. We ran the search on 1st May 2014. We searched the Cochrane Injuries Group Specialized Register, Cochrane Central Register of Controlled Trials (CENTRAL, The Cochrane Library), MEDLINE (OvidSP), Embase (OvidSP), CINAHL (EBSCO Host) and two other databases. We also searched clinical trials registers and screened reference lists of the retrieved publications and reviews. We updated this search in June 2015 but these results have not yet been incorporated. Randomised clinical trials including participants assessed as requiring red blood cell transfusion were eligible for inclusion. Prolonged storage was defined as red blood cells stored for ≥ 21 days in a blood bank. We did not apply limits regarding the duration of follow-up, or country where the study took place. We excluded trials where patients received a combination of short- and long-stored blood products, and also trials without a clear definition of prolonged storage. We independently performed study selection, risk of bias assessment and data extraction by at least two review authors. The major outcomes were death from any cause, transfusion-related acute lung injury, and adverse events. We estimated relative risk for dichotomous outcomes. We measured statistical heterogeneity using I(2). We used a random-effects model to synthesise the findings. We identified three randomised clinical trials, involving a total of 120 participants, comparing packed red blood cells with ≥ 21 days storage

  3. SU-F-J-222: Using PET Imaging to Evaluate Proliferation and Blood Flow in Irradiated and Non-Irradiated Bone Marrow 1 Year After Chemoradiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, S; Ponto, L; Menda, Y [University Of Iowa, Iowa City, IA (United States)

    2016-06-15

    Purpose: To compare proliferation and blood flow in pelvic and thoracic bone marrow 1 year after pelvic chemoradiation. Methods: Sixteen pelvic cancer patients were enrolled in an IRB-approved protocol to acquire FLT PET images during radiation therapy simulation (baseline) and 1 year after chemoradiation therapy. Three subjects also had optional O-15 water PET images acquired 1 year after chemoradiation therapy. Baseline FLT PET images were used to create IMRT plans to spare pelvic bone marrow identified as regions with FLT SUV ≥ 2 without compromising PTV coverage or OAR sparing. Marrow VOIs were defined using a 50% maximum pixel value threshold on baseline FLT PET images (VIEW, PMOD version 3.5) in the sacrum and thoracic spine representing irradiated and non-irradiated regions, respectively. FLT PET and O-15 water PET images acquired 1 year after therapy were co-registered to baseline images (FUSION PMOD) and the same VOIs were used to measure proliferation (FLT SUV) and blood flow (O-15 water uptake). Separate image-based input functions were used for blood flow quantitation in each VOI. Results: Mean 1 year FLT SUV in sacral and thoracic VOIs for were 1.1 ± 0.4 and 6.5 ± 1.7, respectively for N = 16 subjects and were 1.2 ± 0.2 and 5.6 ± 1.6, respectively for N = 3 subjects who also underwent O-15 water imaging. Blood flow measures in equivalent sacral and thoracic marrow regions (N = 3) were 21.3 ± 8.7 and 18.3 ± 4.9 mL/min/100mL respectively. Conclusion: Decreased bone marrow proliferation measured by FLT SUV does not appear to correspond to decreased blood flow as measured by O-15 water PET imaging. Based on this small sample at a single time point, reduced blood supply does not explain reductions in bone marrow proliferative activity 1 year after chemoradiation therapy.

  4. Modeling of Cerebral Oxygen Transport Based on In vivo Microscopic Imaging of Microvascular Network Structure, Blood Flow, and Oxygenation.

    Science.gov (United States)

    Gagnon, Louis; Smith, Amy F; Boas, David A; Devor, Anna; Secomb, Timothy W; Sakadžić, Sava

    2016-01-01

    Oxygen is delivered to brain tissue by a dense network of microvessels, which actively control cerebral blood flow (CBF) through vasodilation and contraction in response to changing levels of neural activity. Understanding these network-level processes is immediately relevant for (1) interpretation of functional Magnetic Resonance Imaging (fMRI) signals, and (2) investigation of neurological diseases in which a deterioration of neurovascular and neuro-metabolic physiology contributes to motor and cognitive decline. Experimental data on the structure, flow and oxygen levels of microvascular networks are needed, together with theoretical methods to integrate this information and predict physiologically relevant properties that are not directly measurable. Recent progress in optical imaging technologies for high-resolution in vivo measurement of the cerebral microvascular architecture, blood flow, and oxygenation enables construction of detailed computational models of cerebral hemodynamics and oxygen transport based on realistic three-dimensional microvascular networks. In this article, we review state-of-the-art optical microscopy technologies for quantitative in vivo imaging of cerebral microvascular structure, blood flow and oxygenation, and theoretical methods that utilize such data to generate spatially resolved models for blood flow and oxygen transport. These "bottom-up" models are essential for the understanding of the processes governing brain oxygenation in normal and disease states and for eventual translation of the lessons learned from animal studies to humans.

  5. Inheritance of fresh-cut fruit quality attributes in Capsicum

    Science.gov (United States)

    The fresh-cut fruit and vegetable industry has expanded rapidly during the past decade, due to freshness, convenience and the high nutrition that fresh-cut produce offers to consumers. The current report evaluates the inheritance of postharvest attributes that contribute to pepper fresh-cut product...

  6. Quality of intraoperative autologous blood withdrawal used for retransfusion after cardiopulmonary bypass.

    Science.gov (United States)

    Flom-Halvorsen, Hanne I; Øvrum, Eivind; Øystese, Rolf; Brosstad, Frank

    2003-09-01

    Intraoperative autologous blood withdrawal protects the pooled blood from the deleterious effects of cardiopulmonary bypass. Following reinfusion after cardiopulmonary bypass, the fresh autologous blood contributes to less coagulation abnormalities and reduces postoperative bleeding and the need for allogeneic blood products. However, few data have been available concerning the quality and potential activation of fresh blood stored at room temperature in the operating room. Forty coronary artery bypass grafting patients undergoing a consistent intraoperative and postoperative autotransfusion protocol had a median of 1,000 mL of autologous blood withdrawn before cardiopulmonary bypass. After heparinization the blood was drained from the venous catheter via venous cannula into standard blood bags and stored in the operating room until termination of cardiopulmonary bypass. Samples for hemostatic and inflammatory markers were taken from the pooled blood immediately before it was returned to the patient. There was some activation of platelets in the stored autologous blood, as measured by an increase of beta-thromboglobulin. Indications of thrombin formation, as assessed by plasma levels of thrombin-antithrombin complex and prothrombin fragment 1.2 were not seen, and there was no fibrinolytic activity. The red blood cells remained intact, indicated by the absence of plasma free hemoglobin. As for the inflammatory response, the levels of the terminal complement complex remained stable, and the cytokines tumor necrosis factor-alpha and interleukin 6 levels were not increased during storage. The complement activation products increased minimally, but remained within normal ranges. Except for slight activation of platelets, there was no indication of coagulation, hemolysis, fibrinolysis, or immunologic activity in the autologous blood after approximately 1 hour of operating room storage. The autologous blood was preserved in a condition of high quality, and retransfusion

  7. Justifying the clinical use of fresh frozen plasma-an audit

    International Nuclear Information System (INIS)

    Sharif, M.M.; Maqbool, S.; Butt, T.K.; Iqbal, S.; Mumtaz, A.

    2007-01-01

    To determine the appropriateness of fresh frozen plasma (FFP), uses in various haematological and clinical disorders, with reference to the British Committee for Standards in Haematology (BCSH) guidelines through an audit. The data was collected from June 2001 to June 2004 from the request forms ordered by the clinicians for the transfusion of FFP at the Department of Haematology and Transfusion Medicine, Shalamar Hospital, Lahore. A total of 2075 healthy blood donors donated their whole blood for the preparation of fresh frozen plasma (FFP). All blood donors were screened for anti HCV, HBsAg, VDRL and HIV. Those 2075 FFP units were prepared on high-speed centrifuge and were rapidly stored at -30 degree C freezer. A total of 587 patients were transfused 2075 units of FFP for various clinical disorders. The percentage of FFP units, transfused appropriately and inappropriately, as defined by BCSH guidelines, was estimated. Out of 2075 FFP units, 335 (24.41%) FFP units were transfused to patients suffering from bleeding due to disseminated intravascular coagulation (DIC), 306 (22.30%) units used for massive transfusion and surgical bleeding, 236 (17.20%) units for bleeding due to chronic liver disease, 202 (14.72%) units used to control bleeding due to coagulation factor deficiencies, 84(6.12%) units for thrombotic thrombocytopenic purpura (TTP), 75(5.46%) units prior to liver biopsy to correct prolonged prothrombin time (PT), 72(5.24%) units for haemorrhage due to haemolytic disease of newborn (HDN) and 62(4.51%) units to control bleeding due to warfarin overdosage, 425(60.45%) units used for nutritional support and hypovolaemia replacement, 131(18.63%) units for the reversal of prolonged INR in the absence of bleeding due to warfarin, 92 (13.08%) units used in ICU to correct prolonged PT without bleeding due to Vitamin K deficiency and 55(7.82%) units for chronic liver disease (CLD) to correct prolonged PT and APTT in the absence of bleeding. In summary, 1372 (66

  8. Detection of Blood Vessels in Color Fundus Images using a Local Radon Transform

    Directory of Open Access Journals (Sweden)

    Reza Pourreza

    2010-09-01

    Full Text Available Introduction: This paper addresses a method for automatic detection of blood vessels in color fundus images which utilizes two main tools: image partitioning and local Radon transform. Material and Methods: The input images are firstly divided into overlapping windows and then the Radon transform is applied to each. The maximum of the Radon transform in each window corresponds to the probable available sub-vessel. To verify the detected sub-vessel, the maximum is compared with a predefined threshold. The verified sub-vessels are reconstructed using the Radon transform information. All detected and reconstructed sub-vessels are finally combined to make the final vessel tree. Results: The algorithm’s performance was evaluated numerically by applying it to 40 images of DRIVE database, a standard retinal image database. The vessels were extracted manually by two physicians. This database was used to test and compare the available and proposed algorithms for vessel detection in color fundus images. By comparing the output of the algorithm with the manual results, the two parameters TPR and FPR were calculated for each image and the average of TPRs and FPRs were used to plot the ROC curve. Discussion and Conclusion: Comparison of the ROC curve of this algorithm with other algorithms demonstrated the high achieved accuracy. Beside the high accuracy, the Radon transform which is integral-based makes the algorithm robust against noise.

  9. A novel non-imaging optics based Raman spectroscopy device for transdermal blood analyte measurement

    Directory of Open Access Journals (Sweden)

    Chae-Ryon Kong

    2011-09-01

    Full Text Available Due to its high chemical specificity, Raman spectroscopy has been considered to be a promising technique for non-invasive disease diagnosis. However, during Raman excitation, less than one out of a million photons undergo spontaneous Raman scattering and such weakness in Raman scattered light often require highly efficient collection of Raman scattered light for the analysis of biological tissues. We present a novel non-imaging optics based portable Raman spectroscopy instrument designed for enhanced light collection. While the instrument was demonstrated on transdermal blood glucose measurement, it can also be used for detection of other clinically relevant blood analytes such as creatinine, urea and cholesterol, as well as other tissue diagnosis applications. For enhanced light collection, a non-imaging optical element called compound hyperbolic concentrator (CHC converts the wide angular range of scattered photons (numerical aperture (NA of 1.0 from the tissue into a limited range of angles accommodated by the acceptance angles of the collection system (e.g., an optical fiber with NA of 0.22. A CHC enables collimation of scattered light directions to within extremely narrow range of angles while also maintaining practical physical dimensions. Such a design allows for the development of a very efficient and compact spectroscopy system for analyzing highly scattering biological tissues. Using the CHC-based portable Raman instrument in a clinical research setting, we demonstrate successful transdermal blood glucose predictions in human subjects undergoing oral glucose tolerance tests.

  10. Fresh gasoline emissions, not paved road dust, alter cardiac repolarization in ApoE-/- mice.

    Science.gov (United States)

    Campen, Matthew J; McDonald, Jacob D; Reed, Matthew D; Seagrave, Jeanclare

    2006-01-01

    Fresh vehicular emissions potentially represent a ubiquitous environmental concern for cardiovascular health. We compared electrocardiographic effects of fresh gasoline engine emissions with resuspended paved road dust in a mouse model of coronary insufficiency. Apolipoprotein E (ApoE)-/- mice on a high fat diet were exposed by whole-body inhalation to either gasoline emissions at 60 microg/m3 particulate matter (PM), an equivalent atmosphere with particles filtered out of the whole exhaust, or paved road dust at 0.5 and 3.5 mg /m3 for 6 h/d for 3 d. Radiotelemetry recordings of electrocardiogram (ECG) were analyzed for changes in T-wave morphology (QT interval, T-wave amplitude, and T-wave Area). Following exposures, lung lavage and blood samples were obtained to assay for markers of pulmonary and systemic inflammation. No exposure induced significant changes in heart rate and only the high concentration of road dust induced signs of pulmonary inflammation. T-wave area exhibited significant deviation from baseline values during exposure to gasoline exhaust particulates, but not to either concentration of road dust or gasoline emissions sans particulates. Gasoline-exposed mice demonstrated elevated plasma endothelin-1, but did not cause systemic inflammation. These data support the hypothesis that freshly-generated engine emissions, as opposed to resuspended paved road dust, may drive cardiac effects that have been observed at road-sides in the environment. The absence of ECG effects for both very high concentrations of road dust PM and equivalent concentrations of the vapor/gas phase of gasoline engine exhaust further indicate the specific risk conferred by fresh vehicular PM.

  11. Preservation technologies for fresh meat - a review.

    Science.gov (United States)

    Zhou, G H; Xu, X L; Liu, Y

    2010-09-01

    Fresh meat is a highly perishable product due to its biological composition. Many interrelated factors influence the shelf life and freshness of meat such as holding temperature, atmospheric oxygen (O(2)), endogenous enzymes, moisture, light and most importantly, micro-organisms. With the increased demand for high quality, convenience, safety, fresh appearance and an extended shelf life in fresh meat products, alternative non-thermal preservation technologies such as high hydrostatic pressure, superchilling, natural biopreservatives and active packaging have been proposed and investigated. Whilst some of these technologies are efficient at inactivating the micro-organisms most commonly related to food-borne diseases, they are not effective against spores. To increase their efficacy against vegetative cells, a combination of several preservation technologies under the so-called hurdle concept has also been investigated. The objective of this review is to describe current methods and developing technologies for preserving fresh meat. The benefits of some new technologies and their industrial limitations is presented and discussed.

  12. Cationic liposomal drug delivery system for specific targeting of human cd14+ monocytes in whole blood

    DEFF Research Database (Denmark)

    2013-01-01

    blood when compared to adherence to granulocytes, T-lymphocytes, B- lymphocytes and/or NK cells in freshly drawn blood, to a lipid-based pharmaceutical composition comprising said liposomes and their use in monocytic associated prophylaxis, treatment or amelioration of a condition such as cancer...

  13. Red Blood Cell Agglutination for Blood Typing Within Passive Microfluidic Biochips.

    Science.gov (United States)

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2018-04-19

    Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.

  14. Continuous wave terahertz reflection imaging of human colorectal tissue

    Science.gov (United States)

    Doradla, Pallavi; Alavi, Karim; Joseph, Cecil S.; Giles, Robert H.

    2013-03-01

    Continuous wave terahertz (THz) imaging has the potential to offer a safe, non-ionizing, and nondestructive medical imaging modality for delineating colorectal cancer. Fresh excisions of normal colon tissue were obtained from surgeries performed at the University of Massachusetts Medical School, Worcester. Reflection measurements of thick sections of colorectal tissues, mounted in an aluminum sample holder, were obtained for both fresh and formalin fixed tissues. The two-dimensional reflection images were acquired by using an optically pumped far-infrared molecular gas laser operating at 584 GHz with liquid Helium cooled silicon bolometer detector. Using polarizers in the experiment both co-polarized and cross-polarized remittance form the samples was collected. Analysis of the images showed the importance of understanding the effects of formalin fixation while determining reflectance level of tissue response. The resulting co- and cross-polarized images of both normal and formalin fixed tissues showed uniform terahertz response over the entire sample area. Initial measurements indicated a co-polarized reflectance of 16%, and a cross-polarized reflectance of 0.55% from fresh excisions of normal colonic tissues.

  15. Real-time imaging of subarachnoid hemorrhage in piglets with electrical impedance tomography.

    Science.gov (United States)

    Dai, Meng; Wang, Liang; Xu, Canhua; Li, Lianfeng; Gao, Guodong; Dong, Xiuzhen

    2010-09-01

    Subarachnoid hemorrhage (SAH) is one of the most severe medical emergencies in neurosurgery. Early detection or diagnosis would significantly reduce the rate of disability and mortality, and improve the prognosis of the patients. Although the present medical imaging techniques generally have high sensitivity to identify bleeding, the use of an additional, non-invasive imaging technique capable of continuously monitoring SAH is required to prevent contingent bleeding or re-bleeding. In this study, electrical impedance tomography (EIT) was applied to detect the onset of SAH modeled on eight piglets in real time, with the subsequent process being monitored continuously. The experimental SAH model was introduced by one-time injection of 5 ml fresh autologous arterial blood into the cisterna magna. Results showed that resistivity variations within the brain caused by the added blood could be detected using the EIT method and may be associated not only with the resistivity difference among brain tissues, but also with variations of cerebrospinal fluid dynamics. In conclusion, EIT has unique potential for use in clinical practice to provide invaluable real-time neuroimaging data for SAH after the improvement of electrode design, anisotropic realistic modeling and instrumentation.

  16. Chitosan-glycerol phosphate/blood implants improve hyaline cartilage repair in ovine microfracture defects.

    Science.gov (United States)

    Hoemann, Caroline D; Hurtig, Mark; Rossomacha, Evgeny; Sun, Jun; Chevrier, Anik; Shive, Matthew S; Buschmann, Michael D

    2005-12-01

    Microfracture is a surgical procedure that is used to treat focal articular cartilage defects. Although joint function improves following microfracture, the procedure elicits incomplete repair. As blood clot formation in the microfracture defect is an essential initiating event in microfracture therapy, we hypothesized that the repair would be improved if the microfracture defect were filled with a blood clot that was stabilized by the incorporation of a thrombogenic and adhesive polymer, specifically, chitosan. The objectives of the present study were to evaluate (1) blood clot adhesion in fresh microfracture defects and (2) the quality of the repair, at six months postoperatively, of microfracture defects that had been treated with or without chitosan-glycerol phosphate/blood clot implants, using a sheep model. In eighteen sheep, two 1-cm2 full-thickness chondral defects were created in the distal part of the femur and treated with microfracture; one defect was made in the medial femoral condyle, and the other defect was made in the trochlea. In four sheep, microfracture defects were created bilaterally; the microfracture defects in one knee received no further treatment, and the microfracture defects in the contralateral knee were filled with chitosan-glycerol phosphate/autologous whole blood and the implants were allowed to solidify. Fresh defects in these four sheep were collected at one hour postoperatively to compare the retention of the chitosan-glycerol phosphate/blood clot with that of the normal clot and to define the histologic characteristics of these fresh defects. In the other fourteen sheep, microfracture defects were made in only one knee and either were left untreated (control group; six sheep) or were treated with chitosan-glycerol phosphate/blood implant (treatment group; eight sheep), and the quality of repair was assessed histologically, histomorphometrically, and biochemically at six months postoperatively. In the defects that were examined

  17. Electron beam processing of fresh produce - A critical review

    Science.gov (United States)

    Pillai, Suresh D.; Shayanfar, Shima

    2018-02-01

    To meet the increasing global demand for fresh produce, robust processing methods that ensures both the safety and quality of fresh produce are needed. Since fresh produce cannot withstand thermal processing conditions, most of common safety interventions used in other foods are ineffective. Electron beam (eBeam) is a non-thermal technology that can be used to extend the shelf life and ensure the microbiological safety of fresh produce. There have been studies documenting the application of eBeam to ensure both safety and quality in fresh produce, however, there are still unexplored areas that still need further research. This is a critical review on the current literature on the application of eBeam technology for fresh produce.

  18. 77 FR 26579 - Fresh Garlic From China; Determination

    Science.gov (United States)

    2012-05-04

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-683 (Third Review)] Fresh Garlic From... Tariff Act of 1930 (19 U.S.C. 1675(c)), that revocation of the antidumping duty order on fresh garlic... contained in USITC Publication 4316 (April 2012), entitled Fresh Garlic from China: Investigation No. 731-TA...

  19. Methods to evaluate fish freshness in research and industry

    DEFF Research Database (Denmark)

    Olafsdottir, G.; Martinsdóttir, E.; Oehlenschläger, J.

    1997-01-01

    Current work in a European concerted action project 'Evaluation of Fish Freshness' (AIR3 CT94-2283) focuses on harmonizing research activities in the area of fish freshness evaluation in leading fish laboratories in Europe (see Box 1). The overall aim of the concerted action project is to validat...... measurements with respect to fish freshness evaluation. In this article, the different subgroups have summarized changes that occur in fish and methods to evaluate fish freshness as a first step towards the definition of criteria for fish freshness...

  20. Use of gamma-irradiated blood for feeding tsetse flies

    International Nuclear Information System (INIS)

    Bauer, B.; Iwannek, K.H.; Hamann, H.J.; Adamsky, G.

    1980-01-01

    Freshly collected pig blood was sterilized by 60 Co gamma irradiation. A dose of 100 krad proved to be effective against Pseudomonas aeruginosa at concentrations of at least 4.7x10 5 /ml. Glossina morsitans morsitans (Westw.) were maintained on this blood by feeding them five days per week on silicone membrane for nine months. Their performance was compared with a control fed untreated blood. In spite of the slightly faster haemolysis of the irradiated blood, the results from the experimental group compared favourably with the control. This was especially true for the percentage of daily mortality. The irradiation seems to offer a promising approach for the establishment of mass rearing plants in Africa based on in vitro feeding provided the blood from donor animals is suitable for tsetse flies. (author)

  1. Comparison of the image-derived radioactivity and blood-sample radioactivity for estimating the clinical indicators of the efficacy of boron neutron capture therapy (BNCT): 4-borono-2-18F-fluoro-phenylalanine (FBPA) PET study.

    Science.gov (United States)

    Isohashi, Kayako; Shimosegawa, Eku; Naka, Sadahiro; Kanai, Yasukazu; Horitsugi, Genki; Mochida, Ikuko; Matsunaga, Keiko; Watabe, Tadashi; Kato, Hiroki; Tatsumi, Mitsuaki; Hatazawa, Jun

    2016-12-01

    In boron neutron capture therapy (BNCT), positron emission tomography (PET) with 4-borono-2- 18 F-fluoro-phenylalanine (FBPA) is the only method to estimate an accumulation of 10 B to target tumor and surrounding normal tissue after administering 10 B carrier of L-paraboronophenylalanine and to search the indication of BNCT for individual patient. Absolute concentration of 10 B in tumor has been estimated by multiplying 10 B concentration in blood during BNCT by tumor to blood radioactivity (T/B) ratio derived from FBPA PET. However, the method to measure blood radioactivity either by blood sampling or image data has not been standardized. We compared image-derived blood radioactivity of FBPA with blood sampling data and studied appropriate timing and location for measuring image-derived blood counts. We obtained 7 repeated whole-body PET scans in five healthy subjects. Arterialized venous blood samples were obtained from the antecubital vein, heated in a heating blanket. Time-activity curves (TACs) of image-derived blood radioactivity were obtained using volumes of interest (VOIs) over ascending aorta, aortic arch, pulmonary artery, left and right ventricles, inferior vena cava, and abdominal aorta. Image-derived blood radioactivity was compared with those measured by blood sampling data in each location. Both the TACs of blood sampling radioactivity in each subject, and the TACs of image-derived blood radioactivity showed a peak within 5 min after the tracer injection, and promptly decreased soon thereafter. Linear relationship was found between blood sampling radioactivity and image-derived blood radioactivity in all the VOIs at any timing of data sampling (p radioactivity measured in the left and right ventricles 30 min after injection showed high correlation with blood radioactivity. Image-derived blood radioactivity was lower than blood sampling radioactivity data by 20 %. Reduction of blood radioactivity of FBPA in left ventricle after 30 min of FBPA

  2. An integrated 3-D image of cerebral blood vessels and CT view of tumor

    International Nuclear Information System (INIS)

    Suetens, P.; Baert, A.L.; Gybels, J.; Haegemans, S.; Jansen, P.; Oosterlinck, A.; Wilms, G.

    1984-01-01

    The authors developed a method that yields an integrated three-dimensional image of cerebral blood vessels and CT view of tumor. This method allows the neurosurgeon to choose any electrode trajectory that looks convenient to him, without imminent danger of causing a hemorrhage. Besides offering more safety to stereotactic interventions, this integrated 3-D image also has other applications. First, it gives a better characterization of most focal mass lesions seen by CT. Second, it allows high dose focal irradiation to be effected in such a way as to avoid arteries and veins. Third, it provides useful information for planning the strategy of open surgery

  3. Fresh fruit: microstructure, texture and quality

    Science.gov (United States)

    Fresh-cut produce has a huge following in today’s supermarkets. The trend follows the need to decrease preparation time as well as the desire to follow the current health guidelines for consumption of more whole “heart-healthy” foods. Additionally, consumers are able to enjoy a variety of fresh prod...

  4. The effects of transfusion of irradiated blood upon cellular immune response in patients underwent open heart surgery

    International Nuclear Information System (INIS)

    Togashi, Ken-ichi; Nakazawa, Satoshi; Moro, Hisanaga; Yazawa, Masatomo; Kanazawa, Hiroshi; Hayashi, Jun-ichi; Yamazaki, Yoshihiko; Eguchi, Shoji

    1989-01-01

    The purpose of this paper is to demonstrate the effect of the transfusion of blood received 1500 rad exposure upon the immune response in 14 patients underwent various type of cardiac surgery. 13 patients received known amounts banked blood and irradiated fresh blood, while one patient received a lot of amounts of banked and irradiated and non-irradiated fresh blood. The authors studied the numbers of lymphocytes as well as lymphocyte subsets such as pan-T cells, B cells, helper/inducer T cells (T H/I ), cytotoxic/supressor T cells (T C/S ), active T cells, natural killer (NK) cells and NK cell activity during two weeks after surgeries. In all 14 patients, pan-T lymphocytes decreased markedly in a few days after surgeries, but increased to higher levels on the eight postoperative day than the levels preoperatively. T H/I and T C/S lymphocytes changed on the similar pattern as pan-T lymphocytes. Active T and B cells did not change significantly in two weeks. The number and activity of NK cells gave the lowest levels on the second postoperative day and did not recovery to the preoperative levels in two weeks. One patient received non-irradiated fresh blood showed the similar immune response as other 13 patients, while he gave the lower levels than others did. This patient died of graft-versus-host disease (GVHD)-like syndrome on the 36th postoperative day. It may be thought that the transfusion of irradiated blood would prevent the host from GVHD and gave the better effects on the immune response than that of non-irradiated blood following open-heart surgeries. (author)

  5. A NIR-BODIPY derivative for sensing copper(II) in blood and mitochondrial imaging

    Science.gov (United States)

    He, Shao-Jun; Xie, Yu-Wen; Chen, Qiu-Yun

    2018-04-01

    In order to develop NIR BODIPY for mitochondria targeting imaging agents and metal sensors, a side chain modified BODIPY (BPN) was synthesized and spectroscopically characterized. BPN has NIR emission at 765 nm when excited at 704 nm. The emission at 765 nm responded differently to Cu2+ and Mn2+ ions, respectively. The BPN coordinated with Cu2+ forming [BPNCu]2+ complex with quenched emission, while Mn2+ induced aggregation of BPN with specific fluorescence enhancement. Moreover, BPN can be applied to monitor Cu2+ in live cells and image mitochondria. Further, BPN was used as sensor for the detection of Cu2+ ions in serum with linear detection range of 0.45 μM-36.30 μM. Results indicate that BPN is a good sensor for the detection of Cu2+ in serum and image mitochondria. This study gives strategies for future design of NIR sensors for the analysis of metal ions in blood.

  6. Low-dose myocardial blood flow imaging using 82Rb-PET (RUBILOW 2.0)

    DEFF Research Database (Denmark)

    Hoff, Camilla Molich; Tolbod, Lars Poulsen; Harms, Hans

    2017-01-01

    Aim: Relative and absolute measures of myocardial blood flow (MBF) can be derived from a 82Rb PET/CT scan using list mode data to extract static, gated and dynamic PET series. High doses of 82Rb are used to maximize image quality in especially static images. High doses require large eluate volumes......, may degrade scanner dead time performance at first pass and decreases generator lifetime. Lower doses will expand the availability of 82Rb PET/CT and lower doses to personnel and patients. The aim of the current study was to examine MBF with a low dose (LD) 82Rb protocol compared to the institution......’s standard (STD) protocol. Methods: Twenty-one patients referred to 82Rb PET were included in the study. Patients were examined during rest and stress with repeated LD (740 MBq) and STD dose (1110 MBq) Rb-PET during the same imaging session. Regional and global rest and stress MBF values, total perfusion...

  7. Effects of high-fat diet and losartan on renal cortical blood flow using contrast ultrasound imaging.

    Science.gov (United States)

    Declèves, Anne-Emilie; Rychak, Joshua J; Smith, Dan J; Sharma, Kumar

    2013-11-01

    Obesity-related kidney disease occurs as a result of complex interactions between metabolic and hemodynamic effects. Changes in microvascular perfusion may play a major role in kidney disease; however, these changes are difficult to assess in vivo. Here, we used perfusion ultrasound imaging to evaluate cortical blood flow in a mouse model of high-fat diet-induced kidney disease. C57BL/6J mice were randomized to a standard diet (STD) or a high-fat diet (HFD) for 30 wk and then treated either with losartan or a placebo for an additional 6 wk. Noninvasive ultrasound perfusion imaging of the kidney was performed during infusion of a microbubble contrast agent. Blood flow within the microvasculature of the renal cortex and medulla was derived from imaging data. An increase in the time required to achieve full cortical perfusion was observed for HFD mice relative to STD. This was reversed following treatment with losartan. These data were concurrent with an increased glomerular filtration rate in HFD mice compared with STD- or HFD-losartan-treated mice. Losartan treatment also abrogated fibro-inflammatory disease, assessed by markers at the protein and messenger level. Finally, a reduction in capillary density was found in HFD mice, and this was reversed upon losartan treatment. This suggests that alterations in vascular density may be responsible for the elevated perfusion time observed by imaging. These data demonstrate that ultrasound contrast imaging is a robust and sensitive method for evaluating changes in renal microvascular perfusion and that cortical perfusion time may be a useful parameter for evaluating obesity-related renal disease.

  8. Imaging of Neuronal Activity in Awake Mice by Measurements of Flavoprotein Autofluorescence Corrected for Cerebral Blood Flow.

    Science.gov (United States)

    Takahashi, Manami; Urushihata, Takuya; Takuwa, Hiroyuki; Sakata, Kazumi; Takado, Yuhei; Shimizu, Eiji; Suhara, Tetsuya; Higuchi, Makoto; Ito, Hiroshi

    2017-01-01

    Green fluorescence imaging (e.g., flavoprotein autofluorescence imaging, FAI) can be used to measure neuronal activity and oxygen metabolism in living brains without expressing fluorescence proteins. It is useful for understanding the mechanism of various brain functions and their abnormalities in age-related brain diseases. However, hemoglobin in cerebral blood vessels absorbs green fluorescence, hampering accurate assessments of brain function in animal models with cerebral blood vessel dysfunctions and subsequent cerebral blood flow (CBF) alterations. In the present study, we developed a new method to correct FAI signals for hemoglobin-dependent green fluorescence reductions by simultaneous measurements of green fluorescence and intrinsic optical signals. Intrinsic optical imaging enabled evaluations of light absorption and scatters by hemoglobin, which could then be applied to corrections of green fluorescence intensities. Using this method, enhanced flavoprotein autofluorescence by sensory stimuli was successfully detected in the brains of awake mice, despite increases of CBF, and hemoglobin interference. Moreover, flavoprotein autofluorescence could be properly quantified in a resting state and during sensory stimulation by a CO 2 inhalation challenge, which modified vascular responses without overtly affecting neuronal activities. The flavoprotein autofluorescence signal data obtained here were in good agreement with the previous findings from a condition with drug-induced blockade of cerebral vasodilation, justifying the current assaying methodology. Application of this technology to studies on animal models of brain diseases with possible changes of CBF, including age-related neurological disorders, would provide better understanding of the mechanisms of neurovascular coupling in pathological circumstances.

  9. The preliminary study of the blood perfusion and ammonia metabolism of pituitary using dynamic 13N-NH3 PET imaging

    International Nuclear Information System (INIS)

    Zhang Xiangsong; Tang Anwu; Qiao Suixian; Chen Liguang; Luo Yaowu; Liu Bin; Xu Weiping

    2002-01-01

    Objective: To preliminarily study the blood perfusion and ammonia metabolism of pituitary using dynamic 13 N-NH 3 PET imaging. Methods: 13 N-NH 3 PET imaging was performed on 21 subjects without pituitary diseases, 6 of them underwent dynamic PET imaging, and 8 of them underwent brain MRI in addition to PET. PET images were registered with MRI. Results: The pituitary could be clearly seen in 13 N-NH 3 PET images, and being confirmed by PET/MRI image fusion. The size of pituitary was (1.07 +- 0.17) cm x (1.09 +- 0.15) cm x (1.14 +- 0.17) cm, the standard uptake value (SUV) was 3.84 +- 1.75, and the radioactivity ratio of pituitary to thalamus was 1.35 +- 0.63. Pituitary image was seen at 10 s after the internal carotid was seen in dynamic 13 N-NH 3 PET imaging. 13 N-NH 3 was retained in pituitary, and was hardly cleaned out within 20 min. The radioactivity ratio of pituitary to internal carotid was 0.75 +- 0.13 when the radioactivity of internal carotid was at its highest level. Conclusions: The blood flow and ammonia metabolism of pituitary can be observed with dynamic 13 N-NH 3 PET imaging. Ammonia is highly extracted by pituitary, and metabolized in pituitary cells

  10. Red blood cells intended for transfusion : quality criteria revisited

    NARCIS (Netherlands)

    Hogman, CF; Meryman, HT

    Great variation exists with respect to viability and function of fresh and stored red blood cells (RBCs) as well as of the contents of RBC hemoglobin (Hb) in individual units. Improved technology is available for the preparation as well as the storage of RBCs. The authors raise the question whether

  11. ACE blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003567.htm ACE blood test To use the sharing features on this page, ... Alternative Names Serum angiotensin-converting enzyme; SACE Images Blood test References Carty RP, Pincus MR, Sarafraz-Yazdi E. ...

  12. Aldolase blood test

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003566.htm Aldolase blood test To use the sharing features on this page, ... risk any time the skin is broken) Images Blood test References Berridge BR, Van Vleet JF, Herman E. ...

  13. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    Science.gov (United States)

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (pcadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical

  14. Freshness indices of roasted coffee: monitoring the loss of freshness for single serve capsules and roasted whole beans in different packaging.

    Science.gov (United States)

    Glöss, Alexia N; Schönbächler, Barbara; Rast, Markus; Deuber, Louis; Yeretzian, Chahan

    2014-01-01

    With the growing demand for high-quality coffee, it is becoming increasingly important to establish quantitative measures of the freshness of coffee, or the loss thereof, over time. Indeed, freshness has become a critical quality criterion in the specialty coffee scene, where the aim is to deliver the most pleasant flavor in the cup, from highest quality beans. A series of intensity ratios of selected volatile organic compounds (VOC) in the headspace of coffee (by gas chromatography-mass spectrometry) were revisited, with the aim to establish robust indicators of freshness of coffee - called freshness indices. Roasted whole beans in four different packaging materials and four commercial capsule systems from the Swiss market were investigated over a period of up to one year of storage time. These measurements revealed three types of insight. First, a clear link between barrier properties of the packaging material and the evolution of selected freshness indices was observed. Packaging materials that contain an aluminum layer offer better protection. Second, processing steps prior to packaging are reflected in the absolute values of freshness indices. Third, differences in the standard deviations of freshness-indices for single serve coffee capsule systems are indicative of differences in the consistency among systems, consistency being an important quality attribute of capsules.

  15. Effects of oxidised oil and vitamin E on performance and some blood ...

    African Journals Online (AJOL)

    oxidised dietary oil and vitamin E supplementation could be determined on the performance, lipid peroxidation, antioxidant defence system and some blood and meat quality traits of broilers. Broilers were fed grower diets containing fresh or oxidised ...

  16. Magnetic resonance imaging-guided focused ultrasound to increase localized blood-spinal cord barrier permeability.

    Science.gov (United States)

    Payne, Allison H; Hawryluk, Gregory W; Anzai, Yoshimi; Odéen, Henrik; Ostlie, Megan A; Reichert, Ethan C; Stump, Amanda J; Minoshima, Satoshi; Cross, Donna J

    2017-12-01

    Spinal cord injury (SCI) affects thousands of people every year in the USA, and most patients are left with some permanent paralysis. Therapeutic options are limited and only modestly affect outcome. To address this issue, we used magnetic resonance imaging-guided focused ultrasound (MRgFUS) as a non-invasive approach to increase permeability in the blood-spinal cord barrier (BSCB). We hypothesize that localized, controlled sonoporation of the BSCB by MRgFUS will aid delivery of therapeutics to the injury. Here, we report our preliminary findings for the ability of MRgFUS to increase BSCB permeability in the thoracic spinal cord of a normal rat model. First, an excised portion of normal rat spinal column was used to characterize the acoustic field and to estimate the insertion losses that could be expected in an MRgFUS blood spinal cord barrier opening. Then, in normal rats, MRgFUS was applied in combination with intravenously administered microbubbles to the spinal cord region. Permeability of the BSCB was indicated as signal enhancement by contrast administered prior to T1-weighted magnetic resonance imaging and verified by Evans blue dye. Neurological testing using the Basso, Beattie, and Breshnahan scale and the ladder walk was normal in 8 of 10 rats tested. Two rats showed minor impairment indicating need for further refinement of parameters. No gross tissue damage was evident by histology. In this study, we have opened successfully the blood spinal cord barrier in the thoracic region of the normal rat spine using magnetic resonance-guided focused ultrasound combined with microbubbles.

  17. Waste Reduction in Fresh Food Supply Chains

    DEFF Research Database (Denmark)

    Kaipia, Riikka; Loikkanen, Lauri; Dukovska-Popovska, Iskra

    2011-01-01

    The paper studies a well-known phenomenon, information sharing in supply chains, in a new context, fresh foods, with a specific goal, supporting sustainable performance in the supply chain. Fresh foods are important for retail stores, representing around half of retail sales, but form a challengi...... and heterogeneous group of products to manage. The value of the paper lies in its pointing out detailed solutions to how in real-life supply chains data can be used efficiently to improve the performance of the supply chain.......The paper studies a well-known phenomenon, information sharing in supply chains, in a new context, fresh foods, with a specific goal, supporting sustainable performance in the supply chain. Fresh foods are important for retail stores, representing around half of retail sales, but form a challenging...

  18. The prevalence of toxoplasmosis in Imam Reza Hospital blood bank samples, Tehran, Iran.

    Science.gov (United States)

    Shaddel, M; Mirzaii Dizgah, I; Sharif, F

    2014-10-01

    The prevalence of toxoplasma gondii (T.g) infection in blood donors has been poorly studied. The aim of this study was to assess the prevalence of acute and chronic toxoplasmosis in blood products. A total of 223 blood products (101 fresh frozen plasma (FFP) and 122 packed cells (PC)) in Imam Reza hospital blood bank, Tehran, Iran were tested for specific T.g antibodies (IgG and IgM) by ELISA method. Positive IgG anti-T.g samples were further tested for IgM anti-T.g. A positive IgG test with the negative and positive IgM test was interpreted as a chronic and acute toxoplasmosis respectively. Of 223 samples 38.6% and 0.45% were positive for IgG anti-T.g and IgM anti-T.g levels respectively. Therefore, one and 85 samples were involved acute and chronic toxoplasmosis respectively. Twenty-six of fresh frozen plasma samples were positive for IgG anti-T.g and one of them was positive for IgM anti-T.g. Sixty packed cell samples were positive for IgG anti-T.g. Our study showed that there were chronic and acute toxoplasmosis in blood products and the prevalence of toxoplasmosis especially chronic form was high. Therefore screening of blood for T.g antibodies may be considered. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Color capable sub-pixel resolving optofluidic microscope and its application to blood cell imaging for malaria diagnosis.

    Directory of Open Access Journals (Sweden)

    Seung Ah Lee

    Full Text Available Miniaturization of imaging systems can significantly benefit clinical diagnosis in challenging environments, where access to physicians and good equipment can be limited. Sub-pixel resolving optofluidic microscope (SROFM offers high-resolution imaging in the form of an on-chip device, with the combination of microfluidics and inexpensive CMOS image sensors. In this work, we report on the implementation of color SROFM prototypes with a demonstrated optical resolution of 0.66 µm at their highest acuity. We applied the prototypes to perform color imaging of red blood cells (RBCs infected with Plasmodium falciparum, a particularly harmful type of malaria parasites and one of the major causes of death in the developing world.

  20. Impact of a blood-sucking parasite on the chemical composition of ...

    African Journals Online (AJOL)

    Lenovo

    2013-10-30

    Oct 30, 2013 ... Key words: Garfish, blood-sucking, parasite, parasitized fish, fatty acid analysis, Tunisia. .... to March, in the Black Sea, 5 g/100 g (fresh muscle) ..... petits pélagiques du golfe du Lion 10éme Forum halieumétrique, juin-.

  1. Vertigo-related cerebral blood flow changes on magnetic resonance imaging.

    Science.gov (United States)

    Chang, Feiyan; Li, Zhongshi; Xie, Sheng; Liu, Hui; Wang, Wu

    2014-11-01

    A prospective study using magnetic resonance imaging on a consecutive cohort of patients with cervical vertigo. To quantitatively investigate the cerebral blood flow (CBF) changes associated with cervical vertigo by using 3-dimensional pseudocontinuous arterial spin labeling. Previous studies reported blood flow velocity reduction in posterior circulation during vertigo. However, the detailed information of CBF related to cervical vertigo has not been provided. A total of 33 patients with cervical vertigo and 14 healthy volunteers were recruited in this study. Three-dimensional pseudocontinuous arterial spin labeling was performed on each subject to evaluate the CBF before and after the cervical hyperextension-hyperflexion movement tests, which was used to induce cervical vertigo. Repeated-measures analysis of variance was conducted to assess the effect of subjects and tests. There were time effects of CBF in the territory of bilateral superior cerebellar artery, bilateral posterior cerebral artery, bilateral middle cerebral artery, and right anterior cerebral artery, but no group effect was observed. The analysis of CBF revealed a significant main effect of tests (P=0.024) and participants (P=0.038) in the dorsal pons. Cervical vertigo onset may be related to CBF reduction in the dorsal pons, which sequentially evokes the vestibular nuclei. 2.

  2. An incubation medium for the elevation of adenosine triphosphate and 2,3-diphosphoglycerate in fresh and long-preserved human erythrocytes.

    Science.gov (United States)

    Rubinstein, D; Warrendorf, E

    1975-06-01

    The levels of adenosine triphosphate (ATP) and 2,3-diphosphoglycerate in freshly drawn human erythrocytes can be tripled by a 2 h incubation at 37 degrees C in a medium containing 21 mM glucose, 1.8 mM adenine, 5 mM pyruvate, 10 mM inosine, and 96 mM phosphate. Similar incubation conditions will restore the levels of ATP and 2,3-diphosphoglycerate in erythrocytes from blood levels preserved for 12 and 15 weeks, respectively, to those of fresh cells. Omission of pyruvate from the incubation medium further increases the level of ATP slightly, but there is little elevation of 2,3-diphosphoglycerate. Under these conditions labelled pyruvate and lactate production from [14-C]glucose or [14-C]inosine is not diminished, but labelled fructose 1,6-diphosphate, rather than 2,3-diphosphoglycerate, accumulates. In addition, omission of pyruvate from the incubation medium, with a concomitant decrease in accumulation of 2,3-diphosphoglycerate, diminishes the concentration of inorganic phosphate required for optimal ATP elevation. A 5 h incubation in the glucose-adenine-pyruvate-inosine-phosphate medium elevates the levels of ATP and 2,3-diphosphoglycerate in erythrocytes from blood preserved in the cold for 15 weeks to twice that of fresh cells, indicating that the cells retain their metabolic potential even after prolonged storage at 2 degrees C. The medium may provide a method of rejuvenating 10-12 week cold-preserved erythrocytes for transfusion purposes, by a 1 h incubation at 37 degrees C.

  3. Methods of Blood Oxygen Level-Dependent Magnetic Resonance Imaging Analysis for Evaluating Renal Oxygenation

    Directory of Open Access Journals (Sweden)

    Fen Chen

    2018-03-01

    Full Text Available Blood oxygen level-dependent magnetic resonance imaging (BOLD MRI has recently been utilized as a noninvasive tool for evaluating renal oxygenation. Several methods have been proposed for analyzing BOLD images. Regional ROI selection is the earliest and most widely used method for BOLD analysis. In the last 20 years, many investigators have used this method to evaluate cortical and medullary oxygenation in patients with ischemic nephropathy, hypertensive nephropathy, diabetic nephropathy, chronic kidney disease (CKD, acute kidney injury and renal allograft rejection. However, clinical trials of BOLD MRI using regional ROI selection revealed that it was difficult to distinguish the renal cortico-medullary zones with this method, and that it was susceptible to observer variability. To overcome these deficiencies, several new methods were proposed for analyzing BOLD images, including the compartmental approach, fractional hypoxia method, concentric objects (CO method and twelve-layer concentric objects (TLCO method. The compartmental approach provides an algorithm to judge whether the pixel belongs to the cortex or medulla. Fractional kidney hypoxia, measured by using BOLD MRI, was negatively correlated with renal blood flow, tissue perfusion and glomerular filtration rate (GFR in patients with atherosclerotic renal artery stenosis. The CO method divides the renal parenchyma into six or twelve layers of thickness in each coronal slice of BOLD images and provides a R2* radial profile curve. The slope of the R2* curve associated positively with eGFR in CKD patients. Indeed, each method invariably has advantages and disadvantages, and there is generally no consensus method so far. Undoubtedly, analytic approaches for BOLD MRI with better reproducibility would assist clinicians in monitoring the degree of kidney hypoxia and thus facilitating timely reversal of tissue hypoxia.

  4. Detecting early cardiac dysfunction with radionuclide cardiac blood-pool imaging

    International Nuclear Information System (INIS)

    Wu Kegui; Chen Daguang; Lin Haoxue

    1992-01-01

    Cardiac function was measured by radionuclide cardiac blood-pool imaging in 15 normal persons, 19 cases of hypertension, 32 cases of coronary heart disease, 35 cases of coronary heart disease combined with hypertension and 44 cases of myocardial infarction. Significant differences have been found in indices of cardiac function between normal subjects and patients with coronary heart disease and coronary heart disease combined with hypertension, even though the patients were without any clinical sin of cardiac failure. Lowered regional EF and decreased ventricular was motion were found in 38.8% of patients, while 65.7%of patients revealed marked abnormality in MFR. The results indicate that latent cardiac dysfunction is common in patients with coronary heart disease. The earliest change is diastolic function abnormalities

  5. Establishing the Global Fresh Water Sensor Web

    Science.gov (United States)

    Hildebrand, Peter H.

    2005-01-01

    This paper presents an approach to measuring the major components of the water cycle from space using the concept of a sensor-web of satellites that are linked to a data assimilation system. This topic is of increasing importance, due to the need for fresh water to support the growing human population, coupled with climate variability and change. The net effect is that water is an increasingly valuable commodity. The distribution of fresh water is highly uneven over the Earth, with both strong latitudinal distributions due to the atmospheric general circulation, and even larger variability due to landforms and the interaction of land with global weather systems. The annual global fresh water budget is largely a balance between evaporation, atmospheric transport, precipitation and runoff. Although the available volume of fresh water on land is small, the short residence time of water in these fresh water reservoirs causes the flux of fresh water - through evaporation, atmospheric transport, precipitation and runoff - to be large. With a total atmospheric water store of approx. 13 x 10(exp 12)cu m, and an annual flux of approx. 460 x 10(exp 12)cu m/y, the mean atmospheric residence time of water is approx. 10 days. River residence times are similar, biological are approx. 1 week, soil moisture is approx. 2 months, and lakes and aquifers are highly variable, extending from weeks to years. The hypothesized potential for redistribution and acceleration of the global hydrological cycle is therefore of concern. This hypothesized speed-up - thought to be associated with global warming - adds to the pressure placed upon water resources by the burgeoning human population, the variability of weather and climate, and concerns about anthropogenic impacts on global fresh water availability.

  6. Evaluation of the overnight hold of whole blood at room temperature, before component processing: platelets (PLTs) from PLT-rich plasma.

    Science.gov (United States)

    van der Meer, Pieter F; Cancelas, Jose A; Vassallo, Ralph R; Rugg, Neeta; Einarson, Mindy; Hess, John R

    2011-01-01

    Whole blood (WB) must be refrigerated within 8 hours to optimize Factor VIII: C yield, but chilled platelets (PLTs) are rapidly removed from circulation and cannot be used clinically. It is logistically preferable to hold WB overnight at room temperature for next-day processing. We compared in vitro quality of PLT-rich plasma (PRP)-derived PLT concentrates (PCs) from fresh versus overnight-held WB. Four units of WB were pooled and split to prevent donor-dependent differences. One unit was processed immediately; three others were held at room temperature and processed after 24 to 26 hours. After soft-spin centrifugation, PRP was separated from the red blood cells. PRP was hard-spun to make PLT-poor plasma, and the PLTs were resuspended in approximately 60 mL of plasma and stored for 7 days (n = 8 paired experiments by two blood centers). After overnight hold, the PLT concentration was 1.37 × 10(9) ± 0.19 × 10(9) /mL versus 1.03 × 10(9) ± 0.32 × 10(9) /mL for freshly prepared PCs (p < 0.05). pH and glucose were significantly lower and lactate higher for overnight-held units on Day 1, but by Day 5, the differences had disappeared. Hypotonic shock response was initially better, 73 ± 14% for overnight-held versus 53 ± 12% for freshly processed (p < 0.001), but this difference also disappeared during storage. Activation marker CD62P was not different. In vitro storage conditions produce immediate differences after preparation, which disappear throughout storage. PCs from overnight-held WB have similar in vitro variables as from freshly processed WB. These findings warrant confirmation in clinical trials, but underscore the possibility of use of these PCs as being equivalent to those obtained from freshly processed WB. © 2010 American Association of Blood Banks.

  7. SU-G-IeP1-07: Inaccuracy of Lesion Blood Flow Quantification Related to the Proton Density Reference Image in Arterial Spin Labeling MRI of Brain Tumors

    International Nuclear Information System (INIS)

    Jen, M; Johnson, J; Hou, P; Liu, H

    2016-01-01

    Purpose: Cerebral blood flow quantification in arterial spin labeling (ASL) MRI requires an estimate of the equilibrium magnetization of blood, which is often obtained by a set of proton density (PD) reference image. Normally, a constant blood-brain partition coefficient is assumed across the brain. However, this assumption may not be valid for brain lesions. This study aimed to evaluate the impact of lesion-related PD variations on ASL quantification in patients with brain tumors. Methods: MR images for posttreatment evaluation of 42 patients with brain tumors were retrospectively analyzed. These images were acquired on a 3T MRI scanner, including T2-weighted FLAIR, 3D pseudo-continuous ASL and post-contrast T1-weighted images. Anatomical images were coregistered with ASL images using the SPM software. Regions of interest (ROIs) of the enhancing and FLAIR lesions were manually drawn on the coregistered images. ROIs of the contralateral normal appearing tissues were also determined, with the consideration of approximating coil sensitivity patterns in lesion ROIs. Relative lesion blood flow (lesion/contralateral tissue) was calculated from both the CBF map (dependent on the PD) and the ΔM map for comparison. Results: The signal intensities in both enhancing and FLAIR lesions were significantly different than contralateral tissues on the PD reference image (p<0.001). The percent signal difference ranged from −15.9 to 19.2%, with a mean of 5.4% for the enhancing lesion, and from −2.8 to 22.9% with a mean of 10.1% for the FLAIR lesion. The high/low lesion-related PD signal resulted in inversely proportional under-/over-estimation of blood flow in both enhancing and FLAIR lesions. Conclusion: Significant signal differences were found between lesions and contralateral tissues in the PD reference image, which introduced errors in blood flow quantification in ASL. The error can be up to 20% in individual patients with an average of 5- 10% for the group of patients

  8. SU-G-IeP1-07: Inaccuracy of Lesion Blood Flow Quantification Related to the Proton Density Reference Image in Arterial Spin Labeling MRI of Brain Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Jen, M; Johnson, J; Hou, P; Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: Cerebral blood flow quantification in arterial spin labeling (ASL) MRI requires an estimate of the equilibrium magnetization of blood, which is often obtained by a set of proton density (PD) reference image. Normally, a constant blood-brain partition coefficient is assumed across the brain. However, this assumption may not be valid for brain lesions. This study aimed to evaluate the impact of lesion-related PD variations on ASL quantification in patients with brain tumors. Methods: MR images for posttreatment evaluation of 42 patients with brain tumors were retrospectively analyzed. These images were acquired on a 3T MRI scanner, including T2-weighted FLAIR, 3D pseudo-continuous ASL and post-contrast T1-weighted images. Anatomical images were coregistered with ASL images using the SPM software. Regions of interest (ROIs) of the enhancing and FLAIR lesions were manually drawn on the coregistered images. ROIs of the contralateral normal appearing tissues were also determined, with the consideration of approximating coil sensitivity patterns in lesion ROIs. Relative lesion blood flow (lesion/contralateral tissue) was calculated from both the CBF map (dependent on the PD) and the ΔM map for comparison. Results: The signal intensities in both enhancing and FLAIR lesions were significantly different than contralateral tissues on the PD reference image (p<0.001). The percent signal difference ranged from −15.9 to 19.2%, with a mean of 5.4% for the enhancing lesion, and from −2.8 to 22.9% with a mean of 10.1% for the FLAIR lesion. The high/low lesion-related PD signal resulted in inversely proportional under-/over-estimation of blood flow in both enhancing and FLAIR lesions. Conclusion: Significant signal differences were found between lesions and contralateral tissues in the PD reference image, which introduced errors in blood flow quantification in ASL. The error can be up to 20% in individual patients with an average of 5- 10% for the group of patients

  9. Study on storage efficiency of the fresh food e-commerce

    Science.gov (United States)

    Wang, Xin; Sun, Jie; Li, Huihui

    2017-06-01

    As the last cake in the area of e-commerce industry, the temperature of fresh food e-commerce is always rising starting from about 2014. This paper is based on the imperfection that the existing study about fresh food e-commerce is lack of studies on storage efficiency. And we took some variables in this paper such as consumers’ satisfaction and length for preservation and storage time. On this basis we built the model of storage efficiency of fresh food e-commerce. We find that as the development of fresh food e-commerce, the fresh food e-commerce enterprise will pay more attention to the consumers’ satisfaction. They can take some effective ways like reducing the wastage of fresh food and lengthening the refreshing time of fresh food and so on.

  10. Fresh-keeping of mushroom by irradiation

    International Nuclear Information System (INIS)

    Liu Chao; Xu Hongqing; Wang Hong; Cai Jian

    2003-01-01

    The effect of 60 Co γ irradiation on the preservation of Agaricus bisporus were studied. The results showed that after irradiation the mushroom had lower rates of membrane split, opening of pilei, browning, decomposition and lose of fresh weight. The fresh keeping period of mushroom irradiated with 1.2 kGy and stored at 4 degree C was prolonged to 30 days

  11. Deriving a blood-mimicking fluid for particle image velocimetry in Sylgard-184 vascular models.

    Science.gov (United States)

    Yousif, Majid Y; Holdsworth, David W; Poepping, Tamie L

    2009-01-01

    A new blood-mimicking fluid (BMF) has been developed for particle image velocimetry (PIV), which enables flow studies in vascular models (phantoms). A major difficulty in PIV that affects measurement accuracy is the refraction and distortion of light passing through the interface between the model and the fluid, due to the difference in refractive index (n) between the two materials. The problem can be eliminated by using a fluid with a refractive index matching that of the model. Such fluids are not commonly available, especially for vascular research where the fluid should also have a viscosity similar to human blood. In this work, a blood-mimicking fluid, composed of water (47.38% by weight), glycerol (36.94% by weight) and sodium iodide salt (15.68% by weight), was developed for compatibility with our silicone (Sylgard 184; n = 1.414) phantoms. The fluid exhibits a dynamic viscosity of 4.31+/-0.03 cP which lies within the range of human blood viscosity (4.4+/-0.6 cP). Both refractive index and viscosity were attained at 22.2+/-0.2 degrees C, which is a feasible room temperature, thus eliminating the need for a temperature-control system. The fluid will be used to study hemodynamics in vascular flow models fabricated from Sylgard 184.

  12. Bundle Pricing Decisions for Fresh Products with Quality Deterioration

    OpenAIRE

    Fang, Yan; Jiang, Yiping; Han, Xingxing

    2018-01-01

    How to sell fresh products quickly to decrease the storage cost and to meet customer quality requirement is of vital importance in the food supply chain. Bundling fresh products is an efficient strategy to promote sales and reduce storage pressure of retailers. In this paper, we consider the bundle pricing decisions for homogeneous fresh products with quality deterioration. The value of fresh products with quality deterioration is approximated as an exponential function based on which custome...

  13. Imaging of Neuronal Activity in Awake Mice by Measurements of Flavoprotein Autofluorescence Corrected for Cerebral Blood Flow

    Directory of Open Access Journals (Sweden)

    Manami Takahashi

    2018-01-01

    Full Text Available Green fluorescence imaging (e.g., flavoprotein autofluorescence imaging, FAI can be used to measure neuronal activity and oxygen metabolism in living brains without expressing fluorescence proteins. It is useful for understanding the mechanism of various brain functions and their abnormalities in age-related brain diseases. However, hemoglobin in cerebral blood vessels absorbs green fluorescence, hampering accurate assessments of brain function in animal models with cerebral blood vessel dysfunctions and subsequent cerebral blood flow (CBF alterations. In the present study, we developed a new method to correct FAI signals for hemoglobin-dependent green fluorescence reductions by simultaneous measurements of green fluorescence and intrinsic optical signals. Intrinsic optical imaging enabled evaluations of light absorption and scatters by hemoglobin, which could then be applied to corrections of green fluorescence intensities. Using this method, enhanced flavoprotein autofluorescence by sensory stimuli was successfully detected in the brains of awake mice, despite increases of CBF, and hemoglobin interference. Moreover, flavoprotein autofluorescence could be properly quantified in a resting state and during sensory stimulation by a CO2 inhalation challenge, which modified vascular responses without overtly affecting neuronal activities. The flavoprotein autofluorescence signal data obtained here were in good agreement with the previous findings from a condition with drug-induced blockade of cerebral vasodilation, justifying the current assaying methodology. Application of this technology to studies on animal models of brain diseases with possible changes of CBF, including age-related neurological disorders, would provide better understanding of the mechanisms of neurovascular coupling in pathological circumstances.

  14. Improved isolation protocol for equine cord blood-derived mesenchymal stromal cells

    DEFF Research Database (Denmark)

    Koch, Thomas Gadegaard; Thomsen, Preben Dybdahl; Betts, Dean H.

    2009-01-01

      BACKGROUND AIMS: A robust methodology for the isolation of cord blood-derived multipotent mesenchymal stromal cells (CB-MSCs) from fresh umbilical cord blood has not been reported in any species. The objective of this study was to improve the isolation procedure for equine CB-MSCs. METHODS: Pre......-culture separation of red and white blood cells was done using either PrepaCyte?-EQ medium or Ficoll-Paque? PREMIUM density medium. Regular FBS and MSC-qualified FBS were compared for their ability to support the establishment of putative primary MSC colonies. RESULTS AND CONCLUSIONS: Our results indicate that Prepa...

  15. Automated red blood cells extraction from holographic images using fully convolutional neural networks

    Science.gov (United States)

    Yi, Faliu; Moon, Inkyu; Javidi, Bahram

    2017-01-01

    In this paper, we present two models for automatically extracting red blood cells (RBCs) from RBCs holographic images based on a deep learning fully convolutional neural network (FCN) algorithm. The first model, called FCN-1, only uses the FCN algorithm to carry out RBCs prediction, whereas the second model, called FCN-2, combines the FCN approach with the marker-controlled watershed transform segmentation scheme to achieve RBCs extraction. Both models achieve good segmentation accuracy. In addition, the second model has much better performance in terms of cell separation than traditional segmentation methods. In the proposed methods, the RBCs phase images are first numerically reconstructed from RBCs holograms recorded with off-axis digital holographic microscopy. Then, some RBCs phase images are manually segmented and used as training data to fine-tune the FCN. Finally, each pixel in new input RBCs phase images is predicted into either foreground or background using the trained FCN models. The RBCs prediction result from the first model is the final segmentation result, whereas the result from the second model is used as the internal markers of the marker-controlled transform algorithm for further segmentation. Experimental results show that the given schemes can automatically extract RBCs from RBCs phase images and much better RBCs separation results are obtained when the FCN technique is combined with the marker-controlled watershed segmentation algorithm. PMID:29082078

  16. Measurement of cerebral blood flow in normal subjects by phase contrast MR imaging

    International Nuclear Information System (INIS)

    Kashimada, Akio; Machida, Kikuo; Honda, Norinari; Mamiya, Toshio; Takahashi, Taku; Kamano, Tsuyoshi; Inoue, Yusuke; Osada, Hisato

    1994-01-01

    Global cerebral blood flow (CBF) was quantitatively measured with a two-dimensional phase contrast cine magnetic resonance (MR) imaging technique in 24 normal subjects (mean age, 38.6 years; range, 12-70 years). Cine transverse images of the upper cervical region (32 phases/cardiac cycle) were acquired with a 1.5 Tesla MR imaging unit. In five subjects, measurement of CBF was performed before and after intravenous administration of acetazolamide (DIAMOX, 15 mg/kg). Inter- and intra-observer variations in flow volume measurement were small (r=0.970, standard error of the estimate (SEE)=2.9 ml/min, n=8; r=0.963, SEE=4.6 ml/min, n=40, respectively). In measuring flow velocity, they were inferior to those of flow volume measurement. On a visually determined setting of region of interest (ROI), reproducibility of the measurement of flow velocity was not satisfactory in this study. Thus only the results of flow volume measurement are presented. Mean summed vertebral flow volume (171 ml/min, SD=40.6) was significantly less than mean summed internal carotid flow volume (523 ml/min, SD=111). Total blood flow volume showed a significant decline with age (r=-0.45, p<0.05). The mean proportions of carotid and vertebral flow volume to total flow volume were 75.3% and 24.7%, respectively, and showed no significant change with age. The left-to-right ratio of vertebral flow volume (1.39) was significantly higher than that of internal carotid flow volume (0.99, r=0.05). After DIAMOX i.v., the mean rate of increase in total flow volume was 157%. Mean rates of increase in carotid and vertebral flow volume were 154% and 166%, respectively, which were not significantly different. In conclusion, this method is useful for estimating carotid and vertebral flow volume. (author)

  17. 9 CFR 319.141 - Fresh pork sausage.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Fresh pork sausage. 319.141 Section... AGENCY ORGANIZATION AND TERMINOLOGY; MANDATORY MEAT AND POULTRY PRODUCTS INSPECTION AND VOLUNTARY INSPECTION AND CERTIFICATION DEFINITIONS AND STANDARDS OF IDENTITY OR COMPOSITION Sausage Generally: Fresh...

  18. Consumers' store choice behavior for fresh food

    NARCIS (Netherlands)

    Meulenberg, M.T.G.; Trijp, van J.C.M.

    1991-01-01

    Consumers' preference for fresh food stores is analyzed. In particular the choice between supermarkets and specialized shops for purchasing fresh food is analyzed. Attention is given to the factors influencing this choice. For this purpose a number of research questions with respect to store choice

  19. Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.

    Science.gov (United States)

    Romero, Cesar A; Cabral, Glauber; Knight, Robert A; Ding, Guangliang; Peterson, Edward L; Carretero, Oscar A

    2018-01-01

    Renal blood flow (RBF) provides important information regarding renal physiology and nephropathies. Arterial spin labeling-magnetic resonance imaging (ASL-MRI) is a noninvasive method of measuring blood flow without exogenous contrast media. However, low signal-to-noise ratio and respiratory motion artifacts are challenges for RBF measurements in small animals. Our objective was to evaluate the feasibility and reproducibility of RBF measurements by ASL-MRI using respiratory-gating and navigator correction methods to reduce motion artifacts. ASL-MRI images were obtained from the kidneys of Sprague-Dawley (SD) rats on a 7-Tesla Varian MRI system with a spin-echo imaging sequence. After 4 days, the study was repeated to evaluate its reproducibility. RBF was also measured in animals under unilateral nephrectomy and in renal artery stenosis (RST) to evaluate the sensitivity in high and low RBF models, respectively. RBF was also evaluated in Dahl salt-sensitive (SS) rats and spontaneous hypertensive rats (SHR). In SD rats, the cortical RBFs (cRBF) were 305 ± 59 and 271.8 ± 39 ml·min -1 ·100 g tissue -1 in the right and left kidneys, respectively. Retest analysis revealed no differences ( P = 0.2). The test-retest reliability coefficient was 92 ± 5%. The cRBFs before and after the nephrectomy were 296.8 ± 30 and 428.2 ± 45 ml·min -1 ·100 g tissue -1 ( P = 0.02), respectively. The kidneys with RST exhibited a cRBF decrease compared with sham animals (86 ± 17.6 vs. 198 ± 33.7 ml·min -1 ·100 g tissue -1 ; P < 0.01). The cRBFs in SD, Dahl-SS, and SHR rats were not different ( P = 0.35). We conclude that ASL-MRI performed with navigator correction and respiratory gating is a feasible and reliable noninvasive method for measuring RBF in rats.

  20. Blood-Based Gene Expression Signatures of Infants and Toddlers with Autism

    Science.gov (United States)

    Glatt, Stephen J.; Tsuang, Ming T.; Winn, Mary; Chandler, Sharon D.; Collins, Melanie; Lopez, Linda; Weinfeld, Melanie; Carter, Cindy; Schork, Nicholas; Pierce, Karen; Courchesne, Eric

    2012-01-01

    Objective: Autism spectrum disorders (ASDs) are highly heritable neurodevelopmental disorders that onset clinically during the first years of life. ASD risk biomarkers expressed early in life could significantly impact diagnosis and treatment, but no transcriptome-wide biomarker classifiers derived from fresh blood samples from children with…

  1. Micro-PIV (micro particle image velocimetry) visualization of red blood cells (RBCs) sucked by a female mosquito

    International Nuclear Information System (INIS)

    Kikuchi, K; Mochizuki, O

    2011-01-01

    A mosquito's pump is a highly effective system in the small suction domain. To understand a mosquito's blood suction mechanism, we analysed the characteristics of red blood cells (RBCs) in human blood during and after suction by a female mosquito. Focussing on the flow patterns of the RBCs in human blood being sucked by a mosquito, we visualized blood flow by using a micro-particle image velocimetry (μ-PIV) system, which combines an optical microscope and a PIV method. In an ex vivo experiment, a female mosquito was supplied diluted blood at the tip of the proboscis. We examined the blood flow around the tip of the proboscis and observed that RBCs were periodically sucked towards a hole around the tip. The sucked RBCs then homogeneously flowed parallel to the inner surface of the proboscis without adhering to the wall. Furthermore, using a bioelectric recording system, we directly measured electrical signals generated during suction by the pump muscles located in the mosquito's head. We found that the electrical signal power was synchronized with the acceleration of the RBCs in the sucking phase. A histological stain method was adapted for the observation of the form and internal structure of RBCs in the mosquito. Although the blood flow analysis revealed that the RBCs underwent shear stress during suction, RBCs in the mosquito's stomach maintained their original shape

  2. Inhalational anaesthesia with low fresh gas flow

    Directory of Open Access Journals (Sweden)

    Christian Hönemann

    2013-01-01

    Full Text Available During the inhalation of anaesthesia use of low fresh gas flow (0.35-1 L/min has some important advantages. There are three areas of benefit: pulmonary - anaesthesia with low fresh gas flow improves the dynamics of inhaled anaesthesia gas, increases mucociliary clearance, maintains body temperature and reduces water loss. Economic - reduction of anaesthesia gas consumption resulting in significant savings of > 75% and Ecological - reduction in nitrous oxide consumption, which is an important ozone-depleting and heat-trapping greenhouse gas that is emitted. Nevertheless, anaesthesia with high fresh gas flows of 2-6 L/min is still performed, a technique in which rebreathing is practically negligible. This special article describes the clinical use of conventional plenum vaporizers, connected to the fresh gas supply to easily perform low (1 L/min, minimal (0.5 L/min or metabolic flow anaesthesia (0.35 L/min with conventional Primus Draeger® anaesthesia machines in routine clinical practice.

  3. Information content of the space-frequency filtering of blood plasma layers laser images in the diagnosis of pathological changes

    Science.gov (United States)

    Ushenko, A. G.; Boychuk, T. M.; Mincer, O. P.; Bodnar, G. B.; Kushnerick, L. Ya.; Savich, V. O.

    2013-12-01

    The bases of method of the space-frequency of the filtering phase allocation of blood plasma pellicle are given here. The model of the optical-anisotropic properties of the albumen chain of blood plasma pellicle with regard to linear and circular double refraction of albumen and globulin crystals is proposed. Comparative researches of the effectiveness of methods of the direct polarized mapping of the azimuth images of blood plasma pcllicle layers and space-frequency polarimetry of the laser radiation transformed by divaricate and holelikc optical-anisotropic chains of blood plasma pellicles were held. On the basis of the complex statistic, correlative and fracta.1 analysis of the filtered frcquencydimensional polarizing azimuth maps of the blood plasma pellicles structure a set of criteria of the change of the double refraction of the albumen chains caused by the prostate cancer was traced and proved.

  4. Blood group typing based on recording the elastic scattering of laser radiation using the method of digital imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dolmashkin, A A; Dubrovskii, V A; Zabenkov, I V [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation)

    2012-05-31

    The possibility is demonstrated to determine the human blood group by recording the scattering of laser radiation with the help of the digital imaging method. It is experimentally shown that the action of a standing ultrasound wave leads to acceleration of the agglutination reaction of red blood cells, to formation of larger immune complexes of red blood cells, and, as a consequence, to acceleration of their sedimentation. In the absence of agglutination of red blood cells the ultrasound does not enhance the relevant processes. This difference in the results of ultrasound action on the mixture of blood and serum allows a method of blood typing to be offered. Theoretical modelling of the technique of the practical blood typing, carried out on the basis of the elastic light scattering theory, agrees well with the experimental results, which made it possible to plan further improvement of the proposed method. The studies of specific features of sedimentation of red blood cells and their immune complexes were aimed at the optimisation of the sample preparation, i.e., at the search for such experimental conditions that provide the maximal resolution of the method and the device for registering the reaction of red blood cells agglutination. The results of the study may be used in designing the instrumentation for blood group assessment in humans.

  5. Blood group typing based on recording the elastic scattering of laser radiation using the method of digital imaging

    International Nuclear Information System (INIS)

    Dolmashkin, A A; Dubrovskii, V A; Zabenkov, I V

    2012-01-01

    The possibility is demonstrated to determine the human blood group by recording the scattering of laser radiation with the help of the digital imaging method. It is experimentally shown that the action of a standing ultrasound wave leads to acceleration of the agglutination reaction of red blood cells, to formation of larger immune complexes of red blood cells, and, as a consequence, to acceleration of their sedimentation. In the absence of agglutination of red blood cells the ultrasound does not enhance the relevant processes. This difference in the results of ultrasound action on the mixture of blood and serum allows a method of blood typing to be offered. Theoretical modelling of the technique of the practical blood typing, carried out on the basis of the elastic light scattering theory, agrees well with the experimental results, which made it possible to plan further improvement of the proposed method. The studies of specific features of sedimentation of red blood cells and their immune complexes were aimed at the optimisation of the sample preparation, i.e., at the search for such experimental conditions that provide the maximal resolution of the method and the device for registering the reaction of red blood cells agglutination. The results of the study may be used in designing the instrumentation for blood group assessment in humans.

  6. Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, Chad R. R. N.; Kemp, Robert A. de, E-mail: RAdeKemp@ottawaheart.ca [Physics Department, Room 3302 Herzberg Laboratories, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6, Canada and Cardiac Imaging, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada); Klein, Ran [Department of Nuclear Medicine, Ottawa Hospital, Civic Campus, 1053 Carling Avenue, Ottawa, Ontario K1Y 4E9 (Canada); Beanlands, Rob S. [Cardiac Imaging, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario K1Y 4W7 (Canada)

    2016-04-15

    Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations

  7. Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

    International Nuclear Information System (INIS)

    Hunter, Chad R. R. N.; Kemp, Robert A. de; Klein, Ran; Beanlands, Rob S.

    2016-01-01

    Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations

  8. Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging.

    Science.gov (United States)

    Hunter, Chad R R N; Klein, Ran; Beanlands, Rob S; deKemp, Robert A

    2016-04-01

    Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET-CT misalignment. A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations also indicated that the

  9. Manufacturing and Construction of Fresh Fuel Storage Rack for a Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jinho; Lee, Sangjin; Lee, Jongmin; Ryu, Jeong-Soo [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The objective of this study is to provide the manufacturing and construction information regarding the Fresh Fuel Storage Rack (FFSR). The main function of a FFSR is to store and protect the 2 core new fuel assemblies for the operation of the research reactor. The fresh fuel assemblies are stored in a rack made of stainless steel and the storage rack is installed in the fresh fuel storage room. The fresh fuel facility provides fresh fuel assemblies with dry storage space. General design requirements of the fresh fuel storage facilities are given in the ANSI-57.3. Design, manufacturing, and construction of the fresh fuel storage rack are introduced. The analysis is performed to confirm the structural intensity of the fresh fuel storage rack under the seismic loads. The fresh fuel storage rack designed for storage of fresh fuel assemblies should be manufactured and installed with consideration of predicted number of fresh fuel assemblies, structural integrity, resistivity to corrosion and radiation, cleaning, and workability.

  10. Manufacturing and Construction of Fresh Fuel Storage Rack for a Research Reactor

    International Nuclear Information System (INIS)

    Oh, Jinho; Lee, Sangjin; Lee, Jongmin; Ryu, Jeong-Soo

    2016-01-01

    The objective of this study is to provide the manufacturing and construction information regarding the Fresh Fuel Storage Rack (FFSR). The main function of a FFSR is to store and protect the 2 core new fuel assemblies for the operation of the research reactor. The fresh fuel assemblies are stored in a rack made of stainless steel and the storage rack is installed in the fresh fuel storage room. The fresh fuel facility provides fresh fuel assemblies with dry storage space. General design requirements of the fresh fuel storage facilities are given in the ANSI-57.3. Design, manufacturing, and construction of the fresh fuel storage rack are introduced. The analysis is performed to confirm the structural intensity of the fresh fuel storage rack under the seismic loads. The fresh fuel storage rack designed for storage of fresh fuel assemblies should be manufactured and installed with consideration of predicted number of fresh fuel assemblies, structural integrity, resistivity to corrosion and radiation, cleaning, and workability

  11. The 'Fresh-Bunch' technique in FELs

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Yang, K.M.; Yu, L.H.

    1991-01-01

    The 'Fresh Bunch' technique is being proposed as a method of increasing the gain and power of FEL amplifiers in which the length of the optical radiation pulse is shorter than the length of the electron bunch. In multi-stage FEL, electron beam energy spread is increased by the FEL interaction in the early stages. In the 'Fresh Bunch' technique, the low energy spread of the electron beam is recovered by shifting the radiation pulse to an undisturbed part of the electron bunch, thus improving the gain and trapping fraction in later stages. A test case for the application of the Fresh Bunch method is demonstrated by numerical simulation. In this particular example we examine a subharmonically seeded VUV Free-Electron Laser. We begin with the generation of harmonic radiation, which takes place over one part of the electron bunch. Then the radiation is shifted by means of a strong dispersive section to a fresh part of the bunch for exponential amplification and tapered wiggler amplification. By starting over with a new ensemble of electrons, the energy spread introduced by the bunching in the fundamental is removed, leading to an increased gain. Furthermore, it is possible to use a much stronger seed in the fundamental without incurring the penalty of a large energy spread later on. We note that more than a single application of the 'Fresh Bunch' method may be done in a single FEL multiplier-amplifier. Thus x-ray wavelengths may be reached by successive multiplication in a chain of FEL amplifiers starting from a tunable seed laser. 5 refs., 2 figs., 2 tabs

  12. Magnetic particle imaging for in vivo blood flow velocity measurements in mice

    Science.gov (United States)

    Kaul, Michael G.; Salamon, Johannes; Knopp, Tobias; Ittrich, Harald; Adam, Gerhard; Weller, Horst; Jung, Caroline

    2018-03-01

    Magnetic particle imaging (MPI) is a new imaging technology. It is a potential candidate to be used for angiographic purposes, to study perfusion and cell migration. The aim of this work was to measure velocities of the flowing blood in the inferior vena cava of mice, using MPI, and to evaluate it in comparison with magnetic resonance imaging (MRI). A phantom mimicking the flow within the inferior vena cava with velocities of up to 21 cm s‑1 was used for the evaluation of the applied analysis techniques. Time–density and distance–density analyses for bolus tracking were performed to calculate flow velocities. These findings were compared with the calibrated velocities set by a flow pump, and it can be concluded that velocities of up to 21 cm s‑1 can be measured by MPI. A time–density analysis using an arrival time estimation algorithm showed the best agreement with the preset velocities. In vivo measurements were performed in healthy FVB mice (n  =  10). MRI experiments were performed using phase contrast (PC) for velocity mapping. For MPI measurements, a standardized injection of a superparamagnetic iron oxide tracer was applied. In vivo MPI data were evaluated by a time–density analysis and compared to PC MRI. A Bland–Altman analysis revealed good agreement between the in vivo velocities acquired by MRI of 4.0  ±  1.5 cm s‑1 and those measured by MPI of 4.8  ±  1.1 cm s‑1. Magnetic particle imaging is a new tool with which to measure and quantify flow velocities. It is fast, radiation-free, and produces 3D images. It therefore offers the potential for vascular imaging.

  13. Biomarker Analysis of Stored Blood Products: Emphasis on Pre-Analytical Issues

    Science.gov (United States)

    Delobel, Julien; Rubin, Olivier; Prudent, Michel; Crettaz, David; Tissot, Jean-Daniel; Lion, Niels

    2010-01-01

    Millions of blood products are transfused every year; many lives are thus directly concerned by transfusion. The three main labile blood products used in transfusion are erythrocyte concentrates, platelet concentrates and fresh frozen plasma. Each of these products has to be stored according to its particular components. However, during storage, modifications or degradation of those components may occur, and are known as storage lesions. Thus, biomarker discovery of in vivo blood aging as well as in vitro labile blood products storage lesions is of high interest for the transfusion medicine community. Pre-analytical issues are of major importance in analyzing the various blood products during storage conditions as well as according to various protocols that are currently used in blood banks for their preparations. This paper will review key elements that have to be taken into account in the context of proteomic-based biomarker discovery applied to blood banking. PMID:21151459

  14. LDH isoenzyme blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003499.htm LDH isoenzyme blood test To use the sharing features on this page, ... Names LD; LDH; Lactic (lactate) dehydrogenase isoenzymes Images Blood test References Carty RP, Pincus MR, Sarafraz-Yazdi E. ...

  15. Leucine aminopeptidase blood test

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003559.htm Leucine aminopeptidase blood test To use the sharing features on this page, ... Alternative Names Serum leucine aminopeptidase; LAP - serum Images Blood test References Chernecky CC, Berger BJ. Leucine aminopeptidase (LAP) - ...

  16. Automated high resolution full-field spatial coherence tomography for quantitative phase imaging of human red blood cells

    Science.gov (United States)

    Singla, Neeru; Dubey, Kavita; Srivastava, Vishal; Ahmad, Azeem; Mehta, D. S.

    2018-02-01

    We developed an automated high-resolution full-field spatial coherence tomography (FF-SCT) microscope for quantitative phase imaging that is based on the spatial, rather than the temporal, coherence gating. The Red and Green color laser light was used for finding the quantitative phase images of unstained human red blood cells (RBCs). This study uses morphological parameters of unstained RBCs phase images to distinguish between normal and infected cells. We recorded the single interferogram by a FF-SCT microscope for red and green color wavelength and average the two phase images to further reduced the noise artifacts. In order to characterize anemia infected from normal cells different morphological features were extracted and these features were used to train machine learning ensemble model to classify RBCs with high accuracy.

  17. [Optimization of trehalose loading in red blood cells before freeze-drying].

    Science.gov (United States)

    Zhuang, Yuan; Liu, Jing-Han; Ouyang, Xi-Lin; Chen, Lin-Feng; Che, Ji

    2007-04-01

    The key points for better protection of trehalose in freeze-drying red blood cells (RBCs) are to resolve non-osmosis of trehalose to red blood cells and to make cytoplasmic trehalose to reach effective concentration. This study was aimed to investigate the regularity of loading RBCs with trehalose, screen out optimal loading condition and evaluate the effect of trehalose on physico-chemical parameters of RBCs during the period of loading. The cytoplasmic trehalose concentration in red blood cells, free hemoglobin and ATP level were determined at different incubation temperatures (4, 22 and 37 degrees C), different trehaolse concentrations (0, 200, 400, 600, 800 and 1000 mmol/L) and different incubation times (2, 4, 6, 8 and 10 hours), the cytoplasmic trehalose, free hemoglobin (FHb), hemoglobin (Hb) and mean corpuscular volume (MCV) in fresh RBCs and RBCs stored for 72 hours at 4 degrees C were compared, when loading condition was ensured. The results showed that with increase of incubation temperature, time and extracellular trehalose concentration, the loading of trehalose in RBCs also increased. Under the optimal loading condition, cytoplasmic trehalose concentration and free hemoglobin level of fresh RBCs and RBCs stored for 72 hours at 4 degrees C were 65.505 +/- 6.314 mmol/L, 66.2 +/- 5.002 mmol/L and 6.567 +/- 2.568 g/L, 16.168 +/- 3.922 g/L respectively. It is concluded that the most optimal condition of loading trehalose is that fresh RBCs incubate in 800 mmol/L trehalose solution for 8 hours at 37 degrees C. This condition can result in a efficient cytoplasmic trehalose concentration. The study provides an important basis for long-term preservation of RBCs.

  18. A new method to study changes in microvascular blood volume in muscle and adipose tissue: Real time imaging in humans and rat

    DEFF Research Database (Denmark)

    Sjøberg, Kim Anker; Rattigan, Stephen; Hiscock, Natalie J

    2011-01-01

    We employed and evaluated a new application of contrast enhanced ultrasound for real time imaging of changes in microvascular blood volume (MVB) in tissues in females, males and rat. Continuous real time imaging was performed using contrast enhanced ultrasound to quantify infused gas filled micro...

  19. Technetium-99m-labelled red blood cell imaging in the diagnosis of hepatic haemangiomas: the role of SPECT/CT with a hybrid camera

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio; Danieli, Roberta; Manni, Carlo; Capoccetti, Francesca; Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' ' Tor Vergata' ' , Rome (Italy)

    2004-07-01

    Delayed liver single-photon emission computed tomography (SPECT) after {sup 99m}Tc red blood cell (RBC) labelling is helpful in detecting hepatic haemangiomas; however, diagnosis can be difficult when lesions are situated adjacent to structures like the inferior vena cava, the heart or hepatic vessels, where blood activity persists. The aims of this study were to evaluate the usefulness of RBC SPECT and transmission computed tomography (RBC SPECT/CT) performed simultaneously with a hybrid imaging system for correct characterisation of hepatic lesions in patients with suspected haemangioma, and to assess the additional value of fused images compared with SPECT alone. Twelve patients with 24 liver lesions were studied. The acquisitions of both anatomical (CT) and functional (SPECT) data were performed during a single session. SPECT images were first interpreted alone and then re-evaluated after adding the transmission anatomical maps. Image fusion was successful in all patients, with perfect correspondence between SPECT and CT data, allowing the precise anatomical localisation of sites of increased blood pool activity. SPECT/CT had a significant impact on results in four patients (33.3%) with four lesions defined as indeterminate on SPECT images, accurately characterising the hot spot foci located near vascular structures. In conclusion, RBC SPECT/CT imaging using this hybrid SPECT/CT system is feasible and useful in the identification or exclusion of suspected hepatic haemangiomas located near regions with high vascular activity. (orig.)

  20. High spatial resolution and high contrast visualization of brain arteries and veins. Impact of blood pool contrast agent and water-selective excitation imaging at 3T

    International Nuclear Information System (INIS)

    Spuentrup, E.; Jacobs, J.E.; Kleimann, J.F.

    2010-01-01

    Purpose: To investigate a blood pool contrast agent and water-selective excitation imaging at 3 T for high spatial and high contrast imaging of brain vessels including the veins. Methods and Results: 48 clinical patients (47 ± 18 years old) were included. Based on clinical findings, twenty-four patients received a single dose of standard extracellular Gadoterate-meglumine (Dotarem registered ) and 24 received the blood pool contrast agent Gadofosveset (Vasovist registered ). After finishing routine MR protocols, all patients were investigated with two high spatial resolution (0.15 mm 3 voxel size) gradient echo sequences in random order in the equilibrium phase (steady-state) as approved by the review board: A standard RF-spoiled gradient-echo sequence (HR-SS, TR/TE 5.1 / 2.3 msec, FA 30 ) and a fat-suppressed gradient-echo sequence with water-selective excitation (HR-FS, 1331 binominal-pulse, TR/TE 8.8 / 3.8 msec, FA 30 ). The images were subjectively assessed (image quality with vessel contrast, artifacts, depiction of lesions) by two investigators and contrast-to-noise ratios (CNR) were compared using the Student's t-test. The image quality and CNR in the HR-FS were significantly superior compared to the HR-SS for both contrast agents (p < 0.05). The CNR was also improved when using the blood pool agent but only to a minor extent while the subjective image quality was similar for both contrast agents. Conclusion: The utilized sequence with water-selective excitation improved image quality and CNR properties in high spatial resolution imaging of brain arteries and veins. The used blood pool contrast agent improved the CNR only to a minor extent over the extracellular contrast agent. (orig.)

  1. Blood Clotting and Pregnancy

    Medline Plus

    Full Text Available ... to top How are Blood Clots in Pregnant Women Treated? Typically, blood clots are treated with an ... Image Bank Advocacy Action Alerts Policy News Advocacy Leadership Institute Policy Statements Testimony & Correspondence Meetings ASH Annual ...

  2. Bio-responsive polymer hydrogels homeostatically regulate blood coagulation.

    Science.gov (United States)

    Maitz, Manfred F; Freudenberg, Uwe; Tsurkan, Mikhail V; Fischer, Marion; Beyrich, Theresa; Werner, Carsten

    2013-01-01

    Bio-responsive polymer architectures can empower medical therapies by engaging molecular feedback-response mechanisms resembling the homeostatic adaptation of living tissues to varying environmental constraints. Here we show that a blood coagulation-responsive hydrogel system can deliver heparin in amounts triggered by the environmental levels of thrombin, the key enzyme of the coagulation cascade, which--in turn--becomes inactivated due to released heparin. The bio-responsive hydrogel quantitatively quenches blood coagulation over several hours in the presence of pro-coagulant stimuli and during repeated incubation with fresh, non-anticoagulated blood. These features enable the introduced material to provide sustainable, autoregulated anticoagulation, addressing a key challenge of many medical therapies. Beyond that, the explored concept may facilitate the development of materials that allow the effective and controlled application of drugs and biomolecules.

  3. Acquired immunodeficiency syndrome associated with blood-product transfusions

    International Nuclear Information System (INIS)

    Jett, J.R.; Kuritsky, J.N.; Katzmann, J.A.; Homburger, H.A.

    1983-01-01

    A 53-year-old white man had fever, malaise, and dyspnea on exertion. His chest roentgenogram was normal, but pulmonary function tests showed impaired diffusion capacity and a gallium scan showed marked uptake in the lungs. Results of an open-lung biopsy documented Pneumocystis carinii pneumonia. Immunologic test results were consistent with the acquired immunodeficiency syndrome. The patient denied having homosexual contact or using intravenous drugs. Twenty-nine months before the diagnosis of pneumocystis pneumonia was made, the patient had had 16 transfusions of whole blood, platelets, and fresh-frozen plasma during coronary artery bypass surgery at another medical center. This patient is not a member of any currently recognized high-risk group and is believed to have contracted the acquired immunodeficiency syndrome from blood and blood-product transfusions

  4. High spatial resolution magnetic resonance imaging of experimental cerebral venous thrombosis with a blood pool contrast agent

    International Nuclear Information System (INIS)

    Spuentrup, E.; Wiethoff, A.J.; Parsons, E.C.; Spangenberg, P.; Stracke, C.P.

    2010-01-01

    Purpose: The purpose of this study was to investigate the feasibility of clot visualization in small sinus and cortical veins with contrast enhanced MRA in a cerebral venous thrombosis animal model using a blood pool contrast agent, Gadofosveset, and high spatial resolution imaging. Material and methods: For induction of cerebral venous thrombosis a recently developed combined interventional and microsurgical model was used. Cerebral sinus and cortical vein thrombosis was induced in six pigs. Two further pigs died during the procedure. Standard structural, time-of-flight- and phase contrast-angiograms were followed by fast time resolved high resolution 3D MRA (4D MRA) and subsequent high spatial resolution 3D MRA in the equilibrium phase with and without addition of parallel imaging. Visualization of the clots using the different sequences was subjectively compared and contrast-to-noise ratio (CNR) was assessed. Results: In the remaining six animals the procedure and MR-imaging protocol including administration of Gadofosveset was successfully completed. The 3D high resolution MRA in the equilibrium phase without the addition of parallel imaging was superior to all the other applied MR measurement techniques in terms of visualization of the clots. Only applying this sequence bridging vein thromboses were also seen as a small filling defect with a high CNR of >18. Conclusion: Only the non-accelerated high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset allows for high-contrast visualization of very small clots in the cerebral sinus and cortical veins. Statement clinical impact: Detection of cortical vein thrombosis is of high clinical impact. Conventional MRI sequences often fail to visualize the clot. We could demonstrate that, in contrast to conventional sequences, with high spatial resolution 3D MRA in the equilibrium in conjunction with the blood pool agent Gadofosveset very small clots in the cerebral sinus and

  5. Demonstration of the blood-ocular barrier integrity by contrast-enhanced MR imaging: A preliminary study

    International Nuclear Information System (INIS)

    Frank, J.A.; Dwyer, A.J.; Girton, M.; Sank, V.; Knop, R.H.; Gansow, O.A.; Brechbiel, M.W.; Doppman, J.L.

    1986-01-01

    In five Rhesus monkeys we assessed the potential for monitoring the blood-ocular barrier (BOB) with Gd-DTPA-enhanced MR imaging. Unilateral opening of the BOB was achieved by infusion of mannitol into the internal carotid artery. This was followed immediately by Gd-DTPA, 0.2 mmol/kg, given intravenously. T-l weighted MR images (Picken unit, 0.5 T, SE 500/40, 5-mm thickness, 15cm FOV) obtained before and within one-half hour after injection of Gd-DTPA demonstrated marked enhancement (2-to 17-fold) of the anterior and posterior chambers of the challenged eye, representing leakage of Gd-DTPA into those chambers. Animals remained free of ocular side effects

  6. Gd-EOB-DTPA-enhanced magnetic resonance images of hepatocellular carcinoma: correlation with histological grading and portal blood flow

    Energy Technology Data Exchange (ETDEWEB)

    Kogita, Sachiyo; Imai, Yasuharu; Fukuda, Kazuto; Igura, Takumi; Sawai, Yoshiyuki [Ikeda Municipal Hospital, Department of Gastroenterology, Osaka (Japan); Okada, Masahiro; Murakami, Takamichi [Kinki University, School of Medicine, Department of Radiology, Osaka (Japan); Kim, Tonsok; Onishi, Hiromitsu; Hori, Masatoshi [Osaka University, Graduate School of Medicine, Department of Radiology, Osaka (Japan); Takamura, Manabu [Ikeda Municipal Hospital, Department of Radiology, Osaka (Japan); Morimoto, Osakuni [Ikeda Municipal Hospital, Department of Surgery, Osaka (Japan); Nagano, Hiroaki [Osaka University, Graduate School of Medicine, Department of Surgery, Osaka (Japan); Wakasa, Kenichi [Osaka City University, Graduate School of Medicine, Department of Diagnostic Pathology, Osaka (Japan); Hayashi, Norio [Osaka University, Graduate School of Medicine, Department of Gastroenterology and Hepatology, Osaka (Japan)

    2010-10-15

    To retrospectively investigate enhancement patterns of hepatocellular carcinoma (HCC) and dysplastic nodule (DN) in the hepatobiliary phase of gadolinium-ethoxybenzyl-diethylenetriamine (Gd-EOB-DTPA)-enhanced MRI in relation to histological grading and portal blood flow. Sixty-nine consecutive patients with 83 histologically proven HCCs and DNs were studied. To assess Gd-EOB-DTPA uptake, we calculated the EOB enhancement ratio, which is the ratio of the relative intensity of tumorous lesion to surrounding nontumorous area on hepatobiliary phase images (post-contrast EOB ratio) to that on unenhanced images (pre-contrast EOB ratio). Portal blood flow was evaluated by CT during arterial portography. Post-contrast EOB ratios significantly decreased as the degree of differentiation declined in DNs (1.00 {+-} 0.14) and well, moderately and poorly differentiated HCCs (0.79 {+-} 0.19, 0.60 {+-} 0.27, 0.49 {+-} 0.10 respectively). Gd-EOB-DTPA uptake, assessed by EOB enhancement ratios, deceased slightly in DNs and still more in HCCs, while there was no statistical difference in the decrease between different histological grades of HCC. Reductions in portal blood flow were observed less frequently than decreases in Gd-EOB-DTPA uptake in DNs and well-differentiated HCCs. Reduced Gd-EOB-DTPA uptake might be an early event of hepatocarcinogenesis, preceding portal blood flow reduction. The hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI may help estimate histological grading, although difficulties exist in differentiating HCCs from DNs. (orig.)

  7. The effects of heated vegetable oils on blood pressure in rats

    Directory of Open Access Journals (Sweden)

    Kamsiah Jaarin

    2011-01-01

    Full Text Available OBJECTIVES: The goal of this study was to determine the possible mechanism that is involved in the blood pressureraising effect of heated vegetable oils. METHODS: Adult male Sprague-Dawley rats were divided into 11 groups; the control group was fed with rat chow, and the other groups were fed with chow that was mixed with 15% weight/weight palm or soy oils, which were either in a fresh form or heated once, twice, five, or ten times. Blood pressures were measured at the baseline and throughout the 24-week study. Plasma nitric oxide levels were assessed prior to treatment and at the end of the study. Following 24 weeks, the rats were sacrificed to investigate their vascular reactivity using the thoracic aorta. RESULTS: Palm and soy oils had no detrimental effects on blood pressure, and they significantly elevated the nitric oxide contents and reduced the contractile responses to phenylephrine. However, trials using palm and soy oils that were repeatedly heated showed an increase in blood pressure, enhanced phenylephrine-induced contractions, reduced acetylcholine- and sodium nitroprusside-induced relaxations relative to the control and rats that were fed fresh vegetable oils. CONCLUSIONS: The blood pressure-raising effect of the heated vegetable cooking oils is associated with increased vascular reactivity and a reduction in nitric oxide levels. The chronic consumption of heated vegetable oils leads to disturbances in endogenous vascular regulatory substances, such as nitric oxide. The thermal oxidation of the cooking oils promotes the generation of free radicals and may play an important contributory role in the pathogenesis of hypertension in rats.

  8. Radionuclide angiography and blood pool imaging to assess skin ulcer healing prognosis in patients with peripheral vascular disease

    International Nuclear Information System (INIS)

    Alazraki, N.; Lawrence, P.F.; Syverud, J.B.

    1984-01-01

    Several non-invasive diagnostic techniques including segmental limb blood pressures, skin fluoresence, and photo plethysmography, have been evaluated as predictors of skin ulcer healing in patients with peripheral vascular disease, but none are widely used. Using 20mCi of Tc-99m phosphate compounds, four phase bone scans were obtained, including (1) radionuclide angiogram (2) blood pool image (3) 2 hour and 4-6 hour static images and (4) 24 hour static delayed images. The first two phases were used to assess vacularity to the region of distal extremity ulceration; the last two phases evaluated presence or absence of osteomyelitis. Studies were performed in 30 patients with non-healing ulcers of the lower extremities. Perfusion to the regions of ulceration on images was graded as normal, increased, or reduced with respect to the opposite (presumed normal) limb or some other normal reference area. Hypervascular response was interpreted as good prognosis for healing unless osteomyelitis was present. Clinicians followed patients for 14 days to assess limb healing with optimum care. If there was no improvement, angiography and/or surgery (reconstructive surgery, sympathectomy, or amputation) was done. Results showed: sensitivity for predicting ulcer healing was 94%, specificity 89%. Patients who failed to heal their ulcers showed reduced perfusion, no hypervascular response, or osteomyelitis. Microcirculatory adequacy for ulcer healing appear predictable by this technique

  9. Ground Zero/Fresh Kills: Cataloguing Ruins, Garbage, and Memory

    Directory of Open Access Journals (Sweden)

    Cinzia Scarpino

    2011-09-01

    Full Text Available The aim of this paper is to show how the rise and fall of the Twin Towers can be read in relation to the rise and fall of the Staten Island Fresh Kills landfill, how their destinies were entwined from the start, and how the immediate cultural response to the collapse of the former and the closing of the latter recurred to the form of catalogues of objects, words, and images. From this angle it will be possible to posit the events within a larger, if somewhat unusual, cultural frame encompassing the history of two different yet complementary symbols of New York up to 2001 (the WTC and Fresh Kills. From Don DeLillo’s Underworld (1997 and Falling Man (2007 through Holman, Steve Zeitlin e Joe Dobkin’s Crisis (2001-2002; from Art Spiegelman’s In the Shadows of No Tower (2004 to Artists Respond’s 9-11 (2002; from the New York Times to Bearing Witness to History, the 2003-2006 retrospective of the Smithsonian Museum, relevant collective or individual responses to the 2001 attacks took the form of a catalogue, a list, a vertical or horizontal juxtaposition of data, objects, and memories, evoking a suggestive parallel to the organizing principle of past relics collected in museums and garbage stratified in sanitary landfills.

  10. Effect of Blood Contamination on Marginal Adaptation and Surface Microstructure of Mineral Trioxide Aggregate: A SEM Study.

    Science.gov (United States)

    Salem Milani, Amin; Rahimi, Saeed; Froughreyhani, Mohammad; Vahid Pakdel, Mahdi

    2013-01-01

    In various clinical situations, mineral trioxide aggregate (MTA) may come into direct contact or even be mixed with blood. The aim of the present study was to evaluate the effect of exposure to blood on marginal adaptation and surface microstructure of MTA. Thirty extracted human single-rooted teeth were used. Standard root canal treatment was carried out. Root-ends were resected, and retrocavities were prepared. The teeth were randomly divided into two groups (n = 15): in group 1, the internal surface of the cavities was coated with fresh blood. Then, the cavities were filled with MTA. The roots were immersed in molds containing fresh blood. In group 2, the aforementioned procedures were performed except that synthetic tissue fluid (STF) was used instead of blood. To assess the marginal adaptation, "gap perimeter" and "maximum gap width" were measured under scanning electron microscope. The surface microstructure was also examined. Independent samples t-test and Mann-Whitney U test were used to analyze the data. Maximum gap width and gap perimeter in the blood-exposed group were significantly larger than those in the STF-exposed group (p < 0.01). In the blood-exposed group, the crystals tended to be more rounded and less angular compared with the STF-exposed group, and there was a general lack of needle-like crystals. Exposure to blood during setting has a negative effect on marginal adaptation of MTA, and blood-exposed MTA has a different surface microstructure compared to STF-exposed MTA.

  11. Segmentation, Reconstruction, and Analysis of Blood Thrombus Formation in 3D 2-Photon Microscopy Images

    Directory of Open Access Journals (Sweden)

    Xu Zhiliang

    2010-01-01

    Full Text Available We study the problem of segmenting, reconstructing, and analyzing the structure growth of thrombi (clots in blood vessels in vivo based on 2-photon microscopic image data. First, we develop an algorithm for segmenting clots in 3D microscopic images based on density-based clustering and methods for dealing with imaging artifacts. Next, we apply the union-of-balls (or alpha-shape algorithm to reconstruct the boundary of clots in 3D. Finally, we perform experimental studies and analysis on the reconstructed clots and obtain quantitative data of thrombus growth and structures. We conduct experiments on laser-induced injuries in vessels of two types of mice (the wild type and the type with low levels of coagulation factor VII and analyze and compare the developing clot structures based on their reconstructed clots from image data. The results we obtain are of biomedical significance. Our quantitative analysis of the clot composition leads to better understanding of the thrombus development, and is valuable to the modeling and verification of computational simulation of thrombogenesis.

  12. Coagulation parameters as a guide for fresh frozen plasma transfusion practice: A tertiary hospital experience

    Directory of Open Access Journals (Sweden)

    Wan Haslindawani W

    2010-01-01

    Full Text Available Introduction: The appropriate use of blood and blood products means the transfusion of safe blood products only to treat a condition leading to significant morbidity or mortality, which cannot be prevented or managed effectively by other means. The safety and effectiveness of transfusion depend on the appropriate clinical use of blood and blood products. This study was conducted to review the practice of fresh frozen plasma usage (FFP for transfusion, based on the coagulation profile, requested by various departments in the Hospital Universiti Sains Malaysia (HUSM. Methodology: A retrospective review of blood bank records and coagulation profile results of the patients given FFP from October to December 2006, in Hospital USM was undertaken. The criteria set by the College of American Pathologists in 1994, were used as the guidelines. Results: One thousand six hundred and ninety-eight units of FFP were used during this study period. Only 806 (47.47% FFP units were deemed appropriate. 20.38% were based on studies without any coagulation tests prior to transfusion and 21.13% were transfused for mild prolongation of coagulation test results. About 6.41% requested FFP in the setting of normal coagulation results. Conclusion: Our results showed that a significant proportion of the FFP transfusion was not guided by the coagulation profile. We recommend that a continuous education on FFP transfusion may help to guide the appropriate request for FFP.

  13. Effects of Eating Fresh Lean Pork on Cardiometabolic Health Parameters

    Directory of Open Access Journals (Sweden)

    Peter R. C. Howe

    2012-07-01

    Full Text Available High protein meat-based diets are commonly promoted for weight loss, supposedly by increasing satiety and energy expenditure. Pork is a good source of protein however little information on the metabolic effects of pork consumption exists. This pilot study aimed to examine whether regular consumption of fresh lean pork could improve body composition and cardiovascular risk factors in a 6 month parallel intervention trial. 164 overweight adults (mean BMI 32 were randomly assigned to incorporate up to 1 kg pork/week by substituting for other foods or maintain their habitual diet (control. Plasma levels of lipids, glucose and insulin, BMI, waist/hip circumference, blood pressure, heart rate and arterial compliance were measured at baseline and 3 and 6 months. Body composition was determined using dual energy X-ray absorptiometry. A total of 144 volunteers completed and volunteers in the pork group increased their intake 10 fold by substituting pork for mainly beef and chicken. After 3 months, there were significant (p ≤ 0.01 reductions in weight, BMI, waist circumference, % body fat, fat mass and abdominal fat in the pork group relative to controls, which persisted for 6 months. There was no change in lean mass, indicating that the reduction in weight was due to loss of fat mass. There were no significant effects on other metabolic parameters. Regular consumption of lean fresh pork may improve body composition.

  14. Shallow and deep fresh impact craters in Hesperia Planum, Mars

    Science.gov (United States)

    Mouginis-Mark, Peter J.; Hayashi, Joan N.

    1993-01-01

    The depths of 109 impact craters about 2-16 km in diameter, located on the ridged plains materials of Hesperia Planum, Mars, have been measured from their shadow lengths using digital Viking Orbiter images (orbit numbers 417S-419S) and the PICS computer software. On the basis of their pristine morphology (very fresh lobate ejecta blankets, well preserved rim crests, and lack of superposed impact craters), 57 of these craters have been selected for detailed analysis of their spatial distribution and geometry. We find that south of 30 deg S, craters less than 6.0 km in diameter are markedly shallower than similar-sized craters equatorward of this latitude. No comparable relationship is observed for morphologically fresh craters greater than 6.0 km diameter. We also find that two populations exist for older craters less than 6.0 km diameter. When craters that lack ejecta blankets are grouped on the basis of depth/diameter ratio, the deeper craters also typically lie equatorward of 30 S. We interpret the spatial variation in crater depth/diameter ratios as most likely due to a poleward increase in volatiles within the top 400 m of the surface at the times these craters were formed.

  15. Accurate costs of blood transfusion: a microcosting of administering blood products in the United Kingdom National Health Service.

    Science.gov (United States)

    Stokes, Elizabeth A; Wordsworth, Sarah; Staves, Julie; Mundy, Nicola; Skelly, Jane; Radford, Kelly; Stanworth, Simon J

    2018-04-01

    In an environment of limited health care resources, it is crucial for health care systems which provide blood transfusion to have accurate and comprehensive information on the costs of transfusion, incorporating not only the costs of blood products, but also their administration. Unfortunately, in many countries accurate costs for administering blood are not available. Our study aimed to generate comprehensive estimates of the costs of administering transfusions for the UK National Health Service. A detailed microcosting study was used to cost two key inputs into transfusion: transfusion laboratory and nursing inputs. For each input, data collection forms were developed to capture staff time, equipment, and consumables associated with each step in the transfusion process. Costing results were combined with costs of blood product wastage to calculate the cost per unit transfused, separately for different blood products. Data were collected in 2014/15 British pounds and converted to US dollars. A total of 438 data collection forms were completed by 74 staff. The cost of administering blood was $71 (£49) per unit for red blood cells, $84 (£58) for platelets, $55 (£38) for fresh-frozen plasma, and $72 (£49) for cryoprecipitate. Blood administration costs add substantially to the costs of the blood products themselves. These are frequently incurred costs; applying estimates to the blood components supplied to UK hospitals in 2015, the annual cost of blood administration, excluding blood products, exceeds $175 (£120) million. These results provide more accurate estimates of the total costs of transfusion than those previously available. © 2018 AABB.

  16. Creating Sustainable Fresh Food Supply Chains through Waste Reduction

    DEFF Research Database (Denmark)

    Kaipia, Riikka; Dukovska-Popovska, Iskra; Loikkanen, Lauri

    2013-01-01

    . Design/methodology/approach – This work has been designed as an exploratory case study in three fresh food supply chains, milk, fresh fish, and fresh poultry, in the Nordic countries. The cases are based on interviews and data from the databases of the companies involved. Each case focuses on analyzing...... uses of shared information to create a sustainable fresh food supply chain. Findings –The performance of the perishable food chain can be improved by more efficient information sharing. The key to improved operations is how and for which purposes the shared data should be used. In addition, changes......Purpose – The aim of this empirical paper is to study information sharing in fresh food supply chains, with a specific goal of reducing waste and facilitating sustainable performance. The study focuses on material and information flow issues, specifically on sharing demand and shelf-life data...

  17. Immediate renal imaging and renography with /sup 99m/Tc methylene diphosphonate to assess renal blood flow, excretory function, and anatomy

    International Nuclear Information System (INIS)

    Glass, E.C.; DeNardo, G.L.; Hines, H.H.

    1980-01-01

    /sup 99m/Tc methylene diphosphonate (/sup 99m/Tc MDP) was evaluated as a clinical renal imaging agent in 20 patients referred for bone scintigraphy. Sequential scintigraphy, which was started immediately after injection, yielded blood flow studies of high quality, and subsequent images accurately delineated renal anatomy and excretion in nonazotemic patients. In comparison with delayed images, early images were vastly superior in quality and demonstrated improved target-to-nontarget activity ratios (p < 0.001) and improved lesion detectability (p < 0.01). Renal imaging performed incidental to bone scintigraphy with MDP can be greatly enhanced by initiating sequential scintigraphy immediately after injection

  18. [Whole-blood transfusion for hemorrhagic shock resuscitation: two cases in Djibouti].

    Science.gov (United States)

    Cordier, P Y; Eve, O; Dehan, C; Topin, F; Menguy, P; Bertani, A; Massoure, P L; Kaiser, E

    2012-01-01

    Hemorrhagic shock requires early aggressive treatment, including transfusion of packed red blood cells and hemostatic resuscitation. In austere environments, when component therapy is not available, warm fresh whole-blood transfusion is a convenient treatment. It provides red blood cells, clotting factors, and functional platelets. Therefore it is commonly used in military practice to treat hemorrhagic shock in combat casualties. At Bouffard Hospital Center in Djibouti, the supply of packed red blood cells is limited, and apheresis platelets are unavailable. We used whole blood transfusion in two civilian patients with life-threatening non-traumatic hemorrhages. One had massive bleeding caused by disseminated intravascular coagulation due to septic shock; the second was a 39 year-old pregnant woman with uterine rupture. In both cases, whole blood transfusion (twelve and ten 500 mL bags respectively), combined with etiological treatment, enabled coagulopathy correction, hemorrhage control, and satisfactory recovery.

  19. Cerebral misery perfusion diagnosed using hypercapnic blood-oxygenation-level-dependent contrast functional magnetic resonance imaging: a case report

    Directory of Open Access Journals (Sweden)

    D'Souza Olympio

    2010-02-01

    Full Text Available Abstract Introduction Cerebral misery perfusion represents a failure of cerebral autoregulation. It is an important differential diagnosis in post-stroke patients presenting with collapses in the presence of haemodynamically significant cerebrovascular stenosis. This is particularly the case when cortical or internal watershed infarcts are present. When this condition occurs, further investigation should be done immediately. Case presentation A 50-year-old Caucasian man presented with a stroke secondary to complete occlusion of his left internal carotid artery. He went on to suffer recurrent seizures. Neuroimaging demonstrated numerous new watershed-territory cerebral infarcts. No source of arterial thromboembolism was demonstrable. Hypercapnic blood-oxygenation-level-dependent-contrast functional magnetic resonance imaging was used to measure his cerebrovascular reserve capacity. The findings were suggestive of cerebral misery perfusion. Conclusions Blood-oxygenation-level-dependent-contrast functional magnetic resonance imaging allows the inference of cerebral misery perfusion. This procedure is cheaper and more readily available than positron emission tomography imaging, which is the current gold standard diagnostic test. The most evaluated treatment for cerebral misery perfusion is extracranial-intracranial bypass. Although previous trials of this have been unfavourable, the results of new studies involving extracranial-intracranial bypass in high-risk patients identified during cerebral perfusion imaging are awaited. Cerebral misery perfusion is an important and under-recognized condition in which emerging imaging and treatment modalities present the possibility of practical and evidence-based management in the near future. Physicians should thus be aware of this disorder and of recent developments in diagnostic tests that allow its detection.

  20. Pork loin quality is not indicative of fresh belly or fresh and cured ham quality.

    Science.gov (United States)

    Arkfeld, E K; Wilson, K B; Overholt, M F; Harsh, B N; Lowell, J E; Hogan, E K; Klehm, B J; Bohrer, B M; Mohrhauser, D A; King, D A; Wheeler, T L; Dilger, A C; Shackelford, S D; Boler, D D

    2016-12-01

    The objective was to characterize the relationship between fresh loin quality with fresh belly or fresh and cured ham quality. Pigs raised in 8 barns representing 2 seasons [cold ( = 4,290) and hot ( = 3,394)] and 2 production focuses [lean ( = 3,627) and quality ( = 4,057)] were used. Carcass characteristics and other meat quality data were collected on 7,684 carcasses. All of the carcasses were evaluated for HCW, LM depth, tenth rib fat depth, leg (ham primal) weight, instrumental color on the gluteus medius and gluteus profundus of the ham face, and subjective loin quality. Instrumental loin color and ultimate pH (≥ 22 h postmortem) were collected on the ventral side of loins along with dimensions and firmness scores of fresh bellies from 50% of the carcasses. Ten percent of the boneless loins and fresh hams were evaluated for slice shear force (SSF) or cured ham characteristics. Correlation coefficients between traits were computed using the CORR procedure of SAS and considered significantly different from 0 at ≤ 0.05. Temperature decline, beginning at 31 min postmortem and concluding at 22 h postmortem, for the longissimus dorsi and semimembranosus muscles were evaluated on 10% of the carcasses. Ultimate loin pH was correlated with dimensional belly characteristics ( ≥ |0.07|; ham instrumental color ( ≥ |0.03|; ≤ 0.05), and semimembranosus ultimate pH ( = 0.33; hams. Instrumental L*on the ventral surface of the loin was related to L* on both muscles of the ham face ( ≤ 0.0001). Even though significant relationships between the loin, belly, and ham were detected, the variability in belly and ham quality explained by variability in loin quality was poor (≤ 22.09%). Compositional differences between the loin and belly may have contributed to those poor relationships. Additionally, differences in temperature declines during chilling between the loin and ham likely contributed to the weak nature of relationships. Equilibration of longissimus dorsi

  1. Multi spectral imaging analysis for meat spoilage discrimination

    DEFF Research Database (Denmark)

    Christiansen, Asger Nyman; Carstensen, Jens Michael; Papadopoulou, Olga

    classification methods: Naive Bayes Classifier as a reference model, Canonical Discriminant Analysis (CDA) and Support Vector Classification (SVC). As the final step, generalization of the models was performed using k-fold validation (k=10). Results showed that image analysis provided good discrimination of meat......In the present study, fresh beef fillets were purchased from a local butcher shop and stored aerobically and in modified atmosphere packaging (MAP, CO2 40%/O2 30%/N2 30%) at six different temperatures (0, 4, 8, 12, 16 and 20°C). Microbiological analysis in terms of total viable counts (TVC......) was performed in parallel with videometer image snapshots and sensory analysis. Odour and colour characteristics of meat were determined by a test panel and attributed into three pre-characterized quality classes, namely Fresh; Semi Fresh and Spoiled during the days of its shelf life. So far, different...

  2. 78 FR 32184 - Importation of Fresh Apricots From Continental Spain

    Science.gov (United States)

    2013-05-29

    .... APHIS-2011-0132] RIN 0579-AD62 Importation of Fresh Apricots From Continental Spain AGENCY: Animal and... United States of fresh apricots from continental Spain. This action will allow interested persons... importation of fruits and vegetables to allow the importation of fresh apricots from continental Spain into...

  3. Microbiological Quality of Fresh Nopal Juice.

    Science.gov (United States)

    Hernández-Anguiano, Ana María; Landa-Salgado, Patricia; Eslava-Campos, Carlos Alberto; Vargas-Hernández, Mateo; Patel, Jitendra

    2016-12-10

    The consumption of fresh nopal cactus juice is widely popular among health-conscious consumers in Mexico. The juice is prepared from fresh cladodes that have only been rinsed with tap water and are not subjected to a pasteurization or terminal bacterial reduction process. The aim of this study was to evaluate the microbial quality of commercially available fresh juices ( n = 162) made with nopal in Texcoco, State of Mexico, during the summer and spring season. Standard microbiological methods, the PCR technique and the serological method were used for isolation and identification of bacteria. All samples contained total coliforms and 91% were positive for Escherichia coli . Although total coliforms and E. coli were detected throughout the study, their populations were significantly lower ( p nopal juices is unacceptable due to its health significance. The information generated in this study is relevant for human health risk assessment associated with the consumption of unpasteurized nopal juices and potential interventions to minimize pathogen contamination.

  4. Fresh water generators onboard a floating platform

    International Nuclear Information System (INIS)

    Tewari, P.K.; Verma, R.K.; Misra, B.M.; Sadhulkan, H.K.

    1997-01-01

    A dependable supply of fresh water is essential for any ocean going vessel. The operating and maintenance personnel on offshore platforms and marine structures also require a constant and regular supply of fresh water to meet their essential daily needs. A seawater thermal desalination unit onboard delivers good quality fresh water from seawater. The desalination units developed by Bhabha Atomic Research Centre (BARC) suitable for ocean going vessels and offshore platforms have been discussed. Design considerations of such units with reference to floating platforms and corrosive environments have been presented. The feasibility of coupling a low temperature vacuum evaporation (LTVE) desalination plant suitable for an onboard floating platform to a PHWR nuclear power plant has also been discussed. (author). 1 ref., 3 figs, 2 tabs

  5. Promoting seafood consumption: An evaluation of the Danish campaign for fresh fish

    DEFF Research Database (Denmark)

    Scholderer, Joachim; Grunert, Klaus G.

    2003-01-01

    was that preparing a tasty meal from fresh fish was actually not difficult. In supplementary materials consumers were provided with recipes for fresh fish. At the same time, major retail chains made MAP-packaged fresh fish filets available in Danish supermarkets. The influence of family expectations was harnessed......Before and after the 3-year generic advertising campaign for fresh fish in Denmark, representative consumer samples were surveyed with regard to their attitudes towards fresh fish, perceived family norms, availability of fresh fish in shops, meal preparation skills, intentions to buy fresh fish......, and actual consumption frequencies. In the pre-campaign survey (effective N = 641), significant determinants of consumption were availability in shops, meal preparation skills, and intentions to buy fresh fish. The campaign was especially designed to conquer these barriers. The key proposition...

  6. Microbial and preservative safety of fresh and processed fruit salads ...

    African Journals Online (AJOL)

    The producers and traders of fresh fruit and the processers should implement quality management practices and safety standards in farming, fresh fruit, processing and storage. This is to ensure safety, enhance consumption of fruits and fruit products for health of consumers and eliminate wastage. Key words: Fresh fruit, ...

  7. 7 CFR 457.148 - Fresh market pepper crop insurance provisions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Fresh market pepper crop insurance provisions. 457.148... pepper crop insurance provisions. The fresh market pepper crop insurance provisions for the 1999 and... Fresh Market Pepper Crop Provisions If a conflict exists among the policy provisions, the order of...

  8. Allelopathic effect of aqueous extract of fresh leaf castor beans ...

    African Journals Online (AJOL)

    Rukevwe S. Abraka

    2016-12-07

    Dec 7, 2016 ... In this study, the allelopathic effect of aqueous extract from fresh leaves of castor .... triturated with electric blender and sieved for the extract preparation. .... (A), Leaf fresh mass; (B), root fresh mass; (C), stem diameter; (D), aerial part length. .... Naphthoquinones as allelochemical triggers of programmed cell.

  9. Bioactive substance accumulation and septic complications in a burn trauma patient: effect of perioperative blood transfusion?

    DEFF Research Database (Denmark)

    Nielsen, H J; Reimert, C M; Dybkjaer, E

    1997-01-01

    cationic protein (ECP), eosinophil protein X (EPX), neutrophil myeloperoxidase (MPO) and interleukin 6 (IL-6) were drawn frequently from the patient before, during and after the operations, and from all transfused red cell, platelet and fresh frozen plasma units. Urine was sampled every hour during......Evidence has emerged that suggests adverse effects to perioperative homologous blood transfusion are related to the age of the blood products. Recently, time-dependent accumulation of bioactive substances in red cell suspensions, standard platelet concentrates and fresh frozen plasma during storage...... have been shown. The potential adverse effects of these bioactive substances were analysed in a burn trauma patient. A patient with 40 per cent second and third degree burn trauma without other injuries underwent a two-step transplantation operation. Samples for analyses of histamine, eosinophil...

  10. Radionuclide method for blood volume determination in kidneys

    International Nuclear Information System (INIS)

    Trindev, P.; Nikolov, D.; Shejretova, E.; Garcheva-Tsacheva, M.

    1989-01-01

    The method is applied in nephrology for diagnosing changes in blood circulation of the kidneys. The blood volume of each kidney is determined separately by perfusion angioscintigraphy (PAS) with improved accuracy. The method consists in intravenous injection of 300-450 MBq 99m Tc for in-vivo labelling of the erythrocytes. About 30 images are registered every 2 sec, and through zones of interest perfusion histograms of kidneys are derived. Ten minutes later kidneys images (one full-face and two profiles) are registered. Correction coefficients for kidneys depth are derived and the activities registered according to full-face images and amplitudes of perfusion histograms are corrected. The activity of 1 ml blood is determined from blood sample of the patient. The blood volume of each kidney is expressed as a ratio of the activity corrected for background and depth and the activity of 1 ml blood of the sample. 1 claim

  11. Ionising energy treatment of fresh fruit

    International Nuclear Information System (INIS)

    Rigney, C.J.

    1985-01-01

    The main purposes of the ionising energy treatment of fresh fruit are: the extension of shelf life of the commodity due to a direct physiological effect on the particular product; the extension of shelf life of the commodity due to a reduction in the development of moulds and rots which would normally render the product worthless; and the killing of insect pests of quarantine significance, to allow for normal marketing of fresh fruit without the risk of introducing insect pests to previously pest-free areas

  12. Identifying risk event in Indonesian fresh meat supply chain

    Science.gov (United States)

    Wahyuni, H. C.; Vanany, I.; Ciptomulyono, U.

    2018-04-01

    The aim of this paper is to identify risk issues in Indonesian fresh meat supply chain from the farm until to the “plate”. The critical points for food safety in physical fresh meat product flow are also identified. The paper employed one case study in the Indonesian fresh meat company by conducting observations and in-depth three stages of interviews. At the first interview, the players, process, and activities in the fresh meat industry were identified. In the second interview, critical points for food safety were recognized. The risk events in each player and process were identified in the last interview. The research will be conducted in three stages, but this article focuses on risk identification process (first stage) only. The second stage is measuring risk and the third stage focuses on determining the value of risk priority. The results showed that there were four players in the fresh meat supply chain: livestock (source), slaughter (make), distributor and retail (deliver). Each player has different activities and identified 16 risk events in the fresh meat supply chain. Some of the strategies that can be used to reduce the occurrence of such risks include improving the ability of laborers on food safety systems, improving cutting equipment and distribution processes

  13. Fresh Water Technology

    International Nuclear Information System (INIS)

    Ko, Yang Mun; Kim, O Sik; Kim, Jin Nam; Kim, Cheol Su

    1985-02-01

    This book tells US summary of fresh water with evaporation system like basic principle and outline, multistage flash evaporation, multiple-effect evaporation, other evaporation, evaporation plant by development merger, design of evaporation plant, reverse osmosis on summary, type and production of membrane, reverse osmosis device, reverse osmosis process, electrodialysis with outline of electrodialysis and polarization and energy, freezing preservation and corrosion and scale.

  14. Evaluation of Fresh Food Internet Shopping in Korean Beef

    OpenAIRE

    金, 鍾和; 森高, 正博; 福田, 晋; Kim, Jong-hwa; Moritaka, Masahiro; Fukuda, Susumu

    2013-01-01

    This paper focuses on consumer reactions to the fresh food internet shopping on Korea beef. In the paper, we have analyzed an effective relation in consumer's perceived qualities, the evaluation of commodities and the evaluation of fresh food internet shopping. As a result, two effective relations were found. Firstly, consumer's perceived qualities affect the evaluation of commodities. Secondly, the evaluation of commodities affects t-he evaluation of fresh food internet shopping. This result...

  15. Implementation of a comprehensive blood conservation program can reduce blood use in a community cardiac surgery program.

    Science.gov (United States)

    Xydas, Steve; Magovern, Christopher J; Slater, James P; Brown, John M; Bustami, Rami; Parr, Grant V; Thurer, Robert L

    2012-04-01

    The study objective was to determine the effects of implementing a blood conservation algorithm on blood product use and outcomes in a community cardiac surgery program. A blood management strategy including lower hemoglobin transfusion threshold and algorithm-driven decisions was adopted. Intraoperatively, point-of-care testing was used to avoid inappropriate component transfusion. A low prime perfusion circuit was adopted. Blood was withdrawn from patients before initiating bypass when possible. Patients undergoing coronary and valve procedures were included. Outlier patients receiving more than 10 units packed red blood cells were excluded. Data were collected for 6 months as a baseline group (group I). A 3-month period of program implementation was allotted. Data were subsequently collected for 6 months and comprised the study patients (group II). Prospective data were collected on demographics, blood use, and outcomes. Group I comprised 481 patients, and group II comprised 551 patients. Group II received fewer units of packed red blood cells, fresh-frozen plasma, and cryoprecipitate than group I. There was no difference in platelets transfused. Total blood product use was reduced by 40% in group II (P conservation algorithm can be rapidly introduced, leading to reductions in blood and component use with no detrimental effect on early outcomes. Point-of-care testing can direct component transfusion in coagulopathic cases, with most coagulopathic patients requiring platelets. Further research will determine the effects of reduced transfusions on long-term outcomes. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  16. Platelets in blood stored in untreated and siliconed glass bottles and plastic bags

    Science.gov (United States)

    Kissmeyer-Nielsen, F.; Madsen, C. B.; Nedergaard, Jytte

    1961-01-01

    Platelet survival was determined using untreated and siliconed glass bottles and plastic bags (Fenwal) for collecting and storing blood. The platelets were tagged in vivo with P32 in six polycythaemic patients undergoing treatment with P32. The results showed that fresh ACD blood collected in untreated glass, siliconed glass, and plastic gave the same recovery of platelets in the recipients. The use of EDTA (Fenwal formula) as anticoagulant gave results inferior to those obtained with blood using ACD as anticoagulant. Even after storage up to 24 hours in untreated glass bottles (ordinary bank blood) a satisfactory recovery of platelets was observed. After storage for 72 hours the recovery was less but not negligible. PMID:14456481

  17. Determining tumor blood flow parameters from dynamic image measurements

    Science.gov (United States)

    Libertini, Jessica M.

    2008-11-01

    Many recent cancer treatments focus on preventing angiogenesis, the process by which a tumor promotes the growth of large and efficient capillary beds for the increased nourishment required to support the tumor's rapid growth[l]. To measure the efficacy of these treatments in a timely fashion, there is an interest in using data from dynamic sequences of contrast-enhanced medical imaging, such as MRI and CT, to measure blood flow parameters such as perfusion, permeability-surface-area product, and the relative volumes of the plasma and extracellular-extravascular space. Starting with a two compartment model presented by the radiology community[2], this work challenges the application of a simplification to this problem, which was originally developed to model capillary reuptake[3]. While the primary result of this work is the demonstration of the inaccuracy of this simplification, the remainder of the paper is dedicated to presenting alternative methods for calculating the perfusion and plasma volume coefficients. These methods are applied to model data sets based on real patient data, and preliminary results are presented.

  18. Cultivation, isolation and characterization of bacteriocin from fresh ...

    African Journals Online (AJOL)

    This study focus on cultivation, isolation and characterization of Bacteriocin from fresh cow milk (FCM) and fresh cow meat (FMS) samples obtained from Lapai Market in Niger State, Nigeria. Potential bacteriocinogenic bacteria were screened with agar diffusion method on culture plates seeded with Staphylococcus and ...

  19. Remote non-invasive stereoscopic imaging of blood vessels: first in-vivo results of a new multispectral contrast enhancement technology

    NARCIS (Netherlands)

    Wieringa, F.P.; Mastik, F.; Cate, F.J. ten; Neumann, H.A.M.; Steen, A.F.W. van der

    2006-01-01

    We describe a contactless optical technique selectively enhancing superficial blood vessels below variously pigmented intact human skin by combining images in different spectral bands. Two CMOS-cameras, with apochromatic lenses and dual-band LED-arrays, simultaneously streamed Left (L) and Right (R)

  20. Online hyperspectral imaging system for evaluating quality of agricultural products

    Science.gov (United States)

    Mo, Changyeun; Kim, Giyoung; Lim, Jongguk

    2017-06-01

    The consumption of fresh-cut agricultural produce in Korea has been growing. The browning of fresh-cut vegetables that occurs during storage and foreign substances such as worms and slugs are some of the main causes of consumers' concerns with respect to safety and hygiene. The purpose of this study is to develop an on-line system for evaluating quality of agricultural products using hyperspectral imaging technology. The online evaluation system with single visible-near infrared hyperspectral camera in the range of 400 nm to 1000 nm that can assess quality of both surfaces of agricultural products such as fresh-cut lettuce was designed. Algorithms to detect browning surface were developed for this system. The optimal wavebands for discriminating between browning and sound lettuce as well as between browning lettuce and the conveyor belt were investigated using the correlation analysis and the one-way analysis of variance method. The imaging algorithms to discriminate the browning lettuces were developed using the optimal wavebands. The ratio image (RI) algorithm of the 533 nm and 697 nm images (RI533/697) for abaxial surface lettuce and the ratio image algorithm (RI533/697) and subtraction image (SI) algorithm (SI538-697) for adaxial surface lettuce had the highest classification accuracies. The classification accuracy of browning and sound lettuce was 100.0% and above 96.0%, respectively, for the both surfaces. The overall results show that the online hyperspectral imaging system could potentially be used to assess quality of agricultural products.

  1. Thermographic venous blood flow characterization with external cooling stimulation

    Science.gov (United States)

    Saxena, Ashish; Ng, E. Y. K.; Raman, Vignesh

    2018-05-01

    Experimental characterization of blood flow in a human forearm is done with the application of continuous external cooling based active thermography method. Qualitative and quantitative detection of the blood vessel in a thermal image is done, along with the evaluation of blood vessel diameter, blood flow direction, and velocity in the target blood vessel. Subtraction based image manipulation is performed to enhance the feature contrast of the thermal image acquired after the removal of external cooling. To demonstrate the effect of occlusion diseases (obstruction), an external cuff based occlusion is applied after the removal of cooling and its effect on the skin rewarming is studied. Using external cooling, a transit time method based blood flow velocity estimation is done. From the results obtained, it is evident that an external cooling based active thermography method can be used to develop a diagnosis tool for superficial blood vessel diseases.

  2. Effect of Blood Contamination on Marginal Adaptation and Surface Microstructure of Mineral Trioxide Aggregate: A SEM Study

    Directory of Open Access Journals (Sweden)

    Amin Salem Milani

    2013-08-01

    Full Text Available Background and aims. In various clinical situations, mineral trioxide aggregate (MTA may come into direct contact or even be mixed with blood. The aim of the present study was to evaluate the effect of exposure to blood on marginal adaptation and surface microstructure of MTA. Materials and methods. Thirty extracted human single-rooted teeth were used. Standard root canal treatment was carried out. Root-ends were resected, and retrocavities were prepared. The teeth were randomly divided into two groups (n = 15: in group 1, the internal surface of the cavities was coated with fresh blood. Then, the cavities were filled with MTA. The roots were immersed in molds containing fresh blood. In group 2, the aforementioned procedures were performed except that synthetic tissue fluid (STF was used instead of blood. To assess the marginal adaptation, “gap perimeter” and “maximum gap width” were measured under scanning electron microscope. The surface microstructure was also examined. Independent samples t-test and Mann-Whitney U test were used to analyze the data. Results. Maximum gap width and gap perimeter in the blood-exposed group were significantly larger than those in the STF-exposed group (p < 0.01. In the blood-exposed group, the crystals tended to be more rounded and less angular compared with the STF-exposed group, and there was a general lack of needle-like crystals. Conclusion. Exposure to blood during setting has a negative effect on marginal adaptation of MTA, and blood-exposed MTA has a different surface microstructure compared to STF-exposed MTA.

  3. Improving the safety of fresh fruit and vegetables

    NARCIS (Netherlands)

    Jongen, W.M.F.

    2005-01-01

    Fresh fruit and vegetables have been identified as a significant source of pathogens and chemical contaminants. As a result, there has been a wealth of research on identifying and controlling hazards at all stages in the supply chain. Improving the safety of fresh fruit and vegetables reviews this

  4. Accurate measurement of peripheral blood mononuclear cell concentration using image cytometry to eliminate RBC-induced counting error.

    Science.gov (United States)

    Chan, Leo Li-Ying; Laverty, Daniel J; Smith, Tim; Nejad, Parham; Hei, Hillary; Gandhi, Roopali; Kuksin, Dmitry; Qiu, Jean

    2013-02-28

    Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs

  5. Self-driven filter-based blood plasma separator microfluidic chip for point-of-care testing

    International Nuclear Information System (INIS)

    Madadi, Hojjat; Casals-Terré, Jasmina; Mohammadi, Mahdi

    2015-01-01

    There is currently a growing need for lab-on-a-chip devices for use in clinical analysis and diagnostics, especially in the area of patient care. The first step in most blood assays is plasma extraction from whole blood. This paper presents a novel, self-driven blood plasma separation microfluidic chip, which can extract more than 0.1 μl plasma from a single droplet of undiluted fresh human blood (∼5 μl). This volume of blood plasma is extracted from whole blood with high purity (more than 98%) in a reasonable time frame (3 to 5 min), and without the need for any external force. This would be the first step towards the realization of a single-use, self-blood test that does not require any external force or power source to deliver and analyze a fresh whole-blood sample, in contrast to the existing time-consuming conventional blood analysis. The prototypes are manufactured in polydimethylsiloxane that has been modified with a strong nonionic surfactant (Silwet L-77) to achieve hydrophilic behavior. The main advantage of this microfluidic chip design is the clogging delay in the filtration area, which results in an increased amount of extracted plasma (0.1 μl). Moreover, the plasma can be collected in one or more 10 μm-deep channels to facilitate the detection and readout of multiple blood assays. This high volume of extracted plasma is achieved thanks to a novel design that combines maximum pumping efficiency without disturbing the red blood cells’ trajectory through the use of different hydrodynamic principles, such as a constriction effect and a symmetrical filtration mode. To demonstrate the microfluidic chip’s functionality, we designed and fabricated a novel hybrid microdevice that exhibits the benefits of both microfluidics and lateral flow immunochromatographic tests. The performance of the presented hybrid microdevice is validated using rapid detection of thyroid stimulating hormone within a single droplet of whole blood. (paper)

  6. Blood flow determinations utilizing digital densitometry

    International Nuclear Information System (INIS)

    Lois, F.; Mankovich, N.J.; Gomes, A.S.

    1987-01-01

    A method of obtaining relative and absolute blood flow measurements from digital densitometry was evaluated with a simulated vessel phantom and a hydrodynamic model. A digital vascular imaging system capable of acquisition in 512 2 and 1024 2 mode was used. Relative and absolute blood flow were measured using parameters derived from the densitometric curve. Since application of densitometric data to absolute flow measurements requires the vessel diameter, an algorithm for vessel size determination was created. Gray scale changes were demonstrated to be linearly related to contrast concentration. The variance of vessel size determination was significantly different in all combinations of 1024 2 and 512 2 imaging with 15 cm or 35 cm field size. The error in vessel size determination was significantly less using the larger 1024 2 matrix and the smaller 15 cm image intensifier field size, as shown by the smaller variance. In relative flow determinations, there was good correlation between the flow and four parameters of the densitometric curve with no significant differences between 512 2 and 1024 2 imaging. Absolute flow determinations had slightly lower correlation to actual flow but were not significantly different from relative flow determinations. Relative and absolute blood flow determinations can be performed adequately with either 512 2 or 1024 2 imaging. The increased accuracy in vessel size determination with 1024 2 imaging makes this high resolution system potentially perferable to determine absolute blood flow. (orig.)

  7. Measurement of renal blood flow by 131I-labelled sodium iodohippurate imaging in a rat model of herpes encephalitis

    International Nuclear Information System (INIS)

    Cleator, G.M.; Klapper, P.E.; Lewis, A.G.; Sharma, H.L.; Smith, A.M.; Manchester Univ.

    1990-01-01

    Renal blood flow was assessed qualitatively over a 30 min period in a rat model of herpes encephalitis by extra-renal scintigraphic imaging following the injection of 131 I-labelled sodium iodohippurate. No significant differences were observed for renal blood flow in either kidney between (or within) infected and control groups. Our data suggest that kidney function is not compromised in this animal model of encephalitis. The results are discussed in the context of the development of a non-invasive protocol for the in vivo diagnosis of herpes encephalitis. (orig.)

  8. Blood and Blood Product Conservation: Results of Strategies to Improve Clinical Outcomes in Open Heart Surgery Patients at a Tertiary Hospital.

    Science.gov (United States)

    Khan, Junaid H; Green, Emily A; Chang, Jimmin; Ayala, Alexandria M; Barkin, Marilyn S; Reinys, Emily E; Stanton, Jeffrey; Stanten, Russell D

    2017-12-01

    Blood product usage is a quality outcome for patients undergoing cardiac surgery. To address an increase in blood product usage since the discontinuation of aprotinin, blood conservation strategies were initiated at a tertiary hospital in Oakland, CA. Improving transfusion rates for open heart surgery patients requiring Cardiopulmonary bypass (CPB) involved multiple departments in coordination. Specific changes to conserve blood product usage included advanced CPB technology upgrades, and precise individualized heparin dose response titration assay for heparin and protamine management. Retrospective analysis of blood product usage pre-implementation, post-CPB changes and post-Hemostasis Management System (HMS) implementation was done to determine the effectiveness of the blood conservation strategies. Statistically significant decrease in packed red blood cells, fresh frozen plasma, cryoprecipitate, and platelet usage over the stepped implementation of both technologies was observed. New oxygenator and centrifugal pump technologies reduced active circuitry volume and caused less damage to blood cells. Individualizing heparin and protamine dosing to a patient using the HMS led to transfusion reductions as well. Overall trends toward reductions in hospital length of stay and intensive care unit stay, and as a result, blood product cost and total hospitalization cost are positive over the period of implementation of both CPB circuit changes and HMS implementation. Although they are multifactorial in nature, these trends provide positive enforcement to the changes implemented.

  9. Preliminary Phytochemical Screening of Fresh and Dried Moringa ...

    African Journals Online (AJOL)

    The preliminary phytochemical screening of the crude aqueous extract of fresh and dried Moringa oleifera leaves, of the organic solvent and residual fractions of the extract was carried out according to the standard methods. Chemical constituents of the crude aqueous extract of the fresh leaves were found to be tannins, ...

  10. Preservation of fresh noodles by irradiation

    International Nuclear Information System (INIS)

    Cai Jianming

    1998-01-01

    At the present paper, it is studied to preserve fresh noodles by irradiation. The noodles which were irradiated by 10 kGy of 60 Co-γ rays and stored at room temperature (18-24 deg. C). The appearance of the noodles was observed, the bacteria in the noodles were examined, and the acidity of the noodles was measured during 10 days after irradiation. The results showed that the number of bacteria and the extent of acidification of the noodles were in inverse proportion to radiation dose. When the absorbed dose was less than 8 kGy, the residual bacteria in the noodles could proliferate massively in several days and acidified the noodles. The pH of these noodles decreased from 6.2 to 5.0 or less and the noodles turned into sticky during storage. When the absorbed dose reached 8-10 kGy, most of bacteria were killed and the acidity of the noodles kept about pH 6.0. The appearance of the noodles looks fresh within 10 days after irradiation. They smelled as good as fresh ones

  11. Elevation of the correlation between cerebral blood volume and permeability surface from CT perfusion images with glioma grade

    International Nuclear Information System (INIS)

    Ding Bei; Ling Huawei; Zhang Huan; Song Qi; Dong Haipeng; Chen Kemin

    2007-01-01

    Objective: To evaluate the correlation between cerebral blood volume and permeability surface by using multislice CT perfusion imaging with glioma grade. Methods: Ninteen patients with gliomas underwent conventional MR and multislice CT perfusion imaging preoperatively. These patients were divided into low grade and high grade groups which were correspond to WHO II grade gliomas and WHO III or IV grade gliomas respectively. CT data were transferred to on-line working station and processed to obtain time-signal curves, color perfusion maps and calculated perfusion parameters, including cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTF) and permeability surfaces (PS) in tumoral parenchyma. Kruskal-Wallis test and correlation of CBV and PS was assessed by using SPSS 11.0 software. Results: The median of CBV and PS in low-grade and high-grade glioma were 2.7, 6.5 ml/100 g; 0.389, 12.810 ml·100 g -1 ·min -1 respectively, corresponding t value were 12.907 13.500 with P<0.05. Pearson correlations between CBV and PS were as follows: in low-grade group, r=-0.058, in high-grade group, r=0.648. Conclusion: Both CBV and PS have obvious correlation with glioma grade. The correlation between CBV and PS in low-grade glioma was weaker, probably because of the focal high vascularity in oligodendroglioma. (authors)

  12. Effect of fresh air ventilation on indoor radon concentration

    International Nuclear Information System (INIS)

    Sun Hao; Wu Jianhua; Fu Shi

    2012-01-01

    The radon concentration of laboratory for radon simulation (LRS) was measured by the RAD7 radon monitor, and the effect of the different fresh air ventilations on indoor radon concentration was studied and analyzed. The indoor radon concentration of LRS can be accumulated up to 2000 Bq/m 3 and the average radon exhalation rate of the LRS is 14.5 Bq · m -2 . h -1 . Furthermore, when the fresh air enters into the LRS continuously, the indoor radon concentration decreases exponentially with the increase of time. The equilibrium radon concentration and equilibrium time of LRS decrease exponentially with the increase of the rate of fresh air ventilation. In addition, the indoor radon concentration increases by accumulation with the decrease of the rate of fresh air ventilation. (authors)

  13. Clinical comparison of cardiac blood pool visualization with technetium-99m red blood cells labeled in vivo and with technetium-99m human serum albumin

    International Nuclear Information System (INIS)

    Thrall, J.H.; Freitas, J.E.; Swanson, D.; Rogers, W.L.; Clare, J.M.; Brown, M.L.; Pitt, B.

    1978-01-01

    Technetium-99m red blood cells (Tc-RBC) labeled by an in vivo technique were compared with two preparations of Tc-99m human serum albumin (HSA) for cardiac blood-pool imaging. Relative distribution of the tracers was analyzed on end-diastolic frames of gated blood-pool studies and on whole-body (head to mid-thigh) anterior pinhole images. The Tc-RBC demonstrated greater relative percentage localization in the cardiac blood pool, higher target-to-background ratios in the left ventricle, and less liver concentration. For cardiac blood-pool imaging, Tc-RBC labeled by the in vivo approach appears to be superior to the two Tc-HSA preparations studied

  14. High quality methylome-wide investigations through next-generation sequencing of DNA from a single archived dry blood spot

    OpenAIRE

    Aberg, Karolina A.; Xie, Lin Y.; Nerella, Srilaxmi; Copeland, William E.; Costello, E. Jane; van den Oord, Edwin J.C.G.

    2013-01-01

    The potential importance of DNA methylation in the etiology of complex diseases has led to interest in the development of methylome-wide association studies (MWAS) aimed at interrogating all methylation sites in the human genome. When using blood as biomaterial for a MWAS the DNA is typically extracted directly from fresh or frozen whole blood that was collected via venous puncture. However, DNA extracted from dry blood spots may also be an alternative starting material. In the present study,...

  15. Effect of in vitro exposure to cadmium and copper on sea bass blood cells

    Directory of Open Access Journals (Sweden)

    Vincenzo Arizza

    2010-01-01

    Full Text Available Blood cells freshly collected from sea bass (Dicentrarchus labrax were exposed in vitro to different concentrations of cadmium (Cd and copper (Cu at 10-7 M, 10-5 M, 10-3 M, and exam- ined for neutral red retention capacity and for cell vitality with MTT assay. A relationship between heavy metal exposure and alteration in responses of blood cells in a dose-time-dependent was found. Our results showed that fish blood cells may constitute an interesting biological model for experimen- tal and applied toxicology, especially in the case of environmental pollution.

  16. [Value of intravoxel incoherent motion diffusion-weighted imaging in differential diagnosis of benign and malignant hepatic lesions and blood perfusion evaluation].

    Science.gov (United States)

    Ying, M L; Xiao, W W; Xu, S L; Shu, J E; Pan, J F; Fu, J F; Lu, J H; Pan, Y H; Jiang, Y

    2016-11-20

    Objective: To investigate the value of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in the differential diagnosis and blood perfusion evaluation of benign and malignant hepatic lesions. Methods: A retrospective analysis was performed for 86 patients (96 lesions) with pathologically or clinically confirmed hepatic lesions or hepatic lesions diagnosed based on follow-up results, among whom 48 had malignant lesions (53 lesions) and 38 had benign lesions (43 lesions). The patients underwent conventional magnetic resonance (MR) plain scan, contrast-enhanced scan, and diffusion-weighted imaging (DWI) with different b values (b = 0, 50, 100, 150, 200, 400, 600, 800, 1 000, and 1 200 s/mm 2 ) to determine the parameters of the double exponential model for intravoxel incoherent motion (IVIM): fast diffusion coefficient Dfast, slow diffusion coefficient Dslow, and percentage of fast-diffusion constituent F value. The patients were divided into groups according to the blood supply to lesions on conventional MR plain scan and contrast-enhanced scan, and there were 47 lesions in abundant blood supply group and 49 in poor blood supply group. The data for analysis were Dfast, Dslow, and F values of benign/malignant lesion groups and abundant/poor blood supply groups. The independent samples t-test was used for statistical analysis; the independent samples non-parametric test Mann-Whitney U test was used for the comparison of F value; the receiver operating characteristic (ROC) curve was used to evaluate the value of above parameters in the differentiation of benign and malignant lesions and blood supply evaluation. Results: Compared with the malignant lesion group, the benign lesion group had significantly higher Dslow, and F values ( P benign and malignant hepatic lesions, and F value can show blood perfusion in benign and malignant hepatic lesions without the need for contrast-enhanced scan, which provides a reference for the qualitative diagnosis of liver

  17. Examination of attenuation correction method for cerebral blood Flow SPECT Using MR imaging

    International Nuclear Information System (INIS)

    Mizuno, Takashi; Takahashi, Masaaki

    2009-01-01

    Authors developed a software for attenuation correction using MR imaging (MRAC) (Toshiba Med. System Engineer.) based on the idea that precision of AC could be improved by the head contour in MRI T2-weighted images (T2WI) obtained before 123 I-iofetamine (IMP) single photon emission computed tomography (SPECT) for cerebral blood flow (CBF) measurement. In the present study, this MRAC was retrospectively evaluated by comparison with the previous standard AC methods derived from transmission CT (TCT) and X-CT which overcoming the problem of sinogram threshold Chang method but still having cost and patient exposure issues. MRAC was essentially performed in the Toshiba GMS5500/PI processor where 3D registration was conducted with images of SPECT and MRI of the same patient. The gamma camera for 123 I-IMP SPECT and 99m TcO 4 - TCT was Toshiba 3-detector GCA9300A equipped with the above processor for MRAC and with low energy high resolution (LEHR) fan beam collimator. Machines for MRI and CT were Siemens-Asahi Meditech. MAGNETOM Symphony 1.5T and SOMATOM plus4, respectively. MRAC was examined in 8 patients with images of T1WI, TCT and SPECT, and in 18 of T2WI, CT and SPECT. Evaluation was made by comparison of attenuation coefficients (μ) by the 4 methods. As a result, the present MRAC was found to be closer to AC by TCT and CT than by the Chang method since MRAC, due to exact imaging of the head contour, was independent on radiation count, and was thought to be useful for improving the precision of CBF SPECT. (K.T.)

  18. White blood cell count - series (image)

    Science.gov (United States)

    ... the hand. The puncture site is cleaned with antiseptic, and a tourniquet (an elastic band) or blood ... or young child: The area is cleansed with antiseptic and punctured with a sharp needle or a ...

  19. Biochemical Basis of Fresh Ham Color Development

    OpenAIRE

    Stufft, Kristen Marie

    2015-01-01

    Commercial hams display variation in color uniformity across the cut surface, especially the semimembranosus (SM) muscle. This variation in fresh ham color, or two-toning, persists through further processing and contributes to production of a less desirable end product. In an attempt to understand the underlying source of this color variation, we evaluated the differences in muscle fiber-type composition and glycolytic metabolism in the SM muscle of fresh hams differing in color uniformity. F...

  20. Immersion technique as a tool for in-depth OCT imaging through human blood and body's interior tissues

    Science.gov (United States)

    Xu, Xiangqun; Tuchin, Valery V.; Wang, Ruikang K.

    2001-05-01

    The concept of refractive index matching used for the enhancement of optical penetration depth of the whole blood is discussed on the basis of in vitro studies using optical coherence tomography technique. It was found that blood optical clearing is defined not only by refractive index matching effect, but also by changes of RBC size and their aggregation ability when chemicals are added. Chemical agents studied include glycerol, propylene glycol, trazograph, and dextrans. For the hyperosmotic agents, the application of 6.5% glycerol into twice diluted blood reduces the total attenuation coefficient from 4.2/mm to 2.0/mm, and correspondingly increases the optical penetration at 820 nm up to 117%. Similar effects of increase in transmittance and decrease in light scattering are also demonstrated by various molecular detrans with the light penetration enhancement within a range between 52.1% and 150.5%. We also demonstrate that the use of biocompatible agents could enhance in-depth imaging of the human esophagus and stomach tissues.

  1. Factors influencing Consumer Preference for Fresh Beef in Sokoto ...

    African Journals Online (AJOL)

    SH

    selected and interviewed to identify factors that affect preference for fresh beef and to determine the nature of the ... preference are appreciated by the food ... composition and household income .... habit and flavor, made them to prefer fresh.

  2. Evaluating the pacemaker effect with the pump parameter of gated blood-pool imaging

    International Nuclear Information System (INIS)

    Cheng Muhua

    1995-01-01

    13 normal controls and 27 patients with ventricular pacemaker had undergone planar gated blood-pool imaging in different conditions. Result shows: (1) Pump parameters can successfully reflect therapeutic effect of pacemaker among them EMP is the most valuable parameter for evaluating the cardiac pumping effect. (2) After implantation of the ventricular pacemaker, the LVEF did not increase, but the CO and EMP was significantly increased. (3) Compared with right ventricular demand pacemaker, the rate-responsive ventricular pacemaker give better hemodynamic benefit at exercise condition. (4) Through restrained cardiac pacemaker the functional change was analyzed on or off pace, and monitoring the cardiac function itself after the pacemaker was implanted

  3. Modified atmosphere packaging of fresh meats : sudden partial adaption caused an increase in sustainability of Dutch supply chains of fresh meats

    NARCIS (Netherlands)

    Thoden Van Velzen, E.U.; Linnemann, A.R.

    2008-01-01

    In the past decade, a major transition evolved in the Dutch fresh meat industry with ramifications for the entire meat business. In 1995, more than 95% of all fresh meat products for consumers were either sold loose or packed in the traditional way, i.e. on a white styrofoam tray with stretch wrap.

  4. Sup(99m) Technetium - labeled red blood cells 'in vitro'

    International Nuclear Information System (INIS)

    Bernardo Filho, M.; Souza Moura, I.N. de; Boasquevisque, E.M.

    1983-01-01

    A simple technique for the preparation of sup(99m) Tc labeled red blood cells using a comercial kit is described. To each 3ml of plain blood with anti-coagulant was added 1ml of solution of commercial kit with 6.8 μg of stannous chloride. This mixture was incubated in water bath, at 37 0 C, for 60 minutes. Then technetium-99m was added and the mixture was left for another ten minutes, in water bath, at 37 0 C. Under these conditions there was the best labeling of the red blood cells. Similar results were obtained with a solution of stannous chloride prepared freshly. The labeling is strong for 6.8 μg stannous chloride because the labeling was not removed by the several washes of the red blood cells or by the left in water bath. (Author) [pt

  5. Freeze-all policy: fresh vs. frozen-thawed embryo transfer.

    Science.gov (United States)

    Roque, Matheus; Valle, Marcello; Guimarães, Fernando; Sampaio, Marcos; Geber, Selmo

    2015-05-01

    To compare in vitro fertilization (IVF) outcomes between fresh embryo transfer (ET) and frozen-thawed ET (the "freeze-all" policy), with fresh ET performed only in cases without progesterone (P) elevation. Prospective, observational, cohort study. Private IVF center. A total of 530 patients submitted to controlled ovarian stimulation (COS) with a gonadotropin-releasing hormone-antagonist protocol, and cleavage-stage, day-3 ET. None. Ongoing pregnancy rates. A total of 530 cycles were included in the analysis: 351 in the fresh ET group (when P levels were ≤1.5 ng/mL on the trigger day); and 179 cycles in the freeze-all group (ET performed after endometrial priming with estradiol valerate, at 6 mg/d, taken orally). For the fresh ET group vs. the freeze-all group, respectively, the implantation rate was 19.9% and 26.5%; clinical pregnancy rate was 35.9% and 46.4%; and ongoing pregnancy rate was 31.1% and 39.7%. The IVF outcomes were significantly better in the group using the freeze-all policy, compared with the group using fresh ET. These results suggest that even in a select group of patients that underwent fresh ET (P levels ≤1.5 ng/mL), endometrial receptivity may have been impaired by COS, and outcomes may be improved by using the freeze-all policy. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  6. Three-dimensional image reconstruction from stereo DSA

    International Nuclear Information System (INIS)

    Sakamoto, Kiyoshi; Kotoura, Noriko; Umehara, Takayoshi; Yamada, Eiji; Inaba, Tomohiro; Itou, Hiroshi

    1999-01-01

    The technique of interventional radiology has spread rapidly in recent years, and three-dimensional information from blood vessel images is being sought to enhance examinations. Stereo digital subtraction angiography (DSA) and rotational DSA were developed for that purpose. However, it is difficult with stereo DSA to observe the image pair during examination and to obtain positional information on blood vessels. Further, the exposure dose is increased in rotational DSA when many mask images need to be collected, and the patient is required to hold his or her breath for a long duration. We therefore devised a technique to construct three-dimensional blood vessel images by employing geometrical information extracted from stereo DSA images using the right and left images. We used a judgment method based on the correlation coefficient, although we had to extract an equal blood vessel from the right and left images to determine the three-dimensional coordinates of the blood vessel. The reconstructed three-dimensional blood vessels were projected from various angles, again by using a virtual focus, and new images were created. These image groups were displayed as rotational images by the animation display function incorporated in the DSA device. This system can observe blood vessel images of the same phase at a free angle, although the image quality is inferior to that of rotational DSA. In addition, because collection of the mask images is reduced, exposure dose can be decreased. Further, the system offers enhanced safety because no mechanical movement of the imaging system is involved. (author)

  7. Autologous blood injection to the temporomandibular joint: magnetic resonance imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Candirili, Celal; Yuece, Serdar; Cavus, Umut Yuecel; Akin, Kayihan; Cakir, Banu [Fatih University Hospital, Ankara (Turkmenistan)

    2012-03-15

    The aim of this study was to investigate the effect of the autologous blood injection (ABI) for chronic recurrent temporomandibular joint (TMJ) dislocation using magnetic resonance imaging (MRI). ABI was applied to 14 patients who had chronic recurrent TMJ dislocation. MRIs of the patients were taken and compared before and one month after the injection. All of the patients had no dislocations of their TMJs on clinical examination one month after the injection. In the pre-injection, unilateral or bilateral TMJ dislocations were observed on MRIs in all patients. One month after the injection, TMJ dislocations were not observed in MRI evaluation of any patients. A significant structural change that caused by ABI was not observed. The procedure was easy to perform and it caused no foreign body reaction. However, it was unclear how the procedure prevented the dislocation.

  8. DRAQ5 and Eosin ('D&E') as an Analog to Hematoxylin and Eosin for Rapid Fluorescence Histology of Fresh Tissues.

    Science.gov (United States)

    Elfer, Katherine N; Sholl, Andrew B; Wang, Mei; Tulman, David B; Mandava, Sree H; Lee, Benjamin R; Brown, J Quincy

    2016-01-01

    Real-time on-site histopathology review of biopsy tissues at the point-of-procedure has great potential for significant clinical value and improved patient care. For instance, on-site review can aid in rapid screening of diagnostic biopsies to reduce false-negative results, or in quantitative assessment of biospecimen quality to increase the efficacy of downstream laboratory and histopathology analysis. However, the only currently available rapid pathology method, frozen section analysis (FSA), is too time- and labor-intensive for use in screening large quantities of biopsy tissues and is too destructive for maximum tissue conservation in multiple small needle core biopsies. In this work we demonstrate the spectrally-compatible combination of the nuclear stain DRAQ5 and the anionic counterstain eosin as a dual-component fluorescent staining analog to hematoxylin and eosin intended for use on fresh, unsectioned tissues. Combined with optical sectioning fluorescence microscopy and pseudo-coloring algorithms, DRAQ5 and eosin ("D&E") enables very fast, non-destructive psuedohistological imaging of tissues at the point-of-acquisition with minimal tissue handling and processing. D&E was validated against H&E on a one-to-one basis on formalin-fixed paraffin-embedded and frozen section tissues of various human organs using standard epi-fluorescence microscopy, demonstrating high fidelity of the staining mechanism as an H&E analog. The method was then applied to fresh, whole 18G renal needle core biopsies and large needle core prostate biospecimen biopsies using fluorescence structured illumination optical sectioning microscopy. We demonstrate the ability to obtain high-resolution histology-like images of unsectioned, fresh tissues similar to subsequent H&E staining of the tissue. The application of D&E does not interfere with subsequent standard-of-care H&E staining and imaging, preserving the integrity of the tissue for thorough downstream analysis. These results indicate

  9. DRAQ5 and Eosin ('D&E' as an Analog to Hematoxylin and Eosin for Rapid Fluorescence Histology of Fresh Tissues.

    Directory of Open Access Journals (Sweden)

    Katherine N Elfer

    Full Text Available Real-time on-site histopathology review of biopsy tissues at the point-of-procedure has great potential for significant clinical value and improved patient care. For instance, on-site review can aid in rapid screening of diagnostic biopsies to reduce false-negative results, or in quantitative assessment of biospecimen quality to increase the efficacy of downstream laboratory and histopathology analysis. However, the only currently available rapid pathology method, frozen section analysis (FSA, is too time- and labor-intensive for use in screening large quantities of biopsy tissues and is too destructive for maximum tissue conservation in multiple small needle core biopsies. In this work we demonstrate the spectrally-compatible combination of the nuclear stain DRAQ5 and the anionic counterstain eosin as a dual-component fluorescent staining analog to hematoxylin and eosin intended for use on fresh, unsectioned tissues. Combined with optical sectioning fluorescence microscopy and pseudo-coloring algorithms, DRAQ5 and eosin ("D&E" enables very fast, non-destructive psuedohistological imaging of tissues at the point-of-acquisition with minimal tissue handling and processing. D&E was validated against H&E on a one-to-one basis on formalin-fixed paraffin-embedded and frozen section tissues of various human organs using standard epi-fluorescence microscopy, demonstrating high fidelity of the staining mechanism as an H&E analog. The method was then applied to fresh, whole 18G renal needle core biopsies and large needle core prostate biospecimen biopsies using fluorescence structured illumination optical sectioning microscopy. We demonstrate the ability to obtain high-resolution histology-like images of unsectioned, fresh tissues similar to subsequent H&E staining of the tissue. The application of D&E does not interfere with subsequent standard-of-care H&E staining and imaging, preserving the integrity of the tissue for thorough downstream analysis

  10. Pharmacodynamic correlations using fresh and cryopreserved tissue following use of vaginal rings containing dapivirine and/or maraviroc in a randomized, placebo controlled trial.

    Science.gov (United States)

    Dezzutti, Charlene S; Richardson-Harman, Nicola; Rohan, Lisa C; Marzinke, Mark A; Hoesley, Craig J; Panther, Lori; Johnson, Sherri; Nuttall, Jeremy P; Nel, Annalene; Chen, Beatrice A

    2016-07-01

    The ex vivo challenge assay is a bio-indicator of drug efficacy and was utilized in this randomized, placebo controlled trial as one of the exploratory endpoints. Fresh and cryopreserved tissues were evaluated for human immunodeficiency virus (HIV) infection and pharmacokinetic (PK)/pharmacodynamic (PD) relationships. HIV-negative women used vaginal rings containing 25 mg dapivirine (DPV)/100 mg maraviroc (MVC) (n = 12), DPV only (n = 12), MVC only (n = 12), or placebo (n = 12) for 28 days. Blood plasma, cervicovaginal fluid (CVF), and cervical biopsies were collected for drug quantification and the ex vivo challenge assay; half (fresh) were exposed immediately to HIV while the other half were cryopreserved, thawed, then exposed to HIV. HIV replication was monitored by p24 enzyme-linked immunosorbent assay from culture supernatant. Data were log-transformed and analyzed by linear least squared regression, nonlinear Emax dose-response model and Satterthwaite t test. HIV replication was greater in fresh compared to cryopreserved tissue (P = 0.04). DPV was detected in all compartments, while MVC was consistently detected only in CVF. Significant negative correlations between p24 and DPV levels were observed in fresh cervical tissue (P = 0.01) and CVF (P = 0.03), but not plasma. CVF MVC levels showed a significant negative correlation with p24 levels (P = 0.03); drug levels in plasma and tissue were not correlated with HIV suppression. p24 levels from cryopreserved tissue did not correlate to either drug from any compartment. Fresh tissue replicated HIV to greater levels and defined PK/PD relationships while cryopreserved tissue did not. The ex vivo challenge assay using fresh tissue could prioritize drugs being considered for HIV prevention.

  11. Image averaging for angiography by registration and combination of serial images

    International Nuclear Information System (INIS)

    Brooks, S.H.; Selzer, R.H.; Crawford, D.W.; Blankenhorn, D.H.

    1982-01-01

    In order to increase the contrast of x-ray images of artery edges, a method is disclosed whereby a contrast medium opaque to x-rays in injected into a blood vessel distant from an artery section of interest. Mulitple x-ray images are obtained as the contrast medium and blood mixture flows through the artery section. These images are registered with a landmark within the patient. Density measurements are made with respect to each corresponding image segment and are combined to synthesize a composite image of the edge of the artery section

  12. Leontief Input-Output Method for The Fresh Milk Distribution Linkage Analysis

    Directory of Open Access Journals (Sweden)

    Riski Nur Istiqomah

    2016-11-01

    Full Text Available This research discusses about linkage analysis and identifies the key sector in the fresh milk distribution using Leontief Input-Output method. This method is one of the application of Mathematics in economy. The current fresh milk distribution system includes dairy farmers →collectors→fresh milk processing industries→processed milk distributors→consumers. Then, the distribution is merged between the collectors’ axctivity and the fresh milk processing industry. The data used are primary and secondary data taken in June 2016 in Kecamatan Jabung Kabupaten Malang. The collected data are then analysed using Leontief Input-Output Matriks and Python (PYIO 2.1 software. The result is that the merging of the collectors’ and the fresh milk processing industry’s activities shows high indices of forward linkages and backward linkages. It is shown that merging of the two activities is the key sector which has an important role in developing the whole activities in the fresh milk distribution.

  13. The effects of aprotinin on blood product transfusion associated with thoracic aortic surgery requiring deep hypothermic circulatory arrest.

    LENUS (Irish Health Repository)

    Seigne, P W

    2012-02-03

    OBJECTIVE: To compare the effects of aprotinin on blood product use and postoperative complications in patients undergoing thoracic aortic surgery requiring deep hypothermic circulatory arrest. DESIGN: A retrospective study. SETTING: A university hospital. PARTICIPANTS: Nineteen patients who underwent elective or urgent thoracic aortic surgery. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The total number of units of packed red blood cells, fresh frozen plasma, and platelets was significantly less in the group that received aprotinin (p = 0.01, 0.04, and 0.01). The intraoperative transfusion of packed red blood cells and platelets, collection and retransfusion of cell saver, and postoperative transfusion of fresh frozen plasma were also significantly less in the aprotinin group (p = 0.01, 0.02, 0.01, and 0.05). No patient in either group sustained renal dysfunction or a myocardial infarction. Two patients who had not received aprotinin suffered from chronic postoperative seizures, and one patient who had received aprotinin sustained a perioperative stroke. CONCLUSIONS: Low-dose aprotinin administration significantly decreases blood product transfusion requirements in the setting of thoracic aortic surgery requiring deep hypothermic circulatory arrest, and it does not appear to be associated with renal or myocardial dysfunction.

  14. Maintained functionality of an implantable radiotelemetric blood pressure and heart rate sensor after magnetic resonance imaging in rats

    International Nuclear Information System (INIS)

    Nölte, I; Boll, H; Figueiredo, G; Groden, C; Brockmann, M A; Gorbey, S; Lemmer, B

    2011-01-01

    Radiotelemetric sensors for in vivo assessment of blood pressure and heart rate are widely used in animal research. MRI with implanted sensors is regarded as contraindicated as transmitter malfunction and injury of the animal may be caused. Moreover, artefacts are expected to compromise image evaluation. In vitro, the function of a radiotelemetric sensor (TA11PA-C10, Data Sciences International) after exposure to MRI up to 9.4 T was assessed. The magnetic force of the electromagnetic field on the sensor as well as radiofrequency (RF)-induced sensor heating was analysed. Finally, MRI with an implanted sensor was performed in a rat. Imaging artefacts were analysed at 3.0 and 9.4 T ex vivo and in vivo. Transmitted 24 h blood pressure and heart rate were compared before and after MRI to verify the integrity of the telemetric sensor. The function of the sensor was not altered by MRI up to 9.4 T. The maximum force exerted on the sensor was 273 ± 50 mN. RF-induced heating was ruled out. Artefacts impeded the assessment of the abdomen and thorax in a dead rat, but not of the head and neck. MRI with implanted radiotelemetric sensors is feasible in principal. The tested sensor maintains functionality up to 9.4 T. Artefacts hampered abdominal and throacic imaging in rats, while assessment of the head and neck is possible

  15. Image acquisition and interpretation criteria for Tc-99m-HMPAO-labelled white blood cell scintigraphy : results of a multicentre study

    NARCIS (Netherlands)

    Erba, Paola A.; Glaudemans, Andor W. J. M.; Veltman, Niels C.; Sollini, Martina; Pacilio, Marta; Galli, Filippo; Dierckx, Rudi A. J. O.; Signore, Alberto

    Purpose There is no consensus yet on the best protocol for planar image acquisition and interpretation of radiolabelled white blood cell (WBC) scintigraphy. This may account for differences in reported diagnostic accuracy amongst different centres. Methods This was a multicentre retrospective study

  16. Comprehensive MRA of the lower limbs including high-resolution extended-phase infra-inguinal imaging with gadobenate dimeglumine: Initial experience with inter-individual comparison to the blood-pool contrast agent gadofosveset trisodium

    International Nuclear Information System (INIS)

    Christie, A.; Chandramohan, S.; Roditi, G.

    2013-01-01

    Aim: To compare extended-phase imaging using an extracellular space contrast agent, gadobenate dimeglumine, to imaging with a blood-pool contrast agent, gadofosveset, for magnetic resonance angiography. Materials and methods: A lower-limb magnetic resonance angiography (MRA) protocol (dynamic crural, three-station bolus chase, and infra-inguinal high resolution) designed for blood-pool agent imaging was adapted for use with the extracellular agent, gadobenate dimeglumine, primarily by using a triphasic injection protocol. Ten patients scanned with gadofosveset were compared to 10 patients scanned with gadobenate. The dynamic, bolus chase, and high-resolution images were scored for quality on a Likert scale (from 1–5). Signal- and contrast-to-noise ratios were analysed, and Mann–Whitney U statistical analysis performed. Results: There was no significant difference for the dynamic imaging or the aorto-iliac station of the bolus chase. Infra-inguinal bolus chase images were higher quality (p < 0.05 Mann–Whitney U test) with gadobenate. Signal analysis confirmed lower signal and contrast for venous imaging on the high spatial resolution acquisitions with gadobenate; however, this allowed improved arterial conspicuity. Conclusion: Extended-phase imaging using an extracellular space contrast agent is feasible and provides image quality to equal imaging with a blood-pool contrast agent.

  17. Segmentation of White Blood Cells From Microscopic Images Using a Novel Combination of K-Means Clustering and Modified Watershed Algorithm.

    Science.gov (United States)

    Ghane, Narjes; Vard, Alireza; Talebi, Ardeshir; Nematollahy, Pardis

    2017-01-01

    Recognition of white blood cells (WBCs) is the first step to diagnose some particular diseases such as acquired immune deficiency syndrome, leukemia, and other blood-related diseases that are usually done by pathologists using an optical microscope. This process is time-consuming, extremely tedious, and expensive and needs experienced experts in this field. Thus, a computer-aided diagnosis system that assists pathologists in the diagnostic process can be so effective. Segmentation of WBCs is usually a first step in developing a computer-aided diagnosis system. The main purpose of this paper is to segment WBCs from microscopic images. For this purpose, we present a novel combination of thresholding, k-means clustering, and modified watershed algorithms in three stages including (1) segmentation of WBCs from a microscopic image, (2) extraction of nuclei from cell's image, and (3) separation of overlapping cells and nuclei. The evaluation results of the proposed method show that similarity measures, precision, and sensitivity respectively were 92.07, 96.07, and 94.30% for nucleus segmentation and 92.93, 97.41, and 93.78% for cell segmentation. In addition, statistical analysis presents high similarity between manual segmentation and the results obtained by the proposed method.

  18. Red Tides: Mass casualty and whole blood at sea Red Tides.

    Science.gov (United States)

    Miller, Benjamin T; Lin, Andrew H; Clark, Susan C; Cap, Andrew P; Dubose, Joseph J

    2018-02-13

    The U.S. Navy's casualty-receiving ships provide remote damage control resuscitation (RDCR) platforms to treat injured combatants deployed afloat and ashore. We report a significant mass casualty incident aboard the USS Bataan, and the most warm fresh whole blood (WFWB) transfused at sea for traumatic hemorrhagic shock since the Vietnam War. Casualty-receiving ships have robust medical capabilities, including a frozen blood bank with packed red blood cells (pRBC) and fresh frozen plasma (FFP). The blood supply can be augmented with WFWB collected from a "walking blood bank" (WBB). Following a helicopter crash, six patients were transported by MV-22 Osprey to the USS Bataan. Patient 1 had a pelvic fracture, was managed with a pelvic binder, and received 4 units of pRBC, 2 units of FFP, and 6 units of WFWB. Patient 2, with a comminuted tibia and fibula fracture, underwent lower extremity four-compartment fasciotomy, and received 4 units of WFWB. Patient 3 underwent several procedures, including left anterior thoracotomy, aortic cross-clamping, exploratory laparotomy, small bowel resection, and tracheostomy. He received 8 units of pRBC, 8 units of FFP, and 28 units of WFWB. Patients 4 and 5 had suspected spine injuries and were managed non-operatively. Patient 6, with open tibia and fibula fractures, underwent lower extremity four-compartment fasciotomy with tibia external fixation and received 1 unit of WFWB. All patients survived aeromedical evacuation to a Role 4 medical facility and subsequent transfer to local hospitals. Maritime military mass casualty incidents are challenging, but the U.S. Navy's casualty-receiving ships are ready to perform RDCR at sea. Activation of the ship's WBB to transfuse WFWB is essential for hemostatic resuscitations afloat. V STUDY TYPE: Case series.

  19. 7 CFR 457.129 - Fresh market sweet corn crop insurance provisions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Fresh market sweet corn crop insurance provisions. 457... sweet corn crop insurance provisions. The fresh market sweet corn crop insurance provisions for the 2008... Reinsured Policies Fresh Market Sweet Corn Crop Provisions 1. Definitions Allowable cost.—The dollar amount...

  20. Pasteurization and radiation of fresh milk

    International Nuclear Information System (INIS)

    Sjarief, Sri Hariani

    1976-01-01

    In this investigation, treatments with pasteurization and irradiation with gamma rays on fresh milk were used. Pasteurization was done at temperatures of 62 deg C and 70 deg C. The irradiation doses used were 100, 200, 300, 400, 500 and 600 krad. The results of the investigation showed that the number of bacteria decreased after either pasteurization or irradiation. The higher the dose of irradiation the lower the total bacterial counts in milk became, but the latter increased during storage at 10 deg C. The number of bacteria in pasteurized milk did not show any significant difference from milk irradiated with the dose of 300-600 krad after 15 days of storage in the refrigerator. No enzymatic activity was detected in pasteurized milk, but after storage the coli bacteria acivity tested to become positive in the MPN test. On the countrary irradiation of fresh milk could stimulate the enzymatic activity, although the protein content was constant. Finally, heating as a pretreatment is better to be used before pasteurizing or sterilizing milk with ionizing radiation in order to preserve fresh milk for a longer period without any changes in the nutritional quality and taste. (author)

  1. Preservation of fresh avocados by irradiation

    International Nuclear Information System (INIS)

    Karmelic, J.

    1985-01-01

    Avocado is the fifth most important fruit in Chile, which exports fruits to Europe. The production of avocado has increased from 14,000 metric tons in 1978 to a projected 70,000 metric tons in 1985. The main problem of shipping fresh Chilean avocado to Europe has been its short shelf life, being around 24 days with a maximum of 30 days. To market fresh Chilean avocados in Europe, adequate keeping quality must be assured for 40 or more days. A project on the preservation of fresh Chilean avocados supported by the International Atomic Energy Agency (IAEA) takes the approach of combining mild heat and low-dose gamma-radiation. Two varieties of avocados were studied (Hass and Fuerte) and two batches of each were treated: one at the beginning and the other at the end of the picking season. In each case a combination of heat treatment (46 0 C for 10 minutes) and irradiation was applied. Fruits were individually wrapped with flexible PVC and placed in cardboard boxes containing 20 each. Fruits treated with 25,50, and 100 Gy were compared with two controls: one with and another without individual wrapping

  2. Fragile X protein in newborn dried blood spots.

    Science.gov (United States)

    Adayev, Tatyana; LaFauci, Giuseppe; Dobkin, Carl; Caggana, Michele; Wiley, Veronica; Field, Michael; Wotton, Tiffany; Kascsak, Richard; Nolin, Sarah L; Glicksman, Anne; Hosmer, Nicole; Brown, W Ted

    2014-10-28

    The fragile X syndrome (FXS) results from mutation of the FMR1 gene that prevents expression of its gene product, FMRP. We previously characterized 215 dried blood spots (DBS) representing different FMR1 genotypes and ages with a Luminex-based immunoassay (qFMRP). We found variable FMRP levels in the normal samples and identified affected males by the drastic reduction of FMRP. Here, to establish the variability of expression of FMRP in a larger random population we quantified FMRP in 2,000 anonymous fresh newborn DBS. We also evaluated the effect of long term storage on qFMRP by retrospectively assaying 74 aged newborn DBS that had been stored for 7-84 months that included normal and full mutation individuals. These analyses were performed on 3 mm DBS disks. To identify the alleles associated with the lowest FMRP levels in the fresh DBS, we analyzed the DNA in the samples that were more than two standard deviations below the mean. Analysis of the fresh newborn DBS revealed a broad distribution of FMRP with a mean approximately 7-fold higher than that we previously reported for fresh DBS in normal adults and no samples whose FMRP level indicated FXS. DNA analysis of the lowest FMRP DBS showed that this was the low extreme of the normal range and included a female carrying a 165 CGG repeat premutation. In the retrospective study of aged newborn DBS, the FMRP mean of the normal samples was less than 30% of the mean of the fresh DBS. Despite the degraded signal from these aged DBS, qFMRP identified the FXS individuals. The assay showed that newborn DBS contain high levels of FMRP that will allow identification of males and potentially females, affected by FXS. The assay is also an effective screening tool for aged DBS stored for up to four years.

  3. Quantitative phase imaging characterization of tumor-associated blood vessel formation on a chip

    Science.gov (United States)

    Guo, Peng; Huang, Jing; Moses, Marsha A.

    2018-02-01

    Angiogenesis, the formation of new blood vessels from existing ones, is a biological process that has an essential role in solid tumor growth, development, and progression. Recent advances in Lab-on-a-Chip technology has created an opportunity for scientists to observe endothelial cell (EC) behaviors during the dynamic process of angiogenesis using a simple and economical in vitro platform that recapitulates in vivo blood vessel formation. Here, we use quantitative phase imaging (QPI) microscopy to continuously and non-invasively characterize the dynamic process of tumor cell-induced angiogenic sprout formation on a microfluidic chip. The live tumor cell-induced angiogenic sprouts are generated by multicellular endothelial sprouting into 3 dimensional (3D) Matrigel using human umbilical vein endothelial cells (HUVECs). By using QPI, we quantitatively measure a panel of cellular morphological and behavioral parameters of each individual EC participating in this sprouting. In this proof-of-principle study, we demonstrate that QPI is a powerful tool that can provide real-time quantitative analysis of biological processes in in vitro 3D biomimetic devices, which, in turn, can improve our understanding of the biology underlying functional tissue engineering.

  4. Non-gated fetal MRI of umbilical blood flow in an acardiac twin

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Nobuhiko [University of Tokyo, Graduate School of Information Science and Technology, Tokyo (Japan); Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Wada, Toru [University of Tokyo, Graduate School of Information Science and Technology, Tokyo (Japan); Kashima, Kyoko; Okada, Yoshiyuki [National Center for Child Health and Development, Department of Radiology, Tokyo (Japan); Unno, Nobuya [Nagano Children' s Hospital, Center for Perinatal Medicine, Nagano (Japan); Kitagawa, Michihiro [National Center for Child Health and Development, Department of Prenatal Medicine and Maternal Care, Tokyo (Japan); Chiba, Toshio [National Center for Child Health and Development, Department of Strategic Medicine, Tokyo (Japan)

    2005-08-01

    Currently, the standard method of diagnosis of twin reversed arterial perfusion (TRAP) sequence is ultrasound imaging. The use of MRI for flow visualization may be a useful adjunct to US imaging for assessing the presence of retrograde blood flow in the acardiac fetus and/or umbilical artery. The technical challenge in fetal MRI flow imaging, however, is that fetal electrocardiogram (ECG) monitoring required for flow imaging is currently unavailable in the MRI scanner. A non-gated MRI flow imaging technique that requires no ECG monitoring was developed using the t-test to detect blood flow in 20 slices of phase-contrast MRI images randomly scanned at the same location over multiple cardiac cycles. A feasibility study was performed in a 24-week acardiac twin that showed no umbilical flow sonographically. Non-gated MRI flow images clearly indicated the presence of blood flow in the umbilical artery to the acardiac twin; however, there was no blood flow beyond the abdomen. This study leads us to conjecture that non-gated MRI flow imaging is sensitive in detecting low-range blood flow velocity and can be an adjunct to Doppler US imaging. (orig.)

  5. Non-gated fetal MRI of umbilical blood flow in an acardiac twin

    International Nuclear Information System (INIS)

    Hata, Nobuhiko; Wada, Toru; Kashima, Kyoko; Okada, Yoshiyuki; Unno, Nobuya; Kitagawa, Michihiro; Chiba, Toshio

    2005-01-01

    Currently, the standard method of diagnosis of twin reversed arterial perfusion (TRAP) sequence is ultrasound imaging. The use of MRI for flow visualization may be a useful adjunct to US imaging for assessing the presence of retrograde blood flow in the acardiac fetus and/or umbilical artery. The technical challenge in fetal MRI flow imaging, however, is that fetal electrocardiogram (ECG) monitoring required for flow imaging is currently unavailable in the MRI scanner. A non-gated MRI flow imaging technique that requires no ECG monitoring was developed using the t-test to detect blood flow in 20 slices of phase-contrast MRI images randomly scanned at the same location over multiple cardiac cycles. A feasibility study was performed in a 24-week acardiac twin that showed no umbilical flow sonographically. Non-gated MRI flow images clearly indicated the presence of blood flow in the umbilical artery to the acardiac twin; however, there was no blood flow beyond the abdomen. This study leads us to conjecture that non-gated MRI flow imaging is sensitive in detecting low-range blood flow velocity and can be an adjunct to Doppler US imaging. (orig.)

  6. Quantitative myocardial blood flow imaging with integrated time-of-flight PET-MR.

    Science.gov (United States)

    Kero, Tanja; Nordström, Jonny; Harms, Hendrik J; Sörensen, Jens; Ahlström, Håkan; Lubberink, Mark

    2017-12-01

    The use of integrated PET-MR offers new opportunities for comprehensive assessment of cardiac morphology and function. However, little is known on the quantitative accuracy of cardiac PET imaging with integrated time-of-flight PET-MR. The aim of the present work was to validate the GE Signa PET-MR scanner for quantitative cardiac PET perfusion imaging. Eleven patients (nine male; mean age 59 years; range 46-74 years) with known or suspected coronary artery disease underwent 15 O-water PET scans at rest and during adenosine-induced hyperaemia on a GE Discovery ST PET-CT and a GE Signa PET-MR scanner. PET-MR images were reconstructed using settings recommended by the manufacturer, including time-of-flight (TOF). Data were analysed semi-automatically using Cardiac VUer software, resulting in both parametric myocardial blood flow (MBF) images and segment-based MBF values. Correlation and agreement between PET-CT-based and PET-MR-based MBF values for all three coronary artery territories were assessed using regression analysis and intra-class correlation coefficients (ICC). In addition to the cardiac PET-MR reconstruction protocol as recommended by the manufacturer, comparisons were made using a PET-CT resolution-matched reconstruction protocol both without and with TOF to assess the effect of time-of-flight and reconstruction parameters on quantitative MBF values. Stress MBF data from one patient was excluded due to movement during the PET-CT scanning. Mean MBF values at rest and stress were (0.92 ± 0.12) and (2.74 ± 1.37) mL/g/min for PET-CT and (0.90 ± 0.23) and (2.65 ± 1.15) mL/g/min for PET-MR (p = 0.33 and p = 0.74). ICC between PET-CT-based and PET-MR-based regional MBF was 0.98. Image quality was improved with PET-MR as compared to PET-CT. ICC between PET-MR-based regional MBF with and without TOF and using different filter and reconstruction settings was 1.00. PET-MR-based MBF values correlated well with PET-CT-based MBF values and

  7. The effects of intraoperative autologous whole blood sequestration on the need for transfusion of allogenic blood and blood products in coronary bypass operations.

    Science.gov (United States)

    Canver, C C; Kroncke, G M; Nichols, R D; Murray, E L; Mentzer, R M

    1995-10-01

    We investigated the effect of intraoperative autologous blood sequestration (IABS), an old blood conservation method, on transfusion requirements for homologous packed red blood cells (PRBC), platelets, and fresh frozen plasma (FFP) for patients undergoing coronary bypass surgery. This non-randomized retrospective study involved 204 patients who underwent isolated primary coronary artery bypass grafting (CABG). In 140 patients (IABS Group), autologous heparinized whole blood was removed intraoperatively via aortic cannula before bypass and retransfused at the conclusion of extracorporeal circulation. In 64 control patients, no IABS was performed. Demographic characteristics and operative and perioperative variables for both groups were similar (p > 0.05). In 140 patients, the mean sequestered blood volume was 1430 ml (range = 700-2100 ml). The banked PRBC requirement during hospitalization was 1.91 units in the No IABS Group and 2.25 units for the IABS Group (p = 0.2957). The need for platelet transfusion was 3.06 units in the No IABS Group and 1.09 units in the IABS Group (p = 0.0003). In the No IABS Group, 1.31 units of FFP was transfused and in the IABS Group, 0.49 units was transfused (p = 0.0004). To identify possible confounding factors, we performed a multivariate Poisson regression analysis for the 22 patient variables by a forward stepwise procedure. Regression analysis indicated that IABS did not alter the need for PRBC transfusion (p = 0.6194) but adjusted differences did confirm that IABS was associated with decreased need for transfusion of platelets and FFP (p = 0.0001 and p = 0.0002, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Investigations of new cardiac functional imaging using Fourier analysis of gated blood-pool study

    International Nuclear Information System (INIS)

    Maeda, H.; Takeda, K.; Nakagawa, T.; Yamaguchi, N.; Taguchi, M.; Konishi, T.; Hamada, M.

    1982-01-01

    A new cardiac functional imaging, using temporal Fourier analysis of 28-frame gated cardiac blood-pool studies, was developed. A time-activity curve of each pixel was approximated by its Fourier series. Approximation by the sum for terms to the 3rd frequency of its Fourier series was considered to be most reasonable because of having the least aberration due to statistical fluctuation and close agreement between the global left ventricular curve and the regional fitted curves in normal subjects. To evaluate the ventricular systolic and diastolic performances, 9 parameters were analyzed from thus fitted curves on a pixel-by-pixel basis and displayed on a colour CRT in 64x64 matrix form. In patients with hypertrophic obstructive cardiomyopathy and other cardiac lesions, detailed information on the regional ventricular systolic and diastolic performances was clearly visualized by this method, which was difficult to obtain from the usual functional images of phase and amplitude at the fundamental frequency alone

  9. Hot water, fresh beer, and salt

    International Nuclear Information System (INIS)

    Crawford, F.S.

    1990-01-01

    In the ''hot chocolate effect'' the best musical scales (those with the finest tone quality, largest range, and best tempo) are obtained by adding salt to a glass of hot water supersaturated with air. Good scales can also be obtained by adding salt to a glass of freshly opened beer (supersaturated with CO 2 ) provided you first (a) get rid of much of the excess CO 2 so as to produce smaller, hence slower, rising bubbles, and (b) get rid of the head of foam, which damps the standing wave and ruins the tone quality. Finally the old question, ''Do ionizing particles produce bubbles in fresh beer?'' is answered experimentally

  10. Hot water, fresh beer, and salt

    Science.gov (United States)

    Crawford, Frank S.

    1990-11-01

    In the ``hot chocolate effect'' the best musical scales (those with the finest tone quality, largest range, and best tempo) are obtained by adding salt to a glass of hot water supersaturated with air. Good scales can also be obtained by adding salt to a glass of freshly opened beer (supersaturated with CO2) provided you first (a) get rid of much of the excess CO2 so as to produce smaller, hence slower, rising bubbles, and (b) get rid of the head of foam, which damps the standing wave and ruins the tone quality. Finally the old question, ``Do ionizing particles produce bubbles in fresh beer?'' is answered experimentally.

  11. Intelligent color vision system for ripeness classification of oil palm fresh fruit bunch.

    Science.gov (United States)

    Fadilah, Norasyikin; Mohamad-Saleh, Junita; Abdul Halim, Zaini; Ibrahim, Haidi; Syed Ali, Syed Salim

    2012-10-22

    Ripeness classification of oil palm fresh fruit bunches (FFBs) during harvesting is important to ensure that they are harvested during optimum stage for maximum oil production. This paper presents the application of color vision for automated ripeness classification of oil palm FFB. Images of oil palm FFBs of type DxP Yangambi were collected and analyzed using digital image processing techniques. Then the color features were extracted from those images and used as the inputs for Artificial Neural Network (ANN) learning. The performance of the ANN for ripeness classification of oil palm FFB was investigated using two methods: training ANN with full features and training ANN with reduced features based on the Principal Component Analysis (PCA) data reduction technique. Results showed that compared with using full features in ANN, using the ANN trained with reduced features can improve the classification accuracy by 1.66% and is more effective in developing an automated ripeness classifier for oil palm FFB. The developed ripeness classifier can act as a sensor in determining the correct oil palm FFB ripeness category.

  12. Intelligent Color Vision System for Ripeness Classification of Oil Palm Fresh Fruit Bunch

    Directory of Open Access Journals (Sweden)

    Haidi Ibrahim

    2012-10-01

    Full Text Available Ripeness classification of oil palm fresh fruit bunches (FFBs during harvesting is important to ensure that they are harvested during optimum stage for maximum oil production. This paper presents the application of color vision for automated ripeness classification of oil palm FFB. Images of oil palm FFBs of type DxP Yangambi were collected and analyzed using digital image processing techniques. Then the color features were extracted from those images and used as the inputs for Artificial Neural Network (ANN learning. The performance of the ANN for ripeness classification of oil palm FFB was investigated using two methods: training ANN with full features and training ANN with reduced features based on the Principal Component Analysis (PCA data reduction technique. Results showed that compared with using full features in ANN, using the ANN trained with reduced features can improve the classification accuracy by 1.66% and is more effective in developing an automated ripeness classifier for oil palm FFB. The developed ripeness classifier can act as a sensor in determining the correct oil palm FFB ripeness category.

  13. TRANSFUSION RESTORES BLOOD VISCOSITY AND REINSTATES MICROVASCULAR CONDITIONS FROM HEMORRHAGIC SHOCK INDEPENDENT OF OXYGEN CARRYING CAPACITY

    OpenAIRE

    Cabrales, Pedro; Intaglietta, Marcos; Tsai, Amy G.

    2007-01-01

    Systemic and microvascular hemodynamic responses to transfusion of oxygen using functional and non-functional packed fresh red blood cells (RBCs) from hemorrhagic shock were studied in the hamster window chamber model to determine the significance of RBCs on rheological and oxygen transport properties. Moderate hemorrhagic shock was induced by arterial controlled bleeding of 50% of the blood volume, and a hypovolemic state was maintained for one hour. Volume restitution was performed by infus...

  14. Tracking blood vessels in human forearms using visual servoing

    DEFF Research Database (Denmark)

    Savarimuthu, Thiusius Rajeeth; Ellekilde, Lars-Peter; Hansen, Morten

    compensation. By using images taken with near-infrared light to locate the blood vessels in a human forearm and using the same images to detects movements of the arm, this paper shows that it is possible make a robot arm, potentially equipped with a needle for drawing the blood, compensate for the movements......Drawing an average of more than 2 blood sample per Danish citizen per year increases the demand for an automatic blood sampling method. This paper presents a proof of concept to one of the main challenges in making a fully automated blood sampling procedure, namely: the patient movement...

  15. Oxygen affinity and Bohr effect responses to 2,3-diphosphoglycerate in equine and human blood.

    Science.gov (United States)

    diBella, G; Scandariato, G; Suriano, O; Rizzo, A

    1996-05-01

    The dependence of blood oxygen affinity and the Bohr effect on the concentration of 2,3-diphosphoglycerate (DPG) in erythrocytes was investigated in 24 trotter horses and 24 healthy men. The oxygen tension at half saturation and standard conditions (P50st at pH 7.4, PCO2(40) mmHg and 37 degrees C) and the carbon dioxide or fixed-acid-induced Bohr effect (dlogP50/dpH) were determined. Samples of fresh blood and blood depleted of or enriched with DPG were studied. In the absence of measurable DPG, the equine and human blood had similar mean (SD) values of P50st (16.6 [0.6] and 16.2 [0.7] mmHg, respectively). In both species these values increased with increasing DPG, but the response of equine blood was significantly lower, at least up to physiological values (P50st = 24.6 [0.6] and 26.2 [0.7]) mmHg; DPG = 14([1.8] and 12.8 [1.2] mumol gHb-1, respectively, in fresh blood). For concentrations above 20 to 25 mumol gHb-1 of DPG the difference between the values of P50st in the two species tended to decrease because the response in human blood reached a plateau. The interactions between the Bohr effect and the concentration of DPG showed that in the horses, as in the men, the level of DPG played an important role in governing the relative magnitude of carbon dioxide and fixed acid factors. The difference between them, which is associated with the oxylabile carbamino binding, was greatest in DPG-depleted blood, but whereas in the men the difference was suppressed by an above normal DPG concentration, in the horses it was still measurable.

  16. Noninvasive determination of myocardial blood flow, oxygen consumption and efficiency in normal humans by carbon-11 acetate positron emission tomography imaging

    International Nuclear Information System (INIS)

    Porenta, G.; Cherry, S.; Czernin, J.; Brunken, R.; Kuhle, W.; Hashimoto, T.; Schelbert, H.R.

    1999-01-01

    The aims of this study were: (1) to measure noninvasively and near simultaneously myocardial blood flow, oxygen consumption, and contractile function and (2) to analyze myocardial energy expenditure and efficiency at rest and during dobutamine stress in normal humans. Dynamic and gated carbon-11 acetate positron emission tomography (PET) imaging was performed in 11 normal subjects. The initial uptake of 11 C-acetate was measured to estimate myocardial blood flow. Oxygen consumption was derived from the monoexponential slope of the 11 C-clearance curve recorded during myocardial washout. ECG-gated systolic and diastolic images were acquired during the peak myocardial 11 C activity to measure left ventricular radius, myocardial wall thickness, and long axis length. Myocardial oxygen consumption and parameters of cardiac geometry were used to determine myocardial energetics and cardiac efficiency by tension-area area analysis. Myocardial blood flow averaged 0.8±0.06 ml min -1 g -1 at rest and 1.48±0.15 ml min -1 g -1 during dobutamine stress. Oxygen delivery and consumption were 151±13 and 88±15 μl O 2 min -1 g -1 at rest and increased to 291±31 and 216±31 μl O 2 min -1 g -1 , respectively, during pharmacological stress (P 11 C acetate imaging provides the unique capability to study noninvasively determinants of myocardial energy delivery, expenditure, and efficiency. (orig.)

  17. Differentiation of Staphylococcus aureus from freshly slaughtered poultry and strains 'endemic' to processing plants by biochemical and physiological tests.

    Science.gov (United States)

    Mead, G C; Norris, A P; Bratchell, N

    1989-02-01

    A comparison was made of 27 'endemic' strains of Staphylococcus aureus and 35 strains from freshly slaughtered birds, isolated at five commercial slaughterhouses processing chickens or turkeys. Of 112 biochemical and physiological tests used, 74 gave results which differed among the strains. Cluster analysis revealed several distinct groupings which were influenced by strain type, processing plant and bird origin; these included a single group at the 72% level of similarity containing most of the 'endemic' strains. In comparison with strains from freshly slaughtered birds, a higher proportion of 'endemic' strains produced fibrinolysin, alpha-glucosidase and urease and were beta-haemolytic on sheep-blood agar. The 'endemic' type also showed a greater tendency to coagulate human but not bovine plasma, and to produce mucoid growth and clumping. The last two properties, relevant to colonization of processing equipment, were less evident in heart infusion broth than in richer media or process water collected during defeathering of the birds.

  18. Fresh market to supermarket: nutrition transition insights from Chiang Mai, Thailand.

    Science.gov (United States)

    Isaacs, Bronwyn Alison; Dixon, Jane; Banwell, Cathy

    2010-06-01

    A preliminary investigation into different eating patterns among Thai consumers who shop at fresh markets as opposed to supermarkets in Chiang Mai. A short questionnaire adopted from a previous study was administered to the forty-four participants, who comprised supermarket users, fresh market users and people who consistently shopped at both supermarkets and fresh markets. Participants were recruited within four fresh markets and two food courts attached to supermarkets in Chiang Mai. Chiang Mai residents who agreed to participate in the study. Equal numbers were regular fresh market and supermarket users. Initial results suggest an association between shopping at supermarkets and attributing bread with culinary value. Supermarkets may be potentially significant players in the 'nutrition transition', providing Thais more convenient shopping at some cost to their healthy food choices.

  19. Novel automated blood separations validate whole cell biomarkers.

    Directory of Open Access Journals (Sweden)

    Douglas E Burger

    Full Text Available Progress in clinical trials in infectious disease, autoimmunity, and cancer is stymied by a dearth of successful whole cell biomarkers for peripheral blood lymphocytes (PBLs. Successful biomarkers could help to track drug effects at early time points in clinical trials to prevent costly trial failures late in development. One major obstacle is the inaccuracy of Ficoll density centrifugation, the decades-old method of separating PBLs from the abundant red blood cells (RBCs of fresh blood samples.To replace the Ficoll method, we developed and studied a novel blood-based magnetic separation method. The magnetic method strikingly surpassed Ficoll in viability, purity and yield of PBLs. To reduce labor, we developed an automated platform and compared two magnet configurations for cell separations. These more accurate and labor-saving magnet configurations allowed the lymphocytes to be tested in bioassays for rare antigen-specific T cells. The automated method succeeded at identifying 79% of patients with the rare PBLs of interest as compared with Ficoll's uniform failure. We validated improved upfront blood processing and show accurate detection of rare antigen-specific lymphocytes.Improving, automating and standardizing lymphocyte detections from whole blood may facilitate development of new cell-based biomarkers for human diseases. Improved upfront blood processes may lead to broad improvements in monitoring early trial outcome measurements in human clinical trials.

  20. Novel automated blood separations validate whole cell biomarkers.

    Science.gov (United States)

    Burger, Douglas E; Wang, Limei; Ban, Liqin; Okubo, Yoshiaki; Kühtreiber, Willem M; Leichliter, Ashley K; Faustman, Denise L

    2011-01-01

    Progress in clinical trials in infectious disease, autoimmunity, and cancer is stymied by a dearth of successful whole cell biomarkers for peripheral blood lymphocytes (PBLs). Successful biomarkers could help to track drug effects at early time points in clinical trials to prevent costly trial failures late in development. One major obstacle is the inaccuracy of Ficoll density centrifugation, the decades-old method of separating PBLs from the abundant red blood cells (RBCs) of fresh blood samples. To replace the Ficoll method, we developed and studied a novel blood-based magnetic separation method. The magnetic method strikingly surpassed Ficoll in viability, purity and yield of PBLs. To reduce labor, we developed an automated platform and compared two magnet configurations for cell separations. These more accurate and labor-saving magnet configurations allowed the lymphocytes to be tested in bioassays for rare antigen-specific T cells. The automated method succeeded at identifying 79% of patients with the rare PBLs of interest as compared with Ficoll's uniform failure. We validated improved upfront blood processing and show accurate detection of rare antigen-specific lymphocytes. Improving, automating and standardizing lymphocyte detections from whole blood may facilitate development of new cell-based biomarkers for human diseases. Improved upfront blood processes may lead to broad improvements in monitoring early trial outcome measurements in human clinical trials.

  1. Using a Combination of Spectral and Textural Data to Measure Water-Holding Capacity in Fresh Chicken Breast Fillets

    Directory of Open Access Journals (Sweden)

    Beibei Jia

    2018-02-01

    Full Text Available The aim here was to explore the potential of visible and near-infrared (Vis/NIR hyperspectral imaging (400–1000 nm to classify fresh chicken breast fillets into different water-holding capacity (WHC groups. Initially, the extracted spectra and image textural features, as well as the mixed data of the two, were used to develop partial least square-discriminant analysis (PLS-DA classification models. Smoothing, a first derivative process, and principle component analysis (PCA were carried out sequentially on the mean spectra of all samples to deal with baseline offsets and identify outlier data. Six samples located outside the confidence ellipses of 95% confidence level in the score plot were defined as outliers. A PLS-DA model based on the outlier-free spectra provided a correct classification rate (CCR value of 78% in the prediction set. Then, seven optimal wavelengths selected using a successive projections algorithm (SPA were used to develop a simplified PLS-DA model that obtained a slightly reduced CCR with a value of 73%. Moreover, the gray-level co-occurrence matrix (GLCM was implemented on the first principle component image (with 98.13% of variance of the hyperspectral image to extract textural features (contrast, correlation, energy, and homogeneity. The CCR of the model developed using textural variables was less optimistic with a value of 59%. Compared to results of models based on spectral or textural data individually, the performance of the model based on the mixed data of optimal spectral and textural features was the best with an improved CCR of 86%. The results showed that the spectral and textural data of hyperspectral images together can be integrated in order to measure and classify the WHC of fresh chicken breast fillets.

  2. Comparison of algorithms for blood stain detection applied to forensic hyperspectral imagery

    Science.gov (United States)

    Yang, Jie; Messinger, David W.; Mathew, Jobin J.; Dube, Roger R.

    2016-05-01

    Blood stains are among the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Early detection of blood stains is particularly important since the blood reacts physically and chemically with air and materials over time. Accurate identification of blood remnants, including regions that might have been intentionally cleaned, is an important aspect of forensic investigation. Hyperspectral imaging might be a potential method to detect blood stains because it is non-contact and provides substantial spectral information that can be used to identify regions in a scene with trace amounts of blood. The potential complexity of scenes in which such vast violence occurs can be high when the range of scene material types and conditions containing blood stains at a crime scene are considered. Some stains are hard to detect by the unaided eye, especially if a conscious effort to clean the scene has occurred (we refer to these as "latent" blood stains). In this paper we present the initial results of a study of the use of hyperspectral imaging algorithms for blood detection in complex scenes. We describe a hyperspectral imaging system which generates images covering 400 nm - 700 nm visible range with a spectral resolution of 10 nm. Three image sets of 31 wavelength bands were generated using this camera for a simulated indoor crime scene in which blood stains were placed on a T-shirt and walls. To detect blood stains in the scene, Principal Component Analysis (PCA), Subspace Reed Xiaoli Detection (SRXD), and Topological Anomaly Detection (TAD) algorithms were used. Comparison of the three hyperspectral image analysis techniques shows that TAD is most suitable for detecting blood stains and discovering latent blood stains.

  3. Characterization and Application of Autochthonous Starter Cultures for Fresh Cheese Production

    Directory of Open Access Journals (Sweden)

    Andreja Leboš Pavunc

    2012-01-01

    Full Text Available The use of commercial starter cultures in fresh cheese production from pasteurized milk results in the loss of typical characteristics of artisan fresh cheese due to the replacement of complex native microbiota with a defined starter culture. Hence, the aim of this research is to isolate and characterize dominant lactic acid bacteria (LAB in artisan fresh cheese and to evaluate their capacity as autochthonous starter cultures for fresh cheese production. Fifteen most prevalent Gram-positive, catalase-negative and asporogenous bacterial strains were selected for a more detailed characterization. Eleven lactic acid bacterial strains were determined to be homofermentative cocci and four heterofermentative lactobacilli. Further phenotypic and genotypic analyses revealed that those were two different LAB strains with high acidifying and proteolytic activity, identified as Lactobacillus fermentum A8 and Enterococcus faecium A7. These two autochthonous strains, alone or in combination with commercial starter, were used to produce different types of fresh cheese, which were evaluated by a panel. Conventional culturing, isolation, identification and PCR-denaturing gradient gel electrophoresis (PCR-DGGE procedures, applied to the total fresh cheese DNA extracts, were employed to define and monitor the viability of the introduced LAB strains and their effect on the final product characteristics. Production of fresh cheese using a combination of commercial starter culture and selected autochthonous strains resulted in improved sensorial properties, which were more similar to the ones of spontaneously fermented fresh cheese than to those of cheese produced with only starter culture or selected strains. After 10 days of storage, that cheese retained the best sensorial properties in comparison with all other types of cheese. The presence of inoculated autochthonous and starter cultures and their identification was demonstrated by DGGE analysis. The obtained

  4. Blood Vessel Extraction in Color Retinal Fundus Images with Enhancement Filtering and Unsupervised Classification

    Directory of Open Access Journals (Sweden)

    Zafer Yavuz

    2017-01-01

    Full Text Available Retinal blood vessels have a significant role in the diagnosis and treatment of various retinal diseases such as diabetic retinopathy, glaucoma, arteriosclerosis, and hypertension. For this reason, retinal vasculature extraction is important in order to help specialists for the diagnosis and treatment of systematic diseases. In this paper, a novel approach is developed to extract retinal blood vessel network. Our method comprises four stages: (1 preprocessing stage in order to prepare dataset for segmentation; (2 an enhancement procedure including Gabor, Frangi, and Gauss filters obtained separately before a top-hat transform; (3 a hard and soft clustering stage which includes K-means and Fuzzy C-means (FCM in order to get binary vessel map; and (4 a postprocessing step which removes falsely segmented isolated regions. The method is tested on color retinal images obtained from STARE and DRIVE databases which are available online. As a result, Gabor filter followed by K-means clustering method achieves 95.94% and 95.71% of accuracy for STARE and DRIVE databases, respectively, which are acceptable for diagnosis systems.

  5. Estimating Pasture Quality of Fresh Vegetation Based on Spectral Slope of Mixed Data of Dry and Fresh Vegetation—Method Development

    Directory of Open Access Journals (Sweden)

    Rachel Lugassi

    2015-06-01

    Full Text Available The main objective of the present study was to apply a slope-based spectral method to both dry and fresh pasture vegetation. Differences in eight spectral ranges were identified across the near infrared-shortwave infrared (NIR-SWIR that were indicative of changes in chemical properties. Slopes across these ranges were calculated and a partial least squares (PLS analytical model was constructed for the slopes vs. crude protein (CP and neutral detergent fiber (NDF contents. Different datasets with different numbers of fresh/dry samples were constructed to predict CP and NDF contents. When using a mixed-sample dataset with dry-to-fresh ratios of 85%:15% and 75%:25%, the correlations of CP (R2 = 0.95, in both and NDF (R2 = 0.84 and 0.82, respectively were almost as high as when using only dry samples (0.97 and 0.85, respectively. Furthermore, satisfactory correlations were obtained with a dry-to-fresh ratio of 50%:50% for CP (R2 = 0.92. The results of our study are especially encouraging because CP and NDF contents could be predicted even though some of the selected spectral regions were directly affected by atmospheric water vapor or water in the plants.

  6. Toward an Improved Understanding of the Global Fresh Water Budget

    Science.gov (United States)

    Hildebrand, Peter H.

    2005-01-01

    The major components of the global fresh water cycle include the evaporation from the land and ocean surfaces, precipitation onto the Ocean and land surfaces, the net atmospheric transport of water from oceanic areas over land, and the return flow of water from the land back into the ocean. The additional components of oceanic water transport are few, principally, the mixing of fresh water through the oceanic boundary layer, transport by ocean currents, and sea ice processes. On land the situation is considerably more complex, and includes the deposition of rain and snow on land; water flow in runoff; infiltration of water into the soil and groundwater; storage of water in soil, lakes and streams, and groundwater; polar and glacial ice; and use of water in vegetation and human activities. Knowledge of the key terms in the fresh water flux budget is poor. Some components of the budget, e.g. precipitation, runoff, storage, are measured with variable accuracy across the globe. We are just now obtaining precise measurements of the major components of global fresh water storage in global ice and ground water. The easily accessible fresh water sources in rivers, lakes and snow runoff are only adequately measured in the more affluent portions of the world. presents proposals are suggesting methods of making global measurements of these quantities from space. At the same time, knowledge of the global fresh water resources under the effects of climate change is of increasing importance and the human population grows. This paper provides an overview of the state of knowledge of the global fresh water budget, evaluating the accuracy of various global water budget measuring and modeling techniques. We review the measurement capabilities of satellite instruments as compared with field validation studies and modeling approaches. Based on these analyses, and on the goal of improved knowledge of the global fresh water budget under the effects of climate change, we suggest

  7. Legal and ethical issues in safe blood transfusion

    Directory of Open Access Journals (Sweden)

    Shivaram Chandrashekar

    2014-01-01

    Full Text Available Legal issues play a vital role in providing a framework for the Indian blood transfusion service (BTS, while ethical issues pave the way for quality. Despite licensing of all blood banks, failure to revamp the Drugs and Cosmetic Act (D and C Act is impeding quality. Newer techniques like chemiluminescence or nucleic acid testing (NAT find no mention in the D and C Act. Specialised products like pooled platelet concentrates or modified whole blood, therapeutic procedures like erythropheresis, plasma exchange, stem cell collection and processing technologies like leukoreduction and irradiation are not a part of the D and C Act. A highly fragmented BTS comprising of over 2500 blood banks, coupled with a slow and tedious process of dual licensing (state and centre is a hindrance to smooth functioning of blood banks. Small size of blood banks compromises blood safety. New blood banks are opened in India by hospitals to meet requirements of insurance providers or by medical colleges as this a Medical Council of India (MCI requirement. Hospital based blood banks opt for replacement donation as they are barred by law from holding camps. Demand for fresh blood, lack of components, and lack of guidelines for safe transfusion leads to continued abuse of blood. Differential pricing of blood components is difficult to explain scientifically or ethically. Accreditation of blood banks along with establishment of regional testing centres could pave the way to blood safety. National Aids Control Organisation (NACO and National Blood Transfusion Council (NBTC deserve a more proactive role in the licensing process. The Food and Drug Administration (FDA needs to clarify that procedures or tests meant for enhancement of blood safety are not illegal.

  8. R and G color component competition of RGB image decomposition as a criterion to register RBC agglutinates for blood group typing.

    Science.gov (United States)

    Doubrovski, Valeri A; Ganilova, Yuliya A; Zabenkov, Igor V

    2014-03-01

    A new approach of the criterion assignment for registration of erythrocyte agglutinates to instrumentally determine blood group type is suggested. The criterion is based on comparison of R and G components of RGB decomposition of microscopy digital image taken for the blood-serum mixture sample. For the chosen experimental conditions, the minimal size (area) of RBC agglutinate to be registered by the criterion suggested is estimated theoretically. The proposed method was tested experimentally on the example of monitoring agglutinates in flow. The encouraging experimental results were obtained for improvement of the resolving power of the method; the optimal experimental conditions were revealed for maximum resolution. Though the suggested method was realized for dynamic (flow) blood group determination, it could also be applied for diagnostics in a stationary environment. This approach increases the reliability of RBC agglutinates registration and, hence, blood group typing. The results may be used to develop the apparatus for automated determination of human blood group.

  9. Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT.

    Science.gov (United States)

    Komar, Gaber; Oikonen, Vesa; Sipilä, Hannu; Seppänen, Marko; Minn, Heikki

    2012-11-01

    The aim of this study was to develop a simple noninvasive method for measuring blood flow using [15O]H2O PET/CT for the head and neck area applicable in daily clinical practice. Fifteen dynamic [15O]H2O PET emission scans with simultaneous online radioactivity measurements of radial arterial blood [Blood-input functions (IFs)] were performed. Two noninvasively obtained population-based input functions were calculated by averaging all Blood-IF curves corrected for patients' body mass and injected dose [standardized uptake value (SUV)-IF] and for body surface area (BSA-IF) and injected dose. Parametric perfusion images were calculated for each set of IFs using a linearized two-compartment model, and values for several tissues were compared using Blood-IF as the gold standard. On comparing all tissues, the correlation between blood flow obtained with the invasive Blood-IF and both SUV-IF and BSA-IF was significant (R2=0.785 with P<0.001 and R2=0.813 with P<0.001, respectively). In individual tissues, the performance of the two noninvasive methods was most reliable in resting muscle and slightly less reliable in tumour and cerebellar regions. In these two tissues, only BSA-IF showed a significant correlation with Blood-IF (R2=0.307 with P=0.032 in tumours and R2=0.398 with P<0.007 in the cerebellum). The BSA-based noninvasive method enables clinically relevant delineation between areas of low and high blood flow in tumours. The blood flow of low-perfusion tissues can be reliably quantified using either of the evaluated noninvasive methods.

  10. Apparent brain temperature imaging with multi-voxel proton magnetic resonance spectroscopy compared with cerebral blood flow and metabolism imaging on positron emission tomography in patients with unilateral chronic major cerebral artery steno-occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Nanba, Takamasa; Nishimoto, Hideaki; Murakami, Toshiyuki; Fujiwara, Shunrou; Ogasawara, Kuniaki [Iwate Medical University, Department of Neurosurgery, Iwate (Japan); Yoshioka, Yoshichika [Osaka University, Open and Transdisciplinary Research Initiatives, Osaka (Japan); Sasaki, Makoto; Uwano, Ikuko [Iwate Medical University, Institute for Biomedical Science, Iwate (Japan); Terasaki, Kazunori [Iwate Medical University, Cyclotron Research Center, Iwate (Japan)

    2017-09-15

    The purpose of the present study was to determine whether apparent brain temperature imaging using multi-voxel proton magnetic resonance (MR) spectroscopy correlates with cerebral blood flow (CBF) and metabolism imaging in the deep white matter of patients with unilateral chronic major cerebral artery steno-occlusive disease. Apparent brain temperature and CBF and metabolism imaging were measured using proton MR spectroscopy and {sup 15}O-positron emission tomography (PET), respectively, in 35 patients. A set of regions of interest (ROIs) of 5 x 5 voxels was placed on an MR image so that the voxel row at each edge was located in the deep white matter of the centrum semiovale in each cerebral hemisphere. PET images were co-registered with MR images with these ROIs and were re-sliced automatically using image analysis software. In 175 voxel pairs located in the deep white matter, the brain temperature difference (affected hemisphere - contralateral hemisphere: ΔBT) was correlated with cerebral blood volume (CBV) (r = 0.570) and oxygen extraction fraction (OEF) ratios (affected hemisphere/contralateral hemisphere) (r = 0.641). We excluded voxels that contained ischemic lesions or cerebrospinal fluid and calculated the mean values of voxel pairs in each patient. The mean ΔBT was correlated with the mean CBF (r = - 0.376), mean CBV (r = 0.702), and mean OEF ratio (r = 0.774). Apparent brain temperature imaging using multi-voxel proton MR spectroscopy was correlated with CBF and metabolism imaging in the deep white matter of patients with unilateral major cerebral artery steno-occlusive disease. (orig.)

  11. A preliminary study of placental umbilical cord whole blood transfusion in under resourced patients with malaria in the background of anaemia.

    Science.gov (United States)

    Bhattacharya, Niranjan

    2006-03-23

    Malaria is an annual killer of over one million people globally and its essential co-morbidity is anaemia. Cord blood, because of its rich mix of foetal and adult haemoglobin, high platelet and WBC counts, hypo-antigenic nature, altered metabolic profile and high affinity for oxygen as well as its anti-malarial effect, is an ideal choice in malaria with anaemia, necessitating blood transfusion. This paper presents an alternative protocol for fresh whole blood/packed cell transfusion from the hospital's biological waste resources, i.e., the placenta, after the birth of a healthy baby from a healthy mother. This collected blood was routinely transfused to patients admitted in our hospital with severe anaemia in the background of confirmed malaria. 94 units of placental umbilical cord whole blood were collected after lower uterine caesarean section (LUCS) from consenting mothers (from 1st April 1999 to April 2005), and safely transfused to 39 informed, consenting patients (age varying from 8 to 72 years). The collected volume of cord blood from each placenta (Unit) varied from 52 ml to 143 ml, with a mean packed cell volume of 48.9 +/- 4.1 SD and a mean haemoglobin concentration of 16.4 Gm percent +/- 1.6 Gm percent SD. The blood was immediately transfused after following the standard adult blood transfusion protocol of screening and cross-matching between the donor and the recipient. On occasion, the collected cord blood was preserved in the refrigerator, if no volunteer was readily available, and transfused within 72 hours of collection. Cord blood transfusion was tested on twenty two patients infected with Plasmodium falciparum and 17 patients with Plasmodium vivax. For inclusion in this study, the patient's plasma haemoglobin had to be 8 gm percent or less (the pre-transfusion haemoglobin in the malaria-infected patients in this series varied from 5.4 gm/dl to 7.9 gm/dl). The rise of haemoglobin within 72 hours of two units of freshly collected cord blood

  12. A preliminary study of placental umbilical cord whole blood transfusion in under resourced patients with malaria in the background of anaemia

    Directory of Open Access Journals (Sweden)

    Bhattacharya Niranjan

    2006-03-01

    Full Text Available Abstract Background Malaria is an annual killer of over one million people globally and its essential co-morbidity is anaemia. Cord blood, because of its rich mix of foetal and adult haemoglobin, high platelet and WBC counts, hypo-antigenic nature, altered metabolic profile and high affinity for oxygen as well as its anti-malarial effect, is an ideal choice in malaria with anaemia, necessitating blood transfusion. Methods This paper presents an alternative protocol for fresh whole blood/packed cell transfusion from the hospital's biological waste resources, i.e., the placenta, after the birth of a healthy baby from a healthy mother. This collected blood was routinely transfused to patients admitted in our hospital with severe anaemia in the background of confirmed malaria. 94 units of placental umbilical cord whole blood were collected after lower uterine caesarean section (LUCS from consenting mothers (from 1st April 1999 to April 2005, and safely transfused to 39 informed, consenting patients (age varying from 8 to 72 years. The collected volume of cord blood from each placenta (Unit varied from 52 ml to 143 ml, with a mean packed cell volume of 48.9 ± 4.1 SD and a mean haemoglobin concentration of 16.4 Gm percent ± 1.6 Gm percent SD. The blood was immediately transfused after following the standard adult blood transfusion protocol of screening and cross-matching between the donor and the recipient. On occasion, the collected cord blood was preserved in the refrigerator, if no volunteer was readily available, and transfused within 72 hours of collection. Results Cord blood transfusion was tested on twenty two patients infected with Plasmodium falciparum and 17 patients with Plasmodium vivax. For inclusion in this study, the patient's plasma haemoglobin had to be 8 gm percent or less (the pre-transfusion haemoglobin in the malaria-infected patients in this series varied from 5.4 gm/dl to 7.9 gm/dl. The rise of haemoglobin within 72 hours of

  13. A Neural-Network-Based Approach to White Blood Cell Classification

    Directory of Open Access Journals (Sweden)

    Mu-Chun Su

    2014-01-01

    Full Text Available This paper presents a new white blood cell classification system for the recognition of five types of white blood cells. We propose a new segmentation algorithm for the segmentation of white blood cells from smear images. The core idea of the proposed segmentation algorithm is to find a discriminating region of white blood cells on the HSI color space. Pixels with color lying in the discriminating region described by an ellipsoidal region will be regarded as the nucleus and granule of cytoplasm of a white blood cell. Then, through a further morphological process, we can segment a white blood cell from a smear image. Three kinds of features (i.e., geometrical features, color features, and LDP-based texture features are extracted from the segmented cell. These features are fed into three different kinds of neural networks to recognize the types of the white blood cells. To test the effectiveness of the proposed white blood cell classification system, a total of 450 white blood cells images were used. The highest overall correct recognition rate could reach 99.11% correct. Simulation results showed that the proposed white blood cell classification system was very competitive to some existing systems.

  14. Depiction of blood vessels by x-ray phase contrast

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [School of Engineering, University of Tokyo, Tokyo (Japan); Takeda, Tohoru; Itai, Yuji [Institute of Clinical Medicine, University of Tsukuba, Tsukuba, Ibaraki (Japan)

    2001-04-01

    Blood vessels in livers of a mouse and a rat were depicted by phase-contrast x-ray imaging with an x-ray interferometer without using contrast agents. X-ray interference patterns were converted to image mapping x-ray phase shift caused by the livers using the technique of phase-shifting x-ray interferometry. The arteries and veins to and from the livers were tied before excision in order to prevent blood from flowing out of the liver. The x-ray phase shift caused by blood was substantially different from that caused by other soft sues, and consequently trees of blood vessels were revealed in the images. Vessels of diameter smaller than 0.1 mm were detected. This result suggests new possibilities for investigating vascular systems. (author)

  15. The impact of hydration changes in fresh bio-tissue on THz spectroscopic measurements

    International Nuclear Information System (INIS)

    Png, G M; Ng, B W-H; Mickan, S P; Abbott, D; Choi, J W; Zhang, X-C

    2008-01-01

    We present a study of how residual hydration in fresh rat tissue samples can vastly alter their extracted terahertz (THz) optical properties and influence their health assessment. Fresh (as opposed to preserved) tissue most closely mimics in vivo conditions, but high water content creates many challenges for tissue handling and THz measurement. Our THz measurements of fresh tissue over time highlight the effect of tissue hydration on tissue texture and dimension, the latter directly influencing the accuracy of calculated optical properties. We then introduce lyophilization (freeze drying) as a viable solution for overcoming hydration and freshness problems. Lyophilization removes large amounts of water while retaining sample freshness. In addition, lyophilized tissue samples are easy to handle and their textures and dimensions do not vary over time, allowing for consistent and stable THz measurements. A comparison of lyophilized and fresh tissue shows for the first time that freeze drying may be one way of overcoming tissue hydration issues while preserving tissue cellular structure. Finally, we compare THz measurements from fresh tissue against necrotic tissue to verify freshness over time. Indeed, THz measurements from fresh and necrotic tissues show marked differences

  16. Study of 99Tcm-annexin V distribution in inferior vena cava thrombus models of rabbits

    International Nuclear Information System (INIS)

    Wu Dayong; Zhang Wenyan; Bian Yanzhu; Hu Yujing

    2013-01-01

    To study 99 Tc m -Annexin V distribution in inferior vena cava thrombus models of rabbits and uptake of 99 Tc m -Annexin V in fresh and old venous thrombus. Rabbits (n=15) were randomly grouped into 3 groups (the fresh thrombus group, old thrombus group, and control group). The rabbits of two thrombus groups developed inferior vena cava thrombus models by operations. The control group received sham operation. The fresh thrombus group and control group rabbits were injected 99 Tc m -Annexin V after operating 1 d; the old thrombus group 14 d. After 1 h all rabbits were killed by injecting overdose pentobarbital sodium. The thrombus (or the inferior vena cava about 3 cm below inferior pole of right kidney level in the control group rabbits), blood, thrombus area inferior vena cava, head lateral inferior vena cava (except the control group), thigh muscle, stomach, myocardium, pulmonary, liver, kidney, spleen, bone and small intestine were obtained from all group rabbits. The ex tissue and blood were weighed and measured by a Well-type detector. The percentage of the injected dose per gram of ex tissue (or blood) was calculated by the above data. The thrombus to blood, thrombus area inferior vena cava, head lateral inferior vena cava and thigh muscle ratios were calculated by percentage of the injected dose per gram of ex tissue (or blood). The test was used to compare the fresh thrombus group and old thrombus group by SPSS 17.0. The percentage of' the injected dose per gram of thrombi (0.01894± 0.002 16% ID/g) in the fresh thrombus group was higher than the old thrombus group (0.00473±0.001 28% ID/g), P<0.05. The thrombus to blood, thrombus area inferior vena cava, head lateral inferior vena cava and muscle ratios (3.42±1.06, 26.32±13.60, 31.23 ±16.00, 111.62±52.23) in the fresh thrombus group were higher than the old thrombus group (0.98±0.09, 5.12±2.01, 6.25±2.38, 21.82±5.93), P<0.05 for all. All the thrombi of the fresh thrombus group were confirmed

  17. Spoilage and shelf-life extension of fresh fish and shellfish.

    Science.gov (United States)

    Ashie, I N; Smith, J P; Simpson, B K

    1996-01-01

    Fresh fish and shellfish are highly perishable products due to their biological composition. Under normal refrigerated storage conditions, the shelf life of these products is limited by enzymatic and microbiological spoilage. However, with increasing consumer demands for fresh products with extended shelf life and increasing energy costs associated with freezing and frozen storage, the fish-processing industry is actively seeking alternative methods of shelf life preservation and marketability of fresh, refrigerated fish and at the same time economizing on energy costs. Additional methods that could fulfill these objectives include chemical decontamination, low-dose irradiation, ultra-high pressure, and modified atmosphere packaging (MAP). This review focuses on the biochemical and microbiological composition of fresh fish/shellfish, the spoilage patterns in these products, factors influencing spoilage, and the combination treatments that can be used in conjunction with refrigeration to extend the shelf life and keeping quality of fresh fish/shellfish. The safety concerns of minimally processed/MAP fish, specifically with respect to the growth of Clostridium botulinum type E, is also addressed.

  18. Option contracts in fresh produce supply chain with circulation loss

    Directory of Open Access Journals (Sweden)

    Chong Wang

    2013-03-01

    Full Text Available Purpose: The purpose of this paper is to investigate management decisions via option contracts in a two-stage supply chain in which a fresh produce supplier sells to a retailer, considering the circulation loss of the fresh produce. Design/methodology/approach: Authors propose a Stackelberg model to analyze the supply chain members’ decisions in the decentralized supply chain compared with the integrated one under the newsvendor framework. Findings: The results illustrate that there exists a unique optimal option order quantity for the retailer and a unique optimal option order price for the supplier giving certain conditions; furthermore, option contracts cannot coordinate the fresh produce supply chain when the retailer only orders options. Originality/value: Agricultural products especially fresh produce’s characteristics such as circulation loss and high risk are considered. Option contracts and game theory are combined to manage the fresh produce supply chain’s risk. The proposed tool and models are hoped to shed light to the future works in the field of supply chain risk management.

  19. [Internal quality control of the blood products in the Lomé National Blood Transfusion Centre].

    Science.gov (United States)

    Fétéké, L; Mawussi, K; Lakté, P; Kuéviakoe, I M; Haudrechy, D; Ségbéna, A Y

    2008-07-01

    Evaluate the conformity of blood red cells units prepared in the Lomé CNTS with European norms concerning volume, haemoglobin content and haematocrite. Measure the conservation of the haemostatic properties and the rate of haemostasis factors V and VIII in the fresh frozen plasma. Measure the rate of residual cells in the plasma. In the year 2006, from March 1st to April 15th, we analysed the quality of 135 units of whole blood, red blood cells (RBC) and plasma from blood donors in the Lomé National Blood Transfusion Centre. The quality control had concerned: the volume of whole blood units; the volume, the haemoglobin content and the haematocrite of red blood cells units; the volume, the prothrombin rate, the cephalin with activator time (TCA), the rate of haemostasis factors V and VIII and the number of residual cells (red cells, leucocytes and platelets) in the plasma. Among the 135 units of whole blood which were controlled, 50.57% were in conformity with the norms concerning the volume. The red blood cells units were in conformity with norms concerning their volume, their haemoglobin content and their haematocrite respectively in 21.48%, 80.75% and 20% of the cases. The volume of 75.56% of the plasma units controlled were conform with the norm. All of the plasma units were conform with the norm concerning the number of residual platelets while the number of residual red blood cells and leucocytes were conform respectively in 80.74% and 60%. The percentage of conformity concerning the prothrombin rate, the TCA, the coagulation factor V and the factor VIII were respectively 66.67; 97.78; 48.89 and 47.4 before freezing, and 54.81; 88.14; 64.44; 84.44 a month after freezing. To improve the quality of the new blood products of the Lomé CNTS, some correctives actions must be applied concerning the adequate volume of blood which must be collected from the donors, the position of the blood bags in during the centrifugation and the volume of plasma which must be

  20. Rumen dry matter degradability of fresh and ensiled sugarcane ...

    African Journals Online (AJOL)

    This study aimed to evaluate the chemical composition and in situ ruminal degradability of fresh (FSC) and ensiled (ESC) sugarcane. In situ dry matter degradability (DMD) was determined using the nylon bag technique with four cows equipped ruminal fistulas. Cows were fed with fresh or ensiled sugarcane and ...