WorldWideScience

Sample records for frequency scanning interferometery

  1. LOFAR for lightning-interferometery and mapping

    NARCIS (Netherlands)

    Scholten, Olaf; Buitink, Stijn; trinh, Gia; Bonardi, Antonio; Corstanje, Arthur; Ebert, Ute; Falcke, Heino; Hoerandel, Joerg; Mitra, Pragati; Mulrey, Katherine; Nelles, Anna; Rachen, Joerg; Rossetto, Laura; Rutjes, Casper; Schellart, Pim; Thoudam, Satayendra; ter Veen, Sander; Winchen, Tobias; Hare, Brian

    2017-01-01

    We show that a new observation mode at the Low Frequency Array (LOFAR) for Lightning-Interferometery and Mapping (LIM) allows for lightning observations with a resolution that is at least an order of magnitude better than presently operating Lightning Napping Arrays LMAs. Furthermore the

  2. An investigation of frequency scanning interferometery for the alignment of the ATLAS semiconductor tracker

    CERN Document Server

    Coe, P A

    2001-01-01

    The relative alignment of the silicon detector modules of the ATLAS semiconductor tracker will need remote monitoring during operation, within a high radiation environment. A geodetic grid of distance measurement fibre-coupled interferometers will monitor changes in the shape of the support structure. Eight hundred fibre-coupled grid line interferometers (GLIs) will be compared simultaneously to a stable, evacuated reference interferometer using Frequency Scanning Interferometry (FSI). The GLIs, (from 70 mm to 1400mm long, with pW level return signals) must be measured to a precision of 1 micron, to reconstruct the grid shape, in three dimensions, to a precision of 10 microns. In this work two important limitations were overcome: 1. Inflated errors due to relative interferometer drift were significantly reduced using two lasers scanned in opposite directions. 2. The fine tuning range was effectively extended by linking the phase information in two 30 GHz fine tuning subscans, separated by a 3.5 THz coarse tun...

  3. Frequency scanning microstrip antennas

    DEFF Research Database (Denmark)

    Danielsen, Magnus; Jørgensen, Rolf

    1979-01-01

    The principles of using radiating microstrip resonators as elements in a frequency scanning antenna array are described. The resonators are cascade-coupled. This gives a scan of the main lobe due to the phase-shift in the resonator in addition to that created by the transmission line phase......-shift. Experimental results inX-band, in good agreement with the theory, show that it is possible to scan the main lobe an angle ofpm30degby a variation of the frequencypm300MHz, and where the 3 dB beamwidth is less than10deg. The directivity was 14.7 dB, while the gain was 8.1 dB. The efficiency might be improved...

  4. Input signal shaping based on harmonic frequency response function for suppressing nonlinear optical frequency in frequency-scanning interferometry

    Science.gov (United States)

    Zhu, Yu; Liu, Zhigang; Deng, Wen; Deng, Zhongwen

    2018-05-01

    Frequency-scanning interferometry (FSI) using an external cavity diode laser (ECDL) is essential for many applications of the absolute distance measurement. However, owing to the hysteresis and creep of the piezoelectric actuator inherent in the ECDL, the optical frequency scanning exhibits a nonlinearity that seriously affects the phase extraction accuracy of the interference signal and results in the reduction of the measurement accuracy. To suppress the optical frequency nonlinearity, a harmonic frequency synthesis method for shaping the desired input signal instead of the original triangular wave is presented. The effectiveness of the presented shaping method is demonstrated through the comparison of the experimental results. Compared with an incremental Renishaw interferometer, the standard deviation of the displacement measurement of the FSI system is less than 2.4 μm when driven by the shaped signal.

  5. Frequency scanning-based stability analysis method for grid-connected inverter system

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    This paper proposes a frequency scanning-based impedance analysis for stability assessment of grid-connected inverter system, which is able to perform stability assessment without using system mathematical models and inherit the superior feature of impedance-based stability criterion with conside......This paper proposes a frequency scanning-based impedance analysis for stability assessment of grid-connected inverter system, which is able to perform stability assessment without using system mathematical models and inherit the superior feature of impedance-based stability criterion...... with consideration of the inverter nonlinearities. Small current disturbance is injected into grid-connected inverter system in a particular frequency range, and the impedance is computed according to the harmonic-frequency response using Fourier analysis, and then the stability is predicted on the basis...... of the impedance stability criterion. The stability issues of grid-connected inverters with grid-current feedback and the converter-current feedback are addressed using the proposed method. The results obtained from simulation and experiments validate the effectiveness of the method. The frequency scanning...

  6. Distance measurement using frequency scanning interferometry with mode-hoped laser

    Science.gov (United States)

    Medhat, M.; Sobee, M.; Hussein, H. M.; Terra, O.

    2016-06-01

    In this paper, frequency scanning interferometry is implemented to measure distances up to 5 m absolutely. The setup consists of a Michelson interferometer, an external cavity tunable diode laser, and an ultra-low expansion (ULE) Fabry-Pérot (FP) cavity to measure the frequency scanning range. The distance is measured by acquiring simultaneously the interference fringes from, the Michelson and the FP interferometers, while scanning the laser frequency. An online fringe processing technique is developed to calculate the distance from the fringe ratio while removing the parts result from the laser mode-hops without significantly affecting the measurement accuracy. This fringe processing method enables accurate distance measurements up to 5 m with measurements repeatability ±3.9×10-6 L. An accurate translation stage is used to find the FP cavity free-spectral-range and therefore allow accurate measurement. Finally, the setup is applied for the short distance calibration of a laser distance meter (LDM).

  7. Characteristics of different frequency ranges in scanning electron microscope images

    International Nuclear Information System (INIS)

    Sim, K. S.; Nia, M. E.; Tan, T. L.; Tso, C. P.; Ee, C. S.

    2015-01-01

    We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement

  8. Characteristics of different frequency ranges in scanning electron microscope images

    Energy Technology Data Exchange (ETDEWEB)

    Sim, K. S., E-mail: kssim@mmu.edu.my; Nia, M. E.; Tan, T. L.; Tso, C. P.; Ee, C. S. [Faculty of Engineering and Technology, Multimedia University, 75450 Melaka (Malaysia)

    2015-07-22

    We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.

  9. Combined frequency modulated atomic force microscopy and scanning tunneling microscopy detection for multi-tip scanning probe microscopy applications

    International Nuclear Information System (INIS)

    Morawski, Ireneusz; Spiegelberg, Richard; Korte, Stefan; Voigtländer, Bert

    2015-01-01

    A method which allows scanning tunneling microscopy (STM) tip biasing independent of the sample bias during frequency modulated atomic force microscopy (AFM) operation is presented. The AFM sensor is supplied by an electronic circuit combining both a frequency shift signal and a tunneling current signal by means of an inductive coupling. This solution enables a control of the tip potential independent of the sample potential. Individual tip biasing is specifically important in order to implement multi-tip STM/AFM applications. An extensional quartz sensor (needle sensor) with a conductive tip is applied to record simultaneously topography and conductivity of the sample. The high resonance frequency of the needle sensor (1 MHz) allows scanning of a large area of the surface being investigated in a reasonably short time. A recipe for the amplitude calibration which is based only on the frequency shift signal and does not require the tip being in contact is presented. Additionally, we show spectral measurements of the mechanical vibration noise of the scanning system used in the investigations

  10. Combined frequency modulated atomic force microscopy and scanning tunneling microscopy detection for multi-tip scanning probe microscopy applications

    Energy Technology Data Exchange (ETDEWEB)

    Morawski, Ireneusz [Peter Grünberg Institut (PGI-3) and JARA-Fundamentals of Future Information Technology, Forschungszentrum Jülich, 52425 Jülich (Germany); Institute of Experimental Physics, University of Wrocław, pl. M. Borna 9, 50-204 Wrocław (Poland); Spiegelberg, Richard; Korte, Stefan; Voigtländer, Bert [Peter Grünberg Institut (PGI-3) and JARA-Fundamentals of Future Information Technology, Forschungszentrum Jülich, 52425 Jülich (Germany)

    2015-12-15

    A method which allows scanning tunneling microscopy (STM) tip biasing independent of the sample bias during frequency modulated atomic force microscopy (AFM) operation is presented. The AFM sensor is supplied by an electronic circuit combining both a frequency shift signal and a tunneling current signal by means of an inductive coupling. This solution enables a control of the tip potential independent of the sample potential. Individual tip biasing is specifically important in order to implement multi-tip STM/AFM applications. An extensional quartz sensor (needle sensor) with a conductive tip is applied to record simultaneously topography and conductivity of the sample. The high resonance frequency of the needle sensor (1 MHz) allows scanning of a large area of the surface being investigated in a reasonably short time. A recipe for the amplitude calibration which is based only on the frequency shift signal and does not require the tip being in contact is presented. Additionally, we show spectral measurements of the mechanical vibration noise of the scanning system used in the investigations.

  11. Atomic resolution ultrafast scanning tunneling microscope with scan rate breaking the resonant frequency of a quartz tuning fork resonator.

    Science.gov (United States)

    Li, Quanfeng; Lu, Qingyou

    2011-05-01

    We present an ultra-fast scanning tunneling microscope with atomic resolution at 26 kHz scan rate which surpasses the resonant frequency of the quartz tuning fork resonator used as the fast scan actuator. The main improvements employed in achieving this new record are (1) fully low voltage design (2) independent scan control and data acquisition, where the tuning fork (carrying a tip) is blindly driven to scan by a function generator with the scan voltage and tunneling current (I(T)) being measured as image data (this is unlike the traditional point-by-point move and measure method where data acquisition and scan control are switched many times).

  12. Radio frequency scanning tunneling spectroscopy for single-molecule spin resonance.

    Science.gov (United States)

    Müllegger, Stefan; Tebi, Stefano; Das, Amal K; Schöfberger, Wolfgang; Faschinger, Felix; Koch, Reinhold

    2014-09-26

    We probe nuclear and electron spins in a single molecule even beyond the electromagnetic dipole selection rules, at readily accessible magnetic fields (few mT) and temperatures (5 K) by resonant radio-frequency current from a scanning tunneling microscope. We achieve subnanometer spatial resolution combined with single-spin sensitivity, representing a 10 orders of magnitude improvement compared to existing magnetic resonance techniques. We demonstrate the successful resonant spectroscopy of the complete manifold of nuclear and electronic magnetic transitions of up to ΔI(z)=±3 and ΔJ(z)=±12 of single quantum spins in a single molecule. Our method of resonant radio-frequency scanning tunneling spectroscopy offers, atom-by-atom, unprecedented analytical power and spin control with an impact on diverse fields of nanoscience and nanotechnology.

  13. Microwave Frequency Comb from a Semiconductor in a Scanning Tunneling Microscope.

    Science.gov (United States)

    Hagmann, Mark J; Yarotski, Dmitry A; Mousa, Marwan S

    2017-04-01

    Quasi-periodic excitation of the tunneling junction in a scanning tunneling microscope, by a mode-locked ultrafast laser, superimposes a regular sequence of 15 fs pulses on the DC tunneling current. In the frequency domain, this is a frequency comb with harmonics at integer multiples of the laser pulse repetition frequency. With a gold sample the 200th harmonic at 14.85 GHz has a signal-to-noise ratio of 25 dB, and the power at each harmonic varies inversely with the square of the frequency. Now we report the first measurements with a semiconductor where the laser photon energy must be less than the bandgap energy of the semiconductor; the microwave frequency comb must be measured within 200 μm of the tunneling junction; and the microwave power is 25 dB below that with a metal sample and falls off more rapidly at the higher harmonics. Our results suggest that the measured attenuation of the microwave harmonics is sensitive to the semiconductor spreading resistance within 1 nm of the tunneling junction. This approach may enable sub-nanometer carrier profiling of semiconductors without requiring the diamond nanoprobes in scanning spreading resistance microscopy.

  14. Frequency scanning interferometry for CLIC component fiducialisation

    CERN Document Server

    Kamugasa, Solomon William; Mainaud Durand, Helene; CERN. Geneva. ATS Department

    2016-01-01

    We present a strategy for the fiducialisation of CLIC’s Main Beam Quadrupole (MBQ) magnets using Frequency Scanning Interferometry (FSI). We have developed complementary device for a commercial FSI system to enable coordinate determination via multilateration. Using spherical high index glass retroreflectors with a wide acceptance angle, we optimise the geometry of measurement stations with respect to fiducials -- thus improving the precision of coordinates. We demonstrate through simulations that the 10 μm uncertainty required in the vertical and lateral axes for the fiducialisation of the MBQ can be attained using FSI multilateration.

  15. Continuous-scanning laser Doppler vibrometry: Extensions to arbitrary areas, multi-frequency and 3D capture

    International Nuclear Information System (INIS)

    Weekes, B.; Ewins, D.; Acciavatti, F.

    2014-01-01

    To date, differing implementations of continuous scan laser Doppler vibrometry have been demonstrated by various academic institutions, but since the scan paths were defined using step or sine functions from function generators, the paths were typically limited to 1D line scans or 2D areas such as raster paths or Lissajous trajectories. The excitation was previously often limited to a single frequency due to the specific signal processing performed to convert the scan data into an ODS. In this paper, a configuration of continuous-scan laser Doppler vibrometry is demonstrated which permits scanning of arbitrary areas, with the benefit of allowing multi-frequency/broadband excitation. Various means of generating scan paths to inspect arbitrary areas are discussed and demonstrated. Further, full 3D vibration capture is demonstrated by the addition of a range-finding facility to the described configuration, and iteratively relocating a single scanning laser head. Here, the range-finding facility was provided by a Microsoft Kinect, an inexpensive piece of consumer electronics

  16. Real-Time Imaging with Frequency Scanning Array Antenna for Industrial Inspection Applications at W band

    Science.gov (United States)

    Larumbe, Belen; Laviada, Jaime; Ibáñez-Loinaz, Asier; Teniente, Jorge

    2018-01-01

    A real-time imaging system based on a frequency scanning antenna for conveyor belt setups is presented in this paper. The frequency scanning antenna together with an inexpensive parabolic reflector operates at the W band enabling the detection of details with dimensions in the order of 2 mm. In addition, a low level of sidelobes is achieved by optimizing unequal dividers to window the power distribution for sidelobe reduction. Furthermore, the quality of the images is enhanced by the radiation pattern properties. The performance of the system is validated by showing simulation as well as experimental results obtained in real time, proving the feasibility of these kinds of frequency scanning antennas for cost-effective imaging applications.

  17. On the Frequency Correction in Temperature-Modulated Differential Scanning Calorimetry of Glass Transition

    DEFF Research Database (Denmark)

    Guo, Xiaoju; Mauro, J.C.; Allan, D.C.

    2012-01-01

    Temperature-modulated differential scanning calorimetry (TMDSC) is based on conventional DSC but with a sinusoidally modulated temperature path. Simulations of TMDSC signals were performed for Corning EAGLE XG® glass over a wide range of modulation frequencies. Our results reveal that the frequency...... correction commonly used in the interpretation of TMDSC signals leads to a master nonreversing heat flow curve independent of modulation frequency, provided that sufficiently high frequencies are employed in the TMDSC measurement. A master reversing heat flow curve can also be generated through the frequency...

  18. Improved capacitance sensor with variable operating frequency for scanning capacitance microscopy

    International Nuclear Information System (INIS)

    Kwon, Joonhyung; Kim, Joonhui; Jeong, Jong-Hwa; Lee, Euy-Kyu; Seok Kim, Yong; Kang, Chi Jung; Park, Sang-il

    2005-01-01

    Scanning capacitance microscopy (SCM) has been gaining attention for its capability to measure local electrical properties in doping profile, oxide thickness, trapped charges and charge dynamics. In many cases, stray capacitance produced by different samples and measurement conditions affects the resonance frequency of a capacitance sensor. The applications of conventional SCM are critically limited by the fixed operating frequency and lack of tunability in its SCM sensor. In order to widen SCM application to various samples, we have developed a novel SCM sensor with variable operating frequency. By performing variable frequency sweep over the band of 160 MHz, the SCM sensor is tuned to select the best and optimized resonance frequency and quality factor for each sample measurement. The fundamental advantage of the new variable frequency SCM sensor was demonstrated in the SCM imaging of silicon oxide nano-crystals. Typical sensitivity of the variable frequency SCM sensor was found to be 10 -19 F/V

  19. The correction of vibration in frequency scanning interferometry based absolute distance measurement system for dynamic measurements

    Science.gov (United States)

    Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu

    2015-10-01

    Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.

  20. Self-induced frequency scanning and distributed Bragg reflection in semiconductor lasers with phase-conjugate feedback

    Energy Technology Data Exchange (ETDEWEB)

    Cronin-Golomb; Yariv

    1986-07-01

    A GaA1As semiconductor laser with feedback from a barium titanate photorefractive ring passive phase-conjugate mirror can be made to perform repeating or nonrepeating frequency scans over a 10-nm range toward either the blue or the red. The direction of scanning and whether the scans repeat may be controlled by adjusting the overlap of the interaction beams in the crystal. This overlap region may be adjusted so that the diode frequency spectrum, originally occupying about 10 longitudinal modes, scans and narrows as the conjugate signal builds up, coming to rest often in one, but sometimes two or three, longitudinal modes as a result of self-generated distributed-feedback effects. Also reported similar effects caused by feedback from the total-internal-reflection passive phase-conjugate mirror. The alignment-control mechanism of the ring mirror is, however, not available in this case.

  1. Self-induced frequency scanning and distributed Bragg reflection in semiconductor lasers with phase-conjugate feedback

    Energy Technology Data Exchange (ETDEWEB)

    Cronin-Golomb, M.; Yariv, A.

    1986-07-01

    A GaAlAs semiconductor laser with feedback from a barium titanate photorefractive ring passive phase-conjugate mirror can be made to perform repeating or nonrepeating frequency scans over a 10-nm range toward either the blue or the red. The direction of scanning and whether the scans repeat may be controlled by adjusting the overlap of the interaction beams in the crystal. This overlap region may be adjusted so that the diode frequency spectrum, originally occupying about 10 longitudinal modes, scans and narrows as the conjugate signal builds up, coming to rest often in one, but sometimes two or three, longitudinal modes as a result of self-generated distributed-feedback effects. We also report similar effects caused by feedback from the total-internal-reflection passive phase-conjugate mirror. The alignment-control mechanism of the ring mirror is, however, not available in this case.

  2. Self-induced frequency scanning and distributed bragg reflection in semiconductor lasers with phase-conjugate feedback

    Science.gov (United States)

    Cronin-Golomb, Mark; Yariv, Amnon

    1986-07-01

    A GaAlAs semiconductor laser with feedback from a barium titanate photorefractive ring passive phase-conjugate mirror can be made to perform repeating or nonrepeating frequency scans over a 10-nm range toward either the blue or the red. The direction of scanning and whether the scans repeat may be controlled by adjusting the overlap of the interaction beams in the crystal. This overlap region may be adjusted so that the diode frequency spectrum, originally occupying about 10 longitudinal modes, scans and narrows as the conjugate signal builds up, coming to rest often in one, but sometimes two or three, longitudinal modes as a result of self-generated distributed-feedback effects. We also report similar effects caused by feedback from the total-internal-reflection passive phase-conjugate mirror. The alignment-control mechanism of the ring mirror is, however, not available in this case.

  3. Frequency Response of the Sample Vibration Mode in Scanning Probe Acoustic Microscope

    International Nuclear Information System (INIS)

    Ya-Jun, Zhao; Qian, Cheng; Meng-Lu, Qian

    2010-01-01

    Based on the interaction mechanism between tip and sample in the contact mode of a scanning probe acoustic microscope (SPAM), an active mass of the sample is introduced in the mass-spring model. The tip motion and frequency response of the sample vibration mode in the SPAM are calculated by the Lagrange equation with dissipation function. For the silicon tip and glass assemblage in the SPAM the frequency response is simulated and it is in agreement with the experimental result. The living myoblast cells on the glass slide are imaged at resonance frequencies of the SPAM system, which are 20kHz, 30kHz and 120kHz. It is shown that good contrast of SPAM images could be obtained when the system is operated at the resonance frequencies of the system in high and low-frequency regions

  4. Frequency-scanning MALDI linear ion trap mass spectrometer for large biomolecular ion detection.

    Science.gov (United States)

    Lu, I-Chung; Lin, Jung Lee; Lai, Szu-Hsueh; Chen, Chung-Hsuan

    2011-11-01

    This study presents the first report on the development of a matrix-assisted laser desorption ionization (MALDI) linear ion trap mass spectrometer for large biomolecular ion detection by frequency scan. We designed, installed, and tested this radio frequency (RF) scan linear ion trap mass spectrometer and its associated electronics to dramatically extend the mass region to be detected. The RF circuit can be adjusted from 300 to 10 kHz with a set of operation amplifiers. To trap the ions produced by MALDI, a high pressure of helium buffer gas was employed to quench extra kinetic energy of the heavy ions produced by MALDI. The successful detection of the singly charged secretory immunoglobulin A ions indicates that the detectable mass-to-charge ratio (m/z) of this system can reach ~385 000 or beyond.

  5. Vibration Isolation Study in Scanning Probe Microscopy Part I: Low Frequency

    International Nuclear Information System (INIS)

    Oliva, A.I.; Espinosa-Faller, F.J.; Aguilar, M.

    1998-01-01

    A study of a low frequency isolation device based in a pneumatic system is presented. It consists of four cylinders which are closed and sealed with an elastic membrane on which the load is applied. Each cylinder made of PVC is formed by two chambers divided by a plate with a small hole for communication and damping. Air contained into chambers acts, in combination with the the elastic membranes, as a damper. Scanning probe techniques can be supported by this device in order to reduce the low frequency noises that affects them. Advantages of this isolator are discussed and compared. A theoretical approximation for this model is presented and compared with the experimental results obtained and show that it can isolate noises up to ∼ 2 Hz. The low frequency isolator has stability and fast response to external perturbations. This simple and economical low frequency isolator can be reproduced easily and its design depends on the work specific requirements. (Author) 9 refs

  6. Low temperature laser scanning microscopy of a superconducting radio-frequency cavity

    Science.gov (United States)

    Ciovati, G.; Anlage, Steven M.; Baldwin, C.; Cheng, G.; Flood, R.; Jordan, K.; Kneisel, P.; Morrone, M.; Nemes, G.; Turlington, L.; Wang, H.; Wilson, K.; Zhang, S.

    2012-03-01

    An apparatus was developed to obtain, for the first time, 2D maps of the surface resistance of the inner surface of an operating superconducting radio-frequency niobium cavity by a low-temperature laser scanning microscopy technique. This allows identifying non-uniformities of the surface resistance with a spatial resolution of about 2.4 mm and surface resistance resolution of ˜1 μΩ at 3.3 GHz. A signal-to-noise ratio of about 10 dB was obtained with 240 mW laser power and 1 Hz modulation frequency. The various components of the apparatus, the experimental procedure and results are discussed in detail in this contribution.

  7. Low temperature laser scanning microscopy of a superconducting radio-frequency cavity.

    Science.gov (United States)

    Ciovati, G; Anlage, Steven M; Baldwin, C; Cheng, G; Flood, R; Jordan, K; Kneisel, P; Morrone, M; Nemes, G; Turlington, L; Wang, H; Wilson, K; Zhang, S

    2012-03-01

    An apparatus was developed to obtain, for the first time, 2D maps of the surface resistance of the inner surface of an operating superconducting radio-frequency niobium cavity by a low-temperature laser scanning microscopy technique. This allows identifying non-uniformities of the surface resistance with a spatial resolution of about 2.4 mm and surface resistance resolution of ~1 μΩ at 3.3 GHz. A signal-to-noise ratio of about 10 dB was obtained with 240 mW laser power and 1 Hz modulation frequency. The various components of the apparatus, the experimental procedure and results are discussed in detail in this contribution.

  8. Precursor and Neutral Loss Scans in an RF Scanning Linear Quadrupole Ion Trap

    Science.gov (United States)

    Snyder, Dalton T.; Szalwinski, Lucas J.; Schrader, Robert L.; Pirro, Valentina; Hilger, Ryan; Cooks, R. Graham

    2018-03-01

    Methodology for performing precursor and neutral loss scans in an RF scanning linear quadrupole ion trap is described and compared to the unconventional ac frequency scan technique. In the RF scanning variant, precursor ions are mass selectively excited by a fixed frequency resonance excitation signal at low Mathieu q while the RF amplitude is ramped linearly to pass ions through the point of excitation such that the excited ion's m/z varies linearly with time. Ironically, a nonlinear ac frequency scan is still required for ejection of the product ions since their frequencies vary nonlinearly with the linearly varying RF amplitude. In the case of the precursor scan, the ejection frequency must be scanned so that it is fixed on a product ion m/z throughout the RF scan, whereas in the neutral loss scan, it must be scanned to maintain a constant mass offset from the excited precursor ions. Both simultaneous and sequential permutation scans are possible; only the former are demonstrated here. The scans described are performed on a variety of samples using different ionization sources: protonated amphetamine ions generated by nanoelectrospray ionization (nESI), explosives ionized by low-temperature plasma (LTP), and chemical warfare agent simulants sampled from a surface and analyzed with swab touch spray (TS). We lastly conclude that the ac frequency scan variant of these MS/MS scans is preferred due to electronic simplicity. In an accompanying manuscript, we thus describe the implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 using constant RF voltage. [Figure not available: see fulltext.

  9. Influence of laser frequency noise on scanning Fabry-Perot interferometer based laser Doppler velocimetry

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2014-01-01

    n this work, we study the performance of a scanning Fabry-Perot interferometer based laser Doppler velocimeter (sFPILDV) and compare two candidate 1.5 um single-frequency laser sources for the system – a fiber laser (FL) and a semiconductor laser (SL). We describe a straightforward calibration...... procedure for the sFPI-LDV and investigate the effect of different degrees of laser frequency noise between the FL and the SL on the velocimeter’s performance...

  10. Frequency-scanning interferometry using a time-varying Kalman filter for dynamic tracking measurements.

    Science.gov (United States)

    Jia, Xingyu; Liu, Zhigang; Tao, Long; Deng, Zhongwen

    2017-10-16

    Frequency scanning interferometry (FSI) with a single external cavity diode laser (ECDL) and time-invariant Kalman filtering is an effective technique for measuring the distance of a dynamic target. However, due to the hysteresis of the piezoelectric ceramic transducer (PZT) actuator in the ECDL, the optical frequency sweeps of the ECDL exhibit different behaviors, depending on whether the frequency is increasing or decreasing. Consequently, the model parameters of Kalman filter appear time varying in each iteration, which produces state estimation errors with time-invariant filtering. To address this, in this paper, a time-varying Kalman filter is proposed to model the instantaneous movement of a target relative to the different optical frequency tuning durations of the ECDL. The combination of the FSI method with the time-varying Kalman filter was theoretically analyzed, and the simulation and experimental results show the proposed method greatly improves the performance of dynamic FSI measurements.

  11. Low temperature laser scanning microscopy of a superconducting radio-frequency cavity

    OpenAIRE

    Ciovati, G.; Anlage, Steven M.; Baldwin, C.; Cheng, G.; Flood, R.; Jordan, K.; Kneisel, P.; Morrone, M.; Nemes, G.; Turlington, L.; Wang, H.; Wilson, K.; Zhang, S.

    2012-01-01

    An apparatus was developed to obtain, for the first time, 2D maps of the surface resistance of the inner surface of an operating superconducting radio-frequency niobium cavity by a low-temperature laser scanning microscopy technique. This allows identifying non-uniformities of the surface resistance with a spatial resolution of about one order of magnitude better than with earlier methods and surface resistance resolution of ~ 1 micro-Ohm at 3.3 GHz. A signal-to-noise ratio of about 10 dB was...

  12. Thermal conductivity profile determination in proton-irradiated ZrC by spatial and frequency scanning thermal wave methods

    International Nuclear Information System (INIS)

    Jensen, C.; Chirtoc, M.; Horny, N.; Antoniow, J. S.; Pron, H.; Ban, H.

    2013-01-01

    Using complementary thermal wave methods, the irradiation damaged region of zirconium carbide (ZrC) is characterized by quantifiably profiling the thermophysical property degradation. The ZrC sample was irradiated by a 2.6 MeV proton beam at 600 °C to a dose of 1.75 displacements per atom. Spatial scanning techniques including scanning thermal microscopy (SThM), lock-in infrared thermography (lock-in IRT), and photothermal radiometry (PTR) were used to directly map the in-depth profile of thermal conductivity on a cross section of the ZrC sample. The advantages and limitations of each system are discussed and compared, finding consistent results from all techniques. SThM provides the best resolution finding a very uniform thermal conductivity envelope in the damaged region measuring ∼52 ± 2 μm deep. Frequency-based scanning PTR provides quantification of the thermal parameters of the sample using the SThM measured profile to provide validation of a heating model. Measured irradiated and virgin thermal conductivities are found to be 11.9 ± 0.5 W m −1 K −1 and 26.7 ±1 W m −1 K −1 , respectively. A thermal resistance evidenced in the frequency spectra of the PTR results was calculated to be (1.58 ± 0.1) × 10 −6 m 2 K W −1 . The measured thermal conductivity values compare well with the thermal conductivity extracted from the SThM calibrated signal and the spatially scanned PTR. Combined spatial and frequency scanning techniques are shown to provide a valuable, complementary combination for thermal property characterization of proton-irradiated ZrC. Such methodology could be useful for other studies of ion-irradiated materials

  13. Distinguishing Buried Objects in Extremely Shallow Underground by Frequency Response Using Scanning Laser Doppler Vibrometer

    Science.gov (United States)

    Touma Abe,; Tsuneyoshi Sugimoto,

    2010-07-01

    A sound wave vibration using a scanning laser Doppler vibrometer are used as a method of exploring and imaging an extremely shallow underground. Flat speakers are used as a vibration source. We propose a method of distinguishing a buried object using a response range of a frequencies corresponding to a vibration velocities. Buried objects (plastic containers, a hollow steel can, an unglazed pot, and a stone) are distinguished using a response range of frequencies. Standardization and brightness imaging are used as methods of discrimination. As a result, it was found that the buried objects show different response ranges of frequencies. From the experimental results, we confirmed the effectiveness of our proposed method.

  14. Suppressing self-induced frequency scanning of a phase conjugate diode laser array with using counterbalance dispersion

    DEFF Research Database (Denmark)

    Løbel, M.; Petersen, P.M.; Johansen, P.M.

    1998-01-01

    Experimental results show that angular dispersion strongly influences the self-induced frequency scanning of a multimode broad-area diode laser array coupled to a photorefractive self-pumped phase conjugate mirror. Prisms or a dispersive grating placed in the external cavity opposing the material...

  15. Precision controlled atomic resolution scanning transmission electron microscopy using spiral scan pathways

    Science.gov (United States)

    Sang, Xiahan; Lupini, Andrew R.; Ding, Jilai; Kalinin, Sergei V.; Jesse, Stephen; Unocic, Raymond R.

    2017-03-01

    Atomic-resolution imaging in an aberration-corrected scanning transmission electron microscope (STEM) can enable direct correlation between atomic structure and materials functionality. The fast and precise control of the STEM probe is, however, challenging because the true beam location deviates from the assigned location depending on the properties of the deflectors. To reduce these deviations, i.e. image distortions, we use spiral scanning paths, allowing precise control of a sub-Å sized electron probe within an aberration-corrected STEM. Although spiral scanning avoids the sudden changes in the beam location (fly-back distortion) present in conventional raster scans, it is not distortion-free. “Archimedean” spirals, with a constant angular frequency within each scan, are used to determine the characteristic response at different frequencies. We then show that such characteristic functions can be used to correct image distortions present in more complicated constant linear velocity spirals, where the frequency varies within each scan. Through the combined application of constant linear velocity scanning and beam path corrections, spiral scan images are shown to exhibit less scan distortion than conventional raster scan images. The methodology presented here will be useful for in situ STEM imaging at higher temporal resolution and for imaging beam sensitive materials.

  16. Rapid-scan EPR imaging.

    Science.gov (United States)

    Eaton, Sandra S; Shi, Yilin; Woodcock, Lukas; Buchanan, Laura A; McPeak, Joseph; Quine, Richard W; Rinard, George A; Epel, Boris; Halpern, Howard J; Eaton, Gareth R

    2017-07-01

    In rapid-scan EPR the magnetic field or frequency is repeatedly scanned through the spectrum at rates that are much faster than in conventional continuous wave EPR. The signal is directly-detected with a mixer at the source frequency. Rapid-scan EPR is particularly advantageous when the scan rate through resonance is fast relative to electron spin relaxation rates. In such scans, there may be oscillations on the trailing edge of the spectrum. These oscillations can be removed by mathematical deconvolution to recover the slow-scan absorption spectrum. In cases of inhomogeneous broadening, the oscillations may interfere destructively to the extent that they are not visible. The deconvolution can be used even when it is not required, so spectra can be obtained in which some portions of the spectrum are in the rapid-scan regime and some are not. The technology developed for rapid-scan EPR can be applied generally so long as spectra are obtained in the linear response region. The detection of the full spectrum in each scan, the ability to use higher microwave power without saturation, and the noise filtering inherent in coherent averaging results in substantial improvement in signal-to-noise relative to conventional continuous wave spectroscopy, which is particularly advantageous for low-frequency EPR imaging. This overview describes the principles of rapid-scan EPR and the hardware used to generate the spectra. Examples are provided of its application to imaging of nitroxide radicals, diradicals, and spin-trapped radicals at a Larmor frequency of ca. 250MHz. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Simulation of multicomponent losses in electron beam melting and refining at varying scan frequencies

    International Nuclear Information System (INIS)

    Powell, A.; Szekely, J.; Van Den Avyle, J.; Damkroger, B.

    1995-01-01

    A two-stage model is presented to describe alloy element evaporation rates from molten metal due to transient local heating by an electron beam. The first stage is a simulation of transient phenomena near the melt surface due to periodic heating by a scanning beam, the output of which is the relationship between operating parameters, surface temperature, and evaporation rate. At high scan rates, this can be done using a simple one-dimensional heat transfer model of the surface layer; at lower scan rates, a more complex three-dimensional model with fluid flow and periodic boundary conditions is necessary. The second stage couples this evaporation-surface temperature relationship with a larger steady state heat transfer and fluid flow model of an entire melting hearth or mold, in order to calculate local and total evaporation rates. Predictions are compared with experimental results from Sandia's 310-kW electron beam melting furnace, in which evaporation rates and vapor compositions were studied in pure titanium and Ti-6%Al-4%V alloy. Evaporation rates were estimated from rate of condensation on a substrate held over the hearth, and were characterized as a function of beam power (150 and 225 kW), scan frequency (30, 115 and 450 Hz) and background pressure (10 -3 , 10 -4 and 10 -5 torr)

  18. Simultaneously measured signals in scanning probe microscopy with a needle sensor: frequency shift and tunneling current.

    Science.gov (United States)

    Morawski, Ireneusz; Voigtländer, Bert

    2010-03-01

    We present combined noncontact scanning force microscopy and tunneling current images of a platinum(111) surface obtained by means of a 1 MHz quartz needle sensor. The low-frequency circuit of the tunneling current was combined with a high-frequency signal of the quartz resonator enabling full electrical operation of the sensor. The frequency shift and the tunneling current were detected simultaneously, while the feedback control loop of the topography signal was fed using one of them. In both cases, the free signal that was not connected to the feedback loop reveals proportional-integral controller errorlike behavior, which is governed by the time derivative of the topography signal. A procedure is proposed for determining the mechanical oscillation amplitude by utilizing the tunneling current also including the average tip-sample work function.

  19. Influence of PET/CT-introduction on PET scanning frequency and indications. Results of a multicenter study

    International Nuclear Information System (INIS)

    Stergar, H.; Bockisch, A.; Eschmann, S.M.; Krause, B.J.; Roedel, R.; Tiling, R.; Weckesser, M.

    2007-01-01

    Aim: to evaluate the influence of the introduction of combined PET/CT scanners into clinical routine. This investigation addresses the quantitative changes between PET/CT and stand alone PET. Methods: the study included all examinations performed on stand alone PET- or PET/CT-scanners within 12 month prior to and after implementation of PET/CT. The final data analysis included five university hospitals and a total number of 15 497 exams. We distinguished exams on stand alone tomographs prior to and after installation of the combined device as well as PET/CT scans particularly with regard to disease entities. Various further parameters were investigated. Results: the overall number of PET scans (PET and PET/CT) rose by 146% while the number of scans performed on stand alone scanners declined by 22%. Only one site registered an increase in stand alone PET. The number of exams for staging in oncology increased by 196% while that of cardiac scans decreased by 35% and the number of scans in neurology rose by 47%. The use of scans for radiotherapy planning increased to 7% of all PET/CT studies. The increase of procedures for so-called classic PET oncology indications was moderate compared to the more common tumors. An even greater increase was observed in some rare entities. Conclusions: the introduction of PET/CT led to more than a doubling of overall PET procedures with a main focus on oncology. Some of the observed changes in scanning frequency may be caused by a rising availability of new radiotracers and advancements of competing imaging methods. Nevertheless the evident increase in the use of PET/CT for the most common tumour types demonstrates its expanding role in cancer staging. The combination of molecular and morphologic imaging has not only found its place but is still gaining greater importance with new developments in technology and radiochemistry. (orig.)

  20. Barrido de frecuencia en coordenadas de fase Frequency scan on phase-coordinates

    Directory of Open Access Journals (Sweden)

    Ignacio Pérez Abril

    2012-02-01

    Full Text Available El análisis de redes eléctricas ha transitado de modelos en componentes de secuencia a modelos en coordenadas de fase. La formulación del barrido de frecuencia en coordenadas de fase, además de facilitar la modelación más precisa de las redes desequilibradas, permite especificar inyecciones armónicas de cualquier tipo: monofásicas o trifásicas de la secuencia deseada. Por lo que puede estudiarse el efecto de las cargas no lineales de acuerdo a sus características y conexión al circuito. El presente trabajo desarrolla el modelo en coordenadas de fase de una red eléctrica, considerando la representación de bancos de transformadores monofásicos de tres o dos transformadores, así como otros tipos de asimetrías que pueden encontrarse en los sistemas eléctricos de instalaciones industriales, de edificios comerciales o de servicio. El modelo desarrollado se prueba con un ejemplo sencillo de un sistema delta a cuatro hilos que permite destacar las posibilidades del modelo.The electric networks analysis has upgraded from the sequence components frame models to the phase- coordinates frame models. The formulation of the frequency scan method in a phase- coordinates frame, besides allowing for a more accurate modeling of unbalanced networks, allows the specification of harmonic injections of any type: single-phase or three-phase of the desired sequence. Therefore, it is possible to study the effect of the non-linear loads according to its features and connection to the circuit. This paper develops the phase-coordinates model of a distribution power system, considering the representation of three-phase transformer banks of three or two single-phase transformers, as well as other asymmetries that can be found in the electrical systems of industrial plants, commercial or service facilities. The frequency scan based on the presented model is tested with a simple example of a four-wire delta system that highlights the possibilities of the model

  1. Barrido de frecuencia en coordenadas de fase; Frequency scan on phase-coordinates

    Directory of Open Access Journals (Sweden)

    Ignacio Pérez Abril

    2014-04-01

    Full Text Available El análisis de redes eléctricas ha transitado de modelos en componentes de secuencia a modelos en coordenadas de fase. La formulación del barrido de frecuencia en coordenadas de fase, además de facilitar la modelación más precisa de las redes desequilibradas, permite especificar inyecciones armónicas de cualquier tipo: monofásicas o trifásicas de la secuencia deseada. Por lo que puede estudiarse el efecto de las cargas no lineales de acuerdo a sus características y conexión al circuito. El presente trabajo desarrolla el modelo en coordenadas de fase de una red eléctrica, considerando la representación de bancos de transformadores monofásicos de tres o dos transformadores, así como otros tipos de asimetrías que pueden encontrarse en los sistemas eléctricos de instalaciones industriales, de edificios comerciales o de servicio. El modelo desarrollado se prueba con un ejemplo sencillo de un sistema delta a cuatro hilos que permite destacar las posibilidades del modelo.  The electric networks analysis has upgraded from the sequence components frame models to the phase- coordinates frame models. The formulation of the frequency scan method in a phase- coordinates frame, besides allowing for a more accurate modeling of unbalanced networks, allows the specification of harmonic injections of any type: single-phase or three-phase of the desired sequence. Therefore, it is possible to study the effect of the non-linear loads according to its features and connection to the circuit. This paper develops the phase-coordinates model of a distribution power system, considering the representation of three-phase transformer banks of three or two single-phase transformers, as well as other asymmetries that can be found in the electrical systems of industrial plants, commercial or service facilities. The frequency scan based on the presented model is tested with a simple example of a four-wire delta system that highlights the possibilities of the

  2. Mapping of trap densities and hotspots in pentacene thin-film transistors by frequency-resolved scanning photoresponse microscopy.

    Science.gov (United States)

    Westermeier, Christian; Fiebig, Matthias; Nickel, Bert

    2013-10-25

    Frequency-resolved scanning photoresponse microscopy of pentacene thin-film transistors is reported. The photoresponse pattern maps the in-plane distribution of trap states which is superimposed by the level of trap filling adjusted by the gate voltage of the transistor. Local hotspots in the photoresponse map thus indicate areas of high trap densities within the pentacene thin film. © 2013 WILEY-VCH Verlag GmbH 8 Co. KGaA, Weinheim.

  3. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  4. LIDAR COMBINED SCANNING UNIT

    Directory of Open Access Journals (Sweden)

    V. V. Elizarov

    2016-11-01

    Full Text Available Subject of Research. The results of lidar combined scanning unit development for locating leaks of hydrocarbons are presented The unit enables to perform high-speed scanning of the investigated space in wide and narrow angle fields. Method. Scanning in a wide angular field is produced by one-line scanning path by means of the movable aluminum mirror with a frequency of 20Hz and amplitude of 20 degrees of swing. Narrowband scanning is performed along a spiral path by the deflector. The deflection of the beam is done by rotation of the optical wedges forming part of the deflector at an angle of ±50. The control function of the scanning node is performed by a specialized software product written in C# programming language. Main Results. This scanning unit allows scanning the investigated area at a distance of 50-100 m with spatial resolution at the level of 3 cm. The positioning accuracy of the laser beam in space is 15'. The developed scanning unit gives the possibility to browse the entire investigated area for the time not more than 1 ms at a rotation frequency of each wedge from 50 to 200 Hz. The problem of unambiguous definition of the beam geographical coordinates in space is solved at the software level according to the rotation angles of the mirrors and optical wedges. Lidar system coordinates are determined by means of GPS. Practical Relevance. Development results open the possibility for increasing the spatial resolution of scanning systems of a wide range of lidars and can provide high positioning accuracy of the laser beam in space.

  5. Assessment of breast tumor size in electrical impedance scanning

    International Nuclear Information System (INIS)

    Kim, Sungwhan

    2012-01-01

    Electrical impedance scanning (EIS) is a newly introduced imaging technique for early breast cancer detection. In EIS, we apply a sinusoidal voltage between a hand-held electrode and a scanning probe placed on the breast skin to make current travel through the breast. We measure induced currents (Neumann data) through the scanning probe. In this paper, we investigate the frequency-dependent behavior of the induced complex potential and show how the frequency differential of the current measurement on the scanning probe reflects the contrast in complex conductivity values between surrounding and cancerous tissues. Furthermore, we develop the formula for breast tumor size using the frequency differential of the current measurement and provide its feasibility. (paper)

  6. A scanning Auger electron spectrometer for internal surface analysis of Large Electron Positron 2 superconducting radio-frequency cavities

    Science.gov (United States)

    Benvenuti, C.; Cosso, R.; Genest, J.; Hauer, M.; Lacarrère, D.; Rijllart, A.; Saban, R.

    1996-08-01

    A computer-controlled surface analysis instrument, incorporating static Auger electron spectroscopy, scanning Auger mapping, and secondary electron imaging, has been designed and built at CERN to study and characterize the inner surface of superconducting radio-frequency cavities to be installed in the Large Electron Positron collider. A detailed description of the instrument, including the analytical head, the control system, and the vacuum system is presented. Some recent results obtained from the cavities provide examples of the instrument's capabilities.

  7. Scanning Terahertz Heterodyne Imaging Systems

    Science.gov (United States)

    Siegel, Peter; Dengler, Robert

    2007-01-01

    Scanning terahertz heterodyne imaging systems are now at an early stage of development. In a basic scanning terahertz heterodyne imaging system, (see Figure 1) two far-infrared lasers generate beams denoted the local-oscillator (LO) and signal that differ in frequency by an amount, denoted the intermediate frequency (IF), chosen to suit the application. The LO beam is sent directly to a mixer as one of two inputs. The signal beam is focused to a spot on or in the specimen. After transmission through or reflection from the specimen, the beams are focused to a spot on a terahertz mixer, which extracts the IF outputs. The specimen is mounted on a translation stage, by means of which the focal spot is scanned across the specimen to build up an image.

  8. Improved path imbalance measurement of a fiber-optic interferometer based on frequency scanning interferometry

    International Nuclear Information System (INIS)

    Hou, C B; Wang, J G; Yang, J; Li, H Y; Peng, F; Yuan, L B; Yuan, Y G

    2017-01-01

    We developed a path imbalance measuring system using a reference interferometer with alterable optical path difference (OPD), aiming to eliminate the uncertainties due to synthetic wavelength measurement and remove the requirement of a known and stable reference OPD in frequency scanning interferometry. The path imbalance can be solved by using the phase ratios between the two interferometers produced before and after altering the OPD in the reference interferometer. The results have shown that the measurement uncertainty and the path imbalance are linearly related and a combined relative uncertainty of 4.9  ×  10 −6 (1 σ ) in path imbalance measurement over a range from 0.5 m to 50 m is achieved. Besides, we analyzed the contributions to the uncertainty that limit the performance of the system, and we discussed how to obtain a better measurement uncertainty. (paper)

  9. Local impedance measurement of an electrode/single-pentacene-grain interface by frequency-modulation scanning impedance microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Tomoharu; Yamada, Hirofumi, E-mail: h-yamada@kuee.kyoto-u.ac.jp [Department of Electronic Science and Engineering, Kyoto University, Kyoto 615-8510 (Japan); Kobayashi, Kei [Department of Electronic Science and Engineering, Kyoto University, Kyoto 615-8510 (Japan); The Hakubi Center for Advanced Research, Kyoto University, Kyoto 615-8520 (Japan)

    2015-08-07

    The device performances of organic thin film transistors are often limited by the metal–organic interface because of the disordered molecular layers at the interface and the energy barriers against the carrier injection. It is important to study the local impedance at the interface without being affected by the interface morphology. We combined frequency modulation atomic force microscopy with scanning impedance microscopy (SIM) to sensitively measure the ac responses of the interface to an ac voltage applied across the interface and the dc potential drop at the interface. By using the frequency-modulation SIM (FM-SIM) technique, we characterized the interface impedance of a Pt electrode and a single pentacene grain as a parallel circuit of a contact resistance and a capacitance. We found that the reduction of the contact resistance was caused by the reduction of the energy level mismatch at the interface by the FM-SIM measurements, demonstrating the usefulness of the FM-SIM technique for investigation of the local interface impedance without being affected by its morphology.

  10. Full cycle rapid scan EPR deconvolution algorithm.

    Science.gov (United States)

    Tseytlin, Mark

    2017-08-01

    Rapid scan electron paramagnetic resonance (RS EPR) is a continuous-wave (CW) method that combines narrowband excitation and broadband detection. Sinusoidal magnetic field scans that span the entire EPR spectrum cause electron spin excitations twice during the scan period. Periodic transient RS signals are digitized and time-averaged. Deconvolution of absorption spectrum from the measured full-cycle signal is an ill-posed problem that does not have a stable solution because the magnetic field passes the same EPR line twice per sinusoidal scan during up- and down-field passages. As a result, RS signals consist of two contributions that need to be separated and postprocessed individually. Deconvolution of either of the contributions is a well-posed problem that has a stable solution. The current version of the RS EPR algorithm solves the separation problem by cutting the full-scan signal into two half-period pieces. This imposes a constraint on the experiment; the EPR signal must completely decay by the end of each half-scan in order to not be truncated. The constraint limits the maximum scan frequency and, therefore, the RS signal-to-noise gain. Faster scans permit the use of higher excitation powers without saturating the spin system, translating into a higher EPR sensitivity. A stable, full-scan algorithm is described in this paper that does not require truncation of the periodic response. This algorithm utilizes the additive property of linear systems: the response to a sum of two inputs is equal the sum of responses to each of the inputs separately. Based on this property, the mathematical model for CW RS EPR can be replaced by that of a sum of two independent full-cycle pulsed field-modulated experiments. In each of these experiments, the excitation power equals to zero during either up- or down-field scan. The full-cycle algorithm permits approaching the upper theoretical scan frequency limit; the transient spin system response must decay within the scan

  11. Calibrated complex impedance of CHO cells and E. coli bacteria at GHz frequencies using scanning microwave microscopy

    International Nuclear Information System (INIS)

    Tuca, Silviu-Sorin; Gramse, Georg; Kasper, Manuel; Oh, Yoo Jin; Zhu, Rong; Hinterdorfer, Peter; Badino, Giorgio; Brinciotti, Enrico; Rankl, Christian; Kienberger, Ferry

    2016-01-01

    The application of scanning microwave microscopy (SMM) to extract calibrated electrical properties of cells and bacteria in air is presented. From the S _1_1 images, after calibration, complex impedance and admittance images of Chinese hamster ovary cells and E. coli bacteria deposited on a silicon substrate have been obtained. The broadband capabilities of SMM have been used to characterize the bio-samples between 2 GHz and 20 GHz. The resulting calibrated cell and bacteria admittance at 19 GHz were Y _c_e_l_l = 185 μS + j285 μS and Y _b_a_c_t_e_r_i_a = 3 μS + j20 μS, respectively. A combined circuitry-3D finite element method EMPro model has been developed and used to investigate the frequency response of the complex impedance and admittance of the SMM setup. Based on a proposed parallel resistance–capacitance model, the equivalent conductance and parallel capacitance of the cells and bacteria were obtained from the SMM images. The influence of humidity and frequency on the cell conductance was experimentally studied. To compare the cell conductance with bulk water properties, we measured the imaginary part of the bulk water loss with a dielectric probe kit in the same frequency range resulting in a high level of agreement. (paper)

  12. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  13. Vibrating wire for beam profile scanning

    Directory of Open Access Journals (Sweden)

    S. G. Arutunian

    1999-12-01

    Full Text Available A method that measures the transverse profile (emittance of the bunch by detecting radiation arising at the scattering of the bunch on scanning wire is widely used. In this work information about bunch scattering is obtained by measuring the oscillation frequency of the tightened scanning wire. In such a way, the system of radiation (or secondary particles extraction and measurement can be removed. The entire unit consists of a compact fork with tightened wire and a scanning system. Normal oscillation frequency of a wire depends on wire tension, its geometric parameters, and, in a second approximation, its elastic characteristics. Normal oscillations are generated by interaction of an alternating current through the wire with magnetic field of a permanent magnet. In this case, it is suggested that the magnetic field of the accelerator (field of dipole magnets or quadrupole magnets be used for excitation of oscillations. The dependence of oscillation frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam and influence of beam self-field. Preliminary calculations show that the influence of wire heating will dominate. We have studied strain gauges on the basis of vibrating wire from various materials (tungsten, beryl bronze, and niobium zirconium alloys. A scheme of normal oscillation generation by alternating current in autogeneration circuit with automatic frequency adjustment was selected. A special method of wire fixation and elimination of transverse degrees of freedom allows us to achieve relative stability better than 10^{-5} during several days at a relative resolution of 10^{-6}. Experimental results and estimates of wire heating of existing scanners show that the wire heats up to a few hundred grades, which is enough for measurements. The usage of wire of micrometer thickness diminishes the problem of wire thermalization speed during the scanning of the bunch.

  14. Dynamic phasor based frequency scanning for grid-connected ...

    Indian Academy of Sciences (India)

    M K Das

    2017-10-11

    Oct 11, 2017 ... situations, it is not so for systems with low-order harmonics, individual-phase schemes, unbalanced or single- ..... rents at x А 2xo and x, respectively, due to the fundamental ... c = xot, where xo is the operating frequency.

  15. CAMAC programmable-control frequency synthesizer

    International Nuclear Information System (INIS)

    Yumaguzin, T.Kh.; Vyazovkin, D.E.; Nazirov, Eh.P.; Tuktarov, R.F.

    1989-01-01

    Synthesizer allows to set frequency with 0.015% accuracy and to scan it with variable step. Frequency controlled divider with further summing-up of divided frequency with fundamental one is used in synthesizer, and it has allowed to use digit of the input code and to obtain 3-4 MHz frequency range. Variation of operation flowsheet in the other frequency range is possible. K-155 and K-531 series microcircuits were used during development

  16. Bone scanning as a routine examination of patients with mammary carcinoma; a critical consideration. [Preoperative scanning

    Energy Technology Data Exchange (ETDEWEB)

    Heslinga, J M; Pauwels, E K.J.; Zwaveling, A [Rijksuniversiteit Leiden (Netherlands). Academisch Ziekenhuis

    1982-06-05

    The usefulness of bone scanning as a routine examination was evaluated in 136 female patients with mammary carcinoma of whom 81 were staged as Columbia A and 55 as Columbia B/C. The preoperative bone scanning was positive in only 4 patients (2.9%). Consequently, bone scanning is no longer performed in the authors clinic for the preoperative detection of skeletal metastases. Bone scanning as a routine examination at 6-month intervals does not appear to be useful for the first 4 years of the follow-up, either. Most of the patients with a positive bone scan displayed other signs of skeletal metastases at the same time, such as ostealgia and a raised serum alkaline phosphatase level. Further increase of the frequency of bone scanning during the follow-up period would increase the costs considerably, almost prohibitively, even apart from the question whether such a measure might indeed significantly influence the patient's prognosis. The authors conclude that bone scanning should only be performed on the basis of the anamnesis, physical and laboratory findings, both prior to operation and during the follow-up period.

  17. Combining Frequency Doubling Technology Perimetry and Scanning Laser Polarimetry for Glaucoma Detection.

    Science.gov (United States)

    Mwanza, Jean-Claude; Warren, Joshua L; Hochberg, Jessica T; Budenz, Donald L; Chang, Robert T; Ramulu, Pradeep Y

    2015-01-01

    To determine the ability of frequency doubling technology (FDT) and scanning laser polarimetry with variable corneal compensation (GDx-VCC) to detect glaucoma when used individually and in combination. One hundred ten normal and 114 glaucomatous subjects were tested with FDT C-20-5 screening protocol and the GDx-VCC. The discriminating ability was tested for each device individually and for both devices combined using GDx-NFI, GDx-TSNIT, number of missed points of FDT, and normal or abnormal FDT. Measures of discrimination included sensitivity, specificity, area under the curve (AUC), Akaike's information criterion (AIC), and prediction confidence interval lengths. For detecting glaucoma regardless of severity, the multivariable model resulting from the combination of GDx-TSNIT, number of abnormal points on FDT (NAP-FDT), and the interaction GDx-TSNIT×NAP-FDT (AIC: 88.28, AUC: 0.959, sensitivity: 94.6%, specificity: 89.5%) outperformed the best single-variable model provided by GDx-NFI (AIC: 120.88, AUC: 0.914, sensitivity: 87.8%, specificity: 84.2%). The multivariable model combining GDx-TSNIT, NAP-FDT, and interaction GDx-TSNIT×NAP-FDT consistently provided better discriminating abilities for detecting early, moderate, and severe glaucoma than the best single-variable models. The multivariable model including GDx-TSNIT, NAP-FDT, and the interaction GDx-TSNIT×NAP-FDT provides the best glaucoma prediction compared with all other multivariable and univariable models. Combining the FDT C-20-5 screening protocol and GDx-VCC improves glaucoma detection compared with using GDx or FDT alone.

  18. MutScan: fast detection and visualization of target mutations by scanning FASTQ data.

    Science.gov (United States)

    Chen, Shifu; Huang, Tanxiao; Wen, Tiexiang; Li, Hong; Xu, Mingyan; Gu, Jia

    2018-01-22

    Some types of clinical genetic tests, such as cancer testing using circulating tumor DNA (ctDNA), require sensitive detection of known target mutations. However, conventional next-generation sequencing (NGS) data analysis pipelines typically involve different steps of filtering, which may cause miss-detection of key mutations with low frequencies. Variant validation is also indicated for key mutations detected by bioinformatics pipelines. Typically, this process can be executed using alignment visualization tools such as IGV or GenomeBrowse. However, these tools are too heavy and therefore unsuitable for validating mutations in ultra-deep sequencing data. We developed MutScan to address problems of sensitive detection and efficient validation for target mutations. MutScan involves highly optimized string-searching algorithms, which can scan input FASTQ files to grab all reads that support target mutations. The collected supporting reads for each target mutation will be piled up and visualized using web technologies such as HTML and JavaScript. Algorithms such as rolling hash and bloom filter are applied to accelerate scanning and make MutScan applicable to detect or visualize target mutations in a very fast way. MutScan is a tool for the detection and visualization of target mutations by only scanning FASTQ raw data directly. Compared to conventional pipelines, this offers a very high performance, executing about 20 times faster, and offering maximal sensitivity since it can grab mutations with even one single supporting read. MutScan visualizes detected mutations by generating interactive pile-ups using web technologies. These can serve to validate target mutations, thus avoiding false positives. Furthermore, MutScan can visualize all mutation records in a VCF file to HTML pages for cloud-friendly VCF validation. MutScan is an open source tool available at GitHub: https://github.com/OpenGene/MutScan.

  19. Hypodense regions (holes) in the retinal nerve fiber layer in frequency-domain OCT scans of glaucoma patients and suspects.

    Science.gov (United States)

    Xin, Daiyan; Talamini, Christine L; Raza, Ali S; de Moraes, Carlos Gustavo V; Greenstein, Vivienne C; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C

    2011-09-09

    To better understand hypodense regions (holes) that appear in the retinal nerve fiber layer (RNFL) of frequency-domain optical coherence tomography (fdOCT) scans of patients with glaucoma and glaucoma suspects. Peripapillary circle (1.7-mm radius) and cube optic disc fdOCT scans were obtained on 208 eyes from 110 patients (57.4 ± 13.2 years) with glaucomatous optic neuropathy (GON) and 45 eyes of 45 controls (48.0 ± 12.6 years) with normal results of fundus examination. Holes in the RNFL were identified independently by two observers on the circle scans. Holes were found in 33 (16%) eyes of 28 (25%) patients; they were not found in any of the control eyes. Twenty-four eyes had more than one hole. Although some holes were relatively large, others were small. In general, the holes were located adjacent to blood vessels; only three eyes had isolated holes that were not adjacent to a vessel. The holes tended to be in the regions that are thickest in healthy controls and were associated with arcuate defects in patients. Holes were not seen in the center of the temporal disc region. They were more common in the superior (25 eyes) than in the inferior (15 eyes) disc. Of the 30 eyes with holes with reliable visual fields, seven were glaucoma suspect eyes with normal visual fields. The holes in the RNFL seen in patients with GON were probably due to a local loss of RNFL fibers and can occur in the eyes of glaucoma suspects with normal visual fields.

  20. Identification of damage in plates using full-field measurement with a continuously scanning laser Doppler vibrometer system

    Science.gov (United States)

    Chen, Da-Ming; Xu, Y. F.; Zhu, W. D.

    2018-05-01

    An effective and reliable damage identification method for plates with a continuously scanning laser Doppler vibrometer (CSLDV) system is proposed. A new constant-speed scan algorithm is proposed to create a two-dimensional (2D) scan trajectory and automatically scan a whole plate surface. Full-field measurement of the plate can be achieved by applying the algorithm to the CSLDV system. Based on the new scan algorithm, the demodulation method is extended from one dimension for beams to two dimensions for plates to obtain a full-field operating deflection shape (ODS) of the plate from velocity response measured by the CSLDV system. The full-field ODS of an associated undamaged plate is obtained by using polynomials with proper orders to fit the corresponding full-field ODS from the demodulation method. A curvature damage index (CDI) using differences between curvatures of ODSs (CODSs) associated with ODSs that are obtained by the demodulation method and the polynomial fit is proposed to identify damage. An auxiliary CDI obtained by averaging CDIs at different excitation frequencies is defined to further assist damage identification. An experiment of an aluminum plate with damage in the form of 10.5% thickness reduction in a damage area of 0.86% of the whole scan area is conducted to investigate the proposed method. Six frequencies close to natural frequencies of the plate and one randomly selected frequency are used as sinusoidal excitation frequencies. Two 2D scan trajectories, i.e., a horizontally moving 2D scan trajectory and a vertically moving 2D scan trajectory, are used to obtain ODSs, CODSs, and CDIs of the plate. The damage is successfully identified near areas with consistently high values of CDIs at different excitation frequencies along the two 2D scan trajectories; the damage area is also identified by auxiliary CDIs.

  1. Double-polarizating scanning radiometer

    International Nuclear Information System (INIS)

    Mishev, D.N.; Nazyrski, T.G.

    1986-01-01

    The double-polarizating single-channel scanning radiometer comprises the following serial connected parts: a scanning double-polarizating aerial, a block for polarization separation, a radiometer receiver, an analog-to-digit converter and an information flow forming block. The low frequency input of the radiometer receiver is connected with a control block, which is also connected with a first bus of a microprocessor, the second bus of which is connected with the A-D converter. The control input of the scanning double-polarizating aerial is connected with the first microprocessor bus. The control inputs of the block for polarization separation are linked by an electronic switch with the output of the forming block, the input of which is connected to the first input of the control block. The control inputs of the block for polarization separation are connected with the second and the third input of the information flow forming block. 2 cls

  2. Single- and multi-frequency detection of surface displacements via scanning probe microscopy.

    Science.gov (United States)

    Romanyuk, Konstantin; Luchkin, Sergey Yu; Ivanov, Maxim; Kalinin, Arseny; Kholkin, Andrei L

    2015-02-01

    Piezoresponse force microscopy (PFM) provides a novel opportunity to detect picometer-level displacements induced by an electric field applied through a conducting tip of an atomic force microscope (AFM). Recently, it was discovered that superb vertical sensitivity provided by PFM is high enough to monitor electric-field-induced ionic displacements in solids, the technique being referred to as electrochemical strain microscopy (ESM). ESM has been implemented only in multi-frequency detection modes such as dual AC resonance tracking (DART) and band excitation, where the response is recorded within a finite frequency range, typically around the first contact resonance. In this paper, we analyze and compare signal-to-noise ratios of the conventional single-frequency method with multi-frequency regimes of measuring surface displacements. Single-frequency detection ESM is demonstrated using a commercial AFM.

  3. Improving the scanning speed of atomic force microscopy at the scanning range of several tens of micrometers

    International Nuclear Information System (INIS)

    Wang, Yanyan; Hu, Xiaodong; Xu, Linyan; Hu, Xiaotang

    2013-01-01

    The atomic force microscope (AFM) is a powerful instrument which can measure the surface of samples at the nanoscale. The resonance of the scanner in xy directions, and the feedback control in the z direction are two major sources of image distortion at high scan speed. In order to improve the scanning speed of the AFM, a low-cost and easy method, which includes sinusoidal scans in the fast scan direction, and an intelligent fuzzy controller in the z direction, is proposed in this paper. The use of a single-frequency driving signal in the fast scan direction allows the scanner to move at a higher speed without exciting its mechanical resonance. The intelligent fuzzy controller automatically selects appropriate PI parameters through the analysis of the tracking errors, thus improving the dynamic tracking performance of the z scanner. The development and functioning of the sinusoidal fast scans and the intelligent fuzzy controller are demonstrated, as well as how this approach significantly achieves faster scans and a higher resolution AFM imaging. -- Highlights: ► The sinusoidal scan and the intelligent controller are used to improve AFM's rate. ► A new method is raised to overcome the nonlinearity caused by the sinusoidal scan. ► A new controller is proposed to improve the performance of the vertical direction.

  4. The distinguishing effects of low-intensity electromagnetic radiation of different extremely high frequencies on Enterococcus hirae: growth rate inhibition and scanning electron microscopy analysis.

    Science.gov (United States)

    Hovnanyan, K; Kalantaryan, V; Trchounian, A

    2017-09-01

    A low-intensity electromagnetic field of extremely high frequency has inhibitory and stimulatory effects on bacteria, including Enterococcus hirae. It was shown that the low-intensity (the incident power density of 0·06 mW cm -2 ) electromagnetic field at the frequencies of 51·8 GHz and 53 GHz inhibited E. hirae ATCC 9790 bacterial growth rate; a stronger effect was observed with 53 GHz, regardless of exposure duration (0·5 h, 1 h or 2 h). Scanning electron microscopy analysis of these effects has been done; the cells were of spherical shape. Electromagnetic field at 53 GHz, but not 51·8 GHz, changed the cell size-the diameter was enlarged 1·3 fold at 53 GHz. These results suggest the difference in mechanisms of action on bacteria for electromagnetic fields at 51·8 GHz and 53 GHz. A stronger inhibitory effect of low-intensity electromagnetic field on Enterococcus hirae ATCC 9790 bacterial growth rate was observed with 53 GHz vs 51·8 GHz, regardless of exposure duration. Scanning electron microscopy analysis showed that almost all irradiated cells in the population have spherical shapes similar to nonirradiated ones, but they have increased diameters in case of irradiated cells at 53 GHz, but not 51·8 GHz. The results are novel, showing distinguishing effects of low-intensity electromagnetic field of different frequencies. They could be applied in treatment of food and different products in medicine and veterinary, where E. hirae plays an important role. © 2017 The Society for Applied Microbiology.

  5. Variants and pitfalls on radioiodine scans in pediatric patients with differentiated thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Mostafa, Mohamed; Vali, Reza; Chan, Jeffrey; Omarkhail, Yusuaf; Shammas, Amer [University of Toronto, Nuclear Medicine Division, Department of Medical Imaging, The Hospital for Sick Children, Toronto, Ontario (Canada)

    2016-10-15

    Potentially false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma can mimic functioning thyroid tissue and functioning thyroid carcinomatous tissue. Such false-positive findings comprise variants and pitfalls that can vary slightly in children as compared with adults. To determine the patterns and frequency of these potential false-positive findings on radioiodine scans in children with differentiated thyroid carcinoma. We reviewed a total of 223 radioiodine scans from 53 pediatric patients (mean age 13.3 years, 37 girls) with differentiated thyroid carcinoma. Focal or regional activity that likely did not represent functioning thyroid tissue or functioning thyroid carcinomatous tissue were categorized as variants or pitfalls. The final diagnosis was confirmed by reviewing the concurrent and follow-up clinical data, correlative ultrasonography, CT scanning, serum thyroglobulin and antithyroglobulin antibody levels. We calculated the frequency of these variants and pitfalls from diagnostic and post-therapy radioiodine scans. The most common variant on the radioiodine scans was the thymic activity (24/223, 10.8%) followed by the cardiac activity (8/223, 3.6%). Salivary contamination and star artifact, caused by prominent thyroid remnant, were the most important observed pitfalls. Variants and pitfalls that mimic functioning thyroid tissue or functioning thyroid carcinomatous tissue on radioiodine scan in children with differentiated thyroid carcinoma are not infrequent, but they decrease in frequency on successive radioiodine scans. Potential false-positive findings can be minimized with proper knowledge of the common variants and pitfalls in children and correlation with clinical, laboratory and imaging data. (orig.)

  6. Digitally generated excitation and near-baseband quadrature detection of rapid scan EPR signals.

    Science.gov (United States)

    Tseitlin, Mark; Yu, Zhelin; Quine, Richard W; Rinard, George A; Eaton, Sandra S; Eaton, Gareth R

    2014-12-01

    The use of multiple synchronized outputs from an arbitrary waveform generator (AWG) provides the opportunity to perform EPR experiments differently than by conventional EPR. We report a method for reconstructing the quadrature EPR spectrum from periodic signals that are generated with sinusoidal magnetic field modulation such as continuous wave (CW), multiharmonic, or rapid scan experiments. The signal is down-converted to an intermediate frequency (IF) that is less than the field scan or field modulation frequency and then digitized in a single channel. This method permits use of a high-pass analog filter before digitization to remove the strong non-EPR signal at the IF, that might otherwise overwhelm the digitizer. The IF is the difference between two synchronized X-band outputs from a Tektronix AWG 70002A, one of which is for excitation and the other is the reference for down-conversion. To permit signal averaging, timing was selected to give an exact integer number of full cycles for each frequency. In the experiments reported here the IF was 5kHz and the scan frequency was 40kHz. To produce sinusoidal rapid scans with a scan frequency eight times IF, a third synchronized output generated a square wave that was converted to a sine wave. The timing of the data acquisition with a Bruker SpecJet II was synchronized by an external clock signal from the AWG. The baseband quadrature signal in the frequency domain was reconstructed. This approach has the advantages that (i) the non-EPR response at the carrier frequency is eliminated, (ii) both real and imaginary EPR signals are reconstructed from a single physical channel to produce an ideal quadrature signal, and (iii) signal bandwidth does not increase relative to baseband detection. Spectra were obtained by deconvolution of the reconstructed signals for solid BDPA (1,3-bisdiphenylene-2-phenylallyl) in air, 0.2mM trityl OX63 in water, 15 N perdeuterated tempone, and a nitroxide with a 0.5G partially-resolved proton

  7. Fourier domain optical coherence tomography achieves full range complex imaging in vivo by introducing a carrier frequency during scanning

    International Nuclear Information System (INIS)

    Wang, Ruikang K

    2007-01-01

    The author describes a Fourier domain optical coherence tomography (FDOCT) system that is capable of full range complex imaging in vivo. This is achieved by introducing a constant carrier frequency into the OCT spectral interferograms at the time when imaging is performed. The complex functions of the spatial interferograms formed by each single wavelength are constructed before performing the Fourier transformation to localize the scatters within a sample. Two algorithms, based on Fourier filtering and Hilbert transformation, respectively, are described to achieve the full range complex FDOCT imaging. It is shown that the Hilbert transformation approach delivers better performance than the Fourier filtering method does in terms of tolerating the sample movement in vivo. The author finally demonstrates experimentally the system and algorithms for true in vivo imaging at a rate of 20 000 axial scans per second

  8. Atomized scan strategy for high definition for VR application

    Science.gov (United States)

    Huang, Shuping; Ran, Feng; Ji, Yuan; Chen, Wendong

    2017-10-01

    Silicon-based OLED (Organic Light Emitting Display) microdisplay technology begins to attract people's attention in the emerging VR and AR devices. The high display frame refresh rate is an important solution to alleviate the dizziness in VR applications. Traditional display circuit drivers use the analog method or the digital PWM method that follow the serial scan order from the first pixel to the last pixel by using the shift registers. This paper proposes a novel atomized scan strategy based on the digital fractal scan strategy using the pseudo-random scan order. It can be used to realize the high frame refresh rate with the moderate pixel clock frequency in the high definition OLED microdisplay. The linearity of the gray level is also improved compared with the Z fractal scan strategy.

  9. Automated surface-scanning detection of pathogenic bacteria on fresh produce

    Science.gov (United States)

    Horikawa, Shin; Du, Songtao; Liu, Yuzhe; Chen, I.-Hsuan; Xi, Jianguo; Crumpler, Michael S.; Sirois, Donald L.; Best, Steve R.; Wikle, Howard C.; Chin, Bryan A.

    2017-05-01

    This paper investigates the effects of surface-scanning detector position on the resonant frequency and signal amplitude of a wireless magnetoelastic (ME) biosensor for direct pathogen detection on solid surfaces. The experiments were conducted on the surface of a flat polyethylene (PE) plate as a model study. An ME biosensor (1 mm × 0.2 mm × 30 μm) was placed on the PE surface, and a surface-scanning detector was brought close and aligned to the sensor for wireless resonant frequency measurement. The position of the detector was accurately controlled by using a motorized three-axis translation system (i.e., controlled X, Y, and Z positions). The results showed that the resonant frequency variations of the sensor were -125 to +150 Hz for X and Y detector displacements of +/-600 μm and Z displacements of +100 to +500 μm. These resonant frequency variations were small compared to the sensor's initial resonant frequency (< 0.007% of 2.2 MHz initial resonant frequency) measured at the detector home position, indicating high accuracy of the measurement. In addition, the signal amplitude was, as anticipated, found to decrease exponentially with increasing detection distance (i.e., Z distance). Finally, additional experiments were conducted on the surface of cucumbers. Similar results were obtained.

  10. FR4-Based Electromagnetic Scanning Micromirror Integrated with Angle Sensor

    Directory of Open Access Journals (Sweden)

    Hongjie Lei

    2018-05-01

    Full Text Available This paper presents a flame retardant 4 (FR4-based electromagnetic scanning micromirror, which aims to overcome the limitations of conventional microelectromechanical systems (MEMS micromirrors for the large-aperture and low-frequency scanning applications. This micromirror is fabricated through a commercial printed circuit board (PCB technology at a low cost and with a short process cycle, before an aluminum-coated silicon mirror plate with a large aperture is bonded on the FR4 platform to provide a high surface quality. In particular, an electromagnetic angle sensor is integrated to monitor the motion of the micromirror in real time. A prototype has been assembled and tested. The results show that the micromirror can reach the optical scan angle of 11.2 ∘ with a low driving voltage of only 425 mV at resonance (361.8 Hz. At the same time, the signal of the integrated angle sensor also shows good signal-to-noise ratio, linearity and sensitivity. Finally, the reliability of the FR4 based micro-mirror has been tested. The prototype successfully passes both shock and vibration tests. Furthermore, the results of the long-term mechanical cycling test (50 million cycles suggest that the maximum variations of resonant frequency and scan angle are less than 0.3% and 6%, respectively. Therefore, this simple and robust micromirror has great potential in being useful in a number of optical microsystems, especially when large-aperture or low-frequency is required.

  11. Enhancing dynamic scanning force microscopy in air: as close as possible

    International Nuclear Information System (INIS)

    Palacios-Lidon, E; Perez-Garcia, B; Colchero, J

    2009-01-01

    Frequency modulation dynamic scanning force microscopy has been implemented in ambient conditions using low oscillation amplitudes (<1 nm) to simultaneously record not only topographic but also additional channels of information, in particular contact potential images. The performance of this mode as compared to the conventional amplitude modulation mode is analyzed in detail using a biological molecule, turning yellow mosaic virus RNA, as the model sample. On the basis of scanning force microscopy imaging as well as spectroscopy experiments, we find that for such very small samples the frequency modulation mode is superior since it can be operated with smaller tip-sample interaction, smaller effective tip-sample distance and lower forces. Combined with Kelvin probe microscopy it results not only in considerably higher electrostatic resolution, but also in correct quantitative values for the contact potential as compared to traditional amplitude modulation scanning force microscopy.

  12. Uninformative polymorphisms bias genome scans for signatures of selection

    Directory of Open Access Journals (Sweden)

    Roesti Marius

    2012-06-01

    Full Text Available Abstract Background With the establishment of high-throughput sequencing technologies and new methods for rapid and extensive single nucleotide (SNP discovery, marker-based genome scans in search of signatures of divergent selection between populations occupying ecologically distinct environments are becoming increasingly popular. Methods and Results On the basis of genome-wide SNP marker data generated by RAD sequencing of lake and stream stickleback populations, we show that the outcome of such studies can be systematically biased if markers with a low minor allele frequency are included in the analysis. The reason is that these ‘uninformative’ polymorphisms lack the adequate potential to capture signatures of drift and hitchhiking, the focal processes in ecological genome scans. Bias associated with uninformative polymorphisms is not eliminated by just avoiding technical artifacts in the data (PCR and sequencing errors, as a high proportion of SNPs with a low minor allele frequency is a general biological feature of natural populations. Conclusions We suggest that uninformative markers should be excluded from genome scans based on empirical criteria derived from careful inspection of the data, and that these criteria should be reported explicitly. Together, this should increase the quality and comparability of genome scans, and hence promote our understanding of the processes driving genomic differentiation.

  13. A novel solid-angle tomosynthesis (SAT) scanning scheme

    International Nuclear Information System (INIS)

    Zhang Jin; Yu, Cedric

    2010-01-01

    Purpose: Digital tomosynthesis (DTS) recently gained extensive research interests in both diagnostic and radiation therapy fields. Conventional DTS images are generated by scanning an x-ray source and flat-panel detector pair on opposite sides of an object, with the scanning trajectory on a one-dimensional curve. A novel tomosynthesis method named solid-angle tomosynthesis (SAT) is proposed, where the x-ray source scans on an arbitrary shaped two-dimensional surface. Methods: An iterative algorithm in the form of total variation regulated expectation maximization is developed for SAT image reconstruction. The feasibility and effectiveness of SAT is corroborated by computer simulation studies using three-dimensional (3D) numerical phantoms including a 3D Shepp-Logan phantom and a volumetric CT image set of a human breast. Results: SAT is able to cover more space in Fourier domain more uniformly than conventional DTS. Greater coverage and more isotropy in the frequency domain translate to fewer artifacts and more accurately restored features in the in-plane reconstruction. Conclusions: Comparing with conventional DTS, SAT allows cone-shaped x-ray beams to project from more solid angles, thus provides more coverage in the spatial-frequency domain, resulting in better quality of reconstructed image.

  14. Study on the high-frequency laser measurement of slot surface difference

    Science.gov (United States)

    Bing, Jia; Lv, Qiongying; Cao, Guohua

    2017-10-01

    In view of the measurement of the slot surface difference in the large-scale mechanical assembly process, Based on high frequency laser scanning technology and laser detection imaging principle, This paragraph designs a double galvanometer pulse laser scanning system. Laser probe scanning system architecture consists of three parts: laser ranging part, mechanical scanning part, data acquisition and processing part. The part of laser range uses high-frequency laser range finder to measure the distance information of the target shape and get a lot of point cloud data. Mechanical scanning part includes high-speed rotary table, high-speed transit and related structure design, in order to realize the whole system should be carried out in accordance with the design of scanning path on the target three-dimensional laser scanning. Data processing part mainly by FPGA hardware with LAbVIEW software to design a core, to process the point cloud data collected by the laser range finder at the high-speed and fitting calculation of point cloud data, to establish a three-dimensional model of the target, so laser scanning imaging is realized.

  15. Design of a high-speed electrochemical scanning tunneling microscope.

    Science.gov (United States)

    Yanson, Y I; Schenkel, F; Rost, M J

    2013-02-01

    In this paper, we present a bottom-up approach to designing and constructing a high-speed electrochemical scanning tunneling microscope (EC-STM). Using finite element analysis (FEA) calculations of the frequency response of the whole mechanical loop of the STM, we analyzed several geometries to find the most stable one that could facilitate fast scanning. To test the FEA results, we conducted measurements of the vibration amplitudes using a prototype STM setup. Based on the FEA analysis and the measurement results, we identified the potentially most disturbing vibration modes that could impair fast scanning. By modifying the design of some parts of the EC-STM, we reduced the amplitudes as well as increased the resonance frequencies of these modes. Additionally, we designed and constructed an electrochemical flow-cell that allows STM imaging in a flowing electrolyte, and built a bi-potentiostat to achieve electrochemical potential control during the measurements. Finally, we present STM images acquired during high-speed imaging in air as well as in an electrochemical environment using our newly-developed EC-STM.

  16. Bone scanning in the evaluation of lung cancer

    International Nuclear Information System (INIS)

    Jung, Kun Sik; Zeon, Seok Kil; Lee, Hee Jung; Song, Hong Suk

    1994-01-01

    We studied the diagnostic significance of bone scan in evaluation of bone metastasis by lung cancer, prevalence rate, and the causes of false positive bone scan and soft tissue accumulation of bone seeking agent. This subject include 73 lung cancer patients with bone scan, We analyzed the frequency of the metastasis, its distribution and configuration, and any relationship between bone pain and corresponding region on bone scan. The positive findings of bone scans were compared with simple X-ray film, CT, MRI and other diagnostic modalities. The false positive bone scan and the soft tissue accumulation of bone seeking agent were analyzed. The positive findings on bone scan were noted in 26 cases(36%) and they were coexistent with bone pain in 30%. The correspondence between bone scan and bone X-ray was 38%. False positive bone scans were seen in 12 cases(16%), which include fracture due to thoracotomy and trauma, degenerative bone disease, and bifid rib. Accumulation of bone seeking agent in soft tissue were seen in 13 cases(18%), which included primary tumor, enlarged cervical lymph node, pleural effusion, ascites and pleural thickening. Bone scans should be carefully interpreted in detecting bone metastasis in primary malignancy, because of the 16% false positivity and 18% soft tissue accumulation rate. It is very important to note that the correlation between bone pain and positive findings of bone scans was only 38%

  17. Bone scanning in the evaluation of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Kun Sik; Zeon, Seok Kil; Lee, Hee Jung; Song, Hong Suk [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-05-15

    We studied the diagnostic significance of bone scan in evaluation of bone metastasis by lung cancer, prevalence rate, and the causes of false positive bone scan and soft tissue accumulation of bone seeking agent. This subject include 73 lung cancer patients with bone scan, We analyzed the frequency of the metastasis, its distribution and configuration, and any relationship between bone pain and corresponding region on bone scan. The positive findings of bone scans were compared with simple X-ray film, CT, MRI and other diagnostic modalities. The false positive bone scan and the soft tissue accumulation of bone seeking agent were analyzed. The positive findings on bone scan were noted in 26 cases(36%) and they were coexistent with bone pain in 30%. The correspondence between bone scan and bone X-ray was 38%. False positive bone scans were seen in 12 cases(16%), which include fracture due to thoracotomy and trauma, degenerative bone disease, and bifid rib. Accumulation of bone seeking agent in soft tissue were seen in 13 cases(18%), which included primary tumor, enlarged cervical lymph node, pleural effusion, ascites and pleural thickening. Bone scans should be carefully interpreted in detecting bone metastasis in primary malignancy, because of the 16% false positivity and 18% soft tissue accumulation rate. It is very important to note that the correlation between bone pain and positive findings of bone scans was only 38%.

  18. Impulse excitation scanning acoustic microscopy for local quantification of Rayleigh surface wave velocity using B-scan analysis

    Science.gov (United States)

    Cherry, M.; Dierken, J.; Boehnlein, T.; Pilchak, A.; Sathish, S.; Grandhi, R.

    2018-01-01

    A new technique for performing quantitative scanning acoustic microscopy imaging of Rayleigh surface wave (RSW) velocity was developed based on b-scan processing. In this technique, the focused acoustic beam is moved through many defocus distances over the sample and excited with an impulse excitation, and advanced algorithms based on frequency filtering and the Hilbert transform are used to post-process the b-scans to estimate the Rayleigh surface wave velocity. The new method was used to estimate the RSW velocity on an optically flat E6 glass sample, and the velocity was measured at ±2 m/s and the scanning time per point was on the order of 1.0 s, which are both improvement from the previous two-point defocus method. The new method was also applied to the analysis of two titanium samples, and the velocity was estimated with very low standard deviation in certain large grains on the sample. A new behavior was observed with the b-scan analysis technique where the amplitude of the surface wave decayed dramatically on certain crystallographic orientations. The new technique was also compared with previous results, and the new technique has been found to be much more reliable and to have higher contrast than previously possible with impulse excitation.

  19. Admittance Scanning for Whole Column Detection.

    Science.gov (United States)

    Stamos, Brian N; Dasgupta, Purnendu K; Ohira, Shin-Ichi

    2017-07-05

    Whole column detection (WCD) is as old as chromatography itself. WCD requires an ability to interrogate column contents from the outside. Other than the obvious case of optical detection through a transparent column, admittance (often termed contactless conductance) measurements can also sense changes in the column contents (especially ionic content) from the outside without galvanic contact with the solution. We propose here electromechanically scanned admittance imaging and apply this to open tubular (OT) chromatography. The detector scans across the column; the length resolution depends on the scanning velocity and the data acquisition frequency, ultimately limited by the physical step resolution (40 μm in the present setup). Precision equal to this step resolution was observed for locating an interface between two immiscible liquids inside a 21 μm capillary. Mechanically, the maximum scanning speed was 100 mm/s, but at 1 kHz sampling rate and a time constant of 25 ms, the highest practical scan speed (no peak distortion) was 28 mm/s. At scanning speeds of 0, 4, and 28 mm/s, the S/N for 180 pL (zone length of 1.9 mm in a 11 μm i.d. column) of 500 μM KCl injected into water was 6450, 3850, and 1500, respectively. To facilitate constant and reproducible contact with the column regardless of minor variations in outer diameter, a double quadrupole electrode system was developed. Columns of significant length (>1 m) can be readily scanned. We demonstrate its applicability with both OT and commercial packed columns and explore uniformity of retention along a column, increasing S/N by stopped-flow repeat scans, etc. as unique applications.

  20. Scanning apparatus and method

    International Nuclear Information System (INIS)

    Brunnett, C.J.

    1980-01-01

    A novel method is described for processing the analogue signals from the photomultiplier tubes in a tomographic X-ray scanner. The system produces a series of pulses whose instantaneous frequency depends on the detected intensity of the X-radiation. A timer unit is used to determine the segment scan intervals and also to deduce the average radiation intensity detected during this interval. The overall system is claimed to possess the advantageous properties of low time delay, wide bandwidth and relative low cost. (U.K.)

  1. Resonant difference-frequency atomic force ultrasonic microscope

    Science.gov (United States)

    Cantrell, John H. (Inventor); Cantrell, Sean A. (Inventor)

    2010-01-01

    A scanning probe microscope and methodology called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create images of nanoscale near-surface and subsurface features.

  2. Retrieving the thermal diffusivity and effusivity of solids from the same frequency scan using the front photopyroelectric technique

    International Nuclear Information System (INIS)

    Salazar, Agustín; Oleaga, Alberto; Mendioroz, Arantza; Apiñaniz, Estibaliz

    2017-01-01

    The photopyroelectric (PPE) technique in the front configuration consists in illuminating one surface of a pyroelectric slab while the other surface is in contact with the test sample. This method has been widely used to measure the thermal effusivity of liquids. Recently, it has been extended to measure the thermal effusivity of solids, by taking into account the influence of the coupling fluid layer used to guarantee the thermal contact. In both cases, the sample (liquid or solid) must be very thick. In this work, we propose a classical frequency scan of a thin sample slab to retrieve the thermal diffusivity and effusivity simultaneously. We use the amplitude and the phase of the front PPE signal, which depend on four parameters: the sample diffusivity and effusivity, the coupling fluid thickness and the coefficient of heat losses. It is demonstrated that the four quantities are not correlated. PPE measurements performed on a set of calibrated solids confirm the ability of the method to obtain the thermal diffusivity and effusivity of solids accurately. (paper)

  3. "Slow-scanning" in Ground-based Mid-infrared Observations

    Science.gov (United States)

    Ohsawa, Ryou; Sako, Shigeyuki; Miyata, Takashi; Kamizuka, Takafumi; Okada, Kazushi; Mori, Kiyoshi; Uchiyama, Masahito S.; Yamaguchi, Junpei; Fujiyoshi, Takuya; Morii, Mikio; Ikeda, Shiro

    2018-04-01

    Chopping observations with a tip-tilt secondary mirror have conventionally been used in ground-based mid-infrared observations. However, it is not practical for next generation large telescopes to have a large tip-tilt mirror that moves at a frequency larger than a few hertz. We propose an alternative observing method, a "slow-scanning" observation. Images are continuously captured as movie data, while the field of view is slowly moved. The signal from an astronomical object is extracted from the movie data by a low-rank and sparse matrix decomposition. The performance of the "slow-scanning" observation was tested in an experimental observation with Subaru/COMICS. The quality of a resultant image in the "slow-scanning" observation was as good as in a conventional chopping observation with COMICS, at least for a bright point-source object. The observational efficiency in the "slow-scanning" observation was better than that in the chopping observation. The results suggest that the "slow-scanning" observation can be a competitive method for the Subaru telescope and be of potential interest to other ground-based facilities to avoid chopping.

  4. Effect of Solar Radiation on Viscoelastic Properties of Bovine Leather: Temperature and Frequency Scans

    Science.gov (United States)

    Nalyanya, Kallen Mulilo; Rop, Ronald K.; Onyuka, Arthur S.

    2017-04-01

    This work presents both analytical and experimental results of the effect of unfiltered natural solar radiation on the thermal and dynamic mechanical properties of Boran bovine leather at both pickling and tanning stages of preparation. Samples cut from both pickled and tanned pieces of leather of appropriate dimensions were exposed to unfiltered natural solar radiation for time intervals ranging from 0 h (non-irradiated) to 24 h. The temperature of the dynamic mechanical analyzer was equilibrated at 30°C and increased to 240°C at a heating rate of 5°C \\cdot Min^{-1}, while its oscillation frequency varied from 0.1 Hz to 100 Hz. With the help of thermal analysis (TA) control software which analyzes and generates parameter means/averages at temperature/frequency range, the graphs were created by Microsoft Excel 2013 from the means. The viscoelastic properties showed linear frequency dependence within 0.1 Hz to 30 Hz followed by negligible frequency dependence above 30 Hz. Storage modulus (E') and shear stress (σ ) increased with frequency, while loss modulus (E''), complex viscosity (η ^{*}) and dynamic shear viscosity (η) decreased linearly with frequency. The effect of solar radiation was evident as the properties increased initially from 0 h to 6 h of irradiation followed by a steady decline to a minimum at 18 h before a drastic increase to a maximum at 24 h. Hence, tanning industry can consider the time duration of 24 h for sun-drying of leather to enhance the mechanical properties and hence the quality of the leather. At frequencies higher than 30 Hz, the dynamic mechanical properties are independent of the frequency. The frequency of 30 Hz was observed to be a critical value in the behavior in the mechanical properties of bovine hide.

  5. Ultrasonic signal processing and B-SCAN imaging for nondestructive testing. Application to under - cladding - cracks

    International Nuclear Information System (INIS)

    Theron, G.

    1988-02-01

    Crack propagation under the stainless steel cladding of nuclear reactor vessels is monitored by ultrasonic testing. This work study signal processing to improve detection and sizing of defects. Two possibilities are examined: processing of each individual signal and simultaneous processing of all the signals giving a B-SCAN image. The bibliographic study of time-frequency methods shows that they are not suitable for pulses. Then decomposition in instantaneous frequency and envelope is used. Effect of interference of 2 close echoes on instantaneous frequency is studies. The deconvolution of B-SCAN images is obtained by the transducer field. A point-by-point deconvolution method, less noise sensitive, is developed. B-SCAN images are processed in 2 phases: interface signal processing and deconvolution. These calculations improve image accuracy and dynamics. Water-stell interface and ferritic-austenitic interface are separated. Echoes of crack top are visualized and crack-hole differentiation is improved [fr

  6. Scanning Ultrasonic Spectroscopy System Developed for the Inspection of Composite Flywheels

    Science.gov (United States)

    Martin, Richard E.; Baaklini, George Y.

    2002-01-01

    Composite flywheels are being considered as replacements for chemical batteries aboard the International Space Station. A flywheel stores energy in a spinning mass that can turn a generator to meet power demands. Because of the high rotational speeds of the spinning mass, extensive testing of the flywheel system must be performed prior to flight certification. With this goal in mind, a new scanning system has been developed at the NASA Glenn Research Center for the nondestructive inspection of composite flywheels and flywheel subcomponents. The system uses ultrasonic waves to excite a material and examines the response to detect and locate flaws and material variations. The ultrasonic spectroscopy system uses a transducer to send swept-frequency ultrasonic waves into a test material and then receives the returning signal with a second transducer. The received signal is then analyzed in the frequency domain using a fast Fourier transform. A second fast Fourier transform is performed to examine the spacing of the peaks in the frequency domain. The spacing of the peaks is related to the standing wave resonances that are present in the material because of the constructive and destructive interferences of the waves in the full material thickness as well as in individual layers within the material. Material variations and flaws are then identified by changes in the amplitudes and positions of the peaks in both the frequency and resonance spacing domains. This work, conducted under a grant through the Cleveland State University, extends the capabilities of an existing point-by-point ultrasonic spectroscopy system, thus allowing full-field automated inspection. Results of an ultrasonic spectroscopy scan of a plastic cylinder with intentionally seeded flaws. The result of an ultrasonic spectroscopy scan of a plastic cylinder used as a proof-of-concept specimen is shown. The cylinder contains a number of flat bottomed holes of various sizes and shapes. The scanning system

  7. Modeling of MOEMS electromagnetic scanning grating mirror for NIR micro-spectrometer

    Directory of Open Access Journals (Sweden)

    Ying Zhou

    2016-02-01

    Full Text Available In this paper, the mathematical model is developed for researching the detailed electromagnetic mechanism of MOEMS scanning mirror. We present the relationship between spectral range and optical scanning angle. Furthermore, the variation tendencies of resonant frequency and maximal torsional angle are studied in detail under different aspect ratios of MOEMS scanning mirror and varied dimensions of torsional bar. The numerical results and Finite Element Analysis simulations both indicate that the thickness of torsional bar is the most important factor. The maximal torsional angle appears when the aspect ratio equals to 1. This mathematical model is an effective way for designing the MOEMS electromagnetic scanning grating mirror in actual fabrication.

  8. Quantitative analysis of tip-sample interaction in non-contact scanning force spectroscopy

    International Nuclear Information System (INIS)

    Palacios-Lidon, Elisa; Colchero, Jaime

    2006-01-01

    Quantitative characterization of tip-sample interaction in scanning force microscopy is fundamental for optimum image acquisition as well as data interpretation. In this work we discuss how to characterize the electrostatic and van der Waals contribution to tip-sample interaction in non-contact scanning force microscopy precisely. The spectroscopic technique presented is based on the simultaneous measurement of cantilever deflection, oscillation amplitude and frequency shift as a function of tip-sample voltage and tip-sample distance as well as on advanced data processing. Data are acquired at a fixed lateral position as interaction images, with the bias voltage as fast scan, and tip-sample distance as slow scan. Due to the quadratic dependence of the electrostatic interaction with tip-sample voltage the van der Waals force can be separated from the electrostatic force. Using appropriate data processing, the van der Waals interaction, the capacitance and the contact potential can be determined as a function of tip-sample distance. The measurement of resonance frequency shift yields very high signal to noise ratio and the absolute calibration of the measured quantities, while the acquisition of cantilever deflection allows the determination of the tip-sample distance

  9. Insights into glass transition and relaxation behavior using temperature-modulated differential scanning calorimetry

    DEFF Research Database (Denmark)

    Guo, Xiaoju; Mauro, J.C.; Allan, D.C.

    Temperature-modulated differential scanning calorimetry (TMDSC) is based on conventional DSC but with a sinusoidally modulated temperature path. Our simulations of TMDSC signals prove that the frequency correction of non-reversing heat flow can give a master curve within a certain range...... of frequencies. This frequency range is dependent not only on the measurement parameters such as linear heating/cooling rate and frequency and amplitude of the modulation, but also on the previous thermal history before the TMDSC measurement. The frequency correction for the reversing heat flow gives more...

  10. Fast-scan NMR imaging

    International Nuclear Information System (INIS)

    Iwaoka, Hideto; Matsuura, Hiroyuki; Sugiyama, Tadashi; Hirata, Takaaki

    1987-01-01

    This paper describes the Fast Recovery (FR) method for fast-scan Nuclear Magnetic Resonance imaging. The FR method uses a sequence of four radio frequency pulses - alternating selective 90 deg nutation pulses and nonselective 180 deg pulses. One free induction decay (FID) signal and one echo signal are detected and averaged to compute a 2-D image. In the modified FR method, extra 180 deg pulses are applied between 90 deg pulses to cause refocusing and the resultant spin echo signals are averaged to improve the signal to noise ratio. For the FR and modified FR sequences, the macroscopic magnetization is restored to equilibrium quickly and exactly; scan time can consequently be less than that for conventional pulse sequences, such as used in the saturation recovery method, without any penalty in signal to noise ratio. This paper derives expressions for the signal to noise ratio, scan time ratio and contrast noise ratio, compares the FR and modified FR methods with the saturation recovery method and presents experimental results for human body images. In theory and practice, the signal to noise ratio for the FR method is larger than that for the modified FR method. For a given signal to noise ratio the scan time is between one half and one fourth that for the saturation recovery method. The optimum repetition period, T r , is 0.07 ∼ 0.25 s for the FR method, and 0.1 ∼ 0.5 s for the modified FR method. Contrast noise ratio is low for high speed imaging, T r = 0.07 ∼ 0.25 s, but, high contrast noise ratio image is obtained for T r > 0.5 s. (author)

  11. Seismic scanning tunneling macroscope - Theory

    KAUST Repository

    Schuster, Gerard T.

    2012-09-01

    We propose a seismic scanning tunneling macroscope (SSTM) that can detect the presence of sub-wavelength scatterers in the near-field of either the source or the receivers. Analytic formulas for the time reverse mirror (TRM) profile associated with a single scatterer model show that the spatial resolution limit to be, unlike the Abbe limit of λ/2, independent of wavelength and linearly proportional to the source-scatterer separation as long as the point scatterer is in the near-field region; if the sub-wavelength scatterer is a spherical impedance discontinuity then the resolution will also be limited by the radius of the sphere. Therefore, superresolution imaging can be achieved as the scatterer approaches the source. This is analogous to an optical scanning tunneling microscope that has sub-wavelength resolution. Scaled to seismic frequencies, it is theoretically possible to extract 100 Hz information from 20 Hz data by imaging of near-field seismic energy.

  12. Seismic scanning tunneling macroscope - Theory

    KAUST Repository

    Schuster, Gerard T.; Hanafy, Sherif M.; Huang, Yunsong

    2012-01-01

    We propose a seismic scanning tunneling macroscope (SSTM) that can detect the presence of sub-wavelength scatterers in the near-field of either the source or the receivers. Analytic formulas for the time reverse mirror (TRM) profile associated with a single scatterer model show that the spatial resolution limit to be, unlike the Abbe limit of λ/2, independent of wavelength and linearly proportional to the source-scatterer separation as long as the point scatterer is in the near-field region; if the sub-wavelength scatterer is a spherical impedance discontinuity then the resolution will also be limited by the radius of the sphere. Therefore, superresolution imaging can be achieved as the scatterer approaches the source. This is analogous to an optical scanning tunneling microscope that has sub-wavelength resolution. Scaled to seismic frequencies, it is theoretically possible to extract 100 Hz information from 20 Hz data by imaging of near-field seismic energy.

  13. Scanning tip measurement for identification of point defects

    Directory of Open Access Journals (Sweden)

    Raineri Vito

    2011-01-01

    Full Text Available Abstract Self-assembled iron-silicide nanostructures were prepared by reactive deposition epitaxy of Fe onto silicon. Capacitance-voltage, current-voltage, and deep level transient spectroscopy (DLTS were used to measure the electrical properties of Au/silicon Schottky junctions. Spreading resistance and scanning probe capacitance microscopy (SCM were applied to measure local electrical properties. Using a preamplifier the sensitivity of DLTS was increased satisfactorily to measure transients of the scanning tip semiconductor junction. In the Fe-deposited area, Fe-related defects dominate the surface layer in about 0.5 μm depth. These defects deteriorated the Schottky junction characteristic. Outside the Fe-deposited area, Fe-related defect concentration was identified in a thin layer near the surface. The defect transients in this area were measured both in macroscopic Schottky junctions and by scanning tip DLTS and were detected by bias modulation frequency dependence in SCM.

  14. Effect of mid-scan breathing changes on quality of 4DCT using a commercial phase-based sorting algorithm.

    Science.gov (United States)

    Noel, Camille E; Parikh, Parag J

    2011-05-01

    Though it is known that irregular breathing can introduce artifacts in commercial 4DCT, this has not been systematically explored. The purpose of this study is to investigate the effect of variations in basic parameters of the breathing wave on 4DCT imaging quality. A four-dimensional motion platform holding an acrylic sphere was scanned while moving in a trajectory modeled from a lung cancer patient. A bellows device was used as a respiratory surrogate, and the images were sorted by a commercial phase-based sorting algorithm. Motion during the first half of the scan was produced at a baseline trajectory with a consistent frequency and amplitude of 15 breaths per minute and 1 cm, peak to peak. The two parameters were then varied mid-scan to new frequency and amplitude values, with frequencies ranging from 7.5 to 22 bpm and amplitudes ranging from 0.5 to 1.5 cm. Image sets representing four respiratory phases were contoured. Each set was analyzed to compare centroid displacement, density homogeneity, and volumetric and geometric distortions of the imaged sphere. Undercoverage of the target ITV and overcoverage of healthy tissue was also evaluated. Changes in amplitude of 25% or more, with or without changes in frequency, consistently caused measurable distortions in shape, position, and density of the imaged sphere. Frequency changes over 50% showed a similar trend. This study suggests that basic breathing statistics can be used to quickly assess the quality of a 4DCT scan prior to image reconstruction. Such information can help give indication of the proper course of action when irregular breathing patterns are observed during CT scanning.

  15. Real-time dynamic calibration of a tunable frequency laser source using a Fabry-Pérot interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Mandula, Gábor, E-mail: mandula.gabor@wigner.mta.hu; Kis, Zsolt; Lengyel, Krisztián [Wigner Research Centre for Physics of the Hungarian Academy of Sciences, Konkoly-Thege Miklós út 29-33, H-1121 Budapest (Hungary)

    2015-12-15

    We report on a method for real-time dynamic calibration of a tunable external cavity diode laser by using a partially mode-matched plano-concave Fabry-Pérot interferometer in reflection geometry. Wide range laser frequency scanning is carried out by piezo-driven tilting of a diffractive grating playing the role of a frequency selective mirror in the laser cavity. The grating tilting system has a considerable mechanical inertness, so static laser frequency calibration leads to false results. The proposed real-time dynamic calibration based on the identification of primary- and Gouy-effect type secondary interference peaks with known frequency and temporal history can be used for a wide scanning range (from 0.2 GHz to more than 1 GHz). A concave spherical mirror with a radius of R = 100 cm and a plain 1% transmitting mirror was used as a Fabry-Pérot interferometer with various resonator lengths to investigate and demonstrate real-time calibration procedures for two kinds of laser frequency scanning functions.

  16. Frequency characteristics of the laser film digitizer

    International Nuclear Information System (INIS)

    Ishimitsu, Y.; Taira, R.K.; Huang, H.K.

    1988-01-01

    The frequency characteristics of the laser film digitizer in the parallel and in the perpendicular scan direction are different. Because of this difference, moire pattern artifacts may appear in the digitized image. The authors found that this phenomenon is due to the frequency transfer characteristics of the various components in the laser film digitizer. From this observation, they derive a relationship between the spatial frequency content of the original image and the laser beam spot size based on the concept of image contrast. This relationship can be utilized to avoid the appearance of the moire pattern in the digitized image

  17. Frequency comb calibrated frequency-sweeping interferometry for absolute group refractive index measurement of air.

    Science.gov (United States)

    Yang, Lijun; Wu, Xuejian; Wei, Haoyun; Li, Yan

    2017-04-10

    The absolute group refractive index of air at 194061.02 GHz is measured in real time using frequency-sweeping interferometry calibrated by an optical frequency comb. The group refractive index of air is calculated from the calibration peaks of the laser frequency variation and the interference signal of the two beams passing through the inner and outer regions of a vacuum cell when the frequency of a tunable external cavity diode laser is scanned. We continuously measure the refractive index of air for 2 h, which shows that the difference between measured results and Ciddor's equation is less than 9.6×10-8, and the standard deviation of that difference is 5.9×10-8. The relative uncertainty of the measured refractive index of air is estimated to be 8.6×10-8. The data update rate is 0.2 Hz, making it applicable under conditions in which air refractive index fluctuates fast.

  18. Validation of multi-channel scanning microwave radiometer on-board Oceansat-1

    Digital Repository Service at National Institute of Oceanography (India)

    Muraleedharan, P.M.; Pankajakshan, T.; Harikrishnan, M.

    Sea surface temperature (SST), sea surface wind speed (WS) and columnar water vapour (WV) derived from Multi-frequency Scanning Microwave Radiometer (MSMR) sensor on-board IRS-P4 (Oceansat-1) were validated against the in situ measurements from ship...

  19. Frequent Computed Tomography Scanning Due to Incomplete Three-View X-Ray Imaging of the Cervical Spine

    NARCIS (Netherlands)

    Saltzherr, Teun Peter; Beenen, Ludo F. M.; Reitsma, Johannes B.; Luitse, Jan S. K.; Vandertop, W. Peter; Goslings, J. Carel

    2010-01-01

    Background: Conventional C-spine imaging (3-view series) is still widely used in trauma patients, although the utilization of computed tomography (CT) scanning is increasing. The aim of this study was to analyze the value of conventional radiography and the frequency of subsequent CT scanning due to

  20. Analysis of the Structure of Vertical Combdrives of Fast Scanning Micromirrors

    Science.gov (United States)

    Wada, Hiroyuki

    2004-04-01

    The advantages of the fast scanning micromirror above vertical combdrives (bottom type) fabricated by the self-alignment process are reported. The fill factor of the bottom type was larger than that of a fast scanning micromirror beside vertical combdrives (side type) fabricated previously. The maximum tilt angle of the bottom type was larger than that of the side type. The probability of the failure mode at applied high voltage and the narrow gap between the upper and lower comb teeth (snap down) of the bottom type was lower than that of the side type. A bottom-type fast scanning micromirror the resonant frequency of which was 50.8 kHz was fabricated.

  1. Photothermal Investigation of Micro-Uniformity Problems Caused by Different Scan Systems

    International Nuclear Information System (INIS)

    Geiler, Hans; Brand, Klaus; Selle, Hans-Joachim

    2008-01-01

    To study beam scanning and beam profiling effects low energy implants of Boron (25 keV) and high energy implants of Helium (5.4 MeV) were carried out by use of different scanning systems including mechanical, electrostatic and hybrid scanning. The sensitivity of photothermal measurement by use of the excess carrier wave in the depth up to 50 μm is proved for buried damage detection and compared with the effect in shallow damage profiles. The micro-mapping capability of the photothermal techniques allows the detection of dose variations in a sub-mm-scale without Moire effects from mapping steps. Conclusion for advanced dose monitoring by multi-frequency photothermal methods will be derived.

  2. Information Source Characteristics and Environmental Scanning by Academic Library Managers

    Science.gov (United States)

    Babalhavaeji, Fahimeh; Farhadpoor, Mohammad Reza

    2013-01-01

    Purpose: This article examines characteristics of the external environment of library and information centres of Islamic Azad University in Iran, focusing on perceived environmental uncertainty and perceived source accessibility and quality, and their impacts on the amount of scanning and the frequency of information source use. Methods: This…

  3. PRF Ambiguity Detrmination for Radarsat ScanSAR System

    Science.gov (United States)

    Jin, Michael Y.

    1998-01-01

    PRF ambiguity is a potential problem for a spaceborne SAR operated at high frequencies. For a strip mode SAR, there were several approaches to solve this problem. This paper, however, addresses PRF ambiguity determination algorithms suitable for a burst mode SAR system such as the Radarsat ScanSAR. The candidate algorithms include the wavelength diversity algorithm, range look cross correlation algorithm, and multi-PRF algorithm.

  4. Incidental findings on MRI scans of patients presenting with audiovestibular symptoms.

    Science.gov (United States)

    Papanikolaou, Vasileios; Khan, Mohammad H; Keogh, Ivan J

    2010-06-07

    The evaluation of patients presenting with audiovestibular symptoms usually includes MRI of the internal auditory meatus, the cerebellopontine angle and the brain. A significant percentage of these scans will present unexpected, incidental findings, which could have important clinical significance. To determine the frequency and clinical significance of incidental findings on MRI scans of patients with audiovestibular symptoms. A retrospective analysis of 200 serial MRI scans. Gender distribution: equal. Age range: 17-82 years. One-hundred and four scans (52%) were normal and 1 scan (0.5%) demonstrated a unilateral vestibular schwannoma. Ninety-five scans (47.5%) demonstrated incidental findings. Sixty-six of these (33%) were considered of ishaemic origin and did not require further action. Five (2.5%) scans demonstrated significant findings which warranted appropriate referral; Two Gliomas (1%), 2 cases of extensive White Matter Lesions (1%), 1 lipoma (0.5%). The remaining scans demonstrated various other findings. Investigation of patients with audiovestibular symptoms with MRI scans revealed incidental findings in a significant percentage (47.5%). The majority of these findings were benign warranting no further action and only 2.5% required further referral. It is the responsibility of the referring Otolaryngologist to be aware of these findings, to be able to assess their significance, to inform the patient and if needed to refer for further evaluation.

  5. Prognostic value of the acute DMSA scan in hospitalized children with urinary tract infection

    Directory of Open Access Journals (Sweden)

    Hashemian H

    2008-12-01

    Full Text Available "nBackground: Urinary Tract Infection (UTI is one of the major etiological factors of permanent kidney impairment, resulting in renal scarring and severe and pernicious side effects, such as arterial hypertension and renal failure. The purpose of this study was to clarify the impression of renal parenchyma involvement by first UTI (on the basis of acute DMSA scan and vesicoureteral reflux (VUR-on the basis of VCUG/ RNC on the renal scar formation (on the basis of late DMSA scan. "nMethods: Children diagnosed with their first UTI at the Children's Hospital Medical Center, Tehran, Iran, were evaluated. For each patient, we recorded age, sex, results of VCUG/RNCs and acute DMSA scan, as well as those of a late DMSA scan performed 4-6 months later. The results of acute and late DMSA scans were compared along with the results of VCUG/RNCs. "nResults: This study included a total of 103 children, of whom 16 (15.5% were boys and 87 (84.5% were girls. The mean age was 27.2±27.7 months. The frequency of renal scars in kidneys with mild (28.6%, 8.7% and moderate (33.3%, 18.2% pyelonephritis with or without VUR was not significantly different, while the frequency of renal scars in kidneys with severe pyelonephritis (84.6%, 23.1% in the presence of VUR was significantly higher than non-refluxing kidneys with severe pyelonephritis (p=0.005. Furthermore, the frequency of renal scars in refluxing kidneys increased significantly with the severity of pyelonephritis (normal 8.3%, mild 28.6%, moderate 33.3%, and severe 84.6%; p=0.001. This pattern was not significant in non-refluxing kidneys (0%, 10.3%, 18.2%, and 23.1%, respectively; p=0.062. "nConclusion: The present study indicates that the incidence of renal scarring increases with pyelonephritis severity in patients with VUR. Furthermore, we can estimate the risk of renal scar formation from the results of acute DMSA scan and VCUG/RNC.

  6. A multi-axis electrothermal micromirror for a miniaturized OCT system

    KAUST Repository

    Izhar, U.

    2011-06-01

    We report on the development of a low power thermally actuated bi-axis SOI micromirror that is capable of performing angular and vertical scans for optical coherence tomography (OCT) applications. The device consists of a mirror with an aluminum coating over a 3 μm thick single crystal silicon base, aluminum/polysilicon electrothermal actuators with embedded heaters and polysilicon flexural connectors. In scanning mode, this mirror can satisfy our target specification of 5° angle at the low power of 1.7 mW with a temperature increase of 16.5 °C ± 7 °C from ambient in the actuator. Furthermore, a maximum angle of 32° has been achieved at 12 mW. In piston mode, it can reach vertical displacements of up to 131 μm at 12 mW with the temperature increase of 16.5 °C ± 7 °C from ambient in the actuator. The scanning speed for the mirror has been measured and the time response of the mirror is found to be 100 ms. The curvature of the mirror is found to be 2.4 mm ± 0.26 mm with a roughness of 100 nm ± 20 nm. Due to low driving power and moderate temperatures developed during its operation, this device can potentially be integrated with broadband light source, photodetector and interferometery system, to form a fully integrated OCT system on GaAs substrate. © 2011 Elsevier B.V. All rights reserved.

  7. The DMSA scan in paediatric urinary tract infection

    International Nuclear Information System (INIS)

    Ditchfield, M.R.; Nadel, H.R.

    1998-01-01

    The objective of the present paper was to review the use of the dimercaptosuccinic acid (DMSA) scan in urinary tract infection at British Columbia's Children's Hospital to determine the frequency of cortical defects and the association between vesico-ureteric reflux and the presence of cortical defects in children with urinary tract infection. A total of 129 consecutive children with a urinary tract infection referred for a DMSA scan in a 2-year period (January 1992-January 1994) were retrospectively studied. The results were analysed in terms of kidneys, and the incidence of cortical defects was determined. Eighty-eight patients (68%) had a radiographic micturating cysto-urethrogram within 6 months of the DMSA scan, and in this group the relationship of defects with vesico-ureteric reflux was determined. Overall, 81/258 (31%) of kidneys had a cortical defect on a DMSA scan. Of those who had a micturating cysto-urethrogram, 53/176 (30%) kidneys had vesico-ureteric reflux, and of those that had reflux, 21/53 (40%) had a cortical defect on a DMSA scan. In the group of children without reflux, 38/123 (31%) had a cortical defect. Renal cortical scan defects are common findings in paediatric urinary infection, and frequently occur in the absence of vesico-ureteric reflux. These defects represent either established scars or acute pyelonephritis that can proceed to scarring. The micturating cysto-urethro-gram alone is insufficient as a screening modality to identify those kidneys at risk of renal scarring. Copyright (1998) Blackwell Science Pty Ltd

  8. Scanning fluorescent microscopy is an alternative for quantitative fluorescent cell analysis.

    Science.gov (United States)

    Varga, Viktor Sebestyén; Bocsi, József; Sipos, Ferenc; Csendes, Gábor; Tulassay, Zsolt; Molnár, Béla

    2004-07-01

    Fluorescent measurements on cells are performed today with FCM and laser scanning cytometry. The scientific community dealing with quantitative cell analysis would benefit from the development of a new digital multichannel and virtual microscopy based scanning fluorescent microscopy technology and from its evaluation on routine standardized fluorescent beads and clinical specimens. We applied a commercial motorized fluorescent microscope system. The scanning was done at 20 x (0.5 NA) magnification, on three channels (Rhodamine, FITC, Hoechst). The SFM (scanning fluorescent microscopy) software included the following features: scanning area, exposure time, and channel definition, autofocused scanning, densitometric and morphometric cellular feature determination, gating on scatterplots and frequency histograms, and preparation of galleries of the gated cells. For the calibration and standardization Immuno-Brite beads were used. With application of shading compensation, the CV of fluorescence of the beads decreased from 24.3% to 3.9%. Standard JPEG image compression until 1:150 resulted in no significant change. The change of focus influenced the CV significantly only after +/-5 microm error. SFM is a valuable method for the evaluation of fluorescently labeled cells. Copyright 2004 Wiley-Liss, Inc.

  9. Relative Frequency of Maxillofacial Fracture in CT-Scan Radiographs in Shahid Sadoghi and Shahid Rahnemoun Emergency Departments in Yazd from 2007 Till 2010

    Directory of Open Access Journals (Sweden)

    Ezoddini Ardakan

    2012-02-01

    Full Text Available Introduction: Technologic improvement and increased production of car and motorcycle have led to the increased incidence of maxillofacial trauma all around the world. Injuries of maxillofacial region include fractures of mandible, maxilla, zygoma, orbit and nasal bone, which is due to different etiologic factors such as motor vehicle accidents, quarreling, fall, and sport-related and work- related accidents. The Purpose of this study was to evaluate the frequency of maxillofacial fracture in CT-scan radiographs in Shahid Sadoghi and Shahid Rahnemon emergency departments in Yazd from 2007 till 2010. Methods: In this retrospective study we assessed the medical files of all patients with maxillofacial traumawho were admitted at Shahid Sadoughi and Shahid Rahnemoun hospitals in ENT and surgery wards during a 4-year period. The information from patients' medical file and CT scan radiographs were recorded. At last 372 patients were evaluated. Results: In this study the age of patients showed to be between 20 and 29. Eighty six and fourteen percent of patients were males and females, respectively. Among all fractures, mandible fracture was the most frequent one (50.8%. The most frequent etiologic factor was accident (59% and the most frequent outcome was partial recovery (46.4% and death was observed in 0.8% of individuals. Conclusion: Results of this study showed that the most frequent etiologic factor of trauma to maxillofacial region is motor vehicle accident similar to other developing countries.

  10. Simulation-aided design and fabrication of nanoprobes for scanning probe microscopy

    International Nuclear Information System (INIS)

    Liu, Bernard Haochih; Chang, Day-Bin

    2011-01-01

    We proposed and demonstrated a flexible and effective method to design and fabricate scanning probes for atomic force microscopy applications. Computer simulations were adopted to evaluate design specifications and desired performance of atomic force microscope (AFM) probes; the fabrication processes were guided by feedback from simulation results. Through design-simulation-fabrication iterations, tipless cantilevers and tapping mode probes were successfully made with errors as low as 2% in designed resonant frequencies. For tapping mode probes, the probe tip apex achieved a 10 nm radius of curvature without additional sharpening steps; tilt-compensated probes were also fabricated for better scanning performance. This method provides AFM users improved probe quality and practical guidelines for customized probes, which can support the development of novel scanning probe microscopy (SPM) applications. -- Research highlights: → We developed a design-simulation-fabrication strategy for customized AFM/SPM probes and demonstrated the results of tipless cantilever, sharpened probe tip, and tilt-compensated probe. → This simulation-aided method improved the geometry control and performance prediction of AFM probes; the error in resonant frequency was reduced to ∼2%. → Integration of simulation in design and fabrication of AFM probes expedites development of new probes and consequently promotes novel SPM applications.

  11. Clinical Significance of Diffuse Intrathoracic Uptake on Post-Therapy I-131 Scans in Thyroid Cancer Patients

    International Nuclear Information System (INIS)

    Choi, Hyun Su; Kim, Sung Hoon; Park, Sonya Youngju; Park, Hye Lim; Seo, Ye Young; Choi, Woo Hee

    2014-01-01

    The purpose of this study was to identify the frequency and possible cause of diffuse intrathoracic uptake on post-therapy I-131 scans in thyroid cancer patients. We retrospectively reviewed 781 post-therapy scans of 755 thyroid cancer patients who underwent total thyroidectomy and radioactive iodine therapy between January and December 2010. Diffuse intrathoracic uptake on post-therapy scans was examined, and clinical patient characteristics including sex, age, regimen for thyroid-stimulating hormone (TSH) stimulation (thyroid hormone withdrawal or recombinant human TSH injection), TSH, thyroglobulin (Tg) and anti-thyroglobulin antibody (anti-Tg Ab) levels, therapeutic dose of radioactive iodine therapy and prior history of radioactive iodine therapy were recorded.Scan findings were correlated with chest CT, chest radiographs, laboratory tests and/or clinical status. Diffuse intrathoracic uptake without evidence of pathologic condition was categorized as indeterminate. The association between clinical characteristics and intrathoracic uptake were analyzed for negative intrathoracic uptake and indeterminate uptake groups. Diffuse intrathoracic uptake on post-therapy scans was demonstrated in 39 out of 755 (5.2 %) patients, among which 3 were confirmed as lung metastasis. The 14 patients that showed high Tg or anti-Tg Ab levels were considered to be at risk of having undetected micrometastasis on other imaging modalities. The remaining 22 were indeterminate (2.9 %). Upon comparison of negative intrathoracic uptake and indeterminate uptake groups, TSH stimulation by thyroid hormone withdrawal was shown to be significantly correlated with diffuse intrathoracic uptake (p <0.05). The frequency of diffuse intrathoracic uptake on post-therapy scans was 5.2 % and could be seen in thyroid cancer patients with underlying lung metastasis as well as those without definite pathologic condition. In the latter, there was a higher frequency for diffusely increased intrathoracic

  12. Aortic valve calcification - a commonly observed but frequently ignored finding during CT scanning of the chest.

    Science.gov (United States)

    Raju, Prashanth; Sallomi, David; George, Bindu; Patel, Hitesh; Patel, Nikhil; Lloyd, Guy

    2012-06-01

    To describe the frequency and severity of Aortic valve calcification (AVC) in an unselected cohort of patients undergoing chest CT scanning and to assess the frequency with which AVC was being reported in the radiology reports. Consecutive CT scan images of the chest and the radiological reports (December 2009 to May 2010) were reviewed at the district general hospital (DGH). AVC on CT scan was visually graded on a scale ranging from 0 to IV (0 = no calcification, IV = severe calcification). Total of 416 (232 male; 184 female) CT chest scans [Contrast enhanced 302 (72%), unenhanced 114 (28%)] were reviewed. Mean age was 70.55 ± 11.48 years. AVC in CT scans was identified in 95 of the 416 patients (22.83%). AVC classification was as follows: Grade I: 60 (63.15%), Grade II: 22 (23.15%), Grade III: 9 (9.47%), Grade IV: 4 (4.21%). Only one CT report mentioned AVC. Only 31 of 95 AVC had Transthoracic echocardiogram (TTE). The interval time between CT scan and TTE was variable.   Aortic valve calcification in CT chest scans is a common finding and studies have shown that it is strongly related to the presence and severity of aortic valve disease. As CT scans are considered as a valuable additional screening tool for detection of aortic stenosis, AVC should always be commented upon in the radiology reports. Furthermore, patients with at least Grade III and IV AVC should be sent for TTE. © 2012 Blackwell Publishing Ltd.

  13. A simplified digital lock-in amplifier for the scanning grating spectrometer.

    Science.gov (United States)

    Wang, Jingru; Wang, Zhihong; Ji, Xufei; Liu, Jie; Liu, Guangda

    2017-02-01

    For the common measurement and control system of a scanning grating spectrometer, the use of an analog lock-in amplifier requires complex circuitry and sophisticated debugging, whereas the use of a digital lock-in amplifier places a high demand on the calculation capability and storage space. In this paper, a simplified digital lock-in amplifier based on averaging the absolute values within a complete period is presented and applied to a scanning grating spectrometer. The simplified digital lock-in amplifier was implemented on a low-cost microcontroller without multipliers, and got rid of the reference signal and specific configuration of the sampling frequency. Two positive zero-crossing detections were used to lock the phase of the measured signal. However, measurement method errors were introduced by the following factors: frequency fluctuation, sampling interval, and integer restriction of the sampling number. The theoretical calculation and experimental results of the signal-to-noise ratio of the proposed measurement method were 2055 and 2403, respectively.

  14. High-resolution mid-IR spectrometer based on frequency upconversion

    DEFF Research Database (Denmark)

    Hu, Qi; Dam, Jeppe Seidelin; Pedersen, Christian

    2012-01-01

    We demonstrate a novel approach for high-resolution spectroscopy based on frequency upconversion and postfiltering by means of a scanning Fabryx2013;Perot interferometer. The system is based on sum-frequency mixing, shifting the spectral content from the mid-infrared to the near-visible region al......-frequency 1064xA0;nm laser. We investigate water vapor emission lines from a butane burner and compare the measured results to model data. The presented method we suggest to be used for real-time monitoring of specific gas lines and reference signals....

  15. Scanning microwave microscopy applied to semiconducting GaAs structures

    Science.gov (United States)

    Buchter, Arne; Hoffmann, Johannes; Delvallée, Alexandra; Brinciotti, Enrico; Hapiuk, Dimitri; Licitra, Christophe; Louarn, Kevin; Arnoult, Alexandre; Almuneau, Guilhem; Piquemal, François; Zeier, Markus; Kienberger, Ferry

    2018-02-01

    A calibration algorithm based on one-port vector network analyzer (VNA) calibration for scanning microwave microscopes (SMMs) is presented and used to extract quantitative carrier densities from a semiconducting n-doped GaAs multilayer sample. This robust and versatile algorithm is instrument and frequency independent, as we demonstrate by analyzing experimental data from two different, cantilever- and tuning fork-based, microscope setups operating in a wide frequency range up to 27.5 GHz. To benchmark the SMM results, comparison with secondary ion mass spectrometry is undertaken. Furthermore, we show SMM data on a GaAs p-n junction distinguishing p- and n-doped layers.

  16. Multichannel heterodyne radiometers with fast-scanning backward-wave oscillators for ECE measurement on HT-7 tokamak

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Poznyak, V.I.; Ploskirev, G.; Kalupin, D.; Wan, Y.X.; Xie, J.K.; Luo, J.R.; Li, J.G.; Gao, X.; Wan, B.N.; Zhang, X.D.; Wang, K.J.; Kuang, G.L.

    2001-01-01

    Two sets of fast-scanning heterodyne radiometer receiver systems employing backward-wave oscillators (BWOs) in 78-118 and 118-178 GHz were developed and installed for electron cyclotron emission (ECE) measurements on HT-7 superconducting tokamak. The double sideband (DSB) radiometer in 78-118 GHz measures 16 ECE frequency points with a scanning time period of 0.65 ms. The other radiometer in 118-178 GHz consists of one independent channel of DSB heterodyne receiver with intermediate frequency (IF) of 100-500 MHz and two channels of single sideband (SSB) heterodyne receiver that are sensitive to upper sideband and lower sideband individually; the IF frequency of the SSB channels are 1.5 GHz around the local oscillator frequencies with 1 GHz bandwidth. By employing a novel design, this unique radiometer measures 3 ECE frequency points at each of the 16 local oscillator frequency points in 118-178 GHz, and the full band can be swept in 0.65 ms period, thus the radiometer measures 48 ECE frequency points in 0.65 ms in principle. Each of the local oscillators' frequency points can be preset by program to meet specific physics interests. Horizontal view of ECE was installed to measure electron temperature profiles; vertically viewing optics along a perpendicular chord was also installed to study nonthermal ECE spectra. Preliminary measurement results were presented during ohmic and pellet injection plasmas

  17. An Analysis of the High Frequency Vibrations in Early Thematic Mapper Scenes

    Science.gov (United States)

    Kogut, J.; Larduinat, E.

    1985-01-01

    The motion of the mirrors in the thematic mapper (TM) and multispectral scanner (MSS) instruments, and the motion of other devices, such as the TDRSS antenna drive, and solar array drives onboard LANDSAT-4 cause vibrations to propagate through the spacecraft. These vibrations as well as nonlinearities in the scanning motion of the TM mirror can cause the TM detectors to point away from their nominal positions. Two computer programs, JITTER and SCDFT, were developed as part of the LANDSAT-D Assessment System (LAS), Products and Procedures Analysis (PAPA) program to evaluate the potential effect of high frequency vibrations on the final TM image. The maximum overlap and underlap which were observed for early TM scenes are well within specifications for the ground processing system. The cross scan and scan high frequency vibrations are also within the specifications cited for the flight system.

  18. Laser safety in design of near-infrared scanning LIDARs

    Science.gov (United States)

    Zhu, X.; Elgin, D.

    2015-05-01

    3D LIDARs (Light Detection and Ranging) with 1.5μm nanosecond pulse lasers have been increasingly used in different applications. The main reason for their popularity is that these LIDARs have high performance while at the same time can be made eye-safe. Because the laser hazard effect on eyes or skin at this wavelength region (industrial mining applications. We have incorporated the laser safety requirements in the LIDAR design and conducted laser safety analysis for different operational scenarios. While 1.5μm is normally said to be the eye-safe wavelength, in reality a high performance 3D LIDAR needs high pulse energy, small beam size and high pulse repetition frequency (PRF) to achieve long range, high resolution and high density images. The resulting radiant exposure of its stationary beam could be many times higher than the limit for a Class 1 laser device. Without carefully choosing laser and scanning parameters, including field-of-view, scan speed and pattern, a scanning LIDAR can't be eye- or skin-safe based only on its wavelength. This paper discusses the laser safety considerations in the design of eye-safe scanning LIDARs, including laser pulse energy, PRF, beam size and scanning parameters in two basic designs of scanning mechanisms, i.e. galvanometer based scanner and Risley prism based scanner. The laser safety is discussed in terms of device classification, nominal ocular hazard distance (NOHD) and safety glasses optical density (OD).

  19. Near-field scanning optical microscopy using polymethylmethacrylate optical fiber probes

    International Nuclear Information System (INIS)

    Chibani, H.; Dukenbayev, K.; Mensi, M.; Sekatskii, S.K.; Dietler, G.

    2010-01-01

    We report the first use of polymethylmethacrylate (PMMA) optical fiber-made probes for scanning near-field optical microscopy (SNOM). The sharp tips were prepared by chemical etching of the fibers in ethyl acetate, and the probes were prepared by proper gluing of sharpened fibers onto the tuning fork in the conditions of the double resonance (working frequency of a tuning fork coincides with the resonance frequency of dithering of the free-standing part of the fiber) reported earlier for the case of glass fibers. Quality factors of the probes in the range 2000-6000 were obtained, which enables the realization of an excellent topographical resolution including state-of-art imaging of single DNA molecules. Near-field optical performance of the microscope is illustrated by the Photon Scanning Tunneling Microscope images of fluorescent beads with a diameter of 100 nm. The preparation of these plastic fiber probes proved to be easy, needs no hazardous material and/or procedures, and typical lifetime of a probe essentially exceeds that characteristic for the glass fiber probe.

  20. An interchangeable scanning Hall probe/scanning SQUID microscope

    International Nuclear Information System (INIS)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin; Chen, Tse-Jun; Wang, M. J.; Ling, D. C.; Chi, C. C.; Chen, Jeng-Chung

    2014-01-01

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10 −7 T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La 2/3 Ca 1/3 MnO 3 thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K

  1. 5 V Compatible Two-Axis PZT Driven MEMS Scanning Mirror with Mechanical Leverage Structure for Miniature LiDAR Application.

    Science.gov (United States)

    Ye, Liangchen; Zhang, Gaofei; You, Zheng

    2017-03-05

    The MEMS (Micro-Electronical Mechanical System) scanning mirror is an optical MEMS device that can scan laser beams across one or two dimensions. MEMS scanning mirrors can be applied in a variety of applications, such as laser display, bio-medical imaging and Light Detection and Ranging (LiDAR). These commercial applications have recently created a great demand for low-driving-voltage and low-power MEMS mirrors. However, no reported two-axis MEMS scanning mirror is available for usage in a universal supplying voltage such as 5 V. In this paper, we present an ultra-low voltage driven two-axis MEMS scanning mirror which is 5 V compatible. In order to realize low voltage and low power, a two-axis MEMS scanning mirror with mechanical leverage driven by PZT (Lead zirconate titanate) ceramic is designed, modeled, fabricated and characterized. To further decrease the power of the MEMS scanning mirror, a new method of impedance matching for PZT ceramic driven by a two-frequency mixed signal is established. As experimental results show, this MEMS scanning mirror reaches a two-axis scanning angle of 41.9° × 40.3° at a total driving voltage of 4.2 Vpp and total power of 16 mW. The effective diameter of reflection of the mirror is 2 mm and the operating frequencies of two-axis scanning are 947.51 Hz and 1464.66 Hz, respectively.

  2. An interchangeable scanning Hall probe/scanning SQUID microscope

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chiu-Chun; Lin, Hui-Ting; Wu, Sing-Lin [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Chen, Tse-Jun; Wang, M. J. [Institute of Astronomy and Astrophysics, Academia Sinica, Taipei 10617, Taiwan (China); Ling, D. C. [Department of Physics, Tamkang University, Tamsui Dist., New Taipei City 25137, Taiwan (China); Chi, C. C.; Chen, Jeng-Chung [Department of Physics, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Frontier Research Center on Fundamental and Applied Sciences of Matters, National Tsing Hua University, Hsinchu 30013, Taiwan (China)

    2014-08-15

    We have constructed a scanning probe microscope for magnetic imaging, which can function as a scanning Hall probe microscope (SHPM) and as a scanning SQUID microscope (SSM). The scanning scheme, applicable to SHPM and SSM, consists of a mechanical positioning (sub) micron-XY stage and a flexible direct contact to the sample without a feedback control system for the Z-axis. With the interchangeable capability of operating two distinct scanning modes, our microscope can incorporate the advantageous functionalities of the SHPM and SSM with large scan range up to millimeter, high spatial resolution (⩽4 μm), and high field sensitivity in a wide range of temperature (4.2 K-300 K) and magnetic field (10{sup −7} T-1 T). To demonstrate the capabilities of the system, we present magnetic images scanned with SHPM and SSM, including a RbFeB magnet and a nickel grid pattern at room temperature, surface magnetic domain structures of a La{sub 2/3}Ca{sub 1/3}MnO{sub 3} thin film at 77 K, and superconducting vortices in a striped niobium film at 4.2 K.

  3. Snap Down Voltage of a Fast-Scanning Micromirror with Vertical Electrostatic Combdrives

    Science.gov (United States)

    Wada, Hiroyuki; Lee, Daesung; Zappe, Stefan; Krishnamoorthy, Uma; Solgaard, Olav

    2004-02-01

    The parallel transition mode of the snap down of a fast-scanning mirror with vertical combdrives was analyzed. The snap down voltage of such a mirror significantly decreased when offsets between the ideal and actual upper movable comb teeth were more than 0.1 μm. When gap between the upper and lower comb teeth was decreased to increase torque, snap down voltage significantly decreased. The largest offset is induced by the lithography step in the fabrication process of the mirror. Self-alignment is required to increase the resonant frequency of the scanning mirror.

  4. A modular scanning tunneling microscope with an interchangeable elastic closed cell and external actuators

    International Nuclear Information System (INIS)

    Bjarnason, Elias H.; Arnalds, Unnar B.; Olafsson, Sveinn

    2006-01-01

    We introduce a novel modular cell based scanning tunneling microscope with external piezoelectric actuators. A tip and a sample are contained in a closed interchangeable cell, consisting of a stiff top plate and a bottom part, fastened together by an elastic material. The bottom part, containing a scanning tip, is fastened to a base unit while the top plate, containing a sample, is capable of scanning motion by external piezoelectric actuators mounted in the same base unit. The actuators are pre-loaded by the deformation of the elastic material of the cell, giving an increased stability. This design is expected to simplify the scanning tunneling microscope (STM) operation in difficult environments greatly by enclosing only the tip and sample in a small cell-module, which is pluggable to a scanning mechanism and other supportive functionalities. A frequency characterization and an image scan showing atomic resolution of highly oriented graphite in air, at room temperature, is presented

  5. Optical frequency comb Faraday rotation spectroscopy

    Science.gov (United States)

    Johansson, Alexandra C.; Westberg, Jonas; Wysocki, Gerard; Foltynowicz, Aleksandra

    2018-05-01

    We demonstrate optical frequency comb Faraday rotation spectroscopy (OFC-FRS) for broadband interference-free detection of paramagnetic species. The system is based on a femtosecond doubly resonant optical parametric oscillator and a fast-scanning Fourier transform spectrometer (FTS). The sample is placed in a DC magnetic field parallel to the light propagation. Efficient background suppression is implemented via switching the direction of the field on consecutive FTS scans and subtracting the consecutive spectra, which enables long-term averaging. In this first demonstration, we measure the entire Q- and R-branches of the fundamental band of nitric oxide in the 5.2-5.4 µm range and achieve good agreement with a theoretical model.

  6. NEW SCANNING DEVICE FOR SCANNING TUNNELING MICROSCOPE APPLICATIONS

    NARCIS (Netherlands)

    SAWATZKY, GA; Koops, Karl Richard

    A small, single piezo XYZ translator has been developed. The device has been used as a scanner for a scanning tunneling microscope and has been tested successfully in air and in UHV. Its simple design results in a rigid and compact scanning unit which permits high scanning rates.

  7. Nuclear Scans

    Science.gov (United States)

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  8. Versatile mid-infrared frequency-comb referenced sub-Doppler spectrometer

    Science.gov (United States)

    Gambetta, A.; Vicentini, E.; Coluccelli, N.; Wang, Y.; Fernandez, T. T.; Maddaloni, P.; De Natale, P.; Castrillo, A.; Gianfrani, L.; Laporta, P.; Galzerano, G.

    2018-04-01

    We present a mid-IR high-precision spectrometer capable of performing accurate Doppler-free measurements with absolute calibration of the optical axis and high signal-to-noise ratio. The system is based on a widely tunable mid-IR offset-free frequency comb and a Quantum-Cascade-Laser (QCL). The QCL emission frequency is offset locked to one of the comb teeth to provide absolute-frequency calibration, spectral-narrowing, and accurate fine frequency tuning. Both the comb repetition frequency and QCL-comb offset frequency can be modulated to provide, respectively, slow- and fast-frequency-calibrated scanning capabilities. The characterisation of the spectrometer is demonstrated by recording sub-Doppler saturated absorption features of the CHF3 molecule at around 8.6 μm with a maximum signal-to-noise ratio of ˜7 × 103 in 10 s integration time, frequency-resolution of 160 kHz, and accuracy of less than 10 kHz.

  9. Versatile mid-infrared frequency-comb referenced sub-Doppler spectrometer

    Directory of Open Access Journals (Sweden)

    A. Gambetta

    2018-04-01

    Full Text Available We present a mid-IR high-precision spectrometer capable of performing accurate Doppler-free measurements with absolute calibration of the optical axis and high signal-to-noise ratio. The system is based on a widely tunable mid-IR offset-free frequency comb and a Quantum-Cascade-Laser (QCL. The QCL emission frequency is offset locked to one of the comb teeth to provide absolute-frequency calibration, spectral-narrowing, and accurate fine frequency tuning. Both the comb repetition frequency and QCL-comb offset frequency can be modulated to provide, respectively, slow- and fast-frequency-calibrated scanning capabilities. The characterisation of the spectrometer is demonstrated by recording sub-Doppler saturated absorption features of the CHF3 molecule at around 8.6 μm with a maximum signal-to-noise ratio of ∼7 × 103 in 10 s integration time, frequency-resolution of 160 kHz, and accuracy of less than 10 kHz.

  10. Computed tomographic scanning in patients presenting with chief complaint of headache without focal neurological signs

    International Nuclear Information System (INIS)

    Halim, A.; Khalid, W.; Haq, A.U.

    2017-01-01

    To determine the frequency of positive computed tomographic (CT)scan findings in patients presenting at PNS Shifa Hospital Karachi with chief complaint of headache without focal neurological signs. Study Design: Cross sectional descriptive study. Place and Duration of Study: The study was conducted at the Radiology department, PNS Shifa Hospital Karachi from Dec 2011 to Jun 2012. Patients and Methods: This cross-sectional descriptive study included referred patients with complaint of headache of one month duration or more without focal neurological signs. No gender restriction was considered and patients of age more than 14 years were included. Patients with headache due to other known clinical disorders such as intracranial neoplasm and stroke were excluded. Patients with focal neurological signs such as hemiparesis, cerebellar signs and cranial nerve palsies were also excluded from the study. A total of 105 patients were included in the study through non probability consecutive sampling. Informed written consent was taken from the patients by explaining all the risks and benefits of the study and use of data for research and publication. Plain CT scan brain was done by trained CT technician and reporting of CT scan was done by consultant radiologist. CT scan was done on Toshiba Scanner Aquilion-64 CT Scan machine. The imaging protocol consisted of appropriately angled continuous 5mm thick axial slices for the posterior fossa and 10 mm thick slices for the rest of brain from the base of skull to the vertex. Data was collected through a specially structured proforma. Confidentiality of the patients record was maintained. Results: Majority of the patients were between 31-40 years of age i.e. 29.52 percent (n=31) and mean and SD was calculated as 34.24 +- 8.72 years, 54.29 percent (n=57) females and 45.71 percent (n=48) male patients, frequency of positive CT scan findings in patients with chief complaint of headache without focal neurological signs was recorded as

  11. Multiphoton minimal inertia scanning for fast acquisition of neural activity signals

    Science.gov (United States)

    Schuck, Renaud; Go, Mary Ann; Garasto, Stefania; Reynolds, Stephanie; Dragotti, Pier Luigi; Schultz, Simon R.

    2018-04-01

    Objective. Multi-photon laser scanning microscopy provides a powerful tool for monitoring the spatiotemporal dynamics of neural circuit activity. It is, however, intrinsically a point scanning technique. Standard raster scanning enables imaging at subcellular resolution; however, acquisition rates are limited by the size of the field of view to be scanned. Recently developed scanning strategies such as travelling salesman scanning (TSS) have been developed to maximize cellular sampling rate by scanning only select regions in the field of view corresponding to locations of interest such as somata. However, such strategies are not optimized for the mechanical properties of galvanometric scanners. We thus aimed to develop a new scanning algorithm which produces minimal inertia trajectories, and compare its performance with existing scanning algorithms. Approach. We describe here the adaptive spiral scanning (SSA) algorithm, which fits a set of near-circular trajectories to the cellular distribution to avoid inertial drifts of galvanometer position. We compare its performance to raster scanning and TSS in terms of cellular sampling frequency and signal-to-noise ratio (SNR). Main Results. Using surrogate neuron spatial position data, we show that SSA acquisition rates are an order of magnitude higher than those for raster scanning and generally exceed those achieved by TSS for neural densities comparable with those found in the cortex. We show that this result also holds true for in vitro hippocampal mouse brain slices bath loaded with the synthetic calcium dye Cal-520 AM. The ability of TSS to ‘park’ the laser on each neuron along the scanning trajectory, however, enables higher SNR than SSA when all targets are precisely scanned. Raster scanning has the highest SNR but at a substantial cost in number of cells scanned. To understand the impact of sampling rate and SNR on functional calcium imaging, we used the Cramér-Rao Bound on evoked calcium traces recorded

  12. Phase and fringe order determination in wavelength scanning interferometry.

    Science.gov (United States)

    Moschetti, Giuseppe; Forbes, Alistair; Leach, Richard K; Jiang, Xiang; O'Connor, Daniel

    2016-04-18

    A method to obtain unambiguous surface height measurements using wavelength scanning interferometry with an improved repeatability, comparable to that obtainable using phase shifting interferometry, is reported. Rather than determining the conventional fringe frequency-derived z height directly, the method uses the frequency to resolve the fringe order ambiguity, and combine this information with the more accurate and repeatable fringe phase derived z height. A theoretical model to evaluate the method's performance in the presence of additive noise is derived and shown to be in good agreement with experiments. The measurement repeatability is improved by a factor of ten over that achieved when using frequency information alone, reaching the sub-nanometre range. Moreover, the z-axis non-linearity (bleed-through or ripple error) is reduced by a factor of ten. These order of magnitude improvements in measurement performance are demonstrated through a number of practical measurement examples.

  13. Sub-nanosecond time-resolved near-field scanning magneto-optical microscope.

    Science.gov (United States)

    Rudge, J; Xu, H; Kolthammer, J; Hong, Y K; Choi, B C

    2015-02-01

    We report on the development of a new magnetic microscope, time-resolved near-field scanning magneto-optical microscope, which combines a near-field scanning optical microscope and magneto-optical contrast. By taking advantage of the high temporal resolution of time-resolved Kerr microscope and the sub-wavelength spatial resolution of a near-field microscope, we achieved a temporal resolution of ∼50 ps and a spatial resolution of microscope, the magnetic field pulse induced gyrotropic vortex dynamics occurring in 1 μm diameter, 20 nm thick CoFeB circular disks has been investigated. The microscope provides sub-wavelength resolution magnetic images of the gyrotropic motion of the vortex core at a resonance frequency of ∼240 MHz.

  14. Frequency modulation spectroscopy with a THz quantum-cascade laser.

    Science.gov (United States)

    Eichholz, R; Richter, H; Wienold, M; Schrottke, L; Hey, R; Grahn, H T; Hübers, H-W

    2013-12-30

    We report on a terahertz spectrometer for high-resolution molecular spectroscopy based on a quantum-cascade laser. High-frequency modulation (up to 50 MHz) of the laser driving current produces a simultaneous modulation of the frequency and amplitude of the laser output. The modulation generates sidebands, which are symmetrically positioned with respect to the laser carrier frequency. The molecular transition is probed by scanning the sidebands across it. In this way, the absorption and the dispersion caused by the molecular transition are measured. The signals are modeled by taking into account the simultaneous modulation of the frequency and amplitude of the laser emission. This allows for the determination of the strength of the frequency as well as amplitude modulation of the laser and of molecular parameters such as pressure broadening.

  15. Direct Frequency Comb Spectroscopy of Alkali Atoms

    Science.gov (United States)

    Pradhananga, Trinity; Palm, Christopher; Nguyen, Khoa; Guttikonda, Srikanth; Kimball, Derek Jackson

    2011-11-01

    We are using direct frequency comb spectroscopy to study transition frequencies and excited state hyperfine structure in potassium and rubidium using 2-photon transitions excited directly with the frequency-doubled output of a erbium fiber optical frequency comb. The frequency comb output is directed in two counterpropagating directions through a vapor cell containing the atomic vapor of interest. A pair of optical filters is used to select teeth of the comb in order to identify the transition wavelengths. A photomultiplier tube (PMT) measures fluorescence from a decay channel wavelength selected with another optical filter. Using different combinations of filters enables a wide range of transitions to be investigated. By scanning the repetition rate, a Doppler-free spectrum can be obtained enabling kHz-resolution spectral measurements. The thermal motion of the atoms in the vapor cell actually eliminates the need to fine-tune the offset frequency and repetition rate, alleviating a somewhat challenging requirement for spectroscopy of cold atoms. Our investigations are laying the groundwork for a long-term research program to use direct frequency comb spectroscopy to understand the complex spectra of rare-earth atoms.

  16. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  17. Metrological large range scanning probe microscope

    International Nuclear Information System (INIS)

    Dai Gaoliang; Pohlenz, Frank; Danzebrink, Hans-Ulrich; Xu Min; Hasche, Klaus; Wilkening, Guenter

    2004-01-01

    We describe a metrological large range scanning probe microscope (LR-SPM) with an Abbe error free design and direct interferometric position measurement capability, aimed at versatile traceable topographic measurements that require nanometer accuracy. A dual-stage positioning system was designed to achieve both a large measurement range and a high measurement speed. This dual-stage system consists of a commercially available stage, referred to as nanomeasuring machine (NMM), with a motion range of 25 mmx25 mmx5 mm along x, y, and z axes, and a compact z-axis piezoelectric positioning stage (compact z stage) with an extension range of 2 μm. The metrological LR-SPM described here senses the surface using a stationary fixed scanning force microscope (SFM) head working in contact mode. During operation, lateral scanning of the sample is performed solely by the NMM. Whereas the z motion, controlled by the SFM signal, is carried out by a combination of the NMM and the compact z stage. In this case the compact z stage, with its high mechanical resonance frequency (greater than 20 kHz), is responsible for the rapid motion while the NMM simultaneously makes slower movements over a larger motion range. To reduce the Abbe offset to a minimum the SFM tip is located at the intersection of three interferometer measurement beams orientated in x, y, and z directions. To improve real time performance two high-end digital signal processing (DSP) systems are used for NMM positioning and SFM servocontrol. Comprehensive DSP firmware and Windows XP-based software are implemented, providing a flexible and user-friendly interface. The instrument is able to perform large area imaging or profile scanning directly without stitching small scanned images. Several measurements on different samples such as flatness standards, nanostep height standards, roughness standards as well as sharp nanoedge samples and 1D gratings demonstrate the outstanding metrological capabilities of the instrument

  18. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  19. Frequency-Tunable antenna by input-impedance-tunable CMOS RF-Frontend

    NARCIS (Netherlands)

    Haider, Nadia; Oude Alink, M.S.; Caratelli, Diego; Klumperink, Eric A.M.; Yarovoy, Alexander G.

    2013-01-01

    Variable-impedance matching between the antenna and the RF-frontend provides several potential advantages, including changing operational frequency, compensating for unintentional mismatch, improving scanning capability, and reducing noise and interference signal levels. In this article a concept of

  20. Nondestructive Evaluation of Concrete Bridge Decks with Automated Acoustic Scanning System and Ground Penetrating Radar.

    Science.gov (United States)

    Sun, Hongbin; Pashoutani, Sepehr; Zhu, Jinying

    2018-06-16

    Delamanintions and reinforcement corrosion are two common problems in concrete bridge decks. No single nondestructive testing method (NDT) is able to provide comprehensive characterization of these defects. In this work, two NDT methods, acoustic scanning and Ground Penetrating Radar (GPR), were used to image a straight concrete bridge deck and a curved intersection ramp bridge. An acoustic scanning system has been developed for rapid delamination mapping. The system consists of metal-ball excitation sources, air-coupled sensors, and a GPS positioning system. The acoustic scanning results are presented as a two-dimensional image that is based on the energy map in the frequency range of 0.5⁻5 kHz. The GPR scanning results are expressed as the GPR signal attenuation map to characterize concrete deterioration and reinforcement corrosion. Signal processing algorithms for both methods are discussed. Delamination maps from the acoustic scanning are compared with deterioration maps from the GPR scanning on both bridges. The results demonstrate that combining the acoustic and GPR scanning results will provide a complementary and comprehensive evaluation of concrete bridge decks.

  1. Bone scanning as a routine examination of patients with mammary carcinoma; a critical consideration

    International Nuclear Information System (INIS)

    Heslinga, J.M.; Pauwels, E.K.J.; Zwaveling, A.

    1982-01-01

    The usefulness of bone scanning as a routine examination was evaluated in 136 female patients with mammary carcinoma of whom 81 were staged as Columbia A and 55 as Columbia B/C. The preoperative bone scanning was positive in only 4 patients (2.9%). Consequently, bone scanning is no longer performed in the authors clinic for the preoperative detection of skeletal metastases. Bone scanning as a routine examination at 6-month intervals does not appear to be useful for the first 4 years of the follow-up, either. Most of the patients with a positive bone scan displayed other signs of skeletal metastases at the same time, such as ostealgia and a raised serum alkaline phosphatase level. Further increase of the frequency of bone scanning during the follow-up period would increase the costs considerably, almost prohibitively, even apart from the question whether such a measure might indeed significantly influence the patient's prognosis. The authors conclude that bone scanning should only be performed on the basis of the anamnesis, physical and laboratory findings, both prior to operation and during the follow-up period. (Auth.)

  2. Frequency-comb-assisted broadband precision spectroscopy with cascaded diode lasers

    DEFF Research Database (Denmark)

    Liu, Junqiu; Brasch, Victor; Pfeiffer, Martin H. P.

    2016-01-01

    Frequency-comb-assisted diode laser spectroscopy, employing both the accuracy of an optical frequency comb and the broad wavelength tuning range of a tunable diode laser, has been widely used in many applications. In this Letter, we present a novel method using cascaded frequency agile diode lasers......, which allows us to extend the measurement bandwidth to 37.4 THz (1355-1630 nm) at megahertz resolution with scanning speeds above 1 THz/s. It is demonstrated as a useful tool to characterize a broadband spectrum for molecular spectroscopy, and in particular it enables us to characterize the dispersion...

  3. Geometrical Feature Extraction from Ultrasonic Time Frequency Responses: An Application to Nondestructive Testing of Materials

    Directory of Open Access Journals (Sweden)

    Naranjo Valery

    2010-01-01

    Full Text Available Signal processing is an essential tool in nondestructive material characterization. Pulse-echo inspection with ultrasonic energy provides signals (A-scans that can be processed in order to obtain parameters which are related to physical properties of inspected materials. Conventional techniques are based on the use of a short-term frequency analysis of the A-scan, obtaining a time-frequency response (TFR, to isolate the evolution of the different frequency-dependent parameters. The application of geometrical estimators to TFRs provides an innovative way to complement conventional techniques based on the one-dimensional evolution of an A-scan extracted parameter (central or centroid frequency, bandwidth, etc.. This technique also provides an alternative method of obtaining similar meaning and less variance estimators. A comparative study of conventional versus new proposed techniques is presented in this paper. The comparative study shows that working with binarized TFRs and the use of shape descriptors provide estimates with lower bias and variance than conventional techniques. Real scattering materials, with different scatterer sizes, have been measured in order to demonstrate the usefulness of the proposed estimators to distinguish among scattering soft tissues. Superior results, using the proposed estimators in real measures, were obtained when classifying according to mean scatterer size.

  4. Buried Object Detection Method Using Optimum Frequency Range in Extremely Shallow Underground

    Science.gov (United States)

    Sugimoto, Tsuneyoshi; Abe, Touma

    2011-07-01

    We propose a new detection method for buried objects using the optimum frequency response range of the corresponding vibration velocity. Flat speakers and a scanning laser Doppler vibrometer (SLDV) are used for noncontact acoustic imaging in the extremely shallow underground. The exploration depth depends on the sound pressure, but it is usually less than 10 cm. Styrofoam, wood (silver fir), and acrylic boards of the same size, different size styrofoam boards, a hollow toy duck, a hollow plastic container, a plastic container filled with sand, a hollow steel can and an unglazed pot are used as buried objects which are buried in sand to about 2 cm depth. The imaging procedure of buried objects using the optimum frequency range is given below. First, the standardized difference from the average vibration velocity is calculated for all scan points. Next, using this result, underground images are made using a constant frequency width to search for the frequency response range of the buried object. After choosing an approximate frequency response range, the difference between the average vibration velocity for all points and that for several points that showed a clear response is calculated for the final confirmation of the optimum frequency range. Using this optimum frequency range, we can obtain the clearest image of the buried object. From the experimental results, we confirmed the effectiveness of our proposed method. In particular, a clear image of the buried object was obtained when the SLDV image was unclear.

  5. Circumvention of fluorophore photobleaching in fluorescence fluctuation experiments: a beam scanning approach.

    Science.gov (United States)

    Satsoura, Dmitri; Leber, Brian; Andrews, David W; Fradin, Cécile

    2007-04-23

    Photobleaching is a fluorophore-damaging process that commonly afflicts single-molecule fluorescence studies. It becomes an especially severe problem in fluorescence fluctuation experiments when studying slowly diffusing particles. One way to circumvent this problem is to use beam scanning to decrease the residence time of the fluorophores in the excitation volume. We report a systematic study of the effects of circular beam scanning on the photobleaching of fluorescent particles as observed in single-photon excitation fluorescence fluctuation experiments. We start by deriving a simple expression relating the average detected fluorescence to the photobleaching cross section of the fluorophores. We then perform numerical calculations of the spatial distribution of fluorescent particles in order to understand under which conditions beam scanning can prevent the formation of a photobleaching hole. To support these predictions, we show experimental results obtained for large unilamellar vesicles containing a small amount of the fluorescent lipophilic tracer DiD. We establish the required scanning radius and frequency range in order to obtain sufficient reduction of the photobleaching effect for that system. From the detected increase in fluorescence upon increase in scanning speed, we estimate the photobleaching cross section of DiD.

  6. Probing the local microwave properties of superconducting thin films by a scanning microwave near-field microscope

    CERN Document Server

    Wu, L Y; Wang, K L; Jiang, T; Kang, L; Yang, S Z; Wu, P H

    2002-01-01

    In this paper, we present our approach to probe the local microwave properties of superconducting thin films by using the microwave near-field scanning technique. We have employed a coaxial cavity together with a niobium tip as the probe and established a scanning sample stage cooled by liquid nitrogen to study thin film devices at low temperature in our scanning microwave near-field microscope. Nondestructive images have been obtained on the inhomogeneity of the YBaCuO superconducting thin films at microwave frequency. We believe that these results would be helpful in evaluating the microwave performance of the devices.

  7. Molecular quantum control landscapes in von Neumann time-frequency phase space

    Science.gov (United States)

    Ruetzel, Stefan; Stolzenberger, Christoph; Fechner, Susanne; Dimler, Frank; Brixner, Tobias; Tannor, David J.

    2010-10-01

    Recently we introduced the von Neumann representation as a joint time-frequency description for femtosecond laser pulses and suggested its use as a basis for pulse shaping experiments. Here we use the von Neumann basis to represent multidimensional molecular control landscapes, providing insight into the molecular dynamics. We present three kinds of time-frequency phase space scanning procedures based on the von Neumann formalism: variation of intensity, time-frequency phase space position, and/or the relative phase of single subpulses. The shaped pulses produced are characterized via Fourier-transform spectral interferometry. Quantum control is demonstrated on the laser dye IR140 elucidating a time-frequency pump-dump mechanism.

  8. Vibration compensated high-resolution scanning white-light Linnik-interferometer

    Science.gov (United States)

    Tereschenko, Stanislav; Lehmann, Peter; Gollor, Pascal; Kuehnhold, Peter

    2017-06-01

    We present a high-resolution Linnik scanning white-light interferometer (SWLI) with integrated distance measuring interferometer (DMI) for close-to-machine applications in the presence of environmental vibrations. The distance, measured by DMI during the depth-scan, is used for vibration compensation of SWLI signals. The reconstruction of the white-light interference signals takes place after measurement by reordering the captured images in accordance with their real positions obtained by the DMI and subsequent trigonometrical approximation. This system is the further development of our previously presented Michelson-interferometer. We are able to compensate for arbitrary vibrations with frequencies up to several kilohertz and amplitudes in the lower micrometer range. Completely distorted SWLI signals can be reconstructed and the surface topography can be obtained with high accuracy. We demonstrate the feasibility of the method by examples of practical measurements with and without vibrational disturbances.

  9. Differential scanning calorimetry (DSC) of semicrystalline polymers.

    Science.gov (United States)

    Schick, C

    2009-11-01

    Differential scanning calorimetry (DSC) is an effective analytical tool to characterize the physical properties of a polymer. DSC enables determination of melting, crystallization, and mesomorphic transition temperatures, and the corresponding enthalpy and entropy changes, and characterization of glass transition and other effects that show either changes in heat capacity or a latent heat. Calorimetry takes a special place among other methods. In addition to its simplicity and universality, the energy characteristics (heat capacity C(P) and its integral over temperature T--enthalpy H), measured via calorimetry, have a clear physical meaning even though sometimes interpretation may be difficult. With introduction of differential scanning calorimeters (DSC) in the early 1960s calorimetry became a standard tool in polymer science. The advantage of DSC compared with other calorimetric techniques lies in the broad dynamic range regarding heating and cooling rates, including isothermal and temperature-modulated operation. Today 12 orders of magnitude in scanning rate can be covered by combining different types of DSCs. Rates as low as 1 microK s(-1) are possible and at the other extreme heating and cooling at 1 MK s(-1) and higher is possible. The broad dynamic range is especially of interest for semicrystalline polymers because they are commonly far from equilibrium and phase transitions are strongly time (rate) dependent. Nevertheless, there are still several unsolved problems regarding calorimetry of polymers. I try to address a few of these, for example determination of baseline heat capacity, which is related to the problem of crystallinity determination by DSC, or the occurrence of multiple melting peaks. Possible solutions by using advanced calorimetric techniques, for example fast scanning and high frequency AC (temperature-modulated) calorimetry are discussed.

  10. The renal scan in pregnant renal transplant patients

    International Nuclear Information System (INIS)

    Goldstein, H.A.; Ziessman, H.A.; Fahey, F.H.; Collea, J.V.; Alijani, M.R.; Helfrich, G.B.

    1985-01-01

    With the greater frequency of renal transplant surgery, more female pts are becoming pregnant and carrying to term. In the renal allograft blood vessels and ureter may be compressed resulting in impaired renal function and/or, hypertension. Toxemia of pregnancy is seen more frequently than normal. Radionuclide renal scan monitoring may be of significant value in this high risk obstetrical pt. After being maintained during the pregnancy, renal function may also deteriorate in the post partum period. 5 pregnant renal transplant pts who delivered live babies had renal studies with Tc-99m DTPA to assess allograft perfusion and function. No transplanted kidney was lost during or after pregnancy as a result of pregnancy. No congenital anomalies were associated with transplant management. 7 studies were performed on these 5 pts. The 7 scans all showed the uterus/placenta. The bladder was always distorted. The transplanted kidney was rotated to a more vertical position in 3 pts. The radiation dose to the fetus is calculated at 0.024 rad/mCi administered. This study demonstrates the anatomic and physiologic alterations expected in the transplanted kidney during pregnancy when evaluated by renal scan and that the radiation burden may be acceptable in management of these pts

  11. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  12. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  13. Non-Linear Structural Dynamics Characterization using a Scanning Laser Vibrometer

    Science.gov (United States)

    Pai, P. F.; Lee, S.-Y.

    2003-01-01

    This paper presents the use of a scanning laser vibrometer and a signal decomposition method to characterize non-linear dynamics of highly flexible structures. A Polytec PI PSV-200 scanning laser vibrometer is used to measure transverse velocities of points on a structure subjected to a harmonic excitation. Velocity profiles at different times are constructed using the measured velocities, and then each velocity profile is decomposed using the first four linear mode shapes and a least-squares curve-fitting method. From the variations of the obtained modal \\ielocities with time we search for possible non-linear phenomena. A cantilevered titanium alloy beam subjected to harmonic base-excitations around the second. third, and fourth natural frequencies are examined in detail. Influences of the fixture mass. gravity. mass centers of mode shapes. and non-linearities are evaluated. Geometrically exact equations governing the planar, harmonic large-amplitude vibrations of beams are solved for operational deflection shapes using the multiple shooting method. Experimental results show the existence of 1:3 and 1:2:3 external and internal resonances. energy transfer from high-frequency modes to the first mode. and amplitude- and phase- modulation among several modes. Moreover, the existence of non-linear normal modes is found to be questionable.

  14. MRI evaluation of the anterolateral ligament of the knee: assessment in routine 1.5-T scans

    International Nuclear Information System (INIS)

    Partezani Helito, Camilo; Pecora, Jose Ricardo; Camanho, Gilberto Luis; Kawamura Demange, Marco; Partezani Helito, Paulo Victor; Pereira Costa, Hugo; Bordalo-Rodrigues, Marcelo

    2014-01-01

    This study evaluated the ability of routine 1.5-T MRI scans to visualize the anterolateral ligament (ALL) and describe its path and anatomic relations with lateral knee structures. Thirty-nine 1.5-T MRI scans of the knee were evaluated. The scans included an MRI knee protocol with T1-weighted sequences, T2-weighted sequences with fat saturation, and proton density (PD)-weighted fast spin-echo sequences. Two radiologists separately reviewed all MRI scans to evaluate interobserver reliability. The ALL was divided into three portions for analyses: femoral, meniscal, and tibial. The path of the ALL was evaluated with regard to known structural parameters previously studied in this region. At least a portion of the ALL was visualized in 38 (97.8 %) cases. The meniscal portion was most visualized (94.8 %), followed by the femoral (89.7 %) and the tibial (79.4 %) portions. The three portions of the ALL were visualized in 28 (71.7 %) patients. The ALL was characterized with greater clarity on the coronal plane and was visualized as a thin, linear structure. The T1-weighted sequences showed a statistically inferior ligament visibility frequency. With regard to the T2 and PD evaluations, although the visualization frequency in PD was higher for the three portions of the ligament, only the femoral portion showed significant values. The ALL can be visualized in routine 1.5-T MRI scans. Although some of the ligament could be depicted in nearly all of the scans (97.4 %), it could only be observed in its entirety in about 71.7 % of the tests. (orig.)

  15. MRI evaluation of the anterolateral ligament of the knee: assessment in routine 1.5-T scans

    Energy Technology Data Exchange (ETDEWEB)

    Partezani Helito, Camilo; Pecora, Jose Ricardo; Camanho, Gilberto Luis; Kawamura Demange, Marco [University of Sao Paulo, Faculty of Medicine, Institute of Orthopedics and Traumatology, Knee Surgery Division, Sao Paulo (Brazil); Partezani Helito, Paulo Victor; Pereira Costa, Hugo; Bordalo-Rodrigues, Marcelo [University of Sao Paulo, Faculty of Medicine, Institute of Orthopedics and Traumatology, Musculoskeletal Radiology Department, Sao Paulo (Brazil)

    2014-10-15

    This study evaluated the ability of routine 1.5-T MRI scans to visualize the anterolateral ligament (ALL) and describe its path and anatomic relations with lateral knee structures. Thirty-nine 1.5-T MRI scans of the knee were evaluated. The scans included an MRI knee protocol with T1-weighted sequences, T2-weighted sequences with fat saturation, and proton density (PD)-weighted fast spin-echo sequences. Two radiologists separately reviewed all MRI scans to evaluate interobserver reliability. The ALL was divided into three portions for analyses: femoral, meniscal, and tibial. The path of the ALL was evaluated with regard to known structural parameters previously studied in this region. At least a portion of the ALL was visualized in 38 (97.8 %) cases. The meniscal portion was most visualized (94.8 %), followed by the femoral (89.7 %) and the tibial (79.4 %) portions. The three portions of the ALL were visualized in 28 (71.7 %) patients. The ALL was characterized with greater clarity on the coronal plane and was visualized as a thin, linear structure. The T1-weighted sequences showed a statistically inferior ligament visibility frequency. With regard to the T2 and PD evaluations, although the visualization frequency in PD was higher for the three portions of the ligament, only the femoral portion showed significant values. The ALL can be visualized in routine 1.5-T MRI scans. Although some of the ligament could be depicted in nearly all of the scans (97.4 %), it could only be observed in its entirety in about 71.7 % of the tests. (orig.)

  16. Retinal Nerve Fiber Layer Segmentation on FD-OCT Scans of Normal Subjects and Glaucoma Patients.

    Science.gov (United States)

    Mayer, Markus A; Hornegger, Joachim; Mardin, Christian Y; Tornow, Ralf P

    2010-11-08

    Automated measurements of the retinal nerve fiber layer thickness on circular OCT B-Scans provide physicians additional parameters for glaucoma diagnosis. We propose a novel retinal nerve fiber layer segmentation algorithm for frequency domain data that can be applied on scans from both normal healthy subjects, as well as glaucoma patients, using the same set of parameters. In addition, the algorithm remains almost unaffected by image quality. The main part of the segmentation process is based on the minimization of an energy function consisting of gradient and local smoothing terms. A quantitative evaluation comparing the automated segmentation results to manually corrected segmentations from three reviewers is performed. A total of 72 scans from glaucoma patients and 132 scans from normal subjects, all from different persons, composed the database for the evaluation of the segmentation algorithm. A mean absolute error per A-Scan of 2.9 µm was achieved on glaucomatous eyes, and 3.6 µm on healthy eyes. The mean absolute segmentation error over all A-Scans lies below 10 µm on 95.1% of the images. Thus our approach provides a reliable tool for extracting diagnostic relevant parameters from OCT B-Scans for glaucoma diagnosis.

  17. CT scans in young people in Northern England: trends and patterns 1993-2002

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Mark S.; Salotti, Jane A.; Metcalf, Wenhua [Newcastle University, Sir James Spence Institute, Royal Victoria Infirmary, Institute of Health and Society, Newcastle upon Tyne (United Kingdom); McHugh, Kieran [Great Ormond Street Hospital for Children NHS Trust, London (United Kingdom); Kim, Kwang P. [Kyung Hee University, Department of Nuclear Engineering, Gyeongi-Do (Korea, Republic of); Craft, Alan W. [Newcastle University, Northern Institute of Cancer Research, Sir James Spence Institute, Royal Victoria Infirmary, Newcastle upon Tyne (United Kingdom); Parker, Louise [Dalhousie University and Cancer Care Nova Scotia, Departments of Medicine and Paediatrics, Population Cancer Research Program, Halifax, NS (Canada); Ron, Elaine [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States)

    2011-07-15

    Although CT can be greatly beneficial, its relatively high radiation doses have caused public health concerns. To assess patterns in CT usage among patients aged less than 22 years in Northern England during the period 1993-2002. Electronic data were obtained from radiology information systems of all nine National Health Service trusts in the region. A total of 38,681 scans had been performed in 20,483 patients aged less than 22 years. The number of CT examinations rose, with the steepest increase between 1997 and 2000. The number of patients scanned per year increased less dramatically, with 2.24/1,000 population aged less than 22 years having one scan or more in 1993 compared to 3.54/1,000 in 2002. This reflects an increase in the median number of scans per patient, which rose from 1 in 1993 to 2 by 1999. More than 70% of CT examinations were of the head, with the number of head examinations varying with time and patient age. The frequency of CT scans in this population more than doubled during the study period. This is partly, but not wholly, explained by an increase in the number of scans per patient. (orig.)

  18. Noise-Immune Cavity-Enhanced Optical Frequency Comb Spectroscopy

    Science.gov (United States)

    Rutkowski, Lucile; Khodabakhsh, Amir; Johanssson, Alexandra C.; Foltynowicz, Aleksandra

    2015-06-01

    We present noise-immune cavity-enhanced optical frequency comb spectroscopy (NICE-OFCS), a recently developed technique for sensitive, broadband, and high resolution spectroscopy. In NICE-OFCS an optical frequency comb (OFC) is locked to a high finesse cavity and phase-modulated at a frequency precisely equal to (a multiple of) the cavity free spectral range. Since each comb line and sideband is transmitted through a separate cavity mode in exactly the same way, any residual frequency noise on the OFC relative to the cavity affects each component in an identical manner. The transmitted intensity contains a beat signal at the modulation frequency that is immune to frequency-to-amplitude noise conversion by the cavity, in a way similar to continuous wave noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS). The light transmitted through the cavity is detected with a fast-scanning Fourier-transform spectrometer (FTS) and the NICE-OFCS signal is obtained by fast Fourier transform of the synchronously demodulated interferogram. Our NICE-OFCS system is based on an Er:fiber femtosecond laser locked to a cavity with a finesse of ˜9000 and a fast-scanning FTS equipped with a high-bandwidth commercial detector. We measured NICE-OFCS signals from the 3νb{1}+νb{3} overtone band of CO_2 around 1.57 μm and achieved absorption sensitivity 6.4×10-11cm-1 Hz-1/2 per spectral element, corresponding to a minimum detectable CO_2 concentration of 25 ppb after 330 s integration time. We will describe the principles of the technique and its technical implementation, and discuss the spectral lineshapes of the NICE-OFCS signals. A. Khodabakhsh, C. Abd Alrahman, and A. Foltynowicz, Opt. Lett. 39, 5034-5037 (2014). J. Ye, L. S. Ma, and J. L. Hall, J. Opt. Soc. Am. B 15, 6-15 (1998). A. Khodabakhsh, A. C. Johansson, and A. Foltynowicz, Appl. Phys. B (2015) doi:10.1007/s00340-015-6010-7.

  19. Bone scan and joint scan of hands and feet in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Carpentier, N.; Verbeke, S.; Perdrisot, R.; Grilo, R.M.; Quenesson, E.; Bonnet, C.; Vergne, P.; Treves, R.; Bertin, P.; Boutros-Toni, F.

    2000-01-01

    The aim of this study was to determine the ability of joint scan and bone scan of hands and feet, in patients with rheumatoid arthritis, to localize the altered joints. The sensitivity, the specificity, the positive predictive value (PPV) and the negative predictive value (NPV) of joint scan were determined in comparison with clinical joint assessment. Fifteen patients (780 joints) were clinically examined (pain and synovitis); during the same day, a bone scan and a joint scan were realized by oxidronate 99m Tc intravenous injection. Patients were scanned 5 minutes (tissual time, T t ) and 3 hours 1/4 (bone time, T 0 ) after the administration. The uptake of the bi-phosphonate was evaluated with a qualitative method using a grey scale. The uptake of 99m Tc oxidronate was quantitated using an extra-articular region of interest. The sensitivity, specificity, PPV and NPV of the scan at Tt were 46%, 96%, 85% et 78%. The same parameters were 75%, 66%, 53% and 84% for the scan realized at T 0 . The joint scan has showed 22% of false positive. These false positives could be a consequence of an earlier detection of joint alterations by scan. The joint scan should forecast the evolution of joints in patients with rheumatoid arthritis. (author)

  20. Scanning gamma camera

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  1. A nanoscale gigahertz source realized with Josephson scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jäck, Berthold, E-mail: b.jaeck@fkf.mpg.de; Eltschka, Matthias; Assig, Maximilian; Etzkorn, Markus; Ast, Christian R. [Max-Planck-Institut für Festkörperforschung, 70569 Stuttgart (Germany); Hardock, Andreas [Institut für Theoretische Elektrotechnik, Technische Universität Hamburg-Harburg, 21079 Hamburg (Germany); Kern, Klaus [Max-Planck-Institut für Festkörperforschung, 70569 Stuttgart (Germany); Institut de Physique de la Matière Condensée, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne (Switzerland)

    2015-01-05

    Using the AC Josephson effect in the superconductor-vacuum-superconductor tunnel junction of a scanning tunneling microscope (STM), we demonstrate the generation of GHz radiation. With the macroscopic STM tip acting as a λ/4-monopole antenna, we first show that the atomic scale Josephson junction in the STM is sensitive to its frequency-dependent environmental impedance in the GHz regime. Further, enhancing Cooper pair tunneling via excitations of the tip eigenmodes, we are able to generate high-frequency radiation. We find that for vanadium junctions, the enhanced photon emission can be tuned from about 25 GHz to 200 GHz and that large photon flux in excess of 10{sup 20 }cm{sup −2} s{sup −1} is reached in the tunnel junction. These findings demonstrate that the atomic scale Josephson junction in an STM can be employed as a full spectroscopic tool for GHz frequencies on the atomic scale.

  2. Two-photon direct frequency comb spectroscopy of alkali atoms

    Science.gov (United States)

    Palm, Christopher; Pradhananga, Trinity; Nguyen, Khoa; Montcrieffe, Caitlin; Kimball, Derek

    2012-11-01

    We have studied transition frequencies and excited state hyperfine structure in rubidium using 2-photon transitions excited directly with the frequency-doubled output of a erbium fiber optical frequency comb. The frequency comb output is directed in two counterpropagating directions through a vapor cell containing the rubidium vapor. A pair of optical filters is used to select teeth of the comb in order to identify the transition wavelengths. A photomultiplier tube (PMT) measures fluorescence from a decay channel wavelength selected with another optical filter. Using different combinations of filters enables a wide range of transitions to be investigated. By scanning the repetition rate, a Doppler-free spectrum can be obtained enabling kHz-resolution spectral measurements. An interesting dependence of the 2-photon spectrum on the energy of the intermediate state of the 2-photon transition is discussed. Our investigations are laying the groundwork for a long-term research program to use direct frequency comb spectroscopy to understand the complex spectra of rare-earth atoms.

  3. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1992-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in Vol. I, these sudies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described inchapters on scanning force microscopy, magnetic force microscopy, scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Togehter, the two volumes give a comprehensive account of experimental aspcets of STM. They provide essentialreading and reference material for all students and researchers involvedin this field.

  4. CT Scan

    Science.gov (United States)

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  5. Renal scan

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003790.htm Renal scan To use the sharing features on this ... anaphylaxis . Alternative Names Renogram; Kidney scan Images Kidney anatomy Kidney - blood and urine flow References Chernecky CC, ...

  6. Surface density mapping of natural tissue by a scanning haptic microscope (SHM).

    Science.gov (United States)

    Moriwaki, Takeshi; Oie, Tomonori; Takamizawa, Keiichi; Murayama, Yoshinobu; Fukuda, Toru; Omata, Sadao; Nakayama, Yasuhide

    2013-02-01

    To expand the performance capacity of the scanning haptic microscope (SHM) beyond surface mapping microscopy of elastic modulus or topography, surface density mapping of a natural tissue was performed by applying a measurement theory of SHM, in which a frequency change occurs upon contact of the sample surface with the SHM sensor - a microtactile sensor (MTS) that vibrates at a pre-determined constant oscillation frequency. This change was mainly stiffness-dependent at a low oscillation frequency and density-dependent at a high oscillation frequency. Two paragon examples with extremely different densities but similar macroscopic elastic moduli in the range of natural soft tissues were selected: one was agar hydrogels and the other silicon organogels with extremely low (less than 25 mg/cm(3)) and high densities (ca. 1300 mg/cm(3)), respectively. Measurements were performed in saline solution near the second-order resonance frequency, which led to the elastic modulus, and near the third-order resonance frequency. There was little difference in the frequency changes between the two resonance frequencies in agar gels. In contrast, in silicone gels, a large frequency change by MTS contact was observed near the third-order resonance frequency, indicating that the frequency change near the third-order resonance frequency reflected changes in both density and elastic modulus. Therefore, a density image of the canine aortic wall was subsequently obtained by subtracting the image observed near the second-order resonance frequency from that near the third-order resonance frequency. The elastin-rich region had a higher density than the collagen-rich region.

  7. Sub-Airy Confocal Adaptive Optics Scanning Ophthalmoscopy.

    Science.gov (United States)

    Sredar, Nripun; Fagbemi, Oladipo E; Dubra, Alfredo

    2018-04-01

    To demonstrate the viability of improving transverse image resolution in reflectance scanning adaptive optics ophthalmoscopy using sub-Airy disk confocal detection. The foveal cone mosaic was imaged in five human subjects free of known eye disease using two custom adaptive optics scanning light ophthalmoscopes (AOSLOs) in reflectance with 7.75 and 4.30 mm pupil diameters. Confocal pinholes of 0.5, 0.6, 0.8, and 1.0 Airy disk diameters (ADDs) were used in a retinal conjugate plane before the light detector. Average cone photoreceptor intensity profile width and power spectrum were calculated for the resulting images. Detected energy using a model eye was recorded for each pinhole size. The cone photoreceptor mosaic is better resolved with decreasing confocal pinhole size, with the high spatial frequency content of the images enhanced in both the large- and small-pupil AOSLOs. The average cone intensity profile width was reduced by ∼15% with the use of a 0.5 ADD pinhole when compared to a 1.0 ADD, with an accompanying reduction in signal greater than a factor of four. The use of sub-Airy disk confocal pinhole detection without increasing retinal light exposure results in a substantial improvement in image resolution at the cost of larger than predicted signal reduction. Improvement in transverse resolution using sub-Airy disk confocal detection is a practical and low-cost approach that is applicable to all point- and line-scanning ophthalmoscopes, including optical coherence tomographers.

  8. A Space-Frequency Data Compression Method for Spatially Dense Laser Doppler Vibrometer Measurements

    Directory of Open Access Journals (Sweden)

    José Roberto de França Arruda

    1996-01-01

    Full Text Available When spatially dense mobility shapes are measured with scanning laser Doppler vibrometers, it is often impractical to use phase-separation modal parameter estimation methods due to the excessive number of highly coupled modes and to the prohibitive computational cost of processing huge amounts of data. To deal with this problem, a data compression method using Chebychev polynomial approximation in the frequency domain and two-dimensional discrete Fourier series approximation in the spatial domain, is proposed in this article. The proposed space-frequency regressive approach was implemented and verified using a numerical simulation of a free-free-free-free suspended rectangular aluminum plate. To make the simulation more realistic, the mobility shapes were synthesized by modal superposition using mode shapes obtained experimentally with a scanning laser Doppler vibrometer. A reduced and smoothed model, which takes advantage of the sinusoidal spatial pattern of structural mobility shapes and the polynomial frequency-domain pattern of the mobility shapes, is obtained. From the reduced model, smoothed curves with any desired frequency and spatial resolution can he produced whenever necessary. The procedure can he used either to generate nonmodal models or to compress the measured data prior to modal parameter extraction.

  9. Quantitative subsurface analysis using frequency modulated thermal wave imaging

    Science.gov (United States)

    Subhani, S. K.; Suresh, B.; Ghali, V. S.

    2018-01-01

    Quantitative depth analysis of the anomaly with an enhanced depth resolution is a challenging task towards the estimation of depth of the subsurface anomaly using thermography. Frequency modulated thermal wave imaging introduced earlier provides a complete depth scanning of the object by stimulating it with a suitable band of frequencies and further analyzing the subsequent thermal response using a suitable post processing approach to resolve subsurface details. But conventional Fourier transform based methods used for post processing unscramble the frequencies with a limited frequency resolution and contribute for a finite depth resolution. Spectral zooming provided by chirp z transform facilitates enhanced frequency resolution which can further improves the depth resolution to axially explore finest subsurface features. Quantitative depth analysis with this augmented depth resolution is proposed to provide a closest estimate to the actual depth of subsurface anomaly. This manuscript experimentally validates this enhanced depth resolution using non stationary thermal wave imaging and offers an ever first and unique solution for quantitative depth estimation in frequency modulated thermal wave imaging.

  10. A novel fast-scanning microwave heterodyne radiometer system for electron cyclotron emission measurements in the HT-7 superconducting tokamak

    International Nuclear Information System (INIS)

    Zhang, S.Y.; Wan, Y.X.; Xie, J.K.; Luo, J.R.; Li, J.G.; Kuang, G.L.; Gao, X.; Zhang, X.D.; Wan, B.N.; Wang, K.J.; Mao, J.S.; Gong, X.Z.; Qin, P.J.

    2000-01-01

    Two sets of fast-scanning microwave heterodyne radiometer receiver systems employing backward-wave oscillators in the 78-118 GHz and 118-178 GHz ranges were developed for electron cyclotron emission measurements (ECE) on the HT-7 superconducting tokamak. The double-sideband radiometer in the 78-118 GHz range measures 16 ECE frequency points with a scanning period of 0.65 ms. The novel design of the 2 mm fast-scanning heterodyne radiometer in the 118-178 GHz range enables the unique system to measure 48 ECE frequency points in 0.65 ms periodically. The plasma profile consistency in reproducible ohmic plasmas was used to relatively calibrate each channel by changing the toroidal magnetic field shot-by-shot. The absolute temperature value was obtained by a comparison with the results from the soft x-ray pulse height analysis measurements and Thomson scattering system. A preliminary temperature profile measurement result in pellet injection plasma is presented. (author)

  11. Damage Detection on Thin-walled Structures Utilizing Laser Scanning and Standing Waves

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Se Hyeok; Jeon, Jun Young; Kim, Du Hwan; Park, Gyuhae [Chonnam Nat’l Univ., Gwangju (Korea, Republic of); Kang, To; Han, Soon Woo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-05-15

    This paper describes wavenumber filtering for damage detection using single-frequency standing wave excitation and laser scanning sensing. An embedded piezoelectric sensor generates ultrasonic standing waves, and the responses are measured using a laser Doppler vibrometer and mirror tilting device. After scanning, newly developed damage detection techniques based on wavenumber filtering are applied to the full standing wave field. To demonstrate the performance of the proposed techniques, several experiments were performed on composite plates with delamination and aluminum plates with corrosion damage. The results demonstrated that the developed techniques could be applied to various structures to localize the damage, with the potential to improve the damage detection capability at a high interrogation speed.

  12. Fine Metal Mask 3-Dimensional Measurement by using Scanning Digital Holographic Microscope

    Science.gov (United States)

    Shin, Sanghoon; Yu, Younghun

    2018-04-01

    For three-dimensional microscopy, fast and high axial resolution are very important. Extending the depth of field for digital holographic is necessary for three-dimensional measurements of thick samples. We propose an optical sectioning method for optical scanning digital holography that is performed in the frequency domain by spatial filtering of a reconstructed amplitude image. We established a scanning dual-wavelength off-axis digital holographic microscope to measure samples that exhibit a large amount of coherent noise and a thickness larger than the depth of focus of the objective lens. As a demonstration, we performed a three-dimensional measurement of a fine metal mask with a reconstructed sectional phase image and filtering with a reconstructed amplitude image.

  13. Construction of a four tip scanning tunneling microscope/scanning electron microscope combination and conductivity measurements of silicide nanowires

    International Nuclear Information System (INIS)

    Zubkov, Evgeniy

    2013-01-01

    In this work the combination of a four-tip scanning tunneling microscope with a scanning electron microscope is presented. By means of this apparatus it is possible to perform the conductivity measurements on the in-situ prepared nanostructures in ultra-high vacuum. With the aid of a scanning electron microscope (SEM), it becomes possible to position the tunneling tips of the four-tip scanning tunneling microscope (STM), so that an arrangement for a four-point probe measurement on nanostructures can be obtained. The STM head was built according to the novel coaxial Beetle concept. This concept allows on the one hand, a very compact arrangement of the components of the STM and on the other hand, the new-built STM head has a good mechanical stability, in order to achieve atomic resolution with all four STM units. The atomic resolution of the STM units was confirmed by scanning a Si(111)-7 x 7 surface. The thermal drift during the STM operation, as well as the resonant frequencies of the mechanical structure of the STM head, were determined. The scanning electron microscope allows the precise and safe navigation of the tunneling tips on the sample surface. Multi tip spectroscopy with up to four STM units can be performed synchronously. To demonstrate the capabilities of the new-built apparatus the conductivity measurements were carried out on metallic yttrium silicide nanowires. The nanowires were prepared by the in-situ deposition of yttrium on a heated Si(110) sample surface. Current-voltage curves were recorded on the nanowires and on the wetting layer in-between. The curves indicate an existence of the Schottky barrier between the yttrium silicide nanowires and the silicon bulk. By means of the two-tip measurements with a gate, the insulating property of the Schottky barrier has been confirmed. Using this Schottky barrier, it is possible to limit the current to the nanowire and to prevent it from flowing through the silicon bulk. A four-tip resistance measurement

  14. Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

    International Nuclear Information System (INIS)

    Shibata, Koichi; Notohara, Daisuke; Sakai, Takihito

    2014-01-01

    Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the

  15. Parallel-scanning tomosynthesis using a slot scanning technique: fixed-focus reconstruction and the resulting image quality.

    Science.gov (United States)

    Shibata, Koichi; Notohara, Daisuke; Sakai, Takihito

    2014-11-01

    Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)-(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of -100, -50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the distance from the IFP increased. A

  16. Parallel-scanning tomosynthesis using a slot scanning technique: Fixed-focus reconstruction and the resulting image quality

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Koichi, E-mail: shibatak@suzuka-u.ac.jp [Department of Radiological Technology, Faculty of Health Science, Suzuka University of Medical Science 1001-1, Kishioka-cho, Suzuka 510-0293 (Japan); Notohara, Daisuke; Sakai, Takihito [R and D Department, Medical Systems Division, Shimadzu Corporation 1, Nishinokyo-Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511 (Japan)

    2014-11-01

    Purpose: Parallel-scanning tomosynthesis (PS-TS) is a novel technique that fuses the slot scanning technique and the conventional tomosynthesis (TS) technique. This approach allows one to obtain long-view tomosynthesis images in addition to normally sized tomosynthesis images, even when using a system that has no linear tomographic scanning function. The reconstruction technique and an evaluation of the resulting image quality for PS-TS are described in this paper. Methods: The PS-TS image-reconstruction technique consists of several steps (1) the projection images are divided into strips, (2) the strips are stitched together to construct images corresponding to the reconstruction plane, (3) the stitched images are filtered, and (4) the filtered stitched images are back-projected. In the case of PS-TS using the fixed-focus reconstruction method (PS-TS-F), one set of stitched images is used for the reconstruction planes at all heights, thus avoiding the necessity of repeating steps (1)–(3). A physical evaluation of the image quality of PS-TS-F compared with that of the conventional linear TS was performed using a R/F table (Sonialvision safire, Shimadzu Corp., Kyoto, Japan). The tomographic plane with the best theoretical spatial resolution (the in-focus plane, IFP) was set at a height of 100 mm from the table top by adjusting the reconstruction program. First, the spatial frequency response was evaluated at heights of −100, −50, 0, 50, 100, and 150 mm from the IFP using the edge of a 0.3-mm-thick copper plate. Second, the spatial resolution at each height was visually evaluated using an x-ray test pattern (Model No. 38, PTW Freiburg, Germany). Third, the slice sensitivity at each height was evaluated via the wire method using a 0.1-mm-diameter tungsten wire. Phantom studies using a knee phantom and a whole-body phantom were also performed. Results: The spatial frequency response of PS-TS-F yielded the best results at the IFP and degraded slightly as the

  17. The rf sigmameter: A digital phase-locked technique for accurate long-range laser scanning

    International Nuclear Information System (INIS)

    Zhu, M.; Hall, J.L.

    1986-01-01

    The authors use a new version of a sigmameter, the two-channel field-widened rf sigmameter, to map optical frequency into the phase of an rf signal. This enables them to lock the laser frequency on the interferometer by using a phase-locked loop (PLL). Controlling the reference phase of the PLL electronically, they are able to scan the laser frequency over a long range step by step or with substeps. The systematic error of each substep is cancelled automatically when the authors change one step (which is ten substeps, for example), and that of each step is cancelled when they change the reference phase by 2π (which corresponds to 256 steps in their scheme)

  18. Ultrafast scanning tunneling microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Botkin, D.A. [California Univ., Berkeley, CA (United States). Dept. of Physics]|[Lawrence Berkeley Lab., CA (United States)

    1995-09-01

    I have developed an ultrafast scanning tunneling microscope (USTM) based on uniting stroboscopic methods of ultrafast optics and scanned probe microscopy to obtain nanometer spatial resolution and sub-picosecond temporal resolution. USTM increases the achievable time resolution of a STM by more than 6 orders of magnitude; this should enable exploration of mesoscopic and nanometer size systems on time scales corresponding to the period or decay of fundamental excitations. USTM consists of a photoconductive switch with subpicosecond response time in series with the tip of a STM. An optical pulse from a modelocked laser activates the switch to create a gate for the tunneling current, while a second laser pulse on the sample initiates a dynamic process which affects the tunneling current. By sending a large sequence of identical pulse pairs and measuring the average tunnel current as a function of the relative time delay between the pulses in each pair, one can map the time evolution of the surface process. USTM was used to measure the broadband response of the STM`s atomic size tunnel barrier in frequencies from tens to hundreds of GHz. The USTM signal amplitude decays linearly with the tunnel junction conductance, so the spatial resolution of the time-resolved signal is comparable to that of a conventional STM. Geometrical capacitance of the junction does not appear to play an important role in the measurement, but a capacitive effect intimately related to tunneling contributes to the measured signals and may limit the ultimate resolution of the USTM.

  19. Scanning capacitance microscope as a tool for the characterization of integrated circuits

    Science.gov (United States)

    Born, A.; Wiesendanger, R.

    With the decreasing size of integrated circuits (ICs), there is an increasing demand for the measurement of doping profiles with high spatial resolution. The scanning capacitance microscope (SCM) offers the possibility of measuring 2D dopant profiles with spatial resolution of less than 20 nm. A great problem of the SCM technique is the influence of previous measurements on subsequent ones. We have observed hysteresis in the SCM images and measured low-frequency C-V curves with high-frequency equipment. A theoretical model was developed to understand this phenomenon. We are now undertaking the first steps using the SCM as a standard device for the characterization of ICs.

  20. Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates.

    Science.gov (United States)

    Zhang, Hao; Li, Xianqi; Chen, Yunmei; Park, Jewook; Li, An-Ping; Zhang, X-G

    2017-01-01

    We present an image postprocessing framework for Scanning Tunneling Microscope (STM) to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a "rubber band" model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA). The numerical results on measurement from copper(111) surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

  1. Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates

    Directory of Open Access Journals (Sweden)

    Hao Zhang

    2017-01-01

    Full Text Available We present an image postprocessing framework for Scanning Tunneling Microscope (STM to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a “rubber band” model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA. The numerical results on measurement from copper(111 surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

  2. Robust frequency diversity based algorithm for clutter noise reduction of ultrasonic signals using multiple sub-spectrum phase coherence

    Energy Technology Data Exchange (ETDEWEB)

    Gongzhang, R.; Xiao, B.; Lardner, T.; Gachagan, A. [Centre for Ultrasonic Engineering, University of Strathclyde, Glasgow, G1 1XW (United Kingdom); Li, M. [School of Engineering, University of Glasgow, Glasgow, G12 8QQ (United Kingdom)

    2014-02-18

    This paper presents a robust frequency diversity based algorithm for clutter reduction in ultrasonic A-scan waveforms. The performance of conventional spectral-temporal techniques like Split Spectrum Processing (SSP) is highly dependent on the parameter selection, especially when the signal to noise ratio (SNR) is low. Although spatial beamforming offers noise reduction with less sensitivity to parameter variation, phased array techniques are not always available. The proposed algorithm first selects an ascending series of frequency bands. A signal is reconstructed for each selected band in which a defect is present when all frequency components are in uniform sign. Combining all reconstructed signals through averaging gives a probability profile of potential defect position. To facilitate data collection and validate the proposed algorithm, Full Matrix Capture is applied on the austenitic steel and high nickel alloy (HNA) samples with 5MHz transducer arrays. When processing A-scan signals with unrefined parameters, the proposed algorithm enhances SNR by 20dB for both samples and consequently, defects are more visible in B-scan images created from the large amount of A-scan traces. Importantly, the proposed algorithm is considered robust, while SSP is shown to fail on the austenitic steel data and achieves less SNR enhancement on the HNA data.

  3. WOx cluster formation in radio frequency assisted pulsed laser deposition

    International Nuclear Information System (INIS)

    Filipescu, M.; Ossi, P.M.; Dinescu, M.

    2007-01-01

    The influence of oxygen gas pressure and radio-frequency power on the characteristics of the WO x films produced by laser ablation of a W target at room temperature in oxygen reactive atmosphere were investigated. Changing buffer gas pressure in the hundreds of Pa range affects the bond coordination, roughness and morphology of the deposited films, as investigated by micro-Raman spectroscopy, atomic force microscopy and scanning electron microscopy. The combination of radio-frequency discharge and buffer gas pressure on film nanostructure, as reflected by bond coordination, surface morphology and roughness is discussed

  4. Scanning probe lithography for fabrication of Ti metal nanodot arrays

    International Nuclear Information System (INIS)

    Jung, B.; Jo, W.; Gwon, M.J.; Lee, E.; Kim, D.-W.

    2010-01-01

    We report fabrication of Ti metal nanodot arrays by scanning probe microscopic indentation. A thin poly-methylmethacrylate (PMMA) layer was spin-coated on Si substrates with thickness of 70 nm. Nanometer-size pore arrays were formed by indenting the PMMA layer using a cantilever of a scanning probe microscope. Protuberances with irregular boundaries appeared during the indentation process. Control of approach and pulling-out speed during indentation was able to dispose of the protrusions. Ti metal films were deposited on the patterned PMMA layers by a radio-frequency sputtering method and subsequently lifted off to obtain metal nanodot arrays. The fabricated metal nanodot arrays have 200 nm of diameter and 500 nm of interdistance, which corresponds to a density of 4x10 8 /cm 2 . Scanning probe-based measurement of current-voltage (I-V) behaviors for a single Ti metal nanodot showed asymmetric characteristics. Applying external bias is likely to induce oxidation of Ti metal, since the conductance decreased and volume change of the dots was observed. I-V behaviors of Ti metal nanodots by conventional e-beam lithography were also characterized for comparison.

  5. A Frequency Splitting Method For CFM Imaging

    DEFF Research Database (Denmark)

    Udesen, Jesper; Gran, Fredrik; Jensen, Jørgen Arendt

    2006-01-01

    The performance of conventional CFM imaging will often be degraded due to the relatively low number of pulses (4-10) used for each velocity estimate. To circumvent this problem we propose a new method using frequency splitting (FS). The FS method uses broad band chirps as excitation pulses instead...... of narrow band pulses as in conventional CFM imaging. By appropriate filtration, the returned signals are divided into a number of narrow band signals which are approximately disjoint. After clutter filtering the velocities are found from each frequency band using a conventional autocorrelation estimator......, a 5 MHz linear array transducer was used to scan a vessel situated at 30 mm depth with a maximum flow velocity of 0.1 m/s. The pulse repetition frequency was 1.8 kHz and the angle between the flow and the beam was 60 deg. A 15 mus chirp was used as excitation pulse and 40 independent velocity...

  6. Scanning tunneling microscopy II further applications and related scanning techniques

    CERN Document Server

    Güntherodt, Hans-Joachim

    1995-01-01

    Scanning Tunneling Microscopy II, like its predecessor, presents detailed and comprehensive accounts of the basic principles and broad range of applications of STM and related scanning probe techniques. The applications discussed in this volume come predominantly from the fields of electrochemistry and biology. In contrast to those described in STM I, these studies may be performed in air and in liquids. The extensions of the basic technique to map other interactions are described in chapters on scanning force microscopy, magnetic force microscopy, and scanning near-field optical microscopy, together with a survey of other related techniques. Also described here is the use of a scanning proximal probe for surface modification. Together, the two volumes give a comprehensive account of experimental aspects of STM. They provide essential reading and reference material for all students and researchers involved in this field. In this second edition the text has been updated and new methods are discussed.

  7. Precision improvement of frequency-modulated continuous-wave laser ranging system with two auxiliary interferometers

    Science.gov (United States)

    Shi, Guang; Wang, Wen; Zhang, Fumin

    2018-03-01

    The measurement precision of frequency-modulated continuous-wave (FMCW) laser distance measurement should be proportional to the scanning range of the tunable laser. However, the commercial external cavity diode laser (ECDL) is not an ideal tunable laser source in practical applications. Due to the unavoidable mode hopping and scanning nonlinearity of the ECDL, the measurement precision of FMCW laser distance measurements can be substantially affected. Therefore, an FMCW laser ranging system with two auxiliary interferometers is proposed in this paper. Moreover, to eliminate the effects of ECDL, the frequency-sampling method and mode hopping influence suppression method are employed. Compared with a fringe counting interferometer, this FMCW laser ranging system has a measuring error of ± 20 μm at the distance of 5.8 m.

  8. Cooperative scans

    NARCIS (Netherlands)

    M. Zukowski (Marcin); P.A. Boncz (Peter); M.L. Kersten (Martin)

    2004-01-01

    textabstractData mining, information retrieval and other application areas exhibit a query load with multiple concurrent queries touching a large fraction of a relation. This leads to individual query plans based on a table scan or large index scan. The implementation of this access path in most

  9. The heat capacity of polyethylene fibers measured by multi-frequency temperature-modulated calorimetry

    International Nuclear Information System (INIS)

    Pyda, M.; Nowak-Pyda, E.; Wunderlich, B.

    2006-01-01

    The apparent heat capacity of polyethylene fibers in the melting region was measured by quasi-isothermal, temperature-modulated differential scanning calorimetry (TMDSC) and compared with results from standard differential scanning calorimetry (DSC) and the solid and liquid thermodynamic heat capacity as references from the ATHAS Data Bank. Using a multi-frequency, complex sawtooth modulation in the quasi-isothermal mode disclosed for the first time that the uncorrected apparent heat capacity C p =A Φ /(A T s ω) of the liquid polyethylene fiber increases with increasing frequency (A Φ is the differential heat-flow rate and A T s is the sample temperature). The frequency-dependent heat capacity cannot be represented by the expression: C p =A Φ /(A T s νω)[1+(τνω) 2 ] 0.5 because of a negative τ 2 . The results were later confirmed by independent measurements on single sinusoidal quasi-isothermal TMDSC on the same material. The error is caused by shrinking of the fiber, which deforms the sample pan

  10. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled XY and Z Scans.

    Science.gov (United States)

    Chen, Xu; Guo, Tengfei; Hou, Yubin; Zhang, Jing; Meng, Wenjie; Lu, Qingyou

    2017-01-01

    A new scan-head structure for the scanning tunneling microscope (STM) is proposed, featuring high scan precision and rigidity. The core structure consists of a piezoelectric tube scanner of quadrant type (for XY scans) coaxially housed in a piezoelectric tube with single inner and outer electrodes (for Z scan). They are fixed at one end (called common end). A hollow tantalum shaft is coaxially housed in the XY -scan tube and they are mutually fixed at both ends. When the XY scanner scans, its free end will bring the shaft to scan and the tip which is coaxially inserted in the shaft at the common end will scan a smaller area if the tip protrudes short enough from the common end. The decoupled XY and Z scans are desired for less image distortion and the mechanically reduced scan range has the superiority of reducing the impact of the background electronic noise on the scanner and enhancing the tip positioning precision. High quality atomic resolution images are also shown.

  11. A High Rigidity and Precision Scanning Tunneling Microscope with Decoupled XY and Z Scans

    Directory of Open Access Journals (Sweden)

    Xu Chen

    2017-01-01

    Full Text Available A new scan-head structure for the scanning tunneling microscope (STM is proposed, featuring high scan precision and rigidity. The core structure consists of a piezoelectric tube scanner of quadrant type (for XY scans coaxially housed in a piezoelectric tube with single inner and outer electrodes (for Z scan. They are fixed at one end (called common end. A hollow tantalum shaft is coaxially housed in the XY-scan tube and they are mutually fixed at both ends. When the XY scanner scans, its free end will bring the shaft to scan and the tip which is coaxially inserted in the shaft at the common end will scan a smaller area if the tip protrudes short enough from the common end. The decoupled XY and Z scans are desired for less image distortion and the mechanically reduced scan range has the superiority of reducing the impact of the background electronic noise on the scanner and enhancing the tip positioning precision. High quality atomic resolution images are also shown.

  12. Special raster scanning for reduction of charging effects in scanning electron microscopy.

    Science.gov (United States)

    Suzuki, Kazuhiko; Oho, Eisaku

    2014-01-01

    A special raster scanning (SRS) method for reduction of charging effects is developed for the field of SEM. Both a conventional fast scan (horizontal direction) and an unusual scan (vertical direction) are adopted for acquiring raw data consisting of many sub-images. These data are converted to a proper SEM image using digital image processing techniques. About sharpness of the image and reduction of charging effects, the SRS is compared with the conventional fast scan (with frame-averaging) and the conventional slow scan. Experimental results show the effectiveness of SRS images. By a successful combination of the proposed scanning method and low accelerating voltage (LV)-SEMs, it is expected that higher-quality SEM images can be more easily acquired by the considerable reduction of charging effects, while maintaining the resolution. © 2013 Wiley Periodicals, Inc.

  13. Ultra compact multitip scanning tunneling microscope with a diameter of 50 mm.

    Science.gov (United States)

    Cherepanov, Vasily; Zubkov, Evgeny; Junker, Hubertus; Korte, Stefan; Blab, Marcus; Coenen, Peter; Voigtländer, Bert

    2012-03-01

    We present a multitip scanning tunneling microscope (STM) where four independent STM units are integrated on a diameter of 50 mm. The coarse positioning of the tips is done under the control of an optical microscope or scanning electron microscopy in vacuum. The heart of this STM is a new type of piezoelectric coarse approach called KoalaDrive. The compactness of the KoalaDrive allows building a four-tip STM as small as a single-tip STM with a drift of less than 0.2 nm/min at room temperature and lowest resonance frequencies of 2.5 kHz (xy) and 5.5 kHz (z). We present as examples of the performance of the multitip STM four point measurements of silicide nanowires and graphene.

  14. Scan path entropy and Arrow plots: Capturing scanning behavior of multiple observers

    Directory of Open Access Journals (Sweden)

    Ignace T C Hooge

    2013-12-01

    Full Text Available Designers of visual communication material want their material to attract and retain attention. In marketing research, heat maps, dwell time, and time to AOI first hit are often used as evaluation parameters. Here we present two additional measures 1 scan path entropy to quantify gaze guidance and 2 the arrow plot to visualize the average scan path. Both are based on string representations of scan paths. The latter also incorporates transition matrices and time required for 50% of the observers to first hit AOIs (T50. The new measures were tested in an eye tracking study (48 observers, 39 advertisements. Scan path entropy is a sensible measure for gaze guidance and the new visualization method reveals aspects of the average scan path and gives a better indication in what order global scanning takes place.

  15. Scanning Tunneling Optical Resonance Microscopy

    Science.gov (United States)

    Bailey, Sheila; Wilt, Dave; Raffaelle, Ryne; Gennett, Tom; Tin, Padetha; Lau, Janice; Castro, Stephanie; Jenkins, Philip; Scheiman, Dave

    2003-01-01

    Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically tunneling current

  16. Research on Method of Photoelectric Measurement for Tilt Angle of Scanning Mirror of Infrared Earth Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Xu, X P; Zhang, G Y; Zhang, N; Wang, L Y [Changchun University of Science and Technology, 130022, Changchun (China)

    2006-10-15

    Tilt angle of scanning mirror is one of the important qualifications of performance measurement on the earth surface for swing scanning mode infrared the earth sensor. In order to settle the problem of measuring the tilt angle of scanning mirror in dynamic, real-time and non-contact, based on laser inspecting technology and CCD probing technology, a method of laser dynamical measurement for tilt angle of scanning mirror of the infrared earth sensor is presented. The measurement system developed in this paper can accomplish the dynamic and static laser non-contact measurement for the parameters of scanning mirror such as tilt angle, swing frequency, etc. In this paper the composition and overall structure of system are introduced. Emphasis on analyzing and discussing the theory of dynamically measuring tilt angle of scanning mirror, the problems of data processing and error correction are settled by established mathematic model of system. The accuracy of measurement system is verified by experiment, the results indicated that measurement range of system for tilt angle is 0{approx}{+-}12{sup 0}, accuracy of dynamic and static measurement is less than {+-}0.05{sup 0}, this method of dynamically measuring tilt angle is suitable.

  17. A quantitative damage imaging technique based on enhanced CCRTM for composite plates using 2D scan

    Science.gov (United States)

    He, Jiaze; Yuan, Fuh-Gwo

    2016-10-01

    A two-dimensional (2D) non-contact areal scan system was developed to image and quantify impact damage in a composite plate using an enhanced zero-lag cross-correlation reverse-time migration (E-CCRTM) technique. The system comprises a single piezoelectric wafer mounted on the composite plate and a laser Doppler vibrometer (LDV) for scanning a region in the vicinity of the PZT to capture the scattered wavefield. The proposed damage imaging technique takes into account the amplitude, phase, geometric spreading, and all of the frequency content of the Lamb waves propagating in the plate; thus, a reflectivity coefficients of the delamination is calculated and potentially related to damage severity. Comparisons are made in terms of damage imaging quality between 2D areal scans and 1D line scans as well as between the proposed and existing imaging conditions. The experimental results show that the 2D E-CCRTM performs robustly when imaging and quantifying impact damage in large-scale composites using a single PZT actuator with a nearby areal scan using LDV.

  18. Optimization of the imaging response of scanning microwave microscopy measurements

    Energy Technology Data Exchange (ETDEWEB)

    Sardi, G. M.; Lucibello, A.; Proietti, E.; Marcelli, R., E-mail: romolo.marcelli@imm.cnr.it [National Research Council, Institute for Microelectronics and Microsystems, Via del Fosso del Cavaliere 100, 00133 Rome (Italy); Kasper, M.; Gramse, G. [Biophysics Institute, Johannes Kepler University, Gruberstrasse 40, 4020 Linz (Austria); Kienberger, F. [Keysight Technologies Austria GmbH, Gruberstrasse 40, 4020 Linz (Austria)

    2015-07-20

    In this work, we present the analytical modeling and preliminary experimental results for the choice of the optimal frequencies when performing amplitude and phase measurements with a scanning microwave microscope. In particular, the analysis is related to the reflection mode operation of the instrument, i.e., the acquisition of the complex reflection coefficient data, usually referred as S{sub 11}. The studied configuration is composed of an atomic force microscope with a microwave matched nanometric cantilever probe tip, connected by a λ/2 coaxial cable resonator to a vector network analyzer. The set-up is provided by Keysight Technologies. As a peculiar result, the optimal frequencies, where the maximum sensitivity is achieved, are different for the amplitude and for the phase signals. The analysis is focused on measurements of dielectric samples, like semiconductor devices, textile pieces, and biological specimens.

  19. Adaptive and robust statistical methods for processing near-field scanning microwave microscopy images.

    Science.gov (United States)

    Coakley, K J; Imtiaz, A; Wallis, T M; Weber, J C; Berweger, S; Kabos, P

    2015-03-01

    Near-field scanning microwave microscopy offers great potential to facilitate characterization, development and modeling of materials. By acquiring microwave images at multiple frequencies and amplitudes (along with the other modalities) one can study material and device physics at different lateral and depth scales. Images are typically noisy and contaminated by artifacts that can vary from scan line to scan line and planar-like trends due to sample tilt errors. Here, we level images based on an estimate of a smooth 2-d trend determined with a robust implementation of a local regression method. In this robust approach, features and outliers which are not due to the trend are automatically downweighted. We denoise images with the Adaptive Weights Smoothing method. This method smooths out additive noise while preserving edge-like features in images. We demonstrate the feasibility of our methods on topography images and microwave |S11| images. For one challenging test case, we demonstrate that our method outperforms alternative methods from the scanning probe microscopy data analysis software package Gwyddion. Our methods should be useful for massive image data sets where manual selection of landmarks or image subsets by a user is impractical. Published by Elsevier B.V.

  20. Near-field microwave magnetic nanoscopy of superconducting radio frequency cavity materials

    Science.gov (United States)

    Tai, Tamin; Ghamsari, Behnood G.; Bieler, Thomas R.; Tan, Teng; Xi, X. X.; Anlage, Steven M.

    2014-06-01

    A localized measurement of the RF critical field on superconducting radio frequency (SRF) cavity materials is a key step to identify specific defects that produce quenches of SRF cavities. Two measurements are performed to demonstrate these capabilities with a near-field scanning probe microwave microscope. The first is a third harmonic nonlinear measurement on a high Residual-Resistance-Ratio bulk Nb sample showing strong localized nonlinear response, with surface RF magnetic field Bsurface˜102 mT. The second is a raster scanned harmonic response image on a MgB2 thin film demonstrating a uniform nonlinear response over large areas.

  1. EchoScan: A new system to objectively assess peripheral hearing disorders

    Directory of Open Access Journals (Sweden)

    Thomas Venet

    2012-01-01

    Full Text Available Pure-tone air-conduction audiometry (PTA is the reference clinical test used in Europe and the United States to measure the extent of hearing loss. It is a subjective, behavioral test, which measures thresholds of hearing sensations and perceptions based on patient responses to frequency-specific pure-tone stimuli. PTA can detect hearing problems due to cochlear or retro-cochlear impairment, without identifying the source of the problem. In contrast, cubic distortion product otoacoustic emissions (DPOAEs detect inner-ear dysfunctions, particularly those involving the outer hair cells sensitive to noise and ototoxicants. Recently, ototoxicants were shown to have an action on the central nuclei driving the middle-ear acoustic reflex. Therefore, a new device, called EchoScan, was conceived to collect and measure performance both in the middle- and inner-ear. Its originality: the use of a battery of DPOAE measurements associated with contra-lateral acoustic stimulation. Changes in DPOAE amplitude due to ageing and gender were incidentally detected and EchoScan was more sensitive than impedancemetry to detect the stapedial reflex. EchoScan can be used both in clinical investigations and in occupational medicine, especially for the auditory follow-up of people exposed to noise or ototoxic agents. EchoScan could be promising to assess early detection in programs to prevent hearing loss.

  2. Multi-distance diffuse optical spectroscopy with a single optode via hypotrochoidal scanning.

    Science.gov (United States)

    Applegate, Matthew B; Roblyer, Darren

    2018-02-15

    Frequency-domain diffuse optical spectroscopy (FD-DOS) is an established technique capable of determining optical properties and chromophore concentrations in biological tissue. Most FD-DOS systems use either manually positioned, handheld probes or complex arrays of source and detector fibers to acquire data from many tissue locations, allowing for the generation of 2D or 3D maps of tissue. Here, we present a new method to rapidly acquire a wide range of source-detector (SD) separations by mechanically scanning a single SD pair. The source and detector fibers are mounted on a scan head that traces a hypotrochoidal pattern over the sample that, when coupled with a high-speed FD-DOS system, enables the rapid collection of dozens of SD separations for depth-resolved imaging. We demonstrate that this system has an average error of 4±2.6% in absorption and 2±1.8% in scattering across all SD separations. Additionally, by linearly translating the device, the size and location of an absorbing inhomogeneity can be determined through the generation of B-scan images in a manner conceptually analogous to ultrasound imaging. This work demonstrates the potential of single optode diffuse optical scanning for depth resolved visualization of heterogeneous biological tissues at near real-time rates.

  3. Radio frequency picosecond phototube

    International Nuclear Information System (INIS)

    Margaryan, A.; Carlini, R.; Ent, R.; Grigoryan, N.; Gyunashyan, K.; Hashimoto, O.; Hovater, K.; Ispiryan, M.; Knyazyan, S.; Kross, B.; Majewski, S.; Marikyan, G.; Mkrtchyan, M.; Parlakyan, L.; Popov, V.; Tang, L.; Vardanyan, H.; Yan, C.; Zhamkochyan, S.; Zorn, C.

    2006-01-01

    We propose a photon detector for recording low-level and ultra-fast optical signals, based on radio frequency (RF) analysis of low-energy photoelectrons (PEs). By using currently developed 500 MHz RF deflector, it is possible to scan circularly and detect single PEs, amplified in multi-channel plates (MCPs). The operation of the tube is investigated by means of thermionic electron source. It is demonstrated that the signals generated in the MCP can be processed event by event; by using available nanosecond electronics and that time resolution better than 20 ps can be achieved. Timing characteristics of the Cherenkov detector with RF phototube in a 'head-on' geometry is investigated by means of Monte Carlo simulation

  4. Radio frequency picosecond phototube

    Energy Technology Data Exchange (ETDEWEB)

    Margaryan, A. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia)]. E-mail: mat@mail.yerphi.am; Carlini, R. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Ent, R. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Grigoryan, N. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Gyunashyan, K. [Yerevan State University of Architecture and Construction, Yerevan (Armenia); Hashimoto, O. [Tohoku University, Sendai 98-77 (Japan); Hovater, K. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Ispiryan, M. [University of Houston, 4800 Calhoun Rd, Houston TX 77204 (United States); Knyazyan, S. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Kross, B. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Majewski, S. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Marikyan, G. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Mkrtchyan, M. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Parlakyan, L. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Popov, V. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Tang, L. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Vardanyan, H. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Yan, C. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Zhamkochyan, S. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Zorn, C. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States)

    2006-10-15

    We propose a photon detector for recording low-level and ultra-fast optical signals, based on radio frequency (RF) analysis of low-energy photoelectrons (PEs). By using currently developed 500 MHz RF deflector, it is possible to scan circularly and detect single PEs, amplified in multi-channel plates (MCPs). The operation of the tube is investigated by means of thermionic electron source. It is demonstrated that the signals generated in the MCP can be processed event by event; by using available nanosecond electronics and that time resolution better than 20 ps can be achieved. Timing characteristics of the Cherenkov detector with RF phototube in a 'head-on' geometry is investigated by means of Monte Carlo simulation.

  5. Measurement of low-frequency noise in rooms

    DEFF Research Database (Denmark)

    Pedersen, Steffen; Møller, Henrik; Persson-Waye, Kerstin

    2006-01-01

    Measurement of low-frequency noise in rooms is problematic due to standing wave patterns. The spatial variation in the sound pressure level can typically be as much as 20-30 dB. For assessment of annoyance from low-frequency noise in dwellings, it is important to measure a level close...... rooms. The sound pressure level was measured 1) in three-dimensional corners and 2) according to current Swedish and Danish measurement methods. Furthermore, the entire sound pressure distributions were measured by scanning. The Swedish and Danish measurement methods include a corner measurement...... to the highest level present in a room, rather than a room average level. In order to ensure representative noise measurements, different positions were investigated based on theoretical considerations and observations from numerical room simulations. In addition measurements were performed in three different...

  6. LASER ABLATION OF MONOCRYSTALLINE SILICON UNDER PULSED-FREQUENCY FIBER LASER

    Directory of Open Access Journals (Sweden)

    V. P. Veiko

    2015-05-01

    Full Text Available Subject of research. The paper deals with research of the surface ablation for single-crystal silicon wafers and properties of materials obtained in response to silicon ablation while scanning beam radiation of pulse fiber ytterbium laser with a wavelenght λ = 1062 nm in view of variation of radiation power and scanning modes. Method. Wafers of commercial p-type conductivity silicon doped with boron (111, n-type conductivity silicon doped with phosphorus (100 have been under research with a layer of intrinsical silicon oxide having the thickness equal to several 10 s of nanometers and SiO2 layer thickness from 120 to 300 nm grown by thermal oxidation method. The learning system comprises pulse fiber ytterbium laser with a wavelenght λ = 1062 nm. The laser rated-power output is equal to 20 W, pulse length is 100 ns. Pulses frequency is in the range from 20 kHz to 100 kHz. Rated energy in the pulse is equal to 1.0 mJ. Scanning has been carried out by means of two axial scanning device driven by VM2500+ and controlled by personal computer with «SinMarkТМ» software package. Scanning velocity is in the range from 10 mm/s to 4000 mm/s, the covering varies from 100 lines per mm to 3000 lines per mm. Control of samples has been carried out by means of Axio Imager A1m optical microscope Carl Zeiss production with a high definition digital video camera. All experiments have been carried out in the mode of focused laser beam with a radiation spot diameter at the substrate equal to 50 μm. The change of temperature and its distribution along the surface have been evaluated by FLIR IR imager of SC7000 series. Main results. It is shown that ablation occurs without silicon melting and with plasma torch origination. The particles of ejected silicon take part in formation of silicon ions plasma and atmosphere gases supporting the plasmo-chemical growth of SiO2. The range of beam scanning modes is determined where the growth of SiO2 layer is observed

  7. Radiopharmaceutical scanning agents

    International Nuclear Information System (INIS)

    1976-01-01

    This invention is directed to dispersions useful in preparing radiopharmaceutical scanning agents, to technetium labelled dispersions, to methods for preparing such dispersions and to their use as scanning agents

  8. Nuclear Heart Scan

    Science.gov (United States)

    ... Home / Nuclear Heart Scan Nuclear Heart Scan Also known as Nuclear Stress Test , ... Learn More Connect With Us Contact Us Directly Policies Privacy Policy Freedom of Information Act (FOIA) Accessibility ...

  9. Band excitation method applicable to scanning probe microscopy

    Science.gov (United States)

    Jesse, Stephen [Knoxville, TN; Kalinin, Sergei V [Knoxville, TN

    2010-08-17

    Methods and apparatus are described for scanning probe microscopy. A method includes generating a band excitation (BE) signal having finite and predefined amplitude and phase spectrum in at least a first predefined frequency band; exciting a probe using the band excitation signal; obtaining data by measuring a response of the probe in at least a second predefined frequency band; and extracting at least one relevant dynamic parameter of the response of the probe in a predefined range including analyzing the obtained data. The BE signal can be synthesized prior to imaging (static band excitation), or adjusted at each pixel or spectroscopy step to accommodate changes in sample properties (adaptive band excitation). An apparatus includes a band excitation signal generator; a probe coupled to the band excitation signal generator; a detector coupled to the probe; and a relevant dynamic parameter extractor component coupled to the detector, the relevant dynamic parameter extractor including a processor that performs a mathematical transform selected from the group consisting of an integral transform and a discrete transform.

  10. SPATIAL REPARTITION OF CURRENT FLUCTUATIONS IN A SCANNING TUNNELING MICROSCOPE

    Directory of Open Access Journals (Sweden)

    Jerome Lagoute

    2011-05-01

    Full Text Available Scanning Tunneling Microscopy (STM is a technique where the surface topography of a conducting sample is probed by a scanning metallic tip. The tip-to-surface distance is controlled by monitoring the electronic tunneling current between the two metals. The aim of this work is to extend the temporal range of this instrument by characterising the time fluctuations of this current on different surfaces. The current noise power spectral density is dominated by a characteristic 1/f component, the physical origin of which is not yet clearly identified, despite a number of investigations. A new I-V preamplifier was developed in order to characterise these fluctuations of the tunnelling current and to obtain images of their spatial repartition. It is observed that their intensity is correlated with some topographical features. This information can be used to get insights on the physical phenomena involved that are not accessible by the usual STM set-up, which is limited to low frequencies.

  11. Theory and feasibility tests for a seismic scanning tunnelling macroscope

    KAUST Repository

    Schuster, Gerard T.

    2012-09-01

    We propose a seismic scanning tunnelling macroscope (SSTM) that can detect subwavelength scatterers in the near-field of either the source or the receivers. Analytic formulas for the time reverse mirror (TRM) profile associated with a single scatterer model show that the spatial resolution limit to be, unlike the Abbe limit of λ/2, independent of wavelength and linearly proportional to the source-scatterer separation as long as the scatterer is in the near-field region. This means that, as the scatterer approaches the source, imaging of the scatterer with super-resolution can be achieved. Acoustic and elastic simulations support this concept, and a seismic experiment in an Arizona tunnel shows a TRM profile with super-resolution adjacent to the fault location. The SSTM is analogous to the optical scanning tunnelling microscopes having subwavelength resolution. Scaled to seismic frequencies, it is theoretically possible to extract 100 Hz information from 20 Hz data by the imaging of near-field seismic energy.

  12. Multi-frequency Defect Selective Imaging via Nonlinear Ultrasound

    Science.gov (United States)

    Solodov, Igor; Busse, Gerd

    The concept of defect-selective ultrasonic nonlinear imaging is based on visualization of strongly nonlinear inclusions in the form of localized cracked defects. For intense excitation, the ultrasonic response of defects is affected by mechanical constraint between their fragments that makes their vibrations extremely nonlinear. The cracked flaws, therefore, efficiently generate multiple new frequencies, which can be used as a nonlinear "tag" to detect and image them. In this paper, the methodologies of nonlinear scanning laser vibrometry (NSLV) and nonlinear air-coupled emission (NACE) are applied for nonlinear imaging of various defects in hi-tech and constructional materials. A broad database obtained demonstrates evident advantages of the nonlinear approach over its linear counterpart. The higher-order nonlinear frequencies provide increase in signal-to-noise ratio and enhance the contrast of imaging. Unlike conventional ultrasonic instruments, the nonlinear approach yields abundant multi-frequency information on defect location. The application of image recognition and processing algorithms is described and shown to improve reliability and quality of ultrasonic imaging.

  13. Structured Light Based 3d Scanning for Specular Surface by the Combination of Gray Code and Phase Shifting

    Science.gov (United States)

    Zhang, Yujia; Yilmaz, Alper

    2016-06-01

    Surface reconstruction using coded structured light is considered one of the most reliable techniques for high-quality 3D scanning. With a calibrated projector-camera stereo system, a light pattern is projected onto the scene and imaged by the camera. Correspondences between projected and recovered patterns are computed in the decoding process, which is used to generate 3D point cloud of the surface. However, the indirect illumination effects on the surface, such as subsurface scattering and interreflections, will raise the difficulties in reconstruction. In this paper, we apply maximum min-SW gray code to reduce the indirect illumination effects of the specular surface. We also analysis the errors when comparing the maximum min-SW gray code and the conventional gray code, which justifies that the maximum min-SW gray code has significant superiority to reduce the indirect illumination effects. To achieve sub-pixel accuracy, we project high frequency sinusoidal patterns onto the scene simultaneously. But for specular surface, the high frequency patterns are susceptible to decoding errors. Incorrect decoding of high frequency patterns will result in a loss of depth resolution. Our method to resolve this problem is combining the low frequency maximum min-SW gray code and the high frequency phase shifting code, which achieves dense 3D reconstruction for specular surface. Our contributions include: (i) A complete setup of the structured light based 3D scanning system; (ii) A novel combination technique of the maximum min-SW gray code and phase shifting code. First, phase shifting decoding with sub-pixel accuracy. Then, the maximum min-SW gray code is used to resolve the ambiguity resolution. According to the experimental results and data analysis, our structured light based 3D scanning system enables high quality dense reconstruction of scenes with a small number of images. Qualitative and quantitative comparisons are performed to extract the advantages of our new

  14. Broadband frequency and angular response of a sinusoidal bull’s eye antenna

    Science.gov (United States)

    Beaskoetxea, U.; Navarro-Cía, M.; Beruete, M.

    2016-07-01

    A thorough experimental study of the frequency and beaming angle response of a metallic leaky-wave bull’s eye antenna working at 77 GHz with a sinusoidally corrugated profile is presented. The beam scanning property of these antennas as frequency is varied is experimentally demonstrated and corroborated through theoretical and numerical results. From the experimental results the dispersion diagram of the n  =  -1 and n  =  -2 space harmonics is extracted, and the operation at different frequency regimes is identified and discussed. In order to show the contribution of each half of the antenna, numerical examples of the near-field behavior are also displayed. Overall, experimental results are in good qualitative and quantitative agreement with theoretical and numerical calculations. Finally, an analysis of the beamwidth as a function of frequency is performed, showing that it can achieve values below 1.5° in a fractional bandwidth of 4% around the operation frequency, which is an interesting frequency-stable broadside radiation.

  15. RBC nuclear scan

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  16. Effect of ultrasound frequency on the Nakagami statistics of human liver tissues.

    Directory of Open Access Journals (Sweden)

    Po-Hsiang Tsui

    Full Text Available The analysis of the backscattered statistics using the Nakagami parameter is an emerging ultrasound technique for assessing hepatic steatosis and fibrosis. Previous studies indicated that the echo amplitude distribution of a normal liver follows the Rayleigh distribution (the Nakagami parameter m is close to 1. However, using different frequencies may change the backscattered statistics of normal livers. This study explored the frequency dependence of the backscattered statistics in human livers and then discussed the sources of ultrasound scattering in the liver. A total of 30 healthy participants were enrolled to undergo a standard care ultrasound examination on the liver, which is a natural model containing diffuse and coherent scatterers. The liver of each volunteer was scanned from the right intercostal view to obtain image raw data at different central frequencies ranging from 2 to 3.5 MHz. Phantoms with diffuse scatterers only were also made to perform ultrasound scanning using the same protocol for comparisons with clinical data. The Nakagami parameter-frequency correlation was evaluated using Pearson correlation analysis. The median and interquartile range of the Nakagami parameter obtained from livers was 1.00 (0.98-1.05 for 2 MHz, 0.93 (0.89-0.98 for 2.3 MHz, 0.87 (0.84-0.92 for 2.5 MHz, 0.82 (0.77-0.88 for 3.3 MHz, and 0.81 (0.76-0.88 for 3.5 MHz. The Nakagami parameter decreased with the increasing central frequency (r = -0.67, p < 0.0001. However, the effect of ultrasound frequency on the statistical distribution of the backscattered envelopes was not found in the phantom results (r = -0.147, p = 0.0727. The current results demonstrated that the backscattered statistics of normal livers is frequency-dependent. Moreover, the coherent scatterers may be the primary factor to dominate the frequency dependence of the backscattered statistics in a liver.

  17. Laser Ultrasound Spectroscopy Scanning for 3D Printed Parts

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, Guendalyn Kendra [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-04

    One of the challenges of additive manufacturing is quality control due to the possibility of unseen flaws in the final product. The current methods of inspection are lacking in detail, too slow for practical use, or unable to validate internal structure. This report examines the use of laser ultrasound spectroscopy in layer by layer scans of 3D printed parts as they are created. The result is fast and detailed quality control. An additional advantage of this method is the ability to cancel a print as soon as a defect is detected, therefore saving materials and time. This technique, though simple in concept, has been a challenge to implement. I discuss tweaking the 3D printer configuration, and finding the optimal settings for laser scanning small parts made of ABS plastic, as well as the limits of how small of a detail the laser can detect. These settings include the frequency of the ultrasonic transducer, the speed of the laser, and the distance from the laser to the part.

  18. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning, 2

    International Nuclear Information System (INIS)

    Uchiyama, Mayuki; Tanaka, Hiroshi; Harada, Junta

    1992-01-01

    Computed tomography was performed on 104 patients with cleft lip and palate by continuous 2 mm slice scanning. The type of hard palate was classified as normal, hypoplasia and aplasia, depending on its developmental degree. The shape of alveolus was also classified as circular, triangular and asymmetric forms for the evaluation of the maxillary development. The hard palate development correlated with the shape of the alveolus, the diameter of maxillary and mandibular bone, and frequency of sinusitis and otitis media. Evaluation of the hard palate by thin slice scanning is useful in presumption of future fecial development. (author)

  19. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning, 2

    Energy Technology Data Exchange (ETDEWEB)

    Uchiyama, Mayuki; Tanaka, Hiroshi; Harada, Junta (Jikei Univ., Tokyo (Japan). School of Medicine)

    1992-06-01

    Computed tomography was performed on 104 patients with cleft lip and palate by continuous 2 mm slice scanning. The type of hard palate was classified as normal, hypoplasia and aplasia, depending on its developmental degree. The shape of alveolus was also classified as circular, triangular and asymmetric forms for the evaluation of the maxillary development. The hard palate development correlated with the shape of the alveolus, the diameter of maxillary and mandibular bone, and frequency of sinusitis and otitis media. Evaluation of the hard palate by thin slice scanning is useful in presumption of future fecial development. (author).

  20. Role of B-scan ultrasonography in pre-operative cataract patients.

    Science.gov (United States)

    Qureshi, Manzoor A; Laghari, Khalida

    2010-01-01

    To visualize the posterior portion of eye globe in dense cataract patients with B scan ultrasound, and to find out any posterior segment lesion in such pre-operative cases. We performed diagnostic B-scan ultrasound on 750 cataract patients before surgery. This was a prospective diagnostic study which was conducted in the Department of Opthalmology, Liaquat University Eye Hospital, Hyderabad Sind, Pakistan from January 2007 to July 2007. Detailed history and some basic eye examination techniques, like slit lamp and tonometry were done in two groups of patients, traumatic (71) and non traumatic(679). Patients in the age range of 1 to 79 years of both sexes were included. Patients having already posterior segment lesions and those who had previous history of ocular surgery were excluded from the study. An ultrasound machine Nidek Echo Scan Model US-3300 with a probe of direct contact was used. Out of 750 patients, 90 patients had posterior segment lesions. Among traumatic group of 71 patients, 39 (55%) had positive posterior segment lesions, while in the non traumatic group of 679 patients, only 51 (7%) cases had positive posterior segment lesions. Out of the 90 positive cases, 25 (3%) had retinal detachment, 14 (2%) had posterior vitreous detachment, 24 (3%) had vitreous hemorrhage, 12 (2%) were asteroid hyolosis, while posterior staphyloma and intra-ocular foreign body were found with the frequency of 9 (1.2%) and 6 (1%), respectively. We concluded that two dimensional B-scan ultrasound can be one of the diagnostic tool for the detection of hidden posterior segment lesions and can be performed routinely in pre-operative cataract patients, as this would help in surgical planning. In cases, where a two dimensional B-scan is not sufficient or helpful. a three dimensional ultrasound would be justified.

  1. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    International Nuclear Information System (INIS)

    Tanaka, Hiroshi

    1988-01-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development. (author)

  2. Evaluation of cleft lip and palate by computed tomography with 2 mm thin slice scanning

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Hiroshi

    1988-07-01

    Computed tomography was carried out in 65 patients of cleft lip and palate with continuous 2 mm slice scanning. The cleft lip and palate was classified by shape of the hard palate as normal, hypoplasia, and aplasia, depending on its developmental degree. The shape of alveolus was also grouped as circular, triangular, and asymmetric forms for the evaluation of maxillar development. The hard palatal development well correlated with the shape of the alveolus. Frequency of sinusitis and mastoiditis increased with the severity of hard palatal malformation. Evaluation of the hard palate by thin slice scanning is usefull standpoint of presumption of future maxillary development.

  3. One-dimensional low spatial frequency LIPSS with rotating orientation on fused silica

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, Simon, E-mail: simon.schwarz@h-ab.de; Rung, Stefan; Hellmann, Ralf

    2017-07-31

    Highlights: • Generation of one-dimensional low spatial frequency LIPSS on transparent material. • Varying the angle of incidence results in a rotation of the one-dimensional LSFL. • Rotation angle of LSFL decreases with increasing the applied fluence. • Orientation of the LSFL is mirror-inverted when reversing the scanning direction. - Abstract: We report on the generation of one-dimensional low spatial frequency LIPSS on transparent material. The influence of the applied laser fluence and angle of incidence on the periodicity, orientation and quality of the one-dimensional low spatial frequency LIPSS is investigated, facilitating the generation of highly uniform LIPSS alongside a line. Most strikingly, however, we observe a previously unreported effect of a pronounced rotation of the one-dimensional low spatial frequency LIPSS for varying angle of incidence upon inclined laser irradiation.

  4. DepositScan, a Scanning Program to Measure Spray Deposition Distributions

    Science.gov (United States)

    DepositScan, a scanning program was developed to quickly measure spray deposit distributions on water sensitive papers or Kromekote cards which are widely used for determinations of pesticide spray deposition quality on target areas. The program is installed in a portable computer and works with a ...

  5. Large Scale Scanning Probe Microscope "Making Shear Force Scanning visible."

    NARCIS (Netherlands)

    Bosma, E.; Offerhaus, Herman L.; van der Veen, Jan T.; van der Veen, J.T.; Segerink, Franciscus B.; Wessel, I.M.

    2010-01-01

    We describe a demonstration of a scanning probe microscope with shear-force tuning fork feedback. The tuning fork is several centimeters long, and the rigid fiber is replaced by a toothpick. By scaling this demonstration to visible dimensions the accessibility of shear-force scanning and tuning fork

  6. Children's early reading vocabulary: description and word frequency lists.

    Science.gov (United States)

    Stuart, Morag; Dixon, Maureen; Masterson, Jackie; Gray, Bob

    2003-12-01

    When constructing stimuli for experimental investigations of cognitive processes in early reading development, researchers have to rely on adult or American children's word frequency counts, as no such counts exist for English children. The present paper introduces a database of children's early reading vocabulary, for use by researchers and teachers. Texts from 685 books from reading schemes and story books read by 5-7 year-old children were used in the construction of the database. All words from the 685 books were typed or scanned into an Oracle database. The resulting up-to-date word frequency list of early print exposure in the UK is available in two forms from a website address given in this paper. This allows access to one list of the words ordered alphabetically and one list of the words ordered by frequency. We also briefly address some fundamental issues underlying early reading vocabulary (e.g., that it is heavily skewed towards low frequencies). Other characteristics of the vocabulary are then discussed. We hope the word frequency lists will be of use to researchers seeking to control word frequency, and to teachers interested in the vocabulary to which young children are exposed in their reading material.

  7. An enhanced CCRTM (E-CCRTM) damage imaging technique using a 2D areal scan for composite plates

    Science.gov (United States)

    He, Jiaze; Yuan, Fuh-Gwo

    2016-04-01

    A two-dimensional (2-D) non-contact areal scan system was developed to image and quantify impact damage in a composite plate using an enhanced zero-lag cross-correlation reverse-time migration (E-CCRTM) technique. The system comprises a single piezoelectric actuator mounted on the composite plate and a laser Doppler vibrometer (LDV) for scanning a region to capture the scattered wavefield in the vicinity of the PZT. The proposed damage imaging technique takes into account the amplitude, phase, geometric spreading, and all of the frequency content of the Lamb waves propagating in the plate; thus, the reflectivity coefficients of the delamination can be calculated and potentially related to damage severity. Comparisons are made in terms of damage imaging quality between 2-D areal scans and linear scans as well as between the proposed and existing imaging conditions. The experimental results show that the 2-D E-CCRTM performs robustly when imaging and quantifying impact damage in large-scale composites using a single PZT actuator with a nearby areal scan using LDV.

  8. Fast IMRT with narrow high energy scanned photon beams

    Energy Technology Data Exchange (ETDEWEB)

    Andreassen, Bjoern; Straaring t, Sara Janek; Holmberg, Rickard; Naefstadius, Peder; Brahme, Anders [Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm (Sweden); Department of Hospital Physics, Karolinska University Hospital, SE-171 76 Stockholm (Sweden); Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, P.O. Box 260, SE-171 76 Stockholm, Sweden and Department of Hospital Physics, Karolinska University Hospital, SE-171 76 Stockholm (Sweden)

    2011-08-15

    beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

  9. Visualization of the microcirculatory network in skin by high frequency optoacoustic mesoscopy

    Science.gov (United States)

    Schwarz, Mathias; Aguirre, Juan; Buehler, Andreas; Omar, Murad; Ntziachristos, Vasilis

    2015-07-01

    Optoacoustic (photoacoustic) imaging has a high potential for imaging melanin-rich structures in skin and the microvasculature of the dermis due to the natural chromophores (de)oxyhemoglobin, and melanin. The vascular network in human dermis comprises a large network of arterioles, capillaries, and venules, ranging from 5 μm to more than 100 μm in diameter. The frequency spectrum of the microcirculatory network in human skin is intrinsically broadband, due to the large variety in size of absorbers. In our group we have developed raster-scan optoacoustic mesoscopy (RSOM) that applies a 100 MHz transducer with ultra-wide bandwidth in raster-scan mode achieving lateral resolution of 18 μm. In this study, we applied high frequency RSOM to imaging human skin in a healthy volunteer. We analyzed the frequency spectrum of anatomical structures with respect to depth and show that frequencies >60 MHz contain valuable information of structures in the epidermis and the microvasculature of the papillary dermis. We illustrate that RSOM is capable of visualizing the fine vascular network at and beneath the epidermal-dermal junction, revealing the vascular fingerprint of glabrous skin, as well as the larger venules deeper inside the dermis. We evaluate the ability of the RSOM system in measuring epidermal thickness in both hairy and glabrous skin. Finally, we showcase the capability of RSOM in visualizing benign nevi that will potentially help in imaging the penetration depth of melanoma.

  10. Fin whale sound reception mechanisms: skull vibration enables low-frequency hearing.

    Directory of Open Access Journals (Sweden)

    Ted W Cranford

    Full Text Available Hearing mechanisms in baleen whales (Mysticeti are essentially unknown but their vocalization frequencies overlap with anthropogenic sound sources. Synthetic audiograms were generated for a fin whale by applying finite element modeling tools to X-ray computed tomography (CT scans. We CT scanned the head of a small fin whale (Balaenoptera physalus in a scanner designed for solid-fuel rocket motors. Our computer (finite element modeling toolkit allowed us to visualize what occurs when sounds interact with the anatomic geometry of the whale's head. Simulations reveal two mechanisms that excite both bony ear complexes, (1 the skull-vibration enabled bone conduction mechanism and (2 a pressure mechanism transmitted through soft tissues. Bone conduction is the predominant mechanism. The mass density of the bony ear complexes and their firmly embedded attachments to the skull are universal across the Mysticeti, suggesting that sound reception mechanisms are similar in all baleen whales. Interactions between incident sound waves and the skull cause deformations that induce motion in each bony ear complex, resulting in best hearing sensitivity for low-frequency sounds. This predominant low-frequency sensitivity has significant implications for assessing mysticete exposure levels to anthropogenic sounds. The din of man-made ocean noise has increased steadily over the past half century. Our results provide valuable data for U.S. regulatory agencies and concerned large-scale industrial users of the ocean environment. This study transforms our understanding of baleen whale hearing and provides a means to predict auditory sensitivity across a broad spectrum of sound frequencies.

  11. Generation of constant-amplitude radio-frequency sweeps at a tunnel junction for spin resonance STM

    International Nuclear Information System (INIS)

    Paul, William; Lutz, Christopher P.; Heinrich, Andreas J.; Baumann, Susanne

    2016-01-01

    We describe the measurement and successful compensation of the radio-frequency transfer function of a scanning tunneling microscope over a wide frequency range (15.5–35.5 GHz) and with high dynamic range (>50 dB). The precise compensation of cabling resonances and attenuations is critical for the production of constant-voltage frequency sweeps for electric-field driven electron spin resonance (ESR) experiments. We also demonstrate that a well-calibrated tunnel junction voltage is necessary to avoid spurious ESR peaks that can arise due to a non-flat transfer function.

  12. Effect of High Frequency Pulsing on the Interfacial Structure of Anodised Aluminium-TiO2

    DEFF Research Database (Denmark)

    Gudla, Visweswara Chakravarthy; Jensen, Flemming; Bordo, Kirill

    2015-01-01

    High frequency anodizing of friction stir processed Al-TiO2 surface composites was investigated. The effect of anodizing parameters on the structure and morphology of the anodic layer including the incorporation of the TiO2 particles into the anodic layer is studied. Anodizing process was carried...... out using a high frequency pulse and pulse reverse pulse technique at a fixed frequency in a sulfuric acid bath. The structure of the composites and the anodized layer was studied using scanning and transmission electron microscopy. The pulse reverse pulse anodizing technique, using a negative...

  13. Generation of constant-amplitude radio-frequency sweeps at a tunnel junction for spin resonance STM

    Energy Technology Data Exchange (ETDEWEB)

    Paul, William; Lutz, Christopher P.; Heinrich, Andreas J. [IBM Research Division, Almaden Research Center, 650 Harry Road, San Jose, California 95120 (United States); Baumann, Susanne [IBM Research Division, Almaden Research Center, 650 Harry Road, San Jose, California 95120 (United States); Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel (Switzerland)

    2016-07-15

    We describe the measurement and successful compensation of the radio-frequency transfer function of a scanning tunneling microscope over a wide frequency range (15.5–35.5 GHz) and with high dynamic range (>50 dB). The precise compensation of cabling resonances and attenuations is critical for the production of constant-voltage frequency sweeps for electric-field driven electron spin resonance (ESR) experiments. We also demonstrate that a well-calibrated tunnel junction voltage is necessary to avoid spurious ESR peaks that can arise due to a non-flat transfer function.

  14. Scanning of bone metastases

    International Nuclear Information System (INIS)

    Robillard, J.

    1977-01-01

    The Centers against cancer of Caen, Angers, Montpellier, Strasbourg and 'the Curie Foundation' have confronted their experience in detection of bone metastases by total body scanning. From the investigation by this procedure, of 1,467 patients with cancer, it results: the confrontation between radio and scanning shows a rate of false positive and false negative identical to the literature ones; the countage scanning allows to reduce the number of false positive; scanning allows to direct bone biopsy and to improve efficiency of histological examination [fr

  15. Transverse section scanning mechanism

    International Nuclear Information System (INIS)

    Doherty, E.J.

    1978-01-01

    Apparatus is described for scanning a transverse, radionuclide scan-field using an array of focussed collimators. The collimators are movable tangentially on rails, driven by a single motor via a coupled screw. The collimators are also movable in a radial direction on rails driven by a step motor via coupled screws and bevel gears. Adjacent bevel gears rotate in opposite directions so adjacent collimators move in radially opposite directions. In use, the focal point of each collimator scans at least half of the scan-field, e.g. a human head located in the central aperture, and the electrical outputs of detectors associated with each collimator are used to determine the distribution of radioactive emission intensity at a number of points in the scan-field. (author)

  16. RubiShort: Reducing scan time in 82Rb heart scans to minimize movements artifacts

    DEFF Research Database (Denmark)

    Madsen, Jeppe; Vraa, Kaspar J.; Harms, Hans

    .013x, R2=0.98; %Reversible: y=1.008x, R2=0.95; TPD: y=1.000x, R2=0.99). Conclusion:, Scan time of myocardial perfusion scans using 82Rb can be reduced from 7 min. to 5 min. without loss of quantitative accuracy. Since patient motion is frequent in the last minutes of the scans, scan time reduction...

  17. Frequencies of micronucleated reticulocytes, a dosimeter of DNA double-strand breaks, in infants receiving computed tomography or cardiac catheterization.

    Science.gov (United States)

    Khattab, Mona; Walker, Dale M; Albertini, Richard J; Nicklas, Janice A; Lundblad, Lennart K A; Vacek, Pamela M; Walker, Vernon E

    2017-08-01

    The use of computed tomography (CT scans) has increased dramatically in recent decades, raising questions about the long-term safety of CT-emitted x-rays especially in infants who are more sensitive to radiation-induced effects. Cancer risk estimates for CT scans typically are extrapolated from models; therefore, new approaches measuring actual DNA damage are needed for improved estimations. Hence, changes in a dosimeter of DNA double-strand breaks, micronucleated reticulocytes (MN-RETs) measured by flow cytometry, were investigated in mice and infants exposed to CT scans. In male C57BL/6N mice (6-8 weeks-of-age), there was a dose-related increase in MN-RETs in blood samples collected 48h after CT scans delivering targeted exposures of 1-130 cGy x-rays (n=5-10/group, r=0.994, p=0.01), with significant increases occurring at exposure levels as low as 0.83 cGy x-rays compared to control mice (p=0.002). In paired blood specimens from infants with no history of a prior CT scan, there was no difference in MN-RET frequencies found 2h before (mean, 0.10±0.07%) versus 48h after (mean, 0.11±0.05%) a scheduled CT scan/cardiac catheterization. However, in infants having prior CT scan(s), MN-RET frequencies measured at 48h after a scheduled CT scan (mean=0.22±0.12%) were significantly higher than paired baseline values (mean, 0.17±0.07%; p=0.032). Increases in baseline (r=0.722, p<0.001) and 48-h post exposure (r=0.682, p<0.001) levels of MN-RETs in infants with a history of prior CT scans were significantly correlated with the number of previous CT scans. These preliminary findings suggest that prior CT scans increase the cellular responses to subsequent CT exposures. Thus, further investigation is needed to characterize the potential cancer risk from single versus repeated CT scans or cardiac catheterizations in infants. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  19. Low-frequency nondestructive analysis of cracks in multilayer structures using a scanning magnetic microscope

    Energy Technology Data Exchange (ETDEWEB)

    Adamo, M; Nappi, C; Sarnelli, E, E-mail: m.adamo@cib.na.cnr.i [Istituto di Cibernetica ' E Caianiello' , Via Campi Flegrei 34, I-80078 Pozzuoli (Italy)

    2010-09-15

    The use of a scanning magnetic microscope (SMM) with a high temperature superconducting quantum interference device (SQUID) for quantitative measurements in eddy current nondestructive analysis (NDA) is presented. The SQUID has been used to detect the weak magnetic field variations around a small defect, close to a structural part generating an intensive magnetic field. The experimental data for a deep crack close to a rivet in a multilayer conducting plate have been taken in a RF-shielded environment and discussed in the light of the theoretical predictions. The results show that eddy current NDA can distinguish subsurface crack signals from wider structural signals, with defects located 10 mm below the surface. Moreover, in order to visualize the structure of the probing current when a circular induction coil is used, the simulation of eddy currents in a thick unflawed conducting plate has been carried out.

  20. Low-frequency nondestructive analysis of cracks in multilayer structures using a scanning magnetic microscope

    International Nuclear Information System (INIS)

    Adamo, M; Nappi, C; Sarnelli, E

    2010-01-01

    The use of a scanning magnetic microscope (SMM) with a high temperature superconducting quantum interference device (SQUID) for quantitative measurements in eddy current nondestructive analysis (NDA) is presented. The SQUID has been used to detect the weak magnetic field variations around a small defect, close to a structural part generating an intensive magnetic field. The experimental data for a deep crack close to a rivet in a multilayer conducting plate have been taken in a RF-shielded environment and discussed in the light of the theoretical predictions. The results show that eddy current NDA can distinguish subsurface crack signals from wider structural signals, with defects located 10 mm below the surface. Moreover, in order to visualize the structure of the probing current when a circular induction coil is used, the simulation of eddy currents in a thick unflawed conducting plate has been carried out.

  1. Nonlinear Near-Field Microwave Microscopy for RF Defect Localization in Nb-Based Superconducting Radio Frequency Cavities

    Science.gov (United States)

    Tai, Tamin

    2011-03-01

    Niobium Superconducting Radio Frequency (SRF) cavities are very sensitive to localized defects that give rise to quenches at high accelerating gradients. In order to identify these defects via scanning microscopy, and to further understand the origins of the quench under high radio frequency excitation (1-3 GHz), a scanning probe with localized and up to ~ 200 mT RF magnetic field is required for low temperature microscopy to achieve sub-micron resolution. For this purpose, we developed a micro loop probe on silicon substrate with outer diameter 20 μ m and inner diameter 17 μ m and successfully fabricated it by lithography. The probe has been used to identify a signal arising from the nonlinear Meissner effect in a Nb thin film. In addition, a magnetic write head is another promising candidate to achieve this goal of understanding localized defect behavior under high RF magnetic field at low temperatures. We will discuss and compare both types of probe for nonlinear scanning microscopy and RF defect localization in superconductors. We acknowledge the support of DOE/HEP.

  2. UAV-borne lidar with MEMS mirror-based scanning capability

    Science.gov (United States)

    Kasturi, Abhishek; Milanovic, Veljko; Atwood, Bryan H.; Yang, James

    2016-05-01

    Firstly, we demonstrated a wirelessly controlled MEMS scan module with imaging and laser tracking capability which can be mounted and flown on a small UAV quadcopter. The MEMS scan module was reduced down to a small volume of smartphone via Bluetooth while flying on a drone, and could project vector content, text, and perform laser based tracking. Also, a "point-and-range" LiDAR module was developed for UAV applications based on low SWaP (Size, Weight and Power) gimbal-less MEMS mirror beam-steering technology and off-the-shelf OEM LRF modules. For demonstration purposes of an integrated laser range finder module, we used a simple off-the-shelf OEM laser range finder (LRF) with a 100m range, +/-1.5mm accuracy, and 4Hz ranging capability. The LRFs receiver optics were modified to accept 20° of angle, matching the transmitter's FoR. A relatively large (5.0mm) diameter MEMS mirror with +/-10° optical scanning angle was utilized in the demonstration to maintain the small beam divergence of the module. The complete LiDAR prototype can fit into a small volume of battery. The MEMS mirror based LiDAR system allows for ondemand ranging of points or areas within the FoR without altering the UAV's position. Increasing the LRF ranging frequency and stabilizing the pointing of the laser beam by utilizing the onboard inertial sensors and the camera are additional goals of the next design.

  3. Re-scan confocal microscopy: scanning twice for better resolution.

    Science.gov (United States)

    De Luca, Giulia M R; Breedijk, Ronald M P; Brandt, Rick A J; Zeelenberg, Christiaan H C; de Jong, Babette E; Timmermans, Wendy; Azar, Leila Nahidi; Hoebe, Ron A; Stallinga, Sjoerd; Manders, Erik M M

    2013-01-01

    We present a new super-resolution technique, Re-scan Confocal Microscopy (RCM), based on standard confocal microscopy extended with an optical (re-scanning) unit that projects the image directly on a CCD-camera. This new microscope has improved lateral resolution and strongly improved sensitivity while maintaining the sectioning capability of a standard confocal microscope. This simple technology is typically useful for biological applications where the combination high-resolution and high-sensitivity is required.

  4. Laser Scanning in Forests

    Directory of Open Access Journals (Sweden)

    Håkan Olsson

    2012-09-01

    Full Text Available The introduction of Airborne Laser Scanning (ALS to forests has been revolutionary during the last decade. This development was facilitated by combining earlier ranging lidar discoveries [1–5], with experience obtained from full-waveform ranging radar [6,7] to new airborne laser scanning systems which had components such as a GNSS receiver (Global Navigation Satellite System, IMU (Inertial Measurement Unit and a scanning mechanism. Since the first commercial ALS in 1994, new ALS-based forest inventory approaches have been reported feasible for operational activities [8–12]. ALS is currently operationally applied for stand level forest inventories, for example, in Nordic countries. In Finland alone, the adoption of ALS for forest data collection has led to an annual savings of around 20 M€/year, and the work is mainly done by companies instead of governmental organizations. In spite of the long implementation times and there being a limited tradition of making changes in the forest sector, laser scanning was commercially and operationally applied after about only one decade of research. When analyzing high-ranked journal papers from ISI Web of Science, the topic of laser scanning of forests has been the driving force for the whole laser scanning research society over the last decade. Thus, the topic “laser scanning in forests” has provided a significant industrial, societal and scientific impact. [...

  5. Digital radiography of scoliosis with a scanning method: radiation dose optimization

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, Haakan; Andersson, Torbjoern [Department of Radiology, Oerebro University Hospital, 701 85 Oerebro (Sweden); Verdonck, Bert [Philips Medical Systems, P.O. Box 10,000, 5680 Best (Netherlands); Beckman, Karl-Wilhelm; Persliden, Jan [Department of Medical Physics, Oerebro University Hospital, 701 85 Oerebro (Sweden)

    2003-03-01

    The aim of this study was optimization of the radiation dose-image quality relationship for a digital scanning method of scoliosis radiography. The examination is performed as a digital multi-image translation scan that is reconstructed to a single image in a workstation. Entrance dose was recorded with thermoluminescent dosimeters placed dorsally on an Alderson phantom. At the same time, kerma area product (KAP) values were recorded. A Monte Carlo calculation of effective dose was also made. Image quality was evaluated with a contrast-detail phantom and Visual Grading. The radiation dose was reduced by lowering the image intensifier entrance dose request, adjusting pulse frequency and scan speed, and by raising tube voltage. The calculated effective dose was reduced from 0.15 to 0.05 mSv with reduction of KAP from 1.07 to 0.25 Gy cm{sup 2} and entrance dose from 0.90 to 0.21 mGy. The image quality was reduced with the Image Quality Figure going from 52 to 62 and a corresponding reduction in image quality as assessed with Visual Grading. The optimization resulted in a dose reduction to 31% of the original effective dose with an acceptable reduction in image quality considering the intended use of the images for angle measurements. (orig.)

  6. Generation of a frequency comb and applications thereof

    Science.gov (United States)

    Hagmann, Mark J; Yarotski, Dmitry A

    2013-12-03

    Apparatus for generating a microwave frequency comb (MFC) in the DC tunneling current of a scanning tunneling microscope (STM) by fast optical rectification, cause by nonlinearity of the DC current vs. voltage curve for the tunneling junction, of regularly-spaced, short pulses of optical radiation from a focused mode-locked, ultrafast laser, directed onto the tunneling junction, is described. Application of the MFC to high resolution dopant profiling in semiconductors is simulated. Application of the MFC to other measurements is described.

  7. Scanning for PIT-tagged flatfish in a coastal area using a sledge equipped with an RFID antenna

    DEFF Research Database (Denmark)

    Sparrevohn, Claus Reedtz; Aarestrup, Kim; Stenberg, Claus

    2014-01-01

    A radio frequency identification (RFID) antenna system, build into a sledge that can be towed behind a vessel like a trawl and thereby has the potential to detect the position of a passive inductor technology (PIT)-tagged fish in a wide variety of habitats, is presented. By scanning for hatchery...

  8. Differential diagnosis of metastases in bone scans: chemotherapy induced bone necrosis

    International Nuclear Information System (INIS)

    Reuland, P.

    1999-01-01

    Aim: Influenced by the incorrect diagnosis of a bone metastasis caused by bone necrosis we evaluated reasons and frequency of bone necrosis in patients referred for bone scanning in follow-up of tumors. Methods: Bone scans performed within two years on patients with primary bone tumors or tumors metastatic to bone were reviewed in respect to the final diagnosis bone necrosis. Results: We found the cases of three young patients who presented the appearance of hot spots on bone scintigrams which were finally diagnosed as bone necrosis. In two cases the diagnosis was based on histological findings, in one case the diagnosis was made evident by follow-up. All the three patients had been treated by chemotherapy and presented no other reason for the development of bone necrosis. Enhanced tracer uptake in all sites decreased within eight weeks up to two years without therapy. Conclusion: Single and multiple hot spots after chemotherapy may be originated by bone necrosis but mimikry metastases. (orig.) [de

  9. Performance of a Rapid-Scan Vacuum Michelson Interferometer at the NSLS

    International Nuclear Information System (INIS)

    Brierly, P.; Dumas, P.; Smith, M.; Williams, G.P.

    2001-01-01

    A commercial Nicolet Magna series rapid-scan Michelson Fourier Transform Infrared (FTIR) was installed in a vacuum housing and integrated into the U4IR beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. The frequency reference laser was mounted outside vacuum, but the moving mirror mechanism and the dynamic alignment system for the fixed mirror were in vacuum. The performance of the instrument was measured in the usual way by measuring the repeatability of data collected under specific conditions of aperture, resolution and mirror scanning velocity. We briefly discuss the beamline design, to put the interferometer in context, then present signal to noise data which we discuss in terms of both instrument performance and also storage ring stability. Under optimal conditions, the instrument has a reproducibility of 0.01% in 1 minute of measuring time at a resolution of 2 cmss, -1 , over a range from 100-3000 cm -1

  10. Optimising 4-D surface change detection: an approach for capturing rockfall magnitude–frequency

    Directory of Open Access Journals (Sweden)

    J. G. Williams

    2018-02-01

    Full Text Available We present a monitoring technique tailored to analysing change from near-continuously collected, high-resolution 3-D data. Our aim is to fully characterise geomorphological change typified by an event magnitude–frequency relationship that adheres to an inverse power law or similar. While recent advances in monitoring have enabled changes in volume across more than 7 orders of magnitude to be captured, event frequency is commonly assumed to be interchangeable with the time-averaged event numbers between successive surveys. Where events coincide, or coalesce, or where the mechanisms driving change are not spatially independent, apparent event frequency must be partially determined by survey interval.The data reported have been obtained from a permanently installed terrestrial laser scanner, which permits an increased frequency of surveys. Surveying from a single position raises challenges, given the single viewpoint onto a complex surface and the need for computational efficiency associated with handling a large time series of 3-D data. A workflow is presented that optimises the detection of change by filtering and aligning scans to improve repeatability. An adaptation of the M3C2 algorithm is used to detect 3-D change to overcome data inconsistencies between scans. Individual rockfall geometries are then extracted and the associated volumetric errors modelled. The utility of this approach is demonstrated using a dataset of  ∼  9  ×  103 surveys acquired at  ∼  1 h intervals over 10 months. The magnitude–frequency distribution of rockfall volumes generated is shown to be sensitive to monitoring frequency. Using a 1 h interval between surveys, rather than 30 days, the volume contribution from small (< 0.1 m3 rockfalls increases from 67 to 98 % of the total, and the number of individual rockfalls observed increases by over 3 orders of magnitude. High-frequency monitoring therefore holds considerable

  11. Optimising 4-D surface change detection: an approach for capturing rockfall magnitude-frequency

    Science.gov (United States)

    Williams, Jack G.; Rosser, Nick J.; Hardy, Richard J.; Brain, Matthew J.; Afana, Ashraf A.

    2018-02-01

    We present a monitoring technique tailored to analysing change from near-continuously collected, high-resolution 3-D data. Our aim is to fully characterise geomorphological change typified by an event magnitude-frequency relationship that adheres to an inverse power law or similar. While recent advances in monitoring have enabled changes in volume across more than 7 orders of magnitude to be captured, event frequency is commonly assumed to be interchangeable with the time-averaged event numbers between successive surveys. Where events coincide, or coalesce, or where the mechanisms driving change are not spatially independent, apparent event frequency must be partially determined by survey interval.The data reported have been obtained from a permanently installed terrestrial laser scanner, which permits an increased frequency of surveys. Surveying from a single position raises challenges, given the single viewpoint onto a complex surface and the need for computational efficiency associated with handling a large time series of 3-D data. A workflow is presented that optimises the detection of change by filtering and aligning scans to improve repeatability. An adaptation of the M3C2 algorithm is used to detect 3-D change to overcome data inconsistencies between scans. Individual rockfall geometries are then extracted and the associated volumetric errors modelled. The utility of this approach is demonstrated using a dataset of ˜ 9 × 103 surveys acquired at ˜ 1 h intervals over 10 months. The magnitude-frequency distribution of rockfall volumes generated is shown to be sensitive to monitoring frequency. Using a 1 h interval between surveys, rather than 30 days, the volume contribution from small (< 0.1 m3) rockfalls increases from 67 to 98 % of the total, and the number of individual rockfalls observed increases by over 3 orders of magnitude. High-frequency monitoring therefore holds considerable implications for magnitude-frequency derivatives, such as hazard return

  12. Advances on Frequency Diverse Array Radar and Its Applications

    Directory of Open Access Journals (Sweden)

    Wang Wenqin

    2018-04-01

    Full Text Available Unlike the conventional phased array that provides only angle-dependent transmit beampattern, Frequency Diverse Array (FDA employs a small frequency increment across its array elements to produce automatic beam scanning without requiring phase shifters or mechanical steering. FDA can produce both rangedependent and time-variant transmit beampatterns, which overcomes the disadvantages of conventional phased arrays that produce only angle-dependent beampattern. Thus, FDA has many promising applications. Based on a previous study conducted by the author, “Frequency Diverse Array Radar: Concept, Principle and Application” (Journal of Electronics & Information Technology, 2016, 38(4: 1000–1011, the current study introduces basic FDA radar concepts, principles, and application characteristics and reviews recent advances on FDA radar and its applications. In addition, several new promising applications of FDA technology are discussed, such as radar electronic warfare and radar-communications, as well as open technical challenges such as beampattern variance, effective receiver design, adaptive signal detection and estimation, and the implementation of practical FDA radar demos.

  13. Analytical examination of a spiral beam scanning method for uniform irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Mitsuhiro; Okumura, Susumu; Arakawa, Kazuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A new circular beam scanning method for uniform irradiation of high-energy, intense ion beams over a large area has been developed. A sweeping speed and a trajectory density in a radial direction are kept constant to obtain uniform fluence distribution. A radial position of a beam spot on a target and an angular frequency of the circular motion are expressed by an irrational function of time. The beam is swept continuously, and a beam trajectory becomes spiral. More than 90 % uniformity of the fluence distribution can been achieved over a large area. (author)

  14. Broadband frequency and angular response of a sinusoidal bull’s eye antenna

    International Nuclear Information System (INIS)

    Beaskoetxea, U; Beruete, M; Navarro-Cía, M

    2016-01-01

    A thorough experimental study of the frequency and beaming angle response of a metallic leaky-wave bull’s eye antenna working at 77 GHz with a sinusoidally corrugated profile is presented. The beam scanning property of these antennas as frequency is varied is experimentally demonstrated and corroborated through theoretical and numerical results. From the experimental results the dispersion diagram of the n   =  −1 and n   =  −2 space harmonics is extracted, and the operation at different frequency regimes is identified and discussed. In order to show the contribution of each half of the antenna, numerical examples of the near-field behavior are also displayed. Overall, experimental results are in good qualitative and quantitative agreement with theoretical and numerical calculations. Finally, an analysis of the beamwidth as a function of frequency is performed, showing that it can achieve values below 1.5° in a fractional bandwidth of 4% around the operation frequency, which is an interesting frequency-stable broadside radiation. (paper)

  15. Four-channel temperature and humidity microwave scanning radiometer

    Science.gov (United States)

    Xu, Pei-Yuan

    1994-06-01

    A compact four-channel microwave scanning radiometer for tropospheric remote sensing is being developed. A pair of 53.85 and 56.02 GHz and a pair of 23.87 and 31.65 GHz are adopted as temperature and humidity channels' frequencies respectively. For each pair of frequencies it has an offset reflector antenna and a Dicke-switching receiver. The pair of receivers is assembled in an enclosure, which is mounted on the rotating table of an azimuth mounting and the pair of antennas is connected with the rotating table of an azimuth mounting in the opposite side by a pair of elevation arms. Each antenna is composed of a 90 degree off-set paraboloid and a conical corrugated horn. Each antenna patterrn of four channels has nearly same HPBW, low side lobes, and low VSWR. The dual band humidity receiver is a time sharing type with 0.2K sensitivity at 1-sec integration time. The dual band temperature receiver is a band sharing type with 0.2K sensitivity at 10-sec integration time. The radiometer and observation are controlled by a single chip microcomputer to realize the unattended operation.

  16. Remote defect imaging for plate-like structures based on the scanning laser source technique

    Science.gov (United States)

    Hayashi, Takahiro; Maeda, Atsuya; Nakao, Shogo

    2018-04-01

    In defect imaging with a scanning laser source technique, the use of a fixed receiver realizes stable measurements of flexural waves generated by laser at multiple rastering points. This study discussed the defect imaging by remote measurements using a laser Doppler vibrometer as a receiver. Narrow-band burst waves were generated by modulating laser pulse trains of a fiber laser to enhance signal to noise ratio in frequency domain. Averaging three images obtained at three different frequencies suppressed spurious distributions due to resonance. The experimental system equipped with these newly-devised means enabled us to visualize defects and adhesive objects in plate-like structures such as a plate with complex geometries and a branch pipe.

  17. Scanning WorldScan. Final report on the presentation and evaluation of WorldScan, a model of the WORLD economy for SCenario ANalysis

    International Nuclear Information System (INIS)

    Geurts, B.; Gielen, A.; Nahuis, R.; Tang, P.; Timmer, H.

    1997-01-01

    An overview is given of the efforts made to present and evaluate WorldScan, a long-term model of the world economy, developed at the Dutch Central Planning Bureau (CPB). One of the pivotal activities was the organisation of a peer review of the model during a two-day workshop. The reviewers were selected both from the academic and the policy field. The main recommendations of that review were (a) not to pursue a formal, full-scale linkage between WorldScan and the RIVM-developed climate model IMAGE. Instead, WorldScan should be used for separate economic analyses, which is input in the climate model; (b) to make more precise choices with respect to the underlying theories the time horizon of the analyses; (c) to improve the empirical base of WorldScan; and (d) to enhance the use of WorldScan for policy analyses on behalf of international policy fora. The review proved to be very beneficial for the evolution of WorldScan. Implementation of some of the recommendations has led to increased use of the model by international institutions. Since the review, WorldScan has been used on behalf of the European Union (EU), the Organisation for Economic Cooperation and Development (OECD), the Energy Modelling Forum (EMF), the Centre for Global Trade Analysis (GTAP), the Chinese Academy of Social Sciences (CASS) and Indian Planning Commission (IPC). 110 refs

  18. In-situ identification of marine organisms using high frequency, wideband ultrasound

    DEFF Research Database (Denmark)

    Pham, An Hoai

    methods. Conventional acoustical methods use frequencies in the range of 10 to 500 kHz and give reasonable estimations of size distribution, if the species is known, but can only significantly support the determination of the actual species, if there are only a few known species available. It is expected...... that higher frequencies and broader bandwidths than used until now will give more information useful for fish species identification. The objective of this Ph.D. study has been to develop a method to investigate the possibility of in-situ identification of fish with high-frequency, wideband ultrasound...... and the fish bodies. The frequencies are 2, 3.5, and 6 MHz. The angles are -30°, -15°, 0°, 15°, and 30°. The results show that even though there are variations, a scan of the ultrasound backscatter along a fish of a specific species contains patterns that are characteristic for that species. This is true...

  19. Codification of scan path parameters and development of perimeter scan strategies for 3D bowl-shaped laser forming

    Science.gov (United States)

    Tavakoli, A.; Naeini, H. Moslemi; Roohi, Amir H.; Gollo, M. Hoseinpour; Shahabad, Sh. Imani

    2018-01-01

    In the 3D laser forming process, developing an appropriate laser scan pattern for producing specimens with high quality and uniformity is critical. This study presents certain principles for developing scan paths. Seven scan path parameters are considered, including: (1) combined linear or curved path; (2) type of combined linear path; (3) order of scan sequences; (4) the position of the start point in each scan; (5) continuous or discontinuous scan path; (6) direction of scan path; and (7) angular arrangement of combined linear scan paths. Regarding these path parameters, ten combined linear scan patterns are presented. Numerical simulations show continuous hexagonal, scan pattern, scanning from outer to inner path, is the optimized. In addition, it is observed the position of the start point and the angular arrangement of scan paths is the most effective path parameters. Also, further experimentations show four sequences due to creat symmetric condition enhance the height of the bowl-shaped products and uniformity. Finally, the optimized hexagonal pattern was compared with the similar circular one. In the hexagonal scan path, distortion value and standard deviation rather to edge height of formed specimen is very low, and the edge height despite of decreasing length of scan path increases significantly compared to the circular scan path. As a result, four-sequence hexagonal scan pattern is proposed as the optimized perimeter scan path to produce bowl-shaped product.

  20. Z-scan: A simple technique for determination of third-order optical nonlinearity

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Vijender, E-mail: chahal-gju@rediffmail.com [Department of Applied Science, N.C. College of Engineering, Israna, Panipat-132107, Haryana (India); Aghamkar, Praveen, E-mail: p-aghamkar@yahoo.co.in [Department of Physics, Chaudhary Devi Lal University, Sirsa-125055, Haryana (India)

    2015-08-28

    Z-scan is a simple experimental technique to measure intensity dependent nonlinear susceptibilities of third-order nonlinear optical materials. This technique is used to measure the sign and magnitude of both real and imaginary part of the third order nonlinear susceptibility (χ{sup (3)}) of nonlinear optical materials. In this paper, we investigate third-order nonlinear optical properties of Ag-polymer composite film by using single beam z-scan technique with Q-switched, frequency doubled Nd: YAG laser (λ=532 nm) at 5 ns pulse. The values of nonlinear absorption coefficient (β), nonlinear refractive index (n{sub 2}) and third-order nonlinear optical susceptibility (χ{sup (3)}) of permethylazine were found to be 9.64 × 10{sup −7} cm/W, 8.55 × 10{sup −12} cm{sup 2}/W and 5.48 × 10{sup −10} esu, respectively.

  1. Uniform deposition of size-selected clusters using Lissajous scanning

    International Nuclear Information System (INIS)

    Beniya, Atsushi; Watanabe, Yoshihide; Hirata, Hirohito

    2016-01-01

    Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt n (n = 7, 15, 20) clusters uniformly deposited on the Al 2 O 3 /NiAl(110) surface and demonstrated the importance of uniform deposition.

  2. Uniform deposition of size-selected clusters using Lissajous scanning

    Energy Technology Data Exchange (ETDEWEB)

    Beniya, Atsushi; Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp [Toyota Central R& D Labs., Inc., 41-1 Yokomichi, Nagakute, Aichi 480-1192 (Japan); Hirata, Hirohito [Toyota Motor Corporation, 1200 Mishuku, Susono, Shizuoka 410-1193 (Japan)

    2016-05-15

    Size-selected clusters can be deposited on the surface using size-selected cluster ion beams. However, because of the cross-sectional intensity distribution of the ion beam, it is difficult to define the coverage of the deposited clusters. The aggregation probability of the cluster depends on coverage, whereas cluster size on the surface depends on the position, despite the size-selected clusters are deposited. It is crucial, therefore, to deposit clusters uniformly on the surface. In this study, size-selected clusters were deposited uniformly on surfaces by scanning the cluster ions in the form of Lissajous pattern. Two sets of deflector electrodes set in orthogonal directions were placed in front of the sample surface. Triangular waves were applied to the electrodes with an irrational frequency ratio to ensure that the ion trajectory filled the sample surface. The advantages of this method are simplicity and low cost of setup compared with raster scanning method. The authors further investigated CO adsorption on size-selected Pt{sub n} (n = 7, 15, 20) clusters uniformly deposited on the Al{sub 2}O{sub 3}/NiAl(110) surface and demonstrated the importance of uniform deposition.

  3. Scanning tunneling microscopy III theory of STM and related scanning probe methods

    CERN Document Server

    Güntherodt, Hans-Joachim

    1996-01-01

    Scanning Tunneling Microscopy III provides a unique introduction to the theoretical foundations of scanning tunneling microscopy and related scanning probe methods. The different theoretical concepts developed in the past are outlined, and the implications of the theoretical results for the interpretation of experimental data are discussed in detail. Therefore, this book serves as a most useful guide for experimentalists as well as for theoreticians working in the filed of local probe methods. In this second edition the text has been updated and new methods are discussed.

  4. Upgrading a high-throughput spectrometer for high-frequency (<400 kHz) measurements

    Science.gov (United States)

    Nishizawa, T.; Nornberg, M. D.; Den Hartog, D. J.; Craig, D.

    2016-11-01

    The upgraded spectrometer used for charge exchange recombination spectroscopy on the Madison Symmetric Torus resolves emission fluctuations up to 400 kHz. The transimpedance amplifier's cutoff frequency was increased based upon simulations comparing the change in the measured photon counts for time-dynamic signals. We modeled each signal-processing stage of the diagnostic and scanned the filtering frequency to quantify the uncertainty in the photon counting rate. This modeling showed that uncertainties can be calculated based on assuming each amplification stage is a Poisson process and by calibrating the photon counting rate with a DC light source to address additional variation.

  5. Upgrading a high-throughput spectrometer for high-frequency (<400 kHz) measurements

    International Nuclear Information System (INIS)

    Nishizawa, T.; Nornberg, M. D.; Den Hartog, D. J.; Craig, D.

    2016-01-01

    The upgraded spectrometer used for charge exchange recombination spectroscopy on the Madison Symmetric Torus resolves emission fluctuations up to 400 kHz. The transimpedance amplifier’s cutoff frequency was increased based upon simulations comparing the change in the measured photon counts for time-dynamic signals. We modeled each signal-processing stage of the diagnostic and scanned the filtering frequency to quantify the uncertainty in the photon counting rate. This modeling showed that uncertainties can be calculated based on assuming each amplification stage is a Poisson process and by calibrating the photon counting rate with a DC light source to address additional variation.

  6. Upgrading a high-throughput spectrometer for high-frequency (<400 kHz) measurements

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, T., E-mail: nishizawa@wisc.edu; Nornberg, M. D.; Den Hartog, D. J. [University of Wisconsin–Madison, Madison, Wisconsin 53706 (United States); Craig, D. [Wheaton College, Wheaton, Illinois 60187 (United States)

    2016-11-15

    The upgraded spectrometer used for charge exchange recombination spectroscopy on the Madison Symmetric Torus resolves emission fluctuations up to 400 kHz. The transimpedance amplifier’s cutoff frequency was increased based upon simulations comparing the change in the measured photon counts for time-dynamic signals. We modeled each signal-processing stage of the diagnostic and scanned the filtering frequency to quantify the uncertainty in the photon counting rate. This modeling showed that uncertainties can be calculated based on assuming each amplification stage is a Poisson process and by calibrating the photon counting rate with a DC light source to address additional variation.

  7. Scanning device for a spectrometer

    International Nuclear Information System (INIS)

    Ignat'ev, V.M.

    1982-01-01

    The invention belongs to scanning devices and is intended for spectrum scanning in spectral devices. The purpose of the invention is broadening of spectral scanning range. The device construction ensures the spectrum scanning range determined from revolution fractions to several revolutions of the monochromator drum head, any number of the drum head revolutions determined by integral number with addition of the drum revolution fractions with high degree of accuracy being possible

  8. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  9. Wafer-level vacuum packaged resonant micro-scanning mirrors for compact laser projection displays

    Science.gov (United States)

    Hofmann, Ulrich; Oldsen, Marten; Quenzer, Hans-Joachim; Janes, Joachim; Heller, Martin; Weiss, Manfred; Fakas, Georgios; Ratzmann, Lars; Marchetti, Eleonora; D'Ascoli, Francesco; Melani, Massimiliano; Bacciarelli, Luca; Volpi, Emilio; Battini, Francesco; Mostardini, Luca; Sechi, Francesco; De Marinis, Marco; Wagner, Bernd

    2008-02-01

    Scanning laser projection using resonant actuated MEMS scanning mirrors is expected to overcome the current limitation of small display size of mobile devices like cell phones, digital cameras and PDAs. Recent progress in the development of compact modulated RGB laser sources enables to set up very small laser projection systems that become attractive not only for consumer products but also for automotive applications like head-up and dash-board displays. Within the last years continuous progress was made in increasing MEMS scanner performance. However, only little is reported on how mass-produceability of these devices and stable functionality even under harsh environmental conditions can be guaranteed. Automotive application requires stable MEMS scanner operation over a wide temperature range from -40° to +85°Celsius. Therefore, hermetic packaging of electrostatically actuated MEMS scanning mirrors becomes essential to protect the sensitive device against particle contamination and condensing moisture. This paper reports on design, fabrication and test of a resonant actuated two-dimensional micro scanning mirror that is hermetically sealed on wafer level. With resonant frequencies of 30kHz and 1kHz, an achievable Theta-D-product of 13mm.deg and low dynamic deformation <20nm RMS it targets Lissajous projection with SVGA-resolution. Inevitable reflexes at the vacuum package surface can be seperated from the projection field by permanent inclination of the micromirror.

  10. Piezoelectric Nanotube Array for Broadband High-Frequency Ultrasonic Transducer.

    Science.gov (United States)

    Liew, Weng Heng; Yao, Kui; Chen, Shuting; Tay, Francis Eng Hock

    2018-03-01

    Piezoelectric materials are vital in determining ultrasonic transducer and imaging performance as they offer the function for conversion between mechanical and electrical energy. Ultrasonic transducers with high-frequency operation suffer from performance degradation and fabrication difficulty of the demanded piezoelectric materials. Hence, we propose 1-D polymeric piezoelectric nanostructure with controlled nanoscale features to overcome the technical limitations of high-frequency ultrasonic transducers. For the first time, we demonstrate the integration of a well-aligned piezoelectric nanotube array to produce a high-frequency ultrasonic transducer with outstanding performance. We find that nanoconfinement-induced polarization orientation and unique nanotube structure lead to significantly improved piezoelectric and ultrasonic transducing performance over the conventional piezoelectric thin film. A large bandwidth, 126% (-6 dB), is achieved at high center frequency, 108 MHz. Transmission sensitivity of nanotube array is found to be 46% higher than that of the monolithic thin film transducer attributed to the improved electromechanical coupling effectiveness and impedance match. We further demonstrate high-resolution scanning, ultrasonic imaging, and photoacoustic imaging using the obtained nanotube array transducers, which is valuable for biomedical imaging applications in the future.

  11. Bone scan in pediatrics

    International Nuclear Information System (INIS)

    Gordon, I.; Peters, A.M.

    1987-01-01

    In 1984, a survey carried out in 21 countries in Europe showed that bone scintigraphy comprised 16% of all paediatric radioisotope scans. Although the value of bone scans in paediatrics is potentially great, their quality varies greatly, and poor-quality images are giving this valuable technique a bad reputation. The handling of children requires a sensitive staff and the provision of a few simple inexpensive items of distraction. Attempting simply to scan a child between two adult patients in a busy general department is a recipe for an unhappy, uncooperative child with the probable result of poor images. The intravenous injection of isotope should be given adjacent to the gamma camera room, unless dynamic scans are required, so that the child does not associate the camera with the injection. This injection is best carried out by someone competent in paediatric venipunture; the entire procedure should be explained to the child and parent, who should remain with child throughout. It is naive to think that silence makes for a cooperative child. The sensitivity of bone-seeking radioisotope tracers and the marked improvement in gamma camera resolution has allowed the bone scanning to become an integrated technique in the assessment of children suspected of suffering from pathological bone conditions. The tracer most commonly used for routine bone scanning is 99m Tc diphosphonate (MDP); other isotopes used include 99m Tc colloid for bone marrow scans and 67 Ga citrate and 111 In white blood cells ( 111 In WBC) for investigation of inflammatory/infective lesions

  12. The utility of repeat sestamibi scans in patients with primary hyperparathyroidism after an initial negative scan.

    Science.gov (United States)

    Krishnamurthy, Vikram D; Sound, Sara; Okoh, Alexis K; Yazici, Pinar; Yigitbas, Hakan; Neumann, Donald; Doshi, Krupa; Berber, Eren

    2017-06-01

    We analyzed the utility of repeated sestambi scans in patients with primary hyperparathyroidism and its effects on operative referral. We carried out a retrospective review of patients with primary hyperparathyroidism who underwent repeated sestambi scans exclusively within our health system between 1996-2015. Patient demographic, presentation, laboratory, imaging, operative, and pathologic data were reviewed. Univariate analysis with JMP Pro v12 was used to identify factors associated with conversion from an initial negative to a subsequent positive scan. After exclusion criteria (including reoperations), we identified 49 patients in whom 59% (n = 29) of subsequent scans remained negative and 41% (n = 20) converted to positive. Factors associated with an initial negative to a subsequent positive scan included classic presentation and second scans with iodine subtraction (P = .04). Nonsurgeons were less likely to order an iodine-subtraction scan (P < .05). Fewer patients with negative imaging were referred to surgery (33% vs 100%, P = .005), and median time to operation after the first negative scan was 25 months (range 1.4-119). Surgeon-performed ultrasonography had greater sensitivity and positive predictive value than repeated sestamibi scans. Negative sestambi scans decreased and delayed operative referral. Consequently, we identified several process improvement initiatives, including education regarding superior institutional imaging. Combining all findings, we created an algorithm for evaluating patients with primary hyperparathyroidism after initially negative sestamibi scans, which incorporates surgeon-performed ultrasonography. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Bone scan and red blood cell scan in a patient with epidermal naevus syndrome

    International Nuclear Information System (INIS)

    Becker, W.; Wolf, F.; Stosiek, N.; Peters, K.P.

    1990-01-01

    A bone scan and red blood cell scan in the rare epidermal naevus syndrome, associated with multiple haemangiomes of the bone and hypophosphataemic osteomalacia in a 20-year-old man are reported. The typical pattern of osteomalacia on the bone scan was associated with lesions of increased bone metabolism in the peripheral bones. The haemangiomas did not pool labelled red blood cells. Thus, the bone scan seems to be suited for diagnosing the complete extent of haemangiomas in bone, but they could not be specifically proven by red blood cell pooling. (orig.)

  14. Internal scanning method as unique imaging method of optical vortex scanning microscope

    Science.gov (United States)

    Popiołek-Masajada, Agnieszka; Masajada, Jan; Szatkowski, Mateusz

    2018-06-01

    The internal scanning method is specific for the optical vortex microscope. It allows to move the vortex point inside the focused vortex beam with nanometer resolution while the whole beam stays in place. Thus the sample illuminated by the focused vortex beam can be scanned just by the vortex point. We show that this method enables high resolution imaging. The paper presents the preliminary experimental results obtained with the first basic image recovery procedure. A prospect of developing more powerful tools for topography recovery with the optical vortex scanning microscope is discussed shortly.

  15. Diagnosis of anemia on CT scans of the thorax

    International Nuclear Information System (INIS)

    Corcoran, H.L.; Cook, D.E.; Proto, A.V.

    1986-01-01

    Visualization of the interventricular septum on nonenhanced CT scans of the thorax of patients with anemia has been illustrated in the literature and explained in terms of a density differential between the cardiac musculature and the blood of anemic patients (blood with a low hemoglobin level). There are no data on the frequency of visualization of the walls of the cardiac chambers, the aorta and its branches, the superior and inferior venae cavae, the brachiocephalic veins, the azygos arch, and so forth. Experience with 50 patients is reported in terms of the foregoing. Findings are correlated with the severity of the anemia, thereby indicating how commonly one may encounter such an appearance

  16. An Intelligent Sensor for the Ultra-High-Frequency Partial Discharge Online Monitoring of Power Transformers

    Directory of Open Access Journals (Sweden)

    Jian Li

    2016-05-01

    Full Text Available Ultra-high-frequency (UHF partial discharge (PD online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequency and wide-frequency band of the UHF PD signal. This paper presents a novel, intelligent sensor for UHF PD online monitoring based on a new method, namely a level scanning method. The intelligent sensor can directly acquire the statistical characteristic quantities and is characterized by low cost, few data to output and transmit, Ethernet functionality, and small size for easy installation. The prototype of an intelligent sensor was made. Actual UHF PD experiments with three typical artificial defect models of power transformers were carried out in a laboratory, and the waveform recording method and intelligent sensor proposed were simultaneously used for UHF PD measurement for comparison. The results show that the proposed intelligent sensor is qualified for the UHF PD online monitoring of power transformers. Additionally, three methods to improve the performance of intelligent sensors were proposed according to the principle of the level scanning method.

  17. Accuracy assessment of high frequency 3D ultrasound for digital impression-taking of prepared teeth

    Science.gov (United States)

    Heger, Stefan; Vollborn, Thorsten; Tinschert, Joachim; Wolfart, Stefan; Radermacher, Klaus

    2013-03-01

    Silicone based impression-taking of prepared teeth followed by plaster casting is well-established but potentially less reliable, error-prone and inefficient, particularly in combination with emerging techniques like computer aided design and manufacturing (CAD/CAM) of dental prosthesis. Intra-oral optical scanners for digital impression-taking have been introduced but until now some drawbacks still exist. Because optical waves can hardly penetrate liquids or soft-tissues, sub-gingival preparations still need to be uncovered invasively prior to scanning. High frequency ultrasound (HFUS) based micro-scanning has been recently investigated as an alternative to optical intra-oral scanning. Ultrasound is less sensitive against oral fluids and in principal able to penetrate gingiva without invasively exposing of sub-gingival preparations. Nevertheless, spatial resolution as well as digitization accuracy of an ultrasound based micro-scanning system remains a critical parameter because the ultrasound wavelength in water-like media such as gingiva is typically smaller than that of optical waves. In this contribution, the in-vitro accuracy of ultrasound based micro-scanning for tooth geometry reconstruction is being investigated and compared to its extra-oral optical counterpart. In order to increase the spatial resolution of the system, 2nd harmonic frequencies from a mechanically driven focused single element transducer were separated and corresponding 3D surface models were calculated for both fundamentals and 2nd harmonics. Measurements on phantoms, model teeth and human teeth were carried out for evaluation of spatial resolution and surface detection accuracy. Comparison of optical and ultrasound digital impression taking indicate that, in terms of accuracy, ultrasound based tooth digitization can be an alternative for optical impression-taking.

  18. Mouse manipulation through single-switch scanning.

    Science.gov (United States)

    Blackstien-Adler, Susie; Shein, Fraser; Quintal, Janet; Birch, Shae; Weiss, Patrice L Tamar

    2004-01-01

    Given the current extensive reliance on the graphical user interface, independent access to computer software requires that users be able to manipulate a pointing device of some type (e.g., mouse, trackball) or be able to emulate a mouse by some other means (e.g., scanning). The purpose of the present study was to identify one or more optimal single-switch scanning mouse emulation strategies. Four alternative scanning strategies (continuous Cartesian, discrete Cartesian, rotational, and hybrid quadrant/continuous Cartesian) were selected for testing based on current market availability as well as on theoretical considerations of their potential speed and accuracy. Each strategy was evaluated using a repeated measures study design by means of a test program that permitted mouse emulation via any one of four scanning strategies in a motivating environment; response speed and accuracy could be automatically recorded and considered in view of the motor, cognitive, and perceptual demands of each scanning strategy. Ten individuals whose disabilities required them to operate a computer via single-switch scanning participated in the study. Results indicated that Cartesian scanning was the preferred and most effective scanning strategy. There were no significant differences between results from the Continuous Cartesian and Discrete Cartesian scanning strategies. Rotational scanning was quite slow with respect to the other strategies, although it was equally accurate. Hybrid Quadrant scanning improved access time but at the cost of fewer correct selections. These results demonstrated the importance of testing and comparing alternate single-switch scanning strategies.

  19. Comparison of dimensional accuracy of digital dental models produced from scanned impressions and scanned stone casts

    Science.gov (United States)

    Subeihi, Haitham

    Introduction: Digital models of dental arches play a more and more important role in dentistry. A digital dental model can be generated by directly scanning intraoral structures, by scanning a conventional impression of oral structures or by scanning a stone cast poured from the conventional impression. An accurate digital scan model is a fundamental part for the fabrication of dental restorations. Aims: 1. To compare the dimensional accuracy of digital dental models produced by scanning of impressions versus scanning of stone casts. 2. To compare the dimensional accuracy of digital dental models produced by scanning of impressions made of three different materials (polyvinyl siloxane, polyether or vinyl polyether silicone). Methods and Materials: This laboratory study included taking addition silicone, polyether and vinyl polyether silicone impressions from an epoxy reference model that was created from an original typodont. Teeth number 28 and 30 on the typodont with a missing tooth number 29 were prepared for a metal-ceramic three-unit fixed dental prosthesis with tooth #29 being a pontic. After tooth preparation, an epoxy resin reference model was fabricated by duplicating the typodont quadrant that included the tooth preparations. From this reference model 12 polyvinyl siloxane impressions, 12 polyether impressions and 12 vinyl polyether silicone impressions were made. All 36 impressions were scanned before pouring them with dental stone. The 36 dental stone casts were, in turn, scanned to produce digital models. A reference digital model was made by scanning the reference model. Six groups of digital models were produced. Three groups were made by scanning of the impressions obtained with the three different materials, the other three groups involved the scanning of the dental casts that resulted from pouring the impressions made with the three different materials. Groups of digital models were compared using Root Mean Squares (RMS) in terms of their

  20. Scanning magnetic tunnel junction microscope for high-resolution imaging of remanent magnetization fields

    Science.gov (United States)

    Lima, E. A.; Bruno, A. C.; Carvalho, H. R.; Weiss, B. P.

    2014-10-01

    Scanning magnetic microscopy is a new methodology for mapping magnetic fields with high spatial resolution and field sensitivity. An important goal has been to develop high-performance instruments that do not require cryogenic technology due to its high cost, complexity, and limitation on sensor-to-sample distance. Here we report the development of a low-cost scanning magnetic microscope based on commercial room-temperature magnetic tunnel junction (MTJ) sensors that typically achieves spatial resolution better than 7 µm. By comparing different bias and detection schemes, optimal performance was obtained when biasing the MTJ sensor with a modulated current at 1.0 kHz in a Wheatstone bridge configuration while using a lock-in amplifier in conjunction with a low-noise custom-made preamplifier. A precision horizontal (x-y) scanning stage comprising two coupled nanopositioners controls the position of the sample and a linear actuator adjusts the sensor-to-sample distance. We obtained magnetic field sensitivities better than 150 nT/Hz1/2 between 0.1 and 10 Hz, which is a critical frequency range for scanning magnetic microscopy. This corresponds to a magnetic moment sensitivity of 10-14 A m2, a factor of 100 better than achievable with typical commercial superconducting moment magnetometers. It also represents an improvement in sensitivity by a factor between 10 and 30 compared to similar scanning MTJ microscopes based on conventional bias-detection schemes. To demonstrate the capabilities of the instrument, two polished thin sections of representative geological samples were scanned along with a synthetic sample containing magnetic microparticles. The instrument is usable for a diversity of applications that require mapping of samples at room temperature to preserve magnetic properties or viability, including paleomagnetism and rock magnetism, nondestructive evaluation of materials, and biological assays.

  1. Scanning magnetic tunnel junction microscope for high-resolution imaging of remanent magnetization fields

    International Nuclear Information System (INIS)

    Lima, E A; Weiss, B P; Bruno, A C; Carvalho, H R

    2014-01-01

    Scanning magnetic microscopy is a new methodology for mapping magnetic fields with high spatial resolution and field sensitivity. An important goal has been to develop high-performance instruments that do not require cryogenic technology due to its high cost, complexity, and limitation on sensor-to-sample distance. Here we report the development of a low-cost scanning magnetic microscope based on commercial room-temperature magnetic tunnel junction (MTJ) sensors that typically achieves spatial resolution better than 7 µm. By comparing different bias and detection schemes, optimal performance was obtained when biasing the MTJ sensor with a modulated current at 1.0 kHz in a Wheatstone bridge configuration while using a lock-in amplifier in conjunction with a low-noise custom-made preamplifier. A precision horizontal (x–y) scanning stage comprising two coupled nanopositioners controls the position of the sample and a linear actuator adjusts the sensor-to-sample distance. We obtained magnetic field sensitivities better than 150 nT/Hz 1/2 between 0.1 and 10 Hz, which is a critical frequency range for scanning magnetic microscopy. This corresponds to a magnetic moment sensitivity of 10 –14  A m 2 , a factor of 100 better than achievable with typical commercial superconducting moment magnetometers. It also represents an improvement in sensitivity by a factor between 10 and 30 compared to similar scanning MTJ microscopes based on conventional bias-detection schemes. To demonstrate the capabilities of the instrument, two polished thin sections of representative geological samples were scanned along with a synthetic sample containing magnetic microparticles. The instrument is usable for a diversity of applications that require mapping of samples at room temperature to preserve magnetic properties or viability, including paleomagnetism and rock magnetism, nondestructive evaluation of materials, and biological assays. (paper)

  2. Factors influencing bone scan quality

    International Nuclear Information System (INIS)

    Adams, F.G.; Shirley, A.W.

    1983-01-01

    A reliable subjective method of assessing bone scan quality is described. A large number of variables which theoretically could influence scan quality were submitted to regression and factor analysis. Obesity, age, sex and abnormality of scan were found to be significant but weak variables. (orig.)

  3. Drive frequency dependent phase imaging in piezoresponse force microscopy

    International Nuclear Information System (INIS)

    Bo Huifeng; Kan Yi; Lu Xiaomei; Liu Yunfei; Peng Song; Wang Xiaofei; Cai Wei; Xue Ruoshi; Zhu Jinsong

    2010-01-01

    The drive frequency dependent piezoresponse (PR) phase signal in near-stoichiometric lithium niobate crystals is studied by piezoresponse force microscopy. It is clearly shown that the local and nonlocal electrostatic forces have a great contribution to the PR phase signal. The significant PR phase difference of the antiparallel domains are observed at the contact resonances, which is related to the electrostatic dominated electromechanical interactions of the cantilever and tip-sample system. Moreover, the modulation voltage induced frequency shift at higher eigenmodes could be attributed to the change of indention force depending on the modulation amplitude with a piezoelectric origin. The PR phase of the silicon wafer is also measured for comparison. It is certificated that the electrostatic interactions are universal in voltage modulated scanning probe microscopy and could be extended to other phase imaging techniques.

  4. A CdZnTe slot-scanned detector for digital mammography

    International Nuclear Information System (INIS)

    Mainprize, James G.; Ford, Nancy L.; Yin Shi; Gordon, Eli E.; Hamilton, William J.; Tuemer, Tuemay O.; Yaffe, Martin J.

    2002-01-01

    A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-μm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of 50 μm. Two devices were evaluated with differing crystalline quality. Incomplete charge collection was a source of reduction in DQE. This occurs in both devices due to characteristically low mobility-lifetime products for CdZnTe, with the greatest losses demonstrated by the multicrystalline sample. The mobility-lifetime products for the multicrystalline device were found to be 2.4x10 -4 and 4.0x10 -7 cm 2 /V for electrons and holes, respectively. The device constructed with higher quality single crystal CdZnTe demonstrated mobility-lifetime products of 1.0x10 -4 and 4.4x10 -6 cm 2 /V for electrons and holes. The MTF and DQE for the device were measured at several exposures and results were compared to predictions from a linear systems model of signal and noise propagation. The MTF at a spatial frequency of 10 mm -1 exceeded 0.18 and 0.56 along the scan and slot directions, respectively. Scanning motion and CCD design limited the resolution along the scan direction. For an x-ray beam from a tungsten target tube with 40 μm molybdenum filtration operated at 26 kV, the single crystal device demonstrated a DQE(0) of 0.70±0.02 at 7.1x10 -6 C/kg (27 mR) exposure to the detector, despite its relatively poor charge collection efficiency

  5. Vertical Scan-Conversion for Filling Purposes

    OpenAIRE

    Hersch, R. D.

    1988-01-01

    Conventional scan-conversion algorithms were developed independently of filling algorithms. They cause many problems, when used for filling purposes. However, today's raster printers and plotters require extended use of filling, especially for the generation of typographic characters and graphic line art. A new scan-conversion algorithm, called vertical scan-conversion has been specifically designed to meet the requirements of parity scan line fill algorithms. Vertical scan-conversion ensures...

  6. High frequency fatigue test of IN 718 alloy – microstructure and fractography evaluation

    Directory of Open Access Journals (Sweden)

    J. Belan

    2015-01-01

    Full Text Available INCONEL alloy 718 is a high-strength, corrosion-resistant nickel chromium material used at -253 °C to 705 °C for production of heat resistant parts of aero jet engine mostly. The fatigue test provided on this kind materials were done via low frequency loading up to this time. Nowadays, needs of results at higher volume of loading cycles leads to high frequency loading with aim to shorten testing time. Fatigue test of experimental material was carried out at frequency 20 kHz with stress ration R = - 1 (push – pull at room temperature. It was found that this superalloy can still fracture after exceeding 108 cycles. Besides fatigue test were microstructural characterisation and scanning electron microscopy (SEM fractography evaluation done.

  7. Sex differences in Hadza eating frequency by food type.

    Science.gov (United States)

    Berbesque, J Colette; Marlowe, Frank W; Crittenden, Alyssa N

    2011-01-01

    We investigate sex differences in frequencies of adults eating in a foraging population-the Hadza of Tanzania. We use eating frequency data from instantaneous scan observations of the Hadza, to see to how much sharing of foods taken back to camp compensates for the targeting of different foods by each sex while out foraging. Eating in camp differs by sex in terms of overall eating frequency, as well as in terms of diet composition (frequencies of eating each food type). We also control for sex-differences in time spent in camp and still find sex-differences in eating frequencies-women are observed eating significantly more frequently than men. There are also sex-differences in the eating frequencies of particular food types both with and without controlling for presence in camp. Finally, we use data on acquisition of each food type by sex and find that both sexes are more frequently observed eating women's foods in camp than men's foods. At least in the case of the Hadza, we see pronounced sex differences in the in-camp diet. Hadza men are eating a higher quality diet than are women, but women are able to eat far more frequently, and spend less time foraging than men. It is not yet clear whether a regular caloric intake of lower quality foods would be more beneficial for maintaining fecundity than a more variable diet consisting of higher quality foods. Copyright © 2011 Wiley-Liss, Inc.

  8. Atmospheric water distribution in cyclones as seen with Scanning Multichannel Microwave Radiometers (SMMR)

    Science.gov (United States)

    Katsaros, K. B.; Mcmurdie, L. A.

    1983-01-01

    Passive microwave measurements are used to study the distribution of atmospheric water in midlatitude cyclones. The integrated water vapor, integrated liquid water, and rainfall rate are deduced from the brightness temperatures at microwave frequencies measured by the Scanning Multichannel Microwave Radiometer (SMRR) flown on both the Seasat and Nimbus 7 satellites. The practical application of locating fronts by the cyclone moisture pattern over oceans is shown, and the relationship between the quantity of coastal rainfall and atmospheric water content is explored.

  9. Scan posture definition and hip girth measurement: the impact on clothing design and body scanning.

    Science.gov (United States)

    Gill, Simeon; Parker, Christopher J

    2017-08-01

    Ergonomic measurement is central to product design and development; especially for body worn products and clothing. However, there is a large variation in measurement definitions, complicated by new body scanning technology that captures measurements in a posture different to traditional manual methods. Investigations of hip measurement definitions in current clothing measurement practices supports analysis of the effect of scan posture and hip measurement definition on the circumferences of the hip. Here, the hip girth is a key clothing measurement that is not defined in current body scanning measurement standards. Sixty-four participants were scanned in the standard scan posture of a [TC] 2 body scanner, and also in a natural posture similar to that of traditional manual measurement collection. Results indicate that scan posture affects hip girth circumferences, and that some current clothing measurement practices may not define the largest lower body circumference. Recommendations are made concerning how the hip is defined in measurement practice and within body scanning for clothing product development. Practitioner Summary: The hip girth is an important measurement in garment design, yet its measurement protocol is not currently defined. We demonstrate that body posture during body scanning affects hip circumferences, and that current clothing measurement practices may not define the largest lower body circumference. This paper also provides future measurement practice recommendations.

  10. Introducing Discrete Frequency Infrared Technology for High-Throughput Biofluid Screening

    Science.gov (United States)

    Hughes, Caryn; Clemens, Graeme; Bird, Benjamin; Dawson, Timothy; Ashton, Katherine M.; Jenkinson, Michael D.; Brodbelt, Andrew; Weida, Miles; Fotheringham, Edeline; Barre, Matthew; Rowlette, Jeremy; Baker, Matthew J.

    2016-02-01

    Accurate early diagnosis is critical to patient survival, management and quality of life. Biofluids are key to early diagnosis due to their ease of collection and intimate involvement in human function. Large-scale mid-IR imaging of dried fluid deposits offers a high-throughput molecular analysis paradigm for the biomedical laboratory. The exciting advent of tuneable quantum cascade lasers allows for the collection of discrete frequency infrared data enabling clinically relevant timescales. By scanning targeted frequencies spectral quality, reproducibility and diagnostic potential can be maintained while significantly reducing acquisition time and processing requirements, sampling 16 serum spots with 0.6, 5.1 and 15% relative standard deviation (RSD) for 199, 14 and 9 discrete frequencies respectively. We use this reproducible methodology to show proof of concept rapid diagnostics; 40 unique dried liquid biopsies from brain, breast, lung and skin cancer patients were classified in 2.4 cumulative seconds against 10 non-cancer controls with accuracies of up to 90%.

  11. Incidental bone scan findings in oral cavity in patients with cancer

    International Nuclear Information System (INIS)

    Gutierrez G, Patricia; Salvatierra R, Guillermo; Garcia, Arlene; Morales, Rosanna; Cano, Roque; Ortiz L, Jesus; Sotelo R, Silvia; Bustamante, Cesar

    2007-01-01

    The main aim of the present work, done in the Nuclear medicine Center IPEN-INEN, was to identify as incidental findings, increased inflammatory uptake in oral cavity in routine bone scintigraphies for neoplasic diseases control. A descriptive and retrospective study was performed studying bone scans from patients with cancer, that came to the Nuclear Medicine Center in 2003 and revising records of those who had inflammatory uptake in the oral cavity. It is concluded that, in cancer patients these findings are underestimated. Prospective research should be needed in order to determine the frequency of inflammatory oral cavity pathology detected in bone scintigraphies. (author)

  12. Photonic crystal fibre enables short-wavelength two-photon laser scanning fluorescence microscopy with fura-2

    International Nuclear Information System (INIS)

    McConnell, Gail; Riis, Erling

    2004-01-01

    We report on a novel and compact reliable laser source capable of short-wavelength two-photon laser scanning fluorescence microscopy based on soliton self-frequency shift effects in photonic crystal fibre. We demonstrate the function of the system by performing two-photon microscopy of smooth muscle cells and cardiac myocytes from the rat pulmonary vein and Chinese hamster ovary cells loaded with the fluorescent calcium indicator fura-2/AM

  13. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Scan and Uptake Thyroid scan and uptake uses small amounts of radioactive materials called radiotracers, a special ... is a branch of medical imaging that uses small amounts of radioactive material to diagnose and determine ...

  14. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Most thyroid scan and thyroid uptake ... you otherwise, you may resume your normal activities after your nuclear medicine scan. If any special instructions ...

  15. Light emission and finite-frequency shot noise in molecular junctions: from tunneling to contact

    DEFF Research Database (Denmark)

    Lu, Jing Tao; Christensen, Rasmus Bjerregaard; Brandbyge, Mads

    2013-01-01

    Scanning tunneling microscope induced light emission from an atomic or molecular junction has been probed from the tunneling to contact regime in recent experiments. There, the measured light emission yields suggest a strong correlation with the high-frequency current/charge fluctuations. We show...... that this is consistent with the established theory in the tunneling regime, by writing the finite-frequency shot noise as a sum of inelastic transitions between different electronic states. Based on this, we develop a practical scheme to perform calculations on realistic structures using nonequilibrium Green's functions...

  16. The boundary-scan handbook

    CERN Document Server

    Parker, Kenneth P

    2016-01-01

    Aimed at electronics industry professionals, this 4th edition of the Boundary Scan Handbook describes recent changes to the IEEE1149.1 Standard Test Access Port and Boundary-Scan Architecture. This updated edition features new chapters on the possible effects of the changes on the work of the practicing test engineers and the new 1149.8.1 standard. Anyone needing to understand the basics of boundary scan and its practical industrial implementation will need this book. Provides an overview of the recent changes to the 1149.1 standard and the effect of the changes on the work of test engineers;   Explains the new IEEE 1149.8.1 subsidiary standard and applications;   Describes the latest updates on the supplementary IEEE testing standards. In particular, addresses: IEEE Std 1149.1                      Digital Boundary-Scan IEEE Std 1149.4                      Analog Boundary-Scan IEEE Std 1149.6                      Advanced I/O Testing IEEE Std 1149.8.1           �...

  17. Combinatorial Mismatch Scan (CMS for loci associated with dementia in the Amish

    Directory of Open Access Journals (Sweden)

    Vance Jeffery M

    2006-03-01

    Full Text Available Abstract Background Population heterogeneity may be a significant confounding factor hampering detection and verification of late onset Alzheimer's disease (LOAD susceptibility genes. The Amish communities located in Indiana and Ohio are relatively isolated populations that may have increased power to detect disease susceptibility genes. Methods We recently performed a genome scan of dementia in this population that detected several potential loci. However, analyses of these data are complicated by the highly consanguineous nature of these Amish pedigrees. Therefore we applied the Combinatorial Mismatch Scanning (CMS method that compares identity by state (IBS (under the presumption of identity by descent (IBD sharing in distantly related individuals from such populations where standard linkage and association analyses are difficult to implement. CMS compares allele sharing between individuals in affected and unaffected groups from founder populations. Comparisons between cases and controls were done using two Fisher's exact tests, one testing for excess in IBS allele frequency and the other testing for excess in IBS genotype frequency for 407 microsatellite markers. Results In all, 13 dementia cases and 14 normal controls were identified who were not related at least through the grandparental generation. The examination of allele frequencies identified 24 markers (6% nominally (p ≤ 0.05 associated with dementia; the most interesting (empiric p ≤ 0.005 markers were D3S1262, D5S211, and D19S1165. The examination of genotype frequencies identified 21 markers (5% nominally (p ≤ 0.05 associated with dementia; the most significant markers were both located on chromosome 5 (D5S1480 and D5S211. Notably, one of these markers (D5S211 demonstrated differences (empiric p ≤ 0.005 under both tests. Conclusion Our results provide the initial groundwork for identifying genes involved in late-onset Alzheimer's disease within the Amish community. Genes

  18. Intercomparison of two dynamic treatment techniques, ring scan and spot scan, for head and neck tumors with the Piotron

    International Nuclear Information System (INIS)

    Takai, M.; Blattmann, H.; Pedroni, E.

    1988-01-01

    An evaluation of the ring scan and the spot scan was made for the pion irradiation of head and neck tumors with the Piotron. For the geometry of the Piotron, with its 60 radially converging beams, two scanning techniques have been developed, ring scan and spot scan. They have different characteristics concerning achievable dose distributions and sensitivity to tissue inhomogenities. The optimized 3-dimensional dose distributions for the treatment with ring scan and spot scan techniques were calculated for two examples of the target volume. The comparison of the dose distributions has shown that the ring scan is better in sparing normal tissues than the spot scan for a simple shape target volume but not for an irregular shape target volume with the present status of the technique. The irradiation time needed for the ring scan is longer, for the present examples three times, than for the spot scan. From the practical view point the spot scan is preferable to the ring scan for the treatment of head and neck tumors with the Piotron

  19. Multiple myeloma: radiology or bone scanning

    International Nuclear Information System (INIS)

    Leonard, R.C.F.; Owen, J.P.; Proctor, S.J.; Hamilton, P.J.

    1981-01-01

    A comparative study of radionuclide bone scanning and skeletal radiology in patients with multiple myeloma revealed four principal findings: (i) There were no cases of negative bone scans with positive skeletal radiographs. (ii) Lytic bone lesions were seriously underestimated by bone scans. (iii) Bone scans tended to pick up lesions in ribs missed on the skeletal surveys. (iv) Patients with bone pain were more likely to have positive bone scans and skeletal radiographs than asymptomatic patients. (author)

  20. Are environmental scanning units effective?

    Science.gov (United States)

    Stubbart, C

    1982-06-01

    Many authorities have urged companies to set up environmental scanning to assist corporate planning. Some advocates have recommended a unit at corporate level. This would give breadth of view and penetration into the future. It would arm decision makers with accurate forecasts. The information would be broad in scope and future directed. It could provide also assumptions for long-range planning. The Fahey and King study produced a model of corporate scanning types. The data showed that environmental information was built into the plan. Though the political environment was important, scanning was inadequate. The best location for scanning was not at corporate level and most firms used irregular methods. The Thomas study concluded that effective environmental scanning was permanent and multi level and that 'best practice' was continuous scanning. In 1978 the sample organizations were revisited. Five of the twelve have not changed their practice. The factors which encouraged a continuous model were the attitudes of academics and business media, demonstrated success of the units, the right kind of personnel. Contrary influences were changes in top management, decentralization moves, resource cuts, defining the environment and its significance, the availability of scanning competent personnel, surprise itself, and the availability of alternatives e.g. external forecasts.

  1. Analysis of calibration-free wavelength-scanned wavelength modulation spectroscopy for practical gas sensing using tunable diode lasers

    Science.gov (United States)

    Sun, K.; Chao, X.; Sur, R.; Goldenstein, C. S.; Jeffries, J. B.; Hanson, R. K.

    2013-12-01

    A novel strategy has been developed for analysis of wavelength-scanned, wavelength modulation spectroscopy (WMS) with tunable diode lasers (TDLs). The method simulates WMS signals to compare with measurements to determine gas properties (e.g., temperature, pressure and concentration of the absorbing species). Injection-current-tuned TDLs have simultaneous wavelength and intensity variation, which severely complicates the Fourier expansion of the simulated WMS signal into harmonics of the modulation frequency (fm). The new method differs from previous WMS analysis strategies in two significant ways: (1) the measured laser intensity is used to simulate the transmitted laser intensity and (2) digital lock-in and low-pass filter software is used to expand both simulated and measured transmitted laser intensities into harmonics of the modulation frequency, WMS-nfm (n = 1, 2, 3,…), avoiding the need for an analytic model of intensity modulation or Fourier expansion of the simulated WMS harmonics. This analysis scheme is valid at any optical depth, modulation index, and at all values of scanned-laser wavelength. The method is demonstrated and validated with WMS of H2O dilute in air (1 atm, 296 K, near 1392 nm). WMS-nfm harmonics for n = 1 to 6 are extracted and the simulation and measurements are found in good agreement for the entire WMS lineshape. The use of 1f-normalization strategies to realize calibration-free wavelength-scanned WMS is also discussed.

  2. Bone scans

    International Nuclear Information System (INIS)

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  3. Method for calibration-free scanned-wavelength modulation spectroscopy for gas sensing

    Science.gov (United States)

    Hanson, Ronald K.; Jeffries, Jay B.; Sun, Kai; Sur, Ritobrata; Chao, Xing

    2018-04-10

    A method of calibration-free scanned-wavelength modulation spectroscopy (WMS) absorption sensing is provided by obtaining absorption lineshape measurements of a gas sample on a sensor using 1f-normalized WMS-2f where an injection current to an injection current-tunable diode laser (TDL) is modulated at a frequency f, where a wavelength modulation and an intensity modulation of the TDL are simultaneously generated, extracting using a numerical lock-in program and a low-pass filter appropriate band-width WMS-nf (n=1, 2, . . . ) signals, where the WMS-nf signals are harmonics of the f, determining a physical property of the gas sample according to ratios of the WMS-nf signals, determining the zero-absorption background using scanned-wavelength WMS, and determining non-absorption losses using at least two of the harmonics, where a need for a non-absorption baseline measurement is removed from measurements in environments where collision broadening has blended transition linewidths, where calibration free WMS measurements without knowledge of the transition linewidth is enabled.

  4. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ...

  5. 99mTc-MDP Three Phase Bone Scan - An Important Imaging Modality in the Diagnosis of Bone Infection in Children

    International Nuclear Information System (INIS)

    Sethi, R.S.; Mittal, B.R.; Bhattacharya, A.; Singh, B.; Jindal, S.K.

    2002-01-01

    In patients suspected to have osteomyelitis, three-phase bone scan is one of the earlier investigations to become positive. Early diagnosis helps in starting the appropriate therapy and thus reducing morbidity. A retrospective analysis of scintigraphic findings of 53 children (37 boys, 16 girls) with mean age of 7.4 years (25 days - 2 years), referred for three-phase bone scan to rule out osteomyelitis was done. The presenting signs and symptoms in all children in order of frequency were swelling of body part, guarding, fever of unknown origin. Limitation of movement of body part was the most frequent sign in infants below 6 months of age. In 32 (60.3%) of these 53 children, x-rays were normal. Eleven (20.7%) of the 53 children had normal three phase bone scan. Nine children (16.9%) had increased blood flow along with increased soft tissue tracer concentration in the involved area suggesting soft tissue inflammation / infection. Five (9.4%) children who presented with multiple abscesses over extremities with the suspicion of immunodeficiency also had positive three-phase bone scan. All these 5 children had pus culture positive for staphylococcus aureus. Four (7.5%) children had thalassemia major and were on regular blood transfusion. Three of these 4 children showed positive three-phase bone scan while in the fourth patient bone phase (3rd phase) was normal suggesting soft tissue inflammation only. One child who was a case of Non-Hodgkin's lymphoma and had recently finished chemotherapy also showed positive three-phase bone scan. One infant who had positive three-phase bone scan with nonspecific abnormality on chest x-ray was diagnosed to have Caffey's disease, while his other twin showed a normal bone scan. In twenty-four children (45.2%) three-phase bone scan was positive involving mostly one extremity. According to the frequency of site of involvement these were knee, elbow and ankle. Most frequent bones involved were femur followed by humerus. Staphylococcus

  6. Comparative study between ultrahigh spatial frequency algorithm and high spatial frequency algorithm in high-resolution CT of the lungs

    International Nuclear Information System (INIS)

    Oh, Yu Whan; Kim, Jung Kyuk; Suh, Won Hyuck

    1994-01-01

    To date, the high spatial frequency algorithm (HSFA) which reduces image smoothing and increases spatial resolution has been used for the evaluation of parenchymal lung diseases in thin-section high-resolution CT. In this study, we compared the ultrahigh spatial frequency algorithm (UHSFA) with the high spatial frequency algorithm in the assessment of thin section images of the lung parenchyma. Three radiologists compared the UHSFA and HSFA on identical CT images in a line-pair resolution phantom, one lung specimen, 2 patients with normal lung and 18 patients with abnormal lung parenchyma. Scanning of a line-pair resolution phantom demonstrated no difference in resolution between two techniques but it showed that outer lines of the line pairs with maximal resolution looked thicker on UHSFA than those on HSFA. Lung parenchymal detail with UHSFA was judged equal or superior to HSFA in 95% of images. Lung parenchymal sharpness was improved with UHSFA in all images. Although UHSFA resulted in an increase in visible noise, observers did not found that image noise interfered with image interpretation. The visual CT attenuation of normal lung parenchyma is minimally increased in images with HSFA. The overall visual preference of the images reconstructed on UHSFA was considered equal to or greater than that of those reconstructed on HSFA in 78% of images. The ultrahigh spatial frequency algorithm improved the overall visual quality of the images in pulmonary parenchymal high-resolution CT

  7. A near-field scanning microwave microscope based on a superconducting resonator for low power measurements.

    Science.gov (United States)

    de Graaf, S E; Danilov, A V; Adamyan, A; Kubatkin, S E

    2013-02-01

    We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100 μV, approaching low enough photon population (N ∼ 1000) of the resonator such that coherent quantum manipulation becomes feasible. The resonator is made out of a miniaturized distributed fractal superconducting circuit that is integrated with the probing tip, micromachined to be compact enough such that it can be mounted directly on a quartz tuning-fork, and used for parallel operation as an atomic force microscope (AFM). The resonator is magnetically coupled to a transmission line for readout, and to achieve enhanced sensitivity we employ a Pound-Drever-Hall measurement scheme to lock to the resonance frequency. We achieve a well localized near-field around the tip such that the microwave resolution is comparable to the AFM resolution, and a capacitive sensitivity down to 6.4 × 10(-20) F/Hz, limited by mechanical noise. We believe that the results presented here are a significant step towards probing quantum systems at the nanoscale using near-field scanning microwave microscopy.

  8. Scanning tunnel microscope with large vision field compatible with a scanning electron microscope

    International Nuclear Information System (INIS)

    Volodin, A.P.; Stepanyan, G.A.; Khajkin, M.S.; Ehdel'man, V.S.

    1989-01-01

    A scanning tunnel microscope (STM) with the 20μm vision field and 1nm resolution, designed to be compatible with a scanning electron microscope (SEM), is described. The sample scanning area is chosen within the 3x10mm limits with a 0.1-1μm step. The STM needle is moved automatically toward the sample surface from the maximum distance of 10mm until the tunneling current appears. Bimorphous elements of the KP-1 piezocorrector are used in the STM design. The device is installed on a table of SEM object holders

  9. Bone scanning in severe external otitis

    International Nuclear Information System (INIS)

    Levin, W.J.; Shary, J.H. III; Nichols, L.T.; Lucente, F.E.

    1986-01-01

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans with many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis

  10. Dielectric properties of polycrystalline Cu-Zn ferrites at microwave frequencies

    International Nuclear Information System (INIS)

    Lamani, Ashok R.; Jayanna, H.S.; Parameswara, P.; Somashekar, R.; Ramachander,; Rao, Ramchandra; Prasanna, G.D.

    2011-01-01

    Highlights: → Cu 1-x Zn x Fe 2 O 4 at different concentration are suitable for high frequency applications. → Dielectric properties are related with W-H plot. → The anisotropy due to the crystallite size effect is significant in change of dielectric constant. - Abstract: The real dielectric constant ε' and complex dielectric constant ε'' of Cu 1-x Zn x Fe 2 O 4 have been measured at room temperature in the high frequency range 1 MHz to 1.8 GHz. At low frequencies the dielectric loss is found to be constant up to 1.4 GHz and there is a sudden rise at 1.5 GHz. A qualitative explanation is given for the composition, frequency dependence of the dielectric constant and dielectric loss of Cu 1-x Zn x Fe 2 O 4 . These are correlated with the W-H plot which gives the information about change in the average crystal size and strain of the samples. The micro-morphological features of the samples were obtained by Scanning Electron Microscopy (SEM). The micrograph shows that the increase of the Zn content in Cu ferrite increases the grain size.

  11. Handbook of optical and laser scanning

    CERN Document Server

    Marshall, Gerald F

    2011-01-01

    From its initial publication titled Laser Beam Scanning in 1985 to Handbook of Optical and Laser Scanning, now in its second edition, this reference has kept professionals and students at the forefront of optical scanning technology. Carefully and meticulously updated in each iteration, the book continues to be the most comprehensive scanning resource on the market. It examines the breadth and depth of subtopics in the field from a variety of perspectives. The Second Edition covers: Technologies such as piezoelectric devices Applications of laser scanning such as Ladar (laser radar) Underwater

  12. Effects of Optimizing the Scan-Path on Scanning Keyboards with QWERTY-Layout for English Text.

    Science.gov (United States)

    Sandnes, Frode Eika; Medola, Fausto Orsi

    2017-01-01

    Scanning keyboards can be essential tools for individuals with reduced motor function. However, most research addresses layout optimization. Learning new layouts is time-consuming. This study explores the familiar QWERTY layout with alternative scanning paths intended for English text. The results show that carefully designed scan-paths can help QWERTY nearly match optimized layouts in performance.

  13. Axial Fan Blade Vibration Assessment under Inlet Cross-Flow Conditions Using Laser Scanning Vibrometry

    Directory of Open Access Journals (Sweden)

    Till Heinemann

    2017-08-01

    Full Text Available In thermal power plants equipped with air-cooled condensers (ACCs, axial cooling fans operate under the influence of ambient flow fields. Under inlet cross-flow conditions, the resultant asymmetric flow field is known to introduce additional harmonic forces to the fan blades. This effect has previously only been studied numerically or by using blade-mounted strain gauges. For this study, laser scanning vibrometry (LSV was used to assess fan blade vibration under inlet cross-flow conditions in an adapted fan test rig inside a wind tunnel test section. Two co-rotating laser beams scanned a low-pressure axial fan, resulting in spectral, phase-resolved surface vibration patterns of the fan blades. Two distinct operating points with flow coefficients of 0.17 and 0.28 were examined, with and without inlet cross-flow influence. While almost identical fan vibration patterns were found for both reference operating points, the overall blade vibration increased by 100% at the low fan flow rate as a result of cross-flow, and by 20% at the high fan flow rate. While numerically predicted natural frequency modes could be confirmed from experimental data as minor peaks in the vibration amplitude spectrum, they were not excited significantly by cross-flow. Instead, primarily higher rotation-rate harmonics were amplified; that is, a synchronous blade-tip flapping was strongly excited at the blade-pass frequency.

  14. Resonant frequency detection and adjustment method for a capacitive transducer with differential transformer bridge

    Energy Technology Data Exchange (ETDEWEB)

    Hu, M.; Bai, Y. Z., E-mail: abai@mail.hust.edu.cn; Zhou, Z. B., E-mail: zhouzb@mail.hust.edu.cn; Li, Z. X.; Luo, J. [MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2014-05-15

    The capacitive transducer with differential transformer bridge is widely used in ultra-sensitive space accelerometers due to their simple structure and high resolution. In this paper, the front-end electronics of an inductive-capacitive resonant bridge transducer is analyzed. The analysis result shows that the performance of this transducer depends upon the case that the AC pumping frequency operates at the resonance point of the inductive-capacitive bridge. The effect of possible mismatch between the AC pumping frequency and the actual resonant frequency is discussed, and the theoretical analysis indicates that the output voltage noise of the front-end electronics will deteriorate by a factor of about 3 due to either a 5% variation of the AC pumping frequency or a 10% variation of the tuning capacitance. A pre-scanning method to determine the actual resonant frequency is proposed followed by the adjustment of the operating frequency or the change of the tuning capacitance in order to maintain expected high resolution level. An experiment to verify the mismatching effect and the adjustment method is provided.

  15. Resonant frequency detection and adjustment method for a capacitive transducer with differential transformer bridge

    International Nuclear Information System (INIS)

    Hu, M.; Bai, Y. Z.; Zhou, Z. B.; Li, Z. X.; Luo, J.

    2014-01-01

    The capacitive transducer with differential transformer bridge is widely used in ultra-sensitive space accelerometers due to their simple structure and high resolution. In this paper, the front-end electronics of an inductive-capacitive resonant bridge transducer is analyzed. The analysis result shows that the performance of this transducer depends upon the case that the AC pumping frequency operates at the resonance point of the inductive-capacitive bridge. The effect of possible mismatch between the AC pumping frequency and the actual resonant frequency is discussed, and the theoretical analysis indicates that the output voltage noise of the front-end electronics will deteriorate by a factor of about 3 due to either a 5% variation of the AC pumping frequency or a 10% variation of the tuning capacitance. A pre-scanning method to determine the actual resonant frequency is proposed followed by the adjustment of the operating frequency or the change of the tuning capacitance in order to maintain expected high resolution level. An experiment to verify the mismatching effect and the adjustment method is provided

  16. Preoperative nuclear scans in patients with melanoma

    International Nuclear Information System (INIS)

    Au, F.C.; Maier, W.P.; Malmud, L.S.; Goldman, L.I.; Clark, W.H. Jr.

    1984-01-01

    One hundred forty-one liver scans, 137 brain scans, and 112 bone scans were performed in 192 patients with clinical Stage 1 melanoma. One liver scan was interpreted as abnormal; liver biopsy of that patient showed no metastasis. There were 11 suggestive liver scans; three of the patients with suggestive liver scans had negative liver biopsies. The remaining eight patients were followed from 4 to 6 years and none of those patients developed clinical evidence of hepatic metastases. All of the brain scans were normal. Five patients had suggestive bone scans and none of those patients had manifested symptoms of osseous metastases with a follow-up of 2 to 4.5 years. This study demonstrates that the use of preoperative liver, brain and bone scan in the evaluation of patients with clinical Stage 1 melanoma is virtually unproductive

  17. Gallium scans in myasthenia gravis

    International Nuclear Information System (INIS)

    Swick, H.M.; Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether 67 Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on 67 Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis

  18. Gallium scans in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Swick, H.M. (Univ. of Kentucky, Lexington); Preston, D.F.; McQuillen, M.P.

    1976-01-01

    A study was conducted to determine whether /sup 67/Ga scans could be used for the detection of thymomas and to investigate the activity of the thymus gland in patients with myasthenia gravis. Scans of the anterior mediastinum proved to be a reliable way to detect thymomas. The scans were positive in eight patients including three with myasthenia gravis and histologically proved thymomas, three others with severe myasthenia gravis and thymic tumors, and two with histologically proved thymomas not associated with myasthenia. Activity on /sup 67/Ga scans was not directly related to the increased activity of the thymus gland that is presumed to be associated with myasthenia gravis. (HLW)

  19. AlaScan: A Graphical User Interface for Alanine Scanning Free-Energy Calculations.

    Science.gov (United States)

    Ramadoss, Vijayaraj; Dehez, François; Chipot, Christophe

    2016-06-27

    Computation of the free-energy changes that underlie molecular recognition and association has gained significant importance due to its considerable potential in drug discovery. The massive increase of computational power in recent years substantiates the application of more accurate theoretical methods for the calculation of binding free energies. The impact of such advances is the application of parent approaches, like computational alanine scanning, to investigate in silico the effect of amino-acid replacement in protein-ligand and protein-protein complexes, or probe the thermostability of individual proteins. Because human effort represents a significant cost that precludes the routine use of this form of free-energy calculations, minimizing manual intervention constitutes a stringent prerequisite for any such systematic computation. With this objective in mind, we propose a new plug-in, referred to as AlaScan, developed within the popular visualization program VMD to automate the major steps in alanine-scanning calculations, employing free-energy perturbation as implemented in the widely used molecular dynamics code NAMD. The AlaScan plug-in can be utilized upstream, to prepare input files for selected alanine mutations. It can also be utilized downstream to perform the analysis of different alanine-scanning calculations and to report the free-energy estimates in a user-friendly graphical user interface, allowing favorable mutations to be identified at a glance. The plug-in also assists the end-user in assessing the reliability of the calculation through rapid visual inspection.

  20. Obstacles to Industrial Implementation of Scanning Systems

    Science.gov (United States)

    Anders Astrom; Olog Broman; John Graffman; Anders Gronlund; Armas Jappinene; Jari Luostarinen; Jan Nystrom; Daniel L. Schmoldt

    1998-01-01

    Initially the group discussed what is meant by scanning systems. An operational definition was adopted to consider scanning system in the current context to be nontraditional scanning. Where, traditional scanning is defined as scanning that has been industrially operational and relatively common for several years-a mature technology. For example,...

  1. Design of Electromagnetic Moving-coil type Voice Coil Motor for Scanning mirror of Barcode reader

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Bu Hyun; Lee, Jeong Woo; Shim, Hyun Ho; Park, Sang Goo [Hanbat National Univ., Daejeon (Korea, Republic of); Lee, Seung Yop [Sogang Univ., Seoul (Korea, Republic of)

    2016-01-15

    A voice coil actuator with moving coil type for scanning mirror system of barcode reader has been developed. The actuator has a simple structure including a magnet, a coil and a pin. The performance of the actuator is analyzed by a linearized theoretical model. And the dynamic performance of the proposed actuator is predicted through motor constant and restoring constant obtained by finite element simulations. The theoretical model was verified by the prototype which has 64 Hz resonance frequency and 60 deg reflecting angle. We also discovered that that 3 V input can make the actuator rotate over 61.8 deg reflecting angle at 50 Hz resonance frequency. The proposed actuator can simplify its driving configuration because of its implementation of open-loop control.

  2. Interesting bone scans - unusual findings

    International Nuclear Information System (INIS)

    Dobson, M.; Wadhwa, S.S.; Mansberg, R.; Fernandes, V.B.

    1997-01-01

    A 59-year-old female with carcinoma of the colon and known liver metastatic disease was referred for bone scan to evaluate for bone metastases. Although no bone metastases were found, there was abnormal uptake noted in the liver corresponding to a metastatic calcified lesion. The only other findings were of degenerative disease in the cervical spine, right shoulder and small joints of the hands. A 69-year-old male with carcinoma of the prostate and right side low back pain was referred for bone scan. No focal abnormalities to suggest metastatic disease were identified; findings within the cervical spine, lumber spine and knees were presumed secondary to degenerative disease. Intermittent pain persisted and the patient was referred for a repeat bone scan six months later. Previous scan findings of degenerative disease and no metastatic disease were confirmed; however, closer inspection revealed an enlarged right kidney with significant retention of tracer in the pelvicalyceal system suggesting possible obstruction. A Retrograde pyelogram was performed, and no obvious obstruction demonstrated. As bone scan findings were very suggestive of obstruction, a DTPA scan with lasix was performed showing a dilated right collecting system with no functional obstruction. Given the degree of dilation, it is possible that the patient experiences intermittent PUJ obstruction causing his symptoms. A 33-year-old male with insulin dependent diabetes mellitus and viral arthritis was referred for a bone scan. A three phase revealed increased uptake in the region of the knee and leR proximal tibia. Delayed whole body images revealed multiple focal areas of osteoblastic activity in the leR tibia. Abnormal uptake was also seen in the upper third of the leR femur. The remainder of the skeletal survey was normal. X-ray correlation of the leR tibia and femoral findings was undertaken. Combinating unilateral changes on bone scan and X-ray although very suggestive of sclerotic polyostotic

  3. An electrostatic scanning micromirror with diaphragm mirror plate and diamond-shaped reinforcement frame

    Science.gov (United States)

    Ji, Chang-Hyeon; Choi, Moongoo; Kim, Sang-Cheon; Lee, See-Hyung; Kim, Seong-Hyok; Yee, Youngjoo; Bu, Jong-Uk

    2006-05-01

    We present the design, fabrication and measurement results of a comb-driven electrostatic scanning micromirror. Instead of a conventional micromirror having uniform thickness across the entire reflective surface, a diaphragm mirror plate supported by an array of diamond-shaped frame structures is fabricated monolithically. The fabrication process is a simple sequence of silicon deep etch processes on both sides of the silicon-on-insulator (SOI) substrate without the substrate bonding process. The micromirror is fabricated on the device layer of the substrate. The mirror plate undergoes a rotational motion by an electrostatic force between the movable comb electrodes connected to the micromirror and stationary comb electrode formed on the handle wafer. A scanning micromirror with a 10 µm thick diaphragm mirror plate, having a planar dimension of 1.5 × 1.5 mm2, supported by an array of 110 µm thick rhombic support frames, was fabricated and tested. A mechanical deflection angle of 8.5° at a resonance frequency of 19.55 kHz and a pressure of 7 mTorr was obtained. A prototype of the raster scanning laser projection display system was developed using the fabricated micromirror as the horizontal scanner and a galvanomirror as the vertical scanner, respectively.

  4. MULTISPECTRAL AIRBORNE LASER SCANNING - A NEW TREND IN THE DEVELOPMENT OF LIDAR TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Bakuła Krzysztof

    2015-12-01

    Full Text Available Airborne laser scanning (ALS is the one of the most accurate remote sensing techniques for data acquisition where the terrain and its coverage is concerned. Modern scanners have been able to scan in two or more channels (frequencies of the laser recently. This gives the rise to the possibility of obtaining diverse information about an area with the different spectral properties of objects. The paper presents an example of a multispectral ALS system - Titan by Optech - with the possibility of data including the analysis of digital elevation models accuracy and data density. As a result of the study, the high relative accuracy of LiDAR acquisition in three spectral bands was proven. The mean differences between digital terrain models (DTMs were less than 0.03 m. The data density analysis showed the influence of the laser wavelength. The points clouds that were tested had average densities of 25, 23 and 20 points per square metre respectively for green (G, near-infrared (NIR and shortwave-infrared (SWIR lasers. In this paper, the possibility of the generation of colour composites using orthoimages of laser intensity reflectance and its classification capabilities using data from airborne multispectral laser scanning for land cover mapping are also discussed and compared with conventional photogrammetric techniques.

  5. The utility of bone scans in rheumatology

    International Nuclear Information System (INIS)

    Duncan, I.; Dorai-Raj, A.; Khoo, K.; Tymans, K.; Brook, A.

    1997-01-01

    Full text: Introduction: Bone scans are the commonest diagnostic imaging services requested by Australian rheumatologists. Medicare figures suggest that an average rheumatologist orders about $50 000 (AUS) of bone scans annually. Aims: To ascertain the reasons why rheumatologists request bone scans and how it affects their patient management. Methods: A two-part prospective survey was administered before and after every bone scan ordered by four rheumatologists over a six-month period in 1996. Results: A total of 136 bone scans were requested (66.2% whole body; 33.8% regional; 6% SPECT). The primary indications for scanning were (1) to confirm a clinical diagnosis (38%); (2) to exclude a diagnosis (34%); (3) to localize site of pain (17%); and (4) to assist in management (6%). The common diseases that rheumatologists were attempting to confirm/exclude with bone scanning were inflammatory arthritis, malignancy, and fracture. However, the commonest provisional and final diagnosis was soft tissue rheumatism (18%) followed by inflammatory arthritis (15%) and osteoarthritis (11%). In 24% of patients with a provisional diagnosis of soft tissue rheumatism the diagnosis was changed by the bone scan. The scan was successful in excluding a diagnosis in 88 per cent where this was the primary indication for the test. It was successful in confirming a diagnosis in 79 per cent where this was the primary indication. In 32 per cent the bone scan altered the clinical diagnosis and in 43 per cent it altered management. The bone scan result prevented further investigations in 60 per cent. Conclusions: The commonest pre-scan and post-scan diagnosis is soft tissue rheumatism. Rheumatologists predominantly request bone scanning to confirm or exclude their clinical suspicion of inflammatory arthritis, malignancy, and fracture. Bone scans were successful in achieving these objectives in at least 79 per cent of cases

  6. Novel Implementations of Wideband Tightly Coupled Dipole Arrays for Wide-Angle Scanning

    Science.gov (United States)

    Yetisir, Ersin

    Ultra-wideband (UWB) antennas and arrays are essential for high data rate communications and for addressing spectrum congestion. Tightly coupled dipole arrays (TCDAs) are of particular interest due to their low-profile, bandwidth and scanning range. But existing UWB (>3:1 bandwidth) arrays still suffer from limited scanning, particularly at angles beyond 45° from broadside. Almost all previous wideband TCDAs have employed dielectric layers above the antenna aperture to improve scanning while maintaining impedance bandwidth. But even so, these UWB arrays have been limited to no more than 60° away from broadside. In this work, we propose to replace the dielectric superstrate with frequency selective surfaces (FSS). In effect, the FSS is used to create an effective dielectric layer placed over the antenna array. FSS also enables anisotropic responses and more design freedom than conventional isotropic dielectric substrates. Another important aspect of the FSS is its ease of fabrication and low weight, both critical for mobile platforms (e.g. unmanned air vehicles), especially at lower microwave frequencies. Specifically, it can be fabricated using standard printed circuit technology and integrated on a single board with active radiating elements and feed lines. In addition to the FSS superstrate, a modified version of the stripline-based folded Marchand balun is presented. As usual the balun serves to match the 50Ω coaxial cable to the high input impedance ( 200Ω) at the terminals of array elements. Doing so, earlier Wilkinson power dividers, which degrade efficiency during E-plane scanning, are eliminated. To verify the proposed array concept, 12x12 TCDA prototype was fabricated using the modified balun and the new FSS superstrate layer. The design and experimental data showed an impedance bandwidth of 6.1:1 with VSWR<3.2. The latter VSWR was achieved even when scanning down to +/-60° in the H-plane, +/-70° in the D-plane and +/-75° in the E-plane. All array

  7. Near-Field Microwave Magnetic Nanoscopy of Superconducting Radio Frequency Cavity Materials

    OpenAIRE

    Tai, Tamin; Ghamsari, Behnood G.; Bieler, Thomas R.; Tan, Teng; Xi, X. X.; Anlage, Steven M.

    2013-01-01

    A localized measurement of the RF critical field on superconducting radio frequency (SRF) cavity materials is a key step to identify specific defects that produce quenches of SRF cavities. Two new measurements are performed to demonstrate these capabilities with a novel near-field scanning probe microwave microscope. The first is a third harmonic nonlinear measurement on a high Residual- Resistance-Ratio bulk Nb sample showing strong localized nonlinear response for the first time, with surfa...

  8. Scanning ARM Cloud Radars. Part II: Data Quality Control and Processing

    Energy Technology Data Exchange (ETDEWEB)

    Kollias, Pavlos; Jo, Ieng; Borque, Paloma; Tatarevic, Aleksandra; Lamer, Katia; Bharadwaj, Nitin; Widener, Kevin B.; Johnson, Karen L.; Clothiaux, Eugene E.

    2014-03-01

    The Scanning ARM Cloud Radars (SACR’s) are the primary instruments for documenting the four-dimensional structure and evolution of clouds within a 20-30 km radius from the ARM fixed and mobile sites. Here, the post-processing of the calibrated SACR measurements is discussed. First, a feature mask algorithm that objectively determines the presence of significant radar returns is described. The feature mask algorithm is based on the statistical properties of radar receiver noise. It accounts for atmospheric emission and is applicable even for SACR profiles with few or no signal-free range gates. Using the nearest-in-time atmospheric sounding, the SACR radar reflectivities are corrected for gaseous attenuation (water vapor and oxygen) using a line-by-line absorption model. Despite having a high pulse repetition frequency, the SACR has a narrow Nyquist velocity limit and thus Doppler velocity folding is commonly observed. An unfolding algorithm that makes use of a first guess for the true Doppler velocity using horizontal wind measurements from the nearest sounding is described. The retrieval of the horizontal wind profile from the HS-RHI SACR scan observations and/or nearest sounding is described. The retrieved horizontal wind profile can be used to adaptively configure SACR scan strategies that depend on wind direction. Several remaining challenges are discussed, including the removal of insect and second-trip echoes. The described algorithms significantly enhance SACR data quality and constitute an important step towards the utilization of SACR measurements for cloud research.

  9. Scanning tunneling microscopic images and scanning tunneling spectra for coupled rectangular quantum corrals

    International Nuclear Information System (INIS)

    Mitsuoka, Shigenori; Tamura, Akira

    2011-01-01

    Assuming that an electron confined by double δ-function barriers lies in a quasi-stationary state, we derived eigenstates and eigenenergies of the electron. Such an electron has a complex eigenenergy, and the imaginary part naturally leads to the lifetime of the electron associated with tunneling through barriers. We applied this point of view to the electron confined in a rectangular quantum corral (QC) on a noble metal surface, and obtained scanning tunneling microscopic images and a scanning tunneling spectrum consistent with experimental ones. We investigated the electron states confined in coupled QCs and obtained the coupled states constructed with bonding and anti-bonding states. Using those energy levels and wavefunctions we specified scanning tunneling microscope (STM) images and scanning tunneling spectra (STS) for the doubly and triply coupled QCs. In addition we pointed out the feature of resonant electron states associated with the same QCs at both ends of the triply coupled QCs.

  10. A review of patient dose and optimisation methods in adult and paediatric CT scanning

    International Nuclear Information System (INIS)

    Dougeni, E.; Faulkner, K.; Panayiotakis, G.

    2012-01-01

    Highlights: ► CT scanning frequency has grown with the development of new clinical applications. ► Up to 32-fold dose variation was observed for similar type of procedures. ► Scanning parameters should be optimised for patient size and clinical indication. ► Cancer risks knowledge amongst physicians of certain specialties was poor. ► A significant number of non-indicated CT scans could be eliminated. - Abstract: An increasing number of publications and international reports on computed tomography (CT) have addressed important issues on optimised imaging practice and patient dose. This is partially due to recent technological developments as well as to the striking rise in the number of CT scans being requested. CT imaging has extended its role to newer applications, such as cardiac CT, CT colonography, angiography and urology. The proportion of paediatric patients undergoing CT scans has also increased. The published scientific literature was reviewed to collect information regarding effective dose levels during the most common CT examinations in adults and paediatrics. Large dose variations were observed (up to 32-fold) with some individual sites exceeding the recommended dose reference levels, indicating a large potential to reduce dose. Current estimates on radiation-related cancer risks are alarming. CT doses account for about 70% of collective dose in the UK and are amongst the highest in diagnostic radiology, however the majority of physicians underestimate the risk, demonstrating a decreased level of awareness. Exposure parameters are not always adjusted appropriately to the clinical question or to patient size, especially for children. Dose reduction techniques, such as tube-current modulation, low-tube voltage protocols, prospective echocardiography-triggered coronary angiography and iterative reconstruction algorithms can substantially decrease doses. An overview of optimisation studies is provided. The justification principle is discussed along

  11. CAMAC gamma ray scanning system

    International Nuclear Information System (INIS)

    Moss, C.E.; Pratt, J.C.; Shunk, E.R.

    1981-01-01

    A flexible gamma-ray scanning system, based on a LeCroy 3500 multichannel analyzer and CAMAC modules, is described. The system is designed for making simultaneous passive and active scans of objects of interest to nuclear safeguards. The scanner is a stepping-motor-driven carriage; the detectors, a bismuth-germanate scintillator and a high-purity germanium detector. A total of sixteen peaks in the two detector-produced spectra can be integrated simultaneously, and any scan can be viewed during data acquisition. For active scanning, the 2615-keV gamma-ray line from a 232 U source and the 4439-keV gamma-ray line from 9 Be(α,n) 12 C were selected. The system can be easily reconfigured to accommodate up to seven detectors because it is based on CAMAC modules and FORTRAN. The system is designed for field use and is easily transported. Examples of passive and active scans are presented

  12. Security scanning at 35 GHz

    Science.gov (United States)

    Anderton, Rupert N.; Appleby, Roger; Coward, Peter R.; Kent, P. J.; Price, Sean; Sinclair, Gordon N.; Wasley, Matthew R. M.

    2001-08-01

    It has been known for some time that millimeter waves can pas through clothing. In short range applications such as in the scanning of people for security purposes, operating at Ka band can be an advantage. The penetration through clothing is increased and the cost of the equipment when compared to operation at W band. In this paper a Ka band mechanically scanned imager designed for security scanning is discussed. This imager is based on the folded conical scan technology previously reported. It is constructed from low cost materials such as polystyrene and printed circuit board. The trade off between image spatial resolution and the number of receivers will be described and solutions, which minimize this number discussed.

  13. Comparison of thallium-201 scan and Tc-99m sestamibi scan in the differential diagnosis of breast mass

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Won, Kyu Jang; Lee, Hyung Woo; Lee, Soon Jung [College of Medicine, Yonsei Univ., Seoul (Korea, Republic of)

    1999-02-01

    We performed this study to compare Tl-201 and Tc-99m MIBI scans for the differentiation of malignant from benign breast mass. Thirty-eight female patients underwent Tl-201 breast scan and thirty-two of them also underwent Tc-99m MIBI scan of the breast. After intravenous injection of 74-111 MBq of Tl-201, early (10 minutes) and delayed (3 hours) images were obtained. Then, 555-740 MBq of Tc-99m MIBI was injected and images after 30 minutes were obtained. We compared Tl-201 and Tc-99m MIBI scans with pathologic results. Twenty-three patients were confirmed to have infiltrating duct carcinoma and fifteen patients to have benign breast mass by excisonal biopsy. The sensitivity of early and delayed Tl-201 scan and Tc-99m MIBI scan in the detection of malignant breast lesion were 100% (23/23), 82% (18/22), and 90% (18/20), respectively. The sensitivity of early Tl-201 scan was significantly higher than that of delayed Tl-201 scan, (p<0.05). The specificity of early and delayed Tl-201 scan and Tc-99m MIBI scan were 73% (11/15), 73% (11/15) and 83% (10/12), respectively (p: not significant). Three patients out of nine with fibroadenoma and one patient with atypical duct hyperplasia were false positive in both early and delayed Tl-201 scans. The size of fibroadenoma with false positive in early and delayed Tl-201 scan (4 cases) was larger than that of 11 fibroadenoma with true negative scan (p<0.01). Metastatic axillary lymph node involvement was present in fifteen patients. The sensitivity to detect metastatic nodes was 38% (5/13) for early Tl-201 images, 15% (2/13) for delayed Tl-201 images, 58% (7/12) for Tc-99m MIBI planar images and 67% (4/6) for Tc-99m MIBI SPECT. The sensitivity of Tc-99m MIBI planar or SPECT was significantly higher than that of delayed Tl-201 images (p<0.05). Early Tl-201 and Tc-99m MIBI scan are useful noninvasive methods to differentiate malignant from benign mass of breast. Tc-99m MIBI scan was sensitive in detecting axillary lymph node

  14. Three phase bone scan , Ga-67 and Tc-99m nanocoll scan in detection of osteomyelitis caused by war injuries

    International Nuclear Information System (INIS)

    Banek, T.; Reljica-Kostic, Z.; Kurnik, G.

    1994-01-01

    Thirty three injured soldiers were surgically treated because of pierce wounds of extremities. Treatment was either osteosynthesis or external fixation. Two to four weeks post treatment clinical signs of osteomyelitis appeared. X-ray was negative in all patients. Three-phase bone scan was performed in order to establish diagnosis. Bone scan was positive in all patients. For 11 patients only bone scan was sufficient for decision of further treatment. In 22 patients Ga-67 or Tc-99m- nanocoll or both examinations were performed on surgeon's request. In 2 patients out of 5 with additional Ga-67 scan, Ga-67 scan showed more lesions than it was seen on bone scan. In 3 patients out of 5 with additional Tc-99m-nanocoll scan, Tc-99m-nanocoll scan showed more lesions than it was seen on bone scan. In 12 patients with positive bone scan and negative or unclear Ga-67, Tc-99m-nanocoll scan was performed. In 5 out of 12 patients Tc-99m- nanocoll scan established diagnosis in others confirmed finding on bone and Ga-67 scan. Our results showed that in one third of our causes bone scan was sufficient for diagnosing of osteomyelitis caused by war injuries. In selected cases where bone scan was not sufficient for diagnosis and decision for treatment Tc-99m-nanocoll was more sensitive than Ga-67. In our experience three-phase bone scan is more sensitive than Ga-67. In our opinion three-phase bone scan is the method of choice for diagnosing osteomyelitis in war situation with a lot of casualties. (author)

  15. Optical frequency measurements of 6s 2S1/2-6p 2P3/2 transition in a 133Cs atomic beam using a femtosecond laser frequency comb

    International Nuclear Information System (INIS)

    Gerginov, V.; Tanner, C.E.; Diddams, S.; Bartels, A.; Hollberg, L.

    2004-01-01

    Optical frequencies of the hyperfine components of the D 2 line in 133 Cs are determined using high-resolution spectroscopy and a femtosecond laser frequency comb. A narrow-linewidth probe laser excites the 6s 2 S 1/2 (F=3,4)→6p 2 P 3/2 (F=2,3,4,5) transition in a highly collimated atomic beam. Fluorescence spectra are taken by scanning the laser frequency over the excited-state hyperfine structure. The laser optical frequency is referenced to a Cs fountain clock via a reference laser and a femtosecond laser frequency comb. A retroreflected laser beam is used to estimate and minimize the Doppler shift due to misalignment between the probe laser and the atomic beam. We achieve an angular resolution on the order of 5x10 -6 rad. The final uncertainties (∼±5 kHz) in the frequencies of the optical transitions are a factor of 20 better than previous results [T. Udem et al., Phys. Rev. A 62, 031801 (2000).]. We find the centroid of the 6s 2 S 1/2 →6p 2 P 3/2 transition to be f D2 =351 725 718.4744(51) MHz

  16. Method and apparatus to debug an integrated circuit chip via synchronous clock stop and scan

    Science.gov (United States)

    Bellofatto, Ralph E [Ridgefield, CT; Ellavsky, Matthew R [Rochester, MN; Gara, Alan G [Mount Kisco, NY; Giampapa, Mark E [Irvington, NY; Gooding, Thomas M [Rochester, MN; Haring, Rudolf A [Cortlandt Manor, NY; Hehenberger, Lance G [Leander, TX; Ohmacht, Martin [Yorktown Heights, NY

    2012-03-20

    An apparatus and method for evaluating a state of an electronic or integrated circuit (IC), each IC including one or more processor elements for controlling operations of IC sub-units, and each the IC supporting multiple frequency clock domains. The method comprises: generating a synchronized set of enable signals in correspondence with one or more IC sub-units for starting operation of one or more IC sub-units according to a determined timing configuration; counting, in response to one signal of the synchronized set of enable signals, a number of main processor IC clock cycles; and, upon attaining a desired clock cycle number, generating a stop signal for each unique frequency clock domain to synchronously stop a functional clock for each respective frequency clock domain; and, upon synchronously stopping all on-chip functional clocks on all frequency clock domains in a deterministic fashion, scanning out data values at a desired IC chip state. The apparatus and methodology enables construction of a cycle-by-cycle view of any part of the state of a running IC chip, using a combination of on-chip circuitry and software.

  17. Polydyne displacement interferometer using frequency-modulated light

    Science.gov (United States)

    Arablu, Masoud; Smith, Stuart T.

    2018-05-01

    A radio-frequency Frequency-Modulated (FM) signal is used to diffract a He-Ne laser beam through an Acousto-Optic Modulator (AOM). Due to the modulation of the FM signal, the measured spectra of the diffracted beams comprise a series of phase-synchronized harmonics that have exact integer frequency separation. The first diffraction side-beam emerging from the AOM is selected by a slit to be used in a polydyne displacement interferometer in a Michelson interferometer topology. The displacement measurement is derived from the phase measurement of selected modulation harmonic pairs. Individual harmonic frequency amplitudes are measured using discrete Fourier transform applied to the signal from a single photodetector. Phase signals are derived from the changes in the amplitudes of different harmonic pairs (typically odd-even pairs) with the phase being extracted using a standard quadrature method. In this study, two different modulation frequencies of 5 and 10 kHz are used at different modulation depths. The measured displacements by different harmonic pairs are compared with a commercial heterodyne interferometer being used as a reference for these studies. Measurements obtained from five different harmonic pairs when the moving mirror of the interferometer is scanned over ranges up to 10 μm all show differences of less than 50 nm from the reference interferometer measurements. A drift test was also used to evaluate the differences between the polydyne interferometer and reference measurements that had different optical path lengths of approximately 25 mm and 50 mm, respectively. The drift test results indicate that about half of the differences can be attributed to temperature, pressure, and humidity variations. Other influences include Abbe and thermal expansion effects. Rough magnitude estimates using simple models for these two effects can account for remaining observed deviations.

  18. The Scanning Theremin Microscope: A Model Scanning Probe Instrument for Hands-On Activities

    Science.gov (United States)

    Quardokus, Rebecca C.; Wasio, Natalie A.; Kandel, S. Alex

    2014-01-01

    A model scanning probe microscope, designed using similar principles of operation to research instruments, is described. Proximity sensing is done using a capacitance probe, and a mechanical linkage is used to scan this probe across surfaces. The signal is transduced as an audio tone using a heterodyne detection circuit analogous to that used in…

  19. Frequency-Specific Alternations in the Amplitude of Low-Frequency Fluctuations in Chronic Tinnitus

    Directory of Open Access Journals (Sweden)

    Yu-Chen eChen

    2015-10-01

    Full Text Available Tinnitus, a phantom ringing, buzzing or hissing sensation with potentially debilitating consequences, is thought to arise from aberrant spontaneous neural activity at one or more sites within the central nervous system; however, the location and specific features of these oscillations are poorly understood with respect to specific tinnitus features. Recent resting-state functional magnetic resonance imaging (fMRI studies suggest that aberrant fluctuations in spontaneous low-frequency oscillations (LFO of the blood oxygen level-dependent (BOLD signal may be an important factor in chronic tinnitus; however, the role that frequency-specific components of LFO play in subjective tinnitus remains unclear. A total of 39 chronic tinnitus patients and 41 well-matched healthy controls participated in the resting-state fMRI scans. The LFO amplitudes were investigated using the amplitude of low-frequency fluctuation (ALFF and fractional ALFF (fALFF in two different frequency bands (slow-4: 0.027-0.073 Hz and slow-5: 0.01-0.027 Hz. We observed significant differences between tinnitus patients and normal controls in ALFF/fALFF in the two bands (slow-4 and slow-5 in several brain regions including the superior frontal gyrus (SFG, inferior frontal gyrus, middle temporal gyrus, angular gyrus, supramarginal gyrus, and middle occipital gyrus. Across the entire subject pool, significant differences in ALFF/fALFF between the two bands were found in the midbrain, basal ganglia, hippocampus and cerebellum (Slow 4>Slow 5, and in the middle frontal gyrus, supramarginal gyrus, posterior cingulate cortex, and precuneus (Slow 5>Slow 4. We also observed significant interaction between frequency bands and patient groups in the orbitofrontal gyrus. Furthermore, tinnitus distress was positively correlated with the magnitude of ALFF in right SFG and the magnitude of fALFF slow-4 band in left SFG, whereas tinnitus duration was positively correlated with the magnitude of ALFF in

  20. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  1. Scanning fiber microdisplay: design, implementation, and comparison to MEMS mirror-based scanning displays.

    Science.gov (United States)

    Khayatzadeh, Ramin; Civitci, Fehmi; Ferhanoglu, Onur; Urey, Hakan

    2018-03-05

    In this study, we propose a compact, lightweight scanning fiber microdisplay towards virtual and augmented reality applications. Our design that is tailored as a head-worn-display simply consists of a four-quadrant piezoelectric tube actuator through which a fiber optics cable is extended and actuated, and a reflective (or semi-reflective) ellipsoidal surface that relays the moving tip of the fiber onto the viewer's retina. The proposed display, offers significant advantages in terms of architectural simplicity, form-factor, fabrication complexity and cost over other fiber scanner and MEMS mirror counterparts towards practical realization. We demonstrate the display of various patterns with ∼VGA resolution and further provide analytical formulas for mechanical and optical constraints to compare the performance of the proposed scanning fiber microdisplay with that of MEMS mirror-based microdisplays. Also we discuss the road steps towards improving the performance of the proposed scanning fiber microdisplay to high-definition video formats (such as HD1440), which is beyond what has been achieved by MEMS mirror based laser scanning displays.

  2. Analysis on optical heterodyne frequency error of full-field heterodyne interferometer

    Science.gov (United States)

    Li, Yang; Zhang, Wenxi; Wu, Zhou; Lv, Xiaoyu; Kong, Xinxin; Guo, Xiaoli

    2017-06-01

    The full-field heterodyne interferometric measurement technology is beginning better applied by employing low frequency heterodyne acousto-optical modulators instead of complex electro-mechanical scanning devices. The optical element surface could be directly acquired by synchronously detecting the received signal phases of each pixel, because standard matrix detector as CCD and CMOS cameras could be used in heterodyne interferometer. Instead of the traditional four-step phase shifting phase calculating, Fourier spectral analysis method is used for phase extracting which brings lower sensitivity to sources of uncertainty and higher measurement accuracy. In this paper, two types of full-field heterodyne interferometer are described whose advantages and disadvantages are also specified. Heterodyne interferometer has to combine two different frequency beams to produce interference, which brings a variety of optical heterodyne frequency errors. Frequency mixing error and beat frequency error are two different kinds of inescapable heterodyne frequency errors. In this paper, the effects of frequency mixing error to surface measurement are derived. The relationship between the phase extraction accuracy and the errors are calculated. :: The tolerance of the extinction ratio of polarization splitting prism and the signal-to-noise ratio of stray light is given. The error of phase extraction by Fourier analysis that caused by beat frequency shifting is derived and calculated. We also propose an improved phase extraction method based on spectrum correction. An amplitude ratio spectrum correction algorithm with using Hanning window is used to correct the heterodyne signal phase extraction. The simulation results show that this method can effectively suppress the degradation of phase extracting caused by beat frequency error and reduce the measurement uncertainty of full-field heterodyne interferometer.

  3. Scanning holograms

    International Nuclear Information System (INIS)

    Natali, S.

    1984-01-01

    This chapter reports on the scanning of 1000 holograms taken in HOBC at CERN. Each hologram is triggered by an interaction in the chamber, the primary particles being pions at 340 GeV/c. The aim of the experiment is the study of charm production. The holograms, recorded on 50 mm film with the ''in line'' technique, can be analyzed by shining a parallel expanded laser beam through the film, obtaining immediately above it the real image of the chamber which can then be scanned and measured with a technique half way between emulsions and bubble chambers. The results indicate that holograms can be analyzed as quickly and reliably as in other visual techniques and that to them is open the same order of magnitude of large scale experiments

  4. Effects of scanning and eliminating paper-based medical records on hospital physicians' clinical work practice.

    Science.gov (United States)

    Laerum, Hallvard; Karlsen, Tom H; Faxvaag, Arild

    2003-01-01

    It is not automatically given that the paper-based medical record can be eliminated after the introduction of an electronic medical record (EMR) in a hospital. Many keep and update the paper-based counterpart, and this limits the use of the EMR system. The authors have evaluated the physicians' clinical work practices and attitudes toward a system in a hospital that has eliminated the paper-based counterpart using scanning technology. Combined open-ended interviews (8 physicians) and cross-sectional survey (70 physicians) were conducted and compared with reference data from a previous national survey (69 physicians from six hospitals). The hospitals in the reference group were using the same EMR system without the scanning module. The questionnaire (English translation available as an online data supplement at ) covered frequency of use of the EMR system for 19 defined tasks, ease of performing them, and user satisfaction. The interviews were open-ended. The physicians routinely used the system for nine of 11 tasks regarding retrieval of patient data, which the majority of the physicians found more easily performed than before. However, 22% to 25% of the physicians found retrieval of patient data more difficult, particularly among internists (33%). Overall, the physicians were equally satisfied with the part of the system handling the regular electronic data as that of the physicians in the reference group. They were, however, much less satisfied with the use of scanned document images than that of regular electronic data, using the former less frequently than the latter. Scanning and elimination of the paper-based medical record is feasible, but the scanned document images should be considered an intermediate stage toward fully electronic medical records. To our knowledge, this is the first assessment from a hospital in the process of completing such a scanning project.

  5. Hi-Res scan mode in clinical MDCT systems: Experimental assessment of spatial resolution performance.

    Science.gov (United States)

    Cruz-Bastida, Juan P; Gomez-Cardona, Daniel; Li, Ke; Sun, Heyi; Hsieh, Jiang; Szczykutowicz, Timothy P; Chen, Guang-Hong

    2016-05-01

    The introduction of a High-Resolution (Hi-Res) scan mode and another associated option that combines Hi-Res mode with the so-called High Definition (HD) reconstruction kernels (referred to as a Hi-Res/HD mode in this paper) in some multi-detector CT (MDCT) systems offers new opportunities to increase spatial resolution for some clinical applications that demand high spatial resolution. The purpose of this work was to quantify the in-plane spatial resolution along both the radial direction and tangential direction for the Hi-Res and Hi-Res/HD scan modes at different off-center positions. A technique was introduced and validated to address the signal saturation problem encountered in the attempt to quantify spatial resolution for the Hi-Res and Hi-Res/HD scan modes. Using the proposed method, the modulation transfer functions (MTFs) of a 64-slice MDCT system (Discovery CT750 HD, GE Healthcare) equipped with both Hi-Res and Hi-Res/HD modes were measured using a metal bead at nine different off-centered positions (0-16 cm with a step size of 2 cm); at each position, both conventional scans and Hi-Res scans were performed. For each type of scan and position, 80 repeated acquisitions were performed to reduce noise induced uncertainties in the MTF measurements. A total of 15 reconstruction kernels, including eight conventional kernels and seven HD kernels, were used to reconstruct CT images of the bead. An ex vivo animal study consisting of a bone fracture model was performed to corroborate the MTF results, as the detection of this high-contrast and high frequency task is predominantly determined by spatial resolution. Images of this animal model generated by different scan modes and reconstruction kernels were qualitatively compared with the MTF results. At the centered position, the use of Hi-Res mode resulted in a slight improvement in the MTF; each HD kernel generated higher spatial resolution than its counterpart conventional kernel. However, the MTF along the

  6. Design and development of ITER high-frequency magnetic sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Y., E-mail: Yunxing.Ma@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Fircroft Engineering, Lingley House, 120 Birchwood Point, Birchwood Boulevard, Warrington, WA3 7QH (United Kingdom); Vayakis, G. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Begrambekov, L.B. [National Research Nuclear University (MEPhI), 115409, Moscow, Kashirskoe shosse 31 (Russian Federation); Cooper, J.-J. [Culham Centre for Fusion Energy (CCFE), Abingdon, Oxfordshire OX14 3DB (United Kingdom); Duran, I. [IPP Prague, Za Slovankou 1782/3, 182 00 Prague 8 (Czech Republic); Hirsch, M.; Laqua, H.P. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Moreau, Ph. [CEA Cadarache, 13108 Saint Paul lez Durance Cedex (France); Oosterbeek, J.W. [Eindhoven University of Technology (TU/e), PO Box 513, 5600 MB Eindhoven (Netherlands); Spuig, P. [CEA Cadarache, 13108 Saint Paul lez Durance Cedex (France); Stange, T. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Walsh, M. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-15

    Highlights: • ITER high-frequency magnetic sensor system has been designed. • Prototypes have been successfully manufactured. • Manufactured prototypes have been tested in various labs. • Test results experimentally validated the design. - Abstract: High-frequency (HF) inductive magnetic sensors are the primary ITER diagnostic set for Toroidal Alfvén Eigenmodes (TAE) detection, while they also supplement low-frequency MHD and plasma equilibrium measurements. These sensors will be installed on the inner surface of ITER vacuum vessel, operated in a harsh environment with considerable neutron/nuclear radiation and high thermal load. Essential components of the HF sensor system, including inductive coil, electron cyclotron heating (ECH) shield, electrical cabling and termination load, have been designed to meet ITER measurement requirements. System performance (e.g. frequency response, thermal conduction) has been assessed. A prototyping campaign was initiated to demonstrate the manufacturability of the designed components. Prototypes have been produced according to the specifications. A series of lab tests have been performed to examine assembly issues and validate electrical and thermo-mechanical aspects of the design. In-situ microwave radiation test has been conducted in the MISTRAL test facility at IPP-Greifswald to experimentally examine the microwave shielding efficiency and structural integrity of the ECH shield. Low-power microwave attenuation measurement and scanning electron microscopic inspection were conducted to probe and examine the quality of the metal coating on the ECH shield.

  7. Comparison of MRI fast SPGR single slice scan and continuous dynamic scan in patients with obstructive sleep apnea-hypopnea syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xinyu [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: myginny2@sina.com; Yang Xue [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: yangxueqyfy@126.com; Hua Hui [Department of Otorhinolaryngology-Head and Neck Surgery, Medical School Hospital of Qingdao University, Qingdao (China)], E-mail: huahuisky@163.com; Chen Jingjing [Department of Radiology, Medical School Hospital of Qingdao University, 16 Jiangsu Road, Qingdao 266003 (China)], E-mail: chenjingjingsky@126.com

    2009-07-15

    Objective: To evaluate the application value of MRI fast SPGR single slice scan in patients with obstructive sleep apnea-hypopnea syndrome when comparing the images between fast SPGR single slice scan and continuous dynamic scan. Methods: Eighteen patients with obstructive sleep apnea-hypopnea syndrome were examined by fast SPGR single slice scan and continuous dynamic scan in turn. Fast SPGR single slice scans were conducted when the phases of apnea, inspiration and expiration appeared on the respiratory wave of the subjects. Fast SPGR continuous dynamic scans were conducted when the patients were awake and apneic. The scan planes were median sagittal plane and axial planes (the slice of middle part of palate, the slice of inferior part of palate, the slice of middle part of lingual root and the slice of 0.5 cm beneath the free margin of epiglottis). The obstructed sites and the cross-sectional areas of upper airway were compared between the two scan methods. Results: Seven cases showed complete obstruction at the narrowest sites of upper airway when apnea appeared; eleven cases showed marked decrease in cross-sectional areas at the narrowest sites compared with the areas when the patients were awake; two cases manifested multiple narrowness. The obstructed sites showed by the two scan methods were same. The difference of the cross-sectional areas of upper airway between the two scan methods was insignificant (P > 0.05). Conclusion: Fast SPGR single slice scan can accurately reflect the obstructed sites of upper airway when the breath breaks off and is the complementary method of continuous dynamic scan. Sometimes, single slice scan can replace continuous dynamic scan.

  8. A novel MR-compatible sensor to assess active medical device safety: stimulation monitoring, rectified radio frequency pulses, and gradient-induced voltage measurements.

    Science.gov (United States)

    Barbier, Thérèse; Aissani, Sarra; Weber, Nicolas; Pasquier, Cédric; Felblinger, Jacques

    2018-03-30

    To evaluate the function of an active implantable medical device (AIMD) during magnetic resonance imaging (MRI) scans. The induced voltages caused by the switching of magnetic field gradients and rectified radio frequency (RF) pulse were measured, along with the AIMD stimulations. An MRI-compatible voltage probe with a bandwidth of 0-40 kHz was designed. Measurements were carried out both on the bench with an overvoltage protection circuit commonly used for AIMD and with a pacemaker during MRI scans on a 1.5 T (64 MHz) MR scanner. The sensor exhibits a measurement range of ± 15 V with an amplitude resolution of 7 mV and a temporal resolution of 10 µs. Rectification was measured on the bench with the overvoltage protection circuit. Linear proportionality was confirmed between the induced voltage and the magnetic field gradient slew rate. The pacemaker pacing was recorded successfully during MRI scans. The characteristics of this low-frequency voltage probe allow its use with extreme RF transmission power and magnetic field gradient positioning for MR safety test of AIMD during MRI scans.

  9. Model PET Scan Activity

    Science.gov (United States)

    Strunk, Amber; Gazdovich, Jennifer; Redouté, Oriane; Reverte, Juan Manuel; Shelley, Samantha; Todorova, Vesela

    2018-05-01

    This paper provides a brief introduction to antimatter and how it, along with other modern physics topics, is utilized in positron emission tomography (PET) scans. It further describes a hands-on activity for students to help them gain an understanding of how PET scans assist in detecting cancer. Modern physics topics provide an exciting way to introduce students to current applications of physics.

  10. Investigation of CT scan frequency in children based on RIS in a hospital

    International Nuclear Information System (INIS)

    Sun Yinping; Chen Junbo; Xiao Guobing; Sun Quanfu; Niu Haowei; Fu Yinghua

    2014-01-01

    Objective: To ascertain the frequency distribution of CT examinations in children. Method: A wide range of information was collected through the radiology information system (RIS), including ID, sex, birth date, examination time, the examined part of body and other relevant ones related to children who underwent CT examinations between Jan 1, 2012 and Dec 31, 2012. The SAS software was used for data processing and statistical analysis. Results: A total of 1 542 children underwent 1 670 examinations, of which 67% were male. Head CT examination was the most frequent,accounting for 71.9% of all CT examinations, and followed by the abdomen/pelvis examinations. The number of examinations of children undergoing the repetitive examination accounted for 6.4%; 51.7% of the examinations was for trauma. The positive rate of CT examination was 51%, dependent upon the age and examined body parts to some extent. The younger patients had lower positive rate, and the positive rate of head CT examination was lower than those in other parts. Conclusions: To reduce the possible cancer risk to be induced by the ionizing radiation from CT, justification of CT examination should be considered for children. (authors)

  11. Transverse scan-field imaging apparatus

    International Nuclear Information System (INIS)

    Lyons, F.T.

    1978-01-01

    A description is given of an array of opposed pairs of radiation detectors which could be used in tomography or scintiscanning. The opposed detectors scan in opposite tangential directions in a pre-programmed fashion. The associated control system receives the detector outputs into a buffer store and also provides an address for each element of information detected. The addresses are such that information from one buffer store is read into the RAM of a central processing unit in the opposite direction to that from the store associated with the opposite detector, thus effectively reversing the scan direction of one detector of each pair. Also described are the detectors themselves with focussed collimators, the scan drive mechanism, and the method of calculating radioactive emission intensity at discrete points throughout the scan-field. (author)

  12. Scanning Frequncy Comb Microscopy; a New Tool with Sub-Nm Resolution

    Science.gov (United States)

    Hagmann, Mark; Yarotski, Dmitry

    2016-03-01

    The quasi-periodic excitation of a tunneling junction by a mode-locked ultrafast laser generates a regular sequence of femtosecond pulses of electrons at the pulse repetition rate fR of the laser to be superimposed on the dc tunneling current. In the frequency domain this is equivalent to a microwave frequency comb (MFC) of harmonics at integer multiples of fR. Using a metal tip and sample in a scanning tunneling microscope and a mode-locked Ti:Sapphire laser with a fR of 74.254 MHz, the 200th harmonic at 14.85 GHz has a signal-to-noise ratio of 20 dB, and a linewidth art for narrow-linewidth in a microwave source. The decay in the amplitude of the harmonics with increasing frequency corresponds to a time constant of 320 ps which is attributed to 6.4 pF of shunting capacitance near the junction and the 50 Ω load of the spectrum analyzer. Spreading resistance in semiconductor samples causes the measured attenuation to be sensitive to the local concentration of the carriers. The laser photon energy must be less than the bandgap energy to prevent the creation of electron-hole pairs which would cause surge currents that interfere with the measurements. 2880 S. Main Street #214, Salt Lake City, Utah 84115, USA.

  13. 4D computed tomography scans for conformal thoracic treatment planning: is a single scan sufficient to capture thoracic tumor motion?

    Science.gov (United States)

    Tseng, Yolanda D.; Wootton, Landon; Nyflot, Matthew; Apisarnthanarax, Smith; Rengan, Ramesh; Bloch, Charles; Sandison, George; St. James, Sara

    2018-01-01

    Four dimensional computed tomography (4DCT) scans are routinely used in radiation therapy to determine the internal treatment volume for targets that are moving (e.g. lung tumors). The use of these studies has allowed clinicians to create target volumes based upon the motion of the tumor during the imaging study. The purpose of this work is to determine if a target volume based on a single 4DCT scan at simulation is sufficient to capture thoracic motion. Phantom studies were performed to determine expected differences between volumes contoured on 4DCT scans and those on the evaluation CT scans (slow scans). Evaluation CT scans acquired during treatment of 11 patients were compared to the 4DCT scans used for treatment planning. The images were assessed to determine if the target remained within the target volume determined during the first 4DCT scan. A total of 55 slow scans were compared to the 11 planning 4DCT scans. Small differences were observed in phantom between the 4DCT volumes and the slow scan volumes, with a maximum of 2.9%, that can be attributed to minor differences in contouring and the ability of the 4DCT scan to adequately capture motion at the apex and base of the motion trajectory. Larger differences were observed in the patients studied, up to a maximum volume difference of 33.4%. These results demonstrate that a single 4DCT scan is not adequate to capture all thoracic motion throughout treatment.

  14. Reducing radiation dose in liver enhanced CT scan by setting mAs according to plain scan noise

    International Nuclear Information System (INIS)

    Yang Shangwen; He Jian; Yang Xianfeng; Zhou Kefeng; Xin Xiaoyan; Hu Anning; Zhu Bin

    2013-01-01

    Objective: To investigate the feasibility of setting mAs in liver enhanced CT scan according to plain scan noise with fixed mA CT scanner, in order to reduce the radiation dose. Methods: One hundred continuous patients underwent liver enhanced CT scan (group A) prospectively. Two hundred and fifty mAs was used in plain and enhanced CT scans. Noises of plain and venous phase CT images were measured, and the image quality was evaluated. The equation between mAs of enhanced scan and noise of plain scan image was derived. Another 100 continuous patients underwent liver enhanced CT scan (group B). Enhanced scan mAs was calculated from noise on plain scan by using the equation above. Noises on venous phase images were measured and the image quality was measured. Based on body mass index (BMI), patients in groups A and B were divided into three subgroups respectively: BMI < 18.5 kg/m 2 , 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 and BMI ≥ 25.0 kg/m 2 . Image quality score was compared with nonparametric rank sum test, CT dose index (CTDI) and effective dose (ED) were measured and compared between each subgroup with 2 independent samples t or t' test. Results: The equation between enhanced scan mAs (mAsX) and plain scan noise (SDp) was as follows: mAsX = mAs1 × [(0.989 × SDp + 1.06) /SDx] 2 , mAs1 = 250 mAs, SDx = 13. In patients with BMI < 18.5 kg/m 2 , ED of group A [(6.86 ± 0.38) mSv, n = 12] was significantly higher than group B [(2.66 ± 0.46) mSv, n = 10)] (t = 18.52, P < 0.01). In patients with 18.5 kg/m 2 ≤ BMI < 25.0 kg/m 2 , ED of group A [(7.08 ± 0.91) mSv, n = 66] was significantly higher than group B [(4.50 ± 1.41) mSv, n = 73] (t' = 10.57, P < 0.01). In patients with BMI ≥ 25.0 kg/m 2 , there was no significant difference between EDs of group A (7.54 ± 0.62 mSv, n = 22) and group B [(8.19 ± 3.16) mSv, n = 17] (t' = 0.89, P = 0.39). Image quality of 5 patients in group A and none in group B did not meet the diagnostic requirement

  15. Hepatobiliary scan in neonatal Jaundice

    International Nuclear Information System (INIS)

    Nahar, Nurun; Hasan, Mizanul; Karim, M.A.

    2002-01-01

    Jaundice is more or less common in newborn babies. Through physiological jaundice is most common cause of neonatal jaundice, possibility of obstructive jaundice especially biliary atresia should be kept in mind. Early diagnosis of biliary atresia followed by surgical treatment can save baby's life. Otherwise death is inevitable due to liver failure. Hepatobiliary scan is the imaging study of choice in neonatal jaundice especially when there is persistent conjugated hyperbilirubinaemia. Total 27 newborn babies of suspected biliary atresia, aged 14 days to 4 months were referred to Institute of Nuclear Medicine for Hepatobiliary scan. All of them had high serum bilirubin ranged from 6.0 mg/dl with an average of 9.35 ng/dl serum bilirubin level. Ultrasonography of hepatobiliary system was performed in 14 cases showing normal sized liver in 4 cases and hepatomegaly in 10 cases. Hepatobiliary scan was done with 99m Tc-Mebrofenin (Br IDA) after preparing the baby with phenobarbitone for 3-5 days. 20 (67%) cases were scan positive suggesting biliary atresia (BA) and 7(27%) cases were scan negative. In BA there will be increased hepatic uptake of the radionuclide without any significant excretion even in 24 hours delayed images. Presence of radiotracer in the bowel exclude the diagnosis of BA. Early diagnosis of biliary atresia is very important because in this condition surgery should be performed early (within 60 days of life). Studies suggest that hepatobiliary scan after hepatic stimulation with phenobarbitone for a period of 3-5 days is highly accurate for differentiating biliary atresia from other causes of neonatal jaundice. It is very important to perform hepatobiliary scan in a case of neonatal jaundice to exclude biliary atresia for the sake of baby's life.(author)

  16. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  17. Security scanning of Web sites at CERN

    CERN Multimedia

    IT Department

    2010-01-01

    As of early 2010, the CERN Computer Security Team will start regular scanning of all Web sites and Web applications at CERN, visible on the Internet, or on the General Purpose Network (office network). The goal of this scanning is to improve the quality of CERN Web sites. All deficits found will be reported by e-mail to the relevant Web site owners, and must be fixed in a timely manner. Web site owners may also request one-off scans of their Web site or Web application, by sending an e-mail to Computer.Security@cern.ch. These Web scans are designed to limit the impact on the scanned Web sites. Nevertheless, in very rare cases scans may cause undesired side-effects, e.g. generate a large number of log entries, or cause particularly badly designed or less robust Web applications to crash. If a Web site is affected by these security scans, it will also be susceptible to any more aggressive scan that can be performed any time by a malicious attacker. Such Web applications should be fixed, and also additionally...

  18. Transverse section radionuclide scanning system

    International Nuclear Information System (INIS)

    Kuhl, D.E.; Edwards, R.Q.

    1976-01-01

    This invention provides a transverse section radionuclide scanning system for high-sensitivity quantification of brain radioactivity in cross-section picture format in order to permit accurate assessment of regional brain function localized in three dimensions. High sensitivity crucially depends on overcoming the heretofore known raster type scanning, which requires back and forth detector movement involving dead-time or partial enclosure of the scan field. Accordingly, this invention provides a detector array having no back and forth movement by interlaced detectors that enclose the scan field and rotate as an integral unit around one axis of rotation in a slip ring that continuously transmits the detector data by means of laser emitting diodes, with the advantages that increased amounts of data can be continuously collected, processed and displayed with increased sensitivity according to a suitable computer program. 5 claims, 11 figures

  19. Radionuclide bone scanning of medullary chondrosarcoma

    International Nuclear Information System (INIS)

    Hudson, T.M.; Chew, F.S.; Manaster, B.J.

    1982-01-01

    Technetium-99m methylene diphosphonate bone scans of 18 medullary chondrosarcomas of bone were correlated with pathologic macrosections of the resected tumors. There was increased scan intake by all 18 tumors, and the uptake in 15 scans corresponded accurately to the anatomic extent of the tumors. Only three scans displayed increased uptake beyond the true tumor margins; thus, the ''extended pattern of uptake'' beyond the true tumor extent is much less common in medullary chondrosarcomas than in many other primary bone tumors. Therefore, increased uptake beyond the apparent radiographic margin of the tumor suggests possible occult tumor spread. Pathologically, there was intense reactive new bone formation and hyperemia around the periphery of all 18 tumors, and there were foci of enchondral ossification, hyperemia, or calcification within the tumor itself in nearly every tumor. Three scans displayed less uptake in the center of the tumors than around their peripheries. One of these tumors was necrotic in the center, but the other two were pathologically no different from tumors that displayed homogenous uptake on the scan

  20. Radionuclide bone scanning of medullary chondrosarcoma

    International Nuclear Information System (INIS)

    Hudson, T.M.; Chew, F.S.; Manaster, B.J.

    1982-01-01

    /sup 99m/Tc methylene diphosphonate bone scans of 18 medullary chondrosarcomas of bone were correlated with pathologic macrosections of the resected tumors. There was increased scan uptake by all 18 tumors, and the uptake in 15 scans corresponded accurately to the anatomic extent of the tumors. Only three scans displayed increased uptake beyond the true tumor margins; thus, the extended pattern of uptake beyond the true tumor extent is much less common in medullary chondrosarcomas than in many other primary bone tumors. Therefore, increased uptake beyond the apparent radiographic margin of the tumor suggests possible occult tumor spread. Pathologically, there was intense reactive new bone formation and hyperemia around the periphery of all 18 tumors, and there were foci of enchondral ossification, hyperemia, or calcification within the tumor itself in nearly every tumor. Three scans displayed less uptake in the center of the tumors than around their peripheries. One of these tumors was necrotic in the center, but the other two were pathologically no different from tumors that displayed homogeneous uptake on the scan

  1. Scanning ARM Cloud Radars Part II. Data Quality Control and Processing

    Energy Technology Data Exchange (ETDEWEB)

    Kollias, Pavlos [McGill Univ., Montreal, QC (Canada); Jo, Ieng [McGill Univ., Montreal, QC (Canada); Borque, Paloma [McGill Univ., Montreal, QC (Canada); Tatarevic, Aleksandra [McGill Univ., Montreal, QC (Canada); Lamer, Katia [McGill Univ., Montreal, QC (Canada); Bharadwaj, Nitin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Widener, Kevin B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnson, Karen [Brookhaven National Lab. (BNL), Upton, NY (United States); Clothiaux, Eugene E. [Pennsylvania State Univ., State College, PA (United States)

    2013-10-04

    The Scanning ARM Cloud Radars (SACR’s) are the primary instruments for documenting the four-dimensional structure and evolution of clouds within a 20-30 km radius from the ARM fixed and mobile sites. Here, the post-processing of the calibrated SACR measurements is discussed. First, a feature mask algorithm that objectively determines the presence of significant radar returns is described. The feature mask algorithm is based on the statistical properties of radar receiver noise. It accounts for atmospheric emission and is applicable even for SACR profiles with few or no signal-free range gates. Using the nearest-in-time atmospheric sounding, the SACR radar reflectivities are corrected for gaseous attenuation (water vapor and oxygen) using a line-by-line absorption model. Despite having a high pulse repetition frequency, the SACR has a narrow Nyquist velocity limit and thus Doppler velocity folding is commonly observed. An unfolding algorithm that makes use of a first guess for the true Doppler velocity using horizontal wind measurements from the nearest sounding is described. The retrieval of the horizontal wind profile from the Hemispherical Sky – Range Height Indicator SACR scan observations and/or nearest sounding is described. The retrieved horizontal wind profile can be used to adaptively configure SACR scan strategies that depend on wind direction. Several remaining challenges are discussed, including the removal of insect and second-trip echoes. The described algorithms significantly enhance SACR data quality and constitute an important step towards the utilization of SACR measurements for cloud research.

  2. Signature of magnetic-dependent gapless odd frequency states at superconductor / ferromagnet interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Jason [Department of Materials Science, 27 Charles Babbage Road, Cambridge, CB30FS (United Kingdom)

    2015-07-01

    The theory of superconductivity developed by Bardeen, Cooper, and Schrieffer (BCS) explains the stabilisation of electron pairs into a spin-singlet, even frequency, state by the formation of an energy gap below which the density of states (DoS) is zero. At a superconductor interface with an inhomogeneous ferromagnet, a gapless odd frequency superconducting state is predicted in which the Cooper pairs are in a spin-triplet state. Although indirect evidence for such a state has been obtained, the gap structure and pairing symmetry have not so far been determined. In this talk I will present scanning tunnelling spectroscopy of Nb superconducting films proximity coupled to epitaxial Ho. These measurements reveal pronounced changes to the Nb sub-gap superconducting DoS on driving the Ho through a metamagnetic transition from a helical antiferromagnetic to a homogeneous ferromagnetic state for which a BCS-like gap is recovered. The results verify odd frequency spin-triplet superconductivity at superconductor / inhomogeneous magnet interfaces.

  3. The yule approximation for the site frequency spectrum after a selective sweep.

    Directory of Open Access Journals (Sweden)

    Sebastian Bossert

    Full Text Available In the area of evolutionary theory, a key question is which portions of the genome of a species are targets of natural selection. Genetic hitchhiking is a theoretical concept that has helped to identify various such targets in natural populations. In the presence of recombination, a severe reduction in sequence diversity is expected around a strongly beneficial allele. The site frequency spectrum is an important tool in genome scans for selection and is composed of the numbers S(1,...,S(n-1, where S(k is the number of single nucleotide polymorphisms (SNPs present in k from n individuals. Previous work has shown that both the number of low- and high-frequency variants are elevated relative to neutral evolution when a strongly beneficial allele fixes. Here, we follow a recent investigation of genetic hitchhiking using a marked Yule process to obtain an analytical prediction of the site frequency spectrum in a panmictic population at the time of fixation of a highly beneficial mutation. We combine standard results from the neutral case with the effects of a selective sweep. As simulations show, the resulting formula produces predictions that are more accurate than previous approaches for the whole frequency spectrum. In particular, the formula correctly predicts the elevation of low- and high-frequency variants and is significantly more accurate than previously derived formulas for intermediate frequency variants.

  4. Anthropometric data collection of Portuguese children using 3D body scanning: considerations about the scanning booth

    Science.gov (United States)

    de Campos, R.; Carvalho, M. A.; Lopes, H. P.; Xu, B.

    2017-10-01

    This paper presents some considerations regarding the scanning booth used in an anthropometric study done with a 3D body scanning technology. The data collected is part of a Ph.D. study conducted in Textile Engineering at University of Minho in Portugal, which aims to develop clothing for overweight and obese Portuguese children aged 2-11 years, of both genders. The challenges faced during data collection are described, and modifications of the scanning booth are proposed. It is possible to conclude that the importance of the scanning booth is key to an efficient anthropometric data collection, including the growth of this technology in the garment industry, Universities Research Institutes involved with anthropometric studies.

  5. A scanning tunneling microscope with a scanning range from hundreds of micrometers down to nanometer resolution.

    Science.gov (United States)

    Kalkan, Fatih; Zaum, Christopher; Morgenstern, Karina

    2012-10-01

    A beetle type stage and a flexure scanning stage are combined to form a two stages scanning tunneling microscope (STM). It operates at room temperature in ultrahigh vacuum and is capable of scanning areas up to 300 μm × 450 μm down to resolution on the nanometer scale. This multi-scale STM has been designed and constructed in order to investigate prestructured metallic or semiconducting micro- and nano-structures in real space from atomic-sized structures up to the large-scale environment. The principle of the instrument is demonstrated on two different systems. Gallium nitride based micropillars demonstrate scan areas up to hundreds of micrometers; a Au(111) surface demonstrates nanometer resolution.

  6. Measuring internal friction at sonic and ultrasonic frequencies in high temperature superconductors

    International Nuclear Information System (INIS)

    Anderson, A.R.; Russell, G.J.

    1996-01-01

    Internal friction measurements provide a sensitive means for probing some structural properties of materials. Defect relaxation processes and phase changes are frequently reflected in internal friction measurements as a function of temperature. Relaxation processes associated with oxygen content have been observed in YBCO and BSCCO (2212). By measuring the internal friction at different frequencies activation energies associated with relaxation processes can be determined. Structural changes are temperature dependent and independent of frequency. The composite bar technique developed employs a piezoelectric quartz bar (with lengths of 2 cm or 3 cm and resonant frequencies of approximately 85 kHz or 120 kHz) with a resonant bar of HTSC attached to one end. The quartz bar is suspended at its nodal points and the system excited electrically using a regenerative feedback system. The composite bar method can also be used at low kilohertz frequencies by attaching the HTSC specimen used in the previous technique to the end of a much longer (e g 30 cm) fused silica rod which has very low damping. The resulting composite bar can be excited electrostatically or electromagnetically at frequencies below 10 kHz. The internal friction can be measured by scanning through the resonant frequency and measuring the bandwidth or by observing the decay of free oscillation in the bar. The advantage of using the two composite bar techniques is that the measurements can be made on the same specimen at different frequencies

  7. A numerical algorithm to evaluate the transient response for a synchronous scanning streak camera using a time-domain Baum–Liu–Tesche equation

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Xi' an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); He, Jiai [School of Computer and Communication, Lanzhou University of Technology, Lanzhou, Gansu 730050 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China)

    2016-10-01

    The transient response is of great influence on the electromagnetic compatibility of synchronous scanning streak cameras (SSSCs). In this paper we propose a numerical method to evaluate the transient response of the scanning deflection plate (SDP). First, we created a simplified circuit model for the SDP used in an SSSC, and then derived the Baum–Liu–Tesche (BLT) equation in the frequency domain. From the frequency-domain BLT equation, its transient counterpart was derived. These parameters, together with the transient-BLT equation, were used to compute the transient load voltage and load current, and then a novel numerical method to fulfill the continuity equation was used. Several numerical simulations were conducted to verify this proposed method. The computed results were then compared with transient responses obtained by a frequency-domain/fast Fourier transform (FFT) method, and the accordance was excellent for highly conducting cables. The benefit of deriving the BLT equation in the time domain is that it may be used with slight modifications to calculate the transient response and the error can be controlled by a computer program. The result showed that the transient voltage was up to 1000 V and the transient current was approximately 10 A, so some protective measures should be taken to improve the electromagnetic compatibility.

  8. A numerical algorithm to evaluate the transient response for a synchronous scanning streak camera using a time-domain Baum–Liu–Tesche equation

    International Nuclear Information System (INIS)

    Pei, Chengquan; Tian, Jinshou; Wu, Shengli; He, Jiai; Liu, Zhen

    2016-01-01

    The transient response is of great influence on the electromagnetic compatibility of synchronous scanning streak cameras (SSSCs). In this paper we propose a numerical method to evaluate the transient response of the scanning deflection plate (SDP). First, we created a simplified circuit model for the SDP used in an SSSC, and then derived the Baum–Liu–Tesche (BLT) equation in the frequency domain. From the frequency-domain BLT equation, its transient counterpart was derived. These parameters, together with the transient-BLT equation, were used to compute the transient load voltage and load current, and then a novel numerical method to fulfill the continuity equation was used. Several numerical simulations were conducted to verify this proposed method. The computed results were then compared with transient responses obtained by a frequency-domain/fast Fourier transform (FFT) method, and the accordance was excellent for highly conducting cables. The benefit of deriving the BLT equation in the time domain is that it may be used with slight modifications to calculate the transient response and the error can be controlled by a computer program. The result showed that the transient voltage was up to 1000 V and the transient current was approximately 10 A, so some protective measures should be taken to improve the electromagnetic compatibility.

  9. Measurement techniques for radio frequency nanoelectronics

    CERN Document Server

    Wallis, T Mitch

    2017-01-01

    Connect basic theory with real-world applications with this practical, cross-disciplinary guide to radio frequency measurement of nanoscale devices and materials.• Learn the techniques needed for characterizing the performance of devices and their constituent building blocks, including semiconducting nanowires, graphene, and other two dimensional materials such as transition metal dichalcogenides• Gain practical insights into instrumentation, including on-wafer measurement platforms and scanning microwave microscopy• Discover how measurement techniques can be applied to solve real-world problems, in areas such as passive and active nanoelectronic devices, semiconductor dopant profiling, subsurface nanoscale tomography, nanoscale magnetic device engineering, and broadband, spatially localized measurements of biological materialsFeaturing numerous practical examples, and written in a concise yet rigorous style, this is the ideal resource for researchers, practicing engineers, and graduate students new to ...

  10. Medical Radioisotope Scanning, Vol. II. Proceedings of the Symposium on Medical Radioisotope Scanning

    International Nuclear Information System (INIS)

    1964-01-01

    Medical applications of radioisotopes continue to grow in number and importance and medical centres in almost all countries of the world are now using radioactive materials both in the diagnosis and treatment of disease. An increasing proportion of these applications involves studies of the spatial distribution of radioactive material within the human body, for which purpose highly specialized scanning methods have been elaborated. By these methods it is possible to study the position, size and functional state of different organs, to detect tumours, cysts and other abnormalities and to obtain much useful information about regions of the body that are otherwise inaccessible, except by surgery. Progress in scanning methods in recent years has been very rapid and there have been many important advances in instrumentation and technique. The development of new forms of the gamma camera and of colour-scanning techniques are but two examples of recent improvements. The production of new radioisotopes and new labelled compounds has further extended the scope of these methods. To survey these new advances the International Atomic Energy Agency held a Symposium on Medical Radioisotope Scanning in Athens from 20-24 April 1964. The scientific programme of the meeting covered all aspects of scanning methods including theoretical principles, instrumentation, techniques and clinical applications. The World Health Organization assisted in the selection of papers by providing a consultant to the selection committee. The meeting followed the earlier IAEA/WHO Seminar on Medical Radioisotope Scanning in Vienna in 1959, which was attended by 36 participants and at which 14 papers were presented. Some idea of the growth of interest in the subject may be gained from the fact that the Symposium was attended by 160 participants from 26 countries and 4 international organizations, and that 58 papers were presented. The published proceedings, comprising two volumes, contain all the

  11. Gallium-67 citrate scan in extrapulmonary tuberculosis

    International Nuclear Information System (INIS)

    Lin Wanyu

    1999-01-01

    Aim: Whole-body gallium scan was performed to evaluate the usefulness of gallium scan for detecting extrapulmonary tuberculosis (TB) lesions. Methods: Thirty-seven patients with extrapulmonary TB were included in this study. Four patients were found to have two lesions. Totally, 41 lesions were identified, including 19 TB arthritis, 8 spinal TB, 5 TB meningitis, 3 TB lymphadenopathy, 2 TB pericarditis, 1 TB peritonitis, 1 intestinal TB, 1 skin TB and 1 renal TB. Results: Of the 41 extrapulmonary TB lesions, gallium scan detected 32 lesions with a sensitivity of 78%. All the patients with TB meningitis showed negative gallium scan. When the five cases of TB meningitis were excluded, the detection sensitivity of gallium scan increased to 88.9% (32/36). Conclusion: Our data revealed that gallium scan is a convenient and useful method for evaluating extrapulmonary TB lesions other than TB-meningitis. We suggest that gallium scan be included in the clinical routine for patients with suspected extrapulmonary TB. (orig.) [de

  12. Scanning table

    CERN Multimedia

    1960-01-01

    Before the invention of wire chambers, particles tracks were analysed on scanning tables like this one. Today, the process is electronic and much faster. Bubble chamber film - currently available - (links can be found below) was used for this analysis of the particle tracks.

  13. Time-resolved scanning tunnelling microscopy

    NARCIS (Netherlands)

    van Houselt, Arie; Zandvliet, Henricus J.W.

    2010-01-01

    Scanning tunneling microscopy has revolutionized our ability to image, study, and manipulate solid surfaces on the size scale of atoms. One important limitation of the scanning tunneling microscope (STM) is, however, its poor time resolution. Recording a standard image with a STM typically takes

  14. COMPUTED TOMOGRAPHY SCAN FINDINGS OF PATIENTS PRESENTING WITH HEADACHE AT TRIPURA MEDICAL COLLEGE AND DR. B.R. AMBEDKAR MEMORIAL TEACHING HOSPITAL, HAPANIA, AGARTALA, TRIPURA- A CROSS-SECTIONAL STUDY

    Directory of Open Access Journals (Sweden)

    Biplab Debbarma

    2017-10-01

    Full Text Available BACKGROUND Headache is one of the causes of discomfort to a human being and can be classified as primary or secondary headache. CT scan has proved to be useful when the neurological physical examination is abnormal. The aim of the study is to1. Determine the causes of headache of patients presenting with nontraumatic headache by CT scan at Tripura Medical College and Dr. B.R. Ambedkar Memorial Teaching Hospital, Hapania, Agartala, West Tripura. 2. Correlate the clinical diagnosis and the CT scan findings of patients with nontraumatic headache. MATERIALS AND METHODS A total of 157 patients presented with nontraumatic headache underwent CT scan examination in the Radiodiagnosis Department of Tripura Medical College and Dr. B.R. Ambedkar Memorial Teaching Hospital, Hapania, Agartala, West Tripura and scans were viewed for the presence of any secondary cause of headache and findings were expressed as frequency and percentage. Statistical Analysis- The data were entered in spreadsheet and analysed using SPSS 21 statistical software. Results were expressed as frequency and percentage. RESULTS In our study, female patients (50.96% were slightly more than the male (49.04% patients and majority of the patients were in the age group of >20 to ≤40 years (54.14% followed by >40 to ≤60 years (25.47%.Primary headache (73.89% was found to be more common than secondary headache (26.11%. Sinusitis (73.17% was the commonest cause of secondary headache. Prevalence of positive CT scans of patients presenting with headache was 26.11%. Most of the clinical diagnosis did not correlate (61.78% with the CT scan finding. Patients with clinical diagnosis of migraine correlates mostly with the CT scan finding (69.44%, which is one of commonest cause of primary headache where we got negative findings in CT scan followed by sinusitis (38.77%, CVA/ICH (cerebrovascular accident and intracerebral haemorrhage 32.25% and brain SOL (25%. CONCLUSION CT scan has a role in

  15. Technique for the focal-length measurement of positive lenses using Fizeau interferometry

    International Nuclear Information System (INIS)

    Pavan Kumar, Yeddanapudi; Chatterjee, Sanjib

    2009-01-01

    We present what we believe is a new technique for the focal-length measurement of positive lenses using Fizeau interferometery. The technique utilizes the Gaussian lens equation. The image distance is measured interferometrically in terms of the radius of curvature of the image-forming wavefront emerging from the lens. The radii of curvature of the image-forming wavefronts corresponding to two different axial object positions of known separation are measured. The focal length of the lens is determined by solving the equations obtained using the Gaussian lens equation for the two object positions. Results obtained for a corrected doublet lens of a nominal focal length of 200.0 mm with a measurement uncertainty of ±2.5% is presented

  16. Interferometer tests for quantum non-locality using Bose-Einstein condensates

    Energy Technology Data Exchange (ETDEWEB)

    Mullin, W J [Department of Physics, University of Massachusetts, Amherst, Massachusetts 01003 (United States); Laloe, F [Laboratoire Kastler Brossel, ENS, UPMC, CNRS, 24 rue Lhomond, 75005 Paris (France)], E-mail: mullin@physics.umass.edu, E-mail: laloe@lkb.ens.fr

    2009-02-01

    In conventional Einstein-Rosen-Podolsky (EPR) experiments that violate local realism, particles are placed in very particular entangled states. We propose here to use two or three spinless Fock-state Bose-Einstein condensates as independent sources in interferometery experiments. While these states do not seem to be entangled, nevertheless we show that interferometers can be constructed that demonstrate a large variety of different violations local reality. We find violations of Bell inequalities, new Greenberger-Horne-Zeilinger (GHZ) contradictions, and Hardy impossibilities. These violations continue to arbitrarily large particle numbers. A necessary condition to observe the quantum effects is that all particles should be observed; if some are missed, the quantum effects disappear.

  17. Status of automated nuclear scanning systems

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Preston, C.C.; McNeece, J.P.; Ruddy, F.H.

    1983-07-01

    Present day minicomputers and microprocessors enable a range of automation, from partial to total, of tasks once thought beyond approach. The status of three computer controlled systems for quantitative track measurements is reviewed. Two systems, the Hanford optical track scanner (HOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third systems, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Current limitations of these systems for quantitative track scanning are presented. Experimental uncertainties attained with these computer controlled systems are described using results obtained from reactor neutron dosimetry

  18. Analysis of classical guitars' vibrational behavior based on scanning laser vibrometer measurements

    Science.gov (United States)

    Czajkowska, Marzena

    2012-06-01

    One of the main goals in musical acoustics research is to link measurable, physical properties of a musical instrument with subjective assessments of its tone quality. The aim of the research discussed in this paper was to observe the structural vibrations of different class classical guitars in relation to their quality. This work focuses on mid-low-and low-class classical (nylon-stringed) guitars. The main source of guitar body vibrations come from top and back plate vibrations therefore these were the objects of structural mode measurements and analysis. Sixteen classical guitars have been investigated, nine with cedar and seven with spruce top plate. Structural modes of top and back plates have been measured with the aid of a scanning laser vibrometer and the instruments were excited with a chirp signal transferred by bone vibrator. The issues related to excitor selection have been discussed. Correlation and descriptive statistics of top and back plates measurement results have been investigated in relation to guitar quality. The frequency range of 300 Hz to 5 kHz as well as selected narrowed frequency bands have been analyzed for cedar and spruce guitars. Furthermore, the influence of top plate wood type on vibration characteristics have been observed on three pairs of guitars. The instruments were of the same model but different top plate material. Determination and visualization of both guitar plates' modal patterns in relation to frequency are a significant attainment of the research. Scanning laser vibrometer measurements allow particular mode observation and therefore mode identification, as opposed to sound pressure response measurements. When correlating vibration characteristics of top and back plates it appears that Pearson productmoment correlation coefficient is not a parameter that associates with guitar quality. However, for best instruments with cedar top, top-back correlation coefficient has relatively greater value in 1-2 kHz band and lower in

  19. Clinical significance of bone scintigraphy and computerized tomography (CT scan) in the evaluation of renal osteodystrophy in haemodialysed and non-haemodialysed patients

    International Nuclear Information System (INIS)

    Yatsuboshi, Motohiko

    1978-01-01

    For the evaluation of renal osteodystophy in both haemodialysed and non-haemodialysed patients, bone scintigraphy and computerized tomography (CT) scan were performed. Twenty-six patients with chronic renal failure were objectives of the study. For the control study of CT scan, patients with brain tumor without renal disease were selected. Bone scan was performed approximately 3 hours after sup(99m) Tc-EHDP (ethane-1-hydroxy-1, 1-diphosphonate) administration. The numericals which were printed out from CT scanner were analyzed in the area of frontal bone. The number of positive group was 9 and that of negative was 17. Positive group in non-haemodialysed patients showed lower serum calcium level and creatinine clearance and higher serum levels of inorganic phosphate and BUN compared with those of negative group. Positive scan group showed longer duration of dialysis and higher serum levels of parathyroid hormone and alkaline phosphatase than those of negative group. Frequency of abnormal findings detected by bone scan was higher than that elicited by roentgenographic examination. CT number of positive scan group was lower than that of negative group or control group. CT number in patients with subperiosteal resorption of phalanx and abnormal findings of calvarium was lower than that of patients without such roentgenographic abnormalities. These findings indicate that bone scan is useful in detecting bone changes of secondary hyperparathyroidism in chronic renal failure. CT scan could also help to estimate the decrease of bone density of calvarium in chronic renal failure. (author)

  20. Method and apparatus for scanning a transverse field

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1978-01-01

    A transverse radionuclide scan-field imaging apparatus is described for use in scanning with particular reference to the brain. It comprises a plurality of highly focussed collimators surrounding and being focussed inwardly with respect to the scan-field and means for imparting movement to the collimators. Adjacent collimators can be stepped in radially opposite directions after each tangential scan, so that the focal point of each collimator scans at least one half of the scan-field. Each collimator is associated with a scintillator crystal and photodetector whose output is used to calculate the radioactive emission intensity at a number of points in the scan-field. (author)

  1. Multiple bony lesions other than femoral heads on 99mTc-MDP bone scan in patients with avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung; Chun, Hae Kyung

    1997-01-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%;the location of 79 lesions was other than the femoral head, This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated

  2. Improved CT-detection of acute bowel ischemia using frequency selective non-linear image blending.

    Science.gov (United States)

    Schneeweiss, Sven; Esser, Michael; Thaiss, Wolfgang; Boesmueller, Hans; Ditt, Hendrik; Nikolau, Konstantin; Horger, Marius

    2017-07-01

    Computed tomography (CT) as a fast and reliable diagnostic technique is the imaging modality of choice for acute bowel ischemia. However, diagnostic is often difficult mainly due to low attenuation differences between ischemic and perfused segments. To compare the diagnostic efficacy of a new post-processing tool based on frequency selective non-linear blending with that of conventional linear contrast-enhanced CT (CECT) image blending for the detection of bowel ischemia. Twenty-seven consecutive patients (19 women; mean age = 73.7 years, age range = 50-94 years) with acute bowel ischemia were scanned using multidetector CT (120 kV; 100-200 mAs). Pre-contrast and portal venous scans (65-70 s delay) were acquired. All patients underwent surgery for acute bowel ischemia and intraoperative diagnosis as well as histologic evaluation of explanted bowel segments was considered "gold standard." First, two radiologists read the conventional CECT images in which linear blending was adapted for optimal contrast, and second (three weeks later) the frequency selective non-linear blending (F-NLB) image. Attenuation values were compared, both in the involved and non-involved bowel segments creating ratios between unenhanced and CECT. The mean attenuation difference between ischemic and non-ischemic wall in the portal venous scan was 69.54 HU (reader 2 = 69.01 HU) higher for F-NLB compared with conventional CECT. Also, the attenuation ratio between contrast-enhanced and pre-contrast CT data for the non-ischemic walls showed significantly higher values for the F-NLB image (CECT: reader 1 = 2.11 (reader 2 = 3.36), F-NLB: reader 1 = 4.46 (reader 2 = 4.98)]. Sensitivity in detecting ischemic areas increased significantly for both readers using F-NLB (CECT: reader 1/2 = 53%/65% versus F-NLB: reader 1/2 = 62%/75%). Frequency selective non-linear blending improves detection of bowel ischemia compared with conventional CECT by increasing

  3. A Study for Reappearance According to the Scan Type, the CT Scanning by a Moving Phantom

    International Nuclear Information System (INIS)

    Choi, Jae Hyock; Jeong, Do Hyeong; Choi, Gye Suk; Jang, Yo Jong; Kim, Jae Weon; Lee, Hui Seok

    2007-01-01

    CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Total volume of a marker was 88.2 cm 3 considering movement of superior-inferior. Total volume was 184.3 cm 3 . Total volume according to each CT scan protocol were 135 cm 3 by axial mode, 164.9 cm 3 by helical mode, 181.7 cm 3 by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  4. Difference frequency generation spectroscopy as a vibrational optical activity measurement tool.

    Science.gov (United States)

    Cheon, Sangheon; Cho, Minhaeng

    2009-03-19

    Vibrational optical activity (VOA) of chiral molecules in condensed phases can be studied by using vibrational circular dichroism and Raman optical activity measurement techniques. Recently, IR-vis sum frequency generation has shown to be an alternative VOA measurement method. Such a three-wave-mixing method employing a polarization modulation technique can be a potentially useful VOA measurement tool. Here, a theoretical description of difference frequency generation (DFG) employing circularly polarized visible radiations is presented. Frequency scanning to obtain a VOA-DFG spectrum is achieved by controlling the difference between the two electronically nonresonant incident radiation frequencies. If the two incident beams are linearly polarized and their polarization directions are perpendicular to each other, one can selectively measure the all-electric-dipole-allowed chiral component of the DFG susceptibility. In addition, by using circularly polarized beams and taking the DFG difference intensity signal, which is defined as the difference between left and right circularly polarized DFG signals, additional chiral susceptibility components originating from the electric quadrupole transition can be measured. The DFG as a novel VOA measurement technique for solution samples containing chiral molecules will therefore be a useful coherent spectroscopic tool for determining absolute configuration of chiral molecules in condensed phases.

  5. Scanning the phenomenological MSSM

    CERN Document Server

    Wuerzinger, Jonas

    2017-01-01

    A framework to perform scans in the 19-dimensional phenomenological MSSM is developed and used to re-evaluate the ATLAS experiments' sensitivity to R-parity-conserving supersymmetry with LHC Run 2 data ($\\sqrt{s}=13$ TeV), using results from 14 separate ATLAS searches. We perform a $\\tilde{t}_1$ dedicated scan, only considering models with $m_{\\tilde{t}_1}<1$ TeV, while allowing both a neutralino ($\\tilde{\\chi}_1^0$) and a sneutrino ($\\tilde{\

  6. Characterization of ultrashort laser pulses employing self-phase modulation dispersion-scan technique

    Science.gov (United States)

    Sharba, A. B.; Chekhlov, O.; Wyatt, A. S.; Pattathil, R.; Borghesi, M.; Sarri, G.

    2018-03-01

    We present a new phase characterization technique for ultrashort laser pulses that employs self-phase modulation (SPM) in the dispersion scan approach. The method can be implemented by recording a set of nonlinearly modulated spectra generated with a set of known chirp values. The unknown phase of the pulse is retrieved by linking the recorded spectra to the initial spectrum of the pulse via a phase function guessed by a function minimization iterative algorithm. This technique has many advantages over the dispersion scan techniques that use frequency conversion processes. Mainly, the use of SPM cancels out the phase and group velocity mismatch errors and dramatically widens the spectral acceptance of the nonlinear medium and the range of working wavelength. The robustness of the technique is demonstrated with smooth and complex phase retrievals using numerical examples. The method is shown to be not affected by the spatial distribution of the beam or the presence of nonlinear absorption process. In addition, we present an efficient method for phase representation based on a summation of a set of Gaussian functions. The independence of the functions from each other prevents phase coupling of any kind and facilitates a flexible phase representation.

  7. Diagnostic value of axial CT scan

    International Nuclear Information System (INIS)

    Kiuchi, Sousuke

    1983-01-01

    Axial CT scan was used to investigate the radiological details of the temporal bone of 33 patients with chronic otitis media, secondary cholesteatoma, sensorineural hearing loss, Meniere disease, vertigo, facial spasm, and neoplasma. The axial scans showed anatomic details of the temporal bone, and at the same time clearly demonstrated the extent of the soft-tissue masses in the middle ears, as well as the destructions of the ossicles. Bone changes of the anterior walls of the epitympanum and external auditory meatus were more clearly demonstrated than by coronary CT scan. However, the axial scan had the disadvantages in demonstrating the stapes, crista transversa, and the mastoid portion of the facial canal. (author)

  8. Structural health monitoring in composite materials using frequency response methods

    Science.gov (United States)

    Kessler, Seth S.; Spearing, S. Mark; Atalla, Mauro J.; Cesnik, Carlos E. S.; Soutis, Constantinos

    2001-08-01

    Cost effective and reliable damage detection is critical for the utilization of composite materials in structural applications. Non-destructive evaluation techniques (e.g. ultrasound, radiography, infra-red imaging) are available for use during standard repair and maintenance cycles, however by comparison to the techniques used for metals these are relatively expensive and time consuming. This paper presents part of an experimental and analytical survey of candidate methods for the detection of damage in composite materials. The experimental results are presented for the application of modal analysis techniques applied to rectangular laminated graphite/epoxy specimens containing representative damage modes, including delamination, transverse ply cracks and through-holes. Changes in natural frequencies and modes were then found using a scanning laser vibrometer, and 2-D finite element models were created for comparison with the experimental results. The models accurately predicted the response of the specimems at low frequencies, but the local excitation and coalescence of higher frequency modes make mode-dependent damage detection difficult and most likely impractical for structural applications. The frequency response method was found to be reliable for detecting even small amounts of damage in a simple composite structure, however the potentially important information about damage type, size, location and orientation were lost using this method since several combinations of these variables can yield identical response signatures.

  9. The Enhancement of 3D Scans Depth Resolution Obtained by Confocal Scanning of Porous Materials

    Science.gov (United States)

    Martisek, Dalibor; Prochazkova, Jana

    2017-12-01

    The 3D reconstruction of simple structured materials using a confocal microscope is widely used in many different areas including civil engineering. Nonetheless, scans of porous materials such as concrete or cement paste are highly problematic. The well-known problem of these scans is low depth resolution in comparison to the horizontal and vertical resolution. The degradation of the image depth resolution is caused by systematic errors and especially by different random events. Our method is focused on the elimination of such random events, mainly the additive noise. We use an averaging method based on the Lindeberg-Lévy theorem that improves the final depth resolution to a level comparable with horizontal and vertical resolution. Moreover, using the least square method, we also precisely determine the limit value of a depth resolution. Therefore, we can continuously evaluate the difference between current resolution and the optimal one. This substantially simplifies the scanning process because the operator can easily determine the required number of scans.

  10. The Enhancement of 3D Scans Depth Resolution Obtained by Confocal Scanning of Porous Materials

    Directory of Open Access Journals (Sweden)

    Martisek Dalibor

    2017-12-01

    Full Text Available The 3D reconstruction of simple structured materials using a confocal microscope is widely used in many different areas including civil engineering. Nonetheless, scans of porous materials such as concrete or cement paste are highly problematic. The well-known problem of these scans is low depth resolution in comparison to the horizontal and vertical resolution. The degradation of the image depth resolution is caused by systematic errors and especially by different random events. Our method is focused on the elimination of such random events, mainly the additive noise. We use an averaging method based on the Lindeberg-Lévy theorem that improves the final depth resolution to a level comparable with horizontal and vertical resolution. Moreover, using the least square method, we also precisely determine the limit value of a depth resolution. Therefore, we can continuously evaluate the difference between current resolution and the optimal one. This substantially simplifies the scanning process because the operator can easily determine the required number of scans.

  11. Scanning by use of TV

    International Nuclear Information System (INIS)

    Drevermann, H.

    1981-01-01

    The use of TV read out for scanning and measuring holographic pictures seems to give less problems than the use of optical projection as is usual for conventional bubble chamber photos. Whereas the measuring of conventional bubble chamber pictures seems to give no problems, it is not clear whether scanning by use of TV is possible. Therefore scanning pictures from experiment NA16 (taken in LEBC) with TV only was tried using the TV system of ERASME, where the CRT system is used as a camera. It should be mentioned that this system, being a flying spot device, cannot be adapted for holography. (author)

  12. Scanning vector Hall probe microscopy

    International Nuclear Information System (INIS)

    Cambel, V.; Gregusova, D.; Fedor, J.; Kudela, R.; Bending, S.J.

    2004-01-01

    We have developed a scanning vector Hall probe microscope for mapping magnetic field vector over magnetic samples. The microscope is based on a micromachined Hall sensor and the cryostat with scanning system. The vector Hall sensor active area is ∼5x5 μm 2 . It is realized by patterning three Hall probes on the tilted faces of GaAs pyramids. Data from these 'tilted' Hall probes are used to reconstruct the full magnetic field vector. The scanning area of the microscope is 5x5 mm 2 , space resolution 2.5 μm, field resolution ∼1 μT Hz -1/2 at temperatures 10-300 K

  13. Tomography system having axial scanning

    International Nuclear Information System (INIS)

    1976-01-01

    An improved method and apparatus has been invented for the transaxial tomographic scanning of a patient to determine mass distribution internal to the patient. A scanning system is provided having a rotatably mounted X-ray radiation source/detector assembly which orbits and scans the patient in plane of orbit. The source provides a plurality of beams of radiation in the orbital plane. Beams pass through the patient to an array of detectors which are spaced in the plane of orbit and respectively aligned with one of the beams. Radiation intensity data is collected at predetermined orientations of each beam-detector pair as the assembly orbits about the patient

  14. An empirical Bayes method for updating inferences in analysis of quantitative trait loci using information from related genome scans.

    Science.gov (United States)

    Zhang, Kui; Wiener, Howard; Beasley, Mark; George, Varghese; Amos, Christopher I; Allison, David B

    2006-08-01

    Individual genome scans for quantitative trait loci (QTL) mapping often suffer from low statistical power and imprecise estimates of QTL location and effect. This lack of precision yields large confidence intervals for QTL location, which are problematic for subsequent fine mapping and positional cloning. In prioritizing areas for follow-up after an initial genome scan and in evaluating the credibility of apparent linkage signals, investigators typically examine the results of other genome scans of the same phenotype and informally update their beliefs about which linkage signals in their scan most merit confidence and follow-up via a subjective-intuitive integration approach. A method that acknowledges the wisdom of this general paradigm but formally borrows information from other scans to increase confidence in objectivity would be a benefit. We developed an empirical Bayes analytic method to integrate information from multiple genome scans. The linkage statistic obtained from a single genome scan study is updated by incorporating statistics from other genome scans as prior information. This technique does not require that all studies have an identical marker map or a common estimated QTL effect. The updated linkage statistic can then be used for the estimation of QTL location and effect. We evaluate the performance of our method by using extensive simulations based on actual marker spacing and allele frequencies from available data. Results indicate that the empirical Bayes method can account for between-study heterogeneity, estimate the QTL location and effect more precisely, and provide narrower confidence intervals than results from any single individual study. We also compared the empirical Bayes method with a method originally developed for meta-analysis (a closely related but distinct purpose). In the face of marked heterogeneity among studies, the empirical Bayes method outperforms the comparator.

  15. Serial cranial computed-tomography scans in children with leukemia given two different forms of central nervous system therapy

    International Nuclear Information System (INIS)

    Ochs, J.J.; Parvey, L.S.; Whitaker, J.N.; Bowman, W.P.; Ch'ien, L.; Campbell, M.; Coburn, T.

    1983-01-01

    Cranial computed tomography (CT) was used to estimate the frequency and permanence of brain abnormalities in 108 consecutive children with acute lymphoblastic leukemia (ALL). Fifty-five patients received cranial irradiation (1,800 rad) with intrathecal methotrexate (RT group) and 53 patients received intravenous and intrathecal methotrexate without irradiation (IVIT group). Continuation treatment included sequential drug pairs for the RT group and periodic IVIT methotrexate for the other group. After 12 to 24 months of serial evaluation, five (9%) of the 55 patients in the RT group have had CT scan abnormalities, compared to 10 (19%) of 52 in the IVIT group (p . 0.171). Fourteen of the 15 patients with CT scan abnormalities had focal or diffuse white-matter hypodensity; these have reverted to normal in most cases, reflecting a dynamic process. While such CT findings are of concern and may be an early indicator of central nervous system toxicity, this remains to be proven. Therapy should not be altered on the basis of abnormal CT scans alone but in the context of the entire clinical situation

  16. Scanning probe microscopy

    International Nuclear Information System (INIS)

    Mainsbridge, B.

    1994-01-01

    In late 1959, Richard Feynman observed that manoeuvring atoms was something that could be done in principle but has not been done, 'because we are too big'. In 1982, the scanning tunnelling microscope (STM) was invented and is now a central tool for the construction of nanoscale devices in what was known as molecular engineering, and now, nanotechnology. The principles of the microscope are outlined and references are made to other scanning devices which have evolved from the original invention. The method of employment of the STM as a machine tool is described and references are made to current speculations on applications of the instrument in nanotechnology. A short bibliography on this topic is included. 27 refs., 7 figs

  17. Scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Mainsbridge, B [Murdoch Univ., WA (Australia). School of Mathematical and Physical Sciences

    1994-12-31

    In late 1959, Richard Feynman observed that manoeuvring atoms was something that could be done in principle but has not been done, `because we are too big`. In 1982, the scanning tunnelling microscope (STM) was invented and is now a central tool for the construction of nanoscale devices in what was known as molecular engineering, and now, nanotechnology. The principles of the microscope are outlined and references are made to other scanning devices which have evolved from the original invention. The method of employment of the STM as a machine tool is described and references are made to current speculations on applications of the instrument in nanotechnology. A short bibliography on this topic is included. 27 refs., 7 figs.

  18. Quantitative sub-surface and non-contact imaging using scanning microwave microscopy

    International Nuclear Information System (INIS)

    Gramse, Georg; Kasper, Manuel; Hinterdorfer, Peter; Brinciotti, Enrico; Rankl, Christian; Kienberger, Ferry; Lucibello, Andrea; Marcelli, Romolo; Patil, Samadhan B.; Giridharagopal, Rajiv

    2015-01-01

    The capability of scanning microwave microscopy for calibrated sub-surface and non-contact capacitance imaging of silicon (Si) samples is quantitatively studied at broadband frequencies ranging from 1 to 20 GHz. Calibrated capacitance images of flat Si test samples with varying dopant density (10 15 –10 19 atoms cm −3 ) and covered with dielectric thin films of SiO 2 (100–400 nm thickness) are measured to demonstrate the sensitivity of scanning microwave microscopy (SMM) for sub-surface imaging. Using standard SMM imaging conditions the dopant areas could still be sensed under a 400 nm thick oxide layer. Non-contact SMM imaging in lift-mode and constant height mode is quantitatively demonstrated on a 50 nm thick SiO 2 test pad. The differences between non-contact and contact mode capacitances are studied with respect to the main parameters influencing the imaging contrast, namely the probe tip diameter and the tip–sample distance. Finite element modelling was used to further analyse the influence of the tip radius and the tip–sample distance on the SMM sensitivity. The understanding of how the two key parameters determine the SMM sensitivity and quantitative capacitances represents an important step towards its routine application for non-contact and sub-surface imaging. (paper)

  19. TU-F-BRF-03: Effect of Radiation Therapy Planning Scan Registration On the Dose in Lung Cancer Patient CT Scans

    International Nuclear Information System (INIS)

    Cunliffe, A; Contee, C; White, B; Justusson, J; Armato, S; Malik, R; Al-Hallaq, H

    2014-01-01

    Purpose: To characterize the effect of deformable registration of serial computed tomography (CT) scans on the radiation dose calculated from a treatment planning scan. Methods: Eighteen patients who received curative doses (≥60Gy, 2Gy/fraction) of photon radiation therapy for lung cancer treatment were retrospectively identified. For each patient, a diagnostic-quality pre-therapy (4–75 days) CT scan and a treatment planning scan with an associated dose map calculated in Pinnacle were collected. To establish baseline correspondence between scan pairs, a researcher manually identified anatomically corresponding landmark point pairs between the two scans. Pre-therapy scans were co-registered with planning scans (and associated dose maps) using the Plastimatch demons and Fraunhofer MEVIS deformable registration algorithms. Landmark points in each pretherapy scan were automatically mapped to the planning scan using the displacement vector field output from both registration algorithms. The absolute difference in planned dose (|ΔD|) between manually and automatically mapped landmark points was calculated. Using regression modeling, |ΔD| was modeled as a function of the distance between manually and automatically matched points (registration error, E), the dose standard deviation (SD-dose) in the eight-pixel neighborhood, and the registration algorithm used. Results: 52–92 landmark point pairs (median: 82) were identified in each patient's scans. Average |ΔD| across patients was 3.66Gy (range: 1.2–7.2Gy). |ΔD| was significantly reduced by 0.53Gy using Plastimatch demons compared with Fraunhofer MEVIS. |ΔD| increased significantly as a function of E (0.39Gy/mm) and SD-dose (2.23Gy/Gy). Conclusion: An average error of <4Gy in radiation dose was introduced when points were mapped between CT scan pairs using deformable registration. Dose differences following registration were significantly increased when the Fraunhofer MEVIS registration algorithm was used

  20. Detection of Arthritis by Joint Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Maxfield, W. S. [Dept, of Radiology, Louisiana State University School of Medicine, New Orleans, LA (United States); Weiss, T. E.; Tutton, R. H.; Hidalgo, J. U. [Ochsner Clinic and Ochsner Foundation Hospital, New Orleans, LA (United States)

    1969-05-15

    Detection and identification of early arthritis is frequently difficult with routine methods. Several tracers, {sup 131}I human serum albumin (25 {mu}Ci/10 lb), {sup 99m}Tc human serum albumin (1-3 mCi), {sup 131}I iodipamide (40 {mu}Ci/10 lb), and {sup 99m}Tc pertechnetate (10 mCi), have been employed for joint scanning to detect synovitis produced by arthritis in joints of the extremities. When administered intravenously, the 25% increase in localization of these tracers in the synovial membrane, if there is active synovitis, can be demonstrated by scintillation scanning. This ability to detect synovitis at an early stage enables the joint scan to show areas of active synovitis not demonstrated on roentgenograms. The scan may objectively confirm or disprove questionable physical findings. From this standpoint the technique has been useful in determining whether joint pain is functional or due to arthritis as a negative localization tends to rule out active synovitis as the cause of the pain. The scan demonstration of a positive localization of the tracer in several joints when only one area is symptomatic is evidence that joint pain is due to systemic disease. The short half-life tracera permit serial studies to follow the course of an arthritis process. Use of {sup 99m}Tc pertechnetate and an Anger camera have made joint scanning a practical technique for clinical use. A review of the accuracy of joint scanning in 130 cases as compared to roentgenograms is presented. (author)

  1. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  2. Scan Statistics

    CERN Document Server

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  3. SCANNING AND TRACKING MONITORING APPARATUS AND METHOD

    DEFF Research Database (Denmark)

    2017-01-01

    Disclosed is a scanning monitoring apparatus for medical imaging, the scanning monitoring apparatus comprising a controller unit and a display, wherein the controller unit during a scanning session is configured to obtain tracking data (102) of a subject in a medical scanner, obtain scanner data ...

  4. Construction of a four tip scanning tunneling microscope/scanning electron microscope combination and conductivity measurements of silicide nanowires; Aufbau einer Vierspitzen-Rastertunnelmikroskop/Rasterelektronenmikroskop-Kombination und Leitfaehigkeitsmessungen an Silizid Nanodraehten

    Energy Technology Data Exchange (ETDEWEB)

    Zubkov, Evgeniy

    2013-09-01

    In this work the combination of a four-tip scanning tunneling microscope with a scanning electron microscope is presented. By means of this apparatus it is possible to perform the conductivity measurements on the in-situ prepared nanostructures in ultra-high vacuum. With the aid of a scanning electron microscope (SEM), it becomes possible to position the tunneling tips of the four-tip scanning tunneling microscope (STM), so that an arrangement for a four-point probe measurement on nanostructures can be obtained. The STM head was built according to the novel coaxial Beetle concept. This concept allows on the one hand, a very compact arrangement of the components of the STM and on the other hand, the new-built STM head has a good mechanical stability, in order to achieve atomic resolution with all four STM units. The atomic resolution of the STM units was confirmed by scanning a Si(111)-7 x 7 surface. The thermal drift during the STM operation, as well as the resonant frequencies of the mechanical structure of the STM head, were determined. The scanning electron microscope allows the precise and safe navigation of the tunneling tips on the sample surface. Multi tip spectroscopy with up to four STM units can be performed synchronously. To demonstrate the capabilities of the new-built apparatus the conductivity measurements were carried out on metallic yttrium silicide nanowires. The nanowires were prepared by the in-situ deposition of yttrium on a heated Si(110) sample surface. Current-voltage curves were recorded on the nanowires and on the wetting layer in-between. The curves indicate an existence of the Schottky barrier between the yttrium silicide nanowires and the silicon bulk. By means of the two-tip measurements with a gate, the insulating property of the Schottky barrier has been confirmed. Using this Schottky barrier, it is possible to limit the current to the nanowire and to prevent it from flowing through the silicon bulk. A four-tip resistance measurement

  5. Osmotic blood-brain barrier modification: clinical documentation by enhanced CT scanning and/or radionuclide brain scanning

    International Nuclear Information System (INIS)

    Neuwelt, E.A.; Specht, H.D.; Howieson, J.; Haines, J.E.; Bennett, M.J.; Hill, S.A.; Frenkel, E.P.

    1983-01-01

    Results of initial clinical trials of brain tumor chemotherapy after osmotic blood-brain barrier disruption are promising. In general, the procedure is well tolerated. The major complication has been seizures. In this report, data are presented which indicate that the etiology of these seizures is related to the use of contrast agent (meglumine iothalamate) to monitor barrier modification. A series of 19 patients underwent a total of 85 barrier modification procedures. Documentation of barrier disruption was monitored by contrast-enhanced computed tomographic (CT) scanning, radionuclide brain scanning, or a combination of both techniques. In 56 procedures (19 patients) monitored by enhanced CT, seizures occurred a total of 10 times in eight patients. Twenty-three barrier modification procedures (in nine of these 19 patients) documented by nuclear brain scans alone, however, resulted in only one focal motor seizure in each of two patients. In eight of the 19 patients who had seizures after barrier disruption and enhanced CT scan, four subsequently had repeat procedures monitored by radionuclide scan alone. In only one of these patients was further seizure activity noted; a single focal motor seizure was observed. Clearly, the radionuclide brain scan does not have the sensitivity and spatial resolution of enhanced CT, but at present it appears safer to monitor barrier modification by this method and to follow tumor growth between barrier modifications by enhanced CT. Four illustrative cases showing methods, problems, and promising results are presented

  6. Emittance scans for CMS luminosity calibration in 2017

    CERN Document Server

    CMS Collaboration

    2018-01-01

    Emittance scans are short van der Meer type scans performed at the beginning and at the end of LHC fills. The beams are scanned against each other in X and Y planes in 7 displacement steps. These scans are used for LHC diagnostics and since 2017 for a cross check of the CMS luminosity calibration. An XY pair of scans takes around 3 minutes. The BRIL project provides to LHC three independent online luminosity measurement from the Pixel Luminosity Telescope (PLT), the Fast Beam Condition Monitor (BCM1F) and the Forward calorimeter (HF). The excellent performance of the BRIL detector front-ends, fast back-end electronics and CMS XDAQ based data processing and publication allow the use of emittance scans for linearity and stability studies of the luminometers. Emittance scans became a powerful tool and dramatically improved the understanding of the luminosity measurement during the year. Since each luminometer is independently calibrated in every scan the measurements are independent and ratios of luminometers ca...

  7. Minimising medically unwarranted computed tomography scans

    International Nuclear Information System (INIS)

    Brenner, D.J.

    2012-01-01

    As computed tomography (CT) is such a superb diagnostic tool and individual CT risks are small, whenever a CT scan is clinically warranted, the CT benefit/risk balance is by far in the patient’s favour. However, if a CT scan is not clinically warranted, this balance shifts dramatically. It is likely that at least 25% of CT scans fall into this latter category, in that they could either be replaced with alternative imaging modalities or could be avoided entirely. Use of clinical decision rules for CT usage represents a powerful approach for slowing down the increase in CT usage, because they have the potential to overcome some of the major factors that result in some CT scans being undertaken when they may not be clinically helpful.

  8. Technical errors in planar bone scanning.

    Science.gov (United States)

    Naddaf, Sleiman Y; Collier, B David; Elgazzar, Abdelhamid H; Khalil, Magdy M

    2004-09-01

    Optimal technique for planar bone scanning improves image quality, which in turn improves diagnostic efficacy. Because planar bone scanning is one of the most frequently performed nuclear medicine examinations, maintaining high standards for this examination is a daily concern for most nuclear medicine departments. Although some problems such as patient motion are frequently encountered, the degraded images produced by many other deviations from optimal technique are rarely seen in clinical practice and therefore may be difficult to recognize. The objectives of this article are to list optimal techniques for 3-phase and whole-body bone scanning, to describe and illustrate a selection of deviations from these optimal techniques for planar bone scanning, and to explain how to minimize or avoid such technical errors.

  9. Substernal thyroid carcinoma detected by 67Ga scan in a patient with normal 131I scan

    International Nuclear Information System (INIS)

    Kim, e.E.; Maruyama, Y.; Deland, F.H.

    1978-01-01

    A patient with a superior mediastinal mass on an admission chest radiograph was initially evaluated by an 131 I thyroid scan which failed to demonstrate a substernal thyroid. However, the tomographic 67 Ga scan clearly showed an abnormal uptake in the area corresponding to the mass lesion on radiographic examination. Subsequent resection and biopsy of the substernal mass revealed a poorly differentiated follicular carcinoma with foci of anaplastic carcinoma. The differential diagnosis of the anterior mediastinal mass and the usefullness of the tomographic gallium scan are briefly discussed

  10. Multiple bony lesions other than femoral heads on {sup 99m}Tc-MDP bone scan in patients with avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yun Young; Yang, Seoung Oh; Moon, Dae Hyuk; Ryu, Jin Sook; Weon, Young Cheol; Shin, Myung Jin; Lee, Soo Ho; Lee, Hee Kyung [Asan Medical Center, Ulsan Univ. College of Medicine, Ulsan (Korea, Republic of); Chun, Hae Kyung [St. Francisco Hospital, Seoul (Korea, Republic of)

    1997-03-01

    To evaluate the clinical significance of the multiple increased uptake lesions other than in femoral heads as seen on whole body bone scan in patients with avascular necrosis of femoral heads. One hundred and seventy three patients with clinical diagnosis of avascular necrosis of the emoral head underwent a bone scan using Tc-99m MDP. Increased uptake lesions other than in femoral heads were evaluated, including frequency and common sites of in volvement, and correlated with clinical information and plain radiographic findings. Two hundred patients without AVN, who had undergone a bone scan, were included as a control group. Increased uptake lesions in extrafemoral head locations were found in 36 of 173 patients(20.8%); the location of 79 lesions was other than the femoral head. This result is statistically different from patients without avascular necrosis of femoral head(p<0.0001). The most common site of involvement was the knee joint area(62.5%). Other lesions were located in the mid-shafts of the long bones of the lower extremities, calcaneus, proximal humerus, etc., in order of decreasing frequency. Plain radiographs of 17 lesions were nonspecific, except for three lesions showing definite changes associated with avascular necrosis. The risk factors included alcoholism, the prolonged use of steroids, renal transplantation, herbal medication and working as a working as deep-sea diver. Most patients did not complain of pain, except for two with irreversible osteonecrotic changes as seen on plain radiograph. in patients with avascular necrosis of the femur, increased uptake lesions other than in the femoral head as seen on bone scan, may represent the early stage of osteonecrosis, which shows a characteristic appearance on bone scan. In order to aveid possible misdiagnoses of multiple extrafemoral lesions as bony metastasis or traumatic lesions, in patients with avascular necrosis of the femur these should be carefully evaluated.

  11. 18F-PET imaging: frequency, distribution and appearance of benign lesions

    International Nuclear Information System (INIS)

    Schirrmeister, H.; Kotzerke, J.; Rentschler, M.; Traeger, H.; Fenchel, S.; Diederichs, C.G.; Reske, S.N.; Nuessle, K.

    1998-01-01

    Purpose: We evaluated the frequency, distribution and appearance of benign lesions in 18 F-PET scans. Methods: Between March 1996 and May 1997, 18 F-PET scans were performed in 59 patients in addition to conventional planar bone scintigraphy. Eleven patients were subjected to additional SPECT imaging. The main indication was searching for bone metastases (58 pat.). The diagnosis was confirmed radiologically. Results: With 18 F-PET in 39 patients (66,1%) 152 benign lesions, mostly located in the spine were detected. 99m Tc bone scans revealed 45 lesions in 10 patients. Osteoarthritis of the intervertebral articulations (69%) or of the acromioclavicular joint (15%) were the most common reasons for degenerative lesions detected with 18 F-PET. Osteophytes appeared as hot lesions located at two adjacent vertebral endplates. Osteoarthritis of the intervertebral articulations showed an enhanced tracer uptake at these localizations, whereas endplate fractures of the vertebral bodies appeared very typically; solitary fractures of the ribs could not be differentiated from metastases. Rare benign lesions were not studied. Conclusion: Most of the degenerative lesions (84%) detected with 18 F-PET had a very typical appearance and could be detected with the improved spatial resolution and advantages of a tomographic technique. 18 F-PET had an increased accuracy in detecting degenerative bone lesions. (orig.) [de

  12. A new flexible monochromator setup for quick scanning x-ray absorption spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Stoetzel, J.; Luetzenkirchen-Hecht, D.; Frahm, R. [Fachbereich C, Physik, Bergische Universitaet Wuppertal, Gaussstr. 20, 42097 Wuppertal (Germany)

    2010-07-15

    A new monochromator setup for quick scanning x-ray absorption spectroscopy in the subsecond time regime is presented. Novel driving mechanics allow changing the energy range of the acquired spectra by remote control during data acquisition for the first time, thus dramatically increasing the flexibility and convenience of this method. Completely new experiments are feasible due to the fact that time resolution, edge energy, and energy range of the acquired spectra can be changed continuously within seconds without breaking the vacuum of the monochromator vessel and even without interrupting the measurements. The advanced mechanics are explained in detail and the performance is characterized with x-ray absorption spectra of pure metal foils. The energy scale was determined by a fast and accurate angular encoder system measuring the Bragg angle of the monochromator crystal with subarcsecond resolution. The Bragg angle range covered by the oscillating crystal can currently be changed from 0 deg. to 3.0 deg. within 20 s, while the mechanics are capable to move with frequencies of up to ca. 35 Hz, leading to ca. 14 ms/spectrum time resolution. A new software package allows performing programmed scan sequences, which enable the user to measure stepwise with alternating parameters in predefined time segments. Thus, e.g., switching between edges scanned with the same energy range is possible within one in situ experiment, while also the time resolution can be varied simultaneously. This progress makes the new system extremely user friendly and efficient to use for time resolved x-ray absorption spectroscopy at synchrotron radiation beamlines.

  13. Development of an ultra wide band microwave radar based footwear scanning system

    Science.gov (United States)

    Rezgui, Nacer Ddine; Bowring, Nicholas J.; Andrews, David A.; Harmer, Stuart W.; Southgate, Matthew J.; O'Reilly, Dean

    2013-10-01

    At airports, security screening can cause long delays. In order to speed up screening a solution to avoid passengers removing their shoes to have them X-ray scanned is required. To detect threats or contraband items hidden within the shoe, a method of screening using frequency swept signals between 15 to 40 GHz has been developed, where the scan is carried out whilst the shoes are being worn. Most footwear is transparent to microwaves to some extent in this band. The scans, data processing and interpretation of the 2D image of the cross section of the shoe are completed in a few seconds. Using safe low power UWB radar, scattered signals from the shoe can be observed which are caused by changes in material properties such as cavities, dielectric or metal objects concealed within the shoe. By moving the transmission horn along the length of the shoe a 2D image corresponding to a cross section through the footwear is built up, which can be interpreted by the user, or automatically, to reveal the presence of concealed threat within the shoe. A prototype system with a resolution of 6 mm or less has been developed and results obtained for a wide range of commonly worn footwear, some modified by the inclusion of concealed material. Clear differences between the measured images of modified and unmodified shoes are seen. Procedures for enhancing the image through electronic image synthesis techniques and image processing methods are discussed and preliminary performance data presented.

  14. Three-dimensional scanning force/tunneling spectroscopy at room temperature

    International Nuclear Information System (INIS)

    Sugimoto, Yoshiaki; Ueda, Keiichi; Abe, Masayuki; Morita, Seizo

    2012-01-01

    We simultaneously measured the force and tunneling current in three-dimensional (3D) space on the Si(111)-(7 × 7) surface using scanning force/tunneling microscopy at room temperature. The observables, the frequency shift and the time-averaged tunneling current were converted to the physical quantities of interest, i.e. the interaction force and the instantaneous tunneling current. Using the same tip, the local density of states (LDOS) was mapped on the same surface area at constant height by measuring the time-averaged tunneling current as a function of the bias voltage at every lateral position. LDOS images at negative sample voltages indicate that the tip apex is covered with Si atoms, which is consistent with the Si-Si covalent bonding mechanism for AFM imaging. A measurement technique for 3D force/current mapping and LDOS imaging on the equivalent surface area using the same tip was thus demonstrated. (paper)

  15. Magnetically scanned proton therapy beams: rationales and techniques

    International Nuclear Information System (INIS)

    Jones, D.T.L.; Schreuder, A.N.

    2000-01-01

    Perhaps the most important advantages of beam scanning systems for proton therapy in comparison with conventional passive beam spreading systems are: (1) Intensity modulation and inverse planning are possible. (2) There is negligible reduction in the range of the beam. (3) Integral dose is reduced as dose conformation to the proximal edge of the lesion is possible. (4) In principle no field-specific modifying devices are required. (5) There is less activation of the surroundings. (6) Scanning systems axe almost infinitely flexible. The main disadvantages include: (1) Scanning systems are more complicated and therefore potentially less reliable and more dangerous. (2) The development of such systems is more demanding in terms of cost, time and manpower. (3) More stable beams are required. (4) Dose and beam position monitoring are more difficult. (5) The problems associated with patient and organ movement axe more severe. There are several techniques which can be used for scanning. For lateral beam spreading, circular scanning (wobbling) or linear scanning can be done. In the latter case the beam can be scanned continuously or in a discrete fashion (spot scanning). Another possibility is to undertake the fastest scan in one dimension (strip scanning) and translate the patient or the scanning magnet in the other dimension. Depth variation is achieved by interposing degraders in the beam (cyclotrons) or by changing the beam energy (synchrotrons). The aim of beam scanning is to deliver a predetermined dose at any point in the body. Special safety precautions must be taken because of the high instantaneous dose rates. The beam position and the dose delivered at each point must be accurately and redundantly determined. (author)

  16. Feedback/feedforward control of hysteresis-compensated piezoelectric actuators for high-speed scanning applications

    International Nuclear Information System (INIS)

    Liu, Yanfang; Shan, Jinjun; Gabbert, Ulrich

    2015-01-01

    This paper presents the control system design for a piezoelectric actuator (PEA) for a high-speed trajectory scanning application. First nonlinear hysteresis is compensated for by using the Maxwell resistive capacitor model. Then the linear dynamics of the hysteresis-compensated piezoelectric actuator are identified. A proportional plus integral (PI) controller is designed based on the linear system, enhanced by feedforward hysteresis compensation. It is found that the feedback controller does not always improve tracking accuracy. When the input frequency exceeds a certain value, feedforward control only may result in better control performance. Experiments are conducted, and the results demonstrate the effectiveness of the proposed control approach. (paper)

  17. An elastography method based on the scanning contact resonance of a piezoelectric cantilever

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Ji; Li, Faxin, E-mail: lifaxin@pku.edu.cn [State Key Lab for Turbulence and Complex Systems, College of Engineering, Peking University, Beijing 100871, China and HEDPS, Center for Applied Physics and Technologies, Peking University, Beijing 100871 (China)

    2013-12-15

    Purpose: Most tissues may become significantly stiffer than their normal states when there are lesions inside. The tissue's modulus can then act as an identification parameter for clinic diagnosis of tumors or fibrosis, which leads to elastography. This study introduces a novel elastography method that can be used for modulus imaging of superficial organs. Methods: This method is based on the scanning contact-resonance of a unimorph piezoelectric cantilever. The cantilever vibrates in its bending mode with the tip pressed tightly on the sample. The contact resonance frequency of the cantilever-sample system is tracked at each scanning point, from which the sample's modulus can be derived based on a beam dynamic model and a contact mechanics model. Scanning is performed by a three-dimensional motorized stage and the whole system is controlled by a homemade software program based on LabVIEW. Results: Testing onin vitro beef tissues indicates that the fat and the muscle can be easily distinguished using this system, and the accuracy of the modulus measurement can be comparable with that of nanoindentation. Imaging on homemade gelatin phantoms shows that the depth information of the abnormalities can be qualitatively obtained by varying the pressing force. The detection limit of this elastography method is specially examined both experimentally and numerically. Results show that it can detect the typical lesions in superficial organs with the depth of several centimeters. The lateral resolution of this elastography method/system is better than 0.5 mm, and could be further enhanced by using more scanning points. Conclusions: The proposed elastography system can be regarded as a sensitive palpation robot, which may be very promising in early diagnosis of tumors in superficial organs such as breast and thyroid.

  18. An elastography method based on the scanning contact resonance of a piezoelectric cantilever.

    Science.gov (United States)

    Fu, Ji; Li, Faxin

    2013-12-01

    Most tissues may become significantly stiffer than their normal states when there are lesions inside. The tissue's modulus can then act as an identification parameter for clinic diagnosis of tumors or fibrosis, which leads to elastography. This study introduces a novel elastography method that can be used for modulus imaging of superficial organs. This method is based on the scanning contact-resonance of a unimorph piezoelectric cantilever. The cantilever vibrates in its bending mode with the tip pressed tightly on the sample. The contact resonance frequency of the cantilever-sample system is tracked at each scanning point, from which the sample's modulus can be derived based on a beam dynamic model and a contact mechanics model. Scanning is performed by a three-dimensional motorized stage and the whole system is controlled by a homemade software program based on LabVIEW. Testing on in vitro beef tissues indicates that the fat and the muscle can be easily distinguished using this system, and the accuracy of the modulus measurement can be comparable with that of nanoindentation. Imaging on homemade gelatin phantoms shows that the depth information of the abnormalities can be qualitatively obtained by varying the pressing force. The detection limit of this elastography method is specially examined both experimentally and numerically. Results show that it can detect the typical lesions in superficial organs with the depth of several centimeters. The lateral resolution of this elastography method∕system is better than 0.5 mm, and could be further enhanced by using more scanning points. The proposed elastography system can be regarded as a sensitive palpation robot, which may be very promising in early diagnosis of tumors in superficial organs such as breast and thyroid.

  19. Towards vortex imaging with scanning tunneling microscope

    International Nuclear Information System (INIS)

    Fuchs, Dan T.

    1994-02-01

    A low temperature, Besocke beetle type scanning tunneling microscope, with a scan range of 10 by 10 microns was built. The scanning tunneling microscope was calibrates for various temperatures and tested on several samples. Gold monolayers evaporated at 400 deg C were resolved and their dynamic behavior observed. Atomic resolution images of graphite were obtained. The scanning tunneling microscope was designed for future applications of vortex imaging in superconductors. The special design considerations for this application are discussed and the physics underlying it reviewed. (author)

  20. Scanning Tunneling Microscope For Use In Vacuum

    Science.gov (United States)

    Abel, Phillip B.

    1993-01-01

    Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.

  1. Efficiency of a concentric matrix track detector surface scanning

    International Nuclear Information System (INIS)

    Bek-Uzarov, Dj.; Nikezic, D.; Kostic, D.; Krstic, D.; Cuknic, O.

    1995-01-01

    Heavy particle ionizing radiation track counting on the surface of a solid state round surface detector is made using the microscope and scanning step by step by a round field of vision. The whole solid state detector surface could not be fully or completely covered by round fields of visions. Therefore detector surface could be divided on the two parts, the larger surface, being under fields of vision, really scanned and no scanned missed or omitted surface. The ratio between omitted and scanned surfaces is so called track scanning efficiency. The knowledge of really counted, or scanned surface is a important value for evaluating the real surface track density an exposed solid state track detector. In the paper a matrix of a concentric field of vision made around the first microscope field of vision placed in center of the round disc of the scanned track detector is proposed. In a such scanning matrix the real scanned surface could be easy calculated and by the microscope scanning made as well. By this way scanned surface is very precisely obtained as well. Precise knowledge of scanned and omitted surface allows to obtain more precise scanning efficiency factor as well as real surface track density, the main parameter in solid state track detection measurements. (author)

  2. Linking world scan and image

    International Nuclear Information System (INIS)

    Timmer, H.; Alcamo, J.; Bollen, J.; Gielen, A.; Gerlach, R.; Den Ouden, A.; Zuidema, G.

    1995-01-01

    In march 1994 the Central Planning Bureau (CPB) in the Hague, the National Institute of Public Health and Environmental Protection (RIVM) in Bilthoven and the Institute of Environmental Studies (IES) in Amsterdam started the first phase of a joint research program aimed at creating integrated scenarios of the global economy, GHG emissions, and climate impacts. The goal of the first phase of this project was to design and test a linked version of the economic model WORLD SCAN of the former, and the climate model IMAGE 2 of the latter institute. This first phase has resulted in the planned test runs with an operational version of the linked models by May 1995. The experiences in the first year were encouraging, both in the scientific and the organizational sense. In a sense, a link was made between scientific disciplines: a coupling of disciplines concerning with global economic development and the global physical climate system is difficult and novel. The goal of the project was to integrate long-term economic developments and effects of climate change. Both the WORLD SCAN model and IMAGE 2 provide a consistent analysis of the global system, but from different perspectives. IMAGE 2 simulates climate change and its effects in a global context but treats the economic system as exogenous. WORLD SCAN covers the world economic system in a consistent manner but does not take into account the global environment. The links are constructed in the area of agriculture and energy. The basic idea is that WORLD SCAN determines demand and supply on economic principles, while IMAGE 2 provides information on changes of land area and average quality of productive land, and other damage costs based on its three sub-systems. The demand for energy is fed into IMAGE 2's Energy Industry subsystem (EIS), which in turn determines emissions of greenhouse gases. Furthermore, some additional output from WORLD SCAN on activity levels, prices and capital structure can be used to determine

  3. An ultrahigh vacuum fast-scanning and variable temperature scanning tunneling microscope for large scale imaging.

    Science.gov (United States)

    Diaconescu, Bogdan; Nenchev, Georgi; de la Figuera, Juan; Pohl, Karsten

    2007-10-01

    We describe the design and performance of a fast-scanning, variable temperature scanning tunneling microscope (STM) operating from 80 to 700 K in ultrahigh vacuum (UHV), which routinely achieves large scale atomically resolved imaging of compact metallic surfaces. An efficient in-vacuum vibration isolation and cryogenic system allows for no external vibration isolation of the UHV chamber. The design of the sample holder and STM head permits imaging of the same nanometer-size area of the sample before and after sample preparation outside the STM base. Refractory metal samples are frequently annealed up to 2000 K and their cooldown time from room temperature to 80 K is 15 min. The vertical resolution of the instrument was found to be about 2 pm at room temperature. The coarse motor design allows both translation and rotation of the scanner tube. The total scanning area is about 8 x 8 microm(2). The sample temperature can be adjusted by a few tens of degrees while scanning over the same sample area.

  4. Huffman and linear scanning methods with statistical language models.

    Science.gov (United States)

    Roark, Brian; Fried-Oken, Melanie; Gibbons, Chris

    2015-03-01

    Current scanning access methods for text generation in AAC devices are limited to relatively few options, most notably row/column variations within a matrix. We present Huffman scanning, a new method for applying statistical language models to binary-switch, static-grid typing AAC interfaces, and compare it to other scanning options under a variety of conditions. We present results for 16 adults without disabilities and one 36-year-old man with locked-in syndrome who presents with complex communication needs and uses AAC scanning devices for writing. Huffman scanning with a statistical language model yielded significant typing speedups for the 16 participants without disabilities versus any of the other methods tested, including two row/column scanning methods. A similar pattern of results was found with the individual with locked-in syndrome. Interestingly, faster typing speeds were obtained with Huffman scanning using a more leisurely scan rate than relatively fast individually calibrated scan rates. Overall, the results reported here demonstrate great promise for the usability of Huffman scanning as a faster alternative to row/column scanning.

  5. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  6. Laser Doppler vibrometry on rotating structures in coast-down: resonance frequencies and operational deflection shape characterization

    International Nuclear Information System (INIS)

    Martarelli, M; Castellini, P; Santolini, C; Tomasini, E P

    2011-01-01

    In rotating machinery, variations of modal parameters with rotation speed may be extremely important in particular for very light and undamped structures, such as helicopter rotors or wind turbines. The natural frequency dependence on rotation speed is conventionally measured by varying the rotor velocity and plotting natural frequencies versus speed in the so-called Campbell diagram. However, this kind of analysis does not give any information about the vibration spatial distribution i.e. the mode shape variation with the rotation speed must be investigated with dedicated procedures. In several cases it is not possible to fully control the rotating speed of the machine and only coast-down tests can be performed. Due to the reduced inertia of rotors, the coast-down process is usually an abrupt transient and therefore an experimental technique, able to determine operational deflection shapes (ODSs) in short time, with high spatial density and accuracy, appears very promising. Moreover coast-down processes are very difficult to control, causing unsteady vibrations. Hence, a very efficient approach for the rotation control and synchronous acquisition must be developed. In this paper a continuous scanning system able to measure ODSs and natural frequencies excited during rotor coast-down is shown. The method is based on a laser Doppler vibrometer (LDV) whose laser beam is driven to scan continuously over the rotor surface, in order to measure the ODS, and to follow the rotation of the rotor itself even in coast-down. With a single measurement the ODSs can be recovered from the LDV output time history in short time and with huge data saving. This technique has been tested on a laboratory test bench, i.e. a rotating two-blade fan, and compared with a series of non-contact approaches based on LDV: - traditional experimental modal analysis (EMA) results obtained under non-rotating conditions by measuring on a sequence of points on the blade surface excited by an impact

  7. Tumor scanning with /sup 57/Co-bleomycin

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, S; Hasegawa, Y; Matsuda, Minoru; Ho, T; Doi, O [Osaka Prefectural Center for Adult Diseases (Japan)

    1975-06-01

    The clinical application of /sup 57/Co-bleomycin as a tumor scanning radiopharmaceutical was firstly reported by Nouel and Maeda respectively. The authors conducted studies on the diagnostic significance of this tumor scanning agent and presented the results obtained in 40 patients with malignant and non malignant lesions. Six hours and 24 hours after the injection of 500 ..mu..Ci of /sup 57/Co-bleomycin, scintigrams were taken with a 3-inch scintiscanner. Positive scans were found in 20 out of 36 patients with various malignant tumors. Of 20 patients with lung cancer, positive scans were obtained in 17 cases (85%) and of 6 with breast cancer, 3 cases showed positive scans. False negative scans were obtained in another 10 cases of malignant tumors (3 cases of thyroid carcinoma, 4 cases of hepatoma, and 1 case each of gastric carcinoma, peritoneal carcinomatosis, and reticulum cell sarcoma). Of 4 patients with non malignant disease, one case of pulmonary tuberculosis showed a positive scan. In 8 cases of lung cancer and 6 of breast cancer, the relationship between the size of the excised tumor and the scintigram findings was studied. The smallest tumors detected by scintigram were 2 cm in lung cancer and 3.2 cm in breast cancer.

  8. Radionuclide scan findings in delayed splenic rupture

    International Nuclear Information System (INIS)

    Flickinger, F.W.; Jackson, G.L.

    1978-01-01

    An initial liver/spleen scan performed on a patient with blunt abdominal trauma was negative 3 days following the accident. A follow-up scan 7 days later showed definite evidence of splenic rupture, proved surgically. The authors conclude that, in such cases, spleen scans may be negative initially because of delayed splenic ruptures

  9. RisøScan - a new dosimetry software

    DEFF Research Database (Denmark)

    Helt-Hansen, J.; Miller, A.

    2004-01-01

    RisoScan is a software package that is used for analysis of images of visibly coloured dosimeter films. The image is created by scanning the dosimeter film on a flatbed scanner. RisoScan is based on LabView(R), and it is useful for analysis of dose distributions and depth dose curves. Measurement...

  10. SU-F-T-173: One-Scan Protocol: Verifying the Delivery of Spot-Scanning Proton Beam

    Energy Technology Data Exchange (ETDEWEB)

    Chan, M; Li, J [Memorial Sloan-Kettering Cancer Center, Basking Ridge, NJ (United States); Chen, C; Mah, D [Procure Treatment Center, Somerset, NJ (United States); Tang, X [Memorial Sloan Kettering Cancer Center, West Harrison, NY (United States); Li, X [Memorial Sloan Kettering Cancer Center, Rockville Centre, NY (United States); Tang, G [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient. We present a one-scan protocol to simplify the procedure. Methods: We performed the calibration using an EBT3 film at depths of 18, 20, 24cm of Plastic Water exposed by a 6-level step-wedge plan on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged 65–250 cGy(RBE) for proton energies of 170–200MeV. A clinical prostate+nodes plan was used for validation. The planar doses at selected depths were measured with EBT3 films and analyzed using one-scan protocol (one-scan digitization of QA film and at least one film exposed to known dose). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film, IBA MatriXX PT, versus TPS calculations were analyzed and compared. Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate of ∼95% for 2%/2mm and slightly lower passing rates were obtained from an ion chamber array detector. We were able to demonstrate that the use of a proton step-wedge provided clinically acceptable results and minimized variations between film-scanner orientation, inter-scan, and scanning conditions. Furthermore, it could be derived from no more than two films exposed to known doses (one could be zero) for rescaling the master calibration curve at each depth. Conclusion: The use of a proton step-wedge for calibration of EBT3 film increases efficiency. The sensitivity of the calibration to depth variations has been explored. One-scan protocol results appear to be comparable to that of the ion chamber array detector. One author has a research grant from

  11. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  12. Developing optimized CT scan protocols: Phantom measurements of image quality

    International Nuclear Information System (INIS)

    Zarb, Francis; Rainford, Louise; McEntee, Mark F.

    2011-01-01

    Purpose: The increasing frequency of computerized tomography (CT) examinations is well documented, leading to concern about potential radiation risks for patients. However, the consequences of not performing the CT examination and missing injuries and disease are potentially serious, impacting upon correct patient management. The ALARA principle of dose optimization must be employed for all justified CT examinations. Dose indicators displayed on the CT console as either CT dose index (CTDI) and/or dose length product (DLP), are used to indicate dose and can quantify improvements achieved through optimization. Key scan parameters contributing to dose have been identified in previous literature and in previous work by our group. The aim of this study was to optimize the scan parameters of mA; kV and pitch, whilst maintaining image quality and reducing dose. This research was conducted using psychophysical image quality measurements on a CT quality assurance (QA) phantom establishing the impact of dose optimization on image quality parameters. Method: Current CT scan parameters for head (posterior fossa and cerebrum), abdomen and chest examinations were collected from 57% of CT suites available nationally in Malta (n = 4). Current scan protocols were used to image a Catphan 600 CT QA phantom whereby image quality was assessed. Each scan parameter: mA; kV and pitch were systematically reduced until the contrast resolution (CR), spatial resolution (SR) and noise were significantly lowered. The Catphan 600 images, produced by the range of protocols, were evaluated by 2 expert observers assessing CR, SR and noise. The protocol considered as the optimization threshold was just above the setting that resulted in a significant reduction in CR and noise but not affecting SR at the 95% confidence interval. Results: The limit of optimization threshold was determined for each CT suite. Employing optimized parameters, CTDI and DLP were both significantly reduced (p ≤ 0.001) by

  13. Confocal scanning microscope for nuclear photoemulsion

    International Nuclear Information System (INIS)

    Batusov, Yu.A.; Kovalev, Yu.S.; Soroko, L.M.

    2005-01-01

    The application of the confocal scanning microscope to the objects in the nuclear photoemulsion is described. An array of 27 microtomograms of single silver grain is shown. The cross sections of the same particle track of diameter 1 μm, detected by means of the confocal scanning microscope with open and annular apertures, are presented. It was shown that the confocal scanning microscope opens indeed new opportunities for the nuclear photoemulsion technique to get previously inaccessible information for physics of the short-living particles

  14. En face speckle reduction in optical coherence microscopy by frequency compounding.

    Science.gov (United States)

    Magnain, Caroline; Wang, Hui; Sakadžić, Sava; Fischl, Bruce; Boas, David A

    2016-05-01

    We report the use of frequency compounding to significantly reduce speckle noise in optical coherence microscopy, more specifically on the en face images. This method relies on the fact that the speckle patterns recorded from different wavelengths simultaneously are independent; hence their summation yields significant reduction in noise, with only a single acquisition. The results of our experiments with microbeads show that the narrow confocal parameter, due to a high numerical aperture objective, restricts the axial resolution loss that would otherwise theoretically broaden linearly with the number of optical frequency bands used. This speckle reduction scheme preserves the lateral resolution since it is performed on individual A-scans. Finally, we apply this technique to images of fixed human brain tissue, showing significant improvements in contrast-to-noise ratio with only moderate loss of axial resolution, in an effort to improve automatic three-dimensional detection of cells and fibers in the cortex.

  15. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  16. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  17. Absolute frequency atlas from 915 nm to 985 nm based on laser absorption spectroscopy of iodine

    Science.gov (United States)

    Nölleke, Christian; Raab, Christoph; Neuhaus, Rudolf; Falke, Stephan

    2018-04-01

    This article reports on laser absorption spectroscopy of iodine gas between 915 nm and 985 nm. This wavelength range is scanned utilizing a narrow linewidth and mode-hop-free tunable diode-laser whose frequency is actively controlled using a calibrated wavelength meter. This allows us to provide an iodine atlas that contains almost 10,000 experimentally observed reference lines with an uncertainty of 50 MHz. For common lines, good agreement is found with a publication by Gerstenkorn and Luc (1978). The new rich dataset allows existing models of the iodine molecule to be refined and can serve as a reference for laser frequency calibration and stabilization.

  18. Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

    International Nuclear Information System (INIS)

    Gholipour, Ali; Afacan, Onur; Scherrer, Benoit; Prabhu, Sanjay P.; Warfield, Simon K.; Aganj, Iman; Sahin, Mustafa

    2015-01-01

    Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in

  19. Super-resolution reconstruction in frequency, image, and wavelet domains to reduce through-plane partial voluming in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gholipour, Ali, E-mail: ali.gholipour@childrens.harvard.edu; Afacan, Onur; Scherrer, Benoit; Prabhu, Sanjay P.; Warfield, Simon K. [Department of Radiology, Boston Children’s Hospital, Boston, Massachusetts 02115 and Harvard Medical School, Boston, Massachusetts 02115 (United States); Aganj, Iman [Radiology Department, Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts 02129 and Harvard Medical School, Boston, Massachusetts 02115 (United States); Sahin, Mustafa [Department of Neurology, Boston Children’s Hospital, Boston, Massachusetts 02115 and Harvard Medical School, Boston, Massachusetts 02115 (United States)

    2015-12-15

    Purpose: To compare and evaluate the use of super-resolution reconstruction (SRR), in frequency, image, and wavelet domains, to reduce through-plane partial voluming effects in magnetic resonance imaging. Methods: The reconstruction of an isotropic high-resolution image from multiple thick-slice scans has been investigated through techniques in frequency, image, and wavelet domains. Experiments were carried out with thick-slice T2-weighted fast spin echo sequence on the Academic College of Radiology MRI phantom, where the reconstructed images were compared to a reference high-resolution scan using peak signal-to-noise ratio (PSNR), structural similarity image metric (SSIM), mutual information (MI), and the mean absolute error (MAE) of image intensity profiles. The application of super-resolution reconstruction was then examined in retrospective processing of clinical neuroimages of ten pediatric patients with tuberous sclerosis complex (TSC) to reduce through-plane partial voluming for improved 3D delineation and visualization of thin radial bands of white matter abnormalities. Results: Quantitative evaluation results show improvements in all evaluation metrics through super-resolution reconstruction in the frequency, image, and wavelet domains, with the highest values obtained from SRR in the image domain. The metric values for image-domain SRR versus the original axial, coronal, and sagittal images were PSNR = 32.26 vs 32.22, 32.16, 30.65; SSIM = 0.931 vs 0.922, 0.924, 0.918; MI = 0.871 vs 0.842, 0.844, 0.831; and MAE = 5.38 vs 7.34, 7.06, 6.19. All similarity metrics showed high correlations with expert ranking of image resolution with MI showing the highest correlation at 0.943. Qualitative assessment of the neuroimages of ten TSC patients through in-plane and out-of-plane visualization of structures showed the extent of partial voluming effect in a real clinical scenario and its reduction using SRR. Blinded expert evaluation of image resolution in

  20. A scanning probe microscope for magnetoresistive cantilevers utilizing a nested scanner design for large-area scans

    Directory of Open Access Journals (Sweden)

    Tobias Meier

    2015-02-01

    Full Text Available We describe an atomic force microscope (AFM for the characterization of self-sensing tunneling magnetoresistive (TMR cantilevers. Furthermore, we achieve a large scan-range with a nested scanner design of two independent piezo scanners: a small high resolution scanner with a scan range of 5 × 5 × 5 μm3 is mounted on a large-area scanner with a scan range of 800 × 800 × 35 μm3. In order to characterize TMR sensors on AFM cantilevers as deflection sensors, the AFM is equipped with a laser beam deflection setup to measure the deflection of the cantilevers independently. The instrument is based on a commercial AFM controller and capable to perform large-area scanning directly without stitching of images. Images obtained on different samples such as calibration standard, optical grating, EPROM chip, self-assembled monolayers and atomic step-edges of gold demonstrate the high stability of the nested scanner design and the performance of self-sensing TMR cantilevers.

  1. Overview of the low energy accelerator scanning system

    International Nuclear Information System (INIS)

    Leo Kwee Wah; Lojius Lombigit; Muhamad Zahidee Taat; Abu Bakar Ghazali; Mohd Rizal Ibrahim; Mohd Rizal Chulan Md Chulan; Azaman Ahmad; Abdul Halim Baijan; Rokiah Mohd Sabri

    2009-01-01

    This paper describes the specification of the low energy accelerator (Baby-EBM; Electron Beam Machine) scanning system. It comprises a discussion of coil inductance measurement, power supply design and the test results. The scanning horn system was completely assembled and tested; it was found that the system is able to scan the beam across the scanning window with a required beam profile. (Author)

  2. Heart CT scan

    Science.gov (United States)

    ... make to decrease the risk of heart disease. Risks Risks of CT scans include: Being exposed to ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  3. MONTE CARLO SIMULATION OF MULTIFOCAL STOCHASTIC SCANNING SYSTEM

    Directory of Open Access Journals (Sweden)

    LIXIN LIU

    2014-01-01

    Full Text Available Multifocal multiphoton microscopy (MMM has greatly improved the utilization of excitation light and imaging speed due to parallel multiphoton excitation of the samples and simultaneous detection of the signals, which allows it to perform three-dimensional fast fluorescence imaging. Stochastic scanning can provide continuous, uniform and high-speed excitation of the sample, which makes it a suitable scanning scheme for MMM. In this paper, the graphical programming language — LabVIEW is used to achieve stochastic scanning of the two-dimensional galvo scanners by using white noise signals to control the x and y mirrors independently. Moreover, the stochastic scanning process is simulated by using Monte Carlo method. Our results show that MMM can avoid oversampling or subsampling in the scanning area and meet the requirements of uniform sampling by stochastically scanning the individual units of the N × N foci array. Therefore, continuous and uniform scanning in the whole field of view is implemented.

  4. Evaluation of 111In leukocyte whole body scanning

    International Nuclear Information System (INIS)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-01-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with 111 In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes

  5. Accelerated pharmacokinetic map determination for dynamic contrast enhanced MRI using frequency-domain based Tofts model.

    Science.gov (United States)

    Vajuvalli, Nithin N; Nayak, Krupa N; Geethanath, Sairam

    2014-01-01

    Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) is widely used in the diagnosis of cancer and is also a promising tool for monitoring tumor response to treatment. The Tofts model has become a standard for the analysis of DCE-MRI. The process of curve fitting employed in the Tofts equation to obtain the pharmacokinetic (PK) parameters is time-consuming for high resolution scans. Current work demonstrates a frequency-domain approach applied to the standard Tofts equation to speed-up the process of curve-fitting in order to obtain the pharmacokinetic parameters. The results obtained show that using the frequency domain approach, the process of curve fitting is computationally more efficient compared to the time-domain approach.

  6. Low frequency phase signal measurement with high frequency squeezing

    OpenAIRE

    Zhai, Zehui; Gao, Jiangrui

    2011-01-01

    We calculate the utility of high-frequency squeezed-state enhanced two-frequency interferometry for low-frequency phase measurement. To use the high-frequency sidebands of the squeezed light, a two-frequency intense laser is used in the interferometry instead of a single-frequency laser as usual. We find that the readout signal can be contaminated by the high-frequency phase vibration, but this is easy to check and avoid. A proof-of-principle experiment is in the reach of modern quantum optic...

  7. Selenomethionine Se 75 thymus scans in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Toole, J.F.; Cowan, R.; Maynard, D.; Witcofski, R.L.; Janeway, R.

    1975-01-01

    In 1966, Toole and Witcofski introduced selenomethionine Se 75 mediastinal scanning as a diagnostic test for thymomas. Since then we have performed such scans on patients with myasthenic syndrome. Because the technique is atraumatic, safe, and accurate, it can be performed on critically ill myasthenics. Two hundred and fifty microcuries of selenomethionine Se 75 is injected intravenously. Within 1 hour the mediastinum from the suprasternal notch to the ziphoid process is scanned, using a 2 x 3 inch scanner. Delayed scans have been made in a few instances but they have not increased the number of positive cases. Selenomethionine Se 75 is incorporated into tissues undergoing rapid protein synthesis such as thyroid, pancreas, liver, and lymphomas. Of the 34 mediastinal scans performed on myasthenics between 1966 and December 31, 1974, 4 were positive for thymoma. In addition, there was a positive scan with uptake in an area of atelectasis of the lung adjacent to the mediastinum. Of interest is the fact that 1 patient with carcinoma of the lung had a positive scan over the lesion. In 13 patients with chronic lymphatic leukemia the mediastinal scans were negative. In another patient with a mediastinal mass noted on chest x-ray, a variety of differential diagnostic possibilities were considered, such as pericardial cyst, dermoid, and aneurysm. A selenomethionine scan was strongly positive, suggesting a thymoma which subsequent surgery confirmed.

  8. Clinical significant of three phase radionuclide bone scan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Hee; Suh, Jin Suck; Park, Chang Yun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1989-04-15

    Three phase radionuclide bone scan, consisting of a radionuclide angiogram, an immediate postinjection blood pool image, and 4hr delayed images, was randomly performed in 182 patients, who had been suffered from either local pain or tenderness. Authors analysed 3 phase bone scan in 74 patients with correct diagnosis proven surgically or clinically, from July 1987 to August, 1988. The results were as follows: 1. Overall sensitivity of 3 phase bone scan was 85.4%: sensitivity in patients with an osseous lesion was 90.4% as opposed to 72.7% in patients with a nonosseous lesion. 2. There was no difference in the detection rate of the osseous lesions between the 3 phase bone scan and the delayed image bone scan. However, because the detection rate was higher on the 3 phase bone scan than it was on only the delayed image bone scan (55%) in instance of the nonosseous lesion, we would suggest that 3 phase bone scan might be obtained in cases suspected of the nonosseous lesions. 3. When the presumptive diagnosis was a bone tumor, sensitivity and specificity for malignancy were 67%, 100% respectively. 4. In differentiating osteomyelitis from cellulitis, sensitivity was 94%, specificity was 100%. 5. 3 phase bone scan was able to provide the precise information about either vasculaturity or localization of lesion in some cases of soft tissue mass and avascular necrosis of hips.

  9. Enhanced resolution imaging of ultrathin ZnO layers on Ag(111) by multiple hydrogen molecules in a scanning tunneling microscope junction

    Science.gov (United States)

    Liu, Shuyi; Shiotari, Akitoshi; Baugh, Delroy; Wolf, Martin; Kumagai, Takashi

    2018-05-01

    Molecular hydrogen in a scanning tunneling microscope (STM) junction has been found to enhance the lateral spatial resolution of the STM imaging, referred to as scanning tunneling hydrogen microscopy (STHM). Here we report atomic resolution imaging of 2- and 3-monolayer (ML) thick ZnO layers epitaxially grown on Ag(111) using STHM. The enhanced resolution can be obtained at a relatively large tip to surface distance and resolves a more defective structure exhibiting dislocation defects for 3-ML-thick ZnO than for 2 ML. In order to elucidate the enhanced imaging mechanism, the electric and mechanical properties of the hydrogen molecular junction (HMJ) are investigated by a combination of STM and atomic force microscopy. It is found that the HMJ shows multiple kinklike features in the tip to surface distance dependence of the conductance and frequency shift curves, which are absent in a hydrogen-free junction. Based on a simple modeling, we propose that the junction contains several hydrogen molecules and sequential squeezing of the molecules out of the junction results in the kinklike features in the conductance and frequency shift curves. The model also qualitatively reproduces the enhanced resolution image of the ZnO films.

  10. Characterization of Ultrafast Laser Pulses using a Low-dispersion Frequency Resolved Optical Grating Spectrometer

    Science.gov (United States)

    Whitelock, Hope; Bishop, Michael; Khosravi, Soroush; Obaid, Razib; Berrah, Nora

    2016-05-01

    A low dispersion frequency-resolved optical gating (FROG) spectrometer was designed to characterize ultrashort (non-colinear optical parametric amplifier. This instrument splits a laser pulse into two replicas with a 90:10 intensity ratio using a thin pellicle beam-splitter and then recombines the pulses in a birefringent medium. The instrument detects a wavelength-sensitive change in polarization of the weak probe pulse in the presence of the stronger pump pulse inside the birefringent medium. Scanning the time delay between the two pulses and acquiring spectra allows for characterization of the frequency and time content of ultrafast laser pulses, that is needed for interpretation of experimental results obtained from these ultrafast laser systems. Funded by the DoE-BES, Grant No. DE-SC0012376.

  11. Whole body scan system based on γ camera

    International Nuclear Information System (INIS)

    Ma Tianyu; Jin Yongjie

    2001-01-01

    Most existing domestic γ cameras can not perform whole body scan protocol, which is of important use in clinic. The authors designed a set of whole body scan system, which is made up of a scan bed, an ISA interface card controlling the scan bed and the data acquisition software based on a data acquisition and image processing system for γ cameras. The image was obtained in clinical experiment, and the authors think it meets the need of clinical diagnosis. Application of this system in γ cameras can provide whole body scan function at low cost

  12. System and method for compressive scanning electron microscopy

    Science.gov (United States)

    Reed, Bryan W

    2015-01-13

    A scanning transmission electron microscopy (STEM) system is disclosed. The system may make use of an electron beam scanning system configured to generate a plurality of electron beam scans over substantially an entire sample, with each scan varying in electron-illumination intensity over a course of the scan. A signal acquisition system may be used for obtaining at least one of an image, a diffraction pattern, or a spectrum from the scans, the image, diffraction pattern, or spectrum representing only information from at least one of a select subplurality or linear combination of all pixel locations comprising the image. A dataset may be produced from the information. A subsystem may be used for mathematically analyzing the dataset to predict actual information that would have been produced by each pixel location of the image.

  13. A new scanning proton microprobe with long focus

    International Nuclear Information System (INIS)

    Zhu Jieqing; Li Minqian; Mao Yu; Chen Hanmin; Gu Yingmei; Yang Changyi; Sheng Kanglong

    1991-01-01

    A new scanning proton microprobe equipped with a long focus Russian magnetic quadruplet is set up. With excellent performances of ion optics, it can be used to do experiments of PIXE, RBS, RFS, NRA and channelling simultaneously within a micron-region. The power supplies for quadruplet and scanning coils are controlled by an IBM-PC computer and a scanning graphical monitor based on an Apple IIe microcomputer provides convenience of searching for an interesting area to scan. The advanced modes of the fast random scan and the event-by-event data collection make it possible to treat the multi-parameter and multi-detector data by means of the strategy of TQSA (Total quantitative scanning analysis). There are three types of graphical display including the innovation of three dimensional contour mapping

  14. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  15. Investigation of dielectric behavior of the PVC/BaTiO3 composite in low-frequencies

    Science.gov (United States)

    Berrag, A.; Belkhiat, S.; Madani, L.

    2018-04-01

    Polyvinyl chloride (PVC) is widely used as insulator in electrical engineering especially as cable insulation sheaths. In order to improve the dielectric properties, polymers are mixed with ceramics. In this paper, PVC composites with different weight percentages 2 wt.%, 5 wt.%, 8 wt.% and 10 wt.% were prepared and investigated. Loss index (𝜀″) and dielectric constant (𝜀‧) have been measured using an impedance analyzer RLC. Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) equipped with energy dispersive X-ray (EDX) have been used as characterization techniques. The incorporation of BaTiO3 does not modify the crystallinity and the morphology of the PVC but reduces the space charges, therefore the dielectric losses. The frequency response analysis has been followed in the frequency ranges (20-140 Hz and 115-1 MHz). Relaxation frequencies have been evaluated in each frequency range. Experimental measurements have been validated using Cole-Cole’s model. Experimental results show well that BaTiO3 as a filler improves the dielectric properties of PVC.

  16. Laser-Bioplasma Interaction: Excitation and Suppression of the Brain Waves by the Multi-photon Pulsed-operated Fiber Lasers in the Ultraviolet Range of Frequencies

    Science.gov (United States)

    Stefan, V. Alexander; IAPS-team Team

    2017-10-01

    The novel study of the laser excitation-suppression of the brain waves is proposed. It is based on the pulsed-operated multi-photon fiber-laser interaction with the brain parvalbumin (PV) neurons. The repetition frequency matches the low frequency brain waves (5-100 Hz); enabling the resonance-scanning of the wide range of the PV neurons (the generators of the brain wave activity). The tunable fiber laser frequencies are in the ultraviolet frequency range, thus enabling the monitoring of the PV neuron-DNA, within the 10s of milliseconds. In medicine, the method can be used as an ``instantaneous-on-off anesthetic.'' Supported by Nikola Tesla Labs, Stefan University.

  17. Adaptive Optical Scanning Holography

    Science.gov (United States)

    Tsang, P. W. M.; Poon, Ting-Chung; Liu, J.-P.

    2016-01-01

    Optical Scanning Holography (OSH) is a powerful technique that employs a single-pixel sensor and a row-by-row scanning mechanism to capture the hologram of a wide-view, three-dimensional object. However, the time required to acquire a hologram with OSH is rather lengthy. In this paper, we propose an enhanced framework, which is referred to as Adaptive OSH (AOSH), to shorten the holographic recording process. We have demonstrated that the AOSH method is capable of decreasing the acquisition time by up to an order of magnitude, while preserving the content of the hologram favorably. PMID:26916866

  18. Electron Beam Scanning in Industrial Applications

    Science.gov (United States)

    Jongen, Yves; Herer, Arnold

    1996-05-01

    Scanned electron beams are used within many industries for applications such as sterilization of medical disposables, crosslinking of wire and cables insulating jackets, polymerization and degradation of resins and biomaterials, modification of semiconductors, coloration of gemstones and glasses, removal of oxides from coal plant flue gasses, and the curing of advanced composites and other molded forms. X-rays generated from scanned electron beams make yet other applications, such as food irradiation, viable. Typical accelerators for these applications range in beam energy from 0.5MeV to 10 MeV, with beam powers between 5 to 500kW and scanning widths between 20 and 300 cm. Since precise control of dose delivery is required in many of these applications, the integration of beam characteristics, product conveyance, and beam scanning mechanisms must be well understood and optimized. Fundamental issues and some case examples are presented.

  19. Role of bone scan in rheumatic disease

    International Nuclear Information System (INIS)

    Choi, Yun Young

    2003-01-01

    Rheumatic diseases can be categorized by pathology into several specific types of musculoskeletal problems, including synovitis (e.g. rheumatoid arthritis), enthesopathy (e.g. ankylosing spondylitis) and cartilage degeneration (e.g. osteoarthritis). Skeletal radiographs have contributed to the diagnosis of these articular diseases, and some disease entities need typical radiographic changes as a factor of the diagnostic criteria. However, they sometimes show normal radiographic findings in the early stage of disease, when there is demineralization of less than 30-50%. Bone scans have also been used in arthritis, but not widely because the findings are nonspecific and it is thought that bone scans do not add significant information to routine radiography. Bone scans do however play a different role than simple radiography, and it is a complementary imaging method in the course of management of arthritis. The image quality of bone scans can be improved by obtaining regional views and images under al pin-hole collimator, and through a variety of scintigraphic techniques including the three phase bone scan and bone SPECT. Therefore, bone scans could improve the diagnostic value, and answer multiple clinical questions, based on the pathophysiology of various forms of arthritis

  20. Technetium 99mTc Pertechnetate Brain Scanning

    International Nuclear Information System (INIS)

    Rhee, Sang Min; Park, Jin Yung; Lee, Ahn Ki; Chung, Choo Il; Hong, Chang Gi; Rhee, Chong Heon; Koh, Chang Soon

    1968-01-01

    Technetium 99 mTc pertechnetate brain scanning were performed in 3 cases of head injury (2 chronic subdural hematomas and 1 acute epidural hematoma), 2 cases of brain abscess and 1 case of intracerebral hematoma associated with arteriovenous anomaly. In all the cases brain scintigrams showed 'hot areas.' Literatures on radioisotope scanning of intracranial lesions were briefly reviewed. With the improvement of radioisotope scanner and development of new radiopharmaceuticals brain scanning became a safe and useful screening test for diagnosis of intracranial lesions. Brain scanning can be easily performed even to a moribund patient without any discomfort and risk to the patient which are associated with cerebral angiography or pneumoencephalography. Brain scanning has been useful in diagnosis of brain tumor, brain abscess, subdural hematoma, and cerebral vascular diseases. In 80 to 90% of brain tumors positive scintigrams can be expected. Early studies were done with 203 Hg-Neohydrin or 131 I-serum albumin. With these agents, however, patients receive rather much radiation to the whole body and kidneys. In 1965 Harper introduced 99 mTc to reduce radiation dose to the patient and improve statistical variation in isotope scanning.

  1. Bone scans in nasopharyngeal carcinoma: local experience

    International Nuclear Information System (INIS)

    Tiong, S.

    2004-01-01

    Introduction: Nasopharyngeal carcinoma (NPC) tops the list of malignancy in Malaysia and ranks first in male malignancy in the state of Sarawak. The majority of the NPC patients presented in the advanced stages and often with distal metastasis usually to the bones. In our local hospital is the new practice of bone scan using Tc99 started last year. Over a period of 9 months from July 2003 to March 2004, 41 NPC patients had the bone scans and our experience in these are reviewed and presented. Method: The NPC patients are selected consecutively including both new and treated patients. The scanner used is Siemen E.cam plus and Technecium (Tc99) the radio-active isotope used. The scan images are read and reported by qualified and trained Radiologists. The bone scans are requested from the ENT Specialist of the ENT department of the Hospital. The bone scan reports are checked by the ENT Specialists and the decisions made as to clinical correlation and further definitive imaging studies. Results: 41 NPC patients were included in the studies, 29 newly diagnosed and bone-canned before treatment started and 12 treated of which 3 being diagnosed having recurrent NPC. Of the 29 newly diagnosed patients, one was found true positive bone scan having increased radio-tracer uptake and confirmed Xray imagings. 3 of the treated patients had true positive bone scan with increased radio-tracer uptake and confirmed Xray imagings. Hence a total of 4 out of the 41 patients (9.8%) had bone metastasis on positive bone scans. Of the 29 newly diagnosed patients, 14 were found false positive bone scan having increased radio-tracer uptake but no confirmed X ray imagings. 4 of the treated patients had false positive bone scan with increased radio-tracer uptake but no confirmed X ray imagings. Hence a total of 18 out of the 41 patients (44%) had no bone metastasis on positive bone scans. There were 6 patients with symptoms referable to the bones' distal to the head and 2 had true positive bone

  2. Diagnosis of Stomach Carcinoma by Radioisotope Scanning

    Energy Technology Data Exchange (ETDEWEB)

    Czerniak, P.; Meytes, E.; Sinkover, A.; Bank, H. [Tel-Hashomer Government Hospital, University of Tel Aviv School of Medicine (Israel)

    1969-05-15

    Scanning of the stomach after administration of {sup 131}I and {sup 99m}Tc is presented. Experiments on 20 dogs were performed and 105 patients were examined. The studies with {sup 131}I are only mentioned briefly as they have been summarized in a previous publication and we have concentrated on our experience with {sup 99m}Tc and on stomach carcinoma. The turnover of the nuclide in blood, urine, gastric juice and gastric mucosa was tested: in-vivo and post-operative scannings were performed. The scans are classified in four groups. Carcinoma of the stomach results in space-occupying lesions or foggy scans. A correlation of 85 - 90% between scan results and clinical findings is noted. A special group of 10 volunteers was examined to establish the possibility of a screening examination for the detection of stomach cancer using the technique presented. (author)

  3. Scanning tunneling microscope assembly, reactor, and system

    Science.gov (United States)

    Tao, Feng; Salmeron, Miquel; Somorjai, Gabor A

    2014-11-18

    An embodiment of a scanning tunneling microscope (STM) reactor includes a pressure vessel, an STM assembly, and three spring coupling objects. The pressure vessel includes a sealable port, an interior, and an exterior. An embodiment of an STM system includes a vacuum chamber, an STM reactor, and three springs. The three springs couple the STM reactor to the vacuum chamber and are operable to suspend the scanning tunneling microscope reactor within the interior of the vacuum chamber during operation of the STM reactor. An embodiment of an STM assembly includes a coarse displacement arrangement, a piezoelectric fine displacement scanning tube coupled to the coarse displacement arrangement, and a receiver. The piezoelectric fine displacement scanning tube is coupled to the coarse displacement arrangement. The receiver is coupled to the piezoelectric scanning tube and is operable to receive a tip holder, and the tip holder is operable to receive a tip.

  4. Significance of leukocyte scanning in infected endoprostheses

    Energy Technology Data Exchange (ETDEWEB)

    Becker, W.; Pasurka, B.; Boerner, W.

    1989-03-01

    31 patients with suspected septic loosening of an endoprosthesis (hip endoprosthesis n=30; knee endoprosthesis n=1) were examined with leukocyte scans (10 MBq /sup 111/In-oxine: n=22; 300 MBq /sup 99m/Tc-HMPAO: n=9). The results were compared with results of the bacterial growth (n=22), the histology (n=12) and of the bone scans (/sup 99m/Tc-MDP: n=20) which were performed within 4 days. The sensitivity of the bone scan was 100%, the specificity 30% and the diagnostic accuracy regarding a septic loosening of the arthroplasty was 55%. For the leukocyte scans a comparable sensitivity of 100%, but a higher specificity (86%) and accuracy (91%) could be calculated. A false positive leukocyte scan could be observed in a periprosthetic granuloma, an ossifying periarthritis and in a patient with negative bacterial growth with the histological proof of an inflammation.

  5. Assessing ScanSAR Interferometry for Deformation Studies

    Science.gov (United States)

    Buckley, S. M.; Gudipati, K.

    2007-12-01

    There is a trend in civil satellite SAR mission design to implement an imaging strategy that incorporates both stripmap mode and ScanSAR imaging. This represents a compromise between high resolution data collection and a desire for greater spatial coverage and more frequent revisit times. However, mixed mode imaging can greatly reduce the number of stripmap images available for measuring subtle ground deformation. Although ScanSAR-ScanSAR and ScanSAR-stripmap repeat-pass interferometry have been demonstrated, these approaches are infrequently used for single interferogram formation and nonexistent for InSAR time series analysis. For future mission design, e.g., a dedicated US InSAR mission, the effect of various ScanSAR system parameter choices on InSAR time series analysis also remains unexplored. Our objective is to determine the utility of ScanSAR differential interferometry. We will demonstrate the use of ScanSAR interferograms for several previous deformation studies: localized and broad-scale urban land subsidence, tunneling, volcanic surface movements and several examples associated with the seismic cycle. We also investigate the effect of various ScanSAR burst synchronization levels on our ability to detect and make quality measurements of deformation. To avoid the issues associated with Envisat ScanSAR burst alignment and to exploit a decade of InSAR measurements, we simulate ScanSAR data by bursting (throwing away range lines of) ERS-1/2 data. All the burst mode datasets are processed using a Modified SPECAN algorithm. To investigate the effects of burst misalignment, a number of cases with varying degrees of burst overlap are considered. In particular, we look at phase decorrelation as a function of percentage of burst overlap. Coherence clearly reduces as the percentage of overlap decreases and we find a useful threshold of 40-70% burst overlap depending on the study site. In order to get a more generalized understanding for different surface conditions

  6. StarScan: a web server for scanning small RNA targets from degradome sequencing data.

    Science.gov (United States)

    Liu, Shun; Li, Jun-Hao; Wu, Jie; Zhou, Ke-Ren; Zhou, Hui; Yang, Jian-Hua; Qu, Liang-Hu

    2015-07-01

    Endogenous small non-coding RNAs (sRNAs), including microRNAs, PIWI-interacting RNAs and small interfering RNAs, play important gene regulatory roles in animals and plants by pairing to the protein-coding and non-coding transcripts. However, computationally assigning these various sRNAs to their regulatory target genes remains technically challenging. Recently, a high-throughput degradome sequencing method was applied to identify biologically relevant sRNA cleavage sites. In this study, an integrated web-based tool, StarScan (sRNA target Scan), was developed for scanning sRNA targets using degradome sequencing data from 20 species. Given a sRNA sequence from plants or animals, our web server performs an ultrafast and exhaustive search for potential sRNA-target interactions in annotated and unannotated genomic regions. The interactions between small RNAs and target transcripts were further evaluated using a novel tool, alignScore. A novel tool, degradomeBinomTest, was developed to quantify the abundance of degradome fragments located at the 9-11th nucleotide from the sRNA 5' end. This is the first web server for discovering potential sRNA-mediated RNA cleavage events in plants and animals, which affords mechanistic insights into the regulatory roles of sRNAs. The StarScan web server is available at http://mirlab.sysu.edu.cn/starscan/. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  7. Getting a CAT Scan (For Kids)

    Medline Plus

    Full Text Available ... A) Staying Safe Videos for Educators Search English Español Getting a CAT Scan (Video) KidsHealth / For Kids / Getting a CAT Scan (Video) Print en español Obtención de una tomografía computada (video) CAT stands ...

  8. Getting a CAT Scan (For Kids)

    Medline Plus

    Full Text Available ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... Español Getting a CAT Scan (Video) KidsHealth / For Kids / Getting a CAT Scan (Video) Print en español ...

  9. Liver-lung scan in the diagnosis of right subphrenic abscess

    International Nuclear Information System (INIS)

    Middleton, H.M. III; Patton, D.D.; Hoyumpa, A.M. Jr.; Schenker, S.

    1976-01-01

    To assess the value of liver-lung scanning in the diagnosis of right subphrenic abscess, 148 scans were reviewed against corresponding charts. Of 91 scans with adequate clinical data, overall scanning error was 19.3 percent with 14 false positive and 3 false negative scans. Among 49 scans (of the initial group of 91 studies) with presence or absence of actual pathology proved by surgery and/or autopsy, there were 3 true positive, 12 false positive, 29 true negative, and 3 false negative scans. Analysis of data indicated lower accuracy of scan interpretation than generally reported, low specificity for positive scans and high specificity for negative scans, correlation of false interpretations with atypical degrees of liver-lung separation and with scanning defects in liver and lung, and failure of rereading significantly to improve accuracy of interpretation

  10. Development of scanning holographic display using MEMS SLM

    Science.gov (United States)

    Takaki, Yasuhiro

    2016-10-01

    Holography is an ideal three-dimensional (3D) display technique, because it produces 3D images that naturally satisfy human 3D perception including physiological and psychological factors. However, its electronic implementation is quite challenging because ultra-high resolution is required for display devices to provide sufficient screen size and viewing zone. We have developed holographic display techniques to enlarge the screen size and the viewing zone by use of microelectromechanical systems spatial light modulators (MEMS-SLMs). Because MEMS-SLMs can generate hologram patterns at a high frame rate, the time-multiplexing technique is utilized to virtually increase the resolution. Three kinds of scanning systems have been combined with MEMS-SLMs; the screen scanning system, the viewing-zone scanning system, and the 360-degree scanning system. The screen scanning system reduces the hologram size to enlarge the viewing zone and the reduced hologram patterns are scanned on the screen to increase the screen size: the color display system with a screen size of 6.2 in. and a viewing zone angle of 11° was demonstrated. The viewing-zone scanning system increases the screen size and the reduced viewing zone is scanned to enlarge the viewing zone: a screen size of 2.0 in. and a viewing zone angle of 40° were achieved. The two-channel system increased the screen size to 7.4 in. The 360-degree scanning increases the screen size and the reduced viewing zone is scanned circularly: the display system having a flat screen with a diameter of 100 mm was demonstrated, which generates 3D images viewed from any direction around the flat screen.

  11. Scanning-time evaluation of Digimarc Barcode

    Science.gov (United States)

    Gerlach, Rebecca; Pinard, Dan; Weaver, Matt; Alattar, Adnan

    2015-03-01

    This paper presents a speed comparison between the use of Digimarc® Barcodes and the Universal Product Code (UPC) for customer checkout at point of sale (POS). The recently introduced Digimarc Barcode promises to increase the speed of scanning packaged goods at POS. When this increase is exploited by workforce optimization systems, the retail industry could potentially save billions of dollars. The Digimarc Barcode is based on Digimarc's watermarking technology, and it is imperceptible, very robust, and does not require any special ink, material, or printing processes. Using an image-based scanner, a checker can quickly scan consumer packaged goods (CPG) embedded with the Digimarc Barcode without the need to reorient the packages with respect to the scanner. Faster scanning of packages saves money and enhances customer satisfaction. It reduces the length of the queues at checkout, reduces the cost of cashier labor, and makes self-checkout more convenient. This paper quantifies the increase in POS scanning rates resulting from the use of the Digimarc Barcode versus the traditional UPC. It explains the testing methodology, describes the experimental setup, and analyzes the obtained results. It concludes that the Digimarc Barcode increases number of items per minute (IPM) scanned at least 50% over traditional UPC.

  12. Automatic detection of axillary lymphadenopathy on CT scans of untreated chronic lymphocytic leukemia patients

    Science.gov (United States)

    Liu, Jiamin; Hua, Jeremy; Chellappa, Vivek; Petrick, Nicholas; Sahiner, Berkman; Farooqui, Mohammed; Marti, Gerald; Wiestner, Adrian; Summers, Ronald M.

    2012-03-01

    Patients with chronic lymphocytic leukemia (CLL) have an increased frequency of axillary lymphadenopathy. Pretreatment CT scans can be used to upstage patients at the time of presentation and post-treatment CT scans can reduce the number of complete responses. In the current clinical workflow, the detection and diagnosis of lymph nodes is usually performed manually by examining all slices of CT images, which can be time consuming and highly dependent on the observer's experience. A system for automatic lymph node detection and measurement is desired. We propose a computer aided detection (CAD) system for axillary lymph nodes on CT scans in CLL patients. The lung is first automatically segmented and the patient's body in lung region is extracted to set the search region for lymph nodes. Multi-scale Hessian based blob detection is then applied to detect potential lymph nodes within the search region. Next, the detected potential candidates are segmented by fast level set method. Finally, features are calculated from the segmented candidates and support vector machine (SVM) classification is utilized for false positive reduction. Two blobness features, Frangi's and Li's, are tested and their free-response receiver operating characteristic (FROC) curves are generated to assess system performance. We applied our detection system to 12 patients with 168 axillary lymph nodes measuring greater than 10 mm. All lymph nodes are manually labeled as ground truth. The system achieved sensitivities of 81% and 85% at 2 false positives per patient for Frangi's and Li's blobness, respectively.

  13. High rates of clinically relevant incidental findings by total-body CT scanning in trauma patients; results of the REACT-2 trial

    Energy Technology Data Exchange (ETDEWEB)

    Treskes, K.; Bos, S.A.; Sierink, J.C.; Luitse, J.S.K.; Goslings, J.C. [Academic Medical Center, Trauma Unit, Department of Surgery, Amsterdam (Netherlands); Beenen, L.F.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Edwards, M.J.R. [Radboud University Medical Center, Department of Trauma and emergency surgery, Nijmegen (Netherlands); Beuker, B.J.A. [University Medical Center Groningen, Trauma Unit, Department of Surgery, Groningen (Netherlands); Muradin, G.S.R. [University Medical Center Rotterdam, Department of Radiology, Erasmus MC, Rotterdam (Netherlands); Hohmann, J. [University of Basel Hospital, Department of Radiology and Nuclear Medicine, Basel (Switzerland); Hollmann, M.W. [Academic Medical Center, Department of Anaesthesiology, Amsterdam (Netherlands); Dijkgraaf, M.G.W. [Academic Medical Center, Clinical Research Unit, Amsterdam (Netherlands); Collaboration: REACT-2 study group

    2017-06-15

    To determine whether there is a difference in frequency and clinical relevance of incidental findings detected by total-body computed tomography scanning (TBCT) compared to those by the standard work-up (STWU) with selective computed tomography (CT) scanning. Trauma patients from five trauma centres were randomized between April 2011 and January 2014 to TBCT imaging or STWU consisting of conventional imaging with selective CT scanning. Incidental findings were divided into three categories: 1) major finding, may cause mortality; 2) moderate finding, may cause morbidity; and 3) minor finding, hardly relevant. Generalized estimating equations were applied to assess differences in incidental findings. In total, 1083 patients were enrolled, of which 541 patients (49.9 %) were randomized for TBCT and 542 patients (50.1 %) for STWU. Major findings were detected in 23 patients (4.3 %) in the TBCT group compared to 9 patients (1.7 %) in the STWU group (adjusted rate ratio 2.851; 95%CI 1.337-6.077; p < 0.007). Findings of moderate relevance were detected in 120 patients (22.2 %) in the TBCT group compared to 86 patients (15.9 %) in the STWU group (adjusted rate ratio 1.421; 95%CI 1.088-1.854; p < 0.010). Compared to selective CT scanning, more patients with clinically relevant incidental findings can be expected by TBCT scanning. (orig.)

  14. Scanning Quantum Cryogenic Atom Microscope

    Science.gov (United States)

    Yang, Fan; Kollár, Alicia J.; Taylor, Stephen F.; Turner, Richard W.; Lev, Benjamin L.

    2017-03-01

    Microscopic imaging of local magnetic fields provides a window into the organizing principles of complex and technologically relevant condensed-matter materials. However, a wide variety of intriguing strongly correlated and topologically nontrivial materials exhibit poorly understood phenomena outside the detection capability of state-of-the-art high-sensitivity high-resolution scanning probe magnetometers. We introduce a quantum-noise-limited scanning probe magnetometer that can operate from room-to-cryogenic temperatures with unprecedented dc-field sensitivity and micron-scale resolution. The Scanning Quantum Cryogenic Atom Microscope (SQCRAMscope) employs a magnetically levitated atomic Bose-Einstein condensate (BEC), thereby providing immunity to conductive and blackbody radiative heating. The SQCRAMscope has a field sensitivity of 1.4 nT per resolution-limited point (approximately 2 μ m ) or 6 nT /√{Hz } per point at its duty cycle. Compared to point-by-point sensors, the long length of the BEC provides a naturally parallel measurement, allowing one to measure nearly 100 points with an effective field sensitivity of 600 pT /√{Hz } for each point during the same time as a point-by-point scanner measures these points sequentially. Moreover, it has a noise floor of 300 pT and provides nearly 2 orders of magnitude improvement in magnetic flux sensitivity (down to 10-6 Φ0/√{Hz } ) over previous atomic probe magnetometers capable of scanning near samples. These capabilities are carefully benchmarked by imaging magnetic fields arising from microfabricated wire patterns in a system where samples may be scanned, cryogenically cooled, and easily exchanged. We anticipate the SQCRAMscope will provide charge-transport images at temperatures from room temperature to 4 K in unconventional superconductors and topologically nontrivial materials.

  15. The along track scanning radiometer for ERS-1 - Scan geometry and data simulation

    Science.gov (United States)

    Prata, A. J. Fred; Cechet, Robert P.; Barton, Ian J.; Llewellyn-Jones, David T.

    1990-01-01

    The first European remote-sensing satellite (ERS-1), due to be launched in 1990, will carry the along track scanning radiometer (ATSR), which has been specifically designed to give accurate satellite measurements of sea surface temperature (SST). Details of the novel scanning technique used by the ATSR are given, and data from the NOAA-9 AVHRR instrument are used to simulate raw ATSR imagery. Because of the high precision of the onboard blackbodies, the active cooling of the detectors, 12-b digitization, and dual-angle capability, the ATSR promises to achieve higher-accuracy satellite-derived SSTs than are currently available.

  16. Industrial site particulate pollution monitoring with an eye-safe and scanning industrial fiber lidar

    Science.gov (United States)

    Belanger, Brigitte; Fougeres, Andre; Talbot, Mario

    2001-02-01

    12 Over the past few years, INO has developed an Industrial Fiber Lidar (IFL). It enables the particulate pollution monitoring on industrial sites. More particularly, it has been used to take measurements of particulate concentration at Port Facilities of an aluminum plant during boat unloading. It is an eye-safe and portable lidar. It uses a fiber laser also developed at INO emitting 1.7 microJoules at 1534 nm with a pulse repetition frequency of 5 kHz. Given the harsh environment of an industrial site, all the sensitive equipment like the laser source, detector, computer and acquisition electronics are located in a building and connected to the optical module, placed outside, via optical fibers up to 500 m long. The fiber link also offers all the flexibility for placing the optical module at a proper location. The optical module is mounted on a two axis scanning platform, able to perform an azimuth scan of 0 to 355 deg and an elevation scan of +/- 90 deg, which enables the scanning of zones defined by the user. On this industrial site, materials like bauxite, alumina, spathfluor and calcined coke having mass extinction coefficients ranging from 0.53 to 2.7 m2/g can be detected. Data for different measurement configurations have been obtained. Concentration values have been calculated for measurements in a hopper, along a wharf and over the urban area close to the port facilities. The lidar measurements have been compared to high volume samplers. Based on these comparisons, it has been established that the IFL is able to monitor the relative fluctuations of dust concentrations. It can be integrated to the process control of the industrial site for alarm generation when concentrations are above threshold.

  17. Space Radar Image of West Texas - SAR scan

    Science.gov (United States)

    1999-01-01

    This radar image of the Midland/Odessa region of West Texas, demonstrates an experimental technique, called ScanSAR, that allows scientists to rapidly image large areas of the Earth's surface. The large image covers an area 245 kilometers by 225 kilometers (152 miles by 139 miles). It was obtained by the Spaceborne Imaging Radar-C/X-Band Synthetic Aperture Radar (SIR-C/X-SAR) flying aboard the space shuttle Endeavour on October 5, 1994. The smaller inset image is a standard SIR-C image showing a portion of the same area, 100 kilometers by 57 kilometers (62 miles by 35 miles) and was taken during the first flight of SIR-C on April 14, 1994. The bright spots on the right side of the image are the cities of Odessa (left) and Midland (right), Texas. The Pecos River runs from the top center to the bottom center of the image. Along the left side of the image are, from top to bottom, parts of the Guadalupe, Davis and Santiago Mountains. North is toward the upper right. Unlike conventional radar imaging, in which a radar continuously illuminates a single ground swath as the space shuttle passes over the terrain, a Scansar radar illuminates several adjacent ground swaths almost simultaneously, by 'scanning' the radar beam across a large area in a rapid sequence. The adjacent swaths, typically about 50 km (31 miles) wide, are then merged during ground processing to produce a single large scene. Illumination for this L-band scene is from the top of the image. The beams were scanned from the top of the scene to the bottom, as the shuttle flew from left to right. This scene was acquired in about 30 seconds. A normal SIR-C image is acquired in about 13 seconds. The ScanSAR mode will likely be used on future radar sensors to construct regional and possibly global radar images and topographic maps. The ScanSAR processor is being designed for 1996 implementation at NASA's Alaska SAR Facility, located at the University of Alaska Fairbanks, and will produce digital images from the

  18. A Student-Built Scanning Tunneling Microscope

    Science.gov (United States)

    Ekkens, Tom

    2015-01-01

    Many introductory and nanotechnology textbooks discuss the operation of various microscopes including atomic force (AFM), scanning tunneling (STM), and scanning electron microscopes (SEM). In a nanotechnology laboratory class, students frequently utilize microscopes to obtain data without a thought about the detailed operation of the tool itself.…

  19. Scanning Capacitance Microscopy | Materials Science | NREL

    Science.gov (United States)

    obtained using scanning capacitance microscopy. Top Right: Image of p-type and n-type material, obtained 'fingers' of light-colored n-type material on a yellow and blue background representing p-type material material, obtained using scanning capacitance microscopy, in a sample semiconductor device; the image shows

  20. Footwear scanning systems and methods

    Science.gov (United States)

    Fernandes, Justin L.; McMakin, Douglas L.; Sheen, David M.; Tedeschi, Jonathan R.

    2017-07-25

    Methods and apparatus for scanning articles, such as footwear, to provide information regarding the contents of the articles are described. According to one aspect, a footwear scanning system includes a platform configured to contact footwear to be scanned, an antenna array configured to transmit electromagnetic waves through the platform into the footwear and to receive electromagnetic waves from the footwear and the platform, a transceiver coupled with antennas of the antenna array and configured to apply electrical signals to at least one of the antennas to generate the transmitted electromagnetic waves and to receive electrical signals from at least another of the antennas corresponding to the electromagnetic waves received by the others of the antennas, and processing circuitry configured to process the received electrical signals from the transceiver to provide information regarding contents within the footwear.

  1. Influence of modulation frequency in rubidium cell frequency standards

    Science.gov (United States)

    Audoin, C.; Viennet, J.; Cyr, N.; Vanier, J.

    1983-01-01

    The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

  2. Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples.

    Science.gov (United States)

    Hong, Hyobong; Lim, Eul-Gyoon; Jeong, Jae-Chan; Chang, Jiho; Shin, Sung-Woong; Krause, Hans-Joachim

    2016-06-09

    The setup of a planar Frequency Mixing Magnetic Detection (p-FMMD) scanner for performing Magnetic Particles Imaging (MPI) of flat samples is presented. It consists of two magnetic measurement heads on both sides of the sample mounted on the legs of a u-shaped support. The sample is locally exposed to a magnetic excitation field consisting of two distinct frequencies, a stronger component at about 77 kHz and a weaker field at 61 Hz. The nonlinear magnetization characteristics of superparamagnetic particles give rise to the generation of intermodulation products. A selected sum-frequency component of the high and low frequency magnetic field incident on the magnetically nonlinear particles is recorded by a demodulation electronics. In contrast to a conventional MPI scanner, p-FMMD does not require the application of a strong magnetic field to the whole sample because mixing of the two frequencies occurs locally. Thus, the lateral dimensions of the sample are just limited by the scanning range and the supports. However, the sample height determines the spatial resolution. In the current setup it is limited to 2 mm. As examples, we present two 20 mm × 25 mm p-FMMD images acquired from samples with 1 µm diameter maghemite particles in silanol matrix and with 50 nm magnetite particles in aminosilane matrix. The results show that the novel MPI scanner can be applied for analysis of thin biological samples and for medical diagnostic purposes.

  3. MR guided spatial normalization of SPECT scans

    International Nuclear Information System (INIS)

    Crouch, B.; Barnden, L.R.; Kwiatek, R.

    2010-01-01

    Full text: In SPECT population studies where magnetic resonance (MR) scans are also available, the higher resolution of the MR scans allows for an improved spatial normalization of the SPECT scans. In this approach, the SPECT images are first coregistered to their corresponding MR images by a linear (affine) transformation which is calculated using SPM's mutual information maximization algorithm. Non-linear spatial normalization maps are then computed either directly from the MR scans using SPM's built in spatial normalization algorithm, or, from segmented TI MR images using DARTEL, an advanced diffeomorphism based spatial normalization algorithm. We compare these MR based methods to standard SPECT based spatial normalization for a population of 27 fibromyalgia patients and 25 healthy controls with spin echo T 1 scans. We identify significant perfusion deficits in prefrontal white matter in FM patients, with the DARTEL based spatial normalization procedure yielding stronger statistics than the standard SPECT based spatial normalization. (author)

  4. Laser scanning of experimental solar cells

    Science.gov (United States)

    Plunkett, B. C.; Lasswell, P. G.

    1980-01-01

    A description is presented of a laser scanning instrument which makes it possible to display and measure the spatial response of a solar cell. Examples are presented to illustrate the use of generated micrographs in the isolation of flaws and features of the cell. The laser scanner system uses a 4 mW, CW helium-neon laser, operating a wavelength of 0.633 micrometers. The beam is deflected by two mirror galvanometers arranged to scan in orthogonal directions. After being focused on the solar cell by the beam focusing lens, the moving light spot raster scans the specimen. The current output of the photovoltaic device under test, as a function of the scan dot position, can be displayed in several modes. The laser scanner has proved to be a very useful diagnostic tool in optimizing the process design of transparent metal film photovoltaic devices on Zn3P2, a relatively new photovoltaic material.

  5. Operation of a scanning near field optical microscope in reflection in combination with a scanning force microscope

    NARCIS (Netherlands)

    van Hulst, N.F.; Moers, M.H.P.; Moers, M.H.P.; Noordman, O.F.J.; Noordman, O.F.J.; Faulkner, T.; Segerink, Franciscus B.; van der Werf, Kees; de Grooth, B.G.; Bölger, B.; Bölger, B.

    1992-01-01

    Images obtained with a scanning near field optical microscope (SNOM) operating in reflection are presented. We have obtained the first results with a SiN tip as optical probe. The instrument is simultaneously operated as a scanning force microscope (SFM). Moreover, the instrument incorporates an

  6. Physics of the Brain. Prevention of the Epileptic Seizures by the Multi-photon Pulsed-operated Fiber Lasers in the Ultraviolet Range of Frequencies.

    Science.gov (United States)

    Stefan, V. Alexander; IAPS Team

    The novel study of the epileptogenesis mechanisms is proposed. It is based on the pulsed-operated (amplitude modulation) multi-photon (frequency modulation) fiber-laser interaction with the brain epilepsy-topion (the epilepsy onset area), so as to prevent the excessive electrical discharge (epileptic seizure) in the brain. The repetition frequency, Ω, matches the low frequency (epileptic) phonon waves in the brain. The laser repetition frequency (5-100 pulses per second) enables the resonance-scanning of the wide range of the phonon (possible epileptic-to-be) activity in the brain. The tunable fiber laser frequencies, Δω (multi photon operation), are in the ultraviolet frequency range, thus enabling monitoring of the electrical charge imbalance (within the 10s of milliseconds), and the DNA-corruption in the epilepsy-topion, as the possible cause of the disease. Supported by Nikola Tesla Labs., Stefan University.

  7. Frequency of osteopenia and associated risk factors among young female students

    International Nuclear Information System (INIS)

    Soomro, R.R.; Ahmed, S.I.; Khan, M.

    2017-01-01

    To find out the frequency of osteopenia and associated risk factors among young female students. Methods: This observational, cross-sectional study was conducted at the Dow University of Health Sciences, Karachi, from August 2011 to January 2012, and comprised young female students. Convenient sampling method was used. Age, residence, sun exposure, menstrual status, level of physical activity, exercise, vitamin D, calcium intake were variables of interest. Dual-energy X-ray absorptiometry scan was used to measure bone mineral density on the lumbar spine, hip, femur and distal forearm. SPSS 16 was used for data analysis. Results: A total of 100(76.9%) students were included in this study. The age range was 20-30 years. Overall,70(70%)participants were osteopenic, while 30(30%) were normal. Age<25 years, living with less exposure to sun, less physical activity and diet low in calcium and vitamin D were common risk factors. Conclusion: The frequency of osteopenia was significantly high among young female students. (author)

  8. Scanning probe recognition microscopy investigation of tissue scaffold properties

    Science.gov (United States)

    Fan, Yuan; Chen, Qian; Ayres, Virginia M; Baczewski, Andrew D; Udpa, Lalita; Kumar, Shiva

    2007-01-01

    Scanning probe recognition microscopy is a new scanning probe microscopy technique which enables selective scanning along individual nanofibers within a tissue scaffold. Statistically significant data for multiple properties can be collected by repetitively fine-scanning an identical region of interest. The results of a scanning probe recognition microscopy investigation of the surface roughness and elasticity of a series of tissue scaffolds are presented. Deconvolution and statistical methods were developed and used for data accuracy along curved nanofiber surfaces. Nanofiber features were also independently analyzed using transmission electron microscopy, with results that supported the scanning probe recognition microscopy-based analysis. PMID:18203431

  9. Scanning unit for collectrons

    International Nuclear Information System (INIS)

    Plaige, Yves.

    1976-01-01

    This invention concerns a measurement scanning assembly for collectron type detectors. It is used in measuring the neutron flux in nuclear reactors. As the number of these detectors in a reactor can be very great, they are not usually all connected permanently to the measuring facility but rather in turn by means of a scanning device which carries out, as it were, multiplexing between all the collectrons and the input of a single measuring system. The object of the invention is a scanning assembly which is of relative simplicity through an original organisation. Specifically, according to this organisation, the collectrons outputs are grouped together in bunches, each of these bunches being processed by a multiplexing sub-assembly belonging to a first stage, the different outputs of these multiplexing subassemblies of this first stage being grouped together yet again in bunches processed by multiplexors forming a new stage and so forth. Further, this structure is specially adapted for use with collectrons by utilising a current amplifier at each multiplexing level so that from one end to the other of the multiplexing system, the commutations are carried out on currents and not on voltages [fr

  10. Spatial scan statistics using elliptic windows

    DEFF Research Database (Denmark)

    Christiansen, Lasse Engbo; Andersen, Jens Strodl; Wegener, Henrik Caspar

    The spatial scan statistic is widely used to search for clusters in epidemiologic data. This paper shows that the usually applied elimination of secondary clusters as implemented in SatScan is sensitive to smooth changes in the shape of the clusters. We present an algorithm for generation of set...

  11. The low-frequency encoding disadvantage: Word frequency affects processing demands.

    Science.gov (United States)

    Diana, Rachel A; Reder, Lynne M

    2006-07-01

    Low-frequency words produce more hits and fewer false alarms than high-frequency words in a recognition task. The low-frequency hit rate advantage has sometimes been attributed to processes that operate during the recognition test (e.g., L. M. Reder et al., 2000). When tasks other than recognition, such as recall, cued recall, or associative recognition, are used, the effects seem to contradict a low-frequency advantage in memory. Four experiments are presented to support the claim that in addition to the advantage of low-frequency words at retrieval, there is a low-frequency disadvantage during encoding. That is, low-frequency words require more processing resources to be encoded episodically than high-frequency words. Under encoding conditions in which processing resources are limited, low-frequency words show a larger decrement in recognition than high-frequency words. Also, studying items (pictures and words of varying frequencies) along with low-frequency words reduces performance for those stimuli. Copyright 2006 APA, all rights reserved.

  12. Calibration of scanning Lidar

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Courtney, Michael

    This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast. Additio......This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast...

  13. Data acquisition and control for gamma scanning

    International Nuclear Information System (INIS)

    Barnes, B.K.; Murray, A.S.; Quintana, J.N.

    1980-01-01

    A new computer-based data acquisition and control unit has been installed in the Los Alamos Scientific Laboratory (LASL) system for scanning irradiated reactor fuel pins. The scanning mechanism is controlled by a commercial multichannel analyzer via a CAMAC link with an intelligent crate controller. The scanning and control unit consists of three linked LSI-11 computers. The multitasking capability of the commercial operation system allows control decisions to be based upon currently acquiring data

  14. The use of radionuclides in brain scan

    International Nuclear Information System (INIS)

    Boasquevisque, E.M.

    1979-01-01

    Brain scanning is easy to perform, safe and well tolerated by the patient. It has a high sensitivity, and accuracy (85-90%) in detecting focal lesions with a minimal size of 1.5-2cm, located superior to the brain stem; however, it lacks specificity. It does not compete with other procedures such as CT scan and angiography bit they rather complement one another. The brain scan is useful as a screening exam. (Author) [pt

  15. Exact cone beam CT with a spiral scan

    International Nuclear Information System (INIS)

    Tam, K.C.; Samarasekera, S.; Sauer, F.

    1998-01-01

    A method is developed which makes it possible to scan and reconstruct an object with cone beam x-rays in a spiral scan path with area detectors much shorter than the length of the object. The method is mathematically exact. If only a region of interest of the object is to be imaged, a top circle scan at the top level of the region of interest and a bottom circle scan at the bottom level of the region of interest are added. The height of the detector is required to cover only the distance between adjacent turns in the spiral projected at the detector. To reconstruct the object, the Radon transform for each plane intersecting the object is computed from the totality of the cone beam data. This is achieved by suitably combining the cone beam data taken at different source positions on the scan path; the angular range of the cone beam data required at each source position can be determined easily with a mask which is the spiral scan path projected on the detector from the current source position. The spiral scan algorithm has been successfully validated with simulated cone beam data. (author)

  16. Spatial scan statistics using elliptic windows

    DEFF Research Database (Denmark)

    Christiansen, Lasse Engbo; Andersen, Jens Strodl; Wegener, Henrik Caspar

    2006-01-01

    The spatial scan statistic is widely used to search for clusters. This article shows that the usually applied elimination of secondary clusters as implemented in SatScan is sensitive to smooth changes in the shape of the clusters. We present an algorithm for generation of a set of confocal elliptic...

  17. A Scanning Microwave Radar and Radiometer

    DEFF Research Database (Denmark)

    Skou, Niels

    1995-01-01

    The Scanning Microwave Radar and Radiometer (SMRR) is a line scanner featuring a combined radar and radiometer system operating around 35 and 94 GHz. The layout of the SMRR is shown. The 2 offset antenna parabolas scan in synchronism, the receiver antenna has the highest gain in order to ensure...

  18. Scanning electron microscope

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The principle underlying the design of the scanning electron microscope (SEM), the design and functioning of SEM are described. Its applications in the areas of microcircuitry and materials science are outlined. The development of SEM in India is reviewed. (M.G.B.)

  19. Scanning tunnelling microscope light emission: Finite temperature current noise and over cut-off emission.

    Science.gov (United States)

    Kalathingal, Vijith; Dawson, Paul; Mitra, J

    2017-06-14

    The spectral distribution of light emitted from a scanning tunnelling microscope junction not only bears its intrinsic plasmonic signature but is also imprinted with the characteristics of optical frequency fluc- tuations of the tunnel current. Experimental spectra from gold-gold tunnel junctions are presented that show a strong bias (V b ) dependence, curiously with emission at energies higher than the quantum cut-off (eV b ); a component that decays monotonically with increasing bias. The spectral evolution is explained by developing a theoretical model for the power spectral density of tunnel current fluctuations, incorporating finite temperature contribution through consideration of the quantum transport in the system. Notably, the observed decay of the over cut-off emission is found to be critically associated with, and well explained in terms of the variation in junction conductance with V b . The investigation highlights the scope of plasmon-mediated light emission as a unique probe of high frequency fluctuations in electronic systems that are fundamental to the electrical generation and control of plasmons.

  20. Scanning probe microscopy competency development

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, M.E.; Reagor, D.W.; Jia, Quan Xi [and others

    1998-12-31

    This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The project collaborators developed an ultra-high vacuum scanning tunneling microscope (UHV-STM) capability, integrated it with existing scanning probe microscopes, and developed new, advanced air-based scanning force techniques (SPMs). Programmatic, basic, and industrially related laboratory research requires the existence of SPMs, as well as expertise capable of providing local nano-scale information. The UHV-STM capability, equipped with load-lock system and several surface science techniques, will allow introduction, examination, and reaction of surfaces prepared under well-controlled vacuum conditions, including the examination of morphology and local bonding associated with the initial stages of film growth under controlled growth conditions. The resulting capabilities will enable the authors to respond to a variety of problems requiring local characterization of conducting and nonconducting surfaces in liquids, air, and UHV.