WorldWideScience

Sample records for fractures gliding screw-plating

  1. Dorsal bridge plating or transarticular screws for Lisfranc fracture dislocations.

    Science.gov (United States)

    Kirzner, N; Zotov, P; Goldbloom, D; Curry, H; Bedi, H

    2018-04-01

    Aims The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations. Patients and Methods A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction. Results Significantly better functional outcomes were seen in the bridge plate group. These patients had a mean AOFAS score of 82.5 points, compared with 71.0 for the screw group and 63.3 for the combination group (p bridge plate group, 38.1 in the screw group, and 45.5 in the combination group (p bridge plating have better functional and radiological outcomes than those treated with transarticular screws or a combination technique. Cite this article: Bone Joint J 2018;100-B:468-74.

  2. The mechanical benefit of medial support screws in locking plating of proximal humerus fractures.

    Directory of Open Access Journals (Sweden)

    Wen Zhang

    Full Text Available BACKGROUND: The purpose of this study was to evaluate the biomechanical advantages of medial support screws (MSSs in the locking proximal humeral plate for treating proximal humerus fractures. METHODS: Thirty synthetic left humeri were randomly divided into 3 subgroups to establish two-part surgical neck fracture models of proximal humerus. All fractures were fixed with a locking proximal humerus plate. Group A was fixed with medial cortical support and no MSSs; Group B was fixed with 3 MSSs but without medial cortical support; Group C was fixed with neither medial cortical support nor MSSs. Axial compression, torsional stiffness, shear stiffness, and failure tests were performed. RESULTS: Constructs with medial support from cortical bone showed statistically higher axial and shear stiffness than other subgroups examined (P<0.0001. When the proximal humerus was not supported by medial cortical bone, locking plating with medial support screws exhibited higher axial and torsional stiffness than locking plating without medial support screws (P ≤ 0.0207. Specimens with medial cortical bone failed primarily by fracture of the humeral shaft or humeral head. Specimens without medial cortical bone support failed primarily by significant plate bending at the fracture site followed by humeral head collapse or humeral head fracture. CONCLUSIONS: Anatomic reduction with medial cortical support was the stiffest construct after a simulated two-part fracture. Significant biomechanical benefits of MSSs in locking plating of proximal humerus fractures were identified. The reconstruction of the medial column support for proximal humerus fractures helps to enhance mechanical stability of the humeral head and prevent implant failure.

  3. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.

    Science.gov (United States)

    Röderer, Götz; Scola, Alexander; Schmölz, Werner; Gebhard, Florian; Windolf, Markus; Hofmann-Fliri, Ladina

    2013-10-01

    Proximal humerus fracture fixation can be difficult because of osteoporosis making it difficult to achieve stable implant anchorage in the weak bone stock even when using locking plates. This may cause implant failure requiring revision surgery. Cement augmentation has, in principle, been shown to improve stability. The aim of this study was to investigate whether augmentation of particular screws of a locking plate aimed at a region of low bone quality is effective in improving stability in a proximal humerus fracture model. Twelve paired human humerus specimens were included. Quantitative computed tomography was performed to determine bone mineral density (BMD). Local bone quality in the direction of the six proximal screws of a standard locking plate (PHILOS, Synthes) was assessed using mechanical means (DensiProbe™). A three-part fracture model with a metaphyseal defect was simulated and fixed with the plate. Within each pair of humeri the two screws aimed at the region of the lowest bone quality according to the DensiProbe™ were augmented in a randomised manner. For augmentation, 0.5 ml of bone cement was injected in a screw with multiple outlets at its tip under fluoroscopic control. A cyclic varus-bending test with increasing upper load magnitude was performed until failure of the screw-bone fixation. The augmented group withstood significantly more load cycles. The correlation of BMD with load cycles until failure and BMD with paired difference in load cycles to failure showed that augmentation could compensate for a low BMD. The results demonstrate that augmentation of screws in locked plating in a proximal humerus fracture model is effective in improving primary stability in a cyclic varus-bending test. The augmentation of two particular screws aimed at a region of low bone quality within the humeral head was almost as effective as four screws with twice the amount of bone cement. Screw augmentation combined with a knowledge of the local bone quality

  4. Dual small fragment plating improves screw-to-screw load sharing for mid-diaphyseal humeral fracture fixation: a finite element study.

    Science.gov (United States)

    Kosmopoulos, Victor; Luedke, Colten; Nana, Arvind D

    2015-01-01

    A smaller humerus in some patients makes the use of a large fragment fixation plate difficult. Dual small fragment plate constructs have been suggested as an alternative. This study compares the biomechanical performance of three single and one dual plate construct for mid-diaphyseal humeral fracture fixation. Five humeral shaft finite element models (1 intact and 4 fixation) were loaded in torsion, compression, posterior-anterior (PA) bending, and lateral-medial (LM) bending. A comminuted fracture was simulated by a 1-cm gap. Fracture fixation was modelled by: (A) 4.5-mm 9-hole large fragment plate (wide), (B) 4.5-mm 9-hole large fragment plate (narrow), (C) 3.5-mm 9-hole small fragment plate, and (D) one 3.5-mm 9-hole small fragment plate and one 3.5-mm 7-hole small fragment plate. Model A showed the best outcomes in torsion and PA bending, whereas Model D outperformed the others in compression and LM bending. Stress concentrations were located near and around the unused screw holes for each of the single plate models and at the neck of the screws just below the plates for all the models studied. Other than in PA bending, Model D showed the best overall screw-to-screw load sharing characteristics. The results support using a dual small fragment locking plate construct as an alternative in cases where crutch weight-bearing (compression) tolerance may be important and where anatomy limits the size of the humerus bone segment available for large fragment plate fixation.

  5. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    Science.gov (United States)

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  6. Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur

    OpenAIRE

    Shyam Kumar, A. J.; Parmar, V.; Bankart, J.; Williams, S. C.; Harper, W. M.

    2006-01-01

    This study compared the accuracy of lag screw placement between extracapsular femoral fractures fixed with sliding hip screw plate systems and those fixed with cephalocondylic nails. It involved 75 retrospective radiographs of fractures fixed with either a cephalocondylic nail (32) or a sliding hip screw plate system (43). Postoperative anteroposterior and lateral radiographs of the hip were scanned using a digital X-ray scanner and measured using computer software. Measurements were conducte...

  7. Perioperative lateral trochanteric wall fractures: sliding hip screw versus percutaneous compression plate for intertrochanteric hip fractures.

    Science.gov (United States)

    Langford, Joshua; Pillai, Gita; Ugliailoro, Anthony D; Yang, Edward

    2011-04-01

    This study was performed to determine the incidence of perioperative lateral wall fractures with a standard sliding hip screw (SHS) versus a percutaneous compression plate (PCCP) using identical meticulous closed reduction techniques in both groups. Retrospective analysis of a prospective trauma registry. Urban Level I trauma center. Over a 7-year period, 337 patients with intertrochanteric hip fractures were treated with either a SHS or a PCCP at our institution. The PCCP group (Group 1) consisted of 200 patients, of which 141 (71%) had adequate images to be included in the study. The SHS group (Group 2) consisted of 137 patients, of which 100 (73%) had adequate images to be included in the study. Closed reduction and plate application with either a standard sliding hip screw or a percutaneous compression plate for an Orthopaedic Trauma Association 31A1 or 31A2 intertrochanteric hip fracture. : Radiographic evidence of lateral trochanteric wall fracture as measured by intraoperative and perioperative radiographs. There was an overall lateral wall fracture incidence of 20% in the SHS group versus 1.4% in the PCCP group (P fracture types, there was a lateral wall fracture incidence of 29.8% in the SHS group versus 1.9% in the PCCP group (P trochanteric wall fracture compared with the SHS group. This difference became greater when just unstable intertrochanteric fractures were analyzed. An anatomic reduction, combined with a device (PCCP) that uses small-diameter defects in the lateral trochanteric wall, essentially eliminates perioperative lateral trochanteric wall fractures.

  8. Use of tranexamic acid in dynamic hip screw plate fixation for trochanteric fractures.

    Science.gov (United States)

    Baruah, Ranjit Kumar; Borah, Pranab Jyoti; Haque, Russel

    2016-12-01

    To evaluate perioperative blood loss and blood transfusion requirement in patients who underwent dynamic hip screw plate fixation for a stable trochanteric fracture with or without preoperative intravenous tranexamic acid (TXA). 49 men and 11 women (mean age, 56.5 years) who underwent open reduction and internal fixation with a dynamic hip screw plate for a stable trochanteric fracture by a single surgeon were equally randomised to receive either a single dose of intravenous TXA (15 mg/kg) 15 minutes prior to surgery or an equal volume of normal saline by slow infusion. Intra- and post-operative blood loss and the need for blood transfusion were assessed, as was any thromboembolic adverse event. The TXA and control groups were comparable in terms of age, gender, body mass index, blood pressure, pulse rate, time from injury to surgery, operating time, and preoperative haematological data. Blood loss was lower in the TXA than control group intraoperatively (320.3 vs. 403.33 ml, ptrochanteric fractures.

  9. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

    Science.gov (United States)

    Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola

    2017-08-24

    In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The

  10. Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates.

    Science.gov (United States)

    Hak, David J; Fader, Ryan; Baldini, Todd; Chadayammuri, Vivek B S

    2017-09-01

    Carbon-fibre reinforced polyetheretherketone (CFR-PEEK) plates have recently been introduced for proximal humerus fracture treatment. The purpose of this study was to compare the locking screw-plate interface stability in CFR-PEEK versus stainless steel (SS) proximal humerus plates. Locking screw mechanical stability was evaluated independently in proximal and shaft plate holes. Stiffness and load to failure were tested for three conditions: (1) on-axis locking screw insertion in CFR-PEEK versus SS plates, (2) on-axis locking screw insertion, removal, and reinsertion in CFR-PEEK plates, and (3) 10-degree off-axis locking screw insertion in CFR-PEEK plates. Cantilever bending at a rate of 1 mm/minute was produced by an Instron machine and load-displacement data recorded. Shaft locking screw load to failure was significantly greater in CFR-PEEK plates compared to SS plates (746.4 ± 89.7 N versus 596.5 ± 32.6 N, p PEEK plates (p PEEK plates. The mechanical stability of locking screws in CFR-PEEK plates is comparable or superior to locking screws in SS plates.

  11. Dynamic plate osteosynthesis for fracture stabilization: how to do it

    Directory of Open Access Journals (Sweden)

    Juerg Sonderegger

    2010-01-01

    Full Text Available Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent tibial and femoral fractures with not fully closed growth plates. Although many lower limb shaft fractures are managed successfully with intramedullary nails, there are some important advantages of open-reduction-and-plate fixation: the risk of malalignment, anterior knee pain, or nonunion seems to be lower. The surgeon performing a plate osteosynthesis has the possibility to influence fixation strength and micromotion at the fracture gap. Long plates and oblique screws at the plate ends increase fixation strength. However, the number of screws does influence stiffness and stability. Lag screws and screws close to the fracture site reduce micromotion dramatically. Dynamic plate osteosynthesis can be achieved by applying some simple rules: long plates with only a few screws should be used. Oblique screws at the plate ends increase the pullout strength. Two or three holes at the fracture site should be omitted. Lag screws, especially through the plate, must be avoided whenever possible. Compression is not required. Locking plates are recommended only in fractures close to the joint. When respecting these basic concepts, dynamic plate osteosynthesis is a safe procedure with a high healing and a low complication rate. 

  12. [Comparison of clinical effect on locking plate for proximal humeral fracture with or without application of inferomedial screws].

    Science.gov (United States)

    Guo, Xiu-wu; Fan, Jian; Yuan, Feng

    2016-06-01

    To compare clinical outcomes of locking plate for proximal humeral fracture whether application of inferomedial screws. From January 2012 to July 2013, 46 patients with proximal humeral fracture underwent locking plates were retrospectively analyzed. There were 25 males and 21 females aged from 29 to 80 years old with an average of 55.1 years old. Among them, 25 patients were treated with inferomedial screws (support group), including 13 males and 12 females aged from 38 to 80 years old with an average of (55.8 ± 11.8) years old; 8 cases were part two fracture,10 cases were part three fracture and 7 cases were part four fracture according to Neer classification. Twenty-one patients were treated without inferomedial screws (non-support group), including 12 males and 9 females aged from 29 to 79 years old with an average of (54.2 ± 14.8)years old; 6 cases were part two fracture, 9 cases were part three fracture and 6 cases were part four fracture according to Neer classification. Operative time, fracture healing time and complications were observed and compared, Neer scoring of shoulder joint were used to evaluate clinical effect. All patients were followed up from 12 to 41 months with an average of 15.6 months. Operative time and fracture healing time in support group was (1.6 ± 0.4) h and (3.0 ± 0.6) months, and (1.5 ± 0.4) h and (3.1 ± 0.6) months in non-support group, while there was no statistical difference in operative time and fracture healing time between two groups. There was significant differences in Neer score between support group (89.7± 4.9) and non-support group (83.1 ± 7.1). No complication occurred in support group,while 4 cases occurred complications in non-support group. Locking plate with inferomedial screws for proximal humeral fracture has advantages of stable fixation, less complications, quick recovery of function and satisfied clinical effect.

  13. Unconventional fixation Thoracolumbar fractures using round hole boneplates and transpedicular screws

    International Nuclear Information System (INIS)

    Behairy, Yaser M.

    2001-01-01

    In an attempt to contain the high cost of commercially available pediclescrew systems, several authors have used unconventional alternatives such aslocally made plates or dynamic compression plates (DCP) along with cancellousscrews for transpedicular fixation of the thoracolumbar spine. These plates,however, allow for a wide range of motion at the plate-screw interphase andthe construct does not provide stability in the sagittal plane. Round holebone plates, on the other hand, allow much less mobility at the plate-screwinterphase and the final construct offers better stability in the sagittalplane. Our objective was to determine the clinical, radiologic and functionalstatus of patients who underwent posterior fracture fixation using round holebone plates and cancellous screws and evaluate the construct's ability tomaintain reduction of the fracture. This was a postoperative follow-up ofpatients with fractures around the thoracolumbar junction fixed using roundhole bone plates and cancellous transpedicular screws. Round hole bone platesalong with 6.5 mm transpedicular cancellous screws were used for posteriorspinal instrumentation in neurologically intact patients with isolatedunstable fractures of the last thoracic or first lumbar vertebra. Seventeenpatients were included in this study. There mean follow-up was 10 months(range 5 to 12). All had evidence of fusion at a mean of 5 months (range 4 to7). No patients had breakage or loosening of the screws and none had breakageof the plate. The mean kyphosis angle at the fracture site was 34 degreepreoperatively, -4 degree in the immediate postoperative period, and 3 degreeon final follow-up radiographs. The percentage loss of anterior vertebralbody height was 51% in the immediate postoperative period and 16% on finalfollow-up radiographs. The use of round hole bone plates along with 6.5 mmcancellous screws inserted into the pedicles provides an angle-stableconstruct that allows for better stability in the sagittal plane

  14. The glide of screw dislocations in bcc Fe: Atomistic static and dynamic simulations

    International Nuclear Information System (INIS)

    Chaussidon, Julien; Fivel, Marc; Rodney, David

    2006-01-01

    We present atomic-scale simulations of screw dislocation glide in bcc iron. Using two interatomic potentials that, respectively, predict degenerate and non-degenerate core structures, we compute the static 0 K dependence of the screw dislocation Peierls stress on crystal orientation and show strong boundary condition effects related to the generation of non-glide stress components. At finite temperatures we show that, with a non-degenerate core, glide by nucleation/propagation of kink-pairs in a {1 1 0} glide plane is obtained at low temperatures. A transition in the twinning region, towards an average {1 1 2} glide plane, with the formation of debris loops is observed at higher temperatures

  15. Role of Appositional Screw Fixation in Minimally Invasive Plate Osteosynthesis for Distal Tibial Fracture.

    Science.gov (United States)

    Yang, Kyu-Hyun; Won, Yougun; Kang, Dong-Hyun; Oh, Jin-Cheol; Kim, Sung-Jun

    2015-09-01

    To determine the effect of interfragmentary appositional (gap-closing) screw fixation in minimally invasive plate osteosynthesis (MIPO) for distal tibial fractures on the clinical and radiologic results. Prospective nonrandomized study. Level I trauma center. Sixty patients who were diagnosed as distal metadiaphyseal oblique or spiral tibial fracture without displaced articular fragment. Thirty patients (group A) of the 60 patients were treated with MIPO without appositional screw fixation, and the other 30 (group B) were treated with the screw. Radiologic union, clinical union, clinical functional score [American Orthopaedic Foot and Ankle Society (AOFAS) score], and complications. The time for initial callus formation and radiologic union was significantly longer in group A than those in group B (76.8 vs. 58.0 days, P = 0.044; 409 vs. 258.7 days, P = 0.002, respectively). The rate of clinical union during 1 year was significantly higher in group B than in group A (P = 0.0063). Four nonunion patients in group A achieved bone union after placement of an additional bone graft. None of the patients in group B diagnosed with delayed union or nonunion (P fracture promoted callus formation and union rate compared with MIPO without appositional screw fixation. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  16. Fracture healing using degradable magnesium fixation plates and screws.

    Science.gov (United States)

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles

    2015-02-01

    Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Arthroscopy-assisted reduction of posteromedial tibial plateau fractures with buttress plate and cannulated screw construct.

    Science.gov (United States)

    Chiu, Chih-Hao; Cheng, Chun-Ying; Tsai, Min-Chain; Chang, Shih-Sheng; Chen, Alvin Chao-Yu; Chen, Yeung-Jen; Chan, Yi-Sheng

    2013-08-01

    To present the radiologic and clinical results of posteromedial fractures treated with arthroscopy-assisted reduction and buttress plate and cannulated screw fixation. Twenty-five patients with posteromedial tibial plateau fractures treated by the described technique were included in this study. According to the Schatzker classification, there were 5 type IV fractures (20%), 2 type V fractures (8%), and 18 type VI fractures (72%). The mean age at operation was 46 years (range, 21 to 79 years). The mean follow-up period was 86 months (range, 60 to 108 months). Clinical and radiologic outcomes were scored by the Rasmussen system. Subjective data were collected to assess swelling, difficulty climbing stairs, joint stability, ability to work and participate in sports, and overall patient satisfaction with recovery. Secondary osteoarthritis was diagnosed when radiographs showed a narrowed joint space in the injured knee at follow-up in comparison with the films taken at the time of injury. The mean postoperative Rasmussen clinical score was 25.9 (range, 18 to 29), and the mean radiologic score was 15.8 (range, 10 to 18). All 25 fractures achieved successful union, and 92% had good or excellent clinical and radiologic results. The 3 fracture types did not significantly differ in Rasmussen scores or rates of satisfactory results (P > .05). Secondary osteoarthritis was noted in 6 injured knees (24%). Arthroscopy-assisted reduction with buttress plate and cannulated screw fixation can restore posteromedial tibial plateau fractures of the knee with well-documented radiographic healing, good clinical outcomes, and low complication rates. Level IV, therapeutic case series. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Unstable metacarpal and phalangeal fractures: treatment by internal fixation using AO mini-fragment plates and screws.

    Science.gov (United States)

    Mumtaz, Mohammad Umar; Farooq, Muneer Ahmad; Rasool, Altaf Ahmad; Kawoosa, Altaf Ahmad; Badoo, Abdul Rashid; Dhar, Shabir Ahmad

    2010-07-01

    Accurate open reduction and internal fixation for metacarpal and phalangeal fractures of the hand is required in less than 5% of the patients; otherwise, closed treatment techniques offer satisfactory results in most of these cases as these fractures are stable either before or after closed reduction. AO mini-fragment screws and plates, when used in properly selected cases, can provide rigid fixation, allowing early mobilization of joints and hence good functional results while avoiding problems associated with protruding K-wires and immobilization. The advantages of such internal fixation urged us to undertake such a study in our state where such hand injuries are commonly seen. Forty patients with 42 unstable metacarpal and phalangeal fractures were treated with open reduction and internal fixation using AO mini-fragment screws and plates over a period of three years in a prospective manner. The overall results were good in 78.5% of cases, fair in 19% of cases and poor in 2.5% of cases, as judged according to the criteria of the American Society for Surgery of the Hand. This technique is a reasonable option for treating unstable metacarpal and phalangeal fractures as it provides a highly rigid fixation, which is sufficient to allow early mobilization of the adjacent joints, thus helping to achieve good functional results.

  19. Sacroiliac screw fixation for tile B fractures.

    NARCIS (Netherlands)

    Bosch, E.W. van den; Zwienen, C.M. van; Hoek van Dijke, G.A.; Snijders, C.J.; Vugt, A.B. van

    2003-01-01

    BACKGROUND: The purpose of this comparative cadaveric study was to investigate whether the stability of partially unstable pelvic fractures can be improved by combining plate fixation of the symphysis with a posterior sacroiliac screw. METHODS: In six specimens, a Tile B1 (open-book) pelvic fracture

  20. [Efficacy of Sacroiliac Joint Anterior Approach with Double Reconstruction Plate and Computer Assisted Navigation Percutaneous Sacroiliac Screw for Treating Tile C1 Pelvic Fractures].

    Science.gov (United States)

    Tan, Zhen; Fang, Yue; Zhang, Hui; Liu, Lei; Xiang, Zhou; Zhong, Gang; Huang, Fu-Guo; Wang, Guang-Lin

    2017-09-01

    To compare the efficacy of sacroiliac joint anterior approach with double reconstruction plate and computer assisted navigation percutaneous sacroiliac screw for treating Tile C1 pelvic fractures. Fifty patients with pelvic Tile C1 fractures were randomly divided into two groups ( n =25 for each) in the orthopedic department of West China Hospital of Sichuan University from December 2012 to November 2014. Patients in group A were treated by sacroiliac joint dislocation with anterior plate fixation. Patients in group B were treated with computerized navigation for percutaneous sacroiliac screw. The operation duration,intraoperative blood loss,incision length,and postoperative complications (nausea,vomiting,pulmonary infection,wound complications,etc.) were compared between the two groups. The postoperative fracture healing time,postoperative patient satisfaction,and postoperative fractures MATTA scores (to evaluate fracture reduction),postoperative MAJEED function scores,and SF36 scores of the patients were also recorded and compared. No significant differences in baseline characteristics were found between the two groups of patients. All of the patients in both groups had their operations successfully completed. Patients in group B had significantly shorter operations and lower intraoperative blood loss,incision length and postoperative complications than those in group A ( P 0.05). Sacroiliac joint anterior approach with double reconstruction plate and computer assisted navigation percutaneous sacroiliac screws are both effective for treating Tile C1type pelvic fractures,with similar longterm efficacies. However,computer assisted navigation percutaneous sacroiliac screw has the advantages of less trauma,less bleeding,and quicker.

  1. Locking plate fixation for proximal humerus fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2012-02-01

    Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for proximal humeral fractures should involve minimal soft tissue dissection and achieve anatomic reduction of the head complex with sufficient stability to allow for early shoulder mobilization. This article reviews various treatment options, in particular locking plate fixation. Locking plate fixation is associated with a high complication rate, such as avascular necrosis (7.9%), screw cutout (11.6%), and revision surgery (13.7%). These complications are frequently due to the varus deformation of the humeral head. Strategic screw placement in the humeral head would minimize the possibility of loss of fracture reduction and potential hardware complications. Locking plate fixation is a good surgical option for the management of proximal humerus fractures. Complications can be avoided by using better bone stock and by careful screw placement in the humeral head.

  2. Clinical comparative analysis on unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation.

    Science.gov (United States)

    Li, C-L

    2014-01-01

    To investigate clinical efficacy of unstable pelvic fractures in the treatment with percutaneous sacroiliac screws and sacroiliac joint anterior plate fixation. 64 patients with unstable pelvic fractures were selected in the hospital from January 2008 to June 2011, and were randomly divided into two groups.(32 patients with sacroiliac anterior plate fixation as the control group, and another 32 patients with percutaneous sacroiliac screw internal fixation as the observation group). The perioperative period clinical indicators, postoperative Matta score, postoperative Majeed function score of all patients were compared and analyzed. The operation time, intraoperative blood loss, wound total length, postoperative fever time, duration of hospitalization in the observation group were significantly less than those in the control group. The complication rate (3.1%) in the observation group was lower than that in the control group (21.9%). The rate of Matta score excellent (96.9%) in the observation group was higher than that in the control group (81.2%) after the treatment. The rate of Majeed function score excellent (93.8%) in the observation group was significantly higher than that in the control group (75%) after the treatment. Percutaneous sacroiliac screw internal fixation in the treatment of unstable pelvic fractures has less injury, less bleeding, less pain and rapid recovery which is a safe and effective minimally invasive operation method. The clinical curative effect of percutaneous sacroiliac screw internal fixation is better than anterior plate fixation for the treatment of sacroiliac joint. The full preparation before the surgery and patients with positive can substantially reduce the occurrence of complications rate.

  3. Stability of midface fracture repair using absorbable plate and screw system pilot holes drilled and pin placement at angles other than 90°.

    Science.gov (United States)

    Carron, Michael A; Zuliani, Giancarlo; Pereira, Lucio; Abuhamdan, Maher; Thibault, Adrianna; Dau, Nathan; Bir, Cynthia

    2014-01-01

    Conventional plating systems use titanium plates for fixation of fractures, with benefits of strength and biocompatibility. However, titanium plates require that screws be placed at a 90° angle to the pilot holes. In the midface, this becomes extremely difficult. Today, a variety of craniomaxillofacial osteosynthesis systems are available, including resorbable plating systems. Specifically, the KLS Martin Sonic Weld system ultrasonically fuses the plate and the head of the pin when placed and will fill the pilot hole grooves completely even at less than 90° angles, which provides a tremendous advantage in midface fracture repair. To determine if the KLS Martin Sonic Weld system provides plate-screw construct stability in human heads even when placed at acute angles at the midface buttresses. DESIGN, SETTING, AND SPECIMENS: Twenty cadaveric head specimens with the mandible removed were prepared by creating osteotomies in the midface buttresses bilaterally. Specimens were defleshed and placed in a 2-part testing rig to hold and position the head for testing in a standard material testing system. Testing was performed at the Wayne State University Bioengineering test laboratories, Detroit, Michigan, using an Instron device and high-speed camera. Specimens were plated on one side of the midface using the KLS Martin Sonic Weld system with pilot holes and pins placed at 90° angles. On the contralateral side, the buttresses were plated with the KLS Martin Sonic Weld system at 60°, 45°, and 30° angles. Data were collected using the TDAS data acquisition system and were compared with matched pairs within each specimen. Ultrasonically vibrated pins placed into absorbable mini-plates at less than 90° angles with the KLS Martin Sonic Weld system were compared with the same amount of stress as the system placed at a 90° angle before demonstrating plate-screw construct failure. RESULTS Fifty-seven paired tests were collected, with 114 total tests. Twenty failures were

  4. Middle-term follow-up results of Pipkin type IV femoral head fracture patients treated by reconstruction plate and bioabsorbable screws

    Directory of Open Access Journals (Sweden)

    Shan-Xi Wang

    2018-06-01

    Full Text Available Purpose: To investigate the mid-term curative effects of the treatment of Pipkin type IV femoral head fractures using a reconstruction plate and bioabsorbable screws and provide the evidence for clinical practice. Methods: From February 2010 to September 2014, 21 patients with Pipkin type IV femoral head fractures were treated surgically. There were 13 males and 8 females with an average age of 41.1 years (range, 20–65 years. The causes of the fractures included traffic accidents (13 cases, falls from a height (four cases, heavy lifting injuries (three cases, and sport injury (one case. All patients were followed up with radiography and three-dimensional reconstruction computed tomography and other checks and any complications were actively managed. Closed reduction of fracture-dislocation of the hip was attempted under general anesthesia using the Kocher-Langenbeck approach. Femoral head fractures were treated with internal fixation or excision based on the size of the fracture fragments, whereas acetabular fractures were fixed with a reconstruction plate and screws following anatomic reduction. Results: The incisions healed by primary intention in all patients after surgery, without any infection, deep venous thrombosis, or other complications. All 21 patients were followed up for 36–76 months, with an average follow-up duration of 49 months. Postoperative imaging data showed that all dislocations and fractures were anatomically reduced, and bony union of the fractures was achieved. Heterotopic ossification was found in four patients, post-traumatic osteoarthritis in three, and avascular necrosis of the femoral head in two. At the final follow-up, the assessment of hip joint function according to the Thompson-Epstein scoring scale was excellent in 10 cases, good in six cases, fair in three cases, and poor in two cases. The rate of excellent and good functional outcomes was 76.1%. Conclusion: The mid-term curative effects of a

  5. Fixation of zygomatic and mandibular fractures with biodegradable plates

    OpenAIRE

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    Context: In this prospective study, 13 randomly selected patients underwent treatment for zygomatic?complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. Aims: To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. Materials and Methods: In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and sc...

  6. Treatment of Displaced Sacroiliac Fracture Using the Lateral Window for Short Plate Buttress Reduction and Percutaneous Sacroiliac Screw Fixation.

    Directory of Open Access Journals (Sweden)

    Colin Murphy

    2016-04-01

    Full Text Available Fractures through the sacroiliac joint are very challenging to treat, technically difficult to reduce through closed methods on account of the multiaxial displacement of fractures fragments, frequently occur in very unwell patients, and have poor outcomes if malreduction is present. We describe a technique utilising the lateral window and a short buttress plate to reduce and stabilize the fragments prior to percutaneous fixation with sacroiliac screws.

  7. Mini-Fragment Fixation Is Equivalent to Bicortical Screw Fixation for Horizontal Medial Malleolus Fractures.

    Science.gov (United States)

    Wegner, Adam M; Wolinsky, Philip R; Robbins, Michael A; Garcia, Tanya C; Amanatullah, Derek F

    2018-05-01

    Horizontal fractures of the medial malleolus occur through application of valgus or abduction force through the ankle that creates a tension failure of the medial malleolus. The authors hypothesize that mini-fragment T-plates may offer improved fixation, but the optimal fixation construct for these fractures remains unclear. Forty synthetic distal tibiae with identical osteotomies were randomized into 4 fixation constructs: (1) two parallel unicortical cancellous screws; (2) two parallel bicortical cortical screws; (3) a contoured mini-fragment T-plate with 2 unicortical screws in the fragment and 2 bicortical screws in the shaft; and (4) a contoured mini-fragment T-plate with 2 bicortical screws in the fragment and 2 unicortical screws in the shaft. Specimens were subjected to offset axial tension loading on a servohydraulic testing system and tracked using high-resolution video. Failure was defined as 2 mm of articular displacement. Analysis of variance followed by a Tukey-Kramer post hoc test was used to assess for differences between groups, with significance defined as Pfragment T-plate constructs (239±83 N/mm and 190±37 N/mm) and the bicortical screw construct (240±17 N/mm) were not statistically different. The mean stiffness values of both mini-fragment T-plate constructs and the bicortical screw construct were higher than that of a parallel unicortical screw construct (102±20 N/mm). Contoured T-plate constructs provide stiffer initial fixation than a unicortical cancellous screw construct. The T-plate is biomechanically equivalent to a bicortical screw construct, but may be superior in capturing small fragments of bone. [Orthopedics. 2018; 41(3):e395-e399.]. Copyright 2018, SLACK Incorporated.

  8. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study.

    Science.gov (United States)

    Bali, Rishi K; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-07-01

    The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required.

  9. Fixation of zygomatic and mandibular fractures with biodegradable plates.

    Science.gov (United States)

    Degala, Saikrishna; Shetty, Sujeeth; Ramya, S

    2013-01-01

    In this prospective study, 13 randomly selected patients underwent treatment for zygomatic-complex fractures (2 site fractures) and mandibular fractures using 1.5 / 2 / 2.5-mm INION CPS biodegradable plates and screws. To assess the fixation of zygomatic-complex and mandibular fractures with biodegradable copolymer osteosynthesis system. In randomly selected 13 patients, zygomatic-complex and mandibular fractures were plated using resorbable plates and screws using Champy's principle. All the cases were evaluated clinically and radiologically for the type of fracture, need for the intermaxillary fixation (IMF) and its duration, duration of surgery, fixation at operation, state of reduction at operation, state of bone union after operation, anatomic reduction, paresthesia, occlusal discrepancies, soft tissue infection, immediate and late inflammatory reactions related to biodegradation process, and any need for the removal of the plates. Descriptives, Frequencies, and Chi-square test were used. In our study, the age group range was 5 to 55 years. Road traffic accidents accounted for the majority of patients six, (46.2%). Postoperative occlusal discrepancies were found in seven patients as mild to moderate, which resolved with IMF for 1-8 weeks. There were minimal complications seen and only as soft tissue infection. Use of biodegradable osteosynthesis system is a reliable alternative method for the fixation of zygomatic-complex and mandibular fractures. The biodegradable system still needs to be refined in material quality and handling to match the stability achieved with metal system. Biodegradable plates and screws is an ideal system for pediatric fractures with favorable outcome.

  10. A STUDY ON PROXIMAL HUMERAL FRACTURES STABILISED WITH PHILOS PLATE

    Directory of Open Access Journals (Sweden)

    Praveen Sivakumar K

    2017-02-01

    Full Text Available BACKGROUND Techniques for treating complex proximal humeral fractures vary and include fixations using tension bands, percutaneous pins, bone suture, T-plates, intramedullary nails, double tubular plates, hemiarthroplasty, plant tan humerus fixator plates, Polaris nails and blade plates. Complications of these techniques include cutout or back out of the screws and plates, avascular necrosis, nonunion, malunion, nail migration, rotator cuff impairment and impingement syndromes. Insufficient anchorage from conventional implants may lead to early loosening and failure, especially in osteoporotic bones. In general, nonoperative treatment of displaced three and four-part fractures of the proximal humerus leads to poor outcome due to intraarticular nature of injury and inherent instability of the fragments. Comminuted fractures of the proximal humerus are at risk of fixation failure, screw loosening and fracture displacement. Open reduction and internal fixation with conventional plate and screws has been associated with unacceptably high incidence of screw pull out. PHILOS (the proximal humeral internal locking system plate is an internal fixation system that enables angled stabilisation with multiple interlocking screws for fractures of the proximal humerus. MATERIALS AND METHODS 30 patients with proximal humerus fractures who were admitted in the Department of Orthopaedics, Government General Hospital, Kakinada, during the period November 2014 - November 2016 were taken up for study according to inclusion criteria. All patients were treated with PHILOS plate. These proximal humerus fractures were classified according to Neer’s classification. Patients were followed up at 6 weeks, 12 weeks and 6 months’ interval. Functional outcomes for pain, range of motion and muscle power and function were assessed using the Constant-Murley scoring system. Collected data analysed with independent t-test and ANNOVA test. RESULTS The outcome of the study was 1

  11. Sliding-screw plate fixation of proximal femoral fractures: Radiographic assessment

    Energy Technology Data Exchange (ETDEWEB)

    Sartoris, D.J.; Resnick, D.; Kerr, R.; Goergen, T.

    1985-07-01

    The sliding compression screw-sideplate combination is currently the most widely employed device for internal fixation of stable and unstable intertrochanteric fractures of the femur. The normal and abnormal radiographic appearances of this device in the immediate post-operative period are discussed. Potential long-term complications including mal- or non-union, intra-articular penetration, metal failure, rotation of the proximal fracture fragment, disengagement, trochanteric bursitis, leg length discrepancy, delayed cervical stress fracture, and ischemic necrosis are reviewed.

  12. Sliding-screw plate fixation of proximal femoral fractures: Radiographic assessment

    International Nuclear Information System (INIS)

    Sartoris, D.J.; Resnick, D.; California Univ., San Diego, La Jolla; Kerr, R.; Goergen, T.

    1985-01-01

    The sliding compression screw-sideplate combination is currently the most widely employed device for internal fixation of stable and unstable intertrochanteric fractures of the femur. The normal and abnormal radiogrpahic appearances of this device in the immediate post-operative period are discussed. Potential long-term complications including mal- or non-union, intra-articular penetration, metal failure, rotation of the proximal fracture fragment, disengagement, trochanteric bursitis, leg length discrepancy, delayed cervical stress fracture, and ischemic necrosis are reviewed. (orig.)

  13. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    Science.gov (United States)

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  14. Comparison of Neck Screw and Conventional Fixation Techniques in Mandibular Condyle Fractures Using 3-Dimensional Finite Element Analysis.

    Science.gov (United States)

    Conci, Ricardo Augusto; Tomazi, Flavio Henrique Silveira; Noritomi, Pedro Yoshito; da Silva, Jorge Vicente Lopes; Fritscher, Guilherme Genehr; Heitz, Claiton

    2015-07-01

    To compare the mechanical stress on the mandibular condyle after the reduction and fixation of mandibular condylar fractures using the neck screw and 2 other conventional techniques according to 3-dimensional finite element analysis. A 3-dimensional finite element model of a mandible was created and graphically simulated on a computer screen. The model was fixed with 3 different techniques: a 2.0-mm plate with 4 screws, 2 plates (1 1.5-mm plate and 1 2.0-mm plate) with 4 screws, and a neck screw. Loads were applied that simulated muscular action, with restrictions of the upper movements of the mandible, differentiation of the cortical and medullary bone, and the virtual "folds" of the plates and screws so that they could adjust to the condylar surface. Afterward, the data were exported for graphic visualization of the results and quantitative analysis was performed. The 2-plate technique exhibited better stability in regard to displacement of fractures, deformity of the synthesis materials, and minimum and maximum tension values. The results with the neck screw were satisfactory and were similar to those found when a miniplate was used. Although the study shows that 2 isolated plates yielded better results compared with the other groups using other fixation systems and methods, the neck screw could be an option for condylar fracture reduction. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Treatment of segmental tibial fractures with supercutaneous plating.

    Science.gov (United States)

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  16. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    Science.gov (United States)

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  17. Effect of screw position on single cycle to failure in bending and torsion of a locking plate-rod construct in a synthetic feline femoral gap model.

    Science.gov (United States)

    Niederhäuser, Simone K; Tepic, Slobodan; Weber, Urs T

    2015-05-01

    To evaluate the effect of screw position on strength and stiffness of a combination locking plate-rod construct in a synthetic feline femoral gap model. 30 synthetic long-bone models derived from beechwood and balsa wood. 3 constructs (2 locking plate-rod constructs and 1 locking plate construct; 10 specimens/construct) were tested in a diaphyseal bridge plating configuration by use of 4-point bending and torsion. Variables included screw position (near the fracture gap and far from the fracture gap) and application of an intramedullary pin. Constructs were tested to failure in each loading mode to determine strength and stiffness. Failure was defined as plastic deformation of the plate or breakage of the bone model or plate. Strength, yield angle, and stiffness were compared by use of a Wilcoxon test. Placement of screws near the fracture gap did not increase bending or torsional stiffness in the locking plate-rod constructs, assuming the plate was placed on the tension side of the bone. Addition of an intramedullary pin resulted in a significant increase in bending strength of the construct. Screw positioning did not have a significant effect on any torsion variables. Results of this study suggested that, in the investigated plate-rod construct, screw insertion adjacent to the fracture lacked mechanical advantages over screw insertion at the plate ends. For surgeons attempting to minimize soft tissue dissection, the decision to make additional incisions for screw placement should be considered with even more caution.

  18. Surgical treatment of sagittal fracture of mandibular condyle using long-screw osteosynthesis.

    Science.gov (United States)

    Luo, Shufang; Li, Bo; Long, Xing; Deng, Mohong; Cai, Hengxing; Cheng, Yong

    2011-07-01

    The retrospective study evaluated long-screw (bicortical screw) osteosynthesis used in the surgical treatment of sagittal fracture of the mandibular condyle and compared it with titanium plates and removal of the condylar fragment. Ninety-five patients with sagittal fracture of the mandibular condyle received open surgical treatment from 1997 to 2008. Among these patients, the condylar fragments were fixed with long screws in 56 cases (group A), were fixed with titanium plates in 12 cases (group B), and were completely removed in 24 cases (group C). Follow-up was carried out clinically and radiologically. The clinical features included limitation of mandibular mobility, occlusion disturbance, lateral deviation on mouth opening, joint pain, clicking, facial asymmetry, and patient's subjective evaluation. The radiologic parameters consisted of degree of bony resorption, bony change, change of osteosynthesis material, and shortening of mandibular ramus height. Anatomic reduction and functional restoration were obtained and no severe complication was detected in group A. However, 3 of 14 patients had severe osteoarthrosis and 2 of 14 patients had ankylosis in group B. In group C 3 of 24 patients had mandibular retrusion, 4 of 24 patients had front teeth open bite, 4 of 24 patients had severe osteoarthrosis, and 1 of 24 patients had ankylosis. The long-screw fixation group had a more favorable prognosis than the titanium plate group and the group in which removal of the condylar fragment was performed. The long-screw fixation technique might be suitable for use in the surgical treatment of sagittal fractures of the mandibular condyle. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Influence of glide path on the screw-in effect and torque of nickel-titanium rotary files in simulated resin root canals

    Directory of Open Access Journals (Sweden)

    Jung-Hong Ha

    2012-11-01

    Full Text Available Objectives The purpose of this study was to investigate the screw-in effect and torque generation depending on the size of glide path during root canal preparation. Materials and Methods Forty Endo-Training Blocks (REF A 0177, Dentsply Maillefer were used. They were divided into 4 groups. For groups 1, 2, 3, and 4, the glide path was established with ISO #13 Path File (Dentsply Maillefer, #15 NiTi K-file NITIFLEX (Dentsply Maillefer, modified #16 Path File (equivalent to #18, and #20 NiTi K-file NITIFLEX, respectively. The screw-in force and resultant torque were measured using a custom-made experimental apparatus while canals were instrumented with ProTaper S1 (Dentsply Maillefer at a constant speed of 300 rpm with an automated pecking motion. A statistical analysis was performed using one-way analysis of variance and the Duncan post hoc comparison test. Results Group 4 showed lowest screw-in effect (2.796 ± 0.134 among the groups (p < 0.05. Torque was inversely proportional to the glide path of each group. In #20 glide path group, the screw-in effect and torque decreased at the last 1 mm from the apical terminus. However, in the other groups, the decrease of the screw-in effect and torque did not occur in the last 1 mm from the apical terminus. Conclusions The establishment of a larger glide path before NiTi rotary instrumentation appears to be appropriate for safely shaping the canal. It is recommended to establish #20 glide path with NiTi file when using ProTaper NiTi rotary instruments system safely.

  20. Percutaneous Intramedullary Screw Fixation of Distal Fibula Fractures: A Case Series and Systematic Review

    NARCIS (Netherlands)

    Loukachov, Vladimir V.; Birnie, Merel F. N.; Dingemans, Siem A.; de Jong, Vincent M.; Schepers, Tim

    2017-01-01

    The current reference standard for unstable ankle fractures is open reduction and internal fixation using a plate and lag screws. This approach requires extensive dissection and wound complications are not uncommon. The use of intramedullary screw fixation might overcome these issues. The aim of our

  1. A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

    Directory of Open Access Journals (Sweden)

    Prakash Jayakumar

    2015-04-01

    Full Text Available Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking screw, which must also avoid the olecranon, coronoid, and radial fossae. We describe 3 patients (ages 27, 49, and 73 years with a bicolumnar fracture of the distal humerus where very short distal locking screws were used. Intra-articular screw placement was avoided but loss of fixation occurred in two patients and a third was treated with a prolonged period of immobilization. We postulate that fixed-angle screw trajectories may make it difficult for the surgeon to place screws of adequate length in this anatomically confined region, and may lead to insufficient distal fixation. Surgical tactics should include placement of as many screws as possible into the distal fragment, as long as possible, and that each screw pass through a plate without necessarily locking in.

  2. [Fracture of implant abutment screws and removal of a remaining screw piece

    NARCIS (Netherlands)

    Broeke, S.M. van den; Baat, C. de

    2008-01-01

    Fracture of the implant abutment screws is a complication which can render an implant useless. The prevalence of abutment screw fracture does not exceed 2.5% after 10 years. Causes are loosening of implant abutment screw, too few, too short or too narrow implants, implants not inserted perpendicular

  3. Fixed-angle plates in patella fractures - a pilot cadaver study

    Directory of Open Access Journals (Sweden)

    Wild M

    2011-01-01

    Full Text Available Abstract Objective Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella. Methods In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge, quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made. Results Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65. Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed. Conclusions Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays

  4. Scaphoid Fracture Fixation with an Acutrak? Screw

    OpenAIRE

    Loving, Vilert A.; Richardson, Michael L.

    2015-01-01

    We report a case of fixation of a scaphoid fracture using an Acutrak? screw. This screw is cannulated and headless, which allows it to be implanted below the surface of the bone. It uses the same concept of variable thread pitch as the Herbert screw, but unlike the Herbert screw, is fully threaded, with continuously varying pitch along its length. This variable pitch creates constant compression across a fracture as the screw is advanced, and gives the screw its unique appearance. This featur...

  5. Less invasive plate osteosynthesis in humeral shaft fractures.

    Science.gov (United States)

    Apivatthakakul, Theerachai; Phornphutkul, Chanakarn; Laohapoonrungsee, Anupong; Sirirungruangsarn, Yuddhasert

    2009-12-01

    Stable internal fixation of the humeral shaft by less invasive percutaneous plate insertion using two separate (proximal and distal) incisions, indirect reduction by closed manipulation and fixation to preserve the soft tissue and blood supply at the fracture zone. Early mobilization of the shoulder and elbow to ensure a good functional outcome. Humeral shaft fractures (classified according to AO classification as: 12-A, B, C). Humeral shaft fractures extending to the proximal or distal shaft, small or deformed medullary canal or open growth plate. Humeral shaft fractures with primary radial nerve palsy. Proximal humeral shaft fractures extending to the humeral head. Distal humeral fractures extending to the elbow joint. Two incisions proximal and distal to the fracture zone are used. A 3-cm proximal incision lies between the lateral border of the proximal part of the biceps and the medial border of the deltoid. Distally, a 3-cm incision is made along the lateral border of the biceps. The interval between biceps and brachialis is identified. The biceps is retracted medially to expose the musculocutaneous nerve. The brachialis muscle has dual innervation, the medial half being innervated by the musculocutaneous nerve and the lateral half by the radial nerve. The brachialis is split longitudinally at its midline. The musculocutaneous nerve is retracted along with the medial half of the brachialis, while the lateral half of the brachialis serves as a cushion to protect the radial nerve. A deep subbrachial tunnel is created from the distal to the proximal incision. The selected plate is tied with a suture to a hole at the tip of the tunneling instrument for pulling the plate back along the prepared track. The plate is aligned in the correct position on the anterior surface of the humerus. Traction is applied and the fracture reduced to restore alignment by image intensifier, followed by plate fixation with at least two bicortical locking screws or three bicortical

  6. [The rotationally stable screw-anchor with trochanteric stabilizing plate (RoSA/TSP) : First results in unstable trochanteric femur fractures].

    Science.gov (United States)

    Maier, K-J; Bücking, B; Horst, K; Andruszkow, H; Hildebrand, F; Knobe, M

    2017-12-01

    In unstable trochanteric fractures, the extramedullary rotationally stable screw-anchor (RoSA) combines the benefits of the load and rotational stability of the blade with the advantages of the screw (pull-out resistance, compression capability) in a single load carrier, and was designed to prevent femoral neck shortening by using an additional locked trochanteric stabilizing plate (TSP). The aim of the current prospective cohort study was the clinical evaluation of the RoSA/TSP system regarding the mechanical re-operation rate and the amount of postoperative femoral neck shortening. From September 2011 to January 2014 80 patients with unstable trochanteric fractures underwent internal extramedullary fixation with the RoSA/TSP (Königsee Implantate GmbH, Allendorf, Germany). Due to fracture stability and after induction of compression, additional long locked antitelescoping screws (AT, n = 1-4) were placed reaching the femoral head. Radiological (femoral neck shortening) and clinical re-examination of patients (n = 61) was performed 6-10 weeks and 6-10 months later. In the 61 re-examined patients (76 %) femoral neck shortening was very low with 2 mm 6-10 months after operation. Re-operations occurred in 8 % (n = 6) and in 4 % (n = 3) as prophylactic surgical intervention. Whereas one-third (4 %) of re-operations occurred due to iatrogenic surgical problems from the first operation two-thirds of patients (8 %) had a re-operation due to delay of bone union (3× nonunion, 3 planned removals of AT-screws to improve healing). The in-hospital mortality was 3 % (n = 2). The fixation of unstable trochanteric femur fractures using the RoSA/TSP in a first clinical setting led to a great primary stability, with significant advantages with regard to limited femoral neck shortening. However, the rigidity of the construct with its consequences regarding bone healing can be challenging for the surgeon. Nevertheless, in some cases of revision it could be beneficial

  7. Biomechanical study: resistance comparison of posterior antiglide plate and lateral plate on synthetic bone models simulating Danis-Weber B malleolar fractures

    Directory of Open Access Journals (Sweden)

    Bruna Buscharino

    2013-06-01

    Full Text Available OBJECTIVE : The purpose of this study was to compare different positions of plates in lateral malleolar Danis-Weber B fractures on synthetic bone: a lateral plate and a posterior antiglide plate. METHODS : Short oblique fractures of distal fibula at the level of the syndesmosys were simulated with a fibular osteotomy in sixteen synthetic fibula bones (Synbone®. Eight fractures were fixed with lateral plating associated with an independent lag screw, and the other eight were fixed with posterior antiglide plating with a lag screw through the plate. A strain gage was installed at the center of each plate at the osteotomy site. Supination and external rotation forces were applied to each of the two groups at the bend. RESULTS : The lateral position plate group suffered more deformity in response to supination forces compared to the group with the posterior antiglide plate, but this result was not statistically significant. In the tests with external rotation forces, the posterior antiglide plating group had significantly higher resistance (p < 0.05. CONCLUSION : When subjected to external rotation forces, osteosynthesis with posterior antiglide plate models simulating type B fractures of the lateral malleolus of the ankle is more resistant than that of the neutralization plate.

  8. Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis.

    Directory of Open Access Journals (Sweden)

    Ke Su

    Full Text Available The purpose of this study was to compare the stability and feasibility of four fixation constructs in a posterior column acetabular fracture: one reconstruction plate, one reconstruction plate and lag screw, two reconstruction plates, and a W-shaped acetabular angular plate.Twenty embalmed cadaveric pelvises with a posterior column acetabular fractures were allocated to one of four groups: 1 a reconstruction plate, 2 a reconstruction plate with a posterior column lag screw, 3 double reconstruction plates, and 4 a W-shaped acetabular angular plate. These constructs were mechanically loaded on a testing machine, and construct stiffness values were measured. Strain gauges were utilized to measure the mechanical behavior in the condition of compressive force.Final stiffness was not different between the two reconstruction plates (445.81±98.30 N/mm and the W-shaped acetabular angular plate (447.43±98.45 N/mm, p = 0.524, both of which were superior to a single reconstruction plate (248.90±61.95 N/mm and a combined plate and lag screw (326.41±94.34 N/mm. Following the fixation of the W-shaped acetabular angular plate, the strain distribution was similar to the intact condition around the acetabulum. The parameters of the W-shaped acetabular angular plate that were observed at the superior region of the acetabulum were less than those of a single reconstruction plate (p<0.05, a single reconstruction plate with lag screw (p<0.05, and two reconstruction plates (p<0.05.The novel W-shaped acetabular angular plate fixation technique was able to provide the biomechanically stiffest construct for stabilization of a posterior column acetabular fracture; it also resulted in a partial restoration of joint loading parameters toward the intact state.

  9. Volar plating for distal radius fractures--do not trust the image intensifier when judging distal subchondral screw length.

    Science.gov (United States)

    Park, Derek H; Goldie, Boyd S

    2012-09-01

    The use of the volar plate to treat distal radius fractures is increasing but despite the theoretical advantages of a volar approach there have been reports of extensor tendon ruptures due to prominent screw tips protruding past the dorsal cortex. The valley in the intermediate column between Lister tubercle and the sigmoid notch of the distal radius makes it difficult to rely on fluoroscopy to judge screw length. Our aim was to quantify the dimensions of this valley and to demonstrate the danger of relying on intraoperative image intensification fluoroscopy to determine lengths of distal screws. We measured the depth of this valley in the intermediate column of the distal radius in 33 patients with computed tomographic (9 patients) or magnetic resonance image (24 patients) scans of the wrist. There was a consistent valley in all images examined [average 1.8 mm (95% confidence interval, 1.6-2.0 mm)]. Thirty-nine percent of wrists had a valley depth of at least 2 mm. Standard lateral views or rotation of the forearm to obtain oblique views does not identify prominent screw tips; and whatever the rotation of the forearm, screw tips protruding beyond dorsal cortex may look as if it is within the bone when in fact it is out. When drilling we suggest noting the depth at which the drill bit just penetrates dorsal cortex and routinely downsize the distal screw length by 2 mm. We caution against relying on flourosocopy when judging the length of the distal subchondral screws.

  10. Filling Open Screw Holes in the Area of Metaphyseal Comminution Does Not Affect Fatigue Life of the Synthes Variable Angle Distal Femoral Locking Plate in the AO/OTA 33-A3 Fracture Model.

    Science.gov (United States)

    Grau, Luis; Collon, Kevin; Alhandi, Ali; Kaimrajh, David; Varon, Maria; Latta, Loren; Vilella, Fernando

    2018-06-01

    The aim of this study is to evaluate the biomechanical effect of filling locking variable angle (VA) screw holes at the area of metaphyseal fracture comminution in a Sawbones® (Sawbones USA, Vashon, Washington) model (AO/OTA 33A-3 fracture) using a Synthes VA locking compression plate (LCP) (Depuy Synthes, Warsaw, Indiana). Seven Sawbones® femur models had a Synthes VA-LCP placed as indicated by the manufacturers technique. A 4cm osteotomy was then created to simulate an AO/OTA 33-A3 femoral fracture pattern with metaphyseal comminution. The control group consisted of four constructs in which the open screw holes at the area of comminution were left unfilled; the experimental group consisted of three constructs in which the VA screw holes were filled with locking screws. One of the control constructs was statically loaded to failure at a rate of 5mm/min. A value equal to 75% of the ultimate load to failure was used as the loading force for fatigue testing of 250,000 cycles at 3Hz. Cycles to failure was recorded for each construct and averages were compared between groups. The average number of cycles to failure in the control and experimental groups were 37524±8187 and 43304±23835, respectively (p=0.72). No significant difference was observed with respect to cycles to failure or mechanism of failure between groups. In all constructs in both the control and experimental groups, plate failure reproducibly occurred with cracks through the variable angle holes in the area of bridged comminution. The Synthes VA-LCP in a simulated AO/OTA 33-A3 comminuted metaphyseal femoral fracture fails in a reproducible manner at the area of comminution through the "honeycomb" VA screw holes. Filling open VA screw holes at the site of comminution with locking screws does not increase fatigue life of the Synthes VA-LCP in a simulated AO/OTA 33-A3 distal femoral fracture. Further studies are necessary to determine whether use of this particular plate is contraindicated when bridging

  11. Release of metal in vivo from stressed and nonstressed maxillofacial fracture plates and screws.

    Science.gov (United States)

    Matthew, I R; Frame, J W

    2000-07-01

    To analyze the release of metal into the adjacent tissues from stressed and nonstressed titanium and stainless steel miniplates and screws. Two miniplates were inserted into the cranial vaults of 12 beagle dogs while they were under general endotracheal anesthesia. One miniplate was shaped to fit the curvature of the skull (control). Another miniplate, made of the same material, was bent in a curve until the midpoint was raised 3 mm above the ends. Screws were inserted and tightened until the plate conformed to the skull curvature, creating stresses in the system. Four animals (2 each, having titanium or stainless steel plates and screws) were killed after 4, 12, and 24 weeks. Metallosis of adjacent soft tissues was assessed qualitatively. Miniplates and screws were removed, and adjacent soft tissue and bone was excised. Titanium, iron, chromium, nickel, and aluminum levels were assayed by ultraviolet/visible light and atomic absorption spectrophotometry. Nonparametric statistical methods were used for data analysis. There was no clear relationship between pigmentation of soft tissue adjacent to the miniplates and screws and the concentrations of metal present. The data did not demonstrate any consistent differences in the concentrations of metallic elements next to stressed and nonstressed (control) miniplates and screws of either material. Stresses arising through poor contouring of miniplates do not appear to influence the extent of release of metal into the adjacent tissues.

  12. [Comparison of screw' inserting angle through the 11th and 12th rib anterior approaches for L1 burst fracture].

    Science.gov (United States)

    Ma, Li-Tai; Liu, Hao; Li, Tao; Song, Yue-Ming; Pei, Fu-Xing; Liu, Li-Min; Gong, Quan; Zeng, Jian-Cheng; Feng, Gan-Jun; Zhou, Zhong-Jie

    2012-12-01

    To compare screw's inserting angle through the 11th and 12th rib in treating L1 burst fracture, explore effects on inserting screw and postoperative angle. From October 2007 to October 2010, 108 patients with L1 brust fracture treated through anterior approach were analyzed,including 68 males and 40 females, aged from 21 to 64 years (mean 38.22 years). All patients were divided into the 11th (A, 51 cases) and 12th (B, 57 cases) approach. The data of operation time,blood loss, duration of incision pain, JOA score, Oswestry score, VAS score, quality of life (SF-36), recovery of nervous function, coronal Cobb angle, included angle between screw and plate were observed. All patients were followed up for 9 to 37 months, mean 23 months. The operation time, blood loss, duration of incision pain, in group A were lower than group B (P0.05). There were no differences in Cobb angle before operation, but had significance after operation (P=0.000). There were statistically significance between two group in angle between screw and plate (P=0.000, P=0.003). The 11th rib approach for the treatment of L1 burst fracture has less effects on screw, less trauma and less angle between screw and plate.

  13. In vivo study of magnesium plate and screw degradation and bone fracture healing.

    Science.gov (United States)

    Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Myers, Nicole; Costello, Bernard J; Chou, Da-Tren; Pal, Siladitya; Maiti, Spandan; Kumta, Prashant N; Sfeir, Charles

    2015-05-01

    Each year, millions of Americans suffer bone fractures, often requiring internal fixation. Current devices, like plates and screws, are made with permanent metals or resorbable polymers. Permanent metals provide strength and biocompatibility, but cause long-term complications and may require removal. Resorbable polymers reduce long-term complications, but are unsuitable for many load-bearing applications. To mitigate complications, degradable magnesium (Mg) alloys are being developed for craniofacial and orthopedic applications. Their combination of strength and degradation make them ideal for bone fixation. Previously, we conducted a pilot study comparing Mg and titanium devices with a rabbit ulna fracture model. We observed Mg device degradation, with uninhibited healing. Interestingly, we observed bone formation around degrading Mg, but not titanium, devices. These results highlighted the potential for these fixation devices. To better assess their efficacy, we conducted a more thorough study assessing 99.9% Mg devices in a similar rabbit ulna fracture model. Device degradation, fracture healing, and bone formation were evaluated using microcomputed tomography, histology and biomechanical tests. We observed device degradation throughout, and calculated a corrosion rate of 0.40±0.04mm/year after 8 weeks. In addition, we observed fracture healing by 8 weeks, and maturation after 16 weeks. In accordance with our pilot study, we observed bone formation surrounding Mg devices, with complete overgrowth by 16 weeks. Bend tests revealed no difference in flexural load of healed ulnae with Mg devices compared to intact ulnae. These data suggest that Mg devices provide stabilization to facilitate healing, while degrading and stimulating new bone formation. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  14. Degradation behaviour of LAE442-based plate-screw-systems in an in vitro bone model.

    Science.gov (United States)

    Wolters, Leonie; Besdo, Silke; Angrisani, Nina; Wriggers, Peter; Hering, Britta; Seitz, Jan-Marten; Reifenrath, Janin

    2015-04-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate-screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15cNm or 7cNm, NaOH treated plates (15cNm), magnesium fluoride coated plates (15cNm) and steel plates as control (15cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Evaluation of selected mechanical properties of NiTi rotary glide path files manufactured from controlled memory wires.

    Science.gov (United States)

    Nishijo, Miki; Ebihara, Arata; Tokita, Daisuke; Doi, Hisashi; Hanawa, Takao; Okiji, Takashi

    2018-03-28

    This study aimed to investigate mechanical properties related to flexibility and fracture resistance of controlled memory wiremanufactured nickel-titanium rotary glide path files [HyFlex EDM Glide Path File (EDM) and HyFlex GPF (GPF)]. Scout RaCe (RaCe) served as control. Bending loads, torsional/cyclic fatigue resistance, and screw-in forces were measured. EDM showed a significantly larger torque at fracture, a longer time to cyclic fracture in reciprocation and a larger screw-in force compared with GPF and RaCe. GPF showed significantly lower bending loads and higher angular deflection values than EDM and RaCe, and a significantly longer time to cyclic fracture than RaCe. The time to cyclic fracture was significantly longer in reciprocation compared with continuous rotation in EDM and GPF. It can be concluded that EDM and/or GPF showed higher flexibility and cyclic/torsional fatigue resistance compared with RaCe; and that reciprocation conferred better cyclic fatigue resistance to EDM and GPF.

  16. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    OpenAIRE

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access ...

  17. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study

    OpenAIRE

    Bali, Rishi K.; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-01-01

    Aims: The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. Materials and Methods: This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inio...

  18. Removal torque of nail interlocking screws is related to screw proximity to the fracture and screw breakage.

    Science.gov (United States)

    White, Alexander A; Kubacki, Meghan R; Samona, Jason; Telehowski, Paul; Atkinson, Patrick J

    2016-06-01

    Studies have shown that titanium implants can be challenging to explant due to the material's excellent biocompatibility and resulting osseointegration. Clinically, titanium alloy nail interlocking screws may require removal to dynamize a construct or revise the nail due to nonunion, infection, pain, or periprosthetic fracture. This study was designed to determine what variables influence the removal torque for titanium alloy interlocking screws. An intramedullary nail with four interlocking screws was used to stabilize a 1-cm segmental femoral defect in a canine model for 16 weeks. The animals were observed to be active following a several-day recovery after surgery. In six animals, the femora and implanted nail/screws were first tested to failure in torsion to simulate periprosthetic fracture of an implant after which the screws were then removed. In four additional animals, the screws were removed without mechanical testing. Both intraoperative insertional and extraction torques were recorded for all screws. Mechanical testing to failure broke 10/24 screws. On average, the intact screws required 70% of the insertional torque during removal while broken screws only required 16% of the insertional torque (p torque than the outboard distal screw (p torque was ∼80°. The peak axial load did not significantly correlate with the torque required to remove the screws. On average, the removal torque was lower than at the time of insertion, and less torque was required to remove broken screws and screws remote to the fracture. However, broken screws will require additional time to retrieve the remaining screw fragment. This study suggests that broken screws and screws in prematurely active patients will require less torque to remove. © IMechE 2016.

  19. [Osteosynthesis of Weber B ankle fractures using the one-third tubular plate and refixation of the syndesmosis].

    Science.gov (United States)

    Spering, C; Lesche, V; Dresing, K

    2015-08-01

    Anatomical reconstruction and recovery to complete range of function of the upper ankle joint. Therefore, the most stable but least invasive osteosynthesis is required to enable the patient early functional mobilization. Supination and pronation fracture with luxation mechanism of the upper ankle joint with or without rupture of the syndesmosis. Open fracture of the distal fibula including displaced and instable fractures. Severe peripheral arterial occlusive disease; contaminated open fractures (≥ 2nd degree); pediatric fractures with open epiphyseal plate. Supine position with ipsilateral slightly elevated hip and knee. Incision of about 8 cm length along the dorsal edge of the distal fibula. When reaching the lateral malleolus, a slight ventral angulation is necessary. Open reduction through this posterolateral approach. Secure the reposition using an interfragmentary lag screw and anatomically adjusted third tubular plate. Followed by a revision of the syndesmosis and transfixation using a tricortical position screw. Mobilization on day 1 after surgery with reduced weight-bearing when position screw is not applied; when position screw is implanted with ground contact for 6 weeks. Removal of position screw under local anesthesia after 6 weeks and pain-controlled full weight-bearing. Removal of metal after 1.5 years. Open reduction using the third tubular plate and an interfragmentary lag screw through a dorsolateral approach used in 90 % of all Weber B fractures in our clinic. Additional revision of a ruptured syndesmosis performed in 70 % and transfixation through a position screw in 40 %. Persisting instability in the upper ankle joint significantly reduced after surgical treatment compared to a conservative approach. Revisions necessary in 3.7 % of patients and pseudarthrosis diagnosed in 0.9 %. It has been shown that the preoperative x-ray and clinical examination is limited in detecting a ruptured syndesmosis.

  20. Outcomes of Distal Femur Fracture Treated with Dynamic Condylar Screw

    International Nuclear Information System (INIS)

    Razaq, M. N. U.; Muhammad, T.; Ahmed, A.; Adeel, M.; Ahmad, S.; Ahmad, S.; Sultan, S.

    2016-01-01

    Background: Implants for open reduction and internal fixation of distal femoral fracture includes angle blade plate, rush nails, enders nail and interlocking nails. But all these devices are technically demanding and less effective in providing inter-fragmentary compression in osteoporotic bones. These problems can be solved with dynamic condylar screw (DCS).The objective of the study was to determine the frequency of different outcomes of distal femoral fracture treated with dynamic condylar screw Methods: This case series study was carried out in the Department of Trauma and Orthopaedics, Ayub Teaching Hospital Abbottabad from 1st October 2014 to August 2015, after approval of the ethical committee of the institution. Data of all patients with distal femoral fractures aged 20-70 years, recruited through emergency, OPD or consultant clinic collected on a proforma. Standard treatment of trauma was given to the patients. Detailed history was taken including the past medical and surgical history. Detailed examination including air-way, breathing and circulation, general physical examination and abdomino-pelvic examination was done in each patient. Investigations including urinalysis, haemoglobin percent, full blood count, X-ray (both AP and lateral view) of the involved femur (including hip and knee) was done. Results: Mean age of the patients was 43.18±14.647 ranging from 20 to 70 years. Mean duration of hospital stay in days was 2.21±1.111 ranging from 1 to 6 days. Patients follow-up assessment after 4 months of surgery for union of femoral fracture treated with dynamic condylar screw was found in 96 (94.1 percent), wound infection was found in 7 (6.9 percent), knee stiffness was found in 21 (20.6 percent) and limb shortening was found in 7 (6.9 percent). Conclusion: Dynamic condylar screw is an easy, scientifically less difficult and satisfying method of treatment for fractures of femur. (author)

  1. Comparison of circummandibular wiring with resorbable bone plates in pediatric mandibular fractures.

    Science.gov (United States)

    Saikrishna, D; Gupta, Nimish

    2010-06-01

    Pediatric patients present a unique challenge to maxillofacial surgeons in terms of their treatment planning as well as in their functional and nutritional needs which are different from that of adult patients. Early literature has advocated conservative closed management of pediatric fractures to prevent complications. However recent advances in maxillofacial surgery has enabled us to use biodegradable plates and screws, which overcomes the limitations of metallic plates. We present a comparison of two cases of parasymphysis fracture treated with circum-mandibular wiring and biodegradable plate fixation their outcome in terms of fracture healing and functional stability.

  2. Percutaneous sacroiliac screw versus anterior plating for sacroiliac joint disruption: A retrospective cohort study.

    Science.gov (United States)

    Zhang, Ruipeng; Yin, Yingchao; Li, Shilun; Hou, Zhiyong; Jin, Lin; Zhang, Yingze

    2018-02-01

    Sacroiliac joint disruption (SJD) is a common cause of pelvic ring instability. Clinically, percutaneous unilateral S1 sacroiliac screw and anterior plating are always applied to manage SJD. The objective of this study is to elaborate their respective therapeutic traits. Patients with SJD fixed with unilateral S1 sacroiliac screw or anterior plating from June 2011 to June 2015 were recruited into this study and were divided into two groups: group A (unilateral sacroiliac screw) and group B (anterior plating). Surgical time, blood loss, frequency of intraoperative fluoroscopy and complications were reviewed. Postoperative radiograph and CT were conducted to assess the reduction quality. Fracture healing was evaluated by radiograph performed at each follow-up. Majeed score was recorded at the final follow-up to assess the functional outcome. Thirty-eight patients were included in group A and thirty-two patients in group B in this study. There was no significant difference in the demographic data of the two groups. A significant difference existed in the results for average operation time (P = .022) and blood loss (P = .000) between group A and group B. The mean frequency of intraoperative fluoroscopy was 15.82 in group A and 3.94 in group B (P = .000). All the fractures healed in this study. The rates of satisfactory reduction quality and functional outcome showed no significant difference between the two groups (P > .05). The complication rate was 15.79% (6/38) in group A and 9.38% (3/32) in group B (P = .660). Compared with anterior plating, percutaneous unilateral S1 sacroiliac screw usage is less invasive; however, more intraoperative X-ray exposure and permanent neurologic damage may accompany this procedure. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  3. Fixation of displaced subcapital femoral fractures. Compression screw fixation versus double divergent pins.

    Science.gov (United States)

    Christie, J; Howie, C R; Armour, P C

    1988-03-01

    One hundred and twenty-seven consecutive patients with displaced subcapital fractures of the femoral neck (Garden Grade III or IV) all under 80 years of age and independently mobile, were randomly allocated to fixation with either double divergent pins or a single sliding screw-plate device. The incidence of non-union and infection in the sliding screw-plate group was significantly higher, and we believe that when internal fixation is considered appropriate multiple pinning should be used. Mobility after treatment was disappointing in about half of the patients, and we feel that internal fixation can only be justified in patients who are physiologically well preserved and who maintain a high level of activity.

  4. Percutaneous Intramedullary Screw Fixation of Distal Fibula Fractures: A Case Series and Systematic Review.

    Science.gov (United States)

    Loukachov, Vladimir V; Birnie, Merel F N; Dingemans, Siem A; de Jong, Vincent M; Schepers, Tim

    The current reference standard for unstable ankle fractures is open reduction and internal fixation using a plate and lag screws. This approach requires extensive dissection and wound complications are not uncommon. The use of intramedullary screw fixation might overcome these issues. The aim of our study was to provide an overview of the published data regarding intramedullary screw fixation of fibula fractures combined with a small consecutive case series. We performed a search of published studies to identify the studies in which fibula fractures were treated with percutaneous intramedullary screw fixation. Additionally, all consecutive patients treated for an unstable ankle fracture in a level 1 trauma center using an intramedullary screw were retrospectively included. The literature search identified 6 studies with a total of 180 patients. Wound infection was seen in 1 patient (0.6%), anatomic reduction was achieved in 168 patients (93.3%), and a loss of reduction was seen in 2 patients (1.1%). Implant removal was deemed necessary in 3 patients (1.7%) and nonunion was seen is 2 patients (1.1%). A total of 11 patients, in whom no wound complications occurred, were included in our study. The follow-up duration was a minimum of 12 months. A secondary dislocation was seen in 1 patient, and delayed union was observed after 7.5 months in 1 other patient. In conclusion, intramedullary screw fixation is a safe and adequate method to use for fibula fractures, with a low risk of wound complications. Additional research regarding functional outcome is warranted. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Comparative endurance testing of the Biomet Matthews Nail and the Dynamic Compression Screw, in simulated condylar and supracondylar femoral fractures

    Directory of Open Access Journals (Sweden)

    Davies Benjamin M

    2008-01-01

    Full Text Available Abstract Background The dynamic compression screw is a plate and screws implant used to treat fractures of the distal femur. The Biomet Matthews Nail is a new retrograde intramedullary nail designed as an alternative surgical option to treat these fractures. The objective of this study was to assess the comparative endurance of both devices. Method The dynamic compression screw (DCS and Biomet Matthews Nail (BMN were implanted into composite femurs, which were subsequently cyclically loaded using a materials testing machine. Simulated fractures were applied to each femur prior to the application of load. Either a Y type fracture or a transverse osteotomy was prepared on each composite femur using a jig to enable consistent positioning of cuts. Results The Biomet Matthews Nail demonstrated a greater endurance limit load over the dynamic compression screw in both fracture configurations. Conclusion The distal locking screws pass through the Biomet Matthews Nail in a unique "cruciate" orientation. This allows for greater purchase in the bone of the femoral condyle and potentially improves the stability of the fracture fixation. As these fractures are usually in weak osteoporotic bone, the Biomet Matthews Nail represents a favourable surgical option in these patients.

  6. Comparative study of W-shaped angular plate and reconstruction plate in treating posterior wall fractures of the acetabulum.

    Directory of Open Access Journals (Sweden)

    Qi Zhang

    Full Text Available OBJECTIVE: This study aims to assess the medium-term results of the reconstruction of posterior wall fractures using a W-shaped acetabular angular plate (WAAP compared to those fixed using a reconstruction plate. METHODS: Between July 2006 and March 2009, we performed a retrospective study, which collected data for any patient treated for a posterior acetabular wall fracture. At the time of treatment, patients were either treated using a WAAP or a pelvic reconstruction plate. The intraoperative fluoroscopic images for both groups were compared. The quality of reduction and radiological grading were assessed according to the criteria developed by Matta. The clinical assessment was based on a modified Merle d'Aubigne and Postel scoring. RESULTS: 53 patients met the inclusion criteria and were followed up for an average of 38 months. 25 patients were treated with a WAAP (study group, and 28 patients were treated with a pelvic reconstruction plate (control group. The intraoperative fluoroscopic images of the study group confirmed extra-articular screw placement in all cases. In the control group, intra-articular screw placement was observed intraoperatively in 5 patients (17.86%, and the definitive location of the periarticular hardware could not be determined in 4 patients (14.29% during the operation. The differences between the two groups were statistically significant (p = 0.002. In contrast, the quality of fracture reduction, clinical outcomes, and radiological grading in the study group were not significantly different from those of the control group (p>0.05. The radiographic grade was strongly associated with the clinical outcomes in both the study and control groups (p<0.05. CONCLUSION: Reconstruction of posterior wall fractures of the acetabulum using a WAAP can help avoid screw penetration of the hip joint, provide a stable fixation of the posterior wall, and ensure good clinical outcomes.

  7. Intermaxillary Fixation Screw Morbidity in Treatment of Mandibular Fractures

    DEFF Research Database (Denmark)

    Florescu, Vlad-Andrei; Kofod, Thomas; Pinholt, Else Marie

    2016-01-01

    Purpose The aim of the present retrospective study was to investigate the morbidity of screws used for intermaxillary fixation (IMF) in the treatment of mandibular fractures. A review of the published data was also performed for a comparison of outcomes. Our hypothesis was that the use of screws...... for IMF of mandibular fractures would result in minimal morbidity. Materials and Methods Patients treated for mandibular fractures from 2007 to 2013, using screws for IMF, using the international diagnosis code for mandibular fracture, DS026, were anonymously selected (Department of Oral and Maxillofacial...... Surgery, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark). The fracture type, radiographic findings, treatment modality, screw type and number, and root damage were recorded. For the outcome comparison, a review of the published data regarding iatrogenic dental root damage caused...

  8. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System.

    Science.gov (United States)

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  9. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.

    Science.gov (United States)

    Kudo, Toshiya; Hara, Akira; Iwase, Hideaki; Ichihara, Satoshi; Nagao, Masashi; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-10-01

    Previous reports have questioned whether an orthogonal or parallel configuration is superior for distal humeral articular fractures. In previous clinical and biomechanical studies, implant failure of the posterolateral plate has been reported with orthogonal configurations; however, the reason for screw loosening in the posterolateral plate is unclear. The purpose of this study was to evaluate biomechanical properties and to clarify the causes of posterolateral plate loosening using a humeral fracture model under axial compression on the radial or ulnar column separately. And we changed only the plate set up: parallel or orthogonal. We used artificial bone to create an Association for the Study of Internal Fixation type 13-C2.3 intra-articular fracture model with a 1-cm supracondylar gap. We used an anatomically-preshaped distal humerus locking compression plate system (Synthes GmbH, Solothurn, Switzerland). Although this is originally an orthogonal plate system, we designed a mediolateral parallel configuration to use the contralateral medial plate instead of the posterolateral plate in the system. We calculated the stiffness of the radial and ulnar columns and anterior movement of the condylar fragment in the lateral view. The parallel configuration was superior to the orthogonal configuration regarding the stiffness of the radial column axial compression. There were significant differences between the two configurations regarding anterior movement of the capitellum during axial loading of the radial column. The posterolateral plate tended to bend anteriorly under axial compression compared with the medial or lateral plate. We believe that in the orthogonal configuration axial compression induced more anterior displacement of the capitellum than the trochlea, which eventually induced secondary fragment or screw dislocation on the posterolateral plate, or nonunion at the supracondylar level. In the parallel configuration, anterior movement of the capitellum or

  10. Fixing a fractured arthrodesed hip with rapid prototype templating and minimal invasive plate osteosynthesis

    Directory of Open Access Journals (Sweden)

    Christian Fang

    2015-12-01

    Full Text Available CASE:: We present an elderly lady with an intertrochanteric fracture of a previously fused hip. A 3D printed model of her pelvis and femur was used for implant templating before surgery. Minimal invasive fixation was performed with a spanning reversed distal femur locking plate without the need for removal of the previous implant. Multiple long locking screws were placed in the supra-acetabular region. The patient had union in 4 months, return to function and no complication. Conclusion:: The technique allowed us to optimize implant selection and insert screws safely at difficult trajectories using minimal invasive surgery. Keywords: Hip fusion, Fracture, Plating, Minimal invasive, 3D printing

  11. Treatment for proximal humeral fractures with percutaneous plating: our first results.

    Science.gov (United States)

    Imarisio, D; Trecci, A; Sabatini, L; Scagnelli, R

    2013-06-01

    Proximal humeral fractures are common lesions; there is no generally accepted strategy about the treatment for displaced and unstable two- to four-part fractures. We have nowadays many different surgical solutions, ranging from percutaneous pinning to shoulder arthroplasty. Percutaneous plating can be a good solution to treat some of these fractures using a minimally invasive technique and performing stable fixation that can allow early mobilization. Purpose of this paper is to evaluate the results of our first cases of percutaneous plating in proximal humeral fractures in order to assess the theoretical advantages and the incidence of possible complications. From June 2009 to February 2012, we treated 29 proximal humeral fractures with a percutaneous plating (NCB-PH plate) through an anterolateral deltoid split. For each patient, we evaluated the clinical outcome according to Constant score and the radiographic results, paying attention to fracture healing, loss of reduction, hardware complications, and head necrosis. The clinical evaluation gave a mean Constant score value of 79 points. Comparing each value to the unaffected shoulder, we could find these results: 7 excellent, 10 good, 8 fair, and 4 poor. No axillary nerve lesions were clinically detected. The radiographic evaluation showed a complete bone healing in all cases within the first 3 months. No head necrosis was detected, as well as screws loosening. In two cases, the X-ray at 2 months revealed a little loss of reduction in varus. Two patients had an anterior pain; in one of these two cases, the plate was removed. In our series, we had no cases of head necrosis, screws cutout, fracture collapse, hardware mobilization, and we think this could be the real advantage of the percutaneous technique compared to the open one, thanks to the reduced biological damage. We had some poor results, related more to patient's age than to other factors. The safety of the technique for the axillary nerve is

  12. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    Directory of Open Access Journals (Sweden)

    Bo Kyun Sim

    2017-01-01

    Full Text Available The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  13. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    Science.gov (United States)

    Kim, Bongju; Shin, Yoo Jin

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA. PMID:29065610

  14. Biomechanical comparison of double-row locking plates versus single- and double-row non-locking plates in a comminuted metacarpal fracture model.

    Science.gov (United States)

    Gajendran, Varun K; Szabo, Robert M; Myo, George K; Curtiss, Shane B

    2009-12-01

    Open or unstable metacarpal fractures frequently require open reduction and internal fixation. Locking plate technology has improved fixation of unstable fractures in certain settings. In this study, we hypothesized that there would be a difference in strength of fixation using double-row locking plates compared with single- and double-row non-locking plates in comminuted metacarpal fractures. We tested our hypothesis in a gap metacarpal fracture model simulating comminution using fourth-generation, biomechanical testing-grade composite sawbones. The metacarpals were divided into 6 groups of 15 bones each. Groups 1 and 4 were plated with a standard 6-hole, 2.3-mm plate in AO fashion. Groups 2 and 5 were plated with a 6-hole double-row 3-dimensional non-locking plate with bicortical screws aimed for convergence. Groups 3 and 6 were plated with a 6-hole double-row 3-dimensional locking plate with unicortical screws. The plated metacarpals were then tested to failure against cantilever apex dorsal bending (groups 1-3) and torsion (groups 4-6). The loads to failure in groups 1 to 3 were 198 +/- 18, 223 +/- 29, and 203 +/- 19 N, respectively. The torques to failure in groups 4 to 6 were 2,033 +/- 155, 3,190 +/- 235, and 3,161 +/- 268 N mm, respectively. Group 2 had the highest load to failure, whereas groups 5 and 6 shared the highest torques to failure (p row plates had equivalent bending and torsional stiffness, significantly higher than observed for the single-row non-locking plate. No other statistical differences were noted between groups. When subjected to the physiologically relevant forces of apex dorsal bending and torsion in a comminuted metacarpal fracture model, double-row 3-dimensional non-locking plates provided superior stability in bending and equivalent stability in torsion compared with double-row 3-dimensional locking plates, whereas single-row non-locking plates provided the least stability.

  15. [Internal screwed plate for recent fractures of the humeral diaphysis in adults].

    Science.gov (United States)

    Dayez, J

    1999-06-01

    Can medial plating of the humerus, through an antero lateral approach, diminish incidence of iatrogenic radial palsies? We carried out a prospective study of medial plating of humeral shaft fractures through an antero lateral approach between 1988 and 1997. 41 fractures were fixed, 36 were followed up for a mean period of 5.8 years. The indications were multiple injuries (10), displaced fractures (23), and failure of conservative treatment (3). Road traffic accidents and sports injuries were the cause in 68 per cent of cases. Two fractures were open and in 9 cases there was a radial palsy. Bone graft was never used. The approach to the medial aspect of the humerus an antero lateral incision was the essential feature of the technique. After a slightly curved incision on the antero lateral aspect of the arm, the space between biceps and brachialis anterior was bluntly dissected. The assistant holded the elbow flexed in order to relax the biceps and rotated il laterally to expose the medial aspect of the bone. Splitting brachialis fibres longitudinally exposed the fracture site. It was easy to check if the radial nerve was trapped and, if not, the nerve seen during the operation. Postoperatively patients were given a simple sling and mobilised freely, including rotation. We had no intra-operative complications, no infections, no fixation failure, no post operative radial palsies and no non-unions. Results were excellent in 89 per cent of cases (full recovery of pain free range of movement). Four patient had a restriction of elbow movements of 10 degrees but without any discomfort. The mean time to union was 80 days. All radial nerve palsies recovered between 24 hours and 1 year. The plate was removed in 11 cases. Iatrogenic complications of humeral plating have led to the increased popularity of intramedullary nailing. Even if secondary radial palsies and non-unions have decreased, union of the humeral shafts is often difficult. Placing the plate into the medial

  16. Application of biodegradable plates for treating pediatric mandibular fractures.

    Science.gov (United States)

    An, Jingang; Jia, Pengcheng; Zhang, Yi; Gong, Xi; Han, Xiaodong; He, Yang

    2015-05-01

    We assessed the clinical results of a biodegradable plate system for the internal fixation of mandibular fractures in children, and observed the imaging features of fracture healing and bone changes around the biodegradable plates and screws during follow-up. We enrolled 39 patients (22 male, 17 female, average age 4 years 10 months) with different mandibular fractures. We used 2.0-mm resorbable plates to repair the fractures. Postoperative follow-up ranged from 6 months to 5 years; average follow-up was 1 year 2 months. The outcome measures identified and assessed included facial symmetry, mouth opening, occlusal relationship, infection, nonunion, malunion, and plate dehiscence. We fixed 42 fractures with 43 resorbable plates; the fracture site of one patient (aged 11 years 3 months) was fixed with two plates. Two patients developed small fistulas at the intraoral incision 2 months after surgery; the fistulas healed after 1 month without special treatment. In the other patients, the incision healed well, there was facial symmetry, mouth opening was >35 mm, and occlusion was good. Follow-up computed tomography examination data were available for 20 cases, and revealed different degrees of radiolucency indicating that osteolysis had occurred. Radiolucency was observed around the resorbable plates 1 month after the surgery. The extent and depth of the radiolucent region were obvious within 1 year of surgery. In the second year, there were obvious repairs, with the bony defect areas becoming shallower. After 2 years, the bony defect areas had almost disappeared. Biodegradable fixation devices are safe and efficient for treating pediatric mandibular fractures. Osteolysis commonly follows biodegradable fixation of pediatric mandibular fractures, and has no adverse effect on fracture healing. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. [Fusion of reconstructed titanic plate, vertebral pedical screws and autogenous granulated cancellous bone graft in posterior occipitocervical region].

    Science.gov (United States)

    Zhong, Dejun; Song, Yueming

    2006-08-01

    To explore the technique of fusing the reconstructed titanic plate, the C2 pedical screws, and the autogenous granulated cancellous bone graft in the occipitocervical region. From April 2002 to January 2005, 19 patients aged 31-67 years with occipitocervical instability underwent the occipitocervical fusion using the reconstructed plate, C2 pedical screws, and autogenous granulated cancellous bone graft. Of the patients, 8 had complex occipitocervical deformity, 8 had old atlantoaxial fracture and dislocation, 2 had rheumatoid arthritis and anterior dislocation of the atlantoaxial joint, and 1 had cancer of the deltoid process of the axis. No complication occurred during and after operation. The follow-up for an average of 16 months in 19 patients showed that all the patients achieved solid bony fusion in the occipitocervical region. There was no broken plate, broken screw, looseness of the internal fixation or neurovascular injury. The fixation of the C2 pedical screws with the reconstructed titanic plate is reliable, the insertion is easy, and the autogenous granulated cancellous bone graft has a high fusion rate, thus resulting in a satisfactory effect in the occipitocervical fusion.

  18. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2017-07-01

    Full Text Available Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis with crossed-screwsor with a nonlocking plate with lag screw. Results: There were four non-unions in crossed-screws patients and one nonunion in non-locked plate group. All the patients in locking plate group achieved union. 90% of the patients were completely or mildly satisfied in locking plate group, whereas this rate was 80% for patients in both crossed screws and non-locking plate groups. Conclusions: Use of dorsal plating for arthrodesis of MTP1 joint either locking or non-locking were associated with high union rate and acceptable and comparable functional outcome. Although nonunion rate was high using two crossed screws but functional outcome was not significantly different compare to dorsal plating. Level of evidence:Ш, retrospective comparative study

  19. Correlation between classification and secondary screw penetration in proximal humeral fractures.

    Directory of Open Access Journals (Sweden)

    Qiuke Wang

    Full Text Available In this study, we investigated the correlation between fracture classification and secondary screw penetration.We retrospectively identified 189 patients with displaced proximal humeral fractures treated by ORIF at our hospital between June 2006 and June 2013. All fractures were classified radiographically before surgery and follow-up for least 2 years after surgery was recommended. At each follow-up, radiographs were taken in three orthogonal views to evaluate secondary screw penetration.The study population consisted of 189 patients. Of these, 70 were male and 119 female, with a mean age of 59.1 years; the mean follow-up time was 28.5 months. Secondary screw penetration occurred in 26 patients. The risk of developing secondary screw penetration was 11.3-fold higher in four-part fractures than two-part fractures (P 0.05.Patients with four-part fractures, type C fractures and medial hinges disruption are vulnerable to secondary screw penetration. This allows additional precautions to be instituted and measures to be taken as needed.

  20. Adolescent Volar Barton Fracture with Open Physis treated with Volar Plating using Buttressing Principle

    Directory of Open Access Journals (Sweden)

    Shah H

    2015-07-01

    Full Text Available Objective: The objective of the study was to assess the outcome of Salter- Harris type III distal radius fracture fixed using the principle of buttressing and avoiding screw insertion through the physis. Materials and Method: Eight school going children in the age group of 11-16 years with volar Barton fractures were treated with a volar plate using the buttress principle without inserting screws in the distal fragment. Patients were evaluated over a period of 18 months. Clinical evaluation was done using the Green O’Brien criteria and radiological evaluation using the Sarmiento criteria. Results: The average union time was two months. All the patients had good to excellent functional outcome with full extension and flexion. Conclusion: Buttress plating of volar Barton fractures in the adolescent age group is an excellent technique to achieve satisfactory outcome without violation of the physis.

  1. Surgical treatment of proximal humerus fractures using PHILOS plate

    Directory of Open Access Journals (Sweden)

    Vijay Sharma

    2014-10-01

    Full Text Available 【Abstract】Objective: To evaluate functional outcome and complications of open reduction and internal fixation with proximal humeral internal locking system (PHILOS plate for proximal humerus fractures. Methods: We reviewed 51 patients who underwent open reduction and internal fixation with PHILOS plate between the years 2007 to 2012. There were 35 men and 16 women with a mean age of 38 years (range 24-68. There were 41 patients in the age group of <60 years and 10 patients in the age group of >60 years. According to Neer classification system, 8, 15 and 23 patients had 2-part, 3-part, and 4-part fractures, respectively and 5 patients had 4-part fracture dislocation. All surgeries were carried out at our tertiary care trauma centre. Functional evaluation of the shoulder at final follow-up was done using Constant-Murley score. Results: The mean follow-up period was 30 months (range 12-44 months. Two patients were lost to followup. Of the remaining 49 patients, all fractures were united clinically and radiologically. The mean time for radiological union was 12 weeks (range 8-20 weeks. At the final follow-up the mean Constant-Murley score was 79 (range 50-100. The results were excellent in 25 patients, good in 13 patients, fair in 6 atients and poor in 5 patients. During the follow-up, four cases of varus malunion, one case of subacromial impingement, one case of deep infection, one case of intraarticular screw penetration and one case of failure of fi xation were noted. No cases of avascular necrosis, hardware failure, locking screw loosening or nonunion were noted. Conclusion: PHILOS provides stable fixation in proximal humerus fractures. To prevent potential complications like avascular necrosis, meticulous surgical dissection to preserve vascularity of humeral head is necessary. Key words: Proximal humerus fracture; Fracture fixation, internal; Proximal humeral internal locking system

  2. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    Directory of Open Access Journals (Sweden)

    Lokesh

    2016-05-01

    (22% 4 patients for which secondary surgery with bone grafting procedure was done after 4 months. According to AOFAS, 7 we scored the functional outcome of the patients after 5 months of injury. We had 23% of excellent result, 30.4% good and 46% fair with plate. CONCLUSION Locking anatomical plates are a boon and have started a new era in orthopaedic surgery in fixation with articular fractures. But due to lack of locking plate principle it is again cumbersome. Locking plates give relative stability for fracture and need as much as possible anatomical reduction of articular margins unlike in nail where we can do dynamisation if fracture going for delayed union in locking plates is not possible, hence doing as much as possible fracture alignment and then stabilising the fracture with screws is recommended.

  3. Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture

    OpenAIRE

    Wu, Ai-Min; Jin, Hai-Ming; Lin, Zhong-Ke; Chi, Yong-Long; Wang, Xiang-Yang

    2017-01-01

    Background The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Methods Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 trans...

  4. An alternative method in mandibular fracture treatment: bone graft use instead of a plate.

    Science.gov (United States)

    Alagöz, Murat Sahin; Uysal, Ahmet Cagri; Sensoz, Omer

    2008-03-01

    In the treatment of the mandibular fractures, one of the main principles is to use the least amount of foreign material. We present an alternative technique that the bone grafts harvested from the fracture borders or from the iliac crest were used instead of plates and the fixation was done with screws. In the study including 24 mandible fractures, the bone grafts harvested from the fracture borders were used in the 10 favorable fractures and the bone grafts harvested from the iliac crest were used in the 14 unfavorable fractures. In the combined mandible fractures, four fractures were fixated with titanium plates and the other side with the bone graft. The patients, who were followed up for 12 to 20 months, were evaluated with macroscopic occlusion, panoramic graphs, and three-dimensional computerized tomographs. The advantage of this technique of fixation with the autogenous tissue is reduced infection rates and reduced operation costs. In the pediatric patients, the second session operation of plate removal is not necessary.

  5. Dual head screw hip nailing for trochanteric fractures

    Science.gov (United States)

    Mavrogenis, Andreas F.; Igoumenou, Vasilios G.; Megaloikonomos, Panayiotis D.; Panagopoulos, George N.; Galanopoulos, Ioannis P.; Vottis, Christos Th.; Karamanis, Eirinaios; Koulouvaris, Panayiotis; Papagelopoulos, Panayiotis J.

    2017-01-01

    Introduction: There are limited information and inconclusive results for dual head screw intramedullary hip nails for trochanteric fractures. Therefore, we performed a prospective study to evaluate the healing of fractures, and survival, function, and complications of patients operated with this implant. Methods: We prospectively studied 79 patients (61 women and 18 men; mean age: 84.7 years; range: 65–96 years) with a low-energy trochanteric fracture, treated with a dual head screw intramedullary hip nail from 2013 to 2016. The mean follow-up was 2.1 years (range: 1–3 years); seven patients were lost to follow up. This left 72 patients for further analysis. We evaluated the healing of fractures, and survival, function, and complications of patients. Results: Fracture healing was evident in 70 patients (97.2%) at 2–3 months postoperatively. One patient experienced cut-out and z-effect phenomenon of the head screws. Another patient experienced a periprosthetic femoral diaphysis fracture at the distal tip of the nail. A third patient experienced an acute postoperative superficial skin infection that was treated successfully with wound dressing changes and a course of antibiotics. Sixteen patients (22.2%) deceased within 12 months postoperatively. In the remaining patients, the Harris Hip Score (HHS) at 12 months postoperatively was excellent in 16 (28.6%), good in 23 (41.1%), fair in 10 (17.8%), and poor in 7 patients (12.5%). The function declined after the patients’ fracture. Fair and poor results were related to age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types. Conclusion: The dual head screw intramedullary hip nail is associated with high healing and low complication rates for intertrochanteric fractures. The function of the patients is good or excellent in most cases; however, it declines, especially for those patients with age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types

  6. Dual head screw hip nailing for trochanteric fractures

    Directory of Open Access Journals (Sweden)

    Mavrogenis Andreas F.

    2017-01-01

    Full Text Available Introduction: There are limited information and inconclusive results for dual head screw intramedullary hip nails for trochanteric fractures. Therefore, we performed a prospective study to evaluate the healing of fractures, and survival, function, and complications of patients operated with this implant. Methods: We prospectively studied 79 patients (61 women and 18 men; mean age: 84.7 years; range: 65–96 years with a low-energy trochanteric fracture, treated with a dual head screw intramedullary hip nail from 2013 to 2016. The mean follow-up was 2.1 years (range: 1–3 years; seven patients were lost to follow up. This left 72 patients for further analysis. We evaluated the healing of fractures, and survival, function, and complications of patients. Results: Fracture healing was evident in 70 patients (97.2% at 2–3 months postoperatively. One patient experienced cut-out and z-effect phenomenon of the head screws. Another patient experienced a periprosthetic femoral diaphysis fracture at the distal tip of the nail. A third patient experienced an acute postoperative superficial skin infection that was treated successfully with wound dressing changes and a course of antibiotics. Sixteen patients (22.2% deceased within 12 months postoperatively. In the remaining patients, the Harris Hip Score (HHS at 12 months postoperatively was excellent in 16 (28.6%, good in 23 (41.1%, fair in 10 (17.8%, and poor in 7 patients (12.5%. The function declined after the patients’ fracture. Fair and poor results were related to age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types. Conclusion: The dual head screw intramedullary hip nail is associated with high healing and low complication rates for intertrochanteric fractures. The function of the patients is good or excellent in most cases; however, it declines, especially for those patients with age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3

  7. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  8. Comparison of circummandibular wiring with resorbable bone plates in pediatric mandibular fractures

    OpenAIRE

    Saikrishna, D.; Gupta, Nimish

    2010-01-01

    Pediatric patients present a unique challenge to maxillofacial surgeons in terms of their treatment planning as well as in their functional and nutritional needs which are different from that of adult patients. Early literature has advocated conservative closed management of pediatric fractures to prevent complications. However recent advances in maxillofacial surgery has enabled us to use biodegradable plates and screws, which overcomes the limitations of metallic plates. We present a compar...

  9. Comparative evaluation of 2.3 mm locking plate system vs conventional 2.0 mm non locking plate system for mandibular condyle fracture fixation: a seven year retrospective study.

    Science.gov (United States)

    Zhang, J; Wang, X; Wu, R-H; Zhuang, Q-W; Gu, Q P; Meng, J

    2015-01-01

    This retrospective study evaluated the efficacy of a 2.3 mm locking plate/screw system compared with a 2.0-mm non-locking plate/screw system in fixation of isolated non comminuted mandibular condyle fractures. Surgical records of 101 patients who received either a 2.3 mm locking plate (group A, n = 51) or 2.0 mm non locking plate (group B, n = 50) were analyzed. All patients were followed up to a minimum of 6 months postoperatively and evaluated for hardware related complications, occlusal stability, need for and duration of MMF and mandibular functional results. Four complications occurred in the locking group and eighteen in the non locking group with complication rates equalling 8% and 36% respectively. When comparing the overall results according to plates used, the χ2 test showed a statistically significant difference between the locking and non locking plates (p Mandibular condyle fractures treated with a 2.3 mm locking plate exhibited stable osteosynthesis, were associated with minimal complications and resulted in acceptable mandibular range of motion compared with a 2.0 mm non locking plate.

  10. Surgical repair of skull fractures in four horses using cuttable bone plates.

    Science.gov (United States)

    Dowling, B A; Dart, A J; Trope, G

    2001-05-01

    Three horses with severely comminuted, open facial bone fractures and one horse with a comminuted, open orbital rim fracture were referred for treatment. Severe facial bone asymmetry and epistaxis were apparent in all cases and subcutaneous emphysema was present in two, however physical and neurological examinations were otherwise normal. Radiography and endoscopy were of some use in assessing the degree of damage, although the true extent of the damage was more apparent at surgery. Surgical reduction of the fractures was recommended to maximise cosmetic and functional outcome. After surgical debridement and reduction of the fractures the bone fragments remained unstable and were not amenable to stabilisation with interfragmentary wires alone, so 2 mm cuttable bone plates were used to maintain fracture alignment. Screw migration occurred in three horses and in one of these horses the plate had to be removed. Other complications were minor and in all horses the fractures healed with good cosmetic and functional outcome. The use of cuttable bone plates should be considered as a reasonable alternative to inter-fragmentary wiring for unstable, comminuted fractures of the facial bones, even where fractures are open.

  11. The effect of inferomedial screw on postoperative shoulder function and mechanical alignment in proximal humerus fractures.

    Science.gov (United States)

    Erdoğan, Murat; Desteli, Engin Eren; İmren, Yunus; Üztürk, Ali; Kılıç, Mesut; Sezgin, Hicabi

    2014-10-01

    The aim of the study was to evaluate the clinical and radiologic results of locking plate fixation with or without inferomedial screw (IMS) in surgically treated proximal humerus fractures. Thirty-six patients with displaced proximal humerus fractures from two centers were operated using locking plate. All of the fractures were classified according to the Neer classification. In 18 of the cases, an additional IMS running through the medial curvature of the surgical neck was used. There was no significant difference among both groups in terms of height, gender, weight, and mechanism of injury. The fractures were evaluated according to the radiographic and functional findings during follow-up period of 14 months in average (range 8-32 months). At the end of first year, shoulder radiographs were received and shoulder examinations were performed using ASES scores. Humeral head-shaft angles were measured by true AP projections. Head-shaft angle measurements were categorized as varus if 145. Mean time for fracture healing was 18 weeks. Complete union was achieved in 35 patients by the end of 6 months. In one of the 18 displaced proximal humerus fractures of IMS (+) group, the head-shaft angle was measured to be <125, whereas six patients had varus deviation in IMS (-) group at follow-up (p < 0.05). Mean ASES scores of IMS (+) group and IMS (-) group were 58.21 ± 5.82 and 38.61 ± 3.44, respectively (p < 0.001). Use of inferomedial screw running through the medial curvature of surgical neck prevents varus deformity and improves functional outcome after surgical treatment for proximal humerus fractures.

  12. Aspects of internal fixation of fractures in porotic bone. Principles, technologies and procedures using locked plate screws.

    Science.gov (United States)

    Perren, S M; Linke, B; Schwieger, K; Wahl, D; Schneider, E

    2005-01-01

    Fractures of the bones of elderly people occur more often and have a more important effect because of a generally diminished ability to coordinate stance and walking. These fractures occur at a lower level of load because of lack of strength of the porotic bone. Prompt recovery of skeletal support function is essential to avoid respiratory and circulatory complications in the elderly. To prevent elderly people from the risks of being bedridden, demanding internal fixation of fractures is required. The weak porotic bone and the high level of uncontrolled loading after internal fixation pose complex problems. A combination of several technical elements of design, application and aftercare in internal fixation are proposed. Internal fixators with locked screws improve the biology and the mechanics of internal fixation. When such fixators are used as elevated splints they may stimulate early callus formation because of their flexibility, the limit of flexibility being set by the demands of resistance and function of the limb. Our own studies of triangulation of locked screws have demonstrated their beneficial effects and unexpected limitations.

  13. A biomechanical comparison of four fixed-angle dorsal plates in a finite element model of dorsally-unstable radius fracture.

    Science.gov (United States)

    Knežević, Josip; Kodvanj, Janoš; Čukelj, Fabijan; Pamuković, Frane; Pavić, Arsen

    2017-11-01

    To compare the finite element models of two different composite radius fracture patterns, reduced and stabilised with four different fixed-angle dorsal plates during axial, dorsal and volar loading conditions. Eight different plastic models representing four AO/ASIF type 23-A3 distal radius fractures and four AO/ASIF 23-C2 distal radius fractures were obtained and fixed each with 1 of 4 methods: a standard dorsal non-anatomical fixed angle T-plate (3.5mm Dorsal T-plate, Synthes), anatomical fixed-angle double plates (2.4mm LCP Dorsal Distal Radius, Synthes), anatomical fixed angle T-plate (2.4mm Acu-Loc Dorsal Plate, Acumed) or anatomical variable-angle dorsal T-plate (3.5mm, Dorsal Plate, Zrinski). Composite radius with plate and screws were scanned with a 3D optical scanner and later processed in Abaqus Software to generate the finite element model. All models were axially loaded at 3 points (centrally, volarly and dorsally) with 50 N forces to avoid the appearance of plastic deformations of the models. Total displacements at the end of the bone and the stresses in the bones and plates were determined and compared. Maximal von Mises stress in bone for 3-part fracture models was very similar to that in 2-part fracture models. The biggest difference between models and the largest displacements were seen during volar loading. The stresses in all models were the highest above the fracture gap. The best performance in all parameters tested was with the Zrinski plate and the most modest results were with the Synthes T-plate. There was no significant difference between 2-part (AO/ASIF type 23-A3) and 3-part (AO/ASIF 23-C2) fracture models. Maximal stresses in the plates appeared above the fracture gap; therefore, it is worth considering the development of plates without screw holes above the gap. © 2017 Elsevier Ltd. All rights reserved.

  14. Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?

    Science.gov (United States)

    Lenz, Mark; Stoffel, Karl; Kielstein, Heike; Mayo, Keith; Hofmann, Gunther O; Gueorguiev, Boyko

    2016-12-01

    Proximal plate fixation in periprosthetic femur fractures can be improved by plate anchorage in the greater trochanter (lateral tension band principle) or bicortical locking screw placement beside the prosthesis stem in an embracement configuration. Both concepts were compared in a biomechanical test using a femoral hook plate (hook) or a locking attachment plate (LAP). After bone mineral density (BMD) measurement in the greater trochanter, six pairs of fresh frozen human femora were assigned to two groups and instrumented with cemented hip endoprostheses. A transverse osteotomy was set distal to the tip of the prosthesis, simulating a Vancouver B1 fracture. Each pair was instrumented using a plate tensioner with either hook or LAP construct. Cyclic testing (2Hz) with physiologic profile and monotonically increasing load was performed until catastrophic failure. Plate stiffness was compared in a four-point-bending-test. Paired student's-t-test was used for statistical evaluation (pTrochanteric fixation is highly BMD dependent and may be restricted to major greater trochanteric involvement requiring stabilization. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. FUNCTIONAL OUTCOME OF SUPRACONDYLAR FRACTURES OF FEMUR MANAGED BY OPEN REDUCTION AND INTERNAL FIXATION WITH LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    Madhusudhana

    2015-10-01

    Full Text Available INTRODUCTION : Incidence of distal femur fractures is approximately 37 per 1 , 00,000 person - years.¹Distal femoral fractures has two different injury mechanisms, high energy trauma and low energy trauma. In high - energy trauma, the problem of restoring the function in a destroyed knee joint persists. Complex knee ligament injuries frequently occur additionally to extensive cartilage injuries. In elderly patients, extreme osteoporosis represents a particular problem for anchoring the implant. 2 Supracondylar and inter condylar fractures often are unstable and comminuted and tend to occur in the elderly or those with multiple injuries. Treatment options are many with varied results. The final outcome would depend upon the type of fracture, stabilization of fixation and and perhaps patient general condition. 3 The options for operative treatment are traditional plating techniques that require compression of the implant to the femoral shaft (blade plate, Dynamic Condylar Screw, non - locking condylar buttress plate, antegrade nailing fixation, retrograde nailing, sub muscular locked internal fixation and external fixation. 4 However, as the complexity of fractures needing treatment has changed from simple extra - articular supra - condylar types to inter - condylar and metaphyseal comminuted types, these implants may not be ideal. Double plating, and more recently, locked plating techniques have been advocated 5 . However with double plating there is often extensive soft tissue stripping on both sides of the femur, resulting in reduced blood supply and potential non - union and failure of the implants 6 . The LCP is a single beam construct where the strength of its fixation is equal to the sum of all screw - bone interfaces rather than a single screw’s axial stiffness or pullout resistance as seen in unlocked plates 7,8 . Its unique biomechanical function is based on splinting rather than compression resulting in flexible stabilization

  16. Functional Recovery Following Pertrochanteric Hip Fractures Fixated with the Dynamic Hip Screw vs. the Percutaneous Compression Plate

    Directory of Open Access Journals (Sweden)

    Yocheved Laufer

    2005-01-01

    Full Text Available The Dynamic Hip Screw (DHS is currently the most frequently used implant for the treatment of pertrochanteric hip fractures. The Percutaneous Compression Plate (PCCP is a recently developed, alternative device that involves minimal invasive surgery. The objective of the present study was to compare functional recovery following these two surgical procedures. A total of 76 consecutive elderly subjects (mean age and standard deviation, 80.6 ± 5.5 following pertrochanteric hip fracture fixation were evaluated prospectively. Functional recovery was assessed 3 and 12 weeks and 2 years following surgery. Differences between groups 3 weeks postsurgery were found only in pain level during ambulation and in the weight-bearing capability of the operated extremity, which were both in favor of the PCCP. By 3 months, both groups had improved in all measures, but did not reach their preinjury level of independence. However, the PCCP group ambulated with fewer assistive devices and demonstrated better recovery of basic activities of daily living (BADL. While the majority of the subjects from both groups ambulated independently 2 years postsurgery, the PCCP group exhibited less pain during ambulation, was more independent in ADL, and required fewer assistive devices for ambulation. To summarize, the PCCP presents enhanced short- and long-term recovery of functional abilities in comparison to DHS. However, given the limited number of patients, further studies are necessary to substantiate these results.

  17. External fixation using locking plate in distal tibial fracture: a finite element analysis.

    Science.gov (United States)

    Zhang, Jingwei; Ebraheim, Nabil; Li, Ming; He, Xianfeng; Schwind, Joshua; Liu, Jiayong; Zhu, Limei

    2015-08-01

    External fixation of tibial fractures using a locking plate has been reported with favorable results in some selected patients. However, the stability of external plate fixation in this fracture pattern has not been previously demonstrated. We investigated the stability of external plate fixation with different plate-bone distances. In this study, the computational processing model of external fixation of a distal tibial metaphyseal fracture utilizing the contralateral femoral less invasive stabilization system plate was analyzed. The plate was placed on the anteromedial aspect of tibia with different plate-bone distances: 1, 10, 20, and 30 mm. Under axial load, the stiffness of construct in all groups was higher than intact tibia. Under axial load with an internal rotational force, the stiffness of construct with 1 and 10 mm plate-bone distances was similar to that of an intact tibia and the stiffness of the construct with 20 and 30 mm distances was lower than that of an intact tibia. Under axial load with an external rotational force, the stiffness of the construct in all groups was lower than that of an intact tibia. The maximum plate stresses were concentrated at the two most distal screws and were highest in the construct with the 10 mm plate-bone distance, and least in the construct with a 1 mm plate-bone distance. To guarantee a stable external plate fixation in distal tibial fracture, the plate-bone distance should be less than 30 mm.

  18. Displaced proximal humeral fractures: an Indian experience with locking plates

    Directory of Open Access Journals (Sweden)

    Aggarwal Sameer

    2010-08-01

    Full Text Available Abstract Background The treatment of displaced proximal humerus fractures, especially in elderly, remains controversial. The objective of this study was to evaluate functional outcome of locking plate used for fixation of these fractures after open reduction. We also attempted to evaluate the complications and predictors of loss of fixation for such an implant. Methods Over two and a half years, 56 patients with an acute proximal humerus fracture were managed with locking plate osteosynthesis. 47 of these patients who completed a minimum follow up of 1 year were evaluated using Constant score calculation. Statistical analysis was done using SPSS 16 and a p value of less than 0.05 was taken as statistically significant. Results The average follow up period was around 21.5 months. Outcomes were excellent in 17%, good in 38.5%, moderate in 34% while poor in 10.5%. The Constant score was poorer for AO-OTA type 3 fractures as compared to other types. The scores were also inferior for older patients (> 65 years old. Complications included screw perforation of head, AVN, subacromial impingement, loss of fixation, axillary nerve palsy and infection. A varus malalignment was found to be a strong predictor of loss of fixation. Conclusion Locking plate osteosynthesis leads to satisfactory functional outcomes in all the patients. Results are better than non locking plates in osteoporotic fractures of the elderly. However the surgery has steep learning curve and various complications could be associated with its use. Nevertheless we believe that a strict adherence to the principles of locking plate use can ensure good result in such challenging fractures.

  19. Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial Fractures

    Directory of Open Access Journals (Sweden)

    Hong Bae Jeon

    2016-01-01

    Full Text Available BackgroundBioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered eight cases of a delayed foreign body reaction after surgical fixation with bioabsorbable plates and screws.MethodsA total of 234 patients with a maxillofacial fracture underwent surgical treatment from March 2006 to October 2013, in which rigid fixation was achieved with the Inion CPS (Inion, Tampere, Finland plating system in 173 patients and Rapidsorb (Synthes, West Chester, PA, USA in 61 patients. Their mean age was 35.2 years (range, 15-84 years. Most patients were stabilized with two- or three-point fixation at the frontozygomatic suture, infraorbital rim, and anterior wall of the maxilla.ResultsComplications occurred in eight (3.4% of 234 patients, including palpable, fixed masses in six patients and focal swelling in two patients. The period from surgical fixation to the onset of symptoms was 9-23 months. Six patients with a mass underwent secondary surgery for mass removal. The masses contained fibrous tissue with a yellow, grainy, cloudy fluid and remnants of an incompletely degraded bioabsorbable plate and screws. Their histological findings demonstrated a foreign body reaction.ConclusionsInadequate degradation of bioabsorbable plates caused a delayed inflammatory foreign body reaction requiring secondary surgery. Therefore, it is prudent to consider the possibility of delayed complications when using bioabsorbable plates and surgeons must conduct longer and closer follow-up observations.

  20. Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation

    International Nuclear Information System (INIS)

    Jacob, Augustinus Ludwig; Messmer, Peter; Stock, Klaus-Wilhelm; Suhm, Norbert; Baumann, Bernard; Regazzoni, Pietro; Steinbrich, Wolfgang

    1997-01-01

    Purpose. To assess the midterm results of closed reduction and percutaneous fixation (CRPF) with computed tomography (CT)-guided sacroiliac screw fixation in longitudinal posterior pelvic ring fractures. Methods. Thirteen patients with 15 fractures were treated. Eleven patients received a unilateral, two a bilateral, screw fixation. Twenty-seven screws were implanted. Continuous on-table traction was used in six cases. Mean radiological follow-up was 13 months. Results. Twenty-five (93%) screws were placed correctly. There was no impingement of screws on neurovascular structures. Union occurred in 12 (80%), delayed union in 2 (13%), and nonunion in 1 of 15 (7%) fractures. There was one screw breakage and two axial dislocations. Conclusion. Sacroiliac CRPF of longitudinal fractures of the posterior pelvic ring is technically simple, minimally invasive, well localized, and stable. It should be done by an interventional/surgical team. CT is an excellent guiding modality. Closed reduction may be a problem and succeeds best when performed as early as possible

  1. Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

    Directory of Open Access Journals (Sweden)

    Jesse Chieh-Szu Yang

    Full Text Available Fixation with a dynamic hip screw (DHS is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw' to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03. Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12. However, the patient's implanted with a DHS did display significantly greater migration (P<0.001 than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.

  2. Clinical use of AO three-dimensionally preformed titanium mesh plates for orbital fractures

    Directory of Open Access Journals (Sweden)

    Ming Chen

    2015-01-01

    Full Text Available AIM:To evaluate the accuracy and practicability of three-dimensionally preformed Arbeitsgemeinschaft Osteosynthese AO titanium mesh plates for orbital fractures.METHODS:Forty-seven patients with isolated blow-out orbital fractures were included in this study. Fracture locations were as follows: floor/medial wall(n=26, 55%, medial wall(n=12, 26%, and floor(n=9, 19%. The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures with temporary dissection of inferior oblique muscle. A three-dimensionally preformed AO titanium mesh plate was selected according to the size of the defect previously measured on the preoperative computed tomographic scan examination and fixed at the inferior orbital rim with 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative computed tomography(CTscan. The practicability of clinical use of AO three-dimensionally preformed titanium mesh plates was assessed on the preoperative and postoperative clinical data.RESULTS: Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. All patients had a successful treatment outcome without clinical complications. 40 patients(87%had a successful enophthalmos correction. 25 patients(86%had a successful recovery from diplopia.CONCLUSION: Three-dimensionally preformed AO titanium mesh plates for orbital fracture reconstruction results in an accurate anatomic restoration of the bony orbital contour with a high rate of success to correctenophthalmos and diplopia.

  3. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone

    Directory of Open Access Journals (Sweden)

    Eduardo Aloisio Fleck NEUMANN

    2014-08-01

    Full Text Available Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface assembly. UCLA-type abutments were fixed to implants using titanium screws (Group 1, polyetheretherketone (PEEK screws (Group 2, and 30% carbon fiber-reinforced PEEK screws (Group 3. The assemblies were placed on a stainless steel holding apparatus to allow for loading at 45o off-axis, in a universal testing machine. A 200 N load (static load was applied at the central point of the abutment extremity, at a crosshead speed of 5 mm/minute, until failure. Data was analyzed by ANOVA and Tukey’s range test. The titanium screws had higher fracture resistance, compared with PEEK and 30% carbon fiber-reinforced PEEK screws (p 0.05. Finally, visual analysis of the fractions revealed that 100% of them occurred at the neck of the abutment screw, suggesting that this is the weakest point of this unit. PEEK abutment screws have lower fracture resistance, in comparison with titanium abutment screws.

  4. Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone.

    Science.gov (United States)

    Neumann, Eduardo Aloisio Fleck; Villar, Cristina Cunha; França, Fabiana Mantovani Gomes

    2014-01-01

    Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK) and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface assembly. UCLA-type abutments were fixed to implants using titanium screws (Group 1), polyetheretherketone (PEEK) screws (Group 2), and 30% carbon fiber-reinforced PEEK screws (Group 3). The assemblies were placed on a stainless steel holding apparatus to allow for loading at 45o off-axis, in a universal testing machine. A 200 N load (static load) was applied at the central point of the abutment extremity, at a crosshead speed of 5 mm/minute, until failure. Data was analyzed by ANOVA and Tukey's range test. The titanium screws had higher fracture resistance, compared with PEEK and 30% carbon fiber-reinforced PEEK screws (p 0.05). Finally, visual analysis of the fractions revealed that 100% of them occurred at the neck of the abutment screw, suggesting that this is the weakest point of this unit. PEEK abutment screws have lower fracture resistance, in comparison with titanium abutment screws.

  5. Surgical management of proximal splint bone fractures in the horse

    International Nuclear Information System (INIS)

    Peterson, P.R.; Pascoe, J.R.; Wheat, J.D.

    1987-01-01

    Fractures of Metacarpal and Metatarsal II and IV (the splint bones) were treated in 283 horses over an 11 year period. In 21 cases the proximal portion of the fractured bone was stabilized with metallic implants. One or more cortical bone screws were used in 11 horses, and bone plates were applied in 11 horses. One horse received both treatments. Complications of screw fixation included bone failure, implant failure, radiographic lucency around the screws, and proliferative new bone at the ostectomy site. Only two of the horses treated with screw fixation returned to their intended use. Complications of plate fixation included partial fixation failure (backing out of screws), wound drainage, and proliferative bony response around the plate. Six of the 11 horses treated by plate fixation returned to their intended use. The authors recommend consideration of plate fixation techniques for repair of fractures in the proximal third of the splint bone

  6. Supraglenoid tubercle fractures repair with transverse locking compression plates in 4 horses.

    Science.gov (United States)

    Ahern, B J; Bayliss, I P M; Zedler, S T; Getman, L M; Richardson, D W

    2017-05-01

    To report on a series of 4 horses with supraglenoid tubercle fractures repaired with locking compression plates. Case series. Four horses ranging in age from 6 weeks to 20 months and weighing from 121 to 425 kg with supraglenoid tubercle fractures of 1 day to 6 weeks in duration. Supraglenoid tubercle fractures were reduced and stabilized with transversely positioned locking compression plate(s) with and without additional tension band wiring. All fractures reached bony union. Two postoperative surgical site infections were managed with drainage and antibiotherapy. Three of the 4 horses continued onto athletic careers including flat racing, dressage, and hunter/jumper competition. The remaining horse was lame for a prolonged period, but was sound at 4 years. The application of one or two, transversely positioned LCPs should be considered for the repair of SGT fractures because of the relative ease of the technique, and its elimination of a biceps brachii tenotomy. All screws can be inserted in a lateral to medial direction without transection or drill penetration of the biceps brachii tendon. SGT fractures of various durations can be repaired in a wide range of horses with transversely positioned LCPs, and allow return to athletic function. © 2017 The American College of Veterinary Surgeons.

  7. Ipsilateral proximal femur and shaft fractures treated with hip screws and a reamed retrograde intramedullary nail.

    Science.gov (United States)

    Ostrum, Robert F; Tornetta, Paul; Watson, J Tracy; Christiano, Anthony; Vafek, Emily

    2014-09-01

    Although not common, proximal femoral fractures associated with ipsilateral shaft fractures present a difficult management problem. A variety of surgical options have been employed with varying results. We investigated the use of hip screws and a reamed retrograde intramedullary (IM) nail for the treatment of this combined fracture pattern in terms of postoperative alignment (malunion), nonunion, and complications. Between May 2002 and October 2011, a total of 95 proximal femoral fractures with associated shaft fractures were treated at three participating Level 1 trauma centers; all were treated with hip screw fixation (cannulated screws or sliding hip screws) and retrograde reamed IM nails. The medical records of these patients were reviewed retrospectively for alignment, malunion, nonunion, and complications. Followup was available on 92 of 95 (97%) of the patients treated with hip screws and a retrograde nail. Forty were treated with a sliding hip screw, and 52 were treated with cannulated screws. There were five proximal malunions in this series (5%). The union rate was 98% (90 of 92) for the femoral neck fractures and 91.3% (84 of 92) for the femoral shaft fractures after the initial surgery. There were two nonunions of comminuted femoral neck fractures after cannulated screw fixation. There was no difference in femoral neck union or alignment when comparing cannulated screws to a sliding hip screw. Four open comminuted femoral shaft fractures went on to nonunion and required secondary surgery to obtain union, and one patient developed symptomatic avascular necrosis. The treatment of ipsilateral proximal femoral neck and shaft fractures with hip screw fixation and a reamed retrograde nail demonstrated a high likelihood of union for the femoral neck fractures and a low risk of malunion. Comminution and initial displacement of the proximal femoral fracture may still lead to a small incidence of malunion or nonunion, and open comminuted femoral shaft fractures

  8. Treatment of proximal humerus fractures with locking plates: a systematic review.

    Science.gov (United States)

    Thanasas, Christos; Kontakis, George; Angoules, Antonios; Limb, David; Giannoudis, Peter

    2009-01-01

    Locking plates with special configuration for the anatomic region of the proximal humerus have been introduced recently to address the difficulties of stabilizing proximal humeral fractures. The purpose of this study was to carry out a systematic review of the literature on the efficacy and early to medium term functional results of locking plates for stabilization of proximal humeral fractures. Using the PubMed database, a systematic review of the English and German literature was carried out in order to assess the efficacy and complications related to the use of these plates and the patients' functional outcome, using the key words "locking plates proximal humeral fractures," "angular stability plates proximal humeral fractures," "PHILOS plate," and "LPHP plate." Our criteria for eligibility were clinical studies with more than ten cases followed-up, adult patients, and adequate data provided at least in terms of implant related complications. Articles written in English and German language were included. Exclusion criteria were: studies dealing exclusively with 2-part fractures (since this category has a more favorable outcome); experimental studies; case reports; and, literature other than English or German. Each one of the articles was evaluated for quality of the study using the Structured Effectiveness Quality Evaluation Scale (SEQES). Twelve studies including 791 patients met the inclusion criteria. Patients in these studies continued to improve up to one year, achieving a mean Constant score of 74.3. The incidence of the reported complications was: avascular necrosis 7.9%, screw cut-out 11.6% and re-operation rate 13.7%. The high incidence of cut-out may be secondary to the rigidity of the implant in combination with medial inadequate support, in cases compromised by severe underlying osteoporotic bone. Definition of indications for the use of locking plates and attention on technical aspects of applying them would help optimization of the results

  9. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison.

    Science.gov (United States)

    Mandell, Daniel; Karbassi, John; Zhou, Hanbing; Burroughs, Brian; Aurigemma, Philip; Patel, Abhay R

    2018-03-01

    The treatment of end-stage first metatarso-phalangeal joint (MTP) arthritis has been arthrodesis. A dorsal non-locking plate with a lag screw has been the standard traditional fixation method. This study compares the biomechanical strength of a locking compression plate (LCP) with and without internal compression versus this known gold standard. In group 1, six matched pairs of cadaver great toes were used to compare the standard non-locking dorsal plate and 3.5mm lag screw to an anatomic locking compression plate in which a lag screw was utilized rather than the internal compression features of the plate. In group 2, another six matched pairs of cadaver great toes were used to compare the gold standard to the locking compression plate, utilizing the plate's internal compression feature instead of a lag screw. A material testing system (MTS) machine applied loads to the MTP joints and measured displacement and stiffness of the constructs. The stiffness of the constructs (Young's modulus) was calculated from the force-displacement curves, and the displacement was measured. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control (p<0.05). The same plating construct in which a lag screw was used rather than internal compression of the plate was found to be stiffer than the control (p<0.05), but displacement was not statistically significant. The results suggest that a locking compression plate alone provides the stiffest construct for a first MTP joint fusion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Bone properties of the humeral head and resistance to screw cutout

    DEFF Research Database (Denmark)

    Frich, L. H.; Jensen, N. C.

    2014-01-01

    Surgical treatment of fractures involving the proximal humeral head is hampered by complications. Screw cutout is the major pitfall seen in connection with rigid plating. We have exploited a bony explanation for this phenomenon. Materials and Methods: We examined the convex surface of the humeral...... sectioning technique. Results: The bone strength and bone density correlated well and revealed large regional variations across the humeral head. Bone strength and stiffness of the trabecular bone came to a maximum in the most medial anterior and central parts of the humeral head, where strong textural...... screw directions will predictably place screws in areas of the humeral head comprising low density and low strength cancellous bone. New concepts of plates and plating techniques for the surgical treatment of complex fractures of the proximal humerus should take bone distribution, strength...

  11. Stress analysis of implant-bone fixation at different fracture angle

    Science.gov (United States)

    Izzawati, B.; Daud, R.; Afendi, M.; Majid, MS Abdul; Zain, N. A. M.; Bajuri, Y.

    2017-10-01

    Internal fixation is a mechanism purposed to maintain and protect the reduction of a fracture. Understanding of the fixation stability is necessary to determine parameters influence the mechanical stability and the risk of implant failure. A static structural analysis on a bone fracture fixation was developed to simulate and analyse the biomechanics of a diaphysis shaft fracture with a compression plate and conventional screws. This study aims to determine a critical area of the implant to be fractured based on different implant material and angle of fracture (i.e. 0°, 30° and 45°). Several factors were shown to influence stability to implant after surgical. The stainless steel, (S. S) and Titanium, (Ti) screws experienced the highest stress at 30° fracture angle. The fracture angle had a most significant effect on the conventional screw as compared to the compression plate. The stress was significantly higher in S.S material as compared to Ti material, with concentrated on the 4th screw for all range of fracture angle. It was also noted that the screws closest to the intense concentration stress areas on the compression plate experienced increasing amounts of stress. The highest was observed at the screw thread-head junction.

  12. Ordinary Cannulated Compression Screws or Headless Cannulated Compression Screws? A Synthetic Bone Biomechanical Research in the Internal Fixation of Vertical Femoral Neck Fracture

    Directory of Open Access Journals (Sweden)

    Baokun Zhang

    2018-01-01

    Full Text Available Purpose. The purpose of this study is to verify whether the headless cannulated compression screw (HCCS has higher biomechanical stability than the ordinary cannulated compression screw (OCCS in the treatment of vertical femoral neck fractures. Materials and Methods. 30 synthetic femur models were equally divided into 2 groups, with 50°, 60°, and 70° Pauwels angle of femoral neck fracture, under 3D printed guiding plates and C-arm fluoroscopic guidance. The femur molds were fixed with three parallel OCCSs as OCCS group and three parallel HCCSs as HCCS group. All specimens were tested for compressive strength and maximum load to failure with a loading rate of 2 mm/min. Results. The result showed that there was no significant difference with the compressive strength in the Pauwels angle of 50° and 60°. However, we observed that the maximum load to failure with the Pauwels angle of 50°, 60°, and 70° and the compressive strength with 70° of HCCS group showed better performance than the OCCS group. Conclusion. HCCS performs with better biomechanical stability than OCCS in the treatment of vertical femoral neck fracture, especially with the Pauwels angle of 70°.

  13. Locking compression plate osteosynthesis of complicated mandibular fractures in six horses.

    Science.gov (United States)

    Kuemmerle, J M; Kummer, M; Auer, J A; Nitzl, D; Fürst, A E

    2009-01-01

    Complicated mandibular fractures were recognised in one foal, one pony and four horses. The foal was two months old while the adult animals ranged in age from 12 to 24 years. Three horses had a unilateral horizontal ramus fracture. Two fractures were open and one was closed. Comminution was present in one of these patients while the other two horses had marked displacement of the fragments. Two suffered from comminuted fractures of the horizontal and vertical ramus of the mandible. One of these patients had open and infected fractures. One foal had a bilateral horizontal ramus fracture with marked periosteal 'new bone' formation and malalignement which required corrective osteotomy. Each horse underwent locking compression plate (LCP) osteosynthesis consisting of open fracture reduction and application of one to three 4.5/5.0 mm LCP at the ventral, lateral or caudal aspect of the mandible under fluoroscopic control. Two 3.5 mm LCP were used in the foal. Plate fixation was supported by application of a cerclage wire construct between the incisor and premolar teeth in most patients. Complete fracture healing, with an excellent functional and cosmetic outcome, was achieved in all of the patients. Complications encountered included seroma formation, screw and wire breakage, as well as implant and apical tooth root infections. The LCP was removed after fracture healing had occurred in four patients.

  14. [SCREW-BASED INTERMAXILLARY TRACTION COMBINED WITH OCCLUSAL SPLINT FOR TREATMENT OF PEDIATRIC MANDIBULAR CONDYLAR FRACTURE].

    Science.gov (United States)

    Wu, Yang; Long, Xing; Deng, Mohong; Cai, Hengxing; Meng, Qinggong; Li, Bo

    2015-04-01

    To evaluate the effectiveness of the screw-based intermaxillary traction combined with occlusal splint in the treatment of pediatric mandibular condylar fracture. Between June 2005 and December 2013, 35 pediatric patients with 49 mandibular condylar fractures were treated, and the clinical data were retrospectively reviewed. There were 25 boys and 10 girls, aged 3-13 years (mean, 7.3 years). The injury causes included falling (18 cases), traffic accident (14 cases), and violence (3 cases). The time between injury and treatment was 2-30 days (mean, 6.8 days). Restricted mouth opening was observed, and the maximal mouth opening was (22.74 +/- 7.22) mm except 3 patients who were too young to measure. Condylar fractures were located at the left (12 cases), at the right (9 cases), at bilateral (14 cases) based on the sites; and fractures were classified as intracapsular (35 fractures), neck (10 fractures), and subcondylar (4 fractures) based on the fracture line. Four self-drilling titanium screws were inserted into the alveolar bone of both maxilla and mandible. After screw inserting, an occlusal splint with a fulcrum was used on the affected side and elastic band was put to perform anterior intermaxillary traction. After 1 month, the screws and splint were removed. Follow-up examinations were carried out on schedule. All the patients were followed up from 6 months to 8 years and 10 months (median, 71 months). No screw-related complication occurred in the others except one case of screw loosening. The postoperative maximal mouth opening was (38.82 +/- 2.02) nim. Mild joint noise was found in 4 cases and opening deviation occurred in 6 cases. Radiographic results demonstrated complete condyle remodeling was achieved in 24 cases (32 fractures), and moderate remodeling in 11 cases (17 fractures) at last follow-up. The screw-based intermaxillary traction combined with occlusal splint might be an effective method for pediatric mandibular condylar fracture. The screw

  15. A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws.

    Science.gov (United States)

    Eu-Jin Cheah, Andre; Behn, Anthony W; Comer, Garet; Yao, Jeffrey

    2017-12-01

    Surgeons confronted with a long spiral metacarpal fracture may choose to fix it solely with lagged screws. A biomechanical analysis of a metacarpal spiral fracture model was performed to determine whether 3 1.5-mm screws or 2 2.0-mm screws provided more stability during bending and torsional loading. Second and third metacarpals were harvested from 12 matched pairs of fresh-frozen cadaveric hands and spiral fractures were created. One specimen from each matched pair was fixed with 2 2.0-mm lagged screws whereas the other was fixed with 3 1.5-mm lagged screws. Nine pairs underwent combined cyclic cantilever bending and axial compressive loading followed by loading to failure. Nine additional pairs were subjected to cyclic external rotation while under a constant axial compressive load and were subsequently externally rotated to failure under a constant axial compressive load. Paired t tests were used to compare cyclic creep, stiffness, displacement, rotation, and peak load levels. Average failure torque for all specimens was 7.2 ± 1.7 Nm. In cyclic torsional testing, the group with 2 screws exhibited significantly less rotational creep than the one with 3 screws. A single specimen in the group with 2 screws failed before cyclic bending tests were completed. No other significant differences were found between test groups during torsional or bending tests. Both constructs were biomechanically similar except that the construct with 2 screws displayed significantly less loosening during torsional cyclic loading, although the difference was small and may not be clinically meaningful. Because we found no obvious biomechanical advantage to using 3 1.5-mm lagged screws to fix long spiral metacarpal fractures, the time efficiency and decreased implant costs of using 2-2.0 mm lagged screws may be preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. Screw elastic intramedullary nail for the management of adult forearm fractures

    Directory of Open Access Journals (Sweden)

    Wasudeo Gadegone

    2012-01-01

    Full Text Available Background: The failure of the conventional nailing of both forearm bones or isolated fractures of radius and ulna pose a potential problem of nail migration and rotational instability, despite the best reduction. The purpose of this paper is to evaluate the results of screw elastic intramedullary nail for the treatment of adult diaphyseal fractures of both forearm bones, which effectively addresses the problems associated with the conventional nailing systems for the forearm fractures. Materials and Methods: Seventy-six adults with forearm fractures (radius and ulna or isolated fracture of the single bone were retrospectively evaluated. Fifty males and 26 females with the mean age of 38 years (range, 18-70 years underwent closed reduction and screw intramedullary nail fixation. Ten patients required limited open reduction. The fractures were classified according to the AO/OTA system. The average followup was 12 months (range, 6 to 18 months. Results: The mean surgical time was 45 minutes (35 to 65 minutes. The meantime to union was 14 weeks (10-21 weeks. The results were graded as excellent in 50, good in 18 patients, and acceptable in eight patients, using the criteria of Grace and Eversman. We had superficial infection in three cases, one case of delayed infection, painful bursa in two cases, delayed union in two cases, malunion with dislocation of the DRUJ in two cases, injury to the extensor tendon of the thumb in one case, and one case of incomplete radioulnar synostosis. Conclusion: Closed reduction and internal fixation of forearm fractures by screw intramedullary nails reestablishes the near normal relationship of the fractured fragments. Screw intramedullary nail effectively controls both rotatory forces and the migration of the nail. It produces excellent clinical results in isolated fractures of either bones, as well as both bones of the forearm in adults.

  17. Biomechanical analysis of titanium fixation plates and screws in ...

    African Journals Online (AJOL)

    Conclusions: It was concluded that the use of double 4-hole straight plates provided the sufficient stability on the osteotomy site when compared with the other rigid fixation methods used in this study. Key words: Bone plates, bone screws, finite element analysis, jaw fixation techniques, mandible, mandibular osteotomy ...

  18. [Intramedullary nailing combined with cannulated screw in treating femoral condyles fractures].

    Science.gov (United States)

    Shen, Guo-Qing; Zhang, Hao; Long, Da-Fu; Li, Zheng-Wen; Tan, Ying-Dong

    2017-07-25

    To observe the clinical effects of retrograde intramedullary nailing and cannulated screws in the treatment of femoral condylar fracture. From June 2009 to June 2015, 13 patients with femoral condyles fracture were treated by retrograde intramedullary nailing and cannulated screws including 6 males and 7 females with an average age of 46.1 years old ranging from 16 to 76 years old. There were 10 cases of closed fractures, 3 cases of open fraetures. According to AO classification criteriam, 4 cases were type C1, 7 cases were type C2, 2 cases were type C3. Postoperative reduction of fracture and the knee joint function recovery were observed. All patients were followed up for 12 to 36 months with a mean of 24 months. X-ray examination showed that the union time of fracture was 18 to 24 weeks, 21 weeks on average. There were no cases of loosening, breakage of internal fixators and re-fracture. Hospital for Special Surgery(HSS) knee score was 90.07±4.99 at 1 year after the operation. The clinical efficacy for retrograde intramedullary nailing and cannulated screw for the treatment of femoral condyles fracture was excellent. It can improve the anatomical reattachment rate and reduce the complications and promote the knee functional recovery.

  19. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.

    Science.gov (United States)

    Knobe, Matthias; Nagel, Philipp; Maier, Klaus-Jürgen; Gradl, Gertraud; Buecking, Benjamin; Sönmez, Tolga T; Modabber, Ali; Prescher, Andreas; Pape, Hans-Christoph

    2016-01-01

    Third-generation cephalomedullary nails currently represent the gold standard in the treatment of unstable trochanteric femur fractures. Recently, an extramedullary rotationally stable screw-anchor system (RoSA) has been developed. It was designed to combine the benefits of screw and blade and to improve stability using a locked trochanteric stabilizing plate (TSP). The purpose of this study was to compare the biomechanical behavior of RoSA/TSP and the proximal femoral nail antirotation (PFNA). Standardized AO/OTA 31A2.2 fractures were induced by an oscillating saw in 10 paired human specimens (n = 20; mean age = 85 years; range: 71-96 years). The fractures were stabilized by either the RoSA/TSP (Koenigsee Implants, Allendorf, Germany) or the PFNA (DePuy Synthes, Zuchwil, Switzerland). Femurs were positioned in 25 degrees of adduction and 10 degrees of posterior flexion and were cyclically loaded with axial sinusoidal pattern at 0.5 Hz, starting at 300 N, with stepwise increase by 300 N every 500 cycles until bone-implant failure occurred. After every load step, the samples were measured visually and radiographically. Femoral head migration was assessed. The stiffness at the load up to the clinically relevant load step of 1800 N (639 ± 378 N/mm (RoSA/TSP) vs. 673 ± 227 N/mm (PFNA); P = 0.542) was comparable, as was the failure load (3000 ± 787 N vs. 3780 ± 874 N; P = 0.059). Up to 1800 N, no femoral head rotation, head migration, or femoral neck shortening were observed either for RoSA/TSP or PFNA. Whereas failure of the PFNA subsumed fractures of the greater trochanter and the lateral wall, a posterior femoral neck fracture with a significantly increased femoral neck shortening (1.7 mm vs. 0 mm; P = 0.012) was the cause of failure with RoSA/TSP. This specific kind of failure was induced by a femoral neck weakening caused by the posterior TSP stabilizing screw. There was no significant difference in biomechanical properties between the RoSA/TSP and the PFNA for

  20. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    Science.gov (United States)

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  1. Comparison of surgical techniques of 111 medial malleolar fractures classified by fracture geometry.

    Science.gov (United States)

    Ebraheim, Nabil A; Ludwig, Todd; Weston, John T; Carroll, Trevor; Liu, Jiayong

    2014-05-01

    Evaluation of operative techniques used for medial malleolar fractures by classifying fracture geometry has not been well documented. One hundred eleven patients with medial malleolar fractures (transverse n = 63, oblique n = 29, vertical n = 7, comminuted n = 12) were included in this study. Seventy-two patients had complicating comorbidities. All patients were treated with buttress plate, lag screw, tension band, or K-wire fixation. Treatment outcomes were evaluated on the basis of radiological outcome (union, malunion, delayed union, or nonunion), need for operative revision, presence of postoperative complications, and AOFAS Ankle-Hindfoot score. For transverse fractures, tension band fixation showed the highest rate of union (79%), highest average AOFAS score (86), lowest revision rate (5%), and lowest complication rate (16%). For oblique fractures, lag screws showed the highest rate of union (71%), highest average AOFAS score (80), lowest revision rate (19%), and lowest complication rate (33%) of the commonly used fixation techniques. For vertical fractures, buttress plating was used in every case but 1, achieving union (whether normal or delayed) in all cases with an average AOFAS score of 84, no revisions, and a 17% complication rate. Comminuted fractures had relatively poor outcomes regardless of fixation method. The results of this study suggest that both tension bands and lag screws result in similar rates of union for transverse fractures of the medial malleolus, but that tension band constructs are associated with less need for revision surgery and fewer complications. In addition, our data demonstrate that oblique fractures were most effectively treated with lag screws and that vertical fractures attained superior outcomes with buttress plating. Level III, retrospective comparative series.

  2. Effect of Cortical Screw Diameter on Reduction and Stabilization of Type III Distal Phalanx Fractures: An Equine Cadaveric Study.

    Science.gov (United States)

    Kay, Alastair T; Durgam, Sushmitha; Stewart, Matthew; Joslyn, Stephen; Schaeffer, David J; Horn, Gavin; Kesler, Richard; Chew, Peter

    2016-11-01

    To compare reduction of type III distal phalangeal fractures using 4.5 and 5.5 mm cortical screws placed in lag fashion and an intact hoof capsule model. Cadaveric experimental study. Hooves from 12 adult horses (n=24). Sagittal fractures were created in pairs of distal phalanges after distal interphalangeal joint disarticulation and were reduced with either 4.5 or 5.5 mm cortical screws placed in lag fashion. Contralateral phalanges served as non-reduced controls. Fracture reduction following screw placement was assessed by comparing pre-reduction and post-reduction fracture gap measurements from radiographs using paired t-tests. Effects of incremental loading (0, 135, 270, 540, 800, 1070, and 1335 kg) on fracture gaps in 6 phalanges reduced with 4.5 mm screws and 5 phalanges reduced with 5.5 mm screws were measured from fluoroscopic images and assessed by 2-way ANOVA. Significance was set at Pfractures were reliably created. Only 5.5 mm cortical screws, not 4.5 mm screws, significantly reduced fracture gaps and constrained fracture gap expansion 3 cm distal to the articular surface. Compressive loading closed the fracture gaps at the articular surface in both non-reduced control groups and those reduced with either 5.5 or 4.5 mm screws. The 5.5 mm cortical screws were more effective than 4.5 mm screws in reducing type III distal phalanx fractures and restricting distal fracture gap expansion under load. © Copyright 2016 by The American College of Veterinary Surgeons.

  3. Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.

    Science.gov (United States)

    Burkhart, Klaus Josef; Mueller, Lars P; Krezdorn, David; Appelmann, Philipp; Prommersberger, Karl J; Sternstein, Werner; Rommens, Pol M

    2007-12-01

    Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.

  4. Numerical analysis of standard and modified osteosynthesis in long bone fractures treatment.

    Science.gov (United States)

    Sisljagić, Vladimir; Jovanović, Savo; Mrcela, Tomislav; Radić, Radivoje; Selthofer, Robert; Mrcela, Milanka

    2010-03-01

    The fundamental problem in osteoporotic fracture treatment is significant decrease in bone mass and bone tissue density resulting in decreased firmness and elasticity of osteoporotic bone. Application of standard implants and standard surgical techniques in osteoporotic bone fracture treatment makes it almost impossible to achieve stable osteosynthesis sufficient for early mobility, verticalization and load. Taking into account the form and the size of the contact surface as well as distribution of forces between the osteosynthetic materials and the bone tissue numerical analysis showed advantages of modified osteosynthesis with bone cement filling in the screw bed. The applied numerical model consisted of three sub-models: 3D model from solid elements, 3D cross section of the contact between the plate and the bone and the part of 3D cross section of the screw head and body. We have reached the conclusion that modified osteosynthesis with bone cement resulted in weaker strain in the part of the plate above the fracture fissure, more even strain on the screws, plate and bone, more even strain distribution along all the screws' bodies, significantly greater strain in the part of the screw head opposite to the fracture fissure, firm connection of the screw head and neck and the plate hole with the whole plate and more even bone strain around the screw.

  5. Scapula fracture incidence in reverse total shoulder arthroplasty using screws above or below metaglene central cage: clinical and biomechanical outcomes.

    Science.gov (United States)

    Kennon, Justin C; Lu, Caroline; McGee-Lawrence, Meghan E; Crosby, Lynn A

    2017-06-01

    Reverse total shoulder arthroplasty (RTSA) is a viable treatment option for rotator cuff tear arthropathy but carries a complication risk of scapular fracture. We hypothesized that using screws above the central glenoid axis for metaglene fixation creates a stress riser contributing to increased scapula fracture incidence. Clinical type III scapular fracture incidence was determined with screw placement correlation: superior screw vs. screws placed exclusively below the glenoid midpoint. Cadaveric RTSA biomechanical modeling was employed to analyze scapular fractures. We reviewed 318 single-surgeon single-implant RTSAs with screw correlation to identify type III scapular fractures. Seventeen cadaveric scapula specimens were matched for bone mineral density, metaglenes implanted, and fixation with 2 screw configurations: inferior screws alone (group 1 INF ) vs. inferior screws with one additional superior screw (group 2 SUP ). Biomechanical load to failure was analyzed. Of 206 patients, 9 (4.4%) from the superior screw group experienced scapula fractures (type III); 0 fractures (0/112; 0%) were identified in the inferior screw group. Biomechanically, superior screw constructs (group 2 SUP ) demonstrated significantly (P < .05) lower load to failure (1077 N vs. 1970 N) compared with constructs with no superior screws (group 1 INF ). There was no significant age or bone mineral density discrepancy. Clinical scapular fracture incidence significantly decreased (P < .05) for patients with no screws placed above the central cage compared with patients with superior metaglene screws. Biomechanical modeling demonstrates significant construct compromise when screws are used above the central cage, fracturing at nearly half the ultimate load of the inferior screw constructs. We recommend use of inferior screws, all positioned below the central glenoid axis, unless necessary to stabilize the metaglene construct. Copyright © 2016 Journal of Shoulder and Elbow Surgery

  6. Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study.

    Science.gov (United States)

    Chen, Pengbo; Lu, Hua; Shen, Hao; Wang, Wei; Ni, Binbin; Chen, Jishizhan

    2017-02-23

    Lateral column tibial plateau fracture fixation with a locking screw plate has higher mechanical stability than other fixation methods. The objectives of the present study were to introduce two newly designed locking anatomic plates for lateral tibial plateau fracture and to demonstrate their characteristics of the fixation complexes under the axial loads. Three different 3D finite element models of the lateral tibial plateau fracture with the bone plates were created. Various axial forces (100, 500, 1000, and 1500 N) were applied to simulate the axial compressive load on an adult knee during daily life. The equivalent maps of displacement and stress were output, and relative displacement was calculated along the fracture lines. The displacement and stresses in the fixation complexes increased with the axial force. The equivalent displacement or stress map of each fixation under different axial forces showed similar distributing characteristics. The motion characteristics of the three models differed, and the max-shear stress of trabecula increased with the axial load. These two novel plates could fix lateral tibial plateau fractures involving anterolateral and posterolateral fragments. Motions after open reduction and stable internal fixation should be advised to decrease the risk of trabecular microfracture. The relative displacement of the posterolateral fragments is different when using anterolateral plate and posterolateral plate, which should be considered in choosing the implants for different posterolateral plateau fractures.

  7. Treatment options for unstable trochanteric fractures: Screw or helical proxima femoral nail.

    Science.gov (United States)

    Bajpai, Jeetendra; Maheshwari, Rajesh; Bajpai, Akansha; Saini, Sumit

    2015-01-01

    To compare treatment outcome of screw proximal femoral nail (PFN) system with that of a helical PFN. The study included 77 patients with closed unstable intertrochanteric fracture classified as AO 31A2&31A3, between June 2008 to August 2011. Inclusion criteria were: all mature skeletons above 50 years of age; closed unstable trochanteric fracture classified as AO 31A2&A3. Exclusion criteria were: immature skeleton, pathological fracture of any cause other than osteoporosis, inability to walk inde- pendently prior to injury. Patients were randomized to 2 treatment groups based on admission sequence. Forty patients were treated with screw PFN and thirty seven were treated with helical PFN. Both groups were similar in respect of time of surgery, blood loss and functional assessment and duration of hospitalization. In screw PFN group 2 patients had superficial wound infection, 1 patient had persistent hip pain and 1 patient had shortening>1 cm buttrochanteric fractures even in Indian patients where the bones are narrow and neck diameter is small. It is an implant of choice for osteoporotic and unstable trochanteric fractures.

  8. Implant Material, Type of Fixation at the Shaft, and Position of Plate Modify Biomechanics of Distal Femur Plate Osteosynthesis.

    Science.gov (United States)

    Kandemir, Utku; Augat, Peter; Konowalczyk, Stefanie; Wipf, Felix; von Oldenburg, Geert; Schmidt, Ulf

    2017-08-01

    To investigate whether (1) the type of fixation at the shaft (hybrid vs. locking), (2) the position of the plate (offset vs. contact) and (3) the implant material has a significant effect on (a) construct stiffness and (b) fatigue life in a distal femur extraarticular comminuted fracture model using the same design of distal femur periarticular locking plate. An extraarticular severely comminuted distal femoral fracture pattern (OTA/AO 33-A3) was simulated using artificial bone substitutes. Ten-hole distal lateral femur locking plates were used for fixation per the recommended surgical technique. At the distal metaphyseal fragment, all possible locking screws were placed. For the proximal diaphyseal fragment, different types of screws were used to create 4 different fixation constructs: (1) stainless steel hybrid (SSH), (2) stainless steel locked (SSL), (3) titanium locked (TiL), and (4) stainless steel locked with 5-mm offset at the diaphysis (SSLO). Six specimens of each construct configuration were tested. First, each specimen was nondestructively loaded axially to determine the stiffness. Then, each specimen was cyclically loaded with increasing load levels until failure. Construct Stiffness: The fixation construct with a stainless steel plate and hybrid fixation (SSH) had the highest stiffness followed by the construct with a stainless steel plate and locking screws (SSL) and were not statistically different from each other. Offset placement (SSLO) and using a titanium implant (TiL) significantly reduced construct stiffness. Fatigue Failure: The stainless steel with hybrid fixation group (SSH) withstood the most number of cycles to failure and higher loads, followed by the stainless steel plate and locking screw group (SSL), stainless steel plate with locking screws and offset group (SSLO), and the titanium plate and locking screws group (TiL) consecutively. Offset placement (SSLO) as well as using a titanium implant (TiL) reduced cycles to failure. Using the

  9. Percutaneous locking plates for fractures of the distal tibia: our experience and a review of the literature.

    Science.gov (United States)

    Ahmad, Mudussar Abrar; Sivaraman, Alagappan; Zia, Ahmed; Rai, Amarjit; Patel, Amratlal D

    2012-02-01

    Distal tibial metaphyseal fractures pose many complexities. This study assessed the outcomes of distal tibial fractures treated with medial locking plates. Eighteen patients were selected based on the fracture pattern and classified using the AO classification and stabilized with an AO medial tibial locking plate. Time to fracture union, complications, and outcomes were assessed with the American Orthopedic Foot and Ankle Society Ankle score at 12 months. Sixteen of the 18 patients achieved fracture union, with 1 patient lost to follow-up. Twelve fractures united within 24 weeks, with an average union time of 23.1 weeks. Three delayed unions, two at 28 weeks and one at 56 weeks. The average time to union was 32 weeks in the smokers and 15.3 weeks in the nonsmokers. Five of the 18 patients (27%) developed complications. One superficial wound infection, and one chronic wound infection, resulting in nonunion at 56 weeks, requiring revision. Two patients required plate removal, one after sustaining an open fracture at the proximal end of the plate 6 months after surgery (postfracture union)and the other for painful hardware. One patient had implant failure of three proximal diaphyseal locking screws at the screwhead/neck junction, but successful fracture union. The average American Orthopedic Foot and Ankle Society ankle score was 88.8 overall, and 92.1 in fractures that united within 24 weeks. Distal tibial locking plates have high fracture union rates, minimum soft tissue complications, and good functional outcomes. The literature shows similar fracture union and complication rates in locking and nonlocking plates. Copyright © 2012 by Lippincott Williams & Wilkins

  10. "A" shape plate for open rigid internal fixation of mandible condyle neck fracture.

    Science.gov (United States)

    Kozakiewicz, Marcin; Swiniarski, Jacek

    2014-09-01

    Reduction of the fracture is crucial for proper outcome of the treatment. The stability of reduction is closed connected to the method of its fixation. The topic of condylar fracture osteosynthesis still remains highly controversial and challenging. That is why authors decided to propose novel design of the fixating plate and the example of its application. The aim of this study was to present A-shape plate dedicated to rigid fixation of mandible condyle neck fracture. A-shape condylar plate (ACP) design is prepared of 1.0 mm thick titanium alloy (grade 5) sheet: posterior and anterior bars are reinforced by widening to 2.5 mm and anatomically curved along the compression and traction lines in ramus and condylar neck. Superior three-hole-group has triangular organization and located on the level of condylar head. The inferior extensions of the bars are equipped in three holes located at each of lower tails. Connecting bar (2.0 mm wide) connects the first hole of each lower tails closing upper part of ACP in triangular shape. The connecting bar runs along compression line of condylar neck. Holes in ACP has 2.0 mm diameter for locking or normal screws. Height of ACP is 31 mm. The proposed new type of plate was compared by finite element analysis (FEA) to nowadays manufactured 9-hole trapezoid plate as the most similar device. ACP design was evaluated by finite element analysis (FEA) and later applied in patient affected with high condylar neck fracture complicated by fracture of coronoid process. FEA revealed high strength of ACP and more stabile fixation than trapezoid plate. The result was caused by multipoint fixation at three regions of the plate and reinforced bars supported by semi-horizontal connecting bar. Clinical application of ACP was as versatile as makes possible to simultaneous fixation of high condylar neck and coronoid process fracture. Application of proposed A-shape condylar plate would be possible in all levels of neck fractures and can be use

  11. Full title: Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures.

    Science.gov (United States)

    Mugnai, Raffaele; Tarallo, Luigi; Capra, Francesco; Catani, Fabio

    2018-05-25

    As the popularity of volar locked plate fixation for distal radius fractures has increased, so have the number and variety of implants, including variations in plate design, the size and angle of the screws, the locking screw mechanism, and the material of the plates. carbon-fiber reinforced polyetheretherketone (CFR-PEEK) plate features similar biomechanical properties to metallic plates, representing, therefore, an optimal alternative for the treatment of distal radius fractures. three different materials-composed plates were evaluated: stainless steel volar lateral column (Zimmer); titanium DVR (Hand Innovations); CFR-PEEK DiPHOS-RM (Lima Corporate). Six plates for each type were implanted in sawbones and an extra-articular rectangular osteotomy was created. Three plates for each material were tested for load to failure and bending stiffness in axial compression. Moreover, 3 constructs for each plate were evaluated after dynamically loading for 6000 cycles of fatigue. the mean bending stiffness pre-fatigue was significantly higher for the stainless steel plate. The titanium plate yielded the higher load to failure both pre and post fatigue. After cyclic loading, the bending stiffness increased by a mean of 24% for the stainless steel plate; 33% for the titanium; and 17% for the CFR-PEEK plate. The mean load to failure post-fatigue increased by a mean of 10% for the stainless steel and 14% for CFR-PEEK plates, whereas it decreased (-16%) for the titanium plate. Statistical analysis between groups reported significant values (p plastic deformation, and lower load to failure. N/A. Copyright © 2018. Published by Elsevier Masson SAS.

  12. Biomechanical analysis of titanium fixation plates and screws in ...

    African Journals Online (AJOL)

    hole Y plates with monocortical screws. 150 N incisal occlusal loads were simulated on the models. The commercial ANSYS software was utilized to calculate the Von Mises stresses on fixative appliances. Results: The highest Von Mises stress ...

  13. Treating Simple Tibia Fractures with Poly-DL-Lactic Acid Screw as a ...

    African Journals Online (AJOL)

    ) absorbable screw as a ... fractures. Keywords: Simple tibia fracture, Fracture healing time Poly-DL-lactic acid, Poly-DL-Lactic Acid, ..... bilateral cortex of the bone due to the weak anti- ... Hu YL, Yuan WQ, Wang LF, Liu HF, Jin D. A prospective.

  14. Biomechanical stability of a supra-acetabular pedicle screw internal fixation device (INFIX) vs external fixation and plates for vertically unstable pelvic fractures.

    Science.gov (United States)

    Vigdorchik, Jonathan M; Esquivel, Amanda O; Jin, Xin; Yang, King H; Onwudiwe, Ndidi A; Vaidya, Rahul

    2012-09-27

    We have recently developed a subcutaneous anterior pelvic fixation technique (INFIX). This internal fixator permits patients to sit, roll over in bed and lie on their sides without the cumbersome external appliances or their complications. The purpose of this study was to evaluate the biomechanical stability of this novel supraacetabular pedicle screw internal fixation construct (INFIX) and compare it to standard internal fixation and external fixation techniques in a single stance pelvic fracture model. Nine synthetic pelves with a simulated anterior posterior compression type III injury were placed into three groups (External Fixator, INFIX and Internal Fixation). Displacement, total axial stiffness, and the stiffness at the pubic symphysis and SI joint were calculated. Displacement and stiffness were compared by ANOVA with a Bonferroni adjustment for multiple comparisons The mean displacement at the pubic symphysis was 20, 9 and 0.8 mm for external fixation, INFIX and internal fixation, respectively. Plate fixation was significantly stiffer than the INFIX and external Fixator (P = 0.01) at the symphysis pubis. The INFIX device was significantly stiffer than external fixation (P = 0.017) at the symphysis pubis. There was no significant difference in SI joint displacement between any of the groups. Anterior plate fixation is stiffer than both the INFIX and external fixation in single stance pelvic fracture model. The INFIX was stiffer than external fixation for both overall axial stiffness, and stiffness at the pubic symphysis. Combined with the presumed benefit of minimizing the complications associated with external fixation, the INFIX may be a more preferable option for temporary anterior pelvic fixation in situations where external fixation may have otherwise been used.

  15. Magnesium-Based Absorbable Metal Screws for Intra-Articular Fracture Fixation

    Directory of Open Access Journals (Sweden)

    Roland Biber

    2016-01-01

    Full Text Available MAGNEZIX® (Syntellix AG, Hanover, Germany is a biodegradable magnesium-based alloy (MgYREZr which is currently used to manufacture bioabsorbable compression screws. To date, there are very few studies reporting on a limited number of elective foot surgeries using this innovative implant. This case report describes the application of this screw for osteochondral fracture fixation at the humeral capitulum next to a loose radial head prosthesis, which was revised at the same time. The clinical course was uneventful. Degradation of the magnesium alloy did not interfere with fracture healing. Showing an excellent clinical result and free range-of-motion, the contour of the implant was still visible in a one-year follow-up.

  16. Cerclage wire and lag screw fixation of the lateral malleolus in supination and external rotation fractures of the ankle.

    Science.gov (United States)

    Bajwa, Amarjit S; Gantz, D E

    2005-01-01

    Wound dehiscence and exposed lateral hardware can occur after open reduction internal fixation of lateral malleolus. The bulk of a lateral plate and the minimum soft tissue over the lateral malleolus may contribute to this situation. The objective of this study was to evaluate a series of patients with lateral malleolar fractures treated with operative reduction using minimal hardware. We wanted to observe whether there was any loss of reduction and whether there were any incidences of soft tissue disruption. Fifty-two patients with long spiral fracture of the lateral malleolus in a supination-external rotation injury were treated with two or three 3.5-mm lag screws inserted 1 cm apart and 1 or 2 circlage wires. Less rigid fixation was supplemented with a below-the-knee plaster cast. All patients were followed up until clinical and radiological evidence of fracture healing at 6, 10, and 14 weeks postoperatively. By 10 weeks, all patients were full weight bearing, although most patients still limped. At 14 weeks' follow-up, there were no infections or wound dehiscences. All patients were able to return to their activities of daily living. All the fractures had united without loss of original position. Two fractures of the posterior bone spikes seen during surgery united uneventfully. Long spiral fractures of the lateral malleolus of the ankle can be treated successfully with 2 or 3 lag screws and circlage wires without compromising the outcome of the fracture healing.

  17. High failure rate of trochanteric fracture osteosynthesis with proximal femoral locking compression plate.

    Science.gov (United States)

    Wirtz, C; Abbassi, F; Evangelopoulos, D S; Kohl, S; Siebenrock, K A; Krüger, A

    2013-06-01

    Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. Early results for PF-LCP osteosynthesis show major

  18. Computed tomography fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures

    International Nuclear Information System (INIS)

    Iguchi, Toshihiro; Ogawa, Ken-Ichi; Doi, Takeshi; Munetomo, Kazuo; Miyasho, Koji; Hiraki, Takao; Kanazawa, Susumu; Ozaki, Toshifumi

    2010-01-01

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of the computed tomography (CT) fluoroscopy-guided placement of iliosacral screws in patients with unstable posterior pelvic fractures. Six patients (four women and two men; mean age 55.8 years; range 35-77 years) with unstable posterior pelvic fractures underwent iliosacral screw placement under CT fluoroscopy guidance between November 2007 and August 2008. Unstable pelvic ring injury (AO types B and C) was the indication for this procedure. In all the six patients except one, CT fluoroscopy-guided placement had been technically successful. In one patient, a second screw had been inserted, with a tilt to the caudal site, and slightly advanced into the extrasacral body; afterward, it could be exchanged safely for a shorter screw. Five patients and one patient underwent placement of two screws and one screw, respectively. The mean duration of the procedure was 15.0 min (range 9-30 min) per screw; the duration was 12.3 min and 18.2 min for the first and second screws, respectively. No complications requiring treatment occurred during or after the procedure. The mean clinical and radiologic follow-up period was 14 months (range 6-21 months). All pelvic injuries had healed satisfactorily, without complication, and all patients are now doing well clinically and can walk. CT fluoroscopy-guided placement of iliosacral screws is a safe and effective treatment in patients with unstable posterior pelvic fractures. (orig.)

  19. Intertrochanteric fractures in elderly high risk patients treated with Ender nails and compression screw

    Directory of Open Access Journals (Sweden)

    Gangadharan Sidhartha

    2010-01-01

    Full Text Available Background: Ender and Simon Weidner popularized the concept of closed condylocephlic nailing for intertrochanteric fractures in 1970. The clinical experience of authors revealed that Ender nailing alone cannot provide secure fixation in elderly patients with osteoporosis. Hence we conducted a study to evaluate the efficacy of a combined fixation procedure using Ender nails and a cannulated compression screw for intertrochanteric fractures. Materials and Methods: 76 patients with intertrochanteric fractures were treated using intramedullary Ender nails and cannulated compression screw from January 2004 to December 2007. The mean age of the patients was 80 years (range 70-105 years.Using the Evan′s system of classification 49 were stable and 27 unstable fractures. Inclusion criteria was high risk elderly patients (age > 70 years with intertrochanteric fracture. The exclusion criteria included patients with pressure sores over the trochanteric region. Many patients had pre-existing co-morbidities like diabetes mellitus, hypertension, COPD, ischemic heart disease, CVA and coronary artery bypass surgery. The two Ender nails of 4.5mm each were passed across the fracture site into the proximal neck. This was reinforced with a 6.5 mm cannulated compression screw passed from the sub trochanteric region, across the fracture into the head. Results: The mean follow-up was 14 months (range 9-19 months Average time to fracture union was 10 weeks (range 6-16 weeks. The mean knee ROM was 130o (± 5o. There was no case of nail penetration into hip joint. In five cases with advanced osteoporosis there was minimal migration of Ender nails distally. Conclusions: The Ender nailing combined with compression screw fixation in cases of intertrochanteric fractures in high risk elderly patients could achieve reliable fracture stability with minimal complications.

  20. Minimally invasive surgical treatment for unstable fractures of the proximal phalanx: intramedullary screw

    Directory of Open Access Journals (Sweden)

    Marcio Aurélio Aita

    2016-02-01

    Full Text Available ABSTRACT OBJECTIVE: To analyze the clinical-functional parameters and quality of life of patients undergoing minimally invasive surgical treatment for extra-articular fractures of the proximal phalanx, using an intramedullary screw (Acutrak(r. METHODS: Between January 2011 and September 2014, a prospective study was conducted on 41 patients (48 fingers with unstable extra-articular fractures of the proximal phalanx, who underwent minimally invasive surgical treatment using an intramedullary screw (Acutrak(r. These patients were evaluated 12 months after the surgery by means of the DASH quality-of-life questionnaire, VAS pain scale, measurement of range of motion (ROM, in degrees and radiographic assessment. RESULTS: All the patients achieved adequate reduction and consolidation of their fractures. There were statistically significant improvements in quality of life on the DASH scale, pain on the VAS scale and range of motion. CONCLUSION: The minimally invasive technique for treating unstable extra-articular fractures of the proximal phalanx using an intramedullary screw (Acutrak(r is effective and safe, and it presents satisfactory clinical-functional results.

  1. C-2 anterior plate-screw fixation: a quantitative anatomical and morphometric evaluation.

    Science.gov (United States)

    Senoglu, M; Ozbag, D; Gumusalan, Y

    2010-01-01

    Discectomy and inter-vertebral body fusion combined with the anterior plate-screw fixa tion is the common procedure in cervical spine surgery. But the anterior plate-screw fixation of the C2 spine has been the uncommon surgical procedure. In this study, we analyze the anatomy of the C2 body relevant to C2 anterior plate-screw fixation. Eighty-six dried C2 spines were evaluated directly for this study. Measurements were made on the C2 body width and midsagittal anteroposterior (AP) depth and the anteroposterior parasagittal depth 5 mm lateral to midline on the inferior endplates, in addition to on the middle body. Measurements also were made of anteroposterior parasagittal vertebral depth with both medial and lateral inclination of 10 degrees, with respect to the parasagittal plane of the vertebral body. The ideal maximum screw length and trajectory was found to be AP medial parasagittal depth of inferior surface of the C2 body [Right: 13.7 +/- 1.4 mm (11.0-17.9), Left: 13.6 +/- 1.5 mm (10.7-17.8)]. We report the measurements of the vertebral body of the C2. We think these measurements provide guidelines for operating on the anterior C2 spine, and enhance the confidence interval for the surgeon (Tab. 3, Fig. 1, Ref. 24).

  2. Chitosan-coated Stainless Steel Screws for Fixation in Contaminated Fractures

    OpenAIRE

    Greene, Alex H.; Bumgardner, Joel D.; Yang, Yunzhi; Moseley, Jon; Haggard, Warren O.

    2008-01-01

    Stainless steel screws and other internal fixation devices are used routinely to stabilize bacteria-contaminated bone fractures from multiple injury mechanisms. In this preliminary study, we hypothesize that a chitosan coating either unloaded or loaded with an antibiotic, gentamicin, could lessen or prevent these devices from becoming an initial nidus for infection. The questions investigated for this hypothesis were: (1) how much of the sterilized coating remains on the screw with simulated ...

  3. Percutaneous Cement-Augmented Screws Fixation in the Fractures of the Aging Spine: Is It the Solution?

    Directory of Open Access Journals (Sweden)

    Sébastien Pesenti

    2014-01-01

    Full Text Available Introduction. Management of elderly patients with thoracolumbar fractures is still challenging due to frequent osteoporosis and risk of screws pull-out. The aim of this study was to evaluate results of a percutaneous-only procedure to treat these fragile patients using cement-augmented screws. Methods. 12 patients diagnosed with a thoracolumbar fracture associated with an important loss of bone stock were included in this prospective study. Surgical procedure included systematically a percutaneous osteosynthesis using cemented fenestrated screws. When necessary, additional anterior support was performed using a kyphoplasty procedure. Clinical and radiographic evaluations were performed using CT scan. Results. On the whole series, 15 fractures were diagnosed and 96 cemented screws were inserted. The difference between the pre- and postoperative vertebral kyphosis was statistically significant (12.9° versus 4.4°, P=0.0006. No extrapedicular screw was reported and one patient was diagnosed with a cement-related pulmonary embolism. During follow-up period, no infectious complications, implant failures, or pull-out screws were noticed. Discussion. Aging spine is becoming an increasing public health issue. Management of these patients requires specific attention due to the augmented risk of complications. Using percutaneous-only screws fixation with cemented screw provides satisfactory results. A rigorous technique is mandatory in order to achieve best outcomes.

  4. Treating Simple Tibia Fractures with Poly-DL-Lactic Acid Screw as a ...

    African Journals Online (AJOL)

    Purpose: To investigate the curative effect of poly-DL-lactic acid (PDLLA) absorbable screw as a locked intramedullary nail for simple tibia fractures. Methods: In this study, 35 patients treated with the PDLLA screw were observed, and another 35 patients treated with a traditional locking intramedullary nail were treated as ...

  5. Lag screw stabilization of a cervical vertebral fracture by use of computed tomography in a horse

    International Nuclear Information System (INIS)

    Barnes, H.G.; Tucker, R.L.; Grant, B.D.; Roberts, G.D.; Prades, M.

    1995-01-01

    A traumatic fracture of C2 was diagnosed radiographically in a 1-year-old German Warm-blood stallion. Fracture configuration was difficult to see on survey radiographs. Computed tomography yielded a more accurate assessment of the fracture and facilitated fracture repair with cortical lag screws. Precise screw placement, to avoid spinal cord damage, was obtained by use of computed tomography. Follow-up radiography revealed normal bone healing, and the horse was in dressage schooling 24 months after surgery

  6. Dual-energy X-ray absorptiometry and force-plate analysis of gait in dogs with healed femora after leg-lengthening plate fixation

    International Nuclear Information System (INIS)

    Muir, P.; Markel, M.D.; Bogdanske, J.J.; Johnson, K.A.

    1995-01-01

    Dual-energy x-ray absorptiometry was used to measure bone mineral density of four regions in healed femora of nine dogs after fracture fixation with a leg-lengthening plate. Six to 85 months (mean, 46 months) after surgery, the bone mineral density of healed femora was not significantly different from the contralateral uninjured femora (P > .05; power = 0.8 at delta = 15%). Radiolucencies around the proximal screws, apparently associated with screw loosening, were seen on radiographic views of the healed femora of three dogs. In one of these dogs, one screw in the proximal metaphysis had broken. Force-plate analysis of gait was also performed on dogs at the time of bone mineral density measurement. Peak vertical force was decreased in the pelvic limb with the healed fracture compared with the contralateral unoperated limb (P < 0.05). Clinically apparent lameness in three dogs did not appear to be associated with altered bone mineral density and may have been caused by hip osteoarthritis, a nondisplaced hairline diaphyseal fracture, and screw loosening in conjunction with extensive post-traumatic soft tissue injury

  7. Reoperative surgical stabilization of a painful nonunited rib fracture using bone grafting and a metal plate.

    Science.gov (United States)

    Cho, Yang Hyun; Kim, Hyun Koo; Kang, Du-Young; Choi, Young Ho

    2009-09-01

    We report a case of a nonunited sixth rib in a patient with multiple rib fractures who underwent internal fixation using a wire and Judet strut 3 times. During the following 3 years, the patient continued to complain of pain and instability. At surgery, a pseudarthrosis between the ends of the sixth rib was excised. A longitudinal gutter crossing the fracture site was fashioned and splinted with an inlay block of cancellous bone grafted from the iliac crest; stabilization was accomplished with a reconstruction plate and screws. The following 2 years of follow-up demonstrated no instability or pain.

  8. Management of pediatric mandibular fractures using bioresorbable plating system - Efficacy, stability, and clinical outcomes: Our experiences and literature review.

    Science.gov (United States)

    Singh, Mahinder; Singh, R K; Passi, Deepak; Aggarwal, Mohit; Kaur, Guneet

    2016-01-01

    The purpose of this study was to determine the efficacy and stability of the biodegradable fixation system for treatment of mandible fractures in pediatric patients by measuring the bite force. Sixty pediatric patients with mandibular fractures (36 males, 24 females) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 2.5 mm diameter monocortical resorbable screws, 8 mm in length. All patients were followed for 10 months. Clinical parameters, such as soft tissue infection, nonunion, malunion, implant exposure, malocclusion, nerve injury, and bite force for stability, were prospectively assessed. Adequate fixation and primary bone healing was achieved in 100% of the cases. Six minor complications (10%) were observed: 2 soft tissue infections (3%), 1 plate dehiscence (2%), 1 malocclusion (2%), and 2 paresthesia (3%). 2.5-mm resorbable plating system along Champy's line of ideal osteosynthesis is a good treatment modality for mandible fractures in pediatric patients.

  9. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures

    OpenAIRE

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2014-01-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3–12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and...

  10. [Extramedullary fixation combined with intramedullary fixation in the surgical reduction of sagittal mandibular condylar fractures].

    Science.gov (United States)

    Chuanjun, Chen; Xiaoyang, Chen; Jing, Chen

    2016-10-01

    This study aimed to evaluate the clinical effect of extramedullary fixation combined with intramedullary fixation during the surgical reduction of sagittal mandibular condylar fractures. Twenty-four sagittal fractures of the mandibular condyle in18 patients were fixed by two appliances: intramedullary with one long-screw osteosynthesis or Kirschner wire and extramedullary with one micro-plate. The radiologically-recorded post-operative stability-associated com-plications included the screw/micro-plate loosening, micro-plate twisting, micro-plate fractures, and fragment rotation. The occluding relations, the maximalinter-incisal distances upon mouth opening, and the mandibular deflection upon mouth opening were evaluated based on follow-up clinical examination. Postoperative panoramic X-ray and CT scans showed good repositioning of the fragment, with no redislocation or rotation, no screw/plate loosening, and no plate-twisting or fracture. Clinical examination showed that all patients regained normal mandibular movements, ideal occlusion, and normal maximal inter-incisal distances upon mouth opening. Extramedullary fixation combined with intramedullary fixation is highly recommended for sagittal condylar fractures because of the anti-rotation effect of the fragment and the reasonable place-ment of the fixation appliances.

  11. Cannulated screw and cable are superior to modified tension band in the treatment of transverse patella fractures.

    Science.gov (United States)

    Tian, Yun; Zhou, Fang; Ji, Hongquan; Zhang, Zhishan; Guo, Yan

    2011-12-01

    Although the modified tension band technique (eg, tension band supplemented by longitudinal Kirschner wires) has long been the mainstay for fixation of transverse fractures of the patella, it has shortcomings, such as bad reduction, loosening of implants, and skin irritation. We conducted a retrospective comparison of the modified tension band technique and the titanium cable-cannulated screw tension band technique. We retrospectively reviewed 101 patients aged 22 to 85 years (mean, 56.6 years) with AO/OTA 34-C1 fractures (n = 68) and 34-C2 fractures (n = 33). Fifty-two patients were in the modified tension band group and 49 were in the titanium cable-cannulated screw tension band group. Followup was at least 1 year (range, 1-3 years). Comparison criteria were fracture reduction, fracture healing time, and the Iowa score for knee function. The titanium cable-cannulated screw tension band group showed improved fracture reduction, reduced healing time, and better Iowa score, compared with the modified tension band group. In the modified tension band group, eight patients experienced wire migration, three of these requiring a second operation. There were no complications in the titanium cable-cannulated screw tension band group. The titanium cable-cannulated screw tension band technique showed superior results and should be considered as an alternative method for treatment of transverse patellar fractures. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.

  12. The role of 3D plating system in mandibular fractures: A prospective study

    Directory of Open Access Journals (Sweden)

    Rajendra Prasad

    2013-01-01

    Full Text Available Aim: The aim of our study was to evaluate the advantages and disadvantages of 3D plating system in the treatment of mandibular fractures. Patients and Methods: 20 mandibular fractures in 18 patients at various anatomic locations and were treated by open reduction and internal fixation using 3D plates. All patients were followed at regular intervals of 4 th , 8 th and 12 th weeks respectively. Patients were assessed post-operatively for lingual splay and occlusal stability. The incidence of neurosensory deficit, infection, masticatory difficulty, non-union, malunion was also assessed. Results: A significant reduction in lingual splay (72.2% and occlusal stability (72.2% was seen. The overall complication rate was (16.6% which included two patients who developed post-operative paresthesia of lip, three patients had infection and two cases of masticatory difficulty which later subsided by higher antibiotics and 4 weeks of MMF. No evidence of non-union, malunion was noted. Conclusion: A single 3D 2 mm miniplate with 2 mm × 8 mm screws is a reliable and an effective treatment modality for mandibular fracture.

  13. Use of monocortical miniplates for the intraoral treatment of mandibular fractures.

    Science.gov (United States)

    Chiodo, Thomas A; Milles, Maano

    2009-03-01

    Fixation of mandibular fractures using rigid hardware has gained wide acceptance over the past 3 decades. The goal of rigid internal fixation is to allow for fracture healing with limited, or no, time in maxillo-mandibular fixation. There has been significant evolution in plate and screw materials and design over the past 30 years. The term miniplate is used to describe a fracture plate with a screw diameter of 2.0 mm or less. With correct diagnosis and understanding of the forces affecting mandible fractures, miniplates can be applied transorally in various situations, allowing for less invasive treatment with open reduction of mandible fractures. This article describes the use of monocortical miniplates for the intraoral treatment of mandibular fractures.

  14. Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures compared with open technique.

    Science.gov (United States)

    Paredes, Igor; Panero, Irene; Cepeda, Santiago; Castaño-Leon, Ana M; Jimenez-Roldan, Luis; Perez-Nuñez, Ángel; Alén, Jose A; Lagares, Alfonso

    2018-06-14

    This study aimed to compare the accuracy of screw placement between open pedicle screw fixation and percutaneous pedicle screw fixation (MIS) for the treatment of thoracolumbar spine fractures (TSF). Forty-nine patients with acute TSF who were treated with transpedicular screw fixation from January 2013 to December 2016 were retrospectively reviewed. The patients were divided into Open and MIS groups. Laminectomy was performed in either group if needed. The accuracy of the screw placement, the evolution of the Cobb sagital angle postoperatively and at 12-month follow up and the neurological status were recorded. AO type of fracture and TLICS score were also recorded. Mean age was 42 years old. Mean TLICS score was 6,29 and 5,96 for open and MIS groups respectively. Twenty five MIS and 24 open surgeries were performed, and 350 (175 in each group) screws were inserted (7,14 per patient). Twenty-four and 13 screws were considered ̈out ̈ in the open and MIS groups respectively (Odds ratio 1,98. 0,97-4,03 p=0,056). The Cobb sagittal angle went from 13,3o to 4,5o and from 14,9o to 8,2o in the Open and MIS groups respectively (both popen and MIS groups respectively. No neurological worsening was observed. For the treatment of acute thoracolumbar fractures, the MIS technique seems to achieve similar results to the open technique in relation to neurological improvement and deformity correction, while placing the screws more accurately.

  15. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis.

    Science.gov (United States)

    Zhao, Y; Zhang, S; Sun, T; Wang, D; Lian, W; Tan, J; Zou, D; Zhao, Y

    2013-09-01

    To compare the stability of lengthened sacroiliac screw and standard sacroiliac screw for the treatment of unilateral vertical sacral fractures; to provide reference for clinical applications. A finite element model of Tile type C pelvic ring injury (unilateral Denis type II fracture of the sacrum) was produced. The unilateral sacral fractures were fixed with lengthened sacroiliac screw and sacroiliac screw in six different types of models respectively. The translation and angle displacement of the superior surface of the sacrum (in standing position on both feet) were measured and compared. The stability of one lengthened sacroiliac screw fixation in S1 or S2 segment is superior to that of one sacroiliac screw fixation in the same sacral segment. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one sacroiliac screw fixation in S1 and S2 segments respectively. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one lengthened sacroiliac screw fixation in S1 or S2 segment. The stability of one sacroiliac screw fixation in S1 and S2 segments respectively is markedly superior to that of one sacroiliac screw fixation in S1 or S2 segment. The vertical and rotational stability of lengthened sacroiliac screw fixation and sacroiliac screw fixation in S2 is superior to that of S1. In a finite element model of type C pelvic ring disruption, S1 and S2 lengthened sacroiliac screws should be utilized for the fixation as regularly as possible and the most stable fixation is the combination of the lengthened sacroiliac screws of S1 and S2 segments. Even if lengthened sacroiliac screws cannot be systematically used due to specific conditions, one sacroiliac screw fixation in S1 and S2 segments respectively is recommended. No matter which kind of sacroiliac screw is used, if only one screw can be implanted, the fixation in S2 segment is more recommended

  16. Reduction of Zygomatic Fractures Using the Carroll-Girard T-bar Screw.

    Science.gov (United States)

    Baek, Ji Eun; Chung, Chan Min; Hong, In Pyo

    2012-09-01

    Zygomatic fractures are the second most common facial bone fractures encountered and treated by plastic surgeons. Stable fixation of fractured fragments after adequate exposure is critical for ensuring three-dimensional anatomic reduction. Between January 2008 and December 2010, 17 patients with zygomatic fractures were admitted to our hospital; there were 15 male and 2 female patients. The average age of the patients was 41 years (range, 19 to 75 years). We exposed the inferior orbital rim and zygomatic complex through a lateral brow, intraoral, and subciliary incisions, which allowed for visualization of the bone, and then the fractured parts were corrected using the Carroll-Girard T-bar screw. Postoperative complications such as malar asymmetry, diplopia, enophthalmos, and postoperative infection were not observed. Lower eyelid retraction and temporary ectropion occurred in 1 of the 17 patients. Functional and cosmetic results were excellent in nearly all of the cases. In this report, we describe using the Carroll-Girard T-bar screw for the reduction of zygomatic fractures. Because this instrument is easy to use and can rotate to any direction and vector, it can be used to correct displaced zygomatic bone more accurately and safely than other devices, without leaving facial scars.

  17. Radiographic study of the fifth metatarsal for optimal intramedullary screw fixation of Jones fracture.

    Science.gov (United States)

    Ochenjele, George; Ho, Bryant; Switaj, Paul J; Fuchs, Daniel; Goyal, Nitin; Kadakia, Anish R

    2015-03-01

    Jones fractures occur in the relatively avascular metadiaphyseal junction of the fifth metatarsal (MT), which predisposes these fractures to delayed union and nonunion. Operative treatment with intramedullary (IM) screw fixation is recommended in certain cases. Incorrect screw selection can lead to refractures, nonunion, and cortical blowout fractures. A better understanding of the anatomy of the fifth MT could aid in preoperative planning, guide screw size selection, and minimize complications. We retrospectively identified foot computed tomographic (CT) scans of 119 patients that met inclusion criteria. Using interactive 3-dimensional (3-D) models, the following measurements were calculated: MT length, "straight segment length" (distance from the base of the MT to the shaft curvature), and canal diameter. The diaphysis had a lateroplantar curvature where the medullary canal began to taper. The average straight segment length was 52 mm, and corresponded to 68% of the overall length of the MT from its proximal end. The medullary canal cross-section was elliptical rather than circular, with widest width in the sagittal plane and narrowest in coronal plane. The average coronal canal diameter at the isthmus was 5.0 mm. A coronal diameter greater than 4.5 mm at the isthmus was present in 81% of males and 74% of females. To our knowledge, this is the first anatomic description of the fifth metatarsal based on 3-D imaging. Excessive screw length could be avoided by keeping screw length less than 68% of the length of the fifth metatarsal. A greater than 4.5 mm diameter screw might be needed to provide adequate fixation for most study patients since the isthmus of the medullary canal for most were greater than 4.5 mm. Our results provide an improved understanding of the fifth metatarsal anatomy to guide screw diameter and length selection to maximize screw fixation and minimize complications. © The Author(s) 2014.

  18. Hollow Mill for Extraction of Stripped Titanium Screws: An Easy, Quick, and Safe Technique

    OpenAIRE

    Gupta, Ravi; Singh, Harpreet; Singh, Amit; Garg, Sudhir

    2014-01-01

    Removal of jammed titanium screws can be difficult due to the problem of stripping of the hexagonal heads of the screws. We present a technique of extraction of stripped screws with the use of a standard 4.5 mm stainless steel hollow mill in a patient of peri-implant fracture of the radius fixed with a titanium locking plate 2 years back. The technique is quick, safe, and cost effective.

  19. Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study

    Directory of Open Access Journals (Sweden)

    Hadi Mokhtarpour

    2016-07-01

    Full Text Available Background. Fracture load of implant-supported restorations is an important factor in clinical success. This study evaluated the effect of two techniques for screw access hole preparation on the fracture load of cement-screw-retained implant-supported zirconia-based crowns. Methods. Thirty similar cement-screw-retained implant-supported zirconia-based maxillary central incisor crowns were evaluated in three groups of 10. Group NH: with no screw access holes for the control; Group HBS: with screw access holes prepared with a machine before zirconia sintering; Group HAS: with screw access holes prepared manually after zirconia sintering. In group HBS, the access holes were virtually designed and prepared by a computer-assisted design/computer-assisted manufacturing system. In group HAS, the access holes were manually prepared after zirconia sintering using a diamond bur. The dimensions of the screw access holes were equal in both groups. The crowns were cemented onto same-size abutments and were then subjected to thermocycling. The fracture load values of the crowns were measured using a universal testing machine. Data were analyzed with ANOVA and Tukey test (P < 0.05. Results. The mean fracture load value for the group NH was 888.37 ± 228.92 N, which was the highest among the groups, with a significant difference (P < 0.0001. The fracture load values were 610.48 ± 125.02 N and 496.74 ± 104.10 Nin the HBS and HAS groups, respectively, with no significant differences (P = 0.44. Conclusion. Both techniques used for preparation of screw access holes in implant-supported zirconia-based crowns de-creased the fracture load.

  20. Stress corrosion cracking life estimation of hold-down spring screw for nuclear fuel assembly

    International Nuclear Information System (INIS)

    Koh, S.K.

    2005-01-01

    Hold-down spring screw fractures due to primary water stress corrosion cracking were observed in nuclear fuel assemblies. The screw fastens hold-down springs that are required to maintain the nuclear fuel assembly in contact with upper core plate and permit thermal and irradiation-induced length changes. In order to investigate the primary causes of the screw fractures, the finite element stress analysis and fracture mechanics analysis were performed on the hold-down spring assembly. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded the yield strength of the screw material, resulting in local plastic deformation. Preloading on the screw applied for tightening had beneficial effects on the screw strength by reducing the stress level at the critical regions, compared to the screw without preload. Calculated deflections and strains at the hold-down springs using the finite element analysis were in very close agreements with the experimentally measured deflections and strains. Primary water stress corrosion cracking (PWSCC) life of the Inconel 600 screw was predicted by integrating the Scott's model and resulted in a life of 1.42 years, which was fairly close to the field experience. Cracks were expected to originate at the threaded region of the screw and propagated to the opposite side of the spring, which was confirmed by the fractographic analysis of the fractured screws. (orig.)

  1. Combined finite element and multibody musculoskeletal investigation of a fractured clavicle with reconstruction plate

    DEFF Research Database (Denmark)

    Cronskar, Marie; Rasmussen, John; Tinnsten, Mats

    2015-01-01

    This paper addresses the various treatment options for clavicle fractures by means of computational models, more precisely cases with a need for internal fixation: non-unions and certain complex fractures. The motivation for the work is that treatment can be enhanced by a better understanding...... of the loading of the clavicle and fixation device. This study aimed to develop a method for realistic simulation of stresses in the bone and fixation device in the case of a fractured clavicle. A finite element (FE) mesh of the clavicle geometry was created from computer tomography (CT) data and imported...... into the FE solver where the model was subjected to muscle forces and other boundary conditions from a multibody musculoskeletal model performing a typical activity of daily life. A reconstruction plate and screws were also imported into the model. The combination models returned stresses and displacements...

  2. [Application of anterior percutaneous screw fixation in treatment of odontoid process fractures in aged people].

    Science.gov (United States)

    Luo, Peng; Dou, Hai-cheng; Ni, Wen-fei; Huang, Qi-shan; Wang, Xiang-yang; Xu, Hua-zi; Chi, Yong-long

    2011-03-01

    To explore the efficacy of anterior percutaneous screw fixation in the treatment of odontoid process fractures in aged people. From February 2001 to April 2009, 15 elderly patients with odontoid fracture were treated with anterior percutaneous screw fixation,including 13 males and 2 females; the average age was 69.3 years (ranged, 60 to 86 years). According to Anderson classification, there were 10 patients with type II fractures (type II A in 7 cases, type II B in 3 cases, based on Eysel and Roosen classification), 4 patients with shallow type III fractures, 1 patient with deep type III fractures. Thirteen patients were fresh fractures, 2 patients were obsolete fractures. All patients had varying degrees of neck or shoulder pain, and limit activity of neck. There were 4 patients with neural symptoms including 2 grade D and 2 grade C according to Frankel classification. All the patients were followed up and were assessed by radiology. Clinical examination included neck activity, neurological function and the degree of neck pain. Radiology examinations including anteroposterior, lateral, open mouth position and flexion-extension radiographs of cervical vertebra were performed. After surgery, all patients were followed up,and the duration ranged from 6 to 60 months (averaged 31.3 months). Two patients died of other diseases during the follow-up period (18 and 22 months after surgery respectively). All patients got satisfactory results, and all screws were in good position. As the screw was too long, esophagus was compressed by screw tail in one case. One case showed fibrous union, 12 cases had achieved solid bony union, 2 cases showed nonunion without clinical symptoms. The rotation of neck in 3 cases was mildly limited,the neck function of the remaining patients were normal. Four patients with symptoms nerve injuries improved after operation (Frankel E in 3 cases, Frankel D in 1 case). The symptom of neck pain had a significant improvement after surgery (P process

  3. Surgical repair of propagating condylar fractures of the third metacarpal/metatarsal bones with cortical screws placed in lag fashion in 26 racehorses (2007-2015).

    Science.gov (United States)

    Moulin, N; François, I; Coté, N; Alford, C; Cleary, O; Desjardins, M R

    2018-01-19

    Despite the recommendation of plate fixation for propagating condylar fractures of the third metacarpal (McIII) or third metatarsal bone (MtIII), lag screw fixation can be a viable surgical option. To evaluate short-term outcome and long-term racing performance of horses that underwent lag screw fixation of long condylar fractures of the McIII/MtIII. Retrospective case series. Medical records, post-surgical racing performance and outcome of 26 horses with propagating fractures of the medial and/or lateral condyle of McIII/MtIII were reviewed. Medical information included were age, breed, sex, physical examination at admission, circumstances of fracture, radiographic evaluation, anaesthesia and recovery records, surgical and post-operative management, as well as complications. Outcome included racing data and information from telephone interviews. Twenty-six horses (9 Standardbreds and 17 Thoroughbreds) were admitted with a long condylar fracture of the McIII/MtIII. Fore- and hindlimbs were equally represented with the left hindlimb being more frequently involved. Most of the fractures had a spiralling component (76%) and four (15%) were comminuted. Fifteen (58%) horses raced post-surgery including nine Standardbreds (100%) and six Thoroughbreds (35%). Twelve of them were placed in at least one race and 11 won at least once. One horse sustained a severe complication in recovery. No significant difference was observed in the racing performances before and after surgery. Follow-up method and duration were not standardised and there is a low number of cases with six surgeons. Long condylar fractures can be repaired using lag fashion technique combined with a half-limb or full-limb tight cast for recovery as a good surgical alternative. Similar results to plate fixation can be expected, with a return to racing of more than 50%, and the prognosis being even better for pacers. © 2018 EVJ Ltd.

  4. Early Experience with Biodegradable Fixation of Pediatric Mandibular Fractures.

    Science.gov (United States)

    Mazeed, Ahmed Salah; Shoeib, Mohammed Abdel-Raheem; Saied, Samia Mohammed Ahmed; Elsherbiny, Ahmed

    2015-09-01

    This clinical study aims to evaluate the stability and efficiency of biodegradable self-reinforced poly-l/dl-lactide (SR-PLDLA) plates and screws for fixation of pediatric mandibular fractures. The study included 12 patients (3-12 years old) with 14 mandibular fractures. They were treated by open reduction and internal fixation by SR-PLDLA plates and screws. Maxillomandibular fixation was maintained for 1 week postoperatively. Clinical follow-up was performed at 1 week, 6 weeks, 3 months, and 12 months postoperatively. Radiographs were done at 1 week, 3 months, and 12 months postoperatively to observe any displacement and fracture healing. All fractures healed both clinically and radiologically. No serious complications were reported in the patients. Normal occlusion was achieved in all cases. Biodegradable osteofixation of mandibular fractures offers a valuable clinical solution for pediatric patients getting the benefit of avoiding secondary surgery to remove plates, decreasing the hospital stay, further painful procedures, and psychological impact.

  5. [Application of the anatomic plate and trapezoid plate in comminuted intertrochanteric fracture combined with trochanteric coronal position fracture: a controlled clinical trial].

    Science.gov (United States)

    Zhen, Ping; Liu, Xing-Yan; Gao, Ming-Xuan; Tian, Qi

    2010-05-01

    To investigate the therapeutic effect and operative characteristic of the anatomic plate and trapezoid plate for treament of the comminuted intertrochanteric fracture combined with trochanteric coronal position fracture. From Jan. 1998 to Mar. 2007, 57 patients suffered from comminuted intertrochanteric fracture combined with trochanteric coronal position fracture were randomly divided into two groups, 21 patients in trapezoid plate group were treated with the trapezoid compression plate, included 11 males and 10 females with an average age of 41.8 years; and 36 patients in anatomic plate group were treated with the anatomic plate, included 17 males and 19 females with an average age of 42.1 years. All of the 57 fractures were A3 type according to AO classification. The functions of hip joints were evaluated according to the Harris hip functional standard score. All 57 patients were followed-up for 5 months to 9 years and 3 months with an average of 4.8 years. The healing time of the fractures was from 8 to 20 weeks with an average of 12.8 weeks. The results of Harris scoring showed the pain scores of the anatomic plate group were higher than that of the trapezoid plate group (P 0.05). In unstable comminuted intertrochanteric fracture combined with trochanteric coronal position fracture, the lateral wall of trochanteric is often destroyed. The anatomic plate and the trapeziod compression plate can provide effective internal fixation, while many othere internal fixation methods were limited in this kind of fracture. As compared with the anatomic plate fixation, the trapezoid compression plate fixation of comminuted intertrochanteric fracture combined with trochanteric coronal position fracture have several advantages, such as fewer complications, faster union of fracture and earlier recovery of joint functions.

  6. Lag screw fixation of dorsal cortical stress fractures of the third metacarpal bone in 116 racehorses.

    Science.gov (United States)

    Jalim, S L; McIlwraith, C W; Goodman, N L; Anderson, G A

    2010-10-01

    The effectiveness and best method to manage dorsal cortical stress fractures is not clear. This study was performed to evaluate the success of lag screw fixation of such fractures in a population of Thoroughbred racehorses. Lag screw fixation of dorsal cortical stress fractures is an effective surgical procedure allowing racehorses to return to their preoperative level of performance. The records of 116 racehorses (103 Thoroughbreds) admitted to Equine Medical Centre, California between 1986 and 2008 were assessed. Information obtained from medical records included subject details, limb(s) affected, fracture configuration, length of screw used in repair and presence of concurrent surgical procedures performed. Racing performance was evaluated relative to these factors using Fisher's exact test and nonparametric methods with a level of significance of Phorses, 83% raced preoperatively and 83% raced post operatively, with 63% having ≥5 starts. There was no statistically significant association between age, gender, limb affected, fracture configuration or presence of concurrent surgery and likelihood of racing post operatively or of having 5 or more starts. The mean earnings per start and the performance index for the 3 races following surgery were lower compared to the 3 races prior to surgery; however, 29 and 45% of horses either improved or did not change their earnings per start and performance index, respectively. Data show that lag screw fixation is successful at restoring ability to race in horses suffering from dorsal cortical stress fractures. © 2010 EVJ Ltd.

  7. Early results for treatment of two- and three-part fractures of the proximal humerus using Contours PHP (proximal humeral plate).

    Science.gov (United States)

    Biazzo, Alessio; Cardile, Carlo; Brunelli, Luca; Ragni, Paolo; Clementi, Daniele

    2017-04-28

    The management of displaced 2- and 3-part fractures of the proximal humerus is controversial, both in younger and in elderly patients. The purpose of this paper is to evaluate the functional results of the Contours Proximal Humerus Plate (OrthofixR, Bussolengo,Verona, Italy), for the treatment of displaced 2- and 3-part fractures of the proximal humerus. We retrospectively reviewed 55 patients with proximal humerus fractures, who underwent osteosynthesis with Contours Proximal Humerus Plate from December 2011 to March 2015. We had 21 patients with 2-part fractures and with an average age of 67.1 years and 34 patients with 3-part fractures, with average age of 63.6 years. The average union time was 3 months. The mean Constant score was 67 for 2-part fracture group and 64.9 for 3-part fracture group. The difference was not statistically significant (p = 0.18). The overall complication rate was 14.5 %. Six patients underwent additional surgery (10.9%). The most frequent major complication was secondary loss of reduction following varus collapse of the fracture (2 cases). In these patients, there was loss of medial hinge integrity due to impaction and osteoporosis. The placement of the main locking screw in the calcar area to provide inferomedial support is the rational of the Contours Proximal Humerus Plate. Osteosynthesis with Contours Proximal Humerus Plate is a safe system for treating displaced 2- and 3-part fractures of the proximal humerus, with good functional results and complication rates comparable to those reported in the literature.

  8. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.

    Science.gov (United States)

    Malik, Mudasir; Halwai, Manzoor Ahmad

    2014-10-01

    The purpose of this study was to evaluate effectiveness and safety of a relatively new technique of open reduction and internal fixation of displaced transverse patellar fractures with tension band wiring (TBW) through parallel cannulated compression screws. A total of 30 patients with displaced transverse patellar fracture were enrolled in this prospective study. Of the 30 patients, 20 patients had trauma due to fall, 5 due to road traffic accident, 2 due to fall of heavy object on the knee, 2 due to forced flexion of knee, and 1 had fracture due to being beaten. All 30 patients were treated with vertical skin exposure, fracture open reduction, and internal fixation by anterior TBW through 4.0 mm cannulated screws. The postoperative rehabilitation protocol was standardized. The patients were followed postsurgery to evaluate time required for radiographic bone union, knee joint range of motion (ROM), loss of fracture reduction, material failure, and the overall functional result of knee using Bostman scoring. All the fractures healed radiologically, at an average time of 10.7 weeks (range, 8-12 weeks). The average ROM arc was 129.7 degrees (range, 115-140 degrees). No patient had loss of fracture reduction, implant migration, or material failure. The average Bostman score was 28.6 out of 30. Anterior TBW through cannulated screws for displaced transverse fractures is safe and effective alternative treatment. Good functional results and recovery can be expected. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  9. Does a trochanteric lag screw improve fixation of vertically oriented femoral neck fractures? A biomechanical analysis in cadaveric bone.

    Science.gov (United States)

    Hawks, Michael A; Kim, Hyunchul; Strauss, Joseph E; Oliphant, Bryant W; Golden, Robert D; Hsieh, Adam H; Nascone, Jason W; O'Toole, Robert V

    2013-10-01

    We assessed the biomechanical performances of a trochanteric lag screw construct and a traditional inverted triangle construct in the treatment of simulated Pauwels type 3 femoral neck fractures. An inverted triangle construct (three 7.3-mm cannulated screws placed in inverted triangle orientation) and a trochanteric lag screw construct (two 7.3-mm cannulated screws placed across the superior portion of the femoral neck and one 4.5-mm lag screw placed perpendicular to the fracture in superolateral to inferomedial orientation) were tested in nine matched pairs of non-osteoporotic human cadaveric femora. We used a previously described vertically oriented femoral neck fracture model and testing protocol that incrementally loaded the constructs along the mechanical axis of the femur to 1400 N. Specimens that survived incremental loading underwent cyclic loading. Apparent construct stiffness, force at 3mm of displacement, and survival of incremental loading were recorded. The trochanteric lag screw group had a 70% increase in stiffness (261 N/mm [29 standard deviation] versus 153 N/mm [16 standard deviation]; P=0.026) and a 43% increase in force required for displacement (620 N versus 435 N; P=0.018) compared with the inverted triangle group. One trochanteric lag screw and no inverted triangle specimen survived incremental loading. A trochanteric lag screw construct applied to vertically oriented femoral neck fractures provides marked improvement in mechanical performance compared with the inverted triangle construct. © 2013.

  10. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Born, Christopher T. [Temple University Hospital/Temple Children' s Hospital, Temple Sports Medicine, Marlton, NJ (United States); Grudziak, Jan S. [Children' s Hospital of Pittsburgh, Department of Orthopedic Surgery, Pittsburgh, PA (United States); Towbin, Richard B.

    2004-12-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  11. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    International Nuclear Information System (INIS)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D.; Born, Christopher T.; Grudziak, Jan S.; Towbin, Richard B.

    2004-01-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  12. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  13. Simultaneous Middle Third Clavicle Fracture and Type 3 Acromioclavicular Joint Dislocation; A Case Report

    Science.gov (United States)

    Solooki, Saeed; Azad, Ali

    2014-01-01

    Simultaneous middle third clavicle fracture and acromioclavicular joint dislocation is a rare combination injury, as a result of high-energy trauma. We report a patient with a middle third clavicle fracture and ipsilateral grade three-acromioclavicular joint dislocation, which is a rare combination. The patient wanted to get back to work as soon as possible, so the fracture was fixed with reconstruction plate after open reduction and plate contouring; and acromioclavicular joint dislocation was reduced and fixed with two full threaded cancellous screws. One screw was inserted through the plate to the coracoid process. Clinical and radiographic finding revealed complete union of clavicle fracture and anatomical reduction of acromioclavicular joint with pain free full joint range of motion one year after operation. PMID:25207318

  14. Closed External Fixation for Failing or Failed Femoral Shaft Plating in a Developing Country.

    Science.gov (United States)

    Aliakbar, Adil; Witwit, Ibrahim; Al-Algawy, Alaa A Hussein

    2017-08-01

    Femoral shaft fractures are one of the common injuries that is treated by open reduction, with internal fixation by plate and screws or intramedullary nailing, which can achieve a high union rate. To evaluate the outcome of using closed external fixation to augment a failing plate; with signs of screw loosening and increasing bone/plate gap; a failed plate; broken plate; screws completely out of bone with redisplacement of fracture. A retrospective study on 18 patients, aged between 17-42 years, who presented between 6-18 weeks after initial surgical fixation, with pain, difficulty in limb function, deformity and abnormal movement at fracture site, was done. X-Rays showed plating failure with acceptable amount of callus, which unfortunately had refractured. Cases associated with infection and no radiological evidence of callus formation were excluded from this study. Closed reduction was done by manipulation, then fracture fixation by AO external fixator. The patients were encouraged for full weight bearing as early as possible with dynamization later on. Of the 18 patients who underwent external fixation after close reduction, 15 cases showed bone healing in a period between 11-18 weeks (mean of 14.27 weeks) with good alignment (Radiologically). Removal of external fixator was done followed by physical therapy thereafter. Closed external fixation for treatment of failing or failed femoral plating, achieves good success rate and has less complications, is a short time procedure, especially in a hospital with limited resources.

  15. Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients

    Directory of Open Access Journals (Sweden)

    Bhava RJ Satish

    2013-01-01

    Conclusion: Closed reduction and cannulated cancellous screw fixation gives satisfactory functional results in large group of elderly patients. The four quadrant parallel peripheral (FQPP screw fixation technique gives good stability, allows controlled collapse, avoids fixation failure and achieves predictable bone healing in displaced femoral neck fracture in patients ≥50 years of age.

  16. [Curative efficacies of mini-invasive percutaneous osteosynthesis versus supercutaneous plating for distal tibial fractures].

    Science.gov (United States)

    He, Xianfeng; Zhu, Limei; Zhang, Jingwei; Li, Ming; Yu, Yihui

    2014-12-30

    To compare the clinical efficacies of mini-invasive percutaneous osteosynthesis (MIPO) versus supercutaneous plating with closed reduction in the treatment of distal tibial fractures. A total of 48 patients with close distal tibial fractures were treated between January 2010 and January 2012. The MIPO group included 16 males and 8 females with an average age of 36 years. And the types were A (n = 15), B (n = 6) and C (n = 3) according to the classification scheme of Association for the Study of Internal Fixation (AO/ASIF). The supercutaneous plating group also included 16 males and 8 females with an average age of 37 years. And the types were A (n = 15), B (n = 6) and C (n = 3). And the operative duration, hospital stay, union time, postoperative complications and function of ankle were compared between two groups. The mean follow-up period was 18.5 (12-26) months. There was no instance of nonunion, hardware breakdown or deep infection. Patients in supercutaneous plating group had significantly shorter mean operative duration, hospital stay and union time. Three patients and 1 patient in MIPO group presented with superficial infection and delayed union respectively while there was no occurrence in supercutaneous plating group. And the differences were not statistically significant. Fifteen patients (62.5%) complained of implant impingement or discomfort. And stripping occurred at an incidence of 15.6% during the removal time of locking screws in MIPO group. While in supercutaneous plating group, there as no complaint of skin irritation and removal of supercutaneous plate was easily performed without anesthesia. The mean AOFAS score was 90.7 ± 3.8 in supercutaneous plating group versus 88.9 ± 4.1 in MIPO group (P = 0.070). Distal tibia fractures may be treated successfully with MIPO or supercutaneous plating. However, supercutaneous plating offers multiple advantages in terms of mean operative duration, hospital stay, union time, skin irritation and implant

  17. Management of pediatric mandibular fractures using bioresorbable plating system – Efficacy, stability, and clinical outcomes: Our experiences and literature review

    Science.gov (United States)

    Singh, Mahinder; Singh, R.K.; Passi, Deepak; Aggarwal, Mohit; Kaur, Guneet

    2015-01-01

    Aims The purpose of this study was to determine the efficacy and stability of the biodegradable fixation system for treatment of mandible fractures in pediatric patients by measuring the bite force. Methods Sixty pediatric patients with mandibular fractures (36 males, 24 females) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 2.5 mm diameter monocortical resorbable screws, 8 mm in length. All patients were followed for 10 months. Clinical parameters, such as soft tissue infection, nonunion, malunion, implant exposure, malocclusion, nerve injury, and bite force for stability, were prospectively assessed. Results Adequate fixation and primary bone healing was achieved in 100% of the cases. Six minor complications (10%) were observed: 2 soft tissue infections (3%), 1 plate dehiscence (2%), 1 malocclusion (2%), and 2 paresthesia (3%). Conclusion 2.5-mm resorbable plating system along Champy's line of ideal osteosynthesis is a good treatment modality for mandible fractures in pediatric patients. PMID:27195206

  18. Simultaneous of Mid Third Clavicle Fracture and Type 3 Acromioclavicular Joint Dislocation; A Case Report

    Directory of Open Access Journals (Sweden)

    Saeed Solooki

    2014-03-01

    Full Text Available Simultaneous mid third clavicle fracture and acromioclavicular joint dislocation is a rare combination injury, as a result of high-energy trauma. We report a patient with a middle third clavicle fracture and ipsilateral grade three-acromioclavicular joint dislocation, which is a rare combination. The patient wanted to get back to work as soon as possible, so the fracture was fixed with reconstruction plate after open reduction and plate contouring; and acromioclavicular joint dislocation was reduced and fixed with two full threaded cancellous screws. One screw was inserted through the plate to the coracoid process. Clinical and radiographic finding revealed complete union of clavicle fracture and anatomical reduction of acromioclavicular joint with pain free full joint range of motion one year after operation.

  19. Simultaneous of Mid Third Clavicle Fracture and Type 3 Acromioclavicular Joint Dislocation; A Case Report

    Directory of Open Access Journals (Sweden)

    Saeed Solooki

    2014-03-01

    Full Text Available   Simultaneous mid third clavicle fracture and acromioclavicular joint dislocation is a rare combination injury, as a result of high-energy trauma. We report a patient with a middle third clavicle fracture and ipsilateral grade three-acromioclavicular joint dislocation, which is a rare combination. The patient wanted to get back to work as soon as possible, so the fracture was fixed with reconstruction plate after open reduction and plate contouring; and acromioclavicular joint dislocation was reduced and fixed with two full threaded cancellous screws. One screw was inserted through the plate to the coracoid process. Clinical and radiographic finding revealed complete union of clavicle fracture and anatomical reduction of acromioclavicular joint with pain free full joint range of motion one year after operation.

  20. Lateral malleolus hook plate for comminuted Weber A and B fractures: A retrospective study

    Directory of Open Access Journals (Sweden)

    Fang Zhenhua

    2013-01-01

    Full Text Available Background: The goal of managing the comminuted fracture of lateral malleolus is to restore length, rotation and alignment which might be more challenging with extensive comminution around the area of the distal tip. The common osteosynthesis techniques such as the one-third tubular plate, tension band wiring, K-wires, screws, or intramedullary nail may be insufficient in cases with a comminuted lateral malleolus. The anatomical hook plate is an alternative implant in such cases. We present our results of the comminuted lateral malleolar fractures (Weber A, B, managed by open reduction and internal fixation (ORIF with an anatomical hook plate of lateral malleolus (Königsee Implant Company, Germany. Materials and Methods: We retrospectively reviewed 20 patients of comminuted fracture of distal lateral malleolus between 2008 and 2010. There were 12 males and 8 females, right side was involved in 18 patients and left in 2. The mean age was 51.9 years (range 18-75 years. The fractures were categorized by Denis-Weber classification type A (n=1, B1 (n=1, B2 (n=13 and B3 (n=5. Nineteen cases were of closed injury and one of open injury (Gustilo Anderson type II. These patients underwent ORIF with a lateral malleolus anatomical hook plate. Followup including radiographs and clinical examinations were performed. The American Orthopedic Foot and Ankle Society (AOFAS ankle hindfoot scores were documented at followups. Results: The mean followup was 21.4 months (range 16-27 months. The average AOFAS score was 94.3 (range 78-100 points. A stable anatomic reduction and bony union were obtained in all the cases. The average time was 3.1 months (range 2.5-4 months. Four cases had complications like posttraumatic osteoarthritis, hardware impingement and superficial wound infection. Conclusion: A reasonably good stability can be obtained in distal most comminuted fractures of lateral malleolus with a lateral malleolus anatomical hook plate. We believe this

  1. The effects of implant composition on extensor tenosynovitis in a canine distal radius fracture model.

    Science.gov (United States)

    Sinicropi, Stefano M; Su, Brian W; Raia, Frank J; Parisien, May; Strauch, Robert J; Rosenwasser, Melvin P

    2005-03-01

    Dorsal plating of distal radius fractures with titanium plates has resulted in clinically observed tenosynovitis and tendon rupture. The goal of this study was to investigate whether titanium-based implants result in more extensor tendon inflammation than matched stainless-steel implants in a canine fracture model. An osteotomy was created in the distal radius of 18 beagles and fixed with 2.7-mm 4-hole plates composed of commercially pure titanium, titanium alloy (Ti-Al6-V4), or 316L stainless steel. Animals were killed at an average of 4 months. Tendon gliding was assessed by applying a force at the extensor musculotendinous junction and noting gliding. Histologic grading (mild, moderate, severe) was based on cellular hypertrophy, hyperplasia, and leukocytic infiltration. Tendons glided freely in 100% stainless-steel specimens, 75% of titanium alloy, and 43% of commercially pure titanium groups. A severe inflammatory reaction was identified in 60% of the titanium alloy (Ti-A16-V4) group, 57% of the pure titanium group, and 0% of the stainless-steel group. Dorsal plating of the canine radius with commercially pure titanium or titanium alloy implants produced a greater inflammatory peritendinous response than matched stainless-steel implants.

  2. Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation

    Directory of Open Access Journals (Sweden)

    Katonis Pavlos G

    2009-05-01

    Full Text Available Abstract Background Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evaluated in surrogate specimens using an established laboratory model of hip screw cut-out failure. Methods Five dual lag screw implants (Endovis, Citieffe and five single lag screw implants (DHS, Synthes were tested in the Hip Implant Performance Simulator (HIPS of the Legacy Biomechanics Laboratory. This model simulated osteoporotic bone, an unstable fracture, and biaxial rocking motion representative of hip loading during normal gait. All constructs were loaded up to 20,000 cycles of 1.45 kN peak magnitude under biaxial rocking motion. The migration kinematics was continuously monitored with 6-degrees of freedom motion tracking system and the number of cycles to implant cut-out was recorded. Results The dual lag screw implant exhibited significantly less migration and sustained more loading cycles in comparison to the DHS single lag screw. All DHS constructs failed before 20,000 cycles, on average at 6,638 ± 2,837 cycles either by cut-out or permanent screw bending. At failure, DHS constructs exhibited 10.8 ± 2.3° varus collapse and 15.5 ± 9.5° rotation around the lag screw axis. Four out of five dual screws constructs sustained 20,000 loading cycles. One dual screw specimens sustained cut-out by medial migration of the distal screw after 10,054 cycles. At test end, varus collapse and neck rotation in dual screws implants advanced to 3.7 ± 1.7° and 1.6 ± 1.0°, respectively. Conclusion The single and double lag screw implants demonstrated a significantly different migration resistance in surrogate specimens under gait loading simulation with

  3. Osteosynthesis of the first phalanx fractures in horses by means of lag screws

    International Nuclear Information System (INIS)

    Bereznowski, A.; Janicki, A.M.; Sterna, J.

    1996-01-01

    Fractures of the first phalanx belong to the most frequent in horses. Three cases of surgical treatment of first phalanx fractures in horses have been presented. The cases differed by the period of time between the accident and surgical treatment. In all cases osteosynthesis by means of orthopedic screws was applied. In all horses fracture repair was successful, however, not all horses recovered fully enough to return to work. (author)

  4. Biomechanical analysis of the fixation systems for anterior column and posterior hemi-transverse acetabular fractures.

    Science.gov (United States)

    Lei, Jianyin; Dong, Pengfei; Li, Zhiqiang; Zhu, Feng; Wang, Zhihua; Cai, Xianhua

    2017-05-01

    The aim of this study was to evaluate the biomechanical properties of common fixation systems for complex acetabular fractures. A finite element (FE) pelvic model with anterior column and posterior hemi-transverse acetabular fractures was created. Three common fixation systems were used to fix the posterior wall acetabular fractures: 1. Anterior column plate combined with posterior column screws (group I), 2. Anterior column plate combined with quadrilateral area screws (group II) and 3. Double-column plates (group III). And 600 N, representing the body weight, was loaded on the upper surface of the sacrum to simulate the double-limb stance. The amounts of total and relative displacements were compared between the groups. The total amount of displacement was 2.76 mm in group II, 2.81 mm in group III, and 2.83 mm in group I. The amount of relative displacement was 0.0078 mm in group II, 0.0093 mm in group III and 0.014 mm in group I. Our results suggested that all fixation systems enhance biomechanical stability significantly. Anterior column plate combined with quadrilateral area screws has quite comparable results to double column plates, they were superior to anterior column plate combined with posterior screws. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  5. Internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones using bioabsorbable screws.

    Science.gov (United States)

    Mageed, M; Steinberg, T; Drumm, N; Stubbs, N; Wegert, J; Koene, M

    2018-03-01

    Fractures involving the proximal one-third of the splint bone are relatively rare and are challenging to treat. A variety of management techniques have been reported in the literature. The aim of this retrospective case series was to describe the clinical presentation and evaluate the efficacy of bioabsorbable polylactic acid screws in internal fixation of proximal fractures of the 2nd and 4th metacarpal and metatarsal bones in horses. The medical records, diagnostic images and outcome of all horses diagnosed with a proximal fracture of the splint bones and treated with partial resection and internal fixation of the proximal stump using bioabsorbable polylactic acid screws between 2014 and 2015 were reviewed. Eight horses met the inclusion criteria. The results showed that there were no complications encountered during screw placement or postoperatively. Six horses returned to full work 3 months after the operation and two horses remained mildly lame. On follow-up radiographs 12 months postoperatively (n = 2) the screws were not completely absorbed. The screws resulted in a cone-shaped radiolucency, which was progressively replaced from the outer margins by bone sclerosis. The use of bioabsorbable screws for fixation of proximal fractures of the splint bone appears to be a safe and feasible technique and may offer several advantages over the use of traditional metallic implants. © 2018 Australian Veterinary Association.

  6. Degradation behaviour of LAE442-based plate–screw-systems in an in vitro bone model

    International Nuclear Information System (INIS)

    Wolters, Leonie; Besdo, Silke; Angrisani, Nina; Wriggers, Peter; Hering, Britta; Seitz, Jan-Marten; Reifenrath, Janin

    2015-01-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate–screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15 cNm or 7 cNm, NaOH treated plates (15 cNm), magnesium fluoride coated plates (15 cNm) and steel plates as control (15 cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. - Highlights: • Mg-based plate screw systems were examined in an in vitro corrosion setup. • Different screw torques did not affect the corrosion behaviour. • Pretreatment with NaOH showed no increase in corrosion resistance. • Fluoride coating slowed down the corrosion rate of plates. • Fluoride coating might be an alternative for decrease of corrosion rate in vivo

  7. Degradation behaviour of LAE442-based plate–screw-systems in an in vitro bone model

    Energy Technology Data Exchange (ETDEWEB)

    Wolters, Leonie [Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559 Hannover (Germany); Besdo, Silke [Institute of Continuum Mechanics, Leibniz Universität Hannover, Appelstraße 11, 30167 Hannover (Germany); Angrisani, Nina [Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559 Hannover (Germany); Wriggers, Peter [Institute of Continuum Mechanics, Leibniz Universität Hannover, Appelstraße 11, 30167 Hannover (Germany); Hering, Britta [Institute of Production Engineering and Machine Tools, Leibniz Universität Hannover, An der Universität 2, 30823 Garbsen (Germany); Seitz, Jan-Marten [Institute of Materials Science, Leibniz Universität Hannover, An der Universität 2, 30823 Garbsen (Germany); Reifenrath, Janin, E-mail: janin.reifenrath@tiho-hannover.de [Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559 Hannover (Germany)

    2015-04-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate–screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15 cNm or 7 cNm, NaOH treated plates (15 cNm), magnesium fluoride coated plates (15 cNm) and steel plates as control (15 cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. - Highlights: • Mg-based plate screw systems were examined in an in vitro corrosion setup. • Different screw torques did not affect the corrosion behaviour. • Pretreatment with NaOH showed no increase in corrosion resistance. • Fluoride coating slowed down the corrosion rate of plates. • Fluoride coating might be an alternative for decrease of corrosion rate in vivo.

  8. 3D printing-based minimally invasive cannulated screw treatment of unstable pelvic fracture.

    Science.gov (United States)

    Cai, Leyi; Zhang, Yingying; Chen, Chunhui; Lou, Yiting; Guo, Xiaoshan; Wang, Jianshun

    2018-04-04

    Open reduction and internal fixation of pelvic fractures could restore the stability of the pelvic ring, but there were several problems. Minimally invasive closed reduction cannulated screw treatment of pelvic fractures has lots advantages. However, how to insert the cannulated screw safely and effectively to achieve a reliable fixation were still hard for orthopedist. Our aim was to explore the significance of 3D printing technology as a new method for minimally invasive cannulated screw treatment of unstable pelvic fracture. One hundred thirty-seven patients with unstable pelvic fractures from 2014 to 2016 were retrospectively analyzed. Based on the usage of 3D printing technology for preoperative simulation surgery, they were assigned to 3D printing group (n = 65) and control group (n = 72), respectively. These two groups were assessed in terms of operative time, intraoperative fluoroscopy, postoperative reduction effect, fracture healing time, and follow-up function. The effect of 3D printing technology was evaluated through minimally invasive cannulated screw treatment. There was no significant difference in these two groups with respect to general conditions, such as age, gender, fracture type, time from injury to operation, injury cause, and combined injury. Length of surgery and average number of fluoroscopies were statistically different for 3D printing group and the control group (p 3D printing group, versus 22/72 cases (30.6%) scored as excellent and 36/72 cases (50%) as good for the control group. On the other hand, using the Majeed functional scoring criteria, there were 27/65 (41.5%) excellent and 26/65 (40%) good cases for the 3D printing group in comparison to 30/72 (41.7%) and 28/72 (38.9%) cases for the control group, respectively. This suggests no significant difference between these two groups about the function outcomes. Full reduction and proper fixation of the pelvic ring and reconstruction of anatomical morphology are of great

  9. Treatment of Lateral Tibial Condylar Fractures Using Bioactive, Bioresorbable Forged Composites of Raw Particulate Unsintered Hydroxyapatite/Poly-L-Lactide Screws.

    Science.gov (United States)

    Kuroyanagi, Gen; Yoshihara, Hiroyuki; Yamamoto, Naohiro; Suzuki, Hiroyuki; Yamada, Kunio; Yoshida, Yukio; Otsuka, Takanobu; Takada, Naoya

    2018-05-01

    Forged composites of raw particulate unsintered hydroxyapatite/poly-L-lactide (F-u-HA/PLLA) devices possess high mechanical strength, bioactivity, and radio-opacity. The aim of this study was to assess the efficacy of F-u-HA/PLLA screws in the treatment of lateral tibial condylar fractures. From January 2005 to December 2010, a total of 7 patients with displaced closed lateral tibial condylar fractures (Schatzker type II) were treated using F-u-HA/PLLA screws. Open reduction and internal fixation was performed using 2 or 3 F-u-HA/PLLA screws. After surgery, weight bearing was not allowed for 6 weeks. Range of motion exercise was initiated after removal of the plaster splint. Radiographs were evaluated for fracture healing, joint depression, and the radioopacity of F-u-HA/PLLA screws. Clinical outcomes and postoperative complications were also assessed. Average follow-up was 44 months. All fractures were successfully healed. Average values for joint depression were 4.7 mm (range, 2-9 mm) preoperatively, 0.4 mm (range, 0-1 mm) postoperatively, and 0.4 mm (range, 0-1 mm) at final follow-up. Whole shadows of F-u-HA/PLLA screws were observed during the follow-up period. Breakage of screws, osteolysis, and a radiolucent zone around the screws were not observed at final follow-up. Average knee flexion and extension were 134° (range, 110° to 150°) and -1° (range, -10° to 0°), respectively. No patient had wound infection, late aseptic tissue response, or foreign body reaction postoperatively. None of the patients reported pain at final follow-up. These results suggest that F-u-HA/PLLA screws could be an alternative option for the treatment of lateral tibial condylar fractures. [Orthopedics. 2018; 41(3):e365-e368.]. Copyright 2018, SLACK Incorporated.

  10. Immediate percutaneous sacroiliac screw insertion for unstable pelvic fractures: is it safe enough?

    Science.gov (United States)

    Acker, A; Perry, Z H; Blum, S; Shaked, G; Korngreen, A

    2018-04-01

    The purpose of this study was to compare the results of immediate and delayed percutaneous sacroiliac screws surgery for unstable pelvic fractures, regarding technical results and complication rate. Retrospective study. The study was conducted at the Soroka University Medical center, Beer Sheva, Israel, which is a level 1 trauma Center. 108 patients with unstable pelvic injuries were operated by the orthopedic department at the Soroka University Medical Center between the years 1999-2010. A retrospective analysis found 50 patients with immediate surgery and 58 patients with delayed surgery. Preoperative and postoperative imaging were analyzed and data was collected regarding complications. All patients were operated on by using the same technique-percutaneous fixation of sacroiliac joint with cannulated screws. The study's primary outcome measure was the safety and quality of the early operation in comparison with the late operation. A total of 156 sacroiliac screws were inserted. No differences were found between the immediate and delayed treatment groups regarding technical outcome measures (P value = 0.44) and complication rate (P value = 0.42). The current study demonstrated that immediate percutaneous sacroiliac screw insertion for unstable pelvic fractures produced equally good technical results, in comparison with the conventional delayed operation, without additional complications.

  11. CT-guided screw fixation of vertical sacral fractures in local anaesthesia using a standard CT; CT-kontrollierte Schraubenosteosynthese von vertikalen Frakturen des hinteren Beckenringes in Lokalanaesthesie

    Energy Technology Data Exchange (ETDEWEB)

    Reuther, G.; Dehne, I. [Thueringen-Klinik, Saalfeld (Germany). Radiologische Klinik; Roehner, U.; Will, T.; Petereit, U. [Thueringen-Klinik, Saalfeld (Germany). Orthopaedics and Trauma Surgery

    2014-12-15

    To evaluate time efficiency, radiation dose, precision and complications of percutaneous iliosacral screw placement under CT-guidance in local anaesthesia. Retrospective analysis of 143 interventions in 135 patients during a period of 42 months. Implant failures could be evaluated in 85/182 screws and bony healing or refracturing in 46/182 screws. A total of 182 iliosacral screw placements in 179 vertical sacral fractures (105 unilateral, 37 bilateral) took place in 135 patients. 166/179 of the sacral fractures were detected in Denis zone 1, 10 in Denis zone 2 and 3 in Denis zone 3. No screw misplacements including the simultaneous bilateral procedures were noted. The average time for a unilateral screw placement was 23 minutes (range: 14-52 minutes) and 35 minutes (range: 21-60 minutes) for simultaneous bilateral screwing. The dose length product was 365 mGy x cm (range: 162-1014 mGy x cm) for the unilateral and 470 mGy x cm (range: 270-1271 mGy x cm) for the bilateral procedure. 1 gluteal bleeding occurred as the only acute minor complication (0.7%). Fracture healing was verified with follow-up CTs in 42/46 sacral fractures after screw placement. Backing out occurred in 12/85 screws between 6 and 69 days after intervention. In 8 patients contralateral stress fractures were detected after unilateral screw placement between day 10 and 127 (average: 48 days). CT-guided iliosacral screw placement in sacral fractures is a safe tool providing a very high precision. The radiation dose is in the order of a diagnostic CT of the pelvis for both unilateral and bilateral screws. Contralateral stress fractures in unilateral screw placements have to be considered during the first weeks after intervention.

  12. Correlation between femoral offset loss and dynamic hip screw cut-out complications after pertrochanteric fractures: a case-control study.

    Science.gov (United States)

    Boukebous, Baptiste; Guillon, Pascal; Vandenbussche, Eric; Rousseau, Marc Antoine

    2018-04-27

    Screw-plates disassembly incidence after pertrochanteric fracture (PF) amounts to 1 and 16% among the elderly population. The main occurrence is early cervical screw cut-out. The population at highest risk of disassembly remains difficult to identify. The correlation between femoral offset loss and disassembly occurrence has never been surveyed. A radiological prognosis score for screw plate disassembly was defined to reflect trochanteric impaction (TI); it was based on a femoral offset ratio. Our single-centre retrospective case-control study surveyed patients suffering from Dynamic Hip Screw (DHS, Synthes ® ) disassembly following osteosynthesis of non-pathological osteoporotic PF between 2004 and 2014. All cases were categorised by age and gender and paired to three patients in the control group. The primary endpoint was TI measurement, corresponding to offset loss on the operated hip compared to healthy hip offset and expressed as a percentage. The measurement was done on an immediate postoperative X-ray. The secondary endpoints were tip apex distance (TAD) measurement, Ender and AO classifications, as well as postoperative weight-bearing prescription. Twenty-three cases and 69 controls were surveyed. The case group's average age was 87; 70% of the cases were women. The main disassembly occurrence delay was after 27 days. Average TI was 26% within the patients global group and 12% within the control group (p  21%. Using the offset ratio tool, TI measurement was associated with a greater risk of DHS disassembly when it was higher than 21%. The exclusive use of a DHS device does not seem optimal for a TI > 21%. Weight-bearing may be prescribed for all the patients with a TI < 21%, provided good implant positioning is secured.

  13. Wire fixation osteosynthesis for the emergency treatment of patients with mandible fractures: A report of three cases

    Directory of Open Access Journals (Sweden)

    Juan Francisco Oré Acevedo

    2017-06-01

    Full Text Available Introduction: Currently, titanium plates and screws are the gold standard osteosynthesis treatment of facial bone fractures. Techniques considerer obsoletes like surgical wires osteosynthesis are not used anymore, but it is necessary to bear in mind the possibility of using wire for the treatment of cases in emergency, and in which we do not have immediately available sterile implants such as plates and screws. Objectives: Describe the mandibular osteosynthesis with surgical wire as an acceptable surgical treatment when plates and screws are not avaliable. Description: Three cases of patients with mandible fractures were presented, treated on emergency with wire. Two cases were the gunshot injuries and the remaining one suffered a recreational accident. Which required immediate treatment due to the magnitude of the damage, bone exposure and persistence of active bleeding. Conclusions: The use of surgical wire for the treatment of mandibular fractures should not be ignored and is a good alternative for situations where titanium plates and screws are not available due to economic reasons or access. The surgical outcome is stable and allows restoring partially mandibular anatomy and function looking forward a future reconstruction.

  14. Additional Tension Screws Improve Stability in Elastic Stable Intramedullary Nailing: Biomechanical Analysis of a Femur Spiral Fracture Model.

    Science.gov (United States)

    Zachert, Gregor; Rapp, Marion; Eggert, Rebecca; Schulze-Hessing, Maaike; Gros, Nina; Stratmann, Christina; Wendlandt, Robert; Kaiser, Martin M

    2015-08-01

    For pediatric femoral shaft fractures, elastic stable intramedullary nailing (ESIN) is an accepted method of treatment. But problems regarding stability with shortening or axial deviation are well known in complex fracture types and heavier children. Biomechanical in vitro testing was performed to determine whether two modified osteosyntheses with an additional tension screw fixation or screw fixation alone without nails could significantly improve the stability in comparison to classical ESIN. A total of 24 synthetic adolescent-sized femoral bone models (Sawbones, 4th generation; Vashon, Washington, United States) with an identical spiral fracture (length 100 mm) were used. All grafts underwent retrograde fixation with two C-shaped steel nails (2C). Of the 24, 8 osteosyntheses were supported by one additional tension screw (2C1S) and another 8 by two screws (2S) in which the intramedullary nails were removed before testing. Each configuration underwent biomechanical testing in 4-point bending, external rotation (ER) and internal rotation (IR). Furthermore, the modifications were tested in axial physiological 9 degrees position for shifting and dynamic compression as well as dynamic load. Both screw configurations (2C1S and 2S) demonstrated a significantly higher stability in comparison to the 2C configuration in 4-point bending (anterior-posterior, 0.95 Nm/mm [2C] spiral fracture model, the stability of ESIN could be significantly improved by two modifications with additional tension screws. If transferred in clinical practice, these modifications might offer earlier weight bearing and less problems of shortening or axial deviation. Georg Thieme Verlag KG Stuttgart · New York.

  15. Internal fixation of mandibular angle fractures: a meta-analysis.

    Science.gov (United States)

    Regev, Eran; Shiff, Jacob S; Kiss, Alex; Fialkov, Jeffrey A

    2010-06-01

    The degree of rigidity of internal fixation required for the treatment of mandibular angle fractures has long been at the center of debate in the literature. A statistical comparison between rigid fixation and monocortical fixation has been difficult because of multiple terms, definitions, and technical variations. The purpose of this study was to use the meta-analysis tool to combine information from multiple studies and to compare complication rates for different fixation methods. An English language literature search was conducted for articles on mandibular angle fractures. Information was collected on four variables of interest: compression/noncompression technique, monocortical/bicortical screws, number of plates, and location of plates. Five outcome rates were analyzed: infection, reoperation, hardware removal, malunion, and nonunion. Meta-analyses were run using Comprehensive Meta Analysis, version 2.2.03. Twenty-four studies with relevant data on the variables and outcomes of interest met the inclusion criteria. Significantly higher rates of infection, reoperation, and hardware removal were found for compression compared with noncompression, two plates compared with one plate, and for plates located on both the inferior and superior borders as compared with superior or inferior only. There were also significantly higher infection rates for bicortical screws compared with monocortical screws and higher malunion rates for compression compared with noncompression plating techniques. The results of this meta-analysis found lower complication rates with the use of noncompression, monocortical, and single-plate fixation, supporting the trend toward a single, superiorly placed, monocortical miniplate for fixation of mandibular angle fractures.

  16. Isolated tympanic plate fracture frequency and its relationship to mandibular trauma.

    Science.gov (United States)

    Altay, Canan; Erdoğan, Nezahat; Batkı, Ozan; Eren, Erdem; Altay, Sedat; Karasu, Sebnem; Mete, Berna; Uluç, Engin

    2014-11-01

    This study evaluated the prevalence of isolated tympanic fractures and their correlation with mandibular fractures by using maxillofacial computed tomography (CT). We retrospectively evaluated the maxillofacial CT of 1590 patients who presented to our emergency department with maxillofacial trauma between December 2010 and December 2012. Maxillofacial CT was used as the criterion standard for evaluating patients with maxillofacial fractures. The CT images were evaluated by using an electronic picture archiving and communications system and interpreted independently by 2 radiologists. The maxillofacial CT images revealed mandibular fractures in 167 of the patients and isolated tympanic plate fractures in 35 of these 167 patients. Four patients (11%) had a bilateral tympanic plate fracture, and 31 patients (89%) had unilateral tympanic plate fracture. Of all the tympanic plate fractures, 19 (54%) were on the right side and 16 (46%) were on the left side (P > .05). In our results, a significant correlation between the presence of a right-sided tympanic plate fracture and fracture of the ipsilateral condylar process was found (P = .036). However, a statistically significant difference between the presence of a tympanic plate fracture and other mandible fractures, additional soft-tissue findings, or the number of fractures was not determined (P > .05). Sex had no impact on the presence of tympanic plate fracture (P > .05). The frequency of isolated tympanic plate fractures in maxillofacial trauma is low, but it is an important anatomic location. Condyle fractures are significantly associated with isolated tympanic plate fractures. The presence of these injuries should raise suspicion of a concomitant isolated tympanic plate fracture. Copyright © 2014 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  17. Biomechanical analysis of clavicle hook plate implantation with different hook angles in the acromioclavicular joint.

    Science.gov (United States)

    Hung, Li-Kun; Su, Kuo-Chih; Lu, Wen-Hsien; Lee, Cheng-Hung

    2017-08-01

    A clavicle hook plate is a simple and effective method for treating acromioclavicular dislocation and distal clavicle fractures. However, subacromial osteolysis and peri-implant fractures are complicated for surgeons to manage. This study uses finite element analysis (FEA) to investigate the post-implantation biomechanics of clavicle hook plates with different hook angles. This FEA study constructed a model with a clavicle, acromion, clavicle hook plate, and screws to simulate the implantation of clavicle hook plates at different hook angles (90°, 95°, 100°, 105°, and 110°) for treating acromioclavicular joint dislocations. This study investigated the biomechanics of the acromion, clavicle, hook plate, and screws. A smaller hook angle increases the stress on the middle third of the clavicle. A larger hook angle increases the force exerted by the clavicle hook plate on the acromion. The screw at the most medial position on the plate generated the highest stress. The highest stress on the implanted clavicle hook plate was on the turning corner of the hook. A clavicle hook plate with different hook angles may induce different biomechanical behaviors in the clavicle and acromion. Orthopedic surgeons must select a suitable clavicle hook plate based on the anatomical structure of each patient.

  18. A clinical evaluation of a headless, titanium, variable-pitched, tapered, compression screw for repair of nondisplaced lateral condylar fractures in thoroughbred racehorses.

    Science.gov (United States)

    Galuppo, Larry D; Simpson, Edwin L; Greenman, Sylvia L; Dowd, Joseph P; Ferraro, Gregory L; Meagher, Dennis M

    2006-07-01

    To report clinical evaluation of headless compression screws for repair of metacarpal/metatarsal (MC/MT3) condylar fractures in horses. Retrospective case study. Racing Thoroughbreds (n=16) with nondisplaced lateral condylar fractures of MC/MT 3. Medical records (1999-2004) of horses with nondisplaced longitudinal fractures of the lateral condyle of MC/MT3 were reviewed. Pre-operative variables retrieved were: patient age, gender, limb involvement, injury occurrence, fracture length, and width, evidence of palmar comminution and degenerative joint disease, number of pre-injury starts, and pre-injury earnings. Post-operative variables retrieved were: surgical complications, surgical time, number of race starts, and post-operative earnings. MC3 (n=11) and MT3 (5) nondisplaced longitudinal fractures of the lateral condyle were repaired with Acutrak Equine (AE) screws. Left front limb fractures were most common (8) followed by left hind (5) and right front (3). Nine fractures occurred during training and 7 during racing; 4 fractures had palmar comminution. No surgical complications occurred. Of 15 horses that returned to training, 11 (73%) raced 306+/-67 days after injury and had greater mean (+/-SD) post-injury earnings/start ($5290.00+/-$8124.00) than pre-injury ($4971.00+/-$2842.00). Screw removal was not required in any horse. The AE screw is a viable option for repair of nondisplaced lateral condylar MC/MT3 fractures in Thoroughbred racehorses. Adequate stability of nondisplaced lateral condylar fractures can be achieved with a headless tapered compression screw while avoiding impingement on the collateral ligaments and joint capsule of the fetlock joint.

  19. Results of screw fixation combined with cortical drilling for treatment of dorsal cortical stress fractures of the third metacarpal bone in 56 Thoroughbred racehorses

    International Nuclear Information System (INIS)

    Dallap, B.L.; Bramlage, L.R.; Embertson, R.M.

    1999-01-01

    The purpose of this study was to evaluate screw fixation with cortical drilling as a surgical treatment for dorsal cortical stress fractures of MCIII in the Thoroughbred racehorse. Details of age, sex, limb affected, fracture assessment, and post operative recommendations were obtained from medical records and radiographs. Fracture healing was assessed radiographically at the time of screw removal. Performance evaluation was determined from race records obtained from The Jockey Club Information System, Lexington, Kentucky. Fifty-six Thoroughbred racehorses were treated surgically for stress fracture of MCIII with screw fixation and cortical drilling. Stress fractures occurred primarily in the left front limb of the male 3-year-olds, in the dorsolateral cortex of the middle third of MCIII. Ninety-seven percent of the fractures travelled in a dorsodistal to palmaroproximal direction. Median period to screw removal was 2.0 months. Evaluation at time of screw removal revealed 98% of single stress fractures of the left front limb were healed radiographically. Median period to resume training was 2.75 months (single stress fractures); median period to race was 7.62 months. There was no statistically significant difference in earnings/start before and after surgical intervention. Of the 63 fractures treated, two recurred. There were no catastrophic failures, and no incisional infections

  20. Biomechanical and biological aspects of defect treatment in fractures using helical plates.

    Science.gov (United States)

    Perren, S M; Regazzoni, P; Fernandez, A A D

    2014-01-01

    conventional plate is the extent of surgical trauma at the critical site of healing. - Shingling and/or applying an autologous cancellous bone graft: This procedure provides initially no relevant load sharing but will do so after a couple of weeks. The mechanical coupling of the comparably soft graft and the main fracture fragments presents little problems. Applying a cortical bone graft: Such a graft does provide initial only small load sharing and does a less good job inducing callus than a cancellous graft. Furthermore, the coupling by callus between a somewhat rigid bone graft and the mobile main fracture fragments requires a solid maintained contact. If the cortical graft is fixed using implants with small contact area to the graft such as screws or cerclage loops, the local stress may be critical and the graft may break. When the cortical graft is fixed with cerclage wires the procedure must take into account the limited strength of the individual cerclage. Therefore multiple and well-spaced cerclages are required and may lead to success especially if an intramedullary component of the implant contributes to protection (6). The degree of unloading depends apparently on the stiffness of the material of the protecting splint. Though, more important is the effect of the dimensions of the splint. While titanium as a material is about 50% less stiff than steel, the thickness of the implant changes the stiffness with the third power. That is doubling the thickness results in eightfold increased stiffness. When considering the unloading by application of a second plate the leverage of the second plate plays an important role. The larger the distance between the axis of bending and the second implant the larger the protecting effect. The helical plate (2, 3, 7) as introduced by A.A.D. Fernandez offers biological and mechanical advantages. It can be applied without touching the fracture site maintaining the critical biology intact and provides mechanically efficient unloading

  1. Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring

    Directory of Open Access Journals (Sweden)

    Khan I

    2016-07-01

    Full Text Available Aims: To evaluate the effectiveness and safety of anterior tension band wiring technique using two cannulated cancellous screws in patients with transverse (AO34-C1 or transverse with mildly comminuted (AO34-C2 patellar fractures. Materials and Methods: This is a prospective study of 25 patients with transverse fracture or transverse fracture with mildly comminuted patella fractures. All the patients were treated with open reduction and internal fixation using two parallel cannulated screws and 18G stainless steel wire as per the tension band principle. Results: There were eighteen males (72% and seven females (28%. The age group ranged from 24 to 58 years, with mean age of 38 years. The most common mode of injury was fall (72% followed by road traffic accident (20% and violent quadriceps contraction (8%. Transverse fracture was present in 60% and transverse fracture with mild comminution in 40% of patients. Mean time to achieve union was 10.7 weeks (range 8-12 weeks. Mean ROM at three months was 113.8 degree (90-130 and at final follow up this improved to 125.4 degrees (range 100-140. There was one case of knee stiffness and no case of implant failure was observed. Patients were evaluated using Bostman scoring, the mean score at three months being 26.04 which improved to 27.36 at the end of final follow up at one year. Conclusion: Cannulated cancellous screws with anterior tension band wiring is a safe, reliable and reproducible method in management of transverse patellar fractures, with less chances of implant failure and soft tissue irritation.

  2. Comparison of the Mechanical Characteristics of a Universal Small Biplane Plating Technique Without Compression Screw and Single Anatomic Plate With Compression Screw.

    Science.gov (United States)

    Dayton, Paul; Ferguson, Joe; Hatch, Daniel; Santrock, Robert; Scanlan, Sean; Smith, Bret

    2016-01-01

    To better understand the mechanical characteristics of biplane locked plating in small bone fixation, the present study compared the stability under cyclic cantilever loading of a 2-plate locked biplane (BPP) construct without interfragmentary compression with that of a single-plate locked construct with an additional interfragmentary screw (SPS) using surrogate bone models simulating Lapidus arthrodesis. In static ultimate plantar bending, the BPP construct failed at significantly greater load than did the SPS construct (556.2 ± 37.1 N versus 241.6 ± 6.3 N, p = .007). For cyclic failure testing in plantar bending at a 180-N starting load, the BPP construct failed at a significantly greater number of cycles (158,322 ± 50,609 versus 13,718 ± 10,471 cycles) and failure load (242.5 ± 25.0 N versus 180.0 ± 0.0 N) than the SPS construct (p = .002). For cyclic failure testing in plantar bending at a 120-N starting load, the results were not significantly different between the BPP and SPS constructs for the number of cycles (207,646 ± 45,253 versus 159,334 ± 69,430) or failure load (205.0 ± 22.4 N versus 185.0 ± 33.5 N; p = .300). For cyclic testing with 90° offset loading (i.e., medial to lateral bending) at a 120-N starting load, all 5 BPP constructs (tension side) and 2 of the 5 SPS constructs reached 250,000 cycles without failure. Overall, the present study found the BPP construct to have superior or equivalent stability in multiplanar orientations of force application in both static and fatigue testing. Thus, the concept of biplane locked plating, using 2 low profile plates and unicortical screw insertion, shows promise in small bone fixation, because it provides consistent stability in multiplanar orientations, making it universally adaptable to many clinical situations. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Advantage and limitations of a minimally-invasive approach and early weight bearing in the treatment of tibial shaft fractures with locking plates.

    Science.gov (United States)

    Adam, P; Bonnomet, F; Ehlinger, M

    2012-09-01

    Intramedullary nailing is a common method of treating tibial shaft fractures. However, precise control of reduction at the proximal and distal quarters is difficult to achieve. The purpose of this study was to assess the results of plating using locking screws and the feasibility of a minimally-invasive approach. All patients with tibial shaft fracture treated by means of locking plates from January 2004 to October 2006. Thirty-two fractures were treated in 32 patients with a mean age of 43.8 years. Internal fixation with a locking plate and screw construct, using a minimally-invasive or standard approach. Surgical approach, time to weight bearing, complications and their type, time to bone union, alignment in the frontal and sagittal planes on anteroposterior and lateral radiographs. The minimally-invasive approach was performed in 28 cases and immediate full weight bearing allowed in 25 cases. At a mean follow-up of 27 months, two patients had died and two patients were lost to follow-up. The mean time to bone union was 9.1 weeks. Four cases had a complicated course: one infection, one compartment syndrome, one hardware breakage and one pseudarthrosis. Six cases ended up with valgus malunion exceeding 5° in the frontal plane, already present at the time of surgery. Where a minimally-invasive approach can be performed, immediate pain-free weight bearing can be allowed without further displacement at follow-up. The observed rate of malunion underlines the need for adequate reduction and shows that the rationale for success does not solely depend on the plate anatomic design but also on the skills of the operating surgeon. Level I university regional hospital Cohort study. Copyright © 2012. Published by Elsevier Masson SAS.

  4. Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography.

    Science.gov (United States)

    Endo, Jun; Yamaguchi, Satoshi; Saito, Masahiko; Morikawa, Tsuguo; Akagi, Ryuichiro; Sasho, Takahisa

    2016-10-01

    To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. The mean anterior tibiofibular distance was 0.7mm after syndesmotic fixation. It increased to 1.9mm at one year after screw removal (p=0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1mm vs. 0.6mm for the posterior tibiofibular distance, 0.2mm vs. 0.3mm for the anteroposterior fibular translation, and 0.7° vs. 0° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction, ranging from 10% to 50% after syndesmotic fixation (p=0.01) and from 20% to 60% at one year after screw removal (p=0.02). The anterior tibiofibular distance widened after one year of syndesmotic screw removal. The incidence of malreduction varied depending on the measurement method. Copyright © 2016. Published by Elsevier Ltd.

  5. New technique for fixing rib fracture with bioabsorbable plate.

    Science.gov (United States)

    Oyamatsu, Hironori; Ohata, Norihisa; Narita, Kunio

    2016-09-01

    Fixation of a bone fracture with a bioabsorbable plate made of poly-L-lactide and hydroxyapatite has received attention. We adopted this technique for a rib fracture by bending the plate into a U-shape and fixing it with suture through the holes in the mesh of the plate and holes that are drilled in the edge of the fractured rib. The suture is also wound around the plate. © The Author(s) 2016.

  6. Cost-Utility Analysis of Pedicle Screw Removal After Successful Posterior Instrumented Fusion in Thoracolumbar Burst Fractures.

    Science.gov (United States)

    Lee, Han-Dong; Jeon, Chang-Hoon; Chung, Nam-Su; Seo, Young-Wook

    2017-08-01

    A cost-utility analysis (CUA). The aim of this study was to determine the cost-effectiveness of pedicle screw removal after posterior fusion in thoracolumbar burst fractures. Pedicle screw instrumentation is a standard fixation method for unstable thoracolumbar burst fracture. However, removal of the pedicle screw after successful fusion remains controversial because the clinical benefits remain unclear. CUA can help clinicians make appropriate decisions about optimal health care for pedicle screw removal after successful fusion in thoracolumbar burst fractures. We conducted a single-center, retrospective, longitudinal matched-cohort study of prospectively collected outcomes. In total, 88 consecutive patients who had undergone pedicle screw instrumentation for thoracolumbar burst fracture with successful fusion confirmed by computed tomography (CT) were used in this study. In total, 45 patients wanted to undergo implant removal surgery (R group), and 43 decided not to remove the implant (NR group). A CUA was conducted from the health care perspective. The direct costs of health care were obtained from the medical bill of each patient. Changes in health-related quality of life (HRQoL) scores, validated by Short Form 6D, were used to calculate quality-adjusted life-years (QALYs). Total costs and gained QALY were calculated at 1 year (1 year) and 2 years (2 years) compared with baseline. Results are expressed as an incremental cost-effectiveness ratio (ICER). Different discount rates (0%, 3%, and 5%) were applied to both cost and QALY for sensitivity analysis. Baseline patient variables were similar between the two groups (all P > 0.05). The additional benefits of implant removal (0.201 QALY at 2 years) were achieved with additional costs ($2541 at 2 years), equating to an ICER of $12,641/QALY. On the basis of the different discount rates, the robustness of our study's results was also determined. Implant removal after successful fusion in a thoracolumbar burst

  7. A biomechanical comparison of headless tapered variable pitch and AO cortical bone screws for fixation of a simulated slab fracture in equine third carpal bones.

    Science.gov (United States)

    Bueno, Aloisio C D; Galuppo, Larry D; Taylor, Kenneth T; Jensen, David G; Stover, Susan M

    2003-01-01

    To compare the mechanical shear strengths and stiffnesses obtained from in vitro testing of a simulated complete third carpal bone (C3) frontal plane radial facet slab fracture (osteotomy) stabilized with either a 4/5 Acutrak (AT) compression screw or a 4.5-mm AO cortical bone (AO) screw inserted in lag fashion. Drilling, tapping, and screw insertion torques, forces, and times also were compared between AT and AO implants. In vitro biomechanical assessment of site preparation, screw insertion, and shear failure test variables of bone screw stabilized simulated C3 slab fracture in paired cadaveric equine carpi. Eight pairs of cadaveric equine C3 without orthopedic abnormalities. Standardized simulated C3 slab fractures were repaired with either AO or AT screws (AO/C3 and AT/C3 groups, respectively). Drilling, tapping, and screw insertion torques, forces, and times were measured with a materials testing machine for each screw type. Repaired specimens were tested in axially oriented shear until failure. Paired Students t-tests were used to assess differences between site preparation, screw insertion, and shear testing variables. Significance was set at P bone fragment measurements of the standardized simulated C3 slab fractures created for AO or AT screws. There were no significant differences for mean and maximum drilling torques; however, the tapered AT drill had greater maximum drilling force compared with the 3.2-mm and 4.5-mm AO drill bits. Mean insertion torque and force measured from the self-tapping AT screw were not significantly different compared with the 4.5-mm AO tap. There were no significant differences in maximum screw torque among constructs. Total procedure time was significantly longer for the AT group (5.8 +/- 1.6 minutes) compared with the AO group (2.9 +/- 1.1 minutes; P =.001). AT stabilized specimens had significantly greater mean +/- SD initial shear stiffness (3.64 +/- 1.08 kN/mm) than AO specimens (1.64 +/- 0.73 kN/mm; P =.005). All other

  8. Causes and treatments of lag screw's cut out after intramedullary nailing osteosinthesis for trochanteric fractures.

    Science.gov (United States)

    Gazzotti, Gabriele; Matino, Giovanni; Tsatsis, Christos; Sacchetti, GianLuigi; Baudi, Paolo; Catani, Fabio

    2014-08-20

    Background. Superior cut-out of a lag screw remains a serious complication in the treatment of trochanteric or subtrochanteric fractures and it is related to many factors: the type of fracture, osteoporosis and the stability of fracture reduction. Little is known about the outcome after revision surgery for complications of the gamma nail. We assessed the outcome in patients who had revision surgery because of lag screw's cut out after gamma nailing for a trochanteric fracture.Material and Method. We present a study of 20 consecutive patients who underwent treatment after 20 cut-out of the lag screw fixation of a trochanteric fracture with Gamma Locking Nail from September 2004 to November 2010. In 16 patients hip prothesis was performed, in 1 the removal of the implant and in 3 the reosteosynthesis. We reviewed 13 patients: 10 total hip arthroplasty, 2 endoprothesis and 1 reosteosynthesis of nail and lag screw (mean follow up: 26 months, mean age: 73 years old), 7 patients died. Patients were reviewed retrospectively by an independent observer. Clinical evaluation was performed, Oxford score and Harris Hip score were measured. X-Ray examination was performed after a minimum of 12 months of follow up.Results. Mean Harris Hip Score mean was 67 and mean Oxford score was 32 in hip prothesis group (12 patients). We had several complications, Implant-related complications were: 2 ipometria > 2cm, 2 recurrent hip arthroplasty dislocations (1 reoperated), 4 persistent thigh pain. In only 4 patients none complications were observed. Another patient,  who had been subjected to reosteosinthesis, obtained better results (HHS:95, Oxford score:45) but with a 2 cm ipometria and occasional pain in the thigh.Conclusion. Cut out after gamma nail is consequent to biological or mechanical causes. Treatment of this complication is hip prosthesis (parzial or total hip arthroplasty), reosteosynthesis of the lag screw and/or the nail and the removal of the implant. Conversion to total

  9. Self-reinforced bioresorbable poly-L/DL-lactide [SR-P(L/DL)LA] 70/30 miniplates and miniscrews are reliable for fixation of anterior mandibular fractures: a pilot study.

    Science.gov (United States)

    Ylikontiola, Leena; Sundqvuist, Kai; Sàndor, George K B; Törmälä, Pertti; Ashammakhi, Nureddin

    2004-03-01

    Bioresorbable osteofixation devices are being increasingly used in orthognathic surgery and in cases of trauma to avoid problems associated with conventional metal osteofixation devices. The aim of this clinical study was to assess the reliability and efficacy of bioresorbable self-reinforced poly-L/DL-lactide (SR-P(L/DL)LA 70/30) plates and screws in the fixation of mandibular fractures in adults. Ten patients (20 to 49 years old) with isolated anterior mandibular parasymphyseal fractures were treated by means of open reduction and internal fixation using SR-P(L/DL)LA 70/30 bioresorbable plates and screws. During the minimum of 6 months of follow-up, no problems were encountered except for 1 case where a plate became exposed intraorally and infected. This required debridement and later excision of the exposed part of the plate. Despite this setback the fractured bone healed well. SR-P(L/DL)LA 70/30 plates and screws are reliable for internal fixation of anterior mandibular fractures in adults. Proper soft tissue coverage should be ensured to avoid plate exposure. Should implant exposure occur, it might be necessary to excise the exposed part after fracture healing (6-8 weeks postoperatively).

  10. [The Postero-Lateral Approach--An Alternative to Closed Anterior-Posterior Screw Fixation of a Dislocated Postero-Lateral Fragment of the Distal Tibia in Complex Ankle Fractures].

    Science.gov (United States)

    von Rüden, C; Hackl, S; Woltmann, A; Friederichs, J; Bühren, V; Hierholzer, C

    2015-06-01

    The dislocated posterolateral fragment of the distal tibia is considered as a key fragment for the successful reduction of comminuted ankle fractures. The reduction of this fragment can either be achieved indirectly by joint reduction using the technique of closed anterior-posterior screw fixation, or directly using the open posterolateral approach followed by plate fixation. The aim of this study was to compare the outcome after stabilization of the dislocated posterolateral tibia fragment using either closed reduction and screw fixation, or open reduction and plate fixation via the posterolateral approach in complex ankle fractures. In a prospective study between 01/2010 and 12/2012, all mono-injured patients with closed ankle fractures and dislocated posterolateral tibia fragments were assessed 12 months after osteosynthesis. Parameters included: size of the posterolateral tibia fragment relative to the tibial joint surface (CT scan, in %) as an indicator of injury severity, unreduced area of tibial joint surface postoperatively, treatment outcome assessed by using the "Ankle Fracture Scoring System" (AFSS), as well as epidemiological data and duration of the initial hospital treatment. In 11 patients (10 female, 1 male; age 51.6 ± 2.6 years [mean ± SEM], size of tibia fragment 42.1 ± 2.5 %) the fragment fixation was performed using a posterolateral approach. Impaired postoperative wound healing occurred in 2 patients of this group. In the comparison group, 12 patients were treated using the technique of closed anterior-posterior screw fixation (10 female, 2 male; age 59.5 ± 6.7 years, size of tibia fragment 45.9 ± 1.5 %). One patient of this group suffered an incomplete lesion of the superficial peroneal nerve. Radiological evaluation of the joint surface using CT scan imaging demonstrated significantly less dislocation of the tibial joint surface following the open posterolateral approach (0.60 ± 0.20 mm) compared to the closed

  11. [Clinical application of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nail].

    Science.gov (United States)

    Zhu, Hai-Bing; Wu, Li-Guo; Fang, Zhi-Song; Luo, Cong-Feng; Wang, Qing-Feng; Ma, Yi-Ping; Gao, Hong; Fu, Guo-Hai; Hu, Cheng-Ting

    2012-07-01

    To introduce the clinical method of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nails. From June 2006 to March 2011, 26 patients with distal tibial fracture were treated with interlocking intramedullary nails using blocking screws and rooting technique, included 18 males and 8 females with an average age of 46.2 years old ranging from 24 to 64 years. According to AO classification: 10 cases of type A1, 4 cases of type A2, 8 cases of type B1, 4 cases of type B2. The average distance of the fractures end to the ankle joint was 85 mm ranging from 55 to 125 mm, the mean time between injured and operation was 4.5 days. The patients were evaluated with pain, range of motion, walking. All cases were followed-up for 6 to 22 months (averaged 15 months). According to Iowa ankle joint grading system,the score was improved from preoperative (66.8 +/- 8.2) to postoperative (94.6 +/- 4.8). All fractures had united, and got satisfactory reduction and stable fixation with no complications had happen such as breakage of screw. Fixation with interlocking intramedullary nail using blocking screws and rooting technique in treating distal tibial fracture, is a safe and effective technique for the improvement of stability.

  12. A customized fixation plate with novel structure designed by topological optimization for mandibular angle fracture based on finite element analysis.

    Science.gov (United States)

    Liu, Yun-Feng; Fan, Ying-Ying; Jiang, Xian-Feng; Baur, Dale A

    2017-11-15

    The purpose of this study was to design a customized fixation plate for mandibular angle fracture using topological optimization based on the biomechanical properties of the two conventional fixation systems, and compare the results of stress, strain and displacement distributions calculated by finite element analysis (FEA). A three-dimensional (3D) virtual mandible was reconstructed from CT images with a mimic angle fracture and a 1 mm gap between two bone segments, and then a FEA model, including volume mesh with inhomogeneous bone material properties, three loading conditions and constraints (muscles and condyles), was created to design a customized plate using topological optimization method, then the shape of the plate was referenced from the stress concentrated area on an initial part created from thickened bone surface for optimal calculation, and then the plate was formulated as "V" pattern according to dimensions of standard mini-plate finally. To compare the biomechanical behavior of the "V" plate and other conventional mini-plates for angle fracture fixation, two conventional fixation systems were used: type A, one standard mini-plate, and type B, two standard mini-plates, and the stress, strain and displacement distributions within the three fixation systems were compared and discussed. The stress, strain and displacement distributions to the angle fractured mandible with three different fixation modalities were collected, respectively, and the maximum stress for each model emerged at the mandibular ramus or screw holes. Under the same loading conditions, the maximum stress on the customized fixation system decreased 74.3, 75.6 and 70.6% compared to type A, and 34.9, 34.1, and 39.6% compared to type B. All maximum von Mises stresses of mandible were well below the allowable stress of human bone, as well as maximum principal strain. And the displacement diagram of bony segments indicated the effect of treatment with different fixation systems. The

  13. Outcomes of osteoporotic trochanteric fractures treated with cement-augmented dynamic hip screw

    Science.gov (United States)

    Gupta, Rakesh Kumar; Gupta, Vinay; Gupta, Navdeep

    2012-01-01

    Background: Dynamic hip screw (DHS) has been the standard treatment for stable trochanteric fracture patterns, but complications of lag screw cut out from a superior aspect, due to inadequate bone anchorage, occur frequently in elderly osteoporotic patients. Polymethylmethacrylate (PMMA) has been used as an augmentation tool to facilitate fixation stability in cadaveric femora for biomechanical studies and in pathological fractures. However, there are very few reports on the utilization of PMMA cement to prevent these complications in fresh intertrochanteric fractures. A prospective study was conducted to evaluate the outcome and efficacy of PMMA augmented DHS in elderly osteoporotic patients with intertrochanteric fractures. Materials and Methods: The study included 64 patients (AO type31-A2.1 in eight, A2.2 in 29, A2.3 in 17 patients, and 31-A3.1 in five, A3.2 in three, and A3.3 in two patients) with an average age of 72 years (60 – 94 years) of which 60 were available for final followup. PMMA augmentation of DHS was performed in all cases by injecting PMMA cement into the femoral head with a custommade gun designed by the authors. The clinical outcome was rated as per the Salvati and Wilson scoring system at the time of final followup of one year. Results were graded as excellent (score > 31), good (score 24 – 31), fair (score 16 – 23), and poor (score < 16). Results: Fracture united in all patients and the average time to union was 13.8 weeks (range 12 – 16 weeks). At an average followup of 18 months (range 12 – 24 months), no incidence of varus collapse or superior screw cut out was observed in any of the patients in spite of weightbearing ambulation from the early postoperative period. There was no incidence of avascular necrosis (AVN) or cement penetration into the joint in our series. Most of the patients were able to regain their prefracture mobility status with a mean hip pain score of 8.6. Conclusion: Cement augmentation of DHS appears to be an

  14. Outcomes of osteoporotic trochanteric fractures treated with cement-augmented dynamic hip screw

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar Gupta

    2012-01-01

    Full Text Available Background: Dynamic hip screw (DHS has been the standard treatment for stable trochanteric fracture patterns, but complications of lag screw cut out from a superior aspect, due to inadequate bone anchorage, occur frequently in elderly osteoporotic patients. Polymethylmethacrylate (PMMA has been used as an augmentation tool to facilitate fixation stability in cadaveric femora for biomechanical studies and in pathological fractures. However, there are very few reports on the utilization of PMMA cement to prevent these complications in fresh intertrochanteric fractures. A prospective study was conducted to evaluate the outcome and efficacy of PMMA augmented DHS in elderly osteoporotic patients with intertrochanteric fractures. Materials and Methods: The study included 64 patients (AO type31-A2.1 in eight, A2.2 in 29, A2.3 in 17 patients, and 31-A3.1 in five, A3.2 in three, and A3.3 in two patients with an average age of 72 years (60 − 94 years of which 60 were available for final followup. PMMA augmentation of DHS was performed in all cases by injecting PMMA cement into the femoral head with a custommade gun designed by the authors. The clinical outcome was rated as per the Salvati and Wilson scoring system at the time of final followup of one year. Results were graded as excellent (score > 31, good (score 24 − 31, fair (score 16 − 23, and poor (score < 16. Results: Fracture united in all patients and the average time to union was 13.8 weeks (range 12 − 16 weeks. At an average followup of 18 months (range 12 − 24 months, no incidence of varus collapse or superior screw cut out was observed in any of the patients in spite of weightbearing ambulation from the early postoperative period. There was no incidence of avascular necrosis (AVN or cement penetration into the joint in our series. Most of the patients were able to regain their prefracture mobility status with a mean hip pain score of 8.6. Conclusion: Cement augmentation of DHS appears

  15. Percutaneous Screw Fixation of Distal Tibia Fractures – Functional Results in Sixteen Patients

    OpenAIRE

    Kaftandziev, Igor; Trpeski, Simon; Arsovski, Oliver; Spasov, Marko

    2014-01-01

    INTRODUCTION: An important feature of distal tibia fractures is the relevance of the soft tissue coverage. In order to maintain good functional outcome, several operative techniques have been established. Among them, percutaneous screw fixation has the advantage of causing less biological damage of the soft tissues with lower rates of complications. MATERIAL AND METHODS: We reviewed 16 patients with distal tibia fracture. Operative treatment consisted of indirect reduction and percutaneou...

  16. Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Li Xinning

    2010-08-01

    Full Text Available Abstract Hip fractures are a common injury among the elderly. Internal fixation with an intramedullary (IM system has gained popularity for the treatment of intertrochanteric femur fractures. Multiple complications associated with IM fracture fixation have been described, however, we report a rare complication of medial pelvic migration of the lag screw of a short IM nail in a stable construct ten weeks post surgery. The patient was subsequently treated with Lag Screw removal and revision surgery with a shorter Lag Screw and an accessory cannulated screw acting as a de-rotational device. The patient did well with the revision surgery and was able to return to full activities.

  17. Compressive forces achieved in simulated equine third metacarpal bone lateral condylar fractures of varying fragment thickness with Acutrak Plus screw and 4.5 mm AO cortical screws.

    Science.gov (United States)

    Lewis, Andrew J; Sod, Gary A; Burba, Daniel J; Mitchell, Colin F

    2010-01-01

    To compare compression pressure (CP) of 6.5 mm Acutrak Plus (AP) and 4.5 mm AO cortical screws (AO) when inserted in simulated lateral condylar fractures of equine 3rd metacarpal (MC3) bones. Paired in vitro biomechanical testing. Cadaveric equine MC3 bones (n=12 pair). Complete lateral condylar osteotomies were created parallel to the midsagittal ridge at 20, 12, and 8 mm axial to the epicondylar fossa on different specimens grouped accordingly. Interfragmentary compression was measured using a pressure sensor placed in the fracture plane before screw placement for fracture fixation. CP was acquired and mean values of CP for each fixation method were compared between the 6.5 mm (AP) and 4.5 mm (AO) for each group using a paired t-test within each fracture fragment thickness group with statistical significance set at Pfractures, especially complete fractures. Because interfragmentary compression plays a factor in the overall stability of a repair, it is recommended for use only in patients with thin lateral condyle fracture fragments, as the compression tends to decrease with an increase in thickness.

  18. Comparison of skeletal stability after sagittal split ramus osteotomy among mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation using absorbable plates and screws.

    Science.gov (United States)

    Ueki, Koichiro; Moroi, Akinori; Yoshizawa, Kunio; Hotta, Asami; Tsutsui, Takamitsu; Fukaya, Kenichi; Hiraide, Ryota; Takayama, Akihiro; Tsunoda, Tatsuta; Saito, Yuki

    2017-02-01

    The purpose of this study was to examine skeletal stability and plate breakage after sagittal split ramus osteotomy (SSRO) with the mono-cortical plate fixation, bi-cortical plate fixation, and hybrid fixation techniques using absorbable plates and screws. A total of 76 Japanese patients diagnosed with mandibular prognathism with and without maxillary deformity were divided into 3 groups randomly. A total of 28 patients underwent SSRO with mono-cortical plate fixation, 23 underwent SSRO with bi-cortical plate fixation, and 25 underwent SSRO with hybrid fixation. Skeletal stability and horizontal condylar angle were analyzed by axial, frontal, and lateral cephalograms from before the operation to 1 year postoperatively. Breakage of the plate and screws was observed by 3-dimensional computed tomography (3DCT) immediately after surgery and after 1 year. Although there was a significant difference between the mono-cortical plate fixation group and hybrid fixation group regarding right MeAg in T1 (P = 0.0488) and occlusal plane in T1 (P = 0.0346), there were no significant differences between the groups for the other measurements in each time interval. In 2 cases, namely, 6 sides in the mono-cortical plate fixation group, breakage of the absorbable plate was found by 3DCT. However, there was no breakage in the bi-cortical plate fixation group and hybrid fixation group. This study results suggested that there were no significant differences in the postoperative skeletal stability among the 3 groups, and bi-cortical fixation as well as hybrid fixation was a reliable and useful method to prevent plate breakage even if an absorbable material was used. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  19. Effect of diameter of the drill hole on torque of screw insertion and pushout strength for headless tapered compression screws in simulated fractures of the lateral condyle of the equine third metacarpal bone.

    Science.gov (United States)

    Carpenter, Ryan S; Galuppo, Larry D; Stover, Susan M

    2006-05-01

    To compare variables for screw insertion, pushout strength, and failure modes for a headless tapered compression screw inserted in standard and oversize holes in a simulated lateral condylar fracture model. 6 pairs of third metacarpal bones from horse cadavers. Simulated lateral condylar fractures were created, reduced, and stabilized with a headless tapered compression screw by use of a standard or oversize hole. Torque, work, and time for drilling, tapping, and screw insertion were measured during site preparation and screw implantation. Axial load and displacement were measured during screw pushout. Effects of drill hole size on variables for screw insertion and screw pushout were assessed by use of Wilcoxon tests. Drill time was 59% greater for oversize holes than for standard holes. Variables for tapping (mean maximum torque, total work, positive work, and time) were 42%, 70%, 73%, and 58% less, respectively, for oversize holes, compared with standard holes. Variables for screw pushout testing (mean yield load, failure load, failure displacement, and failure energy) were 40%, 40%, 47%, and 71% less, respectively, for oversize holes, compared with standard holes. Screws could not be completely inserted in 1 standard and 2 oversize holes. Enlarging the diameter of the drill hole facilitated tapping but decreased overall holding strength of screws. Therefore, holes with a standard diameter are recommended for implantation of variable pitch screws whenever possible. During implantation, care should be taken to ensure that screw threads follow tapped bone threads.

  20. History of internal fixation with plates (part 2): new developments after World War II; compressing plates and locked plates.

    Science.gov (United States)

    Hernigou, Philippe; Pariat, Jacques

    2017-07-01

    The first techniques of operative fracture with plates were developed in the 19th century. In fact, at the beginning these methods consisted of an open reduction of the fracture usually followed by a very unstable fixation. As a consequence, the fracture had to be opened with a real risk of (sometimes lethal) infection, and due to unstable fixation, protection with a cast was often necessary. During the period between World Wars I and II, plates for fracture fixation developed with great variety. It became increasingly recognised that, because a fracture of a long bone normally heals with minimal resorption at the bone ends, this may result in slight shortening and collapse, so a very rigid plate might prevent such collapse. However, as a consequence, delayed healing was observed unless the patient was lucky enough to have the plate break. One way of dealing with this was to use a slotted plate in which the screws could move axially, but the really important advance was recognition of the role of compression. After the first description of compression by Danis with a "coapteur", Bagby and Müller with the AO improved the technique of compression. The classic dynamic compression plates from the 1970s were the key to a very rigid fixation, leading to primary bone healing. Nevertheless, the use of strong plates resulted in delayed union and the osteoporosis, cancellous bone, comminution, and/or pathological bone resulted in some failures due to insufficient stability. Finally, new devices represented by locking plates increased the stability, contributing to the principles of a more biological osteosynthesis while giving enough stability to allow immediate full weight bearing in some patients.

  1. Tympanic plate fractures in temporal bone trauma: prevalence and associated injuries.

    Science.gov (United States)

    Wood, C P; Hunt, C H; Bergen, D C; Carlson, M L; Diehn, F E; Schwartz, K M; McKenzie, G A; Morreale, R F; Lane, J I

    2014-01-01

    The prevalence of tympanic plate fractures, which are associated with an increased risk of external auditory canal stenosis following temporal bone trauma, is unknown. A review of posttraumatic high-resolution CT temporal bone examinations was performed to determine the prevalence of tympanic plate fractures and to identify any associated temporal bone injuries. A retrospective review was performed to evaluate patients with head trauma who underwent emergent high-resolution CT examinations of the temporal bone from July 2006 to March 2012. Fractures were identified and assessed for orientation; involvement of the tympanic plate, scutum, bony labyrinth, facial nerve canal, and temporomandibular joint; and ossicular chain disruption. Thirty-nine patients (41.3 ± 17.2 years of age) had a total of 46 temporal bone fractures (7 bilateral). Tympanic plate fractures were identified in 27 (58.7%) of these 46 fractures. Ossicular disruption occurred in 17 (37.0%). Fractures involving the scutum occurred in 25 (54.4%). None of the 46 fractured temporal bones had a mandibular condyle dislocation or fracture. Of the 27 cases of tympanic plate fractures, 14 (51.8%) had ossicular disruption (P = .016) and 18 (66.6%) had a fracture of the scutum (P = .044). Temporomandibular joint gas was seen in 15 (33%) but was not statistically associated with tympanic plate fracture (P = .21). Tympanic plate fractures are commonly seen on high-resolution CT performed for evaluation of temporal bone trauma. It is important to recognize these fractures to avoid the preventable complication of external auditory canal stenosis and the potential for conductive hearing loss due to a fracture involving the scutum or ossicular chain.

  2. A lateral approach for screw repair in lag fashion of spiral third metacarpal and metatarsal medial condylar fractures in horses.

    Science.gov (United States)

    Smith, Lewis C R; Greet, Timothy R C; Bathe, Andrew P

    2009-08-01

    To describe a lateral approach for screw fixation in lag fashion of simple spiral medial condylar fractures of the third metacarpus/metatarsus (MC3/MT3). Case series. Thoroughbred racehorses (n=9). Nondisplaced medial MC3/MT3 condylar fractures (3 thoracic, 6 pelvic limbs), with mean length 126 mm (range, 91-151 mm) were repaired by internal fixation, under general anesthesia, using multiple 4.5 mm cortical screws inserted in lag fashion from the lateral aspect of the limb, using radiographic or fluoroscopic guidance. Horses were recovered from anesthesia in half-limb casts; 7 unassisted and 2 using a rope-recovery system. Horses had 2 months box rest, 1 month in-hand walking, and follow-up radiographic examination at 3 months. Horses recovered uneventfully from anesthesia. Five horses raced; 1 returned to training, was persistently lame, and was retired to stud; 2 were retired directly to stud; and 1 horse was lost to follow-up. MC3/MT3 medial condylar fractures were successfully repaired by screws inserted n lag fashion form the lateral aspect. Use of a lateral approach to medial condylar MC3/MT3 fractures allows screw insertion perpendicular to the fracture plane without interference with palmar/plantar soft tissue structures or from the splint bones. Although repair was performed under general anesthesia, the technique should be adaptable to application in standing horses.

  3. Salter-Harris type II metacarpal and metatarsal fracture in three foals. Treatment by minimally-invasive lag screw osteosynthesis combined with external coaptation.

    Science.gov (United States)

    Klopfenstein Bregger, Micaël D; Fürst, Anton E; Kircher, Patrick R; Kluge, Katharina; Kummer, Martin

    2016-05-18

    To describe minimally-invasive lag screw osteosynthesis combined with external coaptation for the treatment of Salter-Harris type II third metacarpal and third metatarsal bone fractures. Three foals aged two weeks to four months with a Salter-Harris type II third metacarpal or third metatarsal fracture. Surgery was carried out under general anaesthesia in lateral recumbency. After fracture reduction, the metaphyseal fragment was stabilized with two cortical screws placed in lag fashion under fluoroscopic control. A cast was applied for at least two weeks. All foals had a good outcome with complete fracture healing and return to complete soundness without any angular limb deformity. All foals had moderate transient digital hyperextension after cast removal. Internal fixation of Salter-Harris type II third metacarpal or third metatarsal fractures with two cortical screws in lag fashion, combined with external coaptation provided good stabilization and preserved the longitudinal growth potential of the injured physis.

  4. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: A series of 10 cases and surgical guidelines

    Directory of Open Access Journals (Sweden)

    Samir Joshi

    2015-01-01

    Full Text Available Aim: To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Method: Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. Results: All cases showed satisfactory bone healing without any growth disturbance. Conclusion: Open reduction and rigid internal fixation (ORIF with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  5. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: a series of 10 cases and surgical guidelines.

    Science.gov (United States)

    Joshi, Samir; Kshirsagar, Rajesh; Mishra, Akshay; Shah, Rahul

    2015-01-01

    To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. All cases showed satisfactory bone healing without any growth disturbance. Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plates and 4 mm screws is a reliable and safe method in treatment of displaced paediatric mandibular fractures.

  6. CT-guided percutaneous screw fixation plus cementoplasty in the treatment of painful bone metastases with fractures or a high risk of pathological fracture

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio; Ballicu, Nicola; Fele, Rosa Maria; Sotgia, Barbara; Melis, Luca [Oncological Hospital ' ' A. Businco' ' , Regional Referral Center for Oncologic Diseases, Division of Interventional Radiology, Department of Oncological Radiology, Cagliari (Italy); Fancellu, Alessandro [University of Sassari, Department of Clinical and Experimental Medicine, Sassari (Italy)

    2017-04-15

    To evaluate the feasibility and effectiveness of computed tomography (CT)-guided percutaneous screw fixation plus cementoplasty (PSFPC), for either treatment of painful metastatic fractures or prevention of pathological fractures, in patients who are not candidates for surgical stabilization. Twenty-seven patients with 34 metastatic bone lesions underwent CT-guided PSFPC. Bone metastases were located in the vertebral column, femur, and pelvis. The primary end point was the evaluation of feasibility and complications of the procedure, in addition to the length of hospital stay. Pain severity was estimated before treatment and 1 and 6 months after the procedure using the visual analog scale (VAS). Functional outcome was assessed by improved patient walking ability. All sessions were completed and well tolerated. There were no complications related to either incorrect positioning of the screws during bone fixation or leakage of cement. All patients were able to walk within 6 h after the procedure and the average length of hospital stay was 2 days. The mean VAS score decreased from 7.1 (range, 4-9) before treatment to 1.6 (range, 0-6), 1 month after treatment, and to 1.4 (range 0-6) 6 months after treatment. Neither loosening of the screws nor additional bone fractures occurred during a median follow-up of 6 months. Our results suggest that PSFPC might be a safe and effective procedure that allows the stabilization of the fracture and the prevention of pathological fractures with significant pain relief and good recovery of walking ability, although further studies are required to confirm this preliminary experience. (orig.)

  7. Surgical plate fixation of multiple rib fractures: a case report.

    Science.gov (United States)

    Mitev, Konstantin; Neziri, Dashurie; Stoicovski, Emil; Mitrev, Zan

    2018-05-29

    The healthcare system in developing countries is limited; particularly, medical specialties such as emergency and trauma medicine are underdeveloped. Consequently, trauma injuries sustained in traffic accidents result in chronic morbidity more often than similar cases in developed countries. Multiple rib fractures induce significant patient morbidity. Current international guidelines recommend a multidisciplinary, surgery-based treatment approach to achieve optimal clinical benefit. We admitted a 41-year-old Albanian man to our emergency department following a pedestrian-vehicle accident 5 days earlier. He presented with severe upper thoracic pain, chest deformity, dyspnea, tachycardia, subcutaneous emphysema, and hematoma. Chest radiography pointed to hypoventilated lung fields and a minor pleural effusion. Computed tomographic scans indicated displaced fractures of right lateral ribs 5 -11, hyperdensity regions from bone fragments, and pulmonary contusion. The treatment consisted of surgical fixation of ribs 7-10 using titanium reconstruction plates and cortical locking screws. The patient's clinical condition rapidly improved postoperatively. Follow-up at 6 weeks confirmed a full return to preoperative daily activities and a high quality of life. In this case report, we present a novel and promising development in the field of trauma medicine in the Republic of Macedonia. Trauma injuries can be treated via advanced multidisciplinary medical care according to international standards, allowing optimal health recovery.

  8. Double Threaded Screw Fixation for Bilateral Stress Fracture of the Medial Malleolus

    Directory of Open Access Journals (Sweden)

    Ryo Kanto

    2014-01-01

    Full Text Available An 18-year-old college basketball player presented with continued ankle pain. A radiographic examination showed bilateral medial malleolus stress fractures. Considering the prolonged history and refractory nature of this injury, surgery was adopted as a treatment option. At surgery, the fracture site was percutaneously fixed using two cannulated double threaded screws. Surgery for each side was sequentially performed two months apart. Prompt bony healing was attained after surgery, and the patient could return to his previous sports level six months after the first surgery without subsequent recurrence.

  9. EVALUATION OF RESULTS IN FRACTURES OF BOTH BONES FOREARM TREATED WITH DYNAMIC COMPRESSION PLATING

    Directory of Open Access Journals (Sweden)

    Sindhuja G

    2017-06-01

    incisions for radius and ulna and preservation of the natural curves of radius will lessen the rate of complications. Rigid fixation of fractures after perfect anatomical reduction with 3.5 mm DCP and screws allows early mobilisation, prevents soft tissue contracture, muscular tethering and improves vascularity. A minimum of 6 cortices have to be fixed in each fracture fragment and the nearest screw to the fracture line should be at least 1 cm away. It minimises vascular damage to the plated bone segment.

  10. Tricortical cervical inter-body screw fixation.

    Directory of Open Access Journals (Sweden)

    Goel A

    1997-01-01

    Full Text Available A new tricortical method of screw implantation for anterior cervical interbody plate fixation is described. The screws are placed obliquely such that they engage the anterior cortex of the body and traverse through the cortices adjoining the disc space. By this method the screws not only hold the plate firmly with a tricortical purchase, but by virtue of their course stabilize the two adjoining vertebral bodies by themselves. Sixteen patients were treated by this method. In three of these cases only tricortical screws without the metal plate were used for fixation. The advantages of the technique are discussed.

  11. Biomechanical Comparison of 3 Inferiorly Directed Versus 3 Superiorly Directed Locking Screws on Stability in a 3-Part Proximal Humerus Fracture Model.

    Science.gov (United States)

    Donohue, David M; Santoni, Brandon G; Stoops, T Kyle; Tanner, Gregory; Diaz, Miguel A; Mighell, Mark

    2018-06-01

    To quantify the stability of 3 points of inferiorly directed versus 3 points of superiorly directed locking screw fixation compared with the full contingent of 6 points of locked screw fixation in the treatment of a 3-part proximal humerus fracture. A standardized 3-part fracture was created in 10 matched pairs (experimental groups) and 10 nonmatched humeri (control group). Osteosynthesis was performed using 3 locking screws in the superior hemisphere of the humeral head (suspension), 3 locking screws in the inferior hemisphere (buttress), or the full complement of 6 locking screws (control). Specimens were tested in varus cantilever bending (7.5 Nm) to 10,000 cycles or failure. Construct survival (%) and the cycles to failure were compared. Seven of 10 controls survived the 10,000-cycle runout (70%: 8193 average cycles to failure). No experimental constructs survived the 10,000-cycle runout. Suspension and buttress screw groups failed an average of 331 and 516 cycles, respectively (P = 1.00). The average number of cycles to failure and the number of humeri surviving the 10,000-cycle runout were greater in the control group than in the experimental groups (P ≤ 0.006). Data support the use of a full contingent of 6 points of locking screw fixation over 3 superior or 3 inferior points of fixation in the treatment of a 3-part proximal humerus fracture with a locking construct. No biomechanical advantage to the 3 buttress or 3 suspension screws used in isolation was observed.

  12. Impact of double-tiered subchondral support procedure with a polyaxial locking plate on the stability of distal radius fractures using fresh cadaveric forearms: Biomechanical and radiographic analyses.

    Science.gov (United States)

    Tsutsui, Sadaaki; Kawasaki, Keikichi; Yamakoshi, Ken-Ichi; Uchiyama, Eiichi; Aoki, Mitsuhiro; Inagaki, Katsunori

    2016-09-01

    The present study compared the changes in biomechanical and radiographic properties under cyclic axial loadings between the 'double-tiered subchondral support' (DSS) group (wherein two rows of screws were used) and the 'non-DSS' (NDSS) group (wherein only one row of distal screws was used) using cadaveric forearm models of radius fractures fixed with a polyaxial locking plate. Fifteen fresh cadaveric forearms were surgically operated to generate an Arbeitsgemeinschaft für Osteosynthesefragen (AO) type 23-C2 fracture model with the fixation of polyaxial volar locking plates. The model specimens were randomized into two groups: DSS (n = 7) and NDSS (n = 8). Both the groups received 4 locking screws in the most distal row, as is usually applied, whereas the DSS group received 2 additional screws in the second row inserted at an inclination of about 15° to support the dorsal aspect of the dorsal subchondral bone. Cyclic axial compression test was performed (3000 cycles; 0-250 N; 60 mm/min) to measure absolute rigidity and displacement, after 1, 1000, 2000 and 3000 cycles, and values were normalized relative to cycle 1. These absolute and normalized values were compared between those two groups. Radiographic images were taken before and after the cyclic loading to measure changes in volar tilt (ΔVT) and radial inclination (ΔRI). The DSS group maintained significantly higher rigidity and lower displacement values than the NDSS group during the entire loading period. Radiographic analysis indicated that the ΔVT values of the DSS group were lower than those of the NDSS group. In contrast, the fixation design did not influence the impact of loading on the ΔRI values. Biomechanical and radiographic analyses demonstrated that two rows of distal locking screws in the DSS procedure conferred higher stability than one row of distal locking screws. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  13. The use of small (2.7 mm) screws for arthroscopically guided repair of carpal chip fractures.

    Science.gov (United States)

    Wright, I M; Smith, M R W

    2011-05-01

    Removal of large chip fractures of the carpal bones and the osteochondral deficits that result, have been associated with a worse prognosis than removal of small fragments in similar locations. Reducing the articular defects by repair of large osteochondral fragments may have advantages over removal. Horses with osteochondral chip fractures that were of sufficient size and infrastructure to be repaired with small (2.7 mm diameter) AO/ASIF cortex screws were identified and repair effected by arthroscopically guided internal fixation. Thirty-three horses underwent surgery to repair 35 fractures of the dorsodistal radial carpal bone (n = 25), the dorsal margin of the radial facet of the third carpal bone (n = 9) and the intermediate facet of the distal radius (n = 1). There were no surgical complications and fractures healed satisfactorily in 26 of 28 horses and 23 horses returned to racing performance. Arthroscopically guided repair of carpal chip fractures with small diameter cortex screws is technically feasible and experiences with 33 cases suggest that this may have advantages over fragment removal in managing such cases. Surgeons treating horses with large chip fractures of the carpal bones should consider arthroscopically guided internal fixation as an alternative to removal. © 2010 EVJ Ltd.

  14. Biomechanical evaluation of a new MatrixMandible plating system on cadaver mandibles.

    Science.gov (United States)

    Gateno, Jaime; Cookston, Christopher; Hsu, Sam Sheng-Pin; Stal, Drew N; Durrani, Salim K; Gold, Jonathan; Ismaily, Sabir; Alexander, Jerry W; Noble, Philip C; Xia, James J

    2013-11-01

    Current mandibular plating systems contain a wide range of plates and screws needed for the treatment of mandibular reconstruction and mandibular fractures. The authors' hypothesis was that a single diameter screw could be used in all applications in a plating system. Therefore, the purpose of this study was to test if the 2.0-mm locking screws could replace the 2.4-mm screws to stabilize a 2.5-mm-thick reconstruction plate in the treatment of mandibular discontinuity. Thirty-six fresh human cadaveric mandibles were used: 18 were plated using 2.0-mm locking screws (experimental) and the other 18 were plated using 2.4-mm locking screws (control). Each group was further divided into 3 subgroups based on the site of loading application: the ipsilateral (right) second premolar region, the central incisal region, and the contralateral (left) first molar region. The same ipsilateral (right) mandibular angular discontinuity was created by the same surgeon. The mandible was mounted on a material testing machine. The micromotions between the 2 segments, permanent and elastic displacements, were recorded after incremental ramping loads. The magnitude of screw back-out and the separation between plate and bone were recorded using a laser scanner (resolution, 0.12 mm) before and after the loading applications. The data were processed. Descriptive analyses and a general linear model for repeated measures analysis of variance were performed. There was no statistically significant difference in permanent displacement (mean, 1.16 and 0.82 mm, respectively) between the 2.0-mm and 2.4-mm screw groups. There also was no statistically significant difference in elastic displacement between the 2 groups (mean, 1.48 and 1.21 mm, respectively). Finally, there were no statistically significant differences in screw back-out or separation between plate and bone between the 2 groups. All means for screw back-out and separation between screw and bone for each group were judged within the

  15. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    Science.gov (United States)

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  16. Dilemma in pediatric mandible fractures: resorbable or metallic plates?

    Science.gov (United States)

    Taylan Filinte, Gaye; Akan, İsmail Mithat; Ayçiçek Çardak, Gülçin Nujen; Özkaya Mutlu, Özay; Aköz, Tayfun

    2015-12-01

    The aim of this study was to compare the efficiency of resorbable and metallic plates in open reduction and internal fixation of mandible fractures in children. Thirty-one patients (mean age, 8.05 years; range 20 months-14 years) were operated on various fractures of the mandible (26 [60.4%] symphysis- parasymphysis, 12 [27.9%] condylar-subcondylar fractures, 5 [11.6%] angulus and ramus fractures). Twelve patients were treated with resorbable plates and 19 patients with metallic plates. Mean follow-up time was 41 months (11-74 months) in the metallic hardware group and was 22 months (8-35 months) in the resorbable plate group. Both groups were investigated for primary bone healing, complications, number of operations, and mandibular growth. The results were discussed below. Both groups demonstrated primary bone healing. Minor complications were similar in both groups. The metallic group involved secondary operations for plate removal. Mandibular growth was satisfactory in both groups. Resorbable plates cost more than the metallic ones; however, when the secondary operations are included in the total cost, resorbable plates were favourable. As mandibular growth and complication parameters are similar in both groups, resorbable plates are favored due to avoidance of potential odontogenic injury, elimination of long-term foreign body retention and provision of adequate stability for rapid bone healing. However, learning curve and concerns for decreased stability against heavy forces of mastication accompanied with the resorbable plates when compared to the metallic ones should be kept in mind.

  17. Fixation of femoral capital physeal fractures with 7.0 mm cannulated screws in five bulls

    International Nuclear Information System (INIS)

    Wilson, D.G.; Crawford, W.H.; Stone, W.C.; Frampton, J.W.

    1991-01-01

    Salter-Harris type I fractures of the femoral capital physis were repaired in five Holstein bulls with three 7.0 mm cannulated screws placed in lag fashion. Radiographically at months 7 to 10, the fractures were healed and there was periarticular bone production on the femoral necks and the dorsal acetabular rims. Four bulls had normal gaits, and one bull had muscle atrophy and barely detectable lameness

  18. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    Science.gov (United States)

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; Pshaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  19. Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, Julien, E-mail: juliengarnon@gmail.com; Koch, Guillaume, E-mail: Guillaume.koch@gmail.com [University Hospital of Strasbourg, Department of Interventional Radiology (France); Ramamurthy, Nitin, E-mail: Nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Caudrelier, Jean, E-mail: caudjean@yahoo.fr [University Hospital of Strasbourg, Department of Interventional Radiology (France); Rao, Pramod, E-mail: pramodrao@me.com [University of Strasbourg, ICube (France); Tsoumakidou, Georgia, E-mail: Georgia.tsoumakidou@chru-strasbourg.fr; Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Gangi, Afshin, E-mail: Afshin.gangi@chru-strasbourg.fr [University Hospital of Strasbourg, Department of Interventional Radiology (France)

    2016-09-15

    ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.

  20. Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases

    International Nuclear Information System (INIS)

    Garnon, Julien; Koch, Guillaume; Ramamurthy, Nitin; Caudrelier, Jean; Rao, Pramod; Tsoumakidou, Georgia; Cazzato, Roberto Luigi; Gangi, Afshin

    2016-01-01

    ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.

  1. Finite element analysis of the three different posterior malleolus fixation strategies in relation to different fracture sizes.

    Science.gov (United States)

    Anwar, Adeel; Lv, Decheng; Zhao, Zhi; Zhang, Zhen; Lu, Ming; Nazir, Muhammad Umar; Qasim, Wasim

    2017-04-01

    Appropriate fixation method for the posterior malleolar fractures (PMF) according to the fracture size is still not clear. Aim of this study was to evaluate the outcomes of the different fixation methods used for fixation of PMF by finite element analysis (FEA) and to compare the effect of fixation constructs on the size of the fracture computationally. Three dimensional model of the tibia was reconstructed from computed tomography (CT) images. PMF of 30%, 40% and 50% fragment sizes were simulated through computational processing. Two antero-posterior (AP) lag screws, two postero-anterior (PA) lag screws and posterior buttress plate were analysed for three different fracture volumes. The simulated loads of 350N and 700N were applied to the proximal tibial end. Models were fixed distally in all degrees of freedom. In single limb standing condition, the posterior plate group produced the lowest relative displacement (RD) among all the groups (0.01, 0.03 and 0.06mm). Further nodal analysis of the highest RD fracture group showed a higher mean displacement of 4.77mm and 4.23mm in AP and PA lag screws model (p=0.000). The amounts of stress subjected to these implants, 134.36MPa and 140.75MPa were also significantly lower (p=0.000). There was a negative correlation (p=0.021) between implant stress and the displacement which signifies a less stable fixation using AP and PA lag screws. Progressively increasing fracture size demands more stable fixation construct because RD increases significantly. Posterior buttress plate produces superior stability and lowest RD in PMF models irrespective of the fragment size. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Fabrication of mandible fracture plate by indirect additive manufacturing

    Science.gov (United States)

    Aizat, M.; Khan, S. F.

    2017-10-01

    Bone fracture is a serious skeletal injury due to accidents and fragility of the bones at a certain age. In order to accelerate fracture healing process, fracture bone plate is use to hold the fracture segment for more stability. The purpose of this study is to fabricate mandibular fracture plate by using indirect additive manufacturing methods in order to reduce time taken during bending and shaping the fracture fixation plate that conform to the anatomy of the fractured bone site. The design and analysis of the plates are performed using CATIA and ANSYS software. The 3D-CAD data were sent to an additive manufacturing machine (fused filament fabricated) to generate master pattern using PLA and the mould were fabricated using Plaster of Paris. A melt ZAMAK 3 was poured directly into the moulds, and left it until completely harden. 3point bending test was performed on the prototype plate using universal testing machine. Stress-strain curve shows the graph exhibited a linear relationship of stress-strain up to a strain value of 0.001. Specimens give a maximum yielding stress and then break before the conventional deflection. Since the maximum flexural stress and the breaking stress are far apart with a plateau stating at strain value of 0.003mm/mm in most specimens, the specimen’s failure types are considered plastic failure mode. The average thickness and width are 1.65mm and 2.18mm respectively. The flexural modulus and flexural strength are 189.5GPa and 518.1MPa, respectively.

  3. A Passive and Wireless Sensor for Bone Plate Strain Monitoring.

    Science.gov (United States)

    Tan, Yisong; Hu, Jiale; Ren, Limin; Zhu, Jianhua; Yang, Jiaqi; Liu, Di

    2017-11-16

    This paper reports on a sensor for monitoring bone plate strain in real time. The detected bone plate strain could be used for judging the healing state of fractures in patients. The sensor consists of a magnetoelastic material, which can be wirelessly connected and passively embedded. In order to verify the effectiveness of the sensor, a tibia-bone plate-screw (TBS) model was established using the finite element analysis method. A variation of the bone plate strain was obtained via this model. A goat hindquarter tibia was selected as the bone fracture model in the experiment. The tibia was fixed on a high precision load platform and an external force was applied. Bone plate strain variation during the bone fracture healing process was acquired with sensing coils. Simulation results indicated that bone plate strain decreases as the bone gradually heals, which is consistent with the finite element analysis results. This validated the soundness of the sensor reported here. This sensor has wireless connections, no in vivo battery requirement, and long-term embedding. These results can be used not only for clinical practices of bone fracture healing, but also for bone fracture treatment and rehabilitation equipment design.

  4. Close Intramedullary Interlocking Nailing Versus Locking Compression Plating In the Treatment of Closed Fracture Shaft of the Tibia.

    Science.gov (United States)

    Kundu, I K; Datta, N K; Chowdhury, A Z; Das, K P; Tarik, M M; Faisal, M A

    2016-07-01

    Fracture of tibial shaft is the commonest site of long bone fractures due to its superficial location involving young or middle-age people. Proper management is an important issue regarding the future effective movements. In this study patients were grouped in closed Intra medullary interlocking nailing and locking compression plating. Post-operative follow up at 2 weeks, 6 weeks, 12 weeks and 3 months thereafter up to 6 months were done. Each of the patients was evaluated clinically and radiologically by tucker criteria of Tuker et al. Patients were assessed for pain on full weight bearing and kneeling, shortening and range of motion of knee and ankle joints. Radiological assessment for union of fracture, alignment of fracture and angulations and position of nail and screws and infection were observed during follow up. A total number of 32 patients were selected but only 27 patients were available for follow up for a period of 6 months. They were grouped into Group A, consisting of 15 patients who took the treatment in the form of closed intramedullary interlocking nailing and Group B, consisting of 12 patients those underwent ORIF with locking compression plating. In both of the groups Motor Vehicle Accident was the main mechanism of trauma. Fracture involving the middle 3rd of the tibia is common in both the groups. During post-operative follow up, four patients in Group A complained anterior knee pain, one patient in Group B had superficial infection, most of the patients had no restriction of movement in the ankle and knee joints and a single patient in Group B showed 1.5cm shortening of the lower limb. Period of hospital stay and fracture union time were less in Group A, which was statistically significant. Both groups showed excellent result with minimum complications. So this study permits to conclude that close IM interlocking nailing and open reduction and internal fixation by locking compression plating is equally effective for the management of close

  5. Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

    Science.gov (United States)

    Königshausen, M; Kübler, L; Godry, H; Citak, M; Schildhauer, T A; Seybold, D

    2012-02-01

    The surgical treatment of displaced proximal humeral fractures (ORIF) is a perpetual challenge to the surgeon. For this reason, the principle of polyaxiality was developed to provide an improved primary stability of the fracture through better anchorage of the screws, especially in osteoporotic bone. The aim of this study was to present clinical results with the polyaxial locking plate in the operative treatment of proximal humerus fractures in order to determine whether the technique of polyaxiality leads to better functional outcome and lower complication rates in comparison to monoaxial plates in the literature. Seventy-three patients with displaced proximal humeral fractures were treated surgically with the polyaxial locking Suture Plate™ (Arthrex(®)) between 03/2007 and 06/2009. Fifty-two of the patients (mean age, 69.9 ± 12.1) were included in a radiographical and clinical examination using the Constant score (CS) and the Disabilities of the Arm, Shoulder and Hand score (DASH). The follow-up examinations were on average 13.9 ± 4.5 months (10-27 months) after surgical treatment. The mean CS of the patients was 66.0 ± 13.7 points, the age- and gender-related CS was 90.9% ± 20.0% and the mean DASH score was 23.8 ± 19.8 points for the injured side. The patients with a nearly anatomical reduction of their fracture (n = 13) reached a significantly higher CS (75.1 ± 8.5; p = 0.004) and DASH-score (13.6 ± 11.6; p = 0.043) and none of these patients had a complication. The complications were identified in 12 (23.1%) cases, 5 of which involved loss of reduction. All of these 5 cases were lacking of initial medial column support and 4 of which were type C2.3 AO-Classification. The data show that the combination of angular stability with the possibility of variable polyaxial screw direction is a good concept for reduction and fixation of displaced proximal humeral fractures, but anatomical reduction and medial support remain important preconditions for a good

  6. Is the lag screw sliding effective in the intramedullary nailing in A1 and A2 AO-OTA intertrochanteric fractures? A prospective study of Sliding and None-sliding lag screw in Gamma-III nail

    Directory of Open Access Journals (Sweden)

    Zhu Yi

    2012-09-01

    Full Text Available Abstract Object To compare the Sliding with Non-sliding lag screw of a gamma nail in the treatment of A1 and A2 AO-OTA intertrochanteric fractures. Materials and methods 80 patients were prospectively collected. In each group, AO/OTA 31-A were classified into group A. AO/OTA 31-A2.1 was classified as group B. We classified the A2.2 and A2.3 as group C. According to the set-screw locking formation of Gamma-III, the cases were randomly allocated to Sliding subgroup and Non-sliding subgroup in A, B and C groups. Follow-ups were performed 1, 3, 6 and 12 months postoperatively. Results In the Sliding group, the bone healing rate 3, 6, 12 months postoperatively reached 85.00%, 97.50%, 100% in group A, B and C. Meanwhile, in Non-sliding group, postoperatively, bone healing rate were 90.00%, 95.00% and 97.50% in group A, B and C, respectively. Both differences were not significant. Lower limb discrepancy between Sliding and Non-sliding pattern was significantly different in group C which represent fracture types of AO/OTA 31-A2.2 and A2.3 (0.573 ± 0.019 mm in Non-sliding group, 0.955 mm ± 0.024 mm in Sliding group, P Conclusions As a result, we can conclude that the sliding distance is minimal in Gamma nails and it is related to the comminuted extent of the intertrochanteric area in A1 and A2 AO-OTA intertrochanteric fractures. For treating these kinds of fractures, the sliding of the lag screw of an Gamma nail does not improve any clinical results and in certain cases, such as highly comminuted A1 and A2 fractures, can therefore even benefit from a locked lag screw by tightening the set-screw.

  7. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2013-10-01

    Full Text Available Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. Keywords: Hip dislocation; acetabular fractures; intertrochanteric fracture; operative treatment.

  8. Plate Fixation With Autogenous Calcaneal Dowel Grafting Proximal Fourth and Fifth Metatarsal Fractures: Technique and Case Series.

    Science.gov (United States)

    Seidenstricker, Chad L; Blahous, Edward G; Bouché, Richard T; Saxena, Amol

    Metaphyseal and proximal diaphyseal fractures of the lateral column metatarsals can have problems with healing. In particular, those involving the fifth metatarsal have been associated with a high nonunion rate with nonoperative treatment. Although intramedullary screw fixation results in a high union rate, delayed healing and complications can occur. We describe an innovative technique to treat both acute and chronic injuries involving the metatarsal base from the metaphysis to the proximal diaphyseal bone of the fourth and fifth metatarsals. The surgical technique involves evacuation of sclerotic bone at the fracture site, packing the fracture site with compact cancellous bone, and plate fixation. In our preliminary results, 4 patients displayed 100% radiographic union at a mean of 4.75 (range 4 to 6) weeks with no incidence of refracture, at a mean follow-up point of 3.5 (range 1 to 5) years. The early results with our small series suggest that this technique is a useful treatment choice for metaphyseal and proximal diaphyseal fractures of the fourth and fifth metatarsals. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Conservative treatment of a mandibular condyle fracture: Comparing intermaxillary fixation with screws or arch bar. A randomised clinical trial.

    Science.gov (United States)

    van den Bergh, B; Blankestijn, J; van der Ploeg, T; Tuinzing, D B; Forouzanfar, T

    2015-06-01

    A mandibular condyle fracture can be treated conservatively by intermaxillary fixation (IMF) or by open reposition and internal fixation (ORIF). Many IMF-modalities can be chosen, including IMF-screws (IMFS). This prospective multi-centre randomised clinical trial compared the use of IMFS with the use of arch bars in the treatment of mandibular condyle fractures. The study population consisted of 50 patients (mean age: 31.8 years). Twenty-four (48%) patients were allocated in the IMFS group. Twenty-six (52%) patients were assigned to the arch bars group. In total 188 IMF-screws were used (5-12 screws per patient, mean 7.83 screws per patient). All pain scores were lower in the IMFS group. Three patients developed a malocclusion (IFMS-group: one patient, arch bars-group: two patients). Mean surgical time was significantly shorter in the IMFS group (59 vs. 126 min; pfractured on insertion (0.53%), one (0.53%) screw was inserted into a root. Six (3.2%) screws loosened spontaneously in four patients. Mucosal disturbances were seen in 22 patients, equally divided over both groups. Considering the advantages and the disadvantages of IMFS, and observing the results of this study, the authors conclude that IMFS provide a superior method for IMF. IMFS are safer for the patients and surgeons. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Sacroiliac Screw Fixation

    NARCIS (Netherlands)

    E.W. van den Bosch

    2003-01-01

    textabstractThe aim of this thesis is to evaluate three major aspects of the use of sacroiliac screws in patients with unstable pelvic ring fractures: the optimal technique for sacroiliac screw fixation, the reliability of peroperative fluoroscopy and the late results. We focused on the questions

  11. Post wall fixation by lag screw only in associated both column fractures with posterior wall involvement.

    Science.gov (United States)

    Wang, Hu; Utku, Kandemir; Zhuang, Yan; Zhang, Kun; Fu, Ya-Hui; Wei, Xing; Wang, Peng-Fei; Cong, Yu-Xuan; Lei, Jin-Lai; Zhang, Bin-Fei

    2017-07-01

    To evaluate the quality of reduction, clinical outcomes and complications of associated both column acetabular fractures with posterior wall involvement that are treated through single ilioinguinal approach and fixation of posterior wall by lag screws only. We conducted a retrospective review involving ninety-nine consecutive patients with associated both column fractures of acetabulum treated through single ilioinguinal approach. Patients were divided into two groups. The first group consisted of 35 patients presented with both column fractures with posterior wall involvement that fixation performed with lag screws. This group was compared to a second group of 64 patients with both column fractures without posterior wall involvement. The quality of reduction was assessed using criteria described by Matta. The size of posterior wall fragment was measured. Functional outcome was evaluated using Modified Postel Merle D'Aubigne score. Radiographs at the latest follow up were analyzed for arthritis (Kellgren-Lawrence classification), and femoral head avascular necrosis (Ficat/Arlet classification). The study showed no significant differences in all preoperative variables (P>0.05). While intraoperative blood loss and operative time in group 1 were increased compared to group 2, the difference was not statistically significant (P>0.05). The height, relative depth and peripheral length of posterior wall respectively were 27.8±2.5mm (range: 24-35mm), 71.5±5.4% (range: 65-88%), 23.0±2.3mm (range: 17-28mm). The mean posterior wall fracture displacement is 5.0±3.2mm (range: 0-11mm). There was no difference regarding the quality of reduction between the two groups (P>0.05). The excellent to good clinical outcome was around 71.4% in the group 1 versus 73.4% in the group 2 at the final follow-up, this difference was not statistically significant (P>0.05). There was no difference in rate of complications between the two groups (P>0.05). Lag screws fixation of posterior wall

  12. [Treatment of periprosthetic and peri-implant fractures : modern plate osteosynthesis procedures].

    Science.gov (United States)

    Raschke, M J; Stange, R; Kösters, C

    2012-11-01

    Periprosthetic fractures are increasing not only due to the demographic development with high life expectancy, the increase in osteoporosis and increased prosthesis implantation but also due to increased activity of the elderly population. The therapeutic algorithms are manifold but general valid rules for severe fractures are not available. The most commonly occurring periprosthetic fractures are proximal and distal femoral fractures but in the clinical routine fractures of the tibial head, ankle, shoulder, elbow and on the borders to other implants (peri-implant fractures) and complex interprosthetic fractures are being seen increasingly more. It is to be expected that in the mid-term further options, such as cement augmentation of cannulated polyaxial locking screws will extend the portfolio of implants for treatment of periprosthetic fractures. The aim of this review article is to present the new procedures for osteosynthesis of periprosthetic fractures.

  13. Lubrication of dislocation glide in MgO by hydrous defects

    Science.gov (United States)

    Skelton, Richard; Walker, Andrew M.

    2018-02-01

    Water-related defects, principally in the form of protonated cation vacancies, are potentially able to weaken minerals under high-stress or low-temperature conditions by reducing the Peierls stress required to initiate dislocation glide. In this study, we use the Peierls-Nabarro (PN) model to determine the effect of protonated Mg vacancies on the 1/2{110} and 1/2{100} slip systems in MgO. This PN model is parameterized using generalized stacking fault energies calculated using plane-wave density functional theory, with and without protonated Mg vacancies present at the glide plane. It found that these defects increase dislocation core widths and reduce the Peierls stress over the entire pressure range 0-125 GPa. Furthermore, 1/2{110} slip is found to be more sensitive to the presence of protonated vacancies which increases in the pressure at which {100} becomes the easy glide plane for 1/2 screw dislocations. These results demonstrate, for a simple mineral system, that water-related defects can alter the deformation behavior of minerals in the glide-creep regime by reducing the stress required to move dislocations by glide. (Mg, Fe)O is the most anisotropic mineral in the Earth's lower mantle, so the differential sensitivity of the major slip systems in MgO to hydrous defects has potential implications for the interpretation of the seismic anisotropy in this region.

  14. Proximal femoral fractures: Principles of management and review of literature

    Science.gov (United States)

    Mittal, Ravi; Banerjee, Sumit

    2012-01-01

    Purpose The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. Methods: A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Results and conclusions: Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems. PMID:25983451

  15. [Surgical treatment for talar neck fracture of Hawkins III, IV type with compression hollow screws combined with external fixator].

    Science.gov (United States)

    Wang, Xian-Xun; Wan, Chang-Tao; Yu, Li

    2017-05-25

    To investigate the clinical effects of compression hollow screws combined with external fixator in treating talar neck fracture of Hawkins III, IV type. From March 2010 to August 2014, 15 patients with talar neck fractures of Hawkins III, IV type were treated by open reduction and compression hollow screws fixation complicated with external fixator fixation. Including 9 males and 6 females, aged from 17 to 65 years old with an average of 37.5 years old. There were 9 cases of Hawkins III and 6 cases of Hawkins IV type. Postoperative radiographs and CT of ankle were used to evaluate the fracture healing and talar necrosis. The function of ankle and foot were evaluated by American Society of Ankle and Foot Surgery(AOFAS). All the patients were followed up for 8 to 55 months with an average of 23.5 months and all fractures got bone healing from 13 to 38 weeks with an average of (17.99±6.81) weeks. Traumatic arthritis occurred in 7 cases and talar necrosis in 6 cases (2 cases of type III and 4 cases of type IV) after operation. The average AOFAS score was 61.80±18.75, including excellent in 4 cases, good in 2 cases, fair in 4 cases and poor in 5 cases. Talar neck fracture with Hawkins III, IV type has large possibility to develop avascular necrosis. Hollow compression screw combined with external fixation may late weight-bearing for ankle and can sufficiently guarantee bone healing time, and achieve good results for the treatment of talar neck fracture.

  16. Difference between radiological and functional outcome with deltoid-splitting approach versus deltopectoral approach for the management of proximal humeral fractures with philos plate

    Directory of Open Access Journals (Sweden)

    Shah Waliullah

    2013-01-01

    Full Text Available Background: Proximal humeral fractures are one of the common fractures of upper extremity. Good results by various studies have been reported for proximal humeral locking plate (PHILOS fixation in proximal humeral fractures. We want to evaluate whether it is only the implant which has given good results or different surgical approach utilized for fixation of plate also affects result. Materials and Methods: A total of 57 patients with proximal humeral fractures were divided in two groups, in Group A, patient′s classical deltopectoral approach utilized, while in Group B deltoid-splitting approach was used. All patients were managed by PHILOS plate fixation. Cases were followed up clinically as well as radiologically at 4-6 weeks after operation and thereafter at 10-12 weeks and then at 6 monthly for long-term complications. Functional outcomes of patient were accessed in terms Constant Scoring System, while radiological evaluation was done by taking x-rays to access quality of reduction and union of fracture. Results: All patients were followed for a minimum of 18 months. In Group B, reduction of tuberosities was better in 3 part and 4 part fractures. Mean Constant score in Group A at the end of 3 months was 56, while in Group B it was 62 and statistically significant (P = 0.02. At the end of 18 months, mean Constant score in Group A was 79, while in Group B it was 81 and statistically insignificant (P = 0.72. One patient in Group B showed axillary nerve paresis in postoperative period and recovered at the end of 3 months. Conclusion: We recommend that deltoid-splitting approach can be used in 3 part and 4 part complex proximal humeral fractures and in posterior fracture dislocation shoulder, which are difficult to approach with deltopectoral approach; however, care should be taken while inserting calcar screw in PHILOS plate fixation to avoid iatrogenic axillary nerve injury.

  17. Comparison of cannulated screw and dynamic hip screw for the treatment of femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Mehmet Gem

    2015-09-01

    Full Text Available Objective: We aimed to compare the results of surgeries for intracapsular femoral neck fractures with cannulated screws(CS and dynamic hip screw(DHS, due to lack of evidence which implant for internal fixation of femoral neck fractures is better . Methods: In our clinic between September 2005 and November 2009, 38 patients were operated with intracapsular transcervical fracture of collum femoris between17 to 65 years of age. Eighteen were operated with DHS(47.4% and 20 were operated with CS fixation(52.6%. Results: 16 patients (42.1% were female and 22 (57.9% were male and the mean age was 37.13 (17-65 years. The mean duration of follow-up was 18.05 (2-57 months. 26 patients were operated in 1st -3rd day (68.4%, 9 patients were operated in 4 to 7 day (23.7%, 3 patients were operated in after 7th day (7.9%. In the DHS group, 9 (50% patients had avascular necrosis (AVN, 6 (33.3% patients had implant failure, 3 (16.7% patients had delayed union, 5 (27.8% patients had nonunion, 1 (5.6% patient had infection, and 1 (5.6% patient had myositis ossificans. According to the criteria of Salvati Wilson hip joint assessment, in the DHS group 8 patients (44.4% were very good, 5 patients (27.8% were good, 5 patients (27.8% were moderate. Salvati score was evaluated as average of 28 points (16-40. İn the CS group, 8 (40% patients had AVN, 1 (5% had delayed union, 3 (15% of the cases had nonunion and 1 (5% patients infection was detected. According to the criteria of the Salvati-Wilson, in the CS group13 (65% of them are very good, 5 (25% were good, 2 (10% were assessed as moderate. Salvati score was evaluated as average of 33 points (18-40. In the CS group none of the patients had implant failure, in the DHS group 6 patients had implant failure (33.3% (p<0,05. Conclusion: Except for the high rate of implant failure detection in the DHS group method, no significant difference between complications and functional results between two groups. J Clin Exp Invest

  18. Fracture Analyses of Cracked Delta Eye Plates in Ship Towing

    Science.gov (United States)

    Huang, Xiangbing; Huang, Xingling; Sun, Jizheng

    2018-01-01

    Based on fracture mechanics, a safety analysis approach is proposed for cracked delta eye plates in ship towing. The static analysis model is presented when the delta eye plate is in service, and the fracture criterion is introduced on basis of stress intensity factor, which is estimated with domain integral method. Subsequently, three-dimensional finite element analyses are carried out to obtain the effective stress intensity factors, and a case is studied to demonstrate the reasonability of the approach. The results show that the classical strength theory is not applicable to evaluate the cracked plate while fracture mechanics can solve the problem very well, and the load level, which a delta eye plate can carry on, decreases evidently when it is damaged.

  19. Dynamics of screw dislocations : a generalised minimising-movements scheme approach

    NARCIS (Netherlands)

    Bonaschi, G.A.; Meurs, van P.J.P.; Morandotti, M.

    2015-01-01

    The gradient flow structure of the model introduced in [CG99] for the dynamics of screw dislocations is investigated by means of a generalised minimising-movements scheme approach. The assumption of a finite number of available glide directions, together with the "maximal dissipation criterion" that

  20. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    Directory of Open Access Journals (Sweden)

    Zacharia Facaros

    2010-10-01

    Full Text Available The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This technique may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss.

  1. DLS 5.0--the biomechanical effects of dynamic locking screws.

    Directory of Open Access Journals (Sweden)

    Stefan Döbele

    Full Text Available INTRODUCTION: Indirect reduction of dia-/metaphyseal fractures with minimally invasive implant application bridges the fracture zone in order to protect the soft-tissue and blood supply. The goal of this fixation strategy is to allow stable motion at the fracture site to achieve indirect bone healing with callus formation. However, concerns have arisen that the high axial stiffness and eccentric position of locked plating constructs may suppress interfragmentary motion and callus formation, particularly under the plate. The reason for this is an asymmetric fracture movement. The biological need for sufficient callus formation and secondary bone healing is three-dimensional micro movement in the fracture zone. The DLS was designed to allow for increased fracture site motion. The purpose of the current study was to determine the biomechanical effect of the DLS_5.0. METHODS: Twelve surrogate bone models were used for analyzing the characteristics of the DLS_5.0. The axial stiffness and the interfragmentary motion of locked plating constructs with DLS were compared to conventional constructs with Locking Head Screws (LS_5.0. A quasi-static axial load of 0 to 2.5 kN was applied. Relative motion was measured. RESULTS: The dynamic system showed a biphasic axial stiffness distribution and provided a significant reduction of the initial axial stiffness of 74.4%. Additionally, the interfragmentary motion at the near cortex increased significantly from 0.033 mm to 0.210 mm (at 200N. CONCLUSIONS: The DLS may ultimately be an improvement over the angular stable plate osteosynthesis. The advantages of the angular stability are not only preserved but even supplemented by a dynamic element which leads to homogenous fracture movement and to a potentially uniform callus distribution.

  2. Minimally invasive percutaneous plate fixation of distal tibia fractures.

    LENUS (Irish Health Repository)

    Bahari, Syah

    2007-10-01

    We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one case of deep infection. Mean SF36 score was 85 and mean AOFAS score was 90 at a mean of 19 months follow-up. We report satisfactory outcomes with the use of the AO distal tibia locking plate in treatment of unstable distal tibial fractures. Eighty-nine percent of the patients felt that they were back to their pre injury status and 95% back to their previous employment.

  3. Fractures of the bilateral distal radius and scaphoid: a case report

    Directory of Open Access Journals (Sweden)

    Ozkan Korhan

    2008-03-01

    Full Text Available Abstract Introduction Bilateral fractures of the distal radius and scaphoid are extremely rare injuries. Case presentation A patient with bilateral comminuted, displaced distal fractures of the radius and bilateral fractures of the scaphoid was treated via internal fixation of the scaphoid fractures with Herbert screws and internal fixation of the distal radius fractures with locked volar plating. Conclusion Rigid internal fixation of distal radius and scaphoid fractures is mandatory to start early active rehabilitation of the wrist without the need for wrist immobilization with a plaster or external skeletal fixation.

  4. Treatment of zygomatic complex fractures in an urban Saudi Arabian population: A 10-year retrospective survey

    Directory of Open Access Journals (Sweden)

    Ali-Alsuliman Dawood

    2018-01-01

    Full Text Available Background: Zygomatic complex fractures (ZMCF are treated by various closed and open reduction procedures. The common goal, however, is to achieve three-dimensional stability of the fractured zygoma. Patients and Methods: All cases diagnosed with ZMCF were included in this study over a 10-year-period starting from December 2002 to December 2012 at Riyadh Dental Centre, King Saud Medical City-Riyadh, Saudi Arabia. Patient's gender, age, etiology, and type of treatment modality of the zygomatic bone fracture were retrieved and recorded. Data were stored and statistically analyzed using SPSS (ver. 16.0; SPSS Inc., Chicago, IL, USA. Results were presented as simple frequencies and percentages. Results: A total of 306 patients were diagnosed with ZMCF during the study period. There were 271 (88.6% males and 35 (11.4% females with a male-to-female ratio of 7.7:1. Age range of 21–30 years had the highest number of maxillofacial fracture. A total of 62 (20.3% cases were treated by closed reduction while 235 (76.8% cases were treated by open reduction and internal fixation using titanium miniplate (2.0 mm and screws. Combination of treatment modalities was utilized in only 9 (2.9% cases. Complications observed during the review period were palpable plate and screws in 26 (8.4% patients. These palpable plates and screws, however, did not necessitate plate and screw removal from any of these patients. Conclusion: Most of the ZMCF were treated by open reduction and rigid internal fixation. Advances in imaging, surgical technique, and materials for fixation have allowed for improved functional and esthetic outcomes.

  5. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    Science.gov (United States)

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  6. A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws.

    Science.gov (United States)

    Zhang, Y L; Zhang, W; Zhang, C Q

    2017-04-01

    The Pauwels angle has been used widely, however an accurate evaluation of this angle is difficult because of deformity of the affected lower extremity. Therefore we designed a new measurement of the orientation of femoral neck fracture and applied this in a retrospective study to assess: (1) its reproducibility, (2) its advantages compared with the Pauwels angle, (3) its relationship with the short-term prognosis treated with three cannulated compression screws. This new measurement is reproducible and has some reference meaning for the treatment of femoral neck fractures. Two hundred and twenty-eight patients with femoral neck fractures treated with three cannulated compression screws were retrospectively analyzed. The VN angle, which was the angle between the fracture line and the vertical of the neck axis, and the Pauwels angle were measured respectively. The method of ICC was performed to assess the reproducibility of the two angles, and the absolute value of difference in pre-operative and post-operative radiographs was used to evaluate the uniformity of the two angles. These fractures were divided into four groups according to VN angle (VN50°) were respectively 0%, 1.46% (95% CI: 1.42-1.50) and 36.24% (95% CI: 34.93-37.54). The VN angle has a good inter-rater reproducibility, a higher reliability than the Pauwels angle and is closely related to the short-term prognosis of femoral neck fractures treated with cannulated compression screws. Level IV, retrospective diagnostic study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Determination of activation parameters for the core transformation of the screw dislocation in silicon

    International Nuclear Information System (INIS)

    Guénolé, J; Godet, J; Pizzagalli, L

    2010-01-01

    The non-dissociated screw dislocation in a model covalent material like silicon is known to exist in three possible stable core configurations. We performed calculations combining the nudged elastic band technique and a semi-empirical description in order to determine mechanisms and activation parameters for transforming one core into another. Our results showed that a glide core is necessarily reconstructed, since the energy barrier for reconstruction is easily overcome by thermal activation. Conversely, a transformation between a shuffle and a glide core appears unlikely at low temperature, which raises questions about the existence of the double-period glide configuration

  8. Epidemiological analysis of mandibular fractures treated in Sao Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Kelly Marinho

    2015-10-01

    Conclusion: The treatment of mandibular fractures should be aimed at restoring the occlusion and mastication function, with surgery being the most indicated treatment, using reduction and internal fixation with the use of a plates and screws system based on the experience of the authors. Knowledge of surgical techniques and methods of reduction and fixation of fractures, and periodic monitoring allow these patients to receive the appropriate treatment.

  9. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two- and three-part fractures.

    Science.gov (United States)

    Schliemann, Benedikt; Seifert, Robert; Theisen, Christina; Gehweiler, Dominic; Wähnert, Dirk; Schulze, Martin; Raschke, Michael J; Weimann, Andre

    2017-01-01

    The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.

  10. Fractures of the growing mandible.

    Science.gov (United States)

    Kushner, George M; Tiwana, Paul S

    2009-03-01

    Oral and maxillofacial surgeons must constantly weigh the risks of surgical intervention for pediatric mandible fractures against the wonderful healing capacity of children. The majority of pediatric mandibular fractures can be managed with closed techniques using short periods of maxillomandibular fixation or training elastics alone. Generally, the use of plate- and screw-type internal fixation is reserved for difficult fractures. This article details general and special considerations for this surgery including: craniofacial growth & development, surgical anatomy, epidemiology evaluation, various fractures, the role rigid internal fixation and the Risdon cable in pediatric maxillofacial trauma. It concludes with suggestions concerning long-term follow-up care in light of the mobility, insurance obstacles, and family dynamics facing the patient population.

  11. Adhesion improvement of glass-fibre-reinforced polyester composites by gliding arc discharge treatment

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Sørensen, Bent F.; Løgstrup Andersen, Tom

    2013-01-01

    A gliding arc is a plasma that can be operated at atmospheric pressure and applied for plasma surface treatment for adhesion improvement. In the present work, glass-fibre-reinforced polyester plates were treated using an atmospheric pressure gliding arc discharge with an air flow to improve...

  12. Bioabsorbable metal screws in traumatology: A promising innovation

    Directory of Open Access Journals (Sweden)

    Roland Biber

    2017-04-01

    Full Text Available MAGNEZIX® CS (Syntellix AG, Hanover, Germany is a bioabsorbable compression screw made of a magnesium alloy (MgYREZr. Currently there are only two clinical studies reporting on a limited number of elective patients who received this screw in a hallux valgus operation. We applied MAGNEZIX® CS for fixation of distal fibular fracture in a trauma patient who had sustained a bimalleolar fracture type AO 44-B2.3. Clinical course was uneventful, fracture healing occurred within three months. Follow-up X-rays showed a radiolucent area around the implant for some months, yet this radiolucent area had disappeared in the 17-months follow-up X-ray. Keywords: Magnesium, Bioabsorbable, Compression screw, Osteosynthesis, Ankle fracture

  13. [Particular posteromedial and posterolateral approaches for the treatment of tibial head fractures].

    Science.gov (United States)

    Lobenhoffer, P; Gerich, T; Bertram, T; Lattermann, C; Pohlemann, T; Tscheme, H

    1997-12-01

    Tibial plateau fractures with depression of posterior aspects of the proximal tibia cause significant therapeutic problems. Posterior fractures on the medial side are mainly highly instable fracture-dislocations (Moore type I). Posterolateral fractures usually cause massive depression and destruction of the chondral surface. Surgical exposure of these fractures from anterior requires major soft tissue dissection and has a significant complication rate. However, incomplete restoration of the joint surface results in chronic postero-inferior joint subluxation, osteoarthritis and pain. We present new specific approaches for posterior fracture types avoiding large skin incisions, but allowing for atraumatic exposure, reduction and fixation. Posteromedial fracture-dislocations are exposed by a direct posteromedial skin incision and a deep incision between medial collateral ligament and posterior oblique ligament. The posteromedial pillar and the posterior flare of the proximal tibia are visualized. The inferior extent of the joint fragment can be reduced by indirect techniques or direct manipulation of the fragment. Fixation is achieved with subchondral lag screws and an anti-glide plate at the tip of the fragment. Posterolateral fractures are exposed by a transfibular approach: the skin is incised laterally, the peroneal nerve is dissected free. The fibula neck is osteotomized, the tibiofibular syndesmosis is divided and the fibula neck is reflected upwards in one layer with the meniscotibial ligament and the iliotibial tract attachment. Reflexion of the fibula head relaxes the lateral collateral ligament, allows for lateral joint opening and internal rotation of the tibia and thus exposes the posterolateral and posterior aspect of the tibial plateau. Fixation and buttressing on the posterolateral side can be achieved easily with this approach. In closure, the fibula head is fixed back with a lag screw or a tension-band system. These two exposures can be combined in

  14. Metallic artifacts from internal scaphoid fracture fixation screws: comparison between C-arm flat-panel, cone-beam, and multidetector computed tomography.

    Science.gov (United States)

    Finkenstaedt, Tim; Morsbach, Fabian; Calcagni, Maurizio; Vich, Magdalena; Pfirrmann, Christian W A; Alkadhi, Hatem; Runge, Val M; Andreisek, Gustav; Guggenberger, Roman

    2014-08-01

    The aim of this study was to compare image quality and extent of artifacts from scaphoid fracture fixation screws using different computed tomography (CT) modalities and radiation dose protocols. Imaging of 6 cadaveric wrists with artificial scaphoid fractures and different fixation screws was performed in 2 screw positions (45° and 90° orientation in relation to the x/y-axis) using multidetector CT (MDCT) and 2 flat-panel CT modalities, C-arm flat-panel CT (FPCT) and cone-beam CT (CBCT), the latter 2 with low and standard radiation dose protocols. Mean cartilage attenuation and metal artifact-induced absolute Hounsfield unit changes (= artifact extent) were measured. Two independent radiologists evaluated different image quality criteria using a 5-point Likert-scale. Interreader agreements (Cohen κ) were calculated. Mean absolute Hounsfield unit changes and quality ratings were compared using Friedman and Wilcoxon signed-rank tests. Artifact extent was significantly smaller for MDCT and standard-dose FPCT compared with CBCT low- and standard-dose acquisitions (all P 0.05). Both MDCT and FPCT standard-dose protocols showed equal ratings for screw bone interface, fracture line, and trabecular bone evaluation (P = 0.06, 0.2, and 0.2, respectively) and performed significantly better than FPCT low- and CBCT low- and standard-dose acquisitions (all P < 0.05). Good interreader agreement was found for image quality comparisons (Cohen κ = 0.76-0.78). Both MDCT and FPCT standard-dose acquisition showed comparatively less metal-induced artifacts and better overall image quality compared with FPCT low-dose and both CBCT acquisitions. Flat-panel CT may provide sufficient image quality to serve as a versatile CT alternative for postoperative imaging of internally fixated wrist fractures.

  15. IMF-screws or arch bars as conservative treatment for mandibular condyle fractures: quality of life aspects

    NARCIS (Netherlands)

    van den Bergh, B.; de Mol van Otterloo, J.J.; van der Ploeg, T.; Tuinzing, D.B.; Forouzanfar, T.

    2015-01-01

    Objective Arch bars as treatment for a fractured mandibular condyle are inconvenient to patients and lead to lowered quality of life (QOL). To overcome these inconveniences, IMF-screws (IMFS) to facilitate intermaxillary fixation during surgery have been developed. The purpose of the present study

  16. IMF-screws or arch bars as conservative treatment for mandibular condyle fractures: Quality of life aspects

    NARCIS (Netherlands)

    van den Bergh, B.; van Otterloo, J.J.D.M.; van der Ploeg, T.; Tuinzing, D.B.; Forouzanfar, T.

    2015-01-01

    Objective Arch bars as treatment for a fractured mandibular condyle are inconvenient to patients and lead to lowered quality of life (QOL). To overcome these inconveniences, IMF-screws (IMFS) to facilitate intermaxillary fixation during surgery have been developed. The purpose of the present study

  17. The prognostic value of tip-to-apex distance (TAD index) in intertrochanteric fractures fixed by dynamic hip screw.

    Science.gov (United States)

    Sedighi, Ali; Sales, Jafar Ganjpour; Alavi, Sahar

    2012-11-02

    Intertrochanteric fractures (ITFs) are the most common type of fractures requiring surgical intervention. They also have the highest surgical mortality among orthopedic operations. Among the many different techniques used for fixation of this type of fracture, use of the Dynamic Hip Screw (DHS) has gained wide acceptance. This current study was designed to assess positive predictive value of tip-to-apex distance (TAD) index in the prognosis of patients treated with DHS. The study was designed according to a descriptive-analytic protocol, made up of 100 cases of ITFs caused by falling, treated in the Shohada Orthopedic Center, Tabriz, Iran. All patients underwent lateral and antero-posterior hip X-ray to measure TAD index. The cohort was followed for three months after DHS placement. Of a total of 100 cases (53 male, 47 female) with a mean age of 76.7 years (range 29-100 years), 43% had grade 4, 29% grade 3, 21% grade 5, 5% grade 2 and 2% grade 6 osteoporosis. The screw position was postero-inferior in 57%, central in 40% and superior in 3% of patients. Minimum and maximum TAD index were 20 and 28 mm, respectively. Mean TAD was 23.5 mm. There were no post-operative complications in 84% of cases. Screw failure was the most common complication in the remaining 16% of patients. The study shows a statistically significant correlation between TAD index and cut-off rate in patients with intertrochanteric fractures of femoral bone treated by DHS. This validates the use of TAD index in determining the prognosis of patients treated by DHS.

  18. Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation

    DEFF Research Database (Denmark)

    Palm, Henrik; Jacobsen, Steffen; Sonne-Holm, Stig

    2007-01-01

    BACKGROUND: Reoperations after intertrochanteric fractures are often necessitated by fracture displacement following mobilization of the patient. The biomechanical complexity of the fracture, the position of the implant, and the patient's characteristics are known to influence postoperative outcome....... We investigated the importance of an intact lateral femoral wall as a factor in postoperative fracture displacement after fixation with a sliding compression hip screw. METHODS: Two hundred and fourteen consecutive patients with an intertrochanteric fracture were treated with a 135 degrees sliding...... compression hip screw with a four-hole side-plate between 2002 and 2004. The fractures were classified on preoperative radiographs according to the AO/OTA classification system. The status of the greater and lesser trochanters, the integrity of the lateral femoral wall, and the position of the implant were...

  19. Long-term outcome of pronation-external rotation ankle fractures treated with syndesmotic screws only.

    Science.gov (United States)

    Lambers, Kaj T A; van den Bekerom, Michel P J; Doornberg, Job N; Stufkens, Sjoerd A S; van Dijk, C Niek; Kloen, Peter

    2013-09-04

    There is sparse information in the literature on the outcome of Maisonneuve-type pronation-external rotation ankle fractures treated with syndesmotic screws. The primary aim of this study was to determine the long-term results of such treatment of these fractures as indicated by standardized patient-based and physician-based outcome measures. The secondary aim was to identify predictors of the outcome with use of bivariate and multivariate statistical analysis. Fifty patients with pronation-external rotation (predominantly Maisonneuve) fractures were treated with open reduction and internal fixation of the syndesmosis utilizing only one or two screws. The results were evaluated at a mean of twenty-one years after the fracture utilizing three standardized outcomes instruments: (1) the Foot and Ankle Ability Measure (FAAM), (2) the American Orthopaedic Foot & Ankle Society (AOFAS) ankle-hindfoot scale, and (3) the Center for Epidemiologic Studies-Depression (CES-D) Scale. Osteoarthritis was graded according to the van Dijk and revised Takakura radiographic scoring systems. Bivariate and multivariate analyses were performed to identify predictors of long-term outcome. Forty-four (92%) of forty-eighty patients had good or excellent AOFAS scores, and forty-four (90%) of forty-nine had good or excellent FAAM scores. Arthrodesis for severe osteoarthritis was performed in two patients. Radiographic evidence of osteoarthritis was observed in twenty-four (49%) of forty-nine patients. Multivariate analysis identified pain as the most important independent predictor of long-term ankle function as indicated by the AOFAS and FAAM scores, explaining 91% and 53% of the variation in scores, respectively. Analysis of pain as the dependent variable in bivariate analyses revealed that depression, ankle range of motion, and a subsequent surgery were significantly correlated with higher pain scores. No firm conclusions could be drawn after multivariate analysis of predictors of pain

  20. Locking plates in distal humerus fractures: study of 43 patients

    Directory of Open Access Journals (Sweden)

    Gupta Rakesh Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal hu-merus fractures. Methods: Forty-three consecutive patients with ar-ticular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score. Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years. Clinical and ra-diological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks. The average follow-up was 12 months (10-18 months. Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%. One pa-tient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy. Conclusion: Anatomically preshaped distal humerus locking

  1. Condylar Joint Fusion and Stabilization (by Screws and Plates) in Nontraumatic Atlanto-Occipital Dislocation: Technical Report of 2 Cases.

    Science.gov (United States)

    Chowdhury, Forhad H; Haque, Mohammod Raziul; Alam, Sarwar Murshed; Khaled Chowdhury, S M Noman; Khan, Shamsul Islam; Goel, Atul

    2017-11-01

    Nontraumatic spontaneous atlanto-occipital dislocation (AOD) is rare. In this report, we discuss the technical steps of condylar joint fusion and stabilization (by screws and plates) in nontraumatic AOD. To the best of our knowledge, it is the first report of such techniques. A young girl and a young man with progressive quadriparesis due to nontraumatic spontaneous atlanto-occipital dislocation were managed by microsurgical reduction, fusion, and stabilization of the joint by occipital condylar and C1 lateral mass screw and plate fixation after mobilization of vertebral artery. In both cases, condylar joints fixation and fusion were done successfully. Condylar joint stabilization and fusion may be a good or alternative option for AOD. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.

    Science.gov (United States)

    Jain, R; Podworny, N; Hearn, T; Anderson, G I; Schemitsch, E H

    1997-10-01

    Comparison of the effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture. Randomized, prospective. Orthopaedic research laboratory. Ten large (greater than twenty-five kilogram) adult dogs. A short, midshaft spiral tibial fracture was created, followed by lag screw fixation and neutralization with an eight-hole, 3.5-millimeter, low-contact dynamic compression plate (LCDCP) made of either 316L stainless steel (n = five) or commercially pure titanium (n = five). After surgery, animals were kept with unrestricted weight-bearing in individual stalls for ten weeks. Cortical bone blood flow was assessed by laser Doppler flowmetry using a standard metalshafted probe (Periflux Pf303, Perimed, Jarfalla, Sweden) applied through holes in the custom-made LCDCPs at five sites. Bone blood flow was determined at four times: (a) prefracture, (b) postfracture, (c) postplating, and (d) ten weeks postplating. After the dogs were killed, the implant was removed and both the treated tibia and contralateral tibia were tested for bending stiffness and load to failure. Fracture creation decreased cortical perfusion in both groups at the fracture site (p = 0.02). The application of neither stainless steel nor titanium LCDCPs further decreased cortical bone blood flow after fracture creation. However, at ten weeks postplating, cortical perfusion significantly increased compared with acute postplating levels in the stainless steel (p = 0.003) and titanium (p = 0.001) groups. Cortical bone blood flow ten weeks postplating was not significantly different between the titanium group and the stainless steel group. Biomechanical tests performed on the tibiae with the plates removed did not reveal any differences in bending stiffness nor load required to cause failure between the two groups. Both titanium and stainless steel LCDCPs were equally effective in allowing revascularization, and

  3. Decrease in Hydrogen Embrittlement Susceptibility of 10B21 Screws by Bake Aging

    Directory of Open Access Journals (Sweden)

    Kuan-Jen Chen

    2016-08-01

    Full Text Available The effects of baking on the mechanical properties and fracture characteristics of low-carbon boron (10B21 steel screws were investigated. Fracture torque tests and hydrogen content analysis were performed on baked screws to evaluate hydrogen embrittlement (HE susceptibility. The diffusible hydrogen content within 10B21 steel dominated the fracture behavior of the screws. The fracture torque of 10B21 screws baked for a long duration was affected by released hydrogen. Secondary ion mass spectroscopy (SIMS result showed that hydrogen content decreased with increasing baking duration, and thus the HE susceptibility of 10B21 screws improved. Diffusible hydrogen promoted crack propagation in high-stress region. The HE of 10B21 screws can be prevented by long-duration baking.

  4. Biomechanical testing of a hybrid locking plate fixation of equine sesamoid osteotomies.

    Science.gov (United States)

    Almeida da Silveira, E; Levasseur, A; Lacourt, M; Elce, Y; Petit, Y

    2014-01-01

    To compare the biomechanical properties of a hybrid locking compression plate (LCP) construct with the compression screw technique as a treatment for transverse mid-body proximal sesamoid bone fractures. Ten paired forelimbs from abattoir horses were used. The medial proximal sesamoid bone of each limb was osteotomized transversely and randomly assigned, to either repair with a two-hole 3.5 mm LCP or a 4.5 mm cortical screw placed in lag fashion. Each limb was tested biomechanically by axial loading in single cycle until failure. The point of failure was evaluated from the load-displacement curves. Then a gross evaluation and radiographs were performed to identify the mode of failure. The loads to failure of limbs repaired with the hybrid LCP construct (4968 N ± 2167) and the limbs repaired with the screw technique (3009 N ± 1091) were significantly different (p fracture of the apical fragment of the proximal sesamoid bone. The LCP technique has potential to achieve a better fracture stability and healing when applied to mid-body fractures of the proximal sesamoid bone. Further testing, particularly fatigue resistance is required to corroborate its potential as a treatment option for mid-body fractures of the proximal sesamoid bone.

  5. OUTCOME OF LOCKING PLATES IN DISTAL TIBIA FRACTURES TREATMENT

    OpenAIRE

    Lokesh; Dayanand; Deepak; Hemanth

    2016-01-01

    INTRODUCTION Most of these fractures except intra-articular fractures are treated with interlocking nail. 1,2 These nails are a boon for these fractures. But as the fracture nears to the joint stability the fracture fixation will be compromised due to malreduction and alignment, it leads to increased chances of delayed and nonunion. 3 Locking anatomical plates are evaluated for anatomical and relative stability fixation. Since then most intra and near intra-articul...

  6. Percutaneous pedicle screw for unstable spine fractures in polytraumatized patients: A report of two cases

    Directory of Open Access Journals (Sweden)

    Boon Beng Tan

    2012-01-01

    Full Text Available Unstable spine fractures commonly occur in the setting of a polytraumatized patient. The aim of management is to balance the need for early operative stabilization and prevent additional trauma due to the surgery. Recent published literature has demonstrated the benefits of early stabilization of an unstable spine fracture particularly in patients with higher injury severity score (ISS. We report two cases of polytrauma with unstable spine fractures stabilized with a minimally invasive percutaneous pedicle screw instrumentation system as a form of damage control surgery. The patients had good recovery from the polytrauma injuries. These two cases illustrate the role of minimally invasive stabilization, its limitations and technical pitfalls in the management of unstable spine fractures in the polytrauma setting as a form of damage control surgery.

  7. Clinical study on the application of minimally invasive percutaneous pedicle screw fixation in single segment thoracolumbar fracture without neurological symptoms

    Directory of Open Access Journals (Sweden)

    Jin-ping LIU

    2016-04-01

    Full Text Available Objective To discuss the clinical effects of minimally invasive percutaneous pedicle screw fixation in the treatment of single segment thoracolumbar fracture without neurological symptoms.  Methods From June 2012 to October 2014, 38 neurologically intact patients with thoracolumbar fracture underwent surgeries, including open pedicle screw fixation in 16 cases and percutaneous pedicle screw fixation in 22 cases. The incision length, operation time, intraoperative blood loss, postoperative drainage and postoperative complication were recorded and compared between 2 groups. Thoracolumbar orthophoric, lateral and flexion-extension X-ray was used to measure sagittal Cobb angle and height of injured anterior vertebral body before and after operation. Modified Macnab evaluation was used to assess the curative effects 3 months after operation. Results The success rate of operations in 38 patients was 100%. There were a total of 114 vertebral bodies fused and 228 pedicle screws implanted. Patients in the percutaneous pedicle screw group had smaller incision length [(10.55 ± 1.23 cm vs (18.50 ± 2.50 cm, P = 0.000], less intraoperative blood loss [(32.55 ± 7.22 ml vs (320.50 ± 15.48 ml, P = 0.000], shorter hospital stay [(6.55 ± 1.50 d vs (13.50 ± 2.52 d, P = 0.000], and without postoperative drainage. The follow-up after operation ranged from 3 to 6 months, with the average time of (4.65 ± 1.24 months. Cobb angle was reduced (P = 0.000 and height of injured anterior vertebral body were improved signifcantly (P = 0.000 3 months after surgery in both groups. The total effective rate was 14/16 in open surgery group, and 86.36% (19/22 in percutaneous pedicle screw group, however, the difference between 2 groups was not significant (P = 1.000. Conclusions Minimally invasive percutaneous pedicle screw fixation is a surgical method with less iatrogenic injury, less intraoperative blood loss and quick recovery for patients with thoracolumbar fracture

  8. A computational study on the effect of fracture intrusion distance in three- and four-part trochanteric fractures treated with Gamma nail and sliding hip screw.

    Science.gov (United States)

    Goffin, Jérôme M; Pankaj, Pankaj; Simpson, A Hamish

    2014-01-01

    Using finite element analysis, the behaviors of the Gamma nail and the sliding hip screw (SHS) were compared in an osteoporotic bone model for the fixation of three- and four-part trochanteric fractures (31-A2 in the AO classification, types IV and V in Evans' classification). The size of the medial fragment was varied based on clinical data, and the case of a fractured greater trochanter was also considered. Our results showed that for Evans' type V stabilized with a Gamma nail and for Evans' types IV and V with the SHS, cancellous bone around the lag screw is susceptible to yielding, thus indicating a risk of cut-out. The volume of bone susceptible to yielding increases with an increase in size of the medial fragment. Conversely, Evans' type IV with a Gamma nail was not predicted to cut out. Our findings suggest that future clinical trials investigating fixation of unstable proximal fractures should include the size of the medial fragment and the integrity of the greater trochanter as covariables and be powered to evaluate whether intramedullary devices are superior to SHSs for Evans' type IV fractures and inferior/equivalent for type V. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. In vitro evaluation of allogeneic bone screws for use in internal fixation of transverse fractures created in proximal sesamoid bones obtained from equine cadavers.

    Science.gov (United States)

    Sasaki, Naoki; Takakuwa, Jun; Yamada, Haruo; Mori, Ryuji

    2010-04-01

    To evaluate effectiveness of allogeneic bone screws and pins for internal fixation of midbody transverse fractures of equine proximal sesamoid bones (PSBs) in vitro. 14 forelimbs from cadavers of 3-year-old Thoroughbreds. Allogeneic cortical bone fragments were collected from the limbs of a male Thoroughbred, and cortical bone screws were prepared from the tissue by use of a precision desktop microlathe programmed with the dimensions of a metal cortical bone screw. A midbody transverse osteotomy of each PSB was performed by use of a bone-shaping oscillating saw and repaired via 1 of 3 internal fixation techniques: 1 allogeneic bone screw with 1 allogeneic bone pin (type I; n = 6 PSBs), 2 allogeneic bone screws (type II; 8), or 1 stainless steel cortical bone screw (control repair; 6). Mechanical tension measurements were obtained by use of a commercially available materials testing system. Mean +/- SD tensile strength (TS) was 668.3 +/- 216.6 N for type I repairs, 854.4 +/- 253.2 N for type II repairs, and 1,150.0 +/- 451.7 N for control repairs. Internal fixation of PSB fractures by the use of allogeneic bone screws and bone pins was successful. Although mean TS of control repairs with stainless steel cortical bone screws was greater than the mean TS of type I and type II repairs, the difference between type II and control repairs was not significant. Allogeneic screws may advance healing and result in fewer complications in a clinical setting.

  10. Clinical and radiological results 6 years after treatment of traumatic thoracolumbar burst fractures with pedicle screw instrumentation and balloon assisted endplate reduction

    NARCIS (Netherlands)

    Verlaan, Jorrit Jan; Somers, Inne; Dhert, Wouter J A; Oner, F. Cumhur

    2015-01-01

    Background context  When used to fixate traumatic thoracolumbar burst fractures, pedicle screw constructs may fail in the presence of severe vertebral body comminution as the intervertebral disc can creep through the fractured endplates leading to insufficient anterior column support.

  11. The prognostic value of tip-to-apex distance (TAD index in intertrochanteric fractures fixed by dynamic hip screw

    Directory of Open Access Journals (Sweden)

    Ali Sadighi

    2012-11-01

    Full Text Available Intertrochanteric fractures (ITFs are the most common type of fractures requiring surgical intervention. They also have the highest surgical mortality among orthopedic operations. Among the many different techniques used for fixation of this type of fracture, use of the Dynamic Hip Screw (DHS has gained wide acceptance. This current study was designed to assess positive predictive value of tip-to-apex distance (TAD index in the prognosis of patients treated with DHS. The study was designed according to a descriptive-analytic protocol, made up of 100 cases of ITFs caused by falling, treated in the Shohada Orthopedic Center, Tabriz, Iran. All patients underwent lateral and antero-posterior hip X-ray to measure TAD index. The cohort was followed for three months after DHS placement. Of a total of 100 cases (53 male, 47 female with a mean age of 76.7 years (range 29-100 years, 43% had grade 4, 29% grade 3, 21% grade 5, 5% grade 2 and 2% grade 6 osteoporosis. The screw position was postero-inferior in 57%, central in 40% and superior in 3% of patients. Minimum and maximum TAD index were 20 and 28 mm, respectively. Mean TAD was 23.5 mm. There were no post-operative complications in 84% of cases. Screw failure was the most common complication in the remaining 16% of patients. The study shows a statistically significant correlation between TAD index and cut-off rate in patients with intertrochanteric fractures of femoral bone treated by DHS. This validates the use of TAD index in determining the prognosis of patients treated by DHS.

  12. Does the titanium plate fixation of symphyseal fracture affect mandibular growth?

    Science.gov (United States)

    Bayram, Burak; Yilmaz, Alev Cetinsahin; Ersoz, Esra; Uckan, Sina

    2012-11-01

    The effect of metallic fixation on growth is a major concern in children and is not yet clear. The aim of this study was to evaluate the effect of metallic fixation of mandibular symphyseal fracture on mandibular growth.Eighteen 90-day-old growing white New Zealand rabbits weighing 1.6 to 2.5 kg were included in this study and divided into 2 groups of 9 subjects. In the experimental group, animals underwent mandibular osteotomy, simulating a symphyseal fracture on the midline of mandibular symphysis. The bone segments were fixed with microplates and microscrews (1.6 mm).In the control group, the same surgical incision without performing symphyseal osteotomy was conducted, and 2 screws were inserted on each side of the symphyseal midline.Digital cephalometric and submentovertex radiographs were taken before the operation and at postoperative 6 months for each animal in 2 groups, and cephalometric measurements were performed. The distance between the centers of the head of 2 screws measured at the end of surgery in the control group was compared with measurements at 6 months after surgery. Obtained data were statistically analyzed.There is no statistically significant difference between the 2 groups for growth amount of both sides of the mandible. Difference of ANS-Id (the most anterior points of nasal bone, the most anterior point on the alveolar bone between the lower incisors) and Cd-Id (the uppermost and most distal point of the mandibular condyle, the most anterior point on the alveolar bone between the lower incisors) values of the 2 groups is not statistically significant (P > 0.05).The distance between the 2 screws at the first application significantly increased at the postoperative sixth month (P mandibular symphyseal fracture does not affect the vertical and sagittal mandibular growth in growing rabbits.

  13. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients.

    Science.gov (United States)

    Gupta, Rakesh K; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2010-12-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-mm limited-contact locking compression plate (LC-LCP) was used in 33 fractures, the metaphyseal LCP in 27 fractures and the distal medial tibial LCP in the remaining 20 fractures. Fibula fixation was performed in the majority of comminuted fractures (n = 41) to maintain the second column of the ankle so as to achieve indirect reduction and to prevent collapse of the fracture. There were two cases of delayed wound breakdown in fractures fixed with the 4.5-mm LC-LCP. Five patients required primary bone grafting and three patients required secondary bone grafting. All cases of delayed union (n = 7) and nonunion (n = 3) were observed in cases where plates were used in bridge mode. Minimally invasive plate osteosynthesis (MIPO) with LCP was observed to be a reliable method of stabilisation for these fractures. Peri-operative docking of fracture ends may be a good option in severely impacted fractures with gap. The precontoured distal medial tibial LCP was observed to be a better tolerated implant in comparison to the 4.5-mm LC-LCP or metaphyseal LCP with respect to complications of soft tissues, bone healing and functional outcome, though its contour needs to be modified.

  14. Intramedullary screw fixation with bone autografting to treat proximal fifth metatarsal metaphyseal-diaphyseal fracture in athletes: a case series

    Directory of Open Access Journals (Sweden)

    Tsukada Sachiyuki

    2012-07-01

    Full Text Available Abstract Background Delayed unions or refractures are not rare following surgical treatment for proximal fifth metatarsal metaphyseal-diaphyseal fractures. Intramedullary screw fixation with bone autografting has the potential to resolve the issue. The purpose of this study was to evaluate the result of the procedure. Methods The authors retrospectively reviewed 15 athletes who underwent surgical treatment for proximal fifth metatarsal metaphyseal-diaphyseal fracture. Surgery involved intramedullary cannulated cancellous screw fixation after curettage of the fracture site, followed by bone autografting. Postoperatively, patients remain non weight-bearing in a splint or cast for two weeks and without immobilization for an additional two weeks. Full weight-bearing was allowed six weeks postoperatively. Running was permitted after radiographic bone union, and return-to-play was approved after gradually increasing the intensity. Results All patients returned to their previous level of athletic competition. Mean times to bone union, initiation of running, and return-to-play were 8.4, 8.8, and 12.1 weeks, respectively. Although no delayed unions or refractures was observed, distal diaphyseal stress fractures at the distal tip of the screw occurred in two patients and a thermal necrosis of skin occurred in one patient. Conclusions There were no delayed unions or refractures among patients after carrying out a procedure in which bone grafts were routinely performed, combined with adequate periods of immobilization and non weight-bearing. These findings suggest that this procedure may be useful option for athletes to assuring return to competition level.

  15. Precise placement of lag screws in operative treatment of trochanteric femoral fractures with a new guide system.

    Science.gov (United States)

    Poyanli, Oguz S; Soylemez, Salih; Ozkut, Afsar T; Uygur, Esat; Kemah, Bahattin; Unal, Omer K

    2015-11-01

    We assessed the accuracy of a new guide system that we developed to place lag screws in the proper position with the minimum number of attempts for operative treatment of trochanteric femoral fractures. A total of 55 consecutive trochanteric femoral fractures were treated with a cephalomedullary nail. The first 27 consecutive patients were treated with the standard operation (group A), while the new guide system was used in the last 28 consecutive patients (group B). The numbers of attempts to place K wires and the duration of surgery were noted. Accuracy of lag screw placement was evaluated by measuring the angle of deviation from the central axis of the femoral head. Deviation values ranged from -11̊ to +15̊ for the 27 cases in group A, with a median absolute deviation of 8̊±6̊. That in the 28 cases after the introduction of the new guide system (group B) ranged from -5̊ to +6̊, with a median absolute deviation of 0.5̊±3̊ (Pfractures. The present study indicated that this new guide system and nail facilitate accurate placement of lag screws in the appropriate position with the minimum number of attempts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Directory of Open Access Journals (Sweden)

    Michael Bemelman

    2016-02-01

    Full Text Available More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has becomeavailable suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation.

  17. The Role of Minimally Invasive Plate Osteosynthesis in Rib Fixation: A Review

    Science.gov (United States)

    Bemelman, Michael; van Baal, Mark; Yuan, Jian Zhang; Leenen, Luke

    2016-01-01

    More than a century ago, the first scientific report was published about fracture fixation with plates. During the 1950’s, open reduction and plate fixation for fractures were standardized by the founders of Arbeitsgemeinschaft für osteosynthesefragen/Association for the Study of Internal Fixation. Since the introduction of plate fixation for fractures, several plates and screws have been developed, all with their own characteristics. To accomplice more fracture stability, it was thought the bigger the plate, the better. The counter side was a compromised blood supply of the bone, often resulting in bone necrosis and ultimately delayed or non-union. With the search and development of new materials and techniques for fracture fixation, less invasive procedures have become increasingly popular. This resulted in the minimally invasive plate osteosynthesis (MIPO) technique for fracture fixation. With the MIPO technique, procedures could be performed with smaller incisions and thus with less soft tissue damage and a better preserved blood supply. The last 5 years rib fixation has become increasingly popular, rising evidence has become available suggesting that surgical rib fixation improves outcome of patients with a flail chest or isolated rib fractures. Many surgical approaches for rib fixation have been described in the old literature, however, most of these techniques are obscure nowadays. Currently mostly large incisions with considerable surgical insult are used to stabilize rib fractures. We think that MIPO deserves a place in the surgical treatment of rib fractures. We present the aspects of diagnosis, preoperative planning and operative techniques in regard to MIPO rib fixation. PMID:26889439

  18. Safety screw fixation technique in a case of coracoid base fracture with acromioclavicular dislocation and coracoid base cross-sectional size data from a computed axial tomography study.

    Science.gov (United States)

    Kawasaki, Yoshiteru; Hirano, Tetsuya; Miyatake, Katsutoshi; Fujii, Koji; Takeda, Yoshitsugu

    2014-07-01

    Coracoid base fracture accompanied by acromioclavicular joint dislocation with intact coracoclavicular ligaments is a rare injury. Generally, an open reduction with screw fixation is the first treatment choice, as it protects the important structures around the coracoid process. This report presents a new technique of screw fixation for coracoid base fracture and provides anatomic information on cross-sectional size of the coracoid base obtained by computed tomography (CT). An axial image of the coracoid base was visualized over the neck of the scapula, and a guidewire was inserted into this circle under fluoroscopic guidance. The wire was inserted easily into the neck of scapula across the coracoid base fracture with imaging in only 1 plane. In addition, 25 measurements of the coracoid base were made in 25 subjects on axial CT images. Average length of the long and short axes at the thinnest part of the coracoid base was 13.9 ± 2.0 mm (range 10.6-17.0) and 10.5 ± 2.2 mm (6.6-15.1), respectively. This new screw fixation technique and measurement data on the coracoid base may be beneficial for safety screw fixation of coracoid base fracture.

  19. A Biomechanical Study Comparing Helical Blade with Screw Design for Sliding Hip Fixations of Unstable Intertrochanteric Fractures

    Directory of Open Access Journals (Sweden)

    Qiang Luo

    2013-01-01

    Full Text Available Dynamic hip screw (DHS is a well-established conventional implant for treating intertrochanteric fracture. However, revision surgery sometimes still occurs due to the cutting out of implants. A helical blade instead of threaded screw (DHS blade was designed to improve the fixation power of the osteoporotic intertrochanteric fracture. In this study, the biomechanical properties of DHS blade compared to the conventional DHS were evaluated using an unstable AO/OTA 31-A2 intertrochanteric fracture model. Fifty synthetic proximal femoral bone models with such configuration were fixed with DHS and DHS blade in five different positions: centre-centre (CC, superior-centre (SC, inferior-center (IC, centre-anterior (CA, and centre-posterior (CP. All models had undergone mechanical compression test, and the vertical and rotational displacements were recorded. The results showed that DHS blade had less vertical or rotational displacement than the conventional DHS in CC, CA, and IC positions. The greatest vertical and rotational displacements were found at CP position in both groups. Overall speaking, DHS blade was superior in resisting vertical or rotational displacement in comparison to conventional DHS, and the centre-posterior position had the poorest performance in both groups.

  20. Biomechanical Evaluation of Standard Versus Extended Proximal Fixation Olecranon Plates for Fixation of Olecranon Fractures.

    Science.gov (United States)

    Boden, Allison L; Daly, Charles A; Dalwadi, Poonam P; Boden, Stephanie A; Hutton, William C; Muppavarapu, Raghuveer C; Gottschalk, Michael B

    2018-01-01

    Small olecranon fractures present a significant challenge for fixation, which has resulted in development of plates with proximal extension. Olecranon-specific plates with proximal extensions are widely thought to offer superior fixation of small proximal fragments but have distinct disadvantages: larger dissection, increased hardware prominence, and the increased possibility of impingement. Previous biomechanical studies of olecranon fracture fixation have compared methods of fracture fixation, but to date there have been no studies defining olecranon plate fixation strength for standard versus extended olecranon plates. The purpose of this study is to evaluate the biomechanical utility of the extended plate for treatment of olecranon fractures. Sixteen matched pairs of fresh-frozen human cadaveric elbows were used. Of the 16, 8 matched pairs received a transverse osteotomy including 25% and 8 including 50% of the articular surface on the proximal fragment. One elbow from each pair was randomly assigned to a standard-length plate, and the other elbow in the pair received the extended-length plate, for fixation of the fracture. The ulnae were cyclically loaded and subsequently loaded to failure, with ultimate load, number of cycles, and gap formation recorded. There was no statistically significant difference between the standard and extended fixation plates in simple transverse fractures at either 25% or 50% from the proximal most portion of the articular surface of the olecranon. Standard fixation plates are sufficient for the fixation of small transverse fractures, but caution should be utilized particularly with comminution and nontransverse fracture patterns.

  1. Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures.

    Science.gov (United States)

    Park, Jin Hoon; Kang, Dong-Ho; Lee, Moon Kyu; Yoo, Byoungwoo; Jung, Sang Ku; Hwang, Soo-Hyun; Kim, Jeoung Hee; Oh, Sunkyu; Lee, Eun Jung; Jeon, Sang Ryong; Roh, Sung Woo; Rhim, Seung Chul

    2016-05-01

    A retrospective cohort study. The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. 3.

  2. Posterior coronal plating for tibial fractures: technique and advantages

    Directory of Open Access Journals (Sweden)

    Montu Jain

    2014-04-01

    Full Text Available Objective:Tibial shaft fractures are straightforward to treat but when associated with soft tissue injury particularly at the nail entry/plate insertion site or there is significant comminution proximally or a large butterfly fragment/a second split component in the posterior coronal plane, it is a challenge to the treating surgeon. The aim of the present report is to describe the technique of posterior coronal plating in such a scenario and its advantages. Methods:Between July 2008 and June 2011, 12 patients were pro spectively treated by this approach using 4.5 mm broad dynamic compression plates. Results:The time of bony consolidation and full weight bearing averaged 21.7 weeks (range, 16-26 weeks. Patients were followed up for at least 24 months (range, 24-48 months. At 1 year postoper atively, no loss in reduction or alignment was observed. Mean Hospital for Lower Extremity Measurement Functional Score was 72.8 (range, 64-78. All patients were satisfied with their treatment outcomes. Conclusion:Direct posterior approach and fixation using prone position helps to visualise the fracture fragments and provide rigid fixation. The approach is simple and extensile easily, apart from advantages of less soft tissue and hardware problems compared to standard medial or lateral plating. Key words: Tibial fractures; Bone plates; Orthopedic procedures

  3. Outcome of lag-screw treatment of incomplete fractures of the frontal plane of the radial facet of the third carpal bone in horses.

    Science.gov (United States)

    Rutherford, D J; Bladon, B; Rogers, C W

    2007-04-01

    To describe outcomes for horses diagnosed with incomplete, non-displaced fractures of the frontal plane of the radial facet (INFR) of the third carpal bone (C3) treated by placement of a lag screw across the fracture under arthroscopic guidance. Horses (n=13) diagnosed with INFR and treated between December 1999 and January 2005 using a lag screw placed over the fracture were studied. For each case, five horses matched for sire, age and sex which were not known to have INFR were sought for comparison. Racing performance data were collected from a commercial online database. The racing performance of cases pre- and post-operatively, and of cases and matched horses in the post-operative period was compared. Sixteen INFR were found in the 13 horses. Radiographic evidence of healed fracture lines 2-4 months after surgery was seen in 11/16 (69%) fractures; 11/13 (85%) cases raced again after a median recovery period of 292 (range 149-681) days. Treatment was considered successful in 9/13 (69%) cases, which were still in training or had been retired for reasons other than lameness localised to the middle carpal joint at the end of the study period. Just 6/13 (46%) cases had raced prior to injury. The racing ability pre- and post-operatively of five cases was compared, three (60%) of which performed better post-operatively than they had before. There was no significant difference in racing longevity or ability post-operatively between patients and matched (control) horses. Post-operatively, there was little difference in the racing performance between horses diagnosed with INFR which had a lag screw placed across the fracture line and horses matched for sire, age and sex which were not known to have INFR. Horses which were diagnosed with INFR of C3 and had a lag screw placed across the fracture had a good prognosis for future racing performance.

  4. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    Science.gov (United States)

    2010-01-01

    Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement

  5. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty

    Directory of Open Access Journals (Sweden)

    Denkena Berend

    2010-06-01

    Full Text Available Abstract Background Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. Methods A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. Results The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. Conclusions The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in

  6. A rolling-gliding wear simulator for the investigation of tribological material pairings for application in total knee arthroplasty.

    Science.gov (United States)

    Richter, Berna I; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof

    2010-06-15

    Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only. A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made. The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures. The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants.

  7. Noninvasive method for retrieval of broken dental implant abutment screw

    Directory of Open Access Journals (Sweden)

    Jagadish Reddy Gooty

    2014-01-01

    Full Text Available Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to remove the fractured screw conservatively. This case report describes and demonstrates the technique of using an ultrasonic scaler in the removal of the fracture screw fragment as a noninvasive method without damaging the hex of implants.

  8. Bilateral simultaneous femoral neck and shafts fractures - a case report.

    Science.gov (United States)

    Sadeghifar, Amirreza; Saied, Alireza

    2014-10-01

    Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression plate and both necks were fixed using 6.5 mm cannulated screws. Femur fixation on one side was converted to retrograde nailing because of plate failure. Both neck fractures healed uneventfully. In spite of rarity of concomitant fractures of femoral neck and shaft, this injury must be approached carefully demanding especial attention and careful device selection.

  9. Ununited fracture neck of femur treated with closed reduction and internal fixation with cancellous screw and fibular strut graft

    Directory of Open Access Journals (Sweden)

    Singh Daria

    2006-01-01

    Full Text Available Background: Ununited fracture neck of femur in young adults has been tackled in various ways. Methods: Twenty five patients of ununited fracture neck of femur in age group 21-55 years were treated by closed reduction, cancellous screw fixation and fibular strut graft and followed up for 2-6 years. Time gap between injury and operation was 6 weeks to 58 weeks. Five cases were previously fixed with various fixation devices. Results: Osseous union was achieved in 24 cases with average time of 18.16 weeks. Main complication encountered in follow-up was avascular necrosis of femoral head, others were joint stiffness and shortening. Functional end results were good to excellent in 24 cases. Conclusion: Closed reduction with internal fixation by cancellous screw and fibular strut grafting is easy and useful procedure.

  10. Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator.

    Science.gov (United States)

    Lee, Hyun-Joo; Oh, Chang-Wug; Oh, Jong-Keon; Apivatthakakul, Theerachai; Kim, Joon-Woo; Yoon, Jong-Pil; Lee, Dong-Joo; Jung, Jae-Wook

    2013-05-01

    Minimally invasive plate osteosynthesis (MIPO) has become a popular option for treatment of humeral shaft fractures. However, indirect reduction might risk unpromising results, with mal-alignment/mal-union or nonunion. The purpose of this study was to describe a reproducible MIPO technique that used an external fixator during the procedure as a tool for reduction and maintenance, and to assess the outcomes in patients with humeral shaft fracture. Of 31 consecutive cases of humeral shaft fracture in 30 patients, 29 were included in this study. There were seven simple (type A) and 22 comminuted (type B or C) fractures. After the insertion of one Schanz pin on each proximal and distal humerus, a provisional reduction was achieved by connecting the pins with a monolateral external fixator. The MIPO procedure was then performed over the anterior aspect of the humerus. To evaluate the efficacy of the provisional reduction by external fixator, coronal and sagittal alignments were assessed. We also assessed bony and functional results, including complications, from this technique. There was no case of mal-union >10°, and mean angulation was 1.3° (range 0°-9°) in the coronal plane and 1.2° (range 0°-8°) in the sagittal plane. Twenty-eight of 29 fractures were united, including three delayed unions, with a mean union time of 19.1 weeks (range 12.3-38.4 weeks) and a mean follow-up of 20.8 months (range 13.5-31.0 months). There was one hypertrophic nonunion that healed after fixing with two additional screws. Except one patient with associated injury in the elbow, all patients recovered to pre-injury joint motion. There were two cases of postoperative radial nerve palsy that both recovered completely. We attributed them to manipulation, and not to the Schanz pins or plate fixation. Surgical treatment of humeral shaft fractures with external fixator-assisted reduction and MIPO resulted in excellent reductions and high union rates.

  11. Evaluation of Bone Atrophy After Treatment of Forearm Fracture Using Nonlinear Finite Element Analysis: A Comparative Study of Locking Plates and Conventional Plates.

    Science.gov (United States)

    Matsuura, Yusuke; Rokkaku, Tomoyuki; Suzuki, Takane; Thoreson, Andrew Ryan; An, Kai-Nan; Kuniyoshi, Kazuki

    2017-08-01

    Forearm diaphysis fractures are usually managed by open reduction internal fixation. Recently, locking plates have been used for treatment. In the long-term period after surgery, some patients present with bone atrophy adjacent to the plate. However, a comparison of locking and conventional plates as a cause of atrophy has not been reported. The aim of this study was to investigate long-term bone atrophy associated with use of locking and conventional plates for forearm fracture treatment. In this study we included 15 patients with forearm fracture managed by either locking or conventional plates and with more than 5 years of follow-up. Computed tomographic imaging of both forearms was performed to assess bone thickness and local bone mineral density and to predict bone strength without plate reinforcement based on finite element analysis. Mean patient age at surgery was 48.0 years. Eight patients underwent reduction with fixed locking plates and were followed up for a mean of 79.5 months; the remaining 7 patients were treated with conventional plates and were followed up for a mean of 105.0 months. Compared with the conventional plate group, the locking plate group had the same fractured limb-contralateral limb ratio of cortex bone thickness, but had significantly lower ratios of mineral density adjacent to the plate and adjusted bone strength. This study demonstrated bone atrophy after locking plate fixation for forearm fractures. Treatment plans for forearm fracture should take into consideration the impact of bone atrophy long after plate fixation. Therapeutic IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Metachronous bilateral subtrochanteric fracture of femur in an osteopetrotic bone: A case report with technical note.

    Science.gov (United States)

    Kumar, Dharmendra; Jain, Vijay Kumar; Lal, Hitesh; Arya, Rajinder Kumar; Sinha, Skand

    2012-12-01

    Osteopetrosis is a rare inherited skeletal disorder characterized by increased density. The increased fragility of such dense bone results in a greater incidence of fractures, especially around hip and proximal femur. The surgical treatment of such fractures is difficult due to hard but brittle structure of bone. Herein we report a case of bilateral subtrochanteric fracture in an osteopetrotic patient. It was fixed using a dynamic hip screw with plate.

  13. Isolated olecranon fractures in children affected by osteogenesis imperfecta type I treated with single screw or tension band wiring system: Outcomes and pitfalls in relation to bone mineral density.

    Science.gov (United States)

    Persiani, Pietro; Ranaldi, Filippo M; Graci, Jole; De Cristo, Claudia; Zambrano, Anna; D'Eufemia, Patrizia; Martini, Lorena; Villani, Ciro

    2017-05-01

    The purpose of this study is to compare the results of 2 techniques, tension band wiring (TBW) and fixation with screws, in olecranon fractures in children affected with osteogenesis imperfecta (OI) type I. Between 2010 and 2014, 21 olecranon fractures in 18 children with OI (average age: 12 years old) were treated surgically. Ten patients were treated with the screw fixation and 11 with TBW. A total of 65% of olecranon fractures occurred as a result of a spontaneous avulsion of the olecranon during the contraction of the triceps muscle. The average follow-up was 36 months. Among the children treated with 1 screw, 5 patients needed a surgical revision with TBW due to a mobilization of the screw. In this group, the satisfactory results were 50%. In patients treated with TBW, the satisfactory results were 100% of the cases. The average Z-score, the last one recorded in the patients before the trauma, was -2.53 in patients treated with screw fixation and -2.04 in those treated with TBW. TBW represents the safest surgical treatment for patients suffering from OI type I, as it helps to prevent the rigidity of the elbow through an earlier recovery of the range of motion, and there was no loosening of the implant. In analyzing the average Z-score before any fracture, the fixation with screws has an increased risk of failure in combination with low bone mineral density.

  14. Internal Fixation of Cervical Fractures in Three Horses.

    Science.gov (United States)

    Rossignol, Fabrice; Brandenberger, Olivier; Mespoulhes-Rivière, Céline

    2016-01-01

    To describe the surgical treatment outcome of cervical fractures in 3 horses. Case report. Three client-owned horses with cervical vertebral fractures. Three horses were refered for neck stiffness, pain, and ataxia after a cervical trauma because of a fall. Radiographic examination showed an oblique displaced fracture of the caudal aspect of the body of the second cervical vertebra (C2) in horse 1, an oblique displaced fracture of the caudal aspect of C4 involving the disc between C4 and C5 in horse 2, and a displaced transverse fracture of the body of the axis (C2) extending to the lateral arches and involving the vertebral canal in horse 3. In horse 1, the fracture was reduced and stabilized using a 14-hole narrow DCP plate, applied ventrally, and fixed with cancellous screws. A cervical fusion was performed. In horses 2 and 3, fracture fixation was performed using a 5-hole narrow LCP and 5 mm locking screws. All horses showed improvement and returned to full activity. The fracture healed in all horses. Internal fixation of cervical fracture in these horses was associated with minimal complications, and was associated with healing and a highly functional outcome in all horses. The LCP was preferred and would be recommended for ventral stabilization of selected cases of vertebral fractures. © Copyright 2015 by The American College of Veterinary Surgeons.

  15. Image Guidance to Aid Pedicle Screw Fixation of a Lumbar Fracture-Dislocation Injury in a Toddler.

    Science.gov (United States)

    Houten, John K; Nahkla, Jonathan; Ghandi, Shashank

    2017-09-01

    Pedicle screw fixation of the lumbar spine in children age <2 years is particularly challenging, as successful cannulation of the small pedicle dimensions requires a high level of precision and there are no implants specifically designed for the infant spine. Image-guided navigation is commonly used in adult spinal surgery and may be particularly helpful for the placement of spinal screws in areas where the bony anatomy is small and/or anatomically complex, as in the upper cervical area. A 19-month-old female presented with a fracture-dislocation injury of L1-2. Intraoperative imaging using the O-arm multidimensional imaging system was networked to a workstation, and neuronavigation was used to place pedicle instrumentation with 3.5-mm-diameter polyaxial screws designed for posterior cervical fixation. At a 48-month follow-up, the patient was neurologically intact, demonstrated normal physical development, and was engaging in normal physical activity for her age. Radiographs obtained approximately 4 years postsurgery showed no evidence of loss for fixation. Image-guided placement of pedicle screws may be a useful aid in achieving accurate and safe fixation in the small dimensions of the infant spine. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Treatment of displaced talar neck fractures using delayed procedures of plate fixation through dual approaches.

    Science.gov (United States)

    Xue, Youdi; Zhang, Hui; Pei, Fuxing; Tu, Chongqi; Song, Yueming; Fang, Yue; Liu, Lei

    2014-01-01

    Treatment of talar neck fractures is challenging. Various surgical approaches and fixation methods have been documented. Clinical outcomes are often dissatisfying due to inadequate reduction and fixation with high rates of complications. Obtaining satisfactory clinical outcomes with minimum complications remains a hard task for orthopaedic surgeons. In the period from May 2007 to September 2010, a total of 31 cases with closed displaced talar neck fractures were treated surgically in our department. Injuries were classified according to the Hawkins classification modified by Canale and Kelly. Under general anaesthesia with sufficient muscle relaxation, urgent closed reduction was initiated once the patients were admitted; if the procedure failed, open reduction and provisional stabilisation with Kirschner wires through an anteromedial approach with tibiometatarsal external fixation were performed. When the soft tissue had recovered, definitive fixation was performed with plate and screws through dual approaches. The final follow-up examination included radiological analysis, clinical evaluation and functional outcomes which were carried out according to the Ankle-Hindfoot Scale of the American Orthopaedic Foot and Ankle Society (AOFAS), patient satisfaction and SF-36. Twenty-eight patients were followed up for an average of 25 months (range 18-50 months) after the injury. Only two patients had soft tissue complications, and recovery was satisfactory with conservative treatment. All of the fractures healed anatomically without malunion and nonunion, and the average union time was 14 weeks (range 12-24 weeks). Post-traumatic arthritis developed in ten cases, while six patients suffered from avascular necrosis of the talus. Secondary procedures included three cases of subtalar arthrodesis, one case of ankle arthrodesis and one case of total ankle replacement. The mean AOFAS hindfoot score was 78 (range 65-91). According to the SF-36, the average score of the

  17. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  18. Evaluation of MR issues for the latest standard brands of orthopedic metal implants: plates and screws.

    Science.gov (United States)

    Zou, Yue-Fen; Chu, Bin; Wang, Chuan-Bing; Hu, Zhi-Yi

    2015-03-01

    The study was performed to evaluate magnetic resonance (MR) issues for the latest standard brands of plates and screws used in orthopedic surgery at a 1.5-T MR system, including the safety and metallic artifacts. The plates and screws (made of titanium alloy and stainless steel materials, according to the latest standard brands) were assessed for displacement in degrees, MRI-related heating and artifacts at a 1.5-T MR system. The displacement in degrees of the plates and screws was evaluated on an angel-measurement instrument at the entrance of the MR scanner. The MRI-related heating was assessed on a swine leg fixed with a plate by using a "worst-case" pulse sequence. A rectangular water phantom was designed to evaluate metallic artifacts of a screw on different sequences (T1/T2-weighted FSE, STIR, T2-FSE fat saturation, GRE, DWI) and then artifacts were evaluated on T2-weighted FSE sequence by modifying the scanning parameters including field of view (FOV), echo train length (ETL) and bandwidth to identify the influence of parameters on metallic artifacts. 15 volunteers with internal vertebral fixation (titanium alloy materials) were scanned with MR using axial and sagittal T2-FSE, sagittal T2-FSE fat suppression and STIR with conventional and optimized parameters, respectively. Then all images were graded by two experienced radiologists having the experience of more than 7 years under double-blind studies that is neither of them knew which was conventional parameter group and optimized parameter group. The average deflection angle of titanium alloy and stainless steel implants were 4.3° and 7.7°, respectively, (less than 45°) which indicated that the magnetically induced force was less than the weight of the object. The deflection angle of the titanium alloy implants was less than the stainless steel one (t=9.69, Ptitanium alloy before and after the scan was 0.48°C and stainless steel implants was 0.74°C, respectively, with the background temperature

  19. Non-planar dislocations: 3D models and thermally-activated glide processes

    International Nuclear Information System (INIS)

    Ngan, A.H.W.

    2005-01-01

    In recent years, there has been a renewed interest in studying the cross-slip of screw dislocations in the simple face-centred cubic (FCC) structure. This paper serves to address parallel developments in modelling the cross-slip of screw dislocations in the body-centred cubic (BCC) structure and the ordered L1 2 structure. In the latter two cases, the dislocation cores have non-planar spreading offering high intrinsic Peierls stresses. The flow behaviours of these materials, such as the non-Schmid behaviour and temperature-dependence of flow stress, are largely due to the behaviours of single dislocations. 3D atomistic modelling of the minimum-energy path for the glide processes in these cases is performed with an aim to reconcile with experimentally determined activation energies for slip

  20. EVALUATION OF FUNCTIONAL OUTCOME AFTER OPEN REDUCTION AND INTERNAL FIXATION OF DISTAL FEMUR FRACTURES BY LOCKING COMPRESSION PLATE

    Directory of Open Access Journals (Sweden)

    L. Lokanadha Rao

    2016-09-01

    Full Text Available BACKGROUND In the supra and intercondylar fractures of femur particularly with intra articular extension, patient may develop stiffness of knee, shortening, rotational deformities, internal derangement of knee with instability, varus and valgus deformities which affect patient’s routine lifestyle. If these cases were treated with locking compression plate, the results obtained were successful, superior, timesaving providing early ambulation and least disability improving the functional outcome. MATERIALS AND METHODS This is a prospective interventional study. This study includes 25 supracondylar and intercondylar fractures of femur (both Muller’s Type ‘A’, Type B and Type ‘C’ fractures treated with open reduction and internal fixation by Locking Compression Plate in the Department of Orthopaedics, King George Hospital, Visakhapatnam from September 2013 to September 2015. There are 16 males and 9 females with age ranging from 20 to 80 years with an average of 44.6 years. Average age for males is 28.9 years and average age for females is 25 years. 18 fractures were due to road traffic accidents and 6 cases are due to fall from significant heights, 1 case due to simple fall from standing (osteoporosis. 15 cases were in right femur (60% and 10 cases were in left femur (40%. RESULTS 25 cases were included in the study. There is an increase in the rate of union, decreased time taken for union, increased knee range of motion, decreased time for weight-bearing, postoperative complications and duration for hospital stay. CONCLUSION LCP proved to be a good implant which could take the challenges like poor bone stock, severe comminution both metaphyseal and articular and prove successful. The locking head screws distally have prevented varus collapse, even in cases of osteoporosis. The Condylar LCP can be used in either an open or a minimally invasive manner.

  1. The treatment of subtrochanteric fractures

    Directory of Open Access Journals (Sweden)

    Vučetić Čedomir S.

    2011-01-01

    Full Text Available Subtrochanteric fractures of the femur have a special place because of a significant number of complications following treatment. Powerful loading forces asymmetrically acting to this bone segment, as well as poor vascularization interfere with bone union. There are basically two current approaches in the fixation of subtrochanteric fractures; the first involves a plate with a compression screw and another one is intramedullary (IM nail, with two options: centromedullary (standard interlocking femoral nail and cephalomedullary femoral nail with two modifications, reconstructive and trochanteric. All IM nails may be used by open technique or closed minimal invasive method. IM nailing is favoured in view of a shorter operative time, shorter hospitalisation and complications. Indirect fracture reduction and knowledge of biology of bone fracture may result in full success without any bone graft.

  2. A biomechanical comparison of headless tapered variable pitch compression and ao cortical bone screws for fixation of a simulated midbody transverse fracture of the proximal sesamoid bone in horses.

    Science.gov (United States)

    Eddy, Alison L; Galuppo, Larry D; Stover, Susan M; Taylor, Kenneth T; Jensen, David G

    2004-01-01

    To compare mechanical properties and failure characteristics of 2 methods of fixation for repair of a transverse, midbody fracture of the proximal sesamoid bone (PSB): 4.5-mm AO cortical bone screw (AO) placed in lag fashion and 4/5-mm Acutrak (AT) self-compressing screw. An in vitro biomechanical evaluation of intact forelimb preparations and forelimb preparations with a simulated midbody PSB fracture stabilized by a bone screw. Sixteen paired and 8 unilateral cadaveric equine forelimbs. A midbody transverse osteotomy was created in the medial PSB of bilateral forelimbs of 8 equine cadavers. The osteotomized PSB in 1 forelimb from each cadaver was repaired with an AO screw. The osteotomized PSB in each contralateral limb was repaired with an AT screw. Eight unilateral intact control limbs were also studied. Mechanical properties were determined from axial compression, single cycle to failure, load-deformation curves. Failure characteristics were determined by evaluation of video images and radiographs. No statistically significant differences were found between repair groups. Both AO and AT groups had significantly lower mechanical properties than intact limbs except for stiffness. AO and AT constructs were mechanically comparable when used to stabilize a simulated midbody fracture of the medial PSB. Both constructs were mechanically inferior to intact limbs. Clinical Relevance- The AT screw should be considered for clinical use because of the potential for less soft tissue impingement and superior biocompatibility compared with the stainless-steel AO screw. However, postoperative external coaptation is necessary to augment initial fracture stability for either fixation method, and to maintain a standing metacarpophalangeal joint dorsiflexion angle between 150 degrees and 155 degrees.

  3. Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report.

    Science.gov (United States)

    Ozdemir, Guzelali; Azboy, Ibrahim; Yilmaz, Baris

    2016-01-01

    Periprosthetic fractures around the knee after total knee arthroplasty can be seen in the femur, tibia and patella. The tibial fractures are rare cases. Our case with bilateral tibial stress fracture developed after total knee arthroplasty (TKA) is the first of its kind in the literature. 75-year-old male patient with bilateral knee osteoarthritis had not benefited from conservative treatment methods previously applied. Left TKA was applied. In the second month postoperatively, periprosthetic tibial fracture was identified and osteosynthesis was implemented with locked tibia proximal plate-screw. Bone union in 12 weeks was observed in his follow-ups. After 15 months of his first operation, TKA was applied to the right knee. Postoperatively in the second month, as in the first operation, periprosthetic tibial fracture was detected. Osteosynthesis with locking plate-screw was applied and union in 12 weeks was observed in his follow-up. He was seen mobilized independently and without support in the last control of the case made in the 24th month after the second operation. The number of TKA applications is expected to increase in the future. The incidence of periprosthetic fractures should also be expected to increase in these cases. Periprosthetic tibial fractures after TKA are rarely seen. The treatment of periprosthetic fractures around the knee after TKA can be difficult. In the case of persistent pain in the upper end of the tibia after the surgery, stress fracture should be considered. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. [Conventional plate osteosynthesis].

    Science.gov (United States)

    Klaue, K

    2010-02-01

    Consolidation of bone is an essential clinical problem when treating fractures, fixing osteotomies and fusing joints. In most cases, the means of fixation are plates and screws. The goal is functional postoperative therapy by moving the adjacent joints and thus avoiding the deleterious disadvantages of long-lasting articular immobilization. Pre-operative planning, surgical approach, a good understanding of the precise mechanics of the structure and the biological answer for the various tissues are prerequisites of successful osteosynthesis. The choice of implants and the application of their versatility, as well as their adaptation to individual cases are the key to good results.

  5. Evaluation of MR issues for the latest standard brands of orthopedic metal implants: Plates and screws

    Energy Technology Data Exchange (ETDEWEB)

    Zou, Yue-fen, E-mail: zou_yf@163.com [Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300 Guangzhou Road, Nanjing (China); Chu, Bin, E-mail: 18262636700@163.com [Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300 Guangzhou Road, Nanjing (China); Wang, Chuan-bing, E-mail: wangchuanb_csr@163.com [Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No. 300 Guangzhou Road, Nanjing (China); Hu, Zhi-yi, E-mail: huzhiyi@medmail.com.cn [Department of Spine Surgery, The First Affiliated Hospital of Nanjing Medical University, No. 300 Guangzhou Road, Nanjing (China)

    2015-03-15

    Highlights: •Although previous studies have indicated that most of the orthopedic implants are compatible in MR imaging system especially for titanium alloy, there are still concerns about the safety of patients with stainless steel implants, who were refused to a MR scan in most cases in our country. •In this study, it was verified that both titanium alloy and stainless steel materials (plates and screws) cause a weak force and low MRI-related heating at a 1.5-T or less, which do not pose an additional hazard or risk to patients. In addition, we also had explored the influence of different sequences and parameters on size of metallic artifacts to obtain optimized pulse sequences with appropriate parameters for reducing artifacts, which would be convenient and useful in clinical work. -- Abstract: Purpose: The study was performed to evaluate magnetic resonance (MR) issues for the latest standard brands of plates and screws used in orthopedic surgery at a 1.5-T MR system, including the safety and metallic artifacts. Methods: The plates and screws (made of titanium alloy and stainless steel materials, according to the latest standard brands) were assessed for displacement in degrees, MRI-related heating and artifacts at a 1.5-T MR system. The displacement in degrees of the plates and screws was evaluated on an angel-measurement instrument at the entrance of the MR scanner. The MRI-related heating was assessed on a swine leg fixed with a plate by using a “worst-case” pulse sequence. A rectangular water phantom was designed to evaluate metallic artifacts of a screw on different sequences (T1/T2-weighted FSE, STIR, T2-FSE fat saturation, GRE, DWI) and then artifacts were evaluated on T2-weighted FSE sequence by modifying the scanning parameters including field of view (FOV), echo train length (ETL) and bandwidth to identify the influence of parameters on metallic artifacts. 15 volunteers with internal vertebral fixation (titanium alloy materials) were scanned

  6. Evaluation of MR issues for the latest standard brands of orthopedic metal implants: Plates and screws

    International Nuclear Information System (INIS)

    Zou, Yue-fen; Chu, Bin; Wang, Chuan-bing; Hu, Zhi-yi

    2015-01-01

    Highlights: •Although previous studies have indicated that most of the orthopedic implants are compatible in MR imaging system especially for titanium alloy, there are still concerns about the safety of patients with stainless steel implants, who were refused to a MR scan in most cases in our country. •In this study, it was verified that both titanium alloy and stainless steel materials (plates and screws) cause a weak force and low MRI-related heating at a 1.5-T or less, which do not pose an additional hazard or risk to patients. In addition, we also had explored the influence of different sequences and parameters on size of metallic artifacts to obtain optimized pulse sequences with appropriate parameters for reducing artifacts, which would be convenient and useful in clinical work. -- Abstract: Purpose: The study was performed to evaluate magnetic resonance (MR) issues for the latest standard brands of plates and screws used in orthopedic surgery at a 1.5-T MR system, including the safety and metallic artifacts. Methods: The plates and screws (made of titanium alloy and stainless steel materials, according to the latest standard brands) were assessed for displacement in degrees, MRI-related heating and artifacts at a 1.5-T MR system. The displacement in degrees of the plates and screws was evaluated on an angel-measurement instrument at the entrance of the MR scanner. The MRI-related heating was assessed on a swine leg fixed with a plate by using a “worst-case” pulse sequence. A rectangular water phantom was designed to evaluate metallic artifacts of a screw on different sequences (T1/T2-weighted FSE, STIR, T2-FSE fat saturation, GRE, DWI) and then artifacts were evaluated on T2-weighted FSE sequence by modifying the scanning parameters including field of view (FOV), echo train length (ETL) and bandwidth to identify the influence of parameters on metallic artifacts. 15 volunteers with internal vertebral fixation (titanium alloy materials) were scanned

  7. Plasticity, Fracture and Friction in Steady-State Plate Cutting

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup; Wierzbicki, Tomasz

    1997-01-01

    perpendicular to the direction of motion is derived theoretically in a consistent manner. The perpendicular reaction force is of paramount importance for prediction the structural damage of a ship hull because it governs the vertical ship motion and rock penetration which is strongly coupled with the horizontal...... extension of the presented plate model to include more structural members as for example the stiffeners attached to a ship bottom plating. The fracture process is discussed and the model is formulated partly on the basis of the material fracture toughness. The effect of friction and the reaction force...

  8. Operative treatment of intra-articular calcaneal fractures with calcaneal plates and its complications

    Directory of Open Access Journals (Sweden)

    Rak Vaclav

    2009-01-01

    Full Text Available Background: In a retrospective study we analysed intra-articular calcaneal fracture treatment by comparing results and complications related to fracture stabilization with nonlocking calcaneal plates and locking compression plates. Materials and Methods: We performed 76 osteosynthesis (67 patients of intra-articular calcaneal fractures using the standard extended lateral approach from February 2004 to October 2007. Forty-two operations using nonlocking calcaneal plates (group A were performed during the first three years, and 34 calcaneal fractures were stabilized using locking compression plates (group B in 2007. In the Sanders type IV fractures, reconstruction of the calcaneal shape was attempted. Depending on the type of late complication, we performed subtalar arthroscopy in six cases, arthroscopically assisted subtalar distraction bone block arthrodesis in six cases, and plate removal with lateral-wall decompression in five cases. The patients were evaluated by the AOFAS Ankle-Hindfoot Scale. Results: Wound healing complications were 7/42 (17% in group A and 1/34 (3% in group B. No patient had deep osseous infection or foot rebound compartment syndrome. Preoperative size of Bφhler´s angle correlated with postoperative clinical results in both groups. There were no late complications necessitating corrective procedure or arthroscopy until December 2008 in Group B. All late complications ccurred in Group A. The overall results according to the AOFAS Ankle Hindfoot Scale were good or excellent in 23/42 (55% in group A and in 30/34 (85% in group B. Conclusion: Open reduction and internal fixation of intra-articular calcaneal fractures has become a standard surgical method. Fewer complications and better results related to treatment with locking compression plates confirmed in comparison to nonlocking ones were noted for all Sanders types of intra-articular calcaneal fractures. Age and Sanders type IV fractures are not considered to be the

  9. Fate of the syndesmotic screw--Search for a prudent solution.

    Science.gov (United States)

    Kaftandziev, Igor; Spasov, Marko; Trpeski, Simon; Zafirova-Ivanovska, Beti; Bakota, Bore

    2015-11-01

    Ankle fractures are common injuries. Since the recognition of the importance of syndesmotic injury in ankle fractures, much of the scientific work has been focused on concomitant syndesmotic injury. Despite the invention of novel devices for restoration and maintenance of the congruent syndesmosis following syndesmotic injury, the metallic syndesmotic screw is still considered to be the "gold standard". The aim of this study was to compare the clinical results in patients who retained the syndesmosis screw with those in whom the screw was removed following open reduction and internal fixation of the malleolar fracture associated with syndesmosis disruption. This was a retrospective study of 82 patients. Minimum follow-up was 12 months. Clinical evaluation included American Orthopaedic Foot and Ankle Society (AOFAS) score and Visual Analogue Scale (VAS) for patient general satisfaction. The condition of the screw (removed, intact or broken), presence of radiolucency around the syndesmotic screw and the tibiofibular clear space were recorded using final follow-up radiographs. Three cortices were engaged in 66 patients (80%) and quadricortical fixation was performed in the remaining 16 patients (20%). The number of engaged cortices did not correlate with the clinical outcome and screw fracture. A single syndesmotic screw was used in 71 patients (86%. The mean AOFAS score in the group with intact screw (I) was 83; the scores in the group with broken screw (B) and removed screw (R) were 92.5 and 85.5, respectively. There was a statistically significant difference between the three groups: this was due to the difference between groups I and B; the difference between groups I and R and groups B and R were not statistically significant. There were no statistically significant differences in VAS results. There were no statistically significant differences in clinical outcome between the group with the screw retained and the group in which the screw was removed; however, the

  10. Current concepts review: Fractures of the patella

    Science.gov (United States)

    Gwinner, Clemens; Märdian, Sven; Schwabe, Philipp; Schaser, Klaus-D.; Krapohl, Björn Dirk; Jung, Tobias M.

    2016-01-01

    Fractures of the patella account for about 1% of all skeletal injuries and can lead to profound impairment due to its crucial function in the extensor mechanism of the knee. Diagnosis is based on the injury mechanism, physical examination and radiological findings. While the clinical diagnosis is often distinct, there are numerous treatment options available. The type of treatment as well as the optimum timing of surgical intervention depends on the underlying fracture type, the associated soft tissue damage, patient factors (i.e. age, bone quality, activity level and compliance) and the stability of the extensor mechanism. Regardless of the treatment method an early rehabilitation is recommended in order to avoid contractures of the knee joint capsule and cartilage degeneration. For non-displaced and dislocated non-comminuted transverse patellar fractures (2-part) modified anterior tension band wiring is the treatment of choice and can be combined – due to its biomechanical superiority – with cannulated screw fixation. In severe comminuted fractures, open reduction and fixation with small fragment screws or new angular stable plates for anatomic restoration of the retropatellar surface and extension mechanism results in best outcome. Additional circular cerclage wiring using either typical metal cerclage wires or resorbable PDS/non-resorbable FiberWires increases fixation stability and decreases risk for re-dislocation. Distal avulsion fractures should be fixed with small fragment screws and should be protected by a transtibial McLaughlin cerclage. Partial or complete patellectomy should be regarded only as a very rare salvage operation due to its severe functional impairment. PMID:26816667

  11. Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation.

    Science.gov (United States)

    Lujan, Trevor J; Henderson, Chris E; Madey, Steven M; Fitzpatrick, Dan C; Marsh, J Lawrence; Bottlang, Michael

    2010-03-01

    Locked plating constructs may be too stiff to reliably promote secondary bone healing. This study used a novel imaging technique to quantify periosteal callus formation of distal femur fractures stabilized with locking plates. It investigated the effects of cortex-to-plate distance, bridging span, and implant material on periosteal callus formation. Retrospective cohort study. One Level I and one Level II trauma center. Sixty-four consecutive patients with distal femur fractures (AO types 32A, 33A-C) stabilized with periarticular locking plates. Osteosynthesis using indirect reduction and bridge plating with periarticular locking plates. Periosteal callus size on lateral and anteroposterior radiographs. Callus size varied from 0 to 650 mm2. Deficient callus (20 mm2 or less) formed in 52%, 47%, and 37% of fractures at 6, 12, and 24 weeks postsurgery, respectively. Callus formation was asymmetric, whereby the medial cortex had on average 64% more callus (P=0.001) than the anterior or posterior cortices. A longer bridge span correlated minimally with an increased callus size at Week 6 (P=0.02), but no correlation was found at Weeks 12 and 24 postsurgery. Compared with stainless steel plates, titanium plates had 76%, 71%, and 56% more callus at Week 6 (P=0.04), Week 12 (P=0.03), and Week 24 (P=0.09), respectively. Stabilization of distal femur fractures with periarticular locking plates can cause inconsistent and asymmetric formation of periosteal callus. A larger bridge span only minimally improves callus formation. The more flexible titanium plates enhanced callus formation compared with stainless steel plates.

  12. First Metatarsophalangeal Joint Arthrodesis in Hallux Valgus Versus Hallux Rigidus Using Cup and Cone Preparation Compression Screw and Dorsal Plate Fixation.

    Science.gov (United States)

    Chien, Calvin; Alfred, Terrence; Freihaut, Richard; Pit, Sabrina

    2017-10-19

    Various techniques have been described for first metatarsophalangeal (MTP) joint arthrodesis. The purpose of this study was to determine if cup and cone preparation by a single surgeon with an interfragmentary screw and dorsal plate fixation provides a comparable union rate in hallux valgus versus hallux rigidus. Our study included all patients who underwent first MTP joint fusions using cup and cone preparation with an interfragmentary compression screw and dorsal plate fixation from 2010 to 2015. We compared union rates in 65 patients with hallux rigidus with 47 who had hallux valgus. One of 65 hallux rigidus cases developed non-union and underwent revision surgery. One of 47 patients in the hallux valgus group developed a painless non-union. All other patients achieved union based on post operative radiographs. Our rate of painful non-union was 1.5% for hallux rigidus and 0% for hallux valgus, which is lower than recent published literature of 7% for hallux valgus and 3.7% for hallux rigidus. We found no difference between the two groups suggesting this method may provide stronger fixation and may be preferable when dealing with hallux valgus. First metatarsophalangeal joint fusion in patients with severe hallux valgus and hallux rigidus, using spherical reamers, compression screw and dorsal plate fixation is equally successful at achieving clinical and radiographic fusion in both hallux valgus and hallux rigidus.

  13. A PROSPECTIVE STUDY ON FUNCTIONAL OUTCOME OF HUMERUS SHAFT FRACTURES TREATED WITH OPEN REDUCTION AND INTERNAL FIXATION WITH DYNAMIC COMPRESSION PLATE AND SCREWS

    Directory of Open Access Journals (Sweden)

    Vidyadhar S. Donimath

    2017-12-01

    Full Text Available BACKGROUND Fracture of the humerus shaft accounts to 3% to 5% of all fractures. Majority of the fractures are unstable due to distraction force of the gravity in the upper limb and strong muscle contraction leading to displacement. Internal fixation and early mobilisation is more stressed on than splinting and prolonged immobilisation to allow earlier mobilisation and rapid return to work. The aim of the study was to study the union rates and the functional outcome and complications associated with shaft humerus fractures in KIMS Hospital. MATERIALS AND METHODS A prospective study which was carried out from October 2015 to September 2017 in Karnataka Institute of Medical Sciences, Hubballi, Karnataka State, India. In this study period, 25 cases of fracture shaft of the humerus were treated by open reduction and internal fixation using DCP. Skeletally mature patients with fresh humerus diaphysis fractures were included in the study. Pathological fractures and Tscherne grade 2 and above, Gustilo Anderson type2 and above were excluded from the study. RESULTS In our series of 25 cases, there were 21 men and 4 women with average age of 42.5 years. Sixteen (64% cases were due to RTA and with predominance of right side. Transverse fractures were most common that is 15 (60% patients. Eleven (31% cases were having associated injuries. 92% of the fractures united with good to excellent outcome. There were 2 (8% cases of non-union due to infection and comminution. CONCLUSION Open reduction and internal fixation with dynamic compression plate is still the standard treatment of choice for fracture shaft of humerus achieving excellent to good functional outcome.

  14. Autotransplantation of Mandibular Third Molar with Buccal Cortical Plate to Replace Vertically Fractured Mandibular Second Molar: A Novel Technique.

    Science.gov (United States)

    Zufía, Juan; Abella, Francesc; Trebol, Ivan; Gómez-Meda, Ramón

    2017-09-01

    Tooth replacement often leads to inadequate vertical volume in the recipient site bone when a tooth has been extracted because of a vertical root fracture (VRF). This case report presents the autotransplantation of a mandibular third molar (tooth #32) with the attached buccal cortical plate to replace a mandibular second molar (tooth #31) diagnosed with a VRF. After extraction of tooth #31, the recipient socket was prepared based on the size measured in advance with cone-beam computed tomographic imaging. The precise and calculated osteotomy of the cortical bone of tooth #32 allowed for the exact placement of the donor tooth in the position of tooth #31. The total extraoral time was only 25 minutes. The block was fixed to the recipient socket with an osteosynthesis screw and splinted with a double resin wire for 8 weeks. At the 6-month follow-up, the screw was removed, and the stability of the tooth and the regeneration obtained throughout the vestibular area were confirmed. At the 2-year follow-up, the transplanted tooth was asymptomatic and maintained a normal bone level. Advantages of autotransplantation over dental implants include maintenance of proprioception, possible orthodontic movements, and a relatively low cost. This case report demonstrates that an autotransplantation of a third molar attached to its buccal cortical plate is a viable option to replace teeth with a VRF. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. The Effect of Polymethyl Methacrylate Augmentation on the Primary Stability of Cannulated Bone Screws in an Anterolateral Plate in Osteoporotic Vertebrae: A Human Cadaver Study.

    Science.gov (United States)

    Rüger, Matthias; Sellei, Richard M; Stoffel, Marcus; von Rüden, Christian

    2016-02-01

    Study Design Cohort study. Objective Expandable anterolateral plates facilitate the reduction of posttraumatic deformities of thoracolumbar spine injuries and are commonly used in cases of unstable injuries or compromised bone quality. In this in vitro study, the craniocaudal yield load of the osseous fixation of an anterior angular stable plate fixation system and the effect of polymethyl methacrylate (PMMA) screw augmentation on the primary stability of the screw-bone interface during kyphosis reduction was evaluated in 12 osteoporotic human thoracolumbar vertebrae. Methods The anterolateral stabilization device used for this study is comprised of two swiveling flanges and an expandable midsection. It facilitates the controlled reduction of kyphotic deformities in situ with a geared distractor. Single flanges were attached to 12 thoracolumbar vertebrae. Six specimens were augmented with PMMA by means of cannulated bone screws. The constructs were subjected to static, displacement-controlled craniocaudal loading to failure in a servohydraulic testing machine. Results The uncemented screws cut out at a mean 393 ± 66 N, whereas the cemented screws showed significantly higher yield load of 966 ± 166 N (p augmentation is an effective method to increase two- to threefold the primary stability of the screw-bone interface of an anterolateral spine stabilization system in osteoporotic bone. We recommend it in cases of severely compromised bone quality to reduce the risk of screw loosening during initial kyphosis correction and to increase long-term construct stability.

  16. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis.

    Science.gov (United States)

    Kim, Ji Wan; Oh, Chang-Wug; Byun, Young-Soo; Kim, Jung Jae; Park, Ki Chul

    2015-04-01

    To compare the clinical and radiologic results of conventional open plating (COP) and minimally invasive plate osteosynthesis (MIPO) in the treatment of noncomminuted humeral shaft fractures. Randomized prospective study. Five level 1 trauma centers. Sixty-eight consecutive patients were randomized into 2 study groups: those treated by COP (COP group; n = 32) and those treated by MIPO (MIPO group; n = 36). Simple humeral shaft fractures (AO/OTA classification types A and B) were reduced by open reduction or closed reduction and fixed with a narrow 4.5/5.0 locking compression plate, metaphyseal locking compression plate, or proximal humeral internal locking system plate to the anterior lateral aspect of the humerus. Fracture healing time, operative time, radiation exposure time, and intraoperative nerve injury. To assess shoulder and elbow function, we used the University of California, Los Angeles (UCLA) scoring system and the Mayo elbow performance index, including the range of motion and pain. Radiographic measurements included fracture alignment, delayed union, and nonunion. Thirty-one fractures (97%) healed in the COP group within 16 weeks, whereas 36 fractures (100%) were healed in the MIPO group by 15 weeks. No significant difference was observed in the operative time or complication rates. In both groups, all fractures achieved union without malunion and with excellent functional outcomes by definition of the Mayo elbow performance index and UCLA scoring system. This study confirmed a high overall rate of union and excellent functional outcomes in both MIPO and COP groups. MIPO is equivalent to COP as a safe and effective method for simple types of humeral shaft fractures when surgery is indicated, and the surgeon is experienced in the technique. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

  17. Water-cooled non-thermal gliding arc for adhesion improvement of glass-fibre-reinforced polyester

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Sørensen, Bent F.; Løgstrup Andersen, Tom

    2013-01-01

    A non-equilibrium quenched plasma is prepared using a gliding-arc discharge generated between diverging electrodes and extended by a gas flow. It can be operated at atmospheric pressure and applied to plasma surface treatment to improve adhesion properties of material surfaces. In this work, glass......-fibre-reinforced polyester plates were treated using an atmospheric pressure gliding-arc discharge with air flow to improve adhesion with a vinylester adhesive. The electrodes were water-cooled so as to operate the gliding arc continually. The treatment improved wettability and increased the density of oxygen...

  18. Conservative treatment of a mandibular condyle fracture: comparing intermaxillary fixation with screws or arch bar. A randomised clinical trial

    NARCIS (Netherlands)

    van den Bergh, B.; Blankestijn, J.; van der Ploeg, T.; Tuinzing, D.B.; Forouzanfar, T.

    2015-01-01

    Introduction A mandibular condyle fracture can be treated conservatively by intermaxillary fixation (IMF) or by open reposition and internal fixation (ORIF). Many IMF-modalities can be chosen, including IMF-screws (IMFS). This prospective multi-centre randomised clinical trial compared the use of

  19. Conservative treatment of a mandibular condyle fracture: Comparing intermaxillary fixation with screws or arch bar. A randomised clinical trial

    NARCIS (Netherlands)

    van den Bergh, B.; Blankestijn, J.; van der Ploeg, T.; Tuinzing, D.B.; Forouzanfar, T.

    2015-01-01

    Introduction A mandibular condyle fracture can be treated conservatively by intermaxillary fixation (IMF) or by open reposition and internal fixation (ORIF). Many IMF-modalities can be chosen, including IMF-screws (IMFS). This prospective multi-centre randomised clinical trial compared the use of

  20. [Odontoid bending stiffness after anterior fixation with a single lag screw: biomechanical study].

    Science.gov (United States)

    Buchvald, P; Čapek, L; Barsa, P

    2015-01-01

    PURPOSE OF THE STUDY The aim of the experiment was to compare the bending stiffness of an intact odontoid process with bending stiffness after its simulated type II fracture was fixed with a single lag screw. The experiment was done with a desire to answer the question of whether a single osteosynthetic screw is sufficient for good fixation of a type II odontoid fracture. MATERIAL AND METHODS The C2 vertebrae of six cadavers were used. With simultaneous measurement of odontoid bending stiffness, the occurrence of a fracture (type IIA, Grauer's modification of the Anderson- D'Alonzo classification) was simulated using action exerted by a tearing machine in the direction perpendicular to the odontoid axis. Each odontoid fracture was subsequently treated by direct osteosynthesis with a single lag screw inserted in the axial direction by a standard surgical procedure in order to provide conditions similar to those achieved by routine surgical management. The treated odontoid process was subsequently subjected to the same tearing machine loading as applied to it at the start of the experiment. The bending stiffness measured was then compared with that found before the fracture occurred. The results were statistically evaluated by the t-test for paired samples at the level of significance α = 0.05. RESULTS The average value of bending stiffness for odontoid processes of intact vertebrae at the moment of fracture occurrence was 318.3 N/mm. After single axial lag screw fixation of the fracture, the average bending stiffness for the odontoid processes treated was 331.3 N/mm. DISCUSSION Higher values of bending stiffness after screw fixation were found in all specimens and, in comparison with the values recorded before simulated fractures, the increase was statistically significant. CONCLUSIONS The results of our measurements suggest that the single lag screw fixation of a type IIA odontoid fracture will provide better stability for the fracture fragment-C2 body complex on

  1. Relationship between plate removal and Soong grading following surgery for fractured distal radius

    NARCIS (Netherlands)

    Selles, Caroline A.; Reerds, Sam T. H.; Roukema, Gert; van der Vlies, Kees H.; Cleffken, Berry I.; Schep, Niels W. L.

    2018-01-01

    The aim of this study was to determine the relationship between volar plate removal and the Soong classification following fixation for fractured distal radius. In this retrospective cohort study, all consecutive patients who had volar plate fixation for a distal radius fracture in 2011-2015 were

  2. Dynamic compression plate (DCP) fixation of propagating medial condylar fractures of the third metacarpal/metatarsal bone in 30 racehorses: retrospective analysis (1990-2005).

    Science.gov (United States)

    Goodrich, L R; Nixon, A J; Conway, J D; Morley, P S; Bladon, B M; Hogan, P M

    2014-11-01

    An in-depth review of dynamic compression plate (DCP) fixation of propagating medial condyle fractures of the third metacarpus or metatarsus has not been previously reported. To describe the technique, evaluate short-term outcome and long-term race performance of racehorses that underwent DCP fixation for repair of propagating or spiralling medial condylar fractures of the third metacarpal (McIII) or metatarsal (MtIII) bone. Retrospective case series. The surgical case records of 30 horses with propagating fractures of the medial condyle of McIII or MtIII were reviewed. Medical information included: age, breed, sex, presentation, how injury occurred (racing or training), surgical treatment and post operative complications. Racing information included: starts, top 3 placing and career earnings. Long propagating fractures of the medial condyle of Mc/tIII were identified in 23 Thoroughbred (TB) and 7 Standardbred (STB) racehorses. The fracture spiralled proximally in 22 of 30 cases (73%). Standardbreds had a higher propensity for hindlimb involvement (71%), whereas TBs tended to have more front limb involvement (61%). Twelve of 30 (40%) horses raced post surgery. Career earnings were significantly lower for TB horses with medial condylar fractures; $34,916 when compared with the national average of $60,841 (P≤0.03). Overall, horses having DCP fixation for medial condylar fractures had less starts post surgery (3.1 TBs and 5.8 STBs) compared with the national average (7 TBs and 17.3 STBs) and decreased lifetime starts 13.4 (TBs) compared with 17.3 nationally. Propagating medial condyle fractures can be repaired with plate fixation to potentially lessen the risk of catastrophic fracture destabilisation and return to racing can be expected in 40% of horses. Further prospective studies are warranted comparing lag screw fixation with DCP fixation for repair of severe medial condylar fractures of the metacarpus/metatarsus. © 2013 The Authors. Equine Veterinary Journal

  3. Unstable recent intracapsular femoral neck fractures in young adults: Osteosynthesis and primary valgus osteotomy using broad dynamic compression plate

    Directory of Open Access Journals (Sweden)

    Singh M

    2008-01-01

    Full Text Available Background: Displaced intracapsular femoral neck fractures continue to be a difficult problem to treat. Various treatment modalities and their modifications have been proposed to improve the outcome. Osteosynthesis and primary valgus angulation osteotomy is one of them. Technique and outcome in a consecutive series of recent intracapsular femoral neck fractures in young adults, from a single center, is presented. Materials and Methods: Fifty-five patients of recent (< 3 weeks old displaced intracapsular fracture neck femur (Garden III and IV, Pauwels III, with or without comminution in the age group 20-50 years (mean 35.4±10.4 years were subjected to osteosynthesis and primary valgus intertrochanteric osteotomy using contoured broad dynamic compression plate (DCP. The patients were followed up from two to six years (mean 4.6 years. Results: Fifty-one fractures united by six months of the index procedure (92.7% union range. Avascular necrosis (AVN developed in six patients (11%. The other complications were shortening (six, coxa vara (two, infection (two and delayed union at osteotomy site (one. Excellent results were achieved in 48, good/fair in four and poor in three patients. Conclusion: Osteosynthesis with cancellous screw and primary valgus intertrochanteric osteotomy stabilized by a contoured broad DCP is a simple, easy to perform, biological treatment. Failure in a particular case can be treated with any appropriate second procedure. Level of Evidence: IV

  4. Operative fixation of chest wall fractures: an underused procedure?

    Science.gov (United States)

    Richardson, J David; Franklin, Glen A; Heffley, Susan; Seligson, David

    2007-06-01

    Chest wall fractures, including injuries to the ribs and sternum, usually heal spontaneously without specific treatment. However, a small subset of patients have fractures that produce overlying bone fragments that may produce severe pain, respiratory compromise, and, if untreated mechanically, result in nonunion. We performed open reduction and internal fixation on seven patients with multiple rib fractures-five in the initial hospitalization and two delayed--as well as 35 sternal fractures (19 immediate fixation and 16 delayed). Operative fixation was accomplished using titanium plates and screws in both groups of patients. All patients with rib fractures did well; there were no major complications or infections, and no plates required removal. Clinical results were excellent. There was one death in the sternal fracture group in a patient who was ventilator-dependent preoperatively and extubated himself in the early postoperative period. Otherwise, the results were excellent, with no complications occurring in this group. Three patients had their plates removed after boney union was achieved. No evidence of infection or nonunion occurred. The excellent results achieved in the subset of patients with severe chest wall deformities treated initially at our institution and those referred from outside suggest that operative fixation is a useful modality that is likely underused.

  5. Cyclic fatigue resistance of R-Pilot, WaveOne Gold Glider, and ProGlider glide path instruments.

    Science.gov (United States)

    Keskin, Cangül; İnan, Uğur; Demiral, Murat; Keleş, Ali

    2018-02-17

    The aim of the present study was to compare the cyclic fatigue resistance of R-Pilot (VDW; Munich, Germany) with ProGlider (Denstply Sirona; Ballaigues, Switzerland) and WaveOne Gold Glider (Denstply Sirona; Ballaigues, Switzerland) glide path instruments. R-Pilot, ProGlider, and WaveOne Gold Glider instruments were collected (n = 15) and tested in a dynamic cyclic fatigue test device, which has an artificial canal with 60° angle of curvature and a 5-mm radius of curvature. All instruments were operated until fracture occurred, and both time to fracture (TF) and the lengths of the fractured fragments were recorded. Mean and standard deviations of TF and fragment length were calculated for each reciprocating system. TF data and fractured fragment length data were subjected to one-way ANOVA and post-hoc Tukey tests (P  0.05). Weibull analysis revealed that WaveOne Gold Glider showed the highest predicted TF value for 99% survival rate, which was followed by R-Pilot and ProGlider. Regarding the length of the fractured tips, there were no significant differences among the instruments (P > 0.05). The reciprocating WaveOne Gold Glider and R-Pilot instruments had significantly higher cyclic fatigue resistance than rotary ProGlider instruments. This study reported that novel reciprocating glide path instruments exhibited higher cyclic fatigue resistance than rotating glide path instrument.

  6. Clinical efficacy of open reduction and semirigid internal fixation in management of displaced pediatric mandibular fractures: A series of 10 cases and surgical guidelines

    OpenAIRE

    Samir Joshi; Rajesh Kshirsagar; Akshay Mishra; Rahul Shah

    2015-01-01

    Aim: To evaluate the efficacy of open reduction and semirigid internal fixation in the management of displaced pediatric mandibular fractures. Method: Ten patients with displaced mandibular fractures treated with 1.5 mm four holed titanium mini-plate and 4 mm screws which were removed within four month after surgery. Results: All cases showed satisfactory bone healing without any growth disturbance. Conclusion: Open reduction and rigid internal fixation (ORIF) with 1.5 mm titanium mini- plate...

  7. The Use of a Reciprocating Handpiece to Create a Glide Path in Curved Canals: Comparison with Manual Glide Path Preparation

    Science.gov (United States)

    2016-06-01

    instruments into the root canal system, manufacturers recommend creating a glide path to reduce the risk of instrument fracture due to taper lock . This...Results The two groups had almost identical mean and standard...The groups had identical median values of 85 seconds, and there was no significant difference between the groups (Mann-Whitney U test; p=0.15; two

  8. Fretting corrosion tests on orthopedic plates and screws made of ASTM F138 stainless steel

    OpenAIRE

    Santos,Claudio Teodoro dos; Barbosa,Cássio; Monteiro,Maurício de Jesus; Abud,Ibrahim de Cerqueira; Caminha,Ieda Maria Vieira; Roesler,Carlos Rodrigo de Mello

    2015-01-01

    Introduction Although there has been significant progress in the design of implants for osteosynthesis, the occurrence of failures in these medical devices are still frequent. These implants are prone to suffer from fretting corrosion due to micromotion that takes place between the screw heads and plate holes. Consequently, fretting corrosion has been the subject of research in order to understand its influence on the structural integrity of osteosynthesis implants. The aim of this paper is t...

  9. Evaluation of shoulder and elbow functions after treatment of humeral shaft fractures: a 20-132-month follow-up study.

    Science.gov (United States)

    Fırat, Ahmet; Deveci, Alper; Güler, Ferhat; Oçgüder, Ali; Oğuz, Temel; Bozkurt, Murat

    2012-01-01

    The aim of this study was to evaluate the long-term results of shoulder and elbow functions in humeral shaft fractures treated with functional brace, plate and screw osteosynthesis or intramedullary nailing. The study included 128 patients treated for humeral shaft fracture. The patients were divided into three groups according to treatment method: Group 1 (n=62) received functional brace, Group 2 (n=36) plate and screw osteosynthesis and Group 3 (n=30) intramedullary nailing. Coronal and sagittal humeral angulations were measured radiologically during the final follow-up. Shoulder and elbow functions were evaluated using the Constant shoulder score, the Mayo Elbow Performance Scoring and range of movement measurements. The mean follow-up time was 74 (range: 20 to 132) months. Mean Constant shoulder scores were 92.4 in Group 1, 85.6 in Group 2 and 74 in Group 3. A statistically significant difference was detected between the Constant shoulder scores of Groups 2 and 3 (p0.05). In the statistical evaluation of the Constant shoulder scores, a statistically significant difference was detected between the Constant scores of patients with a varus angulation greater than 20° and those with neutral alignment. Functional results of humeral shaft fractures treated with functional brace appear to be satisfactory. Varus and antecurvatum may affect shoulder and elbow function. In the presence of surgical indications, plate and screw fixation technique is the most effective method in terms of shoulder and elbow functions.

  10. Comparative study of two materials for dynamic hip screw during fall and gait loading: titanium alloy and stainless steel.

    Science.gov (United States)

    Taheri, Nooshin S; Blicblau, Aaron S; Singh, Manmohan

    2011-11-01

    Internal fixation with dynamic hip screw is a choice of treatment for hip fractures to stabilize a femoral fracture. Choosing the proper implant and its material has a great effect on the healing process and failure prevention. The purpose of this analysis was to assess biomechanical behavior of dynamic hip screw with two different materials implanted in the femur during fall and gait. A 3D finite element model of an intact femur and a 3D implant within the same femur were developed. A finite element analysis was carried out to establish the effect of load conditions and implant material properties on biomechanical behavior of the dynamic hip screw after internal fixation. Two load configurations are chosen: one simulating the stance phase of the normal gait cycle, and the other replicating a low-energy fall. The implanted femur was investigated with two different materials for the dynamic hip screw: stainless steel and titanium alloy. During stance, more stress is placed on the implanted femur compared with the intact femur. During a fall, the implanted femur is in a greater state of stress, which mostly occurs inside the dynamic hip screw. Titanium alloy decreases stress levels by an average of 40% compared with stainless steel. However, deformation is slightly reduced with a stainless steel dynamic hip screw during both load cases. After internal fixation, dynamic hip screw generates greater stresses within the implanted femur compared with the intact femur under the same loading conditions. A titanium alloy implant appears to undergo less stress from a low-energy fall compared with stainless steel and can be considered the preferred implant material. The critical parts of the dynamic hip screw are the forth distal screw and the plate.

  11. Femoral fracture repair using a locking plate technique in an adult captive polar bear (Ursus maritimus).

    Science.gov (United States)

    Zimmerman, Dawn M; Dew, Terry; Douglass, Michael; Perez, Edward

    2010-02-01

    To report successful femoral fracture repair in a polar bear. Case report. Female polar bear (Ursus maritimus) 5 years and approximately 250 kg. A closed, complete, comminuted fracture of the distal midshaft femur was successfully reduced and stabilized using a compression plating technique with 2 specialized human femur plates offering axial, rotational, and bending support, and allowing the bone to share loads with the implant. Postoperative radiographs were obtained at 11.5 weeks, 11 months, and 24 months. Bone healing characterized by marked periosteal reaction was evident at 11 months with extensive remodeling evident at 24 months. No complications were noted. Distal mid shaft femoral fracture was reduced, stabilized, and healed in an adult polar bear with a locking plate technique using 2 plates. Previously, femoral fractures in polar bears were considered irreparable. Use of 2 plates applied with a locking plate technique can result in successful fracture repair despite large body weight and inability to restrict postoperative activity.

  12. [Comparative study on the strength of different mechanisms of operation of multidirectionally angle-stable distal radius plates].

    Science.gov (United States)

    Rausch, S; Hoffmeier, K; Gueorguiev, B G; Klos, K; Gras, F; Hofmann, G O; Mückley, T

    2011-12-01

    Polyaxial angle-stable plating is thought to be particularly beneficial in the management of complex intra-articular fractures of the distal radius. The present study was performed to investigate the strength of polyaxial locking interfaces of distal radius plates. We tested the polyaxial interfaces of 3 different distal radius plates (2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plate, Synthes, Palmar Classic, Königsee Implantate and VariAx Plate Stryker). The strength of 0° and 10° screw locking angle was obtained during static loading. The strength of Palmar Classic with a 0° locking angle is significantly the best of all tested systems. With a 10° locking angle there is no significant difference between Palmar Classic, Two column Plate and VariAx Plate. The strength of polyaxial interfaces differs between the tested systems. A reduction of ultimate strength is due to increases of screw locking angle. The design of polyaxial locking interfaces should be investigated in human bone models. © Georg Thieme Verlag KG Stuttgart · New York.

  13. A radial holding device for the bundle and brace plates envelope in a vapor generator, by the means of enclosed screw stops

    International Nuclear Information System (INIS)

    Comic, G.

    1995-01-01

    With the aim to protect the envelopes and bundles against seisms or other constraints, without causing interference with the water flow or being too complicated to install, as with previous systems, a holding system is proposed which uses screw stops fixed to the envelope and to the brace; the screw, enclosed in one of the two parts, ensures, during the assembly, the displacement of the second part for good contact with the brace plate. 6 fig

  14. [Surgery of ipsilateral Hawkins Ⅲ talus neck and ankle joint fractures via internal and lateral approaches with Herbert screws].

    Science.gov (United States)

    Zhang, P; Dong, Q R; Wang, Z Y; Chen, B; Wan, J H; Wang, L

    2016-11-08

    Objective: To explore the manual operation skills of operative treatment of ipsilateral Hawkins Ⅲ talus neck and ankle joint fractures via internal and lateral approaches with Herbert screws, and to study the clinical results. Method: From Jan 2009 to Dec 2014, the clinical data of 13 patients with ipsilateral Hawkins Ⅲ talus neck and ankle joint fractres via internal and lateral approaches with Herbert screws were retrospectively analyzed in our department.There were 10 males and 3 female, ranging in age from 20 to 60 years with an average age of 31.5 years.The fractures occurred on the right side in 9 patients and on the left side in 4 patients.Three cases had the complication of medial malleolar fracture.Ten cases had the complication of medial and lateral malleolar fracture. Totally 11 cases were made calcaneal skeletal traction, and all the were made CT with three-dimensional image reconstruction.Two cases were treated with emergency operation.Eleven cases were treated with selective operation.The operation time was 5 hours-10 days after injury. The functional results were evaluated by American Orthopaedic Foot and Ankle Society (AOFAS). Result: The average duration of follow-up was 22.6 months (range, 14-65 months). There was skin necrosis in one cases, no incision infection, malunion and nonunion of the fractures and loss of reduction. At final follow-up, AOFAS ankle score was 75.2 (range, 42 to 93), higher than preoperative 39.2 (range, 23 to 60), the difference was statistically significant ( P =0.023). The result was excellent in 4 cases, good in 5 cases, fair in 3 cases and 1 cases in poor, and the overall excellent or good rate was 69.2%. Avascular necrosis occurred in 3 cases (23.1%, 3/13). Traumatic arthritis was found in 5 cases (38.5%, 5/13), involved tibial astragaloid joint in 2 cases, involved subtalar joint in 1 case, involved tibial astragaloid joint and subtalar joint in 2 cases. Conclusion: The effect of surgical treatment for ipsilateral

  15. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.

    Science.gov (United States)

    Vidović, Dinko; Matejčić, Aljoša; Ivica, Mihovil; Jurišić, Darko; Elabjer, Esmat; Bakota, Bore

    2015-11-01

    Distal tibial or pilon fractures are usually the result of combined compressive and shear forces, and may result in instability of the metaphysis, with or without articular depression, and injury to the soft tissue. The complexity of injury, lack of muscle cover and poor vascularity make these fractures difficult to treat. Surgical treatment of distal tibial fractures includes several options: external fixation, IM nailing, ORIF and minimally-invasive plate osteosynthesis (MIPO). Management of distal tibial fractures with MIPO enables preservation of soft tissue and remaining blood supply. This is a report of a series of prospectively studied closed distal tibial and pilon fractures treated with MIPO. A total of 21 patients with closed distal tibial or pilon fractures were enrolled in the study between March 2008 and November 2013 and completed follow-up. Demographic characteristics, mechanism of injury, time required for union, ankle range of motion and complications were recorded. Fractures were classified according to the AO/OTA classification. Nineteen patients were initially managed with an ankle-spanning external fixator. When the status of the soft tissue had improved and swelling had subsided enough, a definitive internal fixation with MIPO was performed. Patients were invited for follow-up examinations at 3 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months. Mean age of the patients was 40.1 years (range 19-67 years). Eighteen cases were the result of high-energy trauma and three were the result of low-energy trauma. According to the AO/OTA classification there were extraarticular and intraarticular fractures, but only simple articular patterns without depression or comminution. The average time for fracture union was 19.7 weeks (range 12-38 weeks). Mean range of motion was 10° of dorsiflexion (range 5-15°) and 28.3° of plantar flexion (range 20-35°). Three cases were metalwork-related complications. Two patients underwent plate removal

  16. A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture.

    Science.gov (United States)

    Liang, Bowei; Ding, Zhenqi; Shen, Junguo; Zhai, Wenliang; Kang, Liangqi; Zhou, Liang; Sha, Mo; Liang, Dongzhu

    2012-08-01

    An anatomical supra-condylar plate is designed and analysed by biomechanical testing. The biomechanical properties of the supra-condylar and condylar plate were compared in six matched pairs of cadaveric femurs. A transverse osteotomy gap was created to simulate an OTA/AO type A3 supracondylar fracture. The left and right specimens were fitted with supra-condylar and condylar plate, respectively. Nondestructive axial compression, three-point bending and torsion tests were performed, and the peak load of the bone-implant construction was measured. The fracture site suitable for supra-condylar plate application and its correlation with femoral length were calculated. The gender influence on it was also discussed. The difference of stiffness between the supra-condylar and condyle groups were not significant (P > 0.05) at 363.4 and 362.5 N/mm for compression, 229.5 and 237.6 N/mm in the sagittal plane and 195.5 and 188.4 N/mm in the coronal plane for three-point bending, and 7.5 and 7.9 Nm/deg for axial torsion, respectively. The peak load was 4438 ± 136.15 N and 5215 ± 174.33 N, respectively, for the two groups. The average extent of the fracture site suitable for the application of the supra-condylar plate was 70.86 ± 4.61 mm. The femoral length and gender showed no influence on it. Despite the limited bone contact area provided by the supra-condylar plate, its construct stiffness is comparable to the condylar plate. The supra-condylar plate can be used to treat carefully-selected extra-articular supracondylar fractures.

  17. Assessing the importance of terrain parameters on glide avalanche release

    Science.gov (United States)

    Peitzsch, E.; Hendrikx, J.; Fagre, D. B.

    2013-12-01

    avalanches failed as cohesive slabs on this bedrock surface. Consequently, surface roughness proved to be a useful descriptive variable to discriminate between slopes that avalanched and those that did not. Annual 'repeat offender' glide avalanche paths were characterized by smooth outcropping rock plates with stratification planes parallel to the slope. Combined with aspect these repeat offenders were also members of the highest glide category. Using this understanding of the role of topographic parameters on glide avalanche activity, a spatial terrain based model was developed to identify other areas with high glide avalanche potential outside of our immediate observation area.

  18. Assessing the importance of terrain parameters on glide avalanche release

    Science.gov (United States)

    Peitzsch, Erich H.; Hendrikx, Jordy; Fagre, Daniel B.

    2014-01-01

    avalanches failed as cohesive slabs on this bedrock surface. Consequently, surface roughness proved to be a useful descriptive variable to discriminate between slopes that avalanched and those that did not. Annual 'repeat offender' glide avalanche paths were characterized by smooth outcropping rock plates with stratification planes parallel to the slope. Combined with aspect these repeat offenders were also members of the highest glide category. Using this understanding of the role of topographic parameters on glide avalanche activity, a spatial terrain based model was developed to identify other areas with high glide avalanche potential outside of our immediate observation area.

  19. UK DRAFFT - A randomised controlled trial of percutaneous fixation with kirschner wires versus volar locking-plate fixation in the treatment of adult patients with a dorsally displaced fracture of the distal radius

    Directory of Open Access Journals (Sweden)

    Brown Jaclyn

    2011-09-01

    Full Text Available Abstract Background Fractures of the distal radius are extremely common injuries in adults. However, the optimal management remains controversial. In general, fractures of the distal radius are treated non-operatively if the bone fragments can be held in anatomical alignment by a plaster cast or orthotic. However, if this is not possible, then operative fixation is required. There are several operative options but the two most common in the UK, are Kirschner-wire fixation (K-wires and volar plate fixation using fixed-angle screws (locking-plates. The primary aim of this trial is to determine if there is a difference in the Patient-Reported Wrist Evaluation one year following K-wire fixation versus locking-plate fixation for adult patients with a dorsally-displaced fracture of the distal radius. Methods/design All adult patients with an acute, dorsally-displaced fracture of the distal radius, requiring operative fixation are potentially eligible to take part in this study. A total of 390 consenting patients will be randomly allocated to either K-wire fixation or locking-plate fixation. The surgery will be performed in trauma units across the UK using the preferred technique of the treating surgeon. Data regarding wrist function, quality of life, complications and costs will be collected at six weeks and three, six and twelve months following the injury. The primary outcome measure will be wrist function with a parallel economic analysis. Discussion This pragmatic, multi-centre trial is due to deliver results in December 2013. Trial registration Current Controlled Trials ISRCTN31379280 UKCRN portfolio ID 8956

  20. End-threaded intramedullary positive profile screw ended self-tapping pin (Admit pin) - A cost-effective novel implant for fixing canine long bone fractures.

    Science.gov (United States)

    Chanana, Mitin; Kumar, Adarsh; Tyagi, Som Prakash; Singla, Amit Kumar; Sharma, Arvind; Farooq, Uiase Bin

    2018-02-01

    The current study was undertaken to evaluate the clinical efficacy of end-threaded intramedullary pinning for management of various long bone fractures in canines. This study was conducted in two phases, managing 25 client-owned dogs presented with different fractures. The technique of application of end-threaded intramedullary pinning in long bone fractures was initially standardized in 6 clinical patients presented with long bone fractures. In this phase, end-threaded pins of different profiles, i.e., positive and negative, were used as the internal fixation technique. On the basis of results obtained from standardization phase, 19 client-owned dogs clinically presented with different fractures were implanted with end-threaded intramedullary positive profile screw ended self-tapping pin in the clinical application phase. The patients, allocated randomly in two groups, when evaluated postoperatively revealed slight pin migration in Group-I (negative profile), which resulted in disruption of callus site causing delayed union in one case and large callus formation in other two cases whereas no pin migration was observed in Group-II (positive profile). Other observations in Group-I was reduced muscle girth and delayed healing time as compared to Group-II. In clinical application, phase 21 st and 42 nd day post-operative radiographic follow-up revealed no pin migration in any of the cases, and there was no bone shortening or fragment collapse in end-threaded intramedullary positive profile screw ended self-tapping pin. The end-threaded intramedullary positive profile screw ended self-tapping pin used for fixation of long bone fractures in canines can resist pin migration, pin breakage, and all loads acting on the bone, i.e., compression, tension, bending, rotation, and shearing to an extent with no post-operative complications.

  1. [Application of three-dimensional printing in the operation of distal tibia fracture involving epiphyseal plate injury for teenagers].

    Science.gov (United States)

    Zhao, Jingxin; Ma, Yachang; Han, Dong; Jin, Yu

    2017-10-01

    To investigate the application value of three-dimensional (3-D) printing technology in the operation of distal tibia fracture involving epiphyseal plate injury for teenagers. The retrospective analysis was conducted on the clinical data of 16 cases of children patients with distal tibia fracture involving epiphyseal plate injury undergoing the operation by using of 3-D printing technology between January 2014 and December 2015. There were 12 males and 4 females with an age of 9-14 years (mean, 12.8 years). The causes of injury included traffic accident injury in 9 cases, heavy pound injury in 3 cases, and sport injury in 4 cases. The time from injury to operation was 3-92 hours (mean, 25.8 hours). According to Salter-Harris typing standard, the typing for epiphyseal injury was classified as type Ⅱ in 11 cases, type Ⅲ in 4 cases, and type Ⅳ in 1 case. The thin slice CT scan on the affected limb was performed before operation, and the Mimics14.0 medical software was applied for the design and the 1∶1 fracture model was printed by the 3-D printer; the stimulation of operative reduction was made in the fracture model, and bone plate, Kirschner wire, and hollow screw with the appropriate size were chosen, then the complete operative approach and method were designed and the internal fixator regimen was chosen, then the practical operation was performed based on the preoperative design regimen. The operation time was 40-68 minutes (mean, 59.1 minutes); the intraoperative blood loss was 5-102 mL (mean, 35 mL); the intraoperative fluoroscopy times was 2-6 times (mean, 2.8 times). All the patiens were followed up 12-24 months (mean, 15 months). The fracture of 15 cases reached anatomic reduction, and 1 cases had no anatomic reduction with the displaced end less than 1 mm. All the fractures reached bony union with the healing time of 2-4 months (mean, 2.6 months). There was no deep vein thrombosis, premature epiphyseal closure and oblique, or uneven ankle surface

  2. VA-LCP anterior clavicle plate: the anatomically precontoured fixation system with angular stability for clavicle shaft.

    Science.gov (United States)

    van Olden, G D J

    2014-12-01

    The aim of this investigation was to evaluate the introduction of the VA-LCP anterior clavicle plate in the treatment of clavicle fractures. From March 2011 to March 2013, 42 clavicle fractures were treated; 40 were middle-third and 2 lateral-third, and 13/42 (31 %) patients were treated due to painful nonunion. Patient age ranged from 16 to 81 years. Complications were screw placement through the AC-joint, one superficial wound infection and one neuropraxia of the nervus radialis with dropping hand. We had some difficulties prebending both lateral to low and lateral to high but without clinical consequences. In all cases, the fracture healed with full functionality. After 1 year, 4 patients underwent a removal of the hardware. The VA-LCP anterior plate showed good reliability and sufficient stability with both middle-third, lateral and nonunion fractures of the clavicle.

  3. Tension Band Plating for Chronic Anterior Tibial Stress Fractures in High-Performance Athletes.

    Science.gov (United States)

    Zbeda, Robert M; Sculco, Peter K; Urch, Ekaterina Y; Lazaro, Lionel E; Borens, Olivier; Williams, Riley J; Lorich, Dean G; Wellman, David S; Helfet, David L

    2015-07-01

    Anterior tibial stress fractures are associated with high rates of delayed union and nonunion, which can be particularly devastating to a professional athlete who requires rapid return to competition. Current surgical treatment strategies include intramedullary nailing, which has satisfactory rates of fracture union but an associated risk of anterior knee pain. Anterior tension band plating is a biomechanically sound alternative treatment for these fractures. Tension band plating of chronic anterior tibial stress fractures leads to rapid healing and return to physical activity and avoids the anterior knee pain associated with intramedullary nailing. Case series; Level of evidence, 4. Between 2001 and 2013, there were 13 chronic anterior tibial stress fractures in 12 professional or collegiate athletes who underwent tension band plating after failing nonoperative management. Patient charts were retrospectively reviewed for demographics, injury history, and surgical details. Radiographs were used to assess time to osseous union. Follow-up notes and phone interviews were used to determine follow-up time, return to training time, and whether the patient was able to return to competition. Cases included 13 stress fractures in 12 patients (9 females, 3 males). Five patients were track-and-field athletes, 4 patients played basketball, 2 patients played volleyball, and 1 was a ballet dancer. Five patients were Division I collegiate athletes and 7 were professional or Olympic athletes. Average age at time of surgery was 23.6 years (range, 20-32 years). Osseous union occurred on average at 9.6 weeks (range, 5.3-16.9 weeks) after surgery. Patients returned to training on average at 11.1 weeks (range, 5.7-20 weeks). Ninety-two percent (12/13) eventually returned to preinjury competition levels. Thirty-eight percent (5/13) underwent removal of hardware for plate prominence. There was no incidence of infection or nonunion. Anterior tension band plating for chronic tibial stress

  4. Short Segment Fixation Versus Short Segment Fixation With Pedicle Screws at the Fracture Level for Thoracolumbar Burst Fracture

    Directory of Open Access Journals (Sweden)

    Anghel S

    2014-04-01

    Full Text Available Objective: The most prevailing surgical procedure in the treatment of thoracolumbar burst fractures, Short Segment Fixation (SSF, is often followed by loss of correction or hardware failure which may be significant enough to require another surgical intervention. In order to take advantage of its benefits but to avoid or diminish the risk and impact of associated drawbacks, some other alternatives have been lately developed among which we refer to short segment fixation with intermediate screws (SSF+IS. This article provides a comparative picture over the effectiveness of the two above-mentioned surgical treatments, focusing on their potential to prevent the loss of correction.

  5. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    Science.gov (United States)

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  6. Traumatic fracture-dislocation of the hip following rugby tackle: a case report

    Directory of Open Access Journals (Sweden)

    Venkatachalam Santosh

    2009-12-01

    Full Text Available Abstract Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months.

  7. Avulsion Fracture of the Calcaneus Treated With a Soft Anchor Bridge and Lag Screw Technique: A Report of Two Cases.

    Science.gov (United States)

    Yoshida, Kazushige; Kasama, Kentaro; Akahane, Tsutomu

    2016-01-01

    The displaced extra-articular avulsion fracture of the calcaneus has been classified as a Böhler type 1c calcaneal fracture, and most cases will require surgical repair. In the present report, we describe 2 patients in whom we performed the soft anchor bridge technique using single loaded suture anchors with lag screws for the repair of Böhler type 1c avulsion fractures of the calcaneus. In one of these patients, clinically relevant osteoporosis complicated the injury. In both cases, bone union was achieved, and by 1.5 months after surgery satisfactory recovery was observed. To our knowledge, the soft anchor bridge technique was first used for the treatment of rotator cuff tears, and the greatest merit of this technique is the ability to generate vertical compression force to the pulled out rotator cuff through the use of knotting sutures. In recent years, the soft anchor bridge technique using 4 suture anchors has also been used for fractures of the greater tuberosity of the humerus, an injury that poses operative difficulties similar to those encountered with an avulsion fracture of the calcaneus owing to the traction force of the rotator cuff and relative weakness of adjacent bone. The outcomes of our patients suggest that the soft anchor bridge technique combined with adjunct lag screws is useful in the fixation of avulsion fractures of the calcaneus. In addition, the result in the elderly patient indicates the possibility of using this technique for patients with osteoporosis. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Osteosynthesis of the first phalanx fractures in horses by means of lag screws; Osteosynteza zlaman kosci pecinowej u koni z zastosowaniem srub ciagnacych

    Energy Technology Data Exchange (ETDEWEB)

    Bereznowski, A.; Janicki, A.M.; Sterna, J. [Katedra Chirurgii Zwierzat, Wydzial Weterynarii, SGGW-AR, Warsaw (Poland)

    1996-12-31

    Fractures of the first phalanx belong to the most frequent in horses. Three cases of surgical treatment of first phalanx fractures in horses have been presented. The cases differed by the period of time between the accident and surgical treatment. In all cases osteosynthesis by means of orthopedic screws was applied. In all horses fracture repair was successful, however, not all horses recovered fully enough to return to work. (author). 6 refs, 5 figs.

  9. [Clinical application of atlas translaminar screws fixation in treatment of atlatoaxial instability].

    Science.gov (United States)

    Wang, Guoyou; Fu, Shijie; Shen, Huarui; Guan, Taiyuan; Xu, Ping

    2013-10-01

    To explore the effectiveness of fixation of atlas translaminar screws in the treatment of atlatoaxial instability. A retrospective analysis was made on the clinical data of 32 patients with atlatoaxial instability treated with atlantoaxial trans-pedicle screws between March 2007 and August 2009. Of them, 7 patients underwent atlas translaminar screws combined with axis transpedicle screws fixation because of fracture types, anatomic variation, and intraoperative reason, including 5 males and 2 females with an average age of 48.2 years (range, 35-69 years). A total of 9 translaminar screws were inserted. Injury was caused by traffic accident in 4 cases, falling from height in 2 cases, and crushing in 1 case. Two cases had simple odontoid fracture (Anderson type II), and 5 cases had odontoid fracture combined with other injuries (massa lateralis atlantis fracture in 2, atlantoaxial dislocation in 1, and Hangman fracture in 2). The interval between injury and operation was 4-9 days (mean, 6 days). The preoperative Japanese Orthopaedic Association (JOA) score was 8.29 +/- 1.60. The X-ray films showed good position of the screws. Healing of incision by first intention was obtained, and no patient had injuries of the spinal cord injury, nerve root, and vertebral artery. Seven cases were followed up 9-26 months (mean, 14 months). Good bone fusion was observed at 8 months on average (range, 6-11 months). No loosening, displacement, and breakage of internal fixation, re-dislocation and instability of atlantoaxial joint, or penetrating of pedicle screw into the spinal canal and the spinal cord occurred. The JOA score was significantly improved to 15.29 +/- 1.38 at 6 months after operation (t = 32.078, P = 0.000). Atlas translaminar screws fixation has the advantages of firm fixation, simple operating techniques, and relative safety, so it may be a remedial measure of atlatoaxial instability.

  10. The Use of Percutaneous Lumbar Fixation Screws for Bilateral Pedicle Fractures with an Associated Dislocation of a Lumbar Disc Prosthesis

    Directory of Open Access Journals (Sweden)

    William D. Harrison

    2013-01-01

    Full Text Available Study Design. Case report. Objective. To identify a safe technique for salvage surgery following complications of total disc replacement. Summary of Background Data. Lumbar total disc replacement (TDR is considered by some as the gold standard for discogenic back pain. Revision techniques for TDR and their complications are in their infancy. This case describes a successful method of fixation for this complex presentation. Methods and Results. A 48-year-old male with lumbar degenerative disc disease and no comorbidities. Approximately two weeks postoperatively for a TDR, the patient represented with acute severe back pain and the TDR polyethylene inlay was identified as dislocated anteriorly. Subsequent revision surgery failed immediately as the polyethylene inlay redislocated intraoperatively. Further radiology identified bilateral pedicle fractures, previously unseen on the plain films. The salvage fusion of L5/S1 reutilized the anterior approach with an interbody fusion cage and bone graft. The patient was then turned intraoperatively and redraped. The percutaneous pedicle screws were used to fix L5 to the sacral body via the paracoccygeal corridor. Conclusion. The robust locking screw in the percutaneous screw allowed a complete fixation of the pedicle fractures. At 3-year followup, the patient has an excellent result and has returned to playing golf.

  11. Treatment for Trochanteric Fracture of the Femur with Short Femoral Nail: A Comparison between the Asian Intramedullary Hip Screw (IMHS) and the Conventional IMHS.

    Science.gov (United States)

    Kawaji, Hidemi; Uematsu, Takuya; Oba, Ryosuke; Satake, Yoshihiko; Hoshikawa, Naoya; Takai, Shinro

    2016-01-01

    We usually use short femoral nails for the treatment of trochanteric fracture of the femur. In this retrospective study, we investigated and compared the clinical results of the conventional intramedullary hip screw (IMHS) and the Asian IMHS, which is a redesigned version of the former. The subjects were 42 patients; 21 treated with the Asian IMHS and 21 were treated with the conventional IMHS. From the clinical records, we retrospectively investigated the patients' age, sex, in-hospital waiting period for operation, operating time, intraoperative blood loss, walking ability before fracture and at discharge, and complication pertaining to the operation. The 21 patients (4 men and 17 women) receiving the Asian IMHS and the 21 patients (5 men and 16 women) receiving the conventional IMHS did not differ significantly in mean age, sex ratio, preoperative waiting period, mean postoperative hospital stay, mean operation time, or mean intraoperative blood loss. Among patients receiving the Asian IMHS, the complications of intraoperative fractures of the femur developed in 3 patients and breakage of the implant occurred in 1 patient. No complications occurred in patients receiving the conventional IMHS. Compared with the conventional IMHS, the Asian IMHS is smaller, has increased variations in the shaft/neck angle of the lag screw, and has a titanium-alloy construction, allowing magnetic resonance imaging. The intraoperative fracture may have occurred because of the configuration of the distal interlocking screw in the Asian IMHS. Breakage of the implant likely occurred because the nail was too small in diameter, and too short in length for the unstable AO 31-A3 fracture. If careful attention is paid to the configuration of its distal interlocking screw intraoperatively and a nail of appropriate size is selected, the Asian IMHS is better suited than the conventional IMHS for treating Japanese patients, who generally have a small physique, because of its many variations in

  12. Complications associated with distraction plate fixation of wrist fractures.

    Science.gov (United States)

    Hanel, Douglas P; Ruhlman, Scott David; Katolik, Leo I; Allan, Christopher H

    2010-05-01

    This article discusses the major and minor complications of distal plating in the light of a cohort study carried out by the authors, who reviewed all patients undergoing bridge distraction plate fixation of distal radius fractures by three surgeons in a single level I trauma center. The article discusses the effectiveness and the complication rates associated with the technique. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  13. Adult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures.

    Science.gov (United States)

    Sanders, Samuel; Egol, Kenneth A

    2009-01-01

    Two cases are presented in which adult, precontoured, lower-extremity periarticular locking plates were utilized for fixation of subtrochanteric femur fractures in pediatric patients. Recognition of the fact that a distal tibial locking plate in a small child and a proximal tibial locking plate in an adolescent anatomically ft the proximal femur in each case may provide a surgeon treating subtrochanteric hip fractures in this population increased options for operative stabilization.

  14. [Contact characteristics research of acetabular weight-bearing area with different internal fixation methods after compression fracture of acetabular dome].

    Science.gov (United States)

    Xu, Bowen; Zhang, Qingsong; An, Siqi; Pei, Baorui; Wu, Xiaobo

    2017-08-01

    To establish the model of compression fracture of acetabular dome, and to measure the contact characteristics of acetabular weight-bearing area of acetabulum after 3 kinds of internal fixation. Sixteen fresh adult half pelvis specimens were randomly divided into 4 groups, 4 specimens each group. Group D was the complete acetabulum (control group), and the remaining 3 groups were prepared acetabular dome compression fracture model. The fractures were fixed with reconstruction plate in group A, antegrade raft screws in group B, and retrograde raft screws in group C. The pressure sensitive films were attached to the femoral head, and the axial compression test was carried out on the inverted single leg standing position. The weight-bearing area, average stress, and peak stress were measured in each group. Under the loading of 500 N, the acetabular weight-bearing area was significantly higher in group D than in other 3 groups ( P area were significantly higher in group B and group C than in group A, and the average stress and peak stress were significantly lower than in group A ( P 0.05). For the compression fracture of the acetabular dome, the contact characteristics of the weight-bearing area can not restore to the normal level, even if the anatomical reduction and rigid internal fixation were performed; compared with the reconstruction plate fixation, antegrade and retrograde raft screws fixations can increase the weight-bearing area, reduce the average stress and peak stress, and reduce the incidence of traumatic arthritis.

  15. Minimally invasive plate osteosynthesis of humeral shaft fractures: a technique to aid fracture reduction and minimize complications.

    Science.gov (United States)

    Shin, Sang-Jin; Sohn, Hoon-Sang; Do, Nam-Hoon

    2012-10-01

    To introduce a modified operative technique for minimally invasive plate osteosynthesis (MIPO) for acute displaced humeral shaft fractures and to evaluate the clinical and radiological outcomes. : Prospective clinical series study. University hospital. Twenty-one patients with acute displaced humeral shaft fractures were treated by MIPO with a modified fracture reduction technique. A narrow 4.5/5.0-mm locking compression plate was applied to the anterior aspect of the humerus. Fracture reduction and manipulation were performed using a plate and drill bits. The operating time, time to union, humeral alignment, and functional outcome of the shoulder and elbow joints were evaluated using the University of California Los Angeles shoulder score and Mayo elbow performance score. No patient experienced a neurological complication. Bony union was obtained in 20/21 patients at a mean 17.5 weeks postoperatively. Eighteen patients had excellent and 3 patients had good results in the University of California Los Angeles score. The average Mayo elbow performance score was 97.5. Two patients were converted to an open reduction during operation due to a failure of MIPO. There was 1 nonunion and 1 malunion in this series. Although the MIPO technique for humeral shaft fractures is technically demanding, satisfactory clinical outcomes in terms of bony union and shoulder and elbow function can be obtained using the modified fracture reduction method. Potential postoperative complications, such as malreduction and nonunion, must be considered. Appropriate surgical indications, a thorough understanding of the neurovascular anatomy and skillful surgical technique, are needed to reduce potential complications.

  16. On low temperature glide of dissociated 〈1 1 0〉 dislocations in strontium titanate

    Science.gov (United States)

    Ritterbex, Sebastian; Hirel, Pierre; Carrez, Philippe

    2018-05-01

    An elastic interaction model is presented to quantify low temperature plasticity of SrTiO3 via glide of dissociated 〈1 1 0〉{1 1 0} screw dislocations. Because 〈1 1 0〉 dislocations are dissociated, their glide, controlled by the kink-pair mechanism at T good quantitative agreement with the observed non-monotonic mechanical behaviour of SrTiO3. This agreement allows to explain the experimental results in terms of a (progressive) change in 〈1 1 0〉{1 1 0} glide mechanism, from simultaneous nucleation of two kink-pairs along both partials at low stress, towards nucleation of single kink-pairs on individual partials if resolved shear stress exceeds a critical value of 95 MPa. High resolved shear stress allows thus for the activation of extra nucleation mechanisms on dissociated dislocations impossible to occur under the sole action of thermal activation. We suggest that stress condition in conjunction with core dissociation is key to the origin of non-monotonic plastic behaviour of SrTiO3 at low temperatures.

  17. Two peg spade plate for distal radius fractures A novel technique

    Directory of Open Access Journals (Sweden)

    Sharad M Hardikar

    2015-01-01

    Conclusions: The two peg volar spade plate provides a stable subchondral support in comminuted intraarticular fractures and maintains reduction in osteoporotic fractures of the distal radius. Early mobilization with this implant helps in restoring wrist motion and to prevent development of wrist stiffness.

  18. Finite element analysis of functionally graded bone plate at femur bone fracture site

    Science.gov (United States)

    Satapathy, Pravat Kumar; Sahoo, Bamadev; Panda, L. N.; Das, S.

    2018-03-01

    This paper focuses on the analysis of fractured Femur bone with functionally graded bone plate. The Femur bone is modeled by using the data from the CT (Computerized Tomography) scan and the material properties are assigned using Mimics software. The fracture fixation plate used here is composed of Functionally Graded Material (FGM). The functionally graded bone plate is considered to be composed of different layers of homogeneous materials. Finite element method approach is adopted for analysis. The volume fraction of the material is calculated by considering its variation along the thickness direction (z) according to a power law and the effective properties of the homogeneous layers are estimated. The model developed is validated by comparing numerical results available in the literature. Static analysis has been performed for the bone plate system by considering both axial compressive load and torsional load. The investigation shows that by introducing FG bone plate instead of titanium, the stress at the fracture site increases by 63 percentage and the deformation decreases by 15 percentage, especially when torsional load is taken into consideration. The present model yields better results in comparison with the commercially available bone plates.

  19. Analysis of Plasticity, Fracture and Friction in Steady State Plate Cutting

    DEFF Research Database (Denmark)

    Simonsen, Bo Cerup; Wierzbicki, Tomasz

    1996-01-01

    perpendicular to the direction of motion is derived theoretically in a new consistent manner. The perpendicular reaction force is of paramount importance for predicting the structural damage of a ship hull because it governs the vertical ship motion and rock penetration which is strongly coupled...... extension of the presented plate model to include more structural members as for example the stiffeners attached to a ship bottom plating. The fracture process is discussed and the model is formulated partly on the basis of the material fracture toughness. The effect of friction and the reaction force...

  20. [A clinical study on the relationship of the tail femur distance and the lag screw migration or cutting-out after the third generation of Gamma nail fixation of intertrochanteric fracture].

    Science.gov (United States)

    Hou, Yu; Yao, Qi; Zhang, Gen'ai; Ding, Lixiang

    2018-01-01

    To confirm the association between tail femur distance (TFD) and lag screw migration or cutting-out in the treatment of intertrochanteric fracture with the third generation of Gamma nail (TGN). The clinical data of 124 cases of intertrochanteric fracture treated with TGN internal fixation and followed up more than 18 months between January 2012 and December 2015 were reviewed and analyzed. There were 52 males and 72 females, with an age of 46-93 years (mean, 78.5 years). According to AO/Association for the Study of Internal Fixation (AO/ASIF) classification, 43 cases were type 31-A1, 69 cases were type 31-A2, and 12 cases were type 31-A3. The time from injury to operation was 1-10 days (mean, 2.9 days). According to the fracture healing of the patients, the patients were divided into the healing group and failure group. The age, gender, height, bone mineral density (BMD), fracture AO/ASIF classification, the time from injury to operation, and the TFD value at 1 day after operation were recorded and compared. The risk factors for the migration or cutting-out of lag screw were analyzed by logistic regression. There were 111 cases in healing group, the healing time was 80-110 days (mean, 95.5 days). There were 13 cases in failure group, including 2 cases of lag screw cutting-out and 11 cases of significant migration. Except for the TFD value at 1 day after operation in failure group was significantly higher than that in the healing group( t =5.14, P =0.00), there was no significant difference in gender, age, height, BMD, fracture of AO/ASIF classification, and the time from injury to operation ( P >0.05) between 2 groups. logistic regression analysis showed that TFD value was a risk factor for the migration or cutting-out of lag screw (B=1.22, standardized coefficient=0.32, Wald χ 2 =14.66, P =0.00, OR=3.37). The patients with higher TFD value had higher risk of postoperative lag screw migration or cutting-out. This result indicates that the appropriate length of the

  1. Percutaneous cannulated screw fixation of sacral fractures and sacroiliac joint disruptions with CT-controlled guidewires performed by interventionalists: Single center experience in treating posterior pelvic instability

    International Nuclear Information System (INIS)

    Fischer, Sebastian; Vogl, Thomas J.; Marzi, Ingo; Zangos, Stephan; Wichmann, Julian L.; Scholtz, Jan-Erik; Mack, Martin G.; Schmidt, Sven; Eichler, Katrin

    2015-01-01

    Highlights: • Minimally invasive sacroiliac screw fixation can be performed under CT-imaging. • Guidewires help in precise placement of cannulated sacroiliac screw. • Only a diminishing rate of misplacements can be seen. • The method appears to be a safe and very accurate procedure. - Abstract: Objective: The purpose of our study was to evaluate minimally invasive sacroiliac screw fixation for treatment of posterior pelvic instability with the help of CT controlled guidewires, assess its accuracy, safety and effectiveness, and discuss potential pitfalls. Methods: 100 guidewires and hollow titan screws were inserted in 38 patients (49.6 ± 19.5 years) suffering from 35 sacral fractures and/or 16 sacroiliac joint disruptions due to 33 (poly-)traumatic, 2 osteoporotic and 1 post-infectious conditions. The guidewire and screw positions were analyzed in multiplanar reconstructions. Results: The mean minimal distance between guidewire and adjacent neural foramina was 4.5 ± 2.01 mm, with a distinctly higher precision in S1 than S2. Eight guidewires showed cortical contacts, resulting in a total of 2% mismatched screws with subsequent wall violation. The fracture gaps were reduced from 3.6 ± 0.53 mm to 1.2 ± 0.54 mm. During follow-up 3 cases of minor iatrogenic sacral impaction (<5 mm) due to the bolting and 2 cases of screw loosening were observed. Interventional time was 84.0 min with a mean of 2.63 screws per patient whilst acquiring a mean of 93.7 interventional CT-images (DLP 336.7 mGy cm). Conclusions: The treatment of posterior pelvic instability with a guidewire-based screw insertion technique under CT-imaging results in a very high accuracy and efficacy with a low complication rate. Careful attention should be drawn to radiation levels

  2. Percutaneous cannulated screw fixation of sacral fractures and sacroiliac joint disruptions with CT-controlled guidewires performed by interventionalists: Single center experience in treating posterior pelvic instability

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Sebastian, E-mail: sebastian.fischer@kgu.de [Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Vogl, Thomas J. [Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Marzi, Ingo [Department of Trauma, Hand and Reconstructive Surgery, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Zangos, Stephan; Wichmann, Julian L.; Scholtz, Jan-Erik; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Schmidt, Sven [Orthopaedic University Hospital Friedrichsheim, Marienburgstraße, 260528 Frankfurt (Germany); Eichler, Katrin [Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany)

    2015-02-15

    Highlights: • Minimally invasive sacroiliac screw fixation can be performed under CT-imaging. • Guidewires help in precise placement of cannulated sacroiliac screw. • Only a diminishing rate of misplacements can be seen. • The method appears to be a safe and very accurate procedure. - Abstract: Objective: The purpose of our study was to evaluate minimally invasive sacroiliac screw fixation for treatment of posterior pelvic instability with the help of CT controlled guidewires, assess its accuracy, safety and effectiveness, and discuss potential pitfalls. Methods: 100 guidewires and hollow titan screws were inserted in 38 patients (49.6 ± 19.5 years) suffering from 35 sacral fractures and/or 16 sacroiliac joint disruptions due to 33 (poly-)traumatic, 2 osteoporotic and 1 post-infectious conditions. The guidewire and screw positions were analyzed in multiplanar reconstructions. Results: The mean minimal distance between guidewire and adjacent neural foramina was 4.5 ± 2.01 mm, with a distinctly higher precision in S1 than S2. Eight guidewires showed cortical contacts, resulting in a total of 2% mismatched screws with subsequent wall violation. The fracture gaps were reduced from 3.6 ± 0.53 mm to 1.2 ± 0.54 mm. During follow-up 3 cases of minor iatrogenic sacral impaction (<5 mm) due to the bolting and 2 cases of screw loosening were observed. Interventional time was 84.0 min with a mean of 2.63 screws per patient whilst acquiring a mean of 93.7 interventional CT-images (DLP 336.7 mGy cm). Conclusions: The treatment of posterior pelvic instability with a guidewire-based screw insertion technique under CT-imaging results in a very high accuracy and efficacy with a low complication rate. Careful attention should be drawn to radiation levels.

  3. Percutaneous internal fixation of proximal fifth metatarsal jones fractures (Zones II and III) with Charlotte Carolina screw and bone marrow aspirate concentrate: an outcome study in athletes.

    Science.gov (United States)

    Murawski, Christopher D; Kennedy, John G

    2011-06-01

    Internal fixation is a popular first-line treatment method for proximal fifth metatarsal Jones fractures in athletes; however, nonunions and screw breakage can occur, in part because of nonspecific fixation hardware and poor blood supply. To report the results from 26 patients who underwent percutaneous internal fixation with a specialized screw system of a proximal fifth metatarsal Jones fracture (zones II and III) and bone marrow aspirate concentrate. Case series; Level of evidence, 4. Percutaneous internal fixation for a proximal fifth metatarsal Jones fracture (zones II and III) was performed on 26 athletic patients (mean age, 27.47 years; range, 18-47). All patients were competing at some level of sport and were assessed preoperatively and postoperatively using the Foot and Ankle Outcome Score and SF-12 outcome scores. The mean follow-up time was 20.62 months (range, 12-28). Of the 26 fractures, 17 were traditional zone II Jones fractures, and the remaining 9 were zone III proximal diaphyseal fractures. The mean Foot and Ankle Outcome Score significantly increased, from 51.15 points preoperatively (range, 14-69) to 90.91 at final follow-up (range, 71-100; P fracture healing on standard radiographs was 5 weeks after surgery (range, 4-24). Two patients did not return to their previous levels of sporting activity. One patient experienced a delayed union, and 1 healed but later refractured. Percutaneous internal fixation of proximal fifth metatarsal Jones fractures, with a Charlotte Carolina screw and bone marrow aspirate concentrate, provides more predictable results while permitting athletes a return to sport at their previous levels of competition, with few complications.

  4. Minimally invasive plate osteosynthesis for humerus diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    M Shantharam Shetty

    2011-01-01

    Full Text Available Background: Minimally invasive plate osteosynthesis (MIPO technique is reported as a satisfactory procedure for the treatment of humeral shaft fractures by the anterior approach by several authors. However, none of the published reports had a significant follow-up nor have they reported patient outcomes. We evaluated the clinical, radiographic, and functional outcome over a minimum follow-up of 2 years using the same MIPO technique to humeral shaft fracture. Materials and Methods: 32 adult patients with diaphyseal fractures of the humerus treated with MIPO between June 2007 and October 2008 were included in the study. Patients with metabolic bone disease, polytrauma, and Gustilo and Anderson type 3 open fractures with injury severity score >16 were excluded from the study. All cases were treated with closed indirect reduction and locking plate fixation using the MIPO technique. The surgery time, radiation exposure, and time for union was noted. The shoulder and elbow function was assessed using the UCLA shoulder and Mayo elbow performance scores, respectively. Results: Of the 32 patients in the study, 19 were males and 13 were females. The mean age was 39 years (range: 22-70 years. Twenty-seven of the thirty-two patients (84.3% had the dominant side fractured. We had eight cases of C2 type; five cases of C1 and A2 type; four cases of B2 type; three cases each of B3, B1, and A1 type; and one case of A3 type of fracture. The mean surgical time was 91.5 minutes (range: 70-120 minutes and mean radiation exposure was 160.3 seconds (range: 100-220 seconds. The mean radiological fracture union time was 12.9 weeks (range: 10-20 weeks. Shoulder function was excellent in 27 cases (84.3% and good in remaining 5 cases (15.6% on the UCLA score. Elbow function was excellent in 26 cases (81.2%, good in 5 cases (15.6%, and fair in 1 case (3.1% who had an associated olecranon fracture that was fixed by tension band wire in the same sitting. Conclusion: MIPO of

  5. Biomechanical analysis of acromioclavicular joint dislocation treated with clavicle hook plates in different lengths.

    Science.gov (United States)

    Shih, Cheng-Min; Huang, Kui-Chou; Pan, Chien-Chou; Lee, Cheng-Hung; Su, Kuo-Chih

    2015-11-01

    Clavicle hook plates are frequently used in clinical orthopaedics to treat acromioclavicular joint dislocation. However, patients often exhibit acromion osteolysis and per-implant fracture after undergoing hook plate fixation. With the intent of avoiding future complications or fixation failure after clavicle hook plate fixation, we used finite element analysis (FEA) to investigate the biomechanics of clavicle hook plates of different materials and sizes when used in treating acromioclavicular joint dislocation. Using finite element analysis, this study constructed a model comprising four parts: clavicle, acromion, clavicle hook plate and screws, and used the model to simulate implanting different types of clavicle hook plates in patients with acromioclavicular joint dislocation. Then, the biomechanics of stainless steel and titanium alloy clavicle hook plates containing either six or eight screw holes were investigated. The results indicated that using a longer clavicle hook plate decreased the stress value in the clavicle, and mitigated the force that clavicle hook plates exert on the acromion. Using a clavicle hook plate material characterized by a smaller Young's modulus caused a slight increase in the stress on the clavicle. However, the external force the material imposed on the acromion was less than the force exerted on the clavicle. The findings of this study can serve as a reference to help orthopaedic surgeons select clavicle hook plates.

  6. MINIMUM INCISION PERCUTANEOUS PLATE OSTEOSYNTHESIS FOR DISTAL FIBULAR FRACTURES: A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Ramkumar Reddy

    2015-09-01

    Full Text Available Distal fibular fractures are usually communitted and most of the times osteoporotic especially if they are occurring in females and in geriatric age group. These fractures are usu ally associated with other fractures, which necessitates them to be fixed accurately. Owing to the fact that distal fragment is subcutaneous with scanty soft tissue over bone, which pose these fracture fixations become difficult by open methods in view of wound healing. A prospective study of 26 patients with distal fibular fractures were treated with MIPPO with hook plate were healed with less complications and better outcome. With this background we suggest a minimally invasive incision over proximal frag ment where sufficient soft tissue cover is present. From there pushing the special hook plate subperiosteally to distal fragment, hooking the tip of fibula and fixing the proximal fragment after reduction gives a simple and effective stable fixation

  7. Costs Associated With Single-Use and Conventional Sets for Distal Radius Plating.

    Science.gov (United States)

    Fugarino, Bryce; Fox, Mary Patricia; Terhoeve, Cristina; Pappas, Nicholas

    2017-11-01

    Volar plating of distal radius fractures is an increasingly common procedure. Presterilized, single-use volar plate fixation sets have been purported to increase operating room efficiency and decrease cost. The purpose of this study was to compare the actual cost of using a conventional set compared with the projected cost of using its single-use counterpart. We retrospectively analyzed 30 consecutive cases of volar plate fixation in which conventional instrument sets were used. Hardware and processing costs were calculated for the conventional sets and compared with the projected cost of using single-use sets. The mean total cost of hardware and processing for the conventional sets was $2,728, whereas the projected cost for the single-use sets was slightly higher at $2,868. Twenty-three of the 30 cases would have required additional screws not available in the single-use set. The cost of the additional screws needed to supplement the single-use set would have added an average of $282/case. Overall, the combined hardware and processing cost was lower for conventional sets in 25 of the 30 cases. Although the price of the single-use set is less than the mean charge for use of a conventional set, additional screws not available in the single-use set were required in 77% of cases and consequently rendered the conventional set cheaper in 83% of cases. Stocking the single-use sets with additional screws to reflect the most commonly used screw lengths could make these sets more cost effective in the future. Economic and decision analysis IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. Biopolymer augmentation of the lag screw in the treatment of femoral neck fractures - a biomechanical in-vitro study

    Directory of Open Access Journals (Sweden)

    Paech A

    2010-04-01

    Full Text Available Abstract The cut-out of the sliding screw is one of the most common complications in the treatment of intertrochanteric fractures. The reasons for the cut-out are: a suboptimal position of the hip-screw in the femoral head, the type of fracture and poor bone quality. The aim of this study was to reproduce the cut-out event biomechanically and to evaluate the possible prevention of this event by the use of a biopolymer augmentation of the hip screw. Concerning the density and compression force of osteoporotic femoral bone polyurethane foam according to the terms of the Association for Standard Testing Material (ASTMF 1839-97 was used as test material. The polyurethane foam Lumoltan 200 with a compression force of 3.3 Mpa and a density of 0.192 g/cm3 was used to reproduce the osteoporotic bone of the femoral fragment (density 12 lbm/ft3. A cylinder of 50 mm of length and 50 mm of width was produced by a rotary splint raising procedure with planar contact. The axial load of the system was performed by a hydraulic force cylinder of a universal test machine type Zwick 1455, Ulm, Germany. The CCD-angle of the used TGN-System was preset at 130 degrees. The migration pattern of the hip screw in the polyurethane foam was measured and expressed as a curve of the distance in millimeter [mm] against the applied load in Newton [N] up to the cut-out point. During the tests the implants reached a critical changing point from stable to unstable with an increased load progression of steps of 50 Newton. This unstable point was characterized by an increased migration speed in millimeters and higher descending gradient in the migration curve. This peak of the migration curve served as an indicator for the change of the hip screw position in the simulated bone material. The applied load in the non-augmented implant showed that in this group for a density degree of 12 (0,192 g/cm3 the mean force at the failure point was 1431 Newton (± 52 Newton. In the augmented

  9. Percutaneous cannulated screw fixation of sacral fractures and sacroiliac joint disruptions with CT-controlled guidewires performed by interventionalists: single center experience in treating posterior pelvic instability.

    Science.gov (United States)

    Fischer, Sebastian; Vogl, Thomas J; Marzi, Ingo; Zangos, Stephan; Wichmann, Julian L; Scholtz, Jan-Erik; Mack, Martin G; Schmidt, Sven; Eichler, Katrin

    2015-02-01

    The purpose of our study was to evaluate minimally invasive sacroiliac screw fixation for treatment of posterior pelvic instability with the help of CT controlled guidewires, assess its accuracy, safety and effectiveness, and discuss potential pitfalls. 100 guidewires and hollow titan screws were inserted in 38 patients (49.6±19.5 years) suffering from 35 sacral fractures and/or 16 sacroiliac joint disruptions due to 33 (poly-)traumatic, 2 osteoporotic and 1 post-infectious conditions. The guidewire and screw positions were analyzed in multiplanar reconstructions. The mean minimal distance between guidewire and adjacent neural foramina was 4.5±2.01mm, with a distinctly higher precision in S1 than S2. Eight guidewires showed cortical contacts, resulting in a total of 2% mismatched screws with subsequent wall violation. The fracture gaps were reduced from 3.6±0.53mm to 1.2±0.54mm. During follow-up 3 cases of minor iatrogenic sacral impaction (<5mm) due to the bolting and 2 cases of screw loosening were observed. Interventional time was 84.0min with a mean of 2.63 screws per patient whilst acquiring a mean of 93.7 interventional CT-images (DLP 336.7mGycm). The treatment of posterior pelvic instability with a guidewire-based screw insertion technique under CT-imaging results in a very high accuracy and efficacy with a low complication rate. Careful attention should be drawn to radiation levels. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Simple Technique for Removing Broken Pedicular Screws

    Directory of Open Access Journals (Sweden)

    A Agrawal

    2014-03-01

    Full Text Available The procedure for removing a broken pedicle screw should ideally be technically easy and minimally invasive, as any damage to the pedicle, during removal of the broken screw, may weaken the pedicle, thus compromising on the success of re-instrumentation. We describe the case of a 32-year old man who had undergone surgery for traumatic third lumbar vertebral body fracture three years prior to current admission and had developed the complication of pedicle screw breakage within the vertebral body. The patient underwent re-exploration and removal of the distal screws. Through a paravertebral incision and muscle separation, the screws and rods were exposed and the implants were removed.

  11. Fixation of fractures of the condylar head of the mandible with a new magnesium-alloy biodegradable cannulated headless bone screw.

    Science.gov (United States)

    Leonhardt, H; Franke, A; McLeod, N M H; Lauer, G; Nowak, A

    2017-07-01

    It is difficult to fix fractures of the condylar head of the mandible. Several techniques have been described which show satisfactory outcomes, but stability can be questionable, and some can cause irritation of the soft tissues. We describe a technique and first results of treating such fractures with resorbable magnesium-based headless bone screws (Magnezix ® 2.7mm CS; Syntellix AG, Hanover, Germany). Copyright © 2017 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Inspection and replacement of baffle assembly screws inside American reactor vessels

    International Nuclear Information System (INIS)

    Neal, K.; Chaumont, J.C.

    1999-01-01

    The baffle assembly inside the vessel of a 900 MWe reactor designed by Framatome, is made up of 44 plates fixed on 8 horizontal supports by a system of about 1000 screws. These plates undergo high neutron flux and the problem of screw cracking appeared at the end of the eighties in the first-generation reactors. The first operation on a large scale concerning the screws of a Westinghouse type reactor, was performed on the Tihange-1 power plant where Framatome controlled 960 screws and replaced 91. In 1997 as a consequence of the Belgian and French feedback experience, American plant operators launched a vast program of preventive actions: material analysis, inspection of baffle plate screws and replacement of defective screws. This program was held in cooperation with EPRI (electric power research institute) and under the control of NRC (nuclear regulatory commission). Framatome Technologies Inc (FTI) was in charge of the in-situ inspection and replacement of the screws. FTI designed special tools and equipment adapted to the 2-loop American reactors but the basis ideas were those applied on the Tihange reactor. The successful experience of FTI has allowed the firm to be commissioned for 6 2-loops American reactors. (A.C.)

  13. Influence of screw holes and gamma sterilization on properties of phosphate glass fiber-reinforced composite bone plates.

    Science.gov (United States)

    Han, Na; Ahmed, Ifty; Parsons, Andrew J; Harper, Lee; Scotchford, Colin A; Scammell, Brigitte E; Rudd, Chris D

    2013-05-01

    Polymers prepared from polylactic acid (PLA) have found a multitude of uses as medical devices. For a material that degrades, the main advantage is that an implant would not necessitate a second surgical event for removal. In this study, fibers produced from a quaternary phosphate-based glass (PBG) in the system 50P2O5-40CaO-5Na2O-5Fe2O3 were used to reinforce PLA polymer. The purpose of this study was to assess the effect of screw holes in a range of PBG-reinforced PLA composites with varying fiber layup and volume fraction. The flexural properties obtained showed that the strength and modulus values increased with increasing fiber volume fraction; from 96 MPa to 320 MPa for strength and between 4 GPa and 24 GPa for modulus. Furthermore, utilizing a larger number of thinner unidirectional (UD) fiber prepreg layers provided a significant increase in mechanical properties, which was attributed to enhanced wet out and thus better fiber dispersion during production. The effect of gamma sterilization via flexural tests showed no statistically significant difference between the sterilized and nonsterilized samples, with the exception of the modulus values for samples with screw holes. Degradation profiles revealed that samples with screw holes degraded faster than those without screw holes due to an increased surface area for the plates with screw holes in PBS up to 30 days. Scanning electron microscope (SEM) analysis revealed fiber pullout before and after degradation. Compared with various fiber impregnation samples, with 25% volume fraction, 8 thinner unidirectional prepreg stacked samples had the shortest fiber pull-out lengths in comparison to the other samples investigated.

  14. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  15. Experimental Fracture Model versus Osteotomy Model in Metacarpal Bone Plate Fixation

    Directory of Open Access Journals (Sweden)

    S. Ochman

    2011-01-01

    Full Text Available Introduction. Osteotomy or fracture models can be used to evaluate mechanical properties of fixation techniques of the hand skeleton in vitro. Although many studies make use of osteotomy models, fracture models simulate the clinical situation more realistically. This study investigates monocortical and bicortical plate fixation on metacarpal bones considering both aforementioned models to decide which method is best suited to test fixation techniques. Methods. Porcine metacarpal bones (=40 were randomized into 4 groups. In groups I and II bones were fractured with a modified 3-point bending test. The intact bones represented a further control group to which the other groups after fixation were compared. In groups III and IV a standard osteotomy was carried out. Bones were fixated with plates monocortically (group I, III and bicortically (group II, IV and tested for failure. Results. Bones fractured at a mean maximum load of 482.8 N ± 104.8 N with a relative standard deviation (RSD of 21.7%, mean stiffness was 122.3 ± 35 N/mm. In the fracture model, there was a significant difference (=0.01 for maximum load of monocortically and bicortically fixed bones in contrast to the osteotomy model (=0.9. Discussion. In the fracture model, because one can use the same bone for both measurements in the intact state and the bone-plate construct states, the impact of inter-individual differences is reduced. In contrast to the osteotomy model there are differences between monocortical and bicortical fixations in the fracture model. Thus simulation of the in vivo situation is better and seems to be suitable for the evaluation of mechanical properties of fixation techniques on metacarpals.

  16. Radiographic Outcomes of Dorsal Distraction Distal Radius Plating for Fractures With Dorsal Marginal Impaction.

    Science.gov (United States)

    Huish, Eric G; Coury, John G; Ibrahim, Mohamed A; Trzeciak, Marc A

    2017-04-01

    The purpose of this study is to compare radiographic outcomes of patients treated with dorsal spanning plates with previously reported normal values of radiographic distal radius anatomy and compare the results with prior publications for both external fixation and internal fixation with volar locked plates. Patients with complex distal radius fractures including dorsal marginal impaction pattern necessitating dorsal distraction plating at the discretion of the senior authors (M.A.T. and M.A.I.) from May 30, 2013, to December 29, 2015, were identified and included in the study. Retrospective chart and radiograph review was performed on 19 patients, 11 male and 8 female, with mean age of 47.83 years (22-82). No patients were excluded from the study. All fractures united prior to plate removal. The average time the plate was in place was 80.5 days (49-129). Follow-up radiographs showed average radial inclination of 20.5° (13.2°-25.5°), radial height of 10.7 mm (7.5-14 mm), ulnar variance of -0.3 mm (-2.1 to 3.1 mm), and volar tilt of 7.9° (-3° to 15°). One patient had intra-articular step-off greater than 2 mm. Dorsal distraction plating of complex distal radius fractures yields good radiographic results with minimal complications. In cases of complex distal radius fractures including dorsal marginal impaction where volar plating is not considered adequate, a dorsal distraction plate should be considered as an alternative to external fixation due to reduced risk for infection and better control of volar tilt.

  17. Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN Versus Dynamic Hip Screw(DHS

    Directory of Open Access Journals (Sweden)

    Cyril Jonnes

    2016-01-01

    Full Text Available Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN, in Type II intertrochanteric fractures (Boyd and Griffin classification. This study was done to compare the functional and radiological outcome of PFN with DHS in treatment of Type II intertrochanteric fractures.   Methods: From October 2012 to March 2015, a prospective comparative study was done where 30 alternative cases of type II intertrochanteric fractures of hip were operated using PFN or DHS. Intraoperative complications were noted. Functional outcome was assessed using Harris Hip Score and radiological findings were compared at 3, 6, and 12 months postoperatively. Results: The average age of the patients was 60 years. In our series we found that patients with DHS had increased intraoperative blood loss (159ml, longer duration of surgery (105min, and required longer time for mobilization while patients who underwent PFN had lower intraoperative blood loss (73ml, shorter duration of surgery (91min, and allowed early mobilization. The average limb shortening in DHS group was 9.33 mm as compared with PFN group which was only 4.72 mm. The patients treated with PFN started early ambulation as they had better Harris Hip Score in the early post-op period. At the end of 12th month, there was not much difference in the functional outcome between the two groups. Conclusion: PFN is better than DHS in type II inter-trochanteric fractures in terms of decreased blood loss, reduced duration of surgery, early weight bearing and mobilization, reduced hospital stay, decreased risk of infection and decreased complications.

  18. Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury.

    Science.gov (United States)

    Mohammed, R; Syed, S; Metikala, S; Ali, Sa

    2011-09-01

    With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures.

  19. Treatment of thoracolumbar burst fractures with variable screw placement or Isola instrumentation and arthrodesis: case series and literature review.

    Science.gov (United States)

    Alvine, Gregory F; Swain, James M; Asher, Marc A; Burton, Douglas C

    2004-08-01

    The controversy of burst fracture surgical management is addressed in this retrospective case study and literature review. The series consisted of 40 consecutive patients, index included, with 41 fractures treated with stiff, limited segment transpedicular bone-anchored instrumentation and arthrodesis from 1987 through 1994. No major acute complications such as death, paralysis, or infection occurred. For the 30 fractures with pre- and postoperative computed tomography studies, spinal canal compromise was 61% and 32%, respectively. Neurologic function improved in 7 of 14 patients (50%) and did not worsen in any. The principal problem encountered was screw breakage, which occurred in 16 of the 41 (39%) instrumented fractures. As we have previously reported, transpedicular anterior bone graft augmentation significantly decreased variable screw placement (VSP) implant breakage. However, it did not prevent Isola implant breakage in two-motion segment constructs. Compared with VSP, Isola provided better sagittal plane realignment and constructs that have been found to be significantly stiffer. Unplanned reoperation was necessary in 9 of the 40 patients (23%). At 1- and 2-year follow-up, 95% and 79% of patients were available for study, and a satisfactory outcome was achieved in 84% and 79%, respectively. These satisfaction and reoperation rates are consistent with the literature of the time. Based on these observations and the loads to which implant constructs are exposed following posterior realignment and stabilization of burst fractures, we recommend that three- or four-motion segment constructs, rather than two motion, be used. To save valuable motion segments, planned construct shortening can be used. An alternative is sequential or staged anterior corpectomy and structural grafting.

  20. Locking plate fixation in distal metaphyseal tibial fractures: series of 79 patients

    OpenAIRE

    Gupta, Rakesh K.; Rohilla, Rajesh Kumar; Sangwan, Kapil; Singh, Vijendra; Walia, Saurav

    2009-01-01

    Open reduction and internal fixation in distal tibial fractures jeopardises fracture fragment vascularity and often results in soft tissue complications. Minimally invasive osteosynthesis, if possible, offers the best possible option as it permits adequate fixation in a biological manner. Seventy-nine consecutive adult patients with distal tibial fractures, including one patient with a bilateral fracture of the distal tibia, treated with locking plates, were retrospectively reviewed. The 4.5-...

  1. Removal of internal fixation--the effect on patients' complaints: a study of 66 cases of removal of internal fixation after malleolar fractures

    DEFF Research Database (Denmark)

    Jacobsen, S; Honnens de Lichtenberg, M; Jensen, C M

    1994-01-01

    To estimate the effect of removal of internal fixation after treatment of malleolar fractures on postoperatively presented complaints, we retrospectively evaluated 66 patients by their records and by personal questionnaires. Of all the patients, 89.4% had one or more complaints. These were...... typically soreness over implant and cicatrix, reduced movement of the ankle joint, and strain-related pain. About 75% of these patients reported improvement after removal. The AO mode of fixation, i.e., typically by lateral semitubular plating and transsyndesmotic screw and a medial screw or pins...... period. We conclude that removal of internal fixation after malleolar fractures is indicated when common types of complaints are presented....

  2. Combined anterior C2-C3 fusion and C2 pedicle screw fixation for the treatment of unstable hangman's fracture: a contrast to anterior approach only.

    Science.gov (United States)

    Xie, Ning; Khoo, Larry T; Yuan, Wen; Ye, Xiao-Jian; Chen, De-Yu; Xiao, Jian-Ru; Ni, Bin

    2010-03-15

    A retrospective clinical study was used to evaluate the effect of a new surgical treatment of the hangman's fractures. To determine the treatment efficacy of combined anterior C2-C3 reduction and fusion and posterior compressive C2 pedicle screw fixation for the management of unstable hangman's fractures. The classification of hangman's fractures as proposed by Levine-Edwards was used to classify and guide the treatment of these injuries. Most of these fractures respond to a variety of conservative therapies, but recently, earlier surgery has been increasingly advocated by authors from several countries for the rapid stabilization of these fractures. If surgery is indicated, an anterior approach using a C2-C3 reduction and fusion is preferred usually. Another well-accepted surgical method is the direct transpedicular osteosynthesis by the dorsal approach. However, there was rare report of the combined use of these 2 techniques. A group of 45 surgical patients were all diagnosed with radiograph, magnetic resonance imaging (MRI), and 3D CT scans. Initial and final radiographs were measured for anterior translation and angulation of the C2-C3 complex. Initial external skull traction with extension was used in all patients after admission to reduce the fracture. Then an anterior C2-C3 discectomy followed by an interbody fusion and locking plate fixation was performed. Intraoperative reduction was confirmed by fluoroscopic control. About 29 patients therefore received anterior surgeries only since satisfactory reduction was achieved during the procedure. For the 16 patients who had persistent large residual gaps after the anterior procedure, additional same stage posterior C2 compressive pedicle screws were placed. Clinical and radiologic comparisons were performed in these 2 groups. The follow-up ranged from 24 to 54 months, with an average 33.6 months. There was radiographic evidence of continuity of the fracture and the bone graft seen at 4.7 months on average. Neck

  3. Tests for the dynamic behavior of insulation valve screws

    International Nuclear Information System (INIS)

    Tulke, K.D.; Stoppler, W.; Stern, G.

    1994-01-01

    Thermal tensile tests were performed at a temperature of 270 C, with two new original insulation valve conical screws M30-Tx92,5 mm (material: 21 CrMo V 5 7)and two prestrained ones during the event on 27.12.92. In order to assure the results obtained with regard to the dynamic load on the insulation valve during ''quick opening'', in addition tensile impact tests were performed at 270 C with six original insulation valve conical screws. Impact velocity reached 13,5 m/s at four screws and 6 m/s at two screws. Test conditions regarding collision damping and mass distribution were adapted, by means of parameter studies, to the situation of the insulation valve. During thermal tensile tests, strength and deformation values, such as stress at flow start, tensile strength, fracture prolongation and strain, necking at fracture as well as energy absorption up to maximum force and up to rupture, were determined. During tensile impact tests, deformation values, such as elongation, strain and necking, and energy absorption by the screw, were determined. (orig.) [de

  4. Screw piles for cold climate foundations

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.; Sakr, M. [Almita Manufacturing Ltd., Edmonton, AB (Canada)

    2008-07-01

    Almita Manufacturing is an Alberta-based company that designs and builds screw piles with its own installation teams. It also engineers and supplies piles to numerous other companies and independent installers. The company services industries such as oil and gas; power transmission and distribution; and commercial construction. This presentation discussed the design and technical aspects of screw piles. A screw pile was defined as a steel pipe shaft with a 45 degree cut at the bottom and a formed helical plate welded to the outside of the pipe near the base and at a selected point on the shaft. The pile is screwed into the ground with a planetary drive head of suitable torque rating. The helical plate or helix helps facilitate the installation of the pile and gives the screw pile increased bearing capacity and pull-out resistance over a traditional straight-shaft pile. Screw piles were compared against cast in place concrete piles and steel driven piles. Screw piles were reported to have no tailings; no concrete curing time; no rebar, anchor belts, and no liners; and no dewatering. Screw piles can also be installed in all types of weather. Rhe Cree Burn Camp case study near Fort McMurray, Alberta was also presented. This residential camp and recreation complex consists of pre-fabricated units that make up three storey housing buildings and a single floor multi-use building. The case study provided information on soil; design parameter inputs; load testing program and pile configuration; geotechnical and structural design results; compression load test arrangement; pile test setup; and test results. The presentation also discussed fabrication as well as installation equipment. Various applications were also presented through a series of project pictures. Last, the presentation provided a simple cost analysis. tabs., figs.

  5. Cyclic fatigue resistance of R-Pilot, HyFlex EDM and PathFile nickel-titanium glide path files in artificial canals with double (S-shaped) curvature.

    Science.gov (United States)

    Uslu, G; Özyürek, T; Yılmaz, K; Gündoğar, M

    2018-05-01

    To examine the cyclic fatigue resistances of R-Pilot, HyFlex EDM and PathFile NiTi glide path files in S-shaped artificial canals. Twenty R-Pilot (12.5/.04), 20 HyFlex EDM (10/.05) and 20 PathFile (19/.02) single-file glide path files were included. Sixty files (n: 20/each) were subjected to static cyclic fatigue testing using double-curved canals until fracture occurred (TF). The number of cycles to fracture (NCF) was calculated by multiplying the rpm value by the TF. The length of the fractured fragment (FL) was determined by a digital microcaliper. Six samples of fractured files (n: 2/each) were examined by SEM to determine the fracture mode. The NCF and the FL data were analysed using one-way anova, post hoc Tamhane and Kruskal-Wallis tests using SPPS 21 software. The significance level was set at 5%. In the double-curved canal, all the files fractured first in the apical curvature and then in the coronal curvature. The NCF values revealed that the R-Pilot had the greatest cyclic fatigue resistance, followed by the HyFlex EDM and PathFile in both the apical and coronal curvatures (P < 0.05). R-Pilot NiTi glide path files, used in a reciprocating motion, had the greatest cyclic fatigue resistance amongst the tested NiTi glide path files in an artificial S-shaped canal. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  6. Failure analysis of top nozzle holddown spring screw for nuclear fuel assembly

    International Nuclear Information System (INIS)

    Koh, S. K.; Ryu, C. H.; Na, E. G.; Baek, T. H.; Jeon, K. L.

    2003-01-01

    A failure analysis of holddown spring screw was performed using fracture mechanics approach. The spring screw was designed such that it was capable of sustaining the loads imposed by the initial tensile preload and operational loads. In order to investigate the cause of failure, a stress analysis of the top nozzle spring assembly was done using finite element analysis and a life prediction of the screw was made using a fracture mechanics approach. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Primary water stress corrosion cracking life of the Inconel 600 screw was predicted by using integration of the Scott model and resulted in 1.42 years, which was fairly close to the actual service life of the holddown spring screw

  7. A Case of Acromioclavicular Joint Dislocation Associated with Coracoid Process Fracture.

    Science.gov (United States)

    Nakamura, Yosuke; Gotoh, Masafumi; Mitsui, Yasuhiro; Shirachi, Isao; Yoshikawa, Eiichiro; Uryu, Takuya; Murakami, Hidetaka; Okawa, Takahiro; Higuchi, Fujio; Shiba, Naoto

    2015-01-01

    Rupture of any two or more parts of the superior shoulder suspensory complex (SSSC) including the distal clavicle, acromion, coracoid process, glenoid cavity of the scapula, acromioclavicular ligament, and coracoclavicular ligament is associated with shoulder girdle instability and is an indication for surgery. Here we report a case of acromioclavicular joint dislocation associated with coracoid process fracture. A 48-year-old man sustained a hard blow to the left shoulder from a fall, and simple radiography detected a coracoid process fracture and acromioclavicular joint dislocation. The injury consisted of a rupture of two parts of the SSSC. For the coracoid process fracture, osteosynthesis was performed using hollow cancellous bone screws. For the acromioclavicular joint dislocation, hook plate fixation and the modified Neviaser's procedure were performed. The bone healed well 5 months after surgery, at which time the screws were removed. At 18 months after initial surgery, the coracoid process fracture had healed with a 10% rate of dislocation on radiography, and the patient currently has no problem performing daily activities, no range of motion limitations, and a Japanese Orthopaedic Association scale score of 93.

  8. Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures.

    Science.gov (United States)

    Han, L R; Jin, C X; Yan, J; Han, S Z; He, X B; Yang, X F

    2015-03-31

    This study compared the efficacy between external fixator combined with palmar T-plate internal fixation and simple plate internal fixation for the treatment of comminuted distal radius fractures. A total of 61 patients classified as type C according to the AO/ASIF classification underwent surgery for comminuted distal radius fractures. There were 54 and 7 cases of closed and open fractures, respectively. Moreover, 19 patients received an external fixator combined with T-plate internal fixation, and 42 received simple plate internal fixation. All patients were treated successfully during 12-month postoperative follow-up. The follow-up results show that the palmar flexion and dorsiflexion of the wrist, radial height, and palmar angle were significantly better in those treated with the external fixator combined with T-plate compared to those treated with the simple plate only (P 0.05). Hence, the effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures was satisfactory. Patients sufficiently recovered wrist, forearm, and hand function. In conclusion, compared to the simple T-plate, the external fixator combined with T-plate internal fixation can reduce the possibility of the postoperative re-shifting of broken bones and keep the distraction of fractures to maintain radial height and prevent radial shortening.

  9. Cyclic fatigue resistances of several nickel-titanium glide path rotary and reciprocating instruments at body temperature.

    Science.gov (United States)

    Yılmaz, K; Uslu, G; Gündoğar, M; Özyürek, T; Grande, N M; Plotino, G

    2018-01-31

    To compare the cyclic fatigue resistance of the One G, ProGlider, HyFlex EDM and R-Pilot glide path NiTi files at body temperature. Twenty One G (size 14, .03 taper), 20 ProGlider (size 16, .02 taper), 20 HyFlex EDM (size 10, .05 taper) and 20 R-Pilot (size 12.5, .04 taper) instruments were operated in rotation at 300 rpm (One G, ProGlider and HyFlex) or in reciprocation (R-Pilot) at 35 °C in artificial canals that were manufactured by reproducing the size and taper of the instrument until fracture occurred. The time to fracture was recorded in seconds using a digital chronometer, and the length of the fractured fragments was registered. Mean data were analysed statistically using the Kruskal-Wallis test and post hoc Tukey tests via SPSS 21.0 software. The statistical significance level was set at 5%. The cyclic fatigue resistance of the R-Pilot files was significantly greater than the other instruments, and the One G was significantly lower (P EDM and the ProGlider (P > 0.05). No significant difference (P > 0.05) was evident in the mean length of the fractured fragments of the various instruments. The cyclic fatigue resistance of the R-Pilot reciprocating glide path file was significantly greater than that of the rotary HyFlex EDM, ProGlider and One G glide path files. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  10. [Medial versus lateral plating in distal tibial fractures: a prospective study of 40 fractures].

    Science.gov (United States)

    Encinas-Ullán, C A; Fernandez-Fernandez, R; Rubio-Suárez, J C; Gil-Garay, E

    2013-01-01

    Tibial plafond fractures are one of the most challenging injuries in orthopaedic surgery. Their results could be improved by following the new guidelines for the management, and modern plating techniques. The results and complication rate between anteromedial and anterolateral approach for open reduction and internal fixation of these fractures were compared. A study was conducted on 40 patients treated by open reduction an internal fixation between 2007 and 2008. The surgical approach was selected by the surgeon in charge, depending on fracture pattern and skin situation. Patients were evaluated clinically and radiographically by an independent orthopaedic surgeon, not involved in the surgical procedure, using clinical (American Orthopaedic Foot and Ankle Society score) and radiological criteria at a minimum of two years. The appearance of complications after both approaches was recorded. Forty patients were included. The mean age was 53 years, with 24 males and 16 females. Seventeen of the injuries were of high energy, and there were 8 open fractures (3 of type i, 4 type ii and one type iii), and 12 of the closed injuries were grade ii or iii in the Tscherne classification. Six patients (15%) had associated injuries. At final follow-up there were 33 (82%) excellent or good results. No statistical differences were found between either surgical approach regarding time to bone union, rate of delayed union and infection rate. Three plates of the anteromedial group and none of the anterolateral group needed to be removed. Open reduction and internal fixation of distal tibia fractures produced reliable results, with no statistical differences found between anteromedial and anterolateral surgical approaches. Clinical and radiological results and complication rate were mainly related to the fracture type. Copyright © 2012 SECOT. Published by Elsevier Espana. All rights reserved.

  11. Effect of Glide Path Creating on Cyclic Fatigue Resistance of Reciproc and Reciproc Blue Nickel-titanium Files: A Laboratory Study.

    Science.gov (United States)

    Özyürek, Taha; Uslu, Gülşah; Yılmaz, Koray; Gündoğar, Mustafa

    2018-06-01

    The purpose of this article was to compare the cyclic fatigue resistance of Reciproc and Reciproc Blue files (VDW GmbH, Munich, Germany) that were used to prepare root canals of mandibular molar teeth with or without a glide path. Sixty Reciproc R25 and 60 Reciproc Blue R25 files were used. The Reciproc and Reciproc Blue groups were divided into 3 subgroups (ie, as received condition, used without a glide path, and used with a glide path). All the instruments were rotated in a stainless steel artificial canal with an inner diameter of 1.5 mm, a 60° angle of curvature, and a radius of curvature of 5 mm until fracture occurred. The number of cycle to fracture was calculated, and the length of the fractured segments was measured. The Kruskal-Wallis test was performed to statistically analyze the data using SPSS 21.0 software (IBM Corp, Armonk, NY) at a 5% significance level. The cyclic fatigue resistance of as received condition Reciproc Blue files was found to be higher than as received condition Reciproc files (P  .05). There was no statistically significant difference in the mean length of the fractured fragments of the instruments (P > .05). Within the limitations of this in vitro study, it was concluded that creating a glide path using ProGlider files had no effect on the cyclic fatigue resistance of RPC and RPC Blue files. Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures

    Directory of Open Access Journals (Sweden)

    TONG Da-ke

    2012-02-01

    Full Text Available 【Abstract】Objective: To investigate the efficacy of the locking internal fixator (LIF, which includes the locking compression plate (LCP and the less invasive stable system (LISS, in the proximal and distal tibial fractures. Methods: We did a retrospective study on a total of 98 patients with either proximal or distal tibial fractures from January 2003 to January 2007, who had received the opera- tion with LIF by the minimally invasive plate osteosynthesis (MIPO technique. The data consisted of 43 proximal tibial fractures (type AO41C3 and 55 distal tibial fractures (type AO43C3. Results: No complications were observed in all patients after operation. The mean healing time was 8.4 months (range 5-14 months. Only two cases of delayed union occurred at postoperative 10 months. No infections were reported after the definitive surgery even in the cases of open fractures. All patients reached a full range of motion at postoperative 6 to 9 months and regained the normal functions of knee and ankle joints. Conclusion: Using LIF in MIPO technique is a reliable approach towards the proximal and distal tibial fractures that are not suitable for intramedullary nailing. Key words: Internal fixator; Tibial fractures; Fracture fixation, intramedullary; Bone plates

  13. Gliding arc discharge — Application for adhesion improvement of fibre reinforced polyester composites

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Teodoru, Steluta; Leipold, Frank

    2008-01-01

    production, and surface treatment. However, the application for adhesion improvement of structural materials has been rarely reported. In the present work, glass fibre reinforced polyester plates were treated using atmospheric pressure gliding arcs with high speed air flow for adhesion improvement...

  14. The pediatric mandible: II. Management of traumatic injury or fracture.

    Science.gov (United States)

    Smartt, James M; Low, David W; Bartlett, Scott P

    2005-08-01

    After studying this article, the participant should be able to: 1. Describe the changing epidemiology of mandibular fractures in children and adolescents. 2. Discuss the appropriate use of internal fixation in the treatment of pediatric mandibular fractures. 3. Describe the difficulties posed by the deciduous dentition in the use of interdental wiring. 4. Understand reasons why techniques specific to adult fractures may not be applicable to the growing mandible. 5. Understand the etiology and epidemiology of pediatric mandibular fractures. 6. Understand the reasons for conservative (closed) versus aggressive (open) treatment of mandibular injury. Fractures of the pediatric mandible are complicated by the anatomic complexity of the developing mandible, particularly by the presence of tooth buds and the eruption of deciduous and permanent teeth. Traditional methods of fracture reduction and fixation employed in adults have little applicability in the pediatric population. The authors describe the surgical techniques that have been used at their institution and those that can be used safely in the pediatric setting. In most cases, "conservative" management is the preferred option, especially in the treatment of condylar fractures. In cases requiring surgical intervention, interdental wiring, drop wires in combination with circummandibular wires, and acrylic splints are suited well to specific phases of dental maturation. Open reduction and internal fixation using monocortical screws and microplates or resorbable plates and screws are acceptable techniques in the pediatric patient, but they require special safeguards. Algorithms are presented to simplify management of these complicated injuries.

  15. Anatomical Thin Titanium Mesh Plate Structural Optimization for Zygomatic-Maxillary Complex Fracture under Fatigue Testing

    Directory of Open Access Journals (Sweden)

    Yu-Tzu Wang

    2018-01-01

    Full Text Available This study performs a structural optimization of anatomical thin titanium mesh (ATTM plate and optimal designed ATTM plate fabricated using additive manufacturing (AM to verify its stabilization under fatigue testing. Finite element (FE analysis was used to simulate the structural bending resistance of a regular ATTM plate. The Taguchi method was employed to identify the significance of each design factor in controlling the deflection and determine an optimal combination of designed factors. The optimal designed ATTM plate with patient-matched facial contour was fabricated using AM and applied to a ZMC comminuted fracture to evaluate the resting maxillary micromotion/strain under fatigue testing. The Taguchi analysis found that the ATTM plate required a designed internal hole distance to be 0.9 mm, internal hole diameter to be 1 mm, plate thickness to be 0.8 mm, and plate height to be 10 mm. The designed plate thickness factor primarily dominated the bending resistance up to 78% importance. The averaged micromotion (displacement and strain of the maxillary bone showed that ZMC fracture fixation using the miniplate was significantly higher than those using the AM optimal designed ATTM plate. This study concluded that the optimal designed ATTM plate with enough strength to resist the bending effect can be obtained by combining FE and Taguchi analyses. The optimal designed ATTM plate with patient-matched facial contour fabricated using AM provides superior stabilization for ZMC comminuted fractured bone segments.

  16. Complication with Removal of a Lumbar Spinal Locking Plate

    Directory of Open Access Journals (Sweden)

    Brooke Crawford

    2015-01-01

    Full Text Available Introduction. The use of locking plate technology for anterior lumbar spinal fusion has increased stability of the vertebral fusion mass over traditional nonconstrained screw and plate systems. This case report outlines a complication due to the use of this construct. Case. A patient with a history of L2 corpectomy and anterior spinal fusion presented with discitis at the L4/5 level and underwent an anterior lumbar interbody fusion (ALIF supplemented with a locking plate placed anterolaterally for stability. Fifteen months after the ALIF procedure, he returned with a hardware infection. He underwent debridement of the infection site and removal of hardware. Results. Once hardware was exposed, removal of the locking plate screws was only successful in one out of four screws using a reverse thread screw removal device. Three of the reverse thread screw removal devices broke in attempt to remove the subsequent screws. A metal cutting drill was then used to break hoop stresses associated with the locking device and the plate was removed. Conclusion. Anterior locking plates add significant stability to an anterior spinal fusion mass. However, removal of this hardware can be complicated by the inherent properties of the design with significant risk of major vascular injury.

  17. Finite element analysis of the equivalent stress distribution in Schanz screws during the use of a femoral fracture distractor

    Directory of Open Access Journals (Sweden)

    Vincenzo Giordano

    Full Text Available ABSTRACT To evaluate the mechanical stress and elastic deformation exercised in the thread/shaft transition of Schanz screws in assemblies with different screw anchorage distances in the entrance to the bone cortex, through the distribution and location of tension in the samples. An analysis of 3D finite elements was performed to evaluate the distribution of the equivalent stress (triple stress state in a Schanz screw fixed bicortically and orthogonally to a tubular bone, using two mounting patterns: (1 thread/shaft transition located 20 mm from the anchorage of the Schanz screws in the entrance to the bone cortex and (2 thread/shaft transition located 3 mm from the anchorage of the Schanz screws in entrance to the bone cortex. The simulations were performed maintaining the same direction of loading and the same distance from the force vector in relation to the center of the hypothetical bone. The load applied, its direction, and the distance to the center of the bone were constant during the simulations in order to maintain the moment of flexion equally constant. The present calculations demonstrated linear behavior during the experiment. It was found that the model with a distance of 20 mm between the Schanz screws anchorage in the entrance to the bone cortex and the thread/shaft transition reduces the risk of breakage or fatigue of the material during the application of constant static loads; in this model, the maximum forces observed were higher (350 MPa. The distance between the Schanz screws anchorage at the entrance to the bone cortex and the smooth thread/shaft transition of the screws used in a femoral distractor during acute distraction of a fracture must be farther from the entrance to the bone cortex, allowing greater degree of elastic deformation of the material, lower mechanical stress in the thread/shaft transition, and minimized breakage or fatigue. The suggested distance is 20 mm.

  18. Indirect reduction with a condylar blade plate for osteosynthesis of subtrochanteric femoral fractures.

    Science.gov (United States)

    Siebenrock, K A; Müller, U; Ganz, R

    1998-01-01

    Subtrochanteric fractures frequently occur as high energy trauma usually in younger patients and may lead to severe comminution of the medial cortex. The medial cortex of the proximal femur is exposed to high compressive forces which make fracture stabilization a difficult problem. Bone healing may be seriously compromised due to extensive comminution and fragment devitalization. This requires reduction techniques which do not cause additional damage to the vitality of the bone. With indirect reduction techniques and the use of a condylar blade plate the results have been significantly improved in these fracture types in our department (1). In this report the essential aspects of indirect reduction for subtrochanteric fractures using a condylar blade plate and the treatment results from our department from earlier years (1) and from the last 2 1/2 years will be presented. In the latter period, fifteen patients with a mean age of 49 years (19-87 years) were treated with this method. Fractures resulted from traffic incidents or falls from a great height in 11 cases (73%). Union was achieved in 14 cases (93%) with full weight-bearing after a mean of 3 months (1-4 1/2 months). Malunion was seen in two cases (13%) without the need for further surgery. Non union occurred in one patient (7%) with a III B open injury due to early infection. After repeated debridements, bone grafting and decortication, the fracture was stabilized with a replacement condylar blade plate and healed uneventfully.

  19. Clinical outcomes of three different types of hardware for the treatment of mandibular angle fractures: a comparative retrospective study.

    Science.gov (United States)

    Elsayed, S A; Mohamed, F I; Khalifa, G A

    2015-10-01

    A retrospective study was conducted to compare the clinical outcomes of three different types of hardware that are used in mandibular angle fracture fixation. Thirty patients were selected from the hospital database. The patients were categorized into the following groups: group A, in which a single 2.0-mm locking miniplate was used; group B, in which a single rigid 2.3-mm plate was used; and group C, in which a single lag screw was inserted. All patients were followed for 6 months. With regard to intraoperative variables, significant differences were found among the groups in the duration of surgery and cost. Group C had the shortest surgical time, followed by group A and then group B. Two patients, one in group A and one in group B, suffered an occlusal discrepancy after surgery. Of the group A patients, two exhibited wound dehiscence and one had an infection. One patient in group B had an exposed plate. Sensory nerve involvement was noted in three group C patients and one group B patient. The lag screw was associated with the fewest complications and exhibited all of the advantages of plating systems in the treatment of angle fracture. The lag screw involved the least hardware and a short operating time, however the differences were not significant. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Cement Augmentation in Sacroiliac Screw Fixation Offers Modest Biomechanical Advantages in a Cadaver Model.

    Science.gov (United States)

    Osterhoff, Georg; Dodd, Andrew E; Unno, Florence; Wong, Angus; Amiri, Shahram; Lefaivre, Kelly A; Guy, Pierre

    2016-11-01

    Sacroiliac screw fixation in elderly patients with pelvic fractures is prone to failure owing to impaired bone quality. Cement augmentation has been proposed as a possible solution, because in other anatomic areas this has been shown to reduce screw loosening. However, to our knowledge, this has not been evaluated for sacroiliac screws. We investigated the potential biomechanical benefit of cement augmentation of sacroiliac screw fixation in a cadaver model of osteoporotic bone, specifically with respect to screw loosening, construct survival, and fracture-site motion. Standardized complete sacral ala fractures with intact posterior ligaments in combination with ipsilateral upper and lower pubic rami fractures were created in osteoporotic cadaver pelves and stabilized by three fixation techniques: sacroiliac (n = 5) with sacroiliac screws in S1 and S2, cemented (n = 5) with addition of cement augmentation, and transsacral (n = 5) with a single transsacral screw in S1. A cyclic loading protocol was applied with torque (1.5 Nm) and increasing axial force (250-750 N). Screw loosening, construct survival, and sacral fracture-site motion were measured by optoelectric motion tracking. A sample-size calculation revealed five samples per group to be required to achieve a power of 0.80 to detect 50% reduction in screw loosening. Screw motion in relation to the sacrum during loading with 250 N/1.5 Nm was not different among the three groups (sacroiliac: 1.2 mm, range, 0.6-1.9; cemented: 0.7 mm, range, 0.5-1.3; transsacral: 1.1 mm, range, 0.6-2.3) (p = 0.940). Screw subsidence was less in the cemented group (3.0 mm, range, 1.2-3.7) compared with the sacroiliac (5.7 mm, range, 4.7-10.4) or transsacral group (5.6 mm, range, 3.8-10.5) (p = 0.031). There was no difference with the numbers available in the median number of cycles needed until failure; this was 2921 cycles (range, 2586-5450) in the cemented group, 2570 cycles (range, 2500-5107) for the sacroiliac specimens, and

  1. Biocompatibility of Bespoke 3D-Printed Titanium Alloy Plates for Treating Acetabular Fractures

    Directory of Open Access Journals (Sweden)

    Xuezhi Lin

    2018-01-01

    Full Text Available Treatment of acetabular fractures is challenging, not only because of its complicated anatomy but also because of the lack of fitting plates. Personalized titanium alloy plates can be fabricated by selective laser melting (SLM but the biocompatibility of these three-dimensional printing (3D-printed plates remains unknown. Plates were manufactured by SLM and their cytocompatibility was assessed by observing the metabolism of L929 fibroblasts incubated with culture medium extracts using a CCK-8 assay and their morphology by light microscopy. Allergenicity was tested using a guinea pig maximization test. In addition, acute systemic toxicity of the 3D-printed plates was determined by injecting extracts from the implants into the tail veins of mice. Finally, the histocompatibility of the plates was investigated by implanting them into the dorsal muscles of rabbits. The in vitro results suggested that cytocompatibility of the 3D-printed plates was similar to that of conventional plates. The in vivo data also demonstrated histocompatibility that was comparable between the two manufacturing techniques. In conclusion, both in vivo and in vitro experiments suggested favorable biocompatibility of 3D-printed titanium alloy plates, indicating that it is a promising option for treatment of acetabular fractures.

  2. Stabilization of Olecranon Fractures by Tension Band Wiring or Plate Osteosynthesis: A Retrospective Study of 41 Cases.

    Science.gov (United States)

    Fournet, Alexandre; Boursier, Jean-François; Corbeau, Solène; Decambron, Adeline; Viateau, Véronique; Fayolle, Pascal; Bedu, Anne-Sophie; Leperlier, Dimitri; Manassero, Mathieu

    2018-01-01

     This article aimed to describe olecranon fracture in dogs and cats and their stabilization with tension band wiring or plate osteosynthesis, and to evaluate complications associated with each technique.  Medical records of cats and dogs that had been surgically treated for olecranon fractures with either tension band wiring or plate osteosynthesis were retrospectively reviewed. The surgical technique, complications and long-term outcomes were assessed.  Forty-one olecranon fractures were included. Fractures were articular, comminuted and open in 90, 31 and 27% of cases, respectively. Tension band wiring and plate osteosynthesis were performed in 22 and 19 fractures, respectively. Complications occurred more commonly after tension band wiring (74%) compared with plate osteosynthesis (27%) ( p  = 0.002) and these were probably related to it being used in comminuted fractures ( p  = 0.01) or to errors in technique. Minor complications included Kirschner wires migration ( n  = 5), pain ( n  = 3), osteomyelitis ( n  = 3), skin breakdown ( n  = 3) and seroma ( n  = 1). Implant failure requiring further fixation ( n  = 4) was observed only in the tension band wiring group. Other major complications included skin wound debridement and closure ( n  = 1) and chronic lameness requiring implant removal ( n  = 7). Long-term functional outcomes were excellent regardless of the technique used.  Plate osteosynthesis should be performed for olecranon fracture repair if technically feasible. Schattauer GmbH Stuttgart.

  3. Monoaxial versus polyaxial locking systems: a biomechanical analysis of different locking systems for the fixation of proximal humeral fractures.

    Science.gov (United States)

    Zettl, Ralph; Müller, Thorben; Topp, Tobias; Lewan, Ulrike; Krüger, Antonio; Kühne, Christian; Ruchholtz, Steffen

    2011-08-01

    The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability. On nine pairs of randomised formalin fixed humerus specimens, standardised osteotomies and osteosyntheses with nine monoaxial (group A) und nine polyaxial (group B) plate/screw systems were performed. A material testing machine by Instron (M-10 14961-DE) was used for cyclic stress tests and crash tests until defined breakup criteria as endpoints were reached. After axial cyclic stress 200 times at 90 N, plastic deformation was 1.02 mm in group A and 1.25 mm in group B. After the next cycle using 180 N the additional deformation averaged 0.23 mm in group A and 0.39 mm in group B. The deformation using 450 N was 0.72 mm in group A compared to 0.92 mm in group B. The final full power test resulted in a deformation average of 0.49 mm in group A and 0.63 mm in group B after 2,000 cycles using 450 N. When reaching the breakup criteria the plastic deformation of the NCB plate was 9.04 mm on average. The PHILOS plate was similarly deformed by 9.00 mm. As a result of the crash test, in group A the screws pulled out of the humeral head four times whereas the shaft broke one time and another time the implant was ripped out. The gap was closed four times. In group B, there were three cases of screw cut-through, four shaft fractures/screw avulsions from the shaft and two cases of gap closure. The two systems resist the cyclic duration tests and the increasing force tests in a similar manner. The considerable clinical benefits of the polyaxial system are enhanced by equal biomechanical performance.

  4. [APPLICATION OF COMPRESSION MINI-SCREWS IN TREATMENT OF PATIENTS WITH INJURY OF ELBOW JOINT BONES].

    Science.gov (United States)

    Neverov, V A; Egorov, K S

    2015-01-01

    A case report presents the experience of application of compression pileateless mini-screws (Gerbert's screws) in treatment of intra-articular fractures, which formed the elbow joint (44 cases). There were performed 32 operations concerning fracture of head of radius, 10 operations on the occasion of fractures of distal section of the humerus and 2 operations on the coronoid process. Long-term treatment results were followed-up in 31 patients during more than 6 months. On basis of analysis of treatment results the authors made a conclusion that the application of mini-screws in case of bone fractures, which formed the elbow joint, allowed realization of stable osteosynthesis after anatomic reposition of articular surfaces, obtaining good anatomical and functional result and shortened the terms of patient's treatment.

  5. Management of C2-C3 fracture subluxation by anterior cervical approach and C2-C3 trans-cortical screw placement

    Directory of Open Access Journals (Sweden)

    Agrawal Amit

    2018-03-01

    Full Text Available Cervical spine injuries are the major cause of morbidity and mortality in trauma victims. Upper cervical spine injuries account for about 24% of acute fractures and dislocations and one third of fractures occur at the level of C2, while one half of injuries occur at the C6 or C7 levels. In contrast to this approach we used the transverse cervical, platysma splitting incision at a lower (C3-C4 disc to expose the upper cervical spine particularly lower border of C3 (entry point for the screw.

  6. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware.

    Science.gov (United States)

    Windolf, Markus; Klos, Kajetan; Wähnert, Dirk; van der Pol, Bas; Radtke, Roman; Schwieger, Karsten; Jakob, Roland P

    2010-05-21

    Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence") utilizing conventional (non-locked) implants in comparison to conventional LC-DCP (limited contact dynamic compression plate) and LCP (locking compression plate) stabilization, in a human cadaveric diaphyseal gap model. In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  7. Minimally invasive locked plating of distal tibia fractures is safe and effective.

    Science.gov (United States)

    Ronga, Mario; Longo, Umile Giuseppe; Maffulli, Nicola

    2010-04-01

    Distal tibial fractures are difficult to manage. Limited soft tissue and poor vascularity impose limitations for traditional plating techniques that require large exposures. The nature of the limitations for traditional plating techniques is intrinsic to the large exposure required to approach distal tibia, a bone characterized by limited soft tissue coverage and poor vascularity. The locking plate (LP) is a new device for treatment of fractures. We assessed the bone union rate, deformity, leg-length discrepancy, ankle range of motion, return to preinjury activities, infection, and complication rate in 21 selected patients who underwent minimally invasive osteosynthesis of closed distal tibia fractures with an LP. According to the AO classification, there were 12 Type A, 5 Type B, and 4 Type C fractures. The minimum followup was 2 years (average, 2.8 years; range, 2-4 years). Two patients were lost to followup. Union was achieved in all but one patient by the 24th postoperative week. Four patients had angular deformity less than 7 degrees . No patient had a leg-length discrepancy more than 1.1 cm. Five patients had ankle range of motion less than 20 degrees compared with the contralateral side. Sixteen patients had not returned to their preinjury sporting or leisure activities. Three patients developed a delayed infection. We judge the LP a reasonable device for treating distal tibia fractures. The level of physical activities appears permanently reduced in most patients. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  8. Anterior avulsion fracture of the tibial tuberosity in adolescents - Two case reports

    Directory of Open Access Journals (Sweden)

    Aleilimar Teixeira da Silva Júnior

    Full Text Available ABSTRACT The objective here was to report two rare cases of anterior avulsion fracture of the tibial tuberosity in adolescents. Case 1 was a 15-year-old male who became injured through landing on his left knee and presented limited extension. Case 2 was a 16-year-old basketball player who presented sudden pain in the right knee and functional incapacity, after a jump. Imaging examinations (radiographs and computed tomography showed anterior avulsion fractures of the tibial tuberosity. Surgical fixation was performed using screws and anchors, while avoiding growth plate injury. The cases evolved without lower-limb deformities.

  9. Gliding arc surface treatment of glass-fiber-reinforced polyester enhanced by ultrasonic irradiation

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Norrman, Kion; Drews, Joanna Maria

    2011-01-01

    . The efficiency of such a plasma treatment at atmospheric pressure can be further improved by ultrasonic irradiation onto the surface during the treatment. In the present work glass fiber reinforced polyester (GFRP) plates are treated using an atmospheric pressure gliding arc with and without ultrasonic...

  10. Clavicle hook plate fixation for displaced lateral-third clavicle fractures (Neer type II): a functional outcome study.

    LENUS (Irish Health Repository)

    Good, Daniel W

    2012-08-01

    Controversy exists with the use of the acromioclavicular hook plate for the treatment of lateral-third clavicle fractures (Neer type II). This is thought to stem from problems associated with the hook plate causing impingement symptoms, which can cause long-term limitation of movement and pain. Our aim was to evaluate the functional outcomes of patients with lateral-third clavicle fractures treated with the hook plate.

  11. Slab fractures of the third tarsal bone: Minimally invasive repair using a single 3.5 mm cortex screw placed in lag fashion in 17 Thoroughbred racehorses.

    Science.gov (United States)

    Barker, W H J; Wright, I M

    2017-03-01

    A technique for minimally invasive repair of slab fractures of the third tarsal bone has not previously been reported. Results of third tarsal bone slab fracture repair in Thoroughbred racehorses are lacking. To report the outcomes of repair of uniplanar frontal slab factures of the third tarsal bone using a single 3.5 mm cortex screw in lag fashion. Retrospective case series. Case records of horses that had undergone this procedure were reviewed. Seventeen horses underwent surgery. Eighteen percent of cases had wedge shaped third tarsal bones. A point midway between the long and lateral digital extensor tendons and centrodistal and tarsometatarsal joints created a suitable entry site for implants. The fracture location, configuration and curvature of the third tarsal bone and associated joints requires a dorsolateral proximal-plantaromedial distal trajectory for the screw, which was determined by preplaced needles. There were no complications and fractures healed in all cases at 4-6 months post surgery. Seventy-nine percent of horses returned to racing and, at the time of reporting, 3 are in post operative rehabilitation programmes. The technique reported provides a safe, appropriate and repeatable means of repairing slab fractures of the third tarsal bone. Surgical repair is a viable alternative to conservative management. © 2016 EVJ Ltd.

  12. Initial outcome and efficacy of S3 proximal humerus locking plate in the treatment of proximal humerus fractures

    International Nuclear Information System (INIS)

    Zhang Zhiming; Zhu Xuesong; Bao Zhaohua; Yang Huilin

    2012-01-01

    Objective: to explore the initial outcome and efficacy of S 3 proximal humerus locking plate in the treatment of proximal humerus fractures. Methods: Twenty-two patients with proximal humerus fracture were treated with the S 3 proximal humerus locking plate. Most of the fractures were complex, two-part (n=4), three-part (n=11) and four-part (n=7) fractures according to the Neer classification of the proximal humerus fractures. Results: All patients were followed up for 3∼15 months. There were no complications related to the implant including loosening or breakage of the plate. Good and excellent results were documented in 17 patients fair results in 4 patients according the Neer scores of shoulder. Conclusion: New design concepts of S 3 proximal humerus plate provide the subchondral support and the internal fixation support. With the addition of the proper exercise of the shoulder joint, the outcomes would be satisfied. (authors)

  13. Elderly patient's mortality and morbidity following trochanteric fracture. A prospective study of 100 cases.

    Science.gov (United States)

    Mnif, H; Koubaa, M; Zrig, M; Trabelsi, R; Abid, A

    2009-11-01

    Trochanteric fractures are a major source of mortality, morbidity and functional impairment in the elderly. Morbidity is closely related to the degree of instability and comminution and is substantially influenced by the quality of reduction and internal fixation. Advanced age and associated co-morbidities are two decisive factors of mortality secondary to trochanteric fracture. This prospective study examined the epidemiological profile of trochanteric fractures and assessed mortality and morbidity with the aim of establishing management guidelines and improving prevention strategies. One hundred patients were included; 60% were male. Mean age was 76 years (range, 60-96 yrs). One, or more than one, co-morbidities were present in 68% of cases. The fractures were caused by a simple fall in 90% of cases. Fractures were classified according to the criteria of Ramadier and the ones of Ender. Sixty-five percent of these fractures were unstable. A dynamic hip screw was systematically used as the standard means of internal fixation. Anatomic and functional results were analyzed in 82 patients (18 had died within the first year following fracture occurrence). Mean follow-up period was 24 months (range, 12-36 months). Bone healing was achieved in 96% of cases. There were numerous postoperative complications (four cases of thromboembolism, fourteen immobility-related complications, two infections, six secondary displacement combined to loss of fixation, four non-unions, and nine malunions). At 2 years follow-up, 28 patients had died. Mortality was strongly correlated with older age (over 90 years), associated co-morbidity and fracture instability. Good functional outcomes (72%) correlated with younger age (60-74 years), fracture stability, adequate reduction and internal fixation. In stable trochanteric fractures, osteosynthesis by dynamic screw-plate is more effective than alternative techniques (blade-plate, nail-plate, Ender nail or even trochanteric nail). In unstable

  14. Fracture Characteristics Analysis of Double-layer Rock Plates with Both Ends Fixed Condition

    Directory of Open Access Journals (Sweden)

    S. R. Wang

    2014-07-01

    Full Text Available In order to research on the fracture and instability characteristics of double-layer rock plates with both ends fixed, the three-dimension computational model of double-layer rock plates under the concentrated load was built by using PFC3D technique (three-dimension particle flow code, and the mechanical parameters of the numerical model were determined based on the physical model tests. The results showed the instability process of the double-layer rock plates had four mechanical response phases: the elastic deformation stage, the brittle fracture of upper thick plate arching stage, two rock-arch bearing stage and two rock-arch failure stage; moreover, with the rock plate particle radius from small to large change, the maximum vertical force of double rock-arch appeared when the particle size was a certain value. The maximum vertical force showed an upward trend with the increase of the rock plate temperature, and in the case of the same thickness the maximum vertical force increased with the increase of the upper rock plate thickness. When the boundary conditions of double-layer rock plates changed from the hinged support to the fixed support, the maximum horizontal force observably decreased, and the maximum vertical force showed small fluctuations and then tended towards stability with the increase of cohesive strength of double-layer rock plates.

  15. Fractures of the distal tibia treated with polyaxial locking plating.

    Science.gov (United States)

    Gao, Hong; Zhang, Chang-Qing; Luo, Cong-Feng; Zhou, Zu-Bin; Zeng, Bing-Fang

    2009-03-01

    We evaluated the healing rate, complications, and functional outcomes in 32 adult patients with very short metaphyseal fragments in fractures of the distal tibia treated with a polyaxial locking system. The average distance from the distal extent of the fracture to the tibial plafond was 11 mm. All fractures healed and the average time to union was 14 weeks. Six patients (19%) reported occasional local disturbance over the medial malleolus. There were two cases of postoperative superficial infections and evidence of delayed wound healing. Using the American Orthopaedic Foot and Ankle Society ankle score, the average functional score was 87.3 points (of 100 total possible points). Our results show the polyaxial locking plates, which offer more fixation versatility, may be a reasonable treatment option for distal tibia fractures with very short metaphyseal segments.

  16. To retain or remove the syndesmotic screw: a review of literature

    NARCIS (Netherlands)

    T. Schepers (Tim)

    2011-01-01

    textabstractIntroduction: Syndesmotic positioning screws are frequently placed in unstable ankle fractures. Many facets of adequate placement techniques have been the subject of various studies. Whether or not the syndesmosis screw should be removed prior to weight-bearing is still debated. In this

  17. Minimally invasive treatment of pilon fractures with a low profile plate: preliminary results in 17 cases.

    Science.gov (United States)

    Borens, Olivier; Kloen, Peter; Richmond, Jeffrey; Roederer, Goetz; Levine, David S; Helfet, David L

    2009-05-01

    To determine the results of "biologic fixation" with a minimally invasive plating technique using a newly designed low profile "Scallop" plate in the treatment of pilon fractures. Retrospective case series. A tertiary referral center. Seventeen patients were treated between 1999 and 2001 for a tibial plafond fracture at the Hospital for Special Surgery with a newly designed low-profile plate. Eleven of the fractures (65%) were high-energy injuries. Two fractures were open. Staged surgical treatment with open reduction and fixation of the fibular fracture and application of an external fixator was performed in 12 cases. As soon as the soft tissues and swelling allowed, i.e. skin wrinkling, the articular surface was reconstructed and simply reduced, if necessary through an small incision, and the articular block was fixed to the diaphysis using a medially placed, percutaneously introduced flat scallop plate. In the remaining five cases the operation was performed in one session. Time to healing and complications including delayed union, non-union, instrument failure, loss of fixation, infection, quality of reduction and number of reoperations were evaluated. Quality of results and outcome were graded using the ankle-hindfoot-scale and a modified rating system. All patients went on to bony union at an average time of 14 weeks. There were no plate failures or loss of fixation/reduction. Two superficial wound-healing problems resolved with local wound care. At an average follow up of 17 months (range 6-29 months) eight patients (47%) had an excellent result; seven (41%) had a fair result whereas two (12%) had a poor result. The average ankle-hindfoot-score was 86.1 (range 61-100). Four patients have had the hardware removed and one of them is awaiting an ankle arthrodesis. Based on these initial results, it appears that a minimally invasive surgical technique including new low profile plate can decrease soft tissue problems while leading to fracture healing and

  18. Comparison of Absorbable Mesh Plate versus Titanium-Dynamic Mesh Plate in Reconstruction of Blow-Out Fracture: An Analysis of Long-Term Outcomes

    Directory of Open Access Journals (Sweden)

    Woon Il Baek

    2014-07-01

    Full Text Available Background A blow-out fracture is one of the most common facial injuries in midface trauma. Orbital wall reconstruction is extremely important because it can cause various functional and aesthetic sequelae. Although many materials are available, there are no uniformly accepted guidelines regarding material selection for orbital wall reconstruction. Methods From January 2007 to August 2012, a total of 78 patients with blow-out fractures were analyzed. 36 patients received absorbable mesh plates, and 42 patients received titanium-dynamic mesh plates. Both groups were retrospectively evaluated for therapeutic efficacy and safety according to the incidence of three different complications: enophthalmos, extraocular movement impairment, and diplopia. Results For all groups (inferior wall fracture group, medial wall fractrue group, and combined inferomedial wall fracture group, there were improvements in the incidence of each complication regardless of implant types. Moreover, a significant improvement of enophthalmos occurred for both types of implants in group 1 (inferior wall fracture group. However, we found no statistically significant differences of efficacy or complication rate in every groups between both implant types. Conclusions Both types of implants showed good results without significant differences in long-term follow up, even though we expected the higher recurrent enophthalmos rate in patients with absorbable plate. In conclusion, both types seem to be equally effective and safe for orbital wall reconstruction. In particular, both implant types significantly improve the incidence of enophthalmos in cases of inferior orbital wall fractures.

  19. Functional Results of Unstable (Type 2 Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

    Directory of Open Access Journals (Sweden)

    Rajesh Govindasamy

    2017-11-01

    Full Text Available Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior locking plate.Methods: From June 2011 to August 2015 a retrospective study of12 male patients (mean age of 41.3 years 11 withunilateral and 1 with bilateral distal clavicle fractures treated with superior anterior locking plate was done. They wereevaluated at regular intervals with mean follow up of 14 months(12-18 months.Those with minimum one year followup were included in our study. All were evaluated for the functioning of the shoulder joint by both Oxford shoulder scoreand Quick DASH scores, rate of bone union, complications and earliest time for return to work.Results: All fractures union seen within 6-8 weeks (mean time: 7.1 weeks.All had good shoulder range of motion. Theaverage oxford shoulder and Quick DASH score were 46.2 and 6.5.There were no major complications in our studyviz. non-union, plate failure, secondary fracture. But one patient had superficial wound infection. All patients returned towork within 3 months of postoperative period.Conclusion: Displaced distal clavicle fractures treated with superior anterior locking plates achieved excellent resultsin terms of bony union with rarely any complications and demonstrate promising results with this novel technique.

  20. The Dynamic Locking Blade Plate : innovation in the treatment of femoral neck fractures

    NARCIS (Netherlands)

    Roerdink, W.H.

    2011-01-01

    The scope of this thesis was to describe the design and development of the Dynamic Locking Blade Plate (DLBP), an improved internal fixation (IF) device for intracapsular hip fractures. This thesis focuses on intracapsular hip fractures since the results of current surgical treatment of this type of

  1. Plating versus wiring for fixation of traumatic rib and sternal fractures

    Directory of Open Access Journals (Sweden)

    Mostafa Kamel Abd-Elnaim

    2017-12-01

    Conclusions: Plating of rib and sternal fractures had better outcome than wiring, regarding better chest wall stability and restoration of chest contour; also it had shorter intensive care unit, hospital and ventilator days.

  2. [Effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture].

    Science.gov (United States)

    Yan, Rongliang; Qu, Jiafu; Cao, Lihai; Liu, Hongda; Chen, Jianghua; Gao, Yan; Peng, Yi

    2018-05-01

    To summarize the effectiveness of mini locking plate combined with Kirschner wire in treatment of comminuted Jones fracture. Between January 2011 and October 2016, 25 cases with comminuted Jones fracture were treated with mini locking plate combined with Kirschner wire. There were 9 males and 16 females with an average age of 31.4 years (range, 16-66 years). The fractures located on the left side in 11 cases and on the right side in 14 cases. The causes of injury included spraining in 21 cases, falling down in 3 cases, and bruise in 1 case. The bone fragment of all cases was more than 3 pieces. The fracture line was mostly Y-shape or T-shape. Twelve of them were combined with other fractures. The time from injury to operation was 1-9 days (mean, 5 days). The mini locking plate and Kirschner wire were removed at 9-12 months postoperatively. At 12 months postoperatively, the pain was evaluated by the visual analogue scale (VAS) score, and the function by the American Orthopaedic Foot & Ankle Society (AOFAS) score. All incisions healed by first intention. All cases were followed up 12-36 months with an average of 21.7 months. Fracture union was observed in all patients without complications such as nonunion, delayed union, and malunion. The fracture union time was 8-12 weeks (mean, 9.4 weeks). At 12 months postoperatively, the VAS score was 1.15±0.87; the AOFAS score was 89.45±6.24, and the results were excellent in 14 cases, good in 9 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 92%. The procedure of mini locking plate combined with Kirschner wire for comminuted Jones fracture has such advantages as convenient operation, more rigid fixation, high rate of fracture healing, and good functional recovery in foot.

  3. Anterior Z-plate and titanic mesh fixation for acute burst thoracolumbar fracture.

    Science.gov (United States)

    Xu, Jian-Guang; Zeng, Bing-Fang; Zhou, Wei; Kong, Wei-Qing; Fu, Yi-Shan; Zhao, Bi-Zeng; Zhang, Tao; Lian, Xiao-Feng

    2011-04-01

    A retrospective study. To evaluate the clinical outcome, effectiveness, and security of the surgical management of acute thoracolumbar burst fracture with corpectomy, titanic mesh autograft, and Z-plate fixation by anterior approach. Many surgical methods were adopted to treat acute burst thoracolumbar fracture. But the optimal surgical management remains controversial. A retrospective review of a consecutive series of 48 patients with thoracolumbar burst fracture treated with anterior corpectomy, titanic mesh autograft, and Z-plate internal fixation was carried out. Preoperative clinical and radiographic data of all cases were originally collected. Surgical indications were motor neurologic deficit and thoracolumbar column instability. Twenty-two patients (45.8%) with acute thoracolumbar burst fractures presented with a neurologic deficit. The postoperative recovery of neural function, restoration of anterior cortex collapse, kyphotic angle, and spinal canal compromise were observed. The preoperative kyphotic angle was improved to a mean of 5.6°, radiographic height restored to 95.8% of the adjacent normal levels, and canal compromise was 0%. None of the patients had neurologic deterioration. Mean follow-up time was 32.4 months (range, 24-47 months). All 22 patients with neurologic deficit demonstrated at least one Frankel grade improvement on final observation, with 16 (73%) patients had accomplished complete neurologic recovery. Forty-six (96%) patients reported minimal or no pain at final follow-up observation, and 40 (83%) patients who had been working before injury returned to original work. The authors considered spinal cord decompression with anterior corpectomy and stability reconstruction with titanic mesh autograft and Z-plate fixation at same time in one incision as an effective technique for unstable thoracolumbar burst fracture with and without neurologic deficit.

  4. To retain or remove the syndesmotic screw: a review of literature

    NARCIS (Netherlands)

    Schepers, T.

    2011-01-01

    Syndesmotic positioning screws are frequently placed in unstable ankle fractures. Many facets of adequate placement techniques have been the subject of various studies. Whether or not the syndesmosis screw should be removed prior to weight-bearing is still debated. In this study, the recent

  5. [APPLICATION OF BUTTERFLY SHAPED LOCKING COMPRESSION PLATE IN COMPLEX DISTAL RADIUS FRACTURES].

    Science.gov (United States)

    Jiang, Zongyuan; Ma, Tao; Xia, Jiang; Hu, Caizhi; Xu, Lei

    2014-06-01

    To investigate the effectiveness of butterfly shaped locking compression plate for the treatment of complex distal radius fractures. Between June 2011 and January 2013, 20 cases of complex distal radius fractures were treated with butterfly shaped locking compression plate fixation. There were 11 males and 9 females with an average age of 54 years (range, 25-75 years). Injury was caused by falling in 10 cases, by traffic accident in 7 cases, and by falling from height in 3 cases. All of fractures were closed. According to AO classification system, there were 8 cases of type C1, 8 cases of type C2, and 4 cases of type C3. Of them, 9 cases had radial styloid process fracture, 4 cases had sigmoid notch fracture, and 7 cases had both radial styloid process fracture and sigmoid notch fracture. The mean interval between injury and operation was 5.2 days (range, 3-15 days). All incisions healed by first intention; no complications of infection and necrosis occurred. All cases were followed up 14 months on average (range, 10-22 months). All factures healed after 9.3 weeks on average (range, 6-11 weeks). No complications such as displacement of fracture, joint surface subsidence, shortening of the radius, and carpal tunnel syndrome were found during follow-up. At last follow-up, the mean palmar tilt angle was 10.2° (range, 7-15°), and the mean ulnar deviation angle was 21.8° (range, 17-24°). The mean range of motion of the wrist was 45.3° (range, 35-68°) in dorsal extension, 53.5° (range, 40-78°) in palmar flexion, 19.8° (range, 12-27°) in radial inclination, 26.6° (range, 18-31°) in ulnar inclination, 70.2° (range, 45-90°) in pronation, and 68.4° (range, 25-88°) in supination. According to the Dienst scoring system, the results were excellent in 8 cases, good in 10 cases, and fair in 2 cases, and the excellent and good rate was 90%. Treatment of complex distal radius fractures with butterfly shaped locking compression plate can reconstruct normal anatomic

  6. Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    OpenAIRE

    Nauth, A. (Aaron); Creek, A.T. (Aaron T.); Zellar, A. (Abby); Lawendy, A.-R. (Abdel-Rahman); Dowrick, A. (Adam); Gupta, A. (Ajay); Dadi, A. (Akhil); Kampen, A.; Yee, A. (Albert); Vries, Alexander; de Mol van Otterloo, A. (Alexander); Garibaldi, A. (Alisha); Liew, A. (Allen); McIntyre, A.W. (Allison W.); Prasad, A.S. (Amal Shankar)

    2017-01-01

    textabstractBackground Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a...

  7. Decision Making in the Management of Extracapsular Fractures of the Proximal Femur - is the Dynamic Hip Screw the Prevailing Gold Standard?

    Science.gov (United States)

    Jacob, Joshua; Desai, Ankit; Trompeter, Alex

    2017-01-01

    Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the 'gold standard' implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve.

  8. Stress corrosion cracking lifetime prediction of spring screw

    International Nuclear Information System (INIS)

    Koh, S. K.; Ryu, C. H.

    2004-01-01

    A lifetime prediction of holddown spring screw in nuclear fuel assembly was performed using fracture mechanics approach. The spring screw was designed such that it was capable of sustaining the loads imposed by the initial tensile preload and operational loads. In order to investigate the cause of failure and to predict the stress corrosion cracking life of the screw, a stress analysis of the top nozzle spring assembly was done using finite element analysis. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Normalized stress intensity factors for PWSCC life prediction was proposed. Primary water stress corrosion cracking life of the Inconel 600 screw was predicted by using integration of the Scott model and resulted in 1.78 years, which was fairly close to the actual service life of the holddown spring screw

  9. [Anterior odontoid screw fixation using intra-operative cone-beam computed tomography and navigation].

    Science.gov (United States)

    Castro-Castro, Julián

    2014-01-01

    The purpose of this study was to asses the value of intraoperative cone-beam CT (O-arm) and stereotactic navigation for the insertion of anterior odontoid screws. this was a retrospective review of patients receiving surgical treatment for traumatic odontoid fractures during a period of 18 months. Procedures were guided with O-arm assistance in all cases. The screw position was verified with an intraoperative CT scan. Intraoperative and clinical parameters were evaluated. Odontoid fracture fusion was assessed on postoperative CT scans obtained at 3 and 6 months' follow-up Five patients were included in this series; 4 patients (80%) were male. Mean age was 63.6 years (range 35-83 years). All fractures were acute type ii odontoid fractures. The mean operative time was 116minutes (range 60-160minutes). Successful screw placement, judged by intraoperative computed tomography, was attained in all 5 patients (100%). The average preoperative and postoperative times were 8.6 (range 2-22 days) and 4.2 days (range 3-7 days) respectively. No neurological deterioration occurred after surgery. The rate of bone fusion was 80% (4/5). Although this initial study evaluated a small number of patients, anterior odontoid screw fixation utilizing the O-arm appears to be safe and accurate. This system allows immediate CT imaging in the operating room to verify screw position. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  10. The best location for proximal locking screw for femur interlocking nailing: A biomechanical study

    Directory of Open Access Journals (Sweden)

    Ahmet A Karaarslan

    2016-01-01

    Conclusion: According to our findings, there is twice as much difference in locking screw bending resistance between these two application levels. To avoid proximal locking screw deformation, locking screws should be placed in the level of the lesser trochanter in nailing of 1/3 middle and distal femur fractures.

  11. The Screw-Like Movement of a Gliding Bacterium Is Powered by Spiral Motion of Cell-Surface Adhesins.

    Science.gov (United States)

    Shrivastava, Abhishek; Roland, Thibault; Berg, Howard C

    2016-09-06

    Flavobacterium johnsoniae, a rod-shaped bacterium, glides over surfaces at speeds of ∼2 μm/s. The propulsion of a cell-surface adhesin, SprB, is known to enable gliding. We used cephalexin to generate elongated cells with irregular shapes and followed their displacement in three dimensions. These cells rolled about their long axes as they moved forward, following a right-handed trajectory. We coated gold nanoparticles with an SprB antibody and tracked them in three dimensions in an evanescent field where the nanoparticles appeared brighter when they were closer to the glass. The nanoparticles followed a right-handed spiral trajectory on the surface of the cell. Thus, if SprB were to adhere to the glass rather than to a nanoparticle, the cell would move forward along a right-handed trajectory, as observed, but in a direction opposite to that of the nanoparticle. Copyright © 2016 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  12. The clinical application of absorbable intramedullary nail and claw plate on treating multiple rib fractures.

    Science.gov (United States)

    Chai, X; Lin, Q; Ruan, Z; Zheng, J; Zhou, J; Zhang, J

    2013-08-01

    The absorption intramedullary nail and claw plate indications and efficacy were investigated in the treatment of a life-threatening multiple rib fractures. A retrospective analysis of 248 surgically treated rib fracture patients was performed who admitted to our hospital from March 2007 to December 2012. Intramedullary nailing was performed in 28 cases, a claw-type bone plate was fixed in 141 cases, and a combination of both was fixed in 79 cases. All internal fixation patients were clinically cured except 1 patient died 14 days after a massive pulmonary embolism. The patients with flail chest and floating chest wall causing respiratory and circulatory disorders were promptly corrected. Routine follow-up was from 1 to 2 years, displaced fractures were in 2 cases, and there were 11 cases of internal fixation and extraction. Internal fixation is a simple and reliable method for the treatment of multiple rib fractures. Both internal fixation materials have their pros and cons but the claw bone plate is more robust. The actual selection of appropriate treatment options helps to improve the treatment efficacy.

  13. The Impact of Nitinol Staples on the Compressive Forces, Contact Area, and Mechanical Properties in Comparison to a Claw Plate and Crossed Screws for the First Tarsometatarsal Arthrodesis.

    Science.gov (United States)

    Aiyer, Amiethab; Russell, Nicholas A; Pelletier, Matthew H; Myerson, Mark; Walsh, William R

    2016-06-01

    Background The optimal fixation method for the first tarsometatarsal arthrodesis remains controversial. This study aimed to develop a reproducible first tarsometatarsal testing model to evaluate the biomechanical performance of different reconstruction techniques. Methods Crossed screws or a claw plate were compared with a single or double shape memory alloy staple configuration in 20 Sawbones models. Constructs were mechanically tested in 4-point bending to 1, 2, and 3 mm of plantar displacement. The joint contact force and area were measured at time zero, and following 1 and 2 mm of bending. Peak load, stiffness, and plantar gapping were determined. Results Both staple configurations induced a significantly greater contact force and area across the arthrodesis than the crossed screw and claw plate constructs at all measurements. The staple constructs completely recovered their plantar gapping following each test. The claw plate generated the least contact force and area at the joint interface and had significantly greater plantar gapping than all other constructs. The crossed screw constructs were significantly stiffer and had significantly less plantar gapping than the other constructs, but this gapping was not recoverable. Conclusions Crossed screw fixation provides a rigid arthrodesis with limited compression and contact footprint across the joint. Shape memory alloy staples afford dynamic fixation with sustained compression across the arthrodesis. A rigid polyurethane foam model provides an anatomically relevant comparison for evaluating the interface between different fixation techniques. Clinical Relevance The dynamic nature of shape memory alloy staples offers the potential to permit early weight bearing and could be a useful adjunctive device to impart compression across an arthrodesis of the first tarsometatarsal joint. Therapeutic, Level V: Bench testing. © 2015 The Author(s).

  14. Studies on positive conveying in helically channeled single screw extruders

    Directory of Open Access Journals (Sweden)

    L. Pan

    2012-07-01

    Full Text Available A solids conveying theory called double-flight driving theory was proposed for helically channeled single screw extruders. In the extruder, screw channel rotates against static barrel channel, which behaves as cooperative embedded twin-screws for the positive conveying. They turn as two parallel arc plates, between which an arc-plate solid-plug was assumed. By analyzing the forces on the solid-plug in the barrel channel and screw channel, the boundary conditions when the solid-plug is waived of being cut off on barrel wall, were found to have the capacity of the positive conveying. Experimental data were obtained using a specially designed extruder with a helically channeled barrel in the feeding zone and a pressure-adjustable die. The effects of the barrel channel geometry and friction coefficients on the conveying mechanism were presented and compared with the experimental results. The simulations showed that the positive conveying could be achieved after optimizing extruder designs. Compared with the traditional design with the friction-drag conveying, the throughput is higher while screw torque and energy consumption are decreased. Besides, the design criteria of the barrel channel were also discussed.

  15. Anterior-inferior tibiofibular ligament anatomical repair and augmentation versus trans-syndesmosis screw fixation for the syndesmotic instability in external-rotation type ankle fracture with posterior malleolus involvement: A prospective and comparative study.

    Science.gov (United States)

    Zhan, Yu; Yan, Xiaoyu; Xia, Ronggang; Cheng, Tao; Luo, Congfeng

    2016-07-01

    Syndesmosis injury is common in external-rotation type ankle fractures (ERAF). Trans-syndesmosis screw fixation, the gold-standard treatment, is currently controversial for its complications and biomechanical disadvantages. The purpose of this study was to introduce a new method of anatomically repairing the anterior-inferior tibiofibular ligament (AITFL) and augmentation with anchor rope system to treat the syndesmotic instability in ERAF with posterior malleolus involvement and to compare its clinical outcomes with that of trans-syndesmosis screw fixation. 53 ERAFs with posterior malleolus involvement received surgery, and the syndesmosis was still unstable after fracture fixation. They were randomised into screw fixation group and AITFL anatomical repair with augmentation group. Reduction quality, syndesmosis diastasis recurrence, pain (VAS score), time back to work, Olerud-Molander ankle score and range of motion (ROM) of ankle were investigated. Olerud-Molander score in AITFL repair group and screw group was 90.4 and 85.8 at 12-month follow-up (P>0.05). Plantar flexion was 31.2° and 34.3° in repair and screw groups (P=0.04). Mal-reduction happened in 5 cases (19.2%) in screw group while 2 cases (7.4%) in repair group. Postoperative syndesmosis re-diastasis occurred in 3 cases in screw group while zero in repair group (P>0.05). Pain score was similar between the two groups (P>0.05). Overall complication rate and back to work time were 26.9% and 3.7% (P=0.04), 7.15 months and 5.26 months (P=0.02) in screw group and repair group, respectively. For syndesmotic instability in ERAF with posterior malleolus involvement, the method of AITFL anatomical repair and augmentation with anchor rope system had an equivalent functional outcome and reduction, earlier rehabilitation and less complication compared with screw fixation. It can be selected as an alternative. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Tension band plating of a nonunion anterior tibial stress fracture in an athlete.

    Science.gov (United States)

    Merriman, Jarrad A; Villacis, Diego; Kephart, Curtis J; Rick Hatch, George F

    2013-07-01

    The authors present a rare technique of tension band plating of the anterior tibia in the setting of a nonunion stress fracture. Surgical management with an intramedullary nail is a viable and proven option for treating such injuries. However, in treating elite athletes, legitimate concerns exist regarding the surgical disruption of the extensor mechanism and the risk of anterior knee pain associated with intramedullary nail use. The described surgical technique demonstrates the use of tension band plating as an effective treatment of delayed union and nonunion anterior tibial stress fractures in athletes without the potential risks of intramedullary nail insertion. Copyright 2013, SLACK Incorporated.

  17. 2D and 3D assessment of sustentaculum tali screw fixation with or without Screw Targeting Clamp.

    Science.gov (United States)

    De Boer, A Siebe; Van Lieshout, Esther M M; Vellekoop, Leonie; Knops, Simon P; Kleinrensink, Gert-Jan; Verhofstad, Michael H J

    2017-12-01

    Precise placement of sustentaculum tali screw(s) is essential for restoring anatomy and biomechanical stability of the calcaneus. This can be challenging due to the small target area and presence of neurovascular structures on the medial side. The aim was to evaluate the precision of positioning of the subchondral posterior facet screw and processus anterior calcanei screw with or without a Screw Targeting Clamp. The secondary aim was to evaluate the added value of peroperative 3D imaging over 2D radiographs alone. Twenty Anubifix™ embalmed, human anatomic lower limb specimens were used. A subchondral posterior facet screw and a processus anterior calcanei screw were placed using an extended lateral approach. A senior orthopedic trauma surgeon experienced in calcaneal fracture surgery and a senior resident with limited experience in calcaneal surgery performed screw fixation in five specimens with and in five specimens without the clamp. 2D lateral and axial radiographs and a 3D recording were obtained postoperatively. Anatomical dissection was performed postoperatively as a diagnostic golden standard in order to obtain the factual screw positions. Blinded assessment of quality of fixation was performed by two surgeons. In 2D, eight screws were considered malpositioned when placed with the targeting device versus nine placed freehand. In 3D recordings, two additional screws were malpositioned in each group as compared to the golden standard. As opposed to the senior surgeon, the senior resident seemed to get the best results using the Screw Targeting Clamp (number of malpositioned screws using freehand was eight, and using the targeting clamp five). In nine out of 20 specimens 3D images provided additional information concerning target area and intra-articular placement. Based on the 3D assessment, five additional screws would have required repositioning. Except for one, all screw positions were rated equally after dissection when compared with 3D examinations

  18. Reverse Less Invasive Stabilization System (LISS) Plating for Proximal Femur Fractures in Poliomyelitis Survivors: A Report of Two Cases.

    Science.gov (United States)

    Yao, Chen; Jin, Dongxu; Zhang, Changqing

    2017-11-15

    BACKGROUND Poliomyelitis is a neuromuscular disease which causes muscle atrophy, skeletal deformities, and disabilities. Treatment of hip fractures on polio-affect limbs is unique and difficult, since routine fixation methods like nailing may not be suitable due to abnormal skeletal structures. CASE REPORT We report one femoral neck fracture and one subtrochanteric fracture in polio survivors successfully treated with reverse less invasive stabilization system (LISS) plating technique. Both fractures were on polio-affected limbs with significant skeletal deformities and low bone density. A contralateral femoral LISS plate was applied upside down to the proximal femur as an internal fixator after indirect or direct reduction. Both patients had uneventful bone union and good functional recovery. CONCLUSIONS Reverse LISS plating is a safe and effective technique to treat hip fractures with skeletal deformities caused by poliomyelitis.

  19. Hollow Mill for Extraction of Stripped Titanium Screws: An Easy ...

    African Journals Online (AJOL)

    countries. The known alternative in such condition is ... Key words: Hollow mill, stripped screws, titanium locked plates ... used a locally manufactured stainless steel hollow mill, ... head ‑ plate hole” assembly as a mono‑block single unit. In.

  20. Cement augmentation of implants--no general cure in osteoporotic fracture treatment. A biomechanical study on non-displaced femoral neck fractures.

    Science.gov (United States)

    Hofmann-Fliri, Ladina; Nicolino, Tomas I; Barla, Jorge; Gueorguiev, Boyko; Richards, R Geoff; Blauth, Michael; Windolf, Markus

    2016-02-01

    Femoral neck fractures in the elderly are a common problem in orthopedics. Augmentation of screw fixation with bone cement can provide better stability of implants and lower the risk of secondary displacement. This study aimed to investigate whether cement augmentation of three cannulated screws in non-displaced femoral neck fractures could increase implant fixation. A femoral neck fracture was simulated in six paired human cadaveric femora and stabilized with three 7.3 mm cannulated screws. Pairs were divided into two groups: conventional instrumentation versus additional cement augmentation of screw tips with 2 ml TraumacemV+ each. Biomechanical testing was performed by applying cyclic axial load until failure. Failure cycles, axial head displacement, screw angle changes, telescoping and screw cut-out were evaluated. Failure (15 mm actuator displacement) occurred in the augmented group at 12,500 cycles (± 2,480) compared to 15,625 cycles (± 4,215) in the non-augmented group (p = 0.041). When comparing 3 mm vertical displacement of the head no significant difference (p = 0.72) was detected between the survival curves of the two groups. At 8,500 load-cycles (early onset failure) the augmented group demonstrated a change in screw angle of 2.85° (± 0.84) compared to 1.15° (± 0.93) in the non-augmented group (p = 0.013). The results showed no biomechanical advantage with respect to secondary displacement following augmentation of three cannulated screws in a non-displaced femoral neck fracture. Consequently, the indication for cement augmentation to enhance implant anchorage in osteoporotic bone has to be considered carefully taking into account fracture type, implant selection and biomechanical surrounding. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  1. Treatment of unstable fractures, dislocations and fracture-dislocations of the cervical spine with Senegas plate fixation

    NARCIS (Netherlands)

    Moerman, J.; Harth, A.; Trimpont, van I.; Uyttendaele, D.; Verdonk, R.; Claessens, H.A.; Verbeke, S.

    1994-01-01

    The results of the anterior approach to the cervical spine for the treatment of fractures and dislocations by arthrodesis and Senegas plate fixation are described. Twenty-two patients underwent a one- or two-level arthrodesis of the cervical spine. Their mean age was 42 years. The injuries were

  2. Treatment of Middle Third Humeral Shaft Fractures with Anteromedial Plate Osteosynthesis through an Anterolateral Approach.

    Science.gov (United States)

    Kumar, B S; Soraganvi, P; Satyarup, D

    2016-03-01

    Background: Treatment of humeral shaft fractures has been a subject of debate for many decades. Even though a large majority of humeral shaft fractures can be treated by non operative methods, few conditions like open fractures, polytrauma, ipsilateral humeral shaft and forearm fractures require surgical intervention. The goal of treatment of humeral shaft fractures is to establish union with an acceptable humeral alignment and to restore the patient to pre-injury level of function. The objective was to assess the incidence of radial nerve palsy, non-union and mean time required for in anteromedial plate osteosynthesis with anterolateral approach and also to measure the functional outcome of this procedure. Method: A prospective study was conducted in the Department of Orthopaedics, PESIMSR, Kuppam, Andhra Pradesh, from August 2012 to August 2015 with a total of 54 patients who were operated with anteromedial plate osteosynthesis were included in the study. Rodriguez- Merchan criteria was used to grade the functional outcome. Results: Of the 54 patients, 28 (58.85%) were in the age group of 30-40 years. The most common fracture pattern identified was A3 type (48.14%).The mean (± SD) duration of surgery for anteromedial humeral plating was 53 ± 5.00 minutes. The time taken for the fracture to unite was less than 16 weeks in the majority or 50 patients (92.59%). Four (7.40%) patients had delayed union. There was no incidence of iatrogenic radial nerve palsy. Rodriguez - Merchan criteria showed that 37(68.51%) of the patients had good and 12 (22.22%) had excellent functional outcome.

  3. Decision Making in the Management of Extracapsular Fractures of the Proximal Femur – is the Dynamic Hip Screw the Prevailing Gold Standard?

    Science.gov (United States)

    Jacob, Joshua; Desai, Ankit; Trompeter, Alex

    2017-01-01

    Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the ‘gold standard’ implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve. PMID:29290858

  4. Mechanical characteristics of connection for GFRP plates using tapping screws

    Science.gov (United States)

    Inoue, Yuya; Duong, Nguyen Ngoc; Satake, Chito; Matsumoto, Yukihiro

    2017-10-01

    FRP material has good characteristics such as light-weight, high-strength and high-corrosion resistance. Light-weight structure possesses some advantages over the rational constructing procedure such as self-building structures. In recent years, mechanical characteristics of FRP joints using bolts and/or rivet are investigated in detail, and they are used in many FRP structures. However, the bolts lack bearing strength compared with material strength and the joint needs the prepared bolt hole. In this paper, an alternative joint system for FRP structures using tapping screw is proposed and mechanical characteristics are investigated through experiment. Tapping screw has some advantages; easy-to-use, light-weight and high bearing strength. Then, the results of double-lapped tensile shear tests having one, four and eight tapping screws along longitudinal direction are shown. Moreover, it is shown that longitudinal stress distribution is approximately corresponding to the theoretical stress distribution of double-lapped adhesively bonded joints. Based on these, it is proposed that joint strength can be estimated by using the present calculation method.

  5. Comparison of reconstruction plate screw fixation and percutaneous cannulated screw fixation in treatment of Tile B1 type pubic symphysis diastasis: a finite element analysis and 10-year clinical experience.

    Science.gov (United States)

    Yu, Ke-He; Hong, Jian-Jun; Guo, Xiao-Shan; Zhou, Dong-Sheng

    2015-09-22

    The objective of this study is to compare the biomechanical properties and clinical outcomes of Tile B1 type pubic symphysis diastasis (PSD) treated by percutaneous cannulated screw fixation (PCSF) and reconstruction plate screw fixation (RPSF). Finite element analysis (FEA) was used to compare the biomechanical properties between PCSF and RPSF. CT scan data of one PSD patient were used for three-dimensional reconstructions. After a validated pelvic finite element model was established, both PCSF and RPSF were simulated, and a vertical downward load of 600 N was loaded. The distance of pubic symphysis and stress were tested. Then, 51 Tile type B1 PSD patients (24 in the PCSF group; 27 in the RPSF group) were reviewed. Intra-operative blood loss, operative time, and the length of the skin scar were recorded. The distance of pubic symphysis was measured, and complications of infection, implant failure, and revision surgery were recorded. The Majeed scoring system was also evaluated. The maximum displacement of the pubic symphysis was 0.408 and 0.643 mm in the RPSF and PCSF models, respectively. The maximum stress of the plate in RPSF was 1846 MPa and that of the cannulated screw in PCSF was 30.92 MPa. All 51 patients received follow-up at least 18 months post-surgery (range 18-54 months). Intra-operative blood loss, operative time, and the length of the skin scar in the PCSF group were significantly different than those in the RPSF group. No significant differences were found in wound infection, implant failure, rate of revision surgery, distance of pubic symphysis, and Majeed score. PCSF can provide comparable biomechanical properties to RPSF in the treatment of Tile B1 type PSD. Meanwhile, PCSF and RPSF have similar clinical and radiographic outcomes. Furthermore, PCSF also has the advantages of being minimally invasive, has less blood loss, and has shorter operative time and skin scar.

  6. Anatomical evidence for the anterior plate fixation of sacroiliac joint.

    Science.gov (United States)

    Bai, Zhibiao; Gao, Shichang; Liu, Jia; Liang, Anlin; Yu, Weihua

    2018-01-01

    The iatrogenic injuries to the lumbar nerves during the fixation the sacroiliac (SI) joint fractures with anterior plates were often reported. No specific method had been reported to avoid it. This study was done to find a safer way of placing the anterior plates and screws for treating the sacroiliac (SI) joint fracture and/or dislocation. The research was performed using 8 male and 7 female normal corpse pelvic specimens preserved by 10% formalin solution. Try by measuring the horizontal distance from L4, L5 nerve roots to the sacroiliac joint and perpendicular distance from L4, L5 nerve roots to the ala sacralis, the length of L4, L5 nerve roots from intervertebral foramen to the edge of true pelvis, the diameter of L4, L5 nerve roots. The angles between the sacroiliac joint and sagittal plane were measured on the CT images. The horizontal distance between the lateral side of the anterior branches of L4, L5 nerve roots and the sacroiliac joint decreased gradually from the top to the bottom. The widest distances for L4,5 were 2.1 cm (range, 1.74-2.40) and 2.7 cm (range, 2.34-3.02 cm), respectively. The smallest distances for L4, 5 were 1.2 cm (range, 0.82-1.48 cm) and 1.5 cm (range, 1.08-1.74 cm), respectively. On CT images, the angle between the sacroiliac joint and sagittal plane was about 30°. If we use two anterior plates to fix the sacroiliac joint, It is recommended to place one plate on the superior one third part of the joint, with exposing medially no more than 2.5 cm and the other in the middle one third part of the joint, with elevating periosteum medially no more than 1.5 cm. The screws in the sacrum are advised to incline medially about 30° directing to the true pelvis. Copyright © 2017. Published by Elsevier B.V.

  7. Computer-assisted surgery for screw insertion into the distal sesamoid bone in horses: an in vitro study.

    Science.gov (United States)

    Gygax, Diego; Lischer, Christoph; Auer, Joerg A

    2006-10-01

    To compare the precision of computer-assisted surgery with a conventional technique (CV) using a special guiding device for screw insertion into the distal sesamoid bone in horses. In vitro experimental study. Cadaveric forelimb specimens. Insertion of a 3.5 mm cortex screw in lag fashion along the longitudinal axis of intact (non-fractured) distal sesamoid bones was evaluated in 2 groups (8 limbs each): CV and computer-assisted surgery (CAS). For CV, the screw was inserted using a special guiding device and fluoroscopy, whereas for CAS, the screw was inserted using computer-assisted navigation. The accuracy of screw placement was verified by radiography, computed tomography, and specimen dissection. Surgical precision was better in CAS compared with CV. CAS improves the accuracy of lateromedial screw insertion, in lag fashion, into the distal sesamoid bone. The CAS technique should be considered for improved accuracy of screw insertion in fractures of the distal sesamoid bone.

  8. Distal tibial fracture treated by minimally invasive plate osteosynthesis after external fixation Retrospective clinical and radiographic assessment

    Directory of Open Access Journals (Sweden)

    Al. Șerban

    2014-02-01

    Full Text Available Fractures of the horizontal surface of the distal tibia are known commonly as pylon or plafond fractures, and represent 1-5% of lower extremity fractures, 7-10% of all tibial fractures. The protocol consisted of immediate (within eight to 24 hours open reduction and internal fixation of the fibula, using a fibular plate or one third tubular plate and application of an external fixator spanning the ankle joint. In the second stage, the treatment of proximal and distal tibial fractures with close reduction and MIPPO technique can preserve soft tissue, simplify operative procedure and decrease wound, obtain rigid internal fixation and guarantee early function exercises of ankle joint. In this study we evaluated 22 patients treated in Clinical Emergency Hospital Constanta between April 2012 - July 2013 diagnosed with multifragmentary fractures of the distal tibia. This study evaluates the treatment of complex fractures of distal tibia with locked plate after external fixation. There were 17 males and 5 females of mean age 51,7 years (31-68. The mean follow-up period was 14 weeks. (Ranging from 9-16 weeks. All patients were fully weight bearing at 16 weeks (ranging 9-16 weeks showing radiological union. There were no cases of failures of fixation, or rotational misalignment. No significant complication was observed in our patients. MIPO is an effective method of treatment for distal tibial fractures, reduce surgical trauma and maintain a more biologically favorable environment for fracture healing, reducing risks of infection and nonunion.

  9. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract.

    Science.gov (United States)

    Leitner, L; Brückmann, C I; Gilg, M M; Bratschitsch, G; Sadoghi, P; Leithner, A; Radl, R

    2017-01-01

    Purpose . Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods . We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results . A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI) tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion . Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  10. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    L. Leitner

    2017-01-01

    Full Text Available Purpose. Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods. We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results. A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion. Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  11. Osteosynthesis with long volar locking plates for meta- physeal-diaphyseal fractures of the distal radius

    Directory of Open Access Journals (Sweden)

    Gogna Paritosh

    2013-12-01

    Full Text Available 【Abstract】Objective: Metaphyseal-diaphyseal fractures of the distal radius are a major treatment dilemma and orthopaedic surgeons have to pay due consideration to restoration of anatomy of distal radius together with ro- tation of the radial shaft and maintenance of radial bow and interosseous space. We performed this study to evaluate the clinic-radiological outcome of metaphyseal-diaphyseal fractures of the distal radius treated with long volar locking plates. Methods: This prospective study involved 27 pa- tients (22 males and 5 females with metaphyseal-diaphy- seal fracture of the distal radius. Their mean age was (30.12± 11.48 years (range 19-52 years and the follow-up was 26.8 months (range 22-34 months. All patients underwent open reduction and internal fixation with a long volar locking plate. According to AO/OTA classification, there were 7 type A3, 13 type C2 and 7 type C3 fractures. Subjective assessment was done based on the disabilities of the arm, shoulder and hand (DASH questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist and the radiological determinants included radial angle, radial length, volar angle and ulnar variance. The final as- sessment was done according to Gartland and Werley scor- ing system. Results: Postoperative radiological parameters were well maintained throughout the trial, and there was signifi- cant improvement in the functional parameters from 6 weeks to final follow-up. The average DASH scores improved from 37.5 at 6 weeks to 4.2 at final follow-up. Final assessment using Gartland and Werley scoring system revealed 66.67% (n=18 excellent and 33.33% (n=9 good results. There was one case of superficial infection which responded to antibi- otics and another carpel tunnel syndrome which was ma- naged conservatively. Conclusion: Volar locking plate fixation for metaphy- seal-diaphyseal fractures of distal radius is associated with excellent to good

  12. The applicability of PEEK-based abutment screws.

    Science.gov (United States)

    Schwitalla, Andreas Dominik; Abou-Emara, Mohamed; Zimmermann, Tycho; Spintig, Tobias; Beuer, Florian; Lackmann, Justus; Müller, Wolf-Dieter

    2016-10-01

    The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to its similar elasticity. Also in case of abutment screw fracture, a screw of PEEK could be removed more easily. M1.6-abutment screws of four different PEEK compounds were subjected to tensile tests to set their maximum tensile strengths in relation to an equivalent stress of 186MPa, which is aused by a tightening torque of 15Ncm. Two screw types were manufactured via injection molding and contained 15% short carbon fibers (sCF-15) and 40% (sCF-40), respectively. Two screw types were manufactured via milling and contained 20% TiO2 powder (TiO2-20) and >50% parallel orientated, continuous carbon fibers (cCF-50). A conventional abutments screw of Ti6Al4V (Ti; CAMLOG(®) abutment screw, CAMLOG, Wimsheim, Germany) served as control. The maximum tensile strength was 76.08±5.50MPa for TiO2-20, 152.67±15.83MPa for sCF-15, 157.29±20.11MPa for sCF-40 and 191.69±36.33MPa for cCF-50. The maximum tensile strength of the Ti-screws amounted 1196.29±21.4MPa. The results of the TiO2-20 and the Ti screws were significantly different from the results of the other samples, respectively. For the manufacturing of PEEK abutment screws, PEEK reinforced by >50% continuous carbon fibers would be the material of choice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Resorbable triangular plate for osteosynthesis of fractures of the condylar neck.

    Science.gov (United States)

    Lauer, Günter; Pradel, Winnie; Leonhardt, Henry; Loukota, Richard; Eckelt, Uwe

    2010-10-01

    We describe a new design of resorbable plate for use in the treatment of fractures of the condylar neck, and report the outcome of initial treatment in two patients. Copyright © 2009 The British Association of Oral and Maxillofacial Surgeons. All rights reserved.

  14. Morphology Analysis of Cu Film Fractures in Sandwiched Methylmethacrylate Plates

    Directory of Open Access Journals (Sweden)

    Cristiano Fidani

    2015-06-01

    Full Text Available Thin films of Cu were evaporated on solid plates of polymethylmethacrylate (PMMA. A polymerization process was made to realize sandwiched structure to protect the Cu films. Fracturing of the metal film surface was observed with several morphologies showing two different fracture systems. Surface film morphology was analysed in terms of the distribution area of the islands and contour fractal dimension. The island areas showed a maximum corresponding to 42 nm of the Cu thickness, it was also the threshold to observe the second fracture system. The fractures pattern resulted to be scale invariant with fractal dimensions between 1.55 and 1.7. The minimum fractal dimension also occurred at the film thickness corresponding to the maximum island area. The reported effects can be understood on the basis of different thermal expansion coefficients of the two materials and their thermally induced adhesion.DOI: http://dx.doi.org/10.5755/j01.ms.21.2.6518

  15. Recurrent Laryngeal Edema Imitating Angioedema Caused by Dislocated Screw after Anterior Spine Surgery

    Directory of Open Access Journals (Sweden)

    Piotr Wójtowicz

    2015-01-01

    Full Text Available The anterior cervical spine surgery is a common procedure to stabilize vertebrae damaged by various diseases. The plates and screws are usually used in the spine fixation. This kind of instrumentation may detach from the bones which is a rare but well-known complication. A 77-year-old male presented to the otorhinolaryngology department with throat pain, choking, and dysphagia. At first the angioedema was diagnosed and he was treated conservatively. The endoscopy revealed laryngeal edema, being more defined on the right side with right vocal fold paresis. CT scans showed the stabilizing plate with two screws attached tightly and the back-out of the third screw toward soft tissue of the neck. In the meantime, his condition deteriorated and he needed tracheotomy. In few days the surgical removal of the dislocated screw was performed successfully. Although two-month follow-up reported no obstruction of the larynx, the vocal folds paresis with gradual functional improvement was observed. Long-term complication of anterior spine surgery sometimes may suggest laryngeal angioedema at first. If the conservative treatment is ineffective and there is a history of anterior spine surgery, the clinicians should consider the displacement of the plate or screws in differential diagnosis.

  16. Biomechanical investigation of an alternative concept to angular stable plating using conventional fixation hardware

    Directory of Open Access Journals (Sweden)

    Radtke Roman

    2010-05-01

    Full Text Available Abstract Background Angle-stable locking plates have improved the surgical management of fractures. However, locking implants are costly and removal can be difficult. The aim of this in vitro study was to evaluate the biomechanical performance of a newly proposed crossed-screw concept ("Fence" utilizing conventional (non-locked implants in comparison to conventional LC-DCP (limited contact dynamic compression plate and LCP (locking compression plate stabilization, in a human cadaveric diaphyseal gap model. Methods In eight pairs of human cadaveric femora, one femur per pair was randomly assigned to receive a Fence construct with either elevated or non-elevated plate, while the contralateral femur received either an LCP or LC-DCP instrumentation. Fracture gap motion and fatigue performance under cyclic loading was evaluated successively in axial compression and in torsion. Results were statistically compared in a pairwise setting. Results The elevated Fence constructs allowed significantly higher gap motion compared to the LCP instrumentations (axial compression: p ≤ 0.011, torsion p ≤ 0.015 but revealed similar performance under cyclic loading (p = 0.43. The Fence instrumentation with established bone-plate contact revealed larger fracture gap motion under axial compression compared to the conventional LC-DCP osteosynthesis (p ≤ 0.017. However, all contact Fence specimens survived the cyclic test, whereas all LC-DCP constructs failed early during torsion testing (p Conclusions Even though accentuated fracture gap motion became obvious, the "Fence" technique is considered an alternative to cost-intensive locking-head devices. The concept can be of interest in cases were angle-stable implants are unavailable and can lead to new strategies in implant design.

  17. Do intramedullary implants improve survival in elderly patients with trochanteric fractures? A retrospective study.

    Science.gov (United States)

    Vermesan, D; Prejbeanu, R; Poenaru, D V; Petrescu, H; Apostol, E; Inchingolo, F; Dipalma, G; Abbinante, A; Caprio, M; Potenza, M A; Cagiano, R; Malcangi, G; Inchingolo, A D; Haragus, H

    2015-01-01

    There is currently no consensus regarding superiority of the intramedullary fixation over the sliding hip screw. Regional variation remains high and not backed up by solid evidence. Given these premises we aimed to analyze weather implant preference can influence the postoperative survival. Secondary objectives were determining the trend for implant choice and confounding factors associated with intramedullary nails compared to sliding hip screws. Retrospective data was obtained from patient charts with the main diagnosis of extracapsular/ trochanteric fractures, corresponding to ICD S72.1 codes. Between 2008-2012, 441 patients underwent osteosynthesis with a dynamic hip screw and 155 with intramedullary nail respectively. The living status was determined by comparing the patient identification number against the national population evidence records. The lifetable shows similar survival for both implants over the 5 year period. The yearly mortality was 19.4% for the dynamic hip screw and 21.8% for the intramedullary implant respectively, even though the later were used predominantly in older patients. This age difference is significant according to both parametric and non-parametric tests whereas duration of hospital stay are similar. We found a clear increase in the proportion of intramedullary implants, for a total of 11.2% over the 5 year period. There is no difference for the one year mortality and overall survival between sliding screw plates and intramedullary constructs. A clear increase in the use of intramedullary implants for trochanteric fractures was observed. This is even more apparent for older ages, presumably due to an higher surgeon confidence with the biomechanical stability of the intramedullary constructs.

  18. Angular-stable locking plate fixation of tibial plateau fractures-clinical and radiological midterm results in 101 patients

    OpenAIRE

    Sven Mardian; Felix Landmann; Florian Wichlas; Norbert P Haas; Klaus-Dieter Schaser; Philipp Schwabe

    2015-01-01

    Background: Articular reconstruction and stable fixation of tibial plateau fractures and its various subtypes continue to represent a surgical challenge. Only few trials have studied results following angular stable plate fixation. The present study aimed to investigate the clinical, radiological, functional and quality of life results following tibial plateau fractures using angular stable plate fixation. Materials and Methods: 101 patients were retrospectively studied using functional (...

  19. A novel combined method of osteosynthesis in treatment of tibial fractures: a comparative study on sheep with application of rod-through-plate fixator and bone plating.

    Science.gov (United States)

    Tralman, G; Andrianov, V; Arend, A; Männik, P; Kibur, R T; Nõupuu, K; Uksov, D; Aunapuu, M

    2013-04-01

    The study compares the efficiency of a new bone fixator combining periostal and intramedullary osteosynthesis to bone plating in treatment of tibial fractures in sheep. Experimental osteotomies were performed in the middle third of the left tibia. Animals were divided into two groups: in one group (four animals) combined osteosynthesis (rod-through-plate fixator, RTP fixator) was applied, and in the other group (three animals) bone plating was used. The experiments lasted for 10 weeks during which fracture union was followed by radiography, and the healing process was studied by blood serum markers reflecting bone turnover and by histological and immunohistochemical investigations. In the RTP fixator group, animals started to load body weight on the operated limbs the next day after the surgery, while in the bone plating group, this happened only on the seventh day. In the RTP fixator group, consolidation of fractures was also faster, as demonstrated by radiographical, histological, and immunohistochemical investigations and in part by blood serum markers for bone formation. It can be concluded that application of RTP fixation is more efficient than plate fixation in the treatment of experimental osteotomies of long bones in sheep. © 2012 Blackwell Verlag GmbH.

  20. Pediatric facial fractures: evolving patterns of treatment.

    Science.gov (United States)

    Posnick, J C; Wells, M; Pron, G E

    1993-08-01

    This study reviews the treatment of facial trauma between October 1986 and December 1990 at a major pediatric referral center. The mechanism of injury, location and pattern of facial fractures, pattern of facial injury, soft tissue injuries, and any associated injuries to other organ systems were recorded, and fracture management and perioperative complications reviewed. The study population consisted of 137 patients who sustained 318 facial fractures. Eighty-one patients (171 fractures) were seen in the acute stage, and 56 patients (147 fractures) were seen for reconstruction of a secondary deformity. Injuries in boys were more prevalent than in girls (63% versus 37%), and the 6- to 12-year cohort made up the largest group (42%). Most fractures resulted from traffic-related accidents (50%), falls (23%), or sports-related injuries (15%). Mandibular (34%) and orbital fractures (23%) predominated; fewer midfacial fractures (7%) were sustained than would be expected in a similar adult population. Three quarters of the patients with acute fractures required operative intervention. Closed reduction techniques with maxillomandibular fixation were frequently chosen for mandibular condyle fractures and open reduction techniques (35%) for other regions of the facial skeleton. When open reduction was indicated, plate-and-screw fixation was the preferred method of stabilization (65%). The long-term effects of the injuries and the treatment given on facial growth remain undetermined. Perioperative complication rates directly related to the surgery were low.

  1. Comparison of apical extrusion of intracanal bacteria by various glide-path establishing systems: an in vitro study

    Directory of Open Access Journals (Sweden)

    Alberto Dagna

    2017-11-01

    Full Text Available Objectives This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi rotary systems. Materials and Methods Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G. At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU. Results The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups (p < 0.05. The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. Conclusions All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.

  2. Treatment of Middle Third Humeral Shaft Fractures with Anteromedial Plate Osteosynthesis through an Anterolateral Approach

    Directory of Open Access Journals (Sweden)

    Kumar BS

    2016-03-01

    Full Text Available Background: Treatment of humeral shaft fractures has been a subject of debate for many decades. Even though a large majority of humeral shaft fractures can be treated by non operative methods, few conditions like open fractures, polytrauma, ipsilateral humeral shaft and forearm fractures require surgical intervention. The goal of treatment of humeral shaft fractures is to establish union with an acceptable humeral alignment and to restore the patient to pre-injury level of function. The objective was to assess the incidence of radial nerve palsy, non-union and mean time required for in anteromedial plate osteosynthesis with anterolateral approach and also to measure the functional outcome of this procedure. Method: A prospective study was conducted in the Department of Orthopaedics, PESIMSR, Kuppam, Andhra Pradesh, from August 2012 to August 2015 with a total of 54 patients who were operated with anteromedial plate osteosynthesis were included in the study. RodriguezMerchan criteria was used to grade the functional outcome. Results: Of the 54 patients, 28 (58.85% were in the age group of 30-40 years. The most common fracture pattern identified was A3 type (48.14%.The mean (+ SD duration of surgery for anteromedial humeral plating was 53 ± 5.00 minutes. The time taken for the fracture to unite was less than 16 weeks in the majority or 50 patients (92.59%. Four (7.40% patients had delayed union. There was no incidence of iatrogenic radial nerve palsy. Rodriguez – Merchan criteria showed that 37(68.51% of the patients had good and 12 (22.22% had excellent functional outcome.

  3. A clinical evaluation of alternative fixation techniques for medial malleolus fractures.

    Science.gov (United States)

    Barnes, Hayley; Cannada, Lisa K; Watson, J Tracy

    2014-09-01

    Medial malleolus fractures have traditionally been managed using partially threaded screws and/or Kirschner wire fixation. Using these conventional techniques, a non-union rate of as high as 20% has been reported. In addition too many patients complaining of prominent hardware as a source of pain post-fixation. This study was designed to assess the outcomes of medial malleolar fixation using a headless compression screw in terms of union rate, the need for hardware removal, and pain over the hardware site. Saint Louis University and Mercy Medical Center, Level 1 Trauma Centers, St. Louis, MO. After IRB approval, we used billing records to identify all patients with ankle fractures involving the medial malleolus. Medical records and radiographs were reviewed to identify patients with medial malleolar fractures treated with headless compression screw fixation. Our inclusion criteria included follow-up until full weight bearing and a healed fracture. Follow-up clinical records and radiographs were reviewed to determine union, complication rate and perception of pain over the site of medial malleolus fixation. Sixty-four ankles were fixed via headless compression screws and 44 had adequate follow-up for additional evaluation. Seven patients had isolated medial malleolar fractures, 23 patients had bimalleolar fractures, and 14 patients had trimalleolar fractures. One patient (2%) required hardware removal due to cellulitis. One patient (2%) had a delayed union, which healed without additional intervention. Ten patients (23%) reported mild discomfort to palpation over the medial malleolus. The median follow-up was 35 weeks (range: 12-208 weeks). There were no screw removals for painful hardware and no cases of non-union. Headless compression screws provide effective compression of medial malleolus fractures and result in good clinical outcomes. The headless compression screw is a beneficial alternative to the conventional methods of medial malleolus fixation. Copyright

  4. Treatment Results Of Diaphyseal Forearm Fractures With Dynamique Compression Plate A Retrospective study of 156 Cases.

    Directory of Open Access Journals (Sweden)

    Hassan BOUSSAKRI

    2015-12-01

    Full Text Available This retrospective study addresses a series of 156 cases of forearm fractures. These 156 cases were managed in the trauma-orthopedic department (B4 of Fez University Hospital, Morocco, from May 2008 till January 2013. The purpose of this study is to analyze epidemiological and clinical factors of diaphyseal forearm fractures and the results of their treatment with dynamic compression plate (DCP, as well as the complications and therapeutic errors of this surgical technique. The frequency of hospitalization in the trauma-orthopedic department was 3,96%. Ages ranged between 16 and 83, the average age was 32. 132 patients were male (85%. 90% were managed at the day of trauma. Traffic accidents were the most frequent cause in 52% patients. The fracture was in the left forearm in 65% of patients. 53% of fracture lines were in the middle third of the forearm. 38 fractures were open, and 30 were admitted for polytrauma. Osteosynthesis was performed with dynamic compression plate for all patients. In comparison with the literature, our series shows the predominance of young male patients, with traffic accidents being the cause. Osteosynthesis with dynamic compression plate remains the treatment of choice that provides satisfactory results if the accuracy in this technique was respected.

  5. Locking plate osteosynthesis in displaced 4-part fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig; Frich, Lars H; Winther, Annika

    2011-01-01

    There is considerable uncertainty about the optimal treatment of displaced 4-part fractures of the proximal humerus. Within the last decade, locking plate technology has been considered a breakthrough in the treatment of these complex injuries....

  6. Fractures of the proximal fifth metatarsal: percutaneous bicortical fixation.

    Science.gov (United States)

    Mahajan, Vivek; Chung, Hyun Wook; Suh, Jin Soo

    2011-06-01

    Displaced intraarticular zone I and displaced zone II fractures of the proximal fifth metatarsal bone are frequently complicated by delayed nonunion due to a vascular watershed. Many complications have been reported with the commonly used intramedullary screw fixation for these fractures. The optimal surgical procedure for these fractures has not been determined. All these observations led us to evaluate the effectiveness of percutaneous bicortical screw fixation for treating these fractures. Twenty-three fractures were operatively treated by bicortical screw fixation. All the fractures were evaluated both clinically and radiologically for the healing. All the patients were followed at 2 or 3 week intervals till fracture union. The patients were followed for an average of 22.5 months. Twenty-three fractures healed uneventfully following bicortical fixation, with a mean healing time of 6.3 weeks (range, 4 to 10 weeks). The average American Orthopaedic Foot & Ankle Society (AOFAS) score was 94 (range, 90 to 99). All the patients reported no pain at rest or during athletic activity. We removed the implant in all cases at a mean of 23.2 weeks (range, 18 to 32 weeks). There was no refracture in any of our cases. The current study shows the effectiveness of bicortical screw fixation for displaced intraarticular zone I fractures and displaced zone II fractures. We recommend it as one of the useful techniques for fixation of displaced zone I and II fractures.

  7. Using external and internal locking plates in a two-stage protocol for treatment of segmental tibial fractures.

    Science.gov (United States)

    Ma, Ching-Hou; Tu, Yuan-Kun; Yeh, Jih-Hsi; Yang, Shih-Chieh; Wu, Chin-Hsien

    2011-09-01

    The tibial segmental fractures usually follow high-energy trauma and are often associated with many complications. We designed a two-stage protocol for these complex injuries. The aim of this study was to assess the outcome of tibial segmental fractures treated according to this protocol. A prospective series of 25 consecutive segmental tibial fractures were treated using a two-stage procedure. In the first stage, a low-profile locking plate was applied as an external fixator to temporarily immobilize the fractures after anatomic reduction had been achieved followed by soft-tissue reconstruction. The second stage involved definitive internal fixation with a locking plate using a minimally invasive percutaneous plate osteosynthesis technique. The median follow-up was 32 months (range, 20-44 months). All fractures achieved union. The median time for the proximal fracture union was 23 weeks (range, 12-30 weeks) and that for distal fracture union was 27 weeks (range, 12-46 weeks; p = 0.08). Functional results were excellent in 21 patients and good in 4 patients. There were three cases of delayed union of distal fracture. Valgus malunion >5 degrees occurred in two patients, and length discrepancy >1 cm was observed in two patients. Pin tract infection occurred in three patients. Use of the two-stage procedure for treatment of segmental tibial fractures is recommended. Surgeons can achieve good reduction with stable temporary fixation, soft-tissue reconstruction, ease of subsequent definitive fixation, and high union rates. Our patients obtained excellent knee and ankle joint motion, good functional outcomes, and a comfortable clinical course.

  8. Comparison of the results of wide plate tests with the predictions of several fracture concepts

    International Nuclear Information System (INIS)

    Rosezin, H.J.; Dahl, W.

    1985-01-01

    With the results of wide plate tests on center cracked specimens the concept of the plastic limit load, the Burdekin-Dawes-design-concept, the J-design-curve according to Turner, the estimation proceeding according to Shih and Kumar, the Two-Criteria-Approach and the FAD according to Pellini were examined and the limits of their application exhibited. The maximum loads of wide plate specimens can be estimated by the plastic limit load, if no low-stress-fractures occur. Corresponding to the Pellini-concept no low-stress-fractures occured at test temperatures above NDT, if the NDT-temperature of the region of material was used, in which the crack was located. With the concept according to Shih and Kumar an estimation of the instability loads of wide plate specimens is possible, if the fracture behaviour is fully ductile, but not in all cases conservative predictions were made. A prediction of critical stresses and crack sizes is possible with the other concepts examined, if the evaluations are based on the critical values for the onset of stable or unstable crack growth. (orig.) [de

  9. Pediatric maxillary fractures.

    Science.gov (United States)

    Yu, Jack; Dinsmore, Robert; Mar, Philip; Bhatt, Kirit

    2011-07-01

    Pediatric craniofacial structures differ from those of adults in many ways. Because of these differences, management of pediatric craniofacial fractures is not the same as those in adults. The most important differences that have clinical relevance are the mechanical properties, craniofacial anatomy, healing capacity, and dental morphology. This article will review these key differences and the management of pediatric maxillary fractures. From the mechanical properties' perspective, pediatric bones are much more resilient than adult bones; as such, they undergo plastic deformation and ductile failure. From the gross anatomic perspective, the relative proportion of the cranial to facial structures is much larger for the pediatric patients and the sinuses are not yet developed. The differences related to dentition and dental development are more conical crowns, larger interdental spaces, and presence of permanent tooth buds in the pediatric population. The fracture pattern, as a result of all the above, does not follow the classic Le Fort types. The maxillomandibular fixation may require circum-mandibular wires, drop wires, or Ivy loops. Interfragmentary ligatures using absorbable sutures play a much greater role in these patients. The use of plates and screws should take into consideration the future development with respect to growth centers and the location of the permanent tooth buds. Pediatric maxillary fractures are not common, require different treatments, and enjoy better long-term outcomes.

  10. Functional outcome of Schatzker type V and VI tibial plateau fractures treated with dual plates

    Directory of Open Access Journals (Sweden)

    G Thiruvengita Prasad

    2013-01-01

    Full Text Available Background: Dual plate fixation in comminuted bicondylar tibial plateau fractures remains controversial. Open reduction and internal fixation, specifically through compromised soft tissues, has historically been associated with major wound complications. Alternate methods of treatment have been described, each with its own merits and demerits. We performed a retrospective study to evaluate the functional outcome of lateral and medial plate fixation of Schatzker type V and VI fractures through an anterolateral approach, and a medial minimally invasive approach or a posteromedial approach. Materials and Methods: We treated 46 tibial plateau fractures Schatzker type V and VI with lateral and medial plates through an anterolateral approach and a medial minimal invasive approach over an 8 years period. Six patients were lost to followup. Radiographs in two planes were taken in all cases. Immediate postoperative radiographs were assessed for quality of reduction and fixation. The functional outcome was evaluated according to the Oxford Knee Score criteria on followup. Results: Forty patients (33 men and 7 women who completed the followup were included in the study. There were 20 Schatzker type V fractures and 20 Schatzker type VI fractures. The mean duration of followup was 4 years (range 1-8 years. All patients had a satisfactory articular reduction defined as ≤2 mm step-off or gap as assessed on followup. All patients had a good coronal and sagittal plane alignment, and articular width as assessed on supine X-rays of the knee in the anteroposterior (AP and lateral views. The functional outcome, as assessed by the Oxford Knee Score, was excellent in 30 patients and good in 10 patients. All patients returned to their pre-injury level of activity and employment. There were no instances of deep infection. Conclusions: Dual plate fixation of severe bicondylar tibial plateau fractures is an excellent treatment option as it provides rigid fixation and

  11. Underlying and derived glides in Middle High German

    Directory of Open Access Journals (Sweden)

    Tracy Alan Hall

    2017-05-01

    Full Text Available The present study investigates the phonology of glides in Middle High German. On the basis of surface contrasts between prevocalic nuclear glides in syllable-final position ([VG.V] and postvocalic glides in onset position ([V.GV], it is argued that the latter were underlying glides (e.g. the /w/ in [le.wə] ‘lion’ and that the former were glides derived from vowels (e.g. the offglide [o̯] in the diphthong [uo̯] from /uo/. Underlying glides are argued to be [+consonantal], while nuclear glides ‒ like the vowels from which they derive ‒ are [‒consonantal]. The analysis of Middle High German bears on several debates involving glides in the theoretical literature. First, a treatment with an underlying glide in /VGV/ cannot be reanalyzed by treating the vowels as peaks (e.g. Harris & Kaisse 1999 for Argentinian Spanish. Second, the treatment of underlying glides as [+consonantal] is to be preferred over alternatives which analyze those sounds as [‒vocalic] (e.g. Nevins & Chitoran 2008 for several languages. Third, an analysis of nuclear structure is adopted (from Harris & Kaisse 1999 which enables one to interpret which element in a complex nucleus is the peak and which is the nonpeak without stipulation. Fourth, the contrastive syllabification of surface glides (i.e. [VG.V] vs. [V.GV] is shown to be a diagnostic of underlying glide languages that has not been discussed in the literature to date.

  12. MINIMAL INVASIVE PLATE OSTEOSYNTHESIS- AN EFFECTIVE TREATMENT METHOD FOR DISTAL TIBIA INTRAARTICULAR (PILON FRACTURES- AN 18 MONTHS FOLLOW UP

    Directory of Open Access Journals (Sweden)

    Saket Jati

    2016-12-01

    Full Text Available BACKGROUND Tibial pilon fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable, because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and Minimally Invasive Plate Osteosynthesis (MIPO for distal tibia has emerged as an alternative treatment option because it respects fracture biology and haematoma and also provides biomechanically stable construct. The aim of the study is to evaluate the results of minimally invasive plate osteosynthesis using locking plates in treating tibial pilon fractures in terms of fracture union, restoration of ankle function and complications. MATERIALS AND METHODS 30 patients with closed tibial pilon fractures (Ruedi and Allgower type I (14, type II (13, type III (3 treated with MIPO with Locking Compression Plates (LCP were prospectively followed for average duration of 18 months. RESULTS Average duration of injury-hospital and injury-surgery interval was as 12.05 hrs. and 3.50 days, respectively. All fractures got united with an average duration of 20.8 weeks (range 14-28 weeks. Olerud and Molander score was used for evaluation at 3 months, 6 months and 18 months. One patient had union with valgus angulation of 15 degrees, but no nonunion was found. CONCLUSION The present study shows that MIPO with LCP is an effective treatment method in terms of union time and complications rate for tibial pilon fracture promoting early union and early weight bearing.

  13. Results of fracture mechanics tests on PNC SUS 304 plate

    International Nuclear Information System (INIS)

    Mills, W.J.; James, L.A.; Blackburn, L.D.

    1985-08-01

    PNC provided SUS 304 plate to be irradiated in FFTF at about 400 0 C to a target fluence of 5 x 10 21 n/cm 2 (E > 0.1 MeV). The actual irradiation included two basically different exposure levels to assure that information would be available for the exposure of interest. After irradiation, tensile properties, fatigue-crack growth rates and J-integral fracture toughness response were determined. These same properties were also measured for the unirradiated material so radiation damage effects could be characterized. This report presents the results of this program. It is expected that these results would be applicable for detailed fracture analysis of reactor components. Recent advances in elastic-plastic fracture mechanics enable reasonably accurate predictions of failure conditions for flawed stainless steel components. Extensive research has focused on the development of J-integral-based engineering approach for assessing the load carrying capacity of low-strength, high-toughness structural materials. Furthermore, Kanninen, et al., have demonstrated that J-integral concepts can accurately predict the fracture response for full-scale cracked structures manufactured from Type 304 stainless steel

  14. Calcaneal Fractures in Non-Racing Dogs and Cats: Complications, Outcome, and Associated Risk Factors.

    Science.gov (United States)

    Perry, Karen L; Adams, Robert J; Woods, Samantha; Bruce, Mieghan

    2017-01-01

    To estimate the prevalence of complications and describe the outcome associated with calcaneal fractures in non-racing dogs and in cats. Retrospective multicenter clinical cohort study. Medical records of client-owned dogs and cats (2004-2013). Medical records were searched and 50 animals with calcaneal fractures were included for analysis. Complications were recorded and an outcome score applied to each fracture. Associations between putative risk factors and both major complications, and final outcome scores were explored. Complications occurred in 27/50 fractures (61%) including 23 major and 4 minor complications. At final follow-up, 4 animals (10%) were sound, 27 (64%) had either intermittent or consistent mild weight-bearing lameness, 7 (17%) had moderate weight-bearing lameness, and 1 (2%) had severe weight-bearing lameness. Fractures managed using plates and screws had a lower risk of complications than fractures managed using pin and tension band wire, lag or positional screws or a combination of these techniques (Relative risk 0.16, 95% CI 0.02-1.02, P=.052). Non-sighthounds had reduced odds of a poorer outcome score than sighthounds (Odds ratio 0.11, 95% CI 0.02-0.50, P=.005) and fractures with major complications had 13 times the odds of a poorer outcome score (Odds ratio 13.4, 95% CI 3.6-59.5, Pdogs and in cats, and a poorer outcome score was more likely in animals with complications. A more guarded prognosis should be given to owners of non-racing dogs or cats with calcaneal fractures than previously applied to racing Greyhounds with calcaneal fractures. © 2016 The American College of Veterinary Surgeons.

  15. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    Directory of Open Access Journals (Sweden)

    Tabet A. Al-Sadek

    2016-11-01

    Full Text Available BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with

  16. Use of rectangular grid miniplates for fracture fixation at the mandibular angle.

    Science.gov (United States)

    Hochuli-Vieira, Eduardo; Ha, Thi Khanh Linh; Pereira-Filho, Valfrido Antonio; Landes, Constantin Alexander

    2011-05-01

    The aim of this study was to evaluate the clinical outcome of patients with mandibular angle fractures treated by intraoral access and a rectangular grid miniplate with 4 holes and stabilized with monocortical screws. This study included 45 patients with mandibular angle fractures from the Department of Oral and Maxillofacial Surgery São Paulo State University, Araraquara, Brazil, and from the Clinic of Oral and Maxillofacial Surgery at the University of Frankfurt, Germany. The 45 fractures of the mandibular angle were treated with a rectangular grid miniplate of a 2.0-mm system by an intraoral approach with monocortical screws. Clinical evaluations were postoperatively performed at 15 and 30 days and 3 and 6 months, and the complications encountered were recorded and treated. The infection rate was 4.44% (2 patients), and in 1 patient it was necessary to replace hardware. This patient also had a fracture of the left mandibular body; 3 patients (6.66%) had minor occlusal changes that have been resolved with small occlusal adjustments. Before surgery, 15 patients (33.33%) presented with hypoesthesia of the inferior alveolar nerve; 4 (8.88%) had this change until the last clinical control, at 6 months. The rectangular grid miniplate used in this study was stable for the treatment of simple mandibular angle fractures through intraoral access, with low complication rates, easy handling, and easy adjustment, with a low cost. Concomitant mandibular fracture may increase the rate of complications. This plate should be indicated in fractures with sufficient interfragmentary contact. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?

    Science.gov (United States)

    Concha, Juan M; Sandoval, Alejandro; Streubel, Philipp N

    2010-12-01

    Minimally invasive plate osteosynthesis (MIPO) has been advocated as a safe approach to humeral shaft fracture management. We evaluated the reproducibility of this technique in a regional hospital. Thirty-five patients underwent MIPO of humerus shaft fractures. Fifteen patients had an open fracture, six a preoperative radial nerve palsy, and nine a concomitant thoracic, musculoskeletal or vascular injury. At an average 12-month follow-up, 91% of fractures healed after a mean of 12 weeks (range, 8-16). Two infections occurred. Final alignment averaged 4° of varus (range, 5° of valgus to 20° of varus). Active elbow ROM averaged 114° (range, 60-135°) and was less than 100° in nine elbows. Five of six preoperative radial nerve injuries recovered spontaneously. Healing and infection rates in this study are consistent with those reported in the literature. Lower elbow ROM and higher fracture angulation at healing were nevertheless found. MIPO is technically demanding and requires adequate intraoperative imaging and surgical experience in order to obtain adequate fracture alignment. Brachialis muscle scarring and inadequate postoperative rehabilitation may be involved in limited elbow range of motion.

  18. Use of locking compression plates in ulnar fractures of 18 horses.

    Science.gov (United States)

    Jacobs, Carrie C; Levine, David G; Richardson, Dean W

    2017-02-01

    To describe the outcome, clinical findings, and complications associated with the use of the locking compression plate (LCP) for various types of ulnar fractures in horses. Retrospective case series. Client owned horses (n = 18). Medical records, radiographs, and follow-up for horses having an ulnar fracture repaired using at least 1 LCP were reviewed. Fifteen of 18 horses had fractures of the ulna only, and 3 horses had fractures of the ulna and proximal radius. All 18 horses were discharged from the hospital. Complications occurred in 5 horses; incisional infection (n = 4, 22%), implant-associated infection (n = 2, 11%), and colic (n = 1, 6%). Follow-up was available for all horses at a range of 13-120 months and 15 horses (83%) were sound for their intended purpose and 3 horses (17%) were euthanatized. One horse was euthanatized for complications associated with original injury and surgery. The LCP is a viable method of internal fixation for various types of ulnar fractures, with most horses in this series returning to soundness. © 2017 The American College of Veterinary Surgeons.

  19. Alternative technique of cervical spinal stabilization employing lateral mass plate and screw and intra-articular spacer fixation

    Directory of Open Access Journals (Sweden)

    Atul Goel

    2013-01-01

    Full Text Available Aim: The author discusses an alternative technique of segmental cervical spinal fixation. Material and Methods: The subtleties of the technique are discussed on the basis of experience with 3 cases with a follow-up of between 30 and 36 months. Technique: The technique involves debridement of facetal articular cartilage, distraction of facets, jamming of ′Goel spacer′ into the articular cavity and fortification of the fixation by lateral mass plate and screw fixation. The ′double-insurance′ method of fixation is safe for vertebral artery, nerve roots and spinal neural structures and the fixation is strong. Conclusions: The discussed technique is safe and provides a strong fixation and a ground for ultimate arthrodesis.

  20. Direct prediction of the solute softening-to-hardening transition in W–Re alloys using stochastic simulations of screw dislocation motion

    Science.gov (United States)

    Zhao, Yue; Marian, Jaime

    2018-06-01

    Interactions among dislocations and solute atoms are the basis of several important processes in metal plasticity. In body-centered cubic (bcc) metals and alloys, low-temperature plastic flow is controlled by screw dislocation glide, which is known to take place by the nucleation and sideward relaxation of kink pairs across two consecutive Peierls valleys. In alloys, dislocations and solutes affect each other’s kinetics via long-range stress field coupling and short-range inelastic interactions. It is known that in certain substitutional bcc alloys a transition from solute softening to solute hardening is observed at a critical concentration. In this paper, we develop a kinetic Monte Carlo model of screw dislocation glide and solute diffusion in substitutional W–Re alloys. We find that dislocation kinetics is governed by two competing mechanisms. At low solute concentrations, nucleation is enhanced by the softening of the Peierls stress, which dominates over the elastic repulsion of Re atoms on kinks. This trend is reversed at higher concentrations, resulting in a minimum in the flow stress that is concentration and temperature dependent. This minimum marks the transition from solute softening to hardening, which is found to be in reasonable agreement with experiments.