WorldWideScience

Sample records for fracture intraoperatively case

  1. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    Science.gov (United States)

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  2. A minimally invasive treatment for zygomatic fracture with intraoperative assessment using ultrasonography

    International Nuclear Information System (INIS)

    Soejima, Kazutaka; Sakurai, Hiroyuki; Nozaki, Motohiro; Kitazawa, Yoshihiko; Takeuchi, Masaki; Yamaki, Takashi; Kohno, Taro; Fujiwara, Osamu

    2006-01-01

    In the department of plastic and reconstructive surgery of Tokyo Women's Medical University and Tokyo Metropolitan Hiroo General Hospital, twenty-one patients with zygomatic fracture were surgically treated by semi-closed reduction with intraoperative assessment using ultrasonography in the period of April, 2002 to December, 2005. Ultrasonic imaging was carried out at three areas: the infraorbital rim, the zygomatic arch and the frontal wall of maxilla. Only one skin incision was made and that was at the lateral eyebrow region and the reduction was performed by inserting an elevator beneath the zygomatic arch. Just after the reduction, the ultrasound examination was performed intraoperatively and the bone alignment was assessed. When the reduction was accurate, the zygomatic-frontal suture was fixated with a micro-plate and zygoma-to-zygoma pinning with Kirshner wire was performed. In all cases, accurate reduction was obtained. In 5 of the 21 cases, the Digital Imaging and Communications in Medicine (DICOM) data of the CT was analyzed with 3D imaging software (V-works, CyberMed Co., Korea). The results revealed that post-operative movement of the bone fragment was minimal. The current study suggests that a semi-closed reduction of zygomatic fracture with intraoperative assessment using ultrasonography could be an alternative minimally invasive method'' for the treatment of the zygomatic fracture. (author)

  3. Orbital Floor Fracture with Atypical Extraocular Muscle Entrapment Pattern and Intraoperative Asystole in an Adult

    Science.gov (United States)

    Merali, Farhan I.; Grant, Michael P.; Mahoney, Nicholas R.

    2015-01-01

    Extraocular muscle entrapment in a nondisplaced orbital fracture, although a well-known entity in pediatric trauma, is atypical in adults. It can present with a triad of bradycardia, nausea, and in rare cases, syncope, and result in severe fibrosis of damaged and incarcerated muscle. We present a case of muscle entrapment in a partially nondisplaced two-wall orbital fracture with accompanying preoperative bradycardia and intraoperative asystole in an adult PMID:26576246

  4. Intramedullary nailing of proximal and distal one-third tibial shaft fractures with intraoperative two-pin external fixation.

    Science.gov (United States)

    Wysocki, Robert W; Kapotas, James S; Virkus, Walter W

    2009-04-01

    Fractures of the proximal and distal one thirds of the tibial shaft have historically higher malunion rates than those of the midshaft. This retrospective case series evaluates the postoperative radiographic outcome of intramedullary nailing of proximal and distal one-third tibial shaft fractures using intraoperative two-pin external fixation, often referred to as traveling traction. Between 2000 and 2005, 15 consecutive patients with proximal third and 27 consecutive patients with distal third displaced extra-articular fractures of the tibia were treated with statically locked intramedullary nailing and supplementary intraoperative two-pin rectangular frame external fixation. The external fixation was removed once the proximal and distal locking screws were in place. The alignment of the fractures was determined using standard postoperative anteroposterior and lateral radiographs. Postoperatively, 14 of 15 patients with proximal fractures and 25 of 27 patients with distal fractures had less than 5 degrees of angular deformity in both the coronal and sagittal planes and less than 1 cm shortening. Statically locked intramedullary nailing with simultaneous intraoperative traveling traction external fixation as treatment for proximal and distal one-third extra-articular tibial shaft fractures is successful in achieving a high rate of acceptable postoperative alignment.

  5. Odontoid fractures: A retrospective analysis of 53 cases

    Directory of Open Access Journals (Sweden)

    Shetty Arjun

    2009-01-01

    Full Text Available Background: The management of odontoid fracture has evolved but controversy persists as to the best method for Type II odontoid fractures with or without atlantoaxial (AA instability. The anterior odontoid screw fixation can be associated with significant morbidity while delayed odontoid screw fixation has shown to be associated with reasonable good fusion rates. We conducted a retrospective analysis to evaluate the outcome of a trial of conservative management in type II odontoid fractures without atlantoaxial instability (Group A followed by delayed odontoid screw fixation in cases in which fusion was not achieved by conservative treatment. The outcome of type II odontoid fracture with AA subluxation (Group B was also analysed where closed reduction on traction could be achieved and in those atlantoaxial subluxations that were irreducible an intraoperative reduction was done. Materials and Methods: A retrospective evaluation of 53 cases of odontoid fractures treated over a 9-year period is being reported. All odontoid fractures without AA instability (n=29 were initially managed conservatively. Three patients who did not achieve union with conservative management were treated with delayed anterior screw fixation. Twenty-four cases of odontoid fractures were associated with AA instability; 17 of them could be reduced with skeletal traction and were managed with posterior fusion and fixation. Of the seven cases that were irreducible, the initial three cases were treated by odontoid excision followed by posterior fusion and fixation; however, in the later four cases, intra operative reduction was achieved by a manipulation procedure, and posterior fusion and fixation was performed. Results: Twenty-six of 29 cases of odontoid fracture without AA instability achieved fracture union with conservative management whereas the remaining three patients achieved union following delayed anterior odontoid screw fixation. 17 out of 24 odontoid fracture with

  6. Intra-operative 3D imaging system for robot-assisted fracture manipulation.

    Science.gov (United States)

    Dagnino, G; Georgilas, I; Tarassoli, P; Atkins, R; Dogramadzi, S

    2015-01-01

    Reduction is a crucial step in the treatment of broken bones. Achieving precise anatomical alignment of bone fragments is essential for a good fast healing process. Percutaneous techniques are associated with faster recovery time and lower infection risk. However, deducing intra-operatively the desired reduction position is quite challenging due to the currently available technology. The 2D nature of this technology (i.e. the image intensifier) doesn't provide enough information to the surgeon regarding the fracture alignment and rotation, which is actually a three-dimensional problem. This paper describes the design and development of a 3D imaging system for the intra-operative virtual reduction of joint fractures. The proposed imaging system is able to receive and segment CT scan data of the fracture, to generate the 3D models of the bone fragments, and display them on a GUI. A commercial optical tracker was included into the system to track the actual pose of the bone fragments in the physical space, and generate the corresponding pose relations in the virtual environment of the imaging system. The surgeon virtually reduces the fracture in the 3D virtual environment, and a robotic manipulator connected to the fracture through an orthopedic pin executes the physical reductions accordingly. The system is here evaluated through fracture reduction experiments, demonstrating a reduction accuracy of 1.04 ± 0.69 mm (translational RMSE) and 0.89 ± 0.71 ° (rotational RMSE).

  7. Effect of Intraoperative Three-Dimensional Imaging During the Reduction and Fixation of Displaced Calcaneal Fractures on Articular Congruence and Implant Fixation

    DEFF Research Database (Denmark)

    Eckardt, Henrik; Lind, Marianne

    2015-01-01

    BACKGROUND: Operative treatment of displaced calcaneal fractures should restore joint congruence, but conventional fluoroscopy is unable to fully visualize the subtalar joint. We questioned whether intraoperative 3-dimensional (3D) imaging would aid in the reduction of calcaneal fractures......, resulting in improved articular congruence and implant positioning. METHOD: Sixty-two displaced calcaneal fractures were operated on using standard fluoroscopic views. When the surgeon had achieved a satisfactory reduction, an intraoperative 3D scan was conducted, malreductions or implant imperfections were...

  8. Tibial shaft fracture and ankle injury - Case report

    Directory of Open Access Journals (Sweden)

    Caio Zamboni

    Full Text Available ABSTRACT The authors report on a case of tibial shaft fracture associated with ankle injury. The clinical, radiological and surgical characteristics are discussed. Assessment of associated injuries is often overlooked and these injuries are hard to diagnose. When torque occurs in the lower limb, the ankle becomes susceptible to simultaneous injury. It is essential to make careful assessment based on clinical, radiographic, intraoperative and postoperative characteristics in order to attain functional recovery.

  9. Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-08-01

    Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS's navigation system overcoming the earlier version's issues, aiming to move the RAFS system into a surgical environment. The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about [Formula: see text] (phantom) and [Formula: see text] (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error [Formula: see text], [Formula: see text]. Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application.

  10. Application of Rapid Prototyping Technique and Intraoperative Navigation System for the Repair and Reconstruction of Orbital Wall Fractures

    Science.gov (United States)

    Cha, Jong Hyun; Lee, Yong Hae; Ruy, Wan Chul; Roe, Young; Moon, Myung Ho

    2016-01-01

    Background Restoring the orbital cavity in large blow out fractures is a challenge for surgeons due to the anatomical complexity. This study evaluated the clinical outcomes and orbital volume after orbital wall fracture repair using a rapid prototyping (RP) technique and intraoperative navigation system. Methods This prospective study was conducted on the medical records and radiology records of 12 patients who had undergone a unilateral blow out fracture reconstruction using a RP technique and an intraoperative navigation system from November 2014 to March 2015. The surgical results were assessed by an ophthalmic examination and a comparison of the preoperative and postoperative orbital volume ratio (OVR) values. Results All patients had a successful treatment outcome without complications. Volumetric analysis revealed a significant decrease in the mean OVR from 1.0952±0.0662 (ranging from 0.9917 to 1.2509) preoperatively to 0.9942±0.0427 (ranging from 0.9394 to 1.0680) postoperatively. Conclusion The application of a RP technique for the repair of orbital wall fractures is a useful tool that may help improve the clinical outcomes by understanding the individual anatomy, determining the operability, and restoring the orbital cavity volume through optimal implant positioning along with an intraoperative navigation system. PMID:28913272

  11. The effects of intraoperative positioning on patients undergoing early definitive care for femoral shaft fractures.

    Science.gov (United States)

    Apostle, K L; Lefaivre, K A; Guy, P; Broekhuyse, H M; Blachut, P A; O'Brien, P J; Meek, R N

    2009-10-01

    To determine if there is a difference in morbidity and mortality in orthopaedic trauma patients with femoral shaft fractures undergoing early definitive care with intramedullary (IM) nails in the supine versus the lateral position. Retrospective cohort study, single centered. One level 1 trauma center. Nine hundred eighty-eight patients representing 1027 femoral shaft fractures treated with IM nails were identified through a prospectively gathered database between 1987 and 2006. Antegrade IM nail insertion with reaming of the femoral canal in either the supine or lateral position. Mortality was the primary outcome. Admission to intensive care unit (ICU) was the secondary outcome measure and a surrogate measure of morbidity. Literature review was performed to identify factors shown to contribute to morbidity and mortality in orthopaedic trauma patients. Intraoperative position in either the supine or lateral position was added to this list. Logistic regression analysis was performed to determine the magnitude and effect of the independent variables on each of the study end points. To determine if a more significant trend toward less favorable outcomes was observed with increasing severity of injury, particularly injuries of the chest and thorax, subgroup analysis was performed for all those with a femur fracture and an Injury Severity Score > or =18 and all those with a femur fracture and an Abbreviated Injury Score chest > or =3. Intraoperative position in either the supine or lateral position was not a significant predictor of mortality or ICU admission for the original cohort or the subgroup of Injury Severity Score > or =18. However, for the subgroup of Abbreviated Injury Score chest > or =3, intraoperative positioning in the lateral position had a statistically significant protective effect against ICU admission (P = 0.044). For polytrauma patients with femoral shaft fractures, surgical stabilization using IM nails inserted with reaming of the femoral canal in

  12. Effects of Clonidine Premedication on Intraoperative Blood Loss in Patients With and Without Opium Addiction During Elective Femoral Fracture Surgeries.

    Science.gov (United States)

    Ommi, Davood; Teymourian, Houman; Zali, Alireza; Ashrafi, Farzad; Jabbary Moghaddam, Morteza; Mirkheshti, Alireza

    2015-08-01

    Opium is an addictive agent and one of the most common narcotics With great challenges of intraoperative hemodynamic instabilities. The current study aimed to assess the effects of clonidine on intraoperative blood loss in patients with and without opium addiction in femoral fracture surgeries. In a randomized clinical trial, 160 candidates for elective femoral fracture operations under general anesthesia were divided into four groups of 40 subjects: group 1 (placebo 1), subjects without addiction received placebo 90 minutes before the operation; group 2 (placebo 2), patients with opium addiction received placebo as group 1; group 3 (Clonidine 1), patients without addiction received clonidine 90 minutes before the operation and group 4 (Clonidine 2), patients with opium addiction received clonidine as premedication. Intraoperative blood loss in clonidine recipient groups, patients with and without addiction, was less than that of the placebos (both P values opium addiction. Premedication with clonidine to decrease intraoperative blood loss can be more effective in patients with opium addiction than the ones without addiction.

  13. Fracture Surgery of the extremities with the intra-operative use of 3D-RX: A randomized multicenter trial (EF3X-trial

    Directory of Open Access Journals (Sweden)

    Marmor Meir

    2011-07-01

    Full Text Available Abstract Background Posttraumatic osteoarthritis can develop after an intra-articular extremity fracture, leading to pain and loss of function. According to international guidelines, anatomical reduction and fixation are the basis for an optimal functional result. In order to achieve this during fracture surgery, an optimal view on the position of the bone fragments and fixation material is a necessity. The currently used 2D-fluoroscopy does not provide sufficient insight, in particular in cases with complex anatomy or subtle injury, and even an 18-26% suboptimal fracture reduction is reported for the ankle and foot. More intra-operative information is therefore needed. Recently the 3D-RX-system was developed, which provides conventional 2D-fluoroscopic images as well as a 3D-reconstruction of bony structures. This modality provides more information, which consequently leads to extra corrections in 18-30% of the fracture operations. However, the effect of the extra corrections on the quality of the anatomical fracture reduction and fixation as well as on patient relevant outcomes has never been investigated. The objective of this study protocol is to investigate the effectiveness of the intra-operative use of the 3D-RX-system as compared to the conventional 2D-fluoroscopy in patients with traumatic intra-articular fractures of the wrist, ankle and calcaneus. The effectiveness will be assessed in two different areas: 1 the quality of fracture reduction and fixation, based on the current golden standard, Computed Tomography. 2 The patient-relevant outcomes like functional outcome range of motion and pain. In addition, the diagnostic accuracy of the 3D-RX-scan will be determined in a clinical setting and a cost-effectiveness as well as a cost-utility analysis will be performed. Methods/design In this protocol for an international multicenter randomized clinical trial, adult patients (age > 17 years with a traumatic intra-articular fracture of the

  14. Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery.

    Science.gov (United States)

    Beerekamp, M S H; Backes, M; Schep, N W L; Ubbink, D T; Luitse, J S; Schepers, T; Goslings, J C

    2017-12-01

    Previous studies demonstrated that intra-operative fluoroscopic 3D-imaging (3D-imaging) in calcaneal fracture surgery is promising to prevent revision surgery and save costs. However, these studies limited their focus to corrections performed after 3D-imaging, thereby neglecting corrections after intra-operative fluoroscopic 2D-imaging (2D-imaging). The aim of this study was to assess the effects of additional 3D-imaging on intra-operative corrections, peri-operative imaging used, and patient-relevant outcomes compared to 2D-imaging alone. In this before-after study, data of adult patients who underwent open reduction and internal fixation (ORIF) of a calcaneal fracture between 2000 and 2014 in our level-I Trauma center were collected. 3D-imaging (BV Pulsera with 3D-RX, Philips Healthcare, Best, The Netherlands) was available as of 2007 at the surgeons' discretion. Patient and fracture characteristics, peri-operative imaging, intra-operative corrections and patient-relevant outcomes were collected from the hospital databases. Patients in whom additional 3D-imaging was applied were compared to those undergoing 2D-imaging alone. A total of 231 patients were included of whom 107 (46%) were operated with the use of 3D-imaging. No significant differences were found in baseline characteristics. The median duration of surgery was significantly longer when using 3D-imaging (2:08 vs. 1:54 h; p = 0.002). Corrections after additional 3D-imaging were performed in 53% of the patients. However, significantly fewer corrections were made after 2D-imaging when 3D-imaging was available (Risk difference (RD) -15%; 95% Confidence interval (CI) -29 to -2). Peri-operative imaging, besides intra-operative 3D-imaging, and patient-relevant outcomes were similar between groups. Intra-operative 3D-imaging provides additional information resulting in additional corrections. Moreover, 3D-imaging probably changed the surgeons' attitude to rely more on 3D-imaging, hence a 15%-decrease of

  15. Association between intraoperative blood pressure and postoperative delirium in elderly hip fracture patients.

    Directory of Open Access Journals (Sweden)

    Nae-Yuh Wang

    Full Text Available One possible area of intervention to prevent postoperative delirium (PD is intraoperative blood pressure management. However, the relationship between intraoperative blood pressure and PD is unclear. A secondary analysis of a RCT study examining the PD risk over the range of absolute intraoperative mean arterial blood pressure (MAP readings and the corresponding relative changes from preoperative baseline level was performed to determine the role of MAP on PD.Nonparametric locally weighted quadratic polynomial smoothing (LOESS regression explored the pattern of PD risk at postoperative day 2 as a function of mean surgery MAP (msMAP and percent change of msMAP from baseline in 103 elderly hip fracture patients. Segment-linear logistic regression models were then constructed to determine the odds ratios (OR of PD over the observed range of these msMAP measures, adjusting for potential confounds.Twenty-three patients (22% developed PD on day 2. LOESS regression revealed a j-shaped association between absolute levels of msMAP and PD risk. When msMAP was ≥80 mmHg, higher msMAP imparted greater PD risk (OR = 2.28 per 10 mmHg msMAP increase; 95% CI: 1.11-4.70, while higher msMAP was associated with lower PD risk (OR = 0.19 per 10 mmHg increase; CI: 0.05-0.76 if msMAP was <80 mmHg. There was no statistically significant relationship between PD risk and average percent change from baseline in these msMAP measures.In elderly hip fracture patients, both very high and very low levels of msMAP were associated with significantly increased risk of PD.

  16. Femoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction

    Directory of Open Access Journals (Sweden)

    Selahattin Ozyurek

    2015-07-01

    Full Text Available Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2 with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative distal femur fracture at a range of time intervals (1,2 intraoperative intra-articular distal femur fracture is a unique entity.However, we believe that some important additional observations seem necessary to be contributed through this study. In this article, the authors stated that, to the best of their knowledge, there is no other case report in the literature introducing a femoral condyle fracture during arthroscopic ACL reconstruction or revision reconstruction. Nevertheless, we would like to call the attention of the readers to the fact that that the literature contains one additional case report re‌porting on intraoperative distal femoral coronal plane (Hoffa fracture during primary ACL reconstruction (2. Werner BC and Miller MD presented of case report of an intraoperative distal femoral coronal plane (Hoffa fracture that occurred during independent femoral tunnel drilling and dilation in a primary ACL reconstruction. As in the their case, this type of fracture can occur with appropriately placed femoral tunnels, but the risk can increase with larger graft diameters in patients with smaller lateral femoral condyles The patient was treated with open reduction and internal fixation, without compromise of graft stability and with good recovery of function. We believe that tailoring graft size to the size of the patient is important to prevent similar adverse events.

  17. Post-Traumatic Periprosthetic Tibial and Fibular Fracture After Total Ankle Arthroplasty: A Case Report.

    Science.gov (United States)

    Brock, Amanda K; Tan, Eric W; Shafiq, Babar

    Periprosthetic fractures after total ankle arthroplasty are uncommon, with most cases occurring intraoperatively. We describe a post-traumatic periprosthetic fracture of the distal tibia and fibula after total ankle arthroplasty that was treated with minimally invasive plate osteosynthesis. It is important for orthopedic surgeons not only to recognize the risk factors for postoperative periprosthetic total ankle arthroplasty fractures, but also to be familiar with the treatment options available to maximize function and minimize complications. The design of the tibial prosthesis and surgical techniques required to prepare the ankle joint for implantation are important areas of future research to limit the risk of periprosthetic fractures. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  18. The use of intraoperative computed tomography navigation in pituitary surgery promises a better intraoperative orientation in special cases

    Directory of Open Access Journals (Sweden)

    Stefan Linsler

    2016-01-01

    Full Text Available Objective: The safety of endoscopic skull base surgery can be enhanced by accurate navigation in preoperative computed tomography (CT and magnetic resonance imaging (MRI. Here, we report our initial experience of real-time intraoperative CT-guided navigation surgery for pituitary tumors in childhood. Materials and Methods: We report the case of a 15-year-old girl with a huge growth hormone-secreting pituitary adenoma with supra- and perisellar extension. Furthermore, the skull base was infiltrated. In this case, we performed an endonasal transsphenoidal approach for debulking the adenoma and for chiasma decompression. We used an MRI neuronavigation (Medtronic Stealth Air System which was registered via intraoperative CT scan (Siemens CT Somatom. Preexisting MRI studies (navigation protocol were fused with the intraoperative CT scans to enable three-dimensional navigation based on MR and CT imaging data. Intraoperatively, we did a further CT scan for resection control. Results: The intraoperative accuracy of the neuronavigation was excellent. There was an adjustment of <1 mm. The navigation was very helpful for orientation on the destroyed skull base in the sphenoid sinus. After opening the sellar region and tumor debulking, we did a CT scan for resection control because the extent of resection was not credible evaluable in this huge infiltrating adenoma. Thereby, we were able to demonstrate a sufficient decompression of the chiasma and complete resection of the medial part of the adenoma in the intraoperative CT images. Conclusions: The use of intraoperative CT/MRI-guided neuronavigation for transsphenoidal surgery is a time-effective, safe, and technically beneficial technique for special cases.

  19. Diagnostic value of MR analysis of cartilaginous lesions compared with intraoperative arthroscopy in calcaneal fractures

    International Nuclear Information System (INIS)

    Schroeder, R.J.; Nekwasil, S.J.; Felix, R.; Hidajat, N.; Boack, D.H.; Haas, N.P.; Martus, P.

    2005-01-01

    Purpose: To determine the diagnostic value of MRI in preoperative analysis and classification of cartilaginous lesions - especially of the posterior facet - in traumatic calcaneal fractures compared with intraoperative arthroscopy. Materials and Methods: Twenty-four consecutive patients with traumatic calcaneal fractures underwent prospective MRI of the subtalar joint surface using T1- and T2-weighted spin echo sequences and fat suppressed 3D gradient echo sequences in semicoronal slice orientation (1.5 T MRI). After randomization, the images were analyzed by two blinded and independent readers experienced in MRI. The results were compared with the intraoperative arthroscopic findings as to location and depth of the defects using the Outerbridge classification. Results: We examined 12 calcaneal fractures of type 2, 8 of type 3 and 4 of type 4 according to the Sanders classification. With respect to principal detection and exact classification, 67 to 96 (69.8%) of all arthroscopic verified cartilaginous defects were diagnosed correctly by MRI. Disregarding the degree of the defects, 38 of 44 (86.4%) chondral lesions were detected (sensitivity: 86.4%, specificity: 86.5%, diagnostic accuracy: 86.5%). Considering the chondral lesions of degrees 3 and 4 together, the sensitivity was 86.0%, the specificity 86.8%, and the diagnostic accuracy 86.5%. Assessing these degrees separately, the sensitivity was only 33.3% for degree 3 and 58.1% for degree 4, whereas the specificity was definitely higher with 82.1% for degree 3 and 89.2% for degree 4. (orig.)

  20. [Anterior odontoid screw fixation using intra-operative cone-beam computed tomography and navigation].

    Science.gov (United States)

    Castro-Castro, Julián

    2014-01-01

    The purpose of this study was to asses the value of intraoperative cone-beam CT (O-arm) and stereotactic navigation for the insertion of anterior odontoid screws. this was a retrospective review of patients receiving surgical treatment for traumatic odontoid fractures during a period of 18 months. Procedures were guided with O-arm assistance in all cases. The screw position was verified with an intraoperative CT scan. Intraoperative and clinical parameters were evaluated. Odontoid fracture fusion was assessed on postoperative CT scans obtained at 3 and 6 months' follow-up Five patients were included in this series; 4 patients (80%) were male. Mean age was 63.6 years (range 35-83 years). All fractures were acute type ii odontoid fractures. The mean operative time was 116minutes (range 60-160minutes). Successful screw placement, judged by intraoperative computed tomography, was attained in all 5 patients (100%). The average preoperative and postoperative times were 8.6 (range 2-22 days) and 4.2 days (range 3-7 days) respectively. No neurological deterioration occurred after surgery. The rate of bone fusion was 80% (4/5). Although this initial study evaluated a small number of patients, anterior odontoid screw fixation utilizing the O-arm appears to be safe and accurate. This system allows immediate CT imaging in the operating room to verify screw position. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  1. Irreducible Anterior Shoulder Dislocation Associated With Displaced Fracture of the Greater Tuberosity: An Analysis of Seven Cases

    Directory of Open Access Journals (Sweden)

    Morteza Nakhaei Amroodi

    2015-11-01

    Full Text Available Background: Although anterior shoulder dislocation is the most prevalent type of body dislocation, irreducible anterior shoulder dislocation is seldom reported in the literature, which is usually due to physical obstacles. Objectives: This study presents our findings regarding the causes of irreducibility of anterior shoulder dislocation associated with displaced fracture of the greater tuberosity. Patients and Methods: CT scans, open reduction of the joint, and internal fixation of the tuberosity was performed in seven patients with irreducible anterior shoulder dislocation associated with displaced fracture of the greater tuberosity. Results: As confirmed by intraoperative findings, the CT scans showed the cause of irreducible shoulder dislocation in six cases was the interposition of the long head of biceps (LHB in the anterior of the head that was displaced from the fracture line between the greater and lesser tuberosities. In another case, the greater and lesser tuberosities were attached to each other and were separated from the head. This fractured part was trapped. Conclusions: We suggest that performing CT scans in all cases of anterior shoulder dislocations with displaced fracture of the greater tuberosity can help surgeons to diagnose the accompanying fractures and possible complications, such as irreducibility. If the fracture line passes through the bicipital groove or in the case of a shield fracture, possible irreducibility should be borne in mind.

  2. Gamma nail in the treatment of closed trochanteric fractures. Results and indications of 121 cases.

    Science.gov (United States)

    Kempf, I; Grosse, A; Taglang, G; Favreul, E

    2014-02-01

    The Gamma Nail is the latest advance in the treatment of trochanteric fractures based on intramedullary nailing principles during closed procedures. Its design is based on Küntscher's Y-nail and locking intramedullary (IM) nails. This paper reports the results from the first-ever series of 121 patients operated between 1988 and 1990. They were followed until bone union was achieved. The mean patient age was 75 years. Most patients were in poor general health and had unstable fractures. Anatomical preoperative reduction was achieved in 72% of cases. Fixation was good in 66% of cases and acceptable in 27% of cases. Intra-operative complications consisted of nine fractures without consequences. Of the treated patients, 83.4% resumed weight-bearing during the first week. There was one case of deep infection that resolved with treatment. The mortality rate was 12.3% at three months. We noted 7 alunions in varus, 3 in valgus, 2 in external rotation and 1 in internal rotation. There were no cases of non-union. In six cases, the screw had cut out of the femoral head. The drawbacks associated with surgical treatment methods for trochanteric fractures also apply to the Gamma nail. Nevertheless, one of its primary advantages is the possibility of using a closed procedure. When compared to Ender nailing, knee pain is absent and weight-bearing can be achieved in all patients, no matter the fracture type. Copyright © 2014. Published by Elsevier Masson SAS.

  3. Subtrochanteric femoral fractures treated with the Long Gamma3® nail: A historical control case study versus Long trochanteric Gamma nail®.

    Science.gov (United States)

    Georgiannos, D; Lampridis, V; Bisbinas, I

    2015-10-01

    Gamma nail was developed for the treatment of subtrochanteric hip fractures. Despite its advantages over extramedullary devices, gamma nail has been historically related to significant complications (implant breakage, femoral fractures at the tip of the nail). There is limited data to determine if the rate of these complications was minimized by using a new design of the gamma nail. Therefore we performed a case control study between the long gamma3 nail (LG3N) and the long trochanteric gamma nail (LTGN) to assess if: (1) the complication rate in the treatment of subtrochanteric fractures using the LG3N was lower than the one using the LTGN; (2) the reoperation rate was lower after using the LG3N. The complication rate after fixation of subtrochanteric fracture of the femur is lower with LG3N than with the LTGN. This study prospectively recorded the intra- and postoperative complications of 75 patients with subtrochanteric fractures treated with the LG3N and compared them with those of a historical cohort of 83 patients treated with the LTGN. The two groups were matched regarding age, gender and fracture type. Patients with open, pathological, or impending fractures were excluded. Intraoperative complications in the LG3N group were lower (4 cases, 5.3%) compared with those in the LTGN group (9 cases, 10.8%; P=0.04). The major intraoperative complication encountered with the use of LTGN was fracture of the femur in 3 cases. We encountered in total 9 postoperative complications in LG3N (12%) and 20 in group LTGN (24%). The most frequent complication in both groups was the cut out of the lag screw (3 cases in LG3N and 7 cases in LTGN group). The overall reoperation rate was higher in LTGN group (20.4% vs 10.6%; P=0.03). As a result of the improvement of its mechanical characteristics, LG3N has proved a safe and efficient implant for the treatment of subtochanteric fractures. The new design seems superior to previous generation, giving promising outcomes, reduced

  4. Laparoscopic extraction of fractured Kirschner wire from the pelvis

    Directory of Open Access Journals (Sweden)

    Vinaykumar N Thati

    2014-01-01

    Full Text Available Kirschner wire is a sharp stainless steel guide wire commonly used in fixation of fractured bone segments. There are case reports of migrated K wire from the upper limb into the spine and chest, and from the lower limb in to the abdomen and pelvis. Here, we present a case report of accidental intra-operative fracture of K wire during percutaneous femoral nailing for sub-trochanteric fracture of right femur, which migrated in to the pelvis when the orthopaedician tried to retrieve the broken segment of the K wire. This case highlights the use of laparoscopy as minimally invasive surgical option.

  5. Management of Hip Fractures in Lateral Position without a Fracture Table

    Directory of Open Access Journals (Sweden)

    Hamid Pahlavanhosseini

    2014-09-01

    Full Text Available Background:  Hip fracture Management in supine position on a fracture table with biplane fluoroscopic views has some difficulties which leads to prolongation of surgery and increasing x- rays’ dosage. The purpose of this study was to report the results and complications of hip fracture management in lateral position on a conventional operating table with just anteroposterior fluoroscopic view.  Methods:  40 hip fractures (31 trochanteric and 9 femoral neck fractures were operated in lateral position between Feb 2006 and Oct 2012. Age, gender, fracture classification, operation time, intra-operation blood loss, reduction quality, and complications were extracted from patients’ medical records. The mean follow-up time was 30.78±22.73 months (range 4-83. Results: The mean operation time was 76.50 ± 16.88 min (range 50 – 120 min.The mean intra-operative blood loss was 628.75 ± 275.00 ml (range 250-1300ml. Anatomic and acceptable reduction was observed in 95%of cases. The most important complications were malunion (one case in trochanteric group, avascular necrosis of oral head and nonunion (each one case in femoral neck group.  Conclusions:  It sounds that reduction and fixation of hip fractures in lateral position with fluoroscopy in just anteroposterior view for small rural hospitals may be executable and probably safe.

  6. Which is the ideal point of time to perform intraoperative 3D imaging in dorsal stabilisation of thoracolumbar spine fractures? A matched pair analysis.

    Science.gov (United States)

    Beck, M; Mittlmeier, T; Gierer, P; Rotter, R; Harms, C; Gradl, G

    2010-10-01

    After dorsal stabilisation of vertebral fractures by an internal fixateur the postoperative computed tomography is a standard procedure to control the positions of the pedicle screws, the success of the reposition, the clearance of the spinal canal and to plane an additive secondary ventral stabilisation. An intraoperative scan with a 3D image intensifier may clarify these questions directly after the implantation with the possibility of an immediate correction of the implants. The aim of this study was to find out the optimal point of time to perform an intraoperative 3D scan and if a postoperative computed tomography is dispensable. Intraoperative 3D scans were carried out on 33 patients with thoracolumbar spine fractures (T11-L5) after bi-segmental fixateur interne montage (Group 1). A matched pair group of 33 patients (Group 2) with a 3D scan after implantation of pedicle screws was built. A postoperative computed tomography of the instrumented spinal section was done in all patients. The following measurements were done in sagittal and axial reconstruction planes and were compared: classification of screw positions, maximal axial diameter of pedicles, cortical perforation of the screws. Additionally in Group 1 the distance between the upper and lower end plates of the injured section, the height of posterior vertebral body wall, the dislocation of the posterior wall and the minimal diameter of the spinal canal were measured. The intraoperative scoring of pedicle screws positions and the measurement of pedicle width showed in both groups a significant accordance with the computed tomography determinations. The measurements "posterior wall dislocation" and "diameter of spinal canal" were only possible in 24 3D scans and showed a significant difference compared with the CT data. The picture quality in Group 2 was scored significantly better than for Group 1 with the complete assembly of the fixateur. The ideal point of time for an intraoperative 3D imaging with

  7. Prospective study of the reproducibility of X-rays and CT scans for assessing trochanteric fracture comminution in the elderly: a series of 110 cases.

    Science.gov (United States)

    Isida, Ronald; Bariatinsky, Varenka; Kern, Gregory; Dereudre, Gregoire; Demondion, Xavier; Chantelot, Christophe

    2015-10-01

    found in 65 patients based on X-rays, 80 patients based on CT scan and 83 patients based on intraoperative findings. Comminution was mainly identified during surgery; it was medial in 34 % of cases, posterior in 22 % and posteromedial in 21.8 %. In the current study, 75.4 % of fractures were complex and unstable, with medial and/or posterior comminution present in three-quarters of these fractures. X-ray assessment underestimates posterior comminution and the complexity of the fracture line and was not very reproducible. The current results of this study suggest that comminution contributes to instability and that this finding is not taken into account in the AO classification, which is not well suited for this type of fracture and raises the question of how to best evaluate and treat these fractures. Prospective diagnostic study, Level III.

  8. Analysis of PITFL injuries in rotationally unstable ankle fractures.

    Science.gov (United States)

    Warner, Stephen J; Garner, Matthew R; Schottel, Patrick C; Hinds, Richard M; Loftus, Michael L; Lorich, Dean G

    2015-04-01

    Reduction and stabilization of the syndesmosis in unstable ankle fractures is important for ankle mortise congruity and restoration of normal tibiotalar contact forces. Of the syndesmotic ligaments, the posterior inferior tibiofibular ligament (PITFL) provides the most strength for maintaining syndesmotic stability, and previous work has demonstrated the significance of restoring PITFL function when it remains attached to a posterior malleolus fracture fragment. However, little is known regarding the nature of a PITFL injury in the absence of a posterior malleolus fracture. The goal of this study was to describe the PITFL injury pattern based on magnetic resonance imaging (MRI) and intraoperative observation. A prospective database of all operatively treated ankle fractures by a single surgeon was used to identify all supination-external rotation (SER) types III and IV ankle fracture patients with complete preoperative orthogonal ankle radiographs and MRI. All patients with a posterior malleolus fracture were excluded. Using a combination of preoperative imaging and intraoperative findings, we analyzed the nature of injuries to the PITFL. In total, 185 SER III and IV operatively treated ankle fractures with complete imaging were initially identified. Analysis of the preoperative imaging and operative reports revealed 34% (63/185) had a posterior malleolus fracture and were excluded. From the remaining 122 ankle fractures, the PITFL was delaminated from the posterior malleolus in 97% (119/122) of cases. A smaller proportion (3%; 3/122) had an intrasubstance PITFL rupture. Accurate and stable syndesmotic reduction is a significant component of restoring the ankle mortise after unstable ankle fractures. In our large cohort of rotationally unstable ankle fractures without posterior malleolus fractures, we found that most PITFL injuries occur as a delamination off the posterior malleolus. This predictable PITFL injury pattern may be used to guide new methods for

  9. Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.

    Science.gov (United States)

    Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S

    1991-02-01

    The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.

  10. Spontaneus bilateral pedicle fracture 30 years after Harrington Instrumentation for idiopathic scoliosis: a case report

    Directory of Open Access Journals (Sweden)

    Obid Peter

    2012-01-01

    Full Text Available Abstract Introduction Spontaneous fractures of the spine are a common entity. They usually occur in older people with osteoporosis. This case is presented on account of its rarity. To the best of the authors' knowledge only one case of an osteoporotic pedicle fracture after Harrington Instrumentation has been described before. Case presentation We report the case of a 46-year-old Caucasian woman who underwent surgery due to idiopathic scoliosis with a Harrington Instrumentation (T4 to L3 30 years ago. During the operation she was infected with hepatitis C while receiving erythrocyte concentrates and has suffered from liver cirrhosis since then. She presented with a sudden pain in her lower back and paraesthesia in both her legs but no other neurological symptoms. A computed tomography scan showed a bilateral pedicle fracture of L3 and an additional compression fracture of L4. In the first session we performed a dorsal stabilization with massive intraoperative bleeding and a postoperative failure of liver synthesis. In a second session an additional ventral augmentation was done. After the second operation she developed a hepatorenal syndrome. Both operations left the patient in a very critical state which led to a prolonged stay in the intensive care and rehabilitation unit. At her 12-month follow-up visit, she was free of complaints. Conclusion The un-physiological load of the spine after Harrington Instrumentation can lead to osteoporosis due to inactivity even in younger patients. Although these implants are not used anymore one should keep this possibility in mind when dealing with patients who have received Harrington rods in surgical procedures.

  11. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases.

    Science.gov (United States)

    Korkmaz, Mehmet Fatih; Erdem, Mehmet Nuri; Disli, Zeliha; Selcuk, Engin Burak; Karakaplan, Mustafa; Gogus, Abdullah

    2014-01-01

    In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF) classification and the American Society of Anesthesiologists' (ASA) physical status classification (ASA grade). Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. The mean age of the patients was 77.66 years (range: 37-98 years), and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range: 12-75 months). Postoperative radiographs showed a near-anatomical fracture reduction in 78% of patients. The Harris hip score was negatively correlated with the ASA score and patient age. No cases of implant failure were observed. Three patients died before discharge (one due to pulmonary embolism, two due to cardiac arrest), and five patients died due to unrelated medical conditions within the first 3 months of the follow-up. Our study showed that proximal femoral nail is a reliable fixation with good fracture union, and it is not associated with major complications in any type of trochanteric femoral fracture.

  12. Fracture morphology of AO/OTA 31-A trochanteric fractures: A 3D CT study with an emphasis on coronal fragments.

    Science.gov (United States)

    Cho, Jae-Woo; Kent, William T; Yoon, Yong-Cheol; Kim, Youngwoo; Kim, Hyungon; Jha, Ashutosh; Durai, Senthil Kumar; Oh, Jong-Keon

    2017-02-01

    This study was designed to assess the incidence and morphology of coronal plane fragments in AO/OTA 31-A trochanteric fractures. 156 cases of AO/OTA 31-A trochanteric fractures were retrospectively evaluated. Lateral radiographs were analyzed for the presence of coronal plane fragments followed by analysis of 3D CT reconstructions in these fractures. The incidence of coronal fragments identified on the lateral radiograph and 3D CT reconstructions were both calculated. Coronal fragment morphology was described based upon the origin and exit points of fracture lines and the number of fragments. On plain radiographs, a coronal plane fracture was identified in 59 cases, an incidence of 37.8% (59/156). In comparison, 3D CT reconstructions identified coronal plane fractures in 138 cases for an incidence of 88.4% (138/156). 3D CT reconstructions identified coronal fracture fragments in 81.9% (50/61) of AO/OTA 31-A1 cases, 94.5% (69/73) of 31-A2 cases, and 86.3% (19/22) of 31-A3 cases. Incidence of coronal fractures identified on plain radiographs of 3 AO/OTA 31-A1,A2,A3 groups was lower when compared to the incidence of coronal fractures identified on 3D CT. Of the 138 cases that had coronal plane fracture, 82 cases (59.4%) had a single coronal fragment (GT fragment 35 cases, GLT fragment 19 cases, GLPC fragment 28 cases). The remaining 56 cases (40.5%) had two coronal fragments. There is a high incidence of coronal fragments in intertrochanteric femur fractures when analyzed with 3D CT reconstructions. Our study suggests that these coronal fragments are difficult to identify on plain radiographs. Knowledge of the incidence and morphology of coronal fragments helps to avoid potential intraoperative pitfalls. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Anterior screw fixation of a dislocated type II odontoid fracture facilitated by transoral and posterior cervical manual reduction.

    Science.gov (United States)

    Piedra, Mark P; Hunt, Matthew A; Nemecek, Andrew N

    2009-10-01

    Early fixation of type II odontoid fractures has been shown to provide high rates of long-term stabilization and osteosynthesis. In this report, the authors present the case of a patient with a locked type II odontoid fracture treated by anterior screw fixation facilitated by closed transoral and posterior cervical manual reduction. While transoral intraoperative reduction of a partially displaced odontoid fracture has previously been described, the authors present the first case utilizing this technique in the treatment of a completely dislocated type II odontoid fracture.

  14. Use of a Hybrid Operating Room to Improve Reduction of Syndesmotic Injuries in Ankle Fractures: A Case Report.

    Science.gov (United States)

    Cancienne, Jourdan M; Crosen, Matelin P; Yarboro, Seth R

    2016-01-01

    Ankle fractures are one of the most common orthopedic injuries requiring operative treatment, and approximately 1 in 4 ankle fractures will have an associated distal tibiofibular syndesmosis disruption. Syndesmotic reduction is crucial to restoring ankle function and preventing the development of arthritis. The hybrid operating room provides 3-dimensional intraoperative imaging capabilities that can enable the surgeon to ensure the syndesmosis is appropriately reduced, particularly by comparing it with the contralateral ankle. By confirming the syndesmosis reduction intraoperatively, the risk of a return to the operating room for revision surgery is decreased. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Intraoperative high-field magnetic resonance imaging, multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas.

    Science.gov (United States)

    Li, Fang-Ye; Chen, Xiao-Lei; Xu, Bai-Nan

    2016-09-01

    To determine the beneficial effects of intraoperative high-field magnetic resonance imaging (MRI), multimodal neuronavigation, and intraoperative electrophysiological monitoring-guided surgery for treating supratentorial cavernomas. Twelve patients with 13 supratentorial cavernomas were prospectively enrolled and operated while using a 1.5 T intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. All cavernomas were deeply located in subcortical areas or involved critical areas. Intraoperative high-field MRIs were obtained for the intraoperative "visualization" of surrounding eloquent structures, "brain shift" corrections, and navigational plan updates. All cavernomas were successfully resected with guidance from intraoperative MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring. In 5 cases with supratentorial cavernomas, intraoperative "brain shift" severely deterred locating of the lesions; however, intraoperative MRI facilitated precise locating of these lesions. During long-term (>3 months) follow-up, some or all presenting signs and symptoms improved or resolved in 4 cases, but were unchanged in 7 patients. Intraoperative high-field MRI, multimodal neuronavigation, and intraoperative electrophysiological monitoring are helpful in surgeries for the treatment of small deeply seated subcortical cavernomas.

  16. Postoperative stroke after hemiarthroplasty for femoral neck fracture: a report of 2 cases and review of literature.

    Science.gov (United States)

    Ding, David Yi; Christoforou, Dimitrios; Turner, Garth; Tejwani, Nirmal C

    2014-06-01

    Femoral neck fractures in the elderly comprise a significant number of orthopedic surgical cases at a major trauma center. These patients are immediately incapacitated, and surgical fixation can help increase mobility, restore independence, and reduce morbidity and mortality. However, operative treatment carries its own inherent risks including infections, deep vein thromboses, and intraoperative cardiovascular collapse. Cerebrovascular stroke is a relatively uncommon occurrence after hip fractures. We present 2 cases with unusual postoperative medical complication after cemented hip hemiarthroplasty for femoral neck fracture that will serve to illustrate an infrequent but very serious complication. Case 1 was a 73-year-old man with a Garden IV femoral neck fracture who underwent a right hip unipolar cemented hemiarthroplasty under general anesthesia. After uneventful surgery, he developed neurological deficits, and a postoperative noncontrast head computed tomography showed a right medial thalamic infarct. Case 2 was an 82-year-old man with a Garden IV femoral neck fracture who underwent a right hip unipolar cemented hemiarthroplasty under general anesthesia. After uneventful surgery, the patient became hemodynamically unstable. A postoperative noncontrast head computed tomography showed a large evolving left middle cerebral artery stroke. General anesthesia in the setting of decreased cardiac function (decreased ejection fraction and output) carries the risk for ischemic injury to the brain from decreased cerebral perfusion. Risk factors including advanced age, history of coronary artery disease, atherosclerotic disease, and atrial fibrillation increase the risk for perioperative stroke. Furthermore, it is known that during the cementing of implants, microemboli can be released, which must be considered in patients with preoperative heart disease. As a result, consideration of using a noncemented implant or cementing without pressurizing in this clinical scenario

  17. Acromioclavicular Joint Dislocation with Ipsilateral Mid Third Clavicle, Mid Shaft Humerus and Coracoid Process Fracture - A Case Report.

    Science.gov (United States)

    Sharma, Naveen; Mandloi, Avinash; Agrawal, Ashish; Singh, Shailendra

    2016-01-01

    The clavicle, humerus and acromioclavicular (AC) joint separately are very commonly involved in traumatic injuries around the shoulder. Acromioclavicular joint dislocation with distal clavicle fracture is a well recognized entity in clinical practice. AC joint dislocation with mid shaft clavicle fracture is uncommon and only few cases have been reported in literature. However, to the best of our knowledge, this is the first case report to describe an acromioclavicular dislocation with ipsilateral mid shaft clavicle, mid shaft humerus and coracoid process fracture. Fractures of the humerus and clavicle along with the acromioclavicular joint dislocation were fixed at the same setting. A 65-year-old male met with a high velocity road traffic accident. Plain radiographs showed displaced mid third clavicle fracture with acromioclavicular joint dislocation with mid shaft humerus fracture. Surgical fixation was planned for humerus with interlocking nail, clavicle with locking plate and acromioclavicular joint with reconstruction of coracoclavicular ligaments. Intraoperatively, coracoid process was found to have a comminuted fracture. The operative plan had to be changed on table as coracoclavicular fixation was not possible. So acromioclavicular joint fixation was done using tension band wiring and the coracoclavicular ligament was repaired using a 2-0 ethibond. The comminuted coracoid fracture was managed conservatively. K wires were removed at 6 weeks. Early mobilization was started. In acromioclavicular joint injuries, clavicle must be evaluated for any injury. Although it is more commonly associated with distal clavicle fractures, it can be associated with middle third clavicle fractures. As plain radiographs, AP view are most of the times insufficient for viewing integrity of coracoid process, either special views like Stryker notch or CT scan may help in diagnosing such concealed injuries. When associated with fractures of the humerus and clavicle, anatomical

  18. Intraoperative panoramic image using alignment grid, is it accurate?

    Science.gov (United States)

    Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S

    2013-07-01

    Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.

  19. Intraoperative digital angiography: Peripheral vascular applications

    International Nuclear Information System (INIS)

    Bell, K.; Reifsteck, J.E.; Binet, E.F.; Fleisher, H.J.

    1986-01-01

    Intraoperative digital angiography is the procedure of choice for the peripheral vascular surgeon who wishes to evaluate his results before terminating anesthesia. Two operating suites at the John L. McClellan Memorial Veterans Hospital are equipped with permanent ceiling-mounted Philips C-arm fluoroscopes and share an ADAC 4100 digital angiographic system. In the last 18 months, 40 peripheral vascular intraoperative digital angiographic procedures have been performed, in all but two cases using direct arterial puncture. In 65% of cases, the intraoperative study showed no significant abnormality. In 12.5%, minor abnormalities not requiring reoperation were seen. In 22.5% of cases, the intraoperative digital angiogram revealed a significant abnormality requiring immediate operative revision. None of the patients who underwent reoperation experienced postoperative sequelae. Intraoperative digital angiography is useful in identifying complications of peripheral vascular operations

  20. Maxillofacial fracture experiences: a review of 152 cases.

    Science.gov (United States)

    Aydin, Osman Enver; Tan, Onder; Algan, Said; Kuduban, Selma Denktas; Barin, Ensar Zafer; Cinal, Hakan; Sarici, Murat; Avsar, Umit

    2012-12-01

    The fractures of facial structures lead to great morbidity. Cross-sectional studies are needed to evaluate the current state of maxillofacial traumas. Thus, this study aims to evaluate these experiences and to compare these results with the current literature. The medical records of the maxillofacial fracture cases hospitalized between January 2004 and November 2011 were examined. The age, sex, etiology, fracture localization and treatment method for each case were documented. The affected facial bones were grouped as mandible, maxilla, zygoma, naso-orbitoethmoid complex (NOEC) and blow-out. Nasal fractures were excluded. The cases were assigned to 3 groups with respect to age (below 16, above 65 and between 17 and 64). The chi Square test was used to assess the significance of the difference in mandibular fracture rates in the pediatric population compared to others. The total number of cases was 152. The total number of fractures was 185. Of the 152 cases, 117 were male and 35 were female. The average age was 31.4 (±18.3), ranging between 2 and 81. Thirty-one cases were 16 years old or less. Nine cases were 65 years old or more. Mandibular and zygomatic fractures were the most prevalent fractures in the adult group. Mandibular fractures were significantly more common in the pediatric age group compared to rest of the population (X(2), pOpen reduction and internal fixation was the most frequently conducted treatment modality in all age groups. Retrospective studies are important for the projection of future prospects. In summary, our results indicate that pediatric fractures are mostly in the lower face and usually affect the condylar region, which is consistent with the literature.

  1. [Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures].

    Science.gov (United States)

    Zhang, Jian; Lin, Xu; Zhong, Zeli; Wu, Chao; Tan, Lun

    2017-07-01

    To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups ( P >0.05). There was no significant difference in operation time and hospitalization stay between 2 groups ( P >0.05). But the intraoperative blood loss in group A was significantly less than that in group B ( P internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B ( P external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

  2. Evaluation of surgical treatment in mandibular condyle fractures.

    Science.gov (United States)

    Vesnaver, Aleš; Ahčan, Uroš; Rozman, Janez

    2012-12-01

    In the past, fractures of the mandibular condylar process were, as a rule, treated conservatively. At the Department of Maxillofacial and Oral Surgery of the University Medical Centre Ljubljana, Slovenia, our doctrine was changed in 2002 on the basis of preliminary results and reports in the literature, and these fractures were started to be treated surgically by open reduction and internal fixation with miniplates and screws, which led to good results and a shorter rehabilitation period. The goal of this study was to determine the safety and efficiency of surgical treatment, as well as to compare long-term results of surgical and conservative treatment, as objectively as possible. Two groups of patients, which had all sustained a unilateral, extra-articular mandibular condyle fracture, were compared. In the test group, there were 42 surgically treated patients, and in the control group, 20 conservatively treated patients. Clinical parameters and X-ray images were assessed in both groups and compared by the two tailed Student t test, and in case of attributive variables by the χ(2) test. Within the surgically treated group, postoperative and intraoperative complications were noted: temporary facial nerve palsy, development of a parotid salivary fistula, disturbance of auricle sensibility due to injury of the greater auricular nerve, miniplate fracture, as well as intraoperative bleeding, postoperative haematoma formation, infection, reoperation due to fragment malposition and other complications. Postoperative scars were also assessed. Statistically significant differences between the surgically and conservatively treated patients were found when comparing clinical parameters as well as X-ray images, the results being better in the surgically treated group. Complications of surgical treatment were also noted, the most important among them temporary paresis of facial nerve branches, which occurred in 10 patients (24%). Plate fractures occurred in five patients (12

  3. A case of lumbar pain after intraoperative radiotherapy

    International Nuclear Information System (INIS)

    Shimizu, Wakako; Ogino, Takashi; Murakami, Koji; Nawano, Shigeru; Moriyama, Noriyuki; Ryu, Munemasa; Kawano, Nariaki

    1996-01-01

    We report a case of abnormal magnetic resonance imaging (MRI) findings after intraoperative radiotherapy. A 53-year-old woman with cancer of the papilla of Vater was treated with pancreatoduodenectomy and 20 Gy of intraoperative radiotherapy by electron beam to the tumor bed. Three months later the patient complained of lumbar pain. A change of signal intensity on MRI was detected in the anterior half of the vertebral body within the irradiated field. The signal was of high intensity but was not enhanced by Gd-DTPA on T1-weighted images, was isointense on T2-weighted images and of low intensity with the fat-suppression method. The radiation dose to the lumbar spine and the surrounding soft tissue was calculated to be 16 Gy. Histologic changes in bone after irradiation may include depletion of bone marrow cells and fat degeneration. The MRI findings were compatible with these changes. The radiation dose that can be tolerated by soft tissue is lower than that tolerated by bone. Therefore, late radiation injury of the soft tissue might have been the cause of the patient's lumbar pain. (author)

  4. Fracture Penis: An Analysis of 26 Cases

    Directory of Open Access Journals (Sweden)

    G.V.Soundra Pandyan

    2006-01-01

    Full Text Available The aim of this study was to review the pattern of penile fracture occurrence, its clinical presentation, diagnosis, management, and outcome at our center. A retrospective analysis of 26 patients with penile fractures treated at our hospital from January 1997 to January 2005 was carried out. We noted an incidence of 3.5 cases per year, occurring more commonly in unmarried men. Of our study group, 28 episodes of penile fractures occurred in 26 patients. Hospital presentation after trauma varied from 2 h to 21 days. Masturbation was the main initiating causative factor and penile hematoma was the most common clinical finding. Nearly 81% noticed the characteristic click prior to the fracture. Clinical diagnosis was adequate in a majority of the cases. Midshaft fractures with right-sided laterality were more frequent in this series. The tear size ranged from 0.5—2.5 cm with a mean of 1.1 cm. All cases, but one, were treated by surgical repair using absorbable sutures. Out of three cases treated conservatively, two failed to respond and had to be treated surgically. False fracture with dorsal vein tear was present in two cases. Involvement of bilateral corpora was seen in one patient. Infection was the most common early complication, while pain with deviation was the late complication. In our experience, clinical findings are adequate enough to diagnose fracture penis in a majority of cases. Surgical exploration with repair of the tear is recommended both in early and delayed presentations. There was no noticeable relationship to the time of initial presentation or with the size and site of tear to the final outcome.

  5. Intraoperative complications in pediatric neurosurgery: review of 1807 cases.

    Science.gov (United States)

    van Lindert, Erik J; Arts, Sebastian; Blok, Laura M; Hendriks, Mark P; Tielens, Luc; van Bilsen, Martine; Delye, Hans

    2016-09-01

    OBJECTIVE Minimal literature exists on the intraoperative complication rate of pediatric neurosurgical procedures with respect to both surgical and anesthesiological complications. The aim of this study, therefore, was to establish intraoperative complication rates to provide patients and parents with information on which to base their informed consent and to establish a baseline for further targeted improvement of pediatric neurosurgical care. METHODS A clinical complication registration database comprising a consecutive cohort of all pediatric neurosurgical procedures carried out in a general neurosurgical department from January 1, 2004, until July 1, 2012, was analyzed. During the study period, 1807 procedures were performed on patients below the age of 17 years. RESULTS Sixty-four intraoperative complications occurred in 62 patients (3.5% of procedures). Intraoperative mortality was 0.17% (n = 3). Seventy-eight percent of the complications (n = 50) were related to the neurosurgical procedures, whereas 22% (n = 14) were due to anesthesiology. The highest intraoperative complication rates were for cerebrovascular surgery (7.7%) and tumor surgery (7.4%). The most frequently occurring complications were cerebrovascular complications (33%). CONCLUSIONS Intraoperative complications are not exceptional during pediatric neurosurgical procedures. Awareness of these complications is the first step in preventing them.

  6. [effectiveness of open reduction and internal fixation without opening joint capsule on tibial plateau fracture].

    Science.gov (United States)

    Chen, Qi; Xu, Xiaofeng; Huang, Yonghui; Cao, Xingbing; Meng, Chen; Cao, Xueshu; Wei, Changbao

    2014-12-01

    To introduce the surgery method to reset and fix tibial plateau fracture without opening joint capsule, and evaluate the safety and effectiveness of this method. Between July 2011 and July 2013, 51 patients with tibial plateau fracture accorded with the inclusion criteria were included. All of 51 patients, 17 cases underwent open reduction and internal fixation without opening joint capsule in trial group, and 34 cases underwent traditional surgery method in control group. There was no significant difference in gender, age, cause of injury, time from injury to admission, side of injury, and types of fracture between 2 groups (P > 0.05). The operation time, intraoperative blood loss, incision length, incision healing, and fracture healing were compared between 2 groups. The tibial-femoral angle and collapse of joint surface were measured on X-ray film. At last follow-up, joint function was evaluated with Hospital for Special Surgery (HSS) knee function scale. The intraoperative blood loss in trial group was significantly less than that in control group (P time and the rate of incision healing between 2 groups (P > 0.05). The patients were followed up 12-30 months (mean, 20.4 months) in trial group and 12-31 months (mean, 18.2 months) in control group. X-ray films indicated that all cases in 2 groups obtained fracture healing; there was no significant difference in the fracture healing time between 2 groups (t=1.382, P=0.173). On X-ray films, difference was not significant in tibial-femoral angle and collapse of joint surface between 2 groups (P > 0.05). HSS score of the knee in trial group was significantly higher than that of control group (t=3.161, P=0.003). It can reduce the intraoperative blood loss and shorten the incision length to use open reduction and internal fixation without opening joint capsule for tibial plateau fracture. Traction of joint capsule is helpful in the reduction and good recovery of joint surface collapse. In addition, the surgery without

  7. Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN Versus Dynamic Hip Screw(DHS

    Directory of Open Access Journals (Sweden)

    Cyril Jonnes

    2016-01-01

    Full Text Available Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN, in Type II intertrochanteric fractures (Boyd and Griffin classification. This study was done to compare the functional and radiological outcome of PFN with DHS in treatment of Type II intertrochanteric fractures.   Methods: From October 2012 to March 2015, a prospective comparative study was done where 30 alternative cases of type II intertrochanteric fractures of hip were operated using PFN or DHS. Intraoperative complications were noted. Functional outcome was assessed using Harris Hip Score and radiological findings were compared at 3, 6, and 12 months postoperatively. Results: The average age of the patients was 60 years. In our series we found that patients with DHS had increased intraoperative blood loss (159ml, longer duration of surgery (105min, and required longer time for mobilization while patients who underwent PFN had lower intraoperative blood loss (73ml, shorter duration of surgery (91min, and allowed early mobilization. The average limb shortening in DHS group was 9.33 mm as compared with PFN group which was only 4.72 mm. The patients treated with PFN started early ambulation as they had better Harris Hip Score in the early post-op period. At the end of 12th month, there was not much difference in the functional outcome between the two groups. Conclusion: PFN is better than DHS in type II inter-trochanteric fractures in terms of decreased blood loss, reduced duration of surgery, early weight bearing and mobilization, reduced hospital stay, decreased risk of infection and decreased complications.

  8. Rotational Mal-Alignment after Reamed Intramedullary Nailing for tibial shaft fracture.

    Science.gov (United States)

    Khan, Sher Baz; Mohib, Yasir; Rashid, Rizwan Haroon; Rashid, Haroonur

    2016-10-01

    Intra-medullary (IM) nailing is standard of care for unstable tibial shaft fractures. Malrotation is very common but it is under-recognised, inpart because of variation in normal anatomy and partly due to difficulty in accurately assessing rotation. This study was planned to evaluate the frequency of rotational mal-alignment after reamed tibia IMnailing. This cross-sectional study was conducted at Aga khan University Hospital, Karachi, and comprised patients with tibia shaft fractures managed with IMnailing from January to December 2014. All the patients were assessed intra-operatively for rotational alignment using the knee and ankle fluoroscopic images. There were 81 patients with a mean age of 38±16.9 years. There were 64(79%) male patients. Overall the incidence of malrotation was in 20(24.7%) cases. Rotational mal-alignment is one of the preventable complications after IMnailing which can be assesed intra-operatively under fluoroscope.

  9. A CASE OF GRANISETRON ASSOCIATED INTRAOPERATIVE CARDIAC ARREST.

    Science.gov (United States)

    Al Harbi, Mohammed; Al Rifai, Derar; Al Habeeb, Hassan; Wambi, Freddie; Geldhof, Georges; Dimitriou, Vassilios

    2016-02-01

    We report a case of intraoperative severe bradycardia that resulted in asystole and cardiac arrest shortly after (granisetron 1mg for postoperative nausea and vomiting prophylaxis, that occurred in a female patient who underwent an elective total thyroidectomy. After two cycles of cardiopulmonary resuscitation and defibrillation, spontaneous circulation and sinus rhythm returned successfully. Postoperatively, the patient was diagnosed with a drug-induced long QT syndrome. At the time of the event, granisetron was the only medication administered. Furthermore, there was no reason to suspect electrolyte abnormalities. We explore the association of the onset of severe sinus bradycardia with the intravenous administration of granisetron.

  10. Isolated Transverse Sacrum Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Cemil Kavalci

    2011-01-01

    Full Text Available Sacral fracture commonly results from high-energy trauma. Most insufficiency fractures of the sacrum are seen in women after the age of 70. Fractures of the sacrum are rare and generally combined with a concomitant pelvic fracture. Transverse sacral fractures are even less frequent which constitute only 3–5% of all sacral fractures. This type of fractures provide a diagnostic challenge. We report a unique case of isolated transverse fracture of sacrum in a young man sustained low-energy trauma. The patient presented to our emergency department after several hours of injury, and diagnosed by clinical features and roentgenogram findings.

  11. Osteoporosis-related fracture case definitions for population-based administrative data

    Directory of Open Access Journals (Sweden)

    Lix Lisa M

    2012-05-01

    Full Text Available Abstract Background Population-based administrative data have been used to study osteoporosis-related fracture risk factors and outcomes, but there has been limited research about the validity of these data for ascertaining fracture cases. The objectives of this study were to: (a compare fracture incidence estimates from administrative data with estimates from population-based clinically-validated data, and (b test for differences in incidence estimates from multiple administrative data case definitions. Methods Thirty-five case definitions for incident fractures of the hip, wrist, humerus, and clinical vertebrae were constructed using diagnosis codes in hospital data and diagnosis and service codes in physician billing data from Manitoba, Canada. Clinically-validated fractures were identified from the Canadian Multicentre Osteoporosis Study (CaMos. Generalized linear models were used to test for differences in incidence estimates. Results For hip fracture, sex-specific differences were observed in the magnitude of under- and over-ascertainment of administrative data case definitions when compared with CaMos data. The length of the fracture-free period to ascertain incident cases had a variable effect on over-ascertainment across fracture sites, as did the use of imaging, fixation, or repair service codes. Case definitions based on hospital data resulted in under-ascertainment of incident clinical vertebral fractures. There were no significant differences in trend estimates for wrist, humerus, and clinical vertebral case definitions. Conclusions The validity of administrative data for estimating fracture incidence depends on the site and features of the case definition.

  12. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases

    Directory of Open Access Journals (Sweden)

    Korkmaz MF

    2014-04-01

    Full Text Available Mehmet Fatih Korkmaz,1 Mehmet Nuri Erdem,2 Zeliha Disli,3 Engin Burak Selcuk,4 Mustafa Karakaplan,1 Abdullah Gogus5 1Department of Orthopedics and Traumatology, Inonu University School of Medicine, Malatya, Turkey; 2Department of Orthopedics and Traumatology, Nisantasi University School of Medicine, Istanbul, Turkey; 3Department of Anesthesiology, Malatya Government Hospital, Malatya, Turkey; 4Department of Family Medicine, Inonu University School of Medicine, Malatya, Turkey; 5Department of Orthopedics and Traumatology, Florence Nightingale Hospital, Istanbul, Turkey Purpose: In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. Materials and methods: One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF classification and the American Society of Anesthesiologists' (ASA physical status classification (ASA grade. Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. Results: The mean age of the patients was 77.66 years (range: 37–98 years, and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range

  13. Treatment of Die-Punch Fractures with 3D Printing Technology.

    Science.gov (United States)

    Chen, Chunhui; Cai, Leyi; Zhang, Chuanxu; Wang, Jianshun; Guo, Xiaoshan; Zhou, Yifei

    2017-07-19

    We evaluated the feasibility, accuracy and effectiveness of applying three-dimensional (3D) printing technology for preoperative planning for die-punch fractures. A total of 107 patients who underwent die-punch fracture surgery were enrolled in the study. They were randomly divided into two groups: 52 cases in the 3D model group and 55 cases in the routine group. A 3D digital model of each die-punch fracture was reconstructed in the 3D group. The 3D digital model was imported to a 3D printer to build the full solid model. The operation time, blood loss volume, and the number of intraoperative fluoroscopy were recorded. Follow-up was performed to evaluate the patients' surgical outcomes. Treatment of die-punch fractures using the 3D printing approach reduced the number of intraoperative fluoroscopy, blood loss volume, and operation time, but did not improve wrist function compared to those in the routine group. The patients wanted the doctor to use the 3D model to introduce the condition and operative plan because it was easier for them to understand. The orthopedic surgeons thought that the 3D model was useful for communicating with their patients, but their satisfaction with the preoperative plan was much lower than the benefit of using the 3D model to communicate with their patients. 3D printing technology produced more accurate morphometric information for orthopedists to provide personalized surgical planning and communicate better with their patients. However, it is difficult to use widely in the department of orthopedics.

  14. Cementless Stem for Femoral Neck Fractures in a Patient's 10th Decade of Life: High Rate of Periprosthetic Fractures.

    Science.gov (United States)

    Kabelitz, Method; Fritz, Yannick; Grueninger, Patrick; Meier, Christoph; Fries, Patrick; Dietrich, Michael

    2018-01-01

    Subsidence of cementless femoral stems in hemiarthroplasty (HA) and increased fracture rates are ongoing concerns of orthopedic surgeons when treating fractures in very old patients. Additionally, bone cement implantation syndrome may result in perioperative cardiac or pulmonary complications, especially in older patients, leading to morbidity and mortality. This study was performed to analyze possible subsidence and intraoperative fractures in a cohort of very old patients treated with cementless stems. We retrospectively analyzed a consecutive cohort of patients aged ≥90 years with femoral neck fractures treated by uncemented HA and an anterior minimally invasive approach. Immediate full-weight bearing was allowed postoperatively. Pelvic radiographs were examined for subsidence immediately postoperatively and 6 weeks later. We treated 109 patients (74% women; mean age, 93 years; range, 90-102 years) by HA from January 2010 to March 2016. The 30-day mortality rate was 16%, and the morbidity rate was 47%. There were 11 (12%) intraoperative fractures: 8 (Vancouver B 2 ) had to be addressed immediately during the primary operation, while 3 (1 Vancouver B 1 and 2 Vancouver A G ) were treated conservatively. One periprosthetic femoral fracture (Vancouver B 1 ) was documented during follow-up. In 17 patients, subsidence of >2.0 mm (median, 3.9 mm; range, 2.5-9.0 mm) was documented. Early subsidence was low in this very old cohort treated with an uncemented stem and not showing a periprosthetic fracture. The risk of intraoperative periprosthetic fractures was high. The use of uncemented implants in osteoporotic bone continues to be an intervention with high risk and should only be performed by experienced surgeons. Level III, Therapeutic study.

  15. The choice of surgical approach in the treatment of two-column acetabular fractures

    Directory of Open Access Journals (Sweden)

    A. A. Grin’

    2014-01-01

    Full Text Available The study aimed a comparison of treatment results in patients with two-column acetabular fractures (AO, Type C when using different operative approaches: ilioinguinal (12, Y-type (16 and a combination of posterior-lateral and ilioinguinal approaches (3. Surgical treatment was carried out not later than 3 weeks after injury. The joint congruence was reached in all the cases. The operative time, blood loss, complications, long-term results of treatment were evaluated. The study showed the effectiveness of ilioinguinal approach in case of the simple two-column fractures. When treating patients with complex fractures of the anterior column, the authors found no significant difference in operative time and intraoperative blood loss between the cases of V-type and combined approaches. In patients with two-column fractures accompanied with posterior wall lesion the time of surgery was significantly lower when using the Y-shaped approach as against the two different approaches.

  16. [Effect of 3D printing technology on pelvic fractures:a Meta-analysis].

    Science.gov (United States)

    Zhang, Yu-Dong; Wu, Ren-Yuan; Xie, Ding-Ding; Zhang, Lei; He, Yi; Zhang, Hong

    2018-05-25

    To evaluate the effect of 3D printing technology applied in the surgical treatment of pelvic fractures through the published literatures by Meta-analysis. The PubMed database, EMCC database, CBM database, CNKI database, VIP database and Wanfang database were searched from the date of database foundation to August 2017 to collect the controlled clinical trials in wich 3D printing technology was applied in preoperative planning of pelvic fracture surgery. The retrieved literatures were screened according to predefined inclusion and exclusion criteria, and quality evaluation were performed. Then, the available data were extracted and analyzed with the RevMan5.3 software. Totally 9 controlled clinical trials including 638 cases were chosen. Among them, 279 cases were assigned to the 3D printing technology group and 359 cases to the conventional group. The Meta-analysis results showed that the operative time[SMD=-2.81, 95%CI(-3.76, -1.85)], intraoperative blood loss[SMD=-3.28, 95%CI(-4.72, -1.85)] and the rate of complication [OR=0.47, 95%CI(0.25, 0.87)] in the 3D printing technology were all lower than those in the conventional group;the excellent and good rate of pelvic fracture reduction[OR=2.09, 95%CI(1.32, 3.30)] and postoperative pelvic functional restoration [OR=1.94, 95%CI(1.15, 3.28) in the 3D printing technology were all superior to those in the conventional group. 3D printing technology applied in the surgical treatment of pelvic fractures has the advantage of shorter operative time, less intraoperative blood loss and lower rate of complication, and can improve the quality of pelvic fracture reduction and the recovery of postoperative pelvic function. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  17. False negative rate of syndesmotic injury in pronation-external rotation stage IV ankle fractures

    Directory of Open Access Journals (Sweden)

    Kwang-Soon Song

    2013-01-01

    Full Text Available Background: To investigate false negative rate in the diagnosis of diastasis on initial static anteroposterior radiograph and reliability of intraoperative external rotational stress test for detection of concealed disruption of syndesmosis in pronation external rotation (PER stage IV (Lauge-Hansen ankle fractures. Materials and Methods: We prospectively studied 34 PER stage IV ankle fractures between September 2001 and September 2008. Twenty (59% patients show syndesmotic injury on initial anteroposterior radiographs. We performed an intraoperative external rotation stress test in other 14 patients with suspicious PER stage IV ankle fractures, which showed no defined syndesmotic injury on anteroposterior radiographs inspite of a medial malleolar fracture, an oblique fibular fracture above the syndesmosis and fracture of the posterior tubercle of the tibia. Results: All 14 fractures showed different degrees of tibiofibular clear space (TFCS and tibiofibular overlapping (TFO on the external rotation stress test radiograph compared to the initial plain anteroposterior radiograph. It is important to understand the fracture pattern characterstic of PER stage IV ankle fractures even though it appears normal on anteroposterior radiographs, it is to be confirmed for the concealed syndesmotic injury through a routine intraoperative external rotational stress radiograph.

  18. Cementless Stem for Femoral Neck Fractures in a Patient’s 10th Decade of Life: High Rate of Periprosthetic Fractures

    Science.gov (United States)

    Kabelitz, Method; Fritz, Yannick; Grueninger, Patrick; Meier, Christoph; Fries, Patrick

    2018-01-01

    Background: Subsidence of cementless femoral stems in hemiarthroplasty (HA) and increased fracture rates are ongoing concerns of orthopedic surgeons when treating fractures in very old patients. Additionally, bone cement implantation syndrome may result in perioperative cardiac or pulmonary complications, especially in older patients, leading to morbidity and mortality. This study was performed to analyze possible subsidence and intraoperative fractures in a cohort of very old patients treated with cementless stems. Methods: We retrospectively analyzed a consecutive cohort of patients aged ≥90 years with femoral neck fractures treated by uncemented HA and an anterior minimally invasive approach. Immediate full-weight bearing was allowed postoperatively. Pelvic radiographs were examined for subsidence immediately postoperatively and 6 weeks later. Results: We treated 109 patients (74% women; mean age, 93 years; range, 90-102 years) by HA from January 2010 to March 2016. The 30-day mortality rate was 16%, and the morbidity rate was 47%. There were 11 (12%) intraoperative fractures: 8 (Vancouver B2) had to be addressed immediately during the primary operation, while 3 (1 Vancouver B1 and 2 Vancouver AG) were treated conservatively. One periprosthetic femoral fracture (Vancouver B1) was documented during follow-up. In 17 patients, subsidence of >2.0 mm (median, 3.9 mm; range, 2.5-9.0 mm) was documented. Conclusion: Early subsidence was low in this very old cohort treated with an uncemented stem and not showing a periprosthetic fracture. The risk of intraoperative periprosthetic fractures was high. The use of uncemented implants in osteoporotic bone continues to be an intervention with high risk and should only be performed by experienced surgeons. Level of Evidence: Level III, Therapeutic study. PMID:29623237

  19. Retrospective analysis of two hundred thirty-five pediatric mandibular fracture cases.

    Science.gov (United States)

    Eskitascioglu, Teoman; Ozyazgan, Irfan; Coruh, Atilla; Gunay, Galip K; Yuksel, Esabil

    2009-11-01

    Maxillofacial fractures are encountered less commonly during childhood period due to anatomic, social, cultural, and environmental factors. Although the incidence of all maxillofacial fractures is 1% to 15% among pediatric and adolescent patients, this rate drops to less than 1% in children below 5 years age. Two hundred thirty-five cases (mandibular fracture were evaluated retrospectively. Patients records were examined in terms of age, gender, cause of fracture, fracture localization, number of fractures, fracture pattern, accompanying injuries, applied treatment methods, and complications. Mean age of cases was 9.2 years and 165 cases were male, 70 were female. Traffic accidents as the most common etiologic cause in all ages. Falls is the second most common cause which particularly affects children above age of 2 years. All cases had 333 fractures and the most common fracture localization was parasymphysis region (34%). The other most common fracture localizations were as follows: condyle (19%), corpus (13%), dentoalveolar region (12%), angulus (11%), symphysis region (9%), and ramus (2%). There was only a single fracture line in 145 cases, 40 cases had unilateral multiple and 50 cases had bilateral fracture lines. We applied symptomatic (conservative) treatment in 20 (8%) of our cases; fracture fixation with interdental wires or closed reduction methods were employed in 122 patients. Internal fixation with open reduction (OR) was performed on 51 (22%) patients. Both closed and OR techniques were carried out in 30 (13%) patients. Pediatric mandibular fractures, which are seen less frequently compared with those of adults, require a specific and different treatment. Although mostly less invasive methods are preferred, we believe that ORs should be considered when required.

  20. [Treatment of multi-segment fracture of complex femoral shaft with instrument-assisted reduction combined with intramedullary interlocking nail fixation].

    Science.gov (United States)

    Fan, Ke-Jie; Chen, Ke; Ma, Wen-Long; Tian, Ke-Wei; Ye, Ye; Chen, Hong-Gan; Tang, Yan-Feng; Cai, Hong-Min

    2018-05-25

    To investigate the effect of minimally invasive mini-incision and instrumented reduction combined with interlocking intramedullary nailing in the treatment of patients with multi-segment fracture of complex femoral shaft. From January 2013 to January 2016, 32 patients with multiple fractures segments of femoral shaft were treated with instrumentation-assisted reduction combined with interlocking intramedullary nailing, including 22 males and 10 females with an average age of 45 years old ranging 17 to 68 years old. The time from injured to operation was 5 to 10 days with an average of 7 days. After admission, routine tibial tubercle or supracondylar bone traction was performed. The patient's general condition was evaluated, the operation time and intraoperative blood loss were recorded. According to Thorsen femoral fracture morphology evaluation criteria and Hohl knee function evaluation of postoperative efficacy, postoperative fracture healing, complications and postoperative recovery of limb function were observed. All patients were followed up for 6 to 24 months with an average of 12 months. The operative time ranged from 48 to 76 minutes with an average of 67 min. The intraoperative blood loss was 150 to 400 ml with an average of 220 ml. The surgical incisions all achieved grade A healing. The fractures reached the clinical standard of healing. The fracture healing time ranged from 4.2 to 10.8 months with an average of 5.7 months. There were no nonunion, incision infection and internal fixation fracture, failure and other complications. According to Thorsen femoral fracture morphology evaluation criteria, the result was excellent in 28 cases, good in 3 cases, fair in 1 case. According to Hohl knee function evaluation criteria, the result was excellent in 30 cases, good in 2 cases. Instrument-assisted reduction combined with interlocking intramedullary nail fixation is a safe and effective method for the treatment of complex femoral shaft fractures. It has

  1. Reverse shoulder arthroplasty in acute fractures of the proximal humerus

    DEFF Research Database (Denmark)

    Brorson, Stig; Rasmussen, Jeppe; Olsen, Bo Sanderhoff

    2013-01-01

    control group of HA. The median constant score was 58 (range 44-68) which is comparable to previous reviews of HA in 4-part fractures. Complications included dislocation, infection, hematoma, instability, neurological injury, reflex sympathetic dystrophy, intraoperative fractures, periprosthetic fractures...

  2. Tight intra-operative blood pressure control versus standard care for patients undergoing hip fracture repair - Hip Fracture Intervention Study for Prevention of Hypotension (HIP-HOP) trial: study protocol for a randomised controlled trial.

    Science.gov (United States)

    Moppett, Iain Keith; White, Stuart; Griffiths, Richard; Buggy, Donal

    2017-07-25

    Hypotension during anaesthesia for hip fracture surgery is common. Recent data suggest that there is an association between the lowest intra-operative blood pressure and mortality, even when adjusted for co-morbidities. This is consistent with data derived from the wider surgical population, where magnitude and duration of hypotension are associated with mortality and peri-operative complications. However, there are no trial to data to support more aggressive blood pressure control. We are conducting a three-centre, randomised, double-blinded pilot study in three hospitals in the United Kingdom. The sample size will be 75 patients (25 from each centre). Randomisation will be done using computer-generated concealed tables. Both participants and investigators will be blinded to group allocation. Participants will be aged >70 years, cognitively intact (Abbreviated Mental Test Score 7 or greater), able to give informed consent and admitted directly through the emergency department with a fractured neck of the femur requiring operative repair. Patients randomised to tight blood pressure control or avoidance of intra-operative hypotension will receive active treatment as required to maintain both of the following: systolic arterial blood pressure >80% of baseline pre-operative value and mean arterial pressure >75 mmHg throughout. All participants will receive standard hospital care, including spinal or general anaesthesia, at the discretion of the clinical team. The primary outcome is a composite of the presence or absence of defined cardiovascular, renal and delirium morbidity within 7 days of surgery (myocardial injury, stroke, acute kidney injury, delirium). Secondary endpoints will include the defined individual morbidities, mortality, early mobility and discharge to usual residence. This is a small-scale pilot study investigating the feasibility of a trial of tight intra-operative blood pressure control in a frail elderly patient group with known high morbidity

  3. Treatment of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision: experience with 31 cases.

    Directory of Open Access Journals (Sweden)

    Jun Shi

    Full Text Available Surgery for mandibular condyle fractures must allow direct vision of the fracture, reduce surgical trauma and achieve reduction and fixation while avoiding facial nerve injury. This prospective study was conducted to introduce a new surgical approach for open reduction and internal fixation of mandibular condyle fractures using a modified transparotid approach via the parotid mini-incision, and surgical outcomes were evaluated. The modified transparotid approach via the parotid mini-incision was applied and rigid internal fixation using a small titanium plate was carried out for 36 mandibular condyle fractures in 31 cases. Postoperative follow-up of patients ranged from 3 to 26 months; in the first 3 months after surgery, outcomes for all patients were analyzed by evaluating the degree of mouth opening, occlusal relationship, facial nerve function and results of imaging studies. The occlusal relationships were excellent in all patients and none had symptoms of intraoperative ipsilateral facial nerve injury. The mean degree of mouth opening was 4.0 (maximum 4.8 cm, minimum 3.0 cm. No mandibular deviations were noted in any patient during mouth opening. CT showed complete anatomical reduction of the mandibular condyle fracture in all patients. The modified transparotid approach via the smaller, easily concealed parotid mini-incision is minimally invasive and achieves anatomical reduction and rigid internal fixation with a simplified procedure that directly exposes the fracture site. Study results showed that this procedure is safe and feasible for treating mandibular condyle fracture, and offers a short operative path, protection of the facial nerve and satisfactory aesthetic outcomes.

  4. Intraoperative radiotherapy in primary rectal cancer; Intraoperative Radiotherapie des primaeren Rektumkarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Mund, Christian

    2013-06-17

    According to the results of several studies intraoperative radiotherapy seems to influence local control for primary rectal cancer in UICC-Stage II / III positively, though recommendations in therapy cannot be given as studies of high evidence level do not exist. As IORT is rarely available and makes patient recruitment difficult, prospective randomised trials have not been carried out yet. This emphasizes the importance of non-randomised trials for an evaluation of IORT. A comparison of 21 patients with locally advanced rectal cancer who had been treated with intraoperative radiation therapy and 21 similar cases without an application of IORT could not show any significant improvements in prognosis (recurrences, metastases and disease-specific survival). Nevertheless the employment of intraoperative radiation showed a trend in improvement of local control. This hast been shown by several other studies before. Thus the application of IORT in patients with locally advanced rectal cancer is considered a useful part in multimodal treatment and should further be evaluated in specialized centres. In case-control studies 1:1-matching leads to a good comparability of groups and renders conclusions of high internal validity possible. To gain a sufficient power, this type of trials should however primarily be carried out by centres with a high number of cases.

  5. [Vertical fractures: apropos of 2 clinical cases].

    Science.gov (United States)

    Félix Mañes Ferrer, J; Micò Muñoz, P; Sánchez Cortés, J L; Paricio Martín, J J; Miñana Laliga, R

    1991-01-01

    The aim of the study is to present a clinical review of the vertical root fractures. Two clinical cases are presented to demonstrates the criteria for obtaining a correct diagnosis of vertical root fractures.

  6. Hydrogen peroxide plasma sterilization of a waterproof, high-definition video camera case for intraoperative imaging in veterinary surgery.

    Science.gov (United States)

    Adin, Christopher A; Royal, Kenneth D; Moore, Brandon; Jacob, Megan

    2018-06-13

    To evaluate the safety and usability of a wearable, waterproof high-definition camera/case for acquisition of surgical images by sterile personnel. An in vitro study to test the efficacy of biodecontamination of camera cases. Usability for intraoperative image acquisition was assessed in clinical procedures. Two waterproof GoPro Hero4 Silver camera cases were inoculated by immersion in media containing Staphylococcus pseudointermedius or Escherichia coli at ≥5.50E+07 colony forming units/mL. Cases were biodecontaminated by manual washing and hydrogen peroxide plasma sterilization. Cultures were obtained by swab and by immersion in enrichment broth before and after each contamination/decontamination cycle (n = 4). The cameras were then applied by a surgeon in clinical procedures by using either a headband or handheld mode and were assessed for usability according to 5 user characteristics. Cultures of all poststerilization swabs were negative. One of 8 cultures was positive in enrichment broth, consistent with a low level of contamination in 1 sample. Usability of the camera was considered poor in headband mode, with limited battery life, inability to control camera functions, and lack of zoom function affecting image quality. Handheld operation of the camera by the primary surgeon improved usability, allowing close-up still and video intraoperative image acquisition. Vaporized hydrogen peroxide sterilization of this camera case was considered effective for biodecontamination. Handheld operation improved usability for intraoperative image acquisition. Vaporized hydrogen peroxide sterilization and thorough manual washing of a waterproof camera may provide cost effective intraoperative image acquisition for documentation purposes. © 2018 The American College of Veterinary Surgeons.

  7. A Prospective Study to Evaluate the Management of Sub-trochanteric Femur Fractures with Long Proximal Femoral Nail.

    Science.gov (United States)

    Kumar, M; Akshat, V; Kanwariya, A; Gandhi, M

    2017-11-01

    Introduction: Sub-trochanteric fractures of the femur remains one of the most challenging fractures faced by orthopaedic surgeons. This study was done to analyse the management and complications of sub-trochanteric fractures using long proximal femoral nail (PFN). Materials and Methods: This was a prospective study of 50 patients with sub-trochanteric fractures of femur who were treated with long PFN at a tertiary care center from July 2012 to June 2016. The fractures were classified according to Seinsheimer classification. All patients were assessed functionally by Harris Hip Score. Results: Average duration of union was 17.08 weeks (range 13 to 32 weeks), union was achieved in 92% cases. Closed reduction was achieved in 68% cases and open reduction was required in 32% cases. Various intraoperative complications were seen in 12% and delayed complications in 26% of cases. Good anatomical results were achieved in 86% of cases and 14% were fair. As per Harris Hip score, excellent results were noted in 28% cases, good in 56% cases and fair in 16% cases. Conclusion: The long PFN is a reliable implant for subtrochanteric femur fractures, with high rate of bone union and minimal soft tissue damage. Intramedullary fixation has biological and biomechanical advantages, but the surgery is technically demanding.

  8. A Prospective Study to Evaluate the Management of Sub-trochanteric Femur Fractures with Long Proximal Femoral Nail

    Directory of Open Access Journals (Sweden)

    Kumar M

    2017-11-01

    Full Text Available INTRODUCTION: Sub-trochanteric fractures of the femur remains one of the most challenging fractures faced by orthopaedic surgeons. This study was done to analyse the management and complications of sub-trochanteric fractures using long proximal femoral nail (PFN. MATERIALS AND METHODS: This was a prospective study of 50 patients with sub-trochanteric fractures of femur who were treated with long PFN at a tertiary care center from July 2012 to June 2016. The fractures were classified according to Seinsheimer classification. All patients were assessed functionally by Harris Hip Score. RESULTS: Average duration of union was 17.08 weeks (range 13 to 32 weeks, union was achieved in 92% cases. Closed reduction was achieved in 68% cases and open reduction was required in 32% cases. Various intraoperative complications were seen in 12% and delayed complications in 26% of cases. Good anatomical results were achieved in 86% of cases and 14% were fair. As per Harris Hip score, excellent results were noted in 28% cases, good in 56% cases and fair in 16% cases. CONCLUSION: The long PFN is a reliable implant for sub-trochanteric femur fractures, with high rate of bone union and minimal soft tissue damage. Intramedullary fixation has biological and biomechanical advantages, but the surgery is technically demanding.

  9. Bilateral radial neck fractures – A Case Report

    Directory of Open Access Journals (Sweden)

    ABY Ng

    2007-11-01

    Full Text Available Radial head and neck fractures are the most frequently seen elbow fractures. The usual cause of this injury is a fall onto an outstretched hand with a partly flexed elbow. We report here an unusual case of bilateral non-displaced radial neck fractures in a patient who presented with complaints of pain in both elbows following a simple fall. This case highlights the need for a high index of suspicion in the diagnosis of multiple injuries, no matter how `trivial` the mechanism of injury.

  10. Intraoperative mechanical measurement of bone quality with the DensiProbe.

    Science.gov (United States)

    Hoppe, Sven; Uhlmann, Michael; Schwyn, Robert; Suhm, Norbert; Benneker, Lorin M

    2015-01-01

    Reduced bone stock can result in fractures that mostly occur in the spine, distal radius, and proximal femur. In case of operative treatment, osteoporosis is associated with an increased failure rate. To estimate implant anchorage, mechanical methods seem to be promising to measure bone strength intraoperatively. It has been shown that the mechanical peak torque correlates with the local bone mineral density and screw failure load in hip, hindfoot, humerus, and spine in vitro. One device to measure mechanical peak torque is the DensiProbe (AO Research Institute, Davos, Switzerland). The device has shown its effectiveness in mechanical peak torque measurement in mechanical testing setups for the use in hip, hindfoot, and spine. In all studies, the correlation of mechanical torque measurement and local bone mineral density and screw failure load could be shown. It allows the surgeon to judge local bone strength intraoperatively directly at the region of interest and gives valuable information if additional augmentation is needed. We summarize methods of this new technique, its advantages and limitations, and give an overview of actual and possible future applications. Copyright © 2015 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  11. Development of a semi-automated method for subspecialty case distribution and prediction of intraoperative consultations in surgical pathology

    Directory of Open Access Journals (Sweden)

    Raul S Gonzalez

    2015-01-01

    Full Text Available Background: In many surgical pathology laboratories, operating room schedules are prospectively reviewed to determine specimen distribution to different subspecialty services and to predict the number and nature of potential intraoperative consultations for which prior medical records and slides require review. At our institution, such schedules were manually converted into easily interpretable, surgical pathology-friendly reports to facilitate these activities. This conversion, however, was time-consuming and arguably a non-value-added activity. Objective: Our goal was to develop a semi-automated method of generating these reports that improved their readability while taking less time to perform than the manual method. Materials and Methods: A dynamic Microsoft Excel workbook was developed to automatically convert published operating room schedules into different tabular formats. Based on the surgical procedure descriptions in the schedule, a list of linked keywords and phrases was utilized to sort cases by subspecialty and to predict potential intraoperative consultations. After two trial-and-optimization cycles, the method was incorporated into standard practice. Results: The workbook distributed cases to appropriate subspecialties and accurately predicted intraoperative requests. Users indicated that they spent 1-2 h fewer per day on this activity than before, and team members preferred the formatting of the newer reports. Comparison of the manual and semi-automatic predictions showed that the mean daily difference in predicted versus actual intraoperative consultations underwent no statistically significant changes before and after implementation for most subspecialties. Conclusions: A well-designed, lean, and simple information technology solution to determine subspecialty case distribution and prediction of intraoperative consultations in surgical pathology is approximately as accurate as the gold standard manual method and requires less

  12. A retrospective study of fracture cases presented to university of ...

    African Journals Online (AJOL)

    In a nineteen years survey, 70 fracture cases were presented to the University of Maiduguri Veterinary Teaching Hospital (UMVTH). The percentage distribution of the fracture cases was determined according to species, etiology, affected bone, sex, age and type of fracture. The canine specie had the highest number of ...

  13. FRACTURE OF THE CENTRAL TARSAL BONE IN NONRACEHORSES: FOUR CASES.

    Science.gov (United States)

    Knuchell, Jeannie A; Spriet, Mathieu; Galuppo, Larry D; Katzman, Scott A

    2016-07-01

    Fractures of the central tarsal bone are a rarely recognized cause of acute severe hind limb lameness in nonracehorses. Diagnosis of these fractures can be challenging and little is known about their configuration or outcome. The objectives of this retrospective case series study were to describe the clinical features, imaging findings, and outcomes of fractures of the central tarsal bone in a sample of nonracehorses. Medical records from 2001 to 2014 were searched for cases of central tarsal bone fractures in nonracehorses. All available imaging findings including radiography, ultrasound, computed tomography (CT), and/or nuclear scintigraphy were reviewed. History, clinical presentation, and outcome were collected from the records. Four horses met the inclusion criteria. All had a similar configuration as a simple nondisplaced slab fracture in a dorsomedial to plantarolateral orientation. Initial radiographs failed to reveal the fracture in three of four cases. When additional plantarolateral-dorsomedial oblique radiographic views were obtained, the fracture could be identified in all cases. Fractures of the central tarsal bone seemed to occur in a consistent dorsomedial to plantarolateral orientation in this sample of nonracehorses, which is different from the configuration previously reported in racehorses. While CT can be used for detection and assessment of these fractures, authors propose that radiography can also identify these fractures with the appropriate view. Authors recommend the use of several plantarolateral to dorsomedial radiographic projections at varying degrees of obliquity for horses with a suspected central tarsal bone fracture. © 2016 American College of Veterinary Radiology.

  14. Nonunion of an isolated cuboid fracture: a case report.

    Science.gov (United States)

    Britton, Ed; Fazal, Muhammad Ali

    2013-01-01

    Nonunion of an isolated undisplaced cuboid fracture is unusual. We report a case of symptomatic nonunion of an isolated cuboid fracture after nonoperative treatment. Fracture union was achieved with surgery, and the patient returned to full activities.

  15. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    Science.gov (United States)

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  16. Callus features of regenerate fracture cases in femoral lengthening in achondroplasia

    International Nuclear Information System (INIS)

    Devmurari, Kamlesh N.; Song, Hae Ryong; Modi, Hitesh N.; Venkatesh, K.P.; Ju, Kim Seung; Song, Sang Heon

    2010-01-01

    We studied the callus features seen in cases of regenerate fracture in femoral lengthening using a monolateral fixator in achondroplasia to determine whether callus types and shapes can predict the probability of callus fracture. The radiographs of 28 cases of femoral lengthening in 14 patients, 14 cases of callus fracture, and 14 cases without callus fracture were retrospectively analyzed by four observers and classified into different shapes and types in concordance with the Ru Li classification. The average lengthening of 9.4 cm (range 7.5-11.8 cm) was achieved, which was 41% (range 30-55%) of the original length and the average timing of callus fracture was 470 days (range 440-545 days) after surgery in the callus fracture group. While the average lengthening of 9.1 cm (range 8-9.7 cm) was achieved, this was 30% (range 28-32%) of the original length in the group of patients without callus fracture. The callus was atypically shaped, there was a 48% average (range 30-72%) reduction of the callus width compared with the natural width of the femur, and a lucent pathway was present in all cases of regenerate fracture. A lucent pathway was seen in all fracture cases with concave, lateral, and atypical shapes, and there was more than 30% lengthening and 30% reduction of the callus width compared with the natural width of the femur, which are the warning signs for regenerate fractures. These signs help the surgeon to predict the outcome and guide him in planning for any additional interventions. The Ru Li classification is an effective method for the evaluation of the chance of callus fracture. (orig.)

  17. Callus features of regenerate fracture cases in femoral lengthening in achondroplasia

    Energy Technology Data Exchange (ETDEWEB)

    Devmurari, Kamlesh N.; Song, Hae Ryong; Modi, Hitesh N.; Venkatesh, K.P.; Ju, Kim Seung; Song, Sang Heon [Korea University Medical College, Institute for Rare Diseases and Department of Orthopedic Surgery, Seoul (Korea)

    2010-09-15

    We studied the callus features seen in cases of regenerate fracture in femoral lengthening using a monolateral fixator in achondroplasia to determine whether callus types and shapes can predict the probability of callus fracture. The radiographs of 28 cases of femoral lengthening in 14 patients, 14 cases of callus fracture, and 14 cases without callus fracture were retrospectively analyzed by four observers and classified into different shapes and types in concordance with the Ru Li classification. The average lengthening of 9.4 cm (range 7.5-11.8 cm) was achieved, which was 41% (range 30-55%) of the original length and the average timing of callus fracture was 470 days (range 440-545 days) after surgery in the callus fracture group. While the average lengthening of 9.1 cm (range 8-9.7 cm) was achieved, this was 30% (range 28-32%) of the original length in the group of patients without callus fracture. The callus was atypically shaped, there was a 48% average (range 30-72%) reduction of the callus width compared with the natural width of the femur, and a lucent pathway was present in all cases of regenerate fracture. A lucent pathway was seen in all fracture cases with concave, lateral, and atypical shapes, and there was more than 30% lengthening and 30% reduction of the callus width compared with the natural width of the femur, which are the warning signs for regenerate fractures. These signs help the surgeon to predict the outcome and guide him in planning for any additional interventions. The Ru Li classification is an effective method for the evaluation of the chance of callus fracture. (orig.)

  18. Transpedicular fixation for fractures treatment of the thoracolumbar and lumbar spine

    International Nuclear Information System (INIS)

    Arrieta Maria, Victor Elias; Nino Caicedo, Jose Maria

    2003-01-01

    Roy Camille first reported this technique in the 60's, but it became popular in the late 90's. This technique itself has a great biomechanical stability since it involve the anterior, medium and posterior columns of Denis, which is valuable in traumatic, deforming and degenerative pathologies. Fifty patients were reviewed in a time span from 1992 to 2002; average age 32 years, average follow up 53 months. The analyzed variables were diagnostic, mechanism of trauma, neurological deficit, additional injuries, decompressive procedures, anatomic level, number of screws used and complications. There were 30 (60%) cases of burst fractures, 17 (34%) luxofractures, two wedge fractures and one flexion-distraction fracture. the causes of the injuries found were 25 (50%) cases of vehicular motor accidents and 21 (42%) falls. the most compromised level was l1: 23 (46%) cases. eight patients required posterior decompression and five (10%) anterior decompression and five (10%) anterior decompression. 200 transpedicular screws were placed without intraoperative complications. the complications presented were: deep infection 4% material breakdown 2% bone failure 2%. there were not pseudoarthrosis

  19. Larynx trauma and hyoid bone fracture after bite injury in dog: case report

    Directory of Open Access Journals (Sweden)

    George Manchi

    2016-08-01

    Full Text Available An 8-year-old male Jack Russell crossbreed dog was admitted to our hospital with dyspnoea and shock following a dog-bite injury on the ventral neck. Radiographs revealed subcutaneous emphysema and bilateral thyrohyoid bone fractures. Intra-operatively, rupture of both sternohyoid muscles, both hyoepiglotticus muscles, both thyrohyoid muscles and a partial cranial rupture of the superficial sphincter colli muscle were detected. Part of the epiglottis was detached from the thyroid cartilage. The patient’s severed muscles and torn epiglottis were reattached using a simple interrupted suture pattern. Hyoepiglotticus muscles could not be identified. The bilateral thyrohyoid bone fractures were repaired with intraosseous wire suture. A temporary tracheostomy tube and an esophageal feeding tube were placed postoperatively. The dog was discharged after 8 days, re-examined at 2 and 6 months and laryngeal and pharyngeal function were evaluated as normal. To the authors’ knowledge, this is the first report of a dog that presented with laryngeal trauma with hyoid bone fracture and acute dyspnea who underwent surgical treatment resulting in an acceptable outcome.

  20. Larynx Trauma and Hyoid Bone Fracture after Bite Injury in Dog: Case Report

    Science.gov (United States)

    Manchi, George; Brunnberg, Mathias M.; Shahid, Muhammad; Al Aiyan, Ahmad; Brunnberg, Leo; Stein, Silke

    2016-01-01

    An 8-year-old male Jack Russell crossbreed dog was admitted to our hospital with dyspnea and shock following a dog-bite injury on the ventral neck. Radiographs revealed subcutaneous emphysema and bilateral thyrohyoid bone fractures. Intraoperatively, rupture of both sternohyoid muscles, both hyoepiglotticus muscles, both thyrohyoid muscles, and a partial cranial rupture of the superficial sphincter colli muscle were detected. Part of the epiglottis was detached from the thyroid cartilage. The patient’s severed muscles and torn epiglottis were reattached using a simple interrupted suture pattern. Hyoepiglotticus muscles could not be identified. The bilateral thyrohyoid bone fractures were repaired with intraosseous wire suture. A temporary tracheostomy tube and an esophageal feeding tube were placed postoperatively. The dog was discharged after 8 days, re-examined at 2 and 6 months and laryngeal and pharyngeal function were evaluated as normal. To the authors’ knowledge, this is the first report of a dog that presented with laryngeal trauma with hyoid bone fracture and acute dyspnea that underwent surgical treatment resulting in an acceptable outcome. PMID:27579303

  1. Evaluation of the muscle morphology of the obturator externus and piriformis as the predictors of avascular necrosis of the femoral head in acetabular fractures.

    Science.gov (United States)

    Maini, Lalit; Kumar, Santosh; Batra, Sahil; Gupta, Rajat; Arora, Sumit

    2016-08-01

    Avascular necrosis (AVN) of femoral head is a recognised complication of fracture dislocation of the hip joint but is not studied frequently in relation to acetabulum fractures. The aim was to establish the relationship between obturator externus and piriformis muscle morphology in acetabulum fractures and potenital development of AVN of the femoral head. Twenty-five fractures were included in this prospective study and were subjected to radiological assessment and computed tomography of the pelvis. Magnetic resonance imaging (MRI) of the hip was performed to assess the morphology of obturator externus and piriformis, and findings were compared intraoperatively (in 15 cases). Serial radiographs were taken at monthly intervals to assess the development of avascular necrosis. The patients with no evidence of AVN on radiographs at 6 months had additional MRI scans to look for such changes. Three patients developed AVN of femoral head and two had complete tears of piriformis and/or obturator externus muscles on the pre-operative MRI with the findings confirmed intraoperatively (p = 0.013). None of the patients without changes of AVN at 6-month follow-up had complete tears of either or both muscles. Of these patients, there was one case each of T-type fracture, isolated posterior wall fracture with hip dislocation, and posterior wall with transverse fracture of the acetabulum. Complete tears of obturator externus and/or piriformis muscles are a strong predictor of future development of AVN of the femoral head.

  2. Unusual longitudinal stress fractures of the femoral diaphysis: report of five cases

    International Nuclear Information System (INIS)

    Williams, M.; Timsit, M.A.; Karneff, A.; Pertuiset, E.

    1999-01-01

    We present five cases of a distinctive type of longitudinal stress fracture of the upper femoral shaft in which the fracture line is parallel to the outer surface of the bone, in contrast to the perpendicular orientation to the cortical surface in previously reported cases of diaphyseal stress fractures. In two cases the fracture recurred after 15 and 18 months, respectively. (orig.)

  3. [Zygomatic-orbito-malar fractures. Apropos of 85 cases].

    Science.gov (United States)

    Ait Benhamou, C; Kadiri, F; Laraqui, N; Benghalem, A; Touhami, M; Chekkoury, A; Benchakroun, Y

    1996-01-01

    Our retrospective study has concerned 85 cases of zygomatic-orbito molar fractures, hospitalised and treated from january 1983 to december 1992. 86% of patients were men. The young adult is interested in 78% of cases. The traffic accidents are predominant in 45%. The diagnosis is especially, made by the clinic and confirmed by the radiology. The abstension is justificate in 27, 1% due to the absence of deplacement and associated disorders. The orthopedic treatment concerns the len deplaced (20% of cases) and stable molar fractures. The surgery such as reduction with osteosynthesis or reconstruction of floor is realised in 55% of patients presenting deplaced fractures with norphologic and/or fonctionel disorders. The evolution is good in general. Few sequellaes has been noted in 25% cases. The authors insist on the interest of the precocity of diagnosis and treatment and on the multidisciplinar collaboration which permit an adapted treatment with few sequellaes.

  4. An Intraoperative Site-specific Bone Density Device: A Pilot Test Case.

    Science.gov (United States)

    Arosio, Paolo; Moschioni, Monica; Banfi, Luca Maria; Di Stefano, Anilo Alessio

    2015-08-01

    This paper reports a case of all-on-four rehabilitation where bone density at implant sites was assessed both through preoperative computed tomographic (CT) scans and using a micromotor working as an intraoperative bone density measurement device. Implant-supported rehabilitation is a predictable treatment option for tooth replacement whose success depends on the clinician's experience, the implant characteristics and location and patient-related factors. Among the latter, bone density is a determinant for the achievement of primary implant stability and, eventually, for implant success. The ability to measure bone density at the placement site before implant insertion could be important in the clinical setting. A patient complaining of masticatory impairment was presented with a plan calling for extraction of all her compromised teeth, followed by implant rehabilitation. A week before surgery, she underwent CT examination, and the bone density on the CT scans was measured. When the implant osteotomies were created, the bone density was again measured with a micromotor endowed with an instantaneous torque-measuring system. The implant placement protocols were adapted for each implant, according to the intraoperative measurements, and the patient was rehabilitated following an all-on-four immediate loading protocol. The bone density device provided valuable information beyond that obtained from CT scans, allowing for site-specific, intraoperative assessment of bone density immediately before implant placement and an estimation of primary stability just after implant insertion. Measuring jaw-bone density could help clinicians to select implant-placement protocols and loading strategies based on site-specific bone features.

  5. Ultrasound-Diagnosed Tibia Stress Fracture: A Case Report.

    Science.gov (United States)

    Amoako, Adae; Abid, Ayesha; Shadiack, Anthony; Monaco, Robert

    2017-01-01

    Stress fractures are a frequent cause of lower extremity pain in athletes, and especially in runners. Plain imaging has a low sensitivity. Magnetic resonance imaging (MRI) or bone scan scintigraphy is the criterion standard, but expensive. We present the case of a young female distance runner with left shin pain. Plain radiography was unremarkable. Ultrasound showed focal hyperechoic elevation of the periosteum with irregularity over the distal tibia and increased flow on Doppler. These findings were consistent with a distal tibia stress fracture and confirmed by MRI. Examination of our case will highlight the utility of considering an ultrasound for diagnosis of tibial stress fracture.

  6. Ultrasound-Diagnosed Tibia Stress Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Adae Amoako

    2017-04-01

    Full Text Available Stress fractures are a frequent cause of lower extremity pain in athletes, and especially in runners. Plain imaging has a low sensitivity. Magnetic resonance imaging (MRI or bone scan scintigraphy is the criterion standard, but expensive. We present the case of a young female distance runner with left shin pain. Plain radiography was unremarkable. Ultrasound showed focal hyperechoic elevation of the periosteum with irregularity over the distal tibia and increased flow on Doppler. These findings were consistent with a distal tibia stress fracture and confirmed by MRI. Examination of our case will highlight the utility of considering an ultrasound for diagnosis of tibial stress fracture.

  7. How evolution of the nailing system improves results and reduces orthopedic complications: more than 2000 cases of trochanteric fractures treated with the Gamma Nail System.

    Science.gov (United States)

    Pascarella, R; Fantasia, R; Maresca, A; Bettuzzi, C; Amendola, L; Violini, S; Cuoghi, F; Sangiovanni, P; Cerbasi, S; Boriani, S; Tigani, D S

    2016-04-01

    The incidence of trochanteric fractures has increased significantly during the last few decades, especially in elderly patients with osteoporosis. The dynamic/sliding hip screw and the cephalomedullary nail are the most commonly used fixation methods to treat trochanteric fractures. The improvements in the Gamma Nail System (GNS) associated with a correct surgical technique reduced the postoperative orthopedic complications. The purpose of this study was to compare the results of the different Gamma Nails. The present study is a retrospective analysis of 2144 patients treated with GNS between January 1997 and December 2011 for trochanteric fractures, classified according to AO classification method. The patients were divided into three groups according to the nailing system: 525 were treated with Standard Gamma Nail (SGN), 422 with Trochanteric Gamma Nail (TGN) and 1197 with Gamma3 Nail. The overall incidence of intra-operative complications was 1.21 %; the incidence of intra-operative complications for each group was 1.71 % for SGN group, 0.47 % for TGN group and 1.25 % for Gamma3 Nail group. The overall incidence of postoperative complications was 5.48 %, and the incidence for each group was 10.73 % for SGN group, 9.92 % for TGN group and 2.92 % for Gamma3 Nail group. The GNS is a safe device with a low rate of intra-operative complications. The evolution of this nail system reduces postoperative complications, thus improving the results at follow-up and confirming that the Gamma3 Nail is a safe and predictable device to fix trochanteric fracture.

  8. The predictive value of MRI in the syndesmotic instability of ankle fracture

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Hwan; Choi, Won Seok; Kim, Hak Jun [Korea University Guro Hospital, Department of Orthopedic Surgery, Seoul (Korea, Republic of); Yoon, Min A.; Hong, Suk Joo [Korea University Guro Hospital, Department of Radiology, Seoul (Korea, Republic of); Choi, Gi Won [Korea University Ansan Hospital, Department of Orthopedic Surgery, Ansan (Korea, Republic of)

    2018-04-15

    Although many types of ankle fracture can be combined with syndesmosis injury, preoperative imaging studies rarely reveal instability of the syndesmosis. This study assessed the use of magnetic resonance imaging (MRI) for syndesmotic instability in patients with unstable ankle fracture. A total of 74 patients who were treated for Lauge-Hansen supination external rotation/Weber B type fracture or pronation external rotation/Weber C type fracture and who underwent MRI for preoperative assessment were enrolled. The MRI findings of the syndesmotic ligament and the results of an intraoperative stress test were evaluated. Twenty-six patients had a positive result on the intraoperative stress test for syndesmotic instability. The MRI findings of the syndesmotic ligaments revealed that complete tear of the posterior inferior tibiofibular ligament (PITFL) was the most reliable predictor of syndesmotic instability (sensitivity, 74%; specificity, 78%; positive predictive value, 54%). Interobserver agreement for the intraoperative stress test and MRI assessment was excellent, except for the MRI findings of the interosseous ligament (62% agreement; kappa, 0.3). Complete tear of the PITFL on MRI has additional diagnostic value for syndesmotic instability in ankle fracture. However, because the sensitivity might not be sufficient to justify the costs associated with MRI, cost-effectiveness should be considered. (orig.)

  9. The predictive value of MRI in the syndesmotic instability of ankle fracture

    International Nuclear Information System (INIS)

    Park, Young Hwan; Choi, Won Seok; Kim, Hak Jun; Yoon, Min A.; Hong, Suk Joo; Choi, Gi Won

    2018-01-01

    Although many types of ankle fracture can be combined with syndesmosis injury, preoperative imaging studies rarely reveal instability of the syndesmosis. This study assessed the use of magnetic resonance imaging (MRI) for syndesmotic instability in patients with unstable ankle fracture. A total of 74 patients who were treated for Lauge-Hansen supination external rotation/Weber B type fracture or pronation external rotation/Weber C type fracture and who underwent MRI for preoperative assessment were enrolled. The MRI findings of the syndesmotic ligament and the results of an intraoperative stress test were evaluated. Twenty-six patients had a positive result on the intraoperative stress test for syndesmotic instability. The MRI findings of the syndesmotic ligaments revealed that complete tear of the posterior inferior tibiofibular ligament (PITFL) was the most reliable predictor of syndesmotic instability (sensitivity, 74%; specificity, 78%; positive predictive value, 54%). Interobserver agreement for the intraoperative stress test and MRI assessment was excellent, except for the MRI findings of the interosseous ligament (62% agreement; kappa, 0.3). Complete tear of the PITFL on MRI has additional diagnostic value for syndesmotic instability in ankle fracture. However, because the sensitivity might not be sufficient to justify the costs associated with MRI, cost-effectiveness should be considered. (orig.)

  10. Retrospective Analysis of 513 Cases Diagnosed with Rib Fracture Secondary to Blunt Thorax Trauma

    Directory of Open Access Journals (Sweden)

    Serdar Ozkan

    2017-05-01

    Full Text Available Aim: This study aimed to analyze blunt chest trauma cases who were diagnosed with rib fracture and to examine the regional differences likely to appear in trauma cases and treatment approaches. Material and Method: 513 cases who applied to the Emergency Service and Department of Thoracic Surgery between October 2013 and December 2014 due to blunt trauma and were diagnosed with rib fracture were retrospectively examined. The cases were evaluated in terms of etiological factors, thoracic, and other system injuries accompanying the rib fracture, prognosis, and the treatments applied. Results: Isolated rib fracture was present in 266 of the cases. Thoracic organ injuries such as pneumothorax, hemothorax, hemopneumothorax, lung contusion, or laceration and sternal fracture accompanying the rib fracture were present in 247 of the cases. While one or two rib fractures were detected in 298 cases, six or more rib fractures were present in 28 cases. 78.2% of hemothorax cases, 85.3% of pneumothorax cases, 95.4% of hemopneumothorax cases, 81.8% of bilateral pneumothorax cases, 26% of bilateral hemothorax cases, and 71.4% of bilateral hemopneumothorax cases were treated by applying tube thoracostomy. 129 cases diagnosed with thoracic organ injury in addition to rib fracture but not subjected to surgical intervention, and 266 cases diagnosed with isolated rib fracture were discharged with full recovery after appropriate medical treatment. Discussion: Most of the rib fractures occurring due to blunt trauma are treated successfully with medical treatments and conservative approaches and do not need advanced surgical treatments.

  11. Fracture of Fully-coated Femoral Stem after Primary Total Hip Arthroplasty for Nonunion of Intertrochanteric Fracture: A Case Report.

    Science.gov (United States)

    Chun, Young Soo; Juh, Hyung Suk; Cho, Yoon Je; Rhyu, Kee Hyung

    2015-09-01

    Femoral stem fracture is an uncommon reason for the failure of total hip arthroplasty, with only 16 cases of fully coated stem fractures reported to date. Here we report a case in which a fully coated primary femoral stem fracture occurred after conversion to total hip arthroplasty for the non-union of an intertrochanteric fracture of the femur. Metallurgic evaluation of the etiology and mechanism revealed that the fracture was initiated by fatigue-related failure and completed by ductile failure on the posterior side of the fracture. Considering the recent trend of treating an intertrochanteric fracture with hip arthroplasty, possible stem failure should be considered, since most patients will have at least one of the known risk factors for stem fracture.

  12. Mandibular fracture cases in Pelotas, Rio Grande do Sul, Brazil

    Directory of Open Access Journals (Sweden)

    Rafael Silva da Silva

    2009-10-01

    Full Text Available Objectives: To analyze the data in the literature, which show a high incidence of mandibular fractures. The aim of this research was to elucidate the context in which these fractures occur among patients attended at the first aid center of “Pronto Socorro Municipal de Pelotas”, Rio Grande do Sul, Brazil. Methods: From the records referring to the period of June, 2001 to August, 2007, there were 1 345 patients with facial fractures. Of this total, 116 patients with mandibular fracture were selected for this study and the items analysed were: age, gender, mandibular fracture site, etiology and period of the year. Results: It was found that 86.2% of the sample were men. The most prevalent age was 20 to 29 years old representing 36.2%, and the most affected mandibular sites were the body, with 29 cases (25%, and the condyle, with 26 cases (22.4%. The most common cause of fractures was the physical aggression representing 37.1%. The period of the year with the highest incidence of mandibular fractures was the summer, with 38 cases (32.8%. Conclusion: It was therefore observed that the patients with mandibular fracture assisted at Pronto-Socorro Municipal de Pelotas, Rio Grande do Sul, Brazil, were generally men, 20 to 29 years old with mandibular body fracture and they were victims of physical aggression.

  13. Management of pediatric mandibular fracture: a case series.

    Science.gov (United States)

    Agarwal, Ravi M; Yeluri, Ramakrishna; Singh, Chanchal; Chaudhry, Kalpna; Munshi, Autar K

    2014-09-01

    A pediatric mandibular fracture can cause a child severe pain and the parent or caregiver extreme worry. While the pattern of fractures and associated injuries in children is similar to adults, the incidence is low. Due to a number of factors, including the anatomical complexity of the developing mandible in a child, management of such fractures differs from that of adults and can greatly challenge the pediatric dentist. Various treatment modalities of managing mandibular fracture are available, such as closed/open cap splint with circummandibular wiring, arch-bar fixation, and cementation of the cap splint. This article reviews 19 cases in the management of pediatric facial fracture using varied treatment methods.

  14. Bilateral first rib fractures: A case report

    Directory of Open Access Journals (Sweden)

    Dilip Amonkar

    2014-01-01

    Full Text Available From the time first rib fractures were first described in 1869, they have been a source of anxiety to attendant trauma surgeons working in the accident and emergency department of major hospitals. First rib fractures are associated with major thoracic trauma and may involve injury to subclavian vessels, brachial plexus, and mediastinal structures. But these complications are more often seen following unilateral first rib fractures. In contrast, bilateral first rib fractures may follow insignificant trauma, suggesting a different mechanism involved. Serious vascular injuries and brachial plexus injuries are rare and angiograms for evaluation of these patients aren′t routinely warranted. The case that we report illustrates this very point.

  15. Design and evaluation of a portable intra-operative unified-planning-and-guidance framework applied to distal radius fracture surgery.

    Science.gov (United States)

    Magaraggia, Jessica; Wei, Wei; Weiten, Markus; Kleinszig, Gerhard; Vetter, Sven; Franke, Jochen; John, Adrian; Egli, Adrian; Barth, Karl; Angelopoulou, Elli; Hornegger, Joachim

    2017-01-01

    During a standard fracture reduction and fixation procedure of the distal radius, only fluoroscopic images are available for planning of the screw placement and monitoring of the drill bit trajectory. Our prototype intra-operative framework integrates planning and drill guidance for a simplified and improved planning transfer. Guidance information is extracted using a video camera mounted onto a surgical drill. Real-time feedback of the drill bit position is provided using an augmented view of the planning X-rays. We evaluate the accuracy of the placed screws on plastic bones and on healthy and fractured forearm specimens. We also investigate the difference in accuracy between guided screw placement versus freehand. Moreover, the accuracy of the real-time position feedback of the drill bit is evaluated. A total of 166 screws were placed. On 37 plastic bones, our obtained accuracy was [Formula: see text] mm, [Formula: see text] and [Formula: see text] in tip position and orientation (azimuth and elevation), respectively. On the three healthy forearm specimens, our obtained accuracy was [Formula: see text] mm, [Formula: see text] and [Formula: see text]. On the two fractured specimens, we attained: [Formula: see text] mm, [Formula: see text] and [Formula: see text]. When screw plans were applied freehand (without our guidance system), the achieved accuracy was [Formula: see text] mm, [Formula: see text], while when they were transferred under guidance, we obtained [Formula: see text] mm, [Formula: see text]. Our results show that our framework is expected to increase the accuracy in screw positioning and to improve robustness w.r.t. freehand placement.

  16. Spinal infection: Evaluation with MR imaging and intraoperative spinal US

    International Nuclear Information System (INIS)

    Donovan Post, M.J.; Montalvo, B.M.; Quencer, R.M.; Katz, B.H.; Green, B.A.; Elsmont, F.

    1987-01-01

    MR spine images and/or intraoperative US scans in 15 patients were reviewed retrospectively and correlated with clinical and pathologic data to determine the diagnostic value of these modalities in spinal infection. In osteomyelitis and retrospinal abscess MR imaging was definitive; in myelitis it was positive but nonspecific. In epidural abscess concomitant with meningitis, myelography with CT and intraoperative US were superior to MR imaging. Intraoperative US could be used to distinguish these processes and to monitor surgical decompression. The authors recommend that MR imaging be performed at the screening examination in cases of spinal infection, accompanied by intraoperative US in all surgical cases

  17. Intraoperative radiotherapy for the treatment of gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Satomura, Kisaku; Inamoto, Shun; Honda, Kazuo; Takahashi, Masaji [Kyoto Univ. (Japan). Faculty of Medicine

    1982-12-01

    Clinical results of intraoperative radiotherapy for gastric cancer were reported. One hundred and five cases of gastric cancer were treated by intraoperative radiotherapy. Whatever the stage of the patient was, 3-year survival rate was found to be better in the radiotherapy group than that of the control group (treated surgical resection only). Five year survival rate of the stages III and IV in the radiotherapy group was better than the control group. Unfavorable side effects were observed in 4 cases out of 105 cases. In one case, penetration of postoperative peptic ulcer into the irradiated aortic wall was found by autopsy. Two cases of bile duct stenosis and one case of ileus due to acutely developed peritonitis carcinomatosa were experienced. In conclusion, intraoperative radiotherapy immediately after surgical resection for the treatment of gastric cancer was found to be an effective method. The most effective application of the method appears to be to cases of stage II and III without liver metastasis and peritoneal disseminations (H/sub 0/P/sub 0/, M, A).

  18. Surgical treatment for pilon fracture of the ankle-open reduction and internal fixation.

    Science.gov (United States)

    Chen, Y W; Huang, P J; Hsu, C Y; Kuo, C H; Cheng, Y M; Lin, S Y; Chen, L H; Chiang, H C

    1998-01-01

    From 1991 to 1994, 39 ankles of 38 patients underwent surgical open reduction and internal fixation for pilon fractures. These patients included 29 males and 9 females with an average age of 38.6 y/o (range 28 y/o-58 y/o). The follow up and evaluation period averaged 31.7 months (range 22Ms-44Ms), during which time a standing x-ray for arthrosis grading and functional scale was used for clinical evaluation. Complications included 1 case of infection, 1 case of loss reduction, 2 cases of partial skin necrosis and 2 cases of delayed union. Post-traumatic arthritis occurred in 23 ankles (59%) but only 4 ankles of grade 4 arthrosis resulted in poor functional scale and the overall satisfactory rate was 82%. It was found that anatomic reduction, rigid fixation and early motion exercise are important to successful treatment of ankle fractures. Regarding pilon fracture, specifically the severity of fracture pattern and delay of reduction are important problems to overcome to ensure successful results. Therefore, adequate surgical approach for entire view of ankle joint, reduction and fixation of fibula, sufficient bone graft for articular support, intraoperative x-ray check and postoperative immobilization are essential for the achievement of better clinical results.

  19. Enhanced treatment of osteoid osteoma by intraoperative isotopic marking: a case report

    International Nuclear Information System (INIS)

    Haddam, A.; Bsiss, A.; Ech charraq, I.; BenRais, N.; Bakriga, B.; Moustain, M.R.; Hamama, J.

    2009-01-01

    Osteoid osteomas are small-sized benign painful bony tumours. Their complete surgical ablation consists in the proper treatment. The use of a portable Gamma probe allows to accurately localize the osteoid osteoma after radiolabelling and to reduce the size of incision and the bony ablation. We report the case of a patient having benefited from an isotopic intraoperative localization of an osteoid osteoma in the left tibia. Discussion chapter includes a comprehensive review of literature. (authors)

  20. A STUDY OF UNSTABLE INTERTROCHANTERIC FEMORAL FRACTURES TREATED BY TROCHANTERIC FEMORAL NAIL

    Directory of Open Access Journals (Sweden)

    Sreenivasa Neikar

    2017-11-01

    Full Text Available BACKGROUND Intertrochanteric fracture is one of the most common fracture of the hip especially in the elderly. The incidence of intertrochanteric fracture is rising because of the increase in number of elderly population along with superadded osteoporosis. MATERIALS AND METHODS Study included cases of unstable intertrochanteric fractures (AO and OTA Classification 31-A2 and 31-A3 fracture patterns that were operated with the short trochanteric femoral nail, which fitted into the inclusion criteria done in medical college hospital, Vijayanagara Institute of Medical Sciences, Bellary, from February 2015 to September 2016. RESULTS The age distribution was from 40 to 80 years. The largest group of patients were from 61 to 70 years. The average age was 60.5 years. The number of male patients in our series was 20 (66.7% and female was 10 (33.3%. Right side was affected in 11 cases (36.7% and left side in 19 cases (63.3%. Good reduction was achieved in 23 patients (76.7%. Acceptable reduction was achieved in 7 (23.3% patients due to severe comminution. In our study, 25 patients (83.33% had no complications. We encountered one intraoperative complication in the form of greater trochanter splintering, while inserting the nail. In our study, we encountered following postoperative complications. We noticed one case of delayed union, one case of Z effect and 2 cases of varus malunion. CONCLUSION We conclude that short trochanteric femoral nail provides good fixation for unstable intertrochanteric fractures if proper preoperative planning, good reduction and surgical technique are followed leading to high rate of bone union and minimal soft tissue damage especially for Asian patients with relatively small femora.

  1. Management of dental implant fractures. A case history.

    Science.gov (United States)

    Al Quran, Firas A M; Rashan, Bashar A; Al-Dwairi, Ziad N

    2009-01-01

    The widespread use of endosseous osseointegrated implants to replace missing natural teeth increases the chances of implant complications and failures, despite the high initial success rate reported in the literature. Implant fracture is one possible complication that results in ultimate failure of the dental implant. Such a complication poses a management crisis even for the most experienced clinician. This article reports on a case of implant fracture, its possible causes, and how the case was managed.

  2. [PRELIMINARY APPLICATION OF VIRTUAL PREOPERATIVE RECONSTRUCTION PLANNING IN Pilon FRACTURES].

    Science.gov (United States)

    Wang Xiaoping; Wei, Zhantu; Huang, Jian; Chen, Luyao; Hu, Shiqiang; Wu, Weiwei; Tu, Yumin; Guo, Sheng; Xu, Guotai; Deng, Zhicheng

    2016-01-01

    To investigate the application value of three-dimensional reconstruction and virtual preoperative planning for Pilon fractures. Between July 2010 and June 2014, 16 patients with closed Pilon fracture were treated, including 12 males and 4 females with an average age of 36.5 years (range, 22-53 years) and a mean disease duration of 10.2 days (range, 6-14 days). According to AO/Orthopaedic Trauma Association (AO/OTA) typing, 2 cases were rated as 43.B2 type, 3 cases as 43.B3 type, 3 cases as 43.C1 type, 2 cases as 43.C2 type, and 6 cases as 43.C3 type. The preoperative CT data from 16 patients were imported into Mimics10.01 software to establish the detailed fracture three-dimensional digital models. Virtual operation of fracture reduction and implanting internal fixation was performed on the models, and the optional surgical planning was made. Based on the virtual preoperative planning, operations were performed. Established detailed three-dimensional Pilon fracture digital models could perfectly reflect the fracture characteristics, could be observed at any direction, and aided for fracture classification accurately. Virtual fracture operations of reduction, internal fixation and other could be performed to simulate the clinical operation, which could assist the surgeon better preoperative planning in achieving visual presentation and improving the communication. The operation time was 70-130 minutes (mean, 87.8 minutes); intraoperative blood loss volume was 30-150 mL (mean, 71.9 mL). The wounds healed by first intension in all patients. The mean follow-up time was 11.6 months (range, 8-18 months). Postoperative radiological results at 3 groups showed good anatomic reduction according to the Burwell-Charnley criteria, and the fracture healing time was 3-6 months (mean, 3.7 months). There was no complication of internal fixation loosening or breakage during follow-up. The American Orthopedic Foot and Ankle Society (AOFAS) score was 71-100 (mean, 92.3); the results

  3. [Forensic Analysis of the Characteristics of Pelvic Fracture in 65 Road Traffic Accident Death Cases].

    Science.gov (United States)

    Zhang, W

    2016-12-01

    To analyze the characteristics and mechanisms of pelvic fractures in the cases of road traffic accident deaths. Total 65 cases of road traffic accident deaths with pelvic fracture were collected, and the sites, characteristics and injury mechanisms of pelvic fracture were statistically analyzed. Among the 65 cases of pelvic fracture, 38 cases of dislocation of sacroiliac joint were found, and most combined with pubis symphysis separation or fracture of pubis. In the fractures of pubis, ischium and acetabulum, linear fractures were most common, while comminuted fractures were most common in sacrum and coccyx fractures. There were 54 cases combined with pelvic soft tissue injury, and 8 cases with pelvic organ injury and 44 cases with abdominal organ injury. In the types of pelvic ring injury, 32 cases were separation, 49.32%, followed by compression, 26.15% and only one case was verticality, 1.54%. Detailed and comprehensive examination of the body and determination of the pelvic fracture type contribute to analyze the mechanisms of injury. Copyright© by the Editorial Department of Journal of Forensic Medicine

  4. BMD T-score discriminates trochanteric fractures from unfractured controls, whereas geometry discriminates cervical fracture cases from unfractured controls of similar BMD.

    Science.gov (United States)

    Pulkkinen, P; Partanen, J; Jalovaara, P; Jämsä, T

    2010-07-01

    The ability of bone mineral density (BMD) to discriminate cervical and trochanteric hip fractures was studied. Since the majority of fractures occur among people who are not diagnosed as having osteoporosis, we also examined this population to elucidate whether geometrical risk factors can yield additional information on hip fracture risk beside BMD. The study showed that the T-score criterion was able to discriminate fracture patients from controls in the cases of trochanteric fractures, whereas geometrical measures may discriminate cervical fracture cases in patients with T-score >-2.5. Low bone mineral density (BMD) is a well-established risk factor for hip fracture. However, majority of fractures occur among people not diagnosed as having osteoporosis. We studied the ability of BMD to discriminate cervical and trochanteric hip fractures. Furthermore, we examined whether geometrical measures can yield additional information on the assessment of hip fracture risk in the fracture cases in subjects with T-score >-2.5. Study group consisted of postmenopausal females with non-pathologic cervical (n = 39) or trochanteric (n = 18) hip fracture (mean age 74.2 years) and 40 age-matched controls. BMD was measured at femoral neck, and femoral neck axis length, femoral neck and shaft cortex thicknesses (FNC and FSC), and femoral neck-shaft angle (NSA) were measured from radiographs. BMD T-score threshold of -2.5 was able to discriminate trochanteric fractures from controls (p trochanteric fractures occurred in individuals with T-score fractures. Twenty of these fractures (51.3%) occurred in individuals with BMD in osteoporotic range and 19 (48.7%) in individuals with T-score >-2.5. Within these non-osteoporotic cervical fracture patients (N = 19) and non-osteoporotic controls (N = 35), 83.3% were classified correctly based on a model including NSA and FNC (p trochanteric fractures could be discriminated based on a BMD T-score fracture cases would remain under-diagnosed if

  5. Intraoperative and early postoperative complications of manual sutureless cataract extraction.

    Science.gov (United States)

    Iqbal, Yasir; Zia, Sohail; Baig Mirza, Aneeq Ullah

    2014-04-01

    To determine the intraoperative and early postoperative complications of manual sutureless cataract extraction. Case series. Redo Eye Hospital, Rawalpindi, Pakistan, from January 2009 to December 2010. Three hundred patients of cataract through purposive non-probability sampling were selected. The patients underwent manual sutureless cataract surgery (MSCS) by single experienced surgeon and intraoperative complications were documented. The surgical technique was modified to deal with any intraoperative complications accordingly. Patients were examined on the first postoperative day and on the first postoperative week for any postoperative complications. The data was entered in Statistical Package for Social Sciences (SPSS) version 13.0 and the results were calculated in frequencies. Among the 300 cases, 81.3% surgeries went uneventful whereas 18.6% had some complication. The common intraoperative complications were superior button-hole formation in 5%; posterior capsular rent in 5% and premature entry with iris prolapse in 3% cases. Postoperatively, the commonly encountered complications were striate keratopathy in 9.6% and hyphema 9%. At first week follow-up, 4% had striate keratopathy and 0.6% had hyphema. Striate keratopathy resolved with topical medication on subsequent follow-up. A total of 9 cases (3%) underwent second surgery: 2 cases for lens matter wash, 2 cases for hyphema and 5 cases needed suturing of wound for shallow anterior chamber due to wound leak. Superior button-hole formation, posterior capsular rent and premature entry were the common intraoperative complications of MSCS whereas the common early postoperative complications were striate keratopathy and hyphema.

  6. Intraoperative electrocortical stimulation of Brodman area 4: a 10-year analysis of 255 cases

    Directory of Open Access Journals (Sweden)

    Brock Mario

    2006-07-01

    Full Text Available Abstract Background Brain tumor surgery is limited by the risk of postoperative neurological deficits. Intraoperative neurophysiological examination techniques, which are based on the electrical excitability of the human brain cortex, are thus still indispensable for surgery in eloquent areas such as the primary motor cortex (Brodman Area 4. Methods This study analyzed the data obtained from a total of 255 cerebral interventions for lesions with direct contact to (121 or immediately adjacent to (134 Brodman Area 4 in order to optimize stimulation parameters and to search for direct correlation between intraoperative potential changes and specific surgical maneuvers when using monopolar cortex stimulation (MCS for electrocortical mapping and continuous intraoperative neurophysiological monitoring. Results Compound muscle action potentials (CMAPs were recorded from the thenar muscles and forearm flexors in accordance with the large representational area of the hand and forearm in Brodman Area 4. By optimizing the stimulation parameters in two steps (step 1: stimulation frequency and step 2: train sequence MCS was successful in 91% (232/255 of the cases. Statistical analysis of the parameters latency, potential width and amplitude showed spontaneous latency prolongations and abrupt amplitude reductions as a reliable warning signal for direct involvement of the motor cortex or motor pathways. Conclusion MCS must be considered a stimulation technique that enables reliable qualitative analysis of the recorded potentials, which may thus be regarded as directly predictive. Nevertheless, like other intraoperative neurophysiological examination techniques, MCS has technical, anatomical and neurophysiological limitations. A variety of surgical and non-surgical influences can be reason for false positive or false negative measurements.

  7. A Rare Case Report of an Unusual Dislocation of Fractured Mandibular Condyle

    OpenAIRE

    Mishra, Madan; Singh, Gaurav

    2015-01-01

    Several cases have been reported regarding superolateral, posterior, or superior dislocation of mandibular condyle. The anteromedial dislocation of fractured condyle is the most common among all. This article reports an unusual and unique case of dislocated fractured mandibular condyle wherein the fractured left condylar head was dislocated to the left anatomic angle of mandible. We have not found a single such case in the world English literature published till date. The presented case falls...

  8. [Gas tamponade following intraoperative pneumothorax on a single lung: A case study].

    Science.gov (United States)

    El Jaouhari, S D; Mamane Nassirou, O; Meziane, M; Bensghir, M; Haimeur, C

    2017-04-01

    Intraoperative pneumothorax is a rare complication with a high risk of cardiorespiratory arrest by gas tamponade especially on a single lung. We report the case of a female patient aged 53 years who benefited from a left pneumonectomy on pulmonary tuberculosis sequelae. The patient presented early postoperative anemia with a left hemothorax requiring an emergency thoracotomy. In perioperative, the patient had a gas tamponade following a pneumothorax of the remaining lung, and the fate has been avoided by an exsufflation. Intraoperative pneumothorax can occur due to lesions of the tracheobronchial airway, of the brachial plexus, the placement of a central venous catheter or barotrauma. The diagnosis of pneumothorax during unipulmonary ventilation is posed by the sudden onset of hypoxia associated with increased airway pressures and hypercapnia. The immediate life-saving procedure involves fine needle exsufflation before the placement of a chest tube. Prevention involves reducing the risk of barotrauma by infusing patients with low flow volumes and the proper use of positive airway pressure, knowing that despite protective ventilation, barotraumas risk still exists. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. Biomechanical comparison of two intraoperative mobilization techniques for maxillary distraction osteogenesis: Down-fracture versus non-down-fracture.

    Science.gov (United States)

    Yang, Lili; Suzuki, Eduardo Yugo; Suzuki, Boonsiva

    2014-01-01

    The purpose of this study was to compare the distraction forces and the biomechanical effects between two different intraoperative surgical procedures (down-fracture [DF] and non-DF [NDF]) for maxillary distraction osteogenesis. Eight patients were assigned into two groups according to the surgical procedure: DF, n = 6 versus NDF, n = 2. Lateral cephalograms taken preoperatively (T1), immediately after removal of the distraction device (T2), and after at least a 6 months follow-up period (T3) were analyzed. Assessment of distraction forces was performed during the distraction period. The Mann-Whitney U-test was used to compare the difference in the amount of advancement, the maximum distraction force and the amount of relapse. Although a significantly greater amount of maxillary movement was observed in the DF group (median 9.5 mm; minimum-maximum 7.9-14.1 mm) than in the NDF group (median 5.9 mm; minimum-maximum 4.4-7.6 mm), significantly lower maximum distraction forces were observed in the DF (median 16.4 N; minimum-maximum 15.1-24.6 N) than in the NDF (median 32.9 N; minimum-maximum 27.6-38.2 N) group. A significantly greater amount of dental anchorage loss was observed in the NDF group. Moreover, the amount of relapse observed in the NDF group was approximately 3.5 times greater than in the DF group. In this study, it seemed that, the use of the NDF procedure resulted in lower levels of maxillary mobility at the time of the maxillary distraction, consequently requiring greater amounts of force to advance the maxillary bone. Moreover, it also resulted in a reduced amount of maxillary movement, a greater amount of dental anchorage loss and poor treatment stability.

  10. Acetabular fractures following rugby tackles: a case series

    LENUS (Irish Health Repository)

    Good, Daniel W

    2011-10-05

    Abstract Introduction Rugby is the third most popular team contact sport in the world and is increasing in popularity. In 1995, rugby in Europe turned professional, and with this has come an increased rate of injury. Case presentation In a six-month period from July to December, two open reduction and internal fixations of acetabular fractures were performed in young Caucasian men (16 and 24 years old) who sustained their injuries after rugby tackles. Both of these cases are described as well as the biomechanical factors contributing to the fracture and the recovery. Acetabular fractures of the hip during sport are rare occurrences. Conclusion Our recent experience of two cases over a six-month period creates concern that these high-energy injuries may become more frequent as rugby continues to adopt advanced training regimens. Protective equipment is unlikely to reduce the forces imparted across the hip joint; however, limiting \\'the tackle\\' to only two players may well reduce the likelihood of this life-altering injury.

  11. Case report 491: Stress fracture of the right sacrum

    Energy Technology Data Exchange (ETDEWEB)

    Hoang, T.A.; Nguyen, T.H.; Daffner, R.H.; Lupetin, A.R.; Deeb, Z.L.

    1988-07-01

    A case of stress fracture of the right sacrum in a postpartum woman has been presented. Key features in making the diagnosis include a history of pain in the sacrum, considerable weight gain during the pregnancy and pronounced increased physical activity in the immediate postpartum period. CT, particularly, and MRI were critical in making the diagnosis. A low signal area on the T-1 neglected image was considered characteristic for the sacral fracture. In the CT studies a vertical lucency thru a zone of sclerosis is classical for a fracture, whether an insufficiency fracture or a fatigue fracture.

  12. Treatment of trochanteric fractures with the gamma3 nail - methodology and early results of a prospective consecutive monitored clinical case series.

    Science.gov (United States)

    A C, Unger; E, Wilde; B, Kienast; C, Jürgens; A P, Schulz

    2014-01-01

    There is only sparse data on clinical results and complications of the third-generation Gamma nailing system (Gamma3, Stryker). Therefore, we started a large multi-centre case series in 2008. The aim of this paper is to present the study design and early results of a single arm of a prospective, consecutive, monitored, post-market follow-up evaluation of Gamma3 nails. From September 2009 to January 2012, 154 consecutive patients with an average age of 80 ± 1.43 years (50-99 years) and a trochanteric femoral fracture were included in the local arm of the trial. All patients that fulfilled the inclusion criteria were treated with a Gamma3 nail. Preoperative variables included age, gender, fracture classification, walking ability (Merle d'Aubigné score), daily activity level (retrospective Zuckerman score), ASA rating of operative risk, waiting time for operation, use of walker or crutches and body mass index (BMI). Skin-to-skin time, fluoroscopy time, blood loss, intraoperative complications and device information were recorded for each patient. Follow-up postoperative assessment was undertaken at 4, 12 and 24 months. Hip range of motion, pain around the hip and the tight, walking ability (Merle d'Aubigné score, Sahlgrenska mobility score) and management of daily life (Zuckerman score) were used to evaluate the outcome. The descriptive data of age, gender, BMI, ASA classification, fracture type and skin-to-skin time is similar to other studies. Median fluoroscopy time was 62 seconds (range: 4-225 seconds) and significantly shorter in closed reductions. No intraoperative implant-related complication was recorded. A cut-out of the leg-screw during assessment period occurred in 2.6% patients (n = 4). At the 12-month assessment two (1.8%) non-unions were identified and two patients (1.8%) had broken the femoral shaft below the 180 mm nail after a fall. Analysis of the scores showed significantly declined mobility and activity in daily life four months after operation

  13. A Complex Facial Trauma Case with Multiple Mandibular Fractures and Dentoalveolar Injuries

    Directory of Open Access Journals (Sweden)

    Yeliz Guven

    2015-01-01

    Full Text Available The principles of management of mandibular fractures differ in children when compared to adults and depend on the specific age-related status of the growing mandible and the developing dentition. This paper presents a case report with a complex facial trauma affecting the mandibular body and condyle region and dentoalveolar complex. Clinical examination revealed soft tissue injuries, limited mouth opening, lateral deviation of the mandible, an avulsed incisor, a subluxated incisor, and a fractured crown. CBCT examination revealed a nondisplaced fracture and an oblique greenstick fracture of the mandibular body and unilateral fracture of the condyle. Closed reduction technique was chosen to manage fractures of the mandible. Favorable healing outcomes on multiple fractures of the mandible throughout the 6-year follow-up period proved the success of the conservative treatment. This case report is important since it presents a variety of pathological sequelae to trauma within one case.

  14. Ankle fracture spur sign is pathognomonic for a variant ankle fracture.

    Science.gov (United States)

    Hinds, Richard M; Garner, Matthew R; Lazaro, Lionel E; Warner, Stephen J; Loftus, Michael L; Birnbaum, Jacqueline F; Burket, Jayme C; Lorich, Dean G

    2015-02-01

    The hyperplantarflexion variant ankle fracture is composed of a posterior tibial lip fracture with posterolateral and posteromedial fracture fragments separated by a vertical fracture line. This infrequently reported injury pattern often includes an associated "spur sign" or double cortical density at the inferomedial tibial metaphysis. The objective of this study was to quantitatively establish the association of the ankle fracture spur sign with the hyperplantarflexion variant ankle fracture. Our clinical database of operative ankle fractures was retrospectively reviewed for the incidence of hyperplantarflexion variant and nonvariant ankle fractures as determined by assessment of injury radiographs, preoperative advanced imaging, and intraoperative observation. Injury radiographs were then evaluated for the presence of the spur sign, and association between the spur sign and variant fractures was analyzed. The incidence of the hyperplantarflexion variant fracture among all ankle fractures was 6.7% (43/640). The spur sign was present in 79% (34/43) of variant fractures and absent in all nonvariant fractures, conferring a specificity of 100% in identifying variant fractures. Positive predictive value and negative predictive value were 100% and 99%, respectively. The ankle fracture spur sign was pathognomonic for the hyperplantarflexion variant ankle fracture. It is important to identify variant fractures preoperatively as patient positioning, operative approach, and fixation construct of variant fractures often differ from those employed for osteosynthesis of nonvariant fractures. Identification of the spur sign should prompt acquisition of advanced imaging to formulate an appropriate operative plan to address the variant fracture pattern. Level III, retrospective comparative study. © The Author(s) 2014.

  15. Ipsilateral Traumatic Posterior Hip Dislocation, Posterior Wall and Transverse Acetabular Fracture with Trochanteric Fracture in an adult: Report of First Case

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2013-10-01

    Full Text Available Introduction: Posterior dislocation of the hip joint with associated acetabular and intertrochanteric fracture is a complex injury. Early recognition, prompt and stable reduction is needed of successful outcome. Case Report: 45 year old male patient presented with posterior dislocation of the hip with transverse fracture with posterior wall fracture of acetabulam and intertrochanteric fracture on the ipsilateral side. The complex fracture geometry was confirmed by CT scan. The patient was successfully managed by open reduction and internal fixation of intertrochanteric fracture was achieved with dynamic hip screw (DHS plate fixation followed by fixation of acetabular fracture with reconstruction plate. Conclusion: Hip dislocation combined with acetabular fracture is an uncommon injury; this article presents a unique case of posterior wall and transverse fractures of ipsilateral acetabulum with intertrochanteric fracture in a patient who sustained traumatic posterior hip dislocation. Early surgical intervention is important for satisfactory outcomes of such complex fracture-dislocation injuries. Keywords: Hip dislocation; acetabular fractures; intertrochanteric fracture; operative treatment.

  16. Intraoperative floppy iris and prevalence of intraoperative complications: results from ophthalmic surgery outcomes database.

    Science.gov (United States)

    Vollman, David E; Gonzalez-Gonzalez, Luis A; Chomsky, Amy; Daly, Mary K; Baze, Elizabeth; Lawrence, Mary

    2014-06-01

    To estimate the prevalence of untoward events during cataract surgery with the use of pupillary expansion devices and intraoperative floppy iris (IFIS). Retrospective analysis of 4923 cataract surgery cases from the Veterans Affairs Ophthalmic Surgical Outcomes Data Project. Outcomes from 5 Veterans Affairs medical centers were analyzed, including use of alpha-blockers (both selective and nonselective), IFIS, intraoperative iris trauma, intraoperative iris prolapse, posterior capsular tear, anterior capsule tear, intraoperative vitreous prolapse, and use of pupillary expansion devices. P values were calculated using the χ(2) test. A total of 1254 patients (25.5%) took alpha-blockers preoperatively (selective, 587; nonselective, 627; both, 40). Of these 1254 patients, 428 patients (34.1%) had documented IFIS. However, 75.2% of patients with IFIS (428/569) had taken alpha-blockers preoperatively (P < .00001). A total of 430 patients (8.7%) had a pupillary expansion device used during their cataract surgery, of which 186 patients (43.4%) had IFIS (P < .0001). Eighty-six patients with IFIS had at least 1 intraoperative complication and 39 patients with IFIS had more than 1 intraoperative complication (P < .001). The use of either selective or nonselective alpha-antagonists preoperatively demonstrated a significant risk of IFIS. Nonselective alpha-antagonists caused IFIS at a higher prevalence than previously reported. This study did demonstrate statistically significant increased odds of surgical complications in patients with IFIS vs those without IFIS in all groups (those taking selective and nonselective alpha-antagonists and also those not taking medications). Published by Elsevier Inc.

  17. Cronkhite-Canada syndrome associated with rib fractures: a case report

    Directory of Open Access Journals (Sweden)

    Wan Haijun

    2010-10-01

    Full Text Available Abstract Background Cronkhite-Canada syndrome (CCS is a rare multiple gastrointestinal polyposis. Up till now, many complications of CCS have been reported in the literature, but rib fracture is not included. Case Presentation We report a case of a 58-year-old man who was admitted to our hospital with a 6-month history of frequent diarrhea, intermittent hematochezia and a weight loss of 13 kg. On admission, physical examination revealed alopecia of the scalp, hyperpigmentation of the hands and soles, and dystrophy of the fingernails. Laboratory data revealed hypocalcaemia and hypoproteinemia. Esophagogastroduodenoscopy, video capsule endoscopy and colonoscopy revealed various sizes of generalized gastrointestinal polyps. Histological examination of the biopsy specimens obtained from the stomach and the colon showed adenomatous polyp and inflammatory polyp respectively. Thus, a diagnosis of CCS was made. After treatment with corticosteroids for 24 days and nutritional support for two months, his clinical condition improved. Two months later, he was admitted to our hospital for the second time with frequent diarrhea and weight loss. The chest radiography revealed fractures of the left sixth and seventh ribs. Examinations, including emission computed tomography, bone densitometry test, and other serum parameters, were performed, but could not identify the definite etiology of the rib fractures. One month later, the patient suffered from aggravating multiple rib fractures due to the ineffective treatment, persistent hypocalcaemia and malnutrition. Conclusions This is the first case of a CCS patient with multiple rib fractures. Although the association between CCS and multiple rib fractures in this case remains uncertain, we presume that persistent hypocalcaemia and malnutrition contribute to this situation, or at least aggravate this rare complication. Besides, since prolonged corticosteroid therapy will result in an increased risk of osteoporotic

  18. Intraoperative /sup 99m/Tc bone imaging in the treatment of benign osteoblastic tumors

    International Nuclear Information System (INIS)

    Sty, J.; Simons, G.

    1982-01-01

    Benign bone tumors can be successfully treated by local resection with the use of intraoperative bone imaging. Intraoperative bone imaging provided accurate localization of an osteoid osteoma in a patella of a 16-year-old girl when standard radiographs failed to demonstrate the lesion. In a case of osteoblastoma of the sacrum in a 12-year old girl, intraoperative scanning was used repeatedly to guide completeness of resection. In these cases in which routine intraoperative radiographs would have failed, intraoperative scanning proved to be essential for success

  19. Intraoperative verification of hysterosalpingography and laparoscopy in cases of oviductal infertility

    International Nuclear Information System (INIS)

    Cislo, M.; Murawski, M.; Popiela, A.

    1993-01-01

    There has been made an analysis of 45 cases of women's oviductal infertility qualified to surgical treatment. In search of these reasons of infertility these patients underwent hysterosalpingographic examination and 24 of them additionally, diagnostic laparoscopy with chromoturbation. Positive intraoperative verification of HSG and laparoscopy, as a confirmation of tubal obstruction, they obtained at 40 women (88.9%) that made possible to carry out microsurgical operations in them. Such a big percentage of correct diagnoses make sure, that both HSG and laparoscopy are indispensable for proper qualification of a patient to microsurgical treatment of oviductal infertility. (author)

  20. Intraoperative and Early Postoperative Complications of Manual Sutureless Cataract Extraction

    International Nuclear Information System (INIS)

    Iqbal, Y.; Zia, S.; Mirza, A. B.

    2014-01-01

    Objective: To determine the intraoperative and early postoperative complications of manual sutureless cataract extraction. Study Design: Case series. Place and Duration of Study: Redo Eye Hospital, Rawalpindi, Pakistan, from January 2009 to December 2010. Methodology: Three hundred patients of cataract through purposive non-probability sampling were selected. The patients underwent manual sutureless cataract surgery (MSCS) by single experienced surgeon and intraoperative complications were documented. The surgical technique was modified to deal with any intraoperative complications accordingly. Patients were examined on the first postoperative day and on the first postoperative week for any postoperative complications. The data was entered in Statistical Package for Social Sciences (SPSS) version 13.0 and the results were calculated in frequencies. Results: Among the 300 cases, 81.3% surgeries went uneventful whereas 18.6% had some complication. The common intraoperative complications were superior button-hole formation in 5%; posterior capsular rent in 5% and premature entry with iris prolapse in 3% cases. Postoperatively, the commonly encountered complications were striate keratopathy in 9.6% and hyphema 9%. At first week follow-up, 4% had striate keratopathy and 0.6% had hyphema. Striate keratopathy resolved with topical medication on subsequent follow-up. A total of 9 cases (3%) underwent second surgery: 2 cases for lens matter wash, 2 cases for hyphema and 5 cases needed suturing of wound for shallow anterior chamber due to wound leak. Conclusion: Superior button-hole formation, posterior capsular rent and premature entry were the common intraoperative complications of MSCS whereas the common early postoperative complications were striate keratopathy and hyphema. (author)

  1. Parasagittal fractures of the proximal phalanx in Thoroughbred racehorses in the UK: Outcome of repaired fractures in 113 cases (2007-2011).

    Science.gov (United States)

    Smith, M R W; Corletto, F C; Wright, I M

    2017-11-01

    Thirty years have elapsed since the last published review of outcome following fracture of the proximal phalanx in Thoroughbred racehorses in the UK and contemporary results are needed to be able to advise of expected outcome. Collect and analyse outcome data following repair of fractures of the proximal phalanx in Thoroughbred racehorses in the UK. Retrospective case series. Case records of all Thoroughbred racehorses admitted to Newmarket Equine Hospital for evaluation of a parasagittal fracture of the proximal phalanx during a 5 years period were reviewed. Follow-up data regarding racing careers was collected for horses that underwent repair. Following exclusion of outliers, cases with incomplete data sets and comminuted fractures, mixed effect logistic regression was used to identify variables affecting returning to racing and odds ratios and confidence intervals calculated. Of 113 repaired cases, fracture configurations included short incomplete parasagittal (n = 12), long incomplete parasagittal (n = 86), complete parasagittal (n = 12) and comminuted (n = 3). A total of 54 (48%) cases raced after surgery. Horses that fractured at 2 years of age had increased odds of racing following surgery than those older than 2 years of age (OR 1.34; 95% CI 1.13-1.59, P = 0.002). Horses sustaining short incomplete parasagittal fractures had increased odds of racing following surgery compared with those with complete parasagittal fractures (OR 2.62; 95% CI 1.36-5.07, P = 0.006). No horses with comminuted fractures returned to racing. Data are relevant only to Thoroughbred racehorses in the UK. Approximately half of the cases in this series raced following surgical repair. More 2-year-old horses raced following surgery, but this likely reflects horses, specifically older horses, passing out of training from unrelated factors. Fracture configuration affects odds of racing, which is relevant to owners when deciding on treatment. © 2017 EVJ Ltd.

  2. Bilateral periprosthetic tibial stress fracture after total knee arthroplasty: A case report.

    Science.gov (United States)

    Ozdemir, Guzelali; Azboy, Ibrahim; Yilmaz, Baris

    2016-01-01

    Periprosthetic fractures around the knee after total knee arthroplasty can be seen in the femur, tibia and patella. The tibial fractures are rare cases. Our case with bilateral tibial stress fracture developed after total knee arthroplasty (TKA) is the first of its kind in the literature. 75-year-old male patient with bilateral knee osteoarthritis had not benefited from conservative treatment methods previously applied. Left TKA was applied. In the second month postoperatively, periprosthetic tibial fracture was identified and osteosynthesis was implemented with locked tibia proximal plate-screw. Bone union in 12 weeks was observed in his follow-ups. After 15 months of his first operation, TKA was applied to the right knee. Postoperatively in the second month, as in the first operation, periprosthetic tibial fracture was detected. Osteosynthesis with locking plate-screw was applied and union in 12 weeks was observed in his follow-up. He was seen mobilized independently and without support in the last control of the case made in the 24th month after the second operation. The number of TKA applications is expected to increase in the future. The incidence of periprosthetic fractures should also be expected to increase in these cases. Periprosthetic tibial fractures after TKA are rarely seen. The treatment of periprosthetic fractures around the knee after TKA can be difficult. In the case of persistent pain in the upper end of the tibia after the surgery, stress fracture should be considered. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Intraoperative ultrasonography for presumed brain metastases: a case series study

    Directory of Open Access Journals (Sweden)

    Helder Picarelli

    2012-10-01

    Full Text Available Brain metastases (BM are one of the most common intracranial tumors and surgical treatment can improve both the functional outcomes and patient survival, particularly when systemic disease is controlled. Image-guided BM resection using intraoperative exams, such as intraoperative ultrasound (IOUS, can lead to better surgical results. METHODS: To evaluate the use of IOUS for BM resection, 20 consecutives patients were operated using IOUS to locate tumors, identify their anatomical relationships and surgical cavity after resection. Technical difficulties, complications, recurrence and survival rates were noted. RESULTS: IOUS proved effective for locating, determining borders and defining the anatomical relationships of BM, as well as to identify incomplete tumor resection. No complications related to IOUS were seen. CONCLUSION: IOUS is a practical supporting method for the resection of BM, but further studies comparing this method with other intraoperative exams are needed to evaluate its actual contribution and reliability.

  4. Shaft-Condylar Angle for surgical correction in neglected and displaced lateral humeral condyle fracture in children.

    Science.gov (United States)

    Mulpruek, Pornchai; Angsanuntsukh, Chanika; Woratanarat, Patarawan; Sa-Ngasoongsong, Paphon; Tawonsawatruk, Tulyapruek; Chanplakorn, Pongsthorn

    2015-09-01

    To assess the outcome after using the Shaft-Condylar angle (SCA) as intraoperative reference for sagittal plane correction in displaced lateral humeral condyle fractures in children presented 3-weeks after injury. Ten children, with delayed presentation of a displaced lateral humeral condyle fracture and undergoing surgery during 1999-2011, were reviewed. The goal was to obtain a smooth articular surface with an intraoperative SCA of nearly 40° and nearest-anatomical carrying angle. They were allocated into two groups according to the postoperative SCA [Good-reduction group (SCA=30-50°), and Bad-reduction group (SCA50°)] and the final outcomes were then compared. All fractures united without avascular necrosis. The Good-reduction group (n=7) showed a significant improvement in final range of motion and functional outcome compared to the Bad-reduction group (n=3) (p=0.02). However, there was no significant difference in pain, carrying angle and overall outcome between both groups. SCA is a possible intraoperative reference for sagittal alignment correction in late presented displaced lateral humeral condyle fractures.

  5. Postpartum Sacral Stress Fracture: An Atypical Case Report

    Directory of Open Access Journals (Sweden)

    Andrea Speziali

    2015-01-01

    Full Text Available Sacral stress fractures are common in elderly people. However, sacral stress fracture should be always screened in the differential diagnoses of low back pain during the postpartum period. We present a case of sacral fracture in a thirty-six-year-old woman with low back pain and severe right buttock pain two days after cesarean section delivery of a 3.9 Kg baby. The diagnosis was confirmed by MRI and CT scan, while X-ray was unable to detect the fracture. Contribution of mechanical factors during the cesarean section is not a reasonable cause of sacral fracture. Pregnancy and lactation could be risk factors for sacral stress fracture even in atraumatic delivery such as cesarean section. Our patient had no risk factors for osteoporosis except for pregnancy and lactation. Transient or focal osteoporosis is challenging to assess and it cannot be ruled out even if serum test and mineral density are within the normal range.

  6. Use of intraoperative fluoroscopy during laparotomy to identify fragments of retained Essure microinserts: case report.

    Science.gov (United States)

    Howard, David L; Christenson, Paul J; Strickland, Julie L

    2012-01-01

    In previous case-reports of Essure microinsert perforation, the microinsert was successfully removed at laparoscopy. Herein is discussed the scenario of persistent pelvic pain over several years after an apparently successful laparoscopic retrieval of a perforating right-sided microinsert. In the interim, the patient underwent 2 unsuccessful exploratory laparotomy procedures in an attempt to retrieve additional microinsert fragments that had perforated the uterus. Successful management of Essure microinsert perforation in this patient ultimately required use of intraoperative fluoroscopy. Surgeons performing laparoscopy or laparotomy to retrieve Essure microinserts that have perforated should be aware that these are not always visible to the naked eye, and there should be a low threshold to use intraoperative fluoroscopy to ensure that all perforating fragments have been removed. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.

  7. New quantitative ultrasound techniques for bone analysis at the distal radius in hip fracture cases: differences between femoral neck and trochanteric fractures.

    Science.gov (United States)

    Horii, Motoyuki; Fujiwara, Hiroyoshi; Sakai, Ryo; Sawada, Koshiro; Mikami, Yasuo; Toyama, Syogo; Ozaki, Etsuko; Kuriyama, Nagato; Kurokawa, Masao; Kubo, Toshikazu

    2017-01-01

    Ample evidence on etiological and pathological differences between femoral neck and trochanteric fracture cases suggests the possibility of individualized treatment. There are many issues related to areal bone mineral density and other quantitative computed tomography parameters of the proximal femur. Although osteoporosis is a systemic problem, little has been reported regarding differences in bone structural parameters, including bone mineral density, between them in regions other than the proximal femur. Participants were consecutive female patients >50 years of age admitted to the Saiseikai Suita Hospital (Osaka prefecture, Japan) for their first hip fracture between January 2012 and September 2014. Cortical thickness (CoTh, mm), volumetric trabecular bone mineral density (TBD, mg/cm 3 ), and elastic modulus of trabecular bone (EMTb, GPa) were obtained as the new QUS parameters using the LD-100 system (Oyo Electric, Kyoto, Japan). The mean values of these parameters were compared between femoral neck and trochanteric fracture cases. In addition, correlations between age and each QUS parameter were investigated for each fracture type. A receiver operating characteristic (ROC) curve analysis was performed to examine the degree of effect each parameter on the fracture types. The area under the curve (AUC) for each parameter was compared to the AUC for age. There were 63 cases of femoral neck fracture (mean age, 78.2 years) and 37 cases of trochanteric fracture (mean age, 85.9 years). Mean TBD and EMTb were significantly higher for femoral neck fractures. There were significant negative correlations between QUS parameters and age for femoral neck fractures (P fractures were above those for trochanteric fractures for TBD and EMTb. AUCs were 0.72 for age, and 0.61, 0.65, and 0.65 for CoTh, TBD, and EMTb, respectively. The new QUS parameters indicated that TR fracture cases were more osteoporotic than were FN fracture cases, even at the distal radius. There might be

  8. Superior shoulder suspensory complex fracture dislocation case report

    International Nuclear Information System (INIS)

    Lidgett, T.; Bate, E.; Pittock, L.

    2017-01-01

    Background: Acromioclavicular joint dislocation can be more complex than it first appears. The presented case had an unusual combination of injuries to the superior shoulder suspensory complex, which yielded some interesting learning points. Case summary: The injuries were sustained after a fall from a push bike and included acromioclavicular dislocation with coracoid process, clavicle and acromion process fractures. These were identified on the initial X-ray examination, which was followed by computed tomography for surgical planning. The injuries were successfully treated by internal fixation. Conclusion: The unexpected complexity of the injuries could have led to subtle but important findings being overlooked. This case highlights the importance of a thorough search strategy, consideration of injury biomechanics and knowledge of associated injuries. - Highlights: • Search for associated fractures in acromioclavicular joint dislocation. • Assess the clavicle, acromion process and coracoid process in particular. • Do not end the shoulder X-ray examination after seeing one injury. • Both axial and cranially angulated anteroposterior projections are beneficial. • Acromioclavicular joint fracture dislocation treatment may require further research.

  9. Acetabular fractures following rugby tackles: a case series

    Directory of Open Access Journals (Sweden)

    Morris Seamus

    2011-10-01

    Full Text Available Abstract Introduction Rugby is the third most popular team contact sport in the world and is increasing in popularity. In 1995, rugby in Europe turned professional, and with this has come an increased rate of injury. Case presentation In a six-month period from July to December, two open reduction and internal fixations of acetabular fractures were performed in young Caucasian men (16 and 24 years old who sustained their injuries after rugby tackles. Both of these cases are described as well as the biomechanical factors contributing to the fracture and the recovery. Acetabular fractures of the hip during sport are rare occurrences. Conclusion Our recent experience of two cases over a six-month period creates concern that these high-energy injuries may become more frequent as rugby continues to adopt advanced training regimens. Protective equipment is unlikely to reduce the forces imparted across the hip joint; however, limiting 'the tackle' to only two players may well reduce the likelihood of this life-altering injury.

  10. [Treatment of pediatric distal femur fractures by external fixator combined with limited internal fixation].

    Science.gov (United States)

    Wei, Sheng-wang; Shi, Zhan-ying; Hu, Ju-zheng; Wu, Hao

    2016-03-01

    To discuss the clinical effects of external fixator combined with limited internal fixation in the treatment of pediatric distal femur fractures. From January 2008 to June 2014, 17 children of distal femur fractures were treated by external fixator combined with limited internal fixation. There were 12 males and 5 females, aged from 6 to 13 years old with an average of 10.2 years, ranged in the course of disease from 1 h to 2 d. Preoperative diagnoses were confirmed by X-ray films in all children. There were 11 patients with supracondylar fracture , and 6 patients with intercondylar comminuted fracture. According to AO/ASIF classification, 9 fractures were type A1, 5 cases were type A2,and 3 cases were type C1. The intraoperative and postoperative complications, postoperative radiological examination, lower limbs length and motion of knee joints were observed. Knee joint function was assessed by KSS score. All the patients were followed up from 6 to 38 months with an average of 24.4 months. No nerve or blood vessel injury was found. One case complicated with the external fixation loosening, 2 cases with the infection of pin hole and 3 cases with the leg length discrepancy. Knee joint mobility and length measurement (compared with the contralateral), the average limited inflexion was 10 degrees (0 degrees to 20 degrees), the average limited straight was 4 degrees (0 degrees to 10), the average varus or valgus angle was 3 degrees (0 degrees to 5 degrees). KSS of the injured side was (96.4 +/- 5.0) points at final follow-up, 16 cases got excellent results and 1 good. All fractures obtained healing and no epiphyseal closed early was found. External fixator combined with limited internal fixation has advantages of simple operation, reliable fixation, early functional exercise in treating pediatric distal femurs fractures.

  11. A biological approach to crown fracture: Fracture reattachment - A report of two cases

    Directory of Open Access Journals (Sweden)

    K Vijayaprabha

    2012-01-01

    Full Text Available The development of adhesive dentistry has allowed dentists to use the patient′s own fragment to restore the fractured tooth, which is considered to be the most conservative method of treatment of crown fracture allowing restoration of original dental anatomy, thus rehabilitating function and esthetics in a short time by preserving dental tissues. The tooth fragment reattachment is preferred over full coverage crowns or composite resin restoration because it conserves sound tooth structure, and is more esthetic, maintaining the original anatomy and translucency, and the rate of incisal wear also matches that of original tooth structure. Presented here is a report of two cases of crown fracture managed by reattachment procedures.

  12. Bilateral Traumatic Fracture of Neck of Femur in a Child: A Case Report

    Directory of Open Access Journals (Sweden)

    D Dhar

    2013-07-01

    Full Text Available Bilateral femoral neck fractures are rare in the pediatric age group, and only a few cases have been reported following major trauma in children. A 9-year old girl presented with bilateral femoral neck fractures following a motor vehicle accident. The patient was managed with early operative fixation of the fractures with a successful outcome. This case highlights the importance of awareness of the occurrence of bilateral femoral neck fractures in the polytrauma patients. This case is presented due to its rarity.

  13. Case report: bilateral ischial stress fractures in an elite tennis player

    International Nuclear Information System (INIS)

    Clarke, A.W.; Connell, D.A.

    2009-01-01

    A case report of bilateral ischial stress fractures in an elite tennis player initially mimicking hamstring pathology is described. This is an unusual site of stress fracture. Typical sites of stress fracture are well documented; however, awareness of less common sites of stress-related bone injury can aid early diagnosis and treatment before overt fracture occurs. (orig.)

  14. Case report: bilateral ischial stress fractures in an elite tennis player

    Energy Technology Data Exchange (ETDEWEB)

    Clarke, A.W.; Connell, D.A. [Royal National Orthopaedic Hospital NHS Trust, Department of Radiology, London, Middlesex (United Kingdom)

    2009-07-15

    A case report of bilateral ischial stress fractures in an elite tennis player initially mimicking hamstring pathology is described. This is an unusual site of stress fracture. Typical sites of stress fracture are well documented; however, awareness of less common sites of stress-related bone injury can aid early diagnosis and treatment before overt fracture occurs. (orig.)

  15. Transverse patella fracture in a ten year old boy: case report ...

    African Journals Online (AJOL)

    Patella fractures are rare in children. Transverse fractures in particular are an uncommon pattern. We report a case of a transverse patella fracture in a ten year old boy. He presented with inability to actively extend his left knee, two months after a fall. On evaluation he was found to have a transverse fracture of his left patella.

  16. A comparative study of the therapeutic effect between long and short intramedullary nails in the treatment of intertrochanteric femur fractures in the elderly.

    Science.gov (United States)

    Guo, Xue-Feng; Zhang, Ke-Ming; Fu, Hong-Bo; Cao, Wen; Dong, Qiang

    2015-01-01

    To compare the clinical effects of long vs. short intramedullary nails in the treatment of intertrochanteric fractures in old patients more than 65 years old. A retrospective analysis of 178 cases of intertrochanteric fractures of the femur (AO type A1 and A2) in the elderly was conducted from January 2008 to December 2013. There were 85 males (47.8%) and 93 females (52.2%) with the age of 65e89 (70.2±10.8) years. The patients were treated by closed reduction and long or short intramedullary nail (Gamma 3) fixation. The length of short nail was 180 mm and that for long nail was 320e360 mm. The general data of patients, operation time, intraoperative blood loss, length of hospital stay, preoperative hemoglobin level, blood transfusion rate, postoperative periprosthetic fractures, infections, complications, etc were carefully recorded. There were 76 cases (42.7%) in the long intramedullary nail group and 102 cases (57.3%) in the short nail group. All the cases were followed up for 12e48 (21.3±6.8) months, during which there were 21 deaths (11.8%), mean (13.8±6.9) months after operation. The intraoperative blood loss was (90.7±50.6) ml in short nail group, greatly less than that in long nail group (127.8±85.9) ml (p=0.004). The short nail group also had a significantly shorter operation time (43.5 min±12.3 min vs. 58.5 min±20.3 min, p=0.002) and lower rate of postoperative transfusion (42.3% vs. 56.7%, p=0.041). But the length of hospital stay showed no big differences. After operation, in each group there was 1 case of periprosthetic fracture with a total incidence of 1.1%, 1.3% in long nail group and 0.9% in short nail group. At the end of the follow-up, all patients achieved bony union. The average healing time of the long nail group was (6.5±3.1) months, and the short nail group was (6.8±3.7) months, revealing no significant differences (p=0.09). Postoperative complications showed no great differences either. Both the intramedullary long and short nail

  17. Paratrooper's ankle fracture: posterior malleolar fracture.

    Science.gov (United States)

    Young, Ki Won; Kim, Jin-su; Cho, Jae Ho; Kim, Hyung Seuk; Cho, Hun Ki; Lee, Kyung Tai

    2015-03-01

    We assessed the frequency and types of ankle fractures that frequently occur during parachute landings of special operation unit personnel and analyzed the causes. Fifty-six members of the special force brigade of the military who had sustained ankle fractures during parachute landings between January 2005 and April 2010 were retrospectively analyzed. The injury sites and fracture sites were identified and the fracture types were categorized by the Lauge-Hansen and Weber classifications. Follow-up surveys were performed with respect to the American Orthopedic Foot and Ankle Society ankle-hindfoot score, patient satisfaction, and return to preinjury activity. The patients were all males with a mean age of 23.6 years. There were 28 right and 28 left ankle fractures. Twenty-two patients had simple fractures and 34 patients had comminuted fractures. The average number of injury and fractures sites per person was 2.07 (116 injuries including a syndesmosis injury and a deltoid injury) and 1.75 (98 fracture sites), respectively. Twenty-three cases (41.07%) were accompanied by posterior malleolar fractures. Fifty-five patients underwent surgery; of these, 30 had plate internal fixations. Weber type A, B, and C fractures were found in 4, 38, and 14 cases, respectively. Based on the Lauge-Hansen classification, supination-external rotation injuries were found in 20 cases, supination-adduction injuries in 22 cases, pronation-external rotation injuries in 11 cases, tibiofibular fractures in 2 cases, and simple medial malleolar fractures in 2 cases. The mean follow-up period was 23.8 months, and the average follow-up American Orthopedic Foot and Ankle Society ankle-hindfoot score was 85.42. Forty-five patients (80.36%) reported excellent or good satisfaction with the outcome. Posterior malleolar fractures occurred in 41.07% of ankle fractures sustained in parachute landings. Because most of the ankle fractures in parachute injuries were compound fractures, most cases had to

  18. Early Complications in Proximal Femoral Nailing Done for Treatment of Subtrochanteric Fractures

    Directory of Open Access Journals (Sweden)

    B Kanthimathi

    2012-03-01

    Full Text Available AIM: To analyse the early complications following the use of PFN in subtrochanteric fractures. Background: Osteosynthesis with PFN in subtrochanteric fracture features the advantages of high rotational stability of the head–neck fragment, an unreamed implantation technique and the possibility of static or dynamic distal locking. However, the use of the nail requires technical expertise and is accompanied by some risks of error which can lead to osteosynthesis failure. METHODS: Between May 2009 and May 2011, 50 consecutive patients with PFN fixations for subtrochanteric fractures were observed for intraoperative and postoperative complications. RESULTS: We identified intraoperative technical difficulties in four patients and six patients showed postoperative complications. CONCLUSION: When subtrochanteric fractures are to be stabilised with a PFN, the precise and expert technical performance of implantation is the basic surgical requirement. Good reduction with minimal dissection and the use of an appropriate implant is necessary to avoid treatment failure.

  19. Sonography of occult rib and costal cartilage fractures: a case series.

    Science.gov (United States)

    Mattox, Ross; Reckelhoff, Kenneth E; Welk, Aaron B; Kettner, Norman W

    2014-06-01

    The purpose of this case series is to describe the use of diagnostic ultrasound (US) in the detection of occult rib and costal cartilage fractures presenting as chest wall pain to a chiropractic clinic. Three patients presented with chest wall pain and tenderness. Two of the patients presented with acute chest wall injury and 1 carried a previous diagnosis of rib fracture after trivial trauma 2 months earlier. Diagnostic US was selected as a non-ionizing imaging tool for these patients after negative digital radiography studies. All fractures were considered isolated as there was no associated injury, such as pneumothorax. Both of the acute cases were followed up to complete healing (evidence of osseous union) using US. All patients eventually achieved pain-free status. In these cases, US was more sensitive than radiography for diagnosing these cases of acute rib and costal cartilage fractures. Early recognition of rib injury could avoid potential complications from local manipulative therapy.

  20. Sensory impairments and wrist fractures: A case-control study

    Directory of Open Access Journals (Sweden)

    Bergthora Baldursdottir

    2017-12-01

    Full Text Available Objectives: To investigate vestibular function, foot sensation, postural control and functional abilities, and to evaluate whether these variables are associated with fall-related wrist fracture. Methods: A case-control study was conducted with 98 subjects, age range 50–75 years, who had sustained a fall-related wrist fracture. Forty-eight sex-, age- and physical activity-matched individuals, with no previous history of wrist fracture, served as controls. Measurements included: head-shake test (HST, tuning fork, biothesiometer, Semmes-Weinstein monofilaments (MF, Sensory Organization Test (SOT, Five-Times-Sit-to-Stand Test (FTSTS, 10-m walk test (10MWT, Activities-specific Balance Confidence (ABC, and the Dizziness Handicap Inventory (DHI scales. Logistic regression models were used to determine associations of variables with a fall-related wrist fracture. Results: Vestibular asymmetry was apparent in 82% of wrist fracture subjects and 63% of controls (p = 0.012. Plantar pressure sensation (p <0.001, SOT composite scores (p < 0.001, 10MWT (p <0.001, FTSTS (p <0.001, ABC (p <0.001 and DHI (p <0.005 were significantly poorer among cases than controls. A positive HST (odds ratio (OR 5.424; p = 0.008 and monofilament sensation (OR 3.886; p = 0.014 showed the strongest associations with having a fall-related wrist fracture. Conclusion: Asymmetrical vestibular function and reduced plantar pressure sensation are associated with fall-related wrist fractures among the ageing population. These factors are potential targets for future interventions.

  1. Pancreatectomy with intraoperative radiotherapy for pancreatic cancer. Implications of adjuvant radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Hishinuma, Shoichi; Ogata, Yoshiro; Ozawa, Iwao; Matsui, Junichi [Tochigi Cancer Center (Japan)

    1999-06-01

    Implications of adjuvant radiotherapy (intraoperative and postoperative) for pancreatic carcinoma were investigated. In the examination of autopsy, it was confirmed that local recurrence was controlled by irradiation, but frequency of local recurrence and liver metastasis was high, and the prognosis was poor. Local recurrence rate was 13.3% in 15 cases which had intraoperative irradiation of 30 Gy and 40% in 10 cases of irradiation under 30 Gy. After 1994, postoperative irradiation for whole liver was added to local intraoperative irradiation, and good results were obtained (10 of 19 cases are alive). Liver metastasis rate was 21.1% in whole liver irradiation group, and about 50% in other groups. Recently, local intraoperative irradiation of 30 Gy with whole liver irradiation of 22 Gy was adopted as standard adjuvant radiotherapy and better results were obtained. But it is too early to conclude their effects. (K.H.)

  2. Pancreatectomy with intraoperative radiotherapy for pancreatic cancer. Implications of adjuvant radiotherapy

    International Nuclear Information System (INIS)

    Hishinuma, Shoichi; Ogata, Yoshiro; Ozawa, Iwao; Matsui, Junichi

    1999-01-01

    Implications of adjuvant radiotherapy (intraoperative and postoperative) for pancreatic carcinoma were investigated. In the examination of autopsy, it was confirmed that local recurrence was controlled by irradiation, but frequency of local recurrence and liver metastasis was high, and the prognosis was poor. Local recurrence rate was 13.3% in 15 cases which had intraoperative irradiation of 30 Gy and 40% in 10 cases of irradiation under 30 Gy. After 1994, postoperative irradiation for whole liver was added to local intraoperative irradiation, and good results were obtained (10 of 19 cases are alive). Liver metastasis rate was 21.1% in whole liver irradiation group, and about 50% in other groups. Recently, local intraoperative irradiation of 30 Gy with whole liver irradiation of 22 Gy was adopted as standard adjuvant radiotherapy and better results were obtained. But it is too early to conclude their effects. (K.H.)

  3. Intraoperative squash smear cytology in CNS lesions: A study of 150 pediatric cases

    Directory of Open Access Journals (Sweden)

    Arpita Jindal

    2017-01-01

    Full Text Available Background: Tumors of the central nervous system in the pediatric age group occur relatively frequently during the early years of life. Brain tumors are the most common solid malignancies of childhood and only second to acute childhood leukemia. Squash cytology is an indispensable diagnostic aid to central nervous system (CNS lesions. The definitive diagnosis of brain lesions is confirmed by histological examination. Aim: To study the cytology of CNS lesions in pediatric population and correlate it with histopathology. Materials and Methods: One hundred and fifty cases of CNS lesions in pediatric patients were studied over a period of 2 years. Intraoperative squash smears were prepared, stained with hematoxylin and eosin, and examined. Remaining sample was subjected to histopathological examination. Results: Medulloblastoma (24.0% was the most frequently encountered tumor followed by pilocyctic astrocytoma (21.33% and ependymoma (13.33%. Diagnostic accuracy of squash smear technique was 94.67% when compared with histological diagnosis. Conclusion: Smear cytology is a fairly accurate tool for intraoperative CNS consultations.

  4. A three-arm (laparoscopic, hand-assisted, and robotic) matched-case analysis of intraoperative and postoperative outcomes in minimally invasive colorectal surgery.

    Science.gov (United States)

    Patel, Chirag B; Ragupathi, Madhu; Ramos-Valadez, Diego I; Haas, Eric M

    2011-02-01

    Robotic-assisted laparoscopic surgery is an emerging modality in the field of minimally invasive colorectal surgery. However, there is a dearth of data comparing outcomes with other minimally invasive techniques. We present a 3-arm (conventional, hand-assisted, and robotic) matched-case analysis of intraoperative and short-term outcomes in patients undergoing minimally invasive colorectal procedures. Between August 2008 and October 2009, 70 robotic cases of the rectum and rectosigmoid were performed. Thirty of these were organized into triplets with conventional and hand-assisted cases based on the following 6 matching criteria: 1) surgeon; 2) sex; 3) body mass index; 4) operative procedure; 5) pathology; and 6) history of neoadjuvant therapy in malignant cases. Demographics, intraoperative parameters, and postoperative outcomes were assessed. Pathological outcomes were analyzed in malignant cases. Data were stratified by postoperative diagnosis and operative procedure. There was no significant difference in intraoperative complications, estimated blood loss (126.1 ± 98.5 mL overall), or postoperative morbidity and mortality among the groups. Robotic technique required longer operative time compared with conventional laparoscopic (P hand-assisted (P robotic approach results in short-term outcomes comparable to conventional and hand-assisted laparoscopic approaches for benign and malignant diseases of the rectum and rectosigmoid. With 3-dimensional visualization, additional freedom of motion, and improved ergonomics, this enabling technology may play an important role when performing colorectal procedures involving the pelvic anatomy.

  5. Study of the X-Ray Diagnosis of Unstable Pelvic Fracture Displacements in Three-Dimensional Space and its Application in Closed Reduction.

    Science.gov (United States)

    Shi, Chengdi; Cai, Leyi; Hu, Wei; Sun, Junying

    2017-09-19

    ABSTRACTS Objective: To study the method of X-ray diagnosis of unstable pelvic fractures displaced in three-dimensional (3D) space and its clinical application in closed reduction. Five models of hemipelvic displacement were made in an adult pelvic specimen. Anteroposterior radiographs of the pelvis were analyzed in PACS. The method of X-ray diagnosis was applied in closed reductions. From February 2012 to June 2016, 23 patients (15 men, 8 women; mean age, 43.4 years) with unstable pelvic fractures were included. All patients were treated by closed reduction and percutaneous cannulate screw fixation of the pelvic ring. According to Tile's classification, the patients were classified into type B1 in 7 cases, B2 in 3, B3 in 3, C1 in 5, C2 in 3, and C3 in 2. The operation time and intraoperative blood loss were recorded. Postoperative images were evaluated by Matta radiographic standards. Five models of displacement were made successfully. The X-ray features of the models were analyzed. For clinical patients, the average operation time was 44.8 min (range, 20-90 min) and the average intraoperative blood loss was 35.7 (range, 20-100) mL. According to the Matta standards, 7 cases were excellent, 12 cases were good, and 4 were fair. The displacements in 3D space of unstable pelvic fractures can be diagnosed rapidly by X-ray analysis to guide closed reduction, with a satisfactory clinical outcome.

  6. Presurgical mapping with magnetic source imaging. Comparisons with intraoperative findings

    International Nuclear Information System (INIS)

    Roberts, T.P.L.; Ferrari, P.; Perry, D.; Rowley, H.A.; Berger, M.S.

    2000-01-01

    We compare noninvasive preoperative mapping with magnetic source imaging to intraoperative cortical stimulation mapping. These techniques were directly compared in 17 patients who underwent preoperative and postoperative somatosensory mapping of a total of 22 comparable anatomic sites (digits, face). Our findings are presented in the context of previous studies that used magnetic source imaging and functional magnetic resonance imaging as noninvasive surrogates of intraoperative mapping for the identification of sensorimotor and language-specific brain functional centers in patients with brain tumors. We found that magnetic source imaging results were reasonably concordant with intraoperative mapping findings in over 90% of cases, and that concordance could be defined as 'good' in 77% of cases. Magnetic source imaging therefore provides a viable, if coarse, identification of somatosensory areas and, consequently, can guide and reduce the time taken for intraoperative mapping procedures. (author)

  7. Avascular Necrosis of Acetabulum: The Hidden Culprit of Resistant Deep Wound Infection and Failed Fixation of Fracture Acetabulum - A Case Report.

    Science.gov (United States)

    K, Kandhari V; M, Desai M; S, Bava S; N, Wade R

    2015-01-01

    Chances of avascular necrosis of acetabulum are rare as it enjoys a rich blood supply. But cases of post - traumatic avascular necrosis of acetabulum following fracture of posterior column have been well documented. Importance of identifying and suspecting the avascular necrosis of acetabulum is essential in cases of failed fixation of fracture acetabulum, previously operated using extensile approach to acetabulum; either extended anterior ilio - femoral or tri - radiate approach. Such patients usually present with repeated deep bone infection or with early failure of fixation with aseptic loosening and migration of its components. We present a similar case. 40 years female presented with inadequately managed transverse fracture of left acetabulum done by anterior extended ilio-inguinal approach. The fixation failed. She presented 6 months later with painful hip. Cemented total hip replacement was performed with reconstruction of acetabulum by posterior column plating. Six months postoperatively patient presented with dislodgement of cup, pelvic discontinuity and sinus in the thigh. Two stage revision surgery was planned. First implant, removal; debridement and antibiotic spacer surgery was performed. At second stage of revision total hip replacement, patient had Paprosky grade IIIb defect in acetabulum. Spacer was removed through the posterior approach. Anterior approach was taken for anterior plating. Intra-operatively external iliac pulsations were found to be absent so procedure was abandoned after expert opinion. Postoperatively digital subtraction angiography demonstrated a chronic block in the external iliac artery and corona mortis was the only patent vascular channel providing vascular to the left lower limb. Thus, peripheral limb was stealing blood supply from the acetabulum to maintain perfusion. Patient was ultimately left with pelvic discontinuity, excision arthroplasty and pseudoarthrosis of the left hip. Avascular necrosis of acetabulum is a rare

  8. Clinical indications for high-field 1.5 T intraoperative magnetic resonance imaging and neuro-navigation for neurosurgical procedures. Review of initial 100 cases

    International Nuclear Information System (INIS)

    Maesawa, Satoshi; Nakahara, Norimoto; Watanabe, Tadashi; Fujii, Masazumi; Saito, Kiyoshi; Kajita, Yasukazu; Nagatani, Tetsuya; Wakabayashi, Toshihiko; Yoshida, Jun

    2009-01-01

    Initial experiences are reviewed in an integrated operation theater equipped with an intraoperative high-field (1.5 T) magnetic resonance (MR) imager and neuro-navigation (BrainSUITE), to evaluate the indications and limitations. One hundred consecutive cases were treated, consisting of 38 gliomas, 49 other tumors, 11 cerebrovascular diseases, and 2 functional diseases. The feasibility and usefulness of the integrated theater were evaluated for individual diseases, focusing on whether intraoperative images (including diffusion tensor imaging) affected the surgical strategy. The extent of resection and outcomes in each histological category of brain tumors were examined. Intraoperative high-field MR imaging frequently affected or modified the surgical strategy in the glioma group (27/38 cases, 71.1%), but less in the other tumor group (13/49 cases, 26.5%). The surgical strategy was not modified in cerebrovascular or functional diseases, but the success of procedures and the absence of complications could be confirmed. In glioma surgery, subtotal or greater resection was achieved in 22 of the 31 patients (71%) excluding biopsies, and intraoperative images revealed tumor remnants resulting in the extension of resection in 21 of the 22 patients (95.4%), the highest rate of extension among all types of pathologies. The integrated neuro-navigation improved workflow. The best indication for intraoperative high-field MR imaging and integrated neuro-navigation is brain tumors, especially gliomas, and is supplementary in assuring quality in surgery for cerebrovascular or functional diseases. Immediate quality assurance is provided in several types of neurosurgical procedures. (author)

  9. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  10. [Bilateral traumatic patella fracture: a case report].

    Science.gov (United States)

    Cırpar, Meriç; Türker, Mehmet; Aslan, Arif; Yalçınozan, Mehmet

    2011-08-01

    Patellar fractures are uncommon injuries and account for approximately 1% of all fractures. In this article, a 35-year-old male patient who sustained a collision deceleration accident with bilateral comminuted transverse patellar fractures is presented. For this patient, open reduction and internal fixation with tension band technique, using two Kirschner wires and cerclage wire was applied for both fractures. At the first postoperative day, isometric quadriceps and active range of motion exercises were begun and the patient was allowed to walk full weight bearing with two crutches while both extremities were immobilized in a hinged brace allowing maximum 30 degrees of flexion. At postoperative fourth week brace immobilization was terminated. However, the patient was advised to use crutches for two weeks more to prevent any complications that may arise during walking because of the bilaterally of the injury. At six weeks solid union was achieved. During the last visit at postoperative second year, the patient had no complaints and the range of motion was full. In this paper a case of bilateral patella fractures is presented as a consequence of a dashboard injury, and the pathomechanical and therapeutical aspects of such an injury is discussed.

  11. Cronkhite-Canada syndrome associated with rib fractures: a case report.

    Science.gov (United States)

    Yuan, Bosi; Jin, Xinxin; Zhu, Renmin; Zhang, Xiaohua; Liu, Jiong; Wan, Haijun; Lu, Heng; Shen, Yunzhu; Wang, Fangyu

    2010-10-18

    Cronkhite-Canada syndrome (CCS) is a rare multiple gastrointestinal polyposis. Up till now, many complications of CCS have been reported in the literature, but rib fracture is not included. We report a case of a 58-year-old man who was admitted to our hospital with a 6-month history of frequent diarrhea, intermittent hematochezia and a weight loss of 13 kg. On admission, physical examination revealed alopecia of the scalp, hyperpigmentation of the hands and soles, and dystrophy of the fingernails. Laboratory data revealed hypocalcaemia and hypoproteinemia. Esophagogastroduodenoscopy, video capsule endoscopy and colonoscopy revealed various sizes of generalized gastrointestinal polyps. Histological examination of the biopsy specimens obtained from the stomach and the colon showed adenomatous polyp and inflammatory polyp respectively. Thus, a diagnosis of CCS was made. After treatment with corticosteroids for 24 days and nutritional support for two months, his clinical condition improved. Two months later, he was admitted to our hospital for the second time with frequent diarrhea and weight loss. The chest radiography revealed fractures of the left sixth and seventh ribs. Examinations, including emission computed tomography, bone densitometry test, and other serum parameters, were performed, but could not identify the definite etiology of the rib fractures. One month later, the patient suffered from aggravating multiple rib fractures due to the ineffective treatment, persistent hypocalcaemia and malnutrition. This is the first case of a CCS patient with multiple rib fractures. Although the association between CCS and multiple rib fractures in this case remains uncertain, we presume that persistent hypocalcaemia and malnutrition contribute to this situation, or at least aggravate this rare complication. Besides, since prolonged corticosteroid therapy will result in an increased risk of osteoporotic fracture, CCS patients who accept corticosteroid therapy could be

  12. Fractures of the bilateral distal radius and scaphoid: a case report

    Directory of Open Access Journals (Sweden)

    Ozkan Korhan

    2008-03-01

    Full Text Available Abstract Introduction Bilateral fractures of the distal radius and scaphoid are extremely rare injuries. Case presentation A patient with bilateral comminuted, displaced distal fractures of the radius and bilateral fractures of the scaphoid was treated via internal fixation of the scaphoid fractures with Herbert screws and internal fixation of the distal radius fractures with locked volar plating. Conclusion Rigid internal fixation of distal radius and scaphoid fractures is mandatory to start early active rehabilitation of the wrist without the need for wrist immobilization with a plaster or external skeletal fixation.

  13. An unusual case of an isolated capitellar fracture of the right elbow in a child: a case report

    Directory of Open Access Journals (Sweden)

    Gonçalves Pestana José

    2012-02-01

    Full Text Available Abstract Introduction Although elbow fractures have a high incidence in the pediatric population, fractures of the capitellum are almost exclusively observed in individuals older than 12 years of age. Due to their rarity in children, reports with large numbers of cases are lacking in the literature and the surgical treatment options are poorly defined. Case presentation We present the case of an 11-year-old Portuguese girl with a displaced fracture of the capitellum of the right elbow, a typical Hahn-Steinthal or Type 1 fracture, which was followed for one year. The treatment and outcome of this fracture are described. Our patient underwent an open reduction and internal fixation with two cannulated screws. There were no complications and normal elbow function was recovered. Conclusion The authors believe that cannulated screw fixation is a reliable method of treatment for Type 1 capitellar fracture in children because it enables good interfragmentary compression, early mobilization, faster functional elbow recovery and implant removal is rarely necessary.

  14. Posterior trochanteric osteotomy in acetabular fractures for 32 cases.

    Science.gov (United States)

    Niu, Yunfei; An, Xiaofei; Xu, Shuogui; Wu, Dajiang; Zhang, Chuncai; Li, Ming

    2014-11-01

    The aim of this study is to explore the method and clinical outcome of posterior trochanteric osteotomy in acetabular fractures. From January 2000 to January 2008, 32 cases of acetabular fractures involving the dome of acetabulum underwent posterior trochanteric osteotomy for a better exposure and internal fixation with acetabular tridimensional memory fixation system. 28 cases (16 men and 12 women, mean age 39.9 years, range 16-73 years) were followed up with an average of 48.9 months (range of 19-95 months) and four were lost during follow up. Of 28 cases, 19 were fresh fractures and 9 were old fractures. The reduction was evaluated with Matta criteria. Clinical evaluation was based on modified Merle d'Aubigne and Postel scoring. Motor strength of the abductors was evaluated according to the Medical Research Council grading system. Ectopic ossification was classified according to Brooker criteria. Anatomical reduction was achieved in 17 cases and satisfied reduction in 10 patients. Poor reduction happened in an old fracture. All acetabular fractures got a direct bone union and no displacement and deep infection occurred. All osteotomies healed within 3.5 months without any nonunion, proximal migration of the greater trochanter, loosing or broken of instrumentation, and deep infection. Two superficial infections were healed with a regular dressing. Two patients underwent removal of implants from greater trochanter because of irritation. The strength of the abductors was of Grade 3/5 in two patients, Grade 4/5 in five patients, and normal in the rest. Clinical scoring was excellent to good in 84 %. Ectopic ossification occurred in five patients, grade 1 in two patients, grade 2 in two, and grade 3 in one. But function of hip joint was not seriously affected. Posterior trochanteric osteotomy can provide an adequate exposure of the dome of acetabulum without the associated complications like nonunion, proximal replacement, and weak of the abductors which often occur

  15. Algorithm of imaging modalities in cases of mandibular fractures

    International Nuclear Information System (INIS)

    Mihailova, H.

    2009-01-01

    Mandibular fracture is the most common bone fracture of maxillo-facial trauma. Up to now the main method for examination of the mandible is radiography. The aim of the issue is to present an algorithm of imaging modalities for investigation of patients in cases of mandibular trauma. It consists of series of X ray techniques and views of the facial skull named mandibulo-facial. This standardizes mandibulo-facial series includes exactly determined four projections done by conventional X ray techniques: posterior-anterior view of skull (PA or AP), oblique view of the left mandible; oblique view of the right mandible; occipito-mental view. Using these four planned radiograms is obligatory for each mandibular trauma. Panoramic X-ray is obligatory in cases of apparatus availability; this abolish only oblique views (left and right). Occipito-mental view of the skull gives anatomically better the coronoid process of the mandible, the zygoma complex, the orbital edges and maxillar sinus than Waters projection. So mandibulo-facial series of four planned radiograms is not only for diagnostic of mandibular fractures, but as a screening of mandibulo-facial trauma too. Thus using algorithm of imaging modalities in cases of mandibular fracture leads to optimization of diagnostic process in patients with mandibular trauma. (author)

  16. Comparative study of W-shaped angular plate and reconstruction plate in treating posterior wall fractures of the acetabulum.

    Directory of Open Access Journals (Sweden)

    Qi Zhang

    Full Text Available OBJECTIVE: This study aims to assess the medium-term results of the reconstruction of posterior wall fractures using a W-shaped acetabular angular plate (WAAP compared to those fixed using a reconstruction plate. METHODS: Between July 2006 and March 2009, we performed a retrospective study, which collected data for any patient treated for a posterior acetabular wall fracture. At the time of treatment, patients were either treated using a WAAP or a pelvic reconstruction plate. The intraoperative fluoroscopic images for both groups were compared. The quality of reduction and radiological grading were assessed according to the criteria developed by Matta. The clinical assessment was based on a modified Merle d'Aubigne and Postel scoring. RESULTS: 53 patients met the inclusion criteria and were followed up for an average of 38 months. 25 patients were treated with a WAAP (study group, and 28 patients were treated with a pelvic reconstruction plate (control group. The intraoperative fluoroscopic images of the study group confirmed extra-articular screw placement in all cases. In the control group, intra-articular screw placement was observed intraoperatively in 5 patients (17.86%, and the definitive location of the periarticular hardware could not be determined in 4 patients (14.29% during the operation. The differences between the two groups were statistically significant (p = 0.002. In contrast, the quality of fracture reduction, clinical outcomes, and radiological grading in the study group were not significantly different from those of the control group (p>0.05. The radiographic grade was strongly associated with the clinical outcomes in both the study and control groups (p<0.05. CONCLUSION: Reconstruction of posterior wall fractures of the acetabulum using a WAAP can help avoid screw penetration of the hip joint, provide a stable fixation of the posterior wall, and ensure good clinical outcomes.

  17. Ipsilateral femoral shaft and vertical patella fracture: a case report

    Science.gov (United States)

    Ozkan, Korhan; Eceviz, Engin; Sahin, Adem; Ugutmen, Ender

    2009-01-01

    Introduction A femoral shaft fracture with an ipsilateral patella fracture has been, to our knowledge, given only cursory attention in English-speaking literature. Case presentation A 15 year old male patient had hitten by a car to his motorcycle came to emergency room and he had been operated for his femoral shaft freacture and vertical patellar fracture which was iniatally missed. Conclusion To us it is vital to obtain CT scan of the patient’s knee if there is an ipsilateral femoral fracture with an ipsilateral knee effusion and a punction which reveals hematoma even in the absence of a fracture line seen in AP and lateral projections. PMID:19829933

  18. Research and field tests of staged fracturing technology for casing deformation sections in horizontal shale gas wells

    Directory of Open Access Journals (Sweden)

    Shimeng Liao

    2018-02-01

    Full Text Available Horizontal shale gas well fracturing is mostly carried out by pumping bridge plugs. In the case of casing deformation, the bridge plug can not be pumped down to the designated position, so the hole sections below the deformation could not be stimulated according to the design program. About 30% of horizontal shale gas wells in the Changning and Weiyuan Blocks, Sichuan Basin, suffer various casing deformation after fracturing. Previously, the hole sections which could not be stimulated due to casing deformation were generally abandoned. As a result, the resources controlled by shale gas wells weren't exploited effectively and the fracturing effect was impacted greatly. There are a lot of difficulties in investigating casing deformation, such as complex mechanisms, various influencing factors and unpredictable deformation time. Therefore, it is especially important to seek a staged fracturing technology suitable for the casing deformation sections. In this paper, the staged fracturing technology with sand plugs inside fractures and the staged fracturing technology with temporary plugging balls were tested in casing deformation wells. The staged fracturing technology with sand plugs inside fractures was carried out in the mode of single-stage perforation and single-stage fracturing. The staged fracturing technology with temporary plugging balls was conducted in the mode of single perforation, continuous fracturing and staged ball dropping. Then, two kinds of technologies were compared in terms of their advantages and disadvantages. Finally, they were tested on site. According to the pressure response, the pressure monitoring of the adjacent wells and the microseismic monitoring in the process of actual fracturing, both technologies are effective in the stimulation of the casing deformation sections, realizing well control reserves efficiently and guaranteeing fracturing effects. Keywords: Shale gas, Horizontal well, Casing deformation, Staged

  19. Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: prospective clinical study of the technique and results in ten dogs.

    Science.gov (United States)

    Cook, J L; Tomlinson, J L; Reed, A L

    1999-01-01

    To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.

  20. Vitamin D and Fracture Risk in Early Childhood: A Case-Control Study

    Science.gov (United States)

    Anderson, Laura N.; Heong, Sze Wing; Chen, Yang; Thorpe, Kevin E.; Adeli, Khosrow; Howard, Andrew; Sochett, Etienne; Birken, Catherine S.; Parkin, Patricia C.; Maguire, Jonathon L.; Abdullah, Kawsari; Anderson, Laura N.; Birken, Catherine S.; Borkhoff, Cornelia M.; Carsley, Sarah; Chen, Yang; Katz-Lavigne, Mikael; Kavikondala, Kanthi; Kowal, Christine; Maguire, Jonathon L.; Mason, Dalah; Omand, Jessica; Parkin, Patricia C.; Persaud, Navindra; van den Heuvel, Meta; Baker, Jillian; Barozzino, Tony; Bonifacio, Joey; Campbell, Douglas; Cheema, Sohail; Chisamore, Brian; Danayan, Karoon; Das, Paul; Derocher, Mary Beth; Do, Anh; Dorey, Michael; Freeman, Sloane; Fung, Keewai; Guiang, Charlie; Handford, Curtis; Hatch, Hailey; Jacobson, Sheila; Kiran, Tara; Knowles, Holly; Kwok, Bruce; Lakhoo, Sheila; Lam-Antoniades, Margarita; Lau, Eddy; Leung, Fok-Han; Loo, Jennifer; Mahmoud, Sarah; Moodie, Rosemary; Morinis, Julia; Naymark, Sharon; Neelands, Patricia; Owen, James; Peer, Michael; Perlmutar, Marty; Persaud, Navindra; Pinto, Andrew; Porepa, Michelle; Ramji, Nasreen; Ramji, Noor; Rosenthal, Alana; Saunderson, Janet; Saxena, Rahul; Sgro, Michael; Shepherd, Susan; Smiltnieks, Barbara; Taylor, Carolyn; Weisdors, Thea; Wijayasinghe, Sheila; Wong, Peter; Ying, Ethel; Young, Elizabeth

    2017-01-01

    Abstract The objective of this study was to evaluate the association of vitamin D intake and serum levels with fracture risk in children under 6 years of age. A case-control study was conducted in Toronto, Ontario, Canada. Cases were recruited from the fracture clinic at the Hospital for Sick Children, and matched controls were obtained from the TARGet Kids! primary-care research network. Controls were matched to cases on age, sex, height, and season. Fracture risk was estimated from conditional logistic regression, with adjustment for skin type, fracture history, waist circumference, outdoor free play, neighborhood income, soda consumption, and child's birth weight. A total of 206 cases were recruited during May 2009–April 2013 and matched to 343 controls. Serum 25-hydroxyvitamin D concentration (per 10-nmol/L increment: adjusted odds ratio (aOR) = 0.95, 95% confidence interval (CI): 0.88, 1.03) and intake of cow's milk (2 cups/day vs. 2 cups/day: aOR = 1.39 (95% CI: 0.85, 2.23)) were not significantly associated with reduced odds of fracture. A statistically significant association was observed between child use of vitamin D supplements and decreased odds of fracture (yes vs. no: aOR = 0.42, 95% CI: 0.25, 0.69). Vitamin D supplementation, but not serum 25-hydroxyvitamin D level or milk intake, was associated with reduced fracture risk among these healthy young children. PMID:28459987

  1. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  2. 3D printing utility for surgical treatment of acetabular fractures.

    Science.gov (United States)

    Chana Rodríguez, F; Pérez Mañanes, R; Narbona Cárceles, F J; Gil Martínez, P

    2018-05-25

    Preoperative 3D modelling enables more effective diagnosis and simulates the surgical procedure. We report twenty cases of acetabular fractures with preoperative planning performed by pre-contouring synthesis plates on a 3D printed mould obtained from a computarized tomography (CT) scan. The mould impression was made with the DaVinci 1.0 printer model (XYZ Printing). After obtaining the printed hemipelvis, we proceeded to select the implant size (pelvic Matta system, Stryker ® ) that matched the characteristics of the fracture and the approach to be used. Printing the moulds took a mean of 385minutes (322-539), and 238grams of plastic were used to print the model (180-410). In all cases, anatomic reduction was obtained and intra-operative changes were not required in the initial contouring of the plates. The time needed to perform the full osteosynthesis, once the fracture had been reduced was 16.9minutes (10-24). In one case fixed with two plates, a postoperative CT scan showed partial contact of the implant with the surface of the quadrilateral plate. In the remaining cases, the contact was complete. In conclusion, our results suggest that the use of preoperative planning, by printing 3D mirror imaging models of the opposite hemipelvis and pre-contouring plates over the mould, might effectively achieve a predefined surgical objective and reduce the inherent risks in these difficult procedures. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  3. Intraoperative Sentinel Lymph Node Evaluation

    DEFF Research Database (Denmark)

    Shaw, Richard; Christensen, Anders; Java, Kapil

    2016-01-01

    BACKGROUND: Intraoperative analysis of sentinel lymph nodes would enhance the care of early-stage oral squamous cell carcinoma (OSCC). We determined the frequency and extent of cytokeratin 19 (CK19) expression in OSCC primary tumours and surrounding tissues to explore the feasibility of a "clinic......-ready" intraoperative diagnostic test (one step nucleic acid amplification-OSNA, sysmex). METHODS: Two cohorts were assembled: cohort 1, OSCC with stage and site that closely match cases suitable for sentinel lymph node biopsy (SLNB); cohort 2, HNSCC with sufficient fresh tumour tissue available for the OSNA assay (>50......% of tumours. Discordance between different techniques indicated that OSNA was more sensitive than qRT-PCR or RNA-ISH, which in turn were more sensitive than IHC. OSNA results showed CK19 expression in 80% of primary cases, so if used for diagnosis of lymph node metastasis would lead to a false-negative result...

  4. The isolated posterior malleolar fracture and syndesmotic instability: A case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Diederik P.J. Smeeing

    Full Text Available Introduction: Ankle fractures are among the most common type of fractures in the lower extremity. A posterior malleolar fracture is frequently part of a more complex ankle fracture and only in rare cases it occurs as isolated injury. Posterior malleolar fractures often occur with associated injuries, such as a Maisonneuve fracture or with bi- or trimalleolar ligamentous injuries. Knowledge about these associated injuries is essential to prevent missed diagnoses. The aim of this article is to describe the isolated posterior malleolar fracture, the possible associated injuries, the diagnostic work-up and therapeutic consequences. Presentation of case: We present a case of a 26-year-old male patient who sustained an isolated posterior malleolar fracture with 4.5 years follow-up. Discussion: Isolated fractures of the posterior malleolus are uncommon injuries. Diagnosis, treatment and outcome can seldom be extracted from large series. However, several cases have been described in literature, which we have summarized. Conclusion: This case report and literature review shows that isolated posterior malleolar fractures might occur as part of a more complex ankle injury, in combination with a fracture of the lower leg or after high energy trauma. Physicians should be aware of these associated injuries. Diagnostic work-up should include X-rays of the knee and lower leg and a CT scan of the ankle. If diagnosed and treated properly, isolated posterior malleolar fractures have a good long-term functional outcome. Keywords: Ankle fracture, Earle’s fracture, Syndesmotic fixation, Unimalleolar fracture, Volkmann’s fracture, Posterior malleolar fracture

  5. Pygopagus Conjoined Twins: A Neurophysiologic Intraoperative Monitoring Schema.

    Science.gov (United States)

    Cromeens, Barrett P; McKinney, Jennifer L; Leonard, Jeffrey R; Governale, Lance S; Brown, Judy L; Henry, Christina M; Levitt, Marc A; Wood, Richard J; Besner, Gail E; Islam, Monica P

    2017-03-01

    Conjoined twins occur in up to 1 in 50,000 live births with approximately 18% joined in a pygopagus configuration at the buttocks. Twins with this configuration display symptoms and carry surgical risks during separation related to the extent of their connection which can include anorectal, genitourinary, vertebral, and neural structures. Neurophysiologic intraoperative monitoring for these cases has been discussed in the literature with variable utility. The authors present a case of pygopagus twins with fused spinal cords and imperforate anus where the use of neurophysiologic intraoperative monitoring significantly impacted surgical decision-making in division of these critical structures.

  6. Fracture of the penis: A report of two cases | Ugwu | Nigerian Journal ...

    African Journals Online (AJOL)

    We present two cases of fracture of the penis in two young men at the extremes of the social strata the first an unemployed tailor while the other a practicing engineer. The first one was a bachelor while the other was married with children. In the first case, the fracture occurred during masturbation while in the second case it ...

  7. Fracture of fusion mass after hardware removal in patients with high sagittal imbalance.

    Science.gov (United States)

    Sedney, Cara L; Daffner, Scott D; Stefanko, Jared J; Abdelfattah, Hesham; Emery, Sanford E; France, John C

    2016-04-01

    As spinal fusions become more common and more complex, so do the sequelae of these procedures, some of which remain poorly understood. The authors report on a series of patients who underwent removal of hardware after CT-proven solid fusion, confirmed by intraoperative findings. These patients later developed a spontaneous fracture of the fusion mass that was not associated with trauma. A series of such patients has not previously been described in the literature. An unfunded, retrospective review of the surgical logs of 3 fellowship-trained spine surgeons yielded 7 patients who suffered a fracture of a fusion mass after hardware removal. Adult patients from the West Virginia University Department of Orthopaedics who underwent hardware removal in the setting of adjacent-segment disease (ASD), and subsequently experienced fracture of the fusion mass through the uninstrumented segment, were studied. The medical records and radiological studies of these patients were examined for patient demographics and comorbidities, initial indication for surgery, total number of surgeries, timeline of fracture occurrence, risk factors for fracture, as well as sagittal imbalance. All 7 patients underwent hardware removal in conjunction with an extension of fusion for ASD. All had CT-proven solid fusion of their previously fused segments, which was confirmed intraoperatively. All patients had previously undergone multiple operations for a variety of indications, 4 patients were smokers, and 3 patients had osteoporosis. Spontaneous fracture of the fusion mass occurred in all patients and was not due to trauma. These fractures occurred 4 months to 4 years after hardware removal. All patients had significant sagittal imbalance of 13-15 cm. The fracture level was L-5 in 6 of the 7 patients, which was the first uninstrumented level caudal to the newly placed hardware in all 6 of these patients. Six patients underwent surgery due to this fracture. The authors present a case series of 7

  8. Temporary Stabilization with External Fixator in 'Tripolar' Configuration in Two Steps Treatment of Tibial Pilon Fractures.

    Science.gov (United States)

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation. Temporary stabilization with external fixator in 'tripolar' configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases.

  9. Pacemaker lead fracture associated with weightlifting: a report of two cases.

    Science.gov (United States)

    Deering, J A; Pederson, D N

    1993-12-01

    Two cases of pacemaker lead fracture associated with weight-lifting are presented. This is a rare association which has only recently been described in the literature. In both cases, the pacemaker lead was fractured between the clavicle and the first rib, suggesting crush injury. The chest X-ray, pacemaker telemetry with measurement of lead impedance, and pacemaker reprogramming were all helpful in management.

  10. Intraoperative Atelectasis Due to Endotracheal Tube Cuff Herniation: A Case Report

    Directory of Open Access Journals (Sweden)

    Hossein Madineh

    2012-09-01

    Full Text Available Endotracheal tube (ETT cuff herniation is a rare, and often difficult to diagnose, cause of bronchial obstruction. We present a case of outside cuff herniation of an endotracheal tube that caused pulmonary right lung atelectasis. A 29-year-old man ,a case of car accident with multiple fractures, was admitted to the emergency ward and transferred to the operating room(OR for open reduction and internal fixation (ORIF of all fractures .The procedures were done under general anesthesia (G/A. The past medical history of the patient did not indicate any problem. Anesthesia was induced with thiopental, atracurium and then maintained by propofol and remifentanyl infusions and 100% O2 via orally inserted ETT. The patient was positioned in left lateral decubitus position for operation. Two hours after induction of anesthesia, the oxygen saturation level dropped to 85 % and the breath sounds in the right side of the chest were weakened. The chest x-ray images showed right lung atelectasis especially in the upper lobe. The problem was disappeared after removal of the ETT. In this case, we observed that an ETT cuff herniation can be a cause of airway obstruction. If there is a decreased unilateral breath sounds, we recommend replacement or repositioning of ETT.

  11. Lumbar vertebral haemangioma causing pathological fracture, epidural haemorrhage, and cord compression: a case report and review of literature.

    Science.gov (United States)

    Vinay, S; Khan, S K; Braybrooke, J R

    2011-01-01

    Vertebral haemangiomas are recognized to be one of the commonest benign tumours of the vertebral column, occurring mostly in the thoracic spine. The vast majority of these are asymptomatic. Infrequently, these can turn symptomatic and cause neurological deficit (cord compression) through any of four reported mechanisms: (1) epidural extension; (2) expansion of the involved vertebra(e) causing spinal canal stenosis; (3) spontaneous epidural haemorrhage; (4) pathological burst fracture. Thoracic haemangiomas have been reported to be more likely to produce cord compression than lumbar haemangiomas. A forty-nine year old male with acute onset spinal cord compression from a pathological fracture in a first lumbar vertebral haemangioma. An MRI delineated the haemangioma and extent of bleeding that caused the cord compression. These were confirmed during surgery and the haematoma was evacuated. The spine was instrumented from T12 to L2, and a cement vertebroplasty was performed intra-operatively. Written consent for publication was obtained from the patient. The junctional location of the first lumbar vertebra, and the structural weakness from normal bone being replaced by the haemangioma, probably caused it to fracture under axial loading. This pathological fracture caused bleeding from the vascularized bone, resulting in cord compression.

  12. Intraoperative Tension Pneumothorax in a Patient With Remote Trauma and Previous Tracheostomy

    Directory of Open Access Journals (Sweden)

    Ana Mavarez-Martinez MD

    2016-02-01

    Full Text Available Many trauma patients present with a combination of cranial and thoracic injury. Anesthesia for these patients carries the risk of intraoperative hemodynamic instability and respiratory complications during mechanical ventilation. Massive air leakage through a lacerated lung will result in inadequate ventilation and hypoxemia and, if left undiagnosed, may significantly compromise the hemodynamic function and create a life-threatening situation. Even though these complications are more characteristic for the early phase of trauma management, in some cases, such a scenario may develop even months after the initial trauma. We report a case of a 25-year-old patient with remote thoracic trauma, who developed an intraoperative tension pneumothorax and hemodynamic instability while undergoing an elective cranioplasty. The intraoperative patient assessment was made even more challenging by unexpected massive blood loss from the surgical site. Timely recognition and management of intraoperative pneumothorax along with adequate blood replacement stabilized the patient and helped avoid an unfavorable outcome. This case highlights the risks of intraoperative pneumothorax in trauma patients, which may develop even months after injury. A high index of suspicion and timely decompression can be life saving in this type of situation.

  13. Isolated Transverse Clivus Fracture without Neurodeficit: Case Report and Review of Literature

    International Nuclear Information System (INIS)

    Akar, Ömer; Yaldiz, Can; Özdemir, Nail; Yaman, Onur; Dalbayrak, Sedat

    2015-01-01

    Clivus is a bony surface in the posterior cranial fossa, serving as the support of the brainstem and thus neighboring important structures because of its location. Skull base fractures that cannot be shown by conventional radiography can be clearly imaged by high-resolution bone window computed tomography. A 44 years-old male referred to the emergency department because of a traffic accident in the car. His only complaint was a severe neckache. His X-ray examination showed no pathology. The computed tomographic examination showed no parenchymal pathology, but a isolated transverse fracture in the clivus. The computed tomographic examination showed isolated transverse fracture in the clivus our case presented in this paper is the first case of transverse clivus fracture without additional cranial bone fracture and neurologic deficit in the literature

  14. Case report of right hamate hook fracture in a patient with previous fracture history of left hamate hook: is it hamate bipartite?

    Directory of Open Access Journals (Sweden)

    Norton Sandra

    2006-10-01

    Full Text Available Abstract Background Hamate hook fracture is a common fracture in golfers and others who play sports that involve rackets or sticks such as tennis or hockey. This patient had a previous hamate fracture in the opposing wrist along with potential features of hamate bipartite. Case presentation A 19 year old male presented with a complaint of right wrist pain on the ulnar side of the wrist with no apparent mechanism of injury. The pain came on gradually one week before being seen in the office and he reported no prior care for the complaint. His history includes traumatic left hamate hook fracture with surgical excision. Conclusion The patient was found to have marked tenderness over the hamate and with a prior fracture to the other wrist, computed tomography of the wrist was ordered revealing a fracture to the hamate hook in the right wrist. He was referred for surgical evaluation and the hook of the hamate was excised. Post-surgically, the patient was able to return to normal activity within eight weeks. This case is indicative of fracture rather than hamate bipartite. This fracture should be considered in a case of ulnar sided wrist pain where marked tenderness is noted over the hamate, especially after participation in club or racket sports.

  15. Intraoperative ultrasound in neurosurgery

    International Nuclear Information System (INIS)

    Velasco, J.; Manzanares, R.; Fernandez, L.; Hernando, A.; Ramos, M. del Mar; Garcia, R.

    1996-01-01

    The present work is a review of the major indications for intraoperative ultrasound in the field of neurosurgery, stressing the exploratory method and describing what we consider to be the most illustrative cases. We attempt to provide a thorough view of this constantly developing technique which, despite its great practical usefulness, may be being underemployed. (Author) 47 refs

  16. Repeated Stress Fractures in an Amenorrheic Marathoner: A Case Conference.

    Science.gov (United States)

    Sutton, John R.; Nilson, Karen L.

    1989-01-01

    Presents a case conference by 2 experts on the relationship between a 26-year-old marathoner's amenorrhea and her sustained unusual stress fractures in 4 ribs (plus previous similar fractures of the calcaneal, navicular, metatarsal, and tibial bones). The experts conclude that she suffers many manifestations of overtraining. (SM)

  17. Case report: clinical and postmortem findings in four cows with rib fracture

    OpenAIRE

    Braun, Ueli; Warislohner, Sonja; Hetzel, Udo; Nuss, Karl

    2017-01-01

    BACKGROUND: Published reports of rib fractures in adult cattle are limited to the occurrence of chronic rib swellings caused by calluses, which are unremarkable from a clinical standpoint, whereas studies identifying clinical signs of rib fractures were not found in a literature search. This report describes the clinical and postmortem findings in four cows with rib fractures. CASE PRESENTATION: The 13th rib was fractured in three cows and the 11th rib in the remaining cow; three fractures...

  18. Three Cases of Spine Fractures after an Airplane Crash.

    Science.gov (United States)

    Lee, Han Joo; Moon, Bong Ju; Pennant, William A; Shin, Dong Ah; Kim, Keung Nyun; Yoon, Do Heum; Ha, Yoon

    2015-10-01

    While injuries to the spine after an airplane crash are not rare, most crashes result in fatal injuries. As such, few studies exist that reported on spine fractures sustained during airplane accidents. In this report, we demonstrate three cases of spine fractures due to crash landing of a commercial airplane. Three passengers perished from injuries after the crash landing, yet most of the passengers and crew on board survived, with injuries ranging from minor to severe. Through evaluating our three spine fracture patients, it was determined that compression fracture of the spine was the primary injury related to the airplane accident. The first patient was a 20-year-old female who sustained a T6-8 compression fracture without neurologic deterioration. The second patient was a 33-year-old female with an L2 compression fracture, and the last patient was a 49-year-old male patient with a T8 compression fracture. All three patients were managed conservatively and required spinal orthotics. During the crash, each of these patients were subjected to direct, downward high gravity z-axis (Gz) force, which gave rise to load on the spine vertically, thereby causing compression fracture. Therefore, new safety methods should be developed to prevent excessive Gz force during airplane crash landings.

  19. Three Cases of Spine Fractures after an Airplane Crash

    Science.gov (United States)

    Lee, Han Joo; Moon, Bong Ju; Pennant, William A.; Shin, Dong Ah; Kim, Keung Nyun; Yoon, Do Heum

    2015-01-01

    While injuries to the spine after an airplane crash are not rare, most crashes result in fatal injuries. As such, few studies exist that reported on spine fractures sustained during airplane accidents. In this report, we demonstrate three cases of spine fractures due to crash landing of a commercial airplane. Three passengers perished from injuries after the crash landing, yet most of the passengers and crew on board survived, with injuries ranging from minor to severe. Through evaluating our three spine fracture patients, it was determined that compression fracture of the spine was the primary injury related to the airplane accident. The first patient was a 20-year-old female who sustained a T6-8 compression fracture without neurologic deterioration. The second patient was a 33-year-old female with an L2 compression fracture, and the last patient was a 49-year-old male patient with a T8 compression fracture. All three patients were managed conservatively and required spinal orthotics. During the crash, each of these patients were subjected to direct, downward high gravity z-axis (Gz) force, which gave rise to load on the spine vertically, thereby causing compression fracture. Therefore, new safety methods should be developed to prevent excessive Gz force during airplane crash landings. PMID:27169094

  20. [Application of three-dimensional printing in the operation of distal tibia fracture involving epiphyseal plate injury for teenagers].

    Science.gov (United States)

    Zhao, Jingxin; Ma, Yachang; Han, Dong; Jin, Yu

    2017-10-01

    To investigate the application value of three-dimensional (3-D) printing technology in the operation of distal tibia fracture involving epiphyseal plate injury for teenagers. The retrospective analysis was conducted on the clinical data of 16 cases of children patients with distal tibia fracture involving epiphyseal plate injury undergoing the operation by using of 3-D printing technology between January 2014 and December 2015. There were 12 males and 4 females with an age of 9-14 years (mean, 12.8 years). The causes of injury included traffic accident injury in 9 cases, heavy pound injury in 3 cases, and sport injury in 4 cases. The time from injury to operation was 3-92 hours (mean, 25.8 hours). According to Salter-Harris typing standard, the typing for epiphyseal injury was classified as type Ⅱ in 11 cases, type Ⅲ in 4 cases, and type Ⅳ in 1 case. The thin slice CT scan on the affected limb was performed before operation, and the Mimics14.0 medical software was applied for the design and the 1∶1 fracture model was printed by the 3-D printer; the stimulation of operative reduction was made in the fracture model, and bone plate, Kirschner wire, and hollow screw with the appropriate size were chosen, then the complete operative approach and method were designed and the internal fixator regimen was chosen, then the practical operation was performed based on the preoperative design regimen. The operation time was 40-68 minutes (mean, 59.1 minutes); the intraoperative blood loss was 5-102 mL (mean, 35 mL); the intraoperative fluoroscopy times was 2-6 times (mean, 2.8 times). All the patiens were followed up 12-24 months (mean, 15 months). The fracture of 15 cases reached anatomic reduction, and 1 cases had no anatomic reduction with the displaced end less than 1 mm. All the fractures reached bony union with the healing time of 2-4 months (mean, 2.6 months). There was no deep vein thrombosis, premature epiphyseal closure and oblique, or uneven ankle surface

  1. Lumbar lordosis and pars interarticularis fractures: a case-control study

    International Nuclear Information System (INIS)

    Bugg, William G.; Lewis, Mark; Juette, Arne; Cahir, John G.; Toms, Andoni P.

    2012-01-01

    The aim of this study is to examine the relationship between lumbar lordosis and pars interarticularis fractures. In this retrospective case-control study we compare the angle of lumbar lordosis and the angle of the S1 vertebral endplate (as a measure of pelvic tilt) in patients with bilateral L5 pars interarticularis fractures with age- and sex-matched control cases with normal MRI examinations of the lumbar spine. Twenty-nine cases of bilateral L5 pars interarticularis fractures with matched control-cases were identified on MRI (16 male, 13 female, age 9-63 years). The angle of lordosis was measured between the inferior L4 and superior S1 vertebral endplates on a standing lateral lumbar spine radiograph for both groups. The mean angle of lordosis about the L5 vertebra was 36.9 (SD = 6.5 ) in the pars interarticularis fracture group, and 30.1 (SD = 6.4 ) in the control group. The difference between the two groups was significant (mean difference 6.8 , Student's t test: P < 0.001). The mean angle of sacral tilt measured was 122.2 (SD = 10.16 ) for controls and 136.4 (SD = 10.86 ) for patients with pars defects. The difference in the means of 14.2 was statistically significantly different (P < 0.0001). Sacral tilt represented by a steeply angled superior endplate of S1 is associated with a significantly increased angle of lordosis, between L4 and S1, and pars fractures at L5. Steep angulation of the first sacral vertebral segment maybe the predisposing biomechanical factor that leads to pincer-like impingement of the pars interarticularis and then spondylolysis. (orig.)

  2. Lumbar lordosis and pars interarticularis fractures: a case-control study

    Energy Technology Data Exchange (ETDEWEB)

    Bugg, William G; Lewis, Mark; Juette, Arne; Cahir, John G; Toms, Andoni P [Cotman Centre, Norwich Radiology Academy, Norwich, Norfolk (United Kingdom)

    2012-07-15

    The aim of this study is to examine the relationship between lumbar lordosis and pars interarticularis fractures. In this retrospective case-control study we compare the angle of lumbar lordosis and the angle of the S1 vertebral endplate (as a measure of pelvic tilt) in patients with bilateral L5 pars interarticularis fractures with age- and sex-matched control cases with normal MRI examinations of the lumbar spine. Twenty-nine cases of bilateral L5 pars interarticularis fractures with matched control-cases were identified on MRI (16 male, 13 female, age 9-63 years). The angle of lordosis was measured between the inferior L4 and superior S1 vertebral endplates on a standing lateral lumbar spine radiograph for both groups. The mean angle of lordosis about the L5 vertebra was 36.9 (SD = 6.5 ) in the pars interarticularis fracture group, and 30.1 (SD = 6.4 ) in the control group. The difference between the two groups was significant (mean difference 6.8 , Student's t test: P < 0.001). The mean angle of sacral tilt measured was 122.2 (SD = 10.16 ) for controls and 136.4 (SD = 10.86 ) for patients with pars defects. The difference in the means of 14.2 was statistically significantly different (P < 0.0001). Sacral tilt represented by a steeply angled superior endplate of S1 is associated with a significantly increased angle of lordosis, between L4 and S1, and pars fractures at L5. Steep angulation of the first sacral vertebral segment maybe the predisposing biomechanical factor that leads to pincer-like impingement of the pars interarticularis and then spondylolysis. (orig.)

  3. Lumbar lordosis and pars interarticularis fractures: a case-control study

    Energy Technology Data Exchange (ETDEWEB)

    Bugg, William G.; Lewis, Mark; Juette, Arne; Cahir, John G.; Toms, Andoni P. [Cotman Centre, Norwich Radiology Academy, Norwich, Norfolk (United Kingdom)

    2012-07-15

    The aim of this study is to examine the relationship between lumbar lordosis and pars interarticularis fractures. In this retrospective case-control study we compare the angle of lumbar lordosis and the angle of the S1 vertebral endplate (as a measure of pelvic tilt) in patients with bilateral L5 pars interarticularis fractures with age- and sex-matched control cases with normal MRI examinations of the lumbar spine. Twenty-nine cases of bilateral L5 pars interarticularis fractures with matched control-cases were identified on MRI (16 male, 13 female, age 9-63 years). The angle of lordosis was measured between the inferior L4 and superior S1 vertebral endplates on a standing lateral lumbar spine radiograph for both groups. The mean angle of lordosis about the L5 vertebra was 36.9 (SD = 6.5 ) in the pars interarticularis fracture group, and 30.1 (SD = 6.4 ) in the control group. The difference between the two groups was significant (mean difference 6.8 , Student's t test: P < 0.001). The mean angle of sacral tilt measured was 122.2 (SD = 10.16 ) for controls and 136.4 (SD = 10.86 ) for patients with pars defects. The difference in the means of 14.2 was statistically significantly different (P < 0.0001). Sacral tilt represented by a steeply angled superior endplate of S1 is associated with a significantly increased angle of lordosis, between L4 and S1, and pars fractures at L5. Steep angulation of the first sacral vertebral segment maybe the predisposing biomechanical factor that leads to pincer-like impingement of the pars interarticularis and then spondylolysis. (orig.)

  4. The changing case-mix of hip fractures in Scotland - evidence from the Scottish Hip Fracture Audit.

    Science.gov (United States)

    Hannah, Stephen D; Ferguson, K B; Smith, R; Hutchison, J; Holt, G

    2017-11-01

    Until discontinued in 2008, the Scottish Hip Fracture Audit collected and reported on data relating to the quality of care of hip fracture patients in Scotland. In 2013, the audit was recommenced under the umbrella of the MSK Audit group, which audits high volume orthopaedic pathways across Scotland. Our aim is to report on the changes in the demographics of hip fracture patients in Scotland between 2003 and 2013. There was an increase in the proportion of male patients from 2003 to 2013 (22.4% to 29.5%; p < 0.0001). An increased percentage of hip fracture patients were admitted from their own home (63.9% to 73.1%; p < 0.0001). Both these factors have deleterious effects on the outcome, and use of necessary resources, following hip fracture. There was also an increase in the percentage of patients who were American Society of Anesthesiologists Grade 3 (52.9% to 56.4%). Over the last decade, there has been a shift in the demographics of Scotland's hip fracture patients. If hip fracture incidence increases as predicted, this potentially more-challenging case-mix will likely impact on multiple health resources.

  5. Usefulness of intraoperative ultra low-field magnetic resonance imaging in glioma surgery.

    Science.gov (United States)

    Senft, Christian; Seifert, Volker; Hermann, Elvis; Franz, Kea; Gasser, Thomas

    2008-10-01

    The aim of this study was to demonstrate the usefulness of a mobile, intraoperative 0.15-T magnetic resonance imaging (MRI) scanner in glioma surgery. We analyzed our prospectively collected database of patients with glial tumors who underwent tumor resection with the use of an intraoperative ultra low-field MRI scanner (PoleStar N-20; Odin Medical Technologies, Yokneam, Israel/Medtronic, Louisville, CO). Sixty-three patients with World Health Organization Grade II to IV tumors were included in the study. All patients were subjected to postoperative 1.5-T imaging to confirm the extent of resection. Intraoperative image quality was sufficient for navigation and resection control in both high- and low-grade tumors. Primarily enhancing tumors were best detected on T1-weighted imaging, whereas fluid-attenuated inversion recovery sequences proved best for nonenhancing tumors. Intraoperative resection control led to further tumor resection in 12 (28.6%) of 42 patients with contrast-enhancing tumors and in 10 (47.6%) of 21 patients with noncontrast-enhancing tumors. In contrast-enhancing tumors, further resection led to an increased rate of complete tumor resection (71.2 versus 52.4%), and the surgical goal of gross total removal or subtotal resection was achieved in all cases (100.0%). In patients with noncontrast-enhancing tumors, the surgical goal was achieved in 19 (90.5%) of 21 cases, as intraoperative MRI findings were inconsistent with postoperative high-field imaging in 2 cases. The use of the PoleStar N-20 intraoperative ultra low-field MRI scanner helps to evaluate the extent of resection in glioma surgery. Further tumor resection after intraoperative scanning leads to an increased rate of complete tumor resection, especially in patients with contrast-enhancing tumors. However, in noncontrast- enhancing tumors, the intraoperative visualization of a complete resection seems less specific, when compared with postoperative 1.5-T MRI.

  6. Cost analysis of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery.

    Science.gov (United States)

    Fanning, James; Fenton, Bradford; Jean, Geraldine Marie; Chae, Clara

    2011-12-01

    Prophylactic intraoperative ureteral stent placement is performed to decrease operative ureteric injury, though few data are available on the effectiveness of this procedure, and no data are available on its cost. To analyze the cost of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery. All cases of prophylactic ureteral stent placement performed in gynecologic surgery during a 1-year period were identified and retrospectively reviewed through the electronic medical records database of Summa Health System. Costs were obtained through the Healthcare Cost Accounting System. The principles of cost-effective analysis were used (ie, explicit and detailed descriptions of costs and cost-effectiveness statistics). Importantly, we evaluated cost and not charges or financial model estimates. In addition, we obtained the contribution margins (ie, the hospital's net profit or loss) for prophylactic ureteral stent placement. Other gynecologic procedures were also analyzed. Among 792 major inpatient gynecologic procedures, 18 cases of prophylactic intraoperative ureteral stents were identified. Median costs were as follows: additional cost of prophylactic intraoperative ureteral stenting, $1580; additional cost of surgical resources, $770; cost of ureteral catheters, $427; cost of surgeons, $383. The contribution margins per case for various gynecologic surgical procedures were as follows: oophorectomy, $2804 profit; abdominal hysterectomy, $2649 profit; laparoscopically assisted vaginal hysterectomy (LAVH), $1760 profit. When intraoperative ureteral stenting was added, the contribution margins changed to the following: oophorectomy, $782 profit; abdominal hysterectomy, $627 profit; LAVH, $262 loss. Overall, the contribution margin profit was decreased by about 85%, from $2400 to $380. Prophylactic intraoperative ureteral stenting in gynecologic surgery decreases a hospital's contribution margin. Because of the expense of this procedure, as well as

  7. Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report

    Directory of Open Access Journals (Sweden)

    Ji Wan Kim

    2017-05-01

    Full Text Available An 85-year-old woman developed severe swelling and pain in the proximal thigh after internal fixation of an intertrochanteric fracture of the femur with a hip nail. In order to identify the causes and determine the effective treatment, angiography was performed. The results of the angiography revealed a pseudoaneurysm of a branch of deep femoral artery. Endovascular embolization was used to treat the pseudoaneurysm. After reviewing all possible causes, we found a mistake in insertion of a guide wire for hip nail. Using intraoperative fluoroscopic images, we found the mal-positioned guide wire located posterior to trochanter on lateral view of hip. This case study reminds us that pseudoaneurysm can occur in a guide wire during hip nailing. Surgeons can avoid this complication with confirmation of lateral and anteroposterior view of hip.

  8. A comparison of locked versus nonlocked Enders rods for length unstable pediatric femoral shaft fractures.

    Science.gov (United States)

    Ellis, Henry Bone; Ho, Christine A; Podeszwa, David A; Wilson, Philip L

    2011-12-01

    Stainless steel flexible Enders rods have been used for intramedullary fixation of pediatric femur fractures with good success. Despite intraoperative anatomic alignment, length unstable femur fractures can present postoperatively with fracture shortening. The purpose of this study was to review all length unstable pediatric femoral shaft fractures in which Enders rods were used and compare those that were locked to those that were not locked. A retrospective clinical and radiographic review of all patients at a single institution undergoing flexible intramedullary fixation for length unstable femoral shaft fractures from 2001 to 2008. A length unstable fracture was defined as either a comminuted fracture or a spiral fracture longer than twice the diameter of the femoral shaft. A total of 107 length unstable femoral shaft fractures fixed with Enders rods were identified, of which 37 cases (35%) had both Enders rods "locked" through the eyelet in the distal femur with a 2.7 mm fully threaded cortical screw. Patient demographics, clinical course, complications, fracture characteristics, and radiographic outcomes were compared for the locked and nonlocked groups. There were no statistical differences between the groups in demographic data, operative variables, fracture pattern, fracture location, time to union, femoral alignment, or major complications. Shortening of the femur and nail migration measured at 1 to 6 weeks postoperatively was significantly greater for the nonlocked cases. The medial and lateral locked Enders rods moved 1.3 and 1.9 mm, respectively, and the unlocked Enders each moved 12.1 mm (P < 0.05). At final follow-up there were significantly more (P < 0.05) clinical complaints in nonlocked group, including limp, clinical shortening, and painful palpable rods. Locking Enders rods for length unstable pediatric fractures is an excellent option to prevent shortening and resulted in no additional complications, added surgical time, or increased blood loss

  9. Preoperative three-dimensional printing for surgical stabilization of rib fractures

    Directory of Open Access Journals (Sweden)

    Wei-Chun Lin

    2018-01-01

    Full Text Available Pulmonary trauma is a significant cause of morbidity and mortality in patients with major trauma. Chest wall contusion with rib fracture is very common. Surgical stabilization of rib fracture (SSRF has traditionally required an exploratory thoracotomy for adequate exposure. Minimally invasive approaches for SSRF are now being developed. However, preoperative localization of rib fractures and intraoperative designing of titanium plates require additional time. We present a novel technique involving three-dimensional printing for promoting SSRF with a minimally invasive approach that is efficient and provides good patient outcomes.

  10. A case of incomplete atypical femoral fracture with histomorphometrical evidence of osteomalacia.

    Science.gov (United States)

    Tsuchie, Hiroyuki; Miyakoshi, Naohisa; Nishi, Tomio; Abe, Hidekazu; Segawa, Toyohito; Shimada, Yoichi

    2015-01-01

    Roughly half of the femoral fracture patients diagnosed with AFF according to the criteria suggested by a task force of the American Society for Bone and Mineral Research (ASBMR) have not undergone bisphosphonate (BP) therapy. One suspected cause of such fractures is severe bone loss due to osteomalacia, but the pathogenesis remains unknown. We report a case of an 84-year-old woman with AFF not treated by BP therapy, in whom underlying osteomalacia was histologically diagnosed. The involvement of femoral curvature and spino-pelvic malaligment in the fracture in the present case was considered.

  11. Vitamin D and Fracture Risk in Early Childhood: A Case-Control Study.

    Science.gov (United States)

    Anderson, Laura N; Heong, Sze Wing; Chen, Yang; Thorpe, Kevin E; Adeli, Khosrow; Howard, Andrew; Sochett, Etienne; Birken, Catherine S; Parkin, Patricia C; Maguire, Jonathon L

    2017-06-15

    The objective of this study was to evaluate the association of vitamin D intake and serum levels with fracture risk in children under 6 years of age. A case-control study was conducted in Toronto, Ontario, Canada. Cases were recruited from the fracture clinic at the Hospital for Sick Children, and matched controls were obtained from the TARGet Kids! primary-care research network. Controls were matched to cases on age, sex, height, and season. Fracture risk was estimated from conditional logistic regression, with adjustment for skin type, fracture history, waist circumference, outdoor free play, neighborhood income, soda consumption, and child's birth weight. A total of 206 cases were recruited during May 2009-April 2013 and matched to 343 controls. Serum 25-hydroxyvitamin D concentration (per 10-nmol/L increment: adjusted odds ratio (aOR) = 0.95, 95% confidence interval (CI): 0.88, 1.03) and intake of cow's milk (2 cups/day vs. 2 cups/day: aOR = 1.39 (95% CI: 0.85, 2.23)) were not significantly associated with reduced odds of fracture. A statistically significant association was observed between child use of vitamin D supplements and decreased odds of fracture (yes vs. no: aOR = 0.42, 95% CI: 0.25, 0.69). Vitamin D supplementation, but not serum 25-hydroxyvitamin D level or milk intake, was associated with reduced fracture risk among these healthy young children. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  12. A Case of Femoral Fracture in Klippel Trenaunay Syndrome

    Directory of Open Access Journals (Sweden)

    Sam Nahas

    2014-01-01

    Full Text Available We present a case of Klippel Trenaunay syndrome (KTS who presented with severe bilateral knee osteoarthritis (OA. Preoperative planning was commenced for a total knee replacement (TKR. Whilst on the waiting list the patient suffered a fall and sustained a complete femoral diaphysis fracture. Conservative management in the form of skin traction was initially chosen as significant extra- and intramedullary vascular malformations posed an increased risk of perioperative bleeding. This failed to progress to union, and so open reduction and internal fixation was performed. This subsequently resulted in on-going delayed union, which was subsequently managed with low intensity pulsed ultrasound (LIPUS, otherwise known as Exogen (Bioventus. exogen. Secondary exogen, 2012. There are only two previous documented cases of femoral fracture in KTS. This is the first report of a patient with this rare syndrome receiving this treatment. We discuss the management of fracture in this challenging group of patients.

  13. Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study.

    Science.gov (United States)

    Anastopoulos, George; Ntagiopoulos, Panagiotis G; Chissas, Dionisios; Loupasis, George; Asimakopoulos, Antonios; Athanaselis, Eustratios; Megas, Panagiotis

    2008-10-01

    Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.

  14. Accelerated tibial fracture union in the third trimester of pregnancy: a case report

    Directory of Open Access Journals (Sweden)

    Ahmad Mudussar A

    2008-02-01

    Full Text Available Abstract Introduction We present a case of accelerated tibial fracture union in the third trimester of pregnancy. This is of particular relevance to orthopaedic surgeons, who must be made aware of the potentially accelerated healing response in pregnancy and the requirement for prompt treatment. Case presentation A 40 year old woman at 34 weeks gestational age sustained a displaced fracture of the tibial shaft. This was initially treated conservatively in plaster with view to intra-medullary nailing postpartum. Following an emergency caesarean section, the patient was able to fully weight bear without pain 4 weeks post injury, indicating clinical union. Radiographs demonstrated radiological union with good alignment and abundant callus formation. Fracture union occurred within 4 weeks, less than half the time expected for a conservatively treated tibial shaft fracture. Conclusion Long bone fractures in pregnancy require clear and precise management plans as fracture healing is potentially accelerated. Non-operative treatment is advisable provided satisfactory alignment of the fracture is achieved.

  15. Outcome of limb fracture repair in rabbits: 139 cases (2007-2015).

    Science.gov (United States)

    Sasai, Hiroshi; Fujita, Daisuke; Seto, Eiko; Denda, Yuki; Imai, Yutaro; Okamoto, Kanako; Okamura, Kensaku; Furuya, Masaru; Tani, Hiroyuki; Sasai, Kazumi

    2018-02-15

    OBJECTIVE To evaluate outcome of limb fracture repair in rabbits. DESIGN Retrospective case series. ANIMALS 139 client-owned rabbits with limb fractures treated between 2007 and 2015. PROCEDURES Medical records were reviewed for information on fracture location, fracture treatment, and time to fracture healing. RESULTS 25 rabbits had fractures involving the distal aspects of the limbs (ie, metacarpal or metatarsal bones, phalanges, and calcaneus or talus). Fractures were treated in 23 of these 25 rabbits (external coaptation, n = 17; external skeletal fixation, 4; and intramedullary pinning, 2) and healed in all 23, with a median healing time of 28 days (range, 20 to 45 days). One hundred ten rabbits had long bone fractures, and fractures were treated in 100 of the 110 (external skeletal fixation, n = 89; bone plating, 1; intramedullary pinning, 3; and external coaptation, 7). The percentage of fractures that healed was significantly lower for open (14/18) than for closed (26/26) tibial fractures and was significantly lower for femoral (19/26) and treated humeral (4/6) fractures than for radial (23/24) or closed tibial (26/26) fractures. Micro-CT was used to assess fracture realignment during external skeletal fixator application and to evaluate fracture healing. CONCLUSIONS AND CLINICAL RELEVANCE The prognosis for rabbits with limb fractures was good, with fractures healing in most rabbits following fracture repair (109/123). Micro-CT was useful in assessing fracture realignment and evaluating fracture healing.

  16. [Curative effect analysis on proximal frmoral nail antirotation for the treatment of femoral intertrochanteric fracture and integrity of lateral trochanteric wall].

    Science.gov (United States)

    Wei, Jie; Qin, De-an; Guo, Xiu-sheng

    2015-06-01

    To explore clinical efficacy and key matters for the treatment of femoral intertrochanteric fracture and integrity of lateral trochanteric wall by proximal frmoral nail antirotation (PFNA). From June 2010 to December 2012,210 femoral intertrochanteric fracture patients treated with PFNA were retrospectively analyzed, including 76 males and 134 females aged from 46 to 96 years old with an average of 71 years old. All fracture were caused by injury and classified to type I (5 cases) type II (16 cases), type III (73 cases) and type IV (116 cases) according to Evans classification. The time of getting out of bed, postoperative complications and displacement of screw blade and fracture healing were observed, Baumgaertner criteria were used to evaluate quality of fracture reduction, Harris criteria were used to evaulate hip joint function. All incisions were healed at stage I, no complications occurred except incomplete of lateral trochanteric wall patients without reconstruction, other patients could get out of bed with crutches at one week and all patients discharged from hospital at 10 days after operation. One hundred and seventy-eight patients were followed up from 3 to 17 months with an average of 10 months. One case occurred unhealed fracture displacement caused by screw blade cutting, 2 cases occurred screw blade transfomed to proximal and out femoral head, other patients obtained fracture healing at 12 to 16 weeks after operation. According to Baumgaertner criteria, 130 cases obtained good results, 45 cases acceptable, and 3 poor; while 107 cases obtained excellent results, 65 good, 3 good and 3 poor according to Harris score. PFNA with mechanical advantage of intramedullary fixation has advantsges of stable fixation, shorter operation time, minimally invasive. Satisfied clinical effects could obtained by grasping fixation principle, dealing with negative factors in operation. Intraoperative reconstruction for integrity of lateral trochanteric wall could assure

  17. Change in fracture risk and fracture pattern after bariatric surgery: nested case-control study.

    Science.gov (United States)

    Rousseau, Catherine; Jean, Sonia; Gamache, Philippe; Lebel, Stéfane; Mac-Way, Fabrice; Biertho, Laurent; Michou, Laëtitia; Gagnon, Claudia

    2016-07-27

     To investigate whether bariatric surgery increases the risk of fracture.  Retrospective nested case-control study.  Patients who underwent bariatric surgery in the province of Quebec, Canada, between 2001 and 2014, selected using healthcare administrative databases.  12 676 patients who underwent bariatric surgery, age and sex matched with 38 028 obese and 126 760 non-obese controls.  Incidence and sites of fracture in patients who had undergone bariatric surgery compared with obese and non-obese controls. Fracture risk was also compared before and after surgery (index date) within each group and by type of surgery from 2006 to 2014. Multivariate conditional Poisson regression models were adjusted for fracture history, number of comorbidities, sociomaterial deprivation, and area of residence.  Before surgery, patients undergoing bariatric surgery (9169 (72.3%) women; mean age 42 (SD 11) years) were more likely to fracture (1326; 10.5%) than were obese (3065; 8.1%) or non-obese (8329; 6.6%) controls. A mean of 4.4 years after surgery, bariatric patients were more susceptible to fracture (514; 4.1%) than were obese (1013; 2.7%) and non-obese (3008; 2.4%) controls. Postoperative adjusted fracture risk was higher in the bariatric group than in the obese (relative risk 1.38, 95% confidence interval 1.23 to 1.55) and non-obese (1.44, 1.29 to 1.59) groups. Before surgery, the risk of distal lower limb fracture was higher, upper limb fracture risk was lower, and risk of clinical spine, hip, femur, or pelvic fractures was similar in the bariatric and obese groups compared with the non-obese group. After surgery, risk of distal lower limb fracture decreased (relative risk 0.66, 0.56 to 0.78), whereas risk of upper limb (1.64, 1.40 to 1.93), clinical spine (1.78, 1.08 to 2.93), pelvic, hip, or femur (2.52, 1.78 to 3.59) fractures increased. The increase in risk of fracture reached significance only for biliopancreatic diversion.  Patients undergoing bariatric

  18. [Microsurgery assisted by intraoperative magnetic resonance imaging and neuronavigation for small lesions in deep brain].

    Science.gov (United States)

    Song, Zhi-jun; Chen, Xiao-lei; Xu, Bai-nan; Sun, Zheng-hui; Sun, Guo-chen; Zhao, Yan; Wang, Fei; Wang, Yu-bo; Zhou, Ding-biao

    2012-01-03

    To explore the practicability of resecting small lesions in deep brain by intraoperative magnetic resonance imaging (iMRI) and neuronavigator-assisted microsurgery and its clinical efficacies. A total of 42 cases with small lesions in deep brain underwent intraoperative MRI and neuronavigator-assisted microsurgery. The drifting of neuronavigation was corrected by images acquired from intraoperative MR rescanning. All lesions were successfully identified and 40 cases totally removed without mortality. Only 3 cases developed new neurological deficits post-operatively while 2 of them returned to normal neurological functions after a follow-up duration of 3 months to 2 years. The application of intraoperative MRI can effectively correct the drifting of neuronavigation and enhance the accuracy of microsurgical neuronavigation for small lesions in deep brain.

  19. The Use of Percutaneous Lumbar Fixation Screws for Bilateral Pedicle Fractures with an Associated Dislocation of a Lumbar Disc Prosthesis

    Directory of Open Access Journals (Sweden)

    William D. Harrison

    2013-01-01

    Full Text Available Study Design. Case report. Objective. To identify a safe technique for salvage surgery following complications of total disc replacement. Summary of Background Data. Lumbar total disc replacement (TDR is considered by some as the gold standard for discogenic back pain. Revision techniques for TDR and their complications are in their infancy. This case describes a successful method of fixation for this complex presentation. Methods and Results. A 48-year-old male with lumbar degenerative disc disease and no comorbidities. Approximately two weeks postoperatively for a TDR, the patient represented with acute severe back pain and the TDR polyethylene inlay was identified as dislocated anteriorly. Subsequent revision surgery failed immediately as the polyethylene inlay redislocated intraoperatively. Further radiology identified bilateral pedicle fractures, previously unseen on the plain films. The salvage fusion of L5/S1 reutilized the anterior approach with an interbody fusion cage and bone graft. The patient was then turned intraoperatively and redraped. The percutaneous pedicle screws were used to fix L5 to the sacral body via the paracoccygeal corridor. Conclusion. The robust locking screw in the percutaneous screw allowed a complete fixation of the pedicle fractures. At 3-year followup, the patient has an excellent result and has returned to playing golf.

  20. Applications of intraoperative ultrasound in the treatment of complicated cases of acute and chronic pancreatitis and pancreatic cancer – own experience

    Directory of Open Access Journals (Sweden)

    Grzegorz Ćwik

    2015-03-01

    Full Text Available Both acute and chronic inflammation of the pancreas often lead to complications that nowadays can be resolved using endoscopic and surgical procedures. In many cases, intraoperative ultrasound examination (IOUS enables correct assessment of the extent of the lesion, and allows for safe surgery, while also shortening its length. Aim of the research: At the authors’ clinic, intraoperative ultrasound is performed in daily practice. In this paper, we try to share our experiences in the application of this particular imaging technique. Research sample and methodology: Intraoperative examination conducted by a surgeon who has assessed the patient prior to surgery, which enabled the surgeon to verify the initial diagnosis. The material presented in this paper includes 145 IOUS procedures performed during laparotomy due to lesions of the pancreas, 57 of which were carried out in cases of inflammatory process. Results and conclusions: IOUS is a reliable examination tool in the evaluation of acute inflammatory lesions in the pancreas, especially during the surgery of chronic, symptomatic inflammation of the organ. The procedure allows for a correct determination of the necessary scope of the planned surgery. The examination allows for the differentiation between cystic lesions and tumors of cystic nature, dictates the correct strategy for draining, as well as validates the indications for the lesion’s surgical removal. IOUS also allows the estimation of place and scope of drainage procedures in cases of overpressure in the pancreatic ducts caused by calcification of the parenchyma or choledocholitiasis in chronic pancreatitis. In pancreatic cancer, IOUS provides a verifi cation of the local extent of tumor-like lesions, allowing for the assessment of pancreatic and lymph nodes metastasis, and indicating the presence of distant and local metastases, including the liver. IOUS signifi cantly improves the effectiveness of intraoperative BAC aspiration or

  1. Thrombotic thrombocytopenic purpura presenting with pathologic fracture: a case report.

    Science.gov (United States)

    Berber, Ilhami; Erkurt, Mehmet Ali; Kuku, Irfan; Kaya, Emin; Unlu, Serkan; Ertem, Kadir; Nizam, Ilknur

    2014-08-01

    Thrombotic thrombocytopenic purpura is an acute syndrome with abnormalities in multiple organ systems, which becomes manifest with microangiopathic hemolytic anemia and thrombocytopenia. The hereditary or acquired deficiency of ADAMTS-13 activity leads to an excess of high molecular weight von Willebrand factor multimers in plasma, leading to platelet aggregation and diffuse intravascular thrombus formation, resulting in thrombotic thrombocytopenic purpura. Thrombotic lesions occurring in TTP leads to ischemia and convulsion. Depending on the properties of the bony tissue, fractures are divided into three groups as traumatic, pathological, and stress fractures. A pathologic fracture is a broken bone caused by disease leading to weakness of the bone. This process is most commonly due to osteoporosis, but may also be due to other pathologies such as cancer, infections, inherited bone disorders, or a bone cyst. We herein report a case with a pathologic fracture due to convulsion secondary to thrombotic thrombocytopenic pupura. Thrombotic lesions occurring in TTP may lead to ischemia and convulsion, as in our patient and pathological fractures presented in our case report may occur as a result of severe muscle contractions associated with convulsive activity. Thrombotic thrombocytopenic pupura is a disease that involves many organ systems and thus may have a very wide spectrum of clinical presentations. Copyright © 2014. Published by Elsevier Ltd.

  2. Diagnostic power and pitfalls of intraoperative consultation (frozen section) in rhabdomyosarcoma.

    Science.gov (United States)

    Kurtulan, Olcay; Kösemehmetoğlu, Kemal

    2015-01-01

    Intraoperative consultation plays an important role in the management of soft tissue sarcomas, such as rhabdomyosarcoma. In this study, we aimed to draw attention to the important points during frozen section interpretation, and analyse the accuracy of frozen diagnosis in rhabdomyosarcoma patients. The cases, both diagnosed as rhabdomyosarcoma or followed with a history of rhabdomyosarcoma, and interpreted with intraoperative consultation (frozen section) between 2000 and 2013 were culled from pathology archives. The diagnoses were confirmed by desmin and myogenin, immunohistochemically. The frozen and final diagnoses were noted of 21 biopsy specimens of 19 patients. Sensitivity and specificity of intraoperative consultation were calculated regarding to the major diagnostic discrepancies leading to a change in surgical management of the patient, after exclusion of the cases deferred to paraffin section. Of the evaluated 21 biopsy material, 3 (14%) were misdiagnosed: Of the 2 false negative embryonal rhabdomyosarcoma cases, sample was not representative of the tumor, and there was chemo/radiotherapy induced changes in the other case. In the only false positively diagnosed case with a known history of rhabdomyosarcoma, inflammatory cells were misinterpreted as small round cell neoplasm. In 5 (29%) of 21 biopsies, a frozen diagnosis could not be given, and the diagnosis was deferred. Six cases (29%) were evaluated with cytological squash or imprint preparation; none of the misdiagnosed cases was evaluated with adjunct cytological preparation. Six of 8 misdiagnosed or deferred biopsies showed morphological changes secondary to radiotherapy and/or chemotherapy. Sensitivity, specificity, positive predictive value, and negative predictive value were calculated as 85%, 67%, 92% and 50%, respectively. Intraoperative consultation for rhabdomyosarcoma is a reliable tool with high sensitivity and fair specificity. Cases with treatment effect may lead to diagnostic difficulties

  3. [Intraoperative magnetic resonance imaging-guided functional neuronavigation plus intraoperative neurophysiological monitoring for microsurgical resection of lesions involving hand motor area].

    Science.gov (United States)

    Miao, Xing-lu; Chen, Zhi-juan; Yang, Wei-dong; Wang, Zeng-guang; Yu, Qing; Yue, Shu-yuan; Zhang, Jian-ning

    2013-01-15

    To explore the methods and applications of intraoperative magnetic resonance imaging (iMRI)-guided functional neuronavigation plus intraoperative neurophysiological monitoring (IONM) for microsurgical resection of lesions involving hand motor area. A total of 16 patients with brain lesions adjacent to hand motor area were recruited from January 2011 to April 2012. All of them underwent neuronavigator-assisted microsurgery. Also IONM was conducted to further map hand motor area and epileptogenic focus. High-field iMRI was employed to update the anatomical and functional imaging date and verify the extent of lesion resection. Brain shifting during the functional neuronavigation was corrected by iMRI in 5 patients. Finally, total lesion resection was achieved in 13 cases and subtotal resection in 3 cases. At Months 3-12 post-operation, hand motor function improved (n = 10) or remained unchanged (n = 6). None of them had persistent neurological deficit. The postoperative seizure improvement achieved Enge II level or above in 9 cases of brain lesions complicated with secondary epilepsy. Intraoperative MRI, functional neuronavigation and neurophysiological monitoring technique are complementary in microsurgery of brain lesions involving hand motor area. Combined use of these techniques can obtain precise location of lesions and hand motor functional structures and allow a maximum resection of lesion and minimization of postoperative neurological deficits.

  4. Multiple fractures and impaired bone metabolism in Wolfram syndrome: a case report.

    Science.gov (United States)

    Catalano, Antonino; Bellone, Federica; Cicala, Giuseppe; Giandalia, Annalisa; Morabito, Nunziata; Cucinotta, Domenico; Russo, Giuseppina Tiziana

    2017-01-01

    Wolfram Syndrome (WS) is a rare and lethal disease characterized by optic atrophy, diabetes mellitus, diabetes insipidus, and hearing loss. To date, osteoporotic related fractures have not been reported in affected patients. Here, we describe the case of a man affected by WS complicated by several bone fragility fractures. A 50-year-old Caucasian man was hospitalized because of tibia and fibula fractures. His clinical features included diabetes mellitus, diabetes insipidus, optic atrophy and deafness that were consistent with an unrecognized WS diagnosis, which was confirmed by the identification of a specific mutation in gene WFS1 encoding wolframin. Bone mineral density by phalangeal quantitative ultrasound demonstrated severe osteoporosis, with high serum levels of surrogate markers of bone turn-over. Previously unidentified rib fractures were also detected. To the best of our knowledge, this is the first report of osteoporotic related fractures in a patient affected by WS. Although no effective treatments are currently available to delay the progression of the disease, this case report suggests to evaluate fracture risk in the diagnostic work-up of WS.

  5. Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws

    Directory of Open Access Journals (Sweden)

    Ghassan Kerry

    2014-01-01

    Full Text Available Study Design: Retrospective study. Objective: The aim was to find out whether intraoperative three-dimensional imaging after transpedicular positioning of Kirschner wire (K-wire in lumbar and thoracic posterior instrumentation procedures is of benefit to the patients and if this technique is accurately enough to make a postoperative screw position control through computer tomography (CT dispensable. Patients and Methods: Lumbar and thoracic posterior instrumentation procedures conducted at our department between 2002 and 2012 were retrospectively reviewed. The patients were divided into two groups: group A, including patients who underwent intraoperative three-dimensional scan after transpedicular positioning of the K-wire and group B, including patients who underwent only intraoperative biplanar fluoroscopy. An early postoperative CT of the instrumented section was done in all cases to assess the screw position. The rate of immediate intraoperative correction of the K-wires in cases of mal-positioning, as well as the rate of postoperative screw revisions, was measured. Results: In general, 345 patients (1880 screws were reviewed and divided into two groups; group A with 225 patients (1218 screws and group B with 120 patients (662 screws. One patient (0.44% (one screw [0.082%] of group A underwent postoperative screw correction while screw revisions were necessary in 14 patients (11.7% (28 screws [4.2%] of group B. Twenty-three patients (10.2% (28 K-wires [2.3%] of group A underwent intraoperative correction due to primary intraoperative detected K-wire mal-position. None of the corrected K-wires resulted in a corresponding neurological deficit. Conclusion: Three-dimensional imaging after transpedicular K-wire positioning leads to solid intraoperative identification of misplaced K-wires prior to screw placement and reduces screw revision rates compared with conventional fluoroscopic control. When no clinical deterioration emerges, a

  6. First-rib stress fracture in two adolescent swimmers: a case report.

    Science.gov (United States)

    Low, Sara; Kern, Michael; Atanda, Alfred

    2016-01-01

    First-rib stress fractures have been described in adolescent athletes in various sports, with only one prior case report of first-rib stress fractures in an adolescent female swimmer. There is a need for research on the cause, management, and prevention of these injuries as they lead to significant morbidity and critical time away from sport for these aspiring athletes. We aimed to describe first-rib stress fractures as a potential cause for non-specific atraumatic chronic shoulder pain in adolescent swimmers and to discuss the different presentations, unique risk factors, treatment, and potential injury prevention strategies of such fractures. We discussed two such cases which were successfully treated with activity modification with restriction of all overhead activity, gradually progressive physical therapy and a return to swimming protocol. First-rib stress fractures can vary in presentation and should be in the differential diagnosis in adolescent swimmers with chronic shoulder pain. These injuries can be successfully managed with rest from overhead activities and physical therapy. Gradual return to competitive swimming can be achieved even with non-union of a first-rib stress fracture. Emphasis on balanced strength training in different muscle groups and proper swimming technique is essential to prevent these injuries.

  7. Intraoperative electrocorticography

    Directory of Open Access Journals (Sweden)

    Gabriela Alcaraz

    2017-01-01

    Full Text Available Intraoperative electrocorticography (ECoG is the recording of electrophysiological activity from electrodes placed directly on the exposed surface of brain, during surgery for epilepsy and tumor resection. The ECoG is helpful in defining the seizure onset and spread within the cortical surface and delineation of the interface between epileptogenic zones and functional cortex substance of the brain. Intraoperative ECoG is an invasive procedure, it is performed during surgery mostly commonly during awake craniotomy but at times during general anaesthesia. As most anesthetic agents will affect ECoG, they should be minimized or stopped prior to any recording. Activation of intraoperative epileptiform activity may also be required if there are no spontaneous discharges. The appropriate management of the anesthetic during the time of ECoG is critical for its success. There are limitations and some controversies to all the uses of intraoperative ECoG, thus each center will set their own indications, criteria, and protocols.

  8. Management of the proximal tibia fractures by mini external fixation: A case series of 30 cases

    Directory of Open Access Journals (Sweden)

    Samar K Biswas

    2014-01-01

    Full Text Available Background: Management of high velocity trauma is a challenging problem because of morbidity of trauma and sometime residual problems of failure of proper healing of fractures with the restriction of movements of knee, shortening, and added risk of compartment syndrome in the proximal tibia fracture. There is always risk of post-operative infection and infected non-union in extensive open surgical procedure and internal fixation. Hence, there is always look out for the middle path procedure for a solution to the above said problems with the added advantage of less hospital stay and early return to work by minimal invasive procedure and stabilization of fracture reduction by multiple K-wire fixation with a frame applied externally. Stabilization of fracture with reduced pain allows early movements of neighbouring joint knee and ankle; hence, reduces the chances of fracture diseases. With this we have been stimulated to take-up the study of managing the proximal tibia fracture by mini external fixator. Aim: The aim of this study was to manage proximal tibia fractures by mini external fixator and evaluate the results and efficacy of this method. Material and Method: A total of 30 patients having proximal tibial fractures admitted at our center between 2008 and 2010 were taken and the procedure carried out was closed manipulative reduction and stabilization with mini external fixator. All acute proximal tibia fractures including tibial plateau fractures above 17 years of age of either sex were included in the study. Fracture more than 3 weeks old were excluded from the study. Result: Out of 30 cases 13 were excellent, 14 cases good, and 3 showed fair. It was found that type 5 and 6 of Schatzker′s classification have lesser outcome type of fractures Conclusion: We have found that management of the proximal tibia fractures by mini external fixation method has a better outcome. Early mobilization of knee in the proximal tibia fractures after

  9. Sagittal fractures of the third carpal bone in horses: 12 cases (1977-1985)

    International Nuclear Information System (INIS)

    Fischer, A.T. Jr.; Stover, S.M.

    1987-01-01

    Third carpal sagittal fractures were found to be related to racing injuries in 10 of 12 horses. These fractures occurred most commonly on the medial aspect of the bone. A dorsoproximal-dorsodistal view of the carpus was required to visualize the fracture in all cases. Healing of the fracture required periods of rest of up to one year. Conservative management of these fractures resulted in return to function in 7 of 12 horses

  10. [New anterolateral approach of distal femur for treatment of distal femoral fractures].

    Science.gov (United States)

    Zhang, Bin; Dai, Min; Zou, Fan; Luo, Song; Li, Binhua; Qiu, Ping; Nie, Tao

    2013-11-01

    To assess the effectiveness of the new anterolateral approach of the distal femur for the treatment of distal femoral fractures. Between July 2007 and December 2009, 58 patients with distal femoral fractures were treated by new anterolateral approach of the distal femur in 28 patients (new approach group) and by conventional approach in 30 patients (conventional approach group). There was no significant difference in gender, age, cause of injury, affected side, type of fracture, disease duration, complication, or preoperative intervention (P > 0.05). The operation time, intraoperative blood loss, intraoperative fluoroscopy frequency, hospitalization days, and Hospital for Special Surgery (HSS) score of knee were recorded. Operation was successfully completed in all patients of 2 groups, and healing of incision by first intention was obtained; no vascular and nerves injuries occurred. The operation time and intraoperative fluoroscopy frequency of new approach group were significantly less than those of conventional approach group (P 0.05). All patients were followed up 12-36 months (mean, 19.8 months). Bone union was shown on X-ray films; the fracture healing time was (12.62 +/- 2.34) weeks in the new approach group and was (13.78 +/- 1.94) weeks in the conventional approach group, showing no significant difference (t=2.78, P=0.10). The knee HSS score at last follow-up was 94.4 +/- 4.2 in the new approach group, and was 89.2 +/- 6.0 in the conventional approach group, showing significant difference between 2 groups (t=3.85, P=0.00). New anterolateral approach of the distal femur for distal femoral fractures has the advantages of exposure plenitude, minimal tissue trauma, and early function rehabilitation training so as to enhance the function recovery of knee joint.

  11. Intraoperative Ultrasound in Patients Undergoing Transsphenoidal Surgery for Pituitary Adenoma: Systematic Review [corrected].

    Science.gov (United States)

    Marcus, Hani J; Vercauteren, Tom; Ourselin, Sebastien; Dorward, Neil L

    2017-10-01

    Transsphenoidal surgery is the gold standard for pituitary adenoma resection. However, despite advances in microsurgical and endoscopic techniques, some pituitary adenomas can be challenging to cure. We sought to determine whether, in patients undergoing transsphenoidal surgery for pituitary adenoma, intraoperative ultrasound is a safe and effective technologic adjunct. The PubMed database was searched between January 1996 and January 2016 to identify relevant publications that 1) featured patients undergoing transsphenoidal surgery for pituitary adenoma, 2) used intraoperative ultrasound, and 3) reported on safety or effectiveness. Reference lists were also checked, and expert opinions were sought to identify further publications. Ultimately, 10 studies were included, comprising 1 cohort study, 7 case series, and 2 case reports. One study reported their prototype probe malfunctioned, leading to false-positive results in 2 cases, and another study' prototype probe was too large to safely enter the sphenoid sinus in 2 cases. Otherwise, no safety issues directly related to use of intraoperative ultrasound were reported. In the only comparative study, remission occurred in 89.7% (61/68) of patients with Cushing disease in whom intraoperative ultrasound was used, compared with 83.8% (57/68) in whom it was not. All studies reported that surgeons anecdotally found intraoperative ultrasound helpful. Although there is limited and low-quality evidence available, the use of intraoperative ultrasound appears to be a safe and effective technologic adjunct to transsphenoidal surgery for pituitary adenoma. Advances in ultrasound technology may allow for more widespread use of such devices. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. [Development and clinical application of a new type of anatomical locking plate for sternoclavicular joint fracture and dislocation].

    Science.gov (United States)

    Sun, Yuanlin; Yang, Yunkang; Ge, Jianhua; Yang, Kun; Xiang, Feifan; Zhou, Ju; Liang, Jie

    2018-03-01

    To report a new type of anatomical locking plate for sternocalvicular joint, and investigate its effectiveness in treatment of sternoclavicular joint fracture and dislocation. A new type of anatomical locking plate for sternoclavicular joint was developed, which accorded with the anatomical features and biomechanical characteristics of Chinese sternoclavicular joint. By adopting the method of clinical randomized controlled study, 32 patients with the sternoclavicular joint fracture and dislocation who met the selection criteria between June 2008 and May 2015 were randomly divided into groups A and B ( n =16), and the patients were treated with new anatomic locking plate and distal radial T locking plate internal fixation, respectively. There was no significant difference between 2 groups in gender, age, injured side, body mass index, cause of injury, type of injury, the time from injury to operation, and preoperative Rockwood grading score ( P >0.05). The operation time, intraoperative blood loss, incision length, hospitalization time, and postoperative complications in 2 groups were recorded, and the effectiveness was evaluated by Rockwood grading score. The operations of 2 groups completed successfully. The operation time, intraoperative blood loss, and hospitalization time in group A were significantly less than those in group B ( P case of sternoclavicular joint pain and 2 cases of wound infection; in group B, there were 1 case of sternoclavicular joint pain, 1 case of internal fixation loosening, and 1 case of sternoclavicular joint re-dislocation; there was no significant difference in complication incidence between 2 groups ( P =1.000). The Rockwood grading scores at each time point after operation in 2 groups were significantly higher than those before operation. At 1 month after operation, the Rockwood grading score in group A was significantly higher than that in group B ( t= 2.270, P =0.031); but there was no significant difference in the Rockwood

  13. Exposure to antiepileptic drugs and the risk of hip fracture: a case-control study

    DEFF Research Database (Denmark)

    Tsiropoulos, Ioannis; Andersen, Morten; Nymark, Tine

    2008-01-01

    PURPOSE: To investigate whether the use of antiepileptic drugs (AEDs) increases the risk of hip fracture. METHODS: We performed a case-control study using data from the Funen County (population 2004: 475,000) hip fracture register. Cases (n = 7,557) were all patients admitted to county hospitals...... with a hip fracture during the period 1996-2004. Controls (n = 27,575) were frequency matched by age and gender. Information on use of AEDs, other drugs, and hospital contacts was available from local registers. Odds ratios (ORs) with 95% confidence intervals (CI) for hip fracture were estimated...

  14. COMPARATIVE STUDY BETWEEN PROXIMAL FEMORAL NAILING AND DYNAMIC HIP SCREW IN THE MANAGEMENT OF INTERTROCHANTERIC FRACTURES OF FEMUR

    Directory of Open Access Journals (Sweden)

    Penugonda Ravi Shankar

    2015-01-01

    Full Text Available AIMS AND OBJECTIVES : To determine the rate of union, complications, operative risks and functional outcomes in intertrochanteric fractures treated with DHS and PFN , To compare the results obtained and To compare the effectiveness of DHS and PFN in treatment of intertrochanteric fractures. RESULTS : In the present series of 24 cases of Intertrochanteric fractures were treated by proximal femoral nailing and dynamic hip screw, 12 cases in each. Out of 24 there were 13 male and 11 female. Minimum age was 36 years, maximum age 76 years with mean age of 59.25 years. Slip and fall accounted for 75% of cases. BOYD and GRIFFIN type II fracture accounted for 58.3% of cases. Mean duration of hospital stay was 26 days in both PFN and DHS groups. Length of incision was small 5 - 6cm in PFN group compared to 10 - 12cm in DHS group. Mean external blood loss 150ml in PFN group and 315 ml in DHS group. Mean time for full weight bearing was 11.5 weeks for PFN group and 14.3 weeks for DHS group. Radiological union was 12.3 weeks in PFN group and 15.5 weeks in DHS group. Good to excellent results were seen in 91.7% of cases in PFN group and 75% in DHS group. CONCLUSION : From the study, we consider PFN as better alternative to DHS in the treatment of intertrochanteric fractures but is technically difficult procedure and requires more expertise compared to DHS.As learning curve of PFN procedure is steep, with experience gained from each case operative time, radiation exposure and intraoperative complications can be reduced in each case of PFN

  15. Intraoperative hyperventilation vs remifentanil during electrocorticography for epilepsy surgery - a case report

    DEFF Research Database (Denmark)

    Kjaer, Troels W; Madsen, F F; Moltke, F B

    2010-01-01

    different brain regions in the same patient. METHODS: Hyperventilation and ultra short acting opioid remifentanil were used separately as intraoperative precipitatants of seizure patterns, while recording from subdural and intraventricular electrodes in a patient with temporal lobe epilepsy. Two different...... ictal onset zones appeared in response to hyperventilation and remifentanil. Both zones were resected and the patient has remained essentially seizure free for 1 year. Furthermore, this is the first description of hyperventilation used as an intraoperative seizure precipitant in human focal epilepsy....

  16. Tibial stress fractures in racing Standardbreds: 13 cases (1989-1993)

    International Nuclear Information System (INIS)

    Ruggles, A.J.; Moore, R.M.; Bertone, A.L.; Schneider, R.K.; Bailey, M.Q.

    1996-01-01

    To determine clinical signs, radiographic and scintigraphic findings, and performance outcome of racing Standardbreds with tibial stress fractures. Retrospective case series. 13 racing Standardbreds with tibial stress fractures. Information concerning clinical signs, diagnostic evaluation, and recommendations was obtained by review of the medical records. Performance information before and after diagnosis of the fracture was collected from racing records, and follow-up information was obtained from the owners or trainers by use of a telephone questionnaire. Horses with tibial stress fractures were moderately lame, and diagnosis was made by nuclear scintigraphy and radiography. Fractures were more likely to occur in 2-year-old horses than in older horses. The fracture location was unique for Standardbreds; 11 of 13 developed stress fractures in the mid-diaphysis of the tibia, whereas fractures in Thoroughbreds are usually in the proximal caudal or caudolateral cortex. Fractures occurred in young horses that had raced or were in advanced race training. All horses were treated with rest alone, and 10 of 13 horses raced after injury. The horses that raced after injury were able to return to a level of performance that was equal to or better than the level raced before injury. 8 of 10 horses established a lifetime-best winning time after injury. Tibial stress fractures are a cause of lameness in young racing Standardbreds. Diagnosis is aided by nuclear scintigraphy. The prognosis for return to previous level of performance after a tibial stress fracture is good

  17. Surgical management of fractured orthodontic mini- implant- a case report.

    Science.gov (United States)

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  18. Ability of Ultrasonography in Detection of Different Extremity Bone Fractures; a Case Series Study.

    Science.gov (United States)

    Bozorgi, Farzad; Shayesteh Azar, Massoud; Montazer, Seyed Hossein; Chabra, Aroona; Heidari, Seyed Farshad; Khalilian, Alireza

    2017-01-01

    Despite radiography being the gold standard in evaluation of orthopedic injuries, using bedside ultrasonography has several potential supremacies such as avoiding exposure to ionizing radiation, availability in pre-hospital settings, being extensively accessible, and ability to be used on the bedside. The aim of the present study is to evaluate the diagnostic accuracy of ultrasonography in detection of extremity bone fractures. This study is a case series study, which was prospectively conducted on multiple blunt trauma patients, who were 18 years old or older, had stable hemodynamic, Glasgow coma scale 15, and signs or symptoms of a possible extremity bone fracture. After initial assessment, ultrasonography of suspected bones was performed by a trained emergency medicine resident and prevalence of true positive and false negative findings were calculated compared to plain radiology. 108 patients with the mean age of 44.6 ± 20.4 years were studied (67.6% male). Analysis was done on 158 sites of fracture, which were confirmed with plain radiography. 91 (57.6%) cases were suspected to have upper extremity fracture(s) and 67 (42.4%) to have lower ones. The most frequent site of injuries were forearm (36.7%) in upper limbs and leg (27.8%) in lower limbs. Prevalence of true positive and false negative cases for fractures detected by ultrasonography were 59 (64.8%) and 32 (35.52%) for upper and 49 (73.1%) and 18 (26.9%) for lower extremities, respectively. In addition, prevalence of true positive and false negative detected cases for intra-articular fractures were 24 (48%) and 26 (52%), respectively. The present study shows the moderate sensitivity (68.3%) of ultrasonography in detection of different extremity bone fractures. Ultrasonography showed the best sensitivity in detection of femur (100%) and humerus (76.2%) fractures, respectively. It had low sensitivity in detection of in intra-articular fractures.

  19. Early Experience with Combining Awake Craniotomy and Intraoperative Navigable Ultrasound for Resection of Eloquent Region Gliomas.

    Science.gov (United States)

    Moiyadi, Aliasgar; Shetty, Prakash

    2017-03-01

    Introduction  Optimal resection of tumors in eloquent locations requires a combination of intraoperative imaging and functional monitoring during surgery. Combining awake surgery with intraoperative magnetic resonanceis logistically challenging. Navigable ultrasound (US) is a useful alternative in such cases. Methods  A total of 22 subjects with eloquent tumors were operated on (1 intended biopsy and 21 intended radical resections) using combined modality three-dimensional (3D) US and awake craniotomy with intraoperative clinical monitoring. We describe the technical details for these cases specifically addressing the feasibility of combining the two modalities. Results  US was used for resection control in 18 cases. There were technical limitations in three cases. Transient intraoperative worsening was encountered in eight, necessitating premature termination of the procedure. All patients tolerated the awake procedure well. Mean duration of the surgery was 3.2 hours. Radical resections were obtained in 14 of 18 where this was intended and in 12 of the 13 where there was no adverse intraoperative monitoring event prompting premature termination of the resection. Conclusions  Combining awake surgery with 3DUS is feasible and beneficial. It does not entail any additional surgical workflow modification or patient discomfort. This combined modality intraoperative monitoring can be beneficial for eloquent region tumors. Georg Thieme Verlag KG Stuttgart · New York.

  20. Successful deep brain stimulation surgery with intraoperative magnetic resonance imaging on a difficult neuroacanthocytosis case: case report.

    Science.gov (United States)

    Lim, Thien Thien; Fernandez, Hubert H; Cooper, Scott; Wilson, Kathryn Mary K; Machado, Andre G

    2013-07-01

    Chorea acanthocytosis is a progressive hereditary neurodegenerative disorder characterized by hyperkinetic movements, seizures, and acanthocytosis in the absence of any lipid abnormality. Medical treatment is typically limited and disappointing. We report on a 32-year-old patient with chorea acanthocytosis with a failed attempt at awake deep brain stimulation (DBS) surgery due to intraoperative seizures and postoperative intracranial hematoma. He then underwent a second DBS operation, but under general anesthesia and with intraoperative magnetic resonance imaging guidance. Marked improvement in his dystonia, chorea, and overall quality of life was noted 2 and 8 months postoperatively. DBS surgery of the bilateral globus pallidus pars interna may be useful in controlling the hyperkinetic movements in neuroacanthocytosis. Because of the high propensity for seizures in this disorder, DBS performed under general anesthesia, with intraoperative magnetic resonance imaging guidance, may allow successful implantation while maintaining accurate target localization.

  1. Total Pancreatic Fracture Due to Blunt Trauma: Report of a Rare Case

    Directory of Open Access Journals (Sweden)

    Kamil Gulpinar

    2016-05-01

    Full Text Available A rare case of pancreatic fracture due to blunt trauma was presented. The patient was 70 year old male who had a motor vehicle collision and was suspected a pancreatic trauma due his examinations with ultrasound and computerized tomography. The diagnosis of splenic injury and pancreas body total fracture in the point where the portal vein crosses the pancreatic body was made with the help of magnetic resonance cholangiopancreatography. He was taken to emergency surgery where a splenectomy and a distal pancreatectomy were performed. We represented this infrequent case of pancreatic fracture and its complications after blunt abdominal trauma and discuss the diagnostic and management practices.

  2. Anterior avulsion fracture of the tibial tuberosity in adolescents - Two case reports

    Directory of Open Access Journals (Sweden)

    Aleilimar Teixeira da Silva Júnior

    Full Text Available ABSTRACT The objective here was to report two rare cases of anterior avulsion fracture of the tibial tuberosity in adolescents. Case 1 was a 15-year-old male who became injured through landing on his left knee and presented limited extension. Case 2 was a 16-year-old basketball player who presented sudden pain in the right knee and functional incapacity, after a jump. Imaging examinations (radiographs and computed tomography showed anterior avulsion fractures of the tibial tuberosity. Surgical fixation was performed using screws and anchors, while avoiding growth plate injury. The cases evolved without lower-limb deformities.

  3. Intraoperative parathyroid hormone assay-cutting the Gordian knot

    Directory of Open Access Journals (Sweden)

    Chandralekha Tampi

    2014-01-01

    Full Text Available Background: Hyperparathyroidism is treated by surgical excision of the hyperfunctioning parathyroid gland. In case of adenoma the single abnormal gland is removed, while in hyperplasias, a subtotal excision, that is, three-and-a-half of the four glands are removed. This therapeutic decision is made intraoperatively through frozen section evaluation and is sometimes problematic, due to a histological overlap between hyperplasia and the adenoma. The intraoperative parathyroid hormone (IOPTH assay, propogated in recent years, offers an elegant solution, with a high success rate, due to its ability to identify the removal of all hyperfunctioning parathyroid tissue. Aim: To study the feasibility of using IOPTH in our setting. Materials and Methods: Seven patients undergoing surgery for primary hyperparathyroidism had their IOPTH levels evaluated, along with the routine frozen and paraffin sections. Results: All seven patients showed more than a 50% intraoperative fall in serum PTH after excision of the abnormal gland. This was indicative of an adenoma and was confirmed by histopathological examination and normalization of serum calcium postoperatively. Conclusion: The intraoperative parathyroid hormone is a sensitive and specific guide to a complete removal of the abnormal parathyroid tissue. It can be incorporated without difficulty as an intraoperative guide and is superior to frozen section diagnosis in parathyroid surgery.

  4. Case report

    African Journals Online (AJOL)

    abp

    2013-06-23

    Jun 23, 2013 ... Fracture consolidation and ability to walk without ... This is an Open Access article distributed under the terms of the ... Published in partnership with the African Field Epidemiology Network (AFENET). .... intraoperative time.

  5. Comparison of the Conventional Surgery and the Surgery Assisted by 3d Printing Technology in the Treatment of Calcaneal Fractures.

    Science.gov (United States)

    Zheng, Wenhao; Tao, Zhenyu; Lou, Yiting; Feng, Zhenhua; Li, Hang; Cheng, Liang; Zhang, Hui; Wang, Jianshun; Guo, Xiaoshan; Chen, Hua

    2017-09-19

    This study was aimed to compare conventional surgery and surgery assisted by 3D printing technology in the treatment of calcaneal fractures. In addition, we also investigated the effect of 3D printing technology on the communication between doctors and patients. we enrolled 75 patients with calcaneal fracture from April 2014 to August 2016. They were divided randomly into two groups: 35 cases of 3D printing group, 40 cases of conventional group. The individual models were used to simulate the surgical procedures and carry out the surgery according to plan in 3D printing group. Operation duration, blood loss volume during the surgery, number of intraoperative fluoroscopy and fracture union time were recorded. The radiographic outcomes Böhler angle, Gissane angle, calcaneal width and calcaneal height and final functional outcomes including VAS and AOFAS score as well as the complications were also evaluated. Besides, we made a simple questionnaire to verify the effectiveness of the 3D-printed model for both doctors and patients. The operation duration, blood loss volume and number of intraoperative fluoroscopy for 3D printing group was 71.4 ± 6.8 minutes, 226.1 ± 22.6 ml and 5.6 ± 1.9 times, and for conventional group was 91.3 ± 11.2 minutes, 288.7 ± 34.8 ml and 8.6 ± 2.7 times respectively. There was statistically significant difference between the conventional group and 3D printing group (p 3D printing group achieved significantly better radiographic results than conventional group both postoperatively and at the final follow-up (p 3D printing model. This study suggested the clinical feasibility of 3D printing technology in treatment of calcaneal fractures.

  6. Navigation system for robot-assisted intra-articular lower-limb fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Köhler, Paul; Morad, Samir; Atkins, Roger; Dogramadzi, Sanja

    2016-10-01

    In the surgical treatment for lower-leg intra-articular fractures, the fragments have to be positioned and aligned to reconstruct the fractured bone as precisely as possible, to allow the joint to function correctly again. Standard procedures use 2D radiographs to estimate the desired reduction position of bone fragments. However, optimal correction in a 3D space requires 3D imaging. This paper introduces a new navigation system that uses pre-operative planning based on 3D CT data and intra-operative 3D guidance to virtually reduce lower-limb intra-articular fractures. Physical reduction in the fractures is then performed by our robotic system based on the virtual reduction. 3D models of bone fragments are segmented from CT scan. Fragments are pre-operatively visualized on the screen and virtually manipulated by the surgeon through a dedicated GUI to achieve the virtual reduction in the fracture. Intra-operatively, the actual position of the bone fragments is provided by an optical tracker enabling real-time 3D guidance. The motion commands for the robot connected to the bone fragment are generated, and the fracture physically reduced based on the surgeon's virtual reduction. To test the system, four femur models were fractured to obtain four different distal femur fracture types. Each one of them was subsequently reduced 20 times by a surgeon using our system. The navigation system allowed an orthopaedic surgeon to virtually reduce the fracture with a maximum residual positioning error of [Formula: see text] (translational) and [Formula: see text] (rotational). Correspondent physical reductions resulted in an accuracy of 1.03 ± 0.2 mm and [Formula: see text], when the robot reduced the fracture. Experimental outcome demonstrates the accuracy and effectiveness of the proposed navigation system, presenting a fracture reduction accuracy of about 1 mm and [Formula: see text], and meeting the clinical requirements for distal femur fracture reduction procedures.

  7. Temporary Stabilization with External Fixator in ‘Tripolar’ Configuration in Two Steps Treatment of Tibial Pilon Fractures

    Science.gov (United States)

    Daghino, Walter; Messina, Marco; Filipponi, Marco; Alessandro, Massè

    2016-01-01

    Background: The tibial pilon fractures represent a complex therapeutic problem for the orthopedic surgeon, given the frequent complications and outcomes disabling. The recent medical literature indicates that the best strategy to reduce amount of complications in tibial pilon fractures is two-stages procedure. We describe our experience in the primary stabilization of these fractures. Methods: We treated 36 cases with temporary external fixation in a simple configuration, called "tripolar": this is an essential structure (only three screws and three rods), that is possible to perform even without the availability of X-rays and with simple anesthesia or sedation. Results: We found a sufficient mechanical stability for the nursing post-operative, in absence of intraoperative and postoperative problems. The time between trauma and temporary stabilization ranged between 3 and 144 hours; surgical average time was 8.4 minutes. Definitive treatment was carried out with a delay of a minimum of 4 and a maximum of 15 days from the temporary stabilization, always without problems, both in case of ORIF (open reduction, internal fixation) or circular external fixation Conclusion: Temporary stabilization with external fixator in ‘tripolar’ configuration seems to be the most effective strategy in two steps treatment of tibial pilon fractures. These preliminary encouraging results must be confirmed by further studies with more cases. PMID:27123151

  8. Birth-related mid-posterior rib fractures in neonates: a report of three cases (and a possible fourth case) and a review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, Rick R. van [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam Zuid-Oost (Netherlands); Bilo, Rob A.C. [Netherlands Forensic Institute, Department of Forensic Pathology, Amsterdam (Netherlands); Robben, Simon G.F. [Maastricht University Medical Centre, Department of Radiology, Maastricht (Netherlands)

    2009-01-15

    Posterior rib fractures in young children have a high positive predictive value for non-accidental injury (NAI). Combined data of five studies on birth trauma (115,756 live births) showed no cases of rib fractures resulting from birth trauma. There have, however, been sporadic cases reported in the literature. We present three neonates with both posterior rib fractures and ipsilateral clavicular fractures resulting from birth trauma. A review of the literature is also presented. The common denominator and a possible mechanical aetiology are discussed. In total, 13 cases of definitive birth-related posterior rib fractures were identified. Nearly all (9/10) posterior rib fractures were (as far as reported in the original publications) in the midline. In 12 of the 13 children, birth weight was high and in 7 children birth was complicated by shoulder dystocia. An interesting finding was that in cases where a clavicular fracture was present, this was on the ipsilateral side. Radiologists, when presented with a neonate with posterior rib fractures, should be aware of this rare differential diagnosis. (orig.)

  9. Birth-related mid-posterior rib fractures in neonates: a report of three cases (and a possible fourth case) and a review of the literature

    International Nuclear Information System (INIS)

    Rijn, Rick R. van; Bilo, Rob A.C.; Robben, Simon G.F.

    2009-01-01

    Posterior rib fractures in young children have a high positive predictive value for non-accidental injury (NAI). Combined data of five studies on birth trauma (115,756 live births) showed no cases of rib fractures resulting from birth trauma. There have, however, been sporadic cases reported in the literature. We present three neonates with both posterior rib fractures and ipsilateral clavicular fractures resulting from birth trauma. A review of the literature is also presented. The common denominator and a possible mechanical aetiology are discussed. In total, 13 cases of definitive birth-related posterior rib fractures were identified. Nearly all (9/10) posterior rib fractures were (as far as reported in the original publications) in the midline. In 12 of the 13 children, birth weight was high and in 7 children birth was complicated by shoulder dystocia. An interesting finding was that in cases where a clavicular fracture was present, this was on the ipsilateral side. Radiologists, when presented with a neonate with posterior rib fractures, should be aware of this rare differential diagnosis. (orig.)

  10. A Feasibility Study into the Use of Three-Dimensional Printer Modelling in Acetabular Fracture Surgery

    Directory of Open Access Journals (Sweden)

    A. W. Yu

    2015-01-01

    Full Text Available There are a number of challenges associated with the operative treatment of acetabular fractures. The approach used is often extensive, while operative time and perioperative blood loss can also be significant. With the proliferation of 3D printer technology, we present a fast and economical way to aid the operative planning of complex fractures. We used augmented stereoscopic 3D CT reconstructions to allow for an appreciation of the normal 3D anatomy of the pelvis on the fractured side and to use the models for subsequent intraoperative contouring of pelvic reconstruction plates. This leads to a reduction in the associated soft tissue trauma, reduced intraoperative time and blood loss, minimal handling of the plate, and reduced fluoroscopic screening times. We feel that the use of this technology to customize implants, plates, and the operative procedure to a patient’s unique anatomy can only lead to improved outcomes.

  11. Low-field magnetic resonance imaging for intraoperative use in neurosurgery: a 5-year experience

    International Nuclear Information System (INIS)

    Nimsky, Christopher; Ganslandt, Oliver; Buchfelder, Michael; Fahlbusch, Rudolf; Tomandl, Bernd

    2002-01-01

    The aim of this study was to evaluate the feasibility and point out the indications of intraoperative MR imaging in neurosurgical procedures. The MR imaging was performed using a 0.2-T scanner which was located in a radiofrequency-shielded operating theater. Three major setups for intraoperative imaging were possible: inside the scanner; at the 5-Gauss line; or in an adjacent operating theater. Additionally, in lesions adjacent to eloquent brain areas microscope- and pointer-based neuronavigation with integrated functional data was applied. Three hundred ten patients were investigated in the previous 5 years, among them gliomas (n=95), pituitary tumors (n=81), and 39 non-lesional cases in whom resective or disconnective epilepsy surgery was carried out. We did not observe any adverse effects due to intraoperative MR imaging. Image quality was sufficient to evaluate the extent of the tumor resection in the majority of cases. The main indications for intraoperative MR imaging were the evaluation of the extent of a resection in glioma, ventricular tumor, pituitary tumor, and in epilepsy surgery. Intraoperative MR imaging offers the possibility of further tumor removal during the same surgical procedure in case of tumor remnants, increasing the rate of complete tumor removal. Furthermore, the effects of brain shift, which would lead to inaccurate neuronavigation, can be compensated for by an update of the neuronavigation system with intraoperative MR image data. (orig.)

  12. Double segmental tibial fractures - an unusual fracture pattern

    Directory of Open Access Journals (Sweden)

    Bali Kamal

    2012-02-01

    Full Text Available 【Abstract】A case of a 50-year-old pedestrian who was hit by a bike and suffered fractures of both bones of his right leg was presented. Complete clinical and radiographic assessment showed double segmental fractures of the tibia and multisegmental fractures of the fibula. Review of the literature revealed that this fracture pattern was unique and only a single case was reported so far. Moreover, we discussed the possible mechanisms which can lead to such an injury. We also discussed the management of segmental tibial fracture and the difficulties encountered with them. This case was managed by modern osteosynthesis tech- nique with a pleasing outcome. Key words: Fracture, bone; Tibia; Fibula; Nails

  13. The forgotten coracoid: A case report of a coracoid fracture in a male ...

    African Journals Online (AJOL)

    A fall onto the shoulder is a common mechanism of injury in cyclists. However, coracoid fractures remain unreported in the literature in this population. These authors report a case of a coracoid fracture missed on the initial plain film radiographs. Whilst these fractures can be easily missed on standard trauma series ...

  14. Prevention of intraoperative cerebrospinal fluid leaks by lumbar cerebrospinal fluid drainage during surgery for pituitary macroadenomas.

    Science.gov (United States)

    Mehta, Gautam U; Oldfield, Edward H

    2012-06-01

    Cerebrospinal fluid leakage is a major complication of transsphenoidal surgery. An intraoperative CSF leak, which occurs in up to 50% of pituitary tumor cases, is the only modifiable risk factor for postoperative leaks. Although several techniques have been described for surgical repair when an intraoperative leak is noted, none has been proposed to prevent an intraoperative CSF leak. The authors postulated that intraoperative CSF drainage would diminish tension on the arachnoid, decrease the rate of intraoperative CSF leakage during surgery for larger tumors, and reduce the need for surgical repair of CSF leaks. The results of 114 transsphenoidal operations for pituitary macroadenoma performed without intraoperative CSF drainage were compared with the findings from 44 cases in which a lumbar subarachnoid catheter was placed before surgery to drain CSF at the time of dural exposure and tumor removal. Cerebrospinal fluid drainage reduced the rate of intraoperative CSF leakage from 41% to 5% (p drainage reduced the need for operative repair (from 32% to 5%, p drainage during transsphenoidal surgery for macroadenomas reduces the rate of intraoperative CSF leaks. This preventative measure obviated the need for surgical repair of intraoperative CSF leaks using autologous fat graft placement, other operative techniques, postoperative lumbar drainage, and/or reoperation in most patients and is associated with minimal risks.

  15. Cerebral oximetry during preoperative resuscitation in elderly patients with hip fracture

    DEFF Research Database (Denmark)

    Clemmesen, C G; Pedersen, L M; Hougaard, S

    2018-01-01

    This study explores the association between postadmission and intraoperative cerebral oxygenation (ScO2), reflecting systemic perfusion, and postoperative mortality and delirium. Forty elderly (age > 65 years) patients with hip fractures were included in this prospective observational study. The ...

  16. To evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures: A prospective study.

    Science.gov (United States)

    Bali, Rishi K; Sharma, Parveen; Jindal, Shalu; Gaba, Shivani

    2013-07-01

    The present study was undertaken to evaluate the efficacy of biodegradable plating system for fixation of maxillofacial fractures and to study the morbidity associated with the use of biodegradable plates and screws. This prospective study consisted of 10 patients with maxillofacial fractures requiring open reduction and internal fixation. Fractures with infection, comminuted and pathological fractures were excluded. All were plated with biodegradable system (Inion CPS) using standard plating principles and observed for a total period of 24 weeks. Characteristics of the fractures, ease of use of bioresorbable plate/screw system and post operative complications were assessed. Of total 10 patients, eight patients were of midface fracture and two pediatric patients with mandibular fracture, with nine male and one female. The mean age was 32.8 years. Out of 20 plates and 68 screws applied to the 10 fractures sites; there were three incidences of screw breakage with no other intraoperative difficulties. Paresthesia of the infraorbital nerve was present in two patients, and recovered completely in four weeks after surgery. Fracture reduction was considered to be satisfactory in all cases. One patient developed postsurgical infection and was managed with oral antibiotics and analgesics. Favorable healing can be observed through the use of biodegradable plates and screws to stabilize selected midface fractures in patients of all ages, as well as mandible fractures in early childhood, however further studies with more sample size are required.

  17. The effect of aspirin on blood loss and transfusion requirements in patients with femoral neck fractures.

    LENUS (Irish Health Repository)

    Manning, Brian J

    2012-02-03

    Although it is widely accepted that aspirin will increase the risk of intra- and post-operative bleeding, clinical studies have not consistently supported this assumption. We aimed to assess the effect of pre-operative aspirin on blood loss and transfusion requirements in patients undergoing emergency fixation of femoral neck fractures. A prospective case-control study was undertaken in patients presenting with femoral neck fractures. Parameters recorded included intra-operative blood loss, post-operative blood loss, transfusion requirements and peri-operative reduction in haemoglobin concentration. Of 89 patients presenting with femoral neck fractures 32 were on long-term aspirin therapy. Pre-operative aspirin ingestion did not significantly affect peri-operative blood loss, or change in haemoglobin concentration or haematocrit. However those patients taking aspirin pre-operatively had a significantly lower haemoglobin concentration and haematocrit and were more likely to be anaemic at presentation than those who were not receiving aspirin. Patients taking aspirin were also more likely to receive blood transfusion post-operatively.

  18. Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures.

    Science.gov (United States)

    Liu, Bailian; Xiong, Ying; Deng, Hong; Gu, Shao; Jia, Fu; Li, Qunhui; Wang, Daxing; Gan, Xuewen; Liu, Wei

    2014-07-21

    The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p fractures (both p fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p knee, and ankle joint functional recovery between RSIN group and IIN group. RSIN may be a reliable and practical alternative method for the treatment of long bone fractures.

  19. Osteoporosis with vertebral fractures associated with pregnancy: two case reports

    OpenAIRE

    Raffaetà, Gloria; Mazzantini, Maurizio; Menconi, Agnese; Bottai, Vanna; Falossi, Francesca; Celauro, Ilenia; Guido, Giulio

    2014-01-01

    Pregnancy and lactation-associated osteoporosis (PAO) is a rare condition characterized by the occurrence of fragility fractures, most commonly vertebral, in late pregnancy or the early postpartum period. The prevalence, etiology and pathogenesis of this osteoporosis are unknown, although there are several hypotheses attempting to explain the etiopathogenesis of pregnancy associated osteoporosis. In this paper we present two cases of young women who developed severe PAO with vertebral fractur...

  20. Cephalomedullary fixation for femoral neck/intertrochanteric and ipsilateral shaft fractures: surgical tips and pitfalls

    Directory of Open Access Journals (Sweden)

    Bali Kamal

    2013-02-01

    Full Text Available 【Abstract】Objective: Surgical management op-tions for femoral shaft fracture and ipsilateral proximal fe-mur fracture vary from single-implant to double-implant fixation. Cephalomedullary fixation in such fractures has rela-tive advantages over other techniques especially because of less soft tissue dissection and immediate postoperative weight bearing with accelerated rehabilitation. However, the surgery is technically demanding and there is a paucity of literature describing the surgical techniques for this fixation. The aim of the study was to describe the surgical technique of cephalomedullary fixation for femoral shaft fracture and ipsilateral proximal femur fracture. Methods: Sixteen cases (10 males and 6 females with a mean age of 41.8 years of ipsilateral proximal femur and shaft fractures were treated by single-stage cephalomedullary fixa-tion at tertiary level trauma center in northern India. The fractures were classified according to AO classification. An intraoperative record of duration of surgery as well as tech-nical challenges unique to each fracture pattern was kept for all the patients. Results: The most common proximal femoral pattern was AO B2.1 observed in 9 of our patients. The AO B2.3 fractures were seen in 4 patients while the AO A1.2 fractures in 3 patients. Four of the AO B2.1 and 2 of the AO B2.3 frac-tures required open reduction with Watson-Jones approach. The mean operative time was around 78 minutes, which tended to decrease as the surgical experience increased. There was only one case of malreduction, which required revision surgery. Conclusion: Combination of ipsilateral femoral shaft fracture and neck/intertrochanteric fracture is a difficult frac-ture pattern for trauma surgeons. Cephalomedullary nail is an excellent implant for such fractures but it requires careful insertion to avoid complications. Surgery is technically de-manding with a definite learning curve. Nevertheless, a ma-jority of these

  1. Sport related stress fracture of the clavicle with non-union: Case report and review

    Science.gov (United States)

    Constantinou, Demitri; Kastanos, Konstantinos

    2008-01-01

    Stress fractures are relatively uncommon sports injuries and when they do occur, are mostly found in the lower limb. Stress fractures of the clavicle are particularly rare, having been described in a number of non-sport related pathologies, such as nervous tics and post radical neck dissection. In sport, there have only been seven cases reported in the literature. We report on a clavicle stress fracture in a 47-year-old male, partaking in recreational weight lifting activities. This is the first reported case of a non-union stress fracture of the clavicle. The patient underwent an open reduction and internal fixation and made a full recovery. PMID:21264151

  2. Avulsion Fracture of the Coracoid Process at the Coracoclavicular Ligament Insertion: A Report of Three Cases

    Directory of Open Access Journals (Sweden)

    Takeshi Morioka

    2016-01-01

    Full Text Available Avulsion fracture at the site of attachment of the coracoid process of the coracoclavicular ligament (CCL is extremely rare. We presented three adult cases of this unusual avulsion fracture associated with other injuries. Case  1 was a 25-year-old right-handed male with a left distal clavicular fracture with an avulsion fracture of the coracoid attachment of the CCL; this case was treated surgically and achieved an excellent outcome. Case  2 was a 39-year-old right-handed male with dislocation of the left acromioclavicular joint with two avulsion fractures: one at the posteromedial surface of the coracoid process at the attachment of the conoid ligament and one at the inferior surface of the clavicle at the attachment site of the trapezoid ligament; this case was treated conservatively, and unfavorable symptoms such as dull pain at rest and sharp pain during some daily activities remained. Case  3 was a 41-year-old right-handed female with a right distal clavicular fracture with an avulsion fracture of the coracoid attachment of the conoid ligament; this case was treated conservatively, and the distal clavicular fracture became typical nonunion. These three cases corresponded to type I fractures according to Ogawa’s classification as the firm scapuloclavicular connection was destroyed and also to double disruption of the superior shoulder suspensory complex. We recommend surgical intervention when treating patients with this type of acute or subacute injury, especially in those engaging in heavy lifting or overhead work.

  3. Simultaneous bilateral tibial tubercle avulsion fracture in a male teenager: case report and literature review.

    Science.gov (United States)

    Nicolini, Alexandre P; Carvalho, Rogerio T; Ferretti, Mario; Cohen, Moises

    2018-01-01

    Tibial tuberosity avulsion fractures are injuries accounting for less than 3% of all epiphyseal and 1% of all physeal injuries in adolescents. Bilateral injuries are very rare, with only 19 cases described in the literature. These types of fractures occur commonly in male teenagers during sport activities and are often associated with other orthopaedic disorders. We report the case of a male teenager with simultaneous bilateral tibial tubercle fractures, describe the evolution and treatment of this injury and review the literature on this subject. Case report.

  4. The isolated posterior malleolar fracture and syndesmotic instability : A case report and review of the literature

    NARCIS (Netherlands)

    Smeeing, Diederik P J; Houwert, Roderick M; Kruyt, Moyo C; Hietbrink, Falco

    2017-01-01

    INTRODUCTION: Ankle fractures are among the most common type of fractures in the lower extremity. A posterior malleolar fracture is frequently part of a more complex ankle fracture and only in rare cases it occurs as isolated injury. Posterior malleolar fractures often occur with associated

  5. Intrapartum sacral stress fracture due to pregnancy-related osteoporosis: a case report.

    Science.gov (United States)

    Oztürk, Gülcan; Külcü, Duygu Geler; Aydoğ, Ece

    2013-01-01

    Low back pain (LBP) and hip pain frequently occur during pregnancy and postpartum period. Although pelvic and mechanic lesions of the soft tissues are most responsible for the etiology, sacral fracture is also one of the rare causes. A 32-year-old primigravid patient presented with LBP and right hip pain which started 3 days after vaginal delivery. Although direct radiographic examination was normal, magnetic resonance imaging of the sacrum revealed sacral stress fracture. Lumbar spine and femoral bone mineral density showed osteoporosis as a risk factor. There were no other risk factors such as trauma, excessive weight gain, and strenuous physical activity. It is considered that the patient had sacral fatigue and insufficiency fracture in intrapartum period. The patient's symptoms subsided in 3 months after physical therapy and rest. In conclusion, sacral fractures during pregnancy and postpartum period, especially resulting from childbirth, are very rare. To date, there are two cases in the literature. In cases who even do not have risk factors related to vaginal delivery such as high birth weight infant and the use of forceps, exc., sacral fracture should be considered in the differential diagnosis of LBP and hip pain started soon after child birth. Pregnancy-related osteoporosis may lead to fracture during vaginal delivery.

  6. [Factors related to intraoperative retinal breaks in macular hole surgery].

    Science.gov (United States)

    Kumagai, K; Ogino, N; Demizu, S; Atsumi, K; Kurihara, H; Iwaki, M; Ishigooka, H; Tachi, N

    2001-02-01

    To evaluate the factors of intraoperative retinal breaks in macular hole surgery. This study included 558 eyes of 506 patients who underwent idiopathic macular hole surgery by one surgeon. Multiple regression was performed using the variables of gender, age, affected eye, lens status, stage, duration of symptoms, hole size, axial length, and lattice degeneration. The rate of retinal breaks was higher in stage 3 (16.0%) than in stage 4 (8.2%) (p = 0.014). In eyes with lattice degeneration intraoperative retinal breaks occurred in about 40% of the cases. Major factors were as follows: lattice degeneration (r = 0.24, p lattice degeneration, and gender (r = -0.18, p = 0.035) in eyes of stage 4 without lattice degeneration. The factors of intraoperative retinal breaks in macular hole surgery were lattice degeneration in all eyes and stage 3 in eyes without lattice degeneration. The high incidence of intraoperative retinal breaks in stage 3 was mainly due to the occurrence of posterior vitreous detachment. Male gender was a significant factor associated with intraoperative retinal breaks.

  7. Bilateral atypical insufficiency fractures of the proximal tibia and a unilateral distal femoral fracture associated with long-term intravenous bisphosphonate therapy: a case report

    Directory of Open Access Journals (Sweden)

    Imbuldeniya Arjuna

    2012-02-01

    Full Text Available Abstract Introduction Atypical insufficiency fractures of the femur in patients on long-term bisphosphonate therapy have been well described in recent literature. The majority of cases are associated with minimal or no trauma and occur in the subtrochanteric or diaphyseal region. Case presentation We describe the case of a 76-year-old British Caucasian woman who presented initially to an emergency department and then to her primary care physician with a long-standing history of bilateral knee pain after minor trauma. Plain radiographs showed subtle linear areas of sclerosis bilaterally in her proximal tibiae. Magnetic resonance imaging confirmed the presence of insufficiency fractures in these areas along with her left distal femur. There are very few reports of atypical insufficiency fractures involving the tibia in patients on long-term bisphosphonate therapy and this appears to be the only documented bilateral case involving the metaphyseal regions of the proximal tibia and distal femur. Conclusion In addition to existing literature describing atypical fractures in the proximal femur and femoral shaft, there is a need for increased awareness that these fractures can also occur in other weight-bearing areas of the skeleton. All clinicians involved in the care of patients taking long-term bisphosphonates need to be aware of the growing association between new onset lower limb pain and atypical insufficiency fractures.

  8. [Common types of massive intraoperative haemorrhage, treatment philosophy and operating skills in pelvic cancer surgery].

    Science.gov (United States)

    Wang, Gang-cheng; Han, Guang-sen; Ren, Ying-kun; Xu, Yong-chao; Zhang, Jian; Lu, Chao-min; Zhao, Yu-zhou; Li, Jian; Gu, Yan-hui

    2013-10-01

    To explore the common types of massive intraoperative bleeding, clinical characteristics, treatment philosophy and operating skills in pelvic cancer surgery. We treated massive intraoperative bleeding in 19 patients with pelvic cancer in our department from January 2003 to March 2012. Their clinical data were retrospectively analyzed. The clinical features of massive intraoperative bleeding were analyzed, the treatment experience and lessons were summed up, and the operating skills to manage this serious issue were analyzed. In this group of 19 patients, 7 cases were of presacral venous plexus bleeding, 5 cases of internal iliac vein bleeding, 6 cases of anterior sacral venous plexus and internal iliac vein bleeding, and one cases of internal and external iliac vein bleeding. Six cases of anterior sacral plexus bleeding and 4 cases of internal iliac vein bleeding were treated with suture ligation to stop the bleeding. Six cases of anterior sacral and internal iliac vein bleeding, one cases of anterior sacral vein bleeding, and one case of internal iliac vein bleeding were managed with transabdominal perineal incision or transabdominal cotton pad compression hemostasis. One case of internal and external iliac vein bleeding was treated with direct ligation of the external iliac vein and compression hemostasis of the internal iliac vein. Among the 19 patients, 18 cases had effective hemostasis. Their blood loss was 400-1500 ml, and they had a fair postoperative recovery. One patient died due to massive intraoperative bleeding of ca. 4500 ml. Most of the massive intraoperative bleeding during pelvic cancer surgery is from the presacral venous plexus and internal iliac vein. The operator should go along with the treatment philosophy to save the life of the patient above all, and to properly perform suture ligation or compression hemostasis according to the actual situation, and with mastered crucial operating hemostatic skills.

  9. MR findings in cases of suspected impacted fracture of the femoral neck

    International Nuclear Information System (INIS)

    Stiris, M.G.; Lilleaas, F.G.

    1997-01-01

    Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 patient who had sustained a nondisplaced acetabular fracture with increased joint fluid and muscle contusions. Three patients had muscle contusions only. Two patients had bone marrow contusions only, while 2 others with advanced coxarthrosis had increased joint fluid only. Three patients showed normal findings. Our findings led to emergency surgery in 13 cases, and conservative measures directed to the specific MR findings in 14 patients. Conclusion: MR imaging should be the first modality of choice in examining patients with a clinically suspected impacted fracture of the femoral neck where conventional films show negative or equivocal findings. (orig.)

  10. MR findings in cases of suspected impacted fracture of the femoral neck

    Energy Technology Data Exchange (ETDEWEB)

    Stiris, M.G.; Lilleaas, F.G. [Aker Hospital, Oslo (Norway). Dept. of Diagnostic Radiology

    1997-09-01

    Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 patient who had sustained a nondisplaced acetabular fracture with increased joint fluid and muscle contusions. Three patients had muscle contusions only. Two patients had bone marrow contusions only, while 2 others with advanced coxarthrosis had increased joint fluid only. Three patients showed normal findings. Our findings led to emergency surgery in 13 cases, and conservative measures directed to the specific MR findings in 14 patients. Conclusion: MR imaging should be the first modality of choice in examining patients with a clinically suspected impacted fracture of the femoral neck where conventional films show negative or equivocal findings. (orig.).

  11. An Impulse Control Disorder Case with Penile Fracture and Trichotillomania

    OpenAIRE

    CUMURCU, Birgül ELBOZAN

    2014-01-01

    Penile fractures are classically described as presenting with rapid detumescence of an erection associated with blunt trauma. This clinical finding is due to a tear in the tunica albuginea surrounding the corpora cavernosum. In this study, we report and discuss a case of trichotillomania and penile bending impulse resulting in penile fracture, which was operated in the urology clinic. The possible psychological and psychiatric problems underlying the impulsive behavior are discussed, and the ...

  12. Osteogenesis Imperfecta Diagnosed from Mandibular and Lower Limb Fractures: A Case Report.

    Science.gov (United States)

    Kobayashi, Yoshikazu; Satoh, Koji; Mizutani, Hideki

    2016-06-01

    Osteogenesis imperfecta (OI) is a congenital disease characterized by bone fragility and low bone mass. Despite the variety of its manifestation and severity, facial fractures occur very infrequently. Here, we report a case of an infant diagnosed with OI after mandibular and lower limb fractures. A boy aged 1 year and 3 months was brought to his neighboring hospital with a complaint of facial injury. He was transferred to our hospital to undergo operation 3 days later. Computed tomography images revealed multiple mandibular fractures including complete fracture in the symphysis and dislocated condylar fracture on the right side. Open reduction and internal fixation with absorbable implants was performed 7 days after injury. He fractured his right lower limb 2 months later. He was diagnosed with OI type IA by an orthopedist. He will be administered bone-modifying agents if he suffers from frequent fractures.

  13. Use of organic nitrates and the risk of hip fracture: a population-based case-control study.

    Science.gov (United States)

    Pouwels, Sander; Lalmohamed, Arief; van Staa, Tjeerd; Cooper, Cyrus; Souverein, Patrick; Leufkens, Hubertus G; Rejnmark, Lars; de Boer, Anthonius; Vestergaard, Peter; de Vries, Frank

    2010-04-01

    Use of organic nitrates has been associated with increased bone mineral density. Moreover, a large Danish case-control study reported a decreased fracture risk. However, the association with duration of nitrate use, dose frequency, and impact of discontinuation has not been extensively studied. Our objective was to evaluate the association between organic nitrates and hip fracture risk. A case-control study was conducted using the Dutch PHARMO Record Linkage System (1991-2002, n = 6,763 hip fracture cases and 26,341 controls). Cases had their first admission for hip fracture, whereas controls had not sustained any fracture after enrollment. Current users of organic nitrates were patients who had received a prescription within 90 d before the index date. The analyses were adjusted for disease and drug history. Current use of nitrates was not associated with a decreased risk of hip fracture [adjusted odds ratio (OR) = 0.93; 95% confidence interval (CI) = 0.83-1.04]. Those who used as-needed medication only had a lower risk of hip fracture (adjusted OR = 0.83; 95% CI = 0.63-1.08) compared with users of maintenance medication only (adjusted OR = 1.17; 95% CI = 0.97-1.40). No association was found between duration of nitrate use and fracture risk. Our overall analyses showed that risk of a hip fracture was significantly lower among users of as-needed organic nitrates, when compared with users of maintenance medication. Our analyses of hip fracture risks with duration of use did not further support a beneficial effect of organic nitrates on hip fracture, although residual confounding may have masked beneficial effects.

  14. Intraoperative Recurrent Laryngeal Nerve Monitoring in a Patient with Contralateral Vocal Fold Palsy

    Directory of Open Access Journals (Sweden)

    Bub-Se Na

    2017-10-01

    Full Text Available Recurrent laryngeal nerve injury can develop following cervical or thoracic surgery; however, few reports have described intraoperative recurrent laryngeal nerve monitoring. Consensus regarding the use of this technique during thoracic surgery is lacking. We used intraoperative recurrent laryngeal nerve monitoring in a patient with contralateral vocal cord paralysis who was scheduled for completion pneumonectomy. This case serves as an example of intraoperative recurrent laryngeal nerve monitoring during thoracic surgery and supports this indication for its use.

  15. [Intraoperative multidimensional visualization].

    Science.gov (United States)

    Sperling, J; Kauffels, A; Grade, M; Alves, F; Kühn, P; Ghadimi, B M

    2016-12-01

    Modern intraoperative techniques of visualization are increasingly being applied in general and visceral surgery. The combination of diverse techniques provides the possibility of multidimensional intraoperative visualization of specific anatomical structures. Thus, it is possible to differentiate between normal tissue and tumor tissue and therefore exactly define tumor margins. The aim of intraoperative visualization of tissue that is to be resected and tissue that should be spared is to lead to a rational balance between oncological and functional results. Moreover, these techniques help to analyze the physiology and integrity of tissues. Using these methods surgeons are able to analyze tissue perfusion and oxygenation. However, to date it is not clear to what extent these imaging techniques are relevant in the clinical routine. The present manuscript reviews the relevant modern visualization techniques focusing on intraoperative computed tomography and magnetic resonance imaging as well as augmented reality, fluorescence imaging and optoacoustic imaging.

  16. Upper extremity open fractures in hospitalized road traffic accident patients: adult versus pediatric cases.

    Science.gov (United States)

    Rubin, Guy; Peleg, Kobi; Givon, Adi; Rozen, Nimrod

    2017-10-24

    Fractures in pediatrics show epidemiological characteristics which are different from fractures in adults. The objective of this study was to examine the injury profiles of open upper extremity fractures (UEFs) in all modes of injury related to road traffic accidents (RTAs) in adult and pediatric hospitalized patients. Data on 103,465 RTA patients between 1997 and 2013 whose records were entered in a centralized country trauma database were reviewed. Data on open UEFs related to mode of injury (car, motorcycle, bicycle, and pedestrian) was compared between adult (18+ years) and pediatric (0-17 years) RTA patients. Of 103,465 RTA cases, 17,263 (16.7%) had UEFs. Of 73,087 adults, 13,237 (18.1%) included UEFs and of 30,378 pediatric cases, 4026 (13.2%) included UEFs (p open fractures. Adults had a greater risk for open fractures (2221, 13%) than the pediatric cases (522, 10.3%) (p open UEFs than the pediatric group (11 vs 8%, p = 0.0012). This study demonstrates the difference between adult and pediatric open fractures in hospitalized RTAs. We showed that adults had a greater risk for open UEFs compared to children, and the adult pedestrian group particularly had a significantly higher risk for open UEFs than the pediatric group.

  17. Plain film analysis of acetabular fracture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Soo; Han, Sang Suk; Yoon, Eu Giene; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan [Inje Medical College Paik Hospital, Pusan (Korea, Republic of)

    1986-02-15

    Acetabular fracture can result in severe limitation of the motion of the hip joint, which supports total weight of human body. Because of different methods of surgical approach according to fracture type, precise interpretation of X-ray films of acetabular fracture is required. We reviewed 38 cases of simple X-ray films showing acetabular fracture. The results were as follows: 1. Almost 60% of the cases-were in their 2nd and 3rd decades. 2. Twenty cases were male, and 18 cases were female. 3. The most common cause of the injury was traffic accident (33 cases, 86.8%), followed by fall down (4 cases, 10.5%), and slip down (1 case, 2.7%). 4. Elementary fractures were 21 cases (55.3%), and associated fractures were 17 cases (44.7%). 5. Among elementary fractures, posterior wall fractures were 9 cases (23.7%), followed by anterior column fractures (8 cases, 21.1%), anterior wall fractures (4 cases, 10.5%). 6. Among associated fractures, T-shaped fractures were 8 cases (21.1%), followed by both column fractures (6 cases, 15.8%), anterior and hemitransverse fractures (3 cases, 7.8%). 7. Other pelvic bone fractures associated with the acetabular fracture were as follows: fractures of contralateral pubic rami (6 cases, 15.8%) contralateral iliac bone (1 case, 2.6%) and ipsilateral iliac bone (1 case, 2.6%). 8. Injuries of other organs adjacent to the acetabulum were as follows: rupture of the bladder (3 cases, 7.9%), urethra (2 cases, 5.3%) and uterus (1 cases, 2.6%)

  18. Plain film analysis of acetabular fracture

    International Nuclear Information System (INIS)

    Kim, Chang Soo; Han, Sang Suk; Yoon, Eu Giene; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan

    1986-01-01

    Acetabular fracture can result in severe limitation of the motion of the hip joint, which supports total weight of human body. Because of different methods of surgical approach according to fracture type, precise interpretation of X-ray films of acetabular fracture is required. We reviewed 38 cases of simple X-ray films showing acetabular fracture. The results were as follows: 1. Almost 60% of the cases-were in their 2nd and 3rd decades. 2. Twenty cases were male, and 18 cases were female. 3. The most common cause of the injury was traffic accident (33 cases, 86.8%), followed by fall down (4 cases, 10.5%), and slip down (1 case, 2.7%). 4. Elementary fractures were 21 cases (55.3%), and associated fractures were 17 cases (44.7%). 5. Among elementary fractures, posterior wall fractures were 9 cases (23.7%), followed by anterior column fractures (8 cases, 21.1%), anterior wall fractures (4 cases, 10.5%). 6. Among associated fractures, T-shaped fractures were 8 cases (21.1%), followed by both column fractures (6 cases, 15.8%), anterior and hemitransverse fractures (3 cases, 7.8%). 7. Other pelvic bone fractures associated with the acetabular fracture were as follows: fractures of contralateral pubic rami (6 cases, 15.8%) contralateral iliac bone (1 case, 2.6%) and ipsilateral iliac bone (1 case, 2.6%). 8. Injuries of other organs adjacent to the acetabulum were as follows: rupture of the bladder (3 cases, 7.9%), urethra (2 cases, 5.3%) and uterus (1 cases, 2.6%).

  19. Elderly patient's mortality and morbidity following trochanteric fracture. A prospective study of 100 cases.

    Science.gov (United States)

    Mnif, H; Koubaa, M; Zrig, M; Trabelsi, R; Abid, A

    2009-11-01

    Trochanteric fractures are a major source of mortality, morbidity and functional impairment in the elderly. Morbidity is closely related to the degree of instability and comminution and is substantially influenced by the quality of reduction and internal fixation. Advanced age and associated co-morbidities are two decisive factors of mortality secondary to trochanteric fracture. This prospective study examined the epidemiological profile of trochanteric fractures and assessed mortality and morbidity with the aim of establishing management guidelines and improving prevention strategies. One hundred patients were included; 60% were male. Mean age was 76 years (range, 60-96 yrs). One, or more than one, co-morbidities were present in 68% of cases. The fractures were caused by a simple fall in 90% of cases. Fractures were classified according to the criteria of Ramadier and the ones of Ender. Sixty-five percent of these fractures were unstable. A dynamic hip screw was systematically used as the standard means of internal fixation. Anatomic and functional results were analyzed in 82 patients (18 had died within the first year following fracture occurrence). Mean follow-up period was 24 months (range, 12-36 months). Bone healing was achieved in 96% of cases. There were numerous postoperative complications (four cases of thromboembolism, fourteen immobility-related complications, two infections, six secondary displacement combined to loss of fixation, four non-unions, and nine malunions). At 2 years follow-up, 28 patients had died. Mortality was strongly correlated with older age (over 90 years), associated co-morbidity and fracture instability. Good functional outcomes (72%) correlated with younger age (60-74 years), fracture stability, adequate reduction and internal fixation. In stable trochanteric fractures, osteosynthesis by dynamic screw-plate is more effective than alternative techniques (blade-plate, nail-plate, Ender nail or even trochanteric nail). In unstable

  20. The value of intraoperative sonography in low grade glioma surgery.

    Science.gov (United States)

    Petridis, Athanasios K; Anokhin, Maxim; Vavruska, Jan; Mahvash, Mehran; Scholz, Martin

    2015-04-01

    There is a number of different methods to localize a glioma intraoperatively. Neuronavigation, intraoperative MRI, 5-aminolevulinic acid, as well as intraoperative sonography. Every method has its advantages and disadvantages. Low grade gliomas do not show a specific signal with 5-aminolevulinic acid and are difficult to distinguish macroscopically from normal tissue. In the present study we stress out the importance of intraoperative diagnostic ultrasound for localization of low grade gliomas. We retrospectively evaluated the charts and MRIs of 34 patients with low grade gliomas operated in our department from 2011 until December 2014. The efficacy of ultrasound as an intraoperative navigational tool was assessed. In 15 patients ultrasound was used and in 19 not. Only histologically proven low grades gliomas (astrocytomas grade II) were evaluated. In none of the patients where ultrasound (combined with neuronavigation) was used (N=15) to find the tumors, the target was missed, whereas the exclusive use of neuronavigation missed the target in 5 of 19 cases of small subcortical low grade gliomas. Intraoperative ultrasound is an excellent tool in localizing low grade gliomas intraoperatively. It is an inexpensive, real time neuronavigational tool, which overcomes brain shift. Even when identifying the tumors with ultrasound is very reliable, the extend of resection and the decision to remove any residual tumor with the help of ultrasound is at the moment unreliable. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Nutritional risk assessment for Hip fracture, A Case control study

    OpenAIRE

    Torbergsen, Anne Cathrine

    2016-01-01

    The study was conducted at Oslo University Hospital, Norway. Patients were included from September 2009 until April 2011. In total 116 patients and 73 healthy non-fractured controls participated. The study has 3 parts. In the first part, we studied micronutrients and the risk of hip fracture in a case control study. In the second part, we conducted a randomized controlled nutrition intervention trial and finally, in the third part, we studied if micronutrients were associated with delirium in...

  2. BISPHOSPHONATE INDUCED STRESS FRACTURE OF BILATERAL FEMUR: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Saidapur

    2015-08-01

    Full Text Available Osteoporosis is a common problem affecting people after 4 - 5 decade of life. There are various treatment options available for Osteoporosis and Bisphosphonates are widely used. Bisphosphonates work by blocking osteoclast mediated bone resorption and can be given in oral and injectable forms. R ecent studies have brought to light the risk of sub trochanteric stress fracture secondary to bisphosphonate therapy. Here we are presenting a case with bilateral sub trochanteric fracture following prolonged bisphosphonate therapy

  3. A case of pathological rib fractures: focal osteolysis or osteoporosis?

    Science.gov (United States)

    Vrbanić, T S L; Novak, S; Sestan, B; Tudor, A; Gulan, G

    2008-03-01

    This paper reports on a unique, previously unreported, successful outcome in the case of a patient with focal osteolytic lesions of the ribs as a first sign of osteoporosis. The lesions were detected by chance after acute cough-induced rib fractures were seen on plain chest radiographs. The diagnosis had to be approached as a diagnosis of exclusion since known causes of the osteolytic process had to be eliminated. The authors describe multiple focal osteolytic lesions with rib fractures appearing in a pattern that could be confused with metastases. Laboratory results were normal. Final diagnosis was based on plain radiography, bone scan and bone densitometry. Pharmacomedical treatments for osteoporosis were applied. The patient was observed between the year 2000 and 2005. Five years later radiological and bone scintigraphy revealed resolution of the lesion. We conclude that osteoporosis should be included in the differential diagnosis of asymptomatic focal osteolysis of the ribs with rib fractures as a complication of acute cough. The case suggests that focal osteolytic lesions of the ribs may regress over time and become scintigraphically inactive.

  4. Maxillary distraction osteogenesis using Le Fort I osteotomy without intraoperative down-fracture.

    Science.gov (United States)

    Yamauchi, K; Mitsugi, M; Takahashi, T

    2006-06-01

    The aim of this study is to present a technique for maxillary distraction osteogenesis using Le Fort I osteotomy without down-fracture. Six cleft-related patients suffering from severe midfacial deficiency were treated with maxillary distraction osteogenesis. The RED II system was chosen as the extraoral device and the Leipzig retention plate system to anchor the maxillary segment. Maxillary distraction osteogenesis was successful in all cases. Cephalometric and clinical evaluation after an average follow-up period of 1 year showed stable results with respect to skeletal and dental relationships. The SNA angle increased from 72.3 degrees to 81.4 degrees and the ANB angle increased by 11.0 degrees immediately after removing the distraction device. After 1 year, the sagittal bone gain remained and the SNA angle had decreased by 0.8 degrees . This technique seems to minimize the risk of the surgical procedure and shorten the operation time. It may become an alternative method for the treatment of patients with severe midfacial hypoplasia.

  5. Ipsilateral Fracture Shaft Femur with Neglected Dislocation of Prosthesis: A Case Report

    Directory of Open Access Journals (Sweden)

    Mantu Jain

    2013-10-01

    Full Text Available Introduction: Neglected hip dislocation is rare in today’s world and after prosthesis replacement even rarer finding. However such patients may not report to surgeons until they develop secondary complications. Management of such patient’s is a challenge to the treating surgeon and need to be tailored suiting to patient’s demands, expectations and constraints of financial resources. We did not find a similar case in the electronic and print media and therefore report this case which was innovatively managed. Case Report: A 60 year farmer presented with fracture shaft femur and ipsilateral dislocation prosthesis of right hip. He had a hemiarthroplasty done for fracture neck of femur in the past but used to walk with a lurch since he started to ambulate after discharge. However he was satisfied despite “some problems” which had caused shortening of his limb. The patient was informed of the various treatment options and their possible complications. He expressed his inability to afford a Total Hip Arthroplasty (THA at any stage and consented for other options discussed with him. The patient was positioned supine and adductor tenotomy done. Next he was positioned laterally and the fracture was fixed with heavy duty broad dynamic compression plate and screws. The wound was temporarily closed. Now through the previous scar via posterior approach the hip was exposed. The prosthesis was found to be firmly fixed to the proximal femur. The acetabulum was cleared with fibrous tissue. All attempts the prosthesis to relocate the prosthesis failed after several attempts and it was best decided to leave alone. Post operatively period was uneventful. At follow up he refused for any further manoeuvre in future inform of heavy traction and attempts to reduce the same. At one year when he was walking unaided and his X-rays showed that fracture had well united his SF-36 score was PCS – 49.6 and MCS – 51.9. Conclusion: Ipsilateral shaft femur fracture

  6. Skin puckering an uncommon sign of underlying humeral neck fracture: a case report.

    LENUS (Irish Health Repository)

    Davarinos, N

    2012-01-31

    Skin puckering is a sign that is well associated with certain fractures such as supracondylar humeral fractures in children. To our knowledge, there has been only one clinical report of skin puckering associated with fractured neck of humerus of an adult. This is a second such case of fractured proximal humerus in an adult presenting with skin puckering and the first from the Republic of Ireland. Skin puckering is suggestive of soft tissue interposition and may be an important clinical sign indicating the need for internal fixation.

  7. Manubrial stress fractures diagnosed on MRI: report of two cases and review of the literature.

    Science.gov (United States)

    Baker, Jonathan C; Demertzis, Jennifer L

    2016-06-01

    In contrast to widely-reported sternal insufficiency fractures, stress fractures of the sternum from overuse are extremely rare. Of the 5 cases of sternal stress fracture published in the English-language medical literature, 3 were in the sternal body and only 2 were in the manubrium. We describe two cases of manubrial stress fracture related to golf and weightlifting, and present the first report of the MR findings of this injury. In each of these cases, the onset of pain was atraumatic, insidious, and associated with increased frequency of athletic activity. Imaging was obtained because of clinical diagnostic uncertainty. On MRI, each patient had a sagittally oriented stress fracture of the lateral manubrium adjacent to the first rib synchondrosis. Both patients had resolution of pain after a period of rest, with subsequent successful return to their respective activities. One patient had a follow-up MRI, which showed resolution of the manubrial marrow edema and fracture line. Based on the sternal anatomy and MR findings, we hypothesize that this rare injury might be caused by repetitive torque of the muscle forces on the first costal cartilage and manubrium, and propose that MRI might be an effective means of diagnosing manubrial stress fracture.

  8. Manubrial stress fractures diagnosed on MRI: report of two cases and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Jonathan C.; Demertzis, Jennifer L. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, Musculoskeletal Section, St Louis, MO (United States)

    2016-06-15

    In contrast to widely-reported sternal insufficiency fractures, stress fractures of the sternum from overuse are extremely rare. Of the 5 cases of sternal stress fracture published in the English-language medical literature, 3 were in the sternal body and only 2 were in the manubrium. We describe two cases of manubrial stress fracture related to golf and weightlifting, and present the first report of the MR findings of this injury. In each of these cases, the onset of pain was atraumatic, insidious, and associated with increased frequency of athletic activity. Imaging was obtained because of clinical diagnostic uncertainty. On MRI, each patient had a sagittally oriented stress fracture of the lateral manubrium adjacent to the first rib synchondrosis. Both patients had resolution of pain after a period of rest, with subsequent successful return to their respective activities. One patient had a follow-up MRI, which showed resolution of the manubrial marrow edema and fracture line. Based on the sternal anatomy and MR findings, we hypothesize that this rare injury might be caused by repetitive torque of the muscle forces on the first costal cartilage and manubrium, and propose that MRI might be an effective means of diagnosing manubrial stress fracture. (orig.)

  9. Manubrial stress fractures diagnosed on MRI: report of two cases and review of the literature

    International Nuclear Information System (INIS)

    Baker, Jonathan C.; Demertzis, Jennifer L.

    2016-01-01

    In contrast to widely-reported sternal insufficiency fractures, stress fractures of the sternum from overuse are extremely rare. Of the 5 cases of sternal stress fracture published in the English-language medical literature, 3 were in the sternal body and only 2 were in the manubrium. We describe two cases of manubrial stress fracture related to golf and weightlifting, and present the first report of the MR findings of this injury. In each of these cases, the onset of pain was atraumatic, insidious, and associated with increased frequency of athletic activity. Imaging was obtained because of clinical diagnostic uncertainty. On MRI, each patient had a sagittally oriented stress fracture of the lateral manubrium adjacent to the first rib synchondrosis. Both patients had resolution of pain after a period of rest, with subsequent successful return to their respective activities. One patient had a follow-up MRI, which showed resolution of the manubrial marrow edema and fracture line. Based on the sternal anatomy and MR findings, we hypothesize that this rare injury might be caused by repetitive torque of the muscle forces on the first costal cartilage and manubrium, and propose that MRI might be an effective means of diagnosing manubrial stress fracture. (orig.)

  10. Non traumatic fractures of the lumbar spine and seizures: case report

    Directory of Open Access Journals (Sweden)

    Moscote-Salazar Luis Rafael

    2015-12-01

    Full Text Available Injury-induced seizures may appear clinically asymptomatic and can be easily monitored by the absence of trauma and post-ictal impairment of consciousness. Patients with epilepsy have a higher risk of compression fractures, leading to serious musculoskeletal injuries, this type of non-traumatic compression fractures of the spine secondary to seizures are rare lesions, and is produced by the severe contraction of the paraspinal muscles that can achieve the thoracic spine fracture. Seizures induced lesions may appear clinically asymptomatic and can be easily monitored by the absence of trauma and post-ictal impairment of consciousness. We present a case report.

  11. Surgery for traumatic facial nerve paralysis: does intraoperative monitoring have a role?

    Science.gov (United States)

    Ashram, Yasmine A; Badr-El-Dine, Mohamed M K

    2014-09-01

    The use of intraoperative facial nerve (FN) monitoring during surgical decompression of the FN is underscored because surgery is indicated when the FN shows more than 90 % axonal degeneration. The present study proposes including intraoperative monitoring to facilitate decision taking and provide prognostication with more accuracy. This prospective study was conducted on ten patients presenting with complete FN paralysis due to temporal bone fracture. They were referred after variable time intervals for FN exploration and decompression. Intraoperative supramaximal electric stimulation (2-3 mA) of the FN was attempted in all patients both proximal and distal to the site of injury. Postoperative FN function was assessed using House-Brackmann (HB) scale. All patients had follow-up period ranging from 7 to 42 months. Three different patterns of neurophysiological responses were characterized. Responses were recorded proximal and distal to the lesion in five patients (pattern 1); only distal to the lesion in two patients (pattern 2); and neither proximal nor distal to the lesion in three patients (pattern 3). Sporadic, mechanically elicited EMG activity was recorded in eight out of ten patients. Patients with pattern 1 had favorable prognosis with postoperative function ranging between grade I and III. Pattern 3 patients showing no mechanically elicited activity had poor prognosis. Intraoperative monitoring affects decision taking during surgery for traumatic FN paralysis and provides prognostication with sufficient accuracy. The detection of mechanically elicited EMG activity is an additional sign predicting favorable outcome. However, absence of responses did not alter surgeon decision when the nerve was found evidently intact.

  12. Outcomes of macular hole surgery in patients treated intraoperatively for retinal breaks and/or lattice degeneration.

    Science.gov (United States)

    Hwang, John; Escariao, Paulo; Iranmanesh, Reza; Tosi, Gian Marco; Chang, Stanley

    2007-01-01

    To assess the outcome of macular hole surgery in patients treated intraoperatively for retinal breaks and/or lattice degeneration. Retrospective review of patients who underwent macular hole surgery from September 1998 to August 2005. Outcomes in eyes that received intraoperative endolaser photocoagulation for retinal breaks and/or lattice degeneration were compared to outcomes in a case-matched control group without retinal breaks or lattice degeneration. A total of 235 consecutive macular hole surgery cases were reviewed. Twenty-four eyes from 24 patients received intraoperative endolaser photocoagulation for retinal breaks and/or lattice degeneration. Macular hole closure occurred in all case and control eyes without any incidence of postoperative retinal detachment. Best-corrected visual acuity improvement of at least three Snellen lines occurred in 100% of case eyes and 92% of control eyes. Outcomes of macular hole surgery in patients with retinal breaks and/or lattice degeneration are similar to outcomes in the overall population when these conditions are treated with intraoperative endolaser photocoagulation. Postoperative retinal detachment does not appear to be correlated with treated retinal tears and greater attention should focus on detecting and managing intraoperative breaks. In our hands, routine use panoramic viewing has replaced indirect ophthalmoscopy, by saving time, and reducing the risk of contamination.

  13. Minimally invasive plating osteosynthesis for mid-distal third humeral shaft fractures.

    Science.gov (United States)

    Lian, Kejian; Wang, Lei; Lin, Dasheng; Chen, Zhiwen

    2013-08-01

    Mid-distal third humeral shaft fractures can be effectively treated with minimally invasive plating osteosynthesis and intramedullary nailing (IMN). However, these 2 treatments have not been adequately compared. Forty-seven patients (47 fractures) with mid-distal third humeral shaft fractures were randomly allocated to undergo either minimally invasive plating osteosynthesis (n=24) or IMN (n=23). The 2 groups were similar in terms of fracture patterns, fracture location, age, and associated injuries. Intraoperative measurements included blood loss and operative time. Clinical outcome measurements included fracture healing, radial nerve recovery, and elbow and shoulder discomfort. Radiographic measurements included fracture alignment, time to healing, delayed union, and nonunion. Functional outcome was satisfactory in both groups. Mean American Shoulder and Elbow Surgeons score and Mayo score were both better for the minimally invasive plating osteosynthesis group than for the IMN group (98.2 vs 97.6, respectively, and 93.5 vs 94.1, respectively; Pshaft fractures. Minimally invasive plating osteosynthesis is more suitable for complex fractures, especially for radial protection and motion recovery of adjacent joints, compared with IMN for simple fractures. Copyright 2013, SLACK Incorporated.

  14. Perioperative lateral trochanteric wall fractures: sliding hip screw versus percutaneous compression plate for intertrochanteric hip fractures.

    Science.gov (United States)

    Langford, Joshua; Pillai, Gita; Ugliailoro, Anthony D; Yang, Edward

    2011-04-01

    This study was performed to determine the incidence of perioperative lateral wall fractures with a standard sliding hip screw (SHS) versus a percutaneous compression plate (PCCP) using identical meticulous closed reduction techniques in both groups. Retrospective analysis of a prospective trauma registry. Urban Level I trauma center. Over a 7-year period, 337 patients with intertrochanteric hip fractures were treated with either a SHS or a PCCP at our institution. The PCCP group (Group 1) consisted of 200 patients, of which 141 (71%) had adequate images to be included in the study. The SHS group (Group 2) consisted of 137 patients, of which 100 (73%) had adequate images to be included in the study. Closed reduction and plate application with either a standard sliding hip screw or a percutaneous compression plate for an Orthopaedic Trauma Association 31A1 or 31A2 intertrochanteric hip fracture. : Radiographic evidence of lateral trochanteric wall fracture as measured by intraoperative and perioperative radiographs. There was an overall lateral wall fracture incidence of 20% in the SHS group versus 1.4% in the PCCP group (P fracture types, there was a lateral wall fracture incidence of 29.8% in the SHS group versus 1.9% in the PCCP group (P trochanteric wall fracture compared with the SHS group. This difference became greater when just unstable intertrochanteric fractures were analyzed. An anatomic reduction, combined with a device (PCCP) that uses small-diameter defects in the lateral trochanteric wall, essentially eliminates perioperative lateral trochanteric wall fractures.

  15. Update on open reduction and internal fixation of unstable pelvic fractures during pregnancy: case reports

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    Full Text Available ABSTRACT This article aims to report four cases of unstable pelvic fractures in pregnant women treated by open reduction and internal fixation. Cases report: The study included four cases of pregnant women with unstable pelvic fractures; their outcomes were analyzed and discussed. Data were obtained from two University Hospitals. The mean age of women was 23 years; most (3/4 were primiparous, with a mean pregnancy age of 23 weeks. Two women had Malgaigne-type fractures and the other two had symphyseal disjunction associated with acetabular fractures. All fractures were treated surgically. One foetus was dead on admission to hospital. The other three developed well, along with their mothers. Good evolution was only possible with careful pre-, peri-, and postoperative care for the mother, as well as foetal assessment by a multidisciplinary team. In complex cases such as those presented in the present study, pre-, peri-, and postoperative care are mandatory, as well as the presence of a multidisciplinary team. The mother's life always takes priority in acute clinical pictures, as it offers the best chance of survival to both mother and child.

  16. Radial forearm free flap morbidity: A rare case of a normal preoperative arteriogram and acute intraoperative hand ischemia

    OpenAIRE

    Bruner, Terrence W; Hanasono, Matthew M; Skoracki, Roman J

    2011-01-01

    The radial forearm free flap is ideal for reconstructive microsurgery due to its thin, pliable fasciocutaneous tissue, reliable anatomy and ease and simplicity of flap elevation. However, one of the major complications is hand ischemia due to sacrifice of the radial artery, although it is a rare occurrence. A case involving a 73-year-old man who developed intraoperative hand ischemia after elevation of a radial forearm free flap is presented.

  17. Intraoperative ultrasonography of liver, bile ducts and pancreas

    Directory of Open Access Journals (Sweden)

    Luciana Mendes de Oliveira Cerri

    Full Text Available The use of intraoperative ultrasonography (IOUS to evaluate liver, bile ducts and pancreatic disease, as compared to the results of preoperative ultrasonography and CT, is discussed. Forty-two patients who underwent abdominal surgery for suspected hepatobiliary and/or pancreatic disease were studied. The intraoperative study was carried out with a portable apparatus (Aloka 500, Japan, using 5.0 MHz and 7.5 MHz linear sterile transducers. The main indications for IOUS were the search for and/or evaluation of primary hepatic masses,hepatic abscesses or metastases, obstructive jaundice, or neuroendocrine tumors. In 15 cases (38.5 percent from the hepatobiliary group and in 7 cases (58.3 percent from the pancreatic group, a difference between preoperative and intraoperative findings was observed. The main difference was observed in relation to the number and size of hepatic and pancreatic lesions. The relationship between the lesions and the vascular structures was evaluated through IOUS. The method was also used to guide surgical procedures such as biopsies, the alcoholization of nodules, and the drainage of abscesses. IOUS plays an important role in detecting small hepatic and pancreatic nodules, in the assessment of anatomical relationships between the lesions and the vascular structures, and in the performance of interventionist procedures.

  18. Renal artery stent fracture with refractory hypertension: a case report and review of the literature.

    Science.gov (United States)

    Chua, Su-Kiat; Hung, Huei-Fong

    2009-07-01

    A 73-year-old man with resistant hypertension and impaired renal function underwent stenting for right renal artery (RRA) stenosis. Two years later, he presented with uncontrolled hypertension and worse renal function. Renal arteriogram revealed RRA stent fracture with in-stent restenosis. Another stent was deployed. Four months later, however, renal arteriogram revealed in-stent restenosis again. This time, balloon angioplasty alone was performed. He had been symptom-free with stable condition at 2-year follow-up. A literature review disclosed six renal artery stent fracture cases, including the present one, who developed in-stent stenosis resulted from stent fracture. Two major anatomy features of renal artery stenosis were suggestive for development of stent fracture: (1) renal artery entrapment by diaphragmatic crus, and (2) mobile kidney with acute angulation at proximal segment of the renal artery. It is important to detect this etiology of renal artery stenosis because stenting in these vessels may contribute to in-stent restenosis or stent fracture. Management of renal artery stent fracture, including endovascular treatment or aortorenal bypass, should be considered on a case-by-case basis in relation to clinical settings. Copyright 2009 Wiley-Liss, Inc.

  19. Stress fractures of the ribs in elite competitive rowers: a report of nine cases

    Energy Technology Data Exchange (ETDEWEB)

    Dragoni, S. [Institute of Sport Medicine and Science of the Italian Olympic Committee, Department of Radiology, Rome (Italy); Giombini, A.; Ripani, M. [University of Motor Sciences, Department of Health, Rome (Italy); Di Cesare, A. [University of Rome ' ' La Sapienza' ' , Department of Physical Medicine and Rehabilitation, Rome (Italy); Magliani, G. [Medical Department of the Italian State Police, Rome (Italy)

    2007-10-15

    The objective was to report the clinical and imaging patterns of nine cases of stress fractures of the rib diagnosed in Italian Olympic rowers. Nine patients with stress fractures of the rib detected from 103 (8.7%) Italian team rowers competing between May 2000 and May 2006 were identified based on the database of a sports medicine institute. All athletes were male. They were aged between 17 and 31 years (mean: 24.4). Patient weight, fracture location, rowing side and imaging methods employed were noted. The diagnosis was made based on history, clinical examination and Tc-99m MDP bone scintigraphy. Eight of the 9 fractures were located anterolaterally between the fourth and ninth rib. In 1 of the 5 athletes with standard radiographs, a fracture line was visible and in 4 there was callus formation. In 2 athletes sonography was performed, which detected discontinuity of the rib surface and callus formation (1 case each). Stress fractures of the ribs are relatively common in competitive rowers. They are characterized by increasing lateral chest pain and typical scintigraphic, radiographic and sonographic findings. (orig.)

  20. Stress fractures of the ribs in elite competitive rowers: a report of nine cases

    International Nuclear Information System (INIS)

    Dragoni, S.; Giombini, A.; Ripani, M.; Di Cesare, A.; Magliani, G.

    2007-01-01

    The objective was to report the clinical and imaging patterns of nine cases of stress fractures of the rib diagnosed in Italian Olympic rowers. Nine patients with stress fractures of the rib detected from 103 (8.7%) Italian team rowers competing between May 2000 and May 2006 were identified based on the database of a sports medicine institute. All athletes were male. They were aged between 17 and 31 years (mean: 24.4). Patient weight, fracture location, rowing side and imaging methods employed were noted. The diagnosis was made based on history, clinical examination and Tc-99m MDP bone scintigraphy. Eight of the 9 fractures were located anterolaterally between the fourth and ninth rib. In 1 of the 5 athletes with standard radiographs, a fracture line was visible and in 4 there was callus formation. In 2 athletes sonography was performed, which detected discontinuity of the rib surface and callus formation (1 case each). Stress fractures of the ribs are relatively common in competitive rowers. They are characterized by increasing lateral chest pain and typical scintigraphic, radiographic and sonographic findings. (orig.)

  1. No evidence of depression, anxiety, and sexual dysfunction following penile fracture.

    Science.gov (United States)

    Penbegul, N; Bez, Y; Atar, M; Bozkurt, Y; Sancaktutar, A A; Soylemez, H; Ozen, S

    2012-01-01

    There is a gap in the literature about psychological status of patients following penile fracture surgery. We aimed to assess the long-term psychological status of penile fracture patients who have been treated by immediate surgical repair. A total of 32 patients with penile fracture have been treated surgically at our center. These 32 patients and 30 healthy control subjects were included in the study. All participants have completed the Hospital Anxiety and Depression Scale (HADS), Glombok-Rust Inventory of Satisfaction Scale (GRISS), and the premature ejaculation diagnostic tool (PEDT). The mean age of patients was 30.4 years and the mean body mass index was 27.3 kg m(-2). Sexual intercourse was the most common cause of the fracture. Immediate surgical repair was performed in all cases using a circumferential subcoronal incision and none of the patients had urethral injury intraoperatively. All tears were unilateral with a mean size of 1.5 cm. Only two patients had superficial dorsal vein rupture. At the day of assessment, the mean time elapsed after penile trauma was 15.9±6.3 months (range: 6-23). Only three patients had complications due to penile fracture including minimal penile curvature, penile nodule, and penile pain during intercourse. The mean scores obtained from PEDT, HADS, and GRISS did not show any statistically significant difference between groups. Anxiety, depression, premature ejaculation, and sexual dyssatisfaction levels were similar in both penile fracture patients who underwent immediate surgical repair and healthy control subjects. Immediate surgical repair of corporal ruptures have not shown any harmful psychogenic sequelae on patients with penile fracture.

  2. The lymphoscintigraphy and intraoperative gamma detection of sentinel lymph node in oral cavity carcinoma

    International Nuclear Information System (INIS)

    Zhao Xinming; Zhang Jingmian; Wang Jianfang; Li Dezhi; Sun Li; Dai Chunnuan; He Yang

    2006-01-01

    Objective: To evaluate the role of lymphoscintigraphy and intraoperative gamma probe detection of sentinel lymph node (SLN) in oral cavity carcinoma. Methods: 99 Tc m labeled dextran (DX) was injected submucously at the center of oral cavity carcinoma before operation. The SLN identified by lymphoscintigraphy and intraoperative gamma counter probe were dissected out from the exited tissue. All sentinel and other lymph nodes were sent for pathological examination. Results: In all 33 cases, SLN and other lymph nodes were clear identified by lymphoscintigraphy. Forty-three SLNs were seen, among them 1 in 25 cases, 2 in 6 cases and 3 in 2 cases. Metastases were detected by biopsy in SLN in 9 cases, however, 11 cases showed positive neck lymph node metastases. The sensitivity of SLN gamma detection was 100% and in biopsy sensitivity was 81.82%, accuracy was 93.94%, false positive rate was 0, and false negative rate was 18.18%. Conclusions: Intraoperative gamma probe detection is the reliable approach to identify SLN in oral cavity carcinoma. Lymphoscintigraphy is the base of localization for oral cavity carcinoma. (authors)

  3. A paediatric case of bilateral mandibular condyle fracture presenting with bloody otorrhoea following trauma.

    Science.gov (United States)

    Chan, Yat Chun; Au-Yeung, Kwan Leong

    2017-04-22

    A 7-year-old boy presented to the emergency department with bilateral bloody otorrhoea after falling from his scooter. Skull base fracture was suspected. CT showed no evidence of skull base fracture but bilateral mandibular condyle and external acoustic canals fractures. We report this case to illustrate a rare possibility of bilateral external acoustic canal fracture associated with condylar fracture in trauma patients presented with bloody otorrhoea. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. Fracture of the acetabulum with femoral artery injury presenting late: A case report

    Directory of Open Access Journals (Sweden)

    Sivaprasad Kalyanasundaram

    2016-02-01

    Full Text Available This study reports a rare case of both column acetabulum fracture with femoral artery injury that presented late and was managed with arterial reconstruction and fracture fixation.A thirty-one year old man sustained both column acetabular fracture on the left in a motor vehicle accident. On admission there was no obvious neuro-vascular deficit. During surgery for the fracture after 7 days of the injury the femoral artery was found to be severely crushed with no blood flow. The anterior column of the acetabulum was stabilised followed by resection and reconstruction of the femoral artery. The post-operative period was uneventful and he was discharged normally. At 6 months from injury the fractures had united well with excellent limb circulation and good lower limb function.Femoral artery injury with acetabular fracture is rare and late presentations are unreported hitherto. The results of fracture stabilisation and vessel reconstruction seem to be excellent. Literature of similar injuries is reviewed. Keywords: Acetabular fractures, Both column fractures, Anterior column fractures, Vascular injury, Femoral artery injury

  5. Diagnostic Ultrasonography of an Ankle Fracture Undetectable by Conventional Radiography: A Case Report

    Science.gov (United States)

    Daniels, Clinton J.; Welk, Aaron B.; Enix, Dennis E.

    2016-01-01

    Objective The purpose of this study is to present diagnostic ultrasonography assessment of an occult fracture in a case of persistent lateral ankle pain. Clinical Features A 35-year-old woman presented to a chiropractic clinic with bruising, swelling, and pain along the distal fibula 3 days following an inversion ankle trauma. Prior radiographic examination at an urgent care facility was negative for fracture. Conservative care over the next week noted improvement in objective findings, but the pain persisted. Intervention and Outcome Diagnostic ultrasonography was ordered to assess her persistent ankle pain and showed a minimally displaced fracture of the fibula 4 cm proximal to the lateral malleolus. The patient was referred to her primary care physician and successfully managed with conservative care. Conclusion In this case, diagnostic ultrasonography was able to identify a Danis-Weber subtype B1 fracture that was missed by plain film radiography. PMID:27069430

  6. Pathological (late) fractures of the mandibular angle after lower third molar removal: a case series.

    Science.gov (United States)

    Cutilli, Tommaso; Bourelaki, Theodora; Scarsella, Secondo; Fabio, Desiderio Di; Pontecorvi, Emanuele; Cargini, Pasqualino; Junquera, Luis

    2013-04-30

    Pathological (late) fracture of the mandibular angle after third molar surgery is very rare (0.005% of third molar removals). There are 94 cases reported in the literature; cases associated with osseous pathologies such as osteomyelitis or any local and systemic diseases that may compromise mandibular bone strength have not been included. We describe three new cases of pathological (late) fracture of the mandibular angle after third molar surgery. The first patient was a 27-year-old Caucasian man who had undergone surgical removal of a 3.8, mesioangular variety, class II-C third molar 20 days before admission to our clinic. The fracture of his left mandibular angle, complete and composed, occurred during chewing. The second patient was a 32-year-old Caucasian man. He had undergone surgical removal of a 3.8, mesioangular variety, class II-B third molar 22 days before his admission. The fracture, which occurred during mastication, was studied by computed tomography that showed reparative tissue in the fracture site. The third patient was a 36-year-old Caucasian man who had undergone surgical removal of a 3.8, vertical variety, class II-C third molar 25 days before the observation. In this case the fracture of his mandibular angle was oblique (unfavorable), complete and composed. The fracture had occurred during chewing. We studied the fracture by optical projection tomography and computed tomography.All of the surgical removals of the 3.8 third molars, performed by the patients' dentists who had more than 10 years of experience, were difficult. We treated the fractures with open surgical reduction, internal fixation by titanium miniplates and intermaxillary elastic fixation removed after 6 weeks. The literature indicates that the risk of pathological (late) fracture of the mandibular angle after third molar surgery for total inclusions (class II-III, type C) is twice that of partial inclusions due to the necessity of ostectomies more generous than those for partial

  7. Pilot case-control investigation of risk factors for hip fractures in the urban Indian population

    Directory of Open Access Journals (Sweden)

    Malhotra Nidhi

    2010-03-01

    Full Text Available Abstract Background Despite the reported high prevalence of osteoporosis in India, there have been no previous studies examining the risk factors for hip fracture in the Indian population. Methods We carried out a case control investigation comprising 100 case subjects (57 women and 43 men admitted with a first hip fracture into one of three hospitals across New Delhi. The 100 controls were age and sex matched subjects who were either healthy visitors not related to the case patients or hospital staff. Information from all subjects was obtained through a questionnaire based interview. Results There was a significant increase in the number of cases of hip fracture with increasing age. There were significantly more women (57% than men (43%. Univariate analysis identified protective effects for increased activity, exercise, calcium and vitamin supplements, almonds, fish, paneer (cottage cheese, curd (plain yogurt, and milk. However, tea and other caffeinated beverages were significant risk factors. In women, hormone/estrogen therapy appeared to have a marginal protective effect. For all cases, decreased agility, visual impairment, long term medications, chronic illnesses increased the risk of hip fracture. The multivariate analysis confirmed a protective effect of increased activity and also showed a decrease in hip fracture risk with increasing body mass index (odds ratio (OR 0.024, 95% confidence interval (CI 0.006-0.10 & OR 0.81, 95% CI 0.68-0.97 respectively. Individuals who take calcium supplements have a decreased risk of hip fracture (OR 0.076; CI 0.017-0.340, as do individuals who eat fish (OR 0.094; CI 0.020-0.431, and those who eat paneer (OR 0.152; 0.031-0.741. Tea drinkers have a higher risk of hip fracture (OR 22.8; 95% CI 3.73-139.43. Difficulty in getting up from a chair also appears to be an important risk factor for hip fractures (OR 14.53; 95% CI 3.86-54.23. Conclusions In the urban Indian population, dietary calcium, vitamin D

  8. Role of Intraoperative Radiographs in the Surgical Treatment of Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Vidal, Christophe; Ilharreborde, Brice; Queinnec, Steffen; Mazda, Keyvan

    2016-03-01

    One of the main goals of scoliosis surgery is to obtain a balanced fused spine. Although preoperative planning remains essential, intraoperative posteroanterior radiographs are the only available tool during the procedure to verify shoulder and coronal spinal balance and, if necessary, adjust the construct. The aim of this study was to quantify the direct influence of intraoperative radiographs on the surgical procedure itself during correction of adolescent idiopathic scoliosis. Retrospective analysis of prospectively collected data on a monocentric cohort of adolescent idiopathic scoliosis patients undergoing corrective surgery. A total 148 consecutive patients operated in the same department following the same validated preoperative planning method were included in this prospective radiologic study. The mean follow-up averaged 33 months. Frontal Cobb angles, T1 tilt, shoulder tilt, iliolumbar angle, and frontal balance were measured and compared on intraoperative, early postoperative, and latest follow-up radiographs. Any intraoperative modification of the correction performed after analysis of the intraoperative radiograph were recorded. The analysis of all radiologic parameters was possible in 90.5% of the cases. In 9.5% of the cases, shoulders could not be properly distinguished. Significant modifications on the upper thoracic curve to correct T1 tilt or shoulder balance were performed in 29% of the patients, and changes at the distal levels were recorded in 19%, underlining planification imperfections. On postoperative standing radiographs, the average coronal parameters were neutral, without loss of correction at follow-up. Intraoperative radiographs remain necessary to ensure compensation of the shortcomings of the modern preoperative planification method.

  9. Bilateral simultaneous femoral neck and shafts fractures - a case report.

    Science.gov (United States)

    Sadeghifar, Amirreza; Saied, Alireza

    2014-10-01

    Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression plate and both necks were fixed using 6.5 mm cannulated screws. Femur fixation on one side was converted to retrograde nailing because of plate failure. Both neck fractures healed uneventfully. In spite of rarity of concomitant fractures of femoral neck and shaft, this injury must be approached carefully demanding especial attention and careful device selection.

  10. A Case Series of Rapid Prototyping and Intraoperative Imaging in Orbital Reconstruction

    Science.gov (United States)

    Lim, Christopher G.T.; Campbell, Duncan I.; Cook, Nicholas; Erasmus, Jason

    2014-01-01

    In Christchurch Hospital, rapid prototyping (RP) and intraoperative imaging are the standard of care in orbital trauma and has been used since February 2013. RP allows the fabrication of an anatomical model to visualize complex anatomical structures which is dimensionally accurate and cost effective. This assists diagnosis, planning, and preoperative implant adaptation for orbital reconstruction. Intraoperative imaging involves a computed tomography scan during surgery to evaluate surgical implants and restored anatomy and allows the clinician to correct errors in implant positioning that may occur during the same procedure. This article aims to demonstrate the potential clinical and cost saving benefits when both these technologies are used in orbital reconstruction which minimize the need for revision surgery. PMID:26000080

  11. A case series of rapid prototyping and intraoperative imaging in orbital reconstruction.

    Science.gov (United States)

    Lim, Christopher G T; Campbell, Duncan I; Cook, Nicholas; Erasmus, Jason

    2015-06-01

    In Christchurch Hospital, rapid prototyping (RP) and intraoperative imaging are the standard of care in orbital trauma and has been used since February 2013. RP allows the fabrication of an anatomical model to visualize complex anatomical structures which is dimensionally accurate and cost effective. This assists diagnosis, planning, and preoperative implant adaptation for orbital reconstruction. Intraoperative imaging involves a computed tomography scan during surgery to evaluate surgical implants and restored anatomy and allows the clinician to correct errors in implant positioning that may occur during the same procedure. This article aims to demonstrate the potential clinical and cost saving benefits when both these technologies are used in orbital reconstruction which minimize the need for revision surgery.

  12. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint

    OpenAIRE

    Woods, Michael; Birkholz, Denise; MacBarb, Regina; Capobianco, Robyn; Woods, Adam

    2014-01-01

    Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis) and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct...

  13. The correlation of the morphological changes of ankle point and ankle joint function after surgery on the Ruedi-Allgouer type III Pilon fracture: A case series study.

    Science.gov (United States)

    Zhou, Yifei; Cai, Leyi; Lu, Xiaolang; Yu, Yang; Hong, Jianjun

    2017-08-01

    To analyze the relationship between imaging findings and postoperative curative effect by measuring the morphology of the ankle mortise in patients with the Ruedi-Allgouer type III Pilon fractures. Forty-seven patients with Ruedi-Allgouer type III Pilon fractures who underwent surgical treatment from January 2011 to January 2015 were retrospectively analyzed. At the last follow-up, x-rays of the affected ankle and the healthy side were measured. According to the Kitaoka score of ankle joint function at the last follow-up. All patients were followed up for 18-24 months (mean 21 months). This study demonstrated that compared with the healthy side, the index of the width, depth, and coronal/sagittal angles of the ankle mortise were significantly different (P  0.05). According to the Kitaoka score, the difference between the affected and the healthy sides of each index of the ankle mortise was compared between the 3 groups. That is, the intraoperative treatment of the width and depth of the ankle mortise as well as the coronal and sagittal angles of the ankle mortise were significantly correlated with the postoperative curative effect. The intraoperative treatment of ankle mortise width, depth, and ankle coronal/sagittal angle in patients with severe Pilon fractures has a significant impact on postoperative efficacy. In order to prevent the occurrence of traumatic arthritis, the anatomical morphology of the ankle should be restored as much as possible in the course of surgery. Copyright © 2017. Published by Elsevier Ltd.

  14. A case of hypotension after intranasal adrenaline infiltration causing a clinical dilemma during the intraoperative period

    Directory of Open Access Journals (Sweden)

    Shyam Bhandari

    2011-01-01

    Full Text Available Solutions containing adrenaline are widely used for presurgical infiltration. Haemodynamic changes associated with its use are well documented in the literature. Prolonged intraoperative hypotension after subcutaneous infiltration of diluted adrenaline is an uncommon scenario. We believe that our case of the prolonged episode of hypotension was secondary to infiltration of nasal septum with a high concentration of adrenaline. As β2 receptor activation leads to skeletal muscle vasodilation, a decrease in preload may have lead to profound hypotension. Postoperatively, the patient was examined and any autonomic or endocrinological pathology was ruled out.

  15. Treatment for Trochanteric Fracture of the Femur with Short Femoral Nail: A Comparison between the Asian Intramedullary Hip Screw (IMHS) and the Conventional IMHS.

    Science.gov (United States)

    Kawaji, Hidemi; Uematsu, Takuya; Oba, Ryosuke; Satake, Yoshihiko; Hoshikawa, Naoya; Takai, Shinro

    2016-01-01

    We usually use short femoral nails for the treatment of trochanteric fracture of the femur. In this retrospective study, we investigated and compared the clinical results of the conventional intramedullary hip screw (IMHS) and the Asian IMHS, which is a redesigned version of the former. The subjects were 42 patients; 21 treated with the Asian IMHS and 21 were treated with the conventional IMHS. From the clinical records, we retrospectively investigated the patients' age, sex, in-hospital waiting period for operation, operating time, intraoperative blood loss, walking ability before fracture and at discharge, and complication pertaining to the operation. The 21 patients (4 men and 17 women) receiving the Asian IMHS and the 21 patients (5 men and 16 women) receiving the conventional IMHS did not differ significantly in mean age, sex ratio, preoperative waiting period, mean postoperative hospital stay, mean operation time, or mean intraoperative blood loss. Among patients receiving the Asian IMHS, the complications of intraoperative fractures of the femur developed in 3 patients and breakage of the implant occurred in 1 patient. No complications occurred in patients receiving the conventional IMHS. Compared with the conventional IMHS, the Asian IMHS is smaller, has increased variations in the shaft/neck angle of the lag screw, and has a titanium-alloy construction, allowing magnetic resonance imaging. The intraoperative fracture may have occurred because of the configuration of the distal interlocking screw in the Asian IMHS. Breakage of the implant likely occurred because the nail was too small in diameter, and too short in length for the unstable AO 31-A3 fracture. If careful attention is paid to the configuration of its distal interlocking screw intraoperatively and a nail of appropriate size is selected, the Asian IMHS is better suited than the conventional IMHS for treating Japanese patients, who generally have a small physique, because of its many variations in

  16. Optically neuronavigated ultrasonography in an intraoperative magnetic resonance imaging environment.

    Science.gov (United States)

    Katisko, Jani P A; Koivukangas, John P

    2007-04-01

    To develop a clinically useful method that shows the corresponding planes of intraoperative two-dimensional ultrasonography and intraoperative magnetic resonance imaging (MRI) scans determined with an optical neuronavigator from an intraoperative three-dimensional MRI scan data set, and to determine the qualitative and the quantitative spatial correspondence between the ultrasonography and MRI scans. An ultrasound probe was interlinked with an ergonomic and MRI scan-compatible ultrasonography probe tracker to the optical neuronavigator used in a low-field intraoperative MRI scan environment for brain surgery. Spatial correspondence measurements were performed using a custom-made ultrasonography/MRI scan phantom. In this work, instruments to combine intraoperatively collected ultrasonography and MRI scan data with an optical localization method in a magnetic environment were developed. The ultrasonography transducer tracker played an important role. Furthermore, a phantom for ultrasonography and MRI scanning was produced. This is the first report, to our knowledge, regarding the possibility of combining the two most important intraoperative imaging modalities used in neurosurgery, ultrasonography and MRI scanning, to guide brain tumor surgery. The method was feasible and, as shown in an illustrative surgical case, has direct clinical impact on image-guided brain surgery. The spatial deviation between the ultrasonography and the MRI scans was, on average, 1.90 +/- 1.30 mm at depths of 0 to 120 mm from the ultrasonography probe. The overall result of this work is a unique method to guide the neurosurgical operation with neuronavigated ultrasonography imaging in an intraoperative MRI scanning environment. The relevance of the method is emphasized in minimally invasive neurosurgery.

  17. [Treatment of periprosthetic femoral fractures after total hip arthroplasty with specially constructed retrograde hollow nails].

    Science.gov (United States)

    Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U

    2014-12-01

    Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and

  18. Comminuted distal femur closed fractures: a new application of the Ilizarov concept of compression-distraction.

    Science.gov (United States)

    El-Tantawy, Ahmad; Atef, Ashraf

    2015-04-01

    The treatment of intra-articular distal femur fractures with severe metaphyseal comminution is challenging. It is important to choose a technique that provides secure fixation, minimum tissue handling, and early ambulation. The aim of this work was to evaluate the outcomes of application of Ilizarov concept as an early definitive treatment of comminuted distal femur closed fractures. A total of 17 male patients (mean age 28.53±6.33 years) presented with comminuted distal femur fractures (with 10 type C2 and 7 type C3-2 fractures according to AO/ASIF system) were included in this prospective study. Initial fixation of the articular fragments was done by inter-fragmentary screws, percutaneously through a limited open approach, and stabilization was completed by Ilizarov fixator. The procedure included acute shortening, through the comminution, followed by gradual re-distraction to compensate the created shortening. Radiological and functional results were assessed according to ASAMI evaluation system. The mean amount of intra-operative shortening was 3.68±0.53 cm. The mean external fixation index was 37.24±2.53 days/cm. The mean follow-up period was 18.18±1.91 months. All fractures united primarily in an average 137.65±4.12 days, with no evident angular deformity or limb-length discrepancy. None of the cases required a second major procedure or bone graft. The functional results were excellent in three cases, good in 12, and fair in two patients. The Ilizarov concept of acute compression-distraction is a valuable alternative for the treatment of distal femur fractures with severe metaphyseal comminution.

  19. Ideal Timing of Starting Weight-Bearing After Calcaneal Insufficiency Fracture: A Case Report and Review of the Literature

    OpenAIRE

    Imamura; Mochizuki; Kawakami; Momohara

    2016-01-01

    Introduction Criteria for starting weight-bearing on the heel with a symptomatic calcaneal insufficiency fracture have not yet been reported. Case Presentation We describe a rare case of a 52-year-old woman with a calcaneal insufficiency fracture who sustained a second ipsilateral calcaneal insufficiency fracture within a short time span. The initial fracture was not evident radiographically, but was detected using magnetic resona...

  20. Intraoperative radiation therapy

    International Nuclear Information System (INIS)

    Dobelbower Junior, R.R.

    1987-01-01

    A briefly history of intraoperative radiotherapy is presented. The equipment used is described and the treatment with superficial X-ray beams, orthovoltage X-ray beams and megavoltage electron beams are discussed. The effect on normal tissues and the clinical use of intraoperative radiotherapy in several Kind of cancer is studied. (M.A.C.) [pt

  1. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. Odontoid fracture that is not listed in the existing classifications A new subtype of odontoid fracture: case report

    Directory of Open Access Journals (Sweden)

    Adam D.

    2016-03-01

    Full Text Available Background: There is a significant variety of odontoid fracture classifications along with corresponding treatment strategies. There are though cases which cannot be framed within the existing classifications.

  3. [Surgery of ipsilateral Hawkins Ⅲ talus neck and ankle joint fractures via internal and lateral approaches with Herbert screws].

    Science.gov (United States)

    Zhang, P; Dong, Q R; Wang, Z Y; Chen, B; Wan, J H; Wang, L

    2016-11-08

    Objective: To explore the manual operation skills of operative treatment of ipsilateral Hawkins Ⅲ talus neck and ankle joint fractures via internal and lateral approaches with Herbert screws, and to study the clinical results. Method: From Jan 2009 to Dec 2014, the clinical data of 13 patients with ipsilateral Hawkins Ⅲ talus neck and ankle joint fractres via internal and lateral approaches with Herbert screws were retrospectively analyzed in our department.There were 10 males and 3 female, ranging in age from 20 to 60 years with an average age of 31.5 years.The fractures occurred on the right side in 9 patients and on the left side in 4 patients.Three cases had the complication of medial malleolar fracture.Ten cases had the complication of medial and lateral malleolar fracture. Totally 11 cases were made calcaneal skeletal traction, and all the were made CT with three-dimensional image reconstruction.Two cases were treated with emergency operation.Eleven cases were treated with selective operation.The operation time was 5 hours-10 days after injury. The functional results were evaluated by American Orthopaedic Foot and Ankle Society (AOFAS). Result: The average duration of follow-up was 22.6 months (range, 14-65 months). There was skin necrosis in one cases, no incision infection, malunion and nonunion of the fractures and loss of reduction. At final follow-up, AOFAS ankle score was 75.2 (range, 42 to 93), higher than preoperative 39.2 (range, 23 to 60), the difference was statistically significant ( P =0.023). The result was excellent in 4 cases, good in 5 cases, fair in 3 cases and 1 cases in poor, and the overall excellent or good rate was 69.2%. Avascular necrosis occurred in 3 cases (23.1%, 3/13). Traumatic arthritis was found in 5 cases (38.5%, 5/13), involved tibial astragaloid joint in 2 cases, involved subtalar joint in 1 case, involved tibial astragaloid joint and subtalar joint in 2 cases. Conclusion: The effect of surgical treatment for ipsilateral

  4. Case report: clinical and postmortem findings in four cows with rib fracture.

    Science.gov (United States)

    Braun, Ueli; Warislohner, Sonja; Hetzel, Udo; Nuss, Karl

    2017-02-06

    Published reports of rib fractures in adult cattle are limited to the occurrence of chronic rib swellings caused by calluses, which are unremarkable from a clinical standpoint, whereas studies identifying clinical signs of rib fractures were not found in a literature search. This report describes the clinical and postmortem findings in four cows with rib fractures. The 13th rib was fractured in three cows and the 11th rib in the remaining cow; three fractures were on the right and one on the left side. Clinical and postmortem findings varied considerably, and percussion of the rib cage elicited a pain response in only one cow. One cow had generalised peritonitis because of perforation of the rumen by the fractured rib. One cow was recumbent because of pain and became a downer cow, and two other cows had bronchopneumonia, which was a sequel to osteomyelitis of the fracture site in one. In the absence of a history of trauma, the diagnosis of rib fracture based on clinical signs alone is difficult. Although rib fractures undoubtedly are very painful, the four cases described in this report suggest that they are difficult to diagnose in cattle because associated clinical signs are nonspecific.

  5. Clinical study on the application of minimally invasive percutaneous pedicle screw fixation in single segment thoracolumbar fracture without neurological symptoms

    Directory of Open Access Journals (Sweden)

    Jin-ping LIU

    2016-04-01

    Full Text Available Objective To discuss the clinical effects of minimally invasive percutaneous pedicle screw fixation in the treatment of single segment thoracolumbar fracture without neurological symptoms.  Methods From June 2012 to October 2014, 38 neurologically intact patients with thoracolumbar fracture underwent surgeries, including open pedicle screw fixation in 16 cases and percutaneous pedicle screw fixation in 22 cases. The incision length, operation time, intraoperative blood loss, postoperative drainage and postoperative complication were recorded and compared between 2 groups. Thoracolumbar orthophoric, lateral and flexion-extension X-ray was used to measure sagittal Cobb angle and height of injured anterior vertebral body before and after operation. Modified Macnab evaluation was used to assess the curative effects 3 months after operation. Results The success rate of operations in 38 patients was 100%. There were a total of 114 vertebral bodies fused and 228 pedicle screws implanted. Patients in the percutaneous pedicle screw group had smaller incision length [(10.55 ± 1.23 cm vs (18.50 ± 2.50 cm, P = 0.000], less intraoperative blood loss [(32.55 ± 7.22 ml vs (320.50 ± 15.48 ml, P = 0.000], shorter hospital stay [(6.55 ± 1.50 d vs (13.50 ± 2.52 d, P = 0.000], and without postoperative drainage. The follow-up after operation ranged from 3 to 6 months, with the average time of (4.65 ± 1.24 months. Cobb angle was reduced (P = 0.000 and height of injured anterior vertebral body were improved signifcantly (P = 0.000 3 months after surgery in both groups. The total effective rate was 14/16 in open surgery group, and 86.36% (19/22 in percutaneous pedicle screw group, however, the difference between 2 groups was not significant (P = 1.000. Conclusions Minimally invasive percutaneous pedicle screw fixation is a surgical method with less iatrogenic injury, less intraoperative blood loss and quick recovery for patients with thoracolumbar fracture

  6. Alignment After Intramedullary Nailing of Distal Tibia Fractures Without Fibula Fixation.

    Science.gov (United States)

    De Giacomo, Anthony F; Tornetta, Paul

    2016-10-01

    To evaluate the efficacy of intramedullary nailing of distal tibia fractures using modern techniques, without fibula fixation, in obtaining and maintaining alignment. Retrospective case review. Level-I academic trauma center. One hundred thirty-two consecutive patients with distal tibia fractures. Intramedullary nail of distal tibia fracture, without fibula fixation, was performed in consecutive patients using modern reduction techniques. Malalignment and malunion were defined as >5 degrees of varus/valgus angulation or anterior/posterior angulation on the initial postoperative or final anteroposterior and lateral x-rays. There were 122 consecutive patients (86 men and 36 women) 16-93 years of age (average, 43 years) with 36 (30%) open and 85 (70%) closed fractures with complete follow-up. Mechanism of injury did not predict the presence or level of fibula fracture. Upon presentation, varus/valgus and procurvatum/recurvatum angulation was greatest when the fibula was fractured at the level of the tibia fracture (P = 0.001 and 0.028). The most common intraoperative reduction aids were nailing in relative extension, transfixion external fixation, and clamps at the fracture site. The OTA fracture type or level/presence of fibula fracture did not influence malalignment (P = 0.86 and 0.66), malunion (P = 0.81 and 0.79), or the change in alignment during union, which averaged 0.9 degrees. We found an overall low rate of both malalignment (2%) and malunion (3%) after intramedullary nailing of distal tibial shaft fracture without fibula fixation. We conclude that when modern nailing techniques are used, which allow for confirmation of reduction by visualization in fluoroscopy, from nail placement to distal interlocking, fibula fixation is not necessary to obtain or maintain alignment. Furthermore, standard 2 medial to lateral screws distally afford adequate stability to hold the reduction during union with a 0.9-degree difference in the initial postoperative and final

  7. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint.

    Science.gov (United States)

    Woods, Michael; Birkholz, Denise; MacBarb, Regina; Capobianco, Robyn; Woods, Adam

    2014-01-01

    Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis) and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct to minimally invasive pedicle screw placement. The utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion using a series of triangular, titanium porous plasma coated implants has not been evaluated. Methods. A medical chart review of consecutive patients treated with minimally invasive surgical sacroiliac joint fusion was undertaken at a single center. Baseline patient demographics and medical history, intraoperative electromyography thresholds, and perioperative adverse events were collected after obtaining IRB approval. Results. 111 implants were placed in 37 patients. Sensitivity of EMG was 80% and specificity was 97%. Intraoperative neuromonitoring potentially avoided neurologic sequelae as a result of improper positioning in 7% of implants. Conclusions. The results of this study suggest that intraoperative neuromonitoring may be a useful adjunct to minimally invasive surgical sacroiliac joint fusion in avoiding nerve injury during implant placement.

  8. Utility of Intraoperative Neuromonitoring during Minimally Invasive Fusion of the Sacroiliac Joint

    Directory of Open Access Journals (Sweden)

    Michael Woods

    2014-01-01

    Full Text Available Study Design. Retrospective case series. Objective. To document the clinical utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion for patients diagnosed with sacroiliac joint dysfunction (as a direct result of sacroiliac joint disruptions or degenerative sacroiliitis and determine stimulated electromyography thresholds reflective of favorable implant position. Summary of Background Data. Intraoperative neuromonitoring is a well-accepted adjunct to minimally invasive pedicle screw placement. The utility of intraoperative neuromonitoring during minimally invasive surgical sacroiliac joint fusion using a series of triangular, titanium porous plasma coated implants has not been evaluated. Methods. A medical chart review of consecutive patients treated with minimally invasive surgical sacroiliac joint fusion was undertaken at a single center. Baseline patient demographics and medical history, intraoperative electromyography thresholds, and perioperative adverse events were collected after obtaining IRB approval. Results. 111 implants were placed in 37 patients. Sensitivity of EMG was 80% and specificity was 97%. Intraoperative neuromonitoring potentially avoided neurologic sequelae as a result of improper positioning in 7% of implants. Conclusions. The results of this study suggest that intraoperative neuromonitoring may be a useful adjunct to minimally invasive surgical sacroiliac joint fusion in avoiding nerve injury during implant placement.

  9. Evaluation of Transsyndesmotic Fixation and Primary Deltoid Ligament Repair in Ankle Fractures With Suspected Combined Deltoid Ligament Injury.

    Science.gov (United States)

    Wu, Kai; Lin, Jian; Huang, Jianhua; Wang, Qiugen

    2018-04-13

    The present prospective study examined the utility of the intraoperative tap test/technique for distal tibiofibular syndesmosis in the diagnosis of deltoid ligament rupture and compared the outcomes of transsyndesmotic fixation to deltoid ligament repair with suture anchor. This diagnostic technique was performed in 59 ankle fractures with suspected deltoid ligament injury. The width of the medial clear space of 59 cases was evaluated to assess the sensitivity and specificity. Those with deltoid ligament rupture were randomly assigned to 2 groups and treated with deltoid ligament repair with a suture anchor or with syndesmosis screw fixation. All the patients were assessed with the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale, short-form 36-item questionnaire (SF-36), and visual analog scale (VAS). The tap test was positive in 53 cases. However, surgical exploration demonstrated that 51 cases (86.4%) had a combined deltoid ligament injury and fracture. The sensitivity and specificity of the tap test was 100.0% and 75.0%, respectively. Finally, 26 cases (96.3%) in the syndesmosis screw group and 22 (91.7%) in the deltoid repair group were followed up. No statistically significant differences were found in the AOFAS ankle-hindfoot scale score, SF-36 score, or VAS score between the 2 groups. The malreduction rate in the syndesmosis screw group was 34.6% and that in the deltoid repair group was 9.09%. The tap test is an intraoperative diagnostic method to use to evaluate for deltoid ligament injury. Deltoid ligament repair with a suture anchor had good functional and radiologic outcomes comparable to those with syndesmotic screw fixation but has a lower malreduction rate. We did not encounter the issue of internal fixation failure or implant removal. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Bilateral Stress Fractures of the Femoral Neck from Renal Osteomalacia: A Case Report

    Directory of Open Access Journals (Sweden)

    S Sengupta

    2008-04-01

    Full Text Available A rare case of spontaneous bilateral stress fractures of femoral neck leading to coxa vara in a young female with history of chronic renal disease and secondary osteomalacia is described. Once the underlying disease was controlled, the fracture was treated by valgus osteotomy with good result.

  11. Preoperative Evaluation and Endovascular Procedure of Intraoperative Aneurysm Rupture During Thoracic Endovascular Aortic Repair

    Energy Technology Data Exchange (ETDEWEB)

    Zha, Bin-Shan, E-mail: binszha2013@163.com; Zhu, Hua-Gang, E-mail: huagzhu@yeah.net; Ye, Yu-Sheng, E-mail: yeyusheng@aliyun.com; Li, Yong-Sheng, E-mail: 872868848@qq.com; Zhang, Zhi-Gong, E-mail: zzgedward@sina.com; Xie, Wen-Tao, E-mail: 345344347@qq.com [The First Affiliated Hospital of Anhui Medical University, Department of Vascular Surgery (China)

    2017-03-15

    Thoracic aortic aneurysms are now routinely repaired with endovascular repair if anatomically feasible because of advantages in safety and recovery. However, intraoperative aneurysm rupture is a severe complication which may have an adverse effect on the outcome of treatment. Comprehensive preoperative assessment and considerate treatment are keys to success of endovascular aneurysm repair, especially during unexpected circumstances. Few cases have reported on intraoperative aortic rupture, which were successfully managed by endovascular treatment. Here, we present a rare case of an intraoperative aneurysm rupture during endovascular repair of thoracic aortic aneurysm with narrow neck and angulated aorta arch (coarctation-associated aneurysm), which was successfully treated using double access route approach and iliac limbs of infrarenal devices.Level of EvidenceLevel 5.

  12. Rapid intraoperative tissue expansion with Foley catheter in a challenging cripple Hypospadias

    Directory of Open Access Journals (Sweden)

    Murat Cakmak

    2015-06-01

    Full Text Available ABSTRACTFailed hypospadiass cases may result in hypovascular, scarred penis with residual penile chordee and leave the patient with minimal residual skin for penile resurfacing and urethroplasty. Local tissue expansion has become a good alternative to provide skin for penis by using expanders however they require long periods of time for expansion. Besides, rapid tissue expansion was also described in different tissues. We used rapid intraoperative expansion technique by using a Foley catheter in a failed hypospadias case who had minimal residual skin secondary to infection and we concluded that rapid intraoperative tissue expansion with Foley catheter is an effective, feasible reconstructive method for easy dissection and penile resurfacing in failed hypospadiass cases.

  13. Role of scrape cytology in the intraoperative diagnosis of tumor

    Directory of Open Access Journals (Sweden)

    Kolte Sachin

    2010-01-01

    Full Text Available Background : Rapid diagnosis of surgically removed specimens has created many controversies and a single completely reliable method has not yet been developed. Histopathology of a paraffin section remains the ultimate gold standard in tissue diagnosis. Frozen section is routinely used by the surgical pathology laboratories for intraoperative diagnosis. The use of either frozen section or cytological examination alone has an acceptable rate (93-97% of correct diagnosis, with regard to interpretation of benign versus malignant. Aim : To evaluate the utility of scrape cytology for the rapid diagnosis of surgically removed tumors and its utilisation for learning cytopathology. Materials and Methods : 75 surgically removed specimens from various organs and systems were studied. Scrapings were taken from each specimen before formalin fixation and stained by modified rapid Papanicolaou staining. Results : Of the 75 cases studied, 73 could be correctly differentiated into benign and malignant tumors, with an accuracy rate of 97.3%. Conclusions : Intraoperative scrape cytology is useful for intraoperative diagnosis of tumor, where facilities for frozen section are not available. The skill and expertise developed by routinely practicing intraoperative cytology can be applied to the interpretation of fine needle aspirate smears. Thus, apart from its diagnostic role, intraoperative cytology can become a very useful learning tool in the field of cytopathology.

  14. Bilateral Subpectoral Interfascial Plane Catheters for Analgesia for Sternal Fractures: A Case Report.

    Science.gov (United States)

    Raza, Irfan; Narayanan, Madankumar; Venkataraju, Arun; Ciocarlan, Alexandra

    2016-01-01

    Sternal fractures occur after deceleration injuries such as falls and road traffic accidents. Recovery from isolated fractures is excellent, but mortality increases dramatically with concurrent chest injuries such as rib fractures and soft tissue injuries. Short-term complications include chest pain, which prevents patients from taking deep breaths and coughing, thereby predisposing them to chest infections. We present a case of a 73-year-old woman with sternal fracture in whom enteral analgesia was inadequate and who was intolerant to intravenous opiates. The patient was successfully treated with a continuous infusion of local anesthetic into the subpectoral interfascial plane. We also discuss the use and potential benefits of the subpectoral interfascial plane block in the treatment of pain from sternal fractures.

  15. Bilateral Tibial Stress Fractures in a Young Man Associated with Idiopathic Osteoporosis - Case Report

    Directory of Open Access Journals (Sweden)

    Selahattin Özyürek

    2010-12-01

    Full Text Available Stress fractures are defined as a partial or complete fracture of bone due to an inability to endure a non-violent stress. Two factors have been proposed to explain the aetiology of stress fractures: muscle fatigue, and direct muscle action. We want to point to third factor with our case report: Osteoporosis. (From the World of Osteoporosis 2010;16:58-60

  16. Intraoperative computed tomography for cervicomedullary decompression of foramen magnum stenosis in achondroplasia: two case reports.

    Science.gov (United States)

    Arishima, Hidetaka; Tsunetoshi, Kenzo; Kodera, Toshiaki; Kitai, Ryuhei; Takeuchi, Hiroaki; Kikuta, Ken-Ichiro

    2013-01-01

    The authors report two cases of cervicomedullary decompression of foramen magnum (FM) stenosis in children with achondroplasia using intraoperative computed tomography (iCT). A 14-month-old girl with myelopathy and retarded motor development, and a 10-year-old girl who had already undergone incomplete FM decompression was presented with myelopathy. Both patients underwent decompressive sub-occipitalcraniectomy and C1 laminectomy without duraplasty using iCT. It clearly showed the extent of FM decompression during surgery, which finally enabled sufficient decompression. After the operation, their myelopathy improved. We think that iCT can provide useful information and guidance for sufficient decompression for FM stenosis in children with achondroplasia.

  17. A hypoplastic patella fracture in nail patella syndrome: a case report

    LENUS (Irish Health Repository)

    Neill, Shane C O

    2012-07-16

    AbstractIntroductionNail patella syndrome is a rare autosomal dominant hereditary condition, with an incidence of 22 per million in the United Kingdom. The syndrome’s most common features include iliac horns, hypoplastic patella and nail dysplasia.Case presentationWe report the case of a 26-year-old Caucasian man with nail patella syndrome who sustained a fracture of his right hypoplastic patella after a fall. His right knee became swollen and he was unable to extend against gravity immediately post fall. Radiographs revealed a fracture of the lower pole of his right patella with associated complete disruption of the extensor mechanism of the knee. He underwent operative fixation and his post operative course was uneventful. He was further treated post operatively with a full knee cast and graded immobilization. At six months he had regained the full range of motion at the knee joint.ConclusionsTo the best of our knowledge, this is the only case report in the literature describing a patella fracture in an individual with nail patella syndrome. We hypothesize that given the extent of pre-existing knee joint impairment in these individuals, functional outcome may be inferior, suggesting the need for more frequent follow-up.

  18. Intrathoracic fracture-dislocation of the humerus - case report and literature review

    Directory of Open Access Journals (Sweden)

    Wilson Carlos Sola Junior

    Full Text Available ABSTRACT Shoulder fracture-dislocations are uncommon. Those associated with intrathoracic dislocation are very rare conditions, resulting from high-energy trauma; usually, the affected limb is in an abduction position. In Brazil, there is only one report of a teenager with displacement of the epiphysis into the chest cavity; the present is the first adult patient report of intrathoracic dislocation of the humerus. The authors present the case of a patient female, aged 56 years, who was hit by motorcycle and thrown approximately 5 meters away. She was rescued on site with thoracic, pelvic, and right upper limb trauma. Her chest was drained due to pneumothorax and multiple fractures of ribs; she was diagnosed with fracture-dislocation in four parts, with intrathoracic dislocation of the humeral head. Displaced forearm bones fracture was also diagnosed; the olecranon, scaphoid, and ischiopubic fractures were not displaced. The patient underwent a joint procedure with a cardiothoracic surgery team to remove the humeral head through thoracotomy and chest drainage; subsequently, a partial arthroplasty of the humerus was performed, with graft from the humeral head and fixation of forearm fractures. Conservative treatment was chosen for the other fractures. After three months, all fractures were healed with gradual functional improvement. The patient remained in physiotherapy and orthopedic monitoring, having been discharged from the thoracic surgery; in a severe depressive episode, the patient committed suicide after 11 months of the trauma.

  19. Minimally Invasive Spinal Surgery with Intraoperative Image-Guided Navigation

    Directory of Open Access Journals (Sweden)

    Terrence T. Kim

    2016-01-01

    Full Text Available We present our perioperative minimally invasive spine surgery technique using intraoperative computed tomography image-guided navigation for the treatment of various lumbar spine pathologies. We present an illustrative case of a patient undergoing minimally invasive percutaneous posterior spinal fusion assisted by the O-arm system with navigation. We discuss the literature and the advantages of the technique over fluoroscopic imaging methods: lower occupational radiation exposure for operative room personnel, reduced need for postoperative imaging, and decreased revision rates. Most importantly, we demonstrate that use of intraoperative cone beam CT image-guided navigation has been reported to increase accuracy.

  20. Occult posterolateral rotatory dislocation of the elbow with olecranon fracture in a child: a case report

    Directory of Open Access Journals (Sweden)

    Fujimori Takahito

    2012-09-01

    Full Text Available Abstract Introduction Acute posterolateral rotator elbow dislocation in a child is rare and can be easily misdiagnosed due to immaturity of the epiphysis. This is the first case of occult posterolateral rotator elbow dislocation in combination with an olecranon fracture. We report our experience with this case, which was not diagnosed correctly by plain radiographs. Case presentation An 11-year-old Asian boy suffered severe pain and swelling of his right elbow after his outstretched arm hit a car dashboard in a motor vehicle accident. Plain radiographs showed only a minimally displaced olecranon fracture and a tiny lateral epicondylar avulsion fracture. However, stress radiographs under general anesthesia revealed severe posterolateral rotatory instability. During surgery, we found that the cartilaginous lateral epicondylar apophysis was much larger than the epicondylar fragment on the radiographs. After the lateral epicondylar osteochondral fragment and lateral collateral ligament complex were fixed, the instability disappeared. Conclusion Our experience with this case shows that it is important to check for instability with pediatric elbow fractures, because a tiny avulsion fracture was able to cause severe posterolateral rotatory instability in a child.

  1. Fractures of the third trochanter in horses: 8 cases (2000-2012).

    Science.gov (United States)

    Bertoni, Lélia; Seignour, Maeva; de Mira, Monica C; Coudry, Virginie; Audigie, Fabrice; Denoix, Jean-Marie

    2013-07-15

    To determine history; clinical, radiographic, ultrasonographic, and scintigraphic features; management; and outcome associated with third trochanter fractures in horses. Retrospective case series. 8 horses. Records from 2000 to 2012 were reviewed, and signalment, case history, severity and duration of lameness, results of physical and lameness examinations, imaging findings, management, and outcome were evaluated. All horses had a history of acute onset of severe lameness. Four of the 8 horses had localizing physical signs of fracture. No specific gait characteristics were identified. Ultrasonographically, there was a single bony fragment displaced cranially in 7 of 8 horses and multiple bony fragments in 1. Concurrent gluteus superficialis muscle enthesopathy was identified in 7 horses. A standing craniolateral-caudomedial 25° oblique radiographic view was obtained in 3 horses to document the lesion and revealed in all 3 horses a simple complete longitudinal fracture between the midlevel and the base of the third trochanter. Nuclear scintigraphy was used to identify the affected area of the limb for further examination in 2 horses. Follow-up revealed that fractures healed with a fibrous union, with persistence of cranial displacement of the fragment. Lameness resolved after nonsurgical management for all horses. Fracture of the third trochanter should be considered as a cause of hind limb lameness in horses when the proximal portion of the limb is affected. Diagnosis can easily be made with ultrasonography, but nuclear scintigraphy may help in identifying the lesion. Prognosis for return to athletic activity is good after an appropriate period of rest and restricted exercise.

  2. Bilateral undisplaced insufficiency neck of femur fractures associated with short-term steroid use: a case report

    Directory of Open Access Journals (Sweden)

    Gurdezi Sabahat

    2008-03-01

    Full Text Available Abstract Introduction We present an interesting and unusual case of a 61-year-old woman with bilateral, undisplaced, stress neck of femur fractures associated with short-term steroid use. Insufficiency fractures of the neck of femur without preceding trauma have been described in the literature, although bilateral involvement is infrequent. These fractures have been associated with strenuous exercise, seizures, renal osteodystrophy, fluoride treatment, long-term corticosteroid use, amenorrhoea, abnormal anatomy and osteomalacia due to nutritional and/or hormonal factors. Case Presentation The case we present differs from other published reports, in that the patient's symptoms developed acutely after only a short course of steroids and with no associated trauma or strenuous exercise. It is also the only case described where no operative intervention was required. Conclusion Our case reiterates the importance of considering insufficiency or stress fractures in high-risk patients who present with musculoskeletal pain. Institution of bone protection should also be considered in these patients. Morbidity related to delayed treatment has been well documented, so a high level of clinical suspicion is imperative.

  3. Surgical treatment of refractory tibial stress fractures in elite dancers: a case series.

    Science.gov (United States)

    Miyamoto, Ryan G; Dhotar, Herman S; Rose, Donald J; Egol, Kenneth

    2009-06-01

    Treatment of tibial stress fractures in elite dancers is centered on rest and activity modification. Surgical intervention in refractory cases has important implications affecting the dancers' careers. Refractory tibial stress fractures in dancers can be treated successfully with drilling and bone grafting or intramedullary nailing. Case series; Level of evidence, 4. Between 1992 and 2006, 1757 dancers were evaluated at a dance medicine clinic; 24 dancers (1.4%) had 31 tibial stress fractures. Of that subset, 7 (29.2%) elite dancers with 8 tibial stress fractures were treated operatively with either intramedullary nailing or drilling and bone grafting. Six of the patients were followed up closely until they were able to return to dance. One patient was available only for follow-up phone interview. Data concerning their preoperative treatment regimens, operative procedures, clinical union, radiographic union, and time until return to dance were recorded and analyzed. The mean age of the surgical patients at the time of stress fracture was 22.6 years. The mean duration of preoperative symptoms before surgical intervention was 25.8 months. Four of the dancers were male and 3 were female. All had failed nonoperative treatment regimens. Five patients (5 tibias) underwent drilling and bone grafting of the lesion, and 2 patients (3 tibias) with completed fractures or multiple refractory stress fractures underwent intramedullary nailing. Clinical union was achieved at a mean of 6 weeks and radiographic union at 5.1 months. Return to full dance activity was at an average of 6.5 months postoperatively. Surgical intervention for tibial stress fractures in dancers who have not responded to nonoperative management allowed for resolution of symptoms and return to dancing with minimal morbidity.

  4. Intraoperative mapping of expressive language cortex using passive real-time electrocorticography

    Directory of Open Access Journals (Sweden)

    AmiLyn M. Taplin

    2016-01-01

    Full Text Available In this case report, we investigated the utility and practicality of passive intraoperative functional mapping of expressive language cortex using high-resolution electrocorticography (ECoG. The patient presented here experienced new-onset seizures caused by a medium-grade tumor in very close proximity to expressive language regions. In preparation of tumor resection, the patient underwent multiple functional language mapping procedures. We examined the relationship of results obtained with intraoperative high-resolution ECoG, extraoperative ECoG utilizing a conventional subdural grid, extraoperative electrical cortical stimulation (ECS mapping, and functional magnetic resonance imaging (fMRI. Our results demonstrate that intraoperative mapping using high-resolution ECoG is feasible and, within minutes, produces results that are qualitatively concordant to those achieved by extraoperative mapping modalities. They also suggest that functional language mapping of expressive language areas with ECoG may prove useful in many intraoperative conditions given its time efficiency and safety. Finally, they demonstrate that integration of results from multiple functional mapping techniques, both intraoperative and extraoperative, may serve to improve the confidence in or precision of functional localization when pathology encroaches upon eloquent language cortex.

  5. The utility of intraoperative ultrasound in modified radical neck dissection: a pilot study.

    Science.gov (United States)

    Agcaoglu, Orhan; Aliyev, Shamil; Taskin, Halit Eren; Aksoy, Erol; Siperstein, Allan; Berber, Eren

    2014-04-01

    Although the value of surgeon-performed neck ultrasound (SPUS) for thyroid nodules has been validated, the utility of intraoperative ultrasound (US) in modified radical neck dissection (MRND) has not been reported in the literature. The aim of this study was to analyze the utility of intraoperative SPUS in assessing the completeness of MRND for thyroid cancer. Between 2007 and 2011, a total of 25 patients underwent MRND by 1 surgeon for thyroid cancer. All patients underwent intraoperative SPUS, which was repeated at the end of the neck dissection (completion US) to look for missed lymph nodes (LNs). There were 10 male and 15 female patients. Pathology included 23 papillary and 2 medullary carcinomas. The number of LNs removed per case was 23 ± 2, and the number of positive was LNs 5 ± 1. In 4 (16%) cases, intraoperative US detected 7 residual LNs, which would have been missed, if completion US were not done. These missed LNs were located in low-level IV (3 nodes), high-level II (2 nodes), and posterior level V (2 nodes) and measured 1.4 ± 0.2 cm. At follow-up, recurrence was seen in 2 (8%) patients, including a superior mediastinal recurrence in a patient with tall cell cancer and a jugular LN recurrence at level II in another patient with papillary thyroid cancer. This pilot study shows that intraoperative SPUS can help assess the completeness of MRND. According to our results, intraoperative completion US identifies LNs missed by palpation 16% of the time.

  6. Malunited fracture of the body and condyle of the mandible : A Case Report.

    Science.gov (United States)

    Yeluri, Ramakrishna; Baliga, Sudhindra; Munshi, Autar Krishen

    2010-07-01

    Mandibular fractures are the most common facial fractures seen in hospitalized children and their incidence increases with age. Treatment options include soft diet, intermaxillary fixation with eyelet wires, arch bars, circummandibular wiring, or stents. Alternative options include open reduction and internal fixation through either an intraoral or extraoral approach. Many factors complicate the management of pediatric mixed-dentition mandibular fractures: tooth eruption, short roots, developing tooth buds and growth issues. One major factor is the inherent instability of the occlusion in the mixed deciduous-permanent tooth phase. This case report documents a child in mixed dentition period with a complication arising due to direct fixation of the fractured mandible.

  7. Computed tomograms of blowout fracture

    International Nuclear Information System (INIS)

    Ito, Haruhide; Hayashi, Minoru; Shoin, Katsuo; Hwang, Wen-Zern; Yamamoto, Shinjiro; Yonemura, Taizo.

    1985-01-01

    We studied 18 cases of orbital fractures, excluding optic canal fracture. There were 11 cases of pure blowout fracture and 3 of the impure type. The other 4 cases were orbital fractures without blowout fracture. The cardinal syndromes were diplopia, enophthalmos, and sensory disturbances of the trigeminal nerve in the pure type of blowout fracture. Many cases of the impure type of blowout fracture or of orbital fracture showed black eyes or a swelling of the eyelids which masked enophthalmos. Axial and coronal CT scans demonstrated: 1) the orbital fracture, 2) the degree of enophthalmos, 3) intraorbital soft tissue, such as incarcerated or prolapsed ocular muscles, 4) intraorbital hemorrhage, 5) the anatomical relation of the orbital fracture to the lacrimal canal, the trochlea, and the trigeminal nerve, and 6) the lesions of the paranasal sinus and the intracranial cavity. CT scans play an important role in determining what surgical procedures might best be employed. Pure blowout fractures were classified by CT scans into these four types: 1) incarcerating linear fracture, 2) trapdoor fracture, 3) punched-out fracture, and 4) broad fracture. Cases with severe head injury should be examined to see whether or not blowout fracture is present. If the patients are to hope to return to society, a blowout fracture should be treated as soon as possible. (author)

  8. Computed tomograms of blowout fracture

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Haruhide; Hayashi, Minoru; Shoin, Katsuo; Hwang, Wen-Zern; Yamamoto, Shinjiro; Yonemura, Taizo

    1985-02-01

    We studied 18 cases of orbital fractures, excluding optic canal fracture. There were 11 cases of pure blowout fracture and 3 of the impure type. The other 4 cases were orbital fractures without blowout fracture. The cardinal syndromes were diplopia, enophthalmos, and sensory disturbances of the trigeminal nerve in the pure type of blowout fracture. Many cases of the impure type of blowout fracture or of orbital fracture showed black eyes or a swelling of the eyelids which masked enophthalmos. Axial and coronal CT scans demonstrated: 1) the orbital fracture, 2) the degree of enophthalmos, 3) intraorbital soft tissue, such as incarcerated or prolapsed ocular muscles, 4) intraorbital hemorrhage, 5) the anatomical relation of the orbital fracture to the lacrimal canal, the trochlea, and the trigeminal nerve, and 6) the lesions of the paranasal sinus and the intracranial cavity. CT scans play an important role in determining what surgical procedures might best be employed. Pure blowout fractures were classified by CT scans into these four types: 1) incarcerating linear fracture, 2) trapdoor fracture, 3) punched-out fracture, and 4) broad fracture. Cases with severe head injury should be examined to see whether or not blowout fracture is present. If the patients are to hope to return to society, a blowout fracture should be treated as soon as possible. (author).

  9. Flank pseudohernia following posterior rib fracture: a case report.

    Science.gov (United States)

    Butensky, Adam M; Gruss, Leah P; Gleit, Zachary L

    2016-10-01

    A pseudohernia is an abdominal wall bulge that may be mistaken for a hernia but that lacks the disruption of the abdominal wall that characterizes a hernia. Thus, the natural history and treatment of this condition differ from those of a hernia. This is the first report of a pseudohernia due to cough-associated rib fracture. A case of pseudohernia due to fractures of the 10 th and 11 th ribs in a 68-year-old white woman is presented. The patient suffered from a major coughing episode 1 year prior to her presentation, after which she noted a progressively enlarging bulge in her left flank. Computed tomography demonstrated a bulge in the abdominal wall containing bowel and spleen but with all muscle and fascial layers intact; in addition, lateral 10 th rib and posterior 11 th rib fractures were noted. As there was no defect in muscle or fascia, we diagnosed a pseudohernia, likely due to a denervation injury from the fractured ribs. Symptomatic treatment was recommended, including wearing a corset and referral to a pain management clinic. Symptomatic treatment is thought to be the mainstay of therapy for pseudohernias, as surgical intervention is unlikely to be of benefit.

  10. Hip fracture fixation in a patient with below-knee amputation presents a surgical dilemma: a case report

    Directory of Open Access Journals (Sweden)

    Rethnam Ulfin

    2008-09-01

    Full Text Available Abstract Introduction Hip fracture fixation surgery in patients with below-knee amputations poses a challenging problem to the surgeon in terms of obtaining traction for reduction of the fracture. The absence of the foot and part of the leg in these patients makes positioning on the fracture table difficult. We highlight this difficult problem and suggest techniques to overcome it. Case presentation A 73-year-old man with bilateral below-knee amputations presented with a history of fall. Radiographs revealed an inter-trochanteric fracture of the femur. A dynamic hip screw fixation was planned for the fracture but the dilemma was on how to position the patient on the fracture table for the surgery. Special attention was needed in positioning the patient and in surgical fixation of the fracture. Conclusion Hip fracture fixation in patients with below-knee amputations poses a special problem in positioning for fracture reduction and fixation. In this case report, we share our experience and suggest techniques to use when encountering this difficult problem.

  11. Management of nonunion after an old - neglected ankle fracture in diabetic patient; case report

    Directory of Open Access Journals (Sweden)

    Tudor M. Gavrilă

    2016-11-01

    Full Text Available Ankle fractures represent 9% of fractures. Even if it is a relatively usual fracture, the presence of diabetes makes treatment more difficult and rate of complications is higher than in the rest of population. The incidence of ankle fractures increased in the last half century. Many studies from SUA, England, Sweden and Finland suggest that the epidemiology of ankle fractures continues to change as populations age, up to the age 60 of years in men and above age of 50 years in women. Two-thirds of fractures are isolated malleolar fractures, bimalleolar fractures occur in one-fourth of patients and trimaleolar fractures occur in the rest of them. We present a case of 60 years old women with non-insulin dependent diabetes for 22 years who sustained a fracture of ankle. Her first presentation at doctor was after 4 months after injury and surgical treatment occurred after 8 months after the injury. She was operated using an external fixator. Despite the fact the treatment was delayed, the evolution of lesion was good and patient could regained normal gate.

  12. Periprosthetic fractures in the resurfaced hip--A case report and review of the literature.

    LENUS (Irish Health Repository)

    Brennan, Stephen A

    2013-02-01

    Traumatic periprosthetic fractures adjacent a hip resurfacing prosthesis are rare. When proximal fractures are encountered the obvious surgical solution is to revise to a large head stemmed femoral component. A previously well functioning implant may however be retained as various non-operative and operative treatment options exist. This paper reports the case history of a traumatic periprosthetic fracture successfully treated with cannulated screw fixation and reviews the current literature.

  13. Newer techniques for intravascular and intraoperative neurointerventional procedures

    International Nuclear Information System (INIS)

    Higashida, R.T.; Halbach, V.V.; Hieshima, G.B.; Yang, P.

    1987-01-01

    A videotape demonstrating newer techniques used in intravascular and intraoperative embolization procedures will be presented. The authors discuss the use of some of the newer embolic agents, real-time digital subtraction angiography, roadmapping techniques, and the use of microcatheters and steerable micro guide wires, which has greatly facilitated neurovascullar embolization procedures and enhanced patient safety. A number of actual intraoperative and intravascular cases will be shown demonstrating treatment of vascular malformations of the brain and spinal cord, carotid cavernous sinus fistulas, aneurysms and dural arteriovenous malformations. The indications for treatment, patient selection, technical preparation and newer methodologies and approaches to complex vascular lesions of the brain and spinal cord are discussed in detail

  14. The value of intraoperative ultrasound (IUS) examination for the visualization of metastatic cerebral lesions, compared with computed tomography (CT) and magnetic resonance (MRI)

    International Nuclear Information System (INIS)

    Tacikowska, M.; Szczerbicki, M.; Grzesiakowska, U.

    2001-01-01

    The purpose of this study is: 1. to assess the value of intraoperative ultrasonographic examination (IUSG) in confirming intraoperatively the presence of metastatic tumours detected preoperatively by computed tomography (CT) and magnetic resonance tomography (MRI), 2. to evaluate an accordance of the numbers, localization and dimensions of metastatic tumours recognized preoperatively (CT and MRI) with those shown by intraoperative USG, 3. to comparatively assess the images of metastatic tumours found in preoperative CT and MRI examinations and in intraoperative USG examinations. Sixteen patients were operated upon for metastatic intracranial tumours from various primary foci. All patients had diagnostic brain examinations before the operation: MRI and CT in 7 cases, only MRI in 3 cases, only CT in 6 cases. Intraoperative USG examination was done in all cases. Retrospective analysis included: 1. comparative assessment of the images of metastatic tumours in intraoperative USG versus preoperative MRI and CT findings, 2. analysis of the number, localization and dimensions of metastatic tumours detected preoperatively and in intraoperative USG examination. The comparison of the greatest dimensions of metastatic lesions measured in CT and MRI findings, and in intraoperative USG based on Student t test showed no statistically significant differences between the examinations performed, p=0.2449. No statistically significant difference were found either between the numbers of metastatic lesions detected by these methods, p=0.71830. In the analysis of the images of metastatic lesions in preoperative examinations, the non--homogenous foci with margin enhancement after administration of gadolinium or contrast medium, with inner area not enhanced (necrosis?) were found in 8 cases (10 foci lesions), and in USG in 6 cases (9 focal lesions). In one case (one lesion) USG showed that the tumour was hypo echogenic as a whole, without areola around it. Intraoperative USG examination

  15. Diagnosis and treatment of talar dislocation fractures illustrated by 3 case reports and review of literature

    NARCIS (Netherlands)

    Haverkort, J. J M; Leenen, L. P H; van Wessem, K. J. P.

    2015-01-01

    Introduction Talar fractures are a rare type of fractures (less than 1%). They are difficult to treat and outcome is often complicated by arthritis and avascular necrosis. In this article three cases are presented with different types of dislocated talar neck fractures. Anatomy of the talus,

  16. Ankle Fracture Surgery on a Pregnant Patient Complicated by Intraoperative Emergency Caesarian Section

    Directory of Open Access Journals (Sweden)

    Ran Schwarzkopf

    2013-01-01

    Full Text Available We report the case of a woman in the third trimester of pregnancy who sustained an ankle fracture dislocation that could not be adequately closed reduced. After discussions with the patient, her obstetrician, and the anesthesiologists, she was indicated for surgical fixation. A heart tone monitor was used to assess fetal health during the procedure. During surgical incision, the fetus went into distress, and an emergency caesarian section was performed. After delivery of the infant and abdominal closer, surgery was completed. Due to a cohesive team effort, both the patient and her infant had excellent outcomes. There are many important considerations in the surgical management of the pregnant patient with traumatic orthopaedic injuries. Of especial importance to the orthopaedic surgeon is the impact of patient positioning on uteroplacental blood flow. This report discusses factors that should be taken into account by any orthopaedist who plans to operate on a pregnant patient.

  17. Fixed-angle plates in patella fractures - a pilot cadaver study

    Directory of Open Access Journals (Sweden)

    Wild M

    2011-01-01

    Full Text Available Abstract Objective Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella. Methods In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge, quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made. Results Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65. Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed. Conclusions Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays

  18. Application of 3D Printing in the Surgical Planning of Trimalleolar Fracture and Doctor-Patient Communication

    Directory of Open Access Journals (Sweden)

    Long Yang

    2016-01-01

    Full Text Available To evaluate the effect of 3D printing in treating trimalleolar fractures and its roles in physician-patient communication, thirty patients with trimalleolar fractures were randomly divided into the 3D printing assisted-design operation group (Group A and the no-3D printing assisted-design group (Group B. In Group A, 3D printing was used by the surgeons to produce a prototype of the actual fracture to guide the surgical treatment. All patients underwent open reduction and internal fixation. A questionnaire was designed for doctors and patients to verify the verisimilitude and effectiveness of the 3D-printed prototype. Meanwhile, the operation time and the intraoperative blood loss were compared between the two groups. The fracture prototypes were accurately printed, and the average overall score of the verisimilitude and effectiveness of the 3D-printed prototypes was relatively high. Both the operation time and the intraoperative blood loss in Group A were less than those in Group B (P<0.05. Patient satisfaction using the 3D-printed prototype and the communication score were 9.3±0.6 points. A 3D-printed prototype can faithfully reflect the anatomy of the fracture site; it can effectively help the doctors plan the operation and represent an effective tool for physician-patient communication.

  19. A clay-shoveler's fracture with renal transplantation and osteoporosis: a case report

    Directory of Open Access Journals (Sweden)

    Unay Koray

    2008-06-01

    Full Text Available Abstract Introduction Clay-shoveler's fracture is a rare cervicodorsal spinous process fracture and there is little information regarding the prognosis of patients with this condition in conjunction with osteoporosis and corticosteroid use. Case presentation A 39-year-old man was admitted to our institution with a 6-month history of cervicodorsal pain prior to admission. The patient had previously undergone renal transplantation and was on corticosteroids, and had developed osteoporosis. We treated him with a cervical collar, non-steroidal anti-inflammatory agents and alendronate. The patient was advised against performing weight-bearing activities for 6 months. Conclusion Clay-shoveler's fracture with osteoporosis and corticosteroid use presented by fracture of the cervicodorsal aspect of the spinous processes may be successfully treated with a collar, alendronate and long-term rest.

  20. Monitoring Induced Fractures with Electrical Measurements using Depth to Surface Resistivity: A Field Case Study

    Science.gov (United States)

    Wilt, M.; Nieuwenhuis, G.; Sun, S.; MacLennan, K.

    2016-12-01

    Electrical methods offer an attractive option to map induced fractures because the recovered anomaly is related to the electrical conductivity of the injected fluid in the open (propped) section of the fracture operation. This is complementary to existing micro-seismic technology, which maps the mechanical effects of the fracturing. In this paper we describe a 2014 field case where a combination of a borehole casing electrode and a surface receiver array was used to monitor hydrofracture fracture creation and growth in an unconventional oil field project. The fracture treatment well was 1 km long and drilled to a depth of 2.2 km. Twelve fracture events were induced in 30 m intervals (stages) in the 1 km well. Within each stage 5 events (clusters) were initiated at 30 m intervals. Several of the fracture stages used a high salinity brine, instead of fresh water, to enhance the electrical signal. The electrical experiment deployed a downhole source in a well parallel to the treatment well and 100 m away. The source consisted of an electrode attached to a wireline cable into which a 0.25 Hz square wave was injected. A 60-station electrical field receiver array was placed above the fracture and extending for several km. Receivers were oriented to measure electrical field parallel with the presumed fracture direction and those perpendicular to it. Active source electrical data were collected continuously during 7 frac stages, 3 of which used brine as the frac fluid over a period of several days. Although the site was quite noisy and the electrical anomaly small we managed to extract a clear frac anomaly using field separation, extensive signal averaging and background noise rejection techniques. Preliminary 3D modeling, where we account for current distribution of the casing electrode and explicitly model multiple thin conductive sheets to represent fracture stages, produces a model consistent with the field measurements and also highlights the sensitivity of the

  1. Fracturing of revision of a cobalt-chrome femoral head after fracturing of a ceramic femoral head, with diffuse metallosis. Case report

    Directory of Open Access Journals (Sweden)

    Pedro Miguel Dantas Costa Marques

    2013-04-01

    Full Text Available We presente a case of a fracture of a cobalt-chrome femoral head after revision of a hip total prosthesis with ceramic femoral head fracture. During surgery we found the cobalt-chrome femoral head fracture, wear of the polyethylene and massive metallosis in muscular and cartilaginous tissue. Both femoral stem and acetabular cup were stable and without apparent wearing. After surgical debridement, we promoted the substitution of the femoral head and the acetabular polyethylene by similar ones. After 12 months of follow-up, the patient has no pain complaints, function limit or systemic signs associated with malign metallosis

  2. Percutaneous pedicle screw for unstable spine fractures in polytraumatized patients: A report of two cases

    Directory of Open Access Journals (Sweden)

    Boon Beng Tan

    2012-01-01

    Full Text Available Unstable spine fractures commonly occur in the setting of a polytraumatized patient. The aim of management is to balance the need for early operative stabilization and prevent additional trauma due to the surgery. Recent published literature has demonstrated the benefits of early stabilization of an unstable spine fracture particularly in patients with higher injury severity score (ISS. We report two cases of polytrauma with unstable spine fractures stabilized with a minimally invasive percutaneous pedicle screw instrumentation system as a form of damage control surgery. The patients had good recovery from the polytrauma injuries. These two cases illustrate the role of minimally invasive stabilization, its limitations and technical pitfalls in the management of unstable spine fractures in the polytrauma setting as a form of damage control surgery.

  3. Bilateral stress fracture of femoral neck in non-athlete - case report

    Directory of Open Access Journals (Sweden)

    Ubiratan Stefani de Oliveira

    Full Text Available ABSTRACT Bilateral stress fracture of femoral neck in healthy young patients is an extremely rare entity, whose diagnostic and treatment represent a major challenge. Patients with history of hip pain, even non-athletes or military recruits, should be analyzed to achieve an early diagnosis and prevent possible complications from the surgical treatment. This report describes a 43-year-old male patient, non-athlete, without previous diseases, who developed bilateral stress fracture of femoral neck without displacement. He had a late diagnosis; bilateral osteosynthesis was made using cannulated screws. Although the diagnosis was delayed in this case, the study highlights the importance of the diagnosis of stress fracture, regardless of the activity level of the patients, for the success of the treatment.

  4. Intraoperative Deaths at Ahmadu Bello University Teaching Hospital ...

    African Journals Online (AJOL)

    Nine cases of intraoperative deaths were recorded. Most of the deaths occurred among the gravely ill, inadequately prepared patients and patients whose operations were done in the late hours of the night. Conclusion: This tragedy is preventable by paying meticulous attention to details and careful patient selection and ...

  5. Intra-Operative Indocyanine Green-Videoangiography (ICG-VA) in ...

    African Journals Online (AJOL)

    Methods: Fifteen consecutive patients with anterior circulation aneurysms who underwent craniotomy and clipping of the aneurysms were included in this study. Intraoperative ICG-VA was performed in all cases after exposure of the aneurysm and the branches in the vicinity of the aneurysm or the parent vessel before ...

  6. 3D printing-based minimally invasive cannulated screw treatment of unstable pelvic fracture.

    Science.gov (United States)

    Cai, Leyi; Zhang, Yingying; Chen, Chunhui; Lou, Yiting; Guo, Xiaoshan; Wang, Jianshun

    2018-04-04

    Open reduction and internal fixation of pelvic fractures could restore the stability of the pelvic ring, but there were several problems. Minimally invasive closed reduction cannulated screw treatment of pelvic fractures has lots advantages. However, how to insert the cannulated screw safely and effectively to achieve a reliable fixation were still hard for orthopedist. Our aim was to explore the significance of 3D printing technology as a new method for minimally invasive cannulated screw treatment of unstable pelvic fracture. One hundred thirty-seven patients with unstable pelvic fractures from 2014 to 2016 were retrospectively analyzed. Based on the usage of 3D printing technology for preoperative simulation surgery, they were assigned to 3D printing group (n = 65) and control group (n = 72), respectively. These two groups were assessed in terms of operative time, intraoperative fluoroscopy, postoperative reduction effect, fracture healing time, and follow-up function. The effect of 3D printing technology was evaluated through minimally invasive cannulated screw treatment. There was no significant difference in these two groups with respect to general conditions, such as age, gender, fracture type, time from injury to operation, injury cause, and combined injury. Length of surgery and average number of fluoroscopies were statistically different for 3D printing group and the control group (p 3D printing group, versus 22/72 cases (30.6%) scored as excellent and 36/72 cases (50%) as good for the control group. On the other hand, using the Majeed functional scoring criteria, there were 27/65 (41.5%) excellent and 26/65 (40%) good cases for the 3D printing group in comparison to 30/72 (41.7%) and 28/72 (38.9%) cases for the control group, respectively. This suggests no significant difference between these two groups about the function outcomes. Full reduction and proper fixation of the pelvic ring and reconstruction of anatomical morphology are of great

  7. Total Hip Intraoperative Femur Fracture: Do the Design Enhancements of a Second-Generation Tapered-Wedge Stem Reduce the Incidence?

    Science.gov (United States)

    Colacchio, Nicholas D; Robbins, Claire E; Aghazadeh, Mehran S; Talmo, Carl T; Bono, James V

    2017-10-01

    Intraoperative femur fracture (IFF) is a well-known complication in primary uncemented total hip arthroplasty (THA). Variations in implant instrumentation design and operative technique may influence the risk of IFF. This study investigates IFF between a standard uncemented tapered-wedge femoral stem and its second-generation successor with the following design changes: size-specific medial curvature, proportional incremental stem growth, modest reduction in stem length, and distal lateral relief. A single experienced surgeon's patient database was retrospectively queried for IFF occurring during primary uncemented THA using a standard tapered-wedge femoral stem system or a second-generation stem. All procedures were performed using soft tissue preserving anatomic capsule repair and posterior approach. The primary outcome measure was IFF. A z-test of proportions was performed to determine significant difference between the 2 stems with respect to IFF. Patient demographics, Dorr classification, and implant characteristics were also examined. Forty-one of 1510 patients (2.72%) who received a standard tapered-wedge femoral stem sustained an IFF, whereas 5 of 800 patients (0.63%) using the second-generation stem incurred an IFF. No other significant associations were found. A standard tapered-wedge femoral stem instrumentation system resulted in greater than 4 times higher incidence of IFF than its second-generation successor used for primary uncemented THA. Identifying risk factors for IFF is necessary to facilitate implant system improvements and thus maximize patient outcomes. Copyright © 2017. Published by Elsevier Inc.

  8. Malunited fracture of the body and condyle of the mandible : A Case Report

    Directory of Open Access Journals (Sweden)

    Ramakrishna Yeluri

    2010-01-01

    Full Text Available Mandibular fractures are the most common facial fractures seen in hospitalized children and their incidence increases with age. Treatment options include soft diet, intermaxillary fixation with eyelet wires, arch bars, circummandibular wiring, or stents. Alternative options include open reduction and internal fixation through either an intraoral or extraoral approach. Many factors complicate the management of pediatric mixed-dentition mandibular fractures: tooth eruption, short roots, developing tooth buds and growth issues. One major factor is the inherent instability of the occlusion in the mixed deciduous-permanent tooth phase. This case report documents a child in mixed dentition period with a complication arising due to direct fixation of the fractured mandible.

  9. Intraoperative hyperventilation vs remifentanil during electrocorticography for epilepsy surgery - a case report

    DEFF Research Database (Denmark)

    Kjaer, Troels W; Madsen, F F; Moltke, F B

    2010-01-01

    BACKGROUND: Traditionally, intraoperative intracranial electroen-cephalography-recordings are limited to the detection of the irritative zone defined by interictal spikes. However, seizure patterns revealing the seizure onset zone are thought to give better localizing information, but are impract...

  10. Ostosintesis of low profile in the treatment of the fractures of the tibial pylon

    International Nuclear Information System (INIS)

    Agudelo R, Juan Fernando; Kalb H, Juan Pedro

    2001-01-01

    The preliminary results are presented, among January 1999 - September 2000, in the General Hospital of Medellin - Clinica Leon XIII. Eight cases were revised of patient with intraarticular fractures of the tibial pylon, treaties with open reduction and osteosintesis of low profile following the modified protocol of Ruedi-Allgower, with the objective of describing the quality of the reduction and the postoperative complications. The data were obtained of the clinical history and personal interview with the patients. The time of pursuit average was of 5,2 months. Of the eight fractures, seven (87.5%) they were consequence of accidents of traffic and one for firearm projectile. Two fractures were presented type I (25%), three type II (37.5%) and three type III (37.5%), according to the classification of Ruedi-Allgower. The surgery was carries out on the average to the 13.4 days. In all the cases it uses traction transcalcanea intraoperative; six patients required osteosintesis of the fibula: The plaques of low profile in tibia were modeled to the anterolateral surface to diminish the medial desperiostization. In six cases the quality of the radiological reduction was good according to the approaches of Burwell and Charnley in one to regulate and in one bad. In all the cases it begins passive and active rehabilitation after the first week and the support was restricted by three months. In two cases superficial dehiscence of the surgical wound those were presented, which they evolved satisfactorily, and a case of asintomatic no union has not required reintervention. The results suggest that the osteosintesis of low profile is a sure method of treatment of these lesions if it is carried out when the conditions of soft tissues are good and the medial desperiostization is limited

  11. Visualizing Macular Structures During Membrane Peeling Surgery With an Intraoperative Spectral-Domain Optical Coherence Tomography Device.

    Science.gov (United States)

    Leisser, Christoph; Hackl, Christoph; Hirnschall, Nino; Luft, Nikolaus; Döller, Birgit; Draschl, Petra; Rigal, Karl; Findl, Oliver

    2016-04-01

    The aim of this study was to examine the quality of intraoperative visualization of the posterior hyaloid, epiretinal membrane (ERM), inner limiting membrane (ILM), and hyporeflective subfoveal zone with a commercially available, microscope-integrated spectral-domain OCT setup (mi-SD-OCT) (Rescan 700; Carl Zeiss Meditec AG, Germany). Twenty patients prospectively scheduled for pars plana vitrectomy with membrane peeling due to an idiopathic ERM were included. Standard 23-gauge, three-port pars plana vitrectomy with membrane peeling and staining of the ERM with a trypan blue-based chromovitrectomy dye was performed in all cases. Intraoperative SD-OCT was performed before and after peeling and visualization of the posterior hyaloid, ERM, ILM, and presence of subfoveal hyporeflective zones were examined. OCT follow-ups were performed 2 days and 3 months after surgery. The study was approved by the local ethics committee of the city of Vienna. Successful intraoperative visualization of ERM by mi-SD-OCT was possible in all cases. The posterior hyaloid and ILM could not be seen in the mi-SD-OCT scans, whereas an intraoperative subfoveal hyporeflective zone presented in 35% of cases. In 12.5% an independent subfoveal hyporeflective zone presented postoperatively. Visual acuity improved in 93.8% of patients after surgery. mi-SD-OCT appears to be a valuable tool for intraoperative visualization of the ERM and offers immediate visualization of retinal anatomy during peeling. Therefore, it adds to the understanding of intraoperative traumatic changes due to the peeling procedure. Copyright 2016, SLACK Incorporated.

  12. Application of Intraoperative Ultrasonography for Guiding Microneurosurgical Resection of Small Subcortical Lesions

    International Nuclear Information System (INIS)

    Wang, Jia; Duan, Yun You; Liu, Xi; Wang, Yu; Gao, Guo Dong; Qin, Huai Zhou; Wang, Liang

    2011-01-01

    We wanted to evaluate the clinical value of intraoperative ultrasonography for real-time guidance when performing microneurosurgical resection of small subcortical lesions. Fifty-two patients with small subcortical lesions were involved in this study. The pathological diagnoses were cavernous hemangioma in 25 cases, cerebral glioma in eight cases, abscess in eight cases, small inflammatory lesion in five cases, brain parasite infection in four cases and the presence of an intracranial foreign body in two cases. An ultrasonic probe was sterilized and lightly placed on the surface of the brain during the operation. The location, extent, characteristics and adjacent tissue of the lesion were observed by high frequency ultrasonography during the operation. All the lesions were located in the cortex and their mean size was 1.3 ± 0.2 cm. Intraoperative ultrasonography accurately located all the small subcortical lesions, and so the neurosurgeon could provide appropriate treatment. Different lesion pathologies presented with different ultrasonic appearances. Cavernous hemangioma exhibited irregular shapes with distinct margins and it was mildly hyperechoic or hyperechoic. The majority of the cerebral gliomas displayed irregular shapes with indistinct margins, and they often showed cystic and solid mixed echoes. Postoperative imaging identified that the lesions had completely disappeared, and the original symptoms of all the patients were significantly alleviated. Intraoperative ultrasonography can help accurately locate small subcortical lesions and it is helpful for selecting the proper approach and guiding thorough resection of these lesions.

  13. Application of Intraoperative Ultrasonography for Guiding Microneurosurgical Resection of Small Subcortical Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Duan, Yun You; Liu, Xi; Wang, Yu; Gao, Guo Dong; Qin, Huai Zhou; Wang, Liang [Tangdu Hospital of the Fourth Military Medicine University, Xi an (China)

    2011-10-15

    We wanted to evaluate the clinical value of intraoperative ultrasonography for real-time guidance when performing microneurosurgical resection of small subcortical lesions. Fifty-two patients with small subcortical lesions were involved in this study. The pathological diagnoses were cavernous hemangioma in 25 cases, cerebral glioma in eight cases, abscess in eight cases, small inflammatory lesion in five cases, brain parasite infection in four cases and the presence of an intracranial foreign body in two cases. An ultrasonic probe was sterilized and lightly placed on the surface of the brain during the operation. The location, extent, characteristics and adjacent tissue of the lesion were observed by high frequency ultrasonography during the operation. All the lesions were located in the cortex and their mean size was 1.3 {+-} 0.2 cm. Intraoperative ultrasonography accurately located all the small subcortical lesions, and so the neurosurgeon could provide appropriate treatment. Different lesion pathologies presented with different ultrasonic appearances. Cavernous hemangioma exhibited irregular shapes with distinct margins and it was mildly hyperechoic or hyperechoic. The majority of the cerebral gliomas displayed irregular shapes with indistinct margins, and they often showed cystic and solid mixed echoes. Postoperative imaging identified that the lesions had completely disappeared, and the original symptoms of all the patients were significantly alleviated. Intraoperative ultrasonography can help accurately locate small subcortical lesions and it is helpful for selecting the proper approach and guiding thorough resection of these lesions.

  14. A unique case of nontraumatic femoral neck fracture following epilepsia partialis continua

    Directory of Open Access Journals (Sweden)

    Karl O. Nakken

    2015-01-01

    Full Text Available People with epilepsy are more accident prone than the non-epilepsy population. Bone fractures are most often due to seizure-related falls. However, seizures themselves, in particular generalized tonic-clonic seizures, may also cause fractures, e.g. of the thoracic spine. Here, I present a man who developed focal epilepsy following a subarachnoidal hemorrhage. During a focal motor seizure with left-sided convulsions and preserved consciousness that lasted 2 hrs, he sustained a femoral neck fracture. In persons with low mineral density, as in this case, contractions associated with simple focal motor seizures may be sufficient to give rise to such a severe complication.

  15. Birth-related mid-posterior rib fractures in neonates: a report of three cases (and a possible fourth case) and a review of the literature

    NARCIS (Netherlands)

    van Rijn, Rick R.; Bilo, Rob A. C.; Robben, Simon G. F.

    2009-01-01

    BACKGROUND: Posterior rib fractures in young children have a high positive predictive value for non-accidental injury (NAI). Combined data of five studies on birth trauma (115,756 live births) showed no cases of rib fractures resulting from birth trauma. There have, however, been sporadic cases

  16. Single-stage intraoperative transhepatic biliary stenting in patients with unresectable hepatobiliary pancreatic tumors.

    Science.gov (United States)

    Iwasaki, Yoshimi; Kubota, Keiichi; Kita, Junji; Katoh, Masato; Shimoda, Mitsugi; Sawada, Tokihiko; Iso, Yukihiro

    2013-02-01

    The current study was conducted to evaluate the safety and utility of intraoperative transhepatic biliary stenting (ITBS) in patients with unresectable malignant biliary obstruction (UMBO) diagnosed intraoperatively. In this study, 50 patients who underwent ITBS for UMBO between April 2001 and May 2009 were retrospectively reviewed. For 26 patients who underwent preoperative percutaneous transhepatic biliary drainage (PTBD), the expandable metallic stent (EMS) was inserted intraoperatively by the PTBD route in a single stage. For 24 patients, the intrahepatic bile ducts were intentionally dilated by injection of saline via the endoscopic nasobiliary drainage or the percutaneous transhepatic gallbladder drainage route, and the puncture was performed under intraoperative ultrasound guidance followed by guidewire and catheter insertion. Thereafter, the EMS was placed in the same manner. The initial postoperative complications and long-term results of ITBS were evaluated. In all cases, ITBS was technically successful. Stenting alone was performed in 22 patients and stenting combined with other procedures in 28 patients. Hospital mortality occurred for three patients (6 %), and complication-related mortality occurred in two cases (4 %). There were nine cases (18 %) of postoperative complications. The median survival time was 179 days, and the EMS patency time was 137 days. During the follow-up period, EMS occlusion occurred in 23 cases (46 %). Best supportive care was a significant independent risk factor for early mortality within 100 days after ITBS (p = 0.020, odds ratio, 9.398). Single-stage ITBS is feasible for palliation of UMBO and seems to have a low complication rate.

  17. Intraoperative Ultrasound-Guided Removal of Retained Mini Sling Anchor Causing Vaginal Pain: A Case Report.

    Science.gov (United States)

    Almassi, Nima; Goldman, Howard B

    2016-01-01

    Since the introduction of the tension-free vaginal tape, the surgical management of female stress urinary incontinence has undergone a dramatic shift toward synthetic midurethral slings (MUSs). The evolution of the MUS has led to the development of the single incision mini sling (SIMS), a minimally invasive procedure that can be performed under local anesthesia. Complications arising after SIMS placement parallel those of the traditional MUS, including pelvic pain, dyspareunia, and mesh erosion. The patient in this case presented with persistent pelvic pain due to a retained SIMS anchor after having previously undergone SIMS placement and subsequent transvaginal exploration with mesh removal. We report the use of intraoperative ultrasound for identification and removal of the retained SIMS anchor.

  18. [Case-control study on bone setting manipulation for the treatment of over degree II supination-eversion fractures of ankle joint].

    Science.gov (United States)

    Qi, Yue-Feng; Chen, Fa-Lin; Bao, Shu-Ren; Li, Cheng-Huan; Zhao, Xing-Wei; Liu, Shi-Ming; Chen, Wen-Xue; Li, Ye; Wang, Peng

    2012-08-01

    To explore therapeutic effects of bone setting manipulation for the treatment of over degree II supination-eversion fractures of ankle,and analyze manipulative reduction mechanism. From 2005 to 2008, 95 patients with over degree II supination-eversion fractures of ankle were treated respectively by manipulation and operation. There were 43 cases [11 males and 32 females with an average age of (44.95 +/- 12.65) years] in manipulation group, and 2 cases were degree II, 11 cases were degree III, and 30 cases were degree IV. There were 52 cases [21 males and 31 females with an average age of (39.96 +/- 13.28) years] in operative group,and 6 cases were degree II, 18 cases were degree III, and 28 cases were degree IV. Bone setting manipulation and hard splint external fixation were applied to manipulative group. Operative reduction internal fixation was performed in operative group. X-ray was used to evaluate reduction of fracture before and after treatment, 2 months after treatment. Ankle joint function was evaluated according to Olerud-Molander scoring system after 6 months treatment. All patients were followed up with good reduction. Three cases occurred wound complication in operative group, but not in manipulative group. In manipulation group, 19 cases got excellent results, 20 cases good and 4 cases fair; while in operative group, 30 cases got excellent results, 20 cases good and 2 cases poor. There were no significant differences in fracture reduction and ankle joint function recovery between two groups (P > 0.05). Efficacy of operative treatment was better than that of manipulative treatment at degree IV fracture (P ankle joint fractures, which has advantages of simple and safe operation, reliable efficacy. For ankle join fracture at degree IV, manipulative reduction should be adopted earlier, and operative treatment also necessary

  19. Oblique Axis Body Fracture: An Unstable Subtype of Anderson Type III Odontoid Fractures—Apropos of Two Cases

    Directory of Open Access Journals (Sweden)

    Hirokazu Takai

    2016-01-01

    Full Text Available Purpose. Anderson type III odontoid fractures have traditionally been considered stable and treated conservatively. However, unstable cases with unfavorable results following conservative treatment have been reported. Methods. We present the cases of two patients who sustained minimally displaced Anderson type III fractures with a characteristic fracture pattern that we refer to as “oblique type axis body fracture.” Results. The female patients aged 90 and 72 years, respectively, were both diagnosed with minimally displaced Anderson type III fractures. Both fractures had a characteristic “oblique type” fracture pattern. The first patient was treated conservatively with cervical spine immobilization in a semirigid collar. However, gross displacement was noted at the 6-week follow-up visit. The second patient was therefore treated operatively by C1–C3/4 posterior fusion and the course was uneventful. Conclusions. Oblique type axis body fractures resemble a highly unstable subtype of Anderson type III fractures with the potential of severe secondary deformity following conservative treatment, irrespective of initial grade of displacement. The authors therefore warrant a high index of suspicion for this injury and suggest early operative stabilization.

  20. Case report: multifocal subchondral stress fractures of the femoral heads and tibial condyles in a young military recruit.

    Science.gov (United States)

    Yoon, Pil Whan; Yoo, Jeong Joon; Yoon, Kang Sup; Kim, Hee Joong

    2012-03-01

    Subchondral stress fractures of the femoral head may be either of the insufficiency-type with poor quality bone or the fatigue-type with normal quality bone but subject to high repetitive stresses. Unlike osteonecrosis, multiple site involvement rarely has been reported for subchondral stress fractures. We describe a case of multifocal subchondral stress fractures involving femoral heads and medial tibial condyles bilaterally within 2 weeks. A 27-year-old military recruit began having left knee pain after 2 weeks of basic training, without any injury. Subsequently, right knee, right hip, and left hip pain developed sequentially within 2 weeks. The diagnosis of multifocal subchondral stress fracture was confirmed by plain radiographs and MR images. Nonoperative treatment of the subchondral stress fractures of both medial tibial condyles and the left uncollapsed femoral head resulted in resolution of symptoms. The collapsed right femoral head was treated with a fibular strut allograft to restore congruity and healed without further collapse. There has been one case report in which an insufficiency-type subchondral stress fracture of the femoral head and medial femoral condyle occurred within a 2-year interval. Because the incidence of bilateral subchondral stress fractures of the femoral head is low and multifocal involvement has not been reported, multifocal subchondral stress fractures can be confused with multifocal osteonecrosis. Our case shows that subchondral stress fractures can occur in multiple sites almost simultaneously.

  1. A new internal fixation technique for fractures of the proximal humerus--the Bilboquet device: a report on 26 cases.

    Science.gov (United States)

    Doursounian, L; Grimberg, J; Cazeau, C; Jos, E; Touzard, R C

    2000-01-01

    We describe a novel internal fixation device and report on 26 patients (mean age, 70 years) whose proximal humeral fractures were managed with this technique. The 2-part titanium implant consists of a circular staple impacted into the humeral head cancellous bone and a spigoted diaphyseal stem that inserts into the staple "cup." Of the 26 cases reviewed, 16 had 3-part fractures and 10 had 4-part fractures. Mean follow-up was 25.9 months. In the 16 3-part fractures, the mean active forward elevation was 114 degrees and the results were as follows: excellent, 7; good, 5; fair, 3; poor, 1. In the 10 4-part fracture patients, the mean active forward elevation was 101 degrees and the results were as follows: excellent, 2; good, 4; fair, 3; poor, 1. There were 5 cases of avascular necrosis and 1 case of tuberosity nonunion. Only 2 cases needed conversion to hemiarthroplasty. The new technique should simplify the surgery of these fractures and reduce the need for arthroplasty.

  2. [Conventional X-Rays of Ankle Joint Fractures in Older Patients are Not Always Predictive].

    Science.gov (United States)

    Jubel, A; Faymonville, C; Andermahr, J; Boxberg, S; Schiffer, G

    2017-02-01

    Background: Ankle fractures are extremely common in the elderly, with an incidence of up to 39 fractures per 100,000 persons per year. We found a discrepancy between intraoperative findings and preoperative X-ray findings. It was suggested that many relevant lesions of the ankle joint in the elderly cannot be detected with plain X-rays. Methods: Complete data sets and preoperative X-rays of 84 patients aged above 60 years with ankle fractures were analysed retrospectively. There were 59 women and 25 men, with a mean age of 69.9 years. Operation reports and preoperative X-rays were analysed with respect to four relevant lesions: multifragmentary fracture pattern of the lateral malleolus, involvement of the medial malleolus, posterior malleolar fractures and bony avulsion of anterior syndesmosis. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy and prevalence were calculated. Results: The prevalence of specific ankle lesions in the analyzed cohort was 24 % for the multifragmentary fracture pattern of the lateral malleolus, 38 % for fractures of the medial malleolus, 25 % for posterior malleolar fractures and 22.6 % for bony avulsions of the anterior syndesmosis. Multifragmentary fracture patterns of the lateral malleolus (sensitivity 0 %) and bony avulsions of the anterior syndesmosis (sensitivity 5 %) could not be detected in plain X-rays of the ankle joint at all. Fractures of the medial malleolus and involvement of the dorsal tibial facet were detected with a sensitivity of 96.8 % and 76.2 %, respectively, and specificity of 100 % in both cases. Conclusions: This study confirms that complex fracture patterns, such as multifragmentary involvement of the lateral malleolus, additional fracture of the medial malleolus, involvement of the dorsal tibial facet or bony avulsion of the anterior syndesmosis are common in ankle fractures of the elderly. Therefore, CT scans should be routinely considered for primary

  3. The International intraval project. Phase 1 case 2. Radionuclide migration in single natural fractures in granite

    International Nuclear Information System (INIS)

    Skagius, K.

    1992-01-01

    The INTRAVAL study addresses validation of geosphere transport models for use in repository performance assessment by examining various test cases relevant to radioactive waste disposal. This report describes the results from INTRAVAL test case 2 which is based on a set of laboratory experiments studying migration of non-sorbing as well as sorbing tracers in a single fracture in granitic cores. Three project teams have investigated this test case. Models including advection, dispersion, sorption to the fracture surface, matrix diffusion and sorption within the rock matrix were calibrated against the experimental breakthrough curves. Obtained best-fit values of the parameters determining the interaction between tracer and rock were in fair agreement with independently measured data. Models neglecting matrix diffusion and sorption within the rock matrix gave poor fits to the experimental data. These results suggest the need to include matrix diffusion and matrix sorption in the model to represent data for this test case. Furthermore, it was not possible to distinguish between hydrodynamic dispersion and channelling dispersion since equally good fits were obtained with both models. Equally good fits were also obtained with models assuming constant fracture aperture and variable fracture aperture. In the context of performance assessment of repositories in fractured rock, the major outcome from this test case is additional support for the inclusion of matrix diffusion and matrix sorption in the transport models. 17 refs., 14 figs., 3 tabs

  4. [Internal screwed plate for recent fractures of the humeral diaphysis in adults].

    Science.gov (United States)

    Dayez, J

    1999-06-01

    Can medial plating of the humerus, through an antero lateral approach, diminish incidence of iatrogenic radial palsies? We carried out a prospective study of medial plating of humeral shaft fractures through an antero lateral approach between 1988 and 1997. 41 fractures were fixed, 36 were followed up for a mean period of 5.8 years. The indications were multiple injuries (10), displaced fractures (23), and failure of conservative treatment (3). Road traffic accidents and sports injuries were the cause in 68 per cent of cases. Two fractures were open and in 9 cases there was a radial palsy. Bone graft was never used. The approach to the medial aspect of the humerus an antero lateral incision was the essential feature of the technique. After a slightly curved incision on the antero lateral aspect of the arm, the space between biceps and brachialis anterior was bluntly dissected. The assistant holded the elbow flexed in order to relax the biceps and rotated il laterally to expose the medial aspect of the bone. Splitting brachialis fibres longitudinally exposed the fracture site. It was easy to check if the radial nerve was trapped and, if not, the nerve seen during the operation. Postoperatively patients were given a simple sling and mobilised freely, including rotation. We had no intra-operative complications, no infections, no fixation failure, no post operative radial palsies and no non-unions. Results were excellent in 89 per cent of cases (full recovery of pain free range of movement). Four patient had a restriction of elbow movements of 10 degrees but without any discomfort. The mean time to union was 80 days. All radial nerve palsies recovered between 24 hours and 1 year. The plate was removed in 11 cases. Iatrogenic complications of humeral plating have led to the increased popularity of intramedullary nailing. Even if secondary radial palsies and non-unions have decreased, union of the humeral shafts is often difficult. Placing the plate into the medial

  5. Study on fracture and stress corrosion cracking behavior of casing sour service materials

    International Nuclear Information System (INIS)

    Sequera, C.; Gordon, H.

    2003-01-01

    Present work describes sulphide stress corrosion cracking and fracture toughness tests performed to high strength sour service materials of T-95, C-100 and C-110 oil well tubular grades. P-110 was considered as a reference case, since it is one of the high strength materials included in specification 5CT of American Petroleum Institute, API. Sulphide stress corrosion cracking, impact and fracture toughness values obtained in the tests show that there is a correspondence among them. A decreasing classification order was established, namely C-100, T-95, C-110 and P-110. Special grades steels studied demonstrated a better behavior in the evaluated properties than the reference case material grade: P-110. Results obtained indicate that a higher sulphide stress corrosion cracking resistance is related to a higher toughness. The fracture toughness results evidence the hydrogen influence on reducing the toughness values. (author)

  6. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    Directory of Open Access Journals (Sweden)

    Mustafa Seyhan

    2018-02-01

    Full Text Available Objectives: Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of the tibia. Patients and methods: Sixty-two patients (26 females, 36 males were included in this retrospective study. Of the removed nails, 24 were of stainless steel and 38 of titanium. Preoperative and intraoperative parameters, such as implant discomfort, anterior knee pain, operating time and amount of bleeding, and postoperative outcomes were evaluated for each patient. Results: Titanium nail group had more, but not statistically significant, intraoperative complications than stainless steel group during the removal of nails (p = .4498. Operating time and amount of intraoperative bleeding were significantly higher in titanium group than stainless steel group (p = .0306 and p < .001, respectively. Preoperative SF-36 physical component and KSS scores were significantly lower in patients who had removal of titanium nails than those of stainless steel nails, whereas there was no difference in terms of postoperative SF-36 and KSS scores. Conclusion: In conclusion, although greater bone contact with titanium increases implant stability, nail removal is more difficult, resulting in more longer surgical operation and more intraoperative bleeding. Therefore, we do not recommend titanium nail removal in asymptomatic patients. Keywords: Fractures of tibial shaft, Removal of intramedullary nailing, Stainless steel nail, Titanium nail

  7. Implant-supported rehabilitation after treatment of atrophic mandibular fractures: report of two cases.

    Science.gov (United States)

    Oliveira, Leandro Benetti de; Gabrielli, Marisa Aparecida Cabrini; Gabrielli, Mario Francisco Real; Pereira-Filho, Valfrido Antonio Pereira

    2015-12-01

    The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (fractures. Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.

  8. Probabilistic fracture mechanics applied for lbb case study: international benchmark

    International Nuclear Information System (INIS)

    Radu, V.

    2015-01-01

    An application of probabilistic fracture mechanics to evaluate the structural integrity for a case study chosen from experimental Mock-ups of FP7 STYLE project is described. The reliability model for probabilistic structural integrity, focused on the assessment of TWC in the pipe weld under complex loading (bending moment and residual stress) has been setup. The basic model is the model of fracture for through-wall cracked pipe under elastic-plastic conditions. The corresponding structural reliability approach is developed with the probabilities of failure associated with maximum load for crack initiation, net-section collapse but also the evaluation the instability loads. The probabilities of failure for a through-wall crack in a pipe subject to pure bending are evaluated by using crude Monte Carlo simulations. The results from the international benchmark are presented for the mentioned case in the context of ageing and lifetime management of pressure boundary/pressure circuit component. (authors)

  9. Intraoperative radio-frequency capacitive hyperthermia and radiation therapy for unresectable pancreatic cancer

    International Nuclear Information System (INIS)

    Nakazawa, M.; Yamashita, T.; Hashida, I.

    1988-01-01

    The authors have initiated intraoperative radiation therapy (IORT) and intraoperative radio-frequency capacitive hyperthermia (IOHT) for unresectable pancreatic cancer. After gastric (corpus) resection, IORT and IOHT were conducted and gastro-duodenostomy was performed IORT was delivered with 12 meV electron (25 Gy) and 10 MV Linac x-ray (7.5 Gy). IOHT was done with 13.56 MHz capacitive equipment aiming 43 0 C for over 30 min along with concurrent administration of 500 mg 5-FU. Five cases were heated by the conventional method and two additional cases were heated with a newly fabricated applicator. Attained temperatures monitored directly from tumor were 38.5 0 C-44.3 0 C (over 43 0 C in four cases, 40 0 C in one case, and below 40 0 C in two cass.) Pain relief was achieved in most cases. Using the new applicators, the authors could avoid unexpected hot spots and insufficient heating

  10. [Treatment of Pilon fractures complicated with fractures of fibula with titanic elastic nailing].

    Science.gov (United States)

    Liu, Yi-jun; Lin, Fu-qing; Guo, Yu-xiang

    2010-02-01

    To explore the effect of titanic elastic nailing (TEN) fixing for Pilon fractures complicated with fractures of fibula. From March 2007 to March 2009, 20 patients with Pilon fractures complicated with fractures of fibula were surgically treated with TEN. There were 14 males and 7 females with an average age of 42.6 years ranging from 35 to 70 years. Among them, 12 cases were on the left, 8 cases were on the right. All patients were followed-up for from 6 to 23 months (averaged 11.6 months). The symptoms of all patients had primarily relieved and the patients coulde ambulate at 2 to 3 months after treatment. According to Johner-Wruhs critera, the therapeutic results were excellent in 10 cases, good in 8 cases, fair in 2 cases. No case had skin infection and skin necrosis. Treatment of Pilon fractures complicated with fractures of fibula with TEN has the advantages such as less invasion, high rate of bone union and less soft tissue complication, it is a safe and effective procedure.

  11. A Rare Nasal Bone Fracture: Anterior Nasal Spine Fracture

    Directory of Open Access Journals (Sweden)

    Egemen Kucuk

    2014-04-01

    Full Text Available Anterior nasal spine fractures are a quite rare type of nasal bone fractures. Associated cervical spine injuries are more dangerous than the nasal bone fracture. A case of the anterior nasal spine fracture, in a 18-year-old male was presented. Fracture of the anterior nasal spine, should be considered in the differential diagnosis of the midface injuries and also accompanying cervical spine injury should not be ignored.

  12. Conscious sedation for awake craniotomy in intraoperative magnetic resonance imaging operating theater

    Science.gov (United States)

    Takrouri, Mohamad Said Maani; Shubbak, Firas A.; Al Hajjaj, Aisha; Maestro, Rolando F. Del; Soualmi, Lahbib; Alkhodair, Mashael H.; Alduraiby, Abrar M.; Ghanem, Najeeb

    2010-01-01

    This case report describes the first case in intraoperative magnetic resonance imaging operating theater (iMRI OT) (BrainSuite®) of awake craniotomy for frontal lobe glioma excision in a 24-year-old man undergoing eloquent cortex language mapping intraoperatively. As he was very motivated to take pictures of him while being operated upon, the authors adapted conscious sedation technique with variable depth according to Ramsey's scale, in order to revert to awake state to perform the intended neurosurgical procedure. The patient tolerated the situation satisfactorily and was cooperative till the finish, without any event. We elicit in this report the special environment of iMRI OT for lengthy operation in pinned fixed patient having craniotomy. PMID:25885085

  13. Pubic insufficiency fracture: MRI findings

    International Nuclear Information System (INIS)

    Min, Tae Kyu; Lee, Yeon Soo; Park, Jeong Mi; Kim, Jee Young; Chung, Hong Jun; Lee, Eun Hee; Lee, Eun Ja; Kang, So Won; Han Tae Il

    2000-01-01

    To evaluate the characteristic MRI findings of pubic insufficiency fracture. In nine cases of pubic insufficiency fracture, the findings of plain radiography (n=9), MRI (n=9), and bone scintigraphy (n=8) were reviewed. We retrospectively analyzed, with regard to fracture site, the destructive pattern revealed by plain radiography, and uptake by other pelvic bones, as demonstrated by RI bone scanning. The MR findings evaluated were the fracture gap and its signal intensity, the site and signal intensity of the soft tissue mass, and other pelvic bone fractures. Plain radiography revealed osteolysis and sclerosis of pubic bone in eight of nine cases (89%), and parasymphyseal fractures in seven (78%). RI indicated uptake by the sacrum in six cases (66%), and by the ilium in three (33%). MR findings of fracture gap (seven cases, 78%) were hypo to isointensity on T1WI, hyper intensity on T2WI and the absence of contrast enhancement. Soft tissue masses were found in seven cases (78%); in four of these the location was parasymphyseal, and in three, surrounding muscle was involved. Hypo to isointensity was revealed by T1WI, hyperintensity by T2WI, and there was peripheral enhancement. Other associated pelvic bone fractures involved the sacrum in seven cases and the ilium in four. The characteristic MR findings of pubic insufficiency fracture were parasymphyseal location, fracture gap, peripherally enhanced soft tissue mass formation, and fractures of other pelvic bones, namely the sacrum and ilium

  14. Acute avulsion fractures of the pelvis in adolescent competitive athletes: prevalence, location and sports distribution of 203 cases collected

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, F.; Dragoni, S. [Sports Science Inst., Rome (Italy)

    2001-03-01

    Objective. To describe the prevalence, location and sports distribution of pelvic avulsion fractures in adolescent competitive athletes. Design and patients. One thousand two hundred and thirty-eight radiographs of the pelvis taken for focal traumatic symptoms in athletes with an age range of 11-35 years over a period of 22 years were reviewed. Results. One hundred and ninety-eight adolescent athletes were affected by 203 avulsion fractures of the pelvic apophyses (five cases presented multiple locations). The localisation was the ischial tuberosity (IT) in 109 cases, anterior inferior iliac spine (AIIS) in 45 cases, anterior superior iliac spine (ASIS) in 39 cases, superior corner of pubic symphysis (SCPS) in 7 cases and iliac crest (IC) in 3 cases. Soccer (74 cases) and gymnastics (55 cases) were the sports with the highest number of avulsion fractures documented. Conclusions. Apophyseal avulsion fractures of the pelvis in adolescent competitive athletes are most common in soccer and gymnastics. The lesions are usually the consequence of sudden and forceful muscle-tendon contractions during sport activities. Plain radiographs, are determinant for the diagnosis. (orig.)

  15. Acute avulsion fractures of the pelvis in adolescent competitive athletes: prevalence, location and sports distribution of 203 cases collected

    International Nuclear Information System (INIS)

    Rossi, F.; Dragoni, S.

    2001-01-01

    Objective. To describe the prevalence, location and sports distribution of pelvic avulsion fractures in adolescent competitive athletes. Design and patients. One thousand two hundred and thirty-eight radiographs of the pelvis taken for focal traumatic symptoms in athletes with an age range of 11-35 years over a period of 22 years were reviewed. Results. One hundred and ninety-eight adolescent athletes were affected by 203 avulsion fractures of the pelvic apophyses (five cases presented multiple locations). The localisation was the ischial tuberosity (IT) in 109 cases, anterior inferior iliac spine (AIIS) in 45 cases, anterior superior iliac spine (ASIS) in 39 cases, superior corner of pubic symphysis (SCPS) in 7 cases and iliac crest (IC) in 3 cases. Soccer (74 cases) and gymnastics (55 cases) were the sports with the highest number of avulsion fractures documented. Conclusions. Apophyseal avulsion fractures of the pelvis in adolescent competitive athletes are most common in soccer and gymnastics. The lesions are usually the consequence of sudden and forceful muscle-tendon contractions during sport activities. Plain radiographs, are determinant for the diagnosis. (orig.)

  16. Cemented hemi-arthroplasty in proximal femoral fractures in elderly with severe osteoporosis: A case series

    Directory of Open Access Journals (Sweden)

    Rahul M Salunkhe

    2012-01-01

    Full Text Available Context: Inter-trochanteric fractures in osteoporotic bones which are grossly comminuted are highly unstable and difficult to treat. Conservative treatment with traction and prolonged immobilization lands up with many complications and often fatality. Rate of failure with internal fixation with dynamic hip screw has been found to be high, especially in osteoporotic bones. Revision osteo-synthesis is technically demanding and leads to complications. Aim: To assess the efficacy of cemented hemiarthroplasty in the management of proximal femoral fractures in elderly patients with severe osteoporosis. Settings and Design: A Case series of 50 cases. Materials and Methods: We divided these fractures into three groups and accordingly the prosthesis was used. Group 1- intact calcar and lesser trochanter non-communited-AMP type of bipolar prosthesis, Group 2- fracture of calcar - Thompson′s type of bipolar prosthesis with calcar reconstruction, Group 3- group 2 + instability of postero-medial wall-modular type bipolar prosthesis with lesser trochanter and calcar reconstruction. Greater trochanter, calcar, and lesser trochanter were reconstructed with encirclage, tension band wiring, fashioned bone graft, or bone cement collar accordingly. Results: In our study of 50 cases with mean age 79.57 years, 20 cases were type 1, 19 type 2, and 11 type 3 fractures. The average Harris hip score was 79. Excellent to fair results were obtained at follow-up in 46 (92% and in 4 (8% results were poor. The mean Harris hip score was 83 (good in Group- I, 79 (Fair in Group- II, and 72 (Fair in Group- III patients. Average hospital stay was 12.5 days. There were four cases of superficial operative site infection which were treated with short course of oral antibiotics. Four cases died of medical complications, earliest being 3 months, and latest being 18 months. No case of loosening of the prosthesis, break in the cement or sinking of prosthesis was seen.

  17. Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail.

    NARCIS (Netherlands)

    Schipper, I.B.; Steyerberg, E.W.; Castelein, R.M.; Heijden, F.H. van der; Hoed, P.T. den; Kerver, A.J.; Vugt, A.B. van

    2004-01-01

    The proximal femoral nail (PFN) is a recently introduced intramedullary system, designed to improve treatment of unstable trochanteric fractures of the hip. In a multicentre prospective clinical study, the intra-operative use, complications and outcome of treatment using the PFN (n = 211) were

  18. Success of intraoperative scintigraphic detection to complete eradicate of persistent osteoid osteoma

    International Nuclear Information System (INIS)

    Haddam, A.; Bsiss, A.; BenRais, N.; Lahlou, A.; Essahli, Y.; Boufetal; Lamzaf, O.; El Yaacoubi, M.

    2009-01-01

    The osteoid osteoma is a small benign, painful, bony tumour in which the treatment consists of a complete surgical ablation. The cases of recurrence often correspond to an incomplete surgical ablation. We report, in this work, the advantage of isotopic intraoperative marking for an accurate and complete excision of the pathological lesion in a young patient, during his surgical resumption after the short-term failure of the first intervention, which was accomplished without intraoperative location, and completed with a literature review. (authors)

  19. Microscope-integrated intraoperative optical coherence tomography-guided small-incision lenticule extraction: New surgical technique.

    Science.gov (United States)

    Sharma, Namrata; Urkude, Jayanand; Chaniyara, Manthan; Titiyal, Jeewan S

    2017-10-01

    We describe the surgical technique of microscope-integrated intraoperative optical coherence tomography (OCT)-guided small-incision lenticule extraction. The technique enables manual tracking of surgical instruments and identification of the desired dissection plane. It also helps discern the relation between the dissector and the intrastromal lenticule. The dissection plane becomes hyperreflective on dissection, ensuring complete separation of the intrastromal lenticule from the overlying and underlying stroma. Inadvertent posterior plane entry, cap-lenticule adhesion, incomplete separation of the lenticule, creation of a false plane, and lenticule remnants may be recognized intraoperatively so corrective steps can be taken immediately. In cases with a hazy overlying cap, microscope-integrated intraoperative OCT enables localization and extraction of the lenticule. The technique is helpful for inexperienced surgeons, especially in cases with low amplitudes of refractive errors, ie, thin lenticules. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. Traumatic posterior atlantoaxial dislocation without fracture of the odontoid process: A case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Yong Kyun; Park, Jin Gyoon; Jung, Hyun Nyeong [Dept. of Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of); Kim, Ju Won [Dept. of Radiology, Chonnam National University Hwasun Hospital, Hwasun (Korea, Republic of); Lee, Seung Jin [Dept. of Radiology, Chonnam National University Bitgoeul Hospital, Gwangju (Korea, Republic of)

    2017-03-15

    Traumatic posterior atlantoaxial dislocation without odontoid fracture is very rare. Patient prognosis depends on the neurologic symptoms or the extent of damage to the structures. In this case, a 78-year-old-male suffered a posterior atlantoaxial dislocation without odontoid fracture after a traffic accident. We report this case because an exact diagnosis and proper treatment can reduce the neurologic complications in patients with posterior atlantoaxial dislocation.

  1. Brain tumors in eloquent areas: A European multicenter survey of intraoperative mapping techniques, intraoperative seizures occurrence, and antiepileptic drug prophylaxis.

    Science.gov (United States)

    Spena, Giannantonio; Schucht, Philippe; Seidel, Kathleen; Rutten, Geert-Jan; Freyschlag, Christian Franz; D'Agata, Federico; Costi, Emanule; Zappa, Francesca; Fontanella, Marco; Fontaine, Denys; Almairac, Fabien; Cavallo, Michele; De Bonis, Pasquale; Conesa, Gerardo; Foroglou, Nicholas; Gil-Robles, Santiago; Mandonnet, Emanuel; Martino, Juan; Picht, Thomas; Viegas, Catarina; Wager, Michel; Pallud, Johan

    2017-04-01

    Intraoperative mapping and monitoring techniques for eloquent area tumors are routinely used world wide. Very few data are available regarding mapping and monitoring methods and preferences, intraoperative seizures occurrence and perioperative antiepileptic drug management. A questionnaire was sent to 20 European centers with experience in intraoperative mapping or neurophysiological monitoring for the treatment of eloquent area tumors. Fifteen centers returned the completed questionnaires. Data was available on 2098 patients. 863 patients (41.1%) were operated on through awake surgery and intraoperative mapping, while 1235 patients (58.8%) received asleep surgery and intraoperative electrophysiological monitoring or mapping. There was great heterogeneity between centers with some totally AW oriented (up to 100%) and other almost totally ASL oriented (up to 92%) (31% SD). For awake surgery, 79.9% centers preferred an asleep-awake-asleep anesthesia protocol. Only 53.3% of the centers used ECoG or transcutaneous EEG. The incidence of intraoperative seizures varied significantly between centers, ranging from 2.5% to 54% (p mapping technique and the risk of intraoperative seizures. Moreover, history of preoperative seizures can significantly increase the risk of intraoperative seizures (p mapping and monitoring protocols and the management of peri- and intraoperative seizures. This data can help identify specific aspects that need to be investigated in prospective and controlled studies.

  2. [Identification and management of intra-operative suspicious tissues in 20 transsphenoidal surgery cases].

    Science.gov (United States)

    Liu, Jun-Feng; Ke, Chang-Shu; Chen, Xi; Xu, Yu; Zhang, Hua-Qiu; Chen, Juan; Gan, Chao; Li, Chao-Xi; Lei, Ting

    2013-05-01

    To determine appropriate protocols for the identification and management of intra operative suspicious tissues during transsphenoidal surgery. Clinical data and pathological reports of 20 patients with intra-operative suspicious tissues during transsphenoidal surgeries were analyzed retrospectively. The methods for discriminating between adenoma and normal pituitary tissues were reviewed. The postoperative pathological reports revealed that adenoma and normal pituitary tissues coexisted in 9 samples, while 5 samples were identified as normal pituitary tissues, 2 as adenoma tissues, and 4 as other tissues. Adenomas were distinguished from normal pituitary tissues on the basis of intra-operative appearance, texture, blood supply and possible existence of boundary. If decisions are difficult to made during surgeries from the appearance of the suspicious tissues, pathological examinations are advised as a guidance for the next steps.

  3. Sequential Proximal Tibial Stress Fractures associated with Prolonged usage of Methotrexate and Corticosteroids: A Case Report

    Directory of Open Access Journals (Sweden)

    Tan TJL

    2015-11-01

    Full Text Available Stress fractures of the proximal tibia metaphysis are rare in the elderly. We present a case of a 65-year old male who developed sequential proximal tibia stress fractures associated with prolonged usage of methotrexate and prednisolone within a span of 18 months. Magnetic Resonance Imaging revealed an incomplete stress fracture involving the medial proximal tibial region. The patient was treated with stemmed total knee arthroplasty (TKA bilaterally. Stress fractures should be considered in patients with atypical knee pain who have a history of methotrexate and prednisolone usage. TKA is an effective treatment in stress fractures of the proximal tibia.

  4. Traumatic fracture-dislocation of the hip following rugby tackle: a case report

    Directory of Open Access Journals (Sweden)

    Venkatachalam Santosh

    2009-12-01

    Full Text Available Abstract Posterior fracture-dislocation of hip is uncommonly encountered in rugby injuries. We report such a case in an adult while playing rugby. The treating orthopaedician can be caught unaware and injuries in such sports can be potentially misdiagnosed as hip sprains. Immediate reduction of the dislocation was performed in theatres. The fracture was fixed with two lag screws and a neutralization plate. This led to early rehabilitation and speedy recovery with return to sporting activities by 12 months.

  5. Fracture of the styloid process associated with the mandible fracture

    Directory of Open Access Journals (Sweden)

    K N Dubey

    2013-01-01

    Full Text Available Fracture of the styloid process (SP of temporal bone is an uncommon injuries. Fracture of the SP can be associated with the facial injuries including mandible fracture. However, injury to the SP may be concealed and missed diagnosis may lead to the improper or various unnecessary treatments. A rare case of SP fracture associated with the ipsilateral mandibular fracture and also the diagnostic and management considerations of the SP fracture are discussed.

  6. Radiological study of the mandibular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ju Won; Kim, Kyoung A; Koh, Kwang Jun [Department of Oral and Maxillofacial Radiology, School of Dentistry, and Institute of Oral Bio Science, Chonbuk National University, Jeonju (Korea, Republic of)

    2009-06-15

    To classify and evaluate mandibular fractures. The author classified mandibular fractures of 284 patients who were referred to the Chonbuk National University Dental Hospital during the period from March 2004 to June 2007. This study was based on the conventional radiographs as well as computed tomographs which were pertained to the 284 patients who have had the mandibular fractures including the facial bone fractures. And mandibular fractures were classified with respect to gender, age, site and type of the fractures. More frequently affected gender with mandibular fracture was male with the ratio of 3.3 : 1. The most frequently affected age with mandibular fracture was third decade (38%), followed by fourth decade (16%), second decade (15%), fifth decade (11%), sixth decade (7%), seventh decade (5%), eighth decade (4%), first decade (4%), and ninth decade (0.3%). The most frequent type of mandibular fracture was single fracture (58%), followed by double fracture (39%), triple fracture (3%). The most common site of mandibular fracture was mandibular condyle as 113 cases (27.7%) and the next was mandibular symphysis as 109 cases (26.7%), mandibular angle as 103 cases (25.3%), mandibular body as 83 cases (20.3%) in order. The sum of fracture sites were 408 sites and there were 1.4 fracture sites per one patient. The number of mandible fractures accompanied with facial bone fractures were 41 cases (14.4%). The results showed the most frequent type and common site of mandibular fracture was single fracture and mandibular condyle respectively.

  7. Radiological study of the mandibular fractures

    International Nuclear Information System (INIS)

    Kim, Ju Won; Kim, Kyoung A; Koh, Kwang Jun

    2009-01-01

    To classify and evaluate mandibular fractures. The author classified mandibular fractures of 284 patients who were referred to the Chonbuk National University Dental Hospital during the period from March 2004 to June 2007. This study was based on the conventional radiographs as well as computed tomographs which were pertained to the 284 patients who have had the mandibular fractures including the facial bone fractures. And mandibular fractures were classified with respect to gender, age, site and type of the fractures. More frequently affected gender with mandibular fracture was male with the ratio of 3.3 : 1. The most frequently affected age with mandibular fracture was third decade (38%), followed by fourth decade (16%), second decade (15%), fifth decade (11%), sixth decade (7%), seventh decade (5%), eighth decade (4%), first decade (4%), and ninth decade (0.3%). The most frequent type of mandibular fracture was single fracture (58%), followed by double fracture (39%), triple fracture (3%). The most common site of mandibular fracture was mandibular condyle as 113 cases (27.7%) and the next was mandibular symphysis as 109 cases (26.7%), mandibular angle as 103 cases (25.3%), mandibular body as 83 cases (20.3%) in order. The sum of fracture sites were 408 sites and there were 1.4 fracture sites per one patient. The number of mandible fractures accompanied with facial bone fractures were 41 cases (14.4%). The results showed the most frequent type and common site of mandibular fracture was single fracture and mandibular condyle respectively.

  8. [Case control study of fractures-dislocations of ankle joint with conservative and operative treatment].

    Science.gov (United States)

    Zhang, Song-Tu; Lin, Yi-Rong; Chen, Lian-Yuan

    2010-10-01

    To compare the clinical efficacy of grade III, IV supination-eversion fractures-dislocations of ankle joint between manipulative treatment and operative treatment. From September 2007 to December 2008, the clinical data of 60 patients with grade III, IV supination-eversion fractures-dislocations of ankle joint were retrospectively analyzed. There were 32 males and 28 females, ranging in age from 18 to 70 years with an average age of 38.17 years. All patients were respectively treated with manipulative treatment (conservative group, 30 cases) and operative treatment (operative group, 30 cases). The joint function was compared with Mazur standard; the reduction and shifting of fractures were observed with X-ray; the hospitalization day and the therapeutic cost were compared between two groups. All patients were followed up with an average of 15.27 months (ranged, 6 to 25 months). In conservative group, 16 cases got excellent result in joint function, 10 good, 3 fair, 1 poor; in operative group, 20 cases got excellent result, 8 good, 2 fair, 0 poor. In conservative group in the X-ray showed 25 cases obtained excellent and good reduction, 4 fair, 1 poor; and in operative group in the X-ray showed 28 cases obtained excellent and good reduction, 2 fair, 0 poor. There was no significant difference at the joint function and X-ray film after treatment between two groups (P > 0.05). The hospital day was respectively (7.87 +/- 3.34), (17.37 +/- 4.64) d in conservative group and operative group; and the therapeutic cost was respectively (2 506.67 +/- 649.10), (11 473.33 +/- 1 564.90) yuan. There was significant difference at hospital day and therapeutic cost between two groups (P fractures and dislocations of ankle joint. However, conservative treatment has advantage of high safety factor, low therapeutic cost, can reduce medical costs for patients.

  9. A case report of an isolated fracture through the radial bicipital tuberosity

    Directory of Open Access Journals (Sweden)

    Kanta Imao

    Full Text Available Introduction: Generally, anatomical reduction of shaft fractures through operative treatment is necessary to restore the anatomical relationship of the forearm bones. However, a number of nerves and vessels are located in the proximal radius, which complicates surgery. In this study, we aimed to reduce postoperative complications by using a posterior approach. Presentation of case: We describe an isolated fracture through the radial bicipital tuberosity in a 69-year-old man caused by direct blunt force and our management of the fracture. The patient underwent an operation for the fracture under brachial plexus block. The injury was explored using the posterior approach, and plate fixation was performed after confirming the absence of obstacles to rotation on pronation and supination. One year later, the patient did not have any difficulties in activities of daily living. Discussion: Since an isolated fracture through the radial bicipital tuberosity is more distal than the radial head and neck and more proximal than a common radius diaphysis fracture, we had to consider a different operative approach. The nerve and blood vessels of the forearm, such as the radial nerve and artery, run in a complicated fashion around the proximal radius; thus, we chose the posterior approach because of its simpler surgical technique and lower complication risk, compared with the anterior approach. Conclusion: Surgeons can obtain a favorable treatment result using the posterior approach to the fracture and reduce complications by ensuring with rigid fixation using a locking plate. Keywords: Radial bicipital tuberosity, Posterior approach, Posterior interosseous nerve, Shaft fracture

  10. Managing a grossly comminuted and infected mandibular fracture using a maxillary extra-oral distractor as stabilizing agent: A clinical case report

    Directory of Open Access Journals (Sweden)

    Ding Ming Chao

    2017-06-01

    Full Text Available Facial fracture management dates as early as Hippocratic era. Comminuted mandibular fractures are one of the challenging clinical condition requiring high surgical expertise to achieve a good functional and esthetic outcome. In presence of infection and other facial fractures managing comminuted mandibular fracture becomes more challenging.Here we present a case of grossly comminuted and infected mandibular fracture with delayed presentation managed by using maxillary distractor as stabilizing agent. Using a maxillary distractor for managing a fractured mandible has been seldom reported in literature. Current case report gives idea to practicing clinician about the possibility of treatment beyond the established principles. Keywords: Mandibular fracture, Maxillary distractor, Infection

  11. Management of mandibular body fractures in pediatric patients: a case report with review of literature.

    Science.gov (United States)

    John, Baby; John, Reena R; Stalin, A; Elango, Indumathi

    2010-10-01

    Mandibular fractures are relatively less frequent in children when compared to adults, which may be due to the child's protected anatomic features and infrequent exposure of children to alcohol related traffic accidents. Treatment principles of mandibular fractures differ from that of adults due to concerns regarding mandibular growth and development of dentition. A case of a 4.5-year-old boy with fractured body of mandible managed by closed reduction using open occlusal acrylic splint and circum mandibular wiring is presented. This article also provides a review of literature regarding the management of mandibular body fracture in young children.

  12. Management of mandibular body fractures in pediatric patients: A case report with review of literature

    Directory of Open Access Journals (Sweden)

    Baby John

    2010-01-01

    Full Text Available Mandibular fractures are relatively less frequent in children when compared to adults, which may be due to the child′s protected anatomic features and infrequent exposure of children to alcohol related traffic accidents. Treatment principles of mandibular fractures differ from that of adults due to concerns regarding mandibular growth and development of dentition. A case of a 4.5-year-old boy with fractured body of mandible managed by closed reduction using open occlusal acrylic splint and circum mandibular wiring is presented. This article also provides a review of literature regarding the management of mandibular body fracture in young children.

  13. Two case examples of pelvic fractures in medieval populations from central Europe.

    Science.gov (United States)

    Hofmann, Maria Ines; Papageorgopoulou, Christina; Böni, Thomas; Rühli, Frank J

    2010-01-01

    Pelvic fractures are considered to be uncommon and difficult to treat, even in the modern medical literature. Serious and eventually life-threatening associated injuries may occur, requiring emergency abdominal, vascular or neurologic surgery. Pelvic fractures can also be managed non-operatively; however, a considerable dispute exists on the suitable management strategy. The treatment and healing of such injuries in the bioarchaeological record, is therefore of great interest for anthropological and medico-historical studies. Fractures of the pelvis are rarely reported in the anthropological literature either due to poor preservation of the innominate bone or lack of adequate examination. Here we present two cases of pelvic fractures observed on two adult male individuals from two European medieval sites. They differ in severity and in the pattern of healing. They are both adequately healed and probably had no acute life-threatening consequences, which gives us some insight into the medical knowledge and means of management of past populations.

  14. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia.

    Science.gov (United States)

    Seyhan, Mustafa; Guler, Olcay; Mahirogullari, Mahir; Donmez, Ferdi; Gereli, Arel; Mutlu, Serhat

    2018-02-01

    Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of the tibia. Sixty-two patients (26 females, 36 males) were included in this retrospective study. Of the removed nails, 24 were of stainless steel and 38 of titanium. Preoperative and intraoperative parameters, such as implant discomfort, anterior knee pain, operating time and amount of bleeding, and postoperative outcomes were evaluated for each patient. Titanium nail group had more, but not statistically significant, intraoperative complications than stainless steel group during the removal of nails (p = .4498). Operating time and amount of intraoperative bleeding were significantly higher in titanium group than stainless steel group (p = .0306 and p titanium nails than those of stainless steel nails, whereas there was no difference in terms of postoperative SF-36 and KSS scores. In conclusion, although greater bone contact with titanium increases implant stability, nail removal is more difficult, resulting in more longer surgical operation and more intraoperative bleeding. Therefore, we do not recommend titanium nail removal in asymptomatic patients.

  15. Manual Physical Therapy Following Immobilization for Stable Ankle Fracture: A Case Series.

    Science.gov (United States)

    Painter, Elizabeth E; Deyle, Gail D; Allen, Christopher; Petersen, Evan J; Croy, Theodore; Rivera, Kenneth P

    2015-09-01

    Case series. Ankle fractures commonly result in persistent pain, stiffness, and functional impairments. There is insufficient evidence to favor any particular rehabilitation approach after ankle fracture. The purpose of this case series was to describe an impairment-based manual physical therapy approach to treating patients with conservatively managed ankle fractures. Patients with stable ankle fractures postimmobilization were treated with manual physical therapy and exercise targeted at associated impairments in the lower limb. The primary outcome measure was the Lower Extremity Functional Scale. Secondary outcome measures included the ankle lunge test, numeric pain-rating scale, and global rating of change. Outcome measures were collected at baseline (performed within 7 days of immobilization removal) and at 4 and 12 weeks postbaseline. Eleven patients (mean age, 39.6 years; range, 18-64 years; 2 male), after ankle fracture-related immobilization (mean duration, 48 days; range, 21-75 days), were treated for an average of 6.6 sessions (range, 3-10 sessions) over a mean of 46.1 days (range, 13-81 days). Compared to baseline, statistically significant and clinically meaningful improvements were observed in Lower Extremity Functional Scale score (P = .001; mean change, 21.9 points; 95% confidence interval: 10.4, 33.4) and in the ankle lunge test (P = .001; mean change, 7.8 cm; 95% confidence interval: 3.9, 11.7) at 4 weeks. These changes persisted at 12 weeks. Statistically significant and clinically meaningful improvements in self-reported function and ankle range of motion were observed at 4 and 12 weeks following treatment with impairment-based manual physical therapy. All patients tolerated treatment well. Results suggest that this approach may have efficacy in this population. Therapy, level 4.

  16. Intraoperative Death During Cervical Spinal Surgery: A Retrospective Multicenter Study.

    Science.gov (United States)

    Wang, Jeffrey C; Buser, Zorica; Fish, David E; Lord, Elizabeth L; Roe, Allison K; Chatterjee, Dhananjay; Gee, Erica L; Mayer, Erik N; Yanez, Marisa Y; McBride, Owen J; Cha, Peter I; Arnold, Paul M; Fehlings, Michael G; Mroz, Thomas E; Riew, K Daniel

    2017-04-01

    A retrospective multicenter study. Routine cervical spine surgeries are typically associated with low complication rates, but serious complications can occur. Intraoperative death is a very rare complication and there is no literature on its incidence. The purpose of this study was to determine the intraoperative mortality rates and associated risk factors in patients undergoing cervical spine surgery. Twenty-one surgical centers from the AOSpine North America Clinical Research Network participated in the study. Medical records of patients who received cervical spine surgery from January 1, 2005, to December 31, 2011, were reviewed to identify occurrence of intraoperative death. A total of 258 patients across 21 centers met the inclusion criteria. Most of the surgeries were done using the anterior approach (53.9%), followed by posterior (39.1%) and circumferential (7%). Average patient age was 57.1 ± 13.2 years, and there were more male patients (54.7% male and 45.3% female). There was no case of intraoperative death. Death during cervical spine surgery is a very rare complication. In our multicenter study, there was a 0% mortality rate. Using an adequate surgical approach for patient diagnosis and comorbidities may be the reason how the occurrence of this catastrophic adverse event was prevented in our patient population.

  17. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    OpenAIRE

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare en...

  18. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures.

    Science.gov (United States)

    Gulbahar, Gultekin; Kaplan, Tevfik; Turker, Hasan Bozkurt; Gundogdu, Ahmet Gokhan; Han, Serdar

    2015-01-01

    First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  19. Nurse case-manager vs multifaceted intervention to improve quality of osteoporosis care after wrist fracture: randomized controlled pilot study.

    Science.gov (United States)

    Majumdar, S R; Johnson, J A; Bellerose, D; McAlister, F A; Russell, A S; Hanley, D A; Garg, S; Lier, D A; Maksymowych, W P; Morrish, D W; Rowe, B H

    2011-01-01

    Few outpatients with fractures are treated for osteoporosis in the years following fracture. In a randomized pilot study, we found a nurse case-manager could double rates of osteoporosis testing and treatment compared with a proven efficacious quality improvement strategy directed at patients and physicians (57% vs 28% rates of appropriate care). Few patients with fractures are treated for osteoporosis. An intervention directed at wrist fracture patients (education) and physicians (guidelines, reminders) tripled osteoporosis treatment rates compared to controls (22% vs 7% within 6 months of fracture). More effective strategies are needed. We undertook a pilot study that compared a nurse case-manager to the multifaceted intervention using a randomized trial design. The case-manager counseled patients, arranged bone mineral density (BMD) tests, and prescribed treatments. We included controls from our first trial who remained untreated for osteoporosis 1-year post-fracture. Primary outcome was bisphosphonate treatment and secondary outcomes were BMD testing, appropriate care (BMD test-treatment if bone mass low), and costs. Forty six patients untreated 1-year after wrist fracture were randomized to case-manager (n = 21) or multifaceted intervention (n = 25). Median age was 60 years and 68% were female. Six months post-randomization, 9 (43%) case-managed patients were treated with bisphosphonates compared with 3 (12%) multifaceted intervention patients (relative risk [RR] 3.6, 95% confidence intervals [CI] 1.1-11.5, p = 0.019). Case-managed patients were more likely than multifaceted intervention patients to undergo BMD tests (81% vs 52%, RR 1.6, 95%CI 1.1-2.4, p = 0.042) and receive appropriate care (57% vs 28%, RR 2.0, 95%CI 1.0-4.2, p = 0.048). Case-management cost was $44 (CDN) per patient vs $12 for the multifaceted intervention. A nurse case-manager substantially increased rates of appropriate testing and treatment for osteoporosis in

  20. SU-F-T-44: A Comparison of the Pre-Plan, Intra-Operative Plan, and Post-Implant Dosimetry for a Prostate Implant Case Using Prefabricated Linear Polymer-Encapsulated Pd-103

    International Nuclear Information System (INIS)

    Sheu, R; Powers, A; McGee, H; Stock, R; Lo, Y

    2016-01-01

    Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, and 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.

  1. SU-F-T-44: A Comparison of the Pre-Plan, Intra-Operative Plan, and Post-Implant Dosimetry for a Prostate Implant Case Using Prefabricated Linear Polymer-Encapsulated Pd-103

    Energy Technology Data Exchange (ETDEWEB)

    Sheu, R; Powers, A; McGee, H; Stock, R; Lo, Y [Mount Sinai Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: To investigate the reproducibility and limitations of Pd-103 prostate brachytherapy using fixed length linear sources (CivaString). Methods: An LDR prostate brachytherapy case which was preplanned on MR images with prefabricated linear polymer-encapsulated Pd-103 sources (CivaString) was studied and compared with ultrasound based intra-operative planning and CT based post-implant dosimetry. We evaluated the following parameters among the three studies: prostate geometry (volume and cross sectional area), needle position and alignment deviations, and dosimetry parameters (D90). Results: The prostate volumes and axial cross sectional areas at center of prostate were measured as 41.8, 39.3 and 36.8 cc, and 14.9, 14.3, and 11.3 respectively on pre-plan MR, inter-op US, and post-implant CT studies. The deviation of prostate volumes and axial cross sectional areas measured on pre-planning MR and intra-operative US were within 5%. 17 out of 19 pre-planned needles were positioned within 5mm (the template grid size). One needle location was adjusted intra-operatively and another needle was removed due to proximity to urethra. The needle pathways were not always parallel to the trans-rectal probe due to the flexibility of CivaString. The angle of deviation was up to 10 degrees. Two pairs of needles were exchanged to better fit the length of prostate at the time of implant. This resulted in a prostate D90 of 153.8 Gy (124%) and 131.4 Gy (106.7%) for intra-op and PID respectively. Conclusion: Preplanning is a necessary part of implants performed with prefabricated linear polymer sources. However, as is often the case, there were real-time deviations from the pre-plan. Intra-op planning provides the ability conform to anatomy at the time of implant. Therefore, we propose to develop a systematic way to order extra strings of different length to provide the flexibility to perform intra-operative planning with fixed length strands.

  2. Acute flexor tendon injury following midshaft radius and ulna fractures in a paediatric patient

    Directory of Open Access Journals (Sweden)

    James Williams

    2018-06-01

    Full Text Available Delayed rupture of the extensor and flexor tendons are recognised complications of distal radius fractures. However, acute flexor tendon rupture in the context of forearm fractures is rare. A twelve-year-old female sustained midshaft fractures of the radius and ulna. Intra-operatively the flexor pollicis longus (FPL was found to be stripped from its musculotendinous junction at the level of the fracture fragment. The ruptured tendon was repaired using a modified Krackow technique at the time of fracture fixation. The repair was protected in plaster of Paris prior to referral to the paediatric hand clinic. The patient made a full recovery. Flexor tendon injury is a rare but potentially devastating consequence of acute forearm fractures. High energy trauma, significant volar angulation of the fracture fragment and clinical signs of flexor tendon injury should raise suspicion of this injury. A high index of suspicion in conjunction with repeat clinical examination of flexor tendon function should be performed before opting for closed management or intramedullary nailing in paediatric patients. Keywords: Acute, Flexor, Tendon, Fracture, Radius, Paediatric

  3. Intraoperative Magnetic Resonance Imaging for Cranial and Spinal Cases Using Preexisting "C" Shaped Three Side Open 0.2 Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    Tewari, Vinod Kumar; Tripathi, Ravindra; Aggarwal, Subodh; Hussain, Mazhar; Das Gupta, Hari Kishan

    2017-01-01

    The existing Intraoperative MRI (IMRI) of developed countries is too costly to be affordable in any developing country and out of the reach of common and poor people of developing country at remote areas. We have used the pre-existing (refurbished) 3 side open "C" shaped 0.2 Tesla MRI for IMRI in a very remote area. In this technique the 0.2 Tesla MRI and the operating theatre were merged. MRI table was used as an operation table. We have operated 36 cases via IMRI from November 2005 to till date. First case operated was on 13 th nov 2005. Low (0.2) Tesla open setup costs very low (around Rs 40 lakhs) so highly affordable to management and thus to patients, used for diagnostic and therapeutic purposes both, the equipments like Nitrous, oxygen and suction is outside the MRI room so no noise inside operative room, positioning the patient didn't take much time due to manual adjustments, no special training to nurses and technicians required because of low (0.2) Tesla power of magnet and same instruments and techniques, sequencing took only 1.31 mints per sequence and re registration is not required since we always note down the two orthogonal axis in x and y axis in preoperative imaging and we were able to operate on posterior fossa tumors as well because of no head fixation except with leucoplast strap. Moreover the images we got intraoperative are highly acceptable. Three side open 0.2 Tesla MRI system, if used for intraoperative guidance, is highly affordable and overcomes the limitations of western setup of IMRI. Postoperative MRI images were highly acceptable and also highly affordable too.

  4. Management of mandibular body fractures in pediatric patients: A case report with review of literature

    OpenAIRE

    Baby John; Reena R John; A Stalin; Indumathi Elango

    2010-01-01

    Mandibular fractures are relatively less frequent in children when compared to adults, which may be due to the child's protected anatomic features and infrequent exposure of children to alcohol related traffic accidents. Treatment principles of mandibular fractures differ from that of adults due to concerns regarding mandibular growth and development of dentition. A case of a 4.5-year-old boy with fractured body of mandible managed by closed reduction using open occlusal acrylic splint and ci...

  5. Monteggia fracture dislocation equivalents - analysis of eighteen cases treated by open reduction and internal fixation

    Directory of Open Access Journals (Sweden)

    Singh Ajay Pal

    2012-02-01

    Full Text Available 【Abstract】 Objective: Monteggia fracture dislocation equivalent, though already described by Bado, is still an unclassified entity. We aimed to retrospectively analyze 18 cases of Monteggia variants and discuss the injury mechanisms, management, and outcome along with a review of the literature. Methods: A retrospective record of Monteggia fracture dislocation (2003-2008 was reviewed from medical record department of our institute. Classic Monteggia fracture dislocation, children below 12 years or adults over 50 years, as well as open grade II & III cases were excluded from this study. Monteggia variant inclusion criteria included fracture of the proximal ulna together with a fracture of the radial head or neck and skeletal maturity. Totally 26 patients were identified with Monteggia variants and 18 were available for follow-up, including 11 males and 7 females with the mean age of 35 years. The ulna fracture was treated by compression plating along with tension band wiring. Radial head/neck was reconstructed in 12 patients while excised in 6 patients. Results: Follow-up ranged from 1-4 years, mean 2.6 years. Patients were assessed clinicoradiologically. Mayo Elbow Performance Score was employed to assess the outcomes. At final follow-up, the results were excellent in 10 patients, good in 4, fair in 2 and poor in 2. Mean range of motion of the elbow was 20°, 116°, 50° and 55° for extension, flexion, pronation and supination, respectively. Two patients had complications in the form of heterotopic ossification and stiffness of the elbow. One nonunion ulna, primarily treated by tension band wiring, was managed by refixation with locking reconstruction plate and bone grafting. Bone grafting was only required in this patient for nonunion. Another patient had implants removed on his request. The results in our series closely correlated with extent of intraarticular damage, coronoid fracture and comminuted fractures. Conclusions: Monteggia

  6. Utility of Indocyanine Green Fluorescence Imaging for Intraoperative Localization in Reoperative Parathyroid Surgery.

    Science.gov (United States)

    Sound, Sara; Okoh, Alexis; Yigitbas, Hakan; Yazici, Pinar; Berber, Eren

    2015-10-27

    Due to the variations in anatomic location, the identification of parathyroid glands may be challenging. Although there have been advances in preoperative imaging modalities, there is still a need for an accurate intraoperative guidance. Indocyanine green (ICG) is a new agent that has been used for intraoperative fluorescence imaging in a number of general surgical procedures. Its utility for parathyroid localization in humans has not been reported in the literature. We report 3 patients who underwent reoperative neck surgery for primary hyperparathyroidism. Using a video-assisted technique with intraoperative ICG fluorescence imaging, the parathyroid glands were recognized and removed successfully in all cases. Surrounding soft tissue structures remained nonfluorescent, and could be distinguished from the parathyroid glands. This report suggests a potential utility of ICG imaging in intraoperative localization of parathyroid glands in reoperative neck surgery. Future work is necessary to assess its benefit for first-time parathyroid surgery. © The Author(s) 2015.

  7. The Dutch Linguistic Intraoperative Protocol: a valid linguistic approach to awake brain surgery.

    Science.gov (United States)

    De Witte, E; Satoer, D; Robert, E; Colle, H; Verheyen, S; Visch-Brink, E; Mariën, P

    2015-01-01

    Intraoperative direct electrical stimulation (DES) is increasingly used in patients operated on for tumours in eloquent areas. Although a positive impact of DES on postoperative linguistic outcome is generally advocated, information about the neurolinguistic methods applied in awake surgery is scarce. We developed for the first time a standardised Dutch linguistic test battery (measuring phonology, semantics, syntax) to reliably identify the critical language zones in detail. A normative study was carried out in a control group of 250 native Dutch-speaking healthy adults. In addition, the clinical application of the Dutch Linguistic Intraoperative Protocol (DuLIP) was demonstrated by means of anatomo-functional models and five case studies. A set of DuLIP tests was selected for each patient depending on the tumour location and degree of linguistic impairment. DuLIP is a valid test battery for pre-, intraoperative and postoperative language testing and facilitates intraoperative mapping of eloquent language regions that are variably located. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Talar body fatigue stress fractures: three cases observed in elite female gymnasts

    International Nuclear Information System (INIS)

    Rossi, F.; Dragoni, S.

    2005-01-01

    To introduce and emphasize the clinical and radiological findings of three talar body fatigue stress fractures in competitive athletes. Clinical and radiographic skeletal records of 24,562 athletes taken between 1962 and 2002 were retrospectively reviewed. Among these, 6851 files related to acute foot and ankle injuries or chronic post-traumatic sequelae were found. There were 925 (3.76%) stress fatigue fractures selected from the whole collection. Among these there were three cases (0.32%) of talar body stress fractures diagnosed in elite female gymnasts 15 - 17 years old. The negative first radiograph become positive 4-6 weeks later. Scintigraphy was positive at an early stage and consistent for the diagnosis. CT and MRI gave positive results 1-2 weeks after the beginning of symptoms which were always greatly diagnostic. The sports medicine literature lacks reports of talar body fatigue stress fractures. The poor initial sensitivity of radiography makes it problematic to establish an early diagnosis. A wise combination of scintigraphy, CT and MRI has therefore to be relied upon. Familiarity with this rare location for a stress fracture may prevent delayed diagnosis and long-lasting damage, both of which are important factors in competitive athletes. (orig.)

  9. Talar body fatigue stress fractures: three cases observed in elite female gymnasts

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, F. [National Institute of Sports Medicine of the Italian Olympic Committee, Rome (Italy); Dragoni, S. [National Institute of Sports Medicine of the Italian Olympic Committee, Rome (Italy); Istituto Nazionale di Medicina dello Sport, Rome (Italy)

    2005-07-01

    To introduce and emphasize the clinical and radiological findings of three talar body fatigue stress fractures in competitive athletes. Clinical and radiographic skeletal records of 24,562 athletes taken between 1962 and 2002 were retrospectively reviewed. Among these, 6851 files related to acute foot and ankle injuries or chronic post-traumatic sequelae were found. There were 925 (3.76%) stress fatigue fractures selected from the whole collection. Among these there were three cases (0.32%) of talar body stress fractures diagnosed in elite female gymnasts 15 - 17 years old. The negative first radiograph become positive 4-6 weeks later. Scintigraphy was positive at an early stage and consistent for the diagnosis. CT and MRI gave positive results 1-2 weeks after the beginning of symptoms which were always greatly diagnostic. The sports medicine literature lacks reports of talar body fatigue stress fractures. The poor initial sensitivity of radiography makes it problematic to establish an early diagnosis. A wise combination of scintigraphy, CT and MRI has therefore to be relied upon. Familiarity with this rare location for a stress fracture may prevent delayed diagnosis and long-lasting damage, both of which are important factors in competitive athletes. (orig.)

  10. Intraoperative dreams reported after general anaesthesia are not early interpretations of delayed awareness.

    Science.gov (United States)

    Samuelsson, P; Brudin, L; Sandin, R H

    2008-07-01

    Dreams are more frequently reported than awareness after surgery. We define awareness as explicit recall of real intraoperative events during anaesthesia. The importance of intraoperative dreaming is poorly understood. This study was performed to evaluate whether intraoperative dreams can be associated with, or precede, awareness. We also studied whether dreams can be related to case-specific parameters. A cohort of 6991 prospectively included patients given inhalational anaesthesia were interviewed for dreams and awareness at three occasions; before they left the post-anaesthesia care unit, days 1-3 and days 7-14 after the operation. Uni- and multivariate statistical relations between dreams, awareness and case-specific parameters were assessed. Two hundred and thirty-two of 6991 patients (3.3%) reported a dream. Four of those also reported awareness and remembered real events that were distinguishable from their dream. Awareness was 19 times more common among patients who after surgery reported a dream [1.7% vs. 0.09%; odds ratio (OR) 18.7; P=0.000007], but memories of dreams did not precede memories of awareness in any of the 232 patients reporting a dream. Unpleasant dreams were significantly more common when thiopentone was used compared with propofol (OR 2.22; P=0.005). Neutral or pleasant dreams were related to lower body mass index, female gender and shorter duration of anaesthesia. We found a statistically significant association between dreams reported after general anaesthesia and awareness, although intraoperative dreams were not an early interpretation of delayed awareness in any case. A typical dreamer in this study is a lean female having a short procedure.

  11. Seven-year retrospective clinical study evaluating efficacy of stainless steel mesh in mandibular fractures.

    Science.gov (United States)

    Chakraborty, Sudip; Ghosh, Samiran; Burman, Richi; Ray, Amit

    2011-10-01

    The use of titanium mesh in communited mandibular fractures has been substantially documented. However, the use of stainless steel mesh for routine fixation in mandibular fractures has not been widely reported. The aim of the present study was to evaluate the efficacy of stainless steel mesh for routine osteosynthesis of mandibular fractures. A total of 252 patients who had been diagnosed with 287 single or multiple mandibular fractures at Guru Nanak Institute of Dental Science and Research from 2002 to 2009 were selected for the present study. Those with condylar fractures and other maxillofacial injuries were excluded from the study. The patients were evaluated preoperatively, intraoperatively, and postoperatively at 1 day, 6 weeks, and 3 and 6 months. The local complications, occlusion (for static function), and chewing (for dynamic function) were evaluated postoperatively. The intraoperative time taken for implant fixation (from site exposure to fixation of the last screw) was 32 minutes. Of the 252 patients, 40 (15.8%) had local complications and 24 patients required implant removal. Of the 252 patients, 82% had bilaterally satisfactory occlusion according to the surgeon at 6 months postoperatively. Discomfort in chewing unilaterally or bilaterally was reported by 17% of the patients. The results of our study have shown that stainless steel mesh has acceptable complication rates and the ability to maintain occlusion and chewing postoperatively compared with the present standards of care of mandibular fractures using miniplates. The lower cost and versatile placement of screws were the principal advantages. However, placement near the mental foramen with an extraoral approach for certain sites is the primary disadvantage. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Delayed vertebral diagnosed L4 pincer vertebral fracture, L2-L3 ruptured vertebral lumbar disc hernia, L5 vertebral wedge fracture - Case report

    OpenAIRE

    Balasa D; Schiopu M; Tunas A; Baz R; Hancu Anca

    2016-01-01

    An association between delayed ruptured lumbar disc hernia, L5 vertebral wedge fracture and posttraumaticL4 pincer vertebral fracture (A2.3-AO clasification) at different levels is a very rare entity. We present the case of a 55 years old male who falled down from a bicycle. 2 months later because of intense and permanent vertebral lumbar and radicular L2 and L3 pain (Visual Scal Autologus of Pain7-8/10) the patient came to the hospital. He was diagnosed with pincer vertebral L4 fracture (A2....

  13. Intraoperative tractography and neuronavigation of the pyramidal tract

    International Nuclear Information System (INIS)

    Nimsky, C.; Ganslandt, O.; Weigel, D.; Keller, B. von; Stadlbauer, A.; Akutsu, H.; Hammen, T.; Buchfelder, M.

    2008-01-01

    Diffusion tensor imaging (DTI) based fiber tracking was applied to visualize the course of the pyramidal tract in the surgical field by microscope-based navigation. In 70 patients with lesions adjacent to the pyramidal tract, DTI data were integrated in a navigational setup. Diffusion data (b=0) were rigidly registered with standard T1-weighted 3-D images. Fiber tracking was performed applying a tensor-deflection algorithm using a multiple volume of interest approach as seed regions for tracking. fMRI data identifying the motor gyrus were applied as selection criteria to define the fibers of interest. After tracking, a 3-D object was generated representing the pyramidal tract. In selected cases, the intraoperative image data (1.5 T intraoperative MRI) were used to update the navigation system. In all patients the pyramidal tract could be visualized in the operative field applying the heads-up display of the operating microscope. In 8 patients (11%) a new or aggravated postoperative paresis could be observed, which was transient in 5 of them; thus, only in 3 patients (4.2%) was there a new permanent neurological deficit. Intraoperative imaging depicted a shifting of the pyramidal tract which amounted up to 15 mm; even the direction of shifting was variable and could not be predicted before surgery, so that mathematical models trying to predict brain shift behaviour are of restricted value only. DTI fiber tracking data can be reliably integrated into navigational systems providing intraoperative visualization of the pyramidal tract. This technique allowed the resection of lesions adjacent to the pyramidal tract with low morbidity. (author)

  14. Intraoperative cell salvage in South Africa: Feasible, beneficial and ...

    African Journals Online (AJOL)

    More than one CS blood unit was available for transfusion in 66% of cases. No additional staff were required to operate the Cell Saver, which was successfully used by medical officers. Conclusions. This study showed that intraoperative CS use is feasible, has potential patient benefit by reducing blood bank blood ...

  15. Parotid tumours: clinical and oncologic outcomes after microscope-assisted parotidectomy with intraoperative nerve monitoring.

    Science.gov (United States)

    Carta, F; Chuchueva, N; Gerosa, C; Sionis, S; Caria, R A; Puxeddu, R

    2017-10-01

    Temporary and permanent facial nerve dysfunctions can be observed after parotidectomy for benign and malignant lesions. Intraoperative nerve monitoring is a recognised tool for the preservation of the nerve, while the efficacy of the operative microscope has been rarely stated. The authors report their experience on 198 consecutive parotidectomies performed on 196 patients with the aid of the operative microscope and intraoperative nerve monitoring. 145 parotidectomies were performed for benign lesions and 53 for malignancies. Thirteen patients treated for benign tumours experienced temporary (11 cases) or permanent facial palsy (2 cases, both of House-Brackmann grade II). Ten patients with malignant tumour presented with preoperative facial nerve weakness that did not improve after treatment. Five and 6 patients with malignant lesion without preoperative facial nerve deficit experienced postoperative temporary and permanent weakness respectively (the sacrifice of a branch of the nerve was decided intraoperatively in 2 cases). Long-term facial nerve weakness after parotidectomy for lesions not directly involving or originating from the facial nerve (n = 185) was 2.7%. Patients treated for benign tumours of the extra facial portion of the gland without inflammatory behaviour (n = 91) had 4.4% facial nerve temporary weakness rate and no permanent palsy. The combined use of the operative microscope and intraoperative nerve monitoring seems to guarantee facial nerve preservation during parotidectomy. © Copyright by Società Italiana di Otorinolaringologia e Chirurgia Cervico-Facciale, Rome, Italy.

  16. Long Term Survivorship of a Severely Notched Femoral Stem after Replacing the Fractured Ceramic head with a Cobalt-Chromium Head.

    Science.gov (United States)

    Panagopoulos, Andreas; Tatani, Irini; Megas, Panagiotis

    2016-01-01

    Although ceramic head fracture occurs infrequently today, in the event of a fracture, the resulting revision surgery can prove very challenging, since the ceramic particles lodge into the surrounding soft tissue and can cause rapid implant failure. A case of long term survivorship of a severed notched femoral stem after replacing the fractured femoral head with a cobalt-chromium one is reported in a 40-year old woman with hip dysplasia who underwent an uncomplicated total hip arthroplasty. The incident of ceramic femoral head fracture occurred 14 months postoperatively without reporting any significant trauma. Intraoperative findings at revision were a multifragmented femoral head and a damaged polyethylene insert along with diffuse metallosis and excessive wear of the cone of the stem. Both the stem and the acetabular component were stable. After removal of ceramic fragments, metallotic tissue excision and careful lavage of the joint, the inlay was replaced by a similar one and a cobalt-chromium femoral head was placed to the existing notched taper of the firmly incorporated stem. At the 13 th year follow up examination, the patient had no pain, used no walking aids, and had normal activity with no signs of wearing or loosening in the plain x-rays. Despite current recommendations of using ceramic femoral heads in cases of fracture or to revise the severely damaged stems we were able to provide a long term survivorship up to 13 years postoperatively of a cobalt-chromium femoral head applied to a severe damaged stem.

  17. Anterior fracture dislocation of the sacroiliac joint: A case report and literature review.

    Science.gov (United States)

    Xiao, Jianlin; Wang, Yang; Zhang, Minglei; Jiang, Rui; Zhu, Tongtong; Liu, Guangyao; Zuo, Jianlin

    2017-08-09

    Publications describing the diagnosis and treatment of anterior dislocation of the sacroiliac joint are scarce. We report the case a 19-year-old female at 8 weeks' gestation who presented with anterior fracture dislocation of the right sacroiliac joint, posterior fracture dislocation of the left sacroiliac joint (crescent fracture), and incomplete abortion resulting from high energy trauma. Orthopedic surgery involved standard anterior sacroiliac joint plating using an ilioinguinal approach combined with a modified Stoppa approach. Three attempts at complete abortion failed. Complete abortion was eventually achieved by dilatation and curettage two weeks after orthopedic surgery. Our findings reveal a need to improve techniques for diagnosis and treatment of anterior fracture dislocation of the sacroiliac joint, so greater attention can be paid to the rapid and effective management of associated comorbidities, and those resulting from the initial trauma.

  18. Isolated Multiple Fragmented Cricoid Fracture Associated with External Blunt Neck Trauma: A Case Report

    International Nuclear Information System (INIS)

    Lee, Byung Hoon; Hwang, Yoon Joon; Kim, Yong Hoon; Seo, Jung Wook; Cho, Hyeon Je; Kim, Yeon Soo

    2010-01-01

    Blunt laryngeal trauma is a relatively uncommon but possibly life-threatening injury. An isolated cricoid fracture associated with blunt trauma is rare. We report a case of an isolated multiple fragmented cricoid cartilage fracture that developed in a 20-year-old man after a blunt neck trauma that occurred during a baseball game and was diagnosed by 64-slice multidetector computed tomography (MDCT)

  19. A Rare Entity: Bilateral First Rib Fractures Accompanying Bilateral Scapular Fractures

    Directory of Open Access Journals (Sweden)

    Gultekin Gulbahar

    2015-01-01

    Full Text Available First rib fractures are scarce due to their well-protected anatomic locations. Bilateral first rib fractures accompanying bilateral scapular fractures are very rare, although they may be together with scapular and clavicular fractures. According to our knowledge, no case of bilateral first rib fractures accompanying bilateral scapular fractures has been reported, so we herein discussed the diagnosis, treatment, and complications of bone fractures due to thoracic trauma in bias of this rare entity.

  20. A Case of Acromioclavicular Joint Dislocation Associated with Coracoid Process Fracture.

    Science.gov (United States)

    Nakamura, Yosuke; Gotoh, Masafumi; Mitsui, Yasuhiro; Shirachi, Isao; Yoshikawa, Eiichiro; Uryu, Takuya; Murakami, Hidetaka; Okawa, Takahiro; Higuchi, Fujio; Shiba, Naoto

    2015-01-01

    Rupture of any two or more parts of the superior shoulder suspensory complex (SSSC) including the distal clavicle, acromion, coracoid process, glenoid cavity of the scapula, acromioclavicular ligament, and coracoclavicular ligament is associated with shoulder girdle instability and is an indication for surgery. Here we report a case of acromioclavicular joint dislocation associated with coracoid process fracture. A 48-year-old man sustained a hard blow to the left shoulder from a fall, and simple radiography detected a coracoid process fracture and acromioclavicular joint dislocation. The injury consisted of a rupture of two parts of the SSSC. For the coracoid process fracture, osteosynthesis was performed using hollow cancellous bone screws. For the acromioclavicular joint dislocation, hook plate fixation and the modified Neviaser's procedure were performed. The bone healed well 5 months after surgery, at which time the screws were removed. At 18 months after initial surgery, the coracoid process fracture had healed with a 10% rate of dislocation on radiography, and the patient currently has no problem performing daily activities, no range of motion limitations, and a Japanese Orthopaedic Association scale score of 93.

  1. Intraoperative Cochlear Implant Device Testing Utilizing an Automated Remote System: A Prospective Pilot Study.

    Science.gov (United States)

    Lohmann, Amanda R; Carlson, Matthew L; Sladen, Douglas P

    2018-03-01

    Intraoperative cochlear implant device testing provides valuable information regarding device integrity, electrode position, and may assist with determining initial stimulation settings. Manual intraoperative device testing during cochlear implantation requires the time and expertise of a trained audiologist. The purpose of the current study is to investigate the feasibility of using automated remote intraoperative cochlear implant reverse telemetry testing as an alternative to standard testing. Prospective pilot study evaluating intraoperative remote automated impedance and Automatic Neural Response Telemetry (AutoNRT) testing in 34 consecutive cochlear implant surgeries using the Intraoperative Remote Assistant (Cochlear Nucleus CR120). In all cases, remote intraoperative device testing was performed by trained operating room staff. A comparison was made to the "gold standard" of manual testing by an experienced cochlear implant audiologist. Electrode position and absence of tip fold-over was confirmed using plain film x-ray. Automated remote reverse telemetry testing was successfully completed in all patients. Intraoperative x-ray demonstrated normal electrode position without tip fold-over. Average impedance values were significantly higher using standard testing versus CR120 remote testing (standard mean 10.7 kΩ, SD 1.2 vs. CR120 mean 7.5 kΩ, SD 0.7, p automated testing with regard to the presence of open or short circuits along the array. There were, however, two cases in which standard testing identified an open circuit, when CR120 testing showed the circuit to be closed. Neural responses were successfully obtained in all patients using both systems. There was no difference in basal electrode responses (standard mean 195.0 μV, SD 14.10 vs. CR120 194.5 μV, SD 14.23; p = 0.7814); however, more favorable (lower μV amplitude) results were obtained with the remote automated system in the apical 10 electrodes (standard 185.4 μV, SD 11.69 vs. CR

  2. transverse patella fracture in a ten year old boy: case report

    African Journals Online (AJOL)

    report a case of a transverse patella fracture in a ten year old boy. He presented with ... fall, he reported that he had pain and swelling which resolved ... radiographs of the patient's right (normal) knee. Figure 1 ... the limb splinted in a back slab.

  3. Coracoid fracture in an adolescent rugby player – Case report and review of the literature

    International Nuclear Information System (INIS)

    Alsey, Karl J.; Mahapatra, Anant N.; Jessop, Julian H.

    2012-01-01

    Coracoid fractures are rare injuries which may be easily missed radiographically. This case report discusses a 14 year old child who sustained a coracoid fracture during a violent tackle whilst playing rugby. The fracture was clearly visible only on the axial view of the shoulder, and was subsequently confirmed by CT scan. This article includes a discussion detailing the anatomy and developmental features of the coracoid process of the scapula, its clinical significance, and radiological assessment of suspected coracoid injury.

  4. Utility of intraoperative diagnostic C-arm angiography for management of high grade subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Zhikui Wei

    2015-06-01

    Full Text Available The accurate and efficient localization of underlying vascular lesions is crucial for prompt and definitive treatment of subarachnoid hemorrhage (SAH. To demonstrate the utility and feasibility of intraoperative C-arm angiography in cerebrovascular emergencies, we report five cases of high grade SAH and/or intracerebral hemorrhage (ICH where intraoperative diagnostic C-arm angiography was safely and effectively utilized. Initial evaluations of all patients included a non-contrast head CT scan, which was followed by urgent decompressive hemicraniectomy as a life-saving measure in the presence of markedly elevated intracranial pressure. Further diagnostic evaluations were performed intraoperatively using a multi-purpose C-arm angiography system. The C-arm angiography findings greatly aided the intraoperative planning and led to definitive treatments in four cases of SAH by elucidating the underlying neurovascular lesions. With this treatment strategy, two of the patients made moderately good recoveries from their SAH and/or ICH with a Glasgow outcome score (GOS of 4. Three of the patients expired despite maximal therapy mostly due to unfavorable presenting grade. These results suggest that C-arm angiography is a reasonable diagnostic and surgical planning tool for selected patients with high grade diffuse SAH who require immediate decompression.

  5. Acute hypotension in a patient undergoing posttraumatic cervical spine fusion with somatosensory and motor-evoked potential monitoring while under total intravenous anesthesia: a case report.

    Science.gov (United States)

    Cann, David F

    2009-02-01

    Hypotension should be vigilantly prevented in patients with spinal cord injury. Recent advances in neurological, intraoperative monitoring techniques have allowed Certified Registered Nurse Anesthetists to assess the effects of spinal cord ischemia and compression as they occur. This case report describes a young, healthy man who sustained a cervical spine fracture and was scheduled for anterior spinal fusion with somatosensory and motor-evoked potential (MEP) monitoring while under total intravenous anesthesia. This patient experienced a brief period of intraoperative hypotension with evidence of abnormal MEPs. A wake-up test was performed, which showed normal functioning, and the case resumed an uneventful course. Although this scenario resulted in no neurological sequelae, the effects of spinal cord ischemia due to hypotension can lead to permanent, devastating motor and sensory damage.

  6. Management of complicated crown-root fracture in central incisors using intentional replantation with 180° rotation: A case report

    Directory of Open Access Journals (Sweden)

    Reyhaneh Faghihian

    2017-01-01

    Full Text Available Introduction: Complicated crown-root fractures are rare and their treatment is complex. Numerous methods such as crown lengthening and orthodontic or surgical extrusion have been described for the treatment of crown-root fracture. The aim of this study was to report managing complicated crown-root fracture using intentional replantation with 180° rotation. Case report: This case report demonstrates successful management of complicated crown-root fracture in central incisor of a 10-year-old boy using intentional replantation with 180° rotation. Discussion: At 18-month follow-up, the replanted tooth revealed normal function with no obvious resorption.

  7. Metachronous bilateral subtrochanteric fracture of femur in an osteopetrotic bone: A case report with technical note.

    Science.gov (United States)

    Kumar, Dharmendra; Jain, Vijay Kumar; Lal, Hitesh; Arya, Rajinder Kumar; Sinha, Skand

    2012-12-01

    Osteopetrosis is a rare inherited skeletal disorder characterized by increased density. The increased fragility of such dense bone results in a greater incidence of fractures, especially around hip and proximal femur. The surgical treatment of such fractures is difficult due to hard but brittle structure of bone. Herein we report a case of bilateral subtrochanteric fracture in an osteopetrotic patient. It was fixed using a dynamic hip screw with plate.

  8. Selective Use of Sentinel Lymph Node Surgery in Patients Undergoing Prophylactic Mastectomy Using Intraoperative Pathology.

    Science.gov (United States)

    Murphy, Brittany L; Glasgow, Amy E; Keeney, Gary L; Habermann, Elizabeth B; Boughey, Judy C

    2017-10-01

    Routine sentinel lymph node (SLN) surgery during prophylactic mastectomy (PM) is unnecessary, because most PMs do not contain cancer. Our institution utilizes intraoperative pathology to guide the surgical decision for resection of SLNs in PM. The purpose of this study was to review the effectiveness of this approach. We identified all women aged ≥18 years who underwent bilateral PM (BPM) or contralateral PM (CPM) at our institution from January 2008 to July 2016. We evaluated the frequency of SLN resection and rate of occult breast cancer (DCIS or invasive disease) in the PM. We used the following definitions: over-treatment-SLN surgery in patients without cancer; under-treatment-no SLN surgery in patients with cancer; appropriate treatment-no SLN in patients without cancer or SLN surgery in patients with cancer. PM was performed on 1900 breasts: 1410 (74.2%) CPMs and 490 (25.8%) BPMs. Cancer was identified in 58 (3.0%) cases (32 invasive disease and 26 DCIS) and concurrent SLN surgery was performed in 44 (75.9%) of those cases. Overall, SLN surgery guided by intraoperative pathology resulted in appropriate treatment of 1787 (94.1%) cases: 1319 (93.5%) CPMs and 468 (95.5%) BPMs, by avoiding SLN in 1743/1842 cases without cancer (94.6%), and performing SLN surgery in 44/58 cases with cancer (75.9%). Use of intraoperative pathology to direct SLN surgery in patients undergoing PM minimizes over-treatment from routine SLN in PM and minimizes under-treatment from avoiding SLN in PM, demonstrating the value of intraoperative pathology in this era of focus on appropriateness of care.

  9. Successful Management of Phaeochromocytoma using Preoperative Oral Labetalol and Intraoperative Magnesium Sulphate; Report of four cases

    Directory of Open Access Journals (Sweden)

    Sanath Kumar B. S.

    2014-05-01

    Full Text Available Phaeochromocytoma is a rare neuroendocrine catecholamine-secreting tumour. This type of tumour poses multidimensional anaesthetic challenges as it has an unpredictable clinical course during surgical resection. The alpha-blocking agent phenoxybenzamine remained the mainstay in preoperative preparation before the introduction of beta-blocking agents. We report four cases operated between 2009–2012 at Sultan Qaboos University Hospital, Muscat, Oman. The cases were prepared with oral labetalol, as the alpha-blocking drug phenoxybenzamine was not immediately available. Responses to simulated stress were tested in the theatre before surgery. Anaesthesia was induced under invasive arterial pressure monitoring and magnesium sulphate infusion. Rare intraoperative surges in blood pressure during tumour manipulation were treated with sodium nitroprusside infusions and phentolamine boluses. All of the patients had an uneventful postoperative recovery. Preoperative treatment with labetalol has rarely been reported and can be considered as a potential therapeutic option with optimal patient monitoring if phenoxybenzamine is unavailable.

  10. Transstyloid, transscaphoid, transcapitate fracture: a variant of scaphocapitate fractures.

    LENUS (Irish Health Repository)

    Burke, Neil G

    2014-01-01

    Transstyloid, transscaphoid, transcapitate fractures are uncommon. We report the case of a 28-year-old man who sustained this fracture following direct trauma. The patient was successfully treated by open reduction internal fixation of the scaphoid and proximal capitate fragment, with a good clinical outcome at 1-year follow-up. This pattern is a new variant of scaphocapitate fracture as involves a fracture of the radial styloid as well.

  11. A Limb-Threatening Long Arterial Dissection Caused by Humerus Neck Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Kurnaz R

    2018-03-01

    Full Text Available Proximal humerus fracture is a common arm trauma and rarely occurs with vascular injury which however is a serious complication. In this case report, we present a long segment dissection of the axillary and brachial arteries as a rare complication due to fragmented proximal humerus fracture and shoulder dislocation. An 80-year old female patient was seen at the emergency department. Radiograph examination has revealed a fragmented proximal humerus fracture besides dislocation of the head of humerus towards the axillary area. On vascular examination, acute arterial occlusion such as absence of radial and ulnar pulses were observed in her left hand. The patient was immediately taken to the operating room. The dissection included the entire segment approximately 20cm between the distal subclavian artery and the distal brachial artery. This injured segment was removed and a 6mm Polytetrafluroethylene (PTFE graft with rings was interpositoned between subclavian and brachial arteries. This case is a rarity because of such a significant complication after a small injury. Axillary artery injuries caused by humeral neck fractures are rare but should not be missed by the physician.

  12. Prevention of avascular necrosis in displaced talar neck fractures by hyperbaric oxygenation therapy: A dual case report

    Directory of Open Access Journals (Sweden)

    Mei-Dan O

    2008-01-01

    Full Text Available Talar neck fractures are a rare injury that account for less then 2% of all foot fractures. Displaced fractures are associated with an exceedingly high rate of avascular necrosis (AVN. The incidence of AVN following Hawkins Type 3 fractures of the talar neck may approach 100%, particularly if diagnosis and reduction are delayed. Severe cases may present as pain and disability of the ankle and the subtalar joints due to a talar dome collapse, resulting in degenerative changes that usually require hind foot arthrodesis. We present two cases of traumatic displaced talar neck fractures which were treated surgically more than 2 weeks following injury due to a delay in diagnosis. Both patients underwent hyperbaric oxygen therapy (HBOT after the operation and neither resulted in AVN of the talus in a three-year follow-up. We suggest that this favorable result may be due to the beneficial effects of HBOT.

  13. Perception and reality in a case of suspected cervical fracture.

    Science.gov (United States)

    Ridolfi, Marcello; Antinolfi, Gabriele; Genova, Vincenzo; Scutellari, Pier Nuccio; Campioni, Paolo; Mannella, Paolo

    2005-01-01

    The case of a 36-year-old female, who following a road accident, had a cervical whiplash, is discussed. A radiographic examination of the affected region was performed at the Emergency Department. It showed a transverse radiolucent line at the basal odontoid process of the axis. A definitive interpretation was not possible and fracture of the odontoid process of the axis was suggested as differential diagnosis. On coronal CT reconstruction the presence of this fracture was ruled out. The line seen on the film was actually the product of a psychophysiologic visual illusion known as "Mach band". The use of conventional radiography correlated with digital CT images shows that the practical application of Mach band theory allows a better differentiation between normal and pathologic anatomy.

  14. Atrophy of the brachialis muscle after a displaced clavicle fracture in an Ironman triathlete: case report

    Directory of Open Access Journals (Sweden)

    Knechtle Patrizia

    2011-10-01

    Full Text Available Abstract Clavicle fractures are frequent injuries in athletes and midshaft clavicle fractures in particular are well-known injuries in Ironman triathletes. In 2000, Auzou et al. described the mechanism leading to an isolated truncular paralysis of the musculocutaneous nerve after a shoulder trauma. It is well-known that nerve palsies can lead to an atrophy of the associated muscle if they persist for months or even longer. In this case report we describe a new case of an Ironman triathlete suffering from a persistent isolated atrophy of the brachialis muscle. The atrophy occurred following a displaced midshaft clavicle fracture acquiring while falling off his bike after hitting a duck during a competition.

  15. Recurrent hydatosis at the site of non-union humerus fracture

    Directory of Open Access Journals (Sweden)

    Mohsen Nourbakhsh

    2012-01-01

    Full Text Available Hydatid disease is still endemic in several regions of the world and is caused by two species of tapeworms, Echinococcus granulosus and Echinococcus alveolaris. It primary involves liver and lung, and bone involvement is relatively rare (0.2-4%, where it is most commonly seen in the spine. The skeletal involvement is usually due to secondary extension such as hematogenous spread. The disease has usually a silent manifestation until a complication exists; so, many cases are diagnosed intraoperatively. Treatment of hydatid disease because of its bone involvement and spillage of fluid with subsequent contamination seeding is difficult, so it has a high mortality rate and many cases will recur. Therefore, we can prevent these occurrences if we treat hydatid disease completely and in the primary stage. Adjuvant medical treatment, if the diagnosis is known, prevents systemic spread and recurrence. Here, we present a primary recurrent hydatosis at the site of non-union humerus fracture. We have pointed out osseous hydatosis as one of the important differential diagnoses in destructive bone lesions and the necessity of its radical resection.

  16. Atypical femoral neck stress fracture in a marathon runner: a case report and literature review.

    LENUS (Irish Health Repository)

    2012-02-01

    BACKGROUND: Femoral neck stress fractures are relatively rare and may present as sports-related injuries. The presentation is variable, and prompt diagnosis facilitates the earliest return to pre-morbid functional activity levels. Delayed detection may precipitate femoral non-union or avascular necrosis, resulting in long-term functional deficit. AIMS: We present the case of a basicervical femoral neck stress fracture occurring in a 23-year-old marathon runner. The pathophysiology and practical management issues related to this unusual injury pattern are discussed. CONCLUSION: The growing interest in amateur athletic activities should raise the index of suspicion for stress fractures of the femoral neck in healthy adults with atypical hip pain. Increased levels of patient education and physician awareness can reduce the incidence of long-term morbidity in cases of this unusual sports-related injury.

  17. Clinical and functional outcome of open primary repair of triangular fibrocartilage complex tears associated with distal radius fractures.

    Science.gov (United States)

    Johandi, Faisal; Sechachalam, Sreedharan

    2017-01-01

    We evaluate the clinical and functional outcome of open primary repair of acute TFCC tears in distal radius fracture, when there is gross intraoperative distal radioulnar joint (DRUJ) instability after fixation of the distal radius, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed. A retrospective review of our institution's distal radius fracture database over a 4-year period (January 2010 to December 2013). A total of 12 (1.38%) out of 3379 patients had an open TFCC repair in the same setting as fixation of distal radius. Assessment of outcome involved the analysis of objective and subjective clinical and functional outcomes. All patient regained Activities of Daily Living (ADL) independence; eleven out of 12 patients (91.7%) returned to pre-injury function and 8 out of 11 patients (72.7%) returned to their jobs. DRUJ stability was preserved in 10 patients (83.3%) with 10 patients (83.3%) having grip strength of at least 50%, compared to the uninjured hand, and 7 (58.3%) with grip strength of more than or equal to 75%. Complications of surgery identified can be classified into 4 broad categories: infection, neurological complications, persistent DRUJ instability and prolonged pain. The authors believe a primary open repair of the TFCC should be considered when patients present with instability during intra-operative DRUJ ballottement test after distal radius fixation, in the absence of an ulnar styloid fracture or when the ulnar fracture fragment is too small to be fixed.

  18. Minimally invasive plate osteosynthesis for humeral shaft fractures: are results reproducible?

    Science.gov (United States)

    Concha, Juan M; Sandoval, Alejandro; Streubel, Philipp N

    2010-12-01

    Minimally invasive plate osteosynthesis (MIPO) has been advocated as a safe approach to humeral shaft fracture management. We evaluated the reproducibility of this technique in a regional hospital. Thirty-five patients underwent MIPO of humerus shaft fractures. Fifteen patients had an open fracture, six a preoperative radial nerve palsy, and nine a concomitant thoracic, musculoskeletal or vascular injury. At an average 12-month follow-up, 91% of fractures healed after a mean of 12 weeks (range, 8-16). Two infections occurred. Final alignment averaged 4° of varus (range, 5° of valgus to 20° of varus). Active elbow ROM averaged 114° (range, 60-135°) and was less than 100° in nine elbows. Five of six preoperative radial nerve injuries recovered spontaneously. Healing and infection rates in this study are consistent with those reported in the literature. Lower elbow ROM and higher fracture angulation at healing were nevertheless found. MIPO is technically demanding and requires adequate intraoperative imaging and surgical experience in order to obtain adequate fracture alignment. Brachialis muscle scarring and inadequate postoperative rehabilitation may be involved in limited elbow range of motion.

  19. [Selective intraoperative cholangiography in laparoscopic cholecystectomy].

    Science.gov (United States)

    Pickuth, D; Leutloff, U

    1995-01-01

    Routine use of intraoperative cholangiography during laparoscopic cholecystectomy is still widely advocated and standard in many departments; however, it is controversial. We have developed a new diagnostic strategy for the detection of bile duct stones. The concept is based on an ultrasound examination and on screening for the presence of six risk indicators of choledocholithiasis. A total of 120 patients undergoing laparoscopic cholecystectomy were prospectively screened for the presence of these six risk indicators: history of jaundice, history of pancreatitis, hyperbilirubinemia, hyperamylasemia, dilated bile duct, and unclear ultrasound findings. The sensitivity of ultrasound and intraoperative cholangiography in diagnosing bile duct stones was also evaluated. For the detection of bile duct stones, the sensitivity was 77% for ultrasound and 100% for intraoperative cholangiography. Twenty percent of all patients had at least one risk indicator. The presence of a risk indicator correlated significantly with the presence of choledocholithiasis (P concept, we would have avoided 80% of intraoperative cholangiographies without missing a stone in the bile duct. This study lends further support to the view that routine use of intraoperative cholangiography is not necessary.

  20. Intraoperative Cerebral Glioma Characterization with Contrast Enhanced Ultrasound

    Directory of Open Access Journals (Sweden)

    Francesco Prada

    2014-01-01

    Full Text Available Background. Contrast enhanced ultrasound (CEUS is a dynamic and continuous modality providing real-time view of vascularization and flow distribution patterns of different organs and tumors. Nevertheless its intraoperative use for brain tumors visualization has been performed few times, and a thorough characterization of cerebral glioma had never been performed before. Aim. To perform the first characterization of cerebral glioma using CEUS and to possibly achieve an intraoperative differentiation of different gliomas. Methods. We performed CEUS in an off-label setting in 69 patients undergoing surgery for cerebral glioma. An intraoperative qualitative analysis was performed comparing iCEUS with B-mode imaging. A postprocedural semiquantitative analysis was then performed for each case, according to EFSUMB criteria. Results were related to histopathology. Results. We observed different CE patterns: LGG show a mild, dotted CE with diffuse appearance and slower, delayed arterial and venous phase. HGG have a high CE with a more nodular, nonhomogeneous appearance and fast perfusion patterns. Conclusion. Our study characterizes for the first time human brain glioma with CEUS, providing further insight regarding these tumors’ biology. CEUS is a fast, safe, dynamic, real-time, and economic tool that might be helpful during surgery in differentiating malignant and benign gliomas and refining surgical strategy.

  1. Validation of a New Method to Automatically Select Cases With Intraoperative Red Blood Cell Transfusion for Audit.

    Science.gov (United States)

    Dexter, Franklin; Epstein, Richard H; Ledolter, Johannes; Dasovich, Susan M; Herman, Jay H; Maga, Joni M; Schwenk, Eric S

    2018-05-01

    Hospitals review allogeneic red blood cell (RBC) transfusions for appropriateness. Audit criteria have been published that apply to 5 common procedures. We expanded on this work to study the management decision of selecting which cases involving transfusion of at least 1 RBC unit to audit (review) among all surgical procedures, including those previously studied. This retrospective, observational study included 400,000 cases among 1891 different procedures over an 11-year period. There were 12,616 cases with RBC transfusion. We studied the proportions of cases that would be audited based on criteria of nadir hemoglobin (Hb) greater than the hospital's selected transfusion threshold, or absent Hb or missing estimated blood loss (EBL) among procedures with median EBL 50%) that would be audited and most cases (>50%) with transfusion were among procedures with median EBL 9 g/dL, the procedure's median EBL was 9 g/dL and median EBL for the procedure ≥500 mL. An automated process to select cases for audit of intraoperative transfusion of RBC needs to consider the median EBL of the procedure, whether the nadir Hb is below the hospital's Hb transfusion threshold for surgical cases, and the absence of either a Hb or entry of the EBL for the case. This conclusion applies to all surgical cases and procedures.

  2. Physical fracture properties (fracture surfaces as information sources; crackgrowth and fracture mechanisms; exemples of cracks)

    International Nuclear Information System (INIS)

    Meny, Lucienne.

    1979-06-01

    Fracture surfaces are considered as a useful source of informations: an introduction to fractography is presented; the fracture surface may be observed through X ray microanalysis, and other physical methods such as Auger electron spectroscopy or secundary ion emission. The mechanisms of macroscopic and microscopic crackgrowth and fracture are described, in the case of unstable fracture (cleavage, ductile with shear, intergranular brittleness) and of progressive crack propagation (creep, fatigue). Exemples of cracks are presented in the last chapter [fr

  3. Stress fracture of hamate's hook: case report with emphasis to the imaging findings

    International Nuclear Information System (INIS)

    Carvalho, Leonardo Fontenelle de; Vianna, Evandro Miguelote; Domingues, Romulo; Domingues, Romeu Cortes; Metsavaht, Leonardo

    2007-01-01

    Stress fractures of the hook of the hamate are related to sports that use devices such as golf clubs, rackets and baseball bats. Because usually there is no history of obvious trauma, the diagnosis necessitates better knowledge of the lesion and high index of suspicion. The authors report a case of stress fracture of the hook of the hamate in a golf player with diagnosis and follow-up done with magnetic resonance and multislice computer tomography. (author)

  4. Chance Fracture Secondary to a Healed Kyphotic Compression Osteoporotic Fracture

    Directory of Open Access Journals (Sweden)

    Teh KK

    2009-11-01

    Full Text Available Chance fracture is an unstable vertebral fracture, which usually results from a high velocity injury. An elderly lady with a previously healed osteoporotic fracture of the T12 and L1 vertebra which resulted in a severe kyphotic deformity subsequently sustained a Chance fracture of the adjacent L2 vertebrae after a minor fall. The previously fracture left her with a deformity which resulted in significant sagittal imbalance therefore predisposing her to this fracture. This case highlights the importance of aggressive treatment of osteoporotic fractures in order to prevent significant sagittal imbalance from resultant (i.e. kyphotic deformity.

  5. Orbital wall fractures

    International Nuclear Information System (INIS)

    Iinuma, Toshitaka; Ishio, Ken-ichirou; Yoshinami, Hiroyoshi; Kuriyama, Jun-ichi; Hirota, Yoshiharu.

    1993-01-01

    A total of 59 cases of mild facial fractures (simple orbital wall fractures, 34 cases, other facial fractures, 25 cases) with the clinical suspects of orbital wall fractures were evaluated both by conventional views (Waters' and Caldwell views) and coronal CT scans. Conventional views were obtained, as an average, after 4 days and CT after 7 days of injuries. Both the medial wall and the floor were evaluated at two sites, i.e., anterior and posterior. The ethmoid-maxillary plate was also included in the study. The degree of fractures was classified as, no fractures, fractures of discontinuity, dislocation and fragmentation. The coronal CT images in bone window condition was used as reference and the findings were compared between conventional views and CT. The correct diagnosis was obtained as follows: orbital floor (anterior, 78%, posterior, 73%), medial orbital wall (anterior, 72%, posterior, 72%) and ethmoid-maxillary plate (64%). The false positive diagnosis was as follows: orbital floor (anterior only, 13%), medial orbital wall (anterior only, 7%) and ethmoid-maxillary plate (11%). The false negative diagnosis was as follows: orbital floor (anterior, 9%, posterior, 10%), medial orbital wall (anterior, 21%, posterior, 28%) and ethmoid-maxillary plate (21%). The results were compared with those of others in the past. (author)

  6. A COMPARATIVE STUDY OF PROXIMAL FEMUR LOCKING COMPRESSION PLATE VERSUS PROXIMAL FEMORAL NAILING IN THE MANAGEMENT OF COMMINUTED TROCHANTERIC AND SUBTROCHANTERIC FRACTURE

    Directory of Open Access Journals (Sweden)

    Satish Koti

    2016-11-01

    Full Text Available BACKGROUND Fractures of proximal femur and hip are relatively common injuries in elderly individuals constituting 11.6% of total fractures. The latest implant for management of intertrochanteric fracture is Proximal Femoral Locking Compression Plate (PF-LCP. In this study, we compare the clinical outcome of fractures treated by proximal femoral nail with that of proximal femur locking compression plate. MATERIALS AND METHODS The present study consists of 24 elderly patients of peritrochanteric factures of femur satisfying the inclusion criteria who were treated with PF-LCP or PFN in Department of Orthopaedics, S.V.R.R.G.G.H, Tirupati, during a period between December 2013 to October 2015. RESULTS 24 cases were treated with PF-LCP or PFN in a randomised pattern who satisfied inclusion criteria. Intraoperative complication were found to be more with PF-LCP in contrast to PFN. Postoperative rehabilitation was easier with PFN though not statistically significant functional and anatomical outcomes were found to be better with PFN. CONCLUSION Both PFN and PF-LCP have good effectiveness in the treatment of intertrochanteric fractures with the lateral unsubstantial femoral wall in the elderly patients. Each has its own advantages and disadvantages. Further studies with large number of patients and long-term follow up is needed to determine the optimal implant for the internal fixation of comminuted pertrochanteric femoral fractures.

  7. Early treatment of simphysis mandible fracture in children 12 years old using Erich arch bar (case report

    Directory of Open Access Journals (Sweden)

    Syahril Samad

    2016-06-01

    Full Text Available Incidence rate of symphysis mandible fracture in children was about 15 – 20%. Boys are effected twice as frequently as girls. The pattern of craniomaxillofacial fractures seen in children varies with evolving skeletal anatomy and socioenvironmental factors. The treatment of pediatric maxillofacial fractures is due to physiological, developmental, and anatomical characteristic of children. Management of pediatric mandible fracture by anatomic reduction is combine with stabilization adequate to maintain it until bone union has occured. This case report is aimed to explain about the management of simphysis mandible fracture in pediatric using erich arch bar. A 12 years old boy has fracture in mandible due to accident with mechanisme the chin hit the touching motorcyle tank. Clinically, was a deformity at the anterior of mandible and malocclusion has occured. Patient also complaint a  pain with swelling and bleeding at the regio of fracture and lip. Suturing was done  in wound area intra and extra oral, followed by application of arch bar in maxilla and mandible. Control at the third day was found a vague fracture line in panoramic radiograph. Management of emergency trauma in oral and maxillofacial surgery was based on principle of ATLS was done in this case. Following treatment was application of erich arch bar for mobility reducing the fracture of mandible symphisis. Management of mandibular symphisis fracture in 12 years old children with full eruption of teeth has been given a good healing  due to the teeth  was act to develop retention and stabilize the erich arch bar. Management of pediatric simphysis mandible fracture for 12 years old children with full eruption of teeth using erich bar revealed a healed fracture.

  8. A Review of Periprosthetic Femoral Fractures Associated With Total Hip Arthroplasty

    Science.gov (United States)

    Marsland, Daniel; Mears, Simon C.

    2012-01-01

    Periprosthetic fractures of the femur in association with total hip arthroplasty are increasingly common and often difficult to treat. Patients with periprosthetic fractures are typically elderly and frail and have osteoporosis. No clear consensus exists regarding the optimal management strategy because there is limited high-quality research. The Vancouver classification facilitates treatment decisions. In the presence of a stable prosthesis (type-B1 and -C fractures), most authors recommend surgical stabilization of the fracture with plates, strut grafts, or a combination thereof. In up to 20% of apparent Vancouver type-B1 fractures, the femoral stem is loose, which may explain the high failure rates associated with open reduction and internal fixation. Some authors recommend routine opening and dislocation of the hip to perform an intraoperative stem stability test to rule out a loose component. Advances in plating techniques and technology are improving the outcomes for these fractures. For fractures around a loose femoral prosthesis (types B2 and 3), revision using an extensively porous-coated uncemented long stem, with or without additional fracture fixation, appears to offer the most reliable outcome. Cement-in-cement revision using a long-stem prosthesis is feasible in elderly patients with a well-fixed cement mantle. It is essential to treat the osteoporosis to help fracture healing and to prevent further fractures. We provide an overview of the causes, classification, and management of periprosthetic femoral fractures around a total hip arthroplasty based on the current best available evidence. PMID:23569704

  9. [18F]FDG PET accurately differentiates infected and non-infected non-unions after fracture fixation

    International Nuclear Information System (INIS)

    Wenter, Vera; Albert, Nathalie L.; Brendel, Matthias; Fendler, Wolfgang P.; Bartenstein, Peter; Cyran, Clemens C.; Friederichs, Jan; Mueller, Jan-Philipp; Militz, Matthias; Hungerer, Sven; Hacker, Marcus

    2017-01-01

    Complete fracture healing is crucial for good patient outcomes. A major complication in the treatment of fractures is non-union. The pathogenesis of non-unions is not always clear, although implant-associated infections play a significant role, especially after surgical treatment of open fractures. We aimed to evaluate the value of [ 18 F]FDG PET in suspected infections of non-union fractures. We retrospectively evaluated 35 consecutive patients seen between 2000 and 2015 with suspected infection of non-union fractures, treated at a level I trauma center. The patients underwent either [ 18 F]FDG PET/CT (N = 24), [ 18 F]FDG PET (N = 11) plus additional CT (N = 8), or conventional X-ray (N = 3). Imaging findings were correlated with final diagnosis based on intraoperative culture or follow-up. In 13 of 35 patients (37 %), infection was proven by either positive intraoperative tissue culture (N = 12) or positive follow-up (N = 1). [ 18 F]FDG PET revealed 11 true-positive, 19 true-negative, three false-positive, and two false-negative results, indicating sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 85 %, 86 %, 79 %, 90 %, and 86 %, respectively. The SUV max was 6.4 ± 2.7 in the clinically infected group and 3.0 ± 1.7 in the clinically non-infected group (p <0.01). The SUV ratio was 5.3 ± 3.3 in the clinically infected group and 2.6 ± 1.5 in the clinically non-infected group (p <0.01). [ 18 F]FDG PET differentiates infected from non-infected non-unions with high accuracy in patients with suspected infections of non-union fractures, for whom other clinical findings were inconclusive for a local infection. [ 18 F]FDG PET should be considered for therapeutic management of non-unions. (orig.)

  10. Treatment of a horizontal root-fractured tooth with decoronation procedure: case report

    Directory of Open Access Journals (Sweden)

    Selen Esin Yoldaş

    2016-05-01

    Full Text Available INTRODUCTION: Early loss of permanent anterior teeth due to trauma can cause esthetic and functional problems for young patients. In such cases, replacement of the missing tooth with traditional approaches is possible; however such approaches will reduce the chance of the patient to receive an esthetic and consistent treatment in the future. CASE REPORT: A 12-year-old male patient referred to our clinic with a history of trauma. Complicated crown fracture in tooth no.11 and horizontal root fracture in tooth no. 21 was detected. Following root canal treatment, tooth no. 11 was restored with a fiber post and a strip crown. To avoid alveolar bone loss due to early tooth extraction, decoronation procedure, an alternative approach, was applied to tooth no. 21. This procedure consisted of leaving the root fragment inside the alveolar socket following the removal of the crown. For the rehabilitation of the missing crown, a partial removable prosthesis was implemented. The patient was recalled in 6., 12. and 18. months. Within the follow-up period, no reduction in the alveolar bone level was seen. No sign of infection was evident. The remaining root fragment kept on resorbing. Tooth no. 11 remained symptom-free as well. The patient is still being followed. CONCLUSION: Decoronation is essentially a treatment choice for preventing alveolar bone loss in ankylosed teeth considered for extraction. In this case report, decoronation was shown to be a suitable alternative also for a fractured, non-ankylosed tooth.

  11. Clinic research on the treatment for humeral shaft fracture with minimal invasive plate osteosynthesis: a retrospective study of 128 cases.

    Science.gov (United States)

    Chen, H; Hu, X; Yang, G; Xiang, M

    2017-04-01

    Minimal invasive plate osteosynthesis (MIPO) is one of the most important techniques in the treatment for humeral shaft fractures. This study was performed to evaluate the efficacy of MIPO technique for the treatment for humeral shaft fractures. We retrospectively evaluated 128 cases with humeral shaft fractures that were treated with MIPO technique from March 2005 to August 2008. All the patients were followed up by routine radiological imaging and clinical examinations. Constant-Murley score and HSS elbow joint score were used to evaluate the treatment outcome. The average duration of the surgery was 60 min (range 40-95 min) without blood transfusion. All fractures healed without infection. All cases recovered carrying angle except four cases with 10°-15° cubitus varus. After the average follow-up of 23 (13-38) months, satisfactory function was achieved according to Constant-Murley score and HSS elbow joint score. Constant-Murley score was 80 on average (range 68-91). According to HSS elbow joint score, there were 123 cases of excellent clinical outcome and five cases of effective outcome. It seems to be a safe and effective method for managing humeral shaft fractures with MIPO technique.

  12. Negative magnetic resonance imaging in three cases of anterior tibial cortex stress fractures

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ralph; Moghal, M.; Newton, J.L.; Jones, N. [Oxford University Hospitals NHS Foundation Trust, Department of Sport and Exercise Medicine, Nuffield Orthopaedic Centre, Oxford (United Kingdom); Teh, J. [Oxford University Hospitals NHS Foundation Trust, Department of Radiology, Nuffield Orthopaedic Centre Oxford, Oxford (United Kingdom)

    2017-12-15

    Anterior mid-tibial cortex stress fractures (ATCSF) are uncommon and notoriously challenging to treat. They are termed high risk due to their predilection to prolonged recovery, nonunion and complete fracture. Early diagnosis is essential to avoid progression and reduce fracture complications. Imaging plays a key role in confirming the diagnosis. Magnetic resonance imaging (MRI) is accepted as the gold standard modality due to its high accuracy and nonionizing properties. This report describes three cases of ATCSFs in recreational athletes who had positive radiographic findings with no significant MRI changes. Two athletes had multiple striations within their tibias. Despite the radiographic findings, their severity of symptoms were low with mild or no tenderness on examination. Clinicians should be mindful that the ATCSFs may not present with typical acute stress fracture symptoms. We recommend that plain radiographs should be used as the first line investigation when suspecting ATCSFs. Clinicians should be aware that despite MRI being considered the gold standard imaging modality, we report three cases where the MRI was unremarkable, whilst radiographs and computed tomography confirmed the diagnosis. We urge clinicians to continue to use radiographs as the first line imaging modality for ATCSFs and not to directly rely on MRI. Those who opt directly for MRI may be falsely reassured causing a delay in diagnosis. (orig.)

  13. Negative magnetic resonance imaging in three cases of anterior tibial cortex stress fractures

    International Nuclear Information System (INIS)

    Smith, Ralph; Moghal, M.; Newton, J.L.; Jones, N.; Teh, J.

    2017-01-01

    Anterior mid-tibial cortex stress fractures (ATCSF) are uncommon and notoriously challenging to treat. They are termed high risk due to their predilection to prolonged recovery, nonunion and complete fracture. Early diagnosis is essential to avoid progression and reduce fracture complications. Imaging plays a key role in confirming the diagnosis. Magnetic resonance imaging (MRI) is accepted as the gold standard modality due to its high accuracy and nonionizing properties. This report describes three cases of ATCSFs in recreational athletes who had positive radiographic findings with no significant MRI changes. Two athletes had multiple striations within their tibias. Despite the radiographic findings, their severity of symptoms were low with mild or no tenderness on examination. Clinicians should be mindful that the ATCSFs may not present with typical acute stress fracture symptoms. We recommend that plain radiographs should be used as the first line investigation when suspecting ATCSFs. Clinicians should be aware that despite MRI being considered the gold standard imaging modality, we report three cases where the MRI was unremarkable, whilst radiographs and computed tomography confirmed the diagnosis. We urge clinicians to continue to use radiographs as the first line imaging modality for ATCSFs and not to directly rely on MRI. Those who opt directly for MRI may be falsely reassured causing a delay in diagnosis. (orig.)

  14. Intraoperative radiotherapy in breast cancer: literature review

    International Nuclear Information System (INIS)

    Alfaro Hidalgo, Sabrina A.

    2013-01-01

    A literature review was performed on intraoperative radiotherapy of breast cancer. The strength and attractiveness is established of techniques of partial irradiation in the treatment of breast cancer. The benefit is originated to restrict the area immediate of radiotherapy to the tumor bed or quadrant index and identifying the benefit of being applied during the radiotherapy while surgical lumpectomy. The impact of local recurrence has been established using intraoperative radiotherapy. The advantages of intraoperative radiotherapy was compared in the management of the conservative surgery in early stages of breast cancer with external radiotherapy. Different methods of intraoperative radiotherapy have been compared and individual impact on local recurrence ranges. Intraoperative radiotherapy has had many advantages: radiobiological, technical, clinical, psychological and economical in the handling of conservative surgery in early stages of breast cancer, compared with external radiotherapy [es

  15. Conservative treatment of Malgaigne fracture in young female - case report

    Directory of Open Access Journals (Sweden)

    Vukašinović Zoran

    2013-01-01

    Full Text Available Introduction. Pelvic ring injuries usually result from high­energy trauma, and cranial and abdominal multiple injuries are frequently present. Malgaigne fracture is referred to pelvic ring disruption at two sites, and is often treated surgically for its instability. We present a case of nonoperative treatment of Malgaigne pelvic fracture. Case Outline. A 17­year­old girl sustained a Malgaigne fracture falling off a horse. After ruling out urgent multiple trauma in local hospital, she was then transferred to Pediatric Orthopedic and Trauma Service at the Institute of Orthopedic Surgery «Banjica» Belgrade, with provisional cutaneous traction of 2 kg applied to her right leg. After the status evaluation, the supracondylar femoral traction was applied for three months, combined with pelvic cradle for first 73 days. Weight of traction was gradually adjusted according to x­ray check­up, ranging from 1­16 kg (1/4 of body weight. Antibiotic prophylaxis was administered for 10 days, and thromboprophylaxis for two months. After the removal of traction, physical therapy was applied and the patient achieved full weight bearing four months after the injury. Treatment outcome was a symmetric and stable pelvic ring, equal leg length, full range of motion in both hip joints and normal walking. Conclusion. Traction therapy, combined with gravitational suspension in pelvic cradle, resulted in excellent clinical result. Although significantly longer and more loaded than usual, normal weight bearing and walking were promptly achieved using intensive physical therapy. [Projekat Ministarstva nauke Republike Srbije, br. III 41004

  16. [Injury to the Scapholunate Ligament in Distal Radius Fractures: Peri-Operative Diagnosis and Treatment Results].

    Science.gov (United States)

    Gajdoš, R; Pilný, J; Pokorná, A

    2016-01-01

    PURPOSE OF THE STUDY Injury to the scapholunate ligament is frequently associated with a fracture of the distal radius. At present neither a unified concept of treatment nor a standard method of diagnosis in these concomitant injuries is available. The aim of the study was to evaluate a group of surgically treated patients with distal radius fractures in order to assess a contribution of combined conventional X-ray and intra-operative fluoroscopic examinations to the diagnosis of associated lesions and to compare short-term functional outcomes of sugically treated patients with those of patients treated conservatively. MATERIAL AND METHODS A group of patients undergoiong surgery for distal radius fractures using plate osteosynthesis was evaluated retrospectively. The peri-operative diagnosis of associated injury to the scapholunate ligament was based on pre-operative standard X-ray views and intra-operative fluoroscopy. The latter consisted of images of maximum radial and ulnar deviation as well as an image of the forearm in traction exerted manually along the long axis. All views were in postero-anterior projection. Results were read directly on the monitor of a fluoroscopic device after its calibration or were obtained by comparing the thickness of an attached Kirschner wire with the distance to be measured. Subsequently, pixels were converted to millimetres. When a scapholunate ligament injury was found and confirmed by examination of the contralateral wrist, the finding was verified by open reduction or arthroscopy. Both static and dynamic instabilities were treated together with the distal radius fracture at one-stage surgery. After surgery, the patients without ligament injury had the wrist immobilised for 4 weeks, then rehabilitation followed. In the patients with a damaged ligament, immobilisation in a short brace lasted until transarticular wires were removed. All patients were followed up for a year at least. At follow-up, the injured wrist was examined

  17. Traumatic Vertebral Fractures and Concomitant Fractures of the Rib in Southwest China, 2001 to 2010

    Science.gov (United States)

    Wang, Hongwei; Zhou, Yue; Ou, Lan; Li, Changqing; Liu, Jun; Xiang, Liangbi

    2015-01-01

    Abstract To our knowledge, the clinical characteristics of traumatic vertebral fractures and concomitant fractures of the rib (TVF-RF) have not been described in previous studies. To investigate the clinical characteristics of patients managed for TVF-RF. A retrospective study of 3142 patients who presented with traumatic vertebral fractures was performed. Two hundred twenty-six patients (7.2%) suffered from TVF-RF. Incidence rate ratios were then calculated with respect to the level of injury to the spine, the ASIA classification of neurological deficits and age. There were 171 male (75.7%) and 55 female (24.3%) patients with a mean age of 43.8 years. The most common mechanisms were falls from high heights in 81 cases and road traffic crashes in 67 cases. Right-sided rib injury occurred in 106 cases, left-sided injury occurred in 76 cases, and bilateral injury occurred in 44 cases. The most frequent location of the rib fractures was from the fourth rib to the ninth rib (70.3%, 510/725). Initial pulmonary complications (IPC) after trauma occurred in 116 cases (51.3%). The mortality rate for the entire group was 1.3% (3/226). The patients with thoracic vertebral fractures and neurological deficits had a higher frequency of multiple rib fractures and IPC than the other patients (P rib fractures, the frequency of IPC and mean intensive care unit (ICU) length of stay also increased. The rates of complications for patients with rib fractures were significantly different from those without rib fractures. We should pay much attention to the patients who presented with thoracic vertebral fractures and neurological deficits for minimizing further complications and mortality in such patients who had a higher frequency of multiple rib fractures and IPC than the other patients. PMID:26554809

  18. A case series of pediatric seymour fractures related to hoverboards: Increasing trend with changing lifestyle

    Directory of Open Access Journals (Sweden)

    A.E. Kattan

    2017-01-01

    Conclusion: We report a case series of a fracture pattern resulting from the improper/unsafe use of a hoverboard. This type of fracture occurs with a tremendous load of energy. Although improper use was a factor, design fault also plays a role in causing the injury. Parent awareness and supervision are important to prevent such injuries.

  19. Corruption and governance in a plural but fractured society: the case ...

    African Journals Online (AJOL)

    Corruption and governance in a plural but fractured society: the case of Nigeria. ... International Journal of Development and Management Review ... This paper examines the impact of bad governance, corruption and value-erosion in Nigeria as a result of the plural and mal-integrated nature of the Nigerian nation-state.

  20. Suture Anchor Fixation for Fifth Metatarsal Tuberosity Avulsion Fractures: A Case Series and Review of Literature.

    Science.gov (United States)

    Hong, Choon Chiet; Nag, Kushal; Yeow, Huifen; Lin, Adrian Zhigao; Tan, Ken Jin

    2018-05-17

    Fifth metatarsal tuberosity avulsion fractures are common. Despite good outcomes with nonoperative treatment, acute fractures with displacement, intra-articular involvement, comminution, or painful nonunion have been reported to benefit from early open reduction and internal fixation, especially in athletes. No consensus has been reached regarding the best surgical fixation technique. We present a case series of 4 patients with displaced fifth metatarsal tuberosity avulsion fractures and an innovative technique of fixation for the tuberosity avulsion fractures using a suture anchor. Copyright © 2018 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  1. First rib fractures: not always a hallmark of severe trauma-a report of three cases

    Directory of Open Access Journals (Sweden)

    Jaiswal Atin

    2013-08-01

    Full Text Available 【Abstract】According to medical literature, fracture of the first rib is quite rare and the bilateral condition is especially rare. This type of fracture is usually associated with severe intrathoracic trauma and other bony or neurovascular injuries, thus can be considered as a harbinger of major trauma. However here we present three cases of low velocity first rib fractures without any major trauma or multisystem injuries. All the three patients were treated conservatively and did well on simple analgesics and rest and had no early or late complications. It can be seen that not all the first rib fractures are associated with major trauma or multisystem injuries. There is a variant of first rib fracture with low velocity injuries which is not associated with any major complications in contrast to majority of first rib fractures associated with high velocity injuries. Causative factor of such injuries may be violent muscular contraction of scalenus anterior or serratus anterior, but not direct trauma. Key words: Rib fractures; Wounds and injuries; Multiple trauma

  2. Intraoperative ultrasound in colorectal surgery.

    Science.gov (United States)

    Greif, Franklin; Aranovich, David; Hananel, Nissim; Knizhnik, Mikhail; Belenky, Alexander

    2009-09-01

    To assess the accuracy of intraoperative ultrasound (IOUS) as a localizing technique for colorectal resections, and its impact on surgical management. Twenty-five patients (15 men and 10 women; mean age, 74.4 years) with early cancers (p T1), or polyps, not amenable to endoscopic removal were selected. IOUS was used as a sole method of intraoperative localization. Its performance was evaluated through review of preoperative colonoscopy reports, intraoperative findings, histopathology reports, and clinical follow-up. The lesions were situated in the cecum (n = 5), ascending colon (n = 3), transverse colon (n = 4), descending colon (n = 7), and rectum (n = 6). IOUS technique allowed correct localization in 24 of 25 patients, visualization of the bowel wall, and its penetration by malignant tumors. In rectal lesions, IOUS showed clearly the tumor and its margin, which facilitated performance sphincter-sparing procedure. In patients with small polyps and early cancers of colon and rectum, IOUS may be effectively used as a sole method of intraoperative localization and provide additional information that may alter decision making with regard to surgical technique. (c) 2009 Wiley Periodicals, Inc.

  3. Another fractured neck of femur: do we need a lateral X-ray?

    Science.gov (United States)

    Almazedi, B; Smith, C D; Morgan, D; Thomas, G; Pereira, G

    2011-05-01

    This study aimed to define the role of the lateral X-ray in the assessment and treatment planning of proximal femoral fractures. Occult fractures were not included. Radiographs from 359 consecutive patients with proximal femoral fractures admitted to our emergency department over a 12 month period were divided into anteroposterior (AP) views and lateral views. Three blinded reviewers independently assessed the radiographs, first AP views alone then AP plus lateral views, noting the fracture classification for each radiograph. These assessments were then compared with the intra-operative diagnosis, which was used as the gold standard. A 2 × 2 contingency square table was created and Pearson's χ(2) test was used for statistical analysis. The rate of correct classification by the reviewers was improved by the assessment of the lateral X-ray in addition to the AP view for intracapsular fractures (pview in intracapsular fractures was the detection of displacement where the fracture appeared undisplaced on the initial AP view. This study provides statistical evidence that one view is adequate and safe for the majority of hip fractures. The lateral radiograph should not be performed routinely in order to make considerable savings in money and time and to avoid unnecessary patient discomfort.

  4. The Role of Intraoperative Cerebral Angiography in Transorbital Intracranial Penetrating Trauma: A Case Report and Literature Review.

    Science.gov (United States)

    Riley, Jonathan P; Boucher, Andrew B; Kim, Denise S; Barrow, Daniel L; Reynolds, Matthew R

    2017-01-01

    present case). Given that CT angiography and intraoperative videoangiography may miss a potentially treatable traumatic arterial injury, IOA can help determine whether cerebral revascularization may be necessary. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Intraoperative computed tomography with integrated navigation system in a multidisciplinary operating suite.

    Science.gov (United States)

    Uhl, Eberhard; Zausinger, Stefan; Morhard, Dominik; Heigl, Thomas; Scheder, Benjamin; Rachinger, Walter; Schichor, Christian; Tonn, Jörg-Christian

    2009-05-01

    We report our preliminary experience in a prospective series of patients with regard to feasibility, work flow, and image quality using a multislice computed tomographic (CT) scanner combined with a frameless neuronavigation system (NNS). A sliding gantry 40-slice CT scanner was installed in a preexisting operating room. The scanner was connected to a frameless infrared-based NNS. Image data was transferred directly from the scanner into the navigation system. This allowed updating of the NNS during surgery by automated image registration based on the position of the gantry. Intraoperative CT angiography was possible. The patient was positioned on a radiolucent operating table that fits within the bore of the gantry. During image acquisition, the gantry moved over the patient. This table allowed all positions and movements like any normal operating table without compromising the positioning of the patient. For cranial surgery, a carbon-made radiolucent head clamp was fixed to the table. Experience with the first 230 patients confirms the feasibility of intraoperative CT scanning (136 patients with intracranial pathology, 94 patients with spinal lesions). After a specific work flow, interruption of surgery for intraoperative scanning can be limited to 10 to 15 minutes in cranial surgery and to 9 minutes in spinal surgery. Intraoperative imaging changed the course of surgery in 16 of the 230 cases either because control CT scans showed suboptimal screw position (17 of 307 screws, with 9 in 7 patients requiring correction) or that tumor resection was insufficient (9 cases). Intraoperative CT angiography has been performed in 7 cases so far with good image quality to determine residual flow in an aneurysm. Image quality was excellent in spinal and cranial base surgery. The system can be installed in a preexisting operating environment without the need for special surgical instruments. It increases the safety of the patient and the surgeon without necessitating a change

  6. Single high dose intraoperative electrons for advanced stage pancreatic cancer: Phase I pilot study

    International Nuclear Information System (INIS)

    Goldson, A.L.; Ashaveri, E.; Espinoza, M.C.

    1981-01-01

    Phase I toxicity studies with intraoperative radiotherapy proved to be a feasible adjunct to surgery for unresectable malignancies of the pancreas at Howard University Hospital. There have been minimal side effects or complications related to the combination of limited surgical decompression and intraoperative radiotherapy alone. The toxic effects of intraoperative radiotherapy on normal tissues is being assessed on a dose volume basis. Doses of 2000 to 2500 rad in a single exposure to include the pancreas, regional nodes and duodenum are acceptable if the total treatment volume is less than or equal to 100 cm. The tumoricidal effects on the cancer are demonstratable when one reviews the pathological specimens that illustrate massive tumor necrosis and fibros replacement, but in all cases reviewed, viable cancer was noted. Intraoperative radiotherapy, therefore, represents a significant boost dose for resectable, partially resectable or non-resectable tumors when added to conventional external beam irradiation and/or chemotherapy. Preliminary clinical data and minimal toxicity justifies further investigation

  7. Post-traumatic cerebellar infarction due to vertebral artery foramina fracture: case report

    Directory of Open Access Journals (Sweden)

    Moscote-Salazar Luis Rafael

    2016-03-01

    Full Text Available Posttraumatic cerebral infarction is an uncommon cause of morbidity and mortality and many studies have highlighted that trauma needs to considered as causative factor for cerebellar infarction. We present a case of cerebellar infarction in a 35 year old young patient secondary to vertebral fracture involving the vertebral foramen and vertebral artery injury. CT scan cervical spine showed C2-3 fracture on left side with fracture extending into the left vertebral foramen. A CT scan angiogram could not be performed because of poor neurological status. Possibly the infarction was due to left vertebral artery injury. Without surgical intervention prognosis of these patients remain poor. Prognosis of patients with traumatic cerebellar infarction depends on the neurological status of the patient, intrinsic parenchymal damage and more importantly extrinsic compression of the brainstem by the edematous cerebellar hemispheres.

  8. Debate: Pro intraoperative radiation therapy in breast cancer; Debat: pour la radiotherapie peroperatoire dans le cancer du sein

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, J.B.; Lemanski, C.; Azria, D. [Departement de radiotherapie, CRLC Val-d' Aurelle-Paul-Lamarque, 208, rue des Apothicaires, 34298 Montpellier cedex 5 (France); Gutowski, M.; Rouanet, P.; Saint-Aubert, B. [Departement de chirurgie, CRLC Val-d' Aurelle-Paul-Lamarque, 208, rue des Apothicaires, 34298 Montpellier cedex 5 (France)

    2011-10-15

    The use of intraoperative radiation therapy in breast cancer patients started about 20 years ago. Several retrospective and prospective studies have been published. Intraoperative radiation therapy was initially given as a boost to the tumour bed, followed by whole-breast irradiation. These studies have demonstrated the feasibility of the technique, with local control rates and cosmetic results similar to those obtained with standard treatments. Accelerated partial breast irradiation yields local recurrence rates as low as those observed after whole-breast irradiation. Intraoperative radiation therapy as a single irradiation modality with a unique dose has been investigated in recent prospective studies showing satisfactory local results. Intraoperative radiation therapy can be proposed either as a boost or as a unique treatment in selected cases (tumour size, nodal and hormonal status, patient's age). Intraoperative radiation therapy can be delivered by orthovoltage (50 kV) X-rays from mobile generators, or by electrons from linear accelerators, mobile or fixed, dedicated or not to intraoperative radiation therapy. (authors)

  9. Fracture of the femoral component after a lightning strike injury: A case report

    Directory of Open Access Journals (Sweden)

    Xavier Lizano-Díez

    2017-01-01

    Full Text Available A fracture of the stem in a total hip arthroplasty (THA is an uncommon complication. We report a case of femoral stem fracture in a 55-year-old male patient after a lightning strike. A revision was conducted using a Wagner osteotomy and a revision prosthesis. Dall-Milles cerclages were used to close the osteotomy. The postoperative evolution was satisfactory, with an immediate partial weight bearing, consolidation of the osteotomy after three months and return to daily activity without pain.

  10. Intraoperative positioning of the hindfoot with the hindfoot alignment guide: a pilot study.

    Science.gov (United States)

    Frigg, Arno; Jud, Lukas; Valderrabano, Victor

    2014-01-01

    In a previous study, intraoperative positioning of the hindfoot by visual means resulted in the wrong varus/valgus position by 8 degrees and a relatively large standard deviation of 8 degrees. Thus, new intraoperative means are needed to improve the precision of hindfoot surgery. We therefore sought a hindfoot alignment guide that would be as simple as the alignment guides used in total knee arthroplasty. A novel hindfoot alignment guide (HA guide) has been developed that projects the mechanical axis from the tibia down to the heel. The HA guide enables the positioning of the hindfoot in the desired varus/valgus position and in plantigrade position in the lateral plane. The HA guide was used intraoperatively from May through November 2011 in 11 complex patients with simultaneous correction of the supramalleolar, tibiotalar, and inframalleolar alignment. Pre- and postoperative Saltzman views were taken and the position was measured. The HA guide significantly improved the intraoperative positioning compared with visual means: The accuracy with the HA guide was 4.5 ± 5.1 degrees (mean ± standard deviation) and without the HA guide 9.4 ± 5.5 degrees (P guide (2 avoided osteotomies, 5 additional osteotomies). The HA guide helped to position the hindfoot intraoperatively with greater precision than visual means. The HA guide was especially useful for multilevel corrections in which the need for and the amount of a simultaneous osteotomy had to be evaluated intraoperatively. Level IV, case series.

  11. Somatostatin receptor scintigraphy and intraoperative gamma probe detection in the localisation and treatment of pancreatic insulinoma

    International Nuclear Information System (INIS)

    Loh, Nelson K.; Macdonald, William B.; Dunne, Marina L.; Rao, Sudhakar

    2009-01-01

    Full text: Aims: We report a case of insulinoma that was successfully enucleated under radio-guidance after an initial unsuccessful laparotomy. This case highlights the utility of Somatostatin Receptor Scintigraphy (SRS) and gamma probe in the localisation and treatment of neuroendocrine tumours. Methods: The patient presented with recurrent hypoglycaemia. An abdominal CT scan identified a lesion in the uncinate process of the pancreas, however, laparotomy with use of intraoperative ultrasound failed to localise the lesion. SRS with SPECTICT was then requested by the surgical team with a view to radio-guided surgery. Results: SRS demonstrated an octreotide-avid tumour in the posterior uncinate process of the pancreas, and confirmed suitability for radio-guided surgery. At re-exploration, the surgeon was again unable to palpate the lesion or localise it with intraoperative ultrasound, however, the lesion was successfully detected and removed with the use of a gamma probe. A postoperative SRS confirmed complete excision and histopathology was diagnostic of insulinoma. Conclusion: This case highlights the utility of SRS in the intraoperative localisation and surgical excision of neuroendocrine tumours. The lesion was unable to be localised clinically or with intraoperative ultrasound but was successfully detected with scintigraphic techniques. The surgical team acknowledge that the use of a gamma probe enabled enucleation of the insulinoma, which obviated the need for an invasive Whipple's procedure.

  12. Hamate hook stress fracture in a professional bowler: Case report of an unusual causal sport.

    Science.gov (United States)

    How Kit, N; Malherbe, M; Hulet, C

    2017-02-01

    Stress fracture of the hook of the hamate is uncommon and is usually seen in sports involving a club, racquet or bat (i.e., golf, tennis or baseball). It is caused by direct blunt trauma. We report an unusual case of stress fracture with non-union in a 23-year-old professional bowler, probably caused by endogenous constraints, 1 year after the start of symptoms. Treatment consisted of surgical resection of the hook of the hamate. Multimodal imaging of this fracture is reviewed. Copyright © 2016. Published by Elsevier Masson SAS.

  13. [Manipulative reduction and external fixation with cardboard splint for the treatment of calcaneal fractures: a 60-case report].

    Science.gov (United States)

    Hao, Bo-Chuan; Xie, Ke-Bo

    2014-07-01

    To investigate the therapeutic effects of manipulative reduction for calcaneal fractures. From January 2009 to June 2012, 53 cases (60 affected feet) of Sanders type I-IV calcaneal fractures were treated by manipulative reduction and external fixation with cardboard splint,including 45 males and 8 females with an average age of (33.5 +/- 1.54) years old ranging from 18 to 65. The course of disease ranged 0.5 h to 7 d. Before treatment the feet were swelling, ache and activity limitation in evidence, some feet were wide flat deformity, the cortical bone was broken in the imaging examination. All selected cases were evaluated using Creighton-Nebraska health foundation assessment scale for fractures of calcaneus. All cases were followed up at 12 months after treatment, 13 feet got excellent curative effect, 34 good, 11 moderate and 2 poor. Manipulative reduction for Sanders type I-IV calcaneal fractures could get excellent curative effect. Manipulative reduction for calcaneal fractures could avoid surgical trauma while assure high curative effects. Manipulative reduction is not only economical and easy therapy, but also can restore maximum function of the calcaneus with few complications and facilitate early rehabilitation of ankle and joint function.

  14. REVIEW OF 40 CASES OF ISOLATED FRACTURE MANDIBLE

    Directory of Open Access Journals (Sweden)

    Shashikant Kondiram Mhashal

    2016-10-01

    Full Text Available BACKGROUND Mandible fractures are a frequent injury because of the mandible's prominence and relative lack of support. The purpose of this study is to clinically determine the most common sites and the prevalence of isolated fracture mandible in our scenario and determine most common traumatic aetiology factor responsible for fracture mandible. Numerous investigators have reported studies on populations on all continents; fractures of the mandible have been reported to account for 36-70% of all maxillofacial fractures. All reports apparently show a higher frequency in males aged 21-30 yrs. There is an emerging trend towards an increase in the frequency of violent mechanisms of fracture and in the proportion of adolescents and young adults sustaining such injuries. MATERIALS AND METHODS Patients treated at the Otorhinolaryngology Head and Neck Surgery Department of B.D.B.A. Hospital from a period between January 2014 to January2016 were (retrospectively evaluated with respect to age groups, gender, aetiology, localisation, type of fractures and treatment. RESULTS Total number of patients 38, 2 patients had bilateral fracture, males 27 (71.05%, females 11 (28.95%. Anatomical location symphysis and parasymphysis 14 (35%, condylar 12 (30%, body 7 (17.5%, angle 6 (15%, coronoid 1 (2.5%. Aetiological factors road traffic accidents 19 (50%, assault 13 (34.24%, fall 3 (7.89%, work-related trauma 2 (5.26%, sports trauma 1 (2.6%. CONCLUSION This study indicates that most common fracture in adult patient were symphysis and parasymphysis, second most common were condylar followed by body fracture and angle fracture. The most common cause of the injury maybe road traffic accidents, second most common assault followed by work related injuries, fall and sports injuries.

  15. Hydrodynamic study of syringomyelia by MRI and intraoperative ultrasonography

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Takaya, Mikio; Minamikawa, Jun; Ishikawa, Masatsune; Kikuchi, Haruhiko; Minami, Shunsuke

    1989-01-01

    Syringomyelic cavities were studied with magnetic resonance imaging (MRI) in eleven patients with special reference to the hemodynamic contribution to the pathogenesis of syringomyelia. They were also studied intraoperatively with ultrasonography (USG) in five patients. Syrinx cavities combined with lumbosacral lipomyelomeningocele or with spinal stenosis did not present a flow-void phenomenon reflecting pulsatile movements of syrinx fluid. On serial MRI study in those the patients, enlargement of the syrinx cavity was not observed. Syrinx cavities occupying the caudal part of the spinal cord did not develop either. These cases were not treated surgically but followed conservatively. On the other hand, the flow-void sign in the syrinx cavities was present on MRI in patients who also had Chiari type I or type II malformations. They were treated with a syringo-subarachnoid shunt. In these cases, intraoperative USG disclosed marked fluctuation of syrinx cavity size synchronous with the motions of pulmonary ventilation. In all of them, clinical signs and symptoms improved postoperatively to various degrees. These results suggest that both the flow-void sign in the syrinx cavity on MRI and marked fluctaution of cavity size on intraoperative USG are indications for the shunt operation and support William's revised theory (1987). Fluctuation of cystic cavity size synchronous with ventilation suggests that venous pressure in the spinal subarachnoid space contributes to the pathogenesis of syringomyelic cavities. Further analysis of the fluctuation of cystic cavities by video monitoring will provide further information on the etiology and other clinical problems of syringomyelia. (author)

  16. SIMULTANEOUS BILATERAL AVULSION FRACTURE OF THE TIBIAL TUBEROSITY IN A TEENAGER: CASE REPORT AND THERAPY USED.

    Science.gov (United States)

    E Albuquerque, Rodrigo Pires; Giordano, Vincenzo; Carvalho, Antônio Carlos Pires; Puell, Thiago; E Albuquerque, Maria Isabel Pires; do Amaral, Ney Pecegueiro

    2012-01-01

    Simultaneous bilateral avulsion fracture of the tibial tuberosity in teenagers is a rare lesion. We describe the first case in the literature, in a teenage girl who sustained a fall while jumping during a volleyball match. No predisposing factors were iden tified. The lesions were treated with open surgical reduction and internal fixation. The aim of the present study was to present a case of simultaneous bilateral avulsion fracture of the tibial tuberosity in a teenage girl and the therapy used.

  17. The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures.

    Science.gov (United States)

    Forman, Jordanna M; Urruela, Adriana M; Egol, Kenneth A

    2011-12-01

    The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This

  18. Usefulness of virtual images of the visceral pleura in identifying the localization of peripheral small pulmonary nodules intraoperatively

    International Nuclear Information System (INIS)

    Kambayashi, Takatoyo

    2011-01-01

    The objective of this study was to assess the usefulness of virtual images of the visceral pleura in identifying the localization of peripheral small pulmonary nodules intraoperatively. We examined 12 cases with 12 peripheral small pulmonary nodules between 2008 and 2010. All lesions were predicted to be difficult to identify during surgery, and virtual images of the visceral pleura were made and evaluated before surgery. We predicted the usefulness of virtual images of the visceral pleura in identifying the localization of peripheral small pulmonary nodules. The mean maximum dimensions were 10.5±4.36 mm. The mean depth from the visceral pleura was 4.0±4.67 mm. The lesions were the solid type in 6 cases and the ground-glass opacity type in 6 cases. In 7 cases primary lung cancer was present, while the other 5 cases had only benign lesions. In all cases, changes in the visceral pleura could be identified with virtual images of the visceral pleura before surgery. We identified 7 lesions out of 12 intraoperatively. The reasons for the failure to identify the lesions were an inability to adequately observe the visceral pleura because of pleural adhesion, or failure to perform single lung ventilation in 3 cases. Another reason was that the changes in the visceral pleura were too minor to identify intraoperatively (2 cases). Virtual images of the visceral pleura may be useful for identifying the localization of peripheral small pulmonary nodules, and the prediction of whether or not the identification of lesions is possible intraoperatively, without preoperative marking in order to identify peripheral pulmonary nodules. (author)

  19. Application of Local Vibrations in Delayed and Non-Union Fractures: a Case Study

    Science.gov (United States)

    Trombetta, Chiara; Abundo, Paolo; Foti, Calogero; Rosato, Nicola

    2011-02-01

    The aim of the study was to assess the efficacy of local vibration treatments (LV) in delayed-union and non-union fractures, through therapeutic exercise vibration (TEV) practice, analysing the radiological trend. The Medical Engineering Service of the Fondazione Policlinico Tor Vergata in collaboration with the Chair-Department of Rehabilitation Medicine of the University of Rome Tor Vergata and the Boscosystem company, is developing a device dedicated to LV application, to favour bone regeneration and muscle strengthening. This case report analyses the bone activity of a male patient presenting a right tibial fracture, treated with TEV. At the end of the TEV program, clinical results confirmed independent ambulation with disappearance of perimalleolar edema, while radiographic images revealed the presence of bone repair activity around the fracture line.

  20. Application of Local Vibrations in Delayed and Non-Union Fractures: a Case Study

    International Nuclear Information System (INIS)

    Trombetta, Chiara; Abundo, Paolo; Foti, Calogero; Rosato, Nicola

    2011-01-01

    The aim of the study was to assess the efficacy of local vibration treatments (LV) in delayed-union and non-union fractures, through therapeutic exercise vibration (TEV) practice, analysing the radiological trend. The Medical Engineering Service of the Fondazione Policlinico Tor Vergata in collaboration with the Chair-Department of Rehabilitation Medicine of the University of Rome Tor Vergata and the Boscosystem company, is developing a device dedicated to LV application, to favour bone regeneration and muscle strengthening. This case report analyses the bone activity of a male patient presenting a right tibial fracture, treated with TEV. At the end of the TEV program, clinical results confirmed independent ambulation with disappearance of perimalleolar edema, while radiographic images revealed the presence of bone repair activity around the fracture line.

  1. Pilot study of intraoperative digital imaging with the use of a mammograph for assessment of bone surgical margins in the head and neck region

    International Nuclear Information System (INIS)

    Ntomouchtsis, A.; Xinou, K.; Patrikidou, A.; Paraskevopoulos, K.; Kechagias, N.; Tsekos, A.; Balis, G.C.; Gerasimidou, D.; Thuau, H.; Mangoudi, D.; Vahtsevanos, K.

    2013-01-01

    Aim: To investigate alternative possibilities for the intraoperative evaluation of surgical margins after bone resection utilizing more conventional hospital infrastructure technologies. Materials and methods: A small pilot study was performed using digital mammograph imaging intraoperatively on 16 surgical specimens of bone tumours or malignancies with bone infiltration of the head and neck area, with the aim of evaluating the resection margins. Results: In thirteen cases the intraoperative specimen images indicated clinically complete excision. In two cases incomplete resection or close proximity of margins was detected, which required additional resection. Conclusions: The results indicated that intraoperative specimen radiography can prove useful in evaluating completeness of excision. The significance of intraoperative assessment of surgical margin is of paramount importance when immediate reconstruction is performed. This proposed method is cheap, easy to perform and fast. Its cost–benefit ratio is superior than that of any other available technique. Intraoperative analysis of specimens with digital mammography imaging can potentially become a useful tool for immediate evaluation of osseous margins after resection

  2. Isolated Juvenile Xanthogranuloma in Thoracic Spine: Intraoperative Cytological Diagnosis of a Rare Presentation

    Directory of Open Access Journals (Sweden)

    Shashi Singhvi

    2014-06-01

    Full Text Available Juvenile Xanthogranulomas (JXG are benign proliferative disorders of non-Langerhans histiocytes, which present in children as multiple, self-limited, cutaneous lesions. The extracutaneous manifestations of JXG are uncommon, and isolated JXG involving the spinal column is extremely rare. We report here a case of isolated juvenile xanthogranuloma in thoracic spine correctly diagnosed intraoperatively on crush smear cytology and later confirmed by histopathological and immunohistochemical studies. This case report draws attention to the fact that isolated xanthogranuloma should be considered among possible diagnoses of spinal tumor in children. Also, since the long term survival depends on complete surgical resection, a correct intraoperative diagnosis is extremely important for optimal management and prognosis of the patient. [J Interdiscipl Histopathol 2014; 2(3.000: 158-162

  3. Transverse dispersion in heterogeneous fractures

    International Nuclear Information System (INIS)

    Dershowitz, Bill; Shuttle, Dawn; Klise, Kate; Outters, Nils; Hermanson, Jan

    2004-12-01

    This report evaluates the significance of transverse dispersion processes for solute transport in a single fracture. Transverse dispersion is a potentially significant process because it increases the fracture surface area available for sorptive and diffusive properties, and has the potential to transport solute between what would otherwise be distinctive, streamline pathways. Transverse dispersion processes are generally ignored in one-dimensional repository performance assessment approaches. This report provides an initial assessment of the magnitude of transverse dispersion effect in a single heterogeneous fracture on repository safety assessment. This study builds on a previous report which considered the network effects on transport dispersion including streamline routing and mixing at fracture intersections. The project uses FracMan software. This platform has been extensively used by SKB in other projects. FracMan software is designed to generate and analyze DFN's as well as to compute fluid flow in DFN's with the MAFIC Finite element method (FEM) code. Solute transport was modeled using the particle tracking inside MAFIC, the 2-D Laplace Transform Galerkin inside PAWorks/LTG, and the 1-D Laplace Transform approach designed to replicate FARF31 inside GoldSim.The study reported here focuses on a single, 20-meter scale discrete fracture, with simplified boundary conditions intended to represent the position of this fracture within a fracture network. The range of assumptions made regarding fracture heterogeneity were as follows: Base case, Heterogeneous fracture, geostatistical field, correlation length 0.01 m. Case 1a, Homogeneous fracture, transmissivity = 10 -7 m 2 /s. Case 1b, Heterogeneous fracture, non-channeled geostatistical field correlation length 5 m. Case 1c, Heterogeneous fracture, channeled, anisotropic geostatistical field. Case 1d, Heterogeneous fracture, fracture intersection zone (FIZ) permeability enhanced. Case 5, Simple channelized

  4. Increased risk of intraoperative and early postoperative periprosthetic femoral fracture with uncemented stems

    DEFF Research Database (Denmark)

    Lindberg-Larsen, Martin; Jørgensen, Christoffer C.; Solgaard, Søren

    2017-01-01

    Background and purpose - The use of uncemented fixation in total hip arthroplasty (THA) is increasing. Registry studies have indicated an increased risk of revision of uncemented implants due to early periprosthetic femoral fracture. In this paper, we describe the incidence and predisposing facto...

  5. Risk factors for falls with severe fracture in elderly people living in a middle-income country: a case control study

    Directory of Open Access Journals (Sweden)

    Bloch Katia V

    2008-08-01

    Full Text Available Abstract Background Fracture after falling has been identified as an important problem in public health. Most studies of risk factors for fractures due to falls have been carried out in developed countries, although the size of the elderly population is increasing fast in middle income countries. The objective of this paper is to identify risk factors for fall related to severe fractures in those aged 60 or more in a middle-income country. Methods A case-control study was carried out in Rio de Janeiro-Brazil based general hospitals between 2002–2003. Two hundred-fifty hospitalised cases of fracture were matched with 250 community controls by sex, age group and living area. Data were collected for socio-demographic variables, health status and drugs used before the fall. A conditional logistic regression model was fitted to identify variables associated with the risk of fall related severe fracture. Results Low body mass index, cognitive impairment, stroke and lack of urine control were associated with increased risk of severe fall related fractures. Benzodiazepines and muscle relaxants were also related to an increased risk of severe fractures while moderate use of alcohol was associated with reduced risk. Conclusion Although the association between benzodiazepines and fractures due to fall has been consistently demonstrated for old people, this has not been the case for muscle relaxant drugs. The decision to prescribe muscle relaxants for elderly people should take into account the risk of severe fracture associated with these drugs.

  6. Risk factors for falls with severe fracture in elderly people living in a middle-income country: a case control study.

    Science.gov (United States)

    Coutinho, Evandro S F; Fletcher, Astrid; Bloch, Katia V; Rodrigues, Laura C

    2008-08-26

    Fracture after falling has been identified as an important problem in public health. Most studies of risk factors for fractures due to falls have been carried out in developed countries, although the size of the elderly population is increasing fast in middle income countries. The objective of this paper is to identify risk factors for fall related to severe fractures in those aged 60 or more in a middle-income country. A case-control study was carried out in Rio de Janeiro-Brazil based general hospitals between 2002-2003. Two hundred-fifty hospitalised cases of fracture were matched with 250 community controls by sex, age group and living area. Data were collected for socio-demographic variables, health status and drugs used before the fall. A conditional logistic regression model was fitted to identify variables associated with the risk of fall related severe fracture. Low body mass index, cognitive impairment, stroke and lack of urine control were associated with increased risk of severe fall related fractures. Benzodiazepines and muscle relaxants were also related to an increased risk of severe fractures while moderate use of alcohol was associated with reduced risk. Although the association between benzodiazepines and fractures due to fall has been consistently demonstrated for old people, this has not been the case for muscle relaxant drugs. The decision to prescribe muscle relaxants for elderly people should take into account the risk of severe fracture associated with these drugs.

  7. INTRAOPERATIVE PREDONATION CONTRIBUTES TO BLOOD SAVING

    NARCIS (Netherlands)

    SCHONBERGER, JPAM; BREDEE, JJ; TJIAN, D; EVERTS, PAM; WILDEVUUR, CRH

    1993-01-01

    The merits of reinfusing prebypass-removed autologous blood (intraoperative predonation) to salvage blood and improve postoperative hemostasis are still debated, specifically for patients at a higher risk for bleeding. To evaluate the effect of intraoperative predonation on the platelet count, blood

  8. Vertebral fracture complications following radiation therapy. Report of two cases

    International Nuclear Information System (INIS)

    Tanaka, Hisato; Komine, Mitsunori; Kurokawa, Hiroaki

    2007-01-01

    We observed the outbreak time of a spinal compression fracture following radiation therapy and its natural course. Case 1 was a 88-year-old, woman. NTX 66.9. Underwent cobalt irradiation 54 Gy for esophageal cancer. Three months after irradiation, the first lumbar vertebra was found to de compressed, and low back pain occurred. Vacuum cleft phenomenon in X-P appeared after two weeks, but anterior callus formation appeared in eight weeks, after which the low back pain disappeared. Case 2 was a 77-year-old woman. NTX 86.5. Underwent irradiation 69 Gy for uterine carcinoma. Six months after the irradiation, the fourth/five lumbar vertebra were found to be compressed. Great collapse occurred in X-P after two weeks, but stabilized and did not aggravate thereafter. Low back pain also disappeared. Radiotherapy affects bone cells (osteoblasts, osteoclasts), inhibiting bone remodeling. As a result, deficient elastic resistance occurs. Vertebral bodies are also compressed in such a situation. After that normal callus formation starts from adjacent normal bone cells. The compression fracture observed ranged from three to six months after radiation. Natural course is well. Therefore conservative therapy is recommended. (author)

  9. Removal of a fractured needle during inferior alveolar nerve block: two case reports.

    Science.gov (United States)

    You, Jae-Seek; Kim, Su-Gwan; Oh, Ji-Su; Choi, Hae-In; Jih, Myeong-Kwan

    2017-09-01

    The inferior alveolar nerve block is the most common method of local anesthesia for intraoral surgery at the posterior mandibular region. However, unexpected complications may occur when administering the local anesthesia. One of these uncommon complications is the fracture of the needle. If the injection needle is broken during the surgery, it should be removed immediately. However, this is one of the most difficult procedures. In this report, we present two cases of needle fracture during the procedure, and its successful removal under general/local anesthesia administration.

  10. [{sup 18}F]FDG PET accurately differentiates infected and non-infected non-unions after fracture fixation

    Energy Technology Data Exchange (ETDEWEB)

    Wenter, Vera; Albert, Nathalie L.; Brendel, Matthias; Fendler, Wolfgang P.; Bartenstein, Peter [University of Munich, Department of Nuclear Medicine, Munich (Germany); Cyran, Clemens C. [University of Munich, Institute for Clinical Radiology, Munich (Germany); Friederichs, Jan; Mueller, Jan-Philipp; Militz, Matthias; Hungerer, Sven [BG Trauma Center Murnau, Department of Reconstructive Arthroplasty, Murnau (Germany); PMU Salzburg, Paracelsus Medical University, Salzburg (Austria); Hacker, Marcus [University of Vienna, Division of Nuclear Medicine, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria)

    2017-03-15

    Complete fracture healing is crucial for good patient outcomes. A major complication in the treatment of fractures is non-union. The pathogenesis of non-unions is not always clear, although implant-associated infections play a significant role, especially after surgical treatment of open fractures. We aimed to evaluate the value of [{sup 18}F]FDG PET in suspected infections of non-union fractures. We retrospectively evaluated 35 consecutive patients seen between 2000 and 2015 with suspected infection of non-union fractures, treated at a level I trauma center. The patients underwent either [{sup 18}F]FDG PET/CT (N = 24), [{sup 18}F]FDG PET (N = 11) plus additional CT (N = 8), or conventional X-ray (N = 3). Imaging findings were correlated with final diagnosis based on intraoperative culture or follow-up. In 13 of 35 patients (37 %), infection was proven by either positive intraoperative tissue culture (N = 12) or positive follow-up (N = 1). [{sup 18}F]FDG PET revealed 11 true-positive, 19 true-negative, three false-positive, and two false-negative results, indicating sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 85 %, 86 %, 79 %, 90 %, and 86 %, respectively. The SUV{sub max} was 6.4 ± 2.7 in the clinically infected group and 3.0 ± 1.7 in the clinically non-infected group (p <0.01). The SUV{sub ratio} was 5.3 ± 3.3 in the clinically infected group and 2.6 ± 1.5 in the clinically non-infected group (p <0.01). [{sup 18}F]FDG PET differentiates infected from non-infected non-unions with high accuracy in patients with suspected infections of non-union fractures, for whom other clinical findings were inconclusive for a local infection. [{sup 18}F]FDG PET should be considered for therapeutic management of non-unions. (orig.)

  11. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    Energy Technology Data Exchange (ETDEWEB)

    Sierralta, M P; Jofre, M J [Nuclear Medicine Department, Military Hospital, Santiago (Chile); Iglesis, R; Schwartz, R; Gomez, L; Velez, R [Surgery Department, Military Hospital, Santiago (Chile); Sandoval, R [Pathology Department, Military Hospital, Santiago (Chile)

    2002-09-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 {+-} 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node.

  12. Preliminary evaluation of intraoperative gamma probe detection of the sentinel node

    International Nuclear Information System (INIS)

    Sierralta, M.P.; Jofre, M.J.; Iglesis, R.; Schwartz, R.; Gomez, L.; Velez, R.; Sandoval, R.

    2002-01-01

    Introduction: The resurgence of the lymphoscintigraphy with the sentinel node concept and the availability of the intraoperative gamma probe have been proposed to avoid the morbidity of an unnecessary regional node dissection. The aim of the study was to evaluate the intraoperative gamma probe use after lymphoscintigraphy for the localization of the sentinel node. Material and methods: Twenty-nine patients were studied, 18 females (62%), mean age 60 ± 19 y.o. (range 24-86 y.o.) at the Military Hospital Nuclear Medicine Department. The reference diagnoses were 66% malignant melanoma, 21 % breast cancer, 10 % head and neck cancer and 3% vulvae cancer. Lymphoscintigraphs were performed with Tc99m-Dextran injected intradermally in four points around the primary lesion or around the biopsy site (for melanoma 500 microCi each one; for breast and head and neck 200 microCi each one). Afterwards, dynamic images were taken, followed by intraoperative gamma probe investigations in order to localize and remove the sentinel node. Additionally, isosulfan blue was injected before the surgery was made. Results: Lymphoscintigraphy was positive to detect sentinel node(s) in 20 patients (69%). During the surgery, 40 sentinel nodes were detected. In 33 cases, the intraoperative gamma probe was performed, of which 88 % were radioactives. In 35 nodes, the isosulfan blue was injected, of which 80 % were dyed. The correlation between both techniques was 75 %. The histology study of 37 samples demonstrated that 86% (n=32) were truly ganglionar nodes. Conclusion: The intraoperative gamma probe after lymphoscintigraphy is a useful technique for the localization of the sentinel node

  13. Imaging assessment of vertebral burst fracture

    International Nuclear Information System (INIS)

    Ding Jianlin; Liang Lihua; Wang Yujia

    2006-01-01

    Objective: To investigate the diagnostic value of radiography, CT and MRI in diagnosis of vertebral burst fracture. Methods: 51 patients with vertebral burst fracture were evaluated with X-ray, CT and MRI, including 3 cases in cervical vertebra, 18 cases in thoracic vertebra, and 30 cases in lumbar vertebra. The imaging features were comparatively studied. Results: Radiography showed decreased height of the vertebral body, increased antero-posterior diameter and the transverse diameter, and/or the widened interpedicle distance, the inter-spinous distance, as well as the bony fragment inserted into the vertebral canal in 28 cases(54.90%). X-ray findings similar to the compression fracture were revealed in 20 cases(39.21%). And missed diagnosis was made in 3 cases (5.88%). CT clearly demon-strated the vertebral body vertically or transversely burst crack in 49 cases (96.07%); bony fragment inserted into the vertebral canal and narrowed vertebral canal in 35 cases(68. 62% ); fracture of spinal appendix in 22 cases(43.14%). Meanwhile MRI showed abnormal signals within the spinal cord in 35 cases (68.62%),injured intervertebral disk in 29 cases(56.86% ), extradural hematoma in 12 cases(23.52% ) and torn posterior longitudinal ligament in 6 cases (11.76%). Conclusions: Radiography is the routine examination, while with limited diagnostic value in vertebral burst fracture. These patients who have nervous symptoms with simple compression fracture or unremarkable on X-ray should receive the CT or MRI examination. CT is better than MRI in demonstrating the fracture and the displaced bony fragment, while MRI is superior to CT in showing nervous injuries. CT and MRI will provide comprehensive information guiding clinical treatment of vertebral burst fracture. (authors)

  14. Computerized tomographic diagnosis of basal skull fracture

    International Nuclear Information System (INIS)

    Tanaka, Tokutaro; Shimoyama, Ichiro; Endoh, Mitsutoshi; Ninchoji, Toshiaki; Uemura, Kenichi.

    1984-01-01

    The diagnosis of basal skull fractures used to be difficult, particularly on the basis of routine skull roentgenography alone. We have now examined the diagnostic value of conventional computerized tomography in basal skull fractures. We studied 82 cases clinically diagnosed as basal skull fractures. We examined them based on at least one of the following computerized tomographic criteria for basal skull fractures: 1) fracture line(s), 2) intracranial air, 3) fluid in the paranasal sinuses, and 4) fluid in the middle ear, including the mastoid air cells. The signs of the fracture line and of the intracranial air are definite indications of basal skull fracture, but the signs of fluid in the paranasal sinuses and/or in the middle ear are not definite. When combined, however, with such other clinical signs as black eye, Battle's sign, CSF leakage, CSF findings, and profuse nasal or ear bleeding, the diagnosis is more reliable. Seventy cases (85.4%) in this series had basal skull fractures according to our computerized tomographic criteria. Among them , 26 cases (31.7%) were diagnosed with fracture lines, 17 cases (20.7%) with intracranial air, 16 cases (19.5%) with fluid in the paranasal sinuses, 10 cases (12.2%) with fluid in the middle ear, and one case (1.2%) with fluid in both. Twelve cases (14.6%) of the 82 cases clinically diagnosed as basal skull fractures could not have been diagnosed on our computerized tomographic criteria alone. We diagnosed them because of CSF leakage, CSF findings, surgical findings, etc. (author)

  15. Intraoperative transfusion practices in Europe

    DEFF Research Database (Denmark)

    Meier, J; Filipescu, D; Kozek-Langenecker, S

    2016-01-01

    BACKGROUND: Transfusion of allogeneic blood influences outcome after surgery. Despite widespread availability of transfusion guidelines, transfusion practices might vary among physicians, departments, hospitals and countries. Our aim was to determine the amount of packed red blood cells (p......RBC) and blood products transfused intraoperatively, and to describe factors determining transfusion throughout Europe. METHODS: We did a prospective observational cohort study enrolling 5803 patients in 126 European centres that received at least one pRBC unit intraoperatively, during a continuous three month...... period in 2013. RESULTS: The overall intraoperative transfusion rate was 1.8%; 59% of transfusions were at least partially initiated as a result of a physiological transfusion trigger- mostly because of hypotension (55.4%) and/or tachycardia (30.7%). Haemoglobin (Hb)- based transfusion trigger alone...

  16. Principles for Management of Intraoperative Acute Type A Aortic Dissection.

    Science.gov (United States)

    Gukop, Philemon; Chandrasekaran, Vankatachalam

    2015-12-01

    Intraoperative Type A aortic dissection is a rare pathology with incidence of 0.06-0.32%. It is associated with a high mortality between 30-50%. Some associated risk factors, including hypertension, enlarged aorta, peripheral vascular disease, advanced age, atheroma, and high arterial pressure on cardiopulmonary bypass, have been identified. Modification of these risk factors could reduce the incidence of this event. Prompt diagnosis and management, with the aid of intraoperative trans-esophageal echocardiography and/or epi-aortic ultrasound has been shown to reduce the mortality to 17%. We illustrate the principles of management of this pathology with the case of a 62-year-old female who developed acute Type A aortic dissection while undergoing minimally invasive mitral valve repair.

  17. An analysis of 214 cases of rib fractures

    OpenAIRE

    Karadayi, Sule; Nadir, Aydin; Sahin, Ekber; Celik, Burcin; Arslan, Sulhattin; Kaptanoglu, Melih

    2011-01-01

    INTRODUCTION: Rib fractures are the most common type of injury associated with trauma to the thorax. In this study, we investigated whether morbidity and mortality rates increased in correlation with the number of fractured ribs. MATERIALS AND METHODS: Data from 214 patients with rib fractures who applied or were referred to our clinic between January 2007 and December 2008 were retrospectively evaluated. The patients were allocated into three groups according to the number of fractures: 1) p...

  18. [Role of centro-medullary nailing in fractures of the distal quarter of the leg: about 30 cases].

    Science.gov (United States)

    Margad, Omar; Boukhris, Jalal; Sallahi, Hicham; Azriouil, Ouahb; Daoudi, Mohamed; Koulali, Khalid

    2017-01-01

    The fractures of the distal quarter of the leg are characterized by fracture line located at the level of the lower quarter of the tibia, according to Gerard and Evrard definition [1]. They are serious and pose problems for consolidation, immobilization and stability. We here describe our experience in the Department of Orthopaedics and Traumatology at the Avicenne Military Hospital, Marrakech. We report 30 cases of closed fractures of the lower quarter of the leg treated with centro-medullary nailing over a period of 10 years (January 2001-December 2010). Locked nailing was performed in 80% of cases and simple nailing was performed in the other cases. The average age of patients was 36 years. There was a clear male predominance (27 men, 3 women). The average time for consolidation was 17 weeks and functional outcomes were satisfactory. A single case of infection occurred 6 months after surgery (3.3%) and no other complication was reported. Malunion was detected in 30% of patients. Our epidemiological data and results were almost identical to those in the literature. Angular results were significantly lower than those obtained with the series of plates. By contrast, data on infections called for caution and some nails produced excellent angular results when nail fixation was stable. In the light of these results, codified indications for locked centro-medullary nailing should be extended to the fractures of the lower quarter of the leg, provided that stable fixation using double screw distal locking and primary osteosynthesis of distal fibula fractures are performed.

  19. Femoral neck fractures after removal of hardware in healed trochanteric fractures.

    Science.gov (United States)

    Barquet, Antonio; Giannoudis, Peter V; Gelink, Andrés

    2017-12-01

    Hardware removal in healed trochanteric fractures (TF) in the absence of infection or significant mechanical complications is rarely indicated. However, in patients with persistent pain, prominent material and discomfort in the activities of daily living, the implant is eventually removed. Publications of ipsilateral femoral neck fracture after removal of implants from healed trochanteric fractures (FNFARIHTF) just because of pain or discomfort are rare. The purpose of this systematic review of the literature is to report on the eventual risk factors, the mechanisms, the clinical presentation, and frequency, and to pay special emphasis in their prevention. A comprehensive review of the literature was undertaken using the PRISMA guidelines with no language restriction. Case reports of FNFARIHTF and series of TF with cases of FNFARIHTF due to pain or discomfort published between inception of journals to December 2016 were eligible for inclusion. Relevant information was divided in two parts. Part I included the analysis of cases of FNFARIHTF, with the objective of establishing the eventual risk factors, mechanisms and pathoanatomy, clinical presentation and diagnosis, treatment and prevention. Part II analyzed series of TF which included cases of FNFARIHTF for assessing the incidence of femoral neck fractures in this condition. Overall 24 publications with 45 cases of FNFARIHTF met the inclusion criteria. We found that the only prevalent factors for FNFARIHTF were: 1) preexisisting systemic osteoporosis, as most patients were older and elder females, with lower bone mineral density and bone mass; 2) local osteoporosis as a result of preloading by the fixation device in the femoral neck, leading to stress protection, reducing the strain at the neck, and increasing bone loss and weakness; and 3) the removal of hardware from the femoral neck, with reduction of the failure strength of the neck. The femoral neck fractures were spontaneous, i.e. not related to trauma or

  20. Donor disc attachment assessment with intraoperative spectral optical coherence tomography during descemet stripping automated endothelial keratoplasty

    Directory of Open Access Journals (Sweden)

    Edward Wylegala

    2013-01-01

    Full Text Available Optical coherence tomography has already been proven to be useful for pre- and post-surgical anterior eye segment assessment, especially in lamellar keratoplasty procedures. There is no evidence for intraoperative usefulness of optical coherence tomography (OCT. We present a case report of the intraoperative donor disc attachment assessment with spectral-domain optical coherence tomography in case of Descemet stripping automated endothelial keratoplasty (DSAEK surgery combined with corneal incisions. The effectiveness of the performed corneal stab incisions was visualized directly by OCT scan analysis. OCT assisted DSAEK allows the assessment of the accuracy of the Descemet stripping and donor disc attachment.