  1. High-dose-rate brachytherapy for uterine cervical cancer: the results of different fractionation regimen

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Won Sup; Kim, Tae Hyun; Yang, Dae Sik; Choi, Myung Sun; Kim, Chul Yong [College of Medicine, Korea University, Seoul (Korea, Republic of)

    2002-09-15

    Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. From November 1992 to March 1998, 224 patients with uterine cervical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was 45 {approx} 54 Gy (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. The local control rate (LCR) at 5 years was 80% in group A and 84% in group B ({rho} = 0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was 60.9% in group A and 76.9% in group B ({rho} = 0.2557). In post-operative radiation therapy patients, LCR at 5 years was 92.6% in group A and 91.6% in group B ({rho} 0.8867). The incidence of late complication was 18% (22 patients) and 29.4% (30 patients), of bladder complication was 9.8% (12 patients) and 14.7% (15 patients), and of rectal complication was 9.8% (12 patients) and 21.6% (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication ({rho} =0.0405) (rectal complication, {rho} = 0.0147; bladder complication, {rho} =0.115). The same result was observed in postoperative radiation therapy patients ({rho} = 0.0860) and radiation only

  2. Two fractions of high-dose-rate brachytherapy in the management of cervix cancer: clinical experience with and without chemotherapy

    International Nuclear Information System (INIS)

    Sood, Brij M.; Gorla, Giridhar; Gupta, Sajel; Garg, Madhur; Deore, Shivaji; Runowicz, Carolyn D.; Fields, Abbie L.; Goldberg, Gary L.; Anderson, Patrick S.; Vikram, Bhadrasain

    2002-01-01

    Purpose: In recent years, high-dose-rate brachytherapy has become popular in the management of carcinoma of the uterine cervix, because it eliminates many of the problems associated with low-dose-rate brachytherapy. However, the optimum time-dose-fractionation remains controversial. Two fractions of high-dose-rate brachytherapy are convenient for patients, but most radiation oncologists in the United States do not use them, because of fear that they could lead to excessive rectal or bladder toxicity. Here we present our experience, which suggests that a two-fraction regimen is indeed safe and effective. Methods: We treated 49 patients with Stages I-III biopsy-proven carcinoma of the uterine cervix by external beam radiation therapy (EBRT), plus two fractions of high-dose-rate brachytherapy. The histology was squamous cell carcinoma in 43 patients (88%) and nonsquamous in 6 (12%). The median size of the primary tumor was 6 cm (range: 3-10 cm). Each patient received EBRT to the pelvis to a median dose of 45 Gy (range: 41.4-50.4 Gy), followed by a parametrial boost when indicated. Thirty patients (61%) also received irradiation to the para-aortic lymph nodes to a dose of 45 Gy. After EBRT, each patient underwent two applications of high-dose-rate brachytherapy, 1 week apart. The dose delivered to point A was 9 Gy per application for 49 applications (50%) and 9.4 Gy for 43 applications (44%), and it varied from 7 to 11 Gy for the rest (6%). The total dose to the rectum from both high-dose-rate brachytherapy applications ranged from 4.7 to 11.7 Gy (median: 7.1 Gy), and the total dose to the bladder from 3.8 to 15.5 Gy (median: 10.5 Gy). Twenty-five of the 49 patients (51%) received concomitant chemotherapy (cisplatin 20 mg/m 2 /day for 5 days) during the first and fourth weeks of EBRT and once after the second high-dose-rate brachytherapy application. Chemotherapy was not assigned in a randomized fashion. The use of chemotherapy increased during the time period spanned

  3. Perioperative fractionated high-dose rate brachytherapy for malignant bone and soft tissue tumors

    International Nuclear Information System (INIS)

    Koizumi, Masahiko; Inoue, Takehiro; Yamazaki, Hideya; Teshima, Teruki; Tanaka, Eiichi; Yoshida, Ken; Imai, Atsushi; Shiomi, Hiroya; Kagawa, Kazufumi; Araki, Nobuto; Kuratsu, Shigeyuki; Uchida, Atsumasa; Inoue, Toshihiko

    1999-01-01

    Purpose: To investigate the viability of perioperative fractionated HDR brachytherapy for malignant bone and soft tissue tumors, analyzing the influence of surgical margin. Methods and Materials: From July 1992 through May 1996, 16 lesions of 14 patients with malignant bone and soft tissue tumors (3 liposarcomas, 3 MFHs, 2 malignant schwannomas, 2 chordomas, 1 osteosarcoma, 1 leiomyosarcoma, 1 epithelioid sarcoma, and 1 synovial sarcoma) were treated at the Osaka University Hospital. The patients' ages ranged from 14 to 72 years (median: 39 years). Treatment sites were the pelvis in 6 lesions, the upper limbs in 5, the neck in 4, and a lower limb in 1. The resection margins were classified as intracapsular in 5 lesions, marginal in 5, and wide in 6. Postoperative fractionated HDR brachytherapy was started on the 4th-13th day after surgery (median: 6th day). The total dose was 40-50 Gy/7-10 fr/ 4-7 day (bid) at 5 or 10 mm from the source. Follow-up periods were between 19 and 46 months (median: 30 months). Results: Local control rates were 75% at 1 year and 48% in 2 years, and ultimate local control was achieved in 8 (50%) of 16 lesions. Of the 8 uncontrolled lesions, 5 (63%) had intracapsular (macroscopically positive) resection margins, and all the 8 controlled lesions (100%) had marginal (microscopically positive) or wide (negative) margins. Of the total, 3 patients died of both tumor and metastasis, 3 of metastasis alone, 1 of tumor alone, and 7 showed no evidence of disease. Peripheral nerve palsy was seen in one case after this procedure, but no infection or delayed wound healing caused by tubing or irradiation has occurred. Conclusion: Perioperative fractionated HDR brachytherapy is safe, well tolerated, and applicable to marginal or wide surgical margin cases

  4. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Concomitant chemoradiotherapy with high dose rate brachytherapy as a definitive treatment modality for locally advanced cervical cancer. T Refaat, A Elsaid, N Lotfy, K Kiel, W Small Jr, P Nickers, E Lartigau ...

  5. Justification for inter-fraction correction of catheter movement in fractionated high dose-rate brachytherapy treatment of prostate cancer

    International Nuclear Information System (INIS)

    Simnor, Tania; Li, Sonia; Lowe, Gerry; Ostler, Peter; Bryant, Linda; Chapman, Caroline; Inchley, Dave; Hoskin, Peter J.

    2009-01-01

    Background and purpose: Fractionated high dose-rate (HDR) brachytherapy in the treatment of prostate cancer relies on reproducible catheter positions for each fraction to ensure adequate tumour coverage while minimising dose to normal tissues. Peri-prostatic oedema may cause caudal displacement of the catheters relative to the prostate gland between fractions. This can be corrected for by changing source dwell positions or by physical re-advancement of catheters before treatment. Materials and methods: Data for 20 consecutive monotherapy patients receiving three HDR fractions of 10.5 Gy per fraction over 2 days were analysed retrospectively. Pre-treatment CT scans were used to assess the effect of catheter movement between fractions on implant quality, with and without movement correction. Implant quality was evaluated using dosimetric parameters. Results: Compared to the first fraction (f1) the mean inter-fraction caudal movement relative to the prostate base was 7.9 mm (f2) (range 0-21 mm) and 3.9 mm (f3) (range 0-25.5 mm). PTV D90% was reduced without movement correction by a mean of 27.8% (f2) and 32.3% (f3), compared with 5.3% and 5.1%, respectively, with catheter movement correction. Dose to 2 cc of the rectum increased by a mean of 0.69 (f2) and 0.76 Gy (f3) compared with an increase of 0.03 and 0.04 Gy, respectively, with correction. The urethra V12 also increased by a mean of 0.36 (f2) and 0.39 Gy (f3) compared with 0.06 and 0.16 Gy, respectively, with correction. Conclusions: Inter-fraction correction for catheter movement using pre-treatment imaging is critical to maintain the quality of an implant. Without movement correction there is significant risk of tumour under-dosage and normal tissue over-dosage. The findings of this study justify additional imaging between fractions in order to carry out correction.

  6. Justification for inter-fraction correction of catheter movement in fractionated high dose-rate brachytherapy treatment of prostate cancer.

    Science.gov (United States)

    Simnor, Tania; Li, Sonia; Lowe, Gerry; Ostler, Peter; Bryant, Linda; Chapman, Caroline; Inchley, Dave; Hoskin, Peter J

    2009-11-01

    Fractionated high dose-rate (HDR) brachytherapy in the treatment of prostate cancer relies on reproducible catheter positions for each fraction to ensure adequate tumour coverage while minimising dose to normal tissues. Peri-prostatic oedema may cause caudal displacement of the catheters relative to the prostate gland between fractions. This can be corrected for by changing source dwell positions or by physical re-advancement of catheters before treatment. Data for 20 consecutive monotherapy patients receiving three HDR fractions of 10.5 Gy per fraction over 2 days were analysed retrospectively. Pre-treatment CT scans were used to assess the effect of catheter movement between fractions on implant quality, with and without movement correction. Implant quality was evaluated using dosimetric parameters. Compared to the first fraction (f1) the mean inter-fraction caudal movement relative to the prostate base was 7.9 mm (f2) (range 0-21 mm) and 3.9 mm (f3) (range 0-25.5 mm). PTV D90% was reduced without movement correction by a mean of 27.8% (f2) and 32.3% (f3), compared with 5.3% and 5.1%, respectively, with catheter movement correction. Dose to 2 cc of the rectum increased by a mean of 0.69 (f2) and 0.76 Gy (f3) compared with an increase of 0.03 and 0.04 Gy, respectively, with correction. The urethra V12 also increased by a mean of 0.36 (f2) and 0.39 Gy (f3) compared with 0.06 and 0.16 Gy, respectively, with correction. Inter-fraction correction for catheter movement using pre-treatment imaging is critical to maintain the quality of an implant. Without movement correction there is significant risk of tumour under-dosage and normal tissue over-dosage. The findings of this study justify additional imaging between fractions in order to carry out correction.

  7. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  8. Interstitial high-dose-rate brachytherapy boost: The feasibility and cosmetic outcome of a fractionated outpatient delivery scheme

    International Nuclear Information System (INIS)

    Manning, Matthew A.; Arthur, Douglas W.; Schmidt-Ullrich, Rupert K.; Arnfield, Mark R.; Amir, Cyrus; Zwicker, Robert D.

    2000-01-01

    Purpose: To evaluate the feasibility, potential toxicity, and cosmetic outcome of fractionated interstitial high dose rate (HDR) brachytherapy boost for the management of patients with breast cancer at increased risk for local recurrence. Methods and Materials: From 1994 to 1996, 18 women with early stage breast cancer underwent conventionally fractionated whole breast radiotherapy (50-50.4 Gy) followed by interstitial HDR brachytherapy boost. All were considered to be at high risk for local failure. Seventeen had pathologically confirmed final surgical margins of less than 2 mm or focally positive. Brachytherapy catheter placement and treatment delivery were conducted on an outpatient basis. Preplanning was used to determine optimal catheter positions to enhance dose homogeneity of dose delivery. The total HDR boost dose was 15 Gy delivered in 6 fractions of 2.5 Gy over 3 days. Local control, survival, late toxicities (LENT-SOMA), and cosmetic outcome were recorded in follow-up. In addition, factors potentially influencing cosmesis were analyzed by logistic regression analysis. Results: The minimum follow-up is 40 months with a median 50 months. Sixteen patients were alive without disease at last follow-up. There have been no in-breast failures observed. One patient died with brain metastases, and another died of unrelated causes without evidence of disease. Grade 1-2 late toxicities included 39% with hyperpigmentation, 56% with detectable fibrosis, 28% with occasional discomfort, and 11% with visible telangiectasias. Grade 3 toxicity was reported in one patient as persistent discomfort. Sixty-seven percent of patients were considered to have experienced good/excellent cosmetic outcomes. Factors with a direct relationship to adverse cosmetic outcome were extent of surgical defect (p = 0.00001), primary excision volume (p = 0.017), and total excision volume (p = 0.015). Conclusions: For high risk patients who may benefit from increased doses, interstitial HDR

  9. Brachytherapy treatment with high dose rate

    International Nuclear Information System (INIS)

    Santana Rodriguez, Sergio Marcelino; Rodriguez Rodriguez, Lissi Lisbet; Ciscal Chiclana, Onelio Alberto

    2009-01-01

    Retrospectively analyze results and prognostic factors of cervical cancer patients treated with radio concomitant cisplatin-based chemotherapy, radiation therapy combined modality. Methods: From January 2003 to December 2007, 198 patients with invasive cervical cancer were treated at the Oncology Department of Hospital Robau Celestino Hernandez (brachytherapy performed at INOR). The most common age group was 31 to 40 years. The histology in squamous cell carcinoma accounted for 84.3% of cases. The treatment consisted of external pelvic irradiation and vaginal brachytherapy, high dose rate. Concomitant chemotherapy consisted of cisplatin 40 mg/m2 weekly with a maximum of 70 mg for 5 weeks. Results: 66.2% of patients completed 5 cycles of chemotherapy. The median overall survival was 39 months, overall survival, disease-free survival and survival free of locoregional recurrence at 5 years of 78%, 76% and 78.6% respectively .. We found that clinical stage, histological type (adenocarcinoma worst outcome) were statistically related to level of response. Conclusions: Treatment with external pelvic radiation, brachytherapy and concurrent weekly cisplatin in patients with stage IIIB cervical cancer is feasible in the Chilean public health system, well tolerated and results comparable to international literature. (Author)

  10. High Dose Rate Brachytherapy in Two 9 Gy Fractions in the Treatment of Locally Advanced Cervical Cancer - a South Indian Institutional Experience.

    Science.gov (United States)

    Ghosh, Saptarshi; Rao, Pamidimukkala Bramhananda; Kotne, Sivasankar

    2015-01-01

    Although 3D image based brachytherapy is currently the standard of treatment in cervical cancer, most of the centres in developing countries still practice orthogonal intracavitary brachytherapy due to financial constraints. The quest for optimum dose and fractionation schedule in high dose rate (HDR) intracavitary brachytherapy (ICBT) is still ongoing. While the American Brachytherapy Society recommends four to eight fractions of each less than 7.5 Gy, there are some studies demonstrating similar efficacy and comparable toxicity with higher doses per fraction. To assess the treatment efficacy and late complications of HDR ICBT with 9 Gy per fraction in two fractions. This is a prospective institutional study in Southern India carried on from 1st June 2012 to 31st July 2014. In this period, 76 patients of cervical cancer satisfying our inclusion criteria were treated with concurrent chemo-radiation following ICBT with 9 Gy per fraction in two fractions, five to seven days apart. The median follow-up period in the study was 24 months (range 10.6 - 31.2 months). The 2 year actuarial local control rate, disease-free survival and overall survival were 88.1%, 84.2% and 81.8% respectively. Although 38.2% patients suffered from late toxicity, only 3 patients had grade III late toxicity. In our experience, HDR brachytherapy with 9 Gy per fraction in two fractions is an effective dose fractionation for the treatment of cervical cancer with acceptable toxicity.

  11. High dose rate brachytherapy for superficial cancer of the esophagus

    International Nuclear Information System (INIS)

    Maingon, Philippe; D'Hombres, Anne; Truc, Gilles; Barillot, Isabelle; Michiels, Christophe; Bedenne, Laurent; Horiot, Jean Claude

    2000-01-01

    Purpose: We analyzed our experience with external radiotherapy, combined modality treatment, or HDR brachytherapy alone to limited esophageal cancers. Methods and Materials: From 1991 to 1996, 25 patients with limited superficial esophagus carcinomas were treated by high dose rate brachytherapy. The mean age was 63 years (43-86 years). Five patients showed superficial local recurrence after external radiotherapy. Eleven patients without invasion of the basal membrane were staged as Tis. Fourteen patients with tumors involving the submucosa without spreading to the muscle were staged as T1. Treatment consisted of HDR brachytherapy alone in 13 patients, external radiotherapy and brachytherapy in 8 cases, and concomitant chemo- and radiotherapy in 4 cases. External beam radiation was administered to a total dose of 50 Gy using 2 Gy daily fractions in 5 weeks. In cases of HDR brachytherapy alone (13 patients), 6 applications were performed once a week. Results: The mean follow-up is 31 months (range 24-96 months). Twelve patients received 2 applications and 13 patients received 6 applications. Twelve patients experienced a failure (48%), 11/12 located in the esophagus, all of them in the treated volume. One patient presented an isolated distant metastasis. In the patients treated for superficial recurrence, 4/5 were locally controlled (80%) by brachytherapy alone. After brachytherapy alone, 8/13 patients were controlled (61%). The mean disease-free survival is 14 months (1-36 months). Overall survival is 76% at 1 year, 37% at 2 years, and 14% at 3 years. Overall survival for Tis patients is 24% vs. 20% for T1 (p 0.83). Overall survival for patients treated by HDR brachytherapy alone is 43%. One patient presented with a fistula with local failure after external radiotherapy and brachytherapy. Four stenosis were registered, two were diagnosed on barium swallowing without symptoms, and two required dilatations. Conclusion: High dose rate brachytherapy permits the treating

  12. Posttraumatic Stress Disorder After High-Dose-Rate Brachytherapy for Cervical Cancer With 2 Fractions in 1 Application Under Spinal/Epidural Anesthesia: Incidence and Risk Factors

    Energy Technology Data Exchange (ETDEWEB)

    Kirchheiner, Kathrin, E-mail: kathrin.kirchheiner@meduniwien.ac.at [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna (Austria); Czajka-Pepl, Agnieszka [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Ponocny-Seliger, Elisabeth [Department of Psychology, Sigmund Freud Private University Vienna, Vienna (Austria); Scharbert, Gisela; Wetzel, Léonore [Department of Anaesthesia, General Intensive Care and Pain Management, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Nout, Remi A. [Department of Clinical Oncology, Leiden University Medical Center, Leiden (Netherlands); Sturdza, Alina [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Dimopoulos, Johannes C. [Metropolitan Hospital, Athens (Greece); Dörr, Wolfgang; Pötter, Richard [Department of Radiation Oncology, Comprehensive Cancer Center, Medical University of Vienna/General Hospital of Vienna, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna, Vienna (Austria)

    2014-06-01

    Purpose: To investigate the psychological consequences of high-dose-rate brachytherapy with 2 fractions in 1 application under spinal/epidural anesthesia in the treatment of locally advanced cervical cancer. Methods and Materials: In 50 patients with locally advanced cervical cancer, validated questionnaires were used for prospective assessment of acute and posttraumatic stress disorder (ASD/PTSD) (Impact of Event Scale–Revision), anxiety/depression (Hospital Anxiety and Depression Scale), quality of life (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30/Cervical Cancer 24), physical functioning (World Health Organization performance status), and pain (visual analogue scale), before and during treatment and 1 week and 3 months after treatment. Qualitative interviews were recorded in open format for content analysis. Results: Symptoms of ASD occurred in 30% of patients 1 week after treatment; and of PTSD in 41% 3 months after treatment in association with this specific brachytherapy procedure. Pretreatment predictive variables explain 82% of the variance of PTSD symptoms. Helpful experiences were the support of the treatment team, psychological support, and a positive attitude. Stressful factors were pain, organizational problems during treatment, and immobility between brachytherapy fractions. Conclusions: The specific brachytherapy procedure, as performed in the investigated mono-institutional setting with 2 fractions in 1 application under spinal/epidural anesthesia, bears a considerable risk of traumatization. The source of stress seems to be not the brachytherapy application itself but the maintenance of the applicator under epidural anesthesia in the time between fractions. Patients at risk may be identified before treatment, to offer targeted psycho-social support. The patients' open reports regarding helpful experiences are an encouraging feedback for the treatment team; the reported stressful

  13. Posttraumatic Stress Disorder After High-Dose-Rate Brachytherapy for Cervical Cancer With 2 Fractions in 1 Application Under Spinal/Epidural Anesthesia: Incidence and Risk Factors

    International Nuclear Information System (INIS)

    Kirchheiner, Kathrin; Czajka-Pepl, Agnieszka; Ponocny-Seliger, Elisabeth; Scharbert, Gisela; Wetzel, Léonore; Nout, Remi A.; Sturdza, Alina; Dimopoulos, Johannes C.; Dörr, Wolfgang; Pötter, Richard

    2014-01-01

    Purpose: To investigate the psychological consequences of high-dose-rate brachytherapy with 2 fractions in 1 application under spinal/epidural anesthesia in the treatment of locally advanced cervical cancer. Methods and Materials: In 50 patients with locally advanced cervical cancer, validated questionnaires were used for prospective assessment of acute and posttraumatic stress disorder (ASD/PTSD) (Impact of Event Scale–Revision), anxiety/depression (Hospital Anxiety and Depression Scale), quality of life (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core 30/Cervical Cancer 24), physical functioning (World Health Organization performance status), and pain (visual analogue scale), before and during treatment and 1 week and 3 months after treatment. Qualitative interviews were recorded in open format for content analysis. Results: Symptoms of ASD occurred in 30% of patients 1 week after treatment; and of PTSD in 41% 3 months after treatment in association with this specific brachytherapy procedure. Pretreatment predictive variables explain 82% of the variance of PTSD symptoms. Helpful experiences were the support of the treatment team, psychological support, and a positive attitude. Stressful factors were pain, organizational problems during treatment, and immobility between brachytherapy fractions. Conclusions: The specific brachytherapy procedure, as performed in the investigated mono-institutional setting with 2 fractions in 1 application under spinal/epidural anesthesia, bears a considerable risk of traumatization. The source of stress seems to be not the brachytherapy application itself but the maintenance of the applicator under epidural anesthesia in the time between fractions. Patients at risk may be identified before treatment, to offer targeted psycho-social support. The patients' open reports regarding helpful experiences are an encouraging feedback for the treatment team; the reported stressful

  14. Treatment of the prostate cancer with high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro; Torres Silva, Felipe

    2002-01-01

    The prostate cancer treatment in early stages is controversial. The high dose rate brachytherapy has been used like monotherapy or boost with external beam radiotherapy in advanced disease. This paper describes the technique and the advantages over other modalities

  15. Favorable Preliminary Outcomes for Men With Low- and Intermediate-risk Prostate Cancer Treated With 19-Gy Single-fraction High-dose-rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Krauss, Daniel J., E-mail: dkrauss@beaumont.edu [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Ye, Hong [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro A. [21st Century Oncology, Farmington Hills, Michigan (United States); Mitchell, Beth; Sebastian, Evelyn; Limbacher, Amy; Gustafson, Gary S. [Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2017-01-01

    Purpose: To report the toxicity and preliminary clinical outcomes of a prospective trial evaluating 19-Gy, single-fraction high-dose-rate (HDR) brachytherapy for men with low- and intermediate-risk prostate cancer. Methods and Materials: A total of 63 patients were treated according to an institutional review board-approved prospective study of single-fraction HDR brachytherapy. Eligible patients had tumor stage ≤T2a, prostate-specific antigen level ≤15 ng/mL, and Gleason score ≤7. Patients with a prostate gland volume >50 cm{sup 3} and baseline American Urologic Association symptom score >12 were ineligible. Patients underwent transrectal ultrasound-guided transperineal implantation of the prostate, followed by single-fraction HDR brachytherapy. Treatment was delivered using {sup 192}Ir to a dose of 19 Gy prescribed to the prostate, with no additional margin applied. Results: Of the 63 patients, 58 had data available for analysis. Five patients had withdrawn consent during the follow-up period. The median follow-up period was 2.9 years (range 0.3-5.2). The median age was 61.4 years. The median gland volume at treatment was 34.8 cm{sup 3}. Of the 58 patients, 91% had T1 disease, 71% had Gleason score ≤6 (29% with Gleason score 7), and the median pretreatment prostate-specific antigen level was 5.1 ng/mL. The acute and chronic grade 2 genitourinary toxicity incidence was 12.1% and 10.3%, respectively. No grade 3 urinary toxicity occurred. No patients experienced acute rectal toxicity grade ≥2, and 2 experienced grade ≥2 chronic gastrointestinal toxicity. Three patients experienced biochemical failure, yielding a 3-year cumulative incidence estimate of 6.8%. Conclusions: Single-fraction HDR brachytherapy is well-tolerated, with favorable preliminary biochemical and clinical disease control rates.

  16. Dosimetry in high dose rate endoluminal brachytherapy

    International Nuclear Information System (INIS)

    Uno, Takashi; Kotaka, Kikuo; Itami, Jun

    1994-01-01

    In endoluminal brachytherapy for the tracheobronchial tree, esophagus, and bile duct, a reference point for dose calculation has been often settled at 1 cm outside from the middle of source travel path. In the current study, a change in the ratio of the reference point dose on the convex to concave side (Dq/Dp) was calculated, provided the source travel path bends as is the case in most endoluminal brachytherapies. Point source was presumed to move stepwise at 1 cm interval from 4 to 13 locations. Retention time at each location was calculated by personal computer so as to deliver equal dose at 1 cm from the linear travel path. With the retention time remaining constant, the change of Dq/Dp was assessed by bending the source travel path. Results indicated that the length of the source travel path and radius of its curve influenced the pattern of change in Dq/Dp. Therefore, it was concluded that the difference in reference dose on the convex and concave side of the curved path is not negligible under certain conditions in endoluminal brachytherapy. In order to maintain the ratio more than 0.9, relatively greater radius was required when the source travel path was decreased. (author)

  17. Six fractions per week of external beam radiotherapy and high-dose-rate brachytherapy for carcinoma of the uterine cervix: A phase I/II study

    International Nuclear Information System (INIS)

    Yoon, Sang Min; Huh, Seung Jae; Park, Won; Lee, Jeung Eun; Park, Young Je; Nam, Hee Rim; Lim, Do Hoon; Ahn, Yong Chan

    2006-01-01

    Purpose: This study evaluated the treatment results of external beam radiotherapy administered in six fractions per week and high-dose-rate (HDR) brachytherapy for the treatment of cervical cancer. Methods and Materials: From July 2000 to July 2003, 43 patients were enrolled in this study. The patients received 45 Gy from a 10-MV photon beam using four-field box or anterior-posterior beams. Parametrial regions and the pelvic side walls were boosted with up to 50.4 Gy using a midline block. The daily fraction dose was 1.8 Gy administered in six-weekly fractions, from Monday to Saturday. HDR brachytherapy was also delivered at doses of 24 Gy to point A in six fractions twice a week. The median follow-up time was 37 months (range, 9-60 months). Results: The median overall treatment time was 51 days for all patients (range, 44-62 days). Thirty-four patients (79.1%) achieved complete remission and 8 (18.6%) achieved partial remission after radiotherapy. Locoregional recurrence occurred in 5 patients (11.6%), and a distant metastasis was encountered in 6 patients (13.9%). The 3-year overall survival, locoregional, and distant metastasis-free survival rates were 74.7%, 87.8%, and 84.7%, respectively. Grade 2 and 3 late rectal complications were encountered in 3 (6.5%) and 1 (2.2%), respectively. There were no Grade 3 late bladder complications. Conclusions: Six fractions per week of external beam radiotherapy and HDR brachytherapy is an effective treatment for patients with a carcinoma of the uterine cervix and can be used as a possible alternative to concomitant chemoradiotherapy in elderly patients or in patients with co-morbidity

  18. Health-Related Quality of Life After Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Morton, Gerard C.; Loblaw, D. Andrew; Chung, Hans; Tsang, Gail; Sankreacha, Raxa; Deabreu, Andrea; Zhang Liying; Mamedov, Alexandre; Cheung, Patrick; Batchelar, Deidre; Danjoux, Cyril; Szumacher, Ewa

    2011-01-01

    Purpose: To investigate the change in health-related quality of life for men after high-dose-rate brachytherapy and external beam radiotherapy for prostate cancer and the factors associated with this change. Methods and Materials: Eligible patients had clinically localized intermediate-risk prostate cancer. The patients received high-dose-rate brachytherapy as a single 15-Gy implant, followed by external beam radiotherapy to 37.5 Gy in 15 fractions. The patients were monitored prospectively for toxicity (Common Terminology Criteria for Adverse Events, version 3.0) and health-related quality of life (Expanded Prostate Cancer Index Composite [EPIC]). The proportion of patients developing a clinically significant difference in the EPIC domain score (minimally important difference of >0.5 standard deviation) was determined and correlated with the baseline clinical and dosimetric factors. The study accrued 125 patients, with a median follow-up of 24 months. Results: By 24 months, 23% had Grade 2 urinary toxicity and only 5% had Grade 2 bowel toxicity, with no Grade 3 toxicity. The proportion of patients reporting a significant decrease in EPIC urinary, bowel, sexual, and hormonal domain scores was 53%, 51%, 45%, and 40% at 12 months and 57%, 65%, 51%, and 30% at 24 months, respectively. The proportion with a >1 standard deviation decrease in the EPIC urinary, bowel, sexual, and hormonal domain scores was 38%, 36%, 24%, and 20% at 12 months and 46%, 48%, 19%, and 8% at 24 months, respectively. On multivariate analysis, the dose to 10% of the urethra was associated with a decreasing EPIC urinary domain score (p = .0089) and, less strongly (p = .0312) with a decreasing hormonal domain score. No association was found between the prostate volume, bladder dose, or high-dose volume and urinary health-related quality of life. A high baseline International Index of Erectile Function score was associated (p = .0019) with a decreasing sexual domain score. The optimal maximal dose

  19. Fractionated perineal high-dose-rate temporary brachytherapy combined with external beam radiation in the treatment of localized prostate cancer: is lymph node sampling necessary?

    International Nuclear Information System (INIS)

    Gyorgy, Kovacs; Razvan, Galalae

    2003-01-01

    To study the influence of imaging based nodal staging and local dose escalation by a high-dose-rate brachytherapy (HDR-BT) boost in the treatment of locally confined prostate cancer in terms of prostate specific antigen (PSA) recurrence-free survival (biochemical non-evidence of disease (bNED)), treatment toxicity and prognostic variables. The prospectively recorded files of 144 men aged in a median of 68 years with a mean follow-up of 8 years (60-171 months) receiving curatively intended, transrectal ultrasound guided high-dose-rate 192-iridium-brachytherapy (HDR-BT) combined with external beam radiation therapy (EBRT) for locally confined prostate cancer were analyzed. T-stages were defined by digital rectal investigation and transrectal sonography (TRUS), nodal staging was performed with computed tomography (CT)/magnetic resonance imaging (MRI) (UICC/AJCR 1992). Twenty-nine patients (20.1%) had T1b-T2a tumors, and 115 patients had T2b-T3 tumors. Median initial PSA (iPSA) was 12.15 ng mL -1 (mean 25.61 ng mL -1 ). The total planned dose applied by external beam radiation was 50 Gy in the pelvis, and 40 Gy in the prostate by in-field-dose modification by individual compensators. The perineal, TRUS guided HDR-BT was delivered in two fractions of 15 Gy each. The target of BT boost was the peripheral zone of the prostate. The overall survival was 71.5%o and that of the disease free survival 82.6%. Freedom from distant metastases in T3 stage was 91.3%, whereas for G3 lesions, it was 88.23%. The bNED rate was 72.9%. Regarding treatment related late toxicity according to the EORTC/RTOG score, we observed grade 1, 2, 3 proctitis in 9.72%, 6.94%, 4.10% as well as grade 1, 2, 3 cystitis in 12.5%, 4.16%2.08%, respectively. Grade 4 and 5 proctitis or cystitis were not registered. The minimum 5-year and mean 8-year results confirm that local dose escalation by TRUS guided perineal HDR-BT and complementary external beam radiation of the pelvic lymphatics has curative potential

  20. Transit dose calculation in high dose rate brachytherapy (HDR ...

    African Journals Online (AJOL)

    Transit doses around a high dose rate 192Ir brachytherapy source were calculated using Sievert Integral at positions where the moving source was located exactly between two adjacent dwell positions. The correspond-ing transit dose rates were obtained by using energy absorption coefficients. Discrete step sizes of 0.25 ...

  1. High-dose-rate brachytherapy in uterine cervical carcinoma

    International Nuclear Information System (INIS)

    Patel, Firuza D.; Rai, Bhavana; Mallick, Indranil; Sharma, Suresh C.

    2005-01-01

    Purpose: High-dose-rate (HDR) brachytherapy is in wide use for curative treatment of cervical cancer. The American Brachytherapy Society has recommended that the individual fraction size be <7.5 Gy and the range of fractions should be four to eight; however, many fractionation schedules, varying from institution to institution, are in use. We use 9 Gy/fraction of HDR in two to five fractions in patients with carcinoma of the uterine cervix. We found that our results and toxicity were comparable to those reported in the literature and hereby present our experience with this fractionation schedule. Methods and Materials: A total of 121 patients with Stage I-III carcinoma of the uterine cervix were treated with HDR brachytherapy between 1996 and 2000. The total number of patients analyzed was 113. The median patient age was 53 years, and the histopathologic type was squamous cell carcinoma in 93% of patients. The patients were subdivided into Groups 1 and 2. In Group 1, 18 patients with Stage Ib-IIb disease, tumor size <4 cm, and preserved cervical anatomy underwent simultaneous external beam radiotherapy to the pelvis to a dose of 40 Gy in 20 fractions within 4 weeks with central shielding and HDR brachytherapy of 9 Gy/fraction, given weekly, and interdigitated with external beam radiotherapy. The 95 patients in Group 2, who had Stage IIb-IIIb disease underwent external beam radiotherapy to the pelvis to a dose of 46 Gy in 23 fractions within 4.5 weeks followed by two sessions of HDR intracavitary brachytherapy of 9 Gy each given 1 week apart. The follow-up range was 3-7 years (median, 36.4 months). Late toxicity was graded according to the Radiation Therapy Oncology Group criteria. Results: The 5-year actuarial local control and disease-free survival rate was 74.5% and 62.0%, respectively. The actuarial local control rate at 5 years was 100% for Stage I, 80% for Stage II, and 67.2% for Stage III patients. The 5-year actuarial disease-free survival rate was 88.8% for

  2. Single-Fraction High-Dose-Rate Brachytherapy and Hypofractionated External Beam Radiation Therapy in the Treatment of Intermediate-Risk Prostate Cancer - Long Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Cury, Fabio L., E-mail: fabio.cury@muhc.mcgill.ca [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada); Duclos, Marie [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada); Aprikian, Armen [Department of Urology, McGill University Health Centre, Montreal, QC (Canada); Patrocinio, Horacio [Department of Medical Physics, McGill University Health Centre, Montreal, QC (Canada); Kassouf, Wassim [Department of Urology, McGill University Health Centre, Montreal, QC (Canada); Shenouda, George; Faria, Sergio; David, Marc; Souhami, Luis [Department of Radiation Oncology, McGill University Health Centre, Montreal, QC (Canada)

    2012-03-15

    Purpose: We present the long-term results of a cohort of patients with intermediate-risk prostate cancer (PC) treated with single-fraction high-dose-rate brachytherapy (HDRB) combined with hypofractionated external beam radiation therapy (HypoRT). Methods and Materials: Patients were treated exclusively with HDRB and HypoRT. HDRB delivered a dose of 10 Gy to the prostate surface and HypoRT consisted of 50 Gy delivered in 20 daily fractions. The first 121 consecutive patients with a minimum of 2 years posttreatment follow-up were assessed for toxicity and disease control. Results: The median follow-up was 65.2 months. No acute Grade III or higher toxicity was seen. Late Grade II gastrointestinal toxicity was seen in 9 patients (7.4%) and Grade III in 2 (1.6%). Late Grade III genitourinary toxicity was seen in 2 patients (1.6%). After a 24-month follow-up, a rebiopsy was offered to the first 58 consecutively treated patients, and 44 patients agreed with the procedure. Negative biopsies were found in 40 patients (91%). The 5-year biochemical relapse-free survival rate was 90.7% (95% CI, 84.5-96.9%), with 13 patients presenting biochemical failure. Among them, 9 were diagnosed with distant metastasis. Prostate cancer-specific and overall survival rates at 5 years were 100% and 98.8% (95% CI, 96.4-100%), respectively. Conclusion: The combination of HDRB and HypoRT is well tolerated, with acceptable toxicity rates. Furthermore, results from rebiopsies revealed an encouraging rate of local control. These results confirm that the use of conformal RT techniques, adapted to specific biological tumor characteristics, have the potential to improve the therapeutic ratio in intermediate-risk PC patients.

  3. Urethral stricture following high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Sullivan, Lisa; Williams, Scott G.; Tai, Keen Hun; Foroudi, Farshad; Cleeve, L.; Duchesne, Gillian M.

    2009-01-01

    Purpose: To evaluate the incidence, timing, nature and outcome of urethral strictures following high dose rate brachytherapy (HDRB) for prostate carcinoma. Methods and materials: Data from 474 patients with clinically localised prostate cancer treated with HDRB were analysed. Ninety percent received HDRB as a boost to external beam radiotherapy (HDRBB) and the remainder as monotherapy (HDRBM). Urethral strictures were graded according to the Common Terminology Criteria for Adverse Events v3.0. Results: At a median follow-up of 41 months, 38 patients (8%) were diagnosed with a urethral stricture (6-year actuarial risk 12%). Stricture location was bulbo-membranous (BM) urethra in 92.1%. The overall actuarial rate of grade 2 or more BM urethral stricture was estimated at 10.8% (95% CI 7.0-14.9%), with a median time to diagnosis of 22 months (range 10-68 months). All strictures were initially managed with either dilatation (n = 15) or optical urethrotomy (n = 20). Second line therapy was required in 17 cases (49%), third line in three cases (9%) and 1 patient open urethroplasty (grade 3 toxicity). Predictive factors on multivariate analysis were prior trans-urethral resection of prostate (hazard ratio (HR) 2.81, 95% CI 1.15-6.85, p = 0.023); hypertension (HR 2.83, 95% CI 1.37-5.85, p = 0.005); and dose per fraction used in HDR (HR for 1 Gy increase per fraction 1.33, 95% CI 1.08-1.64, p = 0.008). Conclusions: BM urethral strictures are the most common late grade 2 or more urinary toxicity following HDR brachytherapy for prostate cancer. Most are manageable with minimally invasive procedures. Both clinical and dosimetric factors appear to influence the risk of stricture formation.

  4. High-Dose-Rate Brachytherapy as Monotherapy Delivered in Two Fractions Within One Day for Favorable/Intermediate-Risk Prostate Cancer: Preliminary Toxicity Data

    Energy Technology Data Exchange (ETDEWEB)

    Ghilezan, Michel, E-mail: mghilezan@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital and Rose Cancer Institute, Royal Oak, Michigan (United States); Martinez, Alvaro; Gustason, Gary; Krauss, Daniel; Antonucci, J. Vito; Chen, Peter; Fontanesi, James; Wallace, Michelle; Ye Hong; Casey, Alyse; Sebastian, Evelyn; Kim, Leonard; Limbacher, Amy [Department of Radiation Oncology, William Beaumont Hospital and Rose Cancer Institute, Royal Oak, Michigan (United States)

    2012-07-01

    Purpose: To report the toxicity profile of high-dose-rate (HDR)-brachytherapy (BT) as monotherapy in a Human Investigation Committee-approved study consisting of a single implant and two fractions (12 Gy Multiplication-Sign 2) for a total dose of 24 Gy, delivered within 1 day. The dose was subsequently increased to 27 Gy (13.5 Gy Multiplication-Sign 2) delivered in 1 day. We report the acute and early chronic genitourinary and gastrointestinal toxicity. Methods and Materials: A total of 173 patients were treated between December 2005 and July 2010. However, only the first 100 were part of the IRB-approved study and out of these, only 94 had a minimal follow-up of 6 months, representing the study population for this preliminary report. All patients had clinical Stage T2b or less (American Joint Committee on Cancer, 5th edition), Gleason score 6-7 (3+4), and prostate-specific antigen level of {<=}12 ng/mL. Ultrasound-guided HDR-BT with real-time dosimetry was used. The prescription dose was 24 Gy for the first 50 patients and 27 Gy thereafter. The dosimetric goals and constraints were the same for the two dose groups. Toxicity was scored using the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. The highest toxicity scores encountered at any point during follow-up are reported. Results: The median follow-up was 17 months (range, 6-40.5). Most patients had Grade 0-1 acute toxicity. The Grade 2 acute genitourinary toxicity was mainly frequency/urgency (13%), dysuria (5%), hematuria, and dribbling/hesitancy (2%). None of the patients required a Foley catheter at any time; however, 8% of the patients experienced transient Grade 1 diarrhea. No other acute gastrointestinal toxicities were found. The most common chronic toxicity was Grade 2 urinary frequency/urgency in 16% of patients followed by dysuria in 4% of patients; 2 patients had Grade 2 rectal bleeding and 1 had Grade 4, requiring laser treatment. Conclusions: Favorable

  5. Radiation safety program in a high dose rate brachytherapy facility

    International Nuclear Information System (INIS)

    Rodriguez, L.V.; Hermoso, T.M.; Solis, R.C.

    2001-01-01

    The use of remote afterloading equipment has been developed to improve radiation safety in the delivery of treatment in brachytherapy. Several accidents, however, have been reported involving high dose-rate brachytherapy system. These events, together with the desire to address the concerns of radiation workers, and the anticipated adoption of the International Basic Safety Standards for Protection Against Ionizing Radiation (IAEA, 1996), led to the development of the radiation safety program at the Department of Radiotherapy, Jose R. Reyes Memorial Medical Center and at the Division of Radiation Oncology, St. Luke's Medical Center. The radiation safety program covers five major aspects: quality control/quality assurance, radiation monitoring, preventive maintenance, administrative measures and quality audit. Measures for evaluation of effectiveness of the program include decreased unnecessary exposures of patients and staff, improved accuracy in treatment delivery and increased department efficiency due to the development of staff vigilance and decreased anxiety. The success in the implementation required the participation and cooperation of all the personnel involved in the procedures and strong management support. This paper will discuss the radiation safety program for a high dose rate brachytherapy facility developed at these two institutes which may serve as a guideline for other hospitals intending to install a similar facility. (author)

  6. Clinical results of iridium-192 high dose rate brachytherapy with external beam radiotherapy

    International Nuclear Information System (INIS)

    Nohara, Takahiro; Mizokami, Atsushi; Kumano, Tomoyasu

    2010-01-01

    Here, we report the clinical results of iridium-192 high dose rate brachytherapy at Kanazawa University Hospital. The study population consisted of 166 patients diagnosed with T1c-T3bN0M0 prostate cancer treated with high dose rate brachytherapy and external beam radiotherapy and followed up for 6 months or longer. Treatment consisted of external beam radiotherapy to the prostate at 44 Gy/22 fractions and high dose rate brachytherapy at 18 Gy/3 fractions. Median follow-up interval was 31.5 months (range 6.2-88.7). The overall 5-year biological recurrence-free survival rate was 93.0%. The 5-year biological recurrence-free survival rates for the patients in low-, intermediate- and high-risk groups according to the D'Amico risk classification criteria were 96.1%, 89.0% and 91.6%, respectively. When limited to the group that did not receive adjuvant hormonal therapy, the 5-year biological recurrence-free survival rates for the patients in low-, intermediate- and high-risk groups were 96.0%, 96.3% and 82.9%, respectively. Grade 3 or greater adverse effects were rare. Urethral stricture was observed in only 1.0% of the patients. Eighty percent of patients retained erectile function after high dose rate brachytherapy and reported satisfaction with sexual function. High dose rate brachytherapy is considered a good form of treatment for localized prostate cancer, although longer follow-up is necessary. (author)

  7. HIGH-DOSE RATE BRACHYTHERAPY IN CARCINOMA CERVIX STAGE IIIB

    Directory of Open Access Journals (Sweden)

    Sathya Maruthavanan

    2016-07-01

    Full Text Available INTRODUCTION Radiotherapy is the standard treatment in locally advanced (IIB-IVA and early inoperable cases. The current standard of practice with curable intent is concurrent chemoradiation in which intracavitary brachytherapy is an integral component of radiotherapy. This study aims at assessing the efficacy of HDR ICBT (High-dose rate intracavitary brachytherapy in terms local response, normal tissue reactions, and feasibility. METHODS AND MATERIALS A total of 20 patients of stage IIIB cancer of the uterine cervix were enrolled in the study and were planned to receive concurrent chemotherapy weekly along with EBRT (external beam radiotherapy to a dose of 50 Gy/25 Fr. Suitability for ICBT was assessed at 40 Gy/20 Fr. 6/20 patients were suitable at 40 Gy and received HDR ICBT with a dose of 5.5 Gy to point A in 4 sessions (5.5 Gy/4 Fr. The remaining 14/20 patients completed 50 Gy and received HDR ICBT with a dose of 6 Gy to point A in 3 sessions (6 Gy/3 Fr. RESULTS A total of 66 intracavitary applications were done and only one application required dose modification due to high bladder dose, the pelvic control rate was 85% (17/20. 10% (2/20 had stable disease and 5% (1/20 had progressive disease at one year of follow up. When toxicity was considered only 15% developed grade I and grade II rectal complications. Patient compliance and acceptability was 100%. Patients were very comfortable with the short treatment time as compared with patients on LDR ICBT (low-dose rate intracavitary brachytherapy treatment interviewed during the same period. CONCLUSION This study proves that HDR brachytherapy is efficacious and feasible in carcinoma of cervix stage IIIB. It also proves that good dose distribution can be achieved with HDR intracavitary facility by the use of dose optimization. The short treatment time in HDR ICBT makes it possible to maintain this optimised dose distribution throughout the treatment providing a gain in the therapeutic ratio and

  8. High dose rate endobronchial brachytherapy effectively palliates symptoms due to inoperable lung cancer

    International Nuclear Information System (INIS)

    Celebioglu, B.; Gurkan, O.U.; Savas, I.; Kose, K.; Kurtman, C.; Gonullu, U.; Erdogan, S.

    2002-01-01

    Intraluminal brachytherapy has become an established treatment for major airway occlusion by relapsed or persistent inoperable endobronchial tumors. The aim of this study was to compare the palliation improvement pre- and post-radiotherapy. The study group was 95 patients with the diagnosis of inoperable lung cancer who were eligible for high dose rate (HDR) brachytherapy. Fiber-optic bronchoscopy was performed and the level and degree of endobronchial obstruction were estimated in terms of bronchial obstruction index. Endobronchial irradiation was delivered using remote HDR afterloading brachytherapy with iridium-192. Brachytherapy was delivered at weeks 1, 2 and 3 at 7.5 Gy per fraction or at weeks 1 and 2 at 10 Gy per fraction. All patients were evaluated at the beginning and at the third month of therapy. Using Speiser's symptomatic scoring criteria, the severity of symptoms (dyspnea, cough, hemoptysis and postobstructive pneumonia) was weighted. Bronchoscopic findings at the initial evaluation and at the third month were also scored. Surviving patients were followed up for a minimum of 3 months with a mean of 7.5±5.35 months (median: 6 months). All the symptoms and bronchial obstruction improved significantly after brachytherapy (P 0.05). All the symptoms and bronchial obstruction index seemed to improve after brachytherapy. However, it is difficult to predict the response before the therapy. (author)

  9. Interstitial high-dose-rate brachytherapy in the treatment of base of tongue carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Takacsi-Nagy, Z.; Polgar, C.; Somogyi, A.; Major, T.; Fodor, J.; Nemeth, G. [Dept. of Radiotherapy, National Inst. of Oncology, Budapest (Hungary); Oberna, F. [Dept. of Maxillofacial Surgery, St. Rokus Hospital, Budapest (Hungary); Remenar, E.; Kasler, M. [Dept. of Head and Neck, Maxillofacial and Reconstructive Plastic Surgery, National Inst. of Oncology, Budapest (Hungary)

    2004-12-01

    Background and purpose: to date none of the studies examined the feasibility and efficacy of interstitial high-dose-rate (HDR) brachytherapy in the treatment of carcinoma of the tongue base. Therefore the aim of this study was to contribute to this issue. Patients and methods: between 1992 and 2000 37 patients (mean age 55 years) with T1-4 and NO-3 carcinoma of the base of tongue were presented. Neck dissection was carried out in twelve cases (32%). 30 patients with advanced stage received brachytherapy boost after 50-66.5 Gy (mean, 60 Gy) locoregional external beam irradiation (EBI) and 7 patients with early stage (T1-2, NO) were managed locally with wide tumor excision and sole brachytherapy. 4 of them underwent neck dissection and the others were subjected to 50 Gy regional EBI. The mean dose of boost and sole brachytherapy was 18 Gy and 28 Gy, respectively. Results: the median follow-up time for surviving patients was 51 months. The 7 sole brachytherapy patients are living with no evidence of disease. For patients treated with EBI and brachytherapy boost, the 5-year actuarial rate of local, locoregional recurrence-free and overall survival was 60%, 52% and 46%, respectively. For all patients in univariate analysis larger tumor size (T4 vs. T1-3) was significant negative predictor of local (RR: 7.23) and locoregional control (RR: 3.87), but nodal involvement was not. Delayed soft tissue ulceration and osteoradionecrosis occurred in 4 (13%) EBI and brachytherapy treated patients. None of the sole brachytherapy patients experienced severe late radiation toxicity. Conclusion: EBI combined with interstitial HDR brachytherapy boost result in acceptable local tumor control with low incidence of late side effects in patients with advanced disease. Fractionated sole HDR brachytherapy following tumor excision is a feasible treatment option for patients with early stage cancer and gives excellent local results. (orig.)

  10. Imaging method for monitoring delivery of high dose rate brachytherapy

    Science.gov (United States)

    Weisenberger, Andrew G; Majewski, Stanislaw

    2012-10-23

    A method for in-situ monitoring both the balloon/cavity and the radioactive source in brachytherapy treatment utilizing using at least one pair of miniature gamma cameras to acquire separate images of: 1) the radioactive source as it is moved in the tumor volume during brachytherapy; and 2) a relatively low intensity radiation source produced by either an injected radiopharmaceutical rendering cancerous tissue visible or from a radioactive solution filling a balloon surgically implanted into the cavity formed by the surgical resection of a tumor.

  11. High-dose-rate interstitial brachytherapy for the treatment of penile carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Petera, J.; Odrazka, K.; Zouhar, M.; Bedrosova, J.; Dolezel, M. [Dept. of Oncology and Radiotherapy, Charles Univ. Medical School and Teaching Hospital, Hradec Kralove (Czech Republic)

    2004-02-01

    Background: interstitial low-dose-rate (LDR) brachytherapy allows conservative treatment of T1-T2 penile carcinoma. High-dose-rate (HDR) is often considered to be dangerous for interstitial implants because of a higher risk of complications, but numerous reports suggest that results may be comparable to LDR. Nevertheless, there are no data in the literature available regarding HDR interstitial brachytherapy for carcinoma of the penis. Case report: a 64-year-old man with T1 NO MO epidermoid carcinoma of the glans is reported. Interstitial HDR brachytherapy was performed using the stainless hollow needle technique and a breast template for fixation and good geometry. The dose delivered was 18 x 3 Gy twice daily. Results: after 232 days from brachytherapy, the patient was without any evidence of the tumor, experienced no serious radiation-induced complications, and had a fully functional organ. Conclusion: HDR interstitial brachytherapy is feasible in selected case of penis carcinoma, when careful planning and small single fractions are used. (orig.)

  12. Clinical outcome of high-dose-rate interstitial brachytherapy in patients with oral cavity cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Uk; Cho, Kwan Ho; Moon, Sung Ho; Choi, Sung Weon; Park, Joo Yong; Yun, Tak; Lee, Sang Hyun; Lim, Young Kyung; Jeong, Chi Young [National Cancer Center, Goyang (Korea, Republic of)

    2014-12-15

    To evaluate the clinical outcome of high-dose-rate (HDR) interstitial brachytherapy (IBT) in patients with oral cavity cancer. Sixteen patients with oral cavity cancer treated with HDR remote-control afterloading brachytherapy using 192Ir between 2001 and 2013 were analyzed retrospectively. Brachytherapy was administered in 11 patients as the primary treatment and in five patients as salvage treatment for recurrence after the initial surgery. In 12 patients, external beam radiotherapy (50-55 Gy/25 fractions) was combined with IBT of 21 Gy/7 fractions. In addition, IBT was administered as the sole treatment in three patients with a total dose of 50 Gy/10 fractions and as postoperative adjuvant treatment in one patient with a total of 35 Gy/7 fractions. The 5-year overall survival of the entire group was 70%. The actuarial local control rate after 3 years was 84%. All five recurrent cases after initial surgery were successfully salvaged using IBT +/- external beam radiotherapy. Two patients developed local recurrence at 3 and 5 months, respectively, after IBT. The acute complications were acceptable (< or =grade 2). Three patients developed major late complications, such as radio-osteonecrosis, in which one patient was treated by conservative therapy and two required surgical intervention. HDR IBT for oral cavity cancer was effective and acceptable in diverse clinical settings, such as in the cases of primary or salvage treatment.

  13. Current situation of high-dose-rate brachytherapy for cervical cancer in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rogerio Matias Vidal da; Souza, Divanizia do Nascimento, E-mail: rmv.fisica@gmail.com [Universidade Federal de Sergipe (UFS), Sao Cristovao, SE (Brazil); Pinezi, Juliana Castro Dourado [Pontificia Universidade Catolica de Goias (PUC-Goias), Goiania, GO (Brazil); Macedo, Luiz Eduardo Andrade [Hospital Chama, Arapiraca, AL (Brazil)

    2014-05-15

    To assess the current situation of high-dose-rate (HDR) brachytherapy for cancer of the cervix in Brazil, regarding apparatuses, planning methods, prescription, fractionation schedule and evaluation of dose in organs at risk. Materials and methods: in the period between March/2012 and May/2013, a multiple choice questionnaire was developed and sent to 89 Brazilian hospitals which perform HDR brachytherapy. Results: sixty-one services answered the questionnaire. All regions of the country experienced a sharp increase in the number of HDR brachytherapy services in the period from 2001 to 2013. As regards planning, although a three-dimensional planning software was available in 91% of the centers, conventional radiography was mentioned by 92% of the respondents as their routine imaging method for such a purpose. Approximately 35% of respondents said that brachytherapy sessions are performed after teletherapy. The scheme of four 7 Gy intracavitary insertions was mentioned as the most frequently practiced. Conclusion: the authors observed that professionals have difficulty accessing adjuvant three-dimensional planning tools such as computed tomography and magnetic resonance imaging. (author)

  14. Novel Use of the Contura for High Dose Rate Cranial Brachytherapy

    International Nuclear Information System (INIS)

    Scanderbeg, Daniel J.; Alksne, John F.; Lawson, Joshua D.; Murphy, Kevin T.

    2011-01-01

    A popular choice for treatment of recurrent gliomas was cranial brachytherapy using the GliaSite Radiation Therapy System. However, this device was taken off the market in late 2008, thus leaving a treatment void. This case study presents our experience treating a cranial lesion for the first time using a Contura multilumen, high-dose-rate (HDR) brachytherapy balloon applicator. The patient was a 47-year-old male who was diagnosed with a recurrent right frontal anaplastic oligodendroglioma. Previous radiosurgery made him a good candidate for brachytherapy. An intracavitary HDR balloon brachytherapy device (Contura) was placed in the resection cavity and treated with a single fraction of 20 Gy. The implant, treatment, and removal of the device were all completed without incident. Dosimetry of the device was excellent because the dose conformed very well to the target. V90, V100, V150, and V200 were 98.9%, 95.7%, 27.2, and 8.8 cc, respectively. This patient was treated successfully using the Contura multilumen balloon. Contura was originally designed for deployment in a postlumpectomy breast for treatment by accelerated partial breast irradiation. Being an intracavitary balloon device, its similarity to the GliaSite system makes it a viable replacement candidate. Multiple lumens in the device also make it possible to shape the dose delivered to the target, something not possible before with the GliaSite applicator.

  15. Interstitial high dose rate brachytherapy for cancer of the oral tongue

    International Nuclear Information System (INIS)

    Nishimura, Tetsuo; Nozue, Masashi; Suzuki, Kazunori; Imai, Michiko; Iijima, Mitsuharu; Kaneko, Masao

    1997-01-01

    Between October 1992 and March 1996, 34 patients with cancer of the tongue without nodal metastases underwent fractionated interstitial brachytherapy with a high dose rate (HDR) iridium remote afterloader. The types of treatment consisted of brachytherapy (BT) alone: 8 cases, BT after surgery: 3 cases, BT after systemic chemotherapy: 3 cases, BT after arterial infusion (AI): 14 cases, BT after external beam radiotherapy (ERT): 5 cases, and BT after AI+ERT: 1 case. Applicators were implanted under general anesthesia. Reference dose was estimated at point 5 mm from source. Brachytherapy was carried out in 10 fractions twice a day for 5 days. Patients received 60 Gy with BT alone, 45-55 Gy after ERT, and 50-55 Gy after chemotherapy. Local failure was found in 5 cases with T2 lesions. Recurrence occurred in 5 out of 27 cases with tumor thickness of 10 mm or less. On the other hand, there were no recurrences in 7 cases with tumor thickness of more than 10 mm. Among various types of treatment, BT following systemic chemotherapy or AI exhibited better results (local failure: 1/17) than other modalities. Lymph node metastases appeared in 11 cases. Cause specific survival was 91% at 2 years in all cases. Ulcerations of the tongue were noted in 7 in 26 evaluable cases. Although ulceration occurred in 6/13 cases treated until March 1994, the incidence decreased to 1/13 afterwards. Careful implantation and dose prescription contributed to the decrease in ulceration. Ulcerative lesions healed with conservative care within 6 months in all cases. Bone exposure occurred in 2 cases that received 60 Gy following AI for advanced diseases. HDR fractionated brachytherapy may be a workable alternative to LDR therapy for cancer of the tongue. Brachytherapy following chemotherapy can be applied to more advanced cases of the disease. (K.H.)

  16. Current status of high dose rate brachytherapy in cervical cancer in Korea and optimal treatment schedule

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Seung Jae [College of Medicine, Sungkyunkwan Univ., Seoul (Korea, Republic of)

    1998-12-01

    Brachytherapy is an essential part of radiotherapy for uterine cervical cancer. The low dose rate (LDR) regimen has been the major technique of intracavitary therapy for cervical cancer. However, there has been an expansion in the last 20 years of high dose rate (HDR) machines using Ir-192 sources. Since 1979, HDR brachytherapy has been used for the treatment of uterine cervical cancer in Korea. The number of institutions employing HDR has been increasing, while the number of low dose rate system has been constant. In 1995, there was a total 27 HDR brachytherapy units installed and 1258 cases of patients with cervical cancer were treated with HDR. Most common regimens of HDR brachytherapy are total dose of 30-39 Gy at point A with 10-13 fractions in three fractions per week, 24-32 Gy with 6-8 fractions in two fractions per week, and 30-35 Gy with 6-7 fractions in two fractions per week. The average fractionation regimen of HDR brachytherapy is about 8 fractions of 4. 1 Gy each to point A. In Korea, treatment results for HDR brachytherapy are comparable with the LDR series and appears to be a safe and effective alternative to LDR therapy for the treatment of cervical carcinoma. Studies from the major centers report the five-year survival rate of cervical cancer as, 78-86% for Stage I, 68-85% for stage II, and 38-56% for Stage III. World-wide questionnaire study and Japanese questionnaire survey of multiple institutions showed no survival difference in any stages and dose-rate effect ratio (HDR/LDR) was calculated to be 0.54 to 0.58. However, the optimum treatment doses and fractionation schemes appropriate to generate clinical results comparable to conventional LDR schemes have yet to be standardized. In conclusion, HDR intracavitary radiotherapy is increasingly practiced in Korea and an effective treatment modality for cervical cancer. To determine the optimum radiotherapy dose and fractionation schedule, a nation-wide prospective study is necessary in Korea. In

  17. Evaluation of functioning of high dose rate brachytherapy at the Instituto Nacional do Cancer

    International Nuclear Information System (INIS)

    Guedes, Laura M.A.; Barreto, Rodrigo V.; Silva, Penha M.; Macedo, Afranio A.; Borges, Solange C.; Martinez, Valeria P.O.

    2001-01-01

    Quality control tests are very useful tools to assure the quality of patient's treatment. A daily control of the high dose rate micro selectron was performed based on the security parameters of the equipment and on the quickness of performance. The purpose of this report is to evaluate and to discuss the errors found during the first three years with the high dose rate brachytherapy, at the Instituto Nacional de Cancer. (author)

  18. Brachytherapy. High dose rate brachytherapy - Radiation protection: medical sheet ED 4287

    International Nuclear Information System (INIS)

    Celier, D.; Aubert, B.; Vidal, J.P.; Biau, A.; Lahaye, T.; Gauron, C.; Barret, C.; Boisserie, G.; Branchet, E.; Gambini, D.; Gondran, C.; Le Guen, B.; Guerin, C.; Nguyen, S.; Pierrat, N.; Sarrazin, T.; Donnarieix, D.

    2010-02-01

    After having indicated the required authorization to implement brachytherapy techniques, this document presents the various aspects and measures related to radiation protection when performing high-dose-rate brachytherapy treatments. It presents the concerned personnel, describes the operational process, indicates the associated hazards and the risk related to ionizing radiation, and describes how the risk is to be assessed and how exposure levels are to be determined (elements of risk assessment, delimitation of controlled and monitored areas, personnel classification, and choice of the dose monitoring method). It describes the various components of a risk management strategy (risk reduction, technical measures regarding the installation and the personnel, training and information, prevention and medical monitoring). It briefly presents how risk management is to be assessed, and mentions other related risks (biological risk, handling and posture, handling of heavy loads, mental workload, chemical risk)

  19. High dose rate brachytherapy using molds after chemoradiotherapy for oral cavity cancer

    International Nuclear Information System (INIS)

    Chatani, Masashi; Tsuboi, Kazuki; Yagi, Masayuki; Fujiwara, Kanta; Tachimoto, Rika; Yoshioka, Hideo

    2012-01-01

    The aim of this study was to investigate the role of the combined use of customized molds and a high dose rate (HDR) remote afterloading brachytherapy apparatus with a 192 Ir microsource in the treatment of superficial oral carcinomas after chemoradiotherapy. Nine patients with oral squamous cell carcinoma who were treated using this combined technique were analyzed retrospectively. The primary sites of the tumors were the mouth floor, gingiva, and soft palate. For each patient, a customized mold was fabricated in which 2-3 afterloading catheters were placed for the 192 Ir source. Three to eight fractions of 3 Gy, 5 mm below the mold surface, were given following external radiotherapy of 24-50 Gy/2 Gy combined with chemotherapy (peplomycin or taxotere). The total dose of HDR brachytherapy ranged from 9 to 24 Gy. The 2-year local control probability was 100% and the 2-year cause-specific survival rate was 100%. No serious complications (id est (i.e.), ulcer or bone exposure) have been observed thus far during the follow-up period of 29-120 months. HDR brachytherapy using the mold technique after chemoradiotherapy is a safe and excellent method for selected early and superficial oral cavity cancers. (author)

  20. Custom-made micro applicators for high-dose-rate brachytherapy treatment of chronic psoriasis

    Directory of Open Access Journals (Sweden)

    Ivan M. Buzurovic

    2017-06-01

    Full Text Available Purpose: In this study, we present the treatment of the psoriatic nail beds of patients refractory to standard therapies using high-dose-rate (HDR brachytherapy. The custom-made micro applicators (CMMA were designed and constructed for radiation dose delivery to small curvy targets with complicated topology. The role of the HDR brachytherapy treatment was to stimulate the T cells for an increased immune response. Material and methods: The patient diagnosed with psoriatic nail beds refractory to standard therapies received monthly subunguinal injections that caused significant pain and discomfort in both hands. The clinical target was defined as the length from the fingertip to the distal interphalangeal joint. For the accurate and reproducible setup in the multi-fractional treatment delivery, the CMMAs were designed. Five needles were embedded into the dense plastic mesh and covered with 5 mm bolus material for each micro applicator. Five CMMAs were designed, resulting in the usage of 25 catheters in total. Results: The prescription dose was planned to the depth of the anterior surface of the distal phalanx, allowing for the sparing of the surrounding tissue. The total number of the active dwell positions was 145 with step size of 5 mm. The total treatment time was 115 seconds with a 7.36 Ci activity of the 192Ir source. The treatment resulted in good pain control. The patient did not require further injections to the nail bed. After this initial treatment, additional two patients with similar symptoms received HDR brachytherapy. The treatment outcome was favorable in all cases. Conclusions : The first HDR brachytherapy treatment of psoriasis of the nail bed is presented. The initial experience revealed that brachytherapy treatment was well-tolerated and resulted in adequate control of the disease. A larger cohort of patients will be required for additional conclusions related to the long-term clinical benefits.

  1. High-dose-rate brachytherapy in the treatment of skin Kaposi sarcoma

    Directory of Open Access Journals (Sweden)

    María Ángeles González Ruiz

    2017-12-01

    Full Text Available Purpose : The aim of the study is to review our experience in treatment of Kaposi sarcoma (KS lesions with high-dose-rate (HDR brachytherapy. Material and methods : We present five new KS lesions (three patients that were treated in our hospital from May 2016 to February 2017 with HDR brachytherapy using Valencia applicators. The treatment was delivered in 5 Gy fractions over five sessions, on alternate days. Total dose of 25 Gy (EQD2 31.25 Gy was delivered. All patients were male, Caucasian, without a history of HIV, organ transplantation, or current immunosuppressive therapy. The median age was 76 years. Results : All lesions (100% were located in lower limbs (60% in the ankle, 20% in the leg, and 20% in the foot, and their development was progressive. No lesion was greater than 2 cm (range, 0.5-1.5 cm. With a median follow-up of 15 months, all patients had a complete response to the treatment, with no evidence of local recurrence or tumor progression. Most of the patients (80% had no acute toxicity; only one patient developed erythema grade 2. Conclusions : HDR brachytherapy could be a good option of treatment for these types of lesions, especially in elderly patients, or when cosmetic results are not good after surgery. Brachytherapy with the Valencia applicator, using hypofractionated regimen provides excellent results in terms of cosmetic and local control, and furthermore, facilitates treatment compliance, which is very relevant in elderly patients. HDR brachytherapy offers a simple, safe, quick, and attractive non-surgical treatment option.

  2. Salvage high-dose-rate brachytherapy for local prostate cancer recurrence after radical radiotherapy

    Directory of Open Access Journals (Sweden)

    V. A. Solodkiy

    2016-01-01

    Full Text Available Studies salvage interstitial radiation therapy for recurrent prostate cancer, launched at the end of the XX century. In recent years, more and more attention is paid to high-dose-rate brachytherapy (HDR-BT as a method of treating local recurrence.The purpose of research – preliminary clinical results of salvage high-dose-rate brachytherapy applied in cases of suspected local recurrence or of residual tumour after radiotherapy.Preliminary findings indicate the possibility of using HDR-BT, achieving local tumor control with low genitourinary toxicity.

  3. The American Brachytherapy Society recommendations for high-dose-rate brachytherapy for head-and-neck carcinoma

    International Nuclear Information System (INIS)

    Nag, Subir; Cano, Elmer R.; Demanes, D. Jeffrey; Puthawala, Ajmel A.; Vikram, Bhadrasain

    2001-01-01

    Purpose: To develop recommendations for use of high-dose-rate (HDR) brachytherapy in patients with head-and-neck cancer. Methods: A panel consisting of members of the American Brachytherapy Society (ABS) performed a literature review, added information based upon their clinical experience, and formulated recommendations for head-and-neck HDR brachytherapy. Results: The ABS recommends the use of brachytherapy as a component of the treatment of head-and-neck tumors. However, the ABS recognizes that some radiation oncologists are reluctant to employ brachytherapy in the head-and-neck region because of the complexity of the postoperative management and concerns about radiation safety. In this regard, HDR eliminates unwanted radiation exposure and thereby permits unrestricted delivery of clinical care to these brachytherapy patients. The ABS made specific recommendations for previously untreated and recurrent head-and-neck cancer patients on patient selection criteria, implant techniques, target volume definition, and HDR treatment parameters (such as time, dose, and fractionation schedules). Suggestions were provided for treatment with HDR alone and in combination with external beam radiation therapy. It should be recognized that only limited experiences exist with HDR brachytherapy in patients with head-and-neck cancers. Therefore, some of these suggested doses have not been extensively tested in clinical practice. Hence, these guidelines will be updated as significant new outcome data are available. Any clinician following these guidelines is expected to use clinical judgment to determine an individual patient's treatment. Conclusions: Little has been published in the clinical literature on HDR brachytherapy in head-and-neck cancer. Based upon the available information and the clinical experience of the panel members, general and site-specific recommendations were offered. Areas for further investigations were identified

  4. Braquiterapia de alta taxa de dose no Brasil High-dose rate brachytherapy in Brazil

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2004-10-01

    Full Text Available A braquiterapia de alta taxa de dose foi introduzida em nosso meio em janeiro de 1991. Desde então, houve uma mudança significativa na abordagem das neoplasias malignas em relação às vantagens do novo método, e também resolução da demanda reprimida de braquiterapia para as neoplasias ginecológicas. Nos primeiros dez anos de atividade, o Brasil tratou, em 31 serviços, 26.436 pacientes com braquiterapia, sendo mais de 50% das pacientes portadoras de neoplasias do colo uterino. Este estudo mostra o número e o perfil de pacientes tratados com esse método e a sua distribuição no território nacional, deixando explícito o benefício da braquiterapia de alta taxa de dose para o Brasil.High-dose rate brachytherapy was first introduced in Brazil in January 1991. Significant changes in the management of malignant neoplasms were observed since utilization of high-dose rate brachytherapy. The high number of gynecological patients awaiting for brachytherapy also decreased during this period. In the first ten years 26,436 patients were treated with high-dose rate brachytherapy. More than 50% of these patients presented neoplasms of the uterine cervix. In this study we present the number and profile of the patients treated with high-dose rate brachytherapy as well as the distribution of these patients in the Brazilian territory, proving the benefit of the use of high-dose rate brachytherapy in Brazil.

  5. High-dose-rate intracavitary brachytherapy (HDR-IC) in treatment of cervical carcinoma: 5-year results and implication of increased low-grade rectal complication on initiation of an HDR-IC fractionation scheme

    International Nuclear Information System (INIS)

    Wang Chongjong; Wan Leung, Stephen; Chen Huichun; Sun Limin; Fang Fumin; Changchien Chanchao; Huang Engyen; Wu Jiaming; Chen Chuhnchih

    1997-01-01

    Purpose: To report the treatment results and rectal/bladder complications of cervical carcinoma radically treated with high-dose-rate intracavitary brachytherapy (HDR-IC). The current policy of using three-fraction scheme was examined. Methods and Materials: Between November 1987 and August 1990, 173 patients with cervical carcinoma were treated with curative-intent radiation therapy. Whole pelvic irradiation was administered with 10-MV X ray. Dose to the central cervix was 40-44 Gy in 20-22 fractions, following by pelvic wall boost 6-14 Gy in three to seven fractions with central shielding. 60 Co sources were used for HDR-IC, and 7.2 Gy was given to Point A for three applications, 1-2 weeks apart. Duration of follow-up was 5-7.8 years. Results: Twenty-eight patients (16%) developed central-regional recurrences. Overall 5-year actuarial pelvic control rate was 83%. By stage, 5-year actuarial pelvic control rates were 94%, 87%, and 72% for Stages IB + IIA, IIB + IIIA, and IIIB + IVA, respectively. Thirty-one patients (18%) developed distant metastasis. Overall 5-year actuarial survival rate was 58%. By stage, 5-year actuarial survival rates were 79%, 59%, and 41% for Stages IB + IIA, IIB + IIIA, and IIIB + IVA, respectively. Sixty-six (38%) and 19 patients (11%) developed rectal and bladder complications, respectively. For rectal complication, the overall actuarial rate was 38% at 5 years. By grade, 5-year actuarial rectal complication rates were 24%, 15%, 4%, and 3% for Grades 1-4, respectively. Overall prevalence of rectal complications was 37% and 14% at 2 and 5 years, respectively. Prevalence of low-grade rectal complication (Grades 1 and 2) was dominant at 2 years (30%), but declined to 8% at 5 years. Prevalence of high-grade, severe rectal complication (Grades 3 and 4) remained steady at 2 and 5 years (7% and 6%, respectively). Five-year actuarial bladder complication was 9%. Five-year prevalence of bladder complication was 2%. Conclusion: Using a three-fraction

  6. Computed tomography-based treatment planning for high-dose-rate brachytherapy using the tandem and ring applicator: influence of applicator choice on organ dose and inter-fraction adaptive planning

    Directory of Open Access Journals (Sweden)

    Vishruta A. Dumane

    2017-06-01

    Full Text Available Three dimensional planning for high-dose-rate (HDR brachytherapy in cervical cancer has been highly recommended by consensus guidelines such as the American Brachytherapy Society (ABS and the Groupe Européen de Curiethérapie – European Society for Radiotherapy and Oncology (GEC-ESTRO. In this document, we describe our experience with computed tomography (CT-based planning using the tandem/ring applicator. We discuss the influence of applicator geometry on doses to organs at risk (OARs, namely the bladder, rectum, and sigmoid. Through example cases with dose prescribed to point A, we demonstrate how adaptive planning can help achieve constraints to the OARs as per guidelines.

  7. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Fox, C. D.; Kron, T.; Leahy, M.; Duchesne, G.; Williams, S.; Tai, K. H.; Haworth, A.; Herschtal, A.; Foroudi, F.

    2011-01-01

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

  8. Interfraction patient motion and implant displacement in prostate high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Fox, C. D.; Kron, T.; Leahy, M.; Duchesne, G.; Williams, S.; Tai, K. H.; Haworth, A.; Herschtal, A.; Foroudi, F. [Department of Physical Sciences, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Nursing Service, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Department of Radiation Oncology, Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Victoria 3002 (Australia); Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Insititute of Technology, Melbourne, Victoria 3000 (Australia); Department of Biostatistics and Clinical Trials, Peter MacCallum Cancer Centre, Melbourne, Victoria 3002 (Australia); Department of Radiation Oncology, Peter MacCallum Cancer Centre and University of Melbourne, Melbourne, Victoria 3010 (Australia)

    2011-11-15

    Purpose: To quantify movement of prostate cancer patients undergoing treatment, using an in-house developed motion sensor in order to determine a relationship between patient movement and high dose rate (HDR) brachytherapy implant displacement. Methods: An electronic motion sensor was developed based on a three axis accelerometer. HDR brachytherapy treatment for prostate is delivered at this institution in two fractions 24 h apart and 22 patients were monitored for movement over the interval between fractions. The motion sensors functioned as inclinometers, monitoring inclination of both thighs, and the inclination and roll of the abdomen. The implanted HDR brachytherapy catheter set was assessed for displacement relative to fiducial markers in the prostate. Angle measurements and angle differences over a 2 s time base were binned, and the standard deviations of the resulting frequency distributions used as a metric for patient motion in each monitored axis. These parameters were correlated to measured catheter displacement using regression modeling. Results: The mean implant displacement was 12.6 mm in the caudal direction. A mean of 19.95 h data was recorded for the patient cohort. Patients generally moved through a limited range of angles with a mean of the exception of two patients who spent in excess of 2 h lying on their side. When tested for a relationship between movement in any of the four monitored axes and the implant displacement, none was significant. Conclusions: It is not likely that patient movement influences HDR prostate implant displacement. There may be benefits to patient comfort if nursing protocols were relaxed to allow patients greater freedom to move while the implant is in situ.

  9. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO)

    International Nuclear Information System (INIS)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-01-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  10. High dose rate interstitial brachytherapy with external beam irradiation for localized prostate cancer. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Hiratsuka, Junichi; Jo, Yoshimasa; Yoden, Eisaku; Tanaka, Hiroyoshi; Imajo, Yoshinari [Kawasaki Medical School, Kurashiki, Okayama (Japan); Nagase, Naomi; Narihiro, Naomasa; Kubota, Juichi

    2000-12-01

    This study was undertaken to assess the biochemical and pathological results of combined external beam radiotherapy and high dose rate Ir-192 brachytherapy (HDR-Ir192) for clinically localized prostate cancer. Between October 1997 and August 1999, 39 evaluable patients with adenocarcinoma of prostate diagnosed by biopsy were treated with interstitial and external beam irradiation. Patients ranged in age from 58-82 years, with a mean of 69.7 years. T1c, T2 and T3 tumors, according to the UICC classification system (1997), were found in 7, 21 and 11 cases respectively. The mean initial pre-treatment PSA was 35.9 ng/ml (median 13.2), with 77% of the patients having had a pre-treatment PSA greater than 10 ng/ml. Of all patients, 17 had received pre-treatment hormonal therapy. Hormonal pretreatment was stopped at the beginning of radiotherapy in all cases. External beam four-field box irradiation was given to the small pelvis to a dose of 45 Gy/25 fractions. Three HDR-Ir192 treatments were given over a 30-h period, with 5.5 Gy per fraction at the circumference of the prostate gland over the course of this study. Biochemical failure was defined as a PSA level >1.5 ng/ml and rising on three consecutive values. If serial post-treatment PSA levels showed a continuous downward trend, failure was not scored. The patient with clinical evidence of progression was classified as a clinical failure. The median follow-up at the time of evaluation was 19.6 months. A post-treatment PSA level {<=}1.0 ng/ml was seen in 26 (67%) patients, and values from >1.0 to {<=}2.0 ng/ml were seen in 10 (26%) patients. Biochemical failure was not seen in 38 patients except for one patient who developed a distant bone metastasis with negative prostatic biopsy 15 months after treatment. Biochemical control rate was 100% (38/38) except for the patient with bone metastasis classified as clinical failure. Negative biopsies 18 months after treatment were found in 93% (14/15) of patients. Only one patient

  11. Treatment of regional cutaneous nodular metastases from melanoma using high-dose rate mould brachytherapy.

    Science.gov (United States)

    Chaudhuri, Anupam; De-Groot, Charles; Seel, Matthew; Jolly, Mike; Cameron, Tina

    2011-04-01

    The involvement of a wide body surface area by regional cutaneous nodular metastases (RCNM) from melanoma poses a significant therapeutic challenge. We report our experience from Waikato Hospital, Hamilton, New Zealand in successfully treating this condition with high-dose rate (HDR) surface mould brachytherapy (BT). We analysed six patients who had surgery and then developed RCNM, which was treated in our department by HDR mould BT using Iridium 192. Five out of six patients were treated with a dose of 30 Gy in five fractions to wide field with a further 6 Gy boost to tumour nodules. Our first patient received a higher dose of 36 Gy in six fractions followed by 6 Gy boost to tumour nodules. All patients experienced a complete response (CR). Median follow up was 23 months and side effects were minimal, only Radiation Therapy Oncology Group (RTOG) grade I/II early and late toxicity. To date, no in-field recurrence has been observed. Two patients died from metastatic disease at 33 and 34 months of follow up. There was a CR in all cases without in-field recurrence. To our knowledge, this is the first reported experience in treating skin melanoma with a BT surface mould. We recommend that BT surface mould should be considered when treating patients with RCNM. © 2011 The Authors. Journal of Medical Imaging and Radiation Oncology © 2011 The Royal Australian and New Zealand College of Radiologists.

  12. Treatment of regional cutaneous nodular metastases from melanoma using high-dose rate mould brachytherapy

    International Nuclear Information System (INIS)

    Chaudhuri, Anupam; De-Groot, Charles; Seel, Matthew; Jolly, Mike; Cameron Tina

    2011-01-01

    Full text: The involvement of a wide body surface area by regional cuta neous nodular metastases (RCNM) from melanoma poses a significant thera peutic challenge. We report our experience from Waikato Hospital, Hamilton, New Zealand in successfully treating this condition with high-dose rate (HDR) surface mould brachytherapy (BT). Methods: We analysed six patients who had surgery and then developed RCNM, which was treated in our department by HDR mould BT using Iridium 192. Five out of six patients were treated with a dose of 30 Gy in five fractions to wide field with a further 6 Gy boost to tumour nodules. Our first patient received a higher dose of 36 Gy in six fractions followed by 6 Gy boost to tumour nodules. Results: All patients experienced a complete response (CR). Median follow up was 23 months and side effects were minimal, only Radiation Therapy Oncol ogy Group (RTOG) grade I/ll early and late toxicity. To date, no in-field recurrence has been observed. Two patients died from metastatic disease at 33 and 34 months of follow up. Conclusion: There was a CR in all cases without in-field recurrence. To our knowledge, this is the first reported experience in treating skin melanoma with a BT surface mould. We recommend that BT surface mould should be considered when treating patients with RCNM.

  13. Radiation proctitis after the high dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Kitano, Masashi; Katsumata, Tomoe; Satoh, Takefumi

    2006-01-01

    We reviewed the medical records of 12 patients treated for rectal bleeding after high-dose rate brachytherapy for prostate cancer. All patients developed grade 2 proctitis according to the Common Terminology Criteria for Adverse Events (CTCAC) and no patients needed blood transfusion. The patients were treated with argon plasma coagulation (APC) and/or steroid suppositories. The bleeding stopped or improved in 11 patients. Although re-bleeding was noticed in 7 patients the same treatment was effective in 5 patients. (author)

  14. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Directory of Open Access Journals (Sweden)

    Antônio Cássio Assis Pellizzon

    2016-06-01

    Full Text Available Abstract For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy.

  15. Salvage high-dose-rate interstitial brachytherapy for locally recurrent rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis, E-mail: acapellizzon@hcancer.org.br [A.C. Camargo Cancer Center, Sao Paulo, SP (Brazil). Departamento de Radioterapia

    2016-05-15

    For tumors of the lower third of the rectum, the only safe surgical procedure is abdominal-perineal resection. High-dose-rate interstitial brachytherapy is a promising treatment for local recurrence of previously irradiated lower rectal cancer, due to the extremely high concentrated dose delivered to the tumor and the sparing of normal tissue, when compared with a course of external beam radiation therapy. (author)

  16. High dose-rate brachytherapy source position quality assurance using radiochromic film

    International Nuclear Information System (INIS)

    Evans, M.D.C.; Devic, S.; Podgorsak, E.B.

    2007-01-01

    Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance

  17. Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Rai, Bhavana [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Patel, Firuza D., E-mail: firuzapatel@gmail.com [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Chakraborty, Santam; Sharma, Suresh C.; Kapoor, Rakesh [Department of Radiotherapy and Oncology, Regional Cancer Centre, Postgraduate Institute of Medical Education and Research, Chandigarh (India); Aprem, Abi Santhosh [Corporate R and D Division, HLL Lifecare Limited, Karamana, Trivandrum (India)

    2013-04-01

    Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of

  18. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids: Feasibility and Early Results

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Ping, E-mail: ping.jiang@uksh.de [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Baumann, René [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Dunst, Juergen [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Department of Radiation Oncology, University of Copenhagen, Copenhagen (Denmark); Geenen, Matthias [Department of Reconstructive Surgery, Lubinus Clinic Kiel, Kiel (Germany); Siebert, Frank-André [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Niehoff, Peter [Department of Radiation Oncology, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany); Department of Radiation Oncology, Community Clinic Köln, Köln (Germany); Department of Radiation Oncology, University Witten/Herdecke, Witten (Germany); Bertolini, Julia; Druecke, Daniel [Department of Reconstructive Surgery, University Clinic Schleswig-Holstein, Campus Kiel, Kiel (Germany)

    2016-03-01

    Purpose: To prospectively evaluate high-dose-rate brachytherapy in the treatment of therapy-resistant keloids and report first results, with emphasis on feasibility and early treatment outcome. Methods and Materials: From 2009 to 2014, 24 patients with 32 recurrent keloids were treated with immediate perioperative high-dose-rate brachytherapy; 3 patients had been previously treated with adjuvant external beam radiation therapy and presented with recurrences in the pretreated areas. Two or more different treatment modalities had been tried in all patients and had failed to achieve remission. After (re-)excision of the keloids, a single brachytherapy tube was placed subcutaneously before closing the wound. The target volume covered the scar in total length. Brachytherapy was given in 3 fractions with a single dose of 6 Gy in 5 mm tissue depth. The first fraction was given within 6 hours after surgery, the other 2 fractions on the first postoperative day. Thus, a total dose of 18 Gy in 3 fractions was administered within 36 hours after the resection. Results: The treatment was feasible in all patients. No procedure-related complications (eg, secondary infections) occurred. Nineteen patients had keloid-related symptoms before treatment like pain and pruritus; disappearance of symptoms was noticed in all patients after treatment. After a median follow-up of 29.4 months (range, 7.9-72.4 months), 2 keloid recurrences and 2 mildly hypertrophied scars were observed. The local control rate was 94%. Pigmentary abnormalities were detected in 3 patients, and an additional 6 patients had a mild delay in the wound-healing process. Conclusions: The early results of this study prove the feasibility and the efficacy of brachytherapy for the prevention of keloids. The results also suggest that brachytherapy may be advantageous in the management of high-risk keloids or as salvage treatment for failure after external beam therapy.

  19. Dose escalation using conformal high-dose-rate brachytherapy improves outcome in unfavorable prostate cancer

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gustafson, Gary; Gonzalez, Jose; Armour, Elwood; Mitchell, Chris; Edmundson, Gregory; Spencer, William; Stromberg, Jannifer; Huang, Raywin; Vicini, Frank

    2002-01-01

    Purpose: To overcome radioresistance for patients with unfavorable prostate cancer, a prospective trial of pelvic external beam irradiation (EBRT) interdigitated with dose-escalating conformal high-dose-rate (HDR) prostate brachytherapy was performed. Methods and Materials: Between November 1991 and August 2000, 207 patients were treated with 46 Gy pelvic EBRT and increasing HDR brachytherapy boost doses (5.50-11.5 Gy/fraction) during 5 weeks. The eligibility criteria were pretreatment prostate-specific antigen level ≥10.0 ng/mL, Gleason score ≥7, or clinical Stage T2b or higher. Patients were divided into 2 dose levels, low-dose biologically effective dose 93 Gy (149 patients). No patient received hormones. We used the American Society for Therapeutic Radiology and Oncology definition for biochemical failure. Results: The median age was 69 years. The mean follow-up for the group was 4.4 years, and for the low and high-dose levels, it was 7.0 and 3.4 years, respectively. The actuarial 5-year biochemical control rate was 74%, and the overall, cause-specific, and disease-free survival rate was 92%, 98%, and 68%, respectively. The 5-year biochemical control rate for the low-dose group was 52%; the rate for the high-dose group was 87% (p<0.001). Improvement occurred in the cause-specific survival in favor of the brachytherapy high-dose level (p=0.014). On multivariate analysis, a low-dose level, higher Gleason score, and higher nadir value were associated with increased biochemical failure. The Radiation Therapy Oncology Group Grade 3 gastrointestinal/genitourinary complications ranged from 0.5% to 9%. The actuarial 5-year impotency rate was 51%. Conclusion: Pelvic EBRT interdigitated with transrectal ultrasound-guided real-time conformal HDR prostate brachytherapy boost is both a precise dose delivery system and a very effective treatment for unfavorable prostate cancer. We demonstrated an incremental beneficial effect on biochemical control and cause

  20. Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Larissa J. [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts (United States); Viswanathan, Akila N., E-mail: aviswanathan@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Harvard Medical School, Boston, Massachusetts (United States)

    2012-12-01

    Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adverse Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to ensure

  1. Predictors of Toxicity After Image-guided High-dose-rate Interstitial Brachytherapy for Gynecologic Cancer

    International Nuclear Information System (INIS)

    Lee, Larissa J.; Viswanathan, Akila N.

    2012-01-01

    Purpose: To identify predictors of grade 3-4 complications and grade 2-4 rectal toxicity after three-dimensional image-guided high-dose-rate (HDR) interstitial brachytherapy for gynecologic cancer. Methods and Materials: Records were reviewed for 51 women (22 with primary disease and 29 with recurrence) treated with HDR interstitial brachytherapy. A single interstitial insertion was performed with image guidance by computed tomography (n = 43) or magnetic resonance imaging (n = 8). The median delivered dose in equivalent 2-Gy fractions was 72.0 Gy (45 Gy for external-beam radiation therapy and 24 Gy for brachytherapy). Toxicity was reported according to the Common Toxicity Criteria for Adverse Events. Actuarial toxicity estimates were calculated by the Kaplan-Meier method. Results: At diagnosis, the median patient age was 62 years and the median tumor size was 3.8 cm. The median D90 and V100 were 71.4 Gy and 89.5%; the median D2cc for the bladder, rectum, and sigmoid were 64.6 Gy, 61.0 Gy, and 52.7 Gy, respectively. The actuarial rates of all grade 3-4 complications at 2 years were 20% gastrointestinal, 9% vaginal, 6% skin, 3% musculoskeletal, and 2% lymphatic. There were no grade 3-4 genitourinary complications and no grade 5 toxicities. Grade 2-4 rectal toxicity was observed in 10 patients, and grade 3-4 complications in 4; all cases were proctitis with the exception of 1 rectal fistula. D2cc for rectum was higher for patients with grade 2-4 (68 Gy vs 57 Gy for grade 0-1, P=.03) and grade 3-4 (73 Gy vs 58 Gy for grade 0-2, P=.02) rectal toxicity. The estimated dose that resulted in a 10% risk of grade 2-4 rectal toxicity was 61.8 Gy (95% confidence interval, 51.5-72.2 Gy). Discussion: Image-guided HDR interstitial brachytherapy results in acceptable toxicity for women with primary or recurrent gynecologic cancer. D2cc for the rectum is a reliable predictor of late rectal complications. Three-dimensional-based treatment planning should be performed to ensure

  2. Inverse Planned High-Dose-Rate Brachytherapy for Locoregionally Advanced Cervical Cancer: 4-Year Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Tinkle, Christopher L.; Weinberg, Vivian [Department of Radiation Oncology, University of California, San Francisco, California (United States); Chen, Lee-May [Department of Obstetrics, Gynecology, and Reproductive Sciences, University of California, San Francisco, California (United States); Littell, Ramey [Gynecologic Oncology, The Permanente Medical Group, San Francisco, California (United States); Cunha, J. Adam M.; Sethi, Rajni A. [Department of Radiation Oncology, University of California, San Francisco, California (United States); Chan, John K. [Gynecologic Oncology, California Pacific Medical Center, San Francisco, California (United States); Hsu, I-Chow, E-mail: ichow.hsu@ucsf.edu [Department of Radiation Oncology, University of California, San Francisco, California (United States)

    2015-08-01

    Purpose: Evaluate the efficacy and toxicity of image guided brachytherapy using inverse planning simulated annealing (IPSA) high-dose-rate brachytherapy (HDRB) boost for locoregionally advanced cervical cancer. Methods and Materials: From December 2003 through September 2009, 111 patients with primary cervical cancer were treated definitively with IPSA-planned HDRB boost (28 Gy in 4 fractions) after external radiation at our institution. We performed a retrospective review of our experience using image guided brachytherapy. Of the patients, 70% had a tumor size >4 cm, 38% had regional nodal disease, and 15% had clinically evident distant metastasis, including nonregional nodal disease, at the time of diagnosis. Surgical staging involving pelvic lymph node dissection was performed in 15% of patients, and 93% received concurrent cisplatin-based chemotherapy. Toxicities are reported according to the Common Terminology Criteria for Adverse Events version 4.0 guidelines. Results: With a median follow-up time of 42 months (range, 3-84 months), no acute or late toxicities of grade 4 or higher were observed, and grade 3 toxicities (both acute and late) developed in 8 patients (1 constitutional, 1 hematologic, 2 genitourinary, 4 gastrointestinal). The 4-year Kaplan-Meier estimate of late grade 3 toxicity was 8%. Local recurrence developed in 5 patients (4 to 9 months after HDRB), regional recurrence in 3 (6, 16, and 72 months after HDRB), and locoregional recurrence in 1 (4 months after HDR boost). The 4-year estimates of local, locoregional, and distant control of disease were 94.0%, 91.9%, and 69.1%, respectively. The overall and disease-free survival rates at 4 years were 64.3% (95% confidence interval [CI] of 54%-73%) and 61.0% (95% CI, 51%-70%), respectively. Conclusions: Definitive radiation by use of inverse planned HDRB boost for locoregionally advanced cervical cancer is well tolerated and achieves excellent local control of disease. However, overall

  3. Interstitial high-dose rate brachytherapy as boost for anal canal cancer

    International Nuclear Information System (INIS)

    Falk, Alexander Tuan; Claren, Audrey; Benezery, Karen; François, Eric; Gautier, Mathieu; Gerard, Jean-Pierre; Hannoun-Levi, Jean-Michel

    2014-01-01

    To assess clinical outcomes of patients treated with a high-dose rate brachytherapy boost for anal canal cancer (ACC). From August 2005 to February 2013, 28 patients presenting an ACC treated by split-course external beam radiotherapy (EBRT) and HDR brachytherapy with or without chemotherapy in a French regional cancer center in Nice were retrospectively analyzed. Median age was 60.6 years [34 – 83], 25 patients presented a squamous cell carcinoma and 3 an adenocarcinoma; 21 received chemotherapy. Median dose of EBRT was 45 Gy [43.2 – 52]. Median dose of HDR brachytherapy was 12 Gy [10 - 15] with a median duration of 2 days. Median overall treatment time was 63 days and median delay between EBRT and brachytherapy was 20 days. Two-year local relapse free, metastatic free, disease free and overall survivals were 83%, 81.9%, 71.8% and 87.7% respectively. Acute toxicities were frequent but not severe with mostly grade 1 toxicities: 37% of genito-urinary, 40.7% of gastro-intestinal and 3.7% of cutaneous toxicities. Late toxicities were mainly G1 (43.1%) and G2 (22%). Two-year colostomy-free survival was 75.1%, one patient had a definitive sphincter amputation. High-dose rate brachytherapy for anal canal carcinoma as boost represents a feasible technique compared to low or pulsed-dose rate brachytherapy. This technique remains an excellent approach to precisely boost the tumor in reducing the overall treatment time

  4. Applicability and dosimetric impact of ultrasound-based preplanning in high-dose-rate brachytherapy of prostate cancer

    International Nuclear Information System (INIS)

    Aebersold, D.M.; Isaak, B.; Behrensmeier, F.; Kolotas, C.; Mini, R.; Greiner, R.H.; Thalmann, G.; Kranzbuehler, H.

    2004-01-01

    Background and purpose: analyses of permanent brachytherapy seed implants of the prostate have demonstrated that the use of a preplan may lead to a considerable decrease of dosimetric implant quality. The authors aimed to determine whether the same drawbacks of preplanning also apply to high-dose-rate (HDR) brachytherapy. Patients and methods: 15 patients who underwent two separate HDR brachytherapy implants in addition to external-beam radiation therapy for advanced prostate cancer were analyzed. A pretherapeutic transrectal ultrasound was performed in all patients to generate a preplan for the first brachytherapy implant. For the second brachytherapy, a subset of patients were treated by preplans based on the ultrasound from the first brachytherapy implant. Preplans were compared with the respective postplans assessing the following parameters: coverage index, minimum target dose, homogeneity index, and dose exposure of organs at risk. The prostate geometries (volume, width, height, length) were compared as well. Results: at the first brachytherapy, the matching between the preplan and actual implant geometry was sufficient in 47% of the patients, and the preplan could be applied. The dosimetric implant quality decreased considerably: the mean coverage differed by -0.11, the mean minimum target dose by -0.15, the mean homogeneity index by -0.09. The exposure of organs at risk was not substantially altered. At the second brachytherapy, all patients could be treated by the preplan; the differences between the implant quality parameters were less pronounced. The changes of prostate geometry between preplans and postplans were considerable, the differences in volume ranging from -8.0 to 13.8 cm 3 and in dimensions (width, height, length) from -1.1 to 1.0 cm. Conclusion: preplanning in HDR brachytherapy of the prostate is associated with a substantial decrease of dosimetric implant quality, when the preplan is based on a pretherapeutic ultrasound. The implant quality

  5. Adherence to Vaginal Dilation Following High Dose Rate Brachytherapy for Endometrial Cancer

    International Nuclear Information System (INIS)

    Friedman, Lois C.; Abdallah, Rita; Schluchter, Mark; Panneerselvam, Ashok; Kunos, Charles A.

    2011-01-01

    Purpose: We report demographic, clinical, and psychosocial factors associated with adherence to vaginal dilation and describe the sexual and marital or nonmarital dyadic functioning of women following high dose rate (HDR) brachytherapy for endometrial cancer. Methods and Materials: We retrospectively evaluated women aged 18 years or older in whom early-stage endometrial (IAgr3-IIB) cancers were treated by HDR intravaginal brachytherapy within the past 3.5 years. Women with or without a sexual partner were eligible. Patients completed questionnaires by mail or by telephone assessing demographic and clinical variables, adherence to vaginal dilation, dyadic satisfaction, sexual functioning, and health beliefs. Results: Seventy-eight of 89 (88%) eligible women with early-stage endometrial cancer treated with HDR brachytherapy completed questionnaires. Only 33% of patients were adherers, based on reporting having used a dilator more than two times per week in the first month following radiation. Nonadherers who reported a perceived change in vaginal dimension following radiation reported that their vaginas were subjectively smaller after brachytherapy (p = 0.013). Adherers reported more worry about their sex lives or lack thereof than nonadherers (p = 0.047). Patients reported considerable sexual dysfunction following completion of HDR brachytherapy. Conclusions: Adherence to recommendations for vaginal dilator use following HDR brachytherapy for endometrial cancer is poor. Interventions designed to educate women about dilator use benefit may increase adherence. Although sexual functioning was compromised, it is likely that this existed before having cancer for many women in our study.

  6. High-Dose-Rate Monotherapy: Safe and Effective Brachytherapy for Patients With Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Demanes, D. Jeffrey; Martinez, Alvaro A.; Ghilezan, Michel; Hill, Dennis R.; Schour, Lionel; Brandt, David; Gustafson, Gary

    2011-01-01

    Purpose: High-dose-rate (HDR) brachytherapy used as the only treatment (monotherapy) for early prostate cancer is consistent with current concepts in prostate radiobiology, and the dose is reliably delivered in a prospectively defined anatomic distribution that meets all the requirements for safe and effective therapy. We report the disease control and toxicity of HDR monotherapy from California Endocurietherapy (CET) and William Beaumont Hospital (WBH) in low- and intermediate-risk prostate cancer patients. Methods and Materials: There were 298 patients with localized prostate cancer treated with HDR monotherapy between 1996 and 2005. Two biologically equivalent hypofractionation protocols were used. At CET the dose was 42 Gy in six fractions (two implantations 1 week apart) delivered to a computed tomography–defined planning treatment volume. At WBH the dose was 38 Gy in four fractions (one implantation) based on intraoperative transrectal ultrasound real-time treatment planning. The bladder, urethral, and rectal dose constraints were similar. Toxicity was scored with the National Cancer Institute Common Toxicity Criteria for Adverse Events version 3. Results: The median follow-up time was 5.2 years. The median age of the patients was 63 years, and the median value of the pretreatment prostate-specific antigen was 6.0 ng/mL. The 8-year results were 99% local control, 97% biochemical control (nadir +2), 99% distant metastasis–free survival, 99% cause-specific survival, and 95% overall survival. Toxicity was scored per event, meaning that an individual patient with more than one symptom was represented repeatedly in the morbidity data table. Genitourinary toxicity consisted of 10% transient Grade 2 urinary frequency or urgency and 3% Grade 3 episode of urinary retention. Gastrointestinal toxicity was <1%. Conclusions: High disease control rates and low morbidity demonstrate that HDR monotherapy is safe and effective for patients with localized prostate cancer.

  7. Evaluation of performance and quality control of high dose rate Ir-192 remote afterloading brachytherapy equipment

    International Nuclear Information System (INIS)

    Ahmed, M. A. M.

    2005-09-01

    Brachytherapy is the use of encapsulated radioactive sources to deliver a radiation dose at a short distance over a short time for treatment of malignant tumors. In Sudan, mainly in Radiation and Isotopes Center Khartoum (RICK) brachytherapy was introduced in 1989 using manual afterloading low dose rate 137 Cs for treatment of carcinoma of the cervix, but for safety reasons now it replace by high dose rate 192 Ir afterloading system (HDR) with remotely controlled device to deliver controlled radiation dose for treatment of carcinoma of cervix, esophagus and nasopharynx. This study was carried out in high dose rate 192 Ir afterloading brachytherapy equipment (Gamma Med 12i unit) located at RICK to evaluate the performance and to perform comprehensive quality control of the treatment unit with respect to three poles: safety systems, physical parameters and calibration of Ir-192 source through some quality control checks, so as to ensure that the equipment meets the safety standard. The study shows that all the safety systems which include the mechanical checks are work properly, the average of the dose rate measured at different positions from the treatment unit which represent the leakage radiation by using RDS-120 universal survey meter is less than 10μSv/h. The physical parameters which include the check of a source position accuracy by using x-OMAT ready pack film and catheter guide tube is I mm. The source strength that was obtained from the calibration procedures following the IAEA-TECDOC 1274 protocol by using HDR 1000 plus well type ionization chamber is different from the value of International Standard Laboratory by 1.5%. It was found that the brachytherapy equipment and the source used in brachytherapy meets the users requirements except some necessary requirements, so some recommendations was putted include these requirements.(Author)

  8. MRI dosimetry using an echo-quotient technique for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Ansbacher, W.

    1996-01-01

    MRI gel dosimetry is a relatively new technique that has many advantages over conventional methods, and is particularly suited to High Dose Rate (HDR) Brachytherapy. The dosimeter has high spatial resolution and a water-equivalent response over a wide range of photon energies. Because it is an integrating dosimeter, it allows for efficient mapping of the dynamically-produced distributions from an HDR source. As an example of this technique, the dose response, which is calibrated in terms of the change in spin-spin relaxation time, has been used to investigate the anisotropy of an HDR source. (author). 1 fig

  9. High-dose-rate brachytherapy as salvage modality for locally recurrent prostate cancer after definitive radiotherapy. A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Chatzikonstantinou, Georgios; Zamboglou, Nikolaos; Roedel, Claus; Tselis, Nikolaos [J.W. Goethe University of Frankfurt, Department of Radiotherapy and Oncology, Frankfurt am Main (Germany); Zoga, Eleni [Sana Klinikum Offenbach, Department of Radiotherapy and Oncology, Offenbach am Main (Germany); Strouthos, Iosif [Medical Center - University of Freiburg, Department of Radiotherapy and Oncology, University of Freiburg, Freiburg (Germany); Butt, Saeed Ahmed [Sana Klinikum Offenbach, Department of Medical Physics and Engineering, Offenbach am Main (Germany)

    2017-09-15

    To review the current status of interstitial high-dose-rate brachytherapy as a salvage modality (sHDR BRT) for locally recurrent prostate cancer after definitive radiotherapy (RT). A literature search was performed in PubMed using ''high-dose-rate, brachytherapy, prostate cancer, salvage'' as search terms. In all, 51 search results published between 2000 and 2016 were identified. Data tables were generated and summary descriptions created. The main outcome parameters used were biochemical control (BC) and toxicity scores. Eleven publications reported clinical outcome and toxicity with follow-up ranging from 4-191 months. A variety of dose and fractionation schedules were described, including 19.0 Gy in 2 fractions up to 42.0 Gy in 6 fractions. The 5-year BC ranged from 18-77%. Late grade 3 genitourinary and gastrointestinal toxicity was 0-32% and 0-5.1%, respectively. sHDR BRT appears as safe and effective salvage modality for the reirradiation of locally recurrent prostate cancer after definitive RT. (orig.) [German] Zusammenfassende Darstellung relevanter Literatur zur interstitiellen High-Dose-Rate-Brachytherapie als Salvage-Modalitaet (sHDR-BRT) bei der Behandlung des lokal rezidivierten Prostatakarzinoms nach vorausgegangener definitiver Radiotherapie (RT). In der PubMed-Datenbank wurde eine Literaturrecherche mit den Suchbegriffen ''high-dose-rate, brachytherapy, prostate cancer, salvage'' durchgefuehrt. Zwischen den Jahren 2000 und 2016 wurden 51 Publikationen identifiziert. Die biochemische Kontrolle (BC) sowie das assoziierte Toxizitaetsprofil waren onkologische Hauptpunkte in der Analyse der beruecksichtigten Literatur. Von onkologischen Ergebnissen und Toxizitaeten berichteten 11 Publikationen bei einer medianen Nachbeobachtungszeit von 4-191 Monaten. Eine Variabilitaet von Dosis- und Fraktionierungsregimen wurde beschrieben mit totalen physikalischen Dosen von 19,0 Gy in 2 Fraktionen bis zu 42,0 Gy in 6 Fraktionen

  10. Second salvage high-dose-rate brachytherapy for radiorecurrent prostate cancer

    Directory of Open Access Journals (Sweden)

    Metha Maenhout

    2017-04-01

    Full Text Available Purpose : Salvage treatments for localized radiorecurrent prostate cancer can be performed safely when a focal and image guided approach is used. Due to the low toxicity, the opportunity exists to investigate a second salvage treatment when a second locally recurrent prostate cancer occurs. Here, we describe a second salvage treatment procedure of 4 patients. Material and methods : Four patients with a pathologically proven second local recurrence were treated in an outpatient magnetic resonance imaging (MRI-guided setting with a single fraction of 19 Gy focal high-dose-rate brachytherapy (HDR-BT. Delineation was performed using choline-PET-CT or a 68Ga-PSMA PET in combination with multiparametric 3 Tesla MRI in all four patients. Toxicity was measured using common toxicity criteria for adverse events (CTCAE version 4.0. Results : With a median follow-up of 12 months (range, 6-15, there were 2 patients with biochemical recurrence as defined by the Phoenix-definition. There were no patients with grade 3 or more toxicity. In all second salvage HDR-BT treatments, the constraints for rectum, bladder, and urethra were met. Median treatment volume (GTV was 4.8 cc (range, 1.9-6.6 cc. A median of 8 catheters (range, 6-9 were used, and the median dose to the treatment volume (GTV was a D95: 19.3 Gy (SD 15.5-19.4 Gy. Conclusions : Second focal salvage MRI-guided HDR-BT for a select group of patients with a second locally recurrent prostate cancer is feasible. There was no grade 3 or more acute toxicity for these four patients.

  11. Long-term results of curative intraluminal high dose rate brachytherapy for endobronchial carcinoma

    Directory of Open Access Journals (Sweden)

    Kawamura Hidemasa

    2012-07-01

    Full Text Available Abstract Background The treatment strategy of central lung tumors is not established. Intraluminal brachytherapy (ILBT is widely used for palliative treatment of endobronchial tumors, however, it is also a promising option for curative treatment with limited data. This study evaluates the results after ILBT for endobronchial carcinoma. Method Sixteen-endobronchial carcinoma of 13 patients treated with ILBT in curative intent for 2000 to 2008 were retrospectively reviewed. ILBT using high dose rate 192 iridium thin wire system was performed with 5 Gy/fraction at mucosal surface. The patient age ranged from 57 to 82 years old with median 75 years old. The 16 lesions consisted of 13 central endobronchial cancers including 7 roentgenographically occult lung cancers and 3 of tracheal cancers. Of them, 10 lesions were treated with ILBT of median 20 Gy combined with external beam radiation therapy of median 45 Gy and 6 lesions were treated with ILBT alone of median 25 Gy. Results Median follow-up time was 32.5 months. Two-year survival rate and local control rate were 92.3% and 86.2%, respectively. Local recurrences were observed in 2 lesions. Three patients died due to lung cancer (1 patient and intercurrent disease (2 patients. Complications greater than grade 2 were not observed except for one grade 3 dyspnea. Conclusions ILBT combined with or without EBRT might be a curative treatment option in inoperable endobronchial carcinoma patients with tolerable complication.

  12. Monte Carlo dose calculations for high-dose-rate brachytherapy using GPU-accelerated processing.

    Science.gov (United States)

    Tian, Z; Zhang, M; Hrycushko, B; Albuquerque, K; Jiang, S B; Jia, X

    2016-01-01

    Current clinical brachytherapy dose calculations are typically based on the Association of American Physicists in Medicine Task Group report 43 (TG-43) guidelines, which approximate patient geometry as an infinitely large water phantom. This ignores patient and applicator geometries and heterogeneities, causing dosimetric errors. Although Monte Carlo (MC) dose calculation is commonly recognized as the most accurate method, its associated long computational time is a major bottleneck for routine clinical applications. This article presents our recent developments of a fast MC dose calculation package for high-dose-rate (HDR) brachytherapy, gBMC, built on a graphics processing unit (GPU) platform. gBMC-simulated photon transport in voxelized geometry with physics in (192)Ir HDR brachytherapy energy range considered. A phase-space file was used as a source model. GPU-based parallel computation was used to simultaneously transport multiple photons, one on a GPU thread. We validated gBMC by comparing the dose calculation results in water with that computed TG-43. We also studied heterogeneous phantom cases and a patient case and compared gBMC results with Acuros BV results. Radial dose function in water calculated by gBMC showed GPU-based MC dose calculation package, gBMC, for HDR brachytherapy make it attractive for clinical applications. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. Nationwide, Multicenter, Retrospective Study on High-Dose-Rate Brachytherapy as Monotherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Yasuo, E-mail: yoshioka@radonc.med.osaka-u.ac.jp [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Kotsuma, Tadayuki [Department of Radiation Oncology, Osaka National Hospital, Osaka (Japan); Komiya, Akira [Department of Urology, Graduate School of Medicine and Pharmaceutical Sciences for Research, University of Toyama, Toyama (Japan); Department of Urology, Chiba University Hospital, Chiba (Japan); Kariya, Shinji [Department of Radiology, Kochi Medical School, Kochi (Japan); Konishi, Koji [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Nonomura, Norio [Department of Urology, Osaka University Graduate School of Medicine, Osaka (Japan); Ogawa, Kazuhiko [Department of Radiation Oncology, Osaka University Graduate School of Medicine, Osaka (Japan); Tanaka, Eiichi [Department of Radiation Oncology, Osaka National Hospital, Osaka (Japan); Nishimura, Kensaku [Department of Urology, Osaka National Hospital, Osaka (Japan); Fujiuchi, Yasuyoshi; Kitamura, Hiroshi [Department of Urology, Graduate School of Medicine and Pharmaceutical Sciences for Research, University of Toyama, Toyama (Japan); Yamagami, Takuji [Department of Radiology, Kochi Medical School, Kochi (Japan); Yamasaki, Ichiro [Department of Urology, Kochi Medical School, Kochi (Japan); Nishimura, Kazuo [Department of Urology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Teshima, Teruki [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Nakamura, Katsumasa [Department of Radiation Oncology, Hamamatsu University School of Medicine, Shizuoka (Japan); Itami, Jun [Department of Radiation Oncology, National Cancer Center Hospital, Tokyo (Japan)

    2017-04-01

    Purpose: To present, analyze, and discuss results of a nationwide, multicenter, retrospective study on high-dose-rate brachytherapy (HDR-BT) as monotherapy for low-, intermediate-, and high-risk prostate cancer. Methods and Materials: From 1995 through 2013, 524 patients, 73 (14%) with low-risk, 207 (40%) with intermediate-risk, and 244 (47%) with high-risk prostate cancer, were treated with HDR-BT as monotherapy at 5 institutions in Japan. Dose fractionations were 27 Gy/2 fractions for 69 patients (13%), 45.5 Gy/7 fractions for 168 (32%), 49 Gy/7 fractions for 149 (28%), 54 Gy/9 fractions for 130 (25%), and others for 8 (2%). Of these patients, 156 (30%) did not receive androgen deprivation therapy, and 202 patients (39%) did receive androgen deprivation therapy <1 year, 112 (21%) for 1-3 years, and 54 (10%) for >3 years. Median follow-up time was 5.9 years (range, 0.4-18.1 years), with a minimum of 2 years for surviving patients. Results: After 5 years, respective actuarial rates of no biochemical evidence of disease, overall survival, cause-specific survival, and metastasis-free survival for all patients were 92%, 97%, 99%, and 94%. For low/intermediate/high-risk patients, the 5-year no biochemical evidence of disease rates were 95%/94%/89%, the 5-year overall survival rates were 98%/98%/94%, the 5-year cause-specific survival rates were 98%/100%/98%, and the 5-year metastasis-free survival rates were 98%/95%/90%, respectively. The cumulative incidence of late grade 2 to 3 genitourinary toxicity at 5 years was 19%, and that of late grade 3 was 1%. The corresponding incidences of gastrointestinal toxicity were 3% and 0% (0.2%). No grade 4 or 5 of either type of toxicity was detected. Conclusions: The findings of this nationwide, multicenter, retrospective study demonstrate that HDR-BT as monotherapy was safe and effective for all patients with low-, intermediate-, and high-risk prostate cancer.

  14. Determination of the tissue inhomogeneity correction in high dose rate Brachytherapy for Iridium-192 source

    Directory of Open Access Journals (Sweden)

    Barlanka Ravikumar

    2012-01-01

    Full Text Available In Brachytherapy treatment planning, the effects of tissue heterogeneities are commonly neglected due to lack of accurate, general and fast three-dimensional (3D dose-computational algorithms. In performing dose calculations, it is assumed that the tumor and surrounding tissues constitute a uniform, homogeneous medium equivalent to water. In the recent past, three-dimensional computed tomography (3D-CT based treatment planning for Brachytherapy applications has been popularly adopted. However, most of the current commercially available planning systems do not provide the heterogeneity corrections for Brachytherapy dosimetry. In the present study, we have measured and quantified the impact of inhomogeneity caused by different tissues with a 0.015 cc ion chamber. Measurements were carried out in wax phantom which was employed to measure the heterogeneity. Iridium-192 (192 Ir source from high dose rate (HDR Brachytherapy machine was used as the radiation source. The reduction of dose due to tissue inhomogeneity was measured as the ratio of dose measured with different types of inhomogeneity (bone, spleen, liver, muscle and lung to dose measured with homogeneous medium for different distances. It was observed that different tissues attenuate differently, with bone tissue showing maximum attenuation value and lung tissue resulting minimum value and rest of the tissues giving values lying in between those of bone and lung. It was also found that inhomogeneity at short distance is considerably more than that at larger distances.

  15. Biological effective doses in the intracavitary high dose rate brachytherapy of cervical cancer

    Directory of Open Access Journals (Sweden)

    Y. Sobita Devi

    2011-12-01

    Full Text Available Purpose: The aim of this study is to evaluate the decrease of biological equivalent dose and its correlation withlocal/loco-regional control of tumour in the treatment of cervical cancer when the strength of the Ir-192 high dose rate(HDR brachytherapy (BT source is reduced to single, double and triple half life in relation to original strength of10 Ci (~ 4.081 cGy x m2 x h–1. Material and methods: A retrospective study was carried out on 52 cervical cancer patients with stage II and IIItreated with fractionated HDR-BT following external beam radiation therapy (EBRT. International Commission onRadiation Units and Measurement (ICRU points were defined according to ICRU Report 38, using two orthogonal radiographimages taken by Simulator (Simulix HQ. Biologically effective dose (BED was calculated at point A for diffe -rent Ir-192 source strength and its possible correlation with local/loco-regional tumour control was discussed. Result: The increase of treatment time per fraction of dose due to the fall of dose rate especially in HDR-BT of cervicalcancer results in reduction in BED of 2.59%, 7.02% and 13.68% with single, double and triple half life reduction ofsource strength, respectively. The probabilities of disease recurrence (local/loco-regional within 26 months are expectedas 0.12, 0.12, 0.16, 0.39 and 0.80 for source strength of 4.081, 2.041, 1.020, 0.510 and 0.347 cGy x m2 x h–1, respectively.The percentages of dose increase required to maintain the same BED with respect to initial BED were estimated as1.71, 5.00, 11.00 and 15.86 for the dose rate of 24.7, 12.4, 6.2 and 4.2 Gy/hr at point A, respectively. Conclusions: This retrospective study of cervical cancer patients treated with HDR-BT at different Ir-192 sourcestrength shows reduction in disease free survival according to the increase in treatment time duration per fraction.The probable result could be associated with the decrease of biological equivalent dose to point A. Clinical

  16. Assessing patient characteristics and radiation-induced non-targeted effects in vivo for high dose-rate (HDR) brachytherapy.

    Science.gov (United States)

    Pinho, Christine; Timotin, Emilia; Wong, Raimond; Sur, Ranjan K; Hayward, Joseph E; Farrell, Thomas J; Seymour, Colin; Mothersill, Carmel

    2015-01-01

    To test whether blood, urine, and tissue based colony-forming assays are a useful clinical detection tool for assessing fractionated treatment responses and non-targeted radiation effects in bystander cells. To assess patients' responses to radiation treatments, blood serum, urine, and an esophagus explant-based in vivo colony-forming assay were used from oesophageal carcinoma patients. These patients underwent three fractions of high dose rate (HDR) intraluminal brachytherapy (ILBT). Human keratinocyte reporters exposed to blood sera taken after the third fraction of brachytherapy had a significant increase in cloning efficiency compared to baseline samples (p fractions for the blood sera data only. Patient characteristics such as gender had no statistically significant effect (p > 0.05). Large variability was observed among the patients' tissue samples, these colony-forming assays showed no significant changes throughout fractionated brachytherapy (p > 0.05). Large inter-patient variability was found in the urine and tissue based assays, so these techniques were discontinued. However, the simple blood-based assay had much less variability. This technique may have future applications as a biological dosimeter to predict treatment outcome and assess non-targeted radiation effects.

  17. Non-melanoma skin cancer treated with high-dose-rate brachytherapy: a review of literature

    Directory of Open Access Journals (Sweden)

    Durim Delishaj

    2016-12-01

    Full Text Available Purpose: The incidence of non-melanoma skin cancer (NMSC has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT might be a better therapeutic option due to high radiation dose concentration to the tumor with rapid dose fall-off resulting in normal tissues sparing. The aim of this review was to evaluate the local control, toxicity, and cosmetic outcomes in NMSC treated with high-dose-rate BT (HDR-BT. Material and methods: In May 2016, a systematic search of bibliographic database of PubMed, Web of Science, Scopus, and Cochrane Library with a combination of key words of “skin cancer”, “high dose rate brachytherapy”, “squamous cell carcinoma”, “basal cell carcinoma”, and “non melanoma skin cancer“ was performed. In this systematic review, we included randomized trials, non-randomized trials, prospective and retrospective studies in patients affected by NMSC treated with HDR-BT. Results: Our searches generated a total of 85 results, and through a process of screening, 10 publications were selected for the review. Brachytherapy was well tolerated with acceptable toxicity and high local control rates (median: 97%. Cosmetic outcome was reported in seven study and consisted in an excellent and good cosmetic results in 94.8% of cases. Conclusions : Based on the review data, we can conclude that the treatment of NMSC with HDR-BT is effective with excellent and good cosmetics results, even in elderly patients. The hypofractionated course appears effective with very good local disease control. More data with large-scale randomized controlled trials are needed to assess the efficacy and safety of brachytherapy.

  18. Local vaginal anesthesia during high-dose-rate intracavitary brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Chen, H.-C.; Wan Leung, Stephen; Wang, C.-J.; Sun, L.-M.; Fang, F.-M.; Huang, E.-Y.; Wang, S.-J.; Yang, C.-W.

    1998-01-01

    Purpose: To evaluate the clinical efficacy of local vaginal lidocaine application for pain relief during high-dose-rate (HDR) intracavitary brachytherapy for patients with cervical cancer, and to investigate sequential changes in serum levels of lidocaine during the procedures. Methods and Materials: This prospective study was designed to examine the analgesic effect, physical response, and side effects of local anesthesia during HDR intracavitary brachytherapy. Forty patients were enrolled. All patients received 10-15 MV X-rays to the pelvis with a total dose of 45-59.4 Gy 5-6 weeks before undergoing HDR intracavitary brachytherapy. All patients underwent first intracavitary brachytherapy under general anesthesia. These patients were randomly allocated to receive one of two different treatment protocols as follows: (1) treatment session - control session - treatment session - control session; or (2) control session - treatment session- control session - treatment session. In the treatment sessions, topical anesthesia was administered using 4 ml of 10% lidocaine solution sprayed liberally on the cervix and vagina during intracavitary brachytherapy. In the control sessions, a placebo was administered in the same manner during brachytherapy. The Hensche's applicators for brachytherapy were inserted into the cervix and vagina 5 min after lidocaine application. The visual analogue scale (VAS) was used to assess pain and discomfort during brachytherapy. Blood pressure and heart rates were measured to evaluate the physiological response. Another prospective study was then performed to investigate the sequential changes of serum lidocaine levels during the anesthetic procedure. Eleven additional patients with similar disease state and demographic characteristics were enrolled and blood samples were obtained before, and 5, 15, 30, and 45 min after the initiation of lidocaine application. Results: The mean VAS values recorded during the treatment sessions and control

  19. Post-operative high dose rate vaginal apex brachytherapy in stage I endometrial adenocarcinoma

    International Nuclear Information System (INIS)

    Gumbs, A.A.; Turner, B.C.; Knisely, J.P.S.; Kacinski, B.M.; Roberts, K.B.; Peschel, R.E.; Haffty, B.G.; Rutherford, T.J.; Edraki, B.; Schwartz, P.E.; Wilson, L.D.

    1996-01-01

    Purpose/Objective: Patients with Stage I endometrial adenocarcinoma have traditionally been treated with total abdominal hysterectomy/bilateral salpingo-oophorectomy and radiation. The reported incidence of local recurrence in surgically treated patients with FIGO Stage IA or IB endometrial adenocarcinoma is 4-10% at 2 years. Combined surgery and radiation has resulted in a reduction of recurrence to 2-6%. We report the presentation, actuarial survival, actuarial rate of local failure, salvage rate, and complications for patients undergoing high dose rate (HDR) vaginal apex brachytherapy following surgery. Materials and Methods: Between 1985 and 1994 a total of 286 patients with FIGO Stage I endometrioid uterine adenocarcinoma were treated with HDR Ir-192 vaginal apex brachytherapy alone to a total dose of 21 Gy in 3 fractions at 0.5 cm from the vaginal mucosa. The pathologic stage by treatment group was IA: 31%, IB: 68%, and IC: 1%. The histologic grade of the patient's tumors was grade 1: 69%, 2: 29%, and 3: 2% of patients. The median time from surgery to radiation was 34 days (range 14-66 days). The median follow-up for 286 patients with Stage IA (92 patients), IB (190 patients), and IC (4 patients) was respectively, 37, 35 and 40 months (2 patients lost to follow-up prior to 6 months). Results: Patients presented with vaginal bleeding (94%) or abnormal pap smear (6%) at a median age for Stage IA and IB, of 54 and 63 years, respectively (range 32-88). The 5-year overall actuarial survival rate was 94.5%. The 5-year actuarial survival rate by histologic grade was 97.5% and 91.5% for FIGO grade 1 and 2, respectively (p=.011). The 5-year actuarial survival rate by depth of myometrial invasion was 99.0% and 92.5% for Stage IA and IB, respectively (p=.029). Median overall time to failure is 19.5 months (range 10-36 months). The 5-year actuarial rate of local failure was 4.5%. The overall failure rate in our study group was 2.8% (8 patients), local failure only 1

  20. [Prostate cancer boost using high-dose-rate brachytherapy: impact of the learning curve on the dosimetry].

    Science.gov (United States)

    Benhaïm, C; Chand, M-È; Gal, J; Hijazi, H; Gautier, M; Hannoun-Lévi, J-M

    2014-11-01

    To analyse the influence of the learning curve on dosimetric data for high-dose-rate brachytherapy prostate cancer boost. From February 2009 to May 2012, after a first course of external beam radiation therapy (46Gy/23 fractions), 124 patients underwent high-dose-rate brachytherapy boost using Plato™ (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden). The impact of the learning curve on the dosimetric quality of the prostate implant was assessed. The dosimetric data have been analysed: clinical target volume (CTV), D90 (dose to 90 % of CTV), D100, V100 (part on the CTV receiving 100 % of the dose), V150, V200 and DHI (dose non-homogeneity index). The doses delivered to 0.1, 1 and 2 cm(3) of the rectum and urethra were calculated. During the study period (39 months), a significant reduction of V150 (Plearning curve period. Copyright © 2014 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  1. Perioperative Interstitial High-Dose-Rate Brachytherapy for the Treatment of Recurrent Keloids

    DEFF Research Database (Denmark)

    Jiang, Ping; Baumann, René; Dunst, Jürgen

    2016-01-01

    was 94%. Pigmentary abnormalities were detected in 3 patients, and an additional 6 patients had a mild delay in the wound-healing process. CONCLUSIONS: The early results of this study prove the feasibility and the efficacy of brachytherapy for the prevention of keloids. The results also suggest....... After (re-)excision of the keloids, a single brachytherapy tube was placed subcutaneously before closing the wound. The target volume covered the scar in total length. Brachytherapy was given in 3 fractions with a single dose of 6 Gy in 5 mm tissue depth. The first fraction was given within 6 hours...

  2. Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Sarabiasl, Akbar; Ayoobian, Navid; Jabbari, Iraj; Poorbaygi, Hossein; Javanshir, Mohammad Reza

    2016-01-01

    High-dose-rate (HDR) brachytherapy is a common method for cancer treatment in clinical brachytherapy. Because of the different source designs, there is a need for specific dosimetry data set for each HDR model. The purpose of this study is to obtain detailed dose rate distributions in water phantom for a first prototype HDR 192 Ir brachytherapy source model, IRAsource, and compare with the other published works. In this study, Monte Carlo N-particle (MCNP version 4C) code was used to simulate the dose rate distributions around the HDR source. A full set of dosimetry parameters reported by the American Association of Physicists in Medicine Task Group No. 43U1 was evaluated. Also, the absorbed dose rate distributions in water, were obtained in an along-away look-up table. The dose rate constant, Λ, of the IRAsource was evaluated to be equal to 1.112 ± 0.005 cGy h −1 U −1 . The results of dosimetry parameters are presented in tabulated and graphical formats and compared with those reported from other commercially available HDR 192 Ir sources, which are in good agreement. This justifies the use of specific data sets for this new source. The results obtained in this study can be used as input data in the conventional treatment planning systems.

  3. Four year clinical statistics of iridium-192 high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Shigehara, Kazuyoshi; Mizokami, Atsushi; Komatsu, Kazuto; Koshida, Kiyoshi; Namiki, Mikio

    2006-01-01

    We evaluated the efficacy and complications of high dose rate (HDR) brachytherapy using iridium-192 ( 192 Ir) combined with external beam radiotherapy (EBRT) in patients with prostate cancer. Ninety-seven patients underwent 192 Ir HDR brachytherapy combined with EBRT at our institution between February 1999 and December 2003. Of these, 84 patients were analysed in the present study. 192 Ir was delivered three times over a period of 2 days, 6 Gy per time, for a total dose of 18 Gy. Interstitial application was followed by EBRT at a dose of 44 Gy. Progression was defined as three consecutive prostate-specific antigen (PSA) rises after a nadir according to the American Society for Therapeutic Radiology and Oncology criteria. The results were classified into those for all patients and for patients who did not undergo adjuvant hormone therapy. The 4-year overall survival of all patients, the nonadjuvant hormone therapy group (NAHT) and the adjuvant hormone therapy group (AHT) was 87.2%, 100%, and 70.1%, respectively. The PSA progression-free survival rate of all patients, NAHT, and AHT was 82.6%, 92.0%, and 66.6%, respectively. Of all patients, the 4-year PSA progression-free survival rates of PSA 192 Ir HDR brachytherapy combined with EBRT was as effective as radical prostatectomy and had few associated complications. (author)

  4. Independent technique of verifying high-dose rate (HDR) brachytherapy treatment plans

    International Nuclear Information System (INIS)

    Saw, Cheng B.; Korb, Leroy J.; Darnell, Brenda; Krishna, K. V.; Ulewicz, Dennis

    1998-01-01

    Purpose: An independent technique for verifying high-dose rate (HDR) brachytherapy treatment plans has been formulated and validated clinically. Methods and Materials: In HDR brachytherapy, dwell times at respective dwell positions are computed, using an optimization algorithm in a HDR treatment-planning system to deliver a specified dose to many target points simultaneously. Because of the variability of dwell times, concerns have been expressed regarding the ability of the algorithm to compute the correct dose. To address this concern, a commercially available low-dose rate (LDR) algorithm was used to compute the doses at defined distances, based on the dwell times obtained from the HDR treatment plans. The percent deviation between doses computed using the HDR and LDR algorithms were reviewed for HDR procedures performed over the last year. Results: In this retrospective study, the difference between computed doses using the HDR and LDR algorithms was found to be within 5% for about 80% of the HDR procedures. All of the reviewed procedures have dose differences of less than 10%. Conclusion: An independent technique for verifying HDR brachytherapy treatment plans has been validated based on clinical data. Provided both systems are available, this technique is universal in its applications and not limited to either a particular implant applicator, implant site, or implant type

  5. Concomitant cervical and transperineal parametrial high-dose-rate brachytherapy boost for locally advanced cervical cancer

    Directory of Open Access Journals (Sweden)

    Caroline Bailleux

    2016-01-01

    Full Text Available Purpose: There is no consensus for parametrial boost technic while both transvaginal and transperineal approaches are discussed. A prototype was developed consisting of a perineal template, allowing transperineal needle insertion. This study analyzed acute toxicity of concomitant cervical and transperineal parametrial high-dose-rate brachytherapy (HDRB boost for locally advanced cervical cancer. Material and methods: From 01.2011 to 12.2014, 33 patients (pts presenting a locally advanced cervical cancer with parametrial invasion were treated. After the first course of external beam radiation therapy with cisplatinum, HDRB was performed combining endocavitary and interstitial technique for cervical and parametrial disease. Post-operative delineation (CTV, bladder, rectum, sigmoid and planification were based on CT-scan/MRI. HDRB was delivered in 3-5 fractions over 2-3 consecutive days. Acute toxicities occurring within 6 months after HDRB were retrospectively reviewed. Results: Median age was 56.4 years (27-79. Clinical stages were: T2b = 23 pts (69.7%, T3a = 1 pt (3%, T3b = 6 pts (18.2%, and T4a = 3 pts (9.1%. Median HDRB prescribed dose was 21 Gy (21-27. Median CTVCT (16 pts and HR-CTV MRI (17 pts were 52.6 cc (28.5-74.3, 31.9 cc (17.1-58, respectively. Median EQD2αβ10 for D90CTV and D90HR-CTV were 82.9 Gy (78.2-96.5, 84.8 Gy (80.6-91.4, respectively. Median EQD2αβ3 (CT/MRI for D2cc bladder, rectum and sigmoid were 75.5 Gy (66.6-90.9, 64.4 Gy (51.9-77.4, and 60.4 Gy (50.9-81.1, respectively. Median follow-up was 14 months (ranged 6-51. Among the 24 pts with MFU = 24 months, 2-year LRFS rate, RRFS, and OS were 86.8%, 88.8%, and 94.1%, respectively. The rates of acute genitourinary and gastrointestinal toxicities were 36% (G1 dysuria = 8 pts, G2 infection = 2 pt, G3 infection = 2 pts, and 27% (G1 diarrhea = 9 pts, respectively. One patient presented vaginal bleeding at the time of applicator withdrawal (G3-blood transfusion; no bleeding was

  6. Experiences of high dose rate interstitial brachytherapy for carcinoma of the mobile tongue

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Hiroshi; Inoue, Toshihiko; Yamazaki, Hideya (Osaka Univ. (Japan). Faculty of Medicine) (and others)

    1994-03-01

    Interstitial brachytherapy was conducted for mobile tongue carcinoma using a high dose rate remote afterloading machine with small [sup 192]I source. Detailed method, named as 'linked double-botton technique', is to approach from submandibular skin by an open-ended stainless steel needles to the tongue lesion, and to replace each needle into flexible nylon tube from the oral cavity. Delivered dose was 60 Gy/10 Fr./5-6 days at the distance 5 mm from the source plane. Ten patients with mobile tongue carcinoma Tl-2N0 were treated with this method from October 1991 through August 1992. Local was uncontrolled in one patient, in whom the lesion was combined with leukoplakia at both lateral borders of the tongue. This was in accordance with the result in low dose rate treatment. This can be a substitute to low dose rate system for treatment of mobile tongue carcinoma. (author).

  7. Implementation of microsource high dose rate (mHDR) brachytherapy in developing countries

    International Nuclear Information System (INIS)

    2001-11-01

    Brachytherapy using remote afterloading of a single high dose rate 192 Ir microsource was developed in the 1970s. After its introduction to clinics, this system has spread rapidly among developed Member States and has become a highly desirable modality in cancer treatment. This technique is now gradually being introduced to the developing Member States. The 192 Ir sources are produced with a high specific activity. This results in a high dose rate (HDR) to the tumour and shorter treatment times. The high specific activity simultaneously results in a much smaller source (so-called micro source, around I mm in diameter) which may be easily inserted into tissue through a thin delivery tube, the so-called interstitial treatment, as well as easily inserted into body cavities, the so-called intracavitary or endoluminal treatment. Another advantage is the ability to change dwell time (the time a source remains in one position) of the stepping source which allows dose distribution to match the target volume more closely. The purpose of this TECDOC is to advise radiation oncologists, medical physicists and hospital administrators in hospitals which are planning to introduce 192 Ir microsource HDR (mHDR) remote afterloading systems. The document supplements IAEA-TECDOC-1040, Design and Implementation of a Radiotherapy Programme: Clinical, Medical Physics, Radiation Protection and Safety Aspects, and will facilitate implementation of this new brachytherapy technology, especially in developing countries. The operation of the system, 'how to use the system', is not within the scope of this document. This TECDOC is based on the recommendations of an Advisory Group meeting held in Vienna in April 1999

  8. Reference air kerma rate calibration system for high dose rate Ir-192 brachytherapy sources in Taiwan

    Science.gov (United States)

    Chu, Wei-Han; Yuan, Ming-Chen; Lee, Jeng-Hung; Lin, Yi-Chun

    2017-11-01

    Ir-192 sources are widely used in brachytherapy and the number of treatments is around seven thousand for the use of the high dose rate (HDR) Ir-192 brachytherapy source per year in Taiwan. Due to its physical half-life of 73.8 days, the source should be replaced four times per year to maintain the HDR treatment mode (DDEP, 2005; Coursey et al., 1992). When doing this work, it must perform the source dose trace to assure the dose accuracy. To establish the primary measurement standard of reference air kerma rate(RAKR) for the HDR Ir-192 brachytherapy sources in Taiwan, the Institute of Nuclear Energy Research (INER) fabricated a dual spherical graphite-walled cavity ionization chambers system to directly measure the RAKR of the Ir-192 brachytherapy source. In this system, the ion-charge was accumulated by the two ionization chambers and after correction for the ion recombination, temperature, atmosphere pressure, room scattering, graphite-wall attenuation, air attenuation, source decay, stem effect, and so on. The RAKR of the Ir-192 source was obtained in the ambient conditions of 22 °C and one atmosphere. The measurement uncertainty of the system was around 0.92% in 96% confidence level (k=2.0). To verify the accuracy of the result, the source calibration comparison has been made at the National Radiation Standard Laboratory (NRSL) of INER and Physikalisch-Technische Bundesanstalt (PTB, Germany) in 2015. The ratio of the measurement results between INER and PTB, INER/PTB, was 0.998±0.027 (k=2) which showed good consistency and the performance of the system was verified.

  9. Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Candela-Juan, Cristian; Granero, Domingo; Vijande, Javier; Ballester, Facundo; Perez-Calatayud, Jose; Rivard, Mark J

    2014-01-01

    In surface and interstitial high-dose-rate brachytherapy with either 60 Co, 192 Ir, or 169 Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields. Results were corrected to account for a realistic clinical case with multiple dwell positions. The range of the high backscatter dose enhancement in water is 3 mm for 60 Co and 1 mm for both 192 Ir and 169 Yb. Transmission data for 60 Co and 192 Ir are smaller than those reported by Papagiannis et al (2008 Med. Phys. 35 4898–4906) for brachytherapy facility shielding; for 169 Yb, the difference is negligible. In conclusion, the backscatter overdose produced by the lead shield can be avoided by just adding a few millimetres of bolus. Transmission data provided in this work as a function of lead thickness can be used to estimate healthy organ equivalent dose saving. Use of a lead shield is justified. (paper)

  10. Non-uniform dwell times in line source high dose rate brachytherapy: physical and radiobiological considerations

    International Nuclear Information System (INIS)

    Jones, B.; Tan, L.T.; Freestone, G.; Bleasdale, C.; Myint, S.; Littler, J.

    1994-01-01

    The ability to vary source dwell times in high dose rate (HDR) brachytherapy allows for the use of non-uniform dwell times along a line source. This may have advantages in the radical treatment of tumours depending on individual tumour geometry. This study investigates the potential improvements in local tumour control relative to adjacent normal tissue isoeffects when intratumour source dwell times are increased along the central portion of a line source (technique A) in radiotherapy schedules which include a relatively small component of HDR brachytherapy. Such a technique is predicted to increase the local control for tumours of diameters ranging between 2 cm and 4 cm by up to 11% compared with a technique in which there are uniform dwell times along the line source (technique B). There is no difference in the local control rates for the two techniques when used to treat smaller tumours. Normal tissue doses are also modified by the technique used. Technique A produces higher normal tissue doses at points perpendicular to the centre of the line source and lower dose at points nearer the ends of the line source if the prescription point is not in the central plane of the line source. Alternatively, if the dose is prescribed at a point in the central plane of the line source, the dose at all the normal tissue points are lower when technique A is used. (author)

  11. A method for verification of treatment times for high-dose-rate intraluminal brachytherapy treatment

    Directory of Open Access Journals (Sweden)

    Muhammad Asghar Gadhi

    2016-06-01

    Full Text Available Purpose: This study was aimed to increase the quality of high dose rate (HDR intraluminal brachytherapy treatment. For this purpose, an easy, fast and accurate patient-specific quality assurance (QA tool has been developed. This tool has been implemented at Bahawalpur Institute of Nuclear Medicine and Oncology (BINO, Bahawalpur, Pakistan.Methods: ABACUS 3.1 Treatment planning system (TPS has been used for treatment planning and calculation of total dwell time and then results were compared with the time calculated using the proposed method. This method has been used to verify the total dwell time for different rectum applicators for relevant treatment lengths (2-7 cm and depths (1.5-2.5 cm, different oesophagus applicators of relevant treatment lengths (6-10 cm and depths (0.9 & 1.0 cm, and a bronchus applicator for relevant treatment lengths (4-7.5 cm and depth (0.5 cm.Results: The average percentage differences between treatment time TM with manual calculation and as calculated by the TPS is 0.32% (standard deviation 1.32% for rectum, 0.24% (standard deviation 2.36% for oesophagus and 1.96% (standard deviation 0.55% for bronchus, respectively. These results advocate that the proposed method is valuable for independent verification of patient-specific treatment planning QA.Conclusion: The technique illustrated in the current study is an easy, simple, quick and useful for independent verification of the total dwell time for HDR intraluminal brachytherapy. Our method is able to identify human error-related planning mistakes and to evaluate the quality of treatment planning. It enhances the quality of brachytherapy treatment and reliability of the system.

  12. Comparison of high-dose-rate and low-dose-rate brachytherapy in the treatment of endometrial carcinoma

    International Nuclear Information System (INIS)

    Fayed, Alaa; Mutch, David G.; Rader, Janet S.; Gibb, Randall K.; Powell, Matthew A.; Wright, Jason D.; El Naqa, Issam; Zoberi, Imran; Grigsby, Perry W.

    2007-01-01

    Purpose: To compare the outcomes for endometrial carcinoma patients treated with either high-dose-rate (HDR) or low-dose-rate (LDR) brachytherapy. Methods and Materials: This study included 1,179 patients divided into LDR (1,004) and HDR groups (175). Patients with International Federation of Gynecology and Obstetrics (FIGO) surgical Stages I-III were included. All patients were treated with postoperative irradiation. In the LDR group, the postoperative dose applied to the vaginal cuff was 60-70 Gy surface doses to the vaginal mucosa. The HDR brachytherapy prescription was 6 fractions of 2 Gy each to a depth of 0.5 cm from the surface of the vaginal mucosa. Overall survival, disease-free survival, local control, and complications were endpoints. Results: For all stages combined, the overall survival, disease-free survival, and local control at 5 years in the LDR group were 70%, 69%, and 81%, respectively. For all stages combined, the overall survival, disease-free survival, and local control at 5 years in the HDR group were 68%, 62%, and 78%, respectively. There were no significant differences in early or late Grade III and IV complications in the HDR or LDR groups. Conclusion: Survival outcomes, pelvic tumor control, and Grade III and IV complications were not significantly different in the LDR brachytherapy group compared with the HDR group

  13. High-dose rate brachytherapy in the treatment of prostate cancer: acute toxicity and biochemical behavior analysis

    International Nuclear Information System (INIS)

    Esteves, Sergio Carlos Barros; Oliveira, Antonio Carlos Zuliani de; Cardoso, Herbeni; Tagawa, Eduardo Komai; Castelo, Roberto; D'Imperio, Marcio

    2006-01-01

    Objective: this study focuses on the biochemical response of the following variables: prostate volume, prostate-specific antigen (PSA) value, Gleason scores, staging, the risk of the disease, and hormone therapy. Objective: in the period between February of 1998 and July of 2001, 46 patients with prostate cancer were treated with radiotherapy, in a combination of teletherapy and high-dose rate (HDR) brachytherapy. The age ranged from 51 to 79 years (averaging 66.4 years). T1c stage was the most frequent one: 30 (65%). The Gleason score was below 7 in 78% of the patients. PSA ranged from 3.4 to 33.3, being below 10 in 39% of the cases. The average prostatic volume was 32.3 cc. Twenty-eight percent of the patients received hormone therapy. Teletherapy dose ranged from 45 to 50.4 Gy, associated to four fractions of 4 Gy of HDR brachytherapy. Results: the follow-up period varied from 6 to 43 months. Four patients missed the follow-up and four died (one due to the disease). Out of the 39 patients that were analyzed, 76% presented a less than 1.5 PSA. None of the analyzed variables were found to be of statistical significance (p > 0.05) regarding biochemical control. Conclusion: the use of HDR brachytherapy was found to be effective in the treatment of prostate cancer and, in this study, the variables considered as prognostic factors did not interfere in the biochemical control. (author)

  14. High dose rate brachytherapy for medically inoperable stage I endometrial cancer

    International Nuclear Information System (INIS)

    Petereit, Daniel G.; Sarkaria, Jann N.; Schink, Julian; Springman, Scott R.; Kinsella, Timothy J.; Buchler, Dolores A.

    1995-01-01

    Purpose/Objective: To determine the efficacy of high dose rate (HDR) brachytherapy in patients with medically inoperable endometrial cancer clinically confined to the corpus. Materials and Methods: Forty-two patients with endometrial cancer and an intact uterus have been treated since 1989 with HDR brachytherapy. Twenty-six patients with medically inoperable Stage I disease were treated with radiation alone and form the basis of this study. Obesity was assessed using the body mass index (BMI kg/m 2 ) scale. Patients with a BMI above 28 were considered obese and those above 35 morbidly obese, per standard anesthesia guidelines. Brachytherapy was delivered in 5 HDR insertions, 1 week apart, without any external beam radiation. The following doses were delivered per insertion: 5.7 Gy to point S, 7.0 Gy to point W, 8.2 Gy to the vaginal surface and 9.2 Gy to point M. Point M represents the conventional point A dose, while points S and W are myometrial points. A single tandem with either ovoids or cylinders was placed, unless the uterine cavity would accommodate 2 tandems. All treatments were outpatient using intravenous fentanyl and midazolam for sedation. Pelvic ultrasound was commonly used at the time of brachytherapy to verify tandem placement. Three year clinical endpoints were calculated using the Kaplan Meier method. Results: The median follow-up for the study cohort was 21 months with follow-up greater than 36 months in 11 patients. Seventeen of the 26 patients were inoperable due to morbid obesity (median weight and BMI; 316 lbs and 55 kg/m 2 , respectively); the other patients had poor cardiopulmonary reserve ± obesity. The median age, KPS (Karnofsky Performance Status), weight, ASA (American Society of Anesthesiologists' Physical Class System) and BMI were 63 yrs, 80%, 285 lbs, 3 and 49 kg/m 2 , respectively. Two patients with an ASA of 3 and 4 died from acute cardio-pulmonary events within 30 days of the last insertion, emphasizing the need for accurate pre

  15. Endoluminal high dose rate brachytherapy in the treatment of primary and recurrent bronchogenic tree malignancies

    Directory of Open Access Journals (Sweden)

    Maria Fortunato

    2009-03-01

    Full Text Available Introduction: Locally advanced tumours as the initial form of presentation of tumours in the bronchial tree are not a rare event. Bronchogenic recurrence is frequent in the natural history of some tumours. The choice of therapeutic options from the raft available depends on such variables as initial therapy, place of recurrence, symptoms and patient's physical status. Aim: To demonstrate the advantages of endoluminal brachytherapy (EBT with high dose rate (HDR in primary and recurrent tumour of the bronchial tree. Material and methods: A retrospective study of seven patients (pts with primary tumours of the colon, trachea and lung. Tracheobronchial recurrence (trachea, two pts, bronchus, five pts occurred betweenMarch 2003 and September 2004. Patients under-went EBT with HDR for primary or recurrent therapy in association with external radiotherapy, laser therapy and chemotherapy with palliative or curative intention. EBT with HDR doses of 5 to 7 Gy in 2 to 4 fractions at 1 cm from the source axis were given. Treatment included endoluminal application of Ir192 with a French 6 catheter. Results: There was symptomatic relief related to reduction of tumour in six of the seven patients treated. In one of the six patients studied, there was progression of the local disease between the second and third fractions of the treatment (obstruction of the trachea. In a mean follow up of 17 (2-40 months between EBT and this study, three patients are alive, one has no evidence of disease while two have had bronchial recurrence, four patients have died, one after massive haemoptysis and three due to disease progression. Discussion and conclusions: Patients undergoing brachytherapy for symptomatic primary tumours or endobronchial recurrence show good tolerance, important symptom relief and improved quality of life. Despite the small size of our sample, it is clear that EBT with HDR plays an important role in the palliative/curative treatment of these patients

  16. Adjuvant high-dose-rate brachytherapy after external beam radiotherapy in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Oezyar, Enis; Yildz, Ferah; Akyol, Fadil H.; Atahan, I. Lale

    2002-01-01

    Purpose: To compare the local control and survival rates obtained with either external beam radiation therapy (ERT) and adjuvant high-dose-rate (HDR) brachytherapy (BRT) or ERT alone in patients with nasopharyngeal cancer. Methods and Materials: Between December 1993 and December 1999, 144 patients (106 male, 38 female) with the diagnosis of nasopharyngeal cancer were treated with either ERT and adjuvant HDR BRT (Group A) or ERT alone (Group B) at our department. BRT was not applied in 38 patients for the following reasons: (1) Unit was unavailable (n=13), (2) Patient was younger than 18 years (n=17), (3) Patient received accelerated hyperfractionated ERT (n=6), and (4) Patient refused BRT (n=2). The median age for whole group was 43 (range: 9-82 years). According to the AJCC-1997 staging system, there were 11 (7.6%), 35 (24.3%), 38 (26.4%), and 60 (41.7%) patients in Stage I, II, III, and IV, respectively. There were 57 (39.6%) patients with T1, 41 (28.5%) with T2, 20 (13.9%) with T3, and 26 (18.1%) with T4 tumors. Histopathologic diagnosis was WHO 2-3 in 137 (95.2%) patients. ERT doses ranged between 58.8 and 74 Gy (median: 66 Gy). There were significantly more patients with young age, N2 status, and Stage III disease in Group B and with Stage II disease in Group A. Significantly more patients received chemotherapy in Group B. BRT with an HDR 192 Ir microSelectron afterloading unit was delivered in 106 patients at the conclusion of ERT using a single-channel nasal applicator. Dose was prescribed at 1 cm from the source, and total dose of 12 Gy in 3 fractions on 3 consecutive days was given immediately after ERT. Besides radiotherapy, 82 (56.9%) patients received cisplatin-based chemotherapy, as well. Follow-up time ranged between 12 and 80 months (median: 32 months). Results: The two groups were comparable in terms of local recurrence, locoregional failure, regional failure, and rate of distant metastasis. Local failure was observed in 11 (10.3%) out of 106

  17. Implementation of High-Dose-Rate Brachytherapy and Androgen Deprivation in Patients With Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lilleby, Wolfgang, E-mail: wolfgang.lilleby@ous-hf.no [Cancer Clinic, Oslo University Hospital, Norwegian Radiumhospital, Department of Radiotherapy and Oncology, Oslo (Norway); Tafjord, Gunnar; Raabe, Nils K. [Cancer Clinic, Oslo University Hospital, Norwegian Radiumhospital, Department of Radiotherapy and Oncology, Oslo (Norway)

    2012-07-01

    Purpose: To evaluate outcome (overall survival [OS], the actuarial 5-year cancer-specific survival [CSS], disease-free survival [DFS], biochemical failure-free survival [BFS]), complications and morbidity in patients treated with high-dose-rate brachytherapy (HDR-BT) boost and hormonal treatment with curative aims. Methods: Between 2004 and 2009, 275 prospectively followed pN0/N0M0 patients were included: 19 patients (7%) with T2, Gleason score 7 and prostate-specific antigen (PSA) <10 and 256 patients (93%) with T3 or Gleason score 8-10 or PSA >20 received multimodal treatment with conformal four-field radiotherapy (prostate/vesiculae 2 Gy Multiplication-Sign 25) combined with HDR-BT (iridium 192; prostate 10 Gy Multiplication-Sign 2) with long-term androgen deprivation therapy (ADT). Results: After a median observation time of 44.2 months (range, 10.4-90.5 months) 12 patients had relapsed clinically and/or biochemically and 10 patients were dead, of which 2 patients died from prostate cancer. Five-year estimates of BFS, CSS, DFS, and OS rates were 98.5%, 99.3%, 95.6%, and 96.3%, respectively. None of the patients with either Gleason score <8 or with intermediate risk profile had relapsed. The number of HDR-BT treatments was not related to outcome. Despite of age (median, 65.7 years; range, 45.7-77 years) and considerable pretreatment comorbidity in 39 of 275 patients, Genitourinary treatment-related morbidity was moderate with long-lasting Radiation Therapy Oncology Group Grade 2 voiding problems in 26 patients (9.5%) and occasionally mucous discharge in 20 patients (7%), none with Grade >2 for gastrointestinal at follow-up. Complications during implantations were related to pubic arch interference (4 patients) and lithotomy time, causing 2 patients to develop compartment syndrome. Conclusion: Despite still preliminary observations, our 5-year outcome estimates favor the implementation of high-dose-rate brachytherapy in high-risk patients combined with conformal

  18. High dose rate brachytherapy for carcinoma of the cervix: risk factors for late rectal complications

    International Nuclear Information System (INIS)

    Uno, Takashi; Itami, Jun; Aruga, Moriyo; Kotaka, Kikuo; Fujimoto, Hajime; Minoura, Shigeki

    1996-01-01

    Purpose/Objective: To determine the incidence of late rectal complications in patients treated with high dose rate brachytherapy for FIGO stage IIB, IIIB carcinoma of the uterine cervix, and to evaluate the treatment factors associated with an increased probability of treatment complications. Materials and Methods: Records of 100 patients with FIGO IIB or IIIB cervical carcinoma treated with definitive irradiation using high dose rate intracavitary brachytherapy (HDR-ICR) between 1977 and 1994 were retrospectively reviewed. For each HDR-ICR session, 6 Gy isodose volume was reconstructed three dimensionally and the following three parameters were determined to represent this isodose volume, length (L); maximum longitudinal distance of 6 Gy isodose area in an oblique frontal plane containing the intrauterine applicator, width (W); maximum width of 6 Gy isodose area in the same plane, height (H); maximum dimension of 6 Gy isodose area perpendicular to the intrauterine applicator determined in the oblique sagittal plane. Point P/Q (2 cm ventral/dorsal from the proximal retention point of the intrauterine source) and point R/S (2 cm ventral/dorsal from the midpoint of the ovoid sources) were also defined retrospectively and HDR-ICR dose at these points were calculated. Statistical analyses were performed to determine the treatment factors predictive of late rectal complications. Results: The 5-year cumulative cause-specific disease-free survival rate was 50% for all, 74% for Stage IIB, and 38% for Stage IIIB, with a significant difference between two FIGO Stages (p=0.0004). Of patients treated for both stages, 30% and 36% had experienced moderate to severe (Grade 2-4) complications at 3 and 5 years, respectively. Average H value (p=0.013) and cumulative point S dose by HDR-ICR (p=0.020) were significantly correlated with the incidence of late rectal complications (Student's t-test), whereas these factors did not significantly affect the probability of pelvic control. No

  19. Radioablation of adrenal gland malignomas with interstitial high-dose-rate brachytherapy. Efficacy and outcome

    Energy Technology Data Exchange (ETDEWEB)

    Mohnike, K. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Magdeburg (Germany); DTZ am Frankfurter Tor, Berlin (Germany); Neumann, K.; Seidensticker, M.; Seidensticker, R.; Pech, M.; Streitparth, T.; Ricke, J. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Magdeburg (Germany); Hass, P.; Gademann, G. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Strahlentherapie, Magdeburg (Germany); Klose, S. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Nieren- und Hochdruckkrankheiten, Diabetologie und Endokrinologie, Magdeburg (Germany); Garlipp, B.; Benckert, C. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Allgemein-, Viszeral- und Gefaesschirurgie, Magdeburg (Germany); Wendler, J.J.; Liehr, U.B.; Schostak, M. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Urologie und Kinderurologie, Magdeburg (Germany); Goeppner, D. [Universitaetsklinikum Magdeburg A.oe.R., Otto-von-Guericke-Universitaet, Klinik fuer Dermatologie, Magdeburg (Germany)

    2017-08-15

    To assess the efficacy, safety, and outcome of image-guided high-dose-rate (HDR) brachytherapy in patients with adrenal gland metastases (AGM). From January 2007 to April 2014, 37 patients (7 female, 30 male; mean age 66.8 years, range 41.5-82.5 years) with AGM from different primary tumors were treated with CT-guided HDR interstitial brachytherapy (iBT). Primary endpoint was local tumor control (LTC). Secondary endpoints were time to untreatable progression (TTUP), time to progression (TTP), overall survival (OS), and safety. In a secondary analysis, risk factors with an influence on survival were identified. The median biological equivalent dose (BED) was 37.4 Gy. Mean LTC after 12 months was 88%; after 24 months this was 74%. According to CTCAE criteria, one grade 3 adverse event occurred. Median OS after first diagnosis of AGM was 18.3 months. Median OS, TTUP, and TTP after iBT treatment were 11.4, 6.6, and 3.5 months, respectively. Uni- and multivariate Cox regression analyses revealed significant influences of synchronous disease, tumor diameter, and the total number of lesions on OS or TTUP or both. Image-guided HDR-iBT is safe and effective. Treatment- and primary tumor-independent features influenced survival of patients with AGM after HDR-iBR treatment. (orig.) [German] Beurteilung der Effektivitaet, Sicherheit und Ergebnisse nach bildgefuehrter High-dose-rate-(HDR-)Brachytherapie bei Patienten mit Nebennierenmetastasen. Von Januar 2007 bis April 2014 wurden 37 Patienten (7 weiblich, 30 maennlich; mittleres Alter 66,8 Jahre, Spanne 41,5-82,5 Jahre) mit Nebennierenmetastasen verschiedener Primarien mit CT-gesteuerter interstitieller HDR-Brachytherapie (iBT) behandelt. Der primaere Endpunkt war die lokale Tumorkontrolle (LTC). Sekundaere Endpunkte umfassten die Zeit bis zum nicht mehr behandelbaren Progress (TTUP), die Zeit bis zum Progress (TTP), das Gesamtueberleben (OS) und die Sicherheit der Methode. In einer sekundaeren Analyse wurden Risikofaktoren

  20. Impact of catheter reconstruction error on dose distribution in high dose rate intracavitary brachytherapy and evaluation of OAR doses

    International Nuclear Information System (INIS)

    Thaper, Deepak; Shukla, Arvind; Rathore, Narendra; Oinam, Arun S.

    2016-01-01

    In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this study is to evaluate the impact of catheter reconstruction error on dose distribution in CT based intracavitary brachytherapy planning and evaluation of its effect on organ at risk (OAR) like bladder, rectum and sigmoid and target volume High risk clinical target volume (HR-CTV)

  1. Automated high-dose rate brachytherapy treatment planning for a single-channel vaginal cylinder applicator

    Science.gov (United States)

    Zhou, Yuhong; Klages, Peter; Tan, Jun; Chi, Yujie; Stojadinovic, Strahinja; Yang, Ming; Hrycushko, Brian; Medin, Paul; Pompos, Arnold; Jiang, Steve; Albuquerque, Kevin; Jia, Xun

    2017-06-01

    High dose rate (HDR) brachytherapy treatment planning is conventionally performed manually and/or with aids of preplanned templates. In general, the standard of care would be elevated by conducting an automated process to improve treatment planning efficiency, eliminate human error, and reduce plan quality variations. Thus, our group is developing AutoBrachy, an automated HDR brachytherapy planning suite of modules used to augment a clinical treatment planning system. This paper describes our proof-of-concept module for vaginal cylinder HDR planning that has been fully developed. After a patient CT scan is acquired, the cylinder applicator is automatically segmented using image-processing techniques. The target CTV is generated based on physician-specified treatment depth and length. Locations of the dose calculation point, apex point and vaginal surface point, as well as the central applicator channel coordinates, and the corresponding dwell positions are determined according to their geometric relationship with the applicator and written to a structure file. Dwell times are computed through iterative quadratic optimization techniques. The planning information is then transferred to the treatment planning system through a DICOM-RT interface. The entire process was tested for nine patients. The AutoBrachy cylindrical applicator module was able to generate treatment plans for these cases with clinical grade quality. Computation times varied between 1 and 3 min on an Intel Xeon CPU E3-1226 v3 processor. All geometric components in the automated treatment plans were generated accurately. The applicator channel tip positions agreed with the manually identified positions with submillimeter deviations and the channel orientations between the plans agreed within less than 1 degree. The automatically generated plans obtained clinically acceptable quality.

  2. Online pretreatment verification of high-dose rate brachytherapy using an imaging panel.

    Science.gov (United States)

    Fonseca, Gabriel P; Podesta, Mark; Bellezzo, Murillo; Van den Bosch, Michiel R; Lutgens, Ludy; Vanneste, Ben G L; Voncken, Robert; Van Limbergen, Evert J; Reniers, Brigitte; Verhaegen, Frank

    2017-07-07

    Brachytherapy is employed to treat a wide variety of cancers. However, an accurate treatment verification method is currently not available. This study describes a pre-treatment verification system that uses an imaging panel (IP) to verify important aspects of the treatment plan. A detailed modelling of the IP was only possible with an extensive calibration performed using a robotic arm. Irradiations were performed with a high dose rate (HDR) 192 Ir source within a water phantom. An empirical fit was applied to measure the distance between the source and the detector so 3D Cartesian coordinates of the dwell positions can be obtained using a single panel. The IP acquires 7.14 fps to verify the dwell times, dwell positions and air kerma strength (Sk). A gynecological applicator was used to create a treatment plan that was registered with a CT image of the water phantom used during the experiments for verification purposes. Errors (shifts, exchanged connections and wrong dwell times) were simulated to verify the proposed verification system. Cartesian source positions (panel measurement plane) have a standard deviation of about 0.02 cm. The measured distance between the source and the panel (z-coordinate) have a standard deviation up to 0.16 cm and maximum absolute error of  ≈0.6 cm if the signal is close to sensitive limit of the panel. The average response of the panel is very linear with Sk. Therefore, Sk measurements can be performed with relatively small errors. The measured dwell times show a maximum error of 0.2 s which is consistent with the acquisition rate of the panel. All simulated errors were clearly identified by the proposed system. The use of IPs is not common in brachytherapy, however, it provides considerable advantages. It was demonstrated that the IP can accurately measure Sk, dwell times and dwell positions.

  3. The prediction of late rectal complications in patients treated with high dose-rate brachytherapy for carcinoma of the cervix

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Souhami, Luis; Roman, Ted N.; Chappell, Rick; Evans, Michael D.C.; Fowler, Jack F.

    1997-01-01

    Purpose: The aim of this work is to investigate an unusually high rate of late rectal complications in a group of 43 patients treated with concomitant irradiation and chemotherapy for carcinoma of the cervix between December 1988 and April 1991, with a view to identifying predictive factors. Methods and Materials: The biologically effective dose received by each patient to the rectal reference point defined by the International Commission of Radiation Units and Measurements, Report 38, were calculated. Radiotherapy consisted of 46 Gy external beam irradiation plus three high dose-rate intracavitary treatments of 10 Gy each prescribed to point A. Cisplatin 30 mg/m 2 was given weekly throughout the duration of the irradiation. The results have been compared to data from 119 patients treated with irradiation alone to assess the confounding effect of the cisplatin. Results: The relationship between the biologically effective dose delivered to the rectal reference point and the development of late complications shows a strong dose-response with a threshold for complications occurring at approximately 125 Gy 3 corresponding to a brachytherapy dose of approximately 8 Gy per fraction. This value is approximately the same biologically effective dose threshold as that found for external beam irradiation in the head and neck region. The data from the group of patients treated without cisplatin is comparable to the data from the first group of patients in the lower dose ranges; the higher doses were not used and thus are not available for comparison. Conclusion: Using the linear quadratic model applied to our clinical results, we have established a threshold for late rectal complications for patients treated with external beam irradiation and high dose-rate brachytherapy for carcinoma of the cervix. This threshold is consistent with similar data for external beam irradiation in the head and neck region

  4. CT-guided high-dose-rate brachytherapy of unresectable hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Collettini, Federico; Schreiber, Nadja; Schnapauff, Dirk; Denecke, Timm; Hamm, Bernd; Gebauer, Bernhard; Wust, Peter; Schott, Eckart

    2015-01-01

    The purpose of the present study was to evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) in patients with unresectable hepatocellular carcinoma (HCC). Over a 6-year period, 98 patients with 212 unresectable HCC underwent CT-HDRBT applying a 192 Ir source at our institution. Magnetic resonance imaging (MRI) follow-up was performed 6 weeks after the intervention and then every 3 months. The primary endpoint was local tumor control (LTC); secondary endpoints included progression-free survival (PFS) and overall survival (OS). Patients were available for MRI evaluation for a mean follow-up of 23.1 months (range 4-64 months; median 20 months). Mean tumor diameter was 5 cm (range 1.8-12 cm). Eighteen of 212 (8.5 %) tumors showed local progression after a mean LTC of 21.1 months. In all, 67 patients (68.4 %) experienced distant tumor progression. The mean PFS was 15.2 months. Forty-six patients died during the follow-up period. Median OS was 29.2 months. Actuarial 1-, 2-, and 3-year OS rates were 80, 62, and 46 %, respectively. CT-HDRBT is an effective therapy to attain local tumor control in patients with unresectable HCC. Prospective randomized studies comparing CT-HDRBT with the standard treatments like Radiofrequency ablation (RFA) and chemoembolization (TACE) are mandatory. (orig.) [de

  5. A phantom for verification of dwell position and time of a high dose rate brachytherapy source

    International Nuclear Information System (INIS)

    Madebo, M.; Kron, T.; Pillainayagam, J.; Franich, R.

    2012-01-01

    Accuracy of dwell position and reproducibility of dwell time are critical in high dose rate (HDR) brachytherapy. A phantom was designed to verify dwell position and dwell time reproducibility for an Ir-192 HDR stepping source using Computed Radiography (CR). The central part of the phantom, incorporating thin alternating strips of lead and acrylic, was used to measure dwell positions. The outer part of the phantom features recesses containing different absorber materials (lead, aluminium, acrylic and polystyrene foam), and was used for determining reproducibility of dwell times. Dwell position errors of <1 mm were easily detectable using the phantom. The effect of bending a transfer tube was studied with this phantom and no change of clinical significance was observed when varying the curvature of the transfer tube in typical clinical scenarios. Changes of dwell time as low as 0.1 s, the minimum dwell time of the treatment unit, could be detected by choosing dwell times over the four materials that produce identical exposure at the CR detector.

  6. Towards enabling ultrasound guidance in cervical cancer high-dose-rate brachytherapy

    Science.gov (United States)

    Wong, Adrian; Sojoudia, Samira; Gaudet, Marc; Yap, Wan Wan; Chang, Silvia D.; Abolmaesumi, Purang; Aquino-Parsons, Christina; Moradi, Mehdi

    2014-03-01

    MRI and Computed Tomography (CT) are used in image-based solutions for guiding High Dose Rate (HDR) brachytherapy treatment of cervical cancer. MRI is costly and CT exposes the patients to ionizing radiation. Ultrasound, on the other hand, is affordable and safe. The long-term goal of our work is to enable the use of multiparametric ultrasound imaging in image-guided HDR for cervical cancer. In this paper, we report the development of enabling technology for ultrasound guidance and tissue typing. We report a system to obtain the 3D freehand transabdominal ultrasound RF signals and B-mode images of the uterus, and a method for registration of ultrasound to MRI. MRI and 3D ultrasound images of the female pelvis were registered by contouring the uterus in the two modalities, creating a surface model, followed by rigid and B-spline deformable registration. The resulting transformation was used to map the location of the tumor from the T2-weighted MRI to ultrasound images and to determine cancerous and normal areas in ultrasound. B-mode images show a contrast for cancer vs. normal tissue. Our study shows the potential and the challenges of ultrasound imaging in guiding cervical cancer treatments.

  7. A quality assurance (QA) system with a web camera for high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Hirose, Asako; Ueda, Yoshihiro; Ohira, Shingo

    2016-01-01

    The quality assurance (QA) system that simultaneously quantifies the position and duration of an 192 Ir source (dwell position and time) was developed and the performance of this system was evaluated in high-dose-rate brachytherapy. This QA system has two functions to verify and quantify dwell position and time by using a web camera. The web camera records 30 images per second in a range from 1,425 mm to 1,505 mm. A user verifies the source position from the web camera at real time. The source position and duration were quantified with the movie using in-house software which was applied with a template-matching technique. This QA system allowed verification of the absolute position in real time and quantification of dwell position and time simultaneously. It was evident from the verification of the system that the mean of step size errors was 0.3±0.1 mm and that of dwell time errors 0.1 ± 0.0 s. Absolute position errors can be determined with an accuracy of 1.0 mm at all dwell points in three step sizes and dwell time errors with an accuracy of 0.1% in more than 10.0 s of the planned time. This system is to provide quick verification and quantification of the dwell position and time with high accuracy at various dwell positions without depending on the step size. (author)

  8. High dose rate brachytherapy in patients with local recurrences after radiotherapy of non-small cell lung cancer

    NARCIS (Netherlands)

    Sutedja, G.; Baris, G.; Schaake-Koning, C.; van Zandwijk, N.

    1992-01-01

    Thirty-one patients with recurrences of locally advanced Stage III lung cancer were treated with high dose rate brachytherapy. All patients had previously received a full course external beam irradiation. All treatments were performed under topical anaesthesia and took 6-14 min depending on the

  9. Limitations of the TG-43 formalism for skin high-dose-rate brachytherapy dose calculations

    Energy Technology Data Exchange (ETDEWEB)

    Granero, Domingo, E-mail: dgranero@eresa.com [Department of Radiation Physics, ERESA, Hospital General Universitario, 46014 Valencia (Spain); Perez-Calatayud, Jose [Radiotherapy Department, La Fe University and Polytechnic Hospital, Valencia 46026 (Spain); Vijande, Javier [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and IFIC (UV-CSIC), Paterna 46980 (Spain); Ballester, Facundo [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2014-02-15

    Purpose: In skin high-dose-rate (HDR) brachytherapy, sources are located outside, in contact with, or implanted at some depth below the skin surface. Most treatment planning systems use the TG-43 formalism, which is based on single-source dose superposition within an infinite water medium without accounting for the true geometry in which conditions for scattered radiation are altered by the presence of air. The purpose of this study is to evaluate the dosimetric limitations of the TG-43 formalism in HDR skin brachytherapy and the potential clinical impact. Methods: Dose rate distributions of typical configurations used in skin brachytherapy were obtained: a 5 cm × 5 cm superficial mould; a source inside a catheter located at the skin surface with and without backscatter bolus; and a typical interstitial implant consisting of an HDR source in a catheter located at a depth of 0.5 cm. Commercially available HDR{sup 60}Co and {sup 192}Ir sources and a hypothetical {sup 169}Yb source were considered. The Geant4 Monte Carlo radiation transport code was used to estimate dose rate distributions for the configurations considered. These results were then compared to those obtained with the TG-43 dose calculation formalism. In particular, the influence of adding bolus material over the implant was studied. Results: For a 5 cm × 5 cm{sup 192}Ir superficial mould and 0.5 cm prescription depth, dose differences in comparison to the TG-43 method were about −3%. When the source was positioned at the skin surface, dose differences were smaller than −1% for {sup 60}Co and {sup 192}Ir, yet −3% for {sup 169}Yb. For the interstitial implant, dose differences at the skin surface were −7% for {sup 60}Co, −0.6% for {sup 192}Ir, and −2.5% for {sup 169}Yb. Conclusions: This study indicates the following: (i) for the superficial mould, no bolus is needed; (ii) when the source is in contact with the skin surface, no bolus is needed for either {sup 60}Co and {sup 192}Ir. For

  10. High-dose-rate afterloading brachytherapy in carcinoma of the cervix: an experience of 1992 patients

    International Nuclear Information System (INIS)

    Lorvidhaya, Vicharn; Tonusin, Anun; Changwiwit, Witit; Chitapanarux, Imjai; Srisomboon, Jatupol; Wanwilairat, Somsak; Chawapun, Nisa; Sukthomya, Vimol

    2000-01-01

    Purpose: To report the results of radiation therapy in carcinoma of the cervix treated by external irradiation and high-dose-rate (HDR) intracavitary brachytherapy. Methods and Materials: This is a retrospective analysis of 2063 patients with histologically proven carcinoma of the cervix treated by external irradiation and HDR intracavitary brachytherapy between March 1985-December 1991. The Kaplan-Meier method was used for survival and disease-free survival analysis. Late complications in the bowel and bladder were calculated actuarially. Results: There were 71 patients who did not complete the course of irradiation so only 1992 patients were retrospectively analyzed for survival. There were 2 patients (0.1%) in Stage IA, 211 (10.2%) Stage IB, 225 (10.9%) in Stage IIA, 902 (43.7%) in Stage IIB, 14 (0.7%) in Stage IIIA, 675 (32.7%) in Stage IIIB, 16 (0.8%) in Stage IVA, and 16 (0.8%) in Stage IVB. The median follow-up time was 96 months. The actuarial 5-year disease-free survival rate was 79.5%, 70.0%, 59.4%, 46.1%, 32.3%, 7.8%, and 23.1% for Stage IB, IIA, IIB, IIIA, IIIB, IVA, and IVB respectively. The actuarial 5-year disease-free survival rate for Stage IB 1 and IB 2 squamous cell carcinoma was 88.7% and 67.0%. The actuarial 5-year overall survival rate was 86.3%, 81.1%, 73.0%, 50.3%, 47.8%, 7.8%, and 30.8% for Stage IB, IIA, IIB, IIIA, IIIB, IVA, and IVB respectively. Pattern of failure revealed 20.8% local recurrence, 18.7% distant metastases, and 4% in both. The late complication rate Grade 3 and 4 (RTOG) for bowel and bladder combined was 7.0% with 1.9% Grade 4. Conclusion: HDR brachytherapy used in this series produced pelvic control and survival rates comparable to other LDR series

  11. Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy.

    Directory of Open Access Journals (Sweden)

    Luciana Tourinho Campos

    Full Text Available The use of high-dose-rate brachytherapy is currently a widespread practice worldwide. The most common isotope source is 192Ir, but 60Co is also becoming available for HDR. One of main advantages of 60Co compared to 192Ir is the economic and practical benefit because of its longer half-live, which is 5.27 years. Recently, Eckert & Ziegler BEBIG, Germany, introduced a new afterloading brachytherapy machine (MultiSource®; it has the option to use either the 60Co or 192Ir HDR source. The source for the Monte Carlo calculations is the new 60Co source (model Co0.A86, which is referred to as the new BEBIG 60Co HDR source and is a modified version of the 60Co source (model GK60M21, which is also from BEBIG.The purpose of this work is to obtain the dosimetry parameters in accordance with the AAPM TG-43U1 formalism with Monte Carlo calculations regarding the BEBIG 60Co high-dose-rate brachytherapy to investigate the required treatment-planning parameters. The geometric design and material details of the source was provided by the manufacturer and was used to define the Monte Carlo geometry. To validate the source geometry, a few dosimetry parameters had to be calculated according to the AAPM TG-43U1 formalism. The dosimetry studies included the calculation of the air kerma strength Sk, collision kerma in water along the transverse axis with an unbounded phantom, dose rate constant and radial dose function. The Monte Carlo code system that was used was EGSnrc with a new cavity code, which is a part of EGS++ that allows calculating the radial dose function around the source. The spectrum to simulate 60Co was composed of two photon energies, 1.17 and 1.33 MeV. Only the gamma part of the spectrum was used; the contribution of the electrons to the dose is negligible because of the full absorption by the stainless-steel wall around the metallic 60Co. The XCOM photon cross-section library was used in subsequent simulations, and the photoelectric effect, pair

  12. High-Dose-Rate Brachytherapy Alone for Localized Prostate Cancer in Patients at Moderate or High Risk of Biochemical Recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Hoskin, Peter [Cancer Centre, Mount Vernon Hospital, Northwood, Middlesex (United Kingdom); Rojas, Ana, E-mail: arc03@btconnect.com [Cancer Centre, Mount Vernon Hospital, Northwood, Middlesex (United Kingdom); Lowe, Gerry; Bryant, Linda; Ostler, Peter; Hughes, Rob; Milner, Jessica; Cladd, Helen [Cancer Centre, Mount Vernon Hospital, Northwood, Middlesex (United Kingdom)

    2012-03-15

    Purpose: To evaluate genitourinary (GU) and gastrointestinal (GI) morbidity and biochemical control of disease in patients with localized prostate adenocarcinoma treated with escalating doses per fraction of high-dose rate brachytherapy alone. Methods and Materials: A total of 197 patients were treated with 34 Gy in four fractions, 36 Gy in four fractions, 31.5 Gy in three fractions, or 26 Gy in two fractions. Median follow-up times were 60, 54, 36, and 6 months, respectively. Results: Incidence of early Grade {>=} 3 GU morbidity was 3% to 7%, and Grade 4 was 0% to 4%. During the first 12 weeks, the highest mean International Prostate Symptom Score (IPSS) value was 14, and between 6 months and 5 years it was 8. Grade 3 or 4 early GI morbidity was not observed. The 3-year actuarial rate of Grade 3 GU was 3% to 16%, and was 3% to 7% for strictures requiring surgery (4-year rate). An incidence of 1% Grade 3 GI events was seen at 3 years. Late Grade 4 GU or GI events were not observed. At 3 years, 99% of patients with intermediate-risk and 91% with high-risk disease were free of biochemical relapse (log-rank p = 0.02). Conclusions: There was no significant difference in urinary and rectal morbidity between schedules. Biochemical control of disease in patients with intermediate and high risk of relapse was good.

  13. Needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer evaluated by repeated MRI.

    Science.gov (United States)

    Buus, Simon; Lizondo, Maria; Hokland, Steffen; Rylander, Susanne; Pedersen, Erik M; Tanderup, Kari; Bentzen, Lise

    To quantify needle migration and dosimetric impact in high-dose-rate brachytherapy for prostate cancer and propose a threshold for needle migration. Twenty-four high-risk prostate cancer patients treated with an HDR boost of 2 × 8.5 Gy were included. Patients received an MRI for planning (MRI1), before (MRI2), and after treatment (MRI3). Time from needle insertion to MRI3 was ∼3 hours. Needle migration was evaluated from coregistered images: MRI1-MRI2 and MRI1-MRI3. Dose volume histogram parameters from the treatment plan based on MRI1 were related to parameters based on needle positions in MRI2 or MRI3. Regression was used to model the average needle migration per implant and change in D90 clinical target volume, CTV prostate+3mm . The model fit was used for estimating the dosimetric impact in equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy. Needle migration was on average 2.2 ± 1.8 mm SD from MRI1-MRI2 and 5.0 ± 3.0 mm SD from MRI1-MRI3. D90 CTV prostate+3mm was robust toward average needle migration ≤3 mm, whereas for migration >3 mm D90 decreased by 4.5% per mm. A 3 mm of needle migration resulted in a decrease of 0.9, 1.7, 2.3, 4.8, and 7.6 equivalent dose in 2 Gy fractions for dose levels of 6, 8.5, 10, 15, and 19 Gy, respectively. Substantial needle migration in high-dose-rate brachytherapy occurs frequently in 1-3 hours following needle insertion. A 3-mm threshold of needle migration is proposed, but 2 mm may be considered for dose levels ≥15 Gy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Poulin, Eric; Fekete, Charles-Antoine Collins; Beaulieu, Luc; Létourneau, Mélanie; Fenster, Aaron; Pouliot, Jean

    2013-01-01

    Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then be generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the

  15. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Fekete, Charles-Antoine Collins; Beaulieu, Luc [Département de Physique, de Génie Physique et d’Optique et Centre de recherche sur le cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de Radio-Oncologie et Axe oncologie du Centre de Recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Létourneau, Mélanie [Département de Radio-Oncologie, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Ontario N6A 5K8 (United Kingdom); Pouliot, Jean [Department of Radiation Oncology, University of California San Francisco, Helen Diller Family Comprehensive Cancer Center, 1600 Divisadero Street, San Francisco, California 94143-1708 (United States)

    2013-11-15

    Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then be generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the

  16. TU-D-201-07: Severity Indication in High Dose Rate Brachytherapy Emergency Response Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Li, K [Associates in Medical Physics, Hagerstown, MD (United States); Rustad, F [Associates In Medical Physics, Lanham, MD (United States)

    2016-06-15

    Purpose: Understanding the corresponding dose to different staff during the High Dose Rate (HDR) Brachytherapy emergency response procedure could help to develop a strategy in efficiency and effective action. In this study, the variation and risk analysis methodology was developed to simulation the HDR emergency response procedure based on severity indicator. Methods: A GammaMedplus iX HDR unit from Varian Medical System was used for this simulation. The emergency response procedure was decomposed based on risk management methods. Severity indexes were used to identify the impact of a risk occurrence on the step including dose to patient and dose to operation staff by varying the time, HDR source activity, distance from the source to patient and staff and the actions. These actions in 7 steps were to press the interrupt button, press emergency shutoff switch, press emergency button on the afterloader keypad, turn emergency hand-crank, remove applicator from the patient, disconnect transfer tube and move afterloader from the patient, and execute emergency surgical recovery. Results: Given the accumulated time in second at the assumed 7 steps were 15, 5, 30, 15, 180, 120, 1800, and the dose rate of HDR source is 10 Ci, the accumulated dose in cGy to patient at 1cm distance were 188, 250, 625, 813, 3063, 4563 and 27063, and the accumulated exposure in rem to operator at outside the vault, 1m and 10cm distance were 0.0, 0.0, 0.1, 0.1, 22.6, 37.6 and 262.6. The variation was determined by the operators in action at different time and distance from the HDR source. Conclusion: The time and dose were estimated for a HDR unit emergency response procedure. It provided information in making optimal decision during the emergency procedure. Further investigation would be to optimize and standardize the responses for other emergency procedure by time-spatial-dose severity function.

  17. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications

    Energy Technology Data Exchange (ETDEWEB)

    Shwetha, Bondel [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Ravikumar, Manickam, E-mail: drravikumarm@gmail.com [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Supe, Sanjay S.; Sathiyan, Saminathan [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India); Lokesh, Vishwanath [Department of Radiotherapy, Kidwai, Memorial Institute of Oncology, Bangalore (India); Keshava, Subbarao L. [Department of Radiation Physics, Kidwai, Memorial Institute of Oncology, Bangalore (India)

    2012-04-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems.

  18. Obstructive urination problems after high-dose-rate brachytherapy boost treatment for prostate cancer are avoidable

    International Nuclear Information System (INIS)

    Kragelj, Borut

    2016-01-01

    Aiming at improving treatment individualization in patients with prostate cancer treated with combination of external beam radiotherapy and high-dose-rate brachytherapy to boost the dose to prostate (HDRB-B), the objective was to evaluate factors that have potential impact on obstructive urination problems (OUP) after HDRB-B. In the follow-up study 88 patients consecutively treated with HDRB-B at the Institute of Oncology Ljubljana in the period 2006-2011 were included. The observed outcome was deterioration of OUP (DOUP) during the follow-up period longer than 1 year. Univariate and multivariate relationship analysis between DOUP and potential risk factors (treatment factors, patients’ characteristics) was carried out by using binary logistic regression. ROC curve was constructed on predicted values and the area under the curve (AUC) calculated to assess the performance of the multivariate model. Analysis was carried out on 71 patients who completed 3 years of follow-up. DOUP was noted in 13/71 (18.3%) of them. The results of multivariate analysis showed statistically significant relationship between DOUP and anti-coagulation treatment (OR 4.86, 95% C.I. limits: 1.21-19.61, p = 0.026). Also minimal dose received by 90% of the urethra volume was close to statistical significance (OR = 1.23; 95% C.I. limits: 0.98-1.07, p = 0.099). The value of AUC was 0.755. The study emphasized the relationship between DOUP and anticoagulation treatment, and suggested the multivariate model with fair predictive performance. This model potentially enables a reduction of DOUP after HDRB-B. It supports the belief that further research should be focused on urethral sphincter as a critical structure for OUP

  19. Dosimetric evaluation of two treatment planning systems for high dose rate brachytherapy applications.

    Science.gov (United States)

    Shwetha, Bondel; Ravikumar, Manickam; Supe, Sanjay S; Sathiyan, Saminathan; Lokesh, Vishwanath; Keshava, Subbarao L

    2012-01-01

    Various treatment planning systems are used to design plans for the treatment of cervical cancer using high-dose-rate brachytherapy. The purpose of this study was to make a dosimetric comparison of the 2 treatment planning systems from Varian medical systems, namely ABACUS and BrachyVision. The dose distribution of Ir-192 source generated with a single dwell position was compared using ABACUS (version 3.1) and BrachyVision (version 6.5) planning systems. Ten patients with intracavitary applications were planned on both systems using orthogonal radiographs. Doses were calculated at the prescription points (point A, right and left) and reference points RU, LU, RM, LM, bladder, and rectum. For single dwell position, little difference was observed in the doses to points along the perpendicular bisector. The mean difference between ABACUS and BrachyVision for these points was 1.88%. The mean difference in the dose calculated toward the distal end of the cable by ABACUS and BrachyVision was 3.78%, whereas along the proximal end the difference was 19.82%. For the patient case there was approximately 2% difference between ABACUS and BrachyVision planning for dose to the prescription points. The dose difference for the reference points ranged from 0.4-1.5%. For bladder and rectum, the differences were 5.2% and 13.5%, respectively. The dose difference between the rectum points was statistically significant. There is considerable difference between the dose calculations performed by the 2 treatment planning systems. It is seen that these discrepancies are caused by the differences in the calculation methodology adopted by the 2 systems. Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  20. The status of low dose rate and future of high dose rate Cf-252 brachytherapy

    International Nuclear Information System (INIS)

    Rivard, M.J.; Wierzbicki, J.G.; Van den Heuvel, F.; Chuba, P.J.; Fontanesi, J.

    1997-12-01

    This work describes the current status of the US low dose rate (LDR) Cf-252 brachytherapy program. The efforts undertaken towards development of a high dose rate (HDR) remotely after loaded Cf-252 source, which can accommodate 1 mg or greater Cf-252, are also described. This HDR effort is a collaboration between Oak Ridge National Laboratory (ORNL), commercial remote after loader manufactures, the Gershenson Radiation Oncology Center (ROC), and Wayne State University. To achieve this goal, several advances in isotope chemistry and source preparation at ORNL must be achieved to yield a specific material source loading of greater than or equal 1 mg Cf-252 per mm3. Development work with both radioactive and non-radioactive stand-ins for Cf-252 have indicated the feasibility of fabricating such sources. As a result, the decreased catheter diameter and computer controlled source placement will permit additional sites (e.g. brain, breast, prostate, lung, parotid, etc.) to be treated effectively with Cf-252 sources. Additional work at the Radiochemical Engineering and Development Center (REDC) remains in source fabrication, after loader modification, and safe design. The current LDR Cf-252 Treatment Suite at the ROC is shielded and licensed to hold up to 1 mg of Cf-252. This was designed to maintain cumulative personnel exposure, both external to the room and in direct isotope handling, at less than 20 microSv/hr. However, cumulative exposure may be greatly decreased if a Cf-252 HDR unit is employed which would eliminate direct isotope handling and decrease treatment times from tilde 3 hours to an expected range of 3 to 15 minutes. Such a Cf-252 HDR source will also demonstrate improved dose distributions over current LDR treatments due to the ability to step the point-like source throughout the target volume and weight the dwell time accordingly

  1. Treatment of Recurrent Bronchial Carcinoma: The Role of High-Dose-Rate Endoluminal Brachytherapy

    International Nuclear Information System (INIS)

    Hauswald, Henrik; Stoiber, Eva; Rochet, Nathalie; Lindel, Katja; Grehn, Christian; Becker, Heinrich D.; Debus, Juergen; Harms, Wolfgang

    2010-01-01

    Purpose: This study's aim was to assess outcome and toxicity of high-dose-rate endoluminal brachytherapy (HDREB) for recurrent bronchial carcinoma. Methods and Materials: From 1987 to 2005, 41 patients were treated with HDREB for symptomatic recurrent bronchial carcinoma. All patients had previously undergone external beam radiotherapy (EBRT) with a median dose of 56 Gy (range, 30-70 Gy). The median HDREB dose applied was 15 Gy (range, 5-29 Gy). The median time interval between primary EBRT and reirradiation was 9 months (range, 2-54 months). Results: After a median follow-up of 6.7 months, the 6-, 12-, and 24-month overall survival rates were 58%, 18%, and 7%, respectively. The median overall survival time was 6.7 months. Local remission was achieved in 73% of patients (n = 30). A total of 24% of patients (n = 10) showed no response or progressive disease within 8 weeks after treatment. In 1 patient, treatment response was not documented. The 6-, 12-, and 24-month local control rates were 38%, 17%, and 3%, respectively. The median local progression-free survival time was 4 months (range, 1-23 months). Prognostic factors were a total dose of ≥15 Gy of HDREB (p = 0.029) and a Karnofsky performance score of ≥80% (p = 0.0012). The cause of death was locoregional progression in 27% of patients (n = 11), distant metastases in 24% of patients (n = 10), fatal hemorrhage in 15% of patients (n = 6), and other causes in 29% of patients (n = 12). None of the patients with locally controlled disease showed grade 3 or 4 late effects. Conclusions: Palliative treatment of symptomatic, locally recurrent bronchial carcinoma with HDREB can effectively relieve symptoms in the majority of patients while causing only few complications. Still, time to progression is short.

  2. Three-dimensional image-based high-dose-rate interstitial brachytherapy for mobile tongue cancer

    International Nuclear Information System (INIS)

    Yoshida, Ken; Takenaka, Tadashi; Akiyama, Hironori

    2014-01-01

    To investigate the influence of a 3D image-based treatment-planning method for high-dose-rate interstitial brachytherapy (HDR-ISBT) for mobile tongue cancer, we analyzed dose–volume histogram results for the clinical target volume (CTV) and the mandible. Between October 2010 and November 2011, one and four patients having T2 and T3 tumors, respectively, were treated with HDR-ISBT. Multiplane implantation using 9–15 treatment applicators was performed. Lugol's iodine staining, metal markers, ultrasonography, and magnetic resonance imaging were used to identify the contours of the gross tumor volume (defined as the CTV). The results of the image-based treatment plan were compared with those of the conventional simulated plan on the basis of a reference point 5 mm from the applicator position. The mean D90(CTV) and V100(CTV) were 112% of the prescribed dose (PD) and 98.1%PD, respectively, for the image-based plan, and 113%PD and 97.2%PD, respectively, for the conventional plan. The median CTV ref /V ref was 0.23 for the image-based plan and 0.16 for the conventional plan (P = 0.01). The mean D 0.1 cm 3 (mandible), D 1 cm 3 (mandible), and D 2 cm 3 (mandible) were 80.1%PD, 62.5%PD, and 55.7%PD, respectively, for the image-based plan, and 109.1%PD (P = 0.02), 82.4%PD (P = 0.005), and 74%PD (P = 0.004), respectively, for the conventional plan). Image-based treatment planning may achieve high-conformity radiotherapy for the CTV and decrease irradiated doses to the mandible. (author)

  3. Performance assessment of the BEBIG MultiSource® high dose rate brachytherapy treatment unit

    Science.gov (United States)

    Palmer, Antony; Mzenda, Bongile

    2009-12-01

    A comprehensive system characterisation was performed of the Eckert & Ziegler BEBIG GmbH MultiSource® High Dose Rate (HDR) brachytherapy treatment unit with an 192Ir source. The unit is relatively new to the UK market, with the first installation in the country having been made in the summer of 2009. A detailed commissioning programme was devised and is reported including checks of the fundamental parameters of source positioning, dwell timing, transit doses and absolute dosimetry of the source. Well chamber measurements, autoradiography and video camera analysis techniques were all employed. The absolute dosimetry was verified by the National Physical Laboratory, UK, and compared to a measurement based on a calibration from PTB, Germany, and the supplied source certificate, as well as an independent assessment by a visiting UK centre. The use of the 'Krieger' dosimetry phantom has also been evaluated. Users of the BEBIG HDR system should take care to avoid any significant bend in the transfer tube, as this will lead to positioning errors of the source, of up to 1.0 mm for slight bends, 2.0 mm for moderate bends and 5.0 mm for extreme curvature (depending on applicators and transfer tube used) for the situations reported in this study. The reason for these errors and the potential clinical impact are discussed. Users should also note the methodology employed by the system for correction of transit doses, and that no correction is made for the initial and final transit doses. The results of this investigation found that the uncorrected transit doses lead to small errors in the delivered dose at the first dwell position, of up to 2.5 cGy at 2 cm (5.6 cGy at 1 cm) from a 10 Ci source, but the transit dose correction for other dwells was accurate within 0.2 cGy. The unit has been mechanically reliable, and source positioning accuracy and dwell timing have been reproducible, with overall performance similar to other existing HDR equipment. The unit is capable of high

  4. Implementation of a High-Dose-Rate Brachytherapy Program for Carcinoma of the Cervix in Senegal: A Pragmatic Model for the Developing World

    International Nuclear Information System (INIS)

    Einck, John P.; Hudson, Alana; Shulman, Adam C.; Yashar, Catheryn M.; Dieng, Mamadou M.; Diagne, Magatte; Gueye, Latifatou; Gningue, Fama; Gaye, Pape M.; Fisher, Brandon J.; Mundt, Arno J.; Brown, Derek W.

    2014-01-01

    West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single 60 Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries

  5. Implementation of a High-Dose-Rate Brachytherapy Program for Carcinoma of the Cervix in Senegal: A Pragmatic Model for the Developing World

    Energy Technology Data Exchange (ETDEWEB)

    Einck, John P., E-mail: jeinck@ucsd.edu [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Hudson, Alana [Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada); Shulman, Adam C. [Overlook Medical Center, Summit, New Jersey (United States); Yashar, Catheryn M. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Dieng, Mamadou M.; Diagne, Magatte; Gueye, Latifatou; Gningue, Fama; Gaye, Pape M. [Départemént de Radiothérapie, Institut Joliot-Curie, Hôpital Aristide Le Dantec, Dakar (Senegal); Fisher, Brandon J. [GammaWest Cancer Services, Salt Lake City, Utah (United States); Mundt, Arno J. [Department of Radiation Medicine and Applied Sciences, University of California San Diego, San Diego, California (United States); Brown, Derek W. [Department of Oncology, Tom Baker Cancer Centre, University of Calgary, Calgary, Alberta (Canada)

    2014-07-01

    West Africa has one of the highest incidence rates of carcinoma of the cervix in the world. The vast majority of women do not have access to screening or disease treatment, leading to presentation at advanced stages and to high mortality rates. Compounding this problem is the lack of radiation treatment facilities in Senegal and many other parts of the African continent. Senegal, a country of 13 million people, had a single {sup 60}Co teletherapy unit before our involvement and no brachytherapy capabilities. Radiating Hope, a nonprofit organization whose mission is to provide radiation therapy equipment to countries in the developing world, provided a high-dose-rate afterloading unit to the cancer center for curative cervical cancer treatment. Here we describe the implementation of high-dose-rate brachytherapy in Senegal requiring a nonstandard fractionation schedule and a novel treatment planning approach as a possible blueprint to providing this technology to other developing countries.

  6. The American College of Radiology and the American Brachytherapy Society practice parameter for the performance of radionuclide-based high-dose-rate brachytherapy.

    Science.gov (United States)

    Erickson, Beth A; Bittner, Nathan H J; Chadha, Manjeet; Mourtada, Firas; Demanes, D Jeffrey

    Brachytherapy is a radiation therapy method in which radionuclide sources are used to deliver a radiation dose at a distance of up to a few centimeters by surface, intracavitary, intraluminal, or interstitial application. This practice parameter refers only to the use of radionuclides for brachytherapy. Brachytherapy alone or combined with external beam therapy plays an important role in the management and treatment of patients with cancer. High-dose-rate (HDR) brachytherapy uses radionuclides such as iridium-192 at dose rates of 20 cGy per minute (12 Gy per hour) or more to a designated target point or volume. High-dose-rate (HDR) brachytherapy is indicated for treating malignant or benign tumors where the treatment volume or targeted points are defined and accessible. Copyright © 2016 American Brachytherapy Society and American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Implementation of three-dimensional planning in brachytherapy of high dose rate for gynecology therapies

    International Nuclear Information System (INIS)

    Sales, Camila Pessoa de

    2015-01-01

    This work aims to implement the three-dimensional (3D) planning for gynecological brachytherapy treatments. For this purpose, tests of acceptance and commissioning of brachytherapy equipment were performed to establish a quality and periodic assurance program. For this purpose, an important step was searching for a material to be used as a dummy source, since the applicators do not have any specific dummy. In addition, the validation of the use of applicators library was made for reconstruction in computed tomography (CT) and magnetic resonance imaging (MRI). In order to validate 3D planning, comparison of doses in dose assessment points used in bidimensional (2D) plans have been performed with volumetric doses to adjacent organs to the tumor. Finally, a protocol was established for 3D brachytherapy planning alternately using magnetic resonance image (MRI) and CT images, making evaluation of the dose in the tumor through the recording of MR and CT images. It was not possible to find a suitable material that could be used as dummy in MRI. However, the acquisition of the license's library for the applicators made possible the 3D planning based on MRI. No correlation was found between volumetric and specific doses analyzed, showing the importance of the implementation of 3D planning. The average ratio between D 2cc and ICRU Bladder dose was 1,74, 22% higher than the ratio found by others authors. For the rectum, D 2cc was less than dose point for 60% of fractions; the average difference was 12,5%. The average ratio between D 2cc and point dose rectum, 0,85, is equivalent to the value showed by Kim et al, 0,91. The D 2cc for sigmoid was 69% higher than point dose used, unless it was not possible compare this value, since the sigmoid point used in the 2D procedures is not used in others institutes. Relative dose in 2 cc of sigmoid was 57% of the prescription dose, the same value was found by in literature. This work enabled the implementation of a viable

  8. Computed Tomography–Planned High-Dose-Rate Brachytherapy for Treating Uterine Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zolciak-Siwinska, Agnieszka, E-mail: agnieszka.zolciak@wp.pl [Department of Brachytherapy, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Gruszczynska, Ewelina; Bijok, Michal [Department of Medical Physics, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Jonska-Gmyrek, Joanna [Department of Teleradiotherapy, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Dabkowski, Mateusz [Department of Brachytherapy, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Staniaszek, Jagna [Department of Teleradiotherapy, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Michalski, Wojciech [Department of Clinical Trials and Biostatistics, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland); Kowalczyk, Adam; Milanowska, Katarzyna [Department of Medical Physics, The Maria Skłodowska-Curie Memorial Cancer Center and Institute of Oncology, Warsaw (Poland)

    2016-09-01

    Purpose: To evaluate the long-term results of computed tomography (CT)–planned high-dose-rate (HDR) brachytherapy (BT) for treating cervical cancer patients. Methods and Materials: CT-planned HDR BT was performed according to the adapted Group European de Curietherapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) recommendations in 216 consecutive patients with locally advanced cervical cancer, International Federation of Gynecology and Obstetrics (FIGO) stage IB to IVA, who were treated with conformal external beam radiation therapy and concomitant chemotherapy. We analyzed outcomes and late side effects evaluated according to the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer and Subjective, Objective, Management, Analysis evaluation scoring system and compared them with the results from a historical group. Results: The median age was 56 years (range, 32-83 years). The median follow-up time for living patients was 52 months (range 37-63 months). The 5-year cumulative incidence function for the local recurrence rate for patients with FIGO II and III was 5.5% and 20%, respectively (P=.001). The 5-year rates of overall survival (OS) and disease-free survival (DFS) were 66.4% and 58.5%, respectively. The relative risk of failure for OS and DFS for FIGO III in relation to FIGO II was 2.24 (P=.003) and 2.6 (P=.000) and for lymph node enlargement was 2.3 (P=.002) and 2 (P=.006), respectively. In 2 patients, rectovaginal fistula occurred, and in 1 patient, vesicovaginal fistula occurred without local progression. Comparison of late adverse effects in patients treated according to the GEC-ESTRO recommendations and in the historical group revealed a reduction in fistula formation of 59% and also a reduction in rectal grade 3 to 4 late toxicity of >59%. Conclusions: This is the largest report with mature data of CT-planned BT HDR for the treatment of cervical cancer with good local control and

  9. High-dose-rate intracavitary brachytherapy in the management of cervical and vaginal intraepithelial neoplasia

    International Nuclear Information System (INIS)

    Ogino, Ichiro; Kitamura, Tatsuo; Okajima, Hiroyuki; Matsubara, Sho

    1998-01-01

    Purpose: To assess the effectiveness of high-dose rate intracavitary brachytherapy (HDR-ICR) in patients with grade 3 cervical intraepithelial neoplasia (CIN-3) and grade 3 vaginal intraepithelial neoplasia (VAIN-3). Methods and Materials: This was a retrospective analysis in 20 patients with CIN-3 (n = 14) or VAIN-3 (n = 6), average age 61.9 years, managed with HDR-ICR at Kanagawa Cancer Center. Two patients with CIN-3 with microinvasive foci and 11 other patients with CIN-3 were treated with HDR-ICR for cervical lesions. Six patients with CIN-3 after hysterectomy received HDR-ICR for recurrent or residual VAIN-3 lesions. One patient received radiation therapy for both CIN-3 and VAIN-3 lesions. All these patients but one were postmenopausal. Results: Seventeen patients were treated with HDR-ICR alone, and three with combined external radiation therapy. The dose was calculated at Point A located 2 cm superior to the external os and 2 cm lateral to the axis of the intrauterine tube for intact uterus. For lesions of the vaginal stump, the dose was calculated at a point 1 cm superior to the vaginal apex or 1 cm beyond vaginal mucosa. In the 14 patients treated for CIN-3 lesions, the mean total dose of HDR-ICR was 26.1 Gy (range 20-30). Six patients received HDR-ICR for VAIN-3 lesions with mean dose of 23.3 Gy (range 15-30). At follow-up (mean 90.5 months; range 13-153), 14 patients were alive and 6 had died owing to nonmalignant intercurrent disease. No patient developed recurrent disease. Rectal bleeding occurred in three patients, but this symptom subsided spontaneously. Moderate and severe vaginal reactions were noted in two patients, in whom the treatment had included the entire vagina. Conclusions: HDR-ICR can be employed as the primary management strategy for postmenopausal women with CIN-3. In intraepithelial neoplasia involving the vaginal wall after hysterectomy, HDR-ICR should be considered as an alternative to total vaginectomy

  10. High-dose-rate brachytherapy in the treatment of uterine cervix cancer. Analysis of dose effectiveness and late complications

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Novaes, Paulo Eduardo Ribeiro dos Santos; Pellizzon, Antonio Cassio Assis; Maia, Maria Aparecida Conte; Fogarolli, Ricardo Cesar; Gentil, Andre Cavalcanti; Salvajoli, Joao Victor

    2001-01-01

    Purpose: This retrospective analysis aims to report results of patients with cervix cancer treated by external beam radiotherapy (EBR) and high-dose-rate (HDR) brachytherapy. Methods and Materials: From September 1992 to December 1996, 138 patients with FIGO Stages II and III and mean age of 56 years were treated. Median EBR to the whole pelvis was 45 Gy in 25 fractions. Parametrial boost was performed in 93% of patients, with a median dose of 14.4 Gy. Brachytherapy with HDR was performed during EBR or following its completion with a dose of 24 Gy in four weekly fractions of 6 Gy to point A. Median overall treatment time was of 60 days. Patient age, tumor stage, and overall treatment time were variables analyzed for survival and local control. Cumulative biologic effective dose (BED) at rectal and bladder reference points were correlated with late complications in these organs and dose of EBR at parametrium was correlated with small bowel complications. Results: Median follow-up time was 38 months. Overall survival, disease-free survival, and local control at 5 years was 53.7%, 52.7%, and 62%, respectively. By multivariate and univariate analysis, overall treatment time up to 50 days was the only statistically significant adverse variable for overall survival (p=0.003) and actuarial local control (p=0.008). The 5-year actuarial incidence of rectal, bladder, and small bowel late complications was 16%, 11%, and 14%, respectively. Patients treated with cumulative BED at rectum points above 110 Gy 3 and at bladder point above 125 Gy 3 had a higher but not statistically significant 5-year actuarial rate of complications at these organs (18% vs. 12%, p=0.49 and 17% vs. 9%, p=0.20, respectively). Patients who received parametrial doses larger than 59 Gy had a higher 5-year actuarial rate of complications in the small bowel; however, this was not statistically significant (19% vs. 10%, p=0.260). Conclusion: This series suggests that 45 Gy to the whole pelvis combined with

  11. Radioablation of liver malignancies with interstitial high-dose-rate brachytherapy. Complications and risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mohnike, Konrad; Wolf, Steffen; Damm, Robert; Seidensticker, Max; Seidensticker, Ricarda; Fischbach, Frank; Pech, Maciej; Ricke, Jens [Otto-von-Guericke-Universitaet, Klinik fuer Radiologie und Nuklearmedizin, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany); Peters, Nils; Hass, Peter; Gademann, Guenther [Otto-von-Guericke-Universitaet, Klinik fuer Strahlentherapie, Universitaetsklinikum Magdeburg A.oe.R., Magdeburg (Germany)

    2016-05-15

    To evaluate complications and identify risk factors for adverse events in patients undergoing high-dose-rate interstitial brachytherapy (iBT). Data from 192 patients treated in 343 CT- or MRI-guided interventions from 2006-2009 at our institution were analyzed. In 41 %, the largest tumor treated was ≥ 5 cm, 6 % of the patients had tumors ≥ 10 cm. Prior to iBT, 60 % of the patients had chemotherapy, 22 % liver resection, 19 % thermoablation or transarterial chemoembolization (TACE). Safety was the primary endpoint; survival data were obtained as the secondary endpoints. During follow-up, MRI or CT imaging was performed and clinical and laboratory parameters were obtained. The rate of major complications was below 5 %. Five major bleedings (1.5 %) occurred. The frequency of severe bleeding was significantly higher in patients with advanced liver cirrhosis. One patient developed signs of a nonclassic radiation-induced liver disease. In 3 patients, symptomatic gastrointestinal (GI) ulcers were detected. A dose exposure to the GI wall above 14 Gy/ml was a reliable threshold to predict ulcer formation. A combination of C-reactive protein ≥ 165 mg/l and/or leukocyte count ≥ 12.7 Gpt/l on the second day after the intervention predicted infection (sensitivity 90.0 %; specificity 92.8 %.) Two patients (0.6 %) died within 30 days. Median overall survival after the first liver treatment was 20.1 months for all patients and the local recurrence-free surviving proportion was 89 % after 12 months. Image-guided iBT yields a low rate of major complications and is effective. (orig.) [German] Evaluierung der Komplikationsrate und Identifizierung von Risikofaktoren fuer Komplikationen und Nebenwirkungen bei Patienten mit Lebermalignomen, die mit der hochdosierten interstitiellen Brachytherapie (iBT) behandelt wurden. Von 2006 bis 2009 wurden 192 Patienten in 343 CT- oder MRT-gefuehrten Interventionen behandelt und deren Daten ausgewertet. Der groesste behandelte Tumor war in

  12. Optimal bladder filling during high-dose-rate intracavitary brachytherapy for cervical cancer: a dosimetric study

    Directory of Open Access Journals (Sweden)

    Umesh Mahantshetty

    2017-04-01

    Full Text Available Purpose: The aim of this study is to compare 3D dose volume histogram (DVH parameters of bladder and other organs at risk with different bladder filling protocol during high-dose-rate intracavitary brachytherapy (HDR-ICBT in cervical cancer, and to find optimized bladder volume. Material and methods : This dosimetric study was completed with 21 patients who underwent HDR-ICBT with computed tomography/magnetic resonance compatible applicator as a routine treatment. Computed tomography planning was done for each patient with bladder emptied (series 1, after 50 ml (series 2, and 100 ml (series 3 bladder filling with a saline infusion through the bladder catheter. Contouring was done on the Eclipse Planning System. 7 Gy to point A was prescribed with the standard loading patterns. Various 3D DVH parameters including 0.1 cc, 1 cc, 2 cc doses and mean doses to the OAR’s were noted. Paired t-test was performed. Results : The mean (± SD bladder volume was 64.5 (± 25 cc, 116.2 (± 28 cc, and 172.9 (± 29 cc, for series 1, 2, and 3, respectively. The 0.1 cm 3 ,1 cm 3 , 2 cm 3 mean bladder doses for series 1, series 2, and series 3 were 9.28 ± 2.27 Gy, 7.38 ± 1.72 Gy, 6.58 ± 1.58 Gy; 9.39 ± 2.28 Gy, 7.85 ± 1.85 Gy, 7.05 ± 1.59 Gy, and 10.09 ± 2.46 Gy, 8.33 ± 1.75 Gy, 7.6 ± 1.55 Gy, respectively. However, there was a trend towards higher bladder doses in series 3. Similarly, for small bowel dose 0.1 cm 3 , 1 cm 3 , and 2 cm 3 in series 1, 2, and 3 were 5.44 ± 2.2 Gy, 4.41 ± 1.84 Gy, 4 ± 1.69 Gy; 4.57 ± 2.89 Gy, 3.78 ± 2.21 Gy, 3.35 ± 2.02 Gy, and 4.09 ± 2.38 Gy, 3.26 ± 1.8 Gy, 3.05 ± 1.58 Gy. Significant increase in small bowel dose in empty bladder (series 1 compared to full bladder (series 3 (p = 0.03 was noted. However, the rectal and sigmoid doses were not significantly affected with either series. Conclusions : Bladder filling protocol with 50 ml and 100 ml was well tolerated and achieved a reasonably reproducible bladder volume

  13. Treatment of skin carcinomas of the face by high-dose-rate brachytherapy and custom-made surface molds

    International Nuclear Information System (INIS)

    Guix, Benjamin; Finestres, Fernando; Tello, Jose-Ignacio; Palma, Cesar; Martinez, Antonio; Guix, Jose-Ramon; Guix, Ricardo

    2000-01-01

    Purpose: To analyze the results obtained in a prospective group of patients with basal or squamous cell skin carcinomas of the face treated by high-dose-rate (HDR) brachytherapy via custom-made surface molds. Methods and Materials: A total of 136 patients with basal or squamous cell carcinomas of the face were treated between March 1992 and March 1997 by surface molds and HDR brachytherapy with iridium-192. Nineteen patients were treated with standard Brock applicators and 117 patients with custom-made polymethyl methacrylate applicators, built over a plaster mold obtained of the patient's face. Minimum dose administered to the tumor was 6000 to 6500 cGy in 33 to 36 fractions at 180 cGy/fraction in lesions of up to 4 cm. Lesions greater than 4 cm were boosted up to 7500-8000 cGy after a 3-week pause. Results: With the custom-made surface molds, the dose distribution was uniform in the surface of the skin and at 5 mm depth in the whole area of the applicator. Differences between the areas of maximum and minimum dose at this depth never reached values higher than 5% of the prescribed dose. At the edges of the custom-made molds dose gradient was sharp, with the detected dose at 5 mm from the applicator being negligible. All the patients were complete responders. There were 3 local recurrences, 1/73 patients treated for primary tumor and 2/63 patients treated for recurrent tumor. Actuarial local control at 5 years for all patients was 98%, for those patients with primary tumors 99%, and for recurrent patients 87%. The treatment tolerance was excellent in all cases. No severe, early, or late, complications were detected. Conclusions: Radiotherapy is a highly effective treatment of skin carcinomas of the face. Custom-made molds, to be used in conjunction with HDR brachytherapy equipment, make possible a uniform dose distribution, with a sharp dose gradient in the limits of applicators. Custom-made surface molds are easy and safe to use, and they fit very accurately for

  14. Sci-Thur PM – Brachytherapy 06: 3D Printed Surface Applicators for High Dose Rate Brachytherapy

    International Nuclear Information System (INIS)

    Clarke, Scott; Yewondwossen, Mammo; Robar, James

    2016-01-01

    Purpose: The purpose of this work is to develop a new applicator for administering high dose rate (HDR) brachytherapy using 3D printing technology. Primary advantages of using a 3D printed applicator will be to offer a more streamlined approach for therapists and patients while achieving better conformity, reproducibility, and patient specific applicators. Methods: A phantom study was conducted to measure the effectiveness of a 3D printed surface applicator by analyzing tumours on three locations of the body: the foot, nose, and scalp. The applicator was designed using Eclipse and further modified using Blender to create the catheter tunnels before being printed on a Lulzbot Taz 5 3D printer. A radiation plan was made using Oncentra Brachytherapy for a control treatment option using Freiburg Flaps and one with the novel method of a 3D printed applicator. A comparative analysis was made using D90, D100, V100, V150, and V200 Results: The 3D printed applicator showed comparable dose coverage with significant improvements on highly irregular surfaces when analyzed against a plan made using Freiburg Flaps. Although both plans exhibited complete tumour coverage, the 3D applicator showed improvements in D90 and V150 and the 3D applicator had a dose homogeneity index (DHI) of 0.99 compared to a DHI of 0.97 for the control. Therapist prep time also dropped significantly due to the lack of need for a thermoplastic mesh. Conclusions: 3D printed applicators for treatment of superficial sites proved to offer more patient convenience, less prep time, better conformity and tighter margins.

  15. A generalized linear-quadratic model for radiosurgery, stereotactic body radiation therapy, and high-dose rate brachytherapy.

    Science.gov (United States)

    Wang, Jian Z; Huang, Zhibin; Lo, Simon S; Yuh, William T C; Mayr, Nina A

    2010-07-07

    Conventional radiation therapy for cancer usually consists of multiple treatments (called fractions) with low doses of radiation. These dose schemes are planned with the guidance of the linear-quadratic (LQ) model, which has been the most prevalent model for designing dose schemes in radiation therapy. The high-dose fractions used in newer advanced radiosurgery, stereotactic radiation therapy, and high-dose rate brachytherapy techniques, however, cannot be accurately calculated with the traditional LQ model. To address this problem, we developed a generalized LQ (gLQ) model that encompasses the entire range of possible dose delivery patterns and derived formulas for special radiotherapy schemes. We show that the gLQ model can naturally derive the traditional LQ model for low-dose and low-dose rate irradiation and the target model for high-dose irradiation as two special cases of gLQ. LQ and gLQ models were compared with published data obtained in vitro from Chinese hamster ovary cells across a wide dose range [0 to approximately 11.5 gray (Gy)] and from animals with dose fractions up to 13.5 Gy. The gLQ model provided consistent interpretation across the full dose range, whereas the LQ model generated parameters that depended on dose range, fitted only data with doses of 3.25 Gy or less, and failed to predict high-dose responses. Therefore, the gLQ model is useful for analyzing experimental radiation response data across wide dose ranges and translating common low-dose clinical experience into high-dose radiotherapy schemes for advanced radiation treatments.

  16. Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

    Directory of Open Access Journals (Sweden)

    Seyed Mohsen Hosseini Daghigh

    2012-03-01

    Full Text Available Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phantom was built in order to be inserted by various sizes of esophageal applicators. EDR2 films were placed at 33 mm from Ir-192 source and irradiated with 1.5 Gy after planning using treatment planning system for all applicators. Results The results of film dosimetry in reference point for 6, 8, 10, and 20 mm applicators were 1.54, 1.53, 1.48, and 1.50 Gy, respectively. The difference between practical and treatment planning system results was 0.023 Gy (

  17. Advantages of high-dose rate (HDR) brachytherapy in treatment of prostate cancer

    Science.gov (United States)

    Molokov, A. A.; Vanina, E. A.; Tseluyko, S. S.

    2017-09-01

    One of the modern methods of preserving organs radiation treatment is brachytherapy. This article analyzes the results of prostate brachytherapy. These studies of the advantages of high dose brachytherapy lead to the conclusion that this method of radiation treatment for prostate cancer has a favorable advantage in comparison with remote sensing methods, and is competitive, preserving organs in comparison to surgical methods of treatment. The use of the method of polyfocal transperineal biopsy during the brachytherapy session provides information on the volumetric spread of prostate cancer and adjust the dosimetry plan taking into account the obtained data.

  18. Five Years' Experience Treating Locally Advanced Cervical Cancer With Concurrent Chemoradiotherapy and High-Dose-Rate Brachytherapy: Results From a Single Institution

    International Nuclear Information System (INIS)

    Parker, Kate; Gallop-Evans, Eve; Hanna, Louise; Adams, Malcolm

    2009-01-01

    Purpose: To assess the clinical outcomes after concurrent cisplatin chemotherapy and radiotherapy (RT) followed by high-dose-rate brachytherapy for locally advanced carcinoma of the cervix and perform a multivariate analysis of the prognostic factors. Methods and Materials: The outcomes were analyzed for all women treated between 1999 and 2004 with concurrent cisplatin chemotherapy and RT followed by high-dose-rate brachytherapy. Kaplan-Meier analysis was used for overall survival (OS), local control (LC), and distant control (DC). The Cox proportional hazards model was used to perform multivariate analysis of the prognostic variables. Results: The standard regimen comprised whole pelvic external RT 45 Gy in 25 fractions with concurrent weekly cisplatin 40 mg/m 2 , followed by four high-dose-rate brachytherapy insertions of 6 Gy. Patients with radiologically enlarged para-aortic lymph nodes underwent extended-field RT. Of 92 patients, the OS rate was 72% at 2 years and 55% at 5 years. The LC rate was 76% at 2 years and 67% at 5 years. The DC rate was 68% at 2 years and 48% at 5 years. The most important prognostic factor for OS, LC, and DC was the pretreatment hemoglobin. For OS, the tumor size and the presence of enlarged lymph nodes were also important. For LC, the number of brachytherapy insertions was important; and for DC, the number of chemotherapy treatments was important. Of the patients, 4% experienced late Grade 3 or 4 toxicity. Conclusion: The results of our study have shown that the regimen is effective, with acceptable long-term side effects. In this cohort, the most important prognostic factor was the pretreatment hemoglobin level, a disease-related factor. However, more effective systemic treatments are needed.

  19. External beam radiation and high-dose-rate brachytherapy for elderly patients with gastroesophageal junction adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Wei Zhang

    2017-07-01

    Full Text Available Purpose: The aim of this study was to retrospectively observe and analyze the long-term treatment outcomes of 96 elderly patients with gastroesophageal junction adenocarcinoma (GEJAC who were treated with californium-252 (252Cf neutron brachytherapy (NBT in combination with external beam radiotherapy (EBRT with or without chemotherapy. Material and methods: From January 2002 to November 2012, 96 patients with GEJAC underwent treatment. The total radiation dose to the reference point via NBT was 8-25 Gy-eq in 2 to 5 fractions, with 1 fraction per week. The total dose via EBRT was 40-54 Gy, which was delivered over a period of 4 to 5.5 weeks with normal fraction. Results: The median survival time for the 96 patients was 15.3 months, and the 1-, 2-, 3-, and 5-year rates of overall survival (OS were 62.5%, 33.7%, 20.1%, and 7.9%, respectively. The 1-, 2-, 3-, and 5-year rates for local-regional control (LRC were 78.7%, 57.9%, 41.8%, and 26.4%, respectively. The patients’ age was an independent factor that was significantly associated with OS (p = 0.006 and LRC (p = 0.0005, according to univariate analysis. The 3-year OS (LRC was 31.9% (62.9% for patients aged 70-74 years and 16.1% (19.5% for patients aged ≥ 75 years. From the time of treatment completion to the development of local-regional recurrence or death, 5 (5.2% patients experienced fistula and 7 (7.3% experienced massive bleeding. Conclusions: The clinical data indicated that NBT in combination with EBRT produced favorable local control and long-term survival rates for elderly patients with GEJAC, and that the side effects were tolerable. The patient’s age could be used to select the appropriate treatment in an elderly patient.

  20. Conventional external beam radiation therapy and high dose rate afterloading brachytherapy as a boost for patients older than 70 years

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Salvajoli, Joao Vitor; Fogaroli, Ricardo Cesar; Novaes, Paulo Eduardo R.S.; Maia, Maria Aparecida Conte; Ferrigno, Robson

    2005-01-01

    The treatment options for patients with non metastatic prostate cancer range from observation, radical prostatectomy, radiation therapy, hormonal therapy to various combination of some to all of them. Objective: we evaluated the impact on biochemical control of disease (bNED), acute and late intestinal (GI) and urological (GU) morbidity for a group of patients older than 70 years presenting initial or locally advanced prostate cancer treated with fractionated high dose rate brachytherapy (HDRB) as a boost to conventional external beam radiation therapy (RT) at the Department of Radiation Oncology from Hospital do Cancer A. C. Camargo, Sao Paulo, Brazil. Methods: a total of 56 patients older than 70 were treated from March, 1997 to June, 2002. All patients had prior to HDRB a course of RT to a median dose of 45 Gy. HDRB doses ranged from 16 Gy to 20 Gy, given in 4 fractions. Results: the median age of the patients was 74.4 years (range 70-83) and the median follow-up 33 months (range 24 to 60). The 5-year actuarial bNED rate was 77%. Acute GU and GI morbidity G1-2 were seen in 17.8% and 7.1% of patients, respectively. Late G1 or G2 GU morbidity was seen in 10.7% of the patients, while late G3 morbidity was observed in 7.1% of the patients, represented by urethral strictures. Conclusion: this group of patients had similar bNED rates when compared to literature, with acceptable morbidity rates. (author)

  1. Automated construction of an intraoperative high-dose-rate treatment plan library for the Varian brachytherapy treatment planning system.

    Science.gov (United States)

    Deufel, Christopher L; Furutani, Keith M; Dahl, Robert A; Haddock, Michael G

    2016-01-01

    The ability to create treatment plans for intraoperative high-dose-rate (IOHDR) brachytherapy is limited by lack of imaging and time constraints. An automated method for creation of a library of high-dose-rate brachytherapy plans that can be used with standard planar applicators in the intraoperative setting is highly desirable. Nonnegative least squares algebraic methods were used to identify dwell time values for flat, rectangular planar applicators. The planar applicators ranged in length and width from 2 cm to 25 cm. Plans were optimized to deliver an absorbed dose of 10 Gy to three different depths from the patient surface: 0 cm, 0.5 cm, and 1.0 cm. Software was written to calculate the optimized dwell times and insert dwell times and positions into a .XML plan template that can be imported into the Varian brachytherapy treatment planning system. The user may import the .XML template into the treatment planning system in the intraoperative setting to match the patient applicator size and prescribed treatment depth. A total of 1587 library plans were created for IOHDR brachytherapy. Median plan generation time was approximately 1 minute per plan. Plan dose was typically 100% ± 1% (mean, standard deviation) of the prescribed dose over the entire length and width of the applicator. Plan uniformity was best for prescription depths of 0 cm and 0.5 cm from the patient surface. An IOHDR plan library may be created using automated methods. Thousands of plan templates may be optimized and prepared in a few hours to accommodate different applicator sizes and treatment depths and reduce treatment planning time. The automated method also enforces dwell time symmetry for symmetrical applicator geometries, which simplifies quality assurance. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  2. Clinical result of high-dose rate intraluminal brachytherapy for esophageal carcinoma with a remote afterloading system

    International Nuclear Information System (INIS)

    Fukuda, Haruyuki; Nakajima, Toshifumi; Tada, Takuhito; Tanaka, Masahiro; Tsumura, Masashi; Onoyama, Yasuto

    1992-01-01

    During the period from 1977 through 1987, 105 patients with esophageal carcinoma were radically treated by radiotherapy. Forty-six patients receiving therapy before August 1982 were all treated by external beam therapy alone (Group 1). Since September 1982, 26 patients were treated by external beam therapy alone (Group 2) and 33 patients were treated by high-dose-rate intraluminal brachytherapy with a remote afterloading system combined with external beam therapy (Group 3). Dose of external beam therapy for Group 1, Group 2 and Group 3 patients were 66.7 Gy, 68.7 Gy and 55.9 Gy on the average. The intraluminal brachytherapy was performed with a total dose of 12 Gy consisting of 3 Gy twice a week. Ten of 72 patients (14%) treated by external beam therapy alone achieved complete response, whereas 14 of 33 patients (42%) treated by high-dose-rate intraluminal brachytherapy combined with external beam therapy had complete response. One-, and 3-year survival rates were 36% and 10% in the Group 1, 32% and 12% in the Group 2 and 56% and 36% in the Group 3. For Group 3, good survival rate was obtained in tumorous type and serrated type. Patients with tumor of less than 5 cm in Group 3 had good survival. The data suggest that the high-dose-rate intraluminal bracytherapy prescribed as a boost therapy following external beam therapy is an effective therapy modality for esophageal carcinoma which is of non-circumferential tumor or less than 5 cm. (author)

  3. Evaluation of failure modes of computerized planning phase of interstitial implants with high dose rate brachytherapy using HFMEA

    International Nuclear Information System (INIS)

    Biazotto, Bruna; Tokarski, Marcio

    2014-01-01

    This paper evaluates the failure modes of the computerized planning step in interstitial implants with high dose rate brachytherapy. The prospective tool of risk management Health Care Failure Mode and Effects Analysis (HFMEA) was used. Twelve subprocesses were identified, and 33 failure modes of which 21 justified new safety actions, and 9 of them were intolerable risks. The method proved itself useful in identifying failure modes, but laborious and subjective in their assessment. The main risks were due to human factors, which require training and commitment of management to their mitigation. (author)

  4. Late toxicity and five year outcomes after high-dose-rate brachytherapy as a monotherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Ghadjar, Pirus; Oesch, Sebastian L; Rentsch, Cyrill A; Isaak, Bernhard; Cihoric, Nikola; Manser, Peter; Thalmann, George N; Aebersold, Daniel M

    2014-01-01

    To determine the 5-year outcome after high-dose-rate brachytherapy (HDR-BT) as a monotherapy. Between 10/2003 and 06/2006, 36 patients with low (28) and intermediate (8) risk prostate cancer were treated by HDR-BT monotherapy. All patients received one implant and 4 fractions of 9.5 Gy within 48 hours for a total prescribed dose (PD) of 38 Gy. Five patients received concomitant androgen deprivation therapy (ADT). Toxicity was scored according to the common terminology criteria for adverse events from the National Cancer Institute (CTCAE) version 3.0. Biochemical recurrence was defined according to the Phoenix criteria and analyzed using the Kaplan Meier method. Predictors for late grade 3 GU toxicity were analyzed using univariate and multivariate Cox regression analyses. The median follow-up was 6.9 years (range, 1.5-8.0 years). Late grade 2 and 3 genitourinary (GU) toxicity was observed in 10 (28%) and 7 (19%) patients, respectively. The actuarial proportion of patients with late grade 3 GU toxicity at 5 years was 17.7%. Late grade 2 and 3 gastrointestinal (GI) toxicities were not observed. The crude erectile function preservation rate in patients without ADT was 75%. The 5 year biochemical recurrence-free survival (bRFS) rate was 97%. Late grade 3 GU toxicity was associated with the urethral volume (p = 0.001) and the urethral V 120 (urethral volume receiving ≥120% of the PD; p = 0.0005) after multivariate Cox regression. After HDR-BT monotherapy late grade 3 GU was observed relatively frequently and was associated with the urethral V 120 . GI toxicity was negligible, the erectile function preservation rate and the bRFS rate was excellent

  5. Toxicity and cosmetic result of partial breast high-dose-rate interstitial brachytherapy for conservatively operated early breast cancer

    International Nuclear Information System (INIS)

    Xiu Xia; Tripuraneni Prabhakar; Giap Huan; Lin Ray; Chu Colin

    2007-01-01

    Objective: Objective To study the method, side effects and cosmetic outcome of high- dose-rate (HDR) accelerated partial breast interstitial irradiation (APBI) alone in early stage breast cancer' after conservative surgery. Methods: From February 2002 to June 2003,47 breast cancer lesions from 46 patients suffering from stage I/II breast cancer were treated with HDR 192 Ir APBI after conservative surgery. All patients were over 40 year-old, with T1-2N0-1 (≤3 lymph nodes positive), surgical margin > 1-2 mm, but those having lobular or inflammatory breast cancer were excluded. HDR brachytherapy with 34 Gy, 10 fractions/5 days was used after surgery, toxic reaction and cosmetic outcome were observed in one month, 6 and 12 months respectively. Results: Follow up of 1846 months, 34 months was carried out for the whole group. During the treatment, acute reactions including: erythema, edema, tenderness and infection, all under I-II grade, none of III-IV grade were observed in 21 patients(46%); late toxicity reactions: skin fibrosis, breast tenderness, fat necrosis, and telangiectasia, totally 20 patients (43%) were observed: 2 patients in III grade but one patient received 6 cycle chemotherapy. The result of cosmetic outcome evaluation was excellent or good, at 6 months 95% and 12 months 98%, respectively, but there was no recurfence. Conclusions: Excellent and favorable cosmetic results are noted after APBI by interstitial alone. Acute and late reactions are few. Long term observation is necessary for the rate of' local control. (authors)

  6. High dose rate versus low dose rate brachytherapy for oral cancer--a meta-analysis of clinical trials.

    Science.gov (United States)

    Liu, Zhenxing; Huang, Shengyun; Zhang, Dongsheng

    2013-01-01

    To compare the efficacy and safety of high dose rate (HDR) and low dose rate (LDR) brachytherapy in treating early-stage oral cancer. A systematic search of MEDLINE, EMBASE and Cochrane Library databases, restricted to English language up to June 1, 2012, was performed to identify potentially relevant studies. Only randomized controlled trials (RCT) and controlled trials that compared HDR to LDR brachytherapy in treatment of early-stage oral cancer (stages I, II and III) were of interest. Two investigators independently extracted data from retrieved studies and controversies were solved by discussion. Meta-analysis was performed using RevMan 5.1. One RCT and five controlled trials (607 patients: 447 for LDR and 160 for HDR) met the inclusion criteria. The odds ratio showed no statistically significant difference between LDR group and HDR group in terms of local recurrence (OR = 1.12, CI 95% 0.62-2.01), overall mortality (OR = 1.01, CI 95% 0.61-1.66) and Grade 3/4 complications (OR = 0.86, CI 95% 0.52-1.42). This meta-analysis indicated that HDR brachytherapy was a comparable alternative to LDR brachytherapy in treatment of oral cancer. HDR brachytherapy might become a routine choice for early-stage oral cancer in the future.

  7. Prediction of late rectal complication following high-dose-rate intracavitary brachytherapy in cancer of the uterine cervix

    International Nuclear Information System (INIS)

    Lee, Jeung Eun; Huh, Seung Jae; Park, Won; Lim, Do Hoon; Ahn, Yong Chan

    2003-01-01

    Although high-dose-rate intracavitary radiotherapy (HDR ICR) has been used in the treatment of cervical cancer, the potential for increased risk of late complication, most commonly in the rectum, is a major concern. We have previously reported on 136 patients treated with HDR brachytherapy between 1995 and 1999. The purpose of this study is to upgrade the previous data and confirm the correlation between late rectal complication and rectal dose in cervix cancer patients treated with HDR ICR. A retrospective analysis was performed for 222 patients with cervix cancer who were treated for curative intent with extemal beam radiotherapy (EBRT) and HDR ICR from July 1995 to December 2001. The median dose of EBRT was 50.4 (30.6-56.4) Gy with a daily fraction size 1.8 Gy. A total of six fractions of HDR ICR were given twice weekly with fraction size of 4 (3-5.5) Gy to A point by Iridium-192 source. The rectal dose was calculated at the rectal reference point using the barium contrast criteria in vivo measurement of the rectal dose was performed with thermoluminescent dosimeter (TLD) during HDR ICR. The median follow-up period was 39 months, ranging from 6 to 90 months. Twenty-one patients (9.5%) experienced late rectal bleeding, from 3 to 44 months (median, 13 months) after the completion of RT. The calculated rectal doses were not different between the patients with rectal bleeding and those without, but the measured rectal doses were higher in the complicated patients. The differences of the measured ICR rectal fractional dose, ICR total rectal dose, and total rectal biologically equivalent dose (BED) were statistically significant. When the measured ICR total rectal dose was beyond 16 Gy, when the ratio of the measured rectal dose to A point dose was beyond 70%, or when the measured rectal BED was over 110 GY 3 , a high possibility of late rectal complication was found. Late rectal complication was closely correlated with measured rectal dose by in vivo dosimetry using

  8. Outcomes Associated With 3 Treatment Schedules of High-Dose-Rate Brachytherapy Monotherapy for Favorable-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jawad, Maha Saada; Dilworth, Joshua T.; Gustafson, Gary S.; Ye, Hong; Wallace, Michelle [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Martinez, Alvaro [Michigan HealthCare Professionals/21" s" t Century Oncology, Farmington Hills, Michigan (United States); Chen, Peter Y. [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States); Krauss, Daniel J., E-mail: DKrauss@beaumont.edu [Department of Radiation Oncology, Oakland University William Beaumont School of Medicine, Royal Oak, Michigan (United States)

    2016-03-15

    Purpose: We report the outcomes associated with 3 high-dose-rate (HDR) brachytherapy regimens used as monotherapy for favorable-risk prostate cancer. Methods and Materials: Four hundred ninety-four patients with stage ≤T2b prostate cancer, Gleason score ≤7, and prostate-specific antigen levels ≤15 ng/mL underwent HDR brachytherapy as monotherapy. Of those, 319 received 38 Gy in 4 fractions, 79 received 24 Gy in 2 fractions, and 96 received 27 Gy in 2 fractions. Acute and chronic genitourinary (GU) and gastrointestinal (GI) toxicities were defined as side effects occurring ≤6 and >6 months, respectively, after radiation therapy (RT) and were graded according to the Common Terminology Criteria for Adverse Events version 3.0. The time to toxicity was calculated from the date of RT completion. Variables were analyzed with χ{sup 2} test. P values <.05 were considered significant. Results: The median overall follow-up time was 4 years (range, 5.5, 3.5, and 2.5 years for 38 Gy, 24 Gy, and 27 Gy, respectively, P<.001). Acute and chronic grade ≥2 GU and GI toxicity profiles were similar among groups. Acceptable rates of grade 2 GU toxicities were seen with overall acute/chronic frequency/urgency, dysuria, retention, incontinence, and hematuria rates of 14%/20%, 6%/7%, 7%/4%, 1.5%/2%, and 1.5%/7%, respectively. Minimal grade 3 and no grade 4 or 5 toxicities were seen. Grade 1, 2, and 3 chronic urethral stricture rates were 0.3%, 2%, and 1%, respectively. All GI toxicities were similar between groups, with overall rates of acute/chronic grade 2 diarrhea, rectal pain/tenesmus, rectal bleeding, and proctitis of 1%/1%, <1%/0.5%, 0%/2%, and <1%/1%, respectively. No grade 3, 4, or 5 toxicities were seen. All comparisons were similar for hormone-naïve patients. The median time to maximal GU/GI toxicity was similar between groups, ranging from 1 to 1.6 to 0.9 to 1.2 years, respectively. There were no differences in clinical outcomes between the 3 groups at 5

  9. Real-time inverse high-dose-rate brachytherapy planning with catheter optimization by compressed sensing-inspired optimization strategies.

    Science.gov (United States)

    Guthier, C V; Aschenbrenner, K P; Müller, R; Polster, L; Cormack, R A; Hesser, J W

    2016-08-21

    This paper demonstrates that optimization strategies derived from the field of compressed sensing (CS) improve computational performance in inverse treatment planning (ITP) for high-dose-rate (HDR) brachytherapy. Following an approach applied to low-dose-rate brachytherapy, we developed a reformulation of the ITP problem with the same mathematical structure as standard CS problems. Two greedy methods, derived from hard thresholding and subspace pursuit are presented and their performance is compared to state-of-the-art ITP solvers. Applied to clinical prostate brachytherapy plans speed-up by a factor of 56-350 compared to state-of-the-art methods. Based on a Wilcoxon signed rank-test the novel method statistically significantly decreases the final objective function value (p  optimization times were below one second and thus planing can be considered as real-time capable. The novel CS inspired strategy enables real-time ITP for HDR brachytherapy including catheter optimization. The generated plans are either clinically equivalent or show a better performance with respect to dosimetric measures.

  10. Preliminary results of concurrent chemotherapy and radiation therapy using high-dose-rate brachytherapy for cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Ja; Lee, Ji Hye; Lee, Re Na; Suh, Hyun Suk [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2006-09-15

    To determine the efficacy and safety of concurrent chemotherapy and radiation therapy with high-dose-rate brachytherapy for cervical cancer. From January 2001 to December 2002, 30 patients with cervical cancer were treated with concurrent chemotherapy (cisplatin and 5-FU) and definitive radiation therapy. The median age was 58 (range 34 {approx} 74) year old. The pathology of the biopsy sections was squamous cell carcinoma in 29 patients and one was adenocarcinoma. The distribution to FIGO staging system was as follow: stage IB, 7 (23%); IIA, 3 (10%); IIB, 12 (40%); IIIA, 3 (10%); IIIB, 5 (17%). All patients received pelvic external beam irradiation (EBRT) to a total dose of 45 {approx} 50.4 Gy (median: 50.4 Gy) over 5 {approx} 5.5 weeks. Ir-192 HDR intracavity brachytherapy (ICBT) was given after a total dose of 41.1 Gy. HDR-ICBT was performed twice a week, with a fraction point. A dose of 4 Gy and median dose to point A was 28 Gy (range: 16 {approx} 32 Gy) in 7 fractions. The median cumulative biologic effective dose (BED) at point A (EBRT + ICBT) was 88 Gy{sub 10} (range:77 {approx} 94 Gy{sub 10}). The median cumulative BED at ICRU 38 reference point (EBRT + ICBT) was 131 Gy{sub 3} (range: 122 {approx} 140 Gy{sub 3}) at point A, 109 Gy{sub 3} (range:88{approx} 125 Gy{sub 3}) at the rectum and 111 Gy{sub 3} (range: 91 {approx} 123 Gy{sub 3}) at the urinary bladder. Cisplatin (60 mg/m{sup 2}) and 5-FU (1,000 mg/m{sup 2}) was administered intravenously at 2 weeks interval from the first day of radiation for median 5 (range:2 {approx} 6) cycles. The assessment was performed at 1 month after completion of radiation therapy by clinical examination and CT scan. The median follow-up time was 36 months (range:8{approx} 50 months). The complete response rate after concurrent chemo radiation therapy was 93.3%. The 3-yr actuarial pelvic control rate was 87% and 3-yr actuarial overall survival and disease-free survival rate was 93% and 87%, respectively. The local failure

  11. Modelling second malignancy risks from low dose rate and high dose rate brachytherapy as monotherapy for localised prostate cancer.

    Science.gov (United States)

    Murray, Louise; Mason, Joshua; Henry, Ann M; Hoskin, Peter; Siebert, Frank-Andre; Venselaar, Jack; Bownes, Peter

    2016-08-01

    To estimate the risks of radiation-induced rectal and bladder cancers following low dose rate (LDR) and high dose rate (HDR) brachytherapy as monotherapy for localised prostate cancer and compare to external beam radiotherapy techniques. LDR and HDR brachytherapy monotherapy plans were generated for three prostate CT datasets. Second cancer risks were assessed using Schneider's concept of organ equivalent dose. LDR risks were assessed according to a mechanistic model and a bell-shaped model. HDR risks were assessed according to a bell-shaped model. Relative risks and excess absolute risks were estimated and compared to external beam techniques. Excess absolute risks of second rectal or bladder cancer were low for both LDR (irrespective of the model used for calculation) and HDR techniques. Average excess absolute risks of rectal cancer for LDR brachytherapy according to the mechanistic model were 0.71 per 10,000 person-years (PY) and 0.84 per 10,000 PY respectively, and according to the bell-shaped model, were 0.47 and 0.78 per 10,000 PY respectively. For HDR, the average excess absolute risks for second rectal and bladder cancers were 0.74 and 1.62 per 10,000 PY respectively. The absolute differences between techniques were very low and clinically irrelevant. Compared to external beam prostate radiotherapy techniques, LDR and HDR brachytherapy resulted in the lowest risks of second rectal and bladder cancer. This study shows both LDR and HDR brachytherapy monotherapy result in low estimated risks of radiation-induced rectal and bladder cancer. LDR resulted in lower bladder cancer risks than HDR, and lower or similar risks of rectal cancer. In absolute terms these differences between techniques were very small. Compared to external beam techniques, second rectal and bladder cancer risks were lowest for brachytherapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Non-melanoma skin cancer treated with high-dose-rate brachytherapy: a review of literature

    OpenAIRE

    Durim Delishaj; Agata Rembielak; Bruno Manfredi; Stefano Ursino; Francesco Pasqualetti; Concetta Laliscia; Francesca Orlandi; Riccardo Morganti; Maria Grazia Fabrini; Fabiola Paiar

    2016-01-01

    Purpose: The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT) might be a better therapeutic option due to high radiation dose concentration to the tumor with rapid dose fall-off resulting in normal tissues sparing. The aim of this review was to evaluate...

  13. Complete response of endemic Kaposi sarcoma lesions with high-dose-rate brachytherapy: treatment method, results, and toxicity using skin surface applicators.

    Science.gov (United States)

    Kasper, Michael E; Richter, Sam; Warren, Nicholas; Benda, Rashmi; Shang, Charles; Ouhib, Zoubir

    2013-01-01

    To analyze the clinical outcome of Kaposi sarcoma skin lesions treated with high-dose-rate (HDR) brachytherapy in patients with a minimum of 2 years of followup. Between February 2006 and July 2008, all patients with Kaposi sarcoma who received (192)Ir HDR brachytherapy using a skin surface applicator were evaluated for clinical response. Responses to treatment and toxicity were scored using standard criteria. Sixteen cases were collected. Treatment was delivered in four to six fractions, over a period of approximately 12 days. The specified dose ranged from 24 to 35Gy. Median followup the lesion was 41.4 months. No lesion was greater than 2cm. All patients had a complete response to treatment, with no evidence of local recurrence or tumor progression. Thirteen lesions developed Grade 1 and two lesions had Grade 2 acute skin reactions. One patient developed late skin changes with telangiectasias and hypopigmentation. HDR brachytherapy treatment seems to be an effective noninvasive option for patients with small cutaneous Kaposi sarcoma lesions, delivering excellent cosmesis and local control in our small series. Fewer fractions over a shorter period used in our group offer patients more convenience compared with other common regimens. Although HDR is being used more frequently for many surface applications, additional clinical studies with larger numbers of patients and longer followup are needed to confirm the general impression that it is an excellent option for many patients. Copyright © 2013 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. After low and high dose-rate interstitial brachytherapy followed by IMRT radiotherapy for intermediate and high risk prostate cancer

    International Nuclear Information System (INIS)

    Nakamura, Satoshi; Murakami, Naoya; Inaba, Koji; Wakita, Akihisa; Kobayashi, Kazuma; Takahashi, Kana; Okamoto, Hiroyuki; Umezawa, Rei; Morota, Madoka; Sumi, Minako; Igaki, Hiroshi; Ito, Yoshinori; Itami, Jun

    2016-01-01

    The study aimed to compare urinary symptoms in patients with clinically localized prostate cancer after a combination of either low-dose-rate or high-dose-rate interstitial brachytherapy along with intensity-modulated radiation therapy (LDR-ISBT + IMRT or HDR-ISBT + IMRT). From June 2009 to April 2014, 16 and 22 patients were treated with LDR-ISBT + IMRT and HDR-ISBT + IMRT, respectively. No patient from these groups was excluded from this study. The prescribed dose of LDR-ISBT, HDR-ISBT, and IMRT was 115 Gy, 20 Gy in 2 fractions, and 46 Gy in 23 fractions, respectively. Obstructive and irritative urinary symptoms were assessed by the International Prostate Symptom Score (IPSS) examined before and after treatments. After ISBT, IPSS was evaluated in the 1st and 4th weeks, then every 2–3 months for the 1st year, and every 6 months thereafter. The median follow-up of the patients treated with LDR-ISBT + IMRT and HDR-ISBT + IMRT was 1070.5 days and 1048.5 days, respectively (p = 0.321). The IPSS-increment in the LDR-ISBT + IMRT group was greater than that in the HDR-ISBT + IMRT between 91 and 180 days after ISBT (p = 0.015). In the LDR-ISBT + IMRT group, the IPSS took longer time to return to the initial level than in the HDR-ISBT + IMRT group (in LDR-ISBT + IMRT group, the recovery time was 90 days later). The dose to urethra showed a statistically significant association with the IPSS-increment in the irritative urinary symptoms (p = 0.011). Clinical outcomes were comparable between both the groups. Both therapeutic modalities are safe and well suited for patients with clinically localized prostate cancer; however, it took patients longer to recover from LDR-ISBT + IMRT than from HDR-ISBT + IMRT. It is possible that fast dose delivery induced early symptoms and early recovery, while gradual dose delivery induced late symptoms and late recovery. Urethral dose reductions were associated with small increments in IPSS

  15. High dose rate brachytherapy using custom made superficial mould applicators and Leipzig applicators for non melanoma localized skin cancer

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, A. Cassio A.; Miziara, Daniela; Lima, Flavia Pedroso de; Miziara, Miguel

    2014-07-01

    Purpose: advances in technology and the commercial production of Leipzig applicators allowed High Dose Rate after-load brachytherapy (HDR-BT) to address a number of the challenges associated with the delivery of superficial radiation to treat localized non melanoma skin cancer (NMSK). We reviewed our uni-institutional experience on the treatment of NMSK with HDR-BT. Methods: data were collected retrospectively from patients attending the Radiation Oncology Department at AV Carvalho Insitute, Sao Paulo, Brazil. HDR-BT was done using the stepping source HDR 192Ir Microselectron (Nucletron BV). The planning target volume consisted of the macroscopic lesion plus a 5mm to 10mm margin.The depth of treatment was 0.5 cm in smaller (< 2.0 cm) tumors and 10 to 15 mm for lesions bigger than that. Results: Thirteen patients were treated with HDR-BT from June, 2007 to June 2013. The median age and follow up time were 72 (38-90) years old and 36 (range, 7-73) months, respectively. There a predominance of males (61.5%) and of patients referred for adjuvant treatment due positive surgical margins or because they have had only a excision biopsy without safety margins (61.5%). Six (46.2%) patients presented with squamous cell carcinoma and 7 (53.8%) patients presented with basal cell carcinoma. The median tumor size was 20 (range, 5-42) mm. Patients were treated with a median total dose of 40 Gy (range, 20 -60), given in 10 (range, 2-15) fractions, given daily or twice a week. All patients responded very well to treatment and only one patient has failed locally so far, after 38 months of the end of the irradiation. The crude and actuarial 3-year local control rates were 100% and 80%, respectively. Moist desquamation, grade 2 RTOG, was observed in 4 (30.8%) patients. Severe late complication, radiation-induced dyspigmentation, occurred in 2 patients and 1 of the patients also showed telangiectasia in the irradiated area. The cosmetic result was considered good in 84% (11/13) patients

  16. High dose rate brachytherapy using custom made superficial mould applicators and Leipzig applicators for non melanoma localized skin cancer

    International Nuclear Information System (INIS)

    Pellizzon, A. Cassio A.; Miziara, Daniela; Lima, Flavia Pedroso de; Miziara, Miguel

    2014-01-01

    Purpose: advances in technology and the commercial production of Leipzig applicators allowed High Dose Rate after-load brachytherapy (HDR-BT) to address a number of the challenges associated with the delivery of superficial radiation to treat localized non melanoma skin cancer (NMSK). We reviewed our uni-institutional experience on the treatment of NMSK with HDR-BT. Methods: data were collected retrospectively from patients attending the Radiation Oncology Department at AV Carvalho Insitute, Sao Paulo, Brazil. HDR-BT was done using the stepping source HDR 192Ir Microselectron (Nucletron BV). The planning target volume consisted of the macroscopic lesion plus a 5mm to 10mm margin.The depth of treatment was 0.5 cm in smaller (< 2.0 cm) tumors and 10 to 15 mm for lesions bigger than that. Results: Thirteen patients were treated with HDR-BT from June, 2007 to June 2013. The median age and follow up time were 72 (38-90) years old and 36 (range, 7-73) months, respectively. There a predominance of males (61.5%) and of patients referred for adjuvant treatment due positive surgical margins or because they have had only a excision biopsy without safety margins (61.5%). Six (46.2%) patients presented with squamous cell carcinoma and 7 (53.8%) patients presented with basal cell carcinoma. The median tumor size was 20 (range, 5-42) mm. Patients were treated with a median total dose of 40 Gy (range, 20 -60), given in 10 (range, 2-15) fractions, given daily or twice a week. All patients responded very well to treatment and only one patient has failed locally so far, after 38 months of the end of the irradiation. The crude and actuarial 3-year local control rates were 100% and 80%, respectively. Moist desquamation, grade 2 RTOG, was observed in 4 (30.8%) patients. Severe late complication, radiation-induced dyspigmentation, occurred in 2 patients and 1 of the patients also showed telangiectasia in the irradiated area. The cosmetic result was considered good in 84% (11/13) patients

  17. Medically inoperable endometrial cancer in patients with a high body mass index (BMI): Patterns of failure after 3-D image-based high dose rate (HDR) brachytherapy

    DEFF Research Database (Denmark)

    Acharya, Sahaja; Esthappan, Jacqueline; Badiyan, Shahed

    2016-01-01

    the patterns of failure after definitive treatment with 3-D image-based high dose rate (HDR) brachytherapy for medically inoperable endometrial cancer. MATERIALS AND METHODS: Forty-three consecutive patients with endometrial cancer FIGO stages I-III were treated definitively with HDR brachytherapy...

  18. Prostate-specific antigen bounce after high-dose rate brachytherapy with external beam radiation therapy for prostate cancer patients

    International Nuclear Information System (INIS)

    Sakamoto, Naotaka; Kakinoki, Hiroaki; Tsutsui, Akio; Yoshikawa, Masahiro; Iguchi, Atsushi; Matsunobu, Toru; Uehara, Satoru

    2008-01-01

    Prostate-specific antigen (PSA) bounce after high-dose rate (HDR) brachytherapy with external beam radiation therapy (EBRT) for prostate cancer patients was evaluated. Sixty-one patients treated with HDR-brachytherapy followed by EBRT had a minimum follow-up of 12 months (median, 24 months) in our institute. A PSA bounce was defined as a rise of at least 0.1 ng/ml greater than a previous PSA level, with a subsequent decline equal to, or less than, the initial nadir. A PSA bounce was noted in 16 (26.2%) of 61 patients (one patient had a PSA bounce twice). Median time to develop a PSA bounce was 18 months, but 23.5% developed a PSA bounce after 24 months. Median duration of PSA bounce was 6 months and 11.8% had increased PSA within a period of 12 months. Median bounce height was 0.2 ng/ml (range, 0.1 to 3.39 ng/ml). A bounce height of gerater than 2 ng/ml was seen in 11.8%. Clinical characteristics (age, prostate volume, neoadjuvant endocrine therapy, risk classification, stage, pretreatment PSA, Gleason score) do not predict whether or not there will be a PSA bounce. In patients treated with HDR-brachytherapy followed by EBRT, the incidence and characteristics of PSA bounce were similar to those in patients treated with low-dose rate brachytherapy. Physicians should be aware of the possibility of PSA bounce following HDR-brachytherapy with EBRT. (author)

  19. Effect of rectal enemas on rectal dosimetric parameters during high-dose-rate vaginal cuff brachytherapy. A prospective trial

    Energy Technology Data Exchange (ETDEWEB)

    Sabater, Sebastia; Andres, Ignacio; Sevillano, Marimar; Berenguer, Roberto; Aguayo, Manuel; Villas, Maria Victoria [Complejo Hospitalario Universitario de Albacete (CHUA), Department of Radiation Oncology, Albacete (Spain); Gascon, Marina; Arenas, Meritxell [Hospital Universitari Sant Joan, Department of Radiation Oncology, Reus (Spain); Rovirosa, Angeles; Camacho-Lopez, Cristina [University of Barcelona, IDIBAPS, Gynecological Cancer Unit, Radiation Oncology Department, ICMHO, Hospital Clinic, Barcelona (Spain)

    2016-04-15

    To evaluate the effects of rectal enemas on rectal doses during postoperative high-dose-rate (HDR) vaginal cuff brachytherapy (VCB). This prospective trial included 59 patients. Two rectal cleansing enemas were self-administered before the second fraction, and fraction 1 was considered the basal status. Dose-volume histogram (DVH) values were generated for the rectum and correlated with rectal volume variation. Statistical analyses used paired and unpaired t-tests. Despite a significant 15 % reduction in mean rectal volume (44.07 vs. 52.15 cc, p = 0.0018), 35.6 % of patients had larger rectums after rectal enemas. No significant rectal enema-related DVH differences were observed compared to the basal data. Although not statistically significant, rectal cleansing-associated increases in mean rectal DVH values were observed: D{sub 0.1} {sub cc}: 6.6 vs. 7.21 Gy; D{sub 1} {sub cc}: 5.35 vs. 5.52 Gy; D{sub 2} {sub cc}: 4.67 vs. 4.72 Gy, before and after rectal cleaning, respectively (where D{sub x} {sub cc} is the dose to the most exposed x cm {sup 3}). No differences were observed in DVH parameters according to rectal volume increase or decrease after the enema. Patients whose rectal volume increased also had significantly larger DVH parameters, except for D{sub 5} {sub %}, D{sub 25} {sub %}, and D{sub 50} {sub %}. In contrast, in patients whose rectal volume decreased, significance was only seen for D{sub 25} {sub %} and D{sub 50} {sub %} (D{sub x} {sub %} dose covering x % of the volume). In the latter patients, nonsignificant reductions in D{sub 2} {sub cc}, D{sub 5} {sub cc} and V{sub 5} {sub Gy} (volume receiving at least 5 Gy) were observed. The current rectal enemas protocol was ineffective in significantly modifying rectal DVH parameters for HDR-VCB. (orig.) [German] Beurteilung der Auswirkungen von rektalen Dosen waehrend postoperativer High-Dose-Rate-(HDR-)Brachytherapie an der Scheidenmanschette (''vaginal cuff brachytherapy'', VCB). An

  20. High-Dose-Rate Brachytherapy Boost Effect on Local Tumor Control in Young Women With Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guinot, Jose-Luis, E-mail: jguinot@fivo.org [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Baixauli-Perez, Cristobal [Health Services Research Unit, Center for Public Health Research, Valencia (Spain); Soler, Pablo; Tortajada, Maria Isabel; Moreno, Araceli; Santos, Miguel Angel; Mut, Alejandro [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Gozalbo, Francisco [Department of Pathology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain); Arribas, Leoncio [Department of Radiation Oncology, Fundacion Instituto Valenciano de Oncologia, Valencia (Spain)

    2015-01-01

    Purpose: To evaluate the local control rate and complications of a single fraction of high-dose-rate brachytherapy (HDR BT) boost in women aged 45 yeas and younger after breast-conserving therapy. Methods and Materials: Between 1999 and 2007, 167 patients between the ages of 26 and 45 years old (72 were 40 years old or younger), with stages T1 to T2 invasive breast cancer with disease-free margin status of at least 5 mm after breast-conserving surgery received 46 to 50 Gy whole-breast irradiation plus a 7-Gy HDR-BT boost (“fast boost”). An axillary dissection was performed in 72.5% of the patients and sentinel lymph node biopsy in 27.5%. A supraclavicular area was irradiated in 19% of the patients. Chemotherapy was used in 86% of the patients and hormone treatment in 77%. Clinical nodes were present in 18% and pathological nodes in 29%. The pathological stage was pT0: 5%, pTis: 3%, pT1: 69% and pT2: 23%. Intraductal component was present in 40% and 28% were G3. Results: At a median follow-up of 92 months, 9 patients relapsed on the margin of the implant, and 1 patient in another quadrant, resulting in a 10-year local relapse rate of 4.3% and a breast relapse rate of 4.9%, with breast preservation in 93.4%; no case of mastectomy due to poor cosmesis arose. Actuarial 5- and 10-year disease-free, cause-specific, and overall survival rates were 87.9% and 85.8%, and 92.1% and 88.4%, and 92.1% and 87.3%, respectively. In a univariate analysis, triple-negative cases and negative hormone receptors did worse, but in a multivariate analysis, only the last factor was significant for local and breast control. Asymptomatic fibrosis G2 was recorded in 3 cases, and there were no other late complications. Cosmetic results were good to excellent in 97% of cases. Conclusions: A single dose of 7 Gy using the fast-boost technique is well tolerated, with a low rate of late complications and improved local tumor control in women aged 45 and younger, compared to published data

  1. Validation of MRI to TRUS registration for high-dose-rate prostate brachytherapy.

    Science.gov (United States)

    Poulin, Eric; Boudam, Karim; Pinter, Csaba; Kadoury, Samuel; Lasso, Andras; Fichtinger, Gabor; Ménard, Cynthia

    The objective of this study was to develop and validate an open-source module for MRI to transrectal ultrasound (TRUS) registration to support tumor-targeted prostate brachytherapy. In this study, 15 patients with prostate cancer lesions visible on multiparametric MRI were selected for the validation. T2-weighted images with 1-mm isotropic voxel size and diffusion weighted images were acquired on a 1.5T Siemens imager. Three-dimensional (3D) TRUS images with 0.5-mm slice thickness were acquired. The investigated registration module was incorporated in the open-source 3D Slicer platform, which can compute rigid and deformable transformations. An extension of 3D Slicer, SlicerRT, allows import of and export to DICOM-RT formats. For validation, similarity indices, prostate volumes, and centroid positions were determined in addition to registration errors for common 3D points identified by an experienced radiation oncologist. The average time to compute the registration was 35 ± 3 s. For the rigid and deformable registration, respectively, Dice similarity coefficients were 0.87 ± 0.05 and 0.93 ± 0.01 while the 95% Hausdorff distances were 4.2 ± 1.0 and 2.2 ± 0.3 mm. MRI volumes obtained after the rigid and deformable registration were not statistically different (p > 0.05) from reference TRUS volumes. For the rigid and deformable registration, respectively, 3D distance errors between reference and registered centroid positions were 2.1 ± 1.0 and 0.4 ± 0.1 mm while registration errors between common points were 3.5 ± 3.2 and 2.3 ± 1.1 mm. Deformable registration was found significantly better (p < 0.05) than rigid registration for all parameters. An open-source MRI to TRUS registration platform was validated for integration in the brachytherapy workflow. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  2. Independent assessment of source position for gynecological applicator in high-dose-rate brachytherapy.

    Science.gov (United States)

    Okamoto, Hiroyuki; Nakamura, Satoshi; Nishioka, Shie; Iijima, Kotaro; Wakita, Akihisa; Abe, Yukinao; Tohyama, Naoki; Kawamura, Shinji; Minemura, Toshiyuki; Itami, Jun

    2017-10-01

    The aim of this study is to describe a phantom designed for independent examination of a source position in brachytherapy that is suitable for inclusion in an external auditing program. We developed a phantom that has a special design and a simple mechanism, capable of firmly fixing a radiochromic film and tandem-ovoid applicators to assess discrepancies in source positions between the measurements and treatment planning system (TPS). Three tests were conducted: 1) reproducibility of the source positions ( n = 5); 2) source movements inside the applicator tube; 3) changing source position by changing curvature of the transfer tubes. In addition, as a trial study, the phantom was mailed to 12 institutions, and 23 trial data sets were examined. The source displacement ΔX and ΔY (reference = TPS) were expressed according to the coordinates, in which the positive direction on the X-axis corresponds to the external side of the applicator perpendicular to source transfer direction Y-axis. Test 1: The 1σ fell within 1 mm irrespective of the dwell positions. Test 2: ΔX were greater around the tip of the applicator owing to the source cable. Test 3: All of the source position changes fell within 1 mm. For postal audit, the mean and 1.96σ in ΔX were 0.8 and 0.8 mm, respectively. Almost all data were located within a positive region along the X-axis due to the source cable. The mean and 1.96σ in ΔY were 0.3 and 1.6 mm, respectively. The variance in ΔY was greater than that in ΔX, and large uncertainties exist in the determination of the first dwell position. The 95% confidence limit was 2.1 mm. In HDR brachytherapy, an effectiveness of independent source position assessment could be demonstrated. The 95% confidence limit was 2.1 mm for a tandem-ovoids applicator.

  3. Dose optimization of intra-operative high dose rate interstitial brachytherapy implants for soft tissue sarcoma

    Directory of Open Access Journals (Sweden)

    Jamema Swamidas

    2009-01-01

    Full Text Available Objective : A three dimensional (3D image-based dosimetric study to quantitatively compare geometric vs. dose-point optimization in combination with graphical optimization for interstitial brachytherapy of soft tissue sarcoma (STS. Materials and Methods : Fifteen consecutive STS patients, treated with intra-operative, interstitial Brachytherapy, were enrolled in this dosimetric study. Treatment plans were generated using dose points situated at the "central plane between the catheters", "between the catheters throughout the implanted volume", at "distances perpendicular to the implant axis" and "on the surface of the target volume" Geometrically optimized plans had dose points defined between the catheters, while dose-point optimized plans had dose points defined at a plane perpendicular to the implant axis and on the target surface. Each plan was graphically optimized and compared using dose volume indices. Results : Target coverage was suboptimal with coverage index (CI = 0.67 when dose points were defined at the central plane while it was superior when the dose points were defined at the target surface (CI=0.93. The coverage of graphically optimized plans (GrO was similar to non-GrO with dose points defined on surface or perpendicular to the implant axis. A similar pattern was noticed with conformity index (0.61 vs. 0.82. GrO were more conformal and less homogeneous compared to non-GrO. Sum index was superior for dose points defined on the surface of the target and relatively inferior for plans with dose points at other locations (1.35 vs. 1.27. Conclusions : Optimization with dose points defined away from the implant plane and on target results in superior target coverage with optimal values of other indices. GrO offer better target coverage for implants with non-uniform geometry and target volume.

  4. External beam radiotherapy boosted with high dose rate brachytherapy in completely resected uterine sarcomas. Is this a treatment option?

    International Nuclear Information System (INIS)

    Pellizzon, Antonio Cassio Assis; Novaes, Paulo Eduardo Ribeiro dos Santos; Maia, Maria Aparecida Conte; Ferrigno, Robson; Fogarolli, Ricardo; Salvajoli, Joao Vitor

    2005-01-01

    Uterine sarcoma (US) is a relative rare tumor, which accounts for only about 3-5% of all uterine cancers. Aggressive cytoreductive surgery at the time of the initial diagnosis with maximum tumor debulking may lead to a prolonged survival or cure. Objective: to identify and review the role of adjuvant external beam radiation therapy (EBRT) associated with high dose rate brachytherapy (HDRB) in the management of patients presenting US with complete resection. Material and methods: this study is a retrospective analysis of 23 patients with US treated from 10/92 to 03/03, with surgery, external beam radiation therapy (EBRT) and high dose rate brachytherapy (HDRB). The inclusion criteria for study participation included: histologically proven and graded US, completely resection of tumor, Karnofsky status 60-100, absence of significant infection, and recovery from recent surgery. Results: The median age of patients was 62 years (range 39-84); ten-year actuarial disease-free and overall survivals were 42.2% and 63.4%, respectively. On univariate analysis, predictive factors for disease-free survival (DFS) were age at initial presentation (p=0.0268), parity (p=0.0441), tumor grade (p= 0.0095), cervical or vaginal invasion (p=0.0014) and node dissection at time of surgery (p= 0.0471). On multivariate analysis, the only predictive factor was cervical or vaginal invasion (p= 0.048), hazard ratio of 4.7. Conclusion: it is quite likely that neither radiotherapy nor chemotherapy alone will appreciably improve survival in US. If radiation therapy provides better locoregional tumor control, hematogenous metastases will assume an even greater proportion of treatment failures. Unfortunately, our small and heterogeneous group analyzed precludes any definitive conclusions about the impact of HDRB associated to EBRT radiation therapy on recurrence or survival. (author)

  5. Proposal of a high dose rate brachytherapy model for in vitro radiobiology studies

    International Nuclear Information System (INIS)

    Geraldo, Jony M.; Nogueira, Luciana B.; Andrade, Lidia M.; Trindade, Cassia; Furtado, Clascidia A.; Ladeira, Luiz Orlando

    2016-01-01

    The aim of this research was to develop an easy and reproducible approach for experimental HDR brachytherapy allowing in vitro irradiation studies based on clinical parameters. An acrylic platform was designed to attach T25 tissue culture flasks and multi-well tissue culture plates as well as kept the catheters in a fixed position during irradiation. CT images were taken and the irradiation was planned for 550cGy dose applied on adherent tumor cells. Dosimetric measurements were done and all relevant uncertainties were taken into account in order to figure out the correct dose range received by the cells. Tumor cells were irradiated two times over an interval of 24h between irradiations. Proof of concepts of this approach was carried out by biological effects analysis using a radioresistant human epidermoid carcinoma A431 cell line. Cellular proliferation and cell cycle phase were assessed by Trypan blue exclusion assay and DNA content analysis by flow cytometry, respectively. This approach allowed uniform dose distribution around the arrangement in all types of tissue culture plastics evaluated. Corrections due to uncertainties were managed. Regarding in vitro assays there was a significant (p<0.05) decreasing of cellular proliferation rate in irradiated cells. Moreover, increased percentage of cells arrested in G2/M phase (32.3 ± 1.5%) were observed for treated group compared with untreated cells. (author)

  6. Independent verification of the delivered dose in High-Dose Rate (HDR) brachytherapy

    International Nuclear Information System (INIS)

    Portillo, P.; Feld, D.; Kessler, J.

    2009-01-01

    An important aspect of a Quality Assurance program in Clinical Dosimetry is an independent verification of the dosimetric calculation done by the Treatment Planning System for each radiation treatment. The present paper is aimed at creating a spreadsheet for the verification of the dose recorded at a point of an implant with radioactive sources and HDR in gynecological injuries. An 192 Ir source automatic differed loading equipment, GammaMedplus model, Varian Medical System with HDR installed at the Angel H. Roffo Oncology Institute has been used. The planning system implemented for getting the dose distribution is the BraquiVision. The sources coordinates as well as those of the calculation point (Rectum) are entered into the Excel-devised verification program by assuming the existence of a point source in each one of the applicators' positions. Such calculation point has been selected as the rectum is an organ at risk, therefore determining the treatment planning. The dose verification is performed at points standing at a sources distance having at least twice the active length of such sources, so they may be regarded as point sources. Most of the sources used in HDR brachytherapy with 192 Ir have a 5 mm active length for all equipment brands. Consequently, the dose verification distance must be at least of 10 mm. (author)

  7. Use of CT or MR dosimetry in high dose rate (HDR) brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Liu, C.; Das, R.; See, A.; Duchesne, G.M.; Van Dyk, S.; Tai, K.H.

    2003-01-01

    Brachytherapy (BT) has, in recent years, become a well-utilised treatment option for prostate cancer. Tumour control probability relies on accurate dosimetry, which in turn relies on the accurate definition of the prostate gland. In external beam radiotherapy and BT, MRI has been shown to be a superior imaging modality when delineating the prostate gland especially at the apex. To date, data on MRI planning in prostate BT has focussed mainly on permanent interstitial implants. No data currently exists comparing MRI vs CT planning in HDR BT and its subsequent impact on prostate dosimetry. To determine the effects of MRI vs CT in HDR BT with respect to prostatic volumes and normal tissue doses, with the evaluations made using dose-volume histograms (DVH). Dosimetry parameters derived using CT and MRI (T2 weighted) scans of 11 patients who had received TRUS guided implants for HDR BT, were compared using the PlatoTM computer planning system. Treatment plans were generated on volumes marked by the same radiation oncologist for each patient. Comparison was made of the treatment plans (dosimetry) between: 1. CT generated plans; 2. CT generated plans assessed using MRI marked volumes and 3. MRI generated plans. We confirm the previously reported results that CT scans can overestimate prostatic volumes compared with MRI. Variations were noted in CT and MRI based plans that may allow improved sparing of the rectum and urethra when using MRI planning. The main disadvantages of using MRI scans are access to facilities as well as identifying a dummy source to adequately define the tips of our catheters. It is feasible to utilise MRI scans for HDR BT planning. The clearer definition of anatomical structures has added advantages when contouring the prostate

  8. High dose-rate (HDR) conformal interstitial brachytherapy for locally recurrent rectal cancer. Real-time computed tomography (CT) fluoroscopy guidance and image-based treatment planning

    International Nuclear Information System (INIS)

    Sakurai, Hideyuki; Mitsuhashi, Norio; Muramatsu, Hiroyuki

    2000-01-01

    The aim of the study is to develop high dose-rate (HDR) conformal interstitial brachytherapy by means of combined real-time computed tomography (CT) fluoroscopy guidance with CT-based treatment planning for locally recurrent rectal carcinoma. The procedures of brachytherapy needle insertion were guided with a helical CT scanner providing real-time fluoroscopy reconstruction. A video monitor placed adjacent to the CT gantry simultaneously allowed the operator to see the process of needle insertion. CT images were transferred by an on-line system to the treatment-planning computer which reconstructed the implant needles and organ contours. The doses in planning target volume were normalized and geometrically optimized. The patients received a dose of 5 Gy per fraction on a daily hyperfractionation schedule at a total dose of 30-50 Gy with or without external radiation therapy. Nine patients were treated for this procedure. Thirteen to 36 needles (average 19.1) were successfully placed at the planning target volume in each patient. The average time for CT fluoroscopy was 370.1 seconds in each procedure. No accident was occurred during needle insertion, but one patient developed fibular nerve palsy after needle removal but gradually recovered. The CT-based treatment planning was faster and more accurate than projection reconstruction with conventional radiograms. Analysis of a dose volume histogram demonstrated conformal dose distribution of the target, while avoiding dose to normal structures with this method. Real-time CT fluoroscopy ensures safety and increases the accuracy of needle placement. Conformal high dose-rate (HDR) interstitial brachytherapy with CT-based treatment planning is an attractive method for locally recurrent rectal cancer. (author)

  9. High dose-rate (HDR) conformal interstitial brachytherapy for locally recurrent rectal cancer. Real-time computed tomography (CT) fluoroscopy guidance and image-based treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Hideyuki; Mitsuhashi, Norio; Muramatsu, Hiroyuki [Gunma Univ., Maebashi (Japan). School of Medicine] [and others

    2000-12-01

    The aim of the study is to develop high dose-rate (HDR) conformal interstitial brachytherapy by means of combined real-time computed tomography (CT) fluoroscopy guidance with CT-based treatment planning for locally recurrent rectal carcinoma. The procedures of brachytherapy needle insertion were guided with a helical CT scanner providing real-time fluoroscopy reconstruction. A video monitor placed adjacent to the CT gantry simultaneously allowed the operator to see the process of needle insertion. CT images were transferred by an on-line system to the treatment-planning computer which reconstructed the implant needles and organ contours. The doses in planning target volume were normalized and geometrically optimized. The patients received a dose of 5 Gy per fraction on a daily hyperfractionation schedule at a total dose of 30-50 Gy with or without external radiation therapy. Nine patients were treated for this procedure. Thirteen to 36 needles (average 19.1) were successfully placed at the planning target volume in each patient. The average time for CT fluoroscopy was 370.1 seconds in each procedure. No accident was occurred during needle insertion, but one patient developed fibular nerve palsy after needle removal but gradually recovered. The CT-based treatment planning was faster and more accurate than projection reconstruction with conventional radiograms. Analysis of a dose volume histogram demonstrated conformal dose distribution of the target, while avoiding dose to normal structures with this method. Real-time CT fluoroscopy ensures safety and increases the accuracy of needle placement. Conformal high dose-rate (HDR) interstitial brachytherapy with CT-based treatment planning is an attractive method for locally recurrent rectal cancer. (author)

  10. Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE.

    Science.gov (United States)

    Almansa, Julio F; Guerrero, Rafael; Torres, Javier; Lallena, Antonio M

    60 Co sources have been commercialized as an alternative to 192 Ir sources for high-dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is ∼0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of 60 Co, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  11. Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, George; Strom, Tobin J.; Shrinath, Kushagra; Mellon, Eric A.; Fernandez, Daniel C.; Biagioli, Matthew C. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Wilder, Richard B., E-mail: mcbiagioli@yahoo.com [Cancer Treatment Centers of America, Newnan, GA (United States)

    2015-05-15

    Purpose: to evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. Materials and methods: one hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. Results: median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p-0.04). There was no ≥ Grade 3 acute toxicity. Conclusions: dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes. (author)

  12. Dosimetric Coverage of the Prostate, Normal Tissue Sparing, and Acute Toxicity with High-Dose-Rate Brachytherapy for Large Prostate Volumes

    Directory of Open Access Journals (Sweden)

    George Yang

    2015-06-01

    Full Text Available ABSTRACTPurposeTo evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes.Materials and MethodsOne hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL were treated with high-dose-rate (HDR brachytherapy ± intensity modulated radiation therapy (IMRT to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38% unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.ResultsMedian follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3% patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17% patients developed Grade 2 acute urinary retention. American Urological Association (AUA symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04. There was no ≥ Grade 3 acute toxicity.ConclusionsDosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

  13. Chemoradiation in cervical cancer with cisplatin and high-dose rate brachytherapy combined with external beam radiotherapy. Results of a phase-II study

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, H.G.; Laban, C.; Puschmann, D.; Koelbl, H. [Dept. of Gynecology, Martin-Luther Univ. Halle-Wittenberg (Germany); Kuhnt, T.; Pigorsch, S.; Dunst, J.; Haensgen, G. [Dept. of Radiotherapy, Martin-Luther Univ. Halle-Wittenberg (Germany)

    2002-07-01

    Background: In 1999, five randomized studies demonstrated that chemoradiation with cisplatin and low-dose rate (LDR) brachytherapy has a benefit in locally advanced cervical cancer and for surgically treated patients in high-risk situations. We evaluated the safety and efficacy of concomitant chemoradiation with cisplatin and high-dose rate (HDR) brachytherapy in patients with cervical cancer. Patients and Method: 27 patients were included in our phase-II trial: 13 locally advanced cases (group A) and 14 adjuvant-therapy patients in high-risk situations (group B). A definitive radiotherapy was performed with 25 fractions of external beam therapy (1.8 Gy per fraction/middle shielded after eleven fractions). Brachytherapy was delivered at HDR schedules with 7 Gy in point A per fraction (total dose 35 Gy) in FIGO Stages IIB-IIIB. The total dose of external and brachytherapy was 70 Gy in point A and 52-54 Gy in point B. All patients in stage IVA were treated without brachytherapy. Adjuvant radiotherapy was performed with external beam radiotherapy of the pelvis with 1.8 Gy single-dose up to 50.4 Gy. Brachytherapy was delivered at HDR schedules with two fractions of 5 Gy only in patients with tumor-positive margins or tumor involvement of the upper vagina. The chemotherapeutic treatment schedule provided six courses of cisplatin 40 mg/m{sup 2} weekly recommended in the randomized studies GOG-120 and -123. Results: A total of 18/27 patients (66.7%) completed all six courses of chemotherapy. Discontinuation of radiotherapy due to therapy-related morbidity was not necessary in the whole study group. G3 leukopenia (29.6%) was the only relevant acute toxicity. There were no differences in toxicity between group A and B. Serious late morbidity occurred in 2/27 patients (7.4%). 12/13 patients (92.3%) with IIB-IVA cervical cancer showed a complete response (CR). 13/14 adjuvant cases (92.8%) are free of recurrence (median follow up: 19.1 months). Conclusion: Concomitant

  14. Image-Guided High-Dose Rate Brachytherapy in Cervix Carcinoma Using Balloon Catheter and Belt Immobilization System.

    Science.gov (United States)

    Fan, Qiyong; Yeung, Anamaria R; Amdur, Robert; Helmig, Richard; Park, Justin; Li, Jonathan; Kahler, Darren; Liu, Chihray; Lu, Bo

    2017-06-01

    The efficacy of image-guided high-dose rate brachytherapy for cervical cancer is limited by the ineffective rectal sparing devices available commercially and the potential applicator movement. We developed a novel device using a balloon catheter and a belt immobilization system, serving for rectal dose reduction and applicator immobilization purposes, respectively. The balloon catheter is constructed by gluing a short inflatable tube to a long regular open-end catheter. Contrast agent (10) cm 3 is injected into the inflatable end, which is affixed to the tandem and ring applicator, to displace the posterior vaginal wall. The belt immobilization system consists of a specially designed bracket that can hold and fix itself to the applicator, a diaper-like Velcro fastener package used for connecting the patient's pelvis to the bracket, and a buckle that holds the fasteners to stabilize the whole system. The treatment data for 21 patients with cervical cancer using both balloon catheter and belt immobilization system were retrospectively analyzed. Computed tomography and magnetic resonance images, acquired about 30 minutes apart, were registered to evaluate the effectiveness of the immobilization system. In comparison with a virtual rectal blade, the balloon decreased the rectal point dose by 34% ± 4.2% (from 276 ± 57 to 182 ± 38 cGy), corresponding to an extra sparing distance of 7.9 ± 1.1 mm. The maximum sparing distance variation per patient is 1.4 ± 0.6 mm, indicating the high interfractional reproducibility for rectum sparing. With the immobilization system, the mean translational and rotational displacements of the applicator set are <3 mm and <1.5°, respectively, in all directions. The rectal balloon provides significant dose reduction to the rectum and it may potentially minimize patient discomfort. The immobilization system permits almost no movement of the applicator during treatment. This work has the potential to be promoted as a standardized solution

  15. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V.

    1998-01-01

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  16. Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: Source dosimetry, treatment planning, equipment performance and in vivo verification techniques

    OpenAIRE

    Palmer, A; Bradley, D; Nisbet, A

    2012-01-01

    This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around...

  17. An analysis of acute complications and perioperative morbidity from high dose rate brachytherapy in the treatment of gynecological malignancies

    International Nuclear Information System (INIS)

    Sarkaria, Jann N.; Petereit, Daniel G.; Kinsella, Timothy J.; Buchler, Dolores A.

    1995-01-01

    Purpose: To evaluate the acute morbidity and mortality for high dose-rate (HDR) brachytherapy performed in an outpatient setting in the treatment of gynecological malignancies, and to identify possible risk factors for adverse outcomes. Materials and Methods: One hundred seventy-one patients with cervical (n=129) or uterine (n=42) carcinoma with an intact uterus were evaluated and treated from August 1989 through December 1994, with at least part of their therapy delivered with intracavitary HDR 192 Ir radiation. A total of 830 ICR insertions were performed with greater than 95% done on an outpatient basis under heavy intravenous sedation using fentanyl and midazolam. Perioperative morbidity and mortality were recorded for any event occurring within 30 days of the completion of therapy. Anesthesia risk was evaluated retrospectively in all patients based on the American Society of Anesthesiologists' (ASA) Physical Class System. Results: The uterine patients, many treated with radiation alone because of morbid obesity or medical inoperability, had a significantly higher perioperative morbidity and mortality rate as compared to the cervix patient cohort. Thirteen of the 42 (31%) uterine patients and 8 of the 129 (6%) cervix patients required hospitalization within 30 days of treatment completion (p 2) experienced greater morbidity and mortality, while the best predictor of complications in the cervix patients was age greater than 70 years. For the entire cohort of patients, no correlation was found between the 30 day morbidity and mortality and the doses of fentanyl and midazolam used or the length of the procedure. Conclusions: The acute complication rate from HDR brachytherapy performed on an outpatient basis with heavy intravenous sedation is acceptable for the great majority of patients who present for treatment. However, the high morbidity and mortality experienced by certain patient cohorts suggests that careful assessment of the risk/benefit ratio for treatment

  18. A hybrid evolutionary algorithm for multi-objective anatomy-based dose optimization in high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Lahanas, M; Baltas, D; Zamboglou, N

    2003-01-01

    Multiple objectives must be considered in anatomy-based dose optimization for high-dose-rate brachytherapy and a large number of parameters must be optimized to satisfy often competing objectives. For objectives expressed solely in terms of dose variances, deterministic gradient-based algorithms can be applied and a weighted sum approach is able to produce a representative set of non-dominated solutions. As the number of objectives increases, or non-convex objectives are used, local minima can be present and deterministic or stochastic algorithms such as simulated annealing either cannot be used or are not efficient. In this case we employ a modified hybrid version of the multi-objective optimization algorithm NSGA-II. This, in combination with the deterministic optimization algorithm, produces a representative sample of the Pareto set. This algorithm can be used with any kind of objectives, including non-convex, and does not require artificial importance factors. A representation of the trade-off surface can be obtained with more than 1000 non-dominated solutions in 2-5 min. An analysis of the solutions provides information on the possibilities available using these objectives. Simple decision making tools allow the selection of a solution that provides a best fit for the clinical goals. We show an example with a prostate implant and compare results obtained by variance and dose-volume histogram (DVH) based objectives

  19. A tool to automatically analyze electromagnetic tracking data from high dose rate brachytherapy of breast cancer patients

    Science.gov (United States)

    Lahmer, G.; Strnad, V.; Bert, Ch.; Hensel, B.; Tomé, A. M.; Lang, E. W.

    2017-01-01

    During High Dose Rate Brachytherapy (HDR-BT) the spatial position of the radiation source inside catheters implanted into a female breast is determined via electromagnetic tracking (EMT). Dwell positions and dwell times of the radiation source are established, relative to the patient’s anatomy, from an initial X-ray-CT-image. During the irradiation treatment, catheter displacements can occur due to patient movements. The current study develops an automatic analysis tool of EMT data sets recorded with a solenoid sensor to assure concordance of the source movement with the treatment plan. The tool combines machine learning techniques such as multi-dimensional scaling (MDS), ensemble empirical mode decomposition (EEMD), singular spectrum analysis (SSA) and particle filter (PF) to precisely detect and quantify any mismatch between the treatment plan and actual EMT measurements. We demonstrate that movement artifacts as well as technical signal distortions can be removed automatically and reliably, resulting in artifact-free reconstructed signals. This is a prerequisite for a highly accurate determination of any deviations of dwell positions from the treatment plan. PMID:28934238

  20. Comparison BIPM.RI(I)-K8 of high dose-rate Ir-192 brachytherapy standards for reference air kerma rate of the VSL and the BIPM

    DEFF Research Database (Denmark)

    Alvarez, J.T.; De Pooter, J.A.; Andersen, Claus E.

    2014-01-01

    An indirect comparison of the standards for reference air kerma rate for 192Ir high dose rate brachytherapy sources of the Dutch Metrology Institute (VSL), The Netherlands, and of the Bureau International des Poids et Mesures (BIPM) was carried out at the VSL in November 2009. The comparison resu...

  1. HDRMC, an accelerated Monte Carlo dose calculator for high dose rate brachytherapy with CT-compatible applicators

    Energy Technology Data Exchange (ETDEWEB)

    Chibani, Omar, E-mail: omar.chibani@fccc.edu; C-M Ma, Charlie [Fox Chase Cancer Center, Philadelphia, Pennsylvania 19111 (United States)

    2014-05-15

    Purpose: To present a new accelerated Monte Carlo code for CT-based dose calculations in high dose rate (HDR) brachytherapy. The new code (HDRMC) accounts for both tissue and nontissue heterogeneities (applicator and contrast medium). Methods: HDRMC uses a fast ray-tracing technique and detailed physics algorithms to transport photons through a 3D mesh of voxels representing the patient anatomy with applicator and contrast medium included. A precalculated phase space file for the{sup 192}Ir source is used as source term. HDRM is calibrated to calculated absolute dose for real plans. A postprocessing technique is used to include the exact density and composition of nontissue heterogeneities in the 3D phantom. Dwell positions and angular orientations of the source are reconstructed using data from the treatment planning system (TPS). Structure contours are also imported from the TPS to recalculate dose-volume histograms. Results: HDRMC was first benchmarked against the MCNP5 code for a single source in homogenous water and for a loaded gynecologic applicator in water. The accuracy of the voxel-based applicator model used in HDRMC was also verified by comparing 3D dose distributions and dose-volume parameters obtained using 1-mm{sup 3} versus 2-mm{sup 3} phantom resolutions. HDRMC can calculate the 3D dose distribution for a typical HDR cervix case with 2-mm resolution in 5 min on a single CPU. Examples of heterogeneity effects for two clinical cases (cervix and esophagus) were demonstrated using HDRMC. The neglect of tissue heterogeneity for the esophageal case leads to the overestimate of CTV D90, CTV D100, and spinal cord maximum dose by 3.2%, 3.9%, and 3.6%, respectively. Conclusions: A fast Monte Carlo code for CT-based dose calculations which does not require a prebuilt applicator model is developed for those HDR brachytherapy treatments that use CT-compatible applicators. Tissue and nontissue heterogeneities should be taken into account in modern HDR

  2. A novel adaptive needle insertion sequencing for robotic, single needle MR-guided high-dose-rate prostate brachytherapy

    Science.gov (United States)

    Borot de Battisti, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; Maenhout, M.; Moerland, M. A.

    2017-05-01

    MR-guided high-dose-rate (HDR) brachytherapy has gained increasing interest as a treatment for patients with localized prostate cancer because of the superior value of MRI for tumor and surrounding tissues localization. To enable needle insertion into the prostate with the patient in the MR bore, a single needle MR-compatible robotic system involving needle-by-needle dose delivery has been developed at our institution. Throughout the intervention, dose delivery may be impaired by: (1) sub-optimal needle positioning caused by e.g. needle bending, (2) intra-operative internal organ motion such as prostate rotations or swelling, or intra-procedural rectum or bladder filling. This may result in failure to reach clinical constraints. To assess the first aforementioned challenge, a recent study from our research group demonstrated that the deposited dose may be greatly improved by real-time adaptive planning with feedback on the actual needle positioning. However, the needle insertion sequence is left to the doctor and therefore, this may result in sub-optimal dose delivery. In this manuscript, a new method is proposed to determine and update automatically the needle insertion sequence. This strategy is based on the determination of the most sensitive needle track. The sensitivity of a needle track is defined as its impact on the dose distribution in case of sub-optimal positioning. A stochastic criterion is thus presented to determine each needle track sensitivity based on needle insertion simulations. To assess the proposed sequencing strategy, HDR prostate brachytherapy was simulated on 11 patients with varying number of needle insertions. Sub-optimal needle positioning was simulated at each insertion (modeled by typical random angulation errors). In 91% of the scenarios, the dose distribution improved when the needle was inserted into the most compared to the least sensitive needle track. The computation time for sequencing was less than 6 s per needle track. The

  3. Intraoperative High Dose Rate 32P Brachytherapy for Diffuse Recalcitrant Conjunctival Neoplasms: A Retrospective Case Series and Report of Toxicity

    Science.gov (United States)

    Marr, Brian P.; Abramson, David H.; Cohen, Gil’ad N.; Williamson, Matthew J.; McCormick, Beryl; Barker, Christopher A.

    2017-01-01

    improved in five of the seven eyes. Conclusions and Relevance Our results show the use of Intraoperative High Dose Rate 32P Brachytherapy in selected cases of recalcitrant diffuse conjunctival neoplasms. This technique offers a novel adjunct in the treatment of these cancers. Further follow-up and study is warranted. Trial Registration N/A PMID:25502420

  4. A dosimetric analysis of intensity-modulated radiation therapy (IMRT) as an alternative to adjuvant high-dose-rate (HDR) brachytherapy in early endometrial cancer patients.

    Science.gov (United States)

    Aydogan, Bulent; Mundt, Arno J; Smith, Brett D; Mell, Loren K; Wang, Steve; Sutton, Harold; Roeske, John C

    2006-05-01

    To evaluate the role of intensity-modulated radiation treatment (IMRT) as an alternative to high-dose-rate (HDR) brachytherapy in the treatment of the vagina in postoperative early endometrial cancer patients after surgery. Planning computed tomography (CT) scans of 10 patients previously treated with HDR were used in this study. In all cases, a dose of 700 cGy/fraction was prescribed at a distance of 0.5 cm from the cylinder surface. The same CT scans were then used in IMRT planning. In this paradigm, the vaginal cylinder represents a component of a hypothetical immobilization system that would be indexed to the linac treatment table. Our study showed that IMRT provided relatively lower rectal doses than HDR when treatment was prescribed at a distance of 0.5 cm away from the cylinder surface. Maximum rectal doses were lower with IMRT compared with HDR (average: 89.0% vs. 142.6%, respectively, p in IMRT plans compared with HDR plans with treatment prescribed either to the surface (average: 14.8% vs. 21.4%, respectively, p in conjunction with a suitable immobilization system, IMRT may provide an alternative to HDR brachytherapy in women with early endometrial cancer after hysterectomy. However, more studies are needed to evaluate the clinical merit of the IMRT in these patients.

  5. Quality assurance of Vari-source high dose rate (HDR) brachytherapy- remote after loader and cost effectiveness of Vari-source HDR- brachytherapy: NORI, Islamabad experience

    International Nuclear Information System (INIS)

    Ahmad, N.; Mahmood, H.; Jafri, S.R.A.

    2004-01-01

    A quality control of Vari-Source high dose rate (HDR) remote after loading brachytherapy machine was carried out and the cost effectiveness of HDR brachytherapy machine was also evaluated considering the cost of ten Iridium-192 wire sources at Nuclear Medicine, Oncology and Radiotherapy Institute (NORI), Islamabad, Pakistan. A total number of 253 intracavitary insertions were done in 98 patients from October 1996 to May 2001. The results of the quality control tests performed during 1996 to 2001 were within the acceptable limits. The cost effectiveness of Vari-Source HDR brachytherapy machine was also evaluated. The average cost per patient was calculated as US$ 491. Small number of patients was treated as the machine was used for gynecologic malignancies only. The objective was to assess the quality control status of HDR brachytherapy machine on patient treatment day, source exchange day and periodic day (monthly basis). It was found that the cost per patient can be minimized if other type of cancer patients are also treated on Vari-Source HDR machine. (author)

  6. Accelerated interstitial high dose rate brachytherapy as a boost technique in the treatment of soft tissue sarcomas

    International Nuclear Information System (INIS)

    Hixson, William C.; Raben, David; Jaffe, Kenneth A.; Salter, Merle M.

    1996-01-01

    Purpose/Objective: The efficacy of low dose rate (LDR) interstitial brachytherapy has clearly been established in the treatment of high grade soft tissue sarcomas. Our objective is to report the utility, technical considerations, and potential advantages of employing interstitial HDR brachytherapy as an adjuvant boost treatment for soft tissue sarcomas. Materials and Methods: Seventeen soft tissue sarcomas received HDR brachytherapy from 1990-1994. Two patients without follow-up were excluded. Sites of primary disease included the following: thigh (n=6), gluteal region (n=3), upper extremity (n=3), popliteal fossa (n=1), axilla (n=1), and chest wall (n=1). Ten of 15 lesions were grade II-III. Resection margins were negative (n=7), microscopically positive (n=7), or grossly positive (n=1). In 11 patients with previously untreated disease, postoperative HDR brachytherapy was delivered as adjuvant treatment in combination with either preoperative (n=5) or postoperative (n=6) external beam radiation therapy. Furthermore, 4 patients who had been previously irradiated and experienced recurrence underwent reresection followed by HDR brachytherapy boost; one of these patients also received additional postoperative external beam radiation therapy. In general, a delay of 2 - 3 weeks was allowed between preoperative external radiation therapy and surgery. A similar delay was employed between HDR brachytherapy and subsequent postoperative external radiation therapy. Median external beam radiation dose was 50.0 Gy, range 30.6 - 50.4 Gy. At the time of resection, blind end HDR catheters were implanted in a single plane in the tumor bed, spaced 1 cm apart, as defined by the surgical clips. The catheters were placed so as to extend 2 cm past the surgical clips in the cranio-caudad direction and 1 cm in the medial-lateral direction and stabilized with absorbable sutures. After allowing for five days of wound healing, BID brachytherapy (minimum inter-fraction interval 6 hours) was

  7. Bronchial mucosal tolerance following high dose rate endobronchial brachytherapy: clinical and laboratory correlates in late complication assessment of fatal hemoptysis

    International Nuclear Information System (INIS)

    Chen, Y.Y.; McDonald, S.; Nakamura, C.; Philips, A.; Ojomo, Karanita; Hernady, E.; Williams, J. P.; Smudzin, T.; Johnstone, D.; Feins, R.; Speiser, B.L.; Rubin, P.

    1996-01-01

    Purpose: This study reviews treatment related late complications following high dose rate endobronchial brachytherapy (HDR-EB) for primary lung cancers. Radiation dose contribution from HDR-EB treatment alone, or combined HDR-EB and external beam (EBRT) were analyzed in relation to the linear representation of the tracheobronchial anatomy. Results were presented in a dose volume histogram (DVH) analysis for the risk estimate of late complications from HDR-EB. Bronchial mucosal tolerance is estimated from the clinical experience study and histopathologic changes in laboratory animals treated with HDR-EB. Methods: 1.) There were forty one patients with primary lung cancer received HDR-EB as part of the radiation treatment between December 1990 and June 1994. Six of these developed late complications manifested as either fatal hemoptysis or endobronchial deposition of fibrinous material/bronchial stenosis. Treatment planning films were reviewed to map the volume treated with HDR-EB and EBRT along the tracheobronchial segments. DVH was constructed and compared for patients with and without late complications. Other clinical parameters of interest which were analyzed included: dose per fraction, EBRT total dose, HDR total dose, combined EBRT and HDR total dose, number of catheters per treatment, and points of prescriptions for HDR-EB. 2.) Forty four New Zealand White rabbits underwent HDR-EB of the major airway to a treatment length of 2 cm (1 cm above and below the carina) to a single fraction dose of 10 Gy, 30 Gy, or 50 Gy. Histopathologic changes were examined at 7, 14, 28, and 56 days post-treatment and compared with the control rabbits which received no irradiation. Results: 1.) The late complication rate is 14.5% with three patients developing fibrinous deposits/bronchial stenosis and four patients who experienced fatal hemoptysis in a total of six patients. There is a significant difference in DVH of HDR-EB treatment in the tracheobronchial high dose region

  8. Accuracy of applicator tip reconstruction in MRI-guided interstitial 192Ir-high-dose-rate brachytherapy of liver tumors

    International Nuclear Information System (INIS)

    Wybranski, Christian; Eberhardt, Benjamin; Fischbach, Katharina; Fischbach, Frank; Walke, Mathias; Hass, Peter; Röhl, Friedrich-Wilhelm; Kosiek, Ortrud; Kaiser, Mandy; Pech, Maciej; Lüdemann, Lutz; Ricke, Jens

    2015-01-01

    Background and purpose: To evaluate the reconstruction accuracy of brachytherapy (BT) applicators tips in vitro and in vivo in MRI-guided 192 Ir-high-dose-rate (HDR)-BT of inoperable liver tumors. Materials and methods: Reconstruction accuracy of plastic BT applicators, visualized by nitinol inserts, was assessed in MRI phantom measurements and in MRI 192 Ir-HDR-BT treatment planning datasets of 45 patients employing CT co-registration and vector decomposition. Conspicuity, short-term dislocation, and reconstruction errors were assessed in the clinical data. The clinical effect of applicator reconstruction accuracy was determined in follow-up MRI data. Results: Applicator reconstruction accuracy was 1.6 ± 0.5 mm in the phantom measurements. In the clinical MRI datasets applicator conspicuity was rated good/optimal in ⩾72% of cases. 16/129 applicators showed not time dependent deviation in between MRI/CT acquisition (p > 0.1). Reconstruction accuracy was 5.5 ± 2.8 mm, and the average image co-registration error was 3.1 ± 0.9 mm. Vector decomposition revealed no preferred direction of reconstruction errors. In the follow-up data deviation of planned dose distribution and irradiation effect was 6.9 ± 3.3 mm matching the mean co-registration error (6.5 ± 2.5 mm; p > 0.1). Conclusion: Applicator reconstruction accuracy in vitro conforms to AAPM TG 56 standard. Nitinol-inserts are feasible for applicator visualization and yield good conspicuity in MRI treatment planning data. No preferred direction of reconstruction errors were found in vivo

  9. Conventional High-Dose-Rate Brachytherapy With Concomitant Complementary IMRT Boost: A Novel Approach for Improving Cervical Tumor Dose Coverage

    International Nuclear Information System (INIS)

    Duan, Jun; Kim, Robert Y.; Elassal, Shaaban; Lin Huiyi; Shen Sui

    2008-01-01

    Purpose: To investigate the feasibility of combining conventional high-dose-rate (HDR) brachytherapy with a concomitant complementary intensity-modulated radiotherapy (IMRT) boost for improved target coverage in cervical cancers. Methods and Materials: Six patients with cervical cancer underwent conventional HDR (C-HDR) treatment. Computed tomography (CT) and magnetic resonance imaging (MRI) scans were acquired with a CT/MRI-compatible applicator in place. The clinical target volumes (CTVs), defined as the gross target volume with a 3-mm margin and the uterus, were delineated on the CT scans, along with the organs at risk (OARs). The IMRT plans were optimized to generate dose distributions complementing those of C-HDR to cover the CTV while maintaining low doses to the OARs (IMRT-HDR). For comparison, dwell-weight optimized HDR (O-HDR) plans were also generated to cover the CTV and spare the OARs. The three treatment techniques (C-HDR, O-HDR, and IMRT-HDR) were compared. The percentage of volume receiving 95% of the prescription dose (V 95 ) was used to evaluate dose coverage to the CTV, and the minimal doses in the 2.0-cm 3 volume receiving the greatest dose were calculated to compare the doses to the OARs. Results: The C-HDR technique provided very poor CTV coverage in 5 cases (V 95 95 ≥96.9%), it resulted in unacceptably high doses to the OARs in all 6 cases and unsatisfactory coverage to the whole CTV in 3 cases. IMRT-HDR not only yielded substantially improved CTV coverage (average V 95 = 95.3%), but also kept the doses to the bladder and rectum reasonably low. Conclusion: Compared with C-HDR and O-HDR, concomitant IMRT boost complementary to C-HDR not only provided excellent CTV coverage, but also maintained reasonably low doses to the OARs

  10. Intraoperative high-dose-rate brachytherapy for the treatment of pediatric tumors: the Ohio State University experience

    International Nuclear Information System (INIS)

    Nag, Subir; Tippin, Douglas; Ruymann, Frederick B.

    2001-01-01

    Purpose: To determine whether intraoperative high-dose-rate brachytherapy (IO-HDRBT) can be used to decrease the dose of external beam radiotherapy (EBRT) in the treatment of children with soft-tissue sarcomas and, thereby, reduce morbidity without compromising local control. Methods and Materials: From March 1992 through April 1999, 13 pediatric patients were treated with IO-HDRBT, low-dose EBRT, chemotherapy, and radical surgery at 21 sites that were not amenable to intraoperative electron beam therapy. The IO-HDRBT dose at 5 mm depth was 10 to 12.5 Gy for close margins/microscopic disease at 14 sites and 12.5 to 15 Gy for gross disease at 7 sites. The treatment volumes ranged from 4 to 96 cm 3 (mean 27). The EBRT dose was limited to 27-30 Gy in most cases to minimize growth retardation and preserve normal organ function. Results: After a median follow-up of 47 months (range 12-97), 11 patients were alive and without evidence of disease (overall survival rate 85%, 4-year actuarial survival rate 77%). Of the 2 who died, 1 had Stage III pulmonary blastoma with a sacral recurrence; the other had Stage IV undifferentiated synovial sarcoma with a pulmonary recurrence. One local failure occurred in a patient with gross residual disease after incomplete resection for Stage IV pulmonary blastoma. The local control rate was 95%, and morbidity was observed in 3 patients (23%). One patient developed impaired orbital growth with mild ptosis. Another patient required orthopedic pinning of her femoral subcapital epiphysis and construction of a neobladder secondary to urethral obstruction. The third patient required reimplantation of her autotransplanted kidney secondary to chronic urinary tract infection and ureteral reflux. Conclusions: IO-HDRBT allowed for reduction in EBRT without compromising local control or disease-free survival in children with soft-tissue sarcomas. Tumor beds inaccessible to electron beam methods could be satisfactorily encompassed with IO

  11. Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions

    Energy Technology Data Exchange (ETDEWEB)

    Candela-Juan, C., E-mail: ccanjuan@gmail.com [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and National Dosimetry Centre (CND), Valencia 46009 (Spain); Niatsetski, Y. [Elekta Brachytherapy, Veenendaal 3905 TH (Netherlands); Laarse, R. van der [Quality Radiation Therapy BV, Zeist 3707 HB (Netherlands); Granero, D. [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ballester, F. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Perez-Calatayud, J. [Radiation Oncology Department, La Fe University and Polytechnic Hospital, Valencia 46026, Spain and Department of Radiotherapy, Clínica Benidorm, Benidorm 03501 (Spain); Vijande, J. [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100, Spain and Instituto de Física Corpuscular (UV-CSIC), Burjassot 46100 (Spain)

    2016-04-15

    Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a {sup 192}Ir source; (ii) to calculate by means of the Monte Carlo (MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The PENELOPE2008 MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution around the applicator were calculated. Finally, MC data were validated experimentally for a {sup 192}Ir mHDR-v2 source by measuring (i) dose distributions with radiochromic EBT3 films (ISP); (ii) percentage depth–dose (PDD) curve with the parallel-plate ionization chamber Advanced Markus (PTW); and (iii) absolute dose rate with EBT3 films and the PinPoint T31016 (PTW) ionization chamber. Results: The new applicator is made of tungsten alloy (Densimet) and consists of a set of interchangeable collimators. Three catheters are used to allocate the source at prefixed dwell positions with preset weights to produce a homogenous dose distribution at the typical prescription depth of 3 mm in water. The same plan is used for all available collimators. PDD, absolute dose rate per unit of air kerma strength, and off-axis profiles in a cylindrical water phantom are reported. These data can be used for treatment planning. Leakage around the applicator was also scored. The dose distributions, PDD, and absolute dose rate calculated agree within experimental uncertainties with the doses measured: differences of MC data with chamber measurements are up to 0.8% and with radiochromic films are up to 3.5%. Conclusions: The new applicator and the dosimetric data provided here will be a valuable

  12. Late rectal bleeding and genitourinary morbidity after high dose rate brachytherapy combined with hypofractionated external beam radiotherapy for localized prostate cancer

    International Nuclear Information System (INIS)

    Ebara, Takeshi; Akimoto, Tetsuo; Kato, Hiroyuki

    2007-01-01

    The purpose of this study was to evaluate late rectal bleeding and genitourinary (GU) morbidity in patients consecutively treated with combined high-dose-rate (HDR) brachytherapy and external beam radiation therapy (EBRT). Data from 80 patients treated consecutively from October 2000 to May 2004 were analyzed. The median age was 69 years old, median follow-up 31 months, ranging from 17-59 months. All patients received endocrine therapy before radiation therapy. The patients were divided into low-, intermediate- and high-risk groups (4/24/52 patients) according to the risk factors defined by T-classification, prostatic specific antigen (PSA) and Gleason score. Fractionation schedules for HDR brachytherapy were prospectively changed, and EBRT was fixed with 3 Gy fractions to 51 Gy. The distribution of fractionation was scheduled as follows; 5 Gy x 5 times in 14 patients, 7 Gy x 3 times in 19 patients, and 9 Gy x 2 times in 47 patients. The rectal bleeding was graded using the toxicity criteria of the Radiation Therapy Oncology Group and European Organization for Research and Treatment of Cancer while the genitourinary morbidities were graded using the toxicity criteria of the Common Terminology Criteria for Adverse Events v.3.0. Grade 2 or worse rectal bleeding developed in 9 patients (11.3%) with the 2-year actuarial probability at 11.2%. Grade 2 and 3 rectal bleeding was recognized in 8 and 1 patients, respectively. Grade 3 morbidity developed in the biopsied sites that were performed in the other hospital. No significant difference was observed in any HDR brachytherapy fractionation schedule. Grade 2 or worse GU morbidities were recognized in 30 patients (37.5%), consisting of 29 Grade 2 patients and 1 Grade 3 patient. Twenty-one patients in Grade 2 morbidity had an increase in the frequency of urination or nocturia, and urethral strictures developed in 3 patients. The 3-year actuarial probability of urethral stricture was 6.0%. One patient experienced Grade 3

  13. American Society for Radiation Oncology (ASTRO) and American College of Radiology (ACR) practice guideline for the performance of high-dose-rate brachytherapy.

    Science.gov (United States)

    Erickson, Beth A; Demanes, D Jeffrey; Ibbott, Geoffrey S; Hayes, John K; Hsu, I-Chow J; Morris, David E; Rabinovitch, Rachel A; Tward, Jonathan D; Rosenthal, Seth A

    2011-03-01

    High-Dose-Rate (HDR) brachytherapy is a safe and efficacious treatment option for patients with a variety of different malignancies. Careful adherence to established standards has been shown to improve the likelihood of procedural success and reduce the incidence of treatment-related morbidity. A collaborative effort of the American College of Radiology (ACR) and American Society for Therapeutic Radiation Oncology (ASTRO) has produced a practice guideline for HDR brachytherapy. The guideline defines the qualifications and responsibilities of all the involved personnel, including the radiation oncologist, physicist and dosimetrists. Review of the leading indications for HDR brachytherapy in the management of gynecologic, thoracic, gastrointestinal, breast, urologic, head and neck, and soft tissue tumors is presented. Logistics with respect to the brachytherapy implant procedures and attention to radiation safety procedures and documentation are presented. Adherence to these practice guidelines can be part of ensuring quality and safety in a successful HDR brachytherapy program. Copyright © 2011. Published by Elsevier Inc.

  14. Comparison of192Ir,169Yb, and60Co high-dose rate brachytherapy sources for skin cancer treatment.

    Science.gov (United States)

    Safigholi, Habib; Meigooni, Ali S; Song, William Y

    2017-09-01

    To evaluate the possibility of utilizing the high-dose rate (HDR) 169 Yb and 60 Co sources, in addition to 192 Ir, for the treatment of skin malignancies with conical applicators. Monte Carlo (MC) simulations were used to benchmark the dosimetric parameters of single 169 Yb (4140), 60 Co (Co0.A86), and 192 Ir (mHDR-V2) brachytherapy sources in a water phantom and compared their results against published data. A standard conical tungsten alloy Leipzig-style applicator (Stand.Appl) was used for determination of the dose distributions at various depths with a single dwell position of the HDR sources. The HDR sources were modeled with its long axis parallel to the treatment plane within the opening section of the applicator. The source-to-surface distance (SSD) was 1.6 cm, which included a 0.1 cm thick removable plastic end-cap used for clinical applications. The prescription depth was considered to be 0.3 cm in a water phantom following the definitions in the literature for this treatment technique. Dose distributions generated with the Stand.Appl and the 169 Yb and 60 Co sources have been compared with those of the 192 Ir source, for the same geometry. Then, applicator wall thickness for the 60 Co source was increased (doubled) in MC simulations in order to minimize the leakage dose and penumbra to levels that were comparable to that from the 192 Ir source. For each source-applicator combination, the optimized plastic end-cap dimensions were determined in order to avoid over-dosage to the skin surface. The normalized dose profiles at the prescription depth for the 169 Yb-Stand.Appl and the 60 Co-double-wall applicator were found to be similar to that of the 192 Ir-Stand.Appl, with differences Ir-, 169 Yb- and 60 Co-Stand.Appl were found to be comparable to the values with the 60 Co-double-walled applicator, with differences Ir-, 169 Yb-Stand.Appl, and 60 Co-double-wall applicators respectively. The leakage dose around the Stand.Appl for distance > 2 cm from the

  15. Clinicopathologic Comparison of High-Dose-Rate Endorectal Brachytherapy versus Conventional Chemoradiotherapy in the Neoadjuvant Setting for Resectable Stages II and III Low Rectal Cancer

    Directory of Open Access Journals (Sweden)

    Jessica A. Smith

    2012-01-01

    Full Text Available Purpose. To assess for differences in clinical, radiologic, and pathologic outcomes between patients with stage II-III rectal adenocarcinoma treated neoadjuvantly with conventional external beam radiotherapy (3D conformal radiotherapy (3DRT or intensity-modulated radiotherapy (IMRT versus high-dose-rate endorectal brachytherapy (EBT. Methods. Patients undergoing neoadjuvant EBT received 4 consecutive daily 6.5 Gy fractions without chemotherapy, while those undergoing 3DRT or IMRT received 28 daily 1.8 Gy fractions with concurrent 5-fluorouracil. Data was collected prospectively for 7 EBT patients and retrospectively for 25 historical 3DRT/IMRT controls. Results. Time to surgery was less for EBT compared to 3DRT and IMRT (P<0.001. There was a trend towards higher rate of pathologic CR for EBT (P=0.06. Rates of margin and lymph node positivity at resection were similar for all groups. Acute toxicity was less for EBT compared to 3DRT and IMRT (P=0.025. Overall and progression-free survival were noninferior for EBT. On MRI, EBT achieved similar complete response rate and reduction in tumor volume as 3DRT and IMRT. Histopathologic comparison showed that EBT resulted in more localized treatment effects and fewer serosal adhesions. Conclusions. EBT offers several practical benefits over conventional radiotherapy techniques and appears to be at least as effective against low rectal cancer as measured by short-term outcomes.

  16. Investigation of Interfraction Variations of MammoSite Balloon Applicator in High-Dose-Rate Brachytherapy of Partial Breast Irradiation

    International Nuclear Information System (INIS)

    Kim, Yongbok; Johnson, Mark M.S.; Trombetta, Mark G.; Parda, David S.; Miften, Moyed

    2008-01-01

    Purpose: To measure the interfraction changes of the MammoSite applicator and evaluate their dosimetric effect on target coverage and sparing of organs at risk. Methods and Materials: A retrospective evaluation of the data from 19 patients who received 10 fractions (34 Gy) of high-dose-rate partial breast irradiation was performed. A computed tomography-based treatment plan was generated for Fraction 1, and a computed tomography scan was acquired just before the delivery of each fraction to ensure a consistent shape of the balloon. The eccentricity, asymmetry, and planning target volume (PTV) for plan evaluation purposes (PTV E VAL), as well as trapped air gaps, were measured for all patients. Furthermore, 169 computed tomography-based treatment plans were retrospectively generated for Fractions 2-10. Interfraction dosimetric variations were evaluated using the %PTV E VAL coverage, target dose homogeneity index, target dose conformal index, and maximum doses to the organs at risks. Results: The average variation of eccentricity and asymmetry from Fraction 1 values of 3.5% and 1.1 mm was -0.4% ± 1.6% and -0.1 ± 0.6 mm. The average trapped air gap volume was dramatically reduced from before treatment (3.7 cm 3 ) to Fraction 1 (0.8 cm 3 ). The PTV E VAL volume change was insignificant. The average variation for the %PTV E VAL, target dose homogeneity, and target dose conformal index from Fraction 1 values of 94.7%, 0.64, and 0.85 was 0.15% ± 2.4%, -0.35 ± 2.4%, and -0.34 ± 4.9%, respectively. The average Fraction 1 maximum skin and ipsilateral lung dose of 3.2 Gy and 2.0 Gy varied by 0.08 ± 0.47 and -0.16 ± 0.29 Gy, respectively. Conclusion: The interfraction variations were patient specific and fraction dependent. Although the average interfraction dose variations for the target and organs at risk were not clinically significant, the maximum variations could be clinically significant

  17. Genitourinary Toxicity After High-Dose-Rate (HDR) Brachytherapy Combined With Hypofractionated External Beam Radiotherapy for Localized Prostate Cancer: An Analysis to Determine the Correlation Between Dose-Volume Histogram Parameters in HDR Brachytherapy and Severity of Toxicity

    International Nuclear Information System (INIS)

    Ishiyama, Hiromichi; Kitano, Masashi; Satoh, Takefumi; Kotani, Shouko; Uemae, Mineko; Matsumoto, Kazumasa; Okusa, Hiroshi; Tabata, Ken-ichi; Baba, Shiro; Hayakawa, Kazushige

    2009-01-01

    Purpose: To evaluate the severity of genitourinary (GU) toxicity in high-dose-rate (HDR) brachytherapy combined with hypofractionated external beam radiotherapy (EBRT) for prostate cancer and to explore factors that might affect the severity of GU toxicity. Methods and Materials: A total of 100 Japanese men with prostate cancer underwent 192 Ir HDR brachytherapy combined with hypofractionated EBRT. Mean (SD) dose to 90% of the planning target volume was 6.3 (0.7) Gy per fraction of HDR. After 5 fractions of HDR treatment, EBRT with 10 fractions of 3 Gy was administrated. The urethral volume receiving 1-15 Gy per fraction in HDR brachytherapy (V1-V15) and the dose to at least 5-100% of urethral volume in HDR brachytherapy (D5-D100) were compared between patients with Grade 3 toxicity and those with Grade 0-2 toxicity. Prostate volume, patient age, and International Prostate Symptom Score were also compared between the two groups. Results: Of the 100 patients, 6 displayed Grade 3 acute GU toxicity, and 12 displayed Grade 3 late GU toxicity. Regarding acute GU toxicity, values of V1, V2, V3, and V4 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Regarding late GU toxicity, values of D70, D80, V12, and V13 were significantly higher in patients with Grade 3 toxicity than in those with Grade 0-2 toxicity. Conclusions: The severity of GU toxicity in HDR brachytherapy combined with hypofractionated EBRT for prostate cancer was relatively high. The volume of prostatic urethra was associated with grade of acute GU toxicity, and urethral dose was associated with grade of late GU toxicity.

  18. Prostate-specific antigen nadir after high-dose-rate brachytherapy predicts long-term survival outcomes in high-risk prostate cancer

    Directory of Open Access Journals (Sweden)

    Hideyasu Tsumura

    2016-04-01

    Full Text Available Purpose : To evaluate the prognostic value of prostate-specific antigen nadir (nPSA after high-dose-rate (HDR brachytherapy in clinically non-metastatic high-risk prostate cancer patients. Material and methods : Data from 216 patients with high-risk or locally advanced prostate cancer who underwent HDR brachytherapy and external beam radiation therapy with long-term androgen deprivation therapy (ADT between 2003 and 2008 were analyzed. The median prostate-specific antigen (PSA level at diagnosis was 24 ng/ml (range: 3-338 ng/ml. The clinical stage was T1c-2a in 55 cases (26%, T2b-2c in 48 (22%, T3a in 75 (35%, and T3b-4 in 38 (17%. The mean dose to 90% of the planning target volume was 6.3 Gy/fraction of HDR brachytherapy. After 5 fractions, external beam radiation therapy with 10 fractions of 3 Gy was administered. All patients initially underwent neoadjuvant ADT for at least 6 months, and adjuvant ADT was continued for 36 months. The median follow-up was 7 years from the start of radiotherapy. Results : The 7-year PSA relapse-free rate among patients with a post-radiotherapy nPSA level of ≤ 0.02 ng/ml was 94%, compared with 23% for patients with higher nPSA values (HR = 28.57; 95% CI: 12.04-66.66; p < 0.001. Multivariate analysis revealed that the nPSA value after radiotherapy was a significant independent predictor of biochemical failure, whereas pretreatment predictive values for worse biochemical control including higher level of initial PSA, Gleason score ≥ 8, positive biopsy core rate ≥ 67%, and T3b-T4, failed to reach independent predictor status. The 7-year cancer-specific survival rate among patients with a post-radiotherapy nPSA level of ≤ 0.02 ng/ml was 99%, compared with 82% for patients with higher nPSA values (HR = 32.25; 95% CI: 3.401-333.3; p = 0.002. Conclusions : A post-radiotherapy nPSA value of ≤ 0.02 ng/ml was associated with better long-term biochemical tumor control even if patients had pretreatment predictive

  19. Determination of Prognostic Factors for Vaginal Mucosal Toxicity Associated With Intravaginal High-Dose Rate Brachytherapy in Patients With Endometrial Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Bahng, Agnes Y.; Dagan, Avner [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States); Bruner, Deborah W. [University of Pennsylvania School of Nursing, Philadelphia, PA (United States); Lin, Lilie L., E-mail: lin@xrt.upenn.edu [Department of Radiation Oncology, University of Pennsylvania School of Medicine, Philadelphia, PA (United States)

    2012-02-01

    Purpose: The objective of this study was to determine the patient- and treatment-related prognostic factors associated with vaginal toxicity in patients who received intravaginal high dose rate (HDR) brachytherapy alone as adjuvant treatment for endometrial cancer. Secondary goals of this study included a quantitative assessment of optimal dilator use frequency and a crude assessment of clinical predictors for compliant dilator use. Methods and Materials: We retrospectively reviewed the charts of 100 patients with histologically confirmed endometrial cancer who underwent total hysterectomy and bilateral salpingo-oophorectomy with or without lymph node dissection and adjuvant intravaginal brachytherapy between 1995 and 2009 at the Hospital of University of Pennsylvania. The most common treatment regimen used was 21 Gy in three fractions (71 patients). Symptoms of vaginal mucosal toxicity were taken from the history and physical exams noted in the patients' charts and were graded according to the Common Toxicity Criteria for Adverse Events v. 4.02. Results: The incidence of Grade 1 or asymptomatic vaginal toxicity was 33% and Grade 2-3 or symptomatic vaginal toxicity was 14%. Multivariate analysis of age, active length, and dilator use two to three times a week revealed odds ratios of 0.93 (p = 0.013), 3.96 (p = 0.008), and 0.17 (p = 0.032) respectively. Conclusion: Increasing age, vaginal dilator use of at least two to three times a week, and shorter active length were found to be significantly associated with a decreased risk of vaginal stenosis. Future prospective studies are necessary to validate our findings.

  20. The usefulness of metal markers for CTV-based dose prescription in high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yoshida, Ken; Mitomo, Masanori; Nose, Takayuki; Koizumi, Masahiko; Nishiyama, Kinji; Yoshida, Mineo

    2002-01-01

    We employ a clinical target volume (CTV)-based dose prescription for high-dose-rate (HDR) interstitial brachytherapy. However, it is not easy to define CTV and organs at risk (OAR) from X-ray film or CT scanning. To solve this problem, we have utilized metal markers since October 1999. Moreover, metal markers can help modify dose prescription. By regulating the doses to the metal markers, refining the dose prescription can easily be achieved. In this research, we investigated the usefulness of the metal markers. Between October 1999 and May 2001, 51 patients were implanted with metal markers at Osaka Medical Center for Cancer and Cardiovascular Diseases (OMCC), Osaka National Hospital (ONH) and Sanda City Hospital (SCH). Forty-nine patients (head and neck: 32; pelvis: 11; soft tissue: 3; breast: 3) using metal markers were analyzed. During operation, we implanted 179 metal markers (49 patients) to CTV and 151 markers (26 patients) to OAR. At treatment planning, CTV was reconstructed judging from the metal markers, applicator position and operation records. Generally, we prescribed the tumoricidal dose to an isodose surface that covers CTV. We also planned to limit the doses to OAR lower than certain levels. The maximum normal tissue doses were decided 80%, 150%, 100%, 50% and 200% of the prescribed doses for the rectum, the urethra, the mandible, the skin and the large vessel, respectively. The doses to the metal markers using CTV-based dose prescription were generated. These were compared with the doses theoretically calculated with the Paris system. Treatment results were also investigated. The doses to the 158 metal markers (42 patients) for CTV were higher than ''tumoricidal dose''. In 7 patients, as a result of compromised dose prescription, 9 markers were lower than the tumoricidal dose. The other 12 markers (7%) were excluded from dose evaluation because they were judged as miss-implanted. The doses to the 142 metal markers (24 patients) for OAR were lower

  1. Analysis of the high dose rate brachytherapy protocols of quality assurance programs of some local services, based on T G 40, T G 56 and ARCAL 30

    International Nuclear Information System (INIS)

    Guzman Calcina, Carmen S.; Almeida, Adelaide de; Rocha, Jose R. Oliveira; Universidade Estadual de Campinas, SP

    2001-01-01

    High dose rate brachytherapy has been increasingly recognized in most countries, and radiotherapy services using this equipment are encouraged to have a very efficient quality assurance program to ensure protection for patients, workers and other personnel involved. The objective of this paper was to determine the types of tests for high dose rate equipment required by official protocols (TG 40, TG 56 and ARCAL XXX) and to compare them with the types of tests utilized by some radiotherapy services. We concluded that: the protocol TG 56 is more extensive and complete than the other official protocols (T G 40 and ARCAL XXX); the protocols used by the services evaluated on this study were based on the protocol TG 56, and were concordant with the other official protocols. In these protocols annual tests were frequently replaced by tests performed quarterly or twice a year. This study established the types of test used and their frequency of utilization, and permitted the design of an optimized protocol that may help in the implementation of basic and indispensable tests in order to ensure patient adequate treatment and safety to personnel involved, and consequently improve high dose rate brachytherapy quality assurance. (author)

  2. SU-E-T-383: Can Stereotactic Body Radiotherapy Mimic the Dose Distribution of High-Dose-Rate Tandem and Ovoids/ring Brachytherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Park, S; Demanes, J; Kamrava, M [UCLA School of Medicine, Los Angeles, CA (United States); Scanderbeg, D [UCSD Medical Center, La Jolla, CA (United States)

    2014-06-01

    Purpose: To investigate whether stereotactic body radiotherapy (SBRT) using volumetric modulated arc therapy (VMAT) can mimic the dosimetry of tandem and ovoids/ring brachytherapy. Methods: We selected 5 patients treated with 3D-CT based high-dose rate (HDR) brachytherapy using 4 tandem and ovoid and 1 tandem and ring case. Manual optimization based on the Manchester system followed by graphical optimization (Nucletron Oncentra MasterPlan or Varian BrachyVision) was performed to deliver 6.0 Gy per fraction to a high-risk CTV while maintaining dose to organs at risk (OAR) below the ABS recommendations. For theoretical SBRT plans, CT images and OAR contours from the HDR plans were imported into Eclipse (Varian). The SBRT plan was created to mimic the heterogeneity of HDR plans by using a simultaneous integrated boost technique to match the V100, V150, and V200 isodose volumes from HDR. The OAR Dmax from HDR was used to define the OAR dose constraints for SBRT. Target coverage, dose spill-out, and OAR doses (D0.1cc, D1cc, and D2cc) between the HDR and SBRT plans were compared for significance using a two-tail paired ttest. Results: The mean isodose volumes for HDR vs. SBRT were 29.4 cc vs. 29.0 cc (V200, p = 0.674), 49.2 cc vs. 56.3 cc (V150, p = 0.017), 95.4 cc vs. 127.7 cc (V100, p = 0.001), and 271.9 cc vs. 581.6 cc (V50, p = 0.001). The D2cc to OAR for HDR vs. SBRT was 71.6% vs. 96.2% (bladder, p = 0.002), 69.2% vs. 101.7% (rectum, p = 0.0003), and 56.9% vs. 68.6% (sigmoid, p = 0.004). Conclusion: SBRT with VMAT can provide similar dose target coverage (V200), but dose spill-out and doses to OAR were statistically significantly higher than HDR. This study clearly demonstrated that brachytherapy can not be substituted with SBRT in gynecologic cervical cancer treatment.

  3. Study of dosimetric variation due to interfraction organ movement in High Dose Rate Interstital (MUPIT) brachytherapy for gynecologic malignancies

    Science.gov (United States)

    Velmurugan, Thanigaimalai; Sukumar, Prabakar; Krishnappan, Chokkalingam; Boopathy, Raghavendiran

    2010-01-01

    Ten patients with cancer of uterine cervix who underwent interstitial brachytherapy using MUPIT templates were CT scanned (CT1) using which bladder, rectum and CTV were delineated. The treatment plan PCT1 was generated and optimized geometrically on the volume. CT scan (CT2) was repeated before the second fraction of the treatment CTV and critical organs were delineated. The plan (PCT2) was created by reproducing the Plan PCT1 in the CT2 images and compared with PCT1. Bladder, Rectum and CTV percentage volume variation ranges from +28.6% to -34.3%, 38.4% to -14.9% and 8.5% to -15.2% respectively. Maximum dose variation in bladder was +17.1%, in rectum was up to +410% and in CTV was -13.0%. The dose to these structures varies independently with no strong correlation with the volume variation. Hence it is suggested that repeat CT and re-planning is mandatory before second fraction execution.

  4. SU-E-T-232: Custom High-Dose-Rate Brachytherapy Surface Mold Applicators: The Importance Source to Skin Distance

    International Nuclear Information System (INIS)

    Park, S; Demanes, J; Kamrava, M

    2015-01-01

    Purpose: Surface mold applicators can be customized to fit irregular skin surfaces that are difficult to treat with other radiation therapy techniques. Optimal design of customized HDR skin brachytherapy is not well-established. We evaluated the impact of applicator thickness (source to skin distance) on target dosimetry. Methods: 27 patients had 34 treated sites: scalp 4, face 13, extremity 13, and torso 4. Custom applicators were constructed from 5–15 mm thick thermoplastic bolus molded over the skin lesion. A planar array of plastic brachytherapy catheters spaced 5–10 mm apart was affixed to the bolus. CT simulation was used to contour the target volume and to determine the prescription depth. Inverse planning simulated annealing followed by graphical optimization was used to plan and deliver 40–56 Gy in 8–16 fractions. Target coverage parameters (D90, Dmean, and V100) and dose uniformity (V110–200, D0.1cc, D1cc, and D2cc) were studied according to target depth (<5mm vs. ≥5mm) and applicator thickness (5–10mm vs. ≥10mm). Results: The average prescription depth was 4.2±1.5mm. The average bolus thickness was 9.2±2.4mm. The median CTV volume was 10.0 cc (0.2–212.4 cc). Similar target coverage was achieved with prescription depths of <5mm and ≥5mm (Dmean = 113.8% vs. 112.4% and D90 = 100.2% vs. 98.3%). The <5mm prescription depth plans were more uniform (D0.1cc = 131.8% vs. 151.8%). Bolus thickness <10mm vs. ≥10mm plans also had similar target coverage (Dmean = 118.2% vs. 110.7% and D90 = 100.1% vs. 99.0%). Applicators ≥10mm thick, however, provide more uniform target dosimetry (D0.1cc = 146.9% vs. 139.5%). Conclusion: Prescription depth is based upon the thickness of the lesion and upon the clinical needs of the patient. Applicators ≥10mm thick provide more dose uniformity than 5–10mm thick applicators. Applicator thickness is an important variable that should be considered during treatment planning to achieve optimal dose uniformity

  5. Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Hardev; De La Fuente Herman, Tania; Showalter, Barry; Thompson, Spencer J.; Syzek, Elizabeth J.; Herman, Terence; Ahmad, Salahuddin [Department of Radiation Oncology, Peggy and Charles Stephenson Oklahoma Cancer Center, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104 (United States)

    2012-10-23

    This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

  6. Role of vaginal pallor reaction in predicting late vaginal stenosis after high-dose-rate brachytherapy in treatment-naive patients with cervical cancer.

    Science.gov (United States)

    Yoshida, Ken; Yamazaki, Hideya; Nakamura, Satoaki; Masui, Koji; Kotsuma, Tadayuki; Akiyama, Hironori; Tanaka, Eiichi; Yoshikawa, Nobuhiko; Uesugi, Yasuo; Shimbo, Taiju; Narumi, Yoshifumi; Yoshioka, Yasuo

    2015-07-01

    To assess actual rates of late vaginal stenosis and identify predisposing factors for complications among patients with previously untreated cervical cancer following high-dose-rate brachytherapy. We performed longitudinal analyses of 57 patients using the modified Dische score at 6, 12, 18, 24, 36, and 60 months after treatment, which consisted of 15 interstitial brachytherapys and 42 conventional intracavitary brachytherapys, with a median follow-up time of 36 months (range, 6 to 144 months). More than half of the patients developed grade 1 (mild) vaginal stenosis within the first year of follow-up, and grade 2 (97.5%, moderate) to grade 3 (severe) stenosis gradually increased with time. Actual stenosis rates for grade 1, 2, and 3 were 97.5% (95% confidence interval [CI], 92.7 to 97.5), 60.7% (95% CI, 42.2 to 79.3), and 7.4% (95% CI, 0 to 18.4) at 3 years after treatment. Pallor reaction grade 2-3 at 6 months was only a statistically significant predisposing factor for grade 2-3 late vaginal stenosis 3 years or later with a hazard ratio of 3.48 (95% CI, 1.32 to 9.19; p=0.018) by a multivariate Cox proportional hazard model. Patients with grade 0-1 pallor reaction at 6 months showed a grade ≥2 vaginal stenosis rate of 53%, whereas the grade 2-3 pallor reaction group achieved a grade ≥2 vaginal stenosis rate at 3 years at 100% (p=0.001). High-dose-rate brachytherapy was associated with high incidence of late vaginal stenosis. Pallor reaction grade 2-3 at 6 months was predictive of late grade 2-3 vaginal stenosis at 3 years after treatment. These findings should prove helpful for patient counseling and preventive intervention.

  7. Accelerated partial breast irradiation: An analysis of variables associated with late toxicity and long-term cosmetic outcome after high-dose-rate interstitial brachytherapy

    International Nuclear Information System (INIS)

    Wazer, David E.; Kaufman, Seth; Cuttino, Laurie; Di Petrillo, Thomas; Arthur, Douglas W.

    2006-01-01

    Purpose: To perform a detailed analysis of variables associated with late tissue effects of high-dose-rate (HDR) interstitial brachytherapy accelerated partial breast irradiation (APBI) in a large cohort of patients with prolonged follow-up. Methods and Materials: Beginning in 1995, 75 women with Stage I/II breast cancer were enrolled in identical institutional trials evaluating APBI as monotherapy after lumpectomy. Patients eligible included those with T1-2, N0-1 (≤3 nodes positive), M0 tumors of nonlobular histology with negative surgical margins, no extracapsular nodal extension, and negative results on postexcision mammogram. All patients underwent surgical excision and postoperative irradiation with HDR interstitial brachytherapy. The planning target volume was defined as the excision cavity plus a 2-cm margin. Treatment was delivered with a high-activity Ir-192 source at 3.4 Gy per fraction twice daily for 5 days to a total dose of 34 Gy. Dosimetric analyses were performed with three-dimensional postimplant dose and volume reconstructions. All patients were evaluated at 3-6-month intervals and assessed with a standardized cosmetic rating scale and according to Radiation Therapy Oncology Group late normal tissue toxicity scoring criteria. Clinical and therapy-related features were analyzed for their relationship to cosmetic outcome and toxicity rating. Clinical features analyzed included age, volume of resection, history of diabetes or hypertension, extent of axillary surgery, and systemic therapies. Therapy-related features analyzed included volume of tissue encompassed by the 100%, 150%, and 200% isodose lines (V100, V150, and V200, respectively), the dose homogeneity index (DHI), number of source dwell positions, and planar separation. Results: The median follow-up of all patients was 73 months (range, 43-118 months). The cosmetic outcome at last follow-up was rated as excellent, good, and fair/poor in 67%, 24%, and 9% of patients, respectively

  8. Impact of age on quality of life in patients with localized prostate cancer treated with high-dose rate brachytherapy combined with external beam radiotherapy.

    Science.gov (United States)

    Kikkawa, Kazuro; Iba, Akinori; Kohjimoto, Yasuo; Noda, Yasutaka; Sonomura, Tetsuo; Hara, Isao

    2018-02-04

    To evaluate age-related quality of life changes in patients with localized prostate cancer treated by high-dose rate brachytherapy combined with external beam radiation therapy. A total of 172 patients with clinically localized prostate cancer were categorized to age groups <75 years and ≥75 years. Changes in their quality of life were evaluated using the Japanese version of Medical Outcome Study 8-Items Short Form Health Survey, Expanded Prostate Cancer Index Composite and International Index of Erectile Function-5 at baseline, and followed up to 24 months after treatment. There were no significant differences in Medical Outcome Study 8-Items Short Form Health Survey scores, and urinary and bowel scores of the Expanded Prostate Cancer Index Composite for older men after treatment. International Index of Erectile Function-5 summary scores were significantly decreased in both groups. Although sexual function and sexual bother scores were decreased in patients aged <75 years, these scores were maintained in patients aged ≥75 years. Quality of life of prostate cancer patients undergoing high-dose rate brachytherapy combined with external beam radiation therapy does not seem to be significantly affected by age. © 2018 The Japanese Urological Association.

  9. Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

    Science.gov (United States)

    Palmer, Antony; Bradley, David; Nisbet, Andrew

    2012-06-01

    This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification.

  10. A survey of quality control practices for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy in the United Kingdom

    Science.gov (United States)

    Bidmead, Margaret; Nisbet, Andrew

    2012-01-01

    Purpose A survey of quality control (QC) currently undertaken in UK radiotherapy centres for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy has been conducted. The purpose was to benchmark current accepted practice of tests, frequencies and tolerances to assure acceptable HDR/PDR equipment performance. It is 20 years since a similar survey was conducted in the UK and the current review is timed to coincide with a revision of the IPEM Report 81 guidelines for quality control in radiotherapy. Material and methods All radiotherapy centres in the UK were invited by email to complete a comprehensive questionnaire on their current brachytherapy QC practice, including: equipment type, patient workload, source calibration method, level of image guidance for planning, prescribing practices, QC tests, method used, staff involved, test frequencies, and acceptable tolerance limits. Results Survey data was acquired between June and August 2012. Of the 64 centres invited, 47 (73%) responded, with 31 centres having brachytherapy equipment (3 PDR) and fully completing the survey, 13 reporting no HDR/PDR brachytherapy, and 3 intending to commence HDR brachytherapy in the near future. All centres had comprehensive QC schedules in place and there was general agreement on key test frequencies and tolerances. Greatest discord was whether source strength for treatment planning should be derived from measurement, as at 58% of centres, or from the certified value, at 42%. IPEM Report 81 continues to be the most frequently cited source of QC guidance, followed by ESTRO Booklet No. 8. Conclusions A comprehensive survey of QC practices for HDR/PDR brachytherapy in UK has been conducted. This is a useful reference to which centres may benchmark their own practice. However, individuals should take a risk-assessment based approach, employing full knowledge of local equipment, clinical procedures and available test equipment in order to determine individual QC needs. PMID:23378853

  11. Outcomes of salvage high-dose-rate brachytherapy with or without external beam radiotherapy for isolated vaginal recurrence of endometrial cancer

    Directory of Open Access Journals (Sweden)

    Shuhei Sekii

    2017-05-01

    Full Text Available Purpose: This study was designed to retrospectively analyze outcomes of high-dose-rate (HDR brachytherapy, with or without external beam radiotherapy (EBRT, in patients with vaginal recurrence of endometrial carcinoma, and to identify factors prognostic of patient outcomes. Material and methods : The medical records of all patients who underwent HDR brachytherapy for initial recurrence in the vagina of endometrial cancer after definitive surgery between 1992 and 2014 were retrospectively reviewed. All patients underwent either intracavitary brachytherapy (ICBT or interstitial brachytherapy (ISBT with or without EBRT. Late toxicity was graded using the EORTC (LENT/SOMA scale, revised in 1995. Results : Thirty-seven patients were identified. The median follow-up time was 48 months (range: 6-225 months. Of these 37 patients, 23 underwent ICBT, 14 underwent ISBT, and 26 underwent EBRT. Tumor size at first examination of initial relapse was significantly larger in the ISBT than in the ICBT group. The 4-year respective overall survival (OS, local control (LC, and progression-free survival (PFS rates in the entire cohort were 81.0%, 77.9%, and 56.8%, respectively. The interval between diagnosis of first recurrence and radiotherapy (< 3 months, ≥ 3 months was a significant predictor of LC and PFS. OS and LC rates did not differ significantly in the ICBT and ISBT groups. Two patients experienced grade 2 rectal bleeding, and four experienced grade 2 hematuria. No grade 3 or higher late complications were observed. Conclusions : Salvage HDR brachytherapy is an optimal for treating vaginal recurrence of endometrial carcinoma with acceptable morbidity. Early radiotherapy, including brachytherapy, should be considered for women who experience vaginal recurrence of endometrial cancer.

  12. High-dose-rate Interstitial Brachytherapy Boost with a Pedicled Latissimus Dorsi Myocutaneous Flap for Myxofibrosarcoma of the Arm

    Directory of Open Access Journals (Sweden)

    Jordan D. Lane, BS

    2014-10-01

    Full Text Available Summary: A 71-year-old man was found to have a 7.4 × 2.9 × 7.0 cm myxofibrosarcoma of the right medial arm close to neurovascular structures. He received 50 Gray (Gy of preoperative external beam radiation. Radical resection resulted in a 15 × 10 cm defect. Nine brachytherapy catheters were placed, and a pedicled latissimus dorsi myocutaneous flap was used in reconstruction. Final pathology confirmed myxofibrosarcoma, high grade. The tumor was <1 mm from 2 margins. A total of 17.5 Gy of brachytherapy was delivered to the surgical bed from postoperative days 7 to 9. The flap developed fat necrosis distally which eventually required surgical debridement on postoperative day 58. It subsequently healed well and maintained good function of the limb. The patient remains under surveillance without evidence of recurrence.

  13. Polyethylene glycol hydrogel rectal spacer implantation in patients with prostate cancer undergoing combination high-dose-rate brachytherapy and external beam radiotherapy.

    Science.gov (United States)

    Yeh, Jekwon; Lehrich, Brandon; Tran, Carolyn; Mesa, Albert; Baghdassarian, Ruben; Yoshida, Jeffrey; Torrey, Robert; Gazzaniga, Michael; Weinberg, Alan; Chalfin, Stuart; Ravera, John; Tokita, Kenneth

    2016-01-01

    To present rectal toxicity rates in patients administered a polyethylene glycol (PEG) hydrogel rectal spacer in conjunction with combination high-dose-rate brachytherapy and external beam radiotherapy. Between February 2010 and April 2015, 326 prostate carcinoma patients underwent combination high-dose-rate brachytherapy of 16 Gy (average dose 15.5 Gy; standard deviation [SD] = 1.6 Gy) and external beam radiotherapy of 59.4 Gy (average dose 60.2 Gy; SD = 2.9 Gy). In conjunction with the radiation therapy regimen, each patient was injected with 10 mL of a PEG hydrogel in the anterior perirectal fat space. The injectable spacer (rectal spacer) creates a gap between the prostate and the rectum. The rectum is displaced from the radiation field, and rectal dose is substantially reduced. The goal is a reduction in rectal radiation toxicity. Clinical efficacy was determined by measuring acute and chronic rectal toxicity using the National Cancer Center Institute Common Terminology Criteria for Adverse Events v4.0 grading scheme. Median followup was 16 months. The mean anterior-posterior separation achieved was 1.6 cm (SD = 0.4 cm). Rates of acute Grade 1 and 2 rectal toxicity were 37.4% and 2.8%, respectively. There were no acute Grade 3/4 toxicities. Rates of late Grade 1, 2, and 3 rectal toxicity were 12.7%, 1.4%, and 0.7%, respectively. There were no late Grade 4 toxicities. PEG rectal spacer implantation is safe and well tolerated. Acute and chronic rectal toxicities are low despite aggressive dose escalation. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. Dosimetry of indigenously developed 192Ir high-dose rate brachytherapy source: An EGSnrc Monte Carlo study

    Directory of Open Access Journals (Sweden)

    Sridhar Sahoo

    2016-01-01

    Full Text Available Clinical application using high-dose rate (HDR 192Ir sources in remote afterloading technique is a well-established treatment method. In this direction, Board of Radiation and Isotope Technology (BRIT and Bhabha Atomic Research Centre, India, jointly indigenously developed a remote afterloading machine and 192Ir HDR source. The two-dimensional (2D dose distribution and dosimetric parameters of the BRIT 192Ir HDR source are generated using EGSnrc Monte Carlo code system in a 40 cm dia × 40 cm height cylindrical water phantom. The values of air-kerma strength and dose rate constant for BRIT 192Ir HDR source are 9.894 × 10−8 ± 0.06% UBq−1 and 1.112 ± 0.11% cGyh−1U−1, respectively. The values of radial dose function (gL(r of this source compare well with the corresponding values of BEBIG, Flexisource, and GammaMed 12i source models. This is because of identical active lengths of the sources (3.5 mm and the comparable phantom dimensions. A comparison of gL(r values of BRIT source with microSelectron-v1 show differences about 2% at r = 6 cm and up to 13% at r = 12 cm, which is due to differences in phantom dimensions involved in the calculations. The anisotropy function of BRIT 192Ir HDR source is comparable with the corresponding values of microSelectron-v1 (classic HDR source.

  15. An independent dose-to-point calculation program for the verification of high-dose-rate brachytherapy treatment planning

    International Nuclear Information System (INIS)

    Cohen, Gil'ad N.; Amols, Howard I.; Zaider, Marco

    2000-01-01

    Purpose: We describe computer software that performs, quickly and accurately, secondary dose calculations for high-dose-rate (HDR) treatment plans, including those employed for prostate treatments. Methods: The program takes as primary input the data file used by the HDR remote afterloader console for treatment. Dosimetric calculations are performed using the Meisberger polynomial and the anisotropy table for the HDR Iridium-192 source. For standard applicators, treatment geometry is automatically reconstructed and the dose is calculated at relevant reference point(s). Template-based treatment plans (e.g., prostate) require additional user input; the dose calculation is then performed at user-selected reference points. A total dwell time calculation for volume and planar implants using the Manchester tables was also implemented. Results: For fixed-geometry HDR procedures, secondary dose calculations are within 2% of the treatment plan, and results are available for review instantly. For more general applications, the calculated and planned doses are typically within 3% at the prescription isodose line. The Manchester-based dwell time calculation is within 10% of the planned time

  16. Comparative study of reference points by dosimetric analyses for late complications after uniform external radiotherapy and high-dose-rate brachytherapy for cervical cancer

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Yeh, L.-S.; Yang, S.-N.; Shiau, A.-C.; Lin, F.-J.

    2004-01-01

    Purpose: This study aimed to correlate and compare the predictive values of rectal and bladder reference doses of uniform external beam radiotherapy without shielding and high-dose-rate intracavitary brachytherapy (HDRICB) with late sequelae in patients with uterine cervical cancer. Methods and materials: Between September 1992 and December 1998, 154 patients who survived more than 12 months after treatment were studied. Initially, they were treated with 10-MV X-rays (44 to 45 Gy/22 to 25 fractions over 4 to 5 weeks) to the whole pelvis, after which HDRICB was performed using 192 Ir remote afterloading at 1-week intervals for 4 weeks. The standard prescribed dose for each HDRICB was 6.0 Gy to point A. Patient- and treatment-related-factors were evaluated for late rectal complications using logistic regression modeling. Results: The probability of rectal complications showed better correlation of dose-response with increasing total ICRU (International Committee on Radiotherapy Units and Measurements) rectal dose. Multivariate logistic regression demonstrated a high risk of late rectal sequelae in patients who developed rectal complications (p 0.0001;relative risk, 15.06;95% CI, 2.89∼43.7) and total ICRU rectal dose greater than 16 Gy (p = 0.02;relative risk, 2.07;95% CI, 1.13∼4.55). The high risk factors for bladder complications were seen in patients who developed rectal complications (p = 0.0001;relative risk, 15.2;95% CI, 2.81∼44.9) and total ICRU bladder dose greater than 24 Gy (p = 0.02;relative risk, 8.93;95% CI, 1.79∼33.1). Conclusion: This study demonstrated the predictive value of ICRU rectal and bladder reference dosing in HDRICB for patients receiving uniform external beam radiation therapy without central shielding. Patients who had a total ICRU rectal dose greater than 16 Gy, or a total ICRU bladder dose over 24 Gy, were at risk of late sequelae

  17. High-dose irradiation for prostate cancer via a high-dose-rate brachytherapy boost: Results of a phase I to II study

    International Nuclear Information System (INIS)

    Vargas, Carlos E.; Martinez, Alvaro A.; Boike, Thomas P.; Spencer, William; Goldstein, Neal; Gustafson, Gary S.; Krauss, Daniel J.; Gonzalez, Jose

    2006-01-01

    Objective: To evaluate outcomes of intermediate- and high-risk prostate cancer patients on a prospective dose-escalation study of pelvic external-beam radiation therapy (EBRT) combined with high-dose-rate (HDR) brachytherapy boost. Methods: From November 1991 to April 2003, 197 patients were treated for intermediate- and high-risk disease features. All patients had prostate-specific antigen >10 ng/ml, Gleason score ≥7, or clinical stage ≥T2b, and all received pelvic EBRT (46 Gy) while receiving either two or three HDR boost treatments. HDR dose fractionation increased progressively and was divided into two dose levels. The mean prostate biologic equivalency dose was 88.2 Gy for the low-dose group and 116.8 Gy for the high-dose group (α/β = 1.2). Clinical failure was either local failure or distant metastasis; clinical event-free survival (cEFS) was defined as patients who lived free of clinical failure. Results: Median follow-up was 4.9 years. The 5-year rates were as follows: biologic failure (BF), 18.6%, clinical failure (CF), 9.8%, cEFS 84.8%, cause-specific survival (CSS), 98.3%, and overall survival (OS), 92.9%. Five-year biochemical failure (68.7% vs. 86%, p < 0.001), CF (6.1% vs. 15.6%, p = 0.04), cEFS (75.5% vs. 91.7%, p = 0.003), CSS (95.4% vs. 100%, p = 0.02), and OS (86.2% vs. 97.8%, p = 0.002) were significantly better for the high-dose group. Multivariate analysis showed that high-dose group (p = 0.01, HR 0.35) and Gleason score (p = 0.01, HR 1.84) were significant variables for cEFS. Multivariate analysis showed that high-dose group (p = 0.01, HR 0.14) and age (p = 0.03, HR 1.09 per year) were significant variables for overall survival. Conclusion: There is a strong dose-response relationship for intermediate- to high-risk prostate cancer patients. Improved locoregional control with higher radiation doses alone can significantly decrease biochemical and clinical failures

  18. SU-E-T-579: Impact of Cylinder Size in High-Dose Rate Brachytherapy (HDRBT) for Primary Cancer in the Vagina

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H; Gopalakrishnan, M; Lee, P; Sathiaseelan, V [Department of Radiation Oncology, Northwestern Memorial Hospital, Chicago, IL (United States)

    2014-06-01

    Purpose: To evaluate the dosimetric impact of cylinder size in high dose rate Brachytherapy for primary vaginal cancers. Methods: Patients treated with HDR vaginal vault radiation in a list of cylinders ranging from 2.5 to 4 cm in diameter at 0.5 cm increment were analyzed. All patients’ doses were prescribed at the 0.5 cm from the vaginal surface with different treatment lengths. A series of reference points were created to optimize the dose distribution. The fraction dose was 5.5 Gy, the treatment was repeated for 4 times in two weeks. A cylinder volume was contoured in each case according to the prescribed treatment length, and then expanded to 5 mm to get a volume Cylinder-5mm-exp. A volume of PTV-Eval was obtained by subtracting the cylinder volume from the Cylinder-5mm-exp. The shell volume, PTV-Eval serves as the target volume for dosimetric evaluation. Results: DVH curves and average doses of PTV-Eval were obtained. Our results indicated that the DVH curves shifted toward higher dose side when larger cylinder was used instead of smaller ones. When 3.0 cm cylinder was used instead of 2.5 cm, for 3.0 cm treatment length, the average dose only increased 1%, from 790 to 799 cGy. However, the average doses for 3.5 and 4 cm cylinders respectively are 932 and 1137 cGy at the same treatment length. For 5.0 cm treatment length, the average dose is 741 cGy for 2.5 cm cylinder, and 859 cGy for 3 cm cylinder. Conclusion: Our data analysis suggests that for the vaginal intracavitary HDRBT, the average dose is at least 35% larger than the prescribed dose in the studied cases; the size of the cylinder will impact the dose delivered to the target volume. The cylinder with bigger diameter tends to deliver larger average dose to the PTV-Eval.

  19. Therapeutic analysis of high-dose-rate {sup 192}Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hualin, E-mail: hualin.zhang@northwestern.edu; Donnelly, Eric D.; Strauss, Jonathan B. [Department of Radiation Oncology, Robert H. Lurie Comprehensive Cancer Center, Northwestern University Feinberg School of Medicine, Northwestern Memorial Hospital, Chicago, Illinois 60611 (United States); Qi, Yujin [Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW 2522 (Australia)

    2016-01-15

    Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0){sup 4} to (13

  20. Therapeutic analysis of high-dose-rate 192Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions

    Science.gov (United States)

    Zhang, Hualin; Donnelly, Eric D.; Strauss, Jonathan B.; Qi, Yujin

    2016-01-01

    Purpose: To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. Methods: A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. Results: EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0)4 to (13.4)4 for the

  1. Therapeutic analysis of high-dose-rate (192)Ir vaginal cuff brachytherapy for endometrial cancer using a cylindrical target volume model and varied cancer cell distributions.

    Science.gov (United States)

    Zhang, Hualin; Donnelly, Eric D; Strauss, Jonathan B; Qi, Yujin

    2016-01-01

    To evaluate high-dose-rate (HDR) vaginal cuff brachytherapy (VCBT) in the treatment of endometrial cancer in a cylindrical target volume with either a varied or a constant cancer cell distributions using the linear quadratic (LQ) model. A Monte Carlo (MC) technique was used to calculate the 3D dose distribution of HDR VCBT over a variety of cylinder diameters and treatment lengths. A treatment planning system (TPS) was used to make plans for the various cylinder diameters, treatment lengths, and prescriptions using the clinical protocol. The dwell times obtained from the TPS were fed into MC. The LQ model was used to evaluate the therapeutic outcome of two brachytherapy regimens prescribed either at 0.5 cm depth (5.5 Gy × 4 fractions) or at the vaginal mucosal surface (8.8 Gy × 4 fractions) for the treatment of endometrial cancer. An experimentally determined endometrial cancer cell distribution, which showed a varied and resembled a half-Gaussian distribution, was used in radiobiology modeling. The equivalent uniform dose (EUD) to cancer cells was calculated for each treatment scenario. The therapeutic ratio (TR) was defined by comparing VCBT with a uniform dose radiotherapy plan in term of normal cell survival at the same level of cancer cell killing. Calculations of clinical impact were run twice assuming two different types of cancer cell density distributions in the cylindrical target volume: (1) a half-Gaussian or (2) a uniform distribution. EUDs were weakly dependent on cylinder size, treatment length, and the prescription depth, but strongly dependent on the cancer cell distribution. TRs were strongly dependent on the cylinder size, treatment length, types of the cancer cell distributions, and the sensitivity of normal tissue. With a half-Gaussian distribution of cancer cells which populated at the vaginal mucosa the most, the EUDs were between 6.9 Gy × 4 and 7.8 Gy × 4, the TRs were in the range from (5.0)(4) to (13.4)(4) for the radiosensitive normal

  2. Preventing Complications from High-Dose Rate Brachytherapy when Treating Mobile Tongue Cancer via the Application of a Modular Lead-Lined Spacer.

    Directory of Open Access Journals (Sweden)

    Shumei Murakami

    Full Text Available To point out the advantages and drawbacks of high-dose rate brachytherapy in the treatment of mobile tongue cancer and indicate the clinical importance of modular lead-lined spacers when applying this technique to patients.First, all basic steps to construct the modular spacer are shown. Second, we simulate and evaluate the dose rate reduction for a wide range of spacer configurations.With increasing distance to the source absorbed doses dropped considerably. Significantly more shielding was obtained when lead was added to the spacer and this effect was most pronounced on shorter (i.e. more clinically relevant distances to the source.The modular spacer represents an important addition to the planning and treatment stages of mobile tongue cancer using HDR-ISBT.

  3. WE-G-BRB-07: Application of RADPOS in Vivo Dosimetry for QA of High Dose Rate Brachytherapy.

    Science.gov (United States)

    Cherpak, A; Kertzscher, G; Cygler, J

    2012-06-01

    The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing for simultaneous online measurements of dose and spatial position. In this work, we assess the potential use of RADPOS for measurements of motion and dose during prostate HDR brachytherapy. The RADPOS was positioned in the centre of a thin plastic tube supported by two parallel acrylic plates submerged in water. The detector was calibrated by sending an Ir-192 source into an adjacent tube, to positions ranging from 8.0 to -8.0 cm along the vertical axis in increments of 0.5 cm. The dwell time at each position was 20 s and the change in threshold voltage of the RADPOS dosimeter was recorded for each position. The expected dose for each source position was calculated and compared to RADPOS measurements to obtain a detector calibration coefficient (cGy/mV). The procedure was then repeated sending the Ir-192 source into 5 other tubes, located 1 to 10 cm away from the RADPOS. Source positions, dwell times, and position of the RADPOS detector were the same as for the calibration. The dose for each source position was determined by RADPOS measurements and calibration coefficient and compared to the expected dose. An average calibration coefficient of 0.74±0.11 cGy/mV was calculated for RADPOS measurements of Ir-192 irradiations. The absolute difference between RADPOS values and expected dose for subsequent measurements averaged over all source positions was 0.7±5.4 cGy. In vivo dosimetry can potentially signal errors in catheter placement or numbering before entire dose is delivered. The demonstrated accuracy of RADPOS dose measurements and its ability to simultaneously measure displacement makes it a powerful tool for HDR brachytherapy treatments for prostate cancer, where high dose gradients and movement of the prostate gland can present unique in vivo dosimetry challenges. Financial and technical support has been received from Best Medical Canada and

  4. SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

  5. Preoperative radiotherapy with high dose rate brachytherapy in the treatment of stage IIB cervix cancer. A retrospective analysis of histological specimens

    International Nuclear Information System (INIS)

    Ferrigno, Robson; Trippe, N; Novaes, P.E.; Brandani, I.B.; Hanriot, R.; Souza, L.M.; Pellizzon, A.C.; Salvajoli, J.V.; Baraldi, H.E.; Maia, M.A.; Fogaroli, R.C.

    1996-01-01

    Purpose/Objective: To evaluate the histological specimens of the stage IIB cervix cancer patients who were treated by preoperative radiotherapy with external beam radiotherapy (EBRT) and high dose rate (HDR) brachytherapy. Materials and Methods: From August 1992 to August 1995, 32 patients with stage IIB cervix cancer were underwent to preoperative radiotherapy. All patients received EBRT at the whole pelvis with total dose of 45Gy in 25 fractions of 1,8Gy through a 4 MV linear accelerator. The HDR brachytherapy was realized through a Micro-Selectron device, working with Iridium-192 with initial activity of 10 Ci. The prescribed dose was 6,0Gy at point A, defined by the Manchester, system in 2 weekly insertions during the course of EBRT. The insertions were done by the Fletcher colpostats in association with intrauterine tandem. Four to six weeks after the end of radiotherapy, the patients were underwent to Total Hysterectomy and Salpingoforectomy through Piver second level technique. The uterine specimens were histologically analysed with attention to residual disease at the cervix and lymph nodes status. Results: The histological analysis showed that 19 (59,4%) patients had no residual tumor at the cervix while 13 (40,6%) had microscopic residual tumor. The lymph nodes were negative in 30 (93,8%) patients and positive in 2 (6,3%). All positive lymph nodes patients also had microscopic residual tumor at the cervix. With the follow up ranging from six to 42 months and medium of 21 months, 29 (90,6%) patients are alive with no evidence of disease, one (5,6%) is alive with local recurrence and two (6,2%) have died due to the progression of local disease. Of the 19 patients with negative specimens, 18 (94,7%) are alive with no evidence of disease and of the 13 patients with positive specimens, 11 (84,6%) are alive with no evidence of disease. Local recurrence occurred in two patients with positive specimens and in one with negative. These differences are not

  6. Workflow efficiency for the treatment planning process in CT-guided high-dose-rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Michaud, Anthony L; Benedict, Stanley; Montemayor, Eliseo; Hunt, Jon Paul; Wright, Cari; Mathai, Mathew; Mayadev, Jyoti S

    2016-01-01

    To investigate process efficiency, we present a prospective investigation of the treatment planning phase of image-guided brachytherapy (BT) for cervical cancer using a specific checklist. From October 2012 to January 2014, 76 BT procedures were consecutively performed. Prospective data on the CT-based treatment planning process was collected using a specific checklist which details the following steps: (1) dosimetry planning, (2) physician review start, (3) physician review time, (4) dosimetry processing, (5) physics review start, (6) physics review, and (7) procedural pause. Variables examined included the use of a pre-BT MRI, clinic duty conflicts, resident teaching, and the use of specific BT planners. Analysis was performed using descriptive statistics, t-test, and analysis of variance. Seventy-five prospectively gathered checklists comprised this analysis. The mean time for treatment planning was 95 minutes (med 94, std 18). The mean intervals in the above steps were (1) = 42, (2) = 5, (3) = 19, (4) = 10, (5) = 6, (6) = 13, and (7) = 26 minutes. There was no statistical difference in patients who had a pre-BT MRI. Resident teaching did not influence time, p = 0.17. Treatment planning time was decreased with a specific planner, p = 0.0015. A skillful team approach is required for treatment planning efficiency in image-guided BT. We have found that the specific BT planners can have a significant effect on the overall planning efficiency. We continue to examine clinical and workflow-related factors that will enhance our safety and workflow process with BT. Published by Elsevier Inc.

  7. Acute genitourinary toxicity after high-dose-rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Ito, Kazuto; Saitoh, Jun-ichi; Noda, Shin-ei; Harashima, Koichi; Sakurai, Hideyuki; Nakayama, Yuko; Yamamoto, Takumi; Suzuki, Kazuhiro; Nakano, Takashi; Niibe, Hideo

    2005-01-01

    Purpose: Several investigations have revealed that the α/β ratio for prostate cancer is atypically low, and that hypofractionation or high-dose-rate (HDR) brachytherapy regimens using appropriate radiation doses may be expected to yield tumor control and late sequelae rates that are better or at least as favorable as those achieved with conventional radiation therapy. In this setting, we attempted treating localized prostate cancer patients with HDR brachytherapy combined with hypofractionated external beam radiation therapy (EBRT). The purpose of this study was to evaluate the feasibility of using this approach, with special emphasis on the relationship between the severity of acute genitourinary (GU) toxicity and the urethral dose calculated from the dose-volume histogram (DVH) of HDR brachytherapy. Methods and Materials: Between September 2000 and December 2003, 70 patients with localized prostate cancer were treated by iridium-192 HDR brachytherapy combined with hypofractionated EBRT at the Gunma University Hospital. Hypofractionated EBRT was administered in fraction doses of 3 Gy, three times per week; a total dose of 51 Gy was delivered to the prostate gland and the seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography (TRUS)-guided HDR brachytherapy. The fraction size and the number of fractions in HDR brachytherapy were prospectively changed, whereas the total radiation dose for EBRT was fixed at 51 Gy. The fractionation in HDR brachytherapy was as follows: 5 Gy x 5, 7 Gy x 3, 9 Gy x 2, administered twice per day, although the biologic effective dose (BED) for HDR brachytherapy combined with EBRT, assuming that the α/β ratio is 3, was almost equal to 138 in each fractionation group. The planning target volume was defined as the prostate gland with 5-mm margin all around, and the planning was conducted based on

  8. Failure modes and effects analysis in image-guided high-dose-rate brachytherapy: Quality control optimization to reduce errors in treatment volume.

    Science.gov (United States)

    Wadi-Ramahi, Shada; Alnajjar, Waleed; Mahmood, Rana; Jastaniyah, Noha; Moftah, Belal

    2016-01-01

    Analyze the inputs which cause treatment to the wrong volume in high-dose-rate brachytherapy (HDRB), with emphasis on imaging role during implant, planning, and treatment verification. The end purpose is to compare our current practice to the findings of the study and apply changes where necessary. Failure mode and effects analysis was used to study the failure pathways for treating the wrong volume in HDRB. The role of imaging and personnel was emphasized, and subcategories were formed. A quality assurance procedure is proposed for each high-scoring failure mode (FM). Forty FMs were found that lead to treating the wrong volume. Of these, 73% were human failures, 20% were machine failures, and 7% were procedural/guideline failures. The use of imaging was found to resolve 85% of the FMs. We also noted that imaging processes were under used in current practice of HDRB especially in pretreatment verification. Twelve FMs (30%) scored the highest, and for each one of them, we propose clinical/practical solutions that could be applied to reduce the risk by increasing detectability. This work resulted in two conclusions: the role of imaging in improving failure detection and the emphasized role of human-based failures. The majority of FMs are human failures, and imaging increased the ability to detect 85% of all FMs. We proposed quality assurance practices for each high-scoring FM and have implemented some of them in our own practice. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  9. 3-D conformal treatment of prostate cancer to 74 Gy vs. high-dose-rate brachytherapy boost: A cross-sectional quality-of-life survey

    International Nuclear Information System (INIS)

    Vordermark, Dirk

    2006-01-01

    The effects of two modalities of dose-escalated radiotherapy on health-related quality of life (HRQOL) were compared. Forty-one consecutive patients were treated with a 3-D conformal (3-DC) boost to 74 Gy, and 43 with high-dose rate (HDR) brachytherapy boost (2x9 Gy), following 3-D conformal treatment to 46 Gy. Median age was 70 years in both groups, median initial PSA was 7.9 μg/l in 3-DC boost patients and 8.1 μg/l in HDR boost patients. Stage was 7 in 52% and 47%, respectively. HRQOL was assessed cross-sectionally using EORTC QLQ-C30 and organ-specific PR25 modules 3-32 (median 19) and 4-25 (median 14) months after treatment, respectively. Questionnaires were completed by 93% and 97% of patients, respectively. Diarrhea and insomnia scores were significantly increased in both groups. In the PR25 module, scores of 3-DC boost and HDR boost patients for urinary, bowel and treatment-related symptoms were similar. Among responders, 34% of 3-DC boost patients and 86% of HDR boost patients had severe erectile problems. Dose escalation in prostate cancer by either 3-DC boost to 74 Gy or HDR brachytherapy boost appears to result in similar HRQOL profiles

  10. 3-D conformal treatment of prostate cancer to 74 Gy vs. high-dose-rate brachytherapy boost: A cross-sectional quality-of-life survey

    Energy Technology Data Exchange (ETDEWEB)

    Vordermark, Dirk [Univ. of Wuerzburg (DE). Dept. of Radiation Oncology] (and others)

    2006-09-15

    The effects of two modalities of dose-escalated radiotherapy on health-related quality of life (HRQOL) were compared. Forty-one consecutive patients were treated with a 3-D conformal (3-DC) boost to 74 Gy, and 43 with high-dose rate (HDR) brachytherapy boost (2x9 Gy), following 3-D conformal treatment to 46 Gy. Median age was 70 years in both groups, median initial PSA was 7.9 {mu}g/l in 3-DC boost patients and 8.1 {mu}g/l in HDR boost patients. Stage was 7 in 52% and 47%, respectively. HRQOL was assessed cross-sectionally using EORTC QLQ-C30 and organ-specific PR25 modules 3-32 (median 19) and 4-25 (median 14) months after treatment, respectively. Questionnaires were completed by 93% and 97% of patients, respectively. Diarrhea and insomnia scores were significantly increased in both groups. In the PR25 module, scores of 3-DC boost and HDR boost patients for urinary, bowel and treatment-related symptoms were similar. Among responders, 34% of 3-DC boost patients and 86% of HDR boost patients had severe erectile problems. Dose escalation in prostate cancer by either 3-DC boost to 74 Gy or HDR brachytherapy boost appears to result in similar HRQOL profiles.

  11. SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    International Nuclear Information System (INIS)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X

    2016-01-01

    Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

  12. SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

  13. Time-driven activity-based costing of low-dose-rate and high-dose-rate brachytherapy for low-risk prostate cancer.

    Science.gov (United States)

    Ilg, Annette M; Laviana, Aaron A; Kamrava, Mitchell; Veruttipong, Darlene; Steinberg, Michael; Park, Sang-June; Burke, Michael A; Niedzwiecki, Douglas; Kupelian, Patrick A; Saigal, Christopher

    Cost estimates through traditional hospital accounting systems are often arbitrary and ambiguous. We used time-driven activity-based costing (TDABC) to determine the true cost of low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy for prostate cancer and demonstrate opportunities for cost containment at an academic referral center. We implemented TDABC for patients treated with I-125, preplanned LDR and computed tomography based HDR brachytherapy with two implants from initial consultation through 12-month followup. We constructed detailed process maps for provision of both HDR and LDR. Personnel, space, equipment, and material costs of each step were identified and used to derive capacity cost rates, defined as price per minute. Each capacity cost rate was then multiplied by the relevant process time and products were summed to determine total cost of care. The calculated cost to deliver HDR was greater than LDR by $2,668.86 ($9,538 vs. $6,869). The first and second HDR treatment day cost $3,999.67 and $3,955.67, whereas LDR was delivered on one treatment day and cost $3,887.55. The greatest overall cost driver for both LDR and HDR was personnel at 65.6% ($4,506.82) and 67.0% ($6,387.27) of the total cost. After personnel costs, disposable materials contributed the second most for LDR ($1,920.66, 28.0%) and for HDR ($2,295.94, 24.0%). With TDABC, the true costs to deliver LDR and HDR from the health system perspective were derived. Analysis by physicians and hospital administrators regarding the cost of care afforded redesign opportunities including delivering HDR as one implant. Our work underscores the need to assess clinical outcomes to understand the true difference in value between these modalities. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  14. TU-AB-201-06: Evaluation of Electromagnetically Guided High- Dose Rate Brachytherapy for Ablative Treatment of Lung Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Pinkham, D.W.; Shultz, D.; Loo, B.W.; Sung, A.; Diehn, M.; Fahimian, B.P. [Stanford University, Stanford, CA (United States)

    2015-06-15

    Purpose: The advent of electromagnetic navigation bronchoscopy has enabled minimally invasive access to peripheral lung tumors previously inaccessible by optical bronchoscopes. As an adjunct to Stereotactic Ablative Radiosurgery (SABR), implantation of HDR catheters can provide focal treatments for multiple metastases and sites of retreatments. The authors evaluate a procedure to deliver ablative doses via Electromagnetically-Guided HDR (EMG-HDR) to lung metastases, quantify the resulting dosimetry, and assess its role in the comprehensive treatment of lung cancer. Methods: A retrospective study was conducted on ten patients, who, from 2009 to 2011, received a hypo-fractionated SABR regimen with 6MV VMAT to lesions in various lobes ranging from 1.5 to 20 cc in volume. A CT visible pathway was delineated for EM guided placement of an HDR applicator (catheter) and dwell times were optimized to ensure at least 98% prescription dose coverage of the GTV. Normal tissue doses were calculated using inhomogeneity corrections via a grid-based Boltzmann solver (Acuros-BV-1.5.0). Results: With EMG-HDR, an average of 83% (+/−9% standard deviation) of each patient’s GTV received over 200% of the prescription dose, as compared to SABR where the patients received an average maximum dose of 125% (+/−5%). EMG-HDR enabled a 59% (+/−12%) decrease in the aorta maximum dose, a 63% (+/−26%) decrease in the spinal cord max dose, and 57% (+/−23%) and 70% (+/−17%) decreases in the volume of the body receiving over 50% and 25% of the prescription dose, respectively. Conclusion: EMG-HDR enables delivery of higher ablative doses to the GTV, while concurrently reducing surrounding normal tissue doses. The single catheter approach shown here is limited to targets smaller than 20 cc. As such, the technique enables ablation of small lesions and a potentially safe and effective retreatment option in situations where external beam utility is limited by normal tissue constraints.

  15. Comparison of absorbed dose in the cervix carcinoma therapy by brachytherapy of high dose rate using the conventional planning and Monte Carlo simulation

    International Nuclear Information System (INIS)

    Silva, Aneli Oliveira da

    2010-01-01

    This study aims to compare the doses received for patients submitted to brachytherapy High Dose Rate (HDR) brachytherapy, a method of treatment of the cervix carcinoma, performed in the planning system PLATO BPS with the doses obtained by Monte Carlo simulation using the radiation transport code MCNP 5 and one female anthropomorphic phantom based on voxel, the FAX. The implementation of HDR brachytherapy treatment for the cervix carcinoma consists of the insertion of an intrauterine probe and an intravaginal probe (ring or ovoid) and then two radiographs are obtained, anteroposterior (AP) and lateral (LAT) to confirm the position of the applicators in the patient and to allow the treatment planning and the determination of the absorbed dose at points of interest: rectum, bladder, sigmoid and point A, which corresponds anatomically to the crossings of the uterine arteries with ureters The absorbed doses obtained with the code MCNP 5, with the exception of the absorbed dose in the rectum and sigmoid for the simulation considering a point source of 192 Ir, are lower than the absorbed doses from PLATO BPS calculations because the MCNP 5 considers the chemical compositions and densities of FAX body, not considering the medium as water. When considering the Monte Carlo simulation for a source with dimensions equal to that used in the brachytherapy irradiator used in this study, the values of calculated absorbed dose to the bladder, to the rectum, to the right point A and to the left point A were respectively lower than those determined by the treatment planning system in 33.29, 5.01, 22.93 and 19.04%. These values are almost all larger than the maximum acceptable deviation between patient planned and administered doses (5 %). With regard to the rectum and bladder, which are organs that must be protected, the present results are in favor of the radiological protection of patients. The point A, that is on the isodose of 100%, used to tumor treatment, the results indicate

  16. The value of systematic contouring of the bowel for treatment plan optimization in image-guided cervical cancer high-dose-rate brachytherapy.

    Science.gov (United States)

    Damato, Antonio L; Buzurovic, Ivan; Bhagwat, Mandar S; Cormack, Robert A; Devlin, Phillip M; Friesen, Scott; Hansen, Jorgen; Lee, Larissa J; Manuel, Matthias M; Cho, Linda P; O'Farrell, Desmond; Viswanathan, Akila N

    To investigate the dose-volume histogram metrics and optimization results of the contoured bowel in cervical cancer brachytherapy. Treatment plans of cervical cancer patients treated with image-guided high dose rate were retrospectively analyzed with institutional review board approval. In addition to the clinical target volume, rectum, bladder, and sigmoid, the bowel was contoured at the time of planning (Group 1) or at the time of this analysis (Group 2). Thirty-two patients treated with 145 insertions were included. Before optimization, mean ± 1 standard deviation overall bowel minimum dose to the most irradiated 2 cm 3 volume of an organ (D 2cc ) was 67.8 Gy α/β3 ± 13.7 Gy α/β3 (Group 1: 72.6 ± 13.2 Gy α/β3 ; Group 2: 57.3 ± 8.0 Gy α/β3 ). Before optimization, one patient in Group 1 presented a bowel D 2cc metric exceeding 100 Gy α/β3 . After optimization, bowel D 2cc mean ± 1 standard deviation was 59.4 ± 6.7 Gy α/β3 (Group 1: 61.4 ± 6.0 Gy α/β3 , p bowel when bowel is present in the pelvis. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  17. Emergências em braquiterapia de alta taxa de dose: manual de conduta Radiology emergencies in high-dose rate brachytherapy: code of practice

    Directory of Open Access Journals (Sweden)

    Paulo José Cecilio

    2001-02-01

    Full Text Available É crescente o uso de alta taxa de dose em braquiterapia para tratamento do câncer. O número de pacientes tratados em relação ao número de equipamentos existentes no Brasil é muito grande, sendo constantes os fatores tempo e pressão na rotina de funcionamento. Por isso, é comum, até mesmo nos grandes serviços, a falta de uma reflexão mais cuidadosa voltada à resolução de situações de emergência. Este trabalho faz uma análise prática das situações de emergência mais freqüentes e propõe um manual de conduta básico quando erros impossibilitam o retorno da fonte radioativa ao cofre, causando possível irradiação adicional à paciente e ao "staff" em unidades remotas de braquiterapia. Sugerem-se treinamentos, cuidados adicionais e controle de qualidade como forma de minimizar doses indesejáveis, bem como atenuar transtornos causados nas situações de emergência.The use of high-dose rate brachytherapy for cancer treatment is increasing and the number of patients treated in Brazil is high, considering the number of existing equipments. However, the small number of equipments is a limiting factor that bring on a lot of pressure on the working routine. For this reason, a reevaluation of emergency procedures is not carried out in most centers. This paper describes the most frequent emergency situations and suggests a code of practice when errors do not allow the return of the radiation source to the shield and result in undesirable radiation exposure to the patient and staff in remote centers for brachytherapy. We suggest training, additional caution measures and quality control in order to minimize undesirable doses.

  18. A Prospective Longitudinal Clinical Trial Evaluating Quality of Life After Breast-Conserving Surgery and High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd A. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Deshields, Teresa L. [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Margenthaler, Julie A.; Cyr, Amy E. [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Naughton, Michael [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Aft, Rebecca [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Department of Surgery, John Cochran Veterans Hospital, St. Louis, Missouri (United States); Gillanders, William E.; Eberlein, Timothy [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Matesa, Melissa A.; Ochoa, Laura L. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Zoberi, Imran, E-mail: izoberi@radonc.wustl.edu [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States)

    2013-12-01

    Purpose: To prospectively examine quality of life (QOL) of patients with early stage breast cancer treated with accelerated partial breast irradiation (APBI) using high-dose-rate (HDR) interstitial brachytherapy. Methods and Materials: Between March 2004 and December 2008, 151 patients with early stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients included those with Tis-T2 tumors measuring ≤3 cm excised with negative surgical margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. QOL was measured using European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30, version 3.0, and QLQ-BR23 questionnaires. The QLQ-C30 and QLQ-BR23 questionnaires were evaluated during pretreatment and then at 6 to 8 weeks, 3 to 4 months, 6 to 8 months, and 1 and 2 years after treatment. Results: The median follow-up was 55 months. Breast symptom scores remained stable in the months after treatment, and they significantly improved 6 to 8 months after treatment. Scores for emotional functioning, social functioning, and future perspective showed significant improvement 2 years after treatment. Symptomatic fat necrosis was associated with several changes in QOL, including increased pain, breast symptoms, systemic treatment side effects, dyspnea, and fatigue, as well as decreased role functioning, emotional functioning, and social functioning. Conclusions: HDR multicatheter interstitial brachytherapy was well tolerated, with no significant detrimental effect on measured QOL scales/items through 2 years of follow-up. Compared to pretreatment scores, there was improvement in breast symptoms, emotional functioning, social functioning, and future perspective 2 years after treatment.

  19. Cosmetic Analysis Following Breast-Conserving Surgery and Adjuvant High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer: A Prospective Clinical Study

    International Nuclear Information System (INIS)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd; Margenthaler, Julie A.; Naughton, Michael; Aft, Rebecca; Gillanders, William E.; Eberlein, Timothy; Matesa, Melissa A.; Zoberi, Imran

    2013-01-01

    Purpose: To prospectively evaluate cosmetic outcomes in women treated with accelerated partial breast irradiation using high-dose-rate interstitial brachytherapy for early-stage breast cancer. Methods and Materials: Between 2004 and 2008, 151 patients with early-stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients had stage Tis-T2 tumors of ≤3 cm that were excised with negative margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. Both the patients and the treating radiation oncologist qualitatively rated cosmesis as excellent, good, fair, or poor over time and ascribed a cause for changes in cosmesis. Cosmetic outcome was evaluated quantitatively by percentage of breast retraction assessment (pBRA). Patients also reported their satisfaction with treatment over time. Results: Median follow-up was 55 months. The rates of excellent-to-good cosmesis reported by patients and the treating radiation oncologist were 92% and 97% pretreatment, 91% and 97% at 3 to 4 months' follow-up, 87% and 94% at 2 years, and 92% and 94% at 3 years, respectively. Breast infection and adjuvant chemotherapy were independent predictors of a fair-to-poor cosmetic outcome at 3 years. Compared to pretreatment pBRA (7.35), there was no significant change in pBRA over time. The volume receiving more than 150 Gy (V150) was the only significant predictor of pBRA. The majority of patients (86.6%) were completely satisfied with their treatment. Conclusions: Patients and the treating physician reported a high rate of excellent-to-good cosmetic outcomes at all follow-up time points. Acute breast infection and chemotherapy were associated with worse cosmetic outcomes. Multicatheter interstitial brachytherapy does not significantly change breast size as measured by pBRA

  20. SU-E-J-93: Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate

    Energy Technology Data Exchange (ETDEWEB)

    Aitkenhead, A; Hamlett, L; Wood, D; Choudhury, A [The Christie Hospital NHS Foundation Trust, Manchester, Greater Manchester (United Kingdom)

    2014-06-01

    Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall was identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature.

  1. SU-E-J-93: Parametrisation of Dose to the Mucosa of the Anterior Rectal Wall in Transrectal Ultrasound Guided High-Dose-Rate Brachytherapy of the Prostate

    International Nuclear Information System (INIS)

    Aitkenhead, A; Hamlett, L; Wood, D; Choudhury, A

    2014-01-01

    Purpose: In high-dose-rate (HDR) brachytherapy of the prostate, radiation is delivered from a number of radioactive sources which are inserted via catheter into the target volume. The rectal mucosa also receives dose during the treatment, which may lead to late toxicity effects. To allow possible links between rectal dose and toxicity to be investigated, suitable methods of parametrising the rectal dose are needed. Methods: During treatment of a series of 95 patients, anatomy and catheter locations were monitored by transrectal ultrasound, and target volume positions were contoured on the ultrasound scan by the therapist. The anterior rectal mucosal wall was identified by contouring the transrectal ultrasound balloon within the ultrasound scan. Source positions and dwell times, along with the dose delivered to the patient were computed using the Oncentra Prostate treatment planning system (TPS). Data for the series of patients were exported from the TPS in Dicom format, and a series of parametrisation methods were developed in a Matlab environment to assess the rectal dose. Results: Contours of the anterior rectal mucosa were voxelised within Matlab to allow the dose to the rectal mucosa to be analysed directly from the 3D dose grid. Dose parametrisations based on dose-surface (DSH) and dose-line (DLH) histograms were obtained. Both lateral and longitudinal extents of the mucosal dose were parametrised using dose-line histograms in the relevant directions. Conclusion: We have developed a series of dose parametrisations for quantifying the dose to the rectal mucosa during HDR prostate brachytherapy which are suitable for future studies investigating potential associations between mucosal dose and late toxicity effects. The geometry of the transrectal probe standardises the rectal anatomy, making this treatment technique particularly suited to studies of this nature

  2. Cosmetic Analysis Following Breast-Conserving Surgery and Adjuvant High-Dose-Rate Interstitial Brachytherapy for Early-Stage Breast Cancer: A Prospective Clinical Study

    Energy Technology Data Exchange (ETDEWEB)

    Garsa, Adam A.; Ferraro, Daniel J.; DeWees, Todd [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Margenthaler, Julie A. [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Naughton, Michael [Department of Medicine, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Aft, Rebecca [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Department of Surgery, John Cochran Veterans Hospital, St. Louis, Missouri (United States); Gillanders, William E.; Eberlein, Timothy [Department of Surgery, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Matesa, Melissa A. [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States); Zoberi, Imran, E-mail: izoberi@radonc.wustl.edu [Department of Radiation Oncology, Siteman Cancer Center, Barnes-Jewish Hospital and Washington University School of Medicine, St. Louis, Missouri (United States)

    2013-03-15

    Purpose: To prospectively evaluate cosmetic outcomes in women treated with accelerated partial breast irradiation using high-dose-rate interstitial brachytherapy for early-stage breast cancer. Methods and Materials: Between 2004 and 2008, 151 patients with early-stage breast cancer were enrolled in a phase 2 prospective clinical trial. Eligible patients had stage Tis-T2 tumors of ≤3 cm that were excised with negative margins and with no nodal involvement. Patients received 3.4 Gy twice daily to a total dose of 34 Gy. Both the patients and the treating radiation oncologist qualitatively rated cosmesis as excellent, good, fair, or poor over time and ascribed a cause for changes in cosmesis. Cosmetic outcome was evaluated quantitatively by percentage of breast retraction assessment (pBRA). Patients also reported their satisfaction with treatment over time. Results: Median follow-up was 55 months. The rates of excellent-to-good cosmesis reported by patients and the treating radiation oncologist were 92% and 97% pretreatment, 91% and 97% at 3 to 4 months' follow-up, 87% and 94% at 2 years, and 92% and 94% at 3 years, respectively. Breast infection and adjuvant chemotherapy were independent predictors of a fair-to-poor cosmetic outcome at 3 years. Compared to pretreatment pBRA (7.35), there was no significant change in pBRA over time. The volume receiving more than 150 Gy (V150) was the only significant predictor of pBRA. The majority of patients (86.6%) were completely satisfied with their treatment. Conclusions: Patients and the treating physician reported a high rate of excellent-to-good cosmetic outcomes at all follow-up time points. Acute breast infection and chemotherapy were associated with worse cosmetic outcomes. Multicatheter interstitial brachytherapy does not significantly change breast size as measured by pBRA.

  3. High-dose-rate intra-cavitary brachytherapy combined with external beam radiation therapy for under 40-year-old patients with invasive uterine cervical carcinoma. Clinical outcomes in 118 patients in a Japanese multi-institutional study, JASTRO

    International Nuclear Information System (INIS)

    Yamashita, Hideomi; Niibe, Yuzuru; Toita, Takafumi

    2013-01-01

    The current study was designed to evaluate the clinical outcomes of curative intent radiation therapy for young patients with invasive uterine cervical carcinoma in Japan. One hundred and eighteen patients aged ≤40 were registered in the multi-institutional study of the Japanese Society of Therapeutic Radiology and Oncology (JASTRO) from 26 major institutions in Japan. The age range was 24-39 years and the maximum tumor diameter was 2.0-9.2 cm. The International Federation of Gynecology and Obstetrics clinical stages were Ib, IIa, IIb, IIIa, IIIb and IVa in 17, 6, 40, 2, 50 and 3, respectively. Curative intent radiation therapy consisted of the combination of external beam radiation therapy and high-dose rate intra-cavitary brachytherapy. The total dose of external beam radiation therapy ranged between 44 and 68 Gy. Both the median and mode of total high-dose-rate intra-cavitary brachytherapy dose to point A were 24 Gy in four fractions. Ninety-six patients (58%) received chemotherapy. The 5-year overall survival rate and local control rate of all patients were 61 and 65%, respectively. The 5-year overall survival rates of International Federation of Gynecology and Obstetrics Stage Ib, IIa, IIb, IIIa, IIIb and IVa were 88, 100, 75, 100, 37 and 0%, respectively. The 5-year local control rates of International Federation of Gynecology and Obstetrics Stage Ib, IIa, IIb, IIIa, IIIb and IVa were 82, 75, 75, 100, 51 and 0%, respectively. Sixteen patients experienced grade 3 or greater late radiation morbidity. The 5-year overall survival rate of young patients with Stage IIIb was comparatively low at 37%. (author)

  4. An Internet-ready database for prospective randomized clinical trials of high-dose-rate brachytherapy for adenocarcinoma of the prostate

    International Nuclear Information System (INIS)

    Devlin, Phillip M.; Brus, Christina R.; Kazakin, Julia; Mitchell, Ronald B.; Demanes, D. Jeffrey; Edmundson, Gregory; Gribble, Michael; Gustafson, Gary S.; Kelly, Douglas A.; Linares, Luis A.; Martinez, Alvaro A.; Mate, Timothy P.; Nag, Subir; Perez, Carlos A.; Rao, Jaynath G.; Rodriguez, Rodney R.; Shasha, Daniel; Tripuraneni, Prabhakar

    2002-01-01

    Purpose: To demonstrate a new interactive Internet-ready database for prospective clinical trials in high-dose-rate (HDR) brachytherapy for prostate cancer. Methods and Materials: An Internet-ready database was created that allows common data acquisition and statistical analysis. Patient anonymity and confidentiality are preserved. These data forms include all common elements found from a survey of the databases. The forms allow the user to view patient data in a view-only or edit mode. Eight linked forms document patient data before and after receiving HDR therapy. The pretreatment forms are divided into four categories: staging, comorbid diseases, external beam radiotherapy data, and signs and symptoms. The posttreatment forms separate data by HDR implant information, HDR medications, posttreatment signs and symptoms, and follow-up data. The forms were tested for clinical usefulness. Conclusion: This Internet-based database enables the user to record and later analyze all relevant medical data and may become a reliable instrument for the follow-up of patients and evaluation of treatment results

  5. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  6. Effect of inhomogeneities and source position on dose distribution of nucletron high dose rate Ir-192 brachytherapy source by Monte Carlo simulation

    Directory of Open Access Journals (Sweden)

    Chandola R

    2010-01-01

    Full Text Available Background: The presence of least dense dry air and highly dense cortical bone in the path of radiation and the position of source, near or far from the surface of patient, affects the exact dose delivery like in breast brachytherapy. Aim: This study aims to find out the dose difference in the presence of inhomogenieties like cortical bone and dry air as well as to find out difference of dose due to position of source in water phantom of high dose rate (HDR 192 Ir nucletron microselectron v2 (mHDRv2 brachytherapy source using Monte Carlo (MC simulation EGSnrc code, so that the results could be used in Treatment Planning System (TPS for more precise brachytherapy treatment. Settings and Design: The settings and design are done using different software of the computer. Methods and Materials: For this study, the said source, water phantom of volume 30 x 30 x 30 cm 3 , inhomogeneities each of volume 1 x 2 x 2 cm 3 with their position, water of water phantom and position of source are modeled using three-dimensional MC EGSnrc code. Statistical Analysis Used: Mean and probability are used for results and discussion. Results : The % relative dose difference is calculated here as 5.5 to 6.5% higher and 4.5 to 5% lower in the presence of air and cortical bone respectively at transverse axis of the source, which may be due to difference of linear attenuation coefficients of the inhomogeneities. However, when the source was positioned at 1 cm distance from the surface of water phantom, the near points between 1 to 2 cm and 3 to 8 cm. from the source, at its transverse axis, were 2 to 3.5% and 4 to 16% underdose to the dose when the source was positioned at mid-point of water phantom. This may be due to lack of back scatter material when the source was positioned very near to the surface of said water phantom and overlap of the additional cause of missing scatter component with the primary dose for near points from the source. These results were found in

  7. Development and implementation of a remote audit tool for high dose rate (HDR) Ir-192 brachytherapy using optically stimulated luminescence dosimetry

    International Nuclear Information System (INIS)

    Casey, Kevin E.; Kry, Stephen F.; Howell, Rebecca M.; Followill, David; Alvarez, Paola; Lawyer, Ann

    2013-01-01

    Purpose: The aim of this work was to create a mailable phantom with measurement accuracy suitable for Radiological Physics Center (RPC) audits of high dose-rate (HDR) brachytherapy sources at institutions participating in National Cancer Institute-funded cooperative clinical trials. Optically stimulated luminescence dosimeters (OSLDs) were chosen as the dosimeter to be used with the phantom.Methods: The authors designed and built an 8 × 8 × 10 cm 3 prototype phantom that had two slots capable of holding Al 2 O 3 :C OSLDs (nanoDots; Landauer, Glenwood, IL) and a single channel capable of accepting all 192 Ir HDR brachytherapy sources in current clinical use in the United States. The authors irradiated the phantom with Nucletron and Varian 192 Ir HDR sources in order to determine correction factors for linearity with dose and the combined effects of irradiation energy and phantom characteristics. The phantom was then sent to eight institutions which volunteered to perform trial remote audits.Results: The linearity correction factor was k L = (−9.43 × 10 −5 × dose) + 1.009, where dose is in cGy, which differed from that determined by the RPC for the same batch of dosimeters using 60 Co irradiation. Separate block correction factors were determined for current versions of both Nucletron and Varian 192 Ir HDR sources and these vendor-specific correction factors differed by almost 2.6%. For the Nucletron source, the correction factor was 1.026 [95% confidence interval (CI) = 1.023–1.028], and for the Varian source, it was 1.000 (95% CI = 0.995–1.005). Variations in lateral source positioning up to 0.8 mm and distal/proximal source positioning up to 10 mm had minimal effect on dose measurement accuracy. The overall dose measurement uncertainty of the system was estimated to be 2.4% and 2.5% for the Nucletron and Varian sources, respectively (95% CI). This uncertainty was sufficient to establish a ±5% acceptance criterion for source strength audits under a

  8. Method of localization and implantation of the lumpectomy site for high dose rate brachytherapy after conservative surgery for T1 and T2 breast cancer

    International Nuclear Information System (INIS)

    Perera, F.; Chisela, F.; Engel, J.; Venkatesan, V.

    1995-01-01

    Purpose: This article describes our technique of localization and implantation of the lumpectomy site of patients with T1 and T2 breast cancer. Our method was developed as part of our Phase I/II pilot study of high dose rate (HDR) brachytherapy alone after conservative surgery for early breast cancer. Methods and Materials: In March 1992, we started a pilot study of HDR brachytherapy to the lumpectomy site as the sole radiotherapy after conservative surgery for clinical T1 or T2 invasive breast cancer. Initially, the protocol required intraoperative placement of the interstitial needles at the time of definitive surgery to the breast. The protocol was then generalized to allow the implantation of the lumpectomy site after definitive surgery to the breast, either at the time of subsequent axillary nodal dissection or postoperatively. To date, five patients have been implanted intraoperatively at the time of definitive breast surgery. Twelve patients were implanted after definitive breast surgery, with 7 patients being done at the time of axillary nodal dissection and 5 patients postoperatively. We devised a method of accurately localizing and implanting the lumpectomy site after definitive breast surgery. The method relies on the previous placement of surgical clips by the referring surgeon to mark the lumpectomy site. For each patient, a breast mold is made with radio-opaque angiocatheters taped onto the mold in the supero-inferior direction. A planning CT scan is then obtained through the lumpectomy site. The volume of the lumpectomy site, the number of implant planes necessary, and the orientation of the implants are then determined from the CT scan. The angiocatheters provide a reference grid on the CT films to locate the entry and exit points of the interstitial needles on the plastic mold. The entry and exit points for reference needles are then transferred onto the patient's skin enabling implantation of the lumpectomy site. Needle positions with respect to

  9. Verification of the calculation program for brachytherapy planning system of high dose rate (PLATO); Programa de verificacion del calculo para un sistema de planificacion de braquiterapia de alta tasa de dosis (PLATO)

    Energy Technology Data Exchange (ETDEWEB)

    Almansa, J.; Alaman, C.; Perez-Alija, J.; Herrero, C.; Real, R. del; Ososrio, J. L.

    2011-07-01

    In our treatments are performed brachytherapy high dose rate since 2007. The procedures performed include gynecological intracavitary treatment and interstitial. The treatments are performed with a source of Ir-192 activity between 5 and 10 Ci such that small variations in treatment times can cause damage to the patient. In addition the Royal Decree 1566/1998 on Quality Criteria in radiotherapy establishes the need to verify the monitor units or treatment time in radiotherapy and brachytherapy. All this justifies the existence of a redundant system for brachytherapy dose calculation that can reveal any abnormality is present.

  10. Braquiterapia endobrônquica de alta taxa de dose: estudo dosimétrico High dose-rate endobronchial brachytherapy: a dosimetric study

    Directory of Open Access Journals (Sweden)

    Regina Maria Godoy Lopes

    2010-02-01

    Full Text Available OBJETIVO: Avaliar a distribuição de dose em diferentes situações de braquiterapia endobrônquica de alta taxa de dose, com foco principalmente nos volumes de altas doses, e tentar definir situações de melhor ou pior distribuição de dose que possam servir de guia na prática clínica. MATERIAIS E MÉTODOS: Estudo teórico, simulando braquiterapia endobrônquica de alta taxa de dose utilizando dois cateteres, com variação da extensão de carregamento, angulação entre os cateteres, profundidade de cálculo e o intervalo entre as paradas da fonte. Com prescrição de 7,5 Gy, foram calculados os volumes englobados pelas isodoses correspondentes a 100%, 150% e 200% da dose prescrita (V100, V150 e V200, respectivamente e as razões V150/V100 e V200/V100. RESULTADOS: Os volumes aumentaram com o aumento da extensão de carregamento dos cateteres, profundidade de cálculo e angulação, com tendência a um aumento proporcionalmente menor para angulações maiores. As relações V150/V100 e V200/V100 foram, em geral, homogêneas, ao redor de 0,50 e 0,30, respectivamente. CONCLUSÃO: A distribuição de dose na situação considerada padrão é em geral adequada. Nenhum parâmetro específico que pudesse ser relacionado à maior toxicidade foi identificado. Recomendamos uma avaliação rápida da qualidade do implante por meio da análise das relações V150/V100 e V200/V100.OBJECTIVE: To evaluate the dose distribution in different situations of high dose-rate endobronchial brachytherapy, focusing especially on high-dose volumes, and try to identify better or worse situations in terms of dose distribution to aid as guidance in the clinical practice. MATERIALS AND METHODS: Theoretical study simulating high dose-rate endobronchial brachytherapy utilizing two catheters, varying the loading extent, angle between the catheters, prescription depth, and source step. With a prescription dose of 7.5 Gy, the volumes involved by the 100%, 150% and 200

  11. Promising Long-Term Health-Related Quality of Life After High-Dose-Rate Brachytherapy Boost for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Wahlgren, Thomas; Nilsson, Sten; Lennernaes, Bo; Brandberg, Yvonne

    2007-01-01

    Purpose: To explore the long-term general and disease-specific health-related quality of life (HRQOL) >5 years after combined radiotherapy for localized prostate cancer, including a high-dose-rate brachytherapy boost and hormonal deprivation therapy. Methods and Materials: Of 196 eligible patients with localized prostate cancer (Stage T1-T3a) consecutively treated with curative radiotherapy at our institution between June 1998 and August 2000, 182 (93%) completed the European Organization for Research and Treatment of Cancer Quality of Life questionnaires QLQ-C30 and QLQ-PR25, including specific questions on fecal incontinence >5 years after treatment in September 2005. A comparison with age-matched normative data was done, as well as a longitudinal analysis using HRQOL data from a previous study. Results: The analysis included 158 nonrecurrent patients. Comparisons made with normative data showed that physical and role functioning were significantly better statistically and social functioning was significantly worse. Diarrhea and sleep disturbances were more pronounced and pain less pronounced than in a normal male population. The longitudinal analysis of disease-specific HRQOL showed that urinary urgency and erectile problems persisted 5 years after treatment, and nocturia and hormonally dependent symptoms had declined significantly, with a statistically significant difference. Fecal incontinence was recognized by 25% of patients, of whom 80% considered it a minor problem. Conclusion: More than 5 years after combined radiotherapy, irritative urinary problems and erectile dysfunction remain concerns, although severe bowel disturbance and fecal incontinence seem to be minor problems. Longitudinally, a decline mainly in hormonally dependent symptoms was seen. Minor differences in general HRQOL compared with normative data were observed, possibly including 'response shift' effects

  12. SU-G-TeP2-10: Feasibility of Newly Designed Applicator for High Dose Rate Brachytherapy Treatment of Patients with Vaginal Vault Recurrence

    International Nuclear Information System (INIS)

    Lee, V; Wong, M; Chan, M; Cheung, S; Leung, R; Lee, K; Law, G; Tung, S; Huang, X; Chui, E; Leung, K; Kwong, D

    2016-01-01

    Purpose: To compare the dose of an in-house 3D-printed gynecology applicator (TMHGA) for vaginal vault recurrence of corpus cancer patients after operation for high dose rate brachytherapy treatment with commercially available applicators. Methods: A newly designed applicator is made from 3D-printing methods using ABSM30i. The isodose of the applicator is compared with Elekta multi-channel (MC) applicator and titanium Rotterdam applicator with coupling central tube and vaginal cylinder (RC). Three plans are created using three applicators in a CT set of water phantom. The applicators are anchored using the applicator library and implant library in the Elekta Oncentra treatment planning system (ver.4.5). The rectum is mimicked by creating a 2cm diameter cylinder, with a distance 1mm posteriorly away from the high risk CTV (HR-CTV). Similarly, the bladder is replicated by a 6cm diameter cylinder with distance 1mm anteriorly from the HR-CTV. Three plans are all normalized 1.5cm superior, 0.5cm anterior and 0.5cm posterior of the applicator surface. By fixing D90 of HR-CTV to 6Gy, the D2cc of rectum and bladder of three plans are compared. Results: The D2cc of the bladder for using TMHGA is lower than MC and RC by 14.0% and 11.9% respectively. While the D2cc of the rectum for using TMHGA is lower than MC and RC by 18.9% and 12.4% respectively. The total treatment time of TMHGA plan is shorter than MC and RC by 11.2% and 12.9%. Conclusion: The applicator created via 3D printing delivers a lower dose to the bladder and the rectum while keeping the same coverage to HR-CTV as other commercially available applicators. Additionally, the new applicator resulted in a reduction of treatment time, which is always welcome.

  13. SU-G-TeP2-10: Feasibility of Newly Designed Applicator for High Dose Rate Brachytherapy Treatment of Patients with Vaginal Vault Recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Lee, V; Wong, M; Chan, M; Cheung, S; Leung, R; Lee, K; Law, G; Tung, S [Tuen Mun Hospital (Hong Kong); Huang, X; Chui, E; Leung, K [The Chinese University of Hong Kong (Hong Kong); Kwong, D [The University of Hong Kong (Hong Kong)

    2016-06-15

    Purpose: To compare the dose of an in-house 3D-printed gynecology applicator (TMHGA) for vaginal vault recurrence of corpus cancer patients after operation for high dose rate brachytherapy treatment with commercially available applicators. Methods: A newly designed applicator is made from 3D-printing methods using ABSM30i. The isodose of the applicator is compared with Elekta multi-channel (MC) applicator and titanium Rotterdam applicator with coupling central tube and vaginal cylinder (RC). Three plans are created using three applicators in a CT set of water phantom. The applicators are anchored using the applicator library and implant library in the Elekta Oncentra treatment planning system (ver.4.5). The rectum is mimicked by creating a 2cm diameter cylinder, with a distance 1mm posteriorly away from the high risk CTV (HR-CTV). Similarly, the bladder is replicated by a 6cm diameter cylinder with distance 1mm anteriorly from the HR-CTV. Three plans are all normalized 1.5cm superior, 0.5cm anterior and 0.5cm posterior of the applicator surface. By fixing D90 of HR-CTV to 6Gy, the D2cc of rectum and bladder of three plans are compared. Results: The D2cc of the bladder for using TMHGA is lower than MC and RC by 14.0% and 11.9% respectively. While the D2cc of the rectum for using TMHGA is lower than MC and RC by 18.9% and 12.4% respectively. The total treatment time of TMHGA plan is shorter than MC and RC by 11.2% and 12.9%. Conclusion: The applicator created via 3D printing delivers a lower dose to the bladder and the rectum while keeping the same coverage to HR-CTV as other commercially available applicators. Additionally, the new applicator resulted in a reduction of treatment time, which is always welcome.

  14. SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C; Xing, L; Fahimian, B [Stanford University, Stanford, CA (United States)

    2016-06-15

    Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic

  15. Updated results of high-dose rate brachytherapy and external beam radiotherapy for locally and locally advanced prostate cancer using the RTOG-ASTRO phoenix definition

    Directory of Open Access Journals (Sweden)

    Antonio C. Pellizzon

    2008-06-01

    Full Text Available PURPOSE: To evaluate the prognostic factors for patients with local or locally advanced prostate cancer treated with external beam radiotherapy (RT and high dose rate brachytherapy (HDR according to the RTOG-ASTRO Phoenix Consensus Conference. MATERIALS AND METHODS: The charts of 209 patients treated between 1997 and 2005 with localized RT and HDR as a boost at the Department of Radiation Oncology, AC Camargo Hospital, Sao Paulo, Brazil were reviewed. Clinical and treatment parameters i.e.: patient's age, Gleason score, clinical stage, initial PSA (iPSA, risk group (RG for biochemical failure, doses of RT and HDR were evaluated. Median age and median follow-up time were 68 and 5.3 years, respectively. Median RT and HDR doses were 45 Gy and 20 Gy. RESULTS: Disease specific survival (DSS at 3.3 year was 94.2%. Regarding RG, for the LR (low risk, IR (intermediate risk and HR (high risk, the DSS rates at 3.3 years were 91.5%, 90.2% and 88.5%, respectively. On univariate analysis prognostic factors related to DSS were RG (p = 0.040, Gleason score ≤ 6 ng/mL (p = 0.002, total dose of HDR ≥ 20 Gy (p < 0.001 On multivariate analysis the only statistical significant predictive factor for biochemical control (bNED was the RG, p < 0.001 (CI - 1.147-3.561. CONCLUSIONS: Although the radiation dose administered to the prostate is an important factor related to bNED, this could not be established with statistical significance in this group of patients. To date , in our own experience, HDR associated to RT could be considered a successful approach in the treatment of prostate cancer.

  16. Geometrical sparing factors for the rectum and bladder in the prediction of grade 2 and higher complications after high-dose-rate brachytherapy for cervical cancer.

    Science.gov (United States)

    Chen, Shang-Wen; Liang, Ji-An; Hung, Yao-Ching; Yeh, Lian-Shung; Chang, Wei-Chun; Yang, Shih-Neng; Lin, Fang-Jen

    2009-12-01

    This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

  17. Geometrical Sparing Factors for the Rectum and Bladder in the Prediction of Grade 2 and Higher Complications After High-Dose-Rate Brachytherapy for Cervical Cancer

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Hung, Y.-C.; Yeh, L.-S.; Chang, W.-C.; Yang, S.-N.; Lin, F.-J.

    2009-01-01

    Purpose: This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. Methods: A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. Results: A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). Conclusion: This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

  18. Dose specification for 192Ir high dose rate brachytherapy in terms of dose-to-water-in-medium and dose-to-medium-in-medium

    International Nuclear Information System (INIS)

    Fonseca, Gabriel Paiva; Yoriyaz, Hélio; Tedgren, Åsa Carlsson; Nilsson, Josef; Persson, Maria; Reniers, Brigitte; Verhaegen, Frank

    2015-01-01

    Dose calculation in high dose rate brachytherapy with 192 Ir is usually based on the TG-43U1 protocol where all media are considered to be water. Several dose calculation algorithms have been developed that are capable of handling heterogeneities with two possibilities to report dose: dose-to-medium-in-medium (D m,m ) and dose-to-water-in-medium (D w,m ). The relation between D m,m and D w,m for 192 Ir is the main goal of this study, in particular the dependence of D w,m on the dose calculation approach using either large cavity theory (LCT) or small cavity theory (SCT). A head and neck case was selected due to the presence of media with a large range of atomic numbers relevant to tissues and mass densities such as air, soft tissues and bone interfaces. This case was simulated using a Monte Carlo (MC) code to score: D m,m, D w,m (LCT), mean photon energy and photon fluence. D w,m (SCT) was derived from MC simulations using the ratio between the unrestricted collisional stopping power of the actual medium and water. Differences between D m,m and D w,m (SCT or LCT) can be negligible (<1%) for some tissues e.g. muscle and significant for other tissues with differences of up to 14% for bone. Using SCT or LCT approaches leads to differences between D w,m (SCT) and D w,m (LCT) up to 29% for bone and 36% for teeth. The mean photon energy distribution ranges from 222 keV up to 356 keV. However, results obtained using mean photon energies are not equivalent to the ones obtained using the full, local photon spectrum. This work concludes that it is essential that brachytherapy studies clearly report the dose quantity. It further shows that while differences between D m,m and D w,m (SCT) mainly depend on tissue type, differences between D m,m and D w,m (LCT) are, in addition, significantly dependent on the local photon energy fluence spectrum which varies with distance to implanted sources. (paper)

  19. A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Showalter, Shayna L., E-mail: snl2t@virginia.edu [Division of Surgical Oncology, Department of Surgery, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Petroni, Gina [Division of Translation Research and Applied Statistics, Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Trifiletti, Daniel M.; Libby, Bruce [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Schroen, Anneke T.; Brenin, David R. [Division of Surgical Oncology, Department of Surgery, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Dalal, Parchayi [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Smolkin, Mark [Division of Translation Research and Applied Statistics, Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia (United States); Reardon, Kelli A.; Showalter, Timothy N. [Department of Radiation Oncology, University of Virginia School of Medicine, Charlottesville, Virginia (United States)

    2016-09-01

    Purpose: Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. Methods and Materials: A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Results: Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. Conclusions: CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial.

  20. The feasibility study and characterization of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Espinoza, A.; Beeksma, B.; Petasecca, M.; Fuduli, I.; Porumb, C.; Cutajar, D.; Lerch, M. L. F.; Rosenfeld, A. B.; Corde, S.; Jackson, M.

    2013-01-01

    Purpose: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly 192 Ir with an air KERMA strength range between 20 000 and 40 000 U, where 1 U = 1 μGy m 2 /h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named “magic phantom.”Methods: The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array “magic plate” (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the 192 Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a 192 Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ.Results: The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of

  1. High dose-rate brachytherapy as a treatment option in primary tracheal tumors Braquiterapia de alta taxa de dose como opção terapêutica nos tumores primários da traquéia

    Directory of Open Access Journals (Sweden)

    Heloisa de Andrade Carvalho

    2005-08-01

    Full Text Available PURPOSE: To present experience with high dose-rate endobronchial brachytherapy in the treatment of primary tracheal tumors. PATIENTS AND METHODS: Four patients with nonresected primary tracheal tumors are presented: 2 cases of squamous cell carcinoma of the trachea, 1 of recurrent adenoid cystic carcinoma, and 1 with recurrent plasmacytoma. All received brachytherapy, alone or as a boost for primary irradiation, in 3 or 4 fractions of 7.5 Gy, calculated at a depth of 1 cm. Follow-up was considered to start from the end of brachytherapy. RESULTS: Local control was achieved in all cases at the time of first bronchoscopic evaluation. Two patients with squamous cell carcinoma died at 6th and 33rd months after brachytherapy, respectively. The first had no evidence of disease, and the latter had local recurrence. The other 2 patients were alive after 64 and 110 months of follow-up, respectively, both with no evidence of disease. Tracheal stenosis developed in these 2 cases, 22 and 69 months after brachytherapy. Tracheal stent placement was needed only for the patient with an adenoid cystic carcinoma. CONCLUSIONS: Endobronchial high dose-rate brachytherapy may be used for tracheal tumors, even as a boost for external beam irradiation, or in recurrences. Local control in 3 out of 4 patients indicates that individual cases may benefit from the treatment. Long-term survival may also be expected, mainly for tumors with adenoid cystic histology.OBJETIVO: Apresentar a experiência do tratamento de 4 pacientes com tumores primários de traquéia, não operados, submetidos à braquiterapia endobrônquica de alta taxa de dose. PACIENTES E MÉTODOS: Dois casos de carcinoma espinocelular, uma recidiva de carcinoma adenóide cístico e uma recidiva de plasmocitoma primário da traquéia. Todos receberam braquiterapia endobrônquica, exclusiva ou como reforço de dose da radioterapia externa. Foram administradas 3 ou 4 frações de 7,5 Gy cada, calculados a 1 cm de

  2. Improve definition of titanium tandems in MR-guided high dose rate brachytherapy for cervical cancer using proton density weighted MRI

    International Nuclear Information System (INIS)

    Hu, Yanle; Esthappan, Jacqueline; Mutic, Sasa; Richardson, Susan; Gay, Hiram A; Schwarz, Julie K; Grigsby, Perry W

    2013-01-01

    For cervical cancer patients treated with MR-guided high dose rate brachytherapy, the accuracy of radiation delivery depends on accurate localization of both tumors and the applicator, e.g. tandem and ovoid. Standard T2-weighted (T2W) MRI has good tumor-tissue contrast. However, it suffers from poor uterus-tandem contrast, which makes the tandem delineation very challenging. In this study, we evaluated the possibility of using proton density weighted (PDW) MRI to improve the definition of titanium tandems. Both T2W and PDW MRI images were obtained from each cervical cancer patient. Imaging parameters were kept the same between the T2W and PDW sequences for each patient except the echo time (90 ms for T2W and 5.5 ms for PDW) and the slice thickness (0.5 cm for T2W and 0.25 cm for PDW). Uterus-tandem contrast was calculated by the equation C = (S u -S t )/S u , where S u and S t represented the average signal in the uterus and the tandem, respectively. The diameter of the tandem was measured 1.5 cm away from the tip of the tandem. The tandem was segmented by the histogram thresholding technique. PDW MRI could significantly improve the uterus-tandem contrast compared to T2W MRI (0.42±0.24 for T2W MRI, 0.77±0.14 for PDW MRI, p=0.0002). The average difference between the measured and physical diameters of the tandem was reduced from 0.20±0.15 cm by using T2W MRI to 0.10±0.11 cm by using PDW MRI (p=0.0003). The tandem segmented from the PDW image looked more uniform and complete compared to that from the T2W image. Compared to the standard T2W MRI, PDW MRI has better uterus-tandem contrast. The information provided by PDW MRI is complementary to those provided by T2W MRI. Therefore, we recommend adding PDW MRI to the simulation protocol to assist tandem delineation process for cervical cancer patients

  3. Electron and high-dose-rate brachytherapy boost in the conservative treatment of stage I-II breast cancer. First results of the randomized Budapest boost trial

    International Nuclear Information System (INIS)

    Polgar, C.; Fodor, J.; Orosz, Z.

    2002-01-01

    Background and Aims: To evaluate the effect of electron and high-dose-rate brachytherapy (HDR BT) boost on local tumor control (LTC), side effects and cosmesis after breast-conserving surgery (BCS) in a prospective randomized study. Patients and Methods: 207 women with stage I-II breast cancer who underwent BCS were treated by 50 Gy irradiation to the whole breast and then randomly assigned to receive either a boost to the tumor bed (n=104) or no further radiotherapy (n=103). Boost treatments consisted of either 16 Gy electron irradiation (n=52) or 12-14.25 Gy HDR BT (n=52). Breast cancer-related events, side effects, and cosmetic results were assessed. Results: At a median follow-up of 5.3 years, the crude rate of local recurrence was 6.7% (7/104) with and 15.5% (16/103) without boost. The 5-year probability of LTC, relapse-free survival (RFS), and cancer-specific survival (CSS) was 92.7% vs 84.9% (p=0.049), 76.6% vs 66.2% (p=0.044), and 90.4% vs. 82.1% (p=0.053), respectively. There was no significant difference in LTC between patients treated with electron or HDR BT boost (94.2% vs 91.4%; p=0.74). On multivariate analysis, patient age <40 years (RR: 4.53), positive margin status (RR: 4.17), and high mitotic activity index (RR: 3.60) were found to be significant risk factors for local recurrence. The incidence of grade 2-3 side effects was higher in the boost arm (17.3% vs 7.8%; p=0.03). However, the rate of excellent/good cosmetic results was similar for the two arms (85.6% vs 91.3%; p=0.14). Cosmesis was rated as excellent/good in 88.5% of patients treated with HDR BT and 82.7% of patients with electron boost (p=0.29). Conclusions: Boost dose significantly improves LTC and RFS in patients treated with BCS and radiotherapy. In spite of the higher incidence of late side effects in the boost arm, boost dose is strongly recommended for patients at high risk for local recurrence. Positive or close margin status, high mitotic activity index, and young patient age

  4. Magnetic Resonance Imaging (MRI) Markers for MRI-Guided High-Dose-Rate Brachytherapy: Novel Marker-Flange for Cervical Cancer and Marker Catheters for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Schindel, Joshua; Muruganandham, Manickam [Department of Radiation Oncology, University of Iowa, Iowa City, Iowa (United States); Pigge, F. Christopher [Department of Chemistry, University of Iowa, Iowa City, Iowa (United States); Anderson, James [Department of Radiation Oncology, University of Iowa, Iowa City, Iowa (United States); Kim, Yusung, E-mail: yusung-kim@uiowa.edu [Department of Radiation Oncology, University of Iowa, Iowa City, Iowa (United States)

    2013-06-01

    Purpose: To present a novel marker-flange, addressing source-reconstruction uncertainties due to the artifacts of a titanium intracavitary applicator used for magnetic resonance imaging (MRI)-guided high-dose-rate (HDR) brachytherapy (BT); and to evaluate 7 different MRI marker agents used for interstitial prostate BT and intracavitary gynecologic HDR BT when treatment plans are guided by MRI. Methods and Materials: Seven MRI marker agents were analyzed: saline solution, Conray-60, copper sulfate (CuSO{sub 4}) (1.5 g/L), liquid vitamin E, fish oil, 1% agarose gel (1 g agarose powder per 100 mL distilled water), and a cobalt–chloride complex contrast (C4) (CoCl{sub 2}/glycine = 4:1). A plastic, ring-shaped marker-flange was designed and tested on both titanium and plastic applicators. Three separate phantoms were designed to test the marker-flange, interstitial catheters for prostate BT, and intracavitary catheters for gynecologic HDR BT. T1- and T2-weighted MRI were analyzed for all markers in each phantom and quantified as percentages compared with a 3% agarose gel background. The geometric accuracy of the MR signal for the marker-flange was measured using an MRI-CT fusion. Results: The CuSO{sub 4} and C4 markers on T1-weighted MRI and saline on T2-weighted MRI showed the highest signals. The marker-flange showed hyper-signals of >500% with CuSO{sub 4} and C4 on T1-weighted MRI and of >400% with saline on T2-weighted MRI on titanium applicators. On T1-weighted MRI, the MRI signal inaccuracies of marker-flanges were measured <2 mm, regardless of marker agents, and that of CuSO{sub 4} was 0.42 ± 0.14 mm. Conclusion: The use of interstitial/intracavitary markers for MRI-guided prostate/gynecologic BT was observed to be feasible, providing accurate source pathway reconstruction. The novel marker-flange can produce extremely intense, accurate signals, demonstrating its feasibility for gynecologic HDR BT.

  5. The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

    International Nuclear Information System (INIS)

    Espinoza, A.; Petasecca, M.; Fuduli, I.; Lerch, M. L. F.; Rosenfeld, A. B.; Howie, A.; Bucci, J.; Corde, S.; Jackson, M.

    2015-01-01

    Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be

  6. The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza, A.; Petasecca, M.; Fuduli, I.; Lerch, M. L. F.; Rosenfeld, A. B., E-mail: anatoly@uow.edu.au [Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522 (Australia); Howie, A.; Bucci, J. [St George Hospital Cancer Care Centre, New South Wales 2217 (Australia); Corde, S.; Jackson, M. [Department of Radiation Oncology, Prince of Wales Hospital, New South Wales 2031 (Australia)

    2015-02-15

    Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named “magic phantom” (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. Methods: The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the “position–time gamma index,” was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. Results: For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position–time gamma index showed that all modifications made could be

  7. Characterization of TLD-100 in powders for dosimetric quality control of 192 Ir sources used in brachytherapy of high dose rate

    International Nuclear Information System (INIS)

    Loaiza C, S.P.

    2007-01-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D w for the energy of: 60 Co, 137C s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the 192 Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of 192 Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the 60 Co for D w , using a secondary standard ionization chamber PTW N30013 calibrated in D w by the National Research Council (NRC, Canada). AAPM TG-43 for D w in terms of the strength kerma Sk, calibrating this last one quantity for the 137 Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D w start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R TLD vs D w : For the energy of 60 Co, 137 Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F s ) for each energy corresponds to the slope of the CC, v. The F s for the two 192 Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of capsules were sent to two hospitals that have the HDR Brachytherapy with sources of 192

  8. A generic high-dose rate {sup 192}Ir brachytherapy source for evaluation of model-based dose calculations beyond the TG-43 formalism

    Energy Technology Data Exchange (ETDEWEB)

    Ballester, Facundo, E-mail: Facundo.Ballester@uv.es [Department of Atomic, Molecular and Nuclear Physics, University of Valencia, Burjassot 46100 (Spain); Carlsson Tedgren, Åsa [Department of Medical and Health Sciences (IMH), Radiation Physics, Faculty of Health Sciences, Linköping University, Linköping SE-581 85, Sweden and Department of Medical Physics, Karolinska University Hospital, Stockholm SE-171 76 (Sweden); Granero, Domingo [Department of Radiation Physics, ERESA, Hospital General Universitario, Valencia E-46014 (Spain); Haworth, Annette [Department of Physical Sciences, Peter MacCallum Cancer Centre and Royal Melbourne Institute of Technology, Melbourne, Victoria 3000 (Australia); Mourtada, Firas [Department of Radiation Oncology, Helen F. Graham Cancer Center, Christiana Care Health System, Newark, Delaware 19713 (United States); Fonseca, Gabriel Paiva [Instituto de Pesquisas Energéticas e Nucleares – IPEN-CNEN/SP, São Paulo 05508-000, Brazil and Department of Radiation Oncology (MAASTRO), GROW, School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Zourari, Kyveli; Papagiannis, Panagiotis [Medical Physics Laboratory, Medical School, University of Athens, 75 MikrasAsias, Athens 115 27 (Greece); Rivard, Mark J. [Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States); Siebert, Frank-André [Clinic of Radiotherapy, University Hospital of Schleswig-Holstein, Campus Kiel, Kiel 24105 (Germany); Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); and others

    2015-06-15

    Purpose: In order to facilitate a smooth transition for brachytherapy dose calculations from the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) formalism to model-based dose calculation algorithms (MBDCAs), treatment planning systems (TPSs) using a MBDCA require a set of well-defined test case plans characterized by Monte Carlo (MC) methods. This also permits direct dose comparison to TG-43 reference data. Such test case plans should be made available for use in the software commissioning process performed by clinical end users. To this end, a hypothetical, generic high-dose rate (HDR) {sup 192}Ir source and a virtual water phantom were designed, which can be imported into a TPS. Methods: A hypothetical, generic HDR {sup 192}Ir source was designed based on commercially available sources as well as a virtual, cubic water phantom that can be imported into any TPS in DICOM format. The dose distribution of the generic {sup 192}Ir source when placed at the center of the cubic phantom, and away from the center under altered scatter conditions, was evaluated using two commercial MBDCAs [Oncentra{sup ®} Brachy with advanced collapsed-cone engine (ACE) and BrachyVision ACUROS{sup TM}]. Dose comparisons were performed using state-of-the-art MC codes for radiation transport, including ALGEBRA, BrachyDose, GEANT4, MCNP5, MCNP6, and PENELOPE2008. The methodologies adhered to recommendations in the AAPM TG-229 report on high-energy brachytherapy source dosimetry. TG-43 dosimetry parameters, an along-away dose-rate table, and primary and scatter separated (PSS) data were obtained. The virtual water phantom of (201){sup 3} voxels (1 mm sides) was used to evaluate the calculated dose distributions. Two test case plans involving a single position of the generic HDR {sup 192}Ir source in this phantom were prepared: (i) source centered in the phantom and (ii) source displaced 7 cm laterally from the center. Datasets were independently produced by

  9. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.

    Science.gov (United States)

    Espinoza, A; Petasecca, M; Fuduli, I; Howie, A; Bucci, J; Corde, S; Jackson, M; Lerch, M L F; Rosenfeld, A B

    2015-02-01

    High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment deliveries can be challenging due to the high source activity utilized and the need for precise measurements of dwell positions and times. This paper describes the application of a novel phantom, based on a 2D 11 × 11 diode array detection system, named "magic phantom" (MPh), to accurately measure plan dwell positions and times, compare them directly to the treatment plan, determine errors in treatment delivery, and calculate absorbed dose. The magic phantom system was CT scanned and a 20 catheter plan was generated to simulate a nonspecific treatment scenario. This plan was delivered to the MPh and, using a custom developed software suite, the dwell positions and times were measured and compared to the plan. The original plan was also modified, with changes not disclosed to the primary authors, and measured again using the device and software to determine the modifications. A new metric, the "position-time gamma index," was developed to quantify the quality of a treatment delivery when compared to the treatment plan. The MPh was evaluated to determine the minimum measurable dwell time and step size. The incorporation of the TG-43U1 formalism directly into the software allows for dose calculations to be made based on the measured plan. The estimated dose distributions calculated by the software were compared to the treatment plan and to calibrated EBT3 film, using the 2D gamma analysis method. For the original plan, the magic phantom system was capable of measuring all dwell points and dwell times and the majority were found to be within 0.93 mm and 0.25 s, respectively, from the plan. By measuring the altered plan and comparing it to the unmodified treatment plan, the use of the position-time gamma index showed that all modifications made could be readily detected. The MPh was able to

  10. Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer; Avaliacao da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Jetro Pereira de [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Faculdade de Medicina; Rosa, Luiz Antonio Ribeiro da [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)], e-mail: lrosa@ird.gov.br; Batista, Delano Valdivino Santos; Bardella, Lucia Helena [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil). Unit of Medical Physics; Carvalho, Arnaldo Rangel [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. of Thermoluminescent Dosimetry

    2009-03-15

    Objective: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. Materials and methods: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg) which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. Results: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good agreement with the planned values based on two orthogonal (anteroposterior and lateral) radiographic images of the patients. Conclusion: The thermoluminescent dosimetric system developed in the present study is simple and easy to be utilized as compared to other rectal dosimetry methods. The system has shown to be effective in the evaluation of rectal doses in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. (author)

  11. SU-F-T-234: Quality Improvements in the Electronic Medical Record of Patients Treated with High Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Diener, T; Wilkinson, D

    2016-01-01

    Purpose: To improve workflow efficiency and patient safety by assessing the quality control documentation for HDR brachytherapy within our Electronic Medical Record System (Mosaiq). Methods: A list of parameters based on NRC regulations, our quality management program (QMP), recommendations of the ACR and the American Brachytherapy Society, and HDR treatment planning risks identified in our previous FMEA study was made. Next, the parameter entries were classified according to the type of data input—manual, electronic, or both. Manual entry included the electronic Brachytherapy Treatment Record (BTR) and pre-treatment Mosaiq Assessments list. Oncentra Treatment Reports (OTR) from the Oncentra Treatment Control System constituted the electronic data. The OTR includes a Pre-treatment Report for each fraction, and a Treatment Summary Report at the completion of treatment. Each entry was then examined for appropriateness and completeness of data; adjustments and additions as necessary were then made. Results: Ten out of twenty-one recorded treatment parameters were identified to be documented within both the BTR and OTR. Of these ten redundancies, eight were changed from recorded values to a simple checklist in the BTR to avoid recording errors. The other redundancies were kept in both documents due to their value to ensuring patient safety. An edit was made to the current BTR quality assessment; this change revises the definition of a medical event in accordance with ODH Regulation 3701:1-58-101. One addition was made to the current QMP documents regarding HDR. This addition requires a physician to be present through the duration of HDR treatment in accordance with ODH Regulation 3701:1-58-59; Paragraph (F); Section (2); Subsection (a). Conclusion: Careful examination of HDR documentation that originates from different sources can help to improve the accuracy and reliability of the documents. In addition, there may be a small improvement in efficiency due to

  12. SU-F-T-234: Quality Improvements in the Electronic Medical Record of Patients Treated with High Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Diener, T [Cleveland State University, Cleveland, OH (United States); Wilkinson, D [Cleveland Clinic Foundation, Cleveland, OH (United States)

    2016-06-15

    Purpose: To improve workflow efficiency and patient safety by assessing the quality control documentation for HDR brachytherapy within our Electronic Medical Record System (Mosaiq). Methods: A list of parameters based on NRC regulations, our quality management program (QMP), recommendations of the ACR and the American Brachytherapy Society, and HDR treatment planning risks identified in our previous FMEA study was made. Next, the parameter entries were classified according to the type of data input—manual, electronic, or both. Manual entry included the electronic Brachytherapy Treatment Record (BTR) and pre-treatment Mosaiq Assessments list. Oncentra Treatment Reports (OTR) from the Oncentra Treatment Control System constituted the electronic data. The OTR includes a Pre-treatment Report for each fraction, and a Treatment Summary Report at the completion of treatment. Each entry was then examined for appropriateness and completeness of data; adjustments and additions as necessary were then made. Results: Ten out of twenty-one recorded treatment parameters were identified to be documented within both the BTR and OTR. Of these ten redundancies, eight were changed from recorded values to a simple checklist in the BTR to avoid recording errors. The other redundancies were kept in both documents due to their value to ensuring patient safety. An edit was made to the current BTR quality assessment; this change revises the definition of a medical event in accordance with ODH Regulation 3701:1-58-101. One addition was made to the current QMP documents regarding HDR. This addition requires a physician to be present through the duration of HDR treatment in accordance with ODH Regulation 3701:1-58-59; Paragraph (F); Section (2); Subsection (a). Conclusion: Careful examination of HDR documentation that originates from different sources can help to improve the accuracy and reliability of the documents. In addition, there may be a small improvement in efficiency due to

  13. Pilot study in the treatment of endometrial carcinoma with 3D image-based high-dose-rate brachytherapy using modified Heyman packing: Clinical experience and dose-volume histogram analysis

    International Nuclear Information System (INIS)

    Weitmann, Hajo Dirk; Poetter, Richard; Waldhaeusl, Claudia; Nechvile, Elisabeth; Kirisits, Christian; Knocke, Tomas Hendrik

    2005-01-01

    Purpose: The aim of this study was to evaluate dose distribution within uterus (clinical target volume [CTV]) and tumor (gross tumor volume [GTV]) and the resulting clinical outcome based on systematic three-dimensional treatment planning with dose-volume adaptation. Dose-volume assessment and adaptation in organs at risk and its impact on side effects were investigated in parallel. Methods and Materials: Sixteen patients with either locally confined endometrial carcinoma (n = 15) or adenocarcinoma of uterus and ovaries after bilateral salpingo-oophorectomy (n = 1) were included. Heyman packing was performed with mean 11 Norman-Simon applicators (3-18). Three-dimensional treatment planning based on computed tomography (n = 29) or magnetic resonance imaging (n = 18) was done in all patients with contouring of CTV, GTV, and organs at risk. Dose-volume adaptation was achieved by dwell location and time variation (intensity modulation). Twelve patients treated with curative intent received five to seven fractions of high-dose-rate brachytherapy (7 Gy per fraction) corresponding to a total dose of 60 Gy (2 Gy per fraction and α/β of 10 Gy) to the CTV. Four patients had additional external beam radiotherapy (range, 10-40 Gy). One patient had salvage brachytherapy and 3 patients were treated with palliative intent. A dose-volume histogram analysis was performed in all patients. On average, 68% of the CTV and 92% of the GTV were encompassed by the 60 Gy reference volume. Median minimum dose to 90% of CTV and GTV (D90) was 35.3 Gy and 74 Gy, respectively. Results: All patients treated with curative intent had complete remission (12/12). After a median follow-up of 47 months, 5 patients are alive without tumor. Seven patients died without tumor from intercurrent disease after median 22 months. The patient with salvage treatment had a second local recurrence after 27 months and died of endometrial carcinoma after 57 months. In patients treated with palliative intent

  14. The Curie–Da Vinci Connection: 5-Years' Experience With Laparoscopic (Robot-Assisted) Implantation for High-Dose-Rate Brachytherapy of Solitary T2 Bladder Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Steen-Banasik, Elzbieta M. van der, E-mail: E.vanderSteen-Banasik@radiotherapiegroep.nl [Radiotherapiegroep, Arnhem (Netherlands); Smits, Geert A.H.J. [Department of Urology, Rijnstate Hospital, Arnhem (Netherlands); Oosterveld, Bernard J.; Janssen, Theo; Visser, Andries G. [Radiotherapiegroep, Arnhem (Netherlands)

    2016-08-01

    Purpose: To report experience and early results of laparoscopic implantation for interstitial brachytherapy (BT) of solitary bladder tumors and the feasibility of a high-dose-rate (HDR) schedule. Methods and Materials: From December 2009 to April 2015, 57 patients with a T2 solitary bladder tumor were treated in Arnhem with transurethral bladder resection followed by external beam irradiation, applied to the bladder and regional iliac lymph nodes, 40 Gy in 20 fractions, 5 fractions per week, and within 1 week interstitial HDR BT, in selected cases combined with partial cystectomy and lymph node dissection. The BT catheters were placed via a transabdominal approach with robotic assistance from a Da Vinci robot after a successful initial experience with a nonrobotic laparoscopic approach. The fraction schedule for HDR was 10 fractions of 2.5 Gy, 3 fractions per day. This was calculated to be equivalent to a reference low-dose-rate schedule of 30 Gy in 60 hours. Data for oncologic outcomes and toxicity (Common Toxicity Criteria version 4) were prospectively collected. Results: These modifications resulted in an average postoperative hospitalization of 6 days, minimal blood loss, and no wound healing problems. Two patients had severe acute toxicity: 1 pulmonary embolism grade 4 and 1 cardiac death. Late toxicity was mild (n=2 urogenital grade 3 toxicity). The median follow-up was 2 years. Using cumulative incidence competing risk analysis, the 2-year overall, disease-free, and disease-specific survival and local control rates were 59%, 71%, 87%, and 82%, respectively. Conclusions: The benefits of minimally invasive surgery for implantation of BT catheters and the feasibility of HDR BT in bladder cancer are documented. The patient outcome and adverse events are comparable to the best results published for a bladder-sparing approach.

  15. Rectal Bleeding After High-Dose-Rate Brachytherapy Combined With Hypofractionated External-Beam Radiotherapy for Localized Prostate Cancer: The Relationship Between Dose-Volume Histogram Parameters and the Occurrence Rate

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Masahiko, E-mail: masaoka@showa.gunma-u.ac.jp [Department of Radiation Oncology, Gunma University Graduate School of Medicine, Gunma (Japan); Ishikawa, Hitoshi; Ebara, Takeshi; Kato, Hiroyuki; Tamaki, Tomoaki [Department of Radiation Oncology, Gunma University Graduate School of Medicine, Gunma (Japan); Akimoto, Tetsuo [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan); Ito, Kazuto; Miyakubo, Mai; Yamamoto, Takumi; Suzuki, Kazuhiro [Department of Urology, Gunma University Graduate School of Medicine, Gunma (Japan); Takahashi, Takeo; Nakano, Takashi [Department of Radiation Oncology, Gunma University Graduate School of Medicine, Gunma (Japan)

    2012-02-01

    Purpose: To determine the predictive risk factors for Grade 2 or worse rectal bleeding after high-dose-rate brachytherapy (HDR-BT) combined with hypofractionated external-beam radiotherapy (EBRT) for prostate cancer using dose-volume histogram analysis. Methods and Materials: The records of 216 patients treated with HDR-BT combined with EBRT were analyzed. The treatment protocols for HDR-BT were 5 Gy Multiplication-Sign five times in 3 days or 7 Gy Multiplication-Sign three, 10.5 Gy Multiplication-Sign two, or 9 Gy Multiplication-Sign two in 2 days. The EBRT doses ranged from 45 to 51 Gy with a fractional dose of 3 Gy. Results: In 20 patients Grade 2 or worse rectal bleeding developed, and the cumulative incidence rate was 9% at 5 years. By converting the HDR-BT and EBRT radiation doses into biologic effective doses (BED), the BED{sub 3} at rectal volumes of 5% and 10% in the patients who experienced bleeding were significantly higher than those in the remaining 196 patients. Univariate analysis showed that a higher rectal BED{sub 3-5%} and the use of fewer needles in brachytherapy were correlated with the incidence of bleeding, but BED{sub 3-5%} was found to be the only significant factor on multivariate analysis. Conclusions: The radiation dose delivered to small rectal lesions as 5% is important for predicting Grade 2 or worse rectal bleeding after HDR-BT combined with EBRT for prostate cancer.

  16. Comparison of 2D and 3D Imaging and Treatment Planning for Postoperative Vaginal Apex High-Dose Rate Brachytherapy for Endometrial Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Russo, James K. [Department of Radiation Oncology, Hollings Cancer Center, Medical University of South Carolina, Charleston, South Carolina (United States); Armeson, Kent E. [Division of Biostatistics and Epidemiology, Hollings Cancer Center, Medical University of South Carolina, Charleston, South Carolina (United States); Richardson, Susan, E-mail: srichardson@radonc.wustl.edu [Department of Radiation Oncology, Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri (United States)

    2012-05-01

    Purpose: To evaluate bladder and rectal doses using two-dimensional (2D) and 3D treatment planning for vaginal cuff high-dose rate (HDR) in endometrial cancer. Methods and Materials: Ninety-one consecutive patients treated between 2000 and 2007 were evaluated. Seventy-one and 20 patients underwent 2D and 3D planning, respectively. Each patient received six fractions prescribed at 0.5 cm to the superior 3 cm of the vagina. International Commission on Radiation Units and Measurements (ICRU) doses were calculated for 2D patients. Maximum and 2-cc doses were calculated for 3D patients. Organ doses were normalized to prescription dose. Results: Bladder maximum doses were 178% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were no different than ICRU doses (p = 0.22). Two-cubic centimeter doses were 59% of maximum doses (p < 0.0001). Rectal maximum doses were 137% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were 87% of ICRU doses (p < 0.0001). Two-cubic centimeter doses were 64% of maximum doses (p < 0.0001). Using the first 1, 2, 3, 4 or 5 fractions, we predicted the final bladder dose to within 10% for 44%, 59%, 83%, 82%, and 89% of patients by using the ICRU dose, and for 45%, 55%, 80%, 85%, and 85% of patients by using the maximum dose, and for 37%, 68%, 79%, 79%, and 84% of patients by using the 2-cc dose. Using the first 1, 2, 3, 4 or 5 fractions, we predicted the final rectal dose to within 10% for 100%, 100%, 100%, 100%, and 100% of patients by using the ICRU dose, and for 60%, 65%, 70%, 75%, and 75% of patients by using the maximum dose, and for 68%, 95%, 84%, 84%, and 84% of patients by using the 2-cc dose. Conclusions: Doses to organs at risk vary depending on the calculation method. In some cases, final dose accuracy appears to plateau after the third fraction, indicating that simulation and planning may not be necessary in all fractions. A clinically relevant level of accuracy should be determined and further research conducted to address

  17. Dose volume histogram analysis of normal structures associated with accelerated partial breast irradiation delivered by high dose rate brachytherapy and comparison with whole breast external beam radiotherapy fields

    Directory of Open Access Journals (Sweden)

    Mutyala Subhakar

    2008-11-01

    Full Text Available Abstract Purpose To assess the radiation dose delivered to the heart and ipsilateral lung during accelerated partial breast brachytherapy using a MammoSite™ applicator and compare to those produced by whole breast external beam radiotherapy (WBRT. Materials and methods Dosimetric analysis was conducted on patients receiving MammoSite breast brachytherapy following conservative surgery for invasive ductal carcinoma. Cardiac dose was evaluated for patients with left breast tumors with a CT scan encompassing the entire heart. Lung dose was evaluated for patients in whom the entire lung was scanned. The prescription dose of 3400 cGy was 1 cm from the balloon surface. MammoSite dosimetry was compared to simulated WBRT fields with and without radiobiological correction for the effects of dose and fractionation. Dose parameters such as the volume of the structure receiving 10 Gy or more (V10 and the dose received by 20 cc of the structure (D20, were calculated as well as the maximum and mean doses received. Results Fifteen patients were studied, five had complete lung data and six had left-sided tumors with complete cardiac data. Ipsilateral lung volumes ranged from 925–1380 cc. Cardiac volumes ranged from 337–551 cc. MammoSite resulted in a significantly lower percentage lung V30 and lung and cardiac V20 than the WBRT fields, with and without radiobiological correction. Conclusion This study gives low values for incidental radiation received by the heart and ipsilateral lung using the MammoSite applicator. The volume of heart and lung irradiated to clinically significant levels was significantly lower with the MammoSite applicator than using simulated WBRT fields of the same CT data sets. Trial registration Dana Farber Trial Registry number 03-179

  18. Dose-volume analysis of target volume and critical structures in computed tomography image-based multicatheter high-dose-rate interstitial brachytherapy for head and neck cancer

    Directory of Open Access Journals (Sweden)

    Hironori Akiyama

    2017-12-01

    Full Text Available Purpose : To evaluate dose-volume relationships of target volume and critical structures in computed tomography (CT image-based brachytherapy for head and neck cancer. Material and methods : Thirty-seven patients with mobile tongue, floor of mouth, and base of tongue cancer treated with brachytherapy (post-operative alone and as a boost after external beam radiotherapy [EBRT], or definitive alone or as a boost after EBRT were selected. Treatment plans were made using post-implant CT images. The fractionation schedule was 7-15 × 3-5 Gy for post-operative (with or without EBRT, 14-15 × 3 Gy for definitive alone, and 5-10 × 3 Gy for boost treatments. For the target volume, V 100 , D 90 , and dose non-uniformity ratio (DNR were calculated. For the mandible, spinal cord and salivary glands doses to specified volumes were reported. Results : The median values of V 100 and D 90 were 89.9% and 99.9%, respectively; the median values of DNR was 0.46. The median D 2cm 3 of the mandible and spinal cord were 48.3% and 5.8%, respectively. The ipsilateral median D 2cm 3 of parotid and submandibular glands were 6.4% and 12.5%, whereas on the contralateral side, the corresponding values were 5.3% and 7.0%, respectively. Conclusions : Using conformal treatment planning, it was desirable to keep the dose to the mandible, spinal cord, and salivary glands at an acceptable level. The quantitative plan evaluation may help us find correlations between dosimetric parameters and clinical outcome, which may lead to improve the quality of the treatment, but it requires longer follow-up and results from other studies.

  19. Dosimetric Considerations to Determine the Optimal Technique for Localized Prostate Cancer Among External Photon, Proton, or Carbon-Ion Therapy and High-Dose-Rate or Low-Dose-Rate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Georg, Dietmar, E-mail: Dietmar.Georg@akhwien.at [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Hopfgartner, Johannes [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Gòra, Joanna [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Kuess, Peter [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Kragl, Gabriele [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Berger, Daniel [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Hegazy, Neamat [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Goldner, Gregor; Georg, Petra [Department of Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria); Christian Doppler Laboratory for Medical Radiation Research for Radiation Oncology, Medical University of Vienna/Allgemeines Krankenhaus der Stadt Wien, Vienna (Austria)

    2014-03-01

    Purpose: To assess the dosimetric differences among volumetric modulated arc therapy (VMAT), scanned proton therapy (intensity-modulated proton therapy, IMPT), scanned carbon-ion therapy (intensity-modulated carbon-ion therapy, IMIT), and low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy (BT) treatment of localized prostate cancer. Methods and Materials: Ten patients were considered for this planning study. For external beam radiation therapy (EBRT), planning target volume was created by adding a margin of 5 mm (lateral/anterior–posterior) and 8 mm (superior–inferior) to the clinical target volume. Bladder wall (BW), rectal wall (RW), femoral heads, urethra, and pelvic tissue were considered as organs at risk. For VMAT and IMPT, 78 Gy(relative biological effectiveness, RBE)/2 Gy were prescribed. The IMIT was based on 66 Gy(RBE)/20 fractions. The clinical target volume planning aims for HDR-BT ({sup 192}Ir) and LDR-BT ({sup 125}I) were D{sub 90%} ≥34 Gy in 8.5 Gy per fraction and D{sub 90%} ≥145 Gy. Both physical and RBE-weighted dose distributions for protons and carbon-ions were converted to dose distributions based on 2-Gy(IsoE) fractions. From these dose distributions various dose and dose–volume parameters were extracted. Results: Rectal wall exposure 30-70 Gy(IsoE) was reduced for IMIT, LDR-BT, and HDR-BT when compared with VMAT and IMPT. The high-dose region of the BW dose–volume histogram above 50 Gy(IsoE) of IMPT resembled the VMAT shape, whereas all other techniques showed a significantly lower high-dose region. For all 3 EBRT techniques similar urethra D{sub mean} around 74 Gy(IsoE) were obtained. The LDR-BT results were approximately 30 Gy(IsoE) higher, HDR-BT 10 Gy(IsoE) lower. Normal tissue and femoral head sparing was best with BT. Conclusion: Despite the different EBRT prescription and fractionation schemes, the high-dose regions of BW and RW expressed in Gy(IsoE) were on the same order of magnitude. Brachytherapy techniques

  20. Dosimetric Considerations to Determine the Optimal Technique for Localized Prostate Cancer Among External Photon, Proton, or Carbon-Ion Therapy and High-Dose-Rate or Low-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Georg, Dietmar; Hopfgartner, Johannes; Gòra, Joanna; Kuess, Peter; Kragl, Gabriele; Berger, Daniel; Hegazy, Neamat; Goldner, Gregor; Georg, Petra

    2014-01-01

    Purpose: To assess the dosimetric differences among volumetric modulated arc therapy (VMAT), scanned proton therapy (intensity-modulated proton therapy, IMPT), scanned carbon-ion therapy (intensity-modulated carbon-ion therapy, IMIT), and low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy (BT) treatment of localized prostate cancer. Methods and Materials: Ten patients were considered for this planning study. For external beam radiation therapy (EBRT), planning target volume was created by adding a margin of 5 mm (lateral/anterior–posterior) and 8 mm (superior–inferior) to the clinical target volume. Bladder wall (BW), rectal wall (RW), femoral heads, urethra, and pelvic tissue were considered as organs at risk. For VMAT and IMPT, 78 Gy(relative biological effectiveness, RBE)/2 Gy were prescribed. The IMIT was based on 66 Gy(RBE)/20 fractions. The clinical target volume planning aims for HDR-BT ( 192 Ir) and LDR-BT ( 125 I) were D 90% ≥34 Gy in 8.5 Gy per fraction and D 90% ≥145 Gy. Both physical and RBE-weighted dose distributions for protons and carbon-ions were converted to dose distributions based on 2-Gy(IsoE) fractions. From these dose distributions various dose and dose–volume parameters were extracted. Results: Rectal wall exposure 30-70 Gy(IsoE) was reduced for IMIT, LDR-BT, and HDR-BT when compared with VMAT and IMPT. The high-dose region of the BW dose–volume histogram above 50 Gy(IsoE) of IMPT resembled the VMAT shape, whereas all other techniques showed a significantly lower high-dose region. For all 3 EBRT techniques similar urethra D mean around 74 Gy(IsoE) were obtained. The LDR-BT results were approximately 30 Gy(IsoE) higher, HDR-BT 10 Gy(IsoE) lower. Normal tissue and femoral head sparing was best with BT. Conclusion: Despite the different EBRT prescription and fractionation schemes, the high-dose regions of BW and RW expressed in Gy(IsoE) were on the same order of magnitude. Brachytherapy techniques were clearly superior in

  1. Acute and late vaginal toxicity after adjuvant high-dose-rate vaginal brachytherapy in patients with intermediate risk endometrial cancer: is local therapy with hyaluronic acid of clinical benefit?

    Science.gov (United States)

    Delishaj, Durim; Fabrini, Maria Grazia; Gonnelli, Alessandra; Morganti, Riccardo; Perrone, Franco; Tana, Roberta; Paiar, Fabiola; Gadducci, Angiolo

    2016-01-01

    Purpose The aim of the present study was to evaluate the effectiveness of hyaluronic acid (HA) in the prevention of acute and late vaginal toxicities after high-dose-rate (HDR) vaginal brachytherapy (BT). Material and methods Between January 2011 and January 2015, we retrospectively analyzed 126 patients with endometrial cancer who underwent extrafascial hysterectomy with or without lymphadenectomy and adjuvant HDR-vaginal BT +/– adjuvant chemotherapy. The total dose prescription was 21 Gy in 3 fractions (one fraction for week). Vaginal ovules containing 5 mg of HA were given for whole duration of vaginal BT and for the two following weeks. Acute and late toxicities were evaluated according to CTCAE vs 4.02. Results According to the revised FIGO 2009 classification, most tumors were in stage IA (30.9%) and in stage IB (57.9%). Thirty-three patients (26.2%) received adjuvant chemotherapy before vaginal BT. Five-year disease-free survival (DFS) and five-year overall survival (OS) were 88% and 93%, respectively. The most common grade 1-2 acute toxicities were vaginal inflammation (18 patients, 14.3%) and dyspareunia (7 patients, 5.5%). Two patients (1.6%) had more than one toxicity. Late toxicity occurred in 20 patients (15.9%). Grade 1-2 late toxicities were fibrosis (14 patients, 11.1%) and telangiectasias (7 patients, 5.5%). Six patients (4.8%) had more than one late toxicity. No grade 3 or higher acute or late toxicities were observed. Conclusions These results appear to suggest that the local therapy with HA is of clinical benefit for intermediate risk endometrial cancer patients who receive adjuvant HDR-vaginal BT after surgery. A randomized trial comparing HA treatment vs. no local treatment in this clinical setting is warranted to further evaluate the efficacy of HA in preventing vaginal BT-related vaginal toxicity. PMID:28115957

  2. Evaluation of failure modes of computerized planning phase of interstitial implants with high dose rate brachytherapy using HFMEA; Avaliacao dos modos de falha do planejamento computadorizado em implantes intersticiais com braquiterapia de alta taxa de dose usando HFMEA

    Energy Technology Data Exchange (ETDEWEB)

    Biazotto, Bruna; Tokarski, Marcio, E-mail: bruna@ceb.unicamp.br [Universidade Estadual de Campinas (UNICAMP), SP (Brazil). Centro de Engenharia Biomedica

    2014-08-15

    This paper evaluates the failure modes of the computerized planning step in interstitial implants with high dose rate brachytherapy. The prospective tool of risk management Health Care Failure Mode and Effects Analysis (HFMEA) was used. Twelve subprocesses were identified, and 33 failure modes of which 21 justified new safety actions, and 9 of them were intolerable risks. The method proved itself useful in identifying failure modes, but laborious and subjective in their assessment. The main risks were due to human factors, which require training and commitment of management to their mitigation. (author)

  3. Concurrent weekly cisplatin plus external beam radiotherapy and high-dose rate brachytherapy for advanced cervical cancer: A control cohort comparison with radiation alone on treatment outcome and complications

    International Nuclear Information System (INIS)

    Chen, S.-W.; Liang, J.-A.; Hung, Y.-C.; Yeh, L.-S.; Chang, W.-C.; Lin, W.-C.; Yang, S.-N.; Lin, F.-J.

    2006-01-01

    Purpose: To test, though a control-cohort study, the hypothesis that concurrent chemoradiotherapy (CCRT) using weekly cisplatin, plus high-dose rate intracavitary brachytherapy (HDRICB) is superior to radiation (RT) alone in patients with advanced cervical cancer. Methods and Materials: A total of 171 patients with Stage IIB-III cervical cancer were enrolled in this study. Seventy patients were treated with CCRT and the results were compared with those of 101 patients who had been treated with RT using the same protocol at an early period. RT consisted of 45 Gy in 25 fractions to the whole pelvis, followed by a 12.6-Gy boost to the parametrium. Four courses of HDRICB using 6.0 Gy to Point A were performed. Chemotherapy consisted of weekly cisplatin at a dose of 40 mg/m 2 for 5-6 cycles. Results: The 4-year actuarial survival was 74% for the CCRT group and 68% for the RT group (p = 0.60). The 4-year pelvic relapse-free survival was 87% for the CCRT group and 85% for the RT group (p = 0.37). The 4-year distant metastases-free survival was 75% for the CCRT group and 76% for the RT group (p = 0.44). The cumulative incidence of gastrointestinal and genitourinary injuries of grade 3 or above was 14.3% for the CCRT group and 7.9% for the RT group (p = 0.19). Conclusion: This study did not show a survival benefit of CCRT with weekly cisplatin and HDRICB for Stage II-III cervical cancer, nor did it demonstrate a significant increase of late complications when comparing with RT alone

  4. Reporting and validation of gynaecological Groupe Euopeen de Curietherapie European Society for Therapeutic Radiology and Oncology (ESTRO) brachytherapy recommendations for MR image-based dose volume parameters and clinical outcome with high dose-rate brachytherapy in cervical cancers: a single-institution initial experience.

    Science.gov (United States)

    Mahantshetty, Umesh; Swamidas, Jamema; Khanna, Nehal; Engineer, Reena; Merchant, Nikhil H; Deshpande, Deepak D; Shrivastava, Shyamkishore

    2011-08-01

    The objectives are to report the dosimetric analysis, preliminary clinical outcome, and comparison with published data of 3-dimensional magnetic resonance-based high dose rate brachytherapy (BT) in cervical cancer. The data set of 24 patients with cervical cancer treated with high dose-rate brachytherapy applications was analyzed. All patients received radiation with or without chemotherapy (10 patients received concomitant chemoradiation). Point A, International Commission on Radiation Units and Measurement (ICRU) point doses, and Groupe Europeen de Curietherapie-European Society for Therapeutic Radiology and Oncology dose volume parameters, namely, high-risk clinical target volume (HR-CTV), D90 and D100 doses, and dose to D0.1cc and D2cc, for rectum, bladder, and sigmoid, were calculated and correlated. Mean ± SD HR-CTV was 45.2 ± 15.8 cc. The mean ± SD point A dose was 73.4 ± 4.5 Gy (median, 74.3 Gy) total biologically equivalent dose in 2 Gy per fraction (EQD2), whereas mean ± SD D90 doses were 70.9 ± 10.6 GyEQD2 (median, 68). The mean ± SD ICRU rectal and bladder points were 63.5 ± 8.1 and 80.4 ± 34.4 GyEQD2, respectively. The D0.1cc and D2cc for rectum were 66.0 ± 9.9 GyEQD2 (median, 64.5) and 57.8 ± 7.7 GyEQD2 (median, 58.8), for bladder 139.1 ± 54.7 GyEQD2 (median, 131.9) and 93.4 ± 24.6 GyEQD2 (median, 91), and sigmoid were 109.4 ± 45.2 GyEQD2 (median, 91) and 74.6 ± 19.6 GyEQD2 (median, 69.6). With a median follow-up of 24 months, 3 patients had local nodal failure, 1 had right external iliac nodal failure, and 1 had left supraclavicular nodal failure. The 3-D magnetic resonance image-based high dose-rate brachytherapy approach in cervical cancers is feasible. In our experience, the HR-CTV volumes are large, and D0.1cc and D2cc doses to bladder and sigmoid are higher than published literature so far.

  5. Prospective Multi-Institutional Study of Definitive Radiotherapy With High-Dose-Rate Intracavitary Brachytherapy in Patients With Nonbulky (<4-cm) Stage I and II Uterine Cervical Cancer (JAROG0401/JROSG04-2)

    Energy Technology Data Exchange (ETDEWEB)

    Toita, Takafumi, E-mail: b983255@med.u-ryukyu.ac.jp [Department of Radiology, Graduate School of Medical Science, University of Ryukyus, Okinawa (Japan); Kato, Shingo [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan); Niibe, Yuzuru [Department of Radiology, School of Medicine, Kitasato University, Sagamihara (Japan); Ohno, Tatsuya [Gunma University Heavy Ion Medical Center, Maebashi (Japan); Kazumoto, Tomoko [Department of Radiology, Saitama Cancer Center, Saitama (Japan); Kodaira, Takeshi [Department of Radiation Oncology, Aichi Cancer Center, Nagoya (Japan); Kataoka, Masaaki [Department of Radiology, National Shikoku Cancer Center, Ehime (Japan); Shikama, Naoto [Department of Radiation Oncology, Saku Central Hospital, Saku (Japan); Kenjo, Masahiro [Department of Radiation Oncology, Graduate School of Medical Science, Hiroshima University, Hiroshima (Japan); Tokumaru, Sunao [Department of Radiology, Saga University, Saga (Japan); Yamauchi, Chikako [Department of Radiation Oncology, Shiga Medical Center for Adults, Moriyama (Japan); Suzuki, Osamu [Department of Radiation Oncology, Osaka Medical Center for Cancer, Osaka (Japan); Sakurai, Hideyuki [Proton Medical Research Center and Tsukuba University, Tsukuba (Japan); Numasaki, Hodaka; Teshima, Teruki [Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Suita, Osaka (Japan); Oguchi, Masahiko [Department of Radiation Oncology, Cancer Institute Hospital, Tokyo (Japan); Kagami, Yoshikazu [Radiation Oncology Division, National Cancer Center Hospital, Tokyo (Japan); Nakano, Takashi [Department of Radiation Oncology, Gunma University, Graduate School of Medicine, Maebashi (Japan); Hiraoka, Masahiro [Department of Radiation Oncology and Image-applied Therapy, Kyoto University, Graduate School of Medicine, Kyoto (Japan); Mitsuhashi, Norio [Department of Radiation Oncology, Tokyo Women' s Medical University, Tokyo (Japan)

    2012-01-01

    Purpose: To determine the efficacy of a definitive radiotherapy protocol using high-dose-rate intracavitary brachytherapy (HDR-ICBT) with a low cumulative dose schedule in nonbulky early-stage cervical cancer patients, we conducted a prospective multi-institutional study. Methods and Materials: Eligible patients had squamous cell carcinoma of the intact uterine cervix, Federation of Gynecologic Oncology and Obstetrics (FIGO) stages Ib1, IIa, and IIb, tumor size <40 mm in diameter (assessed by T2-weighted magnetic resonance imaging), and no pelvic/para-aortic lymphadenopathy. The treatment protocol consisted of whole-pelvis external beam radiotherapy (EBRT) of 20 Gy/10 fractions, pelvic EBRT with midline block of 30 Gy/15 fractions, and HDR-ICBT of 24 Gy/4 fractions (at point A). The cumulative biologically effective dose (BED) was 62 Gy{sub 10} ({alpha}/{beta} = 10) at point A. The primary endpoint was the 2-year pelvic disease progression-free (PDPF) rate. All patients received a radiotherapy quality assurance review. Results: Between September 2004 and July 2007, 60 eligible patients were enrolled. Thirty-six patients were assessed with FIGO stage Ib1; 12 patients with stage IIa; and 12 patients with stage IIb. Median tumor diameter was 28 mm (range, 6-39 mm). Median overall treatment time was 43 days. Median follow-up was 49 months (range, 7-72 months). Seven patients developed recurrences: 3 patients had pelvic recurrences (2 central, 1 nodal), and 4 patients had distant metastases. The 2-year PDPF was 96% (95% confidence interval [CI], 92%-100%). The 2-year disease-free and overall survival rates were 90% (95% CI, 82%-98%) and 95% (95% CI, 89%-100%), respectively. The 2-year late complication rates (according to Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer of Grade {>=}1) were 18% (95% CI, 8%-28%) for large intestine/rectum, 4% (95% CI, 0%-8%) for small intestine, and 0% for bladder. No Grade {>=}3 cases were

  6. Prostate Specific Antigen (PSA) as Predicting Marker for Clinical Outcome and Evaluation of Early Toxicity Rate after High-Dose Rate Brachytherapy (HDR-BT) in Combination with Additional External Beam Radiation Therapy (EBRT) for High Risk Prostate Cancer.

    Science.gov (United States)

    Ecke, Thorsten H; Huang-Tiel, Hui-Juan; Golka, Klaus; Selinski, Silvia; Geis, Berit Christine; Koswig, Stephan; Bathe, Katrin; Hallmann, Steffen; Gerullis, Holger

    2016-11-10

    High-dose-rate brachytherapy (HDR-BT) with external beam radiation therapy (EBRT) is a common treatment option for locally advanced prostate cancer (PCa). Seventy-nine male patients (median age 71 years, range 50 to 79) with high-risk PCa underwent HDR-BT following EBRT between December 2009 and January 2016 with a median follow-up of 21 months. HDR-BT was administered in two treatment sessions (one week interval) with 9 Gy per fraction using a planning system and the Ir192 treatment unit GammaMed Plus iX. EBRT was performed with CT-based 3D-conformal treatment planning with a total dose administration of 50.4 Gy with 1.8 Gy per fraction and five fractions per week. Follow-up for all patients was organized one, three, and five years after radiation therapy to evaluate early and late toxicity side effects, metastases, local recurrence, and prostate-specific antigen (PSA) value measured in ng/mL. The evaluated data included age, PSA at time of diagnosis, PSA density, BMI (body mass index), Gleason score, D'Amico risk classification for PCa, digital rectal examination (DRE), PSA value after one/three/five year(s) follow-up (FU), time of follow-up, TNM classification, prostate volume, and early toxicity rates. Early toxicity rates were 8.86% for gastrointestinal, and 6.33% for genitourinary side effects. Of all treated patients, 84.81% had no side effects. All reported complications in early toxicity were grade 1. PSA density at time of diagnosis ( p = 0.009), PSA on date of first HDR-BT ( p = 0.033), and PSA on date of first follow-up after one year ( p = 0.025) have statistical significance on a higher risk to get a local recurrence during follow-up. HDR-BT in combination with additional EBRT in the presented design for high-risk PCa results in high biochemical control rates with minimal side-effects. PSA is a negative predictive biomarker for local recurrence during follow-up. A longer follow-up is needed to assess long-term outcome and toxicities.

  7. Bladder accumulated dose in image-guided high-dose-rate brachytherapy for locally advanced cervical cancer and its relation to urinary toxicity

    Science.gov (United States)

    Zakariaee, Roja; Hamarneh, Ghassan; Brown, Colin J.; Gaudet, Marc; Aquino-Parsons, Christina; Spadinger, Ingrid

    2016-12-01

    The purpose of this study was to estimate locally accumulated dose to the bladder in multi-fraction high-dose-date (HDR) image-guided intracavitary brachytherapy (IG-ICBT) for cervical cancer, and study the locally-accumulated dose parameters as predictors of late urinary toxicity. A retrospective study of 60 cervical cancer patients who received five HDR IG-ICBT sessions was performed. The bladder outer and inner surfaces were segmented for all sessions and a bladder-wall contour point-set was created in MATLAB. The bladder-wall point-sets for each patient were registered using a deformable point-set registration toolbox called coherent point drift (CPD), and the fraction doses were accumulated. Various dosimetric and volumetric parameters were calculated using the registered doses, including r{{\\text{D}}n \\text{c{{\\text{m}}\\text{3}}}} (minimum dose to the most exposed n-cm3 volume of bladder wall), r V n Gy (wall volume receiving at least m Gy), and r\\text{EQD}{{2}n \\text{c{{\\text{m}}\\text{3}}}} (minimum equivalent biologically weighted dose to the most exposed n-cm3 of bladder wall), where n  =  1/2/5/10 and m  =  3/5/10. Minimum dose to contiguous 1 and 2 cm3 hot-spot volumes was also calculated. The unregistered dose volume histogram (DVH)-summed equivalent of r{{\\text{D}}n \\text{c{{\\text{m}}3}}} and r\\text{EQD}{{2}n \\text{c{{\\text{m}}3}}} parameters (i.e. s{{\\text{D}}n \\text{c{{\\text{m}}\\text{3}}}} and s\\text{EQD}{{2}n \\text{c{{\\text{m}}3}}} ) were determined for comparison. Late urinary toxicity was assessed using the LENT-SOMA scale, with toxicity Grade 0-1 categorized as Controls and Grade 2-4 as Cases. A two-sample t-test was used to identify the differences between the means of Control and Case groups for all parameters. A binomial logistic regression was also performed between the registered dose parameters and toxicity grouping. Seventeen patients were in the Case and 43 patients in the Control group. Contiguous

  8. Cervical cancer outcome prediction to high-dose rate brachytherapy using quantitative magnetic resonance imaging analysis of tumor response to external beam radiotherapy

    International Nuclear Information System (INIS)

    Minkoff, David; Gill, Beant S.; Kang, John; Beriwal, Sushil

    2015-01-01

    Background and purpose: In order to assess tumor regression and outcomes, a volumetric analysis was conducted for cervical cancer patients treated with magnetic resonance imaging (MRI)-based image-guided brachytherapy (IGBT). Materials and methods: Consecutive patients with FIGO stage IB1–IVA cervical cancer receiving chemoradiation from 2007 to 2013 were identified, excluding patients with perineal template-based interstitial brachytherapy or without undergoing MRI. A ring and tandem applicator ± interstitial needles was used. T2-weighted imaging was completed following applicator insertion. Gross tumor volumes (GTVs) were retrospectively contoured: initial GTV (GTV Pre-EBRT ), GTV at first brachytherapy (GTV IGBT ) and percent residual GTV at first brachytherapy (% GTV Residual ). Results: Eighty-four patients were identified. With 20.8-month median follow-up, two-year estimates of local control (LC), disease-free survival (DFS) and overall survival (OS) were 91.3, 79.8, and 85.0%, respectively. Multivariate Cox regression revealed adenocarcinoma (HR 5.88, p = 0.03) and GTV IGBT (HR 1.17, p < 0.01) as predictors for local failure. GTV IGBT > 7.5 cc was associated with inferior 2-year LC (75.0 vs. 96.6%, p < 0.01), DFS (42.6 vs. 91.6%, p < 0.01) and OS (65.2 vs. 91.5%, p < 0.01). No difference in mean HRCTV D 90 EQD 2 was seen between the groups (p = 0.61). Conclusion: Aside from known benefits of IGBT, MRI-based planning allows for assessment of tumor regression and prognosticates patients

  9. Set the initial reference state of a team brachytherapy high dose rate; Establecimiento del estado de referencia inicial de un equipo de braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Clemente Gutierrez, F.; Diaz Fuentes, R.; Cabello Murillo, E.; Casa de Julian, M. A. de la; Ferrando Sanchez, A.; Adaimi Hernandez, P.

    2011-07-01

    You have set the initial reference state for a team of high-rate brachytherapy doses according to the recommendations made in the text used as a reference, being always within the functional tolerances established for the team, or the number associated with each test. The team was ready for clinical use under the provisions of Royal Decree 1566/1998 of Quality Control in Radiotherapy.

  10. Design and implementation of a film dosimetry audit tool for comparison of planned and delivered dose distributions in high dose rate (HDR) brachytherapy

    Science.gov (United States)

    Palmer, Antony L.; Lee, Chris; Ratcliffe, Ailsa J.; Bradley, David; Nisbet, Andrew

    2013-10-01

    A novel phantom is presented for ‘full system’ dosimetric audit comparing planned and delivered dose distributions in HDR gynaecological brachytherapy, using clinical treatment applicators. The brachytherapy applicator dosimetry test object consists of a near full-scatter water tank with applicator and film supports constructed of Solid Water, accommodating any typical cervix applicator. Film dosimeters are precisely held in four orthogonal planes bisecting the intrauterine tube, sampling dose distributions in the high risk clinical target volume, points A and B, bladder, rectum and sigmoid. The applicator position is fixed prior to CT scanning and through treatment planning and irradiation. The CT data is acquired with the applicator in a near clinical orientation to include applicator reconstruction in the system test. Gamma analysis is used to compare treatment planning system exported RTDose grid with measured multi-channel film dose maps. Results from two pilot audits are presented, using Ir-192 and Co-60 HDR sources, with a mean gamma passing rate of 98.6% using criteria of 3% local normalization and 3 mm distance to agreement (DTA). The mean DTA between prescribed dose and measured film dose at point A was 1.2 mm. The phantom was funded by IPEM and will be used for a UK national brachytherapy dosimetry audit.

  11. Design and implementation of a complementary treatment planning software for the GZP6 high dose rate brachytherapy system (GZP6 CTPS)

    International Nuclear Information System (INIS)

    Hariri Tabrizi, S.; Kamali Asl, A.; Azma, Z.

    2010-01-01

    Brachytherapy is one of the most common treatment modalities for gynecological cancer. The GZP6 brachytherapy system is one of the devices utilized in Iran. It has been considered particularly due to its low cost compared to other more complete and established systems. This system has some deficiencies including lack of a treatment planning software for non-predefined treatments, inability to change the gradually changeable dosimetric variables and using a point source estimation in dose calculation. This report presents a complementary treatment planning software to the system's own dedicated program. Material and Methods:. First, the dosimetric characteristics of three GZP6 sources were calculated based on the TG-43 protocol using the MCNP4C Monte Carlo code. Then, the calculated dose distribution around the implanted applicators, based on the selected dwell positions and dwell times, was shown in a graphical user interface written using the MATLAB software. Results: The computation uncertainty in the resulting TG-43 parameters was about 1% and the calculated parameters were in good agreement with similar studies on cobalt-60 source dosimetry. Furthermore, the graphical user interface is prepared as a user-friendly executable file which can be installed on any operating system. Discussion and Conclusion: Since different patients have distinct anatomy and physical conditions, a program for non-predefined situations of source arrangement is necessary. Using GZP6 complementary treatment planning software can satisfy this requirement.

  12. A quality indicator to evaluate high-dose-rate intracavitary brachytherapy for cancer of the cervix; Determinacao de um indicador de qualidade para avaliar a braquiterapia intracavitaria com alta taxa de dose no cancer do colo uterino

    Energy Technology Data Exchange (ETDEWEB)

    Morales, Francisco Contreras; Soboll, Daniel Scheidegger [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Radioterapia. Servico de Fisica Medica

    2000-12-01

    The aim of this report is to prevent a simple quality indicator (QI) that can be promptly used to evaluate the high-dose-rate (HDR) intracavitary brachytherapy for the treatment of cancer of the cervix, and if necessary, to correct applicators' geometry before starting the treatment. We selected 51 HDR intracavitary applications of brachytherapy of patients with carcinoma of the cervix treated with 60 mm uterine tandem and small Fletcher colpostat, according to the Manchester method (dose prescription on point A). A QI was defined as the ratio between the volume of 100% isodose curve of the study insertion and the volume of the 100% isodose curve of an insertion considered to be ideal. The data obtained were distributed in three groups: the group with tandem placement slippage (67,5%), a group with colpostat placement slippage (21,9%), and a third group, considered normal (10,6%). Each group showed particular characteristics (p < 0.0001). QI can be the best auxiliary method to establish the error tolerance (%) allowed for HDR intracavitary brachytherapy. (author)

  13. Combination of high-dose rate brachytherapy and external beam radiotherapy for the treatment of advanced scalp angiosarcoma - case report; Braquiterapia de alta taxa de dose associada a radioterapia externa no tratamento de angiossarcoma extenso do couro cabeludo - relato de caso

    Energy Technology Data Exchange (ETDEWEB)

    Gentil, Andre Cavalcanti; Lima Junior, Carlos Genesio Bezerra [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil). Dept. de Radioterapia]. E-mail: andregentil@hotmail.com; Soboll, Danyel Scheidegger; Novaes, Paulo Eduardo R.S.; Pereira, Adelino Jose; Pellizon, Antonio Carlos Assis [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Centro de Tratamento e Pequisa

    2001-10-01

    The authors report a case of a patient with an extensive angiosarcoma of the scalp that was submitted only to radiotherapy with a combination of orthovoltage roentgentherapy and high-dose rate brachytherapy, using a mould. The clinical and technical features as well as the therapeutic outcome are presented, and the usefulness and peculiarities of high-dose rate brachytherapy for this particular indication is discussed. A comparative analysis of the difficulties and limitations of employing low-dose rate brachytherapy is also presented. The authors concluded that high-dose rate brachytherapy might be an useful, practical and safe option to treat neoplastic lesions of the scalp, and an alternative treatment to electrontherapy. (author)

  14. Acute genitourinary toxicity after high dose rate (HDR) brachytherapy combined with hypofractionated external-beam radiation therapy for localized prostate cancer: Second analysis to determine the correlation between the urethral dose in HDR brachytherapy and the severity of acute genitourinary toxicity

    International Nuclear Information System (INIS)

    Akimoto, Tetsuo; Katoh, Hiroyuki; Noda, Shin-ei; Ito, Kazuto; Yamamoto, Takumi; Kashiwagi, Bunzo; Nakano, Takashi

    2005-01-01

    Purpose: We have been treating localized prostate cancer with high-dose-rate (HDR) brachytherapy combined with hypofractionated external beam radiation therapy (EBRT) at our institution. We recently reported the existence of a correlation between the severity of acute genitourinary (GU) toxicity and the urethral radiation dose in HDR brachytherapy by using different fractionation schema. The purpose of this study was to evaluate the role of the urethral dose in the development of acute GU toxicity more closely than in previous studies. For this purpose, we conducted an analysis of patients who had undergone HDR brachytherapy with a fixed fractionation schema combined with hypofractionated EBRT. Methods and Materials: Among the patients with localized prostate cancer who were treated by 192-iridium HDR brachytherapy combined with hypofractionated EBRT at Gunma University Hospital between August 2000 and November 2004, we analyzed 67 patients who were treated by HDR brachytherapy with the fractionation schema of 9 Gy x two times combined with hypofractionated EBRT. Hypofractionated EBRT was administered at a fraction dose of 3 Gy three times weekly, and a total dose of 51 Gy was delivered to the prostate gland and seminal vesicles using the four-field technique. No elective pelvic irradiation was performed. After the completion of EBRT, all the patients additionally received transrectal ultrasonography-guided HDR brachytherapy. The planning target volume was defined as the prostate gland with a 5-mm margin all around, and the planning was conducted based on computed tomography images. The tumor stage was T1c in 13 patients, T2 in 31 patients, and T3 in 23 patients. The Gleason score was 2-6 in 12 patients, 7 in 34 patients, and 8-10 in 21 patients. Androgen ablation was performed in all the patients. The median follow-up duration was 11 months (range 3-24 months). The toxicities were graded based on the Radiation Therapy Oncology Group and the European Organization

  15. Braquiterapia intersticial para recidivas de câncer de colo uterino pós-radioterapia Interstitial high-dose rate brachytherapy for recurrent cervical cancer after radiation therapy

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Zuliani de Oliveira

    2005-04-01

    Full Text Available OBJETIVO: Analisar a resposta e toxicidade da braquiterapia de alta taxa de dose (BATD intersticial para carcinoma do colo do útero com recidiva pélvica pós-radioterapia. MATERIAIS E MÉTODOS: Entre 1998 e 2001, 11 pacientes com carcinoma de colo de útero e que tiveram recidiva pélvica pós-radioterapia receberam BATD intersticial. Idade: 41 a 71 anos (média: 56,5 anos; estádios (FIGO: IIA, IIB, IIIB e IVA. Nove (82% pacientes tinham carcinoma de células escamosas e duas (18%, adenocarcinoma. Dose total de BATD: 20-30 Gy, em frações de 4-5 Gy. O seguimento variou de dois a 54 meses (média: 22,5 meses, através de exame físico periódico (três meses. Uma paciente faleceu sem avaliação de resposta. RESULTADOS: Dez pacientes (91% tiveram resposta clínica completa, com duração de três a 46 meses (média: 18,9 meses. Três pacientes estão livres de doença (27%, duas estão vivas com doença (18%, três morreram (27% e de três se perdeu o seguimento após nova recidiva (27%. A toxicidade para o trato urinário foi de 9% (uma paciente - grau III. CONCLUSÃO: A BATD intersticial é uma abordagem alternativa e viável para pacientes selecionadas que tiveram recidiva pós-radioterapia. Foi possível obter altas taxas de resposta com baixa toxicidade, considerando-se o grupo estudado, o tempo de seguimento e a re-irradiação.OBJECTIVE: To evaluate the response and potential toxicity of fractionated interstitial high-dose rate (HDR brachytherapy for post-radiation pelvic recurrence in cervical cancer. MATERIALS AND METHODS: From 1998 to 2001, 11 patients aged 41 to 71 years with cervical carcinoma stages II to IV who presented pelvic recurrence after radiation therapy were treated wit interstitial HDR. Nine of these patients (82% had squamous cell carcinoma and two had adenocarcinoma. Radiation consisted of 20 Gy to 30 Gy delivered in fractions of 4 Gy to 5 Gy over three days. The median follow-up was 22.5 months (2 to 54 months, with

  16. Evaluation of hybrid inverse planning and optimization (HIPO) algorithm for optimization in real-time, high-dose-rate (HDR) brachytherapy for prostate.

    Science.gov (United States)

    Pokharel, Shyam; Rana, Suresh; Blikenstaff, Joseph; Sadeghi, Amir; Prestidge, Bradley

    2013-07-08

    The purpose of this study is to investigate the effectiveness of the HIPO planning and optimization algorithm for real-time prostate HDR brachytherapy. This study consists of 20 patients who underwent ultrasound-based real-time HDR brachytherapy of the prostate using the treatment planning system called Oncentra Prostate (SWIFT version 3.0). The treatment plans for all patients were optimized using inverse dose-volume histogram-based optimization followed by graphical optimization (GRO) in real time. The GRO is manual manipulation of isodose lines slice by slice. The quality of the plan heavily depends on planner expertise and experience. The data for all patients were retrieved later, and treatment plans were created and optimized using HIPO algorithm with the same set of dose constraints, number of catheters, and set of contours as in the real-time optimization algorithm. The HIPO algorithm is a hybrid because it combines both stochastic and deterministic algorithms. The stochastic algorithm, called simulated annealing, searches the optimal catheter distributions for a given set of dose objectives. The deterministic algorithm, called dose-volume histogram-based optimization (DVHO), optimizes three-dimensional dose distribution quickly by moving straight downhill once it is in the advantageous region of the search space given by the stochastic algorithm. The PTV receiving 100% of the prescription dose (V100) was 97.56% and 95.38% with GRO and HIPO, respectively. The mean dose (D(mean)) and minimum dose to 10% volume (D10) for the urethra, rectum, and bladder were all statistically lower with HIPO compared to GRO using the student pair t-test at 5% significance level. HIPO can provide treatment plans with comparable target coverage to that of GRO with a reduction in dose to the critical structures.

  17. SU-F-19A-03: Dosimetric Advantages in Critical Structure Dose Sparing by Using a Multichannel Cylinder in High Dose Rate Brachytherapy to Treat Vaginal Cuff Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Syh, J; Syh, J; Patel, B; Zhang, J; Wu, H; Rosen, L [Willis-Knighton Cancer Center, Shreveport, LA (United States)

    2014-06-15

    Purpose: The multichannel cylindrical vaginal applicator is a variation of traditional single channel cylindrical vaginal applicator. The multichannel applicator has additional peripheral channels that provide more flexibility in the planning process. The dosimetric advantage is to reduce dose to adjacent organ at risk (OAR) such as bladder and rectum while maintaining target coverage with the dose optimization from additional channels. Methods: Vaginal HDR brachytherapy plans are all CT based. CT images were acquired in 2 mm thickness to keep integrity of cylinder contouring. The CTV of 5mm Rind with prescribed treatment length was reconstructed from 5mm expansion of inserted cylinder. The goal was 95% of CTV covered by 95% of prescribed dose in both single channel planning (SCP)and multichannel planning (MCP) before proceeding any further optimization for dose reduction to critical structures with emphasis on D2cc and V2Gy . Results: This study demonstrated noticeable dose reduction to OAR was apparent in multichannel plans. The D2cc of the rectum and bladder were showing the reduced dose for multichannel versus single channel. The V2Gy of the rectum was 93.72% and 83.79% (p=0.007) for single channel and multichannel respectively (Figure 1 and Table 1). To assure adequate coverage to target while reducing the dose to the OAR without any compromise is the main goal in using multichannel vaginal applicator in HDR brachytherapy. Conclusion: Multichannel plans were optimized using anatomical based inverse optimization algorithm of inverse planning simulation annealing. The optimization solution of the algorithm was to improve the clinical target volume dose coverage while reducing the dose to critical organs such as bladder, rectum and bowels. The comparison between SCP and MCP demonstrated MCP is superior to SCP where the dwell positions were based on geometric array only. It concluded that MCP is preferable and is able to provide certain features superior to SCP.

  18. Breast conserving treatment of breast carcinoma T2 (≤ 4 cm) and T3 by neoadjuvant chemotherapy, quadrantectomy, high dose rate brachytherapy as a boost, external beam radiotherapy and adjuvant chemotherapy: local control and overall survival analysis

    International Nuclear Information System (INIS)

    Soares, Celia Regina; Miziara Filho, Miguel Abrao; Fogaroli, Ricardo Cesar; Baraldi, Helena Espindola; Pellizzon, Antonio Cassio Assis; Pelosi, Edilson Lopes

    2008-01-01

    Objective: to assess the treatment of breast cancer T2 (≤ 4 cm) and T3 through neoadjuvant chemotherapy, quadrantectomy and high dose rate brachytherapy as a boost, complementary radiotherapy and adjuvant chemotherapy, considering local control and overall survival. Material and method: this clinical prospective descriptive study was based on the evaluation of 88 patients ranging from 30 to 70 years old, with infiltrating ductal carcinoma, clinical stage IIb and IIIa, responsive to the neoadjuvant chemotherapy, treated from June/1995 to December/2006. Median follow-up was 58 months. Using clinical methods the tumor was evaluated before and after three or four cycles of chemotherapy based on anthracyclines. Overall survival and local control were assessed according to Kaplan-Meier methodology. Results: Local control and overall survival in five years were 90% and 73.5%, respectively. Conclusion: local control and overall survival were comparable to other forms of treatment. (author)

  19. Validation of mathematical models for the prediction of organs-at-risk dosimetric metrics in high-dose-rate gynecologic interstitial brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Damato, Antonio L.; Viswanathan, Akila N.; Cormack, Robert A. [Dana-Farber Cancer Institute and Brigham and Women' s Hospital, Boston, Massachusetts 02115 (United States)

    2013-10-15

    Purpose: Given the complicated nature of an interstitial gynecologic brachytherapy treatment plan, the use of a quantitative tool to evaluate the quality of the achieved metrics compared to clinical practice would be advantageous. For this purpose, predictive mathematical models to predict the D{sub 2cc} of rectum and bladder in interstitial gynecologic brachytherapy are discussed and validated.Methods: Previous plans were used to establish the relationship between D2cc and the overlapping volume of the organ at risk with the targeted area (C0) or a 1-cm expansion of the target area (C1). Three mathematical models were evaluated: D{sub 2cc}=α*C{sub 1}+β (LIN); D{sub 2cc}=α– exp(–β*C{sub 0}) (EXP); and a mixed approach (MIX), where both C{sub 0} and C{sub 1} were inputs of the model. The parameters of the models were optimized on a training set of patient data, and the predictive error of each model (predicted D{sub 2cc}− real D{sub 2cc}) was calculated on a validation set of patient data. The data of 20 patients were used to perform a K-fold cross validation analysis, with K = 2, 4, 6, 8, 10, and 20.Results: MIX was associated with the smallest mean prediction error <6.4% for an 18-patient training set; LIN had an error <8.5%; EXP had an error <8.3%. Best case scenario analysis shows that an error ≤5% can be achieved for a ten-patient training set with MIX, an error ≤7.4% for LIN, and an error ≤6.9% for EXP. The error decreases with the increase in training set size, with the most marked decrease observed for MIX.Conclusions: The MIX model can predict the D{sub 2cc} of the organs at risk with an error lower than 5% with a training set of ten patients or greater. The model can be used in the development of quality assurance tools to identify treatment plans with suboptimal sparing of the organs at risk. It can also be used to improve preplanning and in the development of real-time intraoperative planning tools.

  20. Attenuation measurements show that the presence of a TachoSil surgical patch will not compromise target irradiation in intra-operative electron radiation therapy or high-dose-rate brachytherapy.

    Science.gov (United States)

    Sarmento, Sandra; Costa, Filipa; Pereira, Alexandre; Lencart, Joana; Dias, Anabela; Cunha, Luís; Sousa, Olga; Silva, José Pedro; Santos, Lúcio

    2015-01-09

    Surgery of locally advanced and/or recurrent rectal cancer can be complemented with intra-operative electron radiation therapy (IOERT) to deliver a single dose of radiation directly to the unresectable margins, while sparing nearby sensitive organs/structures. Haemorrhages may occur and can affect the dose distribution, leading to an incorrect target irradiation. The TachoSil (TS) surgical patch, when activated, creates a fibrin clot at the surgical site to achieve haemostasis. The aim of this work was to determine the effect of TS on the dose distribution, and ascertain whether it could be used in combination with IOERT. This characterization was extended to include high dose rate (HDR) intraoperative brachytherapy, which is sometimes used at other institutions instead of IOERT. CT images of the TS patch were acquired for initial characterization. Dosimetric measurements were performed in a water tank phantom, using a conventional LINAC with a hard-docking system of cylindrical applicators. Percentage Depth Dose (PDD) curves were obtained, and measurements made at the depth of dose maximum for the three clinically used electron energies (6, 9 and 12MeV), first without any attenuator and then with the activated patch of TS completely covering the tip of the IOERT applicator. For HDR brachytherapy, a measurement setup was improvised using a solid water phantom and a Farmer ionization chamber. Our measurements show that the attenuation of a TachoSil patch is negligible, both for high energy electron beams (6 to 12MeV), and for a HDR (192)Ir brachytherapy source. Our results cannot be extrapolated to lower beam energies such as 50 kVp X-rays, which are sometimes used for breast IORT. The TachoSil surgical patch can be used in IORT procedures using 6MeV electron energies or higher, or HDR (192)Ir brachytherapy.

  1. High dose rate brachytherapy in the treatment of endometrium carcinoma; Tratamento de cancer do endometrio com braquiterapia de alta taxa de dose

    Energy Technology Data Exchange (ETDEWEB)

    Aisen, Salim; Carvalho, Heloisa A.; Nadalin, Wladimir [Sao Paulo Univ., SP (Brazil). Hospital das Clinicas. Servico de Radioterapia

    1995-11-01

    One hundred and four patients with histologic proven carcinoma of the endometrium were referred to our department for treatment. The median age was 65.5 years and the median follow-up was 38 months. Ninety-five was pos-menopaused, 7 peri and 2 were pre-menopaused. Sixteen patients were staged (pos-surgery) IA, 5 GI, 8 G2 and 3 G3. Thirty and four stage IB, 10 G1, 18 G2 and 1 G3. Twenty-five were stage IC, 9 G1, 9 G2 and 7 G3. Six were stage IIA, 2 GI, 3 G2 and 1 G3. Eight were stages IIB, 1 G1,3 G2 and 4 G3. Nine were stage IIA, 2 GI, 5 G2, 2 G3. Three were stage IIIB, 2 GI and 1 G2. One was stage III C G3, and two were IVA G3. Depending of the extension of the disease, patients underwent total hysterectomy and bilateral salpino-ooforectomy, or total hysterectomy and bilateral salpino-ooforectomy plus omentectomy or Werthein-Megs technique. All the patients IA and IB have no evidence of disease (NED). Twenty-four patients IC are NED and one presented distant metastasis. From the IIB patients, 6 are NED, one shown progressive local disease (PLD) and one died from disease. From the patients IIIA, 7 are NED, one DM and one PLD. From the IIIB patients one is NED and TWO are PLD. From the IIIC patient is NED two months after treatment and the IVA patients are NED three and four month after treatment. Eight patients have shown mild complications of treatment. The results of survival and complications are similar to the therapeutic with low dose rate brachytherapy, with the advantage of an outpatient treatment, without the inconvenience of impatient regime. (author). 22 refs., 1 tab.

  2. Computed Tomography–Guided Interstitial High-Dose-Rate Brachytherapy in Combination With Regional Positive Lymph Node Intensity-Modulated Radiation Therapy in Locally Advanced Peripheral Non–Small Cell Lung Cancer: A Phase 1 Clinical Trial

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, Li; Zhang, Jian-wen; Lin, Sheng; Luo, Hui-Qun; Wen, Qing-Lian; He, Li-Jia; Shang, Chang-Ling; Ren, Pei-Rong; Yang, Hong-Ru; Pang, Hao-Wen; Yang, Bo; He, Huai-Lin [Department of Oncology, Affiliated Hospital of Luzhou Medical College, Luzhou (China); Chen, Yue, E-mail: chenyue5523@126.com [Department of Nuclear Medicine, Affiliated Hospital of Luzhou Medical College, Luzhou (China); Wu, Jing-Bo, E-mail: wjb6147@163.com [Department of Oncology, Affiliated Hospital of Luzhou Medical College, Luzhou (China)

    2015-08-01

    Purpose: To assess the technical safety, adverse events, and efficacy of computed tomography (CT)-guided interstitial high-dose-rate (HDR) brachytherapy in combination with regional positive lymph node intensity modulated radiation therapy in patients with locally advanced peripheral non–small cell lung cancer (NSCLC). Methods and Materials: Twenty-six patients with histologically confirmed NSCLC were enrolled in a prospective, officially approved phase 1 trial. Primary tumors were treated with HDR brachytherapy. A single 30-Gy dose was delivered to the 90% isodose line of the gross lung tumor volume. A total dose of at least 70 Gy was administered to the 95% isodose line of the planning target volume of malignant lymph nodes using 6-MV X-rays. The patients received concurrent or sequential chemotherapy. We assessed treatment efficacy, adverse events, and radiation toxicity. Results: The median follow-up time was 28 months (range, 7-44 months). There were 3 cases of mild pneumothorax but no cases of hemothorax, dyspnea, or pyothorax after the procedure. Grade 3 or 4 acute hematologic toxicity was observed in 5 patients. During follow-up, mild fibrosis around the puncture point was observed on the CT scans of 2 patients, but both patients were asymptomatic. The overall response rates (complete and partial) for the primary mass and positive lymph nodes were 100% and 92.3%, respectively. The 1-year and 2-year overall survival (OS) rates were 90.9% and 67%, respectively, with a median OS of 22.5 months. Conclusion: Our findings suggest that HDR brachytherapy is safe and feasible for peripheral locally advanced NSCLC, justifying a phase 2 clinical trial.

  3. SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

    Energy Technology Data Exchange (ETDEWEB)

    Harpool, K; De La Fuente Herman, T; Ahmad, S; Ali, I [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States)

    2016-06-15

    Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and

  4. Using the computed tomography in comparison to the orthogonal radiography based treatment planning in high dose rate (HDR) brachytherapy in cervical uteri cancer patients; a single institution feasibility study.

    Science.gov (United States)

    Bahadur, Yasir A; El-Sayed, Mohamed E; El-Taher, Zeinab H; Zaza, Khaled O; Moftah, Belal A; Hassouna, Ashraf H; Ghassal, Noor M

    2008-03-01

    Brachytherapy is an integral part in the treatment of cervical uteri cancer patients. Orthogonal treatment planning is the standard mode of calculation based on reference points. Introduction of the innovative 3-D computer based treatment planning allows accurate calculation based on volumetric information as regards the target volume and organs at risk (OAR). Also provide dose volume histogram (DVH) for proper estimation of the dose in relation to the volume. To correlate and compare the information obtained from the two approaches for high dose rate brachytherapy of cervical uteri cancer; the orthogonal conventional method and the computerized tomography (CT) three dimensions (3D) based calculation method in relation to the target and organ at risk (OAR). From 6 patients of cervical uteri cancer, 21 applications with orthogonal planning using the Brachy Vision treatment planning system version 7.3.10 were performed. In 10 applications; comparison between orthogonal and CT based planning was done. In orthogonal planning; the dose to point A, rectum and bladder were defined according to the American Brachytherapy Society (ABS) recommendation. From the CT based planning the target volume and dose volume histogram lpar;DVH) were calculated for the clinical target volume (CTV), rectum and bladder. From these two sets, information was obtained and compared and mean values were derived. For dose prescription at point A, an average of 63.5% of CTV received the prescribed dose. The mean ICRU dose to the bladder point is 2.9 Gy+/-1.2 SD (Standard Deviation) and 17% of the bladder volume derived from CT was encompassed by 2.9 Gy isodose line. The mean ICRU dose at the rectum point is 3.4 Gy+/-1.2 SD and 21% of the rectum volume from CT was encompassed by 3.4 Gy isodose line. The maximum dose to the rectum and the bladder derived from the CT and compared to the maximal dose at ICRU is 1.7 and 2.8 times higher than the orthogonal reference points; with the corresponding p

  5. Using the Computed Tomography in Comparison to the Orthogonal Radiography Based Treatment Planning in High dose Rate (HDR) Brachytherapy in Cervical Uteri Cancer Patients; A Single Institution Feasibility Study

    International Nuclear Information System (INIS)

    BAHADUR, Y.A.; EL-SAYED, M.E.; HASSOUNA, A.H.; EL-TAHER, Z.H.; GHASSAL, N.M.; ZAZA, Kh.O.M.D.; OFTAH, B.A.

    2008-01-01

    Brachytherapy is an integral part in the treatment of cervical uteri cancer patients. Orthogonal treatment planning is the standard mode of calculation based on reference points. Introduction of the innovative 3-D computer based treatment planning allows accurate calculation based on volumetric information as regards the target volume and organs at risk (OAR). Also provide dose volume histogram (DVH) for proper estimation of the dose in relation to the volume. Aim: To correlate and compare the information obtained from the two approaches for high dose rate brachytherapy of cervical uteri cancer; the orthogonal conventional method and the computerized tomography (CT) three dimensions (3D) based calculation method in relation to the target and organ at risk (OAR). Methods: From 6 patients of cervical uteri cancer, 21 applications with orthogonal planning using the Brachy Vision treatment planning system version 7.3.10 were performed. In 10 applications; comparison between orthogonal and CT based planning was done. In orthogonal planning; the dose to point A, rectum and bladder were defined according to the American Brachytherapy Society (ABS) recommendation. From the CT based planning the target volume and dose volume histogram (DVH) were calculated for the clinical target volume (CTV), rectum and bladder. From these two sets, information was obtained and compared and mean values were derived. Results: For dose prescription at point A, an average of 63.5% of CTV received the prescribed dose. The mean ICRU dose to the bladder point is 2.9 Gy±l .2 SD (Standard Deviation) and 17% of the bladder volume derived from CT was encompassed by 2.9 Gy isodose line. The mean ICRU dose at the rectum point is 3.4 Gy±1.2 SD and 21% of the rectum volume from CT was encompassed by 3.4 Gy isodose line. The maximum dose to the rectum and the bladder derived from the CT and compared to the maximal dose at ICRU is 1.7 and 2.8 times higher than the orthogonal reference points; with the

  6. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  7. Concomitant chemoradiotherapy with high dose rate brachytherapy ...

    African Journals Online (AJOL)

    Tamer Refaat

    2011-06-12

    Jun 12, 2011 ... from common iliac nodes. The following borders were used: 2.3.2. AP-PA portals. Superior: One centimeter above the inferior aspect of the sacro- iliac joints, extended ... Based on linear quadratic model, bio- logic effective dose ..... tive evidence suggests that this protein functions as a mediator of cellular ...

  8. Braquiterapia endoluminal HDR no tratamento de tumores primários ou recidivas na árvore traqueobrônquica Endoluminal high dose rate brachytherapy in the treatment of primary and recurrent bronchogenic tree malignancies

    Directory of Open Access Journals (Sweden)

    Maria Fortunato

    2009-03-01

    primários sintomáticos apresentam uma boa tolerância e um alívio sintomático associado a uma boa qualidade de vida. Apesar da reduzida amostra, os resultados demonstram as eventuais vantagens da BTE de HDR no tratamento paliativo/ curativo destes doentesIntroduction: Locally advanced tumours as the initial form of presentation of tumours in the bronchial tree are not a rare event. Bronchogenic recurrence is frequent in the natural history of some tumours. The choice of therapeutic options from the raft available depends on such variables as initial therapy, place of recurrence, symptoms and patient’s physical status. Aim: To demonstrate the advantages of endoluminal brachytherapy (EBT with high dose rate (HDR in primary and recurrent tumour of the bronchial tree. Material and methods: A retrospective study of seven patients (pts with primary tumours of the colon, trachea and lung. Tracheobronchial recurrence (trachea, two pts, bronchus, five pts occurred between March 2003 and September 2004. Patients under-went EBT with HDR for primary or recurrent therapy in association with external radiotherapy, laser therapy and chemotherapy with palliative or curative intention. EBT with HDR doses of 5 to 7 Gy in 2 to 4 fractions at 1 cm from the source axis were given. Treatment included endoluminal application of Ir192 with a French 6 catheter. Results: There was symptomatic relief related to reduction of tumour in six of the seven patients treated. In one of the six patients studied, there was progression of the local disease between the second and third fractions of the treatment (obstruction of the trachea. In a mean follow up of 17 (2-40 months between EBT and this study, three patients are alive, one has no evidence of disease while two have had bronchial recurrence, four patients have died, one after massive haemoptysis and three due to disease progression. Discussion and conclusions: Patients undergoing brachytherapy for symptomatic primary tumours or

  9. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE® radiochromic plastic

    International Nuclear Information System (INIS)

    Palmer, A. L.; Di Pietro, P.; Alobaidli, S.; Issa, F.; Doran, S.; Bradley, D.; Nisbet, A.

    2013-01-01

    Purpose: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE ® with optical-CT readout. Methods: Ge-doped SiO 2 fibers with 6 μm active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 μm active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE ® , 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. Results: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE ® , and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated

  10. Comparison of methods for the measurement of radiation dose distributions in high dose rate (HDR) brachytherapy: Ge-doped optical fiber, EBT3 Gafchromic film, and PRESAGE® radiochromic plastic.

    Science.gov (United States)

    Palmer, A L; Di Pietro, P; Alobaidli, S; Issa, F; Doran, S; Bradley, D; Nisbet, A

    2013-06-01

    Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE(®) with optical-CT readout. Ge-doped SiO2 fibers with 6 μm active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 μm active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE(®), 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE(®), and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for

  11. Dose-volume histogram parameters of high-dose-rate brachytherapy for Stage I-II cervical cancer (≤4cm) arising from a small-sized uterus treated with a point A dose-reduced plan

    International Nuclear Information System (INIS)

    Nakagawa, Akiko; Noda, Shin-ei; Kubo, Nobuteru; Kuwako, Keiko; Nakano, Takashi; Ohno, Tatsuya; Saitoh, Jun-ichi

    2014-01-01

    We investigated the rectal dose-sparing effect and tumor control of a point A dose-reduced plan in patients with Stage I-II cervical cancer (≤4 cm) arising from a small-sized uterus. Between October 2008 and August 2011, 19 patients with Stage I-II cervical cancer (≤4 cm) were treated with external beam radiotherapy (EBRT) for the pelvis and CT-guided brachytherapy. Seven patients were treated with brachytherapy with standard loading of source-dwell positions and a fraction dose of 6 Gy at point A (conventional brachy-plan). The other 12 patients with a small uterus close to the rectum or small intestine were treated with brachytherapy with a point A dose-reduction to match D2cc of the rectum and <6 Gy as the dose constraint ('point A dose-reduced plan') instead of the 6-Gy plan at point A ('tentative 6-Gy plan'). The total doses from EBRT and brachytherapy were added up and normalized to a biological equivalent dose of 2 Gy per fraction (EQD2). The median doses to the high-risk clinical target volume (HR-CTV) D90 in the conventional brachy-plan, tentative 6-Gy plan and point A dose-reduced plan were 62 GyEQD2, 80 GyEQD2 and 64 GyEQD2, respectively. The median doses of rectal D2cc in the corresponding three plans were 42 GyEQD2, 62 GyEQD2 and 51 GyEQD2, respectively. With a median follow-up period of 35 months, three patients developed Grade-1 late rectal complications and no patients developed local recurrence. Our preliminary results suggested that CT-guided brachytherapy using an individualized point A dose-reduced plan might be useful for reducing late rectal complications while maintaining primary tumor control. (author)

  12. Breast conserving treatment of locally advanced carcinoma T2 and T3 after neoadjuvant chemotherapy followed by quadrantectomy and high dose-rate brachytherapy, as a boost, complementary teletherapy and adjuvant chemotherapy

    International Nuclear Information System (INIS)

    Fristachi, Carlos Elias

    2005-01-01

    Objective: to assess the treatment of breast cancer T2 and T3(T > = 4 cm), through neoadjuvant chemotherapy, quadrantectomy and high-dose-rate (HDR) brachytherapy as a boost, complementary radiotherapy and adjuvant chemotherapy, considering its method problems, its esthetics results, the aspect of local control, overall survival, and disease-free survival. Patients and method: this clinical prospective descriptive study was based on the evaluation of 26 patients ranging from 30 to 70 years old, with infiltrating ductal carcinoma, clinical stage IIB and IIIA, responsive to the neoadjuvant chemotherapy. Early and late radiotherapy complications were evaluated according to the criteria established by the RTOG/EORTC (Radiotherapy and Oncology Group /European Organization for Research and Treatment of Cancer) groups. Esthetics evaluation was done in accordance with the criteria set by a plastic surgeon. Local control was evaluated by clinical method, mammography and ultrasonography. Overall survival (OS) and the disease-free survival (DFS) were assessed according to Kaplan-Meier methodology. All the patients were treated at the Dr. Arnaldo Vieira de Carvalho Cancer Institute, from June/1995 to November/2001, and evaluated in March, 2002, with median follow-up of 28.7 months. Results: early complications were observed in 8 patients (30.6%). Two patients were classified as G3 and G4 (RTOG/EORTC). Six patients had late complications and three of them (11.5%) were classified as G3 and G4. One patient (3.8%) had local recurrence, 64 months after having local treatment. Esthetics results were considered good or regular in 16 patients (60.5%) out of 24 patients who were examined. Overall survival and disease-free survival in 24, 36 and 60 months were 100%, 92.3% and 83.1% respectively. Conclusion: early and late radiotherapy complications were considerate high when compared to literature, but esthetic results were considered acceptable. RL, OS and DFS were comparable to other

  13. Neoadjuvant androgen deprivation and long-term results for patients with intermediate- and high-risk prostate cancer treated with high-dose rate brachytherapy and external beam radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Pellizzon, Antonio Cassio Assis; Fogaroli, Ricardo Cesar; Silva, Maria Leticia Gobo; Castro, Douglas Guedes; Maia, Maria Conte, E-mail: acapellizzon@hcancer.org.b [Hospital A.C. Camargo, Sao Paulo, SP (Brazil). Radiation Oncology Dept.

    2010-07-01

    Purpose: to evaluate the influence of neoadjuvant androgen deprivation (NAAD) and report the long term biochemical control rates according to the Phoenix Consensus Conference, and prognostic factors of intermediate- (IR) and high-risk (HR) prostate cancer treated with external beam radiotherapy and high-dose-rate brachytherapy (HDR-BT). Methods and materials: between March, 1997 and June, 2005, 184 patients considered IR or HR were treated with localized radiotherapy and HDR-BT at the Department of Radiation Oncology, Hospital A.C. Camargo, Sao Paulo, Brazil. Patient's age, Gleason score, clinical stage, initial PSA value, risk group for biochemical failure, presence of NAAD, doses of radiotherapy and HDR-BT were evaluated. Results: median age and follow-up were 70 years old (range, 47-83) and 74.5 months (range, 24-123 months), respectively. Patients considered IR were 91 (49.4%) and HR 93 (50.6%). Ninety-nine (53.8%) patients had no NAAD. The overall survival at 5 years was 93.6%. The 5-year actuarial biochemical control rates for all patients, IR and HR were 83.4%, 86.2% and 78.8%, respectively, p0.076. On univariate analysis the prognostic factors related to better biochemical control were Gleason score < 6 ng/ml (p= 0.037), radiotherapy dose > 45 Gy (p= 0.011) and HDR-BT dose > 20 Gy (p< 0.001). On multivariate analysis no statistical significant predictive factor related to biochemical control was found. Conclusions: the role of NAAD for IR and HR prostate cancer is still to be defined. HDR-BT combined to external radiotherapy is a successful form of treatment for these patients, with our results comparable to published data. (author)

  14. Braquiterapia intersticial de alta tasa de rescate en cáncer cabeza cuello previamente radiado High-dose-rate (HDR brachytherapy in previously irradiated recurrent head and neck cancer

    Directory of Open Access Journals (Sweden)

    Lucía Gutiérrez-Bayard

    2011-09-01

    Full Text Available A pesar de los avances en el tratamiento de cáncer de cabeza y cuello (CCC, el 15-50% de los pacientes presentan recurrencia locorregional. Para los pacientes que presentan enfermedad localmente recurrente o un segundo tumor primario en un campo previamente irradiado, las opciones terapéuticas de rescate son limitadas, siendo la resección quirúrgica con intención curativa la opción de elección para los pacientes con enfermedad limitada. Reirradiación con o sin la adición de quimioterapia puede ser una buena opción, obteniendo en pacientes seleccionados supervivencia a largo plazo. La braquiterapia de alta tasa de dosis (HDRBT puede jugar un papel importante en el tratamiento de rescate en tumores de cabeza y cuello recurrentes. Presentamos un paciente de 56 años diagnosticado de cáncer de lengua sometido a cirugía y radioterapia externa adyuvante, y recurrencia metastásica ganglionar cervical contralateral a los 18 meses. Recibió tratamiento multidisciplinar con quimioterapia, cirugía y braquiterapia intersticial.Despite advances in the treatment of head and neck cancer (HNC, 15-50% of patients present locoregional disease recurrence. The therapeutic options are limited for patients who present locally recurrent disease or a second primary tumor in a previously irradiated field. Surgical salvage with curative intent is the preferred option for patients with limited-volume disease. Re-irradiation with or without the addition of chemotherapy may hold promise for long-term survival for selected patients. High-dose-rate (HDR brachytherapy can play an important role in the salvage treatment of previously irradiated recurrent head and neck cancer. The case reported was a 56-year old man diagnosed of tongue cancer who presented recurrent metastatic contralateral cervical node 1.5 years after radical treatment with surgery and adjuvant external radiotherapy. He received multidisciplinary treatment with chemotherapy, surgery and HDR

  15. Dose-volume histogram parameters of high-dose-rate brachytherapy for Stage I-II cervical cancer (≤4cm) arising from a small-sized uterus treated with a point A dose-reduced plan.

    Science.gov (United States)

    Nakagawa, Akiko; Ohno, Tatsuya; Noda, Shin-ei; Kubo, Nobuteru; Kuwako, Keiko; Saitoh, Jun-Ichi; Nakano, Takashi

    2014-07-01

    We investigated the rectal dose-sparing effect and tumor control of a point A dose-reduced plan in patients with Stage I-II cervical cancer (≤4 cm) arising from a small-sized uterus. Between October 2008 and August 2011, 19 patients with Stage I-II cervical cancer (≤4 cm) were treated with external beam radiotherapy (EBRT) for the pelvis and CT-guided brachytherapy. Seven patients were treated with brachytherapy with standard loading of source-dwell positions and a fraction dose of 6 Gy at point A (conventional brachy-plan). The other 12 patients with a small uterus close to the rectum or small intestine were treated with brachytherapy with a point A dose-reduction to match D2cc of the rectum and <6 Gy as the dose constraint ('point A dose-reduced plan') instead of the 6-Gy plan at point A ('tentative 6-Gy plan'). The total doses from EBRT and brachytherapy were added up and normalized to a biological equivalent dose of 2 Gy per fraction (EQD2). The median doses to the high-risk clinical target volume (HR-CTV) D90 in the conventional brachy-plan, tentative 6-Gy plan and point A dose-reduced plan were 62 GyEQD2, 80 GyEQD2 and 64 GyEQD2, respectively. The median doses of rectal D2cc in the corresponding three plans were 42 GyEQD2, 62 GyEQD2 and 51 GyEQD2, respectively. With a median follow-up period of 35 months, three patients developed Grade-1 late rectal complications and no patients developed local recurrence. Our preliminary results suggested that CT-guided brachytherapy using an individualized point A dose-reduced plan might be useful for reducing late rectal complications while maintaining primary tumor control. © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  16. Implementation of three-dimensional planning in brachytherapy of high dose rate for gynecology therapies; Implementacao de planejamento tridimensional em braquiterapia de alta taxa de dose para tratamentos ginecologicos

    Energy Technology Data Exchange (ETDEWEB)

    Sales, Camila Pessoa de

    2015-09-01

    This work aims to implement the three-dimensional (3D) planning for gynecological brachytherapy treatments. For this purpose, tests of acceptance and commissioning of brachytherapy equipment were performed to establish a quality and periodic assurance program. For this purpose, an important step was searching for a material to be used as a dummy source, since the applicators do not have any specific dummy. In addition, the validation of the use of applicators library was made for reconstruction in computed tomography (CT) and magnetic resonance imaging (MRI). In order to validate 3D planning, comparison of doses in dose assessment points used in bidimensional (2D) plans have been performed with volumetric doses to adjacent organs to the tumor. Finally, a protocol was established for 3D brachytherapy planning alternately using magnetic resonance image (MRI) and CT images, making evaluation of the dose in the tumor through the recording of MR and CT images. It was not possible to find a suitable material that could be used as dummy in MRI. However, the acquisition of the license's library for the applicators made possible the 3D planning based on MRI. No correlation was found between volumetric and specific doses analyzed, showing the importance of the implementation of 3D planning. The average ratio between D{sub 2cc} and ICRU{sub Bladder} dose was 1,74, 22% higher than the ratio found by others authors. For the rectum, D{sub 2cc} was less than dose point for 60% of fractions; the average difference was 12,5%. The average ratio between D{sub 2cc} and point dose rectum, 0,85, is equivalent to the value showed by Kim et al, 0,91. The D{sub 2cc} for sigmoid was 69% higher than point dose used, unless it was not possible compare this value, since the sigmoid point used in the 2D procedures is not used in others institutes. Relative dose in 2 cc of sigmoid was 57% of the prescription dose, the same value was found by in literature. This work enabled the

  17. Intraarterial 192Ir high-dose-rate brachytherapy for prophylaxis of restenosis after femoropopliteal percutaneous transluminal angioplasty: the prospective randomized Vienna-2-trial radiotherapy parameters and risk factors analysis

    International Nuclear Information System (INIS)

    Pokrajac, Boris; Poetter, Richard; Maca, Thomas; Fellner, Claudia; Mittlboeck, Martina; Ahmadi, Ramazanali; Seitz, Wolfgang; Minar, Erich

    2000-01-01

    Purpose: The aim of the Vienna-2-trial was to compare the restenosis rate of femoropopliteal arteries after percutaneous transluminal angioplasty (PTA) with or without intraarterial high-dose-rate (HDR) brachytherapy (BT) using an 192 Ir source. Materials and Methods: A prospective, randomized trial was conducted from 11/96 to 8/98. A total of 113 patients (63 men, 50 women), with a mean age of 71 years (range, 43-89 years) were included. Inclusion criteria were (1) claudication or critical limb ischemia, (2) de-novo stenosis of 5 cm or more, (3) restenosis after former PTA of any length, and (4) no stent implantation. Patients were randomized after successful PTA for BT vs. no further treatment. A well-balanced patient distribution was achieved for the criteria used for stratification, as there were 'de-novo stenosis vs. restenosis after former PTA', 'stenosis vs. occlusion', 'claudication vs. critical limb ischemia' and above these for 'diabetes vs. nondiabetes'. PTA length was not well balanced between the treatment arms: a PTA length of 4-10 cm was seen in 19 patients in the PTA alone group and in 11 patients in the PTA+BT group, whereas a PTA length of greater than10 cm was seen in 35 patients and 42 patients, respectively. A dose of 12 Gy was prescribed in 3-mm distance from the source axis. According to AAPM recommendations, the dose was 6.8 Gy in 5-mm distance (vessel radius + 2 mm). Primary endpoint of the study was femoropopliteal patency after 6 months. Results: PTA and additional BT were feasible and well tolerated by all 57 pts in this treatment arm. No acute, subacute, and late adverse side effects related to BT were seen after a mean follow up of 12 months (6-24 months) in 107 patients (PTA n = 54; PTA+ BT n = 53). Crude restenosis rate at 6 months was in the PTA arm 54% vs. 28% in the PTA + BT arm (χ 2 test; p 10 cm) showed significant decrease of the restenosis rate, if BT was added. Significant reduction was not achieved in diabetes patients

  18. Evaluation of short-term changes in the health-related quality of life of patients with localized prostate cancer receiving high-dose-rate brachytherapy with or without external beam radiotherapy. Comparison with patients receiving radical retropubic prostatectomy

    International Nuclear Information System (INIS)

    Yoshida, Kenji; Hiratsuka, Junichi; Jo, Yoshimasa; Imajo, Yoshinari

    2006-01-01

    The purpose of this study was to evaluate short-term changes in the health-related quality of life (HRQoL) of patients with localized prostate cancer receiving high-dose-rate brachytherapy (HDR-BT) with or without external beam radiotherapy (EBRT) and compare them with those in patients receiving radical retropubic prostatectomy (RRP). We have examined the HRQoL of a total of 92 men with localized prostate cancer receiving radical treatment at Kawasaki Medical School since May 1, 2004. Forty patients received HDR-BT+EBRT, 33 patients received HDR-BT alone, and 19 patients received RRP. We asked them to complete the 36-item Short-Form Health Survey (SF-36) and the University of California Los Angeles Prostate Cancer Index (UCLA-PCI) before and at one, and six months after treatment. Forty patients in the HDR-BT+EBRT group, 32 patients in the HDR-BT group, and 15 patients in the RRP group completed these HRQoL questionnaires. We examined short-term changes in the HRQoL scores in each group using Wilcoxon's signed rank test and compared the RT (HDR-BT+EBRT or HDR-BT) group with the RRP group using Mann-Whitney's U test. In each group, the scores of most aspects of these HRQoL questionnaires declined at one month after treatment and rose again at six months after treatment. This change was most notable in the HDR-BT+EBRT Group. In the post-treatment scores of both RT groups, urinary function (UF) and sexual function (SF) scores for the UCLA-PCI were better than those of the RRP group. The declination of these HRQoL scores seems to bear some relation to the acute effects of each treatment modality, especially in the HDR-BT+EBRT group. Urinary function and SF were more favorable for the RT groups, but the evaluation of SF was most difficult in this study. Since we believe it is necessary to carry out a long-term and minute examination to evaluate the HRQoL of patients with localized prostate cancer more accurately, this study will continue. (author)

  19. Dose rate-dependent marrow toxicity of TBI in dogs and marrow sparing effect at high dose rate by dose fractionation.

    Science.gov (United States)

    Storb, R; Raff, R F; Graham, T; Appelbaum, F R; Deeg, H J; Schuening, F G; Sale, G; Seidel, K

    1999-01-01

    We evaluated the marrow toxicity of 200 and 300 cGy total-body irradiation (TBI) delivered at 10 and 60 cGy/min, respectively, in dogs not rescued by marrow transplant. Additionally, we compared toxicities after 300 cGy fractionated TBI (100 cGy fractions) to that after single-dose TBI at 10 and 60 cGy/min. Marrow toxicities were assessed on the basis of peripheral blood cell count changes and mortality from radiation-induced pancytopenia. TBI doses studied were just below the dose at which all dogs die despite optimal support. Specifically, 18 dogs were given single doses of 200 cGy TBI, delivered at either 10 (n=13) or 60 (n=5) cGy/min. Thirty-one dogs received 300 cGy TBI at 10 cGy/min, delivered as either single doses (n=21) or three fractions of 100 cGy each (n=10). Seventeen dogs were given 300 cGy TBI at 60 cGy/min, administered either as single doses (n=5) or three fractions of 100 cGy each (n=10). Within the limitations of the experimental design, three conclusions were drawn: 1) with 200 and 300 cGy single-dose TBI, an increase of dose rate from 10 to 60 cGy/min, respectively, caused significant increases in marrow toxicity; 2) at 60 cGy/min, dose fractionation resulted in a significant decrease in marrow toxicities, whereas such a protective effect was not seen at 10 cGy/min; and 3) with fractionated TBI, no significant differences in marrow toxicity were seen between dogs irradiated at 60 and 10 cGy/min. The reduced effectiveness of TBI when a dose of 300 cGy was divided into three fractions of 100 cGy or when dose rate was reduced from 60 cGy/min to 10 cGy/min was consistent with models of radiation toxicity that allow for repair of sublethal injury in DNA.

  20. Determination of air kerma standard of high dose rate {sup 192}Ir brachytherapy source; Determinacao da taxa de kerma no ar de referencia para {sup 192}Ir de alta taxa de dose para braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de, E-mail: cfealves@gmail.com [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Lab. de Ciencias Radiologicas; Di Prinzio, R. [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of {sup 192}Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  1. Braquiterapia de alta taxa de dose associada a radioterapia externa no tratamento de angiossarcoma extenso do couro cabeludo: relato de caso Combination of high-dose rate brachytherapy and external beam radiotherapy for the treatment of advanced scalp angiosarcoma: case report

    Directory of Open Access Journals (Sweden)

    André Cavalcanti Gentil

    2001-10-01

    Full Text Available Os autores apresentam um caso de extenso angiossarcoma do couro cabeludo submetido a radioterapia exclusiva, pela associação de roentgenterapia de ortovoltagem e braquiterapia de alta taxa de dose utilizando um molde. Descrevem os aspectos clínicos, técnicos e a evolução terapêutica. Destacam as particularidades e a utilidade da braquiterapia de alta taxa de dose, nesta situação em particular, e fazem uma análise comparativa das dificuldades e limitações caso a braquiterapia de baixa taxa de dose fosse empregada. Concluem ser a braquiterapia de alta taxa de dose uma opção útil, prática e segura para as lesões neoplásicas superficiais do escalpe, podendo ser considerada uma alternativa ao tratamento com elétrons.The authors report a case of a patient with an extensive angiosarcoma of the scalp that was submitted only to radiotherapy with a combination of orthovoltage roentgentherapy and high-dose rate brachytherapy, using a mould. The clinical and technical features as well as the therapeutic outcome are presented, and the usefulness and peculiarities of high-dose rate brachytherapy for this particular indication is discussed. A comparative analysis of the difficulties and limitations of employing low-dose rate brachytherapy is also presented. The authors concluded that high-dose rate brachytherapy might be an useful, practical and safe option to treat neoplastic lesions of the scalp, and an alternative treatment to electrontherapy.

  2. High-dose-rate intracavitary brachytherapy combined with external beam radiotherapy for stage IIIb adenocarcinoma of the uterine cervix in Japan. A multi-institutional study of Japanese Society of Therapeutic Radiology and Oncology 2006-2007 (Study of JASTRO 2006-2007)

    International Nuclear Information System (INIS)

    Niibe, Yuzuru; Kenjo, Masahiro; Onishi, Hiroshi

    2010-01-01

    The current study was a retrospective questionnaire survey of stage IIIb adenocarcinoma of the uterine cervix treated with high-dose-rate intracavitary brachytherapy combined with external beam radiation therapy in Japan aimed to investigate the optimal dose on the basis of the biological effective dose and prognostic factors. Between 1990 and 2000, 61 patients with stage IIIb adenocarcinoma of the uterine cervix underwent high-dose-rate intracavitary brachytherapy combined with external beam radiation therapy in 19 major hospitals in Japan. This retrospective questionnaire survey was performed by mail including survey charts to be fulfilled by radiation oncologists in these 19 major hospital. Fifty had only adenocarcinoma components and 11 had adenosquamous cell carcinoma components. All patients were treated with high-dose-rate intracavitary brachytherapy combined with external beam radiation therapy. Total biological effective dose (T-BED 10 ) was calculated from the sum of the biological effective doses of the external beam radiation therapy and the intracavitary brachytherapy. Thirty-two patients underwent chemotherapy. The 5-year overall survival rate of all patients was 20.2%. Stratified by total biological effective dose, the 5-year overall survival rate was 0% for T-BED 10 10 between 75 and 100 Gy and 0% for T-BED 10 >110 Gy (P=0.15). Stratified by histopathology, the 5-year overall survival rate was 22.1% for adenocarcinoma and 13.6% for adenosquamous cell carcinoma (P=0.43). Stratified by chemotherapy, the 5-year overall survival rate was 20.3% in patients who received chemotherapy and 20.4% in patients who did not receive chemotherapy (P=0.96). The 5-year overall survival rate of stage IIIb adenocarcinoma of the uterine cervix in this retrospective questionnaire survey was 20.2%. The optimal T-BED 10 and evident prognostic factors were not clear from this questionnaire survey. (author)

  3. Avaliação da dose no reto em pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino Rectal dose assessment in patients submitted to high-dose-rate brachytherapy for uterine cervix cancer

    Directory of Open Access Journals (Sweden)

    Jetro Pereira de Oliveira

    2009-04-01

    Full Text Available OBJETIVO: O objetivo deste trabalho foi desenvolver um sistema dosimétrico termoluminescente capaz de avaliar as doses administradas ao reto de pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino. MATERIAIS E MÉTODOS: O material termoluminescente utilizado para a avaliação da dose no reto foi o LiF:Mg,Ti,Na na forma de pó. O pó foi separado em pequenas porções de 34 mg, que foram acomodadas em um tubo capilar. Este tubo foi colocado em uma sonda retal, que era introduzida no reto da paciente. RESULTADOS: As doses administradas ao reto de seis pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino foram avaliadas com dosímetros termoluminescentes e apresentaram boa concordância com os valores planejados, com base em duas radiografias ortogonais da paciente, imagens ântero-posterior e lateral. CONCLUSÃO: O sistema de dosimetria termoluminescente utilizado no presente trabalho é simples e de fácil utilização quando comparado a outros métodos de dosimetria do reto. Ele mostrou-se eficiente na avaliação da dose no reto de pacientes submetidas a braquiterapia de alta taxa de dose para o tratamento do câncer do colo uterino.OBJECTIVE: The present study was aimed at developing a thermoluminescent dosimetric system capable of assessing the doses delivered to the rectum of patients submitted to high-dose-rate brachytherapy for uterine cervix cancer. MATERIALS AND METHODS: LiF:Mg,Ti,Na powder was the thermoluminescent material utilized for evaluating the rectal dose. The powder was divided into small portions (34 mg which were accommodated in a capillary tube. This tube was placed into a rectal probe that was introduced into the patient's rectum. RESULTS: The doses delivered to the rectum of six patients submitted to high-dose-rate brachytherapy for uterine cervix cancer evaluated by means of thermoluminescent dosimeters presented a good

  4. Braquiterapia de alta taxa de dose no tratamento do carcinoma da próstata: análise da toxicidade aguda e do comportamento bioquímico High-dose rate brachytherapy in the treatment of prostate cancer: acute toxicity and biochemical behavior analysis

    Directory of Open Access Journals (Sweden)

    Sérgio Carlos Barros Esteves

    2006-04-01

    Full Text Available OBJETIVO: Analisar a resposta bioquímica nas variáveis volume prostático, valor do antígeno prostático específico (PSA, escores de Gleason, estádio, risco da doença e hormonioterapia. MATERIAIS E MÉTODOS: No período de fevereiro de 1998 a julho de 2001, 46 pacientes com câncer de próstata foram tratados com radioterapia, numa combinação de teleterapia e braquiterapia de alta taxa de dose (BATD. A idade variou de 51 a 79 anos (média de 66,4 anos. O estádio T1c foi o mais freqüente: 30 (65%. O escore de Gleason era abaixo de 7 em 78% dos pacientes. O PSA variou de 3,4 a 33,3, estando abaixo de 10 em 39% das vezes. O volume prostático médio foi de 32,3 cc. Um total de 28% dos pacientes recebeu hormonioterapia. A dose de teleterapia variou de 45 a 50,4 Gy, associada a quatro frações de BATD de 4 Gy. RESULTADOS: O seguimento variou de 6 a 43 meses. Quatro pacientes perderam seguimento e quatro morreram (um por doença. Dos 39 pacientes analisados, 76% apresentaram PSA menor que 1,5. Nenhuma das variáveis analisadas foi estatisticamente significante (p > 0,05 com relação ao controle bioquímico. CONCLUSÃO: A utilização de BATD foi eficiente no tratamento do câncer de próstata e, neste estudo, as variáveis consideradas como fatores prognósticos não interferiram no controle bioquímico.OBJECTIVE: This study focuses on the biochemical response of the following variables: prostate volume, prostate-specific antigen (PSA value, Gleason scores, staging, the risk of the disease, and hormonotherapy. MATERIALS AND METHODS: In the period between February of 1998 and July of 2001, 46 patients with prostate cancer were treated with radiotherapy, in a combination of teletherapy and high-dose rate brachytherapy (HDR. The age ranged from 51 to 79 years (averaging 66.4 years. T1c stage was the most frequent one: 30 (65%. The Gleason score was below 7 in 78% of the patients. PSA ranged from 3.4 to 33.3, being below 10 in 39% of the cases

  5. Proposal of a high dose rate brachytherapy model for in vitro radiobiology studies; Proposta de um modelo de braquiterapia de alta taxa de dose para estudos de radiobiologia in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Geraldo, Jony M.; Nogueira, Luciana B.; Andrade, Lidia M. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Trindade, Cassia [Hospital Luxemburgo, Belo Horizonte, MG (Brazil); Furtado, Clascidia A.; Ladeira, Luiz Orlando, E-mail: jony.marques@mariopenna.org.br [Centro de Desenvolvimento da Tecnologia Nuclear (CTDN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2016-07-01

    The aim of this research was to develop an easy and reproducible approach for experimental HDR brachytherapy allowing in vitro irradiation studies based on clinical parameters. An acrylic platform was designed to attach T25 tissue culture flasks and multi-well tissue culture plates as well as kept the catheters in a fixed position during irradiation. CT images were taken and the irradiation was planned for 550cGy dose applied on adherent tumor cells. Dosimetric measurements were done and all relevant uncertainties were taken into account in order to figure out the correct dose range received by the cells. Tumor cells were irradiated two times over an interval of 24h between irradiations. Proof of concepts of this approach was carried out by biological effects analysis using a radioresistant human epidermoid carcinoma A431 cell line. Cellular proliferation and cell cycle phase were assessed by Trypan blue exclusion assay and DNA content analysis by flow cytometry, respectively. This approach allowed uniform dose distribution around the arrangement in all types of tissue culture plastics evaluated. Corrections due to uncertainties were managed. Regarding in vitro assays there was a significant (p<0.05) decreasing of cellular proliferation rate in irradiated cells. Moreover, increased percentage of cells arrested in G2/M phase (32.3 ± 1.5%) were observed for treated group compared with untreated cells. (author)

  6. Proposal of a high dose rate brachytherapy model for radiobiology studies in vitro; Proposta de um modelo de braquiterapia de alta taxa de dose para estudos de radiobiologia in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Geraldo, Jony M.; Andrade, Lidia M., E-mail: jony.marques@mariopenna.org.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Fisica; Trindade, Cassia [Hospital Luxemburgo, Belo Horizonte, MG (Brazil); Nogueira, Luciana B. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Faculdade de Medicina; Furtado, Clascidia A.; Ladeira, Luiz Orlando [Centro de Desenvolvimento da Tecnologia Nuclear (CTDN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2016-07-01

    The aim of this research was to develop an easy and reproducible approach for experimental HDR brachytherapy allowing in vitro irradiation studies based on clinical parameters. An acrylic platform was designed to attach T25 tissue culture flasks and multi-well tissue culture plates as well as kept the catheters in a fixed position during irradiation. CT images were taken and the irradiation was planned for 550cGy dose applied on adherent tumor cells. Dosimetric measurements were done and all relevant uncertainties were taken into account in order to figure out the correct dose range received by the cells. Tumor cells were irradiated two times over an interval of 24h between irradiations. Proof of concepts of this approach was carried out by biological effects analysis using a radioresistant human epidermoid carcinoma A431 cell line. Cellular proliferation and cell cycle phase were assessed by Trypan blue exclusion assay and DNA content analysis by flow cytometry, respectively. This approach allowed uniform dose distribution around the arrangement in all types of tissue culture plastics evaluated. Corrections due to uncertainties were managed. Regarding in vitro assays there was a significant (p<0.05) decreasing of cellular proliferation rate in irradiated cells. Moreover, increased percentage of cells arrested in G2/M phase (32.3 ± 1.5%) were observed for treated group compared with untreated cells. (author)

  7. Optimization of planar high-dose-rate implants

    International Nuclear Information System (INIS)

    Zwicker, Robert D.; Arthur, Douglas W.; Kavanagh, Brian D.; Mohan, Radhe; Schmidt-Ullrich, Rupert K.

    1999-01-01

    Purpose: Brachytherapy has long been used to deliver localized radiation to the breast and other cancer sites. For interstitial implants, proper source positioning is critical in obtaining satisfactory dose distributions. The present work examines techniques for optimizing source guide placement in high-dose-rate (HDR) biplanar implants, and examines the effects of suboptimal catheter placement. Methods and Materials: Control of individual dwell times in HDR implants allows a high degree of dose uniformity in planes parallel to the implant planes. Biplanar HDR implants can be considered optimized when the dose at the implant center is equal to the dose at the symmetric target boundaries. It is shown that this optimal dose uniformity is achieved when the interplanar separation is related to the target thickness T through the direct proportionality, s = T/√2. To quantify the significance of source positioning, the average dose and a related quantity, equivalent uniform dose (EUD), were calculated inside the treatment volume for two conditions of suboptimal catheter geometry. In one case, the interplanar spacing was varied from 1 cm up to the target thickness T, while a second study examined the effects of off-center placement of the implant planes. Results: Both the average dose and EUD were minimized when the interplanar spacing satisfied the relationship s = T/ √2. EUD, however, was significantly smaller than the average dose, indicating a reduced relative cell killing in the high dose regions near the dwell points. It was also noted that in contrast to the average dose, the EUD is a relatively weak function of catheter misplacement, suggesting that the biological consequences of suboptimal implant geometry may be less significant than is indicated by the increase in average dose. Conclusion: A concise formula can be used to determine the interplanar separation needed for optimal dose uniformity in Manchester-type implants. Deviations from optimal source

  8. WE-DE-201-01: BEST IN PHYSICS (THERAPY): A Fast Multi-Target Inverse Treatment Planning Strategy Optimizing Dosimetric Measures for High-Dose-Rate (HDR) Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Guthier, C [Brigham and Women’s Hospital, Boston, MA (United States); University Medical Center Mannheim, Mannheim (Germany); Harvard Medical School, Boston, MA (United States); Damato, A; Viswanathan, A; Cormack, R [Dana Farber Cancer Institut/Brigham and Women’s Hospital, Boston, MA (United States); Harvard Medical School, Boston, MA (United States); Hesser, J [University Medical Center Mannheim, Mannheim (Germany)

    2016-06-15

    Purpose: Inverse treatment planning (ITP) for interstitial HDR brachytherapy of gynecologic cancers seeks to maximize coverage of the clinical target volumes (tumor and vagina) while respecting dose-volume-histogram related dosimetric measures (DMs) for organs at risk (OARs). Commercially available ITP tools do not support DM-based planning because it is computationally too expensive to solve. In this study we present a novel approach that allows fast ITP for gynecologic cancers based on DMs for the first time. Methods: This novel strategy is an optimization model based on a smooth DM-based objective function. The smooth approximation is achieved by utilizing a logistic function for the evaluation of DMs. The resulting nonconvex and constrained optimization problem is then optimized with a BFGS algorithm. The model was evaluated using the implant geometry extracted from 20 patient treatment plans under an IRB-approved retrospective study. For each plan, the final DMs were evaluated and compared to the original clinical plans. The CTVs were the contoured tumor volume and the contoured surface of the vagina. Statistical significance was evaluated with a one-sided paired Wilcoxon signed-rank test. Results: As did the clinical plans, all generated plans fulfilled the defined DMs for OARs. The proposed strategy showed a statistically significant improvement (p<0.001) in coverage of the tumor and vagina, with absolute improvements of related DMs of (6.9 +/− 7.9)% and (28.2 +/− 12.0)%, respectively. This was achieved with a statistically significant (p<0.01) decrease of the high-dose-related DM for the tumor. The runtime of the optimization was (2.3 +/− 2.0) seconds. Conclusion: We demonstrated using clinical data that our novel approach allows rapid DM-based optimization with improved coverage of CTVs with fewer hot spots. Being up to three orders of magnitude faster than the current clinical practice, the method dramatically shortens planning time.

  9. Postoperative vaginal cuff irradiation using high dose rate remote afterloading: a Phase II clinical protocol

    International Nuclear Information System (INIS)

    Noyes, William R.; Bastin, Kenneth; Edwards, Scott A.; Buchler, Dolores A.; Stitt, Judith A.; Thomadsen, Bruce R.; Fowler, Jack F.; Kinsella, Timothy J.

    1995-01-01

    Purpose: In September 1989, a postoperative Phase II high dose rate (HDR) brachytherapy protocol was started for International Federation of Gynecology and Obstetrics (FIGO) Stage I endometrial adenocarcinoma. This review reports the overall survival, local control, and complication rates for the initial 63 patients treated in this Phase II study. Methods and Materials: High dose rate brachytherapy was delivered using an Iridium-192 HDR remote afterloader. Sixty-three patients were entered into the Phase II protocol, each receiving two vaginal cuff treatments 1 week apart (range 4-12 days) with vaginal ovoids (diameter 2.0-3.0 cm). No patient received adjuvant external beam radiation. A dose of 32.4 Gy in two fractions was prescribed to the ovoid surface in 63 patients. The first three patients treated at our institution received 15, 16.2, and 29 Gy, respectively, to determine acute effects. Results: At a median follow-up of 1.6 years (range 0.75-4.3 years) no patient has developed a vaginal cuff recurrence. One regional recurrence (1.6%) occurred at 1.2 years at the pelvic side wall. This patient is alive and without evidence of disease 7 months after completion of salvage irradiation, which resulted in the only vaginal stenosis (1.6%). Fourteen patients (22%) experienced vaginal apex fibrosis by physical exam, which was clinically symptomatic in four patients. Two patients reported stress incontinence; however, these symptoms were noted prior to their HDR therapy. One patient died 2.4 years after HDR therapy due to cardiovascular disease without evidence of cancer at autopsy. Conclusion: Preliminary results of our phase II HDR vaginal cuff protocol for postoperative FIGO Stage IA, Grade 3 or Stage IB, Grade 1-2 patients demonstrate that 32.4 Gy in two fractions is well tolerated by the vaginal cuff mucosa. Local control appears comparable to our prior experience and others with low dose rate (LDR) brachytherapy. Additional patient accrual and further follow

  10. Comparison of absorbed dose in the cervix carcinoma therapy by brachytherapy of high dose rate using the conventional planning and Monte Carlo simulation; Comparacao da dose absorvida no tratamento do cancer ginecologico por braquiterapia de alta taxa de dose utilizando o planejamento convencional do tratamento e simulacao de Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Aneli Oliveira da

    2010-07-01

    This study aims to compare the doses received for patients submitted to brachytherapy High Dose Rate (HDR) brachytherapy, a method of treatment of the cervix carcinoma, performed in the planning system PLATO BPS with the doses obtained by Monte Carlo simulation using the radiation transport code MCNP 5 and one female anthropomorphic phantom based on voxel, the FAX. The implementation of HDR brachytherapy treatment for the cervix carcinoma consists of the insertion of an intrauterine probe and an intravaginal probe (ring or ovoid) and then two radiographs are obtained, anteroposterior (AP) and lateral (LAT) to confirm the position of the applicators in the patient and to allow the treatment planning and the determination of the absorbed dose at points of interest: rectum, bladder, sigmoid and point A, which corresponds anatomically to the crossings of the uterine arteries with ureters The absorbed doses obtained with the code MCNP 5, with the exception of the absorbed dose in the rectum and sigmoid for the simulation considering a point source of {sup 192}Ir, are lower than the absorbed doses from PLATO BPS calculations because the MCNP 5 considers the chemical compositions and densities of FAX body, not considering the medium as water. When considering the Monte Carlo simulation for a source with dimensions equal to that used in the brachytherapy irradiator used in this study, the values of calculated absorbed dose to the bladder, to the rectum, to the right point A and to the left point A were respectively lower than those determined by the treatment planning system in 33.29, 5.01, 22.93 and 19.04%. These values are almost all larger than the maximum acceptable deviation between patient planned and administered doses (5 %). With regard to the rectum and bladder, which are organs that must be protected, the present results are in favor of the radiological protection of patients. The point A, that is on the isodose of 100%, used to tumor treatment, the results

  11. Análises de protocolos de braquiterapia, por alta taxa de dose, do controle de qualidade de alguns serviços locais, baseados no TG40, TG56 e ARCAL XXX Analysis of the high dose rate brachytherapy protocols of quality assurance programs of some local services, based on TG40, TG56 and ARCAL XXX.

    Directory of Open Access Journals (Sweden)

    Carmen S. Guzmán Calcina

    2001-08-01

    Full Text Available A braquiterapia por alta taxa de dose está recebendo atenção considerável na maioria dos países. Por isso, nos serviços que utilizam este equipamento exige-se que o desenvolvimento de um programa de controle de qualidade seja cada vez mais rigoroso, para garantir não apenas a segurança aos pacientes, mas também aos operadores e demais envolvidos. Este trabalho tem por objetivos fazer um levantamento dos tipos de testes para um equipamento de braquiterapia por alta taxa de dose, propostos pelos protocolos oficiais publicados (TG40, TG56 e ARCAL XXX e avaliar os tipos de testes que atualmente são realizados por alguns serviços de radioterapia, comparando-os com aqueles apresentados nos protocolos citados. Das análises feitas, observou-se que: a quanto aos protocolos oficiais, o TG56 é mais completo que o TG40 e o ARCAL XXX; b quanto às instituições analisadas, estas em geral se basearam no TG56 para elaborar seus próprios protocolos, os quais demonstraram ter também concordância com os outros já citados. Nestes protocolos, a inexistência dos testes anuais foi notada, o que pode ser explicado por sua aparição nas freqüências trimestral e semestral. Do produto deste estudo são apresentadas tabelas dos tipos de testes com suas respectivas freqüências de utilização, das quais um protocolo pode ser inferido para auxiliar na implementação, pelo menos, dos tipos de testes de controle de qualidade básicos e indispensáveis para o equipamento, garantindo, assim, um tratamento adequado aos pacientes e uma melhor segurança ao pessoal envolvido e, conseqüentemente, assegurando a garantia de qualidade na braquiterapia por alta taxa de dose.High dose rate brachytherapy has been increasingly recognized in most countries, and radiotherapy services using this equipment are encouraged to have a very efficient quality assurance program to ensure protection for patients, workers and other personnel involved. The objective of this

  12. Assessment of the implant geometry in fractionated interstitial HDR breast brachytherapy using an electromagnetic tracking system.

    Science.gov (United States)

    Kellermeier, Markus; Fietkau, Rainer; Strnad, Vratislav; Bert, Christoph

    During the partial-breast treatment course by interstitial brachytherapy, electromagnetic tracking (EMT) was applied to measure the implant geometry. Implant-geometry variation, choice of reference data, and three registration methods were assessed. The implant geometry was measured in 28 patients after catheter implantation (EMT bed ), during CT imaging (EMT CT ), and in each of up to n = 9 treatment fractions (EMT F(k), k = 1, 2,… n ). EMT F(k) were registered to the planned implant reconstruction (CT plan ) by using all dwell positions (DPs), the button centers, or three fiducial sensors on the patient's skin. Variation in implant geometry obtained from EMT F(k) was assessed for EMT bed, EMT CT , and CT plan . EMT was used to measure 3932 catheters. A duration of 6.5 ± 1.7 min was needed for each implant measurement (mean, 17 catheters) plus setup of the EMT system. Data registration based on the DP deviated significantly lower than registration on button centers or fiducial sensors. Within a registration group, there was a geometry in high-dose-rate interstitial brachytherapy breast treatments. EMT bed , EMT CT , and CT plan data can serve as reference for assessment of implant changes. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  13. Assessment of uterus position as a surrogate for high-risk clinical target volume with respect to the applicator position for multiple fractions of brachytherapy in cervical cancer.

    Science.gov (United States)

    Cooper, Rachel; Brearley, Elizabeth; Hurmuz, Pervin; Musunuru, Hima Bindu; Richardson, Carolyn; Swift, Sara; Orton, Jane; Bownes, Peter

    2014-12-01

    Hybrid magnetic resonance imaging/computerized tomography (MRI/CT) planning for high-dose-rate (HDR) brachytherapy in cervical cancer with MR/CT fusion for the first fraction followed by CT for fraction 2 and 3 is used at our center. The aim of this study is to evaluate the position of applicator intrauterine tube (IU) in relation to uterine serosa with each fraction of intracavitary high-dose-rate brachytherapy. Position of the applicator relative to uterus was measured from tip of the applicator (IU) to the top of uterus in the plane of IU and perpendicular to IU in anterior, posterior, left and right directions at the tip of IU, mid-point of the IU and 1 cm from the surface of vaginal ring. The mean absolute difference (±95 % confidence interval) between these positions at fraction 2 and 3 was calculated with fraction one as reference. The mean absolute difference (±95 %) of the applicator relative to uterus was 2.7 ± 0.5 mm at the tip, 1.5 ± 4 mm at mid-point and 1.1 ± 0.3 mm at 1 cm from the surface of the ring. This study shows that there is consistency in inter-fraction applicator position relative to uterus apart from at the tip and, therefore, in situations where high-risk clinical target volume (HRCTV) extends towards uterine fundus, MRI should be used for each fraction of brachytherapy planning to accurately define HRCTV.

  14. Monte Carlo dosimetry of the most commonly used {sup 1}92Ir high dose rate brachytherapy sources; Dosimetria Monte Carlo de las fuentes de {sup 1}92Ir de uso mas comun en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Almansa Lopez, J. F.; Torres Donaire, J.; Guerrero Alcalde, R.

    2011-07-01

    The {sup 1}92Ir sources are the most commonly used in high dose rate brachytherapy treatments. The aim of this paper is to provide the characteristic functions established by AAPM Task Group 43 (TG-43) using PENELOPE 2008.1 simulation code for the most widespread {sup 1}92Ir sources in Spain: the Gammamed Plus and Varisource 2000 sources distributed by Varian Medical Systems and the MicroSelectron source distributed by Nucletron BV. Also the new model, mHDR-v2r, has been characterized for MicroSelectron source, including some changes from the previous design, mHDR-v2. The radial dose function, anisotropy function, air-kerma strength, dose rate constant and absorbed dose rate in water tables are in good agreement with available data from other calculations. The obtained values for the dose rate constant have been 1.111 {+-} 0.002 cGy/hU for the Gammamed Plus source, 1.111{+-}0.002 cGy/hU for the MicroSelectron mHDR-v2 source, 1.112 {+-} 0,002 cGy/hU for the MicroSelectron mHDR-v2r source and 1.096 {+-} 0.002 cGy/hU for the Varisource 2000 source. Complete dosimetric results are available in http://bqseeds.sarh.es In this work, results have been obtained for the studied sources with the same calculation conditions and simulations that meet current recommendations. (Author) 28 refs.

  15. Artificial neural network based gynaecological image-guided adaptive brachytherapy treatment planning correction of intra-fractional organs at risk dose variation

    Directory of Open Access Journals (Sweden)

    Ramin Jaberi

    2017-12-01

    Full Text Available Purpose : Intra-fractional organs at risk (OARs deformations can lead to dose variation during image-guided adaptive brachytherapy (IGABT. The aim of this study was to modify the final accepted brachytherapy treatment plan to dosimetrically compensate for these intra-fractional organs-applicators position variations and, at the same time, fulfilling the dosimetric criteria. Material and methods : Thirty patients with locally advanced cervical cancer, after external beam radiotherapy (EBRT of 45-50 Gy over five to six weeks with concomitant weekly chemotherapy, and qualified for intracavitary high-dose-rate (HDR brachytherapy with tandem-ovoid applicators were selected for this study. Second computed tomography scan was done for each patient after finishing brachytherapy treatment with applicators in situ. Artificial neural networks (ANNs based models were used to predict intra-fractional OARs dose-volume histogram parameters variations and propose a new final plan. Results : A model was developed to estimate the intra-fractional organs dose variations during gynaecological intracavitary brachytherapy. Also, ANNs were used to modify the final brachytherapy treatment plan to compensate dosimetrically for changes in ‘organs-applicators’, while maintaining target dose at the original level. Conclusions : There are semi-automatic and fast responding models that can be used in the routine clinical workflow to reduce individually IGABT uncertainties. These models can be more validated by more patients’ plans to be able to serve as a clinical tool.

  16. Transperineal high-dose-rate interstitial radiation therapy in the management of gynecologic malignancies

    Energy Technology Data Exchange (ETDEWEB)

    Itami, Jun; Hara, Ryuseke; Kozuka, Takuyou; Yamashita, Hideomi; Nakajima, Kaori; Shibata, Kouji; Abe, Yoshihisa; Fuse, Masashi; Ito, Masashi [International Medical Center of Japan, Tokyo (Japan). Dept. of Radiation Therapy and Oncology

    2003-11-01

    Background: High-dose-rate interstitial radiation therapy is a newly introduced modality, and its role in the management of gynecologic malignancies remains to be studied. Clinical experience in high-dose-rate interstitial radiation therapy was retrospectively investigated. Patients and Methods: Eight patients with primary and nine with recurrent gynecologic malignancies underwent high-dose-rate interstitial radiation therapy with/without external-beam irradiation. Fractional dose of the high-dose-rate interstitial radiation therapy ranged between 4 and 6 Gy with total doses of 15-54 Gy. Interstitial irradiation was performed twice daily with an interval of > 6 h. Results: 2-year local control rate was 75% for primary treatment and 47% for treatment of recurrence (p = 0.46). Maximum tumor size had a statistically significant impact on local control (p < 0.002). Grade 2 and 4 late complications were seen in five patients, and the incidence was significantly higher in patients with a larger volume enclosed by the prescribed fractional dose of high-dose-rate interstitial radiation therapy. The incidence of grade 2 and 4 complications at 18 months was 78% and 0% with a volume > 100 cm{sup 3} and {<=} 100 cm{sup 3}, respectively (p < 0.04). Conclusion: Although high-dose-rate interstitial radiation therapy is a promising modality, it must be applied cautiously to patients with bulky tumors because of the high incidence of serious complications. (orig.)

  17. Breast conserving treatment of breast carcinoma T2 ({<=} 4 cm) and T3 by neoadjuvant chemotherapy, quadrantectomy, high dose rate brachytherapy as a boost, external beam radiotherapy and adjuvant chemotherapy: local control and overall survival analysis; Tratamento conservador do cancer de mama T2 ({<=} 4 cm) e T3 por quimioterapia neoadjuvante, quadrantectomia, braquiterapia com alta taxa de dose como reforco de dose, teleterapia complementar e quimioterapia adjuvante: analise de controle local e sobrevida global

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Celia Regina; Miziara Filho, Miguel Abrao; Fogaroli, Ricardo Cesar; Baraldi, Helena Espindola; Pellizzon, Antonio Cassio Assis; Pelosi, Edilson Lopes [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Radioterapia], e-mail: celiarsoares@terra.com.br; Fristachi, Carlos Elias [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Onco-Ginecologia e Mastologia; Paes, Roberto Pinto [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil)

    2008-12-15

    Objective: to assess the treatment of breast cancer T2 ({<=} 4 cm) and T3 through neoadjuvant chemotherapy, quadrantectomy and high dose rate brachytherapy as a boost, complementary radiotherapy and adjuvant chemotherapy, considering local control and overall survival. Material and method: this clinical prospective descriptive study was based on the evaluation of 88 patients ranging from 30 to 70 years old, with infiltrating ductal carcinoma, clinical stage IIb and IIIa, responsive to the neoadjuvant chemotherapy, treated from June/1995 to December/2006. Median follow-up was 58 months. Using clinical methods the tumor was evaluated before and after three or four cycles of chemotherapy based on anthracyclines. Overall survival and local control were assessed according to Kaplan-Meier methodology. Results: Local control and overall survival in five years were 90% and 73.5%, respectively. Conclusion: local control and overall survival were comparable to other forms of treatment. (author)

  18. Development of computerized dose planning system and applicator for high dose rate remote afterloading irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, T. J. [Keimyung Univ., Taegu (Korea); Kim, S. W. [Fatima Hospital, Taegu (Korea); Kim, O. B.; Lee, H. J.; Won, C. H. [Keimyung Univ., Taegu (Korea); Yoon, S. M. [Dong-a Univ., Pusan (Korea)

    2000-04-01

    To design and fabricate of the high dose rate source and applicators which are tandem, ovoids and colpostat for OB/Gyn brachytherapy includes the computerized dose planning system. Designed the high dose rate Ir-192 source with nuclide atomic power irradiation and investigated the dose characteristics of fabricated brachysource. We performed the effect of self-absorption and determining the gamma constant and output factor and determined the apparent activity of designed source. he automated computer planning system provided the 2D distribution and 3D includes analysis programs. Created the high dose rate source Ir-192, 10 Ci(370GBq). The effective attenuation factor from the self-absorption and source wall was examined to 0.55 of the activity of bare source and this factor is useful for determination of the apparent activity and gamma constant 4.69 Rcm{sup 2}/mCi-hr. Fabricated the colpostat was investigated the dose distributions of frontal, axial and sagittal plane in intra-cavitary radiation therapy for cervical cancer. The reduce dose at bladder and rectum area was found about 20 % of original dose. The computerized brachytherapy planning system provides the 2-dimensional isodose and 3-D include the dose-volume histogram(DVH) with graphic-user-interface mode. emoted afterloading device was built for experiment of created Ir-192 source with film dosimetry within {+-}1 mm discrepancy. 34 refs., 25 figs., 11 tabs. (Author)

  19. Characterization of TLD-100 in powders for dosimetric quality control of {sup 192} Ir sources used in brachytherapy of high dose rate; Caracterizacion de TLD-100 en polvo para control de calidad dosimetrico de fuentes de Ir{sup 192} usadas en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P

    2007-07-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D{sub w} for the energy of: {sup 60}Co, {sup 137C}s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the {sup 192}Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of {sup 192}Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the {sup 60}Co for D{sub w}, using a secondary standard ionization chamber PTW N30013 calibrated in D{sub w} by the National Research Council (NRC, Canada). AAPM TG-43 for D{sub w} in terms of the strength kerma Sk, calibrating this last one quantity for the {sup 137}Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D{sub w} start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R{sub TLD} vs D{sub w}: For the energy of {sup 60}Co, {sup 137}Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F{sub s}) for each energy corresponds to the slope of the CC, v. The F{sub s} for the two {sup 192}Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of

  20. Cirurgia conservadora, radioterapia externa e reforço de dose com braquiterapia de alta taxa de dose: uma nova perspectiva no tratamento de sarcomas de partes moles do adulto Limb-sparing surgery, external beam radiotherapy and boost with high-dose rate brachytherapy: a new perspective for the treatment of soft tissue sarcomas in adults

    Directory of Open Access Journals (Sweden)

    Antonio Cássio Assis Pellizzon

    2002-03-01

    Full Text Available OBJETIVO: Avaliar a influência no controle local de pacientes adultos e portadores de sarcoma de partes moles em extremidades e submetidos a cirurgia conservadora do membro, com braquiterapia de alta taxa de dose (BATD como reforço para a radioterapia externa (RT. MATERIAL E MÉTODOS: Foram avaliados 16 pacientes tratados, de 1993 até 1999. A RT foi utilizada com finalidade pré ou pós-operatória (30--55 Gy e BATD com dose de 18--36 Gy (fx 3--6 Gy BID. Com base no modelo linear quadrático calculou-se a dose efetiva biológica ("biological effective dose" - BED para o tumor e comparou-se seu valor a dados da literatura internacional, que utiliza tratamentos com RT e braquiterapia de baixa taxa de dose (BBTD. RESULTADOS: Os valores médios e medianos da BED para os sarcomas de partes moles foram de 78,5 Gy7 e 80 Gy7. A análise univariada mostrou que a BED para o tumor, quando utilizada BATD, era semelhante ao valor de 83 Gy7 quando utilizada BBTD (p = 0,008. As taxas de controle local, sobrevida livre de doença e sobrevida global atuarial em cinco anos foram de 83,2%, 75% e 93,7%, respectivamente. CONCLUSÕES: A BATD, quando utilizada como método complementar no reforço de dose da RT no tratamento conservador dos sarcomas de partes moles, apresenta taxas de controle local equiparáveis às da literatura internacional; no entanto, estudos com número maior de pacientes e período maior de seguimento são ainda necessários para determinar o verdadeiro potencial da BATD em substituir a BBTD.PURPOSE: To evaluate the influence on local control in adult patients with soft tissue sarcomas of the limbs that underwent limb-sparing surgery and high-dose rate brachytherapy (HDRB in association with teletherapy. MATERIAL AND METHODS: Sixteen patients treated from 1993 to 1999 were reviewed. Teletherapy was used pre- or postoperatively (30--55 Gy in association with HDRB in a dose range of 18--36 Gy (fx 3--6 Gy BID. The linear quadratic model was

  1. In phantom calibration of a high dose rate remote afterloading device

    International Nuclear Information System (INIS)

    Alfonso, R.; Tolede, P.; Pich, V.

    1995-01-01

    The high dose-rate (HDR) brachytherapy in Cuba is based on soviet made devices type AGAT-V. In order to calibration one of these for clinical use a method based of the different measurement of absorbed dose at the reference point B in a paraffin phantom was developed. The results of the calibration are shown. From these results an analysis was made of the effective doses to prescription point a considering the Lineal-Quadratic model. The clinical results by using the AGAT-V device are displayed in a comparative way

  2. High-Dose-Rate Monotherapy for Localized Prostate Cancer: 10-Year Results

    Energy Technology Data Exchange (ETDEWEB)

    Hauswald, Henrik; Kamrava, Mitchell R.; Fallon, Julia M.; Wang, Pin-Chieh; Park, Sang-June; Van, Thanh; Borja, Lalaine; Steinberg, Michael L.; Demanes, D. Jeffrey, E-mail: JDemanes@mednet.ucla.edu

    2016-03-15

    Purpose: High-dose-rate (HDR) brachytherapy was originally used with external beam radiation therapy (EBRT) to increase the dose to the prostate without injuring the bladder or rectum. Numerous studies have reported HDR brachytherapy is safe and effective. We adapted it for use without EBRT for cases not requiring lymph node treatment. Patients and Methods: We entered the patient demographics, disease characteristics, and treatment parameters into a prospective registry and serially added follow-up data for 448 men with low-risk (n=288) and intermediate-risk (n=160) prostate cancer treated from 1996 to 2009. Their median age was 64 years (range 42-90). The median prostate-specific antigen (PSA) level was 6.0 ng/mL (range 0.2-18.2). The Gleason score was ≤6 in 76% and 7 in 24%. The median dose was 43.5 Gy in 6 fractions. The clinical and biochemical disease control and survival rates were calculated. Adverse events were graded according to the Common Toxicity Criteria of Adverse Events. Results: The median follow-up period was 6.5 years (range 0.3-15.3). The actuarial 6- and 10-year PSA progression-free survival was 98.6% (95% confidence interval [CI] 96.9%-99.4%) and 97.8% (95% CI 95.5%-98.9%). Overall survival at 10 years was 76.7% (95% CI 69.9%-82.2%). The local control, distant metastasis-free survival, and cause-specific survival were 99.7% (95% CI 97.9%-99.9%), 98.9% (95% CI 96.3%-99.7%), and 99.1% (95% CI 95.8%-99.8%). T stage, initial PSA level, Gleason score, National Comprehensive Cancer Network risk group, patient age, and androgen deprivation therapy did not significantly correlate with disease control or survival. No late grade 3 to 4 rectal toxicities developed. Late grade 3 to 4 genitourinary toxicity occurred in 4.9% (grade 3 in 4.7%). Conclusions: HDR monotherapy is a safe and highly effective treatment of low- and intermediate-risk prostate cancer.

  3. Dosimetric advancement of high-dose-rate after-loading 192Ir source

    International Nuclear Information System (INIS)

    Zhang Shuxu; Li Wenhua; Xu Hairong

    2004-01-01

    High-dose-rate (HDR) 192 Ir source is a nuclide commonly used in the brachytherapy system. The basic dosimetry data of the near source area is usually measured by pin ion chambers or TLD techniques, but these methods have a lower spatial resolution than Electron spin resonance (ESR) dosimetry which has a spatial resolution of 156 μm, and the Monte Carlo photon transport simulations are taken as the golden standard of those measures. The precision in two-dimensional dose distribution measured by GafChromic film is reported to be 1.0%. In vivo dosimetry using TLD during HDR intracavitary after-loading brachytherapy is a good predictor of late rectal complications. The accuracy of magnetic resonance imaging (MRI) Fricke-gel dosimetry for three-dimensional dose distribution is about 2.5% with a spatial resolution of 1.56 mm. The optical computed tomography polymer gel dosimetry has a unique advance than MRI gel dosimetry

  4. High-dose-rate iridium-192 afterloading therapy combined with external beam radiotherapy for T1c-T3bN0M0 prostate cancer.

    Science.gov (United States)

    Jo, Yoshimasa; Hiratsuka, Junichi; Fujii, Tomohiro; Takenaka, Atsushi; Fujisawa, Masato

    2004-09-01

    To determine the efficacy of radiotherapy (RT) for T1c-T3bN0M0 prostate cancer in a prospective clinical trial of concurrent external beam RT and fractionated iridium-192 high-dose-rate brachytherapy. Included in the study were 98 patients with T1c-T3bN0M0 prostate cancer who were diagnosed between October 1997 and September 2002 and underwent high-dose-rate brachytherapy with external beam RT. Treatment consisted of external beam RT (four ports) to the prostate of 16 fractions of 2.3 Gy to a total dose of 36.8 Gy and high-dose-rate brachytherapy of 4 fractions of 6.0 Gy within 30 hours to a total dose of 24.0 Gy. No patient received adjuvant hormonal therapy after RT. The most recent prostate-specific antigen level was 0.0 to 3.9 ng/mL (median 0.4). Seven patients (7.1%) developed recurrence and treatment was considered a failure (bone metastasis in two and biochemical failure in five). The overall biochemical disease-free survival (bDFS) rate was 95.9% at 2 years and 92.9% at 5 years. The bDFS rate by T stage was 98.6% at 2 years and 95.9% at 5 years for Stage T1c-T2b and 88.0% and 84.0% for Stage T3a-b, respectively (P = 0.047). The 2-year and 5-year bDFS rate was better in patients with an initial prostate-specific antigen level of less than 20 ng/mL compared with 20 ng/mL or greater (98.6% and 97.1% versus 93.1% and 82.8%, respectively, P = 0.0261). Acute toxicity was mild to moderate (Radiation Therapy Oncology Group grade 1-2) and consisted of cystourethritis or proctitis in 29 (29.6%) of 98 patients. With a low complication rate and satisfactory bDFS rates, this combination therapy can be considered an alternative method for clinical Stage T1c-T3b prostate cancer and is expected to improve patient quality of life. Additional long-term follow-up is needed to confirm this treatment.

  5. Calibration procedure for thermoluminescent dosemeters in water absorbed doses for Iridium-192 high dose rate sources

    International Nuclear Information System (INIS)

    Reyes Cac, Franky Eduardo

    2004-10-01

    Thermoluminescent dosimeters are used in brachytherapy services quality assurance programs, with the aim of guaranteeing the correct radiation dose supplied to cancer patients, as well as with the purpose of evaluating new clinical procedures. This work describes a methodology for thermoluminescent dosimeters calibration in terms of absorbed dose to water for 192 Ir high dose rate sources. The reference dose used is measured with an ionization chamber previously calibrated for 192 Ir energy quality, applying the methodology proposed by Toelli. This methodology aims to standardizing the procedure, in a similar form to that used for external radiotherapy. The work evolves the adaptation of the TRS-277 Code of the International Atomic Energy Agency, for small and big cavities, through the introduction for non-uniform experimental factor, for the absorbed dose in the neighborhood of small brachytherapy sources. In order to simulate a water medium around the source during the experimental work, an acrylic phantom was used. It guarantees the reproducibility of the ionization chamber and the thermoluminescent dosimeter's location in relation to the radiation source. The values obtained with the ionization chamber and the thermoluminescent dosimeters, exposed to a 192 Ir high dose rate source, were compared and correction factors for different source-detector distances were determined for the thermoluminescent dosimeters. A numeric function was generated relating the correction factors and the source-detector distance. These correction factors are in fact the thermoluminescent dosimeter calibration factors for the 192 Ir source considered. As a possible application of this calibration methodology for thermoluminescent dosimeters, a practical range of source-detector distances is proposed for quality control of 192 Ir high dose rate sources. (author)

  6. Radioterapia adjuvante no tratamento do câncer de endométrio: experiência com a associação de radio-terapia externa e braquiterapia de alta taxa de dose Adjuvant radiation therapy for the treatment of endometrial cancer: experience with combination of external radiation therapy and high-dose rate brachytherapy

    Directory of Open Access Journals (Sweden)

    Michael Jenwei Chen

    2005-12-01

    Full Text Available OBJETIVO: Analisar, retrospectivamente, os resultados da radioterapia externa (RT combinada a braquiterapia de alta taxa de dose (BATD, adjuvantes à cirurgia para o carcinoma de endométrio. MATERIAIS E MÉTODOS: Avaliamos 141 pacientes tratados com RT e BATD adjuvantes à cirurgia, no período de janeiro de 1993 a janeiro de 2001. RT pélvica foi realizada com dose mediana de 45 Gy, e BATD realizada na dose mediana de 24 Gy, em quatro inserções semanais de 6 Gy. A idade mediana das pacientes foi de 63 anos e a distribuição por estádio clínico (EC foi: EC I (FIGO, 52,4%; EC II, 13,5%; EC III, 29,8%; EC IV, 4,3%. RESULTADOS: Com seguimento mediano de 53,7 meses, a sobrevida livre de doença (SLD em cinco anos foi: EC I, 88,0%; EC II, 70,8%; EC III, 55,1%; EC IV, 50,0% (p = 0,0003. A sobrevida global em cinco anos foi: EC I, 79,6%; EC II, 74,0%; EC III, 53,6%; EC IV, 100,0% (p = 0,0062. Fatores que influíram na SLD foram grau histológico e histologia seropapilífera. Dos 33 casos que apresentaram recidiva da doença, em 13 (9,2% esta ocorreu na pelve, vagina ou cúpula vaginal. RT + BATD do fundo vaginal permitiram o controle da doença em 90,8% dos casos. CONCLUSÃO: A RT exerce papel fundamental no controle loco-regional do câncer de endométrio e permite excelentes taxas de cura nos estádios iniciais. Para os estádios mais avançados, a falha terapêutica tende a ser a distância, sugerindo a necessidade de complementação terapêutica sistêmica, com introdução de novas modalidades de tratamento, em particular a quimioterapia.OBJECTIVE: To review the results of adjuvant external beam radiation therapy (EBRT combined with high-dose rate brachytherapy (HDR-BT for the treatment of endometrial carcinoma. MATERIALS AND METHODS: We retrospectively evaluated 141 patients treated with EBRT and HDR-BT after surgery between January 1993 and January 2001. EBRT was performed with a median dose of 45 Gy, and HDR-BT was performed with a

  7. Treatment of carcinoma of uterine cervix with high-dose-rate intracavitary irradiation using Ralstron

    International Nuclear Information System (INIS)

    Suh, C.O.; Kim, G.E.; Loh, J.J.K.

    1988-01-01

    From May 1979 through December 1981, a total of 530 patients with carcinoma of the uterine cervix were treated with radiation therapy with curative intent. Of the 530 patients, 365 were treated with a high-dose-rate remote-controlled afterloading system (RALS) using a cobalt source, and 165 patients received a low dose rate using a radium source. External pelvic irradiation with a total of 40-50 Gy to the whole pelvis followed by intracavitary radiation (ICR) with a total dose of 30-39 Gy in ten to 13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rate with high-dose-rate ICR by stage was as follows: stage I:82.7% (N = 19) stage II:69.6% (N = 184), and stage III:52.2% (N = 156). The above results were comparable with those with conventional low-dose-rate ICR treatment, and late complications were far less. The application of high-dose-rate ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually none as compared with that of low-dose-rate ICR. Within a given period of time, more patients can be treated with high-dose-rate ICR because of the short treatment time. The authors therefore conclude that high-dose-rate ICR is suitable for a cancer center where a large number of patients are to be treated

  8. Breast conserving treatment of locally advanced carcinoma T2 and T3 after neoadjuvant chemotherapy followed by quadrantectomy and high dose-rate brachytherapy, as a boost, complementary teletherapy and adjuvant chemotherapy; Tratamento conservador dos carcinomas de mama localmente avancados T2 e T3, apos quimioterapia neoadjuvante, com quadrantectomia e braquiterapia de alta taxa de dose como reforco de dose, teleterapia complementar e quimioterapia adjuvante

    Energy Technology Data Exchange (ETDEWEB)

    Fristachi, Carlos Elias [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Onco-Ginecologia e Mastologia]. E-mail: cefristachi@uol.com.br; Miziara Filho, Miguel Abrao; Soares, Celia Regina; Fogaroli, Ricardo Cesar; Pelosi, Edilson Lopes; Martins, Homero Lavieri Martins [Instituto do Cancer Dr. Arnaldo Vieira de Carvalho (ICAVC), Sao Paulo, SP (Brazil). Servico de Radioterapia; Baracat, Fausto Farah [Hospital do Servidor Publico Estadual de Sao Paulo (HSPE), SP (Brazil). Servico de Ginecologia e Mastologia; Piato, Sebastiao [Irmandade da Santa Casa de Misericordia de Sao Paulo, SP (Brazil). Dept. de Obstetricia e Ginecologia (DOGI)

    2005-07-01

    Objective: to assess the treatment of breast cancer T2 and T3(T > = 4 cm), through neoadjuvant chemotherapy, quadrantectomy and high-dose-rate (HDR) brachytherapy as a boost, complementary radiotherapy and adjuvant chemotherapy, considering its method problems, its esthetics results, the aspect of local control, overall survival, and disease-free survival. Patients and method: this clinical prospective descriptive study was based on the evaluation of 26 patients ranging from 30 to 70 years old, with infiltrating ductal carcinoma, clinical stage IIB and IIIA, responsive to the neoadjuvant chemotherapy. Early and late radiotherapy complications were evaluated according to the criteria established by the RTOG/EORTC (Radiotherapy and Oncology Group /European Organization for Research and Treatment of Cancer) groups. Esthetics evaluation was done in accordance with the criteria set by a plastic surgeon. Local control was evaluated by clinical method, mammography and ultrasonography. Overall survival (OS) and the disease-free survival (DFS) were assessed according to Kaplan-Meier methodology. All the patients were treated at the Dr. Arnaldo Vieira de Carvalho Cancer Institute, from June/1995 to November/2001, and evaluated in March, 2002, with median follow-up of 28.7 months. Results: early complications were observed in 8 patients (30.6%). Two patients were classified as G3 and G4 (RTOG/EORTC). Six patients had late complications and three of them (11.5%) were classified as G3 and G4. One patient (3.8%) had local recurrence, 64 months after having local treatment. Esthetics results were considered good or regular in 16 patients (60.5%) out of 24 patients who were examined. Overall survival and disease-free survival in 24, 36 and 60 months were 100%, 92.3% and 83.1% respectively. Conclusion: early and late radiotherapy complications were considerate high when compared to literature, but esthetic results were considered acceptable. RL, OS and DFS were comparable to other

  9. Strategies and technical aspects of endobronchial high dose rate irradiation in the treatment of malignant airway occlusion

    International Nuclear Information System (INIS)

    Muto, Paolo; Ravo, Vincenzo

    1996-01-01

    Objectives: The combination of external beam radiotherapy (EBRT) and High Dose Rate Brachytherapy (HDRBT) in a definitive approach to these patients is proposed. Moreover we try to determine the maximal acutely tolerable dose of HDRBT combined with EBRT and to search the optimal dose schedule using different fractionations. Material and Methods: From January 1992 to September 1995 we treated 165 patients with external beam radiotherapy with concomitant HDR endobronchial brachytherapy. Patients selection criteria were: biopsy proved histology (non small cell cancers), Stage IIIa-IIIb-IV, KPS > 60, expectance of life> 3 months, presence of cough and/or dyspnea, haemoptysis, obstructive pneumonia. EBRT was performed using a 15 Mv linear accelerator and delivering 60 Gy to the tumor bed and 50 Gy for mediastinum with or without treating the supraclavicular fossae. In 38 patients (Group A) we delivered, with HDRBT, 10 Gy in 1 fraction with a dose that was calculated at 1 cm from the central axis of the endobronchial catheter. In 47 patients (Group B) HDRBT dose was of 7 Gy in 2 fractions always at 1 cm. In 80 patients (Group C) the dose was of 5 Gy in 3 fractions. In 20 patients of this group the dose was calculated at 1 cm and in 60 it was calculated at 0,5 cm from the central axis. Group A treatment was performed before starting EBRT. Group B received brachytherapy at the beginning and at the end of the EBRT treatment. Group C was treated every 15 fractions of EBRT (timing 0,15,30). Totally our group has performed 382 treatments. Results: Follow up is in the range of 5-36 months (with 151/165 evaluable patients). Mean survival from diagnosis of 10.3 months and mean survival from last HDRBT of 9.5 months. The symptomatic response rate is of 90% for dyspnea, 82 % for cough, 94% for emoptysis and of 90 % for obstructive pneumonia. We proved it at the 6 months bronchoscopy in (27(35)) patients evaluable of Group A, in(22(44)) evaluable of Group B and in(18(62)) evaluable

  10. Safety handling manual for high dose rate remote afterloading system

    International Nuclear Information System (INIS)

    1999-01-01

    This manual is mainly for safety handling of 192 Ir-RALS (remote afterloading system) of high dose rate and followings were presented: Procedure and document format for the RALS therapy and for handling of its radiation source with the purpose of prevention of human errors and unexpected accidents, Procedure for preventing errors occurring in the treatment schedule and operation, and Procedure and format necessary for newly introducing the system into a facility. Consistency was intended in the description with the quality assurance guideline for therapy with small sealed radiation sources made by JASTRO (Japan Society for Therapeutic Radiology and Oncology). Use of the old type 60 Co-RALS was pointed out to be a serious problem remained and its safety handling procedure was also presented. (K.H.)

  11. A review of the clinical experience in pulsed dose rate brachytherapy.

    Science.gov (United States)

    Balgobind, Brian V; Koedooder, Kees; Ordoñez Zúñiga, Diego; Dávila Fajardo, Raquel; Rasch, Coen R N; Pieters, Bradley R

    2015-01-01

    Pulsed dose rate (PDR) brachytherapy is a treatment modality that combines physical advantages of high dose rate (HDR) brachytherapy with the radiobiological advantages of low dose rate brachytherapy. The aim of this review was to describe the effective clinical use of PDR brachytherapy worldwide in different tumour locations. We found 66 articles reporting on clinical PDR brachytherapy including the treatment procedure and outcome. Moreover, PDR brachytherapy has been applied in almost all tumour sites for which brachytherapy is indicated and with good local control and low toxicity. The main advantage of PDR is, because of the small pulse sizes used, the ability to spare normal tissue. In certain cases, HDR resembles PDR brachytherapy by the use of multifractionated low-fraction dose.

  12. Increasing Fractional Doses Increases the Probability of Benign PSA Bounce in Patients Undergoing Definitive HDR Brachytherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hauck, Carlin R.; Ye, Hong; Chen, Peter Y.; Gustafson, Gary S.; Limbacher, Amy; Krauss, Daniel J., E-mail: Daniel.krauss@beaumont.edu

    2017-05-01

    Purpose: Prostate-specific antigen (PSA) bounce is a temporary elevation of the PSA level above a prior nadir. The purpose of this study was to determine whether the frequency of a PSA bounce following high-dose-rate (HDR) interstitial brachytherapy for the treatment of prostate cancer is associated with individual treatment fraction size. Methods and Materials: Between 1999 and 2014, 554 patients underwent treatment of low- or intermediate-risk prostate cancer with definitive HDR brachytherapy as monotherapy and had ≥3 subsequent PSA measurements. Four different fraction sizes were used: 950 cGy × 4 fractions, 1200 cGy × 2 fractions, 1350 cGy × 2 fractions, 1900 cGy × 1 fraction. Four definitions of PSA bounce were applied: ≥0.2, ≥0.5, ≥1.0, and ≥2.0 ng/mL above the prior nadir with a subsequent return to the nadir. Results: The median follow-up period was 3.7 years. The actuarial 3-year rate of PSA bounce for the entire cohort was 41.3%, 28.4%, 17.4%, and 6.8% for nadir +0.2, +0.5, +1.0, and +2.0 ng/mL, respectively. The 3-year rate of PSA bounce >0.2 ng/mL was 42.2%, 32.1%, 41.0%, and 59.1% for the 950-, 1200-, 1350-, and 1900-cGy/fraction levels, respectively (P=.002). The hazard ratio for bounce >0.2 ng/mL for patients receiving a single fraction of 1900 cGy compared with those receiving treatment in multiple fractions was 1.786 (P=.024). For patients treated with a single 1900-cGy fraction, the 1-, 2-, and 3-year rates of PSA bounce exceeding the Phoenix biochemical failure definition (nadir +2 ng/mL) were 4.5%, 18.7%, and 18.7%, respectively, higher than the rates for all other administered dose levels (P=.025). Conclusions: The incidence of PSA bounce increases with single-fraction HDR treatment. Knowledge of posttreatment PSA kinetics may aid in decision making regarding management of potential biochemical failures.

  13. Increasing Fractional Doses Increases the Probability of Benign PSA Bounce in Patients Undergoing Definitive HDR Brachytherapy for Prostate Cancer.

    Science.gov (United States)

    Hauck, Carlin R; Ye, Hong; Chen, Peter Y; Gustafson, Gary S; Limbacher, Amy; Krauss, Daniel J

    2017-05-01

    Prostate-specific antigen (PSA) bounce is a temporary elevation of the PSA level above a prior nadir. The purpose of this study was to determine whether the frequency of a PSA bounce following high-dose-rate (HDR) interstitial brachytherapy for the treatment of prostate cancer is associated with individual treatment fraction size. Between 1999 and 2014, 554 patients underwent treatment of low- or intermediate-risk prostate cancer with definitive HDR brachytherapy as monotherapy and had ≥3 subsequent PSA measurements. Four different fraction sizes were used: 950 cGy × 4 fractions, 1200 cGy × 2 fractions, 1350 cGy × 2 fractions, 1900 cGy × 1 fraction. Four definitions of PSA bounce were applied: ≥0.2, ≥0.5, ≥1.0, and ≥2.0 ng/mL above the prior nadir with a subsequent return to the nadir. The median follow-up period was 3.7 years. The actuarial 3-year rate of PSA bounce for the entire cohort was 41.3%, 28.4%, 17.4%, and 6.8% for nadir +0.2, +0.5, +1.0, and +2.0 ng/mL, respectively. The 3-year rate of PSA bounce >0.2 ng/mL was 42.2%, 32.1%, 41.0%, and 59.1% for the 950-, 1200-, 1350-, and 1900-cGy/fraction levels, respectively (P=.002). The hazard ratio for bounce >0.2 ng/mL for patients receiving a single fraction of 1900 cGy compared with those receiving treatment in multiple fractions was 1.786 (P=.024). For patients treated with a single 1900-cGy fraction, the 1-, 2-, and 3-year rates of PSA bounce exceeding the Phoenix biochemical failure definition (nadir +2 ng/mL) were 4.5%, 18.7%, and 18.7%, respectively, higher than the rates for all other administered dose levels (P=.025). The incidence of PSA bounce increases with single-fraction HDR treatment. Knowledge of posttreatment PSA kinetics may aid in decision making regarding management of potential biochemical failures. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Radiolesão vascular como efeito deletério da braquiterapia intra-arterial com dose elevada de Samário-153 em coelhos hipercolesterolêmicos Vascular radiolesion as a deleterious effect of high-dose-rate intraarterial brachytherapy with Samarium-153 in hypercholesterolemic rabbits

    Directory of Open Access Journals (Sweden)

    Dalton Bertolim Précoma

    2006-10-01

    Full Text Available OBJETIVO: Este estudo tem por objetivo avaliar as alterações vasculares morfológicas e morfométricas induzidas pela braquiterapia com Samário-153 (153 Sm em coelhos hipercolesterolêmicos, com doses elevadas. MÉTODOS: Foram analisados 43 coelhos hipercolesterolêmicos, brancos, da raça New Zealand, e o total de 86 artérias ilíacas submetidas a lesão por balão de angioplastia. Divididos em três grupos: dois (GI irradiados com as doses de 15Gy (n=14 e 60Gy (n=36 e um grupo controle (n=36. Foram realizadas avaliação histológica morfométrica e análise histológica qualitativa para análise tecidual. RESULTADOS: Foram observadas uma redução significativa da neoproliferação intimal (NPI no GI 15 Gy (pOBJECTIVE: This study was designed to evaluate vascular morphological and morphometric changes induced by brachytherapy with samarium-153 (Sm-153 at high doses in hypercholesterolemic rabbits. METHODS: Forty-three New Zealand White hypercholesterolemic rabbits were analyzed, and the total of 86 iliac arteries underwent balloon angioplasty injury. The rabbits were divided into three different groups: two irradiation groups (IG assigned to 15 Gy (n=14 and 60 Gy (n=36 irradiation doses, respectively, and a control group (n = 36. Histomorphometric and qualitative histological analyses were performed for tissue evaluation. RESULTS: Significant reductions were found in neointimal proliferation (NIP (p< 0.0001, media area (MA (p<0.0001 and percent stenosis (p<0.0001 in the 15-Gy IG, compared to the other groups. The 60-Gy IG had the higher rate of NIP, increase in media and vessel areas (VA and percent stenosis. The 60-Gy IG also showed the greatest number of xanthomatous cells (60-Gy IG: 86.11% and 15-Gy IG: 14.29%, p<0.0001 and the highest amount of hyaline amorphous tissue (60-Gy IG:58.33% and 15-Gy IG:0%, p=0.0001 and vascular proliferation (60-Gy IG:30.56% and 15-Gy IG:0%, p=0.0221. No statistically significant differences were found

  15. Impact of source position on high-dose-rate skin surface applicator dosimetry.

    Science.gov (United States)

    Jeong, Jeho; Barker, Christopher A; Zaider, Marco; Cohen, Gil'ad N

    2016-01-01

    Skin surface dosimetric discrepancies between measured and treatment planning system predicted values were traced to source position sag inside the applicator and to source transit time. We quantified their dosimetric impact and propose corrections for clinical use. We measured the dose profiles from the Varian Leipzig-style high-dose-rate (HDR) skin applicator, using EBT3 film, photon diode, and optically stimulated luminescence dosimeter for three different GammaMedplus HDR afterloaders. The measured dose profiles at several depths were compared with BrachyVision Acuros calculated profiles. To assess the impact of the source sag, two different applicator orientations were considered. The dose contribution during source transit was assessed by comparing diode measurements using an HDR timer and an electrometer timer. Depth doses measured using the three dosimeters were in good agreement, but were consistently higher than the Acuros dose calculations. Measurements with the applicator face up were significantly (exceeding 10%) lower than those in the face down position, due to source sag inside the applicator. Based on the inverse square law, the effective source sag was evaluated to be about 0.5 mm from the planned position. The additional dose during source transit was evaluated to be about 2.8% for 30 seconds of treatment with a 40700 U (10 Ci) source. With a very short source-to-surface distance, the small source sag inside the applicator has a significant dosimetric impact. This effect is unaccounted for in the vendor's treatment planning template and should be considered before the clinical use of the applicator. Further investigation of other applicators with large source lumen diameter may be warranted. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  16. Second salvage high-dose-rate brachytherapy for radiorecurrent prostate cancer

    NARCIS (Netherlands)

    Maenhout, Metha; Van Vulpen, Marco; Moerland, Marinus; Peters, Max; Meijer, Richard; Van Den Bosch, Maurice; Nguyen, Paul; Frank, Steven; Van Der Voort Van Zyp, Jochem

    2017-01-01

    Purpose: Salvage treatments for localized radiorecurrent prostate cancer can be performed safely when a focal and image guided approach is used. Due to the low toxicity, the opportunity exists to investigate a second salvage treatment when a second locally recurrent prostate cancer occurs. Here, we

  17. Learning curve of MRI-based planning for high-dose-rate brachytherapy for prostate cancer

    DEFF Research Database (Denmark)

    Buus, Simon; Rylander, Susanne; Hokland, Steffen

    2016-01-01

    and increased significantly from average 8.3 to 9.0 Gy (p 95% of procedures, respectively, and did not change significantly. Hematuria occurred in (95%), hematoma (80%), moderate to strong pain (35%), and urinary retention (5...

  18. Development of a program for calculation of second dose and securities in brachytherapy high dose rate

    International Nuclear Information System (INIS)

    Esteve Sanchez, S.; Martinez Albaladejo, M.; Garcia Fuentes, J. D.; Bejar Navarro, M. J.; Capuz Suarez, B.; Moris de Pablos, R.; Colmenares Fernandez, R.

    2015-01-01

    We assessed the reliability of the program with 80 patients in the usual points of prescription of each pathology. The average error of the calculation points is less than 0.3% in 95% of cases, finding the major differences in the axes of the applicators (maximum error -0.798%). The program has proved effective previously testing him with erroneous dosimetry. Thanks to the implementation of this program is achieved by the calculation of the dose and part of the process of quality assurance program in a few minutes, highlighting the case of HDR prostate due to having a limited time. Having separate data sheet allows each institution to its protocols modify parameters. (Author)

  19. Validity of the formalism of calculation in surface TG-43 brachytherapy high dose rate

    International Nuclear Information System (INIS)

    Granero, D.; Perez-Calatayud, J.; Vijande, J.; Ballester, F.; Rivard, M. J.

    2013-01-01

    The purpose of this work is to evaluate the clinical implications and limitations in implant surface with a source of HDR very close or in contact with the surface of the skin, also studied the effect of bolus on the implant. The two available radionuclides have been studied commercially in HDR, Ir-192 and Co-60 units. (Author)

  20. High-Dose-Rate Brachytherapy for the Treatment of Recalcitrant Keloids: A Unique, Effective Treatment Protocol

    NARCIS (Netherlands)

    van Leeuwen, M.C.E.; Stokmans, S.C.; Bulstra, A.E.J.; Meijer, O.W.M.; van Leeuwen, P.A.M.; Niessen, F.B.

    2014-01-01

    BACKGROUND:: Keloids cause aesthetic disfigurement and physical complaints, mainly pain and pruritus. Treatment of these scars is difficult, with high recurrence rates forming the main issue. Surgical excision with adjuvant radiotherapy is considered the most efficacious treatment. At their

  1. Application of RADPOS in Vivo Dosimetry for QA of High Dose Rate Brachytherapy

    DEFF Research Database (Denmark)

    Cherpak, A.; Kertzscher Schwencke, Gustavo Adolfo Vladimir; Cygler, J.

    2012-01-01

    Purpose: The RADPOS in vivo dosimetry system combines an electromagnetic positioning sensor with MOSFET dosimetry, allowing for simultaneous online measurements of dose and spatial position. In this work, we assess the potential use of RADPOS for measurements of motion and dose during prostate HDR...

  2. Monte Carlo study of radiation dose enhancement by gadolinium in megavoltage and high dose rate radiotherapy.

    Directory of Open Access Journals (Sweden)

    Daniel G Zhang

    Full Text Available MRI is often used in tumor localization for radiotherapy treatment planning, with gadolinium (Gd-containing materials often introduced as a contrast agent. Motexafin gadolinium is a novel radiosensitizer currently being studied in clinical trials. The nanoparticle technologies can target tumors with high concentration of high-Z materials. This Monte Carlo study is the first detailed quantitative investigation of high-Z material Gd-induced dose enhancement in megavoltage external beam photon therapy. BEAMnrc, a radiotherapy Monte Carlo simulation package, was used to calculate dose enhancement as a function of Gd concentration. Published phase space files for the TrueBeam flattening filter free (FFF and conventional flattened 6MV photon beams were used. High dose rate (HDR brachytherapy with Ir-192 source was also investigated as a reference. The energy spectra difference caused a dose enhancement difference between the two beams. Since the Ir-192 photons have lower energy yet, the photoelectric effect in the presence of Gd leads to even higher dose enhancement in HDR. At depth of 1.8 cm, the percent mean dose enhancement for the FFF beam was 0.38±0.12, 1.39±0.21, 2.51±0.34, 3.59±0.26, and 4.59±0.34 for Gd concentrations of 1, 5, 10, 15, and 20 mg/mL, respectively. The corresponding values for the flattened beam were 0.09±0.14, 0.50±0.28, 1.19±0.29, 1.68±0.39, and 2.34±0.24. For Ir-192 with direct contact, the enhanced were 0.50±0.14, 2.79±0.17, 5.49±0.12, 8.19±0.14, and 10.80±0.13. Gd-containing materials used in MRI as contrast agents can also potentially serve as radiosensitizers in radiotherapy. This study demonstrates that Gd can be used to enhance radiation dose in target volumes not only in HDR brachytherapy, but also in 6 MV FFF external beam radiotherapy, but higher than the currently used clinical concentration (>5 mg/mL would be needed.

  3. The effect of catheter displacement and anatomical variations on the dose distribution in MRI-guided focal HDR brachytherapy for prostate cancer

    NARCIS (Netherlands)

    Maenhout, Metha; van der Voort van Zyp, Jochem R N; Borot, Maxence; Peters, Max; van Vulpen, Marco; van den Bosch, Maurice; Moerland, Rien

    PURPOSE: The aim of this study was to analyze the effect of catheter displacement and anatomical variations of prostate and organs at risk on dose distribution in MRI-guided 19 Gy single fraction focal high-dose-rate brachytherapy (HDR-BT) of the prostate. METHODS AND MATERIALS: Seventeen patients

  4. Avaliação da resposta bioquímica no câncer inicial de próstata: experiência uninstitucional comparando teleterapia exclusiva ou associada à braquiterapia de alta taxa de dose Evaluation of biochemical response on early prostate cancer: comparison between treatment with external beam radiation alone and in combination with high-dose rate conformal brachytherapy boost

    Directory of Open Access Journals (Sweden)

    Douglas Guedes de Castro

    2004-08-01

    biochemical response in patients with locally advanced prostate cancer treated with external beam radiation therapy alone or in combination with conformal brachytherapy boost. MATERIALS AND METHODS: From November 1997 to January 2000, 74 patients received 45 Gy of pelvic external irradiation and four were treated with high dose rate iridium-192 conformal boost implants of 4 Gy each (BT. These were compared with 29 other patients treated with 45 Gy of pelvic external irradiation followed by a 24 Gy of bilateral ARC boost (RT from October 1996 to February 2000. Some patients received neoadjuvant androgen deprivation therapy. Three-year actuarial biochemical control rates (BC3 and pretreatment biochemical response predictors such as prostate-specific antigen pretreatment (PSAi, Gleason score (GS and clinical stage (CS, were evaluated. RESULTS: Median follow-up was of 25 months for the RT group and 37 months for the BT group. BC3 was 51% versus 73% (p = 0.032 for RT and BT, respectively. Comparisons of biochemical control by treatment group stratified by PSAi showed that BC3 for RT versus BT was 85.7% versus 79.1% (p = 0.76 for PSAi 10 ng/mL, respectively. For patients with GS 6, BC3 was 78% versus 55% (p = 0.58 for RT versus BT, respectively. For patients with CS T2a, BC3 was 73% versus 69% (p = 0.692 for RT versus BT, respectively. The relative risk of biochemical relapse was 2.3 (95% IC: 1.0-5.1 for patients in RT group compared to the BT group. When adjusted for PSAi and GS, the relative risk of biochemical relapse was 2.4 (95% IC: 1.0-5.7. CONCLUSION: The treatment modality was an independent prognostic factor for biochemical relapse, with a significant improvement in the biochemical control with BT. These early results suggest that this treatment was most beneficial in patients with PSAi > 10 ng/mL, CS < T2a and GS < 6.

  5. Implementing MRI-based target delineation for cervical cancer treatment within a rapid workflow environment for image-guided brachytherapy: A practical approach for centers without in-room MRI.

    Science.gov (United States)

    Trifiletti, Daniel M; Libby, Bruce; Feuerlein, Sebastian; Kim, Taeho; Garda, Allison; Watkins, W Tyler; Erickson, Sarah; Ornan, Afshan; Showalter, Timothy N

    2015-01-01

    Magnetic resonance imaging (MRI)-based intracavitary brachytherapy offers several advantages over computed tomography (CT)-based brachytherapy, but many centers are unable to offer it at the time of brachytherapy because of logistic and/or financial considerations. We have implemented a method of integrating MRI into a CT-guided, high-dose-rate intracavitary brachytherapy workflow in clinics that do not have immediately available MRI capability. At our institution, patients receiving high-dose-rate intracavitary brachytherapy as a component of the definitive treatment of cervical cancer have a Smit sleeve placed during the first brachytherapy fraction in a dedicated suite with in-room CT-on-rails. After the first fraction of brachytherapy, an MRI is obtained with the Smit sleeve, but no applicator, in place. For each subsequent fraction, CT scans are coregistered to the MRI scan by the Smit sleeve. The gross target volume is defined by MRI and overlaid on the CT images for each brachytherapy treatment for dose optimization. This MRI-integrated workflow adds workflow is a feasible compromise to preserve an efficient workflow while integrating MRI target delineation, and it provides many of the advantages of both MRI- and CT-based brachytherapy. The future collection and analysis of clinical data will serve to compare the proposed approach to non-MRI containing techniques. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  6. Work in progress: californium-252 brachytherapy plus fractionated irradiation for advanced tonsillar carcinoma.

    Science.gov (United States)

    Maruyama, Y

    1983-07-01

    A feasibility trial of californium-252 neutron brachytherapy combined with fractionated cobalt-60 therapy for advanced but localized stage T4 tonsillar-retromolar carcinoma is described. Seven patients with primary tumors who were not suitable for conventional radical surgery, chemoradiotherapy and surgery, or surgery plus irradiation were treated. There was complete tumor response in all cases.

  7. Survival of tumor cells after proton irradiation with ultra-high dose rates

    International Nuclear Information System (INIS)

    Auer, Susanne; Hable, Volker; Greubel, Christoph; Drexler, Guido A; Schmid, Thomas E; Belka, Claus; Dollinger, Günther; Friedl, Anna A

    2011-01-01

    Laser acceleration of protons and heavy ions may in the future be used in radiation therapy. Laser-driven particle beams are pulsed and ultra high dose rates of >10 9 Gy s -1 may be achieved. Here we compare the radiobiological effects of pulsed and continuous proton beams. The ion microbeam SNAKE at the Munich tandem accelerator was used to directly compare a pulsed and a continuous 20 MeV proton beam, which delivered a dose of 3 Gy to a HeLa cell monolayer within < 1 ns or 100 ms, respectively. Investigated endpoints were G2 phase cell cycle arrest, apoptosis, and colony formation. At 10 h after pulsed irradiation, the fraction of G2 cells was significantly lower than after irradiation with the continuous beam, while all other endpoints including colony formation were not significantly different. We determined the relative biological effectiveness (RBE) for pulsed and continuous proton beams relative to x-irradiation as 0.91 ± 0.26 and 0.86 ± 0.33 (mean and SD), respectively. At the dose rates investigated here, which are expected to correspond to those in radiation therapy using laser-driven particles, the RBE of the pulsed and the (conventional) continuous irradiation mode do not differ significantly

  8. Long duration mild temperature hyperthermia and brachytherapy.

    Science.gov (United States)

    Armour, E P; Raaphorst, G P

    2004-03-01

    Combining long duration mild temperature hyperthermia (LDMH) and low dose-rate (LDR) brachytherapy to enhance therapeutic killing of cancer cells was proposed many years ago. The cellular and tumour research that supports this hypothesis is presented in this review. Research describing LDMH interaction with pulsed brachytherapy and high dose-rate brachytherapy using clinically relevant parameters are compared with LDMH/LDR brachytherapy. The mechanism by which LDMH sensitizes LDR has been established as the inhibition of sublethal damage repair. The molecular mechanisms have been shown to involve DNA repair enzymes, but the exact nature of these processes is still under investigation. The relative differences between LDMH interactions with human and rodent cells are presented to help in the understanding of possible roles of LDMH in clinical application. The role of LDMH in modifying tumour blood flow and its possible role in LDR sensitization of tumours is also presented. The positive aspects of LDMH-brachytherapy for clinical application are sixfold; (1) the thermal goals (temperature, time and volume) are achievable with currently available technology, (2) the hyperthermia by itself has no detectable toxic effects, (3) thermotolerance appears to play a minor if any role in radiation sensitization, (4) TER of around 2 can be expected, (5) hypoxic fraction may be decreased due to blood flow modification and (6) simultaneous chemotherapy may also be sensitized. Combined LDMH and brachytherapy is a cancer therapy that has established biological rationale and sufficient technical and clinical advancements to be appropriately applied. This modality is ripe for clinical testing.

  9. Clastogenic effects in human lymphocytes exposed to low and high dose rate X-ray irradiation and vitamin C

    International Nuclear Information System (INIS)

    Konopacka, M; Rogolinski, J.

    2011-01-01

    In the present work we investigated the ability of vitamin C to modulate clastogenic effects induced in cultured human lymphocytes by X-irradiation delivered at either high (1 Gy/min) or low dose rate (0.24 Gy/min). Biological effects of the irradiation were estimated by cytokinesis-block micronucleus assay including the analysis of the frequency of micronuclei (MN) and apoptotic cells as well as calculation of nuclear division index (NDI). The numbers of micronucleated binucleate lymphocytes (MN-CBL) were 24.85 ± 2.67% and 32.56 ± 3.17% in cultures exposed to X-rays (2 Gy) delivered at low and high dose rates, respectively. Addition of vitamin C (1-20 μg/ml) to the medium of cultures irradiated with the low dose rate reduced the frequency of micronucleated lymphocytes with multiple MN in a concentration-dependent manner. Lymphocytes exposed to the high dose rate radiation showed a U-shape response: low concentration of vitamin C significantly reduced the number of MN, whereas high concentration influenced the radiation-induced total number of micronucleated cells insignificantly, although it increased the number of cells with multiple MN. Addition of vitamin C significantly reduced the fraction of apoptotic cells, irrespective of the X-ray dose rate. These results indicate that radiation dose rate is an important exposure factor, not only in terms of biological cell response to irradiation, but also with respect to the modulating effects of antioxidants. (authors)

  10. Dose Escalation Improves Cancer-Related Events at 10 Years for Intermediate- and High-Risk Prostate Cancer Patients Treated With Hypofractionated High-Dose-Rate Boost and External Beam Radiotherapy

    International Nuclear Information System (INIS)

    Martinez, Alvaro A.; Gonzalez, Jose; Ye Hong; Ghilezan, Mihai; Shetty, Sugandh; Kernen, Kenneth; Gustafson, Gary; Krauss, Daniel; Vicini, Frank; Kestin, Larry

    2011-01-01

    Purpose: To evaluate the 10-year outcomes of intermediate- and high-risk prostate cancer patients treated with a prospective dose escalation hypofractionated trial of pelvic external beam radiation therapy (P-EBRT) with a high-dose-rate (HDR) brachytherapy boost. Methods and Materials: From 1992 to 2007, 472 patients were treated with a HDR boost at William Beaumont Hospital. They had at least one of the following: a prostate-specific antigen (PSA) level of >10 ng/ml, a Gleason score of ≥7, or clinical stage ≥T2b. Patients received 46-Gy P-EBRT and an HDR boost. The HDR dose fractionation was divided into two dose levels. The prostate biologically equivalent dose (BED) low-dose-level group received 268 Gy . Phoenix biochemical failure (BF) definition was used. Results: Median follow-up was 8.2 years (range, 0.4-17 years). The 10-year biochemical failure rate of 43.1% vs. 18.9%, (p 268Gy) has significantly decreased biochemical and clinical failures as well as distant metastasis.

  11. Vaginal brachytherapy alone is sufficient adjuvant treatment of surgical stage I endometrial cancer

    International Nuclear Information System (INIS)

    Solhjem, Matthew C.; Petersen, Ivy A.; Haddock, Michael G.

    2005-01-01

    Purpose To determine the efficacy and complications of adjuvant vaginal high-dose-rate brachytherapy alone for patients with Stage I endometrial cancer in whom complete surgical staging had been performed. Methods and Materials Between April 1998 and March 2004, 100 patients with Stage I endometrial cancer underwent surgical staging (total abdominal hysterectomy and bilateral salpingo-oophorectomy with pelvic ± paraaortic nodal sampling) and postoperative vaginal high-dose-rate brachytherapy at our institution. The total dose was 2100 cGy in three fractions. Results With a median follow-up of 23 months (range 2-62), no pelvic or vaginal recurrences developed. All patients underwent pelvic dissection, and 42% underwent paraaortic nodal dissection. A median of 29.5 pelvic nodes (range 1-67) was removed (84% had >10 pelvic nodes removed). Most patients (73%) had endometrioid (or unspecified) adenocarcinoma, 16% had papillary serous carcinoma, and 11% had other histologic types. The International Federation of Gynecology and Obstetrics stage and grade was Stage IA, grade III in 5; Stage IB, grade I, II, or III in 6, 27, or 20, respectively; and Stage IC, grade I, II, or III in 13, 17, or 10, respectively. The Common Toxicity Criteria (version 2.0) complications were mild (Grade 1-2) and consisted primarily of vaginal mucosal changes, temporary urinary irritation, and temporary diarrhea. Conclusion Adjuvant vaginal high-dose-rate brachytherapy alone may be a safe and effective alternative to pelvic external beam radiotherapy for surgical Stage I endometrial cancer

  12. Fractionation in medium dose rate brachytherapy of cancer of the cervix

    International Nuclear Information System (INIS)

    Leborgne, Felix; Fowler, Jack F.; Leborgne, Jose H.; Zubizarreta, Eduardo; Chappell, Rick

    1996-01-01

    Purpose: To establish an optimum fractionation for medium dose rate (MDR) brachytherapy from retrospective data of patients treated with different MDR schedules in comparison with a low dose rate (LDR) schedule. Methods and Materials: The study population consists of consecutive Stage IB-IIA-IIB patients who received radiotherapy alone with full dose brachytherapy plus external beam pelvic and parametrial irradiation from 1986-1993. Patients also receiving surgery or chemotherapy were excluded. The LDR group (n = 102, median follow-up: 80 months) received a median dose to Point A of two 32.5 Gy fractions at 0.44 Gy/h plus 18 Gy of external whole pelvic irradiation. The MDR1 group (n = 30, median follow-up: 45 months) received a mean dose of two 32 Gy fractions at 1.68 Gy/h. An individual dose reduction of 12.5% was planned for this group according to the Manchester experience, but only a 4.8% dose reduction was achieved. The MDR2 group (n = 10, median follow-up: 36 months) received a dose of two 24 Gy fractions at 1.65 Gy/h. The MDR3 group (n = 10, median follow-up 33 months) received a mean dose of three 15.3 Gy fractions at 1.64 Gy/h. And finally, the MDR4 group (n = 38, median follow-up: 24 months) received six 7.7 Gy fractions from two pulses 6 h apart in each of three insertions at 1.61 Gy/h. The median external pelvic dose to MDR schedules was between 12 and 20 Gy. The linear quadratic (LQ) formula was used to calculate the biologically effective dose (BED) to tumor (Gy 10 ) and rectum (Gy 3 ), assuming T(1(2)) for repair = 1.5 h. Results: The crude central recurrence rate was 6% for LDR (mean BED = 95.4 Gy 10 ) and 10% for MDR4 (mean BED = 77.0 Gy 10 ) (p = NS). The remaining MDR groups had no recurrences. Grade 2 and 3 rectal or bladder complications were 0% for LDR (rectal BED = 109 Gy 3 ), 83% for MDR1 (BED = 206 Gy 3 ), and 30% for MDR3 (BED = 127 Gy 3 ). The MDR2 and MDR4 groups presented no complications (BED, 123 Gy 3 , and 105 Gy 3 , respectively

  13. A review of the clinical experience in pulsed dose rate brachytherapy

    NARCIS (Netherlands)

    Balgobind, Brian V.; Koedooder, Kees; Ordoñez Zúñiga, Diego; Dávila Fajardo, Raquel; Rasch, Coen R. N.; Pieters, Bradley R.

    2015-01-01

    Pulsed dose rate (PDR) brachytherapy is a treatment modality that combines physical advantages of high dose rate (HDR) brachytherapy with the radiobiological advantages of low dose rate brachytherapy. The aim of this review was to describe the effective clinical use of PDR brachytherapy worldwide in

  14. Pre-installation empirical testing of room shielding for high dose rate remote afterloaders

    International Nuclear Information System (INIS)

    Klein, E.E.; Grigsby, P.W.; Williamson, J.F.; Meigooni, A.S.

    1993-01-01

    PURPOSE: Many facilities are acquiring high dose rate remote afterloading units. It is economical that these units be placed in existing shielded teletherapy rooms. Scatter-radiation barriers marginally protect uncontrolled areas from a high dose rate source especially in a room that houses a non-dynamic Cobalt-60 unit. In addition the exact thickness and material composition of the barriers are unknown and therefore, a calculation technique may give misleading results. Also, it would be impossible to evaluate an entire wall barrier by taking isolated core samples in order to assist in the calculations. A quick and inexpensive measurement of dose equivalent using a rented high activity 192Ir source evaluates the barriers and locates shielding deficiencies. METHODS AND MATERIALS: We performed transmission calculations for primary and scattered radiation based on National Council on Radiation Protection and Measurements Reports 49 and 51, respectively. We then rented a high activity 21.7 Ci (8.03 x 10(11) Bq) Ir-192 source to assess our existing teletherapy room shielding for adequacy and voids. This source was placed at the proposed location for clinical high dose rate treatment and measurements were performed. RESULTS: No deficiencies were found in controlled areas surrounding the room, but large differences were found between the calculated and measured values. Our survey located a region in the uncontrolled area above the room requiring augmented shielding which was not predicted by the calculations. A canopy shield was designed to potentially augment the shielding in the ceiling direction. CONCLUSION: Pre-installation testing by measurement is an invaluable method for locating shielding deficiencies and avoiding unnecessary enhancement of shielding particularly when there is lack of information of the inherent shielding

  15. Collection of radiation resistant characteristics reports for instruments and materials in high dose rate environment

    International Nuclear Information System (INIS)

    Kusano, Joichi

    2008-03-01

    This document presents the collected official reports of radiation irradiation study for the candidate materials to be used in high dose rate environment as J-PARC facility. The effect of radiation damage by loss-beam or secondary particle beam of the accelerators influences the performance and the reliability of various instruments. The knowledge on the radiation resistivity of the materials is important to estimate the life of the equipments, the maintenance interval and dose evaluation for the personnel at the maintenance period. The radiation damage consists with mechanical property, electrical property and gas-evolution property. (author)

  16. Total skin high-dose-rate electron therapy dosimetry using TG-51

    International Nuclear Information System (INIS)

    Gossman, Michael S.; Sharma, Subhash C.

    2004-01-01

    An approach to dosimetry for total skin electron therapy (TSET) is discussed using the currently accepted TG-51 high-energy calibration protocol. The methodology incorporates water phantom data for absolute calibration and plastic phantom data for efficient reference dosimetry. The scheme is simplified to include the high-dose-rate mode conversion and provides support for its use, as it becomes more available on newer linear accelerators. Using a 6-field, modified Stanford technique, one may follow the process for accurate determination of absorbed dose

  17. A method for checking high dose rate treatment times for vaginal applicators.

    Science.gov (United States)

    Mayo, C S; Ulin, K

    2001-01-01

    A method is presented for checking the treatment time calculation for high dose rate (HDR) vaginal cylinder treatments. The method represents an independent check of the HDR planning system and can take into account nonuniform isodose line coverage around the cylinder. Only the air kerma strength of the source and information that is available from the written directive are required. The maximum discrepancy for a representative set of cylinder plans done on a Nucletron unit was 5%. A working HTML JavaScript program is included in the Appendix.

  18. On-Line High Dose-rate Gamma Irradiation Test of the Profibus/DP module

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Choi, Young Soo; Kim, Chang Hoi; Koo, In Soo; Hong, Seok Boong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The field bus data communication is considered for application in nuclear environments. The nuclear facilities, including nuclear power plants, high radioactivity waste disposals, reprocessing plants and thermonuclear fusion installations can benefit from the unique advantages of the field bus communication network for the smart field instruments and controls. A major problem which arises when dealing with one in these nuclear environments, in special circumstances such as the RCS (reactor coolant system) area, is the presence of high gamma-ray irradiation fields. Radioactive constraints for the DBA(design basis accident) qualification of the RTD transmitter installed in the inside of the RCS pump are typically on the order of 4kGy/h with total doses up to 10kGy. In order to use an industrial field bus communication network as an ad-hoc sensor data link in the vicinity of the RCS area of the nuclear power plant, the robust survivability of these system in such intense gamma-radiation fields therefore needs to be verified. We have conducted high dose-rate (up to 4kGy) gamma irradiation experiments on a profibus/DP communication module. In this paper we describe the evolution of its basic characteristics with high dose-rate gamma irradiation and shortly explain the observed phenomena.

  19. On-Line High Dose-rate Gamma Irradiation Test of the Profibus/DP module

    International Nuclear Information System (INIS)

    Cho, Jai Wan; Choi, Young Soo; Kim, Chang Hoi; Koo, In Soo; Hong, Seok Boong

    2009-01-01

    The field bus data communication is considered for application in nuclear environments. The nuclear facilities, including nuclear power plants, high radioactivity waste disposals, reprocessing plants and thermonuclear fusion installations can benefit from the unique advantages of the field bus communication network for the smart field instruments and controls. A major problem which arises when dealing with one in these nuclear environments, in special circumstances such as the RCS (reactor coolant system) area, is the presence of high gamma-ray irradiation fields. Radioactive constraints for the DBA(design basis accident) qualification of the RTD transmitter installed in the inside of the RCS pump are typically on the order of 4kGy/h with total doses up to 10kGy. In order to use an industrial field bus communication network as an ad-hoc sensor data link in the vicinity of the RCS area of the nuclear power plant, the robust survivability of these system in such intense gamma-radiation fields therefore needs to be verified. We have conducted high dose-rate (up to 4kGy) gamma irradiation experiments on a profibus/DP communication module. In this paper we describe the evolution of its basic characteristics with high dose-rate gamma irradiation and shortly explain the observed phenomena

  20. Effects of high dose rate gamma radiation on survival and reproduction of Biomphalaria glabrata

    Energy Technology Data Exchange (ETDEWEB)

    Cantinha, Rebeca S.; Nakano, Eliana [Instituto Butantan, Sao Paulo, SP (Brazil). Lab. de Parasitologia], e-mail: rebecanuclear@gmail.com, e-mail: eliananakano@butantan.gov.br; Borrely, Sueli I. [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Centro de Tecnologia das Radiacoes], e-mail: sborrely@ipen.br; Amaral, Ademir; Melo, Ana M.M.A. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear. Grupo de Estudos em Radioprotecao e Radioecologia (GERAR)], e-mail: amaral@ufpe.br; Silva, Luanna R.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Biofisica e Radiobiologia. Lab. de Radiobiologia], e-mail: amdemelo@hotmail.com, e-mail: luannaribeiro_lua@hotmail.com

    2009-07-01

    Ionizing radiations are known as mutagenic agents, causing lethality and infertility. This characteristic has motivated its application on animal biological control. In this context, the freshwater snail Biomphalaria glabrata can be considered an excellent experimental model to study effects of ionizing radiations on lethality and reproduction. This work was designed to evaluate effects of {sup 60}Co gamma radiation at high dose rate (10.04 kGy/h) on B. glabrata. For this purpose, adult snails were selected and exposed to doses ranging from 20 to 100 Gy, with 10 Gy intervals; one group was kept as control. There was not effect of dose rate in the lethality of gamma radiation; the value of 64,3 Gy of LD{sub 50} obtained in our study was similar to that obtained by other authors with low dose rates. Nevertheless, our data suggest that there was a dose rate effect in the reproduction. On all dose levels, radiation improved the production of embryos for all exposed individuals. However, viability indexes were below 6% and, even 65 days after irradiation, fertility was not recovered. These results are not in agreement with other studies using low dose rates. Lethality was obtained in all groups irradiated, and the highest doses presented percentiles of dead animals above 50%. The results demonstrated that doses of 20 and 30 Gy were ideal for population control of B. glabrata. Further studies are needed; nevertheless, this research evidenced great potential of high dose rate gamma radiation on B. glabrata reproductive control. (author)