WorldWideScience

Sample records for fractional intensity diameters

  1. The design of cermet fuel phase fraction and fuel particle diameter

    International Nuclear Information System (INIS)

    Tian Sheng.

    1986-01-01

    UO 2 -Zr-2 is an ideal cermet fuel. As an exemplification with this fuel, this paper emphatically elucidates the irradiation theory of cermet fuel and its application in the design of cermet fuel phase fraction and of fuel particle diameter. From the point of view of the irradiation theory and the consideration for sandwich rolling, the suitable volume fraction of UO 2 phase of 25% and diameter of UO 2 particle of 100 +- 15 μm are selected

  2. High-Intensity Interval Training in Patients with Heart Failure with Reduced Ejection Fraction

    DEFF Research Database (Denmark)

    Ellingsen, Øyvind; Halle, Martin; Conraads, Viviane

    2017-01-01

    Background: Small studies have suggested that high-intensity interval training (HIIT) is superior to moderate continuous training (MCT) in reversing cardiac remodeling and increasing aerobic capacity in patients with heart failure with reduced ejection fraction. The present multicenter trial...... compared 12 weeks of supervised interventions of HIIT, MCT, or a recommendation of regular exercise (RRE). Methods: Two hundred sixty-one patients with left ventricular ejection fraction ≤35% and New York Heart Association class II to III were randomly assigned to HIIT at 90% to 95% of maximal heart rate...... ventricular end-diastolic diameter from baseline to 12 weeks. Results: Groups did not differ in age (median, 60 years), sex (19% women), ischemic pathogenesis (59%), or medication. Change in left ventricular end-diastolic diameter from baseline to 12 weeks was not different between HIIT and MCT (P=0.45); left...

  3. Influence of high intensity ultrasound with different probe diameter ...

    African Journals Online (AJOL)

    The main goal of this research is to analyze the influence of ultrasonic probe diameters (7 and 10 mm) of high-intensity ultrasound with constant frequency (30 kHz) on the degree of homogenization (variance) of cow milk. Influence of different probe diameters on the physical properties of cow milk was also tested. Changes ...

  4. The influence of upper airways diameter on the intensity of obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    Jolanta Szymańska

    2014-03-01

    Full Text Available Introduction and Objective. Obstructive sleep apnea (OSA is characterized by at least 5 ten-second-long episodes of apnea or hypopnea, per hour of sleep. This disease may lead to severe, life-threatening complications. Therefore, risk analysis and its influence on disease intensity is crucial for proper implementation of preventive treatments. Objective. To determine the relation between the intensity of OSA expressed in Apnea-Hypopnea Index (AHI, and the anterior-posterior diameter of upper airways at the levels of soft palate and tongue base. Material and Method. Medical records of 41 patients with sleep apnea (AHI>4 diagnosed through polysomnographic examination obstructive were used for the study. The data consisted of: age and gender, polysomnographic examination results (AHI, lateral cephalogram with cephalomertic analysis, together with measurements of the upper and lower pharyngeal depth according to McNamara. Statistical analysis was carried out in accordance with Pearson’s r correlation coefficient test (Statistica 8.0 software package. Results. Analysis of the influence of upper airways diameter on the intensity of OSA showed that the value of upper Airways diameter at the tongue base level had no statistically significant impact on the value of AHI (p=0.795. However, a statistically significant impact of the value of upper airways diameter on the AHI value (p=0.008 at the soft palate level was observed. Patients with OSA have narrowed upper airways diameter. The value of AHI increases with the decrease of upper diameter and is not dependent on a lower diameter value. Patients with a decreased upper airways diameter should be informed about potential breathing disorders during sleep.

  5. High-Intensity Interval Training in Patients With Heart Failure With Reduced Ejection Fraction.

    Science.gov (United States)

    Ellingsen, Øyvind; Halle, Martin; Conraads, Viviane; Støylen, Asbjørn; Dalen, Håvard; Delagardelle, Charles; Larsen, Alf-Inge; Hole, Torstein; Mezzani, Alessandro; Van Craenenbroeck, Emeline M; Videm, Vibeke; Beckers, Paul; Christle, Jeffrey W; Winzer, Ephraim; Mangner, Norman; Woitek, Felix; Höllriegel, Robert; Pressler, Axel; Monk-Hansen, Tea; Snoer, Martin; Feiereisen, Patrick; Valborgland, Torstein; Kjekshus, John; Hambrecht, Rainer; Gielen, Stephan; Karlsen, Trine; Prescott, Eva; Linke, Axel

    2017-02-28

    Small studies have suggested that high-intensity interval training (HIIT) is superior to moderate continuous training (MCT) in reversing cardiac remodeling and increasing aerobic capacity in patients with heart failure with reduced ejection fraction. The present multicenter trial compared 12 weeks of supervised interventions of HIIT, MCT, or a recommendation of regular exercise (RRE). Two hundred sixty-one patients with left ventricular ejection fraction ≤35% and New York Heart Association class II to III were randomly assigned to HIIT at 90% to 95% of maximal heart rate, MCT at 60% to 70% of maximal heart rate, or RRE. Thereafter, patients were encouraged to continue exercising on their own. Clinical assessments were performed at baseline, after the intervention, and at follow-up after 52 weeks. Primary end point was a between-group comparison of change in left ventricular end-diastolic diameter from baseline to 12 weeks. Groups did not differ in age (median, 60 years), sex (19% women), ischemic pathogenesis (59%), or medication. Change in left ventricular end-diastolic diameter from baseline to 12 weeks was not different between HIIT and MCT ( P =0.45); left ventricular end-diastolic diameter changes compared with RRE were -2.8 mm (-5.2 to -0.4 mm; P =0.02) in HIIT and -1.2 mm (-3.6 to 1.2 mm; P =0.34) in MCT. There was also no difference between HIIT and MCT in peak oxygen uptake ( P =0.70), but both were superior to RRE. However, none of these changes was maintained at follow-up after 52 weeks. Serious adverse events were not statistically different during supervised intervention or at follow-up at 52 weeks (HIIT, 39%; MCT, 25%; RRE, 34%; P =0.16). Training records showed that 51% of patients exercised below prescribed target during supervised HIIT and 80% above target in MCT. HIIT was not superior to MCT in changing left ventricular remodeling or aerobic capacity, and its feasibility remains unresolved in patients with heart failure. URL: http

  6. Dryout-type critical heat flux in vertical upward annular flow: effects of entrainment rate, initial entrained fraction and diameter

    Science.gov (United States)

    Wu, Zan; Wadekar, Vishwas; Wang, Chenglong; Sunden, Bengt

    2018-01-01

    This study aims to reveal the effects of liquid entrainment, initial entrained fraction and tube diameter on liquid film dryout in vertical upward annular flow for flow boiling. Entrainment and deposition rates of droplets were included in mass conservation equations to estimate the local liquid film mass flux in annular flow, and the critical vapor quality at dryout conditions. Different entrainment rate correlations were evaluated using flow boiling data of water and organic liquids including n-pentane, iso-octane and R134a. Effect of the initial entrained fraction (IEF) at the churn-to-annular flow transition was also investigated. A transitional Boiling number was proposed to separate the IEF-sensitive region at high Boiling numbers and the IEF-insensitive region at low Boiling numbers. Besides, the diameter effect on dryout vapor quality was studied. The dryout vapor quality increases with decreasing tube diameter. It needs to be pointed out that the dryout characteristics of submillimeter channels might be different because of different mechanisms of dryout, i.e., drying of liquid film underneath long vapor slugs and flow boiling instabilities.

  7. Void fraction development in gas-liquid flow after a U-bend in a vertically upwards serpentine-configuration large-diameter pipe

    Science.gov (United States)

    Almabrok, Almabrok A.; Aliyu, Aliyu M.; Baba, Yahaya D.; Lao, Liyun; Yeung, Hoi

    2018-01-01

    We investigate the effect of a return U-bend on flow behaviour in the vertical upward section of a large-diameter pipe. A wire mesh sensor was employed to study the void fraction distributions at axial distances of 5, 28 and 47 pipe diameters after the upstream bottom bend. The study found that, the bottom bend has considerable impacts on up-flow behaviour. In all conditions, centrifugal action causes appreciable misdistribution in the adjacent straight section. Plots from WMS measurements show that flow asymmetry significantly reduces along the axis at L/D = 47. Regime maps generated from three axial locations showed that, in addition to bubbly, intermittent and annular flows, oscillatory flow occurred particularly when gas and liquid flow rates were relatively low. At this position, mean void fractions were in agreement with those from other large-pipe studies, and comparisons were made with existing void fraction correlations. Among the correlations surveyed, drift flux-type correlations were found to give the best predictive results.

  8. Hyperdynamic left ventricular ejection fraction in the intensive care unit.

    Science.gov (United States)

    Paonessa, Joseph R; Brennan, Thomas; Pimentel, Marco; Steinhaus, Daniel; Feng, Mengling; Celi, Leo Anthony

    2015-08-07

    Limited information exists on the etiology, prevalence, and significance of hyperdynamic left ventricular ejection fraction (HDLVEF) in the intensive care unit (ICU). Our aim in the present study was to compare characteristics and outcomes of patients with HDLVEF with those of patients with normal left ventricular ejection fraction in the ICU using a large, public, deidentified critical care database. We conducted a longitudinal, single-center, retrospective cohort study of adult patients who underwent echocardiography during a medical or surgical ICU admission at the Beth Israel Deaconess Medical Center using the Multiparameter Intelligent Monitoring in Intensive Care II database. The final cohort had 2867 patients, of whom 324 had HDLVEF, defined as an ejection fraction >70%. Patients with an ejection fraction <55% were excluded. Compared with critically ill patients with normal left ventricular ejection fraction, the finding of HDLVEF in critically ill patients was associated with female sex, increased age, and the diagnoses of hypertension and cancer. Patients with HDLVEF had increased 28-day mortality compared with those with normal ejection fraction in multivariate logistic regression analysis adjusted for age, sex, Sequential Organ Failure Assessment score, Elixhauser score for comorbidities, vasopressor use, and mechanical ventilation use (odds ratio 1.38, 95% confidence interval 1.039-1.842, p =0.02). The presence of HDLVEF portended increased 28-day mortality, and may be helpful as a gravity marker for prognosis in patients admitted to the ICU. Further research is warranted to gain a better understanding of how these patients respond to common interventions in the ICU and to determine if pharmacologic modulation of HDLVEF improves outcomes.

  9. Investigation of magnetic active core sizes and hydrodynamic diameters of a magnetically fractionated ferrofluid

    International Nuclear Information System (INIS)

    Büttner, Markus; Weber, Peter; Schmidl, Frank; Seidel, Paul; Röder, Michael; Schnabelrauch, Matthias; Wagner, Kerstin; Görnert, Peter; Glöckl, Gunnar; Weitschies, Werner

    2011-01-01

    In this work we address the question which relates between the size of the magnetically active core of magnetic nanoparticles (MNPs) and the size of the overall particle in the solution (the so-called hydrodynamic diameter d hyd ) exists. For this purpose we use two methods of examination that can deliver conclusions about the properties of MNP which are not accessible with normal microscopy. On the one hand, we use temperature dependent magnetorelaxation (TMRX) method, which enables direct access to the energy barrier distribution and by using additional hysteresis loop measurements can provide details about the size of the magnetically active cores. On the other hand, to determine the size of the overall particle in the solution, we use the magnetooptical relaxation of ferrofluids (MORFF) method, where the stimulation is done magnetically while the reading of the relaxation signal, however, is done optically. As a basis for the examinations in this work we use a ferrofluid that was developed for medicinal purposes and which has been fractioned magnetically to obtain differently sized fractions of MNPs. The two values obtained through these methods for each fraction shows the success in fractioning the original solution. Therefore, one can conclude a direct correlation between the size of the magnetically active core and the size of the complete particle in the solution from the experimental results. To calculate the size of the magnetically active core we found a temperature dependent anisotropy constant which was taken into account for the calculations. Furthermore, we found relaxation signals at 18 K for all fractions in these TMRX measurements, which have their origin in other magnetic effects than the Néel relaxation.

  10. Combustion characteristics of intensively cleaned coal fractions. Effect of mineral matter

    Energy Technology Data Exchange (ETDEWEB)

    Rubiera, F.; Arenillas, A.; Fuente, E.; Pis, J.J. [Inst. Nacional de Carbon, Oviedo (Spain); Ivatt, S. [ETSU, Harwell, Didcot (United Kingdom)

    1997-12-31

    The purpose of this work has been to assess the effect that intensive coal cleaning exerts on the combustion behaviour of different density-separated coal fractions. Samples with ash contents varying from 39% for the raw coal, to 2% for the cleanest fraction were obtained after density separation. Temperature-programmed combustion and isothermal gasification in air were used to measure the reactivities of the parent coal and the cleaned fractions. Coal and char reactivities increased with increasing ash content of the samples. Thermal analysis-mass spectrometry of the low-temperature ashes was also carried out in order to study the reactions of coal minerals under combustion conditions. (orig.)

  11. Usefulness of left ventricular wall thickness-to-diameter ratio in thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Manno, B.; Hakki, A.H.; Kane, S.A.; Iskandrian, A.S.

    1983-01-01

    The ratio of left ventricular wall thickness to the cavity dimension, as seen on thallium-201 images, was used in this study to predict left ventricular ejection fraction and volume. We obtained rest thallium-201 images in 50 patients with symptomatic coronary artery disease. The thickness of a normal-appearing segment of the left ventricular wall and the transverse diameter of the cavity were measured in the left anterior oblique projection. The left ventricular ejection fraction and volume in these patients were determined by radionuclide ventriculography. There was a good correlation between thickness-to-diameter ratio and ejection fraction and end-systolic volume. In 18 patients with a thickness-to-diameter ratio less than 0.70, the ejection fraction was lower than in the 16 patients with thickness-to-diameter ratio greater than or equal to 1.0. Similarly, in patients with a thickness-to-diameter ratio less than 0.70, the end-diastolic and end-systolic volume were higher than in the remaining patients with higher thickness-to-diameter ratios. All 18 patients with a thickness-to-diameter ratio less than 0.70 had ejection fractions less than 40%; 14 of 15 patients with a thickness-to-diameter ratio greater than or equal to 1.0 had an ejection fraction greater than 40%. The remaining 16 patients with a thickness-to-diameter ratio of 0.7-0.99 had intermediate ejection fractions and volumes.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Finite-mode analysis by means of intensity information in fractional optical systems

    NARCIS (Netherlands)

    Alieva, T.; Bastiaans, M.J.

    2002-01-01

    It is shown how a coherent optical signal that contains only a finite number of Hermite-Gauss modes, can be reconstructed from the knowledge of its Radon-Wigner transform -- associated with the intensity distribution in a fractional Fourier transform optical system -- at only two transversal points.

  13. Fractionation and Characterization of High Aspect Ratio Gold Nanorods Using Asymmetric-Flow Field Flow Fractionation and Single Particle Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Thao M. Nguyen

    2015-07-01

    Full Text Available Gold nanorods (GNRs are of particular interest for biomedical applications due to their unique size-dependent longitudinal surface plasmon resonance band in the visible to near-infrared. Purified GNRs are essential for the advancement of technologies based on these materials. Used in concert, asymmetric-flow field flow fractionation (A4F and single particle inductively coupled mass spectrometry (spICP-MS provide unique advantages for fractionating and analyzing the typically complex mixtures produced by common synthetic procedures. A4F fractions collected at specific elution times were analyzed off-line by spICP-MS. The individual particle masses were obtained by conversion of the ICP-MS pulse intensity for each detected particle event, using a defined calibration procedure. Size distributions were then derived by transforming particle mass to length assuming a fixed diameter. The resulting particle lengths correlated closely with ex situ transmission electron microscopy. In contrast to our previously reported observations on the fractionation of low-aspect ratio (AR GNRs (AR < 4, under optimal A4F separation conditions the results for high-AR GNRs of fixed diameter (≈20 nm suggest normal, rather than steric, mode elution (i.e., shorter rods with lower AR generally elute first. The relatively narrow populations in late eluting fractions suggest the method can be used to collect and analyze specific length fractions; it is feasible that A4F could be appropriately modified for industrial scale purification of GNRs.

  14. Calibration of the Diameter Distribution Derived from the Area-based Approach with Individual Tree-based Diameter Estimates Using the Airborne Laser Scanning

    Science.gov (United States)

    Xu, Q.; Hou, Z.; Maltamo, M.; Tokola, T.

    2015-12-01

    Diameter distributions of trees are important indicators of current forest stand structure and future dynamics. A new method was proposed in the study to combine the diameter distributions derived from the area-based approach (ABA) and the diameter distribution derived from the individual tree detection (ITD) in order to obtain more accurate forest stand attributes. Since dominant trees can be reliably detected and measured by the Lidar data via the ITD, the focus of the study is to retrieve the suppressed trees (trees that were missed by the ITD) from the ABA. Replacement and histogram matching were respectively employed at the plot level to retrieve the suppressed trees. Cut point was detected from the ITD-derived diameter distribution for each sample plot to distinguish dominant trees from the suppressed trees. The results showed that calibrated diameter distributions were more accurate in terms of error index and the entire growing stock estimates. Compared with the best performer between the ABA and the ITD, calibrated diameter distributions decreased the relative RMSE of the estimated entire growing stock, saw log and pulpwood fractions by 2.81%, 3.05% and 7.73% points respectively. Calibration improved the estimation of pulpwood fraction significantly, resulting in a negligible bias of the estimated entire growing stock.

  15. Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

    International Nuclear Information System (INIS)

    Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias

    2008-01-01

    To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R 2 = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R 2 = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)

  16. Intra-fractional uncertainties in image-guided intensity-modulated radiotherapy (IMRT) of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Polat, Buelent; Guenther, Iris; Wilbert, Juergen; Goebel, Joachim; Sweeney, Reinhart A.; Flentje, Michael; Guckenberger, Matthias [Wuerzburg Univ. (Germany). Dept. of Radiation Oncology

    2008-12-15

    To evaluate intra-fractional uncertainties during intensity-modulated radiotherapy (IMRT) of prostate cancer. During IMRT of 21 consecutive patients, kilovolt (kV) cone-beam computed tomography (CBCT) images were acquired prior to and immediately after treatment: a total of 252 treatment fractions with 504 CBCT studies were basis of this analysis. The prostate position in anterior-posterior (AP) direction was determined using contour matching; patient set-up based on the pelvic bony anatomy was evaluated using automatic image registration. Internal variability of the prostate position was the difference between absolute prostate and patient position errors. Intra-fractional changes of prostate position, patient position, rectal distension in AP direction and bladder volume were analyzed. With a median treatment time of 16 min, intra-fractional drifts of the prostate were > 5 mm in 12% of all fractions and a margin of 6 mm was calculated for compensation of this uncertainty. Mobility of the prostate was independent from the bony anatomy with poor correlation between absolute prostate motion and motion of the bony anatomy (R{sup 2} = 0.24). A systematic increase of bladder filling by 41 ccm on average was observed; however, these changes did not influence the prostate position. Small variations of the prostate position occurred independently from intra-fractional changes of the rectal distension; a weak correlation between large internal prostate motion and changes of the rectal volume was observed (R{sup 2} = 0.55). Clinically significant intra-fractional changes of the prostate position were observed and margins of 6 mm were calculated for this intra-fractional uncertainty. Repeated or continuous verification of the prostate position may allow further margin reduction. (orig.)

  17. Characteristics of two-phase flows in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: schlegelj@mst.edu [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, 301 W 14th St., Rolla, MO 65401 (United States); Hibiki, T.; Ishii, M. [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907 (United States)

    2016-12-15

    Two-phase flows in large diameter channels have a great deal of importance in a wide variety of industrial applications. Nuclear systems, petroleum refineries, and chemical processes make extensive use of larger systems. Flows in such channels have very different properties from flows in smaller channels which are typically used in experimental research. In this paper, the various differences between flows in large and small channels are highlighted using the results of previous experimental and analytical research. This review is followed by a review of recent experiments in and model development for flows in large diameter channels performed by the authors. The topics of these research efforts range from void fraction and interfacial area concentration measurement to flow regime identification and modeling, drift-flux modeling for high void fraction conditions, and evaluation of interfacial area transport models for large diameter channels.

  18. Analytical incorporation of fractionation effects in probabilistic treatment planning for intensity-modulated proton therapy.

    Science.gov (United States)

    Wahl, Niklas; Hennig, Philipp; Wieser, Hans-Peter; Bangert, Mark

    2018-04-01

    We show that it is possible to explicitly incorporate fractionation effects into closed-form probabilistic treatment plan analysis and optimization for intensity-modulated proton therapy with analytical probabilistic modeling (APM). We study the impact of different fractionation schemes on the dosimetric uncertainty induced by random and systematic sources of range and setup uncertainty for treatment plans that were optimized with and without consideration of the number of treatment fractions. The APM framework is capable of handling arbitrarily correlated uncertainty models including systematic and random errors in the context of fractionation. On this basis, we construct an analytical dose variance computation pipeline that explicitly considers the number of treatment fractions for uncertainty quantitation and minimization during treatment planning. We evaluate the variance computation model in comparison to random sampling of 100 treatments for conventional and probabilistic treatment plans under different fractionation schemes (1, 5, 30 fractions) for an intracranial, a paraspinal and a prostate case. The impact of neglecting the fractionation scheme during treatment planning is investigated by applying treatment plans that were generated with probabilistic optimization for 1 fraction in a higher number of fractions and comparing them to the probabilistic plans optimized under explicit consideration of the number of fractions. APM enables the construction of an analytical variance computation model for dose uncertainty considering fractionation at negligible computational overhead. It is computationally feasible (a) to simultaneously perform a robustness analysis for all possible fraction numbers and (b) to perform a probabilistic treatment plan optimization for a specific fraction number. The incorporation of fractionation assumptions for robustness analysis exposes a dose to uncertainty trade-off, i.e., the dose in the organs at risk is increased for a

  19. Modified distribution parameter for churn-turbulent flows in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: jschlege@purdue.edu; Macke, C.J.; Hibiki, T.; Ishii, M.

    2013-10-15

    Highlights: • Void fraction data collected in pipe sizes up to 0.304 m using impedance void meters. • Flow conditions extend to transition between churn-turbulent and annular flow. • Flow regime identification results agree with previous studies. • A new model for the distribution parameter in churn-turbulent flow is proposed. -- Abstract: Two phase flows in large diameter channels are important in a wide range of industrial applications, but especially in analysis of nuclear reactor safety for the prediction of BWR behavior and safety analysis in PWRs. To remedy an inability of current drift-flux models to accurately predict the void fraction in churn-turbulent flows in large diameter pipes, extensive experiments have been performed in pipes with diameters of 0.152 m, 0.203 m and 0.304 m to collect area-averaged void fraction data using electrical impedance void meters. The standard deviation and skewness of the impedance meter signal have been used to characterize the flow regime and confirm previous flow regime transition results. By treating churn-turbulent flow as a transition between cap-bubbly dispersed flow and annular separated flow and using a linear ramp, the distribution parameter has been modified for churn-turbulent flow. The modified distribution parameter has been evaluated through comparison of the void fraction predicted by the drift-flux model and the measured void fraction.

  20. Modified distribution parameter for churn-turbulent flows in large diameter channels

    International Nuclear Information System (INIS)

    Schlegel, J.P.; Macke, C.J.; Hibiki, T.; Ishii, M.

    2013-01-01

    Highlights: • Void fraction data collected in pipe sizes up to 0.304 m using impedance void meters. • Flow conditions extend to transition between churn-turbulent and annular flow. • Flow regime identification results agree with previous studies. • A new model for the distribution parameter in churn-turbulent flow is proposed. -- Abstract: Two phase flows in large diameter channels are important in a wide range of industrial applications, but especially in analysis of nuclear reactor safety for the prediction of BWR behavior and safety analysis in PWRs. To remedy an inability of current drift-flux models to accurately predict the void fraction in churn-turbulent flows in large diameter pipes, extensive experiments have been performed in pipes with diameters of 0.152 m, 0.203 m and 0.304 m to collect area-averaged void fraction data using electrical impedance void meters. The standard deviation and skewness of the impedance meter signal have been used to characterize the flow regime and confirm previous flow regime transition results. By treating churn-turbulent flow as a transition between cap-bubbly dispersed flow and annular separated flow and using a linear ramp, the distribution parameter has been modified for churn-turbulent flow. The modified distribution parameter has been evaluated through comparison of the void fraction predicted by the drift-flux model and the measured void fraction

  1. Simulation calculation for the energy deposition profile and the transmission fraction of intense pulsed electron beam at various incident angles

    International Nuclear Information System (INIS)

    Yang Hailiang; Qiu Aici; Zhang Jiasheng; Huang Jianjun; Sun Jianfeng

    2002-01-01

    The incident angles have a heavy effect on the intense pulsed electron beam energy deposition profile, energy deposition fraction and beam current transmission fraction in material. The author presents electron beam energy deposition profile and energy deposition fraction versus electron energy (0.5-2.0 MeV), at various incident angles for three aluminum targets of various thickness via theoretical calculation. The intense pulsed electron beam current transmission fractions versus electron energy (0.4-1.4 MeV) at various incident angles for three thickness of carbon targets were also theoretically calculated. The calculation results indicate that the deposition energy in unit mass of material surface layer increase with the rise of electron beam incident angle, and electron beam with low incident angle (closer to normal incident angle) penetrates deeper into the target material. The electron beams deposit more energy in unit mass of material surface layer at 60 degree-70 degree incident angle

  2. Interfacial area concentration in gas–liquid bubbly to churn flow regimes in large diameter pipes

    International Nuclear Information System (INIS)

    Shen, Xiuzhong; Hibiki, Takashi

    2015-01-01

    Highlights: • A systematic method to predict interfacial area concentration (IAC) is presented. • A correlation for group 1 bubble void fraction is proposed. • Correlations of IAC and bubble diameter are developed for group 1 bubbles. • Correlations of IAC and bubble diameter are developed for group 2 bubbles. • The newly-developed two-group IAC model compares well with collected databases. - Abstract: This study performed a survey on existing correlations for interfacial area concentration (IAC) prediction and collected an IAC experimental database of two-phase flows taken under various flow conditions in large diameter pipes. Although some of these existing correlations were developed by partly using the IAC databases taken in the low-void-fraction two-phase flows in large diameter pipes, no correlation can satisfactorily predict the IAC in the two-phase flows changing from bubbly, cap bubbly to churn flow in the collected database of large diameter pipes. So this study presented a systematic way to predict the IAC for the bubbly-to-churn flows in large diameter pipes by categorizing bubbles into two groups (group 1: spherical or distorted bubble, group 2: cap bubble). A correlation was developed to predict the group 1 void fraction by using the void fraction for all bubble. The group 1 bubble IAC and bubble diameter were modeled by using the key parameters such as group 1 void fraction and bubble Reynolds number based on the analysis of Hibiki and Ishii (2001, 2002) using one-dimensional bubble number density and interfacial area transport equations. The correlations of IAC and bubble diameter for group 2 cap bubbles were developed by taking into account the characteristics of the representative bubbles among the group 2 bubbles and the comparison between a newly-derived drift velocity correlation for large diameter pipes and the existing drift velocity correlation of Kataoka and Ishii (1987) for large diameter pipes. The predictions from the newly

  3. Measurements of the diameter of the supernova SN 1987A

    International Nuclear Information System (INIS)

    Karovska, M.; Nisenson, P.; Standley, C.; Heathcote, S.R.

    1991-01-01

    Speckle interferometric measurements of the angular diameter of SN 1987A in the Large Magellanic Cloud, obtained at 664 days after the outburst are presented. Diameters were estimated with milliarcsec precision at 657 nm and 550 nm by fitting model visibility functions to the data corresponding to different intensity distributions for the supernova disk. Measurements made assuming a uniform intensity distribution were compared to the uniform disk measurements obtained from 30 days after the explosion. Diameter measurements obtained near the center of the H-alpha line are consistent with homologous expansion of the supernova shell with a mean velocity of 2850 km/s. The linear least-squares fit to the measurements obtained at other wavelengths from 260 days after the explosion yielded a somewhat lower mean expansion velocity. 8 refs

  4. Effects of alkalinity and salinity at low and high light intensity on hydrogen isotope fractionation of long-chain alkenones produced by Emiliania huxleyi

    Directory of Open Access Journals (Sweden)

    G. M. Weiss

    2017-12-01

    Full Text Available Over the last decade, hydrogen isotopes of long-chain alkenones have been shown to be a promising proxy for reconstructing paleo sea surface salinity due to a strong hydrogen isotope fractionation response to salinity across different environmental conditions. However, to date, the decoupling of the effects of alkalinity and salinity, parameters that co-vary in the surface ocean, on hydrogen isotope fractionation of alkenones has not been assessed. Furthermore, as the alkenone-producing haptophyte, Emiliania huxleyi, is known to grow in large blooms under high light intensities, the effect of salinity on hydrogen isotope fractionation under these high irradiances is important to constrain before using δDC37 to reconstruct paleosalinity. Batch cultures of the marine haptophyte E. huxleyi strain CCMP 1516 were grown to investigate the hydrogen isotope fractionation response to salinity at high light intensity and independently assess the effects of salinity and alkalinity under low-light conditions. Our results suggest that alkalinity does not significantly influence hydrogen isotope fractionation of alkenones, but salinity does have a strong effect. Additionally, no significant difference was observed between the fractionation responses to salinity recorded in alkenones grown under both high- and low-light conditions. Comparison with previous studies suggests that the fractionation response to salinity in culture is similar under different environmental conditions, strengthening the use of hydrogen isotope fractionation as a paleosalinity proxy.

  5. Effects of alkalinity and salinity at low and high light intensity on hydrogen isotope fractionation of long-chain alkenones produced by Emiliania huxleyi

    Science.gov (United States)

    Weiss, Gabriella M.; Pfannerstill, Eva Y.; Schouten, Stefan; Sinninghe Damsté, Jaap S.; van der Meer, Marcel T. J.

    2017-12-01

    Over the last decade, hydrogen isotopes of long-chain alkenones have been shown to be a promising proxy for reconstructing paleo sea surface salinity due to a strong hydrogen isotope fractionation response to salinity across different environmental conditions. However, to date, the decoupling of the effects of alkalinity and salinity, parameters that co-vary in the surface ocean, on hydrogen isotope fractionation of alkenones has not been assessed. Furthermore, as the alkenone-producing haptophyte, Emiliania huxleyi, is known to grow in large blooms under high light intensities, the effect of salinity on hydrogen isotope fractionation under these high irradiances is important to constrain before using δDC37 to reconstruct paleosalinity. Batch cultures of the marine haptophyte E. huxleyi strain CCMP 1516 were grown to investigate the hydrogen isotope fractionation response to salinity at high light intensity and independently assess the effects of salinity and alkalinity under low-light conditions. Our results suggest that alkalinity does not significantly influence hydrogen isotope fractionation of alkenones, but salinity does have a strong effect. Additionally, no significant difference was observed between the fractionation responses to salinity recorded in alkenones grown under both high- and low-light conditions. Comparison with previous studies suggests that the fractionation response to salinity in culture is similar under different environmental conditions, strengthening the use of hydrogen isotope fractionation as a paleosalinity proxy.

  6. Geometric interpretation of the ratio of overall diameter to rim crest diameter for lunar and terrestrial craters.

    Science.gov (United States)

    Siegal, B. S.; Wickman, F. E.

    1973-01-01

    An empirical linear relationship has been established by Pike (1967) between the overall diameter and the rim crest diameter for rimmed, flat-floored as well as bowl-shaped, lunar and terrestrial craters formed by impact and explosion. A similar relationship for experimentally formed fluidization craters has been established by Siegal (1971). This relationship is examined in terms of the geometry of the crater and the slope angles of loose materials. The parameter varies from 1.40 to 1.65 and is found to be dependent on mean interior flat floor radius, exterior and interior rim slope angles, angle of aperture of the crater cone, and the volume fraction of crater void accounted for in the rim. The range of the observed parameter can be understood in terms of simple crater geometry by realistic values of the five parameters.

  7. Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries

    NARCIS (Netherlands)

    Westenberg, J.J.M.; Geest, van der R.J.; Wasser, M.N.J.M.; Linden, van der E.L.; Walsum, van T.; Assen, van H.C.; Roos, de A.; Vanderschoot, J.; Reiber, J.H.C.

    2000-01-01

    In this study, the possibilities for quantification of vessel diameters of peripheral arteries in gadolinium contrast-enhanced magnetic resonance angiography (Gd CE MRA) were evaluated. Absolute vessel diameter measurements were assessed objectively and semi-automatically in maximum intensity

  8. Bubble behaviour and mean diameter in subcooled flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Zeitoun, O.; Shoukri, M. [McMaster Univ., Hamilton, Ontario (Canada)

    1995-09-01

    Bubble behaviour and mean bubble diameter in subcooled upward flow boiling in a vertical annular channel were investigated under low pressure and mass flux conditions. A high speed video system was used to visualize the subcooled flow boiling phenomenon. The high speed photographic results indicated that, contrary to the common understanding, bubbles tend to detach from the heating surface upstream of the net vapour generation point. Digital image processing technique was used to measure the mean bubble diameter along the subcooled flow boiling region. Data on the axial area-averaged void fraction distributions were also obtained using a single beam gamma densitometer. Effects of the liquid subcooling, applied heat flux and mass flux on the mean bubble size were investigated. A correlation for the mean bubble diameter as a function of the local subcooling, heat flux and mass flux was obtained.

  9. Positron annihilation characteristics in multi-wall carbon nanotubes with different average diameters

    International Nuclear Information System (INIS)

    Tuyen, L A; Khiem, D D; Phuc, P T; Kajcsos, Zs; Lázár, K; Tap, T D

    2013-01-01

    Positron lifetime spectroscopy was used to study multi-wall carbon nanotubes. The measurements were performed in vacuum on the samples having different average diameters. The positron lifetime values depend on the nanotube diameter. The results also show an influence of the nanotube diameter on the positron annihilation intensity on the nanotube surface. The change in the annihilation probability is described and interpreted by the modified diffusion model introducing the positron escape rate from the nanotubes to their external surface.

  10. Two-group interfacial area concentration correlations of two-phase flows in large diameter pipes

    International Nuclear Information System (INIS)

    Shen, Xiuzhong; Hibiki, Takashi

    2015-01-01

    The reliable empirical correlations and models are one of the important ways to predict the interfacial area concentration (IAC) in two-phase flows. However, up to now, no correlation or model is available for the prediction of the IAC in the two-phase flows in large diameter pipes. This study collected an IAC experimental database of two-phase flows taken under various flow conditions in large diameter pipes and presented a systematic way to predict the IAC for two-phase flows from bubbly, cap-bubbly to churn flow in large diameter pipes by categorizing bubbles into two groups (group-1: spherical and distorted bubble, group-2: cap bubble). Correlations were developed to predict the group-1 void fraction from the void fraction of all bubble. The IAC contribution from group-1 bubbles was modeled by using the dominant parameters of group-1 bubble void fraction and Reynolds number based on the parameter-dependent analysis of Hibiki and Ishii (2001, 2002) using one-dimensional bubble number density and interfacial area transport equations. A new drift velocity correlation for two-phase flow with large cap bubbles in large diameter pipes was derived in this study. By comparing the newly-derived drift velocity correlation with the existing drift velocity correlation of Kataoka and Ishii (1987) for large diameter pipes and using the characteristics of the representative bubbles among the group 2 bubbles, we developed the model of IAC and bubble size for group 2 cap bubbles. The developed models for estimating the IAC are compared with the entire collected database. A reasonable agreement was obtained with average relative errors of ±28.1%, ±54.4% and ±29.6% for group 1, group 2 and all bubbles respectively. (author)

  11. Evaluation of intra- and inter-fraction movement of the cervix during intensity modulated radiation therapy

    International Nuclear Information System (INIS)

    Haripotepornkul, Nora H.; Nath, Sameer K.; Scanderbeg, Daniel; Saenz, Cheryl; Yashar, Catheryn M.

    2011-01-01

    Background and purpose: To assess the degree of intra- and inter-fraction cervical motion throughout a course of intensity modulated radiation therapy (IMRT) for cervical cancer patients. Materials and methods: A retrospective study of 10 women with stage 1B1-3B cervical cancer diagnosed from September 2007 to July 2008 was conducted. All patients were treated with chemoradiation using IMRT followed by intracavitary brachytherapy. Pretreatment, patients had 2 seeds placed at a depth of 10 mm into the cervix. On-Board Imaging (OBI) was used to obtain anterior/posterior (AP) and lateral X-rays before and after each treatment. OBI images were rigidly aligned to baseline digitally reconstructed radiographs (DRRs), and movement of cervical seeds was determined in the lateral, vertical, and AP directions. Mean differences in cervical seed position and standard error of the mean (SEM) were calculated. Results: A total of 922 images were reviewed, with approximately 90 images per patient. The mean intra-fractional movement in cervical seed position in the lateral, vertical, and AP directions were 1.6 mm (SD ± 2.0), 2.6 mm (SD ± 2.4), and 2.9 mm (SD ± 2.7), respectively, with a range from 0 to 15 mm for each direction. The mean inter-fractional movement in the lateral, vertical, and AP directions were 1.9 mm (SD ± 1.9), 4.1 mm (SD ± 3.2), and 4.2 mm (SD ± 3.5), respectively, with a range from 0 to 18 mm for each direction. Conclusions: This is the first study to assess intra- and inter-fractional movement of the cervix using daily imaging before and after each fraction. Within and between radiation treatments, cervical motion averages approximately 3 mm in any given direction. However, maximal movement of the cervix can be as far as 18 mm from baseline. This wide range of motion needs to be accounted for when generating planning treatment volumes.

  12. Ultrasonic determination of interfacial area, void fraction and Sauter mean diameter in bubbly flow

    International Nuclear Information System (INIS)

    Bensler, Henri-Paul

    1990-01-01

    In this research thesis, the author shows that it is possible to determine, by means of a single measurement, the interface surface, the vacuum rate, and the Sauter mean diameter in a bubbly water-air flow. The developed technique relies on the measurement of the attenuation of an ultrasound beam by the two-phase medium, and on the use of broadband transducers associated with a multi-frequency screening method. Tests in standing water or in forced convection are performed in ducts with a square cross section with a side of 40, 80, or 120 mm. Values obtained with ultrasounds are compared with those determined by using photographs (interface surfaces, Sauter diameters) or by using a gauge pressure, or by using X rays (vacuum rate). This method based on ultrasound attenuation reveals to be simple and in good agreement with reference methods [fr

  13. [Effects of precipitation intensity on soil organic carbon fractions and their distribution under subtropical forests of South China].

    Science.gov (United States)

    Chen, Xiao-mei; Liu, Ju-xiu; Deng, Qi; Chu, Guo-wei; Zhou, Guo-yi; Zhang, De-qiang

    2010-05-01

    From December 2006 to June 2008, a field experiment was conducted to study the effects of natural precipitation, doubled precipitation, and no precipitation on the soil organic carbon fractions and their distribution under a successional series of monsoon evergreen broad-leaf forest, pine and broad-leaf mixed forest, and pine forest in Dinghushan Mountain of Southern China. Different precipitation treatments had no significant effects on the total organic carbon (TOC) concentration in the same soil layer under the same forest type (P > 0.05). In treatment no precipitation, particulate organic carbon (POC) and light fraction organic carbon (LFOC) were mainly accumulated in surface soil layer (0-10 cm); but in treatments natural precipitation and doubled precipitation, the two fractions were infiltrated to deeper soil layers. Under pine forest, soil readily oxidizable organic carbon (ROC) was significantly higher in treatment no precipitation than in treatments natural precipitation and doubled precipitation (P organic carbon storage. Precipitation intensity less affected TOC, but had greater effects on the labile components POC, ROC, and LFOC.

  14. Convex reformulation of biologically-based multi-criteria intensity-modulated radiation therapy optimization including fractionation effects.

    Science.gov (United States)

    Hoffmann, Aswin L; den Hertog, Dick; Siem, Alex Y D; Kaanders, Johannes H A M; Huizenga, Henk

    2008-11-21

    Finding fluence maps for intensity-modulated radiation therapy (IMRT) can be formulated as a multi-criteria optimization problem for which Pareto optimal treatment plans exist. To account for the dose-per-fraction effect of fractionated IMRT, it is desirable to exploit radiobiological treatment plan evaluation criteria based on the linear-quadratic (LQ) cell survival model as a means to balance the radiation benefits and risks in terms of biologic response. Unfortunately, the LQ-model-based radiobiological criteria are nonconvex functions, which make the optimization problem hard to solve. We apply the framework proposed by Romeijn et al (2004 Phys. Med. Biol. 49 1991-2013) to find transformations of LQ-model-based radiobiological functions and establish conditions under which transformed functions result in equivalent convex criteria that do not change the set of Pareto optimal treatment plans. The functions analysed are: the LQ-Poisson-based model for tumour control probability (TCP) with and without inter-patient heterogeneity in radiation sensitivity, the LQ-Poisson-based relative seriality s-model for normal tissue complication probability (NTCP), the equivalent uniform dose (EUD) under the LQ-Poisson model and the fractionation-corrected Probit-based model for NTCP according to Lyman, Kutcher and Burman. These functions differ from those analysed before in that they cannot be decomposed into elementary EUD or generalized-EUD functions. In addition, we show that applying increasing and concave transformations to the convexified functions is beneficial for the piecewise approximation of the Pareto efficient frontier.

  15. Factors affecting particle retention in thermal field-flow fractionation

    African Journals Online (AJOL)

    colloidal material is illustrated through the evaluation of thermal diffusion coefficient of PS ... Field-flow fractionation (FFF) is a separation method introduced by Giddings in 1966 [1]. It is a ... no stationary phase is used in FFF. .... that the inversion diameter (diameter at which order of retention changes) can be shifted up or.

  16. Pilot study: safety and effectiveness of simple ultrasound-guided high-intensity focused ultrasound ablating uterine leiomyoma with a diameter greater than 10 cm.

    Science.gov (United States)

    Hou, Ruijie; Wang, Liwei; Li, Shaoping; Rong, Fengmin; Wang, Yuanyuan; Qin, Xuena; Wang, Shijin

    2018-02-01

    The study aimed to prospectively investigate whether uterine leiomyoma greater than 10 cm in diameter could be treated with simple ultrasound-guided high-intensity focused ultrasound (USgHIFU) in one-time treatment. A total of 36 patients with 36 symptomatic uterine leiomyoma greater than 10 cm in diameter who underwent simple USgHIFU treatment alone were analysed. Enhanced MRI was performed before and after HIFU treatment, and all patients had follow-up for 6 months after treatment. Symptom severity scores, treatment time, treatment speed, ablation rate, energy effect ratio, uterine leiomyoma regression rate, adverse events, liver and kidney functions, coagulation function and routine blood count were included in the study endpoints. The mean diameter of uterine leiomyoma was 11.2 ± 1.3 cm (10.0-14.3 cm). The median treatment time and treatment speed were 104.0 min (90.0-140.0 min) and 118.8 cm 3  h -1  (86.2-247.1 cm 3  h -1 ), respectively. The ablation rate of uterine leiomyoma was 71.9 ± 20.4% (32.1-100.0%), and the regression rate of uterine leiomyoma was 40.8 ± 7.5% (25.6-59.9%) at 6 months after treatment. The mean symptom severity scores decreased by an average of approximately 8.6 ± 2.3 (5-14) points. There were no significant changes in haemogram and blood chemical indexes of patients, except for the transient elevation of aspartate aminotransferase, total bilirubin and white blood cells after treatment. No serious adverse reactions occurred. According to our preliminary results, simple USgHIFU is a safe and effective single-treatment method of treating uterine leiomyoma greater than 10 cm in diameter and is an almost innocuous alternative therapeutic strategy. Advances in knowledge: The conclusions indicate simple USgHIFU is safe and effective as one-time treatment of uterine leiomyoma greater than 10 cm in diameter, it could be a promising therapeutic strategy.

  17. Fractional variational principles in action

    Energy Technology Data Exchange (ETDEWEB)

    Baleanu, Dumitru [Department of Mathematics and Computer Science, Faculty of Art and Sciences, Cankaya University, 06530 Ankara (Turkey); Institute of Space Sciences, PO Box MG-23, R 76900, Magurele-Bucharest (Romania)], E-mail: dumitru@cankaya.edu.tr

    2009-10-15

    The fractional calculus has gained considerable importance in various fields of science and engineering, especially during the last few decades. An open issue in this emerging field is represented by the fractional variational principles area. Therefore, the fractional Euler-Lagrange and Hamilton equations started to be examined intensely during the last decade. In this paper, we review some new trends in this field and we discuss some of their potential applications.

  18. Pore diameter control of anodic aluminum oxide with ordered array of nanopores

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Allen; Yang, Yong-Feng [Department of Chemical Engineering, National Tsing Hua University, Hsin-Chu, 30013 (China); Hu, Chi-Chang [Department of Chemical Engineering, National Tsing Hua University, Hsin-Chu 401 (China); Department of Chemical Engineering, National Chung Cheng University, Chia-Yi 621 (China); Lin, Chi-Cheng [Department of Chemical Engineering, National Chung Cheng University, Chia-Yi 621 (China)

    2008-01-01

    Highly uniform, self-ordered anodic aluminum oxide (AAO) with an ordered nanoporous array can be effectively formed from industrially pure (99.5%) aluminum sheets through an anodizing program in a mixture solution of sulfuric and oxalic acids. The influences of anodizing variables, such as applied voltage, solution temperature, oxalic acid concentration, agitation rate, and sulfuric acid concentration, on the average pore diameter of AAO were systematically investigated using fractional factorial design (FFD). The applied voltage, and sulfuric acid concentration were found to be the key factors affecting the pore diameter of AAO films in the FFD study. The pore diameter of AAO is regularly increased from ca. 50 to 150 nm when the applied voltage and the concentration of sulfuric acid are gradually increased from 53 to 80 V and from 3.5 to 8 M, respectively. Fine tuning of the pore diameter for AAO films with an ordered, nanoporous, arrayed structure from industrially pure aluminum sheets can be achieved. (author)

  19. Improvement of estimation method of two-phase flow in a large diameter pipe. 2. Development of mechanistic interfacial drag force model

    International Nuclear Information System (INIS)

    Okawa, Tomio; Yoneda, Kimitoshi

    1998-01-01

    It is experimentally clarified that behavior of gas-liquid two-phase flow in large diameter pipe is different from one occurred in small diameter pipe. However, no special model for large diameter pipe is used in existing nuclear reactor safety analysis codes. In the present study, detailed investigation about the two-phase flow model used in the safety analysis was carried out to specify the physical phenomena which should be modeled more precisely. Based on the investigation, steam-water two-phase flow experiments using large diameter pipe was conducted to obtain new models. As a result, new evaluation methods for bubble size, heterogeneous distribution of void fraction, and wake formed behind bubble were developed. These new models were applied to the prediction of steam-water two-phase flow experiments using large diameter pipes to clarify their validity. It was consequently demonstrated that the accuracy of the numerical solution is remarkably improved not only for the experiment used for model development but also for the experiment where the pipe diameter, pressure, velocities, void fraction are different. (author)

  20. Gas phase synthesis of non-bundled, small diameter single-walled carbon nanotubes with near-armchair chiralities

    Energy Technology Data Exchange (ETDEWEB)

    Mustonen, K.; Laiho, P.; Kaskela, A.; Zhu, Z.; Reynaud, O.; Houbenov, N.; Tian, Y.; Jiang, H.; Kauppinen, E. I., E-mail: esko.kauppinen@aalto.fi [Department of Applied Physics, Aalto University School of Science, P.O. Box 15100, FI-00076 Aalto (Finland); Susi, T. [Faculty of Physics, University of Vienna, Boltzmanngasse 5, A-1090 Vienna (Austria); Nasibulin, A. G. [Department of Applied Physics, Aalto University School of Science, P.O. Box 15100, FI-00076 Aalto (Finland); Skolkovo Institute of Science and Technology, Nobel str. 3, 143026 (Russian Federation); Saint-Petersburg State Polytechnical University, 29 Polytechniheskaya st., St. Petersburg, 195251 (Russian Federation)

    2015-07-06

    We present a floating catalyst synthesis route for individual, i.e., non-bundled, small diameter single-walled carbon nanotubes (SWCNTs) with a narrow chiral angle distribution peaking at high chiralities near the armchair species. An ex situ spark discharge generator was used to form iron particles with geometric number mean diameters of 3–4 nm and fed into a laminar flow chemical vapour deposition reactor for the continuous synthesis of long and high-quality SWCNTs from ambient pressure carbon monoxide. The intensity ratio of G/D peaks in Raman spectra up to 48 and mean tube lengths up to 4 μm were observed. The chiral distributions, as directly determined by electron diffraction in the transmission electron microscope, clustered around the (n,m) indices (7,6), (8,6), (8,7), and (9,6), with up to 70% of tubes having chiral angles over 20°. The mean diameter of SWCNTs was reduced from 1.10 to 1.04 nm by decreasing the growth temperature from 880 to 750 °C, which simultaneously increased the fraction of semiconducting tubes from 67% to 80%. Limiting the nanotube gas phase number concentration to ∼10{sup 5 }cm{sup −3} prevented nanotube bundle formation that is due to collisions induced by Brownian diffusion. Up to 80% of 500 as-deposited tubes observed by atomic force and transmission electron microscopy were individual. Transparent conducting films deposited from these SWCNTs exhibited record low sheet resistances of 63 Ω/□ at 90% transparency for 550 nm light.

  1. DESIGN OF PARTICULATE MATERIAL COMPACTOR ROLLS DIAMETER

    Directory of Open Access Journals (Sweden)

    Peter Peciar

    2017-09-01

    Full Text Available At present, in a period of an industrial expansion great emphasis is placed on the environment. That means aiming for a reduced energy consumption, and also lessening dustiness from very fine powder material. This category also includes particulate material agglomeration processes. Because this process is very energy-intensive, it is necessary to correctly design these devices. The aim of this paper is to focus on a theoretical design of a production compactor with the rolls diameter for an experimental particulate material, based on Johanson’s theory and experimentally measured material properties. The material used for experimental measurements was an NPK-based industrial fertilizer consisting of several components. The results of this paper is the dependence of the ratio of the maximum compression pressure to the initial compression pressure from the rolls diameter of the proposed compactor.

  2. Correlation of inferior vena cava (ivc) diameter and central venous pressure (cvp) for fluid monitoring in icu

    International Nuclear Information System (INIS)

    Khalil, A.; Hayat, A.

    2015-01-01

    To determine intravascular fluid status in critically ill patients using inferior vena cava diameter and correlating it with central venous pressure. Study Design: Cross sectional study. Place and Duration of Study: Intensive care department, Military Hospital Rawalpindi from Jan 2013 to Aug 2013. Material and Methods: We included 115 adult patients of both genders in age range of 18 to 87 years by consecutive sampling admitted in intensive care unit. Ultrasound guided IVC diameter was assessed in supine patients. Data was simultaneously collected from the CVP catheter. Variables included in study were age, gender, CVP, IVC diameter. Results: CVP ranged from -4 to 26 cm H/sub 2/O with mean of 8 cm H/sub 2/O (SD = 6.24). Mean IVC diameters increased with increase in CVP. Correlation between CVP and max IVC diameter was moderate and significant (r = 0.53, p < 0.001). Correlation between CVP and min IVC diameter was also moderate and significant (r = 0.58, p < 0.001). Conclusion: A simple bedside sonography of inferior vena cava diameter correlates well with extremes of CVP values and can be helpful in assessing intravascular fluid status in these patients. (author)

  3. Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motions

    International Nuclear Information System (INIS)

    Lomax, A J

    2008-01-01

    Simple tools for studying the effects of inter-fraction and inter-field motions on intensity modulated proton therapy (IMPT) plans have been developed, and have been applied to both 3D and distal edge tracking (DET) IMPT plans. For the inter-fraction motion, we have investigated the effects of misaligned density heterogeneities, whereas for the inter-field motion analysis, the effects of field misalignment on the plans have been assessed. Inter-fraction motion problems have been analysed using density differentiated error (DDE) distributions, which specifically show the additional problems resulting from misaligned density heterogeneities for proton plans. Likewise, for inter-field motion, we present methods for calculating motion differentiated error (MDE) distributions. DDE and MDE analysis of all plans demonstrate that the 3D approach is generally more robust to both inter-fraction and inter-field motions than the DET approach, but that strong in-field dose gradients can also adversely affect a plan's robustness. An important additional conclusion is that, for certain IMPT plans, even inter-fraction errors cannot necessarily be compensated for by the use of a simple PTV margins, implying that more sophisticated tools need to be developed for uncertainty management and assessment for IMPT treatments at the treatment planning level

  4. Pupil Diameter Does Not Correlate with Fixation Duration - or Does It?

    DEFF Research Database (Denmark)

    Lykke Jakobsen, Arnt; Carl, Michael; Elming, Jakob

    2013-01-01

    A number of pupillometric studies have suggested that dynamic differences in pupil diameter correlate with dierent levels of cognitive intensity or excitement. Other studies have suggested a similar correlation between fixation duration and cognitive effort. Since both methodologies for hypothesi...

  5. Fractional Bateman—Feshbach Tikochinsky Oscillator

    Science.gov (United States)

    Dumitru, Baleanu; Jihad, H. Asad; Ivo, Petras

    2014-02-01

    In the last few years the numerical methods for solving the fractional differential equations started to be applied intensively to real world phenomena. Having these things in mind in this manuscript we focus on the fractional Lagrangian and Hamiltonian of the complex Bateman—Feshbach Tikochinsky oscillator. The numerical analysis of the corresponding fractional Euler-Lagrange equations is given within the Grünwald—Letnikov approach, which is power series expansion of the generating function.

  6. Influence of intense scavenging on Pa-Th fractionation in the wake of Kerguelen Island (Southern Ocean)

    International Nuclear Information System (INIS)

    Venchiarutti, C.; Roy-Barman, M.; Freydier, R.; Van Beek, P.; Souhaut, M.; Jeandel, C.

    2011-01-01

    Dissolved and particulate excess 230 Th and 231 Pa concentrations (noted 230 Th xs and 231 Pa xs respectively) and 231 Pa xs / 230 Th xs activity ratios were investigated on and out of the Kerguelen plateau (Southern Ocean) in the framework of the Kerguelen Ocean and Plateau compared Study project in order to better understand the influence of particle flux and particle chemistry and advection on the scavenging of 231 Pa. In the wake of Kerguelen, particulate 231 Pa xs is relatively abundant compared to its content in the dissolved phase. This, together with the low fractionation observed between 230 Th and 231 Pa (F Th/Pa ranging from 0.06 ± 0.01 to 1.6 ± 0.2) reflects the domination of the biogenic silica in the particle pool. Along the eastern escarpment of the Kerguelen plateau, the strong 231 Pa xs horizontal gradient in the deep waters highlights the intense removal of 231 Pa at depth, as already observed for 230 Th xs . This local boundary scavenging was attributed to re-suspension of opal-rich particles by nepheloid layers, resulting in fractionation factors F Th/Pa ≤ 1 along the Kerguelen plateau slope. Therefore, both the composition (biogenic opal) and the flux (intense along the margin) of particles control the scavenging of the two radionuclides in the Kerguelen wake. The modelling of 231 Pa distribution with an advection-scavenging model demonstrates that lateral advection of open ocean water on the Kerguelen plateau could supply most of the 231 Pa, which is then efficiently scavenged on the highly productive plateau, as previously proposed for 230 Th xs . It stresses that lateral advection can play a significant role in the overall budget of particle reactive trace elements in a coastal-open ocean system. (authors)

  7. Prediction of pool void fraction by new drift flux correlation

    International Nuclear Information System (INIS)

    Kataoka, I.; Ishii, M.

    1986-06-01

    A void fraction for a bubbling or boiling pool system is one of the important parameters in analyzing heat and mass transfer processes. Using the drift flux formulation, correlations for the pool void fraction have been developed in collaboration with a large number of experimental data. It has been found that the drift velocity in a pool system depends upon vessel diameter, system pressure, gas flux and fluid physical properties. The results show that the relative velocity and void fraction can be quite different from those predicted by conventional correlations. In terms of the rise velocity, four different regimes are identified. These are bubbly, churn-turbulent, slug and cap bubble regimes. The present correlations are shown to agree with the experimental data over wide ranges of parameters such as vessel diameter, system pressure, gas flux and physical properties. 39 refs., 41 figs

  8. Solar variability observed through changes in solar figure and mean diameter

    International Nuclear Information System (INIS)

    Hill, H.A.

    1984-01-01

    The objective of the project is to detect and monitor climatically significant solar variability by accurate monitoring of the associated variability in solar shape and diameter. The observing program for this project was initiated in 1981. Solar diameter measurements have been taken and data reduction programs for these measurements have been developed. Theoretical analysis of the expected change in the intensity from the solar atmosphere to a given mechanial driving has progressed to the extent that changes in the solar diameter can be related to the associated change in the solar luminosity. An absolute calibration system for the telescope has been constructed and is currently being tested. A proposal is made for the continuation of the work in each of these areas

  9. Fractional Bateman—Feshbach Tikochinsky Oscillator

    International Nuclear Information System (INIS)

    Baleanu, Dumitru; Asad, Jihad H.; Petras Ivo

    2014-01-01

    In the last few years the numerical methods for solving the fractional differential equations started to be applied intensively to real world phenomena. Having these things in mind in this manuscript we focus on the fractional Lagrangian and Hamiltonian of the complex Bateman—Feshbach Tikochinsky oscillator. The numerical analysis of the corresponding fractional Euler-Lagrange equations is given within the Grünwald—Letnikov approach, which is power series expansion of the generating function. (physics of elementary particles and fields)

  10. A clustering analysis of lipoprotein diameters in the metabolic syndrome

    Directory of Open Access Journals (Sweden)

    Frazier-Wood Alexis C

    2011-12-01

    Full Text Available Abstract Background The presence of smaller low-density lipoproteins (LDL has been associated with atherosclerosis risk, and the insulin resistance (IR underlying the metabolic syndrome (MetS. In addition, some research has supported the association of very low-, low- and high-density lipoprotein (VLDL HDL particle diameters with components of the metabolic syndrome (MetS, although this has been the focus of less research. We aimed to explore the relationship of VLDL, LDL and HDL diameters to MetS and its features, and by clustering individuals by their diameters of VLDL, LDL and HDL particles, to capture information across all three fractions of lipoprotein into a unified phenotype. Methods We used nuclear magnetic resonance spectroscopy measurements on fasting plasma samples from a general population sample of 1,036 adults (mean ± SD, 48.8 ± 16.2 y of age. Using latent class analysis, the sample was grouped by the diameter of their fasting lipoproteins, and mixed effects models tested whether the distribution of MetS components varied across the groups. Results Eight discrete groups were identified. Two groups (N = 251 were enriched with individuals meeting criteria for the MetS, and were characterized by the smallest LDL/HDL diameters. One of those two groups, one was additionally distinguished by large VLDL, and had significantly higher blood pressure, fasting glucose, triglycerides, and waist circumference (WC; P Conclusions While small LDL diameters remain associated with IR and the MetS, the occurrence of these in conjunction with a shift to overall larger VLDL diameter may identify those with the highest fasting glucose, TG and WC within the MetS. If replicated, the association of this phenotype with more severe IR-features indicated that it may contribute to identifying of those most at risk for incident type II diabetes and cardiometabolic disease.

  11. The effects of different mixing intensities during anaerobic digestion of the organic fraction of municipal solid waste

    International Nuclear Information System (INIS)

    Lindmark, Johan; Eriksson, Per; Thorin, Eva

    2014-01-01

    Highlights: • Effects of mixing on the anaerobic digestion of municipal solid waste. • Digestion of fresh substrate and post-digestion at three mixing intensities were evaluated. • Mixing performed at 150 RPM, 25 RPM and minimally intermittently. • Increased biogas production rates and yields at lower mixing intensities. - Abstract: Mixing inside an anaerobic digester is often continuous and is not actively controlled. The selected mixing regime can however affect both gas production and the energy efficiency of the biogas plant. This study aims to evaluate these effects and compare three different mixing regimes, 150 RPM and 25 RPM continuous mixing and minimally intermittent mixing for both digestion of fresh substrate and post-digestion of the organic fraction of municipal solid waste. The results show that a lower mixing intensity leads to a higher biogas production rate and higher total biogas production in both cases. 25 RPM continuous mixing and minimally intermittent mixing resulted in similar biogas production after process stabilization, while 150 RPM continuous mixing resulted in lower production throughout the experiment. The lower gas production at 150 RPM could not be explained by the inhibition of volatile fatty acids. Cumulative biogas production until day 31 was 295 ± 2.9, 317 ± 1.9 and 304 ± 2.8 N ml/g VS added during digestion of fresh feed and 113 ± 1.3, 134 ± 1.1 and 130 ± 2.3 N ml/g VS added during post digestion for the 150 RPM, 25 RPM and minimally mixed intensities respectively. As well as increasing gas production, optimal mixing can improve the energy efficiency of the anaerobic digestion process

  12. The effects of different mixing intensities during anaerobic digestion of the organic fraction of municipal solid waste

    Energy Technology Data Exchange (ETDEWEB)

    Lindmark, Johan, E-mail: Johan.lindmark@mdh.se; Eriksson, Per; Thorin, Eva, E-mail: Eva.Thorin@mdh.se

    2014-08-15

    Highlights: • Effects of mixing on the anaerobic digestion of municipal solid waste. • Digestion of fresh substrate and post-digestion at three mixing intensities were evaluated. • Mixing performed at 150 RPM, 25 RPM and minimally intermittently. • Increased biogas production rates and yields at lower mixing intensities. - Abstract: Mixing inside an anaerobic digester is often continuous and is not actively controlled. The selected mixing regime can however affect both gas production and the energy efficiency of the biogas plant. This study aims to evaluate these effects and compare three different mixing regimes, 150 RPM and 25 RPM continuous mixing and minimally intermittent mixing for both digestion of fresh substrate and post-digestion of the organic fraction of municipal solid waste. The results show that a lower mixing intensity leads to a higher biogas production rate and higher total biogas production in both cases. 25 RPM continuous mixing and minimally intermittent mixing resulted in similar biogas production after process stabilization, while 150 RPM continuous mixing resulted in lower production throughout the experiment. The lower gas production at 150 RPM could not be explained by the inhibition of volatile fatty acids. Cumulative biogas production until day 31 was 295 ± 2.9, 317 ± 1.9 and 304 ± 2.8 N ml/g VS added during digestion of fresh feed and 113 ± 1.3, 134 ± 1.1 and 130 ± 2.3 N ml/g VS added during post digestion for the 150 RPM, 25 RPM and minimally mixed intensities respectively. As well as increasing gas production, optimal mixing can improve the energy efficiency of the anaerobic digestion process.

  13. Ultracentrifugation for ultrafine nanodiamond fractionation

    Science.gov (United States)

    Koniakhin, S. V.; Besedina, N. A.; Kirilenko, D. A.; Shvidchenko, A. V.; Eidelman, E. D.

    2018-01-01

    In this paper we propose a method for ultrafine fractionation of nanodiamonds using the differential centrifugation in the fields up to 215000g. The developed protocols yield 4-6 nm fraction giving main contribution to the light scattering intensity. The desired 4-6 nm fraction can be obtained from various types of initial nanodiamonds: three types of detonation nanodiamonds differing in purifying methods, laser synthesis nanodiamonds and nanodiamonds made by milling. The characterization of the obtained hydrosols was conducted with Dynamic Light Scattering, Zeta potential measurements, powder XRD and TEM. According to powder XRD and TEM data ultracentrifugation also leads to a further fractionation of the primary diamond nanocrystallites in the hydrosols from 4 to 2 nm.

  14. Colloidal transport of uranium in soil: Size fractionation and characterization by field-flow fractionation-multi-detection

    International Nuclear Information System (INIS)

    Claveranne-Lamolere, C.; Lespes, G.; Dubascoux, St.; Potin-Gautier, M.; Claveranne-Lamolere, C.; Aupiais, J.; Pointurier, F.

    2009-01-01

    The aim of this study was to characterize colloids associated with uranium by using an on-line fractionation/multi-detection technique based on asymmetrical flow field-flow fractionation (As-Fl-FFF) hyphenated with UV detector, multi angle laser light scattering (MALLS) and inductively coupling plasma-mass spectrometry (ICP-MS). Moreover, thanks to the As-Fl-FFF, the different colloidal fractions were collected and characterized by a total organic carbon analyzer (TOC). Thus it is possible to determine the nature (organic or inorganic colloids), molar mass, size (gyration and hydrodynamic radii) and quantitative uranium distribution over the whole colloidal phase. In the case of the site studied, two populations are highlighted. The first population corresponds to humic-like substances with a molar mass of (1500 ± 300) g mol -1 and a hydrodynamic diameter of (2. 0 ± 0. 2) nm. The second one has been identified as a mix of carbonated nano-particles or clays with organic particles (aggregates and/or coating of the inorganic particles) with a size range hydrodynamic diameter between 30 and 450 nm. Each population is implied in the colloidal transport of uranium: maximum 1% of the uranium content in soil leachate is transported by the colloids in the site studied, according to the depth in the soil. Indeed, humic substances are the main responsible of this transport in sub-surface conditions whereas nano-particles drive the phenomenon in depth conditions. (authors)

  15. Failure Diameter Resolution Study

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-19

    Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

  16. Gamma ray scanning as troubleshooting tool for unusual and large diameter refinery vacuum columns

    International Nuclear Information System (INIS)

    Sarkar, T.K.; Chawla, R.; Banik, S.; Chopra, S.J.; Singh, G.; Pant, H.J.; Sreeramakrishnan, P.; Dhar, D.C.; Pushpangathan, P.N.; Sharma, V.K.

    1997-01-01

    Gamma scanning of trayed and packed columns is widely used to obtain density profiles and identify on-line problems such as: damaged tray or packing, foaming, flooding, maldistribution, weeping and entrainment, etc. However, scanning of large diameter tray or packed columns requires expertise in handling high intensity gamma sources along with thorough understanding of distillation engineering. Engineers India Limited and the Bhabha Atomic Research Centre undertook scanning of two such large diameter (8.4 m and 7.4 m) trayed and packed refinery vacuum distillation columns and successfully diagnosed the problems and suggested remedial actions. Radiography testing of small diameter columns can be used to confirm gamma scanning results. One such example for ammonia separator column is given

  17. Measurement of the local void fraction in two-phase air-water flow with a hot-film anemometer

    International Nuclear Information System (INIS)

    Delhaye, J.

    1968-01-01

    The experimental knowledge of the local void-fraction is basic for the derivation of the constitutive equations of two-phase flows. This report deals with measurements of the local void-fraction based on the use of a constant temperature hot-film anemometer associated with a multichannel analyser. After determining the void-fraction profile along a diameter of a vertical pipe (40 mm I.D.), in which air and water flow upwards, we compare the void-fraction averaged over the diameter with the average value measured directly by a γ-ray method. Two runs were made in bubble flow and a third in slug flow. The two methods give results in a good agreement especially for bubble flow. The void-fraction averaged over the cross-section was also calculated from the different profiles and compared in a good manner with the experimental results of R. ROUMY. For bubble flow we verified the theory of S.G. BANKOFF about the shape of the void-fraction profiles. (author) [fr

  18. Influence of intense scavenging on Pa-Th fractionation in the wake of Kerguelen Island (Southern Ocean

    Directory of Open Access Journals (Sweden)

    C. Venchiarutti

    2011-11-01

    Full Text Available Dissolved and particulate excess 230Th and 231Pa concentrations (noted 230Thxs and 231Paxs respectively and 231Paxs/230Thxs activity ratios were investigated on and out of the Kerguelen plateau (Southern Ocean in the framework of the Kerguelen Ocean and Plateau compared Study project in order to better understand the influence of particle flux and particle chemistry and advection on the scavenging of 231Pa.

    In the wake of Kerguelen, particulate 231Paxs is relatively abundant compared to its content in the dissolved phase. This, together with the low fractionation observed between 230Th and 231Pa (FTh/Pa ranging from 0.06 ± 0.01 to 1.6 ± 0.2 reflects the domination of the biogenic silica in the particle pool.

    Along the eastern escarpment of the Kerguelen plateau, the strong 231Paxs horizontal gradient in the deep waters highlights the intense removal of 231Pa at depth, as already observed for 230Thxs. This local boundary scavenging was attributed to re-suspension of opal-rich particles by nepheloid layers, resulting in fractionation factors FTh/Pa ≤ 1 along the Kerguelen plateau slope. Therefore, both the composition (biogenic opal and the flux (intense along the margin of particles control the scavenging of the two radionuclides in the Kerguelen wake.

    The modelling of 231Pa distribution with an advection-scavenging model demonstrates that lateral advection of open ocean water on the Kerguelen plateau could supply most of the 231Pa, which is then efficiently scavenged on the highly productive plateau, as previously proposed for 230Thxs. It stresses that lateral advection can play a significant role in the overall

  19. Influence of the pipe diameter on the structure of the gas-liquid interface in a vertical two-phase pipe flow

    International Nuclear Information System (INIS)

    Prasser, H. M.; Beyer, M.; Boettger, A.; Carl, H.; Lucas, D.; Schaffrath, A.; Schutz, P.; Weiss, F. P.; Zschau, J.

    2003-01-01

    Two-phase flow tests in a 194.1 mm diameter vertical pipe (DN200) with an air-water mixture are reported. Close to the upper end of a 9 m tall test section a wire-mesh sensor is installed that delivers instantaneous void fraction distributions over the entire cross section with time resolution of 2500 frames per second. The sensor disposes of 64 x 64 measuring points, which corresponds to a spatial resolution of 3 mm. Beside an fast flow visualisations, void-fraction profiles and bubble size distributions were obtained. Earlier, similar experiments were carried out in a pipe of 51.2 mm inner diameter (DN50). A comparison of the data from the two different facilities allows to study the scaling effects on void fraction profiles, bubbles size distributions and the flow patterns. In the small pipe, the increase of the air flow rate leads to a transition from bubbly via slug to churn turbulent flow. The transition to slug flow is accompanied by the appearance of a second peak in the bubble size distribution that corresponds to the class of large Taylor bubbles. A similar qualitative behaviour was found in the large pipe, though the large bubble fraction has a significantly bigger mean diameter at identical superficial velocities, the peak is less tall but wider. Bubbles move more freely than in the small pipe, since the confining action of the pipe walls to the flow is less pronounced, while the large Taylor bubbles occupy almost the entire cross section in case of the small pipe. Furthermore, the bubbles show much more deformations in the large pipe. Shapes of such large bubbles were characterised in three dimensions for the first time. They can rather be complicated and far from the shape of ideal Taylor bubbles. Also the small bubble fraction tends to bigger sizes in the large pipe

  20. Adapting IMRT delivery fraction-by-fraction to cater for variable intrafraction motion

    International Nuclear Information System (INIS)

    Webb, S

    2008-01-01

    This paper presents a technique for coping with variable intrafraction organ motion when delivering intensity-modulated radiation therapy (IMRT). The strategy is an adaptive delivery in which the fluence delivered up to a particular fraction is subtracted from the required total-course planned fluence to create an adapted residual fluence for the next fraction. This requires that the fluence already delivered can be computed, knowing the intrafraction motion during each fraction. If the adaptation is unconstrained, as would be required for perfect delivery of the planned fluence, then the individual fractional fluences would become unphysical, with both negative components and spikes. Hence it is argued that constraints must be applied; first, positivity constraints and second, constraints to limit fluence spikes. Additionally, it is shown to be helpful to constrain other quantities which are explained. The power of the strategy is that it adapts to the (potentially variable) moving geometry during each fraction. It is not a perfect delivery but it is always better than making no adaptation. The fractionated nature of radiation therapy is thus exploited to advantage. The fluence adaptation method does not require re-planning at each fraction but this imposes limitations which are stated. The fuller theory of dose adaptation is also developed for intrafraction motion. The method is complementary to other adaptive strategies recently discussed with respect to interfraction motion

  1. Two-phase flow structure in large diameter pipes

    International Nuclear Information System (INIS)

    Smith, T.R.; Schlegel, J.P.; Hibiki, T.; Ishii, M.

    2012-01-01

    Highlights: ► Local profiles of various quantities measured in large diameter pipe. ► Database for interfacial area in large pipes extended to churn-turbulent flow. ► Flow regime map confirms previous models for flow regime transitions. ► Data will be useful in developing interfacial area transport models for large pipes. - Abstract: Flow in large pipes is important in a wide variety of applications. In the nuclear industry in particular, understanding of flow in large diameter pipes is essential in predicting the behavior of reactor systems. This is especially true of natural circulation Boiling Water Reactor (BWR) designs, where a large-diameter chimney above the core provides the gravity head to drive circulation of the coolant through the reactor. The behavior of such reactors during transients and during normal operation will be predicted using advanced thermal–hydraulics analysis codes utilizing the two-fluid model. Essential to accurate two-fluid model calculations is reliable and accurate computation of the interfacial transfer terms. These interfacial transfer terms can be expressed as the product of one term describing the potential driving the transfer and a second term describing the available surface area for transfer, or interfacial area concentration. Currently, the interfacial area is predicted using flow regime dependent empirical correlations; however the interfacial area concentration is best computed through the use of the one-dimensional interfacial area transport equation (IATE). To facilitate the development of IATE source and sink term models in large-diameter pipes a fundamental understanding of the structure of the two-phase flow is essential. This understanding is improved through measurement of the local void fraction, interfacial area concentration and gas velocity profiles in pipes with diameters of 0.102 m and 0.152 m under a wide variety of flow conditions. Additionally, flow regime identification has been performed to

  2. Assessment of nanoparticle surface area by measuring unattached fraction of radon progeny

    Energy Technology Data Exchange (ETDEWEB)

    Ruzer, Lev S. [Ernest Orlando Lawrence Berkeley National Laboratory, Indoor Environment Department (United States)], E-mail: LSRuzer@lbl.gov

    2008-05-15

    A number of studies on the exposure of nanometer aerosols have indicated that health effects associated with low-solubility inhaled particles in the range of 1-100 nm may be more appropriately associated with particulate surface area than mass concentration. Such data on correlation between number, surface area and mass concentration are needed for exposure investigations, but the means for measuring aerosol surface area are not readily available. In this paper we propose a method for particle surface area assessment based on a new approach, deposition of the 'unattached fraction of radon progeny' onto nanometer aerosols.The proposed approach represents a synthesis of:(1) Derived direct analytical correlation between the 'unattached fraction' of radon progeny and surface area particle concentration in the range of 1-100 nm particle diameter;(2) Experimental data on correlation between the unattached fraction of radon progeny and particle surface area for particles with diameter in the range of 44 nm-2.1 {mu}m.

  3. Instability of Reference Diameter in the Evaluation of Stenosis After Coronary Angioplasty: Percent Diameter Stenosis Overestimates Dilative Effects Due to Reference Diameter Reduction

    International Nuclear Information System (INIS)

    Hirami, Ryouichi; Iwasaki, Kohichiro; Kusachi, Shozo; Murakami, Takashi; Hina, Kazuyoshi; Matano, Shigeru; Murakami, Masaaki; Kita, Toshimasa; Sakakibara, Noburu; Tsuji, Takao

    2000-01-01

    Purpose: To examine changes in the reference segment luminal diameter after coronary angioplasty.Methods: Sixty-one patients with stable angina pectoris or old myocardial infarction were examined. Coronary angiograms were recorded before coronary angioplasty (pre-angioplasty) and immediately after (post-angioplasty), as well as 3 months after. Artery diameters were measured on cine-film using quantitative coronary angiographic analysis.Results: The diameters of the proximal segment not involved in the balloon inflation and segments in the other artery did not change significantly after angioplasty, but the reference segment diameter significantly decreased (4.7%). More than 10% luminal reduction was observed in seven patients (11%) and more than 5% reduction was observed in 25 patients (41%). More than 5% underestimation of the stenosis was observed in 22 patients (36%) when the post-angioplasty reference diameter was used as the reference diameter, compared with when the pre-angioplasty measurement was used and more than 10% underestimation was observed in five patients (8%).Conclusion: This study indicated that evaluation by percent diameter stenosis, with the reference diameter from immediately after angioplasty, overestimates the dilative effects of coronary angioplasty, and that it is thus better to evaluate the efficacy of angioplasty using the absolute diameter in addition to percent luminal stenosis

  4. Optimization of laser-induced breakdown spectroscopy for coal powder analysis with different particle flow diameters

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Shunchun, E-mail: epscyao@scut.edu.cn [School of Electric Power, South China University of Technology, Guangzhou, Guangdong 510640 (China); State Key Laboratory of Pulsed Power Laser Technology, Electronic Engineering Institute, Hefei 230037 (China); Xu, Jialong; Dong, Xuan; Zhang, Bo; Zheng, Jianping [School of Electric Power, South China University of Technology, Guangzhou, Guangdong 510640 (China); Lu, Jidong, E-mail: jdlu@scut.edu.cn [School of Electric Power, South China University of Technology, Guangzhou, Guangdong 510640 (China)

    2015-08-01

    The on-line measurement of coal is extremely useful for emission control and combustion process optimization in coal-fired plant. Laser-induced breakdown spectroscopy was employed to directly analyze coal particle flow. A set of tapered tubes were proposed for beam-focusing the coal particle flow to different diameters. For optimizing the measurement of coal particle flow, the characteristics of laser-induced plasma, including optical breakdown, the relative standard deviation of repeated measurement, partial breakdown spectra ratio and line intensity, were carefully analyzed. The comparison of the plasma characteristics among coal particle flow with different diameters showed that air breakdown and the random change in plasma position relative to the collection optics could significantly influence on the line intensity and the reproducibility of measurement. It is demonstrated that the tapered tube with a diameter of 5.5 mm was particularly useful to enrich the coal particles in laser focus spot as well as to reduce the influence of air breakdown and random changes of plasma in the experiment. - Highlights: • Tapered tube was designed for beam-focusing the coal particle flow as well as enriching the particles in laser focus spot. • The characteristics of laser-induced plasma of coal particle flow were investigated carefully. • An appropriate diameter of coal particle flow was proven to benefit for improving the performance of LIBS measurement.

  5. Effect of grinding intensity and pelleting of the diet on indoor particulate matter concentrations and growth performance of weanling pigs.

    Science.gov (United States)

    Ulens, T; Demeyer, P; Ampe, B; Van Langenhove, H; Millet, S

    2015-02-01

    This study evaluated the effect of feed form and grinding intensity of the pig diet and the interaction between both on the particulate matter (PM) concentrations inside a pig nursery and the growth performances of weanling pigs. Four diets were compared: finely ground meal, coarsely ground meal, finely ground pellets, and coarsely ground pellets. Four weaning rounds with 144 pigs per weaning round, divided over 4 identical compartments, were monitored. Within each weaning round, each compartment was randomly assigned to 1 of 4 treatments. A hammer mill with a screen of 1.5 or 6 mm was used to grind the ingredients of the finely ground and coarsely ground feeds, respectively. Indoor concentrations of the following PM fractions were measured: PM that passes through a size-selective inlet with a 50 % efficiency cutoff at 10 (PM10) , 2.5 (PM2.5), or 1 (PM1) μm aerodynamic diameter, respectively (USEPA, 2004). Feeding pelleted diets instead of meal diets gave rise to higher PM10 (P Grinding intensity had an effect only on PM10 (P grinding intensity was found for any of the PM fractions. Interactions (P grinding intensity on ADFI and ADG were found. Grinding intensity had an effect only on the meal diets with higher ADFI for the coarsely ground meal. Pigs fed the finely ground meal had a lower (P grinding intensity. Pelleting the feed gave rise to a higher G:F. In conclusion, a contradiction between environmental concerns and performance results was found. Feeding pelleted diets to the piglets improved growth performance but also increased indoor PM concentrations.

  6. Diameter-dependent photoluminescence properties of strong phase-separated dual-wavelength InGaN/GaN nanopillar LEDs

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qiang, E-mail: qwang365@163.com [School of Science, Qilu University of Technology, Jinan, 250353 (China); School of Microelectronics, Shandong University, Jinan, 250100 (China); Ji, Ziwu, E-mail: jiziwu@sdu.edu.cn [School of Microelectronics, Shandong University, Jinan, 250100 (China); Zhou, Yufan; Wang, Xuelin [School of Physics, Shandong University, Jinan, 250100 (China); Liu, Baoli [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing, 100190 (China); Xu, Xiangang [Key Laboratory of Functional Crystal Materials and Device (Ministry of Education), Shandong University, Jinan, 250100 (China); Gao, Xingguo; Leng, Jiancai [School of Science, Qilu University of Technology, Jinan, 250353 (China)

    2017-07-15

    Highlights: • Nanopillar LED with smaller diameter shows a larger strain relaxation in the MQWs. • Nanopillar induced blue shift of green peak is smaller than that of blue peak. • Nanopillar induced blue shift of green/blue peak at 300 K is smaller than at 4 K. • PL intensity decreases with reducing nanopillar diameter with same pillar density. - Abstract: In this paper, strong phase-separated blue/green dual-wavelength InGaN/GaN nanopillar (NP) light emitting diodes (LEDs) with the same NP density and various NP diameters were fabricated using focused ion beam etching. Micro-Raman spectroscopy was used to show the effect of NP diameter on the strain relaxation in the multi-quantum-wells (MQWs). The effect of NP diameter on optical behaviors of the strong phase-separated dual-wavelength InGaN/GaN NP LEDs was investigated for the first time by using micro-photoluminescence (PL) spectroscopy. The blue shifts of PL peak energies of the NP LEDs showed that the NP LED with a smaller diameter exhibited a larger strain relaxation in the MQWs, as confirmed by micro-Raman results. And the blue shift of green emission was smaller than that of blue emission. The total integrated PL intensities from the NP arrays were enhanced compared to the as-grown sample due to the increased recombination rate and light extraction efficiency. The enhancement factor decreased with decreasing the NP diameter in our experiments, which indicated that the loss of active volume was gradually dominant for the luminous efficiency of NP LEDs compared to the increased recombination rate and light extraction efficiency.

  7. Acute hydrodynamic damage induced by SPLITT fractionation and centrifugation in red blood cells.

    Science.gov (United States)

    Urbina, Adriana; Godoy-Silva, Ruben; Hoyos, Mauricio; Camacho, Marcela

    2016-05-01

    Though blood bank processing traditionally employs centrifugation, new separation techniques may be appealing for large scale processes. Split-flow fractionation (SPLITT) is a family of techniques that separates in absence of labelling and uses very low flow rates and force fields, and is therefore expected to minimize cell damage. However, the hydrodynamic stress and possible consequent damaging effects of SPLITT fractionation have not been yet examined. The aim of this study was to investigate the hydrodynamic damage of SPLITT fractionation to human red blood cells, and to compare these effects with those induced by centrifugation. Peripheral whole blood samples were collected from healthy volunteers. Samples were diluted in a buffered saline solution, and were exposed to SPLITT fractionation (flow rates 1-10 ml/min) or centrifugation (100-1500 g) for 10 min. Cell viability, shape, diameter, mean corpuscular hemoglobin, and membrane potential were measured. Under the operating conditions employed, both SPLITT and centrifugation maintained cell viability above 98%, but resulted in significant sublethal damage, including echinocyte formation, decreased cell diameter, decreased mean corpuscular hemoglobin, and membrane hyperpolarization which was inhibited by EGTA. Wall shear stress and maximum energy dissipation rate showed significant correlation with lethal and sublethal damage. Our data do not support the assumption that SPLITT fractionation induces very low shear stress and is innocuous to cell function. Some changes in SPLITT channel design are suggested to minimize cell damage. Measurement of membrane potential and cell diameter could provide a new, reliable and convenient basis for evaluation of hydrodynamic effects on different cell models, allowing identification of optimal operating conditions on different scales. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Three-dimensional fluorescence analysis of chernozem humic acids and their electrophoretic fractions

    Science.gov (United States)

    Trubetskoi, O. A.; Trubetskaya, O. E.

    2017-09-01

    Polyacrylamide gel electrophoresis in combination with size-exclusion chromatography (SEC-PAGE) has been used to obtain stable electrophoretic fractions of different molecular size (MS) from chernozem humic acids (HAs). Three-dimensional fluorescence charts of chernozem HAs and their fractions have been obtained for the first time, and all fluorescence excitation-emission maxima have been identified in the excitation wavelength range of 250-500 nm. It has been found that fractionation by the SEC-PAGE method results in a nonuniform distribution of protein- and humin-like fluorescence of the original HA preparation among the electrophoretic fractions. The electrophoretic fractions of the highest and medium MSs have only the main protein-like fluorescence maximum and traces of humin-like fluorescence. In the electrophoretic fraction of the lowest MS, the intensity of protein-like fluorescence is low, but the major part of humin-like fluorescence is localized there. Relationships between the intensity of protein-like fluorescence and the weight distribution of amino acids have been revealed, as well as between the degree of aromaticity and the intensity of humin-like fluorescence in electrophoretic fractions of different MSs. The obtained relationships can be useful in the interpretation of the spatial structural organization and ecological functions of soil HAs.

  9. Role of the outer-edge flame on flame extinction in nitrogen-diluted non-premixed counterflow flames with finite burner diameters

    KAUST Repository

    Chung, Yong Ho

    2013-03-01

    This study of nitrogen-diluted non-premixed counterflow flames with finite burner diameters investigates the important role of the outer-edge flame on flame extinction through experimental and numerical analyses. It explores flame stability diagrams mapping the flame extinction response of nitrogen-diluted non-premixed counterflow flames to varying global strain rates in terms of burner diameter, burner gap, and velocity ratio. A critical nitrogen mole fraction exists beyond which the flame cannot be sustained; the critical nitrogen mole fraction versus global strain rate curves have C-shapes for various burner diameters, burner gaps, and velocity ratios. At sufficiently high strain-rate flames, these curves collapse into one curve; therefore, the flames follow the one-dimensional flame response of a typical diffusion flame. Low strain-rate flames are significantly affected by radial conductive heat loss, and therefore flame length. Three flame extinction modes are identified: flame extinction through shrinkage of the outer-edge flame with or without oscillations at the outer-edge flame prior to the extinction, and flame extinction through a flame hole at the flame center. The extinction modes are significantly affected by the behavior of the outer-edge flame. Detailed explanations are provided based on the measured flame-surface temperature and numerical evaluation of the fractional contribution of each term in the energy equation. Radial conductive heat loss at the flame edge to ambience is the main mechanism of extinction through shrinkage of the outer-edge flame in low strain-rate flames. Reduction of the burner diameter can extend the flame extinction mode by shrinking the outer-edge flame in higher strain-rate flames. © 2012 Elsevier Ltd. All rights reserved.

  10. Fractional Fourier transform for confluent hypergeometric beams

    International Nuclear Information System (INIS)

    Tang, Bin; Jiang, Chun; Zhu, Haibin

    2012-01-01

    Based on the definition of the fractional Fourier transform (FRFT) in the cylindrical coordinate system, the propagation properties of a new family of paraxial laser beams named confluent hypergeometric (HyG) beams, of which intensity profile is similar to that for the Bessel modes, passing through FRFT optical systems have been studied in detail by some typical numerical examples. The results indicate that the normalized intensity distribution of a HyG beam in the FRFT plane is closely related to not only the fractional order p but also the beam parameters m,n, and focal length f. -- Highlights: ► We study the propagation of a HyG beam through FRFT optical systems. ► The intensity of the beam in the FRFT plane is closely related to some parameters. ► We can control the properties of HyG beams by properly choosing the parameters.

  11. Diameter optimization of VLS-synthesized ZnO nanowires, using statistical design of experiment

    International Nuclear Information System (INIS)

    Shafiei, Sepideh; Nourbakhsh, Amirhasan; Ganjipour, Bahram; Zahedifar, Mostafa; Vakili-Nezhaad, Gholamreza

    2007-01-01

    The possibility of diameter optimization of ZnO nanowires by using statistical design of experiment (DoE) is investigated. In this study, nanowires were synthesized using a vapor-liquid-solid (VLS) growth method in a horizontal reactor. The effects of six synthesis parameters (synthesis time, synthesis temperature, thickness of gold layer, distance between ZnO holder and substrate, mass of ZnO and Ar flow rate) on the average diameter of a ZnO nanowire were examined using the fractional factorial design (FFD) coupled with response surface methodology (RSM). Using a 2 III 6-3 FFD, the main effects of the thickness of the gold layer, synthesis temperature and synthesis time were concluded to be the key factors influencing the diameter. Then Box-Behnken design (BBD) was exploited to create a response surface from the main factors. The total number of required runs for the DoE process is 25, 8 runs for FFD parameter screening and 17 runs for the response surface obtained by BBD. Three extra runs are done to confirm the predicted results

  12. Clinical implications of portal hemodynamics after small-diameter portacaval H graft

    International Nuclear Information System (INIS)

    Sarfeh, I.J.; Rypins, E.B.; Fardi, M.; Conroy, R.M.; Mason, G.R.; Lyons, K.P.

    1984-01-01

    To assess the role of portal hemodynamics in the development of postshunt encephalopathy, we studied 19 patients after small-diameter portacaval H grafting (SD-PCHG). We used contrast studies as well as technetium-labeled macroaggregated albumin injected into the portal vein to assess direction of portal flow. We then quantitated the mesenteric fraction of flow perfusing the liver by injecting macroaggregated albumin into a peripheral mesenteric vein tributary. We found that none of seven patients with prograde flow by both scintigraphy and angiography developed postoperative encephalopathy, but the incidence was 58% in the remaining patients (p . 0.02). The fraction of mesenteric flow perfusing the liver after SD-PCHG was 12% +/- 4%, but this did not significantly correlate with encephalopathy rates. We conclude that after SD-PCHG, prograde portal flow minimizes encephalopathy rates. Although encephalopathy occurs in patients with predominantly reversed flow, a subgroup of patients with reversed flow remain without symptoms. The absolute fraction of mesenteric flow perfusing the liver has less influence on encephalopathy rates than has direction of portal flow. This study identifies a complex relationship between portal hemodynamics and encephalopathy

  13. Sugar maple height-diameter and age-diameter relationships in an uneven-aged northern hardwood stand

    Science.gov (United States)

    Laura S. Kenefic; R.D. Nyland

    1999-01-01

    Sugar maple (Acer saccharum Marsh.) height-diameter and age-diameter relationships are explored in a balanced uneven-aged northern hardwood stand in central New York. Results show that although both height and age vary considerably with diameter, these relationships can be described by statistically valid equations. The age-diameter relationship...

  14. Local progression and pseudo progression after single fraction or fractionated stereotactic radiotherapy for large brain metastases. A single centre study

    Energy Technology Data Exchange (ETDEWEB)

    Wiggenraad, R.; Verbeek-de Kanter, A.; Mast, M. [Radiotherapy Centre West, The Hague (Netherlands); Molenaar, R. [Diaconessenhuis, Leiden (Netherlands). Dept. of Neurology; Lycklama a Nijeholt, G. [Medical Centre Haagladen, The Hague (Netherlands). Dept. of Radiology; Vecht, C. [Medical Centre Haagladen, The Hague (Netherlands). Dept. of Neurology; Struikmans, H. [Radiotherapy Centre West, The Hague (Netherlands); Leiden Univ. Medical Centre (Netherlands). Dept. of Radiotherapy; Kal, H.B.

    2012-08-15

    Purpose: The 1-year local control rates after single-fraction stereotactic radiotherapy (SRT) for brain metastases > 3 cm diameter are less than 70%, but with fractionated SRT (FSRT) higher local control rates have been reported. The purpose of this study was to compare our treatment results with SRT and FSRT for large brain metastases. Materials and methods: In two consecutive periods, 41 patients with 46 brain metastases received SRT with 1 fraction of 15 Gy, while 51 patients with 65 brain metastases received FSRT with 3 fractions of 8 Gy. We included patients with brain metastases with a planning target volume of > 13 cm{sup 3} or metastases in the brainstem. Results: The minimum follow-up of patients still alive was 22 months. Comparing 1 fraction of 15 Gy with 3 fractions of 8 Gy, the 1-year rates of freedom from any local progression (54% and 61%, p = 0.93) and pseudo progression (85% and 75%, p = 0.25) were not significantly different. Overall survival rates were also not different. Conclusion: The 1-year local progression and pseudo progression rates after 1 fraction of 15 Gy or 3 fractions of 8 Gy for large brain metastases and metastases in the brainstem are similar. For better local control rates, FSRT schemes with a higher biological equivalent dose may be necessary. (orig.)

  15. Local progression and pseudo progression after single fraction or fractionated stereotactic radiotherapy for large brain metastases. A single centre study

    International Nuclear Information System (INIS)

    Wiggenraad, R.; Verbeek-de Kanter, A.; Mast, M.; Molenaar, R.; Lycklama a Nijeholt, G.; Vecht, C.; Struikmans, H.; Leiden Univ. Medical Centre; Kal, H.B.

    2012-01-01

    Purpose: The 1-year local control rates after single-fraction stereotactic radiotherapy (SRT) for brain metastases > 3 cm diameter are less than 70%, but with fractionated SRT (FSRT) higher local control rates have been reported. The purpose of this study was to compare our treatment results with SRT and FSRT for large brain metastases. Materials and methods: In two consecutive periods, 41 patients with 46 brain metastases received SRT with 1 fraction of 15 Gy, while 51 patients with 65 brain metastases received FSRT with 3 fractions of 8 Gy. We included patients with brain metastases with a planning target volume of > 13 cm 3 or metastases in the brainstem. Results: The minimum follow-up of patients still alive was 22 months. Comparing 1 fraction of 15 Gy with 3 fractions of 8 Gy, the 1-year rates of freedom from any local progression (54% and 61%, p = 0.93) and pseudo progression (85% and 75%, p = 0.25) were not significantly different. Overall survival rates were also not different. Conclusion: The 1-year local progression and pseudo progression rates after 1 fraction of 15 Gy or 3 fractions of 8 Gy for large brain metastases and metastases in the brainstem are similar. For better local control rates, FSRT schemes with a higher biological equivalent dose may be necessary. (orig.)

  16. Nonuniform Internal Structure of Fibrin Fibers: Protein Density and Bond Density Strongly Decrease with Increasing Diameter

    Directory of Open Access Journals (Sweden)

    Wei Li

    2017-01-01

    Full Text Available The major structural component of a blood clot is a meshwork of fibrin fibers. It has long been thought that the internal structure of fibrin fibers is homogeneous; that is, the protein density and the bond density between protofibrils are uniform and do not depend on fiber diameter. We performed experiments to investigate the internal structure of fibrin fibers. We formed fibrin fibers with fluorescently labeled fibrinogen and determined the light intensity of a fiber, I, as a function of fiber diameter, D. The intensity and, thus, the total number of fibrin molecules in a cross-section scaled as D1.4. This means that the protein density (fibrin per cross-sectional area, ρp, is not homogeneous but instead strongly decreases with fiber diameter as D-0.6. Thinner fibers are denser than thicker fibers. We also determined Young’s modulus, Y, as a function of fiber diameter. Y decreased strongly with increasing D; Y scaled as D-1.5. This implies that the bond density, ρb, also scales as D-1.5. Thinner fibers are stiffer than thicker fibers. Our data suggest that fibrin fibers have a dense, well-connected core and a sparse, loosely connected periphery. In contrast, electrospun fibrinogen fibers, used as a control, have a homogeneous cross-section.

  17. Separation of carbon nanotubes into chirally enriched fractions

    Science.gov (United States)

    Doorn, Stephen K [Los Alamos, NM; Niyogi, Sandip [Los Alamos, NM

    2012-04-10

    A mixture of single-walled carbon nanotubes ("SWNTs") is separated into fractions of enriched chirality by preparing an aqueous suspension of a mixture of SWNTs and a surfactant, injecting a portion of the suspension on a column of separation medium having a density gradient, and centrifuging the column. In some embodiments, salt is added prior to centrifugation. In other embodiments, the centrifugation is performed at a temperature below room temperature. Fractions separate as colored bands in the column. The diameter of the separated SWNTs decreases with increasing density along the gradient of the column. The colored bands can be withdrawn separately from the column.

  18. Dry fractionation for sustainable production of functional legume protein concentrates

    NARCIS (Netherlands)

    Schutyser, M.A.I.; Pelgrom, P.J.M.; Goot, van der A.J.; Boom, R.M.

    2015-01-01

    Plant proteins gain increasing interest as part of a sustainable diet. Because plant materials not only contain protein, they are generally isolated via an energy intensive wet fractionation. This review discusses dry fractionation as an alternative and more sustainable route for producing

  19. Comparison of long-term survival and toxicity of simultaneous integrated boost vs conventional fractionation with intensity-modulated radiotherapy for the treatment of nasopharyngeal carcinoma

    Directory of Open Access Journals (Sweden)

    Tao HM

    2016-03-01

    Full Text Available Hengmin Tao,1,2 Yumei Wei,1 Wei Huang,1 Xiujuan Gai,1,2 Baosheng Li11Department of 6th Radiation Oncology, Shandong Cancer Hospital and Institute, 2School of Medicine and Life Sciences, Jinan University-Shandong Academy of Medical Sciences, Jinan, People’s Republic of ChinaAim: In recent years, the intensity-modulated radiotherapy with simultaneous integrated boost (IMRT-SIB and intensity-modulated radiotherapy with conventional fractionation (IMRT-CF have been involved in the treatment of nasopharyngeal carcinoma (NPC. However, the potential clinical effects and toxicities are still controversial.Methods: Here, 107 patients with biopsy-proven locally advanced NPC between March 2004 and January 2011 were enrolled in the retrospective study. Among them, 54 patients received IMRT-SIB, and 53 patients received IMRT-CF. Subsequently, overall survival (OS, 5-year progression-free survival (PFS, 5-year locoregional recurrence-free survival (LRFS, and relevant toxicities were analyzed.Results: In the present study, all patients completed the treatment, and the overall median follow-up time was 80 months (range: 8–126 months. The 5-year OS analysis revealed no significant difference between the IMRT-SIB and IMRT-CF groups (80.9% vs 80.5%, P=0.568. In addition, there were also no significant between-group differences in 5-year PFS (73.3% vs 74.4%, P=0.773 and 5-year LRFS (88.1% vs 90.8%, P=0.903. Notably, the dose to critical organs (spinal cord, brainstem, and parotid gland in patients treated by IMRT-CF was significantly lower than that in patients treated by IMRT-SIB (all P<0.05.Conclusion: Both IMRT-SIB and IMRT-CF techniques are effective in treating locally advanced NPC, with similar OS, PFS, and LRFS. However, IMRT-CF has more advantages than IMRT-SIB in protecting spinal cord, brainstem, and parotid gland from acute and late toxicities, such as xerostomia. Further prospective study is warranted to confirm our findings.Keywords: intensity

  20. Dependence of light scattering profile in tissue on blood vessel diameter and distribution: a computer simulation study.

    Science.gov (United States)

    Duadi, Hamootal; Fixler, Dror; Popovtzer, Rachela

    2013-11-01

    Most methods for measuring light-tissue interactions focus on the volume reflectance while very few measure the transmission. We investigate both diffusion reflection and diffuse transmission at all exit angles to receive the full scattering profile. We also investigate the influence of blood vessel diameter on the scattering profile of a circular tissue. The photon propagation path at a wavelength of 850 nm is calculated from the absorption and scattering constants via Monte Carlo simulation. Several simulations are performed where a different vessel diameter and location were chosen but the blood volume was kept constant. The fraction of photons exiting the tissue at several central angles is presented for each vessel diameter. The main result is that there is a central angle that below which the photon transmission decreased for lower vessel diameters while above this angle the opposite occurred. We find this central angle to be 135 deg for a two-dimensional 10-mm diameter circular tissue cross-section containing blood vessels. These findings can be useful for monitoring blood perfusion and oxygen delivery in the ear lobe and pinched tissues. © 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)

  1. Fabricated nano-fiber diameter as liquid concentration sensors

    Science.gov (United States)

    Chyad, Radhi M.; Mat Jafri, Mohd Zubir; Ibrahim, Kamarulazizi

    Nanofiber is characterized by thin, long, and very soft silica. Taper fibers are made using an easy and low cost chemical method. Etching is conducted with a HF solution to remove cladding and then a low molarity HF solution to reduce the fiber core diameter. One approach to on-line monitoring of the etching process uses spectrophotometer with a white light source. In the aforementioned technique, this method aims to determine the diameter of the reduced core and show the evolution of the two different processes from the nanofiber regime to the fixed regime in which the mode was remote from the surrounding evanescent field, intensity can propagate outside the segment fiber when the core diameter is less than 500 nm. Manufacturing technologies of nano-fiber sensors offer a number of approved properties of optical fiber sensors utilized in various sensory applications. The nano-fiber sensor is utilized to sense the difference in the concentration of D-glucose in double-distilled deionized water and to measure the refractive index (RI) of a sugar solution. Our proposed method exhibited satisfactory capability based on bimolecular interactions in the biological system. The response of the nano-fiber sensors indicates a different kind of interaction among various groups of AAs. These results can be interpreted in terms of solute-solute and solute-solvent interactions and the structure making or breaking ability of solutes in the given solution. This study utilized spectra photonics to measure the transmission of light through different concentrations of sugar solution, employing cell cumber and nano-optical fibers as sensors.

  2. Diameter-speed relation of sprite streamers

    International Nuclear Information System (INIS)

    Kanmae, T; Stenbaek-Nielsen, H C; McHarg, M G; Haaland, R K

    2012-01-01

    Propagation and splitting of sprite streamers has been observed at high temporal and spatial resolution using two intensified high-speed CMOS cameras recording at 10 000 and 16 000 frames per second. Concurrent video recordings from a remote site provided data for triangulation allowing us to determine accurate altitude scales for the sprites. Diameters and speeds of the sprite streamers were measured from the high-speed images, and the diameters were scaled to the reduced diameters based on the triangulated locations. The sprite streamers with larger reduced diameter move faster than those with smaller diameter; the relation between the reduced diameter and speed is roughly linear. The reduced diameters at ≈65-70 km altitude are larger than streamer diameters measured at ground pressure in laboratory discharges indicating a deviation from the similarity law possibly due to the effects of the photoionization and an expansion of the streamer head along its propagation over a long distance. The reduced diameter and speed of the sprite streamers agree well with the diameter-velocity relation proposed by Naidis (2009 Phys. Rev. E 79 057401), and the peak electric field of the sprite streamers is estimated to be approximately 3-5 times the breakdown threshold field. (paper)

  3. Stress concentration factor and stress intensity factor on hard metals in connection with the wear characteristics

    International Nuclear Information System (INIS)

    Dawihl, W.; Altmeyer, G.

    1977-01-01

    Description of a method to determine stress intensity factors on hard metals by lapping in notches of different diameter. Dependence of the values of the stress intensity factors on the size of the notch base diameter. For tungsten carbide hard metals with 6% Co, determination of a final value of 250 Nmm -3 / 2 . Characterisation of the stress intensity factor governed by the surface roughness which is decisive for the assessment of the wear-resistant behaviour. (orig.) [de

  4. Improvement of Estimation method for two-phase flow in a large-diameter pipe. Pt. 4. Effect of the inlet boundary condition of the upward flow section on flow characteristics

    International Nuclear Information System (INIS)

    Yoneda, Kimitoshi; Okawa, Tomio; Zhou, Shirong

    1999-01-01

    In nuclear power plants, many large-diameter pipes are subject to gas-liquid two-phase flow. For rational design and performance estimation, the flow in the pipes should be predicted accurately. With the correlation used at present, however, the flow analysis can not reach desirable precision. This is partly due to the lack of understanding of the two-phase flow characteristics in large-diameter pipes. Therefore, steam-water two-phase flow in a vertical pipe (155 mm i.d.) was investigated empirically. Lateral distribution data of phase volume fraction, gas velocity and bubble diameter were obtained. The effects of the inlet boundary condition were also observed. The drift velocity in the developing region was considerably affected by the inlet boundary condition. By deriving the correlation of mean bubble diameter as a function of void fraction and pressure, the empirical data was predicted with high accuracy compared with the existing correlation used in best-estimate codes of nuclear reactor safety analysis. (author)

  5. VizieR Online Data Catalog: JMDC : JMMC Measured Stellar Diameters Catalogue (Duvert, 2016)

    Science.gov (United States)

    Duvert, G.

    2016-11-01

    Several star diameter compilations exist that contain a fair amount of stellar angular diameter measurements. The CADARS (2011, Cat. II/224) has entries for 6888 stars and claims completeness up to 1997. CHARM2 (2005, Cat. J/A+A/431/773) lists 8231 measurements of 3243 stars, up to 2005. However all these catalogs mix results from very direct methods, such as intensity interferometry, with indirect methods, or spectrophotometric estimates of various kind (always including some model of the star), or linear diameters from eclipsing binaries (1600 entries in CADARS), which need some modelling of the two stars, as well as a good estimate of the distance to be converted into an angular diameter. In contrary, the present catalogue, called JMDC (for JMMC Measured stellar Diameters Catalog) is focussed on direct methods only, and selects only one value of the uniform-disk diameter (UDD) and limb-darkened diameter (LDD) for each historical measurement. It should be regularly updated via a specialized submission tool that will be made available on the JMMC website (www.jmmc.fr). The current version gathers 1478 measurements that have been published since the first experiments by Michelson. Prior to 1997, our bibliography relies only on the reference list of CADARS, carefully reviewed. After this date we used NASA's ADS hosted at CDS. We retained only the measurements obtained from visible/IR interferometry, intensity interferometry and lunar occultation in the database. We always retrieved the values in the original text and used SIMBAD to properly and uniquely identify the stars. The three techniques retained share the same method of converting the measurements (squared visibilities for optical interferometry, correlation of photon-counts for intensity interferometry, fast photometry for lunar occultations) into an angular diameter: fitting a geometrical function into the values, in many cases a uniform disk, which provides a uniform disk diameter (UDD) value. This UDD is

  6. SU-F-T-196: Hypo-Fractionation with Intensity Modulated Proton Therapy for Unilateral Metallic Prosthesis Prostate Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Rana, S; Park, S [McLaren Proton Therapy Center, Karmanos Cancer Institute at McLaren-Flint, Flint, MI (United States); Zheng, Y [Procure Proton Therapy Center, Oklahoma City, OK (United States); Zhang, Y [University of Cincinnati Medical Center, Liberty Township, OH (United States); Pokharel [21st Century Oncology, Estero, FL (United States); Cheng, C [Vantage Oncology, West Hills, CA (United States)

    2016-06-15

    Purpose: The purpose of this study is to investigate the dosimetric feasibility of hypo-fractionated intensity modulated proton therapy (IMPT) for unilateral metallic prosthesis prostate cancer patients based on proton collaborative group (PCG)-GU002-10 (NCT01230866) protocol criteria. Methods: A total of five unilateral metallic prosthesis prostate cancer cases were included in this retrospective study. For each case, IMPT plans were generated for treatment to be delivered with 7.6 Gy[RBE] per fraction in 5 fractions per week for a total dose of 38 Gy(RBE). Each plan was generated using two anterior-oblique beams and one lateral beam. Treatment plans were optimized with an objective meeting PCG-GU002-10 (NCT01230866) protocol criteria: (i) planning target volume (PTV): D99.5% > 36.1 Gy[RBE], (ii) rectum: V24 < 35%, V33.6 < 10%, (iii) bladder: V39 < 8 cc, and (iv) femoral head: V23 < 1cc. Results: All five cases satisfied PTV D99.5% (average=36.82 Gy[RBE]; range, 36.36–37.13 Gy[RBE]). PTV D95% ranged from 36.66 Gy[RBE] to 38.65 Gy[RBE] and PTV V100 ranged from 95.47% to 97.95%. For the rectum, V24 was less than 35% (average=14.07 Gy[RBE]; range, 6.22–18.42%, whereas V33.6 Gy[RBE] was less than 10% (average=6.83; range, 3.06 – 9.15%). Rectal mean dose ranged from 4.22 Gy[RBE] to 9.97 Gy[RBE]. For the bladder, V39 was found to be less than 8 cc (average=3.69 cc; range, 0.19–7.68 cc). Bladder mean dose ranged from 4.22 Gy[RBE] to 18.83 Gy[RBE]. For the femoral head, V23 was 0 in all five cases. Conclusion: All five unilateral metallic prosthesis prostate cancer IMPT plans generated with one lateral and two anterior-oblique beams satisfied the dosimetric criteria of PCG-GU002-10 (NCT01230866) protocol.

  7. Gas phase fractionation method using porous ceramic membrane

    Science.gov (United States)

    Peterson, Reid A.; Hill, Jr., Charles G.; Anderson, Marc A.

    1996-01-01

    Flaw-free porous ceramic membranes fabricated from metal sols and coated onto a porous support are advantageously used in gas phase fractionation methods. Mean pore diameters of less than 40 .ANG., preferably 5-20 .ANG. and most preferably about 15 .ANG., are permeable at lower pressures than existing membranes. Condensation of gases in small pores and non-Knudsen membrane transport mechanisms are employed to facilitate and increase membrane permeability and permselectivity.

  8. Tree diameter at breast height in relation to stump diameter by species group

    Science.gov (United States)

    Arthur G. Horn; Richard C. Keller

    1957-01-01

    A stump tally is one method of determining the volume of timber previously removed from an area in a logging operation. To estimate volume of standing timber from stumps, foresters must first know the relationship between stump diameters and tree diameters at breast height (d.b.h.).

  9. Determining the void fraction in draught sections of a boiling water cooled reactor

    International Nuclear Information System (INIS)

    Fedulin, V.N.; Barolomej, G.G.; Solodkij, V.A.; Shmelev, V.E.

    1987-01-01

    Consideration is being given to the problem of improving methods for calculation of the void fraction in large channels of cooling system of the boiling water cooled reactor during two-phase unsteady flow. Investigation of the structure of two-phase flow was conducted in draught section of the VK-50 reactor (diameter D=2 m, height H=3). The method for calculation of the void fraction in channels with H/D ratio close to 1 is suggested

  10. Study of pressure drop, void fraction and relative permeabilities of two phase flow through porous media

    International Nuclear Information System (INIS)

    Chu, W.; Dhir, V.K.; Marshall, J.

    1983-01-01

    An experimental investigation of two phase flow through porous layers formed of non-heated glass particles (nominal diameter 1 to 6 mm) has been made. Particulate bed depths of 30 cm and 70 cm were used. The effect of particle size, particle size distribution and bed porosity on void fraction and pressure drop through a particulate bed formed in a cylindrical test section has been investigated. The superficial velocity of liquid (water) is varied from 1.83 to 18.3 mm/s while the superficial velocity of gas (air) is varied from 0 to 68.4 mm/s. These superficial velocities were chosen so that pressure drop and void fraction measurement could be made for the porous layer in fixed and fluidized states. A model based on drift flux approach has been developed for the void fraction. Using the two phase friction pressure drop data, the relative permeabilities of the two phases have been concluded with void fraction. The void fraction and two phase friction pressure gradient in beds composed of mixtures of spherical particles as well as sharps of different nominal sizes have also been examined. It is found that the models for single size particles are also applicable to mixtures of particles if a mean particle diameter for the mixture is defined

  11. Growth response of Lebanon cedar (Cedrus libani) plantations to thinning intensity in Western Turkey.

    Science.gov (United States)

    Carus, Serdar; Catal, Yilmaz

    2010-09-01

    This paper presents the growth response of 25 yr old Lebanon cedar (Cedrus libani A. Rich.) plantation to thinnings of different intensities in Isparta in western Turkey. The thinning intensity was measured by using the residual basal area (%) as parameter. In spring of 2005, three treatments were tested; light, moderate and heavy thinning with respectively 10, 25 and 35% of basal area removed. The statistical design of the experiment was a randomized incomplete block with two blocks and three treatments. Variables such as diameter at breast height (diameter) and height were measured. Growth rate ratios of diameter in moderately thinned and heavily thinned stands were 1.02 and 1.03, respectively. Basal area growth rates in moderately thinned and heavily thinned plots were 0.93 and 1.05, respectively. The largest values for the mean tree were observed with the heaviest thinning treatment. Absolute diameter increment was positively correlated with initial diameter in all plots. Relative diameter growth was negatively correlated with initial diameter. Growth rate interpretations were supported by analysis of variance using Duncan's test of range multiple. The results obtained show significant differences between treatments for tree height growth, for the two inventories carried out (2005, 2008). However diameter basal area and volume were no found between treatments for tree.

  12. Void fraction and velocity measurement of simulated bubble in a rotating disc using high frame rate neutron radiography.

    Science.gov (United States)

    Saito, Y; Mishima, K; Matsubayashi, M

    2004-10-01

    To evaluate measurement error of local void fraction and velocity field in a gas-molten metal two-phase flow by high-frame-rate neutron radiography, experiments using a rotating stainless-steel disc, which has several holes of various diameters and depths simulating gas bubbles, were performed. Measured instantaneous void fraction and velocity field of the simulated bubbles were compared with the calculated values based on the rotating speed, the diameter and the depth of the holes as parameters and the measurement error was evaluated. The rotating speed was varied from 0 to 350 rpm (tangential velocity of the simulated bubbles from 0 to 1.5 m/s). The effect of shutter speed of the imaging system on the measurement error was also investigated. It was revealed from the Lagrangian time-averaged void fraction profile that the measurement error of the instantaneous void fraction depends mainly on the light-decay characteristics of the fluorescent converter. The measurement error of the instantaneous local void fraction of simulated bubbles is estimated to be 20%. In the present imaging system, the light-decay characteristics of the fluorescent converter affect the measurement remarkably, and so should be taken into account in estimating the measurement error of the local void fraction profile.

  13. Void fraction and velocity measurement of simulated bubble in a rotating disc using high frame rate neutron radiography

    International Nuclear Information System (INIS)

    Saito, Y.; Mishima, K.; Matsubayashi, M.

    2004-01-01

    To evaluate measurement error of local void fraction and velocity field in a gas-molten metal two-phase flow by high-frame-rate neutron radiography, experiments using a rotating stainless-steel disc, which has several holes of various diameters and depths simulating gas bubbles, were performed. Measured instantaneous void fraction and velocity field of the simulated bubbles were compared with the calculated values based on the rotating speed, the diameter and the depth of the holes as parameters and the measurement error was evaluated. The rotating speed was varied from 0 to 350 rpm (tangential velocity of the simulated bubbles from 0 to 1.5 m/s). The effect of shutter speed of the imaging system on the measurement error was also investigated. It was revealed from the Lagrangian time-averaged void fraction profile that the measurement error of the instantaneous void fraction depends mainly on the light-decay characteristics of the fluorescent converter. The measurement error of the instantaneous local void fraction of simulated bubbles is estimated to be 20%. In the present imaging system, the light-decay characteristics of the fluorescent converter affect the measurement remarkably, and so should be taken into account in estimating the measurement error of the local void fraction profile

  14. Phase I/II trial of single-fraction high-dose-rate brachytherapy-boosted hypofractionated intensity-modulated radiation therapy for localized adenocarcinoma of the prostate.

    Science.gov (United States)

    Myers, Michael A; Hagan, Michael P; Todor, Dorin; Gilbert, Lynn; Mukhopadhyay, Nitai; Randolf, Jessica; Heimiller, Jeffrey; Anscher, Mitchell S

    2012-01-01

    A Phase I/II protocol was conducted to examine the toxicity and efficacy of the combination of intensity-modulated radiation therapy (IMRT) with a single-fraction high-dose-rate (HDR) brachytherapy implant. From 2001 through 2006, 26 consecutive patients were treated on the trial. The primary objective was to demonstrate a high rate of completion without experiencing a treatment-limiting toxicity. Eligibility was limited to patients with T stage ≤2b, prostate-specific antigen (PSA) ≤20, and Gleason score ≤7. Treatment began with a single HDR fraction of 6Gy to the entire prostate and 9Gy to the peripheral zone, followed by IMRT optimized to deliver in 28 fractions with a normalized total dose of 70Gy. Patients received 50.4Gy to the pelvic lymph node. The prostate dose (IMRT and HDR) resulted in an average biologic equivalent dose >128Gy (α/β=3). Patients whose pretreatment PSA was ≥10ng/mL, Gleason score 7, or stage ≥T2b received short-term androgen ablation. Median followup was 53 months (9-68 months). There were no biochemical failures by either the American Society of Therapeutic Radiology and Oncology or the Phoenix definitions. The median nadir PSA was 0.32ng/mL. All the 26 patients completed the treatment as prescribed. The rate of Grade 3 late genitourinary toxicity was 3.8% consisting of a urethral stricture. There was no other Grade 3 or 4 genitourinary or gastrointestinal toxicities. Single-fraction HDR-boosted IMRT is a safe effective method of dose escalation for localized prostate cancer. Copyright © 2012 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  15. The Relationship amongst Intervertebral Disc Vertical Diameter, Lateral Foramen Diameter and Nerve Root Impingement in Lumbar Vertebra

    Directory of Open Access Journals (Sweden)

    Yusof MI

    2018-03-01

    Full Text Available Introduction: The vertical diameter of the foramen is dependent upon the vertical diameter of the corresponding intervertebral disc. A decrease in disc vertical diameter has direct anatomic consequences to the foraminal diameter and area available for the nerve root passing through it. This study is to establish the relationship amongst the intervertebral disc vertical diameter, lateral foramen diameters and nerve root compression in the lumbar vertebra. Materials and Methods: Measurements of the study parameters were performed using sagittal MRI images. The parameters studied were: intervertebral disc vertical diameter (DVD, foraminal vertical diameter (FVD, foraminal transverse diameter (FTD and nerve root diameter (NRD of both sides. The relationship between the measured parameters were then analyzed. Results: A total of 62 MRI images were available for this study. Statistical analysis showed moderate to strong correlation between DVD and FVD at all the lumbar levels except at left L23 and L5S1 and right L3L4 and L4L5. Correlation between DVD and FTD were not significant at all lumbar levels. Regression analysis showed that a decrease of 1mm of DVD was associated with 1.3, 1.7, 3.3, 3.3 and 1.3mm reduction of FVD at L1L2, L2L3, L3L4, L4L5 and L5S1 respectively. Conclusion: Reduction of DVD was associated with reduction of FVD. However, FVD was relatively wide for the nerve root even with complete loss of DVD. FTD was much narrower than the FVD making it more likely to cause nerve root compression at the exit foramina. These anatomical details should be given consideration in treating patients with lateral canal stenosis.

  16. Fractionating power and outlet stream polydispersity in asymmetrical flow field-flow fractionation. Part I: isocratic operation.

    Science.gov (United States)

    Williams, P Stephen

    2016-05-01

    Asymmetrical flow field-flow fractionation (As-FlFFF) has become the most commonly used of the field-flow fractionation techniques. However, because of the interdependence of the channel flow and the cross flow through the accumulation wall, it is the most difficult of the techniques to optimize, particularly for programmed cross flow operation. For the analysis of polydisperse samples, the optimization should ideally be guided by the predicted fractionating power. Many experimentalists, however, neglect fractionating power and rely on light scattering detection simply to confirm apparent selectivity across the breadth of the eluted peak. The size information returned by the light scattering software is assumed to dispense with any reliance on theory to predict retention, and any departure of theoretical predictions from experimental observations is therefore considered of no importance. Separation depends on efficiency as well as selectivity, however, and efficiency can be a strong function of retention. The fractionation of a polydisperse sample by field-flow fractionation never provides a perfectly separated series of monodisperse fractions at the channel outlet. The outlet stream has some residual polydispersity, and it will be shown in this manuscript that the residual polydispersity is inversely related to the fractionating power. Due to the strong dependence of light scattering intensity and its angular distribution on the size of the scattering species, the outlet polydispersity must be minimized if reliable size data are to be obtained from the light scattering detector signal. It is shown that light scattering detection should be used with careful control of fractionating power to obtain optimized analysis of polydisperse samples. Part I is concerned with isocratic operation of As-FlFFF, and part II with programmed operation.

  17. Effects of Diameter on Initial Stiffness of P-Y Curves for Large-Diameter Piles in Sand

    DEFF Research Database (Denmark)

    Sørensen, Søren Peder Hyldal; Ibsen, Lars Bo; Augustesen, Anders Hust

    2010-01-01

    is developed for slender piles with diameters up to approximately 2.0 m. Hence, the method is not validated for piles with diameters of 4–6 m. The aim of the paper is to extend the p-y curve method to large-diameter non-slender piles in sand by considering the effects of the pile diameter on the soil-pile...... interaction. Hence, a modified expression for the p-y curves for statically loaded piles in sand is proposed in which the initial slope of the p-y curves depends on the depth below the soil surface, the pile diameter and the internal angle of friction. The evaluation is based on three-dimensional numerical...... analyses by means of the commercial program FLAC3D incorporating a Mohr-Coulomb failure criterion. The numerical model is validated with laboratory tests in a pressure tank at Aalborg University....

  18. Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers

    International Nuclear Information System (INIS)

    Mohan, Radhe; Wu Qiuwen; Manning, Matthew; Schmidt-Ullrich, Rupert

    2000-01-01

    Purpose: The dose distributions of intensity-modulated radiotherapy (IMRT) treatment plans can be shown to be significantly superior in terms of higher conformality if designed to simultaneously deliver high dose to the primary disease and lower dose to the subclinical disease or electively treated regions. We use the term 'simultaneous integrated boost' (SIB) to define such a treatment. The purpose of this paper is to develop suitable fractionation strategies based on radiobiological principles for clinical trials and routine use of IMRT of head and neck (HN) cancers. The fractionation strategies are intended to allow escalation of tumor dose while adequately sparing normal tissues outside the target volume and considering the tolerances of normal tissues embedded within the primary target volume. Methods and Materials: IMRT fractionation regimens are specified in terms of 'normalized total dose' (NTD), i.e., the biologically equivalent dose given in 2 Gy/fx. A linear-quadratic isoeffect formula is applied to convert NTDs into 'nominal' prescription doses. Nominal prescription doses for a high dose to the primary disease, an intermediate dose to regional microscopic disease, and lower dose to electively treated nodes are used for optimizing IMRT plans. The resulting nominal dose distributions are converted back into NTD distributions for the evaluation of treatment plans. Similar calculations for critical normal tissues are also performed. Methods developed were applied for the intercomparison of several HN treatment regimens, including conventional regimens used currently and in the past, as well as SIB strategies. This was accomplished by comparing the biologically equivalent NTD values for the gross tumor and regional disease, and bone, muscle, and mucosa embedded in the gross tumor volume. Results: (1) A schematic HN example was used to demonstrate that dose distributions for SIB IMRT are more conformal compared to dose distributions when IMRT is divided into

  19. Fission tracks diameters in glasses

    International Nuclear Information System (INIS)

    Garzon Ruiperez, L.; Veiguela, J.

    1974-01-01

    Standard glass microscope slides have been irradiated with fission fragments from the uranium. The etching track conditions have been the same for the series, having changed the etching time only for each specimen. For each glass, a minimum of 250 measurements of the tracks diameters have been made, the distributions of which are the bimodal type. Diameters-etching dependence with time is roughly lineal. Energy determinations have been made with the help of the diameters-energy relations. The calculated values agree very well with the know ones. (author) [es

  20. Diameter-dependent coloration of silver nanowires

    International Nuclear Information System (INIS)

    Stewart, Mindy S; Qiu Chao; Jiang Chaoyang; Kattumenu, Ramesh; Singamaneni, Srikanth

    2011-01-01

    Silver nanowires were synthesized with a green method and characterized with microscopic and diffractometric methods. The correlation between the colors of the nanowires deposited on a solid substrate and their diameters was explored. Silver nanowires that appear similar in color in the optical micrographs have very similar diameters as determined by atomic force microscopy. We have summarized the diameter-dependent coloration for these silver nanowires. An optical interference model was applied to explain such correlation. In addition, microreflectance spectra were obtained from individual nanowires and the observed spectra can be explained with the optical interference theory. This work provides a cheap, quick and simple screening method for studying the diameter distribution of silver nanowires, as well as the diameter variations of individual silver nanowires, without complicated sample preparation.

  1. Free-air ionization intensity in the lower atmosphere due to cosmic-ray

    International Nuclear Information System (INIS)

    Urabe, Itsumasa; Katsurayama, Kousuke

    1979-01-01

    Being able to be determined by subtracting the gamma-ray ionization intensity from that obtained with ionization chamber, cosmic-ray ionization intensity in free air was estimated by using with 15l air-filled ionization chamber and 3''diameter spherical NaI(Tl) scintillation spectrometer. Optimum applied voltage to 15l air-filled ionization chamber was determined in accordance with Scott and Greening's formula to obtain the ionization intensity caused by gamma-rays and cosmic-rays. Pulse-height distribution of cosmic-rays created in 3''diameter spherical NaI(Tl) scintillation spectrometer was investigated for the precise determination of gamma-ray ionization intensity. Field measurements were carried out by using with these two instruments at about 1.5 meter above the ground in the several locations around Research Reactor Institute of Kyoto University. Cosmic-ray ionization intensity in free air was estimated from the results obtained with air-filled ionization chamber and was 3.33 +- 0.15 μR/hr equivalent in natural environment near Research Reactor Institute of Kyoto University. (author)

  2. Left ventricular ejection fraction and left atrium diameter related to new-onset atrial fibrillation following acute myocardial infarction: a systematic review and meta-analysis.

    Science.gov (United States)

    Zeng, Rui-Xiang; Chen, Mao-Sheng; Lian, Bao-Tao; Liao, Peng-Da; Zhang, Min-Zhou

    2017-10-06

    New-onset atrial fibrillation (NOAF) occurs frequently in patients with acute myocardial infarction (AMI), and is associated with increased subsequent cardiovascular mortality. However, only a few studies directly evaluated the relationship of left ventricular ejection fraction (LVEF) or left atrium diameter (LAD) and NOAF following AMI. MEDLINE ® , EMBASE ® and the Cochrane Library were carried out to find studies until January 2017. Pooled mean difference (MD) and 95% confidence interval (CI) were calculated to evaluate the value of LVEF and LAD in the prediction of NOAF after AMI. We performed sensitivity analyses to explore the potential sources of heterogeneity. Statistical analyses were carried out using the Revman 5.3. We included 10 qualifying studies comprising a total of 708 patients with NOAF and 6785 controls. Overall, decreased LVEF and increased LAD levels had a significant positive association with NOAF in patients with AMI. The MD in the LVEF levels between the patients with and those without NOAF was -4.91 units (95% Cl: -5.70 to -4.12), test for overall effect z-score = 12.18 ( p < 0.00001, I 2 = 35%). Moreover, in a subgroup analysis, the MD for LAD and NOAF was 2.55 units (95% Cl: 1.91 to 3.19), test for overall effect z-score = 7.80 ( p < 0.00001, I 2 = 57%). Our meta-analysis demonstrated that both decreased LVEF and increased LAD levels were associated with greater risk of NOAF following AMI.

  3. Isotachophoresis system having larger-diameter channels flowing into channels with reduced diameter and with selectable counter-flow

    Energy Technology Data Exchange (ETDEWEB)

    Mariella, Jr., Raymond P.

    2018-03-06

    An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.

  4. 7 CFR 51.320 - Diameter.

    Science.gov (United States)

    2010-01-01

    ... Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter...

  5. Preparation of three-dimensionally ordered macroporous perovskite-type lanthanum-iron-oxide LaFeO3 with tunable pore diameters: High porosity and photonic property

    International Nuclear Information System (INIS)

    Sadakane, Masahiro; Horiuchi, Toshitaka; Kato, Nobuyasu; Sasaki, Keisuke; Ueda, Wataru

    2010-01-01

    Three-dimensionally ordered macroporous (3DOM) lanthanum-iron-oxide (LaFeO 3 ) with different pore diameters was prepared using a colloidal crystal of polymer spheres with different diameters as templates. Ethylene glycol-methanol mixed solution of metal nitrates was infiltrated into the void of the colloidal crystal template of a monodispersed poly(methyl methacrylate) (PMMA) sphere. Heating of this PMMA-metal salt-ethylene glycol composite produced the desired well-ordered 3DOM LaFeO 3 with a high pore fraction, which was confirmed by powder X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), mercury (Hg) porosimetry, and ultraviolet-visible (UV-vis) diffuse reflectance spectra. 3DOM LaFeO 3 with pore diameters of 281 and 321 nm shows opalescent colors because of photonic stop band properties. Catalytic activity of the 3DOM LaFeO 3 for combustion of carbon particles was enhanced by a potassium cation, which was involved from K 2 S 2 O 8 used as a polymerization initiator. - Graphical abstract: Well-ordered three-dimensionally ordered macroporous LaFeO 3 materials with pore sizes ranging from 127 to 321 nm were obtained in a high pore fraction.

  6. On the measurement of Wigner distribution moments in the fractional Fourier transform domain

    NARCIS (Netherlands)

    Bastiaans, M.J.; Alieva, T.

    2002-01-01

    It is shown how all global Wigner distribution moments of arbitrary order can be measured as intensity moments in the output plane of an appropriate number of fractional Fourier transform systems (generally anamorphic ones). The minimum number of (anamorphic) fractional power spectra that are needed

  7. Effects of aerosol polydispersity on theoretical calculations of unattached fractions of radon progeny

    International Nuclear Information System (INIS)

    Bandi, F.; Khan, A.; Phillips, C.R.

    1987-01-01

    Theoretical calculations of unattached fractions of radon progeny require prediction of an attachment coefficient. Average attachment coefficients for aerosols of various count median diameters, CMD, and geometric standard deviations, σ/sub g/, are calculated using four different theories. These theories are: (1) the kinetic theory, (2) the diffusion theory, (3) the hybrid theory and (4) the kinetic-diffusion theory. Comparisons of the various calculated attachment coefficients are made and the implications of using either the kinetic or the diffusion theory to calculate unattached fractions for aerosols of various CMD and σg are discussed. Significant errors may arise in use of either the kinetic theory or the diffusion theory. Large and unacceptable errors arise in calculating unattached fractions of a polydisperse aerosol by characterizing the aerosol as monodisperse. Unattached fractions of RaA are calculated for two mine aerosols and a room aerosol

  8. Transformations between Extensive and Intensive Versions of Thermodynamic Relationships

    Science.gov (United States)

    Eberhart, James G.

    2010-01-01

    Most thermodynamic properties are either extensive (e.g., volume, energy, entropy, amount, etc.) or intensive (e.g., temperature, pressure, chemical potential, mole fraction, etc.). By the same token most of the mathematical relationships in thermodynamics can be written in extensive or intensive form. The basic laws of thermodynamics are usually…

  9. Asymmetric flow field-flow fractionation of superferrimagnetic iron oxide multicore nanoparticles

    DEFF Research Database (Denmark)

    Dutz, Silvio; Kuntsche, Judith; Eberbeck, Dietmar

    2012-01-01

    Magnetic nanoparticles are very useful for various medical applications where each application requires particles with specific magnetic properties. In this paper we describe the modification of the magnetic properties of magnetic multicore nanoparticles (MCNPs) by size dependent fractionation....... The hysteresis curves were measured by vibrating sample magnetometry. Starting from a coercivity of 1.41 kA m(-1) for the original MCNPs the coercivity of the particles in the different fractions varied from 0.41 to 3.83 kA m(-1). In our paper it is shown for the first time that fractions obtained from a broad...... size distributed MCNP fluid classified by AF4 show a strong correlation between hydrodynamic diameter and magnetic properties. Thus we state that AF4 is a suitable technology for reproducible size dependent classification of magnetic multicore nanoparticles suspended as ferrofluids....

  10. Effects of light intensity on components and topographical structures of extracellular polysaccharides from the cyanobacteria Nostoc sp.

    Science.gov (United States)

    Ge, Hongmei; Xia, Ling; Zhou, Xuping; Zhang, Delu; Hu, Chunxiang

    2014-02-01

    A study on the effects of light intensity (40 and 80 μE/m(2)/sec) on the components and topographical structures of extracellular polysaccharides (EPS) was carried out in cyanobacteria Nostoc sp.. EPS yield increased with light intensity. However, light intensity did not significantly affect the EPS fractions and monosaccharide composition. Higher light intensity generally resulted in higher protein content of EPS in similar fractions. The topographical structure of EPS, investigated by atomic force microscopy, appeared as spherical lumps, chains and networks. The long chains were observed at higher light intensity. Thus, light intensity affected the yield and nature of EPS.

  11. Appendiceal diameter: CT versus sonographic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Orscheln, Emily S. [University of Cincinnati Medical Center, Department of Radiology, Cincinnati, OH (United States); Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States)

    2016-03-15

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  12. Appendiceal diameter: CT versus sonographic measurements

    International Nuclear Information System (INIS)

    Orscheln, Emily S.; Trout, Andrew T.

    2016-01-01

    Ultrasound and CT are the dominant imaging modalities for assessment of suspected pediatric appendicitis, and the most commonly applied diagnostic criterion for both modalities is appendiceal diameter. The classically described cut-off diameter for the diagnosis of appendicitis is 6 mm when using either imaging modality. To demonstrate the fallacy of using the same cut-off diameter for both CT and US in the diagnosis of appendicitis. We conducted a retrospective review of patients younger than 18 years who underwent both US and CT of the appendix within 24 h. The shortest transverse dimension of the appendix was measured at the level of the proximal, mid and distal appendix on US and CT images. We compared mean absolute difference in appendiceal diameter between US and CT, using the paired t-test. We reviewed exams of 155 children (58.7% female) with a mean age of 11.3 ± 4.2 years; 38 of the children (24.5%) were diagnosed with appendicitis. The average time interval between US and CT was 7.0 ± 5.4 h. Mean appendiceal diameter measured by CT was significantly larger than that measured by US in cases without appendicitis (5.3 ± 1.0 mm vs. 4.7 ± 1.1 mm, P < 0.0001) and in cases with appendicitis (8.3 ± 2.2 mm vs. 7.0 ± 2.0 mm, P < 0.0001). Mean absolute diameter difference at any location along the appendix was 1.3-1.4 mm in normal appendices and 2 mm in cases of appendicitis. Measured appendiceal diameter differs between US and CT by 1-2 mm, calling into question use of the same diameter cut-off (6 mm) for both modalities for the diagnosis of appendicitis. (orig.)

  13. Long-axis fractional shortening and mitral annulus motion in dogs

    Directory of Open Access Journals (Sweden)

    Marlos Gonçalves Sousa

    2016-10-01

    Full Text Available Ventricular systolic dynamics involves the contraction of transverse and longitudinal myocardial fibers. Unfortunately, only the activity of the transverse myocardial fibers is foreseen by the standard systolic echocardiographic parameters. Although strain and strain rate have been used to assess the radial, circumferential and longitudinal planes of cardiac contraction, such analysis requires advanced equipment which is not always available in veterinary medicine. On the contrary, some unusual parameters may be recorded via standard methodology, allowing for the specific evaluation of left ventricular longitudinal contractility. In this study, the longitudinal contractile activity was evaluated using the long-axis fractional shortening and the mitral annulus motion, which were compared with several standard echocardiographic parameters in 14 beagles, including seven with asymptomatic mitral valve disease. The long-axis fractional shortening was positively correlated with both the mitral annulus motion and the end-diastolic left-ventricular diameter. Also, a significant correlation was found to exist between the mitral annulus motion and the left-ventricular end-diastolic diameter, which is likely supportive of its preload dependency. Even though no difference was documented in either mitral annulus motion or long-axis fractional shortening between healthy dogs and dogs with mitral valve disease, the latter only included animals with minimal cardiac remodeling, with no overt compromise of systolic function. Since it is possible to obtain these two parameters with any echocardiographic equipment, their inclusion in the routine exam would probably add information regarding the activity of the longitudinal myocardial fibers, whose functional deterioration supposedly occurs prior to the impairment of transverse fibers.

  14. Mexametric and cutometric assessment of the signs of aging of the skin area around the eyes after the use of non-ablative fractional laser, non-ablative radiofrequency and intense pulsed light.

    Science.gov (United States)

    Kołodziejczak, Anna Maria; Rotsztejn, Helena

    2017-03-01

    The assessment of the signs of aging within eyes area in cutometric (skin elasticity) and mexametric (discoloration and severity of erythema) examination after the treatment with: non-ablative fractional laser, non-ablative radiofrequency (RF) and intense light source (IPL). This study included 71 patients, aged 33-63 years (the average age was 45.81) with Fitzpatrick skin type II and III. 24 patients received 5 successive treatment sessions with a 1,410-nm non-ablative fractional laser in two-week intervals, 23 patients received 5 successive treatment sessions with a non-ablative RF in one-week intervals and 24 patients received 5 successive treatment sessions with an IPL in two-week intervals. The treatment was performed for the skin in the eye area. The Cutometer and Mexameter (Courage + Khazaka electronic) reference test was used as an objective method for the assessment of skin properties: elasticity, skin pigmentation and erythema. Measurements of skin elasticity were made in three or four sites within eye area. The results of cutometric measurements for R7 showed the improvement in skin elasticity in case of all treatment methods. The largest statistically significant improvement (p measurements and for all methods, the greatest improvement in skin elasticity was demonstrated between the first and second measurement (after 3rd procedures). The majority of the results of mexametric measurements-MEX (melanin level) and ERYT (the severity of erythema) are statistically insignificant. Fractional, non-ablative laser, non-ablation RF and intense light source can be considered as methods significantly affecting elasticity and to a lesser extent erythema and skin pigmentation around the eyes. Fractional non-ablative laser is a method which, in comparison to other methods, has the greatest impact on skin viscoelasticity. These procedures are well tolerated and are associated with a low risk of side effects. © 2017 Wiley Periodicals, Inc.

  15. Gram-scale fractionation of nanodiamonds by density gradient ultracentrifugation

    KAUST Repository

    Peng, Wei

    2013-01-01

    Size is a defining characteristic of nanoparticles; it influences their optical and electronic properties as well as their interactions with molecules and macromolecules. Producing nanoparticles with narrow size distributions remains one of the main challenges to their utilization. At this time, the number of practical approaches to optimize the size distribution of nanoparticles in many interesting materials systems, including diamond nanocrystals, remains limited. Diamond nanocrystals synthesized by detonation protocols-so-called detonation nanodiamonds (DNDs)-are promising systems for drug delivery, photonics, and composites. DNDs are composed of primary particles with diameters mainly <10 nm and their aggregates (ca. 10-500 nm). Here, we introduce a large-scale approach to rate-zonal density gradient ultracentrifugation to obtain monodispersed fractions of nanoparticles in high yields. We use this method to fractionate a highly concentrated and stable aqueous solution of DNDs and to investigate the size distribution of various fractions by dynamic light scattering, analytical ultracentrifugation, transmission electron microscopy and powder X-ray diffraction. This fractionation method enabled us to separate gram-scale amounts of DNDs into several size ranges within a relatively short period of time. In addition, the high product yields obtained for each fraction allowed us to apply the fractionation method iteratively to a particular size range of particles and to collect various fractions of highly monodispersed primary particles. Our method paves the way for in-depth studies of the physical and optical properties, growth, and aggregation mechanism of DNDs. Applications requiring DNDs with specific particle or aggregate sizes are now within reach. © 2013 The Royal Society of Chemistry.

  16. Large effect of irradiance on hydrogen isotope fractionation of alkenones in Emiliania huxleyi

    Science.gov (United States)

    van der Meer, Marcel T. J.; Benthien, Albert; French, Katherine L.; Epping, Eric; Zondervan, Ingrid; Reichart, Gert-Jan; Bijma, Jelle; Sinninghe Damsté, Jaap S.; Schouten, Stefan

    2015-07-01

    The hydrogen isotopic (δD) composition of long-chain alkenones produced by certain haptophyte algae has been suggested as a potential proxy for reconstructing paleo sea surface salinity. However, environmental parameters other than salinity may also affect the δD of alkenones. We investigated the impact of the level of irradiance on hydrogen isotopic fractionation of alkenones versus growth water by cultivating two strains of the cosmopolitan haptophyte Emiliania huxleyi at different light intensities. The hydrogen isotope fractionation decreased by approximately 40‰ when irradiance was increased from 15 to 200 μmol photons m-2 s-1 above which it was relatively constant. The response is likely a direct effect of photosystem I and II activity as the relationship of the fractionation factor α versus light intensity can be described by an Eilers-Peeters photosynthesis model. This irradiance effect is in agreement with published δD data of alkenones derived from suspended particulate matter collected from different depths in the photic zone of the Gulf of California and the eastern tropical North Pacific. However, haptophyte algae tend to bloom at relatively high light intensities (>500 μmol photons m-2 s-1) occurring at the sea surface, at which hydrogen isotope fractionation is relatively constant and not affected by changes in light intensity. Alkenones accumulating in the sediment are likely mostly derived from these surface water haptophyte blooms, when the largest amount of biomass is produced. Therefore, the observed irradiance effect is unlikely to affect the applicability of the hydrogen isotopic composition of sedimentary long chain alkenones as a proxy for paleosalinity.

  17. Estimation of dependence between mean of fractionation of photons and neutrons dose and intensity of post-irradiation reaction of mouse large intestine

    International Nuclear Information System (INIS)

    Gasinska, A.

    1995-01-01

    The aim of the work was verification of mouse large intestine tolerance on fractionated 250 kV X-rays and 2.3 MeV neutrons doses. Two cm of large intestine of mouse CBA/HT strain were irradiated with various fraction doses: from 0.25 to 35 Gy of X-rays and 0.05-12 Gy of neutrons. The measure of injury was handicap of intestine function. Early post-irradiation reaction was measured by loss of body weight (2-3 weeks after irradiation) and mouse mortality (till 2 months after irradiation, LD50/2). The late reaction was measured on the base of maximal body weight in 1 year period after irradiation, deformation of excrements (after 10 months) and death of animals (till 12. month after irradiation, LD50/12). Fractionation of X-ray dose influenced on decrease of intensification of late irradiation effects. After fractionation of neutrons this effect has not been observed. α/β coefficient for X-rays was 19.9 Gy [15.2; 27.0] for body weight nadir, 13.4 Gy [9.3; 19.5] for early mortality (LD50/2), 6.4 Gy [3.6;11.0] for maximal body weight and 6.9 [4.2; 10.8] for late mortality (LD50/12). Analysis of influence of low doses of photons 90.25-4 Gy) and neutrons (0.05-0.8 Gy) showed trend to reduction α/β for photons only (LD50/2=5.4 Gy; LD50/12=4.6 Gy). α/β coefficient for neutrons was defined by LQ model only for maximal body weight and was 19.9 Gy [9.5; 61.0]. In application of graphic method α/β for neutrons was 230 Gy for early and 48 Gy for late effects. Lower values of α/β coefficient for late irradiation effects for photon radiation demonstrate the big influence of fractionation of photons dose on large intestine tolerance (decrease intensity in all biological effects). Author did not observe increase of intestine tolerance in fractionation of neutrons dose. Effect of irradiation damages repair in interfraction pauses, measured by percent of regenerated dose (F r ) was much bigger for photons. For X-rays it was 50% for early and 63% for late effects. In case of

  18. Acoustic programming in step-split-flow lateral-transport thin fractionation.

    Science.gov (United States)

    Ratier, Claire; Hoyos, Mauricio

    2010-02-15

    We propose a new separation scheme for micrometer-sized particles combining acoustic forces and gravitational field in split-flow lateral-transport thin (SPLITT)-like fractionation channels. Acoustic forces are generated by ultrasonic standing waves set up in the channel thickness. We report on the separation of latex particles of two different sizes in a preliminary experiment using this proposed hydrodynamic acoustic sorter, HAS. Total binary separation of 5 and 10 microm diameter particles has been achieved. Numerical simulations of trajectories of particles flowing through a step-SPLITT under the conditions which combine acoustic standing waves and gravity show a very good agreement with the experiment. Calculations in order to compare separations obtained by the acoustic programming s-SPLITT fractionation and the conventional SPLITT fractionation show that the improvement in separation time is around 1 order of magnitude and could still be improved; this is the major finding of this work. This separation technique can be extended to biomimetic particles and blood cells.

  19. Alveolar bone-loss area localization in periodontitis radiographs based on threshold segmentation with a hybrid feature fused of intensity and the H-value of fractional Brownian motion model.

    Science.gov (United States)

    Lin, P L; Huang, P W; Huang, P Y; Hsu, H C

    2015-10-01

    Periodontitis involves progressive loss of alveolar bone around the teeth. Hence, automatic alveolar bone-loss (ABL) measurement in periapical radiographs can assist dentists in diagnosing such disease. In this paper, we propose an effective method for ABL area localization and denote it as ABLIfBm. ABLIfBm is a threshold segmentation method that uses a hybrid feature fused of both intensity and texture measured by the H-value of fractional Brownian motion (fBm) model, where the H-value is the Hurst coefficient in the expectation function of a fBm curve (intensity change) and is directly related to the value of fractal dimension. Adopting leave-one-out cross validation training and testing mechanism, ABLIfBm trains weights for both features using Bayesian classifier and transforms the radiograph image into a feature image obtained from a weighted average of both features. Finally, by Otsu's thresholding, it segments the feature image into normal and bone-loss regions. Experimental results on 31 periodontitis radiograph images in terms of mean true positive fraction and false positive fraction are about 92.5% and 14.0%, respectively, where the ground truth is provided by a dentist. The results also demonstrate that ABLIfBm outperforms (a) the threshold segmentation method using either feature alone or a weighted average of the same two features but with weights trained differently; (b) a level set segmentation method presented earlier in literature; and (c) segmentation methods based on Bayesian, K-NN, or SVM classifier using the same two features. Our results suggest that the proposed method can effectively localize alveolar bone-loss areas in periodontitis radiograph images and hence would be useful for dentists in evaluating degree of bone-loss for periodontitis patients. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. Indirect and direct methods for measuring a dynamic throat diameter in a solid rocket motor

    Science.gov (United States)

    Colbaugh, Lauren

    In a solid rocket motor, nozzle throat erosion is dictated by propellant composition, throat material properties, and operating conditions. Throat erosion has a significant effect on motor performance, so it must be accurately characterized to produce a good motor design. In order to correlate throat erosion rate to other parameters, it is first necessary to know what the throat diameter is throughout a motor burn. Thus, an indirect method and a direct method for determining throat diameter in a solid rocket motor are investigated in this thesis. The indirect method looks at the use of pressure and thrust data to solve for throat diameter as a function of time. The indirect method's proof of concept was shown by the good agreement between the ballistics model and the test data from a static motor firing. The ballistics model was within 10% of all measured and calculated performance parameters (e.g. average pressure, specific impulse, maximum thrust, etc.) for tests with throat erosion and within 6% of all measured and calculated performance parameters for tests without throat erosion. The direct method involves the use of x-rays to directly observe a simulated nozzle throat erode in a dynamic environment; this is achieved with a dynamic calibration standard. An image processing algorithm is developed for extracting the diameter dimensions from the x-ray intensity digital images. Static and dynamic tests were conducted. The measured diameter was compared to the known diameter in the calibration standard. All dynamic test results were within +6% / -7% of the actual diameter. Part of the edge detection method consists of dividing the entire x-ray image by an average pixel value, calculated from a set of pixels in the x-ray image. It was found that the accuracy of the edge detection method depends upon the selection of the average pixel value area and subsequently the average pixel value. An average pixel value sensitivity analysis is presented. Both the indirect

  1. Intensity-modulated radiation therapy.

    Science.gov (United States)

    Goffman, Thomas E; Glatstein, Eli

    2002-07-01

    Intensity-modulated radiation therapy (IMRT) is an increasingly popular technical means of tightly focusing the radiation dose around a cancer. As with stereotactic radiotherapy, IMRT uses multiple fields and angles to converge on the target. The potential for total dose escalation and for escalation of daily fraction size to the gross cancer is exciting. The excitement, however, has greatly overshadowed a range of radiobiological and clinical concerns.

  2. Surface tension effects on vertical upward annular flows in a small diameter pipe

    Energy Technology Data Exchange (ETDEWEB)

    Sadatomi, Michio, E-mail: sadatomi@mech.kumamoto-u.ac.jp [Dept. of Advanced Mechanical Systems, Kumamoto Univ., 39-1, Kurokami 2-chome, Chuou-ku, Kumamoto 860-8555 (Japan); Kawahara, Akimaro [Dept. of Advanced Mechanical Systems, Kumamoto Univ., 39-1, Kurokami 2-chome, Chuou-ku, Kumamoto 860-8555 (Japan); Suzuki, Aruta [Plant Design & Engineering Dept., Environment, Energy & Plant Headquarters, Hitachi Zosen Corporation, 7-89, Nankokita 1-chome, Suminoe-ku, Osaka, 559-8559 (Japan)

    2016-12-15

    Highlights: • Surface tension effects were clarified on annular flow in a small diameter pipe. • The mean liquid film thickness became thinner with decreasing of surface tension. • The liquid droplet fraction and the interfacial shear stress became higher with it. • New prediction methods for the above parameters were developed and validated. - Abstract: Experiments were conducted to study the surface tension effects on vertical upward annular flows in a 5 mm I.D. pipe using water and low surface tension water with a little surfactant as the test liquid and air as the test gas. Firstly, the experimental results on the mean liquid film thickness, the liquid droplet fraction and the interfacial shear stress in annular flows together with some flow pictures are presented to clarify the surface tension effects. From these, the followings are clarified: In the low surface tension case, the liquid film surface becomes rough, the liquid film thickness thin, the liquid droplet fraction high, and the interfacial shear stress high. Secondary, correlations in literatures for the respective parameters are tested against the present data. The test results show that no correlation for the respective parameters could predict well the present data. Thus, correlations are revised by accounting for the surface tension effects. The results of the experiments, the correlations tests and their revisions mentioned above are presented in the present paper.

  3. Nineteen-Foot Diameter Explosively Driven Blast Simulator; TOPICAL

    International Nuclear Information System (INIS)

    VIGIL, MANUEL G.

    2001-01-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels

  4. Fitting diameter distribution models to data from forest inventories with concentric plot design

    Energy Technology Data Exchange (ETDEWEB)

    Nanos, N.; Sjöstedt de Luna, S.

    2017-11-01

    Aim: Several national forest inventories use a complex plot design based on multiple concentric subplots where smaller diameter trees are inventoried when lying in the smaller-radius subplots and ignored otherwise. Data from these plots are truncated with threshold (truncation) diameters varying according to the distance from the plot centre. In this paper we designed a maximum likelihood method to fit the Weibull diameter distribution to data from concentric plots. Material and methods: Our method (M1) was based on multiple truncated probability density functions to build the likelihood. In addition, we used an alternative method (M2) presented recently. We used methods M1 and M2 as well as two other reference methods to estimate the Weibull parameters in 40000 simulated plots. The spatial tree pattern of the simulated plots was generated using four models of spatial point patterns. Two error indices were used to assess the relative performance of M1 and M2 in estimating relevant stand-level variables. In addition, we estimated the Quadratic Mean plot Diameter (QMD) using Expansion Factors (EFs). Main results: Methods M1 and M2 produced comparable estimation errors in random and cluster tree spatial patterns. Method M2 produced biased parameter estimates in plots with inhomogeneous Poisson patterns. Estimation of QMD using EFs produced biased results in plots within inhomogeneous intensity Poisson patterns. Research highlights:We designed a new method to fit the Weibull distribution to forest inventory data from concentric plots that achieves high accuracy and precision in parameter estimates regardless of the within-plot spatial tree pattern.

  5. Transition from fractional to classical Stokes-Einstein behaviour in simple fluids.

    Science.gov (United States)

    Coglitore, Diego; Edwardson, Stuart P; Macko, Peter; Patterson, Eann A; Whelan, Maurice

    2017-12-01

    An optical technique for tracking single particles has been used to evaluate the particle diameter at which diffusion transitions from molecular behaviour described by the fractional Stokes-Einstein relationship to particle behaviour described by the classical Stokes-Einstein relationship. The results confirm a prior prediction from molecular dynamic simulations that there is a particle size at which transition occurs and show it is inversely dependent on concentration and viscosity but independent of particle density. For concentrations in the range 5 × 10 -3 to 5 × 10 -6  mg ml -1 and viscosities from 0.8 to 150 mPa s, the transition was found to occur in the diameter range 150-300 nm.

  6. U-PHOS Project: Development of a Large Diameter Pulsating Heat Pipe Experiment on board REXUS 22

    International Nuclear Information System (INIS)

    Nannipieri, P; Anichini, M; Barsocchi, L; Becatti, G; Buoni, L; Celi, F; Catarsi, A; Di Giorgio, P; Fattibene, P; Ferrato, E; Guardati, P; Mancini, E; Meoni, G; Nesti, F; Piacquadio, S; Pratelli, E; Quadrelli, L; Viglione, A S; Zanaboni, F; Mameli, M

    2017-01-01

    U-PHOS Project aims at analysing and characterising the behaviour of a large diameter Pulsating Heat Pipe (PHP) on board REXUS 22 sounding rocket. A PHP is a passive thermal control device where the heat is efficiently transported by means of the self-sustained oscillatory fluid motion driven by the phase change phenomena. Since, in milli-gravity conditions, buoyancy forces become less intense, the PHP diameter may be increased still maintaining the slug/plug typical flow pattern. Consequently, the PHP heat power capability may be increased too. U-PHOS aims at proving that a large diameter PHP effectively works in milli-g conditions by characterizing its thermal response during a sounding rocket flight. The actual PHP tube is made of aluminum (3 mm inner diameter, filled with FC-72), heated at the evaporator by a compact electrical resistance, cooled at the condenser by a Phase Change Material (PCM) embedded in a metallic foam. The tube wall temperatures are recorded by means of Fibre Bragg Grating (FBG) sensors; the local fluid pressure is acquired by means of a pressure transducer. The present work intends to report the actual status of the project, focusing in particular on the experiment improvements with respect to the previous campaign. (paper)

  7. Diameter 2 properties and convexity

    Czech Academy of Sciences Publication Activity Database

    Abrahamsen, T. A.; Hájek, Petr Pavel; Nygaard, O.; Talponen, J.; Troyanski, S.

    2016-01-01

    Roč. 232, č. 3 (2016), s. 227-242 ISSN 0039-3223 R&D Projects: GA ČR GA16-07378S Institutional support: RVO:67985840 Keywords : diameter 2 property * midpoint locally uniformly rotund * Daugavet property Subject RIV: BA - General Mathematics Impact factor: 0.535, year: 2016 https://www.impan.pl/pl/wydawnictwa/czasopisma-i-serie-wydawnicze/studia- mathematica /all/232/3/91534/diameter-2-properties-and-convexity

  8. Displacer Diameter Effect in Displacer Pulse Tube Refrigerator

    Science.gov (United States)

    Zhu, Shaowei

    2017-12-01

    Gas driving displacer pulse tube refrigerators are one of the work recovery type of pulse tube refrigerators whose theoretical efficiency is the same as Stirling refrigerators'. Its cooling power is from the displacement of the displacer. Displace diameter, rod diameter and pressure drop of the regenerator influence the displacement, which are investigated by numerical simulation. It is shown that the displacement ratio of the displacer over the piston is almost not affected by the displacer diameter at the same rod diameter ratio, or displacer with different diameters almost has the same performance.

  9. Spatiotemporal Fractionation Schemes for Irradiating Large Cerebral Arteriovenous Malformations

    Energy Technology Data Exchange (ETDEWEB)

    Unkelbach, Jan, E-mail: junkelbach@mgh.harvard.edu [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Bussière, Marc R. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Chapman, Paul H. [Department of Neurosurgery, Massachusetts General Hospital, Boston, Massachusetts (United States); Loeffler, Jay S.; Shih, Helen A. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States)

    2016-07-01

    Purpose: To optimally exploit fractionation effects in the context of radiosurgery treatments of large cerebral arteriovenous malformations (AVMs). In current practice, fractionated treatments divide the dose evenly into several fractions, which generally leads to low obliteration rates. In this work, we investigate the potential benefit of delivering distinct dose distributions in different fractions. Methods and Materials: Five patients with large cerebral AVMs were reviewed and replanned for intensity modulated arc therapy delivered with conventional photon beams. Treatment plans allowing for different dose distributions in all fractions were obtained by performing treatment plan optimization based on the cumulative biologically effective dose delivered at the end of treatment. Results: We show that distinct treatment plans can be designed for different fractions, such that high single-fraction doses are delivered to complementary parts of the AVM. All plans create a similar dose bath in the surrounding normal brain and thereby exploit the fractionation effect. This partial hypofractionation in the AVM along with fractionation in normal brain achieves a net improvement of the therapeutic ratio. We show that a biological dose reduction of approximately 10% in the healthy brain can be achieved compared with reference treatment schedules that deliver the same dose distribution in all fractions. Conclusions: Boosting complementary parts of the target volume in different fractions may provide a therapeutic advantage in fractionated radiosurgery treatments of large cerebral AVMs. The strategy allows for a mean dose reduction in normal brain that may be valuable for a patient population with an otherwise normal life expectancy.

  10. Impact of fractionation on out-of-field survival and DNA damage responses following exposure to intensity modulated radiation fields

    Science.gov (United States)

    Ghita, Mihaela; Coffey, Caroline B.; Butterworth, Karl T.; McMahon, Stephen J.; Schettino, Giuseppe; Prise, Kevin M.

    2016-01-01

    To limit toxicity to normal tissues adjacent to the target tumour volume, radiotherapy is delivered using fractionated regimes whereby the total prescribed dose is given as a series of sequential smaller doses separated by specific time intervals. The impact of fractionation on out-of-field survival and DNA damage responses was determined in AGO-1522 primary human fibroblasts and MCF-7 breast tumour cells using uniform and modulated exposures delivered using a 225 kVp x-ray source. Responses to fractionated schedules (two equal fractions delivered with time intervals from 4 h to 48 h) were compared to those following acute exposures. Cell survival and DNA damage repair measurements indicate that cellular responses to fractionated non-uniform exposures differ from those seen in uniform exposures for the investigated cell lines. Specifically, there is a consistent lack of repair observed in the out-of-field populations during intervals between fractions, confirming the importance of cell signalling to out-of-field responses in a fractionated radiation schedule, and this needs to be confirmed for a wider range of cell lines and conditions.

  11. Impact of fractionation on out-of-field survival and DNA damage responses following exposure to intensity modulated radiation fields

    International Nuclear Information System (INIS)

    Ghita, Mihaela; Butterworth, Karl T; McMahon, Stephen J; Prise, Kevin M; Coffey, Caroline B; Schettino, Giuseppe

    2016-01-01

    To limit toxicity to normal tissues adjacent to the target tumour volume, radiotherapy is delivered using fractionated regimes whereby the total prescribed dose is given as a series of sequential smaller doses separated by specific time intervals. The impact of fractionation on out-of-field survival and DNA damage responses was determined in AGO-1522 primary human fibroblasts and MCF-7 breast tumour cells using uniform and modulated exposures delivered using a 225 kVp x-ray source. Responses to fractionated schedules (two equal fractions delivered with time intervals from 4 h to 48 h) were compared to those following acute exposures. Cell survival and DNA damage repair measurements indicate that cellular responses to fractionated non-uniform exposures differ from those seen in uniform exposures for the investigated cell lines. Specifically, there is a consistent lack of repair observed in the out-of-field populations during intervals between fractions, confirming the importance of cell signalling to out-of-field responses in a fractionated radiation schedule, and this needs to be confirmed for a wider range of cell lines and conditions. (paper)

  12. The transverse diameter of the chest on routine radiographs reliably estimates gestational age and weight in premature infants.

    Science.gov (United States)

    Dietz, Kelly R; Zhang, Lei; Seidel, Frank G

    2015-08-01

    Prior to digital radiography it was possible for a radiologist to easily estimate the size of a patient on an analog film. Because variable magnification may be applied at the time of processing an image, it is now more difficult to visually estimate an infant's size on the monitor. Since gestational age and weight significantly impact the differential diagnosis of neonatal diseases and determine the expected size of kidneys or appearance of the brain by MRI or US, this information is useful to a pediatric radiologist. Although this information may be present in the electronic medical record, it is frequently not readily available to the pediatric radiologist at the time of image interpretation. To determine if there was a correlation between gestational age and weight of a premature infant with their transverse chest diameter (rib to rib) on admission chest radiographs. This retrospective study was approved by the institutional review board, which waived informed consent. The maximum transverse chest diameter outer rib to outer rib was measured on admission portable chest radiographs of 464 patients admitted to the neonatal intensive care unit (NICU) during the 2010 calendar year. Regression analysis was used to investigate the association between chest diameter and gestational age/birth weight. Quadratic term of chest diameter was used in the regression model. Chest diameter was statistically significantly associated with both gestational age (P chest diameter on digital chest radiograph with the tables and graphs in our study.

  13. Intensive lifestyle changes for reversal of coronary heart disease.

    Science.gov (United States)

    Ornish, D; Scherwitz, L W; Billings, J H; Brown, S E; Gould, K L; Merritt, T A; Sparler, S; Armstrong, W T; Ports, T A; Kirkeeide, R L; Hogeboom, C; Brand, R J

    1998-12-16

    The Lifestyle Heart Trial demonstrated that intensive lifestyle changes may lead to regression of coronary atherosclerosis after 1 year. To determine the feasibility of patients to sustain intensive lifestyle changes for a total of 5 years and the effects of these lifestyle changes (without lipid-lowering drugs) on coronary heart disease. Randomized controlled trial conducted from 1986 to 1992 using a randomized invitational design. Forty-eight patients with moderate to severe coronary heart disease were randomized to an intensive lifestyle change group or to a usual-care control group, and 35 completed the 5-year follow-up quantitative coronary arteriography. Two tertiary care university medical centers. Intensive lifestyle changes (10% fat whole foods vegetarian diet, aerobic exercise, stress management training, smoking cessation, group psychosocial support) for 5 years. Adherence to intensive lifestyle changes, changes in coronary artery percent diameter stenosis, and cardiac events. Experimental group patients (20 [71%] of 28 patients completed 5-year follow-up) made and maintained comprehensive lifestyle changes for 5 years, whereas control group patients (15 [75%] of 20 patients completed 5-year follow-up) made more moderate changes. In the experimental group, the average percent diameter stenosis at baseline decreased 1.75 absolute percentage points after 1 year (a 4.5% relative improvement) and by 3.1 absolute percentage points after 5 years (a 7.9% relative improvement). In contrast, the average percent diameter stenosis in the control group increased by 2.3 percentage points after 1 year (a 5.4% relative worsening) and by 11.8 percentage points after 5 years (a 27.7% relative worsening) (P=.001 between groups. Twenty-five cardiac events occurred in 28 experimental group patients vs 45 events in 20 control group patients during the 5-year follow-up (risk ratio for any event for the control group, 2.47 [95% confidence interval, 1.48-4.20]). More regression

  14. Diameter effect on critical heat flux

    International Nuclear Information System (INIS)

    Tanase, A.; Cheng, S.C.; Groeneveld, D.C.; Shan, J.Q.

    2009-01-01

    The critical heat flux look-up table (CHF LUT) is widely used to predict CHF for various applications, including design and safety analysis of nuclear reactors. Using the CHF LUT for round tubes having inside diameters different from the reference 8 mm involves conversion of CHF to 8 mm. Different authors [Becker, K.M., 1965. An Analytical and Experimental Study of Burnout Conditions in Vertical Round Ducts, Aktiebolaget Atomenergie Report AE 177, Sweden; Boltenko, E.A., et al., 1989. Effect of tube diameter on CHF at various two phase flow regimes, Report IPE-1989; Biasi, L., Clerici, G.C., Garriba, S., Sala, R., Tozzi, A., 1967. Studies on Burnout, Part 3, Energia Nucleare, vol. 14, pp. 530-536; Groeneveld, D.C., Cheng, S.C., Doan, T., 1986. AECL-UO critical heat flux look-up table. Heat Transfer Eng., 7, 46-62; Groeneveld et al., 1996; Hall, D.D., Mudawar, I., 2000. Critical heat flux for water flow in tubes - II subcooled CHF correlations. Int. J. Heat Mass Transfer, 43, 2605-2640; Wong, W.C., 1996. Effect of tube diameter on critical heat flux, MaSC dissertation, Ottawa Carleton Institute for Mechanical and Aeronautical Engineering, University of Ottawa] have proposed several types of correlations or factors to describe the diameter effect on CHF. The present work describes the derivation of new diameter correction factor and compares it with several existing prediction methods

  15. Abnormal splenic artery diameter/hepatic artery diameter ratio in cirrhosis-induced portal hypertension

    Science.gov (United States)

    Zeng, Dao-Bing; Dai, Chuan-Zhou; Lu, Shi-Chun; He, Ning; Wang, Wei; Li, Hong-Jun

    2013-01-01

    AIM: To determine an optimal cutoff value for abnormal splenic artery diameter/proper hepatic artery diameter (S/P) ratio in cirrhosis-induced portal hypertension. METHODS: Patients with cirrhosis and portal hypertension (n = 770) and healthy volunteers (n = 31) underwent volumetric computed tomography three-dimensional vascular reconstruction to measure the internal diameters of the splenic artery and proper hepatic artery to calculate the S/P ratio. The cutoff value for abnormal S/P ratio was determined using receiver operating characteristic curve analysis, and the prevalence of abnormal S/P ratio and associations between abnormal S/P ratio and major complications of portal hypertension were studied using logistic regression. RESULTS: The receiver operating characteristic analysis showed that the cutoff points for abnormal splenic artery internal diameter and S/P ratio were > 5.19 mm and > 1.40, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.2%, 45.2%, 97.1%, and 6.6%, respectively. The prevalence of an abnormal S/P ratio in the patients with cirrhosis and portal hypertension was 83.4%. Patients with a higher S/P ratio had a lower risk of developing ascites [odds ratio (OR) = 0.708, 95%CI: 0.508-0.986, P = 0.041] and a higher risk of developing esophageal and gastric varices (OR = 1.483, 95%CI: 1.010-2.175, P = 0.044) and forming collateral circulation (OR = 1.518, 95%CI: 1.033-2.230, P = 0.034). After splenectomy, the portal venous pressure and maximum and mean portal venous flow velocities were reduced, while the flow rate and maximum and minimum flow velocities of the hepatic artery were increased (P portal hypertension, and it can be used as an important marker of splanchnic hemodynamic disturbances. PMID:23483462

  16. The Pricing of Vulnerable Options in a Fractional Brownian Motion Environment

    Directory of Open Access Journals (Sweden)

    Chao Wang

    2015-01-01

    Full Text Available Under the assumption of the stock price, interest rate, and default intensity obeying the stochastic differential equation driven by fractional Brownian motion, the jump-diffusion model is established for the financial market in fractional Brownian motion setting. With the changes of measures, the traditional pricing method is simplified and the general pricing formula is obtained for the European vulnerable option with stochastic interest rate. At the same time, the explicit expression for it comes into being.

  17. Database and prediction model for CANDU pressure tube diameter

    Energy Technology Data Exchange (ETDEWEB)

    Jung, J.Y.; Park, J.H. [Korea Atomic Energy Research Inst., Daejeon (Korea, Republic of)

    2014-07-01

    The pressure tube (PT) diameter is basic data in evaluating the CCP (critical channel power) of a CANDU reactor. Since the CCP affects the operational margin directly, an accurate prediction of the PT diameter is important to assess the operational margin. However, the PT diameter increases by creep owing to the effects of irradiation by neutron flux, stress, and reactor operating temperatures during the plant service period. Thus, it has been necessary to collect the measured data of the PT diameter and establish a database (DB) and develop a prediction model of PT diameter. Accordingly, in this study, a DB for the measured PT diameter data was established and a neural network (NN) based diameter prediction model was developed. The established DB included not only the measured diameter data but also operating conditions such as the temperature, pressure, flux, and effective full power date. The currently developed NN based diameter prediction model considers only extrinsic variables such as the operating conditions, and will be enhanced to consider the effect of intrinsic variables such as the micro-structure of the PT material. (author)

  18. Study on combustion characteristics of dimethyl ether under the moderate or intense low-oxygen dilution condition

    International Nuclear Information System (INIS)

    Kang, Yinhu; Lu, Tianfeng; Lu, Xiaofeng; Wang, Quanhai; Huang, Xiaomei; Peng, Shini; Yang, Dong; Ji, Xuanyu; Song, Yangfan

    2016-01-01

    Highlights: • Oxygen content in the flame base increased due to the prolonged ignition delay time. • Flow field in the furnace affected thermal/chemical structure of the flame partially. • Preheating and dilution facilitated moderate or intense low-oxygen dilution regime. • Dominant pollutant formation ways of dimethyl ether in hot dilution were clarified. • Preheating and dilution reduced nitrogen oxide emission of dimethyl ether. - Abstract: Experiments and numerical simulations were conducted in this paper to study the combustion behavior of dimethyl ether in the moderate or intense low-oxygen dilution regime, in terms of thermal/chemical structure and chemical kinetics associated with nitrogen oxide and carbon monoxide emissions. Several co-flow temperatures and oxygen concentrations were involved in the experiments to investigate their impacts on the flame behavior systematically. The results show that in the moderate or intense low-oxygen dilution regime, oxygen concentrations in the flame base slightly increased because of the prolonged ignition delay time of the reactant mixture due to oxidizer dilution, which changed the local combustion process and composition considerably. The oxidation rates of hydrocarbons were significantly depressed in the moderate or intense low-oxygen dilution regime, such that a fraction of unburned hydrocarbons at the furnace outlet were recirculated into the outer annulus of the furnace, which changed the local radial profiles of carbon monoxide, methane, and hydrogen partially. Moreover, with the increment in co-flow temperature or oxygen mole fraction, flame temperature, and hydroxyl radical, carbon monoxide, and hydrogen mole fractions across the reaction zone increased gradually. For the dimethyl ether-moderate or intense low-oxygen dilution flame, temperature homogeneity was improved at higher co-flow temperature or lower oxygen mole fraction. The carbon monoxide emission depended on the levels of temperature and

  19. Continuous single pulse resolved measurement of beam diameters at 200 kHz using optical transmission filters

    Science.gov (United States)

    Fruechtenicht, Johannes; Letsch, Andreas; Voss, Andreas; Abdou Ahmed, Marwan; Graf, Thomas

    2012-02-01

    We present a novel laser beam measurement setup which allows the determination of the beam diameter for each single pulse of a pulsed laser beam at repetition rates of up to 200 kHz. This is useful for online process-parameter control e.g. in micromachining or for laser source characterization. Basically, the developed instrument combines spatial transmission filters specially designed for instantaneous optical determination of the second order moments of the lateral intensity distribution of the light beam and photodiodes coupled to customized electronics. The acquisition is computer-based, enabling real-time operation for online monitoring or control. It also allows data storage for a later analysis and visualization of the measurement results. The single-pulse resolved beam diameter can be measured and recorded without any interruption for an unlimited number of pulses. It is only limited by the capacity of the data storage means. In our setup a standard PC and hard-disk provided 2 hours uninterrupted operation and recording of varying beam diameters at 200 kHz. This is about three orders of magnitude faster than other systems. To calibrate our device we performed experiments in cw and pulsed regimes and the obtained results were compared to those obtained with a commercial camera based system. Only minor deviations of the beam diameter values between the two instruments were observed, proving the reliability of our approach.

  20. Measurements of Bismuth (214Bi) in Indoor Air and Evaluation of Deposition Fraction

    International Nuclear Information System (INIS)

    Mohamed, A.; Ahmed, A.A.; Yuness, M.

    2010-01-01

    The activity size distribution of unattached as well as attached 214 Bi to aerosol particles was measured in indoor air of physics department at Minia University, Minia City, Egypt. The samples were collected using a wire screen diffusion battery technique and a low pressure Berner cascade impactor. The mean Activity Median Thermodynamic Diameter (AMTD) of unattached 214 Bi was determined to be 1.25 nm with a relative mean Geometric Standard Deviation (GSD) of 1.29. A mean unattached fraction (fun) of 0.08±0.05 was obtained. The average activity concentration of 214 Bi was found to be 4.9±0.42 Bq m -3 . Most of the attached activities of progeny were associated with aerosol particles of the accumulation mode. The GSD of the accumulation mode of 214 Bi was determined to be 3 with an Active Median Aerodynamic Diameter (AMAD) of 350 nm. Based on the obtained measured data values, deposition fraction of 214 Bi has been evaluated by using a stochastic deposition model. The bronchial deposition efficiencies of particles in the size range of attached 214 Bi were found to be lower than those of unattached progeny

  1. Effect of Diabetes Condition on Topical Treatment of Binahong Leaf Fraction in Wound Healing Process

    Directory of Open Access Journals (Sweden)

    Kintoko Kintoko

    2017-08-01

    Full Text Available Diabetes mellitus (DM is a metabolic disease which is becoming the first number of health problem in Indonesia, based on the results of the Basic Health Research of Ministry of Health in 2013. One of the diabetes complications affected by high levels of blood glucose is diabetic ulcers wich 85% the number of cases was overed by amputation as the result of improper handling. Herbal treatments could be an alternative treatment of diabetic ulcers, one of them is binahong plant. The results of previous studies have shown the ability of ethanolic extract of binahong leaf in accelerating wound healing in diabetic rats. This study would be a continued study to test five kinds of binahong leaf fractions (FDB with gradual solvent polarity in accelerating wound healing in diabetic ulcer. Wound healing parameters observed were percentage of wound healing from the wound diameter contraction. The test begins with ethanolic extract of binahong leaf fractionation to produce fractions of hexane (FHDB, chloroform (FKDB, ethyl acetate (FEADB, and ethanol (FEDB. Water fraction (FADB was obtained from ethanolic leaf extract residues of binahong leaf extraction. Each fraction activity was tested topically twice daily on dorsal of test animals that created wounds using a punch biopsy 5 mm diameters. Grouping of test animals were divided into 13 groups with normal control group (non diabetes, negative control (diabetes + topical application of biocream®, positive control (diabetes + topical application of madecassol, and 10 diabetes groups with topical application of 5 kinds of binahong leaf fractions with each fractions consist of a concentrations of 5% and 10% with biocream® as a vehicle. Diabetic parameters measured include blood glucose levels (KGD and weight lost percentage (PB% in day 1 and 10 during a 10-day treatment. The results showed the influence of KGD in the condition of diabetes on wound healing rats diabetic ulcers which topically treated with

  2. Effect of material flows on energy intensity in process industries

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Liru; Aye, Lu [International Technologies Center (IDTC), Department of Civil and Environmental Engineering, The University of Melbourne, Victoria 3010 (Australia); Lu, Zhongwu [Institute of Materials and Metallurgy, Northeastern University, Shenyang 110004 (China); Zhang, Peihong [Department of Municipal and Environmental Engineering, Shenyang Architecture University, Shenyang 110168 (China)

    2006-09-15

    Many energy-intensive process industries have complex material flows, which have a strong effect on the overall energy intensity of the final product (OEIF). This problem, however, has only been recognised qualitatively due to the lack of quantitative analysis methods. This paper presents an in-depth quantitative analysis of the effect of material flows on energy intensity in process industries. Based on the concept of a standard material flow diagram (SMFD), as used in steel manufacturing, the SMFD for a generic process industry was first developed. Then material flow scenarios were addressed in a practical material flow diagram (PMFD) using the characteristics of practical process industries. The effect of each material flow deviating from a SMFD on the OEIF was analysed. The steps involved in analysing the effect of material flows in a PMFD on its energy intensity are also discussed in detail. Finally, using 1999 statistical data from the Chinese Zhenzhou alumina refinery plant, the PMFD and SMFD for this plant were constructed as a case study. The effect of material flows on the overall energy intensity of alumina (OEIA) was thus analysed quantitatively. To decrease OEIA, the process variations which decrease the product ratios could be employed in all except in multi-supplied fraction cases. In these cases, the fractions from the stream with lower energy intensities should be increased. (author)

  3. Turbulent flow in a vessel agitated by side entering inclined blade turbine with different diameter using CFD simulation

    Science.gov (United States)

    Fathonah, N. N.; Nurtono, T.; Kusdianto; Winardi, S.

    2018-03-01

    Single phase turbulent flow in a vessel agitated by side entering inclined blade turbine has simulated using CFD. The aim of this work is to identify the hydrodynamic characteristics of a model vessel, which geometrical configuration is adopted at industrial scale. The laboratory scale model vessel is a flat bottomed cylindrical tank agitated by side entering 4-blade inclined blade turbine with impeller rotational speed N=100-400 rpm. The effect of the impeller diameter on fluid flow pattern has been investigated. The fluid flow patterns in a vessel is essentially characterized by the phenomena of macro-instabilities, i.e. the flow patterns change with large scale in space and low frequency. The intensity of fluid flow in the tank increase with the increase of impeller rotational speed from 100, 200, 300, and 400 rpm. It was accompanied by shifting the position of the core of circulation flow away from impeller discharge stream and approached the front of the tank wall. The intensity of fluid flow in the vessel increase with the increase of the impeller diameter from d=3 cm to d=4 cm.

  4. Fractionation of SWNT/nucleic acid complexes by agarose gel electrophoresis

    International Nuclear Information System (INIS)

    Vetcher, Alexandre A; Srinivasan, Srimeenakshi; Vetcher, Ivan A; Abramov, Semen M; Kozlov, Mikhail; Baughman, Ray H; Levene, Stephen D

    2006-01-01

    We show that aqueous dispersions of single-walled carbon nanotubes (SWNTs), prepared with the aid of nucleic acids (NAs) such as RNA or DNA, can be separated into fractions using agarose gel electrophoresis. In a DC electric field, SWNT/NA complexes migrate in the gel in the direction of positive potential to form well-defined bands. Raman spectroscopy as a function of band position shows that nanotubes having different spectroscopic properties possess different electrophoretic mobilities. The migration patterns for SWNT/RNA and SWNT/DNA complexes differ. Parallel elution of the SWNT/NA complexes from the gel during electrophoresis and subsequent characterization by AFM reveals differences in nanotube diameter, length and curvature. The results suggest that fractionation of nanotubes can be achieved by this procedure. We discuss factors affecting the mobility of the nanotube complexes and propose analytical applications of this technique

  5. Fractionation of SWNT/nucleic acid complexes by agarose gel electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Vetcher, Alexandre A [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Srinivasan, Srimeenakshi [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Vetcher, Ivan A [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States); Abramov, Semen M [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Kozlov, Mikhail [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Baughman, Ray H [NanoTech Institute, University of Texas at Dallas, Richardson, TX 75083 (United States); Levene, Stephen D [Institute of Biomedical Sciences and Technology and Department of Molecular and Cell Biology, University of Texas at Dallas, Richardson, TX 75083 (United States)

    2006-08-28

    We show that aqueous dispersions of single-walled carbon nanotubes (SWNTs), prepared with the aid of nucleic acids (NAs) such as RNA or DNA, can be separated into fractions using agarose gel electrophoresis. In a DC electric field, SWNT/NA complexes migrate in the gel in the direction of positive potential to form well-defined bands. Raman spectroscopy as a function of band position shows that nanotubes having different spectroscopic properties possess different electrophoretic mobilities. The migration patterns for SWNT/RNA and SWNT/DNA complexes differ. Parallel elution of the SWNT/NA complexes from the gel during electrophoresis and subsequent characterization by AFM reveals differences in nanotube diameter, length and curvature. The results suggest that fractionation of nanotubes can be achieved by this procedure. We discuss factors affecting the mobility of the nanotube complexes and propose analytical applications of this technique.

  6. Electronic transport behavior of diameter-graded Ag nanowires

    International Nuclear Information System (INIS)

    Wang Xuewei; Yuan Zhihao

    2010-01-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  7. Electronic transport behavior of diameter-graded Ag nanowires

    Science.gov (United States)

    Wang, Xue Wei; Yuan, Zhi Hao

    2010-05-01

    Ag nanowires with a graded diameter in anodic aluminum oxide (AAO) membranes were fabricated by the direct-current electrodeposition. The Ag nanowires have a graded-change in diameter from 8 to 32 nm, which is matched with the graded-change of the AAO pore diameter. Electronic transport measurements show that there is a transport behavior similar to that of a metal-semiconductor junction along the axial direction in the diameter-graded Ag nanowires. Such a novel homogeneous nanojunction will be of great fundamental and practical significance.

  8. Lysosome Transport as a Function of Lysosome Diameter

    Science.gov (United States)

    Bandyopadhyay, Debjyoti; Cyphersmith, Austin; Zapata, Jairo A.; Kim, Y. Joseph; Payne, Christine K.

    2014-01-01

    Lysosomes are membrane-bound organelles responsible for the transport and degradation of intracellular and extracellular cargo. The intracellular motion of lysosomes is both diffusive and active, mediated by motor proteins moving lysosomes along microtubules. We sought to determine how lysosome diameter influences lysosome transport. We used osmotic swelling to double the diameter of lysosomes, creating a population of enlarged lysosomes. This allowed us to directly examine the intracellular transport of the same organelle as a function of diameter. Lysosome transport was measured using live cell fluorescence microscopy and single particle tracking. We find, as expected, the diffusive component of intracellular transport is decreased proportional to the increased lysosome diameter. Active transport of the enlarged lysosomes is not affected by the increased lysosome diameter. PMID:24497985

  9. Optical probe for porosity defect detection on inner diameter surfaces of machined bores

    Science.gov (United States)

    Kulkarni, Ojas P.; Islam, Mohammed N.; Terry, Fred L.

    2010-12-01

    We demonstrate an optical probe for detection of porosity inside spool bores of a transmission valve body with diameters down to 5 mm. The probe consists of a graded-index relay rod that focuses a laser beam spot onto the inner surface of the bore. Detectors, placed in the specular and grazing directions with respect to the incident beam, measure the change in scattered intensity when a surface defect is encountered. Based on the scattering signatures in the two directions, the system can also validate the depth of the defect and distinguish porosity from bump-type defects coming out of the metal surface. The system can detect porosity down to a 50-μm lateral dimension and ~40 μm in depth with >3-dB contrast over the background intensity fluctuations. Porosity detection systems currently use manual inspection techniques on the plant floor, and the demonstrated probe provides a noncontact technique that can help automotive manufacturers meet high-quality standards during production.

  10. Direct measurement of the energy spectrum of an intense proton beam

    International Nuclear Information System (INIS)

    Leeper, R.J.; Lee, J.R.; Kissel, L.; Johnson, D.J.; Stygar, W.A.; Hebron, D.E.; Roose, L.D.

    1983-01-01

    A time-resolved magnetic spectrometer has been used to measure the energy spectrum of an intense (0.5 TW/cm 2 ) proton beam. A thin (2400 A) gold foil placed at the focus of an ion diode Rutherford scattered protons by 90 0 into the spectrometer, reducing the beam intensity to a level suitable for magnetic analysis. The scattered beam was collimated by two 1 mm diameter apertures separated by 12.3 cm. The collimated protons were deflected in a 12.7 cm diameter, 6.65 Kg samarium-cobalt permanent magnet. The deflected protons were recorded simultaneously on CR-39 and eight 1 mm 2 by 35 μm thick PIN diodes. A Monte Carlo computer code was used to calculate the sensitivity and resolution of the spectrometer. Data taken on Proto-I show a 150 keV to 250 keV wide proton energy spectrum at each instant in time

  11. Influence of the inner diameters of capillary on the Z-Pinch plasma of the capillary discharge soft X-ray laser

    International Nuclear Information System (INIS)

    Jiang, Shan; Zhao, Yong-peng; Cui, Huai-yu; Li, Lian-bo; Ding, Yu-jie; Zhang, Wen-hong; Li, Wei

    2015-01-01

    In this paper, the effects of inner diameters on the Z-pinch plasma of capillary discharge soft X-ray laser were investigated with the 3.2 mm and 4.0 mm inner diameter alumina capillaries. The intensities of the laser emitted from the 3.2 mm and 4.0 mm inner diameter alumina capillaries were measured under different initial pressures. To understand the underlying physics of the experimental measurements, the Z-pinch plasma simulations had been conducted with a one-dimensional cylindrical symmetry Lagrangian magneto-hydrodynamics (MHD) code. The parametric studies of Z-pinch plasma, such as the electron temperature, the electron density and the Ne-like Ar ion density, were performed with the MHD code. With the experimental and the simulated results, the discussions had been conducted on the Z-pinch plasma of Ne-like Ar 46.9 nm laser with the 3.2 mm and 4.0 mm inner diameter alumina capillaries. The analysis had been made on the difference of the gain coefficients under the optimum pressures with both capillaries. Then, the effects of inner diameters on the optimum pressure and the pressure domain were analyzed. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. AKTIVITAS ANTIBAKTERI FRAKSI-FRAKSI EKSTRAK SIRIH HIJAU (Piper betle Linn TERHADAP PATOGEN PANGAN [Antibacterial Activity of Fractionated Green Sirih (Piper betle Linn Extract Against Food Pathogenic Bacteria

    Directory of Open Access Journals (Sweden)

    Maggy T. Suhartono

    2012-12-01

    Full Text Available Fractionation of green sirih (Piper betle Linn extract by chromatography colom using the mixture of several solvents i.e. chloroform, ethanol and acetic acid (4:1:1 resulted in 17 fractions. All fractions showed antibacterial activities but only 2 fractions (fraction 3 and fraction 4 showed the highest inhibition towards the six tested bacteria Escherichia coli, Salmonella Typhimurium, Pseudomonas aeruginosa, Staphylococcus aureus, Bacillus cereus and Listeria monocytogenes. Among the tested bacteria, all fractions of green sirih extracts showed the most effective inhibition against, Salmonella Typhimurium with inhibition zone diameters ranging from 10 mm to 26 mm. Identification using GC-MS found that fraction 3 and fraction 4 contained chavicol; dodecanoic acid, myristic, palmitic and oleic acid.

  13. Climatology and Interannual Variability of Quasi-Global Intense Precipitation Using Satellite Observations

    Science.gov (United States)

    Ricko, Martina; Adler, Robert F.; Huffman, George J.

    2016-01-01

    Climatology and variations of recent mean and intense precipitation over a near-global (50 deg. S 50 deg. N) domain on a monthly and annual time scale are analyzed. Data used to derive daily precipitation to examine the effects of spatial and temporal coverage of intense precipitation are from the current Tropical Rainfall Measuring Mission (TRMM) Multisatellite Precipitation Analysis (TMPA) 3B42 version 7 precipitation product, with high spatial and temporal resolution during 1998 - 2013. Intense precipitation is defined by several different parameters, such as a 95th percentile threshold of daily precipitation, a mean precipitation that exceeds that percentile, or a fixed threshold of daily precipitation value [e.g., 25 and 50 mm day(exp -1)]. All parameters are used to identify the main characteristics of spatial and temporal variation of intense precipitation. High correlations between examined parameters are observed, especially between climatological monthly mean precipitation and intense precipitation, over both tropical land and ocean. Among the various parameters examined, the one best characterizing intense rainfall is a fraction of daily precipitation Great than or equal to 25 mm day(exp. -1), defined as a ratio between the intense precipitation above the used threshold and mean precipitation. Regions that experience an increase in mean precipitation likely experience a similar increase in intense precipitation, especially during the El Nino Southern Oscillation (ENSO) events. Improved knowledge of this intense precipitation regime and its strong connection to mean precipitation given by the fraction parameter can be used for monitoring of intense rainfall and its intensity on a global to regional scale.

  14. On-line ultrasonic inside-diameter control system for Zircaloy

    International Nuclear Information System (INIS)

    Tanaka, Y.; Fujii, N.; Komatsu, M.; Kubota, H.

    1984-01-01

    An ultrasonic inside-diameter (ID) control system was used during the final etching process for producing Zircaloy nuclear fuel cladding tubes. This results in establishing automatic inside-diameter control during etching with an automatic etching system. In this system, the inside-diameter at the center point in the length of each tube is continuously measured with the ultrasonic inside-diameter measuring equipment during the etching process and the etching is automatically stopped by a signal from the control equipment when the inside-diameter reaches the target value. This made the final etching process economical and suitable for large-scale production, having an equal or better level at the inside-diameter of tubes etched with this system than those made by a process controlled by an air-micrometer

  15. Magnesium isotope fractionation in bacterial mediated carbonate precipitation experiments

    Science.gov (United States)

    Parkinson, I. J.; Pearce, C. R.; Polacskek, T.; Cockell, C.; Hammond, S. J.

    2012-12-01

    Magnesium is an essential component of life, with pivotal roles in the generation of cellular energy as well as in plant chlorophyll [1]. The bio-geochemical cycling of Mg is associated with mass dependant fractionation (MDF) of the three stable Mg isotopes [1]. The largest MDF of Mg isotopes has been recorded in carbonates, with foraminiferal tests having δ26Mg compositions up to 5 ‰ lighter than modern seawater [2]. Magnesium isotopes may also be fractionated during bacterially mediated carbonate precipitation and such carbonates are known to have formed in both modern and ancient Earth surface environments [3, 4], with cyanobacteria having a dominant role in carbonate formation during the Archean. In this study, we aim to better constrain the extent to which Mg isotope fractionation occurs during cellular processes, and to identify when, and how, this signal is transferred to carbonates. To this end we have undertaken biologically-mediated carbonate precipitation experiments that were performed in artificial seawater, but with the molar Mg/Ca ratio set to 0.6 and with the solution spiked with 0.4% yeast extract. The bacterial strain used was marine isolate Halomonas sp. (gram-negative). Experiments were run in the dark at 21 degree C for two to three months and produced carbonate spheres of various sizes up to 300 μm in diameter, but with the majority have diameters of ~100 μm. Control experiments run in sterile controls (`empty` medium without bacteria) yielded no precipitates, indicating a bacterial control on the precipitation. The carbonate spheres are produced are amenable to SEM, EMP and Mg isotopic analysis by MC-ICP-MS. Our new data will shed light on tracing bacterial signals in carbonates from the geological record. [1] Young & Galy (2004). Rev. Min. Geochem. 55, p197-230. [2] Pogge von Strandmann (2008). Geochem. Geophys. Geosys. 9 DOI:10.1029/2008GC002209. [3] Castanier, et al. (1999). Sed. Geol. 126, 9-23. [4] Cacchio, et al. (2003

  16. Raman intensity and vibrational modes of armchair CNTs

    Science.gov (United States)

    Hur, Jaewoong; Stuart, Steven J.

    2017-07-01

    Raman intensity changes and frequency patterns have been studied using the various armchair (n, n) to understand the variations of bond polarizability, in regard to changing diameters, lengths, and the number of atoms in the (n, n). The Raman intensity trends of the (n, n) are validated by those of Cn isomers. For frequency trends, similar frequency patterns and frequency inward shifts for the (n, n) are characterized. Also, VDOS trends of the (n, n) expressing Raman modes are interpreted. The decomposition of vibrational modes in the (n, n) into radial, longitudinal, and tangential mode is beneficially used to recognize the distinct characteristics of vibrational modes.

  17. Measurements of Void Fractions for Flow of Boiling Heavy Water in a Vertical Round Duct

    Energy Technology Data Exchange (ETDEWEB)

    Rouhani, S Z; Becker, K M

    1963-09-15

    The present report deals with measurements of void fractions for flow of boiling heavy water in a vertical round duct with 6.10 mm inner diameter and a heated length of 2500 mm. The following ranges of variables were studied and 149 void fraction measurements were obtained. Pressure 7 < p < 60 bars; Steam quality 0 < x < 0.38; Surface heat flux 38 < q/A < 120 W/cm{sup 2}; Mass velocity 650 < m'/F < 2050 kg/m/s; Void fraction 0. 24 < {alpha} < 0.88. The measurements were performed by means of a method, which is based on the ({gamma}, n) reaction, occurring when heavy water is irradiated by gamma rays. The results are presented in diagrams, where the void fractions and the slip ratios are plotted against the steam quality with the pressure as a parameter. The data have been correlated by curves, and the scatter of the data around the curves is less than {+-} 5 per cent.

  18. Fractionated Stereotactic Radiotherapy in the Treatment of Vestibular Schwannoma (Acoustic Neuroma): Predicting the Risk of Hydrocephalus

    International Nuclear Information System (INIS)

    Powell, Ceri; Micallef, Caroline; Gonsalves, Adam; Wharram, Bev; Ashley, Sue; Brada, Michael

    2011-01-01

    Purpose: To determine the incidence and predictive factors for the development of hydrocephalus in patients with acoustic neuromas (AN) treated with fractionated stereotactic radiotherapy. Patients and Methods: Seventy-two patients with AN were treated with fractionated stereotactic radiotherapy between 1998 and 2007 (45-50 Gy in 25-30 fractions over 5 to 6 weeks). The pretreatment MRI scan was assessed for tumor characteristics and anatomic distortion independently of subsequent outcome and correlated with the risk of hydrocephalus. Results: At a median follow-up of 49 months (range, 1-120 months), 5-year event-free survival was 95%. Eight patients (11%) developed hydrocephalus within 19 months of radiotherapy, which was successfully treated. On univariate analysis, pretreatment factors predictive of hydrocephalus were maximum diameter (p = 0.005), proximity to midline (p = 0.009), displacement of the fourth ventricle (p = 0.02), partial effacement of the fourth ventricle (p < 0.001), contact with the medulla (p = 0.005), and more brainstem structures (p = 0.004). On multivariate analysis, after adjusting for fourth ventricular effacement, no other variables remained independently associated with hydrocephalus formation. Conclusions: Fractionated stereotactic radiotherapy results in excellent tumor control of AN, albeit with a risk of developing hydrocephalus. Patients at high risk, identified as those with larger tumors with partial effacement of the fourth ventricle before treatment, should be monitored more closely during follow-up. It would also be preferable to offer treatment to patients with progressive AN while the risk of hydrocephalus is low, before the development of marked distortion of fourth ventricle before tumor diameter significantly exceeds 2 cm.

  19. Fractional vector calculus for fractional advection dispersion

    Science.gov (United States)

    Meerschaert, Mark M.; Mortensen, Jeff; Wheatcraft, Stephen W.

    2006-07-01

    We develop the basic tools of fractional vector calculus including a fractional derivative version of the gradient, divergence, and curl, and a fractional divergence theorem and Stokes theorem. These basic tools are then applied to provide a physical explanation for the fractional advection-dispersion equation for flow in heterogeneous porous media.

  20. Power filtering of n-th order in the fractional Fourier domain

    NARCIS (Netherlands)

    Alieva, T.; Calvo, M.L.; Bastiaans, M.J.

    2002-01-01

    The main properties of the power filtering operation in the fractional Fourier domain and its relationship to the differentiation operation are considered. The application of linear power filtering for solving the phase retrieval problem from only intensity distributions is proposed. The optical

  1. Changes in tumor cell response due to prolonged dose delivery times in fractionated radiation therapy

    International Nuclear Information System (INIS)

    Paganetti, Harald

    2005-01-01

    Purpose: Dynamic radiation therapy, such as intensity-modulated radiation therapy, delivers more complex treatment fields than conventional techniques. The increased complexity causes longer dose delivery times for each fraction. The cellular damage after a full treatment may depend on the dose rate, because sublethal radiation damage can be repaired more efficiently during prolonged dose delivery. The goal of this study was to investigate the significance of this effect in fractionated radiation therapy. Methods and Materials: The lethal/potentially lethal model was used to calculate lesion induction rates for repairable and nonrepairable lesions. Dose rate effects were analyzed for 9 different cell lines (8 human tumor xenografts and a C3H10T1/2 cell line). The effects of single-fraction as well as fractionated irradiation for different dose rates were studied. Results: Significant differences can be seen for dose rates lower than about 0.1 Gy/min for all cell lines considered. For 60 Gy delivered in 30 fractions, the equivalent dose is reduced by between 1.3% and 12% comparing 2 Gy delivery over 30 min per fraction with 2 Gy delivery over 1 min per fraction. The effect is higher for higher doses per fraction. Furthermore, the results show that dose rate effects do not show a simple correlation with the α/β ratio for ratios between 3 Gy and 31 Gy. Conclusions: If the total dose delivery time for a treatment fraction in radiation therapy increases to about 20 min, a correction for dose rate effects may have to be considered in treatment planning. Adjustments in effective dose may be necessary when comparing intensity-modulated radiation therapy with conventional treatment plans

  2. Long Range Dependence Prognostics for Bearing Vibration Intensity Chaotic Time Series

    Directory of Open Access Journals (Sweden)

    Qing Li

    2016-01-01

    Full Text Available According to the chaotic features and typical fractional order characteristics of the bearing vibration intensity time series, a forecasting approach based on long range dependence (LRD is proposed. In order to reveal the internal chaotic properties, vibration intensity time series are reconstructed based on chaos theory in phase-space, the delay time is computed with C-C method and the optimal embedding dimension and saturated correlation dimension are calculated via the Grassberger–Procaccia (G-P method, respectively, so that the chaotic characteristics of vibration intensity time series can be jointly determined by the largest Lyapunov exponent and phase plane trajectory of vibration intensity time series, meanwhile, the largest Lyapunov exponent is calculated by the Wolf method and phase plane trajectory is illustrated using Duffing-Holmes Oscillator (DHO. The Hurst exponent and long range dependence prediction method are proposed to verify the typical fractional order features and improve the prediction accuracy of bearing vibration intensity time series, respectively. Experience shows that the vibration intensity time series have chaotic properties and the LRD prediction method is better than the other prediction methods (largest Lyapunov, auto regressive moving average (ARMA and BP neural network (BPNN model in prediction accuracy and prediction performance, which provides a new approach for running tendency predictions for rotating machinery and provide some guidance value to the engineering practice.

  3. Laser direct writing using submicron-diameter fibers.

    Science.gov (United States)

    Tian, Feng; Yang, Guoguang; Bai, Jian; Xu, Jianfeng; Hou, Changlun; Liang, Yiyong; Wang, Kaiwei

    2009-10-26

    In this paper, a novel direct writing technique using submicron-diameter fibers is presented. The submicron-diameter fiber probe serves as a tightly confined point source and it adopts micro touch mode in the process of writing. The energy distribution of direct writing model is analyzed by Three-Dimension Finite-Difference Time-Domain method. Experiments demonstrate that submicron-diameter fiber direct writing has some advantages: simple process, 350-nm-resolution (lower than 442-nm-wavelength), large writing area, and controllable width of lines. In addition, by altering writing direction of lines, complex submicron patterns can be fabricated.

  4. Costs of slurry separation technologies and alternative use of the solid fraction for biogas production or burning

    DEFF Research Database (Denmark)

    Jacobsen, Brian H.

    2011-01-01

    Separation is an option when livestock are produced in livestock intensive areas producing a surplus of nutrients. Separation of the slurry into a liquid nitrogen rich fraction and a more solid phosphorus rich fraction, which is exported away from the farm, may alleviate this problem. Separation...

  5. Supersonic acoustic intensity with statistically optimized near-field acoustic holography

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren; Jacobsen, Finn

    2011-01-01

    The concept of supersonic acoustic intensity was introduced some years ago for estimating the fraction of the flow of energy radiated by a source that propagates to the far field. It differs from the usual (active) intensity by excluding the near-field energy resulting from evanescent waves...... to the information provided by the near-field acoustic holography technique. This study proposes a version of the supersonic acoustic intensity applied to statistically optimized near-field acoustic holography (SONAH). The theory, numerical results and an experimental study are presented. The possibility of using...

  6. Subchannel flow analysis in Candu and ACR pressure tubes with radial and axial diameter variation

    Energy Technology Data Exchange (ETDEWEB)

    Catana, A.; Prodea, L. [RAAN, Institute for Nuclear Research, Arges (Romania); Danila, N.; Prisecaru, I.; Dupleac, D. [Bucharest Univ. Politehnica(Romania)

    2007-07-01

    The Candu (Canada Deuterium Uranium) and ACR (Advanced Candu Reactor) are pressure tubes (PT) heavy water moderated reactors. Candu are heavy water and ACR are light water cooled reactors. The pressure tube is filled with 12 bundles, each consisting of 37 respectively 43 fuel rods. One Candu reactor is in operation at Cernavoda, Romania since 1996. ACR is a proposed advanced Candu. PT diameter variation has a significant impact on the thermal-hydraulic parameters. Almost all thermal-hydraulic parameters change, but some of them have a greater significance. In this work we have considered a set of radial and axial PT diameter variations both for Candu-600 and ACR-700 reactors using various types of fuel bundles. We can conclude the following: 1) some thermal-hydraulic parameters are significantly influenced: critical heat flux (CHF), pressure drop, or void fraction; 2) the most significant parameter CHF is worsening which reduces the safety margin; 3) some fuel types present a better thermal-hydraulic behavior; and 4) fuel bundles with fresh fuel or low burnup have a worse thermal-hydraulic behaviour than those at average burn-up.

  7. Subchannel flow analysis in Candu and ACR pressure tubes with radial and axial diameter variation

    International Nuclear Information System (INIS)

    Catana, A.; Prodea, L.; Danila, N.; Prisecaru, I.; Dupleac, D.

    2007-01-01

    The Candu (Canada Deuterium Uranium) and ACR (Advanced Candu Reactor) are pressure tubes (PT) heavy water moderated reactors. Candu are heavy water and ACR are light water cooled reactors. The pressure tube is filled with 12 bundles, each consisting of 37 respectively 43 fuel rods. One Candu reactor is in operation at Cernavoda, Romania since 1996. ACR is a proposed advanced Candu. PT diameter variation has a significant impact on the thermal-hydraulic parameters. Almost all thermal-hydraulic parameters change, but some of them have a greater significance. In this work we have considered a set of radial and axial PT diameter variations both for Candu-600 and ACR-700 reactors using various types of fuel bundles. We can conclude the following: 1) some thermal-hydraulic parameters are significantly influenced: critical heat flux (CHF), pressure drop, or void fraction; 2) the most significant parameter CHF is worsening which reduces the safety margin; 3) some fuel types present a better thermal-hydraulic behavior; and 4) fuel bundles with fresh fuel or low burnup have a worse thermal-hydraulic behaviour than those at average burn-up

  8. AIP1OGREN: Aerosol Observing Station Intensive Properties Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Koontz, Annette [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Flynn, Connor [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-09-15

    The aip1ogren value-added product (VAP) computes several aerosol intensive properties. It requires as input calibrated, corrected, aerosol extensive properties (scattering and absorption coefficients, primarily) from the Aerosol Observing Station (AOS). Aerosol extensive properties depend on both the nature of the aerosol and the amount of the aerosol. We compute several properties as relationships between the various extensive properties. These intensive properties are independent of aerosol amount and instead relate to intrinsic properties of the aerosol itself. Along with the original extensive properties we report aerosol single-scattering albedo, hemispheric backscatter fraction, asymmetry parameter, and Ångström exponent for scattering and absorption with one-minute averaging. An hourly averaged file is produced from the 1-minute files that includes all extensive and intensive properties as well as submicron scattering and submicron absorption fractions. Finally, in both the minutely and hourly files the aerosol radiative forcing efficiency is provided.

  9. Kinetics and tissue repair process following fractional bipolar radiofrequency treatment.

    Science.gov (United States)

    Kokolakis, G; von Eichel, L; Ulrich, M; Lademann, J; Zuberbier, T; Hofmann, M A

    2018-05-15

    Fractionated radiofrequency (RF) tissue tightening is an alternative method to fractionated laser treatment of skin wrinkling, laxity and acne scars, with reduced risk of scarring or persistent pigmentation. The aim of this study was to evaluate and quantify the wound healing process after RF treatment. 12 patients were treated with a 64-pin fractional bipolar RF device with 60 mJ/pin applied energy. Confocal laser scanning microscopy (CLSM) examination was performed on day 1, day 2, day 7 and day 14 after treatment. Clinical wound healing process was measured and expressed as a percentage. All patients developed erythema, mild edema and crusts at the treated areas. Two weeks after treatment clinical symptoms resolved. During ablation patients reported moderate pain. Directly after ablation microscopic ablation zones could be detected in CLSM. Measurement of MAZ at epidermis, dermo-epidermal junction and papilary dermis showed a constant diameter until two weeks after treatment. Re-epithelization of the MAZ could be detected already 1 week after treatment. However, 2 weeks after ablation the honeycomb pattern of the epidermis was not yet completely restored. Bipolar fractionated RF treatment demonstrates clinically a rapid wound healing response. The subepidermal remodelling process still ongoing after 14 days, showing new granulation tissue. Therefore, treatment intervals of at least 14 days should be recommended to allow completion of the remodelling process.

  10. Slug Flow Analysis in Vertical Large Diameter Pipes

    Science.gov (United States)

    Roullier, David

    linear trends at low mixture velocities and non-linear behaviors at high mixture velocities. The translational velocity trends seem to be related to the flow-pattern observed, namely to the ability of the gas to flow through the liquid structures. A simplified Taylor bubble stability model is proposed. The model allows to estimate under which conditions Taylor bubbles disappear, properly accounting for the diameter effect and velocity effect observed experimentally. In addition, annular flow distribution coefficient relating true holdup to centerline holdup in vertical flow is proposed. The proposed coefficient defines the tendency of the liquid to remain near the walls. This coefficient increases linearly with the void fraction.

  11. The transverse diameter of the chest on routine radiographs reliably estimates gestational age and weight in premature infants

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, Kelly R. [University of Minnesota, Department of Radiology, Minneapolis, MN (United States); Zhang, Lei [University of Minnesota, Biostatistical Design and Analysis Center, Minneapolis, MN (United States); Seidel, Frank G. [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States)

    2015-08-15

    Prior to digital radiography it was possible for a radiologist to easily estimate the size of a patient on an analog film. Because variable magnification may be applied at the time of processing an image, it is now more difficult to visually estimate an infant's size on the monitor. Since gestational age and weight significantly impact the differential diagnosis of neonatal diseases and determine the expected size of kidneys or appearance of the brain by MRI or US, this information is useful to a pediatric radiologist. Although this information may be present in the electronic medical record, it is frequently not readily available to the pediatric radiologist at the time of image interpretation. To determine if there was a correlation between gestational age and weight of a premature infant with their transverse chest diameter (rib to rib) on admission chest radiographs. This retrospective study was approved by the institutional review board, which waived informed consent. The maximum transverse chest diameter outer rib to outer rib was measured on admission portable chest radiographs of 464 patients admitted to the neonatal intensive care unit (NICU) during the 2010 calendar year. Regression analysis was used to investigate the association between chest diameter and gestational age/birth weight. Quadratic term of chest diameter was used in the regression model. Chest diameter was statistically significantly associated with both gestational age (P < 0.0001) and birth weight (P < 0.0001). An infant's gestational age and birth weight can be reliably estimated by comparing a simple measurement of the transverse chest diameter on digital chest radiograph with the tables and graphs in our study. (orig.)

  12. Normal ureteral diameter in infancy and childhood

    International Nuclear Information System (INIS)

    Hellstroem, M.; Hjaelmaas, K.; Jacobsson, B.; Jodal, U.; Oden, A.; Oestra Sjukhuset, Goeteborg; Oestra Sjukhuset, Goeteborg; Goeteborg Univ.

    1985-01-01

    Ureteral diameters were estimated on films from intravenous urography in 194 children (100 boys and 94 girls) aged 0-16 years. Children with signs of urinary tract infection, calculi, obstruction, duplication or malformation were excluded. Films obtained without abdominal compression were used for measurements, including only ureters visualized over 50 per cent of their lengths. A good correlation was demonstrated between ureteral diameter and age and between ureteral diameter and the length of a segment of the lumbar spine. The widest part of the ureter was most often located just above the crossing of the iliac vessels. The right ureter was slightly wider than the left one. No difference between boys and girls was noted. The results are in good agreement with those of others obtained at autopsy. Bearing in mind the possible physiologic variations, it would seem that measuring the ureteral diameter can be of value for a more objective differentiation between dilated and non-dilated ureters. (orig.)

  13. Fractional vector calculus and fractional Maxwell's equations

    International Nuclear Information System (INIS)

    Tarasov, Vasily E.

    2008-01-01

    The theory of derivatives and integrals of non-integer order goes back to Leibniz, Liouville, Grunwald, Letnikov and Riemann. The history of fractional vector calculus (FVC) has only 10 years. The main approaches to formulate a FVC, which are used in the physics during the past few years, will be briefly described in this paper. We solve some problems of consistent formulations of FVC by using a fractional generalization of the Fundamental Theorem of Calculus. We define the differential and integral vector operations. The fractional Green's, Stokes' and Gauss's theorems are formulated. The proofs of these theorems are realized for simplest regions. A fractional generalization of exterior differential calculus of differential forms is discussed. Fractional nonlocal Maxwell's equations and the corresponding fractional wave equations are considered

  14. Void fraction and incipient point of boiling during the subcooled nucleate flow boiling of water

    International Nuclear Information System (INIS)

    Unal, H.C.

    1977-01-01

    Void fraction has been determined with high-speed photography for subcooled nucleate flow boiling of water. The data obtained and the data of various investigators for adiabatic flow of stream-water mixtures and saturated bulk boiling of water have yielded a correlation which covers the following conditions: geometry: vertically orientated circular tubes, rectangular channels and annuli; pressure: 2 to 15.9 MN/m 2 ; mass velocity: 388 to 3500 kg/m 2 s; void fraction: 0 to 99%; hydraulic diameter: 0.0047 to 0.0343 m; heat flux: adiabatic and 0.01 to 2.0 MW/m 2 . The accuracy of the correlation is estimated to be 12.5%. The value of the so-called distribution (or flow) parameter has been experimentally determined and found to be equal to 1 for a vertical small-diameter circular tube. The incipient point of boiling for subcooled nucleate flow boiling of water has been determined with high-speed photography. The data obtained and the data available in the literature have yielded a correlation which covers the following conditions: geometry: plate, circular tube and inner tube-heated, outer tube-heated and inner - and outer tube heated annulus; pressure: 0.15 to 15.9 MN/m 2 ; mass velocity: 470 to 17355 kg/m 2 s; hydraulic diameter: 0.00239 to 0.032 m; heat flux: 0.13 to 9.8 MW/m 2 ; subcooling: 2.6 to 108 K; material of heating surface: stainless steel and nickel. The accuracy of the correlation is estimated to be 27.5%. Maximum bubble diameters have been measured at the incipient point of boiling. These data and the data from literature have been correlated for the pressure range of 0.1 to 15.9 MN/m 2 . (author)

  15. Nonhomogeneous fractional Poisson processes

    International Nuclear Information System (INIS)

    Wang Xiaotian; Zhang Shiying; Fan Shen

    2007-01-01

    In this paper, we propose a class of non-Gaussian stationary increment processes, named nonhomogeneous fractional Poisson processes W H (j) (t), which permit the study of the effects of long-range dependance in a large number of fields including quantum physics and finance. The processes W H (j) (t) are self-similar in a wide sense, exhibit more fatter tail than Gaussian processes, and converge to the Gaussian processes in distribution in some cases. In addition, we also show that the intensity function λ(t) strongly influences the existence of the highest finite moment of W H (j) (t) and the behaviour of the tail probability of W H (j) (t)

  16. Utility of Cardiovascular Magnetic Resonance-Derived Wave Intensity Analysis As a Marker of Ventricular Function in Children with Heart Failure and Normal Ejection Fraction.

    Science.gov (United States)

    Ntsinjana, Hopewell N; Chung, Robin; Ciliberti, Paolo; Muthurangu, Vivek; Schievano, Silvia; Marek, Jan; Parker, Kim H; Taylor, Andrew M; Biglino, Giovanni

    2017-01-01

    This study sought to explore the diagnostic insight of cardiovascular magnetic resonance (CMR)-derived wave intensity analysis to better study systolic dysfunction in young patients with chronic diastolic dysfunction and preserved ejection fraction (EF), comparing it against other echocardiographic and CMR parameters. Evaluating systolic and diastolic dysfunctions in children is challenging, and a gold standard method is currently lacking. Patients with presumed diastolic dysfunction [ n  = 18; nine aortic stenosis (AS), five hypertrophic, and four restrictive cardiomyopathies] were compared with age-matched control subjects ( n  = 18). All patients had no mitral or aortic incompetence, significant AS, or reduced systolic EF. E / A ratio, E / E ' ratio, deceleration time, and isovolumetric contraction time were assessed on echocardiography, and indexed left atrial volume (LAVi), acceleration time (AT), ejection time (ET), and wave intensity analyses were calculated from CMR. The latter was performed on CMR phase-contrast flow sequences, defining a ratio of the peaks of the early systolic forward compression wave (FCW) and the end-systolic forward expansion wave (FEW). Significant differences between patients and controls were seen in the E / E ' ratio (8.7 ± 4.0 vs. 5.1 ± 1.3, p  = 0.001) and FCW/FEW ratio (2.5 ± 1.6 vs. 7.2 ± 4.2 × 10 -5 m/s, p  wave intensity-derived ratio summarizing systolic and diastolic function could provide insight into ventricular function in children, on top of CMR and echocardiography, and it was here able to identify an element of ventricular dysfunction with preserved EF in a small group of young patients.

  17. Fractional Number Operator and Associated Fractional Diffusion Equations

    Science.gov (United States)

    Rguigui, Hafedh

    2018-03-01

    In this paper, we study the fractional number operator as an analog of the finite-dimensional fractional Laplacian. An important relation with the Ornstein-Uhlenbeck process is given. Using a semigroup approach, the solution of the Cauchy problem associated to the fractional number operator is presented. By means of the Mittag-Leffler function and the Laplace transform, we give the solution of the Caputo time fractional diffusion equation and Riemann-Liouville time fractional diffusion equation in infinite dimensions associated to the fractional number operator.

  18. Distribution and Fractional Composition of Petroleum Hydrocarbons in Roadside Soils

    Directory of Open Access Journals (Sweden)

    Larysa Mykhailova

    2013-01-01

    Full Text Available Total petroleum hydrocarbon (TPH concentrations and their fractional composition (medium fraction: n-alkane chain-length C15 to C27, heavy fraction: >C27 were determined at distances from 1 to 60 m from roads and at soil depths from 0.5 to 15 cm. The traffic intensities were up to 25000 vehicles per day. Soil TPH concentrations were highest within 15 m distance (665 and 3198 mg kg−1 at the windward and leeward sides, resp., followed by a rapid drop to background values beyond (196 and 115 mg kg−1 in 60 m distance at the windward and leeward sides, resp.. The data variability was lowest at distances of 1 m and highest within tree plantations at distances of 15 m from the road. The TPH concentrations decreased with depth but were significantly higher than the background at all depths investigated. A principal component analysis revealed a positive relation between the medium-to-heavy fraction ratio and soil depth. A fractional differentiation of hydrocarbons with distance from road was not observed. It was concluded that the assessment of the potential of hydrocarbons to translocate, accumulate, or degrade in soil necessitates their subdivision into fractions based on their physicochemical and metabolic properties.

  19. Power filtering of nth order in the fractional Fourier domain

    International Nuclear Information System (INIS)

    Alieva, Tatiana; Calvo, Maria Luisa; Bastiaans, Martin J.

    2002-01-01

    The main properties of the power filtering operation in the fractional Fourier domain and its relationship to the differentiation operation are considered. The application of linear power filtering for solving the phase retrieval problem from intensity distributions only is proposed. The optical configuration for the experimental realization of the method is discussed. (author)

  20. Fractional Processes and Fractional-Order Signal Processing Techniques and Applications

    CERN Document Server

    Sheng, Hu; Qiu, TianShuang

    2012-01-01

    Fractional processes are widely found in science, technology and engineering systems. In Fractional Processes and Fractional-order Signal Processing, some complex random signals, characterized by the presence of a heavy-tailed distribution or non-negligible dependence between distant observations (local and long memory), are introduced and examined from the ‘fractional’ perspective using simulation, fractional-order modeling and filtering and realization of fractional-order systems. These fractional-order signal processing (FOSP) techniques are based on fractional calculus, the fractional Fourier transform and fractional lower-order moments. Fractional Processes and Fractional-order Signal Processing: • presents fractional processes of fixed, variable and distributed order studied as the output of fractional-order differential systems; • introduces FOSP techniques and the fractional signals and fractional systems point of view; • details real-world-application examples of FOSP techniques to demonstr...

  1. Noninvasive characterization of fractional photothermolysis induced by ablative and non-ablative lasers with optical coherence tomography

    International Nuclear Information System (INIS)

    Tsai, M T; Chang, F Y; Lee, J D; Fan, C H; Yang, C H; Shen, S C; Yi, J Y

    2013-01-01

    In this study, an optical coherence tomography (OCT) system is implemented for the noninvasive characterization of photothermolysis in human skin induced by ablative fractional lasers (AFLs) and non-ablative fractional lasers (NAFLs). With OCT imaging, microthermal zones (MTZs) induced by fractional lasers can be noninvasively visualized, and the size of induced MTZs can be quantitatively evaluated. According to the OCT results, the center region of the induced MTZ corresponds to weaker backscattered intensity after the AFL exposure as a result of tissue volatilization by photon energy. In contrast, after the NAFL exposure, the skin tissue is damaged and coagulated but not volatilized, which causes the backscattered intensity of the induced MTZ enhanced in the OCT image. To further identify the photothermolysis induced by AFLs or NAFLs, the backscattered intensities of MTZs are compared with those of the untreated tissue from the OCT results. The statistical result shows a clear difference in scattering properties of photothermolysis induced by AFLs and NAFLs. Finally, the induced photodamage at various depths can also be quantitatively evaluated, enabling an investigation of the relationship between the photodamage and the depth. (paper)

  2. Short-term bioavailability of carbon in soil organic matter fractions of different particle sizes and densities in grassland ecosystems.

    Science.gov (United States)

    Breulmann, Marc; Masyutenko, Nina Petrovna; Kogut, Boris Maratovich; Schroll, Reiner; Dörfler, Ulrike; Buscot, François; Schulz, Elke

    2014-11-01

    The quality, stability and availability of organic carbon (OC) in soil organic matter (SOM) can vary widely between differently managed ecosystems. Several approaches have been developed for isolating SOM fractions to examine their ecological roles, but links between the bioavailability of the OC of size-density fractions and soil microbial communities have not been previously explored. Thus, in the presented laboratory study we investigated the potential bioavailability of OC and the structure of associated microbial communities in different particle-size and density fractions of SOM. For this we used samples from four grassland ecosystems with contrasting management intensity regimes and two soil types: a Haplic Cambisol and a typical Chernozem. A combined size-density fractionation protocol was applied to separate clay-associated SOM fractions (CF1, <1 μm; CF2, 1-2 μm) from light SOM fractions (LF1, <1.8 g cm(-3); LF2, 1.8-2.0 g cm(-3)). These fractions were used as carbon sources in a respiration experiment to determine their potential bioavailability. Measured CO2-release was used as an index of substrate accessibility and linked to the soil microbial community structure, as determined by phospholipid fatty acids (PLFA) analysis. Several key factors controlling decomposition processes, and thus the potential bioavailability of OC, were identified: management intensity and the plant community composition of the grasslands (both of which affect the chemical composition and turnover of OC) and specific properties of individual SOM fractions. The PLFA patterns highlighted differences in the composition of microbial communities associated with the examined grasslands, and SOM fractions, providing the first broad insights into their active microbial communities. From observed interactions between abiotic and biotic factors affecting the decomposition of SOM fractions we demonstrate that increasing management intensity could enhance the potential bioavailability of

  3. Diameter Control and Photoluminescence of ZnO Nanorods from Trialkylamines

    Directory of Open Access Journals (Sweden)

    Tamar Andelman

    2007-01-01

    Full Text Available A novel solution method to control the diameter of ZnO nanorods is reported. Small diameter (2-3 nm nanorods were synthesized from trihexylamine, and large diameter (50–80 nm nanorods were synthesized by increasing the alkyl chain length to tridodecylamine. The defect (green emission of the photoluminescence (PL spectra of the nanorods varies with diameter, and can thus be controlled by the diameter control. The small ZnO nanorods have strong green emission, while the large diameter nanorods exhibit a remarkably suppressed green band. We show that this observation supports surface oxygen vacancies as the defect that gives rise to the green emission.

  4. Inferring diameters of spheres and cylinders using interstitial water.

    Science.gov (United States)

    Herrera, Sheryl L; Mercredi, Morgan E; Buist, Richard; Martin, Melanie

    2018-06-04

    Most early methods to infer axon diameter distributions using magnetic resonance imaging (MRI) used single diffusion encoding sequences such as pulsed gradient spin echo (SE) and are thus sensitive to axons of diameters > 5 μm. We previously simulated oscillating gradient (OG) SE sequences for diffusion spectroscopy to study smaller axons including the majority constituting cortical connections. That study suggested the model of constant extra-axonal diffusion breaks down at OG accessible frequencies. In this study we present data from phantoms to test a time-varying interstitial apparent diffusion coefficient. Diffusion spectra were measured in four samples from water packed around beads of diameters 3, 6 and 10 μm; and 151 μm diameter tubes. Surface-to-volume ratios, and diameters were inferred. The bead pore radii estimates were 0.60±0.08 μm, 0.54±0.06 μm and 1.0±0.1 μm corresponding to bead diameters ranging from 2.9±0.4 μm to 5.3±0.7 μm, 2.6±0.3 μm to 4.8±0.6 μm, and 4.9±0.7 μm to 9±1 μm. The tube surface-to-volume ratio estimate was 0.06±0.02 μm -1 corresponding to a tube diameter of 180±70 μm. Interstitial models with OG inferred 3-10 μm bead diameters from 0.54±0.06 μm to 1.0±0.1 μm pore radii and 151 μm tube diameters from 0.06±0.02 μm -1 surface-to-volume ratios.

  5. An improved electrical-conductance sensor for void-fraction measurement in a horizontal pipe

    International Nuclear Information System (INIS)

    Ko, Min Seok; Jemg, Dong Wook; Kim, Sin; Lee, Bo An; Won, Woo Youn; Lee, Yeon Gun

    2015-01-01

    The electrical-impedance method has been widely used for void-fraction measurement in two-phase flow due to its many favorable features. In the impedance method, the response characteristics of the electrical signal heavily depend upon flow pattern, as well as phasic volume. Thus, information on the flow pattern should be given for reliable void-fraction measurement. This study proposes an improved electrical-conductance sensor composed of a three-electrode set of adjacent and opposite electrodes. In the proposed sensor, conductance readings are directly converted into the flow pattern through a specified criterion and are consecutively used to estimate the corresponding void fraction. Since the flow pattern and the void fraction are evaluated by reading conductance measurements, complexity of data processing can be significantly reduced and real-time information provided. Before actual applications, several numerical calculations are performed to optimize electrode and insulator sizes, and optimal design is verified by static experiments. Finally, the proposed sensor is applied for air-water two-phase flow in a horizontal loop with a 40-mm inner diameter and a 5-m length, and its measurement results are compared with those of a wire-mesh sensor

  6. A method for detecting the presence of organic fraction in nucleation mode sized particles

    Directory of Open Access Journals (Sweden)

    P. Vaattovaara

    2005-01-01

    Full Text Available New particle formation and growth has a very important role in many climate processes. However, the overall knowlegde of the chemical composition of atmospheric nucleation mode (particle diameter, d<20 nm and the lower end of Aitken mode particles (d≤50 nm is still insufficient. In this work, we have applied the UFO-TDMA (ultrafine organic tandem differential mobility analyzer method to shed light on the presence of an organic fraction in the nucleation mode size class in different atmospheric environments. The basic principle of the organic fraction detection is based on our laboratory UFO-TDMA measurements with organic and inorganic compounds. Our laboratory measurements indicate that the usefulness of the UFO-TDMA in the field experiments would arise especially from the fact that atmospherically the most relevant inorganic compounds do not grow in subsaturated ethanol vapor, when particle size is 10 nm in diameter and saturation ratio is about 86% or below it. Furthermore, internally mixed particles composed of ammonium bisulfate and sulfuric acid with sulfuric acid mass fraction ≤33% show no growth at 85% saturation ratio. In contrast, 10 nm particles composed of various oxidized organic compounds of atmospheric relevance are able to grow in those conditions. These discoveries indicate that it is possible to detect the presence of organics in atmospheric nucleation mode sized particles using the UFO-TDMA method. In the future, the UFO-TDMA is expected to be an important aid to describe the composition of atmospheric newly-formed particles.

  7. Measuring Electrospun Nanofibre Diameter: a Novel Approach

    International Nuclear Information System (INIS)

    Ziabari, M.; Mottaghitalab, V.; Haghi, A. K.; McGovern, S. T.

    2008-01-01

    A new method based on image analysis for electrospun nanofibre diameter measurement is presented. First, the SEM micrograph of the nanofibre web obtained by electrospinning process is converted to binary image using local thresholding method. In the next step, skeleton and distance transformed image are generated. Then, the intersection points which bring about untrue measurements are identified and removed from the skeleton. Finally, the resulting skeleton and distance transformed image are used to determine fibre diameter. The method is evaluated by a simulated image with known characteristics generated by ?-randomness procedure. The results indicate that this approach is successful in making fast, accurate automated measurements of electrospun fibre diameters. (cross-disciplinary physics and related areas of science and technology)

  8. Taste and chemical characteristics of low molecular weight fractions from tofuyo - Japanese fermented soybean curd.

    Science.gov (United States)

    Lioe, Hanifah Nuryani; Kinjo, Ayano; Yasuda, Shin; Kuba-Miyara, Megumi; Tachibana, Shinjiro; Yasuda, Masaaki

    2018-06-30

    Tofuyo, a Japanese traditional food, is a fermented soybean curd manufactured in Okinawa region. Due to its original cheese-like flavor, the current study was designed to evaluate the sensory and chemical characteristics of three stepwise ultrafiltration fractions, using 10,000, 3000 and 500 Da membranes and further chromatographic fractions from tofuyo. The results showed that umami, sweet and salty were the characteristic tastes of all fractions, with umami intensity evaluated for the fraction with MW less than 500 Da (F-500) as the most prominent among the three fractions. Subsequent Sephadex G-25 SF fractions and RP-HPLC fractions were subjected to sensory and chemical analyses. The tastiest fraction contained sodium chloride, sugars, organic acids, umami and sweet free amino acids, at concentrations above their thresholds. The abundant presence of umami and sweet free amino acids with certain concentrations of sodium chloride and glucose might provide the typical savory taste of tofuyo. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Quantifying intra- and inter-fractional motion in breast radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Scott, E-mail: scott.jones@health.qld.gov.au [Division of Cancer Services, Radiation Oncology Mater Centre, Princess Alexandra Hospital, Brisbane (Australia); Fitzgerald, Rhys [Division of Cancer Services, Princess Alexandra Hospital, Brisbane (Australia); Owen, Rebecca; Ramsay, Jonathan [Division of Cancer Services, Radiation Oncology Mater Centre, Princess Alexandra Hospital, Brisbane (Australia)

    2015-03-15

    The magnitude of intra- and inter-fractional variation in the set up of breast cancer patients treated with tangential megavoltage photon beams was investigated using an electronic portal imaging device (EPID). Daily cine-EPID images were captured during delivery of the tangential fields for ten breast cancer patients treated in the supine position. Measurements collected from each image included the central lung distance (CLD), central flash distance (CFD), superior axial measurement (SAM) and the inferior axial measurement (IAM). The variation of motion within a fraction (intra-fraction) and the variation between fractions (inter-fraction) was analysed to quantify set up variation and motion due to respiration. Altogether 3775 EPID images were collected from 10 patients. The effect of respiratory motion during treatment was <0.1 cm standard deviation (SD) in the anterior–posterior (AP) direction. The inter-fraction movement caused by variations in daily set up was larger at 0.28 cm SD in the AP direction. Superior–inferior (SI) variation was more difficult to summarise and proved unreliable as the measurements were taken to an ambiguous point on the images. It was difficult to discern true SI movement from that implicated by AP movement. There is minimal intra-fractional chest wall motion due to respiration during treatment. Inter-fractional variation was larger, however, on average it remained within departmental tolerance (0.5 cm) for set up variations. This review of our current breast technique provides confidence in the feasibility of utilising advanced treatment techniques (field-in-field, intensity modulated radiotherapy or volumetric modulated arc therapy) following a review of the current imaging protocol.

  10. Spatiotemporal control of laser intensity

    Science.gov (United States)

    Froula, Dustin H.; Turnbull, David; Davies, Andrew S.; Kessler, Terrance J.; Haberberger, Dan; Palastro, John P.; Bahk, Seung-Whan; Begishev, Ildar A.; Boni, Robert; Bucht, Sara; Katz, Joseph; Shaw, Jessica L.

    2018-05-01

    The controlled coupling of a laser to plasma has the potential to address grand scientific challenges1-6, but many applications have limited flexibility and poor control over the laser focal volume. Here, we present an advanced focusing scheme called a `flying focus', where a chromatic focusing system combined with chirped laser pulses enables a small-diameter laser focus to propagate nearly 100 times its Rayleigh length. Furthermore, the speed at which the focus moves (and hence the peak intensity) is decoupled from the group velocity of the laser. It can co- or counter-propagate along the laser axis at any velocity. Experiments validating the concept measured subluminal (-0.09c) to superluminal (39c) focal-spot velocities, generating a nearly constant peak intensity over 4.5 mm. Among possible applications, the flying focus could be applied to a photon accelerator7 to mitigate dephasing, facilitating the production of tunable XUV sources.

  11. Mapping axonal density and average diameter using non-monotonic time-dependent gradient-echo MRI

    DEFF Research Database (Denmark)

    Nunes, Daniel; Cruz, Tomás L; Jespersen, Sune N

    2017-01-01

    available in the clinic, or extremely long acquisition schemes to extract information from parameter-intensive models. In this study, we suggest that simple and time-efficient multi-gradient-echo (MGE) MRI can be used to extract the axon density from susceptibility-driven non-monotonic decay in the time...... the quantitative results are compared against ground-truth histology, they seem to reflect the axonal fraction (though with a bias, as evident from Bland-Altman analysis). As well, the extra-axonal fraction can be estimated. The results suggest that our model is oversimplified, yet at the same time evidencing......-dependent signal. We show, both theoretically and with simulations, that a non-monotonic signal decay will occur for multi-compartmental microstructures – such as axons and extra-axonal spaces, which we here used in a simple model for the microstructure – and that, for axons parallel to the main magnetic field...

  12. Series expansion in fractional calculus and fractional differential equations

    OpenAIRE

    Li, Ming-Fan; Ren, Ji-Rong; Zhu, Tao

    2009-01-01

    Fractional calculus is the calculus of differentiation and integration of non-integer orders. In a recently paper (Annals of Physics 323 (2008) 2756-2778), the Fundamental Theorem of Fractional Calculus is highlighted. Based on this theorem, in this paper we introduce fractional series expansion method to fractional calculus. We define a kind of fractional Taylor series of an infinitely fractionally-differentiable function. Further, based on our definition we generalize hypergeometric functio...

  13. Effects of liana load, tree diameter and distances between conspecifics on seed production in tropical timber trees

    DEFF Research Database (Denmark)

    Nabe-Nielsen, Jacob; Kollmann, Johannes Christian; Peña-Claros, Marielos

    2009-01-01

    Seed production in tropical timber trees is limited by abiotic resources, pollination and pre-dispersal seed predation. Resource availability is influenced by the number of competing trees and by lianas that often reach high densities in disturbed parts of tropical forests. The distance between...... conspecific trees affects pollination efficiency and seed predation intensity, and may therefore indirectly affect the long-term sustainability of selective logging. Here we investigate how reproductive status and the number of seeds dispersed per tree are affected by liana load, distance to the nearest...... and positively with tree diameter. In C. ianeirensis the most liana-infested trees dispersed fewer seeds. In T. oblonga the intensity of pre-dispersal seed predation decreased with distance to the nearest conspecifics. There was no evidence that seed viability or seed production decreased with distance...

  14. Calculation and measurement of the intensity distribution of 60Co radiation behind block filters

    International Nuclear Information System (INIS)

    Gerlach, R.; Kranepuhl, H.; Salewski, D.

    1987-01-01

    A method for determining the absorption length in block filters with non-focussing edges is described. It accounts for geometric parameters as source diameter, source-surface-distance and the position of the absorber relative to the central ray. The model was checked by intensity measurements. Behind the absorber as well as in the penumbra regions good agreement between calculation and measurement of the intensity distribution was observed. (author)

  15. Accelerated fractionation radiotherapy for advanced haed and neck cancer

    International Nuclear Information System (INIS)

    Lamb, D.S.; Spry, N.A.; Gray, A.J.; Johnson, A.D.; Alexander, S.R.; Dally, M.J.

    1990-01-01

    Between 1981 and 1986, 89 patients with advanced head and neck squamous cancer were treated with a continuous accelerated fractionation radiotherapy (AFRT) regimen. Three fractions of 1.80 Gy, 4 h apart, were given on three treatment days per week, and the tumour dose was taken to 59.40 Gy in 33 fractions in 24-25 days. Acute mucosal reactions were generally quite severe, but a split was avoided by providing the patient with intensive support, often as an in-patient, until the reactions settled. Late radiation effects have been comparable to those obtained with conventional fractionation. The probability of local-regional control was 47% at 3 years for 69 previously untreated patients, whereas it was only 12% at one year for 20 patients treated for recurrence after radical surgery. Fifty-eight previously untreated patients with tumours arising in the upper aero-digestive tract were analysed in greated detail. The probability of local-regional control at 3 years was 78% for 17 Stage III patients and 15% for 31 Stage IV patients. This schedule of continuous AFRT is feasible and merits further investigation. (author). 31 refs.; 4 figs.; 6 tabs

  16. [Carbon isotope fractionation in plants]: Annual technical progress report

    International Nuclear Information System (INIS)

    O'Leary, M.H.

    1988-01-01

    Plants fractionate carbon isotopes during photosynthesis in ways which reflect photosynthetic pathway and environment. The fractionation is product of contributions from diffusion, carboxylation and other factors which can be understood using models which have been developed in our work. The object of our work is to use this fractionation to learn about the factors which control the efficiency of photosynthesis. Unlike previous studies, we do not rely principally on combustion methods, but instead develop more specific methods with substantially higher resolving power. We have recently developed a new short-term method for studying carbon isotope fractionation which promises to provide a level of detail about temperature, species, and light intensity effects on photosynthesis which has not been available until now. We are studying the isotopic compositions of metabolites (particularly aspartic acid) in C 3 plants in order to determine the role of phosphoenolpyruvate carboxylase in C 3 photosynthesis. We are studying the relative roles of diffusion and carboxylation in nocturnal CO 2 fixation in CAM plants. We are studying the use of isotopic content as an index of water-use efficiency in C 3 plants. We are developing new methods for studying carbon metabolism in plants. 3 refs

  17. Observation of the fractional quantum Hall effect in graphene.

    Science.gov (United States)

    Bolotin, Kirill I; Ghahari, Fereshte; Shulman, Michael D; Stormer, Horst L; Kim, Philip

    2009-11-12

    When electrons are confined in two dimensions and subject to strong magnetic fields, the Coulomb interactions between them can become very strong, leading to the formation of correlated states of matter, such as the fractional quantum Hall liquid. In this strong quantum regime, electrons and magnetic flux quanta bind to form complex composite quasiparticles with fractional electronic charge; these are manifest in transport measurements of the Hall conductivity as rational fractions of the elementary conductance quantum. The experimental discovery of an anomalous integer quantum Hall effect in graphene has enabled the study of a correlated two-dimensional electronic system, in which the interacting electrons behave like massless chiral fermions. However, owing to the prevailing disorder, graphene has so far exhibited only weak signatures of correlated electron phenomena, despite intense experimental and theoretical efforts. Here we report the observation of the fractional quantum Hall effect in ultraclean, suspended graphene. In addition, we show that at low carrier density graphene becomes an insulator with a magnetic-field-tunable energy gap. These newly discovered quantum states offer the opportunity to study correlated Dirac fermions in graphene in the presence of large magnetic fields.

  18. Catalytic growth of carbon nanotubes with large inner diameters

    Directory of Open Access Journals (Sweden)

    WEI REN ZHONG

    2005-02-01

    Full Text Available Carbon nanotubes (2.4 g/g catalyst, with large inner diameters were successfully synthesized through pyrolysis of methane on a Ni–Cu–Al catalyst by adding sodium carbonate into the carbon nanotubes growth system. The inner diameter of the carbon nanotubes prepared by this method is about 20–60 nm, while their outer diameter is about 40–80 nm. Transmission electron microscopy and X-ray diffraction were employed to investigate the morphology and microstructures of the carbon nanotubes. The analyses showed that these carbon nanotubes have large inner diameters and good graphitization. The addition of sodium carbonate into the reaction system brings about a slight decrease in the methane conversion and the yield of carbon. The experimental results showed that sodium carbonate is a mildly toxic material which influenced the catalytic activity of the Ni–Cu–Al catalyst and resulted in the formation of carbon nanotubes with large inner diameters. The growth mechanism of the carbon nanotubes with large inner diameters is discussed in this paper.

  19. On the diameter of dot-critical graphs

    Directory of Open Access Journals (Sweden)

    Doost Ali Mojdeh

    2009-01-01

    Full Text Available A graph G is \\(k\\-dot-critical (totaly \\(k\\-dot-critical if \\(G\\ is dot-critical (totaly dot-critical and the domination number is \\(k\\. In the paper [T. Burtona, D. P. Sumner, Domination dot-critical graphs, Discrete Math, 306 (2006, 11-18] the following question is posed: What are the best bounds for the diameter of a \\(k\\-dot-critical graph and a totally \\(k\\-dot-critical graph \\(G\\ with no critical vertices for \\(k \\geq 4\\? We find the best bound for the diameter of a \\(k\\-dot-critical graph, where \\(k \\in\\{4,5,6\\}\\ and we give a family of \\(k\\-dot-critical graphs (with no critical vertices with sharp diameter \\(2k-3\\ for even \\(k \\geq 4\\.

  20. The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulation

    International Nuclear Information System (INIS)

    Carol, Mark; Grant, Walter H.; Bleier, Alan R.; Kania, Alex A.; Targovnik, Harris S.; Butler, E. Brian; Shiao, W. Woo

    1996-01-01

    Purpose: Intensity modulated beam systems have been developed as a means of creating a high-dose region that closely conforms to the prescribed target volume while also providing specific sparing of organs at risk within complex treatment geometries. The slice-by-slice treatment paradigm used by one such system for delivering intensity modulated fields introduces regions of dose nonuniformity where each pair of treatment slices abut. A study was designed to evaluate whether or not the magnitude of the nonuniformity that results from this segmental delivery paradigm is significant relative to the overall dose nonuniformity present in the intensity modulation technique itself. An assessment was also made as to the increase in nonuniformity that would result if errors were made in indexing during treatment delivery. Methods and Materials: Treatment plans were generated to simulate correctly indexed and incorrectly indexed treatments of 4, 10, and 18 cm diameter targets. Indexing errors of from 0.1 to 2.0 mm were studied. Treatment plans were also generated for targets of the same diameter but of lengths that did not require indexing of the treatment couch. Results: The nonuniformity that results from the intensity modulation delivery paradigm is 11-16% for targets where indexing is not required. Correct indexing of the couch adds an additional 1-2% in nonuniformity. However, a couch indexing error of as little as 1 mm can increase the total nonuniformity to as much as 25%. All increases in nonuniformity from indexing are essentially independent of target diameter. Conclusions: The dose nonuniformity introduced by the segmental strip delivery paradigm is small relative to the nonuniformity present in the intensity modulation paradigm itself. A positioning accuracy of better than 0.5 mm appears to be required when implementing segmental intensity modulated treatment plans

  1. Nonhomogeneous fractional Poisson processes

    Energy Technology Data Exchange (ETDEWEB)

    Wang Xiaotian [School of Management, Tianjin University, Tianjin 300072 (China)]. E-mail: swa001@126.com; Zhang Shiying [School of Management, Tianjin University, Tianjin 300072 (China); Fan Shen [Computer and Information School, Zhejiang Wanli University, Ningbo 315100 (China)

    2007-01-15

    In this paper, we propose a class of non-Gaussian stationary increment processes, named nonhomogeneous fractional Poisson processes W{sub H}{sup (j)}(t), which permit the study of the effects of long-range dependance in a large number of fields including quantum physics and finance. The processes W{sub H}{sup (j)}(t) are self-similar in a wide sense, exhibit more fatter tail than Gaussian processes, and converge to the Gaussian processes in distribution in some cases. In addition, we also show that the intensity function {lambda}(t) strongly influences the existence of the highest finite moment of W{sub H}{sup (j)}(t) and the behaviour of the tail probability of W{sub H}{sup (j)}(t)

  2. Study of the properties of the anthracene fraction by the thermogravimetric method

    Energy Technology Data Exchange (ETDEWEB)

    Belkina, T.V.; Chernyak, P.E.; Ulanovskii, M.L.

    1980-01-01

    With the use of the TGA method, the effect of temperature, thermal exposure time, a179975d the medium on the relation of the rates and the intensity of the processes of distillation and synthesis during thermal treatment of the anthracene fraction were determined.

  3. Acoustic bubble enhanced pinched flow fractionation for microparticle separation

    International Nuclear Information System (INIS)

    Zhou, Ran; Wang, Cheng

    2015-01-01

    Pinched flow fractionation is a simple method for separating micron-sized particles by size, but has certain intrinsic limitations, e.g. requirement of a pinched segment similar to particle size and limited separation distance. In this paper, we developed an acoustic bubble enhanced pinched flow fractionation (PFF) method for microparticle separation. The proposed technique utilized microbubble streaming flows to overcome the limitations of conventional PFF. Our device has demonstrated separation of different sized microparticles (diameters 10 and 2 μm) with a larger pinched segment (60 μm) and at different buffer/particle solution flow rate ratios (5–25). The separation distances between particles are larger (as much as twice as large) than those achieved with conventional PFF. In addition, the separation position and distance can be adjusted by changing the driving voltage. The robust performance is due to the unique features of the flow field inside the pinched segment. We investigated several factors, including flow rate ratio, total flow rate and driving voltage, that affect the separation performance. (paper)

  4. On the performance of small diameter gas cyclones

    International Nuclear Information System (INIS)

    Halasz, Marcos Roberto Teixeira

    2002-02-01

    Small diameter cyclones represent a potential alternative for the removal of small diameter particles from gaseous mixtures as well as the environmental control of their emission. In order to establish feasible configurations of a small diameter cyclone applied in the separation of solid particles dispersed in a gas and considering a large quantify of experimental data in literature, neural networks were used to estimate the equipment grade efficiency and pressure drop. In order to evaluate a performance of many small diameters configurations and analysis was carried of parametrical sensibility which determines the most important variables on separation efficiency determination. A set of experimental runs was carried out in a lab-scale mini-cyclone in order to obtain the separation efficiency and pressure drop for different configurations, and evaluate the feasibility of coupling a post-cyclone device to improve the equipment overall performance. The cyclones used presented diameters of 0.03 and 0.05 m and the remaining dimensions varied proportionally about those found in Stairmand high-efficiency cyclones. Experimental separation efficiencies up to 99% were obtained in this work. These results confirm the feasibility of the experimental set-up configuration proposed. (author)

  5. Fractional governing equations of transient groundwater flow in confined aquifers with multi-fractional dimensions in fractional time

    Directory of Open Access Journals (Sweden)

    M. L. Kavvas

    2017-10-01

    Full Text Available Using fractional calculus, a dimensionally consistent governing equation of transient, saturated groundwater flow in fractional time in a multi-fractional confined aquifer is developed. First, a dimensionally consistent continuity equation for transient saturated groundwater flow in fractional time and in a multi-fractional, multidimensional confined aquifer is developed. For the equation of water flux within a multi-fractional multidimensional confined aquifer, a dimensionally consistent equation is also developed. The governing equation of transient saturated groundwater flow in a multi-fractional, multidimensional confined aquifer in fractional time is then obtained by combining the fractional continuity and water flux equations. To illustrate the capability of the proposed governing equation of groundwater flow in a confined aquifer, a numerical application of the fractional governing equation to a confined aquifer groundwater flow problem was also performed.

  6. Diameter dependent electron transfer kinetics in semiconductor-enzyme complexes.

    Science.gov (United States)

    Brown, Katherine A; Song, Qing; Mulder, David W; King, Paul W

    2014-10-28

    Excited state electron transfer (ET) is a fundamental step for the catalytic conversion of solar energy into chemical energy. To understand the properties controlling ET between photoexcited nanoparticles and catalysts, the ET kinetics were measured for solution-phase complexes of CdTe quantum dots and Clostridium acetobutylicum [FeFe]-hydrogenase I (CaI) using time-resolved photoluminescence spectroscopy. Over a 2.0-3.5 nm diameter range of CdTe nanoparticles, the observed ET rate (kET) was sensitive to CaI concentration. To account for diameter effects on CaI binding, a Langmuir isotherm and two geometric binding models were created to estimate maximal CaI affinities and coverages at saturating concentrations. Normalizing the ET kinetics to CaI surface coverage for each CdTe diameter led to k(ET) values that were insensitive to diameter, despite a decrease in the free energy for photoexcited ET (ΔGET) with increasing diameter. The turnover frequency (TOF) of CaI in CdTe-CaI complexes was measured at several molar ratios. Normalization for diameter-dependent changes in CaI coverage showed an increase in TOF with diameter. These results suggest that k(ET) and H2 production for CdTe-CaI complexes are not strictly controlled by ΔG(ET) and that other factors must be considered.

  7. Attached and Unattached Activity Size Distribution of Short-Lived Radon Progeny (214Pb) and Evaluation of Deposition Fraction

    International Nuclear Information System (INIS)

    Mohamed, A.; Ahmed, A.A.; Ali, A.E.; Yuness, M.

    2009-01-01

    Inhalation of 2 '2 2 Rn progeny in the domestic environment contributes the greatest fraction of the natural radiation exposure to the public. Dosimetric models are most often used in the assessment of human lung doses due to inhaled radioactivity because of the difficulty in making direct measurements. These models require information about the parameters of activity size distributions of radon progeny. The current study presents measured data on the attached and unattached activity size distributions of radon progeny in indoor air in El-Minia, Egypt. The attached fraction was collected using a low pressure Berner cascade impactor technique. A screen diffusion battery was used for collecting the unattached fraction. Most of the attached activities for 222 Rn progeny were associated with aerosol particles of the accumulation mode. The mean activity median aerodynamic diameter (AMAD) of this mode for 21 4 P b was determined to be 401 nm with relative mean geometric standard deviation of 2.96. The mean value of specific air activity concentration of 214 Pb associated with that mode was determined to be 4.74 %0.44 Bq m -3 . The relative mean geometric standard deviations of unattached 214 Pb was determined to be 1.21 with the mean activity thermodynamic diameter (AMTD) of 1.2 nm. The mean unattached activity concentration of 214 Pb was found to be 0.44%0.14 Bq m-3. Based on the obtained results of radon progeny size distributions (unattached and attached), the deposition fractions in each airway generation of the human lung were evaluated by using a lung deposition model

  8. Dosimetric characteristics with spatial fractionation using electron grid therapy.

    Science.gov (United States)

    Meigooni, A S; Parker, S A; Zheng, J; Kalbaugh, K J; Regine, W F; Mohiuddin, M

    2002-01-01

    Recently, promising clinical results have been shown in the delivery of palliative treatments using megavoltage photon grid therapy. However, the use of megavoltage photon grid therapy is limited in the treatment of bulky superficial lesions where critical radiosensitive anatomical structures are present beyond tumor volumes. As a result, spatially fractionated electron grid therapy was investigated in this project. Dose distributions of 1.4-cm-thick cerrobend grid blocks were experimentally determined for electron beams ranging from 6 to 20 MeV. These blocks were designed and fabricated at out institution to fit into a 20 x 20-cm(2) electron cone of a commercially available linear accelerator. Beam profiles and percentage depth dose (PDD) curves were measured in Solid Water phantom material using radiographic film, LiF TLD, and ionometric techniques. Open-field PDD curves were compared with those of single holes grid with diameters of 1.5, 2.0, 2.5, 3.0, and 3.5 cm to find the optimum diameter. A 2.5-cm hole diameter was found to be the optimal size for all electron energies between 6 and 20 MeV. The results indicate peak-to-valley ratios decrease with depth and the largest ratio is found at Dmax. Also, the TLD measurements show that the dose under the blocked regions of the grid ranged from 9.7% to 39% of the dose beneath the grid holes, depending on the measurement location and beam energy.

  9. Final Report for Fractionation and Separation of Polydisperse Nanoparticles into Distinct Monodisperse Fractions Using CO2 Expanded Liquids

    Energy Technology Data Exchange (ETDEWEB)

    Chistopher Roberts

    2007-08-31

    moving the liquid nanoparticle dispersion from the top vessel to the bottom vessel with corresponding CO{sub 2} pressure increases at each stage. For example, three fractions with average diameters of 7.00 nm, 4.35 nm, and 3.95 nm were recovered from a 20ml sample of Ag nanoparticles dispersed in hexane at pressures of 625 psi, 650 psi, >650 psi, respectively.

  10. Modelling of tomato stem diameter growth rate based on physiological responses

    International Nuclear Information System (INIS)

    Li, L.; Tan, J.; Lv, T.

    2017-01-01

    The stem diameter is an important parameter describing the growth of tomato plant during vegetative growth stage. A stem diameter growth model was developed to predict the response of plant growth under different conditions. By analyzing the diurnal variations of stem diameter in tomato (Solanum lycopersicum L.), it was found that the stem diameter measured at 3:00 am was the representative value as the daily basis of tomato stem diameter. Based on the responses of growth rate in stem diameter to light and temperature, a linear regression relationship was applied to establish the stem diameter growth rate prediction model for the vegetative growth stage in tomato and which was further validated by experiment. The root mean square error (RMSE) and relative error (RE) were used to test the correlation between measured and modeled stem diameter variations. Results showed that the model can be used in prediction for stem diameter growth rate at vegetative growth stage in tomato. (author)

  11. Effects of fractionated stereotactic radiotherapy for primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Choi, Byeong Ock; Jang, Hong Seok; Kang, Young Nam; Choi, Ihl Bhong; Kang, Ki Mun; Chai, Gyu Young; Lee, Sang Wook

    2005-01-01

    Reports on the outcome of curative radiotherapy for the primary hepatocellular carcinoma (HCC) are rarely encountered in the literature. In this study, we report our experience of a clinical trial where fractionated stereotactic radiotherapy (SRT) was used in treating a primary HCC. A retrospective analysis was performed on 20 patients who had been histologically diagnosed as HCC and treated by fractionated SRT. The long diameter of tumor measured by CT was 2 ∼ 6.5 cm (average: 3.8 cm). A single dose of radiation used in fractionated SRT was 5 or 10 Gy; each dose was prescribed based on the planning target volume and normalized to 85 ∼ 99% isocenter dose. Patients were treated 3 ∼ 5 times per week for 2 weeks, with each receiving a total dose of 50 Gy (the median dose: 50 Gy). The follow up period was 3 ∼ 55 months (the median follow up period: 23 months). The response rate was 60% (12 patients), with 4 patients showing complete response (20%), 8 patients showing partial response (40%), and 8 patients showing stable disease (40%). The 1-year and 2-year survival rates were 70.0% and 43.1%, respectively,and the median survival time was 20 months. The 1-year and 2-year disease free survival rates were 65% and 32.5%, respectively, and the median disease-free survival rate was 19 months. Some acute complications of the treatment were noted as follows: dyspepsia in 12 patients (60%), nausea/emesis in 8 patients (40%), and transient liver function impairment in 6 patients (30%). However, there was no treatment related death. The study indicates that fractionated SRT is a relatively safe and effective method for treating primary HCC. Thus, fractionated SRT may be suggested as a local treatment for HCC of small lesion and containing a single lesion, when the patients are inoperable or operation is refused by the patients. We thought that fractionated SRT is a challenging treatment modality for the HCC

  12. Mathematical modeling of fish burger baking using fractional calculus

    Directory of Open Access Journals (Sweden)

    Bainy Eduarda M.

    2017-01-01

    Full Text Available Tilapia (Oreochromis sp. is the most important and abundant fish species in Brazil due to its adaptability to different environments. The development of tilapia-based products could be an alternative in order to aggregate value and increase fish meat consumption. However, there is little information available on fishburger freezing and cooking in the literature. In this work, the mathematical modeling of the fish burger baking was studied. Previously to the baking process, the fishburgers were assembled in cylindrical shape of height equal to 8mm and diameter 100mm and then baked in an electrical oven with forced heat convection at 150ºC. A T-type thermocouple was inserted in the burger to obtain its temperature profile at the central position. In order to describe the temperature of the burger during the baking process, lumped-parameter models of integer and fractional order and also a nonlinear model due to heat capacity temperature dependence were considered. The burger physical properties were obtained from the literature. After proper parameter estimation tasks and statistical validation, the fractional order model could better describe the experimental temperature behavior, a value of 0.91±0.02 was obtained for the fractional order of the system with correlation coefficient of 0.99. Therefore, with the better temperature prediction, process control and economic optimization studies of the baking process can be conducted.

  13. Role of Rad52 in fractionated irradiation induced signaling in A549 lung adenocarcinoma cells

    International Nuclear Information System (INIS)

    Ghosh, Somnath; Krishna, Malini

    2012-01-01

    The effect of fractionated doses of γ-irradiation (2 Gy per fraction over 5 days), as delivered in cancer radiotherapy, was compared with acute doses of 10 and 2 Gy, in A549 cells. A549 cells were found to be relatively more radioresistant if the 10 Gy dose was delivered as a fractionated regimen. Microarray analysis showed upregulation of DNA repair and cell cycle arrest genes in the cells exposed to fractionated irradiation. There was intense activation of DNA repair pathway-associated genes (DNA-PK, ATM, Rad52, MLH1 and BRCA1), efficient DNA repair and phospho-p53 was found to be translocated to the nucleus of A549 cells exposed to fractionated irradiation. MCF-7 cells responded differently in fractionated regimen. Silencing of the Rad52 gene in fractionated group of A549 cells made the cells radiosensitive. The above result indicated increased radioresistance in A549 cells due to the activation of Rad52 gene.

  14. Fractional governing equations of transient groundwater flow in confined aquifers with multi-fractional dimensions in fractional time

    OpenAIRE

    M. L. Kavvas; T. Tu; A. Ercan; J. Polsinelli

    2017-01-01

    Using fractional calculus, a dimensionally consistent governing equation of transient, saturated groundwater flow in fractional time in a multi-fractional confined aquifer is developed. First, a dimensionally consistent continuity equation for transient saturated groundwater flow in fractional time and in a multi-fractional, multidimensional confined aquifer is developed. For the equation of water flux within a multi-fractional multidimensional confined aquifer, a dimensionally...

  15. Multi-diameter pigging: factors affecting the design and selection of pigging tools for multi-diameter pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Karl [Pipeline Engineering and Supply Co. Ltd., Richmond, NY (United States)

    2009-07-01

    This paper will consider the process involved in pigging tool selection for pipelines with two or more significant internal diameters which require pigging tools capable of negotiating the different internal diameters whilst also carrying out the necessary pipeline cleaning operation. The paper will include an analysis of pipeline features that affect pigging tool selection and then go on to look at other variables that determine the pigging tool design; this will include a step by step guide outlining how the tool is designed, the development of prototype pigs and the importance of testing and validation prior to final deployment in operational pigging programmes. (author)

  16. Elemental fractionation in 785 nm picosecond and femtosecond laser ablation inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Shaheen, M.E.; Gagnon, J.E.; Fryer, B.J.

    2015-01-01

    Elemental fractionation and ICP-MS signal response were investigated for two different pulse width laser beams originating from the same laser system. Femtosecond and picosecond laser beams at pulse widths of 130 fs and 110 ps, respectively, and wavelength of 785 nm were used to ablate NIST 610 synthetic glass and SRM 1107 Naval Brass B at the same spot for 800 to 1000 laser pulses at different repetition rates (5 to 50 Hz). Elemental fractionation was found to depend on repetition rate and showed a trend with femtosecond laser ablation that is opposite to that observed in picosecond laser ablation for most measured isotopes. ICP-MS signal intensity was higher in femtosecond than picosecond LA-ICP-MS in both NIST 610 and naval brass when ablation was conducted under the same fluence and repetition rate. The differences in signal intensity were partly related to differences in particle size distribution between particles generated by femtosecond and picosecond laser pulses and the consequent differences in transport and ionization efficiencies. The main reason for the higher signal intensity resulting from femtosecond laser pulses was related to the larger crater sizes compared to those created during picosecond laser ablation. Elemental ratios measured using 66 Zn/ 63 Cu, 208 Pb/ 238 U, 232 Th/ 238 U, 66 Zn/ 232 Th and 66 Zn/ 208 Pb were found to change with the number of laser pulses with data points being more scattered in picosecond than femtosecond laser pulses. Reproducibility of replicate measurements of signal intensities, fractionation and elemental ratios was better for fs-LA-ICP-MS (RSD ~ 3 to 6%) than ps-LA-ICP-MS (RSD ~ 7 to 11%). - Highlights: • Fractionation and ICP-MS signal response were investigated for two different pulse widths using NIST 610 and Naval Brass. • Dependence of fractionation indices on repetition rate and pulse width. • Higher ablation rate was observed in picosecond compared to femtosecond laser ablation of NIST 610 and Brass

  17. Enhancement of Si solar cell efficiency using ZnO nanowires with various diameters

    Science.gov (United States)

    Gholizadeh, A.; Reyhani, A.; Parvin, P.; Mortazavi, S. Z.; Mehrabi, M.

    2018-01-01

    Here, Zinc Oxide nanowires are synthesized using thermal chemical vapor deposition of a Zn granulate source and used to enhance a significant Si-solar cell efficiency with simple and low cost method. The nanowires are grown in various O2 flow rates. Those affect the shape, yield, structure and the quality of ZnO nanowires according to scanning electron microscopy and x-ray diffraction analyses. This delineates that the ZnO nanostructure is dependent on the synthesis conditions. The photoluminescence spectroscopy of ZnO indicates optical emission at the Ultra-Violet and blue-green regions whose intensity varies as a function of diameter of ZnO nano-wires. The optical property of ZnO layer is measured by UV-visible and diffuse reflection spectroscopy that demonstrate high absorbance at 280-550 nm. Furthermore, the photovoltaic characterization of ZnO nanowires is investigated based on the drop casting on Si-solar cell. The ZnO nanowires with various diameters demonstrate different effects on the efficiency of Si-solar cells. We have shown that the reduction of the spectral reflectance and down-shifting process as well as the reduction of photon trapping are essential parameters on the efficiency of Si-solar cells. However, the latter is dominated here. In fact, the trapped photons during the electron-hole generation are dominant due to lessening the absorption rate in ZnO nano-wires. The results indicate that the mean diameters reduction of ZnO nanowires is also essential to improve the fill factor. The external and internal quantum efficiency analyses attest the efficiency improvement over the blue region which is related to the key parameters above.

  18. Heritability of retinal vessel diameters and blood pressure

    DEFF Research Database (Denmark)

    Taarnhøj, Nina C B B; Larsen, Michael; Sander, Birgit

    2006-01-01

    PURPOSE: To assess the relative influence of genetic and environmental effects on retinal vessel diameters and blood pressure in healthy adults, as well as the possible genetic connection between these two characteristics. METHODS: In 55 monozygotic and 50 dizygotic same-sex healthy twin pairs......%-80%) for CRAE, 83% (95% CI: 73%-89%) for CRVE, and 61% (95% CI: 44%-73%) for mean arterial blood pressure (MABP). Retinal artery diameter decreased with increasing age and increasing arterial blood pressure. Mean vessel diameters in the population were 165.8 +/- 14.9 microm for CRAE, 246.2 +/- 17.7 microm...... for CRVE, and 0.67 +/- 0.05 microm for AVR. No significant influence on artery or vein diameters was found for gender, smoking, body mass index (BMI), total cholesterol, fasting blood glucose, or 2-hour oral glucose tolerance test values. CONCLUSIONS: In healthy young adults with normal blood pressure...

  19. Planar measurements of soot volume fraction and OH in a JP-8 pool fire

    Energy Technology Data Exchange (ETDEWEB)

    Henriksen, Tara L.; Ring, Terry A.; Eddings, Eric G. [Department of Chemical Engineering, University of Utah, Salt Lake City, UT 84112 (United States); Nathan, Graham J. [School of Mechanical Engineering, University of Adelaide, SA 5005 (Australia); Alwahabi, Zeyad T.; Qamar, Nader [School of Chemical Engineering, University of Adelaide, SA 5005 (Australia)

    2009-07-15

    The simultaneous measurement of soot volume fraction by laser induced incandescence (LII) and qualitative imaging of OH by laser induced fluorescence (LIF) was performed in a JP-8 pool fire contained in a 152 mm diameter pan. Line of sight extinction was used to calibrate the LII system in a laminar flame, and to provide an independent method of measuring average soot volume fraction in the turbulent flame. The presence of soot in the turbulent flame was found to be approximately 50% probable, resulting in high levels of optical extinction, which increased slightly through the flame from approximately 30% near the base, to approximately 50% at the tip. This high soot loading pushes both techniques toward their detection limit. Nevertheless, useful accuracy was obtained, with the LII measurement of apparent extinction in the turbulent flame being approximately 21% lower than a direct measurement, consistent with the influence of signal trapping. The axial and radial distributions of soot volume fraction are presented, along with PDFs of volume fraction, and new insight into the behavior of soot sheets in pool fires are sought from the simultaneous measurements of OH and LII. (author)

  20. Lumbar Vertebral Canal Diameters in Adult Ugandan Skeletons ...

    African Journals Online (AJOL)

    Background: Normal values of lumbar vertebral canal diameters are useful in facilitating diagnosis of lumbar vertebral canal stenosis. Various studies have established variation on values between different populations, gender, age, and ethnic groups. Objectives: To determine the lumbar vertebral canal diameters in adult ...

  1. Moisture monitoring in large diameter boreholes

    International Nuclear Information System (INIS)

    Tyler, S.

    1985-01-01

    The results of both laboratory and field experiments indicate that the neutron moisture gauge traditionally used in soil physics experiments can be extended for use in large diameter (up to 15 cm) steel-cased boreholes with excellent results. This application will permit existing saturated zone monitoring wells to be used for unsaturated zone monitoring of recharge, redistribution and leak detection from waste disposal facilities. Its applicability to large diameter cased wells also gives the soil physicist and ground-water hydrologist and new set of monitoring points in the unsaturated zone to study recharge and aquifer properties. 6 refs., 6 figs., 2 tabs

  2. Diameter dependent failure current density of gold nanowires

    International Nuclear Information System (INIS)

    Karim, S; Maaz, K; Ali, G; Ensinger, W

    2009-01-01

    Failure current density of single gold nanowires is investigated in this paper. Single wires with diameters ranging from 80 to 720 nm and length 30 μm were electrochemically deposited in ion track-etched single-pore polycarbonate membranes. The maximum current density was investigated while keeping the wires embedded in the polymer matrix and ramping up the current until failure occurred. The current density is found to increase with diminishing diameter and the wires with a diameter of 80 nm withstand 1.2 x 10 12 A m -2 before undergoing failure. Possible reasons for these results are discussed in this paper.

  3. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... exertion was approximately 15 units after both types of exercise. The dorsalis pedis arterial diameter was 1.50 +/- 0.20 mm (mean and SE) and the radial AD 2.45 +/- 0.12 mm. During both types of contractions the luminal diameters decreased approximately 3.5% within the first 30 s (P

  4. Effective diameters and corresponding states of fluids

    Science.gov (United States)

    Del Río, Fernando

    Effective hard-sphere diameters of fluids with purely repulsive interactions are derived from a generalized corresponding-states principle of Leland, Rowlinson and coworkers. Various alternative definitions are discussed and related. Virial expansions of the effective diameters and their corresponding volumes are obtained and compared with results of perturbation theory. Applications are made to inverse-power potentials, the repulsive part of the Lennard-Jones potential and hard spherocylinders and dumbells.

  5. Comparison between transcerebellar diameter with biparietal diameter of ultrasound for gestational age measurement in third trimester of pregnancy

    International Nuclear Information System (INIS)

    Naseem, F.; Fatima, N.; Yasmeen, S.; Saleem, S.

    2013-01-01

    To determine the frequency of correct assessment by transcerebeller diameter (TCD) versus biparietal diameter (BPD) for gestational age measurement at 36 weeks of pregnancy using first day of last menstrual period (LMP) for actual period of gestation. Study Design: Quasi experimental. Place and Duration of Study: Department of Obstetrics and Gynaecology, Bahawal Victoria Hospital, Bahawalpur from May to November 2010. Methodology: This study was performed on 228 patients at 36 weeks of pregnancy fulfilling the inclusion criteria. Ultrasound measurements of TCD and BPD was made and compared with LMP. Collected data was analyzed by SPSS version 10. Proportoin of correct diagnosis by each measurement was determined and compared using chi-square test with significance at p < 0.05. Results: Out of 228 patients, TCD was found to give correct assessment in 209 patients (91.7%; p = 0.001) corresponding to the gestational age by LMP i.e 36 weeks. BPD was found to give correct assessment corresponding to the gestational age by LMP in 176 patients (77.2%). Conclusion: Although both BPD and TCD are accurate biometric parameters at 36 weeks of gestation, transcerebellar diameter is more reliable method of gestational age determination in third trimester of pregnancy than biparietal diameter. TCD can be used as a tool to assist in the assessment of gestational age in third trimester. (author)

  6. Response of soil organic carbon fractions, microbial community composition and carbon mineralization to high-input fertilizer practices under an intensive agricultural system

    Science.gov (United States)

    Wu, Xueping; Gebremikael, Mesfin Tsegaye; Wu, Huijun; Cai, Dianxiong; Wang, Bisheng; Li, Baoguo; Zhang, Jiancheng; Li, Yongshan; Xi, Jilong

    2018-01-01

    Microbial mechanisms associated with soil organic carbon (SOC) decomposition are poorly understood. We aim to determine the effects of inorganic and organic fertilizers on soil labile carbon (C) pools, microbial community structure and C mineralization rate under an intensive wheat-maize double cropping system in Northern China. Soil samples in 0–10 cm layer were collected from a nine-year field trial involved four treatments: no fertilizer, CK; nitrogen (N) and phosphorus (P) fertilizers, NP; maize straw combined with NP fertilizers, NPS; and manure plus straw and NP fertilizers, NPSM. Soil samples were analyzed to determine labile C pools (including dissolved organic C, DOC; light free organic C, LFOC; and microbial biomass C, MBC), microbial community composition (using phospholipid fatty acid (PLFA) profiles) and SOC mineralization rate (from a 124-day incubation experiment). This study demonstrated that the application of chemical fertilizers (NP) alone did not alter labile C fractions, soil microbial communities and SOC mineralization rate from those observed in the CK treatment. Whereas the use of straw in conjunction with chemical fertilizers (NPS) became an additional labile substrate supply that decreased C limitation, stimulated growth of all PLFA-related microbial communities, and resulted in 53% higher cumulative mineralization of C compared to that of CK. The SOC and its labile fractions explained 78.7% of the variance of microbial community structure. Further addition of manure on the top of straw in the NPSM treatment did not significantly increase microbial community abundances, but it did alter microbial community structure by increasing G+/G- ratio compared to that of NPS. The cumulative mineralization of C was 85% higher under NPSM fertilization compared to that of CK. Particularly, the NPSM treatment increased the mineralization rate of the resistant pool. This has to be carefully taken into account when setting realistic and effective goals

  7. Mechanical behaviors of the dispersion nuclear fuel plates induced by fuel particle swelling and thermal effect II: Effects of variations of the fuel particle diameters

    International Nuclear Information System (INIS)

    Ding Shurong; Wang Qiming; Huo Yongzhong

    2010-01-01

    In order to predict the irradiation mechanical behaviors of plate-type dispersion nuclear fuel elements, the total burnup is divided into two stages: the initial stage and the increasing stage. At the initial stage, the thermal effects induced by the high temperature differences between the operation temperatures and the room temperature are mainly considered; and at the increasing stage, the intense mechanical interactions between the fuel particles and the matrix due to the irradiation swelling of fuel particles are focused on. The large-deformation thermo-elasto-plasticity finite element analysis is performed to evaluate the effects of particle diameters on the in-pile mechanical behaviors of fuel elements. The research results indicate that: (1) the maximum Mises stresses and equivalent plastic strains at the matrix increase with the fuel particle diameters; the effects of particle diameters on the maximum first principal stresses vary with burnup, and the considered case with the largest particle diameter holds the maximum values all along; (2) at the cladding near the interface between the fuel meat and the cladding, the Mises stresses and the first principal stresses undergo major changes with increasing burnup, and different variations exist for different particle diameter cases; (3) the maximum Mises stresses at the fuel particles rise with the particle diameters.

  8. Heritability of optic disc diameters: a twin study

    DEFF Research Database (Denmark)

    Drobnjak, Dragana; Taarnhøj, Nina Charlotte; Mitchell, Paul

    2011-01-01

    , additive genetic factors (i.e. heritability) explained 77% (95% CI: 65-85%) of variation of vertical disc diameters, whereas estimated unshared environmental effect was 23% (95% CI: 15-35%). For vertical cup diameters, heritability accounted for 70% (95% CI: 55-80%) and environmental factors 30% (95% CI...

  9. Ablative fractional carbon dioxide laser combined with intense pulsed light for the treatment of photoaging skin in Chinese population: A split-face study.

    Science.gov (United States)

    Mei, Xue-Ling; Wang, Li

    2018-01-01

    Intense pulsed light (IPL) is effective for the treatment of lentigines, telangiectasia, and generalized erythema, but is less effective in the removal of skin wrinkles. Fractional laser is effective on skin wrinkles and textural irregularities, but can induce postinflammatory hyperpigmentation (PIH), especially in Asians. This study evaluated the safety and efficacy of ablative fractional laser (AFL) in combination with IPL in the treatment of photoaging skin in Asians.This study included 28 Chinese women with Fitzpatrick skin type III and IV. The side of the face to be treated with IPL alone (3 times) or AFL in combination with IPL (2 IPL treatments and 1 AFL treatment) was randomly selected. Skin conditions including hydration, transepidermal water loss, elasticity, spots, ultraviolet spots, brown spots, wrinkle, texture, pore size and red areas, as well as adverse effects were evaluated before the treatment and at 30 days after the treatment.Compared with IPL treatment alone, AFL in combination with IPL significantly increased elasticity, decreased pore size, reduced skin wrinkles, and improved skin texture (P = .004, P = .039, P = .015, and P = .035, respectively). Both treatment protocols produced similar effects in relation to the improvement of photoaging-induced pigmentation. The combined therapy did not impair epidermal barrier function. No postoperative infection, hypopigmentation, or scarring occurred after IPL and AFL treatments. PIH occurred at 1 month after AFL treatment and disappeared at 30 days after completion of the combined therapy.AFL in combination with IPL is safe and effective for photoaging skin in Asians. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  10. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    Science.gov (United States)

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  11. Brain Arterial Diameters as a Risk Factor for Vascular Events.

    Science.gov (United States)

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-08-06

    Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, called the brain arterial remodeling (BAR) score, was obtained by averaging the measured diameters within each individual. Individuals with a BAR score -2 and 2 SDs had the largest diameters. All vascular events were recorded prospectively after the brain magnetic resonance imaging. Spline curves and incidence rates were used to test our hypothesis. The association of the BAR score with death (P=0.001), vascular death (P=0.02), any vascular event (P=0.05), and myocardial infarction (P=0.10) was U-shaped except for ischemic stroke (P=0.74). Consequently, incidence rates for death, vascular death, myocardial infarction, and any vascular event were higher in individuals with the largest diameters, whereas individuals with the smallest diameters had a higher incidence of death, vascular death, any vascular event, and ischemic stroke compared with individuals with average diameters. The risk of death, vascular death, and any vascular event increased at both extremes of brain arterial diameters. The pathophysiology linking brain arterial remodeling to systemic vascular events needs further research. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  12. Numerical evaluation of droplet sizing based on the ratio of fluorescent and scattered light intensities (LIF/Mie technique)

    International Nuclear Information System (INIS)

    Charalampous, Georgios; Hardalupas, Yannis

    2011-01-01

    The dependence of fluorescent and scattered light intensities from spherical droplets on droplet diameter was evaluated using Mie theory. The emphasis is on the evaluation of droplet sizing, based on the ratio of laser-induced fluorescence and scattered light intensities (LIF/Mie technique). A parametric study is presented, which includes the effects of scattering angle, the real part of the refractive index and the dye concentration in the liquid (determining the imaginary part of the refractive index). The assumption that the fluorescent and scattered light intensities are proportional to the volume and surface area of the droplets for accurate sizing measurements is not generally valid. More accurate sizing measurements can be performed with minimal dye concentration in the liquid and by collecting light at a scattering angle of 60 deg. rather than the commonly used angle of 90 deg. Unfavorable to the sizing accuracy are oscillations of the scattered light intensity with droplet diameter that are profound at the sidescatter direction (90 deg.) and for droplets with refractive indices around 1.4.

  13. Small-field fractionated radiotherapy with or without stereotactic boost for vestibular schwannoma

    International Nuclear Information System (INIS)

    Kagei, K.; Shirato, H.; Suzuki, K.; Isu, T.; Sawamura, Y.; Sakamoto, T.; Fukuda, S.; Nishioka, T.; Hashimoto, S.; Miyasaka, K.

    1999-01-01

    Purpose: To assess the efficacy and toxicity of small-field fractionated radiotherapy with or without stereotactic boost (SB) for vestibular schwannomas.Methods and materials: Thirty-nine patients with vestibular schwannoma were treated with irradiation between March 1991 and February 1996. Extra-meatal tumor diameters were under 30 mm. Thirty-three patients received small-field fractionated radiotherapy followed by SB. Basic dose schedule was 44 Gy in 22 fractions over 5 1/2 weeks plus 4 Gy in one session. Six patients received small-field fractionated radiotherapy only (40-44 Gy in 20-22 fractions over 5-5 1/2 weeks or 36 Gy in 20 fractions over 5 weeks).< Results: Follow-up ranged from 6 to 69 months (median, 24 months). Tumors decreased in size in 13 cases (33%), were unchanged in 25 (64%), and increased in one (3%). The actuarial 2-year tumor control rate was 97%. Fifteen patients had useful hearing (Gardner-Robertson class 1-2) and 25 patients had testable hearing (class 1-4) before irradiation. The 2-year actuarial rates of useful hearing preservation (free of deterioration from class 1-2 to class 3-5) were 78%. The 2-year actuarial rates of any testable hearing preservation (free of deterioration from class 1-4 to class 5) were 96%. No permanent facial and trigeminal neuropathy developed after irradiation. The 2-year actuarial incidences of facial and trigeminal neuropathies were 8% and 16%, respectively.Conclusions: Small-field fractionated radiotherapy with or without SB provides excellent short-term local control and a relatively low incidence of complications for vestibular schwannoma, although further follow-up is necessary to evaluate the long-term results. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  14. Nitrogen stabilization in organo-mineral fractions from soils with different land uses

    Science.gov (United States)

    Giannetta, Beatrice; Zaccone, Claudio; Rovira, Pere; Vischetti, Costantino; Plaza, César

    2017-04-01

    Understanding the processes that control quantity and quality of soil organic matter (SOM) interacting with mineral surfaces is of paramount importance. Although several physical fractionation methods have been proposed to date to obtain fractions that mirror SOM degree of stability and protection, a detailed quantification of stabilisation modes through which SOM bounds to the mineral matrix is still lacking. In this research we determined C and N distribution in several soils including coniferous and broadleaved forest soils, grassland soils, technosols and an agricultural soil amended with biochar at rates of 0 and 20 t/ha in a factorial combination with two types of organic amendment (municipal solid waste compost and sewage sludge). We performed a physical size fractionation by ultrasonic dispersion and wet sieving, splitting particles into four different size fractions: coarse sand (2000-200 µm diameter), fine sand (200-50 µm), coarse silt (50-20 µm) and fine silt plus clay (stabilization modes. This method, in fact, allows resolving the nature of different bonds between mineral and organic components by the use of sequential extractions with chemical reagents (potassium sulphate, sodium tetraborate, sodium pyrophosphate, sodium hydroxide, sodium hydroxide after weak acid attack, sodium hydroxide after sodium dithionite pretreatment, and sodium hydroxide after hydrofluoric acid pretreatments). Elemental analysis (CHN) was then carried out on SOM pools isolated from different fractions. Preliminary data show that, for all land uses in general, and for grassland soils in particular, most of the total N is found in organo-mineral complexes (fraction soil N content. Although a small N loss was observed during the fractionation procedure, especially in N-rich samples, and data analysis is still ongoing, these preliminary results could already represent a valuable insight into organic N stabilization by mineral matrix.

  15. Fractional variational calculus in terms of Riesz fractional derivatives

    International Nuclear Information System (INIS)

    Agrawal, O P

    2007-01-01

    This paper presents extensions of traditional calculus of variations for systems containing Riesz fractional derivatives (RFDs). Specifically, we present generalized Euler-Lagrange equations and the transversality conditions for fractional variational problems (FVPs) defined in terms of RFDs. We consider two problems, a simple FVP and an FVP of Lagrange. Results of the first problem are extended to problems containing multiple fractional derivatives, functions and parameters, and to unspecified boundary conditions. For the second problem, we present Lagrange-type multiplier rules. For both problems, we develop the Euler-Lagrange-type necessary conditions which must be satisfied for the given functional to be extremum. Problems are considered to demonstrate applications of the formulations. Explicitly, we introduce fractional momenta, fractional Hamiltonian, fractional Hamilton equations of motion, fractional field theory and fractional optimal control. The formulations presented and the resulting equations are similar to the formulations for FVPs given in Agrawal (2002 J. Math. Anal. Appl. 272 368, 2006 J. Phys. A: Math. Gen. 39 10375) and to those that appear in the field of classical calculus of variations. These formulations are simple and can be extended to other problems in the field of fractional calculus of variations

  16. Diameter of the thoracic and abdominal aorta in healthy Japanese

    International Nuclear Information System (INIS)

    Matsunaga, Wakako

    1989-01-01

    In 300 cases, diameter of thoracic and abdominal aorta in healthy Japanese is measured by computed tomography (CT) and the values are analyzed in relation to the age, sex and the level of the aorta on CT scan. Aorta becomes dilated with age. In female diameter of the aorta is correlated with age, on the other hand, diameter of those is not correlated with age in male. Diameter in male is larger than in female. Aorta tapers off and the ratio of tapering of the thoracic aorta is more prominent than that of the abdominal aorta. Therefore the calculations of the landmarks of tapering of the aorta and the ratio of diameter of the aorta to transverse diameter of the vertebral body at the levels of 10th thoracic and 3rd lumber vertebrae on CT scan are useful for judgement of normal range of diameter of the aorta. Calcifications of the wall of the aorta are seen initially at the age of 5th decade in the abdominal aorta and 6th decade in the thoracic aorta in healthy Japanese. They are noted in almost of the persons after the age of seventy years old. The presence of calcification is not correlated with diameter of the aorta at the same level on CT scan. (author)

  17. Small Diameter Bomb Increment II (SDB II)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-439 Small Diameter Bomb Increment II (SDB II) As of FY 2017 President’s Budget Defense... Bomb Increment II (SDB II) DoD Component Air Force Joint Participants Department of the Navy Responsible Office References SAR Baseline (Production...Mission and Description Small Diameter Bomb Increment II (SDB II) is a joint interest United States Air Force (USAF) and Department of the Navy

  18. Fractional Schroedinger equation

    International Nuclear Information System (INIS)

    Laskin, Nick

    2002-01-01

    Some properties of the fractional Schroedinger equation are studied. We prove the Hermiticity of the fractional Hamilton operator and establish the parity conservation law for fractional quantum mechanics. As physical applications of the fractional Schroedinger equation we find the energy spectra of a hydrogenlike atom (fractional 'Bohr atom') and of a fractional oscillator in the semiclassical approximation. An equation for the fractional probability current density is developed and discussed. We also discuss the relationships between the fractional and standard Schroedinger equations

  19. Fractional thermoelasticity

    CERN Document Server

    Povstenko, Yuriy

    2015-01-01

    This book is devoted to fractional thermoelasticity, i.e. thermoelasticity based on the heat conduction equation with differential operators of fractional order. Readers will discover how time-fractional differential operators describe memory effects and space-fractional differential operators deal with the long-range interaction. Fractional calculus, generalized Fourier law, axisymmetric and central symmetric problems and many relevant equations are featured in the book. The latest developments in the field are included and the reader is brought up to date with current research.  The book contains a large number of figures, to show the characteristic features of temperature and stress distributions and to represent the whole spectrum of order of fractional operators.  This work presents a picture of the state-of-the-art of fractional thermoelasticity and is suitable for specialists in applied mathematics, physics, geophysics, elasticity, thermoelasticity and engineering sciences. Corresponding sections of ...

  20. Structure of two-phase air-water flows. Study of average void fraction and flow patterns

    International Nuclear Information System (INIS)

    Roumy, R.

    1969-01-01

    This report deals with experimental work on a two phase air-water mixture in vertical tubes of different diameters. The average void fraction was measured in a 2 metre long test section by means of quick-closing valves. Using resistive probes and photographic techniques, we have determined the flow patterns and developed diagrams to indicate the boundaries between the various patterns: independent bubbles, agglomerated bubbles, slugs, semi-annular, annular. In the case of bubble flow and slug flow, it is shown that the relationship between the average void fraction and the superficial velocities of the phases is given by: V sg = f( ) * g(V sl ). The function g(V sl ) for the case of independent bubbles has been found to be: g(V sl ) = V sl + 20. For semi-annular and annular flow conditions; it appears that the average void fraction depends, to a first approximation only on the ratio V sg /V sl . (author) [fr

  1. Diameter measurements of polystyrene particles with atomic force microscopy

    International Nuclear Information System (INIS)

    Garnaes, J

    2011-01-01

    The size of (nano) particles is a key parameter used in controlling their function. The particle size is also important in order to understand their physical and chemical properties and regulate their number in health and safety issues. In this work, the geometric diameters of polystyrene spheres of nominal diameter 100 nm are measured using atomic force microscopy. The measurements are based on the apex height and on the average distance between neighbouring spheres when they form a close-packed monolayer on a flat mica substrate. The most important influence parameters for the determination of the geometric diameter are the lateral air gaps and deformation of the spheres. The lateral air gaps are caused by significant size variations of the individual spheres, and a correction is calculated based on the simulation of packing of spheres. The deformation of the spheres is caused mainly by capillary forces acting when they are in contact with each other or with the mica substrate. Based on calculated capillary forces and the literature values of the elastic properties of the polystyrene and mica, the deformation is estimated to be 2 nm with a standard uncertainty of 2 nm. The geometric diameter of the polystyrene spheres was measured with a combined standard uncertainty of ≈3 nm. The measured vertical diameter of 92.3 nm and the certified mobility equivalent diameter measured by differential mobility analysis (DMA) are marginally consistent at a confidence level of 95%. However, the measured lateral geometric diameter was 98.9 nm and is in good agreement with DMA

  2. Fractional quantum mechanics

    CERN Document Server

    Laskin, Nick

    2018-01-01

    Fractional quantum mechanics is a recently emerged and rapidly developing field of quantum physics. This is the first monograph on fundamentals and physical applications of fractional quantum mechanics, written by its founder. The fractional Schrödinger equation and the fractional path integral are new fundamental physical concepts introduced and elaborated in the book. The fractional Schrödinger equation is a manifestation of fractional quantum mechanics. The fractional path integral is a new mathematical tool based on integration over Lévy flights. The fractional path integral method enhances the well-known Feynman path integral framework. Related topics covered in the text include time fractional quantum mechanics, fractional statistical mechanics, fractional classical mechanics and the α-stable Lévy random process. The book is well-suited for theorists, pure and applied mathematicians, solid-state physicists, chemists, and others working with the Schrödinger equation, the path integral technique...

  3. Stochastic response of van der Pol oscillator with two kinds of fractional derivatives under Gaussian white noise excitation

    International Nuclear Information System (INIS)

    Yang Yong-Ge; Xu Wei; Sun Ya-Hui; Gu Xu-Dong

    2016-01-01

    This paper aims to investigate the stochastic response of the van der Pol (VDP) oscillator with two kinds of fractional derivatives under Gaussian white noise excitation. First, the fractional VDP oscillator is replaced by an equivalent VDP oscillator without fractional derivative terms by using the generalized harmonic balance technique. Then, the stochastic averaging method is applied to the equivalent VDP oscillator to obtain the analytical solution. Finally, the analytical solutions are validated by numerical results from the Monte Carlo simulation of the original fractional VDP oscillator. The numerical results not only demonstrate the accuracy of the proposed approach but also show that the fractional order, the fractional coefficient and the intensity of Gaussian white noise play important roles in the responses of the fractional VDP oscillator. An interesting phenomenon we found is that the effects of the fractional order of two kinds of fractional derivative items on the fractional stochastic systems are totally contrary. (paper)

  4. Research on deeply purifying effluent from uranium mining and metallurgy to remove uranium by ion exchange. Pt.2: Elution uranium from lower loaded uranium resin by the intense fractionation process

    International Nuclear Information System (INIS)

    Zhang Jianguo; Chen Shaoqiang; Qi Jing

    2002-01-01

    Developing macroporous resin for purifying uranium effluent from uranium mining and metallurgy is presented. The Intense Fractionation Process is employed to elute uranium from lower loaded uranium resin by the eluent of sulfuric acid and ammonium sulfate. The result is indicated that the uranium concentration in the rich elutriant is greatly increased, and the rich liquor is only one bed column volume, uranium concentration in the elutriant is increased two times which concentration is 10.1 g/L. The eluent is saved about 50% compared with the conventional fixed bed elution operation. And also the acidity in the rich elutriant is of benefit to the later precipitation process in uranium recovery

  5. Modelling diameter growth, mortality and recruitment of trees in ...

    African Journals Online (AJOL)

    Modelling diameter growth, mortality and recruitment of trees in miombo woodlands of Tanzania. ... Individual tree diameter growth and mortality models, and area-based recruitment models were developed. ... AJOL African Journals Online.

  6. Comprehensive approach to the assessment of nanosized fractions of polydisperse systems of crushed rocks

    Directory of Open Access Journals (Sweden)

    DANILOV Victor Evgenyevich

    2016-06-01

    Full Text Available The results of size determination for mechanically dispersed rock (polymineral sand, basalt based on methods of dynamic light scattering, gas (nitrogen sorption and electron microscopy were comparatively analyzed. The experimental samples are obtained by mechanical dispersion of raw materials on the planetary and colloidal grinding mills. There is a high correlation in the obtained experimental results. Method of dynamic light scattering makes it possible to analyze dimensional characteristics of polydispersed systems with high amount of nano- and submicron particles with sufficient sedimentation stability in the dispersion medium. Characteristics of particles size calculated by the specific surface area of the studied systems’ consider the content of the micro-size fraction. The effective diameter of the particles was proposed as the characteristics of their morphological structure. The calculation of the effective diameter is based on the particle mass.

  7. Definition of Beam Diameter for Electron Beam Welding

    Energy Technology Data Exchange (ETDEWEB)

    Burgardt, Paul [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pierce, Stanley W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dvornak, Matthew John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    It is useful to characterize the dimensions of the electron beam during process development for electron beam welding applications. Analysis of the behavior of electron beam welds is simplest when a single number can be assigned to the beam properties that describes the size of the beam spot; this value we generically call the “beam diameter”. This approach has worked well for most applications and electron beam welding machines with the weld dimensions (width and depth) correlating well with the beam diameter. However, in recent weld development for a refractory alloy, Ta-10W, welded with a low voltage electron beam machine (LVEB), it was found that the weld dimensions (weld penetration and weld width) did not correlate well with the beam diameter and especially with the experimentally determined sharp focus point. These data suggest that the presently used definition of beam diameter may not be optimal for all applications. The possible reasons for this discrepancy and a suggested possible alternative diameter definition is the subject of this paper.

  8. Development of measurement method of void fraction distribution on subcooled flow boiling using neutron radiography

    International Nuclear Information System (INIS)

    Kureta, Masatoshi; Matsubayashi, Masahito; Akimoto, Hajime

    1999-03-01

    In relation to the development of a solid target of high intensity neutron source, plasma-facing components of fusion reactor and so forth, it is indispensable to estimate the void fraction for high-heat-load subcooled flow boiling of water. Since the existing prediction method of void fraction is based on the database for tubes, it is necessary to investigate extendibility of the existing prediction method to narrow-gap rectangular channels that is used in the high-heat-load devices. However, measurement method of void fraction in the narrow-gap rectangular channel has not been established yet because of the difficulty of measurement. The objectives of this investigation are development of a new system for bubble visualization and void fraction measurement on subcooled flow boiling in narrow-gap rectangular channels using the neutron radiography, and establishment of void fraction database by using this measurement system. This report describes the void fraction measurement method by the neutron radiography technique, and summarizes the measured void fraction data in one-side heated narrow-gap rectangular channels at subcooled boiling condition. (author)

  9. Intensity stabilisation of optical pulse sequences for coherent control of laser-driven qubits

    Science.gov (United States)

    Thom, Joseph; Yuen, Ben; Wilpers, Guido; Riis, Erling; Sinclair, Alastair G.

    2018-05-01

    We demonstrate a system for intensity stabilisation of optical pulse sequences used in laser-driven quantum control of trapped ions. Intensity instability is minimised by active stabilisation of the power (over a dynamic range of > 104) and position of the focused beam at the ion. The fractional Allan deviations in power were found to be logic gates to be below 10^{-6} per gate.

  10. Diameter Tuning of Single-Walled Carbon Nanotubes by Diffusion Plasma CVD

    Directory of Open Access Journals (Sweden)

    Toshiaki Kato

    2011-01-01

    Full Text Available We have realized a diameter tuning of single-walled carbon nanotubes (SWNTs by adjusting process gas pressures with plasma chemical vapor deposition (CVD. Detailed photoluminescence measurements reveal that the diameter distribution of SWNTs clearly shifts to a large-diameter region with an increase in the pressure during plasma CVD, which is also confirmed by Raman scattering spectroscopy. Based on the systematical investigation, it is found that the main diameter of SWNTs is determined by the pressure during the heating in an atmosphere of hydrogen and the diameter distribution is narrowed by adjusting the pressure during the plasma generation. Our results could contribute to an application of SWNTs to high-performance thin-film transistors, which requires the diameter-controlled semiconductor-rich SWNTs.

  11. Fractional statistics and fractional quantized Hall effect

    International Nuclear Information System (INIS)

    Tao, R.; Wu, Y.S.

    1985-01-01

    The authors suggest that the origin of the odd-denominator rule observed in the fractional quantized Hall effect (FQHE) may lie in fractional statistics which govern quasiparticles in FQHE. A theorem concerning statistics of clusters of quasiparticles implies that fractional statistics do not allow coexistence of a large number of quasiparticles at fillings with an even denominator. Thus, no Hall plateau can be formed at these fillings, regardless of the presence of an energy gap. 15 references

  12. Collisionless energy absorption in the short-pulse intense laser-cluster interaction

    International Nuclear Information System (INIS)

    Kundu, M.; Bauer, D.

    2006-01-01

    In a previous paper [Phys. Rev. Lett. 96, 123401 (2006)] we have shown by means of three-dimensional particle-in-cell simulations and a simple rigid-sphere model that nonlinear resonance absorption is the dominant collisionless absorption mechanism in the intense, short-pulse laser cluster interaction. In this paper we present a more detailed account of the matter. In particular we show that the absorption efficiency is almost independent of the laser polarization. In the rigid-sphere model, the absorbed energy increases by many orders of magnitude at a certain threshold laser intensity. The particle-in-cell results display maximum fractional absorption around the same intensity. We calculate the threshold intensity and show that it is underestimated by the common overbarrier ionization estimate

  13. Soil biological activity as affected by tillage intensity

    Science.gov (United States)

    Gajda, A. M.; Przewłoka, B.

    2012-02-01

    The effect of tillage intensity on changes of microbiological activity and content of particulate organic matter in soil under winter wheat duirng 3 years was studied. Microbial response related to the tillage-induced changes in soil determined on the content of biomass C and N, the rate of CO2 evolution, B/F ratio, the activity of dehydrogenases, acid and alkaline phosphatases, soil C/N ratio and microbial biomass C/N ratio confirmed the high sensitivity of soil microbial populations to the tillage system applied. After three year studies, the direct sowing system enhanced the increase of labile fraction of organic matter content in soil. There were no significant changes in the labile fraction quantity observed in soil under conventional tillage. Similar response related to the tillage intensity was observed in particulate organic matter quantities expressed as a percentage of total organic matter in soil. A high correlation coefficients calculated between contents of soil microbial biomass C and N, particulate organic matter and potentially mineralizable N, and the obtained yields of winter wheat grown on experimental fields indicated on a high importance of biological quality of status of soil for agricultural crop production.

  14. Granular flow through an aperture: Influence of the packing fraction

    Science.gov (United States)

    Aguirre, M. A.; De Schant, R.; Géminard, J.-C.

    2014-07-01

    For the last 50 years, the flow of a granular material through an aperture has been intensely studied in gravity-driven vertical systems (e.g., silos and hoppers). Nevertheless, in many industrial applications, grains are horizontally transported at constant velocity, lying on conveyor belts or floating on the surface of flowing liquids. Unlike fluid flows, that are controlled by the pressure, granular flow is not sensitive to the local pressure but rather to the local velocity of the grains at the outlet. We can also expect the flow rate to depend on the local density of the grains. Indeed, vertical systems are packed in dense configurations by gravity, but, in contrast, in horizontal systems the density can take a large range of values, potentially very small, which may significantly alter the flow rate. In the present article, we study, for different initial packing fractions, the discharge through an orifice of monodisperse grains driven at constant velocity by a horizontal conveyor belt. We report how, during the discharge, the packing fraction is modified by the presence of the outlet, and we analyze how changes in the packing fraction induce variations in the flow rate. We observe that variations of packing fraction do not affect the velocity of the grains at the outlet, and, therefore, we establish that flow-rate variations are directly related to changes in the packing fraction.

  15. Effect of Varying Hemodynamic and Vascular Conditions on Fractional Flow Reserve: An In Vitro Study.

    Science.gov (United States)

    Kolli, Kranthi K; Min, James K; Ha, Seongmin; Soohoo, Hilary; Xiong, Guanglei

    2016-06-30

    The aim of this study was to investigate the impact of varying hemodynamic conditions on fractional flow reserve (ratio of pressure distal [Pd] and proximal [Pa] to stenosis under hyperemia) in an in vitro setting. Failure to achieve maximal hyperemia and the choice of hyperemic agents may have differential effects on coronary hemodynamics and, consequently, on the determination of fractional flow reserve. An in vitro flow system was developed to experimentally model the physiological coronary circulation as flow-dependent stenosis resistance in series with variable downstream resistance. Five idealized models with 30% to 70% diameter stenosis severity were fabricated using VeroClear rigid material in an Objet260 Connex printer. Mean aortic pressure was maintained at 7 levels (60-140 mm Hg) from hypotension to hypertension using a needle valve that mimicked adjustable microcirculatory resistance. A range of physiological flow rates was applied by a steady flow pump and titrated by a flow sensor. The pressure drop and the pressure ratio (Pd/Pa) were assessed for the 7 levels of aortic pressure and differing flow rates. The in vitro experimental data were coupled with pressure-flow relationships from clinical data for populations with and without myocardial infarction, respectively, to evaluate fractional flow reserve. The curve for pressure ratio and flow rate demonstrated a quadratic relationship with a decreasing slope. The absolute decrease in fractional flow reserve in the group without myocardial infarction (with myocardial infarction) was on the order of 0.03 (0.02), 0.05 (0.02), 0.07 (0.05), 0.17 (0.13) and 0.20 (0.24), respectively, for 30%, 40%, 50%, 60%, and 70% diameter stenosis, for an increase in aortic pressure from 60 to 140 mm Hg. The fractional flow reserve value, an index of physiological stenosis significance, was observed to decrease with increasing aortic pressure for a given stenosis in this idealized in vitro experiment for vascular

  16. Tempered fractional calculus

    Energy Technology Data Exchange (ETDEWEB)

    Sabzikar, Farzad, E-mail: sabzika2@stt.msu.edu [Department of Statistics and Probability, Michigan State University, East Lansing, MI 48823 (United States); Meerschaert, Mark M., E-mail: mcubed@stt.msu.edu [Department of Statistics and Probability, Michigan State University, East Lansing, MI 48823 (United States); Chen, Jinghua, E-mail: cjhdzdz@163.com [School of Sciences, Jimei University, Xiamen, Fujian, 361021 (China)

    2015-07-15

    Fractional derivatives and integrals are convolutions with a power law. Multiplying by an exponential factor leads to tempered fractional derivatives and integrals. Tempered fractional diffusion equations, where the usual second derivative in space is replaced by a tempered fractional derivative, govern the limits of random walk models with an exponentially tempered power law jump distribution. The limiting tempered stable probability densities exhibit semi-heavy tails, which are commonly observed in finance. Tempered power law waiting times lead to tempered fractional time derivatives, which have proven useful in geophysics. The tempered fractional derivative or integral of a Brownian motion, called a tempered fractional Brownian motion, can exhibit semi-long range dependence. The increments of this process, called tempered fractional Gaussian noise, provide a useful new stochastic model for wind speed data. A tempered fractional difference forms the basis for numerical methods to solve tempered fractional diffusion equations, and it also provides a useful new correlation model in time series.

  17. Tempered fractional calculus

    Science.gov (United States)

    Sabzikar, Farzad; Meerschaert, Mark M.; Chen, Jinghua

    2015-07-01

    Fractional derivatives and integrals are convolutions with a power law. Multiplying by an exponential factor leads to tempered fractional derivatives and integrals. Tempered fractional diffusion equations, where the usual second derivative in space is replaced by a tempered fractional derivative, govern the limits of random walk models with an exponentially tempered power law jump distribution. The limiting tempered stable probability densities exhibit semi-heavy tails, which are commonly observed in finance. Tempered power law waiting times lead to tempered fractional time derivatives, which have proven useful in geophysics. The tempered fractional derivative or integral of a Brownian motion, called a tempered fractional Brownian motion, can exhibit semi-long range dependence. The increments of this process, called tempered fractional Gaussian noise, provide a useful new stochastic model for wind speed data. A tempered fractional difference forms the basis for numerical methods to solve tempered fractional diffusion equations, and it also provides a useful new correlation model in time series.

  18. Tempered fractional calculus

    International Nuclear Information System (INIS)

    Sabzikar, Farzad; Meerschaert, Mark M.; Chen, Jinghua

    2015-01-01

    Fractional derivatives and integrals are convolutions with a power law. Multiplying by an exponential factor leads to tempered fractional derivatives and integrals. Tempered fractional diffusion equations, where the usual second derivative in space is replaced by a tempered fractional derivative, govern the limits of random walk models with an exponentially tempered power law jump distribution. The limiting tempered stable probability densities exhibit semi-heavy tails, which are commonly observed in finance. Tempered power law waiting times lead to tempered fractional time derivatives, which have proven useful in geophysics. The tempered fractional derivative or integral of a Brownian motion, called a tempered fractional Brownian motion, can exhibit semi-long range dependence. The increments of this process, called tempered fractional Gaussian noise, provide a useful new stochastic model for wind speed data. A tempered fractional difference forms the basis for numerical methods to solve tempered fractional diffusion equations, and it also provides a useful new correlation model in time series

  19. Controlled growth of well-aligned carbon nanotubes with large diameters

    Science.gov (United States)

    Wang, Xianbao; Liu, Yunqi; Zhu, Daoben

    2001-06-01

    Well-aligned carbon nanotubes (CNTs) with large diameters (25-200 nm) were synthesized by pyrolysis of iron(II) phthalocyanine. The outer diameter up to 218.5 nm and the length of the well-aligned CNTs can be systematically controlled by varying the growth time. A tube-in-tube nano-structure with large and small diameters of 176 and 16.7 nm, respectively, was found. The grain sizes of the iron catalyst play an important role in controlling the CNT diameters. These results are of great importance to design new aligned CNT-based electron field emitters in the potential application of panel displays.

  20. Fractional Vector Calculus and Fractional Special Function

    OpenAIRE

    Li, Ming-Fan; Ren, Ji-Rong; Zhu, Tao

    2010-01-01

    Fractional vector calculus is discussed in the spherical coordinate framework. A variation of the Legendre equation and fractional Bessel equation are solved by series expansion and numerically. Finally, we generalize the hypergeometric functions.

  1. Preparatory research for development of a capacitance sensor monitoring the liquid fraction in an inclined pipe

    International Nuclear Information System (INIS)

    Ko, Min Seok; Lee, Bo An; Kim, Sin; Yun, Byong Jo

    2012-01-01

    Two phase flow is a highly general phenomenon in various engineering fields including thermal hydraulic systems of the nuclear power plant. In particular, the liquid fraction in two phase system is one of the most important parameters to be considered for efficient system design and analysis. There have been various methods for the liquid fraction measurement. Wojtan et al. employed an optical fiber for liquid fraction measurement. Elbow and Rezkallah adopted the capacitance signal, Tsochatzidis et al. and Fossa used the conductance response in order to monitor the liquid fraction in various two phase flow regimes. The electrical methods are based on the fact that the liquid and gas have different conductivity and permittivity values, and these electrical properties directly correspond to phase distributions. In the capacitance method, in particular, one or more pairs of electrodes attached inside or outside the pipe wall measure the capacitance between electrode pairs and this measured capacitance signal is directly converted to the liquid fraction. In this work, as a preparatory research for development of a capacitance sensor monitoring the liquid fraction in an inclined pipe whose diameter and inclination angle are 45mm and 3rad, respectively, a capacitance is designed. Also, data evaluation procedures of a wire mesh sensor which would be employed for the verification of capacitance sensor performance are verified by comparing static experiments

  2. Elemental fractionation in 785 nm picosecond and femtosecond laser ablation inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Shaheen, M.E., E-mail: mshaheen73@science.tanta.edu.eg [Department of Physics, Faculty of Sciences, Tanta University, Tanta (Egypt); Gagnon, J.E.; Fryer, B.J. [Great Lakes Institute for Environmental Research (GLIER), University of Windsor, Windsor, Ontario N9B 3P4 (Canada); Department of Earth and Environmental Sciences, University of Windsor, Windsor, Ontario N9B 3P4 (Canada)

    2015-05-01

    Elemental fractionation and ICP-MS signal response were investigated for two different pulse width laser beams originating from the same laser system. Femtosecond and picosecond laser beams at pulse widths of 130 fs and 110 ps, respectively, and wavelength of 785 nm were used to ablate NIST 610 synthetic glass and SRM 1107 Naval Brass B at the same spot for 800 to 1000 laser pulses at different repetition rates (5 to 50 Hz). Elemental fractionation was found to depend on repetition rate and showed a trend with femtosecond laser ablation that is opposite to that observed in picosecond laser ablation for most measured isotopes. ICP-MS signal intensity was higher in femtosecond than picosecond LA-ICP-MS in both NIST 610 and naval brass when ablation was conducted under the same fluence and repetition rate. The differences in signal intensity were partly related to differences in particle size distribution between particles generated by femtosecond and picosecond laser pulses and the consequent differences in transport and ionization efficiencies. The main reason for the higher signal intensity resulting from femtosecond laser pulses was related to the larger crater sizes compared to those created during picosecond laser ablation. Elemental ratios measured using {sup 66}Zn/{sup 63}Cu, {sup 208}Pb/{sup 238}U, {sup 232}Th/{sup 238}U, {sup 66}Zn/{sup 232}Th and {sup 66}Zn/{sup 208}Pb were found to change with the number of laser pulses with data points being more scattered in picosecond than femtosecond laser pulses. Reproducibility of replicate measurements of signal intensities, fractionation and elemental ratios was better for fs-LA-ICP-MS (RSD ~ 3 to 6%) than ps-LA-ICP-MS (RSD ~ 7 to 11%). - Highlights: • Fractionation and ICP-MS signal response were investigated for two different pulse widths using NIST 610 and Naval Brass. • Dependence of fractionation indices on repetition rate and pulse width. • Higher ablation rate was observed in picosecond compared to

  3. Diameter modulation of vertically aligned single-walled carbon nanotubes.

    Science.gov (United States)

    Xiang, Rong; Einarsson, Erik; Murakami, Yoichi; Shiomi, Junichiro; Chiashi, Shohei; Tang, Zikang; Maruyama, Shigeo

    2012-08-28

    We demonstrate wide-range diameter modulation of vertically aligned single-walled carbon nanotubes (SWNTs) using a wet chemistry prepared catalyst. In order to ensure compatibility to electronic applications, the current minimum mean diameter of 2 nm for vertically aligned SWNTs is challenged. The mean diameter is decreased to about 1.4 nm by reducing Co catalyst concentrations to 1/100 or by increasing Mo catalyst concentrations by five times. We also propose a novel spectral analysis method that allows one to distinguish absorbance contributions from the upper, middle, and lower parts of a nanotube array. We use this method to quantitatively characterize the slight diameter change observed along the array height. On the basis of further investigation of the array and catalyst particles, we conclude that catalyst aggregation-rather than Ostwald ripening-dominates the growth of metal particles.

  4. Porosity Assessment for Different Diameters of Coir Lignocellulosic Fibers

    Science.gov (United States)

    da Luz, Fernanda Santos; Paciornik, Sidnei; Monteiro, Sergio Neves; da Silva, Luiz Carlos; Tommasini, Flávio James; Candido, Verônica Scarpini

    2017-10-01

    The application of natural lignocellulosic fibers (LCFs) in engineering composites has increased interest in their properties and structural characteristics. In particular, the inherent porosity of an LCF markedly affects its density and the adhesion to polymer matrices. For the first time, both open and closed porosities of a natural LCF, for different diameter ranges, were assessed. Fibers extracted from the mesocarp of the coconut fruit were investigated by nondestructive methods of density measurements and x-ray microtomography (microCT). It was found that, for all diameter ranges, the closed porosity is significantly higher than the open porosity. The total porosity increases with diameter to around 60% for coir fibers with more than 503 μm in diameter. The amount and characteristics of these open and closed porosities were revealed by t test and Weibull statistics as well as by microCT.

  5. Deriving muscle fiber diameter from recorded single fiber potential.

    Science.gov (United States)

    Zalewska, Ewa

    2017-12-01

    The aim of the study was to estimate muscle fiber diameters through analysis of single muscle fiber potentials (SFPs) recorded in the frontalis muscle of a healthy subject. Our previously developed analytical and graphic method to derive fiber diameter from the analysis of the negative peak duration and the amplitude of SFP, was applied to a sample of ten SFPs recorded in vivo. Muscle fiber diameters derived from the simulation method for the sample of frontalis muscle SFPs are consistent with anatomical data for this muscle. The results confirm the utility of proposed simulation method. Outlying data could be considered as the result of a contribution of other fibers to the potential recorded using an SFEMG electrode. Our graphic tool provides a rapid estimation of muscle fiber diameter. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Axon diameter mapping in crossing fibers with diffusion MRI

    DEFF Research Database (Denmark)

    Zhang, Hui; Dyrby, Tim B; Alexander, Daniel C

    2011-01-01

    This paper proposes a technique for a previously unaddressed problem, namely, mapping axon diameter in crossing fiber regions, using diffusion MRI. Direct measurement of tissue microstructure of this kind using diffusion MRI offers a new class of biomarkers that give more specific information about...... tissue than measures derived from diffusion tensor imaging. Most existing techniques for axon diameter mapping assume a single axon orientation in the tissue model, which limits their application to only the most coherently oriented brain white matter, such as the corpus callosum, where the single...... model to enable axon diameter mapping in voxels with crossing fibers. We show in simulation that the technique can provide robust axon diameter estimates in a two-fiber crossing with the crossing angle as small as 45 degrees. Using ex vivo imaging data, we further demonstrate the feasibility...

  7. Fractional Hopfield Neural Networks: Fractional Dynamic Associative Recurrent Neural Networks.

    Science.gov (United States)

    Pu, Yi-Fei; Yi, Zhang; Zhou, Ji-Liu

    2017-10-01

    This paper mainly discusses a novel conceptual framework: fractional Hopfield neural networks (FHNN). As is commonly known, fractional calculus has been incorporated into artificial neural networks, mainly because of its long-term memory and nonlocality. Some researchers have made interesting attempts at fractional neural networks and gained competitive advantages over integer-order neural networks. Therefore, it is naturally makes one ponder how to generalize the first-order Hopfield neural networks to the fractional-order ones, and how to implement FHNN by means of fractional calculus. We propose to introduce a novel mathematical method: fractional calculus to implement FHNN. First, we implement fractor in the form of an analog circuit. Second, we implement FHNN by utilizing fractor and the fractional steepest descent approach, construct its Lyapunov function, and further analyze its attractors. Third, we perform experiments to analyze the stability and convergence of FHNN, and further discuss its applications to the defense against chip cloning attacks for anticounterfeiting. The main contribution of our work is to propose FHNN in the form of an analog circuit by utilizing a fractor and the fractional steepest descent approach, construct its Lyapunov function, prove its Lyapunov stability, analyze its attractors, and apply FHNN to the defense against chip cloning attacks for anticounterfeiting. A significant advantage of FHNN is that its attractors essentially relate to the neuron's fractional order. FHNN possesses the fractional-order-stability and fractional-order-sensitivity characteristics.

  8. Demineralized water flow cancelling experiments with ice plug into high diameter horizontal tube (300 nominal diameter)

    International Nuclear Information System (INIS)

    Gyongyosi, T.; Valeca, S.; Corbescu, B.; Puiu, D.; Panaitescu, V. N.

    2015-01-01

    The isolation with ice plug of a high diameter horizontal pipeline section is a specific technique for repairs activities/ replacements of components owning to thermo-hydraulic installations working with liquid agents. The application of such technique don.t assumes stopping of the entire system. The ice plugging inside of the pipeline assumes using of a special device and of an own specific technology for application. The paper contains a brief description of the experimental technological facilities used, followed by setting off the main moments in evolution of two experimental tests carried out on the test section with 300 mm nominal diameter for demineralized water and, finally, by a brief results analysis and some conclusions. The paper is dedicated to the specialists working in the research and technological engineering. (authors)

  9. Contraction intensity and feeding affect collagen and myofibrillar protein synthesis rates differently in human skeletal muscle

    DEFF Research Database (Denmark)

    Holm, Lars; Hall, Gerrit van; Rose, Adam John

    2010-01-01

    Exercise stimulates muscle protein fractional synthesis rate (FSR) but the importance of contractile intensity and whether it interplays with feeding is not understood. This was investigated following two distinct resistance exercise (RE) contraction intensities using an intra-subject design...... to feeding. Further, although functionally linked, the contractile and the supportive matrix structures upregulate their protein synthesis rate quite differently in response to feeding and contractile-activity and -intensity....

  10. Isotopic fractionation and profile evolution of a melting snowcover

    Institute of Scientific and Technical Information of China (English)

    周石硚; 中尾正义; 桥本重将; 坂井亚规子; 成田英器; 石川信敬

    2001-01-01

    Successive snow pits were dug intensively in a melting snowcover. Water was successfully separated from snow grains in the field for the first time. By measuring δ18O values of water and snow grain samples as well as comparing isotopic profiles, it is found that meltwater percolating down in snow develops quick and clear isotopic fractionation with snow grains, but exerts no clear impact on the δ18O profile of the snowcover through which the meltwater percolates.

  11. Study of tube diameter effect on the burnout

    International Nuclear Information System (INIS)

    Levitan, L.L.; Lantsman, F.P.; Dedneva, E.I.

    1981-01-01

    Effect of a tube diameter d on boundary steam content Xsub(b) is experimentally investigated during unwashed liquid wall film drying in the disperse-ring flow regime. For this purpose systematical experimental investigations of the burnout of the second kind in tubes with diameters of 4, 6 and 12 mm have been carried out as well as the other data relating to burnout in tubes with diameter from 4 to 40 mm are used. The investigations have been carried out at water and steam pressures of 4.9-13.7 MPa and mass velocities from 750 to 5000 kg/m 2 xs. It is elucidated that increase in the tube diameter results in reducing the ranges of pressures and mass velocities at which Xsub(b) is independent of heat flux. Quantity dependence Xsub(b)=f(d) has been obtained as well. The best agreement with data from different experiments is observed when taking into account the effect of d on Xsub(b) by means of the following relation: Xsub(b) is proportional to dsup(-0.25). In this case divergence, as a rule, does not exceed 10% [ru

  12. Misonidazole in fractionated radiotherapy: are many small fractions best

    International Nuclear Information System (INIS)

    Denekamp, J.; McNally, N.J.; Fowler, J.F.; Joiner, M.C.

    1980-01-01

    The largest sensitizing effect is always demonstrated with six fractions, each given with 2 g/m 2 of misonidazole. In the absence of reoxygenation a sensitizer enhancement ratio of 1.7 is predicted, but this falls to 1.1-1.2 if extensive reoxygenation occurs. Less sensitization is observed with 30 fractions, each with 0.4 g/m 2 of drug. However, for clinical use, the important question is which treatment kills the maximum number of tumour cells. Many of the simulations predict a marked disadvantage of reducing the fraction number for X rays alone. The circumstances in which this disadvantage is offset by the large Sensitizer enhancement ratio values with a six-fraction schedule are few. The model calculations suggest that many small fractions, each with a low drug dose, are safest unless the clinician has some prior knowledge that a change in fraction number is not disadvantageous. (author)

  13. Fractional dynamic calculus and fractional dynamic equations on time scales

    CERN Document Server

    Georgiev, Svetlin G

    2018-01-01

    Pedagogically organized, this monograph introduces fractional calculus and fractional dynamic equations on time scales in relation to mathematical physics applications and problems. Beginning with the definitions of forward and backward jump operators, the book builds from Stefan Hilger’s basic theories on time scales and examines recent developments within the field of fractional calculus and fractional equations. Useful tools are provided for solving differential and integral equations as well as various problems involving special functions of mathematical physics and their extensions and generalizations in one and more variables. Much discussion is devoted to Riemann-Liouville fractional dynamic equations and Caputo fractional dynamic equations.  Intended for use in the field and designed for students without an extensive mathematical background, this book is suitable for graduate courses and researchers looking for an introduction to fractional dynamic calculus and equations on time scales. .

  14. Ablative fractional laser enhances MAL-induced PpIX accumulation

    DEFF Research Database (Denmark)

    Haak, C S; Christiansen, K; Erlendsson, Andrés M

    2016-01-01

    BACKGROUND AND OBJECTIVES: Pretreatment of skin with ablative fractional laser enhances accumulation of topical provided photosensitizer, but essential information is lacking on the interaction between laser channel densities and pharmacokinetics. Hence our objectives were to investigate how...... (range 46-133min) induced fluorescence levels similar to curettage and 180min incubation. Furthermore, MAL 80 and 160mg/g induced similar fluorescence intensities in skin exposed to laser densities of 1, 2 and 5% (p>0.0537, 30-180min). CONCLUSION: MAL-induced protoporphyrin accumulation is augmented...... protoporphyrin accumulation was affected by laser densities, incubation time and drug concentration. METHODS: We conducted the study on the back of healthy male volunteers (n=11). Test areas were pretreated with 2940nm ablative fractional Er:YAG laser, 11.2mJ per laser channel using densities of 1, 2, 5, 10...

  15. Maximizing therapeutic gain with gemcitabine and fractionated radiation

    International Nuclear Information System (INIS)

    Mason, Kathy A.; Milas, Luka; Hunter, Nancy R.; Elshaikh, Mohamed; Buchmiller, Lara; Kishi, Kazushi; Hittelman, K. Walter; Ang, K. Kian

    1999-01-01

    Purpose/Objective: The nucleoside analogue gemcitabine inhibits cellular repair and repopulation, induces apoptosis, causes tumor growth delay, and enhances radiation-induced growth delay. After single doses of drug and radiation, maximum enhancement of tumor response was obtained when gemcitabine preceded radiation by at least 24 h. Conversely, the cellular radioresponse of the normal gastrointestinal epithelium was slightly protected when gemcitabine and radiation were separated by 24 h. This differential response created a time frame within which therapeutic gain could be maximized. In our present investigation, we sought to define the most therapeutically beneficial scheme of gemcitabine administration when combined with fractionated radiotherapy. Methods and Materials: C3Hf/Kam mice were given identical drug and radiation schedules of administration, and both normal tissue (jejunal mucosa) and tumor (Sa-NH) responses were measured. Irradiation was given once per day for 5 days in normal tissue and tumor growth delay studies and twice per day for the tumor cure endpoint. A total dose of 25 mg/kg gemcitabine was given i.p. in 1 of 3 schedules: a single dose of 25 mg/kg 24 h before the start of fractionated irradiation, 12.5 mg/kg 24 h before the first and third radiation doses, or 24 h before each of 5 radiation doses. Groups of mice bearing 7- or 8-mm diameter tumors were treated with gemcitabine alone or in combination with fractionated irradiation under ambient or hypoxic conditions. The survival response of the jejunal mucosa was quantified by the microcolony assay and histologically by quantifying apoptosis, mitosis, S-phase fraction, and crypt cellularity. Results: For tumor growth delay, dose-modifying factors (DMFs) were similar (1.34-1.46) for all 3 schedules of drug administration. In contrast, the response of the jejunum was strongly dependent on the schedule of gemcitabine administration. A single dose of gemcitabine before the start of fractionated

  16. Stereotactic Fractionated Radiotherapy and LINAC Radiosurgery in the Treatment of Vestibular Schwannoma-Report About Both Stereotactic Methods From a Single Institution

    International Nuclear Information System (INIS)

    Kopp, Christine; Fauser, Claudius; Mueller, Axel; Astner, Sabrina T.; Jacob, Vesna; Lumenta, Christianto; Meyer, Bernhard; Tonn, Joerg-Christian; Molls, Michael; Grosu, Anca-Ligia

    2011-01-01

    Purpose: To evaluate tumor control and side effects associated with radiosurgery (RS) and stereotactic fractionated radiotherapy (SFR) for vestibular schwannomas (VSs) in a group of patients treated at the same institution. Methods and Materials: Between May 1997 and June 2007, 115 consecutive cases of VS were treated in our department. The SFR group (47 patients), including larger tumors (maximum diameter >1.5 cm), received a total dose of 54 Gy at 1.8 Gy per fraction. The RS group (68 patients, maximum diameter <1.5 cm) received a total dose of 12 Gy at the 100% isodose. Evaluation included serial imaging tests (magnetic resonance imaging) and neurologic and functional hearing examinations. Results: The tumor control rate was 97.9% in the SFR group for a mean follow-up time of 32.1 months and 98.5% in the RS group for a mean follow-up time of 30.1 months. Hearing function was preserved after RS in 85% of the patients and after SFR in 79%. Facial and trigeminal nerve function remained mostly unaffected after SFR. After RS, new trigeminal neuropathy occurred in 9 of 68 patients (13%). Conclusions: A high tumor control rate and low number of side effects are registered after SFR and RS of VS. These results confirm that considering tumor diameter, both RS and SFR are good treatment modalities for VS.

  17. Fractional gradient and its application to the fractional advection equation

    OpenAIRE

    D'Ovidio, M.; Garra, R.

    2013-01-01

    In this paper we provide a definition of fractional gradient operators, related to directional derivatives. We develop a fractional vector calculus, providing a probabilistic interpretation and mathematical tools to treat multidimensional fractional differential equations. A first application is discussed in relation to the d-dimensional fractional advection-dispersion equation. We also study the connection with multidimensional L\\'evy processes.

  18. Fractionation of Pb and Cu in the fine fraction (landfill.

    Science.gov (United States)

    Kaczala, Fabio; Orupõld, Kaja; Augustsson, Anna; Burlakovs, Juris; Hogland, Marika; Bhatnagar, Amit; Hogland, William

    2017-11-01

    The fractionation of metals in the fine fraction (landfill was carried out to evaluate the metal (Pb and Cu) contents and their potential towards not only mobility but also possibilities of recovery/extraction. The fractionation followed the BCR (Community Bureau of Reference) sequential extraction, and the exchangeable (F1), reducible (F2), oxidizable (F3) and residual fractions were determined. The results showed that Pb was highly associated with the reducible (F2) and oxidizable (F3) fractions, suggesting the potential mobility of this metal mainly when in contact with oxygen, despite the low association with the exchangeable fraction (F1). Cu has also shown the potential for mobility when in contact with oxygen, since high associations with the oxidizable fraction (F3) were observed. On the other hand, the mobility of metals in excavated waste can be seen as beneficial considering the circular economy and recovery of such valuables back into the economy. To conclude, not only the total concentration of metals but also a better understanding of fractionation and in which form metals are bound is very important to bring information on how to manage the fine fraction from excavated waste both in terms of environmental impacts and also recovery of such valuables in the economy.

  19. Divergent biparietal diameter growth rates in twin pregnancies.

    Science.gov (United States)

    Houlton, M C

    1977-05-01

    Twenty-eight twin pregnancies were monitored by serial ultrasonic cephalometry from 30 or 31 weeks' gestation. The rates of growth of the individual twins as determined by biparietal diameters were similar in 11 cases (39%) and divergent in 17 (61%). When the rates of growth were divergent, the lesser rate was always below the mean for singleton pregnancies, and the incidence of small-for-gestational-age babies was 18 of 34 (53%). It was apparent that the greater the difference in biparietal diameters within the 2 weeks preceding delivery, the higher the risk of a small-for-gestation-age baby being delivered. No comment could be made on the growth rate prior to 28 weeks except that at diagnosis there was little or no difference in biparietal diameters.

  20. Sex Dimorphism of the Heart Diameters and Cardiothoracic Ratios ...

    African Journals Online (AJOL)

    Objective: To determine gender associated differences in the cardiothoracic ratio (CTR) and heart diameters in a normal Nigerian population. Subject and Method: The normal heart diameters and cardiothoracic ratios were measured from posteroanterior (PA) chest radiographs of healthy 510 male and 508 female ...

  1. Not traditional regimes of radiotherapeutic dose fractionation as modifier of radiotherapy for carcinoma of lungs

    International Nuclear Information System (INIS)

    Artemova, N.A.

    2008-01-01

    The efficiency of applying various of radiotherapeutic dose fractionation was analyzed. The results of the own studies performed at the Scientific and Research Institute of Oncology and Medical Radiology for elaborating not traditional regimes of radiotherapeutic dose fractionation (a dynamic fractionation applying enlarged regimes at the first stage and the classic ones at the second stage) were presented. Appliance of the modified radiotherapy for the epidermoid carcinoma of the lungs allowed to increase the objective response from 45,3+-3% to 80+-5% the tumor disappearing completely in 40+-6% of patients as compared with 10+-2%. Appliance of the intensive not traditional variant of the radiotherapy dynamic fractionation in case of a small cell carcinoma of the lungs resulted in the therapy duration reduction from 6 to 4 weeks. Thus the not traditional dose fractionation might become a mechanism for the improving the radiotherapy of persons suffering from the carcinoma of the lungs. (authors)

  2. Void fraction for gas bubbling in shallow viscous pools-application to molten core concrete interaction

    International Nuclear Information System (INIS)

    Journeau, C.; Haquet, J.F.

    2005-01-01

    During Molten Core-Concrete Interaction, the concrete will release gases (mainly steam and carbon oxides) that will flow through the corium pool. To obtain reliable heat transfer prediction, it is necessary to model the void fraction in the pool as a function of the gas mass flow (or superficial velocity at the interface). A series of simulant-materials have been performed with water-air and sugar syrup-air in order to study how the drift model could be applied to a shallow pool (where the bubbly flow is not fully developed) and to liquids which are more viscous (with higher Morton numbers) than water. The bubble average diameter was estimated around 3 mm with spherical to ellipsoidal shapes. For all the configurations, even with the shallowest pools (6 cm height for 38 cm diameter) the experimental void fractions follow the drift-model relationship. In water, the distribution coefficient C 0 tends to the classical value of 1.2 while the drift velocity V jg tends to the 23 cm/s predicted by Ishii (1975) model for churn flows. For the more viscous syrup, the drift velocity tends to 13 cm/s which is significantly lower than the value obtained from the Ishii correlation for bubbly or churn flows (established for water). These results are then applied to MCCI experimental configurations. (authors)

  3. Two-group modeling of interfacial area transport in large diameter channels

    Energy Technology Data Exchange (ETDEWEB)

    Schlegel, J.P., E-mail: schlegelj@mst.edu [Department of Mining and Nuclear Engineering, Missouri University of Science and Technology, 301 W 14th St., Rolla, MO 65409 (United States); Hibiki, T.; Ishii, M. [School of Nuclear Engineering, Purdue University, 400 Central Dr., West Lafayette, IN 47907 (United States)

    2015-11-15

    Highlights: • Implemented updated constitutive models and benchmarking method for IATE in large pipes. • New model and method with new data improved the overall IATE prediction for large pipes. • Not all conditions well predicted shows that further development is still required. - Abstract: A comparison of the existing two-group interfacial area transport equation source and sink terms for large diameter channels with recently collected interfacial area concentration measurements (Schlegel et al., 2012, 2014. Int. J. Heat Fluid Flow 47, 42) has indicated that the model does not perform well in predicting interfacial area transport outside of the range of flow conditions used in the original benchmarking effort. In order to reduce the error in the prediction of interfacial area concentration by the interfacial area transport equation, several constitutive relations have been updated including the turbulence model and relative velocity correlation. The transport equation utilizing these updated models has been modified by updating the inter-group transfer and Group 2 coalescence and disintegration kernels using an expanded range of experimental conditions extending to pipe sizes of 0.304 m [12 in.], gas velocities of up to nearly 11 m/s [36.1 ft/s] and liquid velocities of up to 2 m/s [6.56 ft/s], as well as conditions with both bubbly flow and cap-bubbly flow injection (Schlegel et al., 2012, 2014). The modifications to the transport equation have resulted in a decrease in the RMS error for void fraction and interfacial area concentration from 17.32% to 12.3% and 21.26% to 19.6%. The combined RMS error, for both void fraction and interfacial area concentration, is below 15% for most of the experiments used in the comparison, a distinct improvement over the previous version of the model.

  4. Radiobiology of hypofractionated stereotactic radiotherapy: what are the optimal fractionation schedules?

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Miyakawa, Akifumi; Otsuka, Shinya; Iwata, Hiromitsu

    2016-01-01

    In hypofractionated stereotactic radiotherapy (SRT), high doses per fraction are usually used and the dose delivery pattern is different from that of conventional radiation. The daily dose is usually given intermittently over a longer time compared with conventional radiotherapy. During prolonged radiation delivery, sublethal damage repair takes place, leading to the decreased effect of radiation. In in vivo tumors, however, this decrease in effect may be counterbalanced by rapid reoxygenation. Another issue related to hypofractionated SRT is the mathematical model for dose evaluation and conversion. The linear–quadratic (LQ) model and biologically effective dose (BED) have been suggested to be incorrect when used for hypofractionation. The LQ model overestimates the effect of high fractional doses of radiation. BED is particularly incorrect when used for tumor responses in vivo, since it does not take reoxygenation into account. Correction of the errors, estimated at 5–20%, associated with the use of BED is necessary when it is used for SRT. High fractional doses have been reported to exhibit effects against tumor vasculature and enhance host immunity, leading to increased antitumor effects. This may be an interesting topic that should be further investigated. Radioresistance of hypoxic tumor cells is more problematic in hypofractionated SRT, so trials of hypoxia-targeted agents are encouraged in the future. In this review, the radiobiological characteristics of hypofractionated SRT are summarized, and based on the considerations, we would like to recommend 60 Gy in eight fractions delivered three times a week for lung tumors larger than 2 cm in diameter

  5. Mixed-effects height–diameter models for ten conifers in the inland ...

    African Journals Online (AJOL)

    To demonstrate the utility of mixed-effects height–diameter models when conducting forest inventories, mixedeffects height–diameter models are presented for several commercially and ecologically important conifers in the inland Northwest of the USA. After obtaining height–diameter measurements from a plot/stand of ...

  6. DETEKSI DIAMETER TUMOR PADA KULIT MENGGUNAKAN SEGMENTASI CITRA BERDASARKAN KARAKTERISTIK ABCDE

    Directory of Open Access Journals (Sweden)

    Wuwanjie Septian

    2016-09-01

    ABSTRAK Kanker kulit merupakan pertumbuhan sel kulit abnormal yang tidak dapat dikendalikan dan pada stadium lanjut dapat mengakibatkan kematian. Menemukan penyakit ini sedini mungkin merupakan salah satu cara untuk menghindari kecacatan maupun kemungkinan terburuk. Karena letaknya dipermukaan kulit, akan mudah bagi siapa saja untuk mengenali sendiri kanker kulit. Deteksi dini kanker kulit dalam bidang dermatologi, dapat dideteksi berdasarkan karakteristik Asymmetrical Shape, Border, Color, Diameter, Evolution (ABCDE. Dalam penelitian ini, deteksi dini difokuskan pada identifikasi diameter pada 30 citra nevus. Metode penelitian berupa pengolahan citra nevus dengan melakukan konversi citra menjadi citra HSI lalu diubah menjadi citra biner, selanjutnya dilakukan tahap segmentasi menggunakan filter median, proses rekonstruksi morfologi dan pada tahap akhir dilakukan deteksi tepi dengan menggunakan operator sobel. Proses deteksi tepi akan mempermudah menghitung nilai luas diameter nevus. Hasil penelitian deteksi dini kanker kulit terhadap 30 citra nevus, diperoleh hasil bahwa metode pengolahan citra yang diusulkan dapat mendeteksi diameter nevus dan berhasil mengidentifikasi citra tersebut sebagai 26 citra memiliki luas diameter nevus yang diidentifikasi sebagai tumor jinak dan 4 citra nevus yang memiliki diameter > 6 mm dan dinyatakan sebagai tumor melanoma. Kata Kunci: Nevus, Melanoma, Segmentasi, Deteksi Diameter

  7. Generalized height-diameter models for Populus tremula L. stands

    African Journals Online (AJOL)

    USER

    2010-07-12

    Jul 12, 2010 ... and stand density) into the base height-diameter models increased the accuracy of prediction for P. tremula. .... parameter estimates compared with those obtained with ... using coefficient of determination for non-linear regression (. 2. R ), ..... stochastic height-diameter model for maritime pine ecoregions in.

  8. Experimental Study on The Two-Phase Flow Characteristics Using Conductivity Probes And Laser Doppler Anemometry In A Vertical Pipe

    Science.gov (United States)

    Chiva, S.; Mendez, S.; Muñoz-Cobo, J. L.; Julia, J. E.; Hernandez, L.

    2007-06-01

    An upward isothermal co-current air-water flow in a vertical pipe (50.2 mm inner diameter) has been experimental investigated. Local measurements of void fraction, interfacial area concentration (IAC), interfacial velocity and Sauter mean diameter were measured using a double sensor conductivity probe. Liquid velocity and turbulence intensity were measured using Laser Doppler Anemometry (LDA). Different air-water flow configurations was investigated for a liquid flow rate ranged from 0.491 m/s to 0.981 m/s and a void fraction up to 10 %. For each two-phase flow configuration twenty five radial position and three axial locations were measured by the conductivity probe methodology, and several radial profiles was measured with LDA at different axial positions.

  9. Search for fractional charge

    International Nuclear Information System (INIS)

    Turner, R.E.

    1984-01-01

    A search was made for fractional charges of the form Z plus two-thirds e, where Z is an integer. It was assumed that the charges exist in natural form bound with other fractional charges in neutral molecules. It was further assumed that these neutral molecules are present in air. Two concentration schemes were employed. One sample was derived from the waste gases from a xenon distillation plant. This assumes that high mass, low vapor pressure components of air are concentrated along with the xenon. The second sample involved ionizing air, allowing a brief recombination period, and then collecting residual ions on the surface of titanium discs. Both samples were analyzed at the University of Rochester in a system using a tandem Van de Graff to accelerate particles through an essentially electrostatic beam handling system. The detector system employed both a Time of Flight and an energy-sensitive gas ionization detector. In the most sensitive mode of analysis, a gas absorber was inserted in the beam path to block the intense background. The presence of an absorber limited the search to highly penetrating particles. Effectively, this limited the search to particles with low Z and masses greater than roughly fifty GeV. The final sensitivities attained were on the order of 1 x 10 -20 for the ionized air sample and 1 x 10 -21 for the gas sample. A discussion of the caveats that could reduce the actual level of sensitivity is included

  10. Can ratio of the biggest tumor diameter to total tumor diameter be a new parameter in the differential diagnosis of agressive and favorable multifocal papillary thyroid microcarcinoma?

    Science.gov (United States)

    Tam, Abbas Ali; Özdemir, Didem; Çuhacı, Neslihan; Başer, Hüsniye; Dirikoç, Ahmet; Aydın, Cevdet; Yazgan, Aylin Kılıç; Ersoy, Reyhan; Çakır, Bekir

    2017-02-01

    In this study, we aimed to evaluate the usefulness of a new parameter -ratio of the biggest tumor diameter to total tumor diameter- for the differentiation of agressive and favorable papillary thyroid microcarcinomas (PTMC). The diameter of the biggest tumor focus was taken as the primary tumor diameter. Total tumor diameter was calculated as the sum of the maximal diameter of each lesion. Ratio of primary tumor diameter to total tumor diameter was defined as tumor diameter ratio (TDR). Positive and negative predictive value, sensitivity and specificity of TDR to predict capsular invasion, extrathyroidal extension (ETE) and lymph node metastasis (LNM) were determined. Mean TDR was significantly lower in multifocal PTMC patients with capsular invasion, ETE, lymphovascular invasion and LNM compared to patients without these features. The sensitivities of TDR for the detection of LNM, ETE and capsular invasion were 100%, 100% and 94.2%, respectively. Specificity of TDR was 86.2% for LNM, 88% for ETE and 94.7% for capsular invasion. Best cut off values of TDR that can predict capsular invasion, ETE and LNM in multifocal PTMC were 0.62, 0.57 and 0.56, respectively. Multifocal papillary thyroid carcinoma patients with capsular invasion, ETE and LNM had significantly lower mean TDR when compared to ones without these features. Decreased TDR was associated with capsular invasion, ETE and LNM in patients with multifocal PTMC and PTC. This new parameter might be particularly helpful for the detection of aggressive behavior in multifocal PTMCs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Altered fractionated radiotherapy has a survival benefit for head and neck cancers. Is it true?

    International Nuclear Information System (INIS)

    Hatano, Kazuo; Sakai, Mitsuhiro; Araki, Hitoshi; Doi, Katsuyuki; Asano, Takanori; Fujikawa, Akira

    2007-01-01

    There was a significant survival benefit with altered fractionated radiotherapy, corresponding to an absolute benefit of 3.4% at 5 years. The benefit was significantly higher with hyperfractionated radiotherapy (8% at 5 years) than with accelerated radiotherapy (2% with accelerated fractionation without total dose reduction and 1.7% with total dose reduction at 5 years). The effect was greater for the primary tumor than for nodal disease. The effect was also more pronounced in younger patients and in those with good performance status. Hyperfractionation seemed to yield a more consistent advantage for survival than accelerated fractionated radiotherapy. However, accelerated radiotherapy might be associated with higher non-cancer related death. We have to evaluate whether the benefit of hyperfractionated radiotherapy versus standard radiotherapy persists when combined with concomitant chemotherapy and the benefit of intensity-modulated radiation therapy (IMRT) compared with altered fractionation. (author)

  12. Feasibility of recanalization of human coronary arteries using high-intensity ultrasound.

    Science.gov (United States)

    Ernst, A; Schenk, E A; Woodlock, T J; Alliger, H; Gottlieb, S; Child, S Z; Meltzer, R S

    1994-01-15

    To investigate the feasibility of ultrasonic recanalization of obstructed human coronary arteries in vitro, high-intensity ultrasound was applied to 16 coronary arteries obtained at autopsy, using a prototype instrument enabling insonification through a catheter tip. It was a 119 cm long, 0.95 mm thick wire in an 8Fr catheter connected to an external ultrasonic transformer and power generator. A 5 MHz phased-array 2-dimensional echocardiography instrument was used to determine minimal luminal diameter and percent diameter narrowing before and after ultrasound application. The ultrasonic energy was delivered at 21.5 kHz and with a 52 +/- 19 micrometer average amplitude of tip displacement. The mean percent luminal diameter narrowing, flow rate and mean pressure gradient before ultrasound exposure were 74 +/- 11%, 97 +/- 61 ml/min, and 92 +/- 18 mm Hg, respectively. After recanalization, the mean percent luminal diameter narrowing decreased to 45 +/- 17% (p ultrasound application. Mechanical fracture of the wire occurred in 8 cases (50%). No signs of thermal injury were found on histology. Thus, ultrasonic recanalization of human coronary arteries in vitro is feasible. It may reduce obstruction and improve blood flow. Debris sizes are sufficiently small to minimize the hazard of peripheral embolization.

  13. Performance of Arrowroot (Marantha arundinacea) in various light intensities

    Science.gov (United States)

    Oktafani, M. B.; Supriyono; Budiastuti, MTh S.; Purnomo, D.

    2018-03-01

    Arrowroot (Marantha arundinacea) is one of the potential food crops to support food security programs. Light intensity is one of the important factors for plant growth. Arrowroot cultivation technology still need further development. Traditionally, arrowroot grows wild under canopy without intentisification of cultivating which have low productivity. The purpose of research was to investigate the suitable light intensity for arrowroot. The experiment was conducted at Jumantono as Experimental Field of Faculty of Agricultural, University of Sebelas Maret Surakarta located in Karanganyar, from March to September 2016. The experiment used a complete randomized block design (CRBD) of light intensity level there are 27400 lux (full sun light), 18900 lux (shaded 31%), 13500 lux (shaded 51%) and 7400 lux (shaded 72%). Each treatment was replicated six times so there were 24 experimental units. The results showed that arrowroot is a low light adaptive plant. Arrowroot under the light intensity 7400 lux (27% full light), the number of leaves and tillers is not significantly different than under full light, although the plant is higher. The highest tuber diameter and length were 1.91 and 25.06 cm, respectively, and tuber weight reached 607.5-651.67 g per plant.

  14. Brain Arterial Diameters as a Risk Factor for Vascular Events

    OpenAIRE

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-01-01

    Background Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Methods and Results Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, ca...

  15. Failure Diameter of PBX 9502: Simulations with the SURFplus model

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-07-03

    SURFplus is a reactive burn model for high explosives aimed at modelling shock initiation and propagation of detonation waves. It utilizes the SURF model for the fast hot-spot reaction plus a slow reaction for the energy released by carbon clustering. A feature of the SURF model is that there is a partially decoupling between burn rate parameters and detonation wave properties. Previously, parameters for PBX 9502 that control shock ini- tiation had been calibrated to Pop plot data (distance-of-run to detonation as a function of shock pressure initiating the detonation). Here burn rate parameters for the high pres- sure regime are adjusted to t the failure diameter and the limiting detonation speed just above the failure diameter. Simulated results are shown for an uncon ned rate stick when the 9502 diameter is slightly above and slightly below the failure diameter. Just above the failure diameter, in the rest frame of the detonation wave, the front is sonic at the PBX/air interface. As a consequence, the lead shock in the neighborhood of the interface is supported by the detonation pressure in the interior of the explosive rather than the reaction immediately behind the front. In the interior, the sonic point occurs near the end of the fast hot-spot reaction. Consequently, the slow carbon clustering reaction can not a ect the failure diameter. Below the failure diameter, the radial extent of the detonation front decreases starting from the PBX/air interface. That is, the failure starts at the PBX boundary and propagates inward to the axis of the rate stick.

  16. Vertebral Artery Diameter and Flow: Nature or Nurture.

    Science.gov (United States)

    Tarnoki, Adam Domonkos; Fejer, Bence; Tarnoki, David Laszlo; Littvay, Levente; Lucatelli, Pierleone; Cirelli, Carlo; Fanelli, Fabrizio; Sacconi, Beatrice; Fagnani, Corrado; Medda, Emanuela; Farina, Filippo; Meneghetti, Giorgio; Horvath, Tamas; Pucci, Giacomo; Schillaci, Giuseppe; Stazi, Maria Antonietta; Baracchini, Claudio

    2017-09-01

    In contrast with the carotid arteries, the vertebral arteries (VAs) show considerable variation in length, caliber, and vessel course. This study investigated whether the variation in diameter and flow characteristics of the VAs might be inherited. A total of 172 Italian twins from Padua, Perugia, and Terni (54 monozygotic, 32 dizygotic) recruited from the Italian Twin Registry underwent B-mode and pulsed-wave Doppler ultrasound assessment of their VAs. VA diameters, peak systolic velocity (PSV) and end diastolic velocity (EDV) were assessed at the level of a horizontal V2 segment. Univariate quantitative genetic modeling was performed. Fourteen percent of the sample had VA hypoplasia. Within pair correlation in monozygotic twins was higher than in dizygotics (.552 vs. .229) for VA diameter. Age- and sex-adjusted genetic effect, under the most parsimonious model, accounted for 54.7% (95% CI: 42.2-69.1%) of the variance of VA diameter, and unshared environmental effect for 45.3% (95% CI: 30.9-57.8%). No heritability was found for the PSV of VA, but shared (34.1%; 95% CI: 16.7-53.7%) and unshared (65.9%; 95% CI: 45.9-83.1%) environmental factors determined the variance. EDV of VA is moderately genetically influenced (42.4%; 95% CI: 16.1-64.9%) and also determined by the unshared environment (57.6%; 95% CI: 34.7-83.7%). The diameter of the VAs is moderately genetically determined. Different factors influence the PSV and EDV of VAs, which may highlight the complex hemodynamic background of VA flow and help to understand the vertebral flow anomalies found by ultrasound. Copyright © 2017 by the American Society of Neuroimaging.

  17. Fractional statistics and fractional quantized Hall effect. Revision

    International Nuclear Information System (INIS)

    Tao, R.; Wu, Y.S.

    1984-01-01

    We suggest that the origin of the odd denominator rule observed in the fractional quantized Hall effect (FQHE) may lie in fractional statistics which governs quasiparticles in FQHE. A theorem concerning statistics of clusters of quasiparticles implies that fractional statistics does not allow coexistence of a large number of quasiparticles at fillings with an even denominator. Thus no Hall plateau can be formed at these fillings, regardless of the presence of an energy gap. 15 references

  18. FRACTIONAL BANKING

    OpenAIRE

    Maria Klimikova

    2010-01-01

    Understanding the reasons of the present financial problems lies In understanding the substance of fractional reserve banking. The substance of fractional banking is in lending more money than the bankers have. Banking of partial reserves is an alternative form which links deposit banking and credit banking. Fractional banking is causing many unfavorable economic impacts in the worldwide system, specifically an inflation.

  19. Combining spray nozzle simulators with meshes: characterization of rainfall intensity and drop properties

    Science.gov (United States)

    Carvalho, Sílvia C. P.; de Lima, João L. M. P.; de Lima, M. Isabel P.

    2013-04-01

    Rainfall simulators can be a powerful tool to increase our understanding of hydrological and geomorphological processes. Nevertheless, rainfall simulators' design and operation might be rather demanding, for achieving specific rainfall intensity distributions and drop characteristics. The pressurized simulators have some advantages over the non-pressurized simulators: drops do not rely on gravity to reach terminal velocity, but are sprayed out under pressure; pressurized simulators also yield a broad range of drop sizes in comparison with drop-formers simulators. The main purpose of this study was to explore in the laboratory the potential of combining spray nozzle simulators with meshes in order to change rainfall characteristics (rainfall intensity and diameters and fall speed of drops). Different types of spray nozzles were tested, such as single full-cone and multiple full-cone nozzles. The impact of the meshes on the simulated rain was studied by testing different materials (i.e. plastic and steel meshes), square apertures and wire thicknesses, and different vertical distances between the nozzle and the meshes underneath. The diameter and fall speed of the rain drops were measured using a Laser Precipitation Monitor (Thies Clima). The rainfall intensity range and coefficients of uniformity of the sprays and the drop size distribution, fall speed and kinetic energy were analysed. Results show that when meshes intercept drop trajectories the spatial distribution of rainfall intensity and the drop size distribution are affected. As the spray nozzles generate typically small drop sizes and narrow drop size distributions, meshes can be used to promote the formation of bigger drops and random their landing positions.

  20. Evolution of the two-phase flow in a vertical tube-decomposition of gas fraction profiles according to bubble size classes using wire-mesh sensors

    Energy Technology Data Exchange (ETDEWEB)

    Prasser, H.M.; Krepper, E.; Lucas, D. [Forschungszentrum Rossendorf e.V., Dresden (Germany)

    2002-01-01

    The wire-mesh sensor developed by the Forschungszentrum Rossendorf produces sequences of instantaneous gas fraction distributions in a cross section with a time resolution of 1200 frames per second and a spatial resolution of about 2-3 mm. At moderate flow velocities (up to 1-2 m.s{sup -1}), bubble size distributions can be obtained, since each individual bubble is mapped in several successive distributions. The method was used to study the evolution of the bubble size distribution in a vertical two-phase flow. For this purpose, the sensor was placed downstream of an air injector, the distance between air injection and sensor was varied. The bubble identification algorithm allows to select bubbles of a given range of the effective diameter and to calculate partial gas fraction profiles for this diameter range. In this way, the different behaviour of small and large bubbles in respect to the action of the lift force was observed in a mixture of small and large bubbles. (authors)

  1. Studies of murine tumor control using x-ray fractionation schedules alone or in combination with hyperthermia

    International Nuclear Information System (INIS)

    Imbra, R.J.

    1981-01-01

    The effectiveness of an experimental radiation fractionation schedule of decreasing-sized dose fractions administered at optimal time intervals was compared with a conventional fractionation schedule of constant-sized dose fractions administered five times per week. Also, the effect of the addition of hyperthermia (42.5 0 C) to radiation therapy was investigated. For some experiments, Ehrlich mammary tumors were growth in the right thighs of Swiss mice. The tumor response was determined by measuring the tumor-bearing leg diameter and converting this value to volume. The time for the treated tumor to regrow to its pre-tratment volume was used as an endpoint in Swiss mice. The maximum total treatment dose is limited by the amount of normal tissue damage. A total treatment dose of six thousand rads was most suitable for the further investigations. Definitive investigations were performed using the RIF-1 tumor grown in the right thigh of C3H mice. The length of mitotic delay of RIF-1 cells, in vivo, was determined after various single doses of x radiation. A direct (exponential) relationship betwen x-ray dose and mitotic delay time was observed. Times of release of the RIF-1 cells from radiation-induced mitotic delay were used to determine the optimum time intervals to deliver the decreasing-sized dose fractions. Six thousand rads administered as decreasing-sized dose fractions resulted in significantly greater RIF-1 tumor control, as compared to conventional radiation therapy. The best treatment schedule, overall, was decreasing-sized dose fractions plus hyperthermia

  2. Characterization of Coconut Oil Fractions Obtained from Solvent Fractionation Using Acetone.

    Science.gov (United States)

    Sonwai, Sopark; Rungprasertphol, Poonyawee; Nantipipat, Nantinee; Tungvongcharoan, Satinee; Laiyangkoon, Nantikan

    2017-09-01

    This work was aimed to study the solvent fraction of coconut oil (CNO). The fatty acid and triacylglycerol compositions, solid fat content (SFC) and the crystallization properties of CNO and its solid and liquid fractions obtained from fractionation at different conditions were investigated using various techniques. CNO was dissolved in acetone (1:1 w/v) and left to crystallize isothermally at 10°C for 0.5, 1 and 2 h and at 12°C for 2, 3 and 6 h. The solid fractions contained significantly lower contents of saturated fatty acids of ≤ 10 carbon atoms but considerably higher contents of saturated fatty acids with > 12 carbon atoms with respect to those of CNO and the liquid fractions. They also contained higher contents of high-melting triacylglycerol species with carbon number ≥ 38. Because of this, the DSC crystallization onset temperatures and the crystallization peak temperatures of the solid fractions were higher than CNO and the liquid fractions. The SFC values of the solid fractions were significantly higher than CNO at all measuring temperatures before reaching 0% just below the body temperature with the fraction obtained at 12°C for 2 h exhibiting the highest SFC. On the contrary, the SFC values of the liquid fractions were lower than CNO. The crystallization duration exhibited strong influence on the solid fractions. There was no effect on the crystal polymorphic structure possibly because CNO has β'-2 as a stable polymorph. The enhanced SFC of the solid fractions would allow them to find use in food applications where a specific melting temperature is desired such as sophisticated confectionery fats, and the decreased SFC of the liquid fractions would provide them with a higher cold stability which would be useful during extended storage time.

  3. Method for varying the diameter of a beam of charged particles

    International Nuclear Information System (INIS)

    Ko, W.C.; Sawatzky, E.

    1977-01-01

    In the bombardment of targets with beams of charged particles, a method is described for varying and controlling the diameter of such beams by passing the beam through an envelope of conductive material. The envelope is spaced from and coaxial with the beam. A selected dc potential is applied to the envelope, and the beam diameter is controlled by changing this applied potential in a direction away from ground potential to increase the beam diameter or by changing the potential in a direction toward ground potential to decrease said beam diameter

  4. Fractional Complex Transform and exp-Function Methods for Fractional Differential Equations

    Directory of Open Access Journals (Sweden)

    Ahmet Bekir

    2013-01-01

    Full Text Available The exp-function method is presented for finding the exact solutions of nonlinear fractional equations. New solutions are constructed in fractional complex transform to convert fractional differential equations into ordinary differential equations. The fractional derivatives are described in Jumarie's modified Riemann-Liouville sense. We apply the exp-function method to both the nonlinear time and space fractional differential equations. As a result, some new exact solutions for them are successfully established.

  5. Fractional factorial plans

    CERN Document Server

    Dey, Aloke

    2009-01-01

    A one-stop reference to fractional factorials and related orthogonal arrays.Presenting one of the most dynamic areas of statistical research, this book offers a systematic, rigorous, and up-to-date treatment of fractional factorial designs and related combinatorial mathematics. Leading statisticians Aloke Dey and Rahul Mukerjee consolidate vast amounts of material from the professional literature--expertly weaving fractional replication, orthogonal arrays, and optimality aspects. They develop the basic theory of fractional factorials using the calculus of factorial arrangements, thereby providing a unified approach to the study of fractional factorial plans. An indispensable guide for statisticians in research and industry as well as for graduate students, Fractional Factorial Plans features: * Construction procedures of symmetric and asymmetric orthogonal arrays. * Many up-to-date research results on nonexistence. * A chapter on optimal fractional factorials not based on orthogonal arrays. * Trend-free plans...

  6. Plasma studies of the permanent magnet electron cyclotron resonance ion source at Peking University.

    Science.gov (United States)

    Ren, H T; Peng, S X; Xu, Y; Zhao, J; Lu, P N; Chen, J; Zhang, A L; Zhang, T; Guo, Z Y; Chen, J E

    2014-02-01

    At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ&SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D(+), 10 mA of O(+), 10 mA of He(+), and 50 mA of H(+)). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.

  7. Plasma studies of the permanent magnet electron cyclotron resonance ion source at Peking University

    Energy Technology Data Exchange (ETDEWEB)

    Ren, H. T.; Peng, S. X., E-mail: sxpeng@pku.edu.cn; Xu, Y.; Zhao, J.; Lu, P. N.; Chen, J.; Zhang, A. L.; Zhang, T.; Guo, Z. Y.; Chen, J. E. [State Key Laboratory of Nuclear Physics and Technology, Institute of Heavy Ion Physics, Peking University, Beijing 100871 (China)

    2014-02-15

    At Peking University (PKU) we have developed several 2.45 GHz Permanent Magnet Electron Cyclotron Resonance ion sources for PKUNIFTY, SFRFQ, Coupled RFQ and SFRFQ, and Dielectric-Wall Accelerator (DWA) projects (respectively, 50 mA of D{sup +}, 10 mA of O{sup +}, 10 mA of He{sup +}, and 50 mA of H{sup +}). In order to improve performance of these ion sources, it is necessary to better understand the principal factors that influence the plasma density and the atomic ion fraction. Theoretical analysis about microwave transmission and cut-off inside the discharge chamber were carried out to study the influence of the discharge chamber diameters. As a consequence, experimental studies on plasma density and ion fraction with different discharge chamber sizes have been carried out. Due to the difficulties in measuring plasma density inside the discharge chamber, the output beam current was measured to reflect the plasma density. Experimental results show that the plasma density increases to the maximum and then decreases significantly as the diameter changed from 64 mm to 30 mm, and the atomic ion fraction has the same tendency. The maximum beam intensity was obtained with the diameter of 35 mm, but the maximum atomic ion fraction with a diameter of 40 mm. The experimental results are basically accordant with the theoretical calculation. Details are presented in this paper.

  8. The Extended Fractional Subequation Method for Nonlinear Fractional Differential Equations

    OpenAIRE

    Zhao, Jianping; Tang, Bo; Kumar, Sunil; Hou, Yanren

    2012-01-01

    An extended fractional subequation method is proposed for solving fractional differential equations by introducing a new general ansätz and Bäcklund transformation of the fractional Riccati equation with known solutions. Being concise and straightforward, this method is applied to the space-time fractional coupled Burgers’ equations and coupled MKdV equations. As a result, many exact solutions are obtained. It is shown that the considered method provides a very effective, convenient, and powe...

  9. Higher fractions theory of fractional hall effect

    International Nuclear Information System (INIS)

    Kostadinov, I.Z.; Popov, V.N.

    1985-07-01

    A theory of fractional quantum Hall effect is generalized to higher fractions. N-particle model interaction is used and the gap is expressed through n-particles wave function. The excitation spectrum in general and the mean field critical behaviour are determined. The Hall conductivity is calculated from first principles. (author)

  10. Unattached fraction and the size distribution of the radon progeny in indoor air

    International Nuclear Information System (INIS)

    Yamasaki, K.; Shimo, M.

    1992-01-01

    The size-distribution of the aerosol-attached radon progeny and the unattached (cluster) fraction were measured by using a low pressure cascade impactor and a single wire screen in a building of the nuclear facility. The radon concentration at the condition of ventilation 'ON' was about 50 Bq m -3 , but it increased exponentially after ventilation 'OFF' and reached to the saturated concentration of about 600 Bq m -3 . At the condition of low aerosol concentration without additional aerosol, the activity median aerodynamic diameter, the geometric standard deviation and the unattached fraction were, respectively, 0.4 μm, 2.7-2.9 and 0.3-0.5. On the other hand, at the condition of high aerosol concentration with burning a mosquito coil, these were, 0.4 μm, 2.1 and 0.02-0.03. These yield 2.5 times higher radiation dose conversion factors at the low aerosol condition than the high aerosol condition. (author)

  11. Relationship Between Endothelial Wall Shear Stress and High-Risk Atherosclerotic Plaque Characteristics for Identification of Coronary Lesions That Cause Ischemia: A Direct Comparison With Fractional Flow Reserve.

    Science.gov (United States)

    Han, Donghee; Starikov, Anna; Ó Hartaigh, Bríain; Gransar, Heidi; Kolli, Kranthi K; Lee, Ji Hyun; Rizvi, Asim; Baskaran, Lohendran; Schulman-Marcus, Joshua; Lin, Fay Y; Min, James K

    2016-12-19

    Wall shear stress (WSS) is an established predictor of coronary atherosclerosis progression. Prior studies have reported that high WSS has been associated with high-risk atherosclerotic plaque characteristics (APCs). WSS and APCs are quantifiable by coronary computed tomography angiography, but the relationship of coronary lesion ischemia-evaluated by fractional flow reserve-to WSS and APCs has not been examined. WSS measures were obtained from 100 evaluable patients who underwent coronary computed tomography angiography and invasive coronary angiography with fractional flow reserve. Patients were categorized according to tertiles of mean WSS values defined as low, intermediate, and high. Coronary ischemia was defined as fractional flow reserve ≤0.80. Stenosis severity was determined by minimal luminal diameter. APCs were defined as positive remodeling, low attenuation plaque, and spotty calcification. The likelihood of having positive remodeling and low-attenuation plaque was greater in the high WSS group compared with the low WSS group after adjusting for minimal luminal diameter (odds ratio for positive remodeling: 2.54, 95% CI 1.12-5.77; odds ratio for low-attenuation plaque: 2.68, 95% CI 1.02-7.06; both Prelationship was observed between WSS and fractional flow reserve when adjusting for either minimal luminal diameter or APCs. WSS displayed no incremental benefit above stenosis severity and APCs for detecting lesions that caused ischemia (area under the curve for stenosis and APCs: 0.87, 95% CI 0.81-0.93; area under the curve for stenosis, APCs, and WSS: 0.88, 95% CI 0.82-0.93; P=0.30 for difference). High WSS is associated with APCs independent of stenosis severity. WSS provided no added value beyond stenosis severity and APCs for detecting lesions with significant ischemia. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  12. High signal intensity lesion in basal ganglia on MR imaging: correlation with portal-systemic encephalopathy in liver cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Ju; Choi, Sun Jeong; Kim, Chang Soo; Kim, Sun Hee; Chung, Chun Phil; Kim, Yang Sook [Maryknoll Hospital, Pusan (Korea, Republic of)

    1993-01-15

    To evaluate of the relationship between basal ganglia lesion and portal-systemic encephalopathy, eleven patients who had clinically proved liver cirrhosis with superior mesenteric vein larger than 10mm in diameter on ultrasonogram underwent brain MR imaging. No evidence of clinical or neuropsychiatric disturbance was observed in any patient at the time of the MR examination. Brain MR imaging revealed basal ganglia lesion characterized by bilateral, symmetric, high signal intensity without edema or mass effect on spin echo T1-weighted images in nine patients which included three patients with the past history of portal-systemic encephalopathy. It was concluded that excepted in the circumstances of other causes of the high signal intensity in basal ganglia on T1-weighted images such as fat, methemoglobin, melanin, neurofibromatosis, dense calcification, and parenteral nutrition, bilateral and symmetric high signal intensity lesion in basal ganglia would be a useful MR finding of subclinical portal-systemic encephalopathy in liver cirrhosis patients with no clinical or neuropsychiatric symptoms and larger than 10mm in diameter of superior mesenteric vein in ultrasonography.

  13. High signal intensity lesion in basal ganglia on MR imaging: correlation with portal-systemic encephalopathy in liver cirrhosis

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Choi, Sun Jeong; Kim, Chang Soo; Kim, Sun Hee; Chung, Chun Phil; Kim, Yang Sook

    1993-01-01

    To evaluate of the relationship between basal ganglia lesion and portal-systemic encephalopathy, eleven patients who had clinically proved liver cirrhosis with superior mesenteric vein larger than 10mm in diameter on ultrasonogram underwent brain MR imaging. No evidence of clinical or neuropsychiatric disturbance was observed in any patient at the time of the MR examination. Brain MR imaging revealed basal ganglia lesion characterized by bilateral, symmetric, high signal intensity without edema or mass effect on spin echo T1-weighted images in nine patients which included three patients with the past history of portal-systemic encephalopathy. It was concluded that excepted in the circumstances of other causes of the high signal intensity in basal ganglia on T1-weighted images such as fat, methemoglobin, melanin, neurofibromatosis, dense calcification, and parenteral nutrition, bilateral and symmetric high signal intensity lesion in basal ganglia would be a useful MR finding of subclinical portal-systemic encephalopathy in liver cirrhosis patients with no clinical or neuropsychiatric symptoms and larger than 10mm in diameter of superior mesenteric vein in ultrasonography

  14. Relationship between the tensile strengths and diameters of human umbilical cords.

    Science.gov (United States)

    Fernando, D M G; Gamage, S M K; Ranmohottige, S; Weerakkody, I; Abeyruwan, H; Parakrama, H

    2018-05-01

    Mothers of alleged infanticides might claim that umbilical cord broke during precipitate delivery causing injuries detected on baby at autopsy. There is paucity of evidence regarding this possibility. The objective of the study was to determine relationship between tensile strength and diameter or weight per unit length of cord. Diameters and weights per unit length of fresh umbilical cords were determined. Tensile strengths were measured by Hounsfield Testing Machine. Relationship between tensile strength versus cord diameter and weight per unit length were analyzed. Of 122 cords, average tensile strength, diameter and weight per centimeter were 50.4 N, 7.73 mm and 6.87 g respectively. The tensile strengths were directly proportional to diameter. There was no association between tensile strength and weight per centimeter. Measurement of the diameter of cord is important during autopsy to predict tensile strength and thereby to presume whether cord could have broken by the weight of the baby. Copyright © 2018 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  15. Diameter Effect of Silver Nanorod Arrays to Surface-enhanced Raman Scattering

    International Nuclear Information System (INIS)

    Gu, Geun Hoi; Kim, Min Young; Yoon, Hyeok Jin; Suh, Jung Sang

    2014-01-01

    The effect the diameter of silver nanorod arrays whose distance between the nanorods was uniform at 65 nm have on Surface-enhanced Raman Scattering (SERS) has been studied by varying the diameter from 28 to 51 nm. Nanorod length was fixed at approximately 62 nm, which is the optimum length for SERS by excitation with a 632.8 nm laser line. The transverse and longitudinal modes of the surface plasmon of these silver nanorods were near 400 and 630 nm, respectively. The extinction of the longitudinal mode increased with increasing nanorod diameter, while the transverse mode did not change significantly. High-quality SERS spectra of p-aminothiophenol and benzenethiol adsorbed on the tips of the silver nanorods were observed by excitation with a 632.8 nm laser line. The SERS enhancement increased with increasing nanorod diameter. We concluded that the SERS enhancement increases when the diameter of silver nanorods is increased mainly by increasing the excitation efficiency of the longitudinal mode. The enhancement factor for the silver nanorods with a 51 nm diameter was approximately 2 Χ 10 7

  16. Diameter-dependent hydrophobicity in carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kyakuno, Haruka, E-mail: h-kyakuno@kanagawa-u.ac.jp [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Institute of Physics, Faculty of Engineering, Kanagawa University, Yokohama 221-8686 (Japan); Fukasawa, Mamoru; Ichimura, Ryota; Nakai, Yusuke; Maniwa, Yutaka, E-mail: maniwa@phys.se.tmu.ac.jp [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); Matsuda, Kazuyuki [Institute of Physics, Faculty of Engineering, Kanagawa University, Yokohama 221-8686 (Japan); Miyata, Yasumitsu [Department of Physics, Graduate School of Science and Engineering, Tokyo Metropolitan University, Hachioji 192-0397 (Japan); PRESTO, JST, Kawaguchi 332-0012 (Japan); Saito, Takeshi [Nanotube Research Center, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8565 (Japan)

    2016-08-14

    Single-wall carbon nanotubes (SWCNTs) are a good model system that provides atomically smooth nanocavities. It has been reported that water-SWCNTs exhibit hydrophobicity depending on the temperature T and the SWCNT diameter D. SWCNTs adsorb water molecules spontaneously in their cylindrical pores around room temperature, whereas they exhibit a hydrophilic-hydrophobic transition or wet-dry transition (WDT) at a critical temperature T{sub wd} ≈ 220-230 K and above a critical diameter D{sub c} ≈ 1.4-1.6 nm. However, details of the WDT phenomenon and its mechanism remain unknown. Here, we report a systematic experimental study involving X-ray diffraction, optical microscopy, and differential scanning calorimetry. It is found that water molecules inside thick SWCNTs (D > D{sub c}) evaporate and condense into ice Ih outside the SWCNTs at T{sub wd} upon cooling, and the ice Ih evaporates and condenses inside the SWCNTs upon heating. On the other hand, residual water trapped inside the SWCNTs below T{sub wd} freezes. Molecular dynamics simulations indicate that upon lowering T, the hydrophobicity of thick SWCNTs increases without any structural transition, while the water inside thin SWCNTs (D < D{sub c}) exhibits a structural transition, forming an ordered ice. This ice has a well-developed hydrogen bonding network adapting to the cylindrical pores of the SWCNTs. Thus, the unusual diameter dependence of the WDT is attributed to the adaptability of the structure of water to the pore dimension and shape.

  17. Initialized Fractional Calculus

    Science.gov (United States)

    Lorenzo, Carl F.; Hartley, Tom T.

    2000-01-01

    This paper demonstrates the need for a nonconstant initialization for the fractional calculus and establishes a basic definition set for the initialized fractional differintegral. This definition set allows the formalization of an initialized fractional calculus. Two basis calculi are considered; the Riemann-Liouville and the Grunwald fractional calculi. Two forms of initialization, terminal and side are developed.

  18. Diameter-tailored telecom-band luminescence in InP/InAs heterostructure nanowires grown on InP (111)B substrate with continuously-modulated diameter from microscale to nanoscale

    Science.gov (United States)

    Zhang, Guoqiang; Tateno, Kouta; Sogawa, Tetsuomi; Gotoh, Hideki

    2018-04-01

    We report diameter-tailored luminescence in telecom band of InP/InAs multi-heterostructure nanowires with continuously-modulated diameter from microscale to nanoscale. By using the self-catalyzed vapor-solid-liquid approach, we tune the indium particle size, and consequently the InP/InAs nanowire diameter, during growth by modulating the flow rate of the indium source material. This technique allows a high degree of continuous tuning in a wide scale from microscale to nanoscale. Hence it offers an original way to bridge the gap between microscale-featured photolithographic and nanoscale-featured nanolithographic processes and to incorporate InAs quantum disks with tunable diameters into a single InP/InAs quantum heterostructure nanowire. We realized site-defined nanowires with nanoscale diameters initiated from site-defined microscale-diameter particles made with a conventional photolithographic process. The luminescence wavelength from InAs quantum disks is directly connected to the nanowire diameter, by which the strain in the InAs quantum disks is tailored. This work provides new opportunities in the fabrication and design of nanowire devices that extends beyond what is achievable with the current technologies and enables the nanowire shape to be engineered thus offering the potential to broaden the application range of nanowire devices.

  19. Measurement error in CT assessment of appendix diameter

    Energy Technology Data Exchange (ETDEWEB)

    Trout, Andrew T.; Towbin, Alexander J. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, MLC 5031, Cincinnati, OH (United States); Zhang, Bin [Cincinnati Children' s Hospital Medical Center, Department of Biostatistics and Epidemiology, Cincinnati, OH (United States)

    2016-12-15

    Appendiceal diameter continues to be cited as an important criterion for diagnosis of appendicitis by computed tomography (CT). To assess sources of error and variability in appendiceal diameter measurements by CT. In this institutional review board-approved review of imaging and medical records, we reviewed CTs performed in children <18 years of age between Jan. 1 and Dec. 31, 2010. Appendiceal diameter was measured in the axial and coronal planes by two reviewers (R1, R2). One year later, 10% of cases were remeasured. For patients who had multiple CTs, serial measurements were made to assess within patient variability. Measurement differences between planes, within and between reviewers, within patients and between CT and pathological measurements were assessed using correlation coefficients and paired t-tests. Six hundred thirty-one CTs performed in 519 patients (mean age: 10.9 ± 4.9 years, 50.8% female) were reviewed. Axial and coronal measurements were strongly correlated (r = 0.92-0.94, P < 0.0001) with coronal plane measurements significantly larger (P < 0.0001). Measurements were strongly correlated between reviewers (r = 0.89-0.9, P < 0.0001) but differed significantly in both planes (axial: +0.2 mm, P=0.003; coronal: +0.1 mm, P=0.007). Repeat measurements were significantly different for one reviewer only in the axial plane (0.3 mm difference, P<0.05). Within patients imaged multiple times, measured appendix diameters differed significantly in the axial plane for both reviewers (R1: 0.5 mm, P = 0.031; R2: 0.7 mm, P = 0.022). Multiple potential sources of measurement error raise concern about the use of rigid diameter cutoffs for the diagnosis of acute appendicitis by CT. (orig.)

  20. Traversal of cells by radiation and absorbed fraction estimates for electrons and alpha particles

    International Nuclear Information System (INIS)

    Eckerman, K.F.; Ryman, J.C.; Taner, A.C.; Kerr, G.D.

    1986-01-01

    Consideration of the pathlength which radiation traverses in a cell is central to algorithms for estimating energy deposition on a cellular level. Distinct pathlength distributions occur for radionuclides: (1) uniformly distributed in space about the cell (referred to as μ-randomness); (2) uniformly distributed on the surface of the cell (S-randomness); and (3) uniformly distributed within the cell volume (I-randomness). For a spherical cell of diameter d, the mean pathlengths are 2/3d, and 3/4d, respectively, for these distributions. Algorithms for simulating the path of radiation through a cell are presented and the absorbed fraction in the cell and its nucleus are tabulated for low energy electrons and alpha particles emitted on the surface of spherical cells. The algorithms and absorbed fraction data should be of interest to those concerned with the dosimetry of radionuclide-labeled monoclonal antibodies. 8 references, 3 figures, 2 tables

  1. Recent development in the evaluation of Moessbauer line intensities

    International Nuclear Information System (INIS)

    Spiering, H.

    1985-01-01

    The angular dependence of the intensities of pure or mixed multipole transitions is formulated in a new fashion, which takes into account arbitrary texture of the Moessbauer absorber ranging from complete orientation (single crystals) over preferred orientation to random powders and an anisotropic absorption fraction of the nuclei. The application of the theory is demonstrated by means of typical examples from the literature. (orig.)

  2. Relationships between diameter and height of trees in natural ...

    African Journals Online (AJOL)

    Relationships between diameter and height of trees in natural tropical forest in Tanzania. Wilson A Mugasha, Ole M Bollandsås, Tron Eid. Abstract. The relationship between tree height (h) and tree diameter at breast height (dbh) is an important element describing forest stands. In addition, h often is a required variable in ...

  3. Fluctuation of void fraction and pressure drop during vertical two-phase flow with contraction

    International Nuclear Information System (INIS)

    Morimoto, Yuichiro; Madarame, Haruki; Okamoto, Koji

    2003-01-01

    Flow pattern and fluctuation of void fraction of two-phase flow through a vertical channel with contraction were examined experimentally. The two-phase fluid consisted of water and nitrogen gas. The pipe diameters were 0.1 [m] and 0.05 [m], which were before and after the contraction, respectively. Superficial gas and liquid velocity were changed form 0.42 to 2.55 [m/s] and from 2.26 to 4.53 [m/s]. Time series data of void fraction were measured using a single-needle void probe and flow pattern at downstream from the contraction was visualized using a high-speed video camera. Intermittent flow was observed at downstream of the contraction. The pulsation can be seen to be caused by wave of bubbles thick and thin. Frequency of fluctuation of the void fraction was almost constant when flow pattern before the contraction was bubble flow. In the case where flow pattern before the contraction was churn flow, the frequency increased with superficial liquid velocity. The frequency was also confirmed with the result of image processing using the movies captured by the high speed video camera. (author)

  4. Bipartite Diametrical Graphs of Diameter 4 and Extreme Orders

    Directory of Open Access Journals (Sweden)

    Salah Al-Addasi

    2008-01-01

    in which this upper bound is attained, this graph can be viewed as a generalization of the Rhombic Dodecahedron. Then we show that for any ≥2, the graph (2,2 is the unique (up to isomorphism bipartite diametrical graph of diameter 4 and partite sets of cardinalities 2 and 2, and hence in particular, for =3, the graph (6,8 which is just the Rhombic Dodecahedron is the unique (up to isomorphism bipartite diametrical graph of such a diameter and cardinalities of partite sets. Thus we complete a characterization of -graphs of diameter 4 and cardinality of the smaller partite set not exceeding 6. We prove that the neighborhoods of vertices of the larger partite set of (2,2 form a matroid whose basis graph is the hypercube . We prove that any -graph of diameter 4 is bipartite self complementary, thus in particular (2,2. Finally, we study some additional properties of (2,2 concerning the order of its automorphism group, girth, domination number, and when being Eulerian.

  5. Real-time precision measuring device of tree diameter growth

    Science.gov (United States)

    Guo, Mingming; Chen, Aijun; Li, Dongsheng; Liu, Nan; Yao, Jingyuan

    2016-01-01

    DBH(diameter at breast height) is an important factor to reflect of the quality of plant growth, also an important parameter indispensable in forest resources inventory and forest carbon sink, the accurate measurement of DBH or not is directly related to the research of forest resources inventory and forest carbon sink. In this paper, the principle and the mathematical model of DBH measurement device were introduced, the fixture measuring device and the hardware circuit for this tree diameter were designed, the measurement software programs were compiled, and the precision measuring device of tree diameter growth was developed. Some experiments with Australia fir were conducted. Based on experiment data, the correlations among the DBH variation of Australian fir, the environment temperature, air humility and PAR(photosynthetically active radiation) were obtained. The effects of environmental parameters (environment temperature, air humility and PAR) on tree diameter were analyzed. Experimental results show that there is a positive correlation between DBH variation of Australian fir and environment temperature, a negative correlation between DBH variation of Australian fir and air humility , so is PAR.

  6. Meadow based Fraction Theory

    OpenAIRE

    Bergstra, Jan A.

    2015-01-01

    In the context of an involutive meadow a precise definition of fractions is formulated and on that basis formal definitions of various classes of fractions are given. The definitions follow the fractions as terms paradigm. That paradigm is compared with two competing paradigms for storytelling on fractions: fractions as values and fractions as pairs.

  7. Variations in eyeball diameters of the healthy adults.

    Science.gov (United States)

    Bekerman, Inessa; Gottlieb, Paul; Vaiman, Michael

    2014-01-01

    The purpose of the current research was to reevaluate the normative data on the eyeball diameters. Methods. In a prospective cohort study, the CT data of consecutive 250 adults with healthy eyes were collected and analyzed, and sagittal, transverse, and axial diameters of both eyeballs were measured. The data obtained from the left eye and from the right eye were compared. The correlation analysis was performed with the following variables: orbit size, gender, age, and ethnic background. Results. We did not find statistically significant differences correlated with gender of the patients and their age. The right eyeball was slightly smaller than the left one but this difference was statistically insignificant (P = 0.17). We did not find statistically significant differences of the eyeball sizes among the ethnicities we dealt with. Strong correlation was found between the transverse diameter and the width of the orbit (r = 0.88). Conclusion. The size of a human adult eye is approximately 24.2 mm (transverse) × 23.7 mm (sagittal) × 22.0-24.8 mm (axial) with no significant difference between sexes and age groups. In the transverse diameter, the eyeball size may vary from 21 mm to 27 mm. These data might be useful in ophthalmological, oculoplastic, and neurological practice.

  8. Investigation of strut-ramp injector in a Scramjet combustor: Effect of strut geometry, fuel and jet diameter on mixing characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Soni, Rahul Kumar; De, Ashoke De [Indian Institute of Technology Kanpur, Kanpur (India)

    2017-03-15

    The strut-based injector has been found to be one of the most promising injector designs for a supersonic combustor, offering enhanced mixing of fuel and air. The mixing and flow field characteristics of the straight (SS) and Tapered strut (TS), with fixed ramp angle and height at free stream Mach number 2 in conjunction with fuel injection at Mach 2.3 have been investigated numerically and reported. In the present investigation, hydrogen (H{sub 2}) and ethylene (C{sub 2}H{sub 4}) are injected in oncoming supersonic flow from the back of the strut, where jet to free stream momentum ratio is maintained at 0.79 and 0.69 for H2 and C{sub 2}H{sub 4}, respectively. The predicted wall static pressure and species mole fractions at various downstream locations are compared with the experimental data for TS case with 0.6 mm jet diameter and found to be in good agreement. Further, the effect of jet diameter and strut geometry on the near field mixing in strut ramp configuration is discussed for both the fuels. The numerical results are assessed based on various parameters for the performance evaluation of different strut ramp configurations. The SS configuration for both the injectant has been found to be an optimum candidate; also it is observed that for higher jet diameter larger combustor length is required to achieve satisfactory near field mixing.

  9. Shiitake mushroom production on small diameter oak logs in Ohio

    Science.gov (United States)

    S.M. Bratkovich

    1991-01-01

    Yields of different strains of shiitake mushrooms (Lentinus edodes) were evaluated when produced on small diameter oak logs in Ohio. Logs averaging between 3-4 inches in diameter were inoculated with four spawn strains in 1985.

  10. Indium mole fraction effect on the structural and optical properties of quaternary AlInGaN epilayers

    International Nuclear Information System (INIS)

    Liu, J P; Jin, R Q; Zhang, J C; Wang, J F; Wu, M; Zhu, J J; Zhao, D G; Wang, Y T; Yang, H

    2004-01-01

    AlInGaN quaternary epilayers with varying In mole fraction were investigated using triple-axis x-ray diffraction and photoluminescence measurements. The indium compositional fluctuation is enhanced with increasing In mole fraction, whereas the mosaicity of the AlInGaN epilayers is determined through the GaN template quality. Based on the analysis of the temperature dependence of the PL peak position, it is found that the localization effect strengthens with increasing In mole fraction due to the larger fluctuations of the In distribution. Increasing the influence of the localized state results in increasing the emission intensity and FWHM with the In content

  11. Degree of polarization and source counts of faint radio sources from Stacking Polarized intensity

    International Nuclear Information System (INIS)

    Stil, J. M.; George, S. J.; Keller, B. W.; Taylor, A. R.

    2014-01-01

    We present stacking polarized intensity as a means to study the polarization of sources that are too faint to be detected individually in surveys of polarized radio sources. Stacking offers not only high sensitivity to the median signal of a class of radio sources, but also avoids a detection threshold in polarized intensity, and therefore an arbitrary exclusion of sources with a low percentage of polarization. Correction for polarization bias is done through a Monte Carlo analysis and tested on a simulated survey. We show that the nonlinear relation between the real polarized signal and the detected signal requires knowledge of the shape of the distribution of fractional polarization, which we constrain using the ratio of the upper quartile to the lower quartile of the distribution of stacked polarized intensities. Stacking polarized intensity for NRAO VLA Sky Survey (NVSS) sources down to the detection limit in Stokes I, we find a gradual increase in median fractional polarization that is consistent with a trend that was noticed before for bright NVSS sources, but is much more gradual than found by previous deep surveys of radio polarization. Consequently, the polarized radio source counts derived from our stacking experiment predict fewer polarized radio sources for future surveys with the Square Kilometre Array and its pathfinders.

  12. Fractional corresponding operator in quantum mechanics and applications: A uniform fractional Schrödinger equation in form and fractional quantization methods

    International Nuclear Information System (INIS)

    Zhang, Xiao; Wei, Chaozhen; Liu, Yingming; Luo, Maokang

    2014-01-01

    In this paper we use Dirac function to construct a fractional operator called fractional corresponding operator, which is the general form of momentum corresponding operator. Then we give a judging theorem for this operator and with this judging theorem we prove that R–L, G–L, Caputo, Riesz fractional derivative operator and fractional derivative operator based on generalized functions, which are the most popular ones, coincide with the fractional corresponding operator. As a typical application, we use the fractional corresponding operator to construct a new fractional quantization scheme and then derive a uniform fractional Schrödinger equation in form. Additionally, we find that the five forms of fractional Schrödinger equation belong to the particular cases. As another main result of this paper, we use fractional corresponding operator to generalize fractional quantization scheme by using Lévy path integral and use it to derive the corresponding general form of fractional Schrödinger equation, which consequently proves that these two quantization schemes are equivalent. Meanwhile, relations between the theory in fractional quantum mechanics and that in classic quantum mechanics are also discussed. As a physical example, we consider a particle in an infinite potential well. We give its wave functions and energy spectrums in two ways and find that both results are the same

  13. Strong diameter-dependence of nanowire emission coupled to waveguide modes

    Energy Technology Data Exchange (ETDEWEB)

    Dam, Dick van, E-mail: a.d.v.dam@tue.nl; Haverkort, Jos E. M. [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Abujetas, Diego R.; Sánchez-Gil, José A. [Instituto de Estructura de la Materia (IEM-CSIC), Consejo Superior de Investigaciones Científicas Serrano, 121, 28006 Madrid (Spain); Bakkers, Erik P. A. M. [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Kavli Institute of Nanoscience, Delft University of Technology, Lorentzweg 1, 2628 CJ Delft (Netherlands); Gómez Rivas, Jaime, E-mail: j.gomezrivas@differ.nl [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands); Dutch Institute for Fundamental Energy Research DIFFER, P.O. Box 6336, 5600 HH Eindhoven (Netherlands)

    2016-03-21

    The emission from nanowires can couple to waveguide modes supported by the nanowire geometry, thus governing the far-field angular pattern. To investigate the geometry-induced coupling of the emission to waveguide modes, we acquire Fourier microscopy images of the photoluminescence of nanowires with diameters ranging from 143 to 208 nm. From the investigated diameter range, we conclude that a few nanometers difference in diameter can abruptly change the coupling of the emission to a specific mode. Moreover, we observe a diameter-dependent width of the Gaussian-shaped angular pattern in the far-field emission. This dependence is understood in terms of interference of the guided modes, which emit at the end facets of the nanowire. Our results are important for the design of quantum emitters, solid state lighting, and photovoltaic devices based on nanowires.

  14. Accuracy in radiosurgery: The influence of collimator diameters and arc weights on the dose distribution for single target

    Energy Technology Data Exchange (ETDEWEB)

    Plazas, M S [National Univ. of Colombia (Colombia); Lefkopoulus, D; Schlienger, M [Service de Radiotherapie, Hopital Tenon, Paris (France). Unite de Radiophysique; Merienne, L [Hopital Sainte Anne, Paris (France). Service de Neurochirurgie

    1996-08-01

    The dosimetric characteristics of mini-beams and dose distributions in beams used for radio surgery defer substantially from beams used in common radiotherapy. The aim of radio surgery is to deliver a high dose to the lesion in one single fraction, while minimizing the dose delivered to the surrounding normal brain tissue. This type of irradiation is performed with a number of continuous arcs located in various corneal (patient sitting) or sagittal (patient in a supine position) inclined planes using a linear accelerator. A treatment planning system should take into account a large number of irradiation parameters such as the collimator diameter, number of arcs, their angular positions, length and weight of the arcs. We analysed the influence of collimator diameters in the range of 6 to 20 mm using 15 MV X-rays and stereo-tactic irradiation of ellipsoidal inclined arterio venous malformations (AVMs) with a single isocenter. Special arc weights were used to obtain an optimized dose distribution with 13 arcs distributed over an angular sector of 120 deg. x 13 deg. In the two studies made we used 3 dimensional dosimetric calculations. The results were used for the treatment of patients and enabled the choice of the optimal irradiation configuration for each patient. (author). 10 refs, 9 figs.

  15. Computing Diameter in the Streaming and Sliding-Window Models (Preprint)

    National Research Council Canada - National Science Library

    Feigenbaum, Joan; Kannan, Sampath; Zhang, Jian

    2002-01-01

    We investigate the diameter problem in the streaming and sliding-window models. We show that, for a stream of n points or a sliding window of size n, any exact algorithm for diameter requires Omega(n) bits of space...

  16. Determination of pore diameter from rejection measurements with a mixture of oligosaccharides

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza-Gomez, Heriberto; Rogel-Hernandez, Eduardo [Universidad Autonoma de Baja California-Tijuana, Facultad de Ciencias Quimicas e Ingenieria, Tijuana, BC (Mexico); Lin, Shui Wai [Centro de Graduados e Investigacion del Instituto Tecnologico de Tijuana, Apdo. Postal 1166, Tijuana, BC (Mexico)

    2005-04-01

    This paper present a method to determine pore diameters and effective transport through membranes using a mixture of oligosaccharides. The results are compared with the Maxwell-Stefan equations. The partition coefficients of the solutes are a function of the pore diameter according to the Ferry equation. Thus, with the pore diameter as the only unknown parameter, rejection is described and the pore diameter is obtained by a Marquardt-Levenberg optimization procedure. (orig.)

  17. Development of gamma-ray densitometer and measurement of void fraction in instantaneous pipe rupture under BWR LOCA condition

    International Nuclear Information System (INIS)

    Yano, Toshikazu

    1983-11-01

    In order to clarify the transient mass flow rate under the instantaneous pipe rupture condition, it is necessary to use a highly sensitive void meter. Therefore, a high-response gamma-ray densitometer was developed for the measurement of void fraction variation caused by flashing vaporization of the high-pressure and -temperature water under the instantaneous pipe rupture accident. The measurement of void fraction was performed in the pipe rupture test under the BWR LOCA condition with a 6-inch diameter pipe. Initial conditions of the water were 6.86 MPa in pressure and the saturation temperature. To prove the reliability and accuracy, a calibration test by falling acrylic void simulators and an air injection test into cold water filled in the pipe were also conducted. The following results are obtained in the pipe rupture test. (1) The cone slit method is very useful to increase the measuring accuracy. (2) It is clearly observed that the apparent increase of void fraction occurs after the rarefaction wave passes. (3) The first maximum of void fraction occurs with some delay time after break. The following minimum void fraction concurs with the maximum pressure in the pressure recovering phenomena and with the maximum blowdown thrust force. (author)

  18. Trawl catch composition during different fishing intensity periods in two Mediterranean demersal fishing grounds

    Directory of Open Access Journals (Sweden)

    Pilar Sánchez

    2007-12-01

    Full Text Available The study was carried out in two fishing grounds on the Mediterranean continental shelf: one in the Adriatic Sea and one in the Catalan Sea. Samplings on board otter trawlers were performed from November 2002 to December 2003 in the Catalan Sea and from February 2003 to January 2004 in the Adriatic Sea. The Adriatic fishing ground was affected by high fishing intensity from January to June, while the Catalan area was highly exploited from September to February. Fishing activity in the Adriatic area was closed for 45 days, and 62 days in the Catalan area; both periods were in summer. Totals of 92 and 88 species were collected in the Adriatic and Catalan fishing grounds respectively. The species composition of the retained and discarded fractions showed close agreement between the two areas. Mullus barbatus showed very low discard rates in both areas, as well as Loligo vulgaris in the Catalan Sea and Merluccius merluccius in the Adriatic Sea. In both fishing grounds Squilla mantis showed high catch rates with low discards, except in March in the Catalan area. In the Adriatic Sea Liocarcinus depurator was characterized by large discard fractions. In both fishing grounds the retained fraction was slightly higher in the high fishing intensity periods than in the low intensity ones (Adriatic Sea: 0.613 vs 0.524; Catalan Sea: 0.597 vs 0.539, even though the Kruskall Wallis test revealed significant differences (p

  19. Atherosclerotic Plaque Characteristics by CT Angiography Identify Coronary Lesions That Cause Ischemia: a Direct Comparison to Fractional Flow Reserve

    Science.gov (United States)

    Park, Hyung-Bok; Heo, Ran; Hartaigh, Bríain ó; Cho, Iksung; Gransar, Heidi; Nakazato, Ryo; Leipsic, Jonathon; Mancini, G.B. John; Koo, Bon-Kwon; Otake, Hiromasa; Budoff, Matthew J.; Berman, Daniel S.; Erglis, Andrejs; Chang, Hyuk-Jae; Min, James K.

    2014-01-01

    Objective We evaluated the association between atherosclerotic plaque characteristics (APCs) by coronary CT angiography (CT) and lesion ischemia by fractional flow reserve (FFR). Background FFR is the gold standard for determining lesion ischemia. While APCs by CT—including aggregate plaque volume % (%APV), positive remodeling (PR), low attenuation plaque (LAP) and spotty calcification (SC)—are associated with future coronary syndromes, their relationship to lesion ischemia is unclear. Methods 252 patients (17 centers, 5 countries) [mean age 63 years, 71% males] underwent CT, with FFR performed for 407 coronary lesions. CT was interpreted for 50% stenosis, with the latter considered obstructive. APCs by CT were defined as: (1) PR, lesion diameter/reference diameter >1.10; (2) LAP, any voxel 50% but not for 50%. PMID:25592691

  20. An antiangiogenic agent (TNP-470) inhibited reoxygenation during fractionated radiotherapy of murine mammary carcinoma

    International Nuclear Information System (INIS)

    Murata, Rumi; Nishimura, Yasumasa; Hiraoka, Masahiro

    1997-01-01

    Purpose: TNP-470, a synthetic analogue of fumagillin which is a natural product of Aspergillus fumigatus, has been noted as an angiogenesis inhibitor. Combined effects of TNP-470 with fractionated radiotherapy (RT) were investigated using a mouse tumor. Methods and Materials: Tumors were early generations of mammary carcinoma in C3H/He mice. Treatments were initiated when tumors reached an average diameter of 4-5 mm. Tumor response was evaluated by tumor growth (TG) time assay and 50% tumor control dose (TCD 50 ) assay. Tumors were irradiated locally under hypoxic conditions or in air. Five fractionated radiation doses were given in the TG time assay, whereas a single dose or 10 fractionated doses were given in the TCD 50 assay. TNP-470 (100 mg/kg) was administered subcutaneously twice a week during and/or after RT. Results: In the TG time assay, significant delay of tumor growth was observed by TNP-470 alone (100 mg/kg x 2) compared with control tumors (p 50 assay, no significant difference in TCD 50 s was observed between RT alone and RT combined with TNP-470 in single dose experiments. Hypoxic fraction of tumors calculated from the TCD 50 s was not affected significantly by administrating TNP-470 24 h before RT. On the other hand, in 10-fraction experiments, the TCD 50 (RT with TNP-470, in air) was significantly higher than the TCD 50 (RT alone, in air) (p 50 (RT with TNP-470) and the TCD 50 (RT alone) under hypoxic conditions

  1. MORPHOMETRIC CHARACTERIZATION OF THE SAND FRACTION IN A SAND GRAIN IMAGE CAPTURE SYSTEM1

    Directory of Open Access Journals (Sweden)

    Lucimar Arruda Viana

    Full Text Available ABSTRACT Morphology studies assume significant importance in analysis of phenomena of granular systems packaging, in particular with a view to the use of the technique of soil stabilization named particle size correction in forest roads. In this context, this study aimed to develop and operationalize a Sand Grain Image Capture System and, hereby, determine the morphological indices of the sand fractions of two sandy soils called João Pinheiro (JP and Cachoeira da Prata (CP. Soil samples, air-dried, were sieved (2.0 mm nominal mesh size for removal of gravels. The materials that passed through the sieve were subjected to dispersion, washing in 0.053 mm nominal mesh size sieve, removal of organic matter and iron oxides to obtain the clean sand fractions. Subsequently, each soil sample was sieved for separation into twelve classes, between the diameters of 0.149 mm and 1.190 mm, using a Rotap shaker. Next, tests were carried out to characterize the morphometric attributes of the twelve classes of sand fractions of the soils studied. For validation of the performance of the Sand Grain Image Capture System, the results were compared to those obtained using a standard procedure for image analysis. The analysis of the results led to the following conclusions: (i the sand fraction of the JP soil presented higher values for the morphometric indices roundness, elongation and compactness compared to sand fraction of the CP soil; and (ii the Sand Grain Image Capture System worked properly, with practicality.

  2. High-intensity pulsed electric field variables affecting Staphylococcus aureus inoculated in milk.

    Science.gov (United States)

    Sobrino-López, A; Raybaudi-Massilia, R; Martín-Belloso, O

    2006-10-01

    Staphylococcus aureus is an important milk-related pathogen that is inactivated by high-intensity pulsed electric fields (HIPEF). In this study, inactivation of Staph. aureus suspended in milk by HIPEF was studied using a response surface methodology, in which electric field intensity, pulse number, pulse width, pulse polarity, and the fat content of milk were the controlled variables. It was found that the fat content of milk did not significantly affect the microbial inactivation of Staph. aureus. A maximum value of 4.5 log reductions was obtained by applying 150 bipolar pulses of 8 mus each at 35 kV/cm. Bipolar pulses were more effective than those applied in the monopolar mode. An increase in electric field intensity, pulse number, or pulse width resulted in a drop in the survival fraction of Staph. aureus. Pulse widths close to 6.7 micros lead to greater microbial death with a minimum number of applied pulses. At a constant treatment time, a greater number of shorter pulses achieved better inactivation than those treatments performed at a lower number of longer pulses. The combined action of pulse number and electric field intensity followed a similar pattern, indicating that the same fraction of microbial death can be reached with different combinations of the variables. The behavior and relationship among the electrical variables suggest that the energy input of HIPEF processing might be optimized without decreasing the microbial death.

  3. Fractional equivalent Lagrangian densities for a fractional higher-order equation

    International Nuclear Information System (INIS)

    Fujioka, J

    2014-01-01

    In this communication we show that the equivalent Lagrangian densities (ELDs) of a fractional higher-order nonlinear Schrödinger equation with stable soliton-like solutions can be related in a hitherto unknown way. This new relationship is described in terms of a new fractional operator that includes both left- and right-sided fractional derivatives. Using this operator it is possible to generate new ELDs that contain different fractional parts, in addition to the already known ELDs, which only differ by a sum of first-order partial derivatives of two arbitrary functions. (fast track communications)

  4. Modeling of radial gas fraction profiles for bubble flow in vertical pipes

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, D.; Krepper, E.; Prasser, H.-M. [Forschungszentrum Rossendorf e.V., Institute of Safety Research, Dresden (Germany)

    2001-07-01

    The paper presents a method for the prediction of radial gas fraction profiles from a given bubble size distribution. The method is based on the assumption of the equilibrium of the forces acting on a bubble perpendicularly to the flow direction. Assuming a large number of bubble size classes radial distributions are calculated separately for all bubble classes. The sum of these distributions is the radial profile of the gas fraction. The results of the model are compared with experimental data for a number of gas and liquid volume flow rates. The experiments were performed at a vertical test loop (inner diameter 50 mm) in FZ-Rossendorf using a wire mesh sensor. The sensor enables the determination of void distributions in the cross section of the loop. A special evaluation procedure supplies bubble size distributions as well as local distributions of bubbles within a predefined interval of bubble sizes. There is a good agreement between experimental and calculated data. In particular the change from wall peaking to core peaking is well predicted. (authors)

  5. Modeling of radial gas fraction profiles for bubble flow in vertical pipes

    International Nuclear Information System (INIS)

    Lucas, D.; Krepper, E.; Prasser, H.-M.

    2001-01-01

    The paper presents a method for the prediction of radial gas fraction profiles from a given bubble size distribution. The method is based on the assumption of the equilibrium of the forces acting on a bubble perpendicularly to the flow direction. Assuming a large number of bubble size classes radial distributions are calculated separately for all bubble classes. The sum of these distributions is the radial profile of the gas fraction. The results of the model are compared with experimental data for a number of gas and liquid volume flow rates. The experiments were performed at a vertical test loop (inner diameter 50 mm) in FZ-Rossendorf using a wire mesh sensor. The sensor enables the determination of void distributions in the cross section of the loop. A special evaluation procedure supplies bubble size distributions as well as local distributions of bubbles within a predefined interval of bubble sizes. There is a good agreement between experimental and calculated data. In particular the change from wall peaking to core peaking is well predicted. (authors)

  6. DISTRIBUTION OF ORGANIC CARBON IN DIFFERENT SOIL FRACTIONS IN ECOSYSTEMS OF CENTRAL AMAZONIA

    Directory of Open Access Journals (Sweden)

    Jean Dalmo de Oliveira Marques

    2015-02-01

    Full Text Available Organic matter plays an important role in many soil properties, and for that reason it is necessary to identify management systems which maintain or increase its concentrations. The aim of the present study was to determine the quality and quantity of organic C in different compartments of the soil fraction in different Amazonian ecosystems. The soil organic matter (FSOM was fractionated and soil C stocks were estimated in primary forest (PF, pasture (P, secondary succession (SS and an agroforestry system (AFS. Samples were collected at the depths 0-5, 5-10, 10-20, 20-40, 40-60, 60-80, 80-100, 100-160, and 160-200 cm. Densimetric and particle size analysis methods were used for FSOM, obtaining the following fractions: FLF (free light fraction, IALF (intra-aggregate light fraction, F-sand (sand fraction, F-clay (clay fraction and F-silt (silt fraction. The 0-5 cm layer contains 60 % of soil C, which is associated with the FLF. The F-clay was responsible for 70 % of C retained in the 0-200 cm depth. There was a 12.7 g kg-1 C gain in the FLF from PF to SS, and a 4.4 g kg-1 C gain from PF to AFS, showing that SS and AFS areas recover soil organic C, constituting feasible C-recovery alternatives for degraded and intensively farmed soils in Amazonia. The greatest total stocks of carbon in soil fractions were, in decreasing order: (101.3 Mg ha-1 of C - AFS > (98.4 Mg ha-1 of C - FP > (92.9 Mg ha-1 of C - SS > (64.0 Mg ha-1 of C - P. The forms of land use in the Amazon influence C distribution in soil fractions, resulting in short- or long-term changes.

  7. Ecological Importance of Large-Diameter Trees in a Temperate Mixed-Conifer Forest

    Science.gov (United States)

    Lutz, James A.; Larson, Andrew J.; Swanson, Mark E.; Freund, James A.

    2012-01-01

    Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. Although both scaling theory and competition theory make predictions about the relative composition and spatial patterns of large-diameter trees compared to smaller diameter trees, these predictions are rarely tested. We established a 25.6 ha permanent plot within which we tagged and mapped all trees ≥1 cm dbh, all snags ≥10 cm dbh, and all shrub patches ≥2 m2. We sampled downed woody debris, litter, and duff with line intercept transects. Aboveground live biomass of the 23 woody species was 507.9 Mg/ha, of which 503.8 Mg/ha was trees (SD = 114.3 Mg/ha) and 4.1 Mg/ha was shrubs. Aboveground live and dead biomass was 652.0 Mg/ha. Large-diameter trees comprised 1.4% of individuals but 49.4% of biomass, with biomass dominated by Abies concolor and Pinus lambertiana (93.0% of tree biomass). The large-diameter component dominated the biomass of snags (59.5%) and contributed significantly to that of woody debris (36.6%). Traditional scaling theory was not a good model for either the relationship between tree radii and tree abundance or tree biomass. Spatial patterning of large-diameter trees of the three most abundant species differed from that of small-diameter conspecifics. For A. concolor and P. lambertiana, as well as all trees pooled, large-diameter and small-diameter trees were spatially segregated through inter-tree distances trees and spatial relationships between large-diameter and small-diameter trees. Long-term observations may reveal regulation of forest biomass and spatial structure by fire, wind, pathogens, and insects in Sierra Nevada mixed-conifer forests. Sustaining ecosystem functions such as carbon storage or provision of specialist species habitat will likely require different management strategies when the functions are performed primarily by a few large trees as opposed to many smaller trees. PMID:22567132

  8. Void fraction measurements in two-phase flow by transmission and scattering of a neutrons beam

    International Nuclear Information System (INIS)

    Souza, M.C.L.

    1984-01-01

    Calibration curves have been obtained which supply average values of void fraction (α) of water-steam two-phase mixtures for bubble, slug, annular and invert annular flow states. The measurements were carried out in simulated models of lucite-air for the steady-state, using the techniques of transmission and diffusion of a thermal neutrons beam. The calibration curves obtained were used for measurements of void fraction in a circuit containing two-phase water-air mixtures, in upward concurrent flow, for slug flow (P sub(max) = 1,06 bar) and annular flow (P sub(max) = 1,33 bar), using the same techniques. In both of the systems, a test section made up of an aluminium (99,9%) tube was used with internal diameter of 25,25 mm and 2,0 mm wall thichness. The beam of neutrons was obtained from a 5 Ci isotopic Am-Be source, thermalised in a cylindrical moderator of paraffin of 500 mm diameter (with H/D=1) which was covered by 2 mm thick cadmium sheets and having in its centre a parallepeliped made from high density polyethilene with the dimensions 240 x 240 x 144 mm. The neutrons escape through a rectangular collimator of 53,0 x 25,25 mm, with a length of 273 mm cut out of a single block of borated paraffin (32% of H 3 BO 3 ). The experimental results are in good agreement with theorical models in published literature. (Author) [pt

  9. Single Fraction Versus Fractionated Linac-Based Stereotactic Radiotherapy for Vestibular Schwannoma: A Single-Institution Experience

    Energy Technology Data Exchange (ETDEWEB)

    Collen, Christine, E-mail: ccollen@uzbrussel.be [Department of Radiation Oncology, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Ampe, Ben [Department of Neurosurgery, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Gevaert, Thierry [Department of Radiation Oncology, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Moens, Maarten [Department of Neurosurgery, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Linthout, Nadine; De Ridder, Mark; Verellen, Dirk [Department of Radiation Oncology, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); D' Haens, Jean [Department of Neurosurgery, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Storme, Guy [Department of Radiation Oncology, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium)

    2011-11-15

    Purpose: To evaluate and compare outcomes for patients with vestibular schwannoma (VS) treated in a single institution with linac-based stereotactic radiosurgery (SRS) or by fractionated stereotactic radiotherapy (SRT). Methods and Materials: One hundred and nineteen patients (SRS = 78, SRT = 41) were treated. For both SRS and SRT, beam shaping is performed by a mini-multileaf collimator. For SRS, a median single dose of 12.5 Gy (range, 11-14 Gy), prescribed to the 80% isodose line encompassing the target, was applied. Of the 42 SRT treatments, 32 treatments consisted of 10 fractions of 3-4 Gy, and 10 patients received 25 sessions of 2 Gy, prescribed to the 100% with the 95% isodose line encompassing the planning target volume. Mean largest tumor diameter was 16.6 mm in the SRS and 24.6 mm in the SRT group. Local tumor control, cranial nerve toxicity, and preservation of useful hearing were recorded. Any new treatment-induced cranial nerve neuropathy was scored as a complication. Results: Median follow-up was 62 months (range, 6-136 months), 5 patients progressed, resulting in an overall 5-year local tumor control of 95%. The overall 5-year facial nerve preservation probability was 88% and facial nerve neuropathy was statistically significantly higher after SRS, after prior surgery, for larger tumors, and in Koos Grade {>=}3. The overall 5-year trigeminal nerve preservation probability was 96%, not significantly influenced by any of the risk factors. The overall 4-year probability of preservation of useful hearing (Gardner-Robertson score 1 or 2) was 68%, not significantly different between SRS or SRT (59% vs. 82%, p = 0.089, log rank). Conclusion: Linac-based RT results in good local control and acceptable clinical outcome in small to medium-sized vestibular schwannomas (VSs). Radiosurgery for large VSs (Koos Grade {>=}3) remains a challenge because of increased facial nerve neuropathy.

  10. THE NEW SOLUTION OF TIME FRACTIONAL WAVE EQUATION WITH CONFORMABLE FRACTIONAL DERIVATIVE DEFINITION

    OpenAIRE

    Çenesiz, Yücel; Kurt, Ali

    2015-01-01

    – In this paper, we used new fractional derivative definition, the conformable fractional derivative, for solving two and three dimensional time fractional wave equation. This definition is simple and very effective in the solution procedures of the fractional differential equations that have complicated solutions with classical fractional derivative definitions like Caputo, Riemann-Liouville and etc. The results show that conformable fractional derivative definition is usable and convenient ...

  11. NEOWISE Reactivation Mission Year Three: Asteroid Diameters and Albedos

    International Nuclear Information System (INIS)

    Masiero, Joseph R.; Mainzer, A. K.; Kramer, E.; Nugent, C.; Cutri, R. M.; Wright, E. L.; Bauer, J. M.; Grav, T.; Sonnett, S.

    2017-01-01

    The Near-Earth Object Wide-field Infrared Survey Explorer (NEOWISE) reactivation mission has completed its third year of surveying the sky in the thermal infrared for near-Earth asteroids and comets. NEOWISE collects simultaneous observations at 3.4 and 4.6  μ m of solar system objects passing through its field of regard. These data allow for the determination of total thermal emission from bodies in the inner solar system, and thus the sizes of these objects. In this paper, we present thermal model fits of asteroid diameters for 170 NEOs and 6110 Main Belt asteroids (MBAs) detected during the third year of the survey, as well as the associated optical geometric albedos. We compare our results with previous thermal model results from NEOWISE for overlapping sample sets, as well as diameters determined through other independent methods, and find that our diameter measurements for NEOs agree to within 26% (1 σ ) of previously measured values. Diameters for the MBAs are within 17% (1 σ ). This brings the total number of unique near-Earth objects characterized by the NEOWISE survey to 541, surpassing the number observed during the fully cryogenic mission in 2010.

  12. NEOWISE Reactivation Mission Year Three: Asteroid Diameters and Albedos

    Energy Technology Data Exchange (ETDEWEB)

    Masiero, Joseph R.; Mainzer, A. K.; Kramer, E. [Jet Propulsion Laboratory/California Institute of Technology, 4800 Oak Grove Drive, MS 183-301, Pasadena, CA 91109 (United States); Nugent, C.; Cutri, R. M. [California Institute of Technology, Infrared Processing and Analysis Center, 1200 California Boulevard, Pasadena, CA 91125 (United States); Wright, E. L. [University of California, Los Angeles, CA 90095 (United States); Bauer, J. M. [University of Maryland, College Park, MD 20742 (United States); Grav, T.; Sonnett, S., E-mail: Joseph.Masiero@jpl.nasa.gov [Planetary Science Institute, 1700 E Fort Lowell Road #106, Tucson, AZ 85719 (United States)

    2017-10-01

    The Near-Earth Object Wide-field Infrared Survey Explorer (NEOWISE) reactivation mission has completed its third year of surveying the sky in the thermal infrared for near-Earth asteroids and comets. NEOWISE collects simultaneous observations at 3.4 and 4.6  μ m of solar system objects passing through its field of regard. These data allow for the determination of total thermal emission from bodies in the inner solar system, and thus the sizes of these objects. In this paper, we present thermal model fits of asteroid diameters for 170 NEOs and 6110 Main Belt asteroids (MBAs) detected during the third year of the survey, as well as the associated optical geometric albedos. We compare our results with previous thermal model results from NEOWISE for overlapping sample sets, as well as diameters determined through other independent methods, and find that our diameter measurements for NEOs agree to within 26% (1 σ ) of previously measured values. Diameters for the MBAs are within 17% (1 σ ). This brings the total number of unique near-Earth objects characterized by the NEOWISE survey to 541, surpassing the number observed during the fully cryogenic mission in 2010.

  13. Short-Term Effects of Low Intensity Thinning on the Fine Root Dynamics of Pinus massoniana Plantations in the Three Gorges Reservoir Area, China

    Directory of Open Access Journals (Sweden)

    Yafei Shen

    2017-11-01

    Full Text Available Fine roots play an important role in plant growth as well as carbon (C and nutrient cycling in terrestrial ecosystems. Fine roots are important for understanding the contribution of forests to the global C cycle. Knowledge about this topic is still limited, especially regarding the effects of different forest management practices. This study investigated the seasonal dynamics of fine roots (<2 mm in masson pine (P. massoniana plantations for one year after low intensity thinning by using a sequential soil coring method. The fine roots showed pronounced seasonal dynamics, with a peak of fine root biomass (FRB occurring in September. Significant differences were noted in the seasonal dynamics of FRB for the different diameter size sub-classes (≤0.5 mm, 0.5–1 mm and 1–2 mm; also FRB was inversely related to soil depth. Moreover, the FRB (≤0.5 mm and 0.5–1 mm except 1–2 mm in the thinning plots was greater than that in the control only in the upper soil layer (0–10 cm. Furthermore, the FRB varied significantly with soil temperature, moisture and nutrients depended on the diameter sub-class considered. Significant differences in the soil temperature and moisture levels were noted between low-intensity thinned and control plots. Soil nutrient levels slightly decreased after low-intensity thinning. In addition, there was a more sensitive relationship between the very fine roots (diameter < 0.5 mm and soil nutrients. Our results showed an influence of low-intensity thinning on the fine root dynamics with a different magnitude according to fine root diameter sub-classes. These results provide a theoretical basis to promote the benefits of C cycling in the management of P. massoniana forests.

  14. The experimental study of bacterial leaching at condition of different ore's diameter

    International Nuclear Information System (INIS)

    Liu Jinhui; Li Lin; Liu Yajie

    2006-01-01

    This papper compared the effect of leaching rate of uranium and the adaptability of bacteria with the condition of different ore's diameter (2-5 mm, 5-10 mm), which use the way of inleakage-leaching. The experiment use the way that firstly acid leaching, and then 2 bacterial leaching. As a reasult that the total leaching-rate of minute diameter ore are always high than the big diameter one. But for the quantum of consumed acid its just a opposition. During bacterial leaching the adaptability of bacteria in big diameter ore are high than in the minute one. So this experiment may offer a bases for a latter industry experiment which use big diameter ore's bacterial leaching. (authors)

  15. Intensity-modulated three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Mohan, Radhe

    1996-01-01

    Optimized intensity-modulated treatments one of the important advances in photon radiotherapy. Intensity modulation provides a greatly increased control over dose distributions. Such control can be maximally exploited to achieve significantly higher levels of conformation to the desired clinical objectives using sophisticated optimization techniques. Safe, rapid and efficient delivery of intensity-modulated treatments has become feasible using a dynamic multi-leaf collimator under computer control. The need for all other field shaping devices such as blocks, wedges and compensators is eliminated. Planning and delivery of intensity-modulated treatments is amenable to automation and development of class solutions for each treatment site and stage which can be implemented not only at major academic centers but on a wide scale. A typical treatment involving as many as 10 fields can be delivered in times shorter than much simpler conventional treatments. The main objective of the course is to give an overview of the current state of the art of planning and delivery methods of intensity-modulated treatments. Specifically, the following topics will be covered using representative optimized plans and treatments: 1. A typical procedure for planning and delivering an intensity-modulated treatment. 2. Quantitative definition of criteria (i.e., the objective function) of optimization of intensity-modulated treatments. Clinical relevance of objectives and the dependence of the quality of optimized intensity-modulated plans upon whether the objectives are stated purely in terms of simple dose or dose-volume criteria or whether they incorporate biological indices. 3. Importance of the lateral transport of radiation in the design of intensity-modulated treatments. Impact on dose homogeneity and the optimum choice of margins. 4. Use of intensity-modulated treatments in escalation of tumor dose for the same or lower normal tissue dose. Fractionation of intensity-modulated treatments

  16. Intensity-modulated three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Mohan, Radhe

    1997-01-01

    Optimized intensity-modulated treatments one of the important advances in photon radiotherapy. Intensity modulation provides a greatly increased control over dose distributions. Such control can be maximally exploited to achieve significantly higher levels of conformation to the desired clinical objectives using sophisticated optimization techniques. Safe, rapid and efficient delivery of intensity-modulated treatments has become feasible using a dynamic multi-leaf collimator under computer control. The need for all other field shaping devices such as blocks, wedges and compensators is eliminated. Planning and delivery of intensity-modulated treatments is amenable to automation and development of class solutions for each treatment site and stage which can be implemented not only at major academic centers but on a wide scale. A typical treatment involving as many as 10 fields can be delivered in times shorter than much simpler conventional treatments. The main objective of the course is to give an overview of the current state of the art of planning and delivery methods of intensity-modulated treatments. Specifically, the following topics will be covered using representative optimized plans and treatments: 1. A typical procedure for planning and delivering an intensity-modulated treatment. 2. Quantitative definition of criteria (i.e., the objective function) of optimization of intensity-modulated treatments. Clinical relevance of objectives and the dependence of the quality of optimized intensity-modulated plans upon whether the objectives are stated purely in terms of simple dose or dose-volume criteria or whether they incorporate biological indices. 3. Importance of the lateral transport of radiation in the design of intensity-modulated treatments. Impact on dose homogeneity and the optimum choice of margins. 4. Use of intensity-modulated treatments in escalation of tumor dose for the same or lower normal tissue dose. Fractionation of intensity-modulated treatments

  17. Long-Term Low Intensity Physical Exercise Attenuates Heart Failure Development in Aging Spontaneously Hypertensive Rats

    Directory of Open Access Journals (Sweden)

    Luana U. Pagan

    2015-04-01

    Full Text Available Background: Physical exercise is a strategy to control hypertension and attenuate pressure overload-induced cardiac remodeling. The influence of exercise on cardiac remodeling during uncontrolled hypertension is not established. We evaluated the effects of a long-term low intensity aerobic exercise protocol on heart failure (HF development and cardiac remodeling in aging spontaneously hypertensive rats (SHR. Methods: Sixteen month old SHR (n=50 and normotensive Wistar-Kyoto (WKY, n=35 rats were divided into sedentary (SED and exercised (EX groups. Rats exercised in treadmill at 12 m/min, 30 min/day, 5 days/week, for four months. The frequency of HF features was evaluated at euthanasia. Statistical analyses: ANOVA and Tukey or Mann-Whitney, and Goodman test. Results: Despite slightly higher systolic blood pressure, SHR-EX had better functional capacity and lower HF frequency than SHR-SED. Echocardiography and tissue Doppler imaging showed no differences between SHR groups. In SHR-EX, however, left ventricular (LV systolic diameter, larger in SHR-SED than WKY-SED, and endocardial fractional shortening, lower in SHR-SED than WKY-SED, had values between those in WKY-EX and SHR-SED not differing from either group. Myocardial function, assessed in LV papillary muscles, showed improvement in SHR-EX over SHR-SED and WKY-EX. LV myocardial collagen fraction and type I and III collagen gene expression were increased in SHR groups. Myocardial hydroxyproline concentration was lower in SHR-EX than SHR-SED. Lysyl oxidase gene expression was higher in SHR-SED than WKY-SED. Conclusion: Exercise improves functional capacity and reduces decompensated HF in aging SHR independent of elevated arterial pressure. Improvement in functional status is combined with attenuation of LV and myocardial dysfunction and fibrosis.

  18. Eustachian tube diameter: Is it associated with chronic otitis media development?

    Science.gov (United States)

    Paltura, Ceki; Can, Tuba Selçuk; Yilmaz, Behice Kaniye; Dinç, Mehmet Emre; Develioğlu, Ömer Necati; Külekçi, Mehmet

    To evaluate the effect of ET diameter on Chronic Otitis Media (COM) pathogenesis. Retrospective. Patients with unilateral COM disease are included in the study. The connection between fibrocartilaginous and osseous segments of the Eustachian Tube (ET) on axial Computed Tomography (CT) images was defined and the diameter of this segment is measured. The measurements were carried out bilaterally and statistically compared. 154 (76 (49%) male, 78 (51%) female patients were diagnosed with unilateral COM and included in the study. The mean diameter of ET was 1947mm (Std. deviation±0.5247) for healthy ears and 1788mm (Std. deviation±0.5306) for diseased ears. The statistical analysis showed a significantly narrow ET diameter in diseased ear side (p<0.01). The dysfunction or anatomical anomalies of ET are correlated with COM. Measuring of the bony diameter of ET during routine Temporal CT examination is recommended for our colleagues. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Magnetorheology of submicron diameter iron microwires dispersed in silicone oil

    International Nuclear Information System (INIS)

    Bell, R C; Karli, J O; Vavreck, A N; Zimmerman, D T; Ngatu, G T; Wereley, N M

    2008-01-01

    We investigate the magnetorheological (MR) properties of suspensions containing iron microwires with 260 nm diameter and two distinct length distributions of 5.4 ± 5.2 µm and 7.6 ± 5.1 µm suspended in silicone oil (0.45 Pa s). The rheological properties of these fluids were determined using a parallel plate rheometer equipped with a variable strength electromagnet. The shear stress was measured as a function of shear rate for increasing applied magnetic fields. These results were modeled using the Bingham-plastic constitutive model to determine the apparent yield stress and viscosity as a function of increasing volume fraction and length of microwires. At a saturated magnetic flux density, the yield stress using the 5.4 µm microwires was found to be 0.65, 2.23, and 4.76 kPa for the 2, 4, and 6 vol% suspensions, respectively. For the 7.6 µm wires, the yield stress increases to 8.2 kPa for the 6 vol% suspension. Compared with conventional MR fluids employing spherical particles, the degree of settling is markedly decreased in the microwire-based fluids. At 6 vol%, conventional fluids display appreciable settling whereas the microwire-based fluids display no discernable settling. Moreover, the rod-shaped microwires are shown to increase the yield stress of the fluids and enhance the MR performance

  20. The Fractions SNARC Revisited: Processing Fractions on a Consistent Mental Number Line.

    Science.gov (United States)

    Toomarian, Elizabeth Y; Hubbard, Edward M

    2017-07-12

    The ability to understand fractions is key to establishing a solid foundation in mathematics, yet children and adults struggle to comprehend them. Previous studies have suggested that these struggles emerge because people fail to process fraction magnitude holistically on the mental number line (MNL), focusing instead on fraction components (Bonato et al. 2007). Subsequent studies have produced evidence for default holistic processing (Meert et al., 2009; 2010), but examined only magnitude processing, not spatial representations. We explored the spatial representations of fractions on the MNL in a series of three experiments: Experiment 1 replicated Bonato et al. (2007); 30 naïve undergraduates compared unit fractions (1/1-1/9) to 1/5, resulting in a reverse SNARC effect. Experiment 2 countered potential strategic biases induced by the limited set of fractions used by Bonato et al. by expanding the stimulus set to include all irreducible, single-digit proper fractions, and asked participants to compare them against 1/2. We observed a classic SNARC effect, completely reversing the pattern from Experiment 1. Together, Experiments 1 and 2 demonstrate that stimulus properties dramatically impact spatial representations of fractions. In Experiment 3, we demonstrated within-subjects reliability of the SNARC effect across both a fractions and whole number comparison task. Our results suggest that adults can indeed process fraction magnitudes holistically, and that their spatial representations occur on a consistent MNL for both whole numbers and fractions.

  1. Normal cardiac diameters in cine-MRI of the heart

    International Nuclear Information System (INIS)

    Hergan, K.; Schuster, A.; Mair, M.; Burger, R.; Toepker, M.

    2004-01-01

    Purpose: To measure the normal diameters of cardiac cavities in standard cardiac views using cine MRI. Materials and Methods: Fifty-six volunteers were examined (27 male, 29 female) on a 1.5 T MR unit with ECG-triggered single shot free precision (SSFP) cine MR sequences and parallel image acquisition. Standardized echocardiographic planes were used to depict the heart of all volunteers (short axis, 4-chamber view, left and right 2-chamber views). The different diameters of the cardiac cavities were measured using a fixed protocol. Results: For the estimation of ventricular dilatation, the important female/male cross diameters of the left ventricle are 45.2±3.4/51.6±4.6 mm diastolic and 30.5±3.5/33.8±3.6 mm systolic, and of the right ventricle 30.7±3.8/37.1±5.9 mm diastolic and 22.3±3.8/28.1±4.4 mm systolic. For the determination of a left ventricular hypertrophy, relevant septal wall thickness measured in the short axis of the left ventricle of female/male volunteers are 8.0±1.0/9.9±1.2 mm diastolic and 10.9±1.4/13.6±1.9 mm systolic. The measured normal values of male volunteers were generally higher than those of female volunteers. The thickness of the ventricular septum correlated well when measured in the short axis and 4-chamber view. When measured in the 4-chamber view, the longitudinal diameter of the ventricles had a higher value in diastole and a lower value in systole, compared to the 2-chamber views of the right and left cardiac cavities. The atrial longitudinal diameters were higher in the 4-chamber view compared to the 2-chamber views, without any difference in systole or diastole. Conclusion: Diameters of cardiac cavities are easily and quickly measured. Using the tables with the normal values published here, it is simple to estimate an abnormal size of the heart. (orig.)

  2. Spatiotemporal closure of fractional laser-ablated channels imaged by optical coherence tomography and reflectance confocal microscopy

    DEFF Research Database (Denmark)

    Banzhaf, Christina A.; Wind, Bas S.; Mogensen, Mette

    2016-01-01

    Background and Objective Optical coherence tomography (OCT) and reflectance confocal microscopy (RCM) offer high-resolution optical imaging of the skin, which may provide benefit in the context of laser-assisted drug delivery. We aimed to characterize postoperative healing of ablative fractional...... laser (AFXL)-induced channels and dynamics in their spatiotemporal closure using in vivo OCT and RCM techniques. Study design/Materials and Methods The inner forearm of healthy subjects (n = 6) was exposed to 10,600 nm fractional CO2 laser using 5 and 25% densities, 120 μm beam diameter, 5, 15, and 25 m......J/microbeam. Treatment sites were scanned with OCT to evaluate closure of AFXL-channels and RCM to evaluate subsequent re-epithelialization. Results OCT and RCM identified laser channels in epidermis and upper dermis as black, ablated tissue defects surrounded by characteristic hyper-and hyporeflective zones. OCT imaged...

  3. Traversal of cells by radiation and absorbed fraction estimates for electrons and alpha particles

    International Nuclear Information System (INIS)

    Eckerman, K.F.; Ryman, J.C.; Taner, A.C.; Kerr, G.D.

    1985-01-01

    Consideration of the pathlength which radiation traverses in a cell is central to algorithms for estimating energy deposition on a cellular level. Distinct pathlength distributions occur for radionuclides: (1) uniformly distributed in space about the cell (referred to as μ-randomness); (2) uniformly distributed on the surface of the cell (S-randomness); and (3) uniformly distributed within the cell volume (I-randomness). For a spherical cell of diameter d, the mean pathlengths are 2/3d, 1/2d, and 3/4d, respectively, for these distributions. Algorithms for simulating the path of radiation through a cell are presented and the absorbed fraction in the cell and its nucleus are tabulated for low energy electrons and alpha particles emitted on the surface of spherical cells. The algorithms and absorbed fraction data should be of interest to those concerned with the dosimetry of radionuclide-labeled monoclonal antibodies. 8 refs., 3 figs., 2 tabs

  4. NEOWISE REACTIVATION MISSION YEAR TWO: ASTEROID DIAMETERS AND ALBEDOS

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, C. R.; Cutri, R. M. [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Mainzer, A.; Bauer, J.; Kramer, E. A.; Masiero, J.; Sonnett, S. [Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109 (United States); Grav, T. [Planetary Science Institute, Tucson, AZ (United States); Wright, E. L., E-mail: cnugent@ipac.caltech.edu [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095 (United States)

    2016-09-01

    The Near-Earth Object Wide-Field Infrared Survey Explorer (NEOWISE) mission continues to detect, track, and characterize minor planets. We present diameters and albedos calculated from observations taken during the second year since the spacecraft was reactivated in late 2013. These include 207 near-Earth asteroids (NEAs) and 8885 other asteroids. Of the NEAs, 84% NEAs did not have previously measured diameters and albedos by the NEOWISE mission. Comparison of sizes and albedos calculated from NEOWISE measurements with those measured by occultations, spacecraft, and radar-derived shapes shows accuracy consistent with previous NEOWISE publications. Diameters and albedos fall within ±∼20% and ±∼40%, 1-sigma, respectively, of those measured by these alternate techniques. NEOWISE continues to preferentially discover near-Earth objects which are large (>100 m), and have low albedos.

  5. EFFECTS OF OXYGEN AND AIR MIXING ON VOID FRACTIONS IN A LARGE SCALE SYSTEM

    International Nuclear Information System (INIS)

    Leishear, R; Hector Guerrero, H; Michael Restivo, M

    2008-01-01

    Oxygen and air mixing with spargers was performed in a 30 foot tall by 30 inch diameter column, to investigate mass transfer as air sparged up through the column and removed saturated oxygen from solution. The mixing techniques required to support this research are the focus of this paper. The fluids tested included water, water with an antifoam agent (AFA), and a high, solids content, Bingham plastic, nuclear waste simulant with AFA, referred to as AZ01 simulant, which is non-radioactive. Mixing of fluids in the column was performed using a recirculation system and an air sparger. The re-circulation system consisted of the column, a re-circulating pump, and associated piping. The air sparger was fabricated from a two inch diameter pipe concentrically installed in the column and open near the bottom of the column. The column contents were slowly re-circulated while fluids were mixed with the air sparger. Samples were rheologically tested to ensure effective mixing, as required. Once the fluids were adequately mixed, oxygen was homogeneously added through the re-circulation loop using a sintered metal oxygen sparger followed by a static mixer. Then the air sparger was re-actuated to remove oxygen from solution as air bubbled up through solution. To monitor mixing effectiveness several variables were monitored, which included flow rates, oxygen concentration, differential pressures along the column height, fluid levels, and void fractions, which are defined as the percent of dissolved gas divided by the total volume of gas and liquid. Research showed that mixing was uniform for water and water with AFA, but mixing for the AZ101 fluid was far more complex. Although mixing of AZ101 was uniform throughout most of the column, gas entrapment and settling of solids significantly affected test results. The detailed test results presented here provide some insight into the complexities of mixing and void fractions for different fluids and how the mixing process itself

  6. EFFECTS OF OXYGEN AND AIR MIXING ON VOID FRACTIONS IN A LARGE SCALE SYSTEM

    Energy Technology Data Exchange (ETDEWEB)

    Leishear, R; Hector Guerrero, H; Michael Restivo, M

    2008-09-11

    Oxygen and air mixing with spargers was performed in a 30 foot tall by 30 inch diameter column, to investigate mass transfer as air sparged up through the column and removed saturated oxygen from solution. The mixing techniques required to support this research are the focus of this paper. The fluids tested included water, water with an antifoam agent (AFA), and a high, solids content, Bingham plastic, nuclear waste simulant with AFA, referred to as AZ01 simulant, which is non-radioactive. Mixing of fluids in the column was performed using a recirculation system and an air sparger. The re-circulation system consisted of the column, a re-circulating pump, and associated piping. The air sparger was fabricated from a two inch diameter pipe concentrically installed in the column and open near the bottom of the column. The column contents were slowly re-circulated while fluids were mixed with the air sparger. Samples were rheologically tested to ensure effective mixing, as required. Once the fluids were adequately mixed, oxygen was homogeneously added through the re-circulation loop using a sintered metal oxygen sparger followed by a static mixer. Then the air sparger was re-actuated to remove oxygen from solution as air bubbled up through solution. To monitor mixing effectiveness several variables were monitored, which included flow rates, oxygen concentration, differential pressures along the column height, fluid levels, and void fractions, which are defined as the percent of dissolved gas divided by the total volume of gas and liquid. Research showed that mixing was uniform for water and water with AFA, but mixing for the AZ101 fluid was far more complex. Although mixing of AZ101 was uniform throughout most of the column, gas entrapment and settling of solids significantly affected test results. The detailed test results presented here provide some insight into the complexities of mixing and void fractions for different fluids and how the mixing process itself

  7. A dosimetric comparison of two-phase adaptive intensity-modulated radiotherapy for locally advanced nasopharyngeal cancer

    OpenAIRE

    Chitapanarux, Imjai; Chomprasert, Kittisak; Nobnaop, Wannapa; Wanwilairat, Somsak; Tharavichitkul, Ekasit; Jakrabhandu, Somvilai; Onchan, Wimrak; Traisathit, Patrinee; Van Gestel, Dirk

    2015-01-01

    The purpose of this investigation was to evaluate the potential dosimetric benefits of a two-phase adaptive intensity-modulated radiotherapy (IMRT) protocol for patients with locally advanced nasopharyngeal cancer (NPC). A total of 17 patients with locally advanced NPC treated with IMRT had a second computed tomography (CT) scan after 17 fractions in order to apply and continue the treatment with an adapted plan after 20 fractions. To simulate the situation without adaptation, a hybrid plan w...

  8. Twentieth-century decline of large-diameter trees in Yosemite National Park, California, USA

    Science.gov (United States)

    Lutz, J.A.; van Wagtendonk, J.W.; Franklin, J.F.

    2009-01-01

    Studies of forest change in western North America often focus on increased densities of small-diameter trees rather than on changes in the large tree component. Large trees generally have lower rates of mortality than small trees and are more resilient to climate change, but these assumptions have rarely been examined in long-term studies. We combined data from 655 historical (1932-1936) and 210 modern (1988-1999) vegetation plots to examine changes in density of large-diameter trees in Yosemite National Park (3027 km2). We tested the assumption of stability for large-diameter trees, as both individual species and communities of large-diameter trees. Between the 1930s and 1990s, large-diameter tree density in Yosemite declined 24%. Although the decrease was apparent in all forest types, declines were greatest in subalpine and upper montane forests (57.0% of park area), and least in lower montane forests (15.3% of park area). Large-diameter tree densities of 11 species declined while only 3 species increased. Four general patterns emerged: (1) Pinus albicaulis, Quercus chrysolepis, and Quercus kelloggii had increases in density of large-diameter trees occur throughout their ranges; (2) Pinus jeffreyi, Pinus lambertiana, and Pinus ponderosa, had disproportionately larger decreases in large-diameter tree densities in lower-elevation portions of their ranges; (3) Abies concolor and Pinus contorta, had approximately uniform decreases in large-diameter trees throughout their elevational ranges; and (4) Abies magnifica, Calocedrus decurrens, Juniperus occidentalis, Pinus monticola, Pseudotsuga menziesii, and Tsuga mertensiana displayed little or no change in large-diameter tree densities. In Pinus ponderosa-Calocedrus decurrens forests, modern large-diameter tree densities were equivalent whether or not plots had burned since 1936. However, in unburned plots, the large-diameter trees were predominantly A. concolor, C. decurrens, and Q. chrysolepis, whereas P. ponderosa

  9. Reply to "Comment on 'Fractional quantum mechanics' and 'Fractional Schrödinger equation' ".

    Science.gov (United States)

    Laskin, Nick

    2016-06-01

    The fractional uncertainty relation is a mathematical formulation of Heisenberg's uncertainty principle in the framework of fractional quantum mechanics. Two mistaken statements presented in the Comment have been revealed. The origin of each mistaken statement has been clarified and corrected statements have been made. A map between standard quantum mechanics and fractional quantum mechanics has been presented to emphasize the features of fractional quantum mechanics and to avoid misinterpretations of the fractional uncertainty relation. It has been shown that the fractional probability current equation is correct in the area of its applicability. Further studies have to be done to find meaningful quantum physics problems with involvement of the fractional probability current density vector and the extra term emerging in the framework of fractional quantum mechanics.

  10. Mesophilic anaerobic co-digestion of the organic fraction of municipal solid waste with the liquid fraction from hydrothermal carbonization of sewage sludge.

    Science.gov (United States)

    De la Rubia, M A; Villamil, J A; Rodriguez, J J; Borja, R; Mohedano, A F

    2018-06-01

    In the present study, the influence of substrate pre-treatment (grinding and sieving) on batch anaerobic digestion of the organic fraction of municipal solid waste (OFMSW) was first assessed, then followed by co-digestion experiments with the liquid fraction from hydrothermal carbonization (LFHTC) of dewatered sewage sludge (DSS). The methane yield of batch anaerobic digestion after grinding and sieving (20 mm diameter) the OFMSW was considerably higher (453 mL CH 4 STP g -1 VS added ) than that of untreated OFMSW (285 mL CH 4 STP g -1 VS added ). The modified Gompertz model adequately predicted process performance. The maximum methane production rate, R m , for ground and sieved OFMSW was 2.4 times higher than that of untreated OFMSW. The anaerobic co-digestion of different mixtures of OFMSW and LFHTC of DSS did not increase the methane yield above that of the anaerobic digestion of OFMSW alone, and no synergistic effects were observed. However, the co-digestion of both wastes at a ratio of 75% OFMSW-25% LFHTC provides a practical waste management option. The experimental results were adequately fitted to a first-order kinetic model showing a kinetic constant virtually independent of the percentage of LFHTC (0.52-0.56 d -1 ) and decreasing slightly for 100% LFHTC (0.44 d -1 ). Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Fractionated radiosurgery for painful spinal metastases: DOSIS - a phase II trial

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Hawkins, Maria; Flentje, Michael; Sweeney, Reinhart A

    2012-01-01

    One third of all cancer patients will develop bone metastases and the vertebral column is involved in approximately 70% of these patients. Conventional radiotherapy with of 1–10 fractions and total doses of 8-30 Gy is the current standard for painful vertebral metastases; however, the median pain response is short with 3–6 months and local tumor control is limited with these rather low irradiation doses. Recent advances in radiotherapy technology – intensity modulated radiotherapy for generation of highly conformal dose distributions and image-guidance for precise treatment delivery – have made dose-escalated radiosurgery of spinal metastases possible and early results of pain and local tumor control are promising. The current study will investigate efficacy and safety of radiosurgery for painful vertebral metastases and three characteristics will distinguish this study. 1) A prognostic score for overall survival will be used for selection of patients with longer life expectancy to allow for analysis of long-term efficacy and safety. 2) Fractionated radiosurgery will be performed with the number of treatment fractions adjusted to either good (10 fractions) or intermediate (5 fractions) life expectancy. Fractionation will allow inclusion of tumors immediately abutting the spinal cord due to higher biological effective doses at the tumor - spinal cord interface compared to single fraction treatment. 3) Dose intensification will be performed in the involved parts of the vertebrae only, while uninvolved parts are treated with conventional doses using the simultaneous integrated boost concept. It is the study hypothesis that hypo-fractionated image-guided radiosurgery significantly improves pain relief compared to historic data of conventionally fractionated radiotherapy. Primary endpoint is pain response 3 months after radiosurgery, which is defined as pain reduction of ≥ 2 points at the treated vertebral site on the 0 to 10 Visual Analogue Scale. 60 patients

  12. Corrosion and deposit determination in large diameter pipes by radiography

    International Nuclear Information System (INIS)

    Harara, W.

    2006-08-01

    Two steel reference pipes with outer diameters of 8 and 12 inches were machined to make artificial defects on each of them, such as inside and outside steps of different wall thicknesses, inside and outside flat bottomed holes (FBH) of different diameters and depths on steps, flat area (FA), and ground patch (GP). The artificial defect were made to simulate natural corrosion attack as regular corrosion and pitting. The two reference pipes were tested according to tangential radiography technique and double wall single image technique. Tangential radiography technique had been applied using Co-60 radio-isotope to determine the steps thicknesses, the FBH, the remaining wall thickness under the FA, the remaining wall thickness above the GP, and the minimum detectable thickness of the artificial cement deposit on the two reference pipes, with and without insulation. Double wall single image technique had also been applied on the two reference pipes with and without insulation using Ir-192 radio-isotope to measure the flat bottomed holes depths, GP depth, and FA depth by density measurement. The measurement results obtained from the radiographs confirm that, tangential radiography technique can be applied to detect and evaluate the inside and outside regular corrosion attack in the large diameter pipes. It can also be applied to detect and evaluate the outside FBH with depth equal or greater than 10%. Inside 10% FBH and inside 20% FBH can not be detected if their diameters are not larger than certain value related to diameter and wall thickness of the pipe under test. Increasing the film density up to 5 outside the pipe did not provide any detection improvement of 10% and 20% inside FBH. Tangential radiography technique can also be applied to detect and measure the deposit inside the pipes. Double wall technique can be applied as an alternative method of the tangential radiography technique to detect and to evaluate the shallow and small diameter, 10% and 20% inside FBH

  13. Formation of anorthosite on the Moon through magma ocean fractional crystallization

    Directory of Open Access Journals (Sweden)

    Tatsuyuki Arai

    2017-03-01

    Full Text Available Lunar anorthosite is a major rock of the lunar highlands, which formed as a result of plagioclase-floatation in the lunar magma ocean (LMO. Constraints on the sufficient conditions that resulted in the formation of a thick pure anorthosite (mode of plagioclase >95 vol.% is a key to reveal the early magmatic evolution of the terrestrial planets. To form the pure lunar anorthosite, plagioclase should have separated from the magma ocean with low crystal fraction. Crystal networks of plagioclase and mafic minerals develop when the crystal fraction in the magma (φ is higher than ca. 40–60 vol.%, which inhibit the formation of pure anorthosite. In contrast, when φ is small, the magma ocean is highly turbulent, and plagioclase is likely to become entrained in the turbulent magma rather than separated from the melt. To determine the necessary conditions in which anorthosite forms from the LMO, this study adopted the energy criterion formulated by Solomatov. The composition of melt, temperature, and pressure when plagioclase crystallizes are constrained by using MELTS/pMELTS to calculate the density and viscosity of the melt. When plagioclase starts to crystallize, the Mg# of melt becomes 0.59 at 1291 °C. The density of the melt is smaller than that of plagioclase for P > 2.1 kbar (ca. 50 km deep, and the critical diameter of plagioclase to separate from the melt becomes larger than the typical crystal diameter of plagioclase (1.8–3 cm. This suggests that plagioclase is likely entrained in the LMO just after the plagioclase starts to crystallize. When the Mg# of melt becomes 0.54 at 1263 °C, the density of melt becomes larger than that of plagioclase even for 0 kbar. When the Mg# of melt decreases down to 0.46 at 1218 °C, the critical diameter of plagioclase to separate from the melt becomes 1.5–2.5 cm, which is nearly equal to the typical plagioclase of the lunar anorthosite. This suggests that plagioclase could separate from the

  14. Comprehensive database of diameter-based biomass regressions for North American tree species

    Science.gov (United States)

    Jennifer C. Jenkins; David C. Chojnacky; Linda S. Heath; Richard A. Birdsey

    2004-01-01

    A database consisting of 2,640 equations compiled from the literature for predicting the biomass of trees and tree components from diameter measurements of species found in North America. Bibliographic information, geographic locations, diameter limits, diameter and biomass units, equation forms, statistical errors, and coefficients are provided for each equation,...

  15. Size measurement of radioactive aerosol particles in intense radiation fields using wire screens and imaging plates

    Energy Technology Data Exchange (ETDEWEB)

    Oki, Yuichi; Tanaka, Toru; Takamiya, Koichi; Ishi, Yoshihiro; UesugI, Tomonori; Kuriyama, Yasutoshi; Sakamoto, Masaaki; Ohtsuki, Tsutomu [Kyoto University Research Reactor Institute, Osaka (Japan); Nitta, Shinnosuke [Graduate School of Engineering, Kyoto University, Kyoto (Japan); Osada, Naoyuki [Advanced Science Research Center, Okayama University, Okayama (Japan)

    2016-09-15

    Very fine radiation-induced aerosol particles are produced in intense radiation fields, such as high-intensity accelerator rooms and containment vessels such as those in the Fukushima Daiichi nuclear power plant (FDNPP). Size measurement of the aerosol particles is very important for understanding the behavior of radioactive aerosols released in the FDNPP accident and radiation safety in high-energy accelerators. A combined technique using wire screens and imaging plates was developed for size measurement of fine radioactive aerosol particles smaller than 100 nm in diameter. This technique was applied to the radiation field of a proton accelerator room, in which radioactive atoms produced in air during machine operation are incorporated into radiation-induced aerosol particles. The size of 11C-bearing aerosol particles was analyzed using the wire screen technique in distinction from other positron emitters in combination with a radioactive decay analysis. The size distribution for 11C-bearing aerosol particles was found to be ca. 70 μm in geometric mean diameter. The size was similar to that for 7Be-bearing particles obtained by a Ge detector measurement, and was slightly larger than the number-based size distribution measured with a scanning mobility particle sizer. The particle size measuring method using wire screens and imaging plates was successfully applied to the fine aerosol particles produced in an intense radiation field of a proton accelerator. This technique is applicable to size measurement of radioactive aerosol particles produced in the intense radiation fields of radiation facilities.

  16. US Intergroup Anal Carcinoma Trial: Tumor Diameter Predicts for Colostomy

    Science.gov (United States)

    Ajani, Jaffer A.; Winter, Kathryn A.; Gunderson, Leonard L.; Pedersen, John; Benson, Al B.; Thomas, Charles R.; Mayer, Robert J.; Haddock, Michael G.; Rich, Tyvin A.; Willett, Christopher G.

    2009-01-01

    Purpose The US Gastrointestinal Intergroup Radiation Therapy Oncology Group 98-11 anal carcinoma trial showed that cisplatin-based concurrent chemoradiotherapy resulted in a significantly higher rate of colostomy compared with mitomycin-based therapy. Established prognostic variables for patients with anal carcinoma include tumor diameter, clinical nodal status, and sex, but pretreatment variables that would predict the likelihood of colostomy are unknown. Methods A secondary analysis was performed by combining patients in the two treatment arms to evaluate whether new predictive and prognostic variables would emerge. Univariate and multivariate analyses were carried out to correlate overall survival (OS), disease-free survival, and time to colostomy (TTC) with pretreatment and treatment variables. Results Of 682 patients enrolled, 644 patients were assessable and analyzed. In the multivariate analysis, tumor-related prognosticators for poorer OS included node-positive cancer (P ≤ .0001), large (> 5 cm) tumor diameter (P = .01), and male sex (P = .016). In the treatment-related categories, cisplatin-based therapy was statistically significantly associated with a higher rate of colostomy (P = .03) than was mitomycin-based therapy. In the pretreatment variables category, only large tumor diameter independently predicted for TTC (P = .008). Similarly, the cumulative 5-year colostomy rate was statistically significantly higher for large tumor diameter than for small tumor diameter (Gray's test; P = .0074). Clinical nodal status and sex were not predictive of TTC. Conclusion The combined analysis of the two arms of RTOG 98-11, representing the largest prospective database, reveals that tumor diameter (irrespective of the nodal status) is the only independent pretreatment variable that predicts TTC and 5-year colostomy rate in patients with anal carcinoma. PMID:19139424

  17. Generalized fractional Schroedinger equation with space-time fractional derivatives

    International Nuclear Information System (INIS)

    Wang Shaowei; Xu Mingyu

    2007-01-01

    In this paper the generalized fractional Schroedinger equation with space and time fractional derivatives is constructed. The equation is solved for free particle and for a square potential well by the method of integral transforms, Fourier transform and Laplace transform, and the solution can be expressed in terms of Mittag-Leffler function. The Green function for free particle is also presented in this paper. Finally, we discuss the relationship between the cases of the generalized fractional Schroedinger equation and the ones in standard quantum

  18. Basic maneuvers for an inspection robot for small diameter gas distribution mains

    NARCIS (Netherlands)

    Dertien, Edwin Christian; Stramigioli, Stefano

    2011-01-01

    This video shows the design of a mechanical structure of a miniature pipe inspection robot (MPR) capable of moving trough very small pipes (up to 41 mm inner diameter) as well as a wide range of diameters (63 to 125 mm outer diameter). The requirement to negotiate bends, T-joints and steep

  19. Effects of Specimen Diameters on the Distribution of Corrosion Fatigue Cracks

    OpenAIRE

    石原, 外美; 塩澤, 和章; 宮尾, 嘉寿

    1988-01-01

    The distribution of corrosion fatigue cracks observed on the un-notched round specimen surface differs with specimen diameter, especially in the low stress amplitude region. At a constant fatigue life ratio, many long cracks are initiated on the larger specimen, 12 mm (diameter), in comparison with the smaller specimen, 6 mm (diameter). On the other hand, in the high stress amplitude region of corrosion fatigue and fatigue in laboratory air, the distribution of cracks during the fatigue proce...

  20. A basic characteristic of signal intensity in MRI

    International Nuclear Information System (INIS)

    Doi, Tsukasa

    2009-01-01

    For evaluation of the significance of signal intensity and contrast which determine the MR imaging quality, SNR (signal-to-noise ratio) and CNR (contrast-to-noise ratio) were studied as their respective measures on the cross-talk artifact (CTA), partial volume effect (PVE), intensity of the fast spin echo (SE) imaging and contrast in the 3T field area (Con). The machine used was 3.0T Signa HDx (GE). CTA, the SNR-reducing coherence between neighboring slices at multi-slice imaging, was studied with a series of phantoms of 0.75-4 mm diameter acrylic pins in cupric sulfate solution with various imaging modes and slice numbers to calculate CNR and contrast (C) involving SNR factor. PVE, the determinant of the intensity depending on the mixture of different tissues within a voxel (slice thickness), was studied with similar phantoms to above with 1-12 mm thick slices and different slice gaps to obtain CNR and C. The intensity of fast SE image was studied with phantoms in a brain-equivalent 0.125 mM Gd solution of sealed water, 0.25-0.5mM Gd, butter, salad oil and detergent on magnetization transfer, J-coupling and diffusion. Con in the 3T machine was studied with the same phantoms as above on the image contrasts at the central and peripheral imaging areas and the intensity/contrast changes by different coils. Presented data of above examinations revealed the effects of characteristic of each environmental factor, and of which recognition was concluded necessary to exactly read the obtained images. (K.T.)

  1. Multi-keV X-ray area source intensity at SGII laser facility

    Science.gov (United States)

    Wang, Rui-rong; An, Hong-hai; Xie, Zhi-yong; Wang, Wei

    2018-05-01

    Experiments for investigating the feasibility of multi-keV backlighters for several different metallic foil targets were performed at the Shenguang II (SGII) laser facility in China. Emission spectra in the energy range of 1.65-7.0 keV were measured with an elliptically bent crystal spectrometer, and the X-ray source size was measured with a pinhole camera. The X-ray intensity near 4.75 keV and the X-ray source size for titanium targets at different laser intensity irradiances were studied. By adjusting the total laser energy at a fixed focal spot size, laser intensity in the range of 1.5-5.0 × 1015 W/cm2, was achieved. The results show that the line emission intensity near 4.75 keV and the X-ray source size are dependent on the laser intensity and increase as the laser intensity increases. However, an observed "peak" in the X-ray intensity near 4.75 keV occurs at an irradiance of 4.0 × 1015 W/cm2. For the employed experimental conditions, it was confirmed that the laser intensity could play a significant role in the development of an efficient multi-keV X-ray source. The experimental results for titanium indicate that the production of a large (˜350 μm in diameter) intense backlighter source of multi-keV X-rays is feasible at the SGII facility.

  2. Geometrical explanation of the fractional complex transform and derivative chain rule for fractional calculus

    International Nuclear Information System (INIS)

    He, Ji-Huan; Elagan, S.K.; Li, Z.B.

    2012-01-01

    The fractional complex transform is suggested to convert a fractional differential equation with Jumarie's modification of Riemann–Liouville derivative into its classical differential partner. Understanding the fractional complex transform and the chain rule for fractional calculus are elucidated geometrically. -- Highlights: ► The chain rule for fractional calculus is invalid, a counter example is given. ► The fractional complex transform is explained geometrically. ► Fractional equations can be converted into differential equations.

  3. A feasibility study: Selection of a personalized radiotherapy fractionation schedule using spatiotemporal optimization

    International Nuclear Information System (INIS)

    Kim, Minsun; Stewart, Robert D.; Phillips, Mark H.

    2015-01-01

    Purpose: To investigate the impact of using spatiotemporal optimization, i.e., intensity-modulated spatial optimization followed by fractionation schedule optimization, to select the patient-specific fractionation schedule that maximizes the tumor biologically equivalent dose (BED) under dose constraints for multiple organs-at-risk (OARs). Methods: Spatiotemporal optimization was applied to a variety of lung tumors in a phantom geometry using a range of tumor sizes and locations. The optimal fractionation schedule for a patient using the linear-quadratic cell survival model depends on the tumor and OAR sensitivity to fraction size (α/β), the effective tumor doubling time (T d ), and the size and location of tumor target relative to one or more OARs (dose distribution). The authors used a spatiotemporal optimization method to identify the optimal number of fractions N that maximizes the 3D tumor BED distribution for 16 lung phantom cases. The selection of the optimal fractionation schedule used equivalent (30-fraction) OAR constraints for the heart (D mean ≤ 45 Gy), lungs (D mean ≤ 20 Gy), cord (D max ≤ 45 Gy), esophagus (D max ≤ 63 Gy), and unspecified tissues (D 05 ≤ 60 Gy). To assess plan quality, the authors compared the minimum, mean, maximum, and D 95 of tumor BED, as well as the equivalent uniform dose (EUD) for optimized plans to conventional intensity-modulated radiation therapy plans prescribing 60 Gy in 30 fractions. A sensitivity analysis was performed to assess the effects of T d (3–100 days), tumor lag-time (T k = 0–10 days), and the size of tumors on optimal fractionation schedule. Results: Using an α/β ratio of 10 Gy, the average values of tumor max, min, mean BED, and D 95 were up to 19%, 21%, 20%, and 19% larger than those from conventional prescription, depending on T d and T k used. Tumor EUD was up to 17% larger than the conventional prescription. For fast proliferating tumors with T d less than 10 days, there was no

  4. Nuclear criticality safety calculational analysis for small-diameter containers

    International Nuclear Information System (INIS)

    LeTellier, M.S.; Smallwood, D.J.; Henkel, J.A.

    1995-11-01

    This report documents calculations performed to establish a technical basis for the nuclear criticality safety of favorable geometry containers, sometimes referred to as 5-inch containers, in use at the Portsmouth Gaseous Diffusion Plant. A list of containers currently used in the plant is shown in Table 1.0-1. These containers are currently used throughout the plant with no mass limits. The use of containers with geometries or material types other than those addressed in this evaluation must be bounded by this analysis or have an additional analysis performed. The following five basic container geometries were modeled and bound all container geometries in Table 1.0-1: (1) 4.32-inch-diameter by 50-inch-high polyethylene bottle; (2) 5.0-inch-diameter by 24-inch-high polyethylene bottle; (3) 5.25-inch-diameter by 24-inch-high steel can (open-quotes F-canclose quotes); (4) 5.25-inch-diameter by 15-inch-high steel can (open-quotes Z-canclose quotes); and (5) 5.0-inch-diameter by 9-inch-high polybottle (open-quotes CO-4close quotes). Each container type is evaluated using five basic reflection and interaction models that include single containers and multiple containers in normal and in credible abnormal conditions. The uranium materials evaluated are UO 2 F 2 +H 2 O and UF 4 +oil materials at 100% and 10% enrichments and U 3 O 8 , and H 2 O at 100% enrichment. The design basis safe criticality limit for the Portsmouth facility is k eff + 2σ < 0.95. The KENO study results may be used as the basis for evaluating general use of these containers in the plant

  5. High-resolution computed tomography evaluation of the bronchial lumen to vertebral body diameter and pulmonary artery to vertebral body diameter ratios in anesthetized ventilated normal cats.

    Science.gov (United States)

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron

    2017-10-01

    Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.

  6. Self-regulating and diameter-selective growth of GaN nanowires

    International Nuclear Information System (INIS)

    Kuo, C-K; Hsu, C-W; Wu, C-T; Lan, Z-H; Mou, C-Y; Chen, C-C; Yang, Y-J; Chen, L-C; Chen, K-H

    2006-01-01

    We report diameter-selective growth of GaN nanowires (NWs) by using mono-dispersed Au nanoparticles (NPs) on a ligand-modified Si substrate. The thiol-terminal silane was found to be effective in producing well-dispersed Au NPs in low density on Si substrates so that the agglomeration of Au NPs during growth could be avoided. The resultant GaN NWs exhibited a narrow diameter distribution and their mean diameter was always larger than, while keeping a deterministic relation with, the size of the Au NPs from which they were grown. A self-regulating steady growth model is proposed to account for the size-control process

  7. Silica fractionation and reactivity in soils

    Science.gov (United States)

    Unzué Belmonte, Dácil; Barão, Lúcia; Vandevenne, Floor; Schoelynck, Jonas; Struyf, Eric; Meire, Patrick

    2014-05-01

    The Si cycle is a globally important biogeochemical cycle, with strong connections to other biogeochemical cycles, including C. Silica is taken up by plants to form protective structures called phytoliths, which become a part of the soil and contribute strongly to soil Si cycling upon litter burial. Different silica fractions are found in soils, with phytoliths among the most easily soluble, especially compared to silicate minerals. A whole set of secondary non-biogenic fractions exist, that also have a high reactivity (adsorbed Si, reactive secondary minerals…). A good characterization of the different fractions of reactive silica is crucial to move forward knowledge on ecosystem Si cycling, which has been recognized in the last decade as crucial for terrestrial Si fluxes. A new method to analyze the different fractions of silica in soils has been described by Koning et al. (2002) and adapted by our research team (Barão et al. 2013). Using a continuous extraction of Si and aluminum in 0.5M NaOH, biogenic and non-biogenic reactive fractions are separated based on their Si/Al ratios and their reactivity in NaOH. Applying this new method I will investigate three emerging ideas on how humans can affect directly terrestrial Si fluxes. -Land use. I expect strong silica fractionation and reactivity differences in different land uses. These effects due to agricultural and forestry management have already been shown earlier in temperate soils (Vandevenne et al. 2012). Now we will test this hypothesis in recently deforested soils, in the south of Brazil. 'Pristine' forest, managed forest and tobacco field soils (with and without rotation crops) will be studied. This research belongs to an interdisciplinary project on soils and global change. -Fire. According to the IPCC report, extreme events such as fires (number and intensity) would increase due to climate change. We analyzed litter from spruce forest, beech forest and peat soils at two burning levels, after 350°C and

  8. Fractional order differentiation by integration: An application to fractional linear systems

    KAUST Repository

    Liu, Dayan

    2013-02-04

    In this article, we propose a robust method to compute the output of a fractional linear system defined through a linear fractional differential equation (FDE) with time-varying coefficients, where the input can be noisy. We firstly introduce an estimator of the fractional derivative of an unknown signal, which is defined by an integral formula obtained by calculating the fractional derivative of a truncated Jacobi polynomial series expansion. We then approximate the FDE by applying to each fractional derivative this formal algebraic integral estimator. Consequently, the fractional derivatives of the solution are applied on the used Jacobi polynomials and then we need to identify the unknown coefficients of the truncated series expansion of the solution. Modulating functions method is used to estimate these coefficients by solving a linear system issued from the approximated FDE and some initial conditions. A numerical result is given to confirm the reliability of the proposed method. © 2013 IFAC.

  9. Antioxidant activity of cod (Gadus morhua) protein hydrolysates: Fractionation and characterisation of peptide fractions

    DEFF Research Database (Denmark)

    Farvin Habebullah, Sabeena; Andersen, Lisa Lystbæk; Otte, Jeanette

    2016-01-01

    This study aimed to characterise peptide fractions (>5 kDa, 3–5 kDa and fractions were dominated by Ala, Gly, Glu and Ser. The total amino acid composition had high proportions of Lys, Ala...... and Glu. The 3–5 kDa and fractions were further fractionated by size exclusion chromatography. All sub-fractions showed high Fe2+ chelating activity. The DPPH radical-scavenging activity of the 3–5 kDa fraction was exerted mainly by one sub-fraction dominated by peptides with masses below 600 Da....... The DPPH radical-scavenging activity of the fraction was exerted by sub-fractions with low molecular weight. The highest reducing power was found in a sub-fraction containing peptides rich in Arg, Tyr and Phe. Both free amino acids and low molecular weight peptides thus seemed to contribute...

  10. Dividing Fractions: A Pedagogical Technique

    Science.gov (United States)

    Lewis, Robert

    2016-01-01

    When dividing one fraction by a second fraction, invert, that is, flip the second fraction, then multiply it by the first fraction. To multiply fractions, simply multiply across the denominators, and multiply across the numerators to get the resultant fraction. So by inverting the division of fractions it is turned into an easy multiplication of…

  11. Retrobulbar diameter of optic nerve in glaucoma

    Directory of Open Access Journals (Sweden)

    Stefanović Ivan

    2009-01-01

    Full Text Available Introduction. The ultrasound diagnostics of the optic nerve includes the analysis of the optic nerve disc (PNO and measuring of its retrobulbar diameter. With B-scan, by Schraeder's method, it is possible to measure very precisely the optic nerve, the pial diameter, the normal values for the pial diameter being 2.8-4.1 mm. In glaucoma, the disease that is most frequently associated with higher intraocular pressure, there comes the destruction of nerve fibres, which can be visualized as the excavation of the optic nerve disc. Objective. In this paper, we were interested in finding whether in glaucoma, and in what phase of the disease, the optic nerve starts growing thinner. Aware of many forms of this very complex disease, we were interested in knowing if the visualization of excavation on the optic nerve disc is related to diminishing of the pial diameter of the retrobulbar nerve part. Methods. There were treated the patients who had already had the diagnosis of glaucoma and the visualized excavation of the optic disc of various dimensions. Echographically, there was measured the thickness of the retrobulbar part of the optic nerve and the finding compared in relation to the excavation of the optic disc. Results. In all eyes with glaucoma, a normal size of the retrobulbar part of the optic nerve was measured, ranging from 3.01 to 3.91 mm with the median of 3.36 mm. Also, by testing the correlation between the thickness of the optic nerve and the excavation of the PNO, by Pearson test, we found that there was no correlation between these two parameters (r=0.109; p>0.05. Conclusion. In the patients with glaucoma, the retrobulbar part of the optic nerve is not thinner (it has normal values, even not in the cases with a totally excavated optic disc. There is no connection between the size of the PNO excavation and the thickness of the retrobulbar part of the optic nerve.

  12. Micro-fractional ablative skin resurfacing with two novel erbium laser systems.

    Science.gov (United States)

    Dierickx, Christine C; Khatri, Khalil A; Tannous, Zeina S; Childs, James J; Cohen, Richard H; Erofeev, Andrei; Tabatadze, David; Yaroslavsky, Ilya V; Altshuler, Gregory B

    2008-02-01

    Fractional ablation offers the potential benefits of full-surface ablative skin resurfacing while minimizing adverse effects. The purpose of this study was to evaluate the safety, damage profile, and efficacy of erbium fractional lasers. Histology from animal and human skin as well as clinical evaluations were conducted with erbium YAG (2,940 nm) and erbium YSGG (2,790 nm) fractional lasers varying pulse width, microbeam (microb) energy, number of passes, and stacking of pulses. Single-pulse treatment parameters from 1 to 12 mJ per 50-70 microm diameter microbeam and 0.25-5 milliseconds pulse widths produced microcolumns of ablation with border coagulation of up to 100 microm width and 450 microm depth. Stacking of pulses generated deeper microcolumns. Clinical observations and in vivo histology demonstrate rapid re-epithelization and limited adverse side effects. Facial treatments were performed in the periorbital and perioral areas using 1-8 passes of single and stacked pulses. Treatments were well-tolerated and subjects could resume their normal routine in 4 days. A statistically significant reduction in wrinkle scores at 3 months was observed for both periorbital and perioral wrinkles using blinded grading. For periorbital treatments of four passes or more, over 90% had > or =1 score wrinkle reduction (0-9 scale) and 42% had > or =2. For perioral wrinkles, over 50% had substantial improvements (> or =2). The clinical observations and histology findings demonstrate that micro-fractional ablative treatment with 2,790 and 2,940 nm erbium lasers resulted in safe and effective wrinkle reduction with minimal patient downtime. The depth and width of the ablated microcolumns and varying extent of surrounding coagulation can be controlled and used to design new treatment procedures targeted for specific indications and areas such as moderate to severe rhytides and photodamaged skin.

  13. Thermogravimetric characteristics of typical municipal solid waste fractions during co-pyrolysis.

    Science.gov (United States)

    Zhou, Hui; Long, YanQiu; Meng, AiHong; Li, QingHai; Zhang, YanGuo

    2015-04-01

    The interactions of nine typical municipal solid waste (MSW) fractions during pyrolysis were investigated using the thermogravimetric analyzer (TGA). To compare the mixture results with the calculation results of superposition of single fractions quantitatively, TG overlap ratio was introduced. There were strong interactions between orange peel and rice (overlap ratio 0.9736), and rice and poplar wood (overlap ratio 0.9774). The interactions of mixture experiments postponed the peak and lowered the peak value. Intense interactions between PVC and rice, poplar wood, tissue paper, wool, terylene, and rubber powder during co-pyrolysis were observed, and the pyrolysis at low temperature was usually promoted. The residue yield was increased when PVC was blended with rice, poplar wood, tissue paper, or rubber powder; while the residue yield was decreased when PVC was blended with wool. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Measurements of stem diameter: implications for individual- and stand-level errors.

    Science.gov (United States)

    Paul, Keryn I; Larmour, John S; Roxburgh, Stephen H; England, Jacqueline R; Davies, Micah J; Luck, Hamish D

    2017-08-01

    Stem diameter is one of the most common measurements made to assess the growth of woody vegetation, and the commercial and environmental benefits that it provides (e.g. wood or biomass products, carbon sequestration, landscape remediation). Yet inconsistency in its measurement is a continuing source of error in estimates of stand-scale measures such as basal area, biomass, and volume. Here we assessed errors in stem diameter measurement through repeated measurements of individual trees and shrubs of varying size and form (i.e. single- and multi-stemmed) across a range of contrasting stands, from complex mixed-species plantings to commercial single-species plantations. We compared a standard diameter tape with a Stepped Diameter Gauge (SDG) for time efficiency and measurement error. Measurement errors in diameter were slightly (but significantly) influenced by size and form of the tree or shrub, and stem height at which the measurement was made. Compared to standard tape measurement, the mean systematic error with SDG measurement was only -0.17 cm, but varied between -0.10 and -0.52 cm. Similarly, random error was relatively large, with standard deviations (and percentage coefficients of variation) averaging only 0.36 cm (and 3.8%), but varying between 0.14 and 0.61 cm (and 1.9 and 7.1%). However, at the stand scale, sampling errors (i.e. how well individual trees or shrubs selected for measurement of diameter represented the true stand population in terms of the average and distribution of diameter) generally had at least a tenfold greater influence on random errors in basal area estimates than errors in diameter measurements. This supports the use of diameter measurement tools that have high efficiency, such as the SDG. Use of the SDG almost halved the time required for measurements compared to the diameter tape. Based on these findings, recommendations include the following: (i) use of a tape to maximise accuracy when developing allometric models, or when

  15. Fractional charges

    International Nuclear Information System (INIS)

    Saminadayar, L.

    2001-01-01

    20 years ago fractional charges were imagined to explain values of conductivity in some materials. Recent experiments have proved the existence of charges whose value is the third of the electron charge. This article presents the experimental facts that have led theorists to predict the existence of fractional charges from the motion of quasi-particles in a linear chain of poly-acetylene to the quantum Hall effect. According to the latest theories, fractional charges are neither bosons nor fermions but anyons, they are submitted to an exclusive principle that is less stringent than that for fermions. (A.C.)

  16. Fractional laser microablation of skin aimed at enhancing its permeability for nanoparticles

    International Nuclear Information System (INIS)

    Genina, Elina A; Dolotov, L E; Bashkatov, A N; Terentyuk, G S; Maslyakova, G N; Zubkina, E A; Tuchin, Valerii V; Yaroslavsky, I V; Altshuler, G B

    2011-01-01

    A new method for delivering nanoparticles into the skin using the fractional laser microablation of its surface and the ultrasonic treatment is proposed. As a result of in vitro and in vivo studies, it is shown that the 290-nm laser pulses with the energy from 0.5 to 3.0 J provide the penetration of nanoparticles of titanium dioxide with the diameter ∼100 nm from the skin surface to the depth, varying from 150 to 400 μm. Histological testing of the skin areas, subjected to the treatment, shows that the particles stay in the dermis at the depth up to 400 μm no less than for three weeks. (optical technologies in biophysics and medicine)

  17. Investigation of the ramp testing behaviour of fuel pins with different diameters

    International Nuclear Information System (INIS)

    Pott, G.; Herren, M.; Wigger, B.

    1979-09-01

    The aim of these experiments was the investigation of the influence of different fuel pin diameter on the ramp testing behaviour. Fuel elements with diameter between 10,75 and 15,6 mm and different cladding thickness had been ramptested in the HBWR (Halden Boiling Water Reactor) after preirradiated in the same facility. Fuel pins with the smallest diameter of 10,75 mm failed. This was indicated by fission gas release measurement. Metallographic examination showed these failure were caused by hydride blisters. A systematic influence of fuel pin diameter and cladding thickness on the ramptesting behaviour was not observed. (orig.) [de

  18. Inner Retinal Oxygen Extraction Fraction in Response to Light Flicker Stimulation in Humans

    Science.gov (United States)

    Felder, Anthony E.; Wanek, Justin; Blair, Norman P.; Shahidi, Mahnaz

    2015-01-01

    Purpose Light flicker has been shown to stimulate retinal neural activity, increase blood flow, and alter inner retinal oxygen metabolism (MO2) and delivery (DO2). The purpose of the study was to determine the change in MO2 relative to DO2 due to light flicker stimulation in humans, as assessed by the inner retinal oxygen extraction fraction (OEF). Methods An optical imaging system, based on a modified slit lamp biomicroscope, was developed for simultaneous measurements of retinal vascular diameter (D) and oxygen saturation (SO2). Retinal images were acquired in 20 healthy subjects before and during light flicker stimulation. Arterial and venous D (DA and DV) and SO2 (SO2A and SO2V) were quantified within a circumpapillary region. Oxygen extraction fraction was defined as the ratio of MO2 to DO2 and was calculated as (SO2A − SO2V)/SO2A. Reproducibility of measurements was assessed. Results Coefficients of variation and intraclass correlation coefficients of repeated measurements were <5% and ≥0.83, respectively. During light flicker stimulation, DA, DV , and SO2V significantly increased (P ≤ 0.004). Oxygen extraction fraction was 0.37 ± 0.08 before light flicker and significantly decreased to 0.31 ± 0.07 during light flicker (P = 0.001). Conclusions Oxygen extraction fraction before and during light flicker stimulation is reported in human subjects for the first time. Oxygen extraction fraction decreased during light flicker stimulation, indicating the change in DO2 exceeded that of MO2. This technology is potentially useful for the detection of changes in OEF response to light flicker in physiological and pathological retinal conditions. PMID:26469748

  19. Image Structure-Preserving Denoising Based on Difference Curvature Driven Fractional Nonlinear Diffusion

    Directory of Open Access Journals (Sweden)

    Xuehui Yin

    2015-01-01

    Full Text Available The traditional integer-order partial differential equations and gradient regularization based image denoising techniques often suffer from staircase effect, speckle artifacts, and the loss of image contrast and texture details. To address these issues, in this paper, a difference curvature driven fractional anisotropic diffusion for image noise removal is presented, which uses two new techniques, fractional calculus and difference curvature, to describe the intensity variations in images. The fractional-order derivatives information of an image can deal well with the textures of the image and achieve a good tradeoff between eliminating speckle artifacts and restraining staircase effect. The difference curvature constructed by the second order derivatives along the direction of gradient of an image and perpendicular to the gradient can effectively distinguish between ramps and edges. Fourier transform technique is also proposed to compute the fractional-order derivative. Experimental results demonstrate that the proposed denoising model can avoid speckle artifacts and staircase effect and preserve important features such as curvy edges, straight edges, ramps, corners, and textures. They are obviously superior to those of traditional integral based methods. The experimental results also reveal that our proposed model yields a good visual effect and better values of MSSIM and PSNR.

  20. On the fractional systems fault detection: a comparison between fractional and rational residual sensitivity

    International Nuclear Information System (INIS)

    Aoun, M.; Aribi, A.; Najar, S.; Abdelkrim, M.N.

    2011-01-01

    This paper shows the interest of extending the dynamic parity space fault detection method for fractional systems. Accordingly, a comparison between fractional and rational residual generators using the later method is presented. An analysis of fractional and rational residuals sensitivity shows the merits of the fractional residual generators. A numerical example illustrating the advantage of using fractional residual generators for fractional systems diagnosis is given.

  1. Determination of the Tapping Part Diameter of the Thread Mill

    Directory of Open Access Journals (Sweden)

    A. E. Dreval'

    2015-01-01

    Full Text Available Currently, there is a tendency to increase the proportion of thread milling operations, among other ways of tapping, which is associated with increasing number of CNC machines, flexibility and versatility of the process.Developments presently existing in the RF and used in the thread mills deal, mainly, with the thread milling cutter designs, to process internal and external thread with straight flutes made from high-speed steel.The paper presents a technique to calculate and select the initial design parameters, i.e. the external diameter of the tapping part of thread milling cutter, which is chosen as a basic computational design. The analysis of directories of tool companies containing foreign de-signs of solid thread end-milling cutters has shown that most of them rep-resent the thread cutter designs made of solid carbide. There are solid and interlocking side milling cutters, which use a tapping part both as a single-disk and as a multi-disk one; chip flutes are made to be both as direct and as screw; solid designs of cutters are made from carbide with a diameter of up to 20 ... 25 mm; thread cutters can be left- and right-hand cutting; Designs of the combined thread mills are proposed; internal channels are used for coolant supply.It is shown that the purpose of the external diameter of the tapping part of the thread mill should take into account the effect of the thread mill diameter on the milling process performance, precision of thread profile received, taper thread, tool strength, and the volume of flutes.The analysis has shown that when choosing the external diameter of the thread mill it worth taking its maximum diameter to improve the char-acteristics of the process under the restrictions imposed on the accuracy of the formed thread.

  2. The evaluation of the right inferior phrenic artery diameter in cirrhotic patients.

    Science.gov (United States)

    Esen, Kaan; Balci, Yuksel; Tok, Sermin; Ucbilek, Enver; Kara, Engin; Kaya, Omer

    2017-09-01

    The purpose of this study is to evaluate the relationship between right inferior phrenic artery diameter and portal hypertension in cirrhotic patients. CT examinations of 38 patients with chronic liver disease (patient group) and 40 patients without any liver disease (control group) were evaluated. The right inferior phrenic artery diameter of the patient and control group were measured. CT findings of portal hypertension, which were accepted as ascites, collaterals, splenomegaly and portal vein diameter greater than 13 mm, were determined and scored in the patient group. Patients obtained scores between one and four with respect to portal hypertension findings, and the scores were compared with phrenic artery diameters. Child-Pugh and MELD scores of the patients were also calculated. The mean diameter of the right inferior phrenic artery in the patient group was larger than that in the control group (p phrenic artery diameter of the patients with score 1 was significantly different from those with score 2 (p = 0.028), score 3 (p = 0.001) and score 4 (p = 0.005). We found a linear and moderate relationship between phrenic artery diameter values and Child-Pugh scores (p = 0.012, r = 0.405). Dilatation of the right inferior phrenic artery in cirrhotic patients may be a nonspecific sign of developing portal hypertension.

  3. Exact solutions to the time-fractional differential equations via local fractional derivatives

    Science.gov (United States)

    Guner, Ozkan; Bekir, Ahmet

    2018-01-01

    This article utilizes the local fractional derivative and the exp-function method to construct the exact solutions of nonlinear time-fractional differential equations (FDEs). For illustrating the validity of the method, it is applied to the time-fractional Camassa-Holm equation and the time-fractional-generalized fifth-order KdV equation. Moreover, the exact solutions are obtained for the equations which are formed by different parameter values related to the time-fractional-generalized fifth-order KdV equation. This method is an reliable and efficient mathematical tool for solving FDEs and it can be applied to other non-linear FDEs.

  4. Fractional-order adaptive fault estimation for a class of nonlinear fractional-order systems

    KAUST Repository

    N'Doye, Ibrahima; Laleg-Kirati, Taous-Meriem

    2015-01-01

    This paper studies the problem of fractional-order adaptive fault estimation for a class of fractional-order Lipschitz nonlinear systems using fractional-order adaptive fault observer. Sufficient conditions for the asymptotical convergence of the fractional-order state estimation error, the conventional integer-order and the fractional-order faults estimation error are derived in terms of linear matrix inequalities (LMIs) formulation by introducing a continuous frequency distributed equivalent model and using an indirect Lyapunov approach where the fractional-order α belongs to 0 < α < 1. A numerical example is given to demonstrate the validity of the proposed approach.

  5. Fractional-order adaptive fault estimation for a class of nonlinear fractional-order systems

    KAUST Repository

    N'Doye, Ibrahima

    2015-07-01

    This paper studies the problem of fractional-order adaptive fault estimation for a class of fractional-order Lipschitz nonlinear systems using fractional-order adaptive fault observer. Sufficient conditions for the asymptotical convergence of the fractional-order state estimation error, the conventional integer-order and the fractional-order faults estimation error are derived in terms of linear matrix inequalities (LMIs) formulation by introducing a continuous frequency distributed equivalent model and using an indirect Lyapunov approach where the fractional-order α belongs to 0 < α < 1. A numerical example is given to demonstrate the validity of the proposed approach.

  6. An advanced ultrasonic technique for slow and void fraction measurements of two-phase flow

    International Nuclear Information System (INIS)

    Faccini, J.L.H.; Su, J.; Harvel, G.D.; Chang, J.S.

    2004-01-01

    In this paper, we present a hybrid type counterpropagating transmission ultrasonic technique (CPTU) for flow and time averaging ultrasonic transmission intensity void fraction measurements (TATIU) of air-water two-phase flow, which is tested in the new two-phase flow test section mounted recently onto an existing single phase flow rig. The circular pipe test section is made of 51.2 mm stainless steel, followed by a transparent extruded acrylic pipe aimed at flow visualization. The two-phase flow rig operates in several flow regimes: bubbly, smooth stratified, wavy stratified and slug flow. The observed flow patterns are compared with previous experimental and numerical flow regime map for horizontal two phase flows. These flow patterns will be identified by time averaging transmission intensity ultrasonic techniques which have been developed to meet this particular application. A counterpropagating transmission ultrasonic flowmeter is used to measure the flow rate of liquid phase. A pulse-echo TATIU ultrasonic technique used to measure the void fraction of the horizontal test section is presented. We can draw the following conclusions: 1) the ultrasonic system was able to characterize the 2 flow patterns simulated (stratified and plug flow); 2) the results obtained for water volumetric fraction require more experimental work to determine exactly the technique uncertainties but, a priori, they are consistent with earlier work; and 3) the experimental uncertainties can be reduced by improving the data acquisition system, changing the acquisition time interval from seconds to milliseconds

  7. 40 CFR Table 25 to Subpart G of... - Effective Column Diameter (Fc)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Effective Column Diameter (Fc) 25 Table..., Table 25 Table 25 to Subpart G of Part 63—Effective Column Diameter (Fc) Column type Fc (feet) 9-inch by 7-inch built-up columns 1.1 8-inch-diameter pipe columns 0.7 No construction details known 1.0 ...

  8. A diameter increment model for Red Fir in California and Southern Oregon

    Science.gov (United States)

    K. Leroy Dolph

    1992-01-01

    Periodic (10-year) diameter increment of individual red fir trees in Califomia and southern Oregon can be predicted from initial diameter and crown ratio of each tree, site index, percent slope, and aspect of the site. The model actually predicts the natural logarithm ofthe change in squared diameter inside bark between the startand the end of a 10-year growth period....

  9. Fractional bosonic strings

    Science.gov (United States)

    Diaz, Victor Alfonzo; Giusti, Andrea

    2018-03-01

    The aim of this paper is to present a simple generalization of bosonic string theory in the framework of the theory of fractional variational problems. Specifically, we present a fractional extension of the Polyakov action, for which we compute the general form of the equations of motion and discuss the connection between the new fractional action and a generalization the Nambu-Goto action. Consequently, we analyze the symmetries of the modified Polyakov action and try to fix the gauge, following the classical procedures. Then we solve the equations of motion in a simplified setting. Finally, we present a Hamiltonian description of the classical fractional bosonic string and introduce the fractional light-cone gauge. It is important to remark that, throughout the whole paper, we thoroughly discuss how to recover the known results as an "integer" limit of the presented model.

  10. Nutritional quality and fractionation of carbohydrates and protein in the forage components of an intensive silvopastoral system

    International Nuclear Information System (INIS)

    Gaviria, Xiomara; Rivera, J.E.; Barahona, R.

    2015-01-01

    The objective of this study was to evaluate the nutritional quality of the forage components of a SPSi based on Leucaena leucocephala associated to improved pastures, as well as its biomass production. The forage production was determined at several moments of the year and the nutritional quality was evaluated through the Cornell model. The soluble protein proportion (fraction A) was similar between the grasses and L. leucocephala, and represented as minimum 34 % of the total protein. The proportion of protein B2 (intermediate degradation) of the legume was higher than that of the grasses (53,7 vs. 30,2 %, respectively). Protein B3 of the diet (slow degradation) was around 22 % of the total protein, and more than 71 % of it can be considered degradable in rumen. L. leucocephala showed a higher concentration of soluble carbohydrates (16,7 %) and lower quantity of fraction B2 (14,94 %) than the grasses. Concerning the biomass availability, a production of 19,26 t DM/ha year-1 was reached. It is concluded that in SPSis a high quantity of quality forage is produced throughout the year, and that this offer is sufficient to cover the requirements of ruminants. (author)

  11. SU-F-T-205: Effectiveness of Robust Treatment Planning to Account for Inter- Fractional Variation in Intensity Modulated Proton Therapy for Head Neck Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Li, X; Zhang, J; Qin, A; Liang, J; Zhou, J; Yan, D; Chen, P; Krauss, D; Ding, X [Beaumont Health Systeml, Royal Oak, Michigan (United States)

    2016-06-15

    Purpose: To evaluate the potential benefits of robust optimization in intensity modulated proton therapy(IMPT) treatment planning to account for inter-fractional variation for Head Neck Cancer(HNC). Methods: One patient with bilateral HNC previous treated at our institution was used in this study. Ten daily CBCTs were selected. The CT numbers of the CBCTs were corrected by mapping the CT numbers from simulation CT via Deformable Image Registration. The planning target volumes(PTVs) were defined by a 3mm expansion from clinical target volumes(CTVs). The prescription was 70Gy, 54Gy to CTV1, CTV2, and PTV1, PTV2 for robust optimized(RO) and conventionally optimized(CO) plans respectively. Both techniques were generated by RayStation with the same beam angles: two anterior oblique and two posterior oblique angles. The similar dose constraints were used to achieve 99% of CTV1 received 100% prescription dose while kept the hotspots less than 110% of the prescription. In order to evaluate the dosimetric result through the course of treatment, the contours were deformed from simulation CT to daily CBCTs, modified, and approved by a radiation oncologist. The initial plan on the simulation CT was re-replayed on the daily CBCTs followed the bony alignment. The target coverage was evaluated using the daily doses and the cumulative dose. Results: Eight of 10 daily deliveries with using RO plan achieved at least 95% prescription dose to CTV1 and CTV2, while still kept maximum hotspot less than 112% of prescription compared with only one of 10 for the CO plan to achieve the same standards. For the cumulative doses, the target coverage for both RO and CO plans was quite similar, which was due to the compensation of cold and hot spots. Conclusion: Robust optimization can be effectively applied to compensate for target dose deficit caused by inter-fractional target geometric variation in IMPT treatment planning.

  12. Economic feasibility of products from inland West small-diameter timber

    Science.gov (United States)

    Spelter Henry; Rong Wang; Peter Ince

    1996-01-01

    A large part of the forests located in the Rocky Mountain region of the U.S. West (inland West) is characterized by densely packed, small-diameter stands. The purpose of this study was to examine the economic feasibility of using small-diameter material from this resource to manufacture various wood products: oriented strandboard (OSB), stud lumber, random-length...

  13. Fractional Dynamics and Control

    CERN Document Server

    Machado, José; Luo, Albert

    2012-01-01

    Fractional Dynamics and Control provides a comprehensive overview of recent advances in the areas of nonlinear dynamics, vibration and control with analytical, numerical, and experimental results. This book provides an overview of recent discoveries in fractional control, delves into fractional variational principles and differential equations, and applies advanced techniques in fractional calculus to solving complicated mathematical and physical problems.Finally, this book also discusses the role that fractional order modeling can play in complex systems for engineering and science. Discusses how fractional dynamics and control can be used to solve nonlinear science and complexity issues Shows how fractional differential equations and models can be used to solve turbulence and wave equations in mechanics and gravity theories and Schrodinger’s equation  Presents factional relaxation modeling of dielectric materials and wave equations for dielectrics  Develops new methods for control and synchronization of...

  14. Comparison of bolus versus fractionated oral applications of [13C]-linoleic acid in humans.

    Science.gov (United States)

    Demmelmair, H; Iser, B; Rauh-Pfeiffer, A; Koletzko, B

    1999-07-01

    The endogenous conversion of linoleic acid into long-chain polyunsaturated fatty acids is of potential importance for meeting substrate requirements, particularly in young infants. After application of [13C]-linoleic acid, we estimated its conversion to dihomo-gamma-linolenic and arachidonic acids from only two blood samples. Oral tracer doses were given to five healthy adults as a single bolus. In four subjects the tracer was given in nine equal portions over 3 days. Concentration and 13C content of fatty acids from serum phospholipids were analysed by gas chromatography combustion isotope ratio-mass spectrometry. Areas under the tracer-concentration curves were calculated, and fractional transfer and turnover rates estimated from compartmental models. The median fractional turnover of linoleic acid was 93.7% per day (interquartile range 25.3) in the bolus group and 80. 0% per day (6.3) in the fraction group (NS). Fractional conversion of linoleic to dihomo-gamma-linolenic acid was 1.5% (0.9) vs. 2.1% (0.7) (bolus vs. fraction, P /= 0.94, P < 0.05) with the ratio of areas under the curve. Using areas under the curve overestimates the conversion, because different residence times are not considered. Estimation of conversion intensity appears possible with only one blood sample obtained after tracer application.

  15. Solidification microstructures in a short fiber reinforced alloy composite containing different fiber fractions

    Directory of Open Access Journals (Sweden)

    JING Qing-xiu

    2006-02-01

    Full Text Available The solidification microstructures and micro-segregation of a fiber reinforced Al-9 Cu alloy, containing different volume fractions of Al2O3 short fibers about 6 μm diameter and made by squeeze casting have been studied. The results indicate that as volume fraction of fiber Vf increases, the size of final grains becomes finer in the matrix. If λf /λ>1, the fibers have almost no influence on the solidification behavior of the matrix, so the final grains grow coarse, where λf is the average inter-fiber spacing and λ is the secondary dendrite arm spacing. While if λf /λ<1, the growth of crystals in the matrix is affected significantly by the fibers and the grain size is reduced to the value of the inter-fiber spacing. The fibers influence the average length of a solidification volume element L of the matrix and also influence the solidification time θt of the matrix. As a result of fibers influencing L and θt, the micro-segregation in the matrix is improved when the composite contains more fibers, although the level of the improvement is slight. The Clyne-Kurz model can be used to semi-quantitatively analyze the relationship between Vf and the volume fraction fe of the micro-segregation eutectic structure.

  16. Evaluation of the normal thoracic and abdominal aorta diameters by computerized tomography

    International Nuclear Information System (INIS)

    Lucarelli, Claudio Luiz

    1995-01-01

    The study was undertaken to evaluate, through computerized tomography, the diameters of the normal thoracic and abdominal aorta, as well as they are connected to gender, age and body surface area; and the ratio between measurements obtained at the ascending and descending limbs of the thoracic aorta, and between the abdominal aortic diameters. For that reason, we measured the widest anteroposterior diameters of the thoracic aortas at the levels of the arch, the root, the pulmonary artery, and the thoracic-abdominal transition, as well as the level of the emergence of the superior mesenteric artery, of the renal hila and just cephalad to the bifurcation of the abdominal aortas of 350 patients without cardiovascular diseases who had undergone computerized tomography of the thorax and/or abdomen for any other reasons. Observation and statistic analyses led us to conclude that: 1) both the thoracic and abdominal aortic diameters are reduced from their proximal to their distal portions; 2) the body surface influences the size of the aorta, although only extreme variations alter the vessel's caliber; 3) vessel diameter was observed to gradually increase with age; 4) men were found to have larger diameters than age matched women; 5) the ratio between the ascending and descending aortic diameters varies according to gender and age; 6) the relations between abdominal aortic diameters measured at the level of renal hila and cephalad to the bifurcation are independent from gender and age. But the relation between those measured at the level of the superior mesenteric artery and cephalad to the bifurcation are linked to gender, but not to age. (author)

  17. Smarandache Continued Fractions

    OpenAIRE

    Ibstedt, H.

    2001-01-01

    The theory of general continued fractions is developed to the extent required in order to calculate Smarandache continued fractions to a given number of decimal places. Proof is given for the fact that Smarandache general continued fractions built with positive integer Smarandache sequences baving only a finite number of terms equal to 1 is convergent. A few numerical results are given.

  18. Fractional photothermolysis laser treatment of male pattern hair loss.

    Science.gov (United States)

    Kim, Won-Serk; Lee, Hye In; Lee, Jin Woong; Lim, Yun Young; Lee, Seung Jae; Kim, Beom Joon; Kim, Myeung Nam; Song, Kye Yong; Park, Won Serk

    2011-01-01

    Various trials have been conducted on the management of male pattern hair loss (MPHL). A variety of laser and light sources have been used for the treatment of MPHL. To understand the effects of a 1,550-nm fractional erbium-glass laser on the hair cycle in an alopecia mouse model and to study the clinical effects of the same laser used as treatment for MPHL. Irradiation was applied to the shaved skin of C3H/HeN mice using various energy and density settings and varied irradiation intervals. In a clinical pilot study involving human subjects, 20 participants were treated over five sessions at 2-week intervals. A fractional photothermolysis laser was used at the energy of 5 mJ and a total density of 300 spots/cm(2). In the animal study, the hair stimulation effects were dependent upon the energy level, density, and irradiation interval. The anagen conversion of hair and the increase in Wnt 5a, β-catenin signals were observed. In the human pilot study, incremental improvements in hair density and growth rate were observed. This pilot study showed that a 1,550-nm fractional erbium-glass laser might induce hair growth, but more intensive studies are required to clarify the clinical applications of this treatment. © 2010 by the American Society for Dermatologic Surgery, Inc.

  19. The Fogging Method with Variable of Nozle Diameter as the Mitigation Alternative for Spreading the Dust of Cement

    Science.gov (United States)

    Purwanta, J.; Marnoto, T.; Setyono, P.; Ramelan, A. H.

    2018-03-01

    The cement plant impacts on the lives of people around the factory site, one of them on the air quality, especially dust. Cement plant has made various efforts to mitigate dust generated, but the reality on the ground is still a lot of dust flying around either of the cement factory chimneys and transportation. The purpose of this study was to find the optimum condition of nozle diameter from the cement dust catcher, for mitigation the dust spread to around the cement plant. This study uses research methods such as collecting secondary data which includes data intensity rainfall, the average long rains, wind speed and direction as well as data quality monitoring dust around PT. Semen Gresik (Persero) Tbk. Tuban plant. To determine the wind direction propensity models, use a soft Windrose file. To determine the impact on the spread of dust into the environment using secondary data monitoring air quality. Results of the study is that the mitigation of dust around the cement plant is influenced by natural factors, namely the tendency of wind direction, rainfall and rainy days, and the rate of dust emission from the chimney. I try for operate the cement dust catcher with variable of nozle diameter. Finally, I find the optimum condition of nozle diameter for cement dust catcher is 1.40 mm, with line equation is y = 149.09.e 1.6237.x and error 5%. In that condition, nozle can make the fog with a good quality and it can catch the cement dust well.

  20. SEX DETERMINATION FROM FEMORAL HEAD DIAMETERS IN ...

    African Journals Online (AJOL)

    hi-tech

    2000-03-01

    Mar 1, 2000 ... In medico-legal cases where sophisticated methods of sex determination is lacking, these ... scientific methods(3). Using the visual method ... between the sexes and the values of the right and left femoral head diameters.

  1. A Fast Measuring Method for the Inner Diameter of Coaxial Holes.

    Science.gov (United States)

    Wang, Lei; Yang, Fangyun; Fu, Luhua; Wang, Zhong; Yang, Tongyu; Liu, Changjie

    2017-03-22

    A new method for fast diameter measurement of coaxial holes is studied. The paper describes a multi-layer measuring rod that installs a single laser displacement sensor (LDS) on each layer. This method is easy to implement by rotating the measuring rod, and immune from detecting the measuring rod's rotation angles, so all diameters of coaxial holes can be calculated by sensors' values. While revolving, the changing angles of each sensor's laser beams are approximately equal in the rod's radial direction so that the over-determined nonlinear equations of multi-layer holes for fitting circles can be established. The mathematical model of the measuring rod is established, all parameters that affect the accuracy of measurement are analyzed and simulated. In the experiment, the validity of the method is verified, the inner diameter measuring precision of 28 μm is achieved by 20 μm linearity LDS. The measuring rod has advantages of convenient operation and easy manufacture, according to the actual diameters of coaxial holes, and also the varying number of holes, LDS's mounting location can be adjusted for different parts. It is convenient for rapid diameter measurement in industrial use.

  2. Optical spectroscopy of iodine-doped single-wall carbon nanotubes of different diameter

    International Nuclear Information System (INIS)

    Tonkikh, Alexander A.; Obraztsova, Elena D.; Pozharov, Anatolii S.; Obraztsova, Ekaterina A.; Belkin, Alexey V.

    2012-01-01

    Single-wall carbon nanotubes with polyiodide chains inside are interesting from two points of view. According to predictions, first, the iodine structure type inside the nanotube is determined by the nanotube geometry. Second, after iodination all nanotubes become metallic. In this work, we made an attempt to check both predictions. To study the diameter-dependent properties we have taken for a gas-phase iodination the pristine single-wall carbon nanotubes grown by three different techniques providing a different average diameter: a chemical vapor deposition with a Co/Mo catalyst (CoMoCat) with a diameter range (0.6-1.3) nm, a high-pressure CO decomposition (HiPCO) - a diameter range (0.8-1.5) nm, and an aerosol technique with Fe catalyst - a diameter range (1.3-2.0) nm. The Raman spectra have shown a complication of the polyiodide chain structure while the nanotube diameter increased. The optical spectroscopy data (a suppression of E 11 band in the UV-Vis-NIR absorption spectrum) have confirmed the theoretical prediction about transformation of all nanotubes into metallic phase after doping. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Simulation on Effect of Preform Diameter in Injection Stretch Blow Molding

    Science.gov (United States)

    Tan, Z. Q.; Rosli, Nurrina; Oktaviandri, Muchamad

    2018-03-01

    Polyethylene terephthalate (PET) is the most common material of resin for manufacturing plastic bottle by injection stretch blow molding due to its excellent properties. As various issues of health and environmental hazards due to the PET use have risen, PET bottle manufacture may be improved by minimizing the wall thickness to reduce the PET use. One of the critical qualifications of the manufacturing process which lead to the wall thickness distribution is the initial preform diameter. In this project, we used the ANSYS Polyflow with aim to evaluate the wall thickness distribution of PET bottle for different diameter of initial preform. As a result, only 4 mm preform diameter presented wall thickness below than 1 mm. On the other hand, at least 6 mm preform diameter can permit the wall thickness 1.3 mm i.e. at the shoulder area.

  4. Decreasing diameter fluctuation of polymer optical fiber with optimized drawing conditions

    Science.gov (United States)

    Çetinkaya, Onur; Wojcik, Grzegorz; Mergo, Pawel

    2018-05-01

    The diameter fluctuations of poly(methyl methacrylate) based polymer optical fibers, during drawing processes, have been comprehensively studied. In this study, several drawing parameters were selected for investigation; such as drawing tensions, preform diameters, preform feeding speeds, and argon flows. Varied drawing tensions were used to draw fibers, while other parameters were maintained at constant. At a later stage in the process, micro-structured polymer optical fibers were drawn under optimized drawing conditions. Fiber diameter deviations were reduced to 2.2%, when a 0.2 N drawing tension was employed during the drawing process. Higher drawing tensions led to higher diameter fluctuations. The Young’s modulus of fibers drawn with different tensions was also measured. Our results showed that fiber elasticity increased as drawing tensions decreased. The inhomogeneity of fibers was also determined by comparing the deviation of Young’s modulus.

  5. Parametric Probability Distribution Functions for Axon Diameters of Corpus Callosum

    Directory of Open Access Journals (Sweden)

    Farshid eSepehrband

    2016-05-01

    Full Text Available Axon diameter is an important neuroanatomical characteristic of the nervous system that alters in the course of neurological disorders such as multiple sclerosis. Axon diameters vary, even within a fiber bundle, and are not normally distributed. An accurate distribution function is therefore beneficial, either to describe axon diameters that are obtained from a direct measurement technique (e.g., microscopy, or to infer them indirectly (e.g., using diffusion-weighted MRI. The gamma distribution is a common choice for this purpose (particularly for the inferential approach because it resembles the distribution profile of measured axon diameters which has been consistently shown to be non-negative and right-skewed. In this study we compared a wide range of parametric probability distribution functions against empirical data obtained from electron microscopy images. We observed that the gamma distribution fails to accurately describe the main characteristics of the axon diameter distribution, such as location and scale of the mode and the profile of distribution tails. We also found that the generalized extreme value distribution consistently fitted the measured distribution better than other distribution functions. This suggests that there may be distinct subpopulations of axons in the corpus callosum, each with their own distribution profiles. In addition, we observed that several other distributions outperformed the gamma distribution, yet had the same number of unknown parameters; these were the inverse Gaussian, log normal, log logistic and Birnbaum-Saunders distributions.

  6. Histological evaluation of vertical laser channels from ablative fractional resurfacing

    DEFF Research Database (Denmark)

    Skovbølling Haak, Christina; Illes, Monica; Paasch, Uwe

    2011-01-01

    Ablative fractional resurfacing (AFR) represents a new treatment potential for various skin conditions and new laser devices are being introduced. It is important to gain information about the impact of laser settings on the dimensions of the created laser channels for obtaining a safe...... and efficient treatment outcome. The aim of this study was to establish a standard model to document the histological tissue damage profiles after AFR and to test a new laser device at diverse settings. Ex vivo abdominal pig skin was treated with a MedArt 620, prototype fractional carbon dioxide (CO(2)) laser...... (Medart, Hvidovre, Denmark) delivering single microbeams (MB) with a spot size of 165 µm. By using a constant pulse duration of 2 ms, intensities of 1-18 W, single and 2-4 stacked pulses, energies were delivered in a range from 2-144 mJ/MB. Histological evaluations included 3-4 high-quality histological...

  7. Histological evaluation of vertical laser channels from ablative fractional resurfacing

    DEFF Research Database (Denmark)

    Skovbølling Haak, Christina; Illes, Monica; Paasch, Uwe

    2011-01-01

    Ablative fractional resurfacing (AFR) represents a new treatment potential for various skin conditions and new laser devices are being introduced. It is important to gain information about the impact of laser settings on the dimensions of the created laser channels for obtaining a safe...... and efficient treatment outcome. The aim of this study was to establish a standard model to document the histological tissue damage profiles after AFR and to test a new laser device at diverse settings. Ex vivo abdominal pig skin was treated with a MedArt 620, prototype fractional carbon dioxide (CO(2)) laser...... (Medart, Hvidovre, Denmark) delivering single microbeams (MB) with a spot size of 165 μm. By using a constant pulse duration of 2 ms, intensities of 1-18 W, single and 2-4 stacked pulses, energies were delivered in a range from 2-144 mJ/MB. Histological evaluations included 3-4 high-quality histological...

  8. Use of 1540nm fractionated erbium:glass laser for split skin graft resurfacing: a case study.

    Science.gov (United States)

    Narinesingh, S; Lewis, S; Nayak, B S

    2013-09-01

    The field of laser skin resurfacing has evolved rapidly over the past two decades from ablative lasers, to nonablative systems using near-infrared, intense-pulsed light and radio-frequency systems, and most recently fractional laser resurfacing. Although fractional thermolysis is still in its infancy, its efficacy in in the treatment of skin disorders have been clearly demonstrated. Here we present a case report on the safety and efficacy of a 1540nm erbium:glass laser in the treatment of the waffle pattern of a meshed skin graft in a 38-year-old patient with type V skin in the Caribbean.

  9. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

    International Nuclear Information System (INIS)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2015-01-01

    Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D L (0) and its rise-to-the-equilibrium curve H(L) = D L (0)/D eq from computed tomography (CT) scanning, where D eq is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm 3 thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E in /E or E out /E) on the phantom central and peripheral axes, where E = LD eq was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose ratios changed with beam aperture and

  10. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob, E-mail: bliu7@mgh.harvard.edu [Division of Diagnostic Imaging Physics and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States)

    2015-06-15

    Purpose: ICRU Report No. 87 Committee and AAPM Task Group 200 designed a three-sectional polyethylene phantom of 30 cm in diameter and 60 cm in length for evaluating the midpoint dose D{sub L}(0) and its rise-to-the-equilibrium curve H(L) = D{sub L}(0)/D{sub eq} from computed tomography (CT) scanning, where D{sub eq} is the equilibrium dose. To aid the use of the phantom in radiation dose assessment and to gain an understanding of dose equilibration and energy absorption in polyethylene, the authors evaluated the short (20 cm) to long (60 cm) phantom dose ratio with a polyethylene diameter of 30 cm, assessed H(L) in polyethylene cylinders of 6–55 cm in diameters, and examined energy absorption in these cylinders. Methods: A GEANT4-based Monte Carlo program was used to simulate the single axial scans of polyethylene cylinders (diameters 6–55 cm and length 90 cm, as well as diameter 30 cm and lengths 20 and 60 cm) on a clinical CT scanner (Somatom Definition dual source CT, Siemens Healthcare). Axial dose distributions were computed on the phantom central and peripheral axes. An average dose over the central 23 or 100 mm region was evaluated for modeling dose measurement using a 0.6 cm{sup 3} thimble chamber or a 10 cm long pencil ion chamber, respectively. The short (20 cm) to long (90 cm) phantom dose ratios were calculated for the 30 cm diameter polyethylene phantoms scanned at four tube voltages (80–140 kV) and a range of beam apertures (1–25 cm). H(L) was evaluated using the dose integrals computed with the 90 cm long phantoms. The resultant H(L) data were subsequently used to compute the fraction of the total energy absorbed inside or outside the scan range (E{sub in}/E or E{sub out}/E) on the phantom central and peripheral axes, where E = LD{sub eq} was the total energy absorbed along the z axis. Results: The midpoint dose in the 60 cm long polyethylene phantom was equal to that in the 90 cm long polyethylene phantom. The short-to-long phantom dose

  11. Inter fractional dose variation during intensity-modulated radiation therapy for cervical cancer assessed by weekly CT evaluation

    International Nuclear Information System (INIS)

    Han, Youngyih; Shin, Eun Hyuk; Huh, Seung Jae; Lee, Jung Eun; Park, Won

    2006-01-01

    Purpose: To investigate the inter fractional dose variation of a small-bowel displacement system (SBDS)-assisted intensity-modulated radiation therapy (IMRT) for the treatment of cervical cancer. Methods: Four computed tomography (CT) scans were carried out in 10 patients who received radiotherapy for uterine cervical cancer. The initial CT was taken by use of the SBDS, before the beginning of radiotherapy, and 3 additional CT scans with the SBDS were done in subsequent weeks. IMRT was planned by use of the initial CT, and the subsequent images were fused with the initial CT set. Dose-volume histogram (DVH) changes of the targets (planning target volume [PTV] = clinical target volume [CTV] + 1.5 cm) and of the critical organs were evaluated after obtaining the volumes of each organ on 4 CT sets. Results: No significant differences were found in PTV volumes. Changes on the DVH of the CTVs were not significant, whereas DVH changes of the PTVs at 40% to 100% of the prescription dose level were significant (V 90% ; 2nd week: p = 0.0091, 3rd week: p = 0.0029, 4th week: p = 0.0050). The changes in the small-bowel volume included in the treatment field were significant. These were 119.5 cm 3 (range, 26.9-251.0 cm 3 ), 126 cm 3 (range, 38.3-336 cm 3 ), 161.9 cm 3 (range, 37.7-294.6 cm 3 ), and 149.1 cm 3 (range, 38.6-277.8 cm 3 ) at the 1st, 2nd, 3rd, and 4th weeks, respectively, and were significantly correlated with the DVH change in the small bowel, which were significant at the 3rd (V 80% ; p = 0.0230) and 4th (V 80% ; p = 0.0263) weeks. The bladder-volume change correlated to the large volume change (>20%) of the small-bowel volume. Conclusions: Significant DVH differences for the small bowel can result because of interfractional position variations, whereas the DVH differences of the CTV were not significant. Strict bladder-filling control and an accurate margin for the PTV, as well as image-guided position verification, are important to achieve the goal of IMRT

  12. Fractionated radiosurgery for painful spinal metastases: DOSIS - a phase II trial

    OpenAIRE

    Guckenberger, Matthias; Hawkins, Maria; Flentje, Michael; Sweeney, Reinhart A.

    2013-01-01

    Abstract Background One third of all cancer patients will develop bone metastases and the vertebral column is involved in approximately 70% of these patients. Conventional radiotherapy with of 1–10 fractions and total doses of 8-30 Gy is the current standard for painful vertebral metastases; however, the median pain response is short with 3–6 months and local tumor control is limited with these rather low irradiation doses. Recent advances in radiotherapy technology – intensity modulated radi...

  13. Fractional high-harmonic combs by attosecond-precision split-spectrum pulse control

    Directory of Open Access Journals (Sweden)

    Laux Martin

    2013-03-01

    Full Text Available Few-cycle laser fields enable pulse-shaping control of high-order harmonic generation by time delaying variable broadband spectral sections. We report the experimental generation of fractional (noninteger high-harmonic combs by the controlled interference of two attosecond pulse trains. Additionally the energy of the high harmonics is strongly tuned with the relative time delay. We quantify the tuning to directly result from the controlled variation of the instantaneous laser frequency at the shaped driver pulse intensity maximum.

  14. Fire Intensity Data for Validation of the Radiative Transfer Equation

    Energy Technology Data Exchange (ETDEWEB)

    Blanchat, Thomas K. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jernigan, Dann A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    A set of experiments and test data are outlined in this report that provides radiation intensity data for the validation of models for the radiative transfer equation. The experiments were performed with lightly-sooting liquid hydrocarbon fuels that yielded fully turbulent fires 2 m diameter). In addition, supplemental measurements of air flow and temperature, fuel temperature and burn rate, and flame surface emissive power, wall heat, and flame height and width provide a complete set of boundary condition data needed for validation of models used in fire simulations.

  15. FRACTIONS: CONCEPTUAL AND DIDACTIC ASPECTS

    Directory of Open Access Journals (Sweden)

    Sead Rešić

    2016-09-01

    Full Text Available Fractions represent the manner of writing parts of whole numbers (integers. Rules for operations with fractions differ from rules for operations with integers. Students face difficulties in understanding fractions, especially operations with fractions. These difficulties are well known in didactics of Mathematics throughout the world and there is a lot of research regarding problems in learning about fractions. Methods for facilitating understanding fractions have been discovered, which are essentially related to visualizing operations with fractions.

  16. Diameter structure modeling and the calculation of plantation volume of black poplar clones

    Directory of Open Access Journals (Sweden)

    Andrašev Siniša

    2004-01-01

    Full Text Available A method of diameter structure modeling was applied in the calculation of plantation (stand volume of two black poplar clones in the section Aigeiros (Duby: 618 (Lux and S1-8. Diameter structure modeling by Weibull function makes it possible to calculate the plantation volume by volume line. Based on the comparison of the proposed method with the existing methods, the obtained error of plantation volume was less than 2%. Diameter structure modeling and the calculation of plantation volume by diameter structure model, by the regularity of diameter distribution, enables a better analysis of the production level and assortment structure and it can be used in the construction of yield and increment tables.

  17. Future prospects for stellar intensity interferometry

    International Nuclear Information System (INIS)

    Lake, R.J.W.

    2002-01-01

    Full text: The technique of Stellar Intensity lnterferometry (SII) was first successfully demonstrated by Hanbury-Brown in 1956 at Jodrell Bank. SII uses the correlation in intensity fluctuations of starlight as a function of observational baseline to determine angular diameters and other gross features of main sequence stars. In 1962 an observatory was established by Hanbury-Brown in Narrabri NSW. Between 1965 and 1972 the angular diameters of 32 stars covering the spectral range O to F were measured. Orbital parameters of several unresolved binary stars were also determined and attempts were made by the author to directly measure the limb darkening of Sirius and the rotational distortion of Altair. Following the success of the Narrabri SII the Australian Federal Government provided a grant to Sydney University to develop a Very Large SII capable of making observational measurements on about a thousand stars. The development of this VLSII was however shelved in preference to the development of a potentially more sensitive long baseline Michelson Stellar Interferometer. This latter instrument known as SUSI (Sydney University Stellar Interferometer) has been in operation at Narrabri since 1995. Encouraged by the early results of SUSI and their own efforts in the use of active optics to reduce the effects of atmospheric scintillation a number of international observatories are now active in the development of long baseline or large aperture Michelson Stellar Interferometers. However SII while sacrificing sensitivity has a number of technical advantages over MSI as SII is far less sensitive to atmospheric effects and can be readily developed to work over very long baselines. This paper through technical review and theoretical modeling examines how a modern VLSII could be constructed and operated and addresses the limitations to its sensitivity. In particular it examines how existing Australian industry could contribute to the development of a VLSII with sufficient

  18. Crown-Stump Diameter Model for Parkia biglobosa Benth. Species in Makurdi, Benue State, Nigeria

    Directory of Open Access Journals (Sweden)

    O. Chukwu

    2017-07-01

    Full Text Available The crown of tree is the centre of physiological activity which gives an indication of the potential photosynthetic capacity on a tree. Though, its measurement remains a challenge in forest inventory task. The ability to predict crown diameter from stump diameter provides an effective technique of obtaining its estimate. This helps in detecting the excessive tree felling than actual requirements and wildlife suitability.The main objective of this study was to develop and test crown diameter prediction models for silvicultural management of naturally grown Parkia biglobosa within the University of Agriculture, Makurdi. Nine 100 m x 100 m temporary sample plots were established using simple random sampling method. Crown diameter and stump diameter were measured in all living P. biglobosa trees with stump diameter ≥10.0 cm. Least square method was used to convert the counted stumps into harvested crown dimension. Three linear and three non-linear models using stump diameter as the exploratory variable were developed and evaluated using the adjusted coefficient of determination (Adj.R2, standard error of estimate (SEE, prediction error sum of squares (PRESS and Akaike information criterion (AIC. The crown-stump diameter relationship was best described by the double logarithmic function with .The result showed that Crown diameter estimation was feasible even when the only information available is stump diameter.The resulting equation was tested for validation with independent data obtained from additional plots and was found to be desirable for estimating the crown diameter for Parkia biglobosa in Makurdi, Benue State, Nigeria.

  19. Gauge invariant fractional electromagnetic fields

    International Nuclear Information System (INIS)

    Lazo, Matheus Jatkoske

    2011-01-01

    Fractional derivatives and integrations of non-integers orders was introduced more than three centuries ago but only recently gained more attention due to its application on nonlocal phenomenas. In this context, several formulations of fractional electromagnetic fields was proposed, but all these theories suffer from the absence of an effective fractional vector calculus, and in general are non-causal or spatially asymmetric. In order to deal with these difficulties, we propose a spatially symmetric and causal gauge invariant fractional electromagnetic field from a Lagrangian formulation. From our fractional Maxwell's fields arose a definition for the fractional gradient, divergent and curl operators. -- Highlights: → We propose a fractional Lagrangian formulation for fractional Maxwell's fields. → We obtain gauge invariant fractional electromagnetic fields. → Our generalized fractional Maxwell's field is spatially symmetrical. → We discuss the non-causality of the theory.

  20. Improved Design Basis for Laterally Loaded Large Diameter Pile

    DEFF Research Database (Denmark)

    Leth, Caspar Thrane

    of up-to-date facilities has been: Equipment for controlling centrifuge tests, data acquisition, preparation of test samples and equipment for and making of lateral load tests. The present research has been narrowed to investigate the static and cyclic behaviour of stiff piles with a diameter of 1-3 m...... in dry sand by use of centrifuge modelling and to compare the findings with the standard p-y curves. It has been chosen to apply piles with an embedment length of 6 to 10 times the diameter of the applied piles. The general static behaviour of monopiles in dry sand has based on centrifuge tests been...... with a capacity of 3.6 MW and placed at water depths beyond 25 m. Different foundation solutions have over the years been applied for offshore turbines, but monopiles are currently the most applied foundation type and are typically with a pile diameter of 4-6 m and applied up to a water depth of 25 m...

  1. Integral transform method for solving time fractional systems and fractional heat equation

    Directory of Open Access Journals (Sweden)

    Arman Aghili

    2014-01-01

    Full Text Available In the present paper, time fractional partial differential equation is considered, where the fractional derivative is defined in the Caputo sense. Laplace transform method has been applied to obtain an exact solution. The authors solved certain homogeneous and nonhomogeneous time fractional heat equations using integral transform. Transform method is a powerful tool for solving fractional singular Integro - differential equations and PDEs. The result reveals that the transform method is very convenient and effective.

  2. Measurement Of Multiphase Flow Water Fraction And Water-cut

    Science.gov (United States)

    Xie, Cheng-gang

    2007-06-01

    This paper describes a microwave transmission multiphase flow water-cut meter that measures the amplitude attenuation and phase shift across a pipe diameter at multiple frequencies using cavity-backed antennas. The multiphase flow mixture permittivity and conductivity are derived from a unified microwave transmission model for both water- and oil-continuous flows over a wide water-conductivity range; this is far beyond the capability of microwave-resonance-based sensors currently on the market. The water fraction and water cut are derived from a three-component gas-oil-water mixing model using the mixture permittivity or the mixture conductivity and an independently measured mixture density. Water salinity variations caused, for example, by changing formation water or formation/injection water breakthrough can be detected and corrected using an online water-conductivity tracking technique based on the interpretation of the mixture permittivity and conductivity, simultaneously measured by a single-modality microwave sensor.

  3. Helium Adsorption on Carbon Nanotube Bundles with Different Diameters:. Molecular Dynamics Simulation

    Science.gov (United States)

    Majidi, R.; Karami, A. R.

    2013-05-01

    We have used molecular dynamics simulation to study helium adsorption capacity of carbon nanotube bundles with different diameters. Homogeneous carbon nanotube bundles of (8,8), (9,9), (10,10), (11,11), and (12,12) single walled carbon nanotubes have been considered. The results indicate that the exohedral adsorption coverage does not depend on the diameter of carbon nanotubes, while the endohedral adsorption coverage is increased by increasing the diameter.

  4. Distal Ureteral Diameter Ratio is Predictive of Breakthrough Febrile Urinary Tract Infection.

    Science.gov (United States)

    Arlen, Angela M; Leong, Traci; Guidos, P Joseph; Alexander, Siobhan E; Cooper, Christopher S

    2017-12-01

    Distal ureteral diameter ratio is an objective measure that is prognostic of spontaneous resolution of vesicoureteral reflux. Along with likelihood of resolution, improved identification of children at risk for recurrent febrile urinary tract infections may impact management decisions. We evaluated the usefulness of ureteral diameter ratio as a predictive factor for breakthrough febrile urinary tract infections. Children with primary vesicoureteral reflux and detailed voiding cystourethrogram were identified. Ureteral diameter ratio was computed by measuring largest ureteral diameter within the pelvis and dividing by the distance between L1 and L3 vertebral bodies. Demographics, vesicoureteral reflux grade, laterality, presence/absence of bladder-bowel dysfunction, and ureteral diameter ratio were tested in univariate and multivariable analyses. Primary outcome was breakthrough febrile urinary tract infections. We analyzed 112 girls and 28 boys with a mean ± SD age of 2.5 ± 2.3 years at diagnosis. Vesicoureteral reflux was grade 1 to 2 in 64 patients (45.7%), grade 3 in 50 (35.7%), grade 4 in 16 (11.4%) and grade 5 in 10 (7.2%). Mean ± SD followup was 3.2 ± 2.7 years. A total of 40 children (28.6%) experienced breakthrough febrile urinary tract infections. Ureteral diameter ratio was significantly greater in children with (0.36) vs without (0.25) breakthrough febrile infections (p = 0.004). Controlling for vesicoureteral reflux grade, every 0.1 U increase in ureteral diameter ratio resulted in 1.7 times increased odds of breakthrough infection (95% CI 1.24 to 2.26, p urinary tract infections independent of reflux grade. Ureteral diameter ratio provides valuable prognostic information about risk of recurrent pyelonephritis and may assist with clinical decision-making. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. A Fractional Micro-Macro Model for Crowds of Pedestrians Based on Fractional Mean Field Games

    Institute of Scientific and Technical Information of China (English)

    Kecai Cao; Yang Quan Chen; Daniel Stuart

    2016-01-01

    Modeling a crowd of pedestrians has been considered in this paper from different aspects. Based on fractional microscopic model that may be much more close to reality, a fractional macroscopic model has been proposed using conservation law of mass. Then in order to characterize the competitive and cooperative interactions among pedestrians, fractional mean field games are utilized in the modeling problem when the number of pedestrians goes to infinity and fractional dynamic model composed of fractional backward and fractional forward equations are constructed in macro scale. Fractional micromacro model for crowds of pedestrians are obtained in the end.Simulation results are also included to illustrate the proposed fractional microscopic model and fractional macroscopic model,respectively.

  6. Gauge invariant fractional electromagnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Lazo, Matheus Jatkoske, E-mail: matheuslazo@furg.br [Instituto de Matematica, Estatistica e Fisica - FURG, Rio Grande, RS (Brazil)

    2011-09-26

    Fractional derivatives and integrations of non-integers orders was introduced more than three centuries ago but only recently gained more attention due to its application on nonlocal phenomenas. In this context, several formulations of fractional electromagnetic fields was proposed, but all these theories suffer from the absence of an effective fractional vector calculus, and in general are non-causal or spatially asymmetric. In order to deal with these difficulties, we propose a spatially symmetric and causal gauge invariant fractional electromagnetic field from a Lagrangian formulation. From our fractional Maxwell's fields arose a definition for the fractional gradient, divergent and curl operators. -- Highlights: → We propose a fractional Lagrangian formulation for fractional Maxwell's fields. → We obtain gauge invariant fractional electromagnetic fields. → Our generalized fractional Maxwell's field is spatially symmetrical. → We discuss the non-causality of the theory.

  7. On matrix fractional differential equations

    Directory of Open Access Journals (Sweden)

    Adem Kılıçman

    2017-01-01

    Full Text Available The aim of this article is to study the matrix fractional differential equations and to find the exact solution for system of matrix fractional differential equations in terms of Riemann–Liouville using Laplace transform method and convolution product to the Riemann–Liouville fractional of matrices. Also, we show the theorem of non-homogeneous matrix fractional partial differential equation with some illustrative examples to demonstrate the effectiveness of the new methodology. The main objective of this article is to discuss the Laplace transform method based on operational matrices of fractional derivatives for solving several kinds of linear fractional differential equations. Moreover, we present the operational matrices of fractional derivatives with Laplace transform in many applications of various engineering systems as control system. We present the analytical technique for solving fractional-order, multi-term fractional differential equation. In other words, we propose an efficient algorithm for solving fractional matrix equation.

  8. Fractionated radiosurgery for painful spinal metastases: DOSIS - a phase II trial

    Directory of Open Access Journals (Sweden)

    Guckenberger Matthias

    2012-11-01

    Full Text Available Abstract Background One third of all cancer patients will develop bone metastases and the vertebral column is involved in approximately 70% of these patients. Conventional radiotherapy with of 1–10 fractions and total doses of 8-30 Gy is the current standard for painful vertebral metastases; however, the median pain response is short with 3–6 months and local tumor control is limited with these rather low irradiation doses. Recent advances in radiotherapy technology – intensity modulated radiotherapy for generation of highly conformal dose distributions and image-guidance for precise treatment delivery – have made dose-escalated radiosurgery of spinal metastases possible and early results of pain and local tumor control are promising. The current study will investigate efficacy and safety of radiosurgery for painful vertebral metastases and three characteristics will distinguish this study. 1 A prognostic score for overall survival will be used for selection of patients with longer life expectancy to allow for analysis of long-term efficacy and safety. 2 Fractionated radiosurgery will be performed with the number of treatment fractions adjusted to either good (10 fractions or intermediate (5 fractions life expectancy. Fractionation will allow inclusion of tumors immediately abutting the spinal cord due to higher biological effective doses at the tumor - spinal cord interface compared to single fraction treatment. 3 Dose intensification will be performed in the involved parts of the vertebrae only, while uninvolved parts are treated with conventional doses using the simultaneous integrated boost concept. Methods / Design It is the study hypothesis that hypo-fractionated image-guided radiosurgery significantly improves pain relief compared to historic data of conventionally fractionated radiotherapy. Primary endpoint is pain response 3 months after radiosurgery, which is defined as pain reduction of ≥ 2 points at the treated

  9. FRACTIONS: CONCEPTUAL AND DIDACTIC ASPECTS

    OpenAIRE

    Sead Rešić; Ismet Botonjić; Maid Omerović

    2016-01-01

    Fractions represent the manner of writing parts of whole numbers (integers). Rules for operations with fractions differ from rules for operations with integers. Students face difficulties in understanding fractions, especially operations with fractions. These difficulties are well known in didactics of Mathematics throughout the world and there is a lot of research regarding problems in learning about fractions. Methods for facilitating understanding fractions have been discovered...

  10. Reduction of the Areolar Diameter After Ultrasound-Assisted Liposuction for Gynecomastia.

    Science.gov (United States)

    Keskin, Mustafa; Sutcu, Mustafa; Hanci, Mustafa; Cigsar, Bulent

    2017-08-01

    One of the clinical aspects characterizing gynecomastia is the enlargement of the nipple-areolar complex (NAC) due to hypertrophic breast glands, and the excessive fatty tissue underneath. The purpose of this study was to quantify the reduction of the areolar diameter after ultrasound-assisted liposuction (UAL) of the male breast. The horizontal diameters of the NACs of 30 men who underwent UAL were measured before surgery, 1 month after surgery and 6 months after surgery in a standard fashion. Those patients with surgical gland removals of any kind were not included in this study. The mean age of the patients was 27.9 years, and all of the patients had bilateral grade I, II, or III gynecomastia. The mean diameter of the NACs before surgery was 35.36 mm (range, 26-55 mm), and after surgery, the mean diameter of the NACs was initially reduced to 28.8 mm (range, 23-44 mm) and later to 28.57 mm (range, 23-42 mm). The mean volume of breast tissue aspirated was 382 mL per breast, and the percentage of reduction was 17.3%. The reduction of areola diameter was statistically significant after first month. A significant positive correlation was identified between the liposuction volume and areolar diameter reduction. In cases of gynecomastia, the removal of the glandular and fatty tissue underneath the areola releases the expanding forces and pressure that enlarge it. In many cases of gynecomastia, UAL alone is effective in reducing the size of the NAC and allows the surgeon to avoid placing scars on the breast.

  11. Numerical analysis of the bubble detachment diameter in nucleate boiling

    International Nuclear Information System (INIS)

    Lamas, M I; Sáiz Jabardo, J M; Arce, A; Fariñas, P

    2012-01-01

    The present paper presents a tri-dimensional CFD (Computational Fluid Dynamics) model to investigate the fluid flow around bubbles attached to heated walls. Transient solutions of the governing field equations in a domain containing the bubbles and the surrounding liquid have been obtained. The nucleation, growing and detachment processes have been analyzed. Concerning the software, the open source OpenFOAM has been used. Special attention has been given to the bubble detachment diameter. Two mechanisms have been considered as physically related to the detachment: surface tension and buoyancy. As expected, it has been verified that the bubble detachment diameter depends on the contact angle, operating pressure and properties of the fluid. Several fluids have been considered (water, R134a, ammonia and R123), as well as several operating pressures (between 0.1 and 10 bar) and contact angles (between 10 and 80°). It has been concluded that the detachment diameter depends strongly on the contact angle and fluid properties and slightly on the pressure. A correlation for the bubble detachment diameter has been developed based on the obtained numerical results. Data from this expression compare reasonably well with those from other correlations from the literature.

  12. A feasibility study: Selection of a personalized radiotherapy fractionation schedule using spatiotemporal optimization

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Minsun, E-mail: mk688@uw.edu; Stewart, Robert D. [Department of Radiation Oncology, University of Washington, Seattle, Washington 98195-6043 (United States); Phillips, Mark H. [Departments of Radiation Oncology and Neurological Surgery, University of Washington, Seattle, Washington 98195-6043 (United States)

    2015-11-15

    Purpose: To investigate the impact of using spatiotemporal optimization, i.e., intensity-modulated spatial optimization followed by fractionation schedule optimization, to select the patient-specific fractionation schedule that maximizes the tumor biologically equivalent dose (BED) under dose constraints for multiple organs-at-risk (OARs). Methods: Spatiotemporal optimization was applied to a variety of lung tumors in a phantom geometry using a range of tumor sizes and locations. The optimal fractionation schedule for a patient using the linear-quadratic cell survival model depends on the tumor and OAR sensitivity to fraction size (α/β), the effective tumor doubling time (T{sub d}), and the size and location of tumor target relative to one or more OARs (dose distribution). The authors used a spatiotemporal optimization method to identify the optimal number of fractions N that maximizes the 3D tumor BED distribution for 16 lung phantom cases. The selection of the optimal fractionation schedule used equivalent (30-fraction) OAR constraints for the heart (D{sub mean} ≤ 45 Gy), lungs (D{sub mean} ≤ 20 Gy), cord (D{sub max} ≤ 45 Gy), esophagus (D{sub max} ≤ 63 Gy), and unspecified tissues (D{sub 05} ≤ 60 Gy). To assess plan quality, the authors compared the minimum, mean, maximum, and D{sub 95} of tumor BED, as well as the equivalent uniform dose (EUD) for optimized plans to conventional intensity-modulated radiation therapy plans prescribing 60 Gy in 30 fractions. A sensitivity analysis was performed to assess the effects of T{sub d} (3–100 days), tumor lag-time (T{sub k} = 0–10 days), and the size of tumors on optimal fractionation schedule. Results: Using an α/β ratio of 10 Gy, the average values of tumor max, min, mean BED, and D{sub 95} were up to 19%, 21%, 20%, and 19% larger than those from conventional prescription, depending on T{sub d} and T{sub k} used. Tumor EUD was up to 17% larger than the conventional prescription. For fast proliferating

  13. Effects of naturally occurring aquatic organic fractions on 241Am uptake by Scenedesmus obliquus (Chlorophyceae) and Aeromonas hydrophila (Pseudomonadaceae)

    International Nuclear Information System (INIS)

    Giesy, J.P. Jr.; Paine, D.

    1977-01-01

    Naturally occurring organics were extracted from water collected from Skinface Pond near Aiken, S.C. Organics were separated into four nominal diameter size fractions (I, greater than 0.0183; II, 0.0183 to 0.0032; III, 0.0032 to 0.0009; IV, less than 0.0009 μm) by membrane ultrafiltration and introduced into Scenedesmus obliquus and Aeromonas hydrophila cultures to determine their effects on 241 Am availability for uptake. Effects on 241 Am uptake were determined in actively growing S. obliquus cultures after 96 h of growth and in dense cultures of nongrowing cells after 4 h. Uptake by A. hydrophila was determined after 4 and 24 h in actively growing cultures. All organic fractions stimulated S. obliquus growth, with the most pronounced effects due to larger organic fractions, whereas no apparent growth stimulation of A. hydrophila was observed for any organic fraction. For both long-term and short-term studies, cellular 241 Am concentration (picocuries/cell) increased with increasing 241 Am concentration for S. obliquus and A. hydrophila. Fraction IV increased 241 Am uptake by both S. obliquus and A. hydrophila during 4-h incubations. During 96-h incubations fraction I was flocculated and cosedimented, with S. obliquus and A. hydrophila cells causing an apparent increase in 241 Am uptake. Fractions II and III reduced apparent 241 Am uptake by S. obliquus as a result of biological dilution caused by increased algal growth due to the organics. Fraction IV caused a reduction in 241 Am uptake by S. obliquus not attributable to biological dilution. Organics increased 241 Am uptake by A. hydrophila during 4- and 24-h incubations. A. hydrophila also caused flocculation of fraction I during 96-h incubations

  14. A New Fractional Projective Riccati Equation Method for Solving Fractional Partial Differential Equations

    International Nuclear Information System (INIS)

    Feng Qing-Hua

    2014-01-01

    In this paper, a new fractional projective Riccati equation method is proposed to establish exact solutions for fractional partial differential equations in the sense of modified Riemann—Liouville derivative. This method can be seen as the fractional version of the known projective Riccati equation method. For illustrating the validity of this method, we apply this method to solve the space-time fractional Whitham—Broer—Kaup (WBK) equations and the nonlinear fractional Sharma—Tasso—Olever (STO) equation, and as a result, some new exact solutions for them are obtained. (general)

  15. METHODS OF CONTROLLING THE AVERAGE DIAMETER OF THE THREAD WITH ASYMMETRICAL PROFILE

    Directory of Open Access Journals (Sweden)

    L. M. Aliomarov

    2015-01-01

    Full Text Available To handle the threaded holes in hard materials made of marine machinery, operating at high temperatures, heavy loads and in aggressive environments, the authors have developed the combined tool core drill -tap with a special cutting scheme, which has an asymmetric thread profile on the tap part. In order to control the average diameter of the thread of tap part of the combined tool was used the method three wires, which allows to make continuous measurement of the average diameter of the thread along the entire profile. Deviation from the average diameter from the sample is registered by inductive sensor and is recorded by the recorder. In the work are developed and presented control schemes of the average diameter of the threads with a symmetrical and asymmetrical profile. On the basis of these schemes are derived formulas for calculating the theoretical option to set the wires in the thread profile in the process of measuring the average diameter. Conducted complex research and the introduction of the combined instrument core drill-tap in the production of products of marine engineering, shipbuilding, ship repair power plants made of hard materials showed a high efficiency of the proposed technology for the processing of high-quality small-diameter threaded holes that meet modern requirements.

  16. Onset of Intense Surface Enhanced Raman Scattering and Aggregation in the Au@Ag System

    Directory of Open Access Journals (Sweden)

    Priya Bhatia

    2015-01-01

    Full Text Available Gold core/silver shell (Au@Ag nanoparticles of ~37 ± 5 nm diameter generate intense SERS (λEX=785 nm responses in solution when they interact with the SERS labels rhodamine 6G (R6G, 4-mercaptopyridine (MPY, and 4-mercaptobenzoic acid (MBA. Herein the relationship between SERS intensity, aggregation, and adsorption phenomenon isobserved by titrating Au@Ag with the above labels. As the labels adsorb to the Au@Ag, they drive aggregation as evidenced by the creation of NIR extinction peaks, and the magnitude of this NIR extinction (measured at 830 nm correlates very closely to magnitude of the intense SERS signals. The label MBA is an exception since it does not trigger aggregation nor does it result in intense SERS; rather intense SERS is recovered only after MBA coated Au@Ag is aggregated with KCl. An “inner filter” model is introduced and applied to compensate for solution extinction when the exciting laser radiation is significantly attenuated. This model permits a summary of the SERS responses in the form of plots of SERS intensity versus the aggregate absorption at 830 nm, which shows the excellent correlation between intense SERS and LSPR bands extinction.

  17. Production of a large diameter ECR plasma with low electron temperature

    International Nuclear Information System (INIS)

    Koga, Mayuko; Hishikawa, Yasuhiro; Tsuchiya, Hayato; Kawai, Yoshinobu

    2006-01-01

    A large diameter plasma over 300 mm in diameter is produced by electron cyclotron resonance (ECR) discharges using a cylindrical vacuum chamber of 400 mm in inner diameter. It is found that the plasma uniformity is improved by adding the nitrogen gas to pure Ar plasma. The electron temperature is decreased by adding the nitrogen gas. It is considered that the electron energy is absorbed in the vibrational energy of nitrogen molecules and the electron temperature decreases. Therefore, the adjunction of the nitrogen gas is considered to be effective for producing uniform and low electron temperature plasma

  18. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  19. Measured Performance of a Varied Airflow Small-Diameter Duct System

    Energy Technology Data Exchange (ETDEWEB)

    Poerschke, Andrew [IBACOS, Inc., Pittsburgh, PA (United States)

    2017-03-16

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

  20. Three-dimensional vortex flow near the endwall of a short cylinder in crossflow: Uniform-diameter circular cylinder

    International Nuclear Information System (INIS)

    Chen, S.B.; Sanitjai, S.; Ghosh, K.; Goldstein, R.J.

    2012-01-01

    Flow characteristics, around a short uniform-diameter circular cylinder in crossflow, are investigated experimentally. Extensive flow visualization using oil-lampblack and smoke-wire methods have been performed. Near-wake velocity measurements have been performed using a hotwire anemometer. Complex secondary flows are observed on and around the cylinder in crossflow. Multiple vortices are observed in the horseshoe vortex system near the cylinder–endwall junction. Based on this flow visualization and local mass transfer measurement results, a six-vortex secondary flow model has been proposed. - Highlights: ► Flow visualizations and velocity measurements for a short circular cylinder. ► Six vortices in the horseshoe vortex system upstream of the base of the cylinder. ► Cross-stream turbulence intensity profiles show a similarity in their shape.

  1. Evaluation of photo destruction of chromophores of heme and globin components in UV-irradiated human carboxyhemoglobin and its electrophoretic fractions

    International Nuclear Information System (INIS)

    Putintseva, O.V.; Artykhov, V.G.; Kalaeva, E.A.

    2000-01-01

    The contribution of hem and globin components of electrophoretic fractions of UV-irradiated human carboxyhemoglobin to photo destruction of the protein was studied. The changes observed are the result of summation of some processes unequal in intensity and direction that take place in microgeterogenous media of photo modified protein. Photo sensitivity of hemoproteid in electrophoretic fraction depends on apoprotein condition, whereas the hem photo resistance cannot be the evidence of the photo stability of the whole molecule [ru

  2. FNAL Booster intensity, extraction, and synchronization control for collider operation

    International Nuclear Information System (INIS)

    Ducar, R.J.; Lackey, J.R.; Tawzer, S.R.

    1987-03-01

    Booster operation for collider physics is considerably different than for fixed target operation. Various scenarios for collider physics, machine studies, and P-Bar targeting may require that the intensity vary from 5E10 PPP to 3E12 PPP at a 15 Hertz machine cycle rate. In addition to the normal Booster single turn extraction mode, collider operations require that the Booster inject into the Main Ring a small number of beam bunches for coalescing into a single high intensity bunch. These bunches must be synchronized such that the center bunch arrives in the RF bucket which corresponds to the zero phase of the coalescing cavity. The system implemented has the ability to deliver a precise fraction of the available 84 Booster beam bunches to Main Ring or to the P-Bar Debuncher via the newly installed AP-4 beam line for tune-up and studies. It is required that all of the various intensity and extraction scenarios be accommodated with minimal operator intervention

  3. Diameter Tuning of β-Ga2O3 Nanowires Using Chemical Vapor Deposition Technique.

    Science.gov (United States)

    Kumar, Mukesh; Kumar, Vikram; Singh, R

    2017-12-01

    Diameter tuning of [Formula: see text]-Ga 2 O 3 nanowires using chemical vapor deposition technique have been investigated under various experimental conditions. Diameter of root grown [Formula: see text]-Ga 2 O 3 nanowires having monoclinic crystal structure is tuned by varying separation distance between metal source and substrate. Effect of gas flow rate and mixer ratio on the morphology and diameter of nanowires has been studied. Nanowire diameter depends on growth temperature, and it is independent of catalyst nanoparticle size at higher growth temperature (850-900 °C) as compared to lower growth temperature (800 °C). These nanowires show changes in structural strain value with change in diameter. Band-gap of nanowires increases with decrease in the diameter.

  4. Increased response to glutamate in small diameter dorsal root ganglion neurons after sciatic nerve injury.

    Directory of Open Access Journals (Sweden)

    Kerui Gong

    Full Text Available Glutamate in the peripheral nervous system is involved in neuropathic pain, yet we know little how nerve injury alters responses to this neurotransmitter in primary sensory neurons. We recorded neuronal responses from the ex-vivo preparations of the dorsal root ganglia (DRG one week following a chronic constriction injury (CCI of the sciatic nerve in adult rats. We found that small diameter DRG neurons (30 µm were unaffected. Puff application of either glutamate, or the selective ionotropic glutamate receptor agonists alpha-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid (AMPA and kainic acid (KA, or the group I metabotropic receptor (mGluR agonist (S-3,5-dihydroxyphenylglycine (DHPG, induced larger inward currents in CCI DRGs compared to those from uninjured rats. N-methyl-D-aspartate (NMDA-induced currents were unchanged. In addition to larger inward currents following CCI, a greater number of neurons responded to glutamate, AMPA, NMDA, and DHPG, but not to KA. Western blot analysis of the DRGs revealed that CCI resulted in a 35% increase in GluA1 and a 60% decrease in GluA2, the AMPA receptor subunits, compared to uninjured controls. mGluR1 receptor expression increased by 60% in the membrane fraction, whereas mGluR5 receptor subunit expression remained unchanged after CCI. These results show that following nerve injury, small diameter DRG neurons, many of which are nociceptive, have increased excitability and an increased response to glutamate that is associated with changes in receptor expression at the neuronal membrane. Our findings provide further evidence that glutamatergic transmission in the periphery plays a role in nociception.

  5. Cesium and strontium fractionation from HLW for thermal-stress reduction in a geologic repository

    International Nuclear Information System (INIS)

    McKee, R.W.

    1983-02-01

    Results are described for a study to assess the benefits and costs of fractionating the cesium and strontium components in commercial high-level waste (HLW) to a separate waste stream for the purpose of reducing geologic repository thermal stresses. System costs are developed for a broad range of conditions comparing the Cs/Sr fractionation concept with disposal of 10-year old vitrified HLW and vitrified HLW aged to achieve (through decay) the same heat output as the fractionated high-level waste (FHLW). All comparisons are based on a 50,000 metric ton equivalent (MTE) system. The FHLW and the Cs/Sr waste are both disposed of a vitrified waste but emplaced in separate areas of a basalt repository. The FHLW is emplaced in high-integrity packages at relatively high waste loading but low heat loading, while the Cs/Sr waste is emplaced in minimum integrity packages at relatively high heat loading. System cost comparisons are based on minimum cost combinations of canister diameter, waste concentration, and canister spacing in a basalt repository for each waste type. The effects on both long- and near-term safety considerations are also addressed. The major conclusion is that the Cs/Sr fractionation concept offers, potentially, a substantial total system cost advantage for HLW disposal if reduced HLW package temperatures in a basalt repository are desired. However, there is no cost advantage if currently designated maximum design temperatures are acceptable. Aging the HLW for 50 to 100 years can accomplish similar results at equivalent or loser costs

  6. Stability of phospholipid vesicles studied by asymmetrical flow field-flow fractionation and capillary electrophoresis

    Energy Technology Data Exchange (ETDEWEB)

    Yohannes, Gebrenegus [Laboratory of Analytical Chemistry, Department of Chemistry, P.O. Box 55, FIN-00014 University of Helsinki (Finland); Pystynen, Kati-Henna [Laboratory of Analytical Chemistry, Department of Chemistry, P.O. Box 55, FIN-00014 University of Helsinki (Finland); Riekkola, Marja-Liisa [Laboratory of Analytical Chemistry, Department of Chemistry, P.O. Box 55, FIN-00014 University of Helsinki (Finland); Wiedmer, Susanne K. [Laboratory of Analytical Chemistry, Department of Chemistry, P.O. Box 55, FIN-00014 University of Helsinki (Finland)]. E-mail: susanne.wiedmer@helsinki.fi

    2006-02-23

    The stability of zwitterionic phosphatidylcholine vesicles in the presence of 20 mol% phosphatidyl serine (PS), phosphatidic acid (PA), phosphatidyl inositol (PI), and diacylphosphatidyl glycerol (PG) phospholipid vesicles, and cholesterol or calcium chloride was investigated by asymmetrical flow field-flow fractionation (AsFlFFF). Large unilamellar vesicles (LUV, diameter 100 nm) prepared by extrusion at 25 deg. C were used. Phospholipid vesicles (liposomes) were stored at +4 and -18 deg. C over an extended period of time. Extruded egg yolk phosphatidylcholine (EPC) particle diameters at peak maximum and mean measured by AsFlFFF were 101 {+-} 3 nm and 122 {+-} 5 nm, respectively. No significant change in diameter was observed after storage at +4 deg. C for about 5 months. When the storage period was extended to about 8 months (250 days) larger destabilized aggregates were formed (172 and 215 nm at peak maximum and mean diameters, respectively). When EPC was stored at -18 deg. C, large particles with diameters of 700-800 nm were formed as a result of dehydration, aggregation, and fusion processes. In the presence of calcium chloride, EPC alone did not form large aggregates. Addition of 20 mol% of negatively charged phospholipids (PS, PA, PI, or PG) to 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphatidylcholine (POPC) vesicles increased the electrostatic interactions between calcium ion and the vesicles and large aggregates were formed. In the presence of cholesterol, large aggregates of about 250-350 nm appeared during storage at +4 and -18 deg. C for more than 1 day. The effect of liposome storage temperature on phospholipid coatings applied in capillary electrophoresis (CE) was studied by measuring the electroosmotic flow (EOF). EPC coatings with and without cholesterol, PS, or calcium chloride, prepared from liposomes stored at +25, +4, and -18 deg. C, were studied at 25 deg. C. The performances of the coatings were further evaluated with three uncharged compounds

  7. The AKARI IRC asteroid flux catalogue: updated diameters and albedos

    Science.gov (United States)

    Alí-Lagoa, V.; Müller, T. G.; Usui, F.; Hasegawa, S.

    2018-05-01

    The AKARI IRC all-sky survey provided more than twenty thousand thermal infrared observations of over five thousand asteroids. Diameters and albedos were obtained by fitting an empirically calibrated version of the standard thermal model to these data. After the publication of the flux catalogue in October 2016, our aim here is to present the AKARI IRC all-sky survey data and discuss valuable scientific applications in the field of small body physical properties studies. As an example, we update the catalogue of asteroid diameters and albedos based on AKARI using the near-Earth asteroid thermal model (NEATM). We fit the NEATM to derive asteroid diameters and, whenever possible, infrared beaming parameters. We fit groups of observations taken for the same object at different epochs of the survey separately, so we compute more than one diameter for approximately half of the catalogue. We obtained a total of 8097 diameters and albedos for 5170 asteroids, and we fitted the beaming parameter for almost two thousand of them. When it was not possible to fit the beaming parameter, we used a straight line fit to our sample's beaming parameter-versus-phase angle plot to set the default value for each fit individually instead of using a single average value. Our diameters agree with stellar-occultation-based diameters well within the accuracy expected for the model. They also match the previous AKARI-based catalogue at phase angles lower than 50°, but we find a systematic deviation at higher phase angles, at which near-Earth and Mars-crossing asteroids were observed. The AKARI IRC All-sky survey is an essential source of information about asteroids, especially the large ones, since, it provides observations at different observation geometries, rotational coverages and aspect angles. For example, by comparing in more detail a few asteroids for which dimensions were derived from occultations, we discuss how the multiple observations per object may already provide three

  8. Experimental Studies of Turbulent Intensity around a Tidal Turbine Support Structure

    Directory of Open Access Journals (Sweden)

    Stuart Walker

    2017-04-01

    Full Text Available Tidal stream energy is a low-carbon energy source. Tidal stream turbines operate in a turbulent environment, and the effect of the structure between the turbine and seabed on this environment is not fully understood. An experimental study using 1:72 scale models based on a commercial turbine design was carried out to study the support structure influence on turbulent intensity around the turbine blades. The study was conducted using the wave-current tank at the Laboratory of Maritime Engineering (LABIMA, University of Florence. A realistic flow environment (ambient turbulent intensity = 11% was established. Turbulent intensity was measured upstream and downstream of a turbine mounted on two different support structures (one resembling a commercial design, the other the same with an additional vertical element, in order to quantify any variation in turbulence and performance between the support structures. Turbine drive power was used to calculate power generation. Acoustic Doppler velocimetry (ADV was used to record and calculate upstream and downstream turbulent intensity. In otherwise identical conditions, performance variation of only 4% was observed between two support structures. Turbulent intensity at 1, 3 and 5 blade diameters, both upstream and downstream, showed variation up to 21% between the two cases. The additional turbulent structures generated by the additional element of the second support structure appears to cause this effect, and the upstream propagation of turbulent intensity is believed to be permitted by surface waves. This result is significant for the prediction of turbine array performance.

  9. A fractional model with parallel fractional Maxwell elements for amorphous thermoplastics

    Science.gov (United States)

    Lei, Dong; Liang, Yingjie; Xiao, Rui

    2018-01-01

    We develop a fractional model to describe the thermomechanical behavior of amorphous thermoplastics. The fractional model is composed of two parallel fractional Maxwell elements. The first fractional Maxwell model is used to describe the glass transition, while the second component is aimed at describing the viscous flow. We further derive the analytical solutions for the stress relaxation modulus and complex modulus through Laplace transform. We then demonstrate the model is able to describe the master curves of the stress relaxation modulus, storage modulus and loss modulus, which all show two distinct transition regions. The obtained parameters show that the modulus of the two fractional Maxwell elements differs in 2-3 orders of magnitude, while the relaxation time differs in 7-9 orders of magnitude. Finally, we apply the model to describe the stress response of constant strain rate tests. The model, together with the parameters obtained from fitting the master curve of stress relaxation modulus, can accurately predict the temperature and strain rate dependent stress response.

  10. Permutation entropy of fractional Brownian motion and fractional Gaussian noise

    International Nuclear Information System (INIS)

    Zunino, L.; Perez, D.G.; Martin, M.T.; Garavaglia, M.; Plastino, A.; Rosso, O.A.

    2008-01-01

    We have worked out theoretical curves for the permutation entropy of the fractional Brownian motion and fractional Gaussian noise by using the Bandt and Shiha [C. Bandt, F. Shiha, J. Time Ser. Anal. 28 (2007) 646] theoretical predictions for their corresponding relative frequencies. Comparisons with numerical simulations show an excellent agreement. Furthermore, the entropy-gap in the transition between these processes, observed previously via numerical results, has been here theoretically validated. Also, we have analyzed the behaviour of the permutation entropy of the fractional Gaussian noise for different time delays

  11. Control and Synchronization of the Fractional-Order Lorenz Chaotic System via Fractional-Order Derivative

    Directory of Open Access Journals (Sweden)

    Ping Zhou

    2012-01-01

    Full Text Available The unstable equilibrium points of the fractional-order Lorenz chaotic system can be controlled via fractional-order derivative, and chaos synchronization for the fractional-order Lorenz chaotic system can be achieved via fractional-order derivative. The control and synchronization technique, based on stability theory of fractional-order systems, is simple and theoretically rigorous. The numerical simulations demonstrate the validity and feasibility of the proposed method.

  12. Ureteral diameter in low-risk vesicoureteral reflux in infancy and childhood

    International Nuclear Information System (INIS)

    Hellstroem, M.; Hjaelmaas, K.; Jacobsson, B.; Jodal, U.; Oestra Sjukhuset, Goeteborg; Oestra Sjukhuset, Goeteborg

    1986-01-01

    In order to improve the accuracy of the grading of vesicoureteral reflux (VUR), reference values for ureteral diameter at micturition cystourethrography (MCUG) were established in infants and children with low-risk VUR. Low-risk VUR was defined as VUR not associated with infection, obstruction, calculi, duplication, malformations (except for hypospadia) or neurogenic bladder disturbances. Forty-six children (age 1 day - 14 years) were selected by examining the records of 12000 MCUG:s performed 1960-1983. Ureteral diameter was measured at the widest point of the ureter on the films from MCUG:s and urographies. Ureteral diameter was slightly larger at MCUG than at urography in the same individuals but the difference was not significant. The ureteral diameter at MCUG also correlated closely to normal values at urography in a previous study. It is proposed that the reference values obtained at MCUG in the present investigation can be used for the differentiation between dilatation and no dilatation in the grading of VUR. (orig.)

  13. -Dimensional Fractional Lagrange's Inversion Theorem

    Directory of Open Access Journals (Sweden)

    F. A. Abd El-Salam

    2013-01-01

    Full Text Available Using Riemann-Liouville fractional differential operator, a fractional extension of the Lagrange inversion theorem and related formulas are developed. The required basic definitions, lemmas, and theorems in the fractional calculus are presented. A fractional form of Lagrange's expansion for one implicitly defined independent variable is obtained. Then, a fractional version of Lagrange's expansion in more than one unknown function is generalized. For extending the treatment in higher dimensions, some relevant vectors and tensors definitions and notations are presented. A fractional Taylor expansion of a function of -dimensional polyadics is derived. A fractional -dimensional Lagrange inversion theorem is proved.

  14. Assessment Using ANL Experiments on Void Fraction in a Vertical Tube

    Energy Technology Data Exchange (ETDEWEB)

    Han, KyuHyun; Bang, YoungSeok [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2015-05-15

    A licensing application of a safety analysis code, SPACE, was submitted and is currently under KINS' review. This code was developed to consider three fluid fields, i.e. liquid, vapor and droplet, for a realistic simulation of accident phenomena. Therefore, there may be a concern that this code could predict different behavior compared to the existing codes. To assess the important performance independently and to compare with prediction results of SPACE might be helpful to regulatory review for identifying validity of the code. The interfacial friction could largely affect prediction of thermal hydraulic phenomena during LOCA or non- LOCA. This paper provides MARS-KS prediction of void fraction experiments in a vertical tube by ANL and compares with SPACE prediction results. It was found that the similar interfacial friction model adopting the drift flux correlations were implemented in both codes. Experimental void fractions of the ANL test presented in this paper correspond to bubbly, slug and churn flow regions. Agreements in general sense between the experiment and the predicted values were identified through calculations. Thus, similar accuracy for this experiment can be expected in SPACE and MARS-KS. It was also shown that drift flux interfacial friction model for intermediate flow channel (diameter of 7cm) is valid.

  15. Anatomic radiological study of transverse diameter of abdominal aorta by computerized tomography

    International Nuclear Information System (INIS)

    Ures, S.

    1984-01-01

    The transverse diameter of abdominal aorta by computerized tomography is studied. The purpose is establish the frequent standard diameters and then diagnose early pathologies, mainly aneurisms. (M.A.C.) [pt

  16. Accumulation, translocation and impact of TiO{sub 2} nanoparticles in wheat (Triticum aestivum spp.): Influence of diameter and crystal phase

    Energy Technology Data Exchange (ETDEWEB)

    Larue, Camille, E-mail: camille.larue@cea.fr [UMR3299 CEA-CNRS, Service Interdisciplinaire des Systemes Moleculaires et Materiaux, Laboratoire Structure et Dynamique par Resonance Magnetique (LSDRM), CEA Saclay, 91191 Gif sur Yvette (France); Laurette, Julien, E-mail: julien.laurette@cea.fr [UMR3299 CEA-CNRS, Service Interdisciplinaire des Systemes Moleculaires et Materiaux, Laboratoire Structure et Dynamique par Resonance Magnetique (LSDRM), CEA Saclay, 91191 Gif sur Yvette (France); Herlin-Boime, Nathalie, E-mail: nathalie.herlin@cea.fr [URA2453 CEA-CNRS, Service des Photons, Atomes et Molecules, Laboratoire Francis Perrin (LFP), CEA Saclay, 91191 Gif sur Yvette (France); Khodja, Hicham, E-mail: hicham.khodja@cea.fr [UMR3299 CEA-CNRS, Service Interdisciplinaire des Systemes Moleculaires et Materiaux, Laboratoire d' Etude des Elements Legers (LEEL), CEA Saclay, 91191 Gif sur Yvette (France); Fayard, Barbara, E-mail: fayard@lps.u-psud.fr [UMR8502 CNRS-Universite Paris Sud, Laboratoire de Physique des solides (LPS), Universite Paris-Sud, 91405 Orsay (France); European Synchrotron Radiation Facility (ESRF), ID21 beamline, B.P. 220, 38043 Grenoble (France); Flank, Anne-Marie, E-mail: anne-marie.flank@synchrotron-soleil.fr [SOLEIL, Saint Aubin, B.P. 48, 91192 Gif sur Yvette (France); and others

    2012-08-01

    Intensive production of TiO{sub 2} nanoparticles (TiO{sub 2}-NPs) would lead to their release in the environment. Their ecotoxicological impact is still poorly documented, while their use in commercial goods is constantly increasing. In this study we compare root accumulation and root-to-shoot translocation in wheat of anatase and rutile TiO{sub 2}-NPs with diameters ranging from 14 nm to 655 nm, prepared in water. NP distribution in plant tissues was mapped by synchrotron-radiation micro-X-ray fluorescence, observed by transmission electron microscopy and quantified in the different compartments of plant roots by micro-particle-induced X-ray emission. Our results provide evidence that the smallest TiO{sub 2}-NPs accumulate in roots and distribute through whole plant tissues without dissolution or crystal phase modification. We suggest a threshold diameter, 140 nm, above which NPs are no longer accumulated in wheat roots, as well as a threshold diameter, 36 nm, above which NPs are accumulated in wheat root parenchyma but do not reach the stele and consequently do not translocate to the shoot. This accumulation does not impact wheat seed germination, biomass and transpiration. It does not induce any modification of photosynthesis nor induce oxidative stress. However exposure of wheat plantlets to the smallest NPs during the first stages of development causes an increase of root elongation. Collectively, these data suggest that only the smallest TiO{sub 2}-NPs may be accumulated in wheat plants, although in limited amounts and that their impact is moderate. - Highlights: Black-Right-Pointing-Pointer TiO{sub 2}-NP diameter, but not crystallinity, influences their transfer in plant tissues. Black-Right-Pointing-Pointer Wheat roots accumulate TiO{sub 2}-NPs with diameter up to 36 nm but not 140 nm TiO{sub 2}-NPs. Black-Right-Pointing-Pointer TiO{sub 2}-NPs with diameter lower than 36 nm are translocated from wheat root to shoot. Black-Right-Pointing-Pointer A 100 mg

  17. Automatic diameter control system applied to the laser heated pedestal growth technique

    Directory of Open Access Journals (Sweden)

    Andreeta M.R.B.

    2003-01-01

    Full Text Available We described an automatic diameter control system (ADC, for the laser heated pedestal growth technique, that reduces the diameter fluctuations in oxide fibers grown from unreacted and non-sinterized pedestals, to less than 2% of the average fiber diameter, and diminishes the average diameter fluctuation, over the entire length of the fiber, to less than 1%. The ADC apparatus is based on an artificial vision system that controls the pulling speed and the height of the molten zone within a precision of 30 mum. We also show that this system can be used for periodic in situ axial doping the fiber. Pure and Cr3+ doped LaAlO3 and pure LiNbO3 were usedas model materials.

  18. Characteristics of a High Current Helicon Ion Source With High Monatomic Fraction

    International Nuclear Information System (INIS)

    Jung, Hwa-Dong; Chung, Kyoung-Jae; Hwang, Yong-Seok

    2006-01-01

    Applications of neutron need compact and high yield neutron sources as well as very intense neutron sources from giant devices such as accelerators. Ion source based neutron sources using nuclear fusion reactions such as D(d, 3He)n, D(t, 4He)n can meet the requirements. This type of neutron generators can be simply composed of an ion source and a target. High-performance neutron generators with high yield require ion sources with high beam current, high monatomic fraction and long lifetime. Helicon ion source can meet these requirements. To make high current ion source, characteristics of helicon plasma such as high plasma density can be utilized. Moreover, efficient plasma heating with RF power lead high fraction of monatomic ion beam. Here, Characteristics of helicon plasma sources are described. Design and its performances of a helicon ion source are presented

  19. A fractional spline collocation-Galerkin method for the time-fractional diffusion equation

    Directory of Open Access Journals (Sweden)

    Pezza L.

    2018-03-01

    Full Text Available The aim of this paper is to numerically solve a diffusion differential problem having time derivative of fractional order. To this end we propose a collocation-Galerkin method that uses the fractional splines as approximating functions. The main advantage is in that the derivatives of integer and fractional order of the fractional splines can be expressed in a closed form that involves just the generalized finite difference operator. This allows us to construct an accurate and efficient numerical method. Several numerical tests showing the effectiveness of the proposed method are presented.

  20. A generalized fractional sub-equation method for fractional differential equations with variable coefficients

    International Nuclear Information System (INIS)

    Tang, Bo; He, Yinnian; Wei, Leilei; Zhang, Xindong

    2012-01-01

    In this Letter, a generalized fractional sub-equation method is proposed for solving fractional differential equations with variable coefficients. Being concise and straightforward, this method is applied to the space–time fractional Gardner equation with variable coefficients. As a result, many exact solutions are obtained including hyperbolic function solutions, trigonometric function solutions and rational solutions. It is shown that the considered method provides a very effective, convenient and powerful mathematical tool for solving many other fractional differential equations in mathematical physics. -- Highlights: ► Study of fractional differential equations with variable coefficients plays a role in applied physical sciences. ► It is shown that the proposed algorithm is effective for solving fractional differential equations with variable coefficients. ► The obtained solutions may give insight into many considerable physical processes.

  1. Testing the Application of Terrestrial Laser Scanning to Measure Forest Canopy Gap Fraction

    Directory of Open Access Journals (Sweden)

    F. Mark Danson

    2013-06-01

    Full Text Available Terrestrial laser scanners (TLS have the potential to revolutionise measurement of the three-dimensional structure of vegetation canopies for applications in ecology, hydrology and climate change. This potential has been the subject of recent research that has attempted to measure forest biophysical variables from TLS data, and make comparisons with two-dimensional data from hemispherical photography. This research presents a systematic comparison between forest canopy gap fraction estimates derived from TLS measurements and hemispherical photography. The TLS datasets used in the research were obtained between April 2008 and March 2009 at Delamere Forest, Cheshire, UK. The analysis of canopy gap fraction estimates derived from TLS data highlighted the repeatability and consistency of the measurements in comparison with those from coincident hemispherical photographs. The comparison also showed that estimates computed considering only the number of hits and misses registered in the TLS datasets were consistently lower than those estimated from hemispherical photographs. To examine this difference, the potential information available in the intensity values recorded by TLS was investigated and a new method developed to estimate canopy gap fraction proposed. The new approach produced gap fractions closer to those estimated from hemispherical photography, but the research also highlighted the limitations of single return TLS data for this application.

  2. Airstream fractionation of vesicular-arbuscular mycorrhizal fungi: concentration and enumeration of propagules.

    Science.gov (United States)

    Tommerup, I C

    1982-09-01

    Spores and fragments of vesicular-arbuscular mycorrhizal fungi in dry soils were concentrated up to 100-fold when the soils were partitioned by fluidization and elutriation with a series of upward airstreams at progressively increasing velocities. The propagules were transported with the finer soil particles according to their equivalent spherical diameters. The system was used to predict the transport of propagules by wind. Concentrated propagules were rapidly separated from the soil particles in each soil fraction by an aqueous flotation method. The technique is proposed as a quantitative method for estimating the numbers of spores and fragments of mycorrhizae. The scheme includes a viability test that was used to differentiate between potentially infective propagules and those that were either dormant or incapable of regrowth.

  3. Surfactant-nanotube interactions in water and nanotube separation by diameter: atomistic simulations

    Science.gov (United States)

    Carvalho, E. J. F.; Dos Santos, M. C.

    2010-05-01

    A non-destructive sorting method to separate single-walled carbon nanotubes (SWNTs) by diameter was recently proposed. By this method, SWNTs are suspended in water by surfactant encapsulation and the separation is carried out by ultracentrifugation in a density gradient. SWNTs of different diameters are distributed according to their densities along the centrifuge tube. A mixture of two anionic surfactants, namely sodium dodecylsulfate (SDS) and sodium cholate (SC), presented the best performance in discriminating nanotubes by diameter. Unexpectedly, small diameter nanotubes are found at the low density part of the centrifuge tube. We present molecular dynamics studies of the water-surfactant-SWNT system to investigate the role of surfactants in the sorting process. We found that surfactants can actually be attracted towards the interior of the nanotube cage, depending on the relationship between the surfactant radius of gyration and the nanotube diameter. The dynamics at room temperature showed that, as the amphiphile moves to the hollow cage, water molecules are dragged together, thereby promoting the nanotube filling. The resulting densities of filled SWNT are in agreement with measured densities.

  4. Effects of morphology and wavelength on the measurement accuracy of soot volume fraction by laser extinction

    Science.gov (United States)

    Wang, Ya-fei; Huang, Qun-xing; Wang, Fei; Chi, Yong; Yan, Jian-hua

    2018-01-01

    A novel method to evaluate the quantitative effects of soot morphology and incident wavelength on the measurement accuracy of soot volume fraction, by the laser extinction (LE) technique is proposed in this paper. The results indicate that the traditional LE technique would overestimate soot volume fraction if the effects of morphology and wavelength are not considered. Before the agglomeration of isolated soot primary particles, the overestimation of the LE technique is in the range of 2-20%, and rises with increasing primary particle diameter and with decreasing incident wavelength. When isolated primary particles are agglomerated into fractal soot aggregates, the overestimation would exceed 30%, and rise with increasing primary particle number per soot aggregate, fractal dimension and fractal prefactor and with decreasing incident wavelength to a maximum value of 55%. Finally, based on these results above, the existing formula of the LE technique gets modified, and the modification factor is 0.65-0.77.

  5. Asphalt chemical fractionation

    International Nuclear Information System (INIS)

    Obando P, Klever N.

    1998-01-01

    Asphalt fractionation were carried out in the Esmeraldas Oil Refinery using n-pentane, SiO 2 and different mixture of benzene- methane. The fractions obtained were analyzed by Fourier's Transformed Infrared Spectrophotometry (FTIR)

  6. Sex-related differences in the anteroposterior diameter of the foetal cisterna magna

    Energy Technology Data Exchange (ETDEWEB)

    Tao, G. [Department of Ultrasound, Qilu hospital of Shandong University, Jinan (China); Yew, D.T. [Department of Anatomy, Chinese University of Hong Kong (Hong Kong); Gu, T.; Liu, S.; Ma, Z.; Zhan, X.; Cheng, L. [Department of Ultrasound, Qilu hospital of Shandong University, Jinan (China); Li, C. [Department of Ultrasound, Qilu hospital of Shandong University, Jinan (China)], E-mail: chuanfuli2006@hotmail.com

    2008-09-15

    Aim: To measure the anteroposterior diameter of the foetal cisterna magna and observe whether there are differences according to sex. Materials and methods: Three hundred and thirty-seven Chinese women with low-risk pregnancies and a singleton foetus between 22 and 38 weeks' gestational age were included in this retrospective study. Informed consent of the volunteer subjects and hospital authority approval were first obtained. Double-blinded for gender, the anteroposterior diameter of the cisterna magna of the foetuses was measured by transabdominal sonography. Magnetic resonance imaging (MRI) was used for those foetuses with mega cisterna magna. All of the foetuses were healthy by prenatal and postnatal examination, including physical and imaging examination. Results: The mean anteroposterior diameter of the cisterna magna of all foetuses was 8.01 {+-} 1.79 mm. The anteroposterior diameter of the cisterna magna had no obvious correlation with the gestational age. The mean anteroposterior diameter of the cisterna magna of 179 male foetuses was 8.63 {+-} 2.16 mm, and the mean anteroposterior diameter of the cisterna magna of 158 female foetuses was 7.87 {+-} 1.74 mm. The size difference was statistically significant (p < 0.001). In the 33 foetuses with mega cisterna magna, the number of male foetuses was greater than female foetuses, and the proportion of the foetuses with mega cisterna magna in the male group was significantly higher than the foetuses in the female group (p < 0.05). Conclusion: Male foetuses had slightly larger anteroposterior diameters of the cisterna magna than female foetuses. The study would be useful for creating normal range values for the cisterna magna of male and female foetuses.

  7. Stand diameter distribution modelling and prediction based on Richards function.

    Directory of Open Access Journals (Sweden)

    Ai-guo Duan

    Full Text Available The objective of this study was to introduce application of the Richards equation on modelling and prediction of stand diameter distribution. The long-term repeated measurement data sets, consisted of 309 diameter frequency distributions from Chinese fir (Cunninghamia lanceolata plantations in the southern China, were used. Also, 150 stands were used as fitting data, the other 159 stands were used for testing. Nonlinear regression method (NRM or maximum likelihood estimates method (MLEM were applied to estimate the parameters of models, and the parameter prediction method (PPM and parameter recovery method (PRM were used to predict the diameter distributions of unknown stands. Four main conclusions were obtained: (1 R distribution presented a more accurate simulation than three-parametric Weibull function; (2 the parameters p, q and r of R distribution proved to be its scale, location and shape parameters, and have a deep relationship with stand characteristics, which means the parameters of R distribution have good theoretical interpretation; (3 the ordinate of inflection point of R distribution has significant relativity with its skewness and kurtosis, and the fitted main distribution range for the cumulative diameter distribution of Chinese fir plantations was 0.4∼0.6; (4 the goodness-of-fit test showed diameter distributions of unknown stands can be well estimated by applying R distribution based on PRM or the combination of PPM and PRM under the condition that only quadratic mean DBH or plus stand age are known, and the non-rejection rates were near 80%, which are higher than the 72.33% non-rejection rate of three-parametric Weibull function based on the combination of PPM and PRM.

  8. Spontaneous and controlled-diameter synthesis of single-walled and few-walled carbon nanotubes

    Science.gov (United States)

    Inoue, Shuhei; Lojindarat, Supanat; Kawamoto, Takahiro; Matsumura, Yukihiko; Charinpanitkul, Tawatchai

    2018-05-01

    In this study, we explored the spontaneous and controlled-diameter growth of carbon nanotubes. We evaluated the effects of catalyst density, reduction time, and a number of catalyst coating on the substrate (for multi-walled carbon nanotubes) on the diameter of single-walled carbon nanotubes and the number of layers in few-walled carbon nanotubes. Increasing the catalyst density and reduction time increased the diameters of the carbon nanotubes, with the average diameter increasing from 1.05 nm to 1.86 nm for single-walled carbon nanotubes. Finally, we succeeded in synthesizing a significant double-walled carbon nanotube population of 24%.

  9. Height - Diameter predictive equations for Rubber (Hevea ...

    African Journals Online (AJOL)

    BUKOLA

    They proffer logistic data for modeling and futuristic prediction for sustainable forest management. Diameter is one of the most ... in various quantitative estimation following the intricacy of time, availability of modern equipments .... growth functions. This trend is shown in Figure 1 where the prediction equations are plotted.

  10. Density fractions versus size separates: does physical fractionation isolate functional soil compartments?

    Directory of Open Access Journals (Sweden)

    C. Moni

    2012-12-01

    Full Text Available Physical fractionation is a widely used methodology to study soil organic matter (SOM dynamics, but concerns have been raised that the available fractionation methods do not well describe functional SOM pools. In this study we explore whether physical fractionation techniques isolate soil compartments in a meaningful and functionally relevant way for the investigation of litter-derived nitrogen dynamics at the decadal timescale. We do so by performing aggregate density fractionation (ADF and particle size-density fractionation (PSDF on mineral soil samples from two European beech forests a decade after application of 15N labelled litter.

    Both density and size-based fractionation methods suggested that litter-derived nitrogen became increasingly associated with the mineral phase as decomposition progressed, within aggregates and onto mineral surfaces. However, scientists investigating specific aspects of litter-derived nitrogen dynamics are pointed towards ADF when adsorption and aggregation processes are of interest, whereas PSDF is the superior tool to research the fate of particulate organic matter (POM.

    Some methodological caveats were observed mainly for the PSDF procedure, the most important one being that fine fractions isolated after sonication can not be linked to any defined decomposition pathway or protective mechanism. This also implies that historical assumptions about the "adsorbed" state of carbon associated with fine fractions need to be re-evaluated. Finally, this work demonstrates that establishing a comprehensive picture of whole soil OM dynamics requires a combination of both methodologies and we offer a suggestion for an efficient combination of the density and size-based approaches.

  11. Fractional smith chart theory

    KAUST Repository

    Shamim, Atif

    2011-03-01

    For the first time, a generalized Smith chart is introduced here to represent fractional order circuit elements. It is shown that the standard Smith chart is a special case of the generalized fractional order Smith chart. With illustrations drawn for both the conventional integer based lumped elements and the fractional elements, a graphical technique supported by the analytical method is presented to plot impedances on the fractional Smith chart. The concept is then applied towards impedance matching networks, where the fractional approach proves to be much more versatile and results in a single element matching network for a complex load as compared to the two elements in the conventional approach. © 2010 IEEE.

  12. Bark thickness related to tree diameter in sugar maple (Acer saccharum Marsh.)

    Science.gov (United States)

    H. Clay Smith

    1969-01-01

    Bark thickness for sugar maple trees in Vermont was found to be related to tree diameter at breast height (d.b.h.). The relationship was positive-as the diameter increased, the bark thickness increased.

  13. Novel strategy for diameter-selective separation and functionalization of single-wall carbon nanotubes.

    Science.gov (United States)

    Tromp, R M; Afzali, A; Freitag, M; Mitzi, D B; Chen, Zh

    2008-02-01

    The problem of separating single-wall carbon nanotubes (CNTs) by diameter and/or chirality is one of the greatest impediments toward the widespread application of these promising materials in nanoelectronics. In this paper, we describe a novel physical-chemical method for diameter-selective CNT separation that is both simple and effective and that allows up-scaling to large volumes at modest cost. Separation is based on size-selective noncovalent matching of an appropriate anchor molecule to the wall of the CNT, enabling suspension of the CNTs in solvents in which they would otherwise not be soluble. We demonstrate size-selective separation in the 1-2 nm diameter range using easily synthesized oligo-acene adducts as a diameter-selective molecular anchor. CNT field effect transistors fabricated from diameter-selected CNTs show markedly improved electrical properties as compared to nonselected CNTs.

  14. Effect of bubble interface parameters on predicted of bubble departure diameter in a narrow channel

    International Nuclear Information System (INIS)

    Xu Jianjun; Xie Tianzhou; Zhou Wenbin; Chen Bingde; Huang Yanping

    2014-01-01

    The predicted model on the bubble departure diameter in a narrow channel is built by analysis of forces acting on the bubble, and effects of bubble interface parameters such as the bubble inclination angle, upstream contact angle, downstream contact angle and bubble contact diameter on predicted bubble departure diameters in a narrow channel are analysed by comparing with the visual experimental data. Based on the above results, the bubble interface parameters as the input parameters used to obtain the bubble departure diameter in a narrow channel are assured, and the bubble departure diameters in a narrow channel are predicted by solving the force equation. The predicted bubble departure diameters are verified by the 58 bubble departure diameters obtained from the vertical and inclined visual experiment, and the predicted results agree with the experimental results. The different forces acting on the bubble are obtained and the effect of thermal parameters in this experiment on bubble departure diameters is analysed. (authors)

  15. SU-E-J-274: Responses of Medulloblastoma Cells to Radiation Dosimetric Parameters in Intensity-Modulated Radiation Therapy

    International Nuclear Information System (INIS)

    Park, J; Park, J; Rogalla, S; Contag, C; Woo, D; Lee, D; Park, H; Suh, T

    2015-01-01

    Purpose: To evaluate radiation responses of the medulloblastoma cell line Daoy in intensity-modulated radiation therapy (IMRT), quantitative variations to variable radiation dosimetic parameters were tracked by bioluminescent images (BLIs). Methods: The luciferase and green fluorescent protein positive Daoy cells were cultured on dishes. The medulloblastoma cells irradiated to different dose rate, interval of fractionated doses, field margin and misalignment, and dose uniformity in IMRT were monitored using bioluminescent images. The cultured cells were placed into a dedicated acrylic phantom to deliver intensity-modulated fluences and calculate accurate predicted dose distribution. The radiation with dose rate from 0.5 Gy/min to 15 Gy/min was irradiated by adjusting monitor unit per minute and source-to-surface distances. The intervals of fractionated dose delivery were changed considering the repair time of double strand breaks (DSB) revealed by straining of gamma-H2AX.The effect of non-uniform doses on the cells were visualized by registering dose distributions and BLIs. The viability according to dosimetric parameters was correlated with bioluminescent intensities for cross-check of radiation responses. Results: The DSB and cell responses due to the first fractionated dose delivery significantly affected final tumor control rather than other parameters. The missing tumor volumes due to the smaller field margin than the tumor periphery or field misalignment caused relapse of cell responses on BLIs. The dose rate and gradient had effect on initial responses but could not bring out the distinguishable killing effect on cancer cells. Conclusion: Visualized and quantified bioluminescent images were useful to correlate the dose distributions with spatial radiation effects on cells. This would derive the effective combination of dose delivery parameters and fractionation. Radiation responses in particular IMRT configuration could be reflected to image based-dose re-optimization

  16. The Intense Slow Positron Source concept: A theoretical perspective on a proposed INEL Facility

    International Nuclear Information System (INIS)

    Makowitz, H.; Abrashoff, J.D.; Landman, W.H.; Albano, R.K.; Tajima, T.

    1992-01-01

    An analysis has been performed of the INEL Intense Slow Positron Source (ISPS) concept. The results of the theoretical study are encouraging. A full-scale device with a monoenergetic 5 KeV positron beam of ≥10 12 e + /s on a ≤0.03-cmdiameter target appears feasible and can be obtained within the existing infrastructure of INEL reactor facilities. A 30.0-cm-diameter, large area source dish, moderated at first with thin crystalline W films and later by solid Ne, is proposed as the initial device in order to explore problems with a facility scale system. A demonstration scale beam at ≥10 10 slow e + /s is proposed using a 58 Co source plated on a 6-cm-diameter source dish insert, placed in a 30- cm adapter

  17. Hair root diameter measurement as an indicator of protein deficiency in nonhospitalized alcoholics.

    Science.gov (United States)

    Bregar, R R; Gordon, M; Whitney, E N

    1978-02-01

    Protein status of alcoholics admitted to a detoxification center was investigated with a view to adapting a hair root test for use in screening for protein deficiency. Hair root volume and hair root diameter had previously been shown to correlate well with hair root protein and to be sensitive indicators of protein deficiency. Hair root volumes in this study correlated well with mean maximum hair root diameters (n = 35, r = 0.9), which were simpler to measure, so diameter measurements were used. Mean maximum hair root diameters (range 0.02 to 0.19 mm) correlated with plasma RNase concentrations (range 6000 to 14,000 units/ml; n = 17, r = -0.7). Mean hair diameters of 84 alcoholics averaged 0.0864 +/- 0.0366 mm; those of 25 nonalcoholics were significantly greater: 0.100 +/- 0.0254 mm (P less than 0.05). Frequency of occurrence of hair root diameters of 0.06 mm or less was significantly higher in 71 alcoholics (29.5%) than in 23 nonalcoholics (8.6%) matched by age. Mean hair root diameters of 0.06 mm or less therefore can be used to signify protein deficiency where more expensive or technically demanding tests are not feasible. Protein deficiency occurs extensively in non hospitalized alcoholics. This method enables staff to single out those clients most likely to be in need of nutritional counseling and therapy.

  18. Hitungan Diameter Pipa pada Sistem Penyediaan Air Minum sederhana

    Directory of Open Access Journals (Sweden)

    Wahyu Widiyanto

    2010-02-01

    Full Text Available Drinking water sector is one of the public services which is connected tightly to poverty decrease. A small community water supply is more suitable if it uses a simple system which does not need sophisticated planning and construction. Nevertheless, hydraulics calculation should be always conducted accurately because it will influence water supply performance. In this case, pipe hydraulics needs more overview because system reliability depends on pipe capacity. This study discusses two methods of pipe diameter calculation at a simple drinking water supply system. For planning assistance, Directorate General Cipta Karya-Public Work Ministry issued Technical Guideline Book for Simple Drinking Water Construction in 2007. One of its chapters discusses about a method to find pipe diameter based on several tables available, but it is not given an explanation about basic theory of the tables so there is a doubt for planners. For the reason, comparison between the use of the tables (Juknis Method and Darcy-Weisbach Formula to calculate pipe diameter will be discussed. Data from 5 villages in Kebumen Regency will be utilized to support analysis. The result of procedure for making comparison shows that there is no significant difference (less than 4% between the result of calculation by Darcy-Weisbach Formula and Juknis Method with accurate interpolation. Both of the methods can be applied with its advantages and disadvantages. It is suggested that Darcy-Weisbach Formula is always implemented to re-check toward pipe diameter which is available in the market and will be used in the system.

  19. 78 FR 60897 - Certain Welded Large Diameter Line Pipe From Japan

    Science.gov (United States)

    2013-10-02

    ... Diameter Line Pipe From Japan Determination On the basis of the record \\1\\ developed in the subject five... order on certain welded large diameter line pipe from Japan would likely to lead to continuation or... Line Pipe from Japan: Investigation No. 731-TA-919 (Second Review). By order of the Commission. Issued...

  20. In vivo and ex vivo characterization of a novel Er fiber laser system for fractional treatment of soft oral tissues

    Science.gov (United States)

    Shatilova, Ksenia; Aloian, Georgii; Karabut, Maria; Ryabova, Valentina; Yaroslavsky, Ilya V.; Altshuler, Gregory

    2018-02-01

    In this work, we present the first histological in vivo and ex vivo study of effects of fractional Er fiber laser (wavelength 1550 nm, peak power 25 W) on keratinized gum and alveolar mucosa for gum regeneration. Biopsy with subsequent NBTC staining was used as primary evaluation technique. Ex vivo, porcine tissue model was used. Effects of pulse energy, beam diameter, and beam divergence were investigated in detail. It has been demonstrated that under optimal conditions columns up to 800 μm in depth could be reliably produced with 130 mJ pulses. Clinically, 2 subjects were treated and 4 punch biopsies were collected. The results were compared with ex vivo data. Both ex vivo and in vivo datasets suggest feasibility of a dental fractional system intended for gum regeneration.