  1. 75 FR 14496 - Commerce Acquisition Regulation (CAR); Correction

    Science.gov (United States)

    2010-03-26

    ... DEPARTMENT OF COMMERCE 48 CFR Part 1352 [Document Number: 080730954-0129-03] RIN 0605-AA26 Commerce Acquisition Regulation (CAR); Correction AGENCY: Department of Commerce (DOC). ACTION: Final rule; correction. SUMMARY: We, the Department of Commerce, issue a final rule to bring the Commerce Acquisition...

  2. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    International Nuclear Information System (INIS)

    Law, M; Yuan, J; Wong, O; Yu, S

    2016-01-01

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck

  3. SU-G-IeP1-08: MR Geometric Distortion Dependency On Imaging Sequence, Acquisition Orientation and Receiver Bandwidth of a Dedicated 1.5T MR-Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Law, M; Yuan, J; Wong, O; Yu, S [Hong Kong Sanatorium & Hospital, Hong Kong, Hong Kong (Hong Kong)

    2016-06-15

    Purpose: To investigate the 3D geometric distortion of four potential MR sequences for radiotheraptic applications, and its dependency on sequence-type, acquisition-orientation and receiver-bandwidth from a dedicated 1.5T 700mm-wide bore MR-simulator (Magnetom-Aera, Sienmens Healthcare, Erlangen, Germany), using a large customized geometric accuracy phantom. Methods: This work studied 3D gradient-echo (VIBE) and spin-echo (SPACE) sequences for anatomical imaging; a specific ultra-short-TE sequence (PETRA) potentially for bone imaging and MR-based dosimetry; and a motion-insensitive sequence (BLADE) for dynamic applications like 4D-MRI. Integrated geometric-correction was employed, three orthogonal acquisition-orientations and up to three receiver-bandwidths were used, yielding 27 acquisitions for testing (Table 1a).A customized geometric accuracy phantom (polyurethane, MR/CT invisible, W×L×H:55×55×32.5cm3) was constructed and filled with 3892 spherical markers (6mm diameter, MR/CT visible) arranged on a 25mm-interval 3D isotropic-grid (Fig.1). The marker positions in MR images were quantitatively calculated and compared against those in the CT-reference using customized MatLab scripts. Results: The average distortion within various diameter-of-spherical-volumes (DSVs) and the usable DSVs under various distortion limits were measured (Tables 1b-c). It was observed that distortions fluctuated when sequence-type, acquisition-orientation or receiver-bandwidth changed (e.g. within 300mm-DSV, the lowest/highest average distortions of VIBE were 0.40mm/0.59mm, a 47.5% difference). According to AAPM-TG66 (<1mm distortion, left-most column of Table 1c), PETRA (Largest-DSV:253.9mm) has the potential on brain treatment, while BLADE (Largest-DSV:207.2mm) may need improvement for thoracic/abdominal applications. The results of VIBE (Largest-DSVs:294.3mm, the best among tested acquisitions) and SPACE (Largest-DSVs:267.7mm) suggests their potentials on head and neck

  4. Simultaneous PET-MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET

    International Nuclear Information System (INIS)

    Tsoumpas, C.; Mackewn, J.E.; Halsted, P.; King, A.P.; Buerger, C.; Totman, J.J.; Schaeffter, T.; Marsden, P.K.

    2010-01-01

    Positron emission tomography (PET) provides an accurate measurement of radiotracer concentration in vivo, but performance can be limited by subject motion which degrades spatial resolution and quantitative accuracy. This effect may become a limiting factor for PET studies in the body as PET scanner technology improves. In this work, we propose a new approach to address this problem by employing motion information from images measured simultaneously using a magnetic resonance (MR) scanner. The approach is demonstrated using an MR-compatible PET scanner and PET-MR acquisition with a purpose-designed phantom capable of non-rigid deformations. Measured, simultaneously acquired MR data were used to correct for motion in PET, and results were compared with those obtained using motion information from PET images alone. Motion artefacts were significantly reduced and the PET image quality and quantification was significantly improved by the use of MR motion fields, whilst the use of PET-only motion information was less successful. Combined PET-MR acquisitions potentially allow PET motion compensation in whole-body acquisitions without prolonging PET acquisition time or increasing radiation dose. This, to the best of our knowledge, is the first study to demonstrate that simultaneously acquired MR data can be used to estimate and correct for the effects of non-rigid motion in PET. (author)

  5. Rosen's (M,R) system in process algebra.

    Science.gov (United States)

    Gatherer, Derek; Galpin, Vashti

    2013-11-17

    Robert Rosen's Metabolism-Replacement, or (M,R), system can be represented as a compact network structure with a single source and three products derived from that source in three consecutive reactions. (M,R) has been claimed to be non-reducible to its components and algorithmically non-computable, in the sense of not being evaluable as a function by a Turing machine. If (M,R)-like structures are present in real biological networks, this suggests that many biological networks will be non-computable, with implications for those branches of systems biology that rely on in silico modelling for predictive purposes. We instantiate (M,R) using the process algebra Bio-PEPA, and discuss the extent to which our model represents a true realization of (M,R). We observe that under some starting conditions and parameter values, stable states can be achieved. Although formal demonstration of algorithmic computability remains elusive for (M,R), we discuss the extent to which our Bio-PEPA representation of (M,R) allows us to sidestep Rosen's fundamental objections to computational systems biology. We argue that the behaviour of (M,R) in Bio-PEPA shows life-like properties.

  6. CTD data from R/V Kilo Moana Cruise KM1123 during 2011-08 north of Hawaii (NODC Accession 0125443)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Profiles were taken with a Sea-Bird SBE-911 plus CTD from the R/V Kilo Moana on cruise KM1123 2011-08-11 to 2011-08-25 in the vicinity of Station ALOHA, the Hawaii...

  7. Rosen's (M,R) system in Unified Modelling Language.

    Science.gov (United States)

    Zhang, Ling; Williams, Richard A; Gatherer, Derek

    2016-01-01

    Robert Rosen's (M,R) system is an abstract biological network architecture that is allegedly non-computable on a Turing machine. If (M,R) is truly non-computable, there are serious implications for the modelling of large biological networks in computer software. A body of work has now accumulated addressing Rosen's claim concerning (M,R) by attempting to instantiate it in various software systems. However, a conclusive refutation has remained elusive, principally since none of the attempts to date have unambiguously avoided the critique that they have altered the properties of (M,R) in the coding process, producing merely approximate simulations of (M,R) rather than true computational models. In this paper, we use the Unified Modelling Language (UML), a diagrammatic notation standard, to express (M,R) as a system of objects having attributes, functions and relations. We believe that this instantiates (M,R) in such a way than none of the original properties of the system are corrupted in the process. Crucially, we demonstrate that (M,R) as classically represented in the relational biology literature is implicitly a UML communication diagram. Furthermore, since UML is formally compatible with object-oriented computing languages, instantiation of (M,R) in UML strongly implies its computability in object-oriented coding languages. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. 48 CFR 1352.301 - Solicitation provisions and contract clauses (Matrix).

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Solicitation provisions and contract clauses (Matrix). 1352.301 Section 1352.301 Federal Acquisition Regulations System... Matrix 1352.301 Solicitation provisions and contract clauses (Matrix). ER08MR10.000 ER08MR10.001 ER08MR10...

  9. Generalisation for regular black holes on general relativity to f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Manuel E. [Universidade Federal do Para Campus Universitario de Abaetetuba, Faculdade de Ciencias Exatas e Tecnologia, Abaetetuba, Para (Brazil); Universidade Federal do Para, Faculdade de Fisica, PPGF, Belem, Para (Brazil); Fabris, Julio C. [Universidade Federal do Espirito Santo, Vitoria, ES (Brazil); National Research Nuclear University MEPhI, Moscow (Russian Federation); Junior, Ednaldo L.B. [Universidade Federal do Para, Faculdade de Fisica, PPGF, Belem, Para (Brazil); Universidade Federal do Para, Campus Universitario de Tucurui, Faculdade de Engenharia da Computacao, Tucurui, Para (Brazil); Marques, Glauber T. [Universidade Federal Rural da Amazonia ICIBE - LASIC, Belem, PA (Brazil)

    2016-05-15

    IIn this paper, we determine regular black hole solutions using a very general f(R) theory, coupled to a nonlinear electromagnetic field given by a Lagrangian L{sub NED}. The functions f(R) and L{sub NED} are in principle left unspecified. Instead, the model is constructed through a choice of the mass function M(r) presented in the metric coefficients. Solutions which have a regular behaviour of the geometric invariants are found. These solutions have two horizons, the event horizon and the Cauchy horizon. All energy conditions are satisfied in the whole space-time, except the strong energy condition (SEC), which is violated near the Cauchy horizon.We present also a new theorem related to the energy conditions in f(R) gravity, re-obtaining the well-known conditions in the context of general relativity when the geometry of the solution is the same. (orig.)

  10. Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

    Science.gov (United States)

    Catana, Ciprian; Wu, Yibao; Judenhofer, Martin S; Qi, Jinyi; Pichler, Bernd J; Cherry, Simon R

    2006-12-01

    PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode (PSAPD) detectors coupled, via short lengths of optical fibers, to arrays of lutetium oxyorthosilicate (LSO) scintillator crystals. The optical fibers are used to minimize electromagnetic interference between the radiofrequency and gradient coils and the PET detector system. The PET detector module components and the complete PET insert assembly are described. PET data were acquired with and without MR sequences running, and detector flood histograms were compared with the ones generated from the data acquired outside the magnet. A uniform MR phantom was also imaged to assess the effect of the PET detector on the MR data acquisition. Simultaneous PET and MRI studies of a mouse were performed ex vivo. PSAPDs can be successfully used to read out large numbers of scintillator crystals coupled through optical fibers with acceptable performance in terms of energy and timing resolution and crystal identification. The PSAPD-LSO detector performs well in the 7-T magnet, and no visible artifacts are detected in the MR images using standard pulse sequences. The first images from the complete system have been successfully acquired and reconstructed, demonstrating that simultaneous PET and MRI studies are feasible and opening up interesting possibilities for dual-modality molecular imaging studies.

  11. MR cholangiopancreatography. Comparison of images obtained with 1.0 and 1.5 tesla units

    International Nuclear Information System (INIS)

    Yasui, Masayasu; Ito, Katsuyoshi; Koike, Shinji; Matsunaga, Naofumi

    2002-01-01

    The purpose of this study was to compare the image quality and visualization obtained in MR cholangiopancreatography (MRCP) using different high-field strength (1.0 vs. 1.5 Tesla) MR units and to assess the effect of field strength on MRCP. This study population included 10 healthy volunteers and 37 patients suspected of having pancreatobiliary diseases. MRCP images were obtained using two MR units with different high-field strengths (1.0 and 1.5 Tesla), with half-Fourier acquisition single-shot turbo spin-echo (HASTE) and rapid acquisition by relaxation enhancement (RARE) sequences. The image quality and visualization of each portion of the pancreatobiliary system were graded and recorded using a four-point scale. Additionally, the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured. The SNR and CNR in HASTE sequences acquired with the 1.5 Tesla (T) unit were significantly higher than those acquired with the 1.0 T unit (p=0.001). In qualitative analysis, there were no statistically significant differences in image quality or visualization of the ducts in either HASTE or RARE sequences between 1.0 T and 1.5 T. Our study showed that visual image quality provided by MRCP was equivalent at 1.0 and 1.5 T. (author)

  12. 15 CFR 16.10 - The Department of Commerce Mark.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false The Department of Commerce Mark. 16.10 Section 16.10 Commerce and Foreign Trade Office of the Secretary of Commerce PROCEDURES FOR A VOLUNTARY CONSUMER PRODUCT INFORMATION LABELING PROGRAM § 16.10 The Department of Commerce Mark. The Department of...

  13. TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

    International Nuclear Information System (INIS)

    Lee, H; Alqathami, M; Wang, J; Ibbott, G; Kadbi, M; Blencowe, A

    2016-01-01

    Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe 3+ ) reduction versus ferrous ion (Fe 2+ ) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T 1 -weighted and inversion recovery sequences). Results: Irradiation of Fe 3+ reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R 2 =1.00). T 1 -weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe 2+ oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T 1 -weighted-MR SI, and R 1 relative to dose exhibited a linear response up to at least 8 Gy (R 2 =1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T 1 -weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R 2 >0.93). Conclusion: The Fe 2+ oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose readout. The Fe 3+ reduction system is recommended for high

  14. TH-CD-BRA-08: Novel Iron-Based Radiation Reporting Systems as 4D Dosimeters for MR-Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, H; Alqathami, M; Wang, J; Ibbott, G [UT MD Anderson Cancer Center, Houston, TX (United States); Kadbi, M [MR Therapy, Philips healthTech, Cleveland, OH (United States); Blencowe, A [The University of South Australia, South Australia, SA (Australia)

    2016-06-15

    Purpose: To compare novel radiation reporting systems utilizing ferric ion (Fe{sup 3+}) reduction versus ferrous ion (Fe{sup 2+}) oxidation in gelatin matrixes for 3D and 4D (3D+time) MR-guided radiation therapy dosimetry. Methods: Dosimeters were irradiated using an integrated 1.5T MRI and 7MV linear accelerator (MR-Linac). Dosimeters were read-out with both a spectrophotometer and the MRI component of the MR-Linac immediately after irradiation. Changes in optical density (OD) were measured using a spectrophotometer; changes in MR signal intensity due to the paramagnetic differences in the iron ions were measured using the MR-Linac in real-time during irradiation (balanced-FFE sequences) and immediately after irradiation (T{sub 1}-weighted and inversion recovery sequences). Results: Irradiation of Fe{sup 3+} reduction dosimeters resulted in a stable red color with an absorbance peak at 512 nm. The change in OD relative to dose exhibited a linear response up to 100 Gy (R{sup 2}=1.00). T{sub 1}-weighted-MR signal intensity (SI) changed minimally after irradiation with increases of 8.0% for 17 Gy and 9.7% after escalation to 35 Gy compared to the un-irradiated region. Irradiation of Fe{sup 2+} oxidation dosimeters resulted in a stable purple color with absorbance peaks at 440 and 585 nm. The changes in OD, T{sub 1}-weighted-MR SI, and R{sub 1} relative to dose exhibited a linear response up to at least 8 Gy (R{sup 2}=1.00, 0.98, and 0.99) with OD saturation above 40 Gy. The T{sub 1}-weighted-MR SI increased 50.3% for 17 Gy compared to the un-irradiated region. The change in SI was observed in both 2D+time and 4D (3D+time) acquisitions post-irradiation and in real-time during irradiation with a linear increase with respect to dose (R{sup 2}>0.93). Conclusion: The Fe{sup 2+} oxidation-based system was superior as 4D dosimeters for MR-guided radiation therapy due to its higher sensitivity in both optical and MR signal readout and feasibility for real-time 4D dose

  15. 75 FR 10567 - Commerce Acquisition Regulation (CAR)

    Science.gov (United States)

    2010-03-08

    ... regulations, Federal acquisition regulations, Government procurement, Government contracts, Procurement, Reporting and recordkeeping requirements. 48 CFR Part 1302 Definitions, Government procurement, Terms. 48 CFR Part 1303 Antitrust, Conflict of interests, Ethical conduct, Government procurement, Reporting and...

  16. Fast generation of 4D PET-MR data from real dynamic MR acquisitions

    International Nuclear Information System (INIS)

    Tsoumpas, C; Buerger, C; King, A P; Schleyer, P; Schaeffter, T; Marsden, P K; Mollet, P; Keereman, V; Vandenberghe, S; Schulz, V

    2011-01-01

    We have implemented and evaluated a framework for simulating simultaneous dynamic PET-MR data using the anatomic and dynamic information from real MR acquisitions. PET radiotracer distribution is simulated by assigning typical FDG uptake values to segmented MR images with manually inserted additional virtual lesions. PET projection data and images are simulated using analytic forward projections (including attenuation and Poisson statistics) implemented within the image reconstruction package STIR. PET image reconstructions are also performed with STIR. The simulation is validated with numerical simulation based on Monte Carlo (GATE) which uses more accurate physical modelling, but has 150x slower computation time compared to the analytic method for ten respiratory positions and is 7000x slower when performing multiple realizations. Results are validated in terms of region of interest mean values and coefficients of variation for 65 million coincidences including scattered events. Although some discrepancy is observed, agreement between the two different simulation methods is good given the statistical noise in the data. In particular, the percentage difference of the mean values is 3.1% for tissue, 17% for the lungs and 18% for a small lesion. The utility of the procedure is demonstrated by simulating realistic PET-MR datasets from multiple volunteers with different breathing patterns. The usefulness of the toolkit will be shown for performance investigations of the reconstruction, motion correction and attenuation correction algorithms for dynamic PET-MR data.

  17. 78 FR 31551 - Federal Acquisition Regulation; Submission for OMB Review; Commerce Patent Regulations

    Science.gov (United States)

    2013-05-24

    ...; Submission for OMB Review; Commerce Patent Regulations AGENCIES: Department of Defense (DOD), General... collection requirement concerning Department of Commerce patent regulations. A notice was published in...- 0095, Commerce Patent Regulations, by any of the following methods: Regulations.gov : http://www...

  18. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the OCEAN VERITAS in the Gulf of Mexico from 2010-08-06 to 2010-08-10 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069103)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the OCEAN VERITAS in the Gulf of Mexico from 2010-08-06 to 2010-08-10 in...

  19. A viable logarithmic f(R) model for inflation

    Energy Technology Data Exchange (ETDEWEB)

    Amin, M.; Khalil, S. [Center for Fundamental Physics, Zewail City of Science and Technology,6 October City, Giza (Egypt); Salah, M. [Center for Fundamental Physics, Zewail City of Science and Technology,6 October City, Giza (Egypt); Department of Mathematics, Faculty of Science, Cairo University,Giza (Egypt)

    2016-08-18

    Inflation in the framework of f(R) modified gravity is revisited. We study the conditions that f(R) should satisfy in order to lead to a viable inflationary model in the original form and in the Einstein frame. Based on these criteria we propose a new logarithmic model as a potential candidate for f(R) theories aiming to describe inflation consistent with observations from Planck satellite (2015). The model predicts scalar spectral index 0.9615r of order 10{sup −3}. Furthermore, we show that for a class of models, a natural coupling between inflation and a scalar boson is generated through the minimal coupling between gravity and matter fields and a reheating temperature less that 10{sup 9} GeV is obtained.

  20. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    International Nuclear Information System (INIS)

    Huang, Chuan; Petibon, Yoann; Ouyang, Jinsong; El Fakhri, Georges; Reese, Timothy G.; Ahlman, Mark A.; Bluemke, David A.

    2015-01-01

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  1. Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: Phantom and patient studies

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chuan, E-mail: chuan.huang@stonybrookmedicine.edu [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Departments of Radiology, Psychiatry, Stony Brook Medicine, Stony Brook, New York 11794 (United States); Petibon, Yoann [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States); Ouyang, Jinsong; El Fakhri, Georges [Center for Advanced Medical Imaging Sciences, Division of Nuclear Medicine and Molecular Imaging, Department of Imaging, Massachusetts General Hospital, Boston, Massachusetts 02114 and Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 (United States); Reese, Timothy G. [Department of Radiology, Harvard Medical School, Boston, Massachusetts 02115 and Martinos Center for Biomedical Imaging, Charlestown, Massachusetts 02129 (United States); Ahlman, Mark A.; Bluemke, David A. [Radiology and Imaging Sciences, National Institutes of Health Clinical Center, Bethesda, Maryland 20892 (United States)

    2015-02-15

    Purpose: Degradation of image quality caused by cardiac and respiratory motions hampers the diagnostic quality of cardiac PET. It has been shown that improved diagnostic accuracy of myocardial defect can be achieved by tagged MR (tMR) based PET motion correction using simultaneous PET-MR. However, one major hurdle for the adoption of tMR-based PET motion correction in the PET-MR routine is the long acquisition time needed for the collection of fully sampled tMR data. In this work, the authors propose an accelerated tMR acquisition strategy using parallel imaging and/or compressed sensing and assess the impact on the tMR-based motion corrected PET using phantom and patient data. Methods: Fully sampled tMR data were acquired simultaneously with PET list-mode data on two simultaneous PET-MR scanners for a cardiac phantom and a patient. Parallel imaging and compressed sensing were retrospectively performed by GRAPPA and kt-FOCUSS algorithms with various acceleration factors. Motion fields were estimated using nonrigid B-spline image registration from both the accelerated and fully sampled tMR images. The motion fields were incorporated into a motion corrected ordered subset expectation maximization reconstruction algorithm with motion-dependent attenuation correction. Results: Although tMR acceleration introduced image artifacts into the tMR images for both phantom and patient data, motion corrected PET images yielded similar image quality as those obtained using the fully sampled tMR images for low to moderate acceleration factors (<4). Quantitative analysis of myocardial defect contrast over ten independent noise realizations showed similar results. It was further observed that although the image quality of the motion corrected PET images deteriorates for high acceleration factors, the images were still superior to the images reconstructed without motion correction. Conclusions: Accelerated tMR images obtained with more than 4 times acceleration can still provide

  2. 78 FR 18349 - Federal Acquisition Regulation; Information Collection; Commercial Item Acquisitions

    Science.gov (United States)

    2013-03-26

    ... information provided. FOR FURTHER INFORMATION CONTACT: Mr. Michael O. Jackson, Procurement Analyst, Office of Governmentwide Acquisition Policy, GSA (202) 208- 4949 or email at michaelo.jackson@gsa.gov . SUPPLEMENTARY...

  3. Evaluation of left ventricular mass in vitro and in vivo with MR imaging

    International Nuclear Information System (INIS)

    Mogelvang, J.; Thomsen, C.; Mehisen, J.; Henriksen, O.; Horn, T.

    1986-01-01

    The left ventricular (LV) mass was determined by MR multisection imaging in ten unopened postmortem human hearts and compared with the true weight of the isolated LV. In addition, the LV mass in 14 patients was determined by MR imaging. LV myocardial volume determined from acquisitions at end diastole were compared with the volume determined from acquisitions at end systole. The LV masses as determined on MR imaging showed excellent correlation with reference values (r = .99, P < .001). There was fine correlation between myocardial volume (mass) estimated in vivo in diastole and systole (r = .95, P < .0001). These results suggest that MR imaging is accurate for the determination of LV mass in vivo

  4. Automated brain tissue and myelin volumetry based on quantitative MR imaging with various in-plane resolutions.

    Science.gov (United States)

    Andica, C; Hagiwara, A; Hori, M; Nakazawa, M; Goto, M; Koshino, S; Kamagata, K; Kumamaru, K K; Aoki, S

    2018-05-01

    Segmented brain tissue and myelin volumes can now be automatically calculated using dedicated software (SyMRI), which is based on quantification of R 1 and R 2 relaxation rates and proton density. The aim of this study was to determine the validity of SyMRI brain tissue and myelin volumetry using various in-plane resolutions. We scanned 10 healthy subjects on a 1.5T MR scanner with in-plane resolutions of 0.8, 2.0 and 3.0mm. Two scans were performed for each resolution. The acquisition time was 7-min and 24-sec for 0.8mm, 3-min and 9-sec for 2.0mm and 1-min and 56-sec for 3.0mm resolutions. The volumes of white matter (WM), gray matter (GM), cerebrospinal fluid (CSF), non-WM/GM/CSF (NoN), brain parenchymal volume (BPV), intracranial volume (ICV) and myelin were compared between in-plane resolutions. Repeatability for each resolution was then analyzed. No significant differences in volumes measured were found between the different in-plane resolutions, except for NoN between 0.8mm and 2.0mm and between 2.0mm and 3.0mm. The repeatability error value for the WM, GM, CSF, NoN, BPV and myelin volumes relative to ICV was 0.97%, 1.01%, 0.65%, 0.86%, 1.06% and 0.25% in 0.8mm; 1.22%, 1.36%, 0.73%, 0.37%, 1.18% and 0.35% in 2.0mm and 1.18%, 1.02%, 0.96%, 0.45%, 1.36%, and 0.28% in 3.0mm resolutions. SyMRI brain tissue and myelin volumetry with low in-plane resolution and short acquisition times is robust and has a good repeatability so could be useful for follow-up studies. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. 37 CFR 10.64 - Avoiding acquisition of interest in litigation or proceeding before the Office.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Avoiding acquisition of interest in litigation or proceeding before the Office. 10.64 Section 10.64 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE REPRESENTATION OF OTHERS BEFORE THE PATENT AND TRADEMARK OFFICE Patent and...

  6. Future dynamics in f(R) theories

    International Nuclear Information System (INIS)

    Mueller, D.; Andrade, V.C. de; Maia, C.; Reboucas, M.J.; Teixeira, A.F.F.

    2015-01-01

    The f(R) gravity theories provide an alternative way to explain the current cosmic acceleration without invoking a dark energy matter component used in the cosmological modeling in the framework of general relativity. However, the freedom in the choice of the functional forms of f(R) gives rise to the problem of the degeneracy among these gravity theories on theoretical and (or) observational grounds. In this paper we examine the question as to whether the future dynamics can be used to break the degeneracy between f(R) gravity theories by investigating the dynamics of spatially homogeneous and isotropic dust flat models in two f(R) gravity theories, namely the well known f(R) = R+αR n gravity and another byAviles et al., whose motivation comes from the cosmographic approach to f(R) gravity. We perform a detailed numerical study of the dynamics of these theories taking into account the recent constraints on the cosmological parameters made by the Planck Collaboration. We demonstrate that besides being useful for discriminating between these two f(R) gravity theories, the future dynamics technique can also be used to determine the finite-time behavior as well as the fate of the Universe in the framework of these f(R) gravity theories. There also emerges from our analysis the result that one still can have a dust flat FLRWsolution with a big rip, if gravity is governed by f(R) = R+αR n . We also show that FLRW dust solutions with f'' < 0 do not necessarily lead to singularities. (orig.)

  7. Technological Similarity, Post-acquisition R&D Reorganization, and Innovation Performance in Horizontal Acquisition

    DEFF Research Database (Denmark)

    Colombo, Massimo G.; Rabbiosi, Larissa

    2014-01-01

    This paper aims to disentangle the mechanisms through which technological similarity between acquiring and acquired firms influences innovation in horizontal acquisitions. We develop a theoretical model that links technological similarity to: (i) two key aspects of post-acquisition reorganization...... of acquired R&D operations – the rationalization of the R&D operations and the replacement of the R&D top manager, and (ii) two intermediate effects that are closely associated with the post-acquisition innovation performance of the combined firm – improvements in R&D productivity and disruptions in R......&D personnel. We rely on PLS techniques to test our theoretical model using detailed information on 31 horizontal acquisitions in high- and medium-tech industries. Our results indicate that in horizontal acquisitions, technological similarity negatively affects post-acquisition innovation performance...

  8. 78 FR 45168 - Acquisition Regulations: Export Control

    Science.gov (United States)

    2013-07-26

    ... DEPARTMENT OF ENERGY 48 CFR Parts 925, 952 and 970 RIN 1991-AB99 Acquisition Regulations: Export... (78 FR 35195) to amend the Department of Energy Acquisition Regulation (DEAR) to add export control... ``DEAR: Export Control and RIN 1991-AB99,'' by any of the following methods: Federal eRulemaking Portal...

  9. 78 FR 53761 - Federal Acquisition Regulation; Submission for OMB Review; Commercial Item Acquisitions

    Science.gov (United States)

    2013-08-30

    ... provided. FOR FURTHER INFORMATION CONTACT: Mr. Michael O. Jackson, Procurement Analyst, Office of Governmentwide Acquisition Policy, GSA (202) 208- 4949 or email at michaelo.jackson@gsa.gov . SUPPLEMENTARY...

  10. Foreign acquisitions, domestic multinationals, and R&D

    DEFF Research Database (Denmark)

    Bandick, Roger; Görg, Holger; Karpaty, Patrik

    endogeneity of the acquisition dummy.  Overall, our results give no support to the fears that foreign acquisition of domestic firms lead to a brain drain of R&D activity in Swedish MNEs. Rather, this paper finds robust evidence that foreign acquisitions lead to increasing R&D intensity in acquired domestic......The aim of this paper is to evaluate the causal effect of foreign acquisition on R&D intensity in targeted domestic firms. We are able to distinguish domestic multinationals and non-multinationals, which allows us to investigate the fear that the change in ownership of domestic to foreign...

  11. SU-F-R-32: Evaluation of MRI Acquisition Parameter Variations On Texture Feature Extraction Using ACR Phantom

    International Nuclear Information System (INIS)

    Xie, Y; Wang, J; Wang, C; Chang, Z

    2016-01-01

    Purpose: To investigate the sensitivity of classic texture features to variations of MRI acquisition parameters. Methods: This study was performed on American College of Radiology (ACR) MRI Accreditation Program Phantom. MR imaging was acquired on a GE 750 3T scanner with XRM explain gradient, employing a T1-weighted images (TR/TE=500/20ms) with the following parameters as the reference standard: number of signal average (NEX) = 1, matrix size = 256×256, flip angle = 90°, slice thickness = 5mm. The effect of the acquisition parameters on texture features with and without non-uniformity correction were investigated respectively, while all the other parameters were kept as reference standard. Protocol parameters were set as follows: (a). NEX = 0.5, 2 and 4; (b).Phase encoding steps = 128, 160 and 192; (c). Matrix size = 128×128, 192×192 and 512×512. 32 classic texture features were generated using the classic gray level run length matrix (GLRLM) and gray level co-occurrence matrix (GLCOM) from each image data set. Normalized range ((maximum-minimum)/mean) was calculated to determine variation among the scans with different protocol parameters. Results: For different NEX, 31 out of 32 texture features’ range are within 10%. For different phase encoding steps, 31 out of 32 texture features’ range are within 10%. For different acquisition matrix size without non-uniformity correction, 14 out of 32 texture features’ range are within 10%; for different acquisition matrix size with non-uniformity correction, 16 out of 32 texture features’ range are within 10%. Conclusion: Initial results indicated that those texture features that range within 10% are less sensitive to variations in T1-weighted MRI acquisition parameters. This might suggest that certain texture features might be more reliable to be used as potential biomarkers in MR quantitative image analysis.

  12. Dynamic 3D MR-defecography

    Energy Technology Data Exchange (ETDEWEB)

    Ratz, V.; Wech, T.; Schindele, A.; Dierks, A.; Sauer, A.; Reibetanz, J.; Borzi, A.; Bley, T.; Koestler, H.

    2016-09-15

    Epidemiological studies have estimated the incidence of chronic constipation to be up to 27% of the general population. The gold standard to evaluate affected patients is the dynamic entero-colpo-cysto-defecography. In the clinical routine 2 D MR-defecography is also performed, but only one to three 2 D slices at a temporal footprint of about one second are acquired. To improve the detection of lateral localized pathologies, we developed and implemented dynamic 3 D MR-defecography. Each 3 D block consisted of seven slices with an in-plane spatial resolution of 1.3 x 1.3 mm{sup 2} to 2.3 x 2.3 mm{sup 2} and an image update rate between 0.8 s and 1.3 s. We used a fast bSSFP sequence with a modified stack-of-stars sampling scheme for data acquisition and a modified FISTA compressed sensing algorithm to reconstruct the undersampled datasets. We performed a study including 6 patients to optimize the acquisition parameters with respect to image quality.

  13. Dynamic 3D MR-defecography

    International Nuclear Information System (INIS)

    Ratz, V.; Wech, T.; Schindele, A.; Dierks, A.; Sauer, A.; Reibetanz, J.; Borzi, A.; Bley, T.; Koestler, H.

    2016-01-01

    Epidemiological studies have estimated the incidence of chronic constipation to be up to 27% of the general population. The gold standard to evaluate affected patients is the dynamic entero-colpo-cysto-defecography. In the clinical routine 2 D MR-defecography is also performed, but only one to three 2 D slices at a temporal footprint of about one second are acquired. To improve the detection of lateral localized pathologies, we developed and implemented dynamic 3 D MR-defecography. Each 3 D block consisted of seven slices with an in-plane spatial resolution of 1.3 x 1.3 mm 2 to 2.3 x 2.3 mm 2 and an image update rate between 0.8 s and 1.3 s. We used a fast bSSFP sequence with a modified stack-of-stars sampling scheme for data acquisition and a modified FISTA compressed sensing algorithm to reconstruct the undersampled datasets. We performed a study including 6 patients to optimize the acquisition parameters with respect to image quality.

  14. Foreign acquisitions, domestic multinationals, and R&D

    DEFF Research Database (Denmark)

    Bandick, Roger; Görg, Holger; Karpaty, Patrik

    2014-01-01

    The aim of this paper is to evaluate the causal effect of foreign acquisition on R&D intensity in targeted domestic firms. We are able to distinguish domestic multinationals and non-multinationals, which allows us to investigate the fear that the change in ownership of domestic to foreign...... multinationals leads to a reduction in R&D activity in the country. We use unique and rich firm level data for the Swedish manufacturing sector and micro-econometric estimation strategies in order to control for the potential endogeneity of the acquisition decision. Overall, our results give no support...... to the fears that foreign acquisition of domestic firms lead to a relocation of R&D activity in Swedish MNEs. Rather, this paper finds robust evidence that foreign acquisitions lead to increasing R&D intensity in acquired domestic MNEs and non-MNEs....

  15. 75 FR 18253 - R.J. Corman Railroad Property, LLC-Acquisition Exemption-NC Railroad, Inc.

    Science.gov (United States)

    2010-04-09

    ... DEPARTMENT OF TRANSPORTATION Surface Transportation Board [STB Finance Docket No. 35363] R.J. Corman Railroad Property, LLC--Acquisition Exemption--NC Railroad, Inc. R.J. Corman Railroad Property... exemption in STB Finance Docket No. 35364, R.J. Corman Railroad Company/Bardstown Line--Lease and Operation...

  16. Do Strategic Alliances, Acquisitions, and R

    Directory of Open Access Journals (Sweden)

    Martynov Aleksey

    2016-01-01

    Full Text Available This paper studies possible complementarities and substitution effects between such strategic choices as alliances, acquisitions and internal R&D investments. The findings indicate that a firm’s absorptive capacity affects the presence of complementarities and substitution effects among those strategic choices. Firms with high absorptive capacity exhibit substitution effects between alliances and acquisitions and between alliances and internal R&D investments. Firms with high absorptive capacity also exhibit complementarities between acquisitions and additional R&D investments. These results were obtained from panel data of large and medium U.S. companies spanning the years 1998-2009. The results are robust to the use of different measures of performance: profitability, market-to-book value, and sales growth. This paper contributes to our understanding of the role of absorptive capacity for the optimal choice of inter-organizational strategy vs. greater internal R&D investments.

  17. 29 CFR 401.10 - Labor organization engaged in an industry affecting commerce.

    Science.gov (United States)

    2010-07-01

    ... commerce. 401.10 Section 401.10 Labor Regulations Relating to Labor OFFICE OF LABOR-MANAGEMENT STANDARDS... organization engaged in an industry affecting commerce. A labor organization shall be deemed to be engaged in an industry affecting commerce if it: (a) Is the certified representative of employees under the...

  18. 76 FR 39155 - R.J. Corman Railroad Property, LLC-Acquisition Exemption-NC Railroad, Inc

    Science.gov (United States)

    2011-07-05

    ... DEPARTMENT OF TRANSPORTATION Surface Transportation Board [Docket No. FD 35363] R.J. Corman Railroad Property, LLC--Acquisition Exemption--NC Railroad, Inc R. J. Corman Railroad Property, LLC (RJC... is related to the notice of exemption in Docket No. FD 35364, R. J. Corman Railroad Company/Bardstown...

  19. MR-sialography: optimisation and evaluation of an ultra-fast sequence in parallel acquisition technique and different functional conditions of salivary glands

    International Nuclear Information System (INIS)

    Habermann, C.R.; Cramer, M.C.; Aldefeld, D.; Weiss, F.; Kaul, M.G.; Adam, G.; Graessner, J.; Reitmeier, F.; Jaehne, M.; Petersen, K.U.

    2005-01-01

    Purpose: To optimise a fast sequence for MR-sialography and to compare a parallel and non-parallel acquisition technique. Additionally, the effect of oral stimulation regarding the image quality was evaluated. Material and Methods: All examinations were performed by using a 1.5-T superconducting system. After developing a sufficient sequence for MR-sialography, a single-shot turbo-spin-echo sequence (ss-TSE) with an acquisition time of 2.8 sec was used in transverse and oblique sagittal orientation in 27 healthy volunteers. All images were performed with and without parallel imaging technique. The assessment of the ductal system of the submandibular and parotid gland was performed using a 1 to 5 visual scale for each side separately. Images were evaluated by four independent experienced radiologists. For statistical evaluation, an ANOVA with post-hoc comparisons was used with an overall two-tailed significance level of P=.05. For evaluation of interobserver variability, an intraclass correlation was computed and correlation >.08 was determined to indicate a high correlation. Results: All parts of salivary excretal ducts could be visualised in all volunteers, with an overall rating for all ducts of 2.26 (SD±1.09). Between the four observers a high correlation could be obtained with an intraclass correlation of 0.9475. A significant influence regarding the slice angulations could not be obtained (p=0.74). In all healthy volunteers the visibility of excretory ducts improved significantly after oral application of a Sialogogum (p 2 =0.049). The use of a parallel imaging technique did not lead to an improvement of visualisation, showing a significant loss of image quality compared to an acquistion technique without parallel imaging (p 2 =0.013). Conclusion: The optimised ss-TSE MR-sialography seems to be a fast and sufficient technique for visualisation of excretory ducts of the main salivary glands, with no elaborate post-processing needed. To improve results of MR

  20. Evaluation of attenuation correction in cardiac PET using PET/MR.

    Science.gov (United States)

    Lau, Jeffrey M C; Laforest, R; Sotoudeh, H; Nie, X; Sharma, S; McConathy, J; Novak, E; Priatna, A; Gropler, R J; Woodard, P K

    2017-06-01

    Simultaneous acquisition Positron emission tomography/magnetic resonance (PET/MR) is a new technology that has potential as a tool both in research and clinical diagnosis. However, cardiac PET acquisition has not yet been validated using MR imaging for attenuation correction (AC). The goal of this study is to evaluate the feasibility of PET imaging using a standard 2-point Dixon volume interpolated breathhold examination (VIBE) MR sequence for AC. Evaluation was performed in both phantom and patient data. A chest phantom containing heart, lungs, and a lesion insert was scanned by both PET/MR and PET/CT. In addition, 30 patients underwent whole-body 18 F-fluorodeoxyglucose PET/CT followed by simultaneous cardiac PET/MR. Phantom study showed 3% reduction of activity values in the myocardium due to the non-inclusion of the phased array coil in the AC. In patient scans, average standardized uptake values (SUVs) obtained by PET/CT and PET/MR showed no significant difference (n = 30, 4.6 ± 3.5 vs 4.7 ± 2.8, P = 0.47). There was excellent per patient correlation between the values acquired by PET/CT and PET/MR (R 2  = 0.97). Myocardial SUVs PET imaging using MR for AC shows excellent correlation with myocardial SUVs obtained by standard PET/CT imaging. The 2-point Dixon VIBE MR technique can be used for AC in simultaneous PET/MR data acquisition.

  1. f(R) gravity solutions for evolving wormholes

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Subhra [Presidency University, Department of Mathematics, Kolkata (India); Chakraborty, Subenoy [Jadavpur University, Department of Mathematics, Kolkata (India)

    2017-08-15

    The scalar-tensor f(R) theory of gravity is considered in the framework of a simple inhomogeneous space-time model. In this research we use the reconstruction technique to look for possible evolving wormhole solutions within viable f(R) gravity formalism. These f(R) models are then constrained so that they are consistent with existing experimental data. Energy conditions related to the matter threading the wormhole are analyzed graphically and are in general found to obey the null energy conditions (NEC) in regions around the throat, while in the limit f(R) = R, NEC can be violated at large in regions around the throat. (orig.)

  2. MR-sialography: optimisation and evaluation of an ultra-fast sequence in parallel acquisition technique and different functional conditions of salivary glands; MR-Sialographie: Optimierung und Bewertung ultraschneller Sequenzen mit paralleler Bildgebung und oraler Stimulation

    Energy Technology Data Exchange (ETDEWEB)

    Habermann, C.R.; Cramer, M.C.; Aldefeld, D.; Weiss, F.; Kaul, M.G.; Adam, G. [Radiologisches Zentrum, Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Graessner, J. [Siemens Medical Systems, Hamburg (Germany); Reitmeier, F.; Jaehne, M. [Kopf- und Hautzentrum, Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde, Universitaetsklinikum Hamburg-Eppendorf (Germany); Petersen, K.U. [Zentrum fuer Psychosoziale Medizin, Klinik und Poliklinik fuer Psychiatrie und Psychotherapie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2005-04-01

    Purpose: To optimise a fast sequence for MR-sialography and to compare a parallel and non-parallel acquisition technique. Additionally, the effect of oral stimulation regarding the image quality was evaluated. Material and Methods: All examinations were performed by using a 1.5-T superconducting system. After developing a sufficient sequence for MR-sialography, a single-shot turbo-spin-echo sequence (ss-TSE) with an acquisition time of 2.8 sec was used in transverse and oblique sagittal orientation in 27 healthy volunteers. All images were performed with and without parallel imaging technique. The assessment of the ductal system of the submandibular and parotid gland was performed using a 1 to 5 visual scale for each side separately. Images were evaluated by four independent experienced radiologists. For statistical evaluation, an ANOVA with post-hoc comparisons was used with an overall two-tailed significance level of P=.05. For evaluation of interobserver variability, an intraclass correlation was computed and correlation >.08 was determined to indicate a high correlation. Results: All parts of salivary excretal ducts could be visualised in all volunteers, with an overall rating for all ducts of 2.26 (SD{+-}1.09). Between the four observers a high correlation could be obtained with an intraclass correlation of 0.9475. A significant influence regarding the slice angulations could not be obtained (p=0.74). In all healthy volunteers the visibility of excretory ducts improved significantly after oral application of a Sialogogum (p<0.001; {eta}{sup 2}=0.049). The use of a parallel imaging technique did not lead to an improvement of visualisation, showing a significant loss of image quality compared to an acquistion technique without parallel imaging (p<0.001; {eta}{sup 2}=0.013). Conclusion: The optimised ss-TSE MR-sialography seems to be a fast and sufficient technique for visualisation of excretory ducts of the main salivary glands, with no elaborate post

  3. 77 FR 44064 - Federal Acquisition Regulation: Clarification of Standards for Computer Generation of Forms

    Science.gov (United States)

    2012-07-26

    ... Federal Register at 73 FR 51276 on September 2, 2008, by the Department of Commerce. This FIPS requirement was withdrawn by the Secretary of Commerce because it was obsolete and had not been updated to adopt...) 12866 and 13563 direct agencies to assess all costs and benefits of available regulatory alternatives...

  4. Clinical evaluation of PET image quality as a function of acquisition time in a new TOF-PET/MR compared to TOF-PET/CT - initial results

    International Nuclear Information System (INIS)

    Zeimpekis, Konstantinos; Huellner, Martin; De Galiza Barbosa, Felipe; Ter Voert, Edwin; Davison, Helen; Delso, Gaspar; Veit-Haibach, Patrick

    2015-01-01

    The recently available integrated PET/MR imaging can offer significant additional advances in clinical imaging. The purpose of this study was to compare the PET performance between a PET/CT scanner and an integrated TOF-PET/MR scanner concerning image quality parameters and quantification in terms of SUV as a function of acquisition time (a surrogate of dose). Five brain and five whole body patients were included in the study. The PET/CT scan was used as a reference and the PET/MR acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts and noise were evaluated. SUV measurements were taken in the liver and in white matter to compare quantification. Quantitative evaluation showed good correlation between PET/CT and PET/MR brain SUVs. Liver correlation was lower, with uptake underestimation in PET/MR, partially justified by bio-redistribution. The clinical evaluation showed that PET/MR offers higher image quality and sharpness with lower levels of noise and artefacts compared to PET/CT with reduced acquisition times for whole body scans, while for brain scans there is no significant difference. The PET-component of the TOF-PET/MR showed higher image quality compared to PET/CT as tested with reduced imaging times. However, these results account mainly for body imaging, while no significant difference were found in brain imaging. This overall higher image quality suggests that the acquisition time or injected activity can be reduced by at least 37% on the PET/MR scanner.

  5. Clinical evaluation of PET image quality as a function of acquisition time in a new TOF-PET/MR compared to TOF-PET/CT - initial results

    Energy Technology Data Exchange (ETDEWEB)

    Zeimpekis, Konstantinos; Huellner, Martin; De Galiza Barbosa, Felipe; Ter Voert, Edwin; Davison, Helen; Delso, Gaspar; Veit-Haibach, Patrick [Nuclear Medicine, University Hospital Zurich (Switzerland)

    2015-05-18

    The recently available integrated PET/MR imaging can offer significant additional advances in clinical imaging. The purpose of this study was to compare the PET performance between a PET/CT scanner and an integrated TOF-PET/MR scanner concerning image quality parameters and quantification in terms of SUV as a function of acquisition time (a surrogate of dose). Five brain and five whole body patients were included in the study. The PET/CT scan was used as a reference and the PET/MR acquisition time was consecutively adjusted, taking into account the decay between the scans in order to expose both systems to the same amount of emitted signal. The acquisition times were then retrospectively reduced to assess the performance of the PET/MRI for lower count rates. Image quality, image sharpness, artifacts and noise were evaluated. SUV measurements were taken in the liver and in white matter to compare quantification. Quantitative evaluation showed good correlation between PET/CT and PET/MR brain SUVs. Liver correlation was lower, with uptake underestimation in PET/MR, partially justified by bio-redistribution. The clinical evaluation showed that PET/MR offers higher image quality and sharpness with lower levels of noise and artefacts compared to PET/CT with reduced acquisition times for whole body scans, while for brain scans there is no significant difference. The PET-component of the TOF-PET/MR showed higher image quality compared to PET/CT as tested with reduced imaging times. However, these results account mainly for body imaging, while no significant difference were found in brain imaging. This overall higher image quality suggests that the acquisition time or injected activity can be reduced by at least 37% on the PET/MR scanner.

  6. 76 FR 25566 - Defense Federal Acquisition Regulation Supplement (DFARS); Electronic Ordering Procedures (DFARS...

    Science.gov (United States)

    2011-05-05

    ... officials to specify e-mail as an ``electronic commerce method'' so long as it is authorized in the schedule... recognized electronic commerce method. The respondent recommended, in the alternative, that the Government... stated that electronic commerce is a term specifically identified in Federal Acquisition Regulation (FAR...

  7. VIBE with parallel acquisition technique - a novel approach to dynamic contrast-enhanced MR imaging of the liver

    International Nuclear Information System (INIS)

    Dobritz, M.; Radkow, T.; Bautz, W.; Fellner, F.A.; Nittka, M.

    2002-01-01

    Purpose: The VIBE (volume interpolated breath-hold examination) sequence in combination with parallel acquisition technique (iPAT: integrated parallel acquisition technique) allows dynamic contrast-enhanced MRI of the liver with high temporal and spatial resolution. The aim of this study was to obtain first clinical experience with this technique for the detection and characterization of focal liver lesions. Materials and Methods: We examined 10 consecutive patients using a 1.5 T MR system (gradient field strength 30 mT/m) with a phased-array coil combination. Following sequences- were acquired: T 2 -w TSE and T 1 -w FLASH, after administration of gadolinium, 6 VIBE sequences with iPAT (TR/TE/matrix/partition thickness/time of acquisition: 6.2 ms/ 3.2 ms/256 x 192/4 mm/13 s), as well as T 1 -weighted FLASH with fat saturation. Two observers evaluated the different sequences concerning the number of lesions and their dignity. Following lesions were found: hepatocellular carcinoma (5 patients), hemangioma (2), metastasis (1), cyst (1), adenoma (1). Results: The VIBE sequences were superior for the detection of lesions with arterial hyperperfusion with a total of 33 focal lesions. 21 lesions were found with T 2 -w TSE and 20 with plain T 1 -weighted FLASH. Diagnostic accuracy increased with the VIBE sequence in comparison to the other sequences. Conclusion: VIBE with iPAT allows MR imaging of the liver with high spatial and temporal resolution providing dynamic contrast-enhanced information about the whole liver. This may lead to improved detection of liver lesions, especially hepatocellular carcinoma. (orig.) [de

  8. Advanced design of fast reactor-membrane reformer (FR-MR)

    International Nuclear Information System (INIS)

    Tashimo, M.; Hori, I.; Yasuda, I.; Shirasaki, Y.; Kobayashi, K.

    2004-01-01

    A new plant concept of nuclear-produced hydrogen is being studied using a Fast Reactor-Membrane Reformer (FR-MR). The conventional steam methane reforming (SMR) system is a three-stage process. The first stage includes the reforming, the second contains a shift reaction and the third is the separation process. The reforming process requires high temperatures of 800 ∼ 900 deg C. The shift process generates heat and is performed at around 200 deg C. The membrane reforming has only one process stage under a nonequilibrium condition by removing H2 selectively through a membrane tube. The steam reforming temperature can be decreased from 800 deg C to 550 deg C, which is a remarkable benefit offered by the non-equilibrium condition. With this new technology, the reactor type can be changed from a High Temperature Gas-cooled Reactor (HTGR) to a Fast Reactor (FR). A Fast Reactor-Membrane Reformer (FR-MR) is composed of a nuclear plant and a hydrogen plant. The nuclear plant is a sodium-cooled Fast Reactor with mixed oxide fuel and with a power of 240 MWt. The heat transport system contains two circuits, the primary circuit and the secondary circuit. The membrane reformer units are set in the secondary circuit. The heat, supplied by the sodium, can produce 200 000 Nm 3 /h by 2 units. There are two types of membranes. One is made of Pd another one (advanced) is made of, for example V, or Nb. The technology for the Pd membrane is already established in a small scale. The non-Pd type is expected to improve the performance. (author)

  9. Exploring plane-symmetric solutions in f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Shamir, M. F., E-mail: farasat.shamir@nu.edu.pk [National University of Computer and Emerging Sciences, Department of Sciences and Humanities (Pakistan)

    2016-02-15

    The modified theories of gravity, especially the f(R) gravity, have attracted much attention in the last decade. This paper is devoted to exploring plane-symmetric solutions in the context of metric f(R) gravity. We extend the work on static plane-symmetric vacuum solutions in f(R) gravity already available in the literature [1, 2]. The modified field equations are solved using the assumptions of both constant and nonconstant scalar curvature. Some well-known solutions are recovered with power-law and logarithmic forms of f(R) models.

  10. Disentangling the f(R). Duality

    International Nuclear Information System (INIS)

    Broy, Benedict J.; Westphal, Alexander; Pedro, Francisco G.; Univ. Autonoma de Madrid

    2014-11-01

    Motivated by UV realisations of Starobinsky-like inflation models, we study generic exponential plateau-like potentials to understand whether an exact f(R)-formulation may still be obtained when the asymptotic shift-symmetry of the potential is broken for larger field values. Potentials which break the shift symmetry with rising exponentials at large field values only allow for corresponding f(R)-descriptions with a leading order term R n with 1 2 -term survives as part of a series expansion of the function f(R) and thus cannot maintain a plateau for all field values. We further find a lean and instructive way to obtain a function f(R) describing m 2 φ 2 -inflation which breaks the shift symmetry with a monomial, and corresponds to effectively logarithmic corrections to an R+R 2 model. These examples emphasise that higher order terms in f(R)-theory may not be neglected if they are present at all. Additionally, we relate the function f(R) corresponding to chaotic inflation to a more general Jordan frame set-up. In addition, we consider f(R)-duals of two given UV examples, both from supergravity and string theory. Finally, we outline the CMB phenomenology of these models which show effects of power suppression at low-l.

  11. Geodesic congruences in the Palatini f(R) theory

    International Nuclear Information System (INIS)

    Shojai, Fatimah; Shojai, Ali

    2008-01-01

    We shall investigate the properties of a congruence of geodesics in the framework of Palatini f(R) theories. We shall evaluate the modified geodesic deviation equation and the Raychaudhuri's equation and show that f(R) Palatini theories do not necessarily lead to attractive forces. Also, we shall study energy condition for f(R) Palatini gravity via a perturbative analysis of the Raychaudhuri's equation.

  12. Clustering of galaxies with f(R) gravity

    Science.gov (United States)

    Capozziello, Salvatore; Faizal, Mir; Hameeda, Mir; Pourhassan, Behnam; Salzano, Vincenzo; Upadhyay, Sudhaker

    2018-02-01

    Based on thermodynamics, we discuss the galactic clustering of expanding Universe by assuming the gravitational interaction through the modified Newton's potential given by f(R) gravity. We compute the corrected N-particle partition function analytically. The corrected partition function leads to more exact equations of state of the system. By assuming that the system follows quasi-equilibrium, we derive the exact distribution function that exhibits the f(R) correction. Moreover, we evaluate the critical temperature and discuss the stability of the system. We observe the effects of correction of f(R) gravity on the power-law behaviour of particle-particle correlation function also. In order to check the feasibility of an f(R) gravity approach to the clustering of galaxies, we compare our results with an observational galaxy cluster catalogue.

  13. Nonlinear evolution of f(R) cosmologies. I. Methodology

    International Nuclear Information System (INIS)

    Oyaizu, Hiroaki

    2008-01-01

    We introduce the method and the implementation of a cosmological simulation of a class of metric-variation f(R) models that accelerate the cosmological expansion without a cosmological constant and evade solar-system bounds of small-field deviations to general relativity. Such simulations are shown to reduce to solving a nonlinear Poisson equation for the scalar degree of freedom introduced by the f(R) modifications. We detail the method to efficiently solve the nonlinear Poisson equation by using a Newton-Gauss-Seidel relaxation scheme coupled with the multigrid method to accelerate the convergence. The simulations are shown to satisfy tests comparing the simulated outcome to analytical solutions for simple situations, and the dynamics of the simulations are tested with orbital and Zeldovich collapse tests. Finally, we present several static and dynamical simulations using realistic cosmological parameters to highlight the differences between standard physics and f(R) physics. In general, we find that the f(R) modifications result in stronger gravitational attraction that enhances the dark matter power spectrum by ∼20% for large but observationally allowed f(R) modifications. A more detailed study of the nonlinear f(R) effects on the power spectrum are presented in a companion paper.

  14. Solar System constraints to general f(R) gravity

    International Nuclear Information System (INIS)

    Chiba, Takeshi; Smith, Tristan L.; Erickcek, Adrienne L.

    2007-01-01

    It has been proposed that cosmic acceleration or inflation can be driven by replacing the Einstein-Hilbert action of general relativity with a function f(R) of the Ricci scalar R. Such f(R) gravity theories have been shown to be equivalent to scalar-tensor theories of gravity that are incompatible with Solar System tests of general relativity, as long as the scalar field propagates over Solar System scales. Specifically, the parameterized post-Newtonian (PPN) parameter in the equivalent scalar-tensor theory is γ=1/2, which is far outside the range allowed by observations. In response to a flurry of papers that questioned the equivalence of f(R) theory to scalar-tensor theories, it was recently shown explicitly, without resorting to the scalar-tensor equivalence, that the vacuum field equations for 1/R gravity around a spherically symmetric mass also yield γ=1/2. Here we generalize this analysis to f(R) gravity and enumerate the conditions that, when satisfied by the function f(R), lead to the prediction that γ=1/2

  15. f(R) gravity and chameleon theories

    International Nuclear Information System (INIS)

    Brax, Philippe; Bruck, Carsten van de; Davis, Anne-Christine; Shaw, Douglas J.

    2008-01-01

    We analyze f(R) modifications of Einstein's gravity as dark energy models in the light of their connection with chameleon theories. Formulated as scalar-tensor theories, the f(R) theories imply the existence of a strong coupling of the scalar field to matter. This would violate all experimental gravitational tests on deviations from Newton's law. Fortunately, the existence of a matter dependent mass and a thin-shell effect allows one to alleviate these constraints. The thin-shell condition also implies strong restrictions on the cosmological dynamics of the f(R) theories. As a consequence, we find that the equation of state of dark energy is constrained to be extremely close to -1 in the recent past. We also examine the potential effects of f(R) theories in the context of the Eoet-wash experiments. We show that the requirement of a thin shell for the test bodies is not enough to guarantee a null result on deviations from Newton's law. As long as dark energy accounts for a sizeable fraction of the total energy density of the Universe, the constraints that we deduce also forbid any measurable deviation of the dark energy equation of state from -1. All in all, we find that both cosmological and laboratory tests imply that f(R) models are almost coincident with a ΛCDM model at the background level.

  16. Stellar equilibrium configurations of white dwarfs in the f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, G.A.; Moraes, P.H.R.S.; Marinho, R.M.; Malheiro, M. [Instituto Tecnologico de Aeronautica, Departamento de Fisica, Sao Jose dos Campos, SP (Brazil); Lobato, R.V. [Instituto Tecnologico de Aeronautica, Departamento de Fisica, Sao Jose dos Campos, SP (Brazil); Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); ICRANet, Pescara (Italy); Arbanil, Jose D.V. [Universidad Privada del Norte, Departamento de Ciencias, Lima (Peru); Otoniel, E. [Universidade Federal do Cariri, Instituto de Formacao de Professores, Brejo Santo, CE (Brazil)

    2017-12-15

    In this work we investigate the equilibrium configurations of white dwarfs in a modified gravity theory, namely, f(R, T) gravity, for which R and T stand for the Ricci scalar and trace of the energy-momentum tensor, respectively. Considering the functional form f(R, T) = R+2λT, with λ being a constant, we obtain the hydrostatic equilibrium equation for the theory. Some physical properties of white dwarfs, such as: mass, radius, pressure and energy density, as well as their dependence on the parameter λ are derived. More massive and larger white dwarfs are found for negative values of λ when it decreases. The equilibrium configurations predict a maximum mass limit for white dwarfs slightly above the Chandrasekhar limit, with larger radii and lower central densities when compared to standard gravity outcomes. The most important effect of f(R, T) theory for massive white dwarfs is the increase of the radius in comparison with GR and also f(R) results. By comparing our results with some observational data of massive white dwarfs we also find a lower limit for λ, namely, λ > -3 x 10{sup -4}. (orig.)

  17. 75 FR 13131 - General Services Administration Acquisition Regulation; Submission for OMB Review; GSA Advantage...

    Science.gov (United States)

    2010-03-18

    ... Electronic Commerce- FACNET AGENCY: Office of the Chief Acquisition Officer, GSA. ACTION: Notice of a request... requirement regarding GSA Advantage![reg] and Electronic Commerce-FACNET. A request for public comments was..., Washington, DC 20405. Please cite OMB Control No. 3090-00XX, GSA Advantage![reg] and Electronic Commerce...

  18. Dynamics of anisotropic power-law f(R) cosmology

    International Nuclear Information System (INIS)

    Shamir, M. F.

    2016-01-01

    Modified theories of gravity have attracted much attention of the researchers in the recent years. In particular, the f(R) theory has been investigated extensively due to important f(R) gravity models in cosmological contexts. This paper is devoted to exploring an anisotropic universe in metric f(R) gravity. A locally rotationally symmetric Bianchi type I cosmological model is considered for this purpose. Exact solutions of modified field equations are obtained for a well-known f(R) gravity model. The energy conditions are also discussed for the model under consideration. The viability of the model is investigated via graphical analysis using the present-day values of cosmological parameters. The model satisfies null energy, weak energy, and dominant energy conditions for a particular range of the anisotropy parameter while the strong energy condition is violated, which shows that the anisotropic universe in f(R) gravity supports the crucial issue of accelerated expansion of the universe.

  19. Dynamics of anisotropic power-law f(R) cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Shamir, M. F., E-mail: farasat.shamir@nu.edu.pk [National University of Computer and Emerging Sciences, Lahore Campus, Department of Sciences and Humanities (Pakistan)

    2016-12-15

    Modified theories of gravity have attracted much attention of the researchers in the recent years. In particular, the f(R) theory has been investigated extensively due to important f(R) gravity models in cosmological contexts. This paper is devoted to exploring an anisotropic universe in metric f(R) gravity. A locally rotationally symmetric Bianchi type I cosmological model is considered for this purpose. Exact solutions of modified field equations are obtained for a well-known f(R) gravity model. The energy conditions are also discussed for the model under consideration. The viability of the model is investigated via graphical analysis using the present-day values of cosmological parameters. The model satisfies null energy, weak energy, and dominant energy conditions for a particular range of the anisotropy parameter while the strong energy condition is violated, which shows that the anisotropic universe in f(R) gravity supports the crucial issue of accelerated expansion of the universe.

  20. Multiple half-second acquisition method of the moving knee joint. Kinematic MR imaging of the anterior cruciate ligament

    Energy Technology Data Exchange (ETDEWEB)

    Niitsu, Mamoru; Ikeda, Kotaroh; Fukubayashi, Tohru; Echigo, Junko; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    1996-10-01

    The objective of this study was to delineate the moving anterior cruciate ligament (ACL) with multiple rapid magnetic resonance (MR) imaging. Rapid gradient echo MR images with an one-shot acquisition time of a half-second were accomplished by short repetition time and phase encoding reduction. Using a mobile knee brace and a flexible surface coil, half-second acquisitions were sequentially acquired during active, constant knee movement. Sixteen knees with intact ACLs and 27 knees with arthroscopically proven ACL tears were examined. Normal ACLs were identified as moving linear low-intensities. The ligaments were readily identified as straight or minimally curved structures when the knee was in semi-flexion compared to the knee extension. Torn ACLs were demonstrated as moving fragments or an amorphous configuration. Intermittent appearances of joint fluid interrupted the ligamentous continuities. Compared to the static images, no significant superiority of the kinematic imaging was found in diagnosis of ACL tears. However, this instant kinematic imaging is feasible with a standard MR system and can provide morphological information for functional analysis of the knee. (author)

  1. 76 FR 46206 - NASA Implementation of Federal Acquisition Regulation (FAR) Award Fee Language Revision

    Science.gov (United States)

    2011-08-02

    ... of Federal Acquisition Regulation (FAR) Award Fee Language Revision AGENCY: National Aeronautics and... Acquisition Circular (FAC) 2005-46. DATES: Effective Date: August 2, 2011. FOR FURTHER INFORMATION CONTACT... on February 8, 2011 (76 FR 6696) implementing Federal Acquisition Circular (FAC) 2005-46 which...

  2. WE-AB-204-06: Pseudo-CT Generation Using Undersampled, Single-Acquisition UTE-MDixon and Direct-Mapping Artificial Neural Networks for MR-Based Attenuation Correction and Radiation Therapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Su, K; Kuo, J [Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio (United States); Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, Ohio (United States); Hu, L; Traughber, M [Philips Healthcare, Cleveland, Ohio (United States); Pereira, G; Traughber, B [Department of Radiation Oncology, University Hospitals Seidman Cancer Center, Case Western Reserve University, Cleveland, Ohio (United States); Herrmann, K [Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, Ohio (United States); Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, Ohio (United States); Muzic, R [Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio (United States); Department of Radiology, University Hospitals Case Medical Center, Case Western Reserve University, Cleveland, Ohio (United States); Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH (United States)

    2015-06-15

    Purpose: Emerging technologies such as dedicated PET/MRI and MR-therapy systems require robust and clinically practical methods for determining photon attenuation. Herein, we propose using novel MR acquisition methods and processing for the generation of pseudo-CTs. Methods: A single acquisition, 190-second UTE-mDixon sequence with 25% (angular) sampling density and 3D radial readout was performed on nine volunteers. Three water-filled tubes were placed in the FOV for trajectory-delay correction. The MR data were reconstructed to generate three primitive images acquired at TEs of 0.1, 1.5 and 2.8 ms. In addition, three derived MR images were generated, i.e. two-point Dixon water/fat separation and R2* (1/T2*) map. Furthermore, two spatial features, i.e. local binary pattern (S-1) and relative spatial coordinates (S-2), were incorporated. A direct-mapping operator was generated using Artificial Neural Networks (ANNs) for transforming the MR features to a pseudo-CT. CT images served as the training data and, using a leave-one-out method, for performance evaluation using mean prediction deviation (MPD), mean absolute prediction deviation (MAPD), and correlation coefficient (R). Results: The errors between measured CT and pseudo-CT declined dramatically when the spatial features, i.e. S-1 and S-2, were included. The MPD, MAPD, and R were, respectively, 5±57 HU, 141±41 HU, and 0.815±0.066 for results generated by the ANN trained without the spatial features and were 32±26 HU, 115±18 HU, and 0.869±0.035 with the spatial features. The estimation errors of the pseudo-CT were smaller when both the S-1 and S-2 were used together than when either the S-1 or the S-2 was used. Pseudo-CT generation (256×256×256 voxels) by ANN took < 0.5 s using a computer having an Intel i7 3.4GHz CPU and 16 GB RAM. Conclusion: The proposed direct-mapping ANN approach is a technically accurate, clinically practical method for pseudo-CT generation and can potentially help improve the

  3. WE-AB-204-06: Pseudo-CT Generation Using Undersampled, Single-Acquisition UTE-MDixon and Direct-Mapping Artificial Neural Networks for MR-Based Attenuation Correction and Radiation Therapy Planning

    International Nuclear Information System (INIS)

    Su, K; Kuo, J; Hu, L; Traughber, M; Pereira, G; Traughber, B; Herrmann, K; Muzic, R

    2015-01-01

    Purpose: Emerging technologies such as dedicated PET/MRI and MR-therapy systems require robust and clinically practical methods for determining photon attenuation. Herein, we propose using novel MR acquisition methods and processing for the generation of pseudo-CTs. Methods: A single acquisition, 190-second UTE-mDixon sequence with 25% (angular) sampling density and 3D radial readout was performed on nine volunteers. Three water-filled tubes were placed in the FOV for trajectory-delay correction. The MR data were reconstructed to generate three primitive images acquired at TEs of 0.1, 1.5 and 2.8 ms. In addition, three derived MR images were generated, i.e. two-point Dixon water/fat separation and R2* (1/T2*) map. Furthermore, two spatial features, i.e. local binary pattern (S-1) and relative spatial coordinates (S-2), were incorporated. A direct-mapping operator was generated using Artificial Neural Networks (ANNs) for transforming the MR features to a pseudo-CT. CT images served as the training data and, using a leave-one-out method, for performance evaluation using mean prediction deviation (MPD), mean absolute prediction deviation (MAPD), and correlation coefficient (R). Results: The errors between measured CT and pseudo-CT declined dramatically when the spatial features, i.e. S-1 and S-2, were included. The MPD, MAPD, and R were, respectively, 5±57 HU, 141±41 HU, and 0.815±0.066 for results generated by the ANN trained without the spatial features and were 32±26 HU, 115±18 HU, and 0.869±0.035 with the spatial features. The estimation errors of the pseudo-CT were smaller when both the S-1 and S-2 were used together than when either the S-1 or the S-2 was used. Pseudo-CT generation (256×256×256 voxels) by ANN took < 0.5 s using a computer having an Intel i7 3.4GHz CPU and 16 GB RAM. Conclusion: The proposed direct-mapping ANN approach is a technically accurate, clinically practical method for pseudo-CT generation and can potentially help improve the

  4. Effects of the kappa opioid receptor antagonist MR-2266-BS on the acquisition of ethanol preference

    Energy Technology Data Exchange (ETDEWEB)

    Sandi, C.; Borrell, J.; Guaza, C. (Cajal Institute, Madrid (Spain))

    1990-01-01

    Using a paradigm by which rats forced to drink a weak ethanol solution develop ethanol preference in consecutive retention testing days, the effects of the administration of the kappa opioid antagonist MR-2266-BS, prior to or after the forced ethanol session, were studied. Pre-conditioning subcutaneous (s.c.) administration of 1 mg/kg of MR-2266-BS induced a decrease in subsequent ethanol consumption without significantly modifying the acquisition of ethanol preference. Post-conditioning administration of MR-2266-BS induced both a dose-dependent reduction in ethanol consumption and in preference throughout the three following days. The results of the present study provide further support of the involvement of kappa-type opioids on drinking behavior, and suggest that kappa receptors may be involved in the consumption and development of preference to ethanol.

  5. Cosmology of f(R) gravity in the metric variational approach

    Science.gov (United States)

    Li, Baojiu; Barrow, John D.

    2007-04-01

    We consider the cosmologies that arise in a subclass of f(R) gravity with f(R)=R+μ2n+2/(-R)n and n∈(-1,0) in the metric (as opposed to the Palatini) variational approach to deriving the gravitational field equations. The calculations of the isotropic and homogeneous cosmological models are undertaken in the Jordan frame and at both the background and the perturbation levels. For the former, we also discuss the connection to the Einstein frame in which the extra degree of freedom in the theory is associated with a scalar field sharing some of the properties of a “chameleon” field. For the latter, we derive the cosmological perturbation equations in general theories of f(R) gravity in covariant form and implement them numerically to calculate the cosmic microwave background (CMB) temperature and matter power spectra of the cosmological model. The CMB power is shown to reduce at low l’s, and the matter power spectrum is almost scale independent at small scales, thus having a similar shape to that in standard general relativity. These are in stark contrast with what was found in the Palatini f(R) gravity, where the CMB power is largely amplified at low l’s and the matter spectrum is strongly scale dependent at small scales. These features make the present model more adaptable than that arising from the Palatini f(R) field equations, and none of the data on background evolution, CMB power spectrum, or matter power spectrum currently rule it out.

  6. MR investigation of recurrent cholesteatomas

    International Nuclear Information System (INIS)

    Doyon, D.; Chan, K.Y.; Attia, M.; Halimi, P.; Sigal, R.; Bobin, S.; Sterkers, J.M.

    1989-01-01

    Nine cases of recurrent petrous cholesteatomas have been studied by a 1.5 T MR unit. Gadolinium was injected in 1 case. In all cases, comparison between MR, CT and clinical findings were made. MR allows for accurate topographic study and assessment of cholesteatomas extension, in particular in the posterior fossa and skull base. Relationships with the internal carotid artery and the jugular vein are clearly depicted [fr

  7. Further stable neutron star models from f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Astashenok, Artyom V. [I. Kant Baltic Federal University, Institute of Physics and Technology, Nevskogo st. 14, Kaliningrad, 236041 (Russian Federation); Capozziello, Salvatore [Dipartimento di Fisica, Università di Napoli ' ' Federico II' ' , Via Cinthia, 9, Napoli, I–80126 (Italy); Odintsov, Sergei D., E-mail: artyom.art@gmail.com, E-mail: capozziello@na.infn.it, E-mail: odintsov@ieec.uab.es [Instituciò Catalana de Recerca i Estudis Avançats (ICREA), Barcelona (Spain)

    2013-12-01

    Neutron star models in perturbative f(R) gravity are considered with realistic equations of state. In particular, we consider the FPS, SLy and other equations of state and a case of piecewise equation of state for stars with quark cores. The mass-radius relations for f(R) = R+R(e{sup −R/R{sub 0}}−1) model and for R{sup 2} models with logarithmic and cubic corrections are obtained. In the case of R{sup 2} gravity with cubic corrections, we obtain that at high central densities (ρ > 10ρ{sub ns}, where ρ{sub ns} = 2.7 × 10{sup 14} g/cm{sup 3} is the nuclear saturation density), stable star configurations exist. The minimal radius of such stars is close to 9 km with maximal mass ∼ 1.9M{sub ⊙} (SLy equation). A similar situation takes place for AP4 and BSK20 EoS. Such an effect can give rise to more compact stars than in General Relativity. If observationally identified, such objects could constitute a formidable signature for modified gravity at astrophysical level. Another interesting result can be achieved in modified gravity with only a cubic correction. For some EoS, the upper limit of neutron star mass increases and therefore these EoS can describe realistic star configurations (although, in General Relativity, these EoS are excluded by observational constraints)

  8. Further stable neutron star models from f(R) gravity

    International Nuclear Information System (INIS)

    Astashenok, Artyom V.; Capozziello, Salvatore; Odintsov, Sergei D.

    2013-01-01

    Neutron star models in perturbative f(R) gravity are considered with realistic equations of state. In particular, we consider the FPS, SLy and other equations of state and a case of piecewise equation of state for stars with quark cores. The mass-radius relations for f(R) = R+R(e −R/R 0 −1) model and for R 2 models with logarithmic and cubic corrections are obtained. In the case of R 2 gravity with cubic corrections, we obtain that at high central densities (ρ > 10ρ ns , where ρ ns = 2.7 × 10 14 g/cm 3 is the nuclear saturation density), stable star configurations exist. The minimal radius of such stars is close to 9 km with maximal mass ∼ 1.9M ⊙ (SLy equation). A similar situation takes place for AP4 and BSK20 EoS. Such an effect can give rise to more compact stars than in General Relativity. If observationally identified, such objects could constitute a formidable signature for modified gravity at astrophysical level. Another interesting result can be achieved in modified gravity with only a cubic correction. For some EoS, the upper limit of neutron star mass increases and therefore these EoS can describe realistic star configurations (although, in General Relativity, these EoS are excluded by observational constraints)

  9. SU-E-J-237: Real-Time 3D Anatomy Estimation From Undersampled MR Acquisitions

    Energy Technology Data Exchange (ETDEWEB)

    Glitzner, M; Lagendijk, J; Raaymakers, B; Crijns, S [University Medical Center Utrecht, Utrecht (Netherlands); Senneville, B Denis de [University Medical Center Utrecht, Utrecht (Netherlands); Mathematical Institute of Bordeaux, University of Bordeaux, Talence Cedex (France)

    2015-06-15

    Recent developments made MRI guided radiotherapy feasible. Performing simultaneous imaging during fractions can provide information about changing anatomy by means of deformable image registration for either immediate plan adaptations or accurate dose accumulation on the changing anatomy. In 3D MRI, however, acquisition time is considerable and scales with resolution. Furthermore, intra-scan motion degrades image quality.In this work, we investigate the sensitivity of registration quality on imageresolution: potentially, by employing spatial undersampling, the acquisition timeof MR images for the purpose of deformable image registration can be reducedsignificantly.On a volunteer, 3D-MR imaging data was sampled in a navigator-gated manner, acquiring one axial volume (360×260×100mm{sup 3}) per 3s during exhale phase. A T1-weighted FFE sequence was used with an acquired voxel size of (2.5mm{sup 3}) for a duration of 17min. Deformation vector fields were evaluated for 100 imaging cycles with respect to the initial anatomy using deformable image registration based on optical flow. Subsequently, the imaging data was downsampled by a factor of 2, simulating a fourfold acquisition speed. Displacements of the downsampled volumes were then calculated by the same process.In kidneyliver boundaries and the region around stomach/duodenum, prominent organ drifts could be observed in both the original and the downsampled imaging data. An increasing displacement of approximately 2mm was observed for the kidney, while an area around the stomach showed sudden displacements of 4mm. Comparison of the motile points over time showed high reproducibility between the displacements of high-resolution and downsampled volumes: over a 17min acquisition, the componentwise RMS error was not more than 0.38mm.Based on the synthetic experiments, 3D nonrigid image registration shows little sensitivity to image resolution and the displacement information is preserved even when halving the

  10. Benthic organism collected using sediment sampler, BT, and bottle casts from the EASTWARD and other platforms in Georges' Bank from 10 July 1981 to 08 June 1983 (NODC Accession 8500125)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Benthic organism were collected using sediment sampler, BT, and bottle casts from the EASTWARD and other platforms in the Georges' Bank from 10 July 1981 to 08 June...

  11. 15 CFR 19.10 - How will Commerce entities use administrative offset (offset of non-tax Federal payments) to...

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false How will Commerce entities use administrative offset (offset of non-tax Federal payments) to collect a Commerce debt? 19.10 Section 19.10 Commerce and Foreign Trade Office of the Secretary of Commerce COMMERCE DEBT COLLECTION Procedures To...

  12. MR equipment acquisition strategies: low-field or high-field scanners

    International Nuclear Information System (INIS)

    Marti-Bonmati, L.; Kormano, M.

    1997-01-01

    Magnetic resonance (MR) field strength is one of the key aspects to consider when purchasing MR equipment. Other aspects include the gradient system, coil design, computer and pulse sequence availability, purchase cost, local reimbursement policies, and current opinion within the medical community. Our objective here is to evaluate the decision-influencing aspects of the MR market, with a focus on some specific areas such as high resolution studies, examination times, special techniques, instrumentation, open design magnets, costs and reimbursement policies, academic and industrial interests, contrast media, clinical efficacy, and finally, clinicians' preferences. Certainly the advantage of high-field is a higher signal-to-noise ratio and improved resolution. With a high-field unit, higher spatial resolution images and higher temporal resolution images can be obtained. Typical imaging times needed to produce clinically diagnostic images are about 3 times longer at 0.1 T than at 1.0 or 1.5 T. High-field-related advanced techniques, such as functional imaging, spectroscopy and microscopy, may become clinically useful in the near future. As long as there is an unlimited demand for MR examinations, it appears financially profitable to run a high-field system, despite the associated higher costs. However, if demand for MR becomes saturated, low-field systems will cause less financial strain on the reimbursement organisation and service provider. Recent emphasis on cost containment, the development of interventional techniques, the increased use of MR for patients in intensive care and operating suites, the deployment of magnets in office suites, and the development of new magnet configurations, all favour the supplementary use of low-field systems. Hence, MR units of all field strengths have a role in radiology. (orig.)

  13. 76 FR 10028 - Settlement Agreement for Recovery of Past Response Costs 10,000 Havana Street Site, Commerce City...

    Science.gov (United States)

    2011-02-23

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9269-7] Settlement Agreement for Recovery of Past Response Costs 10,000 Havana Street Site, Commerce City, Adams County, CO AGENCY: Environmental Protection Agency. ACTION: Notice and request for public comment. SUMMARY: In accordance with the requirements of Section...

  14. 78 FR 2996 - Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding...

    Science.gov (United States)

    2013-01-15

    ... FEDERAL RESERVE SYSTEM Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction Correction This notice corrects a notice (FR Doc. 2013-00331) published on page 2273 of the issue for Thursday, January 10, 2013. Under the Federal Reserve Bank of Kansas City heading, the entry for Whitewater...

  15. Closed string tachyon driving f(R) cosmology

    Science.gov (United States)

    Wang, Peng; Wu, Houwen; Yang, Haitang

    2018-05-01

    To study quantum effects on the bulk tachyon dynamics, we replace R with f(R) in the low-energy effective action that couples gravity, the dilaton, and the bulk closed string tachyon of bosonic closed string theory and study properties of their classical solutions. The α' corrections of the graviton-dilaton-tachyon system are implemented in the f(R). We obtain the tachyon-induced rolling solutions and show that the string metric does not need to remain fixed in some cases. In the case with H( t=‑∞ ) = , only the R and R2 terms in f(R) play a role in obtaining the rolling solutions with nontrivial metric. The singular behavior of more classical solutions are investigated and found to be modified by quantum effects. In particular, there could exist some classical solutions, in which the tachyon field rolls down from a maximum of the tachyon potential while the dilaton expectation value is always bounded from above during the rolling process.

  16. f(R) gravity, torsion and non-metricity

    International Nuclear Information System (INIS)

    Sotiriou, Thomas P

    2009-01-01

    For both f(R) theories of gravity with an independent symmetric connection (no torsion), usually referred to as Palatini f(R) gravity theories, and for f(R) theories of gravity with torsion but no non-metricity, called U4 theories, it has been shown that the independent connection can actually be eliminated algebraically, as long as this connection does not couple to matter. Remarkably, the outcome in both cases is the same theory, which is dynamically equivalent with an ω 0 = -3/2 Brans-Dicke theory. It is shown here that even for the most general case of an independent connection with both non-metricity and torsion, one arrives at exactly the same theory as in the more restricted cases. This generalizes the previous results and explains why assuming that either the torsion or the non-metricity vanishing ultimately leads to the same theory. It also demonstrates that f(R) actions cannot support an independent connection which carries dynamical degrees of freedom, irrespective of how general this connection is, at least as long as there is no connection-matter coupling. (fast track communication)

  17. Quantitative MR evaluation of body composition in patients with Duchenne muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Pichiecchio, Anna; Uggetti, Carla; Egitto, Maria Grazia [Department of Neuroradiology, Istituto Neurologico ' ' Fondazione C.Mondino' ' I.R.C.C.S, Via Palestro, 3, 27100 Pavia (Italy); Berardinelli, Angela; Orcesi, Simona; Gorni, Ksenija Olga Tatiana [Department of Neuropsychiatry, Istituto Neurologico ' ' Fondazione C.Mondino' ' I.R.C.C.S, Via Palestro, 3, 27100 Pavia (Italy); Zanardi, Cristina; Tagliabue, Anna [Department of Human Nutrition, Cascina Cravino, Via Bassi, 23, 27100 Pavia (Italy)

    2002-11-01

    The aim of this study was to propose a quantitative MR protocol with very short acquisition time and good reliability in volume construction, for the evaluation of body composition in patients affected by Duchenne muscular dystrophy (DMD). This MR protocol was compared with common anthropometric evaluations of the same patients. Nine boys affected by DMD, ranging in age from 6 to 12 years, were selected to undergo MR examination. Transversal T1-weighted spin-echo sequences (0.5T; TR 300 ms, TE 10 ms, slice thickness 10 mm, slice gap 1 mm) were used for all acquisitions, each consisting of 8 slices and lasting just 54 s. Whole-body examination needed an average of nine acquisitions. Afterwards, images were downloaded to an independent workstation and, through their electronic segmentation with a reference filter, total volume and adipose tissue volumes were calculated manually. This process took up to 2 h for each patient. The MR data were compared with anthropometric evaluations. Affected children have a marked increase in adipose tissue and a decrease in lean tissue compared with reference healthy controls. Mean fat mass calculated by MR is significantly higher than mean fat mass obtained using anthropometric measurements (p<0.001). Our MR study proved to be accurate and easy to apply, although it was time-consuming. We recommend it in monitoring the progression of the disease and planning DMD patients' diet. (orig.)

  18. Quantitative MR evaluation of body composition in patients with Duchenne muscular dystrophy

    International Nuclear Information System (INIS)

    Pichiecchio, Anna; Uggetti, Carla; Egitto, Maria Grazia; Berardinelli, Angela; Orcesi, Simona; Gorni, Ksenija Olga Tatiana; Zanardi, Cristina; Tagliabue, Anna

    2002-01-01

    The aim of this study was to propose a quantitative MR protocol with very short acquisition time and good reliability in volume construction, for the evaluation of body composition in patients affected by Duchenne muscular dystrophy (DMD). This MR protocol was compared with common anthropometric evaluations of the same patients. Nine boys affected by DMD, ranging in age from 6 to 12 years, were selected to undergo MR examination. Transversal T1-weighted spin-echo sequences (0.5T; TR 300 ms, TE 10 ms, slice thickness 10 mm, slice gap 1 mm) were used for all acquisitions, each consisting of 8 slices and lasting just 54 s. Whole-body examination needed an average of nine acquisitions. Afterwards, images were downloaded to an independent workstation and, through their electronic segmentation with a reference filter, total volume and adipose tissue volumes were calculated manually. This process took up to 2 h for each patient. The MR data were compared with anthropometric evaluations. Affected children have a marked increase in adipose tissue and a decrease in lean tissue compared with reference healthy controls. Mean fat mass calculated by MR is significantly higher than mean fat mass obtained using anthropometric measurements (p<0.001). Our MR study proved to be accurate and easy to apply, although it was time-consuming. We recommend it in monitoring the progression of the disease and planning DMD patients' diet. (orig.)

  19. Standard cosmological evolution in the f(R) model to Kaluza-Klein cosmology

    International Nuclear Information System (INIS)

    Aghmohammadi, A; Abolhassani, M R; Saaidi, Kh; Vajdi, A

    2009-01-01

    In this paper, using f(R) theory of gravity we explicitly calculate cosmological evolution in the presence of a perfect fluid source in four- and five-dimensional space-time in which this cosmological evolution in self-creation is presented by Reddy et al (2009 Int. J. Theor. Phys. 48 10). An exact cosmological model is presented using a relation between Einstein's gravity field equation components due to a metric with the same component from f(R) theory of gravity. Some physics and kinematical properties of the model are also discussed.

  20. Peer-Reviewed Research and the IEP: Implications of "Ridley School District v. M.R. and J.R. ex rel. E.R." (2012)

    Science.gov (United States)

    Yell, Mitchell L.; Katsiyannis, Antonis; Losinski, Mickey; Marshall, Kelsey

    2016-01-01

    This article examines a case out of the U.S. Court of Appeals for the Third Circuit: "Ridley School District v. M.R and J.R. ex rel. E.R." (2012). The case is the first circuit court case in which the Individuals with Disabilities Education Improvement Act requirement that special education services be based on peer-reviewed research…

  1. Validation of new 3D post processing algorithm for improved maximum intensity projections of MR angiography acquisitions in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Bosmans, H; Verbeeck, R; Vandermeulen, D; Suetens, P; Wilms, G; Maaly, M; Marchal, G; Baert, A L [Louvain Univ. (Belgium)

    1995-12-01

    The objective of this study was to validate a new post processing algorithm for improved maximum intensity projections (mip) of intracranial MR angiography acquisitions. The core of the post processing procedure is a new brain segmentation algorithm. Two seed areas, background and brain, are automatically detected. A 3D region grower then grows both regions towards each other and this preferentially towards white regions. In this way, the skin gets included into the final `background region` whereas cortical blood vessels and all brain tissues are included in the `brain region`. The latter region is then used for mip. The algorithm runs less than 30 minutes on a full dataset on a Unix workstation. Images from different acquisition strategies including multiple overlapping thin slab acquisition, magnetization transfer (MT) MRA, Gd-DTPA enhanced MRA, normal and high resolution acquisitions and acquisitions from mid field and high field systems were filtered. A series of contrast enhanced MRA acquisitions obtained with identical parameters was filtered to study the robustness of the filter parameters. In all cases, only a minimal manual interaction was necessary to segment the brain. The quality of the mip was significantly improved, especially in post Gd-DTPA acquisitions or using MT, due to the absence of high intensity signals of skin, sinuses and eyes that otherwise superimpose on the angiograms. It is concluded that the filter is a robust technique to improve the quality of MR angiograms.

  2. Validation of new 3D post processing algorithm for improved maximum intensity projections of MR angiography acquisitions in the brain

    International Nuclear Information System (INIS)

    Bosmans, H.; Verbeeck, R.; Vandermeulen, D.; Suetens, P.; Wilms, G.; Maaly, M.; Marchal, G.; Baert, A.L.

    1995-01-01

    The objective of this study was to validate a new post processing algorithm for improved maximum intensity projections (mip) of intracranial MR angiography acquisitions. The core of the post processing procedure is a new brain segmentation algorithm. Two seed areas, background and brain, are automatically detected. A 3D region grower then grows both regions towards each other and this preferentially towards white regions. In this way, the skin gets included into the final 'background region' whereas cortical blood vessels and all brain tissues are included in the 'brain region'. The latter region is then used for mip. The algorithm runs less than 30 minutes on a full dataset on a Unix workstation. Images from different acquisition strategies including multiple overlapping thin slab acquisition, magnetization transfer (MT) MRA, Gd-DTPA enhanced MRA, normal and high resolution acquisitions and acquisitions from mid field and high field systems were filtered. A series of contrast enhanced MRA acquisitions obtained with identical parameters was filtered to study the robustness of the filter parameters. In all cases, only a minimal manual interaction was necessary to segment the brain. The quality of the mip was significantly improved, especially in post Gd-DTPA acquisitions or using MT, due to the absence of high intensity signals of skin, sinuses and eyes that otherwise superimpose on the angiograms. It is concluded that the filter is a robust technique to improve the quality of MR angiograms

  3. Review Electronic Commerce Untuk Memperluas Jaringan Pemasaran

    OpenAIRE

    Sidiq, Ahmad

    2010-01-01

    To day, For the part of corporation, e-commerce bot merely buy and sell product according to online, on the contrary, e-commerce cover entire process from developments, marketing, sale, delivery, service, and payment to various product and service, buy in base global network customers, with support from network business partners throughout world. in this article be discussed about sisitem e-comerce will base on internet resource and many another information technology to support every step fr...

  4. 77 FR 43077 - Federal Acquisition Regulation; Information Collection; Economic Purchase Quantity-Supplies

    Science.gov (United States)

    2012-07-23

    ... provided. FOR FURTHER INFORMATION CONTACT: Mr. Michael Jackson, Procurement Analyst, Office of Governmentwide Acquisition Policy, (202) 208-4949 or email michaelo.jackson@gsa.gov . SUPPLEMENTARY INFORMATION...

  5. Effective Dark Matter Halo Catalog in f(R) Gravity.

    Science.gov (United States)

    He, Jian-Hua; Hawken, Adam J; Li, Baojiu; Guzzo, Luigi

    2015-08-14

    We introduce the idea of an effective dark matter halo catalog in f(R) gravity, which is built using the effective density field. Using a suite of high resolution N-body simulations, we find that the dynamical properties of halos, such as the distribution of density, velocity dispersion, specific angular momentum and spin, in the effective catalog of f(R) gravity closely mimic those in the cold dark matter model with a cosmological constant (ΛCDM). Thus, when using effective halos, an f(R) model can be viewed as a ΛCDM model. This effective catalog therefore provides a convenient way for studying the baryonic physics, the galaxy halo occupation distribution and even semianalytical galaxy formation in f(R) cosmologies.

  6. 48 CFR 53.301-26 - Award/Contract.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 2 2010-10-01 2010-10-01 false Award/Contract. 53.301-26 Section 53.301-26 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION (CONTINUED) CLAUSES AND FORMS FORMS Illustrations of Forms 53.301-26 Award/Contract. ER22AP08.000 [73 FR 21785, Apr...

  7. Constraints on perturbative f(R) gravity via neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Arapoğlu, Savaş; Ekşi, K. Yavuz [İstanbul Technical University, Faculty of Science and Letters, Physics Engineering Department, Maslak 34469, İstanbul (Turkey); Deliduman, Cemsinan, E-mail: arapoglu@itu.edu.tr, E-mail: cemsinan@msgsu.edu.tr, E-mail: eksi@itu.edu.tr [Mimar Sinan Fine Arts University, Department of Physics, Beşiktaş 34349, İstanbul (Turkey)

    2011-07-01

    We study the structure of neutron stars in perturbative f(R) gravity models with realistic equations of state. We obtain mass-radius relations in a gravity model of the form f(R) = R+αR{sup 2}. We find that deviations from the results of general relativity, comparable to the variations due to using different equations of state (EoS'), are induced for |α| ∼ 10{sup 9} cm{sup 2}. Some of the soft EoS' that are excluded within the framework of general relativity can be reconciled with the 2 solar mass neutron star recently observed for certain values of α within this range. For some of the EoS' we find that a new solution branch, which allows highly massive neutron stars, exists for values of α greater than a few 10{sup 9} cm{sup 2}. We find constraints on α for a variety of EoS' using the recent observational constraints on the mass-radius relation. These are all 5 orders of magnitude smaller than the recent constraint obtained via Gravity Probe B for this gravity model. The associated length scale √(alpha)approx 10{sup 5} cm is only an order of magnitude smaller than the typical radius of a neutron star, the probe used in this test. This implies that real deviations from general relativity can be even smaller.

  8. Drug-induced MR urography: the effects of furosemide and intravenous saline injection on MR urography of obstructed and non-obstructed urinary tract

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jeong Ha; Lee, Myung Jun; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    2001-10-01

    To determine the usefulness of MR urography technique for the evaluation of urinary systems in patients with obstructed urinary tract and normal volunteers with non-obstructed urinary tract after intravenous normal saline and diuretic injection. Three normal volunteers and 12 patients with urinary tract obstruction [ureteral calculi (n=8), extraurinary mass (n=1), ureteral tumor invasion (n=3)] underwent MR urography using a 1.0T scanner and a 2D non-breath-hold heavily T2-weighted fast spin-cho sequence. These acquisition were post-processed with a maximum intensity projection (MIP) algorithm. Two acquisitions were performed, the first prior to saline solution infusion following standard MR urography procedures, and the second, within 2-3 minutes of the infusion of 250 ml saline solution followed by 20 mg of Lasix administered intravenously. For this latter, drug-induced MR urography procedures were followed. In healthy volunteer (n=3) and those experiencing partial obstruction (n=4) by a urinary stone, drug-induced MR urography provided better images of the urinary tract than did standard MR urography. In those in whom a urinary stone or tumor had caused complete obstruction (n=8), standard MR urography provided good images, as did drug-induced MR urography. In patients with a partially or non-obstructed urinary tract, drug-induced MR urography provided better anatomic and functional details of the kidney and urinary tract than did standard MR urography. In those experiencing complete obstruction of the urinary tract, however, standard or drug-induced MR urography permitted very adequate evaluation of the tract, and drug-induced MR urography was unnecessary.

  9. The acquisition and supervision system of S.A.R.A.'s (Accelerator system Rhone-Alpes) parameters

    International Nuclear Information System (INIS)

    Iazzourene, F.

    1982-01-01

    The acquisition and supervision system of SARA's (Systeme Accelerateur Rhone-Alpes) parameters is built up. The basic hardware consists of: - A PDP 11/10 computer with a 64 K bytes memory capacity. The system and load device is a floppy disk of 28 megabytes capacity. - A CAMAC crate including a data logger with 224 input channels, a terminal driver (JTY21) and three modules designed for reading out a few digital data, for instance polarities of power supplies. The software provides three distinct programs: AKITS, which uses 3 commands, detects and signals functioning defects in the CAMAC modules used. AKIDO which uses 11 commands, is the acquisition and organization program of the accelerator's functioning parameters. AKISUR is the supervision program of the functioning parameter's stability, within a fixed gap, during the accelerator running [fr

  10. Intracranial MR angiography

    International Nuclear Information System (INIS)

    Davis, W.L.; Blatter, D.D.; Parker, D.L.; Robison, R.O.; Harnsberger, H.R.

    1991-01-01

    This paper compares the more traditional three-dimensional (3D) time-of-flight MR angiography with a novel new technique, MOTSA, in the evaluation of both normal and abnormal intracranial anatomy. The authors performed sequential, location-matched 3D TOF and MOTSA MR angiography in 10 subjects with normal and 25 with abnormal intracranial anatomy. Images were evaluated for visualization of specific vessels and depiction of pathologic anatomy. All images were subjected to an objective scoring system. Digital angiography was available in 15 of 25 abnormal cases. In the normal cases, large- and small-vessel visualization was improved. Significant improvement in visualization of venous anatomy was also observed. In the abnormal cases, pathologic anatomy was better visualized, providing important diagnostic information. Multiple overlapping thin-slab-acquisition MR angiography demonstrates vessel visualization that is increased over that of 3D TOF MR angiography in both normal and abnormal cases. Because of the decrease in saturation effects and phase dispersion, MOTSA is especially useful in the evaluation of complex intracranial vascular abnormalities

  11. Wormholes in R{sup 2}-gravity within the f(R, T) formalism

    Energy Technology Data Exchange (ETDEWEB)

    Sahoo, P.K.; Sahoo, Parbati [Birla Institute of Technology and Science-Pilani, Department of Mathematics, Hyderabad (India); Moraes, P.H.R.S. [ITA-Instituto Tecnologico de Aeronautica, Departamento de Fisica, Sao Jose dos Campos, Sao Paulo (Brazil)

    2018-01-15

    We propose, as a novelty in the literature, the modeling of wormholes within a particular case of f(R, T) gravity, namely f(R, T) = R + αR{sup 2} + λT, with R and T being the Ricci scalar and trace of the energy-momentum tensor, respectively, while α and λ are constants. Although such a functional form application can be found in the literature, those concern compact astrophysical objects, such that no wormhole analysis has been done so far. The quadratic geometric and linear material corrections of this theory render the matter content of the wormhole remarkably able to obey the energy conditions. (orig.)

  12. Existence of relativistic stars in f(R) gravity

    International Nuclear Information System (INIS)

    Upadhye, Amol; Hu, Wayne

    2009-01-01

    We refute recent claims in the literature that stars with relativistically deep potentials cannot exist in f(R) gravity. Numerical examples of stable stars, including relativistic (GM * /r * ∼0.1), constant density stars, are studied. As a star is made larger, nonlinear 'chameleon' effects screen much of the star's mass, stabilizing gravity at the stellar center. Furthermore, we show that the onset of this chameleon screening is unrelated to strong gravity. At large central pressures P>ρ/3, f(R) gravity, like general relativity, does have a maximum gravitational potential, but at a slightly smaller value: GM * /r * | max =0.345<4/9 for constant density and one choice of parameters. This difference is associated with negative central curvature R under general relativity not being accessed in the f(R) model, but does not apply to any known astrophysical object.

  13. Dynamic MR imaging of the musculoskeletal system

    International Nuclear Information System (INIS)

    Shah, A.S.; Hylton, H.; Hentz, V.R.; Schattner, P.

    1991-01-01

    This paper reports on dynamic MR imaging which is an MR technique that allows imaging of the musculoskeletal system in motion. Current methods for observing the articulation of muscles and joints are limited to acquisition of stationary images at different spatial orientations. These images are then replayed from computer memory to simulate motion. Unlike stationary acquisition, dynamic MR imaging allows the volume of interest to be subjected to motion and dynamic stress, which is important for detecting stress-induced pathology. To demonstrate the utility of dynamic MR imaging, a system for imaging a moving wrist has been developed. The system consists of apparatus capable of providing simultaneous radialulnar deviation and flexion-extension, and hardware for system control and acquisition gating. The apparatus is mounted on the patient bed and is transferable to a variety of standard clinical MR imaging systems. Images were obtained during motion, and the ability of dynamic MR imaging to accurately image the moving wrist with very little motion artifact was demonstrated

  14. f(R) gravity: scalar perturbations in the late Universe

    Czech Academy of Sciences Publication Activity Database

    Eingorn, M.; Novák, Jan; Zhuk, A.

    2014-01-01

    Roč. 74, č. 8 (2014), s. 3005 ISSN 1434-6044 Institutional support: RVO:67985840 Keywords : nonlinear f(R) gravity * scalar cosmological perturbations * scalaron Subject RIV: BA - General Mathematics Impact factor: 5.084, year: 2014 http://link.springer.com/article/10.1140/epjc/s10052-014-3005-1

  15. Models of f(R) cosmic acceleration that evade solar system tests

    International Nuclear Information System (INIS)

    Hu, Wayne; Sawicki, Ignacy

    2007-01-01

    We study a class of metric-variation f(R) models that accelerates the expansion without a cosmological constant and satisfies both cosmological and solar-system tests in the small-field limit of the parameter space. Solar-system tests alone place only weak bounds on these models, since the additional scalar degree of freedom is locked to the high-curvature general-relativistic prediction across more than 25 orders of magnitude in density, out through the solar corona. This agreement requires that the galactic halo be of sufficient extent to maintain the galaxy at high curvature in the presence of the low-curvature cosmological background. If the galactic halo and local environment in f(R) models do not have substantially deeper potentials than expected in ΛCDM, then cosmological field amplitudes |f R | > or approx.10 -6 will cause the galactic interior to evolve to low curvature during the acceleration epoch. Viability of large-deviation models therefore rests on the structure and evolution of the galactic halo, requiring cosmological simulations of f(R) models, and not directly on solar-system tests. Even small deviations that conservatively satisfy both galactic and solar-system constraints can still be tested by future, percent-level measurements of the linear power spectrum, while they remain undetectable to cosmological-distance measures. Although we illustrate these effects in a specific class of models, the requirements on f(R) are phrased in a nearly model-independent manner

  16. Equivalence and precision of knee cartilage morphometry between different segmentation teams, cartilage regions, and MR acquisitions

    Science.gov (United States)

    Schneider, E; Nevitt, M; McCulloch, C; Cicuttini, FM; Duryea, J; Eckstein, F; Tamez-Pena, J

    2012-01-01

    Objective To compare precision and evaluate equivalence of femorotibial cartilage volume (VC) and mean cartilage thickness (ThCtAB.Me) from independent segmentation teams using identical MR images from three series: sagittal 3D Dual Echo in the Steady State (DESS), coronal multi-planar reformat (DESS-MPR) of DESS and coronal 3D Fast Low Angle SHot (FLASH). Design 19 subjects underwent test-retest MR imaging at 3 Tesla. Four teams segmented the cartilage using prospectively defined plate regions and rules. Mixed models analysis of the pooled data were used to evaluate the effect of acquisition, team and plate on precision and Pearson correlations and mixed models to evaluate equivalence. Results Segmentation team differences dominated measurement variability in most cartilage regions for all image series. Precision of VC and ThCtAB.Me differed significantly by team and cartilage plate, but not between FLASH and DESS. Mean values of VC and ThCtAB.Me differed by team (P<0.05) for DESS, FLASH and DESS-MPR, FLASH VC was 4–6% larger than DESS in the medial tibia and lateral central femur, and FLASH ThCtAB.Me was 5–6% larger in the medial tibia, but 4–8% smaller in the medial central femur. Correlations betweenDESS and FLASH for VC and ThCtAB.Me were high (r=0.90–0.97), except for DESS versus FLASH medial central femur ThCtAB.Me (r=0.81–0.83). Conclusions Cartilage morphology metrics from different image contrasts had similar precision, were generally equivalent, and may be combined for cross-sectional analyses if potential systematic offsets are accounted for. Data from different teams should not be pooled unless equivalence is demonstrated for cartilage metrics of interest. PMID:22521758

  17. f(R) gravity cosmology in scalar degree of freedom

    International Nuclear Information System (INIS)

    Goswami, Umananda Dev; Deka, Kabita

    2014-01-01

    The models of f(R) gravity belong to an important class of modified gravity models where the late time cosmic accelerated expansion is considered as the manifestation of the large scale modification of the force of gravity. f(R) gravity models can be expressed in terms of a scalar degree of freedom by explicit redefinition of model's variable. Here we report about the study of the features of cosmological parameters and hence the cosmological evolution using the scalar degree of freedom of the f(R) = ξR n gravity model in the Friedmann-Lemaître-Robertson-Walker (FLRW) background

  18. Robust sliding-window reconstruction for Accelerating the acquisition of MR fingerprinting.

    Science.gov (United States)

    Cao, Xiaozhi; Liao, Congyu; Wang, Zhixing; Chen, Ying; Ye, Huihui; He, Hongjian; Zhong, Jianhui

    2017-10-01

    To develop a method for accelerated and robust MR fingerprinting (MRF) with improved image reconstruction and parameter matching processes. A sliding-window (SW) strategy was applied to MRF, in which signal and dictionary matching was conducted between fingerprints consisting of mixed-contrast image series reconstructed from consecutive data frames segmented by a sliding window, and a precalculated mixed-contrast dictionary. The effectiveness and performance of this new method, dubbed SW-MRF, was evaluated in both phantom and in vivo. Error quantifications were conducted on results obtained with various settings of SW reconstruction parameters. Compared with the original MRF strategy, the results of both phantom and in vivo experiments demonstrate that the proposed SW-MRF strategy either provided similar accuracy with reduced acquisition time, or improved accuracy with equal acquisition time. Parametric maps of T 1 , T 2 , and proton density of comparable quality could be achieved with a two-fold or more reduction in acquisition time. The effect of sliding-window width on dictionary sensitivity was also estimated. The novel SW-MRF recovers high quality image frames from highly undersampled MRF data, which enables more robust dictionary matching with reduced numbers of data frames. This time efficiency may facilitate MRF applications in time-critical clinical settings. Magn Reson Med 78:1579-1588, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  19. 78 FR 29247 - Contractor Legal Management Requirements; Acquisition Regulations; Correction

    Science.gov (United States)

    2013-05-20

    ... DEPARTMENT OF ENERGY 48 CFR Part 952 RIN 1990-AA37 Contractor Legal Management Requirements; Acquisition Regulations; Correction AGENCY: Department of Energy. ACTION: Final rule; correction. SUMMARY: The... (78 FR 25795). In this document, DOE revised existing regulations covering contractor legal management...

  20. Constraint propagation equations of the 3+1 decomposition of f(R) gravity

    International Nuclear Information System (INIS)

    Paschalidis, Vasileios; Shapiro, Stuart L; Halataei, Seyyed M H; Sawicki, Ignacy

    2011-01-01

    Theories of gravity other than general relativity (GR) can explain the observed cosmic acceleration without a cosmological constant. One such class of theories of gravity is f(R). Metric f(R) theories have been proven to be equivalent to Brans-Dicke (BD) scalar-tensor gravity without a kinetic term (ω = 0). Using this equivalence and a 3+1 decomposition of the theory, it has been shown that metric f(R) gravity admits a well-posed initial value problem. However, it has not been proven that the 3+1 evolution equations of metric f(R) gravity preserve the (Hamiltonian and momentum) constraints. In this paper, we show that this is indeed the case. In addition, we show that the mathematical form of the constraint propagation equations in BD-equilavent f(R) gravity and in f(R) gravity in both the Jordan and Einstein frames is exactly the same as in the standard ADM 3+1 decomposition of GR. Finally, we point out that current numerical relativity codes can incorporate the 3+1 evolution equations of metric f(R) gravity by modifying the stress-energy tensor and adding an additional scalar field evolution equation. We hope that this work will serve as a starting point for relativists to develop fully dynamical codes for valid f(R) models.

  1. MR Imaging-derived Oxygen-Hemoglobin Dissociation Curves and Fetal-Placental Oxygen-Hemoglobin Affinities.

    Science.gov (United States)

    Avni, Reut; Golani, Ofra; Akselrod-Ballin, Ayelet; Cohen, Yonni; Biton, Inbal; Garbow, Joel R; Neeman, Michal

    2016-07-01

    Purpose To generate magnetic resonance (MR) imaging-derived, oxygen-hemoglobin dissociation curves and to map fetal-placental oxygen-hemoglobin affinity in pregnant mice noninvasively by combining blood oxygen level-dependent (BOLD) T2* and oxygen-weighted T1 contrast mechanisms under different respiration challenges. Materials and Methods All procedures were approved by the Weizmann Institutional Animal Care and Use Committee. Pregnant mice were analyzed with MR imaging at 9.4 T on embryonic days 14.5 (eight dams and 58 fetuses; imprinting control region ICR strain) and 17.5 (21 dams and 158 fetuses) under respiration challenges ranging from hyperoxia to hypoxia (10 levels of oxygenation, 100%-10%; total imaging time, 100 minutes). A shorter protocol with normoxia to hyperoxia was also performed (five levels of oxygenation, 20%-100%; total imaging time, 60 minutes). Fast spin-echo anatomic images were obtained, followed by sequential acquisition of three-dimensional gradient-echo T2*- and T1-weighted images. Automated registration was applied to align regions of interest of the entire placenta, fetal liver, and maternal liver. Results were compared by using a two-tailed unpaired Student t test. R1 and R2* values were derived for each tissue. MR imaging-based oxygen-hemoglobin dissociation curves were constructed by nonlinear least square fitting of 1 minus the change in R2*divided by R2*at baseline as a function of R1 to a sigmoid-shaped curve. The apparent P50 (oxygen tension at which hemoglobin is 50% saturated) value was derived from the curves, calculated as the R1 scaled value (x) at which the change in R2* divided by R2*at baseline scaled (y) equals 0.5. Results The apparent P50 values were significantly lower in fetal liver than in maternal liver for both gestation stages (day 14.5: 21% ± 5 [P = .04] and day 17.5: 41% ± 7 [P hemoglobin dissociation curves with a shorter protocol that excluded the hypoxic periods was demonstrated. Conclusion MR imaging

  2. Dynamic MR-mammography in invasive lobular breast cancer; Dynamische MR-Mammographie beim invasiv lobulaeren Mammakarzinom bei 1,0 T

    Energy Technology Data Exchange (ETDEWEB)

    Sittek, H.; Perlet, C.; Kessler, M.; Reiser, M. [Institut fuer Radiologische Diagnostik, Klinikum Grossenhadern, Ludwig-Maximilians-Univ., Muenchen (Germany); Untch, M. [Klinik und Poliklinik fuer Frauenheilkunde und Geburtshilfe, Klinikum Grossenhadern, Ludwig-Maximilians-Univ., Muenchen (Germany)

    1998-12-31

    Material and Methods: We carried out 1505 MR mammographoes in 1357 patients. Biopsy was indicated in 413 cases. Among the malignancies, 23/214 (10%) were ILC. MR-M was performed with a 1.0 T whole body MRI system with a dynamic FLASH-3D sequence. Relative signal enhancement within lesions detected and morphologic pattern of contrast enhancement (mep) were determined. Three types of mep were distinguished: type 1 without contrast enhancement, type 2 with focal contrast enhancement, and type 3 with diffuse contrast enhancement of the glandular body. Results: Within MR-M alone, 19/23 (82.6%) of ILC were detected due to a mep type 2. Four ILC were false negative on MR-M (2 cases show mep type 1 or mep type 3). The sensitivity of Mx alone was 86.9% (20/23). When both Mx and MR-M were combined, all 23 ILC were detected. The addition of MR-M to Mx may increase sensitivity to about 100% in the detection of ILC. (orig.) [Deutsch] Material und Methode: Im Zeitraum 05/1993 bis 06/1996 fuehrten wir bei 1357 Patientinnen 1505 MR-Mammographien durch. In 413 Faellen wurde eine Probeexzision indiziert. Die histologische Untersuchung ergab in 214 Faellen einen malignen Tumor. Darunter befanden sich 23 ILC. Die MR-M wurden an einem 1,0 T MRT-System (Impact, Siemens, Erlangen) mit einer dynamischen FLASH 3D Sequenz durchgefuehrt. Neben dem prozentualen Anstieg der Signalintensitaet innerhalb einer Laesion haben wir fuer die Diagnostik folgende morphologische Befundmuster (BM) unterschieden: Typ 1: Keine Aufnahme, Typ 2: Fokale Aufnahme, Typ 3: Diffuse Aufnahme des Druesenkoerpers in der MR-M. Ergebnisse: Mit der MR-M konnten 19/23 (82,6%) der ILC anhand einer fokalen Zunahme der Signalintensitaet richtig positiv erkannt werden (BM Typ 2). Vier der ILC waren in der MR-M falsch negativ. In zwei Faellen (2/23) war keine Zunahme der Signalintensitaet zu verzeichnen (BM Typ 1). In zwei weiteren Faellen (2/23) maskierte eine diffuse Signalintensitaetszunahme des Druesenkoerpers (BM Typ 3

  3. Diagnostic accuracy of dynamic contrast-enhanced MR imaging of renal masses with rapid-acquisition spin-echo technique

    International Nuclear Information System (INIS)

    Eilenberg, S.S.; Lee, J.K.T.; Brown, J.J.; Heiken, J.P.; Mirowitz, S.A.

    1990-01-01

    This paper compares the diagnostic accuracy of Gd-DTPA-enhanced rapid-acquisition spin-echo (RASE) imaging with standard spin-echo techniques for detecting renal cysts and solid renal neoplasms. RASE imaging combines a short TR (275 msec)/short TE (10 msec), single excitation pulse sequence with half-Fourier data sampling. Eighteen patients with CT evidence of renal masses were first evaluated with standard T1-and T2-weighted SE sequences. Pre- and serial postcontrast (Cd-DTPA, 0.1 mmol./kg) RASE sequences were then performed during suspended respiration. A final set of postcontrast images was obtained with the standard T1-weighted SE sequence. Each set of MR images was first reviewed separately (ie, T1, T2, pre- and post-contrast RASE, etc)

  4. Robust approach to f(R) gravity

    International Nuclear Information System (INIS)

    Jaime, Luisa G.; Patino, Leonardo; Salgado, Marcelo

    2011-01-01

    We consider metric f(R) theories of gravity without mapping them to their scalar-tensor counterpart, but using the Ricci scalar itself as an ''extra'' degree of freedom. This approach avoids then the introduction of a scalar-field potential that might be ill defined (not single valued). In order to explicitly show the usefulness of this method, we focus on static and spherically symmetric spacetimes and deal with the recent controversy about the existence of extended relativistic objects in certain class of f(R) models.

  5. Possible antigravity regions in F(R) theory?

    Energy Technology Data Exchange (ETDEWEB)

    Bamba, Kazuharu, E-mail: bamba@kmi.nagoya-u.ac.jp [Kobayashi-Maskawa Institute for the Origin of Particles and the Universe, Nagoya University, Nagoya 464-8602 (Japan); Nojiri, Shin' ichi, E-mail: nojiri@phys.nagoya-u.ac.jp [Kobayashi-Maskawa Institute for the Origin of Particles and the Universe, Nagoya University, Nagoya 464-8602 (Japan); Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Odintsov, Sergei D., E-mail: odintsov@ieec.uab.es [Department of Physics, Nagoya University, Nagoya 464-8602 (Japan); Instituciò Catalana de Recerca i Estudis Avançats (ICREA), Barcelona (Spain); Institut de Ciencies de l' Espai (CSIC-IEEC), Campus UAB, Facultat de Ciencies, Torre C5-Par-2a pl, E-08193 Bellaterra (Barcelona) (Spain); Tomsk State Pedagogical University, Kievskaya Avenue, 60, 634061, Tomsk (Russian Federation); Sáez-Gómez, Diego, E-mail: diego.saezgomez@uct.ac.za [Astrophysics, Cosmology and Gravity Centre (ACGC) and Department of Mathematics and Applied Mathematics, University of Cape Town, Rondebosch 7701, Cape Town (South Africa); Fisika Teorikoaren eta Zientziaren Historia Saila, Zientzia eta Teknologia Fakultatea, Euskal Herriko Unibertsitatea, 644 Posta Kutxatila, 48080 Bilbao (Spain)

    2014-03-07

    We construct an F(R) gravity theory corresponding to the Weyl invariant two scalar field theory. We investigate whether such F(R) gravity can have the antigravity regions where the Weyl curvature invariant does not diverge at the Big Bang and Big Crunch singularities. It is revealed that the divergence cannot be evaded completely but can be much milder than that in the original Weyl invariant two scalar field theory.

  6. Holographic dark energy and f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Aghamohammadi, A [Faculty of Science, Islamic Azad University of Sanandaj, Sanandaj (Iran, Islamic Republic of); Saaidi, Kh, E-mail: ksaaidi@uok.ac.ir, E-mail: agha35484@yahoo.com [Department of Physics, Faculty of Science, University of Kurdistan, Sanandaj (Iran, Islamic Republic of)

    2011-02-15

    We investigate the corresponding relation between f(R) gravity and holographic dark energy. We introduce a type of energy density from f(R) that has the same role as holographic dark energy. We obtain the differential equation that specifies the evolution of the introduced energy density parameter based on a varying gravitational constant. We discover the relation for the equation of state parameter for low redshifts that contains varying G correction.

  7. Possible antigravity regions in F(R) theory?

    Science.gov (United States)

    Bamba, Kazuharu; Nojiri, Shin'ichi; Odintsov, Sergei D.; Sáez-Gómez, Diego

    2014-03-01

    We construct an F(R) gravity theory corresponding to the Weyl invariant two scalar field theory. We investigate whether such F(R) gravity can have the antigravity regions where the Weyl curvature invariant does not diverge at the Big Bang and Big Crunch singularities. It is revealed that the divergence cannot be evaded completely but can be much milder than that in the original Weyl invariant two scalar field theory.

  8. Possible antigravity regions in F(R) theory?

    International Nuclear Information System (INIS)

    Bamba, Kazuharu; Nojiri, Shin'ichi; Odintsov, Sergei D.; Sáez-Gómez, Diego

    2014-01-01

    We construct an F(R) gravity theory corresponding to the Weyl invariant two scalar field theory. We investigate whether such F(R) gravity can have the antigravity regions where the Weyl curvature invariant does not diverge at the Big Bang and Big Crunch singularities. It is revealed that the divergence cannot be evaded completely but can be much milder than that in the original Weyl invariant two scalar field theory.

  9. f(R) constant-roll inflation

    Energy Technology Data Exchange (ETDEWEB)

    Motohashi, Hayato [Universidad de Valencia-CSIC, Instituto de Fisica Corpuscular (IFIC), Valencia (Spain); Starobinsky, Alexei A. [L.D. Landau Institute for Theoretical Physics, RAS, Moscow (Russian Federation); National Research University Higher School of Economics, Moscow (Russian Federation)

    2017-08-15

    The previously introduced class of two-parametric phenomenological inflationary models in general relativity in which the slow-roll assumption is replaced by the more general, constant-roll condition is generalized to the case of f(R) gravity. A simple constant-roll condition is defined in the original Jordan frame, and exact expressions for a scalaron potential in the Einstein frame, for a function f(R) (in the parametric form) and for inflationary dynamics are obtained. The region of the model parameters permitted by the latest observational constraints on the scalar spectral index and the tensor-to-scalar ratio of primordial metric perturbations generated during inflation is determined. (orig.)

  10. 77 FR 3636 - Federal Acquisition Regulation; Brand-Name Specifications; Correction

    Science.gov (United States)

    2012-01-25

    ... 26] RIN 9000-AK55 Federal Acquisition Regulation; Brand-Name Specifications; Correction AGENCY... Regulation (FAR) to implement the Office of Management and Budget memoranda on brand-name specifications, FAR Case 2005-037, Brand-Name Specifications, which published in the Federal Register at 77 FR 189 on...

  11. MR imaging of prostate. Preliminary experience with calculated imaging in 28 cases

    International Nuclear Information System (INIS)

    Gevenois, P.A.; Van Regemorter, G.; Ghysels, M.; Delepaut, A.; Van Gansbeke, D.; Struyven, J.

    1988-01-01

    The majority of studies with MR imaging in prostate disease are based on a semiology obtained using images weighted in T1 and T2. A study was carried out to evaluate effects of images calculated in T1 and T2 obtained at 0.5T. This preliminary study concerns 28 prostate examinations with spin-echo acquisition and inversion-recuperation parameters, and provided images calculated in T1, weighted and calculated in T2. Images allowed detection and characterization of prostate lesions. However, although calculated images accentuate discrimination of the method, the weighted images conserve their place because of their improved spatial resolution [fr

  12. 76 FR 14588 - Defense Federal Acquisition Regulation Supplement; Nonavailability Exception for Procurement of...

    Science.gov (United States)

    2011-03-17

    ... Federal Acquisition Regulation Supplement; Nonavailability Exception for Procurement of Hand or Measuring... Subjects in 48 CFR Part 225 Government procurement. Ynette R. Shelkin, Editor, Defense Acquisition... requirement at 10 U.S.C. 2533a (Berry Amendment) to acquire only domestic hand or measuring tools. DATES...

  13. 77 FR 70780 - Federal Acquisition Regulation; Submission for OMB Review; Contractors Performing Private...

    Science.gov (United States)

    2012-11-27

    ... business confidential information provided. FOR FURTHER INFORMATION CONTACT: Mr. Michael O. Jackson, Procurement Analyst, Governmentwide Acquisition Policy, at 202-208-4949 or email michaelo.jackson@gsa.gov...

  14. Functional evaluation of hydronephrosis by diffusion-weighted MR imaging: Relationship between apparent diffusion coefficient and split glomerular filtration rate

    International Nuclear Information System (INIS)

    Toyoshima, S.; Noguchi, K.; Seto, H.; Shimizu, M.; Watanabe, N.

    2000-01-01

    To determine the relationship between apparent diffusion coefficient (ADC) values measured by diffusion-weighted MR imaging and split renal function determined by renal scintigraphy in patients with hydronephrosis. Material and Methods: Diffusion-weighted imaging on a 1.5 T MR unit and renal scintigraphy were performed in 36 patients with hydronephrosis (45 hydronephrotic kidneys, 21 non-hydronephrotic kidneys). ADC values of the individual kidneys were measured by diffusion-weighted MR imaging. Split renal function (glomerular filtration rate (GFR)) was determined by renal scintigraphy using 99m Tc-DTPA. The relationship between ADC values and split GFR was examined in 66 kidneys. The hydronephrotic kidneys were further classified into three groups (severe renal dysfunction, GFR 25 ml/min, n=28), and mean values for ADCs were calculated. Results: In hydronephrotic kidneys, there was a moderate positive correlation between ADC values and split GFR (R2=0.56). On the other hand, in non-hydronephrotic kidneys, poor correlation between ADC values and split GFR was observed (R2=0.08). The mean values for ADCs of the dysfunctioning hydronephrotic kidneys (severe renal dysfunction, 1.32x10 -3 ±0.18x10 -3 mm 2 /s; moderate renal dysfunction, 1.38x10 -3 ±0.10x10 -3 mm2/s) were significantly lower than that of the normal functioning hydronephrotic kidneys (1.63x10 -3 ±0.12±10 -3 mm 2 /s). Conclusion: These results indicated that measurement of ADC values by diffusion-weighted MR imaging has a potential value in the evaluation of the functional status of hydronephrotic kidneys

  15. 77 FR 1656 - Proposed Establishment of Restricted Areas R-5402, R-5403A, R-5403B, R-5403C, R-5403D, R-5403E, R...

    Science.gov (United States)

    2012-01-11

    ...-0117; Airspace Docket No. 09-AGL-31] RIN 2120-AI92 Proposed Establishment of Restricted Areas R-5402, R-5403A, R- 5403B, R-5403C, R-5403D, R-5403E, R-5403F; Devils Lake, ND AGENCY: Federal Aviation... Restricted Areas R-5402, R-5403A, R-5403B, R- 5403C, R-5403D, R-5403E, R-5403F; Devils Lake, ND (76 FR 72869...

  16. 10 CFR 626.4 - General acquisition strategy.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false General acquisition strategy. 626.4 Section 626.4 Energy DEPARTMENT OF ENERGY (CONTINUED) SALES REGULATION PROCEDURES FOR ACQUISITION OF PETROLEUM FOR THE STRATEGIC PETROLEUM RESERVE § 626.4 General acquisition strategy. (a) Criteria for commencing acquisition. To reduce...

  17. 75 FR 54524 - Defense Federal Acquisition Regulation Supplement; Acquisition Strategies To Ensure Competition...

    Science.gov (United States)

    2010-09-08

    ...., because the changes are to internal Government organization and operating procedures only. The rule... 48 CFR Part 207 Government procurement. Ynette R. Shelkin, Editor, Defense Acquisition Regulations... Life Cycle of Major Defense Acquisition Programs (DFARS Case 2009-D014) AGENCY: Defense Acquisition...

  18. Radial MR images of the knee

    International Nuclear Information System (INIS)

    Hewes, R.C.; Miller, T.R.

    1988-01-01

    To profile optimally each portion of the meniscus, the authors use the multiangle, multisection feature of a General Electric SIGNA 1.5-T imager to produce radial images centered on each meniscus. A total of 12-15 sections are imaged at 10 0 -15 0 intervals of each meniscus, yielding perpendicular images of the entire meniscus, comparable with the arthrographic tangential views. The authors review their technique and demonstrate correlation cases between the radial gradient recalled acquisition in a steady state sequences, sagittal and coronal MR images, and arthrograms. Radial images should be a routine part of knee MR imaging

  19. Stellar configurations in f(R) theories of gravity

    International Nuclear Information System (INIS)

    Henttunen, K.; Multamaeki, T.; Vilja, I.

    2008-01-01

    We study stellar configurations and the space-time around them in metric f(R) theories of gravity. In particular, we focus on the polytropic model of the Sun in two specific cases: the f(R)=R-μ 4 /R model and a model with a stabilizing higher order term f(R)=R-μ 4 /R+βR 3 /(3μ 4 ). We show how the stellar configuration in the f(R) theory can, by appropriate initial conditions, be selected to be equal to that described by the Lane-Emden equation and how a simple scaling relation exists between the solutions. We also derive the correct solution analytically near the center of the star in f(R) theory. Previous analytical and numerical results are confirmed, indicating that the space-time around the Sun is incompatible with solar system constraints in the f(R)=R-μ 4 /R model. Numerical work shows that stellar configurations, with a regular metric at the center, lead to γ PPN ≅1/2 outside the star for both models, i.e., the Schwarzschild-de Sitter space-time is not the correct vacuum solution for such configurations. This shows that even when one fine-tunes the initial conditions inside a star such that the mass of the effective scalar in the equivalent scalar-tensor theory is large, γ PPN is still 1/2 outside the star. Conversely, by selecting the Schwarzschild-de Sitter metric as the outside solution, or equivalently setting the mass of the effective scalar to be large outside the star, we find that the stellar configuration is unchanged but the metric is irregular at the center. The possibility of constructing a f(R) theory compatible with the solar system experiments and possible new constraints arising from the radius-mass relation of stellar objects is discussed

  20. Cosmological reconstruction of realistic modified F(R) gravities

    International Nuclear Information System (INIS)

    Nojiri, Shin'ichi; Odintsov, Sergei D.; Saez-Gomez, Diego

    2009-01-01

    The cosmological reconstruction scheme for modified F(R) gravity is developed in terms of e-folding (or, redshift). It is demonstrated how any FRW cosmology may emerge from specific F(R) theory. The specific examples of well-known cosmological evolution are reconstructed, including ΛCDM cosmology, deceleration with transition to phantom superacceleration era which may develop singularity or be transient. The application of this scheme to viable F(R) gravities unifying inflation with dark energy era is proposed. The additional reconstruction of such models leads to non-leading gravitational correction mainly relevant at the early/late universe and helping to pass the cosmological bounds (if necessary). It is also shown how cosmological reconstruction scheme may be generalized in the presence of scalar field.

  1. Cosmology of Horava-Lifshitz f(R) gravity

    International Nuclear Information System (INIS)

    Chakrabarti, Sayan K.; Sen, Anjan A.

    2011-08-01

    We discuss the cosmology of recently proposed Horava-Lifshitz f(R) gravity. In particular, we derive the modified Hubble equation that reduces to the standard HL gravity case in appropriate limit. We show how the bounce solutions in this theory are modified due to nonlinear effect of f(R) gravity. In addition we find that the solutions exist when the Universe can make turn around for large scale-factor. Therefore, in principle, the Universe in this set-up can show cyclic behavior. (orig.)

  2. Cosmology of Horava-Lifshitz f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Chakrabarti, Sayan K. [Univ. Tecnica de Lisboa (Portugal). Inst. Superior Tecnico; Dutta, Koushik [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Sen, Anjan A. [Centre of Theoretical Physics, Jamia Millia Islamia, New Dehli (India)

    2011-08-15

    We discuss the cosmology of recently proposed Horava-Lifshitz f(R) gravity. In particular, we derive the modified Hubble equation that reduces to the standard HL gravity case in appropriate limit. We show how the bounce solutions in this theory are modified due to nonlinear effect of f(R) gravity. In addition we find that the solutions exist when the Universe can make turn around for large scale-factor. Therefore, in principle, the Universe in this set-up can show cyclic behavior. (orig.)

  3. M-commerce

    DEFF Research Database (Denmark)

    Ulhøi, John Parm; Jørgensen, Frances

    2009-01-01

    r små og mellemstore virksomheder (SMVer [F1] ) vover sig ud i nye forretningsmuligheder, som baserer sig på mobile devices via trådløs kommunikation med et forretningsmæssigt formål for øje eller 'Mobile Commerce' (M-commerce), skal de være meget dygtige til både at udnytte forkantsteknologier...... af disse netværk som en central del af nye M-commerce forretningsmodeller for SMVer og at redegøre for de foreløbige resultater fra projektets indledende fase. Projektets formål er at udforske, beskrive og facilitere udviklingen af nye forretningsmodeller for M-commerce i danske SMVer. Data er blevet...... indsamlet gennem dybdeinterview. Artiklen bidrager til teori om M-commerce forretningsmodeller, og i særdeleshed, modeller der karakteriseres af intenst netværkssamarbejde.   [F1] Jeg er ikke overbevist, at vi ikke skulle bruge SMEs, da det er meget mere kendt, også herhjemme....

  4. Galaxy-galaxy weak gravitational lensing in f(R) gravity

    Science.gov (United States)

    Li, Baojiu; Shirasaki, Masato

    2018-03-01

    We present an analysis of galaxy-galaxy weak gravitational lensing (GGL) in chameleon f(R) gravity - a leading candidate of non-standard gravity models. For the analysis, we have created mock galaxy catalogues based on dark matter haloes from two sets of numerical simulations, using a halo occupation distribution (HOD) prescription which allows a redshift dependence of galaxy number density. To make a fairer comparison between the f(R) and Λ cold dark matter (ΛCDM) models, their HOD parameters are tuned so that the galaxy two-point correlation functions in real space (and therefore the projected two-point correlation functions) match. While the f(R) model predicts an enhancement of the convergence power spectrum by up to ˜ 30 per cent compared to the standard ΛCDM model with the same parameters, the maximum enhancement of GGL is only half as large and less than 5 per cent on separations above ˜1-2 h-1 Mpc, because the latter is a cross-correlation of shear (or matter, which is more strongly affected by modified gravity) and galaxy (which is weakly affected given the good match between galaxy autocorrelations in the two models) fields. We also study the possibility of reconstructing the matter power spectrum by combination of GGL and galaxy clustering in f(R) gravity. We find that the galaxy-matter cross-correlation coefficient remains at unity down to ˜2-3 h-1 Mpc at relevant redshifts even in f(R) gravity, indicating joint analysis of GGL and galaxy clustering can be a powerful probe of matter density fluctuations in chameleon gravity. The scale dependence of the model differences in their predictions of GGL can potentially allows us to break the degeneracy between f(R) gravity and other cosmological parameters such as Ωm and σ8.

  5. 76 FR 65183 - National Oceanic and Atmospheric Administration

    Science.gov (United States)

    2011-10-20

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration National Climate Assessment... Oceanic and Atmospheric Administration (NOAA), Department of Commerce (DOC). ACTION: Notice of open..., National Oceanic and Atmospheric Administration. [FR Doc. 2011-27113 Filed 10-19-11; 8:45 am] BILLING CODE...

  6. 78 FR 17670 - Federal Acquisition Regulation; Information Collection; Right of First Refusal of Employment

    Science.gov (United States)

    2013-03-22

    .... FOR FURTHER INFORMATION CONTACT: Mr. Michael O. Jackson, Procurement Analyst, Office of Governmentwide Acquisition Policy GSA, at (202) 208- 4949 or via email at michaelo.jackson@gsa.gov . SUPPLEMENTARY...

  7. Temperature, salinity and other variables collected from discrete sample and profile observations using CTD, bottle and other instruments from the NEW HORIZON in the North Pacific Ocean from 1980-08-10 to 1980-09-03 (NODC Accession 0116707)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NODC Accession 0116707 includes chemical, discrete sample, physical and profile data collected from NEW HORIZON in the North Pacific Ocean from 1980-08-10 to...

  8. Late-time cosmological approach in mimetic f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Baffou, E.H. [Institut de Mathematiques et de Sciences Physiques (IMSP), Porto-Novo (Benin); Houndjo, M.J.S. [Institut de Mathematiques et de Sciences Physiques (IMSP), Porto-Novo (Benin); Faculte des Sciences et Techniques de Natitingou, Natitingou (Benin); Hamani-Daouda, M. [Universite de Niamey, Departement de Physique, Niamey (Niger); Alvarenga, F.G. [Universidade Federal do Espirito Santo, Departamento de Engenharia e Ciencias Naturais, CEUNES, Sao Mateus, ES (Brazil)

    2017-10-15

    In this paper, we investigate the late-time cosmic acceleration in mimetic f(R, T) gravity with the Lagrange multiplier and potential in a Universe containing, besides radiation and dark energy, a self-interacting (collisional) matter. We obtain through the modified Friedmann equations the main equation that can describe the cosmological evolution. Then, with several models from Q(z) and the well-known particular model f(R, T), we perform an analysis of the late-time evolution. We examine the behavior of the Hubble parameter, the dark energy equation of state and the total effective equation of state and in each case we compare the resulting picture with the non-collisional matter (assumed as dust) and also with the collisional matter in mimetic f(R, T) gravity. The results obtained are in good agreement with the observational data and show that in the presence of the collisional matter the dark energy oscillations in mimetic f(R, T) gravity can be damped. (orig.)

  9. 78 FR 15935 - Information Collection Requirement; Defense Federal Acquisition Regulation Supplement (DFARS...

    Science.gov (United States)

    2013-03-13

    ... automated collection techniques or other forms of information technology. The Office of Management and... construction contract in Spain has adequate insurance coverage. Affected Public: Businesses or other for profit... construction contract in Spain. Kortnee Stewart, Editor, Defense Acquisition Regulations System. [FR Doc. 2013...

  10. Generation of spherically symmetric metrics in f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Amirabi, Z.; Halilsoy, M.; Mazharimousavi, S.H. [Eastern Mediterranean University, Department of Physics, Gazimagusa (Turkey)

    2016-06-15

    In D-dimensional spherically symmetric f(R) gravity there are three unknown functions to be determined from the fourth order differential equations. It is shown that the system remarkably may be integrated to relate two functions through the third one to provide a reduction to second order equations accompanied with a large class of potential solutions. The third function, which acts as the generator of the process, is F(R) = (df(R))/(dR). We recall that our generating function has been employed as a scalar field with an accompanying self-interacting potential previously, which is entirely different from our approach. Reduction of f(R) theory into a system of equations seems to be efficient enough to generate a solution corresponding to each generating function. As particular examples, besides the known ones, we obtain new black hole solutions in any dimension D. We further extend our analysis to cover non-zero energy-momentum tensors. Global monopole and Maxwell sources are given as examples. (orig.)

  11. Rational approximations of f(R) cosmography through Pad'e polynomials

    Science.gov (United States)

    Capozziello, Salvatore; D'Agostino, Rocco; Luongo, Orlando

    2018-05-01

    We consider high-redshift f(R) cosmography adopting the technique of polynomial reconstruction. In lieu of considering Taylor treatments, which turn out to be non-predictive as soon as z>1, we take into account the Pad&apose rational approximations which consist in performing expansions converging at high redshift domains. Particularly, our strategy is to reconstruct f(z) functions first, assuming the Ricci scalar to be invertible with respect to the redshift z. Having the so-obtained f(z) functions, we invert them and we easily obtain the corresponding f(R) terms. We minimize error propagation, assuming no errors upon redshift data. The treatment we follow naturally leads to evaluating curvature pressure, density and equation of state, characterizing the universe evolution at redshift much higher than standard cosmographic approaches. We therefore match these outcomes with small redshift constraints got by framing the f(R) cosmology through Taylor series around 0zsimeq . This gives rise to a calibration procedure with small redshift that enables the definitions of polynomial approximations up to zsimeq 10. Last but not least, we show discrepancies with the standard cosmological model which go towards an extension of the ΛCDM paradigm, indicating an effective dark energy term evolving in time. We finally describe the evolution of our effective dark energy term by means of basic techniques of data mining.

  12. F(R Gravity’s Rainbow and Its Einstein Counterpart

    Directory of Open Access Journals (Sweden)

    S. H. Hendi

    2016-01-01

    Full Text Available Motivated by UV completion of general relativity with a modification of a geometry at high energy scale, it is expected to have an energy dependent geometry. In this paper, we introduce charged black hole solutions with power Maxwell invariant source in the context of gravity’s rainbow. In addition, we investigate two classes of F(R gravity’s rainbow solutions. At first, we study energy dependent F(R gravity without energy-momentum tensor, and then we obtain F(R gravity’s rainbow in the presence of conformally invariant Maxwell source. We study geometrical properties of the mentioned solutions and compare their results. We also give some related comments regarding thermodynamical behavior of the obtained solutions and discuss thermal stability of the solutions.

  13. Exploring the liminality: properties of haloes and subhaloes in borderline f(R) gravity

    Science.gov (United States)

    Shi, Difu; Li, Baojiu; Han, Jiaxin; Gao, Liang; Hellwing, Wojciech A.

    2015-09-01

    We investigate the properties of dark matter haloes and subhaloes in an f(R) gravity model with |fR0| = 10-6, using a very-high-resolution N-body simulation. The model is a borderline between being cosmologically interesting and yet still consistent with current data. We find that the halo mass function in this model has a maximum 20 per cent enhancement compared with the Λ-cold-dark-matter (ΛCDM) predictions between z = 1 and 0. Because of the chameleon mechanism which screens the deviation from standard gravity in dense environments, haloes more massive than 1013 h-1 M⊙ in this f(R) model have very similar properties to haloes of similar mass in ΛCDM, while less massive haloes, such as that of the Milky Way, can have steeper inner density profiles and higher velocity dispersions due to their weaker screening. The halo concentration is remarkably enhanced for low-mass haloes in this model due to a deepening of the total gravitational potential. Contrary to the naive expectation, the halo formation time zf is later for low-mass haloes in this model, a consequence of these haloes growing faster than their counterparts in ΛCDM at late times and the definition of zf. Subhaloes, especially those less massive than 1011 h-1 M⊙, are substantially more abundant in this f(R) model for host haloes less massive than 1013 h-1 M⊙. We discuss the implications of these results for the Milky Way satellite abundance problem. Although the overall halo and subhalo properties in this borderline f(R) model are close to their ΛCDM predictions, our results suggest that studies of the Local Group and astrophysical systems, aided by high-resolution simulations, can be valuable for further tests of it.

  14. 75 FR 63813 - Membership of the Bureau Industry Security Performance Review Board

    Science.gov (United States)

    2010-10-18

    ..., Department of Commerce Human Resources Operations Center (DOCHROC), Office of Executive Resources Operations... Administration. Susan Boggs, Director, Office of Staffing, Recruitment and Classification, Department of Commerce Human Resources Operations Center. [FR Doc. 2010-26168 Filed 10-15-10; 8:45 am] BILLING CODE 3510-25-P ...

  15. 76 FR 81793 - The Commerce Control List

    Science.gov (United States)

    2011-12-29

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security 15 CFR Part 774 The Commerce Control List CFR Correction In Title 15 of the Code of Federal Regulations, Parts 300 to 799, revised as of Jan. 1... Commerce Control List), Category 9 Aerospace and Propulsion, Product Group E is amended by revising the...

  16. 78 FR 5449 - Federal Acquisition Regulation; Submission of OMB Review; Advance Payments

    Science.gov (United States)

    2013-01-25

    ...; Submission of OMB Review; Advance Payments AGENCIES: Department of Defense (DOD), General Services... requirement concerning advance payments. A notice was published in the Federal Register at 77 FR 43083, on... collection of information is necessary for the proper performance of functions of the Federal Acquisition...

  17. The holographic bound in the scalar-tensor and f(R) gravities

    International Nuclear Information System (INIS)

    Firouzjaee, J.T.

    2013-01-01

    The holographic bound has been extended to the different theory of gravities such as scalar-tensor gravity and f(R) gravity according to the Noether charge definition of the entropy for a black hole surface. We have introduced some popular examples of the flat FRW cosmology in order to investigate holographic bound in scalar-tensor and f(R) gravity. Using the holographic bound, we put an additional constraint on scalar-tensor gravity and the f(R) gravity parameters. We also discuss the transformation from Jordan frame to Einstein frame. (orig.)

  18. MR-Venography Using High Resolution True-FISP

    Energy Technology Data Exchange (ETDEWEB)

    Spuentrup, E. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Buecker, A.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Stuber, M. [Beth Israel Deaconess Medical Center, Boston, MA (United States). Dept. of Medicine; Harvard Medical School, Boston, MA (United States); Philips Med. Syst., Best (Netherlands)

    2001-08-01

    A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by X-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-veography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis. (orig.) [German] Eine neue schnelle, oertlich hochaufgeloeste MR-Phlebographietechnik mit einer axialen True-FISP Bildgebungssequenz wurde an 20 Patienten mit 23 nach-gewiesenen tiefen Beinvenenthrombosen untersucht. Die Befunde wurden mit einer konventionellen Roentgenphlebographie, einer CT oder einer Sonographie gesichert. Die vorgestellte Technik erlaubte in allen Faellen eine Thrombusdarstellung mit hohem Kontrast zum umgebenden venoesen Blut, wobei aufgrund der hohen Ortsaufloesung auch die Unterschenkelvenen beurteilt werden konnten. Die Datenaufnahmezeit zur Untersuchung des Beckens und der Beine betrug weniger als 10 Minuten. Kontrastmittel wurde nicht benoetigt. Die vorgestellte MR-Phlebographietechnik unter Verwendung einer oertlich hochauf-geloesten True-FISP Sequenz ist eine neue, vielversprechende, nicht-invasive Technik zur Diagnostik der tiefen Bein- und Beckenvenenthrombose. (orig.)

  19. 75 FR 44759 - Department of Commerce Business Forum

    Science.gov (United States)

    2010-07-29

    ... DEPARTMENT OF COMMERCE Department of Commerce Business Forum AGENCY: U.S. Department of Commerce... Commerce (DOC) is seeking vendors that currently conduct business with, or have previously conducted business with or hope to conduct business with DOC. Interested parties are asked to offer comments on the...

  20. Le developpement de Limacella glioderma (Fr.) R. Maire

    NARCIS (Netherlands)

    Reijnders, A.F.M.

    1979-01-01

    A comparison of the development of Limacella guttata (Fr.) Konrad & Maublanc with that of L. glioderma (Fr.) R. Maire shows clearly that the latter is of a more primitive type. This conclusion is based on the following observations: a. Limacella guttata has a pileocarpic development: the first

  1. Mr imaging and mr spectroscopy of brain metastases by mr perfusion

    International Nuclear Information System (INIS)

    Weber, Marc-Andre; Lichy, M.P.; Thilmann, C.; Guenther, M.; Bachert, P.; Delorme, S.; Schad, L.R.; Debus, J.; Schlemmer, H.P.; Maudsley, A.A.

    2003-01-01

    In follow-up examinations of irradiated brain metastases conventional contrast-enhanced morphological MR imaging is often unable to distinguish between transient radiation effects, radionecrosis, and tumor recurrence. To evaluate changes of relative cerebral blood flow (rCBF) in irradiated brain metastases arterial spin-labeling techniques (ASL) were applied and compared to the outcome of 1 H MR spectroscopy and spectroscopic imaging ( 1 H MRS, SI). Patients and methods In 2 patients follow-up examinations of irradiated brain metastases were performed on a 1.5-T tomograph (average single dose: 20 Gy/80% isodose). Relative CBF values of gray matter (GM), white matter (WM), and metastases (Met) were measured by means of the ASL techniques ITS-FAIR and Q2TIPS. 1 H MRS was performed with PRESS 1500/135. In both patients with initially hyperperfused metastases (Met/GM >1) the reduction of rCBF after stereotactic radiosurgery indicated response to treatment - even if the contrast-enhancing region increased - while increasing rCBF values indicated tumor progression. The findings were confirmed by 1 H MRS, SI and subsequent follow-up. The ASL techniques ITS-FAIR and Q2TIPS are able to monitor changes of rCBF in irradiated brain metastases. The two cases imply a possible role for ASL-MR perfusion imaging and 1 H MR spectroscopy in differentiating radiation effects from tumor progression. (orig.) [de

  2. Perfusion MR imaging for differentiation of benign and malignant meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [University of Groningen, Department of Radiology, University Medical Center Groningen, Groningen (Netherlands); Shanghai Jiaotong University, Department of Radiology, First People' s Hospital, Shanghai (China); Roediger, Lars A.; Oudkerk, Matthijs [University of Groningen, Department of Radiology, University Medical Center Groningen, Groningen (Netherlands); Shen, Tianzhen [Fudan University, Department of Radiology, Huashan Hospital, Shanghai (China); Miao, Jingtao [Shanghai Jiaotong University, Department of Radiology, First People' s Hospital, Shanghai (China)

    2008-06-15

    Our purpose was to determine whether perfusion MR imaging can be used to differentiate benign and malignant meningiomas on the basis of the differences in perfusion of tumor parenchyma and/or peritumoral edema. A total of 33 patients with preoperative meningiomas (25 benign and 8 malignant) underwent conventional and dynamic susceptibility contrast perfusion MR imaging. Maximal relative cerebral blood volume (rCBV) and the corresponding relative mean time to enhance (rMTE) (relative to the contralateral normal white matter) in both tumor parenchyma and peritumoral edema were measured. The independent samples t-test was used to determine whether there was a statistically significant difference in the mean rCBV and rMTE ratios between benign and malignant meningiomas. The mean maximal rCBV values of benign and malignant meningiomas were 7.16{+-}4.08 (mean{+-}SD) and 5.89{+-}3.86, respectively, in the parenchyma, and 1.05{+-}0.96 and 3.82{+-}1.39, respectively, in the peritumoral edema. The mean rMTE values were 1.16{+-}0.24 and 1.30{+-}0.32, respectively, in the parenchyma, and 0.91{+-}0.25 and 1.24{+-}0.35, respectively, in the peritumoral edema. The differences in rCBV and rMTE values between benign and malignant meningiomas were not statistically significant (P>0.05) in the parenchyma, but both were statistically significant (P<0.05) in the peritumoral edema. Perfusion MR imaging can provide useful information on meningioma vascularity which is not available from conventional MRI. Measurement of maximal rCBV and corresponding rMTE values in the peritumoral edema is useful in the preoperative differentiation between benign and malignant meningiomas. (orig.)

  3. Indirect MR arthrography in the evaluation of tears of the glenoid labrum; Indirekte MR-Arthrographie in der Diagnostik von Laesionen des Labrum glenoidale

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, T.; Vahlensieck, M.; Lutterbey, G.; Pauleit, D.; Kreft, B.; Keller, E.; Schild, H. [Radiologische Universitaetsklinik Bonn (Germany); Wallny, T. [Orthopaedische Universitaetsklinik Bonn (Germany); Steuer, K.; Golombek, V. [Klinik fuer Unfallchirurgie, Univ. Bonn (Germany)

    1997-07-01

    Purpose: It has been shown that intravenous administration of contrast media produces an MR arthrographic effect without the need for intraarticular injection. This is the first study evaluating this new technique of indirect MR arthrography in the diagnosis of glenoid labrum tears. Methods: 28 patients with clinically suspected labral injuries were prospectively investigated (1.5 Tesla, flexible surface coil). A plain MR examination of the shoulder (transverse and oblique-coronal orientation, T{sub 1}-weighted spin- [T{sub E}/T{sub R} 15/675], proton density- and T{sub 2}*-weighted gradient echo [T{sub E}/T{sub R}/Flip 14,32/600/30 ] sequences) and indirect MR arthrography (transverse and oblique-coronal orientation, fat-suppressed T{sub 1}-weighted spin-echo sequences [T{sub E}/T{sub R} 15/675], intravenous injection of gadopentetate dimeglumine [0.1 mmol/kg], followed by 10-15 min of joint movement) were performed. Results were confirmed by arthroscopy and/or open surgery. Results: Indirect MR arthrography significantly improved delineation of the glenoid labrum and hyaline cartilage (p<0.05). Sensitivity and specificity of indirect MR arthrography in the diagnosis of labral injuries were 90% and 89%, compared to 79% and 67% of the native MR examination. Conclusion: Indirect MR arthrography is a promising non-invasive technique in the evaluation of the glenoid labrum. (orig.) [Deutsch] Ziel: In frueheren Studien wurde gezeigt, dass die intravenoese Injektion gadoliniumhaltiger Kontrastmittel zur Signalintensitaetssteigerung im Gelenkkavum fuehrt. In dieser Studie wurde erstmals diese Technik der indirekten MR-Arthrographie am Schultergelenk in der Diagnostik von Labrumlaesionen evaluiert. Methode: 28 Patienten mit klinischem Verdacht auf eine Verletzung des Labrum glenoidale und/oder der Rotatorenmanschette wurden prospektiv nach folgendem Protokoll an einem 1,5-Tesla-System mit einer Oberflaechen-Ringspule untersucht: 1. Native MR-Standard-Untersuchung mit

  4. Chemical, physical and profile oceanographic data collected aboard NOAA Ship HENRY B. BIGELOW in the Gulf of Mexico from 2010-07-28 to 2010-08-10 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069091)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical and profile oceanographic data were collected aboard NOAA Ship HENRY B. BIGELOW in the Gulf of Mexico from 2010-07-28 to 2010-08-10 in response to...

  5. Intégration régionale, commerce et essor du secteur privé (Namibie ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Intégration régionale, commerce et essor du secteur privé (Namibie). La Namibie aspire à atteindre un niveau de vie comparable à celui des pays développés d'ici 2030. Le Namibian Economic Policy Research Unit (NEPRU), le principal institut de recherche sur la politique économique du pays, a pour mandat d'aider le ...

  6. Propagating Degrees of Freedom in f(R Gravity

    Directory of Open Access Journals (Sweden)

    Yun Soo Myung

    2016-01-01

    Full Text Available We have computed the number of polarization modes of gravitational waves propagating in the Minkowski background in f(R gravity. These are three of two from transverse-traceless tensor modes and one from a massive trace mode, which confirms the results found in the literature. There is no massless breathing mode and the massive trace mode corresponds to the Ricci scalar. A newly defined metric tensor in f(R gravity satisfies the transverse-traceless (TT condition as well as the TT wave equation.

  7. The coincidence problem in holographic f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Bisabr, Yousef, E-mail: y-bisabr@srttu.edu [Department of Physics, Shahid Rajaee Teacher Training University, Lavizan, Tehran 16788 (Iran, Islamic Republic of)

    2011-09-15

    It is well known that f(R) gravity models formulated in the Einstein conformal frame are equivalent to Einstein gravity together with a minimally coupled scalar field. In this case, the scalar field couples with the matter sector and the coupling term is given by the conformal factor. We apply the holographic principle to such interacting models. In a spatially flat universe, we show that the Einstein frame representation of f(R) models leads to a constant ratio of energy densities of dark matter to dark energy.

  8. Waste Area Group 10, Operable Unit 10-08, Remedial Investigation/Feasibility Study Annual Status Report for Fiscal Year 2006

    Energy Technology Data Exchange (ETDEWEB)

    R. P. Wells

    2007-05-09

    This report provides a status of the progress made in Fiscal Year 2006 on tasks identified in the Waste Area Group 10, Operable Unit 10-08, Remedial Investigation/Feasibility Study Work Plan. Major accomplishments include: (1) groundwater sampling and review of the groundwater monitoring data, (2) installation of a Sitewide groundwater-level monitoring network, (3) update of the Groundwater Monitoring and Field Sampling Plan of Operable Unit 10-08, (4) re-evaluation of the risk at Site TSF-08, (5) progress on the Operable Unit 10-08 Sitewide Groundwater Model.

  9. Late-time cosmological evolution of a general class of f(R, T) gravity with minimal curvature-matter coupling

    Energy Technology Data Exchange (ETDEWEB)

    Shabani, Hamid [University of Sistan and Baluchestan, Physics Department, Faculty of Sciences, Zahedan (Iran, Islamic Republic of); Ziaie, Amir Hadi [Islamic Azad University, Department of Physics, Kahnooj Branch, Kerman (Iran, Islamic Republic of)

    2017-08-15

    In this work, we study the late-time cosmological solutions of f(R, T) = g(R) + h(-T) models assuming that the conservation of the energy-momentum tensor (EMT) is violated. We perform our analysis through constructing an autonomous dynamical system for the equations of motion. We study the stability properties of solutions via considering linear perturbations about the related equilibrium points. Moreover, we parameterize the Lagrangian by introducing the parameters m(r) and n(s). These parameters which are constructed out of the functions g(R) and h(-T) play the main role in finding the late-time behavior of the solutions. We find that there exist, in general, three classes of solutions; all models with n > 0 include a proper transition from a prolonged matter era to a de Sitter solution. Models with -0.5 < n < 0 and n{sup '} > 1, for at least a root of equation n(s) = s - 1, include an unphysical dark energy solution preceding an improper matter era. Finally, for n < -1/2 there is a transient accelerated expansion era with -1/2 < w{sup (eff)} < -1/3 before a de Sitter phase. For all cases, in order to have a long enough matter dominated epoch, the condition m{sup '} → 0{sup +} for r f(R, T) = R{sup β} + (-T){sup α} can be observationally motivating for m → 0{sup +} and -0.024 < α < 0.02 and therefore could provide a suitable setting for later investigations. (orig.)

  10. Distinguishing f(R) theories from general relativity by gravitational lensing effect

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hongguang [Beijing Normal University, Department of Physics, Beijing (China); Aix Marseille Universite et Universite de Toulon, Centre de Physique Theorique (UMR 7332), Marseille (France); Wang, Xin; Li, Haida; Ma, Yongge [Beijing Normal University, Department of Physics, Beijing (China)

    2017-11-15

    The post-Newtonian formulation of a general class of f(R) theories is set up in a third-order approximation. It turns out that the information of a specific form of f(R) gravity is encoded in the Yukawa potential, which is contained in the perturbative expansion of the metric components. Although the Yukawa potential is canceled in the second-order expression of the effective refraction index of light, detailed analysis shows that the difference of the lensing effect between the f(R) gravity and general relativity does appear at the third order when √(f''(0)/f{sup '}(0)) is larger than the distance d{sub 0} to the gravitational source. However, the difference between these two kinds of theories will disappear in the axially symmetric spacetime region. Therefore only in very rare case the f(R) theories are distinguishable from general relativity by gravitational lensing effect in a third-order post-Newtonian approximation. (orig.)

  11. Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition

    Science.gov (United States)

    Hamamura, Mark J.; Ha, Seunghoon; Roeck, Werner W.; Tugan Muftuler, L.; Wagenaar, Douglas J.; Meier, Dirk; Patt, Bradley E.; Nalcioglu, Orhan

    2010-03-01

    In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system. Various phantom experiments characterized the interaction between the SPECT and MRI hardware components. The metallic components of the SPECT hardware altered the B0 field and generated a non-uniform reduction in the signal-to-noise ratio (SNR) of the MR images. The presence of a magnetic field generated a position shift and resolution loss in the nuclear projection data. Various techniques were proposed to compensate for these adverse effects. Overall, our results demonstrate that accurate, simultaneous SPECT and MRI data acquisition is feasible, justifying the further development of MRSPECT for either small-animal imaging or whole-body human systems by using appropriate components.

  12. General proof of the entropy principle for self-gravitating fluid in f(R) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Xiongjun [Department of Physics and Key Laboratory of Low Dimensional Quantum Structures andQuantum Control of Ministry of Education, Hunan Normal University,Changsha, Hunan 410081 (China); Guo, Minyong [Department of Physics, Beijing Normal University,Beijing 100875 (China); Jing, Jiliang [Department of Physics and Key Laboratory of Low Dimensional Quantum Structures andQuantum Control of Ministry of Education, Hunan Normal University,Changsha, Hunan 410081 (China)

    2016-08-29

    The discussions on the connection between gravity and thermodynamics attract much attention recently. We consider a static self-gravitating perfect fluid system in f(R) gravity, which is an important theory could explain the accelerated expansion of the universe. We first show that the Tolman-Oppenheimer-Volkoff equation of f(R) theories can be obtained by thermodynamical method in spherical symmetric spacetime. Then we prove that the maximum entropy principle is also valid for f(R) gravity in general static spacetimes beyond spherical symmetry. The result shows that if the constraint equation is satisfied and the temperature of fluid obeys Tolmans law, the extrema of total entropy implies other components of gravitational equations. Conversely, if f(R) gravitational equation hold, the total entropy of the fluid should be extremum. Our work suggests a general and solid connection between f(R) gravity and thermodynamics.

  13. Bladder carcinoma. Apport MR imaging

    International Nuclear Information System (INIS)

    Roy, C.; Spittler, G.; Jacqmin, D.; Morel, M.

    1991-01-01

    Bladder carcinoma is the second most commun cause of urogenital tumor. It is suspected by abdominal ultrasound and prouved by cystoscopy with biopsy. At present, MR Imaging is the most accurate diagnostic modality for loco-regional staging. Urography is still useful to appreciate urinary tract [fr

  14. k-space sampling optimization for ultrashort TE imaging of cortical bone: Applications in radiation therapy planning and MR-based PET attenuation correction

    International Nuclear Information System (INIS)

    Hu, Lingzhi; Traughber, Melanie; Su, Kuan-Hao; Pereira, Gisele C.; Grover, Anu; Traughber, Bryan; Muzic, Raymond F. Jr.

    2014-01-01

    Purpose: The ultrashort echo-time (UTE) sequence is a promising MR pulse sequence for imaging cortical bone which is otherwise difficult to image using conventional MR sequences and also poses strong attenuation for photons in radiation therapy and PET imaging. The authors report here a systematic characterization of cortical bone signal decay and a scanning time optimization strategy for the UTE sequence through k-space undersampling, which can result in up to a 75% reduction in acquisition time. Using the undersampled UTE imaging sequence, the authors also attempted to quantitatively investigate the MR properties of cortical bone in healthy volunteers, thus demonstrating the feasibility of using such a technique for generating bone-enhanced images which can be used for radiation therapy planning and attenuation correction with PET/MR. Methods: An angularly undersampled, radially encoded UTE sequence was used for scanning the brains of healthy volunteers. Quantitative MR characterization of tissue properties, including water fraction and R2 ∗ = 1/T2 ∗ , was performed by analyzing the UTE images acquired at multiple echo times. The impact of different sampling rates was evaluated through systematic comparison of the MR image quality, bone-enhanced image quality, image noise, water fraction, and R2 ∗ of cortical bone. Results: A reduced angular sampling rate of the UTE trajectory achieves acquisition durations in proportion to the sampling rate and in as short as 25% of the time required for full sampling using a standard Cartesian acquisition, while preserving unique MR contrast within the skull at the cost of a minimal increase in noise level. The R2 ∗ of human skull was measured as 0.2–0.3 ms −1 depending on the specific region, which is more than ten times greater than the R2 ∗ of soft tissue. The water fraction in human skull was measured to be 60%–80%, which is significantly less than the >90% water fraction in brain. High-quality, bone

  15. Thermodynamic laws for generalized f(R) gravity with curvature-matter coupling

    International Nuclear Information System (INIS)

    Wu Yabo; Zhao Yueyue; Cai Ronggen; Lu Jianbo; Lu Junwang; Gao Xiaojing

    2012-01-01

    The first law and the generalized second law (GSL) of thermodynamics for the generalized f(R) gravity with curvature-matter coupling are studied in the spatially homogeneous, isotropic FRW universe. The research results show that the field equations of the generalized f(R) gravity with curvature-matter coupling can be cast to the form of the first law of thermodynamics with the so-called the entropy production terms dS ¯ and the GSL can be given by considering the FRW universe filled only with ordinary matter enclosed by the dynamical apparent horizon with the Hawking temperature. Furthermore, as a concrete example, by utilizing the GSL the constraints on the gravitational model with f 1 (R)=R+αR l and f 2 (R)=R m are also discussed. It is worth noting these results given by us are quite general and can degenerate to the ones in Einstein's general relativity and pure f(R) gravity with non-coupling and non-minimal coupling as special cases. Comparing with the case of Einstein's general relativity, the appearance of the entropy production term dS ¯ in the first law of thermodynamics demonstrates that the horizon thermodynamics is non-equilibrium one for generalized f(R) gravity with curvature-matter coupling, which is consistent with the arguments given in Akbar and Cai (2007) [13] and Eling et al. (2006) [18].

  16. Constraining f(R gravity in solar system, cosmology and binary pulsar systems

    Directory of Open Access Journals (Sweden)

    Tan Liu

    2018-02-01

    Full Text Available The f(R gravity can be cast into the form of a scalar–tensor theory, and scalar degree of freedom can be suppressed in high-density regions by the chameleon mechanism. In this article, for the general f(R gravity, using a scalar–tensor representation with the chameleon mechanism, we calculate the parametrized post-Newtonian parameters γ and β, the effective gravitational constant Geff, and the effective cosmological constant Λeff. In addition, for the general f(R gravity, we also calculate the rate of orbital period decay of the binary system due to gravitational radiation. Then we apply these results to specific f(R models (Hu–Sawicki model, Tsujikawa model and Starobinsky model and derive the constraints on the model parameters by combining the observations in solar system, cosmological scales and the binary systems.

  17. PET/MR Imaging in Gynecologic Oncology.

    Science.gov (United States)

    Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina

    2017-08-01

    MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A no-hair theorem for black holes in f(R) gravity

    Science.gov (United States)

    Cañate, Pedro

    2018-01-01

    In this work we present a no-hair theorem which discards the existence of four-dimensional asymptotically flat, static and spherically symmetric or stationary axisymmetric, non-trivial black holes in the frame of f(R) gravity under metric formalism. Here we show that our no-hair theorem also can discard asymptotic de Sitter stationary and axisymmetric non-trivial black holes. The novelty is that this no-hair theorem is built without resorting to known mapping between f(R) gravity and scalar–tensor theory. Thus, an advantage will be that our no-hair theorem applies as well to metric f(R) models that cannot be mapped to scalar–tensor theory.

  19. Patient-adapted reconstruction and acquisition dynamic imaging method (PARADIGM) for MRI

    International Nuclear Information System (INIS)

    Aggarwal, Nitin; Bresler, Yoram

    2008-01-01

    Dynamic magnetic resonance imaging (MRI) is a challenging problem because the MR data acquisition is often not fast enough to meet the combined spatial and temporal Nyquist sampling rate requirements. Current approaches to this problem include hardware-based acceleration of the acquisition, and model-based image reconstruction techniques. In this paper we propose an alternative approach, called PARADIGM, which adapts both the acquisition and reconstruction to the spatio-temporal characteristics of the imaged object. The approach is based on time-sequential sampling theory, addressing the problem of acquiring a spatio-temporal signal under the constraint that only a limited amount of data can be acquired at a time instant. PARADIGM identifies a model class for the particular imaged object using a scout MR scan or auxiliary data. This object-adapted model is then used to optimize MR data acquisition, such that the imaging constraints are met, acquisition speed requirements are minimized, essentially perfect reconstruction of any object in the model class is guaranteed, and the inverse problem of reconstructing the dynamic object has a condition number of one. We describe spatio-temporal object models for various dynamic imaging applications including cardiac imaging. We present the theory underlying PARADIGM and analyze its performance theoretically and numerically. We also propose a practical MR imaging scheme for 2D dynamic cardiac imaging based on the theory. For this application, PARADIGM is predicted to provide a 10–25 × acceleration compared to the optimal non-adaptive scheme. Finally we present generalized optimality criteria and extend the scheme to dynamic imaging with three spatial dimensions

  20. Extension of loop quantum gravity to f(R) theories.

    Science.gov (United States)

    Zhang, Xiangdong; Ma, Yongge

    2011-04-29

    The four-dimensional metric f(R) theories of gravity are cast into connection-dynamical formalism with real su(2) connections as configuration variables. Through this formalism, the classical metric f(R) theories are quantized by extending the loop quantization scheme of general relativity. Our results imply that the nonperturbative quantization procedure of loop quantum gravity is valid not only for general relativity but also for a rather general class of four-dimensional metric theories of gravity.

  1. 77 FR 66464 - Federal Acquisition Regulation; Submission for OMB Review; Value Engineering Requirements

    Science.gov (United States)

    2012-11-05

    ...; whether our estimate of the public burden of this collection of information is accurate, and based on... provided. FOR FURTHER INFORMATION CONTACT: Mr. Curtis E. Glover, Sr., Procurement Analyst, Contract Policy Division, GSA, (202) 501-1448 or email at [email protected] . A. Purpose Per Federal Acquisition...

  2. Fast MR arthrography using VIBE sequences to evaluate the rotator cuff

    Energy Technology Data Exchange (ETDEWEB)

    Vandevenne, Jan E. [Ziekenhuizen Oost-Limburg, Department of Radiology, Genk (Belgium); Universitair Ziekenhuis Antwerpen, University of Antwerp, Department of Radiology, Edegem (Belgium); Vanhoenacker, Filip; Parizel, Paul M. [Universitair Ziekenhuis Antwerpen, University of Antwerp, Department of Radiology, Edegem (Belgium); Mahachie John, Jestinah M. [University of Hasselt, Centre for Statistics, Diepenbeek (Belgium); Gelin, Geert [Ziekenhuizen Oost-Limburg, Department of Radiology, Genk (Belgium)

    2009-07-15

    The purpose of this paper was to evaluate if short volumetric interpolated breath-hold examination (VIBE) sequences can be used as a substitute for T1-weighted with fat saturation (T1-FS) sequences when performing magnetic resonance (MR) arthrography to diagnose rotator cuff tears. Eighty-two patients underwent direct MR arthrography of the shoulder joint using VIBE (acquisition time of 13 s) and T1-FS (acquisition time of 5 min) sequences in the axial and paracoronal plane on a 1.0-T MR unit. Two radiologists scored rotator cuff tendons on VIBE and T1-FS images separately as normal, small/large partial thickness and full thickness tears with or without geyser sign. T1-FS sequences were considered the gold standard. Surgical correlation was available in a small sample. Sensitivity, specificity, and positive and negative predictive values of VIBE were greater than 92% for large articular-sided partial thickness and full thickness tears. For detecting fraying and articular-sided small partial thickness tears, these parameters were 55%, 94%, 94%, and 57%, respectively. The simple kappa value was 0.76, and the weighted kappa value was 0.86 for agreement between T1-FS and VIBE scores. All large partial and full thickness tears at surgery were correctly diagnosed using VIBE or T1-FS MR images. Fast MR arthrography of the shoulder joint using VIBE sequences showed good concordance with the classically used T1-FS sequences for the appearance of the rotator cuff, in particular for large articular-sided partial thickness tears and for full thickness tears. Due to its very short acquisition time, VIBE may be especially useful when performing MR arthrography in claustrophobic patients or patients with a painful shoulder. (orig.)

  3. Turbidity, SOLAR RADIATION - ATMOSPHERIC and other data from NATHANIEL B. PALMER from 1996-10-08 to 1996-11-05 (NODC Accession 9900066)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature, salinity, and nutrients data were collected from CTD and bottle casts in the Pacific Ocean from the Nathaniel B. Palmer from 08 October 1996 to 05...

  4. 77 FR 15605 - Mobile Commerce and Personalization Promotion

    Science.gov (United States)

    2012-03-16

    ... POSTAL SERVICE 39 CFR Part 111 Mobile Commerce and Personalization Promotion AGENCY: Postal... reduction for the mobile commerce and personalization promotion, and the revised mailing standards to... * * * * * [Revise the title of 3.0 as follows:] 3.0 Mobile Commerce and Personalization Promotion 3.1 Program...

  5. 10 CFR 490.302 - Vehicle acquisition mandate schedule.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Vehicle acquisition mandate schedule. 490.302 Section 490... Alternative Fuel Provider Vehicle Acquisition Mandate § 490.302 Vehicle acquisition mandate schedule. (a) Except as provided in section 490.304 of this part, of the light duty motor vehicles newly acquired by a...

  6. MR-based attenuation correction for PET/MRI neurological studies with continuous-valued attenuation coefficients for bone through a conversion from R2* to CT-Hounsfield units.

    Science.gov (United States)

    Juttukonda, Meher R; Mersereau, Bryant G; Chen, Yasheng; Su, Yi; Rubin, Brian G; Benzinger, Tammie L S; Lalush, David S; An, Hongyu

    2015-05-15

    MR-based correction for photon attenuation in PET/MRI remains challenging, particularly for neurological applications requiring quantitation of data. Existing methods are either not sufficiently accurate or are limited by the computation time required. The goal of this study was to develop an MR-based attenuation correction method that accurately separates bone tissue from air and provides continuous-valued attenuation coefficients for bone. PET/MRI and CT datasets were obtained from 98 subjects (mean age [±SD]: 66yrs [±9.8], 57 females) using an IRB-approved protocol and with informed consent. Subjects were injected with 352±29MBq of (18)F-Florbetapir tracer, and PET acquisitions were begun either immediately or 50min after injection. CT images of the head were acquired separately using a PET/CT system. Dual echo ultrashort echo-time (UTE) images and two-point Dixon images were acquired. Regions of air were segmented via a threshold of the voxel-wise multiplicative inverse of the UTE echo 1 image. Regions of bone were segmented via a threshold of the R2* image computed from the UTE echo 1 and UTE echo 2 images. Regions of fat and soft tissue were segmented using fat and water images decomposed from the Dixon images. Air, fat, and soft tissue were assigned linear attenuation coefficients (LACs) of 0, 0.092, and 0.1cm(-1), respectively. LACs for bone were derived from a regression analysis between corresponding R2* and CT values. PET images were reconstructed using the gold standard CT method and the proposed CAR-RiDR method. The RiDR segmentation method produces mean Dice coefficient±SD across subjects of 0.75±0.05 for bone and 0.60±0.08 for air. The CAR model for bone LACs greatly improves accuracy in estimating CT values (28.2%±3.0 mean error) compared to the use of a constant CT value (46.9%±5.8, punits. From our analysis, we conclude that the proposed method closely approaches (<3% error) the gold standard CT-scaled method in PET reconstruction accuracy

  7. MR angiography of eddy-current-free MR imaging system with a 3T permanent magnet

    International Nuclear Information System (INIS)

    Nishimura, H.; Watanabe, S.; Takeuchi, H.

    1991-01-01

    This paper reports that, the authors main purpose was to evaluate two-dimensional time flight MR angiography in the visualization of vascular structure by using an eddy-current-free 0.3-T permanent magnet MR imaging system. The authors have developed multisection acquisition technique for two-dimensional time-of-flight MR angiography with the use of velocity-compensated gradient echoes. MR angiograms were obtained with a ray-tracing algorithm of the new modified maximum intensity projection at various viewing angles. These angiograms are displayed on cathode-ray tubes in a high-speed cyclic mode to depict the front-rear relation of vessels for better recognition. With an eddy-current-free permanent magnet system, two-dimensional time-of-flight angiography could clearly depict intracranial vascular structure, cervical vessels, and vessels of the extremities with thin-section (2 or 3 mm) acquisition. A high flip angle (90 degrees) with a short TR enabled better differentiation between blood flow and stationary tissues. Stenosis of the carotids could be detected in accordance with digital subtraction angiography

  8. 75 FR 72792 - Commerce Spectrum Management Advisory Committee Meeting

    Science.gov (United States)

    2010-11-26

    ... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration Commerce... Administration, U.S. Department of Commerce. ACTION: Notice of open meeting by teleconference. SUMMARY: This notice announces a public meeting of the Commerce Spectrum Management Advisory Committee (Committee...

  9. Perfusion MR imaging for differentiation of benign and malignant meningiomas

    International Nuclear Information System (INIS)

    Zhang, Hao; Roediger, Lars A.; Oudkerk, Matthijs; Shen, Tianzhen; Miao, Jingtao

    2008-01-01

    Our purpose was to determine whether perfusion MR imaging can be used to differentiate benign and malignant meningiomas on the basis of the differences in perfusion of tumor parenchyma and/or peritumoral edema. A total of 33 patients with preoperative meningiomas (25 benign and 8 malignant) underwent conventional and dynamic susceptibility contrast perfusion MR imaging. Maximal relative cerebral blood volume (rCBV) and the corresponding relative mean time to enhance (rMTE) (relative to the contralateral normal white matter) in both tumor parenchyma and peritumoral edema were measured. The independent samples t-test was used to determine whether there was a statistically significant difference in the mean rCBV and rMTE ratios between benign and malignant meningiomas. The mean maximal rCBV values of benign and malignant meningiomas were 7.16±4.08 (mean±SD) and 5.89±3.86, respectively, in the parenchyma, and 1.05±0.96 and 3.82±1.39, respectively, in the peritumoral edema. The mean rMTE values were 1.16±0.24 and 1.30±0.32, respectively, in the parenchyma, and 0.91±0.25 and 1.24±0.35, respectively, in the peritumoral edema. The differences in rCBV and rMTE values between benign and malignant meningiomas were not statistically significant (P>0.05) in the parenchyma, but both were statistically significant (P<0.05) in the peritumoral edema. Perfusion MR imaging can provide useful information on meningioma vascularity which is not available from conventional MRI. Measurement of maximal rCBV and corresponding rMTE values in the peritumoral edema is useful in the preoperative differentiation between benign and malignant meningiomas. (orig.)

  10. 75 FR 38779 - Commerce Spectrum Management Advisory Committee Meeting

    Science.gov (United States)

    2010-07-06

    ... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration Commerce... Administration, U.S. Department of Commerce. ACTION: Notice of open meeting. SUMMARY: This notice announces a public meeting of the Commerce Spectrum Management Advisory Committee (Committee). The Committee provides...

  11. 75 FR 7234 - Commerce Spectrum Management Advisory Committee Meeting

    Science.gov (United States)

    2010-02-18

    ... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration Commerce... Administration, U.S. Department of Commerce. ACTION: Notice of Open Meeting. SUMMARY: This notice announces a public meeting of the Commerce Spectrum Management Advisory Committee (Committee). The Committee provides...

  12. 75 FR 64699 - Commerce Spectrum Management Advisory Committee Meeting

    Science.gov (United States)

    2010-10-20

    ... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration Commerce... Administration, U.S. Department of Commerce. ACTION: Notice of open meeting. SUMMARY: This notice announces a public meeting of the Commerce Spectrum Management Advisory Committee (Committee). The Committee provides...

  13. 75 FR 21602 - Commerce Spectrum Management Advisory Committee Meeting

    Science.gov (United States)

    2010-04-26

    ... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration Commerce... Administration, U.S. Department of Commerce. ACTION: Notice of open meeting. SUMMARY: This notice announces a public meeting of the Commerce Spectrum Management Advisory Committee (Committee). The Committee provides...

  14. 75 FR 75968 - Commerce Spectrum Management Advisory Committee Meeting

    Science.gov (United States)

    2010-12-07

    ... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration Commerce... Administration, U.S. Department of Commerce. ACTION: Notice of open meeting. SUMMARY: This notice announces a public meeting of the Commerce Spectrum Management Advisory Committee (Committee). The Committee provides...

  15. 77 FR 25145 - Commerce Spectrum Management Advisory Committee Meeting

    Science.gov (United States)

    2012-04-27

    ... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration Commerce... Administration, U.S. Department of Commerce. ACTION: Notice of open meeting. SUMMARY: This notice announces a public meeting of the Commerce Spectrum Management Advisory Committee (Committee). The Committee provides...

  16. 78 FR 38340 - Federal Acquisition Regulation; Submission for OMB Review; Right of First Refusal of Employment

    Science.gov (United States)

    2013-06-26

    ... information provided. FOR FURTHER INFORMATION CONTACT: Mr. Michael O. Jackson, Procurement Analyst, Office of Governmentwide Acquisition Policy, GSA, at (202) 208-4949 or via email at michaelo.jackson@gsa.gov...

  17. Gadolinium-enhanced excretory MR urography: comparison with MR urography using HASTE technique

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lee, Jeong Min; Han, Young Min; Cheong, Gyung Ho; Oh, Hee Sul; Kim, Chong Soo; Park, Sung Kwang; Kim, Young Gon

    2000-01-01

    To compare the feasibility of gadolinium-enhanced excretory MR urography (GEMRU) and conventional MR urography using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in patients with hydronephrosis or non-visualized kidney. Fifteen patients with hydronephrosis or non-visualized kidney, as demonstrated by ultrasonography or intravenous urography, were enrolled in this study. Nine were men and six were women, and their age ranged from 18 to 77 (mean, 60.6) years. For all MR examinations, a 1.5T MR unit was employed. For breath-hold MR urography, the HASTE technique (MRU) was used, and reconstruction involved the use of a maximum intensity-projection (MIP) algorithm. For gadolinium-enhanced excretory MR urography, the fast low angle shot (FLASH) 3-D method was used and images were obtained at 5, 10, 20, and 30 minutes, and reconstruction again involved the use of MIP algorithm. In some cases, additional GEMRU was obtained 24 hour after contrast material injection, and an MIP algorithm was used for reconstruction. MRU and GEMRU were independently interpreted by two radiologists who for quantitative analysis compared SNR with CNR, and at each anatomic level qualitatively analyzed morphologic accuracy and diagnostic value of the lesions. In quantitative analysis, SNR and CNR differences between the two sequences at the renal pelvis and the level of the ureter were not significant (p greater than 0.05). In qualitative analysis, GEMRU was superior to MRU for the assessment of evaluated ureter at each level (p less than 0.05), anatomic anomaly and intrinsic tumor. Ureteral stones, however, were more easily diagnosed with MRU. For assessment of the ureter GEMRU is superior to MRU and has the advantage of evaluating renal function. We believe that for evaluation of the urinary tract, especially the distal ureter, GEMRU may be a valuable adjunct to routine MR urography. (author)

  18. Constraint on reconstructed f(R) gravity models from gravitational waves

    Science.gov (United States)

    Lee, Seokcheon

    2018-06-01

    The gravitational wave (GW) detection of a binary neutron star inspiral made by the Advanced LIGO and Advanced Virgo paves the unprecedented way for multi-messenger observations. The propagation speed of this GW can be scrutinized by comparing the arrival times between GW and neutrinos or photons. It provides the constraint on the mass of the graviton. f(R) gravity theories have the habitual non-zero mass gravitons in addition to usual massless ones. Previously, we show that the model independent f(R) gravity theories can be constructed from the both background evolution and the matter growth with one undetermined parameter. We show that this parameter can be constrained from the graviton mass bound obtained from GW detection. Thus, the GW detection provides the invaluable constraint on the validity of f(R) gravity theories.

  19. Cosmic constraint on massive neutrinos in viable f(R) gravity with producing ΛCDM background expansion

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Jianbo; Wu, Yabo; Wang, Yan; Yang, Weiqiang [Liaoning Normal University, Department of Physics, Dalian (China); Liu, Molin [Xinyang Normal University, Department of Physics, Xinyang (China)

    2016-12-15

    Tensions between several cosmic observations were found recently, such as the inconsistent values of H{sub 0} (or σ{sub 8}) were indicated by the different cosmic observations. Introducing the massive neutrinos in ΛCDM could potentially solve the tensions. Viable f(R) gravity producing ΛCDM background expansion with massive neutrinos is investigated in this paper. We fit the current observational data: Planck-2015 CMB, RSD, BAO, and SNIa to constrain the mass of neutrinos in viable f(R) theory. The constraint results at 95% confidence level are: Σm{sub ν} < 0.202 eV for the active-neutrino case, m{sub ν,sterile}{sup eff} < 0.757 eV with N{sub eff} < 3.22 for the sterile neutrino case. For the effects due to the mass of the neutrinos, the constraint results on model parameter at 95% confidence level become f{sub R0} x 10{sup -6} > -1.89 and f{sub R0} x 10{sup -6} > -2.02 for two cases, respectively. It is also shown that the fitting values of several parameters much depend on the neutrino properties, such as the cold dark matter density, the cosmological quantities at matter-radiation equality, the neutrino density and the fraction of baryonic mass in helium. Finally, the constraint result shows that the tension between direct and CMB measurements of H{sub 0} gets slightly weaker in the viable f(R) model than that in the base ΛCDM model. (orig.)

  20. 76 FR 27636 - Commerce Spectrum Management Advisory Committee Meeting

    Science.gov (United States)

    2011-05-12

    ... DEPARTMENT OF COMMERCE National Telecommunications and Information Administration Commerce... Administration, U.S. Department of Commerce. ACTION: Notice of open meeting, room location change. SUMMARY: This notice announces a change in the room location of a public meeting of the Commerce Spectrum Management...

  1. 12 CFR 225.132 - Acquisition of assets.

    Science.gov (United States)

    2010-01-01

    ... it constitutes the acquisition, in whole or in part, of a going concern. 2 1 Section 225.4(c)(3) of... Regulation Y, the acquisition of a going concern requires prior Board approval. (c) The following examples... going concern. [39 FR 35128, Sept. 30, 1974, as amended at Reg. Y, 57 FR 28779, June 29, 1992] ...

  2. 7 CFR 1220.103 - Commerce.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Commerce. 1220.103 Section 1220.103 Agriculture... CONSUMER INFORMATION Soybean Promotion and Research Order Definitions § 1220.103 Commerce. The term commerce means interstate, foreign, or intrastate commerce. ...

  3. Probing the f(R) formalism through gravitational wave polarizations

    International Nuclear Information System (INIS)

    Alves, M.E.S.; Miranda, O.D.; Araujo, J.C.N. de

    2009-01-01

    The direct observation of gravitational waves (GW) in the near future, and the corresponding determination of the number of independent polarizations, is a powerful tool to test general relativity and alternative theories of gravity. In the present work we use the Newman-Penrose formalism to characterize GWs in quadratic gravity and in a particular class of f(R) Lagrangians. We find that both quadratic gravity and the f(R) theory belong to the most general invariant class of GWs, i.e., they can present up to six independent polarizations of GWs. For a particular combination of the parameters, we find that quadratic gravity can present up to five polarizations states. On the other hand, if we use the Palatini approach for f(R) theories, GWs present only the usual two transverse-traceless polarizations such as in general relativity. Thus, we conclude that the observation of GWs can strongly constrain the suitable formalism for these theories.

  4. Max CAPR: high-resolution 3D contrast-enhanced MR angiography with acquisition times under 5 seconds.

    Science.gov (United States)

    Haider, Clifton R; Borisch, Eric A; Glockner, James F; Mostardi, Petrice M; Rossman, Phillip J; Young, Phillip M; Riederer, Stephen J

    2010-10-01

    High temporal and spatial resolution is desired in imaging of vascular abnormalities having short arterial-to-venous transit times. Methods that exploit temporal correlation to reduce the observed frame time demonstrate temporal blurring, obfuscating bolus dynamics. Previously, a Cartesian acquisition with projection reconstruction-like (CAPR) sampling method has been demonstrated for three-dimensional contrast-enhanced angiographic imaging of the lower legs using two-dimensional sensitivity-encoding acceleration and partial Fourier acceleration, providing 1mm isotropic resolution of the calves, with 4.9-sec frame time and 17.6-sec temporal footprint. In this work, the CAPR acquisition is further undersampled to provide a net acceleration approaching 40 by eliminating all view sharing. The tradeoff of frame time and temporal footprint in view sharing is presented and characterized in phantom experiments. It is shown that the resultant 4.9-sec acquisition time, three-dimensional images sets have sufficient spatial and temporal resolution to clearly portray arterial and venous phases of contrast passage. It is further hypothesized that these short temporal footprint sequences provide diagnostic quality images. This is tested and shown in a series of nine contrast-enhanced MR angiography patient studies performed with the new method.

  5. 77 FR 57949 - Federal Acquisition Regulation; Positive Law Codification of Title 41

    Science.gov (United States)

    2012-09-18

    ... establishment and use of electronic commerce in Federal acquisition as required by 41 U.S.C. 2301. 4.502... previously approved under the Office of Management and Budget Control Number 1215-0017, titled: Records to be... executive means the individual appointed pursuant to 41 U.S.C. 1702(c) who is responsible for management...

  6. On Analytical Solutions of f(R) Modified Gravity Theories in FLRW Cosmologies

    Science.gov (United States)

    Domazet, Silvije; Radovanović, Voja; Simonović, Marko; Štefančić, Hrvoje

    2013-02-01

    A novel analytical method for f(R) modified theories without matter in Friedmann-Lemaitre-Robertson-Walker (FLRW) spacetimes is introduced. The equation of motion for the scale factor in terms of cosmic time is reduced to the equation for the evolution of the Ricci scalar R with the Hubble parameter H. The solution of equation of motion for actions of the form of power law in Ricci scalar R is presented with a detailed elaboration of the action quadratic in R. The reverse use of the introduced method is exemplified in finding functional forms f(R), which leads to specified scale factor functions. The analytical solutions are corroborated by numerical calculations with excellent agreement. Possible further applications to the phases of inflationary expansion and late-time acceleration as well as f(R) theories with radiation are outlined.

  7. Data acquisition and processing system for surface ionization mass spectrometers (types MS5 and R20)

    International Nuclear Information System (INIS)

    Dubois, J.-C.; Retali, G.; Grandcollot, P.; Hagemann, R.

    1977-01-01

    The data acquisition and processing system developed for surface ionization mass spectrometers is described. The main interest of the system is to shorten significantly the duration of isotopic analysis, the results of which are printed almost immediately after the end of the acquisition of the data. The quality of the results is also improved, particularly for isotopes at low concentration owing to an automatic range selection unit driven by the computer. The processing program, which includes several options, is adapted to all types of isotopic analysis. This system, in use for more than two years, has demonstrated its versatility and its safety [fr

  8. f(R in Holographic and Agegraphic Dark Energy Models and the Generalized Uncertainty Principle

    Directory of Open Access Journals (Sweden)

    Barun Majumder

    2013-01-01

    Full Text Available We studied a unified approach with the holographic, new agegraphic, and f(R dark energy model to construct the form of f(R which in general is responsible for the curvature driven explanation of the very early inflation along with presently observed late time acceleration. We considered the generalized uncertainty principle in our approach which incorporated the corrections in the entropy-area relation and thereby modified the energy densities for the cosmological dark energy models considered. We found that holographic and new agegraphic f(R gravity models can behave like phantom or quintessence models in the spatially flat FRW universe. We also found a distinct term in the form of f(R which goes as R 3 / 2 due to the consideration of the GUP modified energy densities. Although the presence of this term in the action can be important in explaining the early inflationary scenario, Capozziello et al. recently showed that f(R ~ R 3 / 2 leads to an accelerated expansion, that is, a negative value for the deceleration parameter q which fits well with SNeIa and WMAP data.

  9. Temperature profile and chemical data from CTD casts in the North Atlantic Ocean and Gulf of Mexico from NOAA Ship RESEARCHER from 1976-10-08 to 1977-10-30 (NODC Accession 8000168)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Temperature profile and chemical data were collected using CTD casts from NOAA Ship RESEARCHER in the North Atlantic Ocean and Gulf of Mexico from 08 October 1976 to...

  10. Reconstructing an f(R) model from holographic dark energy: using the observational evidence

    International Nuclear Information System (INIS)

    Saaidi, Kh; Aghamohammadi, A

    2012-01-01

    We investigate the correspondence relation between f(R) gravity and an interacting holographic dark energy (HDE). By obtaining the conditions needed for some observational evidence such as positive acceleration expansion of the Universe, crossing the phantom divide line and validity of the thermodynamics second law in an interacting HDE model and corresponding it with the f(R) model of gravity, we find a viable f(R) model that can explain the present Universe. We also obtain the explicit evolutionary forms of the corresponding scalar field, potential and scale factor of the Universe. (paper)

  11. String duality transformations in f(R) gravity from Noether symmetry approach

    Energy Technology Data Exchange (ETDEWEB)

    Capozziello, Salvatore [Dipartimento di Fisica, Università di Napoli ' ' Federico II' ' , Compl. Univ. di Monte S. Angelo, Edificio G, Via Cinthia, I-80126, Napoli (Italy); Gionti, Gabriele S.J. [Specola Vaticana, Vatican City, V-00120, Vatican City State (Vatican City State, Holy See); Vernieri, Daniele, E-mail: capozziello@na.inf.it, E-mail: ggionti@as.arizona.edu, E-mail: vernieri@iap.fr [Sorbonne Universités, UPMC Univ Paris 6 et CNRS, UMR 7095, Institut d' Astrophysique de Paris, GReCO, 98bis Bd Arago, 75014 Paris (France)

    2016-01-01

    We select f(R) gravity models that undergo scale factor duality transformations. As a starting point, we consider the tree-level effective gravitational action of bosonic String Theory coupled with the dilaton field. This theory inherits the Busher's duality of its parent String Theory. Using conformal transformations of the metric tensor, it is possible to map the tree-level dilaton-graviton string effective action into f(R) gravity, relating the dilaton field to the Ricci scalar curvature. Furthermore, the duality can be framed under the standard of Noether symmetries and exact cosmological solutions are derived. Using suitable changes of variables, the string-based f(R) Lagrangians are shown in cases where the duality transformation becomes a parity inversion.

  12. String duality transformations in f(R) gravity from Noether symmetry approach

    International Nuclear Information System (INIS)

    Capozziello, Salvatore; Gionti, Gabriele S.J.; Vernieri, Daniele

    2016-01-01

    We select f(R) gravity models that undergo scale factor duality transformations. As a starting point, we consider the tree-level effective gravitational action of bosonic String Theory coupled with the dilaton field. This theory inherits the Busher's duality of its parent String Theory. Using conformal transformations of the metric tensor, it is possible to map the tree-level dilaton-graviton string effective action into f(R) gravity, relating the dilaton field to the Ricci scalar curvature. Furthermore, the duality can be framed under the standard of Noether symmetries and exact cosmological solutions are derived. Using suitable changes of variables, the string-based f(R) Lagrangians are shown in cases where the duality transformation becomes a parity inversion

  13. Unifying inflation with dark energy in modified F(R) Horava-Lifshitz gravity

    International Nuclear Information System (INIS)

    Elizalde, E.; Saez-Gomez, D.; Nojiri, S.; Odintsov, S.D.

    2010-01-01

    We study FRW cosmology for a non-linear modified F(R) Horava-Lifshitz gravity which has a viable convenient counterpart. A unified description of early-time inflation and late-time acceleration is possible in this theory, but the cosmological dynamic details are generically different from the ones of the convenient viable F(R) model. Remarkably, for some specific choice of parameters they do coincide. The emergence of finite-time future singularities is investigated in detail. It is shown that these singularities can be cured by adding an extra, higher-derivative term, which turns out to be qualitatively different when compared with the corresponding one of the convenient F(R) theory. (orig.)

  14. MR-based source localization for MR-guided HDR brachytherapy

    Science.gov (United States)

    Beld, E.; Moerland, M. A.; Zijlstra, F.; Viergever, M. A.; Lagendijk, J. J. W.; Seevinck, P. R.

    2018-04-01

    For the purpose of MR-guided high-dose-rate (HDR) brachytherapy, a method for real-time localization of an HDR brachytherapy source was developed, which requires high spatial and temporal resolutions. MR-based localization of an HDR source serves two main aims. First, it enables real-time treatment verification by determination of the HDR source positions during treatment. Second, when using a dummy source, MR-based source localization provides an automatic detection of the source dwell positions after catheter insertion, allowing elimination of the catheter reconstruction procedure. Localization of the HDR source was conducted by simulation of the MR artifacts, followed by a phase correlation localization algorithm applied to the MR images and the simulated images, to determine the position of the HDR source in the MR images. To increase the temporal resolution of the MR acquisition, the spatial resolution was decreased, and a subpixel localization operation was introduced. Furthermore, parallel imaging (sensitivity encoding) was applied to further decrease the MR scan time. The localization method was validated by a comparison with CT, and the accuracy and precision were investigated. The results demonstrated that the described method could be used to determine the HDR source position with a high accuracy (0.4–0.6 mm) and a high precision (⩽0.1 mm), at high temporal resolutions (0.15–1.2 s per slice). This would enable real-time treatment verification as well as an automatic detection of the source dwell positions.

  15. WE-E-BRE-08: Impact of IUdR in Rat 9L Glioma Cell Survival for 25–35 KeV Photo-Activated Auger Electron Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, D; Hogstrom, K [Louisiana State University, Baton Rouge, LA (United States); Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States); Brown, T; Dugas, J; Varnes, M [Mary Bird Perkins Cancer Center, Baton Rouge, LA (United States); Matthews, K [Louisiana State University, Baton Rouge, LA (United States)

    2014-06-15

    Purpose: To determine the biological effect from Auger electrons with 9% and 18% iododeoxyuridine (IUdR) incorporated into the DNA of rat 9L glioma cells at photon energies above and below the K-edge of iodine (33.2 keV). Methods: Rat 9L glioma cell survival versus dose curves with 0%, 9%, and 18% thymidine replacement with IUdR were measured using four irradiation energies (4 MV x-rays; monochromatic 35, 30, and 25 keV synchrotron photons). For each of 11 conditions (Energy, %IUdR) survival curves were fit to the data (826 cell cultures) using the linear-quadratic model. The ratio of doses resulting in 10% survival gave sensitization enhancement ratios (SER10) from which contributions due to linear-energy transfer (LET), radiosensitization (RS), and Auger effect (AE) were extracted. Results: At 35, 30, and 25 keV, SER10,LET values were 1.08±0.03, 1.22±0.02, and 1.37±0.02, respectively. At 4 MV SER10,RS values for 9% and 18% IUdR were 1.28±0.02 and 1.40±0.02, respectively. Assuming LET effects are independent of %IUdR and radiosensitization effects are independent of energy, SER10,AE values for 18% IUdR at 35, 30, and 25 keV were 1.35±0.05, 1.06±0.03, and 0.98±0.03, respectively; values for 9% IUdR at 35 and 25 keV were 1.01±0.04 and 0.82±0.02, respectively. Conclusion: For 18% IUdR the radiosensitization effect of 1.40 and the Auger effect of 1.35 at 35 keV are equally important to the combined effect of 1.90. No measureable Auger effect was observed for energies below the K-edge at 20 and 25 keV, as expected. The insignificant Auger effect at 9% IUdR was not expected. Additional data (40–70 keV) and radiobiological modeling are being acquired to better understand the energy dependence of Auger electron therapy with IUdR. Funding support in part by the National Science Foundation Graduate Research Fellowship Program and in part by Contract No. W81XWH-10-1-0005 awarded by the U.S. Army Research Acquisition Activity. This paper does not necessarily

  16. Late time acceleration of the universe in f(R) gravity model

    International Nuclear Information System (INIS)

    Mukherjee, Ankan

    2014-01-01

    In this work, a new way to look at the nature of late time dynamics of the universe for f(R) gravity models using the contracted Bianchi Identity has been proposed. As the Einstein field equations contain derivatives of the curvature scalar R, the contracted Bianchi identity yields a second order nonlinear differential equation in H, the Hubble parameter. This equation is studied for two particular forms of f(R), and the late time behaviour of the model is discussed. (author)

  17. Electrocardiographically gated snapshot MR angiography

    International Nuclear Information System (INIS)

    Brown, D.G.; Holsinger, A.E.; Riederer, S.J.

    1990-01-01

    The purpose of this paper is to evaluate the effectiveness of applying ultrashort (∼12 msec) TR times and measuring the central phase encodings first in improving the accuracy of vascular depiction in MR angiography. The imaging method combines ultrashort TR imaging techniques with time-of-flight MR angiography. The central phase-encoding views are acquired first, and an inversion-recovery contrast preparation pulse is applied prior to image acquisition to null signal from static tissues. In initial studies, the method was tested on phantoms and volunteers. The contrast-preparation phase effectively nulls static spins at the start of image acquisition. During the TL period fresh blood flows into the imaging section; even slowly moving blood is fully replaced

  18. Parallel reconstruction in accelerated multivoxel MR spectroscopy

    NARCIS (Netherlands)

    Boer, V. O.; Klomp, D. W. J.; Laterra, J.; Barker, P. B.

    PurposeTo develop the simultaneous acquisition of multiple voxels in localized MR spectroscopy (MRS) using sensitivity encoding, allowing reduced total scan time compared to conventional sequential single voxel (SV) acquisition methods. MethodsDual volume localization was used to simultaneously

  19. Stability of the Einstein static universe in f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Shabani, Hamid [University of Sistan and Baluchestan, Physics Department, Faculty of Sciences, Zahedan (Iran, Islamic Republic of); Ziaie, Amir Hadi [Kahnooj Branch, Islamic Azad University, Department of Physics, Kerman (Iran, Islamic Republic of)

    2017-01-15

    The Einstein static (ES) universe has played a major role in various emergent scenarios recently proposed in order to cure the problem of the initial singularity of the standard model of cosmology. In the model we address, we study the existence and stability of an ES universe in the context of f(R, T) modified theories of gravity. Considering specific forms of the f(R, T) function, we seek for the existence of solutions representing ES state. Using dynamical system techniques along with numerical analysis, we find two classes of solutions: the first one is always unstable of the saddle type, while the second is always stable so that its dynamical behavior corresponds to a center equilibrium point. The importance of the second class of solutions is due to the significant role they play in constructing non-singular emergent models in which the universe could have experienced past-eternally a series of infinite oscillations about such an initial static state after which it enters, through a suitable physical mechanism, to an inflationary era. Considering specific forms for the functionality of f(R, T), we show that this theory is capable of providing cosmological solutions which admit emergent universe (EU) scenarios. We also investigate homogeneous scalar perturbations for the mentioned models. The stability regions of the solutions are parametrized by a linear equation of state (EoS) parameter and other free parameters that will be introduced for the models. Our results suggest that modifications in f(R, T) gravity would lead to stable solutions which are unstable in f(R) gravity model. (orig.)

  20. Stability of the Einstein static universe in f(R, T) gravity

    International Nuclear Information System (INIS)

    Shabani, Hamid; Ziaie, Amir Hadi

    2017-01-01

    The Einstein static (ES) universe has played a major role in various emergent scenarios recently proposed in order to cure the problem of the initial singularity of the standard model of cosmology. In the model we address, we study the existence and stability of an ES universe in the context of f(R, T) modified theories of gravity. Considering specific forms of the f(R, T) function, we seek for the existence of solutions representing ES state. Using dynamical system techniques along with numerical analysis, we find two classes of solutions: the first one is always unstable of the saddle type, while the second is always stable so that its dynamical behavior corresponds to a center equilibrium point. The importance of the second class of solutions is due to the significant role they play in constructing non-singular emergent models in which the universe could have experienced past-eternally a series of infinite oscillations about such an initial static state after which it enters, through a suitable physical mechanism, to an inflationary era. Considering specific forms for the functionality of f(R, T), we show that this theory is capable of providing cosmological solutions which admit emergent universe (EU) scenarios. We also investigate homogeneous scalar perturbations for the mentioned models. The stability regions of the solutions are parametrized by a linear equation of state (EoS) parameter and other free parameters that will be introduced for the models. Our results suggest that modifications in f(R, T) gravity would lead to stable solutions which are unstable in f(R) gravity model. (orig.)

  1. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Izquierdo-Garcia, David [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Sawiak, Stephen J. [University of Cambridge, Wolfson Brain Imaging Centre, Cambridge (United Kingdom); Knesaurek, Karin; Machac, Joseph [Mount Sinai School of Medicine, Division of Nuclear Medicine, Department of Radiology, New York, NY (United States); Narula, Jagat [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Fuster, Valentin [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); The Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid (Spain); Fayad, Zahi A. [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States)

    2014-08-15

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R{sup 2} = 0.98, p < 0.001; beta group 10.31 ± 69.86 %, R{sup 2} = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  2. WIND DIRECTION, pH and other data from FOX in the Caribbean Sea from 1974-08-30 to 1974-08-31 (NCEI Accession 7601844)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data were collected in the Caribbean Sea from August 30-31, 1974. HMS FOX of the British navy was used to collect the data. Mr. Paul Ruiz, Tauton, Somerset, UK...

  3. 76 FR 13297 - Defense Federal Acquisition Regulation Supplement; Technical Amendments

    Science.gov (United States)

    2011-03-11

    ... 215 Government procurement. Ynette R. Shelkin, Editor, Defense Acquisition Regulations System... Director, Defense Procurement and Acquisition Policy. DATES: Effective Date: March 11, 2011. Applicability... adding a section at 215.300 with a reference to Director, Defense Procurement and Acquisition Policy...

  4. 4-D PET-MR with Volumetric Navigators and Compressed Sensing

    DEFF Research Database (Denmark)

    Pedemonte, Stefano; Catana, Ciprian; Van Leemput, Koen

    2015-01-01

    Hybrid PET-MR scanners acquire multi-modal signals simultaneously, eliminating the requirement of software alignment between the MR and PET imaging data. However, the acquisition of high-resolution MR and PET images requires long scanning times, therefore movement of the subject during the acquis...

  5. Algorithm comparison for schedule optimization in MR fingerprinting.

    Science.gov (United States)

    Cohen, Ouri; Rosen, Matthew S

    2017-09-01

    In MR Fingerprinting, the flip angles and repetition times are chosen according to a pseudorandom schedule. In previous work, we have shown that maximizing the discrimination between different tissue types by optimizing the acquisition schedule allows reductions in the number of measurements required. The ideal optimization algorithm for this application remains unknown, however. In this work we examine several different optimization algorithms to determine the one best suited for optimizing MR Fingerprinting acquisition schedules. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. 75 FR 57690 - Acquisition Regulation: Sustainable Acquisition

    Science.gov (United States)

    2010-09-22

    ... general guidelines issued by OMB. OMB's guidelines were published at 67 FR 8452 (February 22, 2002), and DOE's guidelines were published at 67 FR 62446 (October 7, 2002). DOE has reviewed today's rule under... products. (5) Environmentally preferable and energy efficient electronics including desktop computers...

  7. 77 FR 64796 - Membership of the Bureau of Industry and Security Performance Review Board

    Science.gov (United States)

    2012-10-23

    ...: Ruthie B. Stewart, Department of Commerce Human Resources Operations Center (DOCHROC), Office of Staffing, Recruitment, and Classification/Executive Resources Operations, 14th and Constitution Avenue NW., Room 7419... Classification, Department of Commerce Human Resources Operations Center. [FR Doc. 2012-26062 Filed 10-22-12; 8...

  8. Electronic Commerce - Hürden, Entwicklungspotential, Konsequenzen : Ergebnisse aus der Electronic Commerce Enquete

    OpenAIRE

    Müller, Günter; Schoder, Detlef

    1999-01-01

    Vorhersagen zu Wachstum und Volumen elektronisch gestützten Geschäftsverkehrs zeichnen überwiegend ein sehr positives Zukunftsbild. In krassem Gegensatz dazu stehen Aussagen aus ex post-Analysen des Electronic Commerce zu „harten“ ökonomischen Variablen wie etwa Umsatz- oder Gewinnsteigerung, Kostensenkung und Erhöhung von Marktanteilen. In vielen Fällen bewahrheiten sich euphorische Voraussagen zum Erfolg von Electronic Commerce-Aktivitäten für Unternehmen nicht einmal annähernd. Verlustmeld...

  9. Exact solutions for scalar field cosmology in f(R) gravity

    Science.gov (United States)

    Maharaj, S. D.; Goswami, R.; Chervon, S. V.; Nikolaev, A. V.

    2017-09-01

    We study scalar field FLRW cosmology in the content of f(R) gravity. Our consideration is restricted to the spatially flat Friedmann universe. We derived the general evolution equations of the model, and showed that the scalar field equation is automatically satisfied for any form of the f(R) function. We also derived representations for kinetic and potential energies, as well as for the acceleration in terms of the Hubble parameter and the form of the f(R) function. Next we found the exact cosmological solutions in modified gravity without specifying the f(R) function. With negligible acceleration of the scalar curvature, we found that the de Sitter inflationary solution is always attained. Also we obtained new solutions with special restrictions on the integration constants. These solutions contain oscillating, accelerating, decelerating and even contracting universes. For further investigation, we selected special cases which can be applied with early or late inflation. We also found exact solutions for the general case for the model with negligible acceleration of the scalar curvature in terms of special Airy functions. Using initial conditions which represent the universe at the present epoch, we determined the constants of integration. This allows for the comparison of the scale factor in the new solutions with that for current stage of the universe evolution in the ΛCDM model.

  10. Data acquisition system using a C 90-10 computer

    International Nuclear Information System (INIS)

    Smiljanic, Gabro

    1969-05-01

    The aim of this study is to make possible the acquisition of experimental data by the memory of a numerical calculator. These data come from analog-to-digital converters that analyze the amplitude of the pulses provided by detectors. Normally the computer executes its main program (data processing, transfer on magnetic tape, visualization, etc.). When information is available at the output of a converter, an interruption of the main program is requested, and after agreement a subroutine supports access to the information in the computer. The author has also considered the bi- and tri-parametric acquisition. The calculator and the converters are commercial devices (calculator C 90-10 from CII and converter CA 12 or CA 25 from Intertechnique), while the systems of adaptation of the input-output levels and the visualization were studied and realized at the CEA Saclay. An interface device was built to connect the converters; it's the cable part of the system. On the other hand, the programs necessary for the operation of the calculator have been studied and developed; it is the program aspect of the system. As far as possible the interface is designed to be universal, i.e. it must be able to work with other brands of equipment. The acquisition of the data is carried out in two phases: a) the converter expresses the amplitude of the input signal in the form of a binary number which is transferred into the interface at the same time as an interruption of the main program is asked. b) After acceptance of this interruption, the subprogram supports the transfer of the information of the interface in the computer, then adds a unit to the word located at the address determined from the information received. In other words, the system behaves like an amplitude analyzer whose operation is well known. But it is of a much more flexible use because of the possibilities of quick adaptation of the programs to the needs of the considered experiment, of the possibility to treat

  11. Optimal visualization of focal nodular hyperplasia: quantitative and qualitative evaluation of single and multiphasic arterial phase acquisition at 1.5 T MR imaging.

    Science.gov (United States)

    Rousseau, Caroline; Ronot, Maxime; Vilgrain, Valérie; Zins, Marc

    2016-05-01

    To evaluate the qualitative and quantitative benefit of multiple arterial phase acquisitions for the depiction of hypervascularity in FNH explored MR imaging using an extracellular contrast agent. Between 2007 and 2014, all patients who underwent MR imaging for the exploration of FNH were included. The protocol included a single or a triple arterial phase ("single" and "triple" group, respectively). Arterial phases were visually divided into four types: (1) angiographic, (2) early, (3) late, and (4) portal. Signal intensity on arterial phase images was visually recorded as intense, moderate, or low for each lesion. Lesion-to-liver contrast (LLC) and relative lesion enhancement (RE) were calculated and compared between the two groups using the Mann-Whitney test. Thirty-five women were included (mean 45-year old, range 20-66), with 50 FNH (mean size 30 mm). Single and triple groups included 20 patients (30 FNH) and 15 patients (20 FNH), respectively. Signal intensity was intense in all lesions in the triple group and in 22/30 (73%) in the single group (p = 0.041). Intense signals were more frequently found in the early arterial phase (p < 0.001). RE was not significantly different (1.78 ± 0.84 vs. 1.98 ± 1.81 p = 0.430, in the single and triple groups, respectively) but LLC was significantly higher in the triple group (0.32 ± 0.10 vs. 0.22 ± 0.10, p = 0.005). LLC was significantly higher in the first two arterial phases in the triple group (p < 0.001). Acquisition of three arterial phases improves the visualization of hypervascularity of FNH, as lesions show high visual signal intensity and contrast. Optimal visualization is obtained in the early arterial phase.

  12. The experimental study of oxygen contrast MR ventilation imaging

    International Nuclear Information System (INIS)

    Yang Jian; Guo Youmin; Wu Xiaoming; Xi Nong; Wang Jianguo; Zhu Li; Lei Xiaoyan; Xie Enyi

    2003-01-01

    Objective: To study the feasibility and basic technology of the oxygen contrast MR ventilation imaging in lung. Methods: Six canine lungs were scanned by using inversion recovery pulse sequence with turbo spin echo acquisition before and after inhalation of the 100% oxygen as T 1 contrast agent, and the T 1 values were measured. The contrast-to-noise ratio (CNR) for each inversion recovery time was compared and the relationship between arterial blood oxygen pressure (PaO 2 ) and T 1 relaxation rate was observed. Subtraction technique was employed in the postprocessing of pre- and post-oxygen conditions. Results: Molecular oxygen could shorten the pulmonary T 1 value (average 13.37%, t=2.683, P 1 value of pre- and post-oxygen conditions. The relaxtivity of T 1 resulted in excellent linear correlation (r 2 =0.9974) with PaO 2 . Through the subtraction of pre- and post-oxygen image, the oxygen contrast MR ventilation -image was obtained. Conclusion: The oxygen contrast MR ventilation imaging has the feasibility and clinical potential for the assessment of regional pulmonary function

  13. Pseudodynamic MR imaging of temporomandibular joint disorders

    International Nuclear Information System (INIS)

    Nakasato, Tatsuhiko; Ehara, Shigeru

    1992-01-01

    Magnetic resonance (MR) imaging of the temporomandibular joint (TMJ) has now been established as a procedure of choice in the evaluation of TMJ disorders. In this study, we evaluated the dynamics of TMJ motion on MR imaging, which resembles arthrography. Sixty-eight TMJs in 38 symptomatic patients and one healthy volunteer were examined using pseudodynamic images with gradient echo sequences using a 0.5 Tesla MR unit and 8 cm circular planar surface coil. For depiction of each compartment of the meniscus, the optimum sequence was 200/15/2 (TR/TE/excitations) with 50 deg or 60 deg flip angle in gradient refocused acquisition in steady-state (GRASS) sequences. Three contiguous slices on sagittal MR images were routinely obtained at 14-18 different phases of the opening cycle and displayed in closed-loop cine fashion. Internal derangement was observed in 57% of 68 joints. The most common type was anterior meniscal displacement without reduction. Sideway and rotational displacements, observed in 10% each, were noted on both sagittal multislice images and axial reference images. As a pseudodynamic MR technique, jaw movement specifically designed to check bite procedure to adjust splints is useful for detecting the exact time of meniscal redisplacement on the second click. After conservative therapy for arthrosis, pseudodynamic MR provided information on changes in the meniscus and condylar relationship. Pseudodynamic MR with multiple phases is suitable for evaluating subtle motion abnormality of the meniscus and for post-therapeutic monitoring. (author)

  14. Pseudodynamic MR imaging of temporomandibular joint disorders

    Energy Technology Data Exchange (ETDEWEB)

    Nakasato, Tatsuhiko; Ehara, Shigeru (Iwate Medical Coll., Morioka (Japan). School of Medicine)

    1992-09-01

    Magnetic resonance (MR) imaging of the temporomandibular joint (TMJ) has now been established as a procedure of choice in the evaluation of TMJ disorders. In this study, we evaluated the dynamics of TMJ motion on MR imaging, which resembles arthrography. Sixty-eight TMJs in 38 symptomatic patients and one healthy volunteer were examined using pseudodynamic images with gradient echo sequences using a 0.5 Tesla MR unit and 8 cm circular planar surface coil. For depiction of each compartment of the meniscus, the optimum sequence was 200/15/2 (TR/TE/excitations) with 50 deg or 60 deg flip angle in gradient refocused acquisition in steady-state (GRASS) sequences. Three contiguous slices on sagittal MR images were routinely obtained at 14-18 different phases of the opening cycle and displayed in closed-loop cine fashion. Internal derangement was observed in 57% of 68 joints. The most common type was anterior meniscal displacement without reduction. Sideway and rotational displacements, observed in 10% each, were noted on both sagittal multislice images and axial reference images. As a pseudodynamic MR technique, jaw movement specifically designed to check bite procedure to adjust splints is useful for detecting the exact time of meniscal redisplacement on the second click. After conservative therapy for arthrosis, pseudodynamic MR provided information on changes in the meniscus and condylar relationship. Pseudodynamic MR with multiple phases is suitable for evaluating subtle motion abnormality of the meniscus and for post-therapeutic monitoring. (author).

  15. Chameleon halo modeling in f(R) gravity

    International Nuclear Information System (INIS)

    Li Yin; Hu, Wayne

    2011-01-01

    We model the chameleon effect on cosmological statistics for the modified gravity f(R) model of cosmic acceleration. The chameleon effect, required to make the model compatible with local tests of gravity, reduces force enhancement as a function of the depth of the gravitational potential wells of collapsed structure and so is readily incorporated into a halo model by including parameters for the chameleon mass threshold and rapidity of transition. We show that the abundance of halos around the chameleon mass threshold is enhanced by both the merging from below and the lack of merging to larger masses. This property also controls the power spectrum in the nonlinear regime and we provide a description of the transition to the linear regime that is valid for a wide range of f(R) models.

  16. Commerce Raiding: Historical Case Studies, 1755-2009

    Science.gov (United States)

    2013-10-01

    Histoire de la Marine française des origines à nos jours (Rennes, Fr.: Editions Ouest-France, 1994); for a bibliographical essay, Hervé Couteau...Ribadieu, Histoire maritime de Bordeaux. Aventures des corsaires marzagalli 53 meyers$:___WIP from C 032812:_Newport Papers:_NP_40 Commerce:_InDesign:03...see Henri Legohérel, Histoire de la Marine française (Paris: PUF, 1999), pp. 67–70; and Martine Acerra and Jean Meyer, Marines et Révolution

  17. Dissolved inorganic carbon, pH, alkalinity, temperature, salinity and other variables collected from discrete sample and profile observations using CTD, Coulometer for DIC measurement and other instruments from the MIRAI in the North Pacific Ocean from 2004-10-13 to 2004-11-08 (NODC Accession 0112262)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NODC Accession 0112262 includes chemical, discrete sample, physical and profile data collected from MIRAI in the North Pacific Ocean from 2004-10-13 to 2004-11-08...

  18. Electronic Commerce user manual

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-10

    This User Manual supports the Electronic Commerce Standard System. The Electronic Commerce Standard System is being developed for the Department of Defense of the Technology Information Systems Program at the Lawrence Livermore National Laboratory, operated by the University of California for the Department of Energy. The Electronic Commerce Standard System, or EC as it is known, provides the capability for organizations to conduct business electronically instead of through paper transactions. Electronic Commerce and Computer Aided Acquisition and Logistics Support, are two major projects under the DoD`s Corporate Information Management program, whose objective is to make DoD business transactions faster and less costly by using computer networks instead of paper forms and postage. EC runs on computers that use the UNIX operating system and provides a standard set of applications and tools that are bound together by a common command and menu system. These applications and tools may vary according to the requirements of the customer or location and may be customized to meet the specific needs of an organization. Local applications can be integrated into the menu system under the Special Databases & Applications option on the EC main menu. These local applications will be documented in the appendices of this manual. This integration capability provides users with a common environment of standard and customized applications.

  19. Electronic Commerce user manual

    Energy Technology Data Exchange (ETDEWEB)

    1992-04-10

    This User Manual supports the Electronic Commerce Standard System. The Electronic Commerce Standard System is being developed for the Department of Defense of the Technology Information Systems Program at the Lawrence Livermore National Laboratory, operated by the University of California for the Department of Energy. The Electronic Commerce Standard System, or EC as it is known, provides the capability for organizations to conduct business electronically instead of through paper transactions. Electronic Commerce and Computer Aided Acquisition and Logistics Support, are two major projects under the DoD's Corporate Information Management program, whose objective is to make DoD business transactions faster and less costly by using computer networks instead of paper forms and postage. EC runs on computers that use the UNIX operating system and provides a standard set of applications and tools that are bound together by a common command and menu system. These applications and tools may vary according to the requirements of the customer or location and may be customized to meet the specific needs of an organization. Local applications can be integrated into the menu system under the Special Databases Applications option on the EC main menu. These local applications will be documented in the appendices of this manual. This integration capability provides users with a common environment of standard and customized applications.

  20. MR cisternography after intrathecal Gd-DTPA application

    International Nuclear Information System (INIS)

    Reiche, Werner; Komenda, Yvonne; Steudel, Wolf-Ingo; Schick, Bernhard; Grunwald, Iris; Reith, Wolfgang

    2002-01-01

    The purpose of this study was to establish and to evaluate MR cisternography after intrathecal Gd-DTPA administration to detect rhinobasal cerebrospinal fluid (CSF) fistulae in patients with suspected CSF rhinorrhoea. Ten patients with suspected CSF rhinorrhoea were examined. The MR cisternography included the following investigation steps: acquisition of nonenhanced fat-suppressed T1-weighted spin-echo (SE) scans of the skull base and the paranasal sinuses, lumbar puncture with administration of 1 ml Gd-DTPA solute with 4 ml NaCl and performance of MR cisternography with the same fat-suppressed T1-weighted sequences as used initially. In 10 patients with suspected CSF rhinorrhoea Gd-DTPA enhanced MR cisternography detected 5 CSF fistulae. In 3 of 5 CSF leaks were located in the cribriform plate and in 2 of 5 sphenoidal. Whereas 4 of these depicted leaks were confirmed surgically, in 1 case the CSF fistula closed spontaneously. In another case, CSF leakage after severe head injury was clinically highly suspected but ceased prior to MR cisternography with inability to detect the temporary fistula. In the remaining 4 patients with serous rhinorrhoea MR cisternography did not provide any evidences for CSF fistulae. Intrathecal Gd-DTPA injection was tolerated excellently. Clinical and EEG examinations showed no gross behavioural or neurological disturbances and no seizure activity, respectively. The MR cisternography after intrathecal administration of Gd-DTPA represents a safe, promising and minimally invasive method for detection of CSF fistulae. This MR investigation provides excellent depiction of CSF spaces and pinpoints CSF fistulae. (orig.)

  1. Clinical Proton MR Spectroscopy in Central Nervous System Disorders

    Science.gov (United States)

    Alger, Jeffry R.; Barker, Peter B.; Bartha, Robert; Bizzi, Alberto; Boesch, Chris; Bolan, Patrick J.; Brindle, Kevin M.; Cudalbu, Cristina; Dinçer, Alp; Dydak, Ulrike; Emir, Uzay E.; Frahm, Jens; González, Ramón Gilberto; Gruber, Stephan; Gruetter, Rolf; Gupta, Rakesh K.; Heerschap, Arend; Henning, Anke; Hetherington, Hoby P.; Howe, Franklyn A.; Hüppi, Petra S.; Hurd, Ralph E.; Kantarci, Kejal; Klomp, Dennis W. J.; Kreis, Roland; Kruiskamp, Marijn J.; Leach, Martin O.; Lin, Alexander P.; Luijten, Peter R.; Marjańska, Małgorzata; Maudsley, Andrew A.; Meyerhoff, Dieter J.; Mountford, Carolyn E.; Nelson, Sarah J.; Pamir, M. Necmettin; Pan, Jullie W.; Peet, Andrew C.; Poptani, Harish; Posse, Stefan; Pouwels, Petra J. W.; Ratai, Eva-Maria; Ross, Brian D.; Scheenen, Tom W. J.; Schuster, Christian; Smith, Ian C. P.; Soher, Brian J.; Tkáč, Ivan; Vigneron, Daniel B.; Kauppinen, Risto A.

    2014-01-01

    A large body of published work shows that proton (hydrogen 1 [1H]) magnetic resonance (MR) spectroscopy has evolved from a research tool into a clinical neuroimaging modality. Herein, the authors present a summary of brain disorders in which MR spectroscopy has an impact on patient management, together with a critical consideration of common data acquisition and processing procedures. The article documents the impact of 1H MR spectroscopy in the clinical evaluation of disorders of the central nervous system. The clinical usefulness of 1H MR spectroscopy has been established for brain neoplasms, neonatal and pediatric disorders (hypoxia-ischemia, inherited metabolic diseases, and traumatic brain injury), demyelinating disorders, and infectious brain lesions. The growing list of disorders for which 1H MR spectroscopy may contribute to patient management extends to neurodegenerative diseases, epilepsy, and stroke. To facilitate expanded clinical acceptance and standardization of MR spectroscopy methodology, guidelines are provided for data acquisition and analysis, quality assessment, and interpretation. Finally, the authors offer recommendations to expedite the use of robust MR spectroscopy methodology in the clinical setting, including incorporation of technical advances on clinical units. © RSNA, 2014 Online supplemental material is available for this article. PMID:24568703

  2. Assessment of resectability of pancreatic cancer with dynamic contrast-enhanced MR imaging: technique, surgical correlation and patient outcome

    International Nuclear Information System (INIS)

    Spencer, J.A.; Ward, J.; Guthrie, J.A.; Robinson, P.J.A.; Guillou, P.J.

    1998-01-01

    The aim of our work was to investigate the use of a dynamic contrast-enhanced MR (DCEMR) technique for staging apparently localised pancreatic cancer, and to determine the patterns of tumour and vascular enhancement with this technique. Thirty-five consecutive patients were examined. The MR findings were correlated with surgical findings in 13 patients and with clinical outcome in 22 patients. Breath-hold gradient-echo fast low angle shot (TR = 100, TE = 4, flip angle 80 ) acquisitions were obtained at 10 and 40 s (right anterior coronal oblique plane) and at 90 s (axial plane) following intravenous gadolinium. Mean contrast-to-noise ratio was higher on the first than the second acquisition (p < 0.001) and higher on the second acquisition than the third (p < 0.005). Tumour conspicuity was greatest and arterial anatomy was best demonstrated on the first acquisition and the portal venous anatomy on the second. Small tumours were isointense by the third acquisition. Maximal intensity projections were helpful. The MR findings correctly predicted the surgical findings in 11 of 13 cases (85 %) and the clinical course in the other 22 patients. The DCEMR imaging technique is valuable in the staging of patients with pancreatic cancer. Capillary and portal venous phase images are both required for complete local staging. (orig.)

  3. Von Mr Classic zu Mr Nerd: Wie Forschende soziale Medien nutzen

    Directory of Open Access Journals (Sweden)

    Doreen Siegfried

    2014-12-01

    Full Text Available Unter Wissenschaftlerinnen und Wissenschaftlern lassen sich vier Typen differenzieren, die ein signifikant unterschiedliches Verhalten in ihrer Nutzung und ihrer Einstellung gegenüber Social-Web-Anwendungen zeigen: Ms Maker, Mr Tech, Mr Classic und Mr Nerd. Grundlage für die Identifizierung dieser Social-Media-Typen ist die Auswertung von 778 Online-Fragebögen, die von Anfang September bis Mitte Oktober 2013 erhoben wurden. Erfragt wurde die Nutzung von Social-Media-Instrumenten für die tägliche Arbeit in Forschung, Lehre, Administration und Wissenschaftskommunikation. Neben Intensität und Kontext der Nutzung von Web-2.0-Diensten wurden auch die Gründe für Nutzung bzw. Nicht-Nutzung einzelner Kanäle sowie generelle Einstellungen gegenüber Social-Media-Werkzeugen erfragt. Among scientists, four types of personality can be identified whose usage and attitude towards social web applications show significant variations: Ms Maker, Mr Tech, Mr Classic and Mr Nerd. This typification is based on 778 online questionnaires received between September and October 2013. The survey sampled the usage of social media tools for daily routines in research, teaching, administrative work and scholarly communication. The survey asked questions about the intensity and the context in which Web 2.0 services are used, about the reasons for (not using certain channels, and about general attitudes towards social media tools.

  4. Thick brane in f(R) gravity with Palatini dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bazeia, D.; Losano, L. [Universidade Federal da Paraiba, Departamento de Fisica, Joao Pessoa, PB (Brazil); Menezes, R. [Universidade Federal da Paraiba, Departamento de Ciencias Exatas, Rio Tinto, PB (Brazil); Universidade Federal de Campina Grande, Departamento de Fisica, Campina Grande, PB (Brazil); Olmo, Gonzalo J. [Universidade Federal da Paraiba, Departamento de Fisica, Joao Pessoa, PB (Brazil); Universidad de Valencia, Departamento de Fisica Teorica, IFIC, Centro Mixto Universidad de Valencia-CSIC, Burjassot, Valencia (Spain); Rubiera-Garcia, D. [Universidade Federal da Paraiba, Departamento de Fisica, Joao Pessoa, PB (Brazil); Universidade de Lisboa, Faculdade de Ciencias, Instituto de Astrofisica e Ciencias do Espaco, Lisbon (Portugal); Fudan University, Department of Physics, Center for Field Theory and Particle Physics, Shanghai (China)

    2015-12-15

    This work deals with modified gravity in five-dimensional space-time. We study a thick Palatini f(R) brane, that is, a braneworld scenario described by an anti-de Sitter warped geometry with a single extra dimension of infinite extent, sourced by a real scalar field under the Palatini approach, where the metric and the connection are regarded as independent degrees of freedom. We consider a first-order framework which we use to provide exact solutions for the scalar field and warp factor. We also investigate a perturbative scenario such that the Palatini approach is implemented through a Lagrangian f(R) = R + εR{sup n}, where the small parameter ε controls the deviation from the standard thick brane case. In both cases it is found that the warp factor tends to localize the extra dimension due to the nonlinear corrections. (orig.)

  5. Usefulness of high helical pitch acquisition for reduction of patient radiation dose in cardiac multidetector computed tomography

    International Nuclear Information System (INIS)

    Sano, Tomonari; Matsutani, Hideyuki; Kondo, Takeshi; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi

    2009-01-01

    Helical pitch (HP) usually has been decided automatically by the software (Heart Navi) included in the MDCT machine (Aquilion 64) depending on gantry rotation speed (r) and heart rate (HR). To reduce radiation dose, 255 consecutive patients with low HR (≤60 bpm) and without arrhythmia underwent cardiac MDCT using high HP. We had already reported that the relationship among r, HP, and the maximum data acquisition time interval (Tmax) does not create the data deficit in arrhythmia. It was represented as Tmax=(69.88/HP-0.64) r; (equation 1). From equation 1, HP=69.88 r/(Tmax+0.64 r); (equation 2) was derived. We measured the maximum R-R interval (R-Rmax) on electrocardiogram (ECG) before multi detector row CT (MDCT) acquisition, and R-Rmax x 1.1 was calculated as Tmax in consideration of R-Rmax prolongation during MDCT acquisition. The HP of high HP acquisition was calculated from equation 2. In HR≤50 bpm, Heart Navi determined r: 0.35 sec/rot and HP: 9.8, and in 51 bpm≤HR≤66 bpm, r:0.35 sec/rot and HP: 11.2. HP of the high HP (16.4±1.2) was significantly (p<0.0001) higher than that of Heart Navi HP (10.9±0.6). The scanning time (6.5±0.6 sec) of high HP was significantly (p<0.0001) shorter than that of Heart Navi (9.0±0.8 sec), and the dose length product of high HP (675±185 mGy·cm) was significantly (p<0.0001) lower than that of Heart Navi (923±252 mGy·cm). The high HP could produce fine images in 251/255 patients. In conclusion, the high HP acquisition is useful for reduction of radiation dose and scanning time. (author)

  6. M.R. imaging of spinal disorders

    International Nuclear Information System (INIS)

    Akino, Minoru; Isu, Toyohiko; Iwasaki, Yoshinobu; Abe, Hiroshi; Abe, Satoru; Miyasaka, Kazuo; Nomura, Mikio; Saito, Hisatoshi.

    1987-01-01

    In many papers about the M.R. imaging of spinal disorders, almost all the diagnoses have been carried out using only the sagittal image. However, we ourselves have thus for diagnosed about 500 cases of spinal disorders using the resistive type of MRI (0.15 T). On the basis of our experience, we have established two main principles as regards the MRI diagnosis of spinal disorders: 1) a surface coil must be used in the diagnosis of spinal disorders, and 2) diagnosis must be carried out by the use of both sagittal and axial images. We present some typical cases of spinal disorders in this paper. From these cases, we see that MRI has advantages and disadvantages as regards the diagnosis of spinal disorders compared with X-ray diagnostic apparatus. The first advantageous point is that we can directly obtain an image of the spinal cord without the intrathecal injection of a contrast material. The second point is that MRI can avoid the bone artifacts which often occur when using the X-ray CT; moreover, there is none of the hazard connected with the use of X-rays. The biggest disadvantage is that the spatial resolution of the resistive type of MRI is slightly inferior to that of the high-resolutional X-ray CT. The second disadvantage is that the ability to detect an ossificative process, such as disc disease or OPLL, is very restricted because of the low signal intensity from the cortical bone. We propose two points for the improvement of the MR imaging of spinal disorders. One is the production of a high-sensitivity surface coil. The other is the application of Gd-DTPA, which is thought to have a high potential to detect spinal disorders. If we can realize these points, the images of spinal disorders produced by the resistive type of MRI will be clearer and more informative. (J.P.N.)

  7. Physical attributes of anisotropic compact stars in f(R, G) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Shamir, M.F.; Zia, Saeeda [National University of Computer and Emerging Sciences, Department of Sciences and Humanities, Lahore (Pakistan)

    2017-07-15

    Modified gravity is one of the potential candidates to explain the accelerated expansion of the universe. Current study highlights the materialization of anisotropic compact stars in the context of f(R, G) theory of gravity. In particular, to gain insight in the physical behavior of three stars namely, Her X1, SAX J 1808-3658 and 4U 1820-30, energy density, and radial and tangential pressures are calculated. The f(R, G) gravity model is split into a Starobinsky like f(R) model and a power law f(G) model. The main feature of the work is a 3-dimensional graphical analysis in which, anisotropic measurements, energy conditions and stability attributes of these stars are discussed. It is shown that all three stars behave as usual for positive values of the f(G) model parameter n. (orig.)

  8. SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lim, T; Wang, J; Frank, S; Stafford, R; Bruno, T; Bathala, T; Mahmood, U; Pugh, T; Ibbott, G; Kudchadker, R [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3

  9. SU-E-J-214: MR Protocol Development to Visualize Sirius MRI Markers in Prostate Brachytherapy Patients for MR-Based Post-Implant Dosimetry

    International Nuclear Information System (INIS)

    Lim, T; Wang, J; Frank, S; Stafford, R; Bruno, T; Bathala, T; Mahmood, U; Pugh, T; Ibbott, G; Kudchadker, R

    2015-01-01

    Purpose: The current CT-based post-implant dosimetry allows precise seed localization but limited anatomical delineation. Switching to MR-based post-implant dosimetry is confounded by imprecise seed localization. One approach is to place positive-contrast markers (Sirius) adjacent to the negative-contrast seeds. This patient study aims to assess the utility of a 3D fast spoiled gradient-recalled echo (FSPGR) sequence to visualize Sirius markers for post-implant dosimetry. Methods: MRI images were acquired in prostate implant patients (n=10) on Day 0 (day-of-implant) and Day 30. The post-implant MR protocol consisted of 3D T2-weighted fast-spin-echo (FSE), T2-weighted 2D-FSE (axial) and T1-weighted 2D-FSE (axial/sagittal/coronal). We incorporated a 3D-FSPGR sequence into the post-implant MR protocol to visualize the Sirius markers. Patients were scanned with different number-of-excitations (6, 8, 10), field-of-view (10cm, 14cm, 18cm), slice thickness (1mm, 0.8mm), flip angle (14 degrees, 20 degrees), bandwidth (122.070 Hz/pixel, 325.508 Hz/pixel, 390.625 Hz/pixel), phase encoding steps (160, 192, 224, 256), frequency-encoding direction (right/left, anterior/posterior), echo-time type (minimum-full, out-of-phase), field strength (1.5T, 3T), contrast (with, without), scanner vendor (Siemens, GE), coil (endorectal-coil only, endorectal-and-torso-coil, torsocoil only), endorectal-coil filling (30cc, 50cc) and endorectal-coil filling type (air, perfluorocarbon [PFC]). For post-implant dosimetric evaluation with greater anatomical detail, 3D-FSE images were fused with 3D-FSPGR images. For comparison with CT-based post-implant dosimetry, CT images were fused with 3D-FSPGR images. Results: The 3D-FSPGR sequence facilitated visualization of markers in patients. Marker visualization helped distinguish signal voids as seeds versus needle tracks for more definitive MR-based post-implant dosimetry. On the CT-MR fused images, the distance between the seed on CT to MR images was 3

  10. ACP/R3000 processors in data acquisition systems

    International Nuclear Information System (INIS)

    Deppe, J.; Areti, H.; Atac, R.

    1989-02-01

    We describe ACP/R3000 processor based data acquisition systems for high energy physics. This VME bus compatible processor board, with a computational power equivalent to 15 VAX 11/780s or better, contains 8 Mb of memory for event buffering and has a high speed secondary bus that allows data gathering from front end electronics. 2 refs., 3 figs

  11. MR sialography: evaluation of an ultra-fast sequence in consideration of a parallel acquisition technique and different functional conditions in patients with salivary gland diseases

    International Nuclear Information System (INIS)

    Petridis, C.; Ries, T.; Cramer, M.C.; Graessner, J.; Petersen, K.U.; Reitmeier, F.; Jaehne, M.; Weiss, F.; Adam, G.; Habermann, C.R.

    2007-01-01

    Purpose: To evaluate an ultra-fast sequence for MR sialography requiring no post-processing and to compare the acquisition technique regarding the effect of oral stimulation with a parallel acquisition technique in patients with salivary gland diseases. Materials and Methods: 128 patients with salivary gland disease were prospectively examined using a 1.5-T superconducting system with a 30 mT/m maximum gradient capability and a maximum slew rate of 125 mT/m/sec. A single-shot turbo-spin-echo sequence (ss-TSE) with an acquisition time of 2.8 sec was used in transverse and oblique sagittal orientation. All images were obtained with and without a parallel imaging technique. The evaluation of the ductal system of the parotid and submandibular gland was performed using a visual scale of 1-5 for each side. The images were assessed by two independent experienced radiologists. An ANOVA with posthoc comparisons and an overall two tailed significance level of p=0.05 was used for the statistical evaluation. An intraclass correlation was computed to evaluate interobserver variability and a correlation of >0.8 was determined, thereby indicating a high correlation. Results: Depending on the diagnosed diseases and the absence of abruption of the ducts, all parts of excretory ducts were able to be visualized in all patients using the developed technique with an overall rating for all ducts of 2.70 (SD±0.89). A high correlation was achieved between the two observers with an intraclass correlation of 0.73. Oral application of a sialogogum improved the visibility of excretory ducts significantly (p<0.001). In contrast, the use of a parallel imaging technique led to a significant decrease in image quality (p=0,011). (orig.)

  12. Portfolio Purchasing Decision for Mobile Power Equipment of B2C E-Commerce Export Retailer Based on CVaR

    Science.gov (United States)

    Yanchun, Wan; Qiucen, Chen

    2017-11-01

    Purchasing is an important part of export e-commerce of B2C, which plays an important role on risk and cost control in supply management. From the perspective of risk control, the paper construct a CVaR model for portfolio purchase. We select a heavy sales mobile power equipment from a typical B2C e-commerce export retailer as study sample. This study optimizes the purchasing strategy of this type of mobile power equipment. The research has some reference for similar enterprises in purchasing portfolio decision.

  13. Evaluation of renal transplants with Gd-DOTA dynamic MR imaging with factor analysis

    International Nuclear Information System (INIS)

    Chabrials, J.; Frouin, F.; Helenon, O.; Benall, H.; Kreis, H.; Moreau, J.F.; Di Paola, R.

    1990-01-01

    This paper reports on renal and urinary excretion factors by means of Gd-DOTA dynamic MR imaging and using factor analysis of dynamic structure (FADS) to follow-up renal transplants. We examined 60 patients with renal transplants by use of dynamic MR imaging after administration of a Gd-DOTA bolus (0.2 ml/kg) on a 0.5-T system; 10--12 fast gradient-echo sequences (TR/TE = 40/14, flip angle = 45 degree, acquisition time = 13 seconds) with single images and a 32-second intersequence delay were used. Of these, 13 dynamic MR imaging sequences were processed with an extension to dynamic MR images of FADS, previously developed to analyze nuclear medicine dynamic studies. The results were compared with the results of biologic dosages, renal biopsy and Seldinger digital arteriography

  14. Pancreatic adenocarcinoma: combination of MR imaging, MR angiography and MR cholangiopancreatography for the diagnosis and assessment of resectability

    International Nuclear Information System (INIS)

    Catalano, C.; Pavone, P.; Laghi, A.; Panebianco, V.; Scipioni, A.; Fanelli, F.; Brillo, R.; Passariello, R.

    1998-01-01

    The purpose of this study was to determine the possibility of integrating MR cholangiopancreatography (MRCP) and MR angiography (MRA) to conventional MR images in the diagnosis and assessment of resectability of pancreatic adenocarcinoma. Twenty-three patients with pancreatic adenocarcinoma were prospectively examined with MR. Conventional MR images were acquired in all patients. Three-dimensional MRCP and MRA images were acquired in all patients with suspected biliary and vascular involvement. Acquisition time was less than 45 min in all cases. Images were independently evaluated by two radiologists, with final reading decided by consensus among readers. Diagnosis was confirmed with surgery in 16 patients and with percutaneous biopsy in 7. Concordance among readers was high with a kappa value of 0.83. Pancreatic adenocarcinoma was observed in all patients. Correct assessment of unresectability due to vascular involvement was found in 22 of 23 patients. Biliary obstruction was evident in 13 patients, involving the biliary and pancreatic ducts in 9 and the biliary ducts only in 4. Technical advances permit extensive use of MRI in the evaluation of abdominal pathologies. The combination of MR imaging, MRCP, and MRA can provide sufficient information for the diagnosis and assessment of resectability of pancreatic adenocarcinoma, which otherwise would require three different exams. (orig.)

  15. MR angiography of the carotid arteries in 3 D TOF-technique with sagittal ''double-slab'' acquisition using a new head-neck coil

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Heller, M.

    1996-01-01

    Purpose: The aim of the study was to assess the value of MR angiography (MRA) in sagittal technique compared to DSA in the evaluation of carotid artery stenosis. Methods: 80 Carotid arteries in 40 symptomatic patients were prospectively studied with DSA and MRA. MRA was carried out by means of 3D time-of-flight technique with a FISP sequence (T E 6 ms/T R 80 ms, flip angle 25 , FOV 240x210 mm, matrix 157x256 mm, in-plane resolution 1.34x0.94 mm, partition thickness 1.32 mm, slab thickness 45 mm, acquisition time 7 min) using a new head-neck coil. Data acquisition was performed in sagittal orientation with the 'double-slab' technique. Imaging quality of the extracranial carotid arteries and correctness of quantification of stenosis was performed. Results: Imaging quality was good at the origin of the carotid arteries in 65%, at the bifurcation region in 98% and near the skull base in 81%. The agreement of DSA and MRA was 96% of the normal arteries (24/25), 90% of the severe stenoses (28/31) and 100% of the occluded arteries (9/9). Conclusion: MRA in sagittal 'double-slab' technique is a noninvasive technique allowing to detect normal arteries and candidates for surgery with high degree of certainity. (orig.) [de

  16. PET/MR in oncology: an introduction with focus on MR and future perspectives for hybrid imaging

    Science.gov (United States)

    Balyasnikova, Svetlana; Löfgren, Johan; de Nijs, Robin; Zamogilnaya, Yanna; Højgaard, Liselotte; Fischer, Barbara M

    2012-01-01

    After more than 20 years of research, a fully integrated PET/MR scanner was launched in 2010 enabling simultaneous acquisition of PET and MR imaging. Currently, no clinical indication for combined PET/MR has been established, however the expectations are high. In this paper we will discuss some of the challenges inherent in this new technology, but focus on potential applications for simultaneous PET/MR in the field of oncology. Methods and tracers for use with the PET technology will be familiar to most readers of this journal; thus this paper aims to provide a short and basic introduction to a number of different MRI techniques, such as DWI-MR (diffusion weighted imaging MR), DCE-MR (dynamic contrast enhanced MR), MRS (MR spectroscopy) and MR for attenuation correction of PET. All MR techniques presented in this paper have shown promising results in the treatment of patients with solid tumors and could be applied together with PET increasing the amount of information about the tissues of interest. The potential clinical benefit of applying PET/MR in staging, radiotherapy planning and treatment evaluation in oncology, as well as the research perspectives for the use of PET/MR in the development of new tracers and drugs will be discussed. PMID:23145362

  17. Visit of H.E. Mr. Attila Chikan, Minister of Economic Affairs, Prof. Adam Török, President, National Committee for Technological Development, Mr. Pal Koncz, Deputy Director General, National Committee for Technological Development, Hungary

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    Visit of H.E. Mr. Attila Chikan, Minister of Economic Affairs, Prof. Adam Török, President, National Committee for Technological Development, Mr. Pal Koncz, Deputy Director General, National Committee for Technological Development, Hungary

  18. rändrat omhändertagande av patienter med uretärsten : - Lärdomar från ett förbättringsarbete

    OpenAIRE

    Khatami, Annelie

    2014-01-01

    Bakgrund: Omkring 10-15 % av befolkningen, oftast i arbetsför ålder, riskerar att någon gång drabbas av njursten. Nationella riktlinjer för njurstensbehandling saknas, men studier stödjer behandling inom 48 timmar för snabb symtomlindring och minskade besvärr patienten. Inom studerad verksamhet var tiden från diagnos till behandling lång och återinläggningarna var många, varför ett förbättringsarbete initierades. Syfte: Syftet med förbättringsarbetet var att halvera tiden från diagnos till...

  19. Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection.

    Science.gov (United States)

    O'Halloran, Rafael L; Holmes, James H; Wu, Yu-Chien; Alexander, Andrew; Fain, Sean B

    2010-01-01

    An undersampled diffusion-weighted stack-of-stars acquisition is combined with iterative highly constrained back-projection to perform hyperpolarized helium-3 MR q-space imaging with combined regional correction of radiofrequency- and T1-related signal loss in a single breath-held scan. The technique is tested in computer simulations and phantom experiments and demonstrated in a healthy human volunteer with whole-lung coverage in a 13-sec breath-hold. Measures of lung microstructure at three different lung volumes are evaluated using inhaled gas volumes of 500 mL, 1000 mL, and 1500 mL to demonstrate feasibility. Phantom results demonstrate that the proposed technique is in agreement with theoretical values, as well as with a fully sampled two-dimensional Cartesian acquisition. Results from the volunteer study demonstrate that the root mean squared diffusion distance increased significantly from the 500-mL volume to the 1000-mL volume. This technique represents the first demonstration of a spatially resolved hyperpolarized helium-3 q-space imaging technique and shows promise for microstructural evaluation of lung disease in three dimensions. Copyright (c) 2009 Wiley-Liss, Inc.

  20. Static spherically symmetric wormholes in f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Zubair, M.; Ahmad, Yasir [Institute Of Information Technology, Department of Mathematics, COMSATS, Lahore (Pakistan); Waheed, Saira [Prince Mohammad Bin Fahd University, Al Khobar (Saudi Arabia)

    2016-08-15

    In this work, we explore wormhole solutions in f(R, T) theory of gravity, where R is the scalar curvature and T is the trace of stress-energy tensor of matter. To investigate this, we consider a static spherically symmetric geometry with matter contents as anisotropic, isotropic, and barotropic fluids in three separate cases. By taking into account the Starobinsky f(R) model, we analyze the behavior of energy conditions for these different kinds of fluids. It is shown that the wormhole solutions can be constructed without exotic matter in few regions of space-time. We also give the graphical illustration of the results obtained and discuss the equilibrium picture for the anisotropic case only. It is concluded that the wormhole solutions with anisotropic matter are realistic and stable in this theory of gravity. (orig.)

  1. 78 FR 15015 - Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction

    Science.gov (United States)

    2013-03-08

    ... FEDERAL RESERVE SYSTEM Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction This notice corrects a notice (FR Doc. 2013-03831) published on page 11884 of the issue for Wednesday, February 20, 2013. Under the Federal Reserve Bank of San Francisco heading, the entry for One PacificCoast Foundation and One PacificCoast...

  2. Fast and ultrafast MR-imaging of the heart

    International Nuclear Information System (INIS)

    Schulthess, G.K. von; Davis, C.P.; Debatin, J.F.; McKinnon, G.C.

    1995-01-01

    MRI has been hampered by long image acquisition times. This combined with its non-realtime nature and the limited spatial resolution has made it difficult to extend MRT to the study of small cardiac structures. Recent technical improvements have made breath-held or realtime MRI feasible and thus laid the foundations for further applications in the field of cardiovascular imaging, notably MR coronary angiography, imaging of cardiac valve leaflets, as well as firstpass perfusion studies. Moreover ultrafast MR techniques may eventually replace conventional data acquisition strategies and thus drastically increase patient throughput by shortening acquisition time. This article provides an overview of the technical advances in MRI and their application to the cardiovascular system and discusses possibilities of combined ultrafast and interventional strategies. (orig.) [de

  3. 1. What is E-Commerce?

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 10. Electronic Commerce - What is E-Commerce? V Rajaraman. Series Article Volume 5 Issue 10 October 2000 pp 13-23 ... Author Affiliations. V Rajaraman1. IBM Professor of Information Technology, JNCASR, Bangalore 560 064, India.

  4. Power-law cosmic expansion in f(R) gravity models

    International Nuclear Information System (INIS)

    Goheer, Naureen; Larena, Julien; Dunsby, Peter K. S.

    2009-01-01

    We show that within the class of f(R) gravity theories, Friedmann-Lemaitre-Robertson-Walker power-law perfect fluid solutions only exist for R n gravity. This significantly restricts the set of exact cosmological solutions which have similar properties to what is found in standard general relativity.

  5. 78 FR 63476 - Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction

    Science.gov (United States)

    2013-10-24

    ... FEDERAL RESERVE SYSTEM Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction This notice corrects a notice (FR Doc. 2013-24511) published on page 62363 of the issue for Monday, October 21, 2013. Under the Federal Reserve Bank of Dallas heading, the entry for WCM-Parkway, Ltd, Dallas, Texas, is revised to read as...

  6. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients—Current state of image quality

    International Nuclear Information System (INIS)

    Schwenzer, N.F.; Stegger, L.; Bisdas, S.; Schraml, C.; Kolb, A.; Boss, A.; Müller, M.

    2012-01-01

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [ 18 F]-FDG, [ 11 C]-methionine or [ 68 Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [ 11 C]-methionine and [ 68 Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 ± 0.54; FLAIR: 1.38 ± 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 ± 0.69; ASL: 1.10 ± 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [ 11 C]-methionine; additional lesions were found in 2/8 [ 68 Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 ± 2.2% vs. 0.9 ± 3.6%; mean ratio (frontal/parieto-occipital) 0.93 ± 0.08 vs. 0.96 ± 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance of PET results between PET/MR and PET

  7. Simultaneous PET/MR imaging in a human brain PET/MR system in 50 patients-Current state of image quality

    Energy Technology Data Exchange (ETDEWEB)

    Schwenzer, N.F., E-mail: nina.schwenzer@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Stegger, L., E-mail: stegger@gmx.net [Department of Nuclear Medicine and European Institute for Molecular Imaging, University of Muenster, Muenster (Germany); Bisdas, S., E-mail: sbisdas@gmail.com [Department of Diagnostic and Interventional Neuroradiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Schraml, C., E-mail: christina.schraml@med.uni-tuebingen.de [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Kolb, A., E-mail: armin.kolb@med.uni-tuebingen.de [Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Preclinical Imaging and Radiopharmacy, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Boss, A., E-mail: Andreas.Boss@usz.ch [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); Institute of Diagnostic and Interventional Radiology, University Hospital Zuerich, Zuerich (Switzerland); Mueller, M., E-mail: mark.mueller@med.uni-tuebingen.de [Department of Nuclear Medicine, Eberhard-Karls University Tuebingen, Tuebingen (Germany); and others

    2012-11-15

    Objectives: The present work illustrates the current state of image quality and diagnostic accuracy in a new hybrid BrainPET/MR. Materials and methods: 50 patients with intracranial masses, head and upper neck tumors or neurodegenerative diseases were examined with a hybrid BrainPET/MR consisting of a conventional 3T MR system and an MR-compatible PET insert. Directly before PET/MR, all patients underwent a PET/CT examination with either [{sup 18}F]-FDG, [{sup 11}C]-methionine or [{sup 68}Ga]-DOTATOC. In addition to anatomical MR scans, functional sequences were performed including diffusion tensor imaging (DTI), arterial spin labeling (ASL) and proton-spectroscopy. Image quality score of MR imaging was evaluated using a 4-point-scale. PET data quality was assessed by evaluating FDG-uptake and tumor delineation with [{sup 11}C]-methionine and [{sup 68}Ga]-DOTATOC. FDG uptake quantification accuracy was evaluated by means of ROI analysis (right and left frontal and temporo-occipital lobes). The asymmetry indices and ratios between frontal and occipital ROIs were compared. Results: In 45/50 patients, PET/MR examination was successful. Visual analysis revealed a diagnostic image quality of anatomical MR imaging (mean quality score T2 FSE: 1.27 {+-} 0.54; FLAIR: 1.38 {+-} 0.61). ASL and proton-spectroscopy was possible in all cases. In DTI, dental artifacts lead to one non-diagnostic dataset (mean quality score DTI: 1.32 {+-} 0.69; ASL: 1.10 {+-} 0.31). PET datasets of PET/MR and PET/CT offered comparable tumor delineation with [{sup 11}C]-methionine; additional lesions were found in 2/8 [{sup 68}Ga]-DOTATOC-PET in the PET/MR. Mean asymmetry index revealed a high accordance between PET/MR and PET/CT (1.5 {+-} 2.2% vs. 0.9 {+-} 3.6%; mean ratio (frontal/parieto-occipital) 0.93 {+-} 0.08 vs. 0.96 {+-} 0.05), respectively. Conclusions: The hybrid BrainPET/MR allows for molecular, anatomical and functional imaging with uncompromised MR image quality and a high accordance

  8. Contrast-enhanced dynamic MR nephrography using the TurboFLASH navigator-gating technique in children

    International Nuclear Information System (INIS)

    Boss, Andreas; Schaefer, Juergen F.; Claussen, Claus D.; Kueper, Klaus; Schlemmer, Heinz-Peter; Martirosian, Petros; Schick, Fritz; Hacker, Hans-Walter; Darge, Kassa

    2006-01-01

    The purpose of this work was to test the feasibility of an MR examination protocol for the comprehensive assessment of renal morphology, excretion and split renal function using a navigator-gated TurboFLASH sequence. A navigator-gated T1-weighted single-slice TurboFLASH sequence suitable for dynamic MR urography and nephrography was implemented. A protocol was developed allowing for assessment of urinary excretion and split renal function by recording the renal clearance of a gadolinium (Gd) diethylene-triamine-pentacetic-acid (DTPA) bolus. Ten patients aged between 14 months and 14 years (mean age 4.8±4.6 years) were evaluated with the following indications: pelvicalyceal dilatation (n=4), follow-up after pyeloplasty (n=1), duplex systems (n=3), large renal cyst (n=1), and renal insufficiency (n=1). Dynamic MR urography and MR split renal function were compared to MAG3 scintigraphy. Evaluation of morphology, excretion and function required 50-60 minutes examination time, plus 10 minutes for post-processing. The TurboFLASH sequence yielded image acquisition at nearly identical diaphragm positions allowing for accurate region-of-interest evaluation within the renal parenchyma and the urinary passage. Static and dynamic MR urography showed the morphology of the urinary tract and excretion with sufficient diagnostic imaging quality, and the results were in diagnostic compliance with scintigraphy. MRI and scintigraphy yielded similar results for split renal function with a correlation coefficient of R=0.968 determined by linear regression. Our conclusions were that the method is robust, easy to perform on a clinical 1.5 T MRI system, rapid to evaluate and post-process and, therefore, easy to incorporate into clinical routine. Compared to scintigraphy, the higher spatial resolution of the MR examination provides additional important information improving the management of the pediatric patients without the application of radioactive tracers. (orig.)

  9. Utilizing Information Technology to Facilitate Rapid Acquisition

    Science.gov (United States)

    2006-06-01

    PAGES 109 14. SUBJECT TERMS Rapid Acquisition, eCommerce , eProcurement, Information Technology, Contracting, Global Information Network...Agency. 5 eCommerce and eProcurement, and possess an adequate knowledge of information technology. D. RESEARCH QUESTIONS 1. Primary Research... eCommerce , Information Technology, and eProcurement knowledge, and government and private industry reports utilizing numerous library and Internet

  10. Partial pressure (or fugacity) of carbon dioxide, dissolved inorganic carbon, pH, alkalinity, temperature, salinity and other variables collected from discrete sample and profile observations using Alkalinity titrator, CTD and other instruments from the KNORR in the South Pacific Ocean from 2005-08-21 to 2005-10-06 (NODC Accession 0108071)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NODC Accession 0108071 includes chemical, discrete sample, physical and profile data collected from KNORR in the South Pacific Ocean from 2005-08-21 to 2005-10-06...

  11. MR study of acute myocardial infarction with injection of Gd-DOTA (Fifteen patients)

    International Nuclear Information System (INIS)

    Richoz, B.; Delcour, C.; Depelchin, P.; Lenaers, A.; Jacquemin, C.; Gusella, P.; Struyven, J.; Richoz, B.

    1990-01-01

    We studied 15 patients 4 to 8 days after myocardial infarction by using ECG gated MR before and after administration of 0.2 mmol/kg Gd-DOTA. The diagnosis in each patient was confirmed by electrocardiographic criteria, elevated levels of fractionated creatine kinase (CK) isoenzyme, thallium scintigraphy, ventriculography and coronarography. T1-weighted, spin-echo images, were obtained before and immediately after injection of Gd-DOTA and were repeated 15 min later. The site of infarction was visualized in 10 patients as an area of high signal intensity after the injection of Gd-DOTA. Contrast between normal and infarcted myocardium was greatest 15 min after injection. Three patients were excluded because of failure to acquire adequate MR studies. In 2 other patients, the infarct were not detected. Before injection of Gd-DOTA, only 2 infarcts were detected. These results suggest that Gd-DOTA can improve MR visualization and detection of acute myocardial infarction [fr

  12. The simplest non-minimal matter-geometry coupling in the f(R, T) cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, P.H.R.S. [ITA - Instituto Tecnologico de Aeronautica, Departamento de Fisica, Sao Paulo (Brazil); Sahoo, P.K. [Birla Institute of Technology and Science-Pilani, Department of Mathematics, Hyderabad (India)

    2017-07-15

    f(R, T) gravity is an extended theory of gravity in which the gravitational action contains general terms of both the Ricci scalar R and the trace of the energy-momentum tensor T. In this way, f(R, T) models are capable of describing a non-minimal coupling between geometry (through terms in R) and matter (through terms in T). In this article we construct a cosmological model from the simplest non-minimal matter-geometry coupling within the f(R, T) gravity formalism, by means of an effective energy-momentum tensor, given by the sum of the usual matter energy-momentum tensor with a dark energy contribution, with the latter coming from the matter-geometry coupling terms. We apply the energy conditions to our solutions in order to obtain a range of values for the free parameters of the model which yield a healthy and well-behaved scenario. For some values of the free parameters which are submissive to the energy conditions application, it is possible to predict a transition from a decelerated period of the expansion of the universe to a period of acceleration (dark energy era). We also propose further applications of this particular case of the f(R, T) formalism in order to check its reliability in other fields, rather than cosmology. (orig.)

  13. The simplest non-minimal matter-geometry coupling in the f(R, T) cosmology

    International Nuclear Information System (INIS)

    Moraes, P.H.R.S.; Sahoo, P.K.

    2017-01-01

    f(R, T) gravity is an extended theory of gravity in which the gravitational action contains general terms of both the Ricci scalar R and the trace of the energy-momentum tensor T. In this way, f(R, T) models are capable of describing a non-minimal coupling between geometry (through terms in R) and matter (through terms in T). In this article we construct a cosmological model from the simplest non-minimal matter-geometry coupling within the f(R, T) gravity formalism, by means of an effective energy-momentum tensor, given by the sum of the usual matter energy-momentum tensor with a dark energy contribution, with the latter coming from the matter-geometry coupling terms. We apply the energy conditions to our solutions in order to obtain a range of values for the free parameters of the model which yield a healthy and well-behaved scenario. For some values of the free parameters which are submissive to the energy conditions application, it is possible to predict a transition from a decelerated period of the expansion of the universe to a period of acceleration (dark energy era). We also propose further applications of this particular case of the f(R, T) formalism in order to check its reliability in other fields, rather than cosmology. (orig.)

  14. Encadrement des produits et des procédés : réglementation et normalisation du commerce international

    Directory of Open Access Journals (Sweden)

    Morin Odile

    2003-07-01

    Full Text Available Produits et procédés sont encadrés à la fois par des réglementations et, à un autre niveau, par des normes du commerce international. Cette présentation traite des textes réglementaires au niveau communautaire et national. On rappellera que l’entrée en vigueur d’un règlement européen est suivie d’une transposition dans le droit de chaque pays membre et que la réglementation nationale s’applique en l’absence de dispositions communautaires. En matière de commerce international, seront évoquées les actions de normalisation du Conseil Oléicole International (COI pour les huiles d’olive et de grignons d’olive et celles du Codex Alimentarius pour les huiles et graisses comestibles. L’ensemble des dispositions réglementaires constitue un cadre englobant les productions de l’amont vers l’aval, à la fois sur un plan vertical (oléagineux, huiles et corps gras, huiles d’olive, margarines, procédés de raffinage et transversalement (composés organiques volatils, OGM, solvants d’extraction, additifs, contaminants…. Le cas de l’huile d’olive est particulier en ce qu’il bénéficie d’un encadrement au niveau international (normes commerciales COI et Codex Alimentarius, européen et national (réglementation. Le Codex Alimentarius, quant à lui, établit des normes à caractère vertical (huiles végétales, graisses animales, huiles d’olive, matières grasses tartinables… et horizontal (additifs, résidus de pesticides…. L’essentiel de cet encadrement est résumé dans les tableaux qui illustrent cette contribution.

  15. 29 CFR 776.10 - Employees participating in the actual movement of commerce.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Employees participating in the actual movement of commerce... commerce. (a) Under the principles stated in § 776.9, the wage and hours provisions of the Act apply... instrumentalities and channels of interstate and foreign commerce. Similarly, employees of such businesses as...

  16. 76 FR 60494 - Formations of, Acquisitions by, and Mergers of Savings and Loan Holding Companies; Correction

    Science.gov (United States)

    2011-09-29

    ... FEDERAL RESERVE SYSTEM Formations of, Acquisitions by, and Mergers of Savings and Loan Holding Companies; Correction This notice corrects a notice (FR Doc. 2011-24388) published on page 58812 of the... with Polonia Bancorp, Inc., Baltimore, Maryland, which proposes to become a savings and loan holding...

  17. Clinical estimation of myocardial infarct volume with MR imaging

    International Nuclear Information System (INIS)

    Johns, J.A.; Leavitt, M.B.; Field, B.D.; Yasuda, T.; Gold, H.; Leinbach, R.C.; Brady, T.J.; Dinsmore, R.E.

    1987-01-01

    MR imaging has not previously been used to assess infarct size in humans. Short-axis spin-echo cardiac MR imaging was performed in 20 patients who had undergone intravenous thrombolytic therapy and angiography, 10 days after myocardial infarct. A semi-automated computer program was used to outline the infarct region on each section. The outlines were algorithmically stacked and a three-dimensional representation of the infarct was created. The MR imaging infarct volume was then computed using the Simpson rule. Comparison with ventriculographic infarct size as determined by the computed severely hypokinetic segment length showed excellent correlation (r = .84, P < .001)

  18. Compact stars in f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Das, Amit; Guha, B.K. [Indian Institute of Engineering Science and Technology, Department of Physics, Howrah, West Bengal (India); Rahaman, Farook [Jadavpur University, Department of Mathematics, Kolkata, West Bengal (India); Ray, Saibal [Government College of Engineering and Ceramic Technology, Department of Physics, Kolkata, West Bengal (India)

    2016-12-15

    In the present paper we generate a set of solutions describing the interior of a compact star under f(R, T) theory of gravity which admits conformal motion. An extension of general relativity, the f(R, T) gravity is associated to Ricci scalar R and the trace of the energy-momentum tensor T. To handle the Einstein field equations in the form of differential equations of second order, first of all we adopt the Lie algebra with conformal Killing vectors (CKV) which enable one to get a solvable form of such equations and second we consider the equation of state (EOS) p = ωρ with 0 < ω < 1 for the fluid distribution consisting of normal matter, ω being the EOS parameter. We therefore analytically explore several physical aspects of the model to represent behavior of the compact stars such as - energy conditions, TOV equation, stability of the system, Buchdahl condition, compactness and redshift. It is checked that the physical validity and the acceptability of the present model within the specified observational constraint in connection to a dozen of the compact star candidates are quite satisfactory. (orig.)

  19. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  20. Fundamentals of quantitative dynamic contrast-enhanced MR imaging.

    Science.gov (United States)

    Paldino, Michael J; Barboriak, Daniel P

    2009-05-01

    Quantitative analysis of dynamic contrast-enhanced MR imaging (DCE-MR imaging) has the power to provide information regarding physiologic characteristics of the microvasculature and is, therefore, of great potential value to the practice of oncology. In particular, these techniques could have a significant impact on the development of novel anticancer therapies as a promising biomarker of drug activity. Standardization of DCE-MR imaging acquisition and analysis to provide more reproducible measures of tumor vessel physiology is of crucial importance to realize this potential. The purpose of this article is to review the pathophysiologic basis and technical aspects of DCE-MR imaging techniques.

  1. Brane f(R) gravity and the dark side of the universe

    International Nuclear Information System (INIS)

    Borzou, A.; Sepangi, H. R.; Shahidi, S.; Yousefi, R.

    2009-01-01

    We consider a brane world scenario in which the bulk action is assumed to have the form of a generic function of the Ricci scalar f(R) and derive the resulting Einstein field equation on the brane. In a constant curvature bulk a conserved geometric quantity appears in the field equations which can be associated with matter. We present spherically symmetric solutions which account for galaxy rotation curves in a specific form. Then cosmological solutions by assuming a specific form for f(R) are derived which can explain an accelerated expanding universe.

  2. Generation of structural MR images from amyloid PET: Application to MR-less quantification.

    Science.gov (United States)

    Choi, Hongyoon; Lee, Dong Soo

    2017-12-07

    Structural magnetic resonance (MR) images concomitantly acquired with PET images can provide crucial anatomical information for precise quantitative analysis. However, in the clinical setting, not all the subjects have corresponding MR. Here, we developed a model to generate structural MR images from amyloid PET using deep generative networks. We applied our model to quantification of cortical amyloid load without structural MR. Methods: We used florbetapir PET and structural MR data of Alzheimer's Disease Neuroimaging Initiative database. The generative network was trained to generate realistic structural MR images from florbetapir PET images. After the training, the model was applied to the quantification of cortical amyloid load. PET images were spatially normalized to the template space using the generated MR and then standardized uptake value ratio (SUVR) of the target regions was measured by predefined regions-of-interests. A real MR-based quantification was used as the gold standard to measure the accuracy of our approach. Other MR-less methods, a normal PET template-based, multi-atlas PET template-based and PET segmentation-based normalization/quantification methods, were also tested. We compared performance of quantification methods using generated MR with that of MR-based and MR-less quantification methods. Results: Generated MR images from florbetapir PET showed visually similar signal patterns to the real MR. The structural similarity index between real and generated MR was 0.91 ± 0.04. Mean absolute error of SUVR of cortical composite regions estimated by the generated MR-based method was 0.04±0.03, which was significantly smaller than other MR-less methods (0.29±0.12 for the normal PET-template, 0.12±0.07 for multiatlas PET-template and 0.08±0.06 for PET segmentation-based methods). Bland-Altman plots revealed that the generated MR-based SUVR quantification was the closest to the SUVR values estimated by the real MR-based method. Conclusion

  3. Study of some chaotic inflationary models in f(R) gravity

    Science.gov (United States)

    Sharif, M.; Nawazish, Iqra

    2018-04-01

    In this paper, we discuss an inflationary scenario via scalar field and fluid cosmology for an anisotropic homogeneous universe model in f(R) gravity. We consider an equation of state which corresponds to a quasi-de Sitter expansion and investigate the effect of the anisotropy parameter for different values of the deviation parameter. We evaluate potential models like linear, quadratic and quartic models which correspond to chaotic inflation. We construct the observational parameters for a power-law model of f(R) gravity and construct the graphical analysis of tensor-scalar ratio and spectral index which indicates the consistency of these parameters with Planck 2015 data.

  4. Brain PET and functional MRI: why simultaneously using hybrid PET/MR systems?

    Science.gov (United States)

    Cecchin, Diego; Palombit, Alessandro; Castellaro, Marco; Silvestri, Erica; Bui, Franco; Barthel, Henryk; Sabri, Osama; Corbetta, Maurizio; Bertoldo, Alessandra

    2017-12-01

    between these two modalities. However, at least in one study the correlation at the level of gray, white matter, and whole brain is rather good (r=0.94, 0.8, 0.81 respectively). Finally, receptor studies show that simultaneous PET/fMRI could be a useful tool to characterize functional connectivity along with dynamic neuroreceptor adaptation in several physiological (e.g. working memory) or pathological (e.g. pain) conditions, with or without drug administrations. The simultaneous acquisition of PET (using a number of radiotracers) and functional MRI (using a number of sequences) offers exciting opportunities that we are just beginning to explore. The results thus far are promising in the evaluation of cerebral metabolism/flow, neuroreceptor adaptation, and network's energetic demand.

  5. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  6. Revisiting van der Waals like behavior of f(R AdS black holes via the two point correlation function

    Directory of Open Access Journals (Sweden)

    Jie-Xiong Mo

    2017-05-01

    Full Text Available Van der Waals like behavior of f(R AdS black holes is revisited via two point correlation function, which is dual to the geodesic length in the bulk. The equation of motion constrained by the boundary condition is solved numerically and both the effect of boundary region size and f(R gravity are probed. Moreover, an analogous specific heat related to δL is introduced. It is shown that the T−δL graphs of f(R AdS black holes exhibit reverse van der Waals like behavior just as the T−S graphs do. Free energy analysis is carried out to determine the first order phase transition temperature T⁎ and the unstable branch in T−δL curve is removed by a bar T=T⁎. It is shown that the first order phase transition temperature is the same at least to the order of 1010 for different choices of the parameter b although the values of free energy vary with b. Our result further supports the former finding that charged f(R AdS black holes behave much like RN-AdS black holes. We also check the analogous equal area law numerically and find that the relative errors for both the cases θ0=0.1 and θ0=0.2 are small enough. The fitting functions between log⁡|T−Tc| and log⁡|δL−δLc| for both cases are also obtained. It is shown that the slope is around 3, implying that the critical exponent is about 2/3. This result is in accordance with those in former literatures of specific heat related to the thermal entropy or entanglement entropy.

  7. Pulmonary branch arterial flow can be measured with cine MR velocity mapping

    International Nuclear Information System (INIS)

    Caputo, G.R.; Kondo, C.; Masui, T.; Foster, E.; Geraci, S.J.; O'Sullivan, M.; Higgins, C.B.

    1990-01-01

    This paper assesses the capability of cine MR phase velocity mapping (CVM) to measure main, right-sided, and left-sided pulmonary arterial (PA) blood flow. The authors examined a constant-flow phantom and nine healthy volunteers with use of 1.5-T MR imaging system (GE Signa) with phase velocity cine sequences. CVM correctly measured constant-flow phantom velocities (range, 20-190 cm/sec; r = .998, SEE = 4.2 cm/sec), and velocity with use of angulated planes to section the phantom tube perpendicularly. CVM peak systolic main PA velocity (79 cm/sec ± 10) correlated well with Doppler US measurements (80 cm/sec ± 7). CVM main PA flow correlated well with conventional cine MR LV stroke volume measurements (r = .98, SEE = 4.8 mL). Left and right PA flow on the angulated planes were 29 mL ± 7 and 34 mL ± 10, respectively

  8. Evaluating item endorsement rates for the MMPI-2-RF F-r and Fp-r scales across ethnic, gender, and diagnostic groups with a forensic inpatient sample.

    Science.gov (United States)

    Glassmire, David M; Jhawar, Amandeep; Burchett, Danielle; Tarescavage, Anthony M

    2017-05-01

    The Minnesota Multiphasic Personality Inventory-2 (MMPI-2) F(p) (Infrequency-Psychopathology) scale was developed to measure overreporting in a manner that was minimally confounded by genuine psychopathology, which was a problem with using the MMPI-2 F (Infrequency) scale among patients with severe mental illness. Although revised versions of both of these scales are included on the MMPI-2-Restructured Form and used in a forensic context, no item-level research has been conducted on their sensitivity to genuine psychopathology among forensic psychiatric inpatients. Therefore, we examined the psychometric properties of the scales in a sample of 438 criminally committed forensic psychiatric inpatients who were adjudicated as not guilty by reason of insanity and had no known incentive to overreport. We found that 20 of the 21 Fp-r items (95.2%) demonstrated endorsement rates ≤ 20%, with 14 of the items (66.7%) endorsed by less than 10% of the sample. Similar findings were observed across genders and across patients with mood and psychotic disorders. The one item endorsed by more than 20% of the sample had a 23.7% overall endorsement rate and significantly different endorsement rates across ethnic groups, with the highest endorsements occurring among Hispanic/Latino (43.3% endorsement rate) patients. Endorsement rates of F-r items were generally higher than for Fp-r items. At the scale level, we also examined correlations with the Restructured Clinical Scales and found that Fp-r demonstrated lower correlations than F-r, indicating that Fp-r is less associated with a broad range of psychopathology. Finally, we found that Fp-r demonstrated slightly higher specificity values than F-r at all T score cutoffs. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  9. Acute interstitial edematous pancreatitis: Findings on non-enhanced MR imaging

    Science.gov (United States)

    Zhang, Xiao-Ming; Feng, Zhi-Song; Zhao, Qiong-Hui; Xiao, Chun-Ming; Mitchell, Donald G; Shu, Jian; Zeng, Nan-Lin; Xu, Xiao-Xue; Lei, Jun-Yang; Tian, Xiao-Bing

    2006-01-01

    AIM: To study the appearances of acute interstitial edematous pancreatitis (IEP) on non-enhanced MR imaging. METHODS: A total of 53 patients with IEP diagnosed by clinical features and laboratory findings were underwent MR imaging. MR imaging sequences included fast spoiled gradient echo (FSPGR) fat saturation axial T1-weighted imaging, gradient echo T1-weighted (in phase), single shot fast spin echo (SSFSE) T2-weighted, respiratory triggered (R-T) T2-weighted with fat saturation, and MR cholangiopancreatography. Using the MR severity score index, pancreatitis was graded as mild (0-2 points), moderate (3-6 points) and severe (7-10 points). RESULTS: Among the 53 patients, IEP was graded as mild in 37 patients and as moderate in 16 patients. Forty-seven of 53 (89%) patients had at least one abnormality on MR images. Pancreas was hypointense relative to liver on FSPGR T1-weighted images in 18.9% of patients, and hyperintense in 25% and 30% on SSFSE T2-weighted and R-T T2-weighted images, respectively. The prevalences of the findings of IEP on R-T T2-weighted images were, respectively, 85% for pancreatic fascial plane, 77% for left renal fascial plane, 55% for peripancreatic fat stranding, 42% for right renal fascial plane, 45% for perivascular fluid, 40% for thickened pancreatic lobular septum and 25% for peripancreatic fluid, which were markedly higher than those on in-phase or SSFSE T2-weighted images (P fluid. R-T T2-weighted imaging is more sensitive than in-phase and SSFSE T2-weighted imaging for depicting IEP. PMID:17007053

  10. Importprocessen för inrednings- och gåvoartiklar från USA till Finland : En handbok för företagaren

    OpenAIRE

    Smeds, Desiré; Backlund, Johanna

    2016-01-01

    Det här examensarbetet handlar om import från USA med fokus på inrednings- och gåvoartiklar. I arbetet lyfter vi steg för steg fram de delar som utgör importprocessen hela vägen från hur man hittar en pålitlig leverantör till förtullningen av produkterna här i Finland. Syftet med arbetet är att det skall kunna fungera som en handbok för företag som vill starta en småskalig importverksamhet av inrednings- och gåvoartiklar. Vi tar även upp information om import och internationell handel i a...

  11. Wormholes in viable f(R) modified theories of gravity and weak energy condition

    Energy Technology Data Exchange (ETDEWEB)

    Pavlovic, Petar [Universitaet Hamburg, II. Institut fuer Theoretische Physik, Hamburg (Germany); Sossich, Marko [University of Zagreb, Department of Physics, Faculty of Electrical Engineering and Computing, Zagreb (Croatia)

    2015-03-01

    In this work wormholes in viable f(R) gravity models are analyzed. We are interested in exact solutions for stress-energy tensor components depending on different shape and redshift functions. Several solutions of gravitational equations for different f(R) models are examined. The solutions found imply no need for exotic material, while this need is implied in the standard general theory of relativity. A simple expression for weak energy condition (WEC) violation near the throat is derived and analyzed. High curvature regime is also discussed, as well as the question of the highest possible values of the Ricci scalar for which the WEC is not violated near the throat, and corresponding functions are calculated for several models. The approach here differs from the one that has been common since no additional assumptions to simplify the equations have been made, and the functions in f(R) models are not considered to be arbitrary functions, but rather a feature of the theory that has to be evaluated on the basis of consistency with observations for the Solar System and cosmological evolution. Therefore in this work we show that the existence of wormholes without exotic matter is not only possible in simple arbitrary f(R) models, but also in models that are in accordance with empirical data. (orig.)

  12. MR imaging in chronic epicondylitis humeri radialis at 1.0 T: is Gd-DTPA administration useful?

    International Nuclear Information System (INIS)

    Herber, S.; Kalden, P.; Kreitner, K.-F.; Thelen, M.

    2001-01-01

    Purpose: Evaluation of the diagnostic value and confidence of contrast-enhanced MR imaging in patients with lateral epicondylitis in comparison to clinical diagnosis. Material and Methods: 42 consecutive patients with clinically proven chronic lateral epicondylitis and 10 elbow joints of healthy controls have been examined on a 1.0 T MR-unit. Criteria for inclusion in the prospective study were: persistant pain and a failed conservative therapy. The MR protocol included STIR sequence, a native, T 2 -weighted, fat-supressed TSE sequence, and a flash-2-D sequence. Also, fat-supressed, T 1 -weighted SE sequences before and after administration of Gd-DTPA contrast media have been recorded. Results: In 39/42 patients the STIR sequence showed an increased SI of the common extensor tendom. Increased MR signal of the lateral collateral ligament combined with a thickening and a partial rupture or a full thickness tear have been observed in 15/42 cases. A bone marrow edema at the lateral epicondylus was noticed in 6 of the studied patients and a joint effusion in 18/42 patients. After administration of contrast media we noticed an average increase of SI by about 150%. However, enhanced MR imaging did not provide additional information. Conclusion: In MR imaging of chronic epicondylitis administration of gadolinium-DTPA does not provide additional information. (orig.) [de

  13. 78 FR 802 - Heart of Texas Railroad, L.P.-Acquisition and Operation Exemption-Gulf Colorado & San Saba...

    Science.gov (United States)

    2013-01-04

    ... Railroad, L.P.--Acquisition and Operation Exemption--Gulf Colorado & San Saba Railway Company Heart of Texas Railroad, L.P. (the Company), a noncarrier, has filed a verified notice of exemption under 49 CFR..., 2013. Rachel D. Campbell, Director, Office of Proceedings. Jeffrey Herzig, Clearance Clerk. [FR Doc...

  14. M&R Holdings, LLC d/b/a Brandon’s Reserve Residential Development - Clean Water Act Public Notice

    Science.gov (United States)

    The EPA is providing notice of an Administrative Penalty Assessment in the form of an Expedited Storm Water Settlement Agreement against M&R Holdings, LLC d/b/a Brandon’s Reserve Residential Development, a business located at 15602 Wilden Drive, Urbandale,

  15. MR of experimental cerebral ischemia

    International Nuclear Information System (INIS)

    DeLaPaz, R.; Steinberg, G.; Rocklage, S.; Glover, G.H.

    1990-01-01

    This paper reports on MR imaging of cerebral ischemia and treatment with N-methyl-D-aspartate (NMDA) antagonists in an animal model. Forty-four New Zealand white rabbits underwent 1-hour transorbital ICA-MCA-ACA occlusion and pretreatment or immediate posttreatment with systemic dextromethorphan (DM, n = 14), dextrorphan (DX, n = 14), or normal saline (NS, n = 16). Serial MR studies (1.5 T) were performed 1--6 hours after occlusion with T1- and T2-weighted spinecho, IVIM (b = 1,352), gradient recalled acquisition in a steady-state, and chemical shift sequences (for magnetic susceptibility, T2* and T2') and DyDTPA-BMA intravenous contrast material (Salutar). Spatial correlation between MR findings, histologic findings (ischemic neuronal damage), and regional cerebral blood flow (microspheres) was done

  16. Quantification of hepatic steatosis with T1-independent, T2-corrected MR imaging with spectral modeling of fat: blinded comparison with MR spectroscopy.

    Science.gov (United States)

    Meisamy, Sina; Hines, Catherine D G; Hamilton, Gavin; Sirlin, Claude B; McKenzie, Charles A; Yu, Huanzhou; Brittain, Jean H; Reeder, Scott B

    2011-03-01

    To prospectively compare an investigational version of a complex-based chemical shift-based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24-71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r(2)), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2 correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2 correction, spectral modeling of fat, and magnitude fitting for eddy current correction were used (r(2

  17. Correlation of proton MR spectroscopy of primary intracranial tumours and histopathological findings: preliminarily findings

    International Nuclear Information System (INIS)

    Mandel, C.; Birchall, D.; Ellison, D.; Crawford, P.J.

    2002-01-01

    Full text: Proton MR spectroscopy is becoming more widely available in the clinical setting, and is increasingly used for the analysis of focal intracranial mass lesions. Several papers have indicated that MR spectroscopy can be applied not only to the differentiation of tumour from non-neoplastic pathologies, but that it may also have a role in the grading of differing histological grades of tumour. MR spectroscopy has therefore been proposed as a means of non-invasive biopsy, but its validation in this context is a necessary prerequisite for its use in this manner. Currently at our centre, all patients undergoing surgical biopsy for intracranial tumour are being imaged preoperatively with proton MR spectroscopy, and comparison made with the histopathological findings. To date, 20 patients (12 male, 8 female, age range 24-72) with primary intracranial tumour have been included in the study. Patients were imaged with conventional MR scanning and proton MR spectroscopy on a Philips Intera 1.5T scanner. Chemical shift spectroscopy was performed in each case (TR 2000 msec, TE 272 msec, slice thickness 20mm, acquisition time 15:53) in an axial plane at the level of tumour. Voxels were chosen within the lesion and within remote normal appearing white matter, and the corresponding spectra were interrogated. The heights of the peaks corresponding to choline (Cho), creatine (Cr), N-acetyl aspartate (NAA) and lactate / lipid (Lip) were measured using a semi-quantitative scale. Cho:NAA, Cho:Cr, Cho: Chonormal, Cho:Crnormal, Lip:Crnormal, Chonormal:NAAnormal and Chonormal:Crnormal ratios were calculated. Biopsy was performed by the neurosurgical team, and histopathological analysis performed by a single consultant neuropathologist. Histological analysis demonstrated 10 glioblastomas, 4 anaplastic astrocytomas and 6 low grade gliomas. Spectral analysis demonstrated a mean Cho:NAA and Cho:Cr of 0.3 and 0.8 respectively for normal white matter. Cho:NAA and Cho:Cr were

  18. Dysembryoplastic neuroepithelial tumors: proton MR spectroscopy, diffusion and perfusion characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Bulakbasi, Nail; Kocaoglu, Murat; Sanal, Tuba H.; Tayfun, Cem [Gulhane Military Medical Academy, Department of Radiology, Military Medical Faculty, Ankara (Turkey)

    2007-10-15

    We describe the magnetic resonance (MR) imaging characteristics of dysembryoplastic neuroepithelial tumors (DNT) and discuss their differential diagnosis. Proton MR spectroscopy (TE 30 and 136 ms), diffusion-weighted and perfusion images were retrospectively evaluated in 22 patients with pathologically proven DNT (17 male and 5 female, mean age 18.7 years) and 14 control subjects (10 male and 4 female, mean age 16.9 years). The results from the DNT patients and from the control subjects were compared using an independent sample t-test and the degree of correlation was tested by Pearson's correlation. All DNTs were solitary and in a supratentorial cortical or subcortical location (ten temporal, eight frontal and four parietal). They had low-signal on T1-weighted images and high-signal on T2-weighted images without a prominent mass effect. Additionally a cystic appearance (six patients, 27.3%), cortical dysplasia (six patients, 27.3%) and contrast enhancement (four patients, 18.2%) were also noted. No significant differences were detected in NAA/Cho, NAA/Cr, NAA/Cho+Cr or Cho/Cr ratios between DNT and normal brain. DNTs had a significantly higher mI/Cr ratio and apparent diffusion coefficient (ADC) values and lower cerebral blood values than normal parenchyma (P < 0.001). ADC had the highest correlation with the diagnosis of DNT (r = 0.996) followed by relative cerebral blood volume (rCBV) (r = -0.883) and mI/Cr ratio (r = 0.663). Proton MR spectroscopy, diffusion-weighted and perfusion imaging characteristics of DNTs provide additional information to their MR imaging findings. The MR spectrum showing a slight increase in mI/Cr ratio, and higher ADC and lower rCBV values than normal parenchyma help to differentiate DNTs from other cortical tumors, which had higher rCBV and lower ADC values than DNTs. (orig.)

  19. 75 FR 81915 - Defense Federal Acquisition Regulation Supplement; Foreign Participation in Acquisitions in...

    Science.gov (United States)

    2010-12-29

    ... prescriptions. Amends 225.1101(6)(i) to reference the World Trade Organization (WTO) Government Procurement... Subjects in 48 CFR Parts 225 and 252 Government procurement. Ynette R. Shelkin, Editor, Defense Acquisition... paragraph (c)(iii) to read as follows: 225.403 World Trade Organization Government Procurement Agreement and...

  20. Unigene BLAST: CBRC-DMEL-08-0038 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-DMEL-08-0038 gnl|UG|Dm#S40593121 DMG1C.2_1.G07.C1 MODENCODE_DM_A Drosophila melanogaster cDNA clone DMG...1-chr3R.3.082.a, mRNA sequence /clone=DMG1-chr3R.3.082.a /gb=EW713160 /gi=156142114 /ug=Dm.27906 /len=1533 6e-10 32% ...

  1. ANALYSIS OF SPATIAL PATTERN AND INFLUENCING FACTORS OF E-COMMERCE

    OpenAIRE

    Y. Zhang; J. Chen; S. Zhang

    2017-01-01

    This paper aims to study the relationship between e-commerce development and geographical characteristics using data of e-commerce, economy, Internet, express delivery and population from 2011 to 2015. Moran’s I model and GWR model are applied to analyze the spatial pattern of E-commerce and its influencing factors. There is a growth trend of e-commerce from west to east, and it is obvious to see that e-commerce development has a space-time clustering, especially around the Yangtze R...

  2. Cine MR imaging of internal derangements of the knee

    International Nuclear Information System (INIS)

    Niitsu, M.; Anno, I.; Ishikawa, N.; Akisada, M.; Fukubayashi, T.

    1990-01-01

    This paper assesses internal derangements of the knee joint by a new method of cine MR imaging. Cine MR imaging, involving cine acquisition of kinematic sagittal images during knee movement, was used to evaluate 51 symptomatic patients and 19 healthy subjects. Cine MR images of cruciate ligament fears showed disappearance of low-intensity bundles during knee movement, periodic appearance of joint fluid in the area of the ligament, and irregular tibial movement. Cine MR images of meniscal tears showed independent movement of meniscal fragments and periodic tear opening and closing. Twenty-seven of the 28 anterior cruciate ligament (ACL) tears confirmed arthroscopically were correctly identified with cine MR imaging, with a sensitivity of 96% and a specificity of 92%

  3. Fast MR imaging and ultrafast MR imaging of fetal central nervous system abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Shakudo, Miyuki; Manabe, Takao; Murata, Katsuko; Matsuo, Ryoichi; Oda, Junro [Osaka City General Hospital (Japan); Inoue, Yuichi; Mochizuki, Kunizo; Yamada, Ryusaku

    2001-12-01

    The aims of this study were two: to compare the efficacy of fast MRI (breath-hold fast spin-echo T2-weighted and fast gradient-echo T1-weighted sequence) and ultrafast MRI (half-Fourier acquisition single-shot turbo spin-echo sequence) in evaluation of fetal central nervous system (CNS) abnormalities at late gestational age, and to compare the capability of fast MRI and ultrafast MRI to assess fetal CNS abnormalities with that of prenatal ultrasonography (US). Forty-nine women with fetuses at gestational ages of 26-39 weeks underwent fast MRI (29 patients) or ultrafast MRI (20 patients). In detection of motion artifact, visualization of the lateral and 4th ventricles, and differentiation between gray and white matter in cerebral hemispheres, ultrafast MRI was significantly superior to fast MRI (p<0.0001, Mann-Whitney U test). In 25 of 43 cases, US and MR diagnoses were the same and consistent with postnatal diagnosis. In 10 of 43 cases, MRI demonstrated findings additional to or different from those of US, and MR findings were confirmed postnatally. MRI, particularly ultrafast MRI, is useful for demonstrating CNS abnormalities in situations in which US is suggestive but not definitive. (author)

  4. MR angiography, MR imaging and proton MR spectroscopy in-vivo assessment of skeletal muscle ischemia in diabetic rats.

    Directory of Open Access Journals (Sweden)

    Stefano Delli Pizzi

    Full Text Available To prospectively evaluate the feasibility of using magnetic resonance (MR techniques for in-vivo assessing a rat diabetic model of limb ischemia. Unilateral hind limb ischemia was induced by ligation of the iliac-femoral artery in male streptozotocin-treated and non-diabetic control rats. Four weeks after ligation, rats underwent MR Angiography (MRA, T(1-weighted and Short Time Inversion Recovery (STIR sequences and muscle Proton MR Spectroscopy ((1H-MRS on both hind limbs. After MR examinations, immunoblotting and immunofluorescence analysis were performed. MRA showed a signal void due to flow discontinuation distal to the artery ligation. T(1-weighted and STIR images showed, respectively, the presence of tissue swelling (p = 0.018 for non-diabetic; p = 0.027 for diabetic rats and signal hyperintensity in tissue affected by occlusion. Mean total creatine/water for the occluded limb was significantly lower than for the non-occluded limbs in both non-diabetic (5.46×10(-4 vs 1.14×10(-3, p = 0.028 and diabetic rats (1.37×10(-4 vs 1.10×10(-3; p = 0.018. MR Imaging and (1H-MRS changes were more pronounced in diabetic than in non-diabetic occluded limbs (p = 0.032. MR findings were confirmed by using histological findings. Combined MR techniques can be used to demonstrate the presence of structural and metabolic changes produced by iliac-femoral artery occlusion in rat diabetic model of limb ischemia.

  5. Framework for the construction of a Monte Carlo simulated brain PET–MR image database

    International Nuclear Information System (INIS)

    Thomas, B.A.; Erlandsson, K.; Drobnjak, I.; Pedemonte, S.; Vunckx, K.; Bousse, A.; Reilhac-Laborde, A.; Ourselin, S.; Hutton, B.F.

    2014-01-01

    Simultaneous PET–MR acquisition reduces the possibility of registration mismatch between the two modalities. This facilitates the application of techniques, either during reconstruction or post-reconstruction, that aim to improve the PET resolution by utilising structural information provided by MR. However, in order to validate such methods for brain PET–MR studies it is desirable to evaluate the performance using data where the ground truth is known. In this work, we present a framework for the production of datasets where simulations of both the PET and MR, based on real data, are generated such that reconstruction and post-reconstruction approaches can be fairly compared. -- Highlights: • A framework for simulating realistic brain PET–MR images is proposed. • The imaging data created is formed from real acquisitions. • Partial volume correction techniques can be fairly compared using this framework

  6. Framework for the construction of a Monte Carlo simulated brain PET–MR image database

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, B.A., E-mail: benjamin.thomas2@uclh.nhs.uk [Institute of Nuclear Medicine, UCL, London (United Kingdom); Erlandsson, K. [Institute of Nuclear Medicine, UCL, London (United Kingdom); Drobnjak, I.; Pedemonte, S. [Centre for Medical Image Computing, UCL, London (United Kingdom); Vunckx, K. [Department of Nuclear Medicine, Katholieke Universiteit Leuven, Leuven (Belgium); Bousse, A. [Institute of Nuclear Medicine, UCL, London (United Kingdom); Reilhac-Laborde, A. [Australian Nuclear Science and Technology Organization, Sydney (Australia); Ourselin, S. [Centre for Medical Image Computing, UCL, London (United Kingdom); Hutton, B.F. [Institute of Nuclear Medicine, UCL, London (United Kingdom); Centre for Medical Radiation Physics, University of Wollongong, NSW (Australia)

    2014-01-11

    Simultaneous PET–MR acquisition reduces the possibility of registration mismatch between the two modalities. This facilitates the application of techniques, either during reconstruction or post-reconstruction, that aim to improve the PET resolution by utilising structural information provided by MR. However, in order to validate such methods for brain PET–MR studies it is desirable to evaluate the performance using data where the ground truth is known. In this work, we present a framework for the production of datasets where simulations of both the PET and MR, based on real data, are generated such that reconstruction and post-reconstruction approaches can be fairly compared. -- Highlights: • A framework for simulating realistic brain PET–MR images is proposed. • The imaging data created is formed from real acquisitions. • Partial volume correction techniques can be fairly compared using this framework.

  7. Evaluation of thermometric monitoring for intradiscal laser ablation in an open 1.0 T MR scanner.

    Science.gov (United States)

    Wonneberger, Uta; Schnackenburg, Bernhard; Wlodarczyk, Waldemar; Rump, Jens; Walter, Thula; Streitparth, Florian; Teichgräber, Ulf Karl Mart

    2010-01-01

    The purpose of this study was to evaluate different methods of magnetic resonance thermometry (MRTh) for the monitoring of intradiscal laser ablation therapy in an open 1.0 Tesla magnetic resonance (MR) scanner. MRTh methods based on the two endogenous MR temperature indicators of spin-lattice relaxation time T1 and water proton resonance frequency (PRF) shift were optimised and compared in vitro. For the latter, we measured the effective spin-spin relaxation times T2* in intervertebral discs of volunteers. Then we compared four gradient echo-based imaging techniques to monitor laser ablations in human disc specimens. Criteria of assessment were outline of anatomic detail, immunity against needle artefacts, signal-to-noise ratio (SNR) and accuracy of the calculated temperature. T2* decreased in an inverse and almost linear manner with the patients' age (r = 0.9) from 70 to 30 ms (mean of 49 ms). The optimum image quality (anatomic details, needle artefacts, SNR) and temperature accuracy (+/-1.09 degrees C for T1-based and +/-1.11 degrees C for PRF-based MRTh) was achieved with a non-spoiled gradient-echo sequence with an echo time of TE = 10 ms. Combination of anatomic and thermometric non-invasive monitoring of laser ablations in the lumbar spine is feasible. The temperature accuracy of the investigated T1- and PRF-based MRTh methods in vitro is high enough and promises to be reliable in vivo as well.

  8. Diffusion-weighed MR of the thyroid gland in Graves' disease: assessment of disease activity and prediction of outcome.

    Science.gov (United States)

    Abdel Razek, Ahmed Abdel Khalek; Sadek, Ahmed Galal; Gaballa, Gada

    2010-06-01

    To assess the activity and clinical course of Graves' disease with diffusion-weighted magnetic resonance (MR) imaging. Fifty-one patients with Graves' disease and 25 volunteers underwent diffusion MR imaging of the thyroid gland using a single shot echo-planar imaging with b-factor of 0, 300 and 600 second/mm(2). The apparent diffusion coefficient (ADC) values of the thyroid gland were calculated. Patients with active Graves' disease included untreated patients at initial diagnosis (n = 12), patients under antithyroid drugs (n = 11), and patients in relapse after withdrawal of therapy (n = 13). Patients with inactive disease had a remission of hyperthyroidism (n = 15). The mean ADC values of thyroid gland with active Graves' disease was 0.65 +/- 0.03 x 10(-3) mm(2)/second in patients at initial diagnosis, 0.81 +/- 0.02 x 10(-3) mm(2)/second in patients undergoing antithyroid drug and 0.72 +/- 0.07 x 10(-3) mm(2)/second in patients with relapse of hyperthyroidism. The mean ADC of patients with remission was 0.94 +/- 0.03 x 10(-3) mm(2)/second and for normal volunteer was 1.06 +/- 0.08 x 10(-3) mm(2)/second. There was significant difference in the ADC value of patients with active disease and remission (P = .001). The cutoff ADC value used for differentiating patients with active disease from patients with remission was 0.82 x 10(-3) mm(2)/second. The mean ADC value of thyroid gland had positive correlation with thyroid-stimulating hormone (r = 0.87, P = .001) and negative correlation with serum T4 (r = -0.82, P = .001) and serum T3 (r = -0.71, P = .001). The ADC value of the thyroid gland is a promising non invasive parameter for diagnosis of different clinical stages of Graves' disease. Hence it can be used to assess the activity and predict the outcome of patients during and after medical treatment. Crown Copyright (c) 2010. Published by Elsevier Inc. All rights reserved.

  9. 78 FR 67177 - Center for Scientific Review; Amended Notice of Meeting

    Science.gov (United States)

    2013-11-08

    ... Technology A Study Section, October 07, 2013, 08:00 a.m. to October 08, 2013, 05:00 p.m., Hilton Alexandria... September 10, 2013, 78 FR 175 Pgs. 55268-55270. The meeting will be held at the Hilton Rockville, 1750...

  10. Partial pressure (or fugacity) of carbon dioxide, salinity and SEA SURFACE TEMPERATURE collected from time series observations using Carbon dioxide (CO2) gas analyzer, Shower head chamber equilibrator for autonomous carbon dioxide (CO2) measurement and other instruments from Polaris II in the South Pacific Ocean from 2006-08-29 to 2006-10-24 (NODC Accession 0112883)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NCEI Accession 0112883 includes time series data collected from Polaris II in the South Pacific Ocean from 2006-08-29 to 2006-10-24. These data include Partial...

  11. Significance of MR imaging in patients with pulmonary hypertension

    International Nuclear Information System (INIS)

    Frank, H.; Globits, S.; Mayr, H.; Lang, I.; Kneussl, M.; Glogar, D.; Miczoch, J.; Neuhold, A.; Imhof, H.

    1989-01-01

    To determine the diagnostic impact of MR imaging in pulmonary hypertension (PH), the authors have examined 12 PH patients with a 0.5- or 1.5-T magnet in a double-angulation projection with multisection, multiphase technique and a gradient-echo sequence. MR data were evaluated for right ventricular volumes or function and compared with data from 10 control subjects. In PH patients, MR imaging showed right ventricular enlargement with hypertrophy, right atrial enlargement, and abnormal septal motion. Right ventricular (RV) function was compromised, with reduced RV circumferential shortening. PH patients had a severe reduction of long-axis shortening and variable reduction of short-axis shortening that correlated with the degree of PH (r = .68, P <.01)

  12. Evaluation of PET performance and MR compatibility of a preclinical PET/MR insert with digital silicon photomultiplier technology

    Energy Technology Data Exchange (ETDEWEB)

    Hallen, Patrick; Schug, David; Wehner, Jakob [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Weissler, Bjorn [Department of Chemical Application Research, Philips Research (Germany); Gebhardt, Pierre [Division of Imaging Sciences and Biomedical Engineering, King’s College London (United Kingdom); Goldschmidt, Benjamin [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Salomon, Andre [Department of Oncology Solutions, Philips Research (Germany); Duppenbecker, Peter [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany); Kiessling, Fabian [Institute for Experimental Molecular Imaging, RWTH Aachen University (Germany); Schultz, Volkmar [Department of Physics of Molecular Imaging Systems, RWTH Aachen University (Germany)

    2015-05-18

    In this work we present detailed characterizations of our preclinical high resolution PET/MR insert based on the Hyperion-IID platform. The PET/MR insert consists of a ring of 10 singles detection modules, each comprising 2x3 scintillation detector stacks. Each detector stack features a 30x30 pixelated LYSO crystal array with a height of 12 mm and a pitch of 1 mm, coupled via a slit 2 mm light guide to a digital SiPM tile. The PET performance is stable under a wide range of operating points. The spatial resolution is below 1Ä,mm and the CRT reaches 260 or 450 ps depending on trigger settings. The energy resolution is 12.6% FWHM. The characterization of the MR compatibility showed no relevant degradation in PET performance during MRI operation. On the MRI side, we observe a degradation in B0 homogeneity from a VRMS of 0.03 ppm to 0.08 ppm with active shimming, while observing only minor degradations in the B0 field. The noise floor is slightly increased by 2-15% without any observable dependence on the activity. The Z gradients induces an observable eddy current inside the PET inserts which can lead to ghosting artifacts for EPI sequences. However, we don't observe any visible image degradation for widely used anatomical imaging sequences such as gradient echo and turbo spin echo sequences. To prove the viability of our PET/MR insert for in vivo small animal studies, we successfully performed a longitudinal mouse study with subcutaneously injected tumor model cells. The simultaneously acquired PET/MR images provide a high level of anatomical information and soft tissue contrast in the MR layer together with a high resolution image of the FDG tracer distribution in the PET layer.

  13. Wayne and Washtenaw Counties 1.0 PPSM LiDAR

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — TASK NAME: Wayne and Washtenaw Counties 1.0 PPSM LiDAR LiDAR Data Acquisition and Processing Production Task USGS CONTRACT: 07CRCN0006 TASK ORDER NUMBER: G09PD00300...

  14. Value of new MR techniques in MR-PET; Stellenwert neuer MR-Techniken in der MR-PET

    Energy Technology Data Exchange (ETDEWEB)

    Attenberger, U.I.; Schoenberg, S.O. [Universitaetsmedizin Mannheim, Medizinische Fakultaet Mannheim der Universitaet Heidelberg, Institut fuer klinische Radiologie und Nuklearmedizin, Mannheim (Germany); Quick, H.H. [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Institut fuer Medizinische Physik, Erlangen (Germany); Guimaraes, A. [Massachusetts General Hospital, Martinos Center for Biomedical Imaging, Department of Radiology, Charlestown (United States); Catalano, O. [University of Naples Federico II, Naples (Italy); Morelli, J.N. [The Johns Hopkins Hospital, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore (United States)

    2013-12-15

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [German] Die klinische Implementierung der neuen Hybridtechnologie MR-Positronenemissionstomographie (MR-PET) bietet durch die Kombination aus hochaufloesender Morphologie, Funktion und Metabolismus bisher ungeahnte diagnostische Moeglichkeiten, die nicht nur fuer die Diagnose und die Verlaufskontrolle onkologischer und psychiatrischer Erkrankungen von hoher Bedeutung sind. Verglichen mit der PET-CT wird dies mit reduzierter Strahlenbelastung fuer den Patienten moeglich, was wiederum insbesondere fuer Patienten in der Tumornachsorge, die

  15. 76 FR 63608 - Export Trade Certificate of Review

    Science.gov (United States)

    2011-10-13

    ... Economic Analysis (``OCEA'') of the International Trade Administration, Department of Commerce, has... Analysis, International Trade Administration, (202) 482-5131 (this is not a toll-free number) or e-mail at... Economic Analysis. [FR Doc. 2011-26502 Filed 10-12-11; 8:45 am] BILLING CODE 3510-DR-P ...

  16. MR-guided pain therapy: principles and clinical applications; MR-gesteuerte Schmerztherapie: Prinzipien und klinische Applikationen

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, J.; Pereira, P.L. [Diagnostische Radiologie, Eberhard-Karls-Universitaet, Tuebingen (Germany)

    2007-09-15

    X-ray fluoroscopy and computed tomography are frequently used to perform percutaneous interventions in pain therapy. The development of MR-compatible therapy needles now allows these interventions to be performed under MR imaging guidance. MR-guided interventions may be performed using most clinical MR scanners; however, systems with an open configuration are advantageous. Multiplanar pre- and intra-procedural MR imaging provides the interventionalist with essential information, such as evaluation of anatomy and pathology, as well as the planning of the procedure and monitoring of fluid distribution without the use of contrast agents. With the use of non-ionizing radiation, interventional MR imaging is especially suited for the treatment of children and young adults as well as for serial injection therapy. For spinal MR interventions, passive needle visualization is an easily achievable and reliable method. The resulting needle artifact is influenced by several factors such as the alloy of the needle, the strength of the static magnetic field, the sequence type, the spatial orientation of the therapy needle as well as the echo time and may further be optimized during the intervention by alteration of the last three factors. Fast acquisition techniques and image processing allow for continuous, near real-time MR imaging (so-called MR fluoroscopy) and interactive needle navigations, comparable to X-ray fluoroscopy and CT fluoroscopy. The purpose of this review is to illustrate and discuss general concepts of interventional MR imaging. A spectrum of interventional MR imaging procedures in spinal pain therapy is described and illustrated, including procedures such as lumbar facet joint injections, sacroiliac joint injections, lumbar spinal nerve root infiltrations and drug delivery to the lumbar sympathetic chain. (orig.)

  17. Chemical, physical, profile and other oceanographic data collected aboard NOAA Ship GORDON GUNTER in the Gulf of Mexico from 2010-08-02 to 2010-08-08 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0070333)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile, laboratory analysis and underway oceanographic data were collected aboard NOAA Ship GORDON GUNTER in the Gulf of Mexico from 2010-08-02...

  18. 78 FR 33019 - Proposed Amendment of Class E Airspace; Commerce, TX

    Science.gov (United States)

    2013-06-03

    ...-0269; Airspace Docket No. 13-ASW-3] Proposed Amendment of Class E Airspace; Commerce, TX AGENCY... action proposes to amend Class E airspace at Commerce, TX. Additional controlled airspace is necessary to accommodate new Standard Instrument Approach Procedures (SIAPs) at Commerce Municipal Airport (AAF). The FAA...

  19. Metabolic changes in the auditory cortex in presbycusis demonstrated by MR spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Profant, Oliver; Balogová, Zuzana; Dezortová, M.; Wagnerová, D.; Hájek, M.; Syka, Josef

    2013-01-01

    Roč. 48, č. 8 (2013), s. 795-800 ISSN 0531-5565 R&D Projects: GA ČR GAP304/10/1872 Grant - others:GA MZd(CZ) 00023001IKEM Institutional support: RVO:68378041 Keywords : Presbycusis * Auditory cortex * MR spectroscopy Subject RIV: FH - Neurology Impact factor: 3.529, year: 2013

  20. Detection and staging of chondromalacia patellae: relative efficacies of conventional MR imaging, MR arthrography, and CT arthrography.

    Science.gov (United States)

    Gagliardi, J A; Chung, E M; Chandnani, V P; Kesling, K L; Christensen, K P; Null, R N; Radvany, M G; Hansen, M F

    1994-09-01

    Chondromalacia patellae is a condition characterized by softening, fraying, and ulceration of patellar articular cartilage. We compare the sensitivity, specificity, and accuracy of conventional MR imaging, MR arthrography, and CT arthrography in detecting and staging this abnormality. Twenty-seven patients with pain in the anterior part of the knee were prospectively examined with MR imaging, including T1-weighted (650/16), proton density-weighted (2000/20), T2-weighted (2000/80), and spoiled two-dimensional gradient-recalled acquisition in the steady state (SPGR/)/35 degrees (51/10) with fat saturation pulse sequences. All were also examined with T1-weighted MR imaging after intraarticular injection of dilute gadopentetate dimeglumine and with double-contrast CT arthrography. Each imaging technique was evaluated independently by two observers, who reached a consensus interpretation. The signal characteristics of cartilage on MR images and contour abnormalities noted with all imaging techniques were evaluated and graded according to a modification of the classification of Shahriaree. Twenty-six of the 54 facets examined had chondromalacia shown by arthroscopy, which was used as the standard of reference. The sensitivity, specificity, and accuracy of each imaging technique in the diagnosis of each stage of chondromalacia patellae were determined and compared by using the McNemar two-tailed analysis. Arthroscopy showed that 28 facets were normal. Grade 1 chondromalacia patellae was diagnosed only with MR and CT arthrography in two (29%) of seven facets. Intermediate (grade 2 or 3) chondromalacia patellae was detected in two (13%) of 15 facets with T1-weighted and SPGR MR imaging, in three (20%) of 15 facets with proton density-weighted MR imaging, in seven (47%) of 15 facets with T2-weighted MR imaging, in 11 (73%) of 15 facets with CT arthrography, and in 12 (80%) of 15 facets with MR arthrography. Grade 4 was detected in three (75%) of four facets with T1-, proton

  1. 77 FR 48964 - Certain Pasta From Italy: Notice of Court Decision Not in Harmony With Final Results of...

    Science.gov (United States)

    2012-08-15

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-475-818] Certain Pasta From Italy... pasta from Italy with respect to the margin assigned to Atar S.r.L. (Atar) covering the period of review... Review of the Antidumping Duty Order on Certain Pasta from Italy, 72 FR 7011 (February 14, 2007) (Final...

  2. Pärimuslik ajalugu ja Fr. R. Kreutzwald / Tiiu Jaago

    Index Scriptorium Estoniae

    Jaago, Tiiu, 1960-

    2005-01-01

    Pärimuslik ajalugu kui rahvapärane ajalookäsitus, mida saab uurida folkloorse jutustamise kaudu. Fr. R. Kreutzwaldi ja F. K. H. Kruse sõnavõttudest Aruküla koobaste päritolu kohta ajakirjas "Das Inland" aastast 1844

  3. Quantification of Hepatic Steatosis with T1-independent, T2*-corrected MR Imaging with Spectral Modeling of Fat: Blinded Comparison with MR Spectroscopy

    Science.gov (United States)

    Hines, Catherine D. G.; Hamilton, Gavin; Sirlin, Claude B.; McKenzie, Charles A.; Yu, Huanzhou; Brittain, Jean H.; Reeder, Scott B.

    2011-01-01

    Purpose: To prospectively compare an investigational version of a complex-based chemical shift–based fat fraction magnetic resonance (MR) imaging method with MR spectroscopy for the quantification of hepatic steatosis. Materials and Methods: This study was approved by the institutional review board and was HIPAA compliant. Written informed consent was obtained before all studies. Fifty-five patients (31 women, 24 men; age range, 24–71 years) were prospectively imaged at 1.5 T with quantitative MR imaging and single-voxel MR spectroscopy, each within a single breath hold. The effects of T2* correction, spectral modeling of fat, and magnitude fitting for eddy current correction on fat quantification with MR imaging were investigated by reconstructing fat fraction images from the same source data with different combinations of error correction. Single-voxel T2-corrected MR spectroscopy was used to measure fat fraction and served as the reference standard. All MR spectroscopy data were postprocessed at a separate institution by an MR physicist who was blinded to MR imaging results. Fat fractions measured with MR imaging and MR spectroscopy were compared statistically to determine the correlation (r2), and the slope and intercept as measures of agreement between MR imaging and MR spectroscopy fat fraction measurements, to determine whether MR imaging can help quantify fat, and examine the importance of T2* correction, spectral modeling of fat, and eddy current correction. Two-sided t tests (significance level, P = .05) were used to determine whether estimated slopes and intercepts were significantly different from 1.0 and 0.0, respectively. Sensitivity and specificity for the classification of clinically significant steatosis were evaluated. Results: Overall, there was excellent correlation between MR imaging and MR spectroscopy for all reconstruction combinations. However, agreement was only achieved when T2* correction, spectral modeling of fat, and magnitude

  4. Multiparametric MR assessment of pediatric brain tumors

    International Nuclear Information System (INIS)

    Tzika, A.A.; Astrakas, L.G.; Zarifi, M.K.; Petridou, N.; Young-Poussaint, T.; Goumnerova, L.; Black, P.McL.; Zurakowski, D.; Anthony, D.C.

    2003-01-01

    MR assessment of pediatric brain tumors has expanded to include physiologic information related to cellular metabolites, hemodynamic and diffusion parameters. The purpose of this study was to investigate the relationship between MR and proton MR spectroscopic imaging in children with primary brain tumors. Twenty-one patients (mean age 9 years) with histologically verified brain tumors underwent conventional MR imaging, hemodynamic MR imaging (HMRI) and proton MR spectroscopic imaging (MRSI). Fourteen patients also had diffusion-weighted MR imaging (DWMRI). Metabolic indices including choline-containing compounds (Cho), total creatine (tCr) and lipids/lactate (L) were derived by proton MRSI, relative cerebral blood volume (rCBV) by HMRI, and apparent tissue water diffusion coefficients (ADC) by DWMRI. Variables were examined by linear regression and correlation as well as by ANOVA. Cho (suggestive of tumor cellularity and proliferative activity) correlated positively with rCBV, while the relationship between Cho and ADC (suggestive of cellular density) was inverse (P<0.001). The relationship between rCBV and ADC was also inverse (P=0.004). Cho and lipids (suggestive of necrosis and/or apoptosis) were not significantly correlated (P=0.51). A positive relationship was found between lipids and ADC (P=0.002). The relationships between Cho, rCBV, ADC and lipids signify that tumor physiology is influenced by the tumor's physical and chemical environment. Normalized Cho and lipids distinguished high-grade from low-grade tumors (P<0.05). Multiparametric MR imaging using MRSI, HMRI and DWMRI enhances assessment of brain tumors in children and improves our understanding of tumor physiology while promising to distinguish higher- from lower-malignancy tumors, a distinction that is particularly clinically important among inoperable tumors. (orig.)

  5. 48 CFR 1332.003 - Simplified acquisition procedures financing.

    Science.gov (United States)

    2010-10-01

    ... procedures financing. 1332.003 Section 1332.003 Federal Acquisition Regulations System DEPARTMENT OF COMMERCE GENERAL CONTRACTING REQUIREMENTS CONTRACT FINANCING 1332.003 Simplified acquisition procedures financing. Contract financing may be provided for purchases made under the authority of FAR Part 13. Contract...

  6. Chemical oceanographic data collected aboard the RYAN CHOUEST in the Gulf of Mexico from 2010-08-13 to 2010-08-23 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0084587)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical oceanographic data were collected aboard the RYAN CHOUEST in the Gulf of Mexico from 2010-08-13 to 2010-08-23 in response to the Deepwater Horizon Oil Spill...

  7. 76 FR 65694 - Non-Market Economy Antidumping Proceedings: Assessment of Antidumping Duties

    Science.gov (United States)

    2011-10-24

    ... DEPARTMENT OF COMMERCE International Trade Administration Non-Market Economy Antidumping... refining its practice to instruct CBP to liquidate such entries at the non-market economy (``NME'')-wide... Non-Market Economy Antidumping Proceedings: Assessment of Antidumping Duties, 76 FR 34046 (June 10...

  8. Dynamical analysis of cylindrically symmetric anisotropic sources in f(R, T) gravity

    Energy Technology Data Exchange (ETDEWEB)

    Zubair, M.; Azmat, Hina [COMSATS Institute of Information Technology, Department of Mathematics, Lahore (Pakistan); Noureen, Ifra [University of Management and Technology, Department of Mathematics, Lahore (Pakistan)

    2017-03-15

    In this paper, we have analyzed the stability of cylindrically symmetric collapsing object filled with locally anisotropic fluid in f(R, T) theory, where R is the scalar curvature and T is the trace of stress-energy tensor of matter. Modified field equations and dynamical equations are constructed in f(R, T) gravity. The evolution or collapse equation is derived from dynamical equations by performing a linear perturbation on them. The instability range is explored in both the Newtonian and the post-Newtonian regimes with the help of an adiabatic index, which defines the impact of the physical parameters on the instability range. Some conditions are imposed on the physical quantities to secure the stability of the gravitating sources. (orig.)

  9. 77 FR 65690 - Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding...

    Science.gov (United States)

    2012-10-30

    ... FEDERAL RESERVE SYSTEM Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction This notice corrects a notice (FR Doc. 2012-26297) published on page 65190 of the issue for Thursday, October 25, 2012. Under the Federal Reserve Bank of Dallas heading, the entry for Bryon Dirk Bagenstos,...

  10. 77 FR 21100 - Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding...

    Science.gov (United States)

    2012-04-09

    ... FEDERAL RESERVE SYSTEM Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction This notice corrects a notice (FR Doc. 2012-7210) published on page 17478 of the issue for Monday, March 26, 2012. Under the Federal Reserve Bank of Richmond heading, the entry for U.S. Immigration Investment...

  11. 78 FR 62633 - Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding...

    Science.gov (United States)

    2013-10-22

    ... FEDERAL RESERVE SYSTEM Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction This notice corrects a notice (FR Doc. 2013-24477) published on page 62333 of the issue for Thursday, October 17, 2013. Under the Federal Reserve Bank of Minneapolis heading, the entry for Karen Neidhardt, Tamp...

  12. Electronic commerce versus traditional commerce

    OpenAIRE

    Dorin Vicentiu Popescu; Manoela Popescu

    2007-01-01

    The internet represents new opportunities for the traditional companies, including the diversification of the given services and also the promotion of the new ones, which are personalized and attractive and they are possible thanks to the information and communication technologies. According to this, the Internet impact, which has allowed the development of a new form of commerce- the commerce via Internet (which is a component of the electronic commerce), against the traditional global comme...

  13. Differentiation of hemangioblastomas from pilocytic astrocytomas using 3-T magnetic resonance perfusion-weighted imaging and MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    She, D.J.; Xing, Z.; Zeng, Z.; Cao, D.R. [First Affiliated Hospital of Fujian Medical University, Department of Radiology, Fuzhou, Fujian (China); Shang, X.Y. [University of California, San Diego, Department of Medicine and the Moores UCSD Cancer Center, La Jolla, CA (United States)

    2015-03-01

    Hemangioblastomas and pilocytic astrocytomas (PAs) present similar imaging features on conventional MR imaging, making differential diagnosis a challenge. The purpose of this study was to evaluate the usefulness of dynamic susceptibility-weighted contrast-enhanced perfusion-weighted imaging (DSC-PWI) and proton MR spectroscopic imaging in the differentiation of hemangioblastomas and PAs. A 3.0-T MR imaging unit was used to perform DSC-PWI and conventional MR imaging on 14 patients with hemangioblastomas and 22 patients with PAs. Four patients with hemangioblastomas and 10 PA patients also underwent proton MR spectroscopy. Parameters of relative peak height (rPH) and relative percentage of signal intensity recovery (rPSR) were acquired by DSC-PWI and variables of N-acetylaspasrtate (NAA)/creatine (Cr), choline (Cho)/Cr, and lactate-lipid (Lac-Lip)/Cr by MR spectroscopy. The sensitivity, specificity, and the area under the receiver operating characteristic curve of all analyzed parameters at respective cutoff values were determined. Higher rPH but lower rPSR values were detected in hemangioblastomas compared to PAs. The NAA/Cr ratio was significantly lower in hemangioblastomas compared with PAs. The threshold values ≥3.2 for rPH provide sensitivity, specificity, positive predictive values, and negative predictive values of 85.7, 95.5, 92.3, and 91.3 %, respectively, for differentiating hemangioblastomas from PAs. The optimal threshold values were ≤0.9 for rPSR and ≤1.5 for NAA/Cr ratios in tumor. Significantly higher rPH and lower NAA/Cr were seen in patients with hemangioblastomas when compared with PA patients, suggesting that DSC-PWI and proton MR spectroscopy are helpful in the characterization and differentiation of these two types of tumors. (orig.)

  14. Gadobutrol versus gadofosveset-trisodium in MR venography of the lower extremities

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldussen, Carsten W.K.P. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); VieCuri Medical Center, Department of Radiology, Venlo (Netherlands); Lam, Yeelai [Maastricht University Medical Center, Department of Vascular Surgery, Maastricht (Netherlands); Ito, Nobutake [National Hospital Organization Tokyo Medical Center, Department of Diagnostic Radiology, Tokyo (Japan); Keio University Hospital, Department of Diagnostic Radiology, Tokyo (Japan); Winkens, Bjorn [Maastricht University, Department of Methodology and Statistics, Maastricht (Netherlands); Kooi, M.E.; Wildberger, Joachim E. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); Maastricht University Medical Center, CARIM - School for Cardiovascular Diseases, Maastricht (Netherlands); Wittens, Cees H.A. [Maastricht University Medical Center, Department of Vascular Surgery, Maastricht (Netherlands); University Hospital RWTH Aachen, Department of Vascular Surgery, Aachen (Germany)

    2017-12-15

    MR venography (MRV) protocols have used bloodpool contrast agents and long scan sequences to identify patients suitable for treatment and preoperatively. However, variable availability of bloodpool contrast agents, high costs and a need to shorten acquisition times for routine MR protocols hamper everyday practice. 20 patients (11 men; mean age 54 ± 11.8 years; body mass index 23.6 ± 2.5) were enrolled in this prospective study. An intra-individual comparison of image quality, interpretation and findings for two different contrast agents (regular gadolinium contrast agent gadobutrol vs. bloodpool contrast agent gadofosveset-trisodium) and two different scan protocols (long acquisition time protocol using a high-resolution fast field echo (FFE) sequence vs. short acquisition time protocol using an ultra-fast gradient echo (GE) sequence) were performed. Image quality (average of 4.94 vs. 4.92 on a five-point scale), interpretation and contrast-to-noise ratio (44 vs. 45) were equal for both contrast agents. Image findings showed no statistical significant differences between the MR protocols or contrast agents (overall p = 0.328). For high-resolution MRV, it is possible to replace gadofosveset-trisodium with gadobutrol. Furthermore, an ultra-fast GE sequence for MRV might considerably shorten acquisition time, without loss of image quality or diagnostic yield. (orig.)

  15. 77 FR 43082 - Federal Acquisition Regulation; Information Collection; Commerce Patent Regulations

    Science.gov (United States)

    2012-07-23

    ... OMB control number. Select the link ``Submit a Comment'' that corresponds with ``Information... dated April 10, 1987. Under the subpart, a contracting officer may insert clauses 52.227-11, Patent...

  16. T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); UMR INSERM 965, Hôpital Lariboisière, 2 Rue Amboise Paré, 75010 Paris (France); Gavini, Jean-Philippe, E-mail: jpgavini@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Placé, Vinciane, E-mail: vinciane.place@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Sebbag, Delphine, E-mail: delphinesebbag@gmail.com [Department of Body and Interventional Imaging, Hôpital Lariboisière, AP-HP, 2 Rue Ambroise Paré, 75475 Paris Cedex 10 (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Rue de Verdun, 75010 Paris (France); Vignaud, Alexandre, E-mail: alexandre.vignaud@cea.fr [LRMN, Neurospin, CEA-SACLAY, Bâtiment 145, 91 191 Gif-sur-Yvette Cedex (France); and others

    2013-11-01

    Objective: To qualitatively and quantitatively compare T2-weighted MR imaging of the liver using volumetric spin-echo with sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) with conventional turbo spin-echo (TSE) sequence for fat-suppressed T2-weighted MR imaging of the liver. Materials and methods: Thirty-three patients with suspected focal liver lesions had SPACE MR imaging and conventional fat-suppressed TSE MR imaging. Images were analyzed quantitatively by measuring the lesion-to-liver contrast-to-noise ratio (CNR), and the signal-to-noise ratio (SNR) of main focal hepatic lesions, hepatic and splenic parenchyma and qualitatively by evaluating the presence of vascular, respiratory motion and cardiac artifacts. Wilcoxon signed rank test was used to search for differences between the two sequences. Results: SPACE MR imaging showed significantly greater CNR for focal liver lesions (median = 22.82) than TSE MR imaging (median = 14.15) (P < .001). No differences were found for SNR of hepatic parenchyma (P = .097), main focal hepatic lesions (P = .35), and splenic parenchyma (P = .25). SPACE sequence showed less artifacts than TSE sequence (vascular, P < .001; respiratory motion, P < .001; cardiac, P < .001) but needed a longer acquisition time (228.4 vs. 162.1 s; P < .001). Conclusion: SPACE MR imaging provides a significantly increased CNR for focal liver lesions and less artifacts by comparison with the conventional TSE sequence. These results should stimulate further clinical studies with a surgical standard of reference to compare the two techniques in terms of sensitivity for malignant lesions.

  17. MR-guided MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Tratting, S.; Breitenseher, M.; Pretterklieber, M.; Kontaxis, G.; Rand, T.; Imhof, H.

    1996-01-01

    Purpose: To develop an MR-guided technique for joint puncture in MR arthrography of the shoulder and to confirm the intracapsular position of the needle tip by visualization of the flow of contrast media into the joint. Materials and methods: Three unfixed human shoulder joint specimens were examined on a 1.0 T unit. The optimal point of entrance and depth for joint puncture were estimated by means of MR-compatible markers on the skin. Needle orientation and localization of the needle tip (MR-compatible 22-gauge needle) in the shoulder joint were monitored by rapid localizer gradient-echo sequences in two orthogonal planes. To confirm the intracapsular position of the needle tip, diluted gadolinium-DTPA was administered via a long connecting tube and the flow of contrast media into the joint was viewed directly on an LCD screen using real-time MR imaging (local look technique). Results: The MR-compatible markers on the skin allowed determination of the optimal point of entrance and estimation of the depth for joint puncture. Passive visualization of the MR-compatible needle due to spin dephasing and signal loss provided adequate localization of the intra-articular needle tip position in all specimens, although significant artefacts were present on rapid localizer gradient-echo sequences with an increase in width of the apparent needle shaft. Real-time MR imaging of the flow of contrast media was possible using the local look technique and the LCD screen of the MR unit and allowed confirmation of the intracapsular position. Conclusion: MR-guided joint puncture and real-time MR-assisted contrast media application results in improved MR arthrography and may replace conventional fluoroscopic guidance. (orig.) [de

  18. SU-F-J-149: Beam and Cryostat Scatter Characteristics of the Elekta MR-Linac

    Energy Technology Data Exchange (ETDEWEB)

    Duglio, M; Towe, S; Roberts, D [Elekta Limited, Crawley, West Sussex (United Kingdom)

    2016-06-15

    Purpose: The Elekta MR-Linac combines a digital linear accelerator system with a 1.5T Philips MRI machine. This study aimed to determine key characteristic information regarding the MR-Linac beam and in particular it evaluated the effect of the MR cryostat on the out of field scatter dose. Methods: Tissue phantom ratios, profiles and depth doses were acquired in plastic water with an IC-profiler or with an MR compatible water tank using multiple system configurations (Full (B0= 1.5T), Full (B0=0T) and No cryostat). Additionally, an in-house CAD based Monte Carlo code based on Penelope was used to provide comparative data. Results: With the cryostat in place and B0=0T, the measured TPR for the MR Linac system was 0.702, indicating an energy of around 7MV. Without the cryostat, the measured TPR was 0.669. For the Full (B0=0T) case, out of field dose at a depth of 10 cm in the isocentric plane, 5 cm from the field edge was 0.8%, 3.1% and 5.4% for 3×3 cm{sup 2}, 10×10 cm{sup 2} and 20×20 cm{sup 2} fields respectively.The out of field dose (averaged between 5 cm and 10 cm beyond the field edges) in the “with cryostat” case is 0.78% (absolute difference) higher than without the cryostat for clinically relevant field sizes (i.e. 10×10 cm{sup 2}) and comparable to measured conventional 6MV treatment beams at a depth of 10 cm (within 0.1% between 5 cm and 6 cm from field edge). At dose maximum and at 5 cm from the field edge, the “with cryostat” out of field scatter for a 10×10 cm{sup 2} field is 1.5% higher than “without cryostat', with a modest increase (0.9%) compared to Agility 6MV in the same conditions. Conclusion: The study has presented typical characteristics of the MR-Linac beam and determined that out of field dose is comparable to conventional treatment beams. All authors are employed by Elekta Ltd., who are developing an MR-Linac.

  19. A comparative study of MR imaging scores and MR perfusion imaging in pre-operative grading of intracranial gliomas

    International Nuclear Information System (INIS)

    Wu Honglin; Chen Junkun; Zhang Zongjun; Lu Guangming; Chen Ziqian; Wang Wei; Ji Xueman; Tang Xiaojun; Li Lin

    2005-01-01

    Objective: To compare the accuracy of MR imaging scores with MR perfusion imaging in pre-operative grading of intracranial gliomas. Methods: Thirty patients with intracranial gliomas (8 low-grade and 22 high-grade, according to WHO criteria) were examined with MR perfusion imaging pre-operatively. The lesions were evaluated by using an MR imaging score based on nine criteria. rCBV of the lesions were calculated by comparing the CBV of the lesion and that of contralateral normal white matter. The scores and ratios in high-grade and low-grade tumours were compared. Results: The MR imaging score of low grade (grades I and II) gliomas (0.67±0.29) were significantly lower than that of grades III (1.32 ± 0.47) (t=-3.48, P=0.003) and IV (1.56 ± 0.20) (t=-7.36, P=0.000) gliomas. There was no statistical difference when MR imaging scores of grades III and IV gliomas (t=-1.39, P=0.182) were compared. The maximum rCBV ratio of low grade (grades I and II) gliomas (2.38 ± 0.66 ) were significantly lower than that of grades III (5.81 ± 3.20) (t=-3.57, P=0.003) and IV (6.99 ± 2.47) (t=-5.09, P=0.001). There was no statistical difference when rCBV ratios of grades III and IV (t =-0.93, P=0.365) gliomas were compared. The accuracy of MR imaging scores in the noninvasive grading of untreated gliomas was all most the same as that of MR perfusion imaging (90.00% vs 89.29%). Conclusion: The MR imaging scores and MR perfusion imaging are two very useful tools in the evaluation of the histopathologic grade of cerebral gliomas. The overall accuracy in the noninvasive grading of gliomas may be imp roved if MR imaging scores and MR perfusion imaging are combined. (authors)

  20. Från outsiderfilmmakare till etablerad indieregissör : David Lynch, Jim Jarmusch och Steven Soderbergh

    OpenAIRE

    Simberg, Maximilian

    2014-01-01

    Det här arbetet behandlar kreativ frihet och konstnärligt oberoende i filmskapande, utgående från begreppet independent film och regissörerna David Lynch, Jim Jarmusch och Steven Soderbergh. Den centrala frågeställningen är hur det har varit möjligt för en filmkonstnär att uppnå konstnärligt oberoende och samtidigt ha en långlivad och framgångsrik karriär. Arbetets fokus ligger på de tre regissörernas genombrottsfilmer; Eraserhead, Stranger Than Paradise och sex, lies, and videotape, och förs...

  1. Airborne Gravity: NGS' Gravity Data for CS08 (2015)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Airborne gravity data for CS08 collected in 2006 over 1 survey. This data set is part of the Gravity for the Re-definition of the American Vertical Datum (GRAV-D)...

  2. Validation of a simultaneous PET/MR system model for PET simulation using GATE

    International Nuclear Information System (INIS)

    Monnier, Florian; Fayad, Hadi; Bert, Julien; Schmidt, Holger; Visvikis, Dimitris

    2015-01-01

    Simultaneous PET/MR acquisition shows promise in a range of applications. Simulation using GATE is an essential tool that allows obtaining the ground truth for such acquisitions and therefore helping in the development and the validation of innovative processing methods such as PET image reconstruction, attenuation correction and motion correction. The purpose of this work is to validate the GATE simulation of the Siemens Biograph mMR PET/MR system. A model of the Siemens Biograph mMR was developed. This model includes the geometry and spatial positioning of the crystals inside the scanner and the characteristics of the detection process. The accuracy of the model was tested by comparing, on a real physical phantom study, GATE simulated results to reconstructed PET images using measured results obtained from a Siemens Biograph mMR system. The same parameters such as the acquisition time and phantom position inside the scanner were fixed for our simulations. List-mode outputs were recovered in both cases and reconstructed using the OPL-EM algorithm. Several parameters were used to compare the two reconstructed images such as profile comparison, signal-to-noise ratio and activity contrast analysis. Finally patient acquired MR images were segmented and used for the simulation of corresponding PET images. The simulated and acquired sets of reconstructed phantom images showed close emission values in regions of interest with relative differences lower than 5%. The scatter fraction was within a <3% agreement. Close matching of profiles and contrast indices were obtained between simulated and corresponding acquired PET images. Our results indicate that the GATE developed Biograph mMR model is accurate in comparison to the real scanner performance and can be used for evaluating innovative processing methods for applications in clinical PET/MR protocols.

  3. New proposal for non-linear ghost-free massive F(R) gravity: Cosmic acceleration and Hamiltonian analysis

    International Nuclear Information System (INIS)

    Klusoň, Josef; Nojiri, Shin'ichi; Odintsov, Sergei D.

    2013-01-01

    We propose new version of massive F(R) gravity which is natural generalization of convenient massive ghost-free gravity. Its Hamiltonian formulation in scalar-tensor frame is developed. We show that such F(R) theory is ghost-free. The cosmological evolution of such theory is investigated. Despite the strong Bianchi identity constraint the possibility of cosmic acceleration (especially, in the presence of cold dark matter) is established. Ghost-free massive F(R,T) gravity is also proposed

  4. 78 FR 57853 - Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding...

    Science.gov (United States)

    2013-09-20

    ... FEDERAL RESERVE SYSTEM Change in Bank Control Notices; Formations of, Acquisitions by, and Mergers of Bank Holding Companies; Correction This notice corrects a notice (FR Doc. 2013-22047) published on pages 55716 and 55717 of the issue for Wednesday, September 11, 2013. Under the Federal Reserve Bank of New York heading, the entry for Donald J....

  5. Intracranial CSF flow on cine-MR. 2. Qualitative analysis in CSF dynamics by MR signal ratio of CSF to fat tissue in healthy subjects and patients with aqueduct stenosis

    International Nuclear Information System (INIS)

    Kadowaki, Chikafusa; Hara, Mitsuhiro; Takeuchi, Kazuo; Saito, Isamu

    1994-01-01

    Changes in MR signal intensities (SIs) of CSF and relative MR signal ratios (SRs) of intraventricular CSF to fat tissue were evaluated in 5 healthy adults on cine MR images during a cardiac cycle in a study of normal intracranial CSF dynamics. The altered patterns of MR SIs and SRs in 6 patients with aqueduct stenosis were compared with normal CSF flow patterns in a demonstration of CSF dynamics changes. MR SIs of CSF within the ventricles were measured on each cine image obtained by cardiac gated, multiframe, cine MR imaging. Chronological changes in MR SIs and SRs during a cardiac cycle were compared with the actual CSF flow visualized on real cine images. In normal CSF circulation, MR SIs of CSF within the ventricles were reduced quickly following an R-wave on ECG to 15% of the R-R interval, after which SIs fluctuated slightly. These changes in MR SIs of CSF could only be related to the pulsatile CSF flow through the foramen of Monro into the anterior part of the third ventricle during early cardiac systole. MR SRs of CSF to fat tissue fluctuated according to the actual CSF flow within the ventricles during a cardiac cycle. MR SRs in the third ventricle decreased to 20-30% of the R-R interval following the R-wave due to downward CSF flow during early cardiac systole, and decreased again from late cardiac systole to diastole due to caudal CSF flow in the third ventricle. In the fourth ventricle, MR SRs of CSF decreased to 60-80% of the R-R interval because of the CSF flow through the aqueduct during cardiac diastole. In patients with aqueduct stenosis, MR SRs of CSF within the ventricles fluctuated randomly, and the amplitude of MR SRs was also greater than in subjects with a patent aqueduct. These changes were identified as turbulence and stagnation due to obstruction in the CSF pathway. Analysis of chronological changes in MR signal ratios of CSF to fat is useful in demonstrating the pathophysiologic features of intracranial CSF dynamics. (author) 52 refs

  6. Data acquisition system realization for H1 experiment

    International Nuclear Information System (INIS)

    Del Buono, L.

    1989-06-01

    The acquisition and trigger system for H1 liquid argon calorimeter deals with severe constraints which have to be taken into account. We describe the system which results from these constraints, emphasizing the solutions adopted to meet the specificities of the detector and the difficult experimental conditions at HERA: high physical background (10 4-5 Hz), physics and background events pile up (10%), large crossing frequency of proton and electron bunches (10.4 MHz). Next, we present a detailed description of the acquisition and online control scheme used during the calorimetry tests in SPS beam, at CERN. This test system, prefiguring the final one (which will start to work at the end of 1989), includes a fast frontal processor CAB (taking charge of the electronics read out and sequencing, and furthermore producing simple histograms). The CAB is controlled by a Micro Vax computer which realizes the user interface, allowing a quick visualisation and verification of the acquired data, these functions being performed in multitasking environment [fr

  7. MR diagnosis of temporomandibular arthrosis

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Shigeaki [Kagoshima Univ. (Japan). Faculty of Dentistry

    1996-09-01

    This review described lesions of articular disk and its surrounding tissues revealed by MR examination in temporomandibular arthrosis, and problems and limits of the examination. Apparatus and imaging methods: Spin echo method was generally used and gradient echo method was alternatively used. Author`s apparatus was 1.5 tesla Signa, Advantage type, equipped with surface coil for temporomandibular joint. Imaging conditions were T1-weighted spin echo method, T2-weighted fast spin echo method, spoiled GRASS (gradient recalled acquisition in the steady state) method and GRASS method. MR findings of articular disk: MR images of normal and abnormal temporomandibular joint were presented together with computed radiographic findings. The role of dynamic imaging was described for evaluation and analysis of the joint functioning. MR findings of surrounding tissues of the disk: Dynamic MRI of the tissues was found useful to see whether the cause of pain was present inside or outside of the articular capsule. Joint effusion could not be fully imaged in T2-weighted conditions. (K.H.)

  8. MR diagnosis of temporomandibular arthrosis

    International Nuclear Information System (INIS)

    Suenaga, Shigeaki

    1996-01-01

    This review described lesions of articular disk and its surrounding tissues revealed by MR examination in temporomandibular arthrosis, and problems and limits of the examination. Apparatus and imaging methods: Spin echo method was generally used and gradient echo method was alternatively used. Author's apparatus was 1.5 tesla Signa, Advantage type, equipped with surface coil for temporomandibular joint. Imaging conditions were T1-weighted spin echo method, T2-weighted fast spin echo method, spoiled GRASS (gradient recalled acquisition in the steady state) method and GRASS method. MR findings of articular disk: MR images of normal and abnormal temporomandibular joint were presented together with computed radiographic findings. The role of dynamic imaging was described for evaluation and analysis of the joint functioning. MR findings of surrounding tissues of the disk: Dynamic MRI of the tissues was found useful to see whether the cause of pain was present inside or outside of the articular capsule. Joint effusion could not be fully imaged in T2-weighted conditions. (K.H.)

  9. Solar System constraints on a cosmologically viable f(R) theory

    Energy Technology Data Exchange (ETDEWEB)

    Bisabr, Yousef, E-mail: y-bisabr@srttu.ed [Department of Physics, Shahid Rajaee Teacher Training University, Lavizan, Tehran 16788 (Iran, Islamic Republic of)

    2010-01-18

    Recently, a model f(R) theory is proposed (Miranda et al. (2009)) which is cosmologically viable and distinguishable from LAMBDACDM. We use chameleon mechanism to investigate viability of the model in terms of Solar System experiments.

  10. Fetal kidney programming by severe food restriction: effects on structure, hormonal receptor expression and urinary sodium excretion in rats.

    Science.gov (United States)

    Vaccari, Barbara; Mesquita, Flavia F; Gontijo, Jose A R; Boer, Patricia A

    2015-03-01

    The present study investigates, in 23-day-old and adult male rats, the effect of severe food restriction in utero on blood pressure (BP), and its association with nephron structure and function changes, angiotensin II (AT1R/AT2R), glucocorticoid (GR) and mineralocorticoid (MR) receptor expression. The daily food supply to pregnant rats was measured and one group (n=15) received normal quantity of food (NF) while the other received 50% of that (FR50%) (n=15). Kidneys were processed to AT1R, AT2R, MR, and GR immunolocalization and for western blotting analysis. The renal function was estimated by creatinine and lithium clearances in 12-week-old offspring. By stereological analyses, FR50% offspring present a reduction of nephron numbers (35%) with unchanged renal volume. Expression of AT1R and AT2R was significantly decreased in FR50% while the expression of GR and MR increased in FR50%. We also verified a pronounced decrease in urinary sodium excretion accompanied by increased BP in 12-week-old FR50% offspring. The current data suggest that changes in renal function are conducive to excess sodium tubule reabsorption, and this might potentiate the programming of adult hypertension. It is plausible to arise in the current study an association between decreasing natriuresis, reciprocal changes in renal AngII and steroid receptors with the hypertension development found in FR50% compared with age-matched NF offspring. © The Author(s) 2013.

  11. Building eCommerce sites with Drupal commerce cookbook

    CERN Document Server

    Carter, Richard

    2013-01-01

    Building eCommerce Sites with Drupal Commerce Cookbook is written in a helpful, practical style with numerous hands-on recipes to help you build attractive eCommerce sites.This book is primarily for store owners and web designers with little or no experience of Drupal and Drupal Commerce who want to build and customise a store in Drupal Commerce. You will have a basic knowledge of websites, but you don't need to be familiar with Drupal or PHP. However, this book would also suit experienced Drupal and Ubercart users who want to migrate to or build a Drupal Commerce store

  12. Envelope composition of Salmonella typhimurium 395 MS and 395 MR10 assesses by X-ray photoelectron spectroscopy (ESCA)

    International Nuclear Information System (INIS)

    Magnusson, K.F.; Johansson, L.

    1977-01-01

    The Salmonella typhimurium 395 MS and MR10 bacteria and lipopolysaccharide (LPS) were studied by X-ray photoelectron spectroscopy with the aid of the ESCA technique for the in situ analysis of chemical elements (C, O and N) at the surface. The nitrogen peak was large in both bacteria implying the presence of protein in the very outer part of the bacterial envelope due to the surface-sensitive measurement. The nitrogen peak was larger in the MR10 than in the MS bacteria, presumably reflecting an increased exposure of proteins concomitantly with the reduction of the LPS in MR10. After corrections for background and sensitivity of detection the relative intensities of the peaks agreed appreciably well with the proposed chemical structure of the LPS, indicating that at least semiquantitative relationships between the elements were obtained. (author)

  13. 78 FR 48298 - Amendment of Class E Airspace; Commerce, TX

    Science.gov (United States)

    2013-08-08

    ...-0269; Airspace Docket No. 13-ASW-3] Amendment of Class E Airspace; Commerce, TX AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final rule. SUMMARY: This action amends Class E airspace at Commerce, TX. Additional controlled airspace is necessary to accommodate new Area Navigation (RNAV...

  14. 3S-R10 automated RBS system

    International Nuclear Information System (INIS)

    Norton, G.A.; Schroeder, J.B.; Klody, G.M.; Strathman, M.D.

    1989-01-01

    The NEC 3S-R10 automated RBS spectrometer system includes the features required for routine application of Rutherford backscattering (RBS) and related techniques for materials analysis in both research and industrial settings. The NEC Model 3SDH Pelletron accelerator system provides stable, monoenergetic beams of helium ions up to 3.3 MeV and protons to 2.2 MeV and has heavy ion capability. The analytical end station is the fully computerized Charles Evans and Associates Model RBS-400. Automated features include sample positioning (precision 4-axis goniometer), channeling alignment, polar plot generation, and data acquisition and reduction. Computer automation of accelerator and chamber functions includes storage and recall of operating parameters. Unattended data acquisition, e.g., overnight or over a weekend, is possible for up to 100 samples per batch for random orientation, rotating random or channeling analyses at any sample location. Single samples may be up to 50 cm in diameter. A laser for sample alignment and a TV for video monitoring are included. Simultaneous detection (up to 4 detectors) at normal and grazing angles, external control of grazing angle detector position, and transmission scattering capabiltiy enhance system flexibility. The system is also compatible with PIXE, NRA, and hydrogen forward-backscattering analyses. Data reduction is part of the computer system, which features displays (several formats) and manipulation of up to five spectra at one time using constant multipliers or point by point operations between spectra. (orig.)

  15. B00188: NOS Hydrographic Survey , 1989-08-10

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The National Oceanic and Atmospheric Administration (NOAA) has the statutory mandate to collect hydrographic data in support of nautical chart compilation for safe...

  16. Study of Antigravity in an F(R) Model and in Brans-Dicke Theory with Cosmological Constant

    OpenAIRE

    Oikonomou, V. K.; Karagiannakis, N.

    2014-01-01

    We study antigravity, that is having an effective gravitational constant with a negative sign, in scalar-tensor theories originating from $F(R)$-theory and in a Brans-Dicke model with cosmological constant. For the $F(R)$ theory case, we obtain the antigravity scalar-tensor theory in the Jordan frame by using a variant of the Lagrange multipliers method and we numerically study the time dependent effective gravitational constant. As we shall demonstrate by using a specific $F(R)$ model, altho...

  17. 77 FR 13013 - Defense Federal Acquisition Regulation Supplement; Technical Amendments

    Science.gov (United States)

    2012-03-05

    ... Organization Government Procurement Agreement and the Free Trade Agreements, as determined by the United States... 252 Government procurement. Ynette R. Shelkin, Editor, Defense Acquisition Regulations System...

  18. Solar System constraints on a cosmologically viable f(R) theory

    International Nuclear Information System (INIS)

    Bisabr, Yousef

    2010-01-01

    Recently, a model f(R) theory is proposed (Miranda et al. (2009)) which is cosmologically viable and distinguishable from ΛCDM. We use chameleon mechanism to investigate viability of the model in terms of Solar System experiments.

  19. Quantitative PET imaging with the 3T MR-BrainPET

    International Nuclear Information System (INIS)

    Weirich, C.; Scheins, J.; Lohmann, P.; Tellmann, L.; Byars, L.; Michel, C.; Rota Kops, E.; Brenner, D.; Herzog, H.; Shah, N.J.

    2013-01-01

    The new hybrid imaging technology of MR-PET allows for simultaneous acquisition of versatile MRI contrasts and the quantitative metabolic imaging with PET. In order to achieve the quantification of PET images with minimal residual error the application of several corrections is crucial. In this work we present our results on quantification with the 3T MR BrainPET scanner

  20. Defense Acquisition Reform: Where Do We Go From Here? A Compendium of Views by Leading Experts

    Science.gov (United States)

    2014-10-02

    55 10. Mr. Paul Francis ...International Studies, and research assistants at the Belfer Center for Science and International Affairs, Harvard Kennedy School including Peter Bacon ...direction of Paul L. Francis . Published 22 years ago, it is fully relevant today. Unlike the many acquisition studies that preceded it, this report

  1. MR of the small bowel with a biphasic oral contrast agent (polyethylene glycol): technical aspects and findings in patients affected by Crohn's disease.

    Science.gov (United States)

    Laghi, Andrea; Paolantonio, Pasquale; Iafrate, Franco; Borrelli, Osvaldo; Dito, Lucia; Tomei, Ernesto; Cucchiara, Salvatore; Passariello, Roberto

    2003-01-01

    To report our experience using MR of the small bowel with polyethylene glycol (PEG) solution as an oral contrast agent in a population of adults and children with known Crohn's disease. 40 patients (29 males; 11 females), 15 adults (age range 24-52 years) and 25 children (age range 5-17 years), with known Crohn's disease, underwent MR of the small bowel using a supeconductive 1.5 T magnet, and polyethylene glycol solution as an oral contrast agent. The fixed amount of contrast agent was 750-1000 ml for adults and 10 ml/kg of body weight for children. The Crohn's Disease Activity Index (CDAI) was available in all patients. Our study protocol included the acquisition of T2-weighted half-Fourier single-shot turbo spin-echo (HASTE) sequences and true fast imaging in the steady-state precession (true-FISP) sequences, followed by the acquisition of "spoiled" 2D gradient echo T1-weighted sequences with fat suppression (FLASH, fast low-angle shot) or alternatively "spoiled" 3D (VIBE, volume interpolated breath-hold examination), acquired 70 seconds after intravenous administration of gadopentetate dimeglumine (Gd-DTPA) (0,1 mmol/kg). A specific MR score was created and calculated for each patient and was compared by means of the Spearman rank with CDAI. In all patients no significant side effects were observed and the MR examination was well tolerated even by paediatric patients. In all cases MR showed a small bowel wall thickening (> 4 mm) in the terminal ileum, with lumen stenosis in 26 patients. In 3 cases pathological segments proximal to the terminal ileum were observed and in another 3 cases caecal involvement was visible. The MR examination was able to show abnormalities of perivisceral fat tissue in 15 patients, mesenteric lymphadenopathy in 1 patient and abdominal abscess in 1 case. The Spearman rank showed a statistically significant correlation between CDAI and the MR score (r = 0.91, P = 0,0001). MR using PEG as an oral contrast agent could be considered a test

  2. Electronic Commerce - Chancen und Herausforderungen für Baden-Württemberg : Projektbericht

    OpenAIRE

    Fuchs, Gerhard; Renz, Christian; Teutsch, Barbara

    2002-01-01

    „Electronic Commerce“ – elektronischer Handel – ist seit Ende der 90er Jahre im Zuge der Gesamtdiskussion um den Bereich der „New Economy“ Thema von Wirtschaft, Politik und Öffentlichkeit. Verbunden mit Hoffnungen auf hohes Umsatzwachstum, getragen von einem enormen technischen Potenzial, zeichneten eine Reihe von Prognosen das euphorische Bild eines explosionsartigen Anstieges des Volumens von Electronic Commerce. Doch nicht erst seit dem „Platzen der E-Commerce-Blase“ im Jahr 2001 werden kr...

  3. 75 FR 33752 - Defense Federal Acquisition Regulation Supplement; Organizational Conflicts of Interest in Major...

    Science.gov (United States)

    2010-06-15

    ... Conflicts of Interest in Major Defense Acquisition Programs AGENCY: Defense Acquisition Regulations System... extended an additional 30 days to provide additional time for interested parties to review the proposed... interested parties to review the proposed DFARS changes. Ynette R. Shelkin, Editor, Defense Acquisition...

  4. Chemical and laboratory analyses oceanographic data collected aboard the Wes Bordelon in the Gulf of Mexico from 2010-08-18 to 2010-08-22 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0074863)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical and laboratory analyses oceanographic data were collected aboard the Wes Bordelon in the Gulf of Mexico from 2010-08-18 to 2010-08-22 in response to the...

  5. In-house R&D and External Knowledge Acquisition What Makes Chinese Firms Productive?

    OpenAIRE

    Böing, Philipp; Müller, Elisabeth; Sandner, Philipp

    2013-01-01

    This paper analyses the influence of in-house R&D and external knowledge acquisition on the total factor productivity (TFP) of listed Chinese firms for the time period 2001-2010. We find a quantitatively important positive effect of in-house R&D. The achieved level of technological sophistication of Chinese firms is sufficient to benefit from R&D collaboration with domestic partners. We do not find a significant effect for employing inventors with access to international knowledge or for coll...

  6. Temperature, salinity and other variables collected from discrete sample and profile observations using CTD, bottle and other instruments from the METEOR in the North Atlantic Ocean from 1999-08-13 to 1999-08-31 (NODC Accession 0115603)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NODC Accession 0115603 includes chemical, discrete sample, physical and profile data collected from METEOR in the North Atlantic Ocean from 1999-08-13 to 1999-08-31...

  7. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the Ferrel in the Gulf of Mexico from 2010-08-03 to 2010-08-11 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069063)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the Ferrel in the Gulf of Mexico from 2010-08-03 to 2010-08-11 in...

  8. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the Ferrel in the Gulf of Mexico from 2010-08-18 to 2010-08-23 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069065)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the Ferrel in the Gulf of Mexico from 2010-08-18 to 2010-08-23 in...

  9. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the Ferrel in the Gulf of Mexico from 2010-08-13 to 2010-08-17 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069064)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the Ferrel in the Gulf of Mexico from 2010-08-13 to 2010-08-17 in...

  10. MR imaging of pituitary macroadenomas before and after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Hald, J.K.; Nakstad, P.H.; Kollevold, T.; Bakke, S.J.; Skalpe, I.O.

    1992-01-01

    MR findings before and after transsphenoidal surgery were evaluated in 6 cases. T1-weighted (TR/TE 600/20) sagittal and coronal images with 2 or 4 acquisitions were obtained, using 3-mm slice thickness and 0.3-mm interslice gaps. Of 18 MR examinations, 13 included coronal i.v. contrast medium enhanced images. Image quality, sinus cavernosus invasion, identification of normal pituitary tissue and tumor size were examined. All MR studied clearly demonstrated the macroadenomas whether 2 or 4 acquisitions were used, and whether i.v. contrast medium was administered or not. Surgically confirmed sinus cavernosus infiltration was seen in 4 patients. The pituitary stalk was identified separate from the tumor in 2 patients, and the gland in one. There was reduction in tumor size over time, indicating that final radiologic assessment after transsphenoidal surgery is best performed 4 to 6 months postoperatively. It should not be necessary to routinely include i.v. contrast medium injection in the postoperative evaluation of macroadenomas. (orig.)

  11. 75 FR 5764 - Honey from the People's Republic of China: Initiation of New Shipper Antidumping Duty Reviews

    Science.gov (United States)

    2010-02-04

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-863] Honey from the People's... (``NSRs'') of the antidumping duty order on honey from the People's Republic of China (``PRC''), received... from the People's Republic of China, 66 FR 63670 (December 10, 2001) (``Order''). On December 10, 2009...

  12. 75 FR 47540 - Extension of the Award Period for Certain Minority Business Enterprise Centers

    Science.gov (United States)

    2010-08-06

    ... DEPARTMENT OF COMMERCE Minority Business Development Agency [Docket No.: 100730316-0318-02... Development Agency, Commerce. ACTION: Notice. SUMMARY: The Minority Business Development Agency (MBDA... Alabama MBEC Mobile Area Chamber of State of Alabama........ 71 FR 42351, as amended by 71 FR 45773 and by...

  13. Influence of f(R) models on the existence of anisotropic self-gravitating systems

    Energy Technology Data Exchange (ETDEWEB)

    Yousaf, Z.; Sharif, M.; Bhatti, M.Z. [University of the Punjab, Department of Mathematics, Lahore (Pakistan); Ilyas, M. [University of the Punjab, Centre for High Energy Physics, Lahore (Pakistan)

    2017-10-15

    This paper aims to explore some realistic configurations of anisotropic spherical structures in the background of metric f(R) gravity, where R is the Ricci scalar. The solutions obtained by Krori and Barua are used to examine the nature of particular compact stars with three different modified gravity models. The behavior of material variables is analyzed through plots and the physical viability of compact stars is investigated through energy conditions. We also discuss the behavior of different forces, equation of state parameter, measure of anisotropy and Tolman-Oppenheimer-Volkoff equation in the modeling of stellar structures. The comparison from our graphical representations may provide evidence for the realistic and viable f(R) gravity models at both theoretical and the astrophysical scale. (orig.)

  14. Use of a newly developed piezoelectrically driven drilling machine for MR-guided bone biopsies

    International Nuclear Information System (INIS)

    Fritzsch, D.; Werner, A.; Kahn, T.

    2002-01-01

    Purpose: Development and clinical testing of an MR-compatible bone biopsy system, to enable the sample collection from osteosclerotic or subcortical lesions for histological investigation under MR control. Materials and Methods: A piezoelectrically driven drilling machine was constructed and tested in connection with an MR-compatible bone biopsy set in a vertical open MR scanner (0.5 T) on a phantom and 10 patients with ambiguous bone lesions. Images were obtained using T 1 -weighted spin-echo sequences and, in case of real-time imaging, a fast spoiled gradient-echo sequence. Results: The influence of the enabled motor (RF-interference) leads to a reduction of the signal to noise ratio of the images, but can be minimised by appropriate measures. The observed slight field distorsions do not affect the image quality during real time acquisition in a substantial manner. No complications occurred. The extracted biopsy material was sufficient and of good quality. Conclusions: In spite of slightly restricted image quality, the described drilling machine combined with the bone biopsy set is well suited for MR-guided bone biopsies, which require the application of a motor driven drill. Its application within an interventional MR scanner is safe and its handling simple and manageable. (orig.) [de

  15. OPAL: selection and acquisition of LEP data

    International Nuclear Information System (INIS)

    Le Du, P.

    1985-01-01

    The OPAL project (Omni Purpose aparatus for LEP) is presented. It will be a frame and an example to explain the main problems and limitations concerning the mode of event selection, acquisition and information transfer to the final registering system. A quick review of the different problems related to data selection and acquisition is made [fr

  16. Constraining models of f(R) gravity with Planck and WiggleZ power spectrum data

    International Nuclear Information System (INIS)

    Dossett, Jason; Parkinson, David; Hu, Bin

    2014-01-01

    In order to explain cosmic acceleration without invoking ''dark'' physics, we consider f(R) modified gravity models, which replace the standard Einstein-Hilbert action in General Relativity with a higher derivative theory. We use data from the WiggleZ Dark Energy survey to probe the formation of structure on large scales which can place tight constraints on these models. We combine the large-scale structure data with measurements of the cosmic microwave background from the Planck surveyor. After parameterizing the modification of the action using the Compton wavelength parameter B 0 , we constrain this parameter using ISiTGR, assuming an initial non-informative log prior probability distribution of this cross-over scale. We find that the addition of the WiggleZ power spectrum provides the tightest constraints to date on B 0 by an order of magnitude, giving log 10 (B 0 ) < −4.07 at 95% confidence limit. Finally, we test whether the effect of adding the lensing amplitude A Lens and the sum of the neutrino mass ∑m ν is able to reconcile current tensions present in these parameters, but find f(R) gravity an inadequate explanation

  17. Chemical and physical oceanographic profile data collected from CTD casts aboard the SEWARD JOHNSON in the North Atlantic Ocean and Gulf of Mexico from 2010-08-04 to 2010-08-08 in response to the Deepwater Horizon oil spill event (NODC Accession 0068597)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical and physical oceanographic profile data were collected aboard the SEWARD JOHNSON in the North Atlantic Ocean and Gulf of Mexico from 2010-08-04 to...

  18. Image reconstruction of mMR PET data using the open source software STIR

    Energy Technology Data Exchange (ETDEWEB)

    Markiewicz, Pawel [Centre for Medical Image Computing, University College London, London (United Kingdom); Thielemans, Kris [Institute of Nuclear Medicine, University College London, London (United Kingdom); Burgos, Ninon [Centre for Medical Image Computing, University College London, London (United Kingdom); Manber, Richard [Institute of Nuclear Medicine, University College London, London (United Kingdom); Jiao, Jieqing [Centre for Medical Image Computing, University College London, London (United Kingdom); Barnes, Anna [Institute of Nuclear Medicine, University College London, London (United Kingdom); Atkinson, David [Centre for Medical Imaging, University College London, London (United Kingdom); Arridge, Simon R [Centre for Medical Image Computing, University College London, London (United Kingdom); Hutton, Brian F [Institute of Nuclear Medicine, University College London, London (United Kingdom); Ourselin, Sébastien [Centre for Medical Image Computing, University College London, London (United Kingdom); Dementia Research Centre, University College London, London (United Kingdom)

    2014-07-29

    Simultaneous PET and MR acquisitions have now become possible with the new hybrid Biograph Molecular MR (mMR) scanner from Siemens. The purpose of this work is to create a platform for mMR 3D and 4D PET image reconstruction which would be freely accessible to the community as well as fully adjustable in order to obtain optimal images for a given research task in PET imaging. The proposed platform is envisaged to prove useful in developing novel and robust image bio-markers which could then be adapted for use on the mMR scanner.

  19. Image reconstruction of mMR PET data using the open source software STIR

    International Nuclear Information System (INIS)

    Markiewicz, Pawel; Thielemans, Kris; Burgos, Ninon; Manber, Richard; Jiao, Jieqing; Barnes, Anna; Atkinson, David; Arridge, Simon R; Hutton, Brian F; Ourselin, Sébastien

    2014-01-01

    Simultaneous PET and MR acquisitions have now become possible with the new hybrid Biograph Molecular MR (mMR) scanner from Siemens. The purpose of this work is to create a platform for mMR 3D and 4D PET image reconstruction which would be freely accessible to the community as well as fully adjustable in order to obtain optimal images for a given research task in PET imaging. The proposed platform is envisaged to prove useful in developing novel and robust image bio-markers which could then be adapted for use on the mMR scanner.

  20. MR imaging of septic sacroiliitis

    Energy Technology Data Exchange (ETDEWEB)

    Stuerzenbecher, A.; Hamm, B.; Bollow, M. [Humboldt-Universitaet, Berlin (DD). Bereich Medizin (Charite); Braun, J. [Freie Univ. Berlin (Germany). Universitaetsklinikum Benjamin Franklin; Paris, S. [Unfallkrankenhaus Berlin (Germany). Dept. of Radiology; Biedermann, T. [Krankenhaus Berlin-Buch (Germany). II. Kinderklinik

    2000-08-01

    Objective. To investigate the diagnostic value of magnetic resonance (MR) imaging in detecting septic sacroiliitis and to determine whether the MR characteristics allow this entity to be differentiated from sacroiliitis in spondylarthropathy (SpA).Patients and design. The imaging findings of 11 patients with septic sacroiliitis were retrospectively analyzed by two experienced radiologists. Radiographic surveys of the pelvis as well as computed tomography (CT) and MR images of the sacroiliac joints were available in all cases. Seven of the patients additionally underwent a follow-up MR examination. The MR imaging protocol comprised combinations of coronal and transverse T1-weighted spin-echo (SE) or fast SE sequences, T2-weighted gradient-echo (GE) sequences and short tau inversion recovery sequence (STIR) sequences as well as dynamic contrast- enhanced T1-weighted acquisitions.Results. Three patients with a short disease history showed anterior and/or posterior subperiosteal infiltrations (''lava cleft phenomenon''), transcapsular infiltrations of juxta-articular muscle layers, which obscured the fasciae, and periarticular bone marrow edema. The eight patients with more advanced stages of sacroiliitis additionally showed abscess formation, sequestration, and erosion. At follow-up MR examination (n=7) under systemic antibiotic treatment, the morphologic characteristics showed progression (n=1), regression (n=4), unchanged findings (n=1), or a mixed response (n=1). Clinical improvement precedes resolution of the MR findings.Conclusions. Anterior and/or posterior subperiosteal infiltrations and transcapsular infiltrations of juxta-articular muscle layers were depicted in all patients. These MR imaging findings are characteristic of septic sacroiliitis and may be used to differentiate this entity from sacroiliitis in SpA. (orig.)

  1. Mergers and Acquisitions (M&AS by R&D Intensive Firms

    Directory of Open Access Journals (Sweden)

    Shantanu Dutta

    2009-12-01

    Full Text Available In this study, we evaluate the impact of R&D intensity on acquiring firms’ abnormal returns by examining 925 Canadian completed deals between 1993 and 2002 that have information on R&D expenditures. While examining the returns to acquiring firm shareholders in the R&D intensive firms we evaluate two competing hypotheses: ‘growth potential hypothesis’ and ‘integration failure hypothesis’. According to the ‘growth potential hypothesis’, in light of the growth potential of the targets acquired by R&D intensive firms, investors are likely to react positively. ‘Integration failure hypothesis’ focuses on integration difficulties of a target by an R&D intensive firms and suggests that investor might be skeptical of such acquisitions and react negatively. Our results show that R&D intensity (i.e. R&D expenditure by sales has a positive and significant effect on cumulative abnormal returns of the acquiring firms around the announcement dates. This implies that market generally favors the M&A deals by R&D intensive firms. An analysis of the differentiating characteristics reveal that R&D firms have a significantly higher growth potential and undertake more stock financed deals compared to the non R&D firms. Further, our results show that there is no significant change in long-term operating performance subsequent to the M&A deals for both R&D firms and non R&D firms. In general, our results show support for ‘growth potential hypothesis’.

  2. Hyperthermia system working in combination with an MR imaging unit

    International Nuclear Information System (INIS)

    LeBihan, D.J.; Delannoy, J.; Levin, R.L.; Hoult, D.I.

    1988-01-01

    The authors propose a hyperthermia device to be used for temperature monitoring. It consists of a modified miniannular phased array (MAPA) radio-frequency applicator designed for limb tumor treatment that works in combination with a whole-body MR imaging unit operating at 21 MHz. Highly accurate (0.5 0 c/0.8 cm 2 ) temperature images are obtained noninvasively throughout the heated volume from MR images of molecular diffusion, the relation of which with temperature is well known. The MAPA, electrically modified to be compatible with MR imagers, can be centered inside the MR head coil. The combined system was tested on a phantom in which the temperature distribution was confirmed by miniature thermocouples

  3. SU-F-I-58: Image Quality Comparisons of Different Motion Magnitudes and TR Values in MR-PET

    International Nuclear Information System (INIS)

    Patrick, J; Thompson, R; Tavallaei, M; Drangova, M; Stodilka, R; Gaede, S

    2016-01-01

    Purpose: The aim of this work is to evaluate the accuracy and sensitivity of a respiratory-triggered MR-PET protocol in detecting four different sized lesions at two different magnitudes of motion, with two different TR values, using a novel PET-MR-CT compatible respiratory motion phantom. Methods: The eight-compartment torso phantom was setup adjacent to the motion stage, which moved four spherical compartments (28, 22, 17, 10 mm diameter) in two separate (1 and 2 cm) linear motion profiles, simulating a 3.5 second respiratory cycle. Scans were acquired on a 3T MR-PET system (Biograph mMR; Siemens Medical Solutions, Germany). MR measurements were taken with: 1) Respiratory-triggered T2-weighted turbo spin echo (BLADE) sequence in coronal orientation, and 2) Real-time balanced steady-state gradient echo sequence (TrueFISP) in coronal and sagittal planes. PET was acquired simultaneously with MR. Sphere geometries and motion profiles were measured and compared with ground truths for T2 BLADE-TSE acquisitions and real time TrueFISP images. PET quantification and geometry measurements were taken using standardized uptake values, voxel intensity plots and were compared with known values, and examined alongside MR-based attenuation maps. Contrast and signal-to-noise ratios were also compared for each of the acquisitions as functions of motion range and TR. Results: Comparison of lesion diameters indicate the respiratory triggered T2 BLADE-TSE was able to maintain geometry within −2 mm for 1 cm motion for both TR values, and within −3.1 mm for TR = 2000 ms at 2 cm motion. Sphere measurements in respiratory triggered PET images were accurate within +/− 5 mm for both ranges of motion for 28, 22, and 17 mm diameter spheres. Conclusion: Hybrid MR-PET systems show promise in imaging lung cancer in non-compliant patients, with their ability to acquire both modalities simultaneously. However, MR-based attenuation maps are still susceptible to motion derived artifacts and

  4. SU-F-I-58: Image Quality Comparisons of Different Motion Magnitudes and TR Values in MR-PET

    Energy Technology Data Exchange (ETDEWEB)

    Patrick, J; Thompson, R [Lawson Health Research Institute, London, Ontario (Canada); Tavallaei, M; Drangova, M [Robarts Research Institute, London, Canada, London, Ontario (Canada); Stodilka, R [Western University, Canada, London, Ontario (Canada); Gaede, S [London Regional Cancer Program, London, Ontario (Canada)

    2016-06-15

    Purpose: The aim of this work is to evaluate the accuracy and sensitivity of a respiratory-triggered MR-PET protocol in detecting four different sized lesions at two different magnitudes of motion, with two different TR values, using a novel PET-MR-CT compatible respiratory motion phantom. Methods: The eight-compartment torso phantom was setup adjacent to the motion stage, which moved four spherical compartments (28, 22, 17, 10 mm diameter) in two separate (1 and 2 cm) linear motion profiles, simulating a 3.5 second respiratory cycle. Scans were acquired on a 3T MR-PET system (Biograph mMR; Siemens Medical Solutions, Germany). MR measurements were taken with: 1) Respiratory-triggered T2-weighted turbo spin echo (BLADE) sequence in coronal orientation, and 2) Real-time balanced steady-state gradient echo sequence (TrueFISP) in coronal and sagittal planes. PET was acquired simultaneously with MR. Sphere geometries and motion profiles were measured and compared with ground truths for T2 BLADE-TSE acquisitions and real time TrueFISP images. PET quantification and geometry measurements were taken using standardized uptake values, voxel intensity plots and were compared with known values, and examined alongside MR-based attenuation maps. Contrast and signal-to-noise ratios were also compared for each of the acquisitions as functions of motion range and TR. Results: Comparison of lesion diameters indicate the respiratory triggered T2 BLADE-TSE was able to maintain geometry within −2 mm for 1 cm motion for both TR values, and within −3.1 mm for TR = 2000 ms at 2 cm motion. Sphere measurements in respiratory triggered PET images were accurate within +/− 5 mm for both ranges of motion for 28, 22, and 17 mm diameter spheres. Conclusion: Hybrid MR-PET systems show promise in imaging lung cancer in non-compliant patients, with their ability to acquire both modalities simultaneously. However, MR-based attenuation maps are still susceptible to motion derived artifacts and

  5. Value of new MR techniques in MR-PET

    International Nuclear Information System (INIS)

    Attenberger, U.I.; Schoenberg, S.O.; Quick, H.H.; Guimaraes, A.; Catalano, O.; Morelli, J.N.

    2013-01-01

    The unparalleled soft tissue contrast of magnetic resonance imaging (MRI) and the functional information obtainable with 18-F fluorodeoxyglucose positron emission tomography (FDG-PET) render MR-PET well-suited for oncological and psychiatric imaging. The lack of ionizing radiation with MRI also makes MR-PET a promising modality for oncology patients requiring frequent follow-up and pediatric patients. Lessons learned with PET computed tomography (CT) over the last few years do not directly translate to MR-PET. For example, in PET-CT the Hounsfield units derived from CT are used for attenuation correction (AC). As 511 keV photons emitted in PET examinations are attenuated by the patient's body CT data are converted directly to linear attenuation coefficients (LAC); however, proton density measured by MRI is not directly related to the radiodensity or LACs of biological tissue. Thus, direct conversion to LAC data is not possible making AC more challenging in simultaneous MRI-PET scanning. In addition to these constraints simultaneous MRI-PET acquisitions also improve on some solutions to well-known challenges of hybrid imaging techniques, such as limitations in motion correction. This article reports on initial clinical experiences with simultaneously acquired MRI-PET data, focusing on the potential benefits and limitations of MRI with respect to motion correction as well as metal and attenuation correction artefacts. (orig.) [de

  6. Chemical, laboratory analyses, physical and profile oceanographic data collected aboard the BUNNY BORDELON in the Gulf of Mexico from 2010-08-18 to 2010-08-23 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069118)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, laboratory analyses, physical and profile oceanographic data were collected aboard the BUNNY BORDELON in the Gulf of Mexico from 2010-08-18 to 2010-08-23...

  7. Anterior chamber configuration in patients with glaucoma: MR gonioscopy evaluation with half-Fourier single-shot RARE sequence and microscopy coil.

    Science.gov (United States)

    Tanitame, Keizo; Sasaki, Ko; Sone, Takashi; Uyama, Shinji; Sumida, Masumi; Ichiki, Toshio; Ito, Katsuhide

    2008-10-01

    The purpose of the study was to determine the accuracy of half-Fourier single-shot rapid acquisition with relaxation enhancement high-spatial-resolution magnetic resonance (MR) imaging performed with a microscopy coil in the diagnosis of narrow anterior chamber angle in patients with glaucoma. Slit-lamp biomicroscopy served as the reference standard. The institutional review board approved this study, and written informed consent was obtained from the 20 recruited patients. There was excellent agreement between MR gonioscopy and slit-lamp biomicroscopy in the classification of anterior chamber angles as narrow or open (kappa = 0.89 [95% confidence interval: 0.69, 1.10]). MR gonioscopy has substantial potential as a technique used to evaluate glaucoma. (c) RSNA, 2008.

  8. 77 FR 12796 - Commerce Business Apps Challenge

    Science.gov (United States)

    2012-03-02

    ... and members of their immediate family (spouses, children, siblings, parents), and persons living in... SUCH LOSS, HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, ARISING OUT OF OR IN CONNECTION WITH THE.... 15. 508 Compliance: Participants should keep in mind that the Department of Commerce considers...

  9. Unified cosmic history in modified gravity: From F(R) theory to Lorentz non-invariant models

    Science.gov (United States)

    Nojiri, Shin'Ichi; Odintsov, Sergei D.

    2011-08-01

    The classical generalization of general relativity is considered as the gravitational alternative for a unified description of the early-time inflation with late-time cosmic acceleration. The structure and cosmological properties of a number of modified theories, including traditional F(R) and Hořava-Lifshitz F(R) gravity, scalar-tensor theory, string-inspired and Gauss-Bonnet theory, non-local gravity, non-minimally coupled models, and power-counting renormalizable covariant gravity are discussed. Different representations of and relations between such theories are investigated. It is shown that some versions of the above theories may be consistent with local tests and may provide a qualitatively reasonable unified description of inflation with the dark energy epoch. The cosmological reconstruction of different modified gravities is provided in great detail. It is demonstrated that eventually any given universe evolution may be reconstructed for the theories under consideration, and the explicit reconstruction is applied to an accelerating spatially flat Friedmann-Robertson-Walker (FRW) universe. Special attention is paid to Lagrange multiplier constrained and conventional F(R) gravities, for latter F(R) theory, the effective ΛCDM era and phantom divide crossing acceleration are obtained. The occurrences of the Big Rip and other finite-time future singularities in modified gravity are reviewed along with their solutions via the addition of higher-derivative gravitational invariants.

  10. 76 FR 66043 - Membership of the National Telecommunications and Information Administration's Performance Review...

    Science.gov (United States)

    2011-10-25

    ... Human Resources Operations Center (DOCHROC), Office of Staffing, Recruitment, and Classification..., Career SES. Karl B. Nebbia, Associate Administrator for Spectrum Management, Career SES. Alan W. Vincent... Commerce Human Resources Operations Center. [FR Doc. 2011-27486 Filed 10-24-11; 8:45 am] BILLING CODE 3510...

  11. Gravitational radiation in quadratic f(R) gravity

    International Nuclear Information System (INIS)

    Naef, Joachim; Jetzer, Philippe

    2011-01-01

    We investigate the gravitational radiation emitted by an isolated system for gravity theories with Lagrange density f(R)=R+aR 2 . As a formal result, we obtain leading order corrections to the quadrupole formula in general relativity. We make use of the analogy of f(R) theories with scalar-tensor theories, which in contrast to general relativity feature an additional scalar degree of freedom. Unlike general relativity, where the leading order gravitational radiation is produced by quadrupole moments, the additional degree of freedom predicts gravitational radiation of all multipoles, in particular, monopoles and dipoles, as this is the case for the most alternative gravity theories known today. An application to a hypothetical binary pulsar moving in a circular orbit yields the rough limit a 17 m 2 by constraining the dipole power to account at most for 1% of the quadrupole power as predicted by general relativity.

  12. Relationship of signal-to-noise ratio with acquisition parameters in MRI for a given contrast

    International Nuclear Information System (INIS)

    Bittoun, J.; Leroy-Willig, A.; Idy, I.; Halimi, P.; Syrota, A.; Desgrez, A.; Saint-Jalmes, H.

    1987-01-01

    The signal-to-noise ratio (SNR) is certainly the most important characteristic of medical images, since the spatial resolution and the visualization of contrast are dependent on its value. On the other hand, modifying an acquisition variable in magnetic resonance imaging, in order to improve spatial resolution for example, may induce a SNR loss and finally alter the image quality. We have studied a theoretical relation between SNR and 2DFT method acquisition variables with the exception of parameters such as TR, TE and TI; these parameters are determined by the desired contrast in order to confirm a diagnosis. According to this relation SNR is proportional to each dimension of the slice, and to the square root of the number of averaged signals; it is inversely proportional to the number of frequency points and to the square root of the number of phase points. This relation was experimentally verified with phantoms and on an MR system at 1.5 T. It was then plotted as a multiple-entry graph on which operators at the console can read the number of averaged signals necessary to compensate SNR loss induced by a modification of other parameters [fr

  13. Solar system and equivalence principle constraints on f(R) gravity by the chameleon approach

    International Nuclear Information System (INIS)

    Capozziello, Salvatore; Tsujikawa, Shinji

    2008-01-01

    We study constraints on f(R) dark energy models from solar system experiments combined with experiments on the violation of the equivalence principle. When the mass of an equivalent scalar field degree of freedom is heavy in a region with high density, a spherically symmetric body has a thin shell so that an effective coupling of the fifth force is suppressed through a chameleon mechanism. We place experimental bounds on the cosmologically viable models recently proposed in the literature that have an asymptotic form f(R)=R-λR c [1-(R c /R) 2n ] in the regime R>>R c . From the solar system constraints on the post-Newtonian parameter γ, we derive the bound n>0.5, whereas the constraints from the violations of the weak and strong equivalence principles give the bound n>0.9. This allows a possibility to find the deviation from the Λ-cold dark matter (ΛCDM) cosmological model. For the model f(R)=R-λR c (R/R c ) p with 0 -10 , which shows that this model is hardly distinguishable from the ΛCDM cosmology

  14. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the OCEAN VERITAS in the Gulf of Mexico from 2010-08-18 to 2010-08-22 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069105)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the OCEAN VERITAS in the Gulf of Mexico from 2010-08-18 to 2010-08-22 in...

  15. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the OCEAN VERITAS in the Gulf of Mexico from 2010-08-25 to 2010-08-29 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069106)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the OCEAN VERITAS in the Gulf of Mexico from 2010-08-25 to 2010-08-29 in...

  16. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the OCEAN VERITAS in the Gulf of Mexico from 2010-08-12 to 2010-08-16 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069104)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the OCEAN VERITAS in the Gulf of Mexico from 2010-08-12 to 2010-08-16 in...

  17. Chemical, laboratory analyses, physical and profile oceanographic data collected aboard the JACK FITZ in the Gulf of Mexico from 2010-08-18 to 2010-08-23 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069119)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, laboratory analyses, physical and profile oceanographic data were collected aboard the JACK FITZ in the Gulf of Mexico from 2010-08-18 to 2010-08-23 in...

  18. Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR

    Energy Technology Data Exchange (ETDEWEB)

    Maffei, Erica; Seitun, Sara [Giovanni XXIII Hospital, Cardiovascular Radiology Unit, Monastier di Treviso (Italy); Messalli, Giancarlo; Catalano, Onofrio [SDN Foundation - IRCCS, Naples (Italy); Martini, Chiara; Cademartiri, Filippo [Giovanni XXIII Hospital, Cardiovascular Radiology Unit, Monastier di Treviso (Italy); Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Nieman, Koen; Rossi, Alexia; Mollet, Nico R. [Erasmus Medical Center, Department of Radiology and Cardiology, Rotterdam (Netherlands); Guaricci, Andrea I. [Azienda Ospedaliero-Universitaria di Foggia, Department of Cardiology, Foggia (Italy); Tedeschi, Carlo [Ospedale San Gennaro, Department of Cardiology, Naples (Italy)

    2012-05-15

    To compare Magnetic Resonance (MR) and Computed Tomography (CT) for the assessment of left (LV) and right (RV) ventricular functional parameters. Seventy nine patients underwent both Cardiac CT and Cardiac MR. Images were acquired using short axis (SAX) reconstructions for CT and 2D cine b-SSFP (balanced-steady state free precession) SAX sequence for MR, and evaluated using dedicated software. CT and MR images showed good agreement: LV EF (Ejection Fraction) (52 {+-} 14% for CT vs. 52 {+-} 14% for MR; r = 0.73; p > 0.05); RV EF (47 {+-} 12% for CT vs. 47 {+-} 12% for MR; r = 0.74; p > 0.05); LV EDV (End Diastolic Volume) (74 {+-} 21 ml/m{sup 2} for CT vs. 76 {+-} 25 ml/m{sup 2} for MR; r = 0.59; p > 0.05); RV EDV (84 {+-} 25 ml/m{sup 2} for CT vs. 80 {+-} 23 ml/m{sup 2} for MR; r = 0.58; p > 0.05); LV ESV (End Systolic Volume)(37 {+-} 19 ml/m{sup 2} for CT vs. 38 {+-} 23 ml/m{sup 2} for MR; r = 0.76; p > 0.05); RV ESV (46 {+-} 21 ml/m{sup 2} for CT vs. 43 {+-} 18 ml/m{sup 2} for MR; r = 0.70; p > 0.05). Intra- and inter-observer variability were good, and the performance of CT was maintained for different EF subgroups. Cardiac CT provides accurate and reproducible LV and RV volume parameters compared with MR, and can be considered as a reliable alternative for patients who are not suitable to undergo MR. circle Cardiac-CT is able to provide Left and Right Ventricular function. circle Cardiac-CT is accurate as MR for LV and RV volume assessment. (orig.)

  19. Generation of brain pseudo-CTs using an undersampled, single-acquisition UTE-mDixon pulse sequence and unsupervised clustering

    International Nuclear Information System (INIS)

    Su, Kuan-Hao; Hu, Lingzhi; Traughber, Melanie; Stehning, Christian; Helle, Michael; Qian, Pengjiang; Thompson, Cheryl L.; Pereira, Gisele C.; Traughber, Bryan J.; Jordan, David W.; Herrmann, Karin A.; Muzic, Raymond F.

    2015-01-01

    Purpose: MR-based pseudo-CT has an important role in MR-based radiation therapy planning and PET attenuation correction. The purpose of this study is to establish a clinically feasible approach, including image acquisition, correction, and CT formation, for pseudo-CT generation of the brain using a single-acquisition, undersampled ultrashort echo time (UTE)-mDixon pulse sequence. Methods: Nine patients were recruited for this study. For each patient, a 190-s, undersampled, single acquisition UTE-mDixon sequence of the brain was acquired (TE = 0.1, 1.5, and 2.8 ms). A novel method of retrospective trajectory correction of the free induction decay (FID) signal was performed based on point-spread functions of three external MR markers. Two-point Dixon images were reconstructed using the first and second echo data (TE = 1.5 and 2.8 ms). R2 ∗ images (1/T2 ∗ ) were then estimated and were used to provide bone information. Three image features, i.e., Dixon-fat, Dixon-water, and R2 ∗ , were used for unsupervised clustering. Five tissue clusters, i.e., air, brain, fat, fluid, and bone, were estimated using the fuzzy c-means (FCM) algorithm. A two-step, automatic tissue-assignment approach was proposed and designed according to the prior information of the given feature space. Pseudo-CTs were generated by a voxelwise linear combination of the membership functions of the FCM. A low-dose CT was acquired for each patient and was used as the gold standard for comparison. Results: The contrast and sharpness of the FID images were improved after trajectory correction was applied. The mean of the estimated trajectory delay was 0.774 μs (max: 1.350 μs; min: 0.180 μs). The FCM-estimated centroids of different tissue types showed a distinguishable pattern for different tissues, and significant differences were found between the centroid locations of different tissue types. Pseudo-CT can provide additional skull detail and has low bias and absolute error of estimated CT

  20. Brain imaging with synthetic MR in children: clinical quality assessment

    Energy Technology Data Exchange (ETDEWEB)

    Betts, Aaron M.; Serai, Suraj [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Leach, James L.; Jones, Blaise V. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); University of Cincinnati College of Medicine, Cincinnati, OH (United States); Zhang, Bin [Cincinnati Children' s Hospital Medical Center, Biostatistics and Epidemiology, Cincinnati, OH (United States)

    2016-10-15

    Synthetic magnetic resonance imaging is a quantitative imaging technique that measures inherent T1-relaxation, T2-relaxation, and proton density. These inherent tissue properties allow synthesis of various imaging sequences from a single acquisition. Clinical use of synthetic MR imaging has been described in adult populations. However, use of synthetic MR imaging has not been previously reported in children. The purpose of this study is to report our assessment of diagnostic image quality using synthetic MR imaging in children. Synthetic MR acquisition was obtained in a sample of children undergoing brain MR imaging. Image quality assessments were performed on conventional and synthetic T1-weighted, T2-weighted, and FLAIR images. Standardized linear measurements were performed on conventional and synthetic T2 images. Estimates of patient age based upon myelination patterns were also performed. Conventional and synthetic MR images were evaluated on 30 children. Using a 4-point assessment scale, conventional imaging performed better than synthetic imaging for T1-weighted, T2-weighted, and FLAIR images. When the assessment was simplified to a dichotomized scale, the conventional and synthetic T1-weighted and T2-weighted images performed similarly. However, the superiority of conventional FLAIR images persisted in the dichotomized assessment. There were no statistically significant differences between linear measurements made on T2-weighted images. Estimates of patient age based upon pattern of myelination were also similar between conventional and synthetic techniques. Synthetic MR imaging may be acceptable for clinical use in children. However, users should be aware of current limitations that could impact clinical utility in the software version used in this study. (orig.)

  1. Main Issues on Electronic Commerce and Policy Recommendations

    OpenAIRE

    Chongwha Lee; Seongbong Lee

    1998-01-01

    "Electronic Commerce" means that people sell and buy commodity, labor service and information through internet and now is mainly be used in commercial intercourse. The core of the international research related to Electronic Commerce is a tax-exemption, land tax, liberalization of encrypted technology and privacy protection policy, etc. Meanwhile, intellectual property, consumer protection and limitation of packing specification are also researched together with the business activeness. The r...

  2. 76 FR 21660 - Changes in Flood Elevation Determinations

    Science.gov (United States)

    2011-04-18

    ... respective addresses are listed in the table below. FOR FURTHER INFORMATION CONTACT: Luis Rodriguez, Chief...: Adams City of Commerce City February 1, 2011; The Honorable Paul June 8, 2011 080006 (10-08-0226P...

  3. 44 CFR 351.28 - The Department of Commerce.

    Science.gov (United States)

    2010-10-01

    ... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false The Department of Commerce. 351.28 Section 351.28 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY... Assignments § 351.28 The Department of Commerce. (a) Assist State and local governments in determining their...

  4. 49 CFR 387.321 - Operations in foreign commerce.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Operations in foreign commerce. 387.321 Section 387.321 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER... Carriers and Property Brokers § 387.321 Operations in foreign commerce. No motor carrier may operate in the...

  5. INT WFC photometry of a Galactic flare star spatially coincident with the recurrent nova candidate M31N 1966-08a = 1968-10c

    Science.gov (United States)

    Arce-Tord, C.; Esteban-Gutierrez, A.; Garcia-Broock, E.; Garcia-Rivas, M.; Gonzalez-Cuesta, L.; Hermosa-Muñoz, L.; Hernandez-Sanchez, M.; Jimenez-Gallardo, A.; Lopez-Navas, E.; Mantero-Castañeda, E. A.; Otero-Santos, J.; Prendin, M. G.; Rodriguez-Sanchez, M.; Perez-Fournon, I.

    2017-12-01

    We report photometry in the Sloan g (3x150s), r (3x100s), and i (3x100s) bands of the recurrent nova candidate M31N 1966-08a = 1968-10c (= PNV J00412371+4114594) from observations with the Wide Field Camera of the Isaac Newton Telescope* on the night of 28 October 2017.

  6. Turbidity, SOLAR RADIATION - ATMOSPHERIC and other data from SURVEYOR in the North Pacific Ocean, Bering Sea and NE Pacific from 1995-09-10 to 1995-09-19 (NODC Accession 9600139)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Hydrophysical, hydrochemical, and other data were collected from the SURVEYOR from September 10, 1995 to September 19, 1995. Data were submitted by Mr. David Kachel...

  7. Nonsuppressing normal thymus on chemical-shift MR imaging and anterior mediastinal lymphoma. Differentiation with diffusion-weighted MR imaging by using the apparent diffusion coefficient

    International Nuclear Information System (INIS)

    Priola, Adriano Massimiliano; Priola, Sandro Massimo; Gned, Dario; Veltri, Andrea; Giraudo, Maria Teresa

    2018-01-01

    To prospectively evaluate usefulness of the apparent diffusion coefficient (ADC) in differentiating anterior mediastinal lymphoma from nonsuppressing normal thymus on chemical-shift MR, and to look at the relationship between patient age and ADC. Seventy-three young subjects (25 men, 48 women; age range, 9-29 years), who underwent chemical-shift MR and diffusion-weighted MR were divided into a normal thymus group (group A, 40 subjects), and a lymphoma group (group B, 33 patients). For group A, all subjects had normal thymus with no suppression on opposed-phase chemical-shift MR. Two readers measured the signal intensity index (SII) and ADC. Differences in SII and ADC between groups were tested using t-test. ADC was correlated with age using Pearson correlation coefficient. Mean SII±standard deviation was 2.7±1.8% for group A and 2.2±2.4% for group B, with no significant difference between groups (P=.270). Mean ADC was 2.48±0.38 x 10 -3 mm 2 /s for group A and 1.24±0.23 x 10 -3 mm 2 /s for group B. A significant difference between groups was found (P<.001), with no overlap in range. Lastly, significant correlation was found between age and ADC (r=0.935, P<.001) in group A. ADC of diffusion-weighted MR is a noninvasive and accurate parameter for differentiating lymphoma from nonsuppressing thymus on chemical-shift MR in young subjects. (orig.)

  8. Development of a data acquisition unit intended for pulsed plasma measurements

    International Nuclear Information System (INIS)

    Moulin, B.

    1976-12-01

    A system suitable for the acquisition of the signals from measuring devices implanted in Petula and Wega is described. The technical specifications of the data acquisition system are discussed together with the results obtained [fr

  9. Rate Processes in Dissipative Systems: 50 Years After Kramers, Discussion Meeting Held in Tutzing (Germany, F.R.) on 10-13 September 1990

    Science.gov (United States)

    1990-09-13

    Chem. Soc., Faraday Trans. [5] S. T. Abdel-Halim, M. H. Abdel-Kader, and U. E. Steiner , J. 2, 83, 1941 (1987), Phys. Chem 92, 4324 (1988). [29] W...December 5th, 1990) Zusammensetzung, Eigenschaften und Anwendungen Mesomorpher Tensidphasen RUDOLF HEUSCH Leverkusen, Paul-Klee-StraBe 85 (Received on...Institut f~r Anorganisehe Chemnie der Universitiit Rudower Chaussee 5, 0-1199 Physikalisehe Chemie) Rudolf - Bern, Freie Stra~e 3, CH-3000 Bern, be- Berlin

  10. Matas test combined with MR flow measurement

    International Nuclear Information System (INIS)

    Isoda, Haruo; Masui, Takayuki; Takahashi, Motoichiro; Mochizuki, Takao; Kaneko, Masao; Ohta, Atsuko; Shirakawa, Toyomi.

    1993-01-01

    Prior to the temporary or permanent therapeutic occlusion of the carotid artery, evaluation of the cerebral collateral circulation via the circle of Willis is necessary in order to prevent complications. The purpose of our study was to evaluate the flow velocity of the contralateral common carotid artery using Renal Time Acquisition and Velocity Evaluation (RACE) before and during a Matas test and to estimate brain collateral circulation. Five normal subjects were studied with a 1.5 T superconducting imager (Siemens, Erlangen) using a neck coil. RACE is a one-dimensional projective flow measurement technique using fast low angle shot (FLASH) without phase encoding gradient (FLASH sequence: TR=20 ms, TE=6 ms, FA=90 degrees, FOV=220 mm, slice thickness=8 mm). The total acquisition time is about 10 seconds without need for electrocardiographic synchronization. Flow velocity of the common carotid artery was evaluated using the RACE technique before and during a Matas test. The relative flow ratio of the contralateral carotid artery (flow velocity during the Matas test divided by that before the Matas test) was calculated. Additionally, using a head coil, 3 dimensional time-flight MR angiograms of the brain were obtained for each subject order to evaluate the anterior communicating artery. Six out of the 10 common carotid arteries were sufficiently compressed to stop blood flow. The relative mean ratio was 1.74 with a standard deviation of 0.36. The anterior communicating artery was visualized in all subjects. Increased blood volume is thus thought to maintain the blood supply of a cerebral hemisphere affected by compression of the common carotid artery via the anterior communicating artery. MR flow measurement using RACE before and during the Matas test seems to be a noninvasive method for evaluating cerebral collateral circulation via the circle of Willis. (author)

  11. Kalman filtered MR temperature imaging for laser induced thermal therapies.

    Science.gov (United States)

    Fuentes, D; Yung, J; Hazle, J D; Weinberg, J S; Stafford, R J

    2012-04-01

    The feasibility of using a stochastic form of Pennes bioheat model within a 3-D finite element based Kalman filter (KF) algorithm is critically evaluated for the ability to provide temperature field estimates in the event of magnetic resonance temperature imaging (MRTI) data loss during laser induced thermal therapy (LITT). The ability to recover missing MRTI data was analyzed by systematically removing spatiotemporal information from a clinical MR-guided LITT procedure in human brain and comparing predictions in these regions to the original measurements. Performance was quantitatively evaluated in terms of a dimensionless L(2) (RMS) norm of the temperature error weighted by acquisition uncertainty. During periods of no data corruption, observed error histories demonstrate that the Kalman algorithm does not alter the high quality temperature measurement provided by MR thermal imaging. The KF-MRTI implementation considered is seen to predict the bioheat transfer with RMS error 10 sec.

  12. Chemical, physical and profile oceanographic data collected aboard NOAA Ship HENRY B. BIGELOW in the Gulf of Mexico from 2010-08-13 to 2010-08-22 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0068954)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical and profile oceanographic data were collected aboard NOAA Ship HENRY B. BIGELOW in the Gulf of Mexico from 2010-08-13 to 2010-08-22 in response to...

  13. Delayed XBT data collected by Commonwealth Scientific Industrial Research Organization (CSIRO) for the Global Temperature-Salinity Profile Program (GTSPP), dates range from 01-05-1993 to 10-08-1993 (NODC Accession 0041369)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — XBT and CTD data were collected in the Indian Ocean aboard the Aurora Australis from 05 January 1993 to 08 October 1993. Data were submitted by the CommonWealth...

  14. E-commerce and Business Case of a US E-commerce firm

    OpenAIRE

    Pereira Sanchez, Sergio

    2010-01-01

    What do we know as E-commerce and E-Business? Unique features of E-commerce. Types of E-commerce. History and feature of E-commerce. Why does E-commerce develop better in some places than in others? What make a current E-commerce success? Introduction of the US E-commerce firm studied. Bussiness case (customer, product, company and competition). Conclusions.

  15. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the Brooks McCall in the Gulf of Mexico from 2010-08-03 to 2010-08-07 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069055)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the Brooks McCall in the Gulf of Mexico from 2010-08-03 to 2010-08-07 in...

  16. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the Brooks McCall in the Gulf of Mexico from 2010-08-21 to 2010-08-25 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069090)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the Brooks McCall in the Gulf of Mexico from 2010-08-21 to 2010-08-25 in...

  17. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the Brooks McCall in the Gulf of Mexico from 2010-08-15 to 2010-08-19 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069057)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the Brooks McCall in the Gulf of Mexico from 2010-08-15 to 2010-08-19 in...

  18. Chemical, physical, profile and laboratory analysis oceanographic data collected aboard the Brooks McCall in the Gulf of Mexico from 2010-08-09 to 2010-08-12 in response to the Deepwater Horizon Oil Spill event (NODC Accession 0069056)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical, physical, profile and laboratory analysis oceanographic data were collected aboard the Brooks McCall in the Gulf of Mexico from 2010-08-09 to 2010-08-12 in...

  19. Chemical and physical oceanographic profile data collected from CTD casts aboard the Wes Bordelon in the Gulf of Mexico from 2010-08-18 to 2010-08-22 in response to the Deepwater Horizon oil spill event (NODC Accession 0069086)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical and physical oceanographic profile data were collected aboard the Wes Bordelon in the Gulf of Mexico from 2010-08-18 to 2010-08-22 in response to the...

  20. e-Commerce versus m-Commerce: Where is the Dividing Line?

    OpenAIRE

    Priscilla Omonedo; Paul Bocij

    2014-01-01

    Since the emergence of e-Commerce, the world of business has witnessed a radical shift in the way business activities are conducted. However, the emergence of m-Commerce has further pushed the boundaries of virtual commerce revolution. As a result, there seems to be a growing blur in the distinction between e- Commerce and m-Commerce. In addition, existing definitions for both forms of commerce highlight characteristics (e.g. type of device and activity conducted) that ma...

  1. E-Commerce and Mobile Commerce in South Africa: Regulatory Challenges

    OpenAIRE

    JOBODWANA, Z NTOZINTLE

    2009-01-01

    E-commerce refers to all forms of commercial transactions that involve individuals and organizations based on the electronic processing of data. Mobile commerce (M-commerce) is the buying and selling of goods and services using mobile telephones or personal digital assistants (PDA). M-commerce is emerging in Africa and South Africa especially as either a complement or an alternative to e-commerce as originally conceived, though there are arguments that mobile telephone technology “m-commerc...

  2. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    Science.gov (United States)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  3. Developing Customer Trust in E-Commerce Using Inbound Marketing Strategies

    Directory of Open Access Journals (Sweden)

    Adrian MICU

    2017-06-01

    Full Text Available Developing a new argument that digital content is a factor for inbound marketing campaigns is redundant, considering there are numerous papers in the relevant literature. The aim of this paper is to use FsQCA to demonstrate the direct implications of quality content as a trust factor on the acquisition of search engine traffic. Concluding on strategies to build customer confidence in e-commerce, based on educative and representative content on a particular niche. In this research, we've analyzed 18 causal conditions collected from different online references to reach the outcome. These findings can help marketing managers to develop strategies to attract a relevant audience for e-commerce websites.

  4. Chemical and physical oceanographic profile data collected from CTD casts aboard the HOS Davis in the Gulf of Mexico from 2010-08-13 to 2010-08-22 in response to the Deepwater Horizon oil spill event (NODC Accession 0069069)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical and physical oceanographic profile data were collected aboard the HOS Davis in the Gulf of Mexico from 2010-08-13 to 2010-08-22 in response to the Deepwater...

  5. Subjective Cognitive Decline: Mapping Functional and Structural Brain Changes-A Combined Resting-State Functional and Structural MR Imaging Study.

    Science.gov (United States)

    Sun, Yu; Dai, Zhengjia; Li, Yuxia; Sheng, Can; Li, Hongyan; Wang, Xiaoni; Chen, Xiaodan; He, Yong; Han, Ying

    2016-10-01

    Purpose To determine whether individuals with subjective cognitive decline (SCD) exhibit functional and structural brain alterations by using resting-state functional and structural magnetic resonance (MR) imaging. Materials and Methods This study received institutional review board approval, and all participants gave informed consent. Resting-state functional MR imaging and structural MR imaging techniques were used to measure amplitude of low-frequency fluctuations (ALFF) and regional gray matter volume in 25 subjects with SCD (mean age, 65.52 years ± 6.12) and 61 control subjects (mean age, 64.11 years ± 8.59). Voxel-wise general linear model analyses were used to examine between-group differences in ALFF or in gray matter volume and to further determine the brain-behavioral relationship. Results Subjects with SCD exhibited higher ALFF values than did control subjects in the bilateral inferior parietal lobule (left: 0.44 ± 0.25 vs 0.27 ± 0.18, respectively; P = .0003; right: 1.46 ± 0.45 vs 1.10 ± 0.37, respectively; P = .0015), right inferior (0.45 ± 0.15 vs 0.37 ± 0.08, repectively; P = .0106) and middle (1.03 ± 0.32 vs 0.83 ± 0.20, respectively; P = .0008) occipital gyrus, right superior temporal gyrus (0.11 ± 0.07 vs 0.07 ± 0.04, respectively; P = .0016), and right cerebellum posterior lobe (0.51 ± 0.27 vs 0.39 ± 0.15, respectively; P = .0010). In the SCD group, significant correlations were found between Auditory Verbal Learning Test recognition scores and ALFF in the left inferior parietal lobe (r = -0.79, P Learning Test immediate recall scores and ALFF values in the right middle occipital gyrus (r = -0.64, P = .002). Nonsignificant group differences were found in gray matter volume (P > .05, corrected). Conclusion Individuals with SCD had altered spontaneous functional activity, suggesting that resting-state functional MR imaging may be a noninvasive method for characterizing SCD. (©) RSNA, 2016 Online supplemental material is available for

  6. 15 CFR 19.7 - When will Commerce entities compromise a Commerce debt?

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false When will Commerce entities compromise a Commerce debt? 19.7 Section 19.7 Commerce and Foreign Trade Office of the Secretary of Commerce COMMERCE DEBT COLLECTION Procedures To Collect Commerce Debts § 19.7 When will Commerce entities compromise...

  7. 76 FR 13353 - Department of Commerce FY 2011-2016 Strategic Plan

    Science.gov (United States)

    2011-03-11

    ... performance measures (i.e., GPRA measures) for tracking attainment. The Department's Strategic Plan is...-2016 Strategic Plan AGENCY: Department of Commerce. ACTION: Request for comment. SUMMARY: The Department of Commerce (Department) is updating its current FY 2007-2012 Strategic Plan. As part of this...

  8. Design and Construction Rules for Mechanical components of FBR nuclear islands: RCC-MR. Tome 1, Volume A: generalities

    International Nuclear Information System (INIS)

    1985-06-01

    The French Rules of Mechanical equipments of Fast Neutron nuclear Reactors (RCC-MR) aims at equipments included in a safety classification. The equipments concerned are those of the nuclear boiler and its auxiliaries: tanks, vessels, internal equipments of the reactor, exchangers, pumps, fittings, pipes, and supports. The present edition of the RCC-MR comprises 12 books presented in the present one in the volume A. The chapter RA 3000 defines the documents to be established in application of the RCC-MR rules. The chapter RA 5000 defines the requirements to take into account to establish and carry out quality Assurance programs according to the RCC-MR rules [fr

  9. Sedation of children for MR or CT imaging examination using chloral hydrate

    International Nuclear Information System (INIS)

    Song, Jong Gi; Kim, Woo Sun; Kim, In One; Yeon, Kyung Mo; Han, Man Chung

    1994-01-01

    Pediatric sedation is an important factor for obtaining the images of good quality. We performed this study to analyze the efficacy of our sedation protocol using chloral hydrate. We collected prospectively 151 sedation records of children(1 day-15 years old), who were sedated with chloral hydrate for MR(n=112) or CT(n=39) studies. We initially administered 50 mg/Kg orally(n=94) or rectally(n=57) 30 minutes before the scheduled examinations, and then administered additional dose (second dose: 25-35 mg/Kg, third dose: 10-15 mg/Kg) to patients whom initial dose failed to sedate. Satisfactory sedation was achieved by initial administration in 109 patients(72%) without significant difference between oral(per oral; P. O.) and rectal(per rectal: P.R.) administration. Second dose was required in 28% and third dose in 5%. MR and CT examinations required second dose in 36(32%) and 6 patients(15%), respectively. P.O. -patients vomited in 5%. P.R. -patients defecated in 22% after initial administration. There were no other serious complications. Time interval from the drug administration to the start of examinations was 33 minutes in initial-dose-group and 64 minutes in additional-dose-group. Two patients could not complete MR examination due to early arousal. Prolonged sedation, requiring more than 30 minutes for alertness after MR and CT examinations, was encountered in twenty(18%) and two patients(5%) respectively. Our protocol using chloral hydrate(P.O. or P.R.) is thought to be an effective and safe method for pediatric sedation for MR or CT imaging

  10. Evaluation of a multiple spin- and gradient-echo (SAGE) EPI acquisition with SENSE acceleration: applications for perfusion imaging in and outside the brain.

    Science.gov (United States)

    Skinner, Jack T; Robison, Ryan K; Elder, Christopher P; Newton, Allen T; Damon, Bruce M; Quarles, C Chad

    2014-12-01

    Perfusion-based changes in MR signal intensity can occur in response to the introduction of exogenous contrast agents and endogenous tissue properties (e.g. blood oxygenation). MR measurements aimed at capturing these changes often implement single-shot echo planar imaging (ssEPI). In recent years ssEPI readouts have been combined with parallel imaging (PI) to allow fast dynamic multi-slice imaging as well as the incorporation of multiple echoes. A multiple spin- and gradient-echo (SAGE) EPI acquisition has recently been developed to allow measurement of transverse relaxation rate (R2 and R2(*)) changes in dynamic susceptibility contrast (DSC)-MRI experiments in the brain. With SAGE EPI, the use of PI can influence image quality, temporal resolution, and achievable echo times. The effect of PI on dynamic SAGE measurements, however, has not been evaluated. In this work, a SAGE EPI acquisition utilizing SENSE PI and partial Fourier (PF) acceleration was developed and evaluated. Voxel-wise measures of R2 and R2(*) in healthy brain were compared using SAGE EPI and conventional non-EPI multiple echo acquisitions with varying SENSE and PF acceleration. A conservative SENSE factor of 2 with PF factor of 0.73 was found to provide accurate measures of R2 and R2(*) in white (WM) (rR2=[0.55-0.79], rR2*=[0.47-0.71]) and gray (GM) matter (rR2=[0.26-0.59], rR2*=[0.39-0.74]) across subjects. The combined use of SENSE and PF allowed the first dynamic SAGE EPI measurements in muscle, with a SENSE factor of 3 and PF factor of 0.6 providing reliable relaxation rate estimates when compared to multi-echo methods. Application of the optimized SAGE protocol in DSC-MRI of high-grade glioma patients provided T1 leakage-corrected estimates of CBV and CBF as well as mean vessel diameter (mVD) and simultaneous measures of DCE-MRI parameters K(trans) and ve. Likewise, application of SAGE in a muscle reperfusion model allowed dynamic measures of R2', a parameter that has been shown to correlate

  11. A spiral-based volumetric acquisition for MR temperature imaging.

    Science.gov (United States)

    Fielden, Samuel W; Feng, Xue; Zhao, Li; Miller, G Wilson; Geeslin, Matthew; Dallapiazza, Robert F; Elias, W Jeffrey; Wintermark, Max; Butts Pauly, Kim; Meyer, Craig H

    2018-06-01

    To develop a rapid pulse sequence for volumetric MR thermometry. Simulations were carried out to assess temperature deviation, focal spot distortion/blurring, and focal spot shift across a range of readout durations and maximum temperatures for Cartesian, spiral-out, and retraced spiral-in/out (RIO) trajectories. The RIO trajectory was applied for stack-of-spirals 3D imaging on a real-time imaging platform and preliminary evaluation was carried out compared to a standard 2D sequence in vivo using a swine brain model, comparing maximum and mean temperatures measured between the two methods, as well as the temporal standard deviation measured by the two methods. In simulations, low-bandwidth Cartesian trajectories showed substantial shift of the focal spot, whereas both spiral trajectories showed no shift while maintaining focal spot geometry. In vivo, the 3D sequence achieved real-time 4D monitoring of thermometry, with an update time of 2.9-3.3 s. Spiral imaging, and RIO imaging in particular, is an effective way to speed up volumetric MR thermometry. Magn Reson Med 79:3122-3127, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  12. Event-related potentials elicited by social commerce and electronic-commerce reviews

    OpenAIRE

    Bai, Yan; Yao, Zhong; Cong, Fengyu; Zhang, Linlin

    2015-01-01

    There is an increasing interest regarding the use of electroencephalography (EEG) in social commerce and electronic commerce (e-commerce) research. There are several reviews in the field of social commerce or e-commerce; these have great potential value and mining them is fundamental and significant. To our knowledge, EEG is rarely applied to study these. In this study, we examined the neural correlates of social commerce reviews (SCRs) and e-commerce reviews (ECRs) by using them as stimuli t...

  13. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Haller, Joerg [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Ludwig Boltzmann Institute for Osteology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Bernt, Reinhard [Department of Radiology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria)]. E-mail: reinhard.bernt@wgkk.sozvers.at; Seeger, Thomas [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Weissenbaeck, Alexander [Department of Trauma Surgery, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Tuechler, Heinrich [Ludwig Boltzmann Institute for Hematology, Hanusch Hospital, Heinrich Collin-Strasse 30, A-1140 Vienna (Austria); Resnick, Donald [Department of Radiology, VA Medical Center, UCSD, 3350 La Jolla Village Dr, San Diego, CA 92161 (United States)

    2006-06-15

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome.

  14. MR-imaging of anterior tibiotalar impingement syndrome: Agreement, sensitivity and specificity of MR-imaging and indirect MR-arthrography

    International Nuclear Information System (INIS)

    Haller, Joerg; Bernt, Reinhard; Seeger, Thomas; Weissenbaeck, Alexander; Tuechler, Heinrich; Resnick, Donald

    2006-01-01

    Objective: To clarify the role of MR-imaging in the diagnosis of anterior ankle impingement syndromes. Materials and methods: We prospectively examined 51 consecutive patients with chronic ankle pain by MR-imaging. Arthroscopy was performed in 29 patients who previously underwent non-enhanced MR-imaging; in 11 patients, indirect MR-arthrography additionally was performed. MR-examinations were correlated with clinical findings; MR and arthroscopy scores were statistically compared, agreement was measured. Results: Arthroscopy demonstrated granulation tissue in the lateral gutter (38%) and anterior recess (31%), lesions of the anterior tibiofibular (31%) and the anterior talofibular ligament (21%) as well as intraarticular bodies (10%). Stenosing tenosynovitis and a ganglionic cyst were revealed as extraarticular causes for chronic ankle pain by MR-examination (17%). Agreement of MR-imaging and arthroscopy was fair for the anterior talofibular ligament and the anterior joint cavity (kappa 0.40). Major discrepancy was found for non-enhanced MR scans (kappa 0.49) when compared with indirect MR-arthrography (kappa 0.03) in the anterior cavity. The sensitivity for lesions of the anterior talofibular and calcaneofibular ligament and the anterior cavity (0.91-0.87) detected by MR-imaging was superior in comparison to lesions of the anterior tibiofibular ligament and anteromedial cavity (0.50-0.24). Conclusion: MR-imaging provides additional information about the mechanics of chronic ankle impingement rather than an accurate diagnosis of this clinical entity. The method is helpful in differentiating extra- from intra-articular causes of ankle impingement. Indirect MR-arthrography has little or no additional value in patients with ankle impingement syndrome

  15. Chemical and physical oceanographic profile data collected from CTD casts aboard NOAA Ship NANCY FOSTER in the Gulf of Mexico from 2010-08-13 to 2010-08-21 in response to the Deepwater Horizon oil spill event (NODC Accession 0069614)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Chemical and physical oceanographic profile data were collected aboard NOAA Ship NANCY FOSTER in the Gulf of Mexico from 2010-08-13 to 2010-08-21 in response to the...

  16. Phase transition and conduction mechanism in Pb{sub 2}Na{sub 0.8}R{sub 0.2}Nb{sub 4.8}Fe{sub 0.2}O{sub 15} material (R=rare earth)

    Energy Technology Data Exchange (ETDEWEB)

    Bouziane, M. [Laboratoire de Chimie du Solide Appliquée, Faculté des Sciences, Université Mohammed V-Agdal, Avenue Ibn Batouta, BP 1014 Rabat (Morocco); Taibi, M., E-mail: taibiens@yahoo.fr [Laboratoire de Physico-Chimie des Matériaux (LAF 502), Ecole Normale Supérieure, Université Mohammed V-Agdal, BP 5118 Rabat (Morocco); Boukhari, A. [Laboratoire de Chimie du Solide Appliquée, Faculté des Sciences, Université Mohammed V-Agdal, Avenue Ibn Batouta, BP 1014 Rabat (Morocco)

    2013-11-15

    Electrical properties of Pb{sub 2}Na{sub 0.8}Eu{sub 0.2}Nb{sub 4.8}Fe{sub 0.2}O{sub 15} tungsten bronze compound were investigated. Ferroelectric phase transition of diffuse type is observed at 395 °C. Conductivity study as a function of temperature (RT-600 °C) and at three different frequencies (10, 100 and 1000 kHz) suggests the existence of dominant ionic conduction. The rise of ac conductivity on increasing temperature supports the NTCR (negative temperature coefficient of resistance) behaviour of the material. The activation energies have been evaluated from ac conductivity using Arrhenius equation and discussed. Different conduction mechanisms were identified. For comparison, the conducting properties of Pb{sub 2}Na{sub 0.8}R{sub 0.2}Nb{sub 4.8}Fe{sub 0.2}O{sub 15} (R=Dy, Nd, La) were also investigated. - Graphical abstract: Thermal evolution of lnσ{sub ac} of Pb{sub 2}Na{sub 0.8}Eu{sub 0.2}Nb{sub 4.8}Fe{sub 0.2}O{sub 15} at selected frequencies. Display Omitted - Highlights: • We found that TB compounds exhibit a diffuse type of first- order transition. • A negative temperature coefficient of resistance (NTCR) behaviour is observed. • Three conduction mechanisms were identified: n-and/or p-type at low temperatures. • The conduction mechanism in the studied compounds is very complex.

  17. Coronary Artery Anomalies and Variants: Technical Feasibility of Assessment with Coronary MR Angiography at 3 T1

    Science.gov (United States)

    Gharib, Ahmed M.; Ho, Vincent B.; Rosing, Douglas R.; Herzka, Daniel A.; Stuber, Matthias; Arai, Andrew E.; Pettigrew, Roderic I.

    2008-01-01

    The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant study was approved by the local institutional review board, and informed consent was obtained from all participants. Twenty-two participants (11 men, 11 women; age range, 18–62 years) were included. Ten participants were healthy volunteers, whereas 12 participants were patients suspected of having CAAV. Coronary MR angiography was performed with a 3-T MR imager. A 3D free-breathing navigator-gated and vector electrocardiographically–gated segmented k-space gradient-echo sequence with adiabatic T2 preparation pulse and parallel imaging (sensitivity encoding) was used. Whole-heart acquisitions (repetition time msec/echo time msec, 4/1.35; 20° flip angle; 1 × 1 × 2-mm acquired voxel size) lasted 10–12 minutes. Mean examination time was 41 minutes ± 14 (standard deviation). Findings included aneurysms, ectasia, arteriovenous fistulas, and anomalous origins. The 3D whole-heart acquisitions developed for use with 3 T are feasible for use in the assessment of CAAV. © RSNA, 2008 PMID:18372470

  18. Accuracy evaluation of fusion of CT, MR, and SPECT images using commercially available software packages (SRS PLATO and IFS)

    International Nuclear Information System (INIS)

    Mongioj, Valeria; Brusa, Anna; Loi, Gianfranco; Pignoli, Emanuele; Gramaglia, Alberto; Scorsetti, Marta; Bombardieri, Emilio; Marchesini, Renato

    1999-01-01

    Purpose: A problem for clinicians is to mentally integrate information from multiple diagnostic sources, such as computed tomography (CT), magnetic resonance (MR), and single photon emission computed tomography (SPECT), whose images give anatomic and metabolic information. Methods and Materials: To combine this different imaging procedure information, and to overlay correspondent slices, we used commercially available software packages (SRS PLATO and IFS). The algorithms utilize a fiducial-based coordinate system (or frame) with 3 N-shaped markers, which allows coordinate transformation of a clinical examination data set (9 spots for each transaxial section) to a stereotactic coordinate system. The N-shaped markers were filled with fluids visible in each modality (gadolinium for MR, calcium chloride for CT, and 99m Tc for SPECT). The frame is relocatable, in the different acquisition modalities, by means of a head holder to which a face mask is fixed so as to immobilize the patient. Position errors due to the algorithms were obtained by evaluating the stereotactic coordinates of five sources detectable in each modality. Results: SPECT and MR position errors due to the algorithms were evaluated with respect to CT: Δx was ≤ 0.9 mm for MR and ≤ 1.4 mm for SPECT, Δy was ≤ 1 mm and ≤ 3 mm for MR and SPECT, respectively. Maximal differences in distance between estimated and actual fiducial centers (geometric mismatch) were in the order of the pixel size (0.8 mm for CT, 1.4 mm for MR, and 1.8 mm for SPECT). In an attempt to distinguish necrosis from residual disease, the image fusion protocol was studied in 35 primary or metastatic brain tumor patients. Conclusions: The image fusion technique has a good degree of accuracy as well as the potential to improve the specificity of tissue identification and the precision of the subsequent treatment planning

  19. 77 FR 65545 - Mr. Jesse S. Capel and Mr. Hilton J. Cochran; EWP LLC; Notice of Transfer of Exemption

    Science.gov (United States)

    2012-10-29

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 4815-009] Mr. Jesse S. Capel and Mr. Hilton J. Cochran; EWP LLC; Notice of Transfer of Exemption 1. By application filed on July 30, 2012 and supplemented on August 14, 2012, Mr. Jesse S. Capel and Mr. Hilton J. Cochran and EWP...

  20. Processing of acquisition data for a time of flight positron tomograph

    International Nuclear Information System (INIS)

    Robert, G.

    1987-10-01

    After a review of basic principles concerning the time of flight positron tomography, the LETI positron tomograph is briefly described. For performance optimization (acquisition, calibration, image reconstruction), various specialized operators have been designed: the realization of the acquisition system is presented [fr

  1. Monte Carlo determinations of the functions Λ(r, Z), G(r, θ), g(R) and F(r, θ) for Amersham CDCS-M-type 137Cs source

    International Nuclear Information System (INIS)

    Valdez, F. Roberto Fragoso; Alvarez Romero, J. Trinidad

    2001-01-01

    The functions Λ(r, z), G(r, θ), g(r) and F(r, θ) were calculated for Amersham model CDCS-M-type 137 Cs source by means of Monte Carlo simulation using the algorithm PENELOPE. These functions are required to verify and/or to feed planning systems or directly as entrance data for the manual planning of the distribution of absorbed dose according with the recommendations of the TG 43, [1]. The values of the constant Λ (r, Z) were determined as the quotient of absorbed dose rate distribution in water and air kerma strength in 'free air' S k . The values obtained for Λ (r, Z) differ up to 3% of those reported in the literature, being very sensitive to the cutoff energy for the electrons in the interface of the source's encapsulated and water

  2. MR myelography of sacral meningeal cysts

    International Nuclear Information System (INIS)

    Tsuchiya, K.; Katase, S.; Hachiya, J.

    1999-01-01

    Purpose: To describe the findings of sacral meningeal cysts (SMCs) on MR myelography and assess its value for the diagnosis of SMCs. Material and Methods: We evaluated the MR images and MR myelograms obtained from 10 patients with SMC. MR myelograms were obtained using a 2D or 3D single-shot fast spin-echo sequence. In 5 patients, X-ray myelograms and postmyelographic CT images were compared with the MR myelograms. Results: A total of 33 SMCs were diagnosed within the spinal canal and/or sacral foramen. MR myelograms clearly revealed each cyst as a well-defined mass showing hyperintensity (10 cysts) or isointensity (23 cysts) compared to cerebrospinal fluid. MR myelograms demonstrated SMCs better than X-ray myelograms and postmyelographic CT images in 3 of the 5 patients. Conclusion: MR myelography can be an adjunct to conventional imaging techniques when surgical treatment is indicated, because it can precisely delineate the extent of SMCs. (orig.)

  3. Evaluation of the pedal artery: comparison of three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Kang, Sung Gwon; Byun, Joo Nam; Kim, Young Cheol; Choi, Jeong Yeol; Kim, Dong Hyun [College of Medicine, Chosun Univ., Kwangju (Korea, Republic of)

    2002-07-01

    To compare the three-dimensional gadolinium-enhanced MR angiography with digital subtraction angiography (DSA) for evaluation of the pedal artery. In 12 extremities of 11 patients, both digital subtraction angiography (DSA) and contrast-enhanced MR angiography (CE-MR angiography) were performed during the same week. Among ten of the 11 patients, the following conditions were present: atherosclerosis (n=4), diabetic foot (n=3), Buerger's disease (n=1), calciphylactic arteriopathy (n=1) and arteriovenous malformation of the foot (n=1). The remaining patient underwent angiography prior to flap surgery. For MR angiography, a 1.5T system using an extremity or head coil was used. A three-dimensional FISP (fast imaging with steady state precession) sequence was obtained before enhancement, followed by four sequential acquisitions (scan time, 20 secs, scan interval time, 10 secs) 10 seconds after intravenous bolus injection of normal saline (total 10 cc), following intravenous administration of gadolinium (0.02 mmol/kg, 3 ml/sec). Arterial segments of the ankle and foot were classified as the anterior or posterior tibial artery, the distal peroneal artery, the medial or lateral plantar artery, the pedal arch, and the dorsalis pedis artery. Two radiologists independently analysed visualization of each arteraial segment and the mean of visible arterial segments in one extreminty using CE-MR angiography and DSA. Among 84 arterial segments, 16 were invisible at both CE-MR angiography and DSA, while 39 were demonstrated by both modalities. Twenty-six segments were visible only at CE-MR angiography and three only at DSA. CE-MR angiography displayed a higher number of arterial segments than DSA (mean, 5.42 vs. mean 3.50, respectively), a difference which was statistically significant (p<0.000). The difference between each arterial segment was not statistically significant, except for the dorsalis pedis artery (t test, p<0.000). In that it provides additional information for

  4. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    International Nuclear Information System (INIS)

    Izquierdo-Garcia, David; Sawiak, Stephen J.; Knesaurek, Karin; Machac, Joseph; Narula, Jagat; Fuster, Valentin; Fayad, Zahi A.

    2014-01-01

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R 2 = 0.98, p 2 = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  5. A transaction cost analysis of micropayments in mobile commerce

    OpenAIRE

    Gille, Daniel

    2005-01-01

    Personalised, location-related and differentiated services in the mobile digital economy create a demand for suitable pricing models. In the case of disaggregated “microservices” (e.g., small digitalized information or service units), as well as for the acquisition of low-value physical goods, the deployment of micropayments seems appropriate. This paper analyzes the economic efficiency of marginal transaction amounts in the m-commerce area by applying the theoretical approach of transact...

  6. m-Commerce

    OpenAIRE

    VACKOVÁ, Kateřina

    2013-01-01

    The aim of this thesis was to suggest practical use of m-commerce in the company Elektra PV based on analysis of options of m-commerce in the Czech Republic and in the world. First part of this thesis investigates theoretical basics of mobile commerce. Next part processes three case studies about the companies Amazon, Argos and Alza.cz, then followed the analysis of m-commerce. Based on previous findings is suggested for the company Elektra PV to implement mobile application.

  7. Investigation of spatial correlation in MR images of human cerebral white matter using geostatistical methods

    Energy Technology Data Exchange (ETDEWEB)

    Keil, Fabian

    2014-03-20

    %. This means that MR variography provides an easy way to characterise and to compare datasets from cross-sectional or longitudinal studies investigating neurological and neuroscientific questions, even with large subject groups. Furthermore, it can provide useful additional information to other advanced structure analysing methods. Finally, the power and usefulness of MR variography was demonstrated by means of two application examples. First, the relation of spatial correlation parameters and age was investigated by means of 24 datasets of healthy, female volunteers. It was shown that white matter heterogeneity is strongly positively correlated to age up to distances of 3 mm (r=0.83, p<10{sup -6}). These findings are in good accordance with results obtained with other advanced structure analysis techniques, such as e.g. diffusion tensor imaging but benefits from much shorter image acquisition times and easier data processing. The second application example includes the investigation of advances and drawbacks of using quantitative MR maps as data basis for MR variography. The correlation parameters obtained from quantitative data were shown to be interpreted more easily, but prevalently the price of less accurate results has to be paid, as quantitative maps have properties which complicate the variographic analysis.

  8. Normal variation and long-term reproducibility of image-selected in vivo brain MR spectroscopy

    International Nuclear Information System (INIS)

    Smith, M.A.; Porter, D.; Lowry, M.; Ayton, V.; Twelves, C.J.; Richards, M.A.; Garlick, P.; Maisey, M.N.

    1988-01-01

    MR spectroscopy of P-31 in the brain was performed with a 1.5-T MR imaging and spectroscopy system using ISIS with a 5-cm cube. A standardized spectral processing routine was adopted, and the ratios of peak areas were measured. Localized brain spectra were obtained from 17 healthy subjects, of whom ten had undergone repeated investigations after a delay of at least 1 month. The variation among healthy subjects, expressed as the mean +- standard deviation, and the long-term reproducibility, expressed as the coefficient of variation, were as follows: for peak areas phosphocreatine (PCr) Pi 2.46 +- 0.72, 21.3%, for PCr/PME, 1.97 +- 0.62, 16.8%, for PCr/PDE, 0.51 +- 0.07, 8.1%; for PCr/Υ-adenosine triphosphate (ATP), 1.13 + 0.15, 6.3%; for PCr/α-ATP, 1.09 +- 0.21, 10.3%, for PCr/β-ATP, 1.66 +- .027, 10.4%; and for pH, 7.00 +- 0.05, 0.8%

  9. MR-Guided Pulsed High-Intensity Focused Ultrasound Enhancement of Gene Therapy Combined With Androgen Deprivation and Radiotherapy for Prostate Cancer Treatment

    Science.gov (United States)

    2009-09-01

    ultrasound . J. Acoust. Soc.Am. 72 1926-1932, (1982) (7) Neppiras E A. Acoustic cavitation . Physics reports 61(3): 159-251, (1980) (8) ter Haar G R, Daniels...Guided Pulsed High-Intensity Focused Ultrasound Enhancement of 5b. GRANT NUMBER W81XWH-08-1-0469 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...failing to This work is aimed to study MR guided high intensity focused ultrasound (MRgHIFU) enhancement of gene therapy for Prostate Cancer. The

  10. Hepatic iron overload: Quantitative MR imaging

    International Nuclear Information System (INIS)

    Gomori, J.M.; Horev, G.; Tamary, H.; Zandback, J.; Kornreich, L.; Zaizov, R.; Freud, E.; Krief, O.; Ben-Meir, J.; Rotem, H.

    1991-01-01

    Iron deposits demonstrate characteristically shortened T2 relaxation times. Several previously published studies reported poor correlation between the in vivo hepatic 1/T2 measurements made by means of midfield magnetic resonance (MR) units and the hepatic iron content of iron-overloaded patients. In this study, the authors assessed the use of in vivo 1/T2 measurements obtained by means of MR imaging at 0.5 T using short echo times (13.4 and 30 msec) and single-echo-sequences as well as computed tomographic (CT) attenuation as a measure of liver iron concentration in 10 severely iron-overloaded patients with beta-thalassemia major. The iron concentrations in surgical wedge biopsy samples of the liver, which varied between 3 and 9 mg/g of wet weight (normal, less than or equal to 0.5 mg/g), correlated well (r = .93, P less than or equal to .0001) with the preoperative in vivo hepatic 1/T2 measurements. The CT attenuation did not correlate with liver iron concentration. Quantitative MR imaging is a readily available noninvasive method for the assessment of hepatic iron concentration in iron-overloaded patients, reducing the need for needle biopsies of the liver

  11. Early evaluation of irradiated parotid glands with intravoxel incoherent motion MR imaging: correlation with dynamic contrast-enhanced MR imaging

    International Nuclear Information System (INIS)

    Zhou, Nan; Chu, Chen; Dou, Xin; Li, Ming; Liu, Song; Zhu, Lijing; Liu, Baorui; Guo, Tingting; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng; Liu, Tian

    2016-01-01

    Radiation-induced parotid damage is one of the most common complications in patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy (RT). Intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging has been reported for evaluating irradiated parotid damage. However, the changes of IVIM perfusion-related parameters in irradiated parotid glands have not been confirmed by conventional perfusion measurements obtained from dynamic contrast-enhanced (DCE) MR imaging. The purposes of this study were to monitor radiation-induced parotid damage using IVIM and DCE MR imaging and to investigate the correlations between changes of these MR parameters. Eighteen NPC patients underwent bilateral parotid T1-weighted, IVIM and DCE MR imaging pre-RT (2 weeks before RT) and post-RT (4 weeks after RT). Parotid volume; IVIM MR parameters, including apparent diffusion coefficient (ADC), pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f); and DCE MR parameters, including maximum relative enhancement (MRE), time to peak (TTP), Wash in Rate, and the degree of xerostomia were recorded. Correlations of parotid MR parameters with mean radiation dose, atrophy rate and xerostomia degree, as well as the relationships between IVIM and DCE MR parameters, were investigated. From pre-RT to post-RT, all of the IVIM and DCE MR parameters increased significantly (p < 0.001 for ADC, D, f, MRE, Wash in Rate; p = 0.024 for D*; p = 0.037 for TTP). Change rates of ADC, f and MRE were negatively correlated with atrophy rate significantly (all p < 0.05). Significant correlations were observed between the change rates of D* and MRE (r = 0.371, p = 0.026) and between the change rates of D* and TTP (r = 0.396, p = 0.017). The intra- and interobserver reproducibility of IVIM and DCE MR parameters was good to excellent (intraclass correlation coefficient, 0.633–0.983). Early radiation-induced changes of parotid glands could be evaluated by IVIM and

  12. 78 FR 6188 - Federal Acquisition Regulation; Free Trade Agreement-Colombia

    Science.gov (United States)

    2013-01-29

    ... Promotion Agreement. This Trade Promotion Agreement is a free trade agreement (FTA) that provides for... 77 FR 27548 on May 10, 2012, to implement the United States-Colombia Trade Promotion Agreement... and safety effects, distributive impacts, and equity). E.O. 13563 emphasizes the importance of...

  13. 77 FR 31155 - Providing an Order of Succession Within the Department of Commerce

    Science.gov (United States)

    2012-05-24

    ... Providing an Order of Succession Within the Department of Commerce By the authority vested in me as... forth in the Act, the following officials of the Department of Commerce, in the order listed, shall act as and perform the functions and duties of the office of the Secretary of Commerce (Secretary) during...

  14. An Overview of Advanced Data Acquisition System (ADAS)

    Science.gov (United States)

    Mata, Carlos T.; Steinrock, T. (Technical Monitor)

    2001-01-01

    The paper discusses the following: 1. Historical background. 2. What is ADAS? 3. R and D status. 4. Reliability/cost examples (1, 2, and 3). 5. What's new? 6. Technical advantages. 7. NASA relevance. 8. NASA plans/options. 9. Remaining R and D. 10. Applications. 11. Product benefits. 11. Commercial advantages. 12. intellectual property. Aerospace industry requires highly reliable data acquisition systems. Traditional Acquisition systems employ end-to-end hardware and software redundancy. Typically, redundancy adds weight, cost, power consumption, and complexity.

  15. Online Canton Fairs Ready for Convenient Trade--An Interview with Ding Qiang, General Manager of MOFCOM China International Electronic Commerce Center

    Institute of Scientific and Technical Information of China (English)

    Li Yinghong; Sun Yongjian

    2006-01-01

    @@ In 2006, the Canton Fairs will greet the 99th and 100th respectively in spring and fall. To meet the need of the development of the convenient trade, the Canton Fairs website, the platform of the online Canton Fairs run by MOFCOM China International Electronic Commerce Center is ready to take several effective measures to offer more convenient services. On March 24, China's Foreign Trade took the occasion to interview with Mr. Ding Qiang, General Manager of MOFCOM China International Electronic Commerce Center.

  16. Superfund reauthorization. Hearings before the Subcommittee on Commerce, Transportation, and Tourism of the Committee on Energy and Commerce, House of Representatives, Ninety-Eighth Congress, Second Session on H. R. 4813 and H. R. 4915, February 28, March 1, 8, and 15, 1984

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    Four days of hearings on two bills (H.R. 4813 and H.R. 4915) designed to provide cleanup funds for hazardous waste sites cover the testimony of 42 witnesses, including that of Environmental Protection Agency Director Ruckelshaus and representatives of the US Chamber of Commerce, government agencies, environmental and other interest groups, the medical profession, the chemical and mining industries, and waste treatment agencies and organizations. The three-year-old Superfund has only cleaned up a few sites, and EPA predicts that the $1.6 billion fund can handle only 170 of the 546 priority sites. The reauthorizing bills increase funding, set cleanup standards, increase enforcement provisions, and encourage a state and federal partnership in the cleanup process. Material submitted for the record follows the text of the two bills and the testimony.

  17. Merging Platform Ecosystems in Technology Acquisitions

    DEFF Research Database (Denmark)

    Dowie, Jamie; Henningsson, Stefan; Kude, Thomas

    2017-01-01

    of the merging companies. Given the increasing importance of platforms and value co-creation with third-party providers for companies making technology acquisitions, we complement existing literature by reframing the analysis of technology acquisitions to include the merger of the broader partner ecosystems....... Specifically, we draw on theories of ecosystem governance to analyze how ecosystem tensions unfolded during the ecosystem merger and how the acquirer governed these tensions in SAP SE’s acquisition of the e-commerce provider Hybris AG. Our findings suggest that the governance of ecosystem tensions...... is an important aspect of managing technology acquisitions. We identify the pre-acquisition relation between the acquired company’s ecosystem partners and the acquirer as an important context factor for explaining how a partner company is exposed to the ecosystem tensions during the merger....

  18. Effect of Attenuation Correction on Regional Quantification Between PET/MR and PET/CT

    DEFF Research Database (Denmark)

    Teuho, Jarmo; Johansson, Jarkko; Linden, Jani

    2016-01-01

    UNLABELLED: A spatial bias in brain PET/MR exists compared with PET/CT, because of MR-based attenuation correction. We performed an evaluation among 4 institutions, 3 PET/MR systems, and 4 PET/CT systems using an anthropomorphic brain phantom, hypothesizing that the spatial bias would be minimized....../MR systems, CTAC was applied as the reference method for attenuation correction. RESULTS: With CTAC, visual and quantitative differences between PET/MR and PET/CT systems were minimized. Intersystem variation between institutions was +3.42% to -3.29% in all VOIs for PET/CT and +2.15% to -4.50% in all VOIs...... for PET/MR. PET/MR systems differed by +2.34% to -2.21%, +2.04% to -2.08%, and -1.77% to -5.37% when compared with a PET/CT system at each institution, and these differences were not significant (P ≥ 0.05). CONCLUSION: Visual and quantitative differences between PET/MR and PET/CT systems can be minimized...

  19. CAMAC acquisition system for industrial X-ray tomograph

    International Nuclear Information System (INIS)

    Guerin, J.P.; Huet, Jacques; Pauton, Michel.

    1982-11-01

    A 400 kV X-ray industrial scanner has been developed. The present paper describes the CAMAC acquisition system. This unit with its 3 microprocessors, 2 mass memories and TV graphic display is very flexible; it will be used to optimise measurement parameters along with pieces to be checked and to establish application limits of this non destructive inspection method. This system allows internal inspection of objects as big as 400 mm in diameter with an elementary volume of 1 x 1 x 5 mm 3 and specific weight in the range of 0.7 to 10 g/cm 3 . Relative precision of 10 - 3 in density for moulded objects is expected. The first results obtained are shown [fr

  20. 76 FR 24862 - Meeting of a Federal Advisory Committee

    Science.gov (United States)

    2011-05-03

    ... minutes. 9:15 a.m. Defense Acquisition Workforce Talent Management Initiative. 10:45 a.m. Army Senior... Liaison Officer, Department of Defense. [FR Doc. 2011-10679 Filed 5-2-11; 8:45 am] BILLING CODE 5001-06-P ...

  1. Nonlinear evolution of f(R) cosmologies. II. Power spectrum

    International Nuclear Information System (INIS)

    Oyaizu, Hiroaki; Hu, Wayne; Lima, Marcos

    2008-01-01

    We carry out a suite of cosmological simulations of modified action f(R) models where cosmic acceleration arises from an alteration of gravity instead of dark energy. These models introduce an extra scalar degree of freedom which enhances the force of gravity below the inverse mass or Compton scale of the scalar. The simulations exhibit the so-called chameleon mechanism, necessary for satisfying local constraints on gravity, where this scale depends on environment, in particular, the depth of the local gravitational potential. We find that the chameleon mechanism can substantially suppress the enhancement of power spectrum in the nonlinear regime if the background field value is comparable to or smaller than the depth of the gravitational potentials of typical structures. Nonetheless power spectrum enhancements at intermediate scales remain at a measurable level for models even when the expansion history is indistinguishable from a cosmological constant, cold dark matter model. Simple scaling relations that take the linear power spectrum into a nonlinear spectrum fail to capture the modifications of f(R) due to the change in collapsed structures, the chameleon mechanism, and the time evolution of the modifications.

  2. MR findings of brainstem injury

    Energy Technology Data Exchange (ETDEWEB)

    Park, Man Soo; Hwang, Woo Cheol; Park, Choong Ki [Hallym University College of Medicine, Seoul (Korea, Republic of); Suh, Dae Chul [University of Ulsan College of Medicine, Seoul (Korea, Republic of); Kim, Sang Joon [Dankook University of College of Medicine, Cheonan (Korea, Republic of)

    1995-02-15

    To analyze the characteristics of traumatic brainstem injury by CT and MR. CT and MR studies of 10 patients with traumatic brainstem lesion in MR were retrospectively reviewed, particularly attended to location, signal intensity and associated lesions. CT failed to depict 8 of 10 brainstem lesions. All lesions were detected in MR images with T2-weighted images showing higher detection rate (n = 10) (100%) than T1-weighted images (n = 3) (30%) or CT (n = 2) (20%). The brainstem lesions located in the dorsolateral aspects of the rostral brainstem (mid brain and upper pons) in 7 (70%) cases, in ventral aspects of rostral brain in 2 (20%) cases and in median portion of pons in 1 (10%) case. Corpus callosal (n = 5), lobar white matter (n = 5) diffuse axonal injury, and 2 hemorrhagic lesions in basal ganglia were the associated findings. MR imaging is more helpful than CT in the detection of brainstem injury, especially T2 weighted images. Primary brainstem lesions were typically located in the dorsolateral aspect of rostral brainstem (midbrain and upper pons). Corpus callosum and white matter lesions were frequently associated.

  3. Slow phasic changes in nucleus accumbens dopamine release during fixed ratio acquisition: a microdialysis study.

    Science.gov (United States)

    Segovia, K N; Correa, M; Salamone, J D

    2011-11-24

    Nucleus accumbens dopamine (DA) is a critical component of the brain circuitry regulating behavioral output during reinforcement-seeking behavior. Several studies have investigated the characteristics of accumbens DA release during the performance of well-learned operant behaviors, but relatively few have focused on the initial acquisition of particular instrumental behaviors or operant schedules. The present experiments focused on the initial acquisition of operant performance on a reinforcement schedule by studying the transition from a fixed ratio 1 (FR1) schedule to another operant schedule with a higher ratio requirement (i.e. fixed ratio 5 [FR5]). Microdialysis sessions were conducted in different groups of rats that were tested on either the FR1 schedule; the first, second, or third day of FR5 training; or after weeks of FR5 training. Consistent with previous studies, well-trained rats performing on the FR5 schedule after weeks of training showed significant increases in extracellular DA in both core and shell subregions of nucleus accumbens during the behavioral session. On the first day of FR5 training, there was a substantial increase in DA release in nucleus accumbens shell (i.e. approximately 300% of baseline). In contrast, accumbens core DA release was greatest on the second day of FR5 training. In parallel experiments, DA release in core and shell subregions did not significantly increase during free consumption of the same high carbohydrate food pellets that were used in the operant experiments, despite the very high levels of food intake in experienced rats. However, in rats exposed to the high-carbohydrate food for the first time, there was a tendency for extracellular DA to show a small increase. These results demonstrate that transient increases in accumbens DA release occur during the initial acquisition of ratio performance, and suggest that core and shell subregions show different temporal patterns during acquisition of instrumental behavior

  4. Effect of Ca substitution on the electrochemical properties of the Ruddlesden-Popper oxides Sr3.2-xCaxLn0.8Fe1.5Co1.5O10

    Science.gov (United States)

    Padmasree, K. P.; Lai, Ke-Yu; Kaveevivitchai, Watchareeya; Manthiram, Arumugam

    2018-01-01

    The Ruddlesden-Popper (R-P) oxides Sr3.2-xCaxLn0.8Fe1.5Co1.5O10-δ with x = 0 and 0.4 and Ln = La, Pr, and Nd, have been synthesized and the effect of Ca on their electrochemical properties as cathodes in solid oxide fuel cells (SOFC) has been investigated. The substitution of Ca for Sr in Sr3.2-xCaxLn0.8Fe1.5Co1.5O10-δ decreases the amount of oxygen loss on heating and the thermal expansion coefficient (TEC). The phase instability of these materials at high temperature is a significant issue that restricts their application as SOFC cathodes, and the substitution of Ca effectively stabilizes the Sr3.2-xCaxLn0.8Fe1.5Co1.5O10-δ phase at 800 °C. Among the different lanthanides with and without Ca in Sr3.2-xCaxLn0.8Fe1.5Co1.5O10-δ, the Ln = Nd samples exhibit an enhancement in cathode performance in SOFC compared to Ln = La and Pr samples, which may be attributed to the higher concentration of oxygen vacancies in the Ln = Nd samples. Comparing the various compositions studied, the Sr2.8Ca0.4Nd0.8Fe1.5Co1.5O10-δ cathode material exhibits superior performance in SOFC with good phase stability.

  5. Tribocorrosion behaviour of 08CH18N10T steel

    International Nuclear Information System (INIS)

    Kubecka, P.; Tvrdy, M.; Wenger, F.; Ponthiaux, P.

    2000-01-01

    Tribocorrosion of the 08CH18N10T austenitic stainless steel in a potassium sulphate solution was investigated with the help of pin-on-disk tribometer and polarisation curves method. The results indicate the occurrence of synergetic interactions between electrochemical and mechanical conditions: the damaging of the passive film by friction was pointed out, leading to an increase in the dissolution rate of the metal and simultaneously, the occurrence of electrochemical reactions (gas evolution, dissolution, passivation) was found to modify the tribological conditions (friction coefficient). (author)

  6. Semiautomated spleen volumetry with diffusion-weighted MR imaging.

    Science.gov (United States)

    Lee, Jeongjin; Kim, Kyoung Won; Lee, Ho; Lee, So Jung; Choi, Sanghyun; Jeong, Woo Kyoung; Kye, Heewon; Song, Gi-Won; Hwang, Shin; Lee, Sung-Gyu

    2012-07-01

    In this article, we determined the relative accuracy of semiautomated spleen volumetry with diffusion-weighted (DW) MR images compared to standard manual volumetry with DW-MR or CT images. Semiautomated spleen volumetry using simple thresholding followed by 3D and 2D connected component analysis was performed with DW-MR images. Manual spleen volumetry was performed on DW-MR and CT images. In this study, 35 potential live liver donor candidates were included. Semiautomated volumetry results were highly correlated with manual volumetry results using DW-MR (r = 0.99; P volumetry was significantly shorter compared to that of manual volumetry with DW-MR (P volumetry with DW-MR images can be performed rapidly and accurately when compared with standard manual volumetry. Copyright © 2011 Wiley Periodicals, Inc.

  7. Fetal cleft lip with and without cleft palate: Comparison between MR imaging and US for prenatal diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang Guangbin, E-mail: wgb7932596@hotmail.com [Shandong Medical Imaging Research Institute, 324 Jingwu Road, Jinan, 250021 (China); Shan Ruiqin [Jinan Maternity and Child Care Hospital, Jinan (China); Zhao Lianxin; Zhu Xiangyu; Zhang Xinjuan [Shandong Medical Imaging Research Institute, 324 Jingwu Road, Jinan, 250021 (China)

    2011-09-15

    Objective: To describe the magnetic resonance (MR) imaging findings of fetal CL/CP and evaluate its diagnostic value. Methods and materials: Twelve fetuses with CL/CP diagnosed by transabdominal US underwent MR imaging within 2 days of US. Half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence on T2-weighted images was performed on sagittal, coronal, and axial planes anatomic to the fetuses during maternal breath holding. US and MR imaging findings were compared with final diagnoses obtained from post-natal physical examination or fetal autopsy. Results: Final diagnoses confirmed incomplete midline cleft lip (n = 1), unilateral cleft lip and palate (n = 7), bilateral cleft lip and palate (n = 1), midline cleft lip and palate (n = 3). US and MR imaging diagnosed all 12 fetuses with cleft lip and the laterality. 5 (45.5%) of 11 cleft palates were identified with US, 2 of 7 fetuses with unilateral cleft palate, 2 of 3 fetuses with midline cleft palate, and one fetus with bilateral cleft palate. On MR imaging, 10 (91%) of 11 cleft palates were correctly detected. One fetus with unilateral cleft palate was not detected. No false-positives occurred. Conclusion: MR imaging is valuable for diagnosis of fetal CL/CP. It can demonstrate additional findings and provide more information compared with US.

  8. Fetal cleft lip with and without cleft palate: Comparison between MR imaging and US for prenatal diagnosis

    International Nuclear Information System (INIS)

    Wang Guangbin; Shan Ruiqin; Zhao Lianxin; Zhu Xiangyu; Zhang Xinjuan

    2011-01-01

    Objective: To describe the magnetic resonance (MR) imaging findings of fetal CL/CP and evaluate its diagnostic value. Methods and materials: Twelve fetuses with CL/CP diagnosed by transabdominal US underwent MR imaging within 2 days of US. Half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence on T2-weighted images was performed on sagittal, coronal, and axial planes anatomic to the fetuses during maternal breath holding. US and MR imaging findings were compared with final diagnoses obtained from post-natal physical examination or fetal autopsy. Results: Final diagnoses confirmed incomplete midline cleft lip (n = 1), unilateral cleft lip and palate (n = 7), bilateral cleft lip and palate (n = 1), midline cleft lip and palate (n = 3). US and MR imaging diagnosed all 12 fetuses with cleft lip and the laterality. 5 (45.5%) of 11 cleft palates were identified with US, 2 of 7 fetuses with unilateral cleft palate, 2 of 3 fetuses with midline cleft palate, and one fetus with bilateral cleft palate. On MR imaging, 10 (91%) of 11 cleft palates were correctly detected. One fetus with unilateral cleft palate was not detected. No false-positives occurred. Conclusion: MR imaging is valuable for diagnosis of fetal CL/CP. It can demonstrate additional findings and provide more information compared with US.

  9. Spherically Symmetric Geometries in f(T) and f(R) Gravitational Theories

    International Nuclear Information System (INIS)

    Nashed, Gamal G. L.

    2015-01-01

    Using the well know relation between Ricci scalar, R, and torsion scalar, T, that is, R=-T-2∇_αT"α, we show that, for any spherically symmetric spacetime whose (i) scalar torsion vanishing, that is, T=T_μ_ν"αS_α"μ"ν=0 or (ii) total derivative term, that is, ∇_αT"α with T"α is the contraction of the torsion, vanishing, or (iii) the combination of scalar torsion and total derivative term vanishing, could be solution for f(T) and f(R) gravitational theories.

  10. MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open high-field MRI scanner with respiratory gating

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ming; Huang, Jie; Xu, Yujun; He, Xiangmeng; Lue, Yubo; Liu, Qiang; Li, Chengli [Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong (China); Li, Lei [Qingdao Central Hospital, Department of Interventional Radiology, Qingdao, Shandong (China); Blanco Sequeiros, Roberto [Turku University Hospital, The South Western Finland Imaging Centre, Turku (Finland)

    2017-04-15

    To prospectively evaluate the feasibility, safety and accuracy of MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open MR scanner with respiratory gating. Sixty-five patients with 65 solitary pulmonary lesions underwent MR-guided percutaneous coaxial cutting needle biopsy using a 1.0-T open MR scanner with respiratory gating. Lesions were divided into two groups according to maximum lesion diameters: ≤2.0 cm (n = 31) and >2.0 cm (n = 34). The final diagnosis was established in surgery and subsequent histology. Diagnostic accuracy, sensitivity and specificity were compared between the groups using Fisher's exact test. Accuracy, sensitivity and specificity of MRI-guided percutaneous pulmonary biopsy in diagnosing malignancy were 96.9 %, 96.4 % and 100 %, respectively. Accuracy, sensitivity and specificity were 96.8 %, 96.3 % and 100 % for lesions 2.0 cm or smaller and 97.1 %, 96.4 % and 100 %, respectively, for lesions larger than 2.0 cm. There was no significant difference between the two groups (P > 0.05). Biopsy-induced complications encountered were pneumothorax in 12.3 % (8/65) and haemoptysis in 4.6 % (3/65). There were no serious complications. MRI-guided percutaneous biopsy using a 1.0-T open MR scanner with respiratory gating is an accurate and safe diagnostic technique in evaluation of pulmonary lesions. (orig.)

  11. Electronic Commerce

    Directory of Open Access Journals (Sweden)

    Slavko Đerić

    2016-12-01

    Full Text Available Electronic commerce can be defined in different ways. Any definition helps to understand and explain that concept as better as possible.. Electronic commerce is a set of procedures and technologies that automate the tasks of financial transactions using electronic means. Also, according to some authors, electronic commerce is defined as a new concept, which is being developed and which includes process of buying and selling or exchanging products, services or information via computer networks, including the Internet. Electronic commerce is not limited just to buying and selling, but it also includes all pre-sales and after-sales ongoing activities along the supply chain. Introducing electronic commerce, using the Internet and Web services in business, realizes the way to a completely new type of economy - internet economy.

  12. Mass profile and dynamical status of the z ~ 0.8 galaxy cluster LCDCS 0504

    Science.gov (United States)

    Guennou, L.; Biviano, A.; Adami, C.; Limousin, M.; Lima Neto, G. B.; Mamon, G. A.; Ulmer, M. P.; Gavazzi, R.; Cypriano, E. S.; Durret, F.; Clowe, D.; LeBrun, V.; Allam, S.; Basa, S.; Benoist, C.; Cappi, A.; Halliday, C.; Ilbert, O.; Johnston, D.; Jullo, E.; Just, D.; Kubo, J. M.; Márquez, I.; Marshall, P.; Martinet, N.; Maurogordato, S.; Mazure, A.; Murphy, K. J.; Plana, H.; Rostagni, F.; Russeil, D.; Schirmer, M.; Schrabback, T.; Slezak, E.; Tucker, D.; Zaritsky, D.; Ziegler, B.

    2014-06-01

    Context. Constraints on the mass distribution in high-redshift clusters of galaxies are currently not very strong. Aims: We aim to constrain the mass profile, M(r), and dynamical status of the z ~ 0.8 LCDCS 0504 cluster of galaxies that is characterized by prominent giant gravitational arcs near its center. Methods: Our analysis is based on deep X-ray, optical, and infrared imaging as well as optical spectroscopy, collected with various instruments, which we complemented with archival data. We modeled the mass distribution of the cluster with three different mass density profiles, whose parameters were constrained by the strong lensing features of the inner cluster region, by the X-ray emission from the intracluster medium, and by the kinematics of 71 cluster members. Results: We obtain consistent M(r) determinations from three methods based on kinematics (dispersion-kurtosis, caustics, and MAMPOSSt), out to the cluster virial radius, ≃1.3 Mpc and beyond. The mass profile inferred by the strong lensing analysis in the central cluster region is slightly higher than, but still consistent with, the kinematics estimate. On the other hand, the X-ray based M(r) is significantly lower than the kinematics and strong lensing estimates. Theoretical predictions from ΛCDM cosmology for the concentration-mass relation agree with our observational results, when taking into account the uncertainties in the observational and theoretical estimates. There appears to be a central deficit in the intracluster gas mass fraction compared with nearby clusters. Conclusions: Despite the relaxed appearance of this cluster, the determinations of its mass profile by different probes show substantial discrepancies, the origin of which remains to be determined. The extension of a dynamical analysis similar to that of other clusters of the DAFT/FADA survey with multiwavelength data of sufficient quality will allow shedding light on the possible systematics that affect the determination of mass

  13. Prostate cancer: a comparative study of {sup 11}C-choline PET and MR imaging combined with proton MR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, Takako; Lee, Jin; Takahashi, Nobukazu; Oka, Takashi; Shizukuishi, Kazuya; Inoue, Tomio [Yokohama City University School of Medicine, Department of Radiology, Yokohama (Japan); Uemura, Hiroji; Kubota, Yoshinobu [Yokohama City University School of Medicine, Department of Urology, Kanagawa (Japan); Sasaki, Takeshi [Yokohama City University School of Medicine, Department of Pathology, Kanagawa (Japan); Endou, Hisashi [Yokohama City University School of Medicine, Department of Pharmacy, Kanagawa (Japan)

    2005-07-01

    Prostate cancer is difficult to visualise in its early stages using current imaging technology. The present study aimed to clarify the utility of {sup 11}C-choline PET for localising and evaluating cancer lesions in patients with prostate cancer by conducting a prospective comparison with magnetic resonance (MR) imaging combined with proton MR spectroscopy. PET and MR imaging combined with proton MR spectroscopy were performed in 20 patients with prostate cancer. Correlations among the metabolite ratio of choline + creatine to citrate (Cho+Cr/Ci) on MR spectroscopy, serum PSA and maximum standardised uptake value (SUV{sub max}) of {sup 11}C-choline were assessed. The location of the primary lesion was assessed by the site of SUV{sub max} and the laterality of the highest Cho+Cr/Ci ratio and confirmed by examination of surgical pathology specimens (n=16). PET exhibited a diagnostic sensitivity of 100% (20/20) for primary lesions, while the sensitivities of MR imaging and MR spectroscopy were 60% (12/20) and 65% (13/20), respectively. Weak linear correlations were observed between SUV{sub max} and serum PSA (r=0.52, p<0.05), and between SUV{sub max} and Cho+Cr/Ci ratio (r=0.49, p<0.05). Regarding the localisation of main primary lesions, PET results agreed with pathological findings in 13 patients (81%) ({kappa}=0.59), while MR spectroscopy results were in accordance with pathological findings in eight patients (50%) ({kappa}=0.11). This preliminary study suggests that {sup 11}C-choline PET may provide more accurate information regarding the localisation of main primary prostate cancer lesions than MR imaging/MR spectroscopy. A further clinical study of {sup 11}C-choline PET in a large number of patients suspected of prostate cancer will be necessary to determine the clinical utility of {sup 11}C-choline PET in patients who clinically require biopsy. (orig.)

  14. VME data acquisition system. Interactive software for the acquisition, display and storage of one or two dimensional spectra

    International Nuclear Information System (INIS)

    Petremann, E.

    1989-01-01

    The development and construction of a complete data acquisition system for nuclear physics applications, are described. The system is based on the VME bus and the 16/32 bits microprocessor. The data acquisition system enables the obtention of line spectra, involving one or two parameters, and the simultaneous storage of events in a magnetic tape. The analysis and the description of the data acquisition software, the experimental spectra display and saving on magnetic systems are given. Pascal and Assembler are used. The development of cards, for the standard VME and electronic equipment interfaces, is performed [fr

  15. Generic f(R) theories and classicality of their scalarons

    Energy Technology Data Exchange (ETDEWEB)

    Gannouji, Radouane [Department of Physics, Faculty of Science, Tokyo University of Science, 1-3, Kagurazaka, Shinjuku-ku, Tokyo 162-8601 (Japan); Sami, M., E-mail: samijamia@gmail.com [Kobayashi-Maskawa Institute for the Origin of Particles and the Universe, Nagoya University, Nagoya 464-8602 (Japan); Thongkool, I. [Harish-Chandra Research Institute, Chhatnag Road, Jhusi, Allahabad-211019 (India)

    2012-09-19

    We study quantum stability bound on the mass of scalaron in generic theories of f(R) gravity. We show that in these scenarios, the scalaron mass increases faster with local density of the environment than one-loop quantum correction to it thereby leading to violation of quantum bound on the chameleon mass. The introduction of quadratic curvature corrections in the action are shown to stabilize the model.

  16. Transmission imaging for integrated PET-MR systems.

    Science.gov (United States)

    Bowen, Spencer L; Fuin, Niccolò; Levine, Michael A; Catana, Ciprian

    2016-08-07

    Attenuation correction for PET-MR systems continues to be a challenging problem, particularly for body regions outside the head. The simultaneous acquisition of transmission scan based μ-maps and MR images on integrated PET-MR systems may significantly increase the performance of and offer validation for new MR-based μ-map algorithms. For the Biograph mMR (Siemens Healthcare), however, use of conventional transmission schemes is not practical as the patient table and relatively small diameter scanner bore significantly restrict radioactive source motion and limit source placement. We propose a method for emission-free coincidence transmission imaging on the Biograph mMR. The intended application is not for routine subject imaging, but rather to improve and validate MR-based μ-map algorithms; particularly for patient implant and scanner hardware attenuation correction. In this study we optimized source geometry and assessed the method's performance with Monte Carlo simulations and phantom scans. We utilized a Bayesian reconstruction algorithm, which directly generates μ-map estimates from multiple bed positions, combined with a robust scatter correction method. For simulations with a pelvis phantom a single torus produced peak noise equivalent count rates (34.8 kcps) dramatically larger than a full axial length ring (11.32 kcps) and conventional rotating source configurations. Bias in reconstructed μ-maps for head and pelvis simulations was  ⩽4% for soft tissue and  ⩽11% for bone ROIs. An implementation of the single torus source was filled with (18)F-fluorodeoxyglucose and the proposed method quantified for several test cases alone or in comparison with CT-derived μ-maps. A volume average of 0.095 cm(-1) was recorded for an experimental uniform cylinder phantom scan, while a bias of  <2% was measured for the cortical bone equivalent insert of the multi-compartment phantom. Single torus μ-maps of a hip implant phantom showed significantly

  17. An Examination of Brazil and the United States as Potential Partners in a Joint Supersonic Military Fighter Aircraft Codevelopment and Production Program.

    Science.gov (United States)

    1986-09-01

    Brazilian-American Chamber of Commerce Mr. Frank J. Devine, Executive Director Embraer, Empresa Brasileira De Aeronautica Mr. Salo Roth Vice President...Throughout this study the following assumptions have been made. First, it is assumed that the reader has a basic familiarity with aircraft. Therefore...of the 5 1 weapons acquisition process. Third, the assumption is made that most readers are familiar with U.S. procedures involving the sale of

  18. Effect of MR contrast agents on quantitative accuracy of PET in combined whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lois, Cristina [University of Santiago de Compostela, Department of Particle Physics, Santiago de Compostela (Spain); Health Research Institute of Santiago de Compostela (IDIS), Santiago de Compostela (Spain); Imaging Science Institute, Tuebingen (Germany); Bezrukov, Ilja [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Max Plank Institute for Intelligent Systems, Department of Empirical Inference, Tuebingen (Germany); Schmidt, Holger [Eberhard Karls University, Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens Foundation, Department of Preclinical Imaging and Radiopharmacy, Tuebingen (Germany); Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Schwenzer, Nina; Werner, Matthias K. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Kupferschlaeger, Juergen [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany); Beyer, Thomas [Imaging Science Institute, Tuebingen (Germany); cmi-experts GmbH, Zuerich (Switzerland)

    2012-11-15

    Clinical PET/MR acquisition protocols entail the use of MR contrast agents (MRCA) that could potentially affect PET quantification following MR-based attenuation correction (AC). We assessed the effect of oral and intravenous (IV) MRCA on PET quantification in PET/MR imaging. We employed two MRCA: Lumirem {sup registered} (oral) and Gadovist {sup registered} (IV). First, we determined their reference PET attenuation values using a PET transmission scan (ECAT-EXACT HR+, Siemens) and a CT scan (PET/CT Biograph 16 HI-REZ, Siemens). Second, we evaluated the attenuation of PET signals in the presence of MRCA. Phantoms were filled with clinically relevant concentrations of MRCA in a background of water and {sup 18}F-fluoride, and imaged using a PET/CT scanner (Biograph 16 HI-REZ, Siemens) and a PET/MR scanner (Biograph mMR, Siemens). Third, we investigated the effect of clinically relevant volumes of MRCA on MR-based AC using human pilot data: a patient study employing Gadovist {sup registered} (IV) and a volunteer study employing two different oral MRCA (Lumirem {sup registered} and pineapple juice). MR-based attenuation maps were calculated following Dixon-based fat-water segmentation and an external atlas-based and pattern recognition (AT and PR) algorithm. IV and oral MRCA in clinically relevant concentrations were found to have PET attenuation values similar to those of water. The phantom experiments showed that under clinical conditions IV and oral MRCA did not yield additional attenuation of PET emission signals. Patient scans showed that PET attenuation maps are not biased after the administration of IV MRCA but may be biased, however, after ingestion of iron oxide-based oral MRCA when segmentation-based AC algorithms are used. Alternative AC algorithms, such as AT and PR, or alternative oral contrast agents, such as pineapple juice, can yield unbiased attenuation maps. In clinical PET/MR scenarios MRCA are not expected to lead to markedly increased attenuation

  19. SSR marker analysis on genetic variation of M3 from maize inbred lines 48-2 and R08 after irradiation inducement

    International Nuclear Information System (INIS)

    Li Qi; Shi Haichun; Ke Yongpei; Yuan Jichao; Yu Xuejie

    2011-01-01

    Analyzing the biological effects and the genetic variations of maize mutagenic progenies is important to facilitate effective selections and utilization of the mutants. In this study, the genetic variation of 103 mutagenic progenies of M 3 lines of inbred lines 48-2 and R08 with 60 Co γ-rays inducement were evaluated with SSR molecular markers. The results indicated that, the amplitude of polymorphism information content (PIC) of the 48-2 and R08 M 3 lines ranged 0.307 ∼ 0.948 and 0.108 ∼ 0.955, with an average of 0.762 and 0.701, respectively. The amplitude of genetic diversity indexes (H') ranged 0.552 ∼ 2.830 and 0.254 ∼ 3.309, with an average of 1.830 and 1.777, respectively. The average value of genetic similarity coefficient of the 49 M 3 lines of 48-2 with its check (M673) was 0.8194. However, the average value of genetic similarity coefficient of the M 3 lines of R08 with its check (M487) was 0.8373. Based on the genetic similarity coefficient, inbred lines 48-2, R08 and their 101 M 3 lines were clustered in 7 and 5 populations respectively. This phenomenon indicated that massive genetic variation could appear in progenies due to irradiation. The strengthen of selection and utilization of mutants based on the breeding objectives and in accordance with the feature and regularity on genetic variations of main characteristics of mutant lines in various populations could be enhanced in breeding program, to some extent, which can increase the breeding efficiency of irradiation induced mutation in maize. (authors)

  20. Using Noether symmetries to specify f(R) gravity

    International Nuclear Information System (INIS)

    Paliathanasis, Andronikos

    2013-01-01

    A detailed study of the modified gravity, f(R) models is performed, using the fact that the Noether point symmetries of these models are geometric symmetries of the mini su-perspace of the theory. It is shown that the requirement that the field equations admit Noether point symmetries selects definite models in a self-consistent way. As an application in Cosmology we consider the Friedman -Robertson-Walker spacetime and show that the only cosmological model which is integrable via Noether point symmetries is the (R b − 2Λ) c model, which generalizes the Lambda Cosmology. Furthermore using the corresponding Noether integrals we compute the analytic form of the main cosmological functions

  1. A preliminary study of murine walker-256 tumor hypoxia detected by blood oxygen level dependent-MR

    International Nuclear Information System (INIS)

    Zhang Shengjian; Mao Jian; Wu Bin; Peng Weijun

    2013-01-01

    Objective: To establish Walker-256 transplantation tumor model in SD Rats. To study of R_2"* signal changes on murine Walker-256 tumor after inhaling Carbogen by blood oxygen level dependent (BOLD)-MR, and to explore the feasibility of BOLD-MRI on detecting tumor hypoxia. Methods: Walker-256 tumor cell implanted subcutaneously in right lower abdomen of 95 female SD rats. MR was performed on the tumor-forming rats when the maximum diameter of tumor reached 1-3 cm, using a 3.0 T MR scanner equipped with a 3 inch animal surface coil. BOLD-MRI was done by using a multiecho SPGR sequence during inhaling air and at 10 minute after inhaling Carbogen, respectively. All images were transferred to GE ADW 4.3 workstation, then a baseline R_2"* (R_2"* a) and R_2"* (R_2"* b) after inhaling Carbogen of tumor was calculated using R_2 Star analysis software and ΔR_2"* was calculated through ΔR_2"* = R_2"* b -R_2"* a", meanwhile the volume of tumor were calculated as well. The difference of R_2"* signal pre and post-inhaling of Carbogen was compared with a paired t test, Pearson correlation was calculated between R_2"* a, ΔR_2"* and the volume of tumor, respectively. The correlation between ΔR_2"* and R_2"* a was also assessed by Pearson correlation. Results: Sixty-eight of ninety-five female SD rats formed the tumor (71.6%). The volume of tumor was from 352 to 13 173 mm"3. Mean ΔR_2"* decreased significantly (-2.26 ± 3.90) s"-"1 from (41.18 ± 22.29) s"-"1 during breathing air to (38.91 ± 21.35) s"-"1 10 min after inhaling Carbogen (t = 4.01, P 0.05). Conclusions: BOLD-MRI can detect the R_2"* signal change of murine Walker-256 tumor pre-and post-inhaling of Carbogen. The R_2"* signal showed significant decrease after inhaling Carbogen, however, the individual variation was remarkable. (authors)

  2. Event-related potentials elicited by social commerce and electronic-commerce reviews.

    Science.gov (United States)

    Bai, Yan; Yao, Zhong; Cong, Fengyu; Zhang, Linlin

    2015-12-01

    There is an increasing interest regarding the use of electroencephalography (EEG) in social commerce and electronic commerce (e-commerce) research. There are several reviews in the field of social commerce or e-commerce; these have great potential value and mining them is fundamental and significant. To our knowledge, EEG is rarely applied to study these. In this study, we examined the neural correlates of social commerce reviews (SCRs) and e-commerce reviews (ECRs) by using them as stimuli to evoke event-related potentials. All SCRs were from friends through a social media platform, whereas ECRs were from strangers through an e-commerce platform. The experimental design was similar to that of a priming paradigm, and included 40 pairs of stimuli consisting of product information (prime stimulus) and reviews (target stimulus). The results showed that the P300 component was successfully evoked by SCR and ECR stimuli. Moreover, the P300 components elicited by SCRs had higher amplitudes than those elicited by ECRs. These findings indicate that participants paid more attention to SCRs than to ECRs. In addition, the associations between neural responses and reviews in social commerce have the potential to assist companies in studying consumer behaviors, thus permitting them to enhance their social commerce strategies.

  3. R-R interval variations influence the degree of mitral regurgitation in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Reimann, M. J.; Moller, J. E.; Haggstrom, J.

    2014-01-01

    of congestive heart failure due to MMVD. The severity of MR was evaluated in apical four-chamber view using colour Doppler flow mapping (maximum % of the left atrium area) and colour Doppler M-mode (duration in ms). The influence of the ratio between present and preceding R-R interval on MR severity......Mitral regurgitation (MR) due to myxomatous mitral valve disease (MMVD) is a frequent finding in Cavalier King Charles Spaniels (CKCSs). Sinus arrhythmia and atrial premature complexes leading to R-R interval variations occur in dogs. The aim of the study was to evaluate whether the duration...... of the RR interval immediately influences the degree of MR assessed by echocardiography in dogs. Clinical examination including echocardiography was performed in 103 privately-owned dogs: 16 control Beagles, 70 CKCSs with different degree of MR and 17 dogs of different breeds with clinical signs...

  4. 77 FR 58410 - Commerce in Explosives; List of Explosive Materials (2012R-10T)

    Science.gov (United States)

    2012-09-20

    ... sensitive slurry and water gel explosives. Blasting caps. Blasting gelatin. Blasting powder. BTNEC [bis.... Esters of nitro-substituted alcohols. Ethyl-tetryl. Explosive conitrates. Explosive gelatins. Explosive.... Fulminate of silver. Fulminating gold. Fulminating mercury. Fulminating platinum. Fulminating silver. G...

  5. 75 FR 43561 - Investigations Regarding Certifications of Eligibility To Apply for Worker Adjustment Assistance

    Science.gov (United States)

    2010-07-26

    ... Sunnyvale, CA 07/07/10 07/01/10 (Company). 74346 Warner Brothers Burbank, CA 07/07/10 07/01/10 Entertainment...). 74356 Industrial Technologies Missoula, MT 07/08/10 07/02/10 Corporation (Company). 74357 Cinram... (Workers). 74367 Sensata Technologies Attleboro, MA 07/09/10 06/30/10 (Workers). [FR Doc. 2010-18182 Filed...

  6. Noun Imageability Facilitates the Acquisition of Plurals: Survival Analysis of Plural Emergence in Children

    Czech Academy of Sciences Publication Activity Database

    Smolík, Filip

    2014-01-01

    Roč. 43, č. 4 (2014), s. 335-350 ISSN 0090-6905 R&D Projects: GA ČR GAP407/10/2047 Institutional support: RVO:68081740 Keywords : Language acquisition * Imageability * Morphology * Acquisition of inflections * Semantic generality Subject RIV: AN - Psychology Impact factor: 0.633, year: 2014

  7. MO-FG-BRA-09: Quantification of Nanoparticle Heating and Concentration for MR-Guided Laser Interstitial Thermal Therapy

    International Nuclear Information System (INIS)

    MacLellan, CJ; Melancon, M; Fuentes, D; Stafford, RJ; Salatan, F; Yang, Q; Hwang, KP

    2015-01-01

    Purpose: Nanoparticle Mediated Laser Interstitial Thermal Therapy (npLITT) is a technique that utilizes tumor localized optically activated nanoparticles to increase the conformality of laser ablation procedures. Temperatures in these procedures are dependent on the particle concentration which generally cannot be measured noninvasively prior to therapy. In this work we attempt to quantify particle concentration in vivo by estimating the increase in R2* relaxation induced by bifunctional magnetic resonance (MR)-visible gold-based nanoparticles (SPIO@Au) and relate it to the temperature increase observed during real time MR temperature imaging (MRTI) of laser ablation. Methods: SPIO@Au nanoparticles (90nm) were synthesized containing a silica-iron core (for MR visibility via R2*) and gold shell (for near-infrared absorption). High resolution R2* maps were acquired before and after injecting four different particle concentrations (saline,1e10, 5e10, and 10e10 particles/mL) into HN5 flank xenografts. Tumors were monitored using MRTI during treatment with an interstitial fiber. (1 watt, 808 nm, 3 minutes) Results: The maximum temperature within the tumors increased linearly with concentration of injected particles, reaching 34.0, 37.6, 45.8, and 55.4 "0C for saline, 1e10, 5e10 and 10e10 particles/mL injections, respectively (R2=.994). The highest temperatures occur at the injection site rather than the fiber, confirming that SPIO@Au nanoparticles are the primary absorber. The differences between the median R2* measured at the injection site and the rest of the tumor were −6, 134, 111, 156 s-1 for the saline,1e10,5e10 and 10e10 particles/mL injections, respectively. This R2* change is consistent with the measured relaxivity for the 1e10 particles/mL injection but does not maintain linearity at higher concentrations. Conclusion: Bifunctional SPIO@Au nanoparticles are a promising technology for providing noninvasive estimates of particle concentration via MRI and

  8. 76 FR 61075 - Foreign-Trade Zone 127-Columbia, SC; Application for Reorganization/Expansion Under Alternative...

    Science.gov (United States)

    2011-10-03

    ... Board on July 2, 1986 (Board Order 333, 51 FR 25075, 7/10/86). The current zone project includes the... DEPARTMENT OF COMMERCE Foreign-Trade Zones Board [Docket 57-2011] Foreign-Trade Zone 127--Columbia... submitted to the Foreign-Trade Zones (FTZ) Board (the Board) by the Richland-Lexington Airport District...

  9. miR-10 in development and cancer

    DEFF Research Database (Denmark)

    Lund, Anders Henrik

    2010-01-01

    The microRNA (miRNA) miR-10 family has attracted attention because of its conservation and the position of the miR-10 genes within the Hox clusters of developmental regulators. In several species, miR-10 is coexpressed with a set of Hox genes and has been found to regulate the translation of Hox ...... function to the miRNA repertoire.Cell Death and Differentiation advance online publication, 22 May 2009; doi:10.1038/cdd.2009.58....

  10. Chamber of Commerce reception for Dr. Lucas

    Science.gov (United States)

    1986-01-01

    Dr. William R. Lucas, Marshall's fourth Center Director (1974-1986), delivers a speech in front of a picture of the lunar landscape with Earth looming in the background while attending a Huntsville Chamber of Commerce reception honoring his achievements as Director of Marshall Space Flight Center (MSFC).

  11. Measurement of skeletal muscle area: Comparison of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sinelnikov, Andrey, E-mail: sinelnikovas@upmc.edu [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Qu, Chuanxing [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Fetzer, David T. [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Pelletier, Jean-Sébastien [Department of Surgery, Jewish General Hospital, McGill University, Montreal, Quebec (Canada); Dunn, Michael A. [Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Tsung, Allan [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Furlan, Alessandro [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2016-10-15

    Objective: To investigate the intra- and inter-observer agreement and correlation between CT and MR measurements of skeletal muscle area (SMA) in the abdomen. Methods: CT and MR images from twelve patients were analyzed by two blinded observers using segmentation software (MITK-3M3, Mint Medical and Slice-O-Matic, Tomovision) to quantify SMA. MR images included T1w “in-phase”, T1w “out-of-phase”, and T2w sequences. Inter- and intra-observer agreement was assessed using the intraclass correlation coefficient (ICC). Pearson correlation coefficient (r) was used to correlate measurements obtained on MR with CT. CT and MR measurements were compared with Bland-Altman plots. Results: Intra- and inter-observer agreement for SMA was high for CT and MR. For MR, the measurements on T2w images showed the highest inter-observer agreement (ICC = 0.96). CT SMA correlated closely with MR, with T2w images showing the highest correlation (r = 0.98; P < 0.01). Bland-Altman plots showed a 1.7%–3.9% bias between CT and MR measurements, lowest for T2w images. Conclusions: MR SMA measurements are reproducible and correlate closely with CT. The T2w sequence is recommended to quantify SMA on MR images.

  12. Thick brane in f(R) gravity with Palatini dynamics

    International Nuclear Information System (INIS)

    Bazeia, D.; Losano, L.; Menezes, R.; Olmo, Gonzalo J.; Rubiera-Garcia, D.

    2015-01-01

    This work deals with modified gravity in five-dimensional space-time. We study a thick Palatini f(R) brane, that is, a braneworld scenario described by an anti-de Sitter warped geometry with a single extra dimension of infinite extent, sourced by a real scalar field under the Palatini approach, where the metric and the connection are regarded as independent degrees of freedom. We consider a first-order framework which we use to provide exact solutions for the scalar field and warp factor. We also investigate a perturbative scenario such that the Palatini approach is implemented through a Lagrangian f(R)=R+ϵR n , where the small parameter ϵ controls the deviation from the standard thick brane case. In both cases it is found that the warp factor tends to localize the extra dimension due to the nonlinear corrections

  13. Thick brane in f(R) gravity with Palatini dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Bazeia, D., E-mail: bazeia@fisica.ufpb.br; Losano, L., E-mail: losano@fisica.ufpb.br [Departamento de Física, Universidade Federal da Paraíba, 58051-900, João Pessoa, PB (Brazil); Menezes, R., E-mail: rmenezes@dce.ufpb.br [Departamento de Ciências Exatas, Universidade Federal da Paraíba, 58297-000, Rio Tinto, PB (Brazil); Departamento de Física, Universidade Federal de Campina Grande, 58109-970, Campina Grande, PB (Brazil); Olmo, Gonzalo J., E-mail: gonzalo.olmo@csic.es [Departamento de Física, Universidade Federal da Paraíba, 58051-900, João Pessoa, PB (Brazil); Departamento de Física Teórica, IFIC, Centro Mixto Universidad de Valencia-CSIC, Universidad de Valencia, 46100, Burjassot, Valencia (Spain); Rubiera-Garcia, D., E-mail: drgarcia@fc.ul.pt [Departamento de Física, Universidade Federal da Paraíba, 58051-900, João Pessoa, PB (Brazil); Faculdade de Ciências, Instituto de Astrofísica e Ciências do Espaço, Universidade de Lisboa, Campo Grande, 1749-016, Lisbon (Portugal); Department of Physics, Center for Field Theory and Particle Physics, Fudan University, 220 Handan Road, 200433, Shanghai (China)

    2015-11-30

    This work deals with modified gravity in five-dimensional space-time. We study a thick Palatini f(R) brane, that is, a braneworld scenario described by an anti-de Sitter warped geometry with a single extra dimension of infinite extent, sourced by a real scalar field under the Palatini approach, where the metric and the connection are regarded as independent degrees of freedom. We consider a first-order framework which we use to provide exact solutions for the scalar field and warp factor. We also investigate a perturbative scenario such that the Palatini approach is implemented through a Lagrangian f(R)=R+ϵR{sup n}, where the small parameter ϵ controls the deviation from the standard thick brane case. In both cases it is found that the warp factor tends to localize the extra dimension due to the nonlinear corrections.

  14. WooCommerce cookbook

    CERN Document Server

    Rauland, Patrick

    2015-01-01

    If you have ever built or managed a WordPress site and want to add e-commerce functionality into your site, WooCommerce and this book are perfect for you. Learning how to use WooCommerce through this series of recipes will give you a solid platform to add any future e-commerce needs.

  15. 41 CFR 102-73.10 - What is the basic real estate acquisition policy?

    Science.gov (United States)

    2010-07-01

    ... ESTATE ACQUISITION General Provisions § 102-73.10 What is the basic real estate acquisition policy? When... real estate and related services in an efficient and cost effective manner. ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What is the basic real...

  16. An Electronic Commerce Strategy for MTMC’s Guaranteed Traffic Program

    Science.gov (United States)

    1992-10-01

    AD-A264 299 SELECTE October 1992 S MAY1 4 1993U C An Electronic Commerce Strategy for MTMC’s Guaranteed Traffic Program MT901R I N1. Augustine...NUMBERS An Electronic Commerce Strategy for MTMC’s Guaranteed Traffic Program C MDA903-85-C -0139 M DA903-90-C-0006 PE 0902198D 6. AUTHOR(S) M...239-1L 299-01 LMI Executive Summary AN ELECTRONIC COMMERCE STRATEGY FOR MTMC’S GUARANTEED TRAFFIC PROGRAM In 1979, the Military Traffic Management

  17. 2007 MrSID Image of St. John Utilized to derive Benthic Habitat Maps (18064_c6_ne.sid)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This MrSID (.sid) file is an orthophoto mosaic from a collection of GeoTIFF format natural color and false color infrared orthophotos covering the islands of Puerto...

  18. 2007 MrSID Image of St. John Utilized to derive Benthic Habitat Maps (18064_c7_se.sid)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This MrSID (.sid) file is an orthophoto mosaic from a collection of GeoTIFF format natural color and false color infrared orthophotos covering the islands of Puerto...

  19. 2007 MrSID Image of St. John Utilized to derive Benthic Habitat Maps (18064_c7_nw.sid)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This MrSID (.sid) file is an orthophoto mosaic from a collection of GeoTIFF format natural color and false color infrared orthophotos covering the islands of Puerto...

  20. 2007 MrSID Image of St. John Utilized to derive Benthic Habitat Maps (18064_c6_sw.sid)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This MrSID (.sid) file is an orthophoto mosaic from a collection of GeoTIFF format natural color and false color infrared orthophotos covering the islands of Puerto...

  1. 2007 MrSID Image of St. John Utilized to derive Benthic Habitat Maps (18064_c7_ne.sid)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This MrSID (.sid) file is an orthophoto mosaic from a collection of GeoTIFF format natural color and false color infrared orthophotos covering the islands of Puerto...

  2. 15 CFR 19.14 - How will Commerce entities report Commerce debts to credit bureaus?

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false How will Commerce entities report Commerce debts to credit bureaus? 19.14 Section 19.14 Commerce and Foreign Trade Office of the Secretary of Commerce COMMERCE DEBT COLLECTION Procedures To Collect Commerce Debts § 19.14 How will Commerce entities...

  3. Proton MR spectroscopic features of the human liver: in-vivo application to the normal condition

    International Nuclear Information System (INIS)

    Cho, Soon Gu; Kim, Mi Young; Kim, Young Soo; Choi, Won; Shin, Seok Hwan; Ok, Chul Soo; Suh, Chang Hae

    1999-01-01

    To determine the feasibility of MR spectroscopy in the living human liver, and to evaluate the corresponding proton MR spectroscopic features. In fifteen normal volunteers with neither previous nor present liver disease, the proton MR spectroscopic findings were reviewed. Twelve subjects were male and three were female ; they were aged between 28 and 32 (mean, 30) years. MR spectroscopy involved the use of a 1.5T GE Signa Horizon system with body coil(GE Medical System, Milwaukee, U.S.A). We used STEAM (Stimulated Echo-Acquisition Mode) with 3000/30 msec of TR/TE for signal acquisition, and the prone position without respiratory interruption. Mean and standard deviation of the ratios of glutamate+glutamine/lipids, phosphomonoesters/lipids, and glycogen+glucose/lipids were calculated from the area of their peaks. The proton MR spectroscopic findings of normal human livers showed four distinctive peaks, i.e. lipids, glutamate and glutamine complex, phosphomonoesters, and glycogen and glucose complex. The mean and standard deviation of the ratios of glutamate+glutamine/lipids, phosphomonoesters/lipids, and glycogen+glucose/lipids were 0.02±0.01, 0.01±0.01, and 0.04±0.03, respectively. In living normal human livers, MR spectroscopy can be successfully applied. When applied to a liver whose condition is pathologic, the findings can be used as a standard

  4. E-Commerce

    OpenAIRE

    Vancauteren, Mark

    2011-01-01

    International e-commerce, which involves cross-border transactions over the internet, shows every sign of continuing to expand rapidly. The potential savings of transaction costs from e-commerce are substantial. The most important cost-saving aspect of e-commerce is the reduction in travel, administration, communication and search costs. One consequence of such cost advantages is that many small cross-border transactions have now become economic. In addi...

  5. MR fingerprinting reconstruction with Kalman filter.

    Science.gov (United States)

    Zhang, Xiaodi; Zhou, Zechen; Chen, Shiyang; Chen, Shuo; Li, Rui; Hu, Xiaoping

    2017-09-01

    Magnetic resonance fingerprinting (MR fingerprinting or MRF) is a newly introduced quantitative magnetic resonance imaging technique, which enables simultaneous multi-parameter mapping in a single acquisition with improved time efficiency. The current MRF reconstruction method is based on dictionary matching, which may be limited by the discrete and finite nature of the dictionary and the computational cost associated with dictionary construction, storage and matching. In this paper, we describe a reconstruction method based on Kalman filter for MRF, which avoids the use of dictionary to obtain continuous MR parameter measurements. With this Kalman filter framework, the Bloch equation of inversion-recovery balanced steady state free-precession (IR-bSSFP) MRF sequence was derived to predict signal evolution, and acquired signal was entered to update the prediction. The algorithm can gradually estimate the accurate MR parameters during the recursive calculation. Single pixel and numeric brain phantom simulation were implemented with Kalman filter and the results were compared with those from dictionary matching reconstruction algorithm to demonstrate the feasibility and assess the performance of Kalman filter algorithm. The results demonstrated that Kalman filter algorithm is applicable for MRF reconstruction, eliminating the need for a pre-define dictionary and obtaining continuous MR parameter in contrast to the dictionary matching algorithm. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. SU-E-J-217: Multiparametric MR Imaging of Cranial Tumors On a Dedicated 1.0T MR Simulator Prior to Stereotactic Radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Glide-Hurst, C; Liu, M; Hearshen, D; Brown, S; Siddiqui, S; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2015-06-15

    Purpose: Quantitative magnetic resonance imaging (MRI) of cranial lesions prior to stereotactic radiosurgery (SRS) may improve treatment planning and provide potential prognostic value. The practicality and logistics of acquiring advanced multiparametric MRI sequences to measure vascular and cellular properties of cerebral tumors are explored on a 1.0 Tesla MR Simulator. Methods: MR simulation was performed immediately following routine CT simulation on a 1T MR Simulator. MR sequences used were in the order they were performed: T2-Weighted Turbo Spin Echo (T2W-TSE), T2 FLAIR, Diffusion-weighted (DWI, b = 0, 800 to generate an apparent diffusion coefficient (ADC) map), 3D T1-Weighted Fast Field Echo (T1W-FFE), Dynamic Contrast Enhanced (DCE) and Post Gadolinium Contrast Enhanced 3D T1W-FFE images. T1 pre-contrast values was generated by acquiring six different flip angles. The arterial input function was derived from arterial pixels in the perfusion images selected manually. The extended Tofts model was used to generate the permeability maps. Routine MRI scans took about 30 minutes to complete; the additional scans added 12 minutes. Results: To date, seven patients with cerebral tumors have been imaged and tumor physiology characterized. For example, on a glioblastoma patient, the volume contoured on T1 Gd images, ADC map and the pharmacokinetic map (Ktrans) were 1.9, 1.4, and 1.5 cc respectively with strong spatial correlation. The mean ADC value of the entire volume was 1141 μm2/s while the value in the white matter was 811 μm2/s. The mean value of Ktrans was 0.02 min-1 in the tumor volume and 0.00 in the normal white matter. Conclusion: Our initial results suggest that multiparametric MRI sequences may provide a more quantitative evaluation of vascular and tumor properties. Implementing functional imaging during MR-SIM may be particularly beneficial in assessing tumor extent, differentiating radiation necrosis from tumor recurrence, and establishing reliable

  7. MR angiography of the cerebral vessels with inflow-increased visualization by overcontiguous imaging and advanced processing

    International Nuclear Information System (INIS)

    McLachian, S.; Simon, H.E.; de Graaf, R.; Ho, A.M.; Ruccio, W.J.; Steidley, J.W.; Pradhan, R.B.

    1989-01-01

    The purpose of this study was to increase the visualization of cerebral vessels with MR angiography by using an inflow technique from transverse sections. Difficulties with visualization include the tortuous nature of the vessels and slow blood flow. The MR method is a transverse two-dimensional multiple single-section sequence with a velocity-compensated gradient echo and presaturation. A S15 imager with 10-mTm gradients and a prototype angiographic package is used. Overcontiguous acquisition yields smaller effective center-to-center sections. Interpolation is used to generate interleaved plane projections. A combination of image parameter swill reduce the level of the stationary tissue relative to the flowing blood. For vessels that are not perpendicular to the section, overlapping the sections by 25%--33% is shown to reduce the staircase appearance without affecting the apparent size of the vessels. Interpolation of the MR images will further reduce this artifact, giving the vessels a smooth structure. MR angiography of the brain performed with an inflow technique allows the visualization of vessels in the brain even if the vessels follow tortuous paths. Presaturation and user-defined regions of interest can be used for ease of interpretation

  8. MR-based attenuation correction for cardiac FDG PET on a hybrid PET/MRI scanner: comparison with standard CT attenuation correction

    Energy Technology Data Exchange (ETDEWEB)

    Vontobel, Jan; Liga, Riccardo; Possner, Mathias; Clerc, Olivier F.; Mikulicic, Fran; Veit-Haibach, Patrick; Voert, Edwin E.G.W. ter; Fuchs, Tobias A.; Stehli, Julia; Pazhenkottil, Aju P.; Benz, Dominik C.; Graeni, Christoph; Gaemperli, Oliver; Herzog, Bernhard; Buechel, Ronny R.; Kaufmann, Philipp A. [University Hospital Zurich, Department of Nuclear Medicine, Zurich (Switzerland)

    2015-09-15

    The aim of this study was to evaluate the feasibility of attenuation correction (AC) for cardiac {sup 18}F-labelled fluorodeoxyglucose (FDG) positron emission tomography (PET) using MR-based attenuation maps. We included 23 patients with no known cardiac history undergoing whole-body FDG PET/CT imaging for oncological indications on a PET/CT scanner using time-of-flight (TOF) and subsequent whole-body PET/MR imaging on an investigational hybrid PET/MRI scanner. Data sets from PET/MRI (with and without TOF) were reconstructed using MR AC and semi-quantitative segmental (20-segment model) myocardial tracer uptake (per cent of maximum) and compared to PET/CT which was reconstructed using CT AC and served as standard of reference. Excellent correlations were found for regional uptake values between PET/CT and PET/MRI with TOF (n = 460 segments in 23 patients; r = 0.913; p < 0.0001) with narrow Bland-Altman limits of agreement (-8.5 to +12.6 %). Correlation coefficients were slightly lower between PET/CT and PET/MRI without TOF (n = 460 segments in 23 patients; r = 0.851; p < 0.0001) with broader Bland-Altman limits of agreement (-12.5 to +15.0 %). PET/MRI with and without TOF showed minimal underestimation of tracer uptake (-2.08 and -1.29 %, respectively), compared to PET/CT. Relative myocardial FDG uptake obtained from MR-based attenuation corrected FDG PET is highly comparable to standard CT-based attenuation corrected FDG PET, suggesting interchangeability of both AC techniques. (orig.)

  9. Investigating the little rip and other future singularities of the universe, and validity of the second law of thermodynamics in F(R theory

    Directory of Open Access Journals (Sweden)

    M Aghaei Abchouyeh

    2015-01-01

    Full Text Available The future singularities are possible in a universe that is described by F(R theory. In previous studies the occurrence of the singularities in F(R theory have been considered by using a special function for the Hubble parameter and calculating the F(R function for each of the singularities. Using the specified Hubble parameter causes some difficulties in the study of the second law of thermodynamics. In this paper by using the scale factor, the behavior of F(R function near each type of the singularities is considered. We can check the validity of the second law of thermodynamics near the singularities. At first we study the Little Rip and then the other types of singularities are considered. The results show that the second law of thermodynamics is satisfied near the singularity type (I with some special conditions and is violated with some other conditions. it is satisfied near the Little Rip, type (II, (III and (IV singularities

  10. Respiratory and cardiac motion correction in dual gated PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fayad, Hadi; Monnier, Florian [LaTIM, INSERM, UMR 1101, Brest (France); Odille, Freedy; Felblinger, Jacques [INSERM U947, University of Nancy, Nancy (France); Lamare, Frederic [INCIA, UMR5287, CNRS, CHU Bordeaux, Bordeaux (France); Visvikis, Dimitris [LaTIM, INSERM, UMR 1101, Brest (France)

    2015-05-18

    Respiratory and cardiac motion in PET/MR imaging leads to reduced quantitative and qualitative image accuracy. Correction methodologies involve the use of double gated acquisitions which lead to low signal-to-noise ratio (SNR) and to issues concerning the combination of cardiac and respiratory frames. The objective of this work is to use a generalized reconstruction by inversion of coupled systems (GRICS) approach, previously used for PET/MR respiratory motion correction, combined with a cardiac phase signal and a reconstruction incorporated PET motion correction approach in order to reconstruct motion free images from dual gated PET acquisitions. The GRICS method consists of formulating parallel MRI in the presence of patient motion as a coupled inverse problem. Its resolution, using a fixed-point method, allows the reconstructed image to be improved using a motion model constructed from the raw MR data and two respiratory belts. GRICS obtained respiratory displacements are interpolated using the cardiac phase derived from an ECG to model simultaneous cardiac and respiratory motion. Three different volunteer datasets (4DMR acquisitions) were used for evaluation. GATE was used to simulate 4DPET datasets corresponding to the acquired 4DMR images. Simulated data were subsequently binned using 16 cardiac phases (M1) vs diastole only (M2), in combination with 8 respiratory amplitude gates. Respiratory and cardiac motion corrected PET images using either M1 or M2 were compared to respiratory only corrected images and evaluated in terms of SNR and contrast improvement. Significant visual improvements were obtained when correcting simultaneously for respiratory and cardiac motion (using 16 cardiac phase or diastole only) compared to respiratory motion only compensation. Results were confirmed by an associated increased SNR and contrast. Results indicate that using GRICS is an efficient tool for respiratory and cardiac motion correction in dual gated PET/MR imaging.

  11. MR assessment of fetal pulmonary hypoplasia

    Energy Technology Data Exchange (ETDEWEB)

    Kuwashima, Shigeko; Kohno, Atsushi; Saiki, Natoru; Iimura, Fumitoshi; Kohno, Tatsuo; Hashimoto, Teisuke; Fujioka, Mutsuhisa [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-08-01

    The purpose of this study is to evaluate pulmonary hypoplasia of the fetus using MRI. The subjects consisted of 36 fetuses (18 to 40 weeks' gestation). All fetuses or mothers had major anomalies diagnosed on fetal ultrasonography. MR imaging was performed with a 1.5-T magnet and HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequence. MR images were evaluated with special attention to the intensity of the lung. A diagnosis of pulmonary hypoplasia was based on the clinical, surgical, and autopsy findings. All fetuses with normal pulmonary development showed high intensity in the lung, while all fetuses with pulmonary hypoplasia showed a low intensity in the lung, obscured pulmonary vessels and a small thorax. There was a close correlation between the lung intensity and pulmonary growth. MR assessment of lung intensity may facilitate the diagnosis of pulmonary hypoplasia, particularly after 26 weeks' gestation. Some of the normally developing lung showed a low intensity from 20 to 24 weeks of gestational age. The change to normal lung intensity may occur during this period. (author)

  12. PET motion correction in context of integrated PET/MR: Current techniques, limitations, and future projections.

    Science.gov (United States)

    Gillman, Ashley; Smith, Jye; Thomas, Paul; Rose, Stephen; Dowson, Nicholas

    2017-12-01

    Patient motion is an important consideration in modern PET image reconstruction. Advances in PET technology mean motion has an increasingly important influence on resulting image quality. Motion-induced artifacts can have adverse effects on clinical outcomes, including missed diagnoses and oversized radiotherapy treatment volumes. This review aims to summarize the wide variety of motion correction techniques available in PET and combined PET/CT and PET/MR, with a focus on the latter. A general framework for the motion correction of PET images is presented, consisting of acquisition, modeling, and correction stages. Methods for measuring, modeling, and correcting motion and associated artifacts, both in literature and commercially available, are presented, and their relative merits are contrasted. Identified limitations of current methods include modeling of aperiodic and/or unpredictable motion, attaining adequate temporal resolution for motion correction in dynamic kinetic modeling acquisitions, and maintaining availability of the MR in PET/MR scans for diagnostic acquisitions. Finally, avenues for future investigation are discussed, with a focus on improvements that could improve PET image quality, and that are practical in the clinical environment. © 2017 American Association of Physicists in Medicine.

  13. Electronic Commerce

    OpenAIRE

    Slavko Đerić

    2016-01-01

    Electronic commerce can be defined in different ways. Any definition helps to understand and explain that concept as better as possible.. Electronic commerce is a set of procedures and technologies that automate the tasks of financial transactions using electronic means. Also, according to some authors, electronic commerce is defined as a new concept, which is being developed and which includes process of buying and selling or exchanging products, services or information via computer networks...

  14. MR thermometry for laser-induced thermotherapy at 1.5 tesla; MR-Thermometrie bei 1,5 Tesla zur thermischen Ablation mittels laserinduzierter Thermotherapie

    Energy Technology Data Exchange (ETDEWEB)

    Meister, D.; Huebner, F.; Mack, M.; Vogl, T.J. [Frankfurt Univ. (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2007-05-15

    Purpose: Evaluation of thermometry with fast MR sequences for laser-induced interstitial laser therapy (LITT) and verification of the thermometric results with a fiber-optic thermometer. Method and Materials: In vitro experiments were conducted using an agarose gel mixture and pig liver lobes. MR-guided LITT was performed using a laser power between 3 and 15?watts. Thermometry was performed using longitudinal relaxation time T1 and proton resonance frequency shift (PRF) methods under acquisition of amplitude and phase shift images. PRF was measured with a fast spoiled GRE sequence. Four different sequences were used for T1 thermometry: gradient echo (GE), TrueFISP (TRUFI), Saturation Recovery Turbo-FLASH (SRTF) and Inversion Recovery Turbo-FLASH (IRTF) sequences. The temperature was controlled using a fiber-optic Luxtron device and correlated with the MR temperature. The range of applied and monitored temperatures exceeded 80 degrees Celsius. Results: The temperature dependence showed a good linear relationship up to 60 degrees Celsius. Calibration experiments for the T1 method delivered coefficients of determination from 0.977 to 0.997 for agarose and from 0.958 to 0.995 for the pig liver samples. The IRTF sequence had the highest temperature sensitivity (agarose 0.99, liver 1.19). During LITT the TRUE-FISP sequence exhibited a strong nonlinear relationship. R{sup 2} of this sequence was 0.809 in the agarose experiments. The average temperature errors when heated up to 80 degrees Celsius were 3.86 - 11.38 degrees Celsius for Agarose gel and 5.7 - 12.16 degrees Celsius for the liver tissue. SRTF and IRTF sequences exhibited the most linear relationship with temperature but were more dependent on tissue differences. (orig.)

  15. AFSC/RACE/EcoFOCI: 2010 BEST and BSIERP Study 1WE10/WE10-08

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ecosystem & Fisheries-Oceanography Coordinated Investigations (Eco-FOCI) is an effort by National Oceanic and Atmospheric Administration (NOAA) and associated...

  16. MR imaging of rotator cuff tears

    International Nuclear Information System (INIS)

    Kumagai, Hideo

    1992-01-01

    A total of 115 patients with clinical symptoms and signs suggesting rotator cuff tears underwent MR imaging with a 1.5-Tesla system. The body coil was used as the receiver coil in 24 patients and a single 10 cm surface coil in 91. Arthrography or MR imaging with intra-articular Gd-DTPA (MR arthrography) was performed in 95 of the 115. T2-weighted images with the body coil showed high signal intensity lesions in rotator cuffs in only seven of the 10 patients who had tears demonstrated by arthrography or MR arthrography. On the other hand, T2-weighted images with the surface coil demonstrated high signal intensity lesions in cuffs in all 27 patients who were diagnosed to have tears by arthrography or MR arthrography. In 12 patietns, T2-wighted images with the surface coil showed high signal intensity lesions in cuffs, while arthrography and MR arthrography did not show tears. Surgery was performed in four of the 12 patients and partial tears were confirmed. A single 10 cm surface coil, 3 mm slice thickness and 2.5 second repetition time seem to account for the fine visualization of cuff tears by the T2-weighted images. These results suggest that T2-weighted images obtained with the surface coil are superior to arthrography and MR arthrography. (author)

  17. Interview. The story of Advanced BioHealing: commercializing bioengineered tissue products. Mr Tozer speaks to Emily Culme-Seymour, Assistant Commissioning Editor.

    Science.gov (United States)

    Tozer, Dean

    2011-03-01

    Dean Tozer is Senior Vice President at Advanced BioHealing, Inc. (ABH), overseeing marketing, corporate development, government affairs, product development, various regulatory functions and international expansion. After completing his Bachelor of Commerce from Saint Mary's University in Halifax, Canada, Mr Tozer spent 10 years in the global pharmaceutical industry, primarily with G.D. Searle (a division of Monsanto) where he had a wide variety of roles in Global Marketing, Sales, Business Redesign, and Accounting and Finance. Mr Tozer then worked as a consultant to the biopharmaceutical industry, assisting start-up organizations in developing commercial strategies for both pharmaceutical products and biomedical devices, prior to joining ABH in March 2006 as Vice President of Marketing & Corporate Development. In addition to his leadership role at ABH, Mr Tozer currently serves as an officer and board member for the Alliance for Regenerative Medicine, a Washington DC-based organization formed to advance regenerative medicine by representing and supporting the community of companies, academic research institutions, patient advocacy groups, foundations, and other organizations before the Congress, federal agencies and the general public.

  18. Message from Mr. R.A. Al-Kital, Commissioner of the Iraqi Atomic Energy Commission, received by the Director General on 23 October 1985

    International Nuclear Information System (INIS)

    1985-10-01

    The document reproduces the message from Mr. R.A. Al-Kital, Commissioner of the Iraqi Atomic Energy Commission received by the Director General of the IAEA on 23 October 1985 related to the Israeli attack against the Iraqi nuclear installations

  19. MR in phenylketonuria-related brain lesions

    Czech Academy of Sciences Publication Activity Database

    Dezortová, M.; Hájek, M.; Tintěra, J.; Hejcmanová, L.; Syková, Eva

    2001-01-01

    Roč. 42, - (2001), s. 459-466 ISSN 0284-1851 R&D Projects: GA ČR GV309/97/K048; GA ČR GA309/99/0657; GA MŠk VS96130 Institutional research plan: CEZ:AV0Z5039906 Keywords : brain phenylketonuria MR imaging Subject RIV: FH - Neurology Impact factor: 0.914, year: 2001

  20. MR augmented cardiopulmonary exercise testing—a novel approach to assessing cardiovascular function

    International Nuclear Information System (INIS)

    Barber, Nathaniel J; Ako, Emmanuel O; Kowalik, Grzegorz T; Steeden, Jennifer A; Muthurangu, Vivek; Pandya, Bejal

    2015-01-01

    The purposes of this study were: (1) to evaluate feasibility and acceptability of MRI augmented cardiopulmonary exercise testing (MR-CPET) in healthy adults and (2) to test whether peak values obtained at conventional and MR-CPET correlate and to demonstrate variation in peak oxygen consumption (VO_2) relates to both peak cardiac output (CO) and peak oxygen extraction (ΔcO_2). Seventeen healthy adults underwent CPET and MR-CPET using an MR compatible ergometer and CPET system customised for MR use. Continuous aortic flow measurement used a validated UNFOLD-SENSE spiral phase contrast magnetic resonance (PCMR) sequence.Fifteen of 17 volunteers completed exercise; exclusions were due to claustrophobia and inability to effectively master exercise technique. Measures of acceptability were lower but still satisfactory for MR-CPET.There were strong correlations between conventional and MR-CPET for peak VO_2 (r = 0.94, p < 0.001); VCO_2 (r = 0.87, p < 0.001) and VE (r = 0.88, p < 0.001).Multiple linear regression analysis demonstrated peak CO and ΔcO_2 were independent predictors of peak VO_2 measured during MR-CPET (β = 0.73 and 0.38 p < 0.0001) and conventional CPET (β = 0.78, 0.28 p < 0.0001).MR-CPET is feasible, acceptable and demonstrates physiology not apparent with conventional CPET. MR-CPET allows differentiation of the contributions of CO and ΔcO_2 to variation in peak VO_2. We believe that this will be useful in understanding the origin of reduced exercise capacity in cardiac disease. (note)