WorldWideScience

Sample records for forward-looking intracardiac ultrasound

  1. Intravascular forward-looking ultrasound transducers for microbubble-mediated sonothrombolysis.

    Science.gov (United States)

    Kim, Jinwook; Lindsey, Brooks D; Chang, Wei-Yi; Dai, Xuming; Stavas, Joseph M; Dayton, Paul A; Jiang, Xiaoning

    2017-06-14

    Effective removal or dissolution of large blood clots remains a challenge in clinical treatment of acute thrombo-occlusive diseases. Here we report the development of an intravascular microbubble-mediated sonothrombolysis device for improving thrombolytic rate and thus minimizing the required dose of thrombolytic drugs. We hypothesize that a sub-megahertz, forward-looking ultrasound transducer with an integrated microbubble injection tube is more advantageous for efficient thrombolysis by enhancing cavitation-induced microstreaming than the conventional high-frequency, side-looking, catheter-mounted transducers. We developed custom miniaturized transducers and demonstrated that these transducers are able to generate sufficient pressure to induce cavitation of lipid-shelled microbubble contrast agents. Our technology demonstrates a thrombolysis rate of 0.7 ± 0.15 percent mass loss/min in vitro without any use of thrombolytic drugs.

  2. The Acoustic Lens Design and in Vivo Use of a Multifunctional Catheter Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    Science.gov (United States)

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Sahn, David

    2009-01-01

    A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning. Multiple electrophysiology mapping sensors were mounted as ring electrodes near the array for electrocardiographic synchronization of ultrasound images. The catheter array elevation beam performance in particular was investigated. An acoustic lens for the distal tip array designed with a round cross section can produce an acceptable elevation beam shape; however, the velocity of sound in the lens material should be approximately 155 m/s slower than in tissue for the best beam shape and wide bandwidth performance. To help establish the catheter’s unique ability for integration with electrophysiology interventional procedures, it was used in vivo in a porcine animal model, and demonstrated both useful intracardiac echocardiographic visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheter also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. PMID:18407850

  3. Intracardiac ultrasound scanner using a micromachine (MEMS) actuator.

    Science.gov (United States)

    Zara, J M; Bobbio, S M; Goodwin-Johansson, S; Smith, S W

    2000-01-01

    Catheter-based intracardiac ultrasound offers the potential for improved guidance of interventional cardiac procedures. The objective of this research is the development of catheter-based mechanical sector scanners incorporating high frequency ultrasound transducers operating at frequencies up to 20 MHz. The authors' current transducer assembly consists of a single 1.75 mm by 1.75 mm, 20 MHz, PZT element mounted on a 2 mm by 2 mm square, 75 mum thick polyimide table that pivots on 3-mum thick gold plated polyimide hinges. The hinges also serve as the electrical connections to the transducer. This table-mounted transducer is tilted using a miniature linear actuator to produce a sector scan. This linear actuator is an integrated force array (IFA), which is an example of a micromachine, i.e., a microelectromechanical system (MEMS). The IFA is a thin (2.2 mum) polyimide membrane, which consists of a network of hundreds of thousands of micron scale deformable capacitors made from pairs of metallized polyimide plates. IFAs contract with an applied voltage of 30-120 V and have been shown to produce strains as large as 20% and forces of up to 8 dynes. The prototype transducer and actuator assembly was fabricated and interfaced with a GagePCI analog to digital conversion board digitizing 12 bit samples at a rate of 100 MSamples/second housed in a personal computer to create a single channel ultrasound scanner. The deflection of the table transducer in a low viscosity insulating fluid (HFE 7100, 3M) is up to +/-10 degrees at scan rates of 10-60 Hz. Software has been developed to produce real-time sector scans on the PC monitor.

  4. Segmenting high-frequency intracardiac ultrasound images of myocardium into infarcted, ischemic, and normal regions.

    Science.gov (United States)

    Hao, X; Bruce, C J; Pislaru, C; Greenleaf, J F

    2001-12-01

    Segmenting abnormal from normal myocardium using high-frequency intracardiac echocardiography (ICE) images presents new challenges for image processing. Gray-level intensity and texture features of ICE images of myocardium with the same structural/perfusion properties differ. This significant limitation conflicts with the fundamental assumption on which existing segmentation techniques are based. This paper describes a new seeded region growing method to overcome the limitations of the existing segmentation techniques. Three criteria are used for region growing control: 1) Each pixel is merged into the globally closest region in the multifeature space. 2) "Geographic similarity" is introduced to overcome the problem that myocardial tissue, despite having the same property (i.e., perfusion status), may be segmented into several different regions using existing segmentation methods. 3) "Equal opportunity competence" criterion is employed making results independent of processing order. This novel segmentation method is applied to in vivo intracardiac ultrasound images using pathology as the reference method for the ground truth. The corresponding results demonstrate that this method is reliable and effective.

  5. Why do firms engage in forward-looking search?

    DEFF Research Database (Denmark)

    Jissink, Tymen; Rohrbeck, René; Huizingh, Eelko K.R.E.

    firms with a low level of slack resources engage to a much lower extent into forward-looking search, if they operate in high-competitive-intensity environments. Our findings not only carry important implications for predicting a firm’s engagement in forward-looking search, but also potentially...... performed below aspirations are less likely to engage in forward-looking search, suggesting that forward-looking search is not a form of problemistic search. In contrast, firms that have abundant uncommitted (slack) resources as well as firms expecting to outperform in the near future are engaging more...... into forward-looking search. We also find interaction effect between performance feedback and environmental characteristics. Interestingly firms with a high level of slack resources are only surpassing their less rich peers in forward-looking search, if they are in technologically turbulent environments. Also...

  6. 47 CFR 51.505 - Forward-looking economic cost.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Forward-looking economic cost. 51.505 Section... (CONTINUED) INTERCONNECTION Pricing of Elements § 51.505 Forward-looking economic cost. (a) In general. The forward-looking economic cost of an element equals the sum of: (1) The total element long-run incremental...

  7. Forward-Looking Search Within Innovation Projects

    DEFF Research Database (Denmark)

    Jissink, Tymen; Rohrbeck, René; Schweitzer, Fiona

    To develop highly-innovative projects, which are fraught with uncertainty and longer development times, one cannot solely rely on initial planning and budgeting to ensure the project’s outcome remains novel. This study posits that to develop innovative projects, project teams need to engage...... in forward-looking search during development to ensure the project’s outcome remains novel and relevant. We refer to forward-looking search as the search and evaluation of information on markets, customers, and technologies in terms of their future impact. Data on 159 unique innovation projects from...... the Danish manufacturing industry shows that forward-looking search significantly impacts innovativeness. The effect follows an inverted-U shape where the greatest positive effect on innovativeness occurs in moderately planned projects and significantly lower effects in low- and highly planned projects...

  8. Forward-Looking Betas

    DEFF Research Database (Denmark)

    Christoffersen, Peter; Jacobs, Kris; Vainberg, Gregory

    Few issues are more important for finance practice than the computation of market betas. Existing approaches compute market betas using historical data. While these approaches differ in terms of statistical sophistication and the modeling of the time-variation in the betas, they are all backward......-looking. This paper introduces a radically different approach to estimating market betas. Using the tools in Bakshi and Madan (2000) and Bakshi, Kapadia and Madan (2003) we employ the information embedded in the prices of individual stock options and index options to compute our forward-looking market beta...

  9. 47 CFR 51.513 - Proxies for forward-looking economic cost.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Proxies for forward-looking economic cost. 51... SERVICES (CONTINUED) INTERCONNECTION Pricing of Elements § 51.513 Proxies for forward-looking economic cost... a cost study that complies with the forward-looking economic cost based pricing methodology...

  10. Unpaid overtime in the Netherlands : forward- or backward-looking incentives?

    NARCIS (Netherlands)

    Van der Meer, Peter H.; Wielers, Rudi

    2015-01-01

    The purpose of this paper is to test forward-looking incentives against backward-looking incentives. Design/methodology/approach ? Wage growth model to estimate forward-looking effects of unpaid overtime and a probit model of participation in unpaid overtime controlling for excessive pay to estimate

  11. Volumetric Real-Time Imaging Using a CMUT Ring Array

    OpenAIRE

    Choe, Jung Woo; Oralkan, Ömer; Nikoozadeh, Amin; Gencel, Mustafa; Stephens, Douglas N.; O’Donnell, Matthew; Sahn, David J.; Khuri-Yakub, Butrus T.

    2012-01-01

    A ring array provides a very suitable geometry for forward-looking volumetric intracardiac and intravascular ultrasound imaging. We fabricated an annular 64-element capacitive micromachined ultrasonic transducer (CMUT) array featuring a 10-MHz operating frequency and a 1.27-mm outer radius. A custom software suite was developed to run on a PC-based imaging system for real-time imaging using this device.

  12. NPS ARIES Forward Look Sonar Integration

    National Research Council Canada - National Science Library

    Healey, A. J; Horner, D. P

    2004-01-01

    This work integrated an experimental Blazed Array Forward Looking Sonar (FLS) developed by the University of Washington, Applied Physics Laboratories into the ARIES autonomous underwater vehicle (AUV...

  13. Backward- and forward-looking potential of anaphors

    Directory of Open Access Journals (Sweden)

    Petra B. Schumacher

    2015-11-01

    Full Text Available Personal pronouns and demonstratives contribute differently to the encoding of information in the mental model and they serve distinct backward- and forward-looking functions. While (unstressed personal pronouns are the default means to indicate coreference with the most prominent discourse entity (backward-looking function and typically mark the maintenance of the current topic, demonstratives are used to refer to a less prominent entity and serve the additional forward-looking function of signaling a possible topic shift. In Experiment 1, we present an ERP study that examines the time course of processing personal and d-pronouns in German (er vs. der and assesses the impact of two prominence features of the antecedent, thematic role and sentential position, as well as neurophysiological correlates of backward- and forward-looking functions of referential expressions. We tested the comprehension of personal and d-pronouns following context sentences containing two potential antecedents. In addition to the factor pronoun type (er vs. der, we varied the verb type (active accusative verbs vs. dative experiencer verbs and the thematic role order (canonical vs. non-canonical in the context sentences to vary the antecedent’s prominence. Time-locked to pronoun-onset, the ERPs revealed a general biphasic N400-Late Positivity for d-pronouns over personal pronouns with further subtle interactions of the prominence-lending cues in the early time window. The findings indicate that the calculation of the referential candidates’ prominence (backward-looking function is guided by thematic role and positional information. Thematic role information, in combination with initial position, thus represents a central predictor during referential processing. Coreference with a less prominent entity (assumed for d-pronouns results in processing costs (N400. The additional topic shift signaled by d-pronouns (forward-looking function results in attentional

  14. Ultrasound imaging-guided intracardiac injection to develop a mouse model of breast cancer brain metastases followed by longitudinal MRI.

    Science.gov (United States)

    Zhou, Heling; Zhao, Dawen

    2014-03-06

    Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.

  15. Forward-looking disclosure and corporate reputation as mechanisms to reduce stock return volatility

    Directory of Open Access Journals (Sweden)

    Francisco Bravo

    2016-01-01

    Full Text Available The purpose of this paper is to investigate whether forward-looking disclosures and corporate reputation lead to a reduction in stock return volatility. This study measures financial forward-looking information, by conducting a content analysis of annual reports for a sample of US companies. Since every annual report was manually examined and coded, the study is therefore restricted to the companies listed in Standard and Poor's 100. Results show that financial forward-looking information has significant effects on capital markets. This study contributes to the current literature on voluntary disclosure, by examining the link between the disclosure of financial forward-looking information and stock return volatility. Since stock volatility is linked to information asymmetries and to a higher risk of a company, this analysis implies certain practical implications for both managers and regulators regarding the importance of specific disclosure strategy in capital markets. Moreover, results indicate that forward-looking information disclosed by companies of a higher reputation has a greater effect on stock return volatility. This is the first study that demonstrates that corporate reputation moderates the effects of forward-looking information in capital markets. In addition to the level of disclosed information, the interpretation and the effectiveness of forward-looking information depends on the reputation of a company.

  16. Malaysian Economic Development: Looking Backwards and Forward

    OpenAIRE

    Hal Hill

    2010-01-01

    This paper provides an analytical and forward-looking overview of Malaysian economic development. Looking back over its 53 years of Independence, we identify the key stylized facts to include the country's generally rapid economic growth and structural change; its consistent openness, especially for merchandize trade and foreign direct investment; its creditable record of macroeconomic management; its consistently high inequality, in spite of the developing world's most consistently implement...

  17. The forward-looking disclosures of corporate managers: theory and evidence

    OpenAIRE

    Gropp, Reint; Karapandza, Rasa; Opferkuch, Julian

    2016-01-01

    We consider an infinitely repeated game in which a privately informed, long-lived manager raises funds from short-lived investors in order to finance a project. The manager can signal project quality to investors by making a (possibly costly) forward-looking disclosure about her project's potential for success. We find that if the manager's disclosures are costly, she will never release forward-looking statements that do not convey information to external investors. Furthermore, managers of f...

  18. Accounting Fundamentals and Variations of Stock Price: Forward Looking Information Inducement

    OpenAIRE

    Sumiyana, Sumiyana

    2011-01-01

    This study investigates a permanent issue about low association between accounting fundamentals and variations of stock prices. It induces not only historical accountingfundamentals, but also forward looking information. Investors consider forward looking information that enables them to predict potential future cash flow, increase predictive power, lessen mispricing error, increase information content and drives future price equilibrium. The accounting fundamentals are earnings yield, book v...

  19. The Accountability Era in US Teacher Education: Looking Back, Looking Forward

    Science.gov (United States)

    Cochran-Smith, Marilyn; Baker, Megina; Burton, Stephani; Chang, Wen-Chia; Cummings Carney, Molly; Fernández, M. Beatriz; Stringer Keefe, Elizabeth; Miller, Andrew F.; Sánchez, Juan Gabriel

    2017-01-01

    In keeping with the theme of the 40th anniversary issue of "EJTE," this article looks back and forward at US teacher education accountability. It argues that "holding teacher education accountable" has been the major approach to reforming teacher education in the US for the last two decades, assuming that enhanced teacher…

  20. Comparison of vehicle-mounted forward-looking polarimetric infrared and downward-looking infrared sensors for landmine detection

    NARCIS (Netherlands)

    Cremer, F.; Schavemaker, J.G.M.; Jong, W. de; Schutte, K.

    2003-01-01

    This paper gives a comparison of two vehicle-mounted infrared systems for landmine detection. The first system is a down-ward looking standard infrared camera using processing methods developed within the EU project LOTUS. The second system is using a forward-looking polarimetric infrared camera.

  1. Network Analysis in Community Psychology: Looking Back, Looking Forward.

    Science.gov (United States)

    Neal, Zachary P; Neal, Jennifer Watling

    2017-09-01

    Network analysis holds promise for community psychology given the field's aim to understand the interplay between individuals and their social contexts. Indeed, because network analysis focuses explicitly on patterns of relationships between actors, its theories and methods are inherently extra-individual in nature and particularly well suited to characterizing social contexts. But, to what extent has community psychology taken advantage of this network analysis as a tool for capturing context? To answer these questions, this study provides a review of the use network analysis in articles published in American Journal of Community Psychology. Looking back, we describe and summarize the ways that network analysis has been employed in community psychology research to understand the range of ways community psychologists have found the technique helpful. Looking forward and paying particular attention to analytic issues identified in past applications, we provide some recommendations drawn from the network analysis literature to facilitate future applications of network analysis in community psychology. © 2017 The Authors. American Journal of Community Psychology published by Wiley Periodicals, Inc. on behalf of Society for Community Research and Action.

  2. Backward- and forward-looking responsibility for obesity: policies from WHO, the EU and England.

    Science.gov (United States)

    Vallgårda, Signild; Nielsen, Morten Ebbe Juul; Hartlev, Mette; Sandøe, Peter

    2015-10-01

    In assigning responsibility for obesity prevention a distinction may be drawn between who is responsible for the rise in obesity prevalence ('backward-looking responsibility'), and who is responsible for reducing it ('forward-looking responsibility'). We study how the two aspects of responsibility figure in the obesity policies of WHO (European Region), the EU and the Department of Health (England). Responsibility for the emergence and reduction of obesity is assigned to both individuals and other actors to different degrees in the policies, combining an individual and a systemic view. The policies assign backward-looking responsibility to individuals, the social environment, the authorities and businesses. When it comes to forward-looking responsibility, individuals are expected to play a central role in reducing and preventing obesity, but other actors are also urged to act. WHO assigns to individuals the lowest degree of backward- and forward-looking responsibility, and the Department of Health (England) assigns them the highest degree of responsibility. Differences in the assignment of backward- and above all forward-looking responsibility could be explained to some extent by the different roles of the three authorities making the plans. WHO is a UN agency with health as its goal, the EU is a liberal economic union with optimization of the internal European market as an important task, and England, as an independent sovereign country, has its own economic responsibilities. © The Author 2015. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  3. Study of intracardiac blood flow by MRI using gradient echo method

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato; Morita, Ruriko; Kusuoka, Hideo; Fujii, Kenshi; Kitabatake, Akira; Takizawa, Osamu.

    1988-06-01

    In order to investigate the possibility of MR imaging for the evaluation of intracardiac blood flow especially valvular regurgitant flow, we obtained MR images using a 1.5 tesla superconductive magnet system (Siemens Medical) in 3 healthy volunteers, 3 patients with hypertrophic cardiomyopathy and 8 patients with valvular heart disease. Rapid FLASH (Fast Low-Angle Shot) imaging technique was applied to collect 11 time frames per section throughout one cardiac cycle in axial, coronal, saggital and oblique sections. Then these sequential frames were displayed in a cine mode on CRT. (1) Intracardiac and intravascular blood flow were visualized with high signal intensity in each frame and cardiac structures such as atria, ventricles, and aorta were also identified in all subjects. (2) Ventricular ejection flow was easily visualized in coronal section as the signal loss in the ascending aorta. Ventricularfilling was visualized in axial and oblique sections as the high signal influx of atrial blood into the ventricle. (3) In 3 patients with aortic regurgitation, regurgitant flow was detected during diastole as the teardrop shaped signal loss originating from aortic valve cusps. (4) Both mitral and tricuspid regurgitant flow were detected during systole as the signal loss in atrium in axial and oblique sections in 2 patients with MR and 2 patients with TR. (5) Pulmonary regurgitant flow was observed in oblique section along the long axis of right ventricular outflow tract. These results indicate that intracardiac forward and regurgitant flow could be identified with rapid FLASH imaging in normal subjects and in patients with valvular heart diseases, and cine mode MR imaging is a useful tool for the evaluation of intracardiac blood flow.

  4. Note: Folded optical system for narrow forward looking probe

    International Nuclear Information System (INIS)

    Hou, Hsuan-Chao; Hah, Dooyoung; Kim, Jeonghwan; Feldman, M.

    2014-01-01

    An optical system is described in which a laser beam makes three passes through a single graded index lens, forming a focus along the optic axis. It has important applications in endoscopic probes, where the forward looking characteristic permits the avoidance of obstacles and the narrow structure makes it minimally invasive

  5. A study of intracardiac blood flow by MRI using gradient echo method

    International Nuclear Information System (INIS)

    Ohnishi, Shusaku; Fukui, Sugao; Atsumi, Chisato; Morita, Ruriko; Kusuoka, Hideo; Fujii, Kenshi; Kitabatake, Akira; Takizawa, Osamu.

    1988-01-01

    In order to investigate the possibility of MR imaging for the evaluation of intracardiac blood flow especially valvular regurgitant flow, we obtained MR images using a 1.5 tesla superconductive magnet system (Siemens Medical) in 3 healthy volunteers, 3 patients with hypertrophic cardiomyopathy and 8 patients with valvular heart disease. Rapid FLASH (Fast Low-Angle Shot) imaging technique was applied to collect 11 time frames per section throughout one cardiac cycle in axial, coronal, saggital and oblique sections. Then these sequential frames were displayed in a cine mode on CRT. (1) Intracardiac and intravascular blood flow were visualized with high signal intensity in each frame and cardiac structures such as atria, ventricles, and aorta were also identified in all subjects. (2) Ventricular ejection flow was easily visualized in coronal section as the signal loss in the ascending aorta. Ventricularfilling was visualized in axial and oblique sections as the high signal influx of atrial blood into the ventricle. (3) In 3 patients with aortic regurgitation, regurgitant flow was detected during diastole as the teardrop shaped signal loss originating from aortic valve cusps. (4) Both mitral and tricuspid regurgitant flow were detected during systole as the signal loss in atrium in axial and oblique sections in 2 patients with MR and 2 patients with TR. (5) Pulmonary regurgitant flow was observed in oblique section along the long axis of right ventricular outflow tract. These results indicate that intracardiac forward and regurgitant flow could be identified with rapid FLASH imaging in normal subjects and in patients with valvular heart diseases, and cine mode MR imaging is a useful tool for the evaluation of intracardiac blood flow. (author)

  6. A look back and a look forward

    International Nuclear Information System (INIS)

    McDonald, J. C.

    2012-01-01

    Roman mythology described Janus as the god of beginnings and transitions. Janus was depicted as having two heads facing in opposite directions that could be thought of as the future and the past. Therefore, it is altogether appropriate that the first month of our calendar should be named after Janus because it is a time of passage from the old to the new year. There were a number of significant events and developments during the past year, and one can look forward to a number of new and, perhaps, unexpected developments during the year to come. The year 2011 saw the tragedy of a major earthquake and Tsunami in Japan resulting in a disastrous series of explosions at the Fukushima I Nuclear Power Plant. Releases of radionuclides to the atmosphere and depositions in the immediate vicinity of the plant have required remediation efforts on the part of the Japanese government, with help from a number of other nations. This accident was classified as Level 7, the highest level, on the International Nuclear Event Scale. (author)

  7. Essays in forward looking behavior in strategic interactions

    OpenAIRE

    Mantovani, Marco

    2013-01-01

    The general topic of our thesis is forward looking behavior in strategic situations. Mixing theoretical and experimental analysis, we document how strategic thinking is affected by the specific features of a dynamic interaction. The overarching result is that the information regarding decisions that are close to the current one, receive a qualitatively different consideration, with respect to distant ones. That is, the actual decisions are based on reasoning over a limited number of steps, cl...

  8. Forward-Looking Planning of Technology Development

    Directory of Open Access Journals (Sweden)

    Katarzyna Halicka

    2015-12-01

    Full Text Available The main aim of this article is to adapt the Future-Oriented Technology Analysis (FTA to prospective planning of technology development. Firstly, the article presents the assumptions, methods and idea, as well as the concept of the FTA method. Moreover, selected publications on the use of this method were analysed. Then, an original, base model of forward-looking planning of technology development was constructed and presented. The end result of this process will be the development of the localized in time, presented in graphic form, action plan referred to as the route of technology development. Basing on the literature review and the research projects a preliminary route of development of arbitrarily chosen technology was also built and presented.

  9. Backward- and forward-looking responsibility for obesity: policies from WHO, the EU and England

    DEFF Research Database (Denmark)

    Vallgårda, Signild; Nielsen, Morten Ebbe Juul; Hartlev, Mette

    2015-01-01

    ackground: In assigning responsibility for obesity prevention a distinction may be drawn between who is responsible for the rise in obesity prevalence (‘backward-looking responsibility’), and who is responsible for reducing it (‘forward-looking responsibility’). Methods: We study how the two aspe...

  10. Automated vehicle detection in forward-looking infrared imagery.

    Science.gov (United States)

    Der, Sandor; Chan, Alex; Nasrabadi, Nasser; Kwon, Heesung

    2004-01-10

    We describe an algorithm for the detection and clutter rejection of military vehicles in forward-looking infrared (FLIR) imagery. The detection algorithm is designed to be a prescreener that selects regions for further analysis and uses a spatial anomaly approach that looks for target-sized regions of the image that differ in texture, brightness, edge strength, or other spatial characteristics. The features are linearly combined to form a confidence image that is thresholded to find likely target locations. The clutter rejection portion uses target-specific information extracted from training samples to reduce the false alarms of the detector. The outputs of the clutter rejecter and detector are combined by a higher-level evidence integrator to improve performance over simple concatenation of the detector and clutter rejecter. The algorithm has been applied to a large number of FLIR imagery sets, and some of these results are presented here.

  11. An improved lattice hydrodynamic model considering the influence of optimal flux for forward looking sites

    Science.gov (United States)

    Wang, Yunong; Ge, Hongxia; Cheng, Rongjun

    2017-11-01

    In this paper, a lattice hydrodynamic model is derived considering the delayed-feedback control influence of optimal flux for forward looking sites on a single-lane road which includes more comprehensive information. The control method is used to analyze the stability of the model. The critical condition for the linear steady traffic flow is deduced and the numerical simulation is carried out to investigate the advantage of the proposed model with and without the effect of optimal flux for forward looking sites. Moreover it indicates that the characteristic of the model can lead to a lower energy consumption in traffic system. The results are consistent with the theoretical analysis correspondingly.

  12. MRI screening-detected breast lesions in high-risk young women: the value of targeted second-look ultrasound and imaging-guided biopsy.

    Science.gov (United States)

    Peter, P; Dhillon, R; Bose, S; Bourke, A

    2016-10-01

    To analyse the value of targeted second-look ultrasound and imaging-guided biopsy in high-risk young women eligible for screening magnetic resonance imaging (MRI) in a tertiary referral centre in Perth, Western Australia. A retrospective analysis of eligible high-risk young women who underwent screening breast MRI and targeted second-look ultrasound between June 2012 and June 2014 was performed with review of data. Over a 2-year period, 139 women underwent high-risk screening MRI. Of these, 30 women (with a total of 45 lesions) were recalled for targeted second-look ultrasound. Thirty-four MRI-detected lesions were identified on targeted ultrasound with 19 of them proceeding to ultrasound-guided biopsy, while the remaining 15 lesions were considered benign on ultrasound, were not biopsied, and were stable on follow-up imaging 12 months later. One lesion proceeded to an MRI-guided biopsy to confirm a benign result. Of the 11 lesions not seen on ultrasound, nine underwent MRI biopsy, one proceeded directly to hook wire localisation and excision, and one did not return for biopsy and was lost to follow-up. The overall biopsy rate was 14.4%. The cancer detection rate was 1.4%. The results of this study indicate that targeted second-look ultrasound and ultrasound-guided biopsy is a cost-effective and time-efficient approach for MRI-detected lesions in young women at high risk of developing breast cancer. MRI-guided biopsy should be considered for ultrasonographically occult suspicious lesions as there is a low, but definite, risk of cancer. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Looking forward

    DEFF Research Database (Denmark)

    Just, Sine Nørholm; Mouton, Nicolaas T.O.; Gabrielsen, Jonas

    2013-01-01

    Forecasts are central to processes of market formation; they partake in the performativity of markets by visualising market developments and directing market actors' gaze towards these developments. Thus, forecasting is a certain way of looking that may be said to bring into being what it sees - ...

  14. Going Concern Opinions and Management's Forward Looking Disclosures: Evidence from the MD&A

    NARCIS (Netherlands)

    Enev, M.; Geiger, Marshall; Gold, A.H.; Wallage, P.

    In this study we examine the relationship between the auditor’s going concern opinion and management’s forward-looking disclosures in the Management’s Discussion and Analysis (MD&A) section of 10-K filings. The research objective is two-fold and addresses whether the presence of a going concern

  15. Coupling Climate Models and Forward-Looking Economic Models

    Science.gov (United States)

    Judd, K.; Brock, W. A.

    2010-12-01

    Authors: Dr. Kenneth L. Judd, Hoover Institution, and Prof. William A. Brock, University of Wisconsin Current climate models range from General Circulation Models (GCM’s) with millions of degrees of freedom to models with few degrees of freedom. Simple Energy Balance Climate Models (EBCM’s) help us understand the dynamics of GCM’s. The same is true in economics with Computable General Equilibrium Models (CGE’s) where some models are infinite-dimensional multidimensional differential equations but some are simple models. Nordhaus (2007, 2010) couples a simple EBCM with a simple economic model. One- and two- dimensional ECBM’s do better at approximating damages across the globe and positive and negative feedbacks from anthroprogenic forcing (North etal. (1981), Wu and North (2007)). A proper coupling of climate and economic systems is crucial for arriving at effective policies. Brock and Xepapadeas (2010) have used Fourier/Legendre based expansions to study the shape of socially optimal carbon taxes over time at the planetary level in the face of damages caused by polar ice cap melt (as discussed by Oppenheimer, 2005) but in only a “one dimensional” EBCM. Economists have used orthogonal polynomial expansions to solve dynamic, forward-looking economic models (Judd, 1992, 1998). This presentation will couple EBCM climate models with basic forward-looking economic models, and examine the effectiveness and scaling properties of alternative solution methods. We will use a two dimensional EBCM model on the sphere (Wu and North, 2007) and a multicountry, multisector regional model of the economic system. Our aim will be to gain insights into intertemporal shape of the optimal carbon tax schedule, and its impact on global food production, as modeled by Golub and Hertel (2009). We will initially have limited computing resources and will need to focus on highly aggregated models. However, this will be more complex than existing models with forward-looking

  16. A lot to look forward to

    CERN Multimedia

    2013-01-01

    CERN moves from momentous year to momentous year, and although 2013 will be very different for us than 2012, there is still a lot to look forward to. As I write, the proton-lead run is just getting under way, giving the LHC experiments a new kind of data to investigate. But the run will be short, and our main activity this year will be the start of the LHC’s first long shutdown.   This is the first year I can remember in which all of CERN’s accelerators will be off. The reason is that there is much to be done: the older machines need maintenance, and the LHC has to be prepared for higher energy running. That involves opening up the interconnections between each of the machine’s 1,695 main magnet cryostats, consolidating all of the 10,170 splices carrying current to the main dipole and quadrupole windings, and a range of other work to improve the machine. The CERN accelerator complex will start to come back to life in 2014, and it’s fair to say that when...

  17. New approach to intracardiac hemodynamic measurements in small animals

    DEFF Research Database (Denmark)

    Eskesen, Kristian; Olsen, Niels T; Dimaano, Veronica L

    2012-01-01

    Invasive measurements of intracardiac hemodynamics in animal models have allowed important advances in the understanding of cardiac disease. Currently they are performed either through a carotid arteriotomy or via a thoracotomy and apical insertion. Both of these techniques have disadvantages...... and are not conducive to repeated measurements. Therefore, the purpose of this study was to develop a new technique for measuring intracardiac hemodynamics....

  18. Disseminated intravascular and intracardiac thrombosis after cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Deepak K Tempe

    2017-01-01

    Full Text Available Massive intracardiac and intravascular thrombosis is a rare complication following cardiopulmonary bypass (CPB. Most of the cases of the disseminated thrombosis have been reported in patients undergoing complex cardiac surgeries and those receiving antifibrinolytic agents during CPB. We report the occurrence of disseminated intravascular and intracardiac thrombosis after CPB in a patient undergoing mitral valve replacement in which no antifibrinolytic agent was used. The possible pathophysiology and management of the patient is discussed.

  19. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  20. Looking forward to a PET scanner designed for non-human primates

    International Nuclear Information System (INIS)

    Tanaka, Keiji

    1992-01-01

    The cerebral cortex of non-human primates has been divided, mainly by anatomical techniques, into an enormous number of areas. We are looking forward to a PET scanner designed for non-human primates, with a hope to determine active brain regions when the animal does various cognitive tasks. This measurement with PET can be combined with single cell recordings and anatomical tracer studies in non-human primates. Another big hope is to detect a change of active regions as the learning advances. (author)

  1. A Forward-looking Model of the Term Structure of Interest Rates

    DEFF Research Database (Denmark)

    Chun, Albert Lee

    of the forecasts are modeled jointly with the physical process driving their realizations. We extend this framework to allow for multiple-horizon forecasts to drive the short rate, yielding its novel interpretation as a forward-looking multiple-horizon monetary policy rule, which facilitates a decomposition...... of monetary policy and the yield curve into short and long horizon expectations. While short horizon forecasts can pin down the short rate, long horizon forecasts embed information that better describes longer maturity yields. In addition, short horizon forecasts of real output growth are obscured...

  2. A 10-Fr ultrasound catheter with integrated micromotor for 4-D intracardiac echocardiography.

    Science.gov (United States)

    Lee, Warren; Griffin, Weston; Wildes, Douglas; Buckley, Donald; Topka, Terry; Chodakauskas, Thaddeus; Langer, Mark; Calisti, Serge; Bergstøl, Svein; Malacrida, Jean-Pierre; Lanteri, Frédéric; Maffre, Jennifer; McDaniel, Ben; Shivkumar, Kalyanam; Cummings, Jennifer; Callans, David; Silvestry, Frank; Packer, Douglas

    2011-07-01

    We developed prototype real-time 3-D intracardiac echocardiography catheters with integrated micromotors, allowing internal oscillation of a low-profile 64-element, 6.2-MHz phased-array transducer in the elevation direction. Components were designed to facilitate rotation of the array, including a low-torque flexible transducer interconnect and miniature fixtures for the transducer and micromotor. The catheter tip prototypes were integrated with two-way deflectable 10-Fr catheters and used in in vivo animal testing at multiple facilities. The 4-D ICE catheters were capable of imaging a 90° azimuth by up to 180° elevation field of view. Volume rates ranged from 1 vol/sec (180° elevation) to approximately 10 vol/sec (60° elevation). We successfully imaged electrophysiology catheters, atrial septal puncture procedures, and detailed cardiac anatomy. The elevation oscillation enabled 3-D visualization of devices and anatomy, providing new clinical information and perspective not possible with current 2-D imaging catheters.

  3. Multiple Kernel Learning for Explosive Hazard Detection in Forward-Looking Ground-Penetrating Radar

    Science.gov (United States)

    2012-04-01

    Kevin Stone, Derek T. Anderson, James M. Keller, Dominic K.C. Ho, Tuan T. Ton, David C. Wong , Mehrdad Soumekh University of Missouri - Columbia...James M. Kellera, K.C. Hoa, Tuan T. Tone, David C. Wong\\ and Mehrdad Soumekhd aDept. ofElectrical and Computer Engineering, University of Missouri...2] Cremer , F., Schavemaker, J.G., de Jong, W., and Schutte, K., "Comparison of vehicle-mounted forward-looking polarimetric infrared and downward

  4. A Bone Metastasis Nude Mouse Model Created by Ultrasound Guided Intracardiac Injection of Breast Cancer Cells: the Micro-CT, MRI and Bioluminescence Imaging Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Jin; Song, Eun Hye; Kim, Seol Hwa; Song, Ho Taek; Suh, Jin Suck [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Sang Hyun [Korean Minjok Leadership Academy, Heongsung (Korea, Republic of)

    2011-01-15

    The purpose of this study was to develop a nude mouse model of bone metastasis by performing intracardiac injection of breast cancer cells under ultrasonography guidance and we wanted to evaluate the development and the distribution of metastasis in vivo using micro-CT, MRI and bioluminescence imaging. Animal experiments were performed in 6-week-old female nude mice. The animals underwent left ventricular injection of 2x105 MDA-MB-231Bo-Luc cells. After injection of the tumor cells, serial bioluminescence imaging was performed for 7 weeks. The findings of micro-CT, MRI and the histology were correlated with the 'hot' lesions seen on the bioluminescence imaging. Metastasis was found in 62.3% of the animals. Two weeks after intracardiac injection, metastasis to the brain, spine and femur was detected with bioluminescence imaging with an increasing intensity by week 7. Micro-CT scan confirmed multiple osteolytic lesions at the femur, spine and skull. MRI and the histology were able to show metastasis in the brain and extraskeletal metastasis around the femur. The intracardiac injection of cancer cells under ultrasonography guidance is a safe and highly reproducible method to produce bone metastasis in nude mice. This bone metastasis nude mouse model will be useful to study the mechanism of bone metastasis and to validate new therapeutics

  5. Real-time data for estimating a forward-looking interest rate rule of the ECB

    Directory of Open Access Journals (Sweden)

    Tilman Bletzinger

    2017-12-01

    Full Text Available The purpose of the data presented in this article is to use it in ex post estimations of interest rate decisions by the European Central Bank (ECB, as it is done by Bletzinger and Wieland (2017 [1]. The data is of quarterly frequency from 1999 Q1 until 2013 Q2 and consists of the ECB's policy rate, inflation rate, real output growth and potential output growth in the euro area. To account for forward-looking decision making in the interest rate rule, the data consists of expectations about future inflation and output dynamics. While potential output is constructed based on data from the European Commission's annual macro-economic database, inflation and real output growth are taken from two different sources both provided by the ECB: the Survey of Professional Forecasters and projections made by ECB staff. Careful attention was given to the publication date of the collected data to ensure a real-time dataset only consisting of information which was available to the decision makers at the time of the decision. Keywords: Interest rate rule estimation, Real-time data, Forward-looking data

  6. Clinical and histologic effects of intracardiac administration of propofol for induction of anesthesia in ball pythons (Python regius).

    Science.gov (United States)

    McFadden, Michael S; Bennett, R Avery; Reavill, Drury R; Ragetly, Guillaume R; Clark-Price, Stuart C

    2011-09-15

    To assess the clinical differences between induction of anesthesia in ball pythons with intracardiac administration of propofol and induction with isoflurane in oxygen and to assess the histologic findings over time in hearts following intracardiac administration of propofol. Prospective randomized study. 30 hatchling ball pythons (Python regius). Anesthesia was induced with intracardiac administration of propofol (10 mg/kg [4.5 mg/lb]) in 18 ball pythons and with 5% isoflurane in oxygen in 12 ball pythons. Induction time, time of anesthesia, and recovery time were recorded. Hearts from snakes receiving intracardiac administration of propofol were evaluated histologically 3, 7, 14, 30, and 60 days following propofol administration. Induction time with intracardiac administration of propofol was significantly shorter than induction time with 5% isoflurane in oxygen. No significant differences were found in total anesthesia time. Recovery following intracardiac administration of propofol was significantly longer than recovery following induction of anesthesia with isoflurane in oxygen. Heart tissue evaluated histologically at 3, 7, and 14 days following intracardiac administration of propofol had mild inflammatory changes, and no histopathologic lesions were seen 30 and 60 days following propofol administration. Intracardiac injection of propofol in snakes is safe and provides a rapid induction of anesthesia but leads to prolonged recovery, compared with that following induction with isoflurane. Histopathologic lesions in heart tissues following intracardiac injection of propofol were mild and resolved after 14 days.

  7. Distribution, structure and projections of the frog intracardiac neurons.

    Science.gov (United States)

    Batulevicius, Darius; Skripkiene, Gertruda; Batuleviciene, Vaida; Skripka, Valdas; Dabuzinskiene, Anita; Pauza, Dainius H

    2012-05-21

    Histochemistry for acetylcholinesterase was used to determine the distribution of intracardiac neurons in the frog Rana temporaria. Seventy-nine intracardiac neurons from 13 frogs were labelled iontophoretically by the intracellular markers Alexa Fluor 568 and Lucifer Yellow CH to determine their structure and projections. Total neuronal number per frog heart was (Mean ± SE) 1374 ± 56. Largest collections of neurons were found in the interatrial septum (46%), atrioventricular junction (25%) and venal sinus (12%). Among the intracellularly labelled neurons, we found the cells of unipolar (71%), multipolar (20%) and bipolar (9%) types. Multiple processes originated from the neuron soma, hillock and proximal axon. These processes projected onto adjacent neuron somata and cardiac muscle fibers within the interatrial septum. Average total length of the processes from proximal axon was 348 ± 50 μm. Average total length of processes from soma and hillock was less, 118 ± 27 μm and 109 ± 24 μm, respectively. The somata of 59% of neurons had bubble- or flake-shaped extensions. Most neurons from the major nerves in the interatrial septum sent their axons towards the ventricle. In contrast, most neurons from the ventral part of the interatrial septum sent their axons towards the atria. Our findings contradict to a view that the frog intracardiac ganglia contain only non-dendritic neurons of the unipolar type. We conclude that the frog intracardiac neurons are structurally complex and diverse. This diversity may account for the complicated integrative functions of the frog intrinsic cardiac ganglia. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. A forward looking, actor based, indicator for climate gas emissions

    Energy Technology Data Exchange (ETDEWEB)

    Ericson, Torgeir; Randers, Joergen

    2011-04-15

    The most commonly used Norwegian indicator for climate change displays historical emissions and compare with Norway's Kyoto target. This indicator says little about future emissions, about the ongoing Norwegian effort to reduce climate gas emissions, or about its effect on sustainability. In this paper we propose an indicator that improves on these weaknesses. We present a forward looking climate indicator that in addition to historic data includes business as usual scenarios, different proposals for future domestic emissions, and national or international commitments and agreements. This indicator presents - in one graph - a broad diversity of views on how the climate challenge should be handled from now and into the future. This indicator-graph may contribute to a more transparent discussion of available policy options. (Author)

  9. Ultrasound of the axilla: where to look for the sentinel lymph node

    International Nuclear Information System (INIS)

    Britton, P.; Moyle, P.; Benson, J.R.; Goud, A.; Sinnatamby, R.; Barter, S.; Gaskarth, M.; Provenzano, E.; Wallis, M.

    2010-01-01

    Aims: The aim of this paper is to guide the radiologist to the most likely location of the sentinel lymph node (SLN). Materials and methods: Patients with invasive breast cancer underwent axillary ultrasound examination. The position and morphological appearances of the lymph nodes were noted and core biopsy (CB) was performed of the largest or most suspicious node. Those patients whose biopsy revealed no evidence of malignancy proceeded to a surgical sentinel lymph node (SLN) biopsy (SLNB) looking for histopathological evidence of previous CB. Results: Of 121 patients who underwent axillary ultrasound and CB no malignancy was identified in 73, all of whom subsequently underwent SLNB. Histological evidence of CB in the SLN was identified in 47 (64%) patients. The position of all the lymph nodes identified on ultrasound and the 47 patients whose SLNs were identified were drawn on composite diagrams of the axilla. Of the 36 nodes identified as sentinel whose position relative to other nodes could be determined, 29 (81%) represented the lowest node identified in the axilla, four (11%) were the second lowest, and three (8%) were the third lowest node. None of the four patients whose CB was from the fourth lowest node had the CB site identified at subsequent SLNB. Conclusion: Ultrasound of the axilla should be carried out in a systematic fashion focusing on level I nodes paying particular attention to the lowest one or two lymph nodes.

  10. Ultrasound of the axilla: where to look for the sentinel lymph node

    Energy Technology Data Exchange (ETDEWEB)

    Britton, P., E-mail: peter.britton@addenbrookes.nhs.u [Cambridge Breast Unit, Addenbrooke' s Hospital, Cambridge (United Kingdom); Moyle, P.; Benson, J.R.; Goud, A.; Sinnatamby, R.; Barter, S.; Gaskarth, M.; Provenzano, E.; Wallis, M. [Cambridge Breast Unit, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2010-05-15

    Aims: The aim of this paper is to guide the radiologist to the most likely location of the sentinel lymph node (SLN). Materials and methods: Patients with invasive breast cancer underwent axillary ultrasound examination. The position and morphological appearances of the lymph nodes were noted and core biopsy (CB) was performed of the largest or most suspicious node. Those patients whose biopsy revealed no evidence of malignancy proceeded to a surgical sentinel lymph node (SLN) biopsy (SLNB) looking for histopathological evidence of previous CB. Results: Of 121 patients who underwent axillary ultrasound and CB no malignancy was identified in 73, all of whom subsequently underwent SLNB. Histological evidence of CB in the SLN was identified in 47 (64%) patients. The position of all the lymph nodes identified on ultrasound and the 47 patients whose SLNs were identified were drawn on composite diagrams of the axilla. Of the 36 nodes identified as sentinel whose position relative to other nodes could be determined, 29 (81%) represented the lowest node identified in the axilla, four (11%) were the second lowest, and three (8%) were the third lowest node. None of the four patients whose CB was from the fourth lowest node had the CB site identified at subsequent SLNB. Conclusion: Ultrasound of the axilla should be carried out in a systematic fashion focusing on level I nodes paying particular attention to the lowest one or two lymph nodes.

  11. Uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases on FDG PET/CT: A case report

    International Nuclear Information System (INIS)

    Wang, Hui Chun; Wang, Yu Bin; Chen, Xiao Hong; Cu, Lan Lan

    2016-01-01

    A 48-year-old woman presented with a 50-day history of irregular vaginal bleeding and lower abdominal pain. Ultrasound indicated an extremely large occupying lesion in the pelvic cavity that was highly suggestive of malignancy. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) was performed to further assess the nature of pelvic abnormality. PET/CT images demonstrated a diffusely lobulated mass ranging from cervix up to the inferior pole of kidneys with mild FDG uptake. Simultaneously, multiple nodules in bilateral lungs and a hypodense lesion in the right ventricle were shown without FDG-avidity. Based on the imaging results, the presumptive diagnosis was uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases, which was subsequently confirmed by MRI and the lesion biopsy

  12. Uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases on FDG PET/CT: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Hui Chun; Wang, Yu Bin; Chen, Xiao Hong; Cu, Lan Lan [PET/CT Center, Gansu Provincial Hospital, Lanzhou (China)

    2016-04-15

    A 48-year-old woman presented with a 50-day history of irregular vaginal bleeding and lower abdominal pain. Ultrasound indicated an extremely large occupying lesion in the pelvic cavity that was highly suggestive of malignancy. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) was performed to further assess the nature of pelvic abnormality. PET/CT images demonstrated a diffusely lobulated mass ranging from cervix up to the inferior pole of kidneys with mild FDG uptake. Simultaneously, multiple nodules in bilateral lungs and a hypodense lesion in the right ventricle were shown without FDG-avidity. Based on the imaging results, the presumptive diagnosis was uterine intravenous leiomyomatosis with intracardiac extension and pulmonary benign metastases, which was subsequently confirmed by MRI and the lesion biopsy.

  13. Detection of intracardiac shunts with contrast-enhanced dynamic MR imaging

    International Nuclear Information System (INIS)

    Manning, W.J.; Atkinson, D.J.; Parker, J.A.; Edelman, R.R.

    1990-01-01

    This paper reports on ultrafast MR imaging with bolus administration of Gd-DTPA used to detect intracardiac shunts. Ten patients who had recently undergone cardiac catheterization or first-pass radionuclide evaluation were selected for study. These included five patients without intracardiac shunts and five patients with shunts (three with atrial septal defect, two with ventricular septal defect). Resting four-chamber cardiac images were obtained during intravenous injection of Gd-DTPA (0.02 mmol/kg) with an ultrafast, T1-weighted sequence. Images were acquired over 380 msec, with repetitive images obtained with each QRS for 50 beats. In addition, standard MR cine examinations were performed

  14. An Adaptive Moving Target Imaging Method for Bistatic Forward-Looking SAR Using Keystone Transform and Optimization NLCS.

    Science.gov (United States)

    Li, Zhongyu; Wu, Junjie; Huang, Yulin; Yang, Haiguang; Yang, Jianyu

    2017-01-23

    Bistatic forward-looking SAR (BFSAR) is a kind of bistatic synthetic aperture radar (SAR) system that can image forward-looking terrain in the flight direction of an aircraft. Until now, BFSAR imaging theories and methods for a stationary scene have been researched thoroughly. However, for moving-target imaging with BFSAR, the non-cooperative movement of the moving target induces some new issues: (I) large and unknown range cell migration (RCM) (including range walk and high-order RCM); (II) the spatial-variances of the Doppler parameters (including the Doppler centroid and high-order Doppler) are not only unknown, but also nonlinear for different point-scatterers. In this paper, we put forward an adaptive moving-target imaging method for BFSAR. First, the large and unknown range walk is corrected by applying keystone transform over the whole received echo, and then, the relationships among the unknown high-order RCM, the nonlinear spatial-variances of the Doppler parameters, and the speed of the mover, are established. After that, using an optimization nonlinear chirp scaling (NLCS) technique, not only can the unknown high-order RCM be accurately corrected, but also the nonlinear spatial-variances of the Doppler parameters can be balanced. At last, a high-order polynomial filter is applied to compress the whole azimuth data of the moving target. Numerical simulations verify the effectiveness of the proposed method.

  15. An Adaptive Moving Target Imaging Method for Bistatic Forward-Looking SAR Using Keystone Transform and Optimization NLCS

    Directory of Open Access Journals (Sweden)

    Zhongyu Li

    2017-01-01

    Full Text Available Bistatic forward-looking SAR (BFSAR is a kind of bistatic synthetic aperture radar (SAR system that can image forward-looking terrain in the flight direction of an aircraft. Until now, BFSAR imaging theories and methods for a stationary scene have been researched thoroughly. However, for moving-target imaging with BFSAR, the non-cooperative movement of the moving target induces some new issues: (I large and unknown range cell migration (RCM (including range walk and high-order RCM; (II the spatial-variances of the Doppler parameters (including the Doppler centroid and high-order Doppler are not only unknown, but also nonlinear for different point-scatterers. In this paper, we put forward an adaptive moving-target imaging method for BFSAR. First, the large and unknown range walk is corrected by applying keystone transform over the whole received echo, and then, the relationships among the unknown high-order RCM, the nonlinear spatial-variances of the Doppler parameters, and the speed of the mover, are established. After that, using an optimization nonlinear chirp scaling (NLCS technique, not only can the unknown high-order RCM be accurately corrected, but also the nonlinear spatial-variances of the Doppler parameters can be balanced. At last, a high-order polynomial filter is applied to compress the whole azimuth data of the moving target. Numerical simulations verify the effectiveness of the proposed method.

  16. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fiaschetti, V., E-mail: fiaschettivaleria@tin.it [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy); Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G. [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy)

    2012-11-15

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  17. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    International Nuclear Information System (INIS)

    Fiaschetti, V.; Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G.

    2012-01-01

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  18. Piling Pills? Forward-Looking Behavior and Stockpiling of Prescription Drugs

    DEFF Research Database (Denmark)

    Simonsen, Marianne; Skipper, Lars; Skipper, Niels

    This paper provides evidence of forward-looking behavior in the demand for prescription drugs, while relying on registry-based, individual-level information about the universe of Danish prescription drug purchases from 1995–2014. We exploit a universal shift in policy in early 2000 from a flat......-rate to a non-linear insurance plan for prescription drugs that incentivizes stockpiling at the end of the coverage year. We extend the original framework of Keeler et al. (1977) and discuss how the institutional features of most health insurance contracts, at least theoretically, incentivize intertemporal...... immediately prior to the end-of-year reset in the non-linear plan using a difference-in-difference strategy. We provide evidence that consumers react to this reset by stockpiling toward the end of the coverage year: consumers buy what amounts to an additional 20%. We detect heterogeneity in the size...

  19. Trends in Correlation-Based Pattern Recognition and Tracking in Forward-Looking Infrared Imagery

    Science.gov (United States)

    Alam, Mohammad S.; Bhuiyan, Sharif M. A.

    2014-01-01

    In this paper, we review the recent trends and advancements on correlation-based pattern recognition and tracking in forward-looking infrared (FLIR) imagery. In particular, we discuss matched filter-based correlation techniques for target detection and tracking which are widely used for various real time applications. We analyze and present test results involving recently reported matched filters such as the maximum average correlation height (MACH) filter and its variants, and distance classifier correlation filter (DCCF) and its variants. Test results are presented for both single/multiple target detection and tracking using various real-life FLIR image sequences. PMID:25061840

  20. Clinical application of low energy intracardiac cardioversion of atrial fibrillation

    International Nuclear Information System (INIS)

    Wu Liqun; Gu Gang; Su Kan; Su Renying; Shen Yongchu; Shen Weifeng

    2002-01-01

    Objective: To evaluate the efficacy and safety of low energy intracardiac cardioversion in persistent atria fibrillation. Methods: Low energy intracardiac cardioversion was performed by delivering R wave-synchronized biphasic shocks in 7 patients (4 men, 3 women) with persistent atrial fibrillation. Prior to the procedure, all patients underwent transesophageal echocardiographic examinations to rule out the presence of intracardiac thrombus and received subcutaneous injection of low molecular weight heparin for 3-5 days. Two custom-made 6 Fr catheters (Rhythm Technologies of Getz, USA) were used for de-fibrillation shock delivery. One catheter was positioned in the lower right atrium so that the majority of the catheter electrodes had firm contact with the right atrial free wall. The second catheter was placed randomly either in coronary sinus through right internal jugular vein or in the left pulmonary artery through femoral vein. In addition, a standard diagnostic 6-F quadrupolar catheter was placed at the right ventricular apex for ventricular synchronization and postshock ventricular pacing. Shocks were delivered by Implant Support Device (Model 4510, Teleceronics). After conversion, all patients were treated with intravenous amiodarone in the first 24 hours followed by oral administration. Results: In all 7 patients cardioversion of atrial fibrillation to sinus rhythm was successfully obtained. A mean of 2 ± 1 shocks per patient has been delivered with a total amount of 13 shocks. The average delivered energy was 7.8 ± 2.2 Joules. No complication occurred. At a mean follow-up of 18 ± 9 months, 4 of the 7 patients treated successfully showed sinus rhythm there after. Atrial fibrillation recurred in 3 patients at the second, fifth day and eighth month after cardioversion. Conclusions: Low energy intracardiac cardioversion is effective and safe, and can be easily performed in patients without general anesthesia. It offers a new option for restoring sinus

  1. Architectural Lessons: Look Back In Order To Move Forward

    Science.gov (United States)

    Huang, T.; Djorgovski, S. G.; Caltagirone, S.; Crichton, D. J.; Hughes, J. S.; Law, E.; Pilone, D.; Pilone, T.; Mahabal, A.

    2015-12-01

    True elegance of scalable and adaptable architecture is not about incorporating the latest and greatest technologies. Its elegance is measured by its ability to scale and adapt as its operating environment evolves over time. Architecture is the link that bridges people, process, policies, interfaces, and technologies. Architectural development begins by observe the relationships which really matter to the problem domain. It follows by the creation of a single, shared, evolving, pattern language, which everyone contributes to, and everyone can use [C. Alexander, 1979]. Architects are the true artists. Like all masterpieces, the values and strength of architectures are measured not by the volumes of publications, it is measured by its ability to evolve. An architect must look back in order to move forward. This talk discusses some of the prior works including onboard data analysis system, knowledgebase system, cloud-based Big Data platform, as enablers to help shape the new generation of Earth Science projects at NASA and EarthCube where a community-driven architecture is the key to enable data-intensive science. [C. Alexander, The Timeless Way of Building, Oxford University, 1979.

  2. 4D ultrasound and 3D MRI registration of beating heart

    International Nuclear Information System (INIS)

    Herlambang, N.; Matsumiya, K.; Masamune, K.; Dohi, T.; Liao, H.; Tsukihara, H.; Takamoto, S.

    2007-01-01

    To realize intra-cardiac surgery without cardio-pulmonary bypass, a medical imaging technique with both high image quality and data acquisition rate that is fast enough to follow heart beat movements is required. In this research, we proposed a method that utilized the image quality of MRI and the speed of ultrasound. We developed a 4D image reconstruction method using image registration of 3D MRI and 4D ultrasound images. The registration method consists of rigid registration between 3D MRI and 3D ultrasound with the same heart beat phase, and non-rigid registration between 3D ultrasound images from different heart beat phases. Non-rigid registration was performed with B-spline based registration using variable spring model. In phantom experiment using balloon phantom, registration accuracy was less than 2 mm for total heart volume variation range of 10%. We applied our registration method on 3D MRI and 4D ultrasound images of a volunteer's beating heart data and confirmed through visual observation that heart beat pattern was well reproduced. (orig.)

  3. Evolutionary technology adoption in an oligopoly market with forward-looking firms

    Science.gov (United States)

    Lamantia, F.; Radi, D.

    2018-05-01

    In this paper, we propose an evolutionary oligopoly game of technology adoption in a market with isoelastic demand and two possible (linear) production technologies. While one technology is characterized by lower marginal costs, the magnitude of fixed costs entails that a technology does not necessarily dominate the other. Firms are forward-looking as they assess the profitability of employing either technology according to the corresponding expected profits. The dynamics of the system is studied through a piecewise-smooth map, for which we present a local stability analysis of equilibria and show the occurrence of smooth and border collision bifurcations. Global analysis of the model is also presented to show the coexistence of attractors and its economic significance. This investigation reveals that firms can fail to learn to adopt the more efficient technology.

  4. Forward-looking report of the electricity supply-demand balance in France. 2011

    International Nuclear Information System (INIS)

    2011-01-01

    After an introduction presenting the objective of this report and the method used for its predictions, this document proposes an analysis of energy consumption: past trends, context of predictions, building up of predictions, global predictions, impact of demand control, comparison with a previous forward-looking assessment, comparison with other scenarios and other European countries. It analyses and discusses power consumption predictions (electricity consumption time variations, load curve evolution perspectives, peak power), production supply (current stock, thermal nuclear, thermal fossil, thermal decentralized, hydroelectric, wind energy, and photovoltaic production), the evolution of the supply-demand balance on a medium term for France and for two French regions. It finally proposes a long term prospective vision regarding energy

  5. Intracardiac heterotopia--mesenchymal and endodermal.

    Science.gov (United States)

    Ariza, S; Rafel, E; Castillo, J A; Garcia-Canton, J A

    1978-01-01

    A case is reported of an intracardiac 'epithelial heterotopia' with a predominant mesenchymal component. This is thought to have resulted from the differentiation of aberrant primitive cell(s) displaced into the heart during its development. Though microscopically resembling a myxoma, this lesion is clearly distinguished by the presence of glandular structures. The myxoid component exhibited a startling invasiveness which resulted in occlusion of the superior vena cava, causing symptoms very early in life and death at the age of 6 months. Images PMID:637987

  6. Object Classification in Semi Structured Enviroment Using Forward-Looking Sonar

    Directory of Open Access Journals (Sweden)

    Matheus dos Santos

    2017-09-01

    Full Text Available The submarine exploration using robots has been increasing in recent years. The automation of tasks such as monitoring, inspection, and underwater maintenance requires the understanding of the robot’s environment. The object recognition in the scene is becoming a critical issue for these systems. On this work, an underwater object classification pipeline applied in acoustic images acquired by Forward-Looking Sonar (FLS are studied. The object segmentation combines thresholding, connected pixels searching and peak of intensity analyzing techniques. The object descriptor extract intensity and geometric features of the detected objects. A comparison between the Support Vector Machine, K-Nearest Neighbors, and Random Trees classifiers are presented. An open-source tool was developed to annotate and classify the objects and evaluate their classification performance. The proposed method efficiently segments and classifies the structures in the scene using a real dataset acquired by an underwater vehicle in a harbor area. Experimental results demonstrate the robustness and accuracy of the method described in this paper.

  7. Incidental enhancing lesions found on preoperative breast MRI: management and role of second-look ultrasound.

    Science.gov (United States)

    Luciani, M L; Pediconi, F; Telesca, M; Vasselli, F; Casali, V; Miglio, E; Passariello, R; Catalano, C

    2011-09-01

    This study prospectively assessed second-look ultrasound (US) for the evaluation of incidental enhancing lesions identified on preoperative breast magnetic resonance imaging (MRI). Between 2004 and 2007, 182 patients with malignant breast lesions detected on US and/or X-ray mammography and confirmed by cytology/histology underwent preoperative breast contrast-enhanced (CE)-MRI. Patients with incidental lesions on breast MRI underwent second-look high-resolution US directed at the site of the incidental finding. Diagnosis of incidental lesions was based on biopsy or 24-month follow-up. Breast MRI detected 55 additional lesions in 46/182 (25.2%) patients. Forty-two of 55 (76.3%) lesions were detected on second-look US in 38/46 (82.6%) patients. Malignancy was confirmed for 24/42 (57.1%) correlate lesions compared with 7/13 (53.8%) noncorrelate lesions. Second-look US depicted 8/9 (88.8%) Breast Imaging Reporting and Data System (BI-RADS) 5, 16/22 (72.7%) BI-RADS 4 and 18/24 (75%) BI-RADS 3 lesions. Sensitivity, specificity, accuracy and positive and negative predictive values for lesion detection/diagnosis was 100%, 88.9%, 94.6%, 90.3% and 100% for MRI and 64.3%, 70.4%, 67.3%, 69.2% and 65.5% for second-look US. Improved performance for US was obtained when masslike lesions only were considered. Second-look US is a confirmatory method for incidental findings on breast MRI, particularly for mass-like lesions.

  8. Successful Management of Tubal Ectopic Pregnancy with Transvaginal Sonography Guided Intracardiac KCL Injection and Systemic Methotrexate - A Case Report

    Directory of Open Access Journals (Sweden)

    Sumesh Choudhary

    2014-01-01

    Full Text Available Background: Methotrexate (Mtx is an accepted modality for conservative treatment of ectopic pregnancy. However, there is no consensus regarding its use in live ectopic pregnancy and high serum beta-human chorionic gonadotrophin (β-hCG titres. Concurrent use of intra-sac hypertonic KCl, to produce cardiac asystole with systemic Mtx potentially improve outcome in live ectopic gestations with very high serum β-hCG titres. Here a successful management of live ectopic pregnancy in a 25-year-old nulliparous woman, with very high β-hCG titres (29502.04mIU/mL, using ultrasound-guided intra-cardiac potassium chloride (KCl injection and systemic Mtx is reported. No treatment related complications were encountered. However, individualized treatment with a stringent follow-up regime is mandatory in such cases.

  9. Systemic and intracardiac hemodynamic disturbance in complicated forms of hepatocirrhosis

    International Nuclear Information System (INIS)

    Mjasnik, B.N.; Chodzibekov, M.C.; Achmedzanova, S.S.

    1990-01-01

    On the base of radionuclide investigation of systemic and intracardiac hemodynamics was shown that the rate of kinetic variants of hemocirculation does not depend on the stage of portal hypertension in complicated forms of hepatocirrhosis. Blood redistribution in these patients creates volumentrical overload of cardiac ventricles and pulmonary circulation, that is conditioned of additional tension of cardiac muscle and especially of right ventricle myocardium, which reserve rapidly ran out. Operations which increase blood shunt from portal system to superior vena cava raise preload of myocardium that makes the high risk in appearance of cardiac insufficiency, especially of right ventricle in early post operative period. The received data indicated on necessity to take into account the state of intracardiac hemodynamics in selection of surgical approach in patients with complicated forms of hepatocirrhosis. (orig.) [de

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... is Abdominal Ultrasound Imaging? What are some common uses of the procedure? How should we prepare for an ultrasound exam? What does the ultrasound equipment look like? How does the procedure work? How is the procedure performed? What will my ...

  11. Girls into Physics--Looking Back and Looking Forward

    Science.gov (United States)

    Thomson, Clare

    2011-01-01

    Girls are under-represented in physics post-16. They continue to make up only 22% of those taking A-level Physics, despite the many changes in the educational system over the last 20 years. This article looks at the work the Institute of Physics has undertaken to address the issue. After outlining the key issues that were identified in work…

  12. Multi-Channel Deconvolution for Forward-Looking Phase Array Radar Imaging

    Directory of Open Access Journals (Sweden)

    Jie Xia

    2017-07-01

    Full Text Available The cross-range resolution of forward-looking phase array radar (PAR is limited by the effective antenna beamwidth since the azimuth echo is the convolution of antenna pattern and targets’ backscattering coefficients. Therefore, deconvolution algorithms are proposed to improve the imaging resolution under the limited antenna beamwidth. However, as a typical inverse problem, deconvolution is essentially a highly ill-posed problem which is sensitive to noise and cannot ensure a reliable and robust estimation. In this paper, multi-channel deconvolution is proposed for improving the performance of deconvolution, which intends to considerably alleviate the ill-posed problem of single-channel deconvolution. To depict the performance improvement obtained by multi-channel more effectively, evaluation parameters are generalized to characterize the angular spectrum of antenna pattern or singular value distribution of observation matrix, which are conducted to compare different deconvolution systems. Here we present two multi-channel deconvolution algorithms which improve upon the traditional deconvolution algorithms via combining with multi-channel technique. Extensive simulations and experimental results based on real data are presented to verify the effectiveness of the proposed imaging methods.

  13. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake and others

    1988-12-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69+-0.48 to 0.11+-0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07+-1.03) were not significantly different from those at the first scintigraphy (1.13+-0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy.

  14. Assessment of warfarin therapy under full dose using indium-111 platelet scintigraphy in patients with intracardiac thrombi

    International Nuclear Information System (INIS)

    Yamada, Makoto; Onishi, Kenji; Fukunami, Masatake

    1988-01-01

    Twenty patients in whom intracardiac thrombi were detected by indium-111 platelet scintigraphy (the first platelet scintigraphy) were prospectively studied to examine the effect of warfarin therapy under full dose on the intracardiac thrombogenecity. Eleven patients (group I) who received 2-6 mg/day of warfarin and 9 patients (group II) who did not received warfarin had the second platelet scintigraphies 14-71 days after the first platelet scintigraphies. In group I, 10 platelet scintigraphies became negative and one remained positive for intracardiac thrombi after administration of warfarin, while in group II 8 platelet scintigraphies remained positive and only one changed to negative. The incidence of negative image at the second platelet scintigraphy was significantly lower in group II than that in group I. In group I, the degree of accumulation of platelets onto the surface of the thrombus (%IE), showed significant reduction (0.69±0.48 to 0.11±0.21) after warfarin therapy, while in group II %IE at the second scintigraphy (1.07±1.03) were not significantly different from those at the first scintigraphy (1.13±0.79). These results indicated that warfarin therapy under full dose inhibited the deposition of platelets on the intracardiac thrombi and thrombogenecity in the patients with intracardiac thrombi which were detected by indium-111 platelet scintigraphy. (author)

  15. Intracardiac thrombus in Behçet's disease: Two case reports

    Directory of Open Access Journals (Sweden)

    Brahem Radhia

    2005-07-01

    Full Text Available Abstract Intracardiac thrombus in Behçet's disease is an extremely rare manifestation. We report two such cases. A 20-year-old man presented with dyspnoea, cough and haemoptysis. Right heart thrombus associated with pulmonary artery aneurysm and thromboembolism was identified by helical CT and transoesophageal echocardiography. The second case was a 29-year-old male admitted for fever and chest pain. A diagnosis of right atrial thrombosis associated with pulmonary embolism and hyperhomocysteinemia was made. Due to the absence of haemodynamic compromise, medical management consisting of immunosupressive and anticoagulation therapy was adopted which resulted in complete dissolution of the thrombus with dramatic clinical improvement in both cases of clinical status. Conclusion intracardiac thrombus is a rare complication of Behçet's disease. As shown in our patients, medical treatment should be considered as the first line.

  16. Intracardiac impedance response during acute AF internal cardioversion using novel rectilinear and capacitor-discharge waveforms.

    Science.gov (United States)

    Rababah, A S; Walsh, S J; Manoharan, G; Walsh, P R; Escalona, O J

    2016-07-01

    Intracardiac impedance (ICI) is a major determinant of success during internal cardioversion of atrial fibrillation (AF). However, there have been few studies that have examined the dynamic behaviour of atrial impedance during internal cardioversion in relation to clinical outcome. In this study, voltage and current waveforms captured during internal cardioversion of acute AF in ovine models using novel radiofrequency (RF) generated low-tilt rectilinear and conventional capacitor-discharge based shock waveforms were retrospectively analysed using a digital signal processing algorithm to investigate the dynamic behaviour of atrial impedance during cardioversion. The algorithm was specifically designed to facilitate the simultaneous analysis of multiple impedance parameters, including: mean intracardiac impedance (Z M), intracardiac impedance variance (ICIV) and impedance amplitude spectrum area (IAMSA) for each cardioversion event. A significant reduction in ICI was observed when comparing two successive shocks of increasing energy where cardioversion outcome was successful. In addition, ICIV and IAMSA variables were found to inversely correlate to the magnitude of energy delivered; with a stronger correlation found to the former parameter. In conclusion, ICIV and IAMSA have been evidenced as two key dynamic intracardiac impedance variables that may prove useful in better understanding of the cardioversion process and that could potentially act as prognostic markers with respect to clinical outcome.

  17. Echogenic intracardiac focus on second trimester ultrasound: prevalence and significance in a Middle Eastern population.

    Science.gov (United States)

    Mirza, Fadi G; Ghulmiyyah, Labib; Tamim, Hani; Bou Hamdan, Farah; Breidy, Juliana; Geagea, Sandra; Usta, Ihab; Adra, Abdallah; Nassar, Anwar H

    2016-01-01

    The association between echogenic intracardiac focus (EIF) and trisomy 21 is well established, with a recognized ethnic variation. Our study aimed to determine the prevalence of EIF in a Middle Eastern population and to examine its association with trisomy 21 and other adverse pregnancy outcomes. Retrospective case-control study of second-trimester obstetric sonograms (16-28 weeks) performed at a tertiary care center over a 5-year period. Cases with EIF were retrieved, and a matched control group with no EIF was identified. The incidence of trisomy 21 and other adverse pregnancy outcomes was compared. A total of 9270 obstetric sonograms were examined, with an EIF prevalence of 2.5% (95% CI: 2.2-2.8%). Of patients with available outcome data, EIF was not associated with trisomy 21 (0/163 versus 1/163; p value = 1.00). Additionally, EIF was not associated with trisomy 18, trisomy 13, small for gestational age, preterm birth, fetal demise, cesarean delivery, operative vaginal delivery, or admission to the neonatal intensive care unit. In a contemporary Middle Eastern population, EIF is a rare occurrence. As an isolated finding, it is not associated with aneuploidy or other adverse pregnancy outcomes. EIF appears to be incidental with no impact on clinical practice.

  18. Anatomical Evidence for Intracardiac Blood Shunting in Marine Turtles

    African Journals Online (AJOL)

    ... suggests that right to left intra-cardiac blood shunts may be a feature of diving in sea turtles; the sphincter providing a mechanism for the control of blood flow through the heart. The comparative anatomy of the pulmonary arteries of selected terrestrial reptiles suggests that a similar mechanism exists in non-diving species.

  19. Intracardiac echocardiography: use during transcatheter device closure of a patent ductus arteriosus in a dog.

    Science.gov (United States)

    Chetboul, V; Damoiseaux, C; Behr, L; Morlet, A; Moise, N S; Gouni, V; Lavennes, M; Pouchelon, J-L; Laborde, F; Borenstein, N

    2017-06-01

    Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Clinical evaluation of the use of an intracardiac electrocardiogram to guide the tip positioning of peripherally inserted central catheters.

    Science.gov (United States)

    Zhao, Ruiyi; Chen, Chunfang; Jin, Jingfen; Sharma, Komal; Jiang, Nan; Shentu, Yingqin; Wang, Xingang

    2016-06-01

    The use of peripherally inserted central catheters (PICCs) provides important central venous accesses for clinical treatments, tests and monitoring. Compared with the traditional methods, intracardiac electrocardiogram (ECG)-guided method has the potential to guide more accurate tip positioning of PICCs. This study aimed to clinically evaluate the effectiveness of an intracardiac ECG to guide the tip positioning by monitoring characteristic P-wave changes. In this study, eligible patients enrolled September 2011 to May 2012 according to the inclusion and exclusion criteria received the catheterization monitored by intracardiac ECG. Then chest radiography was performed to check the catheter position. The results revealed that, with 117 eligible patients, all bar one patient who died (n = 116) completed the study, including 60 males and 56 females aged 51.2 ± 15.1 years. Most (n = 113, > 97%) had characteristic P-wave changes. The intracardiac ECG-guided positioning procedure achieved correct placement for 112 patients (96.56%), demonstrating 99.12% sensitivity and 100% specificity. In conclusion, the intracardiac ECG can be a promising technique to guide tip positioning of PICCs. However, since the sample size in this study is limited, more experience and further study during clinical practice are needed to demonstrate achievement of optimal catheterization outcomes. © 2015 John Wiley & Sons Australia, Ltd.

  1. Moving Forward - Progress on Forward Detectors

    CERN Multimedia

    Grafstrom, P.

    2006-01-01

    You might have been sitting in some meeting hearing about the ATLAS forward detectors. Coming back to your office wanting to learn more you look in the ATLAS TDR’s and disappointingly you find nothing about forward detectors. The explanation is of course that the forward detectors are newcomers in the ATLAS detector arsenal. ATLAS is designed to measure high Pt particles with pseudo rapidities up to 5 which in terms of angles means angles bigger than one degree (0.8 degree to be more accurate). Particles produced with smaller angles close to the beam escape detection. The hole in the forward direction will now partly be filled. Several new detectors have recently been proposed. These detectors are designed for various luminosity measurements but they also have a physics potential in themselves. Closest to the IP there is LUCID (LUminosity measurement using Cerenkov Integrating Detector). LUCID comprises some 170 Cerenkov tubes sitting around the beam pipe at about 17 m away from the IP. The tubes are 1.5 ...

  2. Forward-looking farmers owning multiple potential wetland restoration sites: implications for efficient restoration

    Science.gov (United States)

    Schroder (Kushch), Svetlana; Lang, Zhengxin; Rabotyagov, Sergey

    2018-04-01

    Wetland restoration can increase the provision of multiple non-market ecosystem services. Environmental and socio-economic factors need to be accounted for when land is withdrawn from agriculture and wetlands are restored. We build multi-objective optimization models to provide decision support for wetland restoration in the Le Sueur river watershed in Southern Minnesota. We integrate environmental objectives of sediment reduction and habitat protection with socio-economic factors associated with the overlap of private land with potential wetland restoration sites in the watershed and the costs representing forward-looking farmers voluntarily taking land out of agricultural production in favor of wetland restoration. Our results demonstrate that the inclusion of these factors early on in the restoration planning process affects both the total costs of the restoration project and the spatial distribution of optimally selected wetland restoration sites.

  3. Volumetric real-time imaging using a CMUT ring array.

    Science.gov (United States)

    Choe, Jung Woo; Oralkan, Ömer; Nikoozadeh, Amin; Gencel, Mustafa; Stephens, Douglas N; O'Donnell, Matthew; Sahn, David J; Khuri-Yakub, Butrus T

    2012-06-01

    A ring array provides a very suitable geometry for forward-looking volumetric intracardiac and intravascular ultrasound imaging. We fabricated an annular 64-element capacitive micromachined ultrasonic transducer (CMUT) array featuring a 10-MHz operating frequency and a 1.27-mm outer radius. A custom software suite was developed to run on a PC-based imaging system for real-time imaging using this device. This paper presents simulated and experimental imaging results for the described CMUT ring array. Three different imaging methods--flash, classic phased array (CPA), and synthetic phased array (SPA)--were used in the study. For SPA imaging, two techniques to improve the image quality--Hadamard coding and aperture weighting--were also applied. The results show that SPA with Hadamard coding and aperture weighting is a good option for ring-array imaging. Compared with CPA, it achieves better image resolution and comparable signal-to-noise ratio at a much faster image acquisition rate. Using this method, a fast frame rate of up to 463 volumes per second is achievable if limited only by the ultrasound time of flight; with the described system we reconstructed three cross-sectional images in real-time at 10 frames per second, which was limited by the computation time in synthetic beamforming.

  4. Intra-cardiac echocardiography guided catheter ablation of a right posterior accessory pathway in a patient with Ebstein׳s anomaly

    Directory of Open Access Journals (Sweden)

    Akira Shimane, MD

    2014-12-01

    Full Text Available We report a case of Ebstein׳s anomaly in which radiofrequency catheter ablation of an accessory pathway was successfully performed under intra-cardiac echocardiography. A 50-year-old woman was referred to our hospital for radiofrequency catheter ablation of a paroxysmal supraventricular tachycardia. A 12-lead surface electrocardiogram revealed ventricular pre-excitation associated with type B Wolff–Parkinson–White syndrome. In the baseline electrophysiological study, an orthodromic atrioventricular reciprocating tachycardia with a right posterior accessory pathway was induced. A phased-array intra-cardiac echo probe was positioned in the right atrium to visualize the atrioventricular junction. The key structures for catheter ablation, such as the atrialized right ventricle, atrioventricular junction, and tricuspid valve, were clearly visualized on intra-cardiac echocardiography. Radiofrequency current was successfully delivered at the atrioventricular junction, where a Kent potential was recorded. During a 6-month follow-up period, the patient was free from arrhythmias. The findings in this case suggest that phased-array intra-cardiac echocardiography is useful for ablation of right-sided accessory pathways in patients with Ebstein׳s anomaly.

  5. Intracardiac Thrombosis during Adult Liver Transplantation

    Directory of Open Access Journals (Sweden)

    Marina Moguilevitch

    2013-01-01

    Full Text Available Intracardiac thrombosis (ICT and pulmonary embolism (PE during adult liver transplantation are rare but potentially lethal complications. They are often overlooked because of significant diagnostic challenges. The combination of hemodynamic compromise and transesophageal echocardiography (TEE findings allows for correct diagnosis. A large variety of putative risk factors for ICT and PE have been suggested, but these events are considered to be multifactorial. There are different proposed treatment modalities for these devastating complications. Unfortunately, in spite of growing knowledge in this area, intraoperative and postoperative mortalities remain very high. The retrospective nature of the study of these events makes the case reports extremely valuable.

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite ... display screen that looks like a computer or television monitor. The image is created based on the ...

  7. Mutations in plant breeding: a glance back and a look forward

    International Nuclear Information System (INIS)

    Gustafsson, A.

    1975-01-01

    This brief retrospect of previous shortcomings and procedures really indicates the need for a better co-ordination and co-operation in plant breeding. We now know which mutagens are essential in practical mutation work, and we include radiations as well as chemicals. We now know that there is no principal difference between natural and induced variation. We can easily induce mutational events covering the gap between gross chromosomal rearrangements and DNA-base substitutions. We also know that induced variation may in the future fill and replace the loss of natural variability, or may even extend the limits of variation. We know that mutation and recombination--as evidenced, for instance, by the successful work in barley--will be united into routine procedures, also leading to new breakthroughs in plant improvement. Moreover, ingenious techniques of mass testing are under way, combining traditional and prospective ideas. The mutation method has come to stay, not alone but with gene recombination, with heterosis and with polyploidy. We say that the present is the past's future. To glance back is then to look forward; failures give rise to progress. A synthesis of breeding methods is around the corner

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is Pelvic Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  9. Intracardiac echo-facilitated 3D electroanatomical mapping of ventricular arrhythmias from the papillary muscles: assessing the 'fourth dimension' during ablation.

    Science.gov (United States)

    Proietti, Riccardo; Rivera, Santiago; Dussault, Charles; Essebag, Vidal; Bernier, Martin L; Ayala-Paredes, Felix; Badra-Verdu, Mariano; Roux, Jean-François

    2017-01-01

    Ventricular arrhythmias (VA) originating from a papillary muscle (PM) have recently been described as a distinct clinical entity with peculiar features that make its treatment with catheter ablation challenging. Here, we report our experience using an intracardiac echo-facilitated 3D electroanatomical mapping approach in a case series of patients undergoing ablation for PM VA. Sixteen patients who underwent catheter ablation for ventricular tachycardia (VT) or symptomatic premature ventricular contractions originating from left ventricular PMs were included in the study. A total of 24 procedures (mean 1.5 per patient) were performed: 15 using a retrograde aortic approach and 9 using a transseptal approach. Integrated intracardiac ultrasound for 3D electroanatomical mapping was used in 15 of the 24 procedures. The posteromedial PM was the most frequent culprit for the clinical arrhythmia, and the body was the part of the PM most likely to be the successful site for ablation. The site of ablation was identified based on the best pace map matching the clinical arrhythmia and the site of earliest the activation. At a mean follow-up of 10.5 ± 7 months, only two patients had recurrent arrhythmias following a repeat ablation procedure. An echo-facilitated 3D electroanatomical mapping allows for real-time creation of precise geometries of cardiac chambers and endocavitary structures. This is useful during procedures such as catheter ablation of VAs originating from PMs, which require detailed representation of anatomical landmarks. Routine adoption of this technique should be considered to improve outcomes of PM VA ablation. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  10. Looking Forward (Editorial

    Directory of Open Access Journals (Sweden)

    Denise Koufogiannakis

    2009-03-01

    Full Text Available This issue marks the start of EBLIP’s fourthyear of publication. I am excited to begin my new role as Editor-in-Chief at a time when the journal is functioning well and the Editorial Team has a sufficient amount of experience to confidently manage the publishing process, but is young enough to be open to new ideas and make changes without too much angst. Mostly, I hope that the journal can quickly respond to the needs of our readers, authors, and everyone who works to make the journal a success. I am always pleasantly surprised when we put out calls for volunteer help and are overwhelmed with the number of people who are interested in contributing to the journal. I definitely believe that the more people who are involved, the better the end result will be, since more ideas and points of view only strengthen the quality of our endeavour.To kick off this first issue of 2009, we debut a new section called Using Evidence in Practice. This section features brief reports of LIS practitioners' use of evidence to assist with decision making. We hope that this section will attract all the practitioners out there who are trying to incorporate evidence into their daily practice, and want to share some of their successes or struggles with the evidence-based process. The section follows a structured format, so that readers can always expect to be provided with information on a project that includes an overview of the setting, problem, evidence that was used, how change was implemented, the outcome of those changes,and the author’s reflections on trying to implement change by using evidence. I hope these brief reports of “real-life” stories inspire and provide ideas for our readers. Our first article in this section looks at one library’s exploration of the use of folksonomy tags and what the evidence they gathered might mean for the cataloguing of their electronic dissertations and theses collection.I am pleased to announce that we have a new

  11. Statements and presentations from the international conference 'Chernobyl: Looking back to go forwards'

    International Nuclear Information System (INIS)

    2005-01-01

    The Chernobyl Forum has involved representatives of the governments of the affected region, who have been dealing with the social and economic aspects of the accident, and scientists who have experience in evaluating the health and environmental aspects of the accident. There has been a great desire to look back at the experience of the past two decades and then to continue forward in positive and effective ways to improve the health and economic well being of the residents of the three countries. We desperately need to reach consensus on this to make useful and sensible progress in dealing with the issues of the accident that still remain and that require and demand continued attention. It is hoped that the Chernobyl Forum can contribute in a positive way to achieve consensus on disputed issues, to promote public understanding and to make realistic suggestions to help alleviate the lingering consequences of the accident

  12. Looking Back, Looking Forward in Stakeholder Engagement. 10-year Anniversary Colloquium of the FSC, 15 September, OECD Conference Centre, Paris

    International Nuclear Information System (INIS)

    Pescatore, Claudio; Buser, Marcos; Kallenbach-Herbert, Beate; Brazier, David; Molina, Mariano; Blom, Catharina; Simic, Eva; Coadou, Jean; ); Beule, Karina de; Kotra, Janet P.; LE BARS, Yves; Gonzalez Hermosilla, Fernando; Heriard Dubreuil, Gilles; Zeleznik, Nadja; O'Connor, Martin; Lezaun, Javier; Hietanen, Leena; Koivisto, Katarina; Gas, Serge; Mathieu Carey; Massart, Cecile

    2010-01-01

    in nuclear matters (J. Coadou); 13 - Main achievements on the Transparency of Nuclear Regulatory activities (K. de Beule); 14 - European Nuclear Safety Regulators Group (ENSREG); 15 - Celebrating 10 Years of Learning From Stakeholders and Each Other (J.P. Kotra); 16 - Looking back into the past: the first five years of FSC (Y. Le Bars); 17 - An archived site for alpha beta gamma 1994-2009 (C. Massart); 18 - FSC lessons: Are they specific to RWM? (F.G. Hermosilla); 19 - FSC on the Fence (FSC); 20 - Inclusive Governance of RWM, Is it here? How far does it reach? (G. Heriard Dubreuil); 21 - Local partnerships - vain experiment or a way to sustainable participation? (N. Zeleznik); 22 - Confidence: forms and foundations (O'Connor, M.); 23 - The FSC - A Host Country's Perspective - Canada 2002 (Natural Resources Canada); 24 - 'Surfing the FSC' (J. Lezaun); 25 - Looking Back, Looking Forward in Stakeholder Engagement. Forward-looking perspectives from the day's discussions and presentations (B. Kallenbach-Herbert); 26 - Seeking Transparency, FSC Discussion Comments (FSC); 27 - 'Secrets of radiation', Journalist training course at STUK (L. Hietanen); 28 - STUK's course for Journalists, A participant's experience and evaluation (K. Koivisto); 29 - The OECD Nuclear Energy Agency, the Media and the Civil society (S. Gas); 30 - The World's Nuclear Communication Network, 'Media Needs in an International Context' (M. Carey); 31 - Vision for the Reims conference, 14-17 December 2010 (NEA-RWMC); 32 - ICGR 2011 in Japan, 'National Commitment - Regional/Local Confidence' Reflecting 4. Planning Meeting (NUMO)

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Send us your feedback Did you find the information you were looking for? Yes No Please type your comment or suggestion ... General ultrasound procedure View full size with caption Pediatric ...

  14. Fluid mechanics of blood flow in human fetal left ventricles based on patient-specific 4D ultrasound scans.

    Science.gov (United States)

    Lai, Chang Quan; Lim, Guat Ling; Jamil, Muhammad; Mattar, Citra Nurfarah Zaini; Biswas, Arijit; Yap, Choon Hwai

    2016-10-01

    The mechanics of intracardiac blood flow and the epigenetic influence it exerts over the heart function have been the subjects of intense research lately. Fetal intracardiac flows are especially useful for gaining insights into the development of congenital heart diseases, but have not received due attention thus far, most likely because of technical difficulties in collecting sufficient intracardiac flow data in a safe manner. Here, we circumvent such obstacles by employing 4D STIC ultrasound scans to quantify the fetal heart motion in three normal 20-week fetuses, subsequently performing 3D computational fluid dynamics simulations on the left ventricles based on these patient-specific heart movements. Analysis of the simulation results shows that there are significant differences between fetal and adult ventricular blood flows which arise because of dissimilar heart morphology, E/A ratio, diastolic-systolic duration ratio, and heart rate. The formations of ventricular vortex rings were observed for both E- and A-wave in the flow simulations. These vortices had sufficient momentum to last until the end of diastole and were responsible for generating significant wall shear stresses on the myocardial endothelium, as well as helicity in systolic outflow. Based on findings from previous studies, we hypothesized that these vortex-induced flow properties play an important role in sustaining the efficiency of diastolic filling, systolic pumping, and cardiovascular flow in normal fetal hearts.

  15. A Case of Myopathy, Encephalopathy, Lactic Acidosis and Stroke-Like Episodes (MELAS) Syndrome with Intracardiac Thrombus [corrected].

    Science.gov (United States)

    Joo, Jung-Chul; Seol, Myung Do; Yoon, Jin Won; Lee, Young Soo; Kim, Dong-Keun; Choi, Yong Hoon; Ahn, Hyo Seong; Cho, Wook Hyun

    2013-03-01

    Myopathy, encephalopathy, lactic acidosis and stroke-like episodes (MELAS) is a multisystem clinical syndrome manifested by mitochondrial myopathy, encephalopathy, lactic acidosis and recurrent stroke-like episodes. A 27-year-old female with MELAS syndrome presented with cerebral infarction. Echocardiography revealed a thrombus attached to the apex of the hypertrophied left ventricle, with decreased systolic function. The embolism of the intracardiac thrombus might have been the cause of stroke. There should be more consideration given to the increased possibility of intracardiac thrombus formation when a MELAS patient with cardiac involvement is encountered.

  16. Ultrasound in sports medicine-A critical evaluation

    International Nuclear Information System (INIS)

    Allen, Gina M.; Wilson, David J.

    2007-01-01

    This article will discuss the aspects of sports medicine where ultrasound imaging has advantages when compared to MRI looking at the strengths and weaknesses of ultrasound in the context of diagnosis and management. It will also assess the use of ultrasound in therapy including guided injections and current thoughts on novel forms of treatment. We will particularly emphasise the role of ultrasound imaging in the management of injuries of tendon, ligament and muscle

  17. Molecules after 20 Years—Looking Back and Looking Forward

    Directory of Open Access Journals (Sweden)

    Derek J. McPhee

    2015-01-01

    Full Text Available Twenty years—a long time—so what happens after 20 years? Well if you live in New Zealand, according to [1], if you are adopted you can apply to Births, Deaths and Marriages for a copy of your birth certificate to find the names of your birth parents, you can apply to adopt a child who is related to you and you can gamble or work in a casino [1], but more seriously, our 20th anniversary is an appropriate time to look back at the history of Molecules and perhaps offer some speculations about its future.[...

  18. An international multicenter study comparing arrhythmia prevalence between the intracardiac lateral tunnel and the extracardiac conduit type of Fontan operations.

    Science.gov (United States)

    Balaji, Seshadri; Daga, Ankana; Bradley, David J; Etheridge, Susan P; Law, Ian H; Batra, Anjan S; Sanatani, Shubayan; Singh, Anoop K; Gajewski, Kelly K; Tsao, Sabrina; Singh, Harinder R; Tisma-Dupanovic, Svjetlana; Tateno, Shigeru; Takamuro, Motoki; Nakajima, Hiromichi; Roos-Hesselink, Jolien W; Shah, Maully

    2014-08-01

    The study objective was to determine whether the extracardiac conduit Fontan confers an arrhythmia advantage over the intracardiac lateral tunnel Fontan. This multicenter study of 1271 patients compared bradyarrhythmia (defined as need for pacing) and tachyarrhythmia (defined as needing antiarrhythmic therapy) between 602 patients undergoing the intracardiac Fontan and 669 patients undergoing the extracardiac Fontan. The median age at the time of the Fontan procedure was 2.1 years (interquartile range, 1.6-3.2 years) for the intracardiac group and 3.0 years (interquartile range, 2.4-3.9) for the extracardiac group (P 30 days) bradyarrhythmia occurred in 105 patients (18%) in the intracardiac group and 63 patients (9%) in the extracardiac group (P 30 days) tachyarrhythmia occurred in 58 patients (10%) in the intracardiac group and 23 patients (3%) in the extracardiac group (P factoring time since surgery, more patients in the extracardiac group had early bradycardia (odds ratio, 2.9; 95% confidence interval, 1.8-4.6), with no difference in early tachycardia, late bradycardia, or late tachycardia. Overall arrhythmia burden is similar between the 2 groups, but the extracardiac Fontan group had a higher incidence of early bradyarrhythmias. There was no difference in the incidence of late tachyarrhythmias over time between the 2 operations. Therefore, the type of Fontan performed should be based on factors other than an anticipated reduction in arrhythmia burden from the extracardiac conduit. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... is General Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  20. An unexpected complication of acute pancreatitis: Intra-cardiac thrombus.

    Science.gov (United States)

    Keskin, Muhammed; Gümüşdağ, Ayça; Börklü, Edibe Betül; Dayı, Şennur Ünal; Avcı, İlhan İlker; Güvenç, Tolga Sinan; Güngör, Barış; Karabay, Can Yücel; Kozan, Ömer

    2017-05-01

    Left atrial thrombus after acute pancreatitis (AP) is a rare clinical statement. Because of induction of systemic prothrombotic process by AP; some patients with underlying risk factors may develop an intra-cardiac thrombus. We present a 53years-old-woman with moderate mitral stenosis and atrial fibrillation. However the patient was under warfarin treatment, she developed a big left atrial big thrombus which was originated from left atrial appendage after she was suffered from AP. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Intracardiac thrombus in Behçet’s disease

    Directory of Open Access Journals (Sweden)

    I. Ben Ghorbel

    2016-12-01

    Full Text Available Behçet’s disease (BD is a multisystem inflammatory disorder. Intracardiac thrombus (ICT formation is an uncommon but important complication of BD. Of the cases of Behçet’s disease, we selected those with ICT. All patients fulfilled the diagnostic criteria of the International Study Group of Behçet’s disease. The ICT in each case was confirmed by ultrasonography, computed tomography and MRI. Clinical features and laboratory parameters were determined. Among our 518 patients with BD, 8 were diagnosed as having intracardiac thrombus (ICT. All were male; the mean age at the time of the ICT diagnosis was 30.8 years. The main presenting symptoms were hemoptysis, chest pain, and dyspnea. It was associated with pulmonary artery aneurysm and vena cava thrombosis in 3 cases each, pulmonary embolism, and lower limbs deep venous thrombosis in 1 case each. The coexistence of other cardiac complications was as follows: pericarditis in 2 cases, myocarditis, endomyocardial fibrosis, and coronary arteritis with consequent myocardial infarction in one case each. In all cases, echocardiography was sufficient to reach the diagnosis. Chest computed tomography performed in all cases led to the diagnosis of associated pulmonary vasculo-Behçet lesions in 4 cases. All patients received colchicine, anticoagulation, and corticosteroids. Seven patients were on immunosuppressant agents (2 patients received azathioprine and 5 cyclophosphamide. Clinical remission with ICT resolution was observed in 5 cases. Combined immunosuppressive therapy with prednisone and cyclophosphamide might be needed to treat ICT due to BD.

  2. Detection of intra-cardiac and intra-arterial thrombi using labelled platelets

    International Nuclear Information System (INIS)

    Bernard, P.J.; Laforte, C. de

    1990-01-01

    Scintigraphy with 111 Indium labelled platelets is a powerful tool to detect platelet deposits in vessels. This quantitative and functional imaging method needs a labeling procedure which completely preserves the properties of the platelets and allows the concept of hematologically active clot. Three main groups of patients were examined. 1-91 hematologically active intra-cardiac thrombi were detected. The follow-up of 19 of them shows 5 deaths and 7 cerebral embolisms. 2-372 patients with lower limb ischemia, mainly in the case of blue toe syndrome were examined. 158 times a comparison with the surgical patterns was possible, there were 3 false positive and 9 false negative results. 3-In a group of 310 patients with transient cerebro-vascular accidents, 38 times the records were poorly significant. In 27 patients we were able to compare the morphological examinations (including platelet scintigraphy) to the anatomical findings. Sensitivity was only 64% and specificity 71%. As in the cases of intra-cardiac thrombi, the method allows the follow-up of pharmacological therapy. Platelets labelled with 111 Indium provide the means for sensitive and specific detection of hematologically active clots in cardiac and arterial pathology [fr

  3. Detection of intracardiac thrombi by scintiphotography with 111In-labeled autologous platelets

    International Nuclear Information System (INIS)

    Yui, Tokuo; Uchida, Tatsumi; Matsuda, Shin

    1982-01-01

    Detection of intracardiac thrombi by scintigraphy with In-111-oxine labeled autologous platelets was studied in 14 patients with various heart diseases. The results of platelet scintigraphy were compared with those of two dimensional echocardiography. In 4 of the 14 patients, the findings on platelet scintigraphy and echocardiography were both positive. Left atrial thrombi were detected in 3 patients with mitral valve disease (MVD), and left ventricular thrombus in a patient with myocardial infarction with left ventricular aneurysm (MI). The scintigraphy after antiplatelet therapy in the patient with MI did not show any radioactivity on the thrombus. In one of the 14 patients with MVD, the finding on platelet scintigraphy was positive, on the other hand echocardiography was negative. In one of the 14 patients with MVD, the finding on platelet scintigraphy was negative, on the other hand that on echocardiography was positive. The thrombus in this case may be hematologically nonactive thrombus. In-111 platelet scintigraphy is considered to be an excellent method for the diagnosis and in vivo assessment of antithrombotic therapy on intracardiac thrombosis. (J.P.N.)

  4. Coronary artery stent mimicking intracardiac thrombus on cardiac magnetic resonance imaging due to signal loss

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Vejlstrup, Niels Grove; Ahtarovski, Kiril Aleksov

    2012-01-01

    Since the introduction of percutaneous coronary intervention for coronary artery disease, thousands of patients have been treated with the implantation of coronary stents. Moreover, several of the patients with coronary stent undergo cardiac magnetic resonance (CMR) imaging every year. This case...... report is of a 77-year-old man who was previously treated with the implantation of a coronary stent in the left circumflex artery. He underwent CMR imaging, which revealed a process 14×21 mm in the left atrium. Cardiac contrast computed tomography did not demonstrate any cardiac pathology. While...... the signal loss on MRI associated with implanted metallic devices is known, we report a case where an implanted coronary stent in the left circumflex artery led to an intracardiac signal loss mimicking intracardiac thrombus/tumor....

  5. Intracardiac electrocardiographic assessment of precordial TASER shocks in human subjects: A pilot study.

    Science.gov (United States)

    Stopyra, Jason P; Winslow, James E; Fitzgerald, David M; Bozeman, William P

    2017-11-01

    Case reports of cardiac arrest in temporal proximity to Conducted Electrical Weapon(CEW) exposure raise legitimate concerns about this as a rare possibility. In this pilot study, we respectfully navigate the oversight and regulatory hurdles and demonstrate the intra-shock electrocardiographic effects of an intentional transcardiac CEW discharge using subcutaneous probes placed directly across the precordium of patients with a previously implanted intracardiac EKG sensing lead. Adults scheduled to undergo diagnostic EP studies or replacement of an implanted cardiac device were enrolled. Sterile subcutaneous electrodes were placed at the right sternoclavicular junction and the left lower costal margin at the midclavicular line. A standard police issue TASER Model X26 CEW was attached to the subcutaneous electrodes and a 5 s discharge was delivered. Continuous surface and intracardiac EKG monitoring was performed. A total of 157 subjects were reviewed for possible inclusion and 21 were interviewed. Among these, 4 subjects agreed and completed the study protocol. All subjects tolerated the 5 s CEW discharge without clinical complications. There were no significant changes in mean heart rate or blood pressure. Interrogation of the devices after CEW discharge revealed no ventricular pacing, dysrhythmias, damage or interference with the implanted devices. In this pilot study, we have successfully navigated the regulatory hurdles and demonstrated the feasibility of performing intracardiac EKG recording during intentional precordial CEW discharges in humans. While no CEW-associated dysrhythmias were noted, the size of this preliminary dataset precludes making conclusions about the risk of such events. Larger studies are warranted and should consider exploring variations of the CEW electrode position in relation to the cardiac silhouette. Copyright © 2017. Published by Elsevier Ltd.

  6. Real-time data for estimating a forward-looking interest rate rule of the ECB.

    Science.gov (United States)

    Bletzinger, Tilman; Wieland, Volker

    2017-12-01

    The purpose of the data presented in this article is to use it in ex post estimations of interest rate decisions by the European Central Bank (ECB), as it is done by Bletzinger and Wieland (2017) [1]. The data is of quarterly frequency from 1999 Q1 until 2013 Q2 and consists of the ECB's policy rate, inflation rate, real output growth and potential output growth in the euro area. To account for forward-looking decision making in the interest rate rule, the data consists of expectations about future inflation and output dynamics. While potential output is constructed based on data from the European Commission's annual macro-economic database, inflation and real output growth are taken from two different sources both provided by the ECB: the Survey of Professional Forecasters and projections made by ECB staff. Careful attention was given to the publication date of the collected data to ensure a real-time dataset only consisting of information which was available to the decision makers at the time of the decision.

  7. The Role of Echocardiography and Intracardiac Exploration in the Evaluation of Candidacy for Biventricular Repair in Patients With Borderline Left Heart Structures.

    Science.gov (United States)

    Mery, Carlos M; Nieto, R Michael; De León, Luis E; Morris, Shaine A; Zhang, Wei; Colquitt, John L; Adachi, Iki; Kane, Lauren C; Heinle, Jeffrey S; McKenzie, E Dean; Fraser, Charles D

    2017-03-01

    Predictors for single ventricle palliation (SVP) or successful biventricular repair (BVR) in patients with borderline left-side heart structures are not well defined. The goal was to evaluate the role of echocardiography and intracardiac exploration in determining feasibility of BVR. All neonates surgically treated from 1995 to 2015 with mitral valve (MV), aortic valve, or left ventricle end-diastolic dimension z score of -2 or less for whom management was controversial were included. Data were analyzed using Fisher's exact test, Kruskal-Wallis test, and Kaplan-Meier analysis. The cohort consisted of 42 patients: 7 SVP (17%) and 35 BVR (83%). Median follow-up was 7 years (range, 6 months to 18 years). Intracardiac exploration was performed in 29 patients (69%). There was poor correlation between echocardiographic and intraoperative MV measurements (intraclass correlation coefficient 0.14). Preoperative echocardiography significantly underestimated MV size in 14 patients (54%). Two BVR patients were converted to SVP, and 4 (including 1 converted patient) had cardiac-related deaths. All patients with MV greater than 8 mm on preoperative echocardiography had successful BVR. An intraoperative MV less than 8 mm and an abnormal subvalvar apparatus was present in 5 of 6 SVP (83%) and 3 of 3 (100%) failed BVR patients who had intracardiac exploration, and in only 1 of 20 successful BVR patients (5%) who had an intracardiac exploration. The decision to proceed to BVR in patients with borderline left-side heart structures should not rely strictly on echocardiographic measurements. Intracardiac exploration of the MV and subvalvar apparatus is useful before committing a patient to SVP. Patients with low MV z scores, especially those with a normal subvalvar apparatus, may undergo BVR with good outcomes. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Intracardiac tumor: A risk factor for stroke in the young –A case report

    African Journals Online (AJOL)

    Intracardiac mass should be considered a possible risk factor for ischemic stroke in young adult, especially in the absence of other risk factors such as connective tissue disorders, HIV/AIDS, hemoglobinopathy or use of recreational drugs. High index of suspicion is required in order not to overlook such source of emboli.

  9. Intracardiac Low-grade Sarcoma Following Treatment for Ewing Sarcoma.

    Science.gov (United States)

    Ortiz, Michael V; Magnan, Heather; Slotkin, Emily K; Ambati, Srikanth R; Chou, Alexander J; Wexler, Leonard H; Meyers, Paul A; Walsh, Michael F; Heaton, Todd; Girardi, Leonard N; Wolden, Suzanne L; Price, Anita P; Kennedy, Jennifer A; Zehir, Ahmet; Hameed, Meera; Berger, Michael F; Kentsis, Alex; Shukla, Neerav

    2017-11-01

    A 16-year-old male was diagnosed with Ewing sarcoma of the ribcage with pulmonary metastases. Six months after completion of scheduled therapy, he was found to have a new intracardiac mass, presumed recurrent Ewing sarcoma. EWSR1 fusion was not detected by droplet digital polymerase chain reaction from blood plasma. After no improvement with salvage chemotherapy, he underwent surgical resection that identified a low-grade spindle cell sarcoma. Despite the near-synchronous presentation of 2 unrelated sarcomas, extensive genomic analyses did not reveal any unifying somatic or germline mutations nor any apparent cancer predisposition. This case also highlights the potential role of utilizing plasma cell-free DNA for diagnosing tumors in locations where biopsy confers high morbidity.

  10. Identification of intracardiac thrombi in stroke patients with indium-111 platelet scintigraphy

    International Nuclear Information System (INIS)

    Kessler, C.; Henningsen, H.; Reuther, R.; Kimmig, B.; Roesch, M.

    1987-01-01

    Platelet scintigraphy (PSC) with indium-111 labelled platelets has been confirmed as an adequate method for the detection of intracardiac thrombi in patients with heart disease. We performed PSC of the heart and the neck vessels in 27 stroke patients with suspected cardiac embolism and as control on 10 patients with atherosclerotic lesions of the carotid arteries without evidence of heart disease. The carotid PSC was positive in 6 of 10 patients with carotid disease, and twice in the 27 with suspected cardiac embolism. In these 27 the PSC of the heart indicated pathological conditions 13 times. Pathological platelet accumulations could be visualized in 3 cases in the atrial space, in 9 cases in the region of the left ventricle, and once at the aortic valve. Scintigraphy was negative in all 10 patients with atherosclerosis of the neck vessels. The two-dimensional echocardiography revealed pathological findings in 8 of the 13 patients with positive heart PSC (3 with intraventricular thrombi, 3 with valvular disease, 2 with decreased ventricular contractility) and was normal in the 10 control patients. Open-heart surgery was performed in 2 patients with pathological PSC and revealed an intracardiac thrombus. Three of 4 patients with positive atrial PSC showed mitral or aortic valve disease. These results suggest that PSC can provide a valuable method for detecting cardiac thrombi in stroke patients

  11. Intracardiac Echocardiography Guided Transeptal Catheter Injection of Microspheres for Assessment of Cerebral Microcirculation in Experimental Models

    Directory of Open Access Journals (Sweden)

    Judith Bellapart

    2013-01-01

    Full Text Available The use of microspheres for the determination of regional microvascular blood flow (RMBF has previously used different approaches. This study presents for the first time the intracardiac injection of microspheres using transeptal puncture under intracardiac echocardiography guidance. Five Merino sheep were instrumented and cardiovascularly supported according to local guidelines. Two catheter sheaths into the internal jugular vein facilitated the introduction of an intracardiac probe and transeptal catheter, respectively. Five million colour coded microspheres were injected into the left atrium via this catheter. After euthanasia the brain was used as proof of principle and the endpoint for determination of microcirculation at different time points. Homogeneous allocation of microspheres to different regions of the brain was found over time. Alternate slices from both hemispheres showed the following flow ranges: for slice 02; 0.57–1.02 mL/min/g, slice 04; 0.45–1.42 mL/min/g, slice 06; 0.35–1.87 mL/min/g, slice 08; 0.46–1.77 mL/min/g, slice 10; 0.34–1.28 mL/min/g. A mixed effect regression model demonstrated that the confidence interval did include zero suggesting that the apparent variability intra- and intersubject was not statistically significant, supporting the stability and reproducibility of the injection technique. This study demonstrates the feasibility of the transeptal injection of microspheres, showing a homogeneous distribution of blood flow through the brain unchanged over time and has established a new interventional model for the measurement of RMBF in ovine models.

  12. Intracardiac echocardiography to diagnose pannus formation after aortic valve replacement.

    Science.gov (United States)

    Yamamoto, Yoshiya; Ohara, Takahiro; Funada, Akira; Takahama, Hiroyuki; Amaki, Makoto; Hasegawa, Takuya; Sugano, Yasuo; Kanzaki, Hideaki; Anzai, Toshihisa

    2016-03-01

    A 66-year-old female, under regular follow-up for 20 years after aortic valve replacement (19-mm Carbomedics), presented dyspnea on effort and hypotension during hemodialysis. A transthoracic echocardiogram showed elevation of transvalvular velocity up to 4 m/s, but the structure around the aortic prosthesis was difficult to observe due to artifacts. Fluoroscopy revealed normal motion of the leaflets of the mechanical valve. Intracardiac echocardiography (ICE) revealed a pannus-like structure in the left ventricular outflow tract. Transesophageal echocardiogram also revealed this structure. ICE can visualize structural abnormalities around a prosthetic valve after cardiac surgery even in patients in whom conventional imaging modalities failed.

  13. Ultrasound of neck lymph nodes: How to do it and how do they look?

    Energy Technology Data Exchange (ETDEWEB)

    Ying, Michael [Department of Optometry and Radiography, Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China); Ahuja, Anil T. [Department of Diagnostic Radiology and Organ Imaging, Chinese University of Hong Kong, Prince of Wales Hospital, Shatin New Territories, Hong Kong (China)]. E-mail: aniltahuja@cuhk.edu.hk

    2006-05-15

    Cervical lymphadenopathy is commonly caused by metastases, lymphoma, tuberculosis and reactive hyperplasia. Before making an accurate diagnosis of pathologic lymph nodes, a clear understanding of the normal appearances of cervical nodes is crucial. Ultrasound examination of cervical lymph nodes is common in routine clinical practice because of its high sensitivity and specificity when combined with ultrasound-guided fine-needle aspiration cytology (FNAC). This article reviews the ultrasound of cervical lymph nodes including classification of the nodes, equipment, scanning technique and sonographic appearances of normal and common abnormal lymph nodes. The sonographic appearance of unusual cervical lymphadenopathy and the value of three-dimensional ultrasound in the volumetric measurements of cervical nodes are also discussed.

  14. Ultrasound of neck lymph nodes: How to do it and how do they look?

    International Nuclear Information System (INIS)

    Ying, Michael; Ahuja, Anil T.

    2006-01-01

    Cervical lymphadenopathy is commonly caused by metastases, lymphoma, tuberculosis and reactive hyperplasia. Before making an accurate diagnosis of pathologic lymph nodes, a clear understanding of the normal appearances of cervical nodes is crucial. Ultrasound examination of cervical lymph nodes is common in routine clinical practice because of its high sensitivity and specificity when combined with ultrasound-guided fine-needle aspiration cytology (FNAC). This article reviews the ultrasound of cervical lymph nodes including classification of the nodes, equipment, scanning technique and sonographic appearances of normal and common abnormal lymph nodes. The sonographic appearance of unusual cervical lymphadenopathy and the value of three-dimensional ultrasound in the volumetric measurements of cervical nodes are also discussed

  15. IVF: exploiting intensity variation function for high-performance pedestrian tracking in forward-looking infrared imagery

    Science.gov (United States)

    Lamberti, Fabrizio; Sanna, Andrea; Paravati, Gianluca; Belluccini, Luca

    2014-02-01

    Tracking pedestrian targets in forward-looking infrared video sequences is a crucial component of a growing number of applications. At the same time, it is particularly challenging, since image resolution and signal-to-noise ratio are generally very low, while the nonrigidity of the human body produces highly variable target shapes. Moreover, motion can be quite chaotic with frequent target-to-target and target-to-scene occlusions. Hence, the trend is to design ever more sophisticated techniques, able to ensure rather accurate tracking results at the cost of a generally higher complexity. However, many of such techniques might not be suitable for real-time tracking in limited-resource environments. This work presents a technique that extends an extremely computationally efficient tracking method based on target intensity variation and template matching originally designed for targets with a marked and stable hot spot by adapting it to deal with much more complex thermal signatures and by removing the native dependency on configuration choices. Experimental tests demonstrated that, by working on multiple hot spots, the designed technique is able to achieve the robustness of other common approaches by limiting drifts and preserving the low-computational footprint of the reference method.

  16. Ultrasound Imaging Methods for Breast Cancer Detection

    NARCIS (Netherlands)

    Ozmen, N.

    2014-01-01

    The main focus of this thesis is on modeling acoustic wavefield propagation and implementing imaging algorithms for breast cancer detection using ultrasound. As a starting point, we use an integral equation formulation, which can be used to solve both the forward and inverse problems. This thesis

  17. Causes of discordant or negative ultrasound of parathyroid glands in treatment naïve patients with primary hyperparathyroidism

    International Nuclear Information System (INIS)

    Chandramohan, Anuradha; Sathyakumar, Kirthi; Irodi, Aparna; Abraham, Deepak; Paul, M.J.

    2012-01-01

    Objectives: To describe causes of discordant or negative parathyroid ultrasound and to assess factors influencing them. Materials and methods: Retrospective review of patients who underwent parathyroidectomy between 2000 and 2012 was done. Imaging findings were compared with operative findings and pathology to identify discrepant (n = 60; 32 negative, 28 incorrect) parathyroid ultrasounds. Results: Fifty (83.3%) patients had parathyroid adenoma, of which 10 (16.6%) were ectopic and three were double adenomas; 8 (13.3%) had multigland hyperplasia and two had parathyroid carcinoma. Discrepant reports were due to incorrect localisation in 8 (13.3%); difficulty in differentiating thyroid from parathyroid lesion in 12 (20%); large and small size in two and three patients, respectively; overcall in 5 (8.3%) and satisfaction of search in 7 (11.7%) patients. There was significant correlation between presence of multi-nodular goitre and incorrect reports (χ 2 = 4.112, p = 0.04). Experience of ultrasound operators performing initial and second look ultrasound was significantly different (p < 0.0001). Second look ultrasound was concordant with surgical findings in 39(65%) patients; 21 (66%) patients with initially negative ultrasound and four out of five extra-mediastinal ectopic lesions. Ten patients with negative initial ultrasound had elongated parathyroid lesion. Scintigraphy was concordant in 44 (73.3%) patients and nine were ectopic. Conclusion: Second look ultrasound performed by experienced operator for negative or discordant initial ultrasound of parathyroid is a useful strategy which will improve the accuracy of parathyroid ultrasound. Being able to differentiate thyroid from parathyroid lesion is a factor which will influence performance of parathyroid ultrasound.

  18. Causes of discordant or negative ultrasound of parathyroid glands in treatment naïve patients with primary hyperparathyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Chandramohan, Anuradha, E-mail: anuradhachandramohan@gmail.com [Department of Radiology, Christian Medical College, Vellore, Tamil Nadu 632004 (India); Sathyakumar, Kirthi, E-mail: kirthi86s@yahoo.com [Department of Radiology, Christian Medical College, Vellore, Tamil Nadu 632004 (India); Irodi, Aparna, E-mail: aparnashyam@gmail.com [Department of Radiology, Christian Medical College, Vellore, Tamil Nadu 632004 (India); Abraham, Deepak, E-mail: abrahamdt@gmail.com [Department of Endocrine Surgery, Christian Medical College, Vellore, Tamil Nadu 632004 (India); Paul, M.J., E-mail: mjpaul@cmcvellore.ac.in [Department of Endocrine Surgery, Christian Medical College, Vellore, Tamil Nadu 632004 (India)

    2012-12-15

    Objectives: To describe causes of discordant or negative parathyroid ultrasound and to assess factors influencing them. Materials and methods: Retrospective review of patients who underwent parathyroidectomy between 2000 and 2012 was done. Imaging findings were compared with operative findings and pathology to identify discrepant (n = 60; 32 negative, 28 incorrect) parathyroid ultrasounds. Results: Fifty (83.3%) patients had parathyroid adenoma, of which 10 (16.6%) were ectopic and three were double adenomas; 8 (13.3%) had multigland hyperplasia and two had parathyroid carcinoma. Discrepant reports were due to incorrect localisation in 8 (13.3%); difficulty in differentiating thyroid from parathyroid lesion in 12 (20%); large and small size in two and three patients, respectively; overcall in 5 (8.3%) and satisfaction of search in 7 (11.7%) patients. There was significant correlation between presence of multi-nodular goitre and incorrect reports (χ{sup 2} = 4.112, p = 0.04). Experience of ultrasound operators performing initial and second look ultrasound was significantly different (p < 0.0001). Second look ultrasound was concordant with surgical findings in 39(65%) patients; 21 (66%) patients with initially negative ultrasound and four out of five extra-mediastinal ectopic lesions. Ten patients with negative initial ultrasound had elongated parathyroid lesion. Scintigraphy was concordant in 44 (73.3%) patients and nine were ectopic. Conclusion: Second look ultrasound performed by experienced operator for negative or discordant initial ultrasound of parathyroid is a useful strategy which will improve the accuracy of parathyroid ultrasound. Being able to differentiate thyroid from parathyroid lesion is a factor which will influence performance of parathyroid ultrasound.

  19. Ultrasound update: Where we've been, where we're heading

    International Nuclear Information System (INIS)

    Rodriguez, J.

    1987-01-01

    The roots of diagnostic ultrasound are less than 30 years old, yet the technological advances have far surpassed the expectations of its founding fathers. The boom age of ultrasound, the 1970s, was characterized by new equipment, procedures, and educational opportunities. The growth of ultrasound has temporarily leveled out, but a new age of technological advances is again visible on the horizon. This lecture looks back to the impact of the 1970s and the new boom of the 1980s

  20. CDM: Taking stock and looking forward

    International Nuclear Information System (INIS)

    Ellis, Jane; Winkler, Harald; Corfee-Morlot, Jan; Gagnon-Lebrun, Frederic

    2007-01-01

    The Kyoto Protocol's clean development mechanism (CDM) was established in 1997 with the dual purposes of assisting non-Annex I Parties in achieving sustainable development and assisting Annex I Parties in achieving compliance with their quantified greenhouse gas (GHG) emission commitments. This paper looks at the development of the CDM portfolio as well as achievements of the CDM to date in the context of wider private and public flows of investment into developing countries. These achievements include the development of 325 (by May 2005) proposed CDM projects which are together expected to generate more than 79 Mt CO 2 -eq credits/year during 2008-2012, increasing awareness of climate change mitigation options among possible investors and others that may facilitate transactions (i.e. governments), and the strengthening of climate-relevant institutions within countries. The paper also draws lessons from this experience to date, and outlines what changes may be needed to transform the CDM concept to a broader scale after the end of the first commitment period in 2012

  1. Intracardiac Echocardiography Evaluation in Secundum Atrial Septal Defect Transcatheter Closure

    International Nuclear Information System (INIS)

    Zanchetta, Mario; Pedon, Luigi; Rigatelli, Gianluca; Carrozza, Antonio; Zennaro, Marco; Di Martino, Roberta; Onorato, Eustaquio; Maiolino, Pietro

    2003-01-01

    Purpose: This study was designed to assess the balloon sizing maneuvers and deployment of an Amplatzer Septal Occluder (ASO). In addition, intraprocedural balloon sizing was compared with off-line intracardiac echocardiographic measurements. Methods: The intracardiac echocardiography (ICE) measurements were: maximum transverse and longitudinal atrial septal defect (ASD) diameters in the aortic valve and four-chamber planes;area of the ASD and its equivalent circle diameter. Thirteen consecutive patients underwent transcatheter implantation of an ASO device using ICE guidance under local anesthesia. The device matching the balloon sizing diameter of the defect was implanted. Qualitative ICE assessment of the ASO devices implanted was performed off line. Results: The mean equivalent circle diameter predicted by ICE was 24.40 ± 5.61 mm and was significantly higher(p 0.027) than the ASD measured by balloonsizing (21.38 ± 5.28 mm). Unlike previous studies we did not find any correlation between the two measurements (correlation coefficient = 0.47). Only four of the 13 patients had optimal device positioning as shown by the qualitative ICE evaluation, whereas the remaining nine patients had inadequate device placement. This resulted in a waist diameter that was an average 26.1% undersized in seven patients and 12.7% oversized in two patients. Five of the seven patients with an undersized device had ASO-atrial septum misalignment with leftward device deviation. Conclusion: The ICE images allowed careful measurement of the dimensions of the ASD and accurately displayed the spatial relations of the ASO astride the ASD.Moreover, use of the ICE measurement led to selection of a different size of device in comparison with those of balloon sizing. The clinical benefit of this new approach needs to be rigorously tested

  2. Medizinbibliotheken 20XX. Zuverlässig, Zukunftsweisend, Unverzichtbar [Medical Libraries 20XX. Reliable, forward-looking, indispensible

    Directory of Open Access Journals (Sweden)

    Bauer, Bruno

    2012-12-01

    Full Text Available [english] The focus of the current issue 3/2012 of GMS Medizin – Bibliothek – Information is the annual conference 2012 of the German Medical Libraries Association in Aachen. The motto of the conference was “Medical Libraries 20XX. Reliable, forward-looking, indispensible”. Focal points of the meeting were innovation management, marketing and new applications and services in medical libraries.The authors in this issue are Bruno Bauer (Open Access Publishing in Austria 2012, Thomas M. Deserno (Literature for interdisciplinary scientists – a requirement engineering approach, Annette Kustos (The new Academic Health Sciences, Nursing and Therapeutics Library of the University of Applied Health Sciences, Bochum, Christoph Poley (On the way to semantic web – with MEDPILOT, Henriette Senst & Jens Erling (New areas of work in the library of the Robert Koch-Institute: Open Access and institutional repository, Matti Stöhr (“I was interested in competitive alternatives to Citavi”: About the workshop “Reference Management at the focal point”, held at the AGMB-Conference 2012, Martin Zangl (Quality management in art libraries – a starting point for patient libraries?! and Ulf Paepcke & Gabriele Menzel (Medical Libraries 20XX. – Reliable, forward-looking, indispensible. Annual Meeting 2012 of the German MLA (AGMB September 24th to 26th in Aachen.[german] Schwerpunktthema der aktuellen Ausgabe 3/2012 von GMS Medizin – Bibliothek – Information ist die Jahrestagung 2012 der Arbeitsgemeinschaft für Medizinisches Bibliothekswesen (AGMB in Aachen; das Motto lautete „Medizinbibliotheken 20XX. Zuverlässig, Zukunftsweisend, Unverzichtbar“. Zentrales Thema der diesjährigen Tagung waren Open Access Publishing, Innovationsmanagement und neue Arbeitsfelder für Medizinbibliotheken.Die Beiträge der Schwerpunktausgabe wurden verfasst von Bruno Bauer (Open Access Publishing in Österreich 2012, Thomas M. Deserno (Literatur f

  3. Aortic intracardiac echocardiography-guided septal puncture during mitral valvuloplasty.

    Science.gov (United States)

    Akkaya, Emre; Vuruskan, Ertan; Zorlu, Ali; Sincer, Isa; Kucukosmanoglu, Mehmet; Ardic, Idris; Yilmaz, Mehmet Birhan

    2014-01-01

    Transoesophageal echocardiography (TEE) and venous intracardiac echocardiography (ICE) are traditionally used to visualize the interatrial septum (IAS) and the tenting effect of the fossa ovalis in patients undergoing percutaneous balloon mitral valvuloplasty (PBMV). The aim of the present study was to assess the comparative efficacy and safety of arterial (intra-aortic) ICE and venous ICE, compared with TEE (traditional approach), in the patients undergoing PBMV. TEE, aortic ICE, and venous ICE were consecutively performed in 50 patients (40 ± 9 years, 86% female). The images of intracardiac structures were obtained from both aortic and right atrial loci. The IAS was visualized using TEE, aortic ICE, and venous ICE. The mean mitral valve area was 1.14 ± 0.2 cm(2), and the mean left atrial volume index was 57.5 ± 12 mL/m(2). The mean size of the visualized septal length was 48 ± 5 mm by TEE, 51 ± 5 mm by aortic ICE, and 33 ± 6 mm by venous ICE. The Bland-Altman test indicated that the 95% limits of agreement for the measurement of septal diameter ranged from -11.0 to +5.9 mm (mean -2.5 mm) between TEE and aortic ICE, -2.8 to +33.5 mm (mean +15.3 mm) between TEE and venous ICE, and -36.6 to +0.8 mm (mean -17.9 mm) between venous and aortic ICE. Standard venous ICE generally tended to yield smaller values compared with TEE and aortic ICE for the measurement of septal length. Furthermore, the view of fossa ovalis and 'tenting effect' was optimal in 11 patients on venous ICE; however, the fossa ovalis and tip of the needle were well visualized in all patients on aortic ICE (P < 0.001). There were no major complications with the use of aortic ICE. Aortic ICE is a superior alternative to venous ICE and facilitates trans-septal puncture in patients with mitral stenosis.

  4. Navigate the net: looking back and moving forward.

    Science.gov (United States)

    Berryman, Donna; Hoy, Matt

    2009-10-01

    The Navigate the Net column will be under new joint editorship beginning with volume 29, issue number 1, 2010. In this column, the new editors look back at the past 15 years and discuss the purpose of the column and changes that have taken place in the way medical librarians use and relate to the Internet. The contributions of the previous editors are recognized and the purpose and future direction of the column are discussed. Brief biographies of the new editors are also included.

  5. Job demands-resources theory: Taking stock and looking forward.

    Science.gov (United States)

    Bakker, Arnold B; Demerouti, Evangelia

    2017-07-01

    The job demands-resources (JD-R) model was introduced in the international literature 15 years ago (Demerouti, Bakker, Nachreiner, & Schaufeli, 2001). The model has been applied in thousands of organizations and has inspired hundreds of empirical articles, including 1 of the most downloaded articles of the Journal of Occupational Health Psychology (Bakker, Demerouti, & Euwema, 2005). This article provides evidence for the buffering role of various job resources on the impact of various job demands on burnout. In the present article, we look back on the first 10 years of the JD-R model (2001-2010), and discuss how the model matured into JD-R theory (2011-2016). Moreover, we look at the future of the theory and outline which new issues in JD-R theory are worthwhile of investigation. We also discuss practical applications. It is our hope that JD-R theory will continue to inspire researchers and practitioners who want to promote employee well-being and effective organizational functioning. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  6. Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation.

    Science.gov (United States)

    Rivas-Lalaleo, David; Muñoz-Romero, Sergio; Huerta, Mónica; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2018-05-02

    The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These

  7. Diagnostic dilemma: Intracardiac mass in a woman with Behçet's syndrome.

    Science.gov (United States)

    Núñez-Cabarcas, Edilberto; López-Ruiz, Nilson; Ramírez-Rincón, Alex

    2014-01-01

    Intracardiac thrombosis is a rare manifestation of cardiac involvement in Behçet's disease, and it may be mistaken for a heart tumor. In this letter we present the case of a patient diagnosed with Behçet's disease who was incidentally found to have a mass in the right atrium suspicious of a cardiac tumor. Nevertheless, cardiac magnetic resonance showed a cardiac thrombus. Immunosuppressive therapy and anticoagulation were effective for thrombus resolution. Copyright © 2014 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  8. Brookhaven at 40 - looking forward as well as back

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    In 1947, the famous Camp Upton Army Base on New York's Long Island switched to a new career as Brookhaven National Laboratory. The reputation the Laboratory has established as a world-class research centre and its continued attraction for scientists looking for exciting possibilities were highlighted on 9-11 September at a symposium and celebration marking forty years of Brookhaven and its parent organization, AUI (Associated Universities Inc)

  9. Cardiac Limited Ultrasound Examination Techniques to Augment the Bedside Cardiac Physical Examination.

    Science.gov (United States)

    Kimura, Bruce J; Shaw, David J; Amundson, Stan A; Phan, James N; Blanchard, Daniel G; DeMaria, Anthony N

    2015-09-01

    The current practice of physical diagnosis is dependent on physician skills and biases, inductive reasoning, and time efficiency. Although the clinical utility of echocardiography is well known, few data exist on how to integrate 2-dimensional screening "quick-look" ultrasound applications into a novel, modernized cardiac physical examination. We discuss the evidence basis behind ultrasound "signs" pertinent to the cardiovascular system and elemental in synthesis of bedside diagnoses and propose the application of a brief cardiac limited ultrasound examination based on these signs. An ultrasound-augmented cardiac physical examination can be taught in traditional medical education and has the potential to improve bedside diagnosis and patient care. © 2015 by the American Institute of Ultrasound in Medicine.

  10. 4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography.

    Science.gov (United States)

    Wildes, Douglas; Lee, Warren; Haider, Bruno; Cogan, Scott; Sundaresan, Krishnakumar; Mills, David M; Yetter, Christopher; Hart, Patrick H; Haun, Christopher R; Concepcion, Mikael; Kirkhorn, Johan; Bitoun, Marc

    2016-12-01

    We developed a 2.5 ×6.6 mm 2 2 -D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm 2 area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 ° ×60 ° ×8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.

  11. Programmes of Educational Technology in China: Looking Backward, Thinking Forward

    Science.gov (United States)

    Fuyin, Xu; Jianli, Jiao

    2010-01-01

    There is a history of programmes in educational technology in colleges and universities in China going back about 70 years. This paper briefly reviews the developmental history of the educational technology programme in China, elaborates the status-quo of the programme and looks ahead into the future trends of educational technology development in…

  12. Looking Forward to the electronic Geophysical Year

    Science.gov (United States)

    Kamide, Y.; Baker, D. N.; Thompson, B.; Barton, C.; Kihn, E.

    2004-12-01

    During the International Geophysical Year (1957-1958), member countries established many new capabilities pursuing the major IGY objectives of collecting geophysical data as widely as possible and providing free access to these data for all scientists around the globe. A key achievement of the IGY was the establishment of a worldwide system of data centers and physical observatories. The worldwide scientific community has now endorsed and is promoting an electronic Geophysical Year (eGY) initiative. The proposed eGY concept would both commemorate the 50th anniversary of the IGY in 2007-2008 and would provide a forward impetus to geophysics in the 21st century, similar to that provide by the IGY fifty years ago. The eGY concept advocates the establishment of a series of virtual geophysical observatories now being deployed in cyberspace. We discuss plans to aggregate measurements into a readily accessible database along with analysis, visualization, and display tools that will make information available and useful to the scientific community, to the user community, and to the general public. We are examining the possibilities for near-realtime acquisition of data and utilization of forecast tools in order to provide users with advanced space weather capabilities. This program will provide powerful tools for education and public outreach concerning the connected Sun-Earth System.

  13. Ext JS 4 First Look

    CERN Document Server

    Groner, Loiane

    2012-01-01

    This book is a practical step-by-step tutorial which guides you to migrate from Ext JS 3 to Ext JS 4. There are examples backed with explanations and plenty of code and illustrations to look forward to. This book is written for web developers who are familiar with Ext JS 3 and want to have detailed insights into the new features of Ext JS 4.

  14. Physicians using ultrasound in Danish emergency departments are mostly summoned specialists

    DEFF Research Database (Denmark)

    Nielsen, Klaus; Lauridsen, Johnny Rene Meilstrup; Laursen, Christian Borbjerg

    2015-01-01

    ultrasound and 304 were non-users (54 %, 95 % CI: 50-58). The largest group with 146 respondents (25 %, 95 % CI: 21-29) were anaesthetists with merely consult duty in the ED. When looking exclusively on physicians with on-call duty in the ED, thus excluding anaesthetists, only 146 (35 %, 95 % CI: 30-40) were...... young physicians with on call duty in the ED. CONCLUSIONS: We have found that although almost all Danish EDs have ultrasound equipment available, few physicians working in the ED seem to have adopted the tool. Emergency Ultrasound is mainly performed by specialists who are summoned to the ED in case...

  15. Benefits of Sharing Information from Commercial Airborne Forward-Looking Sensors in the Next Generation Air Transportation System

    Science.gov (United States)

    Schaffner, Philip R.; Harrah, Steven; Neece, Robert T.

    2012-01-01

    The air transportation system of the future will need to support much greater traffic densities than are currently possible, while preserving or improving upon current levels of safety. Concepts are under development to support a Next Generation Air Transportation System (NextGen) that by some estimates will need to support up to three times current capacity by the year 2025. Weather and other atmospheric phenomena, such as wake vortices and volcanic ash, constitute major constraints on airspace system capacity and can present hazards to aircraft if encountered. To support safe operations in the NextGen environment advanced systems for collection and dissemination of aviation weather and environmental information will be required. The envisioned NextGen Network Enabled Weather (NNEW) infrastructure will be a critical component of the aviation weather support services, providing access to a common weather picture for all system users. By taking advantage of Network Enabled Operations (NEO) capabilities, a virtual 4-D Weather Data Cube with aviation weather information from many sources will be developed. One new source of weather observations may be airborne forward-looking sensors, such as the X-band weather radar. Future sensor systems that are the subject of current research include advanced multi-frequency and polarimetric radar, a variety of Lidar technologies, and infrared imaging spectrometers.

  16. 'Looking Back is Looking Forward': Towards a Theory of Tradition in Niyi Osundare's Poetry

    Directory of Open Access Journals (Sweden)

    Christopher Anyokwu

    2013-11-01

    Full Text Available As T.S. Eliot informs us, no one ever has his meaning alone, since the artist does not create ex nihilo. Thus, every artist looks to the past-or Tradition - for inspiration and, indeed, for the very material of creativity. This Eliotesque theory of tradition, it is observed, seems to fundamentally inform and shape Niyi Osundare's poetry insofar as he relies mainly on Yoruba orature and the poetries of the English-speaking world. In this study, therefore, we examine the place of tradition in Osundare's verse with a view to generating a theory of tradition in his work in particular and modern Nigerian poetry of English expression in general.

  17. Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis

    Directory of Open Access Journals (Sweden)

    G. Carrault

    2008-09-01

    Full Text Available Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA. The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.

  18. Using Intracardiac Vectorcardiographic Loop for Surface ECG Synthesis

    Science.gov (United States)

    Kachenoura, A.; Porée, F.; Hernández, A. I.; Carrault, G.

    2008-12-01

    Current cardiac implantable devices offer improved processing power and recording capabilities. Some of these devices already provide basic telemonitoring features that may help to reduce health care expenditure. A challenge is posed in particular for the telemonitoring of the patient's cardiac electrical activity. Indeed, only intracardiac electrograms (EGMs) are acquired by the implanted device and these signals are difficult to analyze directly by clinicians. In this paper, we propose a patient-specific method to synthesize the surface electrocardiogram (ECG) from a set of EGM signals, based on a 3D representation of the cardiac electrical activity and principal component analysis (PCA). The results, in the case of sinus rhythm, show a correlation coefficient between the real ECG and the synthesized ECG of about 0.85. Moreover, the application of the proposed method to the patients who present an abnormal heart rhythm exhibits promising results, especially for characterizing the bundle branch blocs. Finally, in order to evaluate the behavior of our procedure in some practical situations, the quality of the ECG reconstruction is studied as a function of the number of EGM electrodes provided by the CIDs.

  19. Arterial wave intensity and ventricular-arterial coupling by vascular ultrasound: rationale and methods for the automated analysis of forwards and backwards running waves.

    Science.gov (United States)

    Rakebrandt, F; Palombo, C; Swampillai, J; Schön, F; Donald, A; Kozàkovà, M; Kato, K; Fraser, A G

    2009-02-01

    Wave intensity (WI) in the circulation is estimated noninvasively as the product of instantaneous changes in pressure and velocity. We recorded diameter as a surrogate for pressure, and velocity in the right common carotid artery using an Aloka SSD-5500 ultrasound scanner. We developed automated software, applying the water hammer equation to obtain local wave speed from the slope of a pressure/velocity loop during early systole to separate net WI into individual forwards and backwards-running waves. A quality index was developed to test for noisy data. The timing, duration, peak amplitude and net energy of separated WI components were measured in healthy subjects with a wide age range. Age and arterial stiffness were independent predictors of local wave speed, whereas backwards-travelling waves correlated more strongly with ventricular systolic function than with age-related changes in arterial stiffness. Separated WI offers detailed insight into ventricular-arterial interactions that may be useful for assessing the relative contributions of ventricular and vascular function to wave travel.

  20. Arbitrage free pricing of forward and futures in the energy market

    International Nuclear Information System (INIS)

    Kloster, Kristian

    2003-01-01

    contract is settled. To demonstrate the performance of my model, I will find different forward curves with different delivery times and compare them with actual forward curves from Akershus energy. Then I deduce an option price with a forward/futures as an underlying asset. The option price, will be a generalized version of the Black 76 model. Black 76 is the most applicable and used option pricing model in the Nordic energy market. The thesis is organized as follows: Chapter 1 has been a general introduction to the electricity market, and the topics I will look at in this thesis. In chapter 2 I will look at some properties of the energy prices. In chapter 3 and 4, I introduce the model for the spot price dynamics, and look at some properties for the model. I also discuss equivalent Martingale measure in view of this. I derive the forward/futures prices and I look at some fitting techniques to estimate my variables in chapter 5 and 6. In chapter 7 I will present the performance of the model. I deduce an option price in chapter 8. Chapter 9 will be a discussion of my findings. Some basic theorems and solution algorithms are left to an appendix. The main objectives of this thesis were to derive a formula for arbitrage free pricing of forward and futures contracts in the energy market, and also derive an option price using the forward as an underlying asset. The first chapters provided me with the material I needed to derive these formulas. In chapter 7 I tested my theoretical model against forward curves in the market. There are several possible explanations for the results from chapter 7. One possibility is that. the stochastic spot model is poor for electricity prices, and perhaps works better for other energy markets. My Ornstein-Uhlenbeck process is only driven by Wiener noise and no Levy noise. An inclusion of a Levy term could increase the prediction in case of sudden shifts in the spot price. The Nordic electricity market is a new market, which is very sensitive to

  1. Rule-Blocking and Forward-Looking Conditions in the Computational Modelling of Pāṇinian Derivation

    Science.gov (United States)

    Scharf, Peter M.

    Attempting to model Pāṇinian procedure computationally forces one to clarify concepts explicitly and allows one to test various versions and interpretations of his grammar against each other and against bodies of extant Sanskrit texts. To model Pāṇinian procedure requires creating data structures and a framework that allow one to approximate the statement of Pāṇinian rules in an executable language. Scharf (2009: 117-125) provided a few examples of how rules would be formulated in a computational model of Pāṇinian grammar as opposed to in software that generated speech forms without regard to Pāṇinian procedure. Mishra (2009) described the extensive use of attributes to track classification, marking and other features of phonetic strings. Goyal, Kulkarni, and Behera (2009, especially sec. 3.5) implemented a model of the asiddhavat section of rules (6.4.22-129) in which the state of the data passed to rules of the section is maintained unchanged and is utilized by those rules as conditions, yet the rules of the section are applied in parallel, and the result of all applicable rules applying exits the section. The current paper describes Scharf and Hyman's implementation of rule blocking and forward-looking conditions. The former deals with complex groups of rules concerned with domains included within the scope of a general rule. The latter concerns a case where a decision at an early stage in the derivation requires evaluation of conditions that do not obtain until a subsequent stage in the derivation.

  2. Interaction of ultrasound with vortices in type-II superconductors

    International Nuclear Information System (INIS)

    Sonin, E.B.

    1996-01-01

    The theory of ultrasound in the mixed state of type-II superconductors is suggested which takes into account the Magnus force on vortices, the anti-Magnus force on ions, and diamagnetism of the mixed state. The acoustic Faraday effect (rotation of polarization of the transverse ultrasonic wave propagating along vortices) is linear in the Magnus force in any regime of the flux flow for wavelengths now used in the ultrasound experiments. Therefore, in contrast to previous predictions, the Faraday effect should be looked for only in clean superconductors with a strong Magnus force. copyright 1996 The American Physical Society

  3. Detection of intracardiac thrombi by 111In-oxine platelet imaging

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Hayashi, Makoto; Hayashida, Kohei; Uehara, Toshiisa; Naito, Hiroaki; Kozuka, Takahiro; Boku, Eidai; Sakakibara, Hiroshi

    1985-01-01

    111 In-oxine platelet imaging (RI) was undertaken in 55 patients with suspected intracardiac thrombi. The results were compared with those from echocardiography (US) and computed tomography (CT). Sensitivity and specificity of RI were 71 % and 92 %, respectively. Visualizing thrombi on RI was seen in 10 (56 %) of 18 patients receiving anticoagulant therapy such as Warfarin (Group A) and in 12 (92 %) of 13 patients without it (Group B). This implied that active platelet deposition is inhibited by giving Warfarin. Regarding the size of thrombi, three methods showed the same size in 11 (85 %) of Group B. RI showed smaller thrombi than US and CT in 7 (39 %) of Group A, and failed to reveal them in 8 (44 %). Unlike morphological diagnosis by US and CT, RI proved to be of value in the evaluation of the activity of platelets (platelet deposition on the surface of thrombus). This method can also be used in the evaluation of thrombogenity. (Namekawa, K.)

  4. Looking Back, Looking Forward

    DEFF Research Database (Denmark)

    Zierau, Eld; Laursen, Ditte

    anticipated, as a study last year indicated that different methods found different web material. The study used one approach based on Internet Archives data and one approach based on out-links from a national web archive (Zierau 2015). The conclusion is that more methods should be used to find data and embed...... have moved to generic Top Level Domains like .com or .org (Mjøs 2012). This challenge has grown as the use of foreign web hotels, blogs and social media like twitter and Facebook has exploded, and where hosts are geographically located outside the country’s boarders. The challenge is far bigger than...... them in a web archive. This presentation will include a description of an operational setup to meet this challenge (to be implemented in 2016). The setup is designed to deal with different (present and future) sources. The sources can be any URL set to be investigated. It can also be derived data (e...

  5. Look back, look forward

    International Nuclear Information System (INIS)

    Simonsen, H.

    1985-01-01

    The article is a brief description of the roles of Mintek and the former Atomic Energy Board in research into the extraction of South African uranium. The present static world demand for uranium requires more process economies in the short term while in the longer term the growing number of nuclear power plants will place increasing demands on uranium producers. The different extraction processes developed as a result of research are discussed. Particular attention is being paid to the development of low-cost processes of which the resin-in-pulp (RIP) process is perhaps the most important. This process however, still requires attention in various areas

  6. Single-chip CMUT-on-CMOS front-end system for real-time volumetric IVUS and ICE imaging.

    Science.gov (United States)

    Gurun, Gokce; Tekes, Coskun; Zahorian, Jaime; Xu, Toby; Satir, Sarp; Karaman, Mustafa; Hasler, Jennifer; Degertekin, F Levent

    2014-02-01

    Intravascular ultrasound (IVUS) and intracardiac echography (ICE) catheters with real-time volumetric ultrasound imaging capability can provide unique benefits to many interventional procedures used in the diagnosis and treatment of coronary and structural heart diseases. Integration of capacitive micromachined ultrasonic transducer (CMUT) arrays with front-end electronics in single-chip configuration allows for implementation of such catheter probes with reduced interconnect complexity, miniaturization, and high mechanical flexibility. We implemented a single-chip forward-looking (FL) ultrasound imaging system by fabricating a 1.4-mm-diameter dual-ring CMUT array using CMUT-on-CMOS technology on a front-end IC implemented in 0.35-μm CMOS process. The dual-ring array has 56 transmit elements and 48 receive elements on two separate concentric annular rings. The IC incorporates a 25-V pulser for each transmitter and a low-noise capacitive transimpedance amplifier (TIA) for each receiver, along with digital control and smart power management. The final shape of the silicon chip is a 1.5-mm-diameter donut with a 430-μm center hole for a guide wire. The overall front-end system requires only 13 external connections and provides 4 parallel RF outputs while consuming an average power of 20 mW. We measured RF A-scans from the integrated single- chip array which show full functionality at 20.1 MHz with 43% fractional bandwidth. We also tested and demonstrated the image quality of the system on a wire phantom and an ex vivo chicken heart sample. The measured axial and lateral point resolutions are 92 μm and 251 μm, respectively. We successfully acquired volumetric imaging data from the ex vivo chicken heart at 60 frames per second without any signal averaging. These demonstrative results indicate that single-chip CMUT-on-CMOS systems have the potential to produce realtime volumetric images with image quality and speed suitable for catheter-based clinical applications.

  7. Diet and asthma: looking back, moving forward

    Directory of Open Access Journals (Sweden)

    Ellwood Philippa E

    2009-06-01

    this multidisciplinary approach is required to move forward and understand the complexity of the interaction of dietary factors and asthma.

  8. Nuclear Exciton Echo Produced by Ultrasound in Forward Scattering of Synchrotron Radiation

    International Nuclear Information System (INIS)

    Smirnov, G.V.; van Buerck, U.; Arthur, J.; Popov, S.L.; Baron, A.Q.; Chumakov, A.I.; Ruby, S.L.; Potzel, W.; Brown, G.S.

    1996-01-01

    The time evolution of the coherent decay of a collective nuclear excitation (nuclear exciton), induced by 14.4 keV synchrotron radiation, was studied in a system of two stainless steel foils, where one was vibrated by ultrasound (US). The US vibrations disrupted the coherent nuclear emission from the two targets. However, at times corresponding to multiples of the US period, spike increases in the decay were observed. The spikes are interpreted as echoes of the initial nuclear exciton. copyright 1996 The American Physical Society

  9. Functional pulmonary atresia in newborn with normal intracardiac anatomy: Successful treatment with inhaled nitric oxide and pulmonary vasodilators

    Directory of Open Access Journals (Sweden)

    Gürkan Altun

    2013-01-01

    Full Text Available Functional pulmonary atresia is characterized by a structurally normal pulmonary valve that does not open during right ventricular ejection. It is usually associated with Ebstein′s anomaly, Uhl′s anomaly, neonatal Marfan syndrome and tricuspid valve dysplasia. However, functional pulmonary atresia is rarely reported in newborn with anatomically normal heart. We report a newborn with functional pulmonary atresia who had normal intracardiac anatomy, who responded to treatment with nitric oxide and other vasodilator therapy successfully.

  10. Looking Forward

    Indian Academy of Sciences (India)

    Co-benefits within a sustainable development framework. Problem of linkage: Should we be willing to put our co-benefits measures on the negotiating table? Diplomacy vs. development: Broaden debate to link development questions with climate change.

  11. The Year in Review, And a Look Ahead, Too.

    Science.gov (United States)

    Novelli, Joan

    1995-01-01

    This article presents easy computer projects to send students into the summer feeling good about the past year and looking forward to the next. The projects involve printing summer reading book lists, making bridges to the next grade, publishing books of class events, designing reading posters, and creating summer calendars. (SM)

  12. Shunt detection and measurement

    International Nuclear Information System (INIS)

    Grossman, W.

    1986-01-01

    Detection, localization, and quantification of intracardiac shunts are an integral part of the hemodynamic evaluation of patients with congenital heart disease. In most cases, an intracardiac shunt is suspected on the basis of the clinical evaluation of the patient prior to catheterization. However, there are several circumstances in which data obtained at catheterization should alert the cardiologist to look for a shunt that previously had not been suspected

  13. Myopic and Forward Looking Behavior in Branded Oral Anti-Diabetic Medication Consumption: An Example from Medicare Part D.

    Science.gov (United States)

    Sacks, Naomi C; Burgess, James F; Cabral, Howard J; Pizer, Steven D

    2017-06-01

    We evaluate consumption responses to the non-linear Medicare Part D prescription drug benefit. We compare propensity-matched older patients with diabetes and Part D Standard or low-income-subsidy (LIS) coverage. We evaluate monthly adherence to branded oral anti-diabetics, with high end-of-year donut hole prices (>$200) for Standard patients and consistent, low (≤$6) prices for LIS. As an additional control, we examine adherence to generic anti-diabetics, with relatively low, consistent prices for Standard patients. If Standard patients are forward looking, they will reduce branded adherence in January, and LIS-Standard differences will be constant through the year. Contrary to this expectation, branded adherence is lower for Standard patients in January and diverges from LIS as the coverage year progresses. Standard-LIS generic adherence differences are minimal. Our findings suggest that seniors with chronic conditions respond myopically to the nonlinear Part D benefit, reducing consumption in response to high deductible, initial coverage and gap prices. Thus, when the gap is fully phased out in 2020, cost-related nonadherence will likely remain in the face of higher spot prices for more costly branded medications. These results contribute to studies of Part D plan choice and medication adherence that suggest that seniors may not make optimal healthcare decisions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Grappling with Globalization, Partnership, and Learning: A Look inside Oxfam America.

    Science.gov (United States)

    Offenheiser, Raymond; Holcombe, Susan; Hopkins, Nancy

    1999-01-01

    Oxfam America is an international development and relief organization that is grappling with building a learning organization, creating constructive labor-management relations, and trying to position itself as one of the most effective, forward-looking nongovernmental organizations of the next century. (JOW)

  15. Virtual Ultrasound Guidance for Inexperienced Operators

    Science.gov (United States)

    Caine, Timothy; Martin, David

    2012-01-01

    advice on technique. The program also instructs the operator regarding the types of images to store and how to overcome pitfalls in scanning. Images can be forwarded to the ground or other site when convenient. Following study completion, the video glasses, video source, and ultrasound system are powered down and stored. Virtually any equipment that can play back video can be used to play back the program. This includes a DVD player, personal computer, and some MP3 players.

  16. High resolution three-dimensional robotic synthetic tracked aperture ultrasound imaging: feasibility study

    Science.gov (United States)

    Zhang, Haichong K.; Fang, Ting Yun; Finocchi, Rodolfo; Boctor, Emad M.

    2017-03-01

    Three dimensional (3D) ultrasound imaging is becoming a standard mode for medical ultrasound diagnoses. Conventional 3D ultrasound imaging is mostly scanned either by using a two dimensional matrix array or by motorizing a one dimensional array in the elevation direction. However, the former system is not widely assessable due to its cost, and the latter one has limited resolution and field-of-view in the elevation axis. Here, we propose a 3D ultrasound imaging system based on the synthetic tracked aperture approach, in which a robotic arm is used to provide accurate tracking and motion. While the ultrasound probe is moved by a robotic arm, each probe position is tracked and can be used to reconstruct a wider field-of-view as there are no physical barriers that restrict the elevational scanning. At the same time, synthetic aperture beamforming provides a better resolution in the elevation axis. To synthesize the elevational information, the single focal point is regarded as the virtual element, and forward and backward delay-andsum are applied to the radio-frequency (RF) data collected through the volume. The concept is experimentally validated using a general ultrasound phantom, and the elevational resolution improvement of 2.54 and 2.13 times was measured at the target depths of 20 mm and 110 mm, respectively.

  17. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  18. Intracardiac echo-guided radiofrequency catheter ablation of atrial fibrillation in patients with atrial septal defect or patent foramen ovale repair: a feasibility, safety, and efficacy study.

    Science.gov (United States)

    Lakkireddy, Dhanunjaya; Rangisetty, Umamahesh; Prasad, Subramanya; Verma, Atul; Biria, Mazda; Berenbom, Loren; Pimentel, Rhea; Emert, Martin; Rosamond, Thomas; Fahmy, Tamer; Patel, Dimpi; Di Biase, Luigi; Schweikert, Robert; Burkhardt, David; Natale, Andrea

    2008-11-01

    Intracardiac Echo-Guided Radiofrequency Catheter. Patients with atrial septal defect (ASD) are at higher risk for atrial fibrillation (AF) even after repair. Transseptal access in these patients is perceived to be difficult. We describe the feasibility, safety, and efficacy of pulmonary vein antral isolation (PVAI) in these patients. We prospectively compared post-ASD/patent foramen ovale (PFO) repair patients (group I, n = 45) with age-gender-AF type matched controls (group II, n = 45). All the patients underwent PVAI through a double transseptal puncture with a roving circular mapping catheter technique guided by intracardiac echocardiography (ICE). The short-term (3 months) and long-term (12 month) failure rates were assessed. In group I, 23 (51%) had percutaneous closure devices and 22 (49%) had a surgical closure. There was no significant difference between group I and II in the baseline characteristics. Intracardiac echo-guided double transseptal access was obtained in 98% of patients in group I and in 100% of patients in group II. PVAI was performed in all patients, with right atrial flutter ablation in 7 patients in group I and in 4 patients in group II. Over a mean follow-up of 15 +/- 4 months, group I had higher short-term (18% vs 13%, P = 0.77) and long-term recurrence (24% vs 18%, P = 0.6) than group II. There was no significant difference in the perioperative complications between the two groups. Echocardiography at 3 months showed interatrial communication in 2 patients in group I and 1 patient in group II, which resolved at 12 months. Percutaneous AF ablation using double transseptal access is feasible, safe, and efficacious in patients with ASD and PFO repairs.

  19. Mast Cell Coupling to the Kallikrein–Kinin System Fuels Intracardiac Parasitism and Worsens Heart Pathology in Experimental Chagas Disease

    Directory of Open Access Journals (Sweden)

    Clarissa R. Nascimento

    2017-08-01

    Full Text Available During the course of Chagas disease, infectious forms of Trypanosoma cruzi are occasionally liberated from parasitized heart cells. Studies performed with tissue culture trypomastigotes (TCTs, Dm28c strain demonstrated that these parasites evoke neutrophil/CXCR2-dependent microvascular leakage by activating innate sentinel cells via toll-like receptor 2 (TLR2. Upon plasma extravasation, proteolytically derived kinins and C5a stimulate immunoprotective Th1 responses via cross-talk between bradykinin B2 receptors (B2Rs and C5aR. Awareness that TCTs invade cardiovascular cells in vitro via interdependent activation of B2R and endothelin receptors [endothelin A receptor (ETAR/endothelin B receptor (ETBR] led us to hypothesize that T. cruzi might reciprocally benefit from the formation of infection-associated edema via activation of kallikrein–kinin system (KKS. Using intravital microscopy, here we first examined the functional interplay between mast cells (MCs and the KKS by topically exposing the hamster cheek pouch (HCP tissues to dextran sulfate (DXS, a potent “contact” activator of the KKS. Surprisingly, although DXS was inert for at least 30 min, a subtle MC-driven leakage resulted in factor XII (FXII-dependent activation of the KKS, which then amplified inflammation via generation of bradykinin (BK. Guided by this mechanistic insight, we next exposed TCTs to “leaky” HCP—forged by low dose histamine application—and found that the proinflammatory phenotype of TCTs was boosted by BK generated via the MC/KKS pathway. Measurements of footpad edema in MC-deficient mice linked TCT-evoked inflammation to MC degranulation (upstream and FXII-mediated generation of BK (downstream. We then inoculated TCTs intracardiacally in mice and found a striking decrease of parasite DNA (quantitative polymerase chain reaction; 3 d.p.i. in the heart of MC-deficient mutant mice. Moreover, the intracardiac parasite load was significantly reduced in WT

  20. Intracardiac metastasis of squamous cell carcinoma of the penis

    Directory of Open Access Journals (Sweden)

    Sheila Aparecida Coelho Siqueira

    2013-12-01

    Full Text Available Penile cancer shows variable incidence in different countries with a higher prevalence in developing countries. Squamous cell carcinoma represents the most common histologic type. The seventh decade of life corresponds to the mean age at diagnosis, but it is not an unusual diagnosis among young adults. Most cases present as “in situ” neoplasia or loco regional disease; however, systemic disseminated disease occurs via lymphatic and/or hematogeneous routes. The lymph nodes, liver, and lungs are the most frequently involved sites whereas the heart constitutes an exceptional and atypical site for penile cancer metastases. We report a case of a 79-year-old patient who presented a metastatic squamous cell carcinoma of the penis with intracardiac dissemination. The patient had a past history of cardiomyopathy, which required an artificial cardiac pacemaker implantation. He had been treated 1 year before with a partial penectomy but was admitted for emasculation due to the cancer relapse. During the postoperative period, he experienced sudden respiratory distress and died. The autopsy findings showed metastatic disease into the cardiac right chambers, pulmonary tumoral thrombi, and pulmonary hilar involvement. The authors call attention to the possibility of the presence of pacing leads, cardiomyopathy and the altered low blood flow in the right chambers, as predisposing factors for the tumoral seeding in this case.

  1. Europe looks forward to COROT launch

    Science.gov (United States)

    2006-12-01

    While CNES is completing preparations for the launch from Baikonur/Kazakhstan, ESA and a large number of European scientists involved in the mission are eagerly awaiting this event and the first scientific results to come through. What is COROT? COROT stands for ‘Convection Rotation and planetary Transits’. The name describes the mission’s scientific goals. ‘Convection and rotation’ refer to the satellite’s capability to probe stellar interiors, studying the acoustic waves that ripple across the surface of stars, a technique called asteroseismology. ‘Transit’ refers to the technique whereby the presence of a planet orbiting a star can be inferred from the dimming starlight caused when the planet passes in front of it. To achieve its twin scientific objectives, COROT will monitor some 120,000 stars with its 30-centimetre telescope. COROT will lead a bold new search for planets around other stars. In the decade since the first discovery in 1995 of an exoplanet (51 Pegasi b), more than 200 other such planets outside our solar system have been detected using ground-based observatories. The COROT space telescope promises to find many more during its two-and-a-half-year mission, expanding the frontiers of our knowledge towards ever-smaller planets. Many of the planets COROT will detect are expected to be 'hot Jupiters', gaseous worlds. An unknown percentage of those detected are expected to be rocky planets, maybe just a few times larger than the Earth (or smaller, even). If COROT finds such planets, they will constitute a new class of planet altogether. While it is looking at a star, COROT will also be able to detect 'starquakes', acoustic waves generated deep inside a star that send ripples across its surface, altering its brightness. The exact nature of the ripples allows astronomers to calculate the star's precise mass, age and chemical composition. COROT’s European dimension The COROT mission was first proposed by CNES back in 1996. A call for

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  3. One-dimensional, forward-forward mean-field games with congestion

    KAUST Repository

    Gomes, Diogo A.; Sedjro, Marc

    2017-01-01

    forward-forward MFGs. Finally, we construct traveling-wave solutions, which settles in a negative way the convergence problem for forward-forward MFGs. A similar technique gives the existence of time-periodic solutions for non-monotonic MFGs.

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  5. Endocarditis associated with intracardiac devices

    International Nuclear Information System (INIS)

    Tourn, J.; Rocha, A.; Jubany, L.; Figueroa, S.; Sasso, D.; Dalto, L.; Ferreiro, A.; Fernandez, P.; Kuster, F.

    2013-01-01

    Full text: Background: Infective endocarditis (I E) associated with intracardiac devices (DIC) (pacemakers and CDAI) is a serious condition associated with high mortality (10-20%). Its incidence is variable according different studies but round 1.9 / 1000 devices year. The Eco and blood cultures are the pillars diagnosis of this disease. Early treatment reduces morbidity and mortality and is the extraction of entire system accompanied prolonged antibiotic therapy. Objective: To analyze the epidemiological, clinical, pathological and disease progression in patients EI carriers with DIC. Method: 3,110 DIC placed in the institution between April 2000 and February 2012 were identified by analysis of medical records EI 26 patients with DIC carriers. For diagnosis they were included EI definite cases according to the criteria Duke. They were classified into early EI (<12 months) or late (> 12 months) from the date of the last implant. Descriptive statistical analysis was performed. Result: The incidence was 8.3 / 1,000 DIC (n = 26). The mean age was 70 ± 10 years, 19 men, 9 diabetic and 16 patients had implemented a Ddd device. In 17 patients underwent more than one replacement device; 10 patients required temporary pacemaker (MPT) prior to placement permanent pacemaker. The average time since the last implant DIC at diagnosis was 710 days. The DIC extraction was early in 8 patients and late in 18. Topography of vegetation: 10 cases over the cable, six tricuspid valve, valve and four over six patient cable and vegetation not found. 15 patients blood cultures were positive; the most frequently found germ was staphylococcus aureus (S A) in nine, being this methicillin-resistant in five of them. The fever accompanied impact elements General was present in 24 cases. The most frequent medical complications were anemia in eight patients and acute renal failure in four patients. Two patients died during hospitalization (7.6%; 95% CI: 0-17.5%). The extraction system was

  6. Forward and Spot Prices in Multi-Settlement Wholesale Electricity Markets

    Science.gov (United States)

    Larrieu, Jeremy

    In organized wholesale electricity markets, power is sold competitively in a multi-unit multi-settlement single-price auction comprised of a forward and a spot market. This dissertation attempts to understand the structure of the forward premium in these markets, and to identify the factors that may lead forward and spot prices to converge or diverge. These markets are unique in that the forward demand is price-sensitive, while spot residual demand is perfectly inelastic and must be met in full, a crucial design feature the literature often glosses over. An important contribution of this dissertation is the explicit modeling of each market separately in order to understand how generation and load choose to act in each one, and the consequences of these actions on equilibrium prices and quantities given that firms maximize joint profits over both markets. In the first essay, I construct a two-settlement model of electricity prices in which firms that own asymmetric capacity-constrained units facing convex costs compete to meet demand from consumers, first in quantities, then in prices. I show that the forward premium depends on the costliness of spot production relative to firms' ability to exercise market power by setting quantities in the forward market. In the second essay, I test the model from the first essay with unit-level capacity and marginal cost data from the California Independent System Operator (CAISO). I show that the model closely replicates observed price formation in the CAISO. In the third essay, I estimate a time series model of the CAISO forward premium in order to measure the impact that virtual bidding has had on forward and spot price convergence in California between April 2009 and March 2014. I find virtual bidding to have caused forward and spot prices to diverge due to the large number of market participants looking to hedge against - or speculate on - the occurrence of infrequent but large spot price spikes by placing virtual demand bids.

  7. A two-layered forward model of tissue for electrical impedance tomography

    International Nuclear Information System (INIS)

    Kulkarni, Rujuta; Saulnier, Gary J; Kao, Tzu-Jen; Newell, Jonathan C; Boverman, Gregory; Isaacson, David

    2009-01-01

    Electrical impedance tomography is being explored as a technique to detect breast cancer, exploiting the differences in admittivity between normal tissue and tumors. In this paper, the geometry is modeled as an infinite half space under a hand-held probe. A forward solution and a reconstruction algorithm for this geometry were developed previously by Mueller et al (1999 IEEE Trans. Biomed. Eng. 46 1379). In this paper, we present a different approach which uses the decomposition of the forward solution into its Fourier components to obtain the forward solution and the reconstructions. The two approaches are compared in terms of the forward solutions and the reconstructions of experimental tank data. We also introduce a two-layered model to incorporate the presence of the skin that surrounds the body area being imaged. We demonstrate an improvement in the reconstruction of a target in a layered medium using this layered model with finite difference simulated data. We then extend the application of our layered model to human subject data and estimate the skin and the tissue admittivities for data collected on the human abdomen using an ultrasound-like hand-held EIT probe. Lastly, we show that for this set of human subject data, the layered model yields an improvement in predicting the measured voltages of around 81% for the lowest temporal frequency (3 kHz) and around 61% for the highest temporal frequency (1 MHz) applied when compared to the homogeneous model

  8. Comparison of visual-based helicopter and fixed-wing forward-looking infrared surveys for counting white-tailed deer Odocoileus virginianus

    Science.gov (United States)

    Storm, Daniel J.; Samuel, Michael D.; Van Deelen, Timothy R.; Malcolm, Karl D.; Rolley, Robert E.; Frost, Nancy A.; Bates, Donald P.; Richards, Bryan J.

    2011-01-01

    Aerial surveys using direct counts of animals are commonly used to estimate deer abundance. Forward-looking infrared (FLIR) technology is increasingly replacing traditional methods such as visual observation from helicopters. Our goals were to compare fixed-wing FLIR and visual, helicopter-based counts in terms of relative bias, influence of snow cover and cost. We surveyed five plots: four 41.4 km2 plots with free-ranging white-tailed deer Odocoileus virginianus populations in Wisconsin and a 5.3 km2 plot with a white-tailed deer population contained by a high fence in Michigan. We surveyed plots using both fixed-wing FLIR and helicopters, both with snow cover and without snow. None of the methods counted more deer than the other when snow was present. Helicopter counts were lower in the absence of snow, but lack of snow cover did not apparently affect FLIR. Group sizes of observed deer were similar regardless of survey method or season. We found that FLIR counts were generally precise (CV = 0.089) when two or three replicate surveys were conducted within a few hours. However, at the plot level, FLIR counts differed greatly between seasons, suggesting that detection rates vary over larger time scales. Fixed-wing FLIR was more costly than visual observers in helicopters and was more restrictive in terms of acceptable survey conditions. Further research is needed to understand what factors influence the detection of deer during FLIR surveys.

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  11. Reflecting on the Present and Looking Ahead: A Response to Shuler

    Science.gov (United States)

    Tobias, Evan S.

    2014-01-01

    In considering how policy work might forward arts education, it is helpful to reflect on the present state of music and arts education while looking ahead at future challenges and possibilities. This response to Shuler's (2001) set of predictions related to music education and policy in the twenty-first century addresses such work in the…

  12. Cardiac resynchronisation therapy in the presence of left-to-right intracardiac shunting: more good than harm?

    Science.gov (United States)

    Kyu, Kyu; Seow, Swee Chong; Wong, Raymond; Kojodjojo, Pipin

    2016-03-17

    An elderly Chinese man with moderately impaired left ventricular function, left bundle branch block and ST-elevation myocardial infarction complicated by ventricular septal rupture had class IV heart failure symptoms refractory to medical and surgical interventions. As a treatment of last resort, a cardiac resynchronisation therapy (CRT) pacemaker was implanted apprehensively, as preoperative concerns were raised whether CRT could exacerbate left-to-right shunting, hence negating the potential benefits of CRT. Introduction of CRT significantly improved the patient's haemodynamic status and symptoms, allowing for successful discharge home. To the best of our knowledge, this is the first report of a patient with severely symptomatic acute heart failure, widened QRS and active left-to-right intracardiac shunting, treated successfully with CRT. 2016 BMJ Publishing Group Ltd.

  13. The economics of restoration: looking back and leaping forward.

    Science.gov (United States)

    Blignaut, James; Aronson, James; de Wit, Martin

    2014-08-01

    Since the publication of the Millennium Ecosystem Assessment in 2005 there has been a surge of interest in ecological restoration (ER) to recover biodiversity, re-establish ecosystem functioning and connectivity, and reactivate the delivery of ecosystem services. In policy spheres, there have also been repeated calls for expansion of restoration efforts. In many countries, new legislation now requires some form of restoration and/or a form of offset investment. All of this will require major increases in financial allocations toward restoration science, technology, and implementation, and much more detailed valuation techniques. The economics of restoration is a new field emerging to support these needs. Our paper here starts with an analysis of the articles and reviews published on this broad subject from 1928 to 2012, as captured in the Scopus academic search platform. Our goal is to present and summarize what has been said and done in this area to date. Next, we map out one possible way forward, illustrated by examples and based on a coherent bundle of decision parameters related to the economics of ER and, more broadly, to the restoration of natural capital. The restoration of natural capital is defined as activities that integrate investment in, and replenishment of, natural capital stocks to improve the flows of ecosystem goods and services, and the preservation of biodiversity, while enhancing all aspects of human well-being. We give special attention to system dynamic approaches and other promising tools and techniques. © 2014 New York Academy of Sciences.

  14. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  15. Inverse vs. forward breast IMRT planning

    International Nuclear Information System (INIS)

    Mihai, Alina; Rakovitch, Eileen; Sixel, Katharina; Woo, Tony; Cardoso, Marlene; Bell, Chris; Ruschin, Mark; Pignol, Jean-Philippe

    2005-01-01

    Breast intensity-modulated radiation therapy (IMRT) improves dose distribution homogeneity within the whole breast. Previous publications report the use of inverse or forward dose optimization algorithms. Because the inverse technique is not widely available in commercial treatment planning systems, it is important to compare the 2 algorithms. The goal of this work is to compare them on a prospective cohort of 30 patients. Dose distributions were evaluated on differential dose-volume histograms using the volumes receiving more than 105% (V 105 ) and 110% (V 110 ) of the prescribed dose, and on the maximum dose (D max ) or hot spot and the sagittal dose gradient (SDG) being the gradient between the dose on inframammary crease and the dose prescribed. The data were analyzed using Wilcoxon signed rank test. The inverse planning significantly improves the V 105 (mean value 9.7% vs. 14.5%, p = 0.002), and the V 110 (mean value 1.4% vs. 3.2%, p = 0.006). However, the SDG is not statistically significantly different for either algorithm. Looking at the potential impact on skin acute reaction, although there is a significant reduction of V 110 using an inverse algorithm, it is unlikely this 1.6% volume reduction will present a significant clinical advantage over a forward algorithm. Both algorithms are equivalent in removing the hot spots on the inframammary fold, where acute skin reactions occur more frequently using a conventional wedge technique. Based on these results, we recommend that both forward and inverse algorithms should be considered for breast IMRT planning

  16. The role of plant physiology in hydrology: looking backwards and forwards

    Science.gov (United States)

    Roberts, J.

    2007-01-01

    conservative? An important contribution both to the similar and low transpiration is the likely reduction of stomatal conductance of the foliage associated with increasing air humidity deficit. A greater response is usually found when initial conductances are highest. Also contributing to similarities in transpiration from forest stands would be a compensatory role of understories and that deficits in soil moisture may not come into play until severe soil water deficits occur. Physiological studies have been conducted in many locations overseas. The modest transpiration of tropical rainforest is intriguing - Why is tropical rainforest transpiration so low? In common with temperate trees the reduction of stomatal conductance of tropical trees in association with increasing air humidity deficit will limit transpiration. In addition the high leaf area index of tropical rainforest creates conditions in the lower canopy layers that mean transpiration from those layers is much reduced from what might be possible. As well as being used to quantify and understand transpiration, physiological techniques might be used to assess when plants require water. What is the first signal that plants need water? Studies on sugar cane in Mauritius indicated that leaf growth was the most sensitive measure. A look forward to the future suggests that there will be a continued need for physiological measurements particularly where other techniques more suited to extensive vegetation are not appropriate. There are many unresolved issues about water use from fragmented, heterogeneous vegetation and physiological approaches are best suited to these. The measurement of sap flow in individual stems will be an important methodology in the future but there are still methodological issues to resolve.

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  19. One-dimensional, forward-forward mean-field games with congestion

    KAUST Repository

    Gomes, Diogo A.

    2017-03-29

    Here, we consider one-dimensional forward-forward mean-field games (MFGs) with congestion, which were introduced to approximate stationary MFGs. We use methods from the theory of conservation laws to examine the qualitative properties of these games. First, by computing Riemann invariants and corresponding invariant regions, we develop a method to prove lower bounds for the density. Next, by combining the lower bound with an entropy function, we prove the existence of global solutions for parabolic forward-forward MFGs. Finally, we construct traveling-wave solutions, which settles in a negative way the convergence problem for forward-forward MFGs. A similar technique gives the existence of time-periodic solutions for non-monotonic MFGs.

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  1. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  2. ISOLDE looks forward

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    The original ISOLDE on-line isotope separator at the CERN 600 MeV Synchro-Cyclotron (SC) was commissioned in 1967 and worked successfully until being essentially rebuilt in 1973/74 at the same time as the SC was upgraded to give higher extracted intensities. Since then there have been continual improvements to practically every aspect of the facility, but two fundamental limitations appeared; the lack of running time for experiments and the lack of space to house those experiments. At the end of the 1970s and the early 1980s, ISOLDE-2 used close to 250 shifts per year but it became clear that this was the maximum the facility could handle. At about this time the CERN management decided the SC should become more and more an accelerator dedicated to ISOLDE experiments, with the aim of doubling the time allocation to 500 shifts per year

  3. ISOLDE looks forward

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1984-11-15

    The original ISOLDE on-line isotope separator at the CERN 600 MeV Synchro-Cyclotron (SC) was commissioned in 1967 and worked successfully until being essentially rebuilt in 1973/74 at the same time as the SC was upgraded to give higher extracted intensities. Since then there have been continual improvements to practically every aspect of the facility, but two fundamental limitations appeared; the lack of running time for experiments and the lack of space to house those experiments. At the end of the 1970s and the early 1980s, ISOLDE-2 used close to 250 shifts per year but it became clear that this was the maximum the facility could handle. At about this time the CERN management decided the SC should become more and more an accelerator dedicated to ISOLDE experiments, with the aim of doubling the time allocation to 500 shifts per year.

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  5. Look-Ahead Strategies Based on Store-Carry and Forward Relaying for Energy Efficient Cellular Communications

    Directory of Open Access Journals (Sweden)

    Panayiotis Kolios

    2010-11-01

    Full Text Available With the increasing availability of Internet type services on mobile devices and the attractive flat rate all-you-can-eat billing system, cellular telecommunication networks are experiencing a tremendous growth in data usage demand. However, there are increasing concerns that current network deployment trends (including more efficient radio access techniques and increased spectrum allocation strategies, will be unable to support the increased Internet traffic in a sustainable way. The delay tolerant nature of mobile Internet traffic allows for a large degree of flexibility in optimizing network performance to meet different design objectives and it’s a feature that has mostly gone unexplored by the research community. In this paper, we introduce a novel message forwarding mechanism in cellular networks that benefits from the inherent delay tolerance of Internet type services to provide flexible and adjustable forwarding strategies for efficient network operation while guaranteeing timely deliveries. By capitalizing on the elasticity of message delivery deadlines and the actual mobility of nodes inside the cell, considerable performance gains can be achieved by physically propagating information messages within the network.

  6. Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Girometti, Rossano; Zanotel, Martina; Londero, Viviana; Bazzocchi, Massimo; Zuiani, Chiara [University of Udine, Azienda Ospedaliero-Universitaria, ' S. Maria della Misericordia' , Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, Udine (Italy)

    2017-09-15

    To evaluate the agreement between automated breast volume scanner (ABVS) and conventional ultrasound (US) as a second-look (SL) tool for assessing additional findings found on MRI. Over a 7-month period, we prospectively assigned to SL-US and SL-ABVS all patients undergoing 1.5 T breast MRI in whom additional findings were found. Five experienced breast radiologists independently interpreted SL-US and SL-ABVS in blinded sessions to evaluate the detection rate of MRI findings and assign them to BI-RADS categories. We calculated the agreement between the two methods in assessing MRI findings as significant (BI-RADS 3-5) versus not significant (BI-RADS 1-2), as well as their cancer detection rate. In a population of 131 patients, SL-ABVS and SL-US showed a comparable detection rate of MRI findings (69.3 vs. 71.5%) (p > 0.05; McNemar test), with an almost perfect agreement in assessing them as significant or not (k = 0.94). This translated into a comparably high cancer detection rate (83.8% for SL-ABVS vs. 87.0% for SL-US). Only 1/31 cancers was missed by SL-ABVS. SL-ABVS and SL-US are nearly equivalent in assessing the significance of MRI findings, leading to a comparable cancer detection rate. SL-ABVS has the potential to replace SL-US in the SL scenario. (orig.)

  7. Comparison between automated breast volume scanner (ABVS) versus hand-held ultrasound as a second look procedure after magnetic resonance imaging

    International Nuclear Information System (INIS)

    Girometti, Rossano; Zanotel, Martina; Londero, Viviana; Bazzocchi, Massimo; Zuiani, Chiara

    2017-01-01

    To evaluate the agreement between automated breast volume scanner (ABVS) and conventional ultrasound (US) as a second-look (SL) tool for assessing additional findings found on MRI. Over a 7-month period, we prospectively assigned to SL-US and SL-ABVS all patients undergoing 1.5 T breast MRI in whom additional findings were found. Five experienced breast radiologists independently interpreted SL-US and SL-ABVS in blinded sessions to evaluate the detection rate of MRI findings and assign them to BI-RADS categories. We calculated the agreement between the two methods in assessing MRI findings as significant (BI-RADS 3-5) versus not significant (BI-RADS 1-2), as well as their cancer detection rate. In a population of 131 patients, SL-ABVS and SL-US showed a comparable detection rate of MRI findings (69.3 vs. 71.5%) (p > 0.05; McNemar test), with an almost perfect agreement in assessing them as significant or not (k = 0.94). This translated into a comparably high cancer detection rate (83.8% for SL-ABVS vs. 87.0% for SL-US). Only 1/31 cancers was missed by SL-ABVS. SL-ABVS and SL-US are nearly equivalent in assessing the significance of MRI findings, leading to a comparable cancer detection rate. SL-ABVS has the potential to replace SL-US in the SL scenario. (orig.)

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  9. Looking ahead

    CERN Multimedia

    2010-01-01

    As I write this, I’m on my way to India for a meeting of the funding agencies for large colliders (FALC), and then on to Korea where I’ll be discussing Korea’s role in our increasingly globalized field. It’s a fitting start to 2010, and to this message, in which I’d like to take a look forward to what we can expect in the year ahead. Enlargement is certainly an issue we’ll be hearing more about this year, with fact-finding missions to the five states that have applied for membership, several countries expressing an interest in associate status and Council due to reach a conclusion on the recommendations of the working group on enlargement. Twelve months from now, CERN will be a different organisation to what it is today. It will have evolved into a form well adapted to carry Europe’s particle-physics banner, coordinating Europe’s involvement in future projects outside the European region while continuing to welcome ...

  10. Engineering ethics: looking back, looking forward.

    Science.gov (United States)

    Burgess, Richard A; Davis, Michael; Dyrud, Marilyn A; Herkert, Joseph R; Hollander, Rachelle D; Newton, Lisa; Pritchard, Michael S; Vesilind, P Aarne

    2013-09-01

    The eight pieces constituting this Meeting Report are summaries of presentations made during a panel session at the 2011 Association for Practical and Professional Ethics (APPE) annual meeting held between March 3rd and 6th in Cincinnati. Lisa Newton organized the session and served as chair. The panel of eight consisted both of pioneers in the field and more recent arrivals. It covered a range of topics from how the field has developed to where it should be going, from identification of issues needing further study to problems of training the next generation of engineers and engineering-ethics scholars.

  11. Five years' experience of the new SAPs: overview and way forward

    International Nuclear Information System (INIS)

    Pape, R.P.

    1998-01-01

    This paper gives an overview of the five years' experience gained in applying the new safety assessment principles (SAPs). Beginning with a brief history of SAPs, it goes on to discuss their structure and their relevance to safety matters. It develops some of the more basic issues which users have to bear in mind and also considers how SAPs are used by NII. Finally, there is a look forward to future developments in SAPs usage and application. (author)

  12. The effectiveness of FDG PET/CT for evaluation of intracardiac mass and pericardiac lesions

    International Nuclear Information System (INIS)

    Hwang, H. S; Yun, M. J.; Lee, J. D

    2004-01-01

    Fluorodeoxyglucose positron emission tomography has been known to be useful in diagnosis and staging of malignancy. FDG PET has high sensitivity and easily detects malignant lesions that are missed and overlooked in anatomic imaging modality. We assessed the impact of FDG PET/CT compared to echocardiogram and enhanced CT scan. Five patients of intra- and pericardiac lesions were included in this study. All patients underwent PET/CT(GE Discovery ST), enhanced CT scan and echocardiogram. Two patients were non-small cell lung cancer, one of RV metastatic mass, the other of pericardial metastasis in RV region. One of melanoma with systemic metastases, had RA malignant masses. One of suspicious lung cancer and intracardiac mass, has proved to benign LA thrombosis. One of lymphoma showed suspicious cardiac mass, but revealed no abnormality in echocardiogram. FDG PET/CT is sensitive and useful method to detect intra- and pericardiac mass in patients with suspected malignancy. All patients except lymphoma were correctly diagnosed using FDG PET/ICT

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  15. Intracardiac foreign body resulting from a transmediastinal gunshot mimics an extracardiac foreign body: An image presentation

    Directory of Open Access Journals (Sweden)

    Hsun-Yi Fu

    2017-10-01

    Full Text Available A transmediastinal gunshot wound (TMGW is one of the most severe traumatic injuries, with a high mortality rate. Prompt diagnosis and emergency surgical intervention with or without cardiopulmonary bypass are usually required to save lives. We report a particular case of TMGW in which the computed tomography imaging findings indicated an extracardiac foreign body. However, intraoperative findings revealed an intracardiac foreign body, and urgent cardiopulmonary bypass was performed to remove the foreign body. We suggest that cardiopulmonary bypass should be on standby during an exploratory sternotomy for TMGW, when the trajectory of the bullet hints at a cardiac-penetrating injury according to imaging studies and the location of the bullet remains unaffected by the patient's postural changes.

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  17. Detection of Asymptomatic Renal Calcifications in Astronauts Using a Novel Ultrasound Protocol

    Science.gov (United States)

    Garcia, Kathleen; Sargsyan, Ashot; Reyes, David; Locke, James

    2017-01-01

    Ultrasound (US) specifically looking for asymptomatic renal calcifications that may be renal stones is typically not done in the terrestrial setting. Standard abdominal US without a renal focus may discover incidental, mineralized renal material (MRM); however punctate solid areas of MRM is less than 3 mm are usually considered subclinical. Detecting these early calcifications before they become symptomatic renal stones is critical to prevent adverse medical and mission outcomes during spaceflight.

  18. Risk Factors for Intracardiac Thrombosis in the Right Atrium and Superior Vena Cava in Critically Ill Neonates who Required the Installation of a Central Venous Catheter

    Directory of Open Access Journals (Sweden)

    Alfredo Ulloa-Ricardez

    2016-08-01

    Conclusion: This study allowed us to identify several contributing factors to the development of intracardiac thrombosis in the RA and SVC related to the installation of a CVC in a subgroup of critically ill neonates. Multicenter and well-designed studies with a larger number of patients could help validate our findings and/or identify other risk factors that were not identified in the present study.

  19. Gaze position modulates the effectiveness of forward collision warnings for drowsy drivers.

    Science.gov (United States)

    Gaspar, John G; Schwarz, John-Chris W; Brown, Timothy L; Kang, Julie

    2017-12-22

    Advanced driver assistance systems (ADAS) have the potential to prevent crashes and reduce their severity. Forward collision warnings (FCW) are quickly becoming standard across vehicle lineups and may prevent frontal crashes by alerting drivers. Previous research has demonstrated the effectiveness of FCW for distracted drivers, but their effectiveness for other types of impairment remains unknown. Like distraction, drowsiness can impair driver response time and lead to crashes. The goal of the present study was to evaluate the effectiveness of FCW for moderately and severely drowsy drivers using a high-fidelity driving simulator. Drowsy drivers were divided into three warning conditions during a revealed stop vehicle forward collision event: An auditory alert, a haptic seat vibration, and a no warning baseline. Results indicate that FCW were effective at speeding drowsy driver response, but only when the drowsy drivers were looking away from the forward roadway at the onset of the event. These results have important implications for ADAS technology and driver state monitoring systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Pilot Overmyer looks over food selections and experiments with beverage

    Science.gov (United States)

    1982-01-01

    Pilot Overmyer, using beverage container and drinking straw secured in meal tray assembly (ASSY), experiments with microgravity chararcteristics of liquid on middeck in front of forward lockers. Overmyer also looks over packages of food attached to middeck lockers in meal tray assemblies. Carry-on food warmer appears overhead and other meal tray assemblies, personal hygiene mirror assy, personal hygiene kit, and portrait of G.W.S. Abbey, JSC's Director of Flight Operations, appear on lockers.

  1. Toward in vivo detection of hydrogen peroxide with ultrasound molecular imaging

    Science.gov (United States)

    Olson, Emilia S.; Orozco, Jahir; Wu, Zhe; Malone, Christopher D.; Yi, Boemha; Gao, Wei; Eghtedari, Mohammad; Wang, Joseph; Mattrey, Robert F.

    2013-01-01

    We present a new class of ultrasound molecular imaging agents that extend upon the design of micromotors that are designed to move through fluids by catalyzing hydrogen peroxide (H2O2) and propelling forward by escaping oxygen microbubbles. Micromotor converters require 62 mm of H2O2 to move – 1000-fold higher than is expected in vivo. Here, we aim to prove that ultrasound can detect the expelled microbubbles, to determine the minimum H2O2 concentration needed for microbubble detection, explore alternate designs to detect the H2O2 produced by activated neutrophils and perform preliminary in vivo testing. Oxygen microbubbles were detected by ultrasound at 2.5 mm H2O2. Best results were achieved with a 400–500 nm spherical design with alternating surface coatings of catalase and PSS over a silica core. The lowest detection limit of 10–100 µm was achieved when assays were done in plasma. Using this design, we detected the H2O2 produced by freshly isolated PMA-activated neutrophils allowing their distinction from naïve neutrophils. Finally, we were also able to show that direct injection of these nanospheres into an abscess in vivo enhanced ultrasound signal only when they contained catalase, and only when injected into an abscess, likely because of the elevated levels of H2O2 produced by inflammatory mediators. PMID:23958028

  2. A new look at the comparative physiology of insect and human hearts.

    Science.gov (United States)

    Sláma, Karel

    2012-08-01

    Recent electrocardiographic (ECG) studies of insect hearts revealed the presence of human-like, involuntary and purely myogenic hearts. Certain insects, like a small light-weight species of hoverfly (Episyrphus balteatus), have evolved a very efficient cardiac system comprised of a compact heart ventricle and a narrow tube of aorta, which evolved as an adaptation to sustained hovering flights. Application of thermocardiographic and optocardiographic ECG methods revealed that adult flies of this species use the compact muscular heart chamber (heart ventricle) for intensive pumping of insect "blood" (haemolymph) into the head and thorax which is ringed all over with indirect flight musculature. The recordings of these hearts revealed extremely high, record rates of forward-directed, anterograde heartbeat (up to 10Hz), associated with extremely enhanced synchronic (not peristaltic) propagation of systolic myocardial contractions (32.2mm/s at room temperature). The relatively slow, backward-directed or retrograde cardiac contractions occurred only sporadically in the form of individual or twinned pulses replacing occasionally the resting periods. The compact heart ventricle contained bi-directional lateral apertures, whose opening and closure diverted the intracardiac anterograde "blood" streams between the abdominal haemocoelic cavity and the aortan artery, respectively. The visceral organs of this flying machine (crop, midgut) exhibited myogenic, extracardiac peristaltic pulsations similar to heartbeat, including the periodically reversed forward and backward direction of the peristaltic waves. The tubular crop contracted with a periodicity of 1Hz, both forwards and backwards, with propagation of the peristaltic waves at 4.4mm/s. The air-inflated and blindly ended midgut contracted at 0.2Hz, with a 0.9mm/s propagation of the peristaltic contraction waves. The neurogenic system of extracardiac haemocoelic pulsations, widely engaged in the regulation of circulatory and

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are ... Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... What are the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and ... be heard with every heartbeat. top of page What are some common uses of the procedure? Ultrasound ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures of the inside of ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart ... Articles and Media Angioplasty and Vascular Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... kidneys. There are three types of Doppler ultrasound: Color Doppler uses a computer to convert Doppler measurements ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is ...

  12. Musculoskeletal ultrasound in rheumatology in Korea: targeted ultrasound initiative survey.

    Science.gov (United States)

    Kang, Taeyoung; Wakefield, Richard J; Emery, Paul

    2016-04-01

    In collaboration with the Targeted Ultrasound Initiative (TUI), to conduct the first study in Korea to investigate current practices in ultrasound use among Korean rheumatologists. We translated the TUI Global Survey into Korean and added questions to better understand the specific challenges facing rheumatologists in Korea. To target as many rheumatologists in Korea as possible, we created an on-line version of this survey, which was conducted from March to April 2013. Rheumatologists are in charge of ultrasound in many Korean hospitals. Rheumatologists in hospitals and private clinics use ultrasound to examine between one and five patients daily; they use ultrasound for diagnosis more than monitoring and receive compensation of about US$30-50 per patient. There are marked differences in the rates of ultrasound usage between rheumatologists who work in private practice compared with tertiary hospitals. Korean rheumatologists not currently using ultrasound in their practice appear eager to do so. This survey provides important insights into the current status of ultrasound in rheumatology in Korea and highlights several priorities; specifically, greater provision of formal training, standardization of reporting and accrual of greater experience among ultrasound users. If these needs are addressed, all rheumatology departments in Korea are likely to use ultrasound or have access to it in the future. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  13. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hirtler, Daniel [University Hospital Freiburg, Department of Congenital Heart Defects and Pediatric Cardiology (Heart Center, University of Freiburg), Freiburg (Germany); Garcia, Julio; Barker, Alex J. [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Geiger, Julia [University Childrens' Hospital Zurich, Department of Radiology, Zurich (Switzerland)

    2016-10-15

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p < 0.05). The main pulmonary artery (MPA) regurgitant flow was associated with higher RA and RV vorticity, which was significant for RA maximum and RV mean vorticity (p = 0.01/0.03). The calculation of vorticity based on 4D flow data is an alternative approach to assess intracardiac flow changes in rTOF patients compared with qualitative flow visualization. Alterations in intracardiac vorticity could be relevant with regard to the development of RV dilation and impaired function. (orig.)

  14. Assessment of intracardiac flow and vorticity in the right heart of patients after repair of tetralogy of Fallot by flow-sensitive 4D MRI

    International Nuclear Information System (INIS)

    Hirtler, Daniel; Garcia, Julio; Barker, Alex J.; Geiger, Julia

    2016-01-01

    To comprehensively and quantitatively analyse flow and vorticity in the right heart of patients after repair of tetralogy of Fallot (rTOF) compared with healthy volunteers. Time-resolved flow-sensitive 4D MRI was acquired in 24 rTOF patients and 12 volunteers. Qualitative flow evaluation was based on consensus reading of two observers. Quantitative analysis included segmentation of the right atrium (RA) and ventricle (RV) in a four-chamber view to extract volumes and regional haemodynamic information for computation of regional mean and peak vorticity. Right heart intra-atrial, intraventricular and outflow tract flow patterns differed considerably between rTOF patients and volunteers. Peak RA and mean RV vorticity was significantly higher in patients (p = 0.02/0.05). Significant negative correlations were found between patients' maximum and mean RV and RA vorticity and ventricular volumes (p < 0.05). The main pulmonary artery (MPA) regurgitant flow was associated with higher RA and RV vorticity, which was significant for RA maximum and RV mean vorticity (p = 0.01/0.03). The calculation of vorticity based on 4D flow data is an alternative approach to assess intracardiac flow changes in rTOF patients compared with qualitative flow visualization. Alterations in intracardiac vorticity could be relevant with regard to the development of RV dilation and impaired function. (orig.)

  15. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  17. Degradation of Acid Blue 25 in aqueous media using 1700kHz ultrasonic irradiation: ultrasound/Fe(II) and ultrasound/H(2)O(2) combinations.

    Science.gov (United States)

    Ghodbane, Houria; Hamdaoui, Oualid

    2009-06-01

    In this work, the sonolytic degradation of an anthraquinonic dye, C.I. Acid Blue 25 (AB25), in aqueous phase using high frequency ultrasound waves (1700kHz) for an acoustic power of 14W was investigated. The sonochemical efficiency of the reactor was evaluated by potassium iodide dosimeter, Fricke reaction and hydrogen peroxide production yield. The three investigated methods clearly show the production of oxidizing species during sonication and well reflect the sonochemical effects of high frequency ultrasonic irradiation. The effect of operational conditions such as the initial AB25 concentration, solution temperature and pH on the degradation of AB25 was studied. Additionally, the influence of addition of salts on the degradation of dye was examined. The rate of AB25 degradation was dependent on initial dye concentration, pH and temperature. Addition of salts increased the degradation of dye. Experiments conducted using distilled and natural waters demonstrated that the degradation was more efficient in the natural water compared to distilled water. To increase the efficiency of AB25 degradation, experiments combining ultrasound with Fe(II) or H(2)O(2) were conducted. Fe(II) induced the dissociation of ultrasonically produced hydrogen peroxide, leading to additional OH radicals which enhance the degradation of dye. The combination of ultrasound with hydrogen peroxide looks to be a promising option to increase the generation of free radicals. The concentration of hydrogen peroxide plays a crucial role in deciding the extent of enhancement obtained for the combined process. The results of the present work indicate that ultrasound/H(2)O(2) and ultrasound/Fe(II) processes are efficient for the degradation of AB25 in aqueous solutions by high frequency ultrasonic irradiation.

  18. Assessment of vasodilator therapy in patients with severe congestive heart failure: limitations of measurements of left ventricular ejection fraction and volumes

    International Nuclear Information System (INIS)

    Firth, B.G.; Dehmer, G.J.; Markham, R.V. Jr.; Willerson, J.T.; Hillis, L.D.

    1982-01-01

    Although noninvasive techniques are often used to assess the effect of vasodilator therapy in patients with congestive heart failure, it is unknown whether changes in noninvasively determined left ventricular ejection fraction, volume, or dimension reliably reflect alterations in intracardiac pressure and flow. Accordingly, we compared the acute effect of sodium nitroprusside on left ventricular volume and ejection fraction (determined scintigraphically) with its effect on intracardiac pressure and forward cardiac index (determined by thermodilution) in 12 patients with severe, chronic congestive heart failure and a markedly dilated left ventricle. Nitroprusside (infused at 1.3 +/- 1.1 [mean +/- standard deviation] microgram/kg/min) caused a decrease in mean systemic arterial, mean pulmonary arterial, and mean pulmonary capillary wedge pressure as well as a concomitant increase in forward cardiac index. Simultaneously, left ventricular end-diastolic and end-systolic volume indexes decreased, but the scintigraphically determined cardiac index did not change significantly. Left ventricular ejection fraction averaged 0.19 +/- 0.05 before nitroprusside administration and increased by less than 0.05 units in response to nitroprusside in 11 of 12 patients. The only significant correlation between scintigraphically and invasively determined variables was that between the percent change in end-diastolic volume index and the percent change in pulmonary capillary wedge pressure (r . 0.68, p . 0.01). Although nitroprusside produced changes in scintigraphically determined left ventricular ejection fraction, end-systolic volume index, and cardiac index, these alterations bore no predictable relation to changes in intracardiac pressure, forward cardiac index, or vascular resistance. Furthermore, nitroprusside produced a considerably greater percent change in the invasively measured variables than in the scintigraphically determined ones

  19. USAID Forward

    Data.gov (United States)

    US Agency for International Development — The USAID Forward reform initiative ran from 2010-2016. USAID Forward improved the way that the Agency delivers foreign assistance by embracing new partnerships,...

  20. Evaluation of tele-ultrasound as a tool in remote diagnosis and clinical management at the Amundsen-Scott South Pole Station and the McMurdo Research Station.

    Science.gov (United States)

    Otto, Christian; Shemenski, Ron; Scott, Jessica M; Hartshorn, Jeanette; Bishop, Sheryl; Viegas, Steven

    2013-03-01

    Abstract Background: A large number of Antarctic stations do not utilize ultrasound for medical care. Regular use of ultrasound imaging at South Pole and McMurdo Stations first began in October 2002. To date, there has been no evaluation of medical events requiring ultrasound examination from this remote environment. Additionally, the importance of tele-ultrasound for clinical management in Antarctica has not yet been assessed. We therefore conducted a retrospective analysis of all ultrasound exams performed at South Pole and McMurdo Stations between October 2002 and October 2003. Radiology reports and patient charts were reviewed for pre- and post-ultrasound diagnosis and treatment. Sixty-six ultrasound exams were conducted on 49 patients. Of the exams, 94.0% were interpreted by the store-and-forward method, whereas 6.0% were interpreted in "real-time" format. Abdominal, genitourinary, and gynecology ultrasound exams accounted for 63.6% of exams. Ultrasound examination prevented an intercontinental aeromedical evacuation in 25.8% of cases, and had a significant effect on the diagnosis and management of illness in patients at South Pole and McMurdo research stations. These findings indicate that diagnostic ultrasound has significant benefits for medical care at Antarctic stations and that tele-ultrasound is a valuable addition to remote medical care for isolated populations with limited access to tertiary-healthcare facilities.

  1. Comparison of ultrasound evaluation of patients of obstructive jaundice with endoscopic retrograde cholangio-pancreatography findings

    International Nuclear Information System (INIS)

    Farrukh, S.Z.U.I.; Siddiqui, A.R.; Haqqi, S.A.; Muhammad, A.J.

    2017-01-01

    Ultrasonography has proven to be quite effective in differentiating hepatocellular from obstructive cause of jaundice in various studies. This study was conducted with the aim to determine the efficacy of ultrasonography and Endoscopic Retrograde Cholangio-Pancreatography (ERCP) in the diagnosis of obstructive reason of jaundice. Methods: In this descriptive case series, 200 patients with >15 years age of either gender with cholestatic liver enzymes were included, i.e., those patients who had an ultrasound prior to ERCP at the department of gastroenterology of Patel Hospital, Karachi. Patients known to have liver disease with cholestatic jaundice had imaging other than ultrasound were excluded. The results of ultrasonography and ERCPs were compared in particularly looking for the cause of obstruction. Results: Out of total 200 patients, mean age was 41.22+-12.46 years with 107 (53.5 percent) females. Ability of ultrasound in correctly diagnosing obstructive reason for stone CBD was found to be 72.5 percent, dilated CBD without reason 41.7 percent, proximal obstruction, 63.15 percent, distal CBD obstruction 60 percent, and sludge 66.7 percent. Overall ability of ultrasound in correctly diagnosing the cause of obstruction was 64.17 percent. Conclusion: Ultrasound is recommended as the initial examination, which provides a guide to choose patients for either a more advanced non-invasive imaging like MRCP or to an invasive procedure like ERCP. (author)

  2. Traumatic Brain Injury: Looking Back, Looking Forward

    Science.gov (United States)

    Bartlett, Sue; Lorenz, Laura; Rankin, Theresa; Elias, Eileen; Weider, Katie

    2011-01-01

    This article is the eighth of a multi-part series on traumatic brain injury (TBI). Historically, TBI has received limited national attention and support. However, since it is the signature injury of the military conflicts in Iraq and Afghanistan, TBI has gained attention of elected officials, military leaders, policymakers, and the public. The…

  3. Looking Backward, Looking Forward: MLA Members Speak

    OpenAIRE

    Alliston, April; Ammons, Elizabeth; Arnold, Jean; Baym, Nina; Beckett, Sandra L; Beidler, Peter G; Berger, Roger A; Bermann, Sandra; Wilson, J. J; Boone, Troy; Booth, Alison; Booth, Wayne C; Phelan, James; Borroff, Marie; Hassan, Ihab

    2000-01-01

    In 1997 I was asked to organize humanities outreach activities at the University of California, Irvine. The result was the formation of Humanities Out There (HOT). In our workshops, faculty members and graduate students supervise teams of undergraduates in order to take the methods and materials of the university into the larger community. I believe that programs like these will  become increasingly important in the next century, as economic, cultural, and educational divisions deepe...

  4. Prisoner research - looking back or looking forward?

    Science.gov (United States)

    Thomas, David L

    2010-01-01

    Much has been written about prisoner research and the controversies surrounding prisoners as human subjects. The Institute of Medicine recently released a report addressing some of these issues. This report, which generated further controversy, needs to be fully discussed in the literature and certain aspects are examined in this work. Further, in the body of literature there has been little acknowledgement of the concept of the right of prisoners to be involved in research. This needs to be pursued from an ethical perspective and eventually a legal one. This paper explores that concept and documents some facilities in which a prisoner's right to research has occurred.

  5. Surgical Oncology Nursing: Looking Back, Looking Forward.

    Science.gov (United States)

    Crane, Patrick C; Selanders, Louise

    2017-02-01

    To provide a historical perspective in the development of oncology nursing and surgical oncology as critical components of today's health care system. Review of the literature and Web sites of key organizations. The evolution of surgical oncology nursing has traversed a historical journey from that of a niche subspecialty of nursing that had very little scientific underpinning, to a highly sophisticated discipline within a very short time. Nursing continues to contribute its expertise to the encyclopedic knowledge base of surgical oncology and cancer care, which have helped improve the lives of countless patients and families who have had to face the difficulties of this diagnosis. An understanding of the historical context for which a nursing specialty such as surgical oncology nursing evolves is critical to gaining an appreciation for the contributions of nursing. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Effect of modulated ultrasound parameters on ultrasound-induced thrombolysis

    International Nuclear Information System (INIS)

    Soltani, Azita; Volz, Kim R; Hansmann, Doulas R

    2008-01-01

    The potential of ultrasound to enhance enzyme-mediated thrombolysis by application of constant operating parameters (COP) has been widely demonstrated. In this study, the effect of ultrasound with modulated operating parameters (MOP) on enzyme-mediated thrombolysis was investigated. The MOP protocol was applied to an in vitro model of thrombolysis. The results were compared to a COP with the equivalent soft tissue thermal index (TIS) over the duration of ultrasound exposure of 30 min (p -2 ± 0.01 μm and 1.99 x 10 -2 ± 0.004 μm, respectively (p < 0.74). No signatures of inertial or stable cavitation were observed for either acoustic protocol. In conclusion, due to mechanisms other than cavitation, application of ultrasound with modulated operating parameters has the potential to significantly enhance the relative lysis enhancement compared to application of ultrasound with constant operating parameters.

  7. Advantages and disadvantages of 3D ultrasound of thyroid nodules including thin slice volume rendering

    Directory of Open Access Journals (Sweden)

    Slapa Rafal

    2011-01-01

    Full Text Available Abstract Background The purpose of this study was to assess the advantages and disadvantages of 3D gray-scale and power Doppler ultrasound, including thin slice volume rendering (TSVR, applied for evaluation of thyroid nodules. Methods The retrospective evaluation by two observers of volumes of 71 thyroid nodules (55 benign, 16 cancers was performed using a new TSVR technique. Dedicated 4D ultrasound scanner with an automatic 6-12 MHz 4D probe was used. Statistical analysis was performed with Stata v. 8.2. Results Multiple logistic regression analysis demonstrated that independent risk factors of thyroid cancers identified by 3D ultrasound include: (a ill-defined borders of the nodule on MPR presentation, (b a lobulated shape of the nodule in the c-plane and (c a density of central vessels in the nodule within the minimal or maximal ranges. Combination of features provided sensitivity 100% and specificity 60-69% for thyroid cancer. Calcification/microcalcification-like echogenic foci on 3D ultrasound proved not to be a risk factor of thyroid cancer. Storage of the 3D data of the whole nodules enabled subsequent evaluation of new parameters and with new rendering algorithms. Conclusions Our results indicate that 3D ultrasound is a practical and reproducible method for the evaluation of thyroid nodules. 3D ultrasound stores volumes comprising the whole lesion or organ. Future detailed evaluations of the data are possible, looking for features that were not fully appreciated at the time of collection or applying new algorithms for volume rendering in order to gain important information. Three-dimensional ultrasound data could be included in thyroid cancer databases. Further multicenter large scale studies are warranted.

  8. Forward optical glory

    International Nuclear Information System (INIS)

    Nussenzveig, H.M.

    Forward optical glory effects in Mie scattering are displayed here for the first time. These effects include regular oscillations in Mie efficiency factors and characteristic deviations from zero polarization in near-forward scattering which are observable for real refractive indices near √2 and 2. Complex angular momentum theory predicts the period of oscillation correctly and shows the important role played by surface waves with shortcuts through the sphere. three possible types of experiments for detecting the forward glory are proposed, involving measurements of extinction, radiation pressure, and polarization in near-forward scattering. (Author) [pt

  9. Fifty years in fusion and the way forward

    International Nuclear Information System (INIS)

    Jacquinot, J.

    2010-01-01

    This particular 'Fusion Pioneers Memorial lecture' was given 50 years after the first historical FEC conference in 1958. It was a unique occasion to perform a global reflection on thermonuclear fusion which is summarized in this paper. We first consider the case for fusion energy then move on to the scientific achievements during the past five decades. Finally, the lessons drawn from the past give a framework to consider the challenges ahead of us. The 1958 pioneers had the vision of the vital importance of international collaboration to succeed in this unique endeavour. Fifty years later, this vision has amply proven its worth. Looking at the way forward, this vision constitutes a strong basis to harness fusion energy in the decades to come.

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ... Ultrasound examinations are painless and easily tolerated by most patients. Ultrasound exams in which the transducer is ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... D images. A Doppler ultrasound study may be part of an ultrasound examination. Doppler ultrasound , also called ... terms of the distance traveled per unit of time, rather than as a color picture. It can ...

  14. Intra-cardiac masses in adults: A review of echocardiogram records ...

    African Journals Online (AJOL)

    2012-12-04

    Dec 4, 2012 ... TTE is the clinical procedure of choice for identification of left ventricular thrombi. TTE has ... The first effort to use pulse‑reflected ultrasound to examine .... masses was in a patient with lymphoma [Figures 5 and 6]. Table 1: Demographic characteristics of the patients and location of masses. Case number.

  15. Malaysian Journal of Medical Sciences: A Step Forward towards an International Journal

    Science.gov (United States)

    Ghazli, Nur Farahin; Che Annual, Norfatiha; Abdullah, Jafri Malin

    2015-01-01

    In 1986, the Malaysian Journal of Medical Sciences (MJMS) began as the small and newly established journal Diagnosa, established by the Universiti Sains Malaysia School of Medicine. After 28 years in the publishing industry, we have received the honor of a listing as a local journal in the Emerging Sources Citation Index (ESCI) created by Thomson Reuters (TR) to spotlight emerging high-quality scientific publications. The editorial team of MJMS looks forward to the next step in the march of progress toward the status of an international journal. PMID:28223878

  16. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  17. A forward looking company

    International Nuclear Information System (INIS)

    Christian, David A.

    2004-01-01

    The article is an excerpt of an interview with David A. Christian, Senior Vice President-Nuclear and Chief Nuclear Officer, Dominion Generation conducted at NEI's Nuclear Energy Assembly in New Orleans, Louisiana on 13 May 2004. It highlights the company's energy diversity, and in particular, activities related to early-site permits and possible future plans for nuclear power plant development in the U.S. The interview touches on questions related to the Consortium (composed of Dominion, AECL Technologies, the U.S. subsidiary of AECL, Hatachi America and Bechtel Power Corp.) and the DOE financial support involved (approximately 50%) along with comments related to job impacts, energy security and climate change impacts, human resource issues (particularly about getting high school students interested in jobs related to the nuclear industry) and public policy. The interview ends with a discussion of investment interest and the state of standardization in the industry

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  19. Low-Grade Endometrial Stromal Sarcoma with Intravenous and Intracardiac Extension: A Multidisciplinary Approach

    Directory of Open Access Journals (Sweden)

    Wataru Kudaka

    2016-01-01

    Full Text Available Background. A rare case of low-grade endometrial stromal sarcoma (LG-ESS extending to inferior vena cava (IVC and cardiac chambers. Case Report. A 40-year-old woman had IVC tumor, which was incidentally detected by abdominal ultrasonography during a routine medical checkup. CT scan revealed a tumor in IVC, right iliac and ovarian veins, which was derived from the uterus and extended into the right atrium and ventricle. The operation was performed, the heart and IVC were exposed, and cardiopulmonary bypass was initiated. A right atriotomy was performed, and the intracardiac mass was removed. Then the tumor in IVC and the right internal iliac vein were removed after longitudinal venotomies in the suprarenal and infrarenal vena cava, the right common iliac vein. Next the pelvis was explored. Tumors were found originating from the posterior wall of the uterus and continuing into both the right uterine and ovarian vein. The patient underwent total hysterectomy with bilateral salpingooophorectomy. Complete tumor resection was achieved. Histopathological analysis confirmed a diagnosis of LG-ESS. She showed no evidence of disease for 2 years and 3 months. Conclusions. Our case highlights the importance of a multidisciplinary approach in treating this rare cardiovascular pathological condition through preoperative assessment to final operation.

  20. Indium-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Michio; Ojima, Kenji; Tsuda, Takashi [Niigata Univ. (Japan). School of Medicine

    1983-09-01

    This study was designed to evaluate the efficacy of scintigraphy by using /sup 111/In-oxine labeled platelets for the detection of either intracardiac or intravascular thrombi. Fourteen cases of thrombi diagnosed or suspected on the basis of either angiography or two-dimensional echography were examined. They included four cases of left ventricular thrombi, three of left atrial thrombi, four of vascular thrombi and three of inflammatory disease. Platelet samples from the patients were labeled by /sup 111/In-oxine according to the method originated by Yui et al. The labeling efficiency was 72.4+-9.8%. The platelets retained good function except for collagen aggregability. Hot areas of high quality in the scintigram were demonstrated in six cases including two with left ventricular thrombi, two with left atrial thrombi and two with vascular thrombi. These areas accorded well with the findings of angiography, echography or surgery. The removed thrombi had a layer of aggregated platelets on the surface. Platelet survival was shortened in a case of prosthetic valve endocarditis without a hot area, and was normal in four out of the five cases including two with a hot area. It is concluded that this method is potentially predictive in detecting thrombi.

  1. Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

    Science.gov (United States)

    Ben Daya, Ibrahim; Chen, Albert I H; Shafiee, Mohammad Javad; Wong, Alexander; Yeow, John T W

    2017-09-06

    The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system's potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of General Ultrasound Imaging? Ultrasound waves are ...

  3. Clinical diagnostic ultrasound

    International Nuclear Information System (INIS)

    Barnett, E.; Morley, P.

    1986-01-01

    This textbook on diagnostic ultrasound covers the main systems, with emphasis being placed on the clinical application of diagnostic ultrasound in everyday practice. It provides not only a textbook for postgraduates (particularly FRCR candidates), but also a reference work for practitioners of clinical ultrasound and clinicians generally

  4. Comparison of forward and backward pp pair knockout in 3He(e,e'pp)n

    Science.gov (United States)

    Baghdasaryan, H.; Weinstein, L. B.; Laget, J. M.; Adhikari, K. P.; Aghasyan, M.; Amaryan, M. J.; Anghinolfi, M.; Ball, J.; Battaglieri, M.; Biselli, A. S.; Briscoe, W. J.; Brooks, W. K.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Charles, G.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Daniel, A.; Dashyan, N.; De Sanctis, E.; De Vita, R.; Djalali, C.; Dodge, G. E.; Doughty, D.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Elouadrhiri, L.; Fedotov, G.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Gohn, W.; Gothe, R. W.; Griffioen, K. A.; Guegan, B.; Guidal, M.; Hafidi, K.; Hicks, K.; Hyde, C. E.; Ireland, D. G.; Ishkhanov, B. S.; Jenkins, D.; Jo, H. S.; Joo, K.; Khandaker, M.; Khetarpal, P.; Kim, A.; Kim, W.; Kubarovsky, A.; Kubarovsky, V.; Kuhn, S. E.; Kuleshov, S. V.; Kvaltine, N. D.; Lu, H. Y.; MacGregor, I. J. D.; McKinnon, B.; Mirazita, M.; Mokeev, V.; Moutarde, H.; Munevar, E.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Paolone, M.; Pappalardo, L. L.; Paremuzyan, R.; Park, K.; Park, S.; Pisano, S.; Pozdniakov, S.; Procureur, S.; Raue, B. A.; Ricco, G.; Rimal, D.; Ripani, M.; Rosner, G.; Rossi, P.; Saini, M. S.; Saylor, N. A.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Smith, E. S.; Sober, D. I.; Sokan, D.; Stepanyan, S. S.; Stepanyan, S.; Strauch, S.; Taiuti, M.; Tang, W.; Tkachenko, S.; Voskanyan, H.; Voutier, E.; Wood, M. H.; Zana, L.; Zhao, B.

    2012-06-01

    Measuring nucleon-nucleon short range correlations (SRCs) has been a goal of the nuclear physics community for many years. They are an important part of the nuclear wave function, accounting for almost all of the high-momentum strength. They are closely related to the EMC effect. While their overall probability has been measured, measuring their momentum distributions is more difficult. In order to determine the best configuration for studying SRC momentum distributions, we measured the 3He(e,e'pp)n reaction, looking at events with high-momentum protons (pp>0.35 GeV/c) and a low-momentum neutron (pn<0.2 GeV/c). We examined two angular configurations: either both protons emitted forward or one proton emitted forward and one backward (with respect to the momentum transfer, q⃗). The measured relative momentum distribution of the events with one forward and one backward proton was much closer to the calculated initial-state pp relative momentum distribution, indicating that this is the preferred configuration for measuring SRC.

  5. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  6. Standards of the Polish Ultrasound Society – update. Ultrasound examination of thyroid gland and ultrasound-guided thyroid biopsy

    Directory of Open Access Journals (Sweden)

    Anna Trzebińska

    2014-03-01

    Full Text Available Ultrasonography is a primary imaging technique in patients with suspected thyroid disease. It allows to assess the location, size and echostructures of the thyroid gland as well as detect focal lesions, along with indication of their size, echogenicity, echostructure and vascularity. Based on these features, ultrasound examination allows to predict abnormal focal lesions for biopsy and monitor the biopsy needle track. This paper presents the standards of thyroid ultrasound examination regarding ultrasound apparatus technical requirements, scanning techniques, readings, measurements, and the description of the examination. It discusses the ultrasound features of increased malignancy risk in focal lesions (nodules found in the thyroid gland. It presents indications for fine needle aspiration biopsy of the thyroid gland for the visibility of single nodules (focal lesions and numerous lesions as well as discusses contraindications for thyroid biopsy. It describes the biopsy technique, possible complications and rules for post-biopsy monitoring of benign lesions. The paper is an update of the Standards of the Polish Ultrasound Society issued in 2011. It has been prepared on the basis of current literature, taking into account the information contained in the following publications: Thyroid ultrasound examination and Recommendations of the Polish Ultrasound Society for the performance of the FNAB of the thyroid.

  7. Building a forward: Looking agenda for transitional justice in South Africa

    Directory of Open Access Journals (Sweden)

    van der Merwe Hugo

    2005-01-01

    Full Text Available A more holistic restorative justice process provides an avenue to untangle the web of political, personal and social dynamics that deal with past and future sources of violent conflict. While much of the restorative justice literature is focused on individual healing and personal responsibility, the challenge we face in South Africa is to deal with past human rights abuses in a social context that also recognizes their present relevance. As we look at rebuilding society, we face new challenges in relation to social violence. These challenges (be they political divisions, criminal violence, gender violence have their roots in the way that our society has created social identities in the past, the tools we have developed for dealing with violence and the unresolved memories of trauma, exclusion and mistrust we inherit from that past. Sometimes this specter of the past subtly shapes our sense of who we are and what our options are, but all too often it also directly intrudes through drawing on old enmities, repeating old but re-legitimated patterns of violence. Building a new society requires transitional justice processes that don’t simply pigeonhole pre- and post-transition conflicts in neat packages to be set aside or adjudicated. The continuities of conflict and violence require an approach that engages with the causes as well as the complex manifestations of our history of social dislocation and disruption.

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is used to evaluate the: bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ultrasound transducer into ...

  9. Obstetrical Ultrasound

    Science.gov (United States)

    ... heartbeat can be seen as an ongoing ultrasound movie. Ultrasound devices also use Doppler, a special application ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  10. Ultrasound in the investigation of posterior compartment vaginal prolapse and obstructed defecation.

    Science.gov (United States)

    Dietz, H P; Beer-Gabel, M

    2012-07-01

    Recent developments in diagnostic imaging have made gynecologists, colorectal surgeons and gastroenterologists realize as never before that they share a common interest in anorectal and pelvic floor dysfunction. While we often may be using different words to describe the same phenomenon (e.g. anismus/vaginismus) or attributing different meanings to the same words (e.g. rectocele), we look after patients with problems that transcend the borders of our respective specialties. Like no other diagnostic modality, imaging helps us understand each other and provides new insights into conditions we all need to learn to investigate better in order to improve clinical management. In this review we attempt to show what modern ultrasound imaging can contribute to the diagnostic work-up of patients with posterior vaginal wall prolapse, obstructed defecation and rectal intussusception/prolapse. In summary, it is evident that translabial/perineal ultrasound can serve as a first-line diagnostic tool in women with such complaints, replacing defecation proctography and MR proctography in a large proportion of female patients. This is advantageous for the women themselves because ultrasound is much better tolerated, as well as for healthcare systems since sonographic imaging is much less expensive. However, there is a substantial need for education, which currently remains unmet. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  11. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  12. Automatic Ultrasound Scanning

    DEFF Research Database (Denmark)

    Moshavegh, Ramin

    on the user adjustments on the scanner interface to optimize the scan settings. This explains the huge interest in the subject of this PhD project entitled “AUTOMATIC ULTRASOUND SCANNING”. The key goals of the project have been to develop automated techniques to minimize the unnecessary settings...... on the scanners, and to improve the computer-aided diagnosis (CAD) in ultrasound by introducing new quantitative measures. Thus, four major issues concerning automation of the medical ultrasound are addressed in this PhD project. They touch upon gain adjustments in ultrasound, automatic synthetic aperture image...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends the sound waves into ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... region of the prostate. A biopsy will add time to the procedure. If a Doppler ultrasound study ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pictures of a man’s prostate gland and to help diagnose symptoms such as difficulty urinating or an ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... questions or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  8. Forward tracking detectors

    Indian Academy of Sciences (India)

    Abstract. Forward tracking is an essential part of a detector at the international linear collider (ILC). The requirements for forward tracking are explained and the proposed solutions in the detector concepts are shown.

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on ...

  11. Ultrasound stethoscopy

    NARCIS (Netherlands)

    E.C. Vourvouri (Eleni)

    2002-01-01

    textabstractIn this thesis we repmi the many evaluation studies with the hand-held ultrasound device in the assessment of different cardiac pathologies and in different clinical settings. The reason for using the tetm "ultrasound stethoscopy" is that these devices are augmenting our

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  13. SU-G-JeP3-08: Robotic System for Ultrasound Tracking in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlemann, I [University of Luebeck, Luebeck (Germany); Graduate School for Computing in Medicine and Life Sciences, University of Luebeck (Germany); Jauer, P; Schweikard, A; Ernst, F [University of Luebeck, Luebeck (Germany)

    2016-06-15

    Purpose: For safe and accurate real-time tracking of tumors for IGRT using 4D ultrasound, it is necessary to make use of novel, high-end force-sensitive lightweight robots designed for human-machine interaction. Such a robot will be integrated into an existing robotized ultrasound system for non-invasive 4D live tracking, using a newly developed real-time control and communication framework. Methods: The new KUKA LWR iiwa robot is used for robotized ultrasound real-time tumor tracking. Besides more precise probe contact pressure detection, this robot provides an additional 7th link, enhancing the dexterity of the kinematic and the mounted transducer. Several integrated, certified safety features create a safe environment for the patients during treatment. However, to remotely control the robot for the ultrasound application, a real-time control and communication framework has to be developed. Based on a client/server concept, client-side control commands are received and processed by a central server unit and are implemented by a client module running directly on the robot’s controller. Several special functionalities for robotized ultrasound applications are integrated and the robot can now be used for real-time control of the image quality by adjusting the transducer position, and contact pressure. The framework was evaluated looking at overall real-time capability for communication and processing of three different standard commands. Results: Due to inherent, certified safety modules, the new robot ensures a safe environment for patients during tumor tracking. Furthermore, the developed framework shows overall real-time capability with a maximum average latency of 3.6 ms (Minimum 2.5 ms; 5000 trials). Conclusion: The novel KUKA LBR iiwa robot will advance the current robotized ultrasound tracking system with important features. With the developed framework, it is now possible to remotely control this robot and use it for robotized ultrasound tracking

  14. SU-G-JeP3-08: Robotic System for Ultrasound Tracking in Radiation Therapy

    International Nuclear Information System (INIS)

    Kuhlemann, I; Jauer, P; Schweikard, A; Ernst, F

    2016-01-01

    Purpose: For safe and accurate real-time tracking of tumors for IGRT using 4D ultrasound, it is necessary to make use of novel, high-end force-sensitive lightweight robots designed for human-machine interaction. Such a robot will be integrated into an existing robotized ultrasound system for non-invasive 4D live tracking, using a newly developed real-time control and communication framework. Methods: The new KUKA LWR iiwa robot is used for robotized ultrasound real-time tumor tracking. Besides more precise probe contact pressure detection, this robot provides an additional 7th link, enhancing the dexterity of the kinematic and the mounted transducer. Several integrated, certified safety features create a safe environment for the patients during treatment. However, to remotely control the robot for the ultrasound application, a real-time control and communication framework has to be developed. Based on a client/server concept, client-side control commands are received and processed by a central server unit and are implemented by a client module running directly on the robot’s controller. Several special functionalities for robotized ultrasound applications are integrated and the robot can now be used for real-time control of the image quality by adjusting the transducer position, and contact pressure. The framework was evaluated looking at overall real-time capability for communication and processing of three different standard commands. Results: Due to inherent, certified safety modules, the new robot ensures a safe environment for patients during tumor tracking. Furthermore, the developed framework shows overall real-time capability with a maximum average latency of 3.6 ms (Minimum 2.5 ms; 5000 trials). Conclusion: The novel KUKA LBR iiwa robot will advance the current robotized ultrasound tracking system with important features. With the developed framework, it is now possible to remotely control this robot and use it for robotized ultrasound tracking

  15. Forward Jets and Forward-Central Jets at CMS

    CERN Document Server

    INSPIRE-00176215

    2012-01-01

    We report on cross section measurements for inclusive forward jet production and for the simultaneous production of a forward and a central jet in sqrt{s} = 7 TeV pp-collisions. Data collected in 2010, corresponding to an integrated luminosity of 3.14 pb^{-1}, is used for the measurements. Jets in the transverse momentum range pT = 35 - 140 GeV/c are reconstructed with the anti-kT (R = 0.5) algorithm. The extended coverage of large pseudo-rapidities is provided by the Hadronic Forward calorimeter (3.2 < \\eta < 4.7), while central jets are limited to \\eta < 2.8, covered by the main detector components. The two differential cross sections are presented as a function of the jet transverse momentum. Comparisons to next-to-leading order perturbative calculations, and predictions from event generators based on different parton showering mechanisms (PYTHIA and HERWIG) and parton dynamics (CASCADE) are shown.

  16. A NEW LOOK AT THE TRADE VOLUME EFFECTS OF REAL EXCHANGE RATE RISK

    OpenAIRE

    Wang, Kai-Li; Barrett, Christopher B.

    2002-01-01

    This paper takes a new empirical look at the longstanding question of the effect of exchange rate volatility on international trade flows by studying the case of Taiwan's exports to the United States from 1989-1998. In particular, we employ sectoral level, monthly data and a multivariate GARCH-M estimator with corrections for leptokurtic errors that is consistent with the core hypothesis that traders' forward contracting behavior might be affected by exchange rate risk. We find that real exch...

  17. Ultrasound skin tightening.

    Science.gov (United States)

    Minkis, Kira; Alam, Murad

    2014-01-01

    Ultrasound skin tightening is a noninvasive, nonablative method that allows for energy deposition into the deep dermal and subcutaneous tissue while avoiding epidermal heating. Ultrasound coagulation is confined to arrays of 1-mm(3) zones that include the superficial musculoaponeurotic system and connective tissue. This technology gained approval from the Food and Drug Administration as the first energy-based skin "lifting" device, specifically for lifting lax tissue on the neck, submentum, and eyebrows. Ultrasound has the unique advantage of direct visualization of treated structures during treatment. Ultrasound is a safe and efficacious treatment for mild skin tightening and lifting. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Ultrasound guided supraclavicular block.

    LENUS (Irish Health Repository)

    Hanumanthaiah, Deepak

    2013-09-01

    Ultrasound guided regional anaesthesia is becoming increasingly popular. The supraclavicular block has been transformed by ultrasound guidance into a potentially safe superficial block. We reviewed the techniques of performing supraclavicular block with special focus on ultrasound guidance.

  19. Percutaneous retrieval of an intracardiac central venous port fragment using snare with triple loops

    Directory of Open Access Journals (Sweden)

    Mehdi Ghaderian

    2015-01-01

    Full Text Available Peripherally inserted venous ports fracture with embolization in patients who received chemotherapy is a serious and rare complication, and few cases have been reported in children. We report a successful endovascular technique using a snare for retrieving broken peripherally inserted venous ports in a child for chemotherapy. Catheter fragments may cause complications such as cardiac perforation, arrhythmias, sepsis, and pulmonary embolism. A 12-year-old female received chemotherapy for acute lymphocytic leukemia through a central venous port implanted into her right subclavian area. The patient completed chemotherapy without complications 6 months ago. Venous port was accidentally fractured during its removal. Chest radiographs of the patient revealed intracardiac catheter fragment extending from the right subclavian to the right atrium (RA and looping in the RA. The procedure was performed under ketamine and midazolam anesthesia and fluoroscopic guidance using a percutaneous femoral vein approach. A snare with triple loops (10 mm in diameter was used to successfully retrieve the catheter fragments without any complication. Percutaneous transcatheter retrieval of catheter fragments is occasionally extremely useful and should be considered by interventional cardiologists for retrieving migrated catheters and can be chosen before resorting to surgery, which has potential risks related to thoracotomy, cardiopulmonary bypass, and general anesthesia.

  20. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  1. Deep convolutional neural networks for estimating porous material parameters with ultrasound tomography

    Science.gov (United States)

    Lähivaara, Timo; Kärkkäinen, Leo; Huttunen, Janne M. J.; Hesthaven, Jan S.

    2018-02-01

    We study the feasibility of data based machine learning applied to ultrasound tomography to estimate water-saturated porous material parameters. In this work, the data to train the neural networks is simulated by solving wave propagation in coupled poroviscoelastic-viscoelastic-acoustic media. As the forward model, we consider a high-order discontinuous Galerkin method while deep convolutional neural networks are used to solve the parameter estimation problem. In the numerical experiment, we estimate the material porosity and tortuosity while the remaining parameters which are of less interest are successfully marginalized in the neural networks-based inversion. Computational examples confirms the feasibility and accuracy of this approach.

  2. Ultrasound diagnostics of thyroid diseases

    International Nuclear Information System (INIS)

    Kharchenko, Vladimir P.; Kotlyarov, Peter M.; Mogutov, Mikhail S.; Sencha, Alexander N.; Patrunov, Yury N.; Belyaev, Denis V.; Alexandrov, Yury K.

    2010-01-01

    This book is based on the authors' extensive practical experience in the use of modern ultrasound, and other radiological methods, in the diagnosis of thyroid diseases. The authors have analyzed more than 100,000 ultrasound examinations performed between 1995 and 2008 in patients with thyroid and parathyroid disease, as well as many thousands of diagnostic and therapeutic ultrasound-guided minimally invasive procedures. The opening chapters include discussion of current ultrasound techniques, pitfalls, and the specifics of ultrasound examination of the thyroid in children. Detailed attention is then devoted to findings in the normal thyroid and in the presence of diffuse and focal changes. Further chapters focus on such topics as ultrasound examination after thyroid surgery and ultrasound diagnosis of parathyroid disease, recurrent goiter, and neck masses. Ultrasound-guided minimally invasive techniques, such as fine-needle aspiration biopsy, percutaneous laser ablation, and ethanol and glucocorticoid injections, are considered in depth. This up-to-date and richly illustrated book will interest and assist specialists in ultrasound diagnostics, radiologists, endocrinologists, and neck surgeons. (orig.)

  3. An ultrasound system for simultaneous ultrasound hyperthermia and photon beam irradiation

    International Nuclear Information System (INIS)

    Straube, William L.; Moros, Eduardo G.; Low, Daniel A.; Klein, Eric E.; Willcut, Virgil M.; Myerson, Robert J.

    1996-01-01

    Purpose: An existing ultrasound system has been adapted for simultaneous use with external photon beam irradiation. The system is being used to investigate the potential for increased biological benefit of simultaneously combined hyperthermia and external beam irradiation with currently achievable temperature distributions. Methods and Materials: An existing clinical ultrasound system has been modified for simultaneous operation with a 60 Co teletherapy machine. The generator, thermometry system, computer, and applicators are located inside the treatment room, while the monitor and system control are located at the control console. Two approaches have been used clinically to combine the two modalities. In the first approach, an en-face setup is used in which the ultrasound beam and the photon beam travel through the same window of entry to the tumor. This is achieved by a reflecting system designed to deflect the ultrasound to the tumor while positioning the ultrasound transducer outside the radiation beam. The reflecting system consists of water and water-equivalent materials except for a 1 mm sheet of polished brass that is used as the reflector. The relative pressure fields were measured in water at the same distance from the ultrasound source using a scanning hydrophone with and without the reflector at the two operating frequencies of the device (1.0 and 3.4 MHz) for two applicators. Radiation dosimetry measurements were performed to determine the relationship between 60 Co irradiation through the reflector and absorbed dose. In the second approach the ultrasound and the radiation beam travel into the tumor from different windows of entry such that the radiation beam passes through no portion of the water bolus prior to entering the patient. We have termed this approach the orthogonal approach. For both approaches, the radiation fraction is given in the middle of an uninterrupted 60-min hyperthermia treatment. Results: The system modifications did not impair

  4. Prostate Ultrasound

    Science.gov (United States)

    ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses ...

  6. Trans-abdominal ultrasound evaluation of high-intensity focused ultrasound treatment of uterine leiomyoma

    International Nuclear Information System (INIS)

    Miao Wei; Huang Jin; Wang Junhua; Wang Yuling

    2010-01-01

    Objective: To determine the value of dynamic trans-abdominal ultrasound after high-intensity focused ultrasound (HIFU) treatment of uterine leiomyomas. Methods: The trans-abdominal ultrasound images of 63 patients before and after HIFU treatment of uterine leiomyomas were compared. Results: The volume and blood flow of leiomyomas were reduced after the HIFU treatment. Conclusion: Trans-abdominal ultrasound is a valuable method for evaluating the results of HIFU treatment of uterine leiomyomas. (authors)

  7. Long Maturity Forward Rates

    DEFF Research Database (Denmark)

    Christiansen, Charlotte

    2001-01-01

    The paper aims to improve the knowledge of the empirical properties of the long maturity region of the forward rate curve. Firstly, the theoretical negative correlation between the slope at the long end of the forward rate curve and the term structure variance is recovered empirically and found...... to be statistically significant. Secondly, the expectations hypothesis is analyzed for the long maturity region of the forward rate curve using "forward rate" regressions. The expectations hypothesis is numerically close to being accepted but is statistically rejected. The findings provide mixed support...... for the affine term structure model....

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... and treat medical conditions. Conventional ultrasound displays the images in thin, flat sections of the body. Advancements in ultrasound technology include three-dimensional (3- ...

  9. Envisioning New Technologies in Teacher Practice: Moving Forward, Circling Back Using a Teacher Action Research Approach. New Literacies and Digital Epistemologies. Volume 47

    Science.gov (United States)

    Strong-Wilson, Teresa, Ed.

    2012-01-01

    How do classroom teachers envision new technologies within their practice? In the conversation on incorporating new technologies into classrooms, teachers are often sidelined. "Envisioning New Technologies in Teacher Practice" looks at the complex ways in which teachers move forward to embrace change as well as how they circle back, continually…

  10. Wind energy in 1996: Looking forward, looking back

    Energy Technology Data Exchange (ETDEWEB)

    Swisher, R.

    1996-12-31

    Opinions on the world market for wind power are presented in this paper. A brief review of progress in wind energy is given. The impact of world market forces and restructuring of the electric industry in the U.S. on the wind energy market are discussed. An outline of the American Wind Energy Association`s Renewables Portfolio Standard is presented. Legislative activities in wind energy are also reviewed.

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Conventional ultrasound displays the images in thin, ...

  12. Effect of driving experience on anticipatory look-ahead fixations in real curve driving.

    Science.gov (United States)

    Lehtonen, Esko; Lappi, Otto; Koirikivi, Iivo; Summala, Heikki

    2014-09-01

    Anticipatory skills are a potential factor for novice drivers' curve accidents. Behavioural data show that steering and speed regulation are affected by forward planning of the trajectory. When approaching a curve, the relevant visual information for online steering control and for planning is located at different eccentricities, creating a need to disengage the gaze from the guidance of steering to anticipatory look-ahead fixations over curves. With experience, peripheral vision can be increasingly used in the visual guidance of steering. This could leave experienced drivers more gaze time to invest on look-ahead fixations over curves, facilitating the trajectory planning. Eighteen drivers (nine novices, nine experienced) drove an instrumented vehicle on a rural road four times in both directions. Their eye movements were analyzed in six curves. The trajectory of the car was modelled and divided to approach, entry and exit phases. Experienced drivers spent less time on the road-ahead and more time on the look-ahead fixations over the curves. Look-ahead fixations were also more common in the approach than in the entry phase of the curve. The results suggest that with experience drivers allocate greater part of their visual attention to trajectory planning. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. The Indian ultrasound paradox

    OpenAIRE

    Akbulut-Yuksel, Mevlude; Rosenblum, Daniel

    2012-01-01

    The liberalization of the Indian economy in the 1990s made prenatal ultrasound technology affordable and available to a large fraction of the population. As a result, ultrasound use amongst pregnant women rose dramatically in many parts of India. This paper provides evidence on the consequences of the expansion of prenatal ultrasound use on sex-selection. We exploit state-by-cohort variation in ultrasound use in India as a unique quasi-experiment. We find that sex-selective abortion of female...

  14. Point of Care Ultrasound

    DEFF Research Database (Denmark)

    Dietrich, Christoph F; Goudie, Adrian; Chiorean, Liliana

    2017-01-01

    Over the last decade, the use of portable ultrasound scanners has enhanced the concept of point of care ultrasound (PoC-US), namely, "ultrasound performed at the bedside and interpreted directly by the treating clinician." PoC-US is not a replacement for comprehensive ultrasound, but rather allows...... and critical care medicine, cardiology, anesthesiology, rheumatology, obstetrics, neonatology, gynecology, gastroenterology and many other applications. In the future, PoC-US will be more diverse than ever and be included in medical student training....

  15. Action Prediction Allows Hypothesis Testing via Internal Forward Models at 6 Months of Age

    Directory of Open Access Journals (Sweden)

    Gustaf Gredebäck

    2018-03-01

    Full Text Available We propose that action prediction provides a cornerstone in a learning process known as internal forward models. According to this suggestion infants’ predictions (looking to the mouth of someone moving a spoon upward will moments later be validated or proven false (spoon was in fact directed toward a bowl, information that is directly perceived as the distance between the predicted and actual goal. Using an individual difference approach we demonstrate that action prediction correlates with the tendency to react with surprise when social interactions are not acted out as expected (action evaluation. This association is demonstrated across tasks and in a large sample (n = 118 at 6 months of age. These results provide the first indication that infants might rely on internal forward models to structure their social world. Additional analysis, consistent with prior work and assumptions from embodied cognition, demonstrates that the latency of infants’ action predictions correlate with the infant’s own manual proficiency.

  16. [Ultrasound findings in rhabdomyolysis].

    Science.gov (United States)

    Carrillo-Esper, Raúl; Galván-Talamantes, Yazmin; Meza-Ayala, Cynthia Margarita; Cruz-Santana, Julio Alberto; Bonilla-Reséndiz, Luis Ignacio

    Rhabdomyolysis is defined as skeletal muscle necrosis. Ultrasound assessment has recently become a useful tool for the diagnosis and monitoring of muscle diseases, including rhabdomyolysis. A case is presented on the ultrasound findings in a patient with rhabdomyolysis. To highlight the importance of ultrasound as an essential part in the diagnosis in rhabdomyolysis, to describe the ultrasound findings, and review the literature. A 30 year-old with post-traumatic rhabdomyolysis of both thighs. Ultrasound was performed using a Philips Sparq model with a high-frequency linear transducer (5-10MHz), in low-dimensional scanning mode (2D), in longitudinal and transverse sections at the level of both thighs. The images obtained showed disorganisation of the orientation of the muscle fibres, ground glass image, thickening of the muscular fascia, and the presence of anechoic areas. Ultrasound is a useful tool in the evaluation of rhabdomyolysis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  18. Medical Ultrasound Imaging.

    Science.gov (United States)

    Hughes, Stephen

    2001-01-01

    Explains the basic principles of ultrasound using everyday physics. Topics include the generation of ultrasound, basic interactions with material, and the measurement of blood flow using the Doppler effect. (Author/MM)

  19. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  20. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... used to screen for brain conditions associated with prematurity, such as bleeding or brain tissue damage as ... or crying child will slow the examination process. Large patients are more difficult to image by ultrasound, ...

  1. Quantitative Ultrasound Measurements at the Heel

    DEFF Research Database (Denmark)

    Daugschies, M.; Brixen, K.; Hermann, P.

    2015-01-01

    Calcaneal quantitative ultrasound can be used to predict osteoporotic fracture risk, but its ability to monitor therapy is unclear possibly because of its limited precision. We developed a quantitative ultrasound device (foot ultrasound scanner) that measures the speed of sound at the heel...... with the foot ultrasound scanner reduced precision errors by half (p quantitative ultrasound measurements is feasible. (E-mail: m.daugschies@rad.uni-kiel.de) (C) 2015 World Federation for Ultrasound in Medicine & Biology....

  2. Enhancement or Reduction of Sonochemical Activity of Pulsed Ultrasound Compared to Continuous Ultrasound at 20 kHz?

    Directory of Open Access Journals (Sweden)

    Yujing Sun

    2013-04-01

    Full Text Available Little is known about the efficacy of pulsed ultrasound compared with continuous ultrasound. Previous studies on the efficacy of pulsed ultrasound were not systematic and gave different results. In this study, the effects of pulse length, pulse interval, pulse length × pulse intervals, and treatment time on sonochemical activity were investigated using a simple oxidation of iodide method and a comparison of the efficacy of pulsed ultrasound and continuous ultrasound is made. The results showed that the main factor in the efficacy of pulsed ultrasound was pulse length when pulse length varied from 0.1 to 1 s. However, the main factors were pulse length, the pulse length × pulse interval, and pulse interval when pulse length varied from 1 to 9 s. Pulsed ultrasound had no effect when the pulse length was 0.1 s; however, the sonochemical activity of pulsed ultrasound decreased compared to continuous ultrasound as the pulse length varied from 0.1 to 1 s. The sonochemical activity of pulsed ultrasound either increased or decreased compared to continuous ultrasound when pulse length varied from 1 to 9 s, but the increase or decrease had no clear trend. The sonochemical activity was constant at Ton/Toff = 2 s/2 s and slightly decreased at Ton/Toff = 3 s/2 s with time, whereas the sonochemical activity of continuous ultrasound significantly decreased with time. Enhancement or reduction of sonochemical activity of pulsed ultrasound compared to continuous ultrasound depended on the pulse length and pulse interval.

  3. Model-Based Reconstructive Elasticity Imaging Using Ultrasound

    Directory of Open Access Journals (Sweden)

    Salavat R. Aglyamov

    2007-01-01

    Full Text Available Elasticity imaging is a reconstructive imaging technique where tissue motion in response to mechanical excitation is measured using modern imaging systems, and the estimated displacements are then used to reconstruct the spatial distribution of Young's modulus. Here we present an ultrasound elasticity imaging method that utilizes the model-based technique for Young's modulus reconstruction. Based on the geometry of the imaged object, only one axial component of the strain tensor is used. The numerical implementation of the method is highly efficient because the reconstruction is based on an analytic solution of the forward elastic problem. The model-based approach is illustrated using two potential clinical applications: differentiation of liver hemangioma and staging of deep venous thrombosis. Overall, these studies demonstrate that model-based reconstructive elasticity imaging can be used in applications where the geometry of the object and the surrounding tissue is somewhat known and certain assumptions about the pathology can be made.

  4. The Positive Outcome of MRI-Guided Vacuum Assisted Core Needle Breast Biopsies Is Not Influenced by a Prior Negative Targeted Second-Look Ultrasound.

    Science.gov (United States)

    Ferré, Romuald; AlSharif, Shaza; Aldis, Ann; Mesurolle, Benoît

    2017-11-01

    The study sought to investigate the outcome of breast magnetic resonance-guided biopsies as a function of the indication for magnetic resonance imaging (MRI), the MRI features of the lesions, and the performance or not of a targeted second-look ultrasound (SLUS) prior breast MRI-guided biopsy. We identified 158 women with MRI-detected breast lesions scheduled for MRI-guided biopsy (2007-2013). Patient demographics, performance of targeted SLUS, imaging characteristics, and subsequent pathology results were reviewed. Three biopsies were deferred, and 155 lesions were biopsied under MRI guidance (155 women; median age 55.14 years; range 27-80 years). Ninety-eight women underwent a SLUS prior to the MRI-guided biopsy (63%). Of the 155 biopsied lesions, 23 (15%) were malignant, 106 (68%) were benign, and 26 (17%) were high risk. Four of 15 surgically excised high-risk lesions were upgraded to malignancy (27%). Most of the biopsied lesions corresponded to non-mass-like enhancement (81%, 126 of 155) and most of the biopsies (52%, 81 of 155) were performed in a screening context. No demographic or MRI features were associated with malignancy. No differences were noted between the 2 subgroups (prior SLUS vs no prior SLUS) except for the presence of a synchronous carcinoma associated with a likelihood of targeted SLUS before MRI-guided biopsy (P = .001). A negative SLUS does not influence the pathology outcome of a suspicious lesion biopsied under MR guidance. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... may produce minimal discomfort. If a Doppler ultrasound study is performed, you may actually hear pulse-like sounds that change in pitch as the blood flow is monitored and measured. Most ultrasound examinations ...

  7. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cary, Theodore W.; Sultan, Laith R.; Sehgal, Chandra M., E-mail: sehgalc@uphs.upenn.edu [Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Reamer, Courtney B.; Mohler, Emile R. [Department of Medicine, Division of Cardiovascular Medicine, Section of Vascular Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

    2014-02-15

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.

  8. Basics of biomedical ultrasound for engineers

    CERN Document Server

    Azhari, Haim

    2010-01-01

    "Basics of Biomedical Ultrasound for Engineers is a structured textbook for university engineering courses in biomedical ultrasound and for researchers in the field. This book offers a tool for building a solid understanding of biomedical ultrasound, and leads the novice through the field in a step-by-step manner. The book begins with the most basic definitions of waves, proceeds to ultrasounds in fluids, and then delves into solid ultrasounds, the most complicated kind of ultrasound. It encompasses a wide range of topics within biomedical ultrasound, from conceptual definitions of waves to the intricacies of focusing devices, transducers, and acoustic fields"--Provided by publisher.

  9. Forward, Forward Option and No Hedging Which One is the Best for Managing Currency Risk?

    Directory of Open Access Journals (Sweden)

    Riko Hendrawan

    2017-07-01

    Full Text Available Bank Indonesia Regulation No.18/18/PBI/2016 concerning foreign exchange transactions against rupiah between banks and domestic parties, indicates that the importance of hedging for business actors in Indonesia. Based on the data of the rupiah exchange rate movement against the dollar from January 2006 to December 2016 shows that the fluctuation of the rupiah against the US dollar tends to weaken, although at some point the observation shows the strengthening of the rupiah against the US dollar. The purpose of this research is to assess impact of Forward, Forward Option and No Hedging Strategy for managing currency exposure between IDR to USD. Using data from January 2006–December 2016 taken from website of Bank Indonesia and Federal Reserve. Total 396 simulations,consists of 132 using Forward simulations, 132 using Forward Option simulations and 132 using No Hedging simulations. Findings from this research show that Forward Option was has no positive contribution in managing currency exposure, No Hedging Strategy has 36,36 percent positive contribution and forward contract has 72,73 percent positive contribution in managing currency exposure. Its means Forward Contract was better than Forward Option and No Hedging Strategies in managing currency exposure.

  10. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... legs, neck and/or brain (in infants and children) or within various body organs such as the ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... color picture. It can also convert blood flow information into a distinctive sound that can be heard ...

  16. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... care physician, or to the physician or other healthcare provider who requested the exam. Usually, the referring ...

  17. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... need to be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can ... ultrasound procedure View full size with caption Pediatric Content Some imaging tests and treatments have special pediatric ...

  19. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... procedure? Ultrasound examinations can help to diagnose a variety of conditions and to assess organ damage following ... the Ultrasound-Guided Breast Biopsy page . diagnose a variety of heart conditions, including valve problems and congestive ...

  20. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Angioplasty and ...

  1. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  2. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... more extensive exams may take up to an hour. When the examination is complete, you may be ...

  3. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes ...

  4. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound ... computer or television monitor. The image is created based on the amplitude (loudness), frequency (pitch) and time ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... in infections With knowledge about the speed and volume of blood flow gained from a Doppler ultrasound ... the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. top of page ...

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... sonography is performed using the same transducer. Rarely, young children may need to be sedated in order ...

  9. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  10. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... American College of Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise ...

  11. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... about this beforehand and be made aware of food and drink restrictions that may be needed prior ...

  12. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... flat sections of the body. Advancements in ultrasound technology include three-dimensional (3-D) ultrasound that formats ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... 3-D) ultrasound that formats the sound wave data into 3-D images. A Doppler ultrasound study ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  15. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... testing. image the breasts and guide biopsy of breast cancer ( see the Ultrasound-Guided Breast Biopsy page . diagnose ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ...

  16. Forward tracking detectors

    Indian Academy of Sciences (India)

    At the ILC many of the most important physics reactions are central, so that the forward region, which is suppressed by the cos θ phase space factor often is a bit neglected. However, many processes at the ILC are peaked in the forward region like Bhabha scattering or W-pair production [1]. Fermion pair production has its.

  17. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    To demonstrate the feasibility of CT and B-mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non-thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position-sensing arm and an active six degree-of-freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2-4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre-clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre-clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non-enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre-clinical models may be translated to large

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  19. Children's (Pediatric) Abdominal Ultrasound Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of the ... abdomen using ultrasound. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  20. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  1. Evaluation of aspirin therapy on intracardiac thrombi using indium-111-oxine platelet scintigraphy, two-dimentional echocardiography and left ventriculography

    International Nuclear Information System (INIS)

    Shibuya, Masanori; Irino, Tadayoshi; Yoshioka, Toshiharu; Sugimoto, Tsuyoshi; Tsuji, Kazuo; Naka, Masashi; Arai, Hidekazu.

    1984-01-01

    Left ventriculography (LVG), two-dimensional echocardiography (2-DE) and indium-111-oxine platelet scintigraphy were performed in five patients with intracardiac thrombi. Thrombi were visible in 7 sites (5 in the ventricle and 2 in the atrium) by platelet scintigraphy, in 4 sites (3 in the ventricle and 1 in the atrium) by 2-DE, and in 4 sites (4 in the ventricle) by LVG. When aspirin was administered to the patients, platelet scintigraphy had become negative for thrombi in 5 sites and false-negative for them in 2 sites. However, thrombi were detected in 6 sites after the withdrawal of aspirin. On the other hand, thrombi were detected in 4 sites by 2-DE, irrespective of the administration of aspirin. Indium-111-oxine platelet scintigraphy has proved to not only have higher sensitivity for detecting thrombi but also to be capable of observing the coagulation status of platelets on the thrombi. It is therefore considered very helpful in assessing anticoagulation therapy. (Namekawa, K)

  2. Perceptions of Healthy-Looking and Sexy-Looking Brow Thickness.

    Science.gov (United States)

    Hwang, Kun; Kim, Hun

    2018-06-01

    This study aims to determine which brow thickness levels were considered ideal, healthy-looking, young-looking, and sexy-looking by Koreans.The 163 women and 38 men who visited a brow bar were asked to view illustrations of 4 brow thickness levels defined in terms of the percentage of the eye width at the lateral canthus: very thin (VTn-1/6) (16% of eye width), thin (Tn-1/5) (20%), medium (Med-1/4) (25%), and thick (Tk-1/3) (33%) and to choose which they thought were ideal, young-looking, healthy-looking, and sexy-looking.Med-1/4 (61.2%) was the brow thickness most often considered to be ideal, followed by Tk-1/3 (17.4%) and Tn-1/5 (15.9%). VTn-1/6 was the least preferred (5.5%). Med-1/4 was the most preferred ideal thickness among both sexes. Tk-1/3 (40.8%) was the thickness most often considered to be young-looking, followed by Med-1/4 (35.3%) and Tn-1/5 (18.4%). VTn-1/6 was the least preferred (5.5%). Tk-1/3 was the most preferred young-looking thickness among both sexes. Tk-1/3 (48.8%) was the thickness most often considered to be healthy-looking, followed by Med-1/4 (30.8%) and Tn-1/5 (11.9%). VTn-1/6 was the least preferred (8.5%). Tk-1/3 was the most preferred healthy-looking thickness by women (52.2%), whereas Med-1/4 was the most common choice among men (39.5%). Tn-1/5 (40.8%) was the thickness most often considered to be sexy-looking, followed by VTn-1/6 (25.9%) and Med-1/4 (21.4%). Tk-1/3 was the least preferred (11.9%). Tn-1/5 was the most preferred sexy-looking thickness among both sexes.The results may be used as guidelines for patient or customer preferences in facial rejuvenation operations, brow esthetics, or tattooing.

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... child's abdominal ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of the ... abdomen using ultrasound. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) Ultrasound - Abdomen Children’s (pediatric) ultrasound imaging of ... 30 minutes. top of page What will my child experience during and after the procedure? Ultrasound examinations ...

  6. Research interface on a programmable ultrasound scanner.

    Science.gov (United States)

    Shamdasani, Vijay; Bae, Unmin; Sikdar, Siddhartha; Yoo, Yang Mo; Karadayi, Kerem; Managuli, Ravi; Kim, Yongmin

    2008-07-01

    Commercial ultrasound machines in the past did not provide the ultrasound researchers access to raw ultrasound data. Lack of this ability has impeded evaluation and clinical testing of novel ultrasound algorithms and applications. Recently, we developed a flexible ultrasound back-end where all the processing for the conventional ultrasound modes, such as B, M, color flow and spectral Doppler, was performed in software. The back-end has been incorporated into a commercial ultrasound machine, the Hitachi HiVision 5500. The goal of this work is to develop an ultrasound research interface on the back-end for acquiring raw ultrasound data from the machine. The research interface has been designed as a software module on the ultrasound back-end. To increase the amount of raw ultrasound data that can be spooled in the limited memory available on the back-end, we have developed a method that can losslessly compress the ultrasound data in real time. The raw ultrasound data could be obtained in any conventional ultrasound mode, including duplex and triplex modes. Furthermore, use of the research interface does not decrease the frame rate or otherwise affect the clinical usability of the machine. The lossless compression of the ultrasound data in real time can increase the amount of data spooled by approximately 2.3 times, thus allowing more than 6s of raw ultrasound data to be acquired in all the modes. The interface has been used not only for early testing of new ideas with in vitro data from phantoms, but also for acquiring in vivo data for fine-tuning ultrasound applications and conducting clinical studies. We present several examples of how newer ultrasound applications, such as elastography, vibration imaging and 3D imaging, have benefited from this research interface. Since the research interface is entirely implemented in software, it can be deployed on existing HiVision 5500 ultrasound machines and may be easily upgraded in the future. The developed research

  7. Looking Back and Looking Forward: Reprising the Promise and Predicting the Future of Formation Flying and Spaceborne GPS Navigation Systems

    Science.gov (United States)

    Bauer, Frank H.; Dennehy, Neil

    2015-01-01

    A retrospective consideration of two 15-year old Guidance, Navigation and Control (GN&C) technology 'vision' predictions will be the focus of this paper. A look back analysis and critique of these late 1990s technology roadmaps out-lining the future vision, for two then nascent, but rapidly emerging, GN&C technologies will be performed. Specifically, these two GN&C technologies were: 1) multi-spacecraft formation flying and 2) the spaceborne use and exploitation of global positioning system (GPS) signals to enable formation flying. This paper reprises the promise of formation flying and spaceborne GPS as depicted in the cited 1999 and 1998 papers. It will discuss what happened to cause that promise to be mostly unfulfilled and the reasons why the envisioned formation flying dream has yet to become a reality. The recent technology trends over the past few years will then be identified and a renewed government interest in spacecraft formation flying/cluster flight will be highlighted. The authors will conclude with a reality-tempered perspective, 15 years after the initial technology roadmaps were published, predicting a promising future of spacecraft formation flying technology development over the next decade.

  8. Power forward curves: a managerial perspective

    International Nuclear Information System (INIS)

    Nagarajan, Shankar

    1999-01-01

    This chapter concentrates on managerial application of power forward curves, and examines the determinants of electricity prices such as transmission constraints, its inability to be stored in a conventional way, its seasonality and weather dependence, the generation stack, and the swing risk. The electricity forward curve, classical arbitrage, constructing a forward curve, volatilities, and electricity forward curve models such as the jump-diffusion model, the mean-reverting heteroscedastic volatility model, and an econometric model of forward prices are examined. A managerial perspective of the applications of the forward curve is presented covering plant valuation, capital budgeting, performance measurement, product pricing and structuring, asset optimisation, valuation of transmission options, and risk management

  9. How to learn and to perform endoscopic ultrasound and endobronchial ultrasound for lung cancer staging

    DEFF Research Database (Denmark)

    Konge, Lars; Colella, Sara; Vilmann, Peter

    2015-01-01

    The learning of transesophageal ultrasound guided fine needle aspiration (FNA) (endoscopic ultrasound-FNA), and endobronchial ultrasound guided transbronchial needle aspiration (endosonography) should be based on the following steps: Acquiring theoretical knowledge, training on simulators, and su...

  10. Point-of-care Ultrasound for the Diagnosis of a Gluteal Abscess

    Directory of Open Access Journals (Sweden)

    Kevin Roy

    2018-01-01

    Full Text Available History of present illness: A 57-year-old male with a history of intravenous drug use presented to the emergency department with four days of progressively worsening pain and swelling to his left buttock after injecting heroin subcutaneously (i.e., “skin popping”. Labs were significant for a white blood cell count (WBC of 26,700/mm3. Using the high frequency, linear probe, a point-of-care ultrasound (POCUS was performed and revealed a large soft tissue abscess. Significant findings: POCUS reveals a large, hypoechoic soft tissue abscess with debris and tracks extending to the bottom of the image. Furthermore, when compressed, movement of the abscess contents is appreciated. There is also superficial cobble-stoning consistent with overlying cellulitis and soft tissue edema. Discussion: In the United States, there are over 14 million outpatient visits per year related to soft tissue infections, with nearly one-third being seen in the emergency department.1,2 22%-65% of intravenous drug users experience abscesses and cellulitis.3 Soft tissue abscesses are commonly encountered in the emergency department and the diagnosis is often made by history and physical exam.5 However, imaging modalities are more accurate than physical exam alone. When comparing ultrasound to physical exam in the diagnosis of soft tissue abscesses, one study suggests that ultrasound has a sensitivity and specificity of 96% and 87%, respectively. The sensitivity and specificity of the physical exam is 84% and 60%, respectively.4 Another study comparing computed tomography (CT to ultrasound in the diagnosis of abscesses found ultrasound to have a sensitivity and specificity of 96.7% and 85.7%, respectively, while the overall sensitivity and specificity of CT was 76.7% and 91.4%, respectively. Ultrasound was superior in overall image detail ratings and demonstrated more visible detail within the abscess cavity. 5 When utilizing POCUS to evaluate for an abscess, look for an

  11. Comparison of longitudinal excursion of a nerve-phantom model using quantitative ultrasound imaging and motion analysis system methods: A convergent validity study.

    Science.gov (United States)

    Paquette, Philippe; El Khamlichi, Youssef; Lamontagne, Martin; Higgins, Johanne; Gagnon, Dany H

    2017-08-01

    Quantitative ultrasound imaging is gaining popularity in research and clinical settings to measure the neuromechanical properties of the peripheral nerves such as their capability to glide in response to body segment movement. Increasing evidence suggests that impaired median nerve longitudinal excursion is associated with carpal tunnel syndrome. To date, psychometric properties of longitudinal nerve excursion measurements using quantitative ultrasound imaging have not been extensively investigated. This study investigates the convergent validity of the longitudinal nerve excursion by comparing measures obtained using quantitative ultrasound imaging with those determined with a motion analysis system. A 38-cm long rigid nerve-phantom model was used to assess the longitudinal excursion in a laboratory environment. The nerve-phantom model, immersed in a 20-cm deep container filled with a gelatin-based solution, was moved 20 times using a linear forward and backward motion. Three light-emitting diodes were used to record nerve-phantom excursion with a motion analysis system, while a 5-cm linear transducer allowed simultaneous recording via ultrasound imaging. Both measurement techniques yielded excellent association ( r  = 0.99) and agreement (mean absolute difference between methods = 0.85 mm; mean relative difference between methods = 7.48 %). Small discrepancies were largely found when larger excursions (i.e. > 10 mm) were performed, revealing slight underestimation of the excursion by the ultrasound imaging analysis software. Quantitative ultrasound imaging is an accurate method to assess the longitudinal excursion of an in vitro nerve-phantom model and appears relevant for future research protocols investigating the neuromechanical properties of the peripheral nerves.

  12. Quantitative ultrasound characterization of tumor cell death: ultrasound-stimulated microbubbles for radiation enhancement.

    Directory of Open Access Journals (Sweden)

    Hyunjung Christina Kim

    Full Text Available The aim of this study was to assess the efficacy of quantitative ultrasound imaging in characterizing cancer cell death caused by enhanced radiation treatments. This investigation focused on developing this ultrasound modality as an imaging-based non-invasive method that can be used to monitor therapeutic ultrasound and radiation effects. High-frequency (25 MHz ultrasound was used to image tumor responses caused by ultrasound-stimulated microbubbles in combination with radiation. Human prostate xenografts grown in severe combined immunodeficiency (SCID mice were treated using 8, 80, or 1000 µL/kg of microbubbles stimulated with ultrasound at 250, 570, or 750 kPa, and exposed to 0, 2, or 8 Gy of radiation. Tumors were imaged prior to treatment and 24 hours after treatment. Spectral analysis of images acquired from treated tumors revealed overall increases in ultrasound backscatter intensity and the spectral intercept parameter. The increase in backscatter intensity compared to the control ranged from 1.9±1.6 dB for the clinical imaging dose of microbubbles (8 µL/kg, 250 kPa, 2 Gy to 7.0±4.1 dB for the most extreme treatment condition (1000 µL/kg, 750 kPa, 8 Gy. In parallel, in situ end-labelling (ISEL staining, ceramide, and cyclophilin A staining demonstrated increases in cell death due to DNA fragmentation, ceramide-mediated apoptosis, and release of cyclophilin A as a result of cell membrane permeabilization, respectively. Quantitative ultrasound results indicated changes that paralleled increases in cell death observed from histology analyses supporting its use for non-invasive monitoring of cancer treatment outcomes.

  13. Medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2007-01-01

    The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... waves from passing into your body. The sonographer (ultrasound technologist) or radiologist then places the transducer on the skin in various locations, sweeping over the area of interest or angling the ... ultrasound images are reviewed. An ultrasound examination is usually ...

  15. Developing an emergency ultrasound app

    DEFF Research Database (Denmark)

    Foss, Kim Thestrup; Subhi, Yousif; Aagaard, Rasmus

    2015-01-01

    Focused emergency ultrasound is rapidly evolving as a clinical skill for bedside examination by physicians at all levels of education. Ultrasound is highly operator-dependent and relevant training is essential to ensure appropriate use. When supplementing hands-on focused ultrasound courses, e-le...

  16. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    International Nuclear Information System (INIS)

    2015-01-01

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  17. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  18. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  19. Looking forward to new challenges

    Indian Academy of Sciences (India)

    Lawrence

    My interest in a research career began to crystallize about this time, with encouragement ... unique opportunity to work as a post-doctoral fellow with many highly respected scientists at the University of Oxford, Louisiana. State University and ... The SOFC has many metallic parts and we had to develop alloys that performed ...

  20. Looking Forward. The Carbon Markets

    International Nuclear Information System (INIS)

    Wilder, M.

    2006-02-01

    An overview is given of possible future developments in the market for carbon dioxide emissions trading. In this presentation it is concluded that the carbon market is here and now, that the carbon market is global and China and India are major players, that global capital is on the move and delay is dangerous, that there is a world of opportunity for Australian companies and with inaction there is a risk to fall off the fringe

  1. Taking Stock and Looking Forward

    DEFF Research Database (Denmark)

    Toppenberg, Gustav; Henningsson, Stefan

    2014-01-01

    The last decade has seen a rise in research on the topic of challenges associated with information systems (IS) in corporate mergers and acquisitions (M&As). Although this proliferation of research has the potential to significantly improve our understanding of IS challenges in M&A activity, absent...

  2. Special Operations Forces: Looking Forward

    National Research Council Canada - National Science Library

    Shelton, Henry

    1998-01-01

    The article introduces the United States as the sole superpower. As such the U.S. is obligated to assist other countries in need or threatened by adversaries, as long as it's in our national interests. Future U.S...

  3. Looking Forward to... / Sirje Helme

    Index Scriptorium Estoniae

    Helme, Sirje, 1949-

    1998-01-01

    Märtsis 1993. a. asutatud Sorose Kaasaegse Kunsti Eesti Keskuse tegevusest 5 aasta jooksul. Pikemalt aastanäitustest Subject-Unsubject, Non-existent Art, Biotopia. Biology. Technology, Interstanding, Estonia as a Sign.

  4. Physics of Ultrasound. Chapter 12

    Energy Technology Data Exchange (ETDEWEB)

    Lacefield, J. C. [University of Western Ontario, London (Canada)

    2014-09-15

    Ultrasound is the most commonly used diagnostic imaging modality, accounting for approximately 25% of all imaging examinations performed worldwide at the beginning of the 21st century. The success of ultrasound may be attributed to a number of attractive characteristics, including the relatively low cost and portability of an ultrasound scanner, the non-ionizing nature of ultrasound waves, the ability to produce real time images of blood flow and moving structures such as the beating heart, and the intrinsic contrast among soft tissue structures that is achieved without the need for an injected contrast agent. The latter characteristic enables ultrasound to be used for a wide range of medical applications, which historically have primarily included cardiac and vascular imaging, imaging of the abdominal organs and, most famously, in utero imaging of the developing fetus. Ongoing technological improvements continue to expand the use of ultrasound for many applications, including cancer imaging, musculoskeletal imaging, ophthalmology and others. The term ultrasound refers specifically to acoustic waves at frequencies greater than the maximum frequency audible to humans, which is nominally 20 kHz. Diagnostic imaging is generally performed using ultrasound in the frequency range of 2–15 MHz. The choice of frequency is dictated by a trade off between spatial resolution and penetration depth, since higher frequency waves can be focused more tightly but are attenuated more rapidly by tissue. The information contained in an ultrasonic image is influenced by the physical processes underlying propagation, reflection and attenuation of ultrasound waves in tissue.

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... to image by ultrasound because greater amounts of tissue attenuate (weaken) the sound waves as they pass deeper into the body and need to be returned to the transducer for analysis. Ultrasound has difficulty penetrating bone and, therefore, can only see the outer surface ...

  6. [Basics of emergency ultrasound].

    Science.gov (United States)

    Schellhaas, S; Breitkreutz, R

    2012-09-05

    Focused ultrasound is a key methodology of critical care medicine. By referencing few ultrasound differential diagnosis, it is possible to identifying in real-time the reason of the critical state of a patient. Therefore typical focused ultrasound protocols were developed. The well known Focused Assessment with Sonography for trauma (FAST) was incorporated into the Advanced Trauma Life Support (ATLS) for shock room. Focused echocardiographic evaluation in life support (FEEL) has been designed to be conformed with the universal Advanced Life Support (ALS) algorithm and to identify treatable conditions such as acute right ventricular pressure overload in pulmonary embolism, hypovolemia, or pericardial effusion/tamponade. Using lung ultrasound one can differentiate pulmonary edema, pleural effusion or pneumothorax.

  7. LHC production of forward-center and forward-forward di-jets in the kt-factorization and transverse dependent unintegrated parton distribution frameworks

    Science.gov (United States)

    Modarres, M.; Masouminia, M. R.; Aminzadeh Nik, R.; Hosseinkhani, H.; Olanj, N.

    2017-09-01

    The present work is devoted to study the high-energy QCD events, such as the di-jet productions from proton-proton inelastic collisions at the LHC in the forward-center and the forward-forward configurations. This provides us with much valuable case study, since such phenomena can provide a direct glimpse into the partonic behavior of a hadron in a dominant gluonic region. We use the unintegrated parton distribution functions (UPDF) in the kt-factorization framework. The UPDF of Kimber et al. (KMR) and Martin et al. (MRW) are generated in the leading order (LO) and next-to-leading order (NLO), using the Harland-Lang et al. (MMHT2014) PDF libraries. While working in the forward-center and the forward-forward rapidity sectors, one can probe the parton densities at very low longitudinal momentum fractions (x). Such a model computation can provide simpler analytic description of data with respect to existing formalisms such as perturbative QCD. The differential cross-section calculations are performed at the center of mass energy of 7 TeV corresponding to CMS collaboration measurement. It is shown that the gluonic jet productions are dominant and a good description of data as well as other theoretical attempts (i.e. KS-linear, KS-nonlinear and rcBK) is obtained. The uncertainty of the calculations is derived by manipulating the hard scale of the processes by a factor of two. This conclusion is achieved, due to the particular visualization of the angular ordering constraint (AOC), that is incorporated in the definition of these UPDF.

  8. Riding the Plane Wave: Considerations for In Vivo Study Designs Employing High Frame Rate Ultrasound

    Directory of Open Access Journals (Sweden)

    Jason S. Au

    2018-02-01

    Full Text Available Advancements in diagnostic ultrasound have allowed for a rapid expansion of the quantity and quality of non-invasive information that clinical researchers can acquire from cardiovascular physiology. The recent emergence of high frame rate ultrasound (HiFRUS is the next step in the quantification of complex blood flow behavior, offering angle-independent, high temporal resolution data in normal physiology and clinical cases. While there are various HiFRUS methods that have been tested and validated in simulations and in complex flow phantoms, there is a need to expand the field into more rigorous in vivo testing for clinical relevance. In this tutorial, we briefly outline the major advances in HiFRUS, and discuss practical considerations of participant preparation, experimental design, and human measurement, while also providing an example of how these frameworks can be immediately applied to in vivo research questions. The considerations put forward in this paper aim to set a realistic framework for research labs which use HiFRUS to commence the collection of human data for basic science, as well as for preliminary clinical research questions.

  9. Ultrasound call detection in capybara

    Directory of Open Access Journals (Sweden)

    Selene S.C. Nogueira

    2012-07-01

    Full Text Available The vocal repertoire of some animal species has been considered a non-invasive tool to predict distress reactivity. In rats ultrasound emissions were reported as distress indicator. Capybaras[ vocal repertoire was reported recently and seems to have ultrasound calls, but this has not yet been confirmed. Thus, in order to check if a poor state of welfare was linked to ultrasound calls in the capybara vocal repertoire, the aim of this study was to track the presence of ultrasound emissions in 11 animals under three conditions: 1 unrestrained; 2 intermediately restrained, and 3 highly restrained. The ultrasound track identified frequencies in the range of 31.8±3.5 kHz in adults and 33.2±8.5 kHz in juveniles. These ultrasound frequencies occurred only when animals were highly restrained, physically restrained or injured during handling. We concluded that these calls with ultrasound components are related to pain and restraint because they did not occur when animals were free of restraint. Thus we suggest that this vocalization may be used as an additional tool to assess capybaras[ welfare.

  10. Obstetrical ultrasound

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The use of diagnostic ultrasound in obstetrics may provide fuel for legal action. While most legal implications of this relatively new imaging modality are purely speculative, some have already given rise to legal action. Several situations will likely provide a basis for the courts to find against the physician. The failure to perform a sonogram when clinically indicated will most likely be the strongest plaintiff argument. Other major concerns include the use and availability of state-of-the-art equipment, as well as interpretation of the scans by a trained physician. Obstetrical ultrasound is usually performed by a radiologist or obstetrician. However, many physicians performing these examinations have had little or no formal training in the field. While this is now being remedied by the respective board examines who require a certain amount of training, it may not be enough. When ultrasound-related cases reach the courts, the involved physicians will most likely be regarded as experts in the field and, therefore, will be held to a very high standard of care. This would be difficult to achieve without formal training. At the present time, the American Board of Radiology requires more training time in ultrasound than the American Board of Obstetrics and Gynecology

  11. Improved heating efficiency with High-Intensity Focused Ultrasound using a new ultrasound source excitation.

    Science.gov (United States)

    Bigelow, Timothy A

    2009-01-01

    High-Intensity Focused Ultrasound (HIFU) is quickly becoming one of the best methods to thermally ablate tissue noninvasively. Unlike RF or Laser ablation, the tissue can be destroyed without inserting any probes into the body minimizing the risk of secondary complications such as infections. In this study, the heating efficiency of HIFU sources is improved by altering the excitation of the ultrasound source to take advantage of nonlinear propagation. For ultrasound, the phase velocity of the ultrasound wave depends on the amplitude of the wave resulting in the generation of higher harmonics. These higher harmonics are more efficiently converted into heat in the body due to the frequency dependence of the ultrasound absorption in tissue. In our study, the generation of the higher harmonics by nonlinear propagation is enhanced by transmitting an ultrasound wave with both the fundamental and a higher harmonic component included. Computer simulations demonstrated up to a 300% increase in temperature increase compared to transmitting at only the fundamental for the same acoustic power transmitted by the source.

  12. Ultrasound in environmental engineering. Papers

    Energy Technology Data Exchange (ETDEWEB)

    Tiehm, A; Neis, U [eds.

    1999-07-01

    This book presents recent research and state-of-the-art information on the scientific basis, modes of use, and engineering developments of ultrasound application in the field of environmental protection. The information is loosely grouped into the following themes: ultrasound and sonochemistry, design of sonoreactors, applications in water, waste water and sludge treatment: aggregation of suspended particles, degradation of hazardous pollutants, disinfection, disintegration of biosolids. Ultrasound is generated and applied at frequencies from 20 kHz to several MHz. Reactor design, applied intensity, duration of sonication, and physico-chemical parameters of the sonicated media influence ultrasound effects. Thus, ultrasound, at a first glance, is a complex and probably confusing matter. This book has been compiled from presentations held at the first workshop 'Ultrasound in Environmental Engineering' on March 22nd and 23rd, 1999, at the Technical University of Hamburg-Harburg in cooperation with the German Association for the Water Environment (ATV) and the DECHEMA e.V. (orig.)

  13. Ultrasound in environmental engineering. Papers

    Energy Technology Data Exchange (ETDEWEB)

    Tiehm, A.; Neis, U. [eds.

    1999-07-01

    This book presents recent research and state-of-the-art information on the scientific basis, modes of use, and engineering developments of ultrasound application in the field of environmental protection. The information is loosely grouped into the following themes: ultrasound and sonochemistry, design of sonoreactors, applications in water, waste water and sludge treatment: aggregation of suspended particles, degradation of hazardous pollutants, disinfection, disintegration of biosolids. Ultrasound is generated and applied at frequencies from 20 kHz to several MHz. Reactor design, applied intensity, duration of sonication, and physico-chemical parameters of the sonicated media influence ultrasound effects. Thus, ultrasound, at a first glance, is a complex and probably confusing matter. This book has been compiled from presentations held at the first workshop 'Ultrasound in Environmental Engineering' on March 22nd and 23rd, 1999, at the Technical University of Hamburg-Harburg in cooperation with the German Association for the Water Environment (ATV) and the DECHEMA e.V. (orig.)

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... women and their unborn babies. Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  15. China in space the great leap forward

    CERN Document Server

    Harvey, Brian

    2013-01-01

    The 21st century has seen the emergence, after the Soviet Union and the United States, of the third great space superpower: China. Here, in China in Space - The Great Leap Forward, Brian Harvey takes a contemporary look at the new Chinese space program. China has already launched its first space station, Tiangong; has sent its first spacecraft to the Moon, the Chang e; and has plans to send spaceships to Mars and further afield. China's annual launch rate has already overtaken those of both Europe and the United States. Huge new production plants and launch centers are under construction, to build and launch the new family of Long March 5, 6, and 7 rockets. In Roadmap 2050, the Academy of Sciences indicates that China intends to be the leading spacefaring nation by mid-century, with bases on the Moon and Mars. This book gives an informed, fully up-to-date commentary on all aspects of the Chinese space program, including its history, development, technology, missions, and the personalities involved. It lists a...

  16. Molecular ultrasound imaging: current status and future directions

    International Nuclear Information System (INIS)

    Deshpande, N.; Needles, A.; Willmann, J.K.

    2010-01-01

    Targeted contrast-enhanced ultrasound (molecular ultrasound) is an emerging imaging strategy that combines ultrasound technology with novel molecularly-targeted ultrasound contrast agents for assessing biological processes at the molecular level. Molecular ultrasound contrast agents are nano- or micro-sized particles that are targeted to specific molecular markers by adding high-affinity binding ligands onto the surface of the particles. Following intravenous administration, these targeted ultrasound contrast agents accumulate at tissue sites overexpressing specific molecular markers, thereby enhancing the ultrasound imaging signal. High spatial and temporal resolution, real-time imaging, non-invasiveness, relatively low costs, lack of ionising irradiation and wide availability of ultrasound systems are advantages compared to other molecular imaging modalities. In this article we review current concepts and future directions of molecular ultrasound imaging, including different classes of molecular ultrasound contrast agents, ongoing technical developments of pre-clinical and clinical ultrasound systems, the potential of molecular ultrasound for imaging different diseases at the molecular level, and the translation of molecular ultrasound into the clinic.

  17. In-111-oxine labeled platelet scintigraphy for detection of intracardiac and intravascular thrombi

    Energy Technology Data Exchange (ETDEWEB)

    Hanano, Masaharu; Kimura, Michio; Ojima, Kenji [Niigata Univ. (Japan). School of Medicine

    1984-06-01

    /sup 111/In-labeled platelet scintigraphy was carried out in 20 patients suspected of thrombosis, to evaluate its efficacy for the detection of intracardiac and intravascular thrombi. Hemostatic studies including PT, aPTT, fibrinogen, FDP, platelet retention by Hellem II method, platelet aggregation induced by ADP (1 ..mu..M, 10 ..mu..M), collagen (2 ..mu..g/ml) and arachidonate (2 mM), and platelet survival were examined simultaneously. Two of these patients were also studied by fibrinogen scintigraphy labeled with sup(99m)Tc. The platelets obtained from the patients were labeled with /sup 111/In-oxine according to a method originated by Yui et al. In the platelet scintigram, positive findings were demonstrated in 9 cases : 2 left ventricular, 3 left atrial, and 4 vascular thrombi. These were in a good accordance to the findings obtained by at least one from angiography, echography and surgery. Platelet aggregation induced by 1 ..mu..M ADP was elevated in 4 of the 7 patients with positive findings and 3 of the 7 patients with negative findings. Shortened platelet survivals were observed in two of the 10 patients; dissecting aortic aneurysm and infective prosthetic valve endocarditis with hepatosplenomegaly. There was no significant difference in the platelet function and the platelet survival between the patients with positive and negative findings. It was difficult to detect thrombi by the fibrinogen scintigraphy labeled with sup(99m)Tc in the two patients studied. In conclusion, /sup 111/In-labeled platelet scintigraphy seems to be very useful to detect thrombi.

  18. STS-46 'blue' shift crewmembers look up from work on OV-104's flight deck

    Science.gov (United States)

    1992-01-01

    STS-46 'blue' shift crewmembers look up from checklist procedures to have their picture taken on the forward flight deck of Atlantis, Orbiter Vehicle (OV) 104. Seated at the commanders station (left) is Pilot Andrew M. Allen with Italian Payload Specialist Franco Malerba positioned in front of the center console and European Space Agency (ESA) Mission Specialist seated at the pilots station (right). MS Marsha S. Ivins is in the interdeck access hatch at the right bottom corner of the photo.

  19. Prostate ultrasound: back in business!

    Science.gov (United States)

    Crisan, Nicolae; Andras, Iulia; Radu, Corina; Andras, David; Coman, Radu-Tudor; Tucan, Paul; Pisla, Doina; Crisan, Dana; Coman, Ioan

    2017-11-29

    The use of grey scale prostate ultrasound decreased after the implementation of magnetic resonance imaging (MRI) for the diagnosis and evaluation of prostate cancer. The new developments, such as multiparametric ultrasound and MRI-ultrasound fusion technology, renewed the interest for this imaging method in the assessment of prostate cancer. The purpose of this paper was to review the current role of prostate ultrasound in the setting of these new applications. A thorough reevaluation of the selection criteria of the patients is required to assess which patients would benefit from multiparametric ultrasound, who wouldbenefit from multiparametric MRI or the combination of both to assist prostate biopsy in order to ensure the balance between overdiagnosis and underdiagnosis of prostate cancer.

  20. Conservation laws arising in the study of forward-forward Mean-Field Games

    KAUST Repository

    Gomes, Diogo A.; Nurbekyan, Levon; Sedjro, Marc

    2017-01-01

    We consider forward-forward Mean Field Game (MFG) models that arise in numerical approximations of stationary MFGs. First, we establish a link between these models and a class of hyperbolic conservation laws as well as certain nonlinear wave equations. Second, we investigate existence and long-time behavior of solutions for such models.

  1. Conservation laws arising in the study of forward-forward Mean-Field Games

    KAUST Repository

    Gomes, Diogo A.

    2017-04-24

    We consider forward-forward Mean Field Game (MFG) models that arise in numerical approximations of stationary MFGs. First, we establish a link between these models and a class of hyperbolic conservation laws as well as certain nonlinear wave equations. Second, we investigate existence and long-time behavior of solutions for such models.

  2. From 4D Medical Images (CT, MRI, and Ultrasound to 4D Structured Mesh Models of the Left Ventricular Endocardium for Patient-Specific Simulations

    Directory of Open Access Journals (Sweden)

    Federico Canè

    2018-01-01

    Full Text Available With cardiovascular disease (CVD remaining the primary cause of death worldwide, early detection of CVDs becomes essential. The intracardiac flow is an important component of ventricular function, motion kinetics, wash-out of ventricular chambers, and ventricular energetics. Coupling between Computational Fluid Dynamics (CFD simulations and medical images can play a fundamental role in terms of patient-specific diagnostic tools. From a technical perspective, CFD simulations with moving boundaries could easily lead to negative volumes errors and the sudden failure of the simulation. The generation of high-quality 4D meshes (3D in space + time with 1-to-1 vertex becomes essential to perform a CFD simulation with moving boundaries. In this context, we developed a semiautomatic morphing tool able to create 4D high-quality structured meshes starting from a segmented 4D dataset. To prove the versatility and efficiency, the method was tested on three different 4D datasets (Ultrasound, MRI, and CT by evaluating the quality and accuracy of the resulting 4D meshes. Furthermore, an estimation of some physiological quantities is accomplished for the 4D CT reconstruction. Future research will aim at extending the region of interest, further automation of the meshing algorithm, and generating structured hexahedral mesh models both for the blood and myocardial volume.

  3. Simulation Results of Double Forward Converter

    Directory of Open Access Journals (Sweden)

    P. Vijaya KUMAR

    2009-12-01

    Full Text Available This work aims to find a better forward converter for DC to DC conversion.Simulation of double forward converter in SMPS system is discussed in this paper. Aforward converter with RCD snubber to synchronous rectifier and/or to current doubleris also discussed. The evolution of the forward converter is first reviewed in a tutorialfashion. Performance parameters are discussed including operating principle, voltageconversion ratio, efficiency, device stress, small-signal dynamics, noise and EMI. Itscircuit operation and its performance characteristics of the forward converter with RCDsnubber and double forward converter are described and the simulation results arepresented.

  4. Forward energy measurement with CMS

    CERN Document Server

    Kheyn, Lev

    2016-01-01

    Energy flow is measured in the forward region of CMS at pseudorapidities up to 6.6 in pp interactions at 13 TeV with forward (HF) and very forward (CASTOR) calorimeters. The results are compared to model predictions. The CMS results at different center-of-mass energies are intercompared using pseudorapidity variable shifted by beam rapidity, thus studying applicability of hypothesis of limiting fragmentation.

  5. Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study.

    Science.gov (United States)

    Leite, Luiz R; Santos, Simone N; Maia, Henrique; Henz, Benhur D; Giuseppin, Fábio; Oliverira, Anderson; Zanatta, André R; Peres, Ayrton K; Novakoski, Clarissa; Barreto, Jose R; Vassalo, Fabrício; d'Avila, Andre; Singh, Sheldon M

    2011-04-01

    Luminal esophageal temperature (LET) monitoring is one strategy to minimize esophageal injury during atrial fibrillation ablation procedures. However, esophageal ulceration and fistulas have been reported despite adequate LET monitoring. The objective of this study was to assess a novel approach to LET monitoring with a deflectable LET probe on the rate of esophageal injury in patients undergoing atrial fibrillation ablation. Forty-five consecutive patients undergoing an atrial fibrillation ablation procedure followed by esophageal endoscopy were included in this prospective observational pilot study. LET monitoring was performed with a 7F deflectable ablation catheter that was positioned as close as possible to the site of left atrial ablation using the deflectable component of the catheter guided by visualization of its position on intracardiac echocardiography. Ablation in the posterior left atrial was limited to 25 W and terminated when the LET increased 2°C from baseline. Endoscopy was performed 1 to 2 days after the procedure. All patients had at least 1 LET elevation >2°C necessitating cessation of ablation. Deflection of the LET probe was needed to accurately measure LET in 5% of patients when ablating near the left pulmonary veins, whereas deflection of the LET probe was necessary in 88% of patients when ablating near the right pulmonary veins. The average maximum increase in LET was 2.5±1.5°C. No patients had esophageal thermal injury on follow-up endoscopy. A strategy of optimal LET probe placement using a deflectable LET probe and intracardiac echocardiography guidance, combined with cessation of radiofrequency ablation with a 2°C rise in LET, may reduce esophageal thermal injury during left atrial ablation procedures.

  6. Ethical analysis of non-medical fetal ultrasound.

    Science.gov (United States)

    Leung, John Lai Yin; Pang, Samantha Mei Che

    2009-09-01

    Obstetric ultrasound is the well-recognized prenatal test used to visualize and determine the condition of a pregnant woman and her fetus. Apart from the clinical application, some businesses have started promoting the use of fetal ultrasound machines for nonmedical reasons. Non-medical fetal ultrasound (also known as 'keepsake' ultrasound) is defined as using ultrasound to view, take a picture, or determine the sex of a fetus without a medical indication. Notwithstanding the guidelines and warnings regarding ultrasound safety issued by governments and professional bodies, the absence of scientifically proven physical harm to fetuses from this procedure seems to provide these businesses with grounds for rapid expansion. However, this argument is too simplistic because current epidemiological evidence is not synchronous with advancing ultrasound technology. As non-medical fetal ultrasound has aroused very significant public attention, a thorough ethical analysis of this topic is essential. Using a multifaceted approach, we analyse the ethical perspective of non-medical fetal ultrasound in terms of the expectant mother, the fetus and health professionals. After applying four major theories of ethics and principles (the precautionary principle; theories of consequentialism and impartiality; duty-based theory; and rights-based theories), we conclude that obstetric ultrasound practice is ethically justifiable only if the indication for its use is based on medical evidence. Non-medical fetal ultrasound can be considered ethically unjustifiable. Nevertheless, the ethical analysis of this issue is time dependent owing to rapid advancements in ultrasound technology and the safety issue. The role of health professionals in ensuring that obstetric ultrasound is an ethically justifiable practice is also discussed.

  7. Doppler ultrasound for diagnosis of soft tissue sarcoma: efficacy of ultrasound-based screening score

    Directory of Open Access Journals (Sweden)

    Nagano Satoshi

    2015-06-01

    Full Text Available Background. The utility of ultrasound imaging in the screening of soft-part tumours (SPTs has been reported. We classified SPTs according to their blood flow pattern on Doppler ultrasound and re-evaluated the efficacy of this imaging modality as a screening method. Additionally, we combined Doppler ultrasound with several values to improve the diagnostic efficacy and to establish a new diagnostic tool.

  8. Development of Flexible Capacitive Ultrasound Transducers and the Use of Ultrasound for Bone Repair

    Science.gov (United States)

    Wentzell, Scott A.

    Ultrasound is a widely applicable technique for therapy in the biomedical arena. However, conventional ultrasound transducers are not conducive for non-planar surfaces. Therefore, we developed flexible transducers capable of performing ultrasound and evaluated their use in biomedical applications. Flexible capacitive ultrasound transducers based on micrometer-thick dielectric tapes were developed and fabricated. These transducers were able to be made by hand at low-cost while still demonstrating good tolerances in center operating frequency. Intensities of up to 120 mW/cm2 were recorded and operation was dependent upon the applied AC and DC voltages along with the thickness of the dielectric insulation. These capacitive ultrasound transducers were used to stimulate MC3T3-E1 murine osteoblast cells to investigate the effects of low-frequency ultrasound on osteogenic gene expression and anabolic signaling pathways. After stimulation by 94.5 kHz continuous wave ultrasound for 20 minutes, significant increases in the activation of the Wnt signaling pathway and concentration of intracellular calcium were observed. Daily stimulation by ultrasound showed a trend of increased osteogenic gene expression across the phases of matrix deposition, maturation and calcification by osteoblasts. Finally, the heating of osteoblasts for stimulating osteoclastogenic responses was investigated. The application of increased temperatures of 42 and 47 degrees Celsius for 5 minutes showed significant increases in the RANKL/OPG ratio in media conditioned by osteoblasts. However, the altered RANKL/OPG ratio was not able to generate increases in osteoclastogenesis for RAW 264.7 murine macrophage cells culture in the condition media. This was possibly due to high overall osteoprotegerin expression, or unwanted inducement of M1 and M2 macrophage activation in the cell population. The overall work of this thesis demonstrates the development of novel capacitive transducers. These conformable

  9. Network Analysis in Community Psychology: Looking Back, Looking Forward

    OpenAIRE

    Neal, Zachary P.; Neal, Jennifer Watling

    2017-01-01

    Highlights Network analysis is ideally suited for community psychology research because it focuses on context. Use of network analysis in community psychology is growing. Network analysis in community psychology has employed some potentially problematic practices. Recommended practices are identified to improve network analysis in community psychology.

  10. Looking Forward to Look Backward: Technology and King Arthur

    Science.gov (United States)

    Thomas, Jennifer D. E.; Driver, Martha; Coppola, Jean F.; Thomas, Barbara A.

    2008-01-01

    This article discusses students' perceptions of the impact of technology integration in an interdisciplinary medieval English literature and multimedia course on developing higher-order thinking skills and team-building skills. The results indicate that undergraduate students in this course perceived generally strong support for development of…

  11. Academic literacies: looking back in order to look forward

    Directory of Open Access Journals (Sweden)

    Mary R Lea

    2016-12-01

    Full Text Available This paper argues that we need to reclaim the institutional perspective that was inherent in some of the early work in the field of academic literacies. It offers a brief overview of the emergence of the field and examines some key developments, including an examination of areas of tension with regard to the use of the term academic literacies. It also points to the ways in which the field is drawing in valuable and complementary theoretical and methodological frames, latterly with respect to significant developments in the digital landscape in higher education. The author concludes that academic literacies researchers have ongoing work to do with regard to the changing contexts of higher education and the need to push against the relentless redefinition of the university for its commercial and transfer value as opposed to its intellectual or critical value.

  12. Misrepresenting Religious Education's Past and Present in Looking Forward: Gearon Using Kuhn's Concepts of Paradigm, Paradigm Shift and Incommensurability

    Science.gov (United States)

    Jackson, Robert

    2015-01-01

    In looking to the future, some writers on religious education (RE) have attempted to evaluate current approaches to the subject. Some have characterised any significant change in approach as a "paradigm shift", a term derived from Thomas Kuhn's work in the philosophy of science. This article examines the uses of the terms…

  13. Advantages and application of forward osmosis

    Science.gov (United States)

    This month's Processing column explores the use of forward osmosis to dewater and concentrate. Forward osmosis is performed with specially designed membranes and requires very little energy. Where thermal evaporation and reverse osmosis may damage or alter products, forward osmosis preserves the s...

  14. Ultrasound appearance of knuckle pads

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Ben, R. [Univ. of Alabama, Birmingham (United States). Dept. of Diagnostic Radiology; Dehghanpisheh, K.; Chatham, W.W.; Alarcon, G.S. [Univ. of Alabama, Birmingham (United States). Dept. of Medicine; Lee, D.H.; Oakes, J. [Univ. of Alabama, Birmingham (United States). Dept. of Surgery

    2006-11-15

    We describe the ultrasound appearance of knuckle pads. Retrospective analysis of imaging in a series of five patients initially referred for evaluation of periarticular soft-tissue swelling of the hands involving the dorsum of the PIP and MP joints. Two patients had associated Dupuytren's contractures. Ultrasound and radiographs of the hands in all patients were reviewed and correlated with clinical history and physical exams. Radiographs in four patients demonstrated dorsal soft-tissue thickening. Ultrasound exams showed increased dorsal subcutaneous thickening, with either diffuse or focal hypoechoic areas corresponding to the areas of soft-tissue fullness identified on physical exam. No erosions or synovial proliferation were identified either by radiographs or ultrasound of the underlying joints. Knuckle pads can sometimes be difficult to distinguish from synovitis on physical examination. Musculoskeletal ultrasound can quickly identify these superficial lesions and exclude underlying synovial proliferation.

  15. Going forward with genetics: recent technological advances and forward genetics in mice.

    Science.gov (United States)

    Moresco, Eva Marie Y; Li, Xiaohong; Beutler, Bruce

    2013-05-01

    Forward genetic analysis is an unbiased approach for identifying genes essential to defined biological phenomena. When applied to mice, it is one of the most powerful methods to facilitate understanding of the genetic basis of human biology and disease. The speed at which disease-causing mutations can be identified in mutagenized mice has been markedly increased by recent advances in DNA sequencing technology. Creating and analyzing mutant phenotypes may therefore become rate-limiting in forward genetic experimentation. We review the forward genetic approach and its future in the context of recent technological advances, in particular massively parallel DNA sequencing, induced pluripotent stem cells, and haploid embryonic stem cells. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  16. The ATLAS Forward Physics Program

    OpenAIRE

    Royon, C

    2010-01-01

    After a brief review of the approved ATLAS forward detector system we describe the main ATLAS forward physics program. This program currently includes such topics as soft and hard diffraction, double pomeron exchange, central exclusive production, rapidity gap survival, two photon physics, the determination of the total cross-section and the determination of the absolute luminosity A possible high luminosity upgrade program involving new forward proton detectors is also briefly reviewed. This...

  17. Diagnostic significance of ultrasound in dermatology

    OpenAIRE

    Stojanović Slobodan; Poljački Mirjana N.; Roš Tatjana

    2002-01-01

    Introduction Utilization of 20 MHz ultrasound probes provided application of ultrasound in dermatology - dermatosonography. As a diagnostic tool, ultrasound was first registered in the early fifties of the past century. Great progress of dermatosonography occurred in the mid-nineties with introduction of the first 20 MHz scanner. Methods of ultrasonography in dermatology Several methods of ultrasonography have been developed: method A, method B, scanning C method and Doppler ultrasound. They ...

  18. Good Looking Is Looking Good / Märt Milter

    Index Scriptorium Estoniae

    Milter, Märt

    1998-01-01

    Meloodilist drum ǹ̀bassi viljelevatest välismaa plaadifirmadest Good Looking Recordsist ja Looking Good Recordsist, mida juhib LTJ Bukem ja temaga koostööd tegevatest muusikutest Blame, Seba, Tayla, MC Conrad, Artemis

  19. Objective and structured assessment of lung ultrasound competence

    DEFF Research Database (Denmark)

    Skaarup, Søren Helbo; Laursen, Christian B.; Bjerrum, Anne Sofie

    2017-01-01

    RATIONALE: Point-of-care lung ultrasound imaging has substantial diagnostic value and is widely used in respiratory, emergency and critical care medicine. Like other ultrasound examinations, lung ultrasound is operator-dependent. The current recommendations for competence in lung ultrasound sets...... a fixed number of ultrasound procedures to be performed without considering different learning rates. Recommendations do not consider different uses of lung ultrasound across specialties. OBJECTIVE: To create a reliable, valid and feasible instrument to assess lung ultrasound competence that includes...... 23 ultrasound operators of different competence levels. Examination time was measured and skill was rated by experienced observers using the assessment tool. Inter-rater agreement was examined by two observers in 9 lung ultrasound examinations. RESULTS: Consensus was obtained within 3 Delphi rounds...

  20. Holistic ultrasound in trauma: An update.

    Science.gov (United States)

    Saranteas, Theodosios; Mavrogenis, Andreas F

    2016-10-01

    Holistic ultrasound is a total body examination using an ultrasound device aiming to achieve immediate patient care and decision making. In the setting of trauma, it is one of the most fundamental components of care of the injured patients. Ground-breaking imaging software allows physicians to examine various organs thoroughly, recognize imaging signs early, and potentially foresee the onset or the possible outcome of certain types of injuries. Holistic ultrasound can be performed on a routine basis at the bedside of the patients, at admission and during the perioperative period. Trauma care physicians should be aware of the diagnostic and guidance benefits of ultrasound and should receive appropriate training for the optimal management of their patients. In this paper, the findings of holistic ultrasound in trauma patients are presented, with emphasis on the lungs, heart, cerebral circulation, abdomen, and airway. Additionally, the benefits of ultrasound imaging in interventional anaesthesia techniques such as ultrasound-guided peripheral nerve blocks and central vein catheterization are described. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    Science.gov (United States)

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Defence against Black Hole and Selective Forwarding Attacks for Medical WSNs in the IoT

    Directory of Open Access Journals (Sweden)

    Avijit Mathur

    2016-01-01

    Full Text Available Wireless sensor networks (WSNs are being used to facilitate monitoring of patients in hospital and home environments. These systems consist of a variety of different components/sensors and many processes like clustering, routing, security, and self-organization. Routing is necessary for medical-based WSNs because it allows remote data delivery and it facilitates network scalability in large hospitals. However, routing entails several problems, mainly due to the open nature of wireless networks, and these need to be addressed. This paper looks at two of the problems that arise due to wireless routing between the nodes and access points of a medical WSN (for IoT use: black hole and selective forwarding (SF attacks. A solution to the former can readily be provided through the use of cryptographic hashes, while the latter makes use of a neighbourhood watch and threshold-based analysis to detect and correct SF attacks. The scheme proposed here is capable of detecting a selective forwarding attack with over 96% accuracy and successfully identifying the malicious node with 83% accuracy.

  3. Defence against Black Hole and Selective Forwarding Attacks for Medical WSNs in the IoT.

    Science.gov (United States)

    Mathur, Avijit; Newe, Thomas; Rao, Muzaffar

    2016-01-19

    Wireless sensor networks (WSNs) are being used to facilitate monitoring of patients in hospital and home environments. These systems consist of a variety of different components/sensors and many processes like clustering, routing, security, and self-organization. Routing is necessary for medical-based WSNs because it allows remote data delivery and it facilitates network scalability in large hospitals. However, routing entails several problems, mainly due to the open nature of wireless networks, and these need to be addressed. This paper looks at two of the problems that arise due to wireless routing between the nodes and access points of a medical WSN (for IoT use): black hole and selective forwarding (SF) attacks. A solution to the former can readily be provided through the use of cryptographic hashes, while the latter makes use of a neighbourhood watch and threshold-based analysis to detect and correct SF attacks. The scheme proposed here is capable of detecting a selective forwarding attack with over 96% accuracy and successfully identifying the malicious node with 83% accuracy.

  4. Soleus muscle injury: sensitivity of ultrasound patterns

    Energy Technology Data Exchange (ETDEWEB)

    Balius, Ramon [Sport Catalan Council, Generalitat de Catalunya, Barcelona (Spain); Clinica CMI Diagonal, Barcelona (Spain); Rodas, Gil [F.C. Barcelona Medical Services, Barcelona (Spain); Pedret, Carles [Clinica CMI Diagonal, Barcelona (Spain); Clinica Mapfre de Medicina del Tenis, Sports Medicine and Imaging Department, Barcelona (Spain); Centre de Diagnostic per Imatge de Tarragona, Tarragona (Spain); Capdevila, Lluis [Universitat Autonoma de Barcelona, Laboratory of Sport Psychology, Barcelona (Spain); Alomar, Xavier [Clinica Creu Blanca, Barcelona (Spain); Bong, David A. [Instituto Poal de Reumatologia, Barcelona (Spain)

    2014-06-15

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the ''gold standard.'' In MRI studies, 24 cases (43.7 %) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3 %) and in the anterior aponeurosis (AMF) in 9 (16.4 %). Thirty-one cases (56.3 %) were musculotendinous injuries, with 9 cases (16.4 %) in the medial aponeurosis (MMT), 11 cases (20 %) in the lateral aponeurosis (LMT), and 11 cases (20 %) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2 % of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area. (orig.)

  5. Soleus muscle injury: sensitivity of ultrasound patterns.

    Science.gov (United States)

    Balius, Ramon; Rodas, Gil; Pedret, Carles; Capdevila, Lluís; Alomar, Xavier; Bong, David A

    2014-06-01

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the "gold standard." In MRI studies, 24 cases (43.7%) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3%) and in the anterior aponeurosis (AMF) in 9 (16.4%). Thirty-one cases (56.3%) were musculotendinous injuries, with 9 cases (16.4%) in the medial aponeurosis (MMT), 11 cases (20%) in the lateral aponeurosis (LMT), and 11 cases (20%) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2% of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area.

  6. Soleus muscle injury: sensitivity of ultrasound patterns

    International Nuclear Information System (INIS)

    Balius, Ramon; Rodas, Gil; Pedret, Carles; Capdevila, Lluis; Alomar, Xavier; Bong, David A.

    2014-01-01

    To assess the sensitivity of ultrasound in detecting soleus muscle lesions diagnosed on magnetic resonance imaging (MRI) and to characterize their location, ultrasound pattern, and evolution. Ultrasound and MRI studies were performed between May 2009 and February 2013 on all patients who presented to the Medical Services Clinic of the Catalan Sport Council with the initial onset of sharp pain in the calf compatible with injury of the soleus muscle. An inter-observer ultrasound reliability study was also performed. A total of 55 cases of soleus injury were studied prospectively (22 with right leg involvement, 33 left) by ultrasound and MRI, which was utilized as the ''gold standard.'' In MRI studies, 24 cases (43.7 %) had myofascial injuries that were localized in the posterior aponeurosis (PMF) in 15 cases (27.3 %) and in the anterior aponeurosis (AMF) in 9 (16.4 %). Thirty-one cases (56.3 %) were musculotendinous injuries, with 9 cases (16.4 %) in the medial aponeurosis (MMT), 11 cases (20 %) in the lateral aponeurosis (LMT), and 11 cases (20 %) in the central tendon (CMT). In comparison to MRI, ultrasound was able to detect injury to the soleus in 27.2 % of cases. No injuries were detected by ultrasound alone. Posterior myofascial injuries were more likely to be detected by ultrasound than anterior myofascial injuries or all types of musculotendinous injuries. Ultrasound patterns for each type of injury were described. Ultrasound is not a sensitive technique for detecting and assessing soleus traumatic tears compared with MRI, although the sensitivity is enhanced by a thorough anatomically based ultrasound examination. Timing of the ultrasound examination may be of importance. Each type of soleus injury appears to have a characteristic ultrasound pattern based on a defect of connective expansions, the existence of small myofascial filiform collections, and the rarefaction of the fibrillar area. (orig.)

  7. Crystallization of glycine with ultrasound

    DEFF Research Database (Denmark)

    Louhi-Kultanen, Marjatta; Karjalainen, Milja; Rantanen, Jukka

    2006-01-01

    Sonocrystallization has proved to be an efficient tool to influence the external appearance and structure of a crystalline product obtained by various crystallization methods. The present work focuses on high intensity sonocrystallization of glycine by varying amplitude of ultrasound with an ultr...... ultrasound power. This study also showed, the higher the ultrasound amplitude the smaller the crystals obtained.......Sonocrystallization has proved to be an efficient tool to influence the external appearance and structure of a crystalline product obtained by various crystallization methods. The present work focuses on high intensity sonocrystallization of glycine by varying amplitude of ultrasound...... with an ultrasound frequency of 20kHz at two temperature ranges 40-50 and 20-30 degrees C in a jacketed 250-ml cooling crystallizer equipped with a stirrer. The polymorph composition of the obtained crystals was analyzed with a temperature variable X-ray powder diffractometer (XRPD). XRPD results showed that...

  8. A virtual radiation belt observatory: Looking forward to the electronic geophysical year

    Science.gov (United States)

    Baker, D. N.; Green, J. C.; Kroehl, H. W.; Kihn, E.; Virbo Team

    During the International Geophysical Year (1957-1958), member countries established many new capabilities pursuing the major IGY objectives of collecting geophysical data as widely as possible and providing free access to these data for all scientists around the globe. A key achievement of the IGY was the establishment of a worldwide system of data centers and physical observatories. The worldwide scientific community has now endorsed and is promoting an electronic Geophysical Year (eGY) initiative. The proposed eGY concept would both commemorate the 50th anniversary of the IGY in 2007-2008 and would provide a forward impetus to geophysics in the 21st century, similar to that provide by the IGY fifty years ago. The eGY concept advocates the establishment of a series of virtual geophysical observatories now being deployed in cyberspace. We are developing the concept of a Virtual Radiation Belt Observatory (ViRBO) that will bring together near-earth particle and field measurements acquired by NASA, NOAA, DoD, DOE, and other spacecraft. We discuss plans to aggregate these measurements into a readily accessible database along with analysis, visualization, and display tools that will make radiation belt information available and useful both to the scientific community and to the user community. We envision that data from the various agencies along with models being developed under the auspices of the National Science Foundation Center for Integrated Space Weather Modeling (CISM) will help us to provide an excellent `climatology' of the radiation belts over the past several decades. In particular, we would plan to use these data to drive physical models of the radiation belts to form a gridded database which would characterize particle and field properties on solar-cycle (11-year) time scales. ViRBO will also provide up-to-date specification of conditions for event analysis and anomaly resolution. We are even examining the possibilities for near-realtime acquisition of

  9. Droplets, Bubbles and Ultrasound Interactions.

    Science.gov (United States)

    Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.

  10. Performing Labour in Look Left Look Right's "Above and Beyond"

    Science.gov (United States)

    Alston, Adam

    2015-01-01

    This article looks at the theme of "performing labour" in Look Left Look Right's "Above and Beyond" (2013). In this performance, individual audience members participate as a generic staff member in a fully functioning five star hotel in London. I consider three modes of performing labour in "Above and Beyond":…

  11. Forward contract - minimize the exchange risk

    OpenAIRE

    Martin Maršík; František Vebr

    1998-01-01

    How can a Czech export (import) company hedge exchange risk? Some of the possibilities are these: 1/ use only CZK for foreign contracts; 2/ matching payments in the same or a parallel currency; 3/ use the products of the money markets; 4/ use the products of the forward market - FORWARD CONTRACT The forward market offers a forward contract to buy or sell a fixed amount of currency at a fixed price on a specific date in the future. The settlement of the contract is in more than two days. The e...

  12. Unpowered wireless transmission of ultrasound signals

    International Nuclear Information System (INIS)

    Huang, H; Paramo, D; Deshmukh, S

    2011-01-01

    This paper presents a wireless ultrasound sensing system that uses frequency conversion to convert the ultrasound signal to a microwave signal and transmit it directly without digitization. Constructed from a few passive microwave components, the sensor is able to sense, modulate, and transmit the full waveform of ultrasound signals wirelessly without requiring any local power source. The principle of operation of the unpowered wireless ultrasound sensor is described first, and this is followed by a detailed description of the implementation of the sensor and the sensor interrogation unit using commercially available antennas and microwave components. Validation of the sensing system using an ultrasound pitch–catch system and the power analysis model of the system are also presented

  13. Radiological assessment of the placement of Essure® in order to reduce hysterosalpingography: Pelvic X-ray versus combined pelvic X-ray and ultrasound.

    Science.gov (United States)

    Petit, C; Vernet, T; Verpillat, P; Rubod, C; Cosson, M; Giraudet, G

    2017-10-01

    Three months after hysteroscopic sterilisation with Essure ® , a confirmation test is required to evaluate the correct location of the inserts. The test may be conducted using a pelvic ultrasound (2D or 3D) or an abdominal X-ray. Should the location not look satisfactory on these tests, a follow-up hysterosalpingography (HSG) would be required. The objective of our study is to assess whether the Essure ® 3-month confirmation test using a single X-ray or a combination of X-ray and ultrasound could reduce the use of HSG. This retrospective study examined patients who underwent birth control Essure ® procedure between 2009 and 2015 in the Gynaecological Surgery Department at the Regional University Hospital Centre (CHRU) in Lille. We divided patients into two groups based on the imaging tests performed: single X-ray (2009-2010) versus X-ray and pelvic ultrasound (2014-2015). We then compared the results of the imaging tests and the use of HSG between the two groups. One hundred and thirty-four patients were tested, of which 60 (44.8%) using a single X-ray and 74 (55.2%) using a combination of X-ray and ultrasound. We note that the combined X-ray/ultrasound test reduces significantly the number of HSG performed (26.7% versus 12.2%, P=0.04). Compared to a single X-ray, the combination of X-ray and ultrasound enables to significantly limit the use of HSG. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. Forward Jet Vertex Tagging: A new technique for the identification and rejection of forward pileup jets

    CERN Document Server

    The ATLAS collaboration

    2015-01-01

    The suppression of pileup forward jets is crucial for a variety of physics analyses at the LHC, ranging from VBF Higgs production to SUSY searches. A novel forward pileup tagging technique that exploits the correlation between central and forward jets originating from pileup interactions is presented. Tracking and vertex information in the central $\\eta$ region is used to indirectly tag and reject forward pileup jets that are back-to-back to central pileup jets. The pileup suppression power observed in Pythia8 simulated events increases with jet \\pt and ranges between a 30\\% and 60\\% pileup jet removal for 90\\% jet selection efficiency for jets between 20 and 50 GeV.

  15. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  16. Adaptive Beamforming for Medical Ultrasound Imaging

    DEFF Research Database (Denmark)

    Holfort, Iben Kraglund

    This dissertation investigates the application of adaptive beamforming for medical ultrasound imaging. The investigations have been concentrated primarily on the Minimum Variance (MV) beamformer. A broadband implementation of theMV beamformer is described, and simulated data have been used...... to demonstrate the performance. The MV beamformer has been applied to different sets of ultrasound imaging sequences; synthetic aperture ultrasound imaging and plane wave ultrasound imaging. And an approach for applying MV optimized apodization weights on both the transmitting and the receiving apertures...

  17. Ultrasound-induced radical polymerization

    NARCIS (Netherlands)

    Kuijpers, M.W.A.; Kemmere, M.F.; Keurentjes, J.T.F.

    2004-01-01

    Sonochemistry comprises all chemical effects that are induced by ultrasound. Most of these effects are caused by cavitations, ie, the collapse of microscopic bubbles in a liquid. The chemical effects of ultrasound include the formation of radicals and the enhancement of reaction rates at ambient

  18. Performance of chest ultrasound in pediatric pneumonia

    Energy Technology Data Exchange (ETDEWEB)

    Claes, Anne-Sophie, E-mail: anso.claes@gmail.com [Departement of Radiology, Pediatric and Thoracic Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Clapuyt, Philippe, E-mail: philippe.clapuyt@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Menten, Renaud, E-mail: renaud.menten@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Michoux, Nicolas, E-mail: nicolas.michoux@uclouvain.be [Departement of Radiology, Institut de Recherche Expérimentale et Clinique, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium); Dumitriu, Dana, E-mail: dana.dumitriu@uclouvain.be [Departement of Radiology, Pediatric Radiology Unit, Université Catholique de Louvain, Avenue Hippocrate 10, 1200, Brussels (Belgium)

    2017-03-15

    Highlights: • Prospective comparison between chest X-ray and thoracic ultrasound for the detection of pneumonia in children. • Good correlation between X-ray and ultrasound for the detection and localization of pneumonia. • Thoracic ultrasound has an excellent negative predictive value (99%) for pediatric pneumonia. • Ultrasound may be used as a non-ionizing alternative to X-ray to exclude pneumonia in children. - Abstract: Objective: The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. Materials and methods: From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. Results: 143 children (mean age 3 years; limits between 8 days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4 mm; for consolidations visible on both techniques the mean size was 26 mm (p < 0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Conclusion: Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus

  19. Performance of chest ultrasound in pediatric pneumonia

    International Nuclear Information System (INIS)

    Claes, Anne-Sophie; Clapuyt, Philippe; Menten, Renaud; Michoux, Nicolas; Dumitriu, Dana

    2017-01-01

    Highlights: • Prospective comparison between chest X-ray and thoracic ultrasound for the detection of pneumonia in children. • Good correlation between X-ray and ultrasound for the detection and localization of pneumonia. • Thoracic ultrasound has an excellent negative predictive value (99%) for pediatric pneumonia. • Ultrasound may be used as a non-ionizing alternative to X-ray to exclude pneumonia in children. - Abstract: Objective: The objective of this study was to evaluate the performance of ultrasound in detecting lung consolidation in children suspected of pneumonia, in comparison to the current gold standard, chest X-rays. Materials and methods: From September 2013 to June 2014, a monocentric prospective study was performed on all children between 0 and 16 years-old, referred for chest X-ray for suspected pneumonia. Each child was examined by chest ultrasound by an examiner blinded to the chest X-ray. The presence or absence of areas of consolidation, their number and location were noted for each technique. The size of the consolidations identified only on ultrasound was compared with that of consolidations visible on both techniques. Results: 143 children (mean age 3 years; limits between 8 days and 14 years) were included. Ultrasound detected at least one area of consolidation in 44 out of 45 patients with positive X-rays. Of the 59 areas of consolidation on X-ray, ultrasound identified 54. In the 8 patients with negative X-ray, ultrasound revealed 17 areas of consolidation. The mean size of consolidations visible only on ultrasound was 9.4 mm; for consolidations visible on both techniques the mean size was 26 mm (p < 0.0001). The sensitivity and specificity of ultrasound were calculated at 98% and 92%. PPV and NPV were 85% and 99%, respectively. Conclusion: Chest ultrasound is a fast, non-ionizing and feasible technique. With its high negative predictive value, it can replace X-rays in order to exclude lung consolidation in children, thus

  20. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Zagzebski, J. [University of Wisconsin (United States)

    2016-06-15

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  1. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    International Nuclear Information System (INIS)

    Zagzebski, J.

    2016-01-01

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) abdominal ultrasound imaging produces pictures ...

  3. Forward Scattering of Loaded and Unloaded Antennas

    DEFF Research Database (Denmark)

    Gustafsson, Mats; Andersen, Jørgen Bach; Kristensson, Gerhard

    2012-01-01

    Forward scattering of antennas is related to antenna performance via the forward-scattering sum rule. The forward-scattering sum rule is an integral identity that shows that a weighted integral of the extinction cross section over all spectrum is proportional to the static polarizability...... of the antenna structure. Here, the forward-scattering sum rule is experimentally verified for loaded, short-circuit, and open-circuit cylindrical dipole antennas. It is also shown that the absorption efficiency cannot be greater than 1/2 for reciprocal linearly polarized lossless matched antennas...... with a symmetric radiation pattern in the forward and backward directions....

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... imaging produces pictures of the internal organs and blood vessels located within a child's abdomen. A Doppler ultrasound study may be part of a child's abdominal ultrasound ...

  5. Comparison of ultrasound and ultrasound plus nerve stimulator guidance axillary plexus block

    International Nuclear Information System (INIS)

    Demirelli, G.; Baskan, S.; Karabeyoglu, I.; Aytac, I.; Omek, D.H.; Erdogmus, A.; Baydar, M.

    2017-01-01

    To evaluate the characteristics of axillary plexus blockade applied using ultrasound only and using ultrasound together with nerve stimulator in patients undergoing planned forearm, wrist or hand surgery. Methods: This randomised, prospective, double-blinded, single-centre study was conducted at Ankara Numune Training and Research Hospital, Ankara, Turkey, from November 2014 to August 2015, and comprised patients undergoing forearm, wrist or hand surgery. Participants were separated into 2 groups. In Group 1, the nerve roots required for the surgical site were located one by one and local anaesthetic was applied separately to each nerve for the block. In Group 2, the vascular nerve bundle was located under ultrasound guidance and a total block was achieved by administering all the local anaesthetic within the nerve sheath. In the operating room, standard monitorisation was applied. Following preparation of the skin, the axillary region nerve roots and branches and vascular structures were observed by examination with a high-frequency ultrasound probe. In both groups, a 22-gauge, 5cm block needle was entered to the axillary region with visualisation of the whole needle on ultrasound and 20ml local anaesthetic of 0.5% bupivacaine was injected. SPSS 19 was used for data analysis. Results: Of the 60 participants, there were 30(50%) in each group. The mean age was 39.1+-15 years in the group 1 which was the ultrasound nerve stimulation group, and 41.5+-14.3 years in group 2. The duration of the procedure was longer in group I than in group 2 (p<0.05). Patient satisfaction values during the procedure were higher in group 2(p<0.05). In the ulnar sensory examination, the values of the patients in group 1 were higher at 10, 15, 20 and 25 minutes (p<0.05). In the median, radial and ulnar motor examination, the values of the patients in group 1were higher at 15 and 20 minutes (p<0.05). Conclusion: Brachial plexus blockade via axillary approach guided by ultrasound offered

  6. Splenic abnormalities: a comparative review of ultrasound, microbubble-enhanced ultrasound and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Peddu, P.; Shah, M.; Sidhu, P.S. E-mail: paul.sidhu@kingsch.nhs.uk

    2004-09-01

    The ultrasound appearances of abnormalities of the spleen are reviewed and images compared with computed tomography. Focal lesions, both benign and malignant, trauma, infarction and congenital abnormalities are presented. The use of microbubble ultrasound contrast media as an aid to identifying and characterizing abnormalities is discussed.

  7. Ultrasound

    Science.gov (United States)

    ... completed. Young children may need additional preparation. When scheduling an ultrasound for yourself or your child, ask ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  8. Portable Ultrasound Imaging

    DEFF Research Database (Denmark)

    di Ianni, Tommaso

    This PhD project investigates hardware strategies and imaging methods for hand-held ultrasound systems. The overall idea is to use a wireless ultrasound probe linked to general-purpose mobile devices for the processing and visualization. The approach has the potential to reduce the upfront costs...... beamforming strategies are simulated from a system-level perspective. The quality of the B-mode image is evaluated and the minimum specifications are derived for the design of a portable probe with integrated electronics in-handle. The system is based on a synthetic aperture sequential beamforming approach...... that allows to significantly reduce the data rate between the probe and processing unit. The second part investigates the feasibility of vector flow imaging in a hand-held ultrasound system. Vector flow imaging overcomes the limitations of conventional imaging methods in terms of flow angle compensation...

  9. Frequency and number of ultrasound lung rockets (B-lines) using a regionally based lung ultrasound examination named vet BLUE (veterinary bedside lung ultrasound exam) in dogs with radiographically normal lung findings.

    Science.gov (United States)

    Lisciandro, Gregory R; Fosgate, Geoffrey T; Fulton, Robert M

    2014-01-01

    Lung ultrasound is superior to lung auscultation and supine chest radiography for many respiratory conditions in human patients. Ultrasound diagnoses are based on easily learned patterns of sonographic findings and artifacts in standardized images. By applying the wet lung (ultrasound lung rockets or B-lines, representing interstitial edema) versus dry lung (A-lines with a glide sign) concept many respiratory conditions can be diagnosed or excluded. The ultrasound probe can be used as a visual stethoscope for the evaluation of human lungs because dry artifacts (A-lines with a glide sign) predominate over wet artifacts (ultrasound lung rockets or B-lines). However, the frequency and number of wet lung ultrasound artifacts in dogs with radiographically normal lungs is unknown. Thus, the primary objective was to determine the baseline frequency and number of ultrasound lung rockets in dogs without clinical signs of respiratory disease and with radiographically normal lung findings using an 8-view novel regionally based lung ultrasound examination called Vet BLUE. Frequency of ultrasound lung rockets were statistically compared based on signalment, body condition score, investigator, and reasons for radiography. Ten left-sided heart failure dogs were similarly enrolled. Overall frequency of ultrasound lung rockets was 11% (95% confidence interval, 6-19%) in dogs without respiratory disease versus 100% (95% confidence interval, 74-100%) in those with left-sided heart failure. The low frequency and number of ultrasound lung rockets observed in dogs without respiratory disease and with radiographically normal lungs suggests that Vet BLUE will be clinically useful for the identification of canine respiratory conditions. © 2014 American College of Veterinary Radiology.

  10. Ultrasound: Bladder (For Parents)

    Science.gov (United States)

    ... If You Have Questions Print en español Ultrasonido: vejiga What It Is A bladder ultrasound is a safe and painless test that ... Exam: Voiding Cystourethrogram (VCUG) Ultrasound: Renal (Kidneys, Ureters, Bladder) Urinary ... only. For specific medical advice, diagnoses, and treatment, consult your doctor. © 1995- The Nemours Foundation. All ...

  11. [Ultrasound-guided peripheral catheterization].

    Science.gov (United States)

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  12. Measurement of tissue viscoelasticity with ultrasound

    Science.gov (United States)

    Greenleaf, J. F.; Alizad, A.

    2017-02-01

    Tissue properties such as elasticity and viscosity have been shown to be related to such tissue conditions as contraction, edema, fibrosis, and fat content among others. Magnetic Resonance Elastography has shown outstanding ability to measure the elasticity and in some cases the viscosity of tissues, especially in the liver, providing the ability to stage fibrotic liver disease similarly to biopsy. We discuss ultrasound methods of measuring elasticity and viscosity in tissues. Many of these methods are becoming widely available in the extant ultrasound machines distributed throughout the world. Some of the methods to be discussed are in the developmental stage. The advantages of the ultrasound methods are that the imaging instruments are widely available and that many of the viscoelastic measurements can be made during a short addition to the normal ultrasound examination time. In addition, the measurements can be made by ultrasound repetitively and quickly allowing evaluation of dynamic physiologic function in circumstances such as muscle contraction or artery relaxation. Measurement of viscoelastic tissue mechanical properties will become a consistent part of clinical ultrasound examinations in our opinion.

  13. Mapping intravascular ultrasound controversies in interventional cardiology practice.

    Directory of Open Access Journals (Sweden)

    David Maresca

    Full Text Available Intravascular ultrasound is a catheter-based imaging modality that was developed to investigate the condition of coronary arteries and assess the vulnerability of coronary atherosclerotic plaques in particular. Since its introduction in the clinic 20 years ago, use of intravascular ultrasound innovation has been relatively limited. Intravascular ultrasound remains a niche technology; its clinical practice did not vastly expand, except in Japan, where intravascular ultrasound is an appraised tool for guiding percutaneous coronary interventions. In this qualitative research study, we follow scholarship on the sociology of innovation in exploring both the current adoption practices and perspectives on the future of intravascular ultrasound. We conducted a survey of biomedical experts with experience in the technology, the practice, and the commercialization of intravascular ultrasound. The collected information enabled us to map intravascular ultrasound controversies as well as to outline the dynamics of the international network of experts that generates intravascular ultrasound innovations and uses intravascular ultrasound technologies. While the technology is praised for its capacity to measure coronary atherosclerotic plaque morphology and is steadily used in clinical research, the lack of demonstrated benefits of intravascular ultrasound guided coronary interventions emerges as the strongest factor that prevents its expansion. Furthermore, most of the controversies identified were external to intravascular ultrasound technology itself, meaning that decision making at the industrial, financial and regulatory levels are likely to determine the future of intravascular ultrasound. In light of opinions from the responding experts', a wider adoption of intravascular ultrasound as a stand-alone imaging modality seems rather uncertain, but the appeal for this technology may be renewed by improving image quality and through combination with

  14. [Role of ultrasound in elective abortions].

    Science.gov (United States)

    Wylomanski, S; Winer, N

    2016-12-01

    Ultrasound plays a fundamental role in the management of elective abortions. Although it can improve the quality of post-abortion care, it must not be an obstacle to abortion access. We thus studied the role of ultrasound in pregnancy dating and possible alternatives and analyzed the literature to determine the role of ultrasound in post-abortion follow-up. During an ultrasound scan, the date of conception is estimated by measurement of the crown-rump length (CRL), defined by Robinson, or of the biparietal diameter (BPD), as defined by the French Center for Fetal Ultrasound (CFEF) after 11 weeks of gestation (Robinson and CFEF curves) (grade B). Updated curves have been developed in the INTERGROWTH study. In the context of abortion, the literature recommends the application of a safety margin of 5 days, especially when the CRL and/or BPD measurement indicates a term close to 14 weeks (that is equal or below 80 and 27mm, respectively) (best practice agreement). Accordingly, with the ultrasound measurement reliable to±5 days when its performance meets the relevant criteria, an abortion can take place when the CRL measurement is less than 90mm or the BPD less than 30mm (INTERGROWTH curves) (best practice agreement). While a dating ultrasound should be encouraged, its absence is not an obstacle to scheduling an abortion for women who report that they know the date of their last menstrual period and/or of the at-risk sexual relations and for whom a clinical examination by a healthcare professional is possible (best practice agreement). In cases of intrauterine pregnancy of uncertain viability or of a pregnancy of unknown location, without any particular symptoms, the patient must be able to have a transvaginal ultrasound to increase the precision of the diagnosis (grade B). Various reviews of the literature on post-abortion follow-up indicate that the routine use of ultrasound during instrumental abortions should be avoided (best practice agreement). If it becomes

  15. Studies of nonlinear ultrasound propagation: safety considerations in the use of ultrasound for medical diagnosis - nonlinear propagation

    International Nuclear Information System (INIS)

    Egerton, B.; Barnett, S.; Vella, G.

    1994-01-01

    Diagnostic ultrasound is an established imaging modality without any documented harmful effects. New developments such as pulsed Doppler and intracavity investigations may result in increases in ultrasound exposures which could cause harm. Thermal mechanisms and cavitation may become relevant sources of bioeffects. The preliminary study described here investigates the distribution and amplitude of harmonics generated through nonlinear propagation of ultrasound in water. Knowledge of harmonic attenuation will help predict sites of enhanced heating and enable accurate modelling of clinical situations. This presentation is concerned with thermal safety guidelines, their relationship to a typical ultrasound beam profile for a single, medium focussed, transducer operating in water and possible sites of enhanced heating due to nonlinear propagation effects. Measurements were made of the amplitudes of the harmonics generated by the nonlinear propagation of ultrasound in water. The amplitudes of the harmonics were detected up to frequencies of 35 MHz and displayed using Fast Fourier Transform facilities within the oscilloscope. The nonlinearity parameter of the ultrasonic waveforms has been identified as an important factor in thermal effects of ultrasound interactions. The appearance of nonlinear distortion is shown to be dependant on the peak compressional pressure and distance from the ultrasound source. 20 refs., 2 figs

  16. Vacuum mammotomy under ultrasound guidance

    International Nuclear Information System (INIS)

    Luczynska, E.; Kocurek, A.; Pawlik, T.; Aniol, J.; Herman, K.; Skotnicki, P.

    2007-01-01

    Breast ultrasound is a non-invasive method of breast examination. You can use it also for fine needle biopsy, core needle biopsy, vacuum mammotomy and for placing the '' wire '' before open surgical biopsy. 106 patients (105 women and 1 man) aged 20-71 years (mean age 46.9) were treated in Cancer Institute in Cracow by vacuum mammotomy under ultrasound guidance. The lesions found in ultrasonography were divided into three groups: benign lesions (BI RADS II), ambiguous lesions (BI RADS 0, III and IVa), and suspicious lesions (BI RADS IV B, IV C and V). Then lesions were qualified to vacuum mammotomy. According to USG, fibroadenoma or '' fibroadenoma-like '' lesions were found in 75 women, in 6 women complicated cysts, in 6 women cyst with dense fluid (to differentiate with FA), and in 19 patients undefined lesions. Fibroadenoma was confirmed in histopathology in 74% patients among patients with fibroadenoma or '' fibroadenoma-like '' lesions in ultrasound (in others also benign lesions were found). Among lesions undefined after ultrasound examination (total 27 patients) cancer was confirmed in 6 % (DCIS and IDC). In 6 patients with complicated cysts in ultrasound examination, histopathology confirmed fibroadenoma in 4 women, an intraductal lesion in 1 woman and inflamatory process in 1 woman. Also in 6 women with a dense cyst or fibroadenoma seen in ultrasound, histopathology confirmed fibroadenoma in 3 women and fibrosclerosis in 3 women. Any breast lesions undefined or suspicious after ultrasound examination should be verified. The method of verification or kind of operation of the whole lesion (vacuum mammotomy or '' wire '') depends on many factors, for example: lesion localization; lesion size; BI RADS category. (author)

  17. Spatiotemporal matrix image formation for programmable ultrasound scanners

    Science.gov (United States)

    Berthon, Beatrice; Morichau-Beauchant, Pierre; Porée, Jonathan; Garofalakis, Anikitos; Tavitian, Bertrand; Tanter, Mickael; Provost, Jean

    2018-02-01

    As programmable ultrasound scanners become more common in research laboratories, it is increasingly important to develop robust software-based image formation algorithms that can be obtained in a straightforward fashion for different types of probes and sequences with a small risk of error during implementation. In this work, we argue that as the computational power keeps increasing, it is becoming practical to directly implement an approximation to the matrix operator linking reflector point targets to the corresponding radiofrequency signals via thoroughly validated and widely available simulations software. Once such a spatiotemporal forward-problem matrix is constructed, standard and thus highly optimized inversion procedures can be leveraged to achieve very high quality images in real time. Specifically, we show that spatiotemporal matrix image formation produces images of similar or enhanced quality when compared against standard delay-and-sum approaches in phantoms and in vivo, and show that this approach can be used to form images even when using non-conventional probe designs for which adapted image formation algorithms are not readily available.

  18. Another look at ultrasound and magnetic resonance imaging for diagnosis of placenta accreta.

    Science.gov (United States)

    Budorick, Nancy E; Figueroa, Reinaldo; Vizcarra, Michael; Shin, James

    2017-10-01

    To compare the ability of magnetic resonance imaging (MRI) and ultrasound (US) in the diagnosis of placenta accreta, to examine the success of various sonographic and MRI features to correctly predict invasive placenta, and to define a specific role for MRI in placenta accreta. After Institutional Review Board approval, a blinded retrospective review was undertaken of US and MRI findings from 45 patients who had an obstetrical US and placental MRI between August 2006 and January 2012. Correlation with clinical history and pathologic findings was performed. US and MRI had similar sensitivity, specificity and positive and negative predictive values for placenta accreta. The best predictors of invasion by US were loss of the myometrial mantle, increased intraplacental vascularity and loss of the bladder wall echogenicity. The best predictors of invasion by MRI were loss of retroplacental myometrial mantle, a heterogeneous placenta, and intraplacental hemorrhage. Body mass index (BMI) did not affect the ability to make a diagnosis by either US or MRI. MRI proved effective in better evaluation of a posterior placenta with suspicion of placenta accreta. There was modality disagreement in 11 of 45 cases and MRI was correct in 9 of these 11 cases, all true negative (TN) cases. MRI should be considered in any case with posterior placenta previa and suspicion of accreta, in any case with clinical suspicion for accreta and discordant US findings, and in any case in which percreta is suspected.

  19. Checkpoint-based forward recovery using lookahead execution and rollback validation in parallel and distributed systems. Ph.D. Thesis, 1992

    Science.gov (United States)

    Long, Junsheng

    1994-01-01

    This thesis studies a forward recovery strategy using checkpointing and optimistic execution in parallel and distributed systems. The approach uses replicated tasks executing on different processors for forwared recovery and checkpoint comparison for error detection. To reduce overall redundancy, this approach employs a lower static redundancy in the common error-free situation to detect error than the standard N Module Redundancy scheme (NMR) does to mask off errors. For the rare occurrence of an error, this approach uses some extra redundancy for recovery. To reduce the run-time recovery overhead, look-ahead processes are used to advance computation speculatively and a rollback process is used to produce a diagnosis for correct look-ahead processes without rollback of the whole system. Both analytical and experimental evaluation have shown that this strategy can provide a nearly error-free execution time even under faults with a lower average redundancy than NMR.

  20. Forward Osmosis in Wastewater Treatment Processes.

    Science.gov (United States)

    Korenak, Jasmina; Basu, Subhankar; Balakrishnan, Malini; Hélix-Nielsen, Claus; Petrinic, Irena

    2017-01-01

    In recent years, membrane technology has been widely used in wastewater treatment and water purification. Membrane technology is simple to operate and produces very high quality water for human consumption and industrial purposes. One of the promising technologies for water and wastewater treatment is the application of forward osmosis. Essentially, forward osmosis is a process in which water is driven through a semipermeable membrane from a feed solution to a draw solution due to the osmotic pressure gradient across the membrane. The immediate advantage over existing pressure driven membrane technologies is that the forward osmosis process per se eliminates the need for operation with high hydraulic pressure and forward osmosis has low fouling tendency. Hence, it provides an opportunity for saving energy and membrane replacement cost. However, there are many limitations that still need to be addressed. Here we briefly review some of the applications within water purification and new developments in forward osmosis membrane fabrication.

  1. [Assessment of the sonographer's knowledge on the second trimester ultrasound recommendations of the National Technical Committee of Ultrasound].

    Science.gov (United States)

    Matar, M; Picone, O; Dalmon, C; Ayoubi, J-M

    2013-09-01

    To evaluate the sonographers' knowledge of the National Technical Committee of Ultrasound's recommendations concerning second trimester ultrasound. Anonymous questionnaire was sent by e-mails containing 25 questions about demographic elements, the practice of second trimester ultrasound and the recommendations of the National Technical Committee of Ultrasound about second trimester ultrasound. Six hundred and eighty-four responses were obtained. Six hundred and fifty-three upon 684 (95%) of respondents practice second trimester ultrasound and 635 upon 653 (97%) know about the existence of the report of the National Technical Committee of Ultrasound. The rates of correct answers concerning recommended biometrical images vary between 97% for the biparietal diameter and head circumference, 98% for abdominal circumference and 100% for the femur length. While for morphological images, rates vary between 52% and 100%. A subgroup analysis (whether the respondents have already read the recommendations or not) showed that those who had read the recommendations have significantly better results than those who did not. Those who have already read the recommendations have better knowledge and global knowledge can be improved. National recommendations serve to promote a policy of quality assurance of ultrasound and may be used in medicolegal issues. The societies that make recommendations should more diffuse their work and practitioners should make effort to pursue the continuing medical education and to implement the recommendations. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  2. Alternative Ultrasound Gel for a Sustainable Ultrasound Program: Application of Human Centered Design.

    Directory of Open Access Journals (Sweden)

    Margaret Salmon

    Full Text Available This paper describes design of a low cost, ultrasound gel from local products applying aspects of Human Centered Design methodology. A multidisciplinary team worked with clinicians who use ultrasound where commercial gel is cost prohibitive and scarce. The team followed the format outlined in the Ideo Took Kit. Research began by defining the challenge "how to create locally available alternative ultrasound gel for a low-resourced environment? The "End-Users," were identified as clinicians who use ultrasound in Democratic Republic of the Congo and Ethiopia. An expert group was identified and queried for possible alternatives to commercial gel. Responses included shampoo, oils, water and cornstarch. Cornstarch, while a reasonable solution, was either not available or too expensive. We then sought deeper knowledge of locally sources materials from local experts, market vendors, to develop a similar product. Suggested solutions gleaned from these interviews were collected and used to create ultrasound gel accounting for cost, image quality, manufacturing capability. Initial prototypes used cassava root flour from Great Lakes Region (DRC, Rwanda, Uganda, Tanzania and West Africa, and bula from Ethiopia. Prototypes were tested in the field and resulting images evaluated by our user group. A final prototype was then selected. Cassava and bula at a 32 part water, 8 part flour and 4 part salt, heated, mixed then cooled was the product design of choice.

  3. Alternative Ultrasound Gel for a Sustainable Ultrasound Program: Application of Human Centered Design.

    Science.gov (United States)

    Salmon, Margaret; Salmon, Christian; Bissinger, Alexa; Muller, Mundenga Mutendi; Gebreyesus, Alegnta; Geremew, Haimanot; Wendel, Sarah K; Wendell, Sarah; Azaza, Aklilu; Salumu, Maurice; Benfield, Nerys

    2015-01-01

    This paper describes design of a low cost, ultrasound gel from local products applying aspects of Human Centered Design methodology. A multidisciplinary team worked with clinicians who use ultrasound where commercial gel is cost prohibitive and scarce. The team followed the format outlined in the Ideo Took Kit. Research began by defining the challenge "how to create locally available alternative ultrasound gel for a low-resourced environment? The "End-Users," were identified as clinicians who use ultrasound in Democratic Republic of the Congo and Ethiopia. An expert group was identified and queried for possible alternatives to commercial gel. Responses included shampoo, oils, water and cornstarch. Cornstarch, while a reasonable solution, was either not available or too expensive. We then sought deeper knowledge of locally sources materials from local experts, market vendors, to develop a similar product. Suggested solutions gleaned from these interviews were collected and used to create ultrasound gel accounting for cost, image quality, manufacturing capability. Initial prototypes used cassava root flour from Great Lakes Region (DRC, Rwanda, Uganda, Tanzania) and West Africa, and bula from Ethiopia. Prototypes were tested in the field and resulting images evaluated by our user group. A final prototype was then selected. Cassava and bula at a 32 part water, 8 part flour and 4 part salt, heated, mixed then cooled was the product design of choice.

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on x-ray images. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  5. Morphofunctional state of the heart in children and adolescents who suffered due to Chernobyl accident (findings of ultrasound studies)

    International Nuclear Information System (INIS)

    Kostenko, T.O.

    1998-01-01

    Great incidence of intracardiac hemodynamic disorders in children and adolescents evacuated from the contaminated zone (mainly in those who resided in Zhytomir region for a long period) testifies to the possible negative effect of ionizing radiation on cardiovascular system. A rehabilitation treatment scheme for such children and adolescents should include cardiotonic and vegetotropic remedies

  6. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjonction: Comparison of radiographic, ultrasound and MRI findings.

    Science.gov (United States)

    Faruch Bilfeld, Marie; Lapègue, Franck; Chiavassa Gandois, Hélène; Bayol, Marie Aurélie; Bonnevialle, Nicolas; Sans, Nicolas

    2017-02-01

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p acromioclavicular injury. • Ultrasound is appropriate for acute acromioclavicular trauma due to its accessibility. • Ultrasound contributes to the diagnostic work-up of acute lesions of the coracoclavicular ligaments. • Ultrasound is appropriate in patients likely to benefit from surgical treatment. • Ultrasound could be a supplement to standard radiography in acute acromioclavicular trauma.

  7. Role of spinal ultrasound in diagnosis of meningitis in infants younger than 6 months

    International Nuclear Information System (INIS)

    Nepal, Pankaj; Sodhi, Kushaljit Singh; Saxena, Akshay Kumar; Bhatia, Anmol; Singhi, Sunit; Khandelwal, Niranjan

    2015-01-01

    Highlights: •This was a prospective study to evaluate role of spinal ultrasound (US) in 60 infants (<6 months of age) with clinically suspected meningitis. •On ultrasound examination, we evaluated echogenicity and /or trabeculations in the posterior subarachnoid space and spinal cord pulsations. •Results of spinal US were evaluated in correlation with cerebrospinal fluid analysis. •Results of our study show presence of echogenicity/trabeculations in posterior subarachnoid space or abnormal pulsations of spinal cord and nerve roots are significantly associated with meningitis with a high specificity and positive predictive value in its diagnosis. •Spinal ultrasound can be used as a radiation free imaging modality to detect meningitis. -- Abstract: Background: Spinal ultrasound (US) can detect changes in CSF echogenicity and decreased cord pulsations which reflect the inflammatory changes in meningitis. Till date, there is no published data about the prospective accuracy of spinal US in meningitis. Objective: To assess accuracy of spinal US in diagnosis of meningitis in infants younger than 6 months. Methods: This was an institute ethics committee approved prospective study carried out in infants less than 6 months of age with clinical suspicion of meningitis who presented to pediatric emergency unit. 60 infants each in study and control group were enrolled. US of thoraco-lumbar spine were performed prior to lumbar puncture in all cases. We looked for the presence of echogenicity or trabeculations in posterior subarachnoid space and for presence or absence of spinal cord and nerve root pulsations on real time ultrasound. The results of spinal US were evaluated in correlation with cerebrospinal fluid analysis. Follow up ultrasounds were done in infants who showed abnormal findings after the initiation of treatment and findings compared with initial results. Results: The study group comprised of 40 boys and 20 girls with mean age of 47.85 days. The control

  8. Role of spinal ultrasound in diagnosis of meningitis in infants younger than 6 months

    Energy Technology Data Exchange (ETDEWEB)

    Nepal, Pankaj, E-mail: pankaj-123@live.com [Department of Radiodiagnosis and Imaging, Sector-12, Chandigarh 160012 (India); Sodhi, Kushaljit Singh, E-mail: sodhiks@gmail.com [Department of Radiodiagnosis and Imaging, Sector-12, Chandigarh 160012 (India); Saxena, Akshay Kumar, E-mail: fatakshay@yahoo.com [Department of Radiodiagnosis and Imaging, Sector-12, Chandigarh 160012 (India); Bhatia, Anmol, E-mail: anmol_bhatia26@yahoo.co.in [Department of Radiodiagnosis and Imaging, Sector-12, Chandigarh 160012 (India); Singhi, Sunit, E-mail: sunit.singhi@gmail.com [Department of Pediatrics, Post Graduate Institute of Medical Education and Research, Sector-12, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Department of Radiodiagnosis and Imaging, Sector-12, Chandigarh 160012 (India)

    2015-03-15

    Highlights: •This was a prospective study to evaluate role of spinal ultrasound (US) in 60 infants (<6 months of age) with clinically suspected meningitis. •On ultrasound examination, we evaluated echogenicity and /or trabeculations in the posterior subarachnoid space and spinal cord pulsations. •Results of spinal US were evaluated in correlation with cerebrospinal fluid analysis. •Results of our study show presence of echogenicity/trabeculations in posterior subarachnoid space or abnormal pulsations of spinal cord and nerve roots are significantly associated with meningitis with a high specificity and positive predictive value in its diagnosis. •Spinal ultrasound can be used as a radiation free imaging modality to detect meningitis. -- Abstract: Background: Spinal ultrasound (US) can detect changes in CSF echogenicity and decreased cord pulsations which reflect the inflammatory changes in meningitis. Till date, there is no published data about the prospective accuracy of spinal US in meningitis. Objective: To assess accuracy of spinal US in diagnosis of meningitis in infants younger than 6 months. Methods: This was an institute ethics committee approved prospective study carried out in infants less than 6 months of age with clinical suspicion of meningitis who presented to pediatric emergency unit. 60 infants each in study and control group were enrolled. US of thoraco-lumbar spine were performed prior to lumbar puncture in all cases. We looked for the presence of echogenicity or trabeculations in posterior subarachnoid space and for presence or absence of spinal cord and nerve root pulsations on real time ultrasound. The results of spinal US were evaluated in correlation with cerebrospinal fluid analysis. Follow up ultrasounds were done in infants who showed abnormal findings after the initiation of treatment and findings compared with initial results. Results: The study group comprised of 40 boys and 20 girls with mean age of 47.85 days. The control

  9. Additional findings at preoperative breast MRI: the value of second-look digital breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Clauser, Paola; Pancot, Martina; Girometti, Rossano; Bazzocchi, Massimo; Zuiani, Chiara [University of Udine, Azienda Ospedaliero-Universitaria, ' ' S.Maria della Misericordia' ' , Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, Udine (Italy); Carbonaro, Luca A. [IRCCS Policlinico San Donato, Unit of Radiology, Milan (Italy); Sardanelli, Francesco [IRCCS Policlinico San Donato, Unit of Radiology, Milan (Italy); Universita degli Studi di Milano, Department of Biomedical Sciences of Health, Milan (Italy)

    2015-10-15

    To evaluate second-look digital breast tomosynthesis (SL-DBT) for additional findings (AFs) at preoperative MRI compared with second-look ultrasound (SL-US). We included 135 patients with breast cancer who underwent digital mammography (DM), DBT, US, and MRI at two centres. MR images were retrospectively evaluated to find AFs, described as focus, mass, or non-mass; ≤10 mm or >10 mm in size; BI-RADS 3, 4, or 5. DM and DBT exams were reviewed looking for MRI AFs; data on SL-US were collected. Reference standard was histopathology or ≥12-month negative follow-up. Fisher exact test and McNemar test were used. Eighty-four AFs were detected in 53/135 patients (39 %, 95 %CI 31-48 %). A correlate was found for 44/84 (52 %, 95 %CI 41-63 %) at SL-US, for 20/84 (24 %, 95 %CI 11-28 %) at SL-DM, for 42/84 (50 %, 95 %CI 39-61 %) at SL-DBT, for 63/84 (75 %, 95 %CI 64-84 %) at SL-DBT, and/or SL-US, the last rate being higher than for SL-US only, overall (p < 0.001), for mass or non-mass, ≤ or >10 mm, BI-RADS 4 or 5, or malignant lesions (p < 0.031). Of 21 AFs occult at both SLs, 17 were malignant (81 %, 95 %CI 58-94 %). When adding SL-DBT to SL-US, AFs detection increased from 52 % to 75 %. MR-guided biopsy is needed for the remaining 25 %. (orig.)

  10. Forward physics with CMS

    CERN Document Server

    Grothe, Monika

    2008-01-01

    Forward physics with CMS at the LHC covers a wide range of physics subjects, including very low-x_Bj QCD, underlying event and multiple interactions characteristics, gamma-mediated processes, shower development at the energy scale of primary cosmic ray interactions with the atmosphere, diffraction in the presence of a hard scale and even MSSM Higgs discovery in central exclusive production. Selected feasibility studies to illustrate the forward physics potential of CMS are presented.

  11. Heat transfer enhancement using 2MHz ultrasound.

    Science.gov (United States)

    Bulliard-Sauret, Odin; Ferrouillat, Sebastien; Vignal, Laure; Memponteil, Alain; Gondrexon, Nicolas

    2017-11-01

    The present work focuses on possible heat transfer enhancement from a heating plate towards tap water in forced convection by means of 2MHz ultrasound. The thermal approach allows to observe the increase of local convective heat transfer coefficients in the presence of ultrasound and to deduce a correlation between ultrasound power and Nusselt number. Heat transfer coefficient under ultrasound remains constant while heat transfer coefficient under silent conditions increases with Reynolds number from 900 up to 5000. Therefore, heat transfer enhancement factor ranges from 25% up to 90% for the same energy conditions (supplied ultrasonic power=110W and supplied thermal power=450W). In the same time cavitational activity due to 2MHz ultrasound emission was characterized from mechanical and chemical viewpoints without significant results. At least, Particle Image Velocimetry (PIV) measurements have been performed in order to investigate hydrodynamic modifications due to the presence of 2MHz ultrasound. It was therefore possible to propose a better understanding of heat transfer enhancement mechanism with high frequency ultrasound. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Ultrasound

    Science.gov (United States)

    ... reflect off body structures. A computer receives the waves and uses them to create a picture. Unlike with an x-ray or CT scan, this test does not use ionizing radiation. The test is done in the ultrasound ...

  13. Mechanics of ultrasound elastography

    Science.gov (United States)

    Li, Guo-Yang

    2017-01-01

    Ultrasound elastography enables in vivo measurement of the mechanical properties of living soft tissues in a non-destructive and non-invasive manner and has attracted considerable interest for clinical use in recent years. Continuum mechanics plays an essential role in understanding and improving ultrasound-based elastography methods and is the main focus of this review. In particular, the mechanics theories involved in both static and dynamic elastography methods are surveyed. They may help understand the challenges in and opportunities for the practical applications of various ultrasound elastography methods to characterize the linear elastic, viscoelastic, anisotropic elastic and hyperelastic properties of both bulk and thin-walled soft materials, especially the in vivo characterization of biological soft tissues. PMID:28413350

  14. Relative ultrasound energy measurement circuit

    OpenAIRE

    Gustafsson, E.Martin I.; Johansson, Jonny; Delsing, Jerker

    2005-01-01

    A relative ultrasound energy estimation circuit has been designed in a standard 0.35-μm CMOS process, to be a part of a thumb size internet connected wireless ultrasound measurement system. This circuit measures the relative energy between received ultrasound pulses, and presents an output signal that is linear to the received energy. Post-layout simulations indicate 7 bit linearity for 500 mV input signals, 5 μsec startup and stop times, 2.6 mW power consumption during active state. The acti...

  15. Impact of ultrasound video transfer on the practice of ultrasound

    Science.gov (United States)

    Duerinckx, Andre J.; Hayrapetian, Alek S.; Grant, Edward G.; Valentino, Daniel J.; Rahbar, Darius; Kiszonas, Mike; Franco, Ricky; Melany, Michelle; Narin, Sherelle L.; Ragavendra, Nagesh

    1996-05-01

    Sonography can be highly dependent on real-time imaging and as such is highly physician intensive. Such situations arise mostly during complicated ultrasound radiology studies or echocardiology examinations. Under those circumstances it would be of benefit to transmit real-time images beyond the immediate area of the ultrasound laboratory when a physician is not on location. We undertook this study to determine if both static and dynamic image transfer to remote locations might be accomplished using an ultrafast ATM network and PACS. Image management of the local image files was performed by a commercial PACS from AGFA corporation. The local network was Ethernet based, and the global network was based on Asynchronous Transfer Mode (ATM, rates up to 100 Mbits/sec). Real-time image transfer involved two teaching hospitals, one of which had 2 separate ultrasound facilities. Radiologists consulted with technologists via telephone while the examinations were being performed. The applications of ATM network providing real time video for ultrasound imaging in a clinical environment and its potential impact on health delivery and clinical teaching. This technology increased technologist and physician productivity due to the elimination of commute time for physicians and waiting time for technologists and patients. Physician confidence in diagnosis increased compared to reviewing static images alone. This system provided instant access for radiologists to real-time scans from remote sites. Image quality and frame rate were equivalent to the original. The system increased productivity by allowing physicians to monitor studies at multiple sites simultaneously.

  16. Pulse Compression Techniques for Laser Generated Ultrasound

    Science.gov (United States)

    Anastasi, R. F.; Madaras, E. I.

    1999-01-01

    Laser generated ultrasound for nondestructive evaluation has an optical power density limit due to rapid high heating that causes material damage. This damage threshold limits the generated ultrasound amplitude, which impacts nondestructive evaluation inspection capability. To increase ultrasound signal levels and improve the ultrasound signal-to-noise ratio without exceeding laser power limitations, it is possible to use pulse compression techniques. The approach illustrated here uses a 150mW laser-diode modulated with a pseudo-random sequence and signal correlation. Results demonstrate the successful generation of ultrasonic bulk waves in aluminum and graphite-epoxy composite materials using a modulated low-power laser diode and illustrate ultrasound bandwidth control.

  17. The ALICE forward multiplicity detector

    DEFF Research Database (Denmark)

    Holm Christensen, Christian; Gulbrandsen, Kristjan; Sogaard, Carsten

    2007-01-01

    The ALICE Forward Multiplicity Detector (FMD) is a silicon strip detector with 51,200 strips arranged in 5 rings, covering the range $-3.4......The ALICE Forward Multiplicity Detector (FMD) is a silicon strip detector with 51,200 strips arranged in 5 rings, covering the range $-3.4...

  18. Ultrasound-Assisted Hot Air Drying of Foods

    Science.gov (United States)

    Mulet, Antonio; Cárcel, Juan Andrés; García-Pérez, José Vicente; Riera, Enrique

    This chapter deals with the application of power ultrasound, also named high-intensity ultrasound, in the hot air drying of foods. The aim of ultrasound-assisted drying is to overcome some of the limitations of traditional convective drying systems, especially by increasing drying rate without reducing quality attributes. The effects of ultrasound on drying rate are responsible for some of the phenomena produced in the internal and/or external resistance to mass transfer.

  19. What is the complementary role of ultrasound evaluation in the diagnosis of acute appendicitis after CT?

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Lee, Kwanseop [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of)], E-mail: kwanseop@hallym.or.kr; Kim, Min-Jeong; Yoon, Hoi Soo; Jeon, Eui Yong; Koh, Sung Hye [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Min, Kwangseon [Department of Pathology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Choi, Dongil [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (Korea, Republic of)

    2010-04-15

    The objective of our study was to estimate the complementary role of ultrasound evaluation in the diagnosis of acute appendicitis after abdominoplevic CT. A total of 104 patients initially underwent abdominopelvic CT before appendix US due to acute abdominal pain. All CT examinations were evaluated retrospectively for the presence of acute appendicitis. The findings of appendix on CT were classified into five categories (definite appendicitis, probably appendicitis, equivocal CT findings for diagnosis of appendicitis, probably not appendicitis, and normal looking appendix). Appendix US images and their radiologic reports were also evaluated retrospectively. Then, CT and US findings were correlated with clinical or pathologic diagnosis. Three all patients with definite appendicitis initially on CT again showed US findings of appendicitis. In the 32 patients of probably appendicitis on CT, US showed normal looking appendix in seven patients (21.8%, 7 of 32) who improved with medical treatment and discharged. In the 16 patients of equivocal CT findings for diagnosis of appendicitis, US showed appendicitis in seven patients (43.8%, 7 of 16) and normal looking appendix in nine patients. In the 12 patients of probably not appendicitis on CT, US showed acute appendicitis in two patients (16.7%, 2 of 12). In the 41 patients of normal looking appendix on CT, US showed acute appendicitis in five patients (12.2%, 5 of 41). US reevaluation enables us to avoid misdiagnosis of appendicitis on CT and improve diagnostic accuracy of acute appendicitis.

  20. Ultrasound elastography as an adjuvant to conventional ultrasound in the preoperative assessment of axillary lymph nodes in suspected breast cancer: A pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, K., E-mail: kathryn.taylor@addenbrookes.nhs.uk [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); O' Keeffe, S.; Britton, P.D.; Wallis, M.G. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Treece, G.M.; Housden, J. [Department of Engineering, University of Cambridge, Cambridge (United Kingdom); Parashar, D.; Bond, S. [Cambridge Cancer Trials Centre, Department of Oncology, University of Cambridge, Addenbrookes Hospital, Cambridge (United Kingdom); Cambridge Hub in Trials Methodology Research, MRC Biostatics Unit, University Forvie Site, Cambridge (United Kingdom); Sinnatamby, R. [Department of Radiology, Cambridge Breast Unit, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-11-15

    Aims: To compare the performance of ultrasound elastography with conventional ultrasound in the assessment of axillary lymph nodes in suspected breast cancer and whether ultrasound elastography as an adjunct to conventional ultrasound can increase the sensitivity of conventional ultrasound used alone. Materials and methods: Fifty symptomatic women with a sonographic suspicion for breast cancer underwent ultrasound elastography of the ipsilateral axilla concurrent with conventional ultrasound being performed as part of triple assessment. Elastograms were visually scored, strain measurements calculated and node area and perimeter measurements taken. Theoretical biopsy cut points were selected. The sensitivity, specificity, positive predictive value (PPV), and negative predictive values (NPV) were calculated and receiver operating characteristic (ROC) analysis was performed and compared for elastograms and conventional ultrasound images with surgical histology as the reference standard. Results: The mean age of the women was 57 years. Twenty-nine out of 50 of the nodes were histologically negative on surgical histology and 21 were positive. The sensitivity, specificity, PPV, and NPV for conventional ultrasound were 76, 78, 70, and 81%, respectively; 90, 86, 83, and 93%, respectively, for visual ultrasound elastography; and for strain scoring, 100, 48, 58 and 100%, respectively. There was no significant difference between any of the node measurements Conclusions: Initial experience with ultrasound elastography of axillary lymph nodes, showed that it is more sensitive than conventional ultrasound in detecting abnormal nodes in the axilla in cases of suspected breast cancer. The specificity remained acceptable and ultrasound elastography used as an adjunct to conventional ultrasound has the potential to improve the performance of conventional ultrasound alone.

  1. Interference-free ultrasound imaging during HIFU therapy, using software tools

    Science.gov (United States)

    Vaezy, Shahram (Inventor); Held, Robert (Inventor); Sikdar, Siddhartha (Inventor); Managuli, Ravi (Inventor); Zderic, Vesna (Inventor)

    2010-01-01

    Disclosed herein is a method for obtaining a composite interference-free ultrasound image when non-imaging ultrasound waves would otherwise interfere with ultrasound imaging. A conventional ultrasound imaging system is used to collect frames of ultrasound image data in the presence of non-imaging ultrasound waves, such as high-intensity focused ultrasound (HIFU). The frames are directed to a processor that analyzes the frames to identify portions of the frame that are interference-free. Interference-free portions of a plurality of different ultrasound image frames are combined to generate a single composite interference-free ultrasound image that is displayed to a user. In this approach, a frequency of the non-imaging ultrasound waves is offset relative to a frequency of the ultrasound imaging waves, such that the interference introduced by the non-imaging ultrasound waves appears in a different portion of the frames.

  2. Adaptive forward-inverse modeling of reservoir fluids away from wellbores; TOPICAL

    International Nuclear Information System (INIS)

    Ziagos, J P; Gelinas, R J; Doss, S K; Nelson, R G

    1999-01-01

    This Final Report contains the deliverables of the DeepLook Phase I project entitled, ''Adaptive Forward-Inverse Modeling of Reservoir Fluids Away from Wellbores''. The deliverables are: (i) a description of 2-D test problem results, analyses, and technical descriptions of the techniques used, (ii) a listing of program setup commands that construct and execute the codes for selected test problems (these commands are in mathematical terminology, which reinforces technical descriptions in the text), and (iii) an evaluation and recommendation regarding continuance of this project, including considerations of possible extensions to 3-D codes, additional technical scope, and budget for the out-years. The far-market objective in this project is to develop advanced technologies that can help locate and enhance the recovery of oil from heterogeneous rock formations. The specific technical objective in Phase I was to develop proof-of-concept of new forward and inverse (F-I) modeling techniques[Gelinas et al, 1998] that seek to enhance estimates (images) of formation permeability distributions and fluid motion away from wellbore volumes. This goes to the heart of improving industry's ability to jointly image reservoir permeability and flow predictions of trapped and recovered oil versus time. The estimation of formation permeability away from borehole measurements is an ''inverse'' problem. It is an inseparable part of modeling fluid flows throughout the reservoir in efforts to increase the efficiency of oil recovery at minimum cost. Classic issues of non-uniqueness, mathematical instability, noise effects, and inadequate numerical solution techniques have historically impeded progress in reservoir parameter estimations. Because information pertaining to fluid and rock properties is always sampled sparsely by wellbore measurements, a successful method for interpolating permeability and fluid data between the measurements must be: (i) physics-based, (ii) conditioned by signal

  3. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... be guided by ultrasound, are used to sample cells from organs for laboratory testing help detect the ... in which needles are used to extract sample cells from an abnormal area for laboratory testing. Ultrasound ...

  4. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... abdomen is a safe, noninvasive test that uses sound waves to produce a clear picture of the ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  5. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known ...

  6. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... children. Except for traumatic injury, appendicitis is the most common reason for emergency abdominal surgery. Ultrasound imaging ... of page How is the procedure performed? For most ultrasound exams, you will be positioned lying face- ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  9. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Children's (pediatric) ... uterus Abdominal ultrasound images can be used to help diagnose appendicitis in children. Except for traumatic injury, ...

  10. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  11. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes ...

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... safe and accurate placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound ... joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  13. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... kidneys bladder testicles ovaries uterus Abdominal ultrasound images can be used to help diagnose appendicitis in children. ...

  14. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... vomiting in young infants Because ultrasound provides real-time images, images that are renewed continuously, it also ...

  15. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound images can help ... tenderness, your child may feel pressure or minor pain from the procedure. If a Doppler ultrasound study ...

  16. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  17. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the best way to see if treatment is working or if a finding is stable or changed ...

  18. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... ultrasound. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  19. A clutter removal method for the Doppler ultrasound signal based on a nonlinear diffusion equation

    International Nuclear Information System (INIS)

    Li Peng; Xin Pengcheng; Bian Zhengzhong; Yu Gang

    2008-01-01

    Strong clutter components produced by stationary and slow-moving tissue structures render the lower frequency part of the spectrogram useless and degrade the accuracy of clinical ultrasound indices. An adaptive method based on the nonlinear forward-and-backward diffusion equation (FAB-DE) is proposed to remove strong clutter components from the contaminated Doppler signal. The clutter signal is extracted first by the FAB-DE accurately, in which the nonlinear diffusion coefficient function of the FAB-DE locally adjusts according to signal features and the diffusion adaptively switches between forward and backward mode. The present method has been validated by simulated and realistic pulse wave Doppler signals, and compared with the conventional high pass filter and the matching pursuit method. The simulation results, including spectrogram, mean velocity error, standard deviation of mean velocity and signal-to-clutter ratio of a decontaminated signal, demonstrate that the present FAB-DE method can remove clutter sufficiently and retain more low blood components simultaneously as compared with the other two methods. Results of the realistic Doppler blood signal, including spectrogram and low-frequency part of the spectrum, support the conclusion drawn from simulation cases

  20. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    Science.gov (United States)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will